  1. Single injection 51Cr EDTA plasma clearance determination in children using capillary blood samples

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Christoffersen, J.

    1977-01-01

    The reliability of a determination of the total 51 Cr EDTA plasma clearance (e) (and with it the glomerular filtration rate), by a simplified single injection method (injected dose: 4.5 μCi per kg b.w.) using capillary blood samples (0.2 ml), was investigated in twenty children. Clearance values determined from capillary blood samples did not differ significantly from those measured simultaneously from venous blood samples, the mean ratio+-SD being 1.02+-0.06(n = 10). The reproducibility (total day-to-day variation) of E determined from capillary blood samples was 6.7% in children with decreased renal function (n = 3) and 6.9% in children with normal renal function (n = 7). The present data indicate that the use of capillary blood samples is an accurate and very precise approach for determination of E in children. (Auth.)

  2. 51Cr-EDTA plasma clearance in severe renal failure determined by one plasma sample

    DEFF Research Database (Denmark)

    Kamper, A L; Nielsen, S L

    1989-01-01

    Two hundred and thirty-four measurements of standard 51Cr-EDTA plasma clearance were made in 50 patients with severe chronic renal failure. Based on these data two calculation methods were attempted using one plasma sample drawn 24 h after injection of 51Cr-EDTA. One of the methods used the 'one...... at zero-time was derived from injected dose and body surface area. This method might provide values 1.5 ml/min below or 0.8 ml/min above the established method of 51Cr-EDTA plasma clearance, which would be acceptable for clinical purposes. It is concluded that exact plasma clearance of 51Cr-EDTA in severe...... renal dysfunction (estimated clearance values below 21 ml/min) may be determined with adequate precision by one plasma sample drawn at 24 h after injection of the tracer without sampling at 5 h. This appears to be a very practical simplification....

  3. Over-estimation of glomerular filtration rate by single injection [51Cr]EDTA plasma clearance determination in patients with ascites

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Brøchner-Mortensen, J; Malchow-Møller, A

    1980-01-01

    The total plasma (Clt) and the renal plasma (Clr) clearances of [51Cr]EDTA were determined simultaneously in nine patients with ascites due to liver cirrhosis. Clt (mean 78 ml/min, range 34-115 ml/min) was significantly higher than Clr (mean 52 ml/min, range 13-96 ml/min, P ... fluid-plasma activity ratio of [51Cr]EDTA increased throughout the investigation period (5h). The results suggest that [51Cr]EDTA equilibrates slowly with the peritoneal space which indicates that Clt will over-estimate the glomerular filtration rate by approximately 20 ml/min in patients with ascites...

  4. [51Cr]EDTA plasma clearance and endogenous creatinine clearance in advanced renal insufficiency

    International Nuclear Information System (INIS)

    Svendsen, U.G.; Munck, O.; Czartoryski, A.; Stafanger, G.

    1978-01-01

    Comparison of [ 51 Cr]EDTA plasma clearance corrected for extrarenal elimination with 24 h endogenous creatinine clearance in patients with advanced renal failure showed that the corrected [ 51 Cr]EDTA clearance was lower than creatinine clearance, and thus might be a better approximation to the glomerular filtration rate in uraemic patients. The corrections cannot be used on [ 51 Cr]EDTA clearance values below the mean extrarenal clearance, averaging 3.7 ml/min. (Auth.)

  5. Optimum time of blood sampling for determination of glomerular filtration rate by single-injection [51Cr]EDTA plasma clearance

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Roedbro, P.

    1976-01-01

    We have investigated the influence on reproducibility of total [ 51 Cr]EDTA plasma clearance (E) of various times and numbers of blood samples in patients with normal (13 patients) and low (14 patients) renal function. The study aims at fixing a clinically useful procedure suitable for all levels of renal function. Six different types of E were evaluated with time periods for blood sampling between 3 and 5 h after tracer injection, and the variation from counting radioactivity, s 1 , was determined as part of the total variation, s 2 . Optimum mean time, t(E), for blood sampling was calculated as a function of E, as the mean time giving the least change in E for a given change in the 'final slope' of the plasma curve. For patients with normal E, s 1 did not contribute significantly to s 2 , and t(E) was about 2h. For patients with low renal function s 1 contributed significantly to s 2 , and t(E) increased steeply with decreasing E. The relative error in s 1 from fixed Etypes was calculated for all levels of renal function. The results indicate that blood sampling individualized according to predicted E values is not necessary. A sufficient precision of E can be achieved for all function levels from three blood samples drawn at 180, 240, and 300 min after injection. (Auth.)

  6. Comparison between total and renal plasma clearance of [51Cr]EDTA

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Roedbro, P.

    1976-01-01

    The total plasma (E 1 ) and renal plasma (E 2 ) clearances of [ 51 Cr]EDTA were measured simultaneously in 40 patients with a wide range of renal function. The regression equation was E 1 = 0.997E 2 + 4.1; the slope of the regression line was not significantly different from 1.00, and the intercept differed significantly from zero. The results suggest that [ 51 Cr]EDTA has a significant extrarenal clearance of approximately 4 ml/min, independent of renal function. The data are used to correct the total [ 51 Cr]EDTA plasma clearance, measured by a simplified method, to yield a rapid, accurate and precise measurement of glomerular filtration rate for routine clinical use. (Auth.)

  7. Gamma-variate plasma clearance versus urinary plasma clearance of 51Cr-EDTA in patients with cirrhosis with and without fluid retention

    DEFF Research Database (Denmark)

    Fuglsang, Stefan; Henriksen, Ulrik L; Hansen, Hanne Boskov

    2017-01-01

    In patients with fluid retention, the plasma clearance of (51) Cr-EDTA (Clexp obtained by multiexponential fit) may overestimate the glomerular filtration rate (GFR). The present study was undertaken to compare a gamma-variate plasma clearance (Clgv) with the urinary plasma clearance of (51) Cr......-EDTA (Clu ) in patients with cirrhosis with and without fluid retention. A total of 81 patients with cirrhosis (22 without fluid retention, 59 with ascites) received a quantitative intravenous injection of (51) Cr-EDTA followed by plasma and quantitative urinary samples for 5 h. Clgv was determined from...... the injected dose relative to the plasma concentration-time area, obtained by a gamma-variate iterative fit. Clexp and Clu were determined by standard technique. In patients without fluid retention, Clgv , Clexp and Clu were closely similar. The difference between Clgv and Clu (Clgv - Clu = ΔCl) was mean -0...

  8. Assessment of glomerular filtration rate in diabetic nephropathy using the plasma clearance of 51Cr-EDTA

    DEFF Research Database (Denmark)

    Hansen, H P; Rossing, P; Mathiesen, E R

    1998-01-01

    Plasma clearance of 51Cr-EDTA is widely used to assess the glomerular filtration rate (GFR) in diabetic nephropathy. Originally, the ratio between the intravenously injected amount of tracer and the total area under the plasma concentration curve was used for the calculation of total 51Cr...... and rate of decline in GFR based upon these three methods. Bland & Altman plots were used to illustrate the range of agreement. We investigated 76 insulin-dependent diabetic (IDDM) patients with microalbuminuria or diabetic nephropathy. GFR was measured after a single intravenous injection of 3.7 MBq 51Cr...

  9. Selection of blood sampling times for determination of 51Cr-EDTA clearance in a screeening procedure

    International Nuclear Information System (INIS)

    Gullquist, R.; Askergren, A.; Brandt, R.; Silk, B.; Strandell, T.; Huddinge University Hospital

    1983-01-01

    In a group of 44 construction workers various blood sampling protocols were compared with regard to variability of the 51 Cr-EDTA clearance on repeated determinations. A comparison was also made among the different blood sampling protocols with a reference method using Simpson's formula in the area calculation. A double slope method lasting for two and a half hours was finally choosen and suggested as a screening procedure in industrial environment with blood sampling at 5, 15, 90, 120, 135 and 150 minutes after injection and with the patient resting in a semirecumbent position. (orig.) [de

  10. 'Scan GFR' as an alternative to 51Cr-EDTA clearance

    International Nuclear Information System (INIS)

    Osman, E.A.; Clarke, M.B.; Barrett, J.J.; Parsons, V.; Dulwich Hospital, London

    1989-01-01

    In this report 39 patients had their GFR assessed by 51 Cr-EDTA in a single shot-multiple sampling technique and also by measuring the quantitative renal uptake of 99m Tc-DTPA during a standard renal imaging test. The results showed a correlation coefficient of 0.96 between the two techniques. By using linear regression analysis the GFR was derived from the % renal uptake of DTPA in a further series of 24 patients in whom the 51 Cr-EDTA method was also employed. The two methods were compared and showed a correlation coefficient of 0.94 with a mean GFR difference of 7 ± 4.5 ml/min over a 51 Cr-EDTA range of 38-150 ml/min. (orig.) [de

  11. Study of the post-equilibrium slope approximation in the calculation of glomerular filtration rate using the 51Cr-EDTA single injection technique

    International Nuclear Information System (INIS)

    Nimmon, C.C.; McAlister, J.M.; Hickson, B.; Cattell, W.R.

    1975-01-01

    A comparison of methods for calculating the renal clearance of EDTA from the plasma disappearance curve, after a single injection, has been made. Measurements were made on 38 patients, using external monitoring and venous blood sampling techniques, over a period of 24 h after an injection of 100 μCi of 51 Cr-EDTA. The results indicate that the period 3 - 6 h after injection is suitable for sampling the post-equilibrium part of the plasma disappearance curve for values of the glomerular filtration rate (GFR) in the range 0 - 140 ml/min. It was also found that, to within the individual measurement errors, the values of the clearance calculated by using the post-equilibrium period only (PES clearance) can be considered to show a constant proportionality to the values calculated by using the entire plasma disappearance curve (total clearance). (author)

  12. Comparative study of conventional PAH and inulin clearance and slope clearance of 131I-o-hippuric acid and 51Cr-EDTA

    International Nuclear Information System (INIS)

    Berghaeuser, H.

    1981-01-01

    ''Classic'' PAH and inulin clearance were determined in 81 patients with renal anomalies or renal diseases of different genesis and severity. In addition, radioisotope nephrography was carried out after administration of I-131-o-hippuric acid, followed by administration of Cr-51-EDTA. The activity decrease was recorded by a sensor located over the patient's right shoulder; the activities of a serum sample and of the urine excreted after 21 or 31 min were measured, and the findings were compared with those of the classic method. The clearance data calculated on the basis of the soulder measurements were hardly compatible with those of the conventional method in the case of 131 I-o-hippuric acid (r=0.54) and totally incompatible in the case of 51 Cr-EDTA. This means that the method described by Oberhausen is the only accurate method available for a quantitative assessment of the renal function on the basis of measurements of the activity decrease in the body. The activity of urine excreted after 31 min ( 131 I-hippuric acid:r=0.992, 51 Cr-EDTA:r=0.79) is a sufficiently accurate parameter although it is inaccurate at PAH clearance, values > 130 ml/min and inulin clearance values > 30 ml/min. Of the many parameters of radioisotope nephrogram curves, in the case of 131 I-o-hippuric acid only the parameters related to the ascent between 48 and 120 sec or to the secant ascent yield sufficient quantitative information for certain functional regions (r=0.9 resp. r=0.93). In the case of 51 Cr-EDTA, semiquantitative information on the renal function can be obtained by constructing secants on the nephrogram curves (r=0.7 resp. r=0.72). Here as in the case of 131 I-hippuric acid, the contribution of each kidney can be determined individually from the functional analysis of both kidneys. (orig.) [de

  13. Glomerular filtration rate measured by {sup 51}Cr-EDTA clearance: evaluation of captopril-induced changes in hypertensive patients with and without renal artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Chaves, Anna Alice Rolim; Buchpiguel, Carlos Alberto; Praxedes, Jose Nery; Bortolotto, Luiz Aparecido; Sapienza, Marcelo Tatit, E-mail: annaalice100@yahoo.com.b [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Dept. de Neurologia

    2010-07-01

    Introduction: renal artery stenosis can lead to renovascular hypertension; however, the detection of stenosis alone does not guarantee the presence of renovascular hypertension. Renovascular hypertension depends on activation of the renin-angiotensin system, which can be detected by functional tests such as captopril renal scintigraphy. A method that allows direct measurement of the baseline and post-captopril glomerular filtration rate using chromium-51 labeled ethylenediamine tetraacetic acid ({sup 51}Cr-EDTA) could add valuable information to the investigation of hypertensive patients with renal artery stenosis. The purposes of this study were to create a protocol to measure the baseline and post-captopril glomerular filtration rate using {sup 51}Cr-EDTA, and to verify whether changes in the glomerular filtration rate permit differentiation between hypertensive patients with and without renal artery stenosis. Methods: this prospective study included 41 consecutive patients with poorly controlled severe hypertension. All patients had undergone a radiological investigation of renal artery stenosis within the month prior to their inclusion. The patients were divided into two groups: patients with (n=21) and without renal artery stenosis, (n=20). In vitro glomerular filtration rate analysis ({sup 51}Cr-EDTA) and {sup 99m}Tc-DMSA scintigraphy were performed before and after captopril administration in all patients. Results: the mean baseline glomerular filtration rate was 48.6+-21.8 ml/kg/1.73 m{sup 2} in the group with renal artery stenosis, which was significantly lower than the GFR of 65.1+-28.7 ml/kg/1.73m{sup 2} in the group without renal artery stenosis (p=0.04). Captopril induced a significant reduction of the glomerular filtration rate in the group with renal artery stenosis (to 32.6+-14.8 ml/kg/1.73m{sup 2}, p=0.001) and an insignificant change in the group without RAS (to 62.2+-23.6 ml/kg/1.73m{sup 2}, p=0.68). Scintigraphy with technetium-99m dimercapto

  14. Glomerular filtration rate measured by 51Cr-EDTA clearance: evaluation of captopril-induced changes in hypertensive patients with and without renal artery stenosis

    International Nuclear Information System (INIS)

    Chaves, Anna Alice Rolim; Buchpiguel, Carlos Alberto; Praxedes, Jose Nery; Bortolotto, Luiz Aparecido; Sapienza, Marcelo Tatit

    2010-01-01

    Introduction: renal artery stenosis can lead to renovascular hypertension; however, the detection of stenosis alone does not guarantee the presence of renovascular hypertension. Renovascular hypertension depends on activation of the renin-angiotensin system, which can be detected by functional tests such as captopril renal scintigraphy. A method that allows direct measurement of the baseline and post-captopril glomerular filtration rate using chromium-51 labeled ethylenediamine tetraacetic acid ( 51 Cr-EDTA) could add valuable information to the investigation of hypertensive patients with renal artery stenosis. The purposes of this study were to create a protocol to measure the baseline and post-captopril glomerular filtration rate using 51 Cr-EDTA, and to verify whether changes in the glomerular filtration rate permit differentiation between hypertensive patients with and without renal artery stenosis. Methods: this prospective study included 41 consecutive patients with poorly controlled severe hypertension. All patients had undergone a radiological investigation of renal artery stenosis within the month prior to their inclusion. The patients were divided into two groups: patients with (n=21) and without renal artery stenosis, (n=20). In vitro glomerular filtration rate analysis ( 51 Cr-EDTA) and 99m Tc-DMSA scintigraphy were performed before and after captopril administration in all patients. Results: the mean baseline glomerular filtration rate was 48.6±21.8 ml/kg/1.73 m 2 in the group with renal artery stenosis, which was significantly lower than the GFR of 65.1±28.7 ml/kg/1.73m 2 in the group without renal artery stenosis (p=0.04). Captopril induced a significant reduction of the glomerular filtration rate in the group with renal artery stenosis (to 32.6±14.8 ml/kg/1.73m 2 , p=0.001) and an insignificant change in the group without RAS (to 62.2±23.6 ml/kg/1.73m 2 , p=0.68). Scintigraphy with technetium-99m dimercapto-succinic acid (DMSA) did not show

  15. Arterio-venous concentration difference of [51Cr]EDTA after a single injection in man. Significance of renal function and local blood flow

    DEFF Research Database (Denmark)

    Rehling, M; Hyldstrup, L; Henriksen, Jens Henrik Sahl

    1989-01-01

    , whereas the difference was very sensitive to even small changes in forearm blood flow within the physiological range. For measurement of renal plasma clearance it is recommended to use one long period: from the time of injection until 300 min p.i. or longer. If the clearance period is too short, the use...... introduced in the measurement of renal plasma clearance and total plasma clearance by using venous blood samples instead of arterial. In 13 patients with GFR ranging from 29 to 150 ml min-1, Ca was higher than Cv immediately after the injection. After mean 38 min (range 12-82 min) the two curves crossed...... of venous samples will overestimate the true renal clearance. Plasma clearance determined by venous and arterial blood samples does not differ significantly as long as the concentration is followed from the time of injection and a long period is applied. When simplified plasma clearance techniques are used...

  16. Total plasma clearance versus urinary plasma clearance of (51)Cr-EDTA in patients with cirrhosis with and without fluid retention

    DEFF Research Database (Denmark)

    Henriksen, Ulrik Lütken; Hansen, Hanne B; Ring-Larsen, Helmer

    2015-01-01

    the injected dose relative to the plasma concentration-time area, extrapolated to infinity. ClU was determined as urinary excretion relative to the plasma concentration-time area up to voiding. Results. In patients without fluid retention, the difference between ClP and ClU (ClP - ClU = ClΔ) was mean 4.5 m...

  17. What method to use for the renal clearance with {sup 51}Cr-E.D.T.A.: retrospective study among 1157 adults and 286 children; Quelle methode de mesure utiliser pour la clairance renale au 51Cr-EDTA: etude retrospective chez 1157 adultes et 286 enfants

    Energy Technology Data Exchange (ETDEWEB)

    Lacoeuille, F.; Machefert, N.; Vervueren, L.; Berthelot, C.; Rakotonirina, H.; Le Jeune, J.J.; Couturier, O. [CHU d' Angers, Service de medecine nucleaire, 49 (France); Drablier, G.; Cahouet-Vannier, A. [CHU d' Angers, Service de pharmacie, 49 (France); Denizot, B. [CH Annemasse, service de medecine nucleaire, 74 (France)

    2010-07-01

    Purpose: in the objective to make our practices evolve and to limit the numbers of sampling for patients, we searched to determine if the methods used (4,2 or 1 sampling) to measure the renal clearance to {sup 51}Cr-EDTA give results comparable on the population of patients concerned by this examination. Conclusions: This study allowed to enlighten interchangeability between the four points and two points method for the population studied. It allows to consider a change in our practice for the profit of a two points methods. (N.C.)

  18. Measurement of intestinal permeability using 51Cr-EDTA

    International Nuclear Information System (INIS)

    Peled, Y.; Watz, C.; Gilat, T.

    1985-01-01

    Intestinal permeability tests are a new class of tests of which the 51 Cr-EDTA seemed the easiest to perform. The authors have evaluated the 8- and 24-h urinary excretion of ingested 51 Cr-EDTA in 38 subjects. Twenty-seven patients with diseases not affecting the integrity of the small bowel served as controls. The test group consisted of two patients with celiac, six with Crohn's disease, and three with ulcerative colitis. Nineteen (70.37%) of the control patients had an abnormal test (more than 2.6% in 24 h). The patients with ulcerative colitis had normal excretion (mean 1.95% in 24 h). The patients with celiac disease had an elevated excretion (mean 3.62% in 24 h) and five out of six patients with Crohn's disease also had an increased excretion (mean 6.2% in 24 h). The elevated 51 Cr-EDTA excretion in the control patients casts serious doubts on the validity of the test. Possible causes for abnormal excretion in the controls include various medications used by the patients as well as changes in the chromatographic mobility of 51 Cr-EDTA, demonstrated after incubation with gastric juice

  19. [51Cr]EDTA intestinal permeability in children with cow's milk intolerance

    International Nuclear Information System (INIS)

    Schrander, J.J.; Unsalan-Hooyen, R.W.; Forget, P.P.; Jansen, J.

    1990-01-01

    Making use of [ 51 Cr]EDTA as a permeability marker, we measured intestinal permeability in a group of 20 children with proven cow's milk intolerance (CMI), a group of 17 children with similar complaints where CMI was excluded (sick controls), and a group of 12 control children. [ 51 Cr]EDTA test results (mean +/- SD) were 6.85 +/- 3.64%, 3.42 +/- 0.94%, and 2.61 +/- 0.67% in the group with CMI, the sick control, and the control group, respectively. When compared to both control groups, patients with cow's milk intolerance (CMI) showed a significantly increased small bowel permeability. We conclude that the [ 51 Cr]EDTA test can be helpful for the diagnosis of cow's milk intolerance

  20. (51Cr)EDTA intestinal permeability in children with cow's milk intolerance

    Energy Technology Data Exchange (ETDEWEB)

    Schrander, J.J.; Unsalan-Hooyen, R.W.; Forget, P.P.; Jansen, J. (Academic Hospital Maastricht (Netherlands))

    1990-02-01

    Making use of ({sup 51}Cr)EDTA as a permeability marker, we measured intestinal permeability in a group of 20 children with proven cow's milk intolerance (CMI), a group of 17 children with similar complaints where CMI was excluded (sick controls), and a group of 12 control children. ({sup 51}Cr)EDTA test results (mean +/- SD) were 6.85 +/- 3.64%, 3.42 +/- 0.94%, and 2.61 +/- 0.67% in the group with CMI, the sick control, and the control group, respectively. When compared to both control groups, patients with cow's milk intolerance (CMI) showed a significantly increased small bowel permeability. We conclude that the ({sup 51}Cr)EDTA test can be helpful for the diagnosis of cow's milk intolerance.

  1. Intestinal permeability to [51Cr]EDTA in children with Crohn's disease and celiac disease

    International Nuclear Information System (INIS)

    Turck, D.; Ythier, H.; Maquet, E.; Deveaux, M.; Marchandise, X.; Farriaux, J.P.; Fontaine, G.

    1987-01-01

    [ 51 Cr]EDTA was used as a probe molecule to assess intestinal permeability in 7 healthy control adults, 11 control children, 17 children with Crohn's disease, and 6 children with untreated celiac disease. After subjects fasted overnight, 75 kBq/kg (= 2 microCi/kg) 51 Cr-labeled EDTA was given by mouth; 24-h urinary excretion of [ 51 Cr]EDTA was measured and expressed as a percentage of the total oral dose. Mean and SD were as follows: control adults 1.47 +/- 0.62, control children 1.59 +/- 0.55, and patients with Crohn's disease or celiac disease 5.35 +/- 1.94. The difference between control children and patients was statistically significant (p less than 0.001). These results show that intestinal permeability to [ 51 Cr]EDTA is increased among children with active or inactive Crohn's disease affecting small bowel only or small bowel and colon, and with untreated celiac disease. The [ 51 Cr]EDTA permeability test could facilitate the decision to perform more extensive investigations in children suspected of small bowel disease who have atypical or poor clinical and biological symptomatology

  2. Intestinal permeability to [51Cr]EDTA in children with cystic fibrosis

    International Nuclear Information System (INIS)

    Leclercq-Foucart, J.; Forget, P.; Sodoyez-Goffaux, F.; Zappitelli, A.

    1986-01-01

    Intestinal permeability was investigated in 14 children with cystic fibrosis making use of [ 51 Cr]EDTA as probe molecule. Ten normal young adults and 11 children served as controls. After oral administration of [ 51 Cr]EDTA, 24 h urine was collected. Urinary radioactivity was calculated and results expressed as percentage of oral dose excreted in 24 h urine. Mean and SEM were as follows: 2.51 +/- 0.21, 2.35 +/- 0.24, and 13.19 +/- 1.72 for control children, normal adults, and cystic fibrosis patients, respectively. The permeability differences between cystic fibrosis patients and either control children or control adults are significant (p less than 0.001)

  3. Small bowel permeability to 51Cr-EDTA in children with recurrent abdominal pain

    International Nuclear Information System (INIS)

    Meer, S.B. van der.; Forget, P.P.

    1990-01-01

    Small bowel permeability was investigated in 87 children with recurrent abdominal pain by measuring the 24-h urinary excretion of orally administered 51 Cr-EDTA. The mean excreation was 3.64% ± 1.49% per 24 h. The difference between the mean urinary excretion in children with recurrent abdominal pain and control children (2.51% ± 0.70%), was significant (p<0.01, two sample t-test). The increased small permeability in children with recurrent abdominal pain might indicate an intestinal etiology for the patients complaints

  4. Reversibility of increased intestinal permeability to 51Cr-EDTA in patients with gastrointestinal inflammatory diseases

    International Nuclear Information System (INIS)

    Jenkins, R.T.; Jones, D.B.; Goodacre, R.L.; Collins, S.M.; Coates, G.; Hunt, R.H.; Bienenstock, J.

    1987-01-01

    Intestinal permeability in adults with inflammatory gastrointestinal diseases was investigated by measuring the 24-h urinary excretion of orally administered 51 Cr-EDTA. Eighty controls along with 100 patients with Crohn's disease, 46 patients with ulcerative colitis, 20 patients with gluten-sensitive enteropathy, and 18 patients with other diseases were studied. In controls, the median 24-h excretion was 1.34%/24 h of the oral dose. Patients with Crohn's disease (median 2.96%/24 h), ulcerative colitis (median 2.12%/24 h), and untreated gluten-sensitive enteropathy (median 3.56%/24 h) had significantly elevated urinary excretion of the probe compared to controls (p less than 0.0001). Increased 24-h urinary excretion of 51 Cr-EDTA had a high association with intestinal inflammation (p less than 0.0001). Test specificity and sensitivity were 96% and 57%, respectively. A positive test has a 96% probability of correctly diagnosing the presence of intestinal inflammation, whereas a negative test has a 50% probability of predicting the absence of disease

  5. Relationship between intestinal permeability to [51Cr]EDTA and inflammatory activity in asymptomatic patients with Crohn's disease

    International Nuclear Information System (INIS)

    Pironi, L.; Miglioli, M.; Ruggeri, E.; Levorato, M.; Dallasta, M.A.; Corbelli, C.; Nibali, M.G.; Barbara, L.

    1990-01-01

    The relationship between intestinal permeability to an oral dose (100 mu Ci) of [51CR]EDTA and the inflammatory activity of Crohn's disease was studied in 63 adult patients (32 unresected and 31 resected) who underwent 162 evaluations. The results of the [51CR]EDTA test were compared with the serum levels of the acute-phase reactant proteins (APRP) and with the result of the [111In]leukocyte scanning, respectively, as an indirect and direct method to assess intestinal inflammation. In a group of healthy adult controls, the upper normal value for the 24-hr urinary [51CR]EDTA excretion was 3.61 (97.5% percentile) and the mean coefficient of variation was 21%. Sensitivity and specificity of the [51CR]EDTA test in identifying active inflammation expressed by increased serum levels of APRP were, respectively, 97% and 54% in the unresected group and 68% and 52% in the resected group of patients. The low specificity of the test was due to the presence of increased [51CR]EDTA urinary excretion in about half the cases with normal serum levels of APRP. The [111In]leukocyte scanning was performed in a subgroup of 11 patients (three unresected and eight resected) with normal serum levels of APRP, six with increased and five with normal [51CR]EDTA urinary excretion. All six patients with increased intestinal permeability had a positive 111In image of mild to moderate degree of activity. A positive 111In scan was present in two of the five patients with normal permeability; these were two resected patients

  6. Intestinal permeability to (/sup 51/Cr)EDTA in children with Crohn's disease and celiac disease

    Energy Technology Data Exchange (ETDEWEB)

    Turck, D.; Ythier, H.; Maquet, E.; Deveaux, M.; Marchandise, X.; Farriaux, J.P.; Fontaine, G.

    1987-07-01

    (/sup 51/Cr)EDTA was used as a probe molecule to assess intestinal permeability in 7 healthy control adults, 11 control children, 17 children with Crohn's disease, and 6 children with untreated celiac disease. After subjects fasted overnight, 75 kBq/kg (= 2 microCi/kg) /sup 51/Cr-labeled EDTA was given by mouth; 24-h urinary excretion of (/sup 51/Cr)EDTA was measured and expressed as a percentage of the total oral dose. Mean and SD were as follows: control adults 1.47 +/- 0.62, control children 1.59 +/- 0.55, and patients with Crohn's disease or celiac disease 5.35 +/- 1.94. The difference between control children and patients was statistically significant (p less than 0.001). These results show that intestinal permeability to (/sup 51/Cr)EDTA is increased among children with active or inactive Crohn's disease affecting small bowel only or small bowel and colon, and with untreated celiac disease. The (/sup 51/Cr)EDTA permeability test could facilitate the decision to perform more extensive investigations in children suspected of small bowel disease who have atypical or poor clinical and biological symptomatology.

  7. Permeability of the small intestine to [51Cr]EDTA in children with acute gastroenteritis or eczema

    International Nuclear Information System (INIS)

    Forget, P.; Sodoyez-Goffaux, F.; Zappitelli, A.

    1985-01-01

    Increased gut permeability to macromolecules is thought to be an important factor in the development of food hypersensitivity. The latter can develop in the course of acute gastroenteritis and could play a role in infantile eczema. The authors studied gut permeability in 10 normal adults, 11 control children, 7 children with acute gastroenteritis, and 8 patients with infantile eczema, making use of [ 51 Cr]EDTA as probe molecule. [ 51 Cr]EDTA was given orally (50-100 microCi); 24-h urinary excretion of [ 51 Cr]EDTA was measured and expressed as a percentage of the oral dose. Mean and standard error were 2.35 +/- 0.24, 2.51 +/- 0.21, 9.96 +/- 3.44, and 10.90 +/- 2.05 in normal adults, control children, and gastroenteritis and eczema patients, respectively. Differences between controls and either gastroenteritis (p less than 0.001) or eczema (p less than 0.001) patients are significant. The results support the hypothesis that increased gut permeability could play a role in food hypersensitivity

  8. /sup 51/Cr-EDTA//sup 14/C-mannitol intestinal permeability test. Clinical use in screening for coeliac disease

    Energy Technology Data Exchange (ETDEWEB)

    Fotherby, K.J.; Wraight, E.P.; Neale, G.

    1988-01-01

    An intestinal permeability test with a combination of /sup 51/Cr-EDTA and /sup 14/C-mannitol was performed under routine conditions on 176 occasions in 161 adult patients. Of these patients, 116 were under investigation for possible coeliac disease, 33 were known to have coeliac disease, and 12 had inflammatory bowel disease. Small-bowel biopsies were performed in 61 patients. Expressing the results as the ratio of the 6-h urinary recoveries of the two probes was as sensitive as 95%, but more specific for histological mucosal abnormality (62% versus 46%) than measuring the urinary recovery of /sup 51/Cr-EDTA alone. All but two of the patients with active inflammatory bowel disease, whether Crohn's disease or ulcerative colitis, had an abnormal ratio. The /sup 51/Cr-EDTA//sup 14/C-mannitol intestinal permeablity test with a 6-h urine collection is a rapid and simple test of small-intestinal function suitable for routine use. 19 refs.

  9. Excretion of radionuclides in human breast milk following administration of 125I-fibrinogen, 99Tc/sup m/-MAA and 51Cr-EDTA

    International Nuclear Information System (INIS)

    Mattsson, S.; Johansson, L.; Nosslin, B.; Ahlgren, L.

    1981-01-01

    Very few biokinetic and dosimetric data for estimating the absorbed dose to a breast-feeding child are available in the literature. The few available are usually case reports. We have measured the activity concentration in breast milk from one patient after administration of 125 I-fibrinogen, from two patients after administration of 99 Tc/sup m/-macroaggregated albumin, and from one patient after administration of 51 Cr-EDTA. We have compared our data with earlier published results and estimated the absorbed dose to the breast-feeding child using biokinetic data presented in this work and recently published S-values for new-born children

  10. Rapid decline in 51Cr-EDTA measured renal function during the first weeks following lung transplantation

    DEFF Research Database (Denmark)

    Hornum, M.; Iversen, M.; Steffensen, I.

    2009-01-01

    We previously described a 54% decline in renal function at 6 months after lung transplantation (LTx). We hypothesized that this decline is a very early event following LTx. Thirty-one consecutive patients (16 females/15 males), mean age 49 (+/-13) years, with emphysema, cystic fibrosis/bronchiect......We previously described a 54% decline in renal function at 6 months after lung transplantation (LTx). We hypothesized that this decline is a very early event following LTx. Thirty-one consecutive patients (16 females/15 males), mean age 49 (+/-13) years, with emphysema, cystic fibrosis....../bronchiectasis or idiopathic pulmonary fibrosis were included in an analysis of renal function before and after LTx. The glomerular filtration rate (GFR) was measured using the (51)Cr-ethylenediaminetetra acetic acid plasma clearance single injection technique (mGFR) at baseline before transplantation and at 1, 2, 3 and 12...

  11. Chromium-51-EDTA clearance in adults with a single-plasma sample.

    Science.gov (United States)

    Mårtensson, J; Groth, S; Rehling, M; Gref, M

    1998-12-01

    In 1996, a committee on renal clearance recommended a mean sojourn time-based methodology for single-sample determination of plasma clearance of 99mTc-diethylenetriamine pentaacetic acid (DTPA) to be used on adults if the patient's glomerular filtration rate (GFR) is suspected to be >30 ml/min. The main purpose of this study was to derive a mean sojourn time-based formula for calculation of 51Cr-ethylenediamine tetraacetic acid (EDTA) clearance in adults. Two groups of patients with 51Cr-EDTA clearance (Cl) between 16 and 172 ml/min were studied. In Group I (n = 46), reference Cl was determined as a multiplasma sample, single-injection method (ClSM). Sixteen blood samples were drawn from 0 until 5 hr after a single intravenous injection of 51Cr-EDTA. In Group II (n = 1046), reference Cl was determined by the Brøchner-Mortensen four-sample clearance method (ClBM). The plasma time-activity curves of Group I were used to derive two mean sojourn time-based formulas (Formulas 1 and 2) for calculation of a single-sample clearance. Formula 1 was derived from the entire time-activity curve, whereas the derivation of Formula 2 used only the final slope of the time-activity curve. The accuracy of the two formulas and the Christensen and Groth 99mTc-DTPA formula was tested on Group II. Chromium-51-EDTA Cl calculated by Formula 1 was almost identical to the Cl calculated by the reference Cl method (r = 0.982; SDdiff = 5.82 ml/min). Both 51Cr-EDTA Cl calculated by Formula 2 and by the 99mTc-DTPA formula showed close correlation with the reference method (r = 0.976, r = 0.985, respectively) but systematically overestimated GFR for the whole range of clearance values by 3.5 and 3.2 ml/min (ptime methodology. The determination is marginally more accurate (ptime-activity curve than from only the final slope. The single-sample formula derived for determination of 99mTc-DTPA Cl tends slightly to overestimate GFR if used to calculate 51Cr-EDTA Cl.

  12. Respiratory clearance of aerosolized radioactive solutes of varying molecular weight

    International Nuclear Information System (INIS)

    Huchon, G.J.; Montgomery, A.B.; Lipavsky, A.; Hoeffel, J.M.; Murray, J.F.

    1987-01-01

    To determine the influence of varying molecular weight (mol wt) on respiratory clearance of aerosolized solutes, we studied eight radiopharmaceuticals, each administered to four dogs: sodium /sup 99m/Tc pertechnetate (TcO4), /sup 99m/Tc glucoheptonate ([/sup 99m/Tc]GH), 51Cr-ethylenedinitrotetraacetate ([51Cr]EDTA), /sup 99m/Tc diethylenetriaminepentaacetate ([99mTc] DTPA), 111 In diethylenetriaminepentaacetate ([ 111 In]DTPA), 67 Ga desferoxaminemesylate ([ 67 Ga]DFOM), /sup 99m/Tc dextran ([/sup 99m/Tc]DX) and 111 In transferrin ([ 111 In]TF). After aerosolization (0.8 m MMD, 2.4 GSD), clearance was determined for 30 min and then corrected by intravenous injection for nonairspace radioactivity. In-TF clearance (0.11 +/- 0.10%/min) was lower than TcO4 (6.32 +/- 0.62%/min), [/sup 99m/Tc]GH (1.50 +/- 0.37%/min), [ 51 Cr]EDTA (2.38 +/- 1.02%/min), [/sup 99m/Tc]DTPA (3.51 +/- 0.40%/min), [ 111 In]DTPA (2.35 +/- 0.42%/min), [ 67 Ga] DFOM (1.99 +/- 0.49%/min) and [/sup 99m/Tc]DX (1.81 +/- 0.75%/min) clearances (p less than 0.001). TcO4 clearance was higher than others (p less than 0.001). Technetium binding to DX was unsatisfactory; aerosolization caused unbinding from DTPA. We conclude that respiratory clearance of large mol wt solutes within 30 min is negligible and, that clearance of molecules between 347-5099 daltons differs greatly, suggesting that binding and/or intrapulmonary retention affect transfer

  13. The clearance concept with special reference to determination of glomerular filtration rate in patients with fluid retention

    DEFF Research Database (Denmark)

    Henriksen, Ulrik L; Henriksen, Jens H

    2014-01-01

    In subjects without fluid retention, the total plasma clearance of a renal filtration indicator (inulin, (99m) Tc-DTPA, (51) Cr-EDTA) is close to the urinary plasma clearance. Conversely, in patients with fluid retention (oedema, pleural effusions, ascites), there is a substantial discrepancy...

  14. Estimation of normal chromium-51 ethylene diamine tetra-acetic acid clearance in children

    International Nuclear Information System (INIS)

    Piepsz, A.; Pintelon, H.; Ham, H.R.

    1994-01-01

    In order to estimate the normal range of chromium-51 ethylene diamine tetra-acetic acid (EDTA) clearance in children, we selected a series of 256 patients with past or present urinary tract infection who showed, at the time of the clearance determination, normal technetium-99m dimercaptosuccinic acid (DMSA) scintigraphy and normal left to right DMSA relative uptake. The clearance was calculated by means of either the simplified second exponential method or the 120-min single blood sample; Chantler's correction was used in order to correct for having neglected the first exponential. There was a progressive increase in clearance from the first weeks of life (mean value around 1 month: 55 ml/min/1.73 m 2 ), with a plateau at around 18 months. Between 2 and 17 years of age, the clearance values remained constant, with a mean value of 114 ml/min/1.73 m 2 (SD: 24 ml/min); this is similar to the level described for inulin clearance. No significant differences were observed between boys and girls, or between clearance values calculated with one or with two blood samples. Taking into account the hour of intravenous injection of the tracer, we did not observe any influence of the lunchtime meal on the distribution of the 51 Cr-EDTA clearance values. (orig.)

  15. Renal clearance of /sup 99m/Tc-methylene-diphosphonate in human beings

    Energy Technology Data Exchange (ETDEWEB)

    Vattimo, A.

    1987-12-01

    The renal clearance of /sup 99m/Tc-MDP was measured in 13 patients who had bone scans and compared with the renal clearance of /sup 51/Cr-EDTA. No difference was found between the renal clearance of the two tracers, showing a close correlation (r = 0.98). These data suggest that the /sup 99m/Tc-MDP is excreted by the kidneys by glomerular filtration without tubular secretion.

  16. Renal clearance of 99mTc-methylene-diphosphonate in human beings

    International Nuclear Information System (INIS)

    Vattimo, A.

    1987-01-01

    The renal clearance of 99m Tc-MDP was measured in 13 patients who had bone scans and compared with the renal clearance of 51 Cr-EDTA. No difference was found between the renal clearance of the two tracers, showing a close correlation (r = 0.98). These data suggest that the 99m Tc-MDP is excreted by the kidneys by glomerular filtration without tubular secretion. (orig.) [de

  17. Reassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part I: Analytically correct relationship between total and one-pool clearance

    DEFF Research Database (Denmark)

    Jødal, Lars; Brøchner-Mortensen, Jens

    2009-01-01

    were within ±8 % for adults and ±13 % for children (95 % limits of agreement). Conclusions. The true relationship between Cl and Cl1 of 51Cr-EDTA is given, resulting in a common correction equation applicable for children and adults. The new equation has better mathematical behaviour than quadratic......, a (minutes), not used for determination of Cl1, were measured. Results. The true relationship between Cl and Cl1 is given by Cl = Cl1/(1+f·Cl1), where f = a/PV. For men, women and children alike, the equation f = 0.0032·BSA-1.3 was applicable (BSA = body surface area in m²). Estimation errors on clearance...... equations on very high values of clearance and takes into account dependence on body size....

  18. Whole-body microvascular permeability of small molecules in man: clinical aspects, basic concepts and limitations of the single injection technique

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl

    1985-01-01

    In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured by the indica......In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured...

  19. Measurement of capillary permeability in canine heart determined by the tissue injection, residue detection method

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Paaske, W P; Haunsø, S

    1991-01-01

    (apparent) interstitial volume of distribution, tev is the mean transit time of the indicator, and klo is the recorded fractional initial washout rate constant. In experiments on open chest dog hearts we examined capillary permeability for 51Cr-EDTA and 99mTc-DTPA with the tissue injection, residue...

  20. Stability, protein binding and clearance studies of [99mTc]DTPA. Evaluation of a commercially available dry-kit

    DEFF Research Database (Denmark)

    Rehling, M

    1988-01-01

    [99mTc]DTPA has achieved widespread use for the measurement of glomerular filtration rate (GFR) with the single injection plasma clearance technique and for gamma-camera renography. However, the quality of the commercial preparations varies. The purpose of the present investigation was to study...... the quality of a commercial [99mTc]DTPA preparation (C.I.S., France) with reference to stability, protein binding and accuracy of the determined plasma clearance values as a measure of GFR. The stability of the preparations was studied by thin-layer chromatography, the in vitro protein binding by Sephadex.......7% and 1.1%, respectively. The plasma clearance of [99mTc]DTPA was on an average 3.7% higher than that of [51Cr]EDTA in 27 patients. It is concluded that the [99mTc]DTPA preparation is reliable for the measurement of GFR. The preparation is stable for at least six hours at room temperature...

  1. Kidney function measured by clearance. Methods and indications. An update; Zur Messung der Nierenfunktion durch Clearancebestimmungen. Methoden und Indikationen. Ein Update

    Energy Technology Data Exchange (ETDEWEB)

    Durand, E. [Universitaetskrankenhaus Bicetre, Paris (France); Mueller-Suur, R. [Karolinska Inst., Danderyds Krankenhaus und Aleris Fysiologlab, Stockholm (Sweden)

    2010-09-15

    Renal function impairment can be monitored by many tests. Measurement of plasma-creatinine level is the most used method, 24 h plasma-creatininclearance with urine collection is used by others and also other alternative but indirect methods exist. However, the use of radionuclide-clearances is by far the easiest performed method with the highest accuracy and precision and gives very low irradiation dose. In the following we will discuss the different radiopharmaceuticals in use, their plus and minus, the different clearance methods in use, their limitations and give some clinically important indications to perform clearance investigations according to consensus reports. Summarizing the use of plasma clearance of 51-Cr-EDTA after a single injection with one blood sample can be generally recommended, however with some modifications in special clinical situations, which are pointed out. Please note, that this paper is, for a significant part, an update of a previous paper published 2003 in ''Der Nuklearmediziner'' (orig.)

  2. Assessing glomerular filtration rate (GFR) in critically ill patients with acute kidney injury - true GFR versus urinary creatinine clearance and estimating equations

    Science.gov (United States)

    2013-01-01

    Introduction Estimation of kidney function in critically ill patients with acute kidney injury (AKI), is important for appropriate dosing of drugs and adjustment of therapeutic strategies, but challenging due to fluctuations in kidney function, creatinine metabolism and fluid balance. Data on the agreement between estimating and gold standard methods to assess glomerular filtration rate (GFR) in early AKI are lacking. We evaluated the agreement of urinary creatinine clearance (CrCl) and three commonly used estimating equations, the Cockcroft Gault (CG), the Modification of Diet in Renal Disease (MDRD) and the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations, in comparison to GFR measured by the infusion clearance of chromium-ethylenediaminetetraacetic acid (51Cr-EDTA), in critically ill patients with early AKI after complicated cardiac surgery. Methods Thirty patients with early AKI were studied in the intensive care unit, 2 to 12 days after complicated cardiac surgery. The infusion clearance for 51Cr-EDTA obtained as a measure of GFR (GFR51Cr-EDTA) was calculated from the formula: GFR (mL/min/1.73m2) = (51Cr-EDTA infusion rate × 1.73)/(arterial 51Cr-EDTA × body surface area) and compared with the urinary CrCl and the estimated GFR (eGFR) from the three estimating equations. Urine was collected in two 30-minute periods to measure urine flow and urine creatinine. Urinary CrCl was calculated from the formula: CrCl (mL/min/1.73m2) = (urine volume × urine creatinine × 1.73)/(serum creatinine × 30 min × body surface area). Results The within-group error was lower for GFR51Cr-EDTA than the urinary CrCl method, 7.2% versus 55.0%. The between-method bias was 2.6, 11.6, 11.1 and 7.39 ml/min for eGFRCrCl, eGFRMDRD, eGFRCKD-EPI and eGFRCG, respectively, when compared to GFR51Cr-EDTA. The error was 103%, 68.7%, 67.7% and 68.0% for eGFRCrCl, eGFRMDRD, eGFRCKD-EPI and eGFRCG, respectively, when compared to GFR51Cr-EDTA. Conclusions The study

  3. Contrast media and glomerular filtration: dose dependence of clearance for three agents

    International Nuclear Information System (INIS)

    Baeck, S.E.K.; Krutzen, E.; Nilsson-Ehle, P.

    1988-01-01

    Determination of plasma clearance of contrast agents has been advocated as a means to assess glomerular filtration rate. To evaluate the feasibility of different agents for this purpose, we have compared, in healthy volunteers, the dose dependence of plasma clearance for three contrast media (iohexol, a nonionic agent, and iothalamate and metrizoate, which are ionic substances), with special emphasis on the lower dose range (2-20 mL corresponding to 0.9-12.9 g, depending on dose and agent). Iohexol and iothalamate were cleared at constant rates, irrespective of given dose, whereas metrizoate clearance increased significantly at lower doses. In general, the clearances or iothalamate and metrizoate were, respectively, moderately and markedly higher than that of iohexol. The clearance of different doses of metrizoate (2 mL versus a radiographic dose of 40 mL or more) was also compared with the clearance of [ 51 Cr]EDTA in two groups of patients with reduced renal function. When compared with [ 51 Cr]EDTA in patients with renal dysfunction, metrizoate was cleared significantly faster after a 2-mL dose, whereas clearances were identical when the metrizoate dose was 40 mL or more. These findings indicate that tubular secretion plays an active role in the elimination of metrizoate. The pharmacokinetic properties of iohexol, in combination with its low toxicity, make it a suitable agent for determination of glomerular filtration rate in clinical practice

  4. Estimation of chromium-51 ethylene diamine tetra-acetic acid plasma clearance: A comparative assessment of simplified techniques

    International Nuclear Information System (INIS)

    Picciotto, G.; Cacace, G.; Mosso, R.; De Filippi, P.G.; Cesana, P.; Ropolo, R.

    1992-01-01

    Chromium-51 ethylene diamine tetra-acetic acid ( 51 Cr-EDTA) total plasma clearance was evaluated using a multi-sample method (i.e. 12 blood samples) as the reference compared with several simplified methods which necessitated only one or few blood samples. The following 5 methods were evaluated: Terminal slope-intercept method with 3 blood samples, simplified method of Broechner-Mortensen and 3 single-sample methods (Constable, Christensen and Groth, Tauxe). Linear regression analysis was performed. Standard error of estimate, bias and imprecision of different methods were evaluated. For 51 Cr-EDTA total plasma clearance greater than 30 ml.min -1 , the results which most approximated the reference source were obtained by the Christensen and Groth method at a sampling time of 300 min (inaccuracy of 4.9%). For clearances between 10 and 30 ml.min -1 , single-sample methods failed to give reliable results. Terminal slope-intercept and Broechner-Mortensen methods were better, with inaccuracies of 17.7% and 16.9%, respectively. Although sampling times at 180, 240 and 300 min are time-consuming for patients, 51 Cr-EDTA total plasma clearance can be accurately calculated for values greater than 10 ml.min -1 using the Broechner-Mortensen method. In patients with clearance greater than 30 ml.min -1 , single-sample techniques provide a good alternative to the multi-sample method; the choice of the method to be used depends on the degree of accuracy required. (orig.)

  5. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...

  6. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....

  7. Clearance Kinetics and Clearance Routes of Molecules From the Suprachoroidal Space After Microneedle Injection.

    Science.gov (United States)

    Chiang, Bryce; Wang, Ke; Ethier, C Ross; Prausnitz, Mark R

    2017-01-01

    To determine clearance kinetics and routes of clearance of molecules from the suprachoroidal space (SCS) of live New Zealand White rabbits. Suprachoroidal space collapse rate and pressure changes after microneedle injection into SCS were determined. Fluorescent fundus images were acquired to determine clearance rates of molecules ranging in size from 332 Da to 2 MDa. Microneedle injections of fluorescein were performed, and samples were taken from various sites over time to determine amount of fluorescein exiting the eye. Clearance transport was modeled theoretically and compared with experimental data. After injection, pressures in SCS and vitreous humor spiked and returned to baseline within 20 minutes; there was no difference between these two pressures. Suprachoroidal space collapse occurred within 40 minutes. One hour after fluorescein injection, 46% of fluorescein was still present in the eye, 15% had transported across sclera, 6% had been cleared by choroidal vasculature, and 4% had exited via leakage pathways. Characteristic clearance time increased in proportion with molecular radius, but total clearance of 2 MDa FITC-dextran was significantly slower (21 days) than smaller molecules. These data generally agreed with predictions from a theoretical model of molecular transport. Guided by experimental data in the context of model predictions, molecular clearance from SCS occurred in three regimes: (1) on a time scale of approximately 10 minutes, fluid and molecules exited SCS by diffusion into sclera and choroid, and by pressure-driven reflux via transscleral leakage sites; (2) in approximately 1 hour, molecules cleared from choroid by blood flow; and (3) in 1 to 10 hours, molecules cleared from sclera by diffusion and convection.

  8. Optimal sampling strategies to assess inulin clearance in children by the inulin single-injection method

    NARCIS (Netherlands)

    van Rossum, Lyonne K.; Mathot, Ron A. A.; Cransberg, Karlien; Vulto, Arnold G.

    2003-01-01

    Glomerular filtration rate in patients can be determined by estimating the plasma clearance of inulin with the single-injection method. In this method, a single bolus injection of inulin is administered and several blood samples are collected. For practical and convenient application of this method

  9. Renal function measured by X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Boijsen, M.; Jacobsson, L.; Tylen, U.; Sahlgrenska Sjukhuset, Goeteborg

    1987-01-01

    In twenty-six patients injected with metrizoate during urography, plasma was analyzed for iodine concentration using X-ray fluorescence analysis, and total plasma clearance of contrast medium was calculated. Total plasma clearance of 51 Cr-EDTA was also determined, but not simultaneously, in order to find out if the urographic procedure would influence the kidneys to such an extent that the contrast medium clearance value would differ much from the 51 Cr-EDTA clearance value. The errors in the method were assessed and the total error of the contrast medium clearance determination was calculated. When comparing 51 Cr-EDTA and metrizoate clearance a correlation of 0.94 and a mean ratio of 1.046 (SD 0.138) was found. The assessable errors cannot fully explain the standard deviation, which might indicate a transient change in kidney function related to elements of the urographic procedure such as laxation with possible dehydration and/or the contrast medium dose. (orig.)

  10. The effect of metabolic regulation on microvascular permeability to small and large molecules in short-term juvenile diabetics

    DEFF Research Database (Denmark)

    Parving, H H; Noer, Ivan; Deckert, Toke

    1976-01-01

    injected 125I-labelled human serum albumin; GFR was measured on the forearm by straingauge plethysmography and CDS for 51Cr-EDTA clearance; CFC was measured on the forearm by straingauge plethysmography and CDC, for 51Cr-EDTA was determined in the jyperaemic anterio tibial muscle by the local clearance......The microvascular permeability to small and large molecules was studied during good and poor metabolic regulation in ten short duration juvenile diabetics. The following variables were measured; daily urinary albumin and beta2-microglobulin-excretion rates, whole body transcapillary escape rate...... of albumin (TER), glomerular filtration rate (GFR), capillary filtration coefficient (CFC), and capillary diffusion capacity (CDC). The urinary albumin and beta2-microglobulin concentration were measured by sensitive radioimmunoassays; TER was detemined from the initial disappearance of intravenously...

  11. Ocular silicon distribution and clearance following intravitreal injection of porous silicon microparticles.

    Science.gov (United States)

    Nieto, Alejandra; Hou, Huiyuan; Sailor, Michael J; Freeman, William R; Cheng, Lingyun

    2013-11-01

    Porous silicon (pSi) microparticles have been investigated for intravitreal drug delivery and demonstrated good biocompatibility. With the appropriate surface chemistry, pSi can reside in vitreous for months or longer. However, ocular distribution and clearance pathway of its degradation product, silicic acid, are not well understood. In the current study, rabbit ocular tissue was collected at different time point following fresh pSi (day 1, 5, 9, 16, and 21) or oxidized pSi (day 3, 7, 14, 21, and 35) intravitreal injection. In addition, dual-probe simultaneous microdialysis of aqueous and vitreous humor was performed following a bolus intravitreal injection of 0.25 mL silicic acid (150 μg/mL) and six consecutive microdialysates were collected every 20 min. Silicon was quantified from the samples using inductively coupled plasma-optical emission spectroscopy. The study showed that following the intravitreal injection of oxidized pSi, free silicon was consistently higher in the aqueous than in the retina (8.1 ± 6.5 vs. 3.4 ± 3.9 μg/mL, p = 0.0031). The area under the concentration-time curve (AUC) of the retina was only about 24% that of the aqueous. The mean residence time was 16 days for aqueous, 13 days for vitreous, 6 days for retina, and 18 days for plasma. Similarly, following intravitreal fresh pSi, free silicon was also found higher in aqueous than in retina (7 ± 4.7 vs. 3.4 ± 4.1 μg/mL, p = 0.014). The AUC for the retina was about 50% of the AUC for the aqueous. The microdialysis revealed the terminal half-life of free silicon in the aqueous was 30 min and 92 min in the vitreous; the AUC for aqueous accounted for 38% of the AUC for vitreous. Our studies indicate that aqueous humor is a significant pathway for silicon egress from the eye following intravitreal injection of pSi crystals. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Single-tracer technique to evaluate pulmonary edema and its application to detect the effect of hexamethylene diisocyanate trimer aerosol exposures

    International Nuclear Information System (INIS)

    Valentini, J.E.; Wong, K.L.; Alarie, Y.

    1983-01-01

    Two hours after a four-hour exposure to hexamethylene diisocyanate trimer (HDIt) aerosol between 2.5 and 39 mg/m3, mice were injected iv with 51 Cr-EDTA (chromium ethylenediaminetetraacetate). Ten minutes later the lung was lavaged. A larger amount of 51 Cr-EDTA was detected in the lung lavage of HDIt mice than of controls in a concentration-related fashion. The concentration-response curve was shifted to the left compared with that constructed using lung weight increase as response. Kinetic studies of the plasma level of 51 Cr-EDTA revealed a three-exponential profile in normal mice, and similar plasma levels were obtained with mice exposed to 18-24 mg/m3 HDIt. However, both the amount of 51 Cr-EDTA in the alveolar space and concentration in the pulmonary extravascular compartment were higher in HDIt-exposed mice than in controls. The data of 51 Cr-EDTA distribution in the lung were fitted with a three-compartment model. According to the model, HDIt exposures increase the permeability constants of 51 Cr-EDTA transport into the alveolar space from blood which accounts for the larger amount of 51 Cr-EDTA in lung lavage of HDIt-exposed mice. This 51 Cr-EDTA injection and lung lavage technique is a sensitive method for detecting pulmonary edema

  13. Influence of renal function on the elimination of morphine and morphine glucuronides

    DEFF Research Database (Denmark)

    Wolff, Jesper; Bigler, Dennis Richard; Christensen, C B

    1988-01-01

    plasma. No significant correlation was found between total body clearance of unconjugated morphine and 51Cr-EDTA clearance. However, patients with renal insufficiency had impaired elimination of morphine glucuronides, and the apparent clearance was significantly correlated with the 51Cr-EDTA clearance (r...... = 0.94, p less than 0.001). A relatively long terminal elimination of half-life of morphine was found in all patients (mean +/- SD: 9.2 +/- 2.5 h), irrespective of glomerular function....

  14. Evaluation of total renal function from 99mTc-MAG3 scintigraphy in children

    International Nuclear Information System (INIS)

    Andersson, L.G.; Bratteby, L.E.; Takalo, R.; Svensson, L.

    2002-01-01

    Aim: The aim of the present study was to evaluate the usefulness of dynamic scintigraphy in the assessment of total renal function in children. The Patlak slope of 99m Tc-MAG3 renography curves were compared to the plasma clearance values of 51Cr-EDTA. Material and methods: The study sample consisted of 53 boys and 33 girls with various nephrologic disorders, referred for routine clinical reasons. The median age of the subjects was 5.1 years (range 0.3 - 14.1 years). Imaging procedure. In supine position, the patient received a bolus injection of 1 MBq/kg, (minimum 10 MBq) 99m Tc-MAG3 and a posterior dynamic gamma camera registration was performed for 21 min using 1 frame per second during the first minute and thereafter 10 seconds frames. Data analysis. Time-activity curves were generated from manually drawn heart and renal regions of interest. The MAG3 uptake was calculated from the Patlak-Rutland plot of each kidney by linear curve fitting until the beginning of the excretory phase. A sum of the slope values was used as a measure of total renal MAG3 uptake. Cr-EDTA clearance. Glomerular filtration rate (GFR) was measured from the plasma clearance of 51 Cr-EDTA using single injection, multiple-sample technique. After intravenous injection of 51 Cr-EDTA (74 kBq/kg for children up to 7 years, 37 kBq/kg for children older than 7 years), blood samples were drawn at 5, 10, 15, 45, 60, 120 and 180 min for radioactivity measurement. The GFR was calculated according to Broechner-Mortensen and expressed in ml/min. Results: The absolute 51 Cr-EDTA clearance varied from 9 to 143 ml/min. There was a close linear relationship between 51 Cr-EDTA clearance and MAG3 uptake (Fig). The correlation coefficient was 0.90 and the regression equation (y=43.5 x + 664). Conclusions: In the present study, there was a good correlation between plasma clearance of 51 Cr-EDTA and the sum of the Patlak slopes. The regression equation can be utilised to transform the 99m Tc-MAG3 uptake to an

  15. Revisiting normal {sup 51}Cr-ethylenediaminetetraacetic acid clearance values in children

    Energy Technology Data Exchange (ETDEWEB)

    Piepsz, A.; Tondeur, M. [Department of Radioisotopes, CHU St Pierre, Brussels (Belgium); Ham, H. [Department of Nuclear Medicine, UZ Ghent, Ghent (Belgium)

    2006-12-15

    Normal {sup 51}Cr-ethylenediaminetetraacetic acid (EDTA) clearance values as a function of age were published a number of years ago. These values were based on data from children with a normal left to right ratio and a normal appearance on DMSA scintigraphy, despite the presence of an acute renal infection. At that time, the authors were unaware that hyperfiltration is a common phenomenon in patients with acute renal infection and that their normal values could have been significantly overestimated. The present work therefore aimed to re-appraise these normal values. In a first step, in order to verify the previous results, the same type of population was selected, namely patients with present or past urinary tract infection but normal images and a normal left to right ratio on DMSA scintigraphy. In a second step, the selection was based on patients who had had no recent urinary tract infection. In both series, a single blood sample method was used for the evaluation of {sup 51}Cr-EDTA clearance. In the first group of patients, the results obtained were almost identical to those previously published. In the second group of patients, the results were significantly lower: after 2 years of age, the mean GFR value was 104 ml/min/1.73 m{sup 2} (10th and 90th percentiles 81 and 135 ml/min/1.73 m{sup 2}, respectively), compared with 117 ml/min/1.73 m{sup 2} in the first group. The data of the second group are probably more representative of the true normal GFR values and can be applied to the entire paediatric population. (orig.)

  16. Urinary bladder blood flow. I. Comparison of clearance of locally injected 99mtechnetium pertechnate and radioactive microsphere technique in dogs

    DEFF Research Database (Denmark)

    Krøyer, Kristian; Bülow, J; Nielsen, S L

    1990-01-01

    The blood flow of the dog urinary bladder measured by radioactive microsphere technique was compared to the clearance of locally injected 99mTechnetium pertechnate (99mTc) in the bladder wall. In semilogarithmic plots the 99mTc washout curves showed a multiexponential course. From the initial...... slopes (median 5.7 min) the bladder blood flow was calculated to be only 30-62% of the results obtained from the radioactive microsphere technique (blood flow in the muscular layer 21.7-44.8 ml/100 g/min). These lower values imply that the rate of removal of the hydrophilic tracer 99mTc at these flow...... blood flow....

  17. Glomerular filtration rate estimated from the uptake phase of 99mTc-DTPA renography in chronic renal failure

    DEFF Research Database (Denmark)

    Petersen, L J; Petersen, J R; Talleruphuus, U

    1999-01-01

    The purpose of the study was to compare the estimation of glomerular filtration rate (GFR) from 99mTc-DTPA renography with that estimated from the renal clearance of 51Cr-EDTA, creatinine and urea.......The purpose of the study was to compare the estimation of glomerular filtration rate (GFR) from 99mTc-DTPA renography with that estimated from the renal clearance of 51Cr-EDTA, creatinine and urea....

  18. Measurement of glomerular filtration rate by impulse synthesis: Clinical validation and optimization

    International Nuclear Information System (INIS)

    Palagi, B.; Verga, P.; Broggi, A.; Picozzi, R.; Villa, F.; Guzzini, F.; Cozzi, C.; Tomasi, A.

    1988-01-01

    Impulse synthesis is a technique which relies upon the logic of continuous infusion but extracts the clearance value from single-injection data by shifting and adding them until an asymptotic value is attained. This study has been aimed at validating and optimizing clinically the measurement of glomerular filtration rate by impulse synthesis. A single intravenous injection of 51 Cr-EDTA has been made in 32 patients and plasma activity monitored over the next 6 h. Glomerular filtration rate computed by a single-exponential fit method (GFR-SEF) has been shown to be significantly (p [de

  19. Capillary permeability of 99mTc-DTPA in canine myocardium determined by intracoronary bolus injection and residue detection

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Efsen, F; Haunsø, S

    1989-01-01

    chest dogs (group A) these indicators were administered separately as bolus injections into a cannulated diagonal branch of the left anterior descending coronary artery (LAD) and the curve of the response function was recorded by external activity registration. In further experiments on closed and open...... chest dogs (group B) 99mTc-DTPA was injected via a coronary angiography catheter into the ostium of the left coronary artery and the response curve was obtained by external registration. Regional myocardial perfusion coefficients were determined by the local 133xenon washout technique and from kinetic...... by local 133Xe washout technique. Mean values of the extraction fractions (E) were 0.463 and 0.475 for 99mTc-DTPA and 51Cr-EDTA, and the permeability-surface area products (PdS) were 52.8 and 57.5 ml.min-1.100 g-1 respectively. At the conventional capillary surface area estimate of 500 cm2.g-1...

  20. Human pharmacokinetics of iohexol. A new nonionic contrast medium

    International Nuclear Information System (INIS)

    Olsson, B.; Aulie, A.; Sveen, K.; Andrew, E.

    1983-01-01

    The pharmacokinetics of iohexol, a new nonionic, water-soluble contrast medium, have been determined after intravenous injection in 20 healthy volunteers, at four different dose levels (125-500 mg I/kg). The apparent volume of distribution was 0.27 1/kg, indicating distribution in the extracellular water. The biologic half-life was 121 minutes, comparable with that of other intravascular contrast media. Iohexol was excreted completely unmetabolized in the urine, with a 100% recovery 24 hours after injection. A comparison of iohexol and chromium-51 ( 51 Cr)-EDTA clearances indicates that iohexol is mainly excreted by glomerular filtration. The 51 Cr-EDTA clearance was the same when injected separately and concomitantly with iohexol, indicating that glomerular filtration rate is not affected by iohexol. No dose dependency was observed in the investigated parameters t1/2 alpha, t1/2 beta, Vd, ClT or ClR. Iohexol pharmacokinetics are in correspondence with previously reported data on intravascular contrast media

  1. [Renal excretion of methylene-diphosphate-technium-99m. Preliminary observations].

    Science.gov (United States)

    Vattimo, A; Martini, G

    1983-11-30

    The purpose of this study is to elucidate the mechanism of the renal excretion of 99mTc-MDP in man. We compared the renal clearance of 99mTc-MDP and 51Cr-EDTA (glomerular filtration rate agent). Since the 99mTc-MDP is bound to the plasma protein, the free fraction was calculated by dialysis. The clearances were obtained by single-injection technique. The plasma disappearance of the tracers was resolved into three exponential functions and area was calculated. The clearance was calculated by dividing the amount of the tracers excreted during the first four hours and the plasma area. In this study no difference was found in the clearance of the two agents. These findings suggest that the renal excretion of diphosphonate is related to the glomerular filtration rate.

  2. Aspects of osseous, peritoneal and renal handling of bisphosphonate during peritoneal dialysis: a methodological study

    DEFF Research Database (Denmark)

    Joffe, P; Henriksen, Jens Henrik

    1996-01-01

    to continuous ambulatory peritoneal dialysis (CAPD). The aims were: to assess the kinetics of 99m-technetium MBP (99mTc-MBP) in CAPD, and to evaluate the correctness of the assumption that the peritoneal and renal clearances of 99mTc-MBP equal the total plasma clearance of 51-chromium ethylenediamine tetra......Tc-MBP equal the clearances of 51Cr-EDTA is correct from a clinical point of view. We found that the uptake of the tracers in soft tissue and the renal handling of 51Cr-EDTA and 99mTc-MBP are also similar. The differences between the clearance values for 51Cr-EDTA and 99mTc-MBP may be explained...

  3. The form and interpretation of clearance curves for injected radioisotopes based on negative power laws, especially for 47Ca and estimated bone accretion rate

    International Nuclear Information System (INIS)

    Wise, M.E.

    1978-01-01

    Many hundreds of clearance curves for plasma and urine after a single injection of tracer are well fitted by y=Σsub(i=1)sup(r)Asub(i)exp(-Bsub(i)t),r=2 or 3, based on models with homogeneous compartments. Reanalyzing such sums as in a plot of log y versus log t shows that many of the original curves would fit y=Atsup(-α) or Atsup(-α)exp(-βt) over wide ranges of time and specific activity. Results of such reanalyses for a complete published series for serum albumin 131 I are given, and an outline of those for various compounds in the human body labeled by 3 H. For radiocalcium two such power laws can be fitted in one curve, with a transition between about 1 and 3 days, so that much of the log y versus log t plot consists of two straight lines. These lines are used for starting a numerical analysis that splits the curve into 2 non-linear components, plus a third one that is negligible after 5 min from injection. An outline of the iteration method is given. The components are interpreted physiologically and used to predict total bone activities by (de)convolution, and these are compared with observed ankle activities and with excretion rates. The bone accretion rate is obtained mainly from the middle component and comes to 2 to 3 g Ca/day, while return of 47 Ca from bone to plasma begins at about 1/2 day. These results seem incompatible while any based on compartments. The concept of biological half-life then needs to be reconsidered. (Auth.)

  4. Estimating GFR in children with 99mTc-DTPA renography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Møller, Michael L; Pfeifer, Andreas K

    2010-01-01

    study was to evaluate the accuracy of this non-invasive method in children. We calculated GFR from (99m)Tc-diethylene triamine pentaacetic acid (DTPA) renography and compared with (51)Cr-EDTA plasma clearance of 29 children between the age of 1 month and 12 years (mean 4.7 years). The correlation...... between (99m)Tc-DTPA renography and (51)Cr-EDTA plasma clearance was for all children R = 0.96 (n = 29, PTc-DTPA renography is reliable...

  5. Mucociliary clearance

    DEFF Research Database (Denmark)

    Munkholm, Mathias; Mortensen, Jann

    2014-01-01

    Mucociliary clearance has long been known to be a significant innate defence mechanism against inhaled microbes and irritants. Important knowledge has been gathered regarding the anatomy and physiology of this system, and in recent years, extensive studies of the pathophysiology related to lung...... pharmacological interventions on clearance rate, to study the importance of defective mucus clearance in different lung diseases or as a diagnostic tool in the work-up of patients with recurrent airway diseases. The aim of this review is to provide an overview of the anatomy, physiology, pathophysiology...

  6. Measurement of glomerular filtration rate (GFR) with 99mTc-DTPA and semiconductors minidetectors: further validation of the method

    International Nuclear Information System (INIS)

    Mahlstedt, J.; Muehlbauer, J.; Schrott, K.H.; Wolf, F.

    1982-01-01

    A technique measuring external radiation with semiconductor minidetectors (SCM) by use of a portable solid state memory after bolus injection of 1mCi 99mTc-DTPA is described. The correlation of the calculated clearances to plasma creatinine levels and to endogenous creatinine clearance as well is satisfactory. This new technique is compared with a standard steady state technique (GFR-SS) using 51 Cr-EDTA. GFR-SCM is strongly correlated to GFR-SS as standard method, therefore the data provides substantial evidence that GFR-SCM is a reliable method of GFR measurement. The advantages are: fast availability of the test result especially when calculated by use of a minicomputer; ease of performance in routine work; convenience for the patient without need of compliance and low costs for the detector system

  7. Whole-body microvascular permeability of small molecules in man

    DEFF Research Database (Denmark)

    Henriksen, J H

    1985-01-01

    In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured by the indica......In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured...

  8. Creatinine clearance test

    Science.gov (United States)

    Serum creatinine clearance; Kidney function - creatinine clearance; Renal function - creatinine clearance ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ...

  9. Initial effect of enalapril on kidney function in patients with moderate to severe chronic nephropathy

    DEFF Research Database (Denmark)

    Kamper, A L; Thomsen, H S; Nielsen, S L

    1990-01-01

    in their renal function. Thirty-one patients were studied, 26 on chronic antihypertensive treatment with drugs other than ACE inhibitors and 5 untreated normotensive. 51Cr-EDTA plasma clearance and renal technetium-99m dimercaptosuccinic acid (99mTc-DMSA) scintigraphy were made before and 24 h after start...

  10. Renal impairment and late toxicity in germ-cell cancer survivors

    DEFF Research Database (Denmark)

    Lauritsen, J.; Mortensen, M. S.; Kier, M. G. G.

    2015-01-01

    cohort of germ-cell cancer survivors. Patients and methods BEP-treated patients (N = 1206) were identified in the Danish DaTeCa database, and merged with national registers to identify late toxicity. GFR were measured (51Cr-EDTA clearance) before and after treatment and at 1, 3 and 5-year follow...

  11. Myocardial capillary permeability for small hydrophilic indicators during normal physiological conditions and after ischemia and reperfusion

    DEFF Research Database (Denmark)

    Svendsen, J H

    1991-01-01

    Myocardial capillary permeability for small hydrophilic solutes (51Cr-EDTA or 99mTc-DTPA) has been measured using intracoronary indicator bolus injection and external radioactivity registration (the single injection, residue detection method). The method is based on kinetic separation...

  12. Enrichment of Ly6Chi monocytes by multiple GM-CSF injections with HBV vaccine contributes to viral clearance in a HBV mouse model.

    Science.gov (United States)

    Zhao, Weidong; Zhou, Xian; Zhao, Gan; Lin, Qing; Wang, Xianzheng; Yu, Xueping; Wang, Bin

    2017-12-02

    Adjuvants are considered a necessary component for HBV therapeutic vaccines but few are licensed in clinical practice due to concerns about safety or efficiency. In our recent study, we established that a combination protocol of 3-day pretreatments with GM-CSF before a vaccination (3 × GM-CSF+VACCINE) into the same injection site could break immune tolerance and cause over 90% reduction of HBsAg level in the HBsAg transgenic mouse model. Herein, we further investigated the therapeutic potential of the combination in AAV8-1.3HBV-infected mice. After 4 vaccinations, both serum HBeAg and HBsAg were cleared and there was a 95% reduction of HBV-positive hepatocytes, in addition to the presence of large number of infiltrating CD8 + T cells in the livers. Mechanistically, the HBV-specific T-cell responses were elicited via a 3 × GM-CSF+VACCINE-induced conversion of CCR2-dependent CD11b + Ly6C hi monocytes into CD11b + CD11c + DCs. Experimental depletion of Ly6C hi monocytes resulted in a defective HBV-specific immune response thereby abrogating HBV eradication. This vaccination strategy could lead to development of an effective therapeutic protocol against chronic HBV in infected patients.

  13. Comparative evaluation of iohexol and inulin clearance for glomerular filtration rate determinations

    International Nuclear Information System (INIS)

    Lindblad, H.G.; Berg, U.B.

    1994-01-01

    The authors have evaluated iohexol as a filtration marker in 150 children. The clearance of iohexol was compared with that of inulin or with a formula clearance. The single-sample clearance of iohexol showed a good correlation with the clearance of inulin. The clearance of iohexol correlated well with the formula clearance. The optimal blood sampling time for iohexol clearance determinations appears to be between 120 and 180 min after injection, at least in patient with relatively normal filtration rates. It is concluded that iohexol clearance is an accurate method of determining the glomerular filtration rate in clinical practice. 25 refs., 5 figs

  14. Behaviour of solute and particle markers in the stomach of sheep given a concentrate diet

    International Nuclear Information System (INIS)

    Faichney, G.J.; Griffiths, D.A.

    1978-01-01

    Fistulated sheep given a concentrate diet were used to study the behaviour of solute ([ 51 Cr]EDTA) and particle ([ 103 Ru]phenanthroline) markers in the stomach under conditions of continuous feeding. An injection of a mixed dose of [ 51 Cr]EDTA and [ 103 Ru]phenanthroline was given into the rumen and the time course of marker concentrations in the rumen and the abomasum was recorded. The curves were analysed on the assumption that the stomach of the sheep could be represented as two mixing compartments (reticulo-rumen and abomasum) and a time delay (omasum). This model provided a very good description of the data. [ 103 Ru]-phenanthroline associated with small particles was retained in the rumen much longer than [ 51 Cr]EDTA. Although exchange of [ 103 Ru] phenanthroline occurred between large and small particle fractions, the results suggested that small particles may have been retained somewhat longer in the rumen than solutes. However, it was clear from the results that the mean retention times for particulate matter in the rumen could not be simply obtained using adsorbable markers. Cyclical fluctuations in the concentration of [ 51 Cr]EDTA in the rumen indicated that there were daily variations in net water flux in the rumen. The presence of protozoa was associated with much shorter retention times of both solutes and particles in the rumen. Protozoa were also associated with reduced rumen volumes. (author)

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Treatments and Therapies Airway Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. ... or caregiver. Older kids and adults can choose ACTs that they can do on their own. Share ...

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast ... Facebook Twitter ...

  17. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. Most are easy to ...

  18. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy ... clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall ...

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage ... LEGACY GIFT Sponsor a Participant CF Climb CF Cycle for Life Great Strides Xtreme Hike Participate In ...

  1. Lung mucociliary clearance

    International Nuclear Information System (INIS)

    Mortensen, J.; Lange, P.; Nyboe, J.; Groth, S.

    1994-01-01

    The aim of this study was to establish reference values for mucociliary clearance and mucociliary clearance reserve capacity as determined by β 2 -adrenergic agonist-induced increase in mucociliary clearance. We studied 62 healthy females (n=33) and males (n=29). Their ages ranged evenly between 18 and 84 years. Fifty-three of the subjects were life-long non-smokers, while nine were ex-smokers. Multiple linear regression analyses showed that mucociliary clearance was significantly faster when the radioaerosol was deposited in the central airways than when it was deposited in the peripheral airways, and faster in life-long non-smokers than in ex-smokers. There was no influence of age, and no convincing association with sex. The variation was less within than between subjects. Mean mucociliary clearance reserve capacity was 21.3% (SD: 10.0%, P 2 agonist-induced increase in lung mucociliary clearance was significantly larger (P<0.05) than the stimulation which has previously been reported in patients with asthma, bronchiectasis or cystic fibrosis. The signal-to-noise ratio of the mucociliary clearance reserve capacity in relation to measurement of baseline mucociliary clearance indicates that measurement of mucociliary clearance reserve capacity may be a more efficient means of distinguishing between ''normal'' and ''abnormal'' mucociliary clearance than single measurement of baseline mucociliary clearance. (orig.)

  2. Noninvasive determination of individual renal clearance

    International Nuclear Information System (INIS)

    Chanard, J.; Brunois, J.P.; Ruiz, J.C.; Assailly, J.

    1980-01-01

    A noninvasive method for measurement of individual renal clearance is presented, based on analysis of the early rise of the kidneys' time-activity curves after injection of an appropriate tracer ( 131 I-ortho-iodohippurate for tubular function or 111 In DTPA for glomerular clearance). The analysis is based on the assumption that an insignificant amount of tracer leaves the kidney during the first few moments following injection. Therefore, the kidney activity during this period is directly proportional to the integral of the blood (heart) activity. After blood background subtraction, the linear correlation between the early part of the renogram and the corresponding blood integral activity curve allows calculation of an angular coefficient. The ratio of these coefficients calculated for each kidney is proportional to the ratio of the individual clearances. The latter are calculated from the total clearance simultaneously measured using a simplified method without urine collection. In control subjects with normal renal function individual renal clearances were not significantly different. In uninephrectomized patients a precision of 5% in calculating individual clearance was estimated from data recorded at the level of the remaining kidney. In patients with functional asymmetry, results were compared with 197 HgCl 2 quantitative renal fixation. A linear correlation was found (r = 0.95). The method we propose seems valuable for clinical investigation and allows sequential measurements. (orig.)

  3. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center Study Services Working With the TDN Tools and Resources ...

  4. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center ...

  5. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Research Consortia CF Biomarker Consortium CFTR 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ...

  6. Security Clearance Tracking System

    Data.gov (United States)

    National Archives and Records Administration — SCTS supports the adjudication process of private background investigations and clearances for potential employees, contractors, interns and student workers.

  7. Skeletal muscle oxygen pressure fields in artificially ventilated, critically ill patients

    International Nuclear Information System (INIS)

    Lund, N.; Jorfeldt, L.; Lewis, D.H.; Oedman, S.

    1980-01-01

    The MDO (Mehrdraht Dostmund Oberflaeche) oxygen electrode was used in a study of skeletal muscle oxygen pressure fields, presented as histograms, in critically ill patients artificially ventilated with gas mixtures of different oxygen concentrations. The histograms were compared with forearm blood flow measurements performed with strain gauge plethysmography. Local blood flow and permeability-surface area product (PS) were also studied by the simultaneous clearances of 133 xenon and 51 Cr-EDTA. The histogram distribution type was normal, i.e. approximately Gaussian, at arterial oxygen pressure levels between 10 and 18 kPa. At arterial oxygen pressures outside this range the histogram distribution types were abnormal, i.e. they showed a non-symmetrical distribution of oxygen pressure values, but their mean was approximately the same as in the normal histogram. However, there were significantly higher tissue oxygen pressure mean values in the patients (3.43 kPa) than in a group of healthy human volunteers (2.25 kPa). Mean forearm blood flow and the clearances of 133 xenon and 51 Cr-EDTA showed marked variations during the measurements both intraindividually and interindividually. Mean forearm blood flow and mean clearances of 133 xenon showed opposite trends compared with arterial oxygen pressures. Mean clearances of 51 Cr-EDTA and mean PS showed minor variations at the different arterial oxygen pressure levels. (author)

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Team Your cystic fibrosis care team includes a group of CF health care professionals who partner with ... Awards and Grants Career Development Awards Research Awards Training Awards CF ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your ...

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... and Their Families When There's More Than One Person With CF in the Same School Daily Life ... Awards and Grants Career Development Awards Research Awards Training Awards CF ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your ...

  10. Comparative animal studies for the determination of the extracellular space with several radioactively labelled substances

    International Nuclear Information System (INIS)

    Pippart, S.

    1973-01-01

    The volume of the total extracellular space and of the extracellular space of the organs (liver, lungs, heart, spleen, brain) was determined with the aid of 5 radioactively labelled substances, each in 10 rats. The test substances (inulin- 3 H, 51 Cr-EDTA, thiosulfate- 35 S, NH 4 - 82 Br, 60 Co-vitamin B 12 ) are described in the relevant literature as substances for the determination of the extracellular space and as clearance substances. (BSC/AK) [de

  11. Comparative study between in Vivo and Vitro radionuclide technique in measurement of Glomerular filtration rate

    International Nuclear Information System (INIS)

    Ziada, G.; Moustafa, H.; Elhaddad, SH.; Taalab, KH.

    1995-01-01

    Fifty patients were referred to nuclear medicine department in NEMROCK center for measurement of glomerular filtration rate (GFR). The group included 34 males and 16 females with a mean age of 38.3 ± 10.7 years. Estimation of GFR was done using 111-185 mBq of 99m Tc-DTPA with data collected on 128 x 128 matrix on IDAC computer every 15 seconds with calculation of renal uptake and GFR applying Gates method. 72 hours, a dose 3.7 mBq of 51 Cr-EDTA with 2 blood samples taken at 120, 240 minutes with estimation of plasma clearance using Russel et al., method (1985). The mean clearance of 51 Cr-EDTA was 79.61±22.4 ml/min compared to 84.34±26.3 ml/min. Using direct scintigraphic method with positive correlation using regression analysis (r=0.96). Also, both 51 Cr-EDTA and in vivo 99m Tc-DTPA were positively correlated with creatinine clearance (r=0.87 and 0.91 respectively). A modified regression formulas was used for correction of the results of 99m Tc-DTPA values GFR ( 99m Tc-DTPA) x 0.81 + 11 ± 6.4 ml/min. 4 figs., 1 tab

  12. Comparative study between in Vivo and Vitro radionuclide technique in measurement of Glomerular filtration rate

    Energy Technology Data Exchange (ETDEWEB)

    Ziada, G; Moustafa, H; Elhaddad, SH; Taalab, KH [Nuclear medicine department, Faculty of medicine, Cairo university, Cairo, (Egypt)

    1995-10-01

    Fifty patients were referred to nuclear medicine department in NEMROCK center for measurement of glomerular filtration rate (GFR). The group included 34 males and 16 females with a mean age of 38.3 {+-} 10.7 years. Estimation of GFR was done using 111-185 mBq of {sup 99m} Tc-DTPA with data collected on 128 x 128 matrix on IDAC computer every 15 seconds with calculation of renal uptake and GFR applying Gates method. 72 hours, a dose 3.7 mBq of {sup 51} Cr-EDTA with 2 blood samples taken at 120, 240 minutes with estimation of plasma clearance using Russel et al., method (1985). The mean clearance of {sup 51} Cr-EDTA was 79.61{+-}22.4 ml/min compared to 84.34{+-}26.3 ml/min. Using direct scintigraphic method with positive correlation using regression analysis (r=0.96). Also, both {sup 51} Cr-EDTA and in vivo {sup 99m} Tc-DTPA were positively correlated with creatinine clearance (r=0.87 and 0.91 respectively). A modified regression formulas was used for correction of the results of {sup 99m} Tc-DTPA values GFR ({sup 99m}Tc-DTPA) x 0.81 + 11 {+-} 6.4 ml/min. 4 figs., 1 tab.

  13. Myocardial capillary permeability for small hydrophilic indicators during normal physiological conditions and after ischemia and reperfusion

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup

    1991-01-01

    Myocardial capillary permeability for small hydrophilic solutes (51Cr-EDTA or 99mTc-DTPA) has been measured using intracoronary indicator bolus injection and external radioactivity registration (the single injection, residue detection method). The method is based on kinetic separation of the inje......Myocardial capillary permeability for small hydrophilic solutes (51Cr-EDTA or 99mTc-DTPA) has been measured using intracoronary indicator bolus injection and external radioactivity registration (the single injection, residue detection method). The method is based on kinetic separation...... including microvascular alterations. In open chest dogs transitory increases in capillary extraction fraction and PdS for small hydrophilic solutes were seen following 20 minutes of regional myocardial ischemia and reperfusion. This response could be inhibited by treatment directed against superoxide...

  14. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway ... on their own. Share Facebook Twitter Email More options Print Share Facebook Twitter Email Print Permalink All ...

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  17. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living longer and ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  18. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in CF Clinical Care Guidelines Cystic Fibrosis-Related Diabetes Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care Guidelines Chronic Medications to Maintain Lung ...

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Make a Charitable Gift Our Corporate Supporters Workplace Engagement DONATE YOUR PROPERTY eCards for a Cure About ... airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  1. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: March 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  2. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center Study ...

  3. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care ... attack bacteria. Choose What's Best for You Your respiratory therapist or another member of your CF care ...

  4. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: June 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  5. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... decisions about your health care. CF Genetics: The Basics CF Mutations Video Series Find Out More About ... of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing and ...

  6. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from ...

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... people with cystic fibrosis so that they make smart decisions about CF-related research, treatment, and access ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in part to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of ... a cure for CF and supports a broad range of research initiatives to tackle the disease from ...

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Physical Therapy Coughing and Huffing High-Frequency Chest Wall Oscillation Positive Expiratory Pressure Clinical Trials Clinical Trials ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... CFTR Modulator Therapies Mucus Thinners Nebulizer Care at Home Vascular Access Devices PICCs and Ports Partnerships for ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... many challenges, including medical, social, and financial. By learning more about how you can manage your disease every day, you can ultimately help find a ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic ...

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing ... Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall Oscillation ( ...

  14. Generic clearance values

    International Nuclear Information System (INIS)

    Bossio, M.C.; Muniz, C.C.

    2009-01-01

    This paper analyzes the Generic Clearance Values established for natural and artificial radionuclides with the objective of evaluating their degree of conservatism in views of adopting them into the regulatory body. Generic clearance values for natural radionuclides have been chosen by experts judgments as the optimum boundary between, on one hand, the ubiquitous unmodified soil concentrations and, on the other hand, activity concentrations in ores, mineral sands, industrial residues and wastes. For artificial radionuclides the clearance levels have been derived from the scenarios postulated in the document 'Safety Reports Series Nr 44' of the IAEA considering quantitative exemption criteria. A set of 8 scenarios were postulated covering external, ingestion and inhalation exposure pathways. For each radionuclide, the generic clearance level was derived as the more restrictive value obtained from the scenarios, that is the lowest ratio between the applicable individual dose and the dose per unit activity concentration (Bq/g). The individual dose was calculated by a formula depending on each scenario and pathway, with different parameters, such as exposure time, dosimetric factors, dilution factor, density of the material, geometric factors, etc. It was concluded that the basis and parameters used for the derivation of the generic clearance levels are quite conservative and therefore its the adoption in Argentina has been recommended. It is expected that their implementation will contribute to optimize the regulatory management system. (author)

  15. Generic Clearance Values

    International Nuclear Information System (INIS)

    Bossio, M.C.; Muniz, C.C.

    2010-01-01

    This paper analyzes the Generic Clearance Values established for natural and artificial radionuclides with the objective of evaluating their degree of conservatism in views of adopting them into the regulatory body. Generic clearance values for natural radionuclides have been chosen by experts judgments as the optimum boundary between, on the one hand, the ubiquitous unmodified soil concentrations and, on the other hand, activity concentrations in ores, mineral sands, industrial residues and wastes. For artificial radionuclides the clearance levels have been derived from the scenarios postulated in the document Safety Reports Series 44 of the IAEA considering quantitative exemption criteria. A set of 8 scenarios were postulated covering external, ingestion and inhalation exposure pathways. For each radionuclide, the generic clearance level was derived as the more restrictive value obtained from the scenarios, that is the lowest ratio between the applicable individual dose and the dose per unit activity concentration (Bq/g). The individual dose was calculated by a formula depending on each scenario and pathway, with different parameters, such as exposure time, dosimetric factors, dilution factor, density of the material, geometric factors, etc. It was concluded that the basis and parameters used for the derivation of the generic clearance levels are quite conservative and therefore its the adoption in Argentina has been recommended. It is expected that their implementation will contribute to optimize the regulatory management system. (authors) [es

  16. Study on clearance system

    International Nuclear Information System (INIS)

    Onishi, Yuko; Miura, Hiroshi; Kawasaki, Satoru

    2011-01-01

    The clearance system is a legal system to release 'the radioactive waste not requiring treatment as radioactive waste' from the regulatory control. JNES supports NISA on approval and confirmation of clearance measurement and judgment developed by the operator. The objective of this study is to establish technical base of the validation method of the clearance measurement for various objects. In reactor facilities, the bulk measurement technique or the statistical sampling measurement technique may be applied to large scale objects or concrete walls. In this study, the criteria of those techniques were examined. In uranium processing facilities, it is important to confirm surface state of the object in case of detecting alpha rays. The result of the examination about the influence of the surface rust in the uranium clearance measurement by the alpha ray measurement showed that the pollution was distributed in rust layer uniformly. This result will be reflected to the revision of the Ministerial Ordinance on Clearance in 2011FY. To develop a manual for unexpected incidents, the response procedure for an unexpected incident was prepared, including a response system. (author)

  17. Glomerular filtration rate by {sup 51}chomium and {sup 113m}indium labeled EDTA in horses; Taxa de filtracao glomerular pelo EDTA marcado com {sup 51}cromo e com {sup 113m}indio em equinos

    Energy Technology Data Exchange (ETDEWEB)

    Maliska, C.; D' Almeida, J.; Pellegrini, P.M.; Schimit, T.S. [Hospital Central do Exercito (HCE), Rio de Janeiro, RJ (Brazil). Servico de Medicina Nuclear; Pinho, W.R. [Centro de Ensino Superior, Valenca, RJ (Brazil). Fac. de Medicina Veterinaria; Lima, J.E.T. [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil). Servico de Medicina Nuclear

    2009-07-01

    The glomerular filtration rate was determined in nine healthy horses, six male and three female, aged two to 12-year-old, by means of {sup 51}Cr and {sup 113m}In labeled EDTA single injection technique. The glomerular filtration rate was calculated from the plasma disappearance curve and the volume of distribution of the radiotracer, {sup 51}Cr-EDTA or {sup 113m}In-EDTA. The result (mean +- standard deviation) was 148.80 +- 26.42 m L.min{sup -1}.100 kg. It is concluded that the measurement of glomerular filtration rate by {sup 51}Cr-EDTA or {sup 113m}In-EDTA by single injection technique eliminates the bladder catheterization, and for its simplicity, convenience, accuracy, and low dose of radiation, can be used in horses as a method of choice in clinical routine. (author)

  18. Chromium 51 EDTA/technetium 99m MDP plasma ratio to measure total skeletal function

    Energy Technology Data Exchange (ETDEWEB)

    Nisbet, A.P.; Edwards, S.; Lazarus, C.R.; Malamitsi, J.; Maisey, M.N.; Mashiter, G.D.; Winn, P.J. (Guy' s Hospital, London (UK))

    1984-08-01

    A method is described for the quantitation of total skeletal activity during bone scans. The method requires a single plasma sample only, taken at the time of imaging. The ratio of % injected dose of /sup 51/Cr EDTA to that of /sup 99/Tcsup(m) MDP is calculated from this sample following combined injection of the two radiopharmaceuticals. The /sup 51/Cr EDTA level corrects for the glomerular filtration of /sup 99/Tcsup(m) MDP. Using this method, which only requires a gamma counter, significant differences from normal controls have been shown in patients with osteomalacia, renal osteodystrophy, Paget's disease and hypercalcaemia. The method provides routine quantitative data to add to the imaging information in the bone scan.

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... NACFC Carolyn and C Richard Mattingly Leadership in Mental Health Care Award Mary M. Kontos Award NACFC Reflections ... help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway clearance. ... Instagram Email Find a Clinical Trial Help us blaze ...

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage ...

  1. Study on clearance system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    The clearance system is a legal system to release 'the radioactive waste not requiring treatment as radioactive waste' from the regulatory control. JNES supports Nuclear Regulatory Agency on approval and confirmation of clearance measurement and judgment developed by the operator. The objective of this study is to establish technical base of the validation method of the clearance measurement for various objects. In uranium processing facilities, simulation sources emitting alpha-rays is used in a validity confirmation examination of the measuring equipment. In this study, these sources were examined by measuring alpha and beta spectra to evaluate the applicability and problem of these sources. In addition, the measuring method detecting gamma-rays was examined. This method can be applied to complicated objects. As a part to develop a manual for unexpected incidents in clearance system, a quick method for measurement of Strontium 90 was examined. In addition, the measuring methods for the judgment of the influence of fallout and for NR (Non-Radioactive) confirmation were examined. (author)

  2. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... cystic fibrosis. CF CARE CENTER finder We provide funding for and accredit more than 120 care centers ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  3. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast To learn more about how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist ...

  4. Isotope determinations of renal clearance equivalent with physiological clearance measurements

    International Nuclear Information System (INIS)

    Junges, R.

    1983-01-01

    The concept of renal clearance in nuclear medicine describes the tubular secretion and glomerular filtration of a substance being removed from the blood plasma. The concept of clearance as used physiologically is rather wider and includes consideration of the outflow of the substances remained back in the kidneys. The present paper discusses clearance measurements as seen from a thermodynamic point of view, in which isotope clearances become equivalent with the physiological concept of clearance. In addition, it is possible to quantify each single step of the excretory function of each kidney separately. (orig.) [de

  5. Clearance of labelled creatinine

    International Nuclear Information System (INIS)

    Eberstadt, P.; Liverant, J.

    1982-01-01

    Creatinine, extensively used in clinical work to evaluate glomerular filtration rate (G.F.R.) has caused controversy. Using simultaneously on dogs a gamma emitting agent measuring G.F.R., creatinine clearance proved to be higher. Aided by quantitative determinations and compartmental analysis fortunately the respective dilution spaces can be calculated. In the majority of these animals creatinine spaces are larger but in some equal to the ones of inulin

  6. Rational customs clearance technology choice

    OpenAIRE

    Shramenko, N.; Andriets, V.

    2008-01-01

    Issues concerning cargo delivery efficiencyincrease by choice of rational customs clearance technology have been considered. Three possible variants of customs clearance andmethods which allow to define the most rational version of cargo delivery in international road communication based on main efficiency criteria for definite distance have been presented.

  7. Depressed reticuloendothelial clearance of platelets in rats after trauma.

    Science.gov (United States)

    Kaplan, J E; Moon, D G; Minnear, F L; Saba, T M

    1984-02-01

    Platelet microembolization may contribute to microcirculatory and organ damage following trauma and shock. It is hypothesized that posttraumatic reticuloendothelial depression predisposes to such microembolization by failure to clear altered platelets from the circulation. The present study evaluated the short-term (1 h) clearance and organ localization of radiolabeled homologous damaged platelets in normal rats and in rats following sublethal Noble-Collip drum trauma. Platelets were collected in citrated platelet-rich plasma from normal rats and labeled with 51Cr in citrated saline. Platelets were altered by repeated centrifugation in protein-free medium. These platelets differed functionally and morphologically from normal platelets. Disappearance of iv injected damaged platelets conformed to a two-compartment exponential clearance. Velocity of clearance in the rapid compartment correlated with hepatic platelet localization, whereas velocity of clearance in the second compartment correlated with splenic platelet localization. Clearance rate of the rapid compartment was depressed at 1 h after trauma and elevated at 24 h. These changes were associated with a decrease in hepatic platelet localization at 1 h and an increase above normal at 24 h. Splenic platelet localization was decreased by 3 h following trauma. Pulmonary platelet localization was increased at all times following trauma. It is concluded that the posttrauma state is associated with a defect in the reticuloendothelial system clearance of altered platelets, which may augment embolization of platelets in the lung.

  8. Body counter

    International Nuclear Information System (INIS)

    Koeppe, P.

    1975-01-01

    The paper gives a survey on some applications of the whole body counter in clinical practice and a critical study of its application as a routine testing method. Remarks on the necessary precautions are followed by a more detailed discussion of the determination of the natural potassium content, the iron metabolism, the vitamin B12 test, investigations of the metabolism of the bone using 47 Ca and 85 Sr, investigations with iodine and iodine-labelled substances, clearance investigations (in particular the 51 Cr EDTA clearance test), as well as the possibilities of neutron activation in vivo. (ORU/AK) [de

  9. Effect of renal venous pressure elevation on tubular sodium and water reabsorption in the dog kidney

    DEFF Research Database (Denmark)

    Abildgaard, U; Amtorp, O; Holstein-Rathlou, N H

    1988-01-01

    of [51Cr]EDTA was used as a measure of the rate of glomerular filtration (GFR). GFR, urinary excretion rates of sodium and water, and lithium clearance were used for assessing the absolute and fractional reabsorption rates of sodium and water in the proximal as well as in more distal segments......This study was performed in order to quantify the effects of renal venous pressure (RVP) elevation on absolute and fractional reabsorption rates of sodium and water in proximal and distal segments of the nephron in dog kidneys. Renal blood flow (RBF) was measured electromagnetically. Clearance...

  10. Metabolic clearance rate and urinary clearance of purified beta-core

    International Nuclear Information System (INIS)

    Wehmann, R.E.; Blithe, D.L.; Flack, M.R.; Nisula, B.C.

    1989-01-01

    We injected a highly purified preparation of the beta-core molecule, a fragment of hCG beta excreted in pregnancy urine, into five men and three women to determine its kinetic parameters, MCR, and urinary clearance. The beta-core molecule was distributed in an initial volume [1950 +/- 156 (mean +/- SEM) mL/m2 body surface area] approximately equal to the estimated plasma volume. Its disappearance was multiexponential on a semilogarithmic plot, with a rapid phase t1/2 of 3.5 +/- 0.7 min and a slow phase t1/2 of 22.4 +/- 4.2 min. The transit time (the mean time spent by a molecule of beta-core in transit) was 20.6 +/- 2.1 min. The MCR was 192.0 +/- 8.0 mL/min.m2 body surface area. About 5% of the injected dose of beta-core was excreted into the urine in the first 30 min after injection, and low levels of excretion persisted for up to 7 days. The urinary clearance rate of beta-core was 13.7 +/- 1.4 mL/min.m2, accounting for about 8% of the elimination of beta-core from the plasma. The beta-core immunoreactivity in serum and urine was characterized by gel filtration and three independent RIA systems to show that its properties were indistinguishable from those of the injected beta-core. Serum levels of beta-core in pregnant women were less than 0.2 ng/mL, while the amounts excreted in their urine were as much as 5 mg/day. Based on these clearance parameters of beta-core in normal subjects, less than 0.2% of the beta-core excreted in pregnancy urine is derived by urinary clearance of plasma beta-core. Therefore, more than 99% of the beta-core excreted in pregnancy urine is derived from beta-core in a compartment separate from plasma. In particular, these data indicate that there is relatively little placental secretion of beta-core into plasma and that placental secretion does not account for the vast majority of beta-core in pregnancy urine

  11. Aspects of osseous, peritoneal and renal handling of bisphosphonate during peritoneal dialysis: a methodological study

    DEFF Research Database (Denmark)

    Joffe, P; Henriksen, Jens Henrik Sahl

    1996-01-01

    to continuous ambulatory peritoneal dialysis (CAPD). The aims were: to assess the kinetics of 99m-technetium MBP (99mTc-MBP) in CAPD, and to evaluate the correctness of the assumption that the peritoneal and renal clearances of 99mTc-MBP equal the total plasma clearance of 51-chromium ethylenediamine tetra......-acetic acid (51Cr-EDTA). Eight patients on CAPD were studied cross-sectionally. The mean plasma clearances of 99mTc-MBP and 51Cr-EDTA in the steady state (4h) were 38.2 and 12.2 ml min-1 (p peritoneal clearances (0-4 h) were 5.2 and 7.2 ml min-1 (p ....5 and 2.8 ml min-1 (not significant), respectively. The bone bisphosphonate clearance (BBC) at steady state was 26.0 ml min-1, a value which was significantly higher than that at infinity (16.5 ml min-1, p peritoneal and renal clearances of 99m...

  12. Surfactant secretion and clearance in the newborn

    International Nuclear Information System (INIS)

    Stevens, P.A.; Wright, J.R.; Clements, J.A.

    1989-01-01

    Pregnant rabbits (30 days) were injected intravenously with [3H]choline 8 h before delivery. The fetuses were delivered, and lung lavage and lamellar body phospholipids (PL) were analyzed. Some newborns also received radioactively labeled surfactant intratracheally on delivery and were permitted to breathe. With time, intratracheal label decreased in lavage and appeared in the lamellar body fraction, and intravenous label accumulated in both pools. Using a tracer analysis for non-steady state, we calculated surfactant secretion and clearance rates for the newborn period. Before birth, both rates rose slightly from 1.8 micrograms PL.g body wt-1.h-1 at 6 h before birth to 7.3 at birth. Immediately after birth, secretion rate rose to 37.7 micrograms PL.g body wt-1.h-1. Between 1.5 and 2 h after birth it fell to a minimum of 1.8 micrograms PL.g body wt-1.h-1 and then rose slowly to 6.0 at 12 h. After birth, clearance rate increased less than secretion rate (maximum 24.7 micrograms PL.g body wt-1.h-1 shortly after birth) then followed the same pattern but did not balance secretion rate in the 1st day

  13. Intensified Multifactorial Intervention in Type 2 Diabetes and Microalbuminuria Reduces End Stage Renal Disease and Mortality

    DEFF Research Database (Denmark)

    Oellgaard, Jens; Gæde, Peter; Rossing, Peter

    2016-01-01

    -label trial. Duration of the intervention was 8 years, where after all patients were recommended intensified treatment. Total follow-up of up to 21 years of 24 hour urinary albumin excretion rate and GFR (51Cr-EDTA-clearance) assessed at 6 study visits. Information on end stage renal disease (ESRD......) and mortality was obtained from national registries. Outcome measures were progression to macroalbuminuria (>300 mg/24h), decline-rates of GFR and progression to end stage renal disease (ESRD) or death. Results: Progression to macroalbuminuria was reduced in the original intensive-therapy group with a hazard...

  14. Impact of lisinopril and atenolol on kidney function in hypertensive NIDDM subjects with diabetic nephropathy

    DEFF Research Database (Denmark)

    Nielsen, F S; Rossing, P; Gall, M A

    1994-01-01

    . Eight patients dropped out, and the results for the remaining 35 patients (16 lisinopril and 19 atenolol) are presented. Diuretics were required in 10 of 16 lisinopril patients and 12 of 19 atenolol patients. The following variables were measured: 24-hour ambulatory BP (Takeda TM2420), albuminuria...... (enzyme-linked immunosorbent assay), fractional albumin clearance, and glomerular filtration rate (GFR) ([51Cr]EDTA technique). The average reduction in mean arterial BP during the 12 months was identical in the two groups 12 +/- 2 vs. 11 +/- 1 mmHg in the lisinopril and atenolol group, respectively...

  15. Renal uptake of dimercaptosuccinic acid and glomerular filtration rate in chronic nephropathy at angiotensin converting enzyme inhibition

    International Nuclear Information System (INIS)

    Kamper, A.L.; Thomsen, H.S.; Nielsen, S.L.; Strandgaard, S.; Herlev Hospital

    1990-01-01

    Glomerular filtration rate (GFR) and renal uptake of dimercaptosuccinic acid (DMSA) were measured in 31 patients with progressive chronic nephropathy before and immediately after the start of treatment with angiotensin converting enzyme (ACE) inhibitor in order to control adverse effects on kidney function. Scintigrams of the kidneys showed an unaltered distribution of DMSA during treatment. GFR estimated by 51 Cr-EDTA plasma clearance fell by 14% (P 99m Tc-DMSA increased by 10% (P<0.01). It is concluded that DMSA in chronic renal failure is mainly taken up by the tubular cells from the peritubular capillaries since the uptake was unaffected by the acute decrease in GFR. (orig.)

  16. Urine liver fatty acid binding protein and chronic kidney disease progression

    DEFF Research Database (Denmark)

    Khatir, Dinah S; Bendtsen, Mette D; Birn, Henrik

    2017-01-01

    , regarding progression of chronic kidney disease (CKD). In a prospective study design a cohort of 74 stage 3-4 CKD patients (age 61 ± 13 years) were included. Glomerular filtration ratio (GFR, 51Cr-EDTA-clearance), 24-hour ambulatory BP, 24-hour urinary albumin/creatinine ratio (UAC) and urinary L......Excretion of the tubular protein liver fatty acid binding protein (L-FABP) is a potential novel biomarker of renal dysfunction. We examined whether urine L-FABP excretion adds prognostic information to the well-established risk markers, blood pressure (BP), albumin excretion and baseline GFR...

  17. Comparative animal studies for the determination of the extracellular space with several radioactively labelled substances

    Energy Technology Data Exchange (ETDEWEB)

    Pippart, S

    1973-01-01

    The volume of the total extracellular space and of the extracellular space of the organs (liver, lungs, heart, spleen, brain) was determined with the aid of 5 radioactively labelled substances, each in 10 rats. The test substances (inulin-/sup 3/H, /sup 51/Cr-EDTA, thiosulfate-/sup 35/S, NH/sub 4/-/sup 82/Br, /sup 60/Co-vitamin B/sub 12/) are described in the relevant literature as substances for the determination of the extracellular space and as clearance substances.

  18. Pathogenesis and treatment of diabetic glomerulopathy

    International Nuclear Information System (INIS)

    Marre, M.; Le Jeune, J.J.

    1995-01-01

    Diabetic glomerulopathy is the consequence, at the glomerular level, of diabetes. Diagnosis is based on the association of proteinuria, arterial hypertension and an early reduction of glomerular filtration in a diabetic patient, generally insulin-dependent. Diabetic glomerulopathy is a complication of type I diabetes, which begins in childhood or adolescence, but can also be discovered in type II diabetes. A definite diagnosis requires histological evidences ; glomerular clearance measurements ( 125 I-iodothalamate or 51 Cr-EDTA) yield important information concerning glomerular filtration. The authors subsequently address pathogenesis and therapeutic regimens, and they report on the particularities of this condition in type II diabetes. (authors). 30 refs., 2 tabs

  19. Endogenous pancreatic polypeptide in different vascular beds

    DEFF Research Database (Denmark)

    Henriksen, J H; Schwartz, Tania; Bülow, J B

    1986-01-01

    a significantly higher level of circulating PP than controls (n = 10): median PP = 52 (range 21 to 352) v 20 (6 to 143) pmol/L, respectively (P less than 0.02). Circulating PP was inversely correlated to 51Cr-EDTA plasma clearance (r = -0.57, P less than 0.02, n = 14) and directly correlated to serum creatinine...... a progressively increasing rate of PP secretion in subjects with raised circulating PP. No statistically significant difference could be detected between systemic and renal venous PP or across the lung, left adrenal gland, or lower limb. Assuming steady state between secretion and biodegradation, the metabolic...

  20. Endogenous pancreatic polypeptide in different vascular beds: relationship to release and degradation in subjects with normal and decreased kidney function

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Schwartz, T W; Bülow, J B

    1986-01-01

    a significantly higher level of circulating PP than controls (n = 10): median PP = 52 (range 21 to 352) v 20 (6 to 143) pmol/L, respectively (P less than 0.02). Circulating PP was inversely correlated to 51Cr-EDTA plasma clearance (r = -0.57, P less than 0.02, n = 14) and directly correlated to serum creatinine...... a progressively increasing rate of PP secretion in subjects with raised circulating PP. No statistically significant difference could be detected between systemic and renal venous PP or across the lung, left adrenal gland, or lower limb. Assuming steady state between secretion and biodegradation, the metabolic...

  1. Renal uptake of dimercaptosuccinic acid and glomerular filtration rate in chronic nephropathy at angiotensin converting enzyme inhibition

    DEFF Research Database (Denmark)

    Kamper, A L; Thomsen, H S; Nielsen, S L

    1990-01-01

    function. Scintigrams of the kidneys showed an unaltered distribution of DMSA during treatment. GFR estimated by 51Cr-EDTA plasma clearance fell by 14% (P less than 0.01), but renal uptake of 99mTc-DMSA increased by 10% (P less than 0.01). It is concluded that DMSA in chronic renal failure is mainly taken......Glomerular filtration rate (GFR) and renal uptake of dimercaptosuccinic acid (DMSA) were measured in 31 patients with progressive chronic nephropathy before and immediately after the start of treatment with angiotensin converting enzyme (ACE) inhibitor in order to control adverse effects on kidney...

  2. The renal handling of sodium and water is not affected by the standard-dose cisplatin treatment for testicular cancer

    DEFF Research Database (Denmark)

    Daugaard, G; Strandgaard, S; Holstein-Rathlou, N H

    1987-01-01

    Renal clearances of 51Cr-EDTA, lithium, sodium and potassium were measured before and after each of four consecutive treatment series with cisplatin in 15 men with testicular cancer. Since lithium is reabsorbed like sodium and water in the proximal tubules, but not reabsorbed to any measurable...... and all other parameters of glomerular filtration and renal sodium handling remained normal throughout the study (with the exception of a fall in fractional sodium excretion after the first treatment series). Plasma magnesium declined during all four treatment periods, signifying renal magnesium wasting....

  3. Glomerular filtration in kidney recipients measured by plasma clearance of 169Yb-DTPA

    International Nuclear Information System (INIS)

    Stribrna, J.; Oppelt, A.; Jirickova, E.; Janata, V.; Kocandrle, V.; Sup, I.; Woller, P.; Franke, W.G.

    1986-01-01

    Values of 169 Yb-DTPA clearance (C DTPA ) calculated after a single injection were compared in 26 recipients of kidneys with renal clearance of inulin (C in ), polyfructosan S (C pf ) and creatinine (C cr ). In 21 patients the examinations were made simultaneously, in 5 patients C DTPA was measured within a short interval after the examination of renal clearance. The mean C DTPA values did not significantly differ from C cr but were significantly higher (p in and C pf (by 33% on average). Investigation of changes in C DTPA as compared with C in and C pf showed no significant difference in glomerular filtration (GF). This was measured using inulin and polyfructosan. The results showed that the differing molecular weight of inulin and polyfructosan S had no detectable effect on the GF of kidney recipients. The plasma clearance of 169 Yb-DTPA similarly to C cr overestimates the GF measured by inulin and polyfructosan clearance. (author)

  4. Lithium clearance in chronic nephropathy

    DEFF Research Database (Denmark)

    Kamper, A L; Holstein-Rathlou, N H; Leyssac, P P

    1989-01-01

    1. Lithium clearance measurements were made in 72 patients with chronic nephropathy of different aetiology and moderate to severely reduced renal function. 2. Lithium clearance was strictly correlated with glomerular filtration rate, and there was no suggestion of distal tubular reabsorption...... of lithium or influence of osmotic diuresis. 3. Fractional reabsorption of lithium was reduced in most patients with glomerular filtration rates below 25 ml/min. 4. Calculated fractional distal reabsorption of sodium was reduced in most patients with glomerular filtration rates below 50 ml/min. 5. Lithium...... that lithium clearance may be a measure of the delivery of sodium and water from the renal proximal tubule. With this assumption it was found that adjustment of the sodium excretion in chronic nephropathy initially takes place in the distal parts of the nephron (loop of Henle, distal tubule and collecting duct...

  5. Refrigeration system with clearance seals

    International Nuclear Information System (INIS)

    Holland, N. J.

    1985-01-01

    In a refrigeration system such as a split Stirling system, fluid seals associated with the reciprocating displacer are virtually dragless clearance seals. Movement of the displacer relative to the pressure variations in the working volume of gas is retarded by a discrete braking element. Because it is not necessary that the brake providing any sealing action, the brake can be designed for greater durability and less dependence on ambient and operating temperatures. Similarly, the clearance seal can be formed of elements having low thermal expansion such that the seal is not temperature dependent. In the primary embodiments the braking element is a split friction brake

  6. Inherited Disorders of Bilirubin Clearance

    Science.gov (United States)

    Memon, Naureen; Weinberger, Barry I; Hegyi, Thomas; Aleksunes, Lauren M

    2016-01-01

    Inherited disorders of hyperbilirubinemia may be caused by increased bilirubin production or decreased bilirubin clearance. Reduced hepatic bilirubin clearance can be due to defective 1) unconjugated bilirubin uptake and intrahepatic storage, 2) conjugation of glucuronic acid to bilirubin (e.g. Gilbert syndrome, Crigler-Najjar syndrome, Lucey-Driscoll syndrome, breast milk jaundice), 3) bilirubin excretion into bile (Dubin-Johnson syndrome), or 4) conjugated bilirubin re-uptake (Rotor syndrome). In this review, the molecular mechanisms and clinical manifestations of these conditions are described, as well as current approaches to diagnosis and therapy. PMID:26595536

  7. Determination of Glomerular Filtration Rate with {sup 51}Cr, {sup 58}Co, {sup 114m}In, {sup 115m}In and {sup 169}Yb- Labelled EDTA and DTPA Complexes

    Energy Technology Data Exchange (ETDEWEB)

    Molnar, Gy.; Pal, I.; Stuetzel, M.; Jaky, L. [Third Department of Medicine, University Medical School and Institute of Isotopes of the Hungarian Academy of Sciences, Budapest (Hungary)

    1971-02-15

    Some metal complexes are suitable for determination of the glomerular filtration rate (GFR). A series of labelled EDTA and DTPA complexes have been produced during the last two years by the Isotope Institute of the Hungarian Academy of Sciences. The common property of EDTA and DTPA complexes is their great stability, which is a major advantage over the iodinated compounds. We have demonstrated that none of the complexes used by us combine with plasma proteins or penetrate into the red blood cells. There is evidence that EDTA and DTPA leave the body exclusively by way of glomerular filtration. The results of more than 600 cases are presented. {sup 169}Yb EDTA was used in 315, {sup 51}Cr EDTA in 126, {sup 114m}In EDTA in 83, {sup 58}Co DTPA in 72 and {sup 115m}In EDTA in 28 cases for determination of GFR. The injected activity was 0.3 -4.0 {mu}Ci/kg body weight. In most cases the result has been compared with the 24-h endogenous creatine clearance, and in 50 cases with inulin clearance also. In general the single-shot method was used. Blood samples were taken about the first and the second hour after injection of the isotope. A formula is given for calculating GFR. In a few cases we administered the isotope in the same way as inulin (priming dose and constant plasma concentration sustained by an infusion pump). Our results show that the single-shot method is a very suitable one in routine clinical practice either in states of normal or reduced kidney function. Using the single-shot method for GFR determination is especially important in those cases where the collection of urine is impossible without using a catheter, which always entails the risk of infection. Results are reliable even in disorders of the urinary tract. During or after the procedure no side effects could be observed. (author)

  8. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  9. Escaping the correction for body surface area when calculating glomerular filtration rate in children

    International Nuclear Information System (INIS)

    Piepsz, Amy; Tondeur, Marianne; Ham, Hamphrey

    2008-01-01

    51 Cr ethylene diamine tetraacetic acid ( 51 Cr EDTA) clearance is nowadays considered as an accurate and reproducible method for measuring glomerular filtration rate (GFR) in children. Normal values in function of age, corrected for body surface area, have been recently updated. However, much criticism has been expressed about the validity of body surface area correction. The aim of the present paper was to present the normal GFR values, not corrected for body surface area, with the associated percentile curves. For that purpose, the same patients as in the previous paper were selected, namely those with no recent urinary tract infection, having a normal left to right 99m Tc MAG3 uptake ratio and a normal kidney morphology on the early parenchymal images. A single blood sample method was used for 51 Cr EDTA clearance measurement. Clearance values, not corrected for body surface area, increased progressively up to the adolescence. The percentile curves were determined and allow, for a single patient, to estimate accurately the level of non-corrected clearance and the evolution with time, whatever the age. (orig.)

  10. Escaping the correction for body surface area when calculating glomerular filtration rate in children

    Energy Technology Data Exchange (ETDEWEB)

    Piepsz, Amy; Tondeur, Marianne [CHU St. Pierre, Department of Radioisotopes, Brussels (Belgium); Ham, Hamphrey [University Hospital Ghent, Department of Nuclear Medicine, Ghent (Belgium)

    2008-09-15

    {sup 51}Cr ethylene diamine tetraacetic acid ({sup 51}Cr EDTA) clearance is nowadays considered as an accurate and reproducible method for measuring glomerular filtration rate (GFR) in children. Normal values in function of age, corrected for body surface area, have been recently updated. However, much criticism has been expressed about the validity of body surface area correction. The aim of the present paper was to present the normal GFR values, not corrected for body surface area, with the associated percentile curves. For that purpose, the same patients as in the previous paper were selected, namely those with no recent urinary tract infection, having a normal left to right {sup 99m}Tc MAG3 uptake ratio and a normal kidney morphology on the early parenchymal images. A single blood sample method was used for {sup 51}Cr EDTA clearance measurement. Clearance values, not corrected for body surface area, increased progressively up to the adolescence. The percentile curves were determined and allow, for a single patient, to estimate accurately the level of non-corrected clearance and the evolution with time, whatever the age. (orig.)

  11. Effect of prior immobilization on muscular glucose clearance in resting and running rats

    International Nuclear Information System (INIS)

    Vissing, J.; Ohkuwa, Tetsuo; Ploug, T.; Galbo, H.

    1988-01-01

    In vitro studies have shown that prior disuse impairs the glucose clearance of red skeletal muscle because of a developed insensitivity to insulin. We studied whether an impaired glucose clearance is present in vivo in 42-h immobilized muscles of resting rats and, furthermore, whether the exercise-induced increase in glucose clearance of red muscles is affected by prior immobilization. The 2-[ 3 H]deoxy-D-glucose (2DG) bolus injection method was used to determine glucose clearance of individual muscles. At rest, glucose clearance was markedly impaired in rats with previously immobilized red muscles compared with nonimmobilized control rats. During running, glucose clearance did not differ between muscles in previously immobilized and control rats. Insulin levels were always similar in the two groups and decreased during exercise. Intracellular nonphosphorylated 2DG was present in tissues with high glucose clearances. In conclusion, 42 h of immobilization markedly impairs glucose clearance of resting red muscle fibers in vivo. Apparently, physical inactivity in particular affects steps involved in insulin-mediated action that are not part of contraction-induced glucose uptake and metabolism. Presence of intracellular 2DG shows that separate determination of phosphorylated 2DG is necessary for accurate estimates of glucose metabolism and that accumulation of phosphorylated 2DG does not accurately reflect glucose transport

  12. Comparison of measurements of plasma clearance of Mebrofenine and of indocyanine green

    International Nuclear Information System (INIS)

    Maurel, G.; Coutris, G.; Vaubourdolle, M.; Attal, P.; Patureau, R.; Tabsoba, Th.; Mensch, B.; Askienazy, Pr.S.

    1997-01-01

    The importance of clearance measurements in evaluating renal or hepatic function needs not further demonstration. The isotopic methods were proved in renal exploration but their utilization in exploration of hepato-biliary function needs to be evaluated. In this work we have compared the measurement of plasma clearance by Mebrofenine, a radiopharmaceutical of specifically hepatic elimination, with the reference method, the clearance of indocyanine green. On the basis of scintigraphic data from 23 patients who benefited by a hepato-biliary exploration by Mebrofenine- 99m Tc for pre-surgery account and surveillance, we have determined the plasma clearance of this radiopharmaceutical. The method makes use of the curve of normalized cardiac activity by a blood sampling, taken 60 minutes after injection. The measurement of the clearance of indocyanine green was effected within a delay inferior to 1 month from the moment of biliary scintigraphy. The average clearance of Mebrofenine- 99m Tc is of 553 ml/min for 1.73 m 2 of corporal surface (typical interval is 374 ml/min), the value of indocyanine green is of 450 ml/min (typical interval is 229 ml/min). The two measurements of clearance are correlated (p = 0.05). In conclusion, the measurement of clearance by Mebrofenine- 99m appears to be adapted to the evaluation of hepato-biliary function

  13. Relationship between silicon concentration and creatinine clearance

    International Nuclear Information System (INIS)

    Miura, Y.; Nakai, K.; Itoh, C.; Horikiri, J.; Sera, K.; Sato, M.

    1998-01-01

    Silicon levels in dialysis patients are markedly increasing. Using PIXE we determined the relationship between silicon concentration and creatinine clearance in 30 samples. Urine silicon concentration were significantly correlated to creatinine clearance (p<0.001). And also serum silicon concentration were significantly correlated to creatinine clearance (p<0.0001). (author)

  14. Comparison of the endogenous creatinine clearance, the creatinin clearance calculated without urine collection and the isotope clearance

    International Nuclear Information System (INIS)

    Mohacsi, Gabor; Lang, Jenoe; Csernay, Laszlo; Sonkodi, Sandor; Orvostudomanyi Egyetem, Szeged

    1987-01-01

    Observations are reported relating to the endogenous creatinine clearance, the Tc-99m-EDTA-complex clearance and the creatinine clearance estimated via a selected mathematical formula, with special regard to the problems of renal insufficiency and the nephrotic syndrome. The activity applied was in the range of 3.7-7.4 MBq. It was observed that measurement of the isotope clearance can also be applied to determine the endogeneous creatinine clearance in otherwise less suitable patients. A reliable result is obtained even if the renal function is restricted, but the accuracy of the method may be reduced in nephrotic syndrome cases. (author) 24 refs

  15. Diesel Engine Valve Clearance Detection Using Acoustic Emission

    Directory of Open Access Journals (Sweden)

    Fathi Elamin

    2010-01-01

    Full Text Available This paper investigated, using experimental method, the suitability of acoustic emission (AE technique for the condition monitoring of diesel engine valve faults. The clearance fault was adjusted experimentally in an exhaust valve and successfully detected and diagnosed in a Ford FSD 425 four-cylinder, four-stroke, in-line OHV, direct injection diesel engine. The effect of faulty exhaust valve clearance on engine performance was monitored and the difference between the healthy and faulty engine was observed from the recorded AE signals. The measured results from this technique show that using only time domain and frequency domain analysis of acoustic emission signals can give a superior measure of engine condition. This concludes that acoustic emission is a powerful and reliable method of detection and diagnosis of the faults in diesel engines and this is considered to be a unique approach to condition monitoring of valve performance.

  16. Impairment of paravascular clearance pathways in the aging brain.

    Science.gov (United States)

    Kress, Benjamin T; Iliff, Jeffrey J; Xia, Maosheng; Wang, Minghuan; Wei, Helen S; Zeppenfeld, Douglas; Xie, Lulu; Kang, Hongyi; Xu, Qiwu; Liew, Jason A; Plog, Benjamin A; Ding, Fengfei; Deane, Rashid; Nedergaard, Maiken

    2014-12-01

    In the brain, protein waste removal is partly performed by paravascular pathways that facilitate convective exchange of water and soluble contents between cerebrospinal fluid (CSF) and interstitial fluid (ISF). Several lines of evidence suggest that bulk flow drainage via the glymphatic system is driven by cerebrovascular pulsation, and is dependent on astroglial water channels that line paravascular CSF pathways. The objective of this study was to evaluate whether the efficiency of CSF-ISF exchange and interstitial solute clearance is impaired in the aging brain. CSF-ISF exchange was evaluated by in vivo and ex vivo fluorescence microscopy and interstitial solute clearance was evaluated by radiotracer clearance assays in young (2-3 months), middle-aged (10-12 months), and old (18-20 months) wild-type mice. The relationship between age-related changes in the expression of the astrocytic water channel aquaporin-4 (AQP4) and changes in glymphatic pathway function was evaluated by immunofluorescence. Advancing age was associated with a dramatic decline in the efficiency of exchange between the subarachnoid CSF and the brain parenchyma. Relative to the young, clearance of intraparenchymally injected amyloid-β was impaired by 40% in the old mice. A 27% reduction in the vessel wall pulsatility of intracortical arterioles and widespread loss of perivascular AQP4 polarization along the penetrating arteries accompanied the decline in CSF-ISF exchange. We propose that impaired glymphatic clearance contributes to cognitive decline among the elderly and may represent a novel therapeutic target for the treatment of neurodegenerative diseases associated with accumulation of misfolded protein aggregates. © 2014 American Neurological Association.

  17. Development of the clearance level verification evaluation system. 2. Construction of the clearance data management system

    International Nuclear Information System (INIS)

    Kubota, Shintaro; Usui, Hideo; Kawagoshi, Hiroshi

    2014-06-01

    Clearance is defined as the removal of radioactive materials or radioactive objects within authorized practices from any further regulatory control by the regulatory body. In Japan, clearance level and a procedure for its verification has been introduced under the Laws and Regulations, and solid clearance wastes inspected by the national authority can be handled and recycled as normal wastes. The most prevalent type of wastes have generated from the dismantling of nuclear facilities, so the Japan Atomic Energy Agency (JAEA) has been developing the Clearance Level Verification Evaluation System (CLEVES) as a convenient tool. The Clearance Data Management System (CDMS), which is a part of CLEVES, has been developed to support measurement, evaluation, making and recording documents with clearance level verification. In addition, validation of the evaluation result of the CDMS was carried out by inputting the data of actual clearance activities in the JAEA. Clearance level verification is easily applied by using the CDMS for the clearance activities. (author)

  18. Granisetron Injection

    Science.gov (United States)

    Granisetron immediate-release injection is used to prevent nausea and vomiting caused by cancer chemotherapy and to ... nausea and vomiting that may occur after surgery. Granisetron extended-release (long-acting) injection is used with ...

  19. Edaravone Injection

    Science.gov (United States)

    Edaravone injection is used to treat amyotrophic lateral sclerosis (ALS, Lou Gehrig's disease; a condition in which ... die, causing the muscles to shrink and weaken). Edaravone injection is in a class of medications called ...

  20. Meropenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria that cause infection.Antibiotics such as meropenem injection will not work for colds, flu, or other viral infections. Taking ...

  1. Chloramphenicol Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by stopping the growth of bacteria..Antibiotics such as chloramphenicol injection will not work for colds, flu, or other viral infections. Taking ...

  2. Colistimethate Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria.Antibiotics such as colistimethate injection will not work for colds, flu, or other viral infections. Using ...

  3. Defibrotide Injection

    Science.gov (United States)

    Defibrotide injection is used to treat adults and children with hepatic veno-occlusive disease (VOD; blocked blood ... the body and then returned to the body). Defibrotide injection is in a class of medications called ...

  4. Nalbuphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using nalbuphine injection, you may experience withdrawal symptoms including restlessness; teary eyes; runny nose; yawning; ...

  5. Pleural liquid clearance rate measured in awake sheep by the volume of dilution method

    International Nuclear Information System (INIS)

    Broaddus, V.C.; Wiener-Kronish, J.P.; Berthiaume, Y.; Staub, N.C.

    1986-01-01

    The authors reported 24h clearance of mock pleural effusions measured terminally in sheep. To measure effusion volume at different times in the same sheep, they injected 111 In-transferrin and measured its dilution. In 5 sheep with effusions of known sizes, the method was accurate to +/-10%. In 5 awake sheep, the authors injected 10 ml/kg of a 1% protein solution via a non-penetrating rib capsule. At 6h, the authors measured the volume by the dilution method and at 24h by direct recovery. The clearance rate in each animal was constant at 2.9-6.0%/h (average 4.8 +/- 1.3%/h). This new method gives a reliable two point clearance rate and requires fewer animals

  6. Effects of dipyridamole-induced vasodilation on myocardial uptake and clearance kinetics of thallium-201

    International Nuclear Information System (INIS)

    Beller, G.A.; Holzgrefe, H.H.; Watson, D.D.

    1983-01-01

    Myocardial thallium-201 (201Tl) uptake and clearance after intravenous administration of dipyridamole (150 micrograms/kg) were determined in 12 open-chest anesthetized dogs with a partial coronary artery stenosis. 201Tl (1.5 mCi) was injected intravenously and myocardial biopsy specimens were obtained 10 min, 60 min, and 2 hr after injection. Serial changes in 201Tl activity in the normal zone and in the zone of partial stenosis were correlated with microsphere-determined regional blood flow and distal coronary pressure. Another nine dogs with equivalent stenosis not given dipyridamole before 201Tl served as controls. Data indicate that dipyridamole-induced vasodilation in the presence of a partial stenosis results in diminished uptake and delayed clearance compared with increased uptake and more rapid clearance in normally perfused myocardium producing an initial 201Tl defect with delayed redistribution

  7. The role of neutrophilic mediators in acute inflammation of the gut

    International Nuclear Information System (INIS)

    Ritter, C. von.

    1988-01-01

    Activation of granulocytes within the lamina propria by luminally derived bacterial products may represent an important mechanism in the pathogenesis of inflammatory bowel disease. One objective of this thesis was to determine the effects of luminal perfusion with N-formyl-methionyl-leucyl-phenylalanine (FMLP), a bacterial product that attracts and activates granulocytes, on mucosal permeability in different regions of the rat small intestine and colon. Mucosal permeability was measured using the blood-to-lumen clearance of 51 Cr-EDTA during luminal perfusion with FMLP dissolved in Tyrode's solution. Of the bowel segments studied, mucosal permeability was significantly increased only in the distal 10 cm of the ileum. In order to define the role of neutrophilic oxidants in FMLP-induced ileitis, we evaluated the protective effect of several free radical scavengers and antioxidant enzymes. Pretreatment with the either superoxide dismutase or catalase had no effect on the FMLP-induced increase in mucosal permeability. However, treatment with either Mn-desferrioxamine, PZ51, desferrioxamine, or dimethylsulfoxide significantly attenuated FMLP-induced mucosal damage. Non-oxidative toxins released from activated neutrophil may be another mechanism by which FMLP increases mucosal permeability. In order to investigate the role of neutrophilic proteases in FMLP-induced ileitis, the effects of the nonspecific protease inhibitor soybean trypsin inhibitor, and the elastase inhibitors MeOSuc-Ala-Ala-Pro-Val-CH 2 Cl(MAAPV) and Eglin C on the FMLP-induced increases in 51 Cr-EDTA clearance were determined

  8. 32 CFR 154.16 - Security clearance.

    Science.gov (United States)

    2010-07-01

    ... part. The Director, Washington Headquarters Services (WHS) will initiate the required investigation... clearance, as appropriate. The Assistant Secretary of Defense (Legislative Affairs) will be notified by WHS...

  9. Hepatic macrophage complement receptor clearance function following injury.

    Science.gov (United States)

    Cuddy, B G; Loegering, D J; Blumenstock, F A; Shah, D M

    1986-03-01

    Previous work has demonstrated that in vivo hepatic macrophage complement receptor clearance function is depressed following thermal injury. The present study was carried out to determine if complement receptor function depression is associated with other states of depressed host defense. Hepatic complement receptor clearance function was determined from the hepatic uptake of rat erythrocytes coated with antierythrocyte IgM (EIgM) in rats. Receptor function was determined following cannulation of a carotid artery, laparotomy plus enterotomy, hemorrhagic shock, trauma, thermal injury, acute bacteremia, acute endotoxemia, and injection of erythrocyte stroma, gelatinized lipid emulsion, or colloidal carbon. Hepatic uptake of EIgM was depressed following each of these experimental interventions except arterial cannulation. This effect was shown not to be due to a decrease in hepatic blood flow or depletion of complement and was therefore due to a depression in hepatic macrophage complement receptor clearance function. Thus, impairment of hepatic macrophage complement receptor function is associated with several states of depressed host defense.

  10. Roles of crustacean hyperglycaemic hormone in ionic and metabolic homeostasis in the Christmas Island blue crab, Discoplax celeste.

    Science.gov (United States)

    Turner, Lucy M; Webster, Simon G; Morris, Stephen

    2013-04-01

    There is a growing body of evidence implicating the involvement of crustacean hyperglycaemic hormone (CHH) in ionic homeostasis in decapod crustaceans. However, little is known regarding hormonally influenced osmoregulatory processes in terrestrial decapods. As many terrestrial decapods experience opposing seasonal demands upon ionoregulatory physiologies, we reasoned that these would make interesting models in which to study the effect of CHH upon these phenomena. In particular, those (tropical) species that also undergo seasonal migrations might be especially informative, as we know relatively little regarding the nature of CHHs in terrestrial decapods, and hormonally mediated responses to seasonal changes in metabolic demands might also be superimposed or otherwise integrated with those associated with ionic homeostasis. Using Discoplax celeste as a model crab that experiences seasonal extremes in water availability, and exhibits diurnal and migratory activity patterns, we identified two CHHs in the sinus gland. We biochemically characterised (cDNA cloning) one CHH and functionally characterised (in terms of dose-dependent hyperglycaemic responses and glucose-dependent negative feedback loops) both CHHs. Whole-animal in situ branchial chamber (22)NaCl perfusion experiments showed that injection of both CHHs increased gill Na(+) uptake in a seasonally dependent manner, and (51)Cr-EDTA clearance experiments demonstrated that CHH increased urine production by the antennal gland. Seasonal and salinity-dependent differences in haemolymph CHH titre further implicated CHH in osmoregulatory processes. Intriguingly, CHH appeared to have no effect on gill Na(+)/K(+)-ATPase or V-ATPase activity, suggesting unknown mechanisms of this hormone's action on Na(+) transport across gill epithelia.

  11. Individualized dosimetry-based activity reduction of {sup 90}Y-DOTATOC prevents severe and rapid kidney function deterioration from peptide receptor radionuclide therapy

    Energy Technology Data Exchange (ETDEWEB)

    Binnebeek, Sofie van; Baete, Kristof; Vanbilloen, Bert; Terwinghe, Christelle; Mortelmans, Luc [University Hospitals Leuven, Nuclear Medicine, Leuven (Belgium); KU Leuven, Department of Imaging and Pathology, Leuven (Belgium); Koole, Michel [University Medical Centre Groningen, Department of Nuclear Medicine, Groningen (Netherlands); Mottaghy, Felix M. [University Hospital Aachen, Department of Nuclear Medicine, Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, Maastricht (Netherlands); Clement, Paul M. [University Hospitals Leuven, Medical Oncology, Leuven (Belgium); KU Leuven, Laboratory of Experimental Oncology, Leuven (Belgium); Haustermans, Karin [University Hospitals Leuven, Radiation Oncology, Leuven (Belgium); KU Leuven, Department of Oncology, Leuven (Belgium); Cutsem, Eric van; Verslype, Chris [KU Leuven, Department of Oncology, Leuven (Belgium); University Hospitals Leuven, Division of Digestive Oncology, Leuven (Belgium); Verbruggen, Alfons [KU Leuven, Laboratory for Radiopharmacy, Leuven (Belgium); Bogaerts, Kris [KU Leuven, Division of Public Health and Primary Care (I-Biostat), Leuven (Belgium); Deroose, Christophe M. [University Hospitals Leuven, Nuclear Medicine, Leuven (Belgium); KU Leuven, Department of Imaging and Pathology, Leuven (Belgium); UZ Leuven, Nuclear Medicine, Leuven (Belgium)

    2014-06-15

    Assessment of kidney function evolution after {sup 90}Y-DOTATOC peptide receptor radionuclide therapy (PRRT) with capped activity administration based on a 37-Gy threshold of biological effective dose (BED) to the kidney. In a prospective phase II study, patients with metastasized neuroendocrine tumours were evaluated for therapy using 185 MBq {sup 111}In-pentetreotide with amino acid coinfusion. Planar whole-body images were acquired at four time-points after injection and kidney volumes were measured using CT/MRI. BED to the kidneys was estimated using an extended BED formula and biexponential renal clearance. Based on published BED dose-toxicity relationships, we allowed a maximal kidney BED of 37 Gy; if the calculated BED exceeded 37 Gy, treatment activity was reduced accordingly. Kidney function was assessed at baseline and at 18 months, predominantly using {sup 51}Cr-EDTA. The rate of renal function decline was expressed as annual glomerular filtration rate loss (aGFRL). Only 22 of 50 patients reached the 18-months time-point, with most missing patients having died due to disease progression. In the 22 patients who reached 18 months, no rapid kidney function deterioration was observed over the 18 months, aGFRL >33 % was not seen, and only three patients showed an increase of one toxicity grade and one patient an increase of two grades. No significant correlations between kidney volume (p = 0.35), baseline GFR (p = 0.18), risk factors for renal function loss (p = 0.74) and aGFRL were observed. Among the 28 patients who did not reach 18 months, one developed grade 4 kidney toxicity at 15 months after PRRT. Prospective dosimetry using a 37 Gy BED as the threshold for kidney toxicity is a good guide for {sup 90}Y-DOTATOC PRRT and is associated with a low risk of rapid renal function deterioration and evolution to severe nephrotoxicity. (orig.)

  12. Scan Manifestation and Trace-Dose Radiogold Clearance Rates in Obstructive Jaundice

    International Nuclear Information System (INIS)

    Kim, Dong Jip; Bahk, Yong Whee; Shinn, Kyung Sub

    1969-01-01

    The present study has been undertaken to analyze scan manifestation in obstructive jaundice. Scan changes were correlated with the duration of jaundice. In addition, clearance rates of trace dose of colloidal radiogold were assessed in each case. The materials were consisted of 19 cases with surgically and/or histopathologically verified obstructive jaundice from various causes including common duct stone, empyema of the gall bladder and carcinoma of the pancreas head etc. Blood clearance rates of colloidal 198 Au were determined after the injection of 8 uCi by simple geometrical drawing of recorded strip charts. Scan was performed following additional injection of the sam radiogold. In 16 out of 19 cases, the scan rather typical 'arborifrom' mottlings around the porta hepatis. The intensity and appearance of such mottlings on the scan was related with the duration of jaundice and level of serum bilirubin and alkaline phosphatase. The blood clearance rates remained to be within normal range in 74 percent of the patients. In the remaining 26 percent, clearance rate ranged between 4.1 and 6 minutes. It is concluded that the association of 'arboriform' mottlings and normal or mildly delayed clearance rates in the patients with jaundice is characteristic of obstructive change in the biliary system.

  13. Scan Manifestation and Trace-Dose Radiogold Clearance Rates in Obstructive Jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Jip; Bahk, Yong Whee; Shinn, Kyung Sub [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1969-09-15

    The present study has been undertaken to analyze scan manifestation in obstructive jaundice. Scan changes were correlated with the duration of jaundice. In addition, clearance rates of trace dose of colloidal radiogold were assessed in each case. The materials were consisted of 19 cases with surgically and/or histopathologically verified obstructive jaundice from various causes including common duct stone, empyema of the gall bladder and carcinoma of the pancreas head etc. Blood clearance rates of colloidal {sup 198}Au were determined after the injection of 8 uCi by simple geometrical drawing of recorded strip charts. Scan was performed following additional injection of the sam radiogold. In 16 out of 19 cases, the scan rather typical 'arborifrom' mottlings around the porta hepatis. The intensity and appearance of such mottlings on the scan was related with the duration of jaundice and level of serum bilirubin and alkaline phosphatase. The blood clearance rates remained to be within normal range in 74 percent of the patients. In the remaining 26 percent, clearance rate ranged between 4.1 and 6 minutes. It is concluded that the association of 'arboriform' mottlings and normal or mildly delayed clearance rates in the patients with jaundice is characteristic of obstructive change in the biliary system.

  14. 2015 Annual Report on Security Clearance Determinations

    Science.gov (United States)

    2016-06-28

    only have delegated investigative authority over their civilian employee population and therefore, can only report the overall timeliness for that...completed or pending security clearance determinations for government employees and contractors during the preceding fiscal year that have taken longer...Clearance Determinations to Congress. The IAA directs this report to include the number of United States Government (USG) employees who held a

  15. Green technology; only Forest Clearance is needed

    Indian Academy of Sciences (India)

    First page Back Continue Last page Graphics. How was Forest Clearance granted before the procedures for constitution of ESZ was completed? How was Forest Clearance granted before the procedures for constitution of ESZ was completed? How was land in Murmurwadi still under litigation made available? How was ...

  16. Effect of glucose-insulin-potassium infusion on thallium myocardial clearance

    International Nuclear Information System (INIS)

    Wilson, R.A.; Okada, R.D.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Factors influencing the rate of 201 Tl clearance from the myocardium have not been clearly defined. This study determined the effect of an intravenous infusion of glucose-insulin-potassium (GIK) on the net 201 Tl clearance rates from myocardium with and without initial 201 Tl loading. Anesthetized open-chest dogs underwent 5 min of left anterior descending coronary artery occlusion and intravenous 201 Tl was injected and the occlusion released 5 min later. Thirty minutes after 201 Tl injection, 30 ml of either GIK (nine dogs) or saline (five dogs) was infused intravenously. The clearance rates of 201 Tl from the anterior wall (without initial 201 Tl loading) and from the posterior wall (with initial 201 Tl loading) were monitored with miniaturized cadmium telluride detectors placed on the myocardium. Calculation of net myocardial clearance rates was performed by linear regression analysis from serial 1 min counts. Compared with saline infusion, GIK increased the net clearance of 201 Tl from both myocardial regions with and without initial loading. The most marked change induced by GIK infusion was in the myocardial region without initial 201 Tl loading; a net increase in 201 Tl activity (72 +/- 42 cpm/30 min) was converted into a net loss (-594 +/- 228 cpm/30 min). There was no significant change in 201 Tl clearance after the saline infusion. Heart rate, aortic and left atrial pressure, sonomicrometer-measured transmural myocardial wall thickness, microsphere-determined myocardial blood flow, and blood glucose and potassium concentrations did not change significantly during GIK or saline infusions. Thus, GIK infusion appears to increase net 201 Tl clearance from myocardial zones with and without initial 201 Tl loading

  17. Effect of prior immobilization on muscular glucose clearance in resting and running rats

    DEFF Research Database (Denmark)

    Vissing, J; Ohkuwa, T; Ploug, Thorkil

    1988-01-01

    with nonimmobilized control rats (red gastrocnemius 0.46 +/- 0.02 vs. 0.99 +/- 0.08 and soleus 1.10 +/- 0.30 vs. 3.97 +/- 0.54 ml.min-1.100 g-1, P less than 0.005). During running (18 m/min), glucose clearance did not differ between muscles in previously immobilized and control rats. Insulin levels were always......In vitro studies have shown that prior disuse impairs the glucose clearance of red skeletal muscle because of a developed insensitivity to insulin. We studied whether an impaired glucose clearance is present in vivo in 42-h immobilized muscles of resting rats and, furthermore, whether the exercise......-induced increase in glucose clearance of red muscles is affected by prior immobilization. The 2-[3H]deoxy-D-glucose (2DG) bolus injection method was used to determine glucose clearance of individual muscles. At rest, glucose clearance was markedly impaired in rats with previously immobilized red muscles compared...

  18. Clearance of materials from accelerator facilities

    Directory of Open Access Journals (Sweden)

    Rokni Sayed H.

    2017-01-01

    Full Text Available A new Technical Standard that supports the clearance of materials and equipment (personal property from U.S. Department of Energy (DOE accelerator facilities has been developed. The Standard focuses on personal property that has the potential to be radiologically impacted by accelerator operations. It addresses material clearance programs and protocols for off-site releases without restriction on use. Common metals with potential volumetric activation are of main interest with technical bases provided in Appendices of the Standard. The clearance protocols in the Standard include three elements: 1 clearance criteria, 2 process knowledge, and 3 measurement methods. This paper presents the technical aspects of the new Standard, discusses operational experience gained in clearance of materials and equipment from several accelerator facilities at SLAC and examples as to how this Standard can be applied to benefit the entirety of the DOE Accelerator Complex.

  19. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure ...

  20. Hydromorphone Injection

    Science.gov (United States)

    ... anyone else to use your medication. Store hydromorphone injection in a safe place so that no one else can use it accidentally or on purpose. Keep track of how much medication is left so ... with hydromorphone injection may increase the risk that you will develop ...

  1. Ketorolac Injection

    Science.gov (United States)

    ... an older adult, you should know that ketorolac injection is not as safe as other medications that can be used to treat your condition. Your doctor may choose to prescribe a different medication ... to ketorolac injection.Your doctor or pharmacist will give you the ...

  2. Paclitaxel Injection

    Science.gov (United States)

    (pak'' li tax' el)Paclitaxel injection must be given in a hospital or medical facility under the supervision of a doctor who is experienced in giving chemotherapy medications for cancer.Paclitaxel injection may cause a large decrease in the number of white blood cells (a type of blood cell ...

  3. Technetium-99m mercaptoacetyltriglycine clearance values in children with minimal renal disease: can a normal range be determined?

    International Nuclear Information System (INIS)

    Meyer, G.; Hahn, K.; Piepsz, A.; Kolinska, J.; Lepej, J.; Sixt, R.

    1998-01-01

    Use of technetium-99m labelled mercaptoacetyltriglycine ( 99m Tc-MAG3) simplifies and improves the quantification of renal clearance in children by virtue of its permanent availability, good imaging properties and low radiation exposure. Due to the lack of reference values for 99m Tc-MAG3 clearance in children, the Paediatric Task Group of the EANM initiated a multicentre study to evaluate 99m Tc-MAG3 clearance values in children with minimal renal disease. One hundred and twenty-five children aged between 12 months and 17 years, classified as renally healthy using defined diagnostic criteria, were included in the study. 99m Tc-MAG3 clearance was calculated using an algorithm on the basis of a single blood sample taken at any time between 30 and 40 min after tracer injection. In addition, the absolute 99m -Tc-MAG3 clearance values were normalized to body surface area. For further evaluation the children were classified into several groups according to age. There was a continuous increase in non-corrected 99m Tc-MAG3 clearance values from the age of 1 year up to the age of 17 years (mean value 8 years: 208±66 ml/min). Normal clearance values for adults were achieved by the age of 8 years. Analysis of the relationship between non-corrected clearance and age yielded a correlation coefficient of r=0.7. When these absolute clearance values were normalized to body surface area, we found nearly constant clearance values for all age groups, with a mean clearance value of 315±114 ml/min x 1.73 m 2 . The correlation coefficient for the relationship between normalized clearance and age was r=0.28. In conclusion, the clearance of 99m Tc-MAG3 increases continuously throughout childhood into adolescence due to the maturation and growth of the kidney. After normalization of the absolute clearance to body surface area, no correlation between clearance and age could be proven. (orig.)

  4. 51Cr-ethylenediaminetetraacetic acid absorption test

    International Nuclear Information System (INIS)

    Aabakken, L.

    1989-01-01

    The 51 Cr-ethylenediaminetetraacetic acid (EDTA) absorption test was evaluated in 83 healthy, male volunteers. Base-line 24 h excretion after peroral administration ranged from 0.88% to 7.96%, with a higher median absorption than reported by most authors (2.45%). However, the reproducibility and stability of the method and the reproducibility of the results were satisfactory. Urinary excretion after intraduodenal installation (n=18) was comparable to that seen after peroral test dose administration, indicating a limited significance of gastric 51 Cr-EDTA absorption under normal conditions. In 16 subjects a single intake of alcohol immediately before the test gave a modest and short-lasting increase in 51 Cr-EDTA absorption. No correlation was seen to body mass index, creatinine clearance, urinary volume, or small-bowel transit time, possibly reducing the number of confounding factors in the evaluation of absorption data. A small but significant negative correlation was, however, found to body surface area and age

  5. Temozolomide Injection

    Science.gov (United States)

    ... balance or coordination fainting dizziness hair loss insomnia memory problems pain, itching, swelling, or redness in the place where the medication was injected changes in vision Some side effects can be serious. If you ...

  6. Buprenorphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opiate partial agonists. It works to prevent withdrawal symptoms ... help. If the victim has collapsed, had a seizure, has trouble breathing, or can't be awakened, ...

  7. Risperidone Injection

    Science.gov (United States)

    ... release (long-acting) injection is used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  8. Haloperidol Injection

    Science.gov (United States)

    ... haloperidol extended-release injection are used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  9. Omalizumab Injection

    Science.gov (United States)

    ... injection is used to decrease the number of asthma attacks (sudden episodes of wheezing, shortness of breath, and ... about how to treat symptoms of a sudden asthma attack. If your asthma symptoms get worse or if ...

  10. Injection Tests

    CERN Document Server

    Kain, V

    2009-01-01

    The success of the start-up of the LHC on 10th of September was in part due to the preparation without beam and injection tests in 2008. The injection tests allowed debugging and improvement in appropriate portions to allow safe, efficient and state-of-the-art commissioning later on. The usefulness of such an approach for a successful start-up becomes obvious when looking at the problems we encountered before and during the injection tests and could solve during this period. The outline of the preparation and highlights of the different injection tests will be presented and the excellent performance of many tools discussed. A list of shortcomings will follow, leading to some planning for the preparation of the run in 2009.

  11. Cefotaxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotaxime injection will not work for colds, flu, or other viral infections. Using ...

  12. Cefuroxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefuroxime injection will not work for colds, flu, or other viral infections. Using ...

  13. Doripenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as doripenem injection will not work for colds, flu, or other viral infections. Taking ...

  14. Daptomycin Injection

    Science.gov (United States)

    ... in a class of medications called cyclic lipopeptide antibiotics. It works by killing bacteria.Antibiotics such as daptomycin injection will not work for treating colds, flu, or other viral infections. ...

  15. Ceftaroline Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftaroline injection will not work for colds, flu, or other viral infections. Using ...

  16. Aztreonam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as aztreonam injection will not work for colds, flu, or other viral infections. Taking ...

  17. Cefazolin Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefazolin injection will not work for colds, flu, or other viral infections. Taking ...

  18. Ceftazidime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftazidime injection will not work for colds, flu, or other viral infections. Using ...

  19. Cefotetan Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotetan injection will not work for colds, flu, or other viral infections. Using ...

  20. Cefoxitin Injection

    Science.gov (United States)

    ... is in a class of medications called cephamycin antibiotics. It works by killing bacteria.Antibiotics such as cefoxitin injection will not work for colds, flu, or other viral infections. Taking ...

  1. Tigecycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infection.Antibiotics such as tigecycline injection will not work for colds, flu, or other viral infections. Using ...

  2. Ertapenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as ertapenem injection will not work for colds, flu, or other viral infections. Taking ...

  3. Ceftriaxone Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftriaxone injection will not work for colds, flu, or other viral infections.Using ...

  4. Cefepime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefepime injection will not work for colds, flu, or other viral infections. Using ...

  5. Telavancin Injection

    Science.gov (United States)

    ... is in a class of medications called lipoglycopeptide antibiotics. It works by killing bacteria that cause infection.Antibiotics such as telavancin injection will not work for colds, flu, or other viral infections. Using ...

  6. Doxycycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infections.Antibiotics such as doxycycline injection will not work for colds, flu, or other viral infections. Taking ...

  7. Vancomycin Injection

    Science.gov (United States)

    ... is in a class of medications called glycopeptide antibiotics. It works by killing bacteria that cause infections.Antibiotics such as vancomycin injection will not work for colds, flu, or other viral infections. Taking ...

  8. Octreotide Injection

    Science.gov (United States)

    ... carton and protect it from light. Dispose of multi-dose vials of the immediate-release injection 14 ... and immediately place the medication in a safe location – one that is up and away and out ...

  9. Moxifloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using moxifloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  10. Delafloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using delafloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  11. Levofloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using levofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  12. Ciprofloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using ciprofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  13. Alirocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibodies. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Alirocumab injection may ...

  14. Evolocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibody. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Evolocumab injection may ...

  15. Acyclovir Injection

    Science.gov (United States)

    ... It is also used to treat first-time genital herpes outbreaks (a herpes virus infection that causes sores ... in the body. Acyclovir injection will not cure genital herpes and may not stop the spread of genital ...

  16. Butorphanol Injection

    Science.gov (United States)

    ... Butorphanol is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using butorphanol injection, you may experience withdrawal symptoms such as nervousness, agitation, shakiness, diarrhea, chills, ...

  17. Kinetics of heat damage autologous red blood cells. Mechanism of clearance from blood

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M.; Ryan, P.F.J.; Klonizakis, I.; Elkon, K.B.; Lewis, S.M.; Hughes, G.R.V.; Lavender, J.P. (Hammersmith Hospital, London (UK))

    1982-01-01

    The kinetics of radiolabelled heat damage red cell (HDRBC) distribution have been studied in humans using a gamma camera, and compared with the kinetics of other blood cells. Liver uptake of /sup 111/In labelled HDRBC was completed within about 10 min of injection; splenic uptake was biphasic with a half time of about 5 min over the first 20 min in following injection, and a later half time much longer than this. Activity initially present in the lung fields cleared within 24 h. The rate constant of liver uptake of sup(99m)Tc labelled HDRBC and of /sup 111/In labelled platelets were very similar; the rate constants of splenic uptake of these 2 particles were also very similar up to about 20 min following injection when the splenic platelet levels became constant and the HDRBC level continued to slowly rise. Splenic uptake and blood clearance of red cells coated with IgG (IgG-RBC), in contrast to HDRBC, were monoexponential. It was concluded that: (1) the blood clearance of HDRBC was due to pooling within, and to irreversible extraction by, the spleen; (2) liver uptake of HDRBC, which was irreversible, was completed within 10 min of injection; (3) IgG-RBC clearance was due to irreversible extraction by the spleen; (4) HDRBC uptake in the lung was unrelated to reticuloendothelial function, and represented prolonged transit through the lung microvasculature.

  18. Plasma Creatinine Clearance in the Dog

    Science.gov (United States)

    Frazier, Loy W.

    1977-01-01

    Lists materials and methods for an experiment that demonstrates the concept of glomerular filtration rate (GFR) using anesthesized dogs. In the dog, GFR is equivalent to the renal plasma clearance of exogenous creatinine. (CS)

  19. Low ground clearance vehicle detection and warning.

    Science.gov (United States)

    2015-06-01

    A Low Ground Clearance Vehicle Detection : System (LGCVDS) determines if a commercial : motor vehicle can successfully clear a highwayrail : grade crossing and notifies the driver when : his or her vehicle cannot safely traverse the : crossing. That ...

  20. Exclusion, exemption, clearance European Union approach

    International Nuclear Information System (INIS)

    Janssens, A.

    1997-01-01

    The presentation overviews the following issues: Euratom Basic Safety Standards; administrative requirements; radiation protection of the population. Scope of the Standards: natural radiation sources; exclusion. Exemption; Clearance; Import of radioactive scrap metal

  1. Compressor airfoil tip clearance optimization system

    Science.gov (United States)

    Little, David A.; Pu, Zhengxiang

    2015-08-18

    A compressor airfoil tip clearance optimization system for reducing a gap between a tip of a compressor airfoil and a radially adjacent component of a turbine engine is disclosed. The turbine engine may include ID and OD flowpath boundaries configured to minimize compressor airfoil tip clearances during turbine engine operation in cooperation with one or more clearance reduction systems that are configured to move the rotor assembly axially to reduce tip clearance. The configurations of the ID and OD flowpath boundaries enhance the effectiveness of the axial movement of the rotor assembly, which includes movement of the ID flowpath boundary. During operation of the turbine engine, the rotor assembly may be moved axially to increase the efficiency of the turbine engine.

  2. Delayed plasma clearance and hepatic uptake of lymph chylomicron 14C-cholesterol in marginally zinc-deficient rats

    International Nuclear Information System (INIS)

    Koo, S.I.; Algilani, K.; Norvell, J.E.; Henderson, D.A.

    1986-01-01

    Previously, chylomicrons from marginally zinc-deficient rats were shown to be abnormally large, with markedly reduced levels of apoproteins C and E. In the present study, effects of such changes on the plasma clearance and hepatic uptake of chylomicron cholesterol were investigated in rats fed 3 ppm of zinc (ZD), as compared with those fed 30 ppm of zinc (CT). The rate of plasma clearance was determined by plasma 14C-radioactivity at different intervals after intravenous injection of lymph chylomicrons labeled in vivo with 14C-cholesterol. The 14C-clearance curves were nonlinear, consisting of an initial rapid phase followed by a slow phase of clearance. The initial 14C-clearance was significantly (p less than 0.05) delayed whether the labeled chylomicrons from ZD donors were injected into ZD or CT recipients. The hepatic 14C-recovery in extracted lipids was also significantly lower in ZD rats. The present data provide first evidence that a marginal level of zinc deficiency produces a significant delay in the plasma clearance and hepatic uptake of chylomicron cholesterol. This may be attributable in part to the molecular alterations of chylomicrons induced by zinc deficiency

  3. Reduction in slow intercompartmental clearance of urea during dialysis

    International Nuclear Information System (INIS)

    Bowsher, D.J.; Krejcie, T.C.; Avram, M.J.; Chow, M.J.; Del Greco, F.; Atkinson, A.J. Jr.

    1985-01-01

    The kinetics of urea and inulin were analyzed in five anesthetized dogs during sequential 2-hour periods before, during, and after hemodialysis. The distribution of both compounds after simultaneous intravenous injection was characterized by three-compartment models, and the total volumes of urea (0.66 +/- 0.05 L/kg) and inulin (0.19 +/- 0.01 L/kg) distribution were similar to expected values for total body water and extravascular space, respectively. Intercompartmental clearances calculated before dialysis were used to estimate blood flows to the fast and slow equilibrating compartments. In agreement with previous results, the sum of these flows was similar to cardiac output, averaging 101% of cardiac output measured before dialysis (range 72% to 135%). Dialysis was accompanied by reductions in the slow intercompartmental clearances of urea (81%) and inulin (47%), which reflected a 90% attenuation in blood flow supplying the slow equilibrating compartments. This was estimated to result in a 10% average reduction in the efficiency with which urea was removed by dialysis (range 2.0% to 16.4%). Mean arterial pressure fell by less than 5% during dialysis, but total peripheral resistance increased by 47% and cardiac output fell by 35%. In the postdialysis period, total peripheral resistance and cardiac output returned toward predialysis values, but blood flow to the slow equilibrating peripheral compartment was still reduced by 80%. These changes parallel activation of the renin-angiotensin system, but further studies are required to establish causality

  4. Biliary clearance of bromosulfophthalein in healthy and ketotic Holstein cows

    Directory of Open Access Journals (Sweden)

    Danijela Kirovski

    2013-09-01

    Full Text Available Ketosis is a metabolic disorder closely associated with liver lipidosis. Numerous tests have been developed to detect hepatic dysfunction in dairy cows. Bromosulfophthalein (BSP clearance is established as a sensitive index of hepatic function. The objective of this study was to examine the difference of biliary excretion of BSP between ketotic and healthy Holstein cows and to correlate this excretion with other indicators of liver dysfunction. Twenty puerperal Holstein cows divided in two groups (10 cows each were involved in the study. The first group included healthy and the second group ketotic cows. Blood samples were taken 10 days after parturition. Concentrations of total protein, albumin, total bilirubin, Ca, P, total lipids, urea and glucose were determined. Immediately after blood sampling, BSP test was performed. Blood samples were taken 5 and 45 minutes after injection, and the percentage of retained pigment in the sample obtained at minute 45 was calculated. Blood albumin and glucose concentrations were significantly higher in healthy then ketotic cows. Total bilirubin concentration was significantly higher in ketotic than healthy cows. BSP excretion was significantly higher in ketotic compared to healthy cows. There was a significant positive correlation between BSP values and total bilirubin concentrartions in both healthy and ketotic cows and a significant negative correlation between BSP values and glucose concentrartions in both healthy and ketotic cows. In conclusion, biliary clearance of BSP may be used as a reliable method for the detection of hepatic dysfunction associated with clinical symptoms of ketosis in dairy cows.

  5. Teduglutide Injection

    Science.gov (United States)

    ... who need additional nutrition or fluids from intravenous (IV) therapy. Teduglutide injection is in a class of medications ... of the ingredients.tell your doctor and pharmacist what other prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking ...

  6. Dexrazoxane Injection

    Science.gov (United States)

    ... are used to treat or prevent certain side effects that may be caused by chemotherapy medications. Dexrazoxane injection (Zinecard) is used to prevent or decrease heart damage caused by doxorubicin in women who are taking the medication to treat breast cancer that has spread to other parts of the ...

  7. Triptorelin Injection

    Science.gov (United States)

    ... puberty too soon, resulting in faster than normal bone growth and development of sexual characteristics) in children 2 years and older. Triptorelin injection is in a class of medications called gonadotropin-releasing hormone (GnRH) agonists. It works by decreasing the amount ...

  8. Recent activities on clearance in IAEA and clearance automatic laser inspection system (CLALIS)

    International Nuclear Information System (INIS)

    Hattori, Takatoshi; Sasaki, Michiya

    2005-01-01

    Exemption levels for bulk amounts of materials have been described in RS-G-1.7 published as a safety guide in IAEA on August 2004. In Japan, the Nuclear Safety Commission adopted the RS-G-1.7 values as Japanese clearance levels after the careful review of dose assessment results. After completing revises of regulatory laws in relation to clearance level, solid wastes from decommissioning and operating nuclear power plants will be targets of clearance inspection. In CRIEPI, Clearance Automatic Laser Inspection System (CLALIS) has been developed, which can give high reliability and objectivity to the measurement data. The CLALIS is a new monitoring system coupling with 3D laser shape measurement, Monte-Carlo calculation and gamma measurement techniques, which can keep a high accuracy in the measurement data using an automatic correction technique for self-shielding effects of metal waste itself and is expected to apply as a practical use in actual clearance inspections. (author)

  9. Centrifugal compressor tip clearance and impeller flow

    Energy Technology Data Exchange (ETDEWEB)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari [Laboratory of Fluid Dynamics, LUT School of Energy Systems, Lappeenranta University of Technology, Lappeenranta (Finland); Engeda, Abraham [Turbomachinery Laboratory, Dept. of Mechanical Engineering, Michigan State University, East Lansing (United States)

    2016-11-15

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease.

  10. Centrifugal compressor tip clearance and impeller flow

    International Nuclear Information System (INIS)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari; Engeda, Abraham

    2016-01-01

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease

  11. A camera based calculation of 99m Tc-MAG-3 clearance using conjugate views method

    International Nuclear Information System (INIS)

    Hojabr, M.; Rajabi, H.; Eftekhari, M.

    2004-01-01

    Background: measurement of absolute or different renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods is approximations of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in the use of this technique. In this study the conjugate-view method along with some background correction technique have been used for the measurement of renal activity in 99m Tc- MAG 3 renography. Transmission data were used for attenuation correction and the source volume was considered for accurate background subtraction. Materials and methods: the study was performed in 35 adult patients referred to our department for conventional renography and ERPF calculation. Depending on patients weight approximately 10-15 mCi 99 Tc-MAG 3 was injected in the form of a sharp bolus and 60 frames of 1 second followed by 174 frames of 10 seconds were acquired for each patient. Imaging was performed on a dual-head gamma camera(SOLUS; SunSpark10, ADAC Laboratories, Milpitas, CA) anterior and posterior views were acquired simultaneously. A LEHR collimator was used to correct the scatter for the emission and transmission images. Buijs factor was applied on background counts before background correction (Rutland-Patlak equation). gamma camera clearance was calculated using renal uptake in 1-2, 1.5-2.5, 2-3 min. The same procedure was repeated for both renograms obtained from posterior projection and conjugated views. The plasma clearance was also directly calculated by three blood samples obtained at 40, 80, 120 min after injection. Results: 99 Tc-MAG 3 clearance using direct sampling method were used as reference values and compared to the results obtained from the renograms. The maximum correlation was found between conjugate view clearance at 2-3 min (R=0.99, R 2 =0.98, SE=15). Conventional

  12. Determination of the technetium-99m mercaptoacetyltriglycine plasma clearance in children by means of a single blood sample: a multicentre study

    International Nuclear Information System (INIS)

    Piepsz, A.; Gordon, I.; Hahn, K.; Kolinska, J.; Kotzerke, J.; Sixt, R.

    1993-01-01

    A multicentree European study was undertaken in order to determine a reasonable algorithm allowing the determination of overall technetium-99m mercaptoacetyltriglycine clearance using a single blood sample. Employing multiple blood sample clearance as a reference method, it was shown that an acceptable estimation of the MAG3 renal clearance could be obtained using a blood sample taken at any time between 30 and 40 min after tracer injection. After correction for body surface area comparison of clearance determined using (a) the single blood sample and (b) the multiple blood samples provided a coefficient of correlation of 0.949 and an SEE of 27 ml/min. This algorithm is valid for clearance values higher than 100 ml/min/1.73 m 2 and for children older than 1 year of age. (orig.)

  13. Single-sample 99mTc-diethylenetriamine penta-acetate plasma clearance in advanced renal failure by the mean sojourn time approach.

    Science.gov (United States)

    Gref, Margareta C; Karp, Kjell H

    2009-03-01

    The single-sample Tc-diethylenetriamine penta-acetate (DTPA) clearance method by Christensen and Groth is recommended by the Radionuclides in Nephrourology Committee on Renal Clearance for use in adults with an estimated glomerular filtration rate (GFR) > or = 30 ml/min. The purpose of this study was to test a new Tc-DTPA single-sample low clearance formula for GFR lesser than 30 ml/min. Twenty-one adult patients (29 investigations) were included. Reference clearance was calculated with both Cr-EDTA and Tc-DTPA according to Brøchner-Mortensen with samples drawn between 3 and 24 h. Single-sample clearance was calculated from a 24 h sample using the low clearance formula(Equation is included in full-text article.) C(t) is the activity of the tracer in the plasma sample t minutes after the injection and Q0 is the injected amount. ECV is the extracellular volume in ml defined as the distribution volume of the tracer. ECV is estimated from the body surface area as ECV=8116.6xbody surface area-28.2. The mean difference between reference and Tc-DTPA single-sample clearance was -0.5 ml/min (SD 1.0 ml/min) for Tc-DTPA and -0.8 ml/min (SD 1.2 ml/min) for Cr-EDTA as reference clearance. In adult patients it is possible, even with GFR lesser than 30 ml/min, to get an accurate determination of Tc-DTPA plasma clearance from a single sample using the mean sojourn time approach. The blood sample should be obtained about 24 h after injection of the GFR tracer.

  14. Clearance Laboratory - Capability and measurement sensitivity

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.; Lauridsen, B.; Silva, J.; Soegaard-Hansen, J.; Warming, L.

    2005-09-01

    A new low-level Clearance Laboratory has been built at the Risoe-site. Building materials with a low content of naturally occurring radionuclides have been used. To minimize transport of radon gas from soil into the laboratory the foundation has been supplied with a membrane. The laboratory has been equipped with two high-efficiency germanium detectors. These detectors will be used for clearance measurements on the predicted amount of 15,000 - 18,000 tonnes of non-active or nearly non-active materials, which will originate from the decommissioning of all the nuclear facilities at the Risoe-site. They will be used also for clearance measurements on buildings and land. Objects and materials to be measured for clearance are placed on a rotation table that can carry up to one tonne and can rotate once a minute to simulate some averaging of inhomogeneously distributed activity. Sensitivity and background measurements reveal that measuring times of 20 - 50 minutes would normally be sufficient to detect radionuclide concentrations of only a small fraction of the nuclide-specific clearance levels with a sufficiently low uncertainty. Probability calculations of the measurement capacity of the Clearance Laboratory indicate that the mean value of the total measuring time for all materials that potentially can be cleared would be 13 years with a 95% probability of being less than 25 years. The mean value of the annual amount of materials that can be measured in the laboratory is 600 tonnes with a 95% probability of being less than 1,200 tonnes. If needed, there is room for additional measuring systems to increase the capacity of the laboratory. (au)

  15. Clearance Laboratory - Capability and measurement sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Hedemann Jensen, P.; Lauridsen, B.; Silva, J.; Soegaard-Hansen, J.; Warming, L.

    2005-08-01

    A new low-level Clearance Laboratory has been built at the Risoe-site. Building materials with a low content of naturally occurring radionuclides have been used. To minimize transport of radon gas from soil into the laboratory the foundation has been supplied with a membrane. The laboratory has been equipped with two high-efficiency germanium detectors. These detectors will be used for clearance measurements on the predicted amount of 15,000 - 18,000 tonnes of non-active or nearly non-active materials, which will originate from the decommissioning of all the nuclear facilities at the Risoe-site. They will be used also for clearance measurements on buildings and land. Objects and materials to be measured for clearance are placed on a rotation table that can carry up to one tonne and can rotate once a minute to simulate some averaging of inhomogeneously distributed activity. Sensitivity and background measurements reveal that measuring times of 20 - 50 minutes would normally be sufficient to detect radionuclide concentrations of only a small fraction of the nuclide-specific clearance levels with a sufficiently low uncertainty. Probability calculations of the measurement capacity of the Clearance Laboratory indicate that the mean value of the total measuring time for all materials that potentially can be cleared would be 13 years with a 95% probability of being less than 25 years. The mean value of the annual amount of materials that can be measured in the laboratory is 600 tonnes with a 95% probability of being less than 1,200 tonnes. If needed, there is room for additional measuring systems to increase the capacity of the laboratory. (au)

  16. Tear clearance implications for ocular surface health.

    Science.gov (United States)

    de Paiva, Cintia Sade; Pflugfelder, Stephen C

    2004-03-01

    Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.

  17. Recombinant human erythropoietin in humans down-regulates proximal renal tubular reabsorption and causes a fall in glomerular filtration rate

    DEFF Research Database (Denmark)

    Olsen, Niels Vidiendal; Aachmann-Andersen, Niels Jacob; Oturai, Peter

    2010-01-01

    HuEPO for 28 days in doses raising the hematocrit to 48.3 (4.1) %. Renal clearance studies with urine collections (N = 8) were done at baseline and at days 4, 11, 29, and 42. Glomerular filtration rate (GFR) was measured by (51)Cr-EDTA. Renal clearance of lithium (C(Li)) was used as an index of proximal...... tubular outflow and to assess segmental renal tubular handling of sodium and water. rHuEPO-induced increases in hematocrit occurred from day 10 onwards and was caused by both an increase in red cell volume and a fall in plasma volume. Well before that (from day 2 and throughout the treatment time), r...... and water (APR = GFR - C(Li), P

  18. Enalapril dosage in progressive chronic nephropathy

    DEFF Research Database (Denmark)

    Elung-Jensen, Thomas; Heisterberg, Jens; Sonne, Jesper

    2005-01-01

    OBJECTIVE: In chronic renal failure, clearance of enalapril is reduced. Hence, a renoprotective effect may be achieved with lower doses than conventionally used. Since marked inter-patient variation in concentrations of enalaprilat has been shown in patients with renal failure despite equivalent...... dosage of enalapril, a direct comparison of the effect of high versus low plasma concentrations of enalaprilat on the progression of renal failure was undertaken. METHODS: Forty patients with a median glomerular filtration rate (GFR) of 17 (6-35) ml/min/1.73 m2 were studied in an open-label, randomised...... intervals by the plasma clearance of 51Cr-EDTA, and the individual rates of progression of renal failure were calculated as the slope of GFR versus time plot. RESULTS: In the high-concentration group, the median enalaprilat trough concentration was 92.9 ng/ml (21.8-371.0 ng/ml) and in the low...

  19. Estimation of technetium 99m mercaptoacetyltriglycine plasma clearance by use of one single plasma sample

    International Nuclear Information System (INIS)

    Mueller-Suur, R.; Magnusson, G.; Karolinska Inst., Stockholm; Bois-Svensson, I.; Jansson, B.

    1991-01-01

    Recent studies have shown that technetium 99m mercaptoacetyltriglycine (MAG-3) is a suitable replacement for iodine 131 or 123 hippurate in gamma-camera renography. Also, the determination of its clearance is of value, since it correlates well with that of hippurate and thus may be an indirect measure of renal plasma flow. In order to simplify the clearance method we developed formulas for the estimation of plasma clearance of MAG-3 based on a single plasma sample and compared them with the multiple sample method based on 7 plasma samples. The correlation to effective renal plasma flow (ERPF) (according to Tauxe's method, using iodine 123 hippurate), which ranged from 75 to 654 ml/min per 1.73 m 2 , was determined in these patients. Using the developed regression equations the error of estimate for the simplified clearance method was acceptably low (18-14 ml/min), when the single plasma sample was taken 44-64 min post-injection. Formulas for different sampling times at 44, 48, 52, 56, 60 and 64 min are given, and we recommend 60 min as optimal, with an error of estimate of 15.5 ml/min. The correlation between the MAG-3 clearances and ERPF was high (r=0.90). Since normal values for MAG-3 clearance are not yet available, transformation to estimated ERPF values by the regression equation (ERPF=1.86xC MAG-3 +4.6) could be of clinical value in order to compare it with the normal values for ERPF given in the literature. (orig.)

  20. Frequency of stone clearance after extracorporeal shockwave ...

    African Journals Online (AJOL)

    Objective: To determine the rate of stone clearance after extracorporeal shockwave lithotripsy (ESWL) for renal stones in adult patients with renal insufficiency. Subjects and methods: This is a cross-sectional descriptive study of 117 adult patients who underwent ESWL. The indications for ESWL were determined by the ...

  1. Bromsulphalein (BSP) clearance in ageing rats

    NARCIS (Netherlands)

    Hollander, C.F.; Leeuw-Israel, F.R. de; Arp-Neefjes, J.M.

    1968-01-01

    Liver function in ageing rats was studied, using the bromsulphalein (BSP) clearance test. The test was done on ultramicro scale. This made it possible to repeat the test several times in the same animal and to start a longitudinal study. In 3-month-old rats the BSP retentions, measured 15, 30 and 45

  2. Lack of effect of non-steroid antiinflammatory drugs on lithium clearance and on delivery of tubular fluid to the loop of Henle in rats.

    Science.gov (United States)

    Lassen, E; Thomsen, K; Sørensen, S S; Pedersen, E B

    1986-11-01

    This paper examines a possible interaction between non-steroid antiinflammatory drugs (NSAI drugs) and renal lithium clearance in conscious, unoperated rats with diabetes insipidus (Brattleboro strain) and ordinary Wistar rats. The drugs were given with the food for 5 days before clearance determinations in the following daily doses per kg body weight: acetylsalicyclic acid 115 mg/kg, phenylbutazone 20 mg/kg, indomethacin 5 mg/kg, and penicillamine 65 mg/kg. None of the drugs affected the lithium clearance. Also urine flow, sodium clearance, potassium clearance, and prostaglandin E2 excretion remained unaffected by the treatments. The results suggest that a continued lowering of lithium clearance cannot be produced, at least not by administration of the drugs with the food. Since lithium clearance is a quantitative measure of the delivery of tubular fluid from the proximal tubules to the loop of Henle, the results also suggest that chronic administration of NSAI drugs does not influence delivery from the proximal tubules in rats. The lowering of lithium clearance observed by others after administration of the drugs by injection or by gastric tube may have been transient, lasting only for a short period after each administration.

  3. Hepatic drug clearance following traumatic injury.

    Science.gov (United States)

    Slaughter, R L; Hassett, J M

    1985-11-01

    Trauma is a complex disease state associated with physiologic changes that have the potential to alter hepatic drug clearance mechanisms. These responses include alterations in hepatic blood flow, reduction in hepatic microsomal activity, reduction in hepatic excretion processes, and changes in protein binding. Hepatic blood flow is influenced by sympathomimetic activity. Both animal and human studies demonstrate an initial reduction and subsequent increase in hepatic blood flow, which coincides with an observed increase and subsequent return to normal in serum catecholamine concentrations. Unfortunately, there are no human studies that address the importance these findings may have to the clearance processes of high intrinsic clearance compounds. Animal studies of trauma indicate that hepatic microsomal activity is depressed during the post-traumatic period. Reduction in the hepatic clearance of antipyrine, a model low intrinsic compound, has also been demonstrated in animal models of trauma. In addition to these effects, hepatic excretion of substances such as indocyanine green and bilirubin have been demonstrated to be impaired in both traumatized animals and humans. Finally, substantial increases in the serum concentration of the binding protein alpha 1-acid glycoprotein occur in trauma patients. This has been reported to be associated with subsequent decreases in the free fraction of lidocaine and quinidine. In addition to changing serum drug concentration/response relationships, the pharmacokinetic behavior of drugs bound to alpha 1-acid glycoprotein should also change. Preliminary observations in our laboratory in a dog model of surgically-induced trauma have shown a reduction in the total clearance of lidocaine and reduction in free lidocaine concentration.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. DOD PERSONNEL CLEARANCES: Additional OMB Actions Are Needed to Improve the Security Clearance Process

    National Research Council Canada - National Science Library

    2006-01-01

    Our independent analysis of timeliness data showed that industry personnel contracted to work for the federal government waited more than one year on average to receive top secret clearances, longer...

  5. 19 CFR 122.26 - Entry and clearance.

    Science.gov (United States)

    2010-04-01

    ... AIR COMMERCE REGULATIONS Private Aircraft § 122.26 Entry and clearance. Private aircraft, as defined... information as set forth in § 122.22(c), and grants electronic clearance via electronic mail or telephone...

  6. Effects of cigarette smoking on I-123 IMP clearance from the lung

    International Nuclear Information System (INIS)

    Katoh, Kunihiko; Takahashi, Tsuneo

    1990-01-01

    N-isopropyl-p-I-123-iodoamphetamine (I-123 IMP), originally developed as a brain scanning agent, is also taken up by the lung. To evaluate the cigarette smoking on the uptake of IMP by the lung, we studied I-123 IMP clearance from the lung on 14 volunteers; 5 non-smokers and 9 smokers. After the injection of 111 MBq (3mCi) of I-123 IMP into the medial cubital vein, the time-activity curve for 60 minutes and the regional activity using 1 frame per minute and a 64 x 64 matrix was obtained. I-123 IMP clearance curve was described as follows: C(t)=A 1 e -k1t +A 2 e -k2t (A 1 , A 2 : intercepts, and k 1 , k 2 : slopes of the exponential components). I-123 IMP clearance was delayed in smokers, and k 2 was smaller in smokers. Also a significant correlations between k 1 , k 2 , and the number of cigarettes smoked per day were found. In conclusion, this study suggests that the delayed clearance and retention of I-123 IMP in the lung indicate the lung metabolic disorders due to cigarette smoking. (author)

  7. Clearance and binding of radiolabeled glycoproteins by cells of the murine mononuclear phagocyte system

    International Nuclear Information System (INIS)

    Imber, M.J.

    1982-01-01

    The clearance and binding of radiolabeled lactoferrin and fast α 2 -macroglobulin were studied. Both glycoproteins cleared rapidly following intravenous injection in mice, and both bound specifically to discrete receptors on murine peritoneal macrophages. The simultaneous presence of excess, unlabeled ligands specific for receptors recognizing terminal fucose, mannose, N-acetylglucosamine or galactose residues did not inhibit the clearance or binding of either lactoferrin or fast-α 2 M. The clearance and binding of enzymatically defucosylated lactoferrin was indistinguishable from native lactoferrin, indicating that terminal α(1-3)-linked fucose on lactoferrin is not necessary for receptor recognition. The clearance and binding of two fast -α 2 M forms, α 2 M-trypsin and α 2 M-MeNH 2 cross compete with each other. Saturation binding studies indicated that the total binding of mannosyl -BSA, fusocyl-BSA, and N-acetylglucosaminyl-BSA to macrophages activated by BCG was approximately 15% of the levels observed with inflammatory macrophages elicited by thioglycollate broth. Cross-competition binding studies demonstrated a common surface receptor mediated binding of all three neoglycoprotein ligands and was identical to the receptor on mononuclear phagocytes that binds mannosyl- and N-acetylglucosaminyl-terminated glycoproteins. These results suggest that difference between discrete states of macrophage function may be correlated with selective changes in levels of the surface receptor for mannose-containing glycoproteins

  8. Influence of chest background on pulmonary 99m Tc-DTPA clearance in interstitial lung disease

    International Nuclear Information System (INIS)

    Ishizaka, Akitoshi; Kanazawa, Minoru; Suzuki, Yukio; Hasegawa, Naoki; Kubo, Atsushi; Kawashiro, Takeo

    1992-01-01

    The authors examined the effect of chest extracellular 99m T c -diethylenetriamine pentaacetate (DTPA) as a background in the measurement of pulmonary 99m T c -DTPA clearance in patients with interstitial lung disease (ILD). Eight healthy nonsmokers (HN) and eight patients with ILD were studied. They monitored changes in gamma counts after the inhalation of 99m T c -DTPA aerosol by using a gamma camera placed over the anterior chest. The rate constant of pulmonary 99m T c -DTPA clearance (k; %/min) was assessed by calculating the slope of the decrease in the gamma counts. The chest background, estimated by 99m T c -DTPA intravenous injection, was subtracted from the original data to obtain the corrected DTPA clearance (k c ; %/min). In patients with ILD, k was significantly greater [2.19 ± 1.03 (SD) %/min; n = 8] compared with HN (0.86 ± 0.17%/min; n = 8; P c was also greater (2.80 ± 1.15%/min; n = 8; P c among all subjects (r = 0.987, P 99m T c -DTPA clearance. 16 refs., 2 figs., 2 tabs

  9. Effect of glycation of albumin on its renal clearance in normal and diabetic rats

    International Nuclear Information System (INIS)

    Layton, G.J.; Jerums, G.

    1988-01-01

    Two independent techniques have been used to study the renal clearances of nonenzymatically glycated albumin and nonglycated albumin in normal and streptozotocin-induced diabetic rats, 16 to 24 weeks after the onset of diabetes. In the first technique, serum and urinary endogenous glycated and nonglycated albumin were separated using m-aminophenylboronate affinity chromatography and subsequently quantified by radioimmunoassay. Endogenous glycated albumin was cleared approximately twofold faster than nonglycated albumin in normal and diabetic rats. However, no difference was observed in the glycated albumin/nonglycated albumin clearance ratios (Cga/Calb) in normal and diabetic rats, respectively (2.18 +/- 0.39 vs 1.83 +/- 0.22, P greater than 0.05). The second technique measured the renal clearance of injected 125I-labelled glycated albumin and 125I-labelled albumin. The endogenous results were supported by the finding that 125I-labelled glycated albumin was cleared more rapidly than 125I-labelled albumin in normal (P less than 0.01) and diabetic (P less than 0.05) rats. The Cga/Calb ratio calculated for the radiolabelled albumins was 1.4 and 2.0 in normal and diabetic rats, respectively. This evidence suggests that nonenzymatic glycation of albumin increases its renal clearance to a similar degree in normal and diabetic rats

  10. Diminished creatinine clearance in anorexia nervosa: reversal with weight gain.

    OpenAIRE

    Boag, F; Weerakoon, J; Ginsburg, J; Havard, C W; Dandona, P

    1985-01-01

    To assess whether patients with anorexia nervosa have abnormalities in creatinine clearance, we measured plasma creatinine concentration, urinary creatinine excretion, and creatinine clearance in 10 patients with anorexia nervosa before and during treatment. Urinary creatinine excretion and creatinine clearance were diminished in all patients. Nine patients had significant decreases in their plasma creatinine and creatinine clearance was increased even when corrected for body weight and body ...

  11. 48 CFR 801.602-76 - Business clearance review.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Business clearance review... GENERAL DEPARTMENT OF VETERANS AFFAIRS ACQUISITION REGULATION SYSTEM Career Development, Contracting Authority, and Responsibilities 801.602-76 Business clearance review. (a) A business clearance review is a...

  12. 7 CFR 1927.55 - Title clearance services.

    Science.gov (United States)

    2010-01-01

    ... REGULATIONS TITLE CLEARANCE AND LOAN CLOSING Real Estate Title Clearance and Loan Closing § 1927.55 Title clearance services. (a) Responsibilities of closing agents. Services to be provided to the agency and the borrower by a closing agent in connection with the transaction vary depending on whether a title insurance...

  13. 48 CFR 2452.237-75 - Clearance of contractor personnel.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Clearance of contractor... Clauses 2452.237-75 Clearance of contractor personnel. As prescribed in 2437.110(e), insert the following clause in solicitations and contracts. Clearance of Contractor Personnel (OCT 1999) (a) General. This...

  14. 14 CFR 1260.63 - Customs clearance and visas.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  15. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  16. CO2 clearance by membrane lungs.

    Science.gov (United States)

    Sun, Liqun; Kaesler, Andreas; Fernando, Piyumindri; Thompson, Alex J; Toomasian, John M; Bartlett, Robert H

    2018-05-01

    Commercial membrane lungs are designed to transfer a specific amount of oxygen per unit of venous blood flow. Membrane lungs are much more efficient at removing CO 2 than adding oxygen, but the range of CO 2 transfer is rarely reported. Commercial membrane lungs were studied with the goal of evaluating CO 2 removal capacity. CO 2 removal was measured in 4 commercial membrane lungs under standardized conditions. CO 2 clearance can be greater than 4 times that of oxygen at a given blood flow when the gas to blood flow ratio is elevated to 4:1 or 8:1. The CO 2 clearance was less dependent on surface area and configuration than oxygen transfer. Any ECMO system can be used for selective CO 2 removal.

  17. Pipeline dynamics subject to restraints with clearance

    International Nuclear Information System (INIS)

    Loula, A.F.D.; Guerreiro, J.N.C.

    1980-12-01

    The principle of virtual works at its incremental form, is utilized for the formulation of flat pipeline vibration problems, of elastic-plastic behavior, submitted to restraints with clearance (also with elastic-plastic behavior) and with viscous damping. The possibility of uniform movement of the support, that simulates the seismic action is also considered. The finite element method and an integration time algorithm, are utilized for the problem resolution. Some examples ilustrate the application of the development program. (Author) [pt

  18. Tip Clearance Control Using Plasma Actuators

    Science.gov (United States)

    2007-03-01

    Clearance Control Using Plasma Actuators 4 posed by Denton (1993). A number of investigators have used partial shrouds, or " winglet " designs to...SDBD actuator Plasma enhanced aerodynamics has been demonstrated in a range of applications involving sepa- ration control, lift enhancement, drag... aerodynamic benefits of a squealer tip geometry. Specifically, the squealer tip is known to reduce the discharge coefficient of the tip gap, thereby

  19. Clearance level and industrial waste management

    International Nuclear Information System (INIS)

    Asano, Toichi

    1999-01-01

    Defining the clearance level enables the radioactive waste with lower radioactivity than a certain level to be the general industrial waste and therefore consideration for public acceptance is essential. For this, it is necessary to understand laws concerning not only atomic power and radioactivity but also disposal and cleaning of general waste. It is also necessary that the waste below the clearance level should be as much as possible handled in the modern common concept of recycling of resources. In 1996, the weight of industrial waste was about 400 million tons, of which 40% was disposed by burning and dehydration, 39% was re-used and 21% was subjected to the final disposal like reclamation. Reduction, re-use and recycling of the generated waste are required for making the society with recycling of resources. Scrap concrete materials below the clearance level of 0.6 million tons are estimated to be generated by dismantling the light water reactor of 1 million kW output and profitable technology for recycling the scrap is under investigation. (K.H.)

  20. Establishing exemption and clearance criteria by the regulatory authority

    International Nuclear Information System (INIS)

    Salih, A.E.A.

    2012-04-01

    This Project work discusses the relationship between the concepts of exemption and clearance, and their practical use in the overall scheme of regulatory control of practices. It also discusses how exemptions and clearance is established and the scope of its applications for regulatory control. The concept of general clearance levels for any type of material and any possible pathway of disposal is also introduced in this work. Guidance of the Group of Experts establishing scenarios for general clearance, parameter values, and a nuclide-specific list of calculated clearance levels is also presented. Regulatory authorities are required to develop guidance on exemption and clearance levels to assist licensees and registrants to know which practices and sources within practices are exempted from regulatory control and those to be cleared from further controls. Exemption and clearance levels are tools for assisting the Regulatory Authority to optimize the use of resources. (author)

  1. Retention and clearance of C-11 palmitic acid in ischemic and reperfused canine myocardium

    International Nuclear Information System (INIS)

    Schwaiger, M.; Schelbert, H.R.; Keen, R.; Vinten-Johansen, J.; Hansen, H.; Selin, C.; Barrio, J.; Huang, S.C.; Phelps, M.E.

    1985-01-01

    Free fatty acids are the major energy source for cardiac muscle. Oxidation of fatty acid decreases or even ceases during ischemia. Its recovery after transient ischemia remains largely unexplored. Using intracoronary carbon-11 palmitic acid as a tracer of myocardial fatty acid metabolism in an open chest dog model, retention and clearance of tracer in myocardium were evaluated at control, during ischemia and after reperfusion following a 20 minute occlusion of the left anterior descending coronary artery. Myocardial C-11 time-activity curves were analyzed with biexponential curve-fitting routines yielding fractional distribution and clearance half-times of C-11 palmitic acid in myocardial tissue. In animals with permanent occlusion and intracoronary injection of C-11 palmitic acid distal to the occlusion site, the relative size and half-time of the early clearance curve component differed markedly from control values and did not change with ongoing ischemia. Conversely, in animals with only 20 minutes of coronary occlusion, the relative size of the early C-11 clearance phase was still significantly depressed at 20 and 90 minutes of reperfusion but returned to control level at 180 minutes. Tissue C-11 clearance half-times remained significantly prolonged throughout the reperfusion period. Regional function in reperfused myocardium monitored with ultrasonic crystals recovered slowly and was still less than control after 3 hours of reperfusion. The data indicate that after transient ischemia, myocardial fatty acid metabolism fails to recover immediately. Because the metabolic recovery occurs in parallel with recovery of regional function, C-11 palmitic acid in conjunction with positron tomography may be useful for studying regional fatty acid metabolism noninvasively after an ischemic injury, and may be helpful in identifying reversible tissue injury

  2. Tissue Clearance of {sup 131}I and Total Peripheral Resistance in Myocardial Infarction and Hypertension, and During Angiotensin Infusion

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, F. K.; Bors, K. J.; Long, T. E.; Lestina, J. [University of Southern California School of Medicine, Los Angeles, CA (United States)

    1971-02-15

    Tissue clearance of {sup 131}I from the thigh, cardiac output and peripheral resistance was determined in 25 patients: 13 normotensive with recent myocardial infarction but not in congestive heart failure, 7 with hypertension and 5 normotensive control subjects. The effect of the synthesized pressor agent Angiotensin II on the same three measurements was also studied. The present investigation continues a previous one of ours, where a tracer dose of {sup 131}I was injected into the thigh of patients with recent myocardial infarction without signs of heart failure, and its clearance was found to be longer than that of normal subjects. This was thought to be due to increased peripheral resistance or to reduced perfusion of the capillary bed secondary to lowered cardiac output, With the 25 subjects, injection into the thigh of tracer amounts of radioactive iodine was done by Hypospray, a method with distinct advantages over needle injection. After measuring tissue clearance of the tracer, cardiac output was determined by a method which records the transit of the injected radioactive bolus through the heart. The Angiotensin was administered by intravenous infusion to four of the normotensive and one of the hypertensive patients. Calculations of cardiac output, total peripheral resistance, mean blood pressure and blood volume were made by means of standard formulae. Results of the study confirmed expectations. Those patients with myocardial infarction who had delayed tissue clearance of {sup 131}I also had reduced cardiac output. The patients with hypertension had normal tissue clearance of {sup 131}I and normal cardiac output in the presence of increased peripheral resistance. Equivalent hypertension and increased peripheral resistance induced in normotensive subjects by Angiotensin resulted in lowered cardiac output and delayed tissue clearance of {sup 131}I. An increased sensitivity to Angiotensin was noted in hypertensive patients. The tissue clearance of {sup 131}I

  3. Fate of tumor cells injected into left ventricle of heart in BALB/c mice: role of natural killer cells

    DEFF Research Database (Denmark)

    Basse, P; Hokland, P; Heron, I

    1988-01-01

    The arrest, retention, and elimination (i.e., clearance) of radiolabeled YAC-1 lymphoma cells injected either iv or into the left ventricle (LV) of the heart were studied in male BALB/c mice, with special emphasis on the role of natural killer (NK) cells. After iv injection YAC-1 cells were...... extent, the bone, skin, and muscle. The only organs that could arrest the LV-injected tumor cells were the lungs and the liver. In the lungs clearance of YAC-1 cells began immediately after the cells were arrested. However, the rate of clearance could be almost abrogated by pretreatment of the recipients...... with anti-asialo GM1 antiserum, which destroys most of the NK cells in vivo and strongly depresses the in vitro NK cell activity. In contrast, YAC-1 cells arrested in the liver were not cleared from this organ during the first 1-2 hours after arrest. After this delay clearance of the cells commenced...

  4. Use of scintigraphy for the determination of mucociliary clearance rates in normal, sedated, diseased and exercised horses.

    Science.gov (United States)

    Willoughby, R A; Ecker, G L; McKee, S L; Riddolls, L J

    1991-01-01

    Mucociliary clearance rates from the trachea were determined in normal, sedated, diseased and exercised horses from scintigraphs obtained after an injection of technetium-99m sulphide colloid into the tracheal lumen. The group mean tracheal clearance rate of eight clinically normal horses during 42 trials was 2.06 +/- 0.38 cm/min. Significant between horse differences were found (p less than 0.05). When six and seven of these horses were given xylazine and detomidine hydrochloride, respectively, mean group tracheal clearance rates dropped significantly (p less than 0.05). The decreases from each normal horse's mean tracheal clearance rate ranged from 18 to 54%. There did not appear to be a difference between the tracheal clearance rates (TCRs) of the normal horses and those with chronic respiratory disease. Postexercise evaluations were not significantly different from the pre-exercise TCRs in three clinically normal horses and three horses with chronic obstructive pulmonary disease (p greater than 0.05). This minimally invasive scintigraphic technique for determining TCRs has proved to be useful and reliable. Images Fig. 1. PMID:1790485

  5. Heparin induced alterations in clearance and distribution of blood-borne microparticles following operative trauma.

    Science.gov (United States)

    Saba, T M; Antikatzides, T G

    1979-04-01

    The influence of systemic heparin administration on the vascular clearance and tissue distribution of blood-borne microparticles was evaluated in normal rats and rats after operation (laparotomy plus intestinal manipulation) utilizing an (131)I- colloid which is phagocytized by the reticuloendothelial system (RES). Intravenous heparin administration (100 USP/100g body weight) into normal animals three minutes prior to colloid injection (50 mg/lOOg) induced a significant increase in pulmonary localization of the microparticles as compared to nonheparinized control rats, while hepatic and splenic uptake were decreased. Surgical trauma decreased hepatic RE uptake and increased pulmonary localization of the microparticles when injected systemically at 60 minutes postsurgery. Heparin administration 60 minutes after surgery and three minutes prior to colloid injection, magnified the increased pulmonary localization response with an associated further depression of the RES. The ability of heparin to alter both RE clearance function and lung localization of microparticles was dose dependent and a function of the interval between heparin administration and systemic particulate infusion. Thus, low dose heparin administration was capable of stimulating RE activity while heparin in doses of excess of 50 USP units/lOOg body weight decreased RE function. These findings suggest that the functional state of the hepatic RE system can be greatly affected in a dose-dependent manner by systemic heparin administration which may influence distribution of blood-borne microparticles.

  6. 50 years follow-up on plasma creatinine levels after spinal cord injury

    DEFF Research Database (Denmark)

    Elmelund, Marlene; Oturai, P S; Biering-Sørensen, F

    2014-01-01

    STUDY DESIGN: Retrospective chart review. OBJECTIVES: To investigate the role of plasma creatinine (p-creatinine) in monitoring renal deterioration in patients up to 50 years after spinal cord injury (SCI). SETTING: The Clinic for Spinal Cord Injuries, Rigshospitalet, Denmark. METHODS: A total...... of 119 patients with a traumatic SCI during the years 1944-1975 were included in the study. P-creatinine measurements, results from renography and glomerular filtration rate (GFR) measured with 51Cr-EDTA clearance were obtained from medical records and analyzed using a linear mixed model and linear...... regression analyses. RESULTS: When compared with median p-creatinine level in the first 5-year period after injury, the level of p-creatinine was stable throughout the first 30 years and decreased significantly after the 30th until 45th year post injury. Only patients with a functional distribution outside...

  7. Differences between nisoldipine and lisinopril on glomerular filtration rates and albuminuria in hypertensive IDDM patients with diabetic nephropathy during the first year of treatment

    DEFF Research Database (Denmark)

    Rossing, P; Tarnow, L; Boelskifte, S

    1997-01-01

    were required in 10 nisoldipine- and 8 lisinopril-treated patients. Every 3 months, 24-h ambulatory blood pressure (TM2420, A&D, Tokyo, Japan) and albuminuria in three 24-h samples (enzyme immunoassay) were measured; GFR (51Cr-EDTA plasma clearance) was recorded every 6 months. Mean arterial blood......-blind, double-dummy, randomized, controlled study comparing nisoldipine (20-40 mg once daily) with lisinopril (10-20 mg once daily) in 52 hypertensive IDDM subjects with diabetic nephropathy. Three patients dropped out, and results for the remaining 49 (25 nisoldipine, 24 lisinopril) are presented. Diuretics...... pressure (24 h) was reduced from (mean +/- SE) 108 +/- 3 mmHg at baseline to 101 +/- 2 in average during treatment in the lisinopril group and from 105 +/- 2 to 103 +/- 2 in the nisoldipine group (P = 0.06 comparing changes in the two groups). Albuminuria was reduced 47% (95% CI 21-65) in the lisinopril...

  8. Optimal dose of losartan for renoprotection in diabetic nephropathy

    DEFF Research Database (Denmark)

    Andersen, Steen; Rossing, Peter; Juhl, Tina R

    2002-01-01

    filtration rate (GFR) ([(51)Cr]EDTA plasma clearance) were determined. RESULTS: Baseline values of albuminuria (geometric mean (95% CI)) and GFR (means+/-SEM) were 1138 (904-1432) mg/24 h and 91+/-3 ml/min/1.73 m(2), respectively. The blood pressure at baseline was 155/81+/-3/2 mmHg. All doses of losartan...... consecutive hypertensive type 1 diabetic patients with diabetic nephropathy received increasing doses of losartan, 50, 100, and 150 mg once daily in three periods each lasting 2 months. At baseline and at the end of each treatment period, albuminuria, 24-h blood pressure (TM2420 A&D), and glomerular...

  9. Long-term effect of lisinopril and atenolol on kidney function in hypertensive NIDDM subjects with diabetic nephropathy

    DEFF Research Database (Denmark)

    Nielsen, F S; Rossing, P; Gall, M A

    1997-01-01

    , 27 men) who completed at least 12 months of the study period are presented. At baseline, the two groups were comparable: glomerular filtration rate (51Cr-EDTA plasma clearance) was 75 +/- 6 and 74 +/- 8 ml x min(-1) x 1.73 m(-2), mean 24-h ambulatory blood pressure (A&D TM2420) was 110 +/- 3 and 114...... +/- 2 mmHg, and 24-h urinary albumin excretion rate was 961 (range 331-5,727) and 1,578 (476-5,806) mg/24 h in the lisinopril and atenolol groups, respectively. The mean follow-up time was similar, 37 and 35 months in the lisinopril and atenolol groups, respectively. Mean ambulatory blood pressure...

  10. Changes in urinary excretion of water and sodium transporters during amiloride and bendroflumethiazide treatment

    DEFF Research Database (Denmark)

    Jensen, Janni M; Mose, Frank H; Kulik, Anna-Ewa O

    2015-01-01

    AIM: To quantify changes in urinary excretion of aquaporin2 water channels (u-AQP2), the sodium-potassium-chloride co-transporter (u-NKCC2) and the epithelial sodium channels (u-ENaC) during treatment with bendroflumethiazide (BFTZ), amiloride and placebo. METHODS: In a randomized, double....... General linear model with repeated measures or related samples Friedman's two-way analysis was used to compare differences. Post hoc Bonferroni correction was used for multiple comparisons of post infusion periods to baseline within each treatment group. RESULTS: At baseline there were no differences in u...... by the constant infusion clearance technique with (51)Cr-EDTA as reference substance. To estimate the changes in water transport via AQP2 and sodium transport via NKCC2 and ENaC, u-NKCC2, the gamma fraction of ENaC (u-ENaCγ), and u-AQP2 were measured at baseline and after infusion with 3% hypertonic saline. U...

  11. Tamm-Horsfall protein in urine after uninephrectomy/transplantation in kidney donors and their recipients

    DEFF Research Database (Denmark)

    Torffvit, O; Kamper, A L; Strandgaard, S

    1997-01-01

    Tamm-Horsfall protein (THP) is a large glycoprotein with unknown physiological function synthesized in the thick ascending limb of the loop of Henle. Urinary THP has recently been suggested as being suitable for monitoring the functional state of transplanted kidneys. In the present study......, the urinary excretion of THP after uninephrectomy and transplantation among relatives was determined in order to study the influence of the acute reduction in renal mass on the excretion of this peptide. Glomerular filtration rate (GFR), estimated by the plasma clearance of 51Cr-EDTA, and the excretion rate...... of THP were measured 2 days before nephrectomy and 5, 12, 26 and 54 days after nephrectomy/transplantation in 22 healthy living kidney donors and in 16 of their recipients. In the donors, THP excretion rate of the kidney to remain in the donor was 22.3 micrograms/min before and 33.7 micrograms/min at 5...

  12. Plasma concentration of asymmetric dimethylarginine (ADMA) predicts cardiovascular morbidity and mortality in type 1 diabetic patients with diabetic nephropathy

    DEFF Research Database (Denmark)

    Lajer, Maria Stenkil; Tarnow, Lise; Jorsal, Anders

    2008-01-01

    OBJECTIVE: To investigate whether circulating asymmetric dimethylarginine (ADMA) levels are predictive of cardiovascular events, decline in glomerular filtration rate (GFR), end-stage renal disease (ESRD), and all-cause mortality in type 1 diabetic patients. RESEARCH DESIGN AND METHODS: We...... performed a prospective observational follow-up study including 397 type 1 diabetic patients with overt diabetic nephropathy (243 men aged 42.1 +/- 10.5 years, GFR 76 +/- 34 ml/min per 1.73 m(2)) and a control group of 175 patients with longstanding type 1 diabetes and persistent normoalbuminuria (104 men...... aged 42.7 +/- 9.7 years, duration of diabetes 27.7 +/- 8.3 years). Patients were followed for a median 11.3 years (range 0.0-12.9) with yearly measurements of GFR ((51)Cr-EDTA plasma clearance) in patients with diabetic nephropathy. Endpoints were fatal and nonfatal cardiovascular disease (CVD...

  13. Comparison of methods for estimating glomerular filtration rate in head and neck cancer patients treated with cisplatin

    DEFF Research Database (Denmark)

    Lindberg, Lotte; Brødbæk, Kasper; Hägerström, Erik G

    2017-01-01

    Cisplatin is a chemotherapeutic agent widely used in the treatment of various solid tumors. Cisplatin induces nephrotoxicity and may lead to long-term reduction of kidney function. Consequently, determination of glomerular filtration rate (GFR) is used to monitor potential kidney damage. This study...... aimed to compare two commonly used algorithms for estimating GFR (eGFR) from plasma creatinine (PCr) with 51Cr-EDTA clearance (CrCl) as a reference method. This was a retrospective single center study of 94 head and neck cancer patients treated with cisplatin. CrCl was performed once before, during......, and after treatment, and PCr was measured concurrently. eGFR was assessed from PCr applying the Cockcroft-Gault (CG) and the Chronic Kidney Disease-Epidemiology Collaboration (CKD-EPI) equations. Agreement was assessed applying the statistical methods of Bland and Altman. A predefined limit of clinically...

  14. Recombinant adeno-associated virus: efficient transduction of the rat VMH and clearance from blood.

    Directory of Open Access Journals (Sweden)

    Margriet A van Gestel

    Full Text Available To promote the efficient and safe application of adeno-associated virus (AAV vectors as a gene transfer tool in the central nervous system (CNS, transduction efficiency and clearance were studied for serotypes commonly used to transfect distinct areas of the brain. As AAV2 was shown to transduce only small volumes in several brain regions, this study compares the transduction efficiency of three AAV pseudotyped vectors, namely AAV2/1, AAV2/5 and AAV2/8, in the ventromedial nucleus of the hypothalamus (VMH. No difference was found between AAV2/1 and AAV2/5 in transduction efficiency. Both AAV2/1 and AAV2/5 achieved a higher transduction rate than AAV2/8. One hour after virus administration to the brain, no viral particles could be traced in blood, indicating that no or negligible numbers of virions crossed the blood-brain barrier. In order to investigate survival of AAV in blood, clearance was determined following systemic AAV administration. The half-life of AAV2/1, AAV2/2, AAV2/5 and AAV2/8 was calculated by determining virus clearance rates from blood after systemic injection. The half-life of AAV2/2 was 4.2 minutes, which was significantly lower than the half-lives of AAV2/1, AAV2/5 and AAV2/8. With a half-life of more than 11 hours, AAV2/8 particles remained detectable in blood significantly longer than AAV2/5. We conclude that application of AAV in the CNS is relatively safe as no AAV particles are detectable in blood after injection into the brain. With a half-life of 1.67 hours of AAV2/5, a systemic injection with 1×109 genomic copies of AAV would be fully cleared from blood after 2 days.

  15. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... sures regarding disposable injection equipment, waste containers, hand hygiene ... injection practices lead to high prevalence of NSSIs in operating rooms. .... guidelines, the availability of training courses to HCWs, and provi-.

  16. Clearance and release from control - An international perspective

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    2005-01-01

    This paper tries to give an overview of the clearance, or release from regulatory control, on an international scale, including some of those countries where clearance has become or is about to become vital for D and D. The emphasis lies on the impact of clearance, and in particular of differences between clearance levels of various countries, on D and D. Relevance of clearance for D and D of nuclear installations Clearance is an essential part of waste management (or more general, material management) in nuclear installations, and in particular during the decommissioning phase where waste streams continues to arise. Of course, the relevance of clearance in a particular country depends on a number of factors, like: availability of a final repository and its price; prevailing decommissioning strategy; number of nuclear installations reaching decommissioning phase. This small selection of reasons why clearance may be of varying importance for different countries may already suffice to illustrate why up to now clearance has been developed and implemented in quite different ways. If one thinks of additional reasons that may influence clearance, like politics, the public opinion, availability of funds etc., the situation becomes even more complex. It is, however safe to draw the conclusion that countries with a certain number of nuclear installations which have been or will soon be shut down or which are already in the decommissioning phase will need to implement provisions for clearance. This has indeed been the case with countries like the UK, Germany, the USA, Sweden, and a number of others. It is not essential for clearance levels to be exactly equal between various countries. They may differ as long as the difference is not too large, e.g. the values fall into the same order of magnitude. This is the reason why for example Germany has no problems with clearance levels which differ from the EU recommendation RP 122 partially adopted in a number of EU countries

  17. Investigations of renal clearance in nuclear medicine

    International Nuclear Information System (INIS)

    Oberhausen, E.

    1981-01-01

    Comparative investigations of PAH- and inulin-clearance and results of investigations with J-131-hippurate and Cr-51-EDTA, which were performed by a partly screened whole body counter including measurements of activity retention of blood samples, are showing good correlation. If the radio-isotope nephrography is worked out together with the decreased retention curve, separate results of the function of both kidneys can be given. Modifications which were tried to analyze a small part of the retention curve instead of the whole body are inaccurate, if they are below 300 ml/min. (orig.) [de

  18. Glial K(+) Clearance and Cell Swelling

    DEFF Research Database (Denmark)

    Macaulay, Nanna; Zeuthen, Thomas

    2012-01-01

    An important feature of neuronal signalling is the increased concentration of K(+) in the extracellular space. The K(+) concentration is restored to its original basal level primarily by uptake into nearby glial cells. The molecular mechanisms by which K(+) is transferred from the extracellular...... space into the glial cell are debated. Although spatial buffer currents may occur, their quantitative contribution to K(+) clearance is uncertain. The concept of spatial buffering of K(+) precludes intracellular K(+) accumulation and is therefore (i) difficult to reconcile with the K(+) accumulation...

  19. The effect of insulin deficiency on the plasma clearance and exchange of high-density-lipoprotein phosphatidylcholine in rats.

    OpenAIRE

    Martins, I J; Redgrave, T G

    1992-01-01

    Triolein/cholesteryl oleate/cholesterol/phosphatidylcholine emulsions designed to model the lipid composition of chylomicrons were injected intravenously into control and streptozotocin-treated insulin-deficient rats. As previously described for lymph chylomicrons, the emulsion triolein was hydrolysed and phosphatidylcholine was transferred to the plasma high-density lipoproteins (HDL). This mechanism was used to introduce a phospholipid label into HDL in vivo. The subsequent clearance of pho...

  20. Injection Laryngoplasty Materials

    OpenAIRE

    Haldun Oðuz

    2013-01-01

    Injection laryngoplasty is one of the treatment options for voice problems. In the recent years, more safe and more biocompatible injection materials are available on the market. Long and short term injection materials are discussed in this review.

  1. Penicillin G Procaine Injection

    Science.gov (United States)

    Penicillin G procaine injection is used to treat certain infections caused by bacteria. Penicillin G procaine injection should not be used to ... early in the treatment of certain serious infections. Penicillin G procaine injection is in a class of ...

  2. Numerical investigation of hub clearance flow in a Kaplan turbine

    Science.gov (United States)

    Wu, H.; Feng, J. J.; Wu, G. K.; Luo, X. Q.

    2012-11-01

    In this paper, the flow field considering the hub clearance flow in a Kaplan turbine has been investigated through using the commercial CFD code ANSYS CFX based on high-quality structured grids generated by ANSYS ICEM CFD. The turbulence is simulated by k-ω based shear stress transport (SST) turbulence model together with automatic near wall treatments. Four kinds of simulations have been conducted for the runner geometry without hub clearance, with only the hub front clearance, with only the rear hub clearance, and with both front and rear clearance. The analysis of the obtained results is focused on the flow structure of the hub clearance flow, the effect on the turbine performance including hydraulic efficiency and cavitation performance, which can improve the understanding on the flow field in a Kaplan turbine.

  3. Numerical investigation of hub clearance flow in a Kaplan turbine

    International Nuclear Information System (INIS)

    Wu, H; Feng, J J; Wu, G K; Luo, X Q

    2012-01-01

    In this paper, the flow field considering the hub clearance flow in a Kaplan turbine has been investigated through using the commercial CFD code ANSYS CFX based on high-quality structured grids generated by ANSYS ICEM CFD. The turbulence is simulated by k-ω based shear stress transport (SST) turbulence model together with automatic near wall treatments. Four kinds of simulations have been conducted for the runner geometry without hub clearance, with only the hub front clearance, with only the rear hub clearance, and with both front and rear clearance. The analysis of the obtained results is focused on the flow structure of the hub clearance flow, the effect on the turbine performance including hydraulic efficiency and cavitation performance, which can improve the understanding on the flow field in a Kaplan turbine.

  4. Evaluation of serum iohexol clearance for use in predicting carboplatin clearance in cats.

    Science.gov (United States)

    Bailey, Dennis B; Rassnick, Kenneth M; Prey, Joshua D; Dykes, Nathan L

    2009-09-01

    To determine whether a glomerular filtration rate (GFR) assay based on serum iohexol clearance can be used to predict carboplatin clearance in cats. 10 cats with tumors. GFR was measured concurrently by use of plasma clearance of technetium Tc 99m-labeled diethylenetriaminepentaacetic acid ((99m)Tc-DTPA) to yield GFR(99mTc-DTPA) and serum clearance of iohexol to yield GFR(Iohexol). A single dose of carboplatin was administered IV as a bolus. Dose was calculated by use of a target value for the area under the plasma platinum concentration-versus-time curve (AUC(Target)) and estimation of platinum clearance (CL(PT)) derived from GFR(99mTc-DTPA) as follows: dose = AUC(Target) x 2.6 x GFR(99mTc-DTPA) x body weight, where AUC(Target) is 2.75 min.mg.mL(-1). Plasma platinum concentrations were measured via atomic absorption spectrophotometry. Values for GFR(99mTc-DTPA) and GFR(Iohexol) were compared by use of least-squares regression and Bland-Altman analysis. Least-squares regression was used to determine whether CL(PT) could be predicted from GFR(99mTc-DTPA) or GFR(Iohexol) (or both). GFR(99mTc-DTPA) and GFR(Iohexol) were strongly correlated (r = 0.90), but GFR(Iohexol) values were significantly larger by a factor of approximately 1.4. Platinum clearance had a significant linear relationship to GFR(99mTc-DTPA) (CL(PT) = 2.5 x GFR(99mTc-DTPA)) and to GFR(Iohexol) (CL(PT) = [1.3 x GFR(Iohexol)] + 1.4). In cats, serum iohexol clearance was an accurate predictor of CL(PT) and can be used to calculate the carboplatin dose as follows: dose = AUC(Target) x ([1.3 x GFR(Iohexol)] + 1.4) x body weight.

  5. The effect of insulin deficiency on the plasma clearance and exchange of high-density-lipoprotein phosphatidylcholine in rats.

    Science.gov (United States)

    Martins, I J; Redgrave, T G

    1992-01-01

    Triolein/cholesteryl oleate/cholesterol/phosphatidylcholine emulsions designed to model the lipid composition of chylomicrons were injected intravenously into control and streptozotocin-treated insulin-deficient rats. As previously described for lymph chylomicrons, the emulsion triolein was hydrolysed and phosphatidylcholine was transferred to the plasma high-density lipoproteins (HDL). This mechanism was used to introduce a phospholipid label into HDL in vivo. The subsequent clearance of phospholipid radioactivity from the plasma of insulin-deficient rats was significantly slower than in controls (P less than 0.025). Plasma clearance was similarly slower in insulin-deficient rats after injection of HDL that was previously labelled with radioactive phospholipids. After injection, the phospholipid label redistributed rapidly between the large-particle fraction of plasma lipoproteins (very-low- and low-density lipoproteins), and the lighter and heavier fractions of HDL. Compared with control rats, in insulin-deficient rats less of the phospholipid label was distributed to the lighter HDL fraction and more to the heavier HDL fraction, and this difference was not due to changes in activity of lecithin: cholesterol acyltransferase or in the apparent activity of phospholipid transfer protein. In insulin-deficient rats the changes in HDL phospholipid clearance and exchange appeared to be secondary to the associated hypertriglyceridaemia and the related changes in distribution of phospholipids between classes of plasma lipoproteins. PMID:1536661

  6. Determination of separate kidney clearance by means of the Tc-DTPA complex and the scintillation camera

    International Nuclear Information System (INIS)

    Piepsz, A.; Dobbeleir, A.; Erbsmann, F.

    1975-01-01

    A new quantitative method to determine the separate kidney is described. This method is based on the use of the Tc-DTPA complex administered in a single intraveinous injection, a scintillation camera and continuous computerized data recording for 20 minutes at 20 sec. intervals. By definition the slope of the kidney radioactivity curve, divided by the corresponding plasma concentration, represents at each instant the glomerular clearance of the kidney. This only applies before the 3rd minute following the intraveinous tracer injection, when the filtered radioactivity has not yet left the kidney area. Between the 60th and 180th sec., 6 clearance values may be determined for each kidney. For each 20-sec. time interval the renal activity increase per minute is divided by the plasma concentration during the same interval and the average of these values is taken as the glomerular clearance figure. Some results have been analysed. The test could end 3 min. after the intraveinous injection. Continuation of the recording for 20 min. gives a complete dynamic picture of the kidney function [fr

  7. Improved drainage with active chest tube clearance.

    Science.gov (United States)

    Shiose, Akira; Takaseya, Tohru; Fumoto, Hideyuki; Arakawa, Yoko; Horai, Tetsuya; Boyle, Edward M; Gillinov, A Marc; Fukamachi, Kiyotaka

    2010-05-01

    This study was performed to evaluate the efficacy of a novel chest drainage system. This system employs guide wire-based active chest tube clearance to improve drainage and maintain patency. A 32 Fr chest tube was inserted into pleural cavities of five pigs. On the left, a tube was connected to the chest canister, and on the right, the new system was inserted between the chest tube and chest canister. Acute bleeding was mimicked by periodic infusion of blood. The amount of blood drained from each chest cavity was recorded every 15 min for 2 h. After completion of the procedure, all residual blood and clots in each chest cavity were assessed. The new system remained widely patent, and the amount of drainage achieved with this system (670+/-105 ml) was significantly (P=0.01) higher than that with the standard tube (239+/-131 ml). The amount of retained pleural blood and clots with this system (150+/-107 ml) was significantly (P=0.04) lower than that with the standard tube (571+/-248 ml). In conclusion, a novel chest drainage system with active tube clearance significantly improved drainage without tube manipulations. 2010 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. Macrophage-dependent clearance of systemically administered B16BL6-derived exosomes from the blood circulation in mice

    OpenAIRE

    Imai, Takafumi; Takahashi, Yuki; Nishikawa, Makiya; Kato, Kana; Morishita, Masaki; Yamashita, Takuma; Matsumoto, Akihiro; Charoenviriyakul, Chonlada; Takakura, Yoshinobu

    2015-01-01

    Previous studies using B16BL6-derived exosomes labelled with gLuc–lactadherin (gLuc-LA), a fusion protein of Gaussia luciferase (a reporter protein) and lactadherin (an exosome-tropic protein), showed that the exosomes quickly disappeared from the systemic circulation after intravenous injection in mice. In the present study, the mechanism of rapid clearance of intravenously injected B16BL6 exosomes was investigated. gLuc-LA-labelled exosomes were obtained from supernatant of B16BL6 cells aft...

  9. Abnormal norepinephrine clearance and adrenergic receptor sensitivity in idiopathic orthostatic intolerance

    Science.gov (United States)

    Jacob, G.; Shannon, J. R.; Costa, F.; Furlan, R.; Biaggioni, I.; Mosqueda-Garcia, R.; Robertson, R. M.; Robertson, D.

    1999-01-01

    BACKGROUND: Chronic orthostatic intolerance (OI) is characterized by symptoms of inadequate cerebral perfusion with standing, in the absence of significant orthostatic hypotension. A heart rate increase of >/=30 bpm is typical. Possible underlying pathophysiologies include hypovolemia, partial dysautonomia, or a primary hyperadrenergic state. We tested the hypothesis that patients with OI have functional abnormalities in autonomic neurons regulating cardiovascular responses. METHODS AND RESULTS: Thirteen patients with chronic OI and 10 control subjects underwent a battery of autonomic tests. Systemic norepinephrine (NE) kinetics were determined with the patients supine and standing before and after tyramine administration. In addition, baroreflex sensitivity, hemodynamic responses to bolus injections of adrenergic agonists, and intrinsic heart rate were determined. Resting supine NE spillover and clearance were similar in both groups. With standing, patients had a greater decrease in NE clearance than control subjects (55+/-5% versus 30+/-7%, Pheart rate 25 bpm was lower in patients than in control subjects (0.5+/-0.05 versus 1.0+/-0.1 microg, Pheart rate was similar in both groups. CONCLUSIONS: The decreased NE clearance with standing, resistance to the NE-releasing effect of tyramine, and increased sensitivity to adrenergic agonists demonstrate dramatically disordered sympathetic cardiovascular regulation in patients with chronic OI.

  10. Effect of clonidine on 22Na clearance in the rabbit eye

    International Nuclear Information System (INIS)

    Obenberger, J.; Rozsival, P.; Babicky, A.

    1979-01-01

    Effects of clonidine on the intraocular hydrodynamics demonstrated themselves as changes of 22 Na-clearance. This test is based on the principle of the intraocular penetration of contactly applied radioisotope and on monitoring the decreasing ocular radioactivity by means of external gamma detectors. The half-times of 22 Na-clearance were significantly prolonged after the local application of 100 μl of 0.5% clonidine (Isoglaucon Boehringer) as compared with the control group. The control animals displayed a half-time of 38.0+-2.7 in comparison with the treated animals measured at intervals of 30 to 90 min and 90 to 150 min after drug instillation, where half-times were significantly prolonged to 49.3+-4.3 and 63.4+-3.8, respectively. In other groups of rabbits 22 Na-clearance was measured on the contralateral eyes of after the intravenous injection of clonidine (25 μg per kg). In both cases the half-times did not significantly differ from the values found in controls. The observed changes of ocular hydrodynamics caused by clonidine probably reflect the inhibitory influence of this drug on aqueous humour production. Results of present investigations point to the decisive role of the local action of clonidine on the eye. (author)

  11. Effects of cigarette smoking on iodine 123 N-isopropyl-f-iodoamphetamine clearance from the lung

    International Nuclear Information System (INIS)

    Kato, Kunihiko; Harada, Satoshi; Takahashi, Tsuneo; Katsuragawa, Shigehiko; Yanagisawa, Toru

    1991-01-01

    Iodine 123 N-isopropyl-p-iodoamphetamine ( 123 I-IMP), originally developed as a brain scanning agent, is also taken up by the lung. To evaluate the effects of cigarette smoking on the kinetics of IMP in the lung, we studied 123 I-IMP clearance from the lung in 18 volunteers (8 non-smokers and 10 smokers). After the injection of 111 MBq of 123 I-IMP into the medial cubital vein, the time-activity curve for 60 min and the regional activity using 1 frame per minute and a 64x64 matrix were obtained. The 123 I-IMP clearance curve was described as follows: C(t)=A 1 e ( -k 1 t)+A 2 e ( -k 2 t)(A 1 , A 2 : intercepts, and k 1 , k 2 : slopes of the exponential components). 123 I-IMP clearance was delayed in smokers, and k 2 was smaller in smokers. Also, a correlation between k 1 , k 2 , and the number of cigarettes smoked per day was found (r=-0.65, r=-0.74, respectively, P 123 I-IMP in the lung indicate lung metabolic disorders due to cigarette smoking. (orig.)

  12. Fate of tumor cells injected into left ventricle of heart in BALB/c mice: role of natural killer cells

    DEFF Research Database (Denmark)

    Basse, P; Hokland, P; Heron, I

    1988-01-01

    The arrest, retention, and elimination (i.e., clearance) of radiolabeled YAC-1 lymphoma cells injected either iv or into the left ventricle (LV) of the heart were studied in male BALB/c mice, with special emphasis on the role of natural killer (NK) cells. After iv injection YAC-1 cells were...

  13. Dosimetric implications of the infiltrated injection

    International Nuclear Information System (INIS)

    Castronovo, F.P.; McKusick, K.A.; Strauss, H.W.

    1984-01-01

    Following inadvertent infiltration of a radiopharmaceutical, there is variable and uncertain uptake in target tissue. Concomitantly, there is also a concern for the radiation dose to the infiltrated site. This investigation determined the clearance and radiation burdens from various radiopharmaceutical infiltrates in a rat model. Nine separate sites were studied for: Tc-99m microspheres; Tc-99m MDP; Ga-67 citrate; and Tl-201 chloride. Following sc injection on the shaven posteriors of anesthetized adult male Sprague-Dawley rats, gamma camera and computer data were collected up to 24 hours. The resulting data were expressed semilogarithmically as the mean (N = 9) of the ''% retained at site'' as a f(time) after injection. Nonparticulate agents showed a tri-exponential release pattern from each site, whereas the microspheres remained for an extended period of time. Using these pharma-cokinetic curves, the % remaining at each site for various times, and rems/mCi per lcc infiltrate was determined

  14. A High Throughput, 384-Well, Semi-Automated, Hepatocyte Intrinsic Clearance Assay for Screening New Molecular Entities in Drug Discovery.

    Science.gov (United States)

    Heinle, Lance; Peterkin, Vincent; de Morais, Sonia M; Jenkins, Gary J; Badagnani, Ilaria

    2015-01-01

    A high throughput, semi-automated clearance screening assay in hepatocytes was developed allowing a scientist to generate data for 96 compounds in one week. The 384-well format assay utilizes a Thermo Multidrop Combi and an optimized LC-MS/MS method. The previously reported LCMS/ MS method reduced the analytical run time by 3-fold, down to 1.2 min injection-to-injection. The Multidrop was able to deliver hepatocytes to 384-well plates with minimal viability loss. Comparison of results from the new 384-well and historical 24-well assays yielded a correlation of 0.95. In addition, results obtained for 25 marketed drugs with various metabolism pathways had a correlation of 0.75 when compared with literature values. Precision was maintained in the new format as 8 compounds tested in ≥39 independent experiments had coefficients of variation ≤21%. The ability to predict in vivo clearances using the new stability assay format was also investigated using 22 marketed drugs and 26 AbbVie compounds. Correction of intrinsic clearance values with binding to hepatocytes (in vitro data) and plasma (in vivo data) resulted in a higher in vitro to in vivo correlation when comparing 22 marketed compounds in human (0.80 vs 0.35) and 26 AbbVie Discovery compounds in rat (0.56 vs 0.17), demonstrating the importance of correcting for binding in clearance studies. This newly developed high throughput, semi-automated clearance assay allows for rapid screening of Discovery compounds to enable Structure Activity Relationship (SAR) analysis based on high quality hepatocyte stability data in sufficient quantity and quality to drive the next round of compound synthesis.

  15. Improved tumor imaging with radiolabeled monoclonal antibodies by plasma clearance with anti-antibody column

    International Nuclear Information System (INIS)

    Lear, J.L.; Kasliwal, R.; Feyerabend, A.; Bunn, P.; Dienhart, D.G.; Johnson, T.K.; Glenn, S.D.; Maddock, S.W.

    1990-01-01

    This paper reports on imaging of tumors with use of radiolabeled monoclonal antibodies (MoAs) that often hindered by high levels of background activity. The ability to lower blood pool MoA activity at a selected time after injection offers a potential method to reduce background while preserving tumor uptake. Toward this goal, the authors investigated the process of clearing MoA from patients' plasma with use of an anti-antibody column. One patient with breast cancer and four with lung cancer were given intravenous injection of 5 mCi of indium-111 KC4 (Coulter Immunology) and imaged at 20, 24, 48, and 72 hours with use of a whole-body canner coupled to a computer. Plasma clearance was performed between the 20- and 24-hour images with use of a COBEIA system. Images were inspected visually and analyzed by region-of-interest quantification

  16. Cerebrospinal Fluid Clearance in Alzheimer Disease Measured with Dynamic PET.

    Science.gov (United States)

    de Leon, Mony J; Li, Yi; Okamura, Nobuyuki; Tsui, Wai H; Saint-Louis, Les A; Glodzik, Lidia; Osorio, Ricardo S; Fortea, Juan; Butler, Tracy; Pirraglia, Elizabeth; Fossati, Silvia; Kim, Hee-Jin; Carare, Roxana O; Nedergaard, Maiken; Benveniste, Helene; Rusinek, Henry

    2017-09-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribriform plate, human CSF clearance pathways are not well characterized. Dynamic PET with 18 F-THK5117, a tracer for tau pathology, was used to estimate the ventricular CSF time-activity as a biomarker for CSF clearance. We tested 3 hypotheses: extracranial CSF is detected at the superior turbinates; CSF clearance is reduced in AD; and CSF clearance is inversely associated with amyloid deposition. Methods: Fifteen subjects, 8 with AD and 7 normal control volunteers, were examined with 18 F-THK5117. Ten subjects additionally underwent 11 C-Pittsburgh compound B ( 11 C-PiB) PET scanning, and 8 were 11 C-PiB-positive. Ventricular time-activity curves of 18 F-THK5117 were used to identify highly correlated time-activity curves from extracranial voxels. Results: For all subjects, the greatest density of CSF-positive extracranial voxels was in the nasal turbinates. Tracer concentration analyses validated the superior nasal turbinate CSF signal intensity. AD patients showed ventricular tracer clearance reduced by 23% and 66% fewer superior turbinate CSF egress sites. Ventricular CSF clearance was inversely associated with amyloid deposition. Conclusion: The human nasal turbinate is part of the CSF clearance system. Lateral ventricle and superior nasal turbinate CSF clearance abnormalities are found in AD. Ventricular CSF clearance reductions are associated with increased brain amyloid depositions. These data suggest that PET-measured CSF clearance is a biomarker of potential interest in AD and other neurodegenerative diseases. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  17. Comparison of clearance and arteriovenous extraction techniques for measurements of renal hemodynamic functions

    International Nuclear Information System (INIS)

    Katzberg, R.W.; Pabico, R.C.; Morris, T.W.; Hayakawa, K.; McKenna, B.A.; Ventura, J.A.; Fischer, H.W.

    1986-01-01

    No previous studies have directly compared timed urine collections (UV/P) vs. arteriovenous (A-V) extraction methods for determination of renal function in whole kidney preparations. We examined different markers and techniques for assessing renal plasma flow (RPF), filtration fraction (FF), and glomerular filtration rate (GFR) in both steady-state and rapidly changing conditions following 2 ml/kg bolus intravenous injections of either Renografin 76% (meglumine/sodium diatrizoate-76%) or hypertonic mannitol 25%. During steady-state conditions, excellent correlations were obtained when comparing markers and techniques. Thus, timed urinary clearances of inulin vs. 99m-technetium DTPA (Tc) had a correlation coefficient (R) of .96 (P less than .01; n = 16), and the A-V extraction technique of inulin vs. Tc as determinants of GFR showed a correlation of R = .98 (P less than .01; n = 15). The timed urinary clearance of inulin vs. the A-V extraction of inulin for glomerular filtration gave a correlation of R = .93 (P less than .01; n = 15). The clearance of para-aminohippurate (PAH) divided by the extraction of PAH vs. flow determinations using the electromagnetic flowmeter gave a correlation of R = .92 (P less than .01; n = 16). The anticipated decrease in GFR following contrast medium and hypertonic mannitol was observed using the A-V extraction technique, whereas an artifactual, exaggerated increase in GFR was observed using the timed urine collection technique. Similarly, we noted an exaggerated increase in RPF using CPAH/EPAH as the methodology. We conclude that rapid changes in renal hemodynamics may be measured accurately using the A-V extraction technique but not with clearance techniques requiring timed urine collections

  18. Validation of Dose Calculation Codes for Clearance

    International Nuclear Information System (INIS)

    Menon, S.; Wirendal, B.; Bjerler, J.; Studsvik; Teunckens, L.

    2003-01-01

    Various international and national bodies such as the International Atomic Energy Agency, the European Commission, the US Nuclear Regulatory Commission have put forward proposals or guidance documents to regulate the ''clearance'' from regulatory control of very low level radioactive material, in order to allow its recycling as a material management practice. All these proposals are based on predicted scenarios for subsequent utilization of the released materials. The calculation models used in these scenarios tend to utilize conservative data regarding exposure times and dose uptake as well as other assumptions as a safeguard against uncertainties. None of these models has ever been validated by comparison with the actual real life practice of recycling. An international project was organized in order to validate some of the assumptions made in these calculation models, and, thereby, better assess the radiological consequences of recycling on a practical large scale

  19. Antibody deposition in tumor in relation to blood clearance using a nephrectomized mouse model

    International Nuclear Information System (INIS)

    Nelp, W.B.; Eary, J.F.; Beaumier, P.; Krohn, K.A.; Hellstrom, K.E.; Hellstrom, I.

    1985-01-01

    The purpose of this experiment was to study tumor deposition of monoclonal anti-p97 melanoma antibody (Fab) as a function of its blood concentration over time. I-131-anti-p97 Fab and I-125 non-specific Fab were injected I.V. into 28 control athymic (nude) mice (CM) bearing human xenografted malignant melanoma containing p-97 antigen. Fab (M.W. 50,000) is rapidly excreted by kidney and >90% excretion occurred in 24 hr. To create maximum sustained high blood concentrations of Fab 10 similar mice were likewise injected 1 hr after acute nephrectomy (NM). In this case 24 hr. body excretion was <1%. Blood clearance in CM was biexponential with initial T-1/2 0.4 hr. (80%) a second T-1/2 of 4.4 hr. In NM clearance was monoexponential with a T-1/2 of 29.6 hr. Blood concentrations at 4 hrs. were 2 vs. 19% dose/gm (CM vs NM) and 0.15 vs 12 at 24 hrs. This tumor binding resembled a 2nd order phenomenon. Such information may be useful in predicting the effect of dosage manipulations (multiple bolus or sustained infusions) designed to increase Fab blood levels and enhance tumor labeling with Fab. The NM model should be useful to study the kinetics of antibody tumor deposition with various antibodies

  20. Renal clearance of an ionic high-osmolar and a nonionic low-osmolar contrast medium

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Vestergaard, A.; Nielsen, S.L.; Fogh-Andersen, N.; Golman, K.; Dorph, S.

    1991-01-01

    One hundred patients with normal serum creatinine concentration underwent intravenous urography with either an ionic high-osmolar (diatrizoate) or a nonionic low-osmolar (iopamidol) contrast medium after randomization. Before injection of the contrast medium, a blood sample was drawn for determinating serum creatinine concentration, and a urine sample for measurement of urine osmolality. Using x-ray fluorescence, the plasma concentration of iodine (contrast medium) was determined on blood samples drawn approximately 3 and 4 hours after injection of the contrast medium. The glomerular filtration rate was calculated by two different formulas: one requiring only a single sample and one requiring at least two samples (standard). There were poor correlations between the standard contrast medium clearance and the serum creatinine concentration, the estimated creatinine clearance (calculated from a nomogram), as well as the urine osmolality. The 3-hour and the 4-hour single-sample values correlated well with the two-sample values for both contrast media. In patients with normal serum creatinine, the glomerular filtration rate determined by measuring the contrast medium concentration in a single plasma sample obtained at 3 hours, is almost identical to the value determined from two samples. Consequently, two samples are unnecessary

  1. Biodistribution and Clearance of Stable Superparamagnetic Maghemite Iron Oxide Nanoparticles in Mice Following Intraperitoneal Administration

    Directory of Open Access Journals (Sweden)

    Binh T. T. Pham

    2018-01-01

    Full Text Available Nanomedicine is an emerging field with great potential in disease theranostics. We generated sterically stabilized superparamagnetic iron oxide nanoparticles (s-SPIONs with average core diameters of 10 and 25 nm and determined the in vivo biodistribution and clearance profiles. Healthy nude mice underwent an intraperitoneal injection of these s-SPIONs at a dose of 90 mg Fe/kg body weight. Tissue iron biodistribution was monitored by atomic absorption spectroscopy and Prussian blue staining. Histopathological examination was performed to assess tissue toxicity. The 10 nm s-SPIONs resulted in higher tissue-iron levels, whereas the 25 nm s-SPIONs peaked earlier and cleared faster. Increased iron levels were detected in all organs and body fluids tested except for the brain, with notable increases in the liver, spleen, and the omentum. The tissue-iron returned to control or near control levels within 7 days post-injection, except in the omentum, which had the largest and most variable accumulation of s-SPIONs. No obvious tissue changes were noted although an influx of macrophages was observed in several tissues suggesting their involvement in s-SPION sequestration and clearance. These results demonstrate that the s-SPIONs do not degrade or aggregate in vivo and intraperitoneal administration is well tolerated, with a broad and transient biodistribution. In an ovarian tumor model, s-SPIONs were shown to accumulate in the tumors, highlighting their potential use as a chemotherapy delivery agent.

  2. Allometric scaling for predicting human clearance of bisphenol A

    Energy Technology Data Exchange (ETDEWEB)

    Collet, Séverine H., E-mail: s.collet@envt.fr; Picard-Hagen, Nicole, E-mail: n.hagen-picard@envt.fr; Lacroix, Marlène Z., E-mail: m.lacroix@envt.fr; Puel, Sylvie, E-mail: s.puel@envt.fr; Viguié, Catherine, E-mail: c.viguie@envt.fr; Bousquet-Melou, Alain, E-mail: a.bousquet-Melou@envt.fr; Toutain, Pierre-Louis, E-mail: pltoutain@wanadoo.fr; Gayrard, Véronique, E-mail: v.gayrard@envt.fr

    2015-05-01

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady state volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min.

  3. Clearance of building structures for conventional non-nuclear reuse

    International Nuclear Information System (INIS)

    Buss, K.; Boehringer, S.

    1998-01-01

    At the example of a fuel assembly plant the strategy of control measurements on building surfaces, which shall be conventionally reused after their clearance, is regarded. Based on the given clearance levels the used measuring methods, especially with regard of possibly covered or intruded uranium contamination, are shown. The possibility of using the in-situ-γ-spectroscopy is discussed. (orig.) [de

  4. Discrepancy between circadian rhythms of inulin and creatinine clearance

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; Krediet, R. T.; Arisz, L.

    1992-01-01

    To elucidate the disparity between circadian rhythmicity of inulin and creatinine clearance, we simultaneously measured inulin and creatinine clearances every 3 hours during 1 day in 14 normal subjects and in 8 patients with nephrotic syndrome. All patients and normal subjects had a circadian rhythm

  5. 20 CFR 655.150 - Interstate clearance of job order.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  6. 78 FR 77027 - Overhead Clearance (Air-Draft) Accidents

    Science.gov (United States)

    2013-12-20

    ... No. USCG-2013-0466] Overhead Clearance (Air-Draft) Accidents AGENCY: Coast Guard, DHS. ACTION... clearance (air-draft) accidents. In its petition, which calls for vessel masters to be provided with... accidents that it says were avoidable and that resulted in damage to or destruction of waterway...

  7. 48 CFR 1432.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  8. 48 CFR 32.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  9. 48 CFR 832.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  10. Allometric scaling for predicting human clearance of bisphenol A

    International Nuclear Information System (INIS)

    Collet, Séverine H.; Picard-Hagen, Nicole; Lacroix, Marlène Z.; Puel, Sylvie; Viguié, Catherine; Bousquet-Melou, Alain; Toutain, Pierre-Louis; Gayrard, Véronique

    2015-01-01

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady state volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min

  11. Clearance systems in the brain—implications for Alzheimer disease

    Science.gov (United States)

    Tarasoff-Conway, Jenna M.; Carare, Roxana O.; Osorio, Ricardo S.; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V.; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J.

    2015-01-01

    Accumulation of toxic protein aggregates—amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles—is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood–brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ. PMID:26195256

  12. Clearance systems in the brain-implications for Alzheimer disease.

    Science.gov (United States)

    Tarasoff-Conway, Jenna M; Carare, Roxana O; Osorio, Ricardo S; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J

    2015-08-01

    Accumulation of toxic protein aggregates-amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles-is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood-brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ.

  13. Intercalibration of mussel Mytilus edulis clearance rate measurements

    NARCIS (Netherlands)

    Kjerulf Petersen, J.; Bougrier, S.; Smaal, A.C.; Garen, P.; Robert, S.; Larsen, J.E.N.; Brummelhuis, E.B.M.

    2004-01-01

    Clearance rate (CR) was measured in blue mussels Mytilus edulis L. from Aiguillon Bay and the Oosterschelde using 3 different methods: the flow-through method, the bio-deposition method and the indirect or clearance method. CR differed significantly as a function of the method used and of the origin

  14. 32 CFR 644.522 - Clearance of military scrap.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of military scrap. 644.522 Section 644... Excess Land and Improvements § 644.522 Clearance of military scrap. Military scrap can contain or be... destruction, by using command, of all military scrap and scrap metal from lands suitable for cultivation or...

  15. Factors affecting lower calyceal stone clearance after Extracorporeal ...

    African Journals Online (AJOL)

    shanker

    have been identified [1,3]. These include stone characteristics, the type of lithotripter used, LPC anatomy and body habitus. For iso- lated LPC stones, the pelvicalyceal angle, infundibulum length and width are considered important determinants for stone clearance. The impact of body habitus on stone clearance has so far ...

  16. Estimation of 131I hippuran clearance during pregnancy

    International Nuclear Information System (INIS)

    Voigt, R.; Stoll, W.; Zenner, I.; Arndt, J.; Friedrich-Schiller-Univ., Jena

    1979-01-01

    Changes in 131 I hippuran clearance were estimated by a non-catheter method, as well as total clearance and clearance of each kidney, in 43 women at various stages of pregnancy and in 13 non-pregnant women who were not using hormonal contraceptives. The results are demonstrated in graph form. The methods used are described in detail. The procedure for determining clearance in separate kidneys is indicated. It was found that clearance values increased up to the 35th and 26th weeks of pregnancy. The difference between the sides that were found corresponds with the previously known difference in the function of the right and left kidneys and ureters. (orig.) [de

  17. Analysis of conservativity analysis for clearance levels. Final report

    International Nuclear Information System (INIS)

    Deckert, A.; Thierfeldt, S.

    1997-07-01

    When deriving clearance levels for material from nuclear installations it is necessary to proceed with a certain degree of conservativity. This can, however, differ between various sets of clearance levels leading to inconsistencies between clearance pathways. The aim of the work therefore is to compare levels of conservativity for the following two sets of clearance levels: clearance levels for disposal as conventional waste and for metallic materials for recycling/reuse. A method was developed to quantify the degree of conservativity and make it comparable. The actual and future situation for disposal of (conventional) wastes in Germany was analysed. In addition, the masses, nuclide vectors, geographical distribution etc. for slightly radioactive material being cleared for conventional disposal was analysed and modelled and the resulting dose distributions were calculated. The values for the clearance levels were taken from the 1995 recommendation by the German Commission on Radiation Protection (SSK). By using realistic scenarios, the exposure was calculated for the personnel on the landfills and for persons of the general public being exposed via groundwater pathways. It could be shown that the trivial dose range will not be exceeded even if the masses of cleared material per landfill site exceed 100 Mg/a. Because of the types and distribution of nuclear installations in Germany and because of the nuclide vectors it is therefore not necessary to limit the masses per landfill sites. Clearance levels that are determined by the exposure pathways external exposure to and the inhalation of dust by the landfill personnel show a similar level of conservativity as those for metal scrap. This means that the clearance levels for gamma emitting nuclides are not overly restrictive. Although radiologically justified, raising the clearance levels would not lead to an increase of the material quantities because other nuclides of the respective nuclide vectors are limiting. In

  18. A model of clearance rate regulation in mussels

    Science.gov (United States)

    Fréchette, Marcel

    2012-10-01

    Clearance rate regulation has been modelled as an instantaneous response to food availability, independent of the internal state of the animals. This view is incompatible with latent effects during ontogeny and phenotypic flexibility in clearance rate. Internal-state regulation of clearance rate is required to account for these patterns. Here I develop a model of internal-state based regulation of clearance rate. External factors such as suspended sediments are included in the model. To assess the relative merits of instantaneous regulation and internal-state regulation, I modelled blue mussel clearance rate and growth using a DEB model. In the usual standard feeding module, feeding is governed by a Holling's Type II response to food concentration. In the internal-state feeding module, gill ciliary activity and thus clearance rate are driven by internal reserve level. Factors such as suspended sediments were not included in the simulations. The two feeding modules were compared on the basis of their ability to capture the impact of latent effects, of environmental heterogeneity in food abundance and of physiological flexibility on clearance rate and individual growth. The Holling feeding module was unable to capture the effect of any of these sources of variability. In contrast, the internal-state feeding module did so without any modification or ad hoc calibration. Latent effects, however, appeared transient. With simple annual variability in temperature and food concentration, the relationship between clearance rate and food availability predicted by the internal-state feeding module was quite similar to that observed in Norwegian fjords. I conclude that in contrast with the usual Holling feeding module, internal-state regulation of clearance rate is consistent with well-documented growth and clearance rate patterns.

  19. Delivery of antifibroblast agents as adjuncts to filtration surgery. Part I--Periocular clearance of cobalt-57 bleomycin in experimental drug delivery: pilot study in the rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Kay, J.S.; Litin, B.S.; Woolfenden, J.M.; Chvapil, M.; Herschler, J.

    1986-10-01

    Antitumor and antifibroblast agents show promise as adjuncts after glaucoma filtration surgery in reducing postoperative scarring and failure. We used nuclear imaging in rabbits to investigate periocular clearance of one such agent (/sup 57/Co-bleomycin). Sub-Tenon injection was compared to other delivery techniques. Our results showed that a collagen sponge and a silastic disc implant with a microhole prolonged drug delivery when compared to sub-Tenon injection alone or injection with a viscosity enhancing agent (0.5% sodium hyaluronate). We theorize that if an antifibroblast agent can be delivered in small and sustained amounts after filtration surgery, this may prolong bleb longevity and avoid unnecessary drug toxicity.

  20. Delivery of antifibroblast agents as adjuncts to filtration surgery. Part I--Periocular clearance of cobalt-57 bleomycin in experimental drug delivery: pilot study in the rabbit

    International Nuclear Information System (INIS)

    Kay, J.S.; Litin, B.S.; Woolfenden, J.M.; Chvapil, M.; Herschler, J.

    1986-01-01

    Antitumor and antifibroblast agents show promise as adjuncts after glaucoma filtration surgery in reducing postoperative scarring and failure. We used nuclear imaging in rabbits to investigate periocular clearance of one such agent ( 57 Co-bleomycin). Sub-Tenon injection was compared to other delivery techniques. Our results showed that a collagen sponge and a silastic disc implant with a microhole prolonged drug delivery when compared to sub-Tenon injection alone or injection with a viscosity enhancing agent (0.5% sodium hyaluronate). We theorize that if an antifibroblast agent can be delivered in small and sustained amounts after filtration surgery, this may prolong bleb longevity and avoid unnecessary drug toxicity

  1. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... Background: Of the estimated 384,000 needle-stick injuries occurring in hospitals each year, 23% occur in surgical settings. This study was conducted to assess safe injection procedures, injection practices, and circumstances contributing to needlestick and sharps injures (NSSIs) in operating rooms.

  2. Induced dural lymphangiogenesis facilities soluble amyloid-beta clearance from brain in a transgenic mouse model of Alzheimer's disease

    Directory of Open Access Journals (Sweden)

    Ya-Ru Wen

    2018-01-01

    Full Text Available Impaired amyloid-β clearance from the brain is a core pathological event in Alzheimer's disease. The therapeutic effect of current pharmacotherapies is unsatisfactory, and some treatments cause severe side effects. The meningeal lymphatic vessels might be a new route for amyloid-β clearance. This study investigated whether promoting dural lymphangiogenesis facilitated the clearance of amyloid-β from the brain. First, human lymphatic endothelial cells were treated with 100 ng/mL recombinant human vascular endothelial growth factor-C (rhVEGF-C protein. Light microscopy verified that rhVEGF-C, a specific ligand for vascular endothelial growth factor receptor-3 (VEGFR-3, significantly promoted tube formation of human lymphatic endothelial cells in vitro. In an in vivo study, 200 μg/mL rhVEGF-C was injected into the cisterna magna of APP/PS1 transgenic mice, once every 2 days, four times in total. Immunofluorescence staining demonstrated high levels of dural lymphangiogenesis in Alzheimer's disease mice. One week after rhVEGF-C administration, enzyme-linked immunosorbent assay results showed that levels of soluble amyloid-β were decreased in cerebrospinal fluid and brain. The Morris water maze test demonstrated that spatial cognition was restored. These results indicate that the upregulation of dural lymphangiogenesis facilities amyloid-β clearance from the brain of APP/PS1 mice, suggesting the potential of the VEGF-C/VEGFR-3 signaling pathway as a therapeutic target for Alzheimer's disease.

  3. Determination of hepatic fractional clearance of radioactive gold colloids for a measure of effective hepatic blood flow

    International Nuclear Information System (INIS)

    Fujii, Masahiro

    1979-01-01

    For a measure of effective blood flow, a hepatic fractional clearance of 198 Au-colloids was determined, which was obtained from the disappearance rate multiplied by the fraction of injected dose taken up by the liver. The hepatic uptake was determined with a gamma camera. The counts over the liver was corrected for body weight and height. The method was considered sufficiently simple for routine use. 198 Au-colloids were obtained from Dainabot Lab. and CIS. The former gave 64% higher values of disappearance rate than the latter, without any change in the organ distribution. A quality control tests were applied over a six-year period to the disappearance rates. Reproducibility within 95 to confidence limits was found for both groups. In 28 normal control subjects, hepatic fractional clearance of the colloids from Dainabot Lab. was 18.5 +- 3.4%/min. In patients with progressed hepatic disease, both hepatic fractional clearance and final hepatic uptake were decreased, showing that the determination of hepatic uptake is necessary in measuring effective hepatic blood flow by the colloidal clearance method. The influence of splenic uptake is discussed in relation to hepatic blood flow measurement. (author)

  4. Altered Tracer Distribution and Clearance in the Extracellular Space of the Substantia Nigra in a Rodent Model of Parkinson's Disease

    Directory of Open Access Journals (Sweden)

    Yuan Fang

    2017-07-01

    Full Text Available The relationship between extracellular space (ECS diffusion parameters and brain drug clearance is not well-studied, especially in the context of Parkinson's disease (PD. Therefore, we used a rodent model of PD to explore the distribution and clearance of a magnetic resonance tracer. Forty male Sprague Dawley rats were randomized into four different groups: a PD group, a Madopar group (PD + Madopar treatment, a sham group, and a control group. All rats received an injection of the extracellular tracer gadolinium-diethylene triaminepentacetic acid (Gd-DTPA directly into the substantia nigra (SN. ECS diffusion parameters including the effective diffusion coefficient (D*, clearance coefficient (k', ratio of the maximum distribution volume of the tracer (Vd-max%, and half-life (t1/2 were measured. We found that all parameters were significantly increased in the PD group compared to the other three groups (D*: F = 5.774, p = 0.0025; k': F = 20.00, P < 0.0001; Vd-max%: F = 12.81, P < 0.0001; and t1/2: F = 23.35, P < 0.0001. In conclusion, the PD group exhibited a wider distribution and lower clearance of the tracer compared to the other groups. Moreover, k' was more sensitive than D* for monitoring morphological and functional changes in the ECS in a rodent model of PD.

  5. Creatinine clearance during cimetidine administration for measurement of glomerular filtration rate

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; de Waart, D. R.; Arisz, L.

    1992-01-01

    Creatinine clearance inaccurately estimates true glomerular filtration rate (GFR) because of tubular secretion of creatinine. We studied the ability of oral cimetidine, a blocker of tubular creatinine secretion, to improve the accuracy of measuring creatinine clearance. Clearances of inulin and

  6. 76 FR 59379 - Proposed Information Collection; Comment Request; Generic Clearance for Research in Development...

    Science.gov (United States)

    2011-09-26

    ...-XXXX. Type of Review: Generic Clearance Request. Title: Generic Clearance for Research in Development... information collected through qualitative evaluation methods will inform the disclosure form's design and... Proposed Information Collection; Comment Request; Generic Clearance for Research in Development of...

  7. Nuclear regulation. NRC's security clearance program can be strengthened

    International Nuclear Information System (INIS)

    Fultz, Keith O.; Kruslicky, Mary Ann; Bagnulo, John E.

    1988-12-01

    Because of the national security implications of its programs, the Nuclear Regulatory Commission (NRC) investigates the background of its employees and consultants as well as others to ensure that they are reliable and trustworthy. If the investigation indicates that an employee will not endanger national security, NRC grants a security clearance that allows access to classified information, material, and facilities. NRC also requires periodic checks for some clearance holders to ensure their continued clearance eligibility. The Chairman, Subcommittee on Environment, Energy, and Natural Resources, House Committee on Government Operations, asked GAO to review NRC's personnel security clearance program and assess the procedures that NRC uses to ensure that those who operate nuclear power plants do not pose a threat to the public. The Atomic Energy Act of 1954 requires NRC to conduct background investigations of its employees and consultants as well as others who have access to classified information, material, or facilities. To do this, NRC established a personnel security clearance program. Under NRC policies, a security clearance is granted after the Office of Personnel Management (OPM) or the Federal Bureau of Investigation checks the background of those applying for an NRC clearance. NRC also periodically reassesses the integrity of those holding the highest level clearance. NRC employees, consultants, contractors, and licensees as well as other federal employees hold approximately 10,600 NRC clearances. NRC does not grant clearances to commercial nuclear utility employees unless they require access to classified information or special nuclear material. However, the utilities have voluntarily established screening programs to ensure that their employees do not pose a threat to nuclear plants. NRC faces a dilemma when it hires new employees. Although its policy calls for new hires to be cleared before they start work, the security clearance process takes so long

  8. Secretin enhances [14C]erythritol clearance in unanesthetized dogs

    International Nuclear Information System (INIS)

    Lewis, M.H.; Baker, A.L.; Dhorajiwala, J.; Moossa, A.R.

    1982-01-01

    To determine the effect of secretin infusion on clearance of inert markers into bile, unanesthetized dogs fitted with Thomas cannulas received continuous infusions of [ 14 C]erythritol and [ 3 H]inulin throughout study. Taurocholic acid administered sequentially at 9.0, 20.0, and 40.0 mumol/min enhanced [ 14 C]erythritol clearance, and GIH secretin (3 units/min) administered along with TCA (40.0 mumol/min) increased [ 14 C]erythritol clearance from 4.9 +/- 1.2 ml/10 min to 6.8 +/- 1.3 ml/10 min (P less than 0.001), but simultaneously measured [ 3 H]inulin clearance was unaltered. Secretin alone also increased [ 14 C]erythritol clearance but did not alter [ 3 H]inulin clearance. The increase in [ 14 C]erythritol clearance per unit increase in bile flow was less during secretin infusion than TCA. Thus, secretin increases [ 14 C]erythritol transport through restricted channels, probably distal to the canaliculi. [ 14 C]Erythritol may not be an accurate marker for canalicular bile flow in dogs during secretin infusion

  9. Dynamic modelling and experimental study of cantilever beam with clearance

    International Nuclear Information System (INIS)

    Li, B; Jin, W; Han, L; He, Z

    2012-01-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  10. Dynamic modelling and experimental study of cantilever beam with clearance

    Science.gov (United States)

    Li, B.; Jin, W.; Han, L.; He, Z.

    2012-05-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  11. Sodium Ferric Gluconate Injection

    Science.gov (United States)

    Sodium ferric gluconate injection is used to treat iron-deficiency anemia (a lower than normal number of ... are also receiving the medication epoetin (Epogen, Procrit). Sodium ferric gluconate injection is in a class of ...

  12. Calcitonin Salmon Injection

    Science.gov (United States)

    Calcitonin salmon injection is used to treat osteoporosis in postmenopausal women. Osteoporosis is a disease that causes bones to weaken and break more easily. Calcitonin salmon injection is also used to treat Paget's disease ...

  13. Iron Dextran Injection

    Science.gov (United States)

    Iron dextran injection is used to treat iron-deficiency anemia (a lower than normal number of red blood cells ... treated with iron supplements taken by mouth. Iron dextran injection is in a class of medications called ...

  14. Aminocaproic Acid Injection

    Science.gov (United States)

    Aminocaproic acid injection is used to control bleeding that occurs when blood clots are broken down too quickly. This ... the baby is ready to be born). Aminocaproic acid injection is also used to control bleeding in ...

  15. Deoxycholic Acid Injection

    Science.gov (United States)

    Deoxycholic acid injection is used to improve the appearance and profile of moderate to severe submental fat ('double chin'; fatty tissue located under the chin). Deoxycholic acid injection is in a class of medications called ...

  16. Cluster beam injection

    International Nuclear Information System (INIS)

    Bottiglioni, F.; Coutant, J.; Fois, M.

    1978-01-01

    Areas of possible applications of cluster injection are discussed. The deposition inside the plasma of molecules, issued from the dissociation of the injected clusters, has been computed. Some empirical scaling laws for the penetration are given

  17. Antigen injection (image)

    Science.gov (United States)

    Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...

  18. Wind Power and Fault Clearance. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Vikesjoe, Johnny; Messing, Lars (Gothia Power (Sweden))

    2011-04-15

    The increased penetration of wind power will increase the impact of wind power on the grid and thereby increase the importance of a clear guidance concerning the requirements on the protection system of the wind power units and the grid protection in connection to wind power units. The protection system should be able to satisfy the grid connection requirements, set by the TSO (Transmission System Operator) and the grid owners, as well as the general safety and security requirements, such as; personal safety, operational security and economic insurance, i.e. an insurance against economic losses. Vindforsk has appointed Gothia Power AB to perform a study concerning the fault clearance function in connection to wind power installations. The study is divided into two parts; Part 1: The first stage of the project handled the present praxis for the protection, including investigation of legal requirements, operational requirement and personal safety requirement applicable to wind power applications. Proposals for protection requirement for wind power units and the connecting grid are given. Basically 'normal' fault clearance requirements regarding speed, selectivity and redundancy can be used also in applications in connection to wind power. Part 2: The second part of the project results in a guideline for design of protection systems in connection to wind power. In this report mainly part 2 is covered. The main focus is given to clearance of faults in the grid connecting the wind power plants. Regarding internal faults and critical operation states within the wind power plant, a short discussion of feasible protection functions is given. Some critical fault cases in the grid have been identified and discussed: - Undetected islanding and failure of reclosing. There can be a risk of undetected island operation. In such cases it is recommended to use controlled autoreclosing in the vicinity of wind power generation. - Unwanted disconnection of a healthy feeder

  19. UGT polymorphisms and lamotrigine clearance during pregnancy

    DEFF Research Database (Denmark)

    Petrenaite, Vaiva; Öhman, Inger; Ekström, Lena

    2018-01-01

    OBJECTIVE: To evaluate the impact of maternal UGT1A4 and UGT2B7 genetic polymorphisms and sex of foetus on gestation-induced changes in lamotrigine (LTG) clearance during pregnancy and post-partum (PP). METHODS: Single nucleotide polymorphisms UGT1A4 142T > G, L48V (*3), UGT1A4 70C > A, P24T (*2......), and post-partum (PP) as well as the sex of the foetus. RESULTS: Reductions in the LTG concentration-to-dose ratio (C/D ratio) during pregnancy were seen in all genotype panels and varied between -53% and -74% in T3. Genetic polymorphism of UGT1A4 T142G (*3) and UGT2B7 C802T (*2) had the most pronounced.......015) as well as in T3 compared to the heterozygous carriers (802CT) (p = 0.04). Multiple regression analysis demonstrated that women who carried a female foetus had a significantly higher reductions in the LTG C/D ratio from T0 to the end of pregnancy than those with a male foetus (p = 0...

  20. Clearance from the anterior chamber of RBCs from human diabetics

    International Nuclear Information System (INIS)

    Williams, G.A.; Hatchell, D.L.; Collier, B.D.; Knobel, J.

    1984-01-01

    Erythrocytes from diabetic patients manifest decreased deformability and increased adherence. These abnormal membrane properties may diminish the ability of erythrocytes (RBCs) from diabetics to undergo deformation in passage through the trabecular meshwork. Using sodium chromate Cr 51-labeled RBCs from type I diabetic patients with proliferative retinopathy and normal control subjects, we studied RBC clearance from the rabbit anterior chamber. The mean time for 50% clearance (T50) of RBCs from diabetics (76 hours) was significantly longer than that for RBCs from normal subjects (19.5 hours). In this model, RBCs from diabetics have a slower clearance from the anterior chamber than do RBCs from normal subjects

  1. Applicability of Clearance Automatic Laser Inspection System to Clearance Measurement of Concrete Segments

    International Nuclear Information System (INIS)

    Sasaki, M.; Ogino, H.; Hattori, T.

    2009-01-01

    In the decommissioning of a nuclear power plant, large amounts of metal scrap and concrete segments require disposal when dismantling the nuclear reactor and surrounding facilities. When their activity level is negligible or sufficiently small, they can be regarded as general industrial waste. To distinguish between radioactive and nonradioactive materials, the clearance level for each radionuclide has been determined in units of activity concentration. These clearance levels are indicated in the International Atomic Energy Agency (IAEA) Safety Standards Series No. RS-G-1.7. The Japanese regulatory authority decided in 2005 to adopt the values given in RS-G-1.7 as clearance levels in legislation. Recently, a Clearance Automatic Laser Inspection System (CLALIS) has been developed utilizing gamma-ray measurement, automatic laser shape measurement and Monte Carlo calculation. CLALIS comprises four laser scanners and eight large plastic scintillation detectors surrounded by a 5-cm-thick lead shield. Using three-dimensional (3D) laser scanning, a measurement target, which is placed on the measuring tray, is represented as a dot image. The dot image is converted into voxels after noise removal, and is written in MCNP (A General Monte Carlo N-Particle Transport Code System) input files. When the gamma-ray measurement is carried out, the MCNP calculations are also carried out to obtain the calibration factor and background (BG) correction factors. For the clearance measurement of concrete segments, the effect of gamma-rays from natural radionuclides in the measurement target, such as K-40 and the radioactive decay products of Th-232 and U-238, should be taken into account to ensure adequate waste management. Since NE102A plastic scintillation detectors are used for gamma-ray measurement in CLALIS, it is impossible to distinguish between the count rates of natural radionuclides and contaminants on the basis of gamma-ray energy information. To overcome this problem, the

  2. Effect of bile on growth, peritoneal absorption, and blood clearance of Escherichia coli in E coli peritonitis

    International Nuclear Information System (INIS)

    Andersson, R.; Schalen, C.; Tranberg, K.G.

    1991-01-01

    The effect of intraperitoneal bile on growth, peritoneal absorption, and clearance of Escherichia coli was determined in E coli peritonitis in the rat. In E coli peritonitis, intraperitoneal bacterial counts gradually decreased, whereas they increased (after 2 hours) with subsequent development of bacteremia in E coli plus bile peritonitis. After an intraperitoneal injection of labeled bacteria, blood radioactivity was only initially lower in E coli plus bile peritonitis compared with E coli peritonitis. Clearance from blood was lower in E coli plus bile peritonitis than in E coli peritonitis. Organ localization was similar in E coli peritonitis and E coli plus bile peritonitis with decreased splenic, increased pulmonary, and unchanged hepatic uptakes compared with controls. Impaired peritoneal absorption of bacteria, together with impaired local host defense, is likely to enhance the noxious effect of bile in E coli peritonitis

  3. Automated Real-Time Clearance Analyzer (ARCA), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Automated Real-Time Clearance Analyzer (ARCA) addresses the future safety need for Real-Time System-Wide Safety Assurance (RSSA) in aviation and progressively...

  4. Determination of renal clearance of 131I-hippuran

    International Nuclear Information System (INIS)

    Ridzon, S.

    1982-01-01

    The author presents his own method for the determination of total renal clearance of 131 I-hippuran under conditions of its diminishing plasma concentration following single intravenous administration. Total renal clearance is determined as the ratio of the amount of activity excreted into the urine over a certain time interval and of the area limited by the curve of activity decrease in plasma and by the time axis in the corresponding interval. The results are demonstrated in five investigated healthy subjects, and very good agreement of the calculated values of total renal clearance for different time intervals in the same subject is pointed out. When isotope nephrography is simultaneously performed, the method allows to determine also the values of isolated renal clearance for each kidney separately. (author)

  5. IFNL4 affects clearance of hepatitis C virus

    Science.gov (United States)

    Scientists have discovered a new human interferon gene, Interferon Lambda 4 (IFNL4), that affects clearance of the hepatitis C virus. They also identified an inherited genetic variant within IFNL4 that predicts how people respond to treatment for hepatit

  6. Non-destructive clearance measuring in closed joints

    International Nuclear Information System (INIS)

    Doucelance, C.; Manaranche, J.C.

    1976-01-01

    Two methods for clearance measuring in closed joints are described. The first one is based on the mechanical impedance concept, while the other one requires a shock test on shaker. Both are illustrated with an example of application [fr

  7. 77 FR 44641 - Critical Infrastructure Private Sector Clearance Program Request

    Science.gov (United States)

    2012-07-30

    .... DHS Sector Specialists or Protective Security Advisors email the form to the individual who then... clearance request form is signed by both the Federal official who nominated the applicant and the Assistant...

  8. Intraarticular volume and clearance in human synovial effusions

    International Nuclear Information System (INIS)

    Wallis, W.J.; Simkin, P.A.; Nelp, W.B.; Foster, D.M.

    1985-01-01

    Intraarticular volumes were measured by radiolabeled albumin (RISA) distribution in chronic knee effusions from 11 rheumatoid arthritis patients and 9 osteoarthritis patients. Volumes of synovial fluid obtained at joint aspiration were substantially less than those found by RISA dilution. Up to 24 hours was needed for full distribution of RISA throughout the intraarticular compartment. Measured 123I and RISA radioactivity over the knee described monoexponential rate constants, lambda (minute-1). The clearance of 123I and RISA from synovial effusions was derived by the formulation volume (ml) X lambda (minute-1) = clearance (ml/minute). RISA clearance in rheumatoid effusions was significantly greater than that found in osteoarthritis effusions. Intraarticular volume and isotope clearance were easily quantified and provide measures for further evaluating the microvascular physiology of synovial effusions

  9. Airway Clearance Devices for Cystic Fibrosis

    Science.gov (United States)

    2009-01-01

    Executive Summary Objective The purpose of this evidence-based analysis is to examine the safety and efficacy of airway clearance devices (ACDs) for cystic fibrosis and attempt to differentiate between devices, where possible, on grounds of clinical efficacy, quality of life, safety and/or patient preference. Background Cystic fibrosis (CF) is a common, inherited, life-limiting disease that affects multiple systems of the human body. Respiratory dysfunction is the primary complication and leading cause of death due to CF. CF causes abnormal mucus secretion in the airways, leading to airway obstruction and mucus plugging, which in turn can lead to bacterial infection and further mucous production. Over time, this almost cyclical process contributes to severe airway damage and loss of respiratory function. Removal of airway secretions, termed airway clearance, is thus an integral component of the management of CF. A variety of methods are available for airway clearance, some requiring mechanical devices, others physical manipulation of the body (e.g. physiotherapy). Conventional chest physiotherapy (CCPT), through the assistance of a caregiver, is the current standard of care for achieving airway clearance, particularly in young patients up to the ages of six or seven. CF patients are, however, living much longer now than in decades past. The median age of survival in Canada has risen to 37.0 years for the period of 1998-2002 (5-year window), up from 22.8 years for the 5-year window ending in 1977. The prevalence has also risen accordingly, last recorded as 3,453 in Canada in 2002, up from 1,630 in 1977. With individuals living longer, there is a greater need for independent methods of airway clearance. Airway Clearance Devices There are at least three classes of airway clearance devices: positive expiratory pressure devices (PEP), airway oscillating devices (AOD; either handheld or stationary) and high frequency chest compression (HFCC)/mechanical percussion (MP

  10. Experience and lessons learnt from clearance in Germany

    International Nuclear Information System (INIS)

    Thierfeldt, Stefan

    2002-01-01

    Clearance is an important corner-stone of waste management in nuclear installations in Germany. It has been practised successfully for around two decades. The importance of clearance can also be judged from the fact that it has been included detailedly in the new German Radiation Protection Ordinance. Currently, there are 19 NPPs and a number of fuel cycle installations in operation in Germany. The main waste quantities, however, arise from the dismantling of NPPs and fuel cycle installations which are currently in decommissioning. As most of the decommissioning projects are targeted for early dismantling instead of safe enclosure, there is already considerable experience with the application of clearance procedures and verification of clearance levels. The German waste management strategy is governed by two options: Clearance of the material (after decontamination and release measurement). After clearance, the material is no longer regarded as radioactive in a legal sense. Final disposal of the material as radioactive waste in a deep geological repository (no near-surface disposal facilities exist or are planned in Germany). A deep geological repository is planned to be operable around 2030. Stefan Thierfeldt described German clearance requirements and lessons learned from their application to decommissioning of power reactors. The great majority of the waste was in fact recycled, although the costs were dominated by the small fraction that had to be disposed of as radioactive waste. Among the lessons learned from the German experience were some revealing insights into the public perception of both clearance and of recycling of material from decommissioning of a nuclear installation

  11. Cerebrospinal fluid clearance in Alzheimer disease measured with dynamic PET

    DEFF Research Database (Denmark)

    De Leon, Mony J.; Li, Yi; Okamura, Nobuyuki

    2017-01-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribrif......Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing...

  12. Clearance of insoluble dust from the lower respiratory tract

    Energy Technology Data Exchange (ETDEWEB)

    Morrow, P E; Gibb, F R; Johnson, L

    1964-01-01

    Clearance of tagged heavy metal aerosols (Fe, Hg, Mn, Ba, and U) in female beagles by in vivo counting was assessed. Fecal excretion paralleled lower respiratory tract clearance of Fe. No Fe was found in blood, indicating its biological insolubility. Ultrafiltration tests (an indication of biological solubility) ranked the heavy metals as: Hg, Mn, Fe, and U in order of decreasing solubility. The solubility ratios were remarkably similar to the ratios of inverse biological half-times.

  13. A review and comparison of international exemption and clearance levels

    International Nuclear Information System (INIS)

    Cooper, J.R.; Mobbs, S.F.

    1997-01-01

    The publication of new European Basic Safety Standards by the European Commission and of new International Basic Safety Standards by the IAEA together with other international agencies, has led to increased interest in the application of the concepts of exemption and clearance. This paper discusses the derivation of radionuclide-specific exemption and clearance values for application in various areas of the regulation of radioactive materials. (author)

  14. Bronchoscintigraphy and pulmonary clearance of 99mTc-albumin colloid in study of mucociliary clearance

    International Nuclear Information System (INIS)

    Mortensen, Jann

    1998-01-01

    A radioaerosol based method for measuring MC was introduced. It included an inhalation protocol that resulted in a predominant deposition of radioaerosol in the central bronchi and two simple procedures of evaluation: 1) a visual semi-quantitative bronchoscintigraphic analysis, and 2) a quantitative analysis of the retention of the radioactivity at different points after the inhalation. The results showed that bronchoscintigraphy was a simple technique that may be used to visualize a stimulation of mucociliary transport in the central airways of individuals that do not suffer from too much mucus hypersecretion. Comparison of the MC between individuals, however, should preferably be performed by the method of quantitative analysis of the radioactivity disappearance. A change of MC was found to be one of the first detectable effects on lung function of tobacco smoking. It could be effectively detected by measurement of radioaerosol clearance both by bronchoscintigraphy and simple quantification of the MC. The MC may be either acutely enhanced, reduced or not changed by smoking. Long-term smoking impairs MC. The enhancement of MC by β 2 -agonists was very limited in most patients with CF. In the hope of increasing mucus transport in patients with CF, these are treated with various chest physiotherapy techniques. The radioaerosol based method of measurement of MC could assess mucus clearance by chest physiotherapy and cough. (au)

  15. Dynamic characteristics analysis of deployable space structures considering joint clearance

    Science.gov (United States)

    Li, Tuanjie; Guo, Jian; Cao, Yuyan

    2011-04-01

    The clearance in joints influences the dynamic stability and the performance of deployable space structures (DSS). A virtual experimental modal analysis (VEMA) method is proposed to deal with the effects of joint clearance and link flexibility on the dynamic characteristics of the DSS in this paper. The focus is on the finite element modeling of the clearance joint, VEMA and the modal parameters identification of the DSS. The finite element models (FEM) of the clearance joint and the deployable structure are established in ANSYS. The transient dynamic analysis is conducted to provide the time history data of excitation and response for the VEMA. The fast Fourier transform (FFT) technique is used to transform the data from time domain to frequency domain. The frequency response function is calculated to identify the modal parameters of the deployable structure. Experimental verification is provided to indicate the VEMA method is both a cost and time efficient approach to obtain the dynamic characteristics of the DSS. Finally, we analyze the effects of clearance size and gravity on the dynamic characteristics of the DSS. The analysis results indicate that the joint clearance and gravity strongly influence the dynamic characteristics of the DSS.

  16. The tear turnover and tear clearance tests - a review.

    Science.gov (United States)

    Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño

    2018-03-01

    The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.

  17. Domiciliary humidification improves lung mucociliary clearance in patients with bronchiectasis.

    Science.gov (United States)

    Hasani, A; Chapman, T H; McCool, D; Smith, R E; Dilworth, J P; Agnew, J E

    2008-01-01

    Inspired air humidification has been reported to show some benefit in bronchiectatic patients. We have investigated the possibility that one effect might be to enhance mucociliary clearance. Such enhancement might, if it occurs, help to lessen the risks of recurrent infective episodes. Using a radioaerosol technique, we measured lung mucociliary clearance before and after 7 days of domiciliary humidification. Patients inhaled high flow saturated air at 37 degrees C via a patient-operated humidification nasal inhalation system for 3 h per day. We assessed tracheobronchial mucociliary clearance from the retention of (99m)Tc-labelled polystyrene tracer particles monitored for 6 h, with a follow-up 24-h reading. Ten out of 14 initially recruited patients (age 37-75 years; seven females) completed the study (two withdrew after their initial screening and two prior to the initial clearance test). Seven patients studied were non-smokers; three were ex-smokers (1-9 pack-years). Initial tracer radioaerosol distribution was closely similar between pre- and post-treatment. Following humidification, lung mucociliary clearance significantly improved, the area under the tracheobronchial retention curve decreased from 319 +/- 50 to 271 +/- 46%h (p humidification treatment improved lung mucociliary clearance in our bronchiectatic patients. Given this finding plus increasing laboratory and clinical interest in humidification mechanisms and effects, we believe further clinical trials of humidification therapy are desirable, coupled with analysis of humidification effects on mucus properties and transport.

  18. Iohexol plasma clearance measurement in older adults with chronic kidney disease-sampling time matters.

    Science.gov (United States)

    Ebert, Natalie; Loesment, Amina; Martus, Peter; Jakob, Olga; Gaedeke, Jens; Kuhlmann, Martin; Bartel, Jan; Schuchardt, Mirjam; Tölle, Markus; Huang, Tao; van der Giet, Markus; Schaeffner, Elke

    2015-08-01

    Accurate and precise measurement of GFR is important for patients with chronic kidney disease (CKD). Sampling time of exogenous filtration markers may have great impact on measured GFR (mGFR) results, but there is still uncertainty about optimal timing of plasma clearance measurement in patients with advanced CKD, for whom 24-h measurement is recommended. This satellite project of the Berlin Initiative Study evaluates whether 24-h iohexol plasma clearance reveals a clinically relevant difference compared with 5-h measurement in older adults. In 104 participants with a mean age of 79 years and diagnosed CKD, we performed standard GFR measurement over 5 h (mGFR300) using iohexol plasma concentrations at 120, 180, 240 and 300 min after injection. With an additional sample at 1440 min, we assessed 24-h GFR measurement (mGFR1440). Study design was cross-sectional. Calculation of mGFR was conducted with a one compartment model using the Brochner-Mortensen equation to calculate the fast component. mGFR values were compared with estimated GFR values (MDRD, CKD-EPI, BIS1, Revised Lund-Malmö and Cockcroft-Gault). In all 104 subjects, mGFR1440 was lower than mGFR300 (23 ± 8 versus 29 ± 9 mL/min/1.73 m(2), mean ± SD; P clearance up to 5 h leads to a clinically relevant overestimation of GFR compared with 24-h measurement. In clinical care, this effect should be bore in mind especially for patients with considerably reduced GFR levels. A new correction formula has been developed to predict mGFR1440 from mGFR300. For accurate GFR estimates in elderly CKD patients, we recommend the Revised Lund Malmö equation. © The Author 2015. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  19. Improving accuracy of ET measurement of LISS nozzle to calandria tube clearance

    International Nuclear Information System (INIS)

    Craig, S.T.; Krause, T.W.; Schankula, J.J.

    2006-01-01

    The AECL Fuel Channel Inspection System (AFCIS) has been used in an in-reactor field trial to successfully measure the clearance between Liquid Injection Shutdown System (LISS) nozzles and calandria tubes. Each measurement over the full length of a channel added only 15 minutes to the on-channel inspection time. No changes were required to the inspection heads. The only equipment changes made were the addition of a Remote Field Eddy Current (RFEC) module to the eddy current instrument, and minor wiring changes, at the instrument, to achieve a RFEC configuration. With the experience gained from the field trial, factors potentially limiting accuracy were identified. These, and other factors, were investigated and are discussed herein. The RFEC probe is delivered inside the pressure tube. Magnetic fields from the RFEC probe extend through the conducting walls of the pressure tube and calandria tube to interact with the LISS nozzle. Data acquired during the field trial showed the LISS nozzle signal is distinct and the signal-to-noise ratio is very favourable. Nevertheless, comparison of the RFEC measurements to a visual examination, made during the same outage, had the RFEC method underestimating the clearance by 2.5 mm on average. By way of laboratory tests, the following factors were investigated as potential sources of error: resistivity and geometry of LISS nozzle reference/calibration pieces, pressure-tube wall thickness, diameter and resistivity variations, pressure-tube to calandria-tube gap, and radial offsets of the probe within the pressure-tube. The sensitivity to these various noise sources was established. A model, based on fundamental electromagnetic principles, was developed and was used to normalize the effects of LISS nozzle conductivity and geometry. This enabled compensation for various sources of error, and made it possible to produce a correction factor for the field trial data, reducing the average difference from the visual inspection of LISS

  20. The effect of reticuloendothelial blockade on the blood clearance and tissue distribution of liposomes

    International Nuclear Information System (INIS)

    Souhami, R.L.; Patel, H.M.; Ryman, B.E.

    1981-01-01

    The blood clearance and tissue distribution of liposomes have been studied in mice subjected to reticuloendothelial blockade with dextran sulphate or carbon. The liposomes have been labelled in the lipid membranes with [ 3 H]-cholesterol, [ 14 C]phosphatidylcholine and/or 99 sup(m)Tc and the content with [ 14 C]inulin. Reticuloendothelial blockade has been shown to slow the rate of clearance of neutral, positively and negatively charged liposomes and of both small unilamellar vesicles and large multilamellar vesicles. In normal animals, the liver uptake accounted for only 20-55% of the total injected radioactivity, the amount varying with the charge and size of the liposomes. Following blockade, the liver uptake of charged and neutral multilamellar liposomes was depressed. This was also true for negatively charged small unilamellar vesicles. The degree of depression of hepatic uptake was between 25-50%, which contrasts with the 80-90% reduction in uptake of a wholly phagocytosed particle (sheep red cells). This difference suggets that mechanisms other than Kupffer cell phagocytosis are also responsible for the normal uptake of liposomes into the liver. In the case of neutral and positively charged small unilamellar vesicles, delayed clearance due to blockade was not associated with depressed hepatic uptake. The site of action of blockading agents for these preparations is not clear. With all preparations of liposomes, blockade produced a slight and variable increase in uptake in the lung and spleen. The alteration of distribution of liposomes by reticuloendothelial blockade is therefore not great and the value of the technique in modifying the tissue distribution of substances within liposomes may be limited. (orig.)

  1. Lymphatic albumin clearance from psoriatic skin

    International Nuclear Information System (INIS)

    Staberg, B.; Klemp, P.; Aasted, M.; Worm, A.M.; Lund, P.

    1983-01-01

    In nine patients with untreated psoriasis vulgaris, human serum albumin labelled with 125 I or 131 I was injected intradermally in symmetrically located involved and uninvolved skin. The activity of the depots was followed by external detection, and the arrival of labelled albumin in plasma was monitored. In involved psoriatic skin the local mean half-time (T1/2) for tracer disappearance was 20.8 +/- 8.2 (S.D.) hr and in clinically normal skin, 29.1 +/- 9.6 (S.D.) hr. The difference was significant (p less than 0.002). Accordingly, the tracer from involved skin reached higher plasma levels than the tracer from uninvolved skin. However, under slight lymphatic stasis the appearance rate of radiolabelled albumin in plasma from both tissues was minimal during 1 to 2 hours after the injection, indicating that a local direct transvascular drainage of plasma albumin from the interstitium of diseased and normal skin was negligible. We conclude that the previously demonstrated increased extravasation of plasma proteins in involved psoriatic skin is compensated by an increased lymphatic drainage of plasma proteins, and not by an increased local transvascular return

  2. Multicenter trial validation of a camera-based method to measure Tc-99m mercaptoacetyltriglycine, or Tc-99m MAG3, clearance.

    Science.gov (United States)

    Taylor, A; Manatunga, A; Morton, K; Reese, L; Prato, F S; Greenberg, E; Folks, R; Kemp, B J; Jones, M E; Corrigan, P E; Galt, J; Eshima, L

    1997-07-01

    To evaluate an improved camera-based method for calculating the clearance of technetium-99m mercaptoacetyltriglycine (MAG3) in a multicenter trial. Tc-99m MAG3 scintigraphy was performed in 49 patients at three sites in the United States and Canada. The percentage of the injected dose of Tc-99m MAG3 in the kidney at 1-2, 1.0-2.5, and 2-3 minutes after injection was correlated with the plasma-based Tc-99m MAG3 clearances. The data were combined with the results obtained in 20 additional patients in a previously published pilot study. Regression models correlating the plasma-based Tc-99m MAG3 clearance with the percentage uptake in the kidney for each time interval were developed; there was no statistically significant difference among sites in the regression equations. Correction for body surface area statistically significantly (P time interval. For the 1.0-2.5-minute interval, the body surface area-corrected correlation coefficient for the four combined sites was .87, and it improved to .93 when one outlier was omitted from the analysis. Similar results were obtained with the other time intervals. Independent processing by two observers showed no clinically important differences in the percentage dose in the kidney or in relative function. An improved camera-based method to calculate the clearance of Tc-99m MAG3 was validated in a multicenter trial.

  3. Omega-3 polyunsaturated fatty acids promote amyloid-β clearance from the brain through mediating the function of the glymphatic system.

    Science.gov (United States)

    Ren, Huixia; Luo, Chuanming; Feng, Yanqing; Yao, Xiaoli; Shi, Zhe; Liang, Fengyin; Kang, Jing X; Wan, Jian-Bo; Pei, Zhong; Su, Huanxing

    2017-01-01

    Impairment of amyloid-β (Aβ) clearance leads to Aβ accumulation in the brain during the development of Alzheimer's disease (AD). Strategies that can restore or improve the clearance function hold great promise in delaying or preventing the onset of AD. Here, we show that n-3 polyunsaturated fatty acids (PUFAs), by use of fat-1 transgenic mice and oral administration of fish oil, significantly promote interstitial Aβ clearance from the brain and resist Aβ injury. Such beneficial effects were abolished in Aqp4-knockout mice, suggesting that the AQP4-dependent glymphatic system is actively involved in the promoting the effects of n-3 PUFAs on the clearance of extracellular Aβ. Imaging on clarified brain tissues clearly displayed that n-3 PUFAs markedly inhibit the activation of astrocytes and protect the AQP4 polarization in the affected brain region after Aβ injection. The results of the present study prove a novel mechanism by which n-3 PUFAs exert protective roles in reducing Aβ accumulation via mediating the glymphatic system function.-Ren, H., Luo, C., Feng, Y., Yao, X., Shi, Z., Liang, F., Kang, J. X., Wan, J.-B., Pei, Z., Su, H. Omega-3 polyunsaturated fatty acids promote amyloid-β clearance from the brain through mediating the function of the glymphatic system. © FASEB.

  4. Modified Augmented Renal Clearance Score Predicts Rapid Piperacillin and Tazobactam Clearance in Critically Ill Surgery and Trauma Patients

    Science.gov (United States)

    2014-04-24

    collision; VAP , ventilator-associated pneumonia. TABLE 2. PK Parameter Estimates for Free Piperacillin and Tazobactam in Patients Stratified by ARC Score...SOFA score are typically generated during routine care of the most severely ill patients . Positive screening test results (high ARC scores) can be...Modified Augmented Renal Clearance score predicts rapid piperacillin and tazobactam clearance in critically ill surgery and trauma patients Kevin S

  5. Uptake and clearance of plutonium-238 from liver cells transplanted into fat pads of F344 rats

    International Nuclear Information System (INIS)

    Brooks, A.L.; Guilmette, R.A.; Hahn, F.F.

    1986-01-01

    Animals injected with liver cells and control animals received a single intraperitoneal injection of 37 kBq (1 μCi) 238 Pu citrate and were serially sacrificed. It was observed that the cells of the intact liver took up about twice as much 238 Pu as liver cells transplanted into the fat pads of the same animal. The retention half-life was 8.3 days for the total activity in the liver, 20 days using tracks/cell measurements in the liver and 16 days for the tracks/cell measurements in the liver cells translocated to fat pads. When the data on tracks/cell were standardized relative to the amount of Pu present at 5 days after injection, there was no significant difference between the retention of Pu in liver cells from intact animals and liver cells transplanted into the fat pads. About 20% of the 5-day Pu liver burden in both liver cells and liver cells transplanted into fat pads was retained at 70 days. The smaller retention and clearance for liver cells in different environments indicate that uptake and clearance of Pu from the body is dependent, to a major extent, upon hepatocyte function. (author)

  6. /sup 133/Xe clearance technique in the assessment of hypogastric arteries insufficiency

    Energy Technology Data Exchange (ETDEWEB)

    Vattimo, A.; Setacci, C.; Lore, F.; Pisani, M.; Campoccia, G.

    1982-10-01

    The clearance of the radioactive inert gas /sup 133/Xenon injected intramuscularly in the gluteal region was studied in healthy subjects and in patients with aortoiliac disease, in order to measure the muscular blood flow (MBF) in the vascular bed of the hypogastric arteries. At rest MBF averaged 6.0 +- 2.1 SD ml/100 g per min in healthy subjects and 5.1 +- 2.7 ml/100 g per min in patients with arterial disease. After exercise-induced hyperemia, maximal MBF in healthy subjects averaged 121.6 +- 60.9 ml/100 g per min, a value markedly higher than the corresponding 6.0 +- 3.6 ml/100 g per min observed in vascular disease patients. The /sup 133/Xe values corresponded well, in patients with occlusive vascular disease, with the results obtained in the same subjects by measurement of the penile blood pressure using a Doppler shift ultrasound detector. The /sup 133/Xe clearance is a simple and reliable procedure, which could be particularly useful for an assessment of the conditions of hypogastric arteries prior to abdominal surgery.

  7. The 133Xe clearance technique in the assessment of hypogastric arteries insufficiency

    International Nuclear Information System (INIS)

    Vattimo, A.; Setacci, C.; Lore, F.; Pisani, M.; Campoccia, G.

    1982-01-01

    The clearance of the radioactive inert gas 133 Xenon injected intramuscularly in the gluteal region was studied in healthy subjects and in patients with aortoiliac disease, in order to measure the muscular blood flow (MBF) in the vascular bed of the hypogastric arteries. At rest MBF averaged 6.0 +- 2.1 SD ml/100 g per min in healthy subjects and 5.1 +- 2.7 ml/100 g per min in patients with arterial disease. After exercise-induced hyperemia, maximal MBF in healthy subjects averaged 121.6 +- 60.9 ml/100 g per min, a value markedly higher than the corresponding 6.0 +- 3.6 ml/100 g per min observed in vascular disease patients. The 133 Xe values corresponded well, in patients with occlusive vascular disease, with the results obtained in the same subjects by measurement of the penile blood pressure using a Doppler shift ultrasound detector. The 133 Xe clearance is a simple and reliable procedure, which could be particularly useful for an assessment of the conditions of hypogastric arteries prior to abdominal surgery. (orig.) [de

  8. Distribution and clearance of PEG-single-walled carbon nanotube cancer drug delivery vehicles in mice.

    Science.gov (United States)

    Bhirde, Ashwin A; Patel, Sachin; Sousa, Alioscka A; Patel, Vyomesh; Molinolo, Alfredo A; Ji, Youngmi; Leapman, Richard D; Gutkind, J Silvio; Rusling, James F

    2010-12-01

    To study the distribution and clearance of polyethylene glycol (PEG)-ylated single-walled carbon nanotube (SWCNTs) as drug delivery vehicles for the anticancer drug cisplatin in mice. PEG layers were attached to SWCNTs and dispersed in aqueous media and characterized using dynamic light scattering, scanning transmission electron microscopy and Raman spectroscopy. Cytotoxicity was assessed in vitro using Annexin-V assay, and the distribution and clearance pathways in mice were studied by histological staining and Raman spectroscopy. Efficacy of PEG-SWCNT-cisplatin for tumor growth inhibition was studied in mice. PEG-SWCNTs were efficiently dispersed in aqueous media compared with controls, and did not induce apoptosis in vitro. Hematoxylin and eosin staining, and Raman bands for SWCNTs in tissues from several vital organs from mice injected intravenously with nanotube bioconjugates revealed that control SWCNTs were lodged in lung tissue as large aggregates compared with the PEG-SWCNTs, which showed little or no accumulation. Characteristic SWCNT Raman bands in feces revealed the presence of bilary or renal excretion routes. Attachment of cisplatin on bioconjugates was visualized with Z-contrast scanning transmission electron microscopy. PEG-SWCNT-cisplatin with the attached targeting ligand EGF successfully inhibited growth of head and neck tumor xenografts in mice. PEG-SWCNTs, as opposed to control SWCNTs, form more highly dispersed delivery vehicles that, when loaded with both cisplatin and EGF, inhibit growth of squamous cell tumors.

  9. SQL injection detection system

    OpenAIRE

    Vargonas, Vytautas

    2017-01-01

    SQL injection detection system Programmers do not always ensure security of developed systems. That is why it is important to look for solutions outside being reliant on developers. In this work SQL injection detection system is proposed. The system analyzes HTTP request parameters and detects intrusions. It is based on unsupervised machine learning. Trained by regular request data system detects outlier user parameters. Since training is not reliant on previous knowledge of SQL injections, t...

  10. Hemodynamic and permeability characteristics of acute experimental necrotizing enterocolitis

    International Nuclear Information System (INIS)

    Miller, M.J.; Adams, J.; Gu, X.A.; Zhang, X.J.; Clark, D.A.

    1990-01-01

    We examined the local hemodynamic response of intestinal loops during acute necrotizing enterocolitis (NEC) in anesthetized rabbits. NEC was induced in ileal loops by transmural injection of a solution containing casein (10 mg/ml) and calcium gluconate (50 mg/ml) acidified to pH 4.0 with propionic or acetic acid. Control loops received casein only (pH 5.0). Mucosal damage was quantified by the blood-to-lumen movement of [51Cr]EDTA, fluid shifts into the lumen, and histology. Mean arterial pressure and loop blood flow were steady over the 3-hr period, loop fluid volume decreased, and there was no evidence of necrosis or epithelial damage. In loops receiving acidified casein and calcium gluconate, there was an immediate dramatic increase in loop blood flow that returned to baseline by 50 min. In addition, loop fluid volume was dramatically increased, necrosis was noted in the form of blunting and loss of villi, and sevenfold increase in [51Cr]EDTA permeability was evident. Administration of CV 1808 (30 mg/kg/hr), a selective adenosine2 agonist, which maintained and elevated loop blood flow throughout the 3 hr protocol, failed to alter the changes in loop fluid volume or prevent necrosis. Histamine levels in loop fluid levels were significantly elevated 20-30 min after NEC induction when compared to saline controls, indicating an early activation of mucosal defenses with this luminal insult. Thus, this model of NEC is characterized by a transient, acute hyperemia, increased intestinal permeability, and histamine release. As mucosal damage was independent of ischemia and could not be prevented by vasodilatory therapy, this model supports the clinical findings that NEC is correlated with luminal factors related to feeding and independent of cardiovascular stress

  11. Cutaneous blood flow. A comparative study between the thermal recovery method and the radioxenon clearance method

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, C M; Ferreira, J M; Fernandes, F V

    1975-01-01

    Since 1968 a thermal recovery method to study the cutaneous circulation has been utilized in the detection of skin circulation changes caused by certain pharmacological agents or by some pathological conditions. This method is based in the determination of the thermal recuperation of a small area of the skin previously cooled. In this work, we want to present the results of a comparative analysis between the thermal recovery method and the clearance of the radioactive xenon injected intracutaneously. The study was performed in the distal extremity of the lower limbs in 16 normal subjects, 16 hyperthyroid patients with increased cutaneous temperature and 11 patients with presumably low cutaneous blood flow (3 patients with hypothyroidism and 8 with obstructive arteriosclerosis).

  12. Predictive value of intracutaneous xenon clearance for healing of amputation and cutaneous ulcer sites

    International Nuclear Information System (INIS)

    Silberstein, E.B.; Thomas, S.; Cline, J.; Kempczinski, R.; Gottesman, L.

    1983-01-01

    A previously reported technique for the assessment of skin blood flow in the lower extremities of patients with ischemic lesions was evaluated using intracutaneous xenon clearance. The radioisotope was injected above and below both the ankle and the knee and flow was measured using a gamma camera with a low-energy collimator, 88-keV photopeak, and a 20% window. Healing was more frequent when skin blood flow was equal to or greater than 2.4 ml/min/100 g (38/39 patients) than when flow was less than 2.4 ml/min/100 g (4/7 patients). The authors conclude that this technique can be used to help determine the appropriate site for amputation in lower limb ischemic lesions

  13. Piezoelectric Injection Systems

    Science.gov (United States)

    Mock, R.; Lubitz, K.

    The origin of direct injection can be doubtlessly attributed to Rudolf Diesel who used air assisted injection for fuel atomisation in his first self-ignition engine. Although it became apparent already at that time that direct injection leads to reduced specific fuel consumption compared to other methods of fuel injection, it was not used in passenger cars for the moment because of its disadvantageous noise generation as the requirements with regard to comfort were seen as more important than a reduced specific consumption.

  14. Urinary incontinence - injectable implant

    Science.gov (United States)

    ... repair; ISD repair; Injectable bulking agents for stress urinary incontinence ... and disorders: physiology of micturition, voiding dysfunction, urinary incontinence, urinary tract infections, and painful bladder syndrome. In: Lobo ...

  15. Approaches towards establishing of clearance levels in Japan

    International Nuclear Information System (INIS)

    Sumitani, N.; Watanabe, I.; Okoshi, M.

    1998-01-01

    It is important to establish necessary regulatory systems for decommissioning waste management, especially to establish clearance levels from regulatory control. To establish the regulatory systems, the Nuclear Safety Commission (NSC) has been discussing the unconditional clearance levels for materials from nuclear reactors since May 1997. The NSC tries to derive unconditional clearance levels for the materials such as concrete and ferrous metal, arising from nuclear reactor decommissioning. In the derivation, both disposal and recycle/reuse of the materials are considered. Typical scenarios and parameter values for dose estimation are selected considering the Japanese natural and social conditions. Preliminary clearance levels were derived from 10 μSv/yr of individual dose criterion and deterministic analysis. For most radionuclides, the preliminary results are the same order of magnitude recommended in IAEA-TECDOC-855. Some radionuclides such as β emitters, however, are different order of magnitude from those recommended in IAEA-TECDOC-855. It is necessary that international organizations lead the discussions on the clearance levels to conclude final consensus. (author)

  16. Predicting Human Clearance of OATP substrates using Cynomolgus monkey: In vitro-in vivo scaling of hepatic uptake clearance.

    Science.gov (United States)

    de Bruyn, Tom; Ufuk, Ayse; Cantrill, Carina; Kosa, Rachel E; Bi, Yi-An; Niosi, Mark; Modi, Sweta; Rodrigues, A David; Tremaine, Larry M; Varma, Manthena Vs; Galetin, Aleksandra; Houston, J Brian

    2018-05-02

    This work explores the utility of the cynomolgus monkey as a preclinical model to predict hepatic uptake clearance mediated by organic anion transporting polypeptide (OATP) transporters. Nine OATP substrates (rosuvastatin, pravastatin, repaglinide, fexofenadine, cerivastatin, telmisartan, pitavastatin, bosentan and valsartan) were investigated in plated cynomolgus monkey and human hepatocytes. Total uptake clearance and passive diffusion were measured in vitro from initial rates in the absence and presence of the OATP inhibitor rifamycin SV, respectively. Total uptake clearance values in plated hepatocytes ranged over three orders of magnitude in both species with a similar rank order and good agreement in the relative contribution of active transport to total uptake between cynomolgus monkey and human. In vivo hepatic clearance for these nine drugs was determined in cynomolgus monkey after intravenous dosing. Hepatic clearances showed a similar range to human parameters and good predictions from respective hepatocyte parameters (with 2.7 and 3.8-fold bias on average, respectively). The use of cross species empirical scaling factors (based on either dataset average or individual drug scaling factor from cynomolgus monkey data) improved prediction (less bias, better concordance) of human hepatic clearance from human hepatocyte data alone. In vitro intracellular binding in hepatocytes also correlated well between species. It is concluded that the minimal species differences observed for the current dataset between cynomolgus monkey and human hepatocyte uptake, both in vitro and in vivo, support future use of this preclinical model to delineate drug hepatic uptake and enable prediction of human in vivo intrinsic hepatic clearance. The American Society for Pharmacology and Experimental Therapeutics.

  17. Electron injection in microtron

    International Nuclear Information System (INIS)

    Axinescu, S.

    1977-01-01

    A review of the methods of injecting electrons in the microtron is presented. A special attention is paid to efficient injection systems developed by Wernholm and Kapitza. A comparison of advantages and disadvantages of both systems is made in relation to the purpose of the microtron. (author)

  18. Glenohumeral Joint Injections

    Science.gov (United States)

    Gross, Christopher; Dhawan, Aman; Harwood, Daniel; Gochanour, Eric; Romeo, Anthony

    2013-01-01

    Context: Intra-articular injections into the glenohumeral joint are commonly performed by musculoskeletal providers, including orthopaedic surgeons, family medicine physicians, rheumatologists, and physician assistants. Despite their frequent use, there is little guidance for injectable treatments to the glenohumeral joint for conditions such as osteoarthritis, adhesive capsulitis, and rheumatoid arthritis. Evidence Acquisition: We performed a comprehensive review of the available literature on glenohumeral injections to help clarify the current evidence-based practice and identify deficits in our understanding. We searched MEDLINE (1948 to December 2011 [week 1]) and EMBASE (1980 to 2011 [week 49]) using various permutations of intra-articular injections AND (corticosteroid OR hyaluronic acid) and (adhesive capsulitis OR arthritis). Results: We identified 1 and 7 studies that investigated intra-articular corticosteroid injections for the treatment of osteoarthritis and adhesive capsulitis, respectively. Two and 3 studies investigated the use of hyaluronic acid in osteoarthritis and adhesive capsulitis, respectively. One study compared corticosteroids and hyaluronic acid injections in the treatment of osteoarthritis, and another discussed adhesive capsulitis. Conclusion: Based on existing studies and their level of evidence, there is only expert opinion to guide corticosteroid injection for osteoarthritis as well as hyaluronic acid injection for osteoarthritis and adhesive capsulitis. PMID:24427384

  19. Dimethyl Ether Injection Studies

    DEFF Research Database (Denmark)

    Sorenson, Spencer C.; Glensvig, Michael; Abata, Duane L.

    1998-01-01

    A series of preliminary investigations has been performed in order to investigate the behavior of DME in a diesel injection environment. These studies have in-cluded visual observations of the spray penetration and angles for high pressure injection into Nitrogen using conventional jerk pump inje...

  20. Clearance of iron oxide particles in rat liver: effect of hydrated particle size and coating material on liver metabolism.

    Science.gov (United States)

    Briley-Saebo, Karen C; Johansson, Lars O; Hustvedt, Svein Olaf; Haldorsen, Anita G; Bjørnerud, Atle; Fayad, Zahi A; Ahlstrom, Haakan K

    2006-07-01

    We sought to evaluate the effect of the particle size and coating material of various iron oxide preparations on the rate of rat liver clearance. The following iron oxide formulations were used in this study: dextran-coated ferumoxide (size = 97 nm) and ferumoxtran-10 (size = 21 nm), carboxydextran-coated SHU555A (size = 69 nm) and fractionated SHU555A (size = 12 nm), and oxidized-starch coated materials either unformulated NC100150 (size = 15 nm) or formulated NC100150 injection (size = 12 nm). All formulations were administered to 165 rats at 2 dose levels. Quantitative liver R2* values were obtained during a 63-day time period. The concentration of iron oxide particles in the liver was determined by relaxometry, and these values were used to calculate the particle half-lives in the liver. After the administration of a high dose of iron oxide, the half-life of iron oxide particles in rat liver was 8 days for dextran-coated materials, 10 days for carboxydextran materials, 14 days for unformulated oxidized-starch, and 29 days for formulated oxidized-starch. The results of the study indicate that materials with similar coating but different sizes exhibited similar rates of liver clearance. It was, therefore, concluded that the coating material significantly influences the rate of iron oxide clearance in rat liver.

  1. Analysis of blood clearance and labeled metabolites for the estrogen receptor tracer [F-18]-16α-fluorestradiol (FES)

    International Nuclear Information System (INIS)

    Mankoff, David A.; Tewson, Timothy J.; Eary, Janet F.

    1997-01-01

    [F-18] 16α-Fluoroestradiol (FES) has been shown to be a tracer of estrogen receptor content in breast tumors; however, quantitative analysis of FES images is complicated by the rapid metabolism of the tracer in vivo. To optimize FES PET imaging studies and to provide an input function for the quantitative analysis of the tracer FES uptake in breast tumors, we studied the clearance and metabolism of FES in 15 breast cancer patients. FES clearance, protein binding, and metabolite production and limited assays to determine the identity of labeled metabolites were performed. These studies show that FES was rapidly cleared from the blood and metabolized; at 20 min only 20% of the circulating radioactivity was unmetabolized FES, and much of this was protein bound. The detectable metabolites in either blood or urine are conjugation products, largely the glucuronide and the sulfate of FES, and these are excreted through the kidneys at a rate comparable to their introduction into the circulation. After 20 min postinjection the blood levels of radioactivity remain fairly constant. Our results, the first report on human metabolites, are in close agreement with previous animal studies of FES metabolism. These studies show that because FES clearance is rapid and metabolite background is nearly constant, imaging starting at 20 to 30 min after injection may provide good visualization of estrogen-containing tissues. Labeled metabolites need to be accounted for in quantifying FES uptake

  2. Scan Manifestations and Blood Clearance Rates in Typhoid Liver

    International Nuclear Information System (INIS)

    Bahk, Yong Whee; Ahn, Jae Sung; Kim, Soon Hi

    1970-01-01

    Fourteen patients with typhoid fever studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold ( 198 Au). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 percent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 percent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increase in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or less a normal) clearance time are characteristic of typhoid fever.

  3. Scan Manifestations and Blood Clearance Rates in Typhoid Liver

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong Whee; Ahn, Jae Sung; Kim, Soon Hi [St. Mary' s Hospital, Catholic Medical College, Seoul (Korea, Republic of)

    1970-09-15

    Fourteen patients with typhoid fever studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold ({sup 198}Au). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 percent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 percent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increase in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or less a normal) clearance time are characteristic of typhoid fever.

  4. HPT Clearance Control: Intelligent Engine Systems-Phase 1

    Science.gov (United States)

    2005-01-01

    The following work has been completed to satisfy the Phase I Deliverables for the "HPT Clearance Control" project under NASA GRC's "Intelligent Engine Systems" program: (1) Need for the development of an advanced HPT ACC system has been very clearly laid out, (2) Several existing and potential clearance control systems have been reviewed, (3) A scorecard has been developed to document the system, performance (fuel burn, range, payload, etc.), thermal, and mechanical characteristics of the existing clearance control systems, (4) Engine size and flight cycle selection for the advanced HPT ACC system has been reviewed with "large engine"/"long range mission" combination showing the most benefit, (5) A scoring criteria has been developed to tie together performance parameters for an objective, data driven comparison of competing systems, and (6) The existing HPT ACC systems have been scored based on this scoring system.

  5. Clearance potential of ITER vacuum vessel activated materials

    International Nuclear Information System (INIS)

    Cepraga, D.G.; Cambi, G.; Frisoni, M.

    2002-01-01

    To demonstrate fusion's environmental attractiveness over the entire life cycle, a waste analysis is mandatory. The clearance is recommended by IAEA for releasing activated solid materials from regulatory control and for waste management policy. The paper focuses on the approach used to support waste analyses for ITER Generic Site Safety Report. The Material Unconditional Clearance Index of all the materials/zones on the equatorial mid-plane of ITER machine have been evaluated, based on IAEA-TECDOC-855. The Bonami-Nitawl-XSDNRPM sequence of the Scale-4.4a code system (using Vitenea-J library) has been firstly used for radiation transport analyses. Then the Anita-2000 code package is used for the activation calculation. The paper presents also, as an example, an application of the clearance indexes estimation for the ITER vacuum vessel materials. The results of the Anita-2000 have been compared with those obtained using the Fispact-99 activation code. (author)

  6. APPLICATION OF DSM IN OBSTACLE CLEARANCE SURVEYING OF AERODROME

    Directory of Open Access Journals (Sweden)

    X. Qiao

    2016-06-01

    Full Text Available Compared to the wide use of digital elevation model (DEM, digital surface model (DSM receives less attention because that it is composed by not only terrain surface, but also vegetations and man-made objects which are usually regarded as useless information. Nevertheless, these objects are useful for the identification of obstacles around an aerodrome. The primary objective of the study was to determine the applicability of DSM in obstacle clearance surveying of aerodrome. According to the requirements of obstacle clearance surveying at QT airport, aerial and satellite imagery were used to generate DSM, by means of photogrammetry, which was spatially analyzed with the hypothetical 3D obstacle limitation surfaces (OLS to identify the potential obstacles. Field surveying was then carried out to retrieve the accurate horizontal position and height of the obstacles. The results proved that the application of DSM could make considerable improvement in the efficiency of obstacle clearance surveying of aerodrome.

  7. Regulation Concepts for Clearance Level of Radionuclide in Solid Materials

    International Nuclear Information System (INIS)

    Nanang Triagung Edi Hermawan

    2008-01-01

    Practices of nuclear energy have expanded in some fields such as researches and development, educations, agricultures, medicines and industries. Every practice beside give much benefit, could generate residue or waste. Radioactive waste needs management to ensure the safety of workers, member of the public, and for the eternal of environment. The product of radioactive waste management, in generally, is some containment of radionuclide concentration in solid matrix material after immobilization or conditioning process. Some kind of processed radioactive wastes with short half live then decay faster to stabile condition. The decay will reach clearance level in sometimes, so from the radiation protection views is harmless. This materials above didn’t need control and must be cleared from all determinate and regulation aspects of radioactive material practices. There is clearance for harmless material off course will be simplify management task and efficiency of money. So the regulation about clearance levels will be important as law basic for technical practices in field. (author)

  8. Exaggerated natriuresis and lithium clearance in spontaneously hypertensive rats

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Kanters, J K; Leyssac, P P

    1988-01-01

    Since hypertension is associated with changes in the handling of various cations (including sodium and lithium) across the cell membrane, the present study investigated the validity of the lithium clearance method in hypertension by comparing two measures of proximal reabsorption. Thus, fractional...... lithium excretion and transit time (TT)-occlusion time (OT; e-TT/T) were determined successively in the same spontaneously hypertensive rat (SHR, Okamoto strain). The rats were examined both before and after an acute saline load. The results show that the lithium clearance method can be used...... for the determination of proximal reabsorption in SHR. Utilizing the lithium clearance method, the changes in renal sodium handling underlying the exaggerated natriuresis were investigated in unanaesthetized catheterized rats. It was found that the exaggerated natriuresis was associated with an increased output from...

  9. Kinematics Simulation Analysis of Packaging Robot with Joint Clearance

    Science.gov (United States)

    Zhang, Y. W.; Meng, W. J.; Wang, L. Q.; Cui, G. H.

    2018-03-01

    Considering the influence of joint clearance on the motion error, repeated positioning accuracy and overall position of the machine, this paper presents simulation analysis of a packaging robot — 2 degrees of freedom(DOF) planar parallel robot based on the characteristics of high precision and fast speed of packaging equipment. The motion constraint equation of the mechanism is established, and the analysis and simulation of the motion error are carried out in the case of turning the revolute clearance. The simulation results show that the size of the joint clearance will affect the movement accuracy and packaging efficiency of the packaging robot. The analysis provides a reference point of view for the packaging equipment design and selection criteria and has a great significance on the packaging industry automation.

  10. Metabolism of injected barium in six healthy men

    International Nuclear Information System (INIS)

    Newton, D.; Harrison, G.E.; Kang, C.; Warner, A.J.

    1991-01-01

    Data are presented on the early metabolism and long-term retention of 133Ba (half-life 10.74 y) injected into six healthy male volunteers at ages 25-81 y. The tracer appeared to be mainly skeletal within several days, much earlier than predicted by the ICRP's model of alkaline earth metabolism. Excretion was mainly fecal, the relative fecal: urinary clearance up to 14 d ranging from 6 to 15 in the six subjects. The whole-body retention at 50 d (mean 8%, range 4.5 to 12%) was similar to that inferred from published data on the retention of injected Ra in man (mean 7%, range 3-13%). For about 1 y thereafter, the retention of Ba could be represented by simple power functions of time, with the rate of loss correlating with the excretory plasma clearance rate inferred over the first 4 d. In the subject aged 81 y, the pattern differed from that established following an earlier injection at age 60, but the differences were not necessarily related to advancing age

  11. Astragalus Injection for Hypertensive Renal Damage: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Tian Sun

    2012-01-01

    Full Text Available Objective. To evaluate the effectiveness of astragalus injection (a traditional Chinese patent medicine for patients with renal damage induced by hypertension according to the available evidence. Methods. We searched MEDLINE, China National Knowledge Infrastructure (CNKI, Chinese VIP Information, China Biology Medicine (CBM, and Chinese Medical Citation Index (CMCI, and the date of search starts from the first of database to August 2011. No language restriction was applied. We included randomized controlled trials testing astragalus injection against placebo or astragalus injection plus antihypertensive drugs against antihypertensive drugs. Study selection, data extraction, quality assessment, and data analyses were conducted according to the Cochrane review standards. Results. 5 randomized trials (involving 429 patients were included and the methodological quality was evaluated as generally low. The pooled results showed that astragalus injection was more effective in lowering β2-microglobulin (β2-MG, microalbuminuria (mAlb compared with placebo, and it was also superior to prostaglandin in lowering blood urea nitrogen (BUN, creatinine clearance rate (Ccr. There were no adverse effects reported in the trials from astragalus injection. Conclusions. Astragalus injection showed protective effects in hypertensive renal damage patients, although available studies are not adequate to draw a definite conclusion due to low quality of included trials. More rigorous clinical trials with high quality are warranted to give high level of evidence.

  12. The distribution of CIK cell after intravenous injection in animals

    International Nuclear Information System (INIS)

    Chen Shaoliang; Chen Xuefen; Gu Yucan; Chen Shuguang; Li Beilei; Liu Wenguan; Shi Hongcheng; Xu Lanwen; Qiao Weiwei; Wu Zhijiang; Gao Qirong

    2008-01-01

    Objective: The aim of this research was to investigate the in vivo distribution of cytokine induced killer (CIK) cell after intravenous injection in animals. Methods: CIK cell was labeled with 99 Tc m . Forty mice were equally divided into 8 groups. These mice were killed at 3, 15, 30 min and 1,3,6, 24, 48 h after intravenous 99 Tc m -CIK cell injection. The radioactivity of blood, heart, lung, liver, spleen, kidney, brain, bone and muscle were measured. Three New Zealand rabbits were scanned by dynamic SPECT imaging after intravenous injection of 37 MBq 99 Tc m -CIK cell. Serial images over whole body were acquired from immediately after injection to 48 h later. Results: The radiochemical purity of 99 Tc m -CIK cell was over 95% and remained stable within 6 h at room temperature. The clearance of 99 Tc m -CIK cell in blood was fast. High uptake of 99 Tc m -CIK cell was noted in lung, liver, spleen and kidney. Little uptake was found in heart, brain, bone and muscle. Dynamic SPECT imaging showed that 99 Tc m -CIK cell accumulated in lungs early after injection and cleared thereafter. Then the uptake in liver increased and remained there after 2 d. There was little uptake in heart, brain, bone and muscle. Conclusions: 99 Tc m -CIK cell clears fast in the blood after injection. Within 1 h, the tracer mainly accumulates in lungs. Then the uptake is mostly in liver and spleen. (authors)

  13. Nuclear security. DOE actions to improve the personnel clearance program

    International Nuclear Information System (INIS)

    Fultz, Keith O.; Bannerman, Carl J.; Daniel, Beverly A.

    1988-11-01

    The status of the Department of Energy's (DOE) implementation of recommendations in our two reports on DOE's personnel security clearance program was determined. The recommendations were aimed at improving the timeliness, accuracy, and efficiency of personnel security clearance decisions. Specifically, the objective was to determine and report on steps DOE is taking to implement these recommendations. In summary, it was found that DOE has either initiated action or is studying ways to address all the recommendations, but none of the recommendations have been completely implemented. The effectiveness of the DOE actions will depend, in part, on the adequacy of its internal control system for overseeing and evaluating program operations. DOE's personnel security clearance program is intended to provide reasonable assurance that personnel with access to classified information and materials are trustworthy. The Department requests that the Office of Personnel Management or the Federal Bureau of Investigation collect personal data on each person who requires such access to do his or her job. Based on these background investigations, DOE officials authorize individuals whose personal histories indicate that they are trustworthy to have access to classified information, secured facilities, and controlled materials as needed to perform their jobs. DOE has five types of these authorizations or personnel security clearances and must update information on personnel holding each type at 5-year intervals to confirm their continuing reliability. The five types are based on the types of security interests to which the person needs access, e.g., persons needing nuclear weapons-related data must have a Q clearance, and persons with a top secret clearance can have access to national security data classified as top secret

  14. Clearance of the cervical spine in clinically unevaluable trauma patients.

    Science.gov (United States)

    Halpern, Casey H; Milby, Andrew H; Guo, Wensheng; Schuster, James M; Gracias, Vicente H; Stein, Sherman C

    2010-08-15

    Meta-analytic costeffectiveness analysis. Our goal was to compare the results of different management strategies for trauma patients in whom the cervical spine was not clinically evaluable due to impaired consciousness, endotracheal intubation, or painful distracting injuries. We performed a structured literature review related to cervical spine trauma, radiographic clearance techniques (plain radiography, flexion/extension, CT, and MRI), and complications associated with semirigid collar use. Meta-analytic techniques were used to pool data from multiple sources to calculate pooled mean estimates of sensitivities and specificities of imaging techniques for cervical spinal clearance, rates of complications from various clearance strategies and from empirical use of semirigid collars. A decision analysis model was used to compare outcomes and costs among these strategies. Slightly more than 7.5% of patients who are clinically unevaluable have cervical spine injuries, and 42% of these injuries are associated with spinal instability. Sensitivity of plain radiography or fluoroscopy for spinal clearance was 57% (95% CI: 57%-60%). Sensitivities for CT and MRI alone were 83% (82%-84%) and 87% (84%-89%), respectively. Complications associated with collar use ranged from 1.3% (2 days) to 7.1% (10 days) but were usually minor and short-lived. Quadriplegia resulting from spinal instability missed by a clearance test had enormous impacts on longevity, quality of life, and costs. These impacts overshadowed the effects of prolonged collar application, even when the incidence of quadriplegia was extremely low. As currently used, neuroimaging studies for cervical spinal clearance in clinically unevaluable patients are not cost-effective compared with empirical immobilization in a semirigid collar.

  15. Clearance of slightly radioactive material from radiological control in Germany

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    1995-01-01

    Clearance from radiological control of slightly radioactive material arising from operation or decommissioning of nuclear installations has been practiced in Germany for nearly two decades. Meanwhile, for the clearance of metal generally approved and applicable recommendations for clearance levels have been issued. For other materials like building waste, case-by-case decisions are made by the state licensing authorities. Efforts to implement consistent sets of clearance levels for all kinds of material are under way. As several decommissioning projects will soon generate large amounts of materials from dismantling, a solution needs to be reached soon. The legal framework in Germany governing the use of atomic energy consists of the Atomic Energy Act and several ordinances. Rules and guidelines including the recommendations of the German Commission for Radiation Protection (SSK) exist on a lower level and are not legally binding. Several generic studies for the derivation of clearance levels for metals and building debris with alpha, beta, and gamma contamination have been performed on behalf of the Federal Ministry for Environment, Nature Conservation and Nuclear Safety, which oriented themselves on an individual dose of 10 microSv/a in agreement with IAEA recommendations. Stochastic models have been used for establishing the connection between specific activity of the material to be released and the resulting individual doses, with significant advantages over deterministic scenarios. In the future, for new SSK recommendations or an ordinance on clearance, the increase of masses from demolition of installations, higher recycling rates in the conventional sector and harmonization with international regulations and standards have to be taken into account

  16. Determining vancomycin clearance in an overweight and obese population.

    Science.gov (United States)

    Leong, Julie V B; Boro, Maureen S; Winter, Michaele

    2011-04-01

    Two methods of calculating vancomycin clearance were compared to determine the best body weight measure to use when dosing vancomycin for overweight and obese patients. Hospitalized veterans weighing more than 120% of their ideal body weight (IBW) with serum vancomycin concentrations (SVCs) drawn between January 1, 2003, and June 30, 2005, were eligible for study inclusion. Exclusion criteria included weight of more than 300% the IBW, unstable renal function, dialysis, uncertain vancomycin dosing or sampling times, and distribution-phase sampling. Data from January 1 through December 31, 2003 (phase 1) determined the best-fit weight for vancomycin clearance for the Leonard and Boro method. The bias and precision of the modified Leonard and Boro method using the best-fit weight for vancomycin clearance were then compared with those of the Rushing and Ambrose method for predicting SVCs from January 1, 2004, through June 30, 2005 (phase 2). Forty-eight patients were included in phase 1, with 67 SVCs for analysis. During phase 1, adjusted body weight (ABW), using the Leonard and Boro method, was superior in predicting vancomycin clearance and the resultant SVCs. A total of 96 patients were included in phase 2 of the study, with 160 SVCs for analysis. The modified Leonard and Boro method was significantly more precise than the Rushing and Ambrose method in predicting vancomycin clearance. Use of ABW proved to be superior compared with total body weight when estimating vancomycin clearance in overweight and obese patients. While there was no difference in bias between methods, the modified Leonard and Boro method was significantly more precise than the Rushing and Ambrose method in predicting SVCs when dosing vancomycin for obese patients.

  17. Acute exposure to acid fog. Effects on mucociliary clearance

    International Nuclear Information System (INIS)

    Laube, B.L.; Bowes, S.M. III; Links, J.M.; Thomas, K.K.; Frank, R.

    1993-01-01

    Submicrometric sulfuric acid (H2SO4) aerosol can affect mucociliary clearance without eliciting irritative symptoms or changes in pulmonary function. The effect of larger fog droplets containing H2SO4 on mucociliary clearance is unknown. We quantified mucociliary clearance from the trachea (n = 4) and small airways (n = 7) of young healthy male adults after an acute exposure to H2SO4 fog (MMAD = 10.3 microns; pH = 2.0; liquid water content = 481 +/- 65 mg/m3; osmolarity = 30 mOsm). Acid fog (AF) or saline fog (SF) (10.9 microns; 492 +/- 116 mg/m3; 30 mOsm) was administered for 40 min of unencumbered breathing (no mouth-piece) at rest and for 20 min of exercise sufficient to produce oronasal breathing. Fog exposures were followed by a methacholine (MCh) challenge (a measure of airway reactivity) or inhalation of technetium-99M radioaerosol (MMAD = 3.4 microns) on 2 study days each. Changes in symptoms and forced ventilatory function were also assessed. Clearance was quantified from computer-assisted analyses of gamma camera images of the lower respiratory tract in terms of %removal/min of the radiolabel from the trachea 25 min after inhalation and from the outer zone of the right lung after 1.9 to 3 h. Symptoms, forced ventilatory function, and MCh response were unaffected by either fog. Tracheal clearance was more rapid in four of four subjects after AF (0.83 +/- 1.58% removal/min) compared with that after SF (-0.54 +/- 0.85% removal/min). Outer zone clearance was more rapid in six of seven subjects after AF (0.22 +/- 0.15% removal/min) compared with that after SF (0.01 +/- 0.09% removal/min)

  18. Mucociliary clearance, airway inflammation and nasal symptoms in urban motorcyclists

    Directory of Open Access Journals (Sweden)

    Tereza C.S. Brant

    2014-01-01

    Full Text Available OBJECTIVES: There is evidence that outdoor workers exposed to high levels of air pollution exhibit airway inflammation and increased airway symptoms. We hypothesized that these workers would experience increased airway symptoms and decreased nasal mucociliary clearance associated with their exposure to air pollution. METHODS: In total, 25 non-smoking commercial motorcyclists, aged 18-44 years, were included in this study. These drivers work 8-12 hours per day, 5 days per week, driving on urban streets. Nasal mucociliary clearance was measured by the saccharine transit test; airway acidification was measured by assessing the pH of exhaled breath condensate; and airway symptoms were measured by the Sino-nasal Outcome Test-20 questionnaire. To assess personal air pollution exposure, the subjects used a passive-diffusion nitrogen dioxide (NO2 concentration-monitoring system during the 14 days before each assessment. The associations between NO2 and the airway outcomes were analyzed using the Mann-Whitney test and the Chi-Square test. Clinicaltrials.gov: NCT01976039. RESULTS: Compared with clearance in healthy adult males, mucociliary clearance was decreased in 32% of the motorcyclists. Additionally, 64% of the motorcyclists had airway acidification and 92% experienced airway symptoms. The median personal NO2 exposure level was 75 mg/m3 for these subjects and a significant association was observed between NO2 and impaired mucociliary clearance (p = 0.036. CONCLUSION: Non-smoking commercial motorcyclists exhibit increased airway symptoms and airway acidification as well as decreased nasal mucociliary clearance, all of which are significantly associated with the amount of exposure to air pollution.

  19. Further training in the fields of radiological characterisation and clearance

    International Nuclear Information System (INIS)

    Bothe, M.; Feinhals, J.; Neukaeter, E.

    2016-01-01

    Radiological characterisation and clearance require specific knowledge and skills. Targeted further training of the staff is one possibility to get this knowledge and skills. A modular concept was established, which allows adaption to specific requests of the institution and state of knowledge and skills of participants. The modules have following focuses: ''radiological characterisation and clearance'', ''sampling'' and ''measurement and sampling plans'' and consist half-and-half of lectures and group works. In group works participants apply new knowledge to examples of the installation or simulated scenarios and afterwards they present and discuss the results. This concept was carried out for different institutions and is planned for some more.

  20. Derivation methods for clearance levels applied to reactors

    International Nuclear Information System (INIS)

    Okoshi, Minoru; Seki, Takeo

    2001-01-01

    In order to support the discussion by the Nuclear Safety Commission, JAERI derived the unconditional clearance levels for concrete and metal arising from the operation and dismantling of nuclear reactors. The clearance levels of 20 radionuclides were derived from 10 μSv/y of individual doses by deterministic approach. In this approach, calculation models were established to assess individual doses resulting from 73 exposure pathways related to disposal and recycle/reuse, and realistic parameter values were selected considering Japanese natural and social conditions. The appropriateness of selected parameter values was confirmed by stochastic analyses. (author)

  1. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....

  2. TAM receptors in apoptotic cell clearance, autoimmunity, and cancer.

    Science.gov (United States)

    Nguyen, Khanh-Quynh; Tsou, Wen-I; Kotenko, Sergei; Birge, Raymond B

    2013-08-01

    Receptor tyrosine kinases, Tyro-3, Axl and Mer, collectively designated as TAM, are involved in the clearance of apoptotic cells. TAM ligands, Gas6 and Protein S, bind to the surfaces of apoptotic cells, and at the same time, interact directly with TAM expressed on phagocytes, impacting the engulfment and clearance of apoptotic cells and debris. The well-tuned and balanced actions of TAM may affect a variety of human pathologies including autoimmunity, retinal degeneration, and cancer. This article emphasizes some of the emerging findings and mechanistic insights into TAM functions that are clinically relevant and possibly therapeutically targeted.

  3. Radioactive clearance discharge of effluent from nuclear and radiation facilities

    International Nuclear Information System (INIS)

    Liu Xinhua; Xu Chunyan

    2013-01-01

    On the basis of the basic concepts of radiation safety management system exemption, exclusion and clearance, we expound that the general industrial gaseous and liquid effluent discharges are exempted or excluded, gaseous and liquid effluent discharged from nuclear and radiation facilities are clearance, and non-radioactive. The main purpose of this paper is to clarify the concepts, reach a consensus that the gaseous and liquid effluent discharged from nuclear and radiation facilities are non-radioactive and have no hazard to human health and natural environment. (authors)

  4. Dependence of 'CT clearance' on dosage and time

    International Nuclear Information System (INIS)

    Kaltenborn, H.A.; Klose, K.J.; Dexheimer, C.; Steinijans, V.

    1989-01-01

    The contrast medium dose used in CT renal function analysis corresponds to about 1 ml/kg body weight at a measurement interval of 5 or 10 minutes. In the present study the dependence of 'CT clearance' on dosage and time was examined in 12 healthy subjects. The amount of clearance was directly proportional to the employed contrast medium dose and to the length of the measurement interval. On account of the superior signal-to-noise ratio, the higher dose (1 ml/kg body weight) will continue to be prefered in future. The measurement interval can be limited to 10 minutes. (orig.) [de

  5. THE RHIC INJECTION SYSTEM.

    Energy Technology Data Exchange (ETDEWEB)

    FISCHER,W.; GLENN,J.W.; MACKAY,W.W.; PTITSIN,V.; ROBINSON,T.G.; TSOUPAS,N.

    1999-03-29

    The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.

  6. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    2014-01-01

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...

  7. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...

  8. Hip joint injection

    Science.gov (United States)

    ... medicine into the joint. The provider uses a real-time x-ray (fluoroscopy) to see where to place ... Wakefield RJ. Arthrocentesis and injection of joints and soft tissue. In: Firestein GS, Budd RC, Gabriel SE, ...

  9. Premixed direct injection disk

    Science.gov (United States)

    York, William David; Ziminsky, Willy Steve; Johnson, Thomas Edward; Lacy, Benjamin; Zuo, Baifang; Uhm, Jong Ho

    2013-04-23

    A fuel/air mixing disk for use in a fuel/air mixing combustor assembly is provided. The disk includes a first face, a second face, and at least one fuel plenum disposed therebetween. A plurality of fuel/air mixing tubes extend through the pre-mixing disk, each mixing tube including an outer tube wall extending axially along a tube axis and in fluid communication with the at least one fuel plenum. At least a portion of the plurality of fuel/air mixing tubes further includes at least one fuel injection hole have a fuel injection hole diameter extending through said outer tube wall, the fuel injection hole having an injection angle relative to the tube axis. The invention provides good fuel air mixing with low combustion generated NOx and low flow pressure loss translating to a high gas turbine efficiency, that is durable, and resistant to flame holding and flash back.

  10. Imipenem and Cilastatin Injection

    Science.gov (United States)

    Imipenem and cilastatin injection is used to treat certain serious infections that are caused by bacteria, including ... area), gynecological, blood, skin, bone, and joint infections. Imipenem is in a class of medications called carbapenem ...

  11. Quinupristin and Dalfopristin Injection

    Science.gov (United States)

    ... are in a class of medications called streptogramin antibiotics. They work by killing bacteria that cause infections.Antibiotics such as quinupristin and dalfopristin injection will not work for colds, flu, or other viral infections. Taking ...

  12. Botulinum toxin injection - larynx

    Science.gov (United States)

    Injection laryngoplasty; Botox - larynx: spasmodic dysphonia-BTX; Essential voice tremor (EVT)-btx; Glottic insufficiency; Percutaneous electromyography - guided botulinum toxin treatment; Percutaneous indirect laryngoscopy - guided botulinum toxin treatment; ...

  13. The PEP injection system

    International Nuclear Information System (INIS)

    Brown, K.L.; Avery, R.T.; Peterson, J.M.

    1988-01-01

    A system to transport 10-to-15-GeV electron and positron beams from the Stanford Linear Accelerator and to inject them into the PEP storage ring under a wide variety of lattice configurations has been designed. Optically, the transport line consists of three 360/degree/ phase-shift sections of FODO lattice, with bending magnets interspersed in such a way as to provide achromaticity, convenience in energy and emittance definition, and independent tuning of the various optical parameters for matching into the ring. The last 360/degree/ of phase shift has 88 milliradians of bend in a vertical plane and deposits the beam at the injection septum via a Lambertson magnet. Injection is accomplished by launching the beam with several centimeters of radial betatron amplitude in a fast bump provided by a triad of pulsed kicker magnets. Radiation damping reduces the collective amplitude quickly enough to allow injection at a high repetition rate

  14. Injection and Dump Systems

    CERN Document Server

    Bracco, C; Barnes, M J; Carlier, E; Drosdal, L N; Goddard, B; Kain, V; Meddahi, M; Mertens, V; Uythoven, J

    2012-01-01

    Performance and failures of the LHC injection and ex- traction systems are presented. In particular, a comparison with the 2010 run, lessons learnt during operation with high intensity beams and foreseen upgrades are described. UFOs, vacuum and impedance problems related to the injection and extraction equipment are analysed together with possible improvements and solutions. New implemented features, diagnostics, critical issues of XPOC and IQC applications are addressed.

  15. A Simple Method to Measure Renal Function in Swine by the Plasma Clearance of Iohexol

    Science.gov (United States)

    Luis-Lima, Sergio; García-Contreras, Consolación; Carrara, Fabiola; Negrín-Mena, Natalia; Jiménez-Sosa, Alejandro; Jiménez-Hernández, Hugo; Porrini, Esteban

    2018-01-01

    There is no simple method to measure glomerular filtration rate (GFR) in swine, an established model for studying renal disease. We developed a protocol to measure GFR in conscious swine by using the plasma clearance of iohexol. We used two groups, test and validation, with eight animals each. Ten milliliters of iohexol (6.47 g) was injected into the marginal auricular vein and blood samples (3 mL) were collected from the orbital sinus at different points after injection. GFR was determined using two models: two-compartment (CL2: all samples) and one-compartment (CL1: the last six samples). In the test group, CL1 overestimated CL2 by ~30%: CL2 = 245 ± 93 and CL1 = 308 ± 123 mL/min. This error was corrected by a first-order polynomial quadratic equation to CL1, which was considered the simplified method: SM = −47.909 + (1.176xCL1) − (0.00063968xCL12). The SM showed narrow limits of agreement with CL2, a concordance correlation of 0.97, and a total deviation index of 14.73%. Similar results were obtained for the validation group. This protocol is reliable, reproducible, can be performed in conscious animals, uses a single dose of the marker, and requires a reduced number of samples, and avoids urine collection. Finally, it presents a significant improvement in animal welfare conditions and handling necessities in experimental trials. PMID:29329247

  16. A Simple Method to Measure Renal Function in Swine by the Plasma Clearance of Iohexol

    Directory of Open Access Journals (Sweden)

    Sergio Luis-Lima

    2018-01-01

    Full Text Available There is no simple method to measure glomerular filtration rate (GFR in swine, an established model for studying renal disease. We developed a protocol to measure GFR in conscious swine by using the plasma clearance of iohexol. We used two groups, test and validation, with eight animals each. Ten milliliters of iohexol (6.47 g was injected into the marginal auricular vein and blood samples (3 mL were collected from the orbital sinus at different points after injection. GFR was determined using two models: two-compartment (CL2: all samples and one-compartment (CL1: the last six samples. In the test group, CL1 overestimated CL2 by ~30%: CL2 = 245 ± 93 and CL1 = 308 ± 123 mL/min. This error was corrected by a first-order polynomial quadratic equation to CL1, which was considered the simplified method: SM = −47.909 + (1.176xCL1 − (0.00063968xCL12. The SM showed narrow limits of agreement with CL2, a concordance correlation of 0.97, and a total deviation index of 14.73%. Similar results were obtained for the validation group. This protocol is reliable, reproducible, can be performed in conscious animals, uses a single dose of the marker, and requires a reduced number of samples, and avoids urine collection. Finally, it presents a significant improvement in animal welfare conditions and handling necessities in experimental trials.

  17. Decision Assessment of Clearance Level on Radioactive Waste Management

    International Nuclear Information System (INIS)

    Zainus Salimin; Gunandjar

    2007-01-01

    Radioactive waste on the safe level activity containing very small radioactive material gives small radiology influence to the human, it is not necessary to control by regulatory body. The radioactive waste on the safe level activity is safe to release as the common waste. For exemption of the control, it is required the safe activity level limits in which the value of clearance level is fulfilled by regulatory body, however until now it is not decided yet. The exemption decision is obtained if its activity is lower than or same with clearance level based on the annual effective dose receiving by public on the value is lower than or same with 0,01 mSv. The exposure pathways of radioactive waste to the human have important role for determination of clearance level. The decision assessment of clearance level on the radioactive waste management has been done by analysis of radioactive exposure pathways to the human for activities of the disposal and the recycle of solid wastes, also the release of liquid and gas effluent. For solid waste disposal, the exposure pathway was evaluated since the transportation of packed waste from the treatment facility to the disposal facility and during its operation. Exposure pathways for solid waste recycle consist of the pathways for handling and transportation of cleared material to the recycling facility, the fabrication and the utilization of its product. Exposure pathways for liquid and gas releases occur since its releases to the environment up to the human (public) by specific traffic lane. (author)

  18. Spontaneous Clearance of Hepatitis C after Liver and Renal Transplantation

    Directory of Open Access Journals (Sweden)

    CH Dale

    2009-01-01

    Full Text Available Spontaneous clearance of hepatitis C virus (HCV is rare in immunocompromised patients, such as those who have undergone organ transplantation. It has been recognized that patients receiving liver transplantation for HCV-related disease have decreased graft and patient survival compared with those transplanted for other etiologies. There is a growing trend toward treating HCV recurrence aggressively after liver transplantation. For other organ transplant recipients with concurrent HCV, treatment is not often an option, given the high rates of graft rejection and loss secondary to interferon and its immunomodulatory effects. Although spontaneous clearance of HCV has been reported in recipients of solitary liver and renal transplants, a common factor arising in these cases has been previous exposure to interferon. To date, no reports of spontaneous clearance of HCV RNA have been reported in a multiorgan transplant recipient. A case of spontaneous clearance of HCV RNA in an immunocompromised patient, within five months of simultaneous liver and kidney retransplantation is described. Importantly, this patient had no previous exposure to interferon.

  19. Hyperinsulinism and polycystic ovary syndrome (PCOS): role of insulin clearance.

    Science.gov (United States)

    Amato, M C; Vesco, R; Vigneri, E; Ciresi, A; Giordano, C

    2015-12-01

    Insulin resistance and compensatory hyperinsulinism are the predominant metabolic defects in polycystic ovary syndrome (PCOS). However, hyperinsulinism, as well as being compensatory, can also express a condition of reduced insulin clearance. Our aim was to evaluate the differences in insulin action and metabolism between women with PCOS (with normal glucose tolerance) and age- and BMI-matched women with prediabetes (without hyperandrogenism and ovulatory disorders). 22 women with PCOS and 21 age/BMI-matched women with prediabetes were subjected to a Hyperinsulinemic-euglycemic clamp and an Oral Glucose tolerance Test (OGTT). Insulin sensitivity was assessed by the glucose infusion rate during clamp (M value); insulin secretion by Insulinogenic index, Oral Disposition Index (DIo) and AUC(2h-insulin) during OGTT; and insulin clearance by the metabolic clearance rate of insulin (MCRI) during clamp. Women with PCOS showed significantly higher levels of AUC(2h-insulin) (p PCOS [420 (IQR 227-588) vs. 743 (IQR 597-888) ml m(-2) min(-1): p PCOS group, a strong independent inverse correlation was only observed between MCRI and AUC(2h-insulin) (PCOS: β:-0.878; p PCOS there is peripheral insulin sensitivity similar to that of women with prediabetes. What sets PCOS apart is the hyperinsulinism, today still simplistically defined "compensatory"; actually this is mainly related to decreased insulin clearance whose specific causes and dynamics have yet to be clarified.

  20. Royalty Fees Part I: The Copyright Clearance Center and Publishers.

    Science.gov (United States)

    Eiblum, Paula; Ardito, Stephanie C.

    1998-01-01

    Discussion of copyrights, royalty fees, and intellectual property focuses on the Copyright Clearance Center and publishers. Topics include results of a survey of library and information science journal publishers; how users verify royalty fees; how publishers determine fees; royalty fee reporting; and terms and conditions imposed on electronic…

  1. 50 CFR 14.52 - Clearance of imported wildlife.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 1 2010-10-01 2010-10-01 false Clearance of imported wildlife. 14.52 Section 14.52 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND...

  2. Online feedback-controlled renal constant infusion clearances in rats.

    Science.gov (United States)

    Schock-Kusch, Daniel; Shulhevich, Yury; Xie, Qing; Hesser, Juergen; Stsepankou, Dzmitry; Neudecker, Sabine; Friedemann, Jochen; Koenig, Stefan; Heinrich, Ralf; Hoecklin, Friederike; Pill, Johannes; Gretz, Norbert

    2012-08-01

    Constant infusion clearance techniques using exogenous renal markers are considered the gold standard for assessing the glomerular filtration rate. Here we describe a constant infusion clearance method in rats allowing the real-time monitoring of steady-state conditions using an automated closed-loop approach based on the transcutaneous measurement of the renal marker FITC-sinistrin. In order to optimize parameters to reach steady-state conditions as fast as possible, a Matlab-based simulation tool was established. Based on this, a real-time feedback-regulated approach for constant infusion clearance monitoring was developed. This was validated by determining hourly FITC-sinistrin plasma concentrations and the glomerular filtration rate in healthy and unilaterally nephrectomized rats. The transcutaneously assessed FITC-sinistrin fluorescence signal was found to reflect the plasma concentration. Our method allows the precise determination of the onset of steady-state marker concentration. Moreover, the steady state can be monitored and controlled in real time for several hours. This procedure is simple to perform since no urine samples and only one blood sample are required. Thus, we developed a real-time feedback-based system for optimal regulation and monitoring of a constant infusion clearance technique.

  3. Measuring Clearance Mechanics Based on Dynamic Leg Length

    Science.gov (United States)

    Khamis, Sam; Danino, Barry; Hayek, Shlomo; Carmeli, Eli

    2018-01-01

    The aim of this study was to quantify clearance mechanics during gait. Seventeen children diagnosed with hemiplegic cerebral palsy underwent a three-dimensional gait analysis evaluation. Dynamic leg lengths were measured from the hip joint center to the heel, to the ankle joint center and to the forefoot throughout the gait cycle. Significant…

  4. Dynamic analysis of cross shaft type universal joint with clearance

    International Nuclear Information System (INIS)

    Lu, Jian Wei; Wang, Gong Cheng; Chen, Hao; Vakakis, Alexander F.; Bergman, Lawrence A.

    2013-01-01

    Cross shaft type universal joint is widely used in ground vehicles to transfer torque between two intersecting axes, and its transmission feature can make a great contribution to NVH performance of the vehicle. We looked at the assembling clearance at cross shaft neck, and presented a dynamic model of cross shaft type universal joint with clearance at cross shaft neck. Two-state model is applied to describe the contact force between the cross shaft and driving joint fork based on Hertz theorem, and lumped mass method is applied to build up the dynamic model of the universal joint. Based on this model, numerical analysis is carried out to discuss the transmission feature of the universal joint with clearance at cross shaft neck, and the influence of clearance on the dynamic behavior of the system is evaluated with numerical results based on time history, power spectrum, and phase portrait. The method and conclusions presented are helpful to improvement of the transmission feature of cross shaft type universal joint.

  5. 75 FR 52798 - State-07, Cryptographic Clearance Records

    Science.gov (United States)

    2010-08-27

    ... Information Programs and Services, A/GIS/ IPS, Department of State, SA-2, 515 22nd Street, NW., Washington, DC... Department of State and Agency for International Development who have applied for cryptographic clearances as... that apply to all of its Privacy Act systems of records. These notices appear in the form of a...

  6. [Airway clearance techniques in chronic obstructive pulmonary syndrome : 2011 update].

    Science.gov (United States)

    Opdekamp, C

    2011-09-01

    For many years the airway clearance techniques used in chest physical therapy were assimilated with the singular technique of postural drainage, percussions and vibrations. However the side effects and counter indications and the lack of scientific proof regarding this technique have forced reflection and development of other techniques more comfortable and without deleterious effects. If all these techniques show a high efficiency in terms of improved mucociliary clearance, the literature is unanimous on how little effect these techniques have in the short and the long-term with regards to lung function and arterial blood gases. In view of the scientific literature, it is clear that the airway clearance techniques don't have the same recognition concerning their efficiency in all obstructive pulmonary diseases. As the cornerstone in the management of cystic fibrosis, the efficiency of the bronchial hygiene techniques are in general poorly documented in the management of the non-cystic fibrosis bronchiectasis, bronchitis or emphysema. The use of the chest physical therapy seems more to do with the interpretation of the imagery and symptomatology. The airway clearance techniques should be individualised according to symptoms, the amount of expectorated mucus and the objectives signs of secretions retention or subjective signs of difficulty expectorating secretions with progression of the disease.

  7. 24 CFR 58.22 - Limitations on activities pending clearance.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Limitations on activities pending clearance. 58.22 Section 58.22 Housing and Urban Development Office of the Secretary, Department of Housing... RESPONSIBILITIES General Policy: Environmental Review Procedures § 58.22 Limitations on activities pending...

  8. Antipyrine clearance during experimental and occupational exposure to toluene

    DEFF Research Database (Denmark)

    Døssing, M; Bælum, Jesper; Lundqvist, G R

    1983-01-01

    into four groups. Eighteen printers and 21 controls were exposed to 100 ppm of toluene during 6.5 hours in an exposure chamber. The remaining 18 printers and 18 controls were exposed to 0 ppm of toluene under similar conditions. The salivary clearance of antipyrine was measured immediately after the stay...

  9. Factors affecting lower calyceal stone clearance after Extracorporeal ...

    African Journals Online (AJOL)

    Objective: Extracorporeal shock wave lithotripsy (ESWL) is one of the most commonly used procedures to remove renal calculi from the lower calyces. The aim of this work is to study the impact of radiological, anatomical and demographic factors on stone clearance after ESWL of lower calyceal calculi. Patients and ...

  10. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Tailshaft clearance; bearing weardown. 61.20-23 Section...; bearing weardown. (a) Water lubricated bearings, other than rubber, must be rebushed as follows: (1) Where the propelling machinery is located amidship, the after stern tube bearing must be rebushed when it is...

  11. Oxygen Tension Beneath Scleral Lenses of Different Clearances.

    Science.gov (United States)

    Giasson, Claude J; Morency, Jeanne; Melillo, Marc; Michaud, Langis

    2017-04-01

    To evaluate the relative partial pressure in oxygen (pO2) at the corneal surface under Boston XO2 scleral lenses (SL) fitted with targeted clearances of 200 and 400 μm (SL200 and SL400). During this prospective study, the right eyes of eight normal subjects were fitted with SL200 and SL400. Clearance, validated after 5 minutes of wear with an optical coherence tomograph, was used with lens thicknesses to calculate transmissibility and estimate pO2. Corneal pO2s were measured with an oxygen electrode after 5 minutes of (1) corneal exposure to calibrating gases with various pO2 or of (2) SL wear. Decays in pO2 were modeled to an exponential. Linear regression between exponent k of these decays and calibrating gas pO2s allowed for the calculation of corneal pO2 under SL. Differences between pO2s beneath SL200 and SL400 were tested with a mixed ANOVA. The estimated transmissibility based on thicknesses and clearances (239.7 ± 34.7; 434.5 ± 33.2 μm) predicted a corneal pO2 of 8.52 ± 0.51 and 6.37 ± 0.28% for SL200 and SL400. These values were close to measured pO2: 9.07 ± 0.86 and 6.19 ± 0.87% (mean ± SEM) (P time, an 18-mm scleral lens fitted with a 400-μm clearance reduces the oxygen tension available to the cornea by 30% compared to a similar lens fitted with a 200-μm clearance after 5 minutes of wear.

  12. Production of plastic scintillation survey meter for clearance verification measurement

    International Nuclear Information System (INIS)

    Tachibana, Mitsuo; Shiraishi, Kunio; Ishigami, Tsutomu; Tomii, Hiroyuki

    2008-03-01

    In the Nuclear Science Research Institute, the decommissioning of various nuclear facilities is carried out according to the plan for meeting the midterm goal of the Japan Atomic Energy Agency (JAEA). An increase in the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas will be expected along with the dismantlement of nuclear facilities in the future. The radiation measurement for releasing controlled areas has been carried out in small-scale nuclear facilities including the JPDR (Japan Power Demonstration Reactor). However, the radiation measurement with an existing measuring device was difficult in effects of radiation from radioactive materials that remains in buried piping. On the other hand, there is no experience that the clearance verification measurement is executed in the JAEA. The generation of a large amount of clearance object will be expected along with the decommissioning of the nuclear facilities in the future. The plastic scintillation survey meter (hereafter, 'PL measuring device') was produced to apply to the clearance verification measurement and the radiation measurement for releasing controlled areas. The basic characteristic test and the actual test were confirmed using the PL measuring device. As a result of these tests, it was found that the evaluation value of radioactivity with the PL measuring device was accuracy equal with the existing measuring device. The PL measuring device has feature of the existing measuring device with a light weight and easy operability. The PL measuring device can correct the gamma ray too. The PL measuring device is effective to the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas. (author)

  13. Comparison of renal clearance of 99mTc-DTPA and inulin 131I-hippurate and PAH as well as creatinine clearance in Wistar-rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Averages and standard deviations of 99m Tc-DTPA and 131 I-hippurate slope clearance were consecutively determined for 56 male Wistar rats, with a body-weight of 271 ± 69 g in a single investigation. Clearance of 99m Tc-DTPA was 17.4 ± 3.4, that of 131 I-hippurate was 34.3 ± 7.2 μl · s -1 per 100 g body weight. For 17 rats inulin and PAH clearances were determined after 3 days with the steady-state method with continuous infusion and 3-4 periods of urine collection. During the same periods endogeneous creatinine clearance was determined. 99m Tc-DTPA slope clearance correlated well with inulin clearance, also the hippurate with the PAH clearance. The high values of the filtration fraction, calculated from radioisotope and chemical methods, and the low PAH extraction of 42% lead to the conclusion, that PAH and hippurate are incompletely eliminated by the rat kidney from plasma and therefore are inadequate for determining renal blood flow in rats. Creatinine clearance was 4.7 ± 1.38 μl · s -1 per 100 g body weight, much lower than that of inulin and 99m Tc-DTPA. Therefore is assumed, that tubular reabsorption of creatinine occurs and creatinine clearance cannot serve for the evaluation of GFR in rats. For this, however, the clearance of 99m Tc-DTPA seems well applicable in Wistar rats. (author)

  14. Comparison of renal clearance of 99mTc-DTPA and inulin, 131I-hippurate and PAH as well as of the creatinine clearance in Wistar rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Order of magnitude and standard deviation of 99m Tc-DTPA and 131 I-hippurate slope clearance were analyzed successively in 56 male Wistar rats. The clearance of 99m Tc-DTPA was 17.4 ± 3.43 μl · s -1 (100 g b-w) -1 , of 131 I-hippurate 34.3 ± 7.21 μl · s -1 (100 g b-w) -1 . In 17 rats inulin and PAH clearances were analyzed by steady state method with permanent infusion and 3 to 4 urine collection periods 3 days later. The endogeneous creatinine clearance was determined within the same periods. The 99m Tc-DTPA slope clearance corresponded to the inulin clearance, as well as the hippurate clearance to the PAH clearance. The high filtration fraction calculated from nuclear medicine and chemical clearance methods and the low PAH extraction (42%) let suggest that PAH and hippurate are eliminated only incompletely from plasma in rat kidney and are unsuitable for determination of renal blood supply in rats. The creatinine clearance with 4.7 ± 1.38 μl · s -1 (100 g b-w) -1 was far beneath the clearance of inulin and 99m Tc-DTPA, supposing that creatinine is reabsorbed tubularly in part and the creatinine clearance can not be used for valuation of the GFR in rats. However, for this the 99m Tc-DTPA clearance in Wistar rats seems to be well suited. (author)

  15. Evaluation of formulas using the serum creatinine level to calculate the optimal dosage of carboplatin.

    Science.gov (United States)

    van Warmerdam, L J; Rodenhuis, S; ten Bokkel Huinink, W W; Maes, R A; Beijnen, J H

    1996-01-01

    Carboplatin is a chemotherapeutic agent frequently used in the treatment of various malignancies. An individual dosing strategy has been recommended to yield the most optimal exposure, expressed as the area under the concentration-time curve (AUC). The formula developed by Calvert et al. (dose = target-AUC x [GFR + 25]) can be used to achieve this. However, due to the inconvenient [51Cr]-ethylenediamine-tetraacetic acid ([51Cr]-EDTA)-based measurement of the glomerular filtration rate (GFR), its application in the clinic has thus far been limited. Chatelut and co-workers have recently proposed a formula to estimate carboplatin clearance using the serum creatinine concentration. We retrospectively tested the Chatelut equation and the Calvert formula using either the creatinine clearance based on 24-h urine collection or the creatinine clearance based on the formula of Cockcroft and Gault. The latter equations were shown to predict the carboplatin clearance reasonably well, although systematic overprediction and underprediction occurred. However, the formula proposed by Chatelut and co-workers had no significant bias and was precise. It is proposed that this formula be used to calculate the optimal carboplatin dosage after prospective validation has been performed.

  16. 78 FR 74175 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2013-12-10

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  17. A comparison of analytic procedures for measurement of fractional dextran clearances

    NARCIS (Netherlands)

    Hemmelder, MH; de Jong, PE; de Zeeuw, D

    Fractional dextran clearances have been extensively used to study glomerular size selectivity. We report on an analysis of different laboratory procedures involved in measuring fractional dextran clearances. The deproteinization of plasma samples by 20% trichloroacetic acid (TCA) revealed a protein

  18. 76 FR 45645 - 10-Day Notice of Proposed Information Collection: Technology Security/Clearance Plans, Screening...

    Science.gov (United States)

    2011-07-29

    ...: Technology Security/Clearance Plans, Screening Records, and Non-Disclosure Agreements ACTION: Notice of... Information Collection: Technology Security/ Clearance Plans, Screening Records, and Non-Disclosure Agreements...: None. Respondents: Business and Nonprofit Organizations, Foreign Governments. Estimated Number of...

  19. Macrophage function as studied by the clearance of 125I-labeled polyvinylpyrrolidone in iron-deficient and iron-replete mice

    International Nuclear Information System (INIS)

    Kuvibidila, S.; Wade, S.

    1987-01-01

    This study evaluated the effects of iron deficiency and iron repletion on in vivo macrophage function determined by the clearance of 125 I-labeled polyvinylpyrrolidone (PVP). Two experiments were done. There were four groups of C57BL/6 female mice in experiment 1: the iron-deficient (ID), pair-fed (PF), control (C) and the high iron (HI) groups. In experiment 2, there were three ID groups (severe to moderate anemia), three PF, one C and four ID groups that were fed adequate iron for 14 (R-14), 7 (R-7), 3 (R-3) days before or on the day of PVP injection (R-0). The overall rate of PVP clearance from blood was lower in ID than in C or PF groups. This clearance is expressed by a constant, K, calculated from natural log (ln) of the cpm and the time postadministration of PVP that blood was drawn. The theoretical individual macrophages function (alpha PVP), derived from K and the weights of body, spleen and liver, was also lower in ID than in C or PF groups. The impairment was most severe with the most severe iron deficiency. Repletion for 7 to 15 d before PVP administration resulted in a partial correction of the clearance. Moderate undernutrition in the PF group had no effect

  20. Positive end-expiratory pressure increases pulmonary clearance of inhaled 99mTc-DTPA in nonsmokers but not in healthy smokers

    International Nuclear Information System (INIS)

    Nolop, K.B.; Braude, S.; Royston, D.; Maxwell, D.L.; Hughes, J.M.B.

    1987-01-01

    Positive end-expiratory pressure (PEEP) is widely used in the treatment of severe pulmonary oedema, although its effects on the clearance of water and small solutes from alveolus to blood are not well characterized. We studied the effect of the application of 10 cmH 2 O of PEEP on the flux of inhaled 99 mTc-diethylene-triamine-penta-acetic acid (DTPA) from lung to blood in six healthy smoking and six nonsmoking subjects. The rate of flux was corrected for possible changes in pulmonary blood volume during PEEP by use of an intravenous injection of 99m Tc-DTPA. The baseline clearance rate (K,%.min -1 ) for nonsmokers was 1.48±0.12 (mean±SE) and increased to 2.40±0.29 during PEEP (p<0.05). In contrast, the mean clearance rate for smokers was 3.26±0.82 at baseline and 3.03±0.82 during PEEP (p=NS). The application of positive end-expiratory pressure appears to increase alveolar solute flux in nonsmokers but not in smokers, suggesting that the pathway for solute clearance in smokers is governed by different rate-limiting steps to those of nonsmokers

  1. Syringe injectable electronics

    Science.gov (United States)

    Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.

    2015-01-01

    Seamless and minimally-invasive three-dimensional (3D) interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating syringe injection and subsequent unfolding of submicrometer-thick, centimeter-scale macroporous mesh electronics through needles with a diameter as small as 100 micrometers. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with > 90% device yield. We demonstrate several applications of syringe injectable electronics as a general approach for interpenetrating flexible electronics with 3D structures, including (i) monitoring of internal mechanical strains in polymer cavities, (ii) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (iii) in vivo multiplexed neural recording. Moreover, syringe injection enables delivery of flexible electronics through a rigid shell, delivery of large volume flexible electronics that can fill internal cavities and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics. PMID:26053995

  2. Syringe-injectable electronics.

    Science.gov (United States)

    Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M

    2015-07-01

    Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.

  3. Clearance of α-aminoisobutyric acid during in-situ perfusion of the guinea pig placenta

    International Nuclear Information System (INIS)

    Kelman, B.J.; Sikov, M.R.

    1983-05-01

    Extensive investigation of the transport of α-aminoisobutyric acid (AIB; a nonmetabolized amino acid) has shown that AIB is actively transported from mother to fetus across the hemochorial placenta of the guinea pig. As a step towards clarifying the relative rolls of active and passive movements of amino acids across the placenta, it would be useful to obtain concurrent measurements of transplacental movements of a substance which crosses the placenta rapidly by simple diffusion (water) and of a substance which is actively transported across the placenta (AIB). In our study, placentas from guinea pigs between 59 and 61 days of gestation were perfused in situ through cannulated umbilical vessels with the maternal circulation left intact. Tritiated water and 14 C-AIB were injected into a maternal jugular vein and maternal blood samples were obtained at 1 to 10 minute intervals; perfusate samples were collected sequentially after one pass through the placenta. Clearance of 14 C-AIB from mother to fetus (AIB/sub MF/) and AIB concentrations in placental tissue, maternal plasma, and perfusate were consistent in magnitude with data obtained by other invetigators who have clearly shown an active transport of AIB in the placenta. On the other hand, in this study AIB/sub MF/ ranged from approximately 50% to 96% of the clearance of 3 H-labeled water from mother to fetus (T/sub MF/) and that changes in AIB/sub MF/ correlated closely with changes in T/sub MF/ in all perfusions. Thus, it appears that AIB/sub MF/ closely paralleled T/sub MF/ and these data suggest that a relatively large component of AIB/sub MF/ is of passive origin in the in situ placenta

  4. 7 CFR 1927.53 - Costs of title clearance and closing of transactions.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Costs of title clearance and closing of transactions... and Loan Closing § 1927.53 Costs of title clearance and closing of transactions. The borrower or the... payment of all costs of title clearance and closing of the transaction and will arrange for payment before...

  5. Online monitoring of dynamic tip clearance of turbine blades in high temperature environments

    Science.gov (United States)

    Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang

    2018-04-01

    Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.

  6. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  7. 48 CFR 245.7101-4 - DD Form 1640, Request for Plant Clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false DD Form 1640, Request for Plant Clearance. 245.7101-4 Section 245.7101-4 Federal Acquisition Regulations System DEFENSE... Forms 245.7101-4 DD Form 1640, Request for Plant Clearance. Use to request plant clearance assistance or...

  8. Whole body and regional clearances of noradrenaline and adrenaline in man

    DEFF Research Database (Denmark)

    Christensen, N J; Galbo, H; Gjerris, Anne Cathrine Roslev

    1984-01-01

    we found no correlation between clearance values based on venous and arterial sampling. In other experiments we measured the influence of physical exercise in young healthy subjects on the clearance rate of plasma adrenaline (A). The clearance of A, which at rest averaged 1.9 l/min tended to increase...

  9. Reactor water injection facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro

    1997-05-02

    A steam turbine and an electric generator are connected by way of a speed convertor. The speed convertor is controlled so that the number of rotation of the electric generator is constant irrespective of the speed change of the steam turbine. A shaft coupler is disposed between the turbine and the electric generator or between the turbine and a water injection pump. With such a constitution, the steam turbine and the electric generator are connected by way of the speed convertor, and since the number of revolution of the electric generator is controlled to be constant, the change of the number of rotation of the turbine can be controlled irrespective of the change of the number of rotation of the electric generator. Accordingly, the flow rate of the injection water from the water injection pump to a reactor pressure vessel can be controlled freely thereby enabling to supply stable electric power. (T.M.)

  10. Plasma clearance and biodistribution of oxidatively modified 99mTc-ß-VLDL in rabbits

    Directory of Open Access Journals (Sweden)

    Silva E.L.

    1997-01-01

    Full Text Available The biodistribution and removal from plasma (measured as fractional clearance rate, FCR, per hour of native and oxidatively modified 99mtechnetium-labeled ß-very low density lipoprotein (99mTc-ß-VLDL were investigated in hypercholesterolemic (HC and control (C three-month old New Zealand rabbits. The intracellular accumulation of ß-VLDL labeled with 99mTc was studied in vitro in THP-1 cells and monocyte-derived macrophages isolated from rabbits. After intravenous injection into C rabbits, copper-oxidized ß-VLDL (99mTc-ox-ß-VLDL was cleared from the circulation faster (0.362 ± 0.070/h than native ß-VLDL (99mTc-nat-ß-VLDL, 0.241 ± 0.070/h. In contrast, the FCR of 99mTc-ox-ß-VLDL in HC rabbits was lower (0.100 ± 0.048/h than that of 99mTc-nat-ß-VLDL (0.163 ± 0.043/h. The hepatic uptake of radiolabeled lipoproteins was lower in HC rabbits (0.114 ± 0.071% injected dose/g tissue for 99mTc-nat-ß-VLDL and 0.116 ± 0.057% injected dose/g tissue for 99mTc-ox-ß-VLDL than in C rabbits (0.301 ± 0.113% injected dose/g tissue for 99mTc-nat-ß-VLDL and 0.305 ± 0.149% injected dose/g tissue for 99mTc-ox-ß-VLDL. The uptake of 99mTc-nat-ß-VLDL and 99mTc-ox-ß-VLDL by atherosclerotic aorta lesions isolated from HC rabbits (99mTc-nat-ß-VLDL: 0.033 ± 0.012% injected dose/g tissue and 99mTc-ox-ß-VLDL: 0.039 ± 0.017% injected dose/g tissue was higher in comparison to that of non-atherosclerotic aortas from C rabbits (99mTc-nat-ß-VLDL: 0.023 ± 0.010% injected dose/g tissue and 99mTc-ox-ß-VLDL: 0.019 ± 0.010% injected dose/g tissue. However, 99mTc-nat-ß-VLDL and 99mTc-ox-ß-VLDL were taken up by atherosclerotic lesions at similar rates. In vitro studies showed that both monocyte-derived macrophages isolated from rabbits and THP-1 macrophages significantly internalized more 99mTc-ox-ß-VLDL than 99mTc-nat-ß-VLDL. These results indicate that in cholesterol-fed rabbits 99mTc-ox-ß-VLDL is slowly cleared from plasma and accumulates in

  11. Semen amyloids participate in spermatozoa selection and clearance.

    Science.gov (United States)

    Roan, Nadia R; Sandi-Monroy, Nathallie; Kohgadai, Nargis; Usmani, Shariq M; Hamil, Katherine G; Neidleman, Jason; Montano, Mauricio; Ständker, Ludger; Röcker, Annika; Cavrois, Marielle; Rosen, Jared; Marson, Kara; Smith, James F; Pilcher, Christopher D; Gagsteiger, Friedrich; Sakk, Olena; O'Rand, Michael; Lishko, Polina V; Kirchhoff, Frank; Münch, Jan; Greene, Warner C

    2017-06-27

    Unlike other human biological fluids, semen contains multiple types of amyloid fibrils in the absence of disease. These fibrils enhance HIV infection by promoting viral fusion to cellular targets, but their natural function remained unknown. The similarities shared between HIV fusion to host cell and sperm fusion to oocyte led us to examine whether these fibrils promote fertilization. Surprisingly, the fibrils inhibited fertilization by immobilizing sperm. Interestingly, however, this immobilization facilitated uptake and clearance of sperm by macrophages, which are known to infiltrate the female reproductive tract (FRT) following semen exposure. In the presence of semen fibrils, damaged and apoptotic sperm were more rapidly phagocytosed than healthy ones, suggesting that deposition of semen fibrils in the lower FRT facilitates clearance of poor-quality sperm. Our findings suggest that amyloid fibrils in semen may play a role in reproduction by participating in sperm selection and facilitating the rapid removal of sperm antigens.

  12. Preparation of iodine-125-labeled iothalamate for renal clearance measurements

    International Nuclear Information System (INIS)

    Rao, S.A.; Herold, T.J.; Dewanjee, M.K.

    1983-01-01

    Iothalamate, a derivative of benzoic acid, is used as a contrast medium for renal function studies, particularly for measurement of glomerular filtration rate. Its chemical composition and clearance properties are similar to those of diatrizoate. The structural differences between these groups of iodinated benzoic acid derivatives are dependent on the groups attached at the 3- and 5-positions of 2,4,6-tri-iodobenzoic acid. The renal clearance of sodium iothalamate in humans closely approximates that of inulin, and it is used as a replacement for inulin in determining glomerular filtration rate. /sup 125/I-labeled iothalamate sodium can be prepared by the exchange-labeling method at pH 4.0. Iothalamate must first be isolated from the contrast medium preparation and purified before radioiodination. After radioiodination, the product is purified by means of precipitation and is then converted to the sodium salt

  13. Quantitative static scintigraphy for the evaluation of mucociliary clearance

    International Nuclear Information System (INIS)

    Maini, C.L.; Marchetti, L.; Giordano, A.; Antonelli Incalzi, R.; Fuso, L.

    1988-01-01

    Mucociliary clearance can be evaluated by radionuclide techniques, but such approaches have been usually implemented only in research-oriented laboratories because of technical difficulties. A very practical radionuclide method is here presented which requires only three static acquisitions after the inhalation of a polydisperse radioaerosol produced by a commercial generator. Data processing is also very simple. The diagnostic performance of the method was tested on a study population of 10 healthy subjects and 10 patients with athrophic bronchitis; a higly significance difference between normal and pathological patients was found. Its simple implementation and diagnostic yield recommend this radionuclide method for the routine assessment of mucociliary clearance also in busy clinical-oriented laboratories

  14. Prognostic value of lactate clearance in severe community acquired pneumonia

    OpenAIRE

    Mohamed, Kamel Abd Elaziz; Ahmed, Dief Abd Elgalil

    2014-01-01

    Introduction: Severe community acquired pneumonia (SCAP) occurs in approximately 18–36% of all CAP and the mortality rate could be as high as 67% in patients with SCAP. Several studies have described a correlation between baseline lactate concentration and mortality of ICU patients. Aim of the work: To follow lactate clearance after admission for 24 h which could be an indicator of outcome in severe community acquired pneumonia. Patients and methods: Forty-six consecutively admitted adu...

  15. Numerical investigation of tip clearance cavitation in Kaplan runners

    Science.gov (United States)

    Nikiforova, K.; Semenov, G.; Kuznetsov, I.; Spiridonov, E.

    2016-11-01

    There is a gap between the Kaplan runner blade and the shroud that makes for a special kind of cavitation: cavitation in the tip leakage flow. Two types of cavitation caused by the presence of clearance gap are known: tip vortex cavitation that appears at the core of the rolled up vortex on the blade suction side and tip clearance cavitation that appears precisely in the gap between the blade tip edge and the shroud. In the context of this work numerical investigation of the model Kaplan runner has been performed taking into account variable tip clearance for several cavitation regimes. The focus is put on investigation of structure and origination of mechanism of cavitation in the tip leakage flow. Calculations have been performed with the help of 3-D unsteady numerical model for two-phase medium. Modeling of turbulent flow in this work has been carried out using full equations of Navier-Stokes averaged by Reynolds with correction for streamline curvature and system rotation. For description of this medium (liquid-vapor) simplification of Euler approach is used; it is based on the model of interpenetrating continuums, within the bounds of this two- phase medium considered as a quasi-homogeneous mixture with the common velocity field and continuous distribution of density for both phases. As a result, engineering techniques for calculation of cavitation conditioned by existence of tip clearance in model turbine runner have been developed. The detailed visualization of the flow was carried out and vortex structure on the suction side of the blade was reproduced. The range of frequency with maximum value of pulsation was assigned and maximum energy frequency was defined; it is based on spectral analysis of the obtained data. Comparison between numerical computation results and experimental data has been also performed. The location of cavitation zone has a good agreement with experiment for all analyzed regimes.

  16. Dextran fractional clearance studies in acute dengue infection.

    Directory of Open Access Journals (Sweden)

    Julie Nguyen-Pouplin

    2011-08-01

    Full Text Available Although increased capillary permeability is the major clinical feature associated with severe dengue infections the mechanisms underlying this phenomenon remain unclear. Dextran clearance methodology has been used to investigate the molecular sieving properties of the microvasculature in clinical situations associated with altered permeability, including during pregnancy and in various renal disorders. In order to better understand the characteristics of the vascular leak associated with dengue we undertook formal dextran clearance studies in Vietnamese dengue patients and healthy volunteers.We carried out serial clearance studies in 15 young adult males with acute dengue and evidence of vascular leakage a during the phase of maximal leakage and b one and three months later, as well as in 16 healthy control subjects. Interestingly we found no difference in the clearance profiles of neutral dextran solutions among the dengue patients at any time-point or in comparison to the healthy volunteers.The surface glycocalyx layer, a fibre-matrix of proteoglycans, glycosaminoglycans, and plasma proteins, forms a complex with the underlying endothelial cells to regulate plasma volume within circumscribed limits. It is likely that during dengue infections loss of plasma proteins from this layer alters the permeability characteristics of the complex; physical and/or electrostatic interactions between the dextran molecules and the glycocalyx structure may temporarily restore normal function, rendering the technique unsuitable for assessing permeability in these patients. The implications for resuscitation of patients with dengue shock syndrome (DSS are potentially important. It is possible that continuous low-dose infusions of dextran may help to stabilize the permeability barrier in patients with profound or refractory shock, reducing the need for repeated boluses, limiting the total colloid volume required. Formal clinical studies should help to assess

  17. Surface code—biophysical signals for apoptotic cell clearance

    International Nuclear Information System (INIS)

    Biermann, Mona; Maueröder, Christian; Brauner, Jan M; Chaurio, Ricardo; Herrmann, Martin; Muñoz, Luis E; Janko, Christina

    2013-01-01

    Apoptotic cell death and the clearance of dying cells play an important and physiological role in embryonic development and normal tissue turnover. In contrast to necrosis, apoptosis proceeds in an anti-inflammatory manner. It is orchestrated by the timed release and/or exposure of so-called ‘find-me’, ‘eat me’ and ‘tolerate me’ signals. Mononuclear phagocytes are attracted by various ‘find-me’ signals, including proteins, nucleotides, and phospholipids released by the dying cell, whereas the involvement of granulocytes is prevented via ‘stay away’ signals. The exposure of anionic phospholipids like phosphatidylserine (PS) by apoptotic cells on the outer leaflet of the plasma membrane is one of the main ‘eat me’ signals. PS is recognized by a number of innate receptors as well as by soluble bridging molecules on the surface of phagocytes. Importantly, phagocytes are able to discriminate between viable and apoptotic cells both exposing PS. Due to cytoskeleton remodeling PS has a higher lateral mobility on the surfaces of apoptotic cells thereby promoting receptor clustering on the phagocyte. PS not only plays an important role in the engulfment process, but also acts as ‘tolerate me’ signal inducing the release of anti-inflammatory cytokines by phagocytes. An efficient and fast clearance of apoptotic cells is required to prevent secondary necrosis and leakage of intracellular danger signals into the surrounding tissue. Failure or prolongation of the clearance process leads to the release of intracellular antigens into the periphery provoking inflammation and development of systemic inflammatory autoimmune disease like systemic lupus erythematosus. Here we review the current findings concerning apoptosis-inducing pathways, important players of apoptotic cell recognition and clearance as well as the role of membrane remodeling in the engulfment of apoptotic cells by phagocytes. (paper)

  18. Oxygen injection facility

    International Nuclear Information System (INIS)

    Ota, Masamoto; Hirose, Yuki

    1998-01-01

    A compressor introduces air as a starting material and sends it to a dust removing device, a dehumidifying device and an adsorption/separation system disposed downstream. The facility of the present invention is disposed in the vicinity of an injection point and installed in a turbine building of a BWR type reactor having a pipeline of a feedwater system to be injected. The adsorbing/separation system comprises an adsorbing vessel and an automatic valve, and the adsorbing vessel is filled with an adsorbent for selectively adsorbing nitrogen. Zeolite is used as the adsorbent. Nitrogen in the air passing through the adsorbing vessel is adsorbed and removed under a pressurized condition, and a highly concentrated oxygen gas is formed. The direction of the steam of the adsorbed nitrogen is changed by an opening/closing switching operation of an automatic valve and released to the atmosphere (the pressure is released). Generated oxygen gas is stored under pressure in a tank, and injected to the pipeline of the feedwater system by an oxygen injection conduit by way of a flow rate control valve. In the adsorbing vessel, steps of adsorption, separation and storage under pressure are repeated successively. (I.N.)

  19. Water injection dredging

    NARCIS (Netherlands)

    Verhagen, H.J.

    2000-01-01

    Some twenty years ago WIS-dredging has been developed in the Netherlands. By injecting water into the mud layer, the water content of the mud becomes higher, it becomes fluid mud and will start to flow. The advantages of this system are that there is no need of transporting the mud in a hopper, and

  20. Botulinum Neurotoxin Injections

    Science.gov (United States)

    ... botulinum neurotoxin as much art as it is science. It is in your best interest to locate the most well-trained and experienced doctor you can find. Before making an appointment to receive botulinum neuro toxin injections, ask the office personnel which doctor ...

  1. Piperacillin and Tazobactam Injection

    Science.gov (United States)

    ... is in a class of medications called penicillin antibiotics. It works by killing bacteria that cause infection. Tazobactam is ... It works by preventing bacteria from destroying piperacillin.Antibiotics ... injection will not work for colds, flu, or other viral infections. Taking ...

  2. Meropenem and Vaborbactam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria. Vaborbactam is in a class ... It works by preventing bacteria from destroying meropenem.Antibiotics such as meropenem and vaborbactam injection will not work for colds, flu, or other viral infections. Taking ...

  3. Cold water injection nozzles

    International Nuclear Information System (INIS)

    Kura, Masaaki; Maeda, Masamitsu; Endo, Takio.

    1979-01-01

    Purpose: To inject cold water in a reactor without applying heat cycles to a reactor container and to the inner wall of a feedwater nozzle by securing a perforated plate at the outlet of the cold water injection nozzle. Constitution: A disc-like cap is secured to the final end of a return nozzle of a control rod drive. The cap prevents the flow of a high temperature water flowing downward in the reactor from entering into the nozzle. The cap is perforated with a plurality of bore holes for injecting cold water into the reactor. The cap is made to about 100 mm in thickness so that the cold water passing through the bore holes is heated by the heat conduction in the cap. Accordingly, the flow of high temperature water flowing downwardly in the reactor is inhibited by the cap from backward flowing into the nozzle. Moreover, the flow of the cold water in the nozzle is controlled and rectified when passed through the bore holes in the cap and then injected into the reactor. (Yoshino, Y.)

  4. Pellet injection in WVIIA

    International Nuclear Information System (INIS)

    Renner, H.; Wuersohing, E.; Weller, A.; Jaeckel, H.; Hartfuss, H.; Hacker, H.; Ringler, H.; Buechl, K.

    1986-01-01

    The results of pellet injection experiments in the Wendelstein VII A stellarator are presented. The injector was a single shot pneumatic gun using deuterium pellets. Experiments were carried out in both ECRH and NI plasmas. Data is shown for plasma density, energy confinement, penetration depth and pellet ablation. Results are compared to a neutral gas shielding model

  5. Magnetron injection gun scaling

    International Nuclear Information System (INIS)

    Lawson, W.

    1988-01-01

    Existing analytic design equations for magnetron injection guns (MIG's) are approximated to obtain a set of scaling laws. The constraints are chosen to examine the maximum peak power capabilities of MIG's. The scaling laws are compared with exact solutions of the design equations and are supported by MIG simulations

  6. RHIC injection kicker impedance

    International Nuclear Information System (INIS)

    Mane, V.; Peggs, S.; Trbojevic, D.; Zhang, W.

    1995-01-01

    The longitudinal impedance of the RHIC injection kicker is measured using the wire method up to a frequency of 3 GHz. The mismatch between the 50 ohm cable and the wire and pipe system is calibrated using the TRL calibration algorithm. Various methods of reducing the impedance, such as coated ceramic pipe and copper strips are investigated

  7. SPS injection kicker magnet

    CERN Document Server

    1975-01-01

    One of the first-generation SPS injection kicker magnets. Lifting the tank-lid reveals the inner structure. For a more detailed description see 7502072X. See also 7502074X and Annual Report 1975, p.162. To the left: Roland Tröhler; to the right: Giacomo Busetta.

  8. RENAL CLEARANCE AND URINARY EXCRETION OF CIPROFLOXACIN IN GOATS

    Directory of Open Access Journals (Sweden)

    Z. IQBAL, I. JAVED, B. ASLAM, F. MUHAMMAD AND I. U. JAN

    2007-10-01

    Full Text Available The renal clearance and urinary excretion of ciprofloxacin were investigated in eight healthy female goats. In each animal, ciprofloxacin was administered intramuscularly at the rate of 5 mg/kg body weight. Following drug administration, blood and urine samples were collected at different time intervals and analyzed for ciprofloxacin and creatinine. High performance liquid chromatography (HPLC was used to determine the drug concentration in the plasma and urine. The value of diuresis after single administration of ciprofloxacin was 0.073 ± 0.014 ml/min/kg. Mean (± SE values for renal clearance of creatinine and ciprofloxacin were 1.870 ± 0.385 and 0.982 ± 0.166 ml/min/kg, respectively. The ratio between the renal clearance of ciprofloxacin and that of creatinine remained less than one, which was indicative of back diffusion. The mean (± SE value for the cumulative percent of ciprofloxacin dose excreted at 10 hours following its intramuscular administration was 13.03 ± 2.07. Based on these results, it was evident that besides glomerular filtration, renal handling of drug involved back diffusion also. It was concluded that in local goats glomerular filtration rate (GFR was lower than that reported for their foreign counterparts.

  9. Losses and blade tip clearance for a centrifugal compressor

    Directory of Open Access Journals (Sweden)

    Oana DUMITRESCU

    2018-06-01

    Full Text Available The present paper presents the numerical analysis for a transonic centrifugal compressor using steady state CFD. The blade tip clearance effect over the position of shock waves, tip losses and the performances of the impeller are studied. Numerical simulations have been performed using RANS modelling, with the k-omega SST turbulence model (Shear Stress Transport. Eight cases were taken into consideration for the impeller with the following blade tip clearances values: 0 mm, 0.1 mm, 0.3 mm, 0.4 mm, 0.5mm, 0.7 mm, 1 mm, 2 mm, at the same operating conditions. For the entire stage only seven cases were studied, without the value for 0.1 mm because of its abnormal behaviour, as can be seen in the case of the impeller simulations. Results showed that the position of the shock wave does not change with the increase of the tip clearance. Aerodynamic losses due to shock wave, secondary flow and turbulence can be seen in the polytropic efficiency of the centrifugal impeller and the difference between the two extreme cases is about 3.2 %.

  10. Railway clearance intrusion detection method with binocular stereo vision

    Science.gov (United States)

    Zhou, Xingfang; Guo, Baoqing; Wei, Wei

    2018-03-01

    In the stage of railway construction and operation, objects intruding railway clearance greatly threaten the safety of railway operation. Real-time intrusion detection is of great importance. For the shortcomings of depth insensitive and shadow interference of single image method, an intrusion detection method with binocular stereo vision is proposed to reconstruct the 3D scene for locating the objects and judging clearance intrusion. The binocular cameras are calibrated with Zhang Zhengyou's method. In order to improve the 3D reconstruction speed, a suspicious region is firstly determined by background difference method of a single camera's image sequences. The image rectification, stereo matching and 3D reconstruction process are only executed when there is a suspicious region. A transformation matrix from Camera Coordinate System(CCS) to Track Coordinate System(TCS) is computed with gauge constant and used to transfer the 3D point clouds into the TCS, then the 3D point clouds are used to calculate the object position and intrusion in TCS. The experiments in railway scene show that the position precision is better than 10mm. It is an effective way for clearance intrusion detection and can satisfy the requirement of railway application.

  11. Characterization and Clearance of m/s Sigyn

    International Nuclear Information System (INIS)

    Jiselmark, Jonatan; Vreede, Patrick

    2016-01-01

    M/s Sigyn was a 2044 ton ship that transported contaminated material between 1982 and 2013. Most of the transports were with spent nuclear fuel between Swedish nuclear power plants and the Swedish fuel repository, Clab. In addition to spent fuel, m/s Sigyn also transported big contaminated components, from nuclear power plants in Europe, to Studsvik for analysis or decontamination and melting. She also transported components from Swedish nuclear power plants to final disposal of short lived waste, SFR. Even though all transported items have been cleaned, checked and wrapped with plastics, some activity ended up as contamination onboard. In December 2013 it was decided that m/s Sigyn was subject for decommissioning due to her age. This Paper describes the method in which the activity onboard m/s Sigyn was characterized and clearance levels were calculated. This method for radiological characterization and clearance has recently been developed in Sweden, the method is efficient in that it does not need a big pre characterization survey. Only the nuclide distribution and history of the object, is needed to start the final survey. In the future there will be further development of the method, making it possible to reduce the number of measurements even more. This will further optimize the method and reduce the cost for final surveys and clearance. (authors)

  12. Rate-Based Model Predictive Control of Turbofan Engine Clearance

    Science.gov (United States)

    DeCastro, Jonathan A.

    2006-01-01

    An innovative model predictive control strategy is developed for control of nonlinear aircraft propulsion systems and sub-systems. At the heart of the controller is a rate-based linear parameter-varying model that propagates the state derivatives across the prediction horizon, extending prediction fidelity to transient regimes where conventional models begin to lose validity. The new control law is applied to a demanding active clearance control application, where the objectives are to tightly regulate blade tip clearances and also anticipate and avoid detrimental blade-shroud rub occurrences by optimally maintaining a predefined minimum clearance. Simulation results verify that the rate-based controller is capable of satisfying the objectives during realistic flight scenarios where both a conventional Jacobian-based model predictive control law and an unconstrained linear-quadratic optimal controller are incapable of doing so. The controller is evaluated using a variety of different actuators, illustrating the efficacy and versatility of the control approach. It is concluded that the new strategy has promise for this and other nonlinear aerospace applications that place high importance on the attainment of control objectives during transient regimes.

  13. Dysregulation of Nutrient Sensing and CLEARance in Presenilin Deficiency

    Directory of Open Access Journals (Sweden)

    Kavya Reddy

    2016-03-01

    Full Text Available Attenuated auto-lysosomal system has been associated with Alzheimer disease (AD, yet all underlying molecular mechanisms leading to this impairment are unknown. We show that the amino acid sensing of mechanistic target of rapamycin complex 1 (mTORC1 is dysregulated in cells deficient in presenilin, a protein associated with AD. In these cells, mTORC1 is constitutively tethered to lysosomal membranes, unresponsive to starvation, and inhibitory to TFEB-mediated clearance due to a reduction in Sestrin2 expression. Normalization of Sestrin2 levels through overexpression or elevation of nuclear calcium rescued mTORC1 tethering and initiated clearance. While CLEAR network attenuation in vivo results in buildup of amyloid, phospho-Tau, and neurodegeneration, presenilin-knockout fibroblasts and iPSC-derived AD human neurons fail to effectively initiate autophagy. These results propose an altered mechanism for nutrient sensing in presenilin deficiency and underline an importance of clearance pathways in the onset of AD.

  14. Kupffer cell complement receptor clearance function and host defense.

    Science.gov (United States)

    Loegering, D J

    1986-01-01

    Kupffer cells are well known to be important for normal host defense function. The development of methods to evaluate the in vivo function of specific receptors on Kupffer cells has made it possible to assess the role of these receptors in host defense. The rationale for studying complement receptors is based on the proposed important role of these receptors in host defense and on the observation that the hereditary deficiency of a complement receptor is associated with recurrent severe bacterial infections. The studies reviewed here demonstrate that forms of injury that are associated with depressed host defense including thermal injury, hemorrhagic shock, trauma, and surgery also cause a decrease in complement receptor clearance function. This decrease in Kupffer cell receptor clearance function was shown not to be the result of depressed hepatic blood flow or depletion of complement components. Complement receptor function was also depressed following the phagocytosis of particulates that are known to depress Kupffer cell host defense function. Endotoxemia and bacteremia also were associated with a depression of complement receptor function. Complement receptor function was experimentally depressed in uninjured animals by the phagocytosis of IgG-coated erythrocytes. There was a close association between the depression of complement receptor clearance function and increased susceptibility to the lethal effects of endotoxin and bacterial infection. These studies support the hypotheses that complement receptors on Kupffer cells are important for normal host defense and that depression of the function of these receptors impairs host defense.

  15. Turbine Engine Clearance Control Systems: Current Practices and Future Directions

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.

    2002-01-01

    Improved blade tip sealing in the high pressure compressor (HPC) and high pressure turbine (HPT) can provide dramatic reductions in specific fuel consumption (SFC), time-on-wing, compressor stall margin, and engine efficiency as well as increased payload and mission range capabilities. Maintenance costs to overhaul large commercial gas turbine engines can easily exceed $1M. Engine removal from service is primarily due to spent exhaust gas temperature (EGT) margin caused mainly by the deterioration of HPT components. Increased blade tip clearance is a major factor in hot section component degradation. As engine designs continue to push the performance envelope with fewer parts and the market drives manufacturers to increase service life, the need for advanced sealing continues to grow. A review of aero gas turbine engine HPT performance degradation and the mechanisms that promote these losses are discussed. Benefits to the HPT due to improved clearance management are identified. Past and present sealing technologies are presented along with specifications for next generation engine clearance control systems.

  16. The provision of clearances accuracy in piston - cylinder mating

    Science.gov (United States)

    Glukhov, V. I.; Shalay, V. V.

    2017-08-01

    The paper is aimed at increasing the quality of the pumping equipment in oil and gas industry. The main purpose of the study is to stabilize maximum values of productivity and durability of the pumping equipment based on the selective assembly of the cylinder-piston kinematic mating by optimization criterion. It is shown that the minimum clearance in the piston-cylinder mating is formed by maximum material dimensions. It is proved that maximum material dimensions are characterized by their own laws of distribution within the tolerance limits for the diameters of the cylinder internal mirror and the outer cylindrical surface of the piston. At that, their dispersion zones should be divided into size groups with a group tolerance equal to half the tolerance for the minimum clearance. The techniques for measuring the material dimensions - the smallest cylinder diameter and the largest piston diameter according to the envelope condition - are developed for sorting them into size groups. Reliable control of the dimensions precision ensures optimal minimum clearances of the piston-cylinder mating in all the size groups of the pumping equipment, necessary for increasing the equipment productivity and durability during the production, operation and repair processes.

  17. Smoking produced mucus and clearance of particulates in the lung

    International Nuclear Information System (INIS)

    Sterling, T.D.; Poland, T.M.

    1992-01-01

    Some studies of miners have shown a lesser relative lung-cancer risk for smokers than for nonsmokers. For example, experiments by Cross and associates with dogs have shown an apparent protective effect of cigarette smoke against radon-daughter and dust exposure. One reason for these changes may be the thickened mucus layer in the tracheobronchial region of smokers. Physiological changes in the lung due to smoking may decrease the effects of radioactive particles in cancers in the bronchial region by apparently promoting faster clearance, in that region, of radioactive particles and by decreasing the radiation dose through reduced penetration to the sensitive basal epithelial cells. Because of the short half-life of radon daughters, even if there is possible tobacco-related delay of particle clearance from the alveolar region it cannot affect radon clearance. Therefore, the possible mitigating effect of tobacco on radon-produced cancer appears to be limited to the tracheobronchial region. It would be of value to a number of occupations if the same changes in the lungs due to smoking could be produced in exposed workers in the absence of cigarette-smoking. Beta-carotene and vitamin A, which affect maintenance and secretion of the mucosal lining, appear to thicken mucus, thereby providing protection against radon-induced lung cancers that is similar to smoking-related changes in the lung

  18. Effect of Guide Vane Clearance Gap on Francis Turbine Performance

    Directory of Open Access Journals (Sweden)

    Ravi Koirala

    2016-04-01

    Full Text Available Francis turbine guide vanes have pivoted support with external control mechanism, for conversion of pressure to kinetic energy and to direct them to runner vanes. This movement along the support is dependent on variation of load and flow (operating conditions. Small clearance gaps between facing plates and the upper and lower guide vane tips are available to aid this movement, through which leakage flow occurs. This secondary flow disturbs the main flow stream, resulting performance loss. Additionally, these increased horseshoe vortex, in presence of sand, when crosses through the gaps, both the surfaces are eroded. This causes further serious effect on performance and structural property by increasing gaps. This paper discusses the observation of the severity in hydropower plants and effect of clearance gaps on general performance of the Francis turbine through computational methods. It also relates the primary result with the empirical relation for leakage flow prediction. Additionally, a possible method to computationally estimate thickness depletion has also been presented. With increasing clearance gap, leakage increases, which lowers energy conversion and turbine efficiency along with larger secondary vortex.

  19. Quantitative assessment of caffeine partial clearances in man.

    Science.gov (United States)

    Lelo, A; Miners, J O; Robson, R A; Birkett, D J

    1986-01-01

    Five subjects who participated in an earlier study (Lelo et al., 1986b) of the comparative pharmacokinetics of caffeine (CA) and its primary monodemethylated metabolites paraxanthine (PX), theobromine (TB) and theophylline (TP) were administered CA to steady-state. Using areas under the plasma concentration-time curves for each of the dimethylxanthines derived from CA in the steady-state study and individual plasma clearances of PX, TB and TP determined in the previous study, the fractional conversion of CA to PX, TB and TP and the individual partial clearances of CA have been defined. The mean (+/- s.d.) fractional conversion of CA to PX, TB and TP was 79.6 +/- 21.0%, 10.8 +/- 2.4% and 3.7 +/- 1.3%, respectively. When only demethylation pathways are considered PX, TB and TP accounted for 83.9 +/- 5.4%, 12.1 +/- 4.1% and 4.0 +/- 1.4%, respectively of the CA demethylations. The mean partial clearance of CA to PX was approximately 8-fold and 23-fold greater than those to TB and TP respectively. These data confirm earlier reports that PX is the major metabolite of CA in humans but suggest that PX formation is quantitatively more important than previously believed. PMID:3756066

  20. Dynamic Studies of Lung Fluid Clearance with Phase Contrast Imaging

    International Nuclear Information System (INIS)

    Kitchen, Marcus J.; Williams, Ivan; Irvine, Sarah C.; Morgan, Michael J.; Paganin, David M.; Lewis, Rob A.; Pavlov, Konstantin; Hooper, Stuart B.; Wallace, Megan J.; Siu, Karen K. W.; Yagi, Naoto; Uesugi, Kentaro

    2007-01-01

    Clearance of liquid from the airways at birth is a poorly understood process, partly due to the difficulties of observing and measuring the distribution of air within the lung. Imaging dynamic processes within the lung in vivo with high contrast and spatial resolution is therefore a major challenge. However, phase contrast X-ray imaging is able to exploit inhaled air as a contrast agent, rendering the lungs of small animals visible due to the large changes in the refractive index at air/tissue interfaces. In concert with the high spatial resolution afforded by X-ray imaging systems (<100 μm), propagation-based phase contrast imaging is ideal for studying lung development. To this end we have utilized intense, monochromatic synchrotron radiation, together with a fast readout CCD camera, to study fluid clearance from the lungs of rabbit pups at birth. Local rates of fluid clearance have been measured from the dynamic sequences using a single image phase retrieval algorithm

  1. Clearance of thallium-201 from the peripheral blood: comparison of immediate and standard thallium-201 reinjection

    International Nuclear Information System (INIS)

    Eck-Smit, B.L.F. van; Wall, E.E. van der; Verhoeven, P.P.A.M.; Poots, S.; Zwinderman, A.H.; Pauwels, E.K.J.

    1996-01-01

    We investigated whether the kinetics of thallium-201 would differ between the standard stress-redistribution-reinjection approach and the stress-immediate reinjection approach. In 53 patients with undiagnosed chest pain, 75 MBq (2 mCi) 201 Tl was injected at maximal exercise. In 26 patients (group I), 37 MBq (1 mCi) 201 Tl was reinjected immediately after completing the exercise images and in 27 patients (group II), 37 MBq (1 mCi) 201 Tl was reinjected after completing 3-h redistribution images. Mean peak 201 Tl blood activity after exercise was 17.7±12.5 kBq/ml (4.8±3.4 mCi/ml) for group I versus 16.4±9.2 kBq/ml (4.4±2.5 mCi/ml) for group II (NS). The relative increase in 201 Tl blood activity after reinjection of half the initial dose [37 MBq (1 mCi)] exceeded 50% of the initial peak in both groups. The relative amount of 201 Tl delivered to the myocardium was assessed by the area under the curve after both exercise and reinjection, and was 117%±72% for group I and 112%±73% for group II (NS). Blood clearance of 201 Tl was at least biexponential. Mean early decay constants (λ 1 ) after exercise and reinjection were 0.30±0.18 min -1 and 0.22±0.046 min -1 resp. for group I, and 0.30±0.12 min -1 and 0.24±0.07 min -1 resp. for group II. For both procedures no significant differences were found between λ 1 after exercise and λ 1 after injection. The mean late clearance (λ 2 ) from the blood was 0.032±0.056 min -1 and 0.012±0.012 min -1 resp. for group I, and 0.036±0.030 min -1 and 0.014±0.014 min -1 resp. for group II. Also, no significant differences were found between λ 2 after exercise for both groups and between λ 2 after reinjection for both groups. (orig./MG)

  2. Radiotracer injections through microfilters

    International Nuclear Information System (INIS)

    Huber, H.; Maschek, G.; Pichler, R.; Giesen, I.; Hatzl-Griesenhofer, M.; Maschek, W.

    2002-01-01

    Full text: Problems with the injection of radiotracers ( 99m Tc-HAMS, 99m Tc-DPD) to infants when administered through polar-filter-protected venous pathways caused us to get a closer look of what happens to a tracer in such a system. We simulated injections of the tracers mainly used at our institution in an in-vitro array and measured full and empty tracer syringes, filters (0.2 μm micropores) and the post-filter receptacle of the radioactivity. We calculated the percentage of filter-trapped activity and of activity in the receptacle. For several tracers we repeated this process with a neutral filter of the same pore size to get a comparison between the behavior in polarized and electrically inert filters. In general injection of a soluble radiotracer through a polar filter system means a dose loss in the filter of about 10 %, up to the tracer molecule size of IgG-antibodies. Suspended tracers, which consist of comparatively large particles, like RES- or pulmonary perfusion markers, are blocked by the filter, as can be foreseen with a particle size of >> 0.2 μm. DMSA and DPD (a biphosphonate), although both being soluble and rather small molecules, were blocked by the polar filter to a high extent, and by the neutral filter to a much lower, almost neglectable degree. The conclusions are: if possible avoid any use of a filter in your tracer injection pathway. Never use a filter with bone scan or DMSA applications. When doing uptake calculations you have to add the filter counts to the empty syringe value in the formula. If you cannot avoid to inject the radiotracer through a filter you have to replace the filter afterwards and treat the used filter as radioactive waste. The polarity of the filter material might severely affect retention of radiotracer in the filter. (author)

  3. Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.

    2003-01-01

    Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

  4. Cystatin C as a predictor of mortality in elderly patients with chronic kidney disease.

    Science.gov (United States)

    Bevc, Sebastjan; Hojs, Nina; Knehtl, Maša; Ekart, Robert; Hojs, Radovan

    2018-06-18

    The prevalence of chronic kidney disease (CKD) in the elderly is high. Serum cystatin C is an accurate marker of kidney function and it also has prognostic utility in CKD patients. The aim of our study was to determine the prediction of serum cystatin C and other markers of kidney function on long-term survival in elderly CKD patients. Fifty eight adult Caucasian patients, older than 65 years, without known malignancy, thyroid disease and/or not on steroid therapy were enrolled in the study. In each patient, 51 CrEDTA clearance, serum creatinine, serum cystatin C, and estimated glomerular filtration rate using different equations were determined on the same day and patients were then followed for 11 years or until their death. The means are as follows: 51 CrEDTA clearance 53.3 ± 17.4 ml/min/1.73 m 2 , serum creatinine 1.62 ± 0.5 mg/dl, serum cystatin C 1.79 ± 0.5 mg/l, Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) creatinine equation 40.1 ± 14 ml/min/1.73 m 2 , Berlin Initiative Study 2 (BIS2) equation 38.9 ± 10.7 ml/min/1.73 m 2 , full age spectrum (FAS) creatinine equation 43.8 ± 13.8 ml/min/1.73 m 2 , FAS cystatin C equation 40.1 ± 11.7 ml/min/1.73 m 2 . In the follow up period, 47 (81%) patients died. Cox regression analysis showed different hazard ratios (HRs) for death: for 51 CrEDTA clearance HR 1.022 (95% CI 1.004-1.042; p = .015), serum creatinine HR 1.013 (95% CI 1.006-1.019; p = .001), serum cystatin C HR 2.028 (95% CI 1.267-3.241; p = .003), CKD-EPI creatinine equation HR 1.048 (95% CI 1.019-1.076; p = .001), BIS2 equation HR 1.055 (95% CI 1.021-1.088; p = .001), FAS creatinine equation HR 1.046 (95% CI 1.017-1.074; p = .001), FAS cystatin C equation HR 1.039 (95% CI 1.010-1.071; p = .009). Our results showed the highest HR for serum cystatin C among kidney function markers for prediction of outcome in elderly CKD patients.

  5. Effects of radiosensitising agent nicotinamide on relative tissue perfusion and kidney junction in C3H mice

    International Nuclear Information System (INIS)

    Honess, D.J.; Bleehen, N.M.

    1993-01-01

    Nicotinamide is an effective radiosensitiser of murine tumours, functioning by improving tumour perfusion by decreasing the proportion of intermittently closed capillaries. The effect of nicotinamide on relative tissue perfusion of RIF-1 tumour and normal skin, muscle, lung, liver, kidney and spleen were investigated using the 86 Rb extraction technique. A dose of 1000 mg/kg was shown to have transient effects on tumour, skin and lung perfusion but to have sustained effects on muscle (a drop to 80% of control), liver, kidney and spleen (with increased ranging from 165% to 280% of control) from 0.5 to 4 h after treatment i.e. during the period of maximum radiosensitisation. These increases were evident at doses as low as 100 mg/kg. The data suggest that the radiosensitisation induced by nicotinamide in the mouse may be associated with these perfusion changes. Nicotinamide was also shown to have a substantial inhibitory effect on renal function, inhibiting 51 CrEDTA clearance by a factor (± 2 SE) of 2.56 ± 0.19 and 125 I-iodohippurate clearance by a factor of 2.07 ± 0.45 at 1000 mg/kg. These effects were shown to be dose-related, and to be evident at doses from 400 mg/kg upwards. This suggests that nicotinamide potentiation of co-administered cytotoxic agents may be mediated by reduced renal clearance of the cytotoxic drug, thus increasing the plasma half-life. (author)

  6. Effect of metabolic regulation on renal leakiness to dextran molecules in short-term insulin-dependent diabetics

    DEFF Research Database (Denmark)

    Parving, H H; Rutili, F; Granath, K

    1979-01-01

    Renal clearance of dextran of two ranges of molecular size and glomerular filtration rate (GFR, 51Cr-EDTA) were measured in seven short-term insulin-dependent diabetics (mean age 25 years). Measurements were carried out in the same patient during good and poor metabolic regulation (plasma glucose......, mean +/- SEM, 6.5 +/- 0.9 and 14.8 +/- 1.5 mmol/l, respectively). GFR was elevated in all patients during poor metabolic regulation (119 +/- 6 ml/min/1.73 m2, versus 99 +/- 2 ml/min/1.73 m2 during good control, p less than 0.01). The average renal clearance of dextran with molecular weights ranging...... from 25,000 to 35,000 and 35,000 to 45,000 increased during poor metabolic regulation from 14.8 +/- 0.8 to 19.8 +/- 1.8 ml/min/1.73 m2, and 5.2 +/- 0.3 to 6.8 +/- 0.6 ml/min/1.73 m2, respectively (p less than 0.05). The elevated GFR and renal dextran clearance found during poor metabolic regulation...

  7. Injection-controlled laser resonator

    Science.gov (United States)

    Chang, J.J.

    1995-07-18

    A new injection-controlled laser resonator incorporates self-filtering and self-imaging characteristics with an efficient injection scheme. A low-divergence laser signal is injected into the resonator, which enables the injection signal to be converted to the desired resonator modes before the main laser pulse starts. This injection technique and resonator design enable the laser cavity to improve the quality of the injection signal through self-filtering before the main laser pulse starts. The self-imaging property of the present resonator reduces the cavity induced diffraction effects and, in turn, improves the laser beam quality. 5 figs.

  8. Ceramic injection molding

    International Nuclear Information System (INIS)

    Agueda, Horacio; Russo, Diego

    1988-01-01

    Interest in making complex net-shape ceramic parts with good surface finishing and sharp tolerances without machining is a driving force for studying the injection molding technique. This method consists of softhening the ceramic material by means of adding some plastic and heating in order to inject the mixture under pressure into a relatively cold mold where solidification takes place. Essentially, it is the same process used in thermoplastic industry but, in the present case, the ceramic powder load ranges between 80 to 90 wt.%. This work shows results obtained from the fabrication of pieces of different ceramic materials (alumina, barium titanate ferrites, etc.) in a small scale, using equipments developed and constructed in the laboratory. (Author) [es

  9. Gaseous poison injection device

    International Nuclear Information System (INIS)

    Kubota, Ryuji; Sugisaki, Toshihiko; Inada, Ikuo.

    1983-01-01

    Purpose: To rapidly control the chain reaction due to thermal neutrons in a reactor core by using gaseous poisons as back-up means for control rod drives. Constitution: Gaseous poisons having a large neutron absorption cross section are used as back-up means for control rod drives. Upon failure of control rod insertion, the gaseous poisons are injected into the lower portion of the reactor core to control the reactor power. As the gaseous poisons, vapors at a high temperature and a higher pressure than that of the coolants in the reactor core are injected to control the reactor power due to the void effects. Since the gaseous poisons thus employed rapidly reach the reactor core and form gas bubbles therein, the deccelerating effect of the thermal neutrons is decreased to reduce the chain reaction. (Moriyama, K.)

  10. Accelerated blood clearance phenomenon upon cross-administration of PEGylated nanocarriers in beagle dogs

    Directory of Open Access Journals (Sweden)

    Wang CL

    2015-05-01

    Full Text Available Chunling Wang,1 Xiaobo Cheng,2 Yuqing Su,1 Ying Pei,3 Yanzhi Song,1 Jiao Jiao,1 Zhenjun Huang,1 Yanfei Ma,1 Yinming Dong,1 Ying Yao,1 Jingjing Fan,1 Han Ta,1 Xinrong Liu,1 Hui Xu,1 Yihui Deng1 1College of Pharmacy, Shenyang Pharmaceutical University, Shenyang, People’s Republic of China; 2Deli Wei Biological Technology Co, Ltd, Beijing, People’s Republic of China; 3Shenyang Women’s and Children’s Hospital, Shenyang, People’s Republic of China Abstract: The cross-administration of nanocarriers modified by poly(ethylene glycol (PEG, named PEGylated nanocarriers, a type of combination therapy, is becoming an increasingly important method of long-term drug delivery, to decrease side effects, avoid multidrug resistance, and increase therapeutic efficacy. However, repeated injections of PEGylated nanocarriers induces the accelerated blood clearance (ABC phenomenon, prevents long circulation, and can cause adverse effects owing to alterations in the biodistribution of the drug. Although the nature of the ABC phenomenon that is induced by repeated injections of PEGylated nanocarriers has already been studied in detail, there are few reports on the immune response elicited by the cross-administration of PEGylated nanocarriers. In this study, we investigated the ABC phenomenon induced by the intravenous cross-administration of various PEGylated nanocarriers, including PEGylated liposomes (PL, PEG micelles (PM, PEGylated solid lipid nanoparticles (PSLN, and PEGylated emulsions (PE, in beagle dogs. The results indicated that the magnitude of the immune response elicited by the cross-administration was in the following order (from the strongest to the weakest: PL, PE, PSLN, PM. It is specifically PEG in the brush structure that elicits a significant immune response, in both the induction phase and the effectuation phase. Furthermore, the present study suggests that there is a considerable difference between the effect of repeated injections and

  11. SPEAR 3 INJECTION KICKER

    International Nuclear Information System (INIS)

    2002-01-01

    The design of the SPEAR 3 injection kicker system is presented. This system will include three kicker magnets and their associated pulsers. The magnet design is based on the DELTA kicker magnets, which present a low RF impedance to the beam, and are relatively straight-forward to construct. The pulsers use cascaded IGBT stages that are based on the modulator pulsers developed by a SLAC/LLNL collaboration for the NLC. Design considerations and the results of prototype tests will be discussed

  12. Gallium arsenide injection lasers

    International Nuclear Information System (INIS)

    Thompson, G.H.B.

    1975-01-01

    The semiconductor injection laser includes a thin inner GaAs p-n junction layer between two outer GaAlAs layers which are backed by further thin outer GaAlAs layers with a heavier doping of AlAs. This reduces optical losses. Optical energy is further confined within the inner layers and the lasing threshold reduced by added outer GaAs layers of low electrical and thermal resistivity

  13. Hydrogen pellet injection device

    International Nuclear Information System (INIS)

    Kanno, Masahiro.

    1992-01-01

    In a hydrogen pellet injection device, a nozzle block having a hydrogen gas supply channel is disposed at the inner side of a main cryogenic housing, and an electric resistor is attached to the block. Further, a nozzle block and a hydrogen gas introduction pipe are attached by way of a thermal insulating spacer. Electric current is supplied to the resistor to positively heat the nozzle block and melt remaining solid hydrogen in the hydrogen gas supply channel. Further, the effect of temperature elevation due to the resistor is prevented from reaching the side of the hydrogen gas introduction pipe by the thermal insulation spacer. That is, the temperature of the nozzle block is directly and positively elevated, to melt the solid hydrogen rapidly. Preparation operation from the injection of the hydrogen pellet to the next injection can be completed in a shorter period of time compared with a conventional case thereby enabling to make the test more efficient. Further, only the temperature of the nozzle block is elevated with no effect of temperature elevation due to the resistor to other components by the thermal insulation flange. (N.H.)

  14. Clearance rates of jellyfish and their potential predation impact on zooplankton and fish larvae in a neritic ecosystem (Limfjorden, Denmark)

    DEFF Research Database (Denmark)

    Hansson, L. J.; Moeslund, O.; Kiørboe, Thomas

    2005-01-01

    clearance potential were given assumed clearance rate values, but the collective predation potential by these species was evaluated to be small. Hydromedusae dominated numerically and had their highest potential clearance impact in spring, but overall jellyfish clearance potential on copepods was low during...

  15. Blood flow to palatal mucosal grafts in mandibular labial vestibuloplasty measured by 133Xe clearance technique

    International Nuclear Information System (INIS)

    Basa, S.; Ercan, M.T.; Aras, T.; Araz, K.

    1987-01-01

    In 11 subjects, the blood flow to alveolar and palatal mucosa was measured by intra-mucosal injection of 133 Xe. Later, mandibular labial vestibuloplasty was performed with mucosal grafts in all of them. The use of a stent was omitted. The subjects were followed by clinical observation and by blood flow measurements up to 6 weeks postoperatively. At certain intervals (3 and 10 days, 4 and 6 weeks), 133 Xe clearance in the graft was determined. Under normal conditions, the mean blood flows to the alveolar and to palatal mucosa were 53.2±12.9 and 58.3±3.5 ml/100 g/min, respectively. The difference between them was statistically insignificant (P>0.05). The graft blood flow was 13.4±3.2 and 21.7±15.0 ml/100 g/min on the 3rd and 10th days after operation. The decrease in both compared to normal values was statistically significant (P<0.001). The blood flow reached almost normal levels (46.2±16.9 ml/100 g/min) and above (63.9±9.7 ml/100 g/min; P<0.05) at 4 and 6 weeks after operation, respectively. These results were in agreement with the clinical observations. The palatal donor area healed in 3-5 weeks. The graft showed complete adaptation with the surrounding tissue and healing in 4-6 weeks. Our results also indicated that injections in the graft do not retard graft healing. (author)

  16. Pulmonary clearance of 99mTc-DTPA and 99mTc-albumin in rabbits with surfactant dysfunction and lung injury

    International Nuclear Information System (INIS)

    Nilsson, K.; Wollmer, P.

    1992-01-01

    We measured the pulmonary clearance of inhaled 99m Tc-DTPA and 99m Tc-albumin in rabbits with surfacant dysfunction induced by dioctyl sodium sulphosuccinate and in rabbits with lung injury induced by oleic acid. After inhalation of 99m Tc-albumin in ten animals, clearance of the tracer from the lungs was monitored for 90 min. The first 30 min was a control period. Dioctyl sodium sulphosuccinate was then administered in aerosol and after another 30 min oleic acid was injected intravenously. Ten other rabbits were given 99m Tc-DTPA, and clearance was externally recorded for 60 min. Five animals inhaled detergent aerosol and five animals were given oleic acid intravenously after 30 min. Airway pressures, tidal volume, and arterial blood gases were measured before and after each intervention. The half-life of 99m Tc-albumin in the lung was 442 ± 123 min during the control period, 363 ± 52 min after detergent administration, and 134 ± 18 min after oleic acid administration. The half-life of 99m Tc-DTPA was 94 ± 16 min before and 10 ± 0.6 min after detergent administration and 75 ± 12 min before and 18 ± 1.8 min after oleic acid administration. Gas exchange was not affected by administration of dioctyl sodium sulphosuccinate but markedly impaired after injection of oleic acid. Compliance of the respiratory system remained unaffected by detergent but decreased after injection of oleic acid. The results indicate that the rate limiting factors for the alveolo-capillary transfer of 99m Tc-albumin and 99m Tc-DTPA are different. Surfactant dysfunction affects the transfer of 99m Tc-DTPA but not 99m Tc-albumin. (author)

  17. Penicillin G (Potassium, Sodium) Injection

    Science.gov (United States)

    Penicillin G injection is used to treat and prevent certain infections caused by bacteria. Penicillin G injection is in a class of medications called penicillins. It works by killing bacteria that cause infections. ...

  18. Amphotericin B Lipid Complex Injection

    Science.gov (United States)

    Amphotericin B lipid complex injection is used to treat serious, possibly life-threatening fungal infections in people who did ... respond or are unable to tolerate conventional amphotericin B therapy. Amphotericin B lipid complex injection is in ...

  19. Hydrazinonicotinamide prolongs quantum dot circulation and reduces reticuloendothelial system clearance by suppressing opsonization and phagocyte engulfment

    Science.gov (United States)

    Jung, Kyung-Ho; Park, Jin Won; Paik, Jin-Young; Lee, Eun Jeong; Choe, Yearn Seong; Lee, Kyung-Han

    2012-12-01

    In this study, we investigated the effects of hydrazinonicotinamide (HYNIC)—a bifunctional crosslinker widely used to 99mTc radiolabel protein and nanoparticles for imaging studies—on quantum dot opsonization, macrophage engulfment and in vivo kinetics. In streptavidin-coated quantum dots (SA-QDots), conjugation with HYNIC increased the net negative charge without affecting the zeta potential. Confocal microscopy and fluorescence-activated cell sorting showed HYNIC attachment to suppress SA-QDot engulfment by macrophages. Furthermore, HYNIC conjugation suppressed surface opsonization by serum protein including IgG. When intravenously injected into mice, HYNIC conjugation significantly prolonged the circulation of SA-QDots and reduced their hepatosplenic uptake. Diminished reticuloendothelial system clearance of SA-QDots and aminoPEG-QDots by HYNIC conjugation was also demonstrated by in vivo and ex vivo optical imaging. The effects of HYNIC on the opsonization, phagocytosis and in vivo kinetics of quantum dots were reversed by removal of the hydrazine component from HYNIC. Thus, surface functionalization with HYNIC can improve the in vivo kinetics of quantum dots by reducing phagocytosis via suppression of surface opsonization.

  20. Neutral tissue uptake and clearance of iohexol following lumbar myelography in rabbits

    International Nuclear Information System (INIS)

    Ekholm, S.E.; Foley, M.; Morris, T.W.; Sahler, L.

    1985-01-01

    The diffusion of water-soluble contrast media (CM) into the extracellular space of the central nervous system following injection into the subarachnoid space has previously been shown. As a result of this, water-soluble CM will come in direct contact with the neurons and may interfere with their normal function. The toxic effects would thus be a result both of the molecular properties of the CM as well as the local tissue concentration. The neuronal tissue uptake and clearance of metrizamide in rabbits following lumbar myelography was described in a previous study by our group. This study indicated some retention of metrizamide in the spinal cord probably as a result of binding of the CM to the cell membrane. The mechanism for this has not yet been shown although it may relate to the binding of metrizamide via its 2-deoxy-D-glucose (2-DG) portion and the specific glucose membrane carrier. The present investigation was performed to evaluate the diffusion kinetics of a new non-ionic CM. With iohexol, which lacks a 2-DG component in its molecule a direct relationship between the neural tissue and CSF concentration was found which seems to follow a simple diffusion model. Since iohexol shows no sign of entrapment in the tissue, the contact time for neurons will be shorter than that seen with metrizamide assuming that their rate of drainage from the SCF is identical. (orig.)