WorldWideScience

Sample records for instrument ms predictions

  1. pDeep: Predicting MS/MS Spectra of Peptides with Deep Learning.

    Science.gov (United States)

    Zhou, Xie-Xuan; Zeng, Wen-Feng; Chi, Hao; Luo, Chunjie; Liu, Chao; Zhan, Jianfeng; He, Si-Min; Zhang, Zhifei

    2017-12-05

    In tandem mass spectrometry (MS/MS)-based proteomics, search engines rely on comparison between an experimental MS/MS spectrum and the theoretical spectra of the candidate peptides. Hence, accurate prediction of the theoretical spectra of peptides appears to be particularly important. Here, we present pDeep, a deep neural network-based model for the spectrum prediction of peptides. Using the bidirectional long short-term memory (BiLSTM), pDeep can predict higher-energy collisional dissociation, electron-transfer dissociation, and electron-transfer and higher-energy collision dissociation MS/MS spectra of peptides with >0.9 median Pearson correlation coefficients. Further, we showed that intermediate layer of the neural network could reveal physicochemical properties of amino acids, for example the similarities of fragmentation behaviors between amino acids. We also showed the potential of pDeep to distinguish extremely similar peptides (peptides that contain isobaric amino acids, for example, GG = N, AG = Q, or even I = L), which were very difficult to distinguish using traditional search engines.

  2. Some practical applications of an ICP-MS instrument

    International Nuclear Information System (INIS)

    Meddings, B.; Ng, R.

    1987-01-01

    An early model commercial ICP-MS instrument (PlasmaQuad from VG Isotopes Limited) was acquired more than two years ago. As a typical analytical laboratory in the metallurgical field, the application of the ICP-MS technique to real sample analysis is the authors prime concern. The process of introducing this state-of-the-art instrument into routine analysis will be described. The modifications and limitations necessary to achieve acceptable precision under normal working conditions will be outlined. In most cases, practical problems can be circumvented with some sacrifice in analytical performance in the area of detection limits and dynamic range. In this presentation, specific applications of the ICP-MS technique in the authors laboratory will be discussed. These include trace analysis on high purity metals such as copper, aluminum, cobalt, nickel etc., on refinery feed samples such as nickel sulfate, mixed cobalt and nickel sulfide, cobalt cathode, samarium oxide etc., on alloys such as cobalt-samarium magnetic materials, nickel or cobalt based alloys used in turbine blades etc. Other applications such as the determination of uranium in phosphate rock, trace analysis on fertilizers, water samples and high purity acids will also be mentioned. The solutions to the practical problems encountered in these applications will be discussed. The analytical power of the ICP-MS technique for real sample analysis will be assessed

  3. Ambient measurements of aromatic and oxidized VOCs by PTR-MS and GC-MS: intercomparison between four instruments in a boreal forest in Finland

    Science.gov (United States)

    Kajos, M. K.; Rantala, P.; Hill, M.; Hellén, H.; Aalto, J.; Patokoski, J.; Taipale, R.; Hoerger, C. C.; Reimann, S.; Ruuskanen, T. M.; Rinne, J.; Petäjä, T.

    2015-10-01

    Proton transfer reaction mass spectrometry (PTR-MS) and gas chromatography mass spectrometry GC-MS) are commonly used methods for automated in situ measurements of various volatile organic compounds (VOCs) in the atmosphere. In order to investigate the reliability of such measurements, we operated four automated analyzers using their normal field measurement protocol side by side at a boreal forest site. We measured methanol, acetaldehyde, acetone, benzene and toluene by two PTR-MS and two GC-MS instruments. The measurements were conducted in southern Finland between 13 April and 14 May 2012. This paper presents correlations and biases between the concentrations measured using the four instruments. A very good correlation was found for benzene and acetone measurements between all instruments (the mean R value was 0.88 for both compounds), while for acetaldehyde and toluene the correlation was weaker (with a mean R value of 0.50 and 0.62, respectively). For some compounds, notably for methanol, there were considerable systematic differences in the mixing ratios measured by the different instruments, despite the very good correlation between the instruments (mean R = 0.90). The systematic difference manifests as a difference in the linear regression slope between measurements conducted between instruments, rather than as an offset. This mismatch indicates that the systematic uncertainty in the sensitivity of a given instrument can lead to an uncertainty of 50-100 % in the methanol emissions measured by commonly used methods.

  4. Developments in FT-ICR MS instrumentation, ionization techniques, and data interpretation methods for petroleomics.

    Science.gov (United States)

    Cho, Yunju; Ahmed, Arif; Islam, Annana; Kim, Sunghwan

    2015-01-01

    Because of the increasing importance of heavy and unconventional crude oil as an energy source, there is a growing need for petroleomics: the pursuit of more complete and detailed knowledge of the chemical compositions of crude oil. Crude oil has an extremely complex nature; hence, techniques with ultra-high resolving capabilities, such as Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), are necessary. FT-ICR MS has been successfully applied to the study of heavy and unconventional crude oils such as bitumen and shale oil. However, the analysis of crude oil with FT-ICR MS is not trivial, and it has pushed analysis to the limits of instrumental and methodological capabilities. For example, high-resolution mass spectra of crude oils may contain over 100,000 peaks that require interpretation. To visualize large data sets more effectively, data processing methods such as Kendrick mass defect analysis and statistical analyses have been developed. The successful application of FT-ICR MS to the study of crude oil has been critically dependent on key developments in FT-ICR MS instrumentation and data processing methods. This review offers an introduction to the basic principles, FT-ICR MS instrumentation development, ionization techniques, and data interpretation methods for petroleomics and is intended for readers having no prior experience in this field of study. © 2014 Wiley Periodicals, Inc.

  5. Instrument uncertainty predictions

    International Nuclear Information System (INIS)

    Coutts, D.A.

    1991-07-01

    The accuracy of measurements and correlations should normally be provided for most experimental activities. The uncertainty is a measure of the accuracy of a stated value or equation. The uncertainty term reflects a combination of instrument errors, modeling limitations, and phenomena understanding deficiencies. This report provides several methodologies to estimate an instrument's uncertainty when used in experimental work. Methods are shown to predict both the pretest and post-test uncertainty

  6. Structure Elucidation of Unknown Metabolites in Metabolomics by Combined NMR and MS/MS Prediction.

    Science.gov (United States)

    Boiteau, Rene M; Hoyt, David W; Nicora, Carrie D; Kinmonth-Schultz, Hannah A; Ward, Joy K; Bingol, Kerem

    2018-01-17

    We introduce a cheminformatics approach that combines highly selective and orthogonal structure elucidation parameters; accurate mass, MS/MS (MS²), and NMR into a single analysis platform to accurately identify unknown metabolites in untargeted studies. The approach starts with an unknown LC-MS feature, and then combines the experimental MS/MS and NMR information of the unknown to effectively filter out the false positive candidate structures based on their predicted MS/MS and NMR spectra. We demonstrate the approach on a model mixture, and then we identify an uncatalogued secondary metabolite in Arabidopsis thaliana . The NMR/MS² approach is well suited to the discovery of new metabolites in plant extracts, microbes, soils, dissolved organic matter, food extracts, biofuels, and biomedical samples, facilitating the identification of metabolites that are not present in experimental NMR and MS metabolomics databases.

  7. Impact of and correction for instrument sensitivity drift on nanoparticle size measurements by single-particle ICP-MS

    Science.gov (United States)

    El Hadri, Hind; Petersen, Elijah J.; Winchester, Michael R.

    2016-01-01

    The effect of ICP-MS instrument sensitivity drift on the accuracy of NP size measurements using single particle (sp)ICP-MS is investigated. Theoretical modeling and experimental measurements of the impact of instrument sensitivity drift are in agreement and indicate that drift can impact the measured size of spherical NPs by up to 25 %. Given this substantial bias in the measured size, a method was developed using an internal standard to correct for the impact of drift and was shown to accurately correct for a decrease in instrument sensitivity of up to 50 % for 30 nm and 60 nm gold nanoparticles. PMID:26894759

  8. Predicting child maltreatment: A meta-analysis of the predictive validity of risk assessment instruments.

    Science.gov (United States)

    van der Put, Claudia E; Assink, Mark; Boekhout van Solinge, Noëlle F

    2017-11-01

    Risk assessment is crucial in preventing child maltreatment since it can identify high-risk cases in need of child protection intervention. Despite widespread use of risk assessment instruments in child welfare, it is unknown how well these instruments predict maltreatment and what instrument characteristics are associated with higher levels of predictive validity. Therefore, a multilevel meta-analysis was conducted to examine the predictive accuracy of (characteristics of) risk assessment instruments. A literature search yielded 30 independent studies (N=87,329) examining the predictive validity of 27 different risk assessment instruments. From these studies, 67 effect sizes could be extracted. Overall, a medium significant effect was found (AUC=0.681), indicating a moderate predictive accuracy. Moderator analyses revealed that onset of maltreatment can be better predicted than recurrence of maltreatment, which is a promising finding for early detection and prevention of child maltreatment. In addition, actuarial instruments were found to outperform clinical instruments. To bring risk and needs assessment in child welfare to a higher level, actuarial instruments should be further developed and strengthened by distinguishing risk assessment from needs assessment and by integrating risk assessment with case management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. The CAREQOL-MS was a useful instrument to measure caregiver quality of life in multiple sclerosis.

    Science.gov (United States)

    Benito-León, Julián; Rivera-Navarro, Jesús; Guerrero, Angel Luis; de Las Heras, Virginia; Balseiro, José; Rodríguez, Elena; Belló, Mireia; Martínez-Martín, Pablo

    2011-06-01

    To develop and test the first specific instrument for assessing caregiver health-related quality of life (HRQOL) in multiple sclerosis (MS) (CAREQOL-MS). Questionnaire items were derived from a literature review and the views of patients, caregivers, and experts. Instrument was reduced after the analyses of caregivers' interviews and experts' opinions. CAREQOL-MS psychometric properties were assessed in 276 MS caregivers. The final version consisted of 24 items (five subscales) and was free of floor or ceiling effects. For subscales, the Cronbach's alpha coefficient ranged from 0.75 to 0.90. The item-total correlation was 0.62-0.74 for subscale I (physical burden/global health); 0.56-0.74 for subscale II (social impact); 0.52-0.62 for subscale III (emotional impact), and 0.58-0.65 for subscale IV (need of help); subscale V (emotional reactions) had only two items. The intraclass correlation coefficient (0.96 for the total score; 0.75-0.95 for subscales) suggested satisfactory reproducibility. Association was close between CAREQOL-MS subscales and the Zarit burden interview and moderate with short form 36 mental/physical components. CAREQOL-MS subscales scores significantly increased (worse HRQOL) with increasing caregivers' age and Expanded Disability Status Scale. The standard error of the measurement ranged from 0.91 to 2.43 for subscales. Our results provided initial evidence of the usefulness and satisfactory psychometric properties of the CAREQOL-MS. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Educational Program Improvement in Chemistry Through the Acquisition of GC/MS And FT-NMR Instruments

    National Research Council Canada - National Science Library

    Anderson, Gloria

    1997-01-01

    ...), Department of Defense. The purpose of this grant was to enable the department to acquire instrumentation necessary for incorporating the theory and practice of Gas Chromatography/Mass Spectrometry (GC/MS...

  11. [Clinical Application of Analytical and Medical Instruments Mainly Using MS Techniques].

    Science.gov (United States)

    Tanaka, Koichi

    2016-02-01

    Analytical instruments for clinical use are commonly required to confirm the compounds and forms related to diseases with the highest possible sensitivity, quantitative performance, and specificity and minimal invasiveness within a short time, easily, and at a low cost. Advancements of technical innovation for Mass Spectrometer (MS) have led to techniques that meet such requirements. Besides confirming known substances, other purposes and advantages of MS that are not fully known to the public are using MS as a tool to discover unknown phenomena and compounds. An example is clarifying the mechanisms of human diseases. The human body has approximately 100 thousand types of protein, and there may be more than several million types of protein and their metabolites. Most of them have yet to be discovered, and their discovery may give birth to new academic fields and lead to the clarification of diseases, development of new medicines, etc. For example, using the MS system developed under "Contribution to drug discovery and diagnosis by next generation of advanced mass spectrometry system," one of the 30 projects of the "Funding Program for World-Leading Innovative R&D on Science and Technology" (FIRST program), and other individual basic technologies, we succeeded in discovering new disease biomarker candidates for Alzheimer's disease, cancer, etc. Further contribution of MS to clinical medicine can be expected through the development and improvement of new techniques, efforts to verify discoveries, and communications with the medical front.

  12. A Computational Framework for Proteome-Wide Pursuit and Prediction of Metalloproteins using ICP-MS and MS/MS Data

    Directory of Open Access Journals (Sweden)

    Trauger Sunia A

    2011-02-01

    Full Text Available Abstract Background Metal-containing proteins comprise a diverse and sizable category within the proteomes of organisms, ranging from proteins that use metals to catalyze reactions to proteins in which metals play key structural roles. Unfortunately, reliably predicting that a protein will contain a specific metal from its amino acid sequence is not currently possible. We recently developed a generally-applicable experimental technique for finding metalloproteins on a genome-wide scale. Applying this metal-directed protein purification approach (ICP-MS and MS/MS based to the prototypical microbe Pyrococcus furiosus conclusively demonstrated the extent and diversity of the uncharacterized portion of microbial metalloproteomes since a majority of the observed metal peaks could not be assigned to known or predicted metalloproteins. However, even using this technique, it is not technically feasible to purify to homogeneity all metalloproteins in an organism. In order to address these limitations and complement the metal-directed protein purification, we developed a computational infrastructure and statistical methodology to aid in the pursuit and identification of novel metalloproteins. Results We demonstrate that our methodology enables predictions of metal-protein interactions using an experimental data set derived from a chromatography fractionation experiment in which 870 proteins and 10 metals were measured over 2,589 fractions. For each of the 10 metals, cobalt, iron, manganese, molybdenum, nickel, lead, tungsten, uranium, vanadium, and zinc, clusters of proteins frequently occurring in metal peaks (of a specific metal within the fractionation space were defined. This resulted in predictions that there are from 5 undiscovered vanadium- to 13 undiscovered cobalt-containing proteins in Pyrococcus furiosus. Molybdenum and nickel were chosen for additional assessment producing lists of genes predicted to encode metalloproteins or metalloprotein

  13. The role of domain analysis in prediction instrument development

    NARCIS (Netherlands)

    van der Spoel, Sjoerd; Amrit, Chintan Amrit; van Hillegersberg, Jos

    2016-01-01

    In order to develop prediction instruments that have sufficient predictive power, it is essential to understand the specific domain the prediction instrument is developed for. This domain analysis is especially important for domains where human behavior, politics, or other soft factors play a role.

  14. A compact PTR-ToF-MS instrument for airborne measurements of volatile organic compounds at high spatiotemporal resolution

    Directory of Open Access Journals (Sweden)

    M. Müller

    2014-11-01

    Full Text Available Herein, we report on the development of a compact proton-transfer-reaction time-of-flight mass spectrometer (PTR-ToF-MS for airborne measurements of volatile organic compounds (VOCs. The new instrument resolves isobaric ions with a mass resolving power (m/Δm of ~1000, provides accurate m/z measurements (Δm < 3 mDa, records full mass spectra at 1 Hz and thus overcomes some of the major analytical deficiencies of quadrupole-MS-based airborne instruments. 1 Hz detection limits for biogenic VOCs (isoprene, α total monoterpenes, aromatic VOCs (benzene, toluene, xylenes and ketones (acetone, methyl ethyl ketone range from 0.05 to 0.12 ppbV, making the instrument well-suited for fast measurements of abundant VOCs in the continental boundary layer. The instrument detects and quantifies VOCs in locally confined plumes (< 1 km, which improves our capability of characterizing emission sources and atmospheric processing within plumes. A deployment during the NASA 2013 DISCOVER-AQ mission generated high vertical- and horizontal-resolution in situ data of VOCs and ammonia for the validation of satellite retrievals and chemistry transport models.

  15. Automated protein identification by the combination of MALDI MS and MS/MS spectra from different instruments.

    Science.gov (United States)

    Levander, Fredrik; James, Peter

    2005-01-01

    The identification of proteins separated on two-dimensional gels is most commonly performed by trypsin digestion and subsequent matrix-assisted laser desorption ionization (MALDI) with time-of-flight (TOF). Recently, atmospheric pressure (AP) MALDI coupled to an ion trap (IT) has emerged as a convenient method to obtain tandem mass spectra (MS/MS) from samples on MALDI target plates. In the present work, we investigated the feasibility of using the two methodologies in line as a standard method for protein identification. In this setup, the high mass accuracy MALDI-TOF spectra are used to calibrate the peptide precursor masses in the lower mass accuracy AP-MALDI-IT MS/MS spectra. Several software tools were developed to automate the analysis process. Two sets of MALDI samples, consisting of 142 and 421 gel spots, respectively, were analyzed in a highly automated manner. In the first set, the protein identification rate increased from 61% for MALDI-TOF only to 85% for MALDI-TOF combined with AP-MALDI-IT. In the second data set the increase in protein identification rate was from 44% to 58%. AP-MALDI-IT MS/MS spectra were in general less effective than the MALDI-TOF spectra for protein identification, but the combination of the two methods clearly enhanced the confidence in protein identification.

  16. Validation predictions of a 13 m/s cross-wind fire for Fuego and the University of Waterloo dataset.

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Alexander L.; Evans, Gregory Herbert (Sandia National Laboratories, Livermore, CA); Gill, Walter; Jarboe, Daniel T. (Sandia National Laboratories, Livermore, CA)

    2008-03-01

    Detailed herein are the results of a validation comparison. The experiment involved a 2 meter diameter liquid pool of Jet-A fuel in a 13 m/s crosswind. The scenario included a large cylindrical blocking object just down-stream of the fire. It also included seven smaller calorimeters and extensive instrumentation. The experiments were simulated with Fuego. The model included several conduction regions to model the response of the calorimeters, the floor, and the large cylindrical blocking object. A blind comparison was used to compare the simulation predictions with the experimental data. The more upstream data compared very well with the simulation predictions. The more downstream data did not compare very well with the simulation predictions. Further investigation suggests that features omitted from the original model contributed to the discrepancies. Observations are made with respect to the scenario that are aimed at helping an analyst approach a comparable problem in a way that may help improve the potential for quantitative accuracy.

  17. Low predictability of anthropometric indicators of obesity in metabolic syndrome (MS) risks among elderly women.

    Science.gov (United States)

    Chu, Fu-Ling; Hsu, Chung-Huei; Jeng, Chii

    2012-01-01

    While diagnostic criteria for MS may vary depending on ethnicity, obesity remains a key risk factor in its development. In Taiwan, the incidence of obesity and MS among women has been increasing; however cut-off values for defining obesity for the diagnosis of MS among different groups of women have not been clearly established. The goal of this research was to examine the suitability of various anthropometric indicators of obesity in predicting the presence of MS criteria and to determine appropriate cut-off values of these indicators for women of different age and menstrual status. The sample was derived from the 2002 "Taiwan Three High Prevalence Survey" database. Women were divided into three groups based on age and menstrual status. Receiver-operating characteristic (ROC) curves was applied to the anthropometric indicators of obesity including, body mass index (BMI), waist circumference (WC), waist-to-hip ratio (WHR), waist-to-height ratio (WHtR), to ascertain its value in predicting MS. 2848 cases were included. It was found that most MS component values were worse with age and following menopause. Obesity indicators showed poor predictability for MS risks in post-menopausal women over 65 years, but good predictability in women under 65 years; our study revealed the following as ideal cut-off values for non-menopausal female: WHtRrisks in women over the age of 65, and cut-off values for obesity indicators need to be further reduced in non-menopausal women. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. DI/LC-MS/MS-Based Metabolic Profiling for Identification of Early Predictive Serum Biomarkers of Metritis in Transition Dairy Cows.

    Science.gov (United States)

    Zhang, Guanshi; Deng, Qilan; Mandal, Rupasri; Wishart, David S; Ametaj, Burim N

    2017-09-27

    The objectives of this study were to evaluate alterations of metabolites in the blood of dairy cows before, during, and after diagnosis of metritis and identify predictive serum metabolite biomarkers for metritis. DI/LC-MS/MS was used to analyze serum samples collected from both healthy and metritic cows during -8, -4, disease diagnosis, +4, and +8 wks relative to parturition. Results indicated that cows with metritis experienced altered concentrations of serum amino acids, glycerophospholipids, sphingolipids, acylcarnitines, and biogenic amines during the entire experimental period. Moreover, two sets of predictive biomarker models and one set of diagnostic biomarker models for metritis were developed, and all of them showed high sensitivity and specificity (e.g., high AUC values by the ROC curve evaluation), which indicate that serum metabolites identified have pretty accurate predictive, diagnostic, and prognostic abilities for metritis in transition dairy cows.

  19. Predicting College Women's Career Plans: Instrumentality, Work, and Family

    Science.gov (United States)

    Savela, Alexandra E.; O'Brien, Karen M.

    2016-01-01

    This study examined how college women's instrumentality and expectations about combining work and family predicted early career development variables. Specifically, 177 undergraduate women completed measures of instrumentality (i.e., traits such as ambition, assertiveness, and risk taking), willingness to compromise career for family, anticipated…

  20. Developing the Cleanliness Requirements for an Organic-detection Instrument MOMA-MS

    Science.gov (United States)

    Perry, Radford; Canham, John; Lalime, Erin

    2015-01-01

    The cleanliness requirements for an organic-detection instrument, like the Mars Organic Molecule Analyzer Mass Spectrometer (MOMA-MS), on a Planetary Protection Class IVb mission can be extremely stringent. These include surface molecular and particulate, outgassing, and bioburden. The prime contractor for the European Space Agencys ExoMars 2018 project, Thales Alenia Space Italy, provided requirements based on a standard, conservative approach of defining limits which yielded levels that are unverifiable by standard cleanliness verification methods. Additionally, the conservative method for determining contamination surface area uses underestimation while conservative bioburden surface area relies on overestimation, which results in inconsistencies for the normalized reporting. This presentation will provide a survey of the challenge to define requirements that can be reasonably verified and still remain appropriate to the core science of the ExoMars mission.

  1. The APEX Quantitative Proteomics Tool: Generating protein quantitation estimates from LC-MS/MS proteomics results

    Directory of Open Access Journals (Sweden)

    Saeed Alexander I

    2008-12-01

    Full Text Available Abstract Background Mass spectrometry (MS based label-free protein quantitation has mainly focused on analysis of ion peak heights and peptide spectral counts. Most analyses of tandem mass spectrometry (MS/MS data begin with an enzymatic digestion of a complex protein mixture to generate smaller peptides that can be separated and identified by an MS/MS instrument. Peptide spectral counting techniques attempt to quantify protein abundance by counting the number of detected tryptic peptides and their corresponding MS spectra. However, spectral counting is confounded by the fact that peptide physicochemical properties severely affect MS detection resulting in each peptide having a different detection probability. Lu et al. (2007 described a modified spectral counting technique, Absolute Protein Expression (APEX, which improves on basic spectral counting methods by including a correction factor for each protein (called Oi value that accounts for variable peptide detection by MS techniques. The technique uses machine learning classification to derive peptide detection probabilities that are used to predict the number of tryptic peptides expected to be detected for one molecule of a particular protein (Oi. This predicted spectral count is compared to the protein's observed MS total spectral count during APEX computation of protein abundances. Results The APEX Quantitative Proteomics Tool, introduced here, is a free open source Java application that supports the APEX protein quantitation technique. The APEX tool uses data from standard tandem mass spectrometry proteomics experiments and provides computational support for APEX protein abundance quantitation through a set of graphical user interfaces that partition thparameter controls for the various processing tasks. The tool also provides a Z-score analysis for identification of significant differential protein expression, a utility to assess APEX classifier performance via cross validation, and a

  2. Warped Linear Prediction of Physical Model Excitations with Applications in Audio Compression and Instrument Synthesis

    Science.gov (United States)

    Glass, Alexis; Fukudome, Kimitoshi

    2004-12-01

    A sound recording of a plucked string instrument is encoded and resynthesized using two stages of prediction. In the first stage of prediction, a simple physical model of a plucked string is estimated and the instrument excitation is obtained. The second stage of prediction compensates for the simplicity of the model in the first stage by encoding either the instrument excitation or the model error using warped linear prediction. These two methods of compensation are compared with each other, and to the case of single-stage warped linear prediction, adjustments are introduced, and their applications to instrument synthesis and MPEG4's audio compression within the structured audio format are discussed.

  3. SIMPATIQCO: a server-based software suite which facilitates monitoring the time course of LC-MS performance metrics on Orbitrap instruments.

    Science.gov (United States)

    Pichler, Peter; Mazanek, Michael; Dusberger, Frederico; Weilnböck, Lisa; Huber, Christian G; Stingl, Christoph; Luider, Theo M; Straube, Werner L; Köcher, Thomas; Mechtler, Karl

    2012-11-02

    While the performance of liquid chromatography (LC) and mass spectrometry (MS) instrumentation continues to increase, applications such as analyses of complete or near-complete proteomes and quantitative studies require constant and optimal system performance. For this reason, research laboratories and core facilities alike are recommended to implement quality control (QC) measures as part of their routine workflows. Many laboratories perform sporadic quality control checks. However, successive and systematic longitudinal monitoring of system performance would be facilitated by dedicated automatic or semiautomatic software solutions that aid an effortless analysis and display of QC metrics over time. We present the software package SIMPATIQCO (SIMPle AuTomatIc Quality COntrol) designed for evaluation of data from LTQ Orbitrap, Q-Exactive, LTQ FT, and LTQ instruments. A centralized SIMPATIQCO server can process QC data from multiple instruments. The software calculates QC metrics supervising every step of data acquisition from LC and electrospray to MS. For each QC metric the software learns the range indicating adequate system performance from the uploaded data using robust statistics. Results are stored in a database and can be displayed in a comfortable manner from any computer in the laboratory via a web browser. QC data can be monitored for individual LC runs as well as plotted over time. SIMPATIQCO thus assists the longitudinal monitoring of important QC metrics such as peptide elution times, peak widths, intensities, total ion current (TIC) as well as sensitivity, and overall LC-MS system performance; in this way the software also helps identify potential problems. The SIMPATIQCO software package is available free of charge.

  4. An Automated Sample Preparation Instrument to Accelerate Positive Blood Cultures Microbial Identification by MALDI-TOF Mass Spectrometry (Vitek®MS

    Directory of Open Access Journals (Sweden)

    Patrick Broyer

    2018-05-01

    Full Text Available Sepsis is the leading cause of death among patients in intensive care units (ICUs requiring an early diagnosis to introduce efficient therapeutic intervention. Rapid identification (ID of a causative pathogen is key to guide directed antimicrobial selection and was recently shown to reduce hospitalization length in ICUs. Direct processing of positive blood cultures by MALDI-TOF MS technology is one of the several currently available tools used to generate rapid microbial ID. However, all recently published protocols are still manual and time consuming, requiring dedicated technician availability and specific strategies for batch processing. We present here a new prototype instrument for automated preparation of Vitek®MS slides directly from positive blood culture broth based on an “all-in-one” extraction strip. This bench top instrument was evaluated on 111 and 22 organisms processed using artificially inoculated blood culture bottles in the BacT/ALERT® 3D (SA/SN blood culture bottles or the BacT/ALERT VirtuoTM system (FA/FN Plus bottles, respectively. Overall, this new preparation station provided reliable and accurate Vitek MS species-level identification of 87% (Gram-negative bacteria = 85%, Gram-positive bacteria = 88%, and yeast = 100% when used with BacT/ALERT® 3D and of 84% (Gram-negative bacteria = 86%, Gram-positive bacteria = 86%, and yeast = 75% with Virtuo® instruments, respectively. The prototype was then evaluated in a clinical microbiology laboratory on 102 clinical blood culture bottles and compared to routine laboratory ID procedures. Overall, the correlation of ID on monomicrobial bottles was 83% (Gram-negative bacteria = 89%, Gram-positive bacteria = 79%, and yeast = 78%, demonstrating roughly equivalent performance between manual and automatized extraction methods. This prototype instrument exhibited a high level of performance regardless of bottle type or BacT/ALERT system. Furthermore, blood culture workflow could

  5. Diet-induced perturbation of the rat liver mitochondrial acetylome studied by quantitative (iTRAQ) LC-MS/MS

    DEFF Research Database (Denmark)

    León, Ileana R.; Schwämmle, Veit; Williamson, James

    described3. Quantitation by MS/MS was achieved by using iTRAQ 8-Plex reagents (Life Technologies). LC-MS/MS analyses were performed using an Easy-nLC (Proxeon/ThermoFisher) fitted with an in-house made 17 cm C18 column that was interfaced to an LTQ-OrbiTrap XL instrument (ThermoFisher). Data analysis...

  6. VOC identification and inter-comparison from laboratory biomass burning using PTR-MS and PIT-MS

    Science.gov (United States)

    C. Warneke; J. M. Roberts; P. Veres; J. Gilman; W. C. Kuster; I. Burling; R. Yokelson; J. A. de Gouw

    2011-01-01

    Volatile organic compounds (VOCs) emitted from fires of biomass commonly found in the southeast and southwest U.S. were investigated with PTR-MS and PIT-MS, which are capable of fast measurements of a large number of VOCs. Both instruments were calibrated with gas standards and mass dependent calibration curves are determined. The sensitivity of the PIT-MS linearly...

  7. An in silico MS/MS library for automatic annotation of novel FAHFA lipids.

    Science.gov (United States)

    Ma, Yan; Kind, Tobias; Vaniya, Arpana; Gennity, Ingrid; Fahrmann, Johannes F; Fiehn, Oliver

    2015-01-01

    A new lipid class named 'fatty acid esters of hydroxyl fatty acids' (FAHFA) was recently discovered in mammalian adipose tissue and in blood plasma and some FAHFAs were found to be associated with type 2 diabetes. To facilitate the automatic annotation of FAHFAs in biological specimens, a tandem mass spectra (MS/MS) library is needed. Due to the limitation of the commercial available standard compounds, we proposed building an in silico MS/MS library to extend the coverage of molecules. We developed a computer-generated library with 3267 tandem mass spectra (MS/MS) for 1089 FAHFA species. FAHFA spectra were generated based on authentic standards with negative mode electrospray ionization and 10, 20, and 40 V collision induced dissociation at 4 spectra/s as used in in ultra-high performance liquid chromatography-QTOF mass spectrometry studies. However, positional information of the hydroxyl group is only obtained either at lower QTOF spectra acquisition rates of 1 spectrum/s or at the MS(3) level in ion trap instruments. Therefore, an additional set of 4290 fragment-rich MS/MS spectra was created to enable distinguishing positional FAHFA isomers. The library was generated based on ion fragmentations and ion intensities of FAHFA external reference standards, developing a heuristic model for fragmentation rules and extending these rules to large swaths of computer-generated structures of FAHFAs with varying chain lengths, degrees of unsaturation and hydroxyl group positions. Subsequently, we validated the new in silico library by discovering several new FAHFA species in egg yolk, showing that this library enables high-throughput screening of FAHFA lipids in various biological matrices. The developed library and templates are freely available for commercial or noncommercial use at http://fiehnlab.ucdavis.edu/staff/yanma/fahfa-lipid-library. This in silico MS/MS library allows users to annotate FAHFAs from accurate mass tandem mass spectra in an easy and fast manner

  8. Measurement techniques and instruments suitable for life-prediction testing of photovoltaic arrays. Interim report

    Energy Technology Data Exchange (ETDEWEB)

    Noel, G.T.; Sliemers, F.A.; Deringer, G.C.; Wood, V.E.; Wilkes, K.E.; Gaines, G.B.; Carmichael, D.C.

    1978-01-15

    The validation of a service life of 20 years for low-cost photovoltaic arrays must be accomplished through accelerated life-prediction tests. A methodology for such tests has been developed in a preceding study. The results discussed consist of the initial identification and assessment of all known measurement techniques and instruments that might be used in these life-prediction tests. Array failure modes, relevant materials property changes, and primary degradation mechanisms are discussed as a prerequisite to identifying suitable measurement techniques and instruments. Candidate techniques and instruments are identified on the basis of extensive reviews of published and unpublished information. These methods are organized in six measurement categories--chemical, electrical, optical, thermal, mechanical, and ''other physicals''. Using specified evaluation criteria, the most promising techniques and instruments for use in life-prediction tests of arrays are then selected. These recommended techniques and their characteristics are described. Recommendations are made regarding establishment of the adequacy, particularly with respect to precision, of the more fully developed techniques for this application, and regarding the experimental evaluation of promising developmental techniques. Measurement needs not satisfied by presently available techniques/instruments are also identified.

  9. Analytical improvements of hybrid LC-MS/MS techniques for the efficient evaluation of emerging contaminants in river waters: a case study of the Henares River (Madrid, Spain).

    Science.gov (United States)

    Pérez-Parada, Andrés; Gómez-Ramos, María del Mar; Martínez Bueno, María Jesús; Uclés, Samanta; Uclés, Ana; Fernández-Alba, Amadeo R

    2012-02-01

    Instrumental capabilities and software tools of modern hybrid mass spectrometry (MS) instruments such as high-resolution mass spectrometry (HRMS), quadrupole time-of-flight (QTOF), and quadrupole linear ion trap (QLIT) were experimentally investigated for the study of emerging contaminants in Henares River water samples. Automated screening and confirmatory capabilities of QTOF working in full-scan MS and tandem MS (MS/MS) were explored when dealing with real samples. Investigations on the effect of sensitivity and resolution power influence on mass accuracy were studied for the correct assignment of the amoxicillin transformation product 5(R) amoxicillin-diketopiperazine-2',5' as an example of a nontarget compound. On the other hand, a comparison of quantitative and qualitative strategies based on direct injection analysis and off-line solid-phase extraction sample treatment were assayed using two different QLIT instruments for a selected group of emerging contaminants when operating in selected reaction monitoring (SRM) and information-dependent acquisition (IDA) modes. Software-aided screening usually needs a further confirmatory step. Resolving power and MS/MS feature of QTOF showed to confirm/reject most findings in river water, although sensitivity-related limitations are usually found. Superior sensitivity of modern QLIT-MS/MS offered the possibility of direct injection analysis for proper quantitative study of a variety of contaminants, while it simultaneously reduced the matrix effect and increased the reliability of the results. Confirmation of ethylamphetamine, which lacks on a second SRM transition, was accomplished by using the IDA feature. Hybrid MS instruments equipped with high resolution and high sensitivity contributes to enlarge the scope of targeted analytes in river waters. However, in the tested instruments, there is a margin of improvement principally in required sensitivity and data treatment software tools devoted to reliable confirmation

  10. 99Tc atom counting by quadrupole ICP-MS. Optimisation of the instrumental response

    International Nuclear Information System (INIS)

    Mas, Jose L.; Garcia-Leon, Manuel; Bolivar, Juan P.

    2002-01-01

    In this paper, an extensive work is done on the specific tune of a conventional ICP-MS for 99 Tc atom counting. For this, two methods have been used and compared: the partial variable control method and the 5D Simplex method. Instrumental limits of detection of 0.2 and 0.8 ppt, respectively, were obtained. They are noticeably lower than that found with the automatic tune method of the spectrometer, 47 ppt, which shows the need of a specific tune when very low levels of 99 Tc have to be determined. A study is presented on the mass interferences for 99 Tc. Our experiments show that the formation of polyatomic atoms or refractory oxides as well as 98 Mo hydrides seem to be irrelevant for 99 Tc atom counting. The opposite occurs with the presence of isobaric interferences, i.e. 99 Ru, and the effect of abundance sensitivity, or low-mass resolution, which can modify the response at m/z=99 to a non-negligible extent

  11. Human dorsal striatum encodes prediction errors during observational learning of instrumental actions.

    Science.gov (United States)

    Cooper, Jeffrey C; Dunne, Simon; Furey, Teresa; O'Doherty, John P

    2012-01-01

    The dorsal striatum plays a key role in the learning and expression of instrumental reward associations that are acquired through direct experience. However, not all learning about instrumental actions require direct experience. Instead, humans and other animals are also capable of acquiring instrumental actions by observing the experiences of others. In this study, we investigated the extent to which human dorsal striatum is involved in observational as well as experiential instrumental reward learning. Human participants were scanned with fMRI while they observed a confederate over a live video performing an instrumental conditioning task to obtain liquid juice rewards. Participants also performed a similar instrumental task for their own rewards. Using a computational model-based analysis, we found reward prediction errors in the dorsal striatum not only during the experiential learning condition but also during observational learning. These results suggest a key role for the dorsal striatum in learning instrumental associations, even when those associations are acquired purely by observing others.

  12. microMS: A Python Platform for Image-Guided Mass Spectrometry Profiling

    Science.gov (United States)

    Comi, Troy J.; Neumann, Elizabeth K.; Do, Thanh D.; Sweedler, Jonathan V.

    2017-09-01

    Image-guided mass spectrometry (MS) profiling provides a facile framework for analyzing samples ranging from single cells to tissue sections. The fundamental workflow utilizes a whole-slide microscopy image to select targets of interest, determine their spatial locations, and subsequently perform MS analysis at those locations. Improving upon prior reported methodology, a software package was developed for working with microscopy images. microMS, for microscopy-guided mass spectrometry, allows the user to select and profile diverse samples using a variety of target patterns and mass analyzers. Written in Python, the program provides an intuitive graphical user interface to simplify image-guided MS for novice users. The class hierarchy of instrument interactions permits integration of new MS systems while retaining the feature-rich image analysis framework. microMS is a versatile platform for performing targeted profiling experiments using a series of mass spectrometers. The flexibility in mass analyzers greatly simplifies serial analyses of the same targets by different instruments. The current capabilities of microMS are presented, and its application for off-line analysis of single cells on three distinct instruments is demonstrated. The software has been made freely available for research purposes. [Figure not available: see fulltext.

  13. The predictive power of SIMION/SDS simulation software for modeling ion mobility spectrometry instruments

    Science.gov (United States)

    Lai, Hanh; McJunkin, Timothy R.; Miller, Carla J.; Scott, Jill R.; Almirall, José R.

    2008-09-01

    The combined use of SIMION 7.0 and the statistical diffusion simulation (SDS) user program in conjunction with SolidWorks® with COSMSOSFloWorks® fluid dynamics software to model a complete, commercial ion mobility spectrometer (IMS) was demonstrated for the first time and compared to experimental results for tests using compounds of immediate interest in the security industry (e.g., 2,4,6-trinitrotoluene, 2,7-dinitrofluorene, and cocaine). The effort of this research was to evaluate the predictive power of SIMION/SDS for application to IMS instruments. The simulation was evaluated against experimental results in three studies: (1) a drift:carrier gas flow rates study assesses the ability of SIMION/SDS to correctly predict the ion drift times; (2) a drift gas composition study evaluates the accuracy in predicting the resolution; (3) a gate width study compares the simulated peak shape and peak intensity with the experimental values. SIMION/SDS successfully predicted the correct drift time, intensity, and resolution trends for the operating parameters studied. Despite the need for estimations and assumptions in the construction of the simulated instrument, SIMION/SDS was able to predict the resolution between two ion species in air within 3% accuracy. The preliminary success of IMS simulations using SIMION/SDS software holds great promise for the design of future instruments with enhanced performance.

  14. The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements†

    Science.gov (United States)

    Pröfrock, Daniel; Irrgeher, Johanna; Prohaska, Thomas

    2016-01-01

    The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC, measurement repeatability, within-lab reproducibility and deviation from certified values as well as a study on instrumental isotopic fractionation (IIF) and the calculation of the combined standard measurement uncertainty. Different approaches of correction for IIF applying external intra-elemental IIF correction (aka standard-sample bracketing) using certified S reference materials and internal inter-elemental IIF (aka internal standardization) correction using Si isotope ratios in MC ICP-MS are explained and compared. The resulting combined standard uncertainties of examined ICP-QMS systems were not better than 0.3–0.5% (uc,rel), which is in general insufficient to differentiate natural S isotope variations. Although the performance of the single collector ICP-SFMS is better (single measurement uc,rel = 0.08%), the measurement reproducibility (>0.2%) is the major limit of this system and leaves room for improvement. MC ICP-MS operated in the edge mass resolution mode, applying bracketing for correction of IIF, provided isotope ratio values with the highest quality (relative combined measurement uncertainty: 0.02%; deviation from the certified value: <0.002%). PMID:27812369

  15. Software ion scan functions in analysis of glycomic and lipidomic MS/MS datasets.

    Science.gov (United States)

    Haramija, Marko

    2018-03-01

    Hardware ion scan functions unique to tandem mass spectrometry (MS/MS) mode of data acquisition, such as precursor ion scan (PIS) and neutral loss scan (NLS), are important for selective extraction of key structural data from complex MS/MS spectra. However, their software counterparts, software ion scan (SIS) functions, are still not regularly available. Software ion scan functions can be easily coded for additional functionalities, such as software multiple precursor ion scan, software no ion scan, and software variable ion scan functions. These are often necessary, since they allow more efficient analysis of complex MS/MS datasets, often encountered in glycomics and lipidomics. Software ion scan functions can be easily coded by using modern script languages and can be independent of instrument manufacturer. Here we demonstrate the utility of SIS functions on a medium-size glycomic MS/MS dataset. Knowledge of sample properties, as well as of diagnostic and conditional diagnostic ions crucial for data analysis, was needed. Based on the tables constructed with the output data from the SIS functions performed, a detailed analysis of a complex MS/MS glycomic dataset could be carried out in a quick, accurate, and efficient manner. Glycomic research is progressing slowly, and with respect to the MS experiments, one of the key obstacles for moving forward is the lack of appropriate bioinformatic tools necessary for fast analysis of glycomic MS/MS datasets. Adding novel SIS functionalities to the glycomic MS/MS toolbox has a potential to significantly speed up the glycomic data analysis process. Similar tools are useful for analysis of lipidomic MS/MS datasets as well, as will be discussed briefly. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Post-acquisition data mining techniques for LC-MS/MS-acquired data in drug metabolite identification.

    Science.gov (United States)

    Dhurjad, Pooja Sukhdev; Marothu, Vamsi Krishna; Rathod, Rajeshwari

    2017-08-01

    Metabolite identification is a crucial part of the drug discovery process. LC-MS/MS-based metabolite identification has gained widespread use, but the data acquired by the LC-MS/MS instrument is complex, and thus the interpretation of data becomes troublesome. Fortunately, advancements in data mining techniques have simplified the process of data interpretation with improved mass accuracy and provide a potentially selective, sensitive, accurate and comprehensive way for metabolite identification. In this review, we have discussed the targeted (extracted ion chromatogram, mass defect filter, product ion filter, neutral loss filter and isotope pattern filter) and untargeted (control sample comparison, background subtraction and metabolomic approaches) post-acquisition data mining techniques, which facilitate the drug metabolite identification. We have also discussed the importance of integrated data mining strategy.

  17. Use of a MS-electronic nose for prediction of early fungal spoilage of bakery products.

    Science.gov (United States)

    Marín, S; Vinaixa, M; Brezmes, J; Llobet, E; Vilanova, X; Correig, X; Ramos, A J; Sanchis, V

    2007-02-28

    A MS-based electronic nose was used to detect fungal spoilage (measured as ergosterol concentration) in samples of bakery products. Bakery products were inoculated with different Eurotium, Aspergillus and Penicillium species, incubated in sealed vials and their headspace sampled after 2, 4 and 7 days. Once the headspace was sampled, ergosterol content was determined in each sample. Different electronic nose signals were recorded depending on incubation time. Both the e-nose signals and ergosterol levels were used to build models for prediction of ergosterol content using e-nose measurements. Accuracy on prediction of those models was between 87 and 96%, except for samples inoculated with Penicillium corylophilum where the best predictions only reached 46%.

  18. Screening instruments for predicting return to work in long-term sickness absence

    DEFF Research Database (Denmark)

    Momsen, A-M H; Stapelfeldt, C M; Nielsen, C V

    2017-01-01

    Background: Multiple somatic symptoms are common and may cause prolonged sickness absence (SA) and unsuccessful return to work (RTW). Aims: To compare three instruments and their predictive and discriminative abilities regarding RTW. Methods: A longitudinal cohort study of participants recruited...

  19. Subnanogram proteomics: Impact of LC column selection, MS instrumentation and data analysis strategy on proteome coverage for trace samples

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Ying; Zhao, Rui; Piehowski, Paul D.; Moore, Ronald J.; Lim, Sujung; Orphan, Victoria J.; Paša-Tolić, Ljiljana; Qian, Wei-Jun; Smith, Richard D.; Kelly, Ryan T.

    2018-04-01

    One of the greatest challenges for mass spectrometry (MS)-based proteomics is the limited ability to analyze small samples. Here we investigate the relative contributions of liquid chromatography (LC), MS instrumentation and data analysis methods with the aim of improving proteome coverage for sample sizes ranging from 0.5 ng to 50 ng. We show that the LC separations utilizing 30-µm-i.d. columns increase signal intensity by >3-fold relative to those using 75-µm-i.d. columns, leading to 32% increase in peptide identifications. The Orbitrap Fusion Lumos mass spectrometer significantly boosted both sensitivity and sequencing speed relative to earlier generation Orbitraps (e.g., LTQ-Orbitrap), leading to a ~3× increase in peptide identifications and 1.7× increase in identified protein groups for 2 ng tryptic digests of bacterial lysate. The Match Between Runs algorithm of open-source MaxQuant software further increased proteome coverage by ~ 95% for 0.5 ng samples and by ~42% for 2 ng samples. The present platform is capable of identifying >3000 protein groups from tryptic digestion of cell lysates equivalent to 50 HeLa cells and 100 THP-1 cells (~10 ng total proteins), respectively, and >950 proteins from subnanogram bacterial and archaeal cell lysates. The present ultrasensitive LC-MS platform is expected to enable deep proteome coverage for subnanogram samples, including single mammalian cells.

  20. Accurate determination of ultra-trace levels of Ti in blood serum using ICP-MS/MS

    International Nuclear Information System (INIS)

    Balcaen, Lieve; Bolea-Fernandez, Eduardo; Resano, Martín; Vanhaecke, Frank

    2014-01-01

    Graphical abstract: -- Highlights: •Novel method for determination of Ti at ultra-trace levels in clinical samples (serum). •Novel method based on Ti(NH 3 ) 6 + reaction product ion formation and double mass selection using recently introduced ICP-QQQ instrumentation. •Lowest limits of detection ever obtained using quadrupole-based instrumentation for Ti. •Accurate determination of basal levels of Ti in blood serum. -- Abstract: Ti is frequently used in implants and prostheses and it has been shown before that the presence of these in the human body can lead to elevated Ti concentrations in body fluids such as serum and urine. As identification of the exact mechanisms responsible for this increase in Ti concentrations, and the risks associated with it, are not fully understood, it is important to have sound analytical methods that enable straightforward quantification of Ti levels in body fluids (for both implanted and non-implanted individuals). Until now, only double-focusing sector field ICP-mass spectrometry (SF-ICP-MS) offered limits of detection that are good enough to deal with the very low basal levels of Ti in human serum. This work reports on the development of a novel method for the accurate and precise determination of trace levels of Ti in human serum samples, based on the use of ICP-MS/MS. O 2 and NH 3 /He have been compared as reaction gases. While the use of O 2 did not enable to overcome all spectral interferences, it has been shown that conversion of Ti + ions into Ti(NH 3 ) 6 + cluster ions by using NH 3 /He as a reaction gas in an ICP-QQQ-MS system, operated in MS/MS mode, provided interference-free conditions and sufficiently low limits of detection, down to 3 ng L −1 (instrumental detection limit obtained for the most abundant Ti isotope). The accuracy of the method proposed was evaluated by analysis of a Seronorm Trace Elements Serum L-1 reference material and by comparing the results obtained with those achieved by means of SF-ICP-MS

  1. Characterization, stoichiometry, and stability of salivary protein-tannin complexes by ESI-MS and ESI-MS/MS.

    Science.gov (United States)

    Canon, Francis; Paté, Franck; Meudec, Emmanuelle; Marlin, Thérèse; Cheynier, Véronique; Giuliani, Alexandre; Sarni-Manchado, Pascale

    2009-12-01

    Numerous protein-polyphenol interactions occur in biological and food domains particularly involving proline-rich proteins, which are representative of the intrinsically unstructured protein group (IUP). Noncovalent protein-ligand complexes are readily detected by electrospray ionization mass spectrometry (ESI-MS), which also gives access to ligand binding stoichiometry. Surprisingly, the study of interactions between polyphenolic molecules and proteins is still an area where ESI-MS has poorly benefited, whereas it has been extensively applied to the detection of noncovalent complexes. Electrospray ionization mass spectrometry has been applied to the detection and the characterization of the complexes formed between tannins and a human salivary proline-rich protein (PRP), namely IB5. The study of the complex stability was achieved by low-energy collision-induced dissociation (CID) measurements, which are commonly implemented using triple quadrupole, hybrid quadrupole time-of-flight, or ion trap instruments. Complexes composed of IB5 bound to a model polyphenol EgCG have been detected by ESI-MS and further analyzed by MS/MS. Mild ESI interface conditions allowed us to observe intact noncovalent PRP-tannin complexes with stoichiometries ranging from 1:1 to 1:5. Thus, ESI-MS shows its efficiency for (1) the study of PRP-tannin interactions, (2) the determination of stoichiometry, and (3) the study of complex stability. We were able to establish unambiguously both their stoichiometries and their overall subunit architecture via tandem mass spectrometry and solution disruption experiments. Our results prove that IB5.EgCG complexes are maintained intact in the gas phase.

  2. Liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) based bioavailability determination of the major classes of phytochemicals.

    Science.gov (United States)

    Stylos, Evgenios; Chatziathanasiadou, Maria V; Syriopoulou, Aggeliki; Tzakos, Andreas G

    2017-03-15

    Natural products derived from plants have served as an inexhausted source for drug discovery and drug development. They have been evolutionary amplified with drug-like properties and have already illustrated immense therapeutic potential over an array of different diseases. However, their incorporation in the drug discovery pipeline has been diminished the last two decades. This was probably due to barriers related to their inherent difficulties to be integrated in high-throughput screening assays as also their largely unexplored bioavailability. Analytical procedures have come into the spotlight, a result of the continuous development of the instrumentation's capabilities as far as detection and separation is concerned. Integral part of this technological evolution is LC-MS instrumentation and its extended use for the determination of various compounds. The fact that it provides extra sensitivity, specificity and good separation in complex samples, makes LC-MS/MS the ultimate tool in the determination of many types of chemical compounds, such as phytochemicals. Herein, we focus on the achievements of the last five years in quantitative analysis of the major classes of phytochemicals (flavonoids, alkaloids, terpenes, glycosides and saponins) in plasma, through LC-MS/MS, as also their bioavailability. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. The Utility of Risk Assessment Instruments for the Prediction of Recidivism in Sexual Homicide Perpetrators

    Science.gov (United States)

    Hill, Andreas; Rettenberger, Martin; Habermann, Niels; Berner, Wolfgang; Eher, Reinhard; Briken, Peer

    2012-01-01

    To examine the predictive accuracy of four well established risk assessment instruments (PCL-R, HCR-20, SVR-20, and Static-99) in an important subgroup of sexual offenders, these instruments were assessed retrospectively based on information from forensic psychiatric court reports in a sample of 90 released male sexual homicide offenders (out of…

  4. Multivariate DoE Optimization of Asymmetric Flow Field Flow Fractionation Coupled to Quantitative LC-MS/MS for Analysis of Lipoprotein Subclasses

    Directory of Open Access Journals (Sweden)

    Zsuzsanna Kuklenyik

    2015-02-01

    Full Text Available In this report we demonstrate a practical multivariate design of experiment (DoE approach for asymmetric flow field-flow fractionation (AF4 method optimization using separation of lipoprotein subclasses as an example. First, with the aid of commercially available software, we built a full factorial screening design where the theoretical outcomes were calculated by applying established formulas that govern AF4 channel performance for a 5–35 nm particle size range of interest for lipid particles. Second, using the desirable ranges of instrumental parameters established from theoretical optimization, we performed fractional factorial DoE for AF4 separation of pure albumin and ferritin with UV detection to narrow the range of instrumental parameters and allow optimum size resolution while minimizing losses from membrane immobilization. Third, the optimal range of conditions were tested using response surface DoE for sub-fractionation of high and low density lipoproteins (HDL and LDL in human serum, where the recovery of the analytes were monitored by fraction collection and isotope-dilution LC-MS/MS analysis of each individual fraction for cholesterol and apolipoproteins (ApoA-1 and ApoB-100. Our results show that DoE is an effective tool in combining AF4 theoretical knowledge and experimental data in finding the most optimal set of AF4 instrumental parameters for quantitative coupling with LC-MS/MS measurements.

  5. CE-TOF/MS: fundamental concepts, instrumental considerations and applications.

    Science.gov (United States)

    Staub, Aline; Schappler, Julie; Rudaz, Serge; Veuthey, Jean-Luc

    2009-05-01

    This review discusses the fundamental principles of TOF analyzers and covers the great progress that has been made in this area in recent years (i.e. orthogonal acceleration, reflectron). This paper also gives an overview of applications performed by CE coupled to TOF/MS detection. The main domains of interest include the analysis of biomolecules and natural compounds.

  6. The Symbol Digit Modalities Test is an effective cognitive screen in pediatric onset multiple sclerosis (MS).

    Science.gov (United States)

    Charvet, Leigh E; Beekman, Rachel; Amadiume, Nneka; Belman, Anita L; Krupp, Lauren B

    2014-06-15

    To evaluate the Symbol Digit Modalities Test (SDMT) as a tool for identifying pediatric-onset MS patients at risk for cognitive impairment. The SDMT is a brief measure of cognitive processing speed that is often used in adult MS patients. Approximately one-third of pediatric-onset MS patients have cognitive impairment and there is a need for an effective screening instrument. Seventy (70) consecutive outpatients with pediatric-onset MS underwent clinical evaluations including the SDMT and were compared to those with other pediatric neurological diagnoses (OND, n=40) and healthy controls (HC, n=32). A subset of the MS group and all healthy controls completed neuropsychological evaluation within one year of SDMT administration. The MS group performed worse on the SDMT compared to the HC group (p=0.02). Thirty-seven percent (37%) of the MS, 20% of the OND, and 9% of HC groups scored in the impaired range. For MS participants who underwent neuropsychological testing (n=31), the SDMT showed 77% sensitivity and 81% specificity for detecting neuropsychological impairment when administered within one year and reached 100% sensitivity when the interval was under two months (n=17). Overall, older age and increased disability predicted poorer SDMT performance (age r=-0.26, p=0.03) and the Expanded Disability Status Scale score or EDSS (r=-0.47, pMS. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. PyMS: a Python toolkit for processing of gas chromatography-mass spectrometry (GC-MS data. Application and comparative study of selected tools

    Directory of Open Access Journals (Sweden)

    O'Callaghan Sean

    2012-05-01

    Full Text Available Abstract Background Gas chromatography–mass spectrometry (GC-MS is a technique frequently used in targeted and non-targeted measurements of metabolites. Most existing software tools for processing of raw instrument GC-MS data tightly integrate data processing methods with graphical user interface facilitating interactive data processing. While interactive processing remains critically important in GC-MS applications, high-throughput studies increasingly dictate the need for command line tools, suitable for scripting of high-throughput, customized processing pipelines. Results PyMS comprises a library of functions for processing of instrument GC-MS data developed in Python. PyMS currently provides a complete set of GC-MS processing functions, including reading of standard data formats (ANDI- MS/NetCDF and JCAMP-DX, noise smoothing, baseline correction, peak detection, peak deconvolution, peak integration, and peak alignment by dynamic programming. A novel common ion single quantitation algorithm allows automated, accurate quantitation of GC-MS electron impact (EI fragmentation spectra when a large number of experiments are being analyzed. PyMS implements parallel processing for by-row and by-column data processing tasks based on Message Passing Interface (MPI, allowing processing to scale on multiple CPUs in distributed computing environments. A set of specifically designed experiments was performed in-house and used to comparatively evaluate the performance of PyMS and three widely used software packages for GC-MS data processing (AMDIS, AnalyzerPro, and XCMS. Conclusions PyMS is a novel software package for the processing of raw GC-MS data, particularly suitable for scripting of customized processing pipelines and for data processing in batch mode. PyMS provides limited graphical capabilities and can be used both for routine data processing and interactive/exploratory data analysis. In real-life GC-MS data processing scenarios PyMS performs

  8. Predictive factors for the success of McRoberts' manoeuvre and suprapubic pressure in relieving shoulder dystocia: a cross-sectional study.

    Science.gov (United States)

    Lok, Zara Lin Zau; Cheng, Yvonne Kwun Yue; Leung, Tak Yeung

    2016-10-29

    McRoberts' and suprapubic pressure are often recommended as the initial choices of manoeuvres to manage shoulder dystocia, as they are believed to be less invasive compared to other manoeuvres. However, their success rates range from 23 to 40 %. This study aims to investigate the predictive factors for the success of McRoberts' manoeuvre with or without suprapubic pressure (M+/-S). All cases of shoulder dystocia in a tertiary hospital in South East Asia were recruited from 1995 to 2009. Subjects were analysed according to either 'success' or 'failure' of M+/-S. Maternal and fetal antenatal and intrapartum factors were compared by univariate and multivariate analysis. Among 198 cases of shoulder dystocia, M+/-S as the primary manoeuvre was successful in 25.8 %. The other 74.2 % needed either rotational or posterior arm manoeuvres or combination of manoeuvres. Instrumental delivery was the single most significant factor associated with an increased risk of failed M+/-S on logistic regression (p dystocia occurred after instrumental delivery but was 47.7 % after spontaneous vaginal delivery. When shoulder dystocia occurs after instrumental vaginal delivery, the chance of failure of M+/-S is 85 %, which is 4.7 times higher than that after spontaneous vaginal delivery. Hence all operators performing instrumental delivery should be proficient in performing all manoeuvres to relieve shoulder dystocia when M+/-S cannot do so.

  9. Interaction of Instrumental and Goal-Directed Learning Modulates Prediction Error Representations in the Ventral Striatum.

    Science.gov (United States)

    Guo, Rong; Böhmer, Wendelin; Hebart, Martin; Chien, Samson; Sommer, Tobias; Obermayer, Klaus; Gläscher, Jan

    2016-12-14

    Goal-directed and instrumental learning are both important controllers of human behavior. Learning about which stimulus event occurs in the environment and the reward associated with them allows humans to seek out the most valuable stimulus and move through the environment in a goal-directed manner. Stimulus-response associations are characteristic of instrumental learning, whereas response-outcome associations are the hallmark of goal-directed learning. Here we provide behavioral, computational, and neuroimaging results from a novel task in which stimulus-response and response-outcome associations are learned simultaneously but dominate behavior at different stages of the experiment. We found that prediction error representations in the ventral striatum depend on which type of learning dominates. Furthermore, the amygdala tracks the time-dependent weighting of stimulus-response versus response-outcome learning. Our findings suggest that the goal-directed and instrumental controllers dynamically engage the ventral striatum in representing prediction errors whenever one of them is dominating choice behavior. Converging evidence in human neuroimaging studies has shown that the reward prediction errors are correlated with activity in the ventral striatum. Our results demonstrate that this region is simultaneously correlated with a stimulus prediction error. Furthermore, the learning system that is currently dominating behavioral choice dynamically engages the ventral striatum for computing its prediction errors. This demonstrates that the prediction error representations are highly dynamic and influenced by various experimental context. This finding points to a general role of the ventral striatum in detecting expectancy violations and encoding error signals regardless of the specific nature of the reinforcer itself. Copyright © 2016 the authors 0270-6474/16/3612650-11$15.00/0.

  10. A Parsimonious Instrument for Predicting Students' Intent to Pursue a Sales Career: Scale Development and Validation

    Science.gov (United States)

    Peltier, James W.; Cummins, Shannon; Pomirleanu, Nadia; Cross, James; Simon, Rob

    2014-01-01

    Students' desire and intention to pursue a career in sales continue to lag behind industry demand for sales professionals. This article develops and validates a reliable and parsimonious scale for measuring and predicting student intention to pursue a selling career. The instrument advances previous scales in three ways. The instrument is…

  11. A comparison of the predictive properties of nine sex offender risk assessment instruments

    NARCIS (Netherlands)

    Smid, W.J.; Kamphuis, J.H.; Wever, E.C.; van Beek, D.J.

    2014-01-01

    Sex offender treatment is most effective when tailored to risk-need-responsivity principles, which dictate that treatment levels should match risk levels as assessed by structured risk assessment instruments. The predictive properties, missing values, and interrater agreement of the scores of 9

  12. Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control.

    Science.gov (United States)

    Cha, Eunju; Kim, Sohee; Kim, Ho Jun; Lee, Kang Mi; Kim, Ki Hun; Kwon, Oh-Seung; Lee, Jaeick

    2015-01-01

    This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Study of the performance of three LC-MS/MS platforms for analysis of perfluorinated compounds

    Energy Technology Data Exchange (ETDEWEB)

    Llorca, Marta; Farre, Marinella [IDAEA-CSIC, Department of Environmental Chemistry, Barcelona (Spain); Pico, Yolanda [Universitat de Valencia, Laboratori de Nutricio i Bromatologia, Facultat de Farmacia, Burjassot, Valencia (Spain); Barcelo, Damia [IDAEA-CSIC, Department of Environmental Chemistry, Barcelona (Spain); King Saud University, Riyadh (Saudi Arabia)

    2010-10-15

    The analytical suitabilities of three different liquid chromatography-tandem mass spectrometry (LC-MS/MS) systems, (1) triple quadrupole (QqQ), (2) conventional 3D ion trap (IT), and (3) quadrupole-linear IT (QqLIT), to determine trace levels of perfluorinated compounds (PFCs) in fish and shellfish were compared. Sample preparation was performed using alkaline extraction and solid-phase-extraction cleanup. This evaluation was focused on both quantitative (sensitivity, precision, and accuracy) and qualitative (identification capabilities) aspects. In the three instruments, the former facet was evaluated using selected reaction monitoring (SRM), which is the standard mode for quantitative LC-MS/MS analysis. Accuracy was similar in the three systems, with recoveries always over 70 %. Precision was better for the QqLIT and QqQ systems (7-15%) than for the IT system (10-17%). The QqLIT (working in SRM mode) and QqQ systems offered a linear dynamic range of at least 3 orders of magnitude, whereas that of the IT system was 2 orders of magnitude. The QqLIT system achieved at least 20-fold higher sensitivity than the QqQ system, and this was at least tenfold higher sensitivity than for the IT system. In the IT system, identification was based on sensitive full mass range acquisition and MS{sup n} fragmentation and in the QqLIT system, it was based on the use of an information-dependent-acquisition scan function, which allows the combination of an SRM or MS full scan acting as the survey scan and an enhanced product ion scan followed by MS{sup 3} as the dependent scan in the same analysis. Three instruments were applied to monitor the content in fish and shellfish (anchovies, swordfish, tuna, mussels, and oysters) obtained from Valencia and Barcelona markets (Spain). The eight target PFCs were detected at mean concentrations in the range from 10 ng kg {sup -1} (perfluoro-7-methyloctanoic acid and perfluoro-1-decanesulfonate) to 4,200 ng kg {sup -1} (perfluoropentanoic acid

  14. Recent advances in CE-MS coupling: Instrumentation, methodology, and applications

    Czech Academy of Sciences Publication Activity Database

    Týčová, Anna; Ledvina, Vojtěch; Klepárník, Karel

    2017-01-01

    Roč. 38, č. 1 (2017), s. 115-134 ISSN 0173-0835 R&D Projects: GA ČR(CZ) GA14-28254S Institutional support: RVO:68081715 Keywords : CE * electrospray * MS * microfluidic devices Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 2.744, year: 2016

  15. Precise and accurate isotope ratio measurements by ICP-MS.

    Science.gov (United States)

    Becker, J S; Dietze, H J

    2000-09-01

    The precise and accurate determination of isotope ratios by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) is important for quite different application fields (e.g. for isotope ratio measurements of stable isotopes in nature, especially for the investigation of isotope variation in nature or age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, quality assurance of fuel material, for reprocessing plants, nuclear material accounting and radioactive waste control, for tracer experiments using stable isotopes or long-lived radionuclides in biological or medical studies). Thermal ionization mass spectrometry (TIMS), which used to be the dominant analytical technique for precise isotope ratio measurements, is being increasingly replaced for isotope ratio measurements by ICP-MS due to its excellent sensitivity, precision and good accuracy. Instrumental progress in ICP-MS was achieved by the introduction of the collision cell interface in order to dissociate many disturbing argon-based molecular ions, thermalize the ions and neutralize the disturbing argon ions of plasma gas (Ar+). The application of the collision cell in ICP-QMS results in a higher ion transmission, improved sensitivity and better precision of isotope ratio measurements compared to quadrupole ICP-MS without the collision cell [e.g., for 235U/238U approximately 1 (10 microg x L(-1) uranium) 0.07% relative standard deviation (RSD) vs. 0.2% RSD in short-term measurements (n = 5)]. A significant instrumental improvement for ICP-MS is the multicollector device (MC-ICP-MS) in order to obtain a better precision of isotope ratio measurements (with a precision of up to 0.002%, RSD). CE- and HPLC-ICP-MS are used for the separation of isobaric interferences of long-lived radionuclides and stable isotopes by determination of spallation nuclide abundances in an irradiated tantalum target.

  16. Distinctive and Complementary MS2 Fragmentation Characteristics for Identification of Sulfated Sialylated N-Glycopeptides by nanoLC-MS/MS Workflow

    Science.gov (United States)

    Kuo, Chu-Wei; Guu, Shih-Yun; Khoo, Kay-Hooi

    2018-04-01

    High sensitivity identification of sulfated glycans carried on specific sites of glycoproteins is an important requisite for investigation of molecular recognition events involved in diverse biological processes. However, aiming for resolving site-specific glycosylation of sulfated glycopeptides by direct LC-MS2 sequencing is technically most challenging. Other than the usual limiting factors such as lower abundance and ionization efficiency compared to analysis of non-glycosylated peptides, confident identification of sulfated glycopeptides among the more abundant non-sulfated glycopeptides requires additional considerations in the selective enrichment and detection strategies. Metal oxide has been applied to enrich phosphopeptides and sialylated glycopeptides, but its use to capture sulfated glycopeptides has not been investigated. Likewise, various complementary MS2 fragmentation modes have yet to be tested against sialylated and non-sialylated sulfoglycopeptides due to limited appropriate sample availability. In this study, we have investigated the feasibility of sequencing tryptic sulfated N-glycopeptide and its MS2 fragmentation characteristics by first optimizing the enrichment methods to allow efficient LC-MS detection and MS2 analysis by a combination of CID, HCD, ETD, and EThcD on hybrid and tribrid Orbitrap instruments. Characteristic sulfated glyco-oxonium ions and direct loss of sulfite from precursors were detected as evidences of sulfate modification. It is anticipated that the technical advances demonstrated in this study would allow a feasible extension of our sulfoglycomic analysis to sulfoglycoproteomics. [Figure not available: see fulltext.

  17. Inter-laboratory evaluation of instrument platforms and experimental workflows for quantitative accuracy and reproducibility assessment

    Directory of Open Access Journals (Sweden)

    Andrew J. Percy

    2015-09-01

    Full Text Available The reproducibility of plasma protein quantitation between laboratories and between instrument types was examined in a large-scale international study involving 16 laboratories and 19 LC–MS/MS platforms, using two kits designed to evaluate instrument performance and one kit designed to evaluate the entire bottom-up workflow. There was little effect of instrument type on the quality of the results, demonstrating the robustness of LC/MRM-MS with isotopically labeled standards. Technician skill was a factor, as errors in sample preparation and sub-optimal LC–MS performance were evident. This highlights the importance of proper training and routine quality control before quantitation is done on patient samples.

  18. Microdose study of a P-glycoprotein substrate, fexofenadine, using a non-radioisotope-labelled drug and LC/MS/MS.

    Science.gov (United States)

    Yamazaki, A; Kumagai, Y; Yamane, N; Tozuka, Z; Sugiyama, Y; Fujita, T; Yokota, S; Maeda, M

    2010-04-01

    Fexofenadine is a P-glycoprotein substrate of low bioavailability. It is primarily excreted into faeces as a parent drug via biliary excretion. The predictability from microdose data for the drug absorbed via transporters such as P-glycoprotein is not known. Therefore, this study assessed the predictability of therapeutic-dose pharmacokinetics of fexofenadine from microdosing data using non-radioisotope-labelled drug and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS). In a single dose, randomized, two-way crossover study, eight subjects received a microdose (100 microg) or a therapeutic dose (60 mg) of fexofenadine. Blood samples were collected until 12 h after dosing, and assayed using LC/MS/MS. Plasma concentration-time curves of fexofenadine between microdose and therapeutic dose were similar. The mean +/- SD of C(max) normalized to 60 mg dose after microdose and therapeutic dose were 379 +/- 147 and 275 +/- 145 ng/mL respectively. The mean AUC(last) normalized to 60 mg dose after microdose and therapeutic dose were 1914 +/- 738 and 1431 +/- 432 ng/h/mL respectively. The mean dose-adjusted C(max) and AUC(last) after microdose were higher compared with those after therapeutic dose. Individual plots of C(max) and AUC(last) normalized to 60 mg dose, were similar for microdose and therapeutic dose. None of the pharmacokinetic parameters were statistically different using anova. Overall, the microdose pharmacokinetics profile was similar to, and hence predictive of, that of the therapeutic dose. For the P-glycoprotein substrate fexofenadine, the predictability of therapeutic-dose pharmacokinetics from microdose data was good. A microdose study using a non-radioisotope-labelled drug and LC/MS/MS is convenient, and has the potential to aid the early selection of drug candidates.

  19. Development of a plug-type IMS-MS instrument and its applications in resolving problems existing in in-situ detection of illicit drugs and explosives by IMS.

    Science.gov (United States)

    Du, Zhenxia; Sun, Tangqiang; Zhao, Jianan; Wang, Di; Zhang, Zhongxia; Yu, Wenlian

    2018-07-01

    Ion mobility spectrometry (IMS) which acts as a rapid analysis technique is widely used in the field detection of illicit drugs and explosives. Due to limited separation abilities of the pint-sized IMS challenges and problems still exist regarding high false positive and false negative responses due to the interference of the matrix. In addition, the gas-phase ion chemistry and special phenomena in the IMS spectra, such one substance showing two peaks, were not identified unambiguously. In order to explain or resolve these questions, in this paper, an ion mobility spectrometry was coupled to a mass spectrometry (IMS-MS). A commercial IMS is embedded in a custom-built ion chamber shell was attached to the mass spectrometer. The faraday plate of IMS was fabricated with a hole for the ions to passing through to the mass spectrometer. The ion transmission efficiency of IMS-MS was optimized by optimizing the various parameters, especially the distance between the faraday plate and the cone of mass spectrum. This design keeps the integrity of the two original instruments and the mass spectrometry still works with multimode ionization source (i.e., IMS-MS, ESI-MS, APCI-MS modes). The illicit drugs and explosive samples were analyzed by the IMS-MS with 63 Ni source. The results showed that the IMS-MS is of high sensitivity. The ionization mechanism of the illicit drug and explosive samples with 63 Ni source were systematically studied. In addition, the interferent which interfered the detection of cocaine was identified as dibutyl phthalate (DBP) by this platform. The reason why the acetone solution of amphetamine showed two peaks was explained. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Screening for frailty in community-dwelling elderly subjects: Predictive validity of the modified SEGA instrument.

    Science.gov (United States)

    Oubaya, N; Dramé, M; Novella, J-L; Quignard, E; Cunin, C; Jolly, D; Mahmoudi, R

    2017-11-01

    To study the capacity of the SEGAm instrument to predict loss of independence among elderly community-dwelling subjects. The study was performed in four French departments (Ardennes, Marne, Meurthe-et-Moselle, Meuse). Subjects aged 65 years or more, living at home, who could read and understand French, with a degree of autonomy corresponding to groups 5 or 6 in the AGGIR autonomy evaluation scale were included. Assessment included demographic characteristics, comprehensive geriatric assessment, and the SEGAm instrument at baseline. Subjects had follow-up visits at home at 6 and 12 months. During follow-up, vital status and level of independence were recorded. Logistic regression was used to study predictive validity of the SEGAm instrument. Among the 116 subjects with complete follow-up, 84 (72.4%) were classed as not very frail at baseline, 23 (19.8%) as frail, and 9 (7.8%) as very frail; 63 (54.3%) suffered loss of at least one ADL or IADL at 12 months. By multivariable analysis, frailty status at baseline was significantly associated with loss of independence during the 12 months of follow-up (OR=4.52, 95% CI=1.40-14.68; p=0.01). We previously validated the SEGAm instrument in terms of feasibility, acceptability, internal structure validity, reliability, and discriminant validity. This instrument appears to be a suitable tool for screening frailty among community-dwelling elderly subjects, and could be used as a basis to plan early targeted interventions for subjects at risk of adverse outcome. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Market Research Survey of Commercial Off-The-Shelf (COTS) Portable MS Systems for IAEA Safeguards Applications

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Garret L.; Hager, George J.; Barinaga, Charles J.; Duckworth, Douglas C.

    2013-02-01

    This report summarizes the results for the market research survey of mass spectrometers that are deemed pertinent to International Atomic Energy Agency (IAEA) needs and strategic objectives. The focus of the report is on MS instruments that represent currently available (or soon to be) commercial off-the shelf (COTS) technology and weigh less than 400 pounds. A compilation of all available MS instruments (36 COTS and 2 R&D) is presented, along with pertinent information regarding each instrument.

  2. A novel study of screening and confirmation of modafinil, adrafinil and their metabolite modafinilic acid under EI-GC-MS and ESI-LC-MS-MS ionization.

    Science.gov (United States)

    Dubey, S; Ahi, S; Reddy, I M; Kaur, T; Beotra, A; Jain, S

    2009-12-01

    Adrafinil and modafinil have received wide publicity and have become controversial in the sporting world when several athletes were discovered allegedly using these drugs as doping agents. By acknowledging the facts, the World Anti-Doping Agency (WADA) banned these drugs in sports since 2004. The present study explores the possibility of differentiating adrafinil and modafinil and their major metabolites under electron impact ionization in gas chromatograph-mass spectrometer (GC-MSD) and electrospray ionization in liquid chromatograph-mass spectrometer (LC-MS/MS) by studying the fragmentation pattern of these drugs. Adrafinil, modafinil and their major metabolite, modafinilic acid were analyzed on EI-GC-MSD and ESI-LC-MS/MS using various individual parameters on both the instruments. The analytical technique and equipment used in the analysis were an Agilent 6890N GC with 5973 mass selective detector for the GC-MSD analysis and an Agilent 1100 HPLC with API-3200 Triple quadrupole mass spectrometer for the LC-MS/MS analysis. Validation of both methods was performed using six replicates at different concentrations. The results show that adrafinil, modafinil and their major metabolite modafinilic acid could be detected as a single artifact without differentiation under EI-GC-MSD analysis. However, all drugs could be detected and differentiated under ESI-LCMS/MS analysis without any artifaction. The GC-MSD analysis gives a single artifact for both the drugs without differentiation and thus can be used as a marker for screening purposes. Further, the Multiple Reaction Monitoring (MRM) method developed under LC-MS/MS is fit for the purpose for confirmation of suspicious samples in routine sports testing and in forensic and clinical analysis.

  3. Cost prediction model for various payloads and instruments for the Space Shuttle Orbiter

    Science.gov (United States)

    Hoffman, F. E.

    1984-01-01

    The following cost parameters of the space shuttle were undertaken: (1) to develop a cost prediction model for various payload classes of instruments and experiments for the Space Shuttle Orbiter; and (2) to show the implications of various payload classes on the cost of: reliability analysis, quality assurance, environmental design requirements, documentation, parts selection, and other reliability enhancing activities.

  4. Proteomic biomarkers predicting lymph node involvement in serum of cervical cancer patients. Limitations of SELDI-TOF MS

    Directory of Open Access Journals (Sweden)

    Van Gorp Toon

    2012-06-01

    Full Text Available Abstract Background Lymph node status is not part of the staging system for cervical cancer, but provides important information for prognosis and treatment. We investigated whether lymph node status can be predicted with proteomic profiling. Material & methods Serum samples of 60 cervical cancer patients (FIGO I/II were obtained before primary treatment. Samples were run through a HPLC depletion column, eliminating the 14 most abundant proteins ubiquitously present in serum. Unbound fractions were concentrated with spin filters. Fractions were spotted onto CM10 and IMAC30 surfaces and analyzed with surface-enhanced laser desorption time of flight (SELDI-TOF mass spectrometry (MS. Unsupervised peak detection and peak clustering was performed using MASDA software. Leave-one-out (LOO validation for weighted Least Squares Support Vector Machines (LSSVM was used for prediction of lymph node involvement. Other outcomes were histological type, lymphvascular space involvement (LVSI and recurrent disease. Results LSSVM models were able to determine LN status with a LOO area under the receiver operating characteristics curve (AUC of 0.95, based on peaks with m/z values 2,698.9, 3,953.2, and 15,254.8. Furthermore, we were able to predict LVSI (AUC 0.81, to predict recurrence (AUC 0.92, and to differentiate between squamous carcinomas and adenocarcinomas (AUC 0.88, between squamous and adenosquamous carcinomas (AUC 0.85, and between adenocarcinomas and adenosquamous carcinomas (AUC 0.94. Conclusions Potential markers related with lymph node involvement were detected, and protein/peptide profiling support differentiation between various subtypes of cervical cancer. However, identification of the potential biomarkers was hampered by the technical limitations of SELDI-TOF MS.

  5. ToF-SIMS Parallel Imaging MS/MS of Lipid Species in Thin Tissue Sections.

    Science.gov (United States)

    Bruinen, Anne Lisa; Fisher, Gregory L; Heeren, Ron M A

    2017-01-01

    Unambiguous identification of detected species is essential in complex biomedical samples. To date, there are not many mass spectrometry imaging techniques that can provide both high spatial resolution and identification capabilities. A new and patented imaging tandem mass spectrometer, exploiting the unique characteristics of the nanoTOF II (Physical Electronics, USA) TOF-SIMS TRIFT instrument, was developed to address this.Tandem mass spectrometry is based on the selection of precursor ions from the full secondary ion spectrum (MS 1 ), followed by energetic activation and fragmentation, and collection of the fragment ions to obtain a tandem MS spectrum (MS 2 ). The PHI NanoTOF II mass spectrometer is equipped with a high-energy collision induced dissociation (CID) fragmentation cell as well as a second time-of-flight analyzer developed for simultaneous ToF-SIMS and tandem MS imaging experiments.We describe here the results of a ToF-SIMS imaging experiment on a thin tissue section of an infected zebrafish as a model organism for tuberculosis. The focus is on the obtained ion distribution plot of a fatty acid as well as its identification by tandem mass spectrometry.

  6. Evaluation of laser diode thermal desorption-tandem mass spectrometry (LDTD-MS-MS) in forensic toxicology.

    Science.gov (United States)

    Bynum, Nichole D; Moore, Katherine N; Grabenauer, Megan

    2014-10-01

    Many forensic laboratories experience backlogs due to increased drug-related cases. Laser diode thermal desorption (LDTD) has demonstrated its applicability in other scientific areas by providing data comparable with instrumentation, such as liquid chromatography-tandem mass spectrometry, in less time. LDTD-MS-MS was used to validate 48 compounds in drug-free human urine and blood for screening or quantitative analysis. Carryover, interference, limit of detection, limit of quantitation, matrix effect, linearity, precision and accuracy and stability were evaluated. Quantitative analysis indicated that LDTD-MS-MS produced precise and accurate results with the average overall within-run precision in urine and blood represented by a %CV forensic toxicology but before it can be successfully implemented that there are some challenges that must be addressed. Although the advantages of the LDTD system include minimal maintenance and rapid analysis (∼10 s per sample) which makes it ideal for high-throughput forensic laboratories, a major disadvantage is its inability or difficulty analyzing isomers and isobars due to the lack of chromatography without the use of high-resolution MS; therefore, it would be best implemented as a screening technique. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Combined evaluation of personality, risk and coping in MS patients: A step towards individualized treatment choice - The PeRiCoMS-Study I.

    Science.gov (United States)

    Bsteh, G; Monz, E; Zamarian, L; Hagspiel, S; Hegen, H; Auer, M; Wurth, S; Di Pauli, F; Deisenhammer, F; Berger, T

    2017-05-15

    Multiple sclerosis (MS) is a chronic inflammatory neurological disease requiring disease-modifying treatment (DMT). To provide patients with the optimal individual therapeutic option, treatment recommendations should be based not only on individual disease course and DMT specific benefit-risk estimates, but also on patient's individual characteristics such as personality, risk attitude and coping strategies. However, these characteristics are difficult to objectify in clinical routine practice without the support of appropriate evaluation instruments. To identify and to assemble an objective test battery measuring personality, risk attitude and coping strategies in MS patients. A comprehensive literature search was performed to obtain all questionnaires assessing personality, risk attitude and coping strategies. Availability in German language, validation in a published normative collective and a reliability of >0.70 were required for our purposes. Based on these criteria, we chose the Big-Five-Personality Test, UPPS Impulsive Behaviour Scale, Domain-Specific Risk-Taking scale (DOSPERT), Brief-COPE and Stress & Coping Inventory (SCI). Results were compared to published normative controls of the respective questionnaires. Out of 22 MS patients (7 males, 15 females) participating in this study, 19 (86.4%) completed all questionnaires. The median completion time was 45min (min-max range: 25-60min). The median scores of the MS group were within the average range of published control samples in all questionnaires. We report that traits of personality, risk attitude and coping strategies can be effectively and feasibly tested in MS patients by the instruments used in our exploratory study. There were no differences between MS patients and healthy controls, thus enabling assessment without being influenced by the diagnosis of MS. After validation in a larger cohort the "PeRiCoMS"-battery will be useful as another step towards a more individualized shared

  8. Detection of Radiation-Exposure Biomarkers by Differential Mobility Prefiltered Mass Spectrometry (DMS-MS).

    Science.gov (United States)

    Coy, Stephen L; Krylov, Evgeny V; Schneider, Bradley B; Covey, Thomas R; Brenner, David J; Tyburski, John B; Patterson, Andrew D; Krausz, Kris W; Fornace, Albert J; Nazarov, Erkinjon G

    2010-04-15

    Technology to enable rapid screening for radiation exposure has been identified as an important need, and, as a part of a NIH / NIAD effort in this direction, metabolomic biomarkers for radiation exposure have been identified in a recent series of papers. To reduce the time necessary to detect and measure these biomarkers, differential mobility spectrometry - mass spectrometry (DMS-MS) systems have been developed and tested. Differential mobility ion filters preselect specific ions and also suppress chemical noise created in typical atmospheric-pressure ionization sources (ESI, MALDI, and others). Differential-mobility-based ion selection is based on the field dependence of ion mobility, which, in turn, depends on ion characteristics that include conformation, charge distribution, molecular polarizability, and other properties, and on the transport gas composition which can be modified to enhance resolution. DMS-MS is able to resolve small-molecule biomarkers from nearly-isobaric interferences, and suppresses chemical noise generated in the ion source and in the mass spectrometer, improving selectivity and quantitative accuracy. Our planar DMS design is rapid, operating in a few milliseconds, and analyzes ions before fragmentation. Depending on MS inlet conditions, DMS-selected ions can be dissociated in the MS inlet expansion, before mass analysis, providing a capability similar to MS/MS with simpler instrumentation. This report presents selected DMS-MS experimental results, including resolution of complex test mixtures of isobaric compounds, separation of charge states, separation of isobaric biomarkers (citrate and isocitrate), and separation of nearly-isobaric biomarker anions in direct analysis of a bio-fluid sample from the radiation-treated group of a mouse-model study. These uses of DMS combined with moderate resolution MS instrumentation indicate the feasibility of field-deployable instrumentation for biomarker evaluation.

  9. Stepped MS(All) Relied Transition (SMART): An approach to rapidly determine optimal multiple reaction monitoring mass spectrometry parameters for small molecules.

    Science.gov (United States)

    Ye, Hui; Zhu, Lin; Wang, Lin; Liu, Huiying; Zhang, Jun; Wu, Mengqiu; Wang, Guangji; Hao, Haiping

    2016-02-11

    Multiple reaction monitoring (MRM) is a universal approach for quantitative analysis because of its high specificity and sensitivity. Nevertheless, optimization of MRM parameters remains as a time and labor-intensive task particularly in multiplexed quantitative analysis of small molecules in complex mixtures. In this study, we have developed an approach named Stepped MS(All) Relied Transition (SMART) to predict the optimal MRM parameters of small molecules. SMART requires firstly a rapid and high-throughput analysis of samples using a Stepped MS(All) technique (sMS(All)) on a Q-TOF, which consists of serial MS(All) events acquired from low CE to gradually stepped-up CE values in a cycle. The optimal CE values can then be determined by comparing the extracted ion chromatograms for the ion pairs of interest among serial scans. The SMART-predicted parameters were found to agree well with the parameters optimized on a triple quadrupole from the same vendor using a mixture of standards. The parameters optimized on a triple quadrupole from a different vendor was also employed for comparison, and found to be linearly correlated with the SMART-predicted parameters, suggesting the potential applications of the SMART approach among different instrumental platforms. This approach was further validated by applying to simultaneous quantification of 31 herbal components in the plasma of rats treated with a herbal prescription. Because the sMS(All) acquisition can be accomplished in a single run for multiple components independent of standards, the SMART approach are expected to find its wide application in the multiplexed quantitative analysis of complex mixtures. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Statistical modelling coupled with LC-MS analysis to predict human upper intestinal absorption of phytochemical mixtures.

    Science.gov (United States)

    Selby-Pham, Sophie N B; Howell, Kate S; Dunshea, Frank R; Ludbey, Joel; Lutz, Adrian; Bennett, Louise

    2018-04-15

    A diet rich in phytochemicals confers benefits for health by reducing the risk of chronic diseases via regulation of oxidative stress and inflammation (OSI). For optimal protective bio-efficacy, the time required for phytochemicals and their metabolites to reach maximal plasma concentrations (T max ) should be synchronised with the time of increased OSI. A statistical model has been reported to predict T max of individual phytochemicals based on molecular mass and lipophilicity. We report the application of the model for predicting the absorption profile of an uncharacterised phytochemical mixture, herein referred to as the 'functional fingerprint'. First, chemical profiles of phytochemical extracts were acquired using liquid chromatography mass spectrometry (LC-MS), then the molecular features for respective components were used to predict their plasma absorption maximum, based on molecular mass and lipophilicity. This method of 'functional fingerprinting' of plant extracts represents a novel tool for understanding and optimising the health efficacy of plant extracts. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Comparing depression screening tools in persons with multiple sclerosis (MS).

    Science.gov (United States)

    Hanna, Joshua; Santo, Jonathan B; Blair, Mervin; Smolewska, Kathy; Warriner, Erin; Morrow, Sarah A

    2017-02-01

    Depression is more common among persons with multiple sclerosis (MS) than the general population. Depression in MS is associated with reduced quality of life, transition to unemployment, and cognitive impairment. Two proposed screening measures for depression in MS populations are the Hospital Anxiety and Depression Scale (HADS) and the Beck Depression Inventory-Fast Screen (BDI-FS). Our objective was to compared the associations of the BDI-FS and the HADS-D scores with history of depressive symptoms, fatigue, and functional outcomes to determine the differential clinical utility of these screening measures among persons with MS. We reviewed charts of 133 persons with MS for demographic information; scores on the HADS, BDI-FS, a fatigue measure, and a processing speed measure; and employment status. Structural equation modeling results indicated the HADS-D predicted employment status, disability status, and processing speed more effectively than did the BDI-FS, whereas both measures predicted fatigue. This study suggests the HADS-D is more effective than the BDI-FS in predicting functional outcomes known to be associated with depression among persons with MS. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  12. Derivation from first principles of the statistical distribution of the mass peak intensities of MS data.

    Science.gov (United States)

    Ipsen, Andreas

    2015-02-03

    Despite the widespread use of mass spectrometry (MS) in a broad range of disciplines, the nature of MS data remains very poorly understood, and this places important constraints on the quality of MS data analysis as well as on the effectiveness of MS instrument design. In the following, a procedure for calculating the statistical distribution of the mass peak intensity for MS instruments that use analog-to-digital converters (ADCs) and electron multipliers is presented. It is demonstrated that the physical processes underlying the data-generation process, from the generation of the ions to the signal induced at the detector, and on to the digitization of the resulting voltage pulse, result in data that can be well-approximated by a Gaussian distribution whose mean and variance are determined by physically meaningful instrumental parameters. This allows for a very precise understanding of the signal-to-noise ratio of mass peak intensities and suggests novel ways of improving it. Moreover, it is a prerequisite for being able to address virtually all data analytical problems in downstream analyses in a statistically rigorous manner. The model is validated with experimental data.

  13. Metabolomics data normalization with EigenMS.

    Directory of Open Access Journals (Sweden)

    Yuliya V Karpievitch

    Full Text Available Liquid chromatography mass spectrometry has become one of the analytical platforms of choice for metabolomics studies. However, LC-MS metabolomics data can suffer from the effects of various systematic biases. These include batch effects, day-to-day variations in instrument performance, signal intensity loss due to time-dependent effects of the LC column performance, accumulation of contaminants in the MS ion source and MS sensitivity among others. In this study we aimed to test a singular value decomposition-based method, called EigenMS, for normalization of metabolomics data. We analyzed a clinical human dataset where LC-MS serum metabolomics data and physiological measurements were collected from thirty nine healthy subjects and forty with type 2 diabetes and applied EigenMS to detect and correct for any systematic bias. EigenMS works in several stages. First, EigenMS preserves the treatment group differences in the metabolomics data by estimating treatment effects with an ANOVA model (multiple fixed effects can be estimated. Singular value decomposition of the residuals matrix is then used to determine bias trends in the data. The number of bias trends is then estimated via a permutation test and the effects of the bias trends are eliminated. EigenMS removed bias of unknown complexity from the LC-MS metabolomics data, allowing for increased sensitivity in differential analysis. Moreover, normalized samples better correlated with both other normalized samples and corresponding physiological data, such as blood glucose level, glycated haemoglobin, exercise central augmentation pressure normalized to heart rate of 75, and total cholesterol. We were able to report 2578 discriminatory metabolite peaks in the normalized data (p<0.05 as compared to only 1840 metabolite signals in the raw data. Our results support the use of singular value decomposition-based normalization for metabolomics data.

  14. MS Based Metabonomics

    Energy Technology Data Exchange (ETDEWEB)

    Want, Elizabeth J.; Metz, Thomas O.

    2010-03-01

    Metabonomics is the latest and least mature of the systems biology triad, which also includes genomics and proteomics, and has its origins in the early orthomolecular medicine work pioneered by Linus Pauling and Arthur Robinson. It was defined by Nicholson and colleagues in 1999 as the quantitative measurement of perturbations in the metabolite complement of an integrated biological system in response to internal or external stimuli, and is often used today to describe many non-global types of metabolite analyses. Applications of metabonomics are extensive and include toxicology, nutrition, pharmaceutical research and development, physiological monitoring and disease diagnosis. For example, blood samples from millions of neonates are tested routinely by mass spectrometry (MS) as a diagnostic tool for inborn errors of metabolism. The metabonome encompasses a wide range of structurally diverse metabolites; therefore, no single analytical platform will be sufficient. Specialized sample preparation and detection techniques are required, and advances in NMR and MS technologies have led to enhanced metabonome coverage, which in turn demands improved data analysis approaches. The role of MS in metabonomics is still evolving as instrumentation and software becomes more sophisticated and as researchers realize the strengths and limitations of current technology. MS offers a wide dynamic range, high sensitivity, and reproducible, quantitative analysis. These attributes are essential for addressing the challenges of metabonomics, as the range of metabolite concentrations easily exceeds nine orders of magnitude in biofluids, and the diversity of molecular species ranges from simple amino and organic acids to lipids and complex carbohydrates. Additional challenges arise in generating a comprehensive metabolite profile, downstream data processing and analysis, and structural characterization of important metabolites. A typical workflow of MS-based metabonomics is shown in Figure

  15. sup 9 sup 9 Tc atom counting by quadrupole ICP-MS. Optimisation of the instrumental response

    CERN Document Server

    Mas, J L; Garcia-Leon, M

    2002-01-01

    In this paper, an extensive work is done on the specific tune of a conventional ICP-MS for sup 9 sup 9 Tc atom counting. For this, two methods have been used and compared: the partial variable control method and the 5D Simplex method. Instrumental limits of detection of 0.2 and 0.8 ppt, respectively, were obtained. They are noticeably lower than that found with the automatic tune method of the spectrometer, 47 ppt, which shows the need of a specific tune when very low levels of sup 9 sup 9 Tc have to be determined. A study is presented on the mass interferences for sup 9 sup 9 Tc. Our experiments show that the formation of polyatomic atoms or refractory oxides as well as sup 9 sup 8 Mo hydrides seem to be irrelevant for sup 9 sup 9 Tc atom counting. The opposite occurs with the presence of isobaric interferences, i.e. sup 9 sup 9 Ru, and the effect of abundance sensitivity, or low-mass resolution, which can modify the response at m/z=99 to a non-negligible extent.

  16. Identification of the Predictive Power of Five Factor Personality Traits for Individual Instrument Performance Anxiety

    Science.gov (United States)

    Özdemir, Gökhan; Dalkiran, Esra

    2017-01-01

    This study, with the aim of identifying the predictive power of the five-factor personality traits of music teacher candidates on individual instrument performance anxiety, was designed according to the relational screening model. The study population was students attending the Music Education branch of Fine Arts Education Departments in…

  17. Development and Validation of a UPLC-MS/MS and UPLC-HR-MS Method for the Determination of Fumonisin B1 and Its Hydrolysed Metabolites and Fumonisin B2 in Broiler Chicken Plasma

    Directory of Open Access Journals (Sweden)

    Siegrid De Baere

    2018-01-01

    Full Text Available A sensitive and specific method for the quantitative determination of Fumonisin B1 (FB1, its partially hydrolysed metabolites pHFB1a+b and hydrolysed metabolite HFB1, and Fumonisin B2 (FB2 in broiler chicken plasma using ultra-performance liquid chromatography combined with tandem mass spectrometry (UPLC-MS/MS was developed. The sample preparation was rapid, straightforward and consisted of a deproteinization and phospholipid removal step using an Oasis® OstroTM 96-well plate. Chromatography was performed on an Acquity HSS-T3 column, using 0.3% formic acid and 10 mM ammonium formate in water, and acetonitrile as mobile phases. The MS/MS instrument was operated in the positive electrospray ionization mode and the two multiple reaction monitoring transitions were monitored for each component for quantification and identification, respectively. The method was validated in-house: matrix-matched calibration graphs were prepared and good linearity (r ≥ 0.99 was achieved over the concentration ranges tested (1–500 ng/mL for FB1 and FB2; 0.86–860 ng/mL for pHFB1a; 0.72–1430 ng/mL for pHFB1b and 2.5–2500 ng/mL for HFB1. Limits of quantification (LOQ and detection (LOD in plasma ranged between 0.72 to 2.5 ng/mL and 0.03 to 0.17 ng/mL, respectively. The results for the within-day and between-day precision and accuracy fell within the specified ranges. Moreover, the method was transferred to an UPLC high-resolution mass spectrometry (HR-MS instrument in order to determine potential metabolites of HFB1, such as N-acyl-HFB1s and phase II metabolites. The method has been successfully applied to investigate the toxicokinetics and biotransformation of HFB1 in broiler chickens.

  18. Sensitivity and proportionality assessment of metabolites from microdose to high dose in rats using LC-MS/MS.

    Science.gov (United States)

    Ni, Jinsong; Ouyang, Hui; Seto, Carmai; Sakuma, Takeo; Ellis, Robert; Rowe, Josh; Acheampong, Andrew; Welty, Devin; Szekely-Klepser, Gabriella

    2010-03-01

    The objective of this study was to evaluate the sensitivity requirement for LC-MS/MS as an analytical tool to characterize metabolites in plasma and urine at microdoses in rats and to investigate proportionality of metabolite exposure from a microdose of 1.67 µg/kg to a high dose of 5000 µg/kg for atorvastatin, ofloxacin, omeprazole and tamoxifen. Only the glucuronide metabolite of ofloxacin, the hydroxylation metabolite of omeprazole and the hydration metabolite of tamoxifen were characterized in rat plasma at microdose by LC-MS/MS. The exposure of detected metabolites of omeprazole and tamoxifen appeared to increase in a nonproportional manner with increasing doses. Exposure of ortho- and para-hydroxyatorvastatin, but not atorvastatin and lactone, increased proportionally with increasing doses. LC-MS/MS has demonstrated its usefulness for detecting and characterizing the major metabolites in plasma and urine at microdosing levels in rats. The exposure of metabolites at microdose could not simply be used to predict their exposure at higher doses.

  19. Practical guide to ICP-MS: a tutorial for beginners

    National Research Council Canada - National Science Library

    Thomas, Robert

    2013-01-01

    ... for those with limited knowledge of the technique. Written by an insider with more than 20 years experience in product development, customer support, and technical marketing for an ICP-MS instrument vendor, the book highlights this powerful ultra...

  20. [Prediction instrument for obesity in adolescents at the Policlínico Universitario "Manuel González Díaz", 2013-2014].

    Science.gov (United States)

    Piña Borrego, Carlos Enrique; Fernández Fernández, María de Lourdes; Fonte Rodríguez, Norge; Piña Rodríguez, Lorena Karla

    Obesity is one of the principal non declarable diseases affecting children and adolescents. With the objective of developing a predictive instrument to identify high-risk adolescents with obesity, a cohort prospective study was carried out at the Policlinic "Manuel González Díaz", Bahía Honda City from 2013-2014. It was developed in three stages. In the first stage, 1800 adolescents from 10-19 years of age were included. The prevalence was identified and the most relevant characteristics of obesity were described (defined as body mass index >97 th percentile according to age and sex). In the second stage we identified the possibility of the diagnosis of factors that increase the probability of obesity. The third stage elaborated and validated an obesity predictor instrument from the results of the initial stages. To apply the instrument to sample A for internal elaboration and validation, sensitivity was 77.78% and specificity was 86.11%. Area under the curve (AUC) receiver operating characteristic (ROC) was 0.86, whereas for sample B the sensitivity was 79.63% and specificity was 92.13%. Positive predictive value (PPV) was 83.5% and negative predictive value (NPV) was 90.05%. The instrument allows predicting the risk for developing obesity in adolescents with acceptable sensitivity and high specificity. Its routine application will be interesting in pediatric health consultations. Copyright © 2014 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  1. Optimization of Sample Preparation and Instrumental Parameters for the Rapid Analysis of Drugs of Abuse in Hair samples by MALDI-MS/MS Imaging

    Science.gov (United States)

    Flinders, Bryn; Beasley, Emma; Verlaan, Ricky M.; Cuypers, Eva; Francese, Simona; Bassindale, Tom; Clench, Malcolm R.; Heeren, Ron M. A.

    2017-08-01

    Matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) has been employed to rapidly screen longitudinally sectioned drug user hair samples for cocaine and its metabolites using continuous raster imaging. Optimization of the spatial resolution and raster speed were performed on intact cocaine contaminated hair samples. The optimized settings (100 × 150 μm at 0.24 mm/s) were subsequently used to examine longitudinally sectioned drug user hair samples. The MALDI-MS/MS images showed the distribution of the most abundant cocaine product ion at m/z 182. Using the optimized settings, multiple hair samples obtained from two users were analyzed in approximately 3 h: six times faster than the standard spot-to-spot acquisition method. Quantitation was achieved using longitudinally sectioned control hair samples sprayed with a cocaine dilution series. A multiple reaction monitoring (MRM) experiment was also performed using the `dynamic pixel' imaging method to screen for cocaine and a range of its metabolites, in order to differentiate between contaminated hairs and drug users. Cocaine, benzoylecgonine, and cocaethylene were detectable, in agreement with analyses carried out using the standard LC-MS/MS method. [Figure not available: see fulltext.

  2. Non-aqueous CE-MS of cinchona alkaloids - characterizationof a novel CE-ESI-MS interface

    DEFF Research Database (Denmark)

    Hansen, Frederik André; Hansen, Steen Honoré; Petersen, Nickolaj J.

    We have recently in our group at the University of Copenhagen developed a robust and simple sheatless CE-ESI-MS interface (capillary electrophoresis – electrospray ionization-mass spectrometry). In this presentation the interface is characterized and compared with HPLC-MS for studying...... a submicron fracture in the capillary close the ESI tip. The fracture provides a zero dead volume and excellent conducting properties due to the large amount of ions in the electric double layer. Electric current exceeding the upper limit of CE instrumentation of up to 300 µA can easily be obtained....... Furthermore, the increased conductivity of the buffer in the fracture generates field free pumping of the analytes towards the ESI spray tip. In this study the device was used to analyze the four major alkaloids (diastereomeric pairs of quinine/quinidine and cinchonine/cinchonidine) in Cinchona bark samples...

  3. The Efficacy of Intraoperative Neurophysiological Monitoring Using Transcranial Electrically Stimulated Muscle-evoked Potentials (TcE-MsEPs) for Predicting Postoperative Segmental Upper Extremity Motor Paresis After Cervical Laminoplasty.

    Science.gov (United States)

    Fujiwara, Yasushi; Manabe, Hideki; Izumi, Bunichiro; Tanaka, Hiroyuki; Kawai, Kazumi; Tanaka, Nobuhiro

    2016-05-01

    Prospective study. To investigate the efficacy of transcranial electrically stimulated muscle-evoked potentials (TcE-MsEPs) for predicting postoperative segmental upper extremity palsy following cervical laminoplasty. Postoperative segmental upper extremity palsy, especially in the deltoid and biceps (so-called C5 palsy), is the most common complication following cervical laminoplasty. Some papers have reported that postoperative C5 palsy cannot be predicted by TcE-MsEPs, although others have reported that it can be predicted. This study included 160 consecutive cases that underwent open-door laminoplasty, and TcE-MsEP monitoring was performed in the biceps brachii, triceps brachii, abductor digiti minimi, tibialis anterior, and abductor hallucis. A >50% decrease in the wave amplitude was defined as an alarm point. According to the monitoring alarm, interventions were performed, which include steroid administration, foraminotomies, etc. Postoperative deltoid and biceps palsy occurred in 5 cases. Among the 155 cases without segmental upper extremity palsy, there were no monitoring alarms. Among the 5 deltoid and biceps palsy cases, 3 had significant wave amplitude decreases in the biceps during surgery, and palsy occurred when the patients awoke from anesthesia (acute type). In the other 2 cases in which the palsy occurred 2 days after the operation (delayed type), there were no significant wave decreases. In all of the cases, the palsy was completely resolved within 6 months. The majority of C5 palsies have been reported to occur several days after surgery, but some of them have been reported to occur immediately after surgery. Our results demonstrated that TcE-MsEPs can predict the acute type, whereas the delayed type cannot be predicted. A >50% wave amplitude decrease in the biceps is useful to predict acute-type segmental upper extremity palsy. Further examination about the interventions for monitoring alarm will be essential for preventing palsy.

  4. Potassium Stable Isotopic Compositions Measured by High-Resolution MC-ICP-MS

    Science.gov (United States)

    Morgan, Leah E.; Lloyd, Nicholas S.; Ellam, Robert M.; Simon, Justin I.

    2012-01-01

    Potassium isotopic (K-41/K-39) compositions are notoriously difficult to measure. TIMS measurements are hindered by variable fractionation patterns throughout individual runs and too few isotopes to apply an internal spike method for instrumental mass fractionation corrections. Internal fractionation corrections via the K-40/K-39 ratio can provide precise values but assume identical K-40/K-39 ratios (e.g. 0.05% (1sigma) in [1]); this is appropriate in some cases (e.g. identifying excess K-41) but not others (e.g., determining mass fractionation effects and metrologically traceable isotopic abundances). SIMS analyses have yielded measurements with 0.25% precisions (1sigma) [2]. ICP-MS analyses are significantly affected by interferences from molecular species such as Ar-38H(+) and Ar-40H(+) and instrument mass bias. Single collector ICP-MS instruments in "cold plasma" mode have yielded uncertainties as low as 2% (1sigma, e.g. [3]). Although these precisions may be acceptable for some concentration determinations, they do not resolve isotopic variation in terrestrial materials. Here we present data from a series of measurements made on the Thermo Scientific NEPTUNE Plus multi-collector ICP-MS that demonstrate the ability to make K-41/K-39 ratio measurements with 0.07% precisions (1sigma). These data, collected on NIST K standards, indicate the potential for MC-ICP-MS measurements to look for K isotopic variations at the sub-permil level. The NEPTUNE Plus can sufficiently resolve 39K and 41K from the interfering 38ArH+ and 40ArH+ peaks in wet cold plasma and high-resolution mode. Measurements were made on small but flat, interference-free, plateaus (ca. 50 ppm by mass width for K-41). Although ICP-MS does not yield accurate K-41/K-39 values due to significant instrumental mass fractionation (ca. 6%), this bias can be sufficiently stable over the time required for several measurements so that relative K-41/K-39 values can be precisely determined via sample

  5. Results of the First Mars Organic Molecule Analyzer (MOMA) GC-MS Coupling

    Science.gov (United States)

    Buch, Arnaud; Pinnick, Veronica; Szopa, Cyril; Danell, Ryan; Grand, Noel; Van Amerom, Friso; Glavin, Daniel; Freissinet, Caroline; Humeau, Olivier; Coll, Patrice; Arevalo, Ricardo; Stalport, Fabien; Brinckerhoff, William; Steininger, Harald; Goesmann, Fred; Mahaffy, Paul; Raulin, Francois

    2014-11-01

    The Mars Organic Molecule Analyzer (MOMA) aboard the ExoMars rover will be a key analytical tool in providing chemical (molecular) information from the solid samples collected by the rover, with a particular focus on the char-acterization of the organic content. The core of the MOMA instrument is a gas chromatograph coupled with a mass spectrometer (GC-MS) which provides the unique capability to characterize a broad range of compounds, including both of volatile and non-volatile species. Samples will be crushed and deposited into sample cups seated in a rotating carousel. Soil samples will be analyzed either by UV laser desorption / ionization (LDI) or pyrolysis gas chromatography ion trap mass spectrometry (pyr-GC-ITMS).The French GC brassboard was coupled to the US ion trap mass spectrometer brassboard in a flight-like con-figuration for several coupling campains. The MOMA GC setup is based on the SAM heritage design with a He reservoir and 4 separate analytical modules including traps, columns and Thermal Conductivity Detectors. Solid samples are sealed and heated in this setup using a manual tapping station, designed and built at MPS in Germany, for GC-MS analysis. The gaseous species eluting from the GC are then ionized by an electron impact ionization source in the MS chamber and analyzed by the linear ion trap mass spectrometer. Volatile and non-volatile compounds were injected in the MOMA instrumental suite. Both of these compounds classes were detected by the TCD and by the MS. MS signal (total ion current) and single mass spectra by comparison with the NIST library, gave us an unambiguous confirmation of these identifications. The mass spectra arise from an average of 10 mass spectra averaged around a given time point in the total ion chromatogram.Based on commercial instrument, the MOMA requirement for sensitivity in the GC-MS mode for organic molecules is 1 pmol. In this test, sensitivity was determined for the GC TCD and MS response to a dilution

  6. Determination of 4-Methylimidazole in Ammonia Caramel Using Gas Chromatography–Tandem Mass Spectrometry (GC-MS/MS

    Directory of Open Access Journals (Sweden)

    Martyna N. Wieczorek

    2018-01-01

    Full Text Available One of Maillard reaction products formed in the production of ammonia caramel is 4(5-methylimidazole (4-MeI classified as carcinogen. A method of 4-MeI determination based on ion-pair extraction and derivatisation with isobutyl chloroformate with subsequent gas chromatography-tandem mass spectrometry analysis was proposed. Tandem mass spectrometry was applied to reduce the influence of matrix and increase the selectivity and sensitivity of the method. Triple quadrupole GC-MS system was used for this study. The collision energies were optimized for MRM mode. The detection (LOD and quantification limits (LOQ of the elaborated method were 17 and 37.8 μg kg−1, respectively, repeatability was <15% RSD for analyzed caramel samples, and the recovery for 4-MeI was 101%. Comparison of MS/MS with SIM detection on the same instrument proved almost 30 times lower LODs achieved by tandem mass spectrometry compared to SIM. Described method can be routinely used for monitoring 4-MeI as a quality and safety marker in the production of ammonia caramel.

  7. The coupling of capillary electrophoresis-inductively coupled plasma mass spectrometer as a speciation instrument for actinides at trace level; Le couplage electrophorese capillaire-spectrometre de masse a source plasma en tant qu'instrument de speciation des actinides a l'etat de traces

    Energy Technology Data Exchange (ETDEWEB)

    Delorme, A

    2004-07-01

    An interface between the separation technique (capillary electrophoresis) and the analytical technique (Inductively Coupled Plasma - Mass Spectrometer) was developed. In that sense, bibliographic and parametric studies allowed to define necessary conditions for the good working of both techniques. The results obtained led to the realisation of an interface capillary electrophoresis / ICP-MS (CE / ICP-MS). This one was experimentally validated on classical separations (alkalis / earth-alkalis and lanthanides) and the detection limit of the analytical system was determined equal to 4 x 10{sup -11} mol.L{sup -1} for plutonium. This result exhibits a gain in detection limit of a factor higher than 10{sup 4} compared to the capillary electrophoresis in standard detection (UV). The studies were made in order to check the capacity of the CE / ICP-MS coupling as a speciation instrument for actinides at trace level and to define the associated analytical procedures. The coupling turned out to be a suited instrument for the determination of absolute electrophoretic mobilities at infinite dilution (physico-chemical property which allows to predict the migration time of an ion under an electrical field in a given electrolyte), for the determination of thermodynamic constants and for the separation of different actinide oxidation states in solution. (author)

  8. A comparison of the determination and speciation of inorganic arsenic using general HPLC methodology with UV, MS and MS/MS detection.

    Science.gov (United States)

    Gilmartin, Gregory; Gingrich, Diane

    2018-04-15

    The determination and speciation of arsenic in natural resources such as drinking water and agricultural soils has been a growing concern in recent years due to its many toxicological effects [1-3]. To speciate and quantitate concentrations of arsenic, typically an ion chromatograph (IC) interfaced to an inductively coupled plasma mass spectrometer (ICP-MS) is employed [4-9]. This methodology may be very robust and sensitive, but it is expensive and not as ubiquitous as high performance liquid chromatography (HPLC) with ultraviolet (UV) absorbance detection or electrospray ionization mass spectrometry (ESI-MS). Anion exchange chromatography is a well-documented means of speciating arsenite (As(III), As 2 O 3 ) and arsenate (As(V), AsO 4 ) using UV [10], conductivity [11], or ESI-MS detection [12,13]. This paper demonstrates the utilization of common liquid chromatographic instrumentation to speciate and determines inorganic Arsenic compounds using UV or MS via selected ion recording (SIR) or multiple reaction monitoring (MRM) detection. This paper describes the analysis of arsenite and arsenate samples prepared using both deionized and ground water. The limit of quantitation for the techniques described in this paper for samples spiked in ground water were 454 ppb (As(III)) and 562 ppb (As(V)) for UV detection, 45.4 ppb (As(III)) and 56.2 ppb (As(V)) for SIR detection, and 4.54 ppb (As(III)) and 5.62 ppb (As(V)) for MRM detection. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Method-MS. Final report

    International Nuclear Information System (INIS)

    Skipperud, L.; Popic, J.M.; Roos, P.; Salminen, S.; Nygren, U.; Sigmarsson, O.; Palsson, S.E.

    2011-05-01

    Radiometric determination methods, such as alpha spectrometry require long counting times when low activities are to be determined. Mass spectrometric techniques as Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Thermal Ionisation Mass Spectrometry (TIMS) and Accelerator Mass Spectrometry (AMS) have shown several advantages compared to traditional methods when measuring long-lived radionuclides. Mass spectrometric methods for determination of very low concentrations of elemental isotopes, and thereby isotopic ratios, have been developed using a variety of ion sources. Although primarily applied to the determination of the lighter stable element isotopes and radioactive isotopes in geological studies, the techniques can equally well be applied to the measurement of activity concentrations of long-lived low-level radionuclides in various samples using 'isotope dilution' methods such as those applied in inductively coupled plasma mass spectrometry (ICP-MS). Due to the low specific activity of long-lived radionuclides, many of these are more conveniently detected using mass spectrometric techniques. Mass spectrometry also enables the individual determination of Pu-239 and Pu-240, which cannot be obtained by alpha spectrometry. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) are rapidly growing techniques for the ultra-trace analytical determination of stable and long-lived isotopes and have a wide potential within environmental science, including ecosystem tracers and radio ecological studies. Such instrumentation, of course needs good radiochemical separation, to give best performance. The objectives of the project is to identify current needs and problems within low-level determination of long-lived radioisotopes by ICP-MS, to perform intercalibration and development and improvement of ICP-MS methods for the measurement of radionuclides and isotope ratios and to develop new methods based on modified separation chemistry applied to new auxiliary

  10. Method-MS. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Skipperud, L.; Popic, J.M. (Norwegian Univ. of Life Science (UMB), Isotope Lab. (Norway)); Roos, P. (Technical Univ. of Denmark, Risoe National Lab. for Sustainable Energy, Roskilde (Denmark)); Salminen, S. (Univ. of Helsinki (UH) (Finland)); Nygren, U. (Swedish Defence Research Agency (FOI) (Sweden)); Sigmarsson, O.; Palsson, S.E. (Univ. of Iceland/Icelandic Radiation Protection Institute (Iceland))

    2011-05-15

    Radiometric determination methods, such as alpha spectrometry require long counting times when low activities are to be determined. Mass spectrometric techniques as Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Thermal Ionisation Mass Spectrometry (TIMS) and Accelerator Mass Spectrometry (AMS) have shown several advantages compared to traditional methods when measuring long-lived radionuclides. Mass spectrometric methods for determination of very low concentrations of elemental isotopes, and thereby isotopic ratios, have been developed using a variety of ion sources. Although primarily applied to the determination of the lighter stable element isotopes and radioactive isotopes in geological studies, the techniques can equally well be applied to the measurement of activity concentrations of long-lived low-level radionuclides in various samples using 'isotope dilution' methods such as those applied in inductively coupled plasma mass spectrometry (ICP-MS). Due to the low specific activity of long-lived radionuclides, many of these are more conveniently detected using mass spectrometric techniques. Mass spectrometry also enables the individual determination of Pu-239 and Pu-240, which cannot be obtained by alpha spectrometry. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) are rapidly growing techniques for the ultra-trace analytical determination of stable and long-lived isotopes and have a wide potential within environmental science, including ecosystem tracers and radio ecological studies. Such instrumentation, of course needs good radiochemical separation, to give best performance. The objectives of the project is to identify current needs and problems within low-level determination of long-lived radioisotopes by ICP-MS, to perform intercalibration and development and improvement of ICP-MS methods for the measurement of radionuclides and isotope ratios and to develop new methods based on modified separation chemistry applied to new

  11. Triple Quadrupole Versus High Resolution Quadrupole-Time-of-Flight Mass Spectrometry for Quantitative LC-MS/MS Analysis of 25-Hydroxyvitamin D in Human Serum

    Science.gov (United States)

    Geib, Timon; Sleno, Lekha; Hall, Rabea A.; Stokes, Caroline S.; Volmer, Dietrich A.

    2016-08-01

    We describe a systematic comparison of high and low resolution LC-MS/MS assays for quantification of 25-hydroxyvitamin D3 in human serum. Identical sample preparation, chromatography separations, electrospray ionization sources, precursor ion selection, and ion activation were used; the two assays differed only in the implemented final mass analyzer stage; viz. high resolution quadrupole-quadrupole-time-of-flight (QqTOF) versus low resolution triple quadrupole instruments. The results were assessed against measured concentration levels from a routine clinical chemiluminescence immunoassay. Isobaric interferences prevented the simple use of TOF-MS spectra for extraction of accurate masses and necessitated the application of collision-induced dissociation on the QqTOF platform. The two mass spectrometry assays provided very similar analytical figures of merit, reflecting the lack of relevant isobaric interferences in the MS/MS domain, and were successfully applied to determine the levels of 25-hydroxyvitamin D for patients with chronic liver disease.

  12. Aeroacoustics of Musical Instruments

    NARCIS (Netherlands)

    Fabre, B.; Gilbert, J.; Hirschberg, Abraham; Pelorson, X.

    2012-01-01

    We are interested in the quality of sound produced by musical instruments and their playability. In wind instruments, a hydrodynamic source of sound is coupled to an acoustic resonator. Linear acoustics can predict the pitch of an instrument. This can significantly reduce the trial-and-error process

  13. SprayQc: a real-time LC-MS/MS quality monitoring system to maximize uptime using off the shelf components.

    Science.gov (United States)

    Scheltema, Richard A; Mann, Matthias

    2012-06-01

    With the advent of high-throughput mass spectrometry (MS)-based proteomics, the magnitude and complexity of the performed experiments has increased dramatically. Likewise, investments in chromatographic and MS instrumentation are a large proportion of the budget of proteomics laboratories. Guarding measurement quality and maximizing uptime of the LC-MS/MS systems therefore requires constant care despite automated workflows. We describe a real-time surveillance system, called SprayQc, that continuously monitors the status of the peripheral equipment to ensure that operational parameters are within an acceptable range. SprayQc is composed of multiple plug-in software components that use computer vision to analyze electrospray conditions, monitor the chromatographic device for stable backpressure, interact with a column oven to control pressure by temperature, and ensure that the mass spectrometer is still acquiring data. Action is taken when a failure condition has been detected, such as stopping the column oven and the LC flow, as well as automatically notifying the appropriate operator. Additionally, all defined metrics can be recorded synchronized on retention time with the MS acquisition file, allowing for later inspection and providing valuable information for optimization. SprayQc has been extensively tested in our laboratory, supports third-party plug-in development, and is freely available for download from http://sourceforge.org/projects/sprayqc .

  14. Inductively coupled plasma – Tandem mass spectrometry (ICP-MS/MS): A powerful and universal tool for the interference-free determination of (ultra)trace elements – A tutorial review

    Energy Technology Data Exchange (ETDEWEB)

    Balcaen, Lieve; Bolea-Fernandez, Eduardo [Ghent University, Department of Analytical Chemistry, Krijgslaan 281-S12, B-9000 Ghent (Belgium); Resano, Martín [University of Zaragoza, Department of Analytical Chemistry, Pedro Cerbuna 12, E-50009 Zaragoza (Spain); Vanhaecke, Frank, E-mail: Frank.Vanhaecke@UGent.be [Ghent University, Department of Analytical Chemistry, Krijgslaan 281-S12, B-9000 Ghent (Belgium)

    2015-09-24

    This paper is intended as a tutorial review on the use of inductively coupled plasma – tandem mass spectrometry (ICP-MS/MS) for the interference-free quantitative determination and isotope ratio analysis of metals and metalloids in different sample types. Attention is devoted both to the instrumentation and to some specific tools and procedures available for advanced method development. Next to the more typical reaction gases, e.g., H{sub 2}, O{sub 2} and NH{sub 3}, also the use of promising alternative gases, such as CH{sub 3}F, is covered, and the possible reaction pathways with those reactive gases are discussed. A variety of published applications relying on the use of ICP-MS/MS are described, to illustrate the added value of tandem mass spectrometry in (ultra)trace analysis. - Highlights: • First review on tandem ICP-mass spectrometry (ICP-MS/MS). • Clear description of operating principles of ICP-MS/MS. • Description on how to make use of product ion scans, precursor ion scans and neutral gain scans in method development. • Overview of applications published so far.

  15. Inductively coupled plasma – Tandem mass spectrometry (ICP-MS/MS): A powerful and universal tool for the interference-free determination of (ultra)trace elements – A tutorial review

    International Nuclear Information System (INIS)

    Balcaen, Lieve; Bolea-Fernandez, Eduardo; Resano, Martín; Vanhaecke, Frank

    2015-01-01

    This paper is intended as a tutorial review on the use of inductively coupled plasma – tandem mass spectrometry (ICP-MS/MS) for the interference-free quantitative determination and isotope ratio analysis of metals and metalloids in different sample types. Attention is devoted both to the instrumentation and to some specific tools and procedures available for advanced method development. Next to the more typical reaction gases, e.g., H_2, O_2 and NH_3, also the use of promising alternative gases, such as CH_3F, is covered, and the possible reaction pathways with those reactive gases are discussed. A variety of published applications relying on the use of ICP-MS/MS are described, to illustrate the added value of tandem mass spectrometry in (ultra)trace analysis. - Highlights: • First review on tandem ICP-mass spectrometry (ICP-MS/MS). • Clear description of operating principles of ICP-MS/MS. • Description on how to make use of product ion scans, precursor ion scans and neutral gain scans in method development. • Overview of applications published so far.

  16. Evaluation of multivariate calibration models transferred between spectroscopic instruments

    DEFF Research Database (Denmark)

    Eskildsen, Carl Emil Aae; Hansen, Per W.; Skov, Thomas

    2016-01-01

    In a setting where multiple spectroscopic instruments are used for the same measurements it may be convenient to develop the calibration model on a single instrument and then transfer this model to the other instruments. In the ideal scenario, all instruments provide the same predictions for the ......In a setting where multiple spectroscopic instruments are used for the same measurements it may be convenient to develop the calibration model on a single instrument and then transfer this model to the other instruments. In the ideal scenario, all instruments provide the same predictions...... for the same samples using the transferred model. However, sometimes the success of a model transfer is evaluated by comparing the transferred model predictions with the reference values. This is not optimal, as uncertainties in the reference method will impact the evaluation. This paper proposes a new method...... for calibration model transfer evaluation. The new method is based on comparing predictions from different instruments, rather than comparing predictions and reference values. A total of 75 flour samples were available for the study. All samples were measured on ten near infrared (NIR) instruments from two...

  17. Simultaneous analysis of multiple classes of antimicrobials in environmental water samples using SPE coupled with UHPLC-ESI-MS/MS and isotope dilution.

    Science.gov (United States)

    Tran, Ngoc Han; Chen, Hongjie; Do, Thanh Van; Reinhard, Martin; Ngo, Huu Hao; He, Yiliang; Gin, Karina Yew-Hoong

    2016-10-01

    A robust and sensitive analytical method was developed for the simultaneous analysis of 21 target antimicrobials in different environmental water samples. Both single SPE and tandem SPE cartridge systems were investigated to simultaneously extract multiple classes of antimicrobials. Experimental results showed that good extraction efficiencies (84.5-105.6%) were observed for the vast majority of the target analytes when extraction was performed using the tandem SPE cartridge (SB+HR-X) system under an extraction pH of 3.0. HPLC-MS/MS parameters were optimized for simultaneous analysis of all the target analytes in a single injection. Quantification of target antimicrobials in water samples was accomplished using 15 isotopically labeled internal standards (ILISs), which allowed the efficient compensation of the losses of target analytes during sample preparation and correction of matrix effects during UHPLC-MS/MS as well as instrument fluctuations in MS/MS signal intensity. Method quantification limit (MQL) for most target analytes based on SPE was below 5ng/L for surface waters, 10ng/L for treated wastewater effluents, and 15ng/L for raw wastewater. The method was successfully applied to detect and quantify the occurrence of the target analytes in raw influent, treated effluent and surface water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. [Predictive ocular motor control in Parkinson's disease].

    Science.gov (United States)

    Ying, Li; Liu, Zhen-Guo; Chen, Wei; Gan, Jing; Wang, Wen-An

    2008-02-19

    To investigate the changes of predictive ocular motor function in the patients with Parkinson's disease (PD), and to discuss its clinical value. Videonystagmography (VNG) was used to examine 24 patients with idiopathic Parkinson's disease, 15 males and 9 females, aged 61 +/- 6 (50-69), and 24 sex and age-matched healthy control subjects on random ocular saccade (with the target moving at random intervals to random positions) and predictive ocular saccade (with the 1.25-second light target moving 10 degrees right or left from the center). In the random ocular saccade program, the latency of saccade of the PD patients was 284 ms +/- 58 ms, significantly longer than that of the healthy controls (236 ms +/- 37 ms, P = 0.003). In the predictive ocular saccade pattern, the latency of saccades the PD patients was 150 ms +/- 138 ms, significantly longer than that of the healthy controls (59 ms +/- 102 ms, P = 0.002). The appearance rate of predictive saccades (with the latency of saccade <80 ms) in the PD group was 21%, significantly lower than that in the control group (31%, P = 0.003). There is dysfunction of predictive ocular motor control in the PD patients, and the cognitive function may be impaired at the early stage of PD.

  19. Venocentric lesions: an MRI marker of MS?

    Directory of Open Access Journals (Sweden)

    Matthew P. Quinn

    2013-07-01

    Full Text Available From the earliest descriptions of MS, the venocentric characteristic of plaques was noted. Recently, numerous MRI studies have proposed this finding as a prospective biomarker for MS, which might aid in differentiating MS from other diseases with similar MRI findings. High field MRI studies have shown that penetrating veins can be detected in most MS lesions using T2* weighted or susceptibility weighted imaging. Future studies must address the feasibility of imaging such veins in a clinically practical context. The specificity of this biomarker has been studied only in a limited capacity. Results in microangiopathic lesions are conflicting, whereas asymptomatic white matter hyperintensities as well as lesions of NMO are less frequently venocentric compared to MS plaques. Prospective studies have shown that the presence of venocentric lesions at an early clinical presentation is highly predictive of future MS diagnosis. This is very promising, but work remains to be done to confirm or exclude lesions of common MS mimics, such as ADEM, as venocentric. A number of technical challenges must be addressed before the introduction of this technique as a complementary tool in current diagnostic procedures.

  20. Evaluation of a new preparative supercritical fluid chromatography system for compound library purification: the TharSFC SFC-MS Prep-100 system.

    Science.gov (United States)

    Ebinger, Katalin; Weller, Harold N; Kiplinger, Jeffrey; Lefebvre, Paul

    2011-06-01

    Preparative HPLC-MS is often the method of choice for purification of small amounts (libraries for drug discovery. The method is robust, well proven, and widely applicable. In contrast, preparative supercritical fluid chromatography coupled with mass spectrometry (SFC-MS) has seen only slow acceptance for the same application--despite some potential scientific and economic advantages. One of the reasons for slow adoption of SFC-MS is the lack of well-proven, robust, and commercially available instrumentation. In early 2009, TharSFC (a Waters Company, Pittsburgh, PA) introduced a new fully integrated system for preparative SFC-MS: The SFC-MS Prep-100. We report herein an objective evaluation of the SFC-MS Prep-100, including tests for pump and autosampler performance, sample recovery, sample carryover, fraction triggering, detector/fraction collector synchronization, and overall robustness. Our results suggest that the SFC-MS Prep-100 represents a significant advance over previous generation instrumentation. Copyright © 2011 Society for Laboratory Automation and Screening. Published by Elsevier Inc. All rights reserved.

  1. Recent advances in CE-MS: Synergy of wet chemistry and instrumentation innovations

    Czech Academy of Sciences Publication Activity Database

    Pantůčková, Pavla; Gebauer, Petr; Boček, Petr; Křivánková, Ludmila

    2011-01-01

    Roč. 1, č. 32 (2011), s. 43-51 ISSN 0173-0835 R&D Projects: GA ČR GA203/08/1536; GA ČR GAP206/10/1219; GA AV ČR IAA400310703 Institutional research plan: CEZ:AV0Z40310501 Keywords : CE * Electrolyte systems * MS Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.303, year: 2011

  2. Development of the multiple sclerosis (MS) early mobility impairment questionnaire (EMIQ).

    Science.gov (United States)

    Ziemssen, Tjalf; Phillips, Glenn; Shah, Ruchit; Mathias, Adam; Foley, Catherine; Coon, Cheryl; Sen, Rohini; Lee, Andrew; Agarwal, Sonalee

    2016-10-01

    The Early Mobility Impairment Questionnaire (EMIQ) was developed to facilitate early identification of mobility impairments in multiple sclerosis (MS) patients. We describe the initial development of the EMIQ with a focus on the psychometric evaluation of the questionnaire using classical and item response theory methods. The initial 20-item EMIQ was constructed by clinical specialists and qualitatively tested among people with MS and physicians via cognitive interviews. Data from an observational study was used to make additional updates to the instrument based on exploratory factor analysis (EFA) and item response theory (IRT) analysis, and psychometric analyses were performed to evaluate the reliability and validity of the final instrument's scores and screening properties (i.e., sensitivity and specificity). Based on qualitative interview analyses, a revised 15-item EMIQ was included in the observational study. EFA, IRT and item-to-item correlation analyses revealed redundant items which were removed leading to the final nine-item EMIQ. The nine-item EMIQ performed well with respect to: test-retest reliability (ICC = 0.858); internal consistency (α = 0.893); convergent validity; and known-groups methods for construct validity. A cut-point of 41 on the 0-to-100 scale resulted in sufficient sensitivity and specificity statistics for viably identifying patients with mobility impairment. The EMIQ is a content valid and psychometrically sound instrument for capturing MS patients' experience with mobility impairments in a clinical practice setting. Additional research is suggested to further confirm the EMIQ's screening properties over time.

  3. Predicting Falls in Parkinson Disease: What Is the Value of Instrumented Testing in OFF Medication State?

    Directory of Open Access Journals (Sweden)

    Martina Hoskovcová

    Full Text Available Falls are a common complication of advancing Parkinson's disease (PD. Although numerous risk factors are known, reliable predictors of future falls are still lacking. The objective of this prospective study was to investigate clinical and instrumented tests of balance and gait in both OFF and ON medication states and to verify their utility in the prediction of future falls in PD patients.Forty-five patients with idiopathic PD were examined in defined OFF and ON medication states within one examination day including PD-specific clinical tests, instrumented Timed Up and Go test (iTUG and computerized dynamic posturography. The same gait and balance tests were performed in 22 control subjects of comparable age and sex. Participants were then followed-up for 6 months using monthly fall diaries and phone calls.During the follow-up period, 27/45 PD patients and 4/22 control subjects fell one or more times. Previous falls, fear of falling, more severe motor impairment in the OFF state, higher PD stage, more pronounced depressive symptoms, higher daily levodopa dose and stride time variability in the OFF state were significant risk factors for future falls in PD patients. Increased stride time variability in the OFF state in combination with faster walking cadence appears to be the most significant predictor of future falls, superior to clinical predictors.Incorporating instrumented gait measures into the baseline assessment battery as well as accounting for both OFF and ON medication states might improve future fall prediction in PD patients. However, instrumented testing in the OFF state is not routinely performed in clinical practice and has not been used in the development of fall prevention programs in PD. New assessment methods for daylong monitoring of gait, balance and falls are thus required to more effectively address the risk of falling in PD patients.

  4. Predicting Metabolic Syndrome Using the Random Forest Method

    Directory of Open Access Journals (Sweden)

    Apilak Worachartcheewan

    2015-01-01

    Full Text Available Aims. This study proposes a computational method for determining the prevalence of metabolic syndrome (MS and to predict its occurrence using the National Cholesterol Education Program Adult Treatment Panel III (NCEP ATP III criteria. The Random Forest (RF method is also applied to identify significant health parameters. Materials and Methods. We used data from 5,646 adults aged between 18–78 years residing in Bangkok who had received an annual health check-up in 2008. MS was identified using the NCEP ATP III criteria. The RF method was applied to predict the occurrence of MS and to identify important health parameters surrounding this disorder. Results. The overall prevalence of MS was 23.70% (34.32% for males and 17.74% for females. RF accuracy for predicting MS in an adult Thai population was 98.11%. Further, based on RF, triglyceride levels were the most important health parameter associated with MS. Conclusion. RF was shown to predict MS in an adult Thai population with an accuracy >98% and triglyceride levels were identified as the most informative variable associated with MS. Therefore, using RF to predict MS may be potentially beneficial in identifying MS status for preventing the development of diabetes mellitus and cardiovascular diseases.

  5. Recent advances in the instrumental techniques for the analysis of modern materials (II)

    International Nuclear Information System (INIS)

    Ahmed, M.

    1990-01-01

    Inductively Coupled Plasma Mass Spectrometry ICP-MS a logical development of equally established sister technique of ICP-AEA discussed in part-1 of this series of article on modern analytical techniques. The rapid adaptation of argon plasma as ion source for time of flight quadrupole mass analyser has led to the development of truly integrated instrumental technique for analysis of solutions and slurries. The powerful combination with laser ablation device has made the direct analysis of geological, geochemical and other complex conducting and non conducting samples possible in days rather months at sub ppm levels. Parallel development in computer hardware and software has made the instrumental optimization easy enabling the generation of meaningful analytical data a matter of routine. The limitations imposed by spectroscopic and non restricted the variety of matrices and materials covered by ICP-MS of LA-ICP-MS. The technique has provided it formidable analytical power in wide areas of industrial environmental, social, biological and break through advanced materials used in space mass communication, transportation and general areas of advanced analytical chemistry. It is expected that in combination with other instrumental methods as HPLC, ETC, ion chromatography. ICP-MS shall continue to dominate well into the 21st century. (author)

  6. MS-Based Analytical Techniques: Advances in Spray-Based Methods and EI-LC-MS Applications

    Science.gov (United States)

    Medina, Isabel; Cappiello, Achille; Careri, Maria

    2018-01-01

    Mass spectrometry is the most powerful technique for the detection and identification of organic compounds. It can provide molecular weight information and a wealth of structural details that give a unique fingerprint for each analyte. Due to these characteristics, mass spectrometry-based analytical methods are showing an increasing interest in the scientific community, especially in food safety, environmental, and forensic investigation areas where the simultaneous detection of targeted and nontargeted compounds represents a key factor. In addition, safety risks can be identified at the early stage through online and real-time analytical methodologies. In this context, several efforts have been made to achieve analytical instrumentation able to perform real-time analysis in the native environment of samples and to generate highly informative spectra. This review article provides a survey of some instrumental innovations and their applications with particular attention to spray-based MS methods and food analysis issues. The survey will attempt to cover the state of the art from 2012 up to 2017.

  7. Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations

    Directory of Open Access Journals (Sweden)

    Ghassan Yared

    2015-02-01

    Full Text Available This report introduces a novel technique that allows a safe and predictable canal negotiation, creation of a glide path and canal preparation with reciprocating nickel-titanium or stainless steel engine-driven instruments in canals where the use of rotary and the newly developed reciprocating instruments is contraindicated. In this novel technique, the instruments are used in reciprocating motion with very small angles. Hand files are not used regardless of the complexity of the canal anatomy. It also allows achieving predictable results in canal negotiation and glide path creation in challenging canals without the risk of instrument fracture.

  8. Analysis of phytochemical variations in dioecious Tinospora cordifolia stems using HPLC/QTOF MS/MS and UPLC/QqQLIT -MS/MS.

    Science.gov (United States)

    Bajpai, Vikas; Singh, Awantika; Chandra, Preeti; Negi, M P S; Kumar, Nikhil; Kumar, Brijesh

    2016-01-01

    The stem of dioecious Tinospora cordifolia (Menispermaceae) is a commonly used traditional Ayurvedic medicine in India having several therapeutic properties. To develop and validate LC-MS methods for the identification and simultaneous quantitation of various secondary metabolites and to study metabolomic variations in the stem of male and female plants. Ethanolic extract of stems were analysed by HPLC/ESI-QTOF-MS/MS for rapid screening of bioactive phytochemicals. High resolution MS and MS/MS in positive ESI mode were used for structural investigation of secondary metabolites. An UPLC/ESI-QqQ(LIT) -MS/MS method in MRM mode was developed and validated for the simultaneous quantitation of five bioactive alkaloids. Identification and characterisation of 36 metabolites including alkaloids, sesquiterpenes and phytoecdysteroids were performed using LC-MS and MS/MS techniques. The bioactive alkaloids such as jatrorrhizine, magnoflorine, isocorydine, palmatine and tetrahydropalmatine were successfully quantified in male and female plants. The mean abundances of magnoflorine jatrorrhizine, and oblongine were significantly (P Phytochemicals in the stem of male and female Tinospora cordifolia showed significant qualitative and quantitative variations. LC-MS and MS/MS methods can be used to differentiate between male and female plants based on their chemical profiles and quantities of the marker bioactive alkaloids. This chemical composition difference was also evident during vegetative stage when there were no male and female flowers. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Determination of Glyphosate Levels in Breast Milk Samples from Germany by LC-MS/MS and GC-MS/MS

    NARCIS (Netherlands)

    Steinborn, Angelika; Alder, Lutz; Michalski, Britta; Zomer, Paul; Bendig, Paul; Martinez, Sandra Aleson; Mol, Hans G.J.; Class, Thomas J.; Costa Pinheiro, Nathalie

    2016-01-01

    This study describes the validation and application of two independent analytical methods for the determination of glyphosate in breast milk. They are based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS), respectively. For

  10. Identification and quantification of cardiac glycosides in blood and urine samples by HPLC/MS/MS.

    Science.gov (United States)

    Guan, F; Ishii, A; Seno, H; Watanabe-Suzuki, K; Kumazawa, T; Suzuki, O

    1999-09-15

    Cardiac glycosides (CG) are of forensic importance because of their toxicity and the fact that very limited methods are available for identification of CG in biological samples. In this study, we have developed an identification and quantification method for digoxin, digitoxin, deslanoside, digoxigenin, and digitoxigenin by high-performance liquid chromatography tandem mass spectrometry (HPLC/MS/MS). CG formed abundant [M + NH4]+ ions and much less abundant [M + H]+ ions as observed with electrospray ionization (ESI) source and ammonium formate buffer. Under mild conditions for collision-induced dissociation (CID), each [M + NH4]+ ion fragmented to produce a dominant daughter ion, which was essential to the sensitive method of selected reaction monitoring (SRM) quantification of CG achieved in this study. SRM was compared with selected ion monitoring (SIM) regarding the effects of sample matrixes on the methodology. SRM produced lower detection limits with biological samples than SIM, while both methods produced equal detection limits with CG standards. On the basis of the HPLC/MS/MS results for CG, we have proposed some generalized points for conducting sensitive SRM measurements, in view of the property of analytes as well as instrumental conditions such as the type of HPLC/MS interface and CID parameters. Analytes of which the molecular ion can produce one abundant daughter ion with high yield under CID conditions may be sensitively measured by SRM. ESI is the most soft ionization source developed so far and can afford formation of the fragile molecular ions that are necessary for sensitive SRM detection. Mild CID conditions such as low collision energy and low pressure of collision gas favor production of an abundant daughter ion that is essential to sensitive SRM detection. This knowledge may provide some guidelines for conducting sensitive SRM measurements of very low concentrations of drugs or toxicants in biological samples.

  11. Multisteroid LC–MS/MS assay for glucocorticoids and androgens and its application in Addison's disease

    Science.gov (United States)

    Methlie, Paal; Hustad, Steinar; Kellman, Ralf; Almås, Bjørg; Erichsen, Martina M; Husebye, Eystein S; Løvås, Kristian

    2013-01-01

    Objective Liquid chromatography–tandem mass spectrometry (LC–MS/MS) offers superior analytical specificity compared with immunoassays, but it is not available in many regions and hospitals due to expensive instrumentation and tedious sample preparation. Thus, we developed an automated, high-throughput LC–MS/MS assay for simultaneous quantification of ten endogenous and synthetic steroids targeting diseases of the hypothalamic–pituitary–adrenal axis and gonads. Methods Deuterated internal standards were added to 85 μl serum and processed by liquid–liquid extraction. Cortisol, cortisone, prednisolone, prednisone, 11-deoxycortisol, dexamethasone, testosterone, androstenedione and progesterone were resolved by ultra-high-pressure chromatography on a reversed-phase column in 6.1 min and detected by triple-quadrupole mass spectrometry. The method was used to assess steroid profiles in women with Addison's disease (AD, n=156) and blood donors (BDs, n=102). Results Precisions ranged from 4.5 to 10.1% relative standard deviations (RSD), accuracies from 95 to 108% and extraction recoveries from 60 to 84%. The method was practically free of matrix effects and robust to individual differences in serum composition. Most postmenopausal AD women had extremely low androstenedione concentrations, below 0.14 nmol/l, and median testosterone concentrations of 0.15 nmol/l (interquartile range 0.00–0.41), considerably lower than those of postmenopausal BDs (1.28 nmol/l (0.96–1.64) and 0.65 nmol/l (0.56–1.10) respectively). AD women in fertile years had androstenedione concentrations of 1.18 nmol/l (0.71–1.76) and testosterone concentrations of 0.44 nmol/l (0.22–0.63), approximately half of those found in BDs of corresponding age. Conclusion This LC–MS/MS assay provides highly sensitive and specific assessments of glucocorticoids and androgens with low sample volumes and is suitable for endocrine laboratories and research. Its utility has been

  12. Comparative study for toxic elements determination in air particulate reference material by INAA, CCT-ICP-MS, and ICP-MS

    International Nuclear Information System (INIS)

    Lim, J.M.; Lee, J.H.; Kim, K.H.; Moon, J.H.; Chung, Y.S.

    2005-01-01

    Although toxic elements are minor components in the atmospheric environment, they play a significant role as important marker for atmospheric science such as risk assessment, long-range transfer study, and source apportionment. Therefore, the techniques, which allow accurate and fast elemental analysis with a minimum pre-treatment, are very important. INAA has a main advantage of non-destruction of air particulate samples, while inductively Coupled plasma with mass spectrometry (ICP-MS) encounters the most significant difficulties in pre-treatment (digestion, fusion, and dilution) and polyatomic spectral interferences for interest toxic elements, Although INAA is still reference method, a number of factors (disadvantages of cost, complexity of the instruments, and scarcity of nuclear reactor) limit its applications. To date, the use of collision cell technology ICP-MS (CCT-ICP-MS) is recommended instead of typical ICP-MS for the analysis of the toxic elements; this is because CCT-ICP-MS technique prevents polyatomic spectral interferences despite of contamination and volatile effects. In this study, a number of toxic elements in reference material, NIST SRM 2783 (air particulate on filter media) were determined by INAA, CCT-ICP-MS, and ICP-MS. For both ICP methods, the filters were decomposed by microwave digestion with 5mL nitric acid. The analytical results by three methods were compared with certificated data; the INAA results showed the most accurate and precise data sets for all target elements among three methods. In detail, the deviation between analytical results and SRM's by INAA fell below 10% for all elements excluding As (14%), while those by CCT-ICP-MS were about 20%. For ICP-MS, the result does not agree with certificated data for several elements, because polyatomic spectral interference (due to 40 Ar 35 Cl, 40 Ar 23 Na, and 35 Cl 16 O) generate positive error of analytical result for As, Cu, and V. Based on our result, INAA is still one of the most

  13. Strategy for Hepatotoxicity Prediction Induced by Drug Reactive Metabolites Using Human Liver Microsome and Online 2D-Nano-LC-MS Analysis.

    Science.gov (United States)

    Zhuo, Yue; Wu, Jian-Lin; Yan, Xiaojing; Guo, Ming-Quan; Liu, Ning; Zhou, Hua; Liu, Liang; Li, Na

    2017-12-19

    Hepatotoxicity is a leading cause of drug withdrawal from the market; thus, the assessment of potential drug induced liver injury (DILI) in preclinical trials is necessary. More and more research has shown that the covalent modification of drug reactive metabolites (RMs) for cellular proteins is a possible reason for DILI. Unfortunately, so far no appropriate method can be employed to evaluate this kind of DILI due to the low abundance of RM-protein adducts in complex biological samples. In this study, we proposed a mechanism-based strategy to solve this problem using human liver microsomes (HLMs) and online 2D nano-LC-MS analysis. First, RM modification patterns and potential modified AA residues are determined using HLM and model amino acids (AAs) by UHPLC-Q-TOF-MS. Then, a new online 2D-nano-LC-Q-TOF-MS method is established and applied to separate the digested modified microsomal peptides from high abundance peptides followed by identification of RM-modified proteins using Mascot, in which RM modification patterns on specific AA residues are added. Finally, the functions and relationship with hepatotoxicity of the RM-modified proteins are investigated using ingenuity pathway analysis (IPA) to predict the possible DILI. Using this strategy, 21 proteins were found to be modified by RMs of toosendanin, a hepatotoxic drug with complex structure, and some of them have been reported to be associated with hepatotoxicity. This strategy emphasizes the identification of drug RM-modified proteins in complex biological samples, and no pretreatment is required for the drugs. Consequently, it may serve as a valuable method to predict potential DILI, especially for complex compounds.

  14. Predicting inpatient violence using an extended version of the Brøset-Violence-Checklist: instrument development and clinical application

    Directory of Open Access Journals (Sweden)

    Haug Hans-Joachim

    2006-04-01

    Full Text Available Abstract Background Patient aggression is a common problem in acute psychiatric wards and calls for preventive measures. The timely use of preventive measures presupposes a preceded risk assessment. The Norwegian Brøset-Violence-Checklist (BVC is one of the few instruments suited for short-time prediction of violence of psychiatric inpatients in routine care. Aims of our study were to improve the accuracy of the short-term prediction of violence in acute inpatient settings by combining the Brøset-Violence-Checklist (BVC with an overall subjective clinical risk-assessment and to test the application of the combined measure in daily practice. Method We conducted a prospective cohort study with two samples of newly admitted psychiatric patients for instrument development (219 patients and clinical application (300 patients. Risk of physical attacks was assessed by combining the 6-item BVC and a 6-point score derived from a Visual Analog Scale. Incidents were registered with the Staff Observation of Aggression Scale-Revised SOAS-R. Test accuracy was described as the area under the receiver operating characteristic curve (AUCROC. Results The AUCROC of the new VAS-complemented BVC-version (BVC-VAS was 0.95 in and 0.89 in the derivation and validation study respectively. Conclusion The BVC-VAS is an easy to use and accurate instrument for systematic short-term prediction of violent attacks in acute psychiatric wards. The inclusion of the VAS-derived data did not change the accuracy of the original BVC.

  15. Finding of pesticides in fashionable fruit juices by LC-MS/MS and GC-MS/MS.

    Science.gov (United States)

    Tran, Kevin; Eide, David; Nickols, Susan M; Cromer, Michele R; Sabaa-Srur, Armando; Smith, Robert E

    2012-10-15

    Products labelled as containing extracts from two mushrooms (cordyceps plus reishi) and the juices from açaí, goji, mangosteen, noni, pomegranate, and sea buckthorn have been analysed for 174 different pesticides, using the validated QuEChERS method for sample preparation and electrospray LC-MS/MS in the positive ion mode for analysis. Pesticides were found in 10 of the 21 samples analysed. Most pesticides found were below the tolerance levels (1-6 μg/g, depending on the pesticide), but some were not. This included boscalid, dimethomorph, iprovalicarb, pyridaben, pyrimethanil, and imazalil, for which there is no tolerance reported or zero tolerance in any fruit. However, genuine açaí that was harvested in the state of Pará and lyophilised in Rio de Janeiro had no detectable pesticides, when analysed by both LC-MS/MS and GC-MS/MS, which can detect 213 more pesticides and industrial chemicals. Likewise no pesticides were found in one sample each of cordyceps plus reishi, sea buckthorn and noni. Published by Elsevier Ltd.

  16. MacMS: A Mass Spectrometer Simulator: Abstract of Issue 9906M

    Science.gov (United States)

    Bigger, Stephen W.; Craig, Robert A.

    1999-10-01

    MacMS is a program for Mac-OS compatible computers that simulates a magnetic sector mass spectrometer (1-4) designed to operate in the mass-to-charge (m/z) ratio range of 1-200 amu. MacMS has two operational modules. The first module (see Figure 1) is called the "Path" module and enables the user to quantitatively examine the trajectory of an ion of given m/z ratio in the electric and magnetic fields of the simulated "instrument". By systematically measuring a series of trajectories of different ions under different electric and magnetic field conditions, the user can determine how the resolution of the "instrument" is affected by these experimentally variable parameters. The user can thus choose suitable instrumental conditions for scanning a given m/z ratio range with good separation between the peaks. The second module (see Figure 2) is called as the "Spectrometer" module and enables the user to record, under any chosen instrumental conditions, the mass spectrum of (i) the instrumental background, (ii) neon, (iii) methane, or (iv) the parent ion of carbon tetrachloride. Both voltage scanning and magnetic scanning are possible (5). A hard copy of any mass spectrum that has been recorded can also be obtained. MacMS can read ASCII data files containing mass spectral information of compounds other than those that are "built-in" to the simulator. The appropriate format for creating such data files is described in the program documentation. There are a number of instructional exercises that can be conducted using the mass spectral information contained within the simulator. These are included in the program documentation. For example, the intensities of the 20Ne+, 21Ne+, and 22Ne+ species can be determined from hard copies of mass spectra of neon that are obtained under different instrumental sensitivities. The relative abundances of the three isotopes of neon can thus be calculated and compared with the literature values (6). The simulator also includes adjustable

  17. Using instrumental (CIE and reflectance) measures to predict consumers' acceptance of beef colour.

    Science.gov (United States)

    Holman, Benjamin W B; van de Ven, Remy J; Mao, Yanwei; Coombs, Cassius E O; Hopkins, David L

    2017-05-01

    We aimed to establish colorimetric thresholds based upon the capacity for instrumental measures to predict consumer satisfaction with beef colour. A web-based survey was used to distribute standardised photographs of beef M. longissimus lumborum with known colorimetrics (L*, a*, b*, hue, chroma, ratio of reflectance at 630nm and 580nm, and estimated deoxymyoglobin, oxymyoglobin and metmyoglobin concentrations) for scrutiny. Consumer demographics and perceived importance of colour to beef value were also evaluated. It was found that a* provided the most simple and robust prediction of beef colour acceptability. Beef colour was considered acceptable (with 95% acceptance) when a* values were equal to or above 14.5. Demographic effects on this threshold were negligible, but consumer nationality and gender did contribute to variation in the relative importance of colour to beef value. These results provide future beef colour studies with context to interpret objective colour measures in terms of consumer acceptance and market appeal. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  18. Commissioning of the AEI MS702 mass spectrometer

    International Nuclear Information System (INIS)

    Pearton, D.C.G.; Sobiecki, A.

    1978-01-01

    The setting-up and commissioning of the AEI MS702 mass spectrometer is described. Its individual components and their use are discussed, as well as the sample preparation, analysis, and reduction of data. A comprehensive list is given of instrumental breakdowns, and the application of the technique to several matrices is outlined. Improvements and modifications to the technique, including the use of a minicomputer, are suggested

  19. Pediatric MS

    Science.gov (United States)

    ... Pediatric MS Share this page Facebook Twitter Email Pediatric MS Pediatric MS Pediatric MS Support Pediatric Providers ... system through the Pediatric MS Support Group . Treating pediatric MS In 2018 the U.S. Food and Drug ...

  20. Hilbert-Huang transform based instrumental assessment of intention tremor in multiple sclerosis

    Science.gov (United States)

    Carpinella, Ilaria; Cattaneo, Davide; Ferrarin, Maurizio

    2015-08-01

    Objective. This paper describes a method to extract upper limb intention tremor from gyroscope data, through the Hilbert-Huang transform (HHT), a technique suitable for the study of nonlinear and non-stationary processes. The aims of the study were to: (i) evaluate the method’s ability to discriminate between healthy controls and MS subjects; (ii) validate the proposed procedure against clinical tremor scores assigned using Fahn’s tremor rating scale (FTRS); and (iii) compare the performance of the HHT-based method with that of linear band-pass filters. Approach. HHT was applied on gyroscope data collected on 20 MS subjects and 13 healthy controls (CO) during finger-to-nose tests (FNTs) instrumented with an inertial sensor placed on the hand. The results were compared to those obtained after traditional linear filtering. The tremor amplitude was quantified with instrumental indexes (TIs) and clinical FTRS ratings. Main results. The TIs computed after HHT-based filtering discriminated between CO and MS subjects with clinically-detected intention tremor (MS_T). In particular, TIs were significantly higher in the final part of the movement (TI2) with respect to the first part (TI1), and, for all components (X, Y, Z), MST showed a TI2 significantly higher than in CO subjects. Moreover, the HHT detected subtle alterations not visible from clinical ratings, as TI2 (Z-component) was significantly increased in MS subjects without clinically-detected tremor (MS_NT). The method’s validity was demonstrated by significant correlations between clinical FTRS scores and TI2 related to X (rs = 0.587, p = 0.006) and Y (rs = 0.682, p < 0.001) components. Contrarily, fewer differences among the groups and no correlation between instrumental and clinical indexes emerged after traditional filtering. Significance. The present results supported the use of the HHT-based procedure for a fully-automated quantitative and objective measure of intention tremor in MS, which can overcome

  1. Quantification and speciation of technetium-99 in samples at low levels: contributions of capillary electrophoresis / ICP-MS system

    International Nuclear Information System (INIS)

    Kasprzak, L.M.

    2007-01-01

    Given the low levels of 99 Tc (long half-lived artificial radionuclide) in the environment (10 -8 M to 10 -12 M), its determination currently necessitates an enrichment and separation from the sample matrix prior to instrumental measurement. Therefore, nuclear safety monitoring requires the knowledge of the redox and chemical properties of this element in order to predict its behaviour and transfer in the environment. So, a separative and very sensitive measurement technique must thus be employed. We have developed a new environmental measurement method applied to the quantification and speciation of 99 Tc in sample at environmental concentrations. Indeed, we have combined a Capillary Electrophoresis (CE) with an Inductively Coupled Plasma Mass Spectrometer (ICP-MS). The limit of detection of 99 Tc is about 2.10 -8 M by CE/ICP-MS system equipped with a PFA-50 nebuliser. In addition to the detection and measurement of technetium, we can separate online 99 Tc(VII) of its interfering radionuclides like molybdenum and ruthenium by CE/ICP-MS. Indeed, due do the different migration time of each anions, it's possible to determinate a signal at m/z= 99 which is only given to 99 Tc. Results obtained by this method have been compared to an usual radiochemical technique, extraction of Tc(VII) by a TEVA resin followed by ICP-MS measurement. Within the framework of storage of spent fuel, studies on the speciation of Tc(VII) by CE / ICP-MS iron-sulphide soils in anoxic conditions have shown that technetium VII is reduced by sulphured suspensions. (author)

  2. ChiMS: Open-source instrument control software platform on LabVIEW for imaging/depth profiling mass spectrometers.

    Science.gov (United States)

    Cui, Yang; Hanley, Luke

    2015-06-01

    ChiMS is an open-source data acquisition and control software program written within LabVIEW for high speed imaging and depth profiling mass spectrometers. ChiMS can also transfer large datasets from a digitizer to computer memory at high repetition rate, save data to hard disk at high throughput, and perform high speed data processing. The data acquisition mode generally simulates a digital oscilloscope, but with peripheral devices integrated for control as well as advanced data sorting and processing capabilities. Customized user-designed experiments can be easily written based on several included templates. ChiMS is additionally well suited to non-laser based mass spectrometers imaging and various other experiments in laser physics, physical chemistry, and surface science.

  3. Report on the survey of geothermal development at Okushiri Island, Hokkaido. Geochemical survey (GC/MS and MS method); Hokkaido Okushiritou chinetsu kaihatsu chosa chikagaku chosa (GC/MS and MS ho) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-09-01

    To elucidate chemical components of soil gas in the Okushiri Island area, soil gas was collected by the method using charcoal adsorbent, and analysis was made by the GC/MS method. Out of the 19 measuring points, 17 points were set up near the measuring points in the FY 1998 survey by the finger print method. At the same measuring points, analytical survey by the MS method was also conducted to sort the type of soil gas. As a result of the GC/MS analysis, xylene or ethyl benzene was detected at 12 measuring points of all 19 measuring points, and from the distribution, it was predicted that there were anomaly zones in the district along the road of the Okushiri Island line and the district southward from the 5.8K Pass. These results were in harmony with the results of the survey by the finger print method. As to the sorting of soil gas based on the results of the MS analysis, the results were different at 8 measuring points from those of the survey by the finger print method in FY 1998. It was considered that the cause was the accidental vaporization of a large quantity of acetaldehyde, and acetaldehyde was regarded as a noise gas component that does not reflect the geothermal structure. (NEDO)

  4. Software Tools and Approaches for Compound Identification of LC-MS/MS Data in Metabolomics

    Directory of Open Access Journals (Sweden)

    Ivana Blaženović

    2018-05-01

    Full Text Available The annotation of small molecules remains a major challenge in untargeted mass spectrometry-based metabolomics. We here critically discuss structured elucidation approaches and software that are designed to help during the annotation of unknown compounds. Only by elucidating unknown metabolites first is it possible to biologically interpret complex systems, to map compounds to pathways and to create reliable predictive metabolic models for translational and clinical research. These strategies include the construction and quality of tandem mass spectral databases such as the coalition of MassBank repositories and investigations of MS/MS matching confidence. We present in silico fragmentation tools such as MS-FINDER, CFM-ID, MetFrag, ChemDistiller and CSI:FingerID that can annotate compounds from existing structure databases and that have been used in the CASMI (critical assessment of small molecule identification contests. Furthermore, the use of retention time models from liquid chromatography and the utility of collision cross-section modelling from ion mobility experiments are covered. Workflows and published examples of successfully annotated unknown compounds are included.

  5. Experimental design for optimizing MALDI-TOF-MS analysis of palladium complexes

    Directory of Open Access Journals (Sweden)

    Rakić-Kostić Tijana M.

    2017-01-01

    Full Text Available This paper presents optimization of matrix-assisted laser desorption/ionization (MALDI time-of-flight (TOF mass spectrometer (MS instrumental parameters for the analysis of chloro(2,2'',2"-terpyridinepalladium(II chloride dihydrate complex applying design of experiments methodology (DoE. This complex is of interest for potential use in the cancer therapy. DoE methodology was proved to succeed in optimization of many complex analytical problems. However, it has been poorly used for MALDI-TOF-MS optimization up to now. The theoretical mathematical relationships which explain the influence of important experimental factors (laser energy, grid voltage and number of laser shots on the selected responses (signal to noise – S/N ratio and the resolution – R of the leading peak is established. The optimal instrumental settings providing maximal S/N and R are identified and experimentally verified. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 172052 and Grant no. 172011

  6. The Role of Clinical and Instrumented Outcome Measures in Balance Control of Individuals with Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Neeta Kanekar

    2013-01-01

    Full Text Available Purpose. The aim of the study was to investigate differences in balance control between individuals with multiple sclerosis (MS and healthy control subjects using clinical scales and instrumented measures of balance and determine relationships between balance measures, fatigue, and disability levels in individuals with MS with and without a history of falls. Method. Twelve individuals with MS and twelve healthy controls were evaluated using the Berg Balance and Activities-specific Balance Confidence Scales, Modified Clinical Test of Sensory Interaction on Balance, and Limits of Stability Tests as well as Fatigue Severity Scale and Barthel Index. Results. Mildly affected individuals with MS had significant balance performance deficits and poor balance confidence levels (P<0.05. MS group had higher sway velocities and diminished stability limits (P<0.05, significant sensory impairments, high fatigue and disability levels (P<0.05. Sway velocity was a significant predictor of balance performance and the ability to move towards stability limits for the MS group. For the MS-fallers group, those with lower disability levels had faster movement velocities and better balance performance. Conclusion. Implementation of both clinical and instrumented tests of balance is important for the planning and evaluation of treatment outcomes in balance rehabilitation of people with MS.

  7. Predicting inpatient violence using an extended version of the Brøset-Violence-Checklist: instrument development and clinical application

    OpenAIRE

    Abderhalden, Christoph; Needham, Ian; Dassen, Theo; Halfens, Ruud; Haug, Hans-Joachim; Fischer, Joachim

    2006-01-01

    Abstract Background Patient aggression is a common problem in acute psychiatric wards and calls for preventive measures. The timely use of preventive measures presupposes a preceded risk assessment. The Norwegian Brøset-Violence-Checklist (BVC) is one of the few instruments suited for short-time prediction of violence of psychiatric inpatients in routine care. Aims of our study were to improve the accuracy of the short-term prediction of violence in acute inpatient settings by combining the B...

  8. Plutonium bioassay by inductively coupled plasma mass spectrometry ICP/MS

    International Nuclear Information System (INIS)

    Wyse, E.J.; Fisher, D.R.

    1993-04-01

    The determination of plutonium in urine poses several analytical challenges, e.g., detectability, matrix, etc. We have investigated the feasibility of analyzing plutonium in processed urine by inductively coupled plasma mass spectrometry (ICP/MS). The urine samples are first spiked with 244 Pu as a tracer and internal standard, then processed by co-precipitation and column chromatography using TRU-Spec trademark, an extraction resin. By enhancing ICP/MS detection capabilities via improved sample introduction and data acquisition efficiencies, an instrumental detection limit of 5 to 50 fg (0.3 to 3 fCi for 239 pu) is typically obtained, depending on the desired degree of quantitation. A brief summary of the analytical method as well as the basis for measuring radionuclides by ICP/MS are submitted; the separation procedure, methods of sample introduction, and data acquisition techniques are then highlighted

  9. Selective quantitation of the neurotoxin BMAA by use of hydrophilic-interaction liquid chromatography-differential mobility spectrometry-tandem mass spectrometry (HILIC-DMS-MS/MS).

    Science.gov (United States)

    Beach, Daniel G; Kerrin, Elliott S; Quilliam, Michael A

    2015-11-01

    The neurotoxin β-N-methylamino-L-alanine (BMAA) has been reported in cyanobacteria and shellfish, raising concerns about widespread human exposure. However, inconsistent results for BMAA analysis have led to controversy. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is the most appropriate method for analysis of BMAA, but the risk of interference from isomers, other sample components, and the electrospray background is still present. We have investigated differential mobility spectrometry (DMS) as an ion filter to improve selectivity in the hydrophilic interaction liquid chromatographic (HILIC)-MS/MS determination of BMAA. We obtained standards for two BMAA isomers not previously analyzed by HILIC-MS, β-amino-N-methylalanine and 3,4-diaminobutanoic acid, and the typically used 2,4-diaminobutanoic acid and N-(2-aminoethyl)glycine. DMS separation of BMAA from these isomers was achieved and optimized conditions were used to develop a sensitive and highly selective multidimensional HILIC-DMS-MS/MS method. This work revealed current technical limitations of DMS for trace quantitation, and practical solutions were implemented. Accurate control of low levels of DMS carrier gas modifier was essential, but required external metering. The linearity of our optimized method was excellent from 0.01 to 6 μmol L(-1). The instrumental LOD was 0.4 pg BMAA injected on-column and the estimated method LOD was 20 ng g(-1) dry weight for BMAA in sample matrix. The method was used to analyze cycad plant tissue, a cyanobacterial reference material, and mussel tissues, by use of isotope-dilution quantitation with deuterated BMAA. This confirmed the presence of BMAA and several of its isomers in cycad and mussel tissues, including commercially available mussel tissue reference materials certified for other biotoxins. Graphical Abstract Differential Mobility Spectrometry is used to increases the selectivity of BMAA analysis by HILIC-MS/MS.

  10. Differentiation of Vitis vinifera varieties by MALDI-MS analysis of the grape seed proteins.

    Science.gov (United States)

    Pesavento, Ivana Chiara; Bertazzo, Antonella; Flamini, Riccardo; Vedova, Antonio Dalla; De Rosso, Mirko; Seraglia, Roberta; Traldi, Pietro

    2008-02-01

    Until now the study of pathogenic related proteins in grape juice and wine, performed by ESI-MS, LC/ESI-MS, and MALDI/MS, has been proposed for differentiation of varieties. In fact, chitinases and thaumatin-like proteins persist through the vinification process and cause hazes and sediments in bottled wines. An additional instrument, potentially suitable for the grape varieties differentiation, has been developed by MALDI/MS for the grape seed protein analysis. The hydrosoluble protein profiles of seeds extract from three different Vitis vinifera grape (red and white) varieties were analyzed and compared. In order to evaluate the environmental conditions and harvest effects, the seed protein profiles of one grape variety from different locations and harvests were studied. (c) 2008 John Wiley & Sons, Ltd.

  11. Obsidian provenance studies in archaeology: A comparison between PIXE, ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Bellot-Gurlet, Ludovic; Poupeau, Gerard; Salomon, Joseph; Calligaro, Thomas; Moignard, Brice; Dran, Jean-Claude; Barrat, Jean-Alix; Pichon, Laurent

    2005-01-01

    Elemental composition fingerprinting by PIXE technique is very attractive for obsidian provenance studies as it may proceed in a non-destructive mode, even if a more complete elemental characterization can be obtained by ICP-MS and/or ICP-AES. Only few studies have compared results obtained by both methods for solid rock samples. In this work, elemental compositions were determined by ICP-MS/-AES for international geochemical standards and by ICP-MS/-AES and PIXE for inter-laboratory reference obsidians. In addition 49 obsidian source samples and artefacts were analysed by both ICP-MS/-AES and PIXE. Instrumental work and measurement quality control performed for obsidian chemical characterization, underline that PIXE and ICP-MS/-AES provide reproducible, accurate and comparable measurements. In some volcanic districts the limited number of elements dosed by PIXE is sufficient for the discrimination of the potential raw sources of obsidians. Therefore, PIXE can be an advantageous substitute to ICP-MS/-AES techniques for provenance studies

  12. APPLICATILITY OF THE VISCERAL ADIPOSITY INDEX (VAI) IN THE PREDICTION OF THE COMPONENTS OF THE METABOLIC SYNDROME IN ELDERLY.

    Science.gov (United States)

    Goldani, Heloisa; Adami, Fernanda Scherer; Antunes, Maria Terezinha; Rosa, Luis Henrique; Fassina, Patrícia; Quevedo Grave, Magali Terezinha; Morelo Dal Bosco, Simone

    2015-10-01

    The nutritional assessment may detect a state of malnutrition, overweight and cardiometabolic risk in the elderly. Easy to apply instruments enable the identification of risk factors for cardiovascular diseases (CVD). to analyze the applicability of Visceral Adiposity Index (VAI) in the prediction of MS components in the elderly. cross-sectional study with 221 elderly at a mean age of 70.65 ± 7.34 years; 53.4% female and 46.4% male. Weight, height, waist circumference (WC), fasting glucose, triglycerides (TG), total cholesterol (TC), HDL cholesterol (HDL-C), LDL cholesterol (LDL-C), and blood pressure (BP), data was obtained, as well as information about lifestyle. There were calculated the Body Mass Index (BMI), the Waist-Hip Ratio (WHR), and the VAI. The adiposity measures were compared with the components of MS, and for the VAI there was determined the capability of predicting the occurrence of MS components. by analyzing the association among the biochemical and pressoric variables and MS components with the anthropometric indicators of obesity, there was a direct and significant correlation of the BMI, the weight and the VAI with blood glucose, HDL and TG (p. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  13. A Collaborative Study: Determination of Mycotoxins in Corn, Peanut Butter, and Wheat Flour Using Stable Isotope Dilution Assay (SIDA) and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).

    Science.gov (United States)

    Zhang, Kai; Schaab, Matthew R; Southwood, Gavin; Tor, Elizabeth R; Aston, Linda S; Song, Wenlu; Eitzer, Brian; Majumdar, Sanghamitra; Lapainis, Theodore; Mai, Huy; Tran, Kevin; El-Demerdash, Aref; Vega, Victor; Cai, Yanxuan; Wong, Jon W; Krynitsky, Alexandra J; Begley, Timothy H

    2017-08-23

    A collaborative study was conducted to evaluate stable isotope dilution assay (SIDA) and LC-MS/MS for the simultaneous determination of aflatoxins B 1 , B 2 , G 1 , and G 2 ; deoxynivalenol; fumonisins B 1 , B 2 , and B 3 ; ochratoxin A; HT-2 toxin; T-2 toxin; and zearalenone in foods. Samples were fortified with 12 13 C uniformly labeled mycotoxins ( 13 C-IS) corresponding to the native mycotoxins and extracted with acetonitrile/water (50:50 v/v), followed by centrifugation, filtration, and LC-MS/MS analysis. In addition to certified reference materials, the six participating laboratories analyzed corn, peanut butter, and wheat flour fortified with the 12 mycotoxins at concentrations ranging from 1.0 to 1000 ng/g. Using their available LC-MS/MS platform, each laboratory developed in-house instrumental conditions for analysis. The majority of recoveries ranged from 80 to 120% with relative standard derivations (RSDs) <20%. Greater than 90% of the average recoveries of the participating laboratories were in the range of 90-110%, with repeatability RSD r (within laboratory) < 10% and reproducibility RSD R (among laboratory) < 15%. All Z scores of the results of certified reference materials were between -2 and 2. Using 13 C-IS eliminated the need for matrix-matched calibration standards for quantitation, simplified sample preparation, and achieved simultaneous identification and quantitation of multiple mycotoxins in a simple LC-MS/MS procedure.

  14. PTR-MS as a technique for investigating stress induced emission of biogenic VOCS

    International Nuclear Information System (INIS)

    Beauchamp, J.; Hansel, A.; Wisthaler, A.; Kleist, E.; Miebach, M.; Weller, U.; Wildt, J.

    2004-01-01

    Proton-transfer-reaction mass spectrometry (PTR-MS) was used in conjunction with two GC-MS systems to investigate stress induced emissions of volatile organic compounds (VOCs) from plants. Experiments were performed in the laboratory under well defined conditions and VOC emissions were induced by ozone exposure at variable concentrations and for different durations. Tobacco (Nicotiana tabaccum cv. Bel W3) plants were used as the investigated species. This investigation demonstrated the ability of PTR-MS to provide excellent high time-resolution on-line measurements of the relevant species. The combination of the PTR-MS instrument with the two GC-MS systems (which enabled accurate compound identification) allowed for detailed investigation of the dynamics of the plants' responses to ozone stress. VOCs measured included methanol, C6- alcohols and aldehydes, methyl salicylate and sesquiterpenes. Results indicate that the temporal stress response of plants depend on the amount of stress encountered by the plant. Measurement technique and experimental results will be presented. (author)

  15. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  16. Predicted summary of panel discussion on smart instruments

    International Nuclear Information System (INIS)

    Sorber, R.E.

    1991-01-01

    The following is a hypothetical account of a panel discussion on Smart Instruments. It enumerates topics that are likely to covered in the actual discussion. A smart instrument may be defined as one that performs smart functions or as one that contains a computer of some sort. Neither definition is perfect. Smart functions might include, but are not limited to: automated data logging (reading, location, time); transfer (downloading) logged data to outside computer; computer assisted, remote calibration; linearity and dead time correction; performance trending; self diagnosis of faults; detector probe recognition; automated beta factor application; and automatic range selection. These smart functions are discussed

  17. Dansyl-peptides matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) and tandem mass spectrometric (MS/MS) features improve the liquid chromatography/MALDI-MS/MS analysis of the proteome.

    Science.gov (United States)

    Chiappetta, Giovanni; Ndiaye, Sega; Demey, Emmanuelle; Haddad, Iman; Marino, Gennaro; Amoresano, Angela; Vinh, Joëlle

    2010-10-30

    Peptide tagging is a useful tool to improve matrix-assisted laser desorption/ionization tandem mass spectrometric (MALDI-MS/MS) analysis. We present a new application of the use of the dansyl chloride (DNS-Cl). DNS-Cl is a specific primary amine reagent widely used in protein biochemistry. It adds a fluorescent dimethylaminonaphthalene moiety to the molecule. The evaluation of MALDI-MS and MS/MS analyses of dansylated peptides shows that dansylation raises the ionization efficiency of the most hydrophilic species compared with the most hydrophobic ones. Consequently, higher Mascot scores and protein sequence coverage are obtained by combining MS and MS/MS data of native and tagged samples. The N-terminal DNS-Cl sulfonation improves the peptide fragmentation and promotes the generation of b-fragments allowing better peptide sequencing. In addition, we set up a labeling protocol based on the microwave chemistry. Peptide dansylation proved to be a rapid and cheap method to improve the performance of liquid chromatography (LC)/MALDI-MS/MS analysis at the proteomic scale in terms of peptide detection and sequence coverage. Copyright © 2010 John Wiley & Sons, Ltd.

  18. Metabolite signal identification in accurate mass metabolomics data with MZedDB, an interactive m/z annotation tool utilising predicted ionisation behaviour 'rules'

    Directory of Open Access Journals (Sweden)

    Snowdon Stuart

    2009-07-01

    Full Text Available Abstract Background Metabolomics experiments using Mass Spectrometry (MS technology measure the mass to charge ratio (m/z and intensity of ionised molecules in crude extracts of complex biological samples to generate high dimensional metabolite 'fingerprint' or metabolite 'profile' data. High resolution MS instruments perform routinely with a mass accuracy of Results Metabolite 'structures' harvested from publicly accessible databases were converted into a common format to generate a comprehensive archive in MZedDB. 'Rules' were derived from chemical information that allowed MZedDB to generate a list of adducts and neutral loss fragments putatively able to form for each structure and calculate, on the fly, the exact molecular weight of every potential ionisation product to provide targets for annotation searches based on accurate mass. We demonstrate that data matrices representing populations of ionisation products generated from different biological matrices contain a large proportion (sometimes > 50% of molecular isotopes, salt adducts and neutral loss fragments. Correlation analysis of ESI-MS data features confirmed the predicted relationships of m/z signals. An integrated isotope enumerator in MZedDB allowed verification of exact isotopic pattern distributions to corroborate experimental data. Conclusion We conclude that although ultra-high accurate mass instruments provide major insight into the chemical diversity of biological extracts, the facile annotation of a large proportion of signals is not possible by simple, automated query of current databases using computed molecular formulae. Parameterising MZedDB to take into account predicted ionisation behaviour and the biological source of any sample improves greatly both the frequency and accuracy of potential annotation 'hits' in ESI-MS data.

  19. An UPLC-MS/MS method for highly sensitive high-throughput analysis of phytohormones in plant tissues

    Directory of Open Access Journals (Sweden)

    Balcke Gerd Ulrich

    2012-11-01

    Full Text Available Abstract Background Phytohormones are the key metabolites participating in the regulation of multiple functions of plant organism. Among them, jasmonates, as well as abscisic and salicylic acids are responsible for triggering and modulating plant reactions targeted against pathogens and herbivores, as well as resistance to abiotic stress (drought, UV-irradiation and mechanical wounding. These factors induce dramatic changes in phytohormone biosynthesis and transport leading to rapid local and systemic stress responses. Understanding of underlying mechanisms is of principle interest for scientists working in various areas of plant biology. However, highly sensitive, precise and high-throughput methods for quantification of these phytohormones in small samples of plant tissues are still missing. Results Here we present an LC-MS/MS method for fast and highly sensitive determination of jasmonates, abscisic and salicylic acids. A single-step sample preparation procedure based on mixed-mode solid phase extraction was efficiently combined with essential improvements in mobile phase composition yielding higher efficiency of chromatographic separation and MS-sensitivity. This strategy resulted in dramatic increase in overall sensitivity, allowing successful determination of phytohormones in small (less than 50 mg of fresh weight tissue samples. The method was completely validated in terms of analyte recovery, sensitivity, linearity and precision. Additionally, it was cross-validated with a well-established GC-MS-based procedure and its applicability to a variety of plant species and organs was verified. Conclusion The method can be applied for the analyses of target phytohormones in small tissue samples obtained from any plant species and/or plant part relying on any commercially available (even less sensitive tandem mass spectrometry instrumentation.

  20. Temporal variation of gravity field prior to the Ludian Ms6.5 and Kangding Ms6.3 earthquakes

    Directory of Open Access Journals (Sweden)

    Hongtao Hao

    2015-11-01

    Full Text Available Using mobile gravity data from the central area of Sichuan and Yunnan Provinces, the relationship between gravity variation and earthquakes was studied based on the Ludian Ms6.5 earthquake that occurred on August 3rd, 2014, and the Kangding Ms6.3 earthquake that occurred on November 22nd, 2014; the mechanism of gravity variation was also explored. The results are as follows: (1 Prior to both earthquakes, gravity variation exhibited similar characteristics as those observed before both the Tangshan and Wenchuan earthquakes, in which typical precursor anomalies were positive gravity variation near the epicenter and the occurrence of a high-gravity-gradient zone across the epicenter prior to the earthquake. (2 A relatively accurate prediction of the occurrence locations of the two earthquakes was made by the Gravity Network Center of China (GNCC based on these precursor anomalies. In the gravity study report on the 2014 earthquake trends submitted at the end of 2013, the Daofu-Shimian section at the junction of the Xianshuihe and Longmenshan fault zones was noted as an earthquake-risk region with a predicted magnitude of 6.5, which covered the epicenter of the Kangding Ms6.3 earthquake. In another report on earthquake trends in southwestern China submitted in mid-2014, the Lianfeng, Zhaotong fault zone was also classified as an earthquake-risk region with a magnitude of 6.0, and the central area of this region basically overlapped with the epicenter of the Ludian Ms6.5 earthquake. (3 The gravity variation characteristics are reasonably consistent with crustal movements, and deep material migration is likely the primary cause of gravity variation.

  1. MALDI-TOF MS/MS measurements of PMMA

    NARCIS (Netherlands)

    Becer, C.R.; Baumgaertel, A.; Gottschaldt, M.; Schubert, U.S.

    2008-01-01

    The polymer poly(Me methacrylate) (PMMA) was analyzed using the matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) technique. The MALDI-TOF MS app. was coupled with a collision-induced dissocn. (CID) unit. The performance of the MALDI-TOF/TOF MS method in

  2. MALDI-MS drug analysis in biological samples: opportunities and challenges.

    Science.gov (United States)

    Steuer, Andrea E; Poetzsch, Michael; Kraemer, Thomas

    2016-09-01

    Drug analysis represents a large field in different disciplines. Plasma is commonly considered to be the biosample of choice for that purpose. However, concentrations often do not represent the levels present within deeper compartments and therefore cannot sufficiently explain efficacy or toxicology of drugs. MALDI-MS in drug analysis is of great interest for high-throughput quantification and particularly spatially resolved tissue imaging. The current perspective article will deal with challenges and opportunities of MALDI-MS drug analysis in different biological samples. A particular focus will be on hair samples. Recent applications were included, reviewed for their instrumental setup and sample preparation and pros and cons as well as future perspectives are critically discussed.

  3. Predicting falls using two instruments (the Hendrich Fall Risk Model and the Morse Fall Scale) in an acute care setting in Lebanon.

    Science.gov (United States)

    Nassar, Nada; Helou, Nancy; Madi, Chantal

    2014-06-01

    To assess the predictive value of two instruments (the Morse Fall Scale (MFS) and the Heindrich II Fall Risk Model (HFRM)] in a Middle Eastern country (Lebanon) and to evaluate the factors that are related to falls. A prospective observational cross-sectional design was used. Falls and fall-related injuries in the acute care settings contribute a substantial health and economic burden on patients and organisations. Preventing falls is a priority for most healthcare organisations. While the risk of falling cannot be eliminated, it can be significantly reduced through accurate assessment of patients' risk of falling. Data from 1815 inpatients at the American University of Beirut Medical Center (AUBMC) in Lebanon were evaluated using two instruments to predict falls: the MFS and the HFRM. The incidence of falls was 2·7% in one year. The results indicate that while the instruments were significantly correlated, the HFRM was more sensitive in predicting falls than the MFS. The internal consistency of both scales was moderate, but inter-rater reliability was high. Patients using antiepileptic drugs and assistance devises had higher odds of falling. Although both instruments were easy to use in a Middle Eastern country, the HFRM rather than the MFS is recommended for inpatients in an acute care setting as it had higher sensitivity and specificity. It is recommended that while the HFRM had adequate sensitivity, it is not seamless, and as such, nurses should not rely entirely on it. Rather, nurses should use their expert clinical judgement, their ethical obligations and cultural considerations to implement a safer environment of care for the patient. © 2013 John Wiley & Sons Ltd.

  4. Misleading measures in Vitamin D analysis: A novel LC-MS/MS assay to account for epimers and isobars

    Directory of Open Access Journals (Sweden)

    Petroczi Andrea

    2011-05-01

    Full Text Available Abstract Background Recently, the accuracies of many commercially available immunoassays for Vitamin D have been questioned. Liquid chromatography tandem mass spectrometry (LC- MS/MS has been shown to facilitate accurate separation and quantification of the major circulating metabolite 25-hydroxyvitamin-D3 (25OHD3 and 25-hydroxyvitamin-D2 (25OHD2 collectively termed as 25OHD. However, among other interferents, this method may be compromised by overlapping peaks and identical masses of epimers and isobars, resulting in inaccuracies in circulating 25OHD measurements. The aim of this study was to develop a novel LC-MS/MS method that can accurately identify and quantitate 25OHD3 and 25OHD2 through chromatographic separation of 25OHD from its epimers and isobars. Methods A positive ion electrospray ionisation (ESI LC-MS/MS method was used in the Multiple Reaction Monitoring (MRM mode for quantification. It involved i liquid-liquid extraction, ii tandem columns (a high resolution ZORBAX C18 coupled to an ULTRON chiral, with guard column and inlet filter, iii Stanozolol-D3 as internal standard, and iv identification via ESI and monitoring of three fragmentation transitions. To demonstrate the practical usefulness of our method, blood samples were collected from 5 healthy male Caucasian volunteers; age range 22 to 37 years and 25OHD2, 25OHD3 along with co-eluting epimers and analogues were quantified. Results The new method allowed chromatographic separation and quantification of 25OHD2, 25OHD3, along with 25OHD3 epimer 3-epi-25OHD3 and isobars 1-α-hydroxyvitamin-D3 (1αOHD3, and 7-α-hydroxy-4-cholesten-3-one (7αC4. The new assay was capable of detecting 0.25 ng/mL of all analytes in serum. Conclusions To our knowledge, this is the first specific, reliable, reproducible and robust LC-MS/MS method developed for the accurate detection of 25OHD (Vitamin D. The method is capable of detecting low levels of 25OHD3 and 25OHD2 together with chromatographic

  5. Quantification of pharmaceutical peptides in human plasma by LC-ICP-MS sulfur detection

    DEFF Research Database (Denmark)

    Møller, Laura Hyrup; Macherius, André; Hansen, Thomas Hesselhøj

    2016-01-01

    A method for quantification of a pharmaceutical peptide in human plasma was developed using gradient elution LC-ICP-MS. A membrane desolvation (MD) system was applied to remove organic solvents from the eluent prior to the detection as SO+ in the dynamic reaction cell (DRC) of the ICP-DRC-MS inst......A method for quantification of a pharmaceutical peptide in human plasma was developed using gradient elution LC-ICP-MS. A membrane desolvation (MD) system was applied to remove organic solvents from the eluent prior to the detection as SO+ in the dynamic reaction cell (DRC) of the ICP......-DRC-MS instrument and subsequent quantification by post-column isotope dilution (IDA). Plasma proteins were precipitated prior to analysis. Analytical figures of merit including linearity, precision, LOD, LOQ and accuracy were considered satisfactory for analysis of plasma samples. The selectivity of the developed...... method was demonstrated for five pharmaceutically relevant peptides: desmopressin, penetratin, substance P, PTH (1-34) and insulin. Preliminary experiments on an ICP-MS/MS system using oxygen to reduce the effect of organic solvents were also performed to compare sensitivity. The results of the study...

  6. Instrumentation in Heavy Water Plant at Hazira (Paper No. 3.1)

    International Nuclear Information System (INIS)

    Mistry, I.L.

    1992-01-01

    Heavy Water Plant at Hazira is based on monothermal ammonia-hydrogen exchange process and is hooked up to the two, 1350 T/day ammonia plants of M/s. KRIBHCO. An attempt is being made to highlight the salient features of instrumentation, philosophy of selection, brief description of the control system, operational experience, problems faced during commissioning and plant operation and few suggestions to improve the working and reliability of the instrumentation. (author)

  7. Effects of Gas-Wall Partitioning in Teflon Tubing, Instrumentation and Other Materials on Time-Resolved Measurements of Gas-Phase Organic Compounds

    Science.gov (United States)

    Pagonis, D.; Deming, B.; Krechmer, J. E.; De Gouw, J. A.; Jimenez, J. L.; Ziemann, P. J.

    2017-12-01

    Recently it has been shown that gas-phase organic compounds partition to and from the walls of Teflon environmental chambers. This process is fast, reversible, and can be modeled as absorptive partitioning. Here these studies were extended to investigate gas-wall partitioning inside Teflon tubing by introducing step function changes in the concentration of compounds being sampled and measuring the delay in the response of a proton transfer reaction-mass spectrometer (PTR-MS). We find that these delays are significant for compounds with a saturation vapor concentration (c*) below 106 μg m-3, and that the Teflon tubing and the PTR-MS both contribute to the delays. Tubing delays range from minutes to hours under common sampling conditions and can be accurately predicted by a simple chromatography model across a range of tubing lengths and diameters, flow rates, compound functional groups, and c*. This method also allows one to determine the volatility-dependent response function of an instrument, which can be convolved with the output of the tubing model to correct for delays in instrument response time for these "sticky" compounds. This correction is expected to be of particular interest to researchers utilizing and developing chemical ionization mass spectrometry (CIMS) techniques, since many of the multifunctional organic compounds detected by CIMS show significant tubing and instrument delays. These results also enable better design of sampling systems, in particular when fast instrument response is needed, such as for rapid transients, aircraft, or eddy covariance measurements. Additional results presented here extend this method to quantify the relative sorptive capacities for other commonly used tubing materials, including PFA, FEP, PTFE, PEEK, glass, copper, stainless steel, and passivated steel.

  8. Direct concurrent comparison of multiple pediatric acute asthma scoring instruments.

    Science.gov (United States)

    Johnson, Michael D; Nkoy, Flory L; Sheng, Xiaoming; Greene, Tom; Stone, Bryan L; Garvin, Jennifer

    2017-09-01

    Appropriate delivery of Emergency Department (ED) treatment to children with acute asthma requires clinician assessment of acute asthma severity. Various clinical scoring instruments exist to standardize assessment of acute asthma severity in the ED, but their selection remains arbitrary due to few published direct comparisons of their properties. Our objective was to test the feasibility of directly comparing properties of multiple scoring instruments in a pediatric ED. Using a novel approach supported by a composite data collection form, clinicians categorized elements of five scoring instruments before and after initial treatment for 48 patients 2-18 years of age with acute asthma seen at the ED of a tertiary care pediatric hospital ED from August to December 2014. Scoring instruments were compared for inter-rater reliability between clinician types and their ability to predict hospitalization. Inter-rater reliability between clinician types was not different between instruments at any point and was lower (weighted kappa range 0.21-0.55) than values reported elsewhere. Predictive ability of most instruments for hospitalization was higher after treatment than before treatment (p < 0.05) and may vary between instruments after treatment (p = 0.054). We demonstrate the feasibility of comparing multiple clinical scoring instruments simultaneously in ED clinical practice. Scoring instruments had higher predictive ability for hospitalization after treatment than before treatment and may differ in their predictive ability after initial treatment. Definitive conclusions about the best instrument or meaningful comparison between instruments will require a study with a larger sample size.

  9. Geotechnical instrumentation for repository shafts

    International Nuclear Information System (INIS)

    Lentell, R.L.; Byrne, J.

    1993-01-01

    The US Congress passed the Nuclear Waste Policy Act in 1980, which required that three distinctly different geologic media be investigated as potential candidate sites for the permanent disposal of high-level nuclear waste. The three media that were selected for study were basalt (WA), salt (TX, LA, MS, UT), and tuff (NV). Preliminary Exploratory Shaft Facilities (ESF) designs were prepared for seven candidate salt sites, including bedded and domal salt environments. A bedded-salt site was selected in Deaf Smith County, TX for detailed site characterization studies and ESF Final Design. Although Congress terminated the Salt Repository Program in 1988, Final Design for the Deaf Smith ESF was completed, and much of the design rationale can be applied to subsequent deep repository shafts. This paper presents the rationale for the geotechnical instrumentation that was designed for construction and operational performance monitoring of the deep shafts of the in-situ test facility. The instrumentation design described herein can be used as a general framework in designing subsequent instrumentation programs for future high-level nuclear waste repository shafts

  10. LC-MS (/MS) in clinical toxicology screening methods.

    Science.gov (United States)

    Viette, Véronique; Hochstrasser, Denis; Fathi, Marc

    2012-01-01

    Toxicological screening is the analysis of biological samples to detect and identify unknown compounds. The high selectivity and sensitivity of liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) technology provide an attractive alternative to the current methods (LC-UV, GC/MS, etc.). For these reasons, an increasing number of applications are being published. This paper is a brief overview of LC-MS(/MS) screening methods developed for clinical toxicology in recent years. Various sample treatments, chromatographic separations and detection by mass spectrometry can be combined to obtain screening methods adapted to the constraints and needs of clinical toxicology laboratories. Currently the techniques are in the hands of specialists, mainly in academic institutions. However, the evolution in technology should allow application of these techniques as a tool in toxicology laboratories, thus allowing a more widespread exploitation of their potential.

  11. A postprocessing method in the HMC framework for predicting gene function based on biological instrumental data

    Science.gov (United States)

    Feng, Shou; Fu, Ping; Zheng, Wenbin

    2018-03-01

    Predicting gene function based on biological instrumental data is a complicated and challenging hierarchical multi-label classification (HMC) problem. When using local approach methods to solve this problem, a preliminary results processing method is usually needed. This paper proposed a novel preliminary results processing method called the nodes interaction method. The nodes interaction method revises the preliminary results and guarantees that the predictions are consistent with the hierarchy constraint. This method exploits the label dependency and considers the hierarchical interaction between nodes when making decisions based on the Bayesian network in its first phase. In the second phase, this method further adjusts the results according to the hierarchy constraint. Implementing the nodes interaction method in the HMC framework also enhances the HMC performance for solving the gene function prediction problem based on the Gene Ontology (GO), the hierarchy of which is a directed acyclic graph that is more difficult to tackle. The experimental results validate the promising performance of the proposed method compared to state-of-the-art methods on eight benchmark yeast data sets annotated by the GO.

  12. Improving Student Understanding of Qualitative and Quantitative Analysis via GC/MS Using a Rapid SPME-Based Method for Determination of Trihalomethanes in Drinking Water

    Science.gov (United States)

    Huang, Shu Rong; Palmer, Peter T.

    2017-01-01

    This paper describes a method for determination of trihalomethanes (THMs) in drinking water via solid-phase microextraction (SPME) GC/MS as a means to develop and improve student understanding of the use of GC/MS for qualitative and quantitative analysis. In the classroom, students are introduced to SPME, GC/MS instrumentation, and the use of MS…

  13. Mapping the Subcellular Proteome of Shewanella oneidensis MR-1 using Sarkosyl-based fractionation and LC-MS/MS protein identification

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Roslyn N.; Romine, Margaret F.; Schepmoes, Athena A.; Smith, Richard D.; Lipton, Mary S.

    2010-07-19

    A simple and effective subcellular proteomic method for fractionation and analysis of gram-negative bacterial cytoplasm, periplasm, inner, and outer membranes was applied to Shewanella oneidensis to gain insight into its subcellular architecture. A combination of differential centrifugation, Sarkosyl solubilization, and osmotic lysis was used to prepare subcellular fractions. Global differences in protein fractions were observed by SDS PAGE and heme staining, and tryptic peptides were analyzed using high-resolution LC-MS/MS. Compared to crude cell lysates, the fractionation method achieved a significant enrichment (average ~2-fold) in proteins predicted to be localized to each subcellular fraction. Compared to other detergent, organic solvent, and density-based methods previously reported, Sarkosyl most effectively facilitated separation of the inner and outer membranes and was amenable to mass spectrometry, making this procedure ideal for probing the subcellular proteome of gram-negative bacteria via LC-MS/MS. With 40% of the observable proteome represented, this study has provided extensive information on both subcellular architecture and relative abundance of proteins in S. oneidensis and provides a foundation for future work on subcellular organization and protein-membrane interactions in other gram-negative bacteria.

  14. Analysis of acrylamide by LC-MS/MS and GC-MS in processed Japanese foods.

    Science.gov (United States)

    Ono, H; Chuda, Y; Ohnishi-Kameyama, M; Yada, H; Ishizaka, M; Kobayashi, H; Yoshida, M

    2003-03-01

    Acrylamide concentrations in processed foods (63 samples covering 31 product types) from Japan were analysed by LC-MS/MS and GC-MS methods. The limit of detection and limit of quantification of acrylamide were 0.2 ng x ml(-1) (6 fmol) and 0.8 ng x ml(-1) (22 fmol), respectively, by LC-MS/MS, and those of 2,3-dibromopropionamide derived from acrylamide were 12 ng x ml(-1) (52 fmol) and 40 ng x ml(-1) (170 fmol), respectively, by GC-MS. Repeatability given as RSD was 1000 microg x kg(-1). The concentrations in non-whole potato-based snacks, rice crackers processed by grilling or frying, and candied sweet potatoes were lower compared with those in the potato crisps and the whole potato-based fried snacks. One of the whole potato-based fried snacks, however, showed low acrylamide concentration (instant precooked noodles and won-tons were <100 microg x kg(-1) with only one exception. Roasted barley grains for 'Mugi-cha' tea contained 200-600 microg x kg(-1) acrylamide.

  15. THOR Ion Mass Spectrometer instrument - IMS

    Science.gov (United States)

    Retinò, Alessandro; Kucharek, Harald; Saito, Yoshifumi; Fraenz, Markus; Verdeil, Christophe; Leblanc, Frederic; Techer, Jean-Denis; Jeandet, Alexis; Macri, John; Gaidos, John; Granoff, Mark; Yokota, Shoichiro; Fontaine, Dominique; Berthomier, Matthieu; Delcourt, Dominique; Kistler, Lynn; Galvin, Antoniette; Kasahara, Satoshi; Kronberg, Elena

    2016-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. Specifically, THOR will study how turbulent fluctuations at kinetic scales heat and accelerate particles in different turbulent environments within the near-Earth space. To achieve this goal, THOR payload is being designed to measure electromagnetic fields and particle distribution functions with unprecedented resolution and accuracy. Here we present the Ion Mass Spectrometer (IMS) instrument that will measure the full three-dimensional distribution functions of near-Earth main ion species (H+, He+, He++ and O+) at high time resolution (~ 150 ms for H+ , ~ 300 ms for He++) with energy resolution down to ~ 10% in the range 10 eV/q to 30 keV/q and angular resolution ~ 10°. Such high time resolution is achieved by mounting multiple sensors around the spacecraft body, in similar fashion to the MMS/FPI instrument. Each sensor combines a top-hat electrostatic analyzer with deflectors at the entrance together with a time-of-flight section to perform mass selection. IMS electronics includes a fast sweeping high voltage board that is required to make measurements at high cadence. Ion detection includes Micro Channel Plates (MCP) combined with Application-Specific Integrated Circuits (ASICs) for charge amplification, discrimination and time-to-digital conversion (TDC). IMS is being designed to address many of THOR science requirements, in particular ion heating and acceleration by turbulent fluctuations in foreshock, shock and magnetosheath regions. The IMS instrument is being designed and will be built by an international consortium of scientific institutes with main hardware contributions from France, USA, Japan and Germany.

  16. Formaldehyde measurements by Proton transfer reaction – Mass Spectrometry (PTR-MS: correction for humidity effects

    Directory of Open Access Journals (Sweden)

    A. Vlasenko

    2010-08-01

    Full Text Available Formaldehyde measurements can provide useful information about photochemical activity in ambient air, given that HCHO is formed via numerous oxidation processes. Proton transfer reaction mass spectrometry (PTR-MS is an online technique that allows measurement of VOCs at the sub-ppbv level with good time resolution. PTR-MS quantification of HCHO is hampered by the humidity dependence of the instrument sensitivity, with higher humidity leading to loss of PTR-MS signal. In this study we present an analytical, first principles approach to correct the PTR-MS HCHO signal according to the concentration of water vapor in sampled air. The results of the correction are validated by comparison of the PTR-MS results to those from a Hantzsch fluorescence monitor which does not have the same humidity dependence. Results are presented for an intercomparison made during a field campaign in rural Ontario at Environment Canada's Centre for Atmospheric Research Experiments.

  17. Urinary amino acid analysis: a comparison of iTRAQ-LC-MS/MS, GC-MS, and amino acid analyzer.

    Science.gov (United States)

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J

    2009-07-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27+/-5.22, 21.18+/-10.94, and 18.34+/-14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39+/-5.35, 6.23+/-3.84, and 35.37+/-29.42. Both GC-MS and iTRAQ-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.

  18. Steam 80 steam generator instrumentation

    International Nuclear Information System (INIS)

    Carson, W.H.; Harris, H.H.

    1980-01-01

    This paper describes two special instrumentation packages in an integral economizer (preheater) steam generator of one of the first System 80 plants scheduled to go into commercial operation. The purpose of the instrumentation is to obtain accurate operating information from regions of the secondary side of the steam generator inaccessible to normal plant instrumentation. In addition to verification of the System 80 steam generator design predictions, the data obtained will assist in verification of steam generator thermal/hydraulic computer codes developed for generic use in the industry

  19. Urinary Amino Acid Analysis: A Comparison of iTRAQ®-LC-MS/MS, GC-MS, and Amino Acid Analyzer

    Science.gov (United States)

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L.; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J.

    2009-01-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ®-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27±5.22, 21.18±10.94, and 18.34±14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39±5.35, 6.23±3.84, and 35.37±29.42. Both GC-MS and iTRAQ®-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines. PMID:19481989

  20. A state-based probabilistic model for tumor respiratory motion prediction

    International Nuclear Information System (INIS)

    Kalet, Alan; Sandison, George; Schmitz, Ruth; Wu Huanmei

    2010-01-01

    This work proposes a new probabilistic mathematical model for predicting tumor motion and position based on a finite state representation using the natural breathing states of exhale, inhale and end of exhale. Tumor motion was broken down into linear breathing states and sequences of states. Breathing state sequences and the observables representing those sequences were analyzed using a hidden Markov model (HMM) to predict the future sequences and new observables. Velocities and other parameters were clustered using a k-means clustering algorithm to associate each state with a set of observables such that a prediction of state also enables a prediction of tumor velocity. A time average model with predictions based on average past state lengths was also computed. State sequences which are known a priori to fit the data were fed into the HMM algorithm to set a theoretical limit of the predictive power of the model. The effectiveness of the presented probabilistic model has been evaluated for gated radiation therapy based on previously tracked tumor motion in four lung cancer patients. Positional prediction accuracy is compared with actual position in terms of the overall RMS errors. Various system delays, ranging from 33 to 1000 ms, were tested. Previous studies have shown duty cycles for latencies of 33 and 200 ms at around 90% and 80%, respectively, for linear, no prediction, Kalman filter and ANN methods as averaged over multiple patients. At 1000 ms, the previously reported duty cycles range from approximately 62% (ANN) down to 34% (no prediction). Average duty cycle for the HMM method was found to be 100% and 91 ± 3% for 33 and 200 ms latency and around 40% for 1000 ms latency in three out of four breathing motion traces. RMS errors were found to be lower than linear and no prediction methods at latencies of 1000 ms. The results show that for system latencies longer than 400 ms, the time average HMM prediction outperforms linear, no prediction, and the more

  1. Selenium speciation analysis of Misgurnus anguillicaudatus selenoprotein by HPLC-ICP-MS and HPLC-ESI-MS/MS

    Science.gov (United States)

    Analytical methods for selenium (Se) speciation were developed using high performance liquid chromatography (HPLC) coupled to either inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionization tandem mass spectrometry (ESI-MS/MS). Separations of selenomethionine (Se-Met) and sel...

  2. MassSieve: Panning MS/MS peptide data for proteins

    OpenAIRE

    Slotta, Douglas J.; McFarland, Melinda A.; Markey, Sanford P.

    2010-01-01

    We present MassSieve, a Java-based platform for visualization and parsimony analysis of single and comparative LC-MS/MS database search engine results. The success of mass spectrometric peptide sequence assignment algorithms has led to the need for a tool to merge and evaluate the increasing data set sizes that result from LC-MS/MS-based shotgun proteomic experiments. MassSieve supports reports from multiple search engines with differing search characteristics, which can increase peptide sequ...

  3. Measuring changes in perception using the Student Perceptions of Physician-Pharmacist Interprofessional Clinical Education (SPICE) instrument.

    Science.gov (United States)

    Zorek, Joseph A; MacLaughlin, Eric J; Fike, David S; MacLaughlin, Anitra A; Samiuddin, Mohammed; Young, Rodney B

    2014-05-20

    The Student Perceptions of Physician-Pharmacist Interprofessional Clinical Education (SPICE) instrument contains 10 items, 3 factors (interprofessional teamwork and team-based practice, roles/responsibilities for collaborative practice, and patient outcomes from collaborative practice), and utilizes a five-point response scale (1 = strongly disagree, 5 = strongly agree). Given the SPICE instrument's demonstrated validity and reliability, the objective of this study was to evaluate whether it was capable of measuring changes in medical (MS) and pharmacy students' (PS) perceptions following an interprofessional education (IPE) experience. In this prospective cohort study, MS and PS completed the SPICE instrument before and after participation in a predefined IPE experience. Descriptive statistics were used to characterize students and pre-post responses. Independent samples t tests and Fisher's Exact tests were used to assess group difference in demographic variables. Mann Whitney U tests were used to assess between-group differences in item scores. Wilcoxon Signed-Rank tests were used to evaluate post-participation changes in item scores. Spearman correlations were calculated to assess associations between ordinal demographic variables and item scores, and whether the number of clinic visits completed was associated with post-test responses. Paired samples t tests were used to calculate mean score changes for each of the factors. Thirty-four MS and 15 PS were enroled. Baseline differences included age (25.3. ± 1.3 MS vs. 28.7 ± 4.4 PS; p = 0.013), years full-time employment (0.71 ± 0.97 MS vs. 4.60 ± 4.55 PS; p impact of teamwork on patient satisfaction (3.72 vs. 4.34; p location for IPE (4.06 vs. 4.34; p = 0.002). Significant increases were observed for all three factors (teamwork, p = 0.003; roles/responsibilities and patient outcomes, p < 0.001). This study demonstrated the SPICE instrument's ability to measure

  4. Do predictions from Species Sensitivity Distributions match with field data?

    International Nuclear Information System (INIS)

    Smetanová, S.; Bláha, L.; Liess, M.; Schäfer, R.B.; Beketov, M.A.

    2014-01-01

    Species Sensitivity Distribution (SSD) is a statistical model that can be used to predict effects of contaminants on biological communities, but only few comparisons of this model with field studies have been conducted so far. In the present study we used measured pesticides concentrations from streams in Germany, France, and Finland, and we used SSD to calculate msPAF (multiple substance potentially affected fraction) values based on maximum toxic stress at localities. We compared these SSD-based predictions with the actual effects on stream invertebrates quantified by the SPEAR pesticides bioindicator. The results show that the msPAFs correlated well with the bioindicator, however, the generally accepted SSD threshold msPAF of 0.05 (5% of species are predicted to be affected) severely underestimated the observed effects (msPAF values causing significant effects are 2–1000-times lower). These results demonstrate that validation with field data is required to define the appropriate thresholds for SSD predictions. - Highlights: • We validated the statistical model Species Sensitivity Distribution with field data. • Good correlation was found between the model predictions and observed effects. • But, the generally accepted threshold msPAF 0.05 severely underestimated the effects. - Comparison of the SSD-based prediction with the field data evaluated with the SPEAR pesticides index shows that SSD threshold msPAF of 0.05 severely underestimates the effects observed in the field

  5. Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations

    OpenAIRE

    Ghassan Yared

    2015-01-01

    This report introduces a novel technique that allows a safe and predictable canal negotiation, creation of a glide path and canal preparation with reciprocating nickel-titanium or stainless steel engine-driven instruments in canals where the use of rotary and the newly developed reciprocating instruments is contraindicated. In this novel technique, the instruments are used in reciprocating motion with very small angles. Hand files are not used regardless of the complexity of the canal anatomy...

  6. Reduction of Solvent Effect in Reverse Phase Gradient Elution LC-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Patrick Allen [Iowa State Univ., Ames, IA (United States)

    2005-12-17

    Quantification in liquid chromatography (LC) is becoming very important as more researchers are using LC, not as an analytical tool itself, but as a sample introduction system for other analytical instruments. The ability of LC instrumentation to quickly separate a wide variety of compounds makes it ideal for analysis of complex mixtures. For elemental speciation, LC is joined with inductively coupled plasma mass spectrometry (ICP-MS) to separate and detect metal-containing, organic compounds in complex mixtures, such as biological samples. Often, the solvent gradients required to perform complex separations will cause matrix effects within the plasma. This limits the sensitivity of the ICP-MS and the quantification methods available for use in such analyses. Traditionally, isotope dilution has been the method of choice for LC-ICP-MS quantification. The use of naturally abundant isotopes of a single element in quantification corrects for most of the effects that LC solvent gradients produce within the plasma. However, not all elements of interest in speciation studies have multiple naturally occurring isotopes; and polyatomic interferences for a given isotope can develop within the plasma, depending on the solvent matrix. This is the case for reverse phase LC separations, where increasing amounts of organic solvent are required. For such separations, an alternative to isotope dilution for quantification would be is needed. To this end, a new method was developed using the Apex-Q desolvation system (ESI, Omaha, NE) to couple LC instrumentation with an ICP-MS device. The desolvation power of the system allowed greater concentrations of methanol to be introduced to the plasma prior to destabilization than with direct methanol injection into the plasma. Studies were performed, using simulated and actual linear methanol gradients, to find analyte-internal standard (AIS) pairs whose ratio remains consistent (deviations {+-} 10%) over methanol concentration ranges of 5

  7. Olive oil sensory defects classification with data fusion of instrumental techniques and multivariate analysis (PLS-DA).

    Science.gov (United States)

    Borràs, Eva; Ferré, Joan; Boqué, Ricard; Mestres, Montserrat; Aceña, Laura; Calvo, Angels; Busto, Olga

    2016-07-15

    Three instrumental techniques, headspace-mass spectrometry (HS-MS), mid-infrared spectroscopy (MIR) and UV-visible spectrophotometry (UV-vis), have been combined to classify virgin olive oil samples based on the presence or absence of sensory defects. The reference sensory values were provided by an official taste panel. Different data fusion strategies were studied to improve the discrimination capability compared to using each instrumental technique individually. A general model was applied to discriminate high-quality non-defective olive oils (extra-virgin) and the lowest-quality olive oils considered non-edible (lampante). A specific identification of key off-flavours, such as musty, winey, fusty and rancid, was also studied. The data fusion of the three techniques improved the classification results in most of the cases. Low-level data fusion was the best strategy to discriminate musty, winey and fusty defects, using HS-MS, MIR and UV-vis, and the rancid defect using only HS-MS and MIR. The mid-level data fusion approach using partial least squares-discriminant analysis (PLS-DA) scores was found to be the best strategy for defective vs non-defective and edible vs non-edible oil discrimination. However, the data fusion did not sufficiently improve the results obtained by a single technique (HS-MS) to classify non-defective classes. These results indicate that instrumental data fusion can be useful for the identification of sensory defects in virgin olive oils. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Detection and identification of 700 drugs by multi-target screening with a 3200 Q TRAP LC-MS/MS system and library searching.

    Science.gov (United States)

    Dresen, S; Ferreirós, N; Gnann, H; Zimmermann, R; Weinmann, W

    2010-04-01

    The multi-target screening method described in this work allows the simultaneous detection and identification of 700 drugs and metabolites in biological fluids using a hybrid triple-quadrupole linear ion trap mass spectrometer in a single analytical run. After standardization of the method, the retention times of 700 compounds were determined and transitions for each compound were selected by a "scheduled" survey MRM scan, followed by an information-dependent acquisition using the sensitive enhanced product ion scan of a Q TRAP hybrid instrument. The identification of the compounds in the samples analyzed was accomplished by searching the tandem mass spectrometry (MS/MS) spectra against the library we developed, which contains electrospray ionization-MS/MS spectra of over 1,250 compounds. The multi-target screening method together with the library was included in a software program for routine screening and quantitation to achieve automated acquisition and library searching. With the help of this software application, the time for evaluation and interpretation of the results could be drastically reduced. This new multi-target screening method has been successfully applied for the analysis of postmortem and traffic offense samples as well as proficiency testing, and complements screening with immunoassays, gas chromatography-mass spectrometry, and liquid chromatography-diode-array detection. Other possible applications are analysis in clinical toxicology (for intoxication cases), in psychiatry (antidepressants and other psychoactive drugs), and in forensic toxicology (drugs and driving, workplace drug testing, oral fluid analysis, drug-facilitated sexual assault).

  9. Four Examples of Short-Term and Imminent Prediction of Earthquakes

    Science.gov (United States)

    zeng, zuoxun; Liu, Genshen; Wu, Dabin; Sibgatulin, Victor

    2014-05-01

    We show here 4 examples of short-term and imminent prediction of earthquakes in China last year. They are Nima Earthquake(Ms5.2), Minxian Earthquake(Ms6.6), Nantou Earthquake (Ms6.7) and Dujiangyan Earthquake (Ms4.1) Imminent Prediction of Nima Earthquake(Ms5.2) Based on the comprehensive analysis of the prediction of Victor Sibgatulin using natural electromagnetic pulse anomalies and the prediction of Song Song and Song Kefu using observation of a precursory halo, and an observation for the locations of a degasification of the earth in the Naqu, Tibet by Zeng Zuoxun himself, the first author made a prediction for an earthquake around Ms 6 in 10 days in the area of the degasification point (31.5N, 89.0 E) at 0:54 of May 8th, 2013. He supplied another degasification point (31N, 86E) for the epicenter prediction at 8:34 of the same day. At 18:54:30 of May 15th, 2013, an earthquake of Ms5.2 occurred in the Nima County, Naqu, China. Imminent Prediction of Minxian Earthquake (Ms6.6) At 7:45 of July 22nd, 2013, an earthquake occurred at the border between Minxian and Zhangxian of Dingxi City (34.5N, 104.2E), Gansu province with magnitude of Ms6.6. We review the imminent prediction process and basis for the earthquake using the fingerprint method. 9 channels or 15 channels anomalous components - time curves can be outputted from the SW monitor for earthquake precursors. These components include geomagnetism, geoelectricity, crust stresses, resonance, crust inclination. When we compress the time axis, the outputted curves become different geometric images. The precursor images are different for earthquake in different regions. The alike or similar images correspond to earthquakes in a certain region. According to the 7-year observation of the precursor images and their corresponding earthquake, we usually get the fingerprint 6 days before the corresponding earthquakes. The magnitude prediction needs the comparison between the amplitudes of the fingerpringts from the same

  10. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Area Donate Donate Search v What Is MS? Definition of MS What Causes MS? Who Gets MS? ... Support Personal Stories d What Is MS? d Definition of MS Myelin Immune-Mediated Disease T Cells ...

  11. Metabolic profiling of roots of liquorice (Glycyrrhiza glabra) from different geographical areas by ESI/MS/MS and determination of major metabolites by LC-ESI/MS and LC-ESI/MS/MS.

    Science.gov (United States)

    Montoro, Paola; Maldini, Mariateresa; Russo, Mariateresa; Postorino, Santo; Piacente, Sonia; Pizza, Cosimo

    2011-02-20

    Liquid chromatography electrospray mass spectrometry (LC-ESI/MS) has been applied to the full characterization of saponins and phenolics in hydroalcoholic extracts of roots of liquorice (Glycyrrhiza glabra). Relative quantitative analyses of the samples with respect to the phenolic constituents and to a group of saponins related to glycyrrhizic acid were performed using LC-ESI/MS. For the saponin constituents, full scan LC-MS/MS fragmentation of the protonated (positive ion mode) or deprotonated (negative ion mode) molecular species generated diagnostic fragment ions that provided information concerning the triterpene skeleton and the number and nature of the substituents. On the basis of the specific fragmentation of glycyrrhizic acid, an LC-MS/MS method was developed in order to quantify the analyte in the liquorice root samples. Chinese G. glabra roots contained the highest levels of glycyrrhizic acid, followed by those from Italy (Calabria). Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Volatile compound changes during shelf life of dried Boletus edulis: comparison between SPME-GC-MS and PTR-ToF-MS analysis.

    Science.gov (United States)

    Aprea, Eugenio; Romano, Andrea; Betta, Emanuela; Biasioli, Franco; Cappellin, Luca; Fanti, Marco; Gasperi, Flavia

    2015-01-01

    Drying process is commonly used to allow long time storage of valuable porcini mushrooms (Boletus edulis). Although considered a stable product dried porcini flavour changes during storage. Monitoring of volatile compounds during shelf life may help to understand the nature of the observed changes. In the present work two mass spectrometric techniques were used to monitor the evolution of volatile compounds during commercial shelf life of dried porcini. Solid phase microextraction (SPME) coupled to gas chromatography - mass spectrometry (GC-MS) allowed the identification of 66 volatile compounds, 36 of which reported for the first time, monitored during the commercial shelf life of dried porcini. Proton transfer reaction - time of flight - mass spectrometry (PTR-ToF-MS) , a direct injection mass spectrometric technique, was shown to be a fast and sensitive instrument for the general monitoring of volatile compound evolution during storage of dried porcini. Furthermore, PTR-ToF-MS grants access to compounds whose determination would otherwise require lengthy pre-concentration and/or derivatization steps such as ammonia and small volatile amines. The two techniques, both used for the first time to study dried porcini, provided detailed description of time evolution of volatile compounds during shelf life. Alcohols, aldehydes, ketones and monoterpenes diminish during the storage while carboxylic acids, pyrazines, lactones and amines increase. The storage temperature modifies the rate of the observed changes influencing the final quality of the dried porcini. We showed the advantages of both techniques, suggesting a strategy to be adopted to follow time evolution of volatile compounds in food products during shelf life, based on the identification of compounds by GC-MS and the rapid time monitoring by PTR-ToF-MS measurements in order to maximize the advantages of both techniques. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Pre-concentration technique for reduction in "Analytical instrument requirement and analysis"

    Science.gov (United States)

    Pal, Sangita; Singha, Mousumi; Meena, Sher Singh

    2018-04-01

    Availability of analytical instruments for a methodical detection of known and unknown effluents imposes a serious hindrance in qualification and quantification. Several analytical instruments such as Elemental analyzer, ICP-MS, ICP-AES, EDXRF, ion chromatography, Electro-analytical instruments which are not only expensive but also time consuming, required maintenance, damaged essential parts replacement which are of serious concern. Move over for field study and instant detection installation of these instruments are not convenient to each and every place. Therefore, technique such as pre-concentration of metal ions especially for lean stream elaborated and justified. Chelation/sequestration is the key of immobilization technique which is simple, user friendly, most effective, least expensive, time efficient; easy to carry (10g - 20g vial) to experimental field/site has been demonstrated.

  14. Adding delayed recall to the ADAS-cog improves measurement precision in mild Alzheimer's disease: Implications for predicting instrumental activities of daily living.

    Science.gov (United States)

    Lowe, Deborah A; Balsis, Steve; Benge, Jared F; Doody, Rachelle S

    2015-12-01

    As research increasingly focuses on preclinical stages of Alzheimer's disease (AD), instruments must be retooled to identify early cognitive markers of AD. A supplemental delayed recall subtest for the Alzheimer's Disease Assessment Scale-cognitive (ADAS-cog; Mohs, Rosen, & Davis, 1983; Rosen, Mohs, & Davis, 1984) is commonly implemented, but it is not known precisely where along the spectrum of cognitive dysfunction this subtest yields incremental information beyond what is gained from the standard ADAS-cog, or whether it can improve prediction of functional outcomes. An item response theory approach can analyze this in a psychometrically rigorous way. Seven hundred eighty-eight patients with AD or amnestic complaints or impairment completed a battery including the ADAS-cog and 2 activities of daily living measures. The delayed recall subtest slightly improved the ADAS-cog's measurement precision in the mild range of cognitive dysfunction and increased prediction of instrumental activities of daily living for individuals with subjective memory impairment. (c) 2015 APA, all rights reserved).

  15. Analysis of membrane proteome by data-dependent LC-MS/MS combined with data-independent LC-MSE technique

    Directory of Open Access Journals (Sweden)

    Joseph Kwon

    2010-03-01

    Full Text Available Proteomics work resembles the search for a needle in a haystack. The identification of protein biomarker requires the removal of the false protein data from the whole protein mixture. For high quality proteomic data, even a strict filtration step using the false discovery rate (FDR is insufficient for obtaining perfect protein information from the biological samples. In this study, the cyanobacterial whole membrane fraction was applied to the data-dependent analysis (DDA mode of LC-MS/MS, which was used along with the data-independent LC-MSE technique in order to evaluate the membrane proteomic data. Furthermore, the identified MSE-information (MSE-i data based on the peptide mass and the retention time were validated by the other database search, i.e., the probability-based MASCOT and de novo search engine PEAKS. In this present study, 208 cyanobacterial proteins with FDR of 5% were identified using the data-independent nano-UPLC/MSE acquisition with the Protein Lynx Global Server (PLGS, and 56 of these proteins were the predicted membrane proteins. When a total of 208 MSE-i proteomic data were applied to the DDA mode of LC-MS/MS, the number of identified membrane proteins was 26 and 33 from MASCOT and PEAKS with a FDR of 5%, respectively. The number of totally overlapped membrane proteins was 25. Therefore, the data-independent LC-MSE identified more proteins with a high confidence.

  16. Analysis of poly-beta-hydroxybutyrate in environmental samples by GC-MS/MS.

    Science.gov (United States)

    Elhottová, D; Tríska, J; Petersen, S O; Santrůcková, H

    2000-05-01

    Application of gas chromatography-mass spectrometry (GC-MS) can significantly improve trace analyses of compounds in complex matrices from natural environments compared to gas chromatography only. A GC-MS/MS technique for determination of poly-beta-hydroxybutyrate (PHB), a bacterial storage compound, has been developed and used for analysis of two soils stored for up to 319 d, fresh samples of sewage sludge, as well as a pure culture of Bacillus megaterium. Specific derivatization of beta-hydroxybutyrate (3-OH C4:0) PHB monomer units by N-tert-butyl-dimethylsilyl-N-methyltrifluoracetamide (MTBSTFA) improved chromatographic and mass spectrometric properties of the analyte. The diagnostic fragmentation scheme of the derivates tert-butyldimethylsilyl ester and ether of beta-hydroxybutyric acid (MTBSTFA-HB) essential for the PHB identification was shown. The ion trap MS was used, therefore the scan gave the best sensitivity and with MS/MS the noise decreased, so the S/N was better and also with second fragmentation the amount of ions increased compared to SIM. The detection limit for MTBSTFA-HB by GC-MS/MS was about 10(-13) g microL(-1) of injected volume, while by GC (FID) and GC-MS (scan) it was around 10(-10) g microL(-1) of injected volume. Sensitivity of GC-MS/MS measurements of PHB in arable soil and activated sludge samples was down to 10 pg of PHB g(-1) dry matter. Comparison of MTBSTFA-HB detection in natural soil sample by GC (FID), GC-MS (scan) and by GC-MS/MS demonstrated potentials and limitations of the individual measurement techniques.

  17. Ways for accurate analysis of high purity materials using the glow discharge mass spectrometry (GD-MS); Wege zur genauen Charakterisierung hochreiner Materialien mit der Glimmentladungs-Massenspektrometrie (GD-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Gusarova, Tamara

    2010-04-14

    The main aim of this work consists in the investigation, development and application of improved possibilities of accurate analysis of high purity materials using the solid sample technique of Glow Discharge Mass Spectrometry (GD-MS), as well as in the sensitivity enhancement of GD Optical Emission Spectrometry (GD-OES) by implicating the hollow cathode effect. The emphasis of the PhD thesis consists in the accurate quantification for GD-MS. As appropriate certified reference materials (CRMs) for calibration are lacking in most cases an accurate quantification especially for trace elements mass fractions at {mu}g kg{sup -1} level can often not be achieved. To overcome this problem and to expand the possibilities of modern GD-MS hereby, synthetic standards were applied for calibration of both high resolution GD-MS instruments ''VG 9000'' and ''Element GD''. The standards were prepared by doping of matrix powder with trace element standard solutions followed by drying and pressing the doped powder to compact pellets. With the quantification approach worked out and described here accurate analysis results with small uncertainties can be achieved for most elements of periodic table in almost every matrix composition. Furthermore direct traceability of the analytical results to the International System of Units (SI) is provided ensuring their higher metrological quality. Numerous additional systematic investigations concerning the preparation of the synthetic standards and their properties were carried out. The results of calibration of GD-MS instruments with synthetic standards for Co (Co-C), Cu, In, Fe and Zn matrices were checked by measuring CRMs. These results were also contrasted with those of other quantification approaches, as usually used in GD-MS routine. The results achieved with synthetic standards had the highest accuracy. The successful participation in the round robin test CCQM-P107 between international

  18. How discriminating are discriminative instruments?

    Science.gov (United States)

    Hankins, Matthew

    2008-05-27

    The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL). The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness), but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta) is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  19. How discriminating are discriminative instruments?

    Directory of Open Access Journals (Sweden)

    Hankins Matthew

    2008-05-01

    Full Text Available Abstract The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL. The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness, but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  20. Comparing Binaural Pre-processing Strategies I: Instrumental Evaluation.

    Science.gov (United States)

    Baumgärtel, Regina M; Krawczyk-Becker, Martin; Marquardt, Daniel; Völker, Christoph; Hu, Hongmei; Herzke, Tobias; Coleman, Graham; Adiloğlu, Kamil; Ernst, Stephan M A; Gerkmann, Timo; Doclo, Simon; Kollmeier, Birger; Hohmann, Volker; Dietz, Mathias

    2015-12-30

    In a collaborative research project, several monaural and binaural noise reduction algorithms have been comprehensively evaluated. In this article, eight selected noise reduction algorithms were assessed using instrumental measures, with a focus on the instrumental evaluation of speech intelligibility. Four distinct, reverberant scenarios were created to reflect everyday listening situations: a stationary speech-shaped noise, a multitalker babble noise, a single interfering talker, and a realistic cafeteria noise. Three instrumental measures were employed to assess predicted speech intelligibility and predicted sound quality: the intelligibility-weighted signal-to-noise ratio, the short-time objective intelligibility measure, and the perceptual evaluation of speech quality. The results show substantial improvements in predicted speech intelligibility as well as sound quality for the proposed algorithms. The evaluated coherence-based noise reduction algorithm was able to provide improvements in predicted audio signal quality. For the tested single-channel noise reduction algorithm, improvements in intelligibility-weighted signal-to-noise ratio were observed in all but the nonstationary cafeteria ambient noise scenario. Binaural minimum variance distortionless response beamforming algorithms performed particularly well in all noise scenarios. © The Author(s) 2015.

  1. LC-MS-BASED METABOLOMICS OF XENOBIOTIC-INDUCED TOXICITIES

    Directory of Open Access Journals (Sweden)

    Chi Chen

    2013-01-01

    Full Text Available Xenobiotic exposure, especially high-dose or repeated exposure of xenobiotics, can elicit detrimental effects on biological systems through diverse mechanisms. Changes in metabolic systems, including formation of reactive metabolites and disruption of endogenous metabolism, are not only the common consequences of toxic xenobiotic exposure, but in many cases are the major causes behind development of xenobiotic-induced toxicities (XIT. Therefore, examining the metabolic events associated with XIT generates mechanistic insights into the initiation and progression of XIT, and provides guidance for prevention and treatment. Traditional bioanalytical platforms that target only a few suspected metabolites are capable of validating the expected outcomes of xenobiotic exposure. However, these approaches lack the capacity to define global changes and to identify unexpected events in the metabolic system. Recent developments in high-throughput metabolomics have dramatically expanded the scope and potential of metabolite analysis. Among all analytical techniques adopted for metabolomics, liquid chromatography-mass spectrometry (LC-MS has been most widely used for metabolomic investigations of XIT due to its versatility and sensitivity in metabolite analysis. In this review, technical platform of LC-MS-based metabolomics, including experimental model, sample preparation, instrumentation, and data analysis, are discussed. Applications of LC-MS-based metabolomics in exploratory and hypothesis-driven investigations of XIT are illustrated by case studies of xenobiotic metabolism and endogenous metabolism associated with xenobiotic exposure.

  2. DLVO and XDLVO calculations for bacteriophage MS2 adhesion to iron oxide particles.

    Science.gov (United States)

    Park, Jeong-Ann; Kim, Song-Bae

    2015-10-01

    In this study, batch experiments were performed to examine the adhesion of bacteriophage MS2 to three iron oxide particles (IOP1, IOP2 and IOP3) with different particle properties. The characteristics of MS2 and iron oxides were analyzed using various techniques to construct the classical DLVO and XDLVO potential energy profiles between MS2 and iron oxides. X-ray diffractometry peaks indicated that IOP1 was mainly composed of maghemite (γ-Fe2O3), but also contained some goethite (α-FeOOH). IOP2 was composed of hematite (α-Fe2O3) and IOP3 was composed of iron (Fe), magnetite (Fe3O4) and iron oxide (FeO). Transmission electron microscope images showed that the primary particle size of IOP1 (γ-Fe2O3) was 12.3±4.1nm. IOP2 and IOP3 had primary particle sizes of 167±35nm and 484±192nm, respectively. A surface angle analyzer demonstrated that water contact angles of IOP1, IOP2, IOP3 and MS2 were 44.83, 64.00, 34.33 and 33.00°, respectively. A vibrating sample magnetometer showed that the magnetic saturations of IOP1, IOP2 and IOP3 were 176.87, 17.02 and 946.85kA/m, respectively. Surface potentials measured in artificial ground water (AGW; 0.075mM CaCl2, 0.082mM MgCl2, 0.051mM KCl, and 1.5mM NaHCO3; pH7.6) indicated that iron oxides and MS2 were negatively charged in AGW (IOP1=-0.0185V; IOP2=-0.0194V; IOP3=-0.0301V; MS2=-0.0245V). Batch experiments demonstrated that MS2 adhesion to iron oxides was favorable in the order of IOP1>IOP2>IOP3. This tendency was well predicted by the classical DLVO model. In the DLVO calculations, both the sphere-plate and sphere-sphere geometries predicted the same trend of MS2 adhesion to iron oxides. Additionally, noticeable differences were not found between the DLVO and XDLVO interaction energy profiles, indicating that hydrophobic interactions did not play a major role; electrostatic interactions, however, did influence MS2 adhesion to iron oxides. Furthermore, the aggregation of iron oxides was investigated with a modified XDLVO

  3. ICP-MS Technology and Its Application to Study of Environmental Radioactivity

    International Nuclear Information System (INIS)

    Syarbaini

    2000-01-01

    Study on the behaviour of artificial radionuclides in environment can be performed by investigation of fallout radionuclides that were distributed in ecosystem components. Fall out radionuclides are artificial radionuclides distributed by the nuclear weapon test explosions at atmosphere in several ten years ago. The concentration of these radionuclides in ecosystem components are very low. For the measurement of their concentrations in environmental samples by conventional radiometric methods need a large samples, complicated chemical separation and long counting time. Application of ICP-MS is good alternative to solve this problem. ICP-MS (Inductively Coupled Plasma Mass Spectrometry) is multi elements analysis instrument that wide used in the field of analytical chemistry. It can determine elements at a concentration level of pg/ml in several minutes per sample without a long chemical separation and preconcentration process. (author)

  4. Cannabinoids determination in oral fluid by SPME-GC/MS and UHPLC-MS/MS and its application on suspected drivers.

    Science.gov (United States)

    Anzillotti, Luca; Castrignanò, Erika; Strano Rossi, Sabina; Chiarotti, Marcello

    2014-12-01

    The confirmation of Δ9-tetrahydrocannabinol (THC) in oral fluid (OF) is an important issue for assessing Driving Under the Influence of Drugs (DUID). The aim of this research was to develop a highly sensitive method with minimal sample pre-treatment suitable for the analysis of small OF volumes (100 μL) for the confirmation of cannabinoids in DUID cases. Two methods were compared for the confirmation of THC in residual OF samples, obtained from a preliminary on-site screening with commercial devices. An ultra high performance LC-MS (UHPLC-MS/MS) method and an SPME-GC/MS method were hence developed. 100 μL of the residual mixture OF/preservative buffer or neat OF was simply added to 10 μL of THC-D3 (1 μg/mL) and submitted to the two different analyses: A - direct injection of 10 μL in UHPLC-MS/MS in positive electrospray ionisation (ESI) mode and B - sampling for 30 min with SPME (100 μm polydimethylsiloxane or PDMS fibre) and direct injection by desorption of the fibre in the GC injection port. The lowest limit of detection (LLOD) of THC was 2 ng/mL in UHPLC-MS/MS and 0.5 ng/mL in SPME-GC/MS. In addition, cannabidiol (CBD) and cannabinol (CBN) could be detected in GC/MS equipment at 2 ng/mL, whilst in UHPLC-MS/MS the LLOD was 20 ng/mL. Both methods were applied to 70 samples coming from roadside tests. By SPME-GC/MS analysis, THC was confirmed in 42 samples, whilst CBD was detected in 21 of them, along with CBN in 14 samples. THC concentrations ranged from traces below the lowest limit of quantification or LLOQ (2 ng/mL) up to 690 ng/mL. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  5. Analytical Method Details (MS): SE52_MS01 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available stem and Waters Q-Tof Premier UPLC-QTOF-MS ESI Negative The eluates (3 μl) were subsequently subjected to metabolome...DS column (LC-ESI-Q-Tof/MS, HPLC: Waters Acquity UPLC system; MS: Waters Q-Tof Premier). The metabolome...d (Matsuda et al., 2009c, 2010a). Briefly, the metabolome data were obtained in the negative ion mode (m/z 1... the complex nature of the metabolome data. To construct MS2T libraries, the extracts of five ecotypes were

  6. MS+MS/MS

    Indian Academy of Sciences (India)

    2014-04-12

    /Pos. 130/F5. Instr./Gel Origin. AK139/T056. Process Status Analysis Succeeded. Plate [#] Name. [1] T056P10. Instrument Sample Name. Spectra. 9. Rank. Protein Name. Accession No. Protein. Protein MW Protein. Pep.

  7. Information-dependent acquisition-mediated LC-MS/MS screening procedure with semiquantitative potential.

    Science.gov (United States)

    Decaestecker, Tineke N; Vande Casteele, Sofie R; Wallemacq, Pierre E; Van Peteghem, Carlos H; Defore, Dieter L; Van Bocxlaer, Jan F

    2004-11-01

    The development of a LC-MS/MS general unknown screening procedure for toxicologically relevant substances in blood samples by means of information-dependent acquisition on a Q-TOF is reported. IDA is an artificial intelligence-based product ion scan mode providing automatic "on-the-fly" MS to MS/MS switching. By performing information-dependent scanning at two different fragmentation energies, two collision-induced dissociation product ion spectra for each of the detected compounds are generated. As such, information-rich MS/MS spectra are obtained from precursor ions not known beforehand. In addition, limitation of the MS/MS acquisition time to an acceptable minimum resulted in an almost instantaneous switch back to the MS mode. As such, this approach provided MS chromatograms that still could be of use for semiquantitative purposes. Since the switching intensity threshold, unequivocally related to the background noise, proved a critical parameter, the solid-phase extraction procedure, the liquid chromatographic conditions, and the mass spectrometric parameters all were optimized to the advantage of information-dependent acquisition. Finally, the screening procedure we developed was benchmarked, on one hand, qualitatively against the results obtained from traditional GUS approaches in a number of routine toxicological laboratories (20 samples) and, on the other hand, quantitatively with respect to its potential against established LC-MS/MS methods (7 samples). The procedure performed very well from a qualitative point of view; almost all of the drugs detected by the conventional techniques were identified, as well as additional drugs that were not previously reported. The procedure proved well-suited for an initial semiquantitative assessment, as is customary in, for example, forensic toxicology before accurate intoxication levels are determined using targeted analytical analyses.

  8. Development of a LC-MS/MS Method for the Multi-Mycotoxin Determination in Composite Cereal-Based Samples

    Directory of Open Access Journals (Sweden)

    Barbara De Santis

    2017-05-01

    Full Text Available The analytical scenario for determining contaminants in the food and feed sector is constantly prompted by the progress and improvement of knowledge and expertise of researchers and by the technical innovation of the instrumentation available. Mycotoxins are agricultural contaminants of fungal origin occurring at all latitudes worldwide and being characterized by acute and chronic effects on human health and animal wellness, depending on the species sensitivity. The major mycotoxins of food concern are aflatoxin B1 and ochratoxin A, the first for its toxicity, and the second for its recurrent occurrence. However, the European legislation sets maximum limits for mycotoxins, such as aflatoxin B1, ochratoxin A, deoxynivalenol, fumonisins, and zearalenone, and indicative limits for T-2 and HT-2 toxins. Due to the actual probability that co-occurring mycotoxins are present in a food or feed product, nowadays, the availability of reliable, sensitive, and versatile multi-mycotoxin methods is assuming a relevant importance. Due to the wide range of matrices susceptible to mycotoxin contamination and the possible co-occurrence, a multi-mycotoxin and multi-matrix method was validated in liquid chromatography-tandem mass spectrometry (LC-MS/MS with the purpose to overcome specific matrix effects and analyze complex cereal-based samples within the Italian Total Diet Study project.

  9. Simulation of a suite of generic long-pulse neutron instruments to optimize the time structure of the European Spallation Source.

    Science.gov (United States)

    Lefmann, Kim; Klenø, Kaspar H; Birk, Jonas Okkels; Hansen, Britt R; Holm, Sonja L; Knudsen, Erik; Lieutenant, Klaus; von Moos, Lars; Sales, Morten; Willendrup, Peter K; Andersen, Ken H

    2013-05-01

    We here describe the result of simulations of 15 generic neutron instruments for the long-pulsed European Spallation Source. All instruments have been simulated for 20 different settings of the source time structure, corresponding to pulse lengths between 1 ms and 2 ms; and repetition frequencies between 10 Hz and 25 Hz. The relative change in performance with time structure is given for each instrument, and an unweighted average is calculated. The performance of the instrument suite is proportional to (a) the peak flux and (b) the duty cycle to a power of approximately 0.3. This information is an important input to determining the best accelerator parameters. In addition, we find that in our simple guide systems, most neutrons reaching the sample originate from the central 3-5 cm of the moderator. This result can be used as an input in later optimization of the moderator design. We discuss the relevance and validity of defining a single figure-of-merit for a full facility and compare with evaluations of the individual instrument classes.

  10. Simulation of a suite of generic long-pulse neutron instruments to optimize the time structure of the European Spallation Source

    Energy Technology Data Exchange (ETDEWEB)

    Lefmann, Kim; Kleno, Kaspar H.; Holm, Sonja L.; Sales, Morten [Nanoscience and eScience Centers, Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, 2100 Copenhagen O (Denmark); Danish Workpackage for the ESS Design Update Phase, Universitetsparken 5, 2100 Copenhagen O (Denmark); Birk, Jonas Okkels [Nanoscience and eScience Centers, Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, 2100 Copenhagen O (Denmark); Danish Workpackage for the ESS Design Update Phase, Universitetsparken 5, 2100 Copenhagen O (Denmark); Laboratory for Quantum Magnetism, Ecole Polytecnique Federale de Lausanne (EPFL), 1015 Lausanne (Switzerland); Hansen, Britt R.; Knudsen, Erik; Willendrup, Peter K. [Institute of Physics, Technical University of Denmark, 2800 Lyngby (Denmark); Danish Workpackage for the ESS Design Update Phase, 2800 Lyngby (Denmark); Lieutenant, Klaus [Institute for Energy Technology, Instituttveien 18, 2007 Kjeller (Norway); Helmholtz Center for Energy and Materials, Hahn-Meitner Platz, 14109 Berlin (Germany); German Work Package for the ESS Design Update, Hahn-Meitner Platz, 14109 Berlin (Germany); Moos, Lars von [Department of Energy Conversion and Storage, Technical University of Denmark, 4000 Roskilde (Denmark); Danish Workpackage for the ESS Design Update Phase, 2800 Lyngby (Denmark); Institute for Energy Conversion, Technical University of Denmark, 4000 Roskilde (Denmark); Andersen, Ken H. [European Spallation Source ESS AB, 22100 Lund (Sweden)

    2013-05-15

    We here describe the result of simulations of 15 generic neutron instruments for the long-pulsed European Spallation Source. All instruments have been simulated for 20 different settings of the source time structure, corresponding to pulse lengths between 1 ms and 2 ms; and repetition frequencies between 10 Hz and 25 Hz. The relative change in performance with time structure is given for each instrument, and an unweighted average is calculated. The performance of the instrument suite is proportional to (a) the peak flux and (b) the duty cycle to a power of approximately 0.3. This information is an important input to determining the best accelerator parameters. In addition, we find that in our simple guide systems, most neutrons reaching the sample originate from the central 3-5 cm of the moderator. This result can be used as an input in later optimization of the moderator design. We discuss the relevance and validity of defining a single figure-of-merit for a full facility and compare with evaluations of the individual instrument classes.

  11. Simulation of a suite of generic long-pulse neutron instruments to optimize the time structure of the European Spallation Source

    International Nuclear Information System (INIS)

    Lefmann, Kim; Klenø, Kaspar H.; Holm, Sonja L.; Sales, Morten; Birk, Jonas Okkels; Hansen, Britt R.; Knudsen, Erik; Willendrup, Peter K.; Lieutenant, Klaus; Moos, Lars von; Andersen, Ken H.

    2013-01-01

    We here describe the result of simulations of 15 generic neutron instruments for the long-pulsed European Spallation Source. All instruments have been simulated for 20 different settings of the source time structure, corresponding to pulse lengths between 1 ms and 2 ms; and repetition frequencies between 10 Hz and 25 Hz. The relative change in performance with time structure is given for each instrument, and an unweighted average is calculated. The performance of the instrument suite is proportional to (a) the peak flux and (b) the duty cycle to a power of approximately 0.3. This information is an important input to determining the best accelerator parameters. In addition, we find that in our simple guide systems, most neutrons reaching the sample originate from the central 3–5 cm of the moderator. This result can be used as an input in later optimization of the moderator design. We discuss the relevance and validity of defining a single figure-of-merit for a full facility and compare with evaluations of the individual instrument classes.

  12. Molecular analysis of intact preen waxes of Calidris Canutus (Aves: Scolopacidae) by GC/MS and GC/MS/MS

    NARCIS (Netherlands)

    Sinninghe Damsté, J.S.; Dekker, M.H.A.; Piersma, T.

    2000-01-01

    The intact preen wax esters of the red knot Calidris canutus were studied with gas chromatography/mass spectrometry (GC/MS) and GC/MS/MS. In this latter technique, transitions from the molecular ion to fragment ions representing the fatty acid moiety of the wax esters were measured, providing

  13. Disinfection of bacteriophage MS2 by copper in water.

    Science.gov (United States)

    Armstrong, Andrew M; Sobsey, Mark D; Casanova, Lisa M

    2017-09-01

    Households that lack piped water supply are often forced to meet water needs by storing in the home, leaving water vulnerable to contamination by viruses. Storage in copper containers can potentially prevent this type of contamination, but the inactivation kinetics of viruses by copper need to be described to make appropriate storage recommendations. This work characterized inactivation kinetics of bacteriophage MS2 as a surrogate for enteric viruses by dissolved ionic copper in water. Reduction of MS2 increased with increasing doses of copper. At 0.3 mg/L, there was a 1.8-log 10 reduction of MS2 within 6 h. At 1 and 3 mg/L, 2-2.5 log 10 inactivation could be achieved between 6 and 24 h. Parameters for the Chick-Watson, Hom, and One Hit-Two Population models of inactivation were calculated and evaluated, all of which demonstrated strong goodness-of-fit and predictability at various contact times. Copper inactivates MS2 under controlled conditions at doses between 0.3 and 3 mg/L. Although requiring longer contact times than conventional disinfectants, it is a candidate for improving the safety of stored drinking water.

  14. Analysis of perchlorate in foods and beverages by ion chromatography coupled with tandem mass spectrometry (IC-ESI-MS/MS)

    Energy Technology Data Exchange (ETDEWEB)

    El Aribi, Houssain [Applied Biosystems/MDS Sciex, 71 Four Valley Drive, Concord, Ont., L4K 4V8 (Canada)]. E-mail: houssain.aribi@sciex.com; Le Blanc, Yves J.C. [Applied Biosystems/MDS Sciex, 71 Four Valley Drive, Concord, Ont., L4K 4V8 (Canada); Antonsen, Stephen [Dionex Canada Ltd., 1540 Cornwall Road, Oakville, Ont., L6J 7W5 (Canada); Sakuma, Takeo [Applied Biosystems/MDS Sciex, 71 Four Valley Drive, Concord, Ont., L4K 4V8 (Canada)

    2006-05-10

    A new IC-ESI-MS/MS method, with simple sample preparation procedure, has been developed for quantification and confirmation of perchlorate (ClO{sub 4} {sup -}) anions in water, fresh and canned food, wine and beer samples at low part-per-trillion (ng l{sup -1}) levels. To the best of our knowledge, this is the first time an analytical method is used for determination of perchlorate in wine and beer samples. The IC-ESI-MS/MS instrumentation consisted of an ICS-2500 ion chromatography (IC) system coupled to either an API 2000{sup TM} or an API 3200{sup TM} mass spectrometer. The IC-ESI-MS/MS system was optimized to monitor two pairs of precursor and fragment ion transitions, i.e., multiple reaction monitoring (MRM). All samples had oxygen-18 isotope labeled perchlorate internal standard (ISTD) added prior to extraction. Chlorine isotope ratio ({sup 35}Cl/{sup 37}Cl) was used as a confirmation tool. The transition of {sup 35}Cl{sup 16}O{sub 4} {sup -} (m/z 98.9) into {sup 35}Cl{sup 16}O{sub 3} {sup -} (m/z 82.9) was monitored for quantifying the main analyte; the transition of {sup 37}Cl{sup 16}O{sub 4} {sup -} (m/z 100.9) into {sup 37}Cl{sup 16}O{sub 3} {sup -} (m/z 84.9) was monitored for examining a proper isotopic abundance ratio of {sup 35}Cl/{sup 37}Cl; and the transition of {sup 35}Cl{sup 18}O{sub 4} {sup -} (m/z 107.0) into {sup 35}Cl{sup 18}O{sub 3} {sup -} (m/z 89.0) was monitored for quantifying the internal standard. The minimum detection limit (MDL) for this method in de-ionized water is 5 ng l{sup -1} (ppt) using the API 2000{sup TM} mass spectrometer and 0.5 ng l{sup -1} using the API 3200{sup TM} mass spectrometer. Over 350 food and beverage samples were analyzed mostly in triplicate. Except for four, all samples were found to contain measurable amounts of perchlorate. The levels found ranged from 5 ng l{sup -1} to 463.5 {+-} 6.36 {mu}g kg{sup -1} using MRM 98.9 {sup {yields}} 82.9 and 100 {mu}l injection.

  15. Characteristic fingerprinting based on macamides for discrimination of maca (Lepidium meyenii) by LC/MS/MS and multivariate statistical analysis.

    Science.gov (United States)

    Pan, Yu; Zhang, Ji; Li, Hong; Wang, Yuan-Zhong; Li, Wan-Yi

    2016-10-01

    Macamides with a benzylalkylamide nucleus are characteristic and major bioactive compounds in the functional food maca (Lepidium meyenii Walp). The aim of this study was to explore variations in macamide content among maca from China and Peru. Twenty-seven batches of maca hypocotyls with different phenotypes, sampled from different geographical origins, were extracted and profiled by liquid chromatography with ultraviolet detection/tandem mass spectrometry (LC-UV/MS/MS). Twelve macamides were identified by MS operated in multiple scanning modes. Similarity analysis showed that maca samples differed significantly in their macamide fingerprinting. Partial least squares discriminant analysis (PLS-DA) was used to differentiate samples according to their geographical origin and to identify the most relevant variables in the classification model. The prediction accuracy for raw maca was 91% and five macamides were selected and considered as chemical markers for sample classification. When combined with a PLS-DA model, characteristic fingerprinting based on macamides could be recommended for labelling for the authentication of maca from different geographical origins. The results provided potential evidence for the relationships between environmental or other factors and distribution of macamides. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  16. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Definition of MS Myelin Immune-Mediated Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters ... d Research News & Progress Research News MSPARIS2017 Stem Cells in MS Progressive MS Research Clinical Trials in ...

  17. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... MS Relapsing-remitting MS (RRMS) Share this page Facebook Twitter Email Relapsing-remitting MS (RRMS) Relapsing-remitting ... Here Start Here Colophon Stay Informed Join Us Facebook Twitter LinkedIn YouTube Pinterest MS Connection About the ...

  18. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... d Living Well with MS d Diet, Exercise & Healthy Behaviors Diet & Nutrition Exercise Heat & Temperature Sensitivity Sleep Vaccinations Women's Health Unhealthy Habits Managing MS and Another Condition Aging with MS Anesthesia and Surgery Managing Your MS ...

  19. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... to navigation Skip to content Menu Navigation National Multiple Sclerosis Society Sign In In Your Area Donate Donate ... of MS What Causes MS? Who Gets MS? Multiple Sclerosis FAQs Types of MS Related Conditions Symptoms & Diagnosis ...

  20. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Relapsing-remitting MS (RRMS) Share this page Facebook Twitter Email Relapsing-remitting MS (RRMS) Relapsing-remitting MS ( ... Start Here Colophon Stay Informed Join Us Facebook Twitter LinkedIn YouTube Pinterest MS Connection About the Society ...

  1. Brain atrophy and lesion load predict long term disability in multiple sclerosis

    DEFF Research Database (Denmark)

    Popescu, Veronica; Agosta, Federica; Hulst, Hanneke E

    2013-01-01

    To determine whether brain atrophy and lesion volumes predict subsequent 10 year clinical evolution in multiple sclerosis (MS).......To determine whether brain atrophy and lesion volumes predict subsequent 10 year clinical evolution in multiple sclerosis (MS)....

  2. Digital Education Governance: Data Visualization, Predictive Analytics, and "Real-Time" Policy Instruments

    Science.gov (United States)

    Williamson, Ben

    2016-01-01

    Educational institutions and governing practices are increasingly augmented with digital database technologies that function as new kinds of policy instruments. This article surveys and maps the landscape of digital policy instrumentation in education and provides two detailed case studies of new digital data systems. The Learning Curve is a…

  3. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... the Challenges of MS You CAN! Webcasts DVDs Books For Kids: Keep S'myelin Información en Español Brochures ... Managing MS and Another Condition Aging with MS Anesthesia and Surgery Managing Your MS d Emotional Well- ...

  4. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... the Challenges of MS You CAN! Webcasts DVDs Books For Kids: Keep S'myelin Información en Español Brochures ... MS Managing MS Resources for You and Your Practice Publications for Clinicians Publications for Your Patients MS ...

  5. Molecular Mapping of D1, D2 and ms5 Revealed Linkage between the Cotyledon Color Locus D2 and the Male-Sterile Locus ms5 in Soybean

    Directory of Open Access Journals (Sweden)

    Alina Ott

    2013-07-01

    Full Text Available In soybean, genic male sterility can be utilized as a tool to develop hybrid seed. Several male-sterile, female-fertile mutants have been identified in soybean. The male-sterile, female-fertile ms5 mutant was selected after fast neutron irradiation. Male-sterility due to ms5 was associated with the “stay-green” cotyledon color mutation. The cotyledon color trait in soybean is controlled by two loci, D1 and D2. Association between cotyledon color and male-sterility can be instrumental in early phenotypic selection of sterility for hybrid seed production. The use of such selection methods saves time, money, and space, as fewer seeds need to be planted and screened for sterility. The objectives of this study were to compare anther development between male-fertile and male-sterile plants, to investigate the possible linkages among the Ms5, D1 and D2 loci, and to determine if any of the d1 or d2 mutations can be applied in hybrid seed production. The cytological analysis during anther development displayed optically clear, disintegrating microspores and enlarged, engorged pollen in the male-sterile, female-fertile ms5ms5 plants, a common characteristic of male-sterile mutants. The D1 locus was mapped to molecular linkage group (MLG D1a and was flanked by Satt408 and BARCSOYSSR_01_1622. The ms5 and D2 loci were mapped to MLG B1 with a genetic distance ~12.8 cM between them. These results suggest that use of the d2 mutant in the selection of male-sterile line may attenuate the cost hybrid seed production in soybean.

  6. A comparative study of sample dissolution techniques and plasma-based instruments for the precise and accurate quantification of REEs in mineral matrices

    International Nuclear Information System (INIS)

    Whitty-Léveillé, Laurence; Turgeon, Keven; Bazin, Claude; Larivière, Dominic

    2017-01-01

    The recent commercialisation of inductively coupled plasma tandem mass spectrometric (ICP-MS/MS) instruments has provided analytical chemists with a new tool to properly quantify atomic composition in a variety of matrices with minimal sample preparation. In this article, we report on our assessment of the compatibility of 3 sample preparation techniques (open-vessel acid digestion, microwave digestion and alkaline fusion) for the quantification of rare earth elements (REEs) in mineral matrices. The combination of the high digestion temperatures (1050 °C) and using LiBO_2 as a flux was the most effective strategy for the digestion of all rare earth elements in mineral matrices and was compatible with ICP-MS/MS measurements. We also assessed the analytical performances of ICP-MS/MS against other plasma-based instrumentation (microwave induced plasma and inductively coupled plasma atomic emission spectroscopy (MIP-AES and ICP-AES, respectively) and single quadrupole inductively coupled plasma mass spectrometry (ICP-MS). The comparative study showed that the concentrations obtained by ICP-MS/MS are in excellent agreement with the certified reference material values, and much more suited than the other analytical techniques tested for the quantification of REEs, which exhibited low detectability and/or spectral interferences for some elements/isotopes. Finally, the ruggedness of the analytical protocol proposed which combines a rapid sample dissolution step performed by an automated fusion unit and an ICP-MS/MS as a detector was established using various certified mineral matrices containing variable levels of REEs. - Highlights: • Three types of digestion methods were tested. • Four types of analytical techniques were compared. • Elimination of the spectral interferences encountered in ICP-MS was achieved by the use of Tandem ICP-MS. • Robustness of the analytical procedure was successfully evaluate on four types of certified reference material.

  7. A comparative study of sample dissolution techniques and plasma-based instruments for the precise and accurate quantification of REEs in mineral matrices

    Energy Technology Data Exchange (ETDEWEB)

    Whitty-Léveillé, Laurence; Turgeon, Keven [Département de génie des mines, de la métallurgie et des matériaux, Université Laval, Québec, QC (Canada); Département de chimie, Université Laval, Québec, QC (Canada); Bazin, Claude [Département de génie des mines, de la métallurgie et des matériaux, Université Laval, Québec, QC (Canada); Larivière, Dominic, E-mail: dominic.lariviere@chm.ulaval.ca [Département de chimie, Université Laval, Québec, QC (Canada)

    2017-04-08

    The recent commercialisation of inductively coupled plasma tandem mass spectrometric (ICP-MS/MS) instruments has provided analytical chemists with a new tool to properly quantify atomic composition in a variety of matrices with minimal sample preparation. In this article, we report on our assessment of the compatibility of 3 sample preparation techniques (open-vessel acid digestion, microwave digestion and alkaline fusion) for the quantification of rare earth elements (REEs) in mineral matrices. The combination of the high digestion temperatures (1050 °C) and using LiBO{sub 2} as a flux was the most effective strategy for the digestion of all rare earth elements in mineral matrices and was compatible with ICP-MS/MS measurements. We also assessed the analytical performances of ICP-MS/MS against other plasma-based instrumentation (microwave induced plasma and inductively coupled plasma atomic emission spectroscopy (MIP-AES and ICP-AES, respectively) and single quadrupole inductively coupled plasma mass spectrometry (ICP-MS). The comparative study showed that the concentrations obtained by ICP-MS/MS are in excellent agreement with the certified reference material values, and much more suited than the other analytical techniques tested for the quantification of REEs, which exhibited low detectability and/or spectral interferences for some elements/isotopes. Finally, the ruggedness of the analytical protocol proposed which combines a rapid sample dissolution step performed by an automated fusion unit and an ICP-MS/MS as a detector was established using various certified mineral matrices containing variable levels of REEs. - Highlights: • Three types of digestion methods were tested. • Four types of analytical techniques were compared. • Elimination of the spectral interferences encountered in ICP-MS was achieved by the use of Tandem ICP-MS. • Robustness of the analytical procedure was successfully evaluate on four types of certified reference material.

  8. Ferro-based derivatizing agents for LC/MS an LC/EC/MS

    NARCIS (Netherlands)

    Seiwert, Bettina

    2007-01-01

    Within this thesis, the development and application of ferrocene-based derivatizing agents for LC/MS and LC/EC/MS is presented. The advantages of derivatization by ferrocenes are the similtaneous introduction of a mass tag and an electroactive group, which make them ideally suited for LC/MS and

  9. Forensic investigation of brick stones using instrumental neutron activation analysis (INAA), laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and X-ray fluorescence analysis (XRF)

    International Nuclear Information System (INIS)

    Scheid, Nicole; Becker, Stefan; Duecking, Marc; Hampel, Gabriele; Volker Kratz, Jens; Watzke, Peter; Weis, Peter; Zauner, Stephan

    2009-01-01

    Brick stones collected from different production facilities were studied for their elemental compositions under forensic aspects using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS), instrumental neutron activation analysis (INAA) and X-ray fluorescence analysis (XRF). The aim of these examinations was to assess the potential of these methods in forensic comparison analyses of brick stones. The accuracy of the analysis methods was evaluated using NIST standard reference materials (679, 98b and 97b). In order to compare the stones to each other, multivariate data analysis was used. The evaluation of the INAA results (based on the concentrations of V, Na, K, Sm, U, Sc, Fe, Co, Rb and Cs) using principal component analysis (PCA) and cluster analysis is presented as an example. The results derived from the different analytical methods are consistent. It was shown that elemental analysis using the described methods is a valuable tool for forensic examinations of brick stones.

  10. An assessment of communication skills of the MD/MS students of institute of medicine in Nepal

    Directory of Open Access Journals (Sweden)

    Jagdish Prasad Agrawal

    2013-09-01

    Full Text Available Introduction The main objective of this study was to assess the level of interpersonal communication skills of MD/MS resident doctors and to provide recommendations for the future. Methods Descriptive, cross sectional, qualitative and quantitative research design was used. 7- point Likert scale (0 to 6 MAAS-Global scoring instrument was used. The subjects of the research were the MD/MS residents from various departments of Maharajgunj Medical Campus (MMC of Institute of Medicine, Maharajgunj, Kathmandu. Out of 162 MD/MS residents, only 30 (18.5% MD/MS residents were selected for the sample size for the study from 1st, 2nd and 3rd year. One MD/MS resident was required four video recording to conduct four interviews with patients coming to the outpatient department. Results There was high degree of positive correlation between Information sharing and Management (r=0.746 whereas weak negative correlation on clarification and diagnosis (r=-0.011. Inter-rater correlation was established before hand and was satisfactory (p < 0.05. Conclusions This base line study of MD/MS residents shows that over all MD/MS residents are deficient in almost all the components of interpersonal communication skills. A communication skills training course in postgraduate medical education could improve the existing communication skills of the doctors in Nepal.

  11. Application of CE-ICP-MS and CE-ESI-MS/MS for identification of Zn-binding ligands in Goji berries extracts.

    Science.gov (United States)

    Ruzik, Lena; Kwiatkowski, Piotr

    2018-06-01

    The identification of groups of ligands binding metals is a crucial issue for the better understanding of their bioaccessibility. In the current study, we have intended an approach for identification of Zn-binding ligands based on using capillary electrophoresis combined with inductively coupled plasma mass spectrometry (CE-ICP-MS) and tandem electrospray ionization mass spectrometry (CE-ESI-MS/MS). The approach, which featured the use of the coupling of capillary electrophoresis with inductively coupled plasma mass spectrometry allows to separate and observe zinc ions present in complexes with respect to their size and charge and to identify nine compounds with zinc isotopic profile. CE-ICP-MS provides us with information about presence of zinc species and elemental information about zinc distribution. CE-ESI-MS/MS provide us with information about the most favorable Zn binding ligands: amino acids, flavonols, stilbenoids, fenolic acids and carotenoids. The presented work is the continuation of previous studies based on using LC-ESI-MS/MS, though, now we presented a new solutions with the possibility of changing detectors without changing the separation techniques, what is important without re-optimizing the method. The new presented method allows to identify the zinc-binding ligands in shorter time. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Analysis of pesticide residues in strawberries and soils by GC-MS/MS, LC-MS/MS and two-dimensional GC-time-of-flight MS comparing organic and integrated pest management farming.

    Science.gov (United States)

    Fernandes, Virgínia C; Lehotay, Steven J; Geis-Asteggiante, Lucía; Kwon, Hyeyoung; Mol, Hans G J; van der Kamp, Henk; Mateus, Nuno; Domingues, Valentina F; Delerue-Matos, Cristina

    2014-01-01

    This study analysed 22 strawberry and soil samples after their collection over the course of 2 years to compare the residue profiles from organic farming with integrated pest management practices in Portugal. For sample preparation, we used the citrate-buffered version of the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. We applied three different methods for analysis: (1) 27 pesticides were targeted using LC-MS/MS; (2) 143 were targeted using low pressure GC-tandem mass spectrometry (LP-GC-MS/MS); and (3) more than 600 pesticides were screened in a targeted and untargeted approach using comprehensive, two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOF-MS). Comparison was made of the analyses using the different methods for the shared samples. The results were similar, thereby providing satisfactory confirmation of both similarly positive and negative findings. No pesticides were found in the organic-farmed samples. In samples from integrated pest management practices, nine pesticides were determined and confirmed to be present, ranging from 2 µg kg(-1) for fluazifop-p-butyl to 50 µg kg(-1) for fenpropathrin. Concentrations of residues in strawberries were less than European maximum residue limits.

  13. Risk factor analysis for predicting vertebral body re-collapse after posterior instrumented fusion in thoracolumbar burst fracture.

    Science.gov (United States)

    Jang, Hae-Dong; Bang, Chungwon; Lee, Jae Chul; Soh, Jae-Wan; Choi, Sung-Woo; Cho, Hyeung-Kyu; Shin, Byung-Joon

    2018-02-01

    In the posterior instrumented fusion surgery for thoracolumbar (T-L) burst fracture, early postoperative re-collapse of well-reduced vertebral body fracture could induce critical complications such as correction loss, posttraumatic kyphosis, and metal failure, often leading to revision surgery. Furthermore, re-collapse is quite difficult to predict because of the variety of risk factors, and no widely accepted accurate prediction systems exist. Although load-sharing classification has been known to help to decide the need for additional anterior column support, this radiographic scoring system has several critical limitations. (1) To evaluate risk factors and predictors for postoperative re-collapse in T-L burst fractures. (2) Through the decision-making model, we aimed to predict re-collapse and prevent unnecessary additional anterior spinal surgery. Retrospective comparative study. Two-hundred and eight (104 men and 104 women) consecutive patients with T-L burst fracture who underwent posterior instrumented fusion were reviewed retrospectively. Burst fractures caused by high-energy trauma (fall from a height and motor vehicle accident) with a minimum 1-year follow-up were included. The average age at the time of surgery was 45.9 years (range, 15-79). With respect to the involved spinal level, 95 cases (45.6%) involved L1, 51 involved T12, 54 involved L2, and 8 involved T11. Mean fixation segments were 3.5 (range, 2-5). Pedicle screw instrumentation including fractured vertebra had been performed in 129 patients (62.3%). Clinical data using self-report measures (visual analog scale score), radiographic measurements (plain radiograph, computed tomography, and magnetic resonance image), and functional measures using the Oswestry Disability Index were evaluated. Body height loss of fractured vertebra, body wedge angle, and Cobb angle were measured in serial plain radiographs. We assigned patients to the re-collapse group if their body height loss progressed greater

  14. Quantitative Determination of Perfluorochemicals and Fluorotelomer Alcohols in Plants from Biosolid-Amended Fields using LC/MS/MS and GC/MS

    Science.gov (United States)

    Analytical methods for determining perfluorochemicals (PFCs) and fluorotelomer alcohols (FTOHs) in plants using liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) were developed, and applied to quantify a suite of analytes i...

  15. In Vivo Metabolism Study of Xiamenmycin A in Mouse Plasma by UPLC-QTOF-MS and LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Feng Lei

    2015-01-01

    Full Text Available Xiamenmycin A is an antifibrotic leading compound with a benzopyran skeleton that is isolated from mangrove-derived Streptomyces xiamenensis. As a promising small molecule for fibrotic diseases, less information is known about its metabolic characteristics in vivo. In this study, the time-course of xiamenmycin A in mouse plasma was investigated by relative quantification. After two types of administration of xiamenmycin A at a single dose of 10 mg/kg, the plasma concentrations were measured quantitatively by LC-MS/MS. The dynamic changes in the xiamenmycin A concentration showed rapid absorption and quick elimination in plasma post-administration. Four metabolites (M1–M4 were identified in blood by UPLC-QTOF-MS, and xiamenmycin B (M3 is the principal metabolite in vivo, as verified by comparison of the authentic standard sample. The structures of other metabolites were identified based on the characteristics of their MS and MS/MS data. The newly identified metabolites are useful for understanding the metabolism of xiamenmycin A in vivo, aiming at the development of an anti-fibrotic drug candidate for the therapeutic treatment of excessive fibrotic diseases.

  16. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Become an MS Activist Take Action Current Advocacy Issues Advocacy Results Advocacy News d Raise Awareness d ... MS are more likely to experience gradually worsening problems with walking and mobility, along with whatever other symptoms they may have. Diagnosing relapsing-remitting MS (RRMS) Learn More Learn More ... Room MS Prevalence ...

  17. Survey of diagnostic and treatment practices for multiple sclerosis (MS) in Europe. Part 2: Progressive MS, paediatric MS, pregnancy and general management.

    Science.gov (United States)

    Fernández, O; Delvecchio, M; Edan, G; Fredrikson, S; Giovannoni, G; Hartung, H-P; Havrdova, E; Kappos, L; Pozzilli, C; Soerensen, P S; Tackenberg, B; Vermersch, P; Comi, G

    2018-05-01

    The European Charcot Foundation supported the development of a set of surveys to understand current practice patterns for the diagnosis and management of multiple sclerosis (MS) in Europe. Part 2 of the report summarizes survey results related to secondary progressive MS (SPMS), primary progressive MS (PPMS), pregnancy, paediatric MS and overall patient management. A steering committee of MS neurologists developed case- and practice-based questions for two sequential surveys distributed to MS neurologists throughout Europe. Respondents generally favoured changing rather than stopping disease-modifying treatment (DMT) in patients transitioning from relapsing-remitting MS to SPMS, particularly with active disease. Respondents would not initiate DMT in patients with typical PPMS symptoms, although the presence of ≥1 spinal cord or brain gadolinium-enhancing lesion might affect that decision. For patients considering pregnancy, respondents were equally divided on whether to stop treatment before or after conception. Respondents strongly favoured starting DMT in paediatric MS with active disease; recommended treatments included interferon, glatiramer acetate and, in John Cunningham virus negative patients, natalizumab. Additional results regarding practice-based questions and management are summarized. Results of part 2 of the survey of diagnostic and treatment practices for MS in Europe largely mirror results for part 1, with neurologists in general agreement about the treatment and management of SPMS, PPMS, pregnancy and paediatric MS as well as the general management of MS. However, there are also many areas of disagreement, indicating the need for evidence-based recommendations and/or guidelines. © 2018 EAN.

  18. Application of neural networks for the prediction of multidirectional magnetostriction

    CERN Document Server

    Baumgartinger, N; Pfützner, H; Krismanic, G

    2000-01-01

    This paper describes attempts to use artificial neural networks (ANNs) for the prediction of magnetostriction (MS) characteristics of transformer core materials. In this first approach, the ANNs were trained with data from a rotational single-sheet tester to predict MS in rolling direction (r.d.) as a function of material grade, amplitude and shape of multidirectional magnetisation as well as the level of additional mechanical stress. It is shown that ANNs are able to forecast the corresponding relative MS changes in an approximate way.

  19. Sulphur fertilization influences the sulphur species composition in Allium sativum: sulphomics using HPLC-ICPMS/MS-ESI-MS/MS.

    Science.gov (United States)

    Raab, Andrea; Ronzan, Marilena; Feldmann, Joerg

    2017-10-18

    Garlic (A. sativum) contains a large number of small sulphur (S)-containing metabolites, which are important for its taste and smell and vary with A. sativum variety and growth conditions. This study was designed to investigate the influence of different sulphur-fertilization regimes on low molecular weight S-species by attempting the first sulphur mass balance in A. sativum roots and bulbs using HPLC-ICPMS/MS-ESI-MS/MS. Species unspecific quantification of acid soluble S-containing metabolites was achieved using HPLC-ICP-MS/MS. For identification of the compounds, high resolution ESI-MS (Orbitrap LTQ and q-TOF) was used. The plants contained up to 54 separated sulphur-containing compounds, which constitute about 80% of the total sulphur present in A. sativum. The roots and bulbs of A. sativum contained the same compounds, but not necessarily the same amounts and proportions. The S-containing metabolites in the roots reacted more sensitively to manipulations of sulphur fertilization than those compounds in the bulbs. In addition to known compounds (e.g. γ-glutamyl-S-1-propenylcysteine) we were able to identify and partially quantify 31 compounds. Three as yet undescribed S-containing compounds were also identified and quantified for the first time. Putative structures were assigned to the oxidised forms of S-1-propenylmercaptoglutathione, S-2-propenylmercaptoglutathione, S-allyl/propenyl-containing PC-2 and 2-amino-3-[(2-carboxypropyl)sulfanyl]propanoic acid. The parallel use of ICP-MS/MS as a sulphur-specific detector and ESI-MS as a molecular detector simplifies the identification and quantification of sulphur containing metabolites without species specific standards. This non-target analysis approach enables a mass balance approach and identifies the occurrence of the so far unidentified organosulphur compounds. The experiments showed that the sulphur-fertilization regime does not influence sulphur-speciation, but the concentration of some S

  20. An improved method of sample preparation on AnchorChip targets for MALDI-MS and MS/MS and its application in the liver proteome project

    DEFF Research Database (Denmark)

    Zhang, Xumin; Shi, Liang; Shu, Shaokung

    2007-01-01

    An improved method for sample preparation for MALDI-MS and MS/MS using AnchorChip targets is presented. The method, termed the SMW method (sample, matrix wash), results in better sensitivity for peptide mass fingerprinting as well as for sequencing by MS/MS than previously published methods. The ...

  1. Ionic diffusion and mass discrimination effects in the new generation of short flow tube SIFT-MS instruments

    Czech Academy of Sciences Publication Activity Database

    Smith, D.; Pysanenko, A.; Španěl, Patrik

    2009-01-01

    Roč. 281, 1-2 (2009), s. 15-23 ISSN 1387-3806 R&D Projects: GA ČR GA202/06/0776 Institutional research plan: CEZ:AV0Z40400503 Keywords : SIFT-MS * ionic diffusion * mass discrimination * trace gas analysis Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.117, year: 2009

  2. Selectivity in the sample preparation for the analysis of drug residues in products of animal origin using LC-MS

    NARCIS (Netherlands)

    Berendsen, B.J.A.; Stolker, A.A.M.; Nielen, M.W.F.

    2013-01-01

    Sample preparation is critical in relation to analysis time, sample throughput and therefore analysis costs. Due to recent advances in liquid chromatography-mass spectrometry (LC-MS) instrumentation, the detection of many compounds within one run became possible, and methods for the simultaneous

  3. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... for You and Your Practice Publications for Clinicians Publications for Your Patients MS Navigator Program Programs and Services for Your Patients ... Relapsing-remitting MS (RRMS) Relapsing-remitting MS ( ...

  4. Multi-elemental analysis of aqueous geochemical samples by quadrupole inductively coupled plasma-mass spectrometry (ICP-MS)

    Science.gov (United States)

    Wolf, Ruth E.; Adams, Monique

    2015-01-01

    Typically, quadrupole inductively coupled plasma-mass spectrometry (ICP-MS) is used to determine as many as 57 major, minor, and trace elements in aqueous geochemical samples, including natural surface water and groundwater, acid mine drainage water, and extracts or leachates from geological samples. The sample solution is aspirated into the inductively coupled plasma (ICP) which is an electrodeless discharge of ionized argon gas at a temperature of approximately 6,000 degrees Celsius. The elements in the sample solution are subsequently volatilized, atomized, and ionized by the ICP. The ions generated are then focused and introduced into a quadrupole mass filter which only allows one mass to reach the detector at a given moment in time. As the settings of the mass analyzer change, subsequent masses are allowed to impact the detector. Although the typical quadrupole ICP-MS system is a sequential scanning instrument (determining each mass separately), the scan speed of modern instruments is on the order of several thousand masses per second. Consequently, typical total sample analysis times of 2–3 minutes are readily achievable for up to 57 elements.

  5. Risk prediction in the community: A systematic review of case-finding instruments that predict adverse healthcare outcomes in community-dwelling older adults.

    LENUS (Irish Health Repository)

    O'Caoimh, Rónán

    2015-09-01

    Few case-finding instruments are available to community healthcare professionals. This review aims to identify short, valid instruments that detect older community-dwellers risk of four adverse outcomes: hospitalisation, functional-decline, institutionalisation and death. Data sources included PubMed and the Cochrane library. Data on outcome measures, patient and instrument characteristics, and trial quality (using the Quality In Prognosis Studies [QUIPS] tool), were double-extracted for derivation-validation studies in community-dwelling older adults (>50 years). Forty-six publications, representing 23 unique instruments, were included. Only five were externally validated. Mean patient age range was 64.2-84.6 years. Most instruments n=18, (78%) were derived in North America from secondary analysis of survey data. The majority n=12, (52%), measured more than one outcome with hospitalisation and the Probability of Repeated Admission score the most studied outcome and instrument respectively. All instruments incorporated multiple predictors. Activities of daily living n=16, (70%), was included most often. Accuracy varied according to instruments and outcomes; area under the curve of 0.60-0.73 for hospitalisation, 0.63-0.78 for functional decline, 0.70-0.74 for institutionalisation and 0.56-0.82 for death. The QUIPS tool showed that 5\\/23 instruments had low potential for bias across all domains. This review highlights the present need to develop short, reliable, valid instruments to case-find older adults at risk in the community.

  6. Analysis of radioactive corrosion test specimens by means of ICP-MS. Comparison with earlier methods

    International Nuclear Information System (INIS)

    Forsyth, Roy

    1997-07-01

    In June 1992, an ICP-MS instrument (Inductively Coupled Plasma-Mass Spectrometry) was commissioned for use with radioactive sample solutions at Studsvik Nuclear's Hot Cell Laboratory. For conventional environmental samples the instrument permits the simultaneous analysis of many trace elements, but the software used in evaluation of the mass spectra is based on a library of isotopic compositions relevant only for elements in the lithosphere. Fission products and actinides, however, have isotopic compositions which are significantly different from the natural elements, and which also vary with the burnup of the nuclear fuel specimen. Consequently, a spread-sheet had to be developed which could evaluate the mass spectra with these isotopic compositions. Following these preparations, a large number of samples (about 200) from SKB's experimental programme for the study of spent fuel corrosion have been analyzed by the ICP-MS technique. Many of these samples were archive solutions of samples which had been taken earlier in the programme. This report presents a comparison of the analytical results for uranium, plutonium, cesium, strontium and technetium by both the ICP-MS technique, and the previously used analytical methods. For three products, a satisfactory agreement between the results from the various methods was obtained, but for uranium and plutonium the ICP-MS method gave results which were 10-20% higher than the conventional methods. The comparison programme has also shown, not unexpectedly, that significant losses of plutonium from solution had occurred, by precipitation and/or absorption, in the archive solutions during storage. It can be expected that such losses also occur for the other actinides, and consequently, all the analytical results for actinides in older archive solutions must be treated with great caution. 9 refs

  7. Limit of detection in the presence of instrumental and non-instrumental errors: study of the possible sources of error and application to the analysis of 41 elements at trace levels by inductively coupled plasma-mass spectrometry technique

    International Nuclear Information System (INIS)

    Badocco, Denis; Lavagnini, Irma; Mondin, Andrea; Tapparo, Andrea; Pastore, Paolo

    2015-01-01

    In this paper the detection limit was estimated when signals were affected by two error contributions, namely instrumental errors and operational-non-instrumental errors. The detection limit was theoretically obtained following the hypothesis testing schema implemented with the calibration curve methodology. The experimental calibration design was based on J standards measured I times with non-instrumental errors affecting each standard systematically but randomly among the J levels. A two-component variance regression was performed to determine the calibration curve and to define the detection limit in these conditions. The detection limit values obtained from the calibration at trace levels of 41 elements by ICP-MS resulted larger than those obtainable from a one component variance regression. The role of the reagent impurities on the instrumental errors was ascertained and taken into account. Environmental pollution was studied as source of non-instrumental errors. The environmental pollution role was evaluated by Principal Component Analysis technique (PCA) applied to a series of nine calibrations performed in fourteen months. The influence of the seasonality of the environmental pollution on the detection limit was evidenced for many elements usually present in the urban air particulate. The obtained results clearly indicated the need of using the two-component variance regression approach for the calibration of all the elements usually present in the environment at significant concentration levels. - Highlights: • Limit of detection was obtained considering a two variance component regression. • Calibration data may be affected by instrumental and operational conditions errors. • Calibration model was applied to determine 41 elements at trace level by ICP-MS. • Non instrumental errors were evidenced by PCA analysis

  8. Analytical Method Details (MS): SE53_MS03 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available SE53_MS03 CE-TOF/MS Agilent CE capillary electrophoresis system,Agilent G3250AA LC/...s were performed using an Agilent CE capillary electrophoresis system (Agilent Technologies, Waldbronn, Germ

  9. Determination of 241Pu in nuclear waste slurries: a comparative study using LSC and ICP-MS.

    Science.gov (United States)

    Jäggi, M; Röllin, S; Alvarado, J A Corcho; Eikenberg, J

    2012-02-01

    (241)Pu was determined in slurry samples from a nuclear reactor decommissioning project at the Paul Scherrer Institute (Switzerland). To validate the results, the (241)Pu activities of five samples were determined by LSC (TriCarb and Quantulus) and ICP-MS, with each instrument at a different laboratory. In lack of certified reference materials for (241)Pu, the methods were further validated using the (241)Pu information values of two reference sediments (IAEA-300 and IAEA-384). Excellent agreement with the results was found between LSC and ICP-MS in the nuclear waste slurries and the reference sediments. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Quality evaluation of LC-MS/MS-based E. coli H antigen typing (MS-H) through label-free quantitative data analysis in a clinical sample setup.

    Science.gov (United States)

    Cheng, Keding; Sloan, Angela; McCorrister, Stuart; Peterson, Lorea; Chui, Huixia; Drebot, Mike; Nadon, Celine; Knox, J David; Wang, Gehua

    2014-12-01

    The need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS-H, a method originally developed for rapid H antigen typing of E. coli using LC-MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation. Motile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC-MS/MS batch run procedures and MS-H typing rules were compared and summarized through quantitative analysis of MS-H data output for a standard method development. Label-free quantitative data analysis of MS-H typing was proven very useful for examining the quality of MS-H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS-H typing was established and validated. With LC-MS/MS batch run procedure and database search parameter unique for E. coli MS-H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. A comparison of GC-FID and PTR-MS toluene measurements in ambient air under conditions of enhanced monoterpene loading

    Directory of Open Access Journals (Sweden)

    J. L. Ambrose

    2010-07-01

    Full Text Available Toluene was measured using both a gas chromatographic system (GC, with a flame ionization detector (FID, and a proton transfer reaction-mass spectrometer (PTR-MS at the AIRMAP atmospheric monitoring station Thompson Farm (THF in rural Durham, NH during the summer of 2004. Simultaneous measurements of monoterpenes, including α- and β-pinene, camphene, Δ 3-carene, and d-limonene, by GC-FID demonstrated large enhancements in monoterpene mixing ratios relative to toluene, with median and maximum enhancement ratios of ~2 and ~30, respectively. A detailed comparison between the GC-FID and PTR-MS toluene measurements was conducted to test the specificity of PTR-MS for atmospheric toluene measurements under conditions often dominated by biogenic emissions. We derived quantitative estimates of potential interferences in the PTR-MS toluene measurements related to sampling and analysis of monoterpenes, including fragmentation of the monoterpenes and some of their primary carbonyl oxidation products via reactions with H3O+, O2+ and NO+ in the PTR-MS drift tube. The PTR-MS and GC-FID toluene measurements were in good quantitative agreement and the two systems tracked one another well from the instrumental limits of detection to maximum mixing ratios of ~0.5 ppbv. A correlation plot of the PTR-MS versus GC-FID toluene measurements was described by the least squares regression equation y=(1.13± 0.02x−(0.008±0.003 ppbv, suggesting a small ~13% positive bias in the PTR-MS measurements. The bias corresponded with a ~0.055 ppbv difference at the highest measured toluene level. The two systems agreed quantitatively within the combined 1σ measurement precisions for 60% of the measurements. Discrepancies in the measured mixing ratios were not well correlated with enhancements in the monoterpenes. Better quantitative agreement between the two systems was obtained by

  12. Multi-Segment Direct Inject nano-ESI-LTQ-FT-ICR-MS/MS For Protein Identification

    Directory of Open Access Journals (Sweden)

    Neal Rachel E

    2011-07-01

    Full Text Available Abstract Reversed phase high performance liquid chromatography (HPLC interfaced to electrospray tandem mass spectrometry (MS/MS is commonly used for the identification of peptides from proteolytically cleaved proteins embedded in a polyacrylamide gel matrix as well as for metabolomics screening. HPLC separations are time consuming (30-60 min average, costly (columns and mobile phase reagents, and carry the risk of column carry over between samples. The use of a chip-based nano-ESI platform (Advion NanoMate based on replaceable nano-tips for sample introduction eliminates sample cross-contamination, provides unchanging sample matrix, and enhances spray stability with attendant increases in reproducibility. Recent papers have established direct infusion nano-ESI-MS/MS utilizing the NanoMate for protein identification of gel spots based on full range MS scans with data dependent MS/MS. In a full range scan, discontinuous ion suppression due to sample matrix can impair identification of putative mass features of interest in both the proteomic and metabolomic workflows. In the current study, an extension of an established direct inject nano-ESI-MS/MS method is described that utilizes the mass filtering capability of an ion-trap for ion packet separation into four narrow mass ranges (50 amu overlap with segment specific dynamic data dependent peak inclusion for MS/MS fragmentation (total acquisition time of 3 minutes. Comparison of this method with a more traditional nanoLC-MS/MS based protocol utilizing solvent/sample stream splitting to achieve nanoflow demonstrated comparable results for protein identification from polyacrylamide gel matrices. The advantages of this method include full automation, lack of cross-contamination, low cost, and high throughput.

  13. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS ... times as often as men; in PPMS, the number of women and men are approximately equal. RRMS ...

  14. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Living Well with MS Diet, Exercise & Healthy Behaviors Emotional Well-Being Spiritual Well-Being Cognitive Health Work, ... MS Anesthesia and Surgery Managing Your MS d Emotional Well-Being Mood Changes d Spiritual Well-Being ...

  15. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS ... of Distinction Lawry Circle Circle of Influence d Planned Giving d Other Ways to Give Donate by ...

  16. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Trials in MS Wellness and Lifestyle Research Diet Vitamin D How and Why Do Scientists Share Results ... The National MS Society is Here to Help Need More Information? We Are Here Our MS Navigators ...

  17. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS ... Community at MSconnection.org Join a Local Support Group Peer Connections: One-on-One Edward M. Dowd ...

  18. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS ... Review of Society's Research Programs d Careers d Leadership Board of Directors Senior Leadership Team Founder Sylvia ...

  19. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... working effectively. How does RRMS differ from progressive types of MS? While RRMS is defined by attacks ... Pinterest MS Connection About the Society Vision Careers Leadership Cultural Values Financials News Press Room MS Prevalence ...

  20. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Room Events at a Glance MS the Disease Public Service Announcements In the News Archives d MS ... For Professionals Researchers Physicians Nurses Rehabilitation Professionals Mental Health Professionals Health and Wellness Professionals What Is MS? ...

  1. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS African Americans Hispanics & Latino/as d Multiple ... Questions to Ask d Resources for Specific Populations Pediatric MS Support Veterans with Multiple Sclerosis d Find ...

  2. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Conditions to Rule Out For Clinicians Treating MS Comprehensive Care Find an MS Care Provider Medications Managing ... ADEM) d For Clinicians d Treating MS d Comprehensive Care Developing a Healthcare Team Make the Most ...

  3. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    Science.gov (United States)

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  4. Preventive maintenance instrumentation results in Spanish nuclear power plants

    International Nuclear Information System (INIS)

    Curiel, M.; Palomo, M. J.; Verdu, G.; Arnaldos, A.

    2010-10-01

    This paper is a recompilation of the most significance results in relation to the researching in preventive and predictive maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and the Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the power plants control and instrumentation department's technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the object to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish nuclear power plants each of them shall give a significant contribution to problem resolution and power plant performance. (Author)

  5. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Viruses Clusters d Who Gets MS? Pediatric MS African Americans Hispanics & Latino/as d Multiple Sclerosis FAQs d ... Diet & Nutrition Exercise Heat & Temperature Sensitivity Sleep Vaccinations Women's Health Unhealthy Habits Managing MS and Another Condition ...

  6. Simplifying sample pretreatment: application of dried blood spot (DBS) method to blood samples, including postmortem, for UHPLC-MS/MS analysis of drugs of abuse.

    Science.gov (United States)

    Odoardi, Sara; Anzillotti, Luca; Strano-Rossi, Sabina

    2014-10-01

    The complexity of biological matrices, such as blood, requires the development of suitably selective and reliable sample pretreatment procedures prior to their instrumental analysis. A method has been developed for the analysis of drugs of abuse and their metabolites from different chemical classes (opiates, methadone, fentanyl and analogues, cocaine, amphetamines and amphetamine-like substances, ketamine, LSD) in human blood using dried blood spot (DBS) and subsequent UHPLC-MS/MS analysis. DBS extraction required only 100μL of sample, added with the internal standards and then three droplets (30μL each) of this solution were spotted on the card, let dry for 1h, punched and extracted with methanol with 0.1% of formic acid. The supernatant was evaporated and the residue was then reconstituted in 100μL of water with 0.1% of formic acid and injected in the UHPLC-MS/MS system. The method was validated considering the following parameters: LOD and LOQ, linearity, precision, accuracy, matrix effect and dilution integrity. LODs were 0.05-1ng/mL and LOQs were 0.2-2ng/mL. The method showed satisfactory linearity for all substances, with determination coefficients always higher than 0.99. Intra and inter day precision, accuracy, matrix effect and dilution integrity were acceptable for all the studied substances. The addition of internal standards before DBS extraction and the deposition of a fixed volume of blood on the filter cards ensured the accurate quantification of the analytes. The validated method was then applied to authentic postmortem blood samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Instrument design and automation

    International Nuclear Information System (INIS)

    Wernlund, R.F.

    1984-01-01

    The ion mobility spectrometer-mass spectrometer (IMS-MS) is described and consists of two separate instruments coupled in tandem: an ion mobility spectrometer coupled to a quadrupole mass spectrometer. The two insturments operate at different pressures in a synergistic manner, supplying both drift time and mass information about ions which are formed at atmospheric pressure in the ion mobility spectrometer tube. Two types of ion intensity signals are presented to the data processor. The IMS produces an analog voltage with major components from dc to 5 KHz. The mass spectrometer signal output resides in the pulse count rate derived from a series of TTL level pulses where each pulse represents the arrival of a single ion. The hardware, software, interfacing capabilities and basic data acquisition program are described in detail

  8. An ultra-sensitive instrument for collision activated dissociation mass spectrometry with high mass resolution

    International Nuclear Information System (INIS)

    Louter, G.J.

    1982-01-01

    During the last decade Collision Activated Dissociation Mass Spectrometry (CAD-MS) has developed into an important and sometimes unique technique for the structure elucidation of ions. An extensive description of the double stage MS is given, which has been especially devloped for CAD-MS. A high mass resolution and a very high sensitivity are obtained by application of special techniques like post-acceleration of fragment ions, quadrupole (Q-pole) lenses and an electro-optical, simultaneous ion detection system. The operation of the rather complex ion-optics is demonstrated by application of a computer simulation of the tandem MS. Special attention is given to the action of the four Q-pole lenses and the second sector magnet upon curvature and position of the mass focal plane. Two mass calibration methods are described for the fragment spectra. The so-called polynomial-method applies a fifth-order polynomial approximation of the functional relation between position on the detector and corresponding relative momentum of fragment ions. The second method uses the matrix model of the instrument. The detector consists of two channelplates (CEMA), a fibre optics slab, coated with a phosphor layer, a camera objective and a 1024-channels photodiode-array. A bio-chemical and an organic-chemical application of the instrument are given. As bio-chemical application the peak m/z 59 in the pyrolysis mass spectrum of complete mycobacteria is identified. As an example of organic-chemical application the fragmentation process of 2,3-butadienoic acid has been investigated. (Auth.)

  9. MS-SQL data base programming

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Chang Bae; Kim, Nam Jung; Lee, Hyeong Gyo

    2002-07-15

    This is about MS-SQL data base programming which is divided into thirteen chapters. The contents of this book are to understand MS-SQL 2000 DBMS with its composition, new function and history of MS-SQL, to learn conception of data base, install, run and closing of MS-SQL 2000 DBMS, to deal with the basic of MS-SQL DBMS, to handle the intermediate level of MS-SQL DBMS, to deal with MS-SQL DBMS in advanced level, to practice query like changing data base and checking of data lists, function on its use and data diff, get date, date add, char, upper and system function, set-up of MS-SQL ODBC, constructing of web server of windows 2000, web programming using visual studio.net.making board and making reference room.

  10. MS-SQL data base programming

    International Nuclear Information System (INIS)

    Noh, Chang Bae; Kim, Nam Jung; Lee, Hyeong Gyo

    2002-07-01

    This is about MS-SQL data base programming which is divided into thirteen chapters. The contents of this book are to understand MS-SQL 2000 DBMS with its composition, new function and history of MS-SQL, to learn conception of data base, install, run and closing of MS-SQL 2000 DBMS, to deal with the basic of MS-SQL DBMS, to handle the intermediate level of MS-SQL DBMS, to deal with MS-SQL DBMS in advanced level, to practice query like changing data base and checking of data lists, function on its use and data diff, get date, date add, char, upper and system function, set-up of MS-SQL ODBC, constructing of web server of windows 2000, web programming using visual studio.net.making board and making reference room.

  11. Analytical Method Details (MS): SE2_MS3 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available 00.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1)., Rejected mass=284.2000;300.2000;328.2000;344.2000;372.2000;388.2000;416.3000;432.3000;460.0000. ...

  12. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Treating MS d Comprehensive Care Developing a Healthcare Team Make the Most of Your Doctor Visits Advance Medical Directives d Find an MS Care Provider Partners in MS Care d Managing Relapses Plasmapheresis d Rehabilitation Functional Electrical Stimulation (FES) ...

  13. LC-MS-MS identification of drug metabolites obtained by metalloporphyrin mediated oxidation

    Directory of Open Access Journals (Sweden)

    Maurin Andrea J. M.

    2003-01-01

    Full Text Available In this paper we report the application of liquid chromatography-mass spectrometry (LC-MS-MS to the identification of the products formed by oxidation of albendazole and disopyramide with metalloporphyrins in dichloroethane, using iodosylbenzene as an oxygen donor. Our results show that LC-MS-MS is a powerful tool to study the in vitro metabolism of drugs, allowing the identification of known and unknown metabolites. In addition, it was observed that the catalyst system used resulted in the formation of the same metabolites as obtained in vivo, although for disopyramide other products were also observed.

  14. DBS-LC-MS/MS assay for caffeine: validation and neonatal application.

    Science.gov (United States)

    Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana

    2016-09-01

    DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.

  15. MsLDR-creator: a web service to design msLDR assays.

    Science.gov (United States)

    Bormann, Felix; Dahl, Andreas; Sers, Christine

    2012-03-01

    MsLDR-creator is a free web service to design assays for the new DNA methylation detection method msLDR. The service provides the user with all necessary information about the oligonucleotides required for the measurement of a given CpG within a sequence of interest. The parameters are calculated by the nearest neighbour approach to achieve optimal behaviour during the experimental procedure. In addition, to guarantee a good start using msLDR, further information, like protocols and hints and tricks, are provided.

  16. High accuracy determination of trace elements in NIST standard reference materials by isotope dilution ICP-MS

    International Nuclear Information System (INIS)

    Paulsen, P.J.; Beary, E.S.

    1996-01-01

    At NIST (National Institute of Standards and Technology), ICP-MS ID (inductively coupled mass spectrometry isotope dilution) has been used to certify a wide range of elements in a variety of materials with high accuracy. Both the chemical preparation and instrumental procedures are simpler than with other ID mass spectrometric techniques. The ICP-MS has picogram/ml detection limits for most elements using fixed operating parameters. Chemical separations are required only to remove an interference (from molecular ions as well as isobaric atoms), or to pre-concentrate the analyte. For example, chemical separations were required for the analysis of SRM 2711, Montana II Soil, but not for boron in peach leaves, SRM 1547.(3 refs., 3 tabs., 2 figs

  17. Preventive maintenance instrumentation results in Spanish nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Curiel, M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Palomo, M. J.; Verdu, G. [ISIRYM, Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain); Arnaldos, A., E-mail: m.curiel@lainsa.co [TITANIA Servicios Tecnologicos SL, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain)

    2010-10-15

    This paper is a recompilation of the most significance results in relation to the researching in preventive and predictive maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and the Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the power plants control and instrumentation department's technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the object to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish nuclear power plants each of them shall give a significant contribution to problem resolution and power plant performance. (Author)

  18. Triple quadrupole tandem mass spectrometry: A real alternative to high resolution magnetic sector instrument for the analysis of polychlorinated dibenzo-p-dioxins, furans and dioxin-like polychlorinated biphenyls.

    Science.gov (United States)

    García-Bermejo, Ángel; Ábalos, Manuela; Sauló, Jordi; Abad, Esteban; González, María José; Gómara, Belén

    2015-08-19

    This paper reports on the optimisation, characterisation, validation and applicability of gas chromatography coupled to triple quadrupole mass spectrometry in its tandem operation mode (GC-QqQ(MS/MS) for the quantification of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs, dioxins) and dioxin-like polychlorinated biphenyls (DL-PCBs) in environmental and food matrices. MS/MS parameters were selected to achieve the high sensitivity and selectivity required for the analysis of this type of compounds and samples. Good repeatability for areas (RSD = 1-10%, for PCDD/Fs and DL-PCBs) and for ion transition ratios (RSD = 0.3-10%, for PCDD/Fs, and 0.2-15%, for DL-PCBs) and low instrumental limits of detection, 0.07-0.75 pg μL(-1) (for dioxins) and 0.05-0.63 pg μL(-1) (for DL-PCBs), were obtained. A comparative study of the congener specific determination using both GC-QqQ(MS/MS) and gas chromatography-high resolution mass spectrometry (GC-HRMS) was also performed by analysing several fortified samples and certified reference materials (CRMs) with low (feed and foodstuffs), median (sewage sludge) and high (fly ash) toxic equivalency (TEQ) concentration levels, i.e. 0.60, 1.83, 72.9 and 3609 pg WHO-TEQ(PCDD/Fs) g(-1). The agreement between the results obtained for the total TEQs (dioxins) on GC-QqQ(MS/MS) and GC-HRMS in all the investigated samples were within the range of ±4%, and that of DL-PCBs at concentration levels of 0.84 pg WHO-TEQs (DL-PCBs) g(-1), in the case of feedstuffs, was 0.11%. Both instrumental methods have similar and comparable linearity, precision and accuracy. The GC-QqQ(MS/MS) sensitivity, lower than that of GC-HRMS, is good enough (iLODs in the down to low pg levels) to detect the normal concentrations of these compounds in food and environmental samples. These results make GC-QqQ(MS/MS) suitable for the quantitative analysis of dioxins and DL-PCBs and a real alternative tool to the reference sector HRMS instruments. Copyright © 2015 Elsevier

  19. Analytical Method Details (MS): SE29_MS1 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available SE29_MS1 LC-FT-ICR-MS ESI positive method 1 Agilent1100 HPLC (Agilent), LTQ-FT (The... (100mg) are solved in 300uL 80% methanol solution. 20uL sample is injected into HPLC after 0.2um membrane filter treatment. HPLC

  20. Open Access UHPSFC/MS - an additional analytical resource for an academic mass spectrometry facility.

    Science.gov (United States)

    Herniman, Julie M; Langley, G John

    2016-08-15

    Many compounds submitted for analysis in Chemistry at the University of Southampton do not retain, elute or ionize using open access reversed-phase ultra-high-performance liquid chromatography/mass spectrometry (RP-UHPLC/MS) and require analysis via infusion. An ultra-high-performance supercritical fluid chromatography mass spectrometry approach was implemented to afford high-throughput analysis of these compounds with chromatographic separation. A UPC(2) -TQD MS system has been incorporated into the open access MS provision within Chemistry at the University of Southampton, using an ESCi source (electrospray and atmospheric pressure chemical ionization) and an atmospheric pressure photoionization (APPI) source. Access to instrumentation is enabled via a web-based interface (RemoteAnalyzer™). Compounds such as fluorosugars, fullerenes, phosphoramidites, porphyrins, and rotaxanes exhibiting properties incompatible with RP-UHPLC/MS have been analyzed using automated chromatography and mass spectrometry methods. The speedy return of data enables research in these areas to progress unhindered by sample type. The provision of an electronic web format enables easy incorporation of chromatograms and mass spectra into electronic files and reports. The implementation of UHPSFC/MS increases access to a wide range of chemistries incompatible with reversed-phase chromatography and polar solvents, enabling more than 90% of submitted samples to be analyzed using an open access approach. Further, chromatographic separation is provided where previously flow injection or infusion analyses were the only options. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Polyphonic pitch detection and instrument separation

    Science.gov (United States)

    Bay, Mert; Beauchamp, James W.

    2005-09-01

    An algorithm for polyphonic pitch detection and musical instrument separation is presented. Each instrument is represented as a time-varying harmonic series. Spectral information is obtained from a monaural input signal using a spectral peak tracking method. Fundamental frequencies (F0s) for each time frame are estimated from the spectral data using an Expectation Maximization (EM) algorithm with a Gaussian mixture model representing the harmonic series. The method first estimates the most predominant F0, suppresses its series in the input, and then the EM algorithm is run iteratively to estimate each next F0. Collisions between instrument harmonics, which frequently occur, are predicted from the estimated F0s, and the resulting corrupted harmonics are ignored. The amplitudes of these corrupted harmonics are replaced by harmonics taken from a library of spectral envelopes for different instruments, where the spectrum which most closely matches the important characteristics of each extracted spectrum is chosen. Finally, each voice is separately resynthesized by additive synthesis. This algorithm is demonstrated for a trio piece that consists of 3 different instruments.

  2. Fe- and Cu-complex formation with artificial ligands investigated by ultra-high resolution Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR-MS: Implications for natural metal-organic complex studies

    Directory of Open Access Journals (Sweden)

    Hannelore Waska

    2016-07-01

    Full Text Available In recent years, electrospray-ionization mass spectrometry (ESI-MS has been increasingly used to complement the bulk determination of metal-ligand equilibria, for example via competitive ligand exchange-adsorptive cathodic stripping voltammetry (CLE-ACSV. However, ESI-MS speciation analyses may be impacted by instrumental artefacts such as reduction reactions, fragmentation, and adduct formation at the ESI source, changes in the ionization efficiencies of the detected species in relation to sample matrix, and peak overlaps in response to increasing sample complexity. In our study, equilibria of the known artificial ligands citrate, ethylenediaminetetraacetic acid (EDTA, 1-nitroso-2-naphthol (NN, and salicylaldoxime (SA with iron (Fe and copper (Cu were investigated by ultra-high resolution ESI-MS, Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR-MS, under a variety of sample matrix and ionization settings. The acquired mass spectra were compared with metal-ligand equilibrium data from the literature as well as an adapted speciation model. Overall, the mass spectra produced representative species mentioned in previous reports and predicted by the speciation calculations, such as Fe(Cit, Cu(Cit2, Fe(EDTA, Cu(EDTA, Fe(NN3, and Cu(SA2. The analyses furthermore revealed new species which had been hypothesized but not measured directly using other methods, for example ternary complexes of citrate with Fe and Cu, Cu(SA monomers, and the dimer Fe(SA2. Finally, parallel measurements of a Cu+SA calibration series and a Cu+SA+EDTA competition series indicated that FT-ICR-MS can produce linear responses and low detection limits analogous to those of ACSV. We propose that ultra-high resolution FT-ICR-MS can be used as a representative tool to study interactions of trace metals with artificial as well as natural, unknown ligands at the molecular level.

  3. Quantifying Gait Impairment Using an Instrumented Treadmill in People with Multiple Sclerosis

    Science.gov (United States)

    Kalron, Alon; Dvir, Zeevi; Frid, Lior; Achiron, Anat

    2013-01-01

    Background and Objective. Treadmill gait analysis has been proposed as an attractive alternative for overground walking measuring systems. The purpose of this study was twofold: first to determine spatiotemporal parameters of treadmill gait in patients with multiple sclerosis (MS) and second to examine whether these parameters are associated with specific functional impairments in this cohort. Method. Eighty-seven relapsing-remitting patients diagnosed with MS, 50 women and 37 men, aged 40.9 ± 11.9 with an expanded disability status scale (EDSS) score of 2.7 ± 1.6, participated in this study. Twenty-five apparently healthy subjects, 14 women and 11 men, aged 38.5 ± 9.4, served as controls. Spatiotemporal gait parameters were obtained using the Zebris FDM-T Treadmill (Zebris Medical GmbH, Germany). People with MS demonstrated significantly shorter steps, extended stride time, wider base of support, longer step time, reduced single support phase, and a prolonged double support phase compared to the healthy controls. The EDSS score was significantly correlated with all spatiotemporal gait parameters. Conclusion. The instrumented treadmill may be an effective tool in assessing ambulation capabilities of people with MS. PMID:23878746

  4. Exploiting the capabilities of the Sentinel-2 multi spectral instrument for predicting growing stock volume in forest ecosystems

    Science.gov (United States)

    Mura, Matteo; Bottalico, Francesca; Giannetti, Francesca; Bertani, Remo; Giannini, Raffaello; Mancini, Marco; Orlandini, Simone; Travaglini, Davide; Chirici, Gherardo

    2018-04-01

    The spatial prediction of growing stock volume is one of the most frequent application of remote sensing for supporting the sustainable management of forest ecosystems. For such a purpose data from active or passive sensors are used as predictor variables in combination with measures taken in the field in sampling plots. The Sentinel-2 (S2) satellites are equipped with a Multi Spectral Instrument (MSI) capable of acquiring 13 bands in the visible and infrared domains with a spatial resolution varying between 10 and 60 m. The present study aimed at evaluating the performance of the S2-MSI imagery for estimating the growing stock volume of forest ecosystems. To do so we used 240 plots measured in two study areas in Italy. The imputation was carried out with eight k-Nearest Neighbours (k-NN) methods available in the open source YaImpute R package. In order to evaluate the S2-MSI performance we repeated the experimental protocol also with two other sets of images acquired by two well-known satellites equipped with multi spectral instruments: Landsat 8 OLI and RapidEye scanner. We found that S2 worked better than Landsat in 37.5% of the cases and in 62.5% of the cases better than RapidEye. In one study area the best performance was obtained with Landsat OLI (RMSD = 6.84%) and in the other with S2 (RMSD = 22.94%), both with the k-NN system based on a distance matrix calculated with the Random Forest algorithm. The results confirmed that S2 images are suitable for predicting growing stock volume obtaining good performances (average RMSD for both the test areas of less than 19%).

  5. A comparison between DART-MS and DSA-MS in the forensic analysis of writing inks.

    Science.gov (United States)

    Drury, Nicholas; Ramotowski, Robert; Moini, Mehdi

    2018-05-23

    Ambient ionization mass spectrometry is gaining momentum in forensic science laboratories because of its high speed of analysis, minimal sample preparation, and information-rich results. One such application of ambient ionization methodology includes the analysis of writing inks from questioned documents where colorants of interest may not be soluble in common solvents, rendering thin layer chromatography (TLC) and separation-mass spectrometry methods such as LC/MS (-MS) impractical. Ambient ionization mass spectrometry uses a variety of ionization techniques such as penning ionization in Direct Analysis in Real Time (DART), and atmospheric pressure chemical ionization in Direct Sample Analysis (DSA), and electrospray ionization in Desorption Electrospray Ionization (DESI). In this manuscript, two of the commonly used ambient ionization techniques are compared: Perkin Elmer DSA-MS and IonSense DART in conjunction with a JEOL AccuTOF MS. Both technologies were equally successful in analyzing writing inks and produced similar spectra. DSA-MS produced less background signal likely because of its closed source configuration; however, the open source configuration of DART-MS provided more flexibility for sample positioning for optimum sensitivity and thereby allowing smaller piece of paper containing writing ink to be analyzed. Under these conditions, the minimum sample required for DART-MS was 1mm strokes of ink on paper, whereas DSA-MS required a minimum of 3mm. Moreover, both techniques showed comparable repeatability. Evaluation of the analytical figures of merit, including sensitivity, linear dynamic range, and repeatability, for DSA-MS and DART-MS analysis is provided. To the forensic context of the technique, DART-MS was applied to the analysis of United States Secret Service ink samples directly on a sampling mesh, and the results were compared with DSA-MS of the same inks on paper. Unlike analysis using separation mass spectrometry, which requires sample

  6. Natural isotope correction of MS/MS measurements for metabolomics and (13)C fluxomics.

    Science.gov (United States)

    Niedenführ, Sebastian; ten Pierick, Angela; van Dam, Patricia T N; Suarez-Mendez, Camilo A; Nöh, Katharina; Wahl, S Aljoscha

    2016-05-01

    Fluxomics and metabolomics are crucial tools for metabolic engineering and biomedical analysis to determine the in vivo cellular state. Especially, the application of (13)C isotopes allows comprehensive insights into the functional operation of cellular metabolism. Compared to single MS, tandem mass spectrometry (MS/MS) provides more detailed and accurate measurements of the metabolite enrichment patterns (tandem mass isotopomers), increasing the accuracy of metabolite concentration measurements and metabolic flux estimation. MS-type data from isotope labeling experiments is biased by naturally occurring stable isotopes (C, H, N, O, etc.). In particular, GC-MS(/MS) requires derivatization for the usually non-volatile intracellular metabolites introducing additional natural isotopes leading to measurements that do not directly represent the carbon labeling distribution. To make full use of LC- and GC-MS/MS mass isotopomer measurements, the influence of natural isotopes has to be eliminated (corrected). Our correction approach is analyzed for the two most common applications; (13)C fluxomics and isotope dilution mass spectrometry (IDMS) based metabolomics. Natural isotopes can have an impact on the calculated flux distribution which strongly depends on the substrate labeling and the actual flux distribution. Second, we show that in IDMS based metabolomics natural isotopes lead to underestimated concentrations that can and should be corrected with a nonlinear calibration. Our simulations indicate that the correction for natural abundance in isotope based fluxomics and quantitative metabolomics is essential for correct data interpretation. © 2015 Wiley Periodicals, Inc.

  7. Differential Impact and Use of a Telehealth Intervention by Persons with MS or SCI.

    Science.gov (United States)

    Mercier, Hannah W; Ni, Pensheng; Houlihan, Bethlyn V; Jette, Alan M

    2015-11-01

    The objective of this study was to compare outcomes and patterns of engaging with a telehealth intervention (CareCall) by adult wheelchair users with severe mobility limitations with a diagnosis of multiple sclerosis (MS) or spinal cord injury (SCI). The design of this study is a secondary analysis from a pilot randomized controlled trial with 106 participants with SCI and 36 participants with MS. General linear model results showed that an interaction between baseline depression score and study group significantly predicted reduced depression at 6 mos for subjects with both diagnoses (P = 0.01). For those with MS, CareCall increased participants' physical independence (P SCI (P = 0.005). Those with SCI missed more calls (P SCI, and in increasing health care access and physical independence for those with a diagnosis of MS. Future research should aim to enhance the efficacy of such an intervention for participants with SCI.

  8. Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva

    Directory of Open Access Journals (Sweden)

    Raphael Hösli

    2018-01-01

    Full Text Available Phenytoin (PHT is one of the most often used critical dose drugs, where insufficient or excessive dosing can have severe consequences such as seizures or toxicity. Thus, the monitoring and precise measuring of PHT concentrations in patients is crucial. This study develops and validates an LC-MS/MS method for the measurement of phenytoin concentrations in different body compartments (i.e., human brain dialysate, blood, and saliva and compares it with a formerly developed GC-MS method that measures PHT in the same biological matrices. The two methods are evaluated and compared based on their analytical performance, appropriateness to analyze human biological samples, including corresponding extraction and cleanup procedures, and their validation according to ISO 17025/FDA Guidance for Industry. The LC-MS/MS method showed a higher performance compared with the GC-MS method. The LC-MS/MS was more sensitive, needed a smaller sample volume (25 µL and less chemicals, was less time consuming (cleaning up, sample preparation, and analysis, and resulted in a better LOD ( 0.995 for all tested matrices (blood, saliva, and dialysate. For larger sample numbers as in pharmacokinetic/pharmacodynamic studies and for bedside as well as routine analyses, the LC-MS/MS method offers significant advantages over the GC-MS method.

  9. Structure Annotation and Quantification of Wheat Seed Oxidized Lipids by High-Resolution LC-MS/MS.

    Science.gov (United States)

    Riewe, David; Wiebach, Janine; Altmann, Thomas

    2017-10-01

    Lipid oxidation is a process ubiquitous in life, but the direct and comprehensive analysis of oxidized lipids has been limited by available analytical methods. We applied high-resolution liquid chromatography-mass spectrometry (LC-MS) and tandem mass spectrometry (MS/MS) to quantify oxidized lipids (glycerides, fatty acids, phospholipids, lysophospholipids, and galactolipids) and implemented a platform-independent high-throughput-amenable analysis pipeline for the high-confidence annotation and acyl composition analysis of oxidized lipids. Lipid contents of 90 different naturally aged wheat ( Triticum aestivum ) seed stocks were quantified in an untargeted high-resolution LC-MS experiment, resulting in 18,556 quantitative mass-to-charge ratio features. In a posthoc liquid chromatography-tandem mass spectrometry experiment, high-resolution MS/MS spectra (5 mD accuracy) were recorded for 8,957 out of 12,080 putatively monoisotopic features of the LC-MS data set. A total of 353 nonoxidized and 559 oxidized lipids with up to four additional oxygen atoms were annotated based on the accurate mass recordings (1.5 ppm tolerance) of the LC-MS data set and filtering procedures. MS/MS spectra available for 828 of these annotations were analyzed by translating experimentally known fragmentation rules of lipids into the fragmentation of oxidized lipids. This led to the identification of 259 nonoxidized and 365 oxidized lipids by both accurate mass and MS/MS spectra and to the determination of acyl compositions for 221 nonoxidized and 295 oxidized lipids. Analysis of 15-year aged wheat seeds revealed increased lipid oxidation and hydrolysis in seeds stored in ambient versus cold conditions. © 2017 The author(s). All Rights Reserved.

  10. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... and problems with cognition (learning and memory or information processing). People with progressive forms of MS are more likely to experience gradually worsening problems with walking and mobility, along with whatever other symptoms they may have. Diagnosing ... MS Society is Here to Help Need More Information? We Are Here Our MS Navigators help identify ...

  11. Brain activation during dichotic presentations of consonant-vowel and musical instrument stimuli: a 15O-PET study.

    Science.gov (United States)

    Hugdahl, K; Brønnick, K; Kyllingsbaek, S; Law, I; Gade, A; Paulson, O B

    1999-04-01

    Dichotic listening means that two different stimuli are presented at the same time, one in each ear. This technique is frequently used in experimental and clinical studies as a measure of hemispheric specialization. The primary aim of the present study was to record regional changes in the distribution of cerebral blood flow (CBF) with the 15O-PET technique to dichotically presented consonant-vowel (CV) and musical instrument stimuli, in order to test the basic assumption of differential hemispheric involvement when stimuli presented to one ear dominate over stimuli presented in the other ear. All stimuli were 380 ms in duration with a 1000 ms interstimulus interval, and were presented in blocks of either CV-syllable or musical instrument pairs. Twelve normal healthy subjects had to press a button whenever they detected a CV-syllable or a musical instrument target in a stream of CV- and musical instrument distractor stimuli. The targets appeared equally often in the right and left ear channel. The CV-syllable and musical instrument targets activated bilateral areas in the superior temporal gyri. However, there were significant interactions with regard to asymmetry of the magnitude of peak activation in the significant activation clusters. The CV-syllables resulted in greater neural activation in the left temporal lobe while the musical instruments resulted in greater neural activation in the right temporal lobe. Within-subjects correlations between magnitude of dichotic listening and CBF asymmetry were, however, non-significant. The changes in neural activation were closely mimicked by the performance data which showed a right ear superiority in response accuracy for the CV-syllables, and a left ear superiority for the musical instruments. In addition to the temporal lobe activations, there were activation tendencies in the left inferior frontal lobe, right dorsolateral prefrontal cortex, left occipital lobe, and cerebellum.

  12. MgB2 Thin-Film Bolometer for Applications in Far-Infrared Instruments on Future Planetary Missions

    Science.gov (United States)

    Lakew, B.; Aslam, S.; Brasunas, J.; Cao, N.; Costen, N.; La, A.; Stevenson, T.; Waczynski, A.

    2012-01-01

    A SiN membrane based MgB2 thin-film bolometer, with a non-optimized absorber, has been fabricated that shows an electrical noise equivalent power of 256 fW/square root Hz operating at 30 Hz in the 8.5 - 12.35 micron spectral bandpass. This value corresponds to an electrical specific detectivity of 7.6 x 10(exp 10) cm square root Hz/W. The bolometer shows a measured blackbody (optical) specific detectivity of 8.8 x 10(exp 9) cm square root Hz/W, with a responsivity of 701.5 kV/W and a first-order time constant of 5.2 ms. It is predicted that with the inclusion of a gold black absorber that a blackbody specific detectivity of 6.4 x 10(exp 10) cm/square root Hz/W at an operational frequency of 10 Hz, can be realized for integration into future planetary exploration instrumentation where high sensitivity is required in the 17 - 250 micron spectral wavelength range.

  13. Oxidation of danofloxacin by free chlorine-kinetic study, structural identification of by-products by LC-MS/MS and potential toxicity of by-products using in silico test.

    Science.gov (United States)

    Yassine, Montaha; Rifai, Ahmad; Doumyati, Samah; Trivella, Aurélien; Mazellier, Patrick; Budzinski, Hélène; Al Iskandarani, Mohamad

    2017-03-01

    In this study, we aimed to investigate the kinetics and the mechanism of reaction of the fluoroquinolone antibacterial danofloxacin (DANO) by free available chlorine (FAC) during water chlorination process. Kinetic study was thus performed at pH 7.2, 20 °C in the presence of an excess of total chlorine. Under these experimental conditions, a second-order reaction rate constant (first-order relative to DANO concentration and first-order relative to FAC concentration) was evaluated to k~1446 M -1  s -1 . Five degradation products were identified at different reaction times. Their structures were investigated by using fragmentations obtained at different CID collision energies in MS/MS experiments. Moreover, the toxicity of the proposed structures was predicted by using T.E.S.T. The results indicated that all by-products may have a developmental toxicity. The oral rat LD 50 concentration was predicted to be lower than that of DANO. Furthermore, two degradation compounds presented a concentration level for fathead minnow LC 50 (96 h) lower than that of DANO and presented toxicity for the marine animals.

  14. Determination of drug residues by CLAR-MS/MS in animal tissues

    International Nuclear Information System (INIS)

    Brenes Jimenez, Jose Eduardo

    2009-01-01

    Produced food of animal origin, present the possibility of occurrence of any contact with substances that have negative effects on the health of people who consume them. The use of drugs in veterinary medicine is one of the possible sources of such waste; so, the conditions for the analysis of some classes of antibiotics in animal tissues are based on the study. Costa Rica and the countries that are export destination, have regulation and programs for control before to be distributed in local markets, or post if it is received any complaint of pollution. The high resolution liquid chromatography coupled to mass spectrometers (CLAR-MS/MS) allows the analysis of analytes monitored, according to the specifications required by the legislation. The cases of two laboratories in Costa Rica are presented as the only ones who have the ability to perform the analysis of drug residues CLAR-MS/MS. (author) [es

  15. Measurement of O(6)-alkylguanine-DNA alkyltransferase activity in tumour cells using stable isotope dilution HPLC-ESI-MS/MS.

    Science.gov (United States)

    Sun, Guohui; Zhao, Lijiao; Fan, Tengjiao; Ren, Ting; Zhong, Rugang

    2016-10-15

    The repair of DNA mediated by O(6)-alkylguanine-DNA alkyltransferase (AGT) provides protection against DNA damage from endogenous or exogenous alkylation of the O(6) position of guanine. However, this repair acts as a double-edged sword in cancer treatment, as it not only protects normal cells from chemotherapy-associated toxicities, but also results in cancer cell resistance to guanine O(6)-alkylating antitumour agents. Thus, AGT plays an important role in predicting the individual susceptibility to guanine O(6)-alkylating carcinogens and chemotherapies. Accordingly, it is necessary to establish a quantitative method for determining AGT activity with high accuracy, sensitivity and practicality. Here, we describe a novel nonradioactive method for measuring AGT activity using stable isotope dilution high-performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). This method is based on the irreversibility of the removal of the O(6)-alkyl group from guanine by AGT and on the high affinity of O(6)-benzylguanine (O(6)-BG) as an AGT substrate. HPLC-ESI-MS/MS was used to measure the AGT activities in cell protein extracts from eight tumour lines, demonstrating that AGT activity was quite variable among different cell lines, ranging from nondetectable to 1021 fmol/mg protein. The experiments performed in intact tumour cells yielded similar results but exhibited slightly higher activities than those observed in cell protein extracts. The accuracy of this method was confirmed by an examination of AGT expression levels using western blotting analysis. To our knowledge, this method is the first mass spectrometry-based AGT activity assay, and will likely provide assistance in the screening of cancer risk or the application of chemotherapies. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. GC determination of N-nitrosamines by supersonic molecular beam MS equipped with triple quadrupole analyzer, GC/SMB/QQQ/MS

    International Nuclear Information System (INIS)

    Anna, Voloshenko; Rimma, Shelkov; Lev, Ovadia; Jenny, Gun

    2011-01-01

    The determination of 14 N-nitrosamines by a supersonic molecular beam electron ionization mass spectrometer equipped with triple quadruple analyzer, GC/SMB/EI/QQQ/MS is presented. The supersonic molecular beam electron ionization ion source allows the elucidation of the molecular ion of 13 out of the 14 examined nitrosamines (except for diphenylnitrosamine which was degraded before the analysis). It was possible to use the molecular ions of all the nitrosamines as the parent ions for multiple reactions monitoring mode, which in turn allows significant increase of specificity and lowering of the method limit of detection of the higher molecular weight nitrosamines. The instrumental LOD for different N-nitrosamines was 1-5 pg injection -1 . The proposed method was exemplified by analysis of N-nitrosamines and N-nitrosatables in rubber teats according to the British Standard BS EN 12868:1999.

  17. ASK Procedure for Instrumented Pre-cracked Charpy-Type Tests

    International Nuclear Information System (INIS)

    Varga, T.; Njo, D.H.; Prantl, G.

    1981-01-01

    The essential technical content of the ASK procedure originated from development work in Switzerland since 1963, and practical experiences gained since 1972. The remainder of the content and the format of the procedure are based on the ASTM E 24.03.03. (Tentative Draft Copy) 'Proposed Method for Pre-cracked Charpy Impact and Slow-Bend Testing of Metallic Materials' by C. E. Harbower, 1973. Two different velocities, 5 m/s and 0.1 m/s were used with a Schnadt-type machine of rigid construction. The stiffness of the machine proved to be very suitable for instrumented testing. The instrumented Schnadt-Type machine was equipped with strain gauges both on the top of the pendulum and on the chisel. A static force calibration was followed by energy calibration, comparing potential energy losses with the area under the force-deflection curve. Deflection was measured using a high frequency eddy current method on the pendulum, and for slow testing by means of an inductive gauge on the chisel. Charpy-Type specimens of 1.0 mm max notch depth and 0.12 mm max notch radius were pre-cracked using a resonant fatigue testing machine, or an eccentric drive machine. Crack propagation rate da/dN was measured using 'Russenberger' measuring gauges. In addition a new technique for the detection of dynamic crack initiation, developed at the Institute of Research and Technology (TVFA) in Vienna is discussed and some results presented

  18. Analysis and Synthesis of Musical Instrument Sounds

    Science.gov (United States)

    Beauchamp, James W.

    For synthesizing a wide variety of musical sounds, it is important to understand which acoustic properties of musical instrument sounds are related to specific perceptual features. Some properties are obvious: Amplitude and fundamental frequency easily control loudness and pitch. Other perceptual features are related to sound spectra and how they vary with time. For example, tonal "brightness" is strongly connected to the centroid or tilt of a spectrum. "Attack impact" (sometimes called "bite" or "attack sharpness") is strongly connected to spectral features during the first 20-100 ms of sound, as well as the rise time of the sound. Tonal "warmth" is connected to spectral features such as "incoherence" or "inharmonicity."

  19. Paper on operation and maintenance experiences on radiation monitoring instrumentation at NAPS

    International Nuclear Information System (INIS)

    Gupta, J.P.; Vinod Kumar; Sen, S.K.; Malhotra, S.

    2005-01-01

    Narora Atomic Power Station (NAPS) is the first standardized Pressurised Heavy Water Reactor in India commissioned in the year 1989. Many new Radiation Monitoring Systems like Portal Monitors and Ventilation Exhaust Activity Monitors were first time introduced at NAPS. All the Personnel Contamination Monitors and Area Radiation Monitors used at NAPS were designed and developed by Electronics Division, BARC. Only the Portal Monitor was supplied by M/S Herfurth, Germany. The paper highlights the operation and maintenance experiences on Radiation Monitoring Instrumentation at NAPS in the last 15 years of operation. The paper also highlights the different problems faced in Radiation Instruments and our suggestions for improvement in their design for their better availability and long term reliability. (author)

  20. Gas chromatography of organic microcontaminants using atomic emission and mass spectrometric detection combined in one instrument (GC-AED/MS)

    NARCIS (Netherlands)

    Mol, H.G.J.; Hankemeier, T.; Brinkman, U.A.T.

    1999-01-01

    This study describes the coupling of an atomic-emission detector and mass-spectrometric detector to a single gas chromatograph. Splitting of the column effluent enables simultaneous detection by atomic-emission detection (AED) and mass spectrometry (MS) and yields a powerful system for the target

  1. Analysis of marine samples by neutron-induced prompt gamma-ray technique and ICP-MS

    International Nuclear Information System (INIS)

    Yonezawa, C.; Matsue, H.; McKay, K.; Povinec, P.

    2001-01-01

    Multi-element and isotopic analyses of oils and marine environmental samples were carried out to estimate a contamination source using a 'finger printing' method. Elemental analyses were carried out using neutron-induced prompt gamma-ray analysis (PGA), instrumental neutron activation analysis (INAA) at the Japan Atomic Institute, Tokai-mura, Japan (JAERI) and ICP-MS in the IAEA Marine Environment Laboratory, Monaco (MEL). Fifteen elements including light elements, H, B, N, Si and Ca, which cannot be determined by INAA and ICP-MS, were determined by PGA. A total of 47 elements were determined in the present study. The potential of PGA for the determination of isotopic ratios was tested by measuring 34 S/ 32 S ratios in oils. The evaluation of historical records of marine environmental conditions using annual bands in coral samples was also investigated. (author)

  2. Evaluation of beam tracking strategies for the THOR-CSW solar wind instrument

    Science.gov (United States)

    De Keyser, Johan; Lavraud, Benoit; Prech, Lubomir; Neefs, Eddy; Berkenbosch, Sophie; Beeckman, Bram; Maggiolo, Romain; Fedorov, Andrei; Baruah, Rituparna; Wong, King-Wah; Amoros, Carine; Mathon, Romain; Génot, Vincent

    2017-04-01

    We compare different beam tracking strategies for the Cold Solar Wind (CSW) plasma spectrometer on the ESA M4 THOR mission candidate. The goal is to intelligently select the energy and angular windows the instrument is sampling and to adapt these windows as the solar wind properties evolve, with the aim to maximize the velocity distribution acquisition rate while maintaining excellent energy and angular resolution. Using synthetic data constructed using high-cadence measurements by the Faraday cup instrument on the Spektr-R mission (30 ms resolution), we test the performance of energy beam tracking with or without angular beam tracking. The algorithm can be fed both by data acquired by the plasma spectrometer during the previous measurement cycle, or by data from another instrument, in casu the Faraday Cup (FAR) instrument foreseen on THOR. We verify how these beam tracking algorithms behave for different sizes of the energy and angular windows, and for different data integration times, in order to assess the limitations of the algorithm and to avoid situations in which the algorithm loses track of the beam.

  3. Development and validation of an UHPLC-MS/MS method for β2-agonists quantification in human urine and application to clinical samples.

    Science.gov (United States)

    Bozzolino, Cristina; Leporati, Marta; Gani, Federica; Ferrero, Cinzia; Vincenti, Marco

    2018-02-20

    A fast analytical method for the simultaneous detection of 24 β 2 -agonists in human urine was developed and validated. The method covers the therapeutic drugs most commonly administered, but also potentially abused β 2 -agonists. The procedure is based on enzymatic deconjugation with β-glucuronidase followed by SPE clean up using mixed-phase cartridges with both ion-exchange and lipophilic properties. Instrumental analysis conducted by UHPLC-MS/MS allowed high peak resolution and rapid chromatographic separation, with reduced time and costs. The method was fully validated according ISO 17025:2005 principles. The following parameters were determined for each analyte: specificity, selectivity, linearity, limit of detection, limit of quantification, precision, accuracy, matrix effect, recovery and carry-over. The method was tested on real samples obtained from patients subjected to clinical treatment under chronic or acute therapy with either formoterol, indacaterol, salbutamol, or salmeterol. The drugs were administered using pressurized metered dose inhalers. All β 2 -agonists administered to the patients were detected in the real samples. The method proved adequate to accurately measure the concentration of these analytes in the real samples. The observed analytical data are discussed with reference to the administered dose and the duration of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Metabolomic and elemental analysis of camel and bovine urine by GC-MS and ICP-MS.

    Science.gov (United States)

    Ahamad, Syed Rizwan; Alhaider, Abdul Qader; Raish, Mohammad; Shakeel, Faiyaz

    2017-01-01

    Recent studies from the author's laboratory indicated that camel urine possesses antiplatelet activity and anti-cancer activity which is not present in bovine urine. The objective of this study is to compare the volatile and elemental components of bovine and camel urine using GC-MS and ICP-MS analysis. We are interested to know the component that performs these biological activities. The freeze dried urine was dissolved in dichloromethane and then derivatization process followed by using BSTFA for GC-MS analysis. Thirty different compounds were analyzed by the derivatization process in full scan mode. For ICP-MS analysis twenty eight important elements were analyzed in both bovine and camel urine. The results of GC-MS and ICP-MS analysis showed marked difference in the urinary metabolites. GC-MS evaluation of camel urine finds a lot of products of metabolism like benzene propanoic acid derivatives, fatty acid derivatives, amino acid derivatives, sugars, prostaglandins and canavanine. Several research reports reveal the metabolomics studies on camel urine but none of them completely reported the pharmacology related metabolomics. The present data of GC-MS suggest and support the previous studies and activities related to camel urine.

  5. Application of LC–MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids

    OpenAIRE

    Haneef, Jamshed; Shaharyar, Mohammad; Husain, Asif; Rashid, Mohd; Mishra, Ravinesh; Parveen, Shama; Ahmed, Niyaz; Pal, Manoj; Kumar, Deepak

    2013-01-01

    Liquid chromatography tandem mass chromatography (LCâMS/MS) is an important hyphenated technique for quantitative analysis of drugs in biological fluids. Because of high sensitivity and selectivity, LCâMS/MS has been used for pharmacokinetic studies, metabolites identification in the plasma and urine. This manuscript gives comprehensive analytical review, focusing on chromatographic separation approaches (column packing materials, column length and mobile phase) as well as different acquisiti...

  6. Application of LC–MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids

    OpenAIRE

    Haneef, Jamshed; Shaharyar, Mohammad; Husain, Asif; Rashid, Mohd; Mishra, Ravinesh; Parveen, Shama; Ahmed, Niyaz; Pal, Manoj; Kumar, Deepak

    2013-01-01

    Liquid chromatography tandem mass chromatography (LC–MS/MS) is an important hyphenated technique for quantitative analysis of drugs in biological fluids. Because of high sensitivity and selectivity, LC–MS/MS has been used for pharmacokinetic studies, metabolites identification in the plasma and urine. This manuscript gives comprehensive analytical review, focusing on chromatographic separation approaches (column packing materials, column length and mobile phase) as well as different acquisiti...

  7. Improved LC-MS/MS method for the quantification of hepcidin-25 in clinical samples.

    Science.gov (United States)

    Abbas, Ioana M; Hoffmann, Holger; Montes-Bayón, María; Weller, Michael G

    2018-06-01

    Mass spectrometry-based methods play a crucial role in the quantification of the main iron metabolism regulator hepcidin by singling out the bioactive 25-residue peptide from the other naturally occurring N-truncated isoforms (hepcidin-20, -22, -24), which seem to be inactive in iron homeostasis. However, several difficulties arise in the MS analysis of hepcidin due to the "sticky" character of the peptide and the lack of suitable standards. Here, we propose the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces after testing several types of vials for the preparation of stock solutions and serum samples for isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions with the aim of developing a LC-MS/MS method for the sensitive and reliable quantification of hepcidin-25 in serum samples. A chromatographic separation based on usual acidic mobile phases was compared with a novel approach involving the separation of hepcidin-25 with solvents at high pH containing 0.1% of ammonia. Both methods were applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with good correlation of the results. Finally, we recommend a LC-MS/MS-based quantification method with a dynamic range of 0.5-40 μg/L for the assessment of hepcidin-25 in human serum that uses TFA-based mobile phases and silanized glass vials. Graphical abstract Structure of hepcidin-25 (Protein Data Bank, PDB ID 2KEF).

  8. Extending the frontiers of mass spectrometric instrumentation and methods

    Energy Technology Data Exchange (ETDEWEB)

    Schieffer, Gregg Martin [Iowa State Univ., Ames, IA (United States)

    2010-01-01

    The focus of this dissertation is two-fold: developing novel analysis methods using mass spectrometry and the implementation and characterization of a novel ion mobility mass spectrometry instrumentation. The novel mass spectrometry combines ion trap for ion/ion reactions coupled to an ion mobility cell. The long term goal of this instrumentation is to use ion/ion reactions to probe the structure of gas phase biomolecule ions. The three ion source - ion trap - ion mobility - qTOF mass spectrometer (IT - IM - TOF MS) instrument is described. The analysis of the degradation products in coal (Chapter 2) and the imaging plant metabolites (Appendix III) fall under the methods development category. These projects use existing commercial instrumentation (JEOL AccuTOF MS and Thermo Finnigan LCQ IT, respectively) for the mass analysis of the degraded coal products and the plant metabolites, respectively. The coal degradation paper discusses the use of the DART ion source for fast and easy sample analysis. The sample preparation consisted of a simple 50 fold dilution of the soluble coal products in water and placing the liquid in front of the heated gas stream. This is the first time the DART ion source has been used for analysis of coal. Steven Raders under the guidance of John Verkade came up with the coal degradation projects. Raders performed the coal degradation reactions, worked up the products, and sent them to me. Gregg Schieffer developed the method and wrote the paper demonstrating the use of the DART ion source for the fast and easy sample analysis. The plant metabolite imaging project extends the use of colloidal graphite as a sample coating for atmospheric pressure LDI. DC Perdian and I closely worked together to make this project work. Perdian focused on building the LDI setup whereas Schieffer focused on the MSn analysis of the metabolites. Both Perdian and I took the data featured in the paper. Perdian was the primary writer of the paper and used it as a

  9. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Clinicians Publications for Your Patients MS Navigator Program Programs and Services for Your Patients Contact Us Clinical Fellows ... Relapsing-remitting MS (RRMS) Relapsing-remitting ...

  10. New GUT predictions for mτ/mb and mμ/ms

    International Nuclear Information System (INIS)

    Antusch, Stefan

    2010-01-01

    Group theoretical factors from GUT symmetry breaking can lead to predictions for the ratios of quark and lepton masses (or Yukawa couplings) at the unification scale. Due to supersymmetric (SUSY) threshold corrections the viability of such predictions can depend strongly on the SUSY parameters. For three common minimal SUSY breaking scenarios with anomaly, gauge and gravity mediation we discuss which GUT scale ratios m e /m d m μ /m s , y τ /y b and y t /y b are allowed when phenomenological constraints from electroweak precision observables, B physics, (g - 2) μ , mass-limits on sparticles from direct searches as well as, optionally, constraints from the observed dark matter density are taken into account. We derive possible new predictions for the GUT scale mass ratios and compare them with the phenomenologically allowed ranges. We find that new GUT scale predictions such as m μ /m s = 9/2 or 6 and y τ /y b = 3/2 or 2 are often favoured compared to the ubiquitous relations m μ /m s = 3 or y τ /y b = 1. The talk is based on the results obtained in Refs. [1, 2].

  11. The EIPeptiDi tool: enhancing peptide discovery in ICAT-based LC MS/MS experiments

    Directory of Open Access Journals (Sweden)

    Tradigo Giuseppe

    2007-07-01

    Full Text Available Abstract Background Isotope-coded affinity tags (ICAT is a method for quantitative proteomics based on differential isotopic labeling, sample digestion and mass spectrometry (MS. The method allows the identification and relative quantification of proteins present in two samples and consists of the following phases. First, cysteine residues are either labeled using the ICAT Light or ICAT Heavy reagent (having identical chemical properties but different masses. Then, after whole sample digestion, the labeled peptides are captured selectively using the biotin tag contained in both ICAT reagents. Finally, the simplified peptide mixture is analyzed by nanoscale liquid chromatography-tandem mass spectrometry (LC-MS/MS. Nevertheless, the ICAT LC-MS/MS method still suffers from insufficient sample-to-sample reproducibility on peptide identification. In particular, the number and the type of peptides identified in different experiments can vary considerably and, thus, the statistical (comparative analysis of sample sets is very challenging. Low information overlap at the peptide and, consequently, at the protein level, is very detrimental in situations where the number of samples to be analyzed is high. Results We designed a method for improving the data processing and peptide identification in sample sets subjected to ICAT labeling and LC-MS/MS analysis, based on cross validating MS/MS results. Such a method has been implemented in a tool, called EIPeptiDi, which boosts the ICAT data analysis software improving peptide identification throughout the input data set. Heavy/Light (H/L pairs quantified but not identified by the MS/MS routine, are assigned to peptide sequences identified in other samples, by using similarity criteria based on chromatographic retention time and Heavy/Light mass attributes. EIPeptiDi significantly improves the number of identified peptides per sample, proving that the proposed method has a considerable impact on the protein

  12. ICP-MS measurement of natural radioactivity at LNGS

    Science.gov (United States)

    Nisi, S.; Copia, L.; Dafinei, I.; di Vacri, M. L.

    2017-10-01

    Rare events search experiments, like those dedicated to the direct evidence of dark matter or neutrinoless double beta decay, are among the most exciting challenges of modern physics. The sensitivity of such experiments is driven by the background, which depends substantially on the radiopurity of the materials used for the experimental apparatus. Cutting edge measurement techniques are needed for a fast, sensitive and efficient screening of these materials and the certification of their production. Trace element measurements of high sensitivity and quick execution are mandatory also in other fields like tracing the geographical origin of food, temporal and geographical assignment of cultural heritage or monitoring environmental radioactivity. This work is an overview of the inorganic mass spectrometry facility available at Gran Sasso National Laboratory (LNGS) for radiopure material screening and is especially focused on its ICP-MS instrumentation. Analytical methods developed to achieve lowest detection limits in different types of matrix, like metals, polymers, crystals and composite materials, are also indicated. Detection limits of 10-18gg-1 for 226Ra, 10-14gg-1 for U and Th and 10-12gg-1 for K are attained through dedicated operation conditions of the instrumentation. Details are given on the results obtained for different experiments ongoing or under construction at LNGS.

  13. Product ion distributions for the reactions of NO+ with some physiologically significant aldehydes obtained using a SRI-TOF-MS instrument

    Czech Academy of Sciences Publication Activity Database

    Mochalski, P.; Unterkofler, K.; Španěl, Patrik; Smith, D.; Amann, A.

    2014-01-01

    Roč. 363, APR 2014 (2014), s. 23-31 ISSN 1387-3806 Institutional support: RVO:61388955 Keywords : aldehydes * SRI-TOF-MS * NO+ reactions Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.972, year: 2014

  14. Predictive Capability Maturity Model for computational modeling and simulation.

    Energy Technology Data Exchange (ETDEWEB)

    Oberkampf, William Louis; Trucano, Timothy Guy; Pilch, Martin M.

    2007-10-01

    The Predictive Capability Maturity Model (PCMM) is a new model that can be used to assess the level of maturity of computational modeling and simulation (M&S) efforts. The development of the model is based on both the authors experience and their analysis of similar investigations in the past. The perspective taken in this report is one of judging the usefulness of a predictive capability that relies on the numerical solution to partial differential equations to better inform and improve decision making. The review of past investigations, such as the Software Engineering Institute's Capability Maturity Model Integration and the National Aeronautics and Space Administration and Department of Defense Technology Readiness Levels, indicates that a more restricted, more interpretable method is needed to assess the maturity of an M&S effort. The PCMM addresses six contributing elements to M&S: (1) representation and geometric fidelity, (2) physics and material model fidelity, (3) code verification, (4) solution verification, (5) model validation, and (6) uncertainty quantification and sensitivity analysis. For each of these elements, attributes are identified that characterize four increasing levels of maturity. Importantly, the PCMM is a structured method for assessing the maturity of an M&S effort that is directed toward an engineering application of interest. The PCMM does not assess whether the M&S effort, the accuracy of the predictions, or the performance of the engineering system satisfies or does not satisfy specified application requirements.

  15. Evolution in miniaturized column liquid chromatography instrumentation and applications: An overview.

    Science.gov (United States)

    Nazario, Carlos E D; Silva, Meire R; Franco, Maraíssa S; Lanças, Fernando M

    2015-11-20

    The purpose of this article is to underline the miniaturized LC instrumental system and describe the evolution of commercially available systems by discussing their advantages and drawbacks. Nowadays, there are already many miniaturized LC systems available with a great variety of pump design, interface and detectors as well as efficient columns technologies and reduced connections devices. The solvent delivery systems are able to drive the mobile phase without flow splitters and promote gradient elution using either dual piston reciprocating or syringe-type pumps. The mass spectrometry as detection system is the most widely used detection system; among many alternative ionization sources direct-EI LC-MS is a promising alternative to APCI. In addition, capillary columns are now available showing many possibilities of stationary phases, inner diameters and hardware materials. This review provides a discussion about miniaturized LC demonstrating fundamentals and instrumentals' aspects of the commercially available miniaturized LC instrumental system mainly nano and micro LC formats. This review also covers the recent developments and trends in instrumentation, capillary and nano columns, and several applications of this very important and promising field. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Isotope ratio monitoring LC/MS (IRM-LC/MS): new applications

    International Nuclear Information System (INIS)

    Juchelka, D; Hilkert, A.; Krummen, M.

    2005-01-01

    With the introduction of compound specific isotope analysis by isotope ratio monitoring GC/ MS (IRM-GC/MS) the immediate demand for similar applications using HPLC was created. Many compounds of biological, medical, pharmaceutical and environmental interest are not volatile or too polar. Consequently, they cannot be directly analyzed by gas chromatography. In IRM-GC/MS the carrier is helium, which does not interfere with the essential combust ion step prior to isotope ratio mass spectrometry (IRMS). In opposite the LC mobile phase has inhibited a similar direct conversion up to now. All earlier IRM-LC/MS approaches were based on the removal of the liquid phase prior to combustion risking fractionation of the isotope ratios of the eluted compounds. To avoid such restrictions we developed a new continuous flow concept for the coupling of an HPLC system to the isotope ratio MS for 13 C/ 12C isotope ratio analysis. In the Finnigan LC IsoLink, the liquid phase is not removed from the sample prior to oxidation. The sample is oxidized still in the mobile phase followed by on-line separation of the CO 2 from the liquid phase and transfer into the isotope ratio MS. Therefore, this strategy is based on water and inorganic buffers as mobile phase. The new approach opens up a whole new world in the application of gas isotope ratio mass spectrometry. The 13 C/ 12 C ratio s of organic acids, amino acids, carbohydrates and nucleotides can now be measured. These components typically within a complex matrix are separated by liquid chromatography followed by on-line determination of the isotope ratios. The draw backs of using derivatization and off-line preparation procedures can now be over come. This new technique allow s studying biochemical cycles, running tracer experiments and determining the origin of components. Applications from different scientific areas such as biogeochemistry, molecular biology, and pharmacy as well as authenticity control o f foods will be presented

  17. Ms. Mentor Unmasked

    Science.gov (United States)

    Krebs, Paula

    2008-01-01

    This article presents an interview with Emily Toth, who writes the monthly "Ms. Mentor" academic advice column in the "Chronicle of Higher Education" and teaches in the English department at Louisiana State University, in Baton Rouge. She is the author of "Ms. Mentor's Impeccable Advice for Women in Academia" (1997), "Inside Peyton Place: The Life…

  18. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Your Practice Publications for Clinicians Publications for Your Patients MS Navigator Program Programs and Services for Your Patients Contact Us Clinical Fellows d Careers in MS ...

  19. Lung Cancer Serum Biomarker Discovery Using Label Free LC-MS/MS

    Science.gov (United States)

    Zeng, Xuemei; Hood, Brian L.; Zhao, Ting; Conrads, Thomas P.; Sun, Mai; Gopalakrishnan, Vanathi; Grover, Himanshu; Day, Roger S.; Weissfeld, Joel L.; Wilson, David O.; Siegfried, Jill M.; Bigbee, William L.

    2011-01-01

    Introduction Lung cancer remains the leading cause of cancer-related death with poor survival due to the late stage at which lung cancer is typically diagnosed. Given the clinical burden from lung cancer, and the relatively favorable survival associated with early stage lung cancer, biomarkers for early detection of lung cancer are of important potential clinical benefit. Methods We performed a global lung cancer serum biomarker discovery study using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in a set of pooled non-small cell lung cancer (NSCLC) case sera and matched controls. Immunoaffinity subtraction was used to deplete the top most abundant serum proteins; the remaining serum proteins were subjected to trypsin digestion and analyzed in triplicate by LC-MS/MS. The tandem mass spectrum data were searched against the human proteome database and the resultant spectral counting data were used to estimate the relative abundance of proteins across the case/control serum pools. The spectral counting derived abundances of some candidate biomarker proteins were confirmed with multiple reaction monitoring MS assays. Results A list of 49 differentially abundant candidate proteins was compiled by applying a negative binomial regression model to the spectral counting data (pbiomarkers with statistically significant differential abundance across the lung cancer case/control pools which, when validated, could improve lung cancer early detection. PMID:21304412

  20. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Treating MS Comprehensive Care Find an MS Care Provider Medications Managing Relapses Rehabilitation Complementary & Alternative Medicines For Clinicians Resources & Support Library & Education Programs Find Support Advanced Care ...

  1. Exploring the predictive value of the evoked potentials score in MS within an appropriate patient population: a hint for an early identification of benign MS?

    Directory of Open Access Journals (Sweden)

    Margaritella Nicolò

    2012-08-01

    Full Text Available Abstract Background The prognostic value of evoked potentials (EPs in multiple sclerosis (MS has not been fully established. The correlations between the Expanded Disability Status Scale (EDSS at First Neurological Evaluation (FNE and the duration of the disease, as well as between EDSS and EPs, have influenced the outcome of most previous studies. To overcome this confounding relations, we propose to test the prognostic value of EPs within an appropriate patient population which should be based on patients with low EDSS at FNE and short disease duration. Methods We retrospectively selected a sample of 143 early relapsing remitting MS (RRMS patients with an EDSS Results The Evoked Potentials score (EP score and the Time to EDSS 2.0 (TT2 were the best predictors of worsening in our sample (Odds Ratio 1.10 and 0.82 respectively, p=0.001. Low EP score (below 15–20 points, short TT2 (lower than 3–5 years and their interaction resulted to be the most useful for the identification of worsening patterns. Moreover, in patients with an EP score at FNE below 6 points and a TT2 greater than 3 years the probability of worsening was 10% after 4–5 years and rapidly decreased thereafter. Conclusions In an appropriate population of early RRMS patients, the EP score at FNE is a good predictor of disability at low values as well as in combination with a rapid buildup of disability. Interestingly, an EP score at FNE under the median together with a clinical stability lasting more than 3 years turned out to be a protective pattern. This finding may contribute to an early identification of benign patients, well before the term required to diagnose Benign MS (BMS.

  2. Progressive-Relapsing MS (PRMS)

    Science.gov (United States)

    ... Is MS? Types of MS Share this page Facebook Twitter Email ... multiple sclerosis (PRMS) was described in the 1996 disease-course definitions as — steadily worsening neurologic function from the beginning ...

  3. EPA CRL MS014: Analysis of Aldicarb, Bromadiolone, Carbofuran, Oxamyl and Methomyl in Water by Multiple Reaction Monitoring Liquid Chromatography / Tandem Mass Spectrometry (LC/MS/MS)

    Science.gov (United States)

    Method MS014 describes procedures for solvent extraction of aldicarb, bromadiolone, carbofuran, oxamyl and methomyl from water samples, followed by analysis using liquid chromatography tandem mass spectrometry (LC-MS-MS).

  4. Preventive maintenance instrumentation results in Spanish nuclear power plants

    International Nuclear Information System (INIS)

    Palomo Anaya, M. Jose; Verdu Martin, Gumersindo; Arnaldos Gonzalvez, Adoracion; Nieva, Marcelino Curiel

    2011-01-01

    This paper is a recompilation of the most significant results in relation to the researching in Preventive and Predictive Maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and The Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the Power Plants Control and Instrumentation Department technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the aim to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish Nuclear Power Plants each of them shall give a significant contribution to problem resolution and power plant performance: Fluctuations in sensor lines (case 1), Air presence in feed water lines (case 2), Root valve partially closed (case 3), Sensor malfunctions (case 4), Electrical source malfunctions (case 5), RTD malfunctions (case 6) and LPRM malfunctions (case 7). (author)

  5. Preventive maintenance instrumentation results in Spanish nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Palomo Anaya, M. Jose; Verdu Martin, Gumersindo, E-mail: mpalomo@iqn.upv.es, E-mail: gverdu@iqn.upv.es [ISIRYM Universidad Politecnica de Valencia, Valencia (Spain); Arnaldos Gonzalvez, Adoracion, E-mail: a.arnaldos@titaniast.com [TITANIA Servicios Tecnologicos SL, Valencia (Spain); Nieva, Marcelino Curiel, E-mail: m.curiel@lainsa.com [Logistica y Acondicionamientos Industriales SAU (LAINSA), Valencia (Spain)

    2011-07-01

    This paper is a recompilation of the most significant results in relation to the researching in Preventive and Predictive Maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and The Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the Power Plants Control and Instrumentation Department technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the aim to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish Nuclear Power Plants each of them shall give a significant contribution to problem resolution and power plant performance: Fluctuations in sensor lines (case 1), Air presence in feed water lines (case 2), Root valve partially closed (case 3), Sensor malfunctions (case 4), Electrical source malfunctions (case 5), RTD malfunctions (case 6) and LPRM malfunctions (case 7). (author)

  6. Application of LC–MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids

    Directory of Open Access Journals (Sweden)

    Jamshed Haneef

    2013-10-01

    Full Text Available Liquid chromatography tandem mass chromatography (LC–MS/MS is an important hyphenated technique for quantitative analysis of drugs in biological fluids. Because of high sensitivity and selectivity, LC–MS/MS has been used for pharmacokinetic studies, metabolites identification in the plasma and urine. This manuscript gives comprehensive analytical review, focusing on chromatographic separation approaches (column packing materials, column length and mobile phase as well as different acquisition modes (SIM, MRM for quantitative analysis of glucocorticoids and stimulants. This review is not meant to be exhaustive but rather to provide a general overview for detection and confirmation of target drugs using LC–MS/MS and thus useful in the doping analysis, toxicological studies as well as in pharmaceutical analysis. Keywords: LC–MS/MS, Ionization techniques, Glucocorticoids, Stimulants, Hyphenated techniques, Biological fluid

  7. Impact of sampling interval in training data acquisition on intrafractional predictive accuracy of indirect dynamic tumor-tracking radiotherapy.

    Science.gov (United States)

    Mukumoto, Nobutaka; Nakamura, Mitsuhiro; Akimoto, Mami; Miyabe, Yuki; Yokota, Kenji; Matsuo, Yukinori; Mizowaki, Takashi; Hiraoka, Masahiro

    2017-08-01

    To explore the effect of sampling interval of training data acquisition on the intrafractional prediction error of surrogate signal-based dynamic tumor-tracking using a gimbal-mounted linac. Twenty pairs of respiratory motions were acquired from 20 patients (ten lung, five liver, and five pancreatic cancer patients) who underwent dynamic tumor-tracking with the Vero4DRT. First, respiratory motions were acquired as training data for an initial construction of the prediction model before the irradiation. Next, additional respiratory motions were acquired for an update of the prediction model due to the change of the respiratory pattern during the irradiation. The time elapsed prior to the second acquisition of the respiratory motion was 12.6 ± 3.1 min. A four-axis moving phantom reproduced patients' three dimensional (3D) target motions and one dimensional surrogate motions. To predict the future internal target motion from the external surrogate motion, prediction models were constructed by minimizing residual prediction errors for training data acquired at 80 and 320 ms sampling intervals for 20 s, and at 500, 1,000, and 2,000 ms sampling intervals for 60 s using orthogonal kV x-ray imaging systems. The accuracies of prediction models trained with various sampling intervals were estimated based on training data with each sampling interval during the training process. The intrafractional prediction errors for various prediction models were then calculated on intrafractional monitoring images taken for 30 s at the constant sampling interval of a 500 ms fairly to evaluate the prediction accuracy for the same motion pattern. In addition, the first respiratory motion was used for the training and the second respiratory motion was used for the evaluation of the intrafractional prediction errors for the changed respiratory motion to evaluate the robustness of the prediction models. The training error of the prediction model was 1.7 ± 0.7 mm in 3D for all sampling

  8. Airborne measurements of reactive organic trace gases in the atmosphere - with a focus on PTR-MS measurements onboard NASA's flying laboratories

    Science.gov (United States)

    Wisthaler, Armin; Mikoviny, Tomas; Müller, Markus; Schiller, Sven Arne; Feil, Stefan; Hanel, Gernot; Jordan, Alfons; Mutschlechner, Paul; Crawford, James H.; Singh, Hanwant B.; Millet, Dylan

    2017-04-01

    Reactive organic gases (ROGs) play an important role in atmospheric chemistry as they affect the rates of ozone production, particle formation and growth, and oxidant consumption. Measurements of ROGs are analytically challenging because of their large variety and low concentrations in the Earth's atmosphere, and because they are easily affected by measurement artefacts. On aircraft, ROGs are typically measured by canister sampling followed by off-line analysis in the laboratory, fast online gas chromatography or online chemical ionization mass spectrometry. In this work, we will briefly sum up the state-of-the-art in this field before focusing on proton-transfer-reaction mass spectrometry (PTR-MS) and its deployment onboard NASA's airborne science laboratories. We will show how airborne PTR-MS was successfully used in NASA missions for characterizing emissions of ROGs from point sources, for following the photochemical evolution of ROGs in a biomass burning plume, for determining biosphere-atmosphere fluxes of selected ROGs and for validating satellite data. We will also present the airborne PTR-MS instrument in its most recent evolution which includes a radiofrequency ion funnel and ion guide combined with a compact time-of-flight mass spectrometer and discuss its superior performance characteristics. The development of the airborne PTR-MS instrument was supported by the Austrian Federal Ministry for Transport, Innovation and Technology (bmvit) through the Austrian Space Applications Programme (ASAP) of the Austrian Research Promotion Agency (FFG) (grants #833451, #847967). This work was also partly supported by NASA under grant #NNX14AP89G.

  9. MS Windows domēna darbstacijas migrācijas iespējas no MS Windows XP uz MS Windows 7.

    OpenAIRE

    Zariņš, Valdis

    2009-01-01

    Kvalifikācijas darbā tiek aprakstītas MS Windows domēna darbstacijas migrācijas iespējas no MS Windows XP uz MS Windows 7, kā servera operētājsistēmas izmantojot tādus Microsoft produktus, kā Microsoft Windows Server 2003 un Microsoft Windows Server 2008. Kvalifikācijas darba teorētiskaja daļā tiek apskatīti Microsoft Windows 7 priekšrocības un uzlabojumus gan no darbstacijas lietotāja , gan no darbstacijas administratora puses. Ir aprakstītas Microsoft Windows Server 2008 jauninājumu ie...

  10. Reliable LC-MS quantitative glycomics using iGlycoMab stable isotope labeled glycans as internal standards.

    Science.gov (United States)

    Zhou, Shiyue; Tello, Nadia; Harvey, Alex; Boyes, Barry; Orlando, Ron; Mechref, Yehia

    2016-06-01

    Glycans have numerous functions in various biological processes and participate in the progress of diseases. Reliable quantitative glycomic profiling techniques could contribute to the understanding of the biological functions of glycans, and lead to the discovery of potential glycan biomarkers for diseases. Although LC-MS is a powerful analytical tool for quantitative glycomics, the variation of ionization efficiency and MS intensity bias are influencing quantitation reliability. Internal standards can be utilized for glycomic quantitation by MS-based methods to reduce variability. In this study, we used stable isotope labeled IgG2b monoclonal antibody, iGlycoMab, as an internal standard to reduce potential for errors and to reduce variabililty due to sample digestion, derivatization, and fluctuation of nanoESI efficiency in the LC-MS analysis of permethylated N-glycans released from model glycoproteins, human blood serum, and breast cancer cell line. We observed an unanticipated degradation of isotope labeled glycans, tracked a source of such degradation, and optimized a sample preparation protocol to minimize degradation of the internal standard glycans. All results indicated the effectiveness of using iGlycoMab to minimize errors originating from sample handling and instruments. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. A simpler method of preprocessing MALDI-TOF MS data for differential biomarker analysis: stem cell and melanoma cancer studies

    Directory of Open Access Journals (Sweden)

    Tong Dong L

    2011-09-01

    Full Text Available Abstract Introduction Raw spectral data from matrix-assisted laser desorption/ionisation time-of-flight (MALDI-TOF with MS profiling techniques usually contains complex information not readily providing biological insight into disease. The association of identified features within raw data to a known peptide is extremely difficult. Data preprocessing to remove uncertainty characteristics in the data is normally required before performing any further analysis. This study proposes an alternative yet simple solution to preprocess raw MALDI-TOF-MS data for identification of candidate marker ions. Two in-house MALDI-TOF-MS data sets from two different sample sources (melanoma serum and cord blood plasma are used in our study. Method Raw MS spectral profiles were preprocessed using the proposed approach to identify peak regions in the spectra. The preprocessed data was then analysed using bespoke machine learning algorithms for data reduction and ion selection. Using the selected ions, an ANN-based predictive model was constructed to examine the predictive power of these ions for classification. Results Our model identified 10 candidate marker ions for both data sets. These ion panels achieved over 90% classification accuracy on blind validation data. Receiver operating characteristics analysis was performed and the area under the curve for melanoma and cord blood classifiers was 0.991 and 0.986, respectively. Conclusion The results suggest that our data preprocessing technique removes unwanted characteristics of the raw data, while preserving the predictive components of the data. Ion identification analysis can be carried out using MALDI-TOF-MS data with the proposed data preprocessing technique coupled with bespoke algorithms for data reduction and ion selection.

  12. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Contact Us Newly Diagnosed If you or somone close to you has recently been diagnosed, access our MS information and resources. Start ... Room MS Prevalence Charitable Ratings Corporate Support Helpful Links ...

  13. MS in Your Relationships

    Science.gov (United States)

    ... MS Relationships Share this page Facebook Twitter Email Relationships MS poses additional challenges, but it also enriches ... when it is not. Keeping balance in your relationship When one person in a couple is affected ...

  14. Single-cell analysis by ICP-MS/MS as a fast tool for cellular bioavailability studies of arsenite.

    Science.gov (United States)

    Meyer, S; López-Serrano, A; Mitze, H; Jakubowski, N; Schwerdtle, T

    2018-01-24

    Single-cell inductively coupled plasma mass spectrometry (SC-ICP-MS) has become a powerful and fast tool to evaluate the elemental composition at a single-cell level. In this study, the cellular bioavailability of arsenite (incubation of 25 and 50 μM for 0-48 h) has been successfully assessed by SC-ICP-MS/MS for the first time directly after re-suspending the cells in water. This procedure avoids the normally arising cell membrane permeabilization caused by cell fixation methods (e.g. methanol fixation). The reliability and feasibility of this SC-ICP-MS/MS approach with a limit of detection of 0.35 fg per cell was validated by conventional bulk ICP-MS/MS analysis after cell digestion and parallel measurement of sulfur and phosphorus.

  15. Forensic Drug Identification, Confirmation, and Quantification Using Fully Integrated Gas Chromatography with Fourier Transform Infrared and Mass Spectrometric Detection (GC-FT-IR-MS).

    Science.gov (United States)

    Lanzarotta, Adam; Lorenz, Lisa; Voelker, Sarah; Falconer, Travis M; Batson, JaCinta S

    2018-05-01

    This manuscript is a continuation of a recent study that described the use of fully integrated gas chromatography with direct deposition Fourier transform infrared detection and mass spectrometric detection (GC-FT-IR-MS) to identify and confirm the presence of sibutramine and AB-FUBINACA. The purpose of the current study was to employ the GC-FT-IR portion of the same instrument to quantify these compounds, thereby demonstrating the ability to identify, confirm, and quantify drug substances using a single GC-FT-IR-MS unit. The performance of the instrument was evaluated by comparing quantitative analytical figures of merit to those measured using an established, widely employed method for quantifying drug substances, high performance liquid chromatography with ultraviolet detection (HPLC-UV). The results demonstrated that GC-FT-IR was outperformed by HPLC-UV with regard to sensitivity, precision, and linear dynamic range (LDR). However, sibutramine and AB-FUBINACA concentrations measured using GC-FT-IR were not significantly different at the 95% confidence interval compared to those measured using HPLC-UV, which demonstrates promise for using GC-FT-IR as a semi-quantitative tool at the very least. The most significant advantage of GC-FT-IR compared to HPLC-UV is selectivity; a higher level of confidence regarding the identity of the analyte being quantified is achieved using GC-FT-IR. Additional advantages of using a single GC-FT-IR-MS instrument for identification, confirmation, and quantification are efficiency, increased sample throughput, decreased consumption of laboratory resources (solvents, chemicals, consumables, etc.), and thus cost.

  16. An impulse-driven liquid-droplet deposition interface for combining LC with MALDI MS and MS/MS.

    Science.gov (United States)

    Young, J Bryce; Li, Liang

    2006-03-01

    A simple and robust impulse-driven droplet deposition system was developed for off-line liquid chromatography matrix-assisted laser desorption ionization mass spectrometry (LC-MALDI MS). The system uses a solenoid operated with a pulsed voltage power supply to generate impulses that dislodge the hanging droplets from the LC outlet directly to a MALDI plate via a momentum transfer process. There is no contact between the LC outlet and the collection surface. The system is compatible with solvents of varying polarity and viscosity, and accommodates the use of hydrophobic and hydrophilic MALDI matrices. MALDI spots are produced on-line with the separation, and do not require further processing before MS analysis. It is shown that high quality MALDI spectra from 5 fmol of pyro-Glu-fibrinopeptide deposition after LC separation could be obtained using the device, indicating that there was no sample loss in the interface. To demonstrate the analytical performance of the system as a proteome analysis tool, a range of BSA digest concentrations covering about 3 orders of magnitude, from 5 fmol to 1 pmol, were analyzed by LC-MALDI quadrupole time-of-flight MS, yielding 6 and 57% amino acid sequence coverage, respectively. In addition, a complex protein mixture of an E. coli cell extract was tryptically digested and analyzed by LC-MALDI MS, resulting in the detection of a total of 409 unique peptides from 100 fractions of 15-s intervals.

  17. Analysis of Ba{sub x}Sr{sub y}TiO{sub 3} perovskite layers. II. Development of analytical method for the determination of the stoichiometry and trace impurities by ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, S.F. [Forschungszentrum Juelich GmbH (Germany). Zentralabteilung fuer Chemische Analysen]|[Radiation Physics and Chemistry Problems Inst., Minsk (Belarus); Becker, J.S. [Forschungszentrum Juelich GmbH (Germany). Zentralabteilung fuer Chemische Analysen

    2000-11-01

    Determination of stoichiometry in semiconducting and non-conducting thin layers is of importance for the study of growth mechanisms and for the control of defects during their development and production. An analytical procedure for inductively coupled plasma mass spectrometry (ICP-MS) was developed using different ICP-MS instruments [one double-focusing sector field ICP-MS (DF-ICP-MS) and two quadrupole ICP-MS without and with hexapole collision cell (ICP-QMS and HEX-ICP-QMS, respectively)] for the determination of stoichiometry and trace impurities in thin Ba{sub x}Sr{sub y}TiO{sub 3} (BST) perovskite layers on silicon substrates after dissolution of layer. Maximum sensitivity, lowest detection limits and best precision was achieved in DF-ICP-MS. ICP-QMS with hexapole collision cell yielded better sensitivity and lower limits of detection in comparison to conventional quadrupole ICP-MS. (orig.)

  18. SWATH Mass Spectrometry Performance Using Extended Peptide MS/MS Assay Libraries*

    Science.gov (United States)

    Wu, Jemma X.; Song, Xiaomin; Pascovici, Dana; Zaw, Thiri; Care, Natasha; Krisp, Christoph; Molloy, Mark P.

    2016-01-01

    The use of data-independent acquisition methods such as SWATH for mass spectrometry based proteomics is usually performed with peptide MS/MS assay libraries which enable identification and quantitation of peptide peak areas. Reference assay libraries can be generated locally through information dependent acquisition, or obtained from community data repositories for commonly studied organisms. However, there have been no studies performed to systematically evaluate how locally generated or repository-based assay libraries affect SWATH performance for proteomic studies. To undertake this analysis, we developed a software workflow, SwathXtend, which generates extended peptide assay libraries by integration with a local seed library and delivers statistical analysis of SWATH-quantitative comparisons. We designed test samples using peptides from a yeast extract spiked into peptides from human K562 cell lysates at three different ratios to simulate protein abundance change comparisons. SWATH-MS performance was assessed using local and external assay libraries of varying complexities and proteome compositions. These experiments demonstrated that local seed libraries integrated with external assay libraries achieve better performance than local assay libraries alone, in terms of the number of identified peptides and proteins and the specificity to detect differentially abundant proteins. Our findings show that the performance of extended assay libraries is influenced by the MS/MS feature similarity of the seed and external libraries, while statistical analysis using multiple testing corrections increases the statistical rigor needed when searching against large extended assay libraries. PMID:27161445

  19. LC-MS/MS Peptide Mapping with Automated Data Processing for Routine Profiling of N-Glycans in Immunoglobulins

    Science.gov (United States)

    Shah, Bhavana; Jiang, Xinzhao Grace; Chen, Louise; Zhang, Zhongqi

    2014-06-01

    Protein N-Glycan analysis is traditionally performed by high pH anion exchange chromatography (HPAEC), reversed phase liquid chromatography (RPLC), or hydrophilic interaction liquid chromatography (HILIC) on fluorescence-labeled glycans enzymatically released from the glycoprotein. These methods require time-consuming sample preparations and do not provide site-specific glycosylation information. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) peptide mapping is frequently used for protein structural characterization and, as a bonus, can potentially provide glycan profile on each individual glycosylation site. In this work, a recently developed glycopeptide fragmentation model was used for automated identification, based on their MS/MS, of N-glycopeptides from proteolytic digestion of monoclonal antibodies (mAbs). Experimental conditions were optimized to achieve accurate profiling of glycoforms. Glycan profiles obtained from LC-MS/MS peptide mapping were compared with those obtained from HPAEC, RPLC, and HILIC analyses of released glycans for several mAb molecules. Accuracy, reproducibility, and linearity of the LC-MS/MS peptide mapping method for glycan profiling were evaluated. The LC-MS/MS peptide mapping method with fully automated data analysis requires less sample preparation, provides site-specific information, and may serve as an alternative method for routine profiling of N-glycans on immunoglobulins as well as other glycoproteins with simple N-glycans.

  20. Risk factors for cesarean section and instrumental vaginal delivery after successful external cephalic version.

    Science.gov (United States)

    de Hundt, Marcella; Vlemmix, Floortje; Bais, Joke M J; de Groot, Christianne J; Mol, Ben Willem; Kok, Marjolein

    2016-01-01

    Aim of this article is to examine if we could identify factors that predict cesarean section and instrumental vaginal delivery in women who had a successful external cephalic version. We used data from a previous randomized trial among 25 hospitals and their referring midwife practices in the Netherlands. With the data of this trial, we performed a cohort study among women attempting vaginal delivery after successful ECV. We evaluated whether maternal age, gestational age, parity, time interval between ECV and delivery, birth weight, neonatal gender, and induction of labor were predictive for a vaginal delivery on one hand or a CS or instrumental vaginal delivery on the other hand. Unadjusted and adjusted odds ratios were calculated with univariate and multivariate logistic regression analysis. Among 301 women who attempted vaginal delivery after a successful external cephalic version attempt, the cesarean section rate was 13% and the instrumental vaginal delivery rate 6%, resulting in a combined instrumental delivery rate of 19%. Nulliparity increased the risk of cesarean section (OR 2.7 (95% CI 1.2-6.1)) and instrumental delivery (OR 4.2 (95% CI 2.1-8.6)). Maternal age, gestational age at delivery, time interval between external cephalic version and delivery, birth weight and neonatal gender did not contribute to the prediction of failed spontaneous vaginal delivery. In our cohort of 301 women with a successful external cephalic version, nulliparity was the only one of seven factors that predicted the risk for cesarean section and instrumental vaginal delivery.

  1. Investigation of enrofloxacin residues in broiler tissues using ELISA and LC-MS/MS.

    Science.gov (United States)

    Panzenhagen, Pedro Henrique N; Aguiar, Waldemir S; Gouvêa, Raquel; de Oliveira, Andréa M G; Barreto, Fabiano; Pereira, Virgínia L A; Aquino, Maria Helena C

    2016-01-01

    This study investigated the efficiency of an enrofloxacin ELISA test kit to detect the presence of enrofloxacin residues in broiler tissues compared with LC-MS/MS. Broiler tissues from 72 samples consisting of 60 breast muscle, six pools of livers (500 g each) and six pools of kidneys (500 g each) were obtained from six different slaughterhouses. Breast muscle from 10 carcasses and pools of livers and kidneys from approximately 200 carcasses of the same flock were collected from each slaughterhouse. ELISA and HPLC were used to identify and quantify the contamination of the samples with enrofloxacin. A total of 72% of the analysed samples contained enrofloxacin residues detected by the ELISA and 22.2% were detected by LC-MS/MS. The mean values of enrofloxacin contamination found in chicken breast by ELISA and HPLC were 8.63 and 12.25 μg kg(-1), respectively. None of the samples exceeded the maximum limit of 100 μg kg(-1) by both methods set by the European Union as well as the Brazilian Agriculture Ministry. All positive samples for enrofloxacin residues detected by LC-MS/MS were also positive by ELISA. These data confirm the efficiency of the ELISA test, and suggest its use as a screening method for enrofloxacin residues in poultry tissues due to its quick results, low price and ease of applicability.

  2. Relationship between plasma and salivary melatonin and cortisol investigated by LC-MS/MS.

    Science.gov (United States)

    van Faassen, Martijn; Bischoff, Rainer; Kema, Ido P

    2017-08-28

    Disturbance of the circadian rhythm has been associated with disease states, such as metabolic disorders, depression and cancer. Quantification of the circadian markers such as melatonin and cortisol critically depend on reliable and reproducible analytical methods. Previously, melatonin and cortisol were primarily analyzed separately, mainly using immunoassays. Here we describe the validation and application of a high-throughput liquid chromatography in combination with mass spectrometry (LC-MS/MS) method for the combined analysis of melatonin and cortisol in plasma and saliva. The LC-MS/MS method was validated according to international validation guidelines. We used this method to analyze total plasma, free plasma (as obtained by equilibrium dialysis) and saliva melatonin and cortisol in healthy adults. Validation results for plasma and saliva melatonin and cortisol were well within the international validation criteria. We observed no difference between saliva collected by passive drooling or Salivette. Moreover, we noted a significant difference in saliva vs. free plasma melatonin. We observed on average 36% (95% CI: 4%-60%) higher salivary melatonin levels in comparison to free plasma melatonin, suggestive of local production of melatonin in the salivary glands. The novel outcome of this study is probably due to the high precision of our LC-MS/MS assay. These outcomes illustrate the added value of accurate and sensitive mass spectrometry based methods for the quantification of neuroendocrine biomarkers.

  3. Analytical methods for multiresidue determination of sulfonamides and trimethoprim in meat and ground water samples by CE-MS and CE-MS/MS.

    Science.gov (United States)

    Soto-Chinchilla, Jorge J; García-Campaña, Ana M; Gámiz-Gracia, Laura

    2007-11-01

    This paper presents two methods based on CZE-MS detection and CZE-MS/MS detection developed for the multiresidue determination of ten sulfonamides (sulfapyridine, sulfadoxin, sulfamethazine, sulfadimethoxine, sulfameter, sulfamerazine, sulfachlorpyridazine, sulfadiazine, sulfamethoxazole, and sulfamethizole) and a potentiator, trimethoprim (TMP), whose contents are regulated by the EU Council Regulation no. 2377/90 in animal edible tissues. Experimental designs were employed to optimize the electrospray conditions. MS/MS experiments using an IT as analyzer operating in multiple reaction monitoring (MRM) mode were carried out to achieve the minimum number of points according to the 2002/657/EC European Decision for unambiguous identification. The proposed procedures have been compared in terms of the performance characteristics and trueness. The limits of detection and quantification were in all cases lower than the maximum residue limits legislated for these compounds and the recoveries were satisfactory, being possible the application for their monitoring in foodstuff of animal origin and in environmental samples, allowing the determination of sulfonamides and TMP residues in meat and in superficial water in the low microg/L range.

  4. From Qualitative Data to Instrument Development: The Women's Breast Conflict Scale

    Science.gov (United States)

    Thomas, Eileen

    2011-01-01

    The purpose of this article is to describe the initial development of the Women's Breast Conflict Scale, a predictive instrument designed to identify women who may be least likely to follow recommended mammography screening guidelines. This new instrument incorporates self/body image, teasing, family norms and values, and societal/media…

  5. Cross-validated stable-isotope dilution GC-MS and LC-MS/MS assays for monoacylglycerol lipase (MAGL) activity by measuring arachidonic acid released from the endocannabinoid 2-arachidonoyl glycerol.

    Science.gov (United States)

    Kayacelebi, Arslan Arinc; Schauerte, Celina; Kling, Katharina; Herbers, Jan; Beckmann, Bibiana; Engeli, Stefan; Jordan, Jens; Zoerner, Alexander A; Tsikas, Dimitrios

    2017-03-15

    2-Arachidonoyl glycerol (2AG) is an endocannabinoid that activates cannabinoid (CB) receptors CB1 and CB2. Monoacylglycerol lipase (MAGL) inactivates 2AG through hydrolysis to arachidonic acid (AA) and glycerol, thus modulating the activity at CB receptors. In the brain, AA released from 2AG by the action of MAGL serves as a substrate for cyclooxygenases which produce pro-inflammatory prostaglandins. Here we report stable-isotope GC-MS and LC-MS/MS assays for the reliable measurement of MAGL activity. The assays utilize deuterium-labeled 2AG (d 8 -2AG; 10μM) as the MAGL substrate and measure deuterium-labeled AA (d 8 -AA; range 0-1μM) as the MAGL product. Unlabelled AA (d 0 -AA, 1μM) serves as the internal standard. d 8 -AA and d 0 -AA are extracted from the aqueous buffered incubation mixtures by ethyl acetate. Upon solvent evaporation the residue is reconstituted in the mobile phase prior to LC-MS/MS analysis or in anhydrous acetonitrile for GC-MS analysis. LC-MS/MS analysis is performed in the negative electrospray ionization mode by selected-reaction monitoring the mass transitions [M-H] - →[M-H - CO 2 ] - , i.e., m/z 311→m/z 267 for d 8 -AA and m/z 303→m/z 259 for d 0 -AA. Prior to GC-MS analysis d 8 -AA and d 0 -AA were converted to their pentafluorobenzyl (PFB) esters by means of PFB-Br. GC-MS analysis is performed in the electron-capture negative-ion chemical ionization mode by selected-ion monitoring the ions [M-PFB] - , i.e., m/z 311 for d 8 -AA and m/z 303 for d 0 -AA. The GC-MS and LC-MS/MS assays were cross-validated. Linear regression analysis between the concentration (range, 0-1μM) of d 8 -AA measured by LC-MS/MS (y) and that by GC-MS (x) revealed a straight line (r 2 =0.9848) with the regression equation y=0.003+0.898x, indicating a good agreement. In dog liver, we detected MAGL activity that was inhibitable by the MAGL inhibitor JZL-184. Exogenous eicosatetraynoic acid is suitable as internal standard for the quantitative determination

  6. The potential use of complex derivatization procedures in comprehensive HPLC-MS/MS detection of anabolic steroids.

    Science.gov (United States)

    Baranov, Pavel A; Appolonova, Svetlana A; Rodchenkov, Grigory M

    2010-10-01

    The use of two separate derivatization procedures with the formation of oxime (hydroxyl ammonium pretreatment) and picolinoyl (mixed anhydride method) derivates of anabolic steroids following HPLC-MS/MS analysis was proposed. The main product ions of obtained derivatives for 21 anabolic steroids were evaluated and fragmentation pathways were compared.The analysis of MS/MS spectra for underivatized steroids versus oxime or picolinoyl derivatives showed that in case of analytes containing conjugated double bonds in sterane core all of the observed MS/MS spectra contained abundant product ions of diagnostic value. The implementation of derivatization procedures to such compounds is useful for upgrading sensitivity or selectivity of the evaluated method. On the other hand, MS/MS spectra of underivatized and oxime analytes without conjugated double bonds in sterane core produce spectra with large amounts of low abundant product ions. Picolinoyl derivatives formation leads to highly specific spectra with product ions of diagnostic value coupled with sensitive and selective analysis at the same time. The intra- and inter-group comparison analysis revealed that fragmentation pathways for underivatized steroids and correspondent oxime derivatives are similar.The obtained oxime and picolinoyl derivatives provided 10-15 times higher ESI response in the HPLC-ESI-MS-selected reaction monitoring (SRM) when compared to those of underivatized molecules in positive HPLC-ESI-MS mode.Due to the laborious sample preparation we suggest to use the performed strategy for confirmation analysis purposes, metabolic studies or while the identification of new steroids or steroid-like substances. Copyright © 2010 John Wiley & Sons, Ltd.

  7. ESI MS/MS Study of Calix[4]arene Derivatives and their Metal Complexes

    OpenAIRE

    Benković, Tomislav; Tomišić, Vladislav; Frkanec, Leo; Galić, Nives

    2012-01-01

    The peptidocalixarenes 1–3 bearing tryptophan, phenylglycine and leucil units at the lower rim and their complexes with alkali-metal (Li+, Na+, K+, Rb+, Cs+) and selected lanthanide cations (La3+, Ce3+, Eu3+, Yb3+) were analyzed by ESI MS. The influences of the solvent (acetonitrile, methanol, addition of formic acid or sodium acetate) and the calixarene:cation molar ratio on signal intensities were investigated. Comprehensive MS/MS analyses were performed of all singly and doubly charged ion...

  8. A Low-Cost, Simplified Platform of Interchangeable, Ambient Ionization Sources for Rapid, Forensic Evidence Screening on Portable Mass Spectrometric Instrumentation

    Directory of Open Access Journals (Sweden)

    Patrick W. Fedick

    2018-03-01

    Full Text Available Portable mass spectrometers (MS are becoming more prevalent due to improved instrumentation, commercialization, and the robustness of new ionization methodologies. To increase utility towards diverse field-based applications, there is an inherent need for rugged ionization source platforms that are simple, yet robust towards analytical scenarios that may arise. Ambient ionization methodologies have evolved to target specific real-world problems and fulfill requirements of the analysis at hand. Ambient ionization techniques continue to advance towards higher performance, with specific sources showing variable proficiency depending on application area. To realize the full potential and applicability of ambient ionization methods, a selection of sources may be more prudent, showing a need for a low-cost, flexible ionization source platform. This manuscript describes a centralized system that was developed for portable MS systems that incorporates modular, rapidly-interchangeable ionization sources comprised of low-cost, commercially-available parts. Herein, design considerations are reported for a suite of ambient ionization sources that can be crafted with minimal machining or customization. Representative spectral data is included to demonstrate applicability towards field processing of forensic evidence. While this platform is demonstrated on portable instrumentation, retrofitting to lab-scale MS systems is anticipated.

  9. Recovering protein-protein and domain-domain interactions from aggregation of IP-MS proteomics of coregulator complexes.

    Directory of Open Access Journals (Sweden)

    Amin R Mazloom

    2011-12-01

    Full Text Available Coregulator proteins (CoRegs are part of multi-protein complexes that transiently assemble with transcription factors and chromatin modifiers to regulate gene expression. In this study we analyzed data from 3,290 immuno-precipitations (IP followed by mass spectrometry (MS applied to human cell lines aimed at identifying CoRegs complexes. Using the semi-quantitative spectral counts, we scored binary protein-protein and domain-domain associations with several equations. Unlike previous applications, our methods scored prey-prey protein-protein interactions regardless of the baits used. We also predicted domain-domain interactions underlying predicted protein-protein interactions. The quality of predicted protein-protein and domain-domain interactions was evaluated using known binary interactions from the literature, whereas one protein-protein interaction, between STRN and CTTNBP2NL, was validated experimentally; and one domain-domain interaction, between the HEAT domain of PPP2R1A and the Pkinase domain of STK25, was validated using molecular docking simulations. The scoring schemes presented here recovered known, and predicted many new, complexes, protein-protein, and domain-domain interactions. The networks that resulted from the predictions are provided as a web-based interactive application at http://maayanlab.net/HT-IP-MS-2-PPI-DDI/.

  10. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Programs and Events Living Well with MS Diet, Exercise & Healthy Behaviors Emotional Well-Being Spiritual Well-Being ... Events d Living Well with MS d Diet, Exercise & Healthy Behaviors Diet & Nutrition Exercise Heat & Temperature Sensitivity ...

  11. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Events Living Well with MS Diet, Exercise & Healthy Behaviors Emotional Well-Being Spiritual Well-Being Cognitive Health ... Living Well with MS d Diet, Exercise & Healthy Behaviors Diet & Nutrition Exercise Heat & Temperature Sensitivity Sleep Vaccinations ...

  12. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Rule Out For Clinicians Treating MS Comprehensive Care Find an MS Care Provider Medications Managing Relapses Rehabilitation ... Medicines For Clinicians Resources & Support Library & Education Programs Find Support Advanced Care Needs Resources for Specific Populations ...

  13. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... bowel and bladder problems, and problems with cognition (learning and memory or information processing). People with progressive ... More The National MS Society is Here to Help Need More Information? We Are Here Our MS ...

  14. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... of Programs and Events Living Well with MS Diet, Exercise & Healthy Behaviors Emotional Well-Being Spiritual Well- ... and Events d Living Well with MS d Diet, Exercise & Healthy Behaviors Diet & Nutrition Exercise Heat & Temperature ...

  15. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... d Spiritual Well-Being Building Spirituality into Your Life d Cognitive Health d Work, Home & Leisure Employment ... Partnership Opportunities d Personal Stories Ambassadors & Familiar Faces Life with MS Givers Shakers Families with MS Seekers ...

  16. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Brochure Working with MS (.pdf) Download Brochure Taming Stress (.pdf) Download Brochure Multiple Sclerosis and Your Emotions (. ... For Professionals Researchers Physicians Nurses Rehabilitation Professionals Mental Health Professionals Health and Wellness Professionals What Is MS? ...

  17. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Online d Give in Honor or Memory d Workplace Giving d Employer Matching Gifts d Gifts of ... Living with MS (.pdf) Download Brochure Focus on Employment (.pdf) Download Brochure Working with MS (.pdf) Download ...

  18. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Life d Cognitive Health d Work, Home & Leisure Employment Insurance & Financial Information Staying Mobile Reclaiming Control Accessibility ... Living with MS (.pdf) Download Brochure Focus on Employment (.pdf) Download Brochure Working with MS (.pdf) Download ...

  19. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... working effectively. How does RRMS differ from progressive types of MS? While RRMS is defined by attacks ... forms of MS involve much less of this type of inflammation. People with RRMS tend to have ...

  20. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... attacks of inflammation (relapses) in the CNS, progressive forms of MS involve much less of this type ... and memory or information processing). People with progressive forms of MS are more likely to experience gradually ...

  1. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Associated Myelopathy (HAM) Neuromyelitis Optica (NMO) Schilder's Disease Transverse Myelitis d Symptoms & Diagnosis d Diagnosing MS d ... Overview (.pdf) Download Document Pediatric MS Learn More Transverse Myelitis Learn More Neuromyelitis Optica (NMO) Learn More ...

  2. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Directors Senior Leadership Team Founder Sylvia Lawry d Cultural Values d Financials Annual Reports Sources of Support ... MS Connection About the Society Vision Careers Leadership Cultural Values Financials News Press Room MS Prevalence Charitable ...

  3. Characterization of ion processes in a GC/DMS air quality monitor by integration of the instrument to a mass spectrometer.

    Science.gov (United States)

    Limero, T F; Nazarov, E G; Menlyadiev, M; Eiceman, G A

    2015-02-07

    The air quality monitor (AQM), which included a portable gas chromatograph (GC) and a detector was interfaced to a mass spectrometer (MS) by introducing flow from the GC detector to the atmospheric pressure ion source of the MS. This small GC system, with a gas recirculation loop for carrier and detector make-up gases, comprised an inlet to preconcentrate volatile organic compounds (VOCs) in air, a thermal desorber before the GC column, a differential mobility spectrometer (DMS), and another DMS as an atmospheric pressure ionization source for the MS. Return flow to the internally recirculated air system of the AQM's DMS was replenished using purified air. Although ions and unreacted neutral vapors flowed from the detector through Viton® tubing into the source of the MS, ions were not detected in the MS without the auxillary ion source, (63)Ni as in the mobility detector. The GC-DMS-MS instrument provided a 3-D measurement platform (GC, DMS, and MS analysis) to explore the gas composition inside the GC-DMS recirculation loop and provide DMS-MS measurement of the components of a complex VOC mixture with performance significantly enhanced by mass-analysis, either with mass spectral scans or with an extracted ion chromatogram. This combination of a mobility spectrometer and a mass spectrometer was possible as vapors and ions are carried together through the DMS analyzer, thereby preserving the chromatographic separation efficiency. The critical benefit of this instrument concept is that all flows in and through the thoroughly integrated GC-DMS analyzer are kept intact allowing a full measure of the ion and vapor composition in the complete system. Performance has been evaluated using a synthetic air sample and a sample of airborne vapors in a laboratory. Capabilities and performance values are described using results from AQM-MS analysis of purified air, ambient air from a research laboratory in a chemistry building, and a sample of synthetic air of known composition

  4. MASTR-MS: a web-based collaborative laboratory information management system (LIMS) for metabolomics.

    Science.gov (United States)

    Hunter, Adam; Dayalan, Saravanan; De Souza, David; Power, Brad; Lorrimar, Rodney; Szabo, Tamas; Nguyen, Thu; O'Callaghan, Sean; Hack, Jeremy; Pyke, James; Nahid, Amsha; Barrero, Roberto; Roessner, Ute; Likic, Vladimir; Tull, Dedreia; Bacic, Antony; McConville, Malcolm; Bellgard, Matthew

    2017-01-01

    An increasing number of research laboratories and core analytical facilities around the world are developing high throughput metabolomic analytical and data processing pipelines that are capable of handling hundreds to thousands of individual samples per year, often over multiple projects, collaborations and sample types. At present, there are no Laboratory Information Management Systems (LIMS) that are specifically tailored for metabolomics laboratories that are capable of tracking samples and associated metadata from the beginning to the end of an experiment, including data processing and archiving, and which are also suitable for use in large institutional core facilities or multi-laboratory consortia as well as single laboratory environments. Here we present MASTR-MS, a downloadable and installable LIMS solution that can be deployed either within a single laboratory or used to link workflows across a multisite network. It comprises a Node Management System that can be used to link and manage projects across one or multiple collaborating laboratories; a User Management System which defines different user groups and privileges of users; a Quote Management System where client quotes are managed; a Project Management System in which metadata is stored and all aspects of project management, including experimental setup, sample tracking and instrument analysis, are defined, and a Data Management System that allows the automatic capture and storage of raw and processed data from the analytical instruments to the LIMS. MASTR-MS is a comprehensive LIMS solution specifically designed for metabolomics. It captures the entire lifecycle of a sample starting from project and experiment design to sample analysis, data capture and storage. It acts as an electronic notebook, facilitating project management within a single laboratory or a multi-node collaborative environment. This software is being developed in close consultation with members of the metabolomics research

  5. Fine mapping of the genic male-sterile ms 1 gene in Capsicum annuum L.

    Science.gov (United States)

    Jeong, Kyumi; Choi, Doil; Lee, Jundae

    2018-01-01

    The genomic region cosegregating with the genic male-sterile ms 1 gene of Capsicum annuum L. was delimited to a region of 869.9 kb on chromosome 5 through fine mapping analysis. A strong candidate gene, CA05g06780, a homolog of the Arabidopsis MALE STERILITY 1 gene that controls pollen development, was identified in this region. Genic male sterility caused by the ms 1 gene has been used for the economically efficient production of massive hybrid seeds in paprika (Capsicum annuum L.), a colored bell-type sweet pepper. Previously, a CAPS marker, PmsM1-CAPS, located about 2-3 cM from the ms 1 locus, was reported. In this study, we constructed a fine map near the ms 1 locus using high-resolution melting (HRM) markers in an F 2 population consisting of 1118 individual plants, which segregated into 867 male-fertile and 251 male-sterile plants. A total of 12 HRM markers linked to the ms 1 locus were developed from 53 primer sets targeting intraspecific SNPs derived by comparing genome-wide sequences obtained by next-generation resequencing analysis. Using this approach, we narrowed down the region cosegregating with the ms 1 gene to 869.9 kb of sequence. Gene prediction analysis revealed 11 open reading frames in this region. A strong candidate gene, CA05g06780, was identified; this gene is a homolog of the Arabidopsis MALE STERILITY 1 (MS1) gene, which encodes a PHD-type transcription factor that regulates pollen and tapetum development. Sequence comparison analysis suggested that the CA05g06780 gene is the strongest candidate for the ms 1 gene of paprika. To summarize, we developed a cosegregated marker, 32187928-HRM, for marker-assisted selection and identified a strong candidate for the ms 1 gene.

  6. Human herpesviruses and MS

    DEFF Research Database (Denmark)

    Christensen, Tove

    2007-01-01

    and they are capable of reactivation. Epstein Barr virus (EBV), HHV-6A and varicella zoster virus (VZV) are consistently linked with MS, particularly with respect to epidemiology, antibody responses in serum (EBV) and cerebrospinal fluid (EBV and HHV-6A), and with MS exacerbations that are associated with viral...... reactivation (VZV, HHV-6A and EBV). HHV have the potential for a causal role in MS--they may be key players in the disease process--and this role could be mediated through several direct or indirect mechanisms....

  7. Prescription and illicit psychoactive drugs in oral fluid--LC-MS/MS method development and analysis of samples from Brazilian drivers.

    Science.gov (United States)

    Zancanaro, Ivomar; Limberger, Renata Pereira; Bohel, Paula O; dos Santos, Maíra Kerpel; De Boni, Raquel B; Pechansky, Flavio; Caldas, Eloisa Dutra

    2012-11-30

    This study is part of a larger project designed to investigate the prevalence of psychoactive drug (PAD) use among Brazilian drivers. In this paper we describe the development and validation of an analytical method to analyze 32 prescription and illicit PADs (amphetamines, benzodiazepines, cocaine, cannabis, opioids, ketamine and m-CPP) and metabolites in oral fluid samples collected with a Quantisal™ device. Samples were extracted with ethyl acetate:hexane and analyzed by LC-MS/MS. Instrumental LOD ranged from 0.26 to 0.65 ng/mL. Mean procedural recoveries at 1.3 ng/mL (LLOQ) ranged from 50% to 120% for 24 compounds. Recoveries were concentration independent, with the exception of femproporex, heroin and ecgonine methyl-ester (EME) for which the recovery decreased significantly at higher levels (13 and 52 ng/mL). RSD was drugs, cocaine/metabolites were the analytes most detected in the samples (129; 5.8%), followed by amphetamines/metabolite (69; 3.1%), benzodiazepines (28; 1.2%), cannabinoids (23; 1.1%) and opioids (8; 0.4%). Detection of at least two PADs from different classes accounted for 9.3% of the 236 positive samples. Cocaine was found at higher levels in the samples (up to 1165 ng/mL). Preventive measures aimed at reducing the use of PADs by drivers in Brazil will certainly contribute to decrease the country's highway death rates. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  8. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... working effectively. How does RRMS differ from progressive types of MS? While RRMS is defined by attacks of ... forms of MS involve much less of this type of inflammation. People with RRMS tend to have more ...

  9. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... More Schilder's Disease Learn More The National MS Society is Here to Help Need More Information? We ... Twitter LinkedIn YouTube Pinterest MS Connection About the Society Vision Careers Leadership Cultural Values Financials News Press ...

  10. Prediction of esophageal variceal bleeding in B-viral liver cirrhosis using the P2/MS noninvasive index based on complete blood counts.

    Science.gov (United States)

    Kim, Beom Kyung; Ahn, Sang Hoon; Han, Kwang-Hyub; Park, Jun Yong; Han, Min Seok; Jo, Jung Hyun; Kim, Ja Kyung; Lee, Kwan Sik; Chon, Chae Yoon; Kim, Do Young

    2012-01-01

    Periodic endoscopy for esophageal varices (EVs) and prophylactic treatment of high-risk EVs, i.e., medium/large EVs, small EVs with the red-color sign or decompensation, are recommended in cirrhotic patients. We assessed the cumulative risks for future EV bleeding using the following simple P2/MS index: (platelet count)2/[monocyte fraction (%) × segmented neutrophil fraction (%)]. We enrolled 475 consecutive B-viral cirrhosis patients for 4 years, none of whom experienced EV bleeding. All underwent laboratory work-ups, endoscopy and ultrasonography. Those with EV bleeding took a nonselective β-blocker as prophylaxis. The major endpoint was the first occurrence of EV bleeding, analyzed using the Kaplan-Meier and Cox regression methods. Among patients with EV bleeding (n = 131), 25 experienced their first EV bleeding during follow-up. To differentiate the risk for EV bleeding, we divided them into two subgroups according to their P2/MS value (subgroup 1: P2/MS ≥9 and subgroup 2: P2/MS P2/MS (p = 0.040) remained a significant predictor for EV bleeding along with large varix size (p = 0.015), red-color sign (p = 0.041) and Child-Pugh classification B/C (p = 0.001). In subgroup 1, the risk for EV bleeding was similar to that of patients with low-risk EVs (p = 0.164). The P2/MS is a reliable predictor for the risk of EV bleeding among patients with EV bleeding. According to risk stratification, different prophylactic treatments should be considered for the subgroup with a P2/MS <9. Copyright © 2012 S. Karger AG, Basel.

  11. Explosives and chemical warfare agents - detection and analysis with PTR-MS

    Energy Technology Data Exchange (ETDEWEB)

    Sulzer, Philipp; Juerschik, Simone; Jaksch, Stefan; Jordan, Alfons; Hanel, Gernot; Hartungen, Eugen; Seehauser, Hans; Maerk, Lukas; Haidacher, Stefan; Schottkowsky, Ralf [IONICON Analytik GmbH, Innsbruck (Austria); Petersson, Fredrik [Institut fuer Ionenphysik und Angewandte Physik, Leopold-Franzens Universitaet Innsbruck (Austria); Maerk, Tilmann [IONICON Analytik GmbH, Innsbruck (Austria); Institut fuer Ionenphysik und Angewandte Physik, Leopold-Franzens Universitaet Innsbruck (Austria)

    2010-07-01

    We utilized a recently developed high sensitivity PTR-MS instrument equipped with a high resolution time-of-flight mass analyzer for detailed investigations on explosives and chemical warfare agents (CWAs). We show that with this so called PTR-TOF 8000 it is possible to identify solid explosives (RDX, TNT, HMX, PETN and Semtex A) by analyzing the headspace above small quantities of samples at room temperature and from trace quantities not visible to the naked eye placed on surfaces. As the mentioned solid explosives possess very low vapor pressures, the main challenge for detecting them in the gas phase is to provide an instrument with a sufficient sensitivity. CWAs on the other side have very high vapor pressures but are difficult to identify unambiguously as their nominal molecular masses are usually comparably small and therefore hard to distinguish from harmless everyday-compounds (e.g. mustard gas: 159 g/mol). In the present work we demonstrate that we can detect a broad range of dangerous substances, ranging from the CWA mustard gas to the explosive HMX.

  12. The performance and the characterization of laser ablation aerosol particle time-of-flight mass spectrometry (LAAP-ToF-MS)

    Science.gov (United States)

    Gemayel, Rachel; Hellebust, Stig; Temime-Roussel, Brice; Hayeck, Nathalie; Van Elteren, Johannes T.; Wortham, Henri; Gligorovski, Sasho

    2016-05-01

    Hyphenated laser ablation-mass spectrometry instruments have been recognized as useful analytical tools for the detection and chemical characterization of aerosol particles. Here we describe the performances of a laser ablation aerosol particle time-of-flight mass spectrometer (LAAP-ToF-MS) which was designed for aerodynamic particle sizing using two 405 nm scattering lasers and characterization of the chemical composition of single aerosol particle via ablation/ionization by a 193 nm excimer laser and detection in a bipolar time-of-flight mass spectrometer with a mass resolving power of m/Δm > 600.We describe a laboratory based optimization strategy for the development of an analytical methodology for characterization of atmospheric particles using the LAAP-ToF-MS instrument in combination with a particle generator, a differential mobility analyzer and an optical particle counter. We investigated the influence of particle number concentration, particle size and particle composition on the detection efficiency. The detection efficiency is a product of the scattering efficiency of the laser diodes and the ionization efficiency or hit rate of the excimer laser. The scattering efficiency was found to vary between 0.6 and 1.9 % with an average of 1.1 %; the relative standard deviation (RSD) was 17.0 %. The hit rate exhibited good repeatability with an average value of 63 % and an RSD of 18 %. In addition to laboratory tests, the LAAP-ToF-MS was used to sample ambient air during a period of 6 days at the campus of Aix-Marseille University, situated in the city center of Marseille, France. The optimized LAAP-ToF-MS methodology enables high temporal resolution measurements of the chemical composition of ambient particles, provides new insights into environmental science, and a new investigative tool for atmospheric chemistry and physics, aerosol science and health impact studies.

  13. The allosteric switching mechanism in bacteriophage MS2

    Energy Technology Data Exchange (ETDEWEB)

    Perkett, Matthew R.; Mirijanian, Dina T.; Hagan, Michael F., E-mail: hagan@brandeis.edu [Martin Fisher School of Physics, Brandeis University, Waltham, Massachusetts 02474 (United States)

    2016-07-21

    We use all-atom simulations to elucidate the mechanisms underlying conformational switching and allostery within the coat protein of the bacteriophage MS2. Assembly of most icosahedral virus capsids requires that the capsid protein adopts different conformations at precise locations within the capsid. It has been shown that a 19 nucleotide stem loop (TR) from the MS2 genome acts as an allosteric effector, guiding conformational switching of the coat protein during capsid assembly. Since the principal conformational changes occur far from the TR binding site, it is important to understand the molecular mechanism underlying this allosteric communication. To this end, we use all-atom simulations with explicit water combined with a path sampling technique to sample the MS2 coat protein conformational transition, in the presence and absence of TR-binding. The calculations find that TR binding strongly alters the transition free energy profile, leading to a switch in the favored conformation. We discuss changes in molecular interactions responsible for this shift. We then identify networks of amino acids with correlated motions to reveal the mechanism by which effects of TR binding span the protein. We find that TR binding strongly affects residues located at the 5-fold and quasi-sixfold interfaces in the assembled capsid, suggesting a mechanism by which the TR binding could direct formation of the native capsid geometry. The analysis predicts amino acids whose substitution by mutagenesis could alter populations of the conformational substates or their transition rates.

  14. High-speed and supersonic upward plasma drifts: multi-instrumental study

    Science.gov (United States)

    Astafyeva, E.; Zakharenkova, I.; Hairston, M. R.; Huba, J.; Coley, W. R.

    2017-12-01

    Since the pioneering observations by Aggson et al. (1992, JGR, doi: 10.1002/92JA00644), there have been several reports of the occurrence of high-speed (Vz>800 m/s) and supersonic plasma flows in the post-sunset (e.g., Hysell et al., 1994, JGR, doi: 10.1029/94JA00476; Hanson et al., 1997, JGR, doi: 10.1029/96JA03376) and the pre-dawn sector (Astafyeva and Zakharenkova, 2015, GRL, doi:10.1002/2015GL066369). However, despite this observational evidence, these events remain rare and are not well understood. The main issue is to determine the background conditions leading to the occurrence of these high-speed plasma drifts. In this work, we perform a multi-instrumental study of high-speed and supersonic upward plasma drift events/structures. For this purpose, we analyze data from several ground-based and space-borne instruments, including data from the DMSP, Swarm and C/NOFS (IVM instrument) satellites. In addition to the space-borne instruments, we use data from ground-based GPS-receivers and ionosondes to further investigate the background ionosphere conditions, as well as the effects produced by the plasma bubbles and ionospheric irregularities. Besides the observations, we add the SAMI3/ESF modeling results on plasma bubble simulations and high-speed drifts inside plasma bubbles. TIE-GCM runs (from the CCMC, https://ccmc.gsfc.nasa.gov) are used to define the background atmospheric/ionospheric and electrodynamical conditions leading to the occurrence of the high-speed and supersonic plasma drift events. Our search of events with upward plasma drift exceeding 800 m/s in the data of DMSP for the years 2002-2016 shows that such high-speed events are extremely rare. During this period of time, only 6 events were found, two of them occurred during the recovery phase of a geomagnetic storm, while the other four were detected during geomagnetically quiet conditions. Concerning the generation of such events, our preliminary results show that enhanced electric fields are

  15. Quantification of free and total sialic acid excretion by LC-MS/MS

    NARCIS (Netherlands)

    van der Ham, Maria; Prinsen, Berthil H. C. M. T.; Huijmans, Jan G. M.; Abeling, Nicolaas G. G. M.; Dorland, Bert; Berger, Ruud; de Koning, Tom J.; de Sain-van der Velden, Monique G. M.

    2007-01-01

    The main purpose for measuring urinary free sialic acid (FSA) is to diagnose sialic acid (SA) storage diseases. Elevated amounts of conjugated sialic acid (CSA) are observed in several diseases indicating the need to quantify CSA as well. A LC-MS/MS method for quantification of FSA and total sialic

  16. ms_lims, a simple yet powerful open source laboratory information management system for MS-driven proteomics.

    Science.gov (United States)

    Helsens, Kenny; Colaert, Niklaas; Barsnes, Harald; Muth, Thilo; Flikka, Kristian; Staes, An; Timmerman, Evy; Wortelkamp, Steffi; Sickmann, Albert; Vandekerckhove, Joël; Gevaert, Kris; Martens, Lennart

    2010-03-01

    MS-based proteomics produces large amounts of mass spectra that require processing, identification and possibly quantification before interpretation can be undertaken. High-throughput studies require automation of these various steps, and management of the data in association with the results obtained. We here present ms_lims (http://genesis.UGent.be/ms_lims), a freely available, open-source system based on a central database to automate data management and processing in MS-driven proteomics analyses.

  17. QEMSCAN+LA-ICP-MS: a 'big data' generator for sedimentary provenance analysis

    Science.gov (United States)

    Vermeesch, Pieter; Rittner, Martin; Garzanti, Eduardo

    2017-04-01

    Sedimentary provenance may be traced by 'fingerprinting' sediments with chemical, mineralogical or isotopic means. Normally, each of these provenance proxies is characterised on a separate aliquot of the same sample. For example, the chemical composition of the bulk sample may be analysed by X-ray fluorescence (XRF) on one aliquot, framework petrography on another, heavy mineral analysis on a density separate of a third split, and zircon U-Pb dating on a further density separate of the heavy mineral fraction. The labour intensity of this procedure holds back the widespread application of multi-method provenance studies. We here present a new method to solve this problem and avoid mineral separation by coupling a QEMSCAN electron microscope to an LA-ICP-MS instrument and thereby generate all four aforementioned provenance datasets as part of the same workflow. Given a polished hand specimen, a petrographic thin section, or a grain mount, the QEMSCAN+LA-ICP-MS method produces chemical and mineralogical maps from which the X-Y coordinates of the datable mineral are extracted. These coordinates are subsequently passed on to the laser ablation system for isotopic and, hence, geochronological analysis. In the process of finding all the zircons in a sediment grain mount, the QEMSCAN yields the compositional and mineralogical compositions as byproducts. We have applied the new QEMSCAN+LA-ICP-MS instrument suite to over 100 samples from three large sediment routing systems: (1) the Tigris-Euphrates river catchments and Rub' Al Khali desert in Arabia; (2) the Nile catchment in northeast Africa and (3) desert and beach sands between the Orange and Congo rivers in southwest Africa. These studies reveal (1) that Rub' Al Khali sand is predominantly derived from the Arabian Shield and not from Mesopotamia; (2) that the Blue Nile is the principal source of Nile sand; and (3) that Orange River sand is carried northward by longshore drift nearly 1,800km from South Africa to southern

  18. Rapid and simple determination of polyphyllin I, II, VI, and VII in different harvest times of cultivated Paris polyphylla Smith var. yunnanensis (Franch.) Hand.-Mazz by UPLC-MS/MS and FT-IR.

    Science.gov (United States)

    Wu, Zhe; Zhang, Ji; Xu, Furong; Wang, Yuanzhong; Zhang, Jinyu

    2017-01-01

    Paris Polyphylla Smith var. yunnanensis (Franch.) Hand.-Mazz ("Dian Chonglou" in Chinese) is a famous herbal medicine in China, which is usually well known for activities of anti-cancer, hemolysis, and cytotoxicity. In this study, Fourier transform infrared (FT-IR) spectroscopy coupled with principal component analysis (PCA) and partial least-squares regression (PLSR) was applied to discriminate samples of P. polyphylla var. yunnanensis harvested in different years and determine the content of polyphyllin I, II, VI, and VII in P. polyphylla var. yunnanensis. Meanwhile, ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was used to study the dynamic changes of P. polyphylla var. yunnanensis harvested in different years (4, 5, 7, 8, 9, 12, and 13 years old). According to the UPLC-MS/MS result, the optimum harvest time of P. polyphylla var. yunnanensis is 8 years, due to the highest yield of four active components. By the PCA model, P. polyphylla var. yunnanensis could be exactly discriminated, except that two 8-year-old samples were misclassified as 9-year-old samples. For the prediction of polyphyllin I, II, VI, and VII, the quantitative results are satisfactory, with a high value for the determination coefficient (R 2 ) and low values for the root-mean-square error of estimation (RMSEE), root-mean-square error of cross-validation (RMSECV), and root-mean-square error of prediction (RMSEP). In conclusion, FT-IR combined with chemometrics is a promising method to accurately discriminate samples of P. polyphylla var. yunnanensis harvested in different years and determine the content of polyphyllin I, II, VI, and VII in P. polyphylla var. yunnanensis.

  19. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Review of Society's Research Programs d Careers d Leadership Board of Directors Senior Leadership Team Founder Sylvia Lawry d Cultural Values d ... Pinterest MS Connection About the Society Vision Careers Leadership Cultural Values Financials News Press Room MS Prevalence ...

  20. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Another Condition Aging with MS Anesthesia and Surgery Managing Your MS d Emotional Well-Being Mood Changes d Spiritual Well-Being Building Spirituality into Your Life d Cognitive Health d Work, Home & Leisure Employment Insurance & Financial Information Staying Mobile ...

  1. Comprehensive analysis of proteins of pH fractionated samples using monolithic LC/MS/MS, intact MW measurement and MALDI-QIT-TOF MS

    Science.gov (United States)

    Yoo, Chul; Patwa, Tasneem H.; Kreunin, Paweena; Miller, Fred R.; Huber, Christian G.; Nesvizhskii, Alexey I.; Lubman, David M.

    2012-01-01

    A comprehensive platform that integrates information from the protein and peptide levels by combining various MS techniques has been employed for the analysis of proteins in fully malignant human breast cancer cells. The cell lysates were subjected to chromatofocusing fractionation, followed by tryptic digestion of pH fractions for on-line monolithic RP-HPLC interfaced with linear ion trap MS analysis for rapid protein identification. This unique approach of direct analysis of pH fractions resulted in the identification of large numbers of proteins from several selected pH fractions, in which approximately 1.5 μg of each of the pH fraction digests was consumed for an analysis time of ca 50 min. In order to combine valuable information retained at the protein level with the protein identifications obtained from the peptide level information, the same pH fraction was analyzed using nonporous (NPS)-RP-HPLC/ESI-TOF MS to obtain intact protein MW measurements. In order to further validate the protein identification procedures from the fraction digest analysis, NPS-RP-HPLC separation was performed for off-line protein collection to closely examine each protein using MALDI-TOF MS and MALDI-quadrupole ion trap (QIT)-TOF MS, and excellent agreement of protein identifications was consistently observed. It was also observed that the comparison to intact MW and other MS information was particularly useful for analyzing proteins whose identifications were suggested by one sequenced peptide from fraction digest analysis. PMID:17206599

  2. Quantification of acetaminophen (paracetamol) in human plasma and urine by stable isotope-dilution GC-MS and GC-MS/MS as pentafluorobenzyl ether derivative.

    Science.gov (United States)

    Trettin, Arne; Zoerner, Alexander A; Böhmer, Anke; Gutzki, Frank-Mathias; Stichtenoth, Dirk O; Jordan, Jens; Tsikas, Dimitrios

    2011-08-01

    We report on the quantitative determination of acetaminophen (paracetamol; NAPAP-d(0)) in human plasma and urine by GC-MS and GC-MS/MS in the electron-capture negative-ion chemical ionization (ECNICI) mode after derivatization with pentafluorobenzyl (PFB) bromide (PFB-Br). Commercially available tetradeuterated acetaminophen (NAPAP-d(4)) was used as the internal standard. NAPAP-d(0) and NAPAP-d(4) were extracted from 100-μL aliquots of plasma and urine with 300 μL ethyl acetate (EA) by vortexing (60s). After centrifugation the EA phase was collected, the solvent was removed under a stream of nitrogen gas, and the residue was reconstituted in acetonitrile (MeCN, 100 μL). PFB-Br (10 μL, 30 vol% in MeCN) and N,N-diisopropylethylamine (10 μL) were added and the mixture was incubated for 60 min at 30 °C. Then, solvents and reagents were removed under nitrogen and the residue was taken up with 1000 μL of toluene, from which 1-μL aliquots were injected in the splitless mode. GC-MS quantification was performed by selected-ion monitoring ions due to [M-PFB](-) and [M-PFB-H](-), m/z 150 and m/z 149 for NAPAP-d(0) and m/z 154 and m/z 153 for NAPAP-d(4), respectively. GC-MS/MS quantification was performed by selected-reaction monitoring the transition m/z 150 → m/z 107 and m/z 149 → m/z 134 for NAPAP-d(0) and m/z 154 → m/z 111 and m/z 153 → m/z 138 for NAPAP-d(4). The method was validated for human plasma (range, 0-130 μM NAPAP-d(0)) and urine (range, 0-1300 μM NAPAP-d(0)). Accuracy (recovery, %) ranged between 89 and 119%, and imprecision (RSD, %) was below 19% in these matrices and ranges. A close correlation (r>0.999) was found between the concentrations measured by GC-MS and GC-MS/MS. By this method, acetaminophen can be reliably quantified in small plasma and urine sample volumes (e.g., 10 μL). The analytical performance of the method makes it especially useful in pediatrics. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. The M. D. Anderson Symptom Inventory-Head and Neck Module, a Patient-Reported Outcome Instrument, Accurately Predicts the Severity of Radiation-Induced Mucositis

    International Nuclear Information System (INIS)

    Rosenthal, David I.; Mendoza, Tito R.; Chambers, Mark; Burkett, V. Shannon; Garden, Adam S.; Hessell, Amy C.; Lewin, Jan S.; Ang, K. Kian; Kies, Merrill S.; Gning, Ibrahima; Wang, Xin S.; Cleeland, Charles S.

    2008-01-01

    Purpose: To compare the M. D. Anderson Symptom Inventory-Head and Neck (MDASI-HN) module, a symptom burden instrument, with the Functional Assessment of Cancer Therapy-Head and Neck (FACT-HN) module, a quality-of-life instrument, for the assessment of mucositis in patients with head-and-neck cancer treated with radiotherapy and to identify the most distressing symptoms from the patient's perspective. Methods and Materials: Consecutive patients with head-and-neck cancer (n = 134) completed the MDASI-HN and FACT-HN before radiotherapy (time 1) and after 6 weeks of radiotherapy or chemoradiotherapy (time 2). The mean global and subscale scores for each instrument were compared with the objective mucositis scores determined from the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3.0. Results: The global and subscale scores for each instrument showed highly significant changes from time 1 to time 2 and a significant correlation with the objective mucositis scores at time 2. Only the MDASI scores, however, were significant predictors of objective Common Terminology Criteria for Adverse Events mucositis scores on multivariate regression analysis (standardized regression coefficient, 0.355 for the global score and 0.310 for the head-and-neck cancer-specific score). Most of the moderate and severe symptoms associated with mucositis as identified on the MDASI-HN are not present on the FACT-HN. Conclusion: Both the MDASI-HN and FACT-HN modules can predict the mucositis scores. However, the MDASI-HN, a symptom burden instrument, was more closely associated with the severity of radiation-induced mucositis than the FACT-HN on multivariate regression analysis. This greater association was most likely related to the inclusion of a greater number of face-valid mucositis-related items in the MDASI-HN compared with the FACT-HN

  4. Screening for potential child maltreatment in parents of a newborn baby: The predictive validity of an Instrument for early identification of Parents At Risk for child Abuse and Neglect (IPARAN).

    Science.gov (United States)

    van der Put, Claudia E; Bouwmeester-Landweer, Merian B R; Landsmeer-Beker, Eleonore A; Wit, Jan M; Dekker, Friedo W; Kousemaker, N Pieter J; Baartman, Herman E M

    2017-08-01

    For preventive purposes it is important to be able to identify families with a high risk of child maltreatment at an early stage. Therefore we developed an actuarial instrument for screening families with a newborn baby, the Instrument for identification of Parents At Risk for child Abuse and Neglect (IPARAN). The aim of this study was to assess the predictive validity of the IPARAN and to examine whether combining actuarial and clinical methods leads to an improvement of the predictive validity. We examined the predictive validity by calculating several performance indicators (i.e., sensitivity, specificity and the Area Under the receiver operating characteristic Curve [AUC]) in a sample of 4692 Dutch families with newborns. The outcome measure was a report of child maltreatment at Child Protection Services during a follow-up of 3 years. For 17 children (.4%) a report of maltreatment was registered. The predictive validity of the IPARAN was significantly better than chance (AUC=.700, 95% CI [.567-.832]), in contrast to a low value for clinical judgement of nurses of the Youth Health Care Centers (AUC=.591, 95% CI [.422-.759]). The combination of the IPARAN and clinical judgement resulted in the highest predictive validity (AUC=.720, 95% CI [.593-.847]), however, the difference between the methods did not reach statistical significance. The good predictive validity of the IPARAN in combination with clinical judgment of the nurse enables professionals to assess risks at an early stage and to make referrals to early intervention programs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. HPLC-UV, MALDI-TOF-MS and ESI-MS/MS analysis of the mechlorethamine DNA crosslink at a cytosine-cytosine mismatch pair.

    Directory of Open Access Journals (Sweden)

    Pornchai Rojsitthisak

    Full Text Available Mechlorethamine [ClCH(2CH(2N(CH(3CH(2CH(2Cl], a nitrogen mustard alkylating agent, has been proven to form a DNA interstrand crosslink at a cytosine-cytosine (C-C mismatch pair using gel electrophoresis. However, the atomic connectivity of this unusual crosslink is unknown.HPLC-UV, MALDI-TOF-MS, and ESI-MS/MS were used to determine the atomic connectivity of the DNA C-C crosslink formed by mechlorethamine, MALDI-TOF-MS of the HPLC-purified reaction product of mechlorethamine with the DNA duplex d[CTCACACCGTGGTTC]•d[GAACCACCGTGTGAG] (underlined bases are a C-C mismatch pair indicated formation of an interstrand crosslink at m/z 9222.088 [M-2H+Na](+. Following enzymatic digestion of the crosslinked duplex by snake venom phosphodiesterase and calf intestinal phosphatase, ESI-MS/MS indicated the presence of dC-mech-dC [mech = CH(2CH(2N(CH(3CH(2CH(2] at m/z 269.2 [M](2+ (expected m/z 269.6, exact mass 539.27 and its hydrolytic product dC-mech-OH at m/z 329.6 [M](+ (expected m/z 329.2. Fragmentation of dC-mech-dC gave product ions at m/z 294.3 and 236.9 [M](+, which are both due to loss of the 4-amino group of cytosine (as ammonia, in addition to dC and dC+HN(CH(3CH = CH(2, respectively. The presence of m/z 269.2 [M](2+ and loss of ammonia exclude crosslink formation at cytosine N(4 or O(2 and indicate crosslinking through cytosine N(3 with formation of two quaternary ammonium ions.Our results provide an important addition to the literature, as the first example of the use of HPLC and MS for analysis of a DNA adduct at the N(3 position of cytosine.

  6. Online preconcentration ICP-MS analysis of rare earth elements in seawater

    Science.gov (United States)

    Hathorne, Ed C.; Haley, Brian; Stichel, Torben; Grasse, Patricia; Zieringer, Moritz; Frank, Martin

    2012-01-01

    The rare earth elements (REEs) with their systematically varying properties are powerful tracers of continental inputs, particle scavenging intensity and the oxidation state of seawater. However, their generally low (˜pmol/kg) concentrations in seawater and fractionation potential during chemical treatment makes them difficult to measure. Here we report a technique using an automated preconcentration system, which efficiently separates seawater matrix elements and elutes the preconcentrated sample directly into the spray chamber of an ICP-MS instrument. The commercially available "seaFAST" system (Elemental Scientific Inc.) makes use of a resin with ethylenediaminetriacetic acid and iminodiacetic acid functional groups to preconcentrate REEs and other metals while anions and alkali and alkaline earth cations are washed out. Repeated measurements of seawater from 2000 m water depth in the Southern Ocean allows the external precision (2σ) of the technique to be estimated at mine water reference materials diluted with a NaCl matrix with recommended values in the literature. This makes the online preconcentration ICP-MS technique advantageous for the minimal sample preparation required and the relatively small sample volume consumed (7 mL) thus enabling large data sets for the REEs in seawater to be rapidly acquired.

  7. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Text Print Discover More Here are a few related topics that may interest you Living with MS (.pdf) Download Brochure Focus on Employment (.pdf) Download Brochure Working with MS (.pdf) Download Brochure Taming Stress (.pdf) Download Brochure Multiple Sclerosis and Your Emotions (. ...

  8. Comparison of instrumental neutron activation analysis and instrumental charged-particle activation analysis for determining of Zn-68 abundance

    International Nuclear Information System (INIS)

    Rafii, H.; Mirzaei, M.; Aslani, G.R.; Kamali-Dehghan, M.; Rajamand, A-A.; Rahiminejad, A.; Mirzajani, N.; Sardari, D.; Shahabi, I.; Majidi, F.

    2004-01-01

    Gallium-67 has found important applications in nuclear medicine since last decades. The bombardment of enriched zinc-68 by proton beams in cyclotron is the most suitable method for the carrier-free production of this radionuclide. Any traces and isotopic impurities of the target cause serious radiological hazards because of their associated induced radioactivities. Trace analysis and Zn-68 content determination of the target material before any bombardment and chemical separation provide a valuable assessment of desired product. The elemental abundance evaluation of enriched isotopes is generally carried out by inductively coupled plasma-mass spectrometry method, ICP-Ms Instrumental neutron activation analysis and instrumental charged particle activation analysis. International neutron activation analysis and instrumental charged- particle activation analysis, looks be an alternative nuclear method for determining the abundance evaluation of enriched Zn-68 enrichment in two different samples has been studied by mean of international neutron activation analysis and instrumental charged- particle activation analysis . One sample was purchased from a French company, cortecnet, and the other was separated by an electromagnetic system in the Ions source department of our center, NRCAM. The neutron or proton irradiation was took place respectively in miniature neutron source reactor of Esfahan by flux of (1 to 5) 10 11 n/cm 2 .sec for 30 min and in Cyclon30 by 19 MeV proton beams of 100μA current for 12 min. The produced radioactivity was measured by HpGe detector for determination of trace impurities and evaluation of Zn-68 content in the samples. The result shows a good agreement with the reported ones by their producers and their low derivation of about ± indicates that the international neutron activation analysis and instrumental charged- particle activation analysis are relatively precise and rapid and each one can be used as a supplemental method for analyzing

  9. Determination of {sup 241}Pu in nuclear waste slurries: A comparative study using LSC and ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Jaeggi, M., E-mail: maya.jaeggi@psi.ch [Department Logistics for Radiation Safety and Security, Radioanalytics, CH-5232 Villligen PSI (Switzerland); Roellin, S., E-mail: Stefan.Roellin@babs.admin.ch [Federal Office for Civil Protection, SPIEZ Laboratory, CH-3700 Spiez (Switzerland); Corcho Alvarado, J.A., E-mail: Corcho-Alvarado@chuv.ch [Institute of Radiation Physics, University Hospital and University of Lausanne, Rue du Grand-Pre 1, 1007 Lausanne (Switzerland); Eikenberg, J., E-mail: jost.eikenberg@psi.ch [Department Logistics for Radiation Safety and Security, Radioanalytics, CH-5232 Villligen PSI (Switzerland)

    2012-02-15

    {sup 241}Pu was determined in slurry samples from a nuclear reactor decommissioning project at the Paul Scherrer Institute (Switzerland). To validate the results, the {sup 241}Pu activities of five samples were determined by LSC (TriCarb and Quantulus) and ICP-MS, with each instrument at a different laboratory. In lack of certified reference materials for {sup 241}Pu, the methods were further validated using the {sup 241}Pu information values of two reference sediments (IAEA-300 and IAEA-384). Excellent agreement with the results was found between LSC and ICP-MS in the nuclear waste slurries and the reference sediments. - Highlights: Black-Right-Pointing-Pointer Good agreement between the {sup 241}Pu activity of 5 slurry samples, using 3 measurement techniques. Black-Right-Pointing-Pointer {sup 241}Pu information values of two IAEA samples agreed well for the 3 measurement techniques. Black-Right-Pointing-Pointer Low detection limits were achieved; 1.8 Bq/kg (Quantulus), 2 Bq/kg (ICP-MS) and 3.5 Bq/kg (TriCarb).

  10. Determination of 3-MCPD by GC-MS/MS with PTV-LV injector used for a survey of Spanish foodstuffs.

    Science.gov (United States)

    León, Nuria; Yusà, Vicent; Pardo, Olga; Pastor, Agustín

    2008-05-15

    3-Monochloropropane-1,2-diol (3-MCPD) is the most common chemical contaminant of the group of chloropropanols. It can occur in foods and food ingredients at low levels as a result of processing, migration from packaging materials during storage and domestic cooking. A sensitive method for determination of 3-MCPD in foodstuffs using programmable temperature vaporization (PTV) with large-volume injection (LVI) gas chromatography (GC) with tandem mass spectrometry detection (MS/MS) has been developed and optimized. The optimization of the injection and detection parameters was carried out using statistical experimental design. A Plackett-Burman design was used to estimate the influence of resonance excitation voltage (REV), isolation time (IT), excitation time (ET), ion source temperature (IST), and electron energy (EE) on the analytical response in the ion trap mass spectrometer (ITMS). Only REV was found to have a statically significant effect. On the other hand, a central composite design was used to optimize the settings of injection temperature (T(inlet)), vaporization temperature (T(vap)), vaporization time (t(vap)) and flow (Flow). The optimized method has an instrumental limit of detection (signal-to-noise ratio 3:1) of 0.044 ng mL(-1). From Valencian, Spain, supermarkets 94 samples of foods were surveyed for 3-MCPD. Using the optimized method levels higher than the limit established for soy sauce by the European Union were found in some samples. The estimated daily intake of 3-MCPD throughout the investigated foodstuffs for adults and children was found about 0.005 and 0.01%, respectively, of the established provisional tolerable daily intake.

  11. Quantitative analysis of 39 polybrominated diphenyl ethers by isotope dilution GC/low-resolution MS.

    Science.gov (United States)

    Ackerman, Luke K; Wilson, Glenn R; Simonich, Staci L

    2005-04-01

    A GC/low-resolution MS method for the quantitative isotope dilution analysis of 39 mono- to heptabrominated diphenyl ethers was developed. The effects of two different ionization sources, electron impact (EI) and electron capture negative ionization (ECNI), and the effects of their parameters on production of high-mass fragment ions [M - xH - yBr](-) specific to PBDEs were investigated. Electron energy, emission current, source temperature, ECNI system pressure, and choice of ECNI reagent gases were optimized. Previously unidentified enhancement of PBDE high-mass fragment ion [M - xH - yBr](-) abundance was achieved. Electron energy had the largest impact on PBDE high-mass fragment ion abundance for both the ECNI and EI sources. By monitoring high-mass fragment ions of PBDEs under optimized ECNI source conditions, quantitative isotope dilution analysis of 39 PBDEs was conducted using nine (13)C(12) labeled PBDEs on a low-resolution MS with low picogram to femtogram instrument detection limits.

  12. In Silico Prediction Analysis of Idiotope-Driven T–B Cell Collaboration in Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Rune A. Høglund

    2017-10-01

    Full Text Available Memory B cells acting as antigen-presenting cells are believed to be important in multiple sclerosis (MS, but the antigen they present remains unknown. We hypothesized that B cells may activate CD4+ T cells in the central nervous system of MS patients by presenting idiotopes from their own immunoglobulin variable regions on human leukocyte antigen (HLA class II molecules. Here, we use bioinformatics prediction analysis of B cell immunoglobulin variable regions from 11 MS patients and 6 controls with other inflammatory neurological disorders (OINDs, to assess whether the prerequisites for such idiotope-driven T–B cell collaboration are present. Our findings indicate that idiotopes from the complementarity determining region (CDR 3 of MS patients on average have high predicted affinities for disease associated HLA-DRB1*15:01 molecules and are predicted to be endosomally processed by cathepsin S and L in positions that allows such HLA binding to occur. Additionally, complementarity determining region 3 sequences from cerebrospinal fluid (CSF B cells from MS patients contain on average more rare T cell-exposed motifs that could potentially escape tolerance and stimulate CD4+ T cells than CSF B cells from OIND patients. Many of these features were associated with preferential use of the IGHV4 gene family by CSF B cells from MS patients. This is the first study to combine high-throughput sequencing of patient immune repertoires with large-scale prediction analysis and provides key indicators for future in vitro and in vivo analyses.

  13. Telephone-administered psychotherapy for depression in MS patients: moderating role of social support.

    Science.gov (United States)

    Beckner, Victoria; Howard, Isa; Vella, Lea; Mohr, David C

    2010-02-01

    Depression is common in individuals with multiple sclerosis (MS). While psychotherapy is an effective treatment for depression, not all individuals benefit. We examined whether baseline social support might differentially affect treatment outcome in 127 participants with MS and depression randomized to either Telephone-administered Cognitive-Behavioral Therapy (T-CBT) or Telephone-administered Emotion-Focused Therapy (T-EFT). We predicted that those with low social support would improve more in T-EFT, since this approach emphasizes the therapeutic relationship, while participants with strong social networks and presumably more emotional resources might fare better in the more structured and demanding T-CBT. We found that both level of received support and satisfaction with that support at baseline did moderate treatment outcome. Individuals with high social support showed a greater reduction in depressive symptoms in the T-CBT as predicted, but participants with low social support showed a similar reduction in both treatments. This suggests that for participants with high social support, CBT may be a more beneficial treatment for depression compared with EFT.

  14. CARMENES instrument overview

    Science.gov (United States)

    Quirrenbach, A.; Amado, P. J.; Caballero, J. A.; Mundt, R.; Reiners, A.; Ribas, I.; Seifert, W.; Abril, M.; Aceituno, J.; Alonso-Floriano, F. J.; Ammler-von Eiff, M.; Antona Jiménez, R.; Anwand-Heerwart, H.; Azzaro, M.; Bauer, F.; Barrado, D.; Becerril, S.; Béjar, V. J. S.; Benítez, D.; Berdiñas, Z. M.; Cárdenas, M. C.; Casal, E.; Claret, A.; Colomé, J.; Cortés-Contreras, M.; Czesla, S.; Doellinger, M.; Dreizler, S.; Feiz, C.; Fernández, M.; Galadí, D.; Gálvez-Ortiz, M. C.; García-Piquer, A.; García-Vargas, M. L.; Garrido, R.; Gesa, L.; Gómez Galera, V.; González Álvarez, E.; González Hernández, J. I.; Grözinger, U.; Guàrdia, J.; Guenther, E. W.; de Guindos, E.; Gutiérrez-Soto, J.; Hagen, H.-J.; Hatzes, A. P.; Hauschildt, P. H.; Helmling, J.; Henning, T.; Hermann, D.; Hernández Castaño, L.; Herrero, E.; Hidalgo, D.; Holgado, G.; Huber, A.; Huber, K. F.; Jeffers, S.; Joergens, V.; de Juan, E.; Kehr, M.; Klein, R.; Kürster, M.; Lamert, A.; Lalitha, S.; Laun, W.; Lemke, U.; Lenzen, R.; López del Fresno, Mauro; López Martí, B.; López-Santiago, J.; Mall, U.; Mandel, H.; Martín, E. L.; Martín-Ruiz, S.; Martínez-Rodríguez, H.; Marvin, C. J.; Mathar, R. J.; Mirabet, E.; Montes, D.; Morales Muñoz, R.; Moya, A.; Naranjo, V.; Ofir, A.; Oreiro, R.; Pallé, E.; Panduro, J.; Passegger, V.-M.; Pérez-Calpena, A.; Pérez Medialdea, D.; Perger, M.; Pluto, M.; Ramón, A.; Rebolo, R.; Redondo, P.; Reffert, S.; Reinhardt, S.; Rhode, P.; Rix, H.-W.; Rodler, F.; Rodríguez, E.; Rodríguez-López, C.; Rodríguez-Pérez, E.; Rohloff, R.-R.; Rosich, A.; Sánchez-Blanco, E.; Sánchez Carrasco, M. A.; Sanz-Forcada, J.; Sarmiento, L. F.; Schäfer, S.; Schiller, J.; Schmidt, C.; Schmitt, J. H. M. M.; Solano, E.; Stahl, O.; Storz, C.; Stürmer, J.; Suárez, J. C.; Ulbrich, R. G.; Veredas, G.; Wagner, K.; Winkler, J.; Zapatero Osorio, M. R.; Zechmeister, M.; Abellán de Paco, F. J.; Anglada-Escudé, G.; del Burgo, C.; Klutsch, A.; Lizon, J. L.; López-Morales, M.; Morales, J. C.; Perryman, M. A. C.; Tulloch, S. M.; Xu, W.

    2014-07-01

    This paper gives an overview of the CARMENES instrument and of the survey that will be carried out with it during the first years of operation. CARMENES (Calar Alto high-Resolution search for M dwarfs with Exoearths with Near-infrared and optical Echelle Spectrographs) is a next-generation radial-velocity instrument under construction for the 3.5m telescope at the Calar Alto Observatory by a consortium of eleven Spanish and German institutions. The scientific goal of the project is conducting a 600-night exoplanet survey targeting ~ 300 M dwarfs with the completed instrument. The CARMENES instrument consists of two separate echelle spectrographs covering the wavelength range from 0.55 to 1.7 μm at a spectral resolution of R = 82,000, fed by fibers from the Cassegrain focus of the telescope. The spectrographs are housed in vacuum tanks providing the temperature-stabilized environments necessary to enable a 1 m/s radial velocity precision employing a simultaneous calibration with an emission-line lamp or with a Fabry-Perot etalon. For mid-M to late-M spectral types, the wavelength range around 1.0 μm (Y band) is the most important wavelength region for radial velocity work. Therefore, the efficiency of CARMENES has been optimized in this range. The CARMENES instrument consists of two spectrographs, one equipped with a 4k x 4k pixel CCD for the range 0.55 - 1.05 μm, and one with two 2k x 2k pixel HgCdTe detectors for the range from 0.95 - 1.7μm. Each spectrograph will be coupled to the 3.5m telescope with two optical fibers, one for the target, and one for calibration light. The front end contains a dichroic beam splitter and an atmospheric dispersion corrector, to feed the light into the fibers leading to the spectrographs. Guiding is performed with a separate camera; on-axis as well as off-axis guiding modes are implemented. Fibers with octagonal cross-section are employed to ensure good stability of the output in the presence of residual guiding errors. The

  15. Spatial Topography of Individual-Specific Cortical Networks Predicts Human Cognition, Personality, and Emotion.

    Science.gov (United States)

    Kong, Ru; Li, Jingwei; Orban, Csaba; Sabuncu, Mert R; Liu, Hesheng; Schaefer, Alexander; Sun, Nanbo; Zuo, Xi-Nian; Holmes, Avram J; Eickhoff, Simon B; Yeo, B T Thomas

    2018-06-06

    Resting-state functional magnetic resonance imaging (rs-fMRI) offers the opportunity to delineate individual-specific brain networks. A major question is whether individual-specific network topography (i.e., location and spatial arrangement) is behaviorally relevant. Here, we propose a multi-session hierarchical Bayesian model (MS-HBM) for estimating individual-specific cortical networks and investigate whether individual-specific network topography can predict human behavior. The multiple layers of the MS-HBM explicitly differentiate intra-subject (within-subject) from inter-subject (between-subject) network variability. By ignoring intra-subject variability, previous network mappings might confuse intra-subject variability for inter-subject differences. Compared with other approaches, MS-HBM parcellations generalized better to new rs-fMRI and task-fMRI data from the same subjects. More specifically, MS-HBM parcellations estimated from a single rs-fMRI session (10 min) showed comparable generalizability as parcellations estimated by 2 state-of-the-art methods using 5 sessions (50 min). We also showed that behavioral phenotypes across cognition, personality, and emotion could be predicted by individual-specific network topography with modest accuracy, comparable to previous reports predicting phenotypes based on connectivity strength. Network topography estimated by MS-HBM was more effective for behavioral prediction than network size, as well as network topography estimated by other parcellation approaches. Thus, similar to connectivity strength, individual-specific network topography might also serve as a fingerprint of human behavior.

  16. How much separation for LC-MS/MS quantitative bioanalysis of drugs and metabolites?

    Science.gov (United States)

    Tan, Aimin; Fanaras, John C

    2018-05-01

    LC-MS/MS has been the dominant analytical technology for quantitative bioanalysis of drugs and metabolites for more than two decades. Despite this, a very fundamental question like how much separation is required for LC-MS/MS quantitative bioanalysis of drugs and metabolites has not been adequately addressed. Some think that no or only very limited separation is necessary thanks to the unparalleled selectivity offered by tandem mass spectrometry. Others think that the more separation, the better, because of the potential detrimental impact of matrix effect (ion suppression or enhancement). Still others just use a rule-of-thumb approach by keeping the adjusted retention/capacity factor always between 2 and 5. The purpose of this article is to address this fundamental question through rational thinking together with various real case examples drawn from regulated bioanalytical laboratories. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Reference Proteome Extracts for Mass Spec Instrument Performance Validation and Method Development

    Science.gov (United States)

    Rosenblatt, Mike; Urh, Marjeta; Saveliev, Sergei

    2014-01-01

    Biological samples of high complexity are required to test protein mass spec sample preparation procedures and validate mass spec instrument performance. Total cell protein extracts provide the needed sample complexity. However, to be compatible with mass spec applications, such extracts should meet a number of design requirements: compatibility with LC/MS (free of detergents, etc.)high protein integrity (minimal level of protein degradation and non-biological PTMs)compatibility with common sample preparation methods such as proteolysis, PTM enrichment and mass-tag labelingLot-to-lot reproducibility Here we describe total protein extracts from yeast and human cells that meet the above criteria. Two extract formats have been developed: Intact protein extracts with primary use for sample preparation method development and optimizationPre-digested extracts (peptides) with primary use for instrument validation and performance monitoring

  18. Aquarius: The Instrument and Initial Results

    Science.gov (United States)

    Vine, David M Le; Lagerloef, G.S.E.; Ruf, C.; Wentz, F.; Yueh, S.; Piepmeier, J.; Lindstrom, E.; Dinnat, E.

    2012-01-01

    Aquarius was launched on June 10, 2011 aboard the Aquarius/SAC-D observatory and the instrument has been operating continuously since the initial turned-on was completed on August 25. The initial observed antenna temperatures were close to predicted and the first salinity map was released in September. In order to map the ocean salinity field, Aquarius includes several special features such as the inclusion of a scatterometer to provide a roughness correction, measurement of the third Stokes parameter to correct for Faraday rotation, and fast sampling to mitigate the effects of RFI. This paper provides an overview of the instrument and an example of initial results. Details are covered in subsequent papers in the session on Aquarius

  19. A uHPLC-MS mathematical modeling approach to dry powder inhaler single agglomerate analysis.

    Science.gov (United States)

    Pennington, Justin; Lena, John; Medendorp, Joseph; Ewing, Gary

    2011-10-01

    Demonstration of content uniformity (CU) is critical toward the successful development of dry powder inhalers (DPIs). Methods for unit dose CU determination for DPI products are well-established within the field of respiratory science. Recent advances in the area include a uHPLC-MS method for high-throughput uniformity analysis, which allows for a greater understanding of blending operations as the industry transitions to a quality-by-design approach to development. Further enhancements to this uHPLC-MS method now enable it to determine CU and sample weight at the single agglomerate level, which is roughly 50× smaller than a unit dose. When coupled with optical microscopy-based agglomerate sizing, the enhanced uHPLC-MS method can also predict the density and porosity of individual agglomerates. Expanding analytical capabilities to the single agglomerate level provides greater insights and confidence in the DPI manufacturing process.

  20. COMPARISON OF COMMERCIAL LC MS/MS COMPATIBLE DETERGENTS WITH SODIUM DEOXYCHOLATE FOR SHOTGUN PROTEOMICS

    Directory of Open Access Journals (Sweden)

    Caleb J. Porter

    2014-12-01

    Full Text Available In this study, we compared the performance of sodium deoxycholate (SDC with several commercially available LC MS/MS compatible detergents for digestion of complex proteomic mixtures. First, the parameters affecting in-solution digestion using SDC were investigated with a full factorial experimental design. Metrics explored were trypsin ratio, digestion time, and concentration of SDC. These parameters were not found to be statistically associated with total peptide identifications in the experimental space investigated. However, in terms of digestion efficiency, digestion time was highly significant (p = 0.0095 as determined by the percent of peptides identified with missed cleavages. The optimized protocol for peptide identification and throughput was used to compare the performance of SDC with various commercially available LC MS/MS compatible surfactants namely Invitrosol, RapiGest, and PPS Silent Surfactant. The detergents were found to be similar through comparisons of the total identified peptides and the hydrophobicity of recovered peptides. We found suitable recovery across a large range of SDC concentrations determined from a bicinchoninic acid (BCA assay. In a spike down experiment, no distinct differences in total number of peptide identifications were discovered when comparing PPS (Silent Surfactant and SDC for preparation of peptide samples derived from low protein amounts (< 20 µg. Combined, these results indicate that SDC is a cost effective alternative to other commonly used LC MS/MS compatible surfactants

  1. pyOpenMS: a Python-based interface to the OpenMS mass-spectrometry algorithm library.

    Science.gov (United States)

    Röst, Hannes L; Schmitt, Uwe; Aebersold, Ruedi; Malmström, Lars

    2014-01-01

    pyOpenMS is an open-source, Python-based interface to the C++ OpenMS library, providing facile access to a feature-rich, open-source algorithm library for MS-based proteomics analysis. It contains Python bindings that allow raw access to the data structures and algorithms implemented in OpenMS, specifically those for file access (mzXML, mzML, TraML, mzIdentML among others), basic signal processing (smoothing, filtering, de-isotoping, and peak-picking) and complex data analysis (including label-free, SILAC, iTRAQ, and SWATH analysis tools). pyOpenMS thus allows fast prototyping and efficient workflow development in a fully interactive manner (using the interactive Python interpreter) and is also ideally suited for researchers not proficient in C++. In addition, our code to wrap a complex C++ library is completely open-source, allowing other projects to create similar bindings with ease. The pyOpenMS framework is freely available at https://pypi.python.org/pypi/pyopenms while the autowrap tool to create Cython code automatically is available at https://pypi.python.org/pypi/autowrap (both released under the 3-clause BSD licence). © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Do Instrumental Activities of Daily Living Predict Dementia at 1- and 2-Year Follow-Up? Findings from the Development of Screening Guidelines and Diagnostic Criteria for Predementia Alzheimer's Disease Study

    NARCIS (Netherlands)

    Sikkes, S.A.M.; Visser, P.J.; Knol, D.L.; de Klerk, E.S.M.; Tsolaki, M.; Frisoni, G. B.; Nobili, F.; Spiru, L.; Rigaud, A.S.; Froelich, L.; Rikkert, M.O.; Soininen, H.; Touchon, J.; Wilcock, G.; Boada, M.; Hampel, H.; Bullock, R.; Vellas, B.; Pijnenburg, Y.A.L.; Scheltens, P.; Verhey, F.R.J.; Uitdehaag, B.M.J.

    2011-01-01

    Objectives To investigate whether problems in instrumental activities of daily living (IADL) can add to conventionally used clinical measurements in helping to predict a diagnosis of dementia at 1- and 2-year follow-up. Design Multicenter prospective cohort study. Setting Memory clinics in Europe.

  3. Metabolic investigation of host/pathogen interaction using MS2-infected Escherichia coli

    Directory of Open Access Journals (Sweden)

    Jain Rishi

    2009-12-01

    Full Text Available Abstract Background RNA viruses are responsible for a variety of illnesses among people, including but not limited to the common cold, the flu, HIV, and ebola. Developing new drugs and new strategies for treating diseases caused by these viruses can be an expensive and time-consuming process. Mathematical modeling may be used to elucidate host-pathogen interactions and highlight potential targets for drug development, as well providing the basis for optimizing patient treatment strategies. The purpose of this work was to determine whether a genome-scale modeling approach could be used to understand how metabolism is impacted by the host-pathogen interaction during a viral infection. Escherichia coli/MS2 was used as the host-pathogen model system as MS2 is easy to work with, harmless to humans, but shares many features with eukaryotic viruses. In addition, the genome-scale metabolic model of E. coli is the most comprehensive model at this time. Results Employing a metabolic modeling strategy known as "flux balance analysis" coupled with experimental studies, we were able to predict how viral infection would alter bacterial metabolism. Based on our simulations, we predicted that cell growth and biosynthesis of the cell wall would be halted. Furthermore, we predicted a substantial increase in metabolic activity of the pentose phosphate pathway as a means to enhance viral biosynthesis, while a break down in the citric acid cycle was predicted. Also, no changes were predicted in the glycolytic pathway. Conclusions Through our approach, we have developed a technique of modeling virus-infected host metabolism and have investigated the metabolic effects of viral infection. These studies may provide insight into how to design better drugs. They also illustrate the potential of extending such metabolic analysis to higher order organisms, including humans.

  4. The neurophysiologist perspective into MS plasticity

    Directory of Open Access Journals (Sweden)

    Elise eHoudayer

    2015-09-01

    Full Text Available Multiple sclerosis (MS is a frequent, highly debilitating inflammatory demyelinating disease, starting to manifest in early adulthood and presenting a wide variety of symptoms which are often resistant to pharmacological treatments. Cortical dysfunctions have been demonstrated to be key components of MS condition, and plasticity of the corticospinal motor system is highly involved in major MS symptoms, such as fatigue, spasticity or pain. Cortical dysfunction in MS can be studied with neurophysiological tools such as electroencephalography (EEG and related techniques (evoked potentials – EPs or transcranial magnetic stimulation (TMS. These techniques are now widely used to provide essential elements of MS diagnosis and can also be used to modulate plasticity. Indeed the recent development of non-invasive brain stimulation (NIBS techniques able to induce cortical plasticity, such as repetitive TMS or transcranial direct current stimulation (tDCS, has brought promising results as add-on treatments.In this review we will focus on the use of these tools (EEG, TMS to study plasticity in MS and on the major techniques used to modulate plasticity in MS.

  5. The Neurophysiologist Perspective into MS Plasticity.

    Science.gov (United States)

    Houdayer, Elise; Comi, Giancarlo; Leocani, Letizia

    2015-01-01

    Multiple sclerosis (MS) is a frequent, highly debilitating inflammatory demyelinating disease, starting to manifest in early adulthood and presenting a wide variety of symptoms, which are often resistant to pharmacological treatments. Cortical dysfunctions have been demonstrated to be key components of MS condition, and plasticity of the corticospinal motor system is highly involved in major MS symptoms, such as fatigue, spasticity, or pain. Cortical dysfunction in MS can be studied with neurophysiological tools, such as electroencephalography (EEG) and related techniques (evoked potentials) or transcranial magnetic stimulation (TMS). These techniques are now widely used to provide essential elements of MS diagnosis and can also be used to modulate plasticity. Indeed, the recent development of non-invasive brain stimulation techniques able to induce cortical plasticity, such as repetitive TMS or transcranial direct current stimulation, has brought promising results as add-on treatments. In this review, we will focus on the use of these tools (EEG and TMS) to study plasticity in MS and on the major techniques used to modulate plasticity in MS.

  6. Development of quality control and instrumentation performance metrics for diffuse optical spectroscopic imaging instruments in the multi-center clinical environment

    Science.gov (United States)

    Keene, Samuel T.; Cerussi, Albert E.; Warren, Robert V.; Hill, Brian; Roblyer, Darren; Leproux, AnaÑ--s.; Durkin, Amanda F.; O'Sullivan, Thomas D.; Haghany, Hosain; Mantulin, William W.; Tromberg, Bruce J.

    2013-03-01

    Instrument equivalence and quality control are critical elements of multi-center clinical trials. We currently have five identical Diffuse Optical Spectroscopic Imaging (DOSI) instruments enrolled in the American College of Radiology Imaging Network (ACRIN, #6691) trial located at five academic clinical research sites in the US. The goal of the study is to predict the response of breast tumors to neoadjuvant chemotherapy in 60 patients. In order to reliably compare DOSI measurements across different instruments, operators and sites, we must be confident that the data quality is comparable. We require objective and reliable methods for identifying, correcting, and rejecting low quality data. To achieve this goal, we developed and tested an automated quality control algorithm that rejects data points below the instrument noise floor, improves tissue optical property recovery, and outputs a detailed data quality report. Using a new protocol for obtaining dark-noise data, we applied the algorithm to ACRIN patient data and successfully improved the quality of recovered physiological data in some cases.

  7. Maternal overprotection score of the Parental Bonding Instrument predicts the outcome of cognitive behavior therapy by trainees for depression.

    Science.gov (United States)

    Asano, Motoshi; Esaki, Kosei; Wakamatsu, Aya; Kitajima, Tomoko; Narita, Tomohiro; Naitoh, Hiroshi; Ozaki, Norio; Iwata, Nakao

    2013-07-01

    The purpose of this study was to predict the outcome of cognitive behavior therapy (CBT) by trainees for major depressive disorder (MDD) based on the Parental Bonding Instrument (PBI). The hypothesis was that the higher level of care and/or lower level of overprotection score would predict a favorable outcome of CBT by trainees. The subjects were all outpatients with MDD treated with CBT as a training case. All the subjects were asked to fill out the Japanese version of the PBI before commencing the course of psychotherapy. The difference between the first and the last Beck Depression Inventory (BDI) score was used to represent the improvement of the intensity of depression by CBT. In order to predict improvement (the difference of the BDI scores) as the objective variable, multiple regression analysis was performed using maternal overprotection score and baseline BDI score as the explanatory variables. The multiple regression model was significant (P = 0.0026) and partial regression coefficient for the maternal overprotection score and the baseline BDI was -0.73 (P = 0.0046) and 0.88 (P = 0.0092), respectively. Therefore, when a patient's maternal overprotection score of the PBI was lower, a better outcome of CBT was expected. The hypothesis was partially supported. This result would be useful in determining indications for CBT by trainees for patients with MDD. © 2013 The Authors. Psychiatry and Clinical Neurosciences © 2013 Japanese Society of Psychiatry and Neurology.

  8. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Min, E-mail: limin22000@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jiang, Xiang-sen, E-mail: jiangxiangsen123@126.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Li, E-mail: leely1976@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Peng, Zhao-hui, E-mail: zhaohuipeng_R@163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Mu, Nan-nan, E-mail: munannan22000@sohu.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China)

    2012-09-15

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality.

  9. A Mass Spectrometry-Based Predictive Strategy Reveals ADAP1 is Phosphorylated at Tyrosine 364

    Energy Technology Data Exchange (ETDEWEB)

    Littrell, BobbiJo R [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-04-16

    The goal of this work was to identify phosphorylation sites within the amino acid sequence of human ADAP1. Using traditional mass spectrometry-based techniques we were unable to produce interpretable spectra demonstrating modification by phosphorylation. This prompted us to employ a strategy in which phosphorylated peptides were first predicted using peptide mapping followed by targeted MS/MS acquisition. ADAP1 was immunoprecipitated from extracts of HEK293 cells stably-transfected with ADAP1 cDNA. Immunoprecipitated ADAP1 was digested with proteolytic enzymes and analyzed by LC-MS in MS1 mode by high-resolution quadrupole time-of-flight mass spectrometry (QTOF-MS). Peptide molecular features were extracted using an untargeted data mining algorithm. Extracted peptide neutral masses were matched against the ADAP1 amino acid sequence with phosphorylation included as a predicted modification. Peptides with predicted phosphorylation sites were analyzed by targeted LC-MS2. Acquired MS2 spectra were then analyzed using database search engines to confirm phosphorylation. Spectra of phosphorylated peptides were validated by manual interpretation. Further confirmation was performed by manipulating phospho-peptide abundance using calf intestinal phosphatase (CIP) and the phorbol ester, phorbol 12-myristate 13-acetate (PMA). Of five predicted phosphopeptides, one, comprised of the sequence AVDRPMLPQEYAVEAHFK, was confirmed to be phosphorylated on a Tyrosine at position 364. Pre-treatment of cells with PMA prior to immunoprecipitation increased the ratio of phosphorylated to unphosphorylated peptide as determined by area counts of extracted ion chromatograms (EIC). Addition of CIP to immunoprecipitation reactions eliminated the phosphorylated form. A novel phosphorylation site was identified at Tyrosine 364. Phosphorylation at this site is increased by treatment with PMA. PMA promotes membrane translocation and activation of protein kinase C (PKC), indicating that Tyrosine 364

  10. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    International Nuclear Information System (INIS)

    Sun, Gang; Li, Min; Jiang, Xiang-sen; Li, Li; Peng, Zhao-hui; Mu, Nan-nan

    2012-01-01

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality

  11. Applications of a glove-box ICP-MS for the analysis of nuclear materials

    International Nuclear Information System (INIS)

    Garcia Alonso, J.I.; Babelot, J.F.; Glatz, J.P.; Cromboom, O.; Koch, L.

    1993-01-01

    The relatively new analytical technique, Inductively Coupled Plasma Mass Spectrometry (ICP-MS), has been used for the analysis of nuclear materials stemming from different parts of the nuclear fuel cycle. The original instrument has been modified in order to work with radioactive materials in a glove box. The plasma torch and vacuum interface are situated inside the glove box while the mass spectrometer and associated electronics are outside. Samples analysed include fresh nuclear fuels (natural impurities), spent fuels (fission products and actinides), reprocessing solutions (minor actinides) and leachates of spent fuel and high level waste glasses (natural elements, fission products and actinides). (orig.)

  12. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors

  13. Achieving a predictable 24-hour return to normal activities after breast augmentation: part II. Patient preparation, refined surgical techniques, and instrumentation.

    Science.gov (United States)

    Tebbetts, John B

    2006-12-01

    The goal of this study was to develop practices that would allow patients undergoing subpectoral augmentation to predictably return to full normal activities within 24 hours after the operation, free of postoperative adjuncts. Part I of this study used motion and time study principles to reduce operative times, medication dosages, perioperative morbidity, and recovery times in augmentation mammaplasty. Part II of the study focuses on details of patient education, preoperative planning, instrumentation, and surgical technique modifications that were identified, modified, and implemented to achieve the results reported in part I. Two groups of 16 patients each (groups 1 and 2) were studied retrospectively for comparison to a third group of 627 patients (group 3) studied prospectively. Patients in group 1 had axillary partial retropectoral breast augmentations in 1982-1983, using dissociative anesthesia, blunt instrument implant pocket dissection, and Dow Corning, double-lumen implants containing 20 mg of methylprednisolone and 20 cc of saline in the outer lumen of the implants. Patients in group 2 (1990) had inframammary, retromammary augmentations by using a combination of blunt and electrocautery dissection, Surgitek Replicon polyurethane-covered, silicone gel-filled implants, and general endotracheal anesthesia. Patients in group 3 (1998 to 2001, n = 627) had inframammary partial retropectoral, inframammary retromammary, and axillary partial retropectoral augmentations under general endotracheal anesthesia. Refined practices and surgical techniques from studies of groups 1 and 2 were applied in group 3. Videotapes from operative procedures of groups 1 and 2 were analyzed with macromotion and micromotion study principles, and tables of events were formulated for each move during the operation for all personnel in the operating room. Extensive details of surgical technique were examined and reexamined in 13 different stages by using principles of motion and time

  14. Chemical characterization of Azadirachta indica grafted on Melia azedarach and analyses of azadirachtin by HPLC-MS-MS (SRM) and meliatoxins by MALDI-MS.

    Science.gov (United States)

    Forim, Moacir Rossi; Cornélio, Vivian Estevam; da Silva, M Fátima das G F; Rodrigues-Filho, Edson; Fernandes, João B; Vieira, Paulo C; Matinez, Sueli Souza; Napolitano, Michael P; Yost, Richard A

    2010-01-01

    Melia azedarach adapted to cool climates was selected as rootstocks for vegetative propagation of Azadirachta indica. Cleft grafting of A. indica on M. azedarach rootstock showed excellent survival. Little is known about the chemistry of grafting. The roots, stems, leaves and seeds of this graft were examined in order to verify if grafted A. indica would produce limonoids different from those found in non-grafted plants. Intact matured fruits were also studied to verify if they were free of meliatoxins. After successive chromatographic separations the extracts afforded several limonoids. HPLC-MS/MS and MALDI-MS were used to develop sensitive methods for detecting azadirachtin on all aerial parts of this graft and meliatoxins in fruits, respectively. The stem afforded the limonoid salannin, which was previously found in the oil seeds of A. indica. Salannin is also found in the root bark of M. azedarach. Thus, the finding of salannin in this study suggests that it could have been translocated from the M. azedarach rootstock to the A. indica graft. HPLC-MS/MS analyses showed that azadirachtin was present in all parts of the fruits, stem, flowers and root, but absent in the leaves. The results of MALDI-MS analyses confirmed the absence of meliatoxins in graft fruits. This study showed that A. indica grafted onto M. azedarach rootstock produces azadirachtin, and also that its fruits are free of meliatoxins from rootstocks, confirming that this graft forms an excellent basis for breeding vigorous Neem trees in cooler regions.

  15. The utility of ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) for clinically relevant steroid analysis.

    Science.gov (United States)

    Storbeck, Karl-Heinz; Gilligan, Lorna; Jenkinson, Carl; Baranowski, Elizabeth S; Quanson, Jonathan L; Arlt, Wiebke; Taylor, Angela E

    2018-05-15

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) assays are considered the reference standard for serum steroid hormone analyses, while full urinary steroid profiles are only achievable by gas chromatography (GC-MS). Both LC-MS/MS and GC-MS have well documented strengths and limitations. Recently, commercial ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) systems have been developed. These systems combine the resolution of GC with the high-throughput capabilities of UHPLC. Uptake of this new technology into research and clinical labs has been slow, possibly due to the perceived increase in complexity. Here we therefore present fundamental principles of UHPSFC-MS/MS and the likely applications for this technology in the clinical research setting, while commenting on potential hurdles based on our experience to date. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Simultaneous Determination of Cyclosporine A, Tacrolimus, Sirolimus, and Everolimus in Whole-Blood Samples by LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Mustafa Karapirli

    2012-01-01

    Full Text Available Objectives. Cyclosporine A (CyA, tacrolimus (TRL, sirolimus (SIR, and everolimus (RAD are immunosuppressive drugs frequently used in organ transplantation. Our aim was to confirm a robust sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS method for determination of CyA, TRL, SIR, and RAD in whole-blood samples. Materials and Methods. We used an integrated online solid-phase extraction-LC-MS/MS system and atmospheric pressure ionization tandem mass spectrometry (API-MS/MS in the multiple reaction monitoring (MRM detection mode. CyA, TRL, SIR, and RAD were simultaneously analyzed in whole blood treated with precipitation reagent taken from transplant patients. Results. System performance parameters were suitable for using this method as a high-throughput technique in clinical practice. The high concentration of one analyte in the sample did not affect the concentration of other analytes. Total analytical time was 2.5 min, and retention times of all analytes were shorter than 2 minutes. Conclusion. This LC-MS/MS method can be preferable for therapeutic drug monitoring of these immunosuppressive drugs (CyA, TRL, SRL, and RAD in whole blood. Sample preparation was too short and simple in this method, and it permits robust, rapid, sensitive, selective, and simultaneous determination of these drugs.

  17. An instrument based on protection motivation theory to predict Chinese adolescents' intention to engage in protective behaviors against schistosomiasis.

    Science.gov (United States)

    Xiao, Han; Peng, Minjin; Yan, Hong; Gao, Mengting; Li, Jingjing; Yu, Bin; Wu, Hanbo; Li, Shiyue

    2016-01-01

    Further advancement in schistosomiasis prevention requires new tools to assess protective motivation, and promote innovative intervention program. This study aimed to develop and evaluate an instrument developed based on the Protection Motivation Theory (PMT) to predict protective behavior intention against schistosomiasis among adolescents in China. We developed the Schistosomiasis PMT Scale based on two appraisal pathways of protective motivation- threat appraisal pathway and coping appraisal pathway. Data from a large sample of middle school students ( n  = 2238, 51 % male, mean age 13.13 ± 1.10) recruited in Hubei, China was used to evaluated the validity and reliability of the scale. The final scale contains 18 items with seven sub-constructs. Cronbach's Alpha coefficients for the entire instrument was 0.76, and for the seven sub-constructs of severity, vulnerability, intrinsic reward, extrinsic reward, response efficacy, self-efficacy and response cost was 0.56, 0.82, 0.75, 0.80, 0.90, 0.72 and 0.70, respectively. The construct validity analysis revealed that the one level 7 sub-constructs model fitted data well (GFI = 0.98, CFI = 0.98, RMSEA = 0.03, Chi-sq/df = 3.90, p  motivation in schistosomiasis prevention control. Further studies are needed to develop more effective intervention programs for schistosomiasis prevention.

  18. A UPLC-MS/MS method for analysis of vancomycin in human cerebrospinal fluid and comparison with the chemiluminescence immunoassay.

    Science.gov (United States)

    Mei, Shenghui; Wang, Jiaqing; Zhu, Leting; Chen, Ruiling; Li, Xingang; Chen, Kai; Chen, Guangqiang; Zhou, Jianxin; Wang, Qiang; Zhao, Zhigang

    2017-08-01

    Vancomycin (VCM) is clinically used in treating patients with postoperative intracranial infections. The cerebrospinal fluid (CSF) concentration of VCM varies greatly among patients. To guide the dosage regimens, monitoring of VCM in CSF is needed. However a method for analysis of VCM in human CSF is lacking. An ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for analysis of VCM in human CSF, and the agreement of UPLC-MS/MS and chemiluminescence immunoassay (CLIA) in the analysis of CSF VCM was evaluated. The ion transitions were m/z 725.5 > 144.1 for VCM and m/z 455.2 > 308.2 for methotrexate (internal standard). The agreement between UPLC-MS/MS and CLIA was evaluated by Bland-Altman plot in 179 samples. The calibration range of the UPLC-MS/MS method was 1-400 mg/L. The inaccuracy and imprecision were -0.69-10.80% and  0.98). The 95% limit of agreement of the ratio of CLIA to UPLC-MS/MS was 61.66-107.40%. Further studies are warranted to confirm the results. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Development and validation of analytical method for Naftopidil in human plasma by LC–MS/MS

    Directory of Open Access Journals (Sweden)

    Pritam S. Jain

    2015-09-01

    Full Text Available A highly sensitive and simple high-performance liquid chromatographic–tandem mass spectrometric (LC–MS-MS assay is developed and validated for the quantification of Naftopidil in human plasma. Naftopidil is extracted from human plasma by methyl tertiary butyl ether and analyzed using a reversed-phase gradient elution on a discovery C 18 5 μ (50 × 4.6 column. A methanol: 2 mM ammonium formate (90:10 as mobile phase, is used and detection was performed by MS using electrospray ionization in positive mode. Propranolol is used as the internal standard. The lower limits of quantification are 0.495 ng/mL. The calibration curves are linear over the concentration range of 0.495–200.577 ng/mL of plasma for each analyte. This novel LC–MS-MS method shows satisfactory accuracy and precision and is sufficiently sensitive for the performance of pharmacokinetic studies in humans.

  20. Determination of chlormequat in pig serum and sow milk by LC-MS/MS

    DEFF Research Database (Denmark)

    Poulsen, Mette Erecius; Christensen, Hanne Bjerre; Sørensen, M.T.

    2007-01-01

    reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80...

  1. Evaluation of a screening instrument for essential tremor

    DEFF Research Database (Denmark)

    Lorenz, Delia; Papengut, Frank; Frederiksen, Henrik

    2008-01-01

    To evaluate a screening instrument for essential tremor (ET) consisting of a seven-item questionnaire and a spiral drawing. A total of 2,448 Danish twins aged 70 years or more and a second sample aged 60 years or more (n = 1,684) from a population-based northern German cross-sectional study (Pop....... Definite or probable ET was diagnosed in 104 patients, possible in 86 and other tremors in 98 patients. The sensitivity of the screening instrument was 70.5%, the positive predictive value was 64.9%, the specificity was 68.2%, and the negative predictive value was 73.5%. Tremor severity correlated...... significantly with higher spiral scores and more positive items. More patients were identified by spiral drawing in all tremor groups. The interrater and intrarater reliability for spirals ranged from 0.7 to 0.8 using intraclass coefficient. A cluster analysis revealed that the questionnaire can be reduced...

  2. Analysis of benzodiazepines and their metabolites using DBS cards and LC-MS/MS.

    Science.gov (United States)

    Lee, Heesang; Park, Yujin; Jo, Jiyeong; In, Sangwhan; Park, Yonghoon; Kim, Eunmi; Pyo, Jaesung; Choe, Sanggil

    2015-10-01

    Dried Blood Spot (DBS) has been used a blood extraction method for inherited metabolic disorder screening since 1960s. With introduction of LC-MS/MS, not only DBS could be used to analysis drugs in small blood volume, but in various fields, such as toxicology, drug therapeutic monitoring, drug diagnostic screening, and illicit drugs. In toxicology field, many drugs (e.g. benzodiazepines, acetaminophen, small molecule drugs) have been tested with DBS. Compared with earlier blood extraction methods (SPE and LLE), DBS has lots of advantages; lower blood volume (less than 50μL), shorter analysis time caused by a more concise analysis procedure and lower cost. We optimized the DBS procedure and LC-MS/MS conditions for 18 benzodiazepines, seven benzodiazepine metabolites, and one z-drug (zolpidem) analysis in blood. 30μL of whole blood was spotted on FTA DMPK card C and dried for 2h in a desiccator. A 6-mm disk was punched and vortexed for 1min in a centrifuge tube with 300μL methanol/acetonitrile mixture (1:1, v/v). After evaporation, redissolved in 100μL mobile phase of LC-MS/MS and 5μL was injected. In the analysis for 26 target compounds in blood, all of the method validation parameters - LLOD, LLOQ, accuracy (intra- and inter-assay), and precision (intra- and inter-assay) - were satisfied with method validation criteria, within 15%. The results of matrix effect, recovery, and process efficiency were good. We developed a fast and reliable sample preparation method using DBS for 26 benzodiazepines, benzodiazepine metabolites, and z-drug (zolpidem). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Elemental speciation in biomolecules by LC-ICP-MS with magnetic sector and collision cell instruments

    International Nuclear Information System (INIS)

    Wang, Jin

    1999-01-01

    A methodology that can monitor and identify inorganic elements in biological and environmental systems was developed. Size exclusion chromatography (SEC) separates biomolecules, which are then nebulized by a microconcentric nebulizer. The resulting aerosol is desolved and introduced into either a high resolution ICP-MS device or a quadrupole device with a collision cell. Because of the high sensitivity and spectral resolution and high sample introduction efficiency, many unusual or difficult elements, such as Cr, Se, Cd and U, can be observed at ambient levels bound to proteins in human serum. These measurements are made in only a few minutes without preliminary isolation and preconcentration steps. Serum samples can be titrated with spikes of various elements to determine which proteins bind a given metal and oxidation state. Experiments concerning the effects of breaking disulfide linkages and denaturation on metal binding in proteins were also investigated. Elemental distribution in liver extract was also obtained

  4. Elemental speciation in biomolecules by LC-ICP-MS with magnetic sector and collision cell instruments

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jin [Iowa State Univ., Ames, IA (United States)

    1999-11-08

    A methodology that can monitor and identify inorganic elements in biological and environmental systems was developed. Size exclusion chromatography (SEC) separates biomolecules, which are then nebulized by a microconcentric nebulizer. The resulting aerosol is desolved and introduced into either a high resolution ICP-MS device or a quadrupole device with a collision cell. Because of the high sensitivity and spectral resolution and high sample introduction efficiency, many unusual or difficult elements, such as Cr, Se, Cd and U, can be observed at ambient levels bound to proteins in human serum. These measurements are made in only a few minutes without preliminary isolation and preconcentration steps. Serum samples can be titrated with spikes of various elements to determine which proteins bind a given metal and oxidation state. Experiments concerning the effects of breaking disulfide linkages and denaturation on metal binding in proteins were also investigated. Elemental distribution in liver extract was also obtained.

  5. Data-independent MS/MS quantification of neuropeptides for determination of putative feeding-related neurohormones in microdialysate.

    Science.gov (United States)

    Schmerberg, Claire M; Liang, Zhidan; Li, Lingjun

    2015-01-21

    Food consumption is an important behavior that is regulated by an intricate array of neuropeptides (NPs). Although many feeding-related NPs have been identified in mammals, precise mechanisms are unclear and difficult to study in mammals, as current methods are not highly multiplexed and require extensive a priori knowledge about analytes. New advances in data-independent acquisition (DIA) MS/MS and the open-source quantification software Skyline have opened up the possibility to identify hundreds of compounds and quantify them from a single DIA MS/MS run. An untargeted DIA MS(E) quantification method using Skyline software for multiplexed, discovery-driven quantification was developed and found to produce linear calibration curves for peptides at physiologically relevant concentrations using a protein digest as internal standard. By using this method, preliminary relative quantification of the crab Cancer borealis neuropeptidome (winnowing candidate NPs related to a behavior of interest in a functionally relevant manner, and demonstrates the success of such a UPLC-MS(E) quantification method using the open source software Skyline.

  6. Identification of alkyl dimethylbenzylammonium surfactants in water samples by solid-phase extraction followed by ion trap LC/MS and LC/MS/MS

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2001-01-01

    A novel methodology was developed for the determination of alkyl (C12, C14, and C16) dimethylbenzylammonium chloride (benzalkonium chloride or BAC, Chemical Abstract Service number: 8001-54-5) in water samples. This method is based on solid-phase extraction (SPE) using polymeric cartridges, followed by high-performance liquid chromatography/ion trap mass spectrometry (LC/MS) and tandem mass spectrometry(MS/MS) detection, equipped with an electrospray interface in positive ion mode. Chromatographic separation was achieved for three BAC homologues by using a C18 column and a gradient of acetonitrile/10 millimolar aqueous ammonium formate. Total method recoveries were higher than 71% in different water matrices. The main ions observed by LC/MS were at mass-to-charge ratios (m/z) of 304, 332, and 360, which correspond to the molecular ions of the C12, C14, and C16 alkyl BAC, respectively. The unequivocal structural identification of these compounds in water samples was performed by LC/MS/MS after isolation and subsequent fragmentation of each molecular ion. The main fragmentation observed for the three different homologues corresponded to the loss of the toluyl group in the chemical structure, which leads to the fragment ions at m/z 212, 240, and 268 and a tropylium ion, characteristic of all homologues, at m/z 91. Detection limits for the methodology developed in this work were in the low nanogram-per-liter range. Concentration levels of BAC - ranging from 1.2 to 36.6 micrograms per liter - were found in surface-water samples collected downstream from different wastewater-treatment discharges, thus indicating its input and persistence through the wastewater-treatment process.

  7. Performance of the Modified Mini-Mental State Examination (3MS) in Assessing Specific Cognitive Function in Patients Undergoing Peritoneal Dialysis

    Science.gov (United States)

    Li, Yi; Tian, Xue; Xiong, Zu-Ying; Liao, Jin-Lan; Hao, Li; Liu, Gui-Ling; Ren, Ye-Ping; Wang, Qin; Duan, Li-Ping; Zheng, Zhao-Xia; Quan, Wen-Xiang; Dong, Jie

    2016-01-01

    Purpose While Cognitive impairment (CI) has been identified as an independent risk factors for mortality in patients undergoing peritoneal dialysis (PD), it is inadequately assessed. We evaluated the applicability of the Modified Mini-Mental State Examination (3MS) in assessing specific cognitive function and compared it to a detailed neuropsychological test battery as the reference standard. Methods In this multicentric cross-sectional study, we enrolled 445 clinically stable patients from five PD units, who were undergoing PD for at least 3 months. The 3MS was evaluated for general cognitive function. A detailed neuropsychological battery including domains of immediate memory, delayed memory, executive function, language, and visuospatial ability were evaluated as reference standards. Sensitivity and specificity of the 3MS was determined by using receiver operating characteristic (ROC) analysis. Results The CI prevalence evaluated by 3MS was 23.6%. PD patients with CI performed worse in all cognitive domains. The 3MS correlated well with specific cognitive domains. However, 18.5%, 57.4%, 12.6%, 8.8%, and 41.2% of patients whom were idendified as normal by 3MS still showed executive dysfunction, immediate memory impairment, delayed memory impairment, and language-ability and visuospatial-ability impairment, respectively. The 3MS identified patients having specific cognitive dysfunction with varied extent of diagnostic value, with 0.50, 0.42, 0.35, 0.34, and 0.26 of Youden index in executive function, delayed memory, language ability, immediate memory, and visuospatial ability, respectively. Conclusions The 3MS is not a comprehensive instrument for major cognitive domains in PD patients. It could, however, be used for executive dysfunction and delayed memory impairment screening. PMID:27911914

  8. Two Classifiers Based on Serum Peptide Pattern for Prediction of HBV-Induced Liver Cirrhosis Using MALDI-TOF MS

    Directory of Open Access Journals (Sweden)

    Yuan Cao

    2013-01-01

    Full Text Available Chronic infection with hepatitis B virus (HBV is associated with the majority of cases of liver cirrhosis (LC in China. Although liver biopsy is the reference method for evaluation of cirrhosis, it is an invasive procedure with inherent risk. The aim of this study is to discover novel noninvasive specific serum biomarkers for the diagnosis of HBV-induced LC. We performed bead fractionation/MALDI-TOF MS analysis on sera from patients with LC. Thirteen feature peaks which had optimal discriminatory performance were obtained by using support-vector-machine-(SVM- based strategy. Based on the previous results, five supervised machine learning methods were employed to construct classifiers that discriminated proteomic spectra of patients with HBV-induced LC from those of controls. Here, we describe two novel methods for prediction of HBV-induced LC, termed LC-NB and LC-MLP, respectively. We obtained a sensitivity of 90.9%, a specificity of 94.9%, and overall accuracy of 93.8% on an independent test set. Comparisons with the existing methods showed that LC-NB and LC-MLP held better accuracy. Our study suggests that potential serum biomarkers can be determined for discriminating LC and non-LC cohorts by using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. These two classifiers could be used for clinical practice in HBV-induced LC assessment.

  9. Improved liquid chromatography-MS/MS of heparan sulfate oligosaccharides via chip-based pulsed makeup flow.

    Science.gov (United States)

    Huang, Yu; Shi, Xiaofeng; Yu, Xiang; Leymarie, Nancy; Staples, Gregory O; Yin, Hongfeng; Killeen, Kevin; Zaia, Joseph

    2011-11-01

    Microfluidic chip-based hydrophilic interaction chromatography (HILIC) is a useful separation system for liquid chromatography-mass spectrometry (LC-MS) in compositional profiling of heparan sulfate (HS) oligosaccharides; however, ions observed using HILIC LC-MS are low in charge. Tandem MS of HS oligosaccharide ions with low charge results in undesirable losses of SO(3) from precursor ions during collision induced dissociation. One solution is to add metal cations to stabilize sulfate groups. Another is to add a nonvolatile, polar compound such as sulfolane, a molecule known to supercharge proteins, to produce a similar effect for oligosaccharides. We demonstrate use of a novel pulsed makeup flow (MUF) HPLC-chip. The chip enables controlled application of additives during specified chromatographic time windows and thus minimizes the extent to which nonvolatile additives build up in the ion source. The pulsed MUF system was applied to LC-MS/MS of HS oligosaccharides. Metal cations and sulfolane were tested as additives. The most promising results were obtained for sulfolane, for which supercharging of the oligosaccharide ions increased their signal strengths relative to controls. Tandem MS of these supercharged precursor ions showed decreased abundances of product ions from sulfate losses yet more abundant product ions from backbone cleavages.

  10. CEC-atmospheric pressure ionization MS of pesticides using a surfactant-bound monolithic column.

    Science.gov (United States)

    Gu, Congying; Shamsi, Shahab A

    2010-04-01

    A surfactant bound poly (11-acrylaminoundecanoic acid-ethylene dimethacrylate) monolithic column was simply prepared by in situ co-polymerization of 11-acrylaminoundecanoic acid and ethylene dimethacrylate with 1-propanol, 1,4-butanediol and water as porogens in 100 microm id fused-silica capillary in one step. This column was used in CEC-atmospheric pressure photoionization (APPI)-MS system for separation and detection of N-methylcarbamates pesticides. Numerous parameters are optimized for CEC-APPI-MS. After evaluation of the mobile phase composition, sheath liquid composition and the monolithic capillary outlet position, a fractional factorial design was selected as a screening procedure to identify factors of ionization source parameters, such as sheath liquid flow rate, drying gas flow rate, drying gas temperature, nebulizing gas pressure, vaporizer temperature and capillary voltage, which significantly influence APPI-MS sensitivity. A face-centered central composite design was further utilized to optimize the most significant parameters and predict the best sensitivity. Under optimized conditions, S/Ns around 78 were achieved for an injection of 100 ng/mL of each pesticide. Finally, this CEC-APPI-MS method was successfully applied to the analysis of nine N-methylcarbamates in spiked apple juice sample after solid phase extraction with recoveries in the range of 65-109%.

  11. Determination of Dextromethorphan in Oral Fluid by LC-MS-MS.

    Science.gov (United States)

    Amaratunga, Piyadarsha; Clothier, Morgan; Lorenz Lemberg, Bridget; Lemberg, Dave

    2016-06-01

    Dextromethorphan (DXM) is an antitussive drug found in commonly used nonprescription cold and cough medications. At low doses, DXM is a safe drug that does not produce adverse reactions. However, abuse of DXM has been reported among adolescents and young adults using the drug at higher doses. DXM is not a scheduled drug in the USA, and the primary reason for its abuse is the ease of availability. DXM is available to purchase in the form of over-the-counter cough medications, such as Robitussin(®) and Coricidin(®), or it can be purchased over the Internet in the form of a powder. In this research work, we developed an LC-MS-MS method that can quantify DXM and dextrorphan (DXO) in oral fluid in a high-throughput toxicology laboratory setting. The developed method was validated according to the Scientific Working Group for Forensic Toxicology guidelines. The linear dynamic range was 5-100 ng/mL with a lowest limit of quantitation (LLOQ) of 5.0 ng/mL for DXM and DXO. Overall, the results of the accuracy and the precision values were within the acceptance criteria for both drugs. In addition, selectivity, matrix effect and recovery were calculated for the LC-MS-MS method. Authentic samples (n = 59) were tested to evaluate the applicability of the method. Thirty samples were found to be positive for DXM and DXO and two samples were found to be positive for DXM only. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Analysis of banned veterinary drugs and herbicide residues in shellfish by liquid chromatography-tandem mass spectrometry (LC/MS/MS) and gas chromatography-tandem mass spectrometry (GC/MS/MS)

    International Nuclear Information System (INIS)

    Chang, Geng-Ruei; Chen, Hui-Shan; Lin, Feng-Yi

    2016-01-01

    Seafood safety is a crucial public health concern for consumers. In this study, we applied a validated method to analyze the residue of banned veterinary drugs in shellfish, namely chloramphenicol, malachite green, leucomalachite green, and nitrofuran metabolites; additionally, the QuEChERS method was employed to detect 76 herbicides by LC/MS/MS and GC/MS/MS. In total, 42 shellfish samples, which included hard clams, freshwater clams, and oysters, were collected from aquafarms and production areas in Taiwan during 2012. Our results revealed 3.8 ng/g of chloramphenicol in one hard clam, 19.9–32.1 ng/g of ametryn in two hard clams, 16.1–60.1 ng/g of pendimethalin in four hard clams, and 17.0 ng/g of mefenacet in one oyster, indicating that 19.1% of the samples contained residues from banned veterinary drugs and pesticides. These data can be used to monitor the residue of veterinary drugs and pesticides in aquatic organisms and as a reference for food safety. - Highlights: • A certified method was employed for analyzing residues of banned veterinary drugs and herbicides in shellfish samples. • The trace levels of chloramphenicol, ametryn, pendimethalin were detected in hard clam samples. • For ensuring food safety, continual monitoring of aquatic products is necessary.

  13. Structural Feature Ions for Distinguishing N- and O-Linked Glycan Isomers by LC-ESI-IT MS/MS

    Science.gov (United States)

    Everest-Dass, Arun V.; Abrahams, Jodie L.; Kolarich, Daniel; Packer, Nicolle H.; Campbell, Matthew P.

    2013-06-01

    Glycomics is the comprehensive study of glycan expression in an organism, cell, or tissue that relies on effective analytical technologies to understand glycan structure-function relationships. Owing to the macro- and micro-heterogeneity of oligosaccharides, detailed structure characterization has required an orthogonal approach, such as a combination of specific exoglycosidase digestions, LC-MS/MS, and the development of bioinformatic resources to comprehensively profile a complex biological sample. Liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) has emerged as a key tool in the structural analysis of oligosaccharides because of its high sensitivity, resolution, and robustness. Here, we present a strategy that uses LC-ESI-MS/MS to characterize over 200 N- and O-glycans from human saliva glycoproteins, complemented by sequential exoglycosidase treatment, to further verify the annotated glycan structures. Fragment-specific substructure diagnostic ions were collated from an extensive screen of the literature available on the detailed structural characterization of oligosaccharides and, together with other specific glycan structure feature ions derived from cross-ring and glycosidic-linkage fragmentation, were used to characterize the glycans and differentiate isomers. The availability of such annotated mass spectrometric fragmentation spectral libraries of glycan structures, together with such substructure diagnostic ions, will be key inputs for the future development of the automated elucidation of oligosaccharide structures from MS/MS data.

  14. Practicing a musical instrument in childhood is associated with enhanced verbal ability and nonverbal reasoning.

    Science.gov (United States)

    Forgeard, Marie; Winner, Ellen; Norton, Andrea; Schlaug, Gottfried

    2008-01-01

    In this study we investigated the association between instrumental music training in childhood and outcomes closely related to music training as well as those more distantly related. Children who received at least three years (M = 4.6 years) of instrumental music training outperformed their control counterparts on two outcomes closely related to music (auditory discrimination abilities and fine motor skills) and on two outcomes distantly related to music (vocabulary and nonverbal reasoning skills). Duration of training also predicted these outcomes. Contrary to previous research, instrumental music training was not associated with heightened spatial skills, phonemic awareness, or mathematical abilities. While these results are correlational only, the strong predictive effect of training duration suggests that instrumental music training may enhance auditory discrimination, fine motor skills, vocabulary, and nonverbal reasoning. Alternative explanations for these results are discussed.

  15. Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis.

    Science.gov (United States)

    Kievit, A J; Dobbe, J G G; Streekstra, G J; Blankevoort, L; Schafroth, M U

    2018-06-01

    Malalignment of implants is a major source of failure during total knee arthroplasty. To achieve more accurate 3D planning and execution of the osteotomy cuts during surgery, the Signature (Biomet, Warsaw) patient-specific instrumentation (PSI) was used to produce pin guides for the positioning of the osteotomy blocks by means of computer-aided manufacture based on CT scan images. The research question of this study is: what is the transfer accuracy of osteotomy planes predicted by the Signature PSI system for preoperative 3D planning and intraoperative block-guided pin placement to perform total knee arthroplasty procedures? The transfer accuracy achieved by using the Signature PSI system was evaluated by comparing the osteotomy planes predicted preoperatively with the osteotomy planes seen intraoperatively in human cadaveric legs. Outcomes were measured in terms of translational and rotational errors (varus, valgus, flexion, extension and axial rotation) for both tibia and femur osteotomies. Average translational errors between the osteotomy planes predicted using the Signature system and the actual osteotomy planes achieved was 0.8 mm (± 0.5 mm) for the tibia and 0.7 mm (± 4.0 mm) for the femur. Average rotational errors in relation to predicted and achieved osteotomy planes were 0.1° (± 1.2°) of varus and 0.4° (± 1.7°) of anterior slope (extension) for the tibia, and 2.8° (± 2.0°) of varus and 0.9° (± 2.7°) of flexion and 1.4° (± 2.2°) of external rotation for the femur. The similarity between osteotomy planes predicted using the Signature system and osteotomy planes actually achieved was excellent for the tibia although some discrepancies were seen for the femur. The use of 3D system techniques in TKA surgery can provide accurate intraoperative guidance, especially for patients with deformed bone, tailored to individual patients and ensure better placement of the implant.

  16. Application of HRAM screening and LC-MS/MS confirmation of active pharmaceutical ingredient in "natural" herbal supplements.

    Science.gov (United States)

    Pascali, Jennifer P; Fais, Paolo; Vaiano, Fabio; Bertol, Elisabetta

    2018-05-01

    The growing market of herbal remedies worldwide could pose severe problems to consumers' health due to the possible presence of potentially harmful, undeclared synthetic substances or analogues of prescription drugs. The present work shows a simple but effective approach to unequivocally identify synthetic anorectic compounds in allegedly 'natural' herbal extracts, by exploiting liquid chromatography/time of flight (Q-TOF LC/MS) technology coupled to liquid chromatography/triple quadrupole (LC-MS/MS) confirmation and quantitation. The procedure was applied to five tea herbal extracts and pills sold as coadjutant for weigh loss. The method exploited liquid-liquid sample extraction (LLE) and separation in a C18 (2.1mm×150mm, 1.8μm) column. QTOF acquisitions were carried out both in scan mode and all ion MS/MS mode and results were obtained after search against ad hoc prepared library. Sibutramine, 4-hydroxyamphetamine, caffeine and theophylline were preliminary identified samples. Confirmation and quantitation of the preliminary identified compounds were obtained in LC-MS/MS after preparation of appropriated standards. Sibutramine, caffeine and theophylline were finally confirmed and quantitate. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Vitamin D Levels Predict Multiple Sclerosis Progression

    Science.gov (United States)

    ... Research Matters NIH Research Matters February 3, 2014 Vitamin D Levels Predict Multiple Sclerosis Progression Among people ... sclerosis (MS), those with higher blood levels of vitamin D had better outcomes during 5 years of ...

  18. Characterization of a catalyst-based conversion technique to measure total particulate nitrogen and organic carbon and comparison to a particle mass measurement instrument

    Science.gov (United States)

    Stockwell, Chelsea E.; Kupc, Agnieszka; Witkowski, Bartłomiej; Talukdar, Ranajit K.; Liu, Yong; Selimovic, Vanessa; Zarzana, Kyle J.; Sekimoto, Kanako; Warneke, Carsten; Washenfelder, Rebecca A.; Yokelson, Robert J.; Middlebrook, Ann M.; Roberts, James M.

    2018-05-01

    electrospray ionization source of a quadrupole mass spectrometer (PILS-ESI/MS) sampling in the negative-ion mode. We obtain excellent correlations (R2 = 0.99) of particle mass measured as Nr with PILS-ESI/MS measurements converted to the corresponding particle anion mass (e.g., nitrate, sulfate, and chloride). The Nr and PILS-ESI/MS are shown to agree to within ˜ 6 % for particle mass loadings of up to 120 µg m-3. Consideration of all the sources of error in the PILS-ESI/MS technique yields an overall uncertainty of ±20 % for these single-component particle streams. These results demonstrate the Nr system is a reliable direct particle mass measurement technique that differs from other particle instrument calibration techniques that rely on knowledge of particle size, shape, density, and refractive index.

  19. Instrumentation requirements from the user's view

    International Nuclear Information System (INIS)

    Harsha, P.T.

    1988-01-01

    The use of combustor diagnostics is considered from the point of view of demonstration of performance of an airbreathing hypersonic engine. The basic need is seen to be that of providing the data necessary to verify performance predictions for the engine as installed in the airplane. This necessitates the use of a diagnostics capability that can provide the inputs required by the computational analyses that will be used to assess this performance. Because of the cost of ground test facilities, a premium is placed on measurement technique reliability and redundancy of instrumentation. A mix of nonintrusive optical techniques and probe-based measurements is seen to be the best approach using current diagnostics capability; one such instrument mix is outlined for a ramjet/scramjet test program. 11 references

  20. Multiclass determination and confirmation of antibiotic residues in honey using LC-MS/MS.

    Science.gov (United States)

    Lopez, Mayda I; Pettis, Jeffery S; Smith, I Barton; Chu, Pak-Sin

    2008-03-12

    A multiclass method has been developed for the determination and confirmation in honey of tetracyclines (chlortetracycline, doxycycline, oxytetracycline, and tetracycline), fluoroquinolones (ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, and sarafloxacin), macrolides (tylosin), lincosamides (lincomycin), aminoglycosides (streptomycin), sulfonamides (sulfathiazole), phenicols (chloramphenicol), and fumagillin residues using liquid chromatography tandem mass spectrometry (LC-MS/MS). Erythromycin (a macrolide) and monensin (an ionophore) can be detected and confirmed but not quantitated. Honey samples (approximately 2 g) are dissolved in 10 mL of water and centrifuged. An aliquot of the supernatant is used to determine streptomycin. The remaining supernatant is filtered through a fine-mesh nylon fabric and cleaned up by solid phase extraction. After solvent evaporation and sample reconstitution, 15 antibiotics are assayed by LC-MS/MS using electrospray ionization (ESI) in positive ion mode. Afterward, chloramphenicol is assayed using ESI in negative ion mode. The method has been validated at the low part per billion levels for most of the drugs with accuracies between 65 and 104% and coefficients of variation less than 17%. The evaluation of matrix effects caused by honey of different floral origin is presented.

  1. Methods in endogenous steroid profiling - A comparison of gas chromatography mass spectrometry (GC-MS) with supercritical fluid chromatography tandem mass spectrometry (SFC-MS/MS).

    Science.gov (United States)

    Teubel, Juliane; Wüst, Bernhard; Schipke, Carola G; Peters, Oliver; Parr, Maria Kristina

    2018-06-15

    In various fields of endocrinology, the determination of steroid hormones synthesised by the human body plays an important role. Research on central neurosteroids has been intensified within the last years, as they are discussed as biomarkers for various cognitive disorders. Their concentrations in cerebrospinal fluid (CSF) are considered to be regulated independently from peripheral fluids. For that reason, the challenging matrix CSF becomes a very interesting specimen for analysis. Concentrations are expected to be very low and available amount of CSF is limited. Thus, a comprehensive method for very sensitive quantification of a set of analytes as large as possible in one analytical aliquot is desired. However, high structural similarities of the selected panel of 51 steroids and steroid sulfates, including numerous isomers, challenges achievement of chromatographic selectivity. Since decades the analysis of endogenous steroids in various body fluids is mainly performed by gas chromatography (GC) coupled to (tandem) mass spectrometry (MS(/MS)). Due to the structure of the steroids of interest, derivatisation is performed to meet the analytical requirements for GC-MS(/MS). Most of the laboratories use a two-step derivatisation in multi-analyte assays that was already published in the 1980s. However, for some steroids this elaborate procedure yields multiple isomeric derivatives. Thus, some laboratories utilize (ultra) high performance liquid chromatography ((U)HPLC)-MS/MS as alternative but, even UHPLC is not able to separate some of the isomeric pairs. Supercritical fluid chromatography (SFC) as an orthogonal separation technique to GC and (U)HPLC may help to overcome these issues. Within this project the two most promising methods for endogenous steroid profiling were investigated and compared: the "gold standard" GC-MS and the orthogonal separation technique SFC-MS/MS. Different derivatisation procedures for gas chromatographic detection were explored and the

  2. A software simulator for the SPICA Safari instrument

    International Nuclear Information System (INIS)

    Naylor, D A; Hayton, D J; Lindner, J V; Sadeghi, B

    2011-01-01

    A software simulator that has been developed for the Safari instrument proposed for the SPace Infrared telescope for Cosmology and Astrophysics (SPICA) mission is presented. The simulator can ingest a range of realistic input spectra and, following a thorough radiative transfer analysis, calculates the power reaching the detector as a function of the optical path difference within the interferometer. The simulator is modular in design so that it can be easily modified to ingest test data as they become available. The simulator will not only find use during the design phase of the Safari instrument, but also during ground performance verification campaigns of the flight model. Through validation of the simulator on ground test data, it will be possible to predict accurately the in-orbit performance of the Safari instrument

  3. Ion mobility spectrometer / mass spectrometer (IMS-MS).

    Energy Technology Data Exchange (ETDEWEB)

    Hunka Deborah Elaine; Austin, Daniel E.

    2005-07-01

    The use of Ion Mobility Spectrometry (IMS) in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400). Combining Ion Mobility Spectrometry (IMS) with Mass Spectrometry (MS) is described. The IMS-MS combination overcomes several limitations present in simple IMS systems. Ion mobility alone is insufficient to identify an unknown chemical agent. Collision cross section, upon which mobility is based, is not sufficiently unique or predictable a priori to be able to make a confident peak assignment unless the compounds present are already identified. Molecular mass, on the other hand, is much more readily interpreted and related to compounds. For a given compound, the molecular mass can be determined using a pocket calculator (or in one's head) while a reasonable value of the cross-section might require hours of computation time. Thus a mass spectrum provides chemical specificity and identity not accessible in the mobility spectrum alone. In addition, several advanced mass spectrometric methods, such as tandem MS, have been extensively developed for the purpose of molecular identification. With an appropriate mass spectrometer connected to an ion mobility spectrometer, these advanced identification methods become available, providing greater characterization capability.

  4. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  5. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  6. Characterization of Proteins Present in Isolated Senile Plaques from Alzheimer's Diseased Brains by MALDI-TOF MS with MS/MS.

    Science.gov (United States)

    Kelley, Andrea R; Perry, George; Bach, Stephan B H

    2018-04-18

    The increase of insoluble senile plaques in the brain is a primary hallmark of Alzheimer's disease. The usefulness of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) with tandem MS for the characterization of senile plaques from AD brains and the relevance of the components identified to furthering AD research using MS is discussed. Thirty-three components were reproducibly observed within tryptic aliquots of senile plaques from two different AD brains after sample preparation optimization. Additionally, this is one of the first accounts of LIFT being utilized for the direct sequencing of peptides from isolated senile plaques. While many of the species observed coisolated within senile plaques have been linked to AD etiology, if only speculatively, this is the first instance that many of them have been demonstrated to be a part of the plaques themselves. This work is the first step in determining the potential roles that the species may have in the aggregation or proliferation of the plaques.

  7. Short Communication: Testosterone Measured with an Automatic Immunoassay Compares Reasonbly Well to Results Obtained by LC-MS/MS

    DEFF Research Database (Denmark)

    Knudsen, Cindy Søndersø; Højskov, Carsten Schriver; Møller, Holger Jon

    2016-01-01

    Background: Previous studies have reported problems measuring testosterone with immunological assays. Here we explore an automatic second generation immunoassay compared to a LC-MS/MS method. Methods: We collected blood samples from 76 women and measured testosterone, progesterone, gender...... hormonebinding globulin (SHBG), and albumin employing Cobas e601/c501. Testosterone, androstenedione (andro), dehydroepiandrosterone sulphate (DHEAS), and 17-hydroxyprogesterone (17-OHP) concentrations were measured employing LC-MS/MS. We evaluated the difference between testosterone measured by the two methods...... and examined the potential interference from the selected steroids and bindings proteins. Results: Testosterone concentrations measured by the two methods yielded: Cobas e601 = 1.240 x (LC-MS/MS) - 0.197, r = 0.84, for testosterone concentrations between 0.22 - 4.9 nmol/L. A positive correlation was observed...

  8. Metabolism of the new psychoactive substances N,N-diallyltryptamine (DALT) and 5-methoxy-DALT and their detectability in urine by GC-MS, LC-MSn, and LC-HR-MS-MS.

    Science.gov (United States)

    Michely, Julian A; Helfer, Andreas G; Brandt, Simon D; Meyer, Markus R; Maurer, Hans H

    2015-10-01

    N,N-Diallyltryptamine (DALT) and 5-methoxy-DALT (5-MeO-DALT) are synthetic tryptamine derivatives commonly referred to as so-called new psychoactive substances (NPS). They have psychoactive effects that may be similar to those of other tryptamine derivatives. The objectives of this work were to study the metabolic fate and detectability, in urine, of DALT and 5-MeO-DALT. For metabolism studies, rat urine obtained after high-dose administration was prepared by precipitation and analyzed by liquid chromatography-high-resolution mass spectrometry (LC-HR-MS-MS). On the basis of the metabolites identified, several aromatic and aliphatic hydroxylations, N-dealkylation, N-oxidation, and combinations thereof are proposed as the main metabolic pathways for both compounds. O-Demethylation of 5-MeO-DALT was also observed, in addition to extensive glucuronidation or sulfation of both compounds after phase I transformation. The cytochrome P450 (CYP) isoenzymes predominantly involved in DALT metabolism were CYP2C19, CYP2D6, and CYP3A4; those mainly involved in 5-MeO-DALT metabolism were CYP1A2, CYP2C19, CYP2D6, and CYP3A4. For detectability studies, rat urine was screened by GC-MS, LC-MS(n), and LC-HR-MS-MS after administration of low doses. LC-MS(n) and LC-HR-MS-MS were deemed suitable for monitoring consumption of both compounds. The most abundant targets were a ring hydroxy metabolite of DALT, the N,O-bis-dealkyl metabolite of 5-MeO-DALT, and their glucuronides. GC-MS enabled screening of DALT by use of its main metabolites only.

  9. Screening of veterinary drug residues in food by LC-MS/MS. Background and challenges.

    Science.gov (United States)

    Delatour, Thierry; Racault, Lucie; Bessaire, Thomas; Desmarchelier, Aurélien

    2018-04-01

    Regulatory agencies and government authorities have established maximum residue limits (MRL) in various food matrices of animal origin for supporting governments and food operators in the monitoring of veterinary drug residues in the food chain, and ultimately in the consumer's plate. Today, about 200 veterinary drug residues from several families, mainly with antibiotic, antiparasitic or antiinflammatory activities, are regulated in a variety of food matrices such as milk, meat or egg. This article provides a review of the regulatory framework in milk and muscle including data from Codex Alimentarius, Europe, the U.S.A., Canada and China for about 220 veterinary drugs. The article also provides a comprehensive overview of the challenge for food control, and emphasizes the pivotal role of liquid chromatography-mass spectrometry (LC-MS), either in tandem with quadrupoles (LC-MS/MS) or high resolution MS (LC-HRMS), for ensuring an adequate consumer protection combined with an affordable cost. The capability of a streamlined LC-MS/MS platform for screening 152 veterinary drug residues in a broad range of raw materials and finished products is highlighted in a production line perspective. The rationale for a suite of four methods intended to achieve appropriate performance in terms of scope and sensitivity is presented. Overall, the platform encompasses one stream for the determination of 105 compounds in a run (based on acidic QuEChERS-like), plus two streams for 23 β-lactams (alkaline QuEChERS-like) and 10 tetracyclines (low-temperature partitioning), respectively, and a dedicated stream for 14 aminoglycosides (molecularly-imprinted polymer).

  10. Separation and quantitation of radionuclides in Hanford environmental and waste tank samples using IC-ICP/MS techniques

    International Nuclear Information System (INIS)

    Farmer, O.T. III; Smith, M.R.; Wyse, E.J.; Barinage, C.J.; Koppenaal, D.W.

    1996-01-01

    The use of shielded ICP/MS instrumentation to characterize radioactive material has seen marked growth over the past few years. With a lower limit detection now in the fg/mL range for newer units, ICP/MS has become the method of choice for many studies requiring rapid, isotopic analysis of both stable elements and radionuclides with half-lives greater than 102-103 years. However, despite its sensitivity and versatility, ICP/MS has heretofore had some notable limitations in certain radiological applications. For example, Hanford waste tank samples contain a variety of nuclides with altered isotopic abundances, which complicate identification of these nuclides. Even if a nuclide can be identified, conventional quantitation using vendor-supplied software assumes natural, or knowledge of, isotopic abundance. Difficult sample matrices like those obtained from the Hanford tanks can further complicate interpretation and quantitation. On-line ion chromatography (IC) has been recently employed to mitigate some these problems. By sequentially separating elements, isobars can be resolved, thereby permitting the unequivocal determination of isotopic abundances. But even though the technique resolves isobaric interferences and is effective in reducing matrix problems, IC does not easily lend itself to quantitation. Internal standards, which are crucial for quantitation during a prolonged ICP/MS analysis with varying eluant matrices, are separated or affected as any indigenous element is using standard IC methodology

  11. Predicting Team Performance through Human Behavioral Sensing and Quantitative Workflow Instrumentation

    Science.gov (United States)

    2016-07-27

    3. Fig. 3. An illustration of viewport instrumentation. The game client (left) is viewing a portion of the scenario video , whose viewport...in the video and the x-axis representing the number of minutes elapsed since the start of the game . Similarly, Fig. 5 illustrates the teams...courses of action strength) and reflects the overall strategy for how they decide to approach the game ( aggressive to risk-averse). 5.3 Team

  12. The role of EBV in MS pathogenesis

    DEFF Research Database (Denmark)

    Christensen, Tove

    2006-01-01

    Environmental factors operate on a background of genetic susceptibility in the pathogenesis of MS. Human herpesviruses, notably Epstein-Barr virus (EBV), and human endogenous retroviruses are factors associated with MS. EBV association is found in epidemiological surveys where late EBV infection...... confers a higher risk of MS, and EBV reactivation also appears to be linked to disease activity in early MS. MS patients have elevated anti-EBV antibody responses, both in serum and cerebrospinal fluid. Molecular mimicry is found between certain EBV and myelin epitopes in the cell-mediated immune response....... EBV cannot stand alone as a causal factor of MS, but is likely to play an indirect role as an activator of the underlying disease process....

  13. Evaluation of laser diode thermal desorption (LDTD) coupled with tandem mass spectrometry (MS/MS) for support of in vitro drug discovery assays: increasing scope, robustness and throughput of the LDTD technique for use with chemically diverse compound libraries.

    Science.gov (United States)

    Beattie, Iain; Smith, Aaron; Weston, Daniel J; White, Peter; Szwandt, Simon; Sealey, Laura

    2012-02-05

    Within the drug discovery environment, the key process in optimising the chemistry of a structural series toward a potential drug candidate is the design, make and test cycle, in which the primary screens consist of a number of in vitro assays, including metabolic stability, cytochrome P450 inhibition, and time-dependent inhibition assays. These assays are often carried out using multiple drug compounds with chemically diverse structural features, often in a 96 well-plate format for maximum time-efficiency, and are supported using rapid liquid chromatographic (LC) sample introduction with a tandem mass spectrometry (MS/MS) selected reaction monitoring (SRM) endpoint, taking around 6.5 h per plate. To provide a faster time-to-decision at this critical point, there exists a requirement for higher sample throughput and a robust, well-characterized analytical alternative. This paper presents a detailed evaluation of laser diode thermal desorption (LDTD), a relatively new ambient sample ionization technique, for compound screening assays. By systematic modification of typical LDTD instrumentation and workflow, and providing deeper understanding around overcoming a number of key issues, this work establishes LDTD as a practical, rapid alternative to conventional LC-MS/MS in drug discovery, without need for extensive sample preparation or expensive, scope-limiting internal standards. Analysis of both the five and three cytochrome P450 competitive inhibition assay samples by LDTD gave improved sample throughput (0.75 h per plate) and provided comparable data quality as the IC₅₀ values obtained were within 3 fold of those calculated from the LC-MS/MS data. Additionally when applied generically to a chemically diverse library of over 250 proprietary compounds from the AstraZeneca design, make and test cycle, LDTD demonstrated a success rate of 98%. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Wide-scope screening of pesticides in fruits and vegetables using information-dependent acquisition employing UHPLC-QTOF-MS and automated MS/MS library searching.

    Science.gov (United States)

    Wang, Zhibin; Cao, Yanzhong; Ge, Na; Liu, Xiaomao; Chang, Qiaoying; Fan, Chunlin; Pang, Guo-Fang

    2016-11-01

    This paper presents an application of ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) for simultaneous screening and identification of 427 pesticides in fresh fruit and vegetable samples. Both full MS scan mode for quantification, and an artificial-intelligence-based product ion scan mode information-dependent acquisition (IDA) providing automatic MS to MS/MS switching of product ion spectra for identification, were conducted by one injection. A home-in collision-induced-dissociation all product ions accurate mass spectra library containing more than 1700 spectra was developed prior to actual application. Both qualitative and quantitative validations of the method were carried out. The result showed that 97.4 % of the pesticides had the screening detection limit (SDL) less than 50 μg kg -1 and more than 86.7 % could be confirmed by accurate MS/MS spectra embodied in the home-made library. Meanwhile, calibration curves covering two orders of magnitude were performed, and they were linear over the concentration range studied for the selected matrices (from 5 to 500 μg kg -1 for most of the pesticides). Recoveries between 80 and 110 % in four matrices (apple, orange, tomato, and spinach) at two spiked levels, 10 and 100 μg kg -1 , was 88.7 or 86.8 %. Furthermore, the overall relative standard deviation (RSD, n = 12) for 94.3 % of the pesticides in 10 μg kg -1 and 98.1 % of the pesticides in 100 μg kg -1 spiked levels was less than 20 %. In order to validate the suitability for routine analysis, the method was applied to 448 fruit and vegetable samples purchased in different local markets. The results show 83.3 % of the analyzed samples have positive findings (higher than the limits of identification and quantification), and 412 commodity-pesticide combinations are identified in our scope. The approach proved to be a cost-effective, time-saving and powerful strategy for routine large

  15. Estimating pushrim temporal and kinetic measures using an instrumented treadmill during wheelchair propulsion: A concurrent validity study.

    Science.gov (United States)

    Gagnon, Dany H; Jouval, Camille; Chénier, Félix

    2016-06-14

    Using ground reaction forces recorded while propelling a manual wheelchair on an instrumented treadmill may represent a valuable alternative to using an instrumented pushrim to calculate temporal and kinetic parameters during propulsion. Sixteen manual wheelchair users propelled their wheelchair equipped with instrumented pushrims (i.e., SMARTWheel) on an instrumented dual-belt treadmill set a 1m/s during a 1-minute period. Spatio-temporal (i.e., duration of the push and recovery phase) and kinetic measures (i.e. propulsive moments) were calculated for 20 consecutive strokes for each participant. Strong associations were confirmed between the treadmill and the instrumented pushrim for the mean duration of the push phase (r=0.98) and of the recovery phase (r=0.99). Good agreement between these two measurement instruments was also confirmed with mean differences of only 0.028s for the push phase and 0.012s for the recovery phase. Strong associations were confirmed between the instrumented wheelchair pushrim and treadmill for mean (r=0.97) and peak (r=0.96) propulsive moments. Good agreement between these two measurement instruments was also confirmed with mean differences of 0.50Nm (mean moment) and 0.71Nm (peak moment). The use of a dual-belt instrumented treadmill represents an alternative to characterizing temporal parameters and propulsive moments during manual wheelchair propulsion. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Instrumentation for mass spectrometry: 1997

    Energy Technology Data Exchange (ETDEWEB)

    McLuckey, S.A.

    1997-08-01

    All mass spectrometry experiments involve the manipulation of material, an interface with the mass spectrometer, ionization, ion manipulation/analysis, detection and data collection/reduction. Each of these elements involve instrumentation. The wide range of species now amenable to mass spectrometry and the diverse areas of physical science in which it plays a role have led to a seemingly unlimited array of instrumental combinations. However, only a limited number of mass analyzers, and their combinations, dominate. The dominant analyzers include time-of-flight, Fourier transform ion cyclotron resonance, the Paul trap, the mass filter, and the sector mass spectrometer. Why there are so few (or so many, depending upon one`s point of view) can be understood upon consideration of a set of mass analyzer figures of merit. These include mass resolution, mass accuracy, mass range, dynamic range, abundance sensitivity, precision, efficiency, speed, MS{sup n} capability, compatibility with the ionizer, cost, and size. The most appropriate form of mass spectrometry is determined by the priorities of the particular measurement placed on the various mass analyzer characteristics and the relative strengths of the analyzers in meeting the requirements. Each of the analyzer types has a unique set of figures of merit that makes it optimally suited for particular applications. This paper discusses these figures of merit, provides data illustrating recent developments for each analyzer type, and gives the figures of merit of each type of analyzer as they stand in 1997. 101 refs., 24 figs.

  17. HPLC-MS technique in radiopharmaceutical research (the quality control of 18F-2-fluorodeoxyglucose as an example)

    International Nuclear Information System (INIS)

    Macasek, F.

    2001-01-01

    Application of radiopharmaceuticals puts increasing demands on their quality control, considering the short half-times, high specific activities (auto-radiolytic effects), and general quality (chemical purity, apyrogenity and sterility) of pharmacy. Mostly, the radioanalytical control consists of application of several separation and instrumental analytical techniques. In this paper, perspective of the hyphenated HPLC and MS techniques is demonstrated on the example of one of the most spread radiopharmaceutical, 2-[ 18 F]fluoro-2-deoxy-D-glucose (further as FDG). In this work, a liquid chromatography/refractive index detector/radiometric detector/mass spectrometric detector combination (HPLC/RID/RAD/MSD) was used for development of a complex routine technique. Optimization of HPLC/MS analysis was performed investigating the electrospray ionization (ESI) analytical signal of mass spectrometer as a function of various eluent composition (see this book, p. 39). Some results, illustrating the glucose and FDG ESI-MS, and also composition of FDG after autoradiolysis, which were obtained either by a TOF Mariner (Perkin Elmer) mass-spectrometer and Agilent 1100 HPLC-MS equipment with quadrupole MS detector are discussed. They give evidence of admixtures and radiolytic formation of deoxyglucose, deoxychloroglucose, erythrose, erytritol, gluconic acid, lactose, raffinose, saccharic acid, sorbitol/[ 19 F]FDG, xylitol, and also univalent ions of C 6 H 10 O 7 F.H 2 O and C 6 H 12 O 8 compounds. The results indicate that the emerging demands on radiopharmaceuticals quality control can be fulfilled in-time only by the radio-HPLC technique developed by the help of a tandem mass-spectrometric detector. (authors)

  18. Determination of 48 fragrance allergens in toys using GC with ion trap MS/MS.

    Science.gov (United States)

    Lv, Qing; Zhang, Qing; Li, Wentao; Li, Haiyu; Li, Pi; Ma, Qiang; Meng, Xianshuang; Qi, Meiling; Bai, Hua

    2013-11-01

    This paper presents a method for the simultaneous determination of 48 fragrance allergens in four types of toys (plastic toys, play clays, plush toys, and paper toys) based on GC with ion trap MS/MS. Compared with single-stage MS, MS/MS is superior in terms of the qualification and quantification of a large range of compounds in complicated matrices. Procedures for extraction and purification were optimized for each toy type. The method proved to be linear over a wide range of concentrations for all analytes with correlation coefficients between 0.9768 and 0.9999. Validation parameters, namely, LODs and LOQs, ranged from 0.005-5.0 and from 0.02-20 mg/kg, respectively. Average recoveries of target compounds (spiked at three concentration levels) were in the range of 79.5-109.1%. Intraday and interday repeatabilities of the proposed method varied from 0.7-10.5% and from 3.1-13.4%, respectively. The proposed method was used to monitor fragrance allergens in commercial toy products. Our findings indicate that this method is an accurate and effective technique for analyzing fragrance allergens in materials composed of complex components. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Ellagitannin composition of blackberry as determined by HPLC-ESI-MS and MALDI-TOF-MS.

    Science.gov (United States)

    Hager, Tiffany J; Howard, Luke R; Liyanage, Rohana; Lay, Jackson O; Prior, Ronald L

    2008-02-13

    Blackberries ( Rubus sp.) were evaluated by high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) and matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF-MS) to identify the ellagitannins present in flesh, torus (receptacle tissue), and seeds. Most ellagitannins were present (or detectable) only in seed tissues. Ellagitannins identified by HPLC-ESI-MS in the seeds included pedunculagin, casuarictin/potentillin, castalagin/vescalagin, lambertianin A/sanguiin H-6, lambertianin C, and lambertianin D. For several of the ellagitannins, isomeric separation was also obtained. The MALDI-TOF-MS analysis was primarily utilized to evaluate and identify high molecular mass (>1000 Da) ellagitannins. The MALDI analysis verified the presence of the ellagitannins identified by HPLC-ESI-MS including lambertianin A/sanguiin H-6, lambertianin C, and lambertianin D, but the analysis also indicated the presence of several other compounds that were most likely ellagitannins based on the patterns observed in the masses (i.e., loss or addition of a gallic acid moiety to a known ellagitannin). This study determined the presence of several possible isomeric forms of ellagitannins previously unidentified in fruit and presents a possible analytical HPLC method for the analysis of the major ellagitannins present in the fruit.

  20. Matrix effects break the LC behavior rule for analytes in LC-MS/MS analysis of biological samples.

    Science.gov (United States)

    Fang, Nianbai; Yu, Shanggong; Ronis, Martin Jj; Badger, Thomas M

    2015-04-01

    High-performance liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) are generally accepted as the preferred techniques for detecting and quantitating analytes of interest in biological matrices on the basis of the rule that one chemical compound yields one LC-peak with reliable retention time (Rt.). However, in the current study, we have found that under the same LC-MS conditions, the Rt. and shape of LC-peaks of bile acids in urine samples from animals fed dissimilar diets differed significantly among each other. To verify this matrix effect, 17 authentic bile acid standards were dissolved in pure methanol or in methanol containing extracts of urine from pigs consuming either breast milk or infant formula and analyzed by LC-MS/MS. The matrix components in urine from piglets fed formula significantly reduced the LC-peak Rt. and areas of bile acids. This is the first characterization of this matrix effect on Rt. in the literature. Moreover, the matrix effect resulted in an unexpected LC behavior: one single compound yielded two LC-peaks, which broke the rule of one LC-peak for one compound. The three bile acid standards which exhibited this unconventional LC behavior were chenodeoxycholic acid, deoxycholic acid, and glycocholic acid. One possible explanation for this effect is that some matrix components may have loosely bonded to analytes, which changed the time analytes were retained on a chromatography column and interfered with the ionization of analytes in the MS ion source to alter the peak area. This study indicates that a comprehensive understanding of matrix effects is needed towards improving the use of HPLC and LC-MS/MS techniques for qualitative and quantitative analyses of analytes in pharmacokinetics, proteomics/metabolomics, drug development, and sports drug testing, especially when LC-MS/MS data are analyzed by automation software where identification of an analyte is based on its exact molecular weight and Rt

  1. In Situ Carbon Isotope Analysis by Laser Ablation MC-ICP-MS.

    Science.gov (United States)

    Chen, Wei; Lu, Jue; Jiang, Shao-Yong; Zhao, Kui-Dong; Duan, Deng-Fei

    2017-12-19

    Carbon isotopes have been widely used in tracing a wide variety of geological and environmental processes. The carbon isotope composition of bulk rocks and minerals was conventionally analyzed by isotope ratio mass spectrometry (IRMS), and, more recently, secondary ionization mass spectrometry (SIMS) has been widely used to determine carbon isotope composition of carbon-bearing solid materials with good spatial resolution. Here, we present a new method that couples a RESOlution S155 193 nm laser ablation system with a Nu Plasma II MC-ICP-MS, with the aim of measuring carbon isotopes in situ in carbonate minerals (i.e., calcite and aragonite). Under routine operating conditions for δ 13 C analysis, instrumental bias generally drifts by 0.8‰-2.0‰ in a typical analytical session of 2-3 h. Using a magmatic calcite as the standard, the carbon isotopic composition was determined for a suite of calcite samples with δ 13 C values in the range of -6.94‰ to 1.48‰. The obtained δ 13 C data are comparable to IRMS values. The combined standard uncertainty for magmatic calcite is ICP-MS can serve as an appropriate method to analyze carbon isotopes of carbonate minerals in situ.

  2. IsoMS: automated processing of LC-MS data generated by a chemical isotope labeling metabolomics platform.

    Science.gov (United States)

    Zhou, Ruokun; Tseng, Chiao-Li; Huan, Tao; Li, Liang

    2014-05-20

    A chemical isotope labeling or isotope coded derivatization (ICD) metabolomics platform uses a chemical derivatization method to introduce a mass tag to all of the metabolites having a common functional group (e.g., amine), followed by LC-MS analysis of the labeled metabolites. To apply this platform to metabolomics studies involving quantitative analysis of different groups of samples, automated data processing is required. Herein, we report a data processing method based on the use of a mass spectral feature unique to the chemical labeling approach, i.e., any differential-isotope-labeled metabolites are detected as peak pairs with a fixed mass difference in a mass spectrum. A software tool, IsoMS, has been developed to process the raw data generated from one or multiple LC-MS runs by peak picking, peak pairing, peak-pair filtering, and peak-pair intensity ratio calculation. The same peak pairs detected from multiple samples are then aligned to produce a CSV file that contains the metabolite information and peak ratios relative to a control (e.g., a pooled sample). This file can be readily exported for further data and statistical analysis, which is illustrated in an example of comparing the metabolomes of human urine samples collected before and after drinking coffee. To demonstrate that this method is reliable for data processing, five (13)C2-/(12)C2-dansyl labeled metabolite standards were analyzed by LC-MS. IsoMS was able to detect these metabolites correctly. In addition, in the analysis of a (13)C2-/(12)C2-dansyl labeled human urine, IsoMS detected 2044 peak pairs, and manual inspection of these peak pairs found 90 false peak pairs, representing a false positive rate of 4.4%. IsoMS for Windows running R is freely available for noncommercial use from www.mycompoundid.org/IsoMS.

  3. Changing activity in MS lesions

    International Nuclear Information System (INIS)

    Kermode, A.G.; Tofts, P.S.; Thompson, A.J.; Rudge, P.; MacManus, D.G.; Kendall, B.E.; Moseley, I.F.; Kingsley, D.P.E.; McDonald, W.I.

    1989-01-01

    Gd-DTPA enhanced T1 weighted MRI is a discriminating test for a defective blood-brain barrier, with MS lesions showing considerable variation in the pattern of enhancement. Since little is known of the changes in the blood-brain barrier in the active plaque over time, the natural history of blood-brain barrier disturbance in the MS lesion was examined to confirm earlier reports that Gd-DTPA enhancement is a consistent early event in new lesions of relapsing/remitting MS. This knowledge is essential for the use of MRI in monitoring treatment. (author). 9 refs

  4. Determination of rare earth elements in rice by INAA and ICP-MS

    International Nuclear Information System (INIS)

    Pham Thi Huynh, M.; Chu Pham Ngoc, S.; Carrot, F.; Revel, G.; Dang Vu, M.

    1997-01-01

    Irrigation of rice plants with a solution of rare earth elements increases both the production capacity and the resistance to disease. Assuming that the treated plants remain expendable, the different parts of plants, root stalk and grain, were analyzed by instrumental neutron activation analysis (INAA) and by mass spectrometry after plasma excitation (ICP-MS). About 40 elements were determined. The results showed that the contamination remained in the roots and was absent in rice grains. The analytical distribution of different elements in different parts of both treated and non-treated plants has given some information concerning the possible effect of the rare earth treatment. The performances of the two analytical methods have been compared. (author)

  5. Postmortem Kanda LC-MS MS ile Yasadışı Madde Taraması 62 Postmortem Adli Olguda Uygulanması

    Directory of Open Access Journals (Sweden)

    Serap Annette Akgür

    2007-04-01

    Full Text Available Biyolojik örneklerdeki yasadışı madde taraması adli olaylarda büyük bir öneme sahiptir. Kan veya plazma, madde derişim-leri ile bu maddelerin farmakolojik etkileri arasında iyi bir korelasyonun bulunması nedeniyle genellikle tercih edilen materyallerdir. Yasadışı madde analizinde, birçok laboratuar immunoassay yöntemleri ile tarama ve Gaz Kromatografi-Kütle Spektrometresi (GC-MS ile doğrulama şeklinde bir uygulama yapmaktadır. Bununla birlikte, sıvı kromatografi tekniklerinin gelişmesiyle birlikte Sıvı Kromatografisi-Kütle Spektrometresi (LC-MS ve tandem LC-MS (LC-MS/MS birleştirilmiş tekniklerinde özellikle polar ve ısıya dayanıksız olan maddelerin nitel ve nicel analiz amaçlı olarak kullanımı zamanla artmaktadır. Bu çalışmada, LC-ESI (Electrospray İonisation-MS/MS de morfin, (±-amfetamin, (+-metamfetamin, kokain, benzolekgonin, kokaetilen ve (--ll-nor-9-karboksi-t9-THC maddeleri taranmış ve tayin edilmiştir. Sonuç olarak, postmortem kanda uygulanabilecek, türevlendirme işlemine gerek duymayan, duyarlı ve seçimli olarak, çok düşük düzeylerdeki maddelerin doğru ve kesin olarak saptanmasını sağlayacak, LC-MS/MS yöntemi geliştirilmiş ve 62 postmortem adli olguya başarıyla uygulanmıştır. Anahtar kelimeler: Yasadışı madde, tarama, LC/MS/MS, postmortem kan

  6. RAId_aPS: MS/MS analysis with multiple scoring functions and spectrum-specific statistics.

    Science.gov (United States)

    Alves, Gelio; Ogurtsov, Aleksey Y; Yu, Yi-Kuo

    2010-11-16

    Statistically meaningful comparison/combination of peptide identification results from various search methods is impeded by the lack of a universal statistical standard. Providing an E-value calibration protocol, we demonstrated earlier the feasibility of translating either the score or heuristic E-value reported by any method into the textbook-defined E-value, which may serve as the universal statistical standard. This protocol, although robust, may lose spectrum-specific statistics and might require a new calibration when changes in experimental setup occur. To mitigate these issues, we developed a new MS/MS search tool, RAId_aPS, that is able to provide spectrum-specific-values for additive scoring functions. Given a selection of scoring functions out of RAId score, K-score, Hyperscore and XCorr, RAId_aPS generates the corresponding score histograms of all possible peptides using dynamic programming. Using these score histograms to assign E-values enables a calibration-free protocol for accurate significance assignment for each scoring function. RAId_aPS features four different modes: (i) compute the total number of possible peptides for a given molecular mass range, (ii) generate the score histogram given a MS/MS spectrum and a scoring function, (iii) reassign E-values for a list of candidate peptides given a MS/MS spectrum and the scoring functions chosen, and (iv) perform database searches using selected scoring functions. In modes (iii) and (iv), RAId_aPS is also capable of combining results from different scoring functions using spectrum-specific statistics. The web link is http://www.ncbi.nlm.nih.gov/CBBresearch/Yu/raid_aps/index.html. Relevant binaries for Linux, Windows, and Mac OS X are available from the same page.

  7. UFLC-ESI-MS/MS analysis of multiple mycotoxins in medicinal and edible Areca catechu.

    Science.gov (United States)

    Liu, Hongmei; Luo, Jiaoyang; Kong, Weijun; Liu, Qiutao; Hu, Yichen; Yang, Meihua

    2016-05-01

    A robust, sensitive and reliable ultra fast liquid chromatography combined with electrospray ionization tandem mass spectrometry (UFLC-ESI-MS/MS) was optimized and validated for simultaneous identification and quantification of eleven mycotoxins in medicinal and edible Areca catechu, based on one-step extraction without any further clean-up. Separation and quantification were performed in both positive and negative modes under multiple reaction monitoring (MRM) in a single run with zearalanone (ZAN) as internal standard. The chromatographic conditions and MS/MS parameters were carefully optimized. Matrix-matched calibration was recommended to reduce matrix effects and improve accuracy, showing good linearity within wide concentration ranges. Limits of quantification (LOQ) were lower than 50 μg kg(-1), while limits of detection (LOD) were in the range of 0.1-20 μg kg(-1). The accuracy of the developed method was validated for recoveries, ranging from 85% to 115% with relative standard deviation (RSD) ≤14.87% at low level, from 75% to 119% with RSD ≤ 14.43% at medium level and from 61% to 120% with RSD ≤ 13.18% at high level, respectively. Finally, the developed multi-mycotoxin method was applied for screening of these mycotoxins in 24 commercial samples. Only aflatoxin B2 and zearalenone were found in 2 samples. This is the first report on the application of UFLC-ESI(+/-)-MS/MS for multi-class mycotoxins in A. catechu. The developed method with many advantages of simple pretreatment, rapid determination and high sensitivity is a proposed candidate for large-scale detection and quantification of multiple mycotoxins in other complex matrixes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Single particle analysis of TiO2 in candy products using triple quadrupole ICP-MS.

    Science.gov (United States)

    Candás-Zapico, S; Kutscher, D J; Montes-Bayón, M; Bettmer, J

    2018-04-01

    Titanium dioxide (TiO 2 ) belongs to the materials that have gained great importance in many applications. In its particulate form (micro- or nanoparticles), it has entered a huge number of consumer products and food-grade TiO 2 , better known as E171 within the European Union, represents an important food additive. Thus, there is an increasing need for analytical methods able to detect and quantify such particles. In this regard, inductively coupled-mass spectrometry (ICP-MS), in particular single particle ICP-MS (spICP-MS), has gained importance due to its simplicity and ease of use. Nevertheless, the number of applications for Ti nanoparticles is rather limited. In this study, we have applied the spICP-MS strategy by comparing different measuring modes available in triple quadrupole ICP-MS. First, single quadrupole mode using the collision/reaction cell system was selected for monitoring the isotope 47 Ti. Different cell gases like He, O 2 and NH 3 were tested under optimised conditions for its applicability in spICP-MS of standard suspensions of TiO 2 . The determined analytical figures of merit were compared to those obtained by triple quadrupole mode using the 47 Ti or 48 Ti reaction products using O 2 and NH 3 as reaction gases. This comparison demonstrated that the triple quadrupole mode (TQ mode) was superior in terms of sensitivity due to the more efficient removal of spectral interferences. Particle size detection limits down to 26nm were obtained using the best instrumental conditions for TiO 2 particles at a dwell time of 10ms. Finally, the different measuring modes were applied to the analysis of chewing gum samples after a simple extraction procedure using an ultrasonic bath. The obtained results showed a good agreement for the detected particle size range using the different TQ modes. The size range of TiO 2 particles was determined to be between approximately 30 and 200nm, whereas roughly 40% of the particles were smaller than 100nm. For the

  9. Risk Assessment Stability: A Revalidation Study of the Arizona Risk/Needs Assessment Instrument

    Science.gov (United States)

    Schwalbe, Craig S.

    2009-01-01

    The actuarial method is the gold standard for risk assessment in child welfare, juvenile justice, and criminal justice. It produces risk classifications that are highly predictive and that may be robust to sampling error. This article reports a revalidation study of the Arizona Risk/Needs Assessment instrument, an actuarial instrument for juvenile…

  10. Non-enzymolytic adenosine barcode-mediated dual signal amplification strategy for ultrasensitive protein detection using LC-MS/MS.

    Science.gov (United States)

    Yang, Wen; Li, Tengfei; Shu, Chang; Ji, Shunli; Wang, Lei; Wang, Yan; Li, Duo; Mtalimanja, Michael; Sun, Luning; Ding, Li

    2018-05-10

    A method is described for the determination of proteins with LC-MS/MS enabled by a small molecule (adenosine) barcode and based on a double-recognition sandwich structure. The coagulation protein thrombin was chosen as the model analyte. Magnetic nanoparticles were functionalized with aptamer29 (MNP/apt29) and used to capture thrombin from the samples. MNP/apt29 forms a sandwich with functionalized gold nanoparticles modified with (a) aptamer15 acting as thrombin-recognizing element and (b) a large number of adenosine as mass barcodes. The sandwich formed (MNP/apt29-thrombin-apt15/AuNP/adenosine) can ben magnetically separated from the sample. Mass barcodes are subsequently released from the sandwiched structure for further analysis by adding 11-mercaptoundecanoic acid. Adenosine is then detected by LC-MS/MS as it reflects the level of thrombin with impressively amplified signal. Numerous adenosines introduced into the sandwich proportional to the target concentration further amplify the signal. Under optimized conditions, the response is linearly proportional to the thrombin concentration in the range of 0.02 nM to 10 nM, with a detection limit of 9 fM. The application of this method to the determination of thrombin in spiked plasma samples gave recoveries that ranged from 92.3% to 104.7%. Graphical abstract Schematic representation of a method for the determination of thrombin with LC-MS/MS. The method is based on a double-recognition sandwiched structure. With LC-MS/MS, mass barcodes (adenosine) are detected to quantify thrombin, which amplifies the detection signal impressively.

  11. Neural Network Prediction of Disruptions Caused by Locked Modes on J-TEXT Tokamak

    International Nuclear Information System (INIS)

    Ding Yonghua; Jin Xuesong; Chen Zhenzhen; Zhuang Ge

    2013-01-01

    Prediction of disruptions caused by locked modes using the Back-Propagation (BP) neural network is completed on J-TEXT tokamak. The network, which is based on the BP neural network, uses Mirnov coils and locked mode coils signals as input data, and outputs a signal including information of prediction of locked mode. The rate of successful prediction of locked modes is more than 90%. For intrinsic locked mode disruptions, the network can give a prewarning signal about 1 ms ahead of the locking-time. For the disruption caused by resonant magnetic perturbation (RMPs) locked modes, the network can give a prewarning signal about 10 ms ahead of the locking-time

  12. Identification of the Chemical Constituents in Simiao Wan and Rat Plasma after Oral Administration by GC-MS and LC-MS

    Directory of Open Access Journals (Sweden)

    Yunshuang Fan

    2017-01-01

    Full Text Available Simiao Wan (SMW, an important multiherbal formula used in traditional Chinese medicine, is extensively used to treat rheumatoid arthritis. However, the knowledge of the bioactive components of SMW remains unclear. Thus, gas chromatography–mass spectrometry (GC-MS and liquid chromatography–mass spectrometry (LC-MS were used to analyze the chemical constituents of volatile and nonvolatile extracts of SMW, as well as its absorbed components in rat plasma after oral SMW administration. Identification of several compounds was enabled by comparison of retention times, MS spectra, and MS/MS spectral data with the standard substance and reference materials reported in the literature. In the volatile extracts, GC-MS identified 26 compounds in vitro, three of which observed in blood by GC-MS. In the nonvolatile extracts, LC-MS identified 49 compounds in SMW; 18 compounds containing 7 prototype compounds, 5 metabolites, and 6 unknown compounds were absorbed by blood. The proposed GC-MS and LC-MS method was appropriate not only for the rapid screening and identification of multiple components of an SMW extract but also for screening its bioactive constituents in vivo. The proposed method could be a promising tool for the quality control of other Chinese herbal medicines.

  13. Linear Ion Traps in Space: The Mars Organic Molecule Analyzer (MOMA) Instrument and Beyond

    Science.gov (United States)

    Arevalo, Ricardo; Brinckerhoff, William; Mahaffy, Paul; van Amerom, Friso; Danell, Ryan; Pinnick, Veronica; Li, Xiang; Hovmand, Lars; Getty, Stephanie; Grubisic, Andrej; Goesmann, Fred; Cottin, Hervé

    2015-11-01

    Historically, quadrupole mass spectrometer (QMS) instruments have been used to explore a wide survey of planetary targets in our solar system, from Venus (Pioneer Venus) to Saturn (Cassini-Huygens). However, linear ion trap (LIT) mass spectrometers have found a niche as smaller, versatile alternatives to traditional quadrupole analyzers.The core astrobiological experiment of ESA’s ExoMars Program is the Mars Organic Molecule Analyzer (MOMA) onboard the ExoMars 2018 rover. The MOMA instrument is centered on a linear (or 2-D) ion trap mass spectrometer. As opposed to 3-D traps, LIT-based instruments accommodate two symmetrical ion injection pathways, enabling two complementary ion sources to be used. In the case of MOMA, these two analytical approaches are laser desorption mass spectrometry (LDMS) at Mars ambient pressures, and traditional gas chromatography mass spectrometry (GCMS). The LIT analyzer employed by MOMA also offers: higher ion capacity compared to a 3-D trap of the same volume; redundant detection subassemblies for extended lifetime; and, a link to heritage QMS designs and assembly logistics. The MOMA engineering test unit (ETU) has demonstrated the detection of organics in the presence of wt.%-levels of perchlorate, effective ion enhancement via stored waveform inverse Fourier transform (SWIFT), and derivation of structural information through tandem mass spectrometry (MS/MS).A more progressive linear ion trap mass spectrometer (LITMS), funded by the NASA ROSES MatISSE Program, is being developed at NASA GSFC and promises to augment the capabilities of the MOMA instrument by way of: an expanded mass range (i.e., 20 - 2000 Da); detection of both positive and negative ions; spatially resolved (<1 mm) characterization of individual rock core layers; and, evolved gas analysis and GCMS with pyrolysis up to 1300° C (enabling breakdown of refractory phases). The Advanced Resolution Organic Molecule Analyzer (AROMA) instrument, being developed through NASA

  14. Determination of chlormequat in pig serum and sow milk by LC-MS/MS.

    Science.gov (United States)

    Poulsen, M E; Christensen, H B; Sørensen, M T; Leffers, H; Andersen, J H

    2007-11-01

    Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC-MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80-110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g-4.0 ng/g.

  15. Determination of selected bisphenols, parabens and estrogens in human plasma using LC-MS/MS

    Czech Academy of Sciences Publication Activity Database

    Kolatorova Sosvorova, L.; Chlupacova, T.; Vitku, J.; Vlk, Martin; Heráček, J.; Stárka, L.; Šaman, David; Šimková, M.; Hampl, R.

    2017-01-01

    Roč. 174, NOV 1 (2017), s. 21-28 ISSN 0039-9140 Institutional support: RVO:61389030 ; RVO:61388963 Keywords : Alternative bisphenol * Bisphenol A * Bisphenol F * Endocrine disruptor * lc-ms/ms * Paraben Subject RIV: CC - Organic Chemistry OBOR OECD: Analytical chemistry; Organic chemistry (UOCHB-X) Impact factor: 4.162, year: 2016

  16. Profiling the Oxylipin and Endocannabinoid Metabolome by UPLC-ESI-MS/MS in Human Plasma to Monitor Postprandial Inflammation.

    Science.gov (United States)

    Gouveia-Figueira, Sandra; Späth, Jana; Zivkovic, Angela M; Nording, Malin L

    2015-01-01

    Bioactive lipids, including oxylipins, endocannabinoids, and related compounds may function as specific biochemical markers of certain aspects of inflammation. However, the postprandial responsiveness of these compounds is largely unknown; therefore, changes in the circulating oxylipin and endocannabinoid metabolome in response to a challenge meal were investigated at six occasions in a subject who freely modified her usual diet. The dietary change, and especially the challenge meal itself, represented a modification of precursor fatty acid status, with expectedly subtle effects on bioactive lipid levels. To detect even the slightest alteration, highly sensitive ultra-performance liquid chromatography (UPLC) coupled to electrospray ionization (ESI) tandem mass spectrometry (MS/MS) methods for bioactive lipid profiling was employed. A previously validated UPLC-ESI-MS/MS method for profiling the endocannabinoid metabolome was used, while validation of an UPLC-ESI-MS/MS method for oxylipin analysis was performed with acceptable outcomes for a majority of the parameters according to the US Food and Drug Administration guidelines for linearity (0.9938 metabolome, caused by changes in diet and ii) responsiveness to a challenge meal for a subset of the oxylipin and endocannabinoid metabolome. To summarize, we have shown proof-of-concept of our UPLC-ESI-MS/MS bioactive lipid protocols for the purpose of monitoring subtle shifts, and thereby useful to address lipid-mediated postprandial inflammation.

  17. Direct, rapid quantitative analyses of BVOCs using SIFT-MS and PTR-MS obviating sample collection

    Czech Academy of Sciences Publication Activity Database

    Smith, D.; Španěl, Patrik

    2011-01-01

    Roč. 30, č. 7 (2011), s. 945-959 ISSN 0165-9936 Institutional research plan: CEZ:AV0Z40400503 Keywords : SIFT-MS * PTR-MS * Absolute quantification Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 6.273, year: 2011

  18. Optimization and Comparison of ESI and APCI LC-MS/MS Methods: A Case Study of Irgarol 1051, Diuron, and their Degradation Products in Environmental Samples

    Science.gov (United States)

    Maragou, Niki C.; Thomaidis, Nikolaos S.; Koupparis, Michael A.

    2011-10-01

    A systematic and detailed optimization strategy for the development of atmospheric pressure ionization (API) LC-MS/MS methods for the determination of Irgarol 1051, Diuron, and their degradation products (M1, DCPMU, DCPU, and DCA) in water, sediment, and mussel is described. Experimental design was applied for the optimization of the ion sources parameters. Comparison of ESI and APCI was performed in positive- and negative-ion mode, and the effect of the mobile phase on ionization was studied for both techniques. Special attention was drawn to the ionization of DCA, which presents particular difficulty in API techniques. Satisfactory ionization of this small molecule is achieved only with ESI positive-ion mode using acetonitrile in the mobile phase; the instrumental detection limit is 0.11 ng/mL. Signal suppression was qualitatively estimated by using purified and non-purified samples. The sample preparation for sediments and mussels is direct and simple, comprising only solvent extraction. Mean recoveries ranged from 71% to 110%, and the corresponding (%) RSDs ranged between 4.1 and 14%. The method limits of detection ranged between 0.6 and 3.5 ng/g for sediment and mussel and from 1.3 to 1.8 ng/L for sea water. The method was applied to sea water, marine sediment, and mussels, which were obtained from marinas in Attiki, Greece. Ion ratio confirmation was used for the identification of the compounds.

  19. Novel functional polymorphism in IGF-1 gene associated with multiple sclerosis: A new insight to MS.

    Science.gov (United States)

    Shahbazi, Majid; Abdolmohammadi, Reza; Ebadi, Hamid; Farazmandfar, Touraj

    2017-04-01

    Interactions between several genes and environment may play a role in susceptibility to multiple sclerosis (MS). The IGF-1 plays a key role in proliferation, maintenance and survival of nerve cells. Therefore, we hypothesized that IGF-1 may be a target for prediction and control MS. We aimed to analysis IGF-1 gene promoter sequence, to investigate the effect of the single nucleotide variants on IGF-1 expression and its association with MS. We enrolled 339 MS patients and 431 healthy controls. A specific region in IGF-1 gene promoter was investigated by SSCP analysis. All samples were genotyped by SSP-PCR. In-vitro and in-vivo IGF-1 production was measured by ELISA assay. IGF-1 expression in PBMCs was measured using real-time PCR. We identified a T to C single nucleotide substitution at position -1089 and a C to T at position -383 from transcription start site in the IGF-1 gene promoter. There was a significant association between MS and genotypes IGF-1(-383) C/T (p=0.001) and IGF-1(-383) C/C (pMS (p=0.001). In-vitro and in-vivo IGF-1 level showed that IGF-1 production in samples with genotype IGF-1(-383) C/C significantly was less than T/T (p=0.004) but not T/C (p=0.220). According to IGF-1 roles in CNS and our results, this study suggests that low IGF-1 level may be associated with susceptibility to MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Factors Associated with Neurologists' Provision of MS Patient Care

    Science.gov (United States)

    Halpern, Michael T.; Teixeira-Poit, Stephanie M.; Kane, Heather; Frost, Corey; Keating, Michael; Olmsted, Murrey

    2014-01-01

    Neurologists are central to providing quality care for individuals with MS. However, neurologist shortages may restrict access to care for MS patients. To examine factors influencing neurologists' provision of MS care, we surveyed 1,700 US neurologists to assess demographic/practice characteristics, training, and attitudes toward MS care. The study population consisted of 573 respondents: 87 (15.2%) MS subspecialists and 486 (84.8%) “other neurologists,” including subspecialists in other neurology areas (i.e., non-MS) and general neurologists. MS subspecialists indicating they “enjoy interacting with MS patients” had a significantly greater rate of MS patients seen per week. In separate analyses of the “other neurologists” group, the rate of MS patients seen was lower among neurologists in university-based groups or those practicing in major cities; female neurologists; and neurologists who indicated lack of sufficient knowledge regarding MS patient care. Rates of MS patients seen were significantly greater for other neurologists who agreed that MS care involved “ability to improve patient outcomes and quality of life”; “dynamic area with evolving treatment options”; and “enjoy interacting with MS patients.” Understanding factors influencing MS patient care by neurologists and developing policies for appropriate access to care is critical for optimal outcomes among this population. PMID:24949203

  1. Factors Associated with Neurologists’ Provision of MS Patient Care

    Directory of Open Access Journals (Sweden)

    Michael T. Halpern

    2014-01-01

    Full Text Available Neurologists are central to providing quality care for individuals with MS. However, neurologist shortages may restrict access to care for MS patients. To examine factors influencing neurologists’ provision of MS care, we surveyed 1,700 US neurologists to assess demographic/practice characteristics, training, and attitudes toward MS care. The study population consisted of 573 respondents: 87 (15.2% MS subspecialists and 486 (84.8% “other neurologists,” including subspecialists in other neurology areas (i.e., non-MS and general neurologists. MS subspecialists indicating they “enjoy interacting with MS patients” had a significantly greater rate of MS patients seen per week. In separate analyses of the “other neurologists” group, the rate of MS patients seen was lower among neurologists in university-based groups or those practicing in major cities; female neurologists; and neurologists who indicated lack of sufficient knowledge regarding MS patient care. Rates of MS patients seen were significantly greater for other neurologists who agreed that MS care involved “ability to improve patient outcomes and quality of life”; “dynamic area with evolving treatment options”; and “enjoy interacting with MS patients.” Understanding factors influencing MS patient care by neurologists and developing policies for appropriate access to care is critical for optimal outcomes among this population.

  2. What Is in Your Wallet? Quantitation of Drugs of Abuse on Paper Currency with a Rapid LC-MS/MS Method

    Science.gov (United States)

    Parker, Patrick D.; Beers, Brandon; Vergne, Matthew J.

    2017-01-01

    Laboratory experiments were developed to introduce students to the quantitation of drugs of abuse by high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Undergraduate students were introduced to internal standard quantitation and the LC-MS/MS method optimization for cocaine. Cocaine extracted from paper currency was…

  3. Comparison of piracetam measured with HPLC-DAD, HPLC-ESI-MS, DIP-APCI-MS, and a newly developed and optimized DIP-ESI-MS.

    Science.gov (United States)

    Lenzen, Claudia; Winterfeld, Gottfried A; Schmitz, Oliver J

    2016-06-01

    The direct inlet probe-electrospray ionization (DIP-ESI) presented here was based on the direct inlet probe-atmospheric pressure chemical ionization (DIP-APCI) developed by our group. It was coupled to an ion trap mass spectrometer (MS) for the detection of more polar compounds such as degradation products from pharmaceuticals. First, the position of the ESI tip, the gas and solvent flow rates, as well as the gas temperature were optimized with the help of the statistic program Minitab® 17 and a caffeine standard. The ability to perform quantitative analyses was also tested by using different concentrations of caffeine and camphor. Calibration curves with a quadratic calibration regression of R (2) = 0.9997 and 0.9998 for caffeine and camphor, respectively, were obtained. The limit of detection of 2.5 and 1.7 ng per injection for caffeine and camphor were determined, respectively. Furthermore, a solution of piracetam was used to compare established analytical methods for this drug and its impurities such as HPLC-diode array detector (DAD) and HPLC-ESI-MS with the DIP-APCI and the developed DIP-ESI. With HPLC-DAD and 10 μg piracetam on column, no impurity could be detected. With HPLC-ESI-MS, two impurities (A and B) were identified with only 4.6 μg piracetam on column, while with DIP-ESI, an amount of 1.6 μg piracetam was sufficient. In the case of the DIP-ESI measurements, all detected impurities could be identified by MS/MS studies. Graphical Abstract Scheme of the DIP-ESI principle.

  4. Combined visual and motor evoked potentials predict multiple sclerosis disability after 20 years.

    Science.gov (United States)

    Schlaeger, Regina; Schindler, Christian; Grize, Leticia; Dellas, Sophie; Radue, Ernst W; Kappos, Ludwig; Fuhr, Peter

    2014-09-01

    The development of predictors of multiple sclerosis (MS) disability is difficult due to the complex interplay of pathophysiological and adaptive processes. The purpose of this study was to investigate whether combined evoked potential (EP)-measures allow prediction of MS disability after 20 years. We examined 28 patients with clinically definite MS according to Poser's criteria with Expanded Disability Status Scale (EDSS) scores, combined visual and motor EPs at entry (T0), 6 (T1), 12 (T2) and 24 (T3) months, and a cranial magnetic resonance imaging (MRI) scan at T0 and T2. EDSS testing was repeated at year 14 (T4) and year 20 (T5). Spearman rank correlation was used. We performed a multivariable regression analysis to examine predictive relationships of the sum of z-transformed EP latencies (s-EPT0) and other baseline variables with EDSST5. We found that s-EPT0 correlated with EDSST5 (rho=0.72, pdisability in MS. © The Author(s) 2014.

  5. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  6. Comprehensive comparison of in silico MS/MS fragmentation tools of the CASMI contest: database boosting is needed to achieve 93% accuracy.

    Science.gov (United States)

    Blaženović, Ivana; Kind, Tobias; Torbašinović, Hrvoje; Obrenović, Slobodan; Mehta, Sajjan S; Tsugawa, Hiroshi; Wermuth, Tobias; Schauer, Nicolas; Jahn, Martina; Biedendieck, Rebekka; Jahn, Dieter; Fiehn, Oliver

    2017-05-25

    In mass spectrometry-based untargeted metabolomics, rarely more than 30% of the compounds are identified. Without the true identity of these molecules it is impossible to draw conclusions about the biological mechanisms, pathway relationships and provenance of compounds. The only way at present to address this discrepancy is to use in silico fragmentation software to identify unknown compounds by comparing and ranking theoretical MS/MS fragmentations from target structures to experimental tandem mass spectra (MS/MS). We compared the performance of four publicly available in silico fragmentation algorithms (MetFragCL, CFM-ID, MAGMa+ and MS-FINDER) that participated in the 2016 CASMI challenge. We found that optimizing the use of metadata, weighting factors and the manner of combining different tools eventually defined the ultimate outcomes of each method. We comprehensively analysed how outcomes of different tools could be combined and reached a final success rate of 93% for the training data, and 87% for the challenge data, using a combination of MAGMa+, CFM-ID and compound importance information along with MS/MS matching. Matching MS/MS spectra against the MS/MS libraries without using any in silico tool yielded 60% correct hits, showing that the use of in silico methods is still important.

  7. Thermal and Alignment Analysis of the Instrument-Level ATLAS Thermal Vacuum Test

    Science.gov (United States)

    Bradshaw, Heather

    2012-01-01

    This paper describes the thermal analysis and test design performed in preparation for the ATLAS thermal vacuum test. NASA's Advanced Topographic Laser Altimeter System (ATLAS) will be flown as the sole instrument aboard the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). It will be used to take measurements of topography and ice thickness for Arctic and Antarctic regions, providing crucial data used to predict future changes in worldwide sea levels. Due to the precise measurements ATLAS is taking, the laser altimeter has very tight pointing requirements. Therefore, the instrument is very sensitive to temperature-induced thermal distortions. For this reason, it is necessary to perform a Structural, Thermal, Optical Performance (STOP) analysis not only for flight, but also to ensure performance requirements can be operationally met during instrument-level thermal vacuum testing. This paper describes the thermal model created for the chamber setup, which was used to generate inputs for the environmental STOP analysis. This paper also presents the results of the STOP analysis, which indicate that the test predictions adequately replicate the thermal distortions predicted for flight. This is a new application of an existing process, as STOP analyses are generally performed to predict flight behavior only. Another novel aspect of this test is that it presents the opportunity to verify pointing results of a STOP model, which is not generally done. It is possible in this case, however, because the actual pointing will be measured using flight hardware during thermal vacuum testing and can be compared to STOP predictions.

  8. Brain reserve and cognitive reserve protect against cognitive decline over 4.5 years in MS.

    Science.gov (United States)

    Sumowski, James F; Rocca, Maria A; Leavitt, Victoria M; Dackovic, Jelena; Mesaros, Sarlota; Drulovic, Jelena; DeLuca, John; Filippi, Massimo

    2014-05-20

    Based on the theories of brain reserve and cognitive reserve, we investigated whether larger maximal lifetime brain growth (MLBG) and/or greater lifetime intellectual enrichment protect against cognitive decline over time. Forty patients with multiple sclerosis (MS) underwent baseline and 4.5-year follow-up evaluations of cognitive efficiency (Symbol Digit Modalities Test, Paced Auditory Serial Addition Task) and memory (Selective Reminding Test, Spatial Recall Test). Baseline and follow-up MRIs quantified disease progression: percentage brain volume change (cerebral atrophy), percentage change in T2 lesion volume. MLBG (brain reserve) was estimated with intracranial volume; intellectual enrichment (cognitive reserve) was estimated with vocabulary. We performed repeated-measures analyses of covariance to investigate whether larger MLBG and/or greater intellectual enrichment moderate/attenuate cognitive decline over time, controlling for disease progression. Patients with MS declined in cognitive efficiency and memory (p improve prediction of future cognitive decline in patients with MS. © 2014 American Academy of Neurology.

  9. Determination of post-culture processing with carbohydrates by MALDI-MS and TMS derivatization GC-MS.

    Science.gov (United States)

    Wunschel, David S; Wahl, Karen L; Melville, Angela M; Sorensen, Christina M; Colburn, Heather A; Valentine, Nancy B; Stamper, Casey L

    2011-10-15

    Biological materials generally require stabilization to retain activity or viability in a dry form. A number of industrial products, such as vaccines, probiotics and biopesticides have been produced as dry preparations. The same methods and materials used for stabilizing commercial microbial products may be applicable to preserving biothreat pathogens in a dry form. This is a likely step that may be encountered when looking at samples from terrorism attempts since only spores, such as those from Bacillus anthracis, are inherently stable when dried. The stabilizers for microbial preparations generally include one or more small carbohydrates. Different formulations have been reported for different industrial products and are often determined empirically. However sugar alcohols (mannitol and sorbitol) and disaccharides (lactose, sucrose and trehalose) are the common constituents of these formulations. We have developed an analytical method for sample preparation and detection of these simple carbohydrates using two complementary analytical tools, MALDI-MS and GC-MS. The native carbohydrates and other constituents of the formulation are detected by MALDI-MS as a screening tool. A longer and more detailed analysis is then used to specifically identify the carbohydrates by derivatization and GC-MS detection. Both techniques were tested against ten different types of stabilization recipes with Yersinia pestis cell mass cultured on different media types used as the biological component. A number of additional components were included in these formulations including proteins and peptides from serum or milk, polymers (e.g. poly vinyl pyrrolidone - PVP) and detergents (e.g. Tween). The combined method was characterized to determine several figures of merit. The accuracy of the method was 98% for MALDI-MS and 100% for GC-MS. The repeatability for detection of carbohydrates by MALDI-MS was determined to be 96%. The repeatability of compound identification by GC-MS was

  10. Predicting violence and recidivism in a large sample of males on probation or parole.

    Science.gov (United States)

    Prell, Lettie; Vitacco, Michael J; Zavodny, Denis

    This study evaluated the utility of items and scales from the Iowa Violence and Victimization Instrument in a sample of 1961 males from the state of Iowa who were on probation or released from prison to parole supervision. This is the first study to examine the potential of the Iowa Violence and Victimization Instrument to predict criminal offenses. The males were followed for 30months immediately following their admission to probation or parole. AUC analyses indicated fair to good predictive power for the Iowa Violence and Victimization Instrument for charges of violence and victimization, but chance predictive power for drug offenses. Notably, both scales of the instrument performed equally well at the 30-month follow-up. Items on the Iowa Violence and Victimization Instrument not only predicted violence, but are straightforward to score. Violence management strategies are discussed as they relate to the current findings, including the potential to expand the measure to other jurisdictions and populations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Phenolic Profiling of Duchesnea indica Combining Macroporous Resin Chromatography (MRC with HPLC-ESI-MS/MS and ESI-IT-MS

    Directory of Open Access Journals (Sweden)

    Mingzhi Zhu

    2015-12-01

    Full Text Available Duchesnea indica (D. indica is an important traditional Chinese medicine, and has long been clinically used to treat cancer in Asian countries. It has been described previously as a rich source of phenolic compounds with a broad array of diversified structures, which are the major active ingredients. However, an accurate and complete phenolic profiling has not been determined yet. In the present work, the total phenolic compounds in crude extracts from D. indica were enriched and fractionated over a macroporous resin column, then identified by HPLC-ESI-MS/MS and ESI-IT-MS (ion trap MS. A total of 27 phenolic compounds were identified in D. indica, of which 21 compounds were identified for the first time. These 27 phenolic compounds encompassing four phenolic groups, including ellagitannins, ellagic acid and ellagic acid glycosides, hydroxybenzoic acid and hydroxycinnamic acid derivatives, and flavonols, were then successfully quantified using peak areas against those of the corresponding standards with good linearity (R2 > 0.998 in the range of the tested concentrations. As a result, the contents of individual phenolic compounds varied from 6.69 mg per 100 g dry weight (DW for ellagic acid to 71.36 mg per 100 g DW for brevifolin carboxylate. Not only did this study provide the first phenolic profiling of D. indica, but both the qualitative identification and the subsequent quantitative analysis of 27 phenolic compounds from D. indica should provide a good basis for future exploration of this valuable medicinal plant.

  12. Rapid Determination of Isomeric Benzoylpaeoniflorin and Benzoylalbiflorin in Rat Plasma by LC-MS/MS Method

    Directory of Open Access Journals (Sweden)

    Chuanqi Zhou

    2017-01-01

    Full Text Available Benzoylpaeoniflorin (BP is a potential therapeutic agent against oxidative stress related Alzheimer’s disease. In this study, a more rapid, selective, and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS method was developed to determine BP in rat plasma distinguishing with a monoterpene isomer, benzoylalbiflorin (BA. The method showed a linear response from 1 to 1000 ng/mL (r>0.9950. The precision of the interday and intraday ranged from 2.03 to 12.48% and the accuracy values ranged from −8.00 to 10.33%. Each running of the method could be finished in 4 minutes. The LC-MS/MS method was validated for specificity, linearity, precision, accuracy, recovery, and stability and was found to be acceptable for bioanalytical application. Finally, this fully validated method was successfully applied to a pharmacokinetic study in rats following oral administration.

  13. Complex mixture analysis of peptides using LC/LC-MS/MS and data-dependent protein identification

    International Nuclear Information System (INIS)

    Wasinger, V.; Corthals, G.

    2001-01-01

    The comprehensive identification of proteins within complex solutions by mass-spectrometry largely depends on the sensitivity, resolving power and sampling efficiency of the technology. An integrated orthogonal approach using Strong Cation Exchange-Reverse Phase-MS/MS (SCX-RP-MS/MS) was used to evaluate the data-dependent Collision Induced Dissociation (CID) of yeast peptides. Reverse phase gradient times of 4, 10. 30, 90, and 180 minutes allowed the identification of hundreds of proteins in a nearly automated fashion from nuclear, membrane, and cytosolic distributions. Many proteins from typically difficult to resolve regions of two-dimensional gels, such as >100kDa, > pI 9.0 and Codon Adaptation Index < 0.2, were also identified using this multi-dimensional separation technology. Few low mass proteins (<10kDa) were identified. The impact of scan-range and duty-cycle on CID of peptides will be discussed

  14. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  15. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  16. Evaluation of a Method for Nitrotyrosine Site Identification and Relative Quantitation Using a Stable Isotope-Labeled Nitrated Spike-In Standard and High Resolution Fourier Transform MS and MS/MS Analysis

    Directory of Open Access Journals (Sweden)

    Kent W. Seeley

    2014-04-01

    Full Text Available The overproduction of reactive oxygen and nitrogen species (ROS and RNS can have deleterious effects in the cell, including structural and possible activity-altering modifications to proteins. Peroxynitrite is one such RNS that can result in a specific protein modification, nitration of tyrosine residues to form nitrotyrosine, and to date, the identification of nitrotyrosine sites in proteins continues to be a major analytical challenge. We have developed a method by which 15N-labeled nitrotyrosine groups are generated on peptide or protein standards using stable isotope-labeled peroxynitrite (O15NOO−, and the resulting standard is mixed with representative samples in which nitrotyrosine formation is to be measured by mass spectrometry (MS. Nitropeptide MS/MS spectra are filtered using high mass accuracy Fourier transform MS (FTMS detection of the nitrotyrosine immonium ion. Given that the nitropeptide pair is co-isolated for MS/MS fragmentation, the nitrotyrosine immonium ions (at m/z = 181 or 182 can be used for relative quantitation with negligible isotopic interference at a mass resolution of greater than 50,000 (FWHM, full width at half-maximum. Furthermore, the standard potentially allows for the increased signal of nitrotyrosine-containing peptides, thus facilitating selection for MS/MS in a data-dependent mode of acquisition. We have evaluated the methodology in terms of nitrotyrosine site identification and relative quantitation using nitrated peptide and protein standards.

  17. High-precision isotopic characterization of USGS reference materials by TIMS and MC-ICP-MS

    Science.gov (United States)

    Weis, Dominique; Kieffer, Bruno; Maerschalk, Claude; Barling, Jane; de Jong, Jeroen; Williams, Gwen A.; Hanano, Diane; Pretorius, Wilma; Mattielli, Nadine; Scoates, James S.; Goolaerts, Arnaud; Friedman, Richard M.; Mahoney, J. Brian

    2006-08-01

    The Pacific Centre for Isotopic and Geochemical Research (PCIGR) at the University of British Columbia has undertaken a systematic analysis of the isotopic (Sr, Nd, and Pb) compositions and concentrations of a broad compositional range of U.S. Geological Survey (USGS) reference materials, including basalt (BCR-1, 2; BHVO-1, 2), andesite (AGV-1, 2), rhyolite (RGM-1, 2), syenite (STM-1, 2), granodiorite (GSP-2), and granite (G-2, 3). USGS rock reference materials are geochemically well characterized, but there is neither a systematic methodology nor a database for radiogenic isotopic compositions, even for the widely used BCR-1. This investigation represents the first comprehensive, systematic analysis of the isotopic composition and concentration of USGS reference materials and provides an important database for the isotopic community. In addition, the range of equipment at the PCIGR, including a Nu Instruments Plasma MC-ICP-MS, a Thermo Finnigan Triton TIMS, and a Thermo Finnigan Element2 HR-ICP-MS, permits an assessment and comparison of the precision and accuracy of isotopic analyses determined by both the TIMS and MC-ICP-MS methods (e.g., Nd isotopic compositions). For each of the reference materials, 5 to 10 complete replicate analyses provide coherent isotopic results, all with external precision below 30 ppm (2 SD) for Sr and Nd isotopic compositions (27 and 24 ppm for TIMS and MC-ICP-MS, respectively). Our results also show that the first- and second-generation USGS reference materials have homogeneous Sr and Nd isotopic compositions. Nd isotopic compositions by MC-ICP-MS and TIMS agree to within 15 ppm for all reference materials. Interlaboratory MC-ICP-MS comparisons show excellent agreement for Pb isotopic compositions; however, the reproducibility is not as good as for Sr and Nd. A careful, sequential leaching experiment of three first- and second-generation reference materials (BCR, BHVO, AGV) indicates that the heterogeneity in Pb isotopic compositions

  18. Development and deployment of a compact PTR-ToF-MS for Suborbital Research on the Earth's Atmospheric Composition

    Science.gov (United States)

    Müller, Markus; Mikoviny, Tomas; Haidacher, Stefan; Hanel, Gernot; Hartungen, Eugen; Jordan, Alfons; Märk, Lukas; Mutschlechner, Paul; Schottkowsky, Ralf; Sulzer, Philipp; Crawford, James H.; Wisthaler, Armin

    2014-05-01

    We report the development of a compact Proton-Transfer-Reaction Time-of-Flight Mass Spectrometer (PTR-ToF-MS) in support of NASA's suborbital research program on the Earth's atmospheric composition. A lightweight, low mass resolution orthogonal acceleration ToF-MS was developed and combined with a conventional PTR ion source to measure volatile organic compounds (VOCs) in real time. The instrument was specially designed to resist aircraft vibrations and rough conditions during boundary layer flights, take-off and landing. The compact PTR-ToF-MS generates full mass spectral information at 1-second time resolution and below. With sensitivities of up to 150 cps/ppbv, typical 2σ detection limits in the range from 0.06 to 0.48 ppbv for a 1-second signal integration are achieved. A mass resolving power m/Δm of up to 1700 combined with an absolute mass accuracy and reproducibility of less than 3 mDa make it possible to distinguish isobaric ions at high time resolution, e.g. humidity- dependent isobaric background ions. The prototype instrument was successfully deployed for in-situ measurements of VOCs onboard the NASA P-3B Airborne Science Laboratory during two DISCOVER-AQ campaigns in the San Joaquin Valley, CA, and in Houston, TX, 2013. A 1-second time resolution results in a horizontal spatial resolution of typically 110 m and a vertical spatial resolution of typically 8 m which allowed for the quantitative detection of the entire suite of VOCs in strongly localized emission plumes from industrial, agricultural and biomass-burning sources. This work was funded by BMVIT / FFG-ALR in the frame of the Austrian Space Application Programme (ASAP 8, project 833451). Additional resources were provided through NASA's Earth Venture program (EV-1) and the NASA Postdoctoral Program (NPP).

  19. Neural correlates of encoding processes predicting subsequent cued recall and source memory.

    Science.gov (United States)

    Angel, Lucie; Isingrini, Michel; Bouazzaoui, Badiâa; Fay, Séverine

    2013-03-06

    In this experiment, event-related potentials were used to examine whether the neural correlates of encoding processes predicting subsequent successful recall differed from those predicting successful source memory retrieval. During encoding, participants studied lists of words and were instructed to memorize each word and the list in which it occurred. At test, they had to complete stems (the first four letters) with a studied word and then make a judgment of the initial temporal context (i.e. list). Event-related potentials recorded during encoding were segregated according to subsequent memory performance to examine subsequent memory effects (SMEs) reflecting successful cued recall (cued recall SME) and successful source retrieval (source memory SME). Data showed a cued recall SME on parietal electrode sites from 400 to 1200 ms and a late inversed cued recall SME on frontal sites in the 1200-1400 ms period. Moreover, a source memory SME was reported from 400 to 1400 ms on frontal areas. These findings indicate that patterns of encoding-related activity predicting successful recall and source memory are clearly dissociated.

  20. Comparison of LC-ESI-MS and GC-MS for the Analysis of a Synthetic Tabun Sample

    National Research Council Canada - National Science Library

    D'Agostino, Paul

    2003-01-01

    Packed capillary LC-ESI-MS and capillary column GC-MS were compared for the analysis of a synthetic tabun sample as each method has advantages for the analysis of samples containing chemical warfare...

  1. Analytical Method Details (MS): SE59_MS01 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available argeted metabolomic analysis using LC-QTOF-MS and the metabolome data processing of alignment, de-isotoping, noise cutting, and normalization was conducted as previously described. ...

  2. 3CE Methodology for Conducting a Modeling, Simulation, and Instrumentation Tool Capability Analysis

    Science.gov (United States)

    2010-05-01

    flRmurn I F )T:Ir,tir)l! MCr)lto.-lng DHin nttbli..’"Ollc:~ E,;m:a..liut .!,)’l’lt’Mn:l’lll.ll~ t Managemen t F unction a l Arem 1 .5 Toola na...a modeling, simulation, and instrumentation (MS&I) environment. This methodology uses the DoDAF product set to document operational and systems...engineering process were identified and resolved, such as duplication of data elements derived from DoDAF operational and system views used to

  3. A burnout prediction model based around char morphology

    Energy Technology Data Exchange (ETDEWEB)

    Tao Wu; Edward Lester; Michael Cloke [University of Nottingham, Nottingham (United Kingdom). School of Chemical, Environmental and Mining Engineering

    2006-05-15

    Several combustion models have been developed that can make predictions about coal burnout and burnout potential. Most of these kinetic models require standard parameters such as volatile content and particle size to make a burnout prediction. This article presents a new model called the char burnout (ChB) model, which also uses detailed information about char morphology in its prediction. The input data to the model is based on information derived from two different image analysis techniques. One technique generates characterization data from real char samples, and the other predicts char types based on characterization data from image analysis of coal particles. The pyrolyzed chars in this study were created in a drop tube furnace operating at 1300{sup o}C, 200 ms, and 1% oxygen. Modeling results were compared with a different carbon burnout kinetic model as well as the actual burnout data from refiring the same chars in a drop tube furnace operating at 1300{sup o}C, 5% oxygen, and residence times of 200, 400, and 600 ms. A good agreement between ChB model and experimental data indicates that the inclusion of char morphology in combustion models could well improve model predictions. 38 refs., 5 figs., 6 tabs.

  4. Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS

    Science.gov (United States)

    Chambers, Andrew G.; Percy, Andrew J.; Hardie, Darryl B.; Borchers, Christoph H.

    2013-09-01

    Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.

  5. Alkylation or Silylation for Analysis of Amino and Non-Amino Organic Acids by GC-MS?

    Directory of Open Access Journals (Sweden)

    Silas G. Villas-Bôas

    2011-01-01

    Full Text Available Gas chromatography–mass spectrometry (GC-MS is a widely used analytical technique in metabolomics. GC provides the highest resolution of any standard chromatographic separation method, and with modern instrumentation, retention times are very consistent between analyses. Electron impact ionization and fragmentation is generally reproducible between instruments and extensive libraries of spectra are available that enhance the identification of analytes. The major limitation is the restriction to volatile analytes, and hence the requirement to convert many metabolites to volatile derivatives through chemical derivatization. Here we compared the analytical performance of two derivatization techniques, silylation (TMS and alkylation (MCF, used for the analysis of amino and non-amino organic acids as well as nucleotides in microbial-derived samples. The widely used TMS derivatization method showed poorer reproducibility and instability during chromatographic runs while the MCF derivatives presented better analytical performance. Therefore, alkylation (MCF derivatization seems to be preferable for the analysis of polyfunctional amines, nucleotides and organic acids in microbial metabolomics studies.

  6. Detection of mono- and di-hexoses as metabolites of 4-bromoaniline using HPLC-TOF-MS/MS.

    Science.gov (United States)

    Major, H; Castro-Perez, J; Nicholson, J K; Wilson, I D

    2003-08-01

    1. The metabolic fate of 4-bromoaniline (4-BrA) was investigated in rat following intraperitoneal administration at 50 mg kg(-1) using HPLC-TOF-MS/MS. 2. The sensitivity provided by the use of TOF-MS/MS, aided by the distinctive isotope pattern resulting from the presence of the bromine substituent in the molecule, enabled the detection of many previously uncharacterized metabolites in the samples. 3. Several groups of minor metabolites were detected in the urine that corresponded to a number of isomeric hexose and di-hexose-containing conjugates (possibly glucosides and diglucosides) of 4-BrA. 4. As well as hexose and di-hexose conjugates of 4-BrA, several further groups of metabolites that also contained either a sulphamate or sulphate group in addition to the sugar moieties were also detected.

  7. Expedient data mining for nontargeted high-resolution LC-MS profiles of biological samples.

    Science.gov (United States)

    Hnatyshyn, Serhiy; Shipkova, Petia; Sanders, Mark

    2013-05-01

    The application of high-resolution LC-MS metabolomics for drug candidate toxicity screening reflects phenotypic changes of an organism caused by induced chemical interferences. Its success depends not only on the ability to translate the acquired analytical information into biological knowledge, but also on the timely delivery of the results to aid the decision making process in drug discovery and development. Recent improvements in analytical instrumentation have resulted in the ability to acquire extremely information-rich datasets. These new data collection abilities have shifted the bottleneck in the timeline of metabolomic studies to the data analysis step. This paper describes our approach to expedient data analysis of nontargeted high-resolution LC-MS profiles of biological samples. The workflow is illustrated with the example of metabolomics study of time-dependent fasting in male rats. The results from measurement of 220 endogenous metabolites in urine samples illustrate significant biochemical changes induced by fasting. The developed software enables the reporting of relative quantities of annotated components while maintaining practical turnaround times. Each component annotation in the report is validated using both calculated isotopic peaks patterns and experimentally determined retention time data on standards.

  8. Advanced Instrumentation and Measurement Techniques for Near Surface Flows

    Science.gov (United States)

    Cadel, Daniel R.

    The development of aerodynamic boundary layers on wind turbine blades is an important consideration in their performance. It can be quite challenging to replicate full scale conditions in laboratory experiments, and advanced diagnostics become valuable in providing data not available from traditional means. A new variant of Doppler global velocimetry (DGV) known as cross-correlation DGV is developed to measure boundary layer profiles on a wind turbine blade airfoil in the large scale Virginia Tech Stability Wind Tunnel. The instrument provides mean velocity vectors with reduced sensitivity to external conditions, a velocity measurement range from 0 ms-1 to over 3000 ms-1, and an absolute uncertainty. Monte Carlo simulations with synthetic signals reveal that the processing routine approaches the Cramer-Rao lower bound in optimized conditions. A custom probe-beam technique is implanted to eliminate laser flare for measuring boundary layer profiles on a DU96-W-180 wind turbine airfoil model. Agreement is seen with laser Doppler velocimetry data within the uncertainty estimated for the DGV profile. Lessons learned from the near-wall flow diagnostics development were applied to a novel benchmark model problem incorporating the relevant physical mechanisms of the high amplitude periodic turbulent flow experienced by turbine blades in the field. The model problem is developed for experimentally motivated computational model development. A circular cylinder generates a periodic turbulent wake, in which a NACA 63215b airfoil with a chord Reynolds number Rec = 170,000 is embedded for a reduced frequency k = pi f c/V = 1.53. Measurements are performed with particle image velocimetry on the airfoil suction side and in highly magnified planes within the boundary layer. Outside of the viscous region, the Reynolds stress profile is consistent with the prediction of Rapid Distortion Theory (RDT), confirming that the redistribution of normal stresses is an inviscid effect. The

  9. Global proteomics profiling improves drug sensitivity prediction: results from a multi-omics, pan-cancer modeling approach.

    Science.gov (United States)

    Ali, Mehreen; Khan, Suleiman A; Wennerberg, Krister; Aittokallio, Tero

    2018-04-15

    Proteomics profiling is increasingly being used for molecular stratification of cancer patients and cell-line panels. However, systematic assessment of the predictive power of large-scale proteomic technologies across various drug classes and cancer types is currently lacking. To that end, we carried out the first pan-cancer, multi-omics comparative analysis of the relative performance of two proteomic technologies, targeted reverse phase protein array (RPPA) and global mass spectrometry (MS), in terms of their accuracy for predicting the sensitivity of cancer cells to both cytotoxic chemotherapeutics and molecularly targeted anticancer compounds. Our results in two cell-line panels demonstrate how MS profiling improves drug response predictions beyond that of the RPPA or the other omics profiles when used alone. However, frequent missing MS data values complicate its use in predictive modeling and required additional filtering, such as focusing on completely measured or known oncoproteins, to obtain maximal predictive performance. Rather strikingly, the two proteomics profiles provided complementary predictive signal both for the cytotoxic and targeted compounds. Further, information about the cellular-abundance of primary target proteins was found critical for predicting the response of targeted compounds, although the non-target features also contributed significantly to the predictive power. The clinical relevance of the selected protein markers was confirmed in cancer patient data. These results provide novel insights into the relative performance and optimal use of the widely applied proteomic technologies, MS and RPPA, which should prove useful in translational applications, such as defining the best combination of omics technologies and marker panels for understanding and predicting drug sensitivities in cancer patients. Processed datasets, R as well as Matlab implementations of the methods are available at https://github.com/mehr-een/bemkl-rbps. mehreen

  10. Investigating the interactive role of stressful life events, reinforcement sensitivity and personality traits in prediction of the severity of Multiple Sclerosis (MS symptoms

    Directory of Open Access Journals (Sweden)

    2017-06-01

    Full Text Available Background & Objective: Multiple sclerosis is a chronic neurological condition recognized by demyelination in the central nervous system. The present study was conducted to investigate the interactive role of stressful life events, reinforcement sensitivity, and personality traits in prediction of the severity of symptoms of Multiple sclerosis (MS symptoms. Materials & Methods: This is a correlational study whose statistical population consisted of all the patients suffering from Multiple Sclerosis in Shiraz in the first half of 1394, among whom 162 patients were included in this research by means of purposive sampling method. Five-Factor Personality Inventory, Jackson Personality Inventory, Stressful Life Events Scale, and Expanded Disability Status Scale (EDSS were utilised as research tools. In order to analyze the data, descriptive and inferential methods were used. The data were analysed using Pearson correlation and hierarchical regression. Results: The findings revealed that stressful life events (β = 0.41, p <0.001, Behavioral Inhibition System (β = 0.26, p<0.05, and neuroticism index (β = 0.92, p <0.05 were able to predict variance of scores of the severity of symptoms of Multiple Sclerosis significantly. Conclusion: Stressful life events, Behavioral Inhibition System, and neuroticism showed a significant relationship with the severity of symptoms of Multiple Sclerosis; thus, it seems that interaction of personality traits and environmental conditions are among influential factors of the severity of symptoms of Multiple Sclerosis. This fact implies that individuals' personal traits play an eminent role in the progression of the disease.

  11. Determining degree of roasting in cocoa beans by artificial neural network (ANN)-based electronic nose system and gas chromatography/mass spectrometry (GC/MS).

    Science.gov (United States)

    Tan, Juzhong; Kerr, William L

    2018-08-01

    Roasting is a critical step in chocolate processing, where moisture content is decreased and unique flavors and texture are developed. The determination of the degree of roasting in cocoa beans is important to ensure the quality of chocolate. Determining the degree of roasting relies on human specialists or sophisticated chemical analyses that are inaccessible to small manufacturers and farmers. In this study, an electronic nose system was constructed consisting of an array of gas sensors and used to detect volatiles emanating from cocoa beans roasted for 0, 20, 30 and 40 min. The several signals were used to train a three-layer artificial neural network (ANN). Headspace samples were also analyzed by gas chromatography/mass spectrometry (GC/MS), with 23 select volatiles used to train a separate ANN. Both ANNs were used to predict the degree of roasting of cocoa beans. The electronic nose had a prediction accuracy of 94.4% using signals from sensors TGS 813, 826, 822, 830, 830, 2620, 2602 and 2610. In comparison, the GC/MS predicted the degree of roasting with an accuracy of 95.8%. The electronic nose system is able to predict the extent of roasting, as well as a more sophisticated approach using GC/MS. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  12. siMS Score: Simple Method for Quantifying Metabolic Syndrome.

    Science.gov (United States)

    Soldatovic, Ivan; Vukovic, Rade; Culafic, Djordje; Gajic, Milan; Dimitrijevic-Sreckovic, Vesna

    2016-01-01

    To evaluate siMS score and siMS risk score, novel continuous metabolic syndrome scores as methods for quantification of metabolic status and risk. Developed siMS score was calculated using formula: siMS score = 2*Waist/Height + Gly/5.6 + Tg/1.7 + TAsystolic/130-HDL/1.02 or 1.28 (for male or female subjects, respectively). siMS risk score was calculated using formula: siMS risk score = siMS score * age/45 or 50 (for male or female subjects, respectively) * family history of cardio/cerebro-vascular events (event = 1.2, no event = 1). A sample of 528 obese and non-obese participants was used to validate siMS score and siMS risk score. Scores calculated as sum of z-scores (each component of metabolic syndrome regressed with age and gender) and sum of scores derived from principal component analysis (PCA) were used for evaluation of siMS score. Variants were made by replacing glucose with HOMA in calculations. Framingham score was used for evaluation of siMS risk score. Correlation between siMS score with sum of z-scores and weighted sum of factors of PCA was high (r = 0.866 and r = 0.822, respectively). Correlation between siMS risk score and log transformed Framingham score was medium to high for age groups 18+,30+ and 35+ (0.835, 0.707 and 0.667, respectively). siMS score and siMS risk score showed high correlation with more complex scores. Demonstrated accuracy together with superior simplicity and the ability to evaluate and follow-up individual patients makes siMS and siMS risk scores very convenient for use in clinical practice and research as well.

  13. The limitations on organic detection in Mars-like soils by thermal volatilization-gas chromatography-MS and their implications for the Viking results.

    Science.gov (United States)

    Navarro-González, Rafael; Navarro, Karina F; de la Rosa, José; Iñiguez, Enrique; Molina, Paola; Miranda, Luis D; Morales, Pedro; Cienfuegos, Edith; Coll, Patrice; Raulin, François; Amils, Ricardo; McKay, Christopher P

    2006-10-31

    The failure of Viking Lander thermal volatilization (TV) (without or with thermal degradation)-gas chromatography (GC)-MS experiments to detect organics suggests chemical rather than biological interpretations for the reactivity of the martian soil. Here, we report that TV-GC-MS may be blind to low levels of organics on Mars. A comparison between TV-GC-MS and total organics has been conducted for a variety of Mars analog soils. In the Antarctic Dry Valleys and the Atacama and Libyan Deserts we find 10-90 mug of refractory or graphitic carbon per gram of soil, which would have been undetectable by the Viking TV-GC-MS. In iron-containing soils (jarosites from Rio Tinto and Panoche Valley) and the Mars simulant (palogonite), oxidation of the organic material to carbon dioxide (CO(2)) by iron oxides and/or their salts drastically attenuates the detection of organics. The release of 50-700 ppm of CO(2) by TV-GC-MS in the Viking analysis may indicate that an oxidation of organic material took place. Therefore, the martian surface could have several orders of magnitude more organics than the stated Viking detection limit. Because of the simplicity of sample handling, TV-GC-MS is still considered the standard method for organic detection on future Mars missions. We suggest that the design of future organic instruments for Mars should include other methods to be able to detect extinct and/or extant life.

  14. The limitations on organic detection in Mars-like soils by thermal volatilization–gas chromatography–MS and their implications for the Viking results

    Science.gov (United States)

    Navarro-González, Rafael; Navarro, Karina F.; de la Rosa, José; Iñiguez, Enrique; Molina, Paola; Miranda, Luis D.; Morales, Pedro; Cienfuegos, Edith; Coll, Patrice; Raulin, François; Amils, Ricardo; McKay, Christopher P.

    2006-01-01

    The failure of Viking Lander thermal volatilization (TV) (without or with thermal degradation)–gas chromatography (GC)–MS experiments to detect organics suggests chemical rather than biological interpretations for the reactivity of the martian soil. Here, we report that TV–GC–MS may be blind to low levels of organics on Mars. A comparison between TV–GC–MS and total organics has been conducted for a variety of Mars analog soils. In the Antarctic Dry Valleys and the Atacama and Libyan Deserts we find 10–90 μg of refractory or graphitic carbon per gram of soil, which would have been undetectable by the Viking TV–GC–MS. In iron-containing soils (jarosites from Rio Tinto and Panoche Valley) and the Mars simulant (palogonite), oxidation of the organic material to carbon dioxide (CO2) by iron oxides and/or their salts drastically attenuates the detection of organics. The release of 50–700 ppm of CO2 by TV–GC–MS in the Viking analysis may indicate that an oxidation of organic material took place. Therefore, the martian surface could have several orders of magnitude more organics than the stated Viking detection limit. Because of the simplicity of sample handling, TV–GC–MS is still considered the standard method for organic detection on future Mars missions. We suggest that the design of future organic instruments for Mars should include other methods to be able to detect extinct and/or extant life. PMID:17060639

  15. Investigation of a breathing surrogate prediction algorithm for prospective pulmonary gating

    International Nuclear Information System (INIS)

    White, Benjamin M.; Low, Daniel A.; Zhao Tianyu; Wuenschel, Sara; Lu, Wei; Lamb, James M.; Mutic, Sasa; Bradley, Jeffrey D.; El Naqa, Issam

    2011-01-01

    Purpose: A major challenge of four dimensional computed tomography (4DCT) in treatment planning and delivery has been the lack of respiration amplitude and phase reproducibility during image acquisition. The implementation of a prospective gating algorithm would ensure that images would be acquired only during user-specified breathing phases. This study describes the development and testing of an autoregressive moving average (ARMA) model for human respiratory phase prediction under quiet respiration conditions. Methods: A total of 47 4DCT patient datasets and synchronized respiration records was utilized in this study. Three datasets were used in model development and were removed from further evaluation of the ARMA model. The remaining 44 patient datasets were evaluated with the ARMA model for prediction time steps from 50 to 1000 ms in increments of 50 and 100 ms. Thirty-five of these datasets were further used to provide a comparison between the proposed ARMA model and a commercial algorithm with a prediction time step of 240 ms. Results: The optimal number of parameters for the ARMA model was based on three datasets reserved for model development. Prediction error was found to increase as the prediction time step increased. The minimum prediction time step required for prospective gating was selected to be half of the gantry rotation period. The maximum prediction time step with a conservative 95% confidence criterion was found to be 0.3 s. The ARMA model predicted peak inhalation and peak exhalation phases significantly better than the commercial algorithm. Furthermore, the commercial algorithm had numerous instances of missed breath cycles and falsely predicted breath cycles, while the proposed model did not have these errors. Conclusions: An ARMA model has been successfully applied to predict human respiratory phase occurrence. For a typical CT scanner gantry rotation period of 0.4 s (0.2 s prediction time step), the absolute error was relatively small, 0

  16. Measurement of trace levels of antibiotics in river water using on-line enrichment and triple-quadrupole LC-MS/MS.

    Science.gov (United States)

    Dinh, Quoc Tuc; Alliot, Fabrice; Moreau-Guigon, Elodie; Eurin, Joëlle; Chevreuil, Marc; Labadie, Pierre

    2011-09-15

    This study presents the development of an automated on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of 23 antibiotics in environmental water samples. After optimisation of LC-MS/MS conditions, SPE parameters such as sorbent type, sample pH or sample volume were optimised. Antibiotic recoveries ranged from 64% to 98% and compared favourably with those achieved using off-line SPE. Limits of detection were in the range 0.5-13.7 ng L(-1). This on-line SPE-LC-MS/MS procedure was applied to the analysis of water samples taken in three rivers within the Seine River basin, near Paris (France). The obtained results revealed the occurrence of 12 antibiotics, including tylosin, erythromycin, tetracycline, amoxicillin, trimethoprim, sulfamethoxazole, oxolinic acid, flumequine, norfloxacin, ciprofloxacin, ofloxacin, and vancomycin (2-1435 ng L(-1)). Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Instrumental analytical techniques in geochemistry: Requirements and applications

    International Nuclear Information System (INIS)

    Willis, J.P.

    1986-01-01

    Geochemists must analyse an extremely wide range of terrestrial and planetary materials. The instrumental techniques necessary to cope with this difficult task are considered. The most important analytical techniques in use by the geochemist today are AAS, ICP-OES, INAA, MSID and XRFS, and the electron microscope for in situ mineral analysis. Some applications of these techniques to solving major problems in geochemistry are discussed. The importance of certified reference materials and of high quality geochemical data are emphasized. It is concluded that the general quality of trace element data has improved over the past 25 years, as a direct result of the application of modern instrumental techniques. Surprisingly, the quality of data reported for certain major elements has deteriorated over that time, when compared with data obtainable by classical chemical methods. Predictions are made concerning the instrumentation needs of the next generation of geochemists. (orig.) [de

  18. Predicting Falls in People with Multiple Sclerosis: Fall History Is as Accurate as More Complex Measures

    Directory of Open Access Journals (Sweden)

    Michelle H. Cameron

    2013-01-01

    Full Text Available Background. Many people with MS fall, but the best method for identifying those at increased fall risk is not known. Objective. To compare how accurately fall history, questionnaires, and physical tests predict future falls and injurious falls in people with MS. Methods. 52 people with MS were asked if they had fallen in the past 2 months and the past year. Subjects were also assessed with the Activities-specific Balance Confidence, Falls Efficacy Scale-International, and Multiple Sclerosis Walking Scale-12 questionnaires, the Expanded Disability Status Scale, Timed 25-Foot Walk, and computerized dynamic posturography and recorded their falls daily for the following 6 months with calendars. The ability of baseline assessments to predict future falls was compared using receiver operator curves and logistic regression. Results. All tests individually provided similar fall prediction (area under the curve (AUC 0.60–0.75. A fall in the past year was the best predictor of falls (AUC 0.75, sensitivity 0.89, specificity 0.56 or injurious falls (AUC 0.69, sensitivity 0.96, specificity 0.41 in the following 6 months. Conclusion. Simply asking people with MS if they have fallen in the past year predicts future falls and injurious falls as well as more complex, expensive, or time-consuming approaches.

  19. Determination of isosteviol by LC-MS/MS and its application for evaluation of pharmacokinetics of isosteviol in rat

    Directory of Open Access Journals (Sweden)

    Bazargan M.

    2007-06-01

    Full Text Available Isosteviol has been found to have potential preventive or therapeutic effects against hypertension, ischemia reperfusion injury, diabetes and cancer, but little is known about the pharmacokinetics (PK of the compound. The aim of this study was to develop a liquid chromatographic-tandem mass spectrometric (LC-MS/MS method for determination of isosteviol in rat plasma and to assess in a preliminary manner the PK of isosteviol after intravenous bolus injection.Ions of analytes were generated using electro-spray ionization and detected in the positive-ion mode in LC-MS/MS. Multiple reaction monitoring was performed, using the precursor product ion combination for isosteviol m/z 319.4→273.4. Progesterone was used as an internal standard. Nitrogen was used as the nebulising gas and unit resolution was set for Q1 and Q3. Isosteviol solution was injected through the penile vein of rats at a dose of 8 mg/kg. Blood samples were collected from a jugular vein cannula. The PK parameters were calculated using a two - compartment PK model.The LC-MS/MS assay for isosteviol in rat plasma was linear over the range of 0.5-80 μg/ml. The terminal half life of isosteviol (t 1/2 was 406 ± 31.7 min and clearance (CL was 2.9 ± 0.3 ml/min/kg. A sensitive LC-MS/MS assay for isosteviol in plasma has been successfully established and used in a preliminary PK evaluation of isosteviol in rats.

  20. ICP-MS/MS-Based Ionomics: A Validated Methodology to Investigate the Biological Variability of the Human Ionome.

    Science.gov (United States)

    Konz, Tobias; Migliavacca, Eugenia; Dayon, Loïc; Bowman, Gene; Oikonomidi, Aikaterini; Popp, Julius; Rezzi, Serge

    2017-05-05

    We here describe the development, validation and application of a quantitative methodology for the simultaneous determination of 29 elements in human serum using state-of-the-art inductively coupled plasma triple quadrupole mass spectrometry (ICP-MS/MS). This new methodology offers high-throughput elemental profiling using simple dilution of minimal quantity of serum samples. We report the outcomes of the validation procedure including limits of detection/quantification, linearity of calibration curves, precision, recovery and measurement uncertainty. ICP-MS/MS-based ionomics was used to analyze human serum of 120 older adults. Following a metabolomic data mining approach, the generated ionome profiles were subjected to principal component analysis revealing gender and age-specific differences. The ionome of female individuals was marked by higher levels of calcium, phosphorus, copper and copper to zinc ratio, while iron concentration was lower with respect to male subjects. Age was associated with lower concentrations of zinc. These findings were complemented with additional readouts to interpret micronutrient status including ceruloplasmin, ferritin and inorganic phosphate. Our data supports a gender-specific compartmentalization of the ionome that may reflect different bone remodelling in female individuals. Our ICP-MS/MS methodology enriches the panel of validated "Omics" approaches to study molecular relationships between the exposome and the ionome in relation with nutrition and health.