  1. Questionnaire survey on factors influencing comfort with indoor environmental quality in Danish housing

    DEFF Research Database (Denmark)

    Frontczak, Monika Joanna; Andersen, Rune Vinther; Wargocki, Pawel

    2012-01-01

    . A total of 2499 questionnaires were sent to inhabitants of the most common types of housing in Denmark; 645 persons replied (response rate of 26%). The results show that the main indoor environmental parameters (visual, acoustic and thermal conditions, and air quality) are considered by occupants......A questionnaire survey in Danish homes investigated the factors that influence occupants’ comfort. The questionnaire contained questions on inhabitants’ behaviour, their knowledge as regards building systems designed for controlling the indoor environment and the ways in which they achieve comfort...

  2. Indoor environmental risk factors in young asthmatics: a case-control study.

    Science.gov (United States)

    Lindfors, A; Wickman, M; Hedlin, G; Pershagen, G; Rietz, H; Nordvall, S L

    1995-11-01

    One hundred and ninety three children with asthma and 318 controls aged 1-4 years were evaluated for atopic heredity and exposure to possible indoor risk factors for asthma-for example exposure to furred pets, tobacco smoke, and home dampness. A subgroup of cases were classified as cat and/or dog allergic on the basis of skin prick tests. Heredity for asthma was a significant risk factor (odds ratio (OR) 3.0, confidence interval (CI) 2.1 to 4.6). Environmental tobacco smoke was associated with an excess risk for asthma (OR 1.7, CI 1.1 to 2.3) and signs of home dampness tended to increase this risk (OR 1.3, CI 0.9 to 2.0). High dose exposure to cat and/or dog resulted in an increased risk only in asthma cases sensitised to cat and/or dog (OR 2.7, CI 1.0 to 7.3). A combination of high dose exposure to cat and/or dog, environmental tobacco smoke and damp housing was associated with an OR of 8.0 (CI 1.9 to 34.1). Raised indoor humidity has been shown to reflect low air exchange, which may also lead to increased doses of inhaled aeroallergens and tobacco smoke, and contribute to the interaction between the three risk factors.

  3. Indoor Environmental Factors and Occurrence of Lung Function Decline in Adult Residents in Summer in Southwest China.

    Science.gov (United States)

    Jie, Yu; Kebin, Li; Yin, Tang; Jie, Xu

    2016-11-01

    There is conflicting reports on the respiratory health effects of indoor risk factor exposure. The aim of this study was to assess the association of indoor environmental factors to pulmonary function in an adult population in Zunyi City of Southwest China. Between July and Sep 2012, we conducted a cross-sectional survey of people aged ≥18 yr in 11 inner-city areas of Zunyi. Data on asthma and asthma-related symptoms and selected home environmental factors were assessed by questionnaire. Lung function measurements, including FVC, FEV 1 , FEV 1 /FVC and PEFR, were assessed and compared. Exposure to indoor and outdoor PM 2.5 was monitored by measurement of PM 2.5 emission relative concentration. Cooking oil fumes, environmental tobacco smoke (ETS) and coal fuel use were associated with impaired lung function among adults in summer season ( P oil fumes, pest in kitchen, mosquito repellent, fluffy blanket, pets, visible mold in bedroom and ETS (active and passive smoking) tended to exhibit greater decreases in FVC, FEV 1 and PEFR values compared with their non-exposed counterparts ( P kitchen, sleeping area and outdoor were 486.0cpm, 463.0cpm and 459.0cpm, respectively. PM 2.5 relative concentration in indoor kitchen and sleeping area were significant higher than outdoor ( P kitchen, sleeping area risk factors and ETS exposure and a reduction in lung function in summer was revealed in Zunyi.

  4. Environmental assessments on schools located on or near former industrial facilities: Feedback on attenuation factors for the prediction of indoor air quality.

    Science.gov (United States)

    Derycke, Virginie; Coftier, Aline; Zornig, Clément; Léprond, Hubert; Scamps, Mathilde; Gilbert, Dominique

    2018-06-01

    One of the goals of the French national campaign called "Etablissements Sensibles (Sensitive Establishments)" is to evaluate indoor air degradation in schools because of vapor intrusion of volatile compounds from soil gases towards the indoor air, related to the presence of former industrial sites on or near the establishment. During this campaign, as recommended by the United States of Environmental Protection Agency (US EPA), indoor air quality was evaluated from soil gas concentrations using generic attenuation factors, and extra investigations into soil gases and indoor air were performed when the estimated values exceeded target indoor air concentrations. This study exploits matched data on subsurface soil gases and indoor air that came from the "Sensitive Establishments" campaign. It aims to consolidate and refine the use of attenuation factors as a function of environmental variables acquired routinely during environmental assessments. We have been able to select the measured environmental variables that have the most influence on vapor intrusion using Principal Components Analysis and hypotheses tests. Since the collected data are mainly related to weak sources (only 15% schools required risk management measures related to vapor intrusion), halogenated volatile organic compounds (HVOC) were selected as tracer compounds for vapor intrusion for this study. This choice enables the exclusion or minimization of background sources contributions. From the results we have calculated the descriptive statistics of the attenuation factors distribution for the subslab-to-indoor air pathway and refined the attenuation factors for this pathway through an easily obtained parameter, building age. Qualitative comparison of attenuation factors according to the building age shows that attenuation factors observed for building less than 50 years are lower than attenuation factors for buildings 50 years old and above. These results show the utility of creating databases for

  5. Indoor environmental factors associated with pulmonary function among adults in an acid rain-plagued city in Southwest China.

    Science.gov (United States)

    Yu, Jie; Zhang, Longju; Luo, Ya; Tang, Yin; Tuo, Fangxu; Yang, Jiaqi; Xu, Jie

    2017-04-01

    To assess the association of indoor environmental risk factors with respiratory function among adults in an acid rain-plagued city in China where coal use is frequent. The subjects were randomly selected in the winter season. Information on selected home environmental factors was collected through administered questionnaires. Additionally, pulmonary function tests, including Forced Vital Capacity (FVC), Forced Expiratory Volume in 1 s (FEV 1 ), FEV 1 /FVC and Peak Expiratory Flow Rate (PEFR) were also performed in participants. This study showed that, among a variety of risk factors, coal fuel use, cooking oil fumes and active and passive smoking exposure together with asthma in childhood were important factors for deterioration of pulmonary function among adults in the winter season (p kitchen was located in the living room or bedroom, who opened their windows only occasionally or never, who noted the presence of cooking oil fumes and pests, whose bedroom was shared by 3 or more residents and who kept pets tended to exhibit lower values of FVC, FEV 1 and PEFR values compared with non-exposed counterparts (p < 0.05). This study demonstrated impaired pulmonary function among adults who were exposed to indoor risk factors, such as coal fires and cigarette smoking compared to non-users in the winter season and emphasizes the need for public health efforts to decrease exposure to indoor air pollution.

  6. Indoor air quality environmental information handbook: Combustion sources

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    This environmental information handbook was prepared to assist both the non-technical reader (i.e., homeowner) and technical persons (such as researchers, policy analysts, and builders/designers) in understanding the current state of knowledge regarding combustion sources of indoor air pollution. Quantitative and descriptive data addressing the emissions, indoor concentrations, factors influencing indoor concentrations, and health effects of combustion-generated pollutants are provided. In addition, a review of the models, controls, and standards applicable to indoor air pollution from combustion sources is presented. The emphasis is on the residential environment. The data presented here have been compiled from government and privately-funded research results, conference proceedings, technical journals, and recent publications. It is intended to provide the technical reader with a comprehensive overview and reference source on the major indoor air quality aspects relating to indoor combustion activities, including tobacco smoking. In addition, techniques for determining potential concentrations of pollutants in residential settings are presented. This is an update of a 1985 study documenting the state of knowledge of combustion-generated pollutants in the indoor environment. 191 refs., 51 figs., 71 tabs.

  7. Indoor Air Pollution (Environmental Health Student Portal)

    Science.gov (United States)

    ... Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ... Pollution Indoor Air Pollution Print this Page Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ...

  8. Indoor environmental health

    CSIR Research Space (South Africa)

    Parsons, S

    2010-01-01

    Full Text Available Indoor Environmental Health (IEH) is a comprehensive term that includes the effects of quantity of air, light and noise in a space and the physical, physiological and psychological aspects from colours, aesthetics, services, outdoor climate...

  9. Indoor environmental health

    CSIR Research Space (South Africa)

    Parsons, SA

    2010-04-01

    Full Text Available Indoor Environmental Health (IEH) is a comprehensive term that includes the effects of quantity of air, light and noise in a space and the physical, physiological and psychological aspects from colours, aesthetics, services, outdoor climate...

  10. Influence of environmental factors on indoor radon concentration levels in the basement and ground floor of a building – A case study

    International Nuclear Information System (INIS)

    Xie, Dong; Liao, Maili; Kearfott, Kimberlee J.

    2015-01-01

    A series of experiments was conducted to measure indoor radon concentrations variations and observe any correlations with indoor and outdoor atmospheric parameters for over a period of one year. Indoor environmental parameters and radon concentrations were measured on an hourly basis in a two-story building both in a laboratory on the well-ventilated ground floor and in the basement below it which had negligible ventilation. The monthly average indoor radon concentration value of 29 ± 21 Bq m"−"3 in the laboratory was below the ICRP recommended limit of 200–300 Bq m"−"3. The monthly normalization factor for that location ranged from 0.5 to 2.0, while the seasonal normalization factor ranged from 0.78 to 2.0. In the unventilated basement, however, the average monthly indoor radon concentration was 1083 ± 6 Bq m"−"3 with little seasonal variation. The basement is only used for storage and thus the elevated radon concentration does not pose a serious health risk. The results indicated that indoor radon levels are higher in the autumn–winter season than in the spring–summer season. Analysis further showed that indoor radon concentrations negatively correlated with indoor humidity (correlation coefficient R = −0.14, p < 0.01), outdoor temperature (correlation coefficient R = −0.3, p < 0.01), outdoor dew point temperature (correlation coefficient R = −0.17, p < 0.01) and outdoor wind speeds (correlation coefficient R = −0.25, p < 0.05). Radon concentrations correlated positively with outdoor barometric pressure (correlation coefficient R = 0.35, p < 0.01), indoor–outdoor temperature difference (correlation coefficient R = 0.32, p < 0.05) and indoor–outdoor barometric pressure difference (correlation coefficient R = 0.67, p < 0.01). Indoor temperature, indoor barometric pressure and outdoor wind direction showed no clear correlations with indoor radon concentration. - Highlights: • Environmental variables and

  11. Literature survey on how different factors influence human comfort in indoor environments

    DEFF Research Database (Denmark)

    Frontczak, Monika Joanna; Wargocki, Pawel

    2011-01-01

    examined the extent to which other factors unrelated to the indoor environment, such as individual characteristics of building occupants, building-related factors and outdoor climate including seasonal changes, influence whether the indoor environment is evaluated as comfortable or not. The results suggest...... environmental conditions influencing comfort in the built environment were surveyed: thermal, visual and acoustic, as well as air quality. The literature was surveyed to determine which of these conditions were ranked by building users as being the most important determinants of comfort. The survey also...... quality. Thermal comfort is ranked by building occupants to be of greater importance compared with visual and acoustic comfort and good air quality. It also seems to influence to a higher degree the overall satisfaction with indoor environmental quality compared with the impact of other indoor...

  12. Environmental burdens of a Finnish indoor swimming pool; Uimahallin ympaeristoekuormitukset

    Energy Technology Data Exchange (ETDEWEB)

    Vaahterus, T.; Saari, A.

    2001-07-01

    In this study the environmental burdens of a Finnish indoor swimming pool generated by its energy consumption were calculated. The calculations were made by using a calculation method based on LCA methodology. Calculations were made of 50 years period. The energy consumption dating from the time of the indoor swimming pool causes towards the gross-floor area a nearly four times bigger environmental load than for example a block of flats and indoor ice- skating rink. On a block of flats and indoor ice-skating rink the energy consumption dating from the time of the use causes more than 90 % of the environmental burdens of the whole life span. One can suppose that at the indoor swimming pool the share of the energy consumption dating from the time of the use only is emphasized. In this study confine therefore to dealing with the environmental loads caused only by the energy consumption dating from the time of the use. The results of these calculations showed that the energy flow of the life cycle energy consumption was 193 000 MJ/brm{sup 2}. 11,2 ton per gross-floor area CO{sub 2} equivalents, 21 kg per gross-floor area SO{sub 2} equivalents and 290 g per gross-floor area ethene equivalents of environmental burdens were caused. The main factor causing the most environmental loads were the need of heating energy. The need of heating energy produced 75 % of the CO{sub 2} equivalents, 70 % of the SO{sub 2} equivalents and 59 % of the ethene equivalents. The need of the electric energy produced 23 % of the CO{sub 2} equivalents, 23 % of the SO{sub 2} equivalents and 17 % of the ethene equivalents. Of the heating energy the share of the warming of water was 56 %. The most significant part of the electric energy were consumed in the use of the sauna stoves and vapor sauna (31 %) and heating pumps and water elements (30 %). Almost all (87 %) of the energy, consumed during the life cycle, was produced with non-renewable energy sources. The source information of the energy was

  13. BRIDGING OUTDOOR AND INDOOR ENVIRONMENTAL SIMULATION FOR ASSESSING AND AIDING SUSTAINABLE URBAN NEIGHBOURHOOD DESIGN

    Directory of Open Access Journals (Sweden)

    Chengzhi Peng

    2012-11-01

    Full Text Available Urban dwellers in cities located in hot-arid or hothumid regions have greater needs to live in between outdoor and indoor environments. The sustainability of urban building design in these regions cannot be fully assessed by indoor environmental simulation not taking into account the microclimatic factors of the surrounding urban neighbourhood. We find that the current suites of outdoor and indoor simulation software do not connect with each other to give us a holistic understanding of both outdoor and indoor simulation results. This paper reports on our current development of a methodological framework for bridging the current gap between outdoor and indoor environmental simulation. Our objective is that assessment of sustainability at an urban neighbourhood level can be carried out more holistically, and hence achieving more valid environmental simulations from an urban  dwelling point of view. The outdoor-indoor coupling methodology is currently modelled on a digital work flow among three key software platforms: (1 ENVImet for urban neighbourhood outdoor simulation, (2 Ecotect for building indoor simulation, (3 uCampus for combined outdoor-indoor 3D visualisation modelling of an entire urban neighbourhood including its individual buildings. A case study of a new neighbourhood development proposed for New Cairo is presented to demonstrate how indoor environmental simulation can be grounded on outdoor environmental simulation of the urban neighbourhood. Graphical outputs from this outdoorindoor coupling approach to neighbourhood simulation can be further brought together onto a Web-based 3D virtual reality modelling platform to enable wider accessibility.

  14. Indoor microclimate in a South African school: impact of indoor environmental factors

    CSIR Research Space (South Africa)

    Essah, EA

    2016-07-01

    Full Text Available Demand for good indoor air quality is increasing as people recorgnise the risks to their health and productivity from indoor pollutants. There is a tendency to reduce ventilation rates to ensure energy conservation in buildings; in this instance...

  15. Indoor inhalation intake fractions of fine particulate matter: Review of influencing factors

    DEFF Research Database (Denmark)

    Hodas, Natasha; Loh, Miranda; Shin, Hyeong-Moo

    2016-01-01

    Exposure to fine particulate matter (PM2.5) is a major contributor to the global human disease burden. The indoor environment is of particular importance when considering the health effects associated with PM2.5 exposures because people spend the majority of their time indoors and PM2.5 exposures...... per unit mass emitted indoors are two to three orders of magnitude larger than exposures to outdoor emissions. Variability in indoor PM2.5 intake fraction (iFin,total), which is defined as the integrated cumulative intake of PM2.5 per unit of emission, is driven by a combination of building......-specific, human-specific, and pollutant-specific factors. Due to a limited availability of data characterizing these factors, however, indoor emissions and intake of PM2.5 are not commonly considered when evaluating the environmental performance of product life cycles. With the aim of addressing this barrier...

  16. Reflections on the State of Research: Indoor Environmental Quality

    DEFF Research Database (Denmark)

    Clausen, Geo; Bekö, Gabriel; Corsi, Richard

    2011-01-01

    that with parallel research and writing efforts culminating with internal review and revision cycles. In this paper, we present our choices for the most important research findings on indoor environmental quality from the past three decades followed by a discussion of the most important research questions in our......More than 30 years after the First International Indoor Climate Symposium, ten researchers from the USA, Slovakia, Sweden, and Denmark gathered to review the current status of indoor environmental research. We initiated our review with discussions during the 1-day meeting and followed...

  17. Providing better indoor environmental quality brings economicbenefits

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William; Seppanen, Olli

    2007-06-01

    This paper summarizes the current scientific evidence that improved indoor environmental quality can improve work performance and health. The review indicates that work and school work performance is affected by indoor temperature and ventilation rate. Pollutant source removal can sometimes improve work performance. Based on formal statistical analyses of existing research results, quantitative relationships are provided for the linkages of work performance with indoor temperature and outdoor air ventilation rate. The review also indicates that improved health and related financial savings are obtainable from reduced indoor tobacco smoking, prevention and remediation of building dampness, and increased ventilation. Example cost-benefit analyses indicate that many measures to improve indoor temperature control and increase ventilation rates will be highly cost effective, with benefit-cost ratios as high as 80 and annual economic benefits as high as $700 per person.

  18. Environmental Loads of a Finnish indoor training iceskating rink in the Context of LCA

    International Nuclear Information System (INIS)

    Vaahterus, T.; Saari, A.

    2001-01-01

    34 %. In that usage profile the indoor training ice skating rink were used for many ice hockey matches. A five-degree (+/-) change in the indoor temperature of the indoor training ice skating rink changed the total amount of environmental emissions by 30 (+/-). In addition to these condensate heat recovery had a major influence on the environmental emissions. A lack of condensate heat recovery increased the environmental loads of the indoor training ice skating rink almost 30 %. Other presumptions to which the calculations were relatively sensitive were the location of rink in Finland, the emissivity of cover, the ice temperature, and the type of fuel used to produce the heating energy of the rink. Changes in all these factors had at least a 10 effect on the result of the calculations. (orig.)

  19. A holistic approach to improving indoor environmental quality: A case study

    International Nuclear Information System (INIS)

    Milam, J.A.; Kinser, D.E.

    1993-01-01

    One of the big six accounting firms recently consolidated several offices into a regional headquarters located in a southern metropolitan city. This regional headquarters involved seven floors totalling 187,000 square feet of tenant space in a new high rise building. The accounting firm realized that improving their employees' work environment would provide significant savings from increased worker productivity and reduced absenteeism. Therefore, the firm retained Environmental Design International (EDI) to provide consulting services to create and maintain an environmentally healthy office space. The creation of a healthy, productive and safe indoor environment involves a total, holistic approach to the various elements that affect indoor environmental quality (IEQ) in a building. A holistic approach requires detailed evaluation of all areas that impact indoor environmental quality and not just the more common review of HVAC systems. This case study shows that the optimization of a healthy indoor environment is an endless, all inclusive process: beginning with the initial construction material selections and environmental systems design; continuing through the construction and commissioning phases; and progressing to pro-active monitoring of IEQ parameters to protect the tenant's investment in a healthy, productive and safe indoor environment

  20. Urbanization Reduces Transfer of Diverse Environmental Microbiota Indoors

    Directory of Open Access Journals (Sweden)

    Anirudra Parajuli

    2018-02-01

    Full Text Available Expanding urbanization is a major factor behind rapidly declining biodiversity. It has been proposed that in urbanized societies, the rarity of contact with diverse environmental microbiota negatively impacts immune function and ultimately increases the risk for allergies and other immune-mediated disorders. Surprisingly, the basic assumption that urbanization reduces exposure to environmental microbiota and its transfer indoors has rarely been examined. We investigated if the land use type around Finnish homes affects the diversity, richness, and abundance of bacterial communities indoors. Debris deposited on standardized doormats was collected in 30 rural and 26 urban households in and near the city of Lahti, Finland, in August 2015. Debris was weighed, bacterial community composition determined by high throughput sequencing of bacterial 16S ribosomal RNA (rRNA gene on the Illumina MiSeq platform, and the percentage of four different land use types (i.e., built area, forest, transitional, and open area within 200 m and 2000 m radiuses from each household was characterized. The quantity of doormat debris was inversely correlated with coverage of built area. The diversity of total bacterial, Proteobacterial, Actinobacterial, Bacteroidetes, and Firmicutes communities decreased as the percentage of built area increased. Their richness followed the same pattern except for Firmicutes for which no association was observed. The relative abundance of Proteobacteria and particularly Gammaproteobacteria increased, whereas that of Actinobacteria decreased with increasing built area. Neither Phylum Firmicutes nor Bacteroidetes varied with coverage of built area. Additionally, the relative abundance of potentially pathogenic bacterial families and genera increased as the percentage of built area increased. Interestingly, having domestic animals (including pets only altered the association between the richness of Gammaproteobacteria and diversity of

  1. Air Quality and Indoor Environmental Exposures: Clinical ...

    Science.gov (United States)

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more polluted than ambient air, the USEPA lists poor IAQ as a major environmental concern. In the sections that follow, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. In some cases, exposure may be acute, with one or more pets (and owners) experiencing signs within a relatively short period. However, most exposures are episodic or chronic, making it difficult to definitively link poor IAQ to respiratory or other adverse health outcomes. Age or underlying immunologic, cardiac, or respiratory disease may further complicate the clinical picture, as those patients may be more sensitive to (and affected by) lower concentrations than prove problematic for healthy housemates. Because pets, like their owners, spend most of their lives indoors, we will discuss how certain home conditions can worsen indoor air quality and will briefly discuss measures to improve IAQ for owners and their pets. In this overview presentation, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. Because pets, like their owners, spend most of their lives indoo

  2. Risk factors for severe injury following indoor and outdoor falls in geriatric patients.

    Science.gov (United States)

    Kim, Sun Hyu

    2016-01-01

    This study was performed to examine the characteristics of indoor and outdoor falls in older patients and the factors related to severe injury in the emergency department (ED). In total, 26,515 patients fell indoors and 19,581 outdoors. The general and clinical characteristics were compared between the two groups and factors associated with severe injury following the falls were evaluated. Younger males fell more frequently outdoors than indoors. The common activities during outdoor falls were sports and leisure activities. Environmental hazards lead to more outdoor falls than indoor falls. Factors associated with severe injury after indoor falls were transport to the ED by public ambulance or from another medical facility rather than individual transportation, fall from stairs rather than fell over, and a head and neck injury rather than a lower extremity injury. Factors related to severe injury after outdoor falls were male sex, transport to the ED by public ambulance or from another medical facility or by another method rather than individual transportation, state employed, fall from stairs rather than fell over, head and neck or thorax or abdomen injury rather than a lower extremity injury. Transport to the ED by public ambulance or from another medical facility, and head and neck injury were risks for severe injury following indoor and outdoor falls in elderly subjects. Efforts to identify the risk factors for severe injury and for falling itself are important to prevent and reduce fall injuries in elderly subjects. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Performance Indicators of Indoor Environmental Quality (IEQ ...

    African Journals Online (AJOL)

    Sultan

    environmental framework for the promotion of a healthy and comfortable ... (n.d.) consists of six metrics namely: Indoor air quality (IAQ) ..... Quality. Thermal quality measurement in the hospital ...... article/pii/S036013231300142X. Jensen, K.

  4. Efficiency assessment of indoor environmental policy for air-conditioned offices in Hong Kong

    International Nuclear Information System (INIS)

    Wong, L.T.; Mui, K.W.

    2009-01-01

    To reduce carbon dioxide (CO 2 ) emissions through thermal energy conservation, air-conditioned offices in the subtropics are recommended to operate within specified ranges of indoor temperature, relative humidity and air velocity. As thermal discomfort leads to productivity loss, some indoor environmental policies for air-conditioned offices in Hong Kong are investigated in this study with relation to thermal energy consumption, CO 2 emissions from electricity use, and productivity loss due to thermal discomfort. Occupant thermal response is specifically considered as an adaptive factor in evaluating the energy consumption and productivity loss. The energy efficiency of an office is determined by the productivity which corresponds to the CO 2 generated. The results found that a policy with little impact on occupant thermal comfort and worker productivity would improve the office efficiency while the one with excessive energy consumption reduction would result in a substantial productivity loss. This study is a useful reference source for evaluating an indoor thermal environmental policy regarding the energy consumption, CO 2 emissions reduction, thermal comfort and productivity loss in air-conditioned offices in subtropical areas.

  5. Environmental Loads of a Finnish indoor training iceskating rink in the Context of LCA; Jaeaehallirakennuksen aiheuttamat ympaeristoekuormitukset

    Energy Technology Data Exchange (ETDEWEB)

    Vaahterus, T.; Saari, A.

    2001-07-01

    skating rink 34 %. In that usage profile the indoor training ice skating rink were used for many ice hockey matches. A five-degree (+/-) change in the indoor temperature of the indoor training ice skating rink changed the total amount of environmental emissions by 30 (+/-). In addition to these condensate heat recovery had a major influence on the environmental emissions. A lack of condensate heat recovery increased the environmental loads of the indoor training ice skating rink almost 30 %. Other presumptions to which the calculations were relatively sensitive were the location of rink in Finland, the emissivity of cover, the ice temperature, and the type of fuel used to produce the heating energy of the rink. Changes in all these factors had at least a 10 effect on the result of the calculations. (orig.)

  6. Indoor risk factors for cough and their relation to wheeze and sensitization in Chilean young adults.

    Science.gov (United States)

    Potts, James F; Rona, Roberto J; Oyarzun, Manuel J; Amigo, Hugo; Bustos, Patricia

    2008-04-01

    We assessed the effects of indoor risk factors, including smoking, on different types of cough and on cough and wheeze in combination. Our sample was composed of 1232 men and women residing in a semirural area of Chile. We used a standardized questionnaire, sensitization to 8 allergens, and bronchial hyperresponsiveness to methacholine to assess cough and wheeze characteristics. Information was gathered on dampness, mold, ventilation, heating, housing quality, smoking, and environmental tobacco smoke exposure. Most exposures were associated with cough alone or cough in combination with wheeze. Smoking, past smoking, and environmental tobacco smoke exposure were strongly associated with dry cough and wheeze. The use of coal for heating was associated with dry cough. Leaks, mold, and lack of kitchen ventilation were associated with cough and wheeze. Nocturnal cough and productive cough were associated with specific types of sensitization, but dry cough was not. Productive cough was associated with hyperresponsiveness to methacholine. Several different types of indoor exposures, including environmental tobacco smoke exposure, are important contributors to morbidity associated with cough and wheeze. A vigorous preventive strategy designed to lower exposures to indoor risk factors would lower rates of respiratory morbidity.

  7. Indoor risk factors for cough and their relation to wheeze and sensitization in Chilean young adults

    Energy Technology Data Exchange (ETDEWEB)

    Potts, J.F.; Rona, R.J.; Oyarzun, M.J.; Amigo, H.; Bustos, P. [Kings College London, London (United Kingdom). Dept. for Public Health Science

    2008-04-15

    We assessed the effects of indoor risk factors, including smoking, on different types of cough and on cough and wheeze in combination. Our sample was composed of 1232 men and women residing in a semi-rural area of Chile. We used a standardized questionnaire, sensitization to 8 allergens, and bronchial hyperresponsiveness to methacholine to assess cough and wheeze characteristics. Information was gathered on dampness, mold, ventilation, heating, housing quality, smoking, and environmental tobacco smoke exposure. Most exposures were associated with cough alone or cough in combination with wheeze. Smoking, past smoking, and environmental tobacco smoke exposure were strongly associated with dry cough and wheeze. The use of coal for heating was associated with dry cough. Leaks, mold, and lack of kitchen ventilation were associated with cough and wheeze. Nocturnal cough and productive cough were associated with specific types of sensitization, but dry cough was not. Productive cough was associated with hyperresponsiveness to methacholine. Several different types of indoor exposures, including environmental tobacco smoke exposure, are important contributors to morbidity associated with cough and wheeze. A vigorous preventive strategy designed to lower exposures to indoor risk factors would lower rates of respiratory morbidity.

  8. Indoor Risk Factors for Cough and Their Relation to Wheeze and Sensitization in Chilean Young Adults

    Science.gov (United States)

    Potts, James F.; Rona, Roberto J.; Oyarzun, Manuel J.; Amigo, Hugo; Bustos, Patricia

    2008-01-01

    Objectives. We assessed the effects of indoor risk factors, including smoking, on different types of cough and on cough and wheeze in combination. Methods. Our sample was composed of 1232 men and women residing in a semirural area of Chile. We used a standardized questionnaire, sensitization to 8 allergens, and bronchial hyperresponsiveness to methacholine to assess cough and wheeze characteristics. Information was gathered on dampness, mold, ventilation, heating, housing quality, smoking, and environmental tobacco smoke exposure. Results. Most exposures were associated with cough alone or cough in combination with wheeze. Smoking, past smoking, and environmental tobacco smoke exposure were strongly associated with dry cough and wheeze. The use of coal for heating was associated with dry cough. Leaks, mold, and lack of kitchen ventilation were associated with cough and wheeze. Nocturnal cough and productive cough were associated with specific types of sensitization, but dry cough was not. Productive cough was associated with hyperresponsiveness to methacholine. Conclusions. Several different types of indoor exposures, including environmental tobacco smoke exposure, are important contributors to morbidity associated with cough and wheeze. A vigorous preventive strategy designed to lower exposures to indoor risk factors would lower rates of respiratory morbidity. PMID:17666696

  9. Estimation of sources and factors affecting indoor VOC levels using basic numerical methods

    Directory of Open Access Journals (Sweden)

    Sibel Mentese

    2016-11-01

    Full Text Available Volatile Organic Compounds (VOCs are a concern due to their adverse health effects and extensive usage. Levels of indoor VOCs were measured in six homes located in three different towns in Çanakkale, Turkey. Monthly indoor VOC samples were collected by passive sampling throughout a year. The highest levels of total volatile organic compounds (TVOC, benzene, toluene, and xylenes occurred in industrial, rural, and urban sites in a descending order. VOC levels were categorized as average values annually, during the heating period, and non-heating period. Several building/environmental factors together with occupants’ habits were scored to obtain a basic indoor air pollution index (IAPi for the homes. Bivariate regression analysis was applied to find the associations between the pollutant levels and home scores. IAPi scores were found to be correlated with average indoor VOC levels. In particular, very strong associations were found for occupants’ habits. Furthermore, observed indoor VOC levels were categorized by using self-organizing map (SOM and two simple scoring approaches, rounded average and maximum value methods, to classify the indoor environments based on their VOC compositions (IAPvoc. Three classes were used for both IAPi and IAPvoc approaches, namely “good”, “moderate”, and “bad”. There is an urgent need for indexing studies to determine the potential sources and/or factors affecting observed VOCs. This study gives a basic but good start for further studies.

  10. Comfort Indicators for the Assessment of Indoor Environmental Building Performance

    DEFF Research Database (Denmark)

    Brohus, Henrik; Bendtsen, A.; Sørensen, M.

    2006-01-01

    Indoor environmental building performance assessment requires efficient indicators of the indoor comfort. In order to be effective and useful the comfort indicators must be able to include the temporal variation of indoor comfort as well as the degree of discomfort perceived by the occupants....... This paper discusses and presents a number of comfort indicators that includes both the temporal variation and the degree of discomfort in the calculations. A test case comprising a ventilated office building is used to show the application of the various comfort indices. It is found that the new comfort...

  11. Individual and environmental risk factors for high blood lead concentrations in Danish indoor shooters.

    Science.gov (United States)

    Grandahl, Kasper; Suadicani, Poul; Jacobsen, Peter

    2012-08-01

    International studies have shown blood lead at levels causing health concern in recreational indoor shooters. We hypothesized that Danish recreational indoor shooters would also have a high level of blood lead, and that this could be explained by shooting characteristics and the physical environment at the shooting range. This was an environmental case study of 58 male and female shooters from two indoor shooting ranges with assumed different ventilation and cleaning conditions. Information was obtained on general conditions including age, gender, tobacco and alcohol use, and shooting conditions: weapon type, number of shots fired, frequency of stays at the shooting range and hygiene habits. A venous blood sample was drawn to determine blood lead concentrations; 14 non-shooters were included as controls. Almost 60% of the shooters, hereof five out of 14 women, had a blood lead concentration above 0.48 micromol/l, a level causing long-term health concern. All controls had blood lead values below 0.17 micromol/l. Independent significant associations with blood lead concentrations above 0.48 micromol/l were found for shooting at a poorly ventilated range, use of heavy calibre weapons, number of shots and frequency of stays at the shooting range. A large proportion of Danish recreational indoor shooters had potentially harmful blood lead concentrations. Ventilation, amounts of shooting, use of heavy calibre weapons and stays at the shooting ranges were independently associated with increased blood lead. The technical check at the two ranges was performed by the Danish Technological Institute and costs were defrayed by the Danish Rifle Association. To pay for the analyses of blood lead, the study was supported by the The Else & Mogens Wedell-Wedellsborg Foundation. The Danish Regional Capital Scientific Ethics Committee approved the study, protocol number H-4-2010-130.

  12. Environmental burden of acute respiratory infection and pneumonia due to indoor smoke in Dhading.

    Science.gov (United States)

    Dhimal, M; Dhakal, P; Shrestha, N; Baral, K; Maskey, M

    2010-04-01

    ARI and pneumonia is one of the major public health problems in Nepal which always ranks highest position among the top ten diseases. One of the risk factor of ARI and pneumonia is indoor smoke from kitchen where primary source of cooking is solid biomass fuel. This study was carried out in order to estimate the burden of ARI and pneumonia due to indoor smoke. ARI and pneumonia was chosen as it is one of the significant public health problem among under five children in Nepal and responsible for high number of premature deaths. A cross-sectional study was conducted in Dhading district. Multistage cluster sampling technique was used for data collection considering ward as a cluster. The environmental burden of ARI and pneumonia due to indoor smoke was calculated using the WHO Environmental Burden of Disease Series. About 87 percent of households were using solid biomass fuel as a primary source of fuel. The under five children exposed to solid fuel use was 41313. The total 1284 Disability Adjusted Life Years were lost due to ARI and pneumonia and about 50 percent of it was attributed by Indoor smoke in household. The solid biomass fuel was primary source of energy for cooking in Dhading district which is attributing about 50 percent of burden of ARI and pneumonia among under five children.

  13. Indoor environmental quality in Hellenic hospital operating rooms

    Energy Technology Data Exchange (ETDEWEB)

    Dascalaki, Elena G.; Gaglia, Athina G.; Balaras, Constantinos A. [Group Energy Conservation, Institute for Environmental Research and Sustainable Development, National Observatory of Athens, I. Metaxa and Vas. Pavlou, GR 152 36 P. Penteli (Greece); Lagoudi, Argyro [Terra Nova Ltd., Environmental Engineering Consultancy, Athens, Kaisareias 39, GR 115 27 Athens (Greece)

    2009-05-15

    Indoor environmental quality (IEQ) in hospital operating rooms (ORs) constitutes a major challenge for the proper design and operation of an energy efficient hospital. A subjective assessment of the indoor environment along with a short monitoring campaign was performed during the audits of 18 ORs at nine major Hellenic hospitals. A total of 557 medical personnel participated in an occupational survey, providing data for a subjective assessment of IEQ in the audited ORs. The OR personnel reported work related health symptoms and an assessment of indoor conditions (thermal, visual and acoustical comfort, and air quality). Overall, personnel reported an average of 2.24 work-related symptoms each, and 67.2% of respondents reported at least one. Women suffer more health symptoms than men. Special dispositions, such as smoking and allergies, increase the number of reported symptoms for male and female personnel. Personnel that perceive satisfactory indoor comfort conditions (temperature, humidity, ventilation, light, and noise) average 1.18 symptoms per person, while for satisfactory indoor air quality the average complaints are 0.99. The perception of satisfactory IEQ (satisfactory comfort conditions and air quality) reduces the average number of health complaints to 0.64 symptoms per person and improves working conditions, even in a demanding OR environment. (author)

  14. Predictive control techniques for energy and indoor environmental quality management in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kolokotsa, D. [Technological Educational Institute of Crete, Department of Natural Resources and Environment, 3, Romanou str., 73133, Hania, Crete (Greece); Pouliezos, A. [Technical University of Crete, Department of Production Engineering and Management, University Campus, Kounoupidiana, 73100 Hania (Greece); Stavrakakis, G.; Lazos, C. [Technical University of Crete, Department of Electronics and Computer Engineering, University Campus, Kounoupidiana, 73100 Hania (Greece)

    2009-09-15

    The aim of the present paper is to present a model-based predictive controller, combined with a Building Energy Management System (BEMS). The overall system predicts the indoor environmental conditions of a specific building and selects the most appropriate actions so as to reach the set points and contribute to the indoor environmental quality by minimizing energy costs. The controller is tested using a BEMS installation in Hania, Crete, Greece. (author)

  15. [The comparison of the indoor environmental factors associated with asthma and related allergies among school-child between urban and suburban areas in Beijing].

    Science.gov (United States)

    Lü, Hai-bo; Deng, Fu-rong; Sun, Ji-dong; Wu, Shao-wei; Sun, Xiu-ming; Wang, Xin; Zhao, Yan-hua; Guo, Xin-biao

    2010-07-01

    To study the indoor environmental factors associated with the prevalence of asthma and related allergies among school children. A cluster sampling method was used and the ISAAC questionnaire was conducted. A total of 4612 elementary students under Grade Five of 7 schools were enrolled in the survey for the impact of indoor environmental factors on the prevalence of asthma and related allergies in several urban and suburban schools of Beijing. A total of 4060 sample were finally analyzed including 1992 urban and 2068 suburban. The prevalence of wheeze, allergic rhinoconjunctivitis and atopic eczema in the past 12 months was 3.1% (61/1992), 5.3% (106/1992), 1.1% (22/1992) among urban children while 1.3% (27/2068), 3.1% (65/2068), 1.0% (22/2068) among suburban children respectively. The prevalence of wheeze and allergic rhinoconjunctivitis of the past 12 months in urban were both significantly higher than that in suburban (χ(2) = 14.77, 11.93, P children (5.3% (105/1992), 29.4% (586/1992)) were significantly (χ(2) = 39.03, 147.22, P interior decoration had different influence on the prevalence of asthma and related allergies among school children in the two areas. The significant impact of passive smoking on having asthma ever among suburban children was observed (OR = 2.70, 95%CI = 1.17 - 6.23) while no significant result in urban (OR = 1.06, 95%CI = 0.71 - 1.58); the percentage of interior decoration was 84.0% (1673/1992) among urban children and 80.0% (1655/2068) among suburban children, there was significant impact of interior decoration on the prevalence of having eczema ever among urban children (OR = 1.57, 95%CI = 1.17 - 2.10) but no significant results were found in suburban sample (OR = 1.06, 95%CI = 0.76 - 1.48). The prevalence of asthma and related allergies among school children is much higher in urban areas than that in suburban areas and the indoor environmental factors such as passive smoking and interior decoration may differently explain the

  16. Design of environmentally friendly calcium sulfate-based building materials : towards an improved indoor air quality

    NARCIS (Netherlands)

    Yu, Q.

    2012-01-01

    This thesis addresses the performance based design and development of an environmentally friendly calcium sulfate-based indoor building product towards an improved indoor air quality. Here "environmental friendly" is referred to the environment related subjects including: (1) the selection of raw

  17. Factors influencing indoor concentrations of radon and daughter products

    International Nuclear Information System (INIS)

    Wang Hengde

    1985-01-01

    The correlation between indoor concentrations of 222 Rn and its daughters and some influencing factors is discussed and expressions of concentrations are derived with relation to radon exhalation rate from indoor surfaces, air exchange rate and daughter deposition velocities on indoor surfaces. Experimental methods for determining radon exhalation rate, air exchange rate and daughter deposition velocities are also mentioned

  18. Source Apportionment and Influencing Factor Analysis of Residential Indoor PM2.5 in Beijing

    Science.gov (United States)

    Yang, Yibing; Liu, Liu; Xu, Chunyu; Li, Na; Liu, Zhe; Wang, Qin; Xu, Dongqun

    2018-01-01

    In order to identify the sources of indoor PM2.5 and to check which factors influence the concentration of indoor PM2.5 and chemical elements, indoor concentrations of PM2.5 and its related elements in residential houses in Beijing were explored. Indoor and outdoor PM2.5 samples that were monitored continuously for one week were collected. Indoor and outdoor concentrations of PM2.5 and 15 elements (Al, As, Ca, Cd, Cu, Fe, K, Mg, Mn, Na, Pb, Se, Tl, V, Zn) were calculated and compared. The median indoor concentration of PM2.5 was 57.64 μg/m3. For elements in indoor PM2.5, Cd and As may be sensitive to indoor smoking, Zn, Ca and Al may be related to indoor sources other than smoking, Pb, V and Se may mainly come from outdoor. Five factors were extracted for indoor PM2.5 by factor analysis, explained 76.8% of total variance, outdoor sources contributed more than indoor sources. Multiple linear regression analysis for indoor PM2.5, Cd and Pb was performed. Indoor PM2.5 was influenced by factors including outdoor PM2.5, smoking during sampling, outdoor temperature and time of air conditioner use. Indoor Cd was affected by factors including smoking during sampling, outdoor Cd and building age. Indoor Pb concentration was associated with factors including outdoor Pb and time of window open per day, building age and RH. In conclusion, indoor PM2.5 mainly comes from outdoor sources, and the contributions of indoor sources also cannot be ignored. Factors associated indoor and outdoor air exchange can influence the concentrations of indoor PM2.5 and its constituents. PMID:29621164

  19. Design an Indoor Air Quality Controller Based on LPC2478

    Directory of Open Access Journals (Sweden)

    Shi Shuheng

    2014-07-01

    Full Text Available Indoor air quality is very important to our lives, because we spend most of our time indoor. In order to improve the air quality of indoor, this paper designs an indoor environment quality monitoring and controlling system based on ARM microcontroller LPC2478. It will do a real-time monitoring work for detecting the indoor environmental factors and comprehensively evaluate its air quality level. While the indoor air quality status is "poor", this intelligent system will automatically start the heat exchange ventilator for indoor environmental quality improvement. The results compared to traditional natural ventilation method show the better performance of proposed system.

  20. Risk factors for indoor air pollution in rural households in Mauche ...

    African Journals Online (AJOL)

    Risk factors for indoor air pollution in rural households in Mauche division, Molo ... indoor air pollution, which has been associated with various diseases. Key words: biomass fuel, children, indoor pollution, respiratory infections, ventilation.

  1. An investigation of factors influencing indoor radon concentrations

    International Nuclear Information System (INIS)

    Majborn, B.; Soerensen, A.; Nielsen, S.P.; Boetter-Jensen, L.

    1988-05-01

    Variations in indoor radon concentrations and some influencing factors have been studied during a two-year period (1986-1987) in 16 almost identical single-family houses.The annual average radon concentration in the houses varied from about 50 to about 400 Bq/m 3 . Variations in soil characteristics and radon concentration in soil gas could not be directly related to the variations of the average indoor radon concentrations. Most of the houses showed a ''normal'' seasonal variation of the radon concentration with a maximum in the winter and minimum in the summer. A deviating seasonal variation was found in three of the houses. Hourly data obtained in one unoccupied house during a period of 2-1/2 months showed no or only weak correlations between the indoor radon concentration and meteorological factors. However, for most of the houses, the seasonal variation of the indoor radon concentration was well correlated with the average indoor-outdoor temperature difference on a 2-month basis. It was demonstrated that the radon concentration can be strongly reduced in the Risoe houses if a district-heating duct, which is connected to all the houses, is ventilated, so that a slightly lowered pressure is maintained in the duct. 5 taps., 24 ill. (author)

  2. Indoor air - assessment: Methods of analysis for environmental carcinogens

    International Nuclear Information System (INIS)

    Peterson, M.R.; Naugle, D.F.; Berry, M.A.

    1990-06-01

    The monograph describes, in a general way, published sampling procedures and analytical approaches for known and suspected carcinogens. The primary focus is upon carcinogens found in indoor air, although the methods described are applicable to other media or environments. In cases where there are no published methods for a particular pollutant in indoor air, methods developed for the workplace and for ambient air are included since they should be adaptable to indoor air. Known and suspected carcinogens have been grouped into six categories for the purposes of this and related work. The categories are radon, asbestos, organic compounds, inorganic species, particles, and non-ionizing radiation. Some methods of assessing exposure that are not specific to any particular pollutant category are covered in a separate section. The report is the fifth in a series of EPA/Environmental Criteria and Assessment Office Monographs

  3. Indoor environmental quality in French dwellings and building characteristics

    Science.gov (United States)

    Langer, Sarka; Ramalho, Olivier; Derbez, Mickaël; Ribéron, Jacques; Kirchner, Severine; Mandin, Corinne

    2016-03-01

    A national survey on indoor environmental quality covering 567 residences in mainland France was performed during 2003-2005. The measured parameters were temperature, relative humidity, CO2, and the indoor air pollutants: fourteen individual volatile organic compounds (VOC), four aldehydes and particulate matter PM10 and PM2.5. The measured indoor concentrations were analyzed for correlations with the building characteristics: type of dwelling, period of construction, dwelling location, type of ventilation system, building material, attached garage and retrofitting. The median night time air exchange rate (AER) for all dwellings was 0.44 h-1. The night time AER was higher in apartments (median = 0.49 h-1) than in single-family houses (median = 0.41 h-1). Concentration of formaldehyde was approximately 30% higher in dwellings built after 1990 compared with older ones; it was higher in dwellings with mechanical ventilation and in concrete buildings. The VOC concentrations depended on the building characteristics to various extents. The sampling season influenced the majority of the indoor climate parameters and the concentrations of the air pollutants to a higher degree than the building characteristics. Multivariate linear regression models revealed that the indoor-outdoor difference in specific humidity, a proxy for number of occupants and their indoor activities, remained a significant predictor for most gaseous and particulate air pollutants. The other strong predictors were outdoor concentration, smoking, attached garage and AER (in descending order).

  4. Variance of indoor radon concentration: Major influencing factors

    Energy Technology Data Exchange (ETDEWEB)

    Yarmoshenko, I., E-mail: ivy@ecko.uran.ru [Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy, 20, Ekaterinburg (Russian Federation); Vasilyev, A.; Malinovsky, G. [Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy, 20, Ekaterinburg (Russian Federation); Bossew, P. [German Federal Office for Radiation Protection (BfS), Berlin (Germany); Žunić, Z.S. [Institute of Nuclear Sciences “Vinca”, University of Belgrade (Serbia); Onischenko, A.; Zhukovsky, M. [Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy, 20, Ekaterinburg (Russian Federation)

    2016-01-15

    Variance of radon concentration in dwelling atmosphere is analysed with regard to geogenic and anthropogenic influencing factors. Analysis includes review of 81 national and regional indoor radon surveys with varying sampling pattern, sample size and duration of measurements and detailed consideration of two regional surveys (Sverdlovsk oblast, Russia and Niška Banja, Serbia). The analysis of the geometric standard deviation revealed that main factors influencing the dispersion of indoor radon concentration over the territory are as follows: area of territory, sample size, characteristics of measurements technique, the radon geogenic potential, building construction characteristics and living habits. As shown for Sverdlovsk oblast and Niška Banja town the dispersion as quantified by GSD is reduced by restricting to certain levels of control factors. Application of the developed approach to characterization of the world population radon exposure is discussed. - Highlights: • Influence of lithosphere and anthroposphere on variance of indoor radon is found. • Level-by-level analysis reduces GSD by a factor of 1.9. • Worldwide GSD is underestimated.

  5. Indoor air quality in the Karns research houses: baseline measurements and impact of indoor environmental parameters on formaldehyde concentrations

    International Nuclear Information System (INIS)

    Matthews, T.G.; Fung, K.W.; Tromberg, B.J.; Hawthorne, A.R.

    1985-12-01

    Baseline indoor air quality measurements, a nine-month radon study, and an environmental parameters study examining the impact of indoor temperature (T) and relative humidity (RH) levels on formaldehyde (CH 2 O) concentrations have been performed in three unoccupied research homes located in Karns, Tennessee. Inter-house comparison measurements of (1) CH 2 O concentration, (2) CH 2 O emission rates from primary CH 2 O emission sources, (3) radon and radon daughter concentrations, and (4) air exchange rates indicate that the three homes are similar. The results of the nine-month radon study indicate indoor concentrations consistently below the EPA recommended level of 4 pCi/L. Evidence was found that crawl-space concentrations may be reduced using heat pump systems whose outdoor units circulate fresh air through the crawl-space. The modeled results of the environmental parameters study indicate approximate fourfold increases in CH 2 O concentrations from 0.07 to 0.27 ppM for seasonal T and RH conditions of 20 0 C, 30% RH and 29 0 C, 80% RH, respectively. Evaluation of these environmental parameters study data with steady-state CH 2 O concentration models developed from laboratory studies of the environmental dependence of CH 2 O emissions from particleboard underlayment indicate good correlations between the laboratory and field studies

  6. Indoor Environmental Quality Benefits of Apartment Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Noris, Federico [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Adamkiewicz, Gary [Harvard School of Public Health, Boston MA (United States); Delp, William W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hotchi, Toshifumi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Russell, Marion [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Spears, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Vermeer, Kimberly [Urban Habitate Initiatives Inc., Boston, MA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-06-01

    Sixteen apartments serving low-income populations in three buildings were retrofit with the goal of simultaneously reducing energy consumption and improving indoor environmental quality (IEQ). Retrofit measures varied among apartments and included, among others, envelope sealing, installation of continuous mechanical ventilation systems, upgrading bathroom fans and range hoods, attic insulation, replacement of heating and cooling systems, and adding wall-mounted particle air cleaners. IEQ parameters were measured, generally for two one-week periods before and after the retrofits. The measurements indicate an overall improvement in IEQ conditions after the retrofits. Comfort conditions, bathroom humidity, and concentrations of carbon dioxide, acetaldehyde, volatile organic compounds, and particles generally improved. Formaldehyde and nitrogen dioxide levels decreased in the building with the highest concentrations, were unchanged in a second building, and increased in a third building. IEQ parameters other than particles improved more in apartments with continuous mechanical ventilation systems installed. In general, but not consistently, larger percent increases in air exchange rates were associated with larger percent decreases in indoor levels of the pollutants that primarily come from indoor sources.

  7. Indoor environment and allergy except housedust mite; Jukankyo to allergy ni kansuru dani igai no chosa kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, F.; Nishima, S.

    1998-05-31

    Pathopoiesis factors of allergic diseases include immune antibody productivity sthenia reacting with antigens such as mite or the like in allergy reaction which is regarded as based on genetic fact (atopic diathesis), and environmental factors as external factors. The environmental factors are further classified into specific factors (antigens) and nonspecific factors. The former factors include the indoor factors such as mite, mould, animals bred indoor, etc., and outdoor factors such as pollen and so on. The latter factors include indoor factors such as passive smoking, carbon monoxide, nitrogen oxides, formaldehyde, etc., and outdoor factors such as sulfur oxides, nitrogen oxides, airborne particles and so on. In this paper, the environmental factors in relation to allergic diseases expect mite are introduced. Besides mould, cockroach/insect, fur dust and dandruff of animals, adjustment of room temperature/humidity, smoking, indoor and outdoor air pollution are mentioned as the environmental factors expect mite, and the cause-effect relations thereof are explained. 24 refs., 3 figs., 7 tabs.

  8. Indoor air-assessment: Indoor concentrations of environmental carcinogens

    International Nuclear Information System (INIS)

    Gold, K.W.; Naugle, D.F.; Berry, M.A.

    1991-01-01

    In the report, indoor concentration data are presented for the following general categories of air pollutants: radon-222, environmental tobacco smoke (ETS), asbestos, gas phase organic compounds, formaldehyde, polycyclic aromatic hydrocarbons (PAH), pesticides, and inorganic compounds. These pollutants are either known or suspect carcinogens (i.e., radon-222, asbestos) or more complex mixtures or classes of compounds which contain known or suspect carcinogens. Concentration data for individual carcinogenic compounds in complex mixtures are usually far from complete. The data presented for complex mixtures often include compounds which are not carcinogenic or for which data are insufficient to evaluate carcinogenicity. Their inclusion is justified, however, by the possibility that further work may show them to be carcinogens, cocarcinogens, initiators or promotors, or that they may be employed as markers (e.g., nicotine, acrolein) for the estimation of exposure to complex mixtures

  9. Preventing Skin Cancer Through Reduction of Indoor Tanning

    Science.gov (United States)

    Watson, Meg; Holman, Dawn M.; Fox, Kathleen A.; Guy, Gery P.; Seidenberg, Andrew B.; Sampson, Blake P.; Sinclair, Craig; Lazovich, DeAnn

    2015-01-01

    Exposure to ultraviolet radiation from indoor tanning devices (tanning beds, booths, and sun lamps) or from the sun contributes to the risk of skin cancer, including melanoma, which is the type of skin cancer responsible for most deaths. Indoor tanning is common among certain groups, especially among older adolescents and young adults, adolescent girls and young women, and non-Hispanic whites. Increased understanding of the health risks associated with indoor tanning has led to many efforts to reduce use. Most environmental and systems efforts in the U.S. (e.g., age limits or requiring parental consent/accompaniment) have occurred at the state level. At the national level, the U.S. Food and Drug Administration and the Federal Trade Commission regulate indoor tanning devices and advertising, respectively. The current paper provides a brief review of (1) the evidence on indoor tanning as a risk factor for skin cancer; (2) factors that may influence use of indoor tanning devices at the population level; and (3) various environmental and systems options available for consideration when developing strategies to reduce indoor tanning. This information provides the context and background for the companion paper in this issue of the American Journal of Preventive Medicine, which summarizes highlights from an informal expert meeting convened by the CDC in August 2012 to identify opportunities to prevent skin cancer by reducing use of indoor tanning devices. PMID:23683987

  10. Energy impact of indoor environmental policy for air-conditioned offices of Hong Kong

    International Nuclear Information System (INIS)

    Wong, L.T.; Mui, K.W.; Shi, K.L.

    2008-01-01

    Air-conditioned office buildings are one of the biggest energy consumers of electricity in developed cities in the subtropical climate regions. A good energy policy for the indoor environment should respond to both the needs of energy conservation and the needs for a desirable indoor healthy environment with a reduction in carbon dioxide (CO 2 ) generation. This study evaluates energy implications and the corresponding CO 2 generation of some indoor environmental policies for air-conditioned office buildings in the subtropical climate. In particular, the thermal energy consumption in an air-conditioned office building was evaluated by the heat gains through the building fabric, the transport of outdoor fresh air for ventilation, and the heat generated by the occupant and equipment in the space. With the Monte-Carlo sampling technique and the parameters from the existing office building stocks of Hong Kong, the energy consumption profiles of air-conditioned office buildings in Hong Kong were evaluated. Energy consumption profiles were simulated for certain indoor environmental quality (IEQ) policies on indoor air temperature and CO 2 concentration settings in the offices, with other building parameters remaining unchanged. The impact assessment and the regression models described in this study may be useful for evaluation of energy performances of IEQ policies. They will also be useful for the promotion of energy-saving measures in air-conditioned office buildings in Hong Kong. This study presented a useful source of references for policymakers, building professionals and end users to quantify the energy and environmental impacts due to an IEQ policy for air-conditioned office buildings

  11. Indoor environmental quality and ventilation in U.S. office buildings: A view of current issues

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, W.J.

    1994-11-01

    Much of the current focus on indoor environmental quality and ventilation in US office buildings is a response to sick building syndrome and occupant complaints about building-related health symptoms, poor indoor air quality, and thermal discomfort. The authors know that serious ``sick-building`` problems occur in a significant number of US office buildings and that a significant proportion of the occupants in many normal (non-sick) buildings report building-related health symptoms. Concerns about the health effects of environmental tobacco smoke have also focused attention on the indoor environment. The major responses of industry and governments, underway at the present time, are to restrict smoking in offices, to attempt to reduce the emissions of indoor pollutants, and to improve the operation of heating, ventilating and air conditioning (HVAC) systems. Better air filtration, improved HVAC commissioning and maintenance, and increased provisions for individual control of HVAC are some of the improvements in HVAC that are currently being, evaluated. In the future, the potential for improved productivity and reduced airborne transmission of infectious disease may become the major driving force for improved indoor environments.

  12. Effects of Inhalation of Emissions from Cedar Timber on Psychological and Physiological Factors in an Indoor Environment

    Directory of Open Access Journals (Sweden)

    Kenichi Azuma

    2016-12-01

    Full Text Available Components extracted from cedar timber have been reported to have stress-reducing effects in humans. If the positive effects of cedar timber in indoor environments are scientifically proven, an indoor environment that utilizes cedar timber may contribute to the improvement or promotion of well-being in humans. In this study, we evaluated the effects of inhaling emissions of volatile constituents from cedar timber (Cryptomeria japonica on the psychological and physiological factors in indoor environments. A case-control study with a crossover design was conducted with 10 subjects occupying two rooms that were controlled for interior materials, indoor climate, and room size. Cedrol and β-eudesmol were specifically detected in the case room. However, no significant differences were observed in psychological and physiological factors. There was a significant loss in vigor in the control group from the time before entering the room to the time after leaving the room; however, this loss in vigor was not seen in the case group. Temperature conditions were higher than the indoor environmental standard in Japan but similar in the two groups. Our results showed a minor positive change in vigor among participants exposed to cedar timber for a short term. Inhalation of emissions of volatile constituents from cedar timber may have positive effects in humans; however, further research on their efficacy is needed.

  13. Individual and environmental risk factors for high blood lead concentrations in Danish indoor shooters

    DEFF Research Database (Denmark)

    Grandahl, Kasper; Suadicani, Poul; Jacobsen, Peter

    2012-01-01

    International studies have shown blood lead at levels causing health concern in recreational indoor shooters. We hypothesized that Danish recreational indoor shooters would also have a high level of blood lead, and that this could be explained by shooting characteristics and the physical...

  14. The effects of indoor environmental exposures on pediatric asthma: a discrete event simulation model

    Directory of Open Access Journals (Sweden)

    Fabian M Patricia

    2012-09-01

    Full Text Available Abstract Background In the United States, asthma is the most common chronic disease of childhood across all socioeconomic classes and is the most frequent cause of hospitalization among children. Asthma exacerbations have been associated with exposure to residential indoor environmental stressors such as allergens and air pollutants as well as numerous additional factors. Simulation modeling is a valuable tool that can be used to evaluate interventions for complex multifactorial diseases such as asthma but in spite of its flexibility and applicability, modeling applications in either environmental exposures or asthma have been limited to date. Methods We designed a discrete event simulation model to study the effect of environmental factors on asthma exacerbations in school-age children living in low-income multi-family housing. Model outcomes include asthma symptoms, medication use, hospitalizations, and emergency room visits. Environmental factors were linked to percent predicted forced expiratory volume in 1 second (FEV1%, which in turn was linked to risk equations for each outcome. Exposures affecting FEV1% included indoor and outdoor sources of NO2 and PM2.5, cockroach allergen, and dampness as a proxy for mold. Results Model design parameters and equations are described in detail. We evaluated the model by simulating 50,000 children over 10 years and showed that pollutant concentrations and health outcome rates are comparable to values reported in the literature. In an application example, we simulated what would happen if the kitchen and bathroom exhaust fans were improved for the entire cohort, and showed reductions in pollutant concentrations and healthcare utilization rates. Conclusions We describe the design and evaluation of a discrete event simulation model of pediatric asthma for children living in low-income multi-family housing. Our model simulates the effect of environmental factors (combustion pollutants and allergens

  15. Environmental risk factors of childhood asthma in urban centers.

    OpenAIRE

    Malveaux, F J; Fletcher-Vincent, S A

    1995-01-01

    Asthma morbidity and mortality are disproportionately high in urban centers, and minority children are especially vulnerable. Factors that contribute to this dilemma include inadequate preventive medical care for asthma management, inadequate asthma knowledge and management skills among children and their families, psychosocial factors, and environmental exposure to allergens or irritants. Living in substandard housing often constitutes excess exposure to indoor allergens and pollutants. Alle...

  16. Meteorological factors influencing on the radon concentrations in indoor and outdoor airs

    International Nuclear Information System (INIS)

    Kojima, Hiroshi

    1989-01-01

    Factors influencing radon concentrations in indoor and outdoor airs are discussed. A balance between source and loss is required in determining the radon concentration. Source refers to as the outdoor and indoor exhalation rate from the ground and the building materials. Loss is caused by turbulent diffusion outdoors and ventilation indoors. A significant factor influencing the exhalation rate of indoor and outdoor radon may be the change in atmospheric pressure. A drop of pressure feeds the high concentration air under the ground or building materials into the open air, and contributes to the increased exhalation rate. The exhalation rate of radon closely depends on the moisture content of the ground or building materials. Up to a certain level of moisture, the radon exhalation increases with increasing moisture content because the emanation power increases by a recoil effect of a fluid present in the internal pores of the materials. Beyond a certain level of moisture, the exhalation decreases rapidly because the pores are filled with water. Radon exhalated from the ground is spread out by turbulent diffusion. The turbulent diffusion may be related to wind velocity and the lapse rate of temperature. There is a remakable difference between indoor and outdoor radon concentrations. The ventilation rate of the house exerted a great effect upon the indoor radon concentration. The ventilation rate is influenced by meteorological factors together with human activities. Of such factors, wind velocity and temperature gradient between indoor and outdoor airs may be the most significant. The correlation coefficients between RaA or radon and some meteorological factors were calculated on the data from the long term measurements on radon and its decay products in and out of a house under normal living conditions. The changes in atmospheric pressure and wind velocity are found to be a significant factor in the variation of concentration of these nuclides. (N.K.)

  17. Long term and equilibrium factor indoor radon measurements

    International Nuclear Information System (INIS)

    Martinez, T.; Lartigue, J.; Navarrete, M.; Cabrera, L.; Ramirez, A.; Elizarraras, V.

    1998-01-01

    This paper presents the annual radon gas concentrations obtained during the 1994-1995 monitoring campaign using passive electret system (type E-PERM). Radon levels were measured in 154 single family dwellings, in normal occupancy conditions (open house condition) in the metropolitan zone of Mexico City. At the same time radon monitoring was performed outdoors. The results show the general log-normal distribution of integrated indoor radon concentration with an annual indoor mean of 3.8 pCi x l -1 . The seasonal variations show the minimum mean values in the summer season which are 39% lower than that in autumn. Equilibrium factors (F) were measured in 12 typical houses both in autumn and winter using a continuous working level monitor for short-lived radon decay products and H-chamber loaded with a short term electret (HST, E-PERM) for radon gas. The obtained total mean equilibrium factors are: F=0.41±0.17 and F=0.29±0.04 for indoor and outdoor, respectively. A quality program was also improved. (author)

  18. Reevaluation of time spent indoors used for exposure dose assessment

    International Nuclear Information System (INIS)

    Hirose, Katsumi; Fujimoto, Kenzo

    2016-01-01

    A time spent indoors of sixteen hours per day (indoor occupancy factor: 0.67) has been used to assess the radiation dose of residents who spend daily life in the area contaminated due to the nuclear accident in Japan. However, much longer time is considered to be spent indoors for recent modern life. United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) has been used an indoor occupancy factor of 0.8 since 1977 and a few reports suggested much higher indoor occupancy factors. Therefore it is important to reevaluate the indoor occupancy factor using current available survey data in Japan, such as 'NHK 2010 National Time Use Survey' and 'Survey on Time Use and Leisure Activities' of Statistics Bureau with certain assumption of time spent indoors in each daily activity. The total time spent indoors in a day is calculated to be 20.2 hours and its indoor occupancy factor is 0.84. Much lower indoor occupancy factors were derived from the survey data by Statistics Bureau for 10 to 14 and 15 to 19 years old groups and farmers who spend most of their time outdoors although present estimated indoor occupancy factor of 0.84 is still lower than those found in some of the relevant reports. A rounded indoor occupancy factor of 0.80 might be the appropriate conservative reference value to be used for the dose estimation of people who live in radioactively contaminated areas and for other relevant purposes of exposure assessment, taken into consideration the present results and values reported in United States Environmental Protection Agency (US EPA) and UNSCEAR. (author)

  19. Human comfort and self-estimated performance in relation to indoor environmental parameters and building features

    DEFF Research Database (Denmark)

    Frontczak, Monika Joanna

    The main objective of the Ph.D. study was to examine occupants’ perception of comfort and self-estimated job performance in non-industrial buildings (homes and offices), in particular how building occupants understand comfort and which parameters, not necessarily related to indoor environments...... and storage, noise level and visual privacy. However, if job performance is considered, then satisfaction with the main indoor environmental parameters should be addressed first as they affected self-estimated job performance to the highest extent. The present study showed that overall satisfaction...... with personal workspace affected significantly the self-estimated job performance. Increasing overall satisfaction with the personal workspace by about 15% would correspond to an increase of self-estimated job performance by 3.7%. Among indoor environmental parameters and building features, satisfaction...

  20. Indoor environment and pupils' health in primary schools

    DEFF Research Database (Denmark)

    van Dijken, F.; van Bronswijk, J.E.M.H.; Sundell, Jan

    2006-01-01

    the associations between indoor environmental quality in Dutch schools and pupils' health, also taking into account the children's home environment and personal factors. A cross-sectional study was performed in 11 classrooms in 11 different schools in the Netherlands. The study included exposure measurements......Dutch children are legally bound to spend 15% of their time in a school setting. The indoor environment in Dutch primary schools is known to be substandard. However, it is unclear to what extent the health of pupils is affected by the indoor school environment. The paper aims to assess......, building inspections, and a questionnaire survey on pupils' health and domestic exposure. Principal Component Analysis (PCA) and non-parametric tests were performed to assess relationships. None of the schools complied with all indoor environmental quality standards. The importance of both the school...

  1. Indoor environmental and air quality characteristics, building-related health symptoms, and worker productivity in a federal government building complex.

    Science.gov (United States)

    Lukcso, David; Guidotti, Tee Lamont; Franklin, Donald E; Burt, Allan

    2016-01-01

    Building Health Sciences, Inc. (BHS), investigated environmental conditions by many modalities in 71 discreet areas of 12 buildings in a government building complex that had experienced persistent occupant complaints despite correction of deficiencies following a prior survey. An online health survey was completed by 7,637 building occupants (49% response rate), a subset of whom voluntarily wore personal sampling apparatus and underwent medical evaluation. Building environmental measures were within current standards and guidelines, with few outliers. Four environmental factors were consistently associated with group-level building-related health complaints: physical comfort/discomfort, odor, job stress, and glare. Several other factors were frequently commented on by participants, including cleanliness, renovation and construction activities, and noise. Low relative humidity was significantly associated with lower respiratory and "sick building syndrome"-type symptoms. No other environmental conditions (including formaldehyde, PM10 [particulate matter with an aerodynamic diameter work but at reduced capacity), and increase in reported symptom-days, including symptoms not related to respiratory disease. We found that in buildings without unusual hazards and with environmental and air quality indicators within the range of acceptable indoor air quality standards, there is an identifiable population of occupants with a high prevalence of asthma and allergic disease who disproportionately report discomfort and lost productivity due to symptoms and that in "normal" buildings these outcome indicators are more closely associated with host factors than with environmental conditions. We concluded from the experience of this study that building-related health complaints should be investigated at the work-area level and not at a building-wide level. An occupant-centric medical evaluation should guide environmental investigations, especially when screening results of building

  2. Factors affecting the concentration of outdoor particles indoors: Existing data and data needs

    International Nuclear Information System (INIS)

    McKone, T.E.; Thatcher, T.L.; Fisk, W.J.; Sextro, R.G.; Sohn, M.D.; Delp, W.W.; Riley, W.J.

    2002-01-01

    Accurate characterization of particle concentrations indoors is critical to exposure assessments. It is estimated that indoor particle concentrations depend strongly on outdoor concentrations. For health scientists, knowledge of the factors that control the relationship of indoor particle concentrations to outdoor levels is particularly important. In this paper, we identify and evaluate sources of data for those factors that affect the transport to and concentration of outdoor particles indoors. To achieve this goal, we (i) identify and assemble relevant information on how particle behavior during air leakage, HVAC operation, and particle filtration effects indoor particle concentration; (ii) review and evaluate the assembled information to distinguish data that are directly relevant to specific estimates of particle transport from those that are only indirectly useful; and (iii) provide a synthesis of the currently available information on building air-leakage parameters and their effect on indoor particle matter concentrations

  3. Quantitative relationships between occupant satisfaction and satisfaction aspects of indoor environmental quality and building design

    DEFF Research Database (Denmark)

    Frontczak, Monika Joanna; Schiavon, S.; Goins, J.

    2012-01-01

    The article examines which subjectively evaluated indoor environmental parameters and building features mostly affect occupants' satisfaction in mainly US office buildings. The study analyzed data from a web-based survey administered to 52 980 occupants in 351 office buildings over 10 years...... by the Center for the Built Environment. The survey uses 7-point ordered scale questions pertaining to satisfaction with indoor environmental parameters, workspace, and building features. The average building occupant was satisfied with his/her workspace and building. Proportional odds ordinal logistic...

  4. Indoor air quality – buildings design

    Directory of Open Access Journals (Sweden)

    Juhásová Šenitková Ingrid

    2017-01-01

    Full Text Available Growing attention is being paid to indoor air quality as one of the main health and well-being factors. The indoor research is concerned mostly to indoor air chemicals within indoor engineering related to building design. The providing good indoor air quality can be achieved effectively by avoiding or reducing indoor air pollution sources and by selecting low-polluting building materials, both being low-cost and energyefficient solutions. On the base of the last large experimental monitoring results, it was possible to know the level of selected indoor chemicals occurrence, rank them as well as to predict the tendencies of occurrence and establish the priorities for the future. There has been very limited attention to rigorous analysis of buildings actual environmental impacts to date. Healthy/green/sustainable building practices are typically applied in unsystematic and inconsistent ways often without resolution of inherent conflicts between and among such practices. Designers, products manufacturers, constructors, and owners declare their buildings and the applied technologies to be beneficial to the environment without validating those claims.

  5. Source apportionment for indoor PM2.5 and elemental concentrations using by a positive matrix factorization and an instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lim, Jong Myoung; Moon, Jong Hwa; Chung, Yong Sam; Jung, Byoung Won; Lee, Jin Hong

    2009-01-01

    Airborne particulate matters, especially the PM2.5 (aerodynamic equivalent diameter, AED, less than 2.5 μm) fraction has been important. This is because of their potential for deposition on to the human respiratory system being accompanied by many harmful trace metals (such as As, Cd, Cr, Cu, Mn, Pb, Se, and Zn). The indoor air quality has become a great concern since late 1980s, because the population spends a majority of their time in various indoor environments. The indoor particulate matter may be influenced from outdoor environment and indoor sources such as environmental tobacco smoke (ETS), combustion devices, cooking, etc. In this study, we undertake the measurements of about 26 elements using instrumental neutron activation analysis (INAA). Based on our measurement data, we characterize concentration status and mutual relationship between indoor and adjacent outdoor air quality. Next, sources at indoor/outdoor environment were identified and the contributions of each source were quantified by positive matrix factorization (PMF)

  6. Indoor Environment Program

    International Nuclear Information System (INIS)

    Daisey, J.M.

    1993-06-01

    This paper reports progress during the year 1992 in the Indoor Environment Program in the Energy and Environment Division of Lawrence Berkeley Laboratory. Studies in the following areas are reported: energy performance and ventilation in buildings; physical and chemical characterization of indoor air pollutants; indoor radon; indoor air quality; exposure to indoor air pollutants and risk analysis. Pollutants of particular interest include: radon; volatile, semi-volatile and particulate organic compounds; and combustion emissions including environmental tobacco smoke, carbon monoxide, and nitrogen oxides

  7. Effects of Ambient Environmental Factors on the Stereotypic Behaviors of Giant Pandas (Ailuropoda melanoleuca).

    Science.gov (United States)

    Liu, He; Duan, Hejun; Wang, Cheng

    2017-01-01

    Stereotypies are commonly observed in zoo animals, and it is necessary to better understand whether ambient environmental factors contribute to stereotypy and how to affect animal welfare in zoo settings. This study investigated the relationships between stereotypic behaviors and environmental factors including ambient temperatures, humidity, light intensity, sound intensity and number of visitors. Seven giant pandas were observed in three indoor enclosures and three outdoor enclosures. Environmental factors were measured for both indoor and outdoor enclosures and the effect they had on stereotypical behaviors was investigated. Our research found that light intensity significantly correlated with all stereotypies behaviors. Higher environmental temperature reduced the duration of pacing but increased the frequency of pacing, the duration and frequency of door-directed, meanwhile the duration of head-toss. However, we found no noticeable effect of humidity on stereotypic behaviors except for the frequency of head-toss. We also found that sound intensity was not correlated with stereotypies. Finally, the growth of visitors was negatively associated with the duration of door-directed. These results demonstrated that various environmental factors can have significant effects on stereotypic behaviors causing the expression of various stereotypies. Thus, stereotypies in zoo animals may not simply represent suboptimal welfare, but rather might be adopted as a means of coping with an aversive environment.

  8. Preventing skin cancer through reduction of indoor tanning: current evidence.

    Science.gov (United States)

    Watson, Meg; Holman, Dawn M; Fox, Kathleen A; Guy, Gery P; Seidenberg, Andrew B; Sampson, Blake P; Sinclair, Craig; Lazovich, DeAnn

    2013-06-01

    Exposure to ultraviolet radiation from indoor tanning devices (tanning beds, booths, and sun lamps) or from the sun contributes to the risk of skin cancer, including melanoma, which is the type of skin cancer responsible for most deaths. Indoor tanning is common among certain groups, especially among older adolescents and young adults, adolescent girls and young women, and non-Hispanic whites. Increased understanding of the health risks associated with indoor tanning has led to many efforts to reduce use. Most environmental and systems efforts in the U.S. (e.g., age limits or requiring parental consent/accompaniment) have occurred at the state level. At the national level, the U.S. Food and Drug Administration and the Federal Trade Commission regulate indoor tanning devices and advertising, respectively. The current paper provides a brief review of (1) the evidence on indoor tanning as a risk factor for skin cancer; (2) factors that may influence use of indoor tanning devices at the population level; and (3) various environmental and systems options available for consideration when developing strategies to reduce indoor tanning. This information provides the context and background for the companion paper in this issue of the American Journal of Preventive Medicine, which summarizes highlights from an informal expert meeting convened by the CDC in August 2012 to identify opportunities to prevent skin cancer by reducing use of indoor tanning devices. Published by Elsevier Inc.

  9. Fieldwork measurement of indoor environmental quality (IEQ) in Malaysian platinum-rated green office buildings

    Science.gov (United States)

    Tharim, Asniza Hamimi Abdul; Samad, Muna Hanim Abdul; Ismail, Mazran

    2017-10-01

    An Indoor Environmental Quality (IEQ) fieldwork assessment was conducted in the Platinum-rated GBI office building located in Putrajaya Malaysia. The aim of the study is to determine the current indoor performance of the selected green office building. The field measurement consists of several IEQ parameters counted under the GBI Malaysia namely the Thermal Comfort of temperature, relative humidity, air movement and heat transfer as well as solar radiation. This field measurement also comprises of the measurement for the background noise, visual lighting and Indoor Air Quality (IAQ) focusing on the aspect of carbon dioxide concentration. All the selected indoor parameters were measured for the period of five working days and the results were compared to the Malaysian Standard. Findings of the field measurement show good indoor performance of the Platinum rated office building that complies with the GBI standard. It is hoped that the research findings will be beneficial for future design and construction of office building intended to be rated under the GBI Malaysia.

  10. A study of diurnal variations of radon and thoron concentrations in different indoor environmental conditions

    International Nuclear Information System (INIS)

    Pant, Preeti; Prasad, Mukesh; Ramola, R.C.

    2015-01-01

    The measurements for diurnal variations in radon ( 222 Rn) and thoron ( 220 Rn) concentrations were performed in the different indoor conditions of Tehri Garhwal, Uttarakhand, India by using AlphaGUARD, Portable Radon Monitor and RAD7. While selecting the dwellings, the ventilation conditions, building materials, life style of the inhabitants and their exposure time indoors were also considered. The behavior of indoor radon and thoron concentrations was observed for different type of dwellings with different environmental conditions. The measurement techniques, results obtained and comparison of the results are discussed in details. (author)

  11. The distribution of indoor radon in Transylvania (Romania) - influence of the natural and anthropogenic factors

    Science.gov (United States)

    Cucos Dinu, Alexandra; Baciu, Calin; Dicu, Tiberius; Papp, Botond; Moldovan, Mircea; Bety Burghele, Denissa; Tenter, Ancuta; Szacsvai, Kinga

    2017-04-01

    Exposure to radon in homes and workplaces is now recognized as the most important natural factor in causing lung cancer. Radon activity is usually higher in buildings than in the outside atmosphere, as it may be released from building materials and soil beneath the constructions, and the concentration builds-up indoor, due to the low air renewal rates. Indoor radon levels can vary from one to multiple orders of magnitude over time and space, as it depends on several natural and anthropogenic factors, such us the radon concentration in soil under the construction, the weather conditions, the degree of containment in the areas where individuals are exposed, building materials, outside air, tap water and even city gas, the architecture, equipment (chimney, mechanical ventilation systems, etc.), the environmental parameters of the building (temperature, pressure, etc.), and on the occupants' lifestyle. The study presents the distribution of indoor radon in Transylvania, Romania, together with the measurements of radon in soil and soil water. Indoor radon measurements were performed by using CR-39 track detectors exposed for 3 months on ground-floor level of dwellings, according to the NRPB Measurement Protocol. Radon concentrations in soil and water were measured using the LUK3C device. A complete map was plotted at the date, based on 3300 indoor radon measurements, covering an area of about 42% of the Romanian territory. The indoor radon concentrations ranged from 5 to 3287 Bq m-3, with an updated preliminary arithmetic mean of 179 Bq m-3, and a geometric mean of 122 Bq m-3. In about 11% of the investigated grid cells the indoor radon concentrations exceed the threshold of 300 Bq m-3. The soil gas radon concentration varies from 0.8 to 169 kBq m-3, with a geometric mean of 26 kBq m-3. For water samples, the results show radon concentrations within the range of 0.3 - 352.2 kBq m-3, with a geometric mean of 7.7 Bq L-1. A weak correlation between the three sets of values

  12. Personal, Psychosocial and Environmental Factors Related to Sick Building Syndrome in Official Employees of Taiwan

    Directory of Open Access Journals (Sweden)

    Chung-Yen Lu

    2017-12-01

    Full Text Available Sick building syndrome (SBS is a combination of symptoms that can be attributed to exposure to specific building conditions. The present study recruited 389 participants aged 20–65 years from 87 offices of 16 institutions to examine if personal factors, work-related psychosocial stress, and work environments, were associated with five groups of SBS symptoms, including symptoms for eyes, upper respiratory tract, lower respiratory tract, skin, and non-specific systems. Indoor environmental conditions were monitored. Data were analyzed using multivariate logistic regression (MLR analyses and were reported as adjusted Odds Ratios (aOR. SBS symptoms for eyes were associated with older age, sensitivity to tobacco, and low indoor air flow. Upper respiratory symptoms were related to smoking, low social support, longer work days, and dry air. High indoor air flow was associated with reduced upper respiratory symptoms (aOR = 0.29; 95% confidence interval (CI = 0.13–0.67. Lower respiratory symptoms were associated with high work pressure, longer work hours, chemical exposure, migraine, and exposure to new interior painting. Recent interior painting exposure was associated with a high estimated relative risk of low respiratory symptoms (aOR = 20.6; 95% CI = 2.96–143. Smoking, longer work days, low indoor air flow, indoor dryness, and volatile organics exposure, were associated with other non-specified symptoms including headache, tiredness, difficulty concentrating, anger, and dizziness. In conclusion, there are various SBS symptoms associated with different personal characteristics, psychosocial, and environmental factors. Psychosocial factors had stronger relationships with lower respiratory symptoms than with other types of SBS symptoms. Good ventilation could reduce risk factors and may relieve SBS symptoms.

  13. Indoor Environmental Quality in Mechanically Ventilated, Energy-Efficient Buildings vs. Conventional Buildings.

    Science.gov (United States)

    Wallner, Peter; Munoz, Ute; Tappler, Peter; Wanka, Anna; Kundi, Michael; Shelton, Janie F; Hutter, Hans-Peter

    2015-11-06

    Energy-efficient buildings need mechanical ventilation. However, there are concerns that inadequate mechanical ventilation may lead to impaired indoor air quality. Using a semi-experimental field study, we investigated if exposure of occupants of two types of buildings (mechanical vs. natural ventilation) differs with regard to indoor air pollutants and climate factors. We investigated living and bedrooms in 123 buildings (62 highly energy-efficient and 61 conventional buildings) built in the years 2010 to 2012 in Austria (mainly Vienna and Lower Austria). Measurements of indoor parameters (climate, chemical pollutants and biological contaminants) were conducted twice. In total, more than 3000 measurements were performed. Almost all indoor air quality and room climate parameters showed significantly better results in mechanically ventilated homes compared to those relying on ventilation from open windows and/or doors. This study does not support the hypothesis that occupants in mechanically ventilated low energy houses are exposed to lower indoor air quality.

  14. Associations between indoor environmental factors and parental-reported autistic spectrum disorders in children 6-8 years of age

    DEFF Research Database (Denmark)

    Larsson, Malin; Weiss, Bernard; Janson, Staffan

    2009-01-01

    autism spectrum disorder. A random sample of 10 such families confirmed that the diagnoses had been made by medical professionals, in accordance with the Swedish system for monitoring children's health. An analysis of the associations between indoor environmental variables in 2000 as well as other......Potential contributions of environmental chemicals and conditions to the etiology of Autism Spectrum Disorders are the subject of considerable cur-rent research and speculation. The present paper describes the results of a study undertaken as part of a larger project devoted to the connection......, follow-up questionnaire (DBH-III) was distributed in 2005. The original survey collected information about the child, the family situation, practices such as smoking, allergic symptoms, type of residence, moisture-related problems, and type of flooring material, which included polyvinyl chloride (PVC...

  15. Relationships between socioeconomic and lifestyle factors and indoor air quality in French dwellings.

    Science.gov (United States)

    Brown, Terry; Dassonville, Claire; Derbez, Mickael; Ramalho, Olivier; Kirchner, Severine; Crump, Derrick; Mandin, Corinne

    2015-07-01

    To date, few studies have analyzed the relationships between socioeconomic status (SES) and indoor air quality (IAQ). The aim of this study was to examine the relationships between socioeconomic and other factors and indoor air pollutant levels in French homes. The indoor air concentrations of thirty chemical, biological and physical parameters were measured over one week in a sample of 567 dwellings representative of the French housing stock between September 2003 and December 2005. Information on SES (household structure, educational attainment, income, and occupation), building characteristics, and occupants' habits and activities (smoking, cooking, cleaning, etc.) were collected through administered questionnaires. Separate stepwise linear regression models were fitted to log-transformed concentrations on SES and other factors. Logistic regression was performed on fungal contamination data. Households with lower income were more likely to have higher indoor concentrations of formaldehyde, but lower perchloroethylene indoor concentrations. Formaldehyde indoor concentrations were also associated with newly built buildings. Smoking was associated with increasing acetaldehyde and PM2.5 levels and the risk of a positive fungal contamination index. BTEX levels were also associated with occupant density and having an attached garage. The major predictors for fungal contamination were dampness and absolute humidity. These results, obtained from a large sample of dwellings, show for the first time in France the relationships between SES factors and indoor air pollutants, and believe they should be considered alongside occupant activities and building characteristics when study IAQ in homes. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  16. Predicted and actual indoor environmental quality: Verification of occupants' behaviour models in residential buildings

    DEFF Research Database (Denmark)

    Andersen, Rune Korsholm; Fabi, Valentina; Corgnati, Stefano P.

    2016-01-01

    with the building controls (windows, thermostats, solar shading etc.). During the last decade, studies about stochastic models of occupants' behaviour in relation to control of the indoor environment have been published. Often the overall aim of these models is to enable more reliable predictions of building...... performance using building energy performance simulations (BEPS). However, the validity of these models has only been sparsely tested. In this paper, stochastic models of occupants' behaviour from literature were tested against measurements in five apartments. In a monitoring campaign, measurements of indoor....... However, comparisons of the average stochastic predictions with the measured temperatures, relative humidity and CO2 concentrations revealed that the models did not predict the actual indoor environmental conditions well....

  17. Sampling strategies for indoor radon investigations

    International Nuclear Information System (INIS)

    Prichard, H.M.

    1983-01-01

    Recent investigations prompted by concern about the environmental effects of residential energy conservation have produced many accounts of indoor radon concentrations far above background levels. In many instances time-normalized annual exposures exceeded the 4 WLM per year standard currently used for uranium mining. Further investigations of indoor radon exposures are necessary to judge the extent of the problem and to estimate the practicality of health effects studies. A number of trends can be discerned as more indoor surveys are reported. It is becoming increasingly clear that local geological factors play a major, if not dominant role in determining the distribution of indoor radon concentrations in a given area. Within a giving locale, indoor radon concentrations tend to be log-normally distributed, and sample means differ markedly from one region to another. The appreciation of geological factors and the general log-normality of radon distributions will improve the accuracy of population dose estimates and facilitate the design of preliminary health effects studies. The relative merits of grab samples, short and long term integrated samples, and more complicated dose assessment strategies are discussed in the context of several types of epidemiological investigations. A new passive radon sampler with a 24 hour integration time is described and evaluated as a tool for pilot investigations

  18. Effects of Ambient Environmental Factors on the Stereotypic Behaviors of Giant Pandas (Ailuropoda melanoleuca.

    Directory of Open Access Journals (Sweden)

    He Liu

    Full Text Available Stereotypies are commonly observed in zoo animals, and it is necessary to better understand whether ambient environmental factors contribute to stereotypy and how to affect animal welfare in zoo settings. This study investigated the relationships between stereotypic behaviors and environmental factors including ambient temperatures, humidity, light intensity, sound intensity and number of visitors. Seven giant pandas were observed in three indoor enclosures and three outdoor enclosures. Environmental factors were measured for both indoor and outdoor enclosures and the effect they had on stereotypical behaviors was investigated. Our research found that light intensity significantly correlated with all stereotypies behaviors. Higher environmental temperature reduced the duration of pacing but increased the frequency of pacing, the duration and frequency of door-directed, meanwhile the duration of head-toss. However, we found no noticeable effect of humidity on stereotypic behaviors except for the frequency of head-toss. We also found that sound intensity was not correlated with stereotypies. Finally, the growth of visitors was negatively associated with the duration of door-directed. These results demonstrated that various environmental factors can have significant effects on stereotypic behaviors causing the expression of various stereotypies. Thus, stereotypies in zoo animals may not simply represent suboptimal welfare, but rather might be adopted as a means of coping with an aversive environment.

  19. Correlation between Novel Potential Indoor Risk Factors and Frequency of Doctor's Visit for Respiratory Problem in Taiwan's Tropical Environment

    Directory of Open Access Journals (Sweden)

    Yu-Hao Wang

    2018-01-01

    Full Text Available Background: With a global rising trend in prevalence of allergic diseases, more attention has been paid to investigation of environmental risk factors. Many risk factors have so far been identified. However, novel risk factors specific to Taiwanese environment and lifestyle were still relatively unknown. Objective: To investigate the potential effects of a number of little-known indoor risk factors on the frequency of doctor's visit for respiratory problems in context of Taiwanese environment and lifestyle. Methods: A cross-sectional, population-based study was performed on a 861 participants around Kaohsiung area, Taiwan. Survey investigation was employed to assess the household environment and the frequency of doctor's visit for respiratory problems. Results: Participants who performed “daily cleaning” was shown to have a significantly (p=0.007 higher mean number of doctor's visits in comparison to those who did not. Similar observation was made for participants who periodically took out beddings (p=0.042. Age had a significant positive correlation (linear regression β 0.089 with frequency of respiratory problems. Conclusion: The habit of daily cleaning was implicated as a potential indoor risk factor due to the unique nature of Taiwanese cleaning habit and close contact with cleaning supplies, which could serve as chemical irritants. Bedding takeout was predicted to be an indicator of chronic allergies rather than an actual risk factor. However, both were controversial in their role as potential indoor risk factor, and required further examination.

  20. Indoor environmental health in schools

    Energy Technology Data Exchange (ETDEWEB)

    Small, B.M. [Envirodesic Certification Program, Stouffville, ON (Canada)

    1999-07-01

    Indoor health is a concern today because unhealthy environments can cause adverse health effects, poor learning and teaching and increased costs. The holistic view of the environment and human health links sick kids, absenteeism, teacher illness, education costs and mouldy schools. An historical perspective is provided on the problem and its treatment referring to: 1962 and chemical susceptibility, 1975 and open systems theory, 1978 and high risk groups, 1985 and pollution and education in Toronto, 1987 and health environments for Canadians, 1995 and the National Education Association in the U.S., 1997 and a U.S. Executive Order, 1998 and the Texas Dept. of Health, 1998 and the U.S. EPS website 'IAQ Tools for Schools', and 1998 and 'The air children breathe.' It is known that pollutants adversely affect health, that children are highly susceptible, that the role in schools has being known for decades, and that information is now available worldwide through the Internet. The reasons why mould is a problem are listed, and the effects of an unhealthy indoor environment are referred to. The benefits of a healthy indoor environment are listed, and the various means of creating a healthy indoor environment are outlined. New developments are referred to including: fresh air, building envelope, building leakage, airtightness of buildings, tight envelope and air supply, low-emission materials, maintenance and cleaning, strategy and financing, collaboration, and the possibility of healthy schools.

  1. Human comfort and self-estimated performance in relation to indoor environmental parameters and building features

    OpenAIRE

    Frontczak, Monika Joanna; Wargocki, Pawel

    2011-01-01

    The main objective of the Ph.D. study was to examine occupants’ perception of comfort and self-estimated job performance in non-industrial buildings (homes and offices), in particular how building occupants understand comfort and which parameters, not necessarily related to indoor environments, influence the perception of comfort.To meet the objective, the following actions were taken: (1) a literature survey exploring which indoor environmental parameters (thermal, acoustic, visualenvironmen...

  2. Indoor air quality : Tools for schools action kits for Canadian schools

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-01

    Few people realize that indoor air pollution can contribute to health effects like asthma. Several agencies, notably the United States Environmental Protection Agency (EPA), have indicated that levels of indoor pollutants can be significantly higher than those found outside. As such, poor indoor air quality (IAQ) could impact the health of students and staff, as well as the educational process and costs. Many factors can influence IAQ, including building materials, furnishings, cleaning agents, pesticides, printing and copying devices, and more. Reduction in IAQ can also result from tighter buildings and reduced ventilation. This kit was developed by Health Canada in collaboration with the Indoor Air Quality Working Group of the Federal-Provincial-Territorial Committee on Environmental and Occupational Health (CEOH) to provide school officials with the tools to prevent, identify, assess, and address most indoor air problems while minimizing cost and involvement. It was suggested that trained professionals should perform the limited and well-defined set of operations and maintenance activities described in the kit.

  3. Air Quality and Indoor Environmental Exposures: Clinical Impacts

    Science.gov (United States)

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more pol...

  4. Evaluation of indoor radon equilibrium factor using CFD modeling and resulting annual effective dose

    Science.gov (United States)

    Rabi, R.; Oufni, L.

    2018-04-01

    The equilibrium factor is an important parameter for reasonably estimating the population dose from radon. However, the equilibrium factor value depended mainly on the ventilation rate and the meteorological factors. Therefore, this study focuses on investigating numerically the influence of the ventilation rate, temperature and humidity on equilibrium factor between radon and its progeny. The numerical results showed that ventilation rate, temperature and humidity have significant impacts on indoor equilibrium factor. The variations of equilibrium factor with the ventilation, temperature and relative humidity are discussed. Moreover, the committed equivalent doses due to 218Po and 214Po radon short-lived progeny were evaluated in different tissues of the respiratory tract of the members of the public from the inhalation of indoor air. The annual effective dose due to radon short lived progeny from the inhalation of indoor air by the members of the public was investigated.

  5. Current state of the science: health effects and indoor environmental quality

    DEFF Research Database (Denmark)

    Mitchell, Clifford S; Zhang, Junfeng Jim; Sigsgaard, Torben

    2007-01-01

    Our understanding of the relationship between human health and the indoor environment continues to evolve. Previous research on health and indoor environments has tended to concentrate on discrete pollutant sources and exposures and on specific disease processes. Recently, efforts have been made...... environments. Advances in source characterization include a better understanding of how chemicals are transported and processed within spaces and the role that other factors such as lighting and building design may play in determining health. Efforts are under way to improve our ability to measure exposures...

  6. Medical diagnostics for indoor mold exposure.

    Science.gov (United States)

    Hurraß, Julia; Heinzow, Birger; Aurbach, Ute; Bergmann, Karl-Christian; Bufe, Albrecht; Buzina, Walter; Cornely, Oliver A; Engelhart, Steffen; Fischer, Guido; Gabrio, Thomas; Heinz, Werner; Herr, Caroline E W; Kleine-Tebbe, Jörg; Klimek, Ludger; Köberle, Martin; Lichtnecker, Herbert; Lob-Corzilius, Thomas; Merget, Rolf; Mülleneisen, Norbert; Nowak, Dennis; Rabe, Uta; Raulf, Monika; Seidl, Hans Peter; Steiß, Jens-Oliver; Szewszyk, Regine; Thomas, Peter; Valtanen, Kerttu; Wiesmüller, Gerhard A

    2017-04-01

    /or impairment of well-being. Predisposing factors for odor effects can be given by genetic and hormonal influences, imprinting, context and adaptation effects. Predisposing factors for impairment of well-being are environmental concerns, anxieties, conditioning and attributions as well as a variety of diseases. Risk groups that must be protected are patients with immunosuppression and with mucoviscidosis (cystic fibrosis) with regard to infections and individuals with mucoviscidosis and asthma with regard to allergies. If an association between mold exposure and health effects is suspected, the medical diagnosis includes medical history, physical examination, conventional allergy diagnosis, and if indicated, provocation tests. For the treatment of mold infections, it is referred to the AWMF guidelines for diagnosis and treatment of invasive Aspergillus infections. Regarding mycotoxins, there are currently no validated test methods that could be used in clinical diagnostics. From the perspective of preventive medicine, it is important that mold damages cannot be tolerated in indoor environments. Copyright © 2016 Elsevier GmbH. All rights reserved.

  7. Risk factors of indoor fall injuries in community-dwelling older women: a prospective cohort study.

    Science.gov (United States)

    Hu, Jia; Xia, Qinghua; Jiang, Yu; Zhou, Peng; Li, Yuhua

    2015-01-01

    The aims of the study were to explore the characteristics and the potential risk factors of indoor fall injuries in community-dwelling older women, and to provide evidence for the future intervention strategy. A prospective cohort of 3043 women aged 60 years old and above from 3 selected counties in Shanghai was followed up on the outcomes of indoor fall injuries for up to 1 year. Demographic and health data were collected during admission; the physical function, balance ability and home-living environment were examined by a structured questionnaire when admitted. The outcome of indoor fall injury was investigated by a visit in month 3, month 6 and month 12 after baseline survey. Univariate analysis and Multiple Logistic Regression Model were used to examine the associations between potential risk factors and outcomes of indoor fall injuries. Two hundred and thirty-one of the 3043 women (7.6%) eventually suffered indoor fall injuries at least once during the 1-year follow-up. The injurious falls of women were significantly associated with age, educational level, marital status, health status, balance ability, physical activity and home-living environment in the univariate analyses. Women who worried about falls and restrained activities for it were more likely to suffer fall injury. Younger women, with less chronic disease, with good balance ability and living in good corridor environment, were less likely to receive fall injury in multiple logistic regression analyses. Multidimensional factors were associated with indoor fall injuries for community-dwelling older women. Proper clinical treatment of chronic disease and improvement of women's balance ability, as well as reducing the risk factor of indoor environment, which will play vital roles in preventing indoor fall injuries, should be prioritized for the intervention strategy. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Bio-environmental factors associated with myopia: An updated review.

    Science.gov (United States)

    Galvis, V; Tello, A; Camacho, P A; Parra, M M; Merayo-Lloves, J

    2017-07-01

    Experimental studies in animals, as well as observational and intervention studies in humans, seem to support the premise that the development of juvenile myopia is promoted by a combination of the effect of genetic and environmental factors, with a complex interaction between them. The very rapid increase in myopia rates in some parts of the world, such as Southeast Asia, supports a significant environmental effect. Several lines of evidence suggest that humans might respond to various external factors, such as increased activity in near vision, increased educational pressure, decreased exposure to sunlight outdoors, dietary changes (including increased intake of carbohydrates), as well as low light levels indoors. All these factors could be associated with a higher prevalence of myopia. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Indoor air: Reference bibliography

    International Nuclear Information System (INIS)

    Campbell, D.; Staves, D.; McDonald, S.

    1989-07-01

    The U. S. Environmental Protection Agency initially established the indoor air Reference Bibliography in 1987 as an appendix to the Indoor Air Quality Implementation Plan. The document was submitted to Congress as required under Title IV--Radon Gas and Indoor Air Quality Research of the Superfund Amendments and Reauthorization Act of 1986. The Reference Bibliography is an extensive bibliography of reference materials on indoor air pollution. The Bibliography contains over 4500 citations and continues to increase as new articles appear

  10. Measurements of environmental radon - 222 concentrations in indoors and outdoors in Egypt

    International Nuclear Information System (INIS)

    Kenawy, M.A.; Morsey, A.A.; Kotb, M.A.; Osman, A.; El-Haag, A.

    1990-01-01

    The major contribution to population exposure from natural radiation arises from the inhalation of the decay products of radon. Substantial surveys are being conducted by several investigators to estimate the indoor and outdoor exposure nationally and to discover regional variations. In this work, radon concentration in the indoors and outdoor air was determined using the can technique and employing CR-39 solid state nuclear track detector for lengthy exposures. The range of radon - 222 activity in this survey was 54 -299 PCi.m -3 in Cairo, 22 - 171 PCi.m -3 in Alexandria and 89 - 370 PCi.m -3 in Asiut. Measurements carried out in Aswan and Sinai ranged between 98 - 411 PCi.m -3 . Values of indoors and outdoors radon concentrations were found to vary with time of day, geographic location, season and height above ground. Further work is going on to study the different parameters affecting the levels of the environmental radon. The national survey and associated studies is expected to yield data that may correlate radon activity with some respiratory diseases, particularly lung cancer. (author). 7 refs, 5 figs

  11. Real-time particle monitor calibration factors and PM2.5 emission factors for multiple indoor sources.

    Science.gov (United States)

    Dacunto, Philip J; Cheng, Kai-Chung; Acevedo-Bolton, Viviana; Jiang, Ruo-Ting; Klepeis, Neil E; Repace, James L; Ott, Wayne R; Hildemann, Lynn M

    2013-08-01

    Indoor sources can greatly contribute to personal exposure to particulate matter less than 2.5 μm in diameter (PM2.5). To accurately assess PM2.5 mass emission factors and concentrations, real-time particle monitors must be calibrated for individual sources. Sixty-six experiments were conducted with a common, real-time laser photometer (TSI SidePak™ Model AM510 Personal Aerosol Monitor) and a filter-based PM2.5 gravimetric sampler to quantify the monitor calibration factors (CFs), and to estimate emission factors for common indoor sources including cigarettes, incense, cooking, candles, and fireplaces. Calibration factors for these indoor sources were all significantly less than the factory-set CF of 1.0, ranging from 0.32 (cigarette smoke) to 0.70 (hamburger). Stick incense had a CF of 0.35, while fireplace emissions ranged from 0.44-0.47. Cooking source CFs ranged from 0.41 (fried bacon) to 0.65-0.70 (fried pork chops, salmon, and hamburger). The CFs of combined sources (e.g., cooking and cigarette emissions mixed) were linear combinations of the CFs of the component sources. The highest PM2.5 emission factors per time period were from burned foods and fireplaces (15-16 mg min(-1)), and the lowest from cooking foods such as pizza and ground beef (0.1-0.2 mg min(-1)).

  12. Indoor Air Quality in Schools

    Science.gov (United States)

    This web site will educate the public about indoor environmental issues specific to educational facilities and the importance of developing and sustaining comprehensive indoor air quality management programs.

  13. Satisfaction and self-estimated performance in relation to indoor environmental parameters and building features

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Frontczak, Monika; Schiavon, Stefano

    2012-01-01

    The paper examines how satisfaction with indoor environmental parameters and building features affects satisfaction and self-estimated job performance. The analyses used subjective responses from around 50, 000 occupants collected mainly in US office buildings using a web-based survey administered...

  14. Do indoor environments influence asthma and asthma-related symptoms among adults in homes? A review of the literature

    Directory of Open Access Journals (Sweden)

    Yu Jie

    2011-09-01

    Full Text Available This review summarizes the results of epidemiological studies focusing on the detrimental effects of home environmental factors on asthma morbidity in adults. We reviewed the literature on indoor air quality (IAQ, physical and sociodemographic factors, and asthma morbidity in homes, and identified commonly reported asthma, allergic, and respiratory symptoms involving the home environment. Reported IAQ and asthma morbidity data strongly indicated positive associations between indoor air pollution and adverse health effects in most studies. Indoor factors most consistently associated with asthma and asthma-related symptoms in adults included fuel combustion, mold growth, and environmental tobacco smoke. Environmental exposure may increase an adult’s risk of developing asthma and also may increase the risk of asthma exacerbations. Evaluation of present IAQ levels, exposure characteristics, and the role of exposure to these factors in relation to asthma morbidity is important for improving our understanding, identifying the burden, and for developing and implementing interventions aimed at reducing asthma morbidity.

  15. Indoor concentrations of radon 222 and its daughters: sources, range, and environmental influences

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1985-04-01

    The author here reviews what is presently known about factors affecting indoor concentrations of radon 222 and its daughters. In US single-family homes, radon concentrations are found to average about 1.5 pCi/1, but substantially higher concentrations occur frequently: perhaps a million US homes have concentrations exceeding 8 pCi/1 (from which occupants receive radiation doses comparable to those now experienced by uranium miners). The major contributor to indoor radon is ordinary soil underlying homes, with this radon being transported indoors primarily by the slight depressurization that occurs toward the bottom of a house interior (due to indoor-outdoor temperature differences and winds). Water from underground sources contributes significantly in a minority of cases, primarily residences with private wells, with public water supplies contributing only a few percent of indoor radon, even when drawn from wells. The strong variability in indoor concentrations is associated primarily with variability in the amount of radon entering homes from these various sources, and secondarily with differences in ventilation rates. However, for a given entry rate, the ventilation rate is the key determinant of indoor concentrations. Human doses are also influenced strongly by the chemical behavior of the daughters (i.e., decay products of radon), and considerable progress has been made recently in investigating a major aspect of this behavior, i.e., the manner in which daughters attach to airborne particles, to walls, and - indeed - to the lining of the lung itself, where the key radiation dose occurs

  16. Indoor air quality

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Indoor Air Quality is rapidly becoming a major environmental concern because a significant amount of people spend a substantial amount of time in a variety of different indoor environments. Health effects from indoor pollutants fall into two categories: those that are experienced immediately after exposure and those that do not show up until years later. They are: radon, formaldehyde, asbestos, lead and household organic chemicals. The authors presented a source-by-source look at the most common indoor air pollutants, their potential health effects, and ways to reduce their levels in the home. There are three basic strategies to improve indoor air quality: one method is source control, another is through ventilation improvements, and the third is the utilization of some sort of mechanical device such as air cleaners

  17. Accumulative effects of indoor air pollution exposure on leukocyte telomere length among non-smokers.

    Science.gov (United States)

    Lin, Nan; Mu, Xinlin; Wang, Guilian; Ren, Yu'ang; Su, Shu; Li, Zhiwen; Wang, Bin; Tao, Shu

    2017-08-01

    Indoor air pollution is an important environmental factor that contributes to the burden of various diseases. Long-term exposure to ambient air pollution is associated with telomere shortening. However, the association between chronic indoor air pollution from household fuel combustion and leukocyte telomere length has not been studied. In our study, 137 cancer-free non-smokers were recruited. Their exposure levels to indoor air pollution from 1985 to 2014 were assessed using a face-to-face interview questionnaire, and leukocyte telomere length (LTL) was measured using a monochrome multiplex quantitative PCR method. Accumulative exposure to solid fuel usage for cooking was negatively correlated with LTL. The LTL of residents who were exposed to solid fuel combustion for three decades (LTL = 0.70 ± 0.17) was significantly shorter than that of other populations. In addition, education and occupation were related to both exposure to solid fuel and LTL. Sociodemographic factors may play a mediating role in the correlation between leukocyte telomere length and environmental exposure to indoor air pollution. In conclusion, long-term exposure to indoor air pollution may cause LTL dysfunction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Indoor air quality issues related to the acquisition of conservation in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Baechler, M.C.; Hadley, D.L.; Marseille, T.J.

    1990-09-01

    The quality of indoor air in commercial buildings is dependent on the complex interaction between sources of indoor pollutants, environmental factors within buildings such as temperature and humidity, the removal of air pollutants by air-cleaning devices, and the removal and dilution of pollutants from outside air. To the extent that energy conservation measures (ECMs) may affect a number of these factors, the relationship between ECMs and indoor air quality is difficult to predict. Energy conservation measures may affect pollutant levels in other ways. Conservation measures, such as caulking and insulation, may introduce sources of indoor pollutants. Measures that reduce mechanical ventilation may allow pollutants to build up inside structures. Finally, heating, ventilation, and air-conditioning (HVAC) systems may provide surface areas for the growth of biogenic agents, or may encourage the dissemination of pollutants throughout a building. Information about indoor air quality and ventilation in both new and existing commercial buildings is summarized in this report. Sick building syndrome and specific pollutants are discussed, as are broader issues such as ventilation, general mitigation techniques, and the interaction between energy conservation activities and indoor air quality. Pacific Northwest Laboratory (PNL) prepared this review to aid the Bonneville Power Administration (Bonneville) in its assessment of potential environmental effects resulting from conservation activities in commercial buildings. 76 refs., 2 figs., 19 tabs.

  19. An evaluation model for indoor environmental quality (IEQ) acceptance in residential buildings

    International Nuclear Information System (INIS)

    Lai, A.C.K.; Mui, K.W.; Wong, L.T.; Law, L.Y.

    2009-01-01

    The indoor environmental quality (IEQ) in residential buildings is examined from the prospect of an occupant's acceptance in four aspects: thermal comfort, indoor air quality, noise level and illumination level. Based on the evaluations by 125 occupants living in 32 typical residential apartments in Hong Kong, this study proposes empirical expressions to approximate the overall IEQ acceptance with respect to four contributors, namely operative temperature, carbon dioxide concentration, equivalent noise level and illumination level, via a multivariate logistic regression model. A range of IEQ acceptances for regular residential conditions is determined and the dependence of the predicted overall IEQ acceptance on the variations of the contributors is discussed. The proposed overall IEQ acceptance can be used as a quantitative assessment criterion for similar residential environments where an occupant's evaluation is expected. (author)

  20. Indoor Air Pollutant Exposure for Life Cycle Assessment: Regional Health Impact Factors for Households

    DEFF Research Database (Denmark)

    Rosenbaum, Ralph K.; Meijer, Arjen; Demou, Evangelia

    2015-01-01

    of magnitude, due to the variability of ventilation rate, building occupation, and volume. To compare health impacts as a result of indoor exposure with those from outdoor exposure, the indoor exposure characterization factors determined with the modified USEtox model were applied in a case study on cooking...

  1. Hierarchical modeling of indoor radon concentration: how much do geology and building factors matter?

    International Nuclear Information System (INIS)

    Borgoni, Riccardo; De Francesco, Davide; De Bartolo, Daniela; Tzavidis, Nikos

    2014-01-01

    Radon is a natural gas known to be the main contributor to natural background radiation exposure and only second to smoking as major leading cause of lung cancer. The main concern is in indoor environments where the gas tends to accumulate and can reach high concentrations. The primary contributor of this gas into the building is from the soil although architectonic characteristics, such as building materials, can largely affect concentration values. Understanding the factors affecting the concentration in dwellings and workplaces is important both in prevention, when the construction of a new building is being planned, and in mitigation when the amount of Radon detected inside a building is too high. In this paper we investigate how several factors, such as geologic typologies of the soil and a range of building characteristics, impact on indoor concentration focusing, in particular, on how concentration changes as a function of the floor level. Adopting a mixed effects model to account for the hierarchical nature of the data, we also quantify the extent to which such measurable factors manage to explain the variability of indoor radon concentration. - Highlights: • It is assessed how the variability of indoor radon concentration depends on buildings and lithologies. • The lithological component has been found less relevant than the building one. • Radon-prone lithologies have been identified. • The effect of the floor where the room is located has been estimated. • Indoor radon concentration have been predicted for different dwelling typologies

  2. Influence of User Behaviour on Indoor Environmental Quality and Heating Energy Consumptions in Danish Dwellings

    DEFF Research Database (Denmark)

    Fabi, Valentina; Andersen, Rune Korsholm; Corgnati, Stefano Paolo

    Models of occupants’ interactions with heating controls based on measurements were implemented in a simulation program. Simulation results were given as probability distributions of energy consumption and indoor environmental quality depending on user behaviour. Heating set-point behaviour of 13...

  3. [Indoor volatile organic compounds: concentrations, sources, variation factors].

    Science.gov (United States)

    Palot, A; Charpin-Kadouch, C; Ercoli, J; Charpin, D

    2008-06-01

    Volatile organic compounds (V.O.C.) are part of urban air pollution and are also generated indoors from cleaning and maintenance products. VOC measurements are, on average, 10 times higher within homes than outside. Results of the national survey led by the Observatoire National de la Qualité de l'Air Intérieur demonstrated that up to 25% of French homes have very high or high concentrations of VOC. Indoor levels depend mainly on indoor sources. Aldehydes are included in many everyday life products. VOC originate from various household decorating and cleaning products. Some products are less detrimental to the environment and health and have special labelling. Indoor VOC levels also depend on the rate of air exchange and on household characteristics such as indoor temperature and humidity, age of the building, presence of smokers, and communication with a garage. The public may participate in maintaining good indoor air quality and the authorities should also improve regulations. VOC are part of everyday air pollution. Their sources and concentrations should be better monitored.

  4. A Generalized Model for Indoor Location Estimation Using Environmental Sound from Human Activity Recognition

    Directory of Open Access Journals (Sweden)

    Carlos E. Galván-Tejada

    2018-02-01

    Full Text Available The indoor location of individuals is a key contextual variable for commercial and assisted location-based services and applications. Commercial centers and medical buildings (e.g., hospitals require location information of their users/patients to offer the services that are needed at the correct moment. Several approaches have been proposed to tackle this problem. In this paper, we present the development of an indoor location system which relies on the human activity recognition approach, using sound as an information source to infer the indoor location based on the contextual information of the activity that is realized at the moment. In this work, we analyze the sound information to estimate the location using the contextual information of the activity. A feature extraction approach to the sound signal is performed to feed a random forest algorithm in order to generate a model to estimate the location of the user. We evaluate the quality of the resulting model in terms of sensitivity and specificity for each location, and we also perform out-of-bag error estimation. Our experiments were carried out in five representative residential homes. Each home had four individual indoor rooms. Eleven activities (brewing coffee, cooking, eggs, taking a shower, etc. were performed to provide the contextual information. Experimental results show that developing an indoor location system (ILS that uses contextual information from human activities (identified with data provided from the environmental sound can achieve an estimation that is 95% correct.

  5. Factors controlling indoor radon levels. Annual report, June 1983-May 1984

    International Nuclear Information System (INIS)

    Harley, N.H.

    1984-01-01

    The factors which contribute to indoor radon levels were investigated. Soil moisture content appears to be such a factor and influences indoor radon levels in a subtle way. The single family dwelling studied here is a typical suburban home, with a full basement, two living levels and a full attic. Seasonal data for 1981 to 1983 are shown by hour (about 90 hours in each average) for the basement, first floor and outdoors. A twenty-five story, 225 apartment, high rise building has been under study for about the same time interval. The apartment has five rooms, and is on the 24th floor. Continuous monitors are located in a work room and outdoors on a terrace. Data are available from the summer of 1981. 2 references, 12 figures, 9 tables

  6. Healthy indoors : achieving healthy indoor environments in Canada : Final report

    International Nuclear Information System (INIS)

    Anon

    2002-01-01

    A large proportion of the lives of Canadians is spent indoors, whether in vehicles, restaurants, shopping malls, offices or houses. The health of people working and living in those indoor settings might be damaged a a result, despite best efforts. Indoor pollution has been identified as one of the most serious risks to human health, according to numerous leading authorities, among them the American Lung Association, the United States Environmental Protection Agency, the Canada Mortgage and Housing Corporation (CMHC). A large number of cancer deaths are attributed to indoor pollution each year in the United States, as well as respiratory health problems. A causal link between certain indoor exposures and the development and provocation of asthma was established recently in a report on asthma and indoor air quality published by the National Academy of Sciences/Institute of Medicine. Exposure to indoor pollutants has also resulted in thousands of children experiencing elevated blood lead levels. Not enough attention is paid in Canada to pollution in buildings by government agencies, corporations and other non-governmental organizations and citizens. Not much seems to have changed in the past thirty years. An ambitious strategy by Pollution Probe was described in this document, listing the initial goals and measures required to achieve those goals. The creation of Healthy Indoors Partnership (HIP) was proposed to regroup all the stakeholders under the same umbrella. refs., tabs

  7. Indoor air quality environmental information handbook: Building system characteristics

    International Nuclear Information System (INIS)

    1987-01-01

    This manual, the third in a series, focuses on residential building system characteristics and their effects on indoor air quality. The manual addresses: residential indoor air pollutants by source, indoor concentrations, health effects, source control and mitigation techniques, standards and guidelines; building system characteristics of air exchange, pollutant source strength, residence volume, site characteristics, structural design, construction, and operation, infiltration and ventilation system, building occupancy; and monitoring methods

  8. Measurements of VOC/SVOC emission factors from burning incenses in an environmental test chamber: influence of temperature, relative humidity, and air exchange rate.

    Science.gov (United States)

    Manoukian, A; Buiron, D; Temime-Roussel, B; Wortham, H; Quivet, E

    2016-04-01

    This study investigates the influence of three environmental indoor parameters (i.e., temperature, relative humidity, and air exchange rate) on the emission of 13 volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) during incense burning. Experiments have been carried out using an environmental test chamber. Statistical results from a classical two-level full factorial design highlight the predominant effect of ventilation on emission factors. The higher the ventilation, the higher the emission factor. Moreover, thanks to these results, an estimation of the concentration range for the compounds under study can be calculated and allows a quick look of indoor pollution induced by incense combustion. Carcinogenic substances (i.e., benzene, benzo(a)pyrene, and formaldehyde) produced from the incense combustion would be predicted in typical living indoors conditions to reach instantaneous concentration levels close to or higher than air quality exposure threshold values.

  9. NIAID, NIEHS, NHLBI, and MCAN Workshop Report: The indoor environment and childhood asthma-implications for home environmental intervention in asthma prevention and management.

    Science.gov (United States)

    Gold, Diane R; Adamkiewicz, Gary; Arshad, Syed Hasan; Celedón, Juan C; Chapman, Martin D; Chew, Ginger L; Cook, Donald N; Custovic, Adnan; Gehring, Ulrike; Gern, James E; Johnson, Christine C; Kennedy, Suzanne; Koutrakis, Petros; Leaderer, Brian; Mitchell, Herman; Litonjua, Augusto A; Mueller, Geoffrey A; O'Connor, George T; Ownby, Dennis; Phipatanakul, Wanda; Persky, Victoria; Perzanowski, Matthew S; Ramsey, Clare D; Salo, Päivi M; Schwaninger, Julie M; Sordillo, Joanne E; Spira, Avrum; Suglia, Shakira F; Togias, Alkis; Zeldin, Darryl C; Matsui, Elizabeth C

    2017-10-01

    Environmental exposures have been recognized as critical in the initiation and exacerbation of asthma, one of the most common chronic childhood diseases. The National Institute of Allergy and Infectious Diseases; National Institute of Environmental Health Sciences; National Heart, Lung, and Blood Institute; and Merck Childhood Asthma Network sponsored a joint workshop to discuss the current state of science with respect to the indoor environment and its effects on the development and morbidity of childhood asthma. The workshop included US and international experts with backgrounds in allergy/allergens, immunology, asthma, environmental health, environmental exposures and pollutants, epidemiology, public health, and bioinformatics. Workshop participants provided new insights into the biologic properties of indoor exposures, indoor exposure assessment, and exposure reduction techniques. This informed a primary focus of the workshop: to critically review trials and research relevant to the prevention or control of asthma through environmental intervention. The participants identified important limitations and gaps in scientific methodologies and knowledge and proposed and prioritized areas for future research. The group reviewed socioeconomic and structural challenges to changing environmental exposure and offered recommendations for creative study design to overcome these challenges in trials to improve asthma management. The recommendations of this workshop can serve as guidance for future research in the study of the indoor environment and on environmental interventions as they pertain to the prevention and management of asthma and airway allergies. Published by Elsevier Inc.

  10. Accumulative effects of indoor air pollution exposure on leukocyte telomere length among non-smokers

    International Nuclear Information System (INIS)

    Lin, Nan; Mu, Xinlin; Wang, Guilian; Ren, Yu'ang; Su, Shu; Li, Zhiwen; Wang, Bin; Tao, Shu

    2017-01-01

    Indoor air pollution is an important environmental factor that contributes to the burden of various diseases. Long-term exposure to ambient air pollution is associated with telomere shortening. However, the association between chronic indoor air pollution from household fuel combustion and leukocyte telomere length has not been studied. In our study, 137 cancer-free non-smokers were recruited. Their exposure levels to indoor air pollution from 1985 to 2014 were assessed using a face-to-face interview questionnaire, and leukocyte telomere length (LTL) was measured using a monochrome multiplex quantitative PCR method. Accumulative exposure to solid fuel usage for cooking was negatively correlated with LTL. The LTL of residents who were exposed to solid fuel combustion for three decades (LTL = 0.70 ± 0.17) was significantly shorter than that of other populations. In addition, education and occupation were related to both exposure to solid fuel and LTL. Sociodemographic factors may play a mediating role in the correlation between leukocyte telomere length and environmental exposure to indoor air pollution. In conclusion, long-term exposure to indoor air pollution may cause LTL dysfunction. - Highlights: • This is the first study to investigate a clear association between indoor air pollution and leukocyte telomere length. • Chronic exposure to household solid fuel combustion and leukocyte telomere length presented a negative correlation. • Shortest leukocyte telomere length belonged to population cooking for longest time. • Education and occupation were remarkably associated with leukocyte telomere length via relating with indoor air pollution. - Long-term exposure to household solid fuel combustion is negatively associated with LTL.

  11. Headache symptoms and indoor environmental parameters: Results from the EPA BASE study

    Directory of Open Access Journals (Sweden)

    Gretchen E Tietjen

    2012-01-01

    Full Text Available Objective: The objective of this investigation was to determine the prevalence of migraine and headache symptoms in a national sample of US office employees. Also, we explored the association of headache symptoms with indoor environmental parameters of the work place. Background: Sick building syndrome (SBS, which includes headache, is a common global phenomenon, but the underlying environmental cause is uncertain. Materials and Methods: We used data from the 1994-1998 US Environmental Protection Agency′s (EPA Building Assessment and Survey Evaluation, a cross-sectional study of workers employed in 100 public and private office buildings across 25 states. The study used a self-administered questionnaire to assess headache frequency and prevalence of self-reported physician-diagnosed (SRPD migraine. Indoor environmental parameters (IEP were collected per EPA protocol from each building over a 1-week period and included carbon dioxide, carbon monoxide, temperature, relative humidity, particulate matter, volatile organic compound, illuminance, and sound level. The standards of American Society of Heating, Refrigerating and Air Conditioning Engineers were used to categorize IEP as either within- or out-of-comfort range for human dwelling. These limits delineate whether a parameter value is safe for human dwelling. Out-of-comfort range IEPs are associated with SBS and other human diseases. SRPD migraine and headache frequency were the primary outcome measures of the study. Multivariate logistic regression analyses were employed for the purpose of assessing the association between the outcome variable and IEPs. Results: Of the 4326 participants, 66% were females and 60% were between 30 and 49 years. Headache frequency during the last 4 weeks was as follows: None in 31%, 1-3 days in 38%, 1-3 days per week in 18%, and every or almost every workday in 8%. Females had higher SRPD migraine prevalence compared to males (27% vs. 11%, P<0.001 and were more

  12. A contemporary method for monitoring indoor radon and environmental conditions at a remote test site

    International Nuclear Information System (INIS)

    Renken, K.J.; Coursin, S.

    1996-01-01

    A state-of-the-art method for automatically monitoring indoor radon and environmental conditions at a remote test site is described. A Wisconsin home that exhibited elevated radon levels has been installed with automated PC-data acquisition system (PC-DAS) that includes: a laptop PC, a data acquisition cardcage, a commercial data acquisition software program plus sensors to measure radon gas concentrations, differential pressures, indoor air quality and meteorological conditions. The isolated PC-DAS is connected to a PC in a university laboratory via a modem and a communications software package. Experimental data is monitored and saved by the remote PC in real time and then automatically downloaded to the lab computer at selected intervals. An example of the formatted field results is presented and analysed. This documentation of the set-up, the off-the-shelf computer hardware and software, and the procedures should assist investigations requiring flexible remote long-term radon and environmental monitoring. (Author)

  13. Office of radiation and indoor air: Program description

    International Nuclear Information System (INIS)

    1993-06-01

    The goal of the Environmental Protection Agency's (EPA) Office of Radiation and Indoor Air is to protect the public and the environment from exposures to radiation and indoor air pollutants. The Office develops protection criteria, standards, and policies and works with other programs within EPA and other agencies to control radiation and indoor air pollution exposures; provides technical assistance to states through EPA's regional offices and other agencies having radiation and indoor air protection programs; directs an environmental radiation monitoring program; responds to radiological emergencies; and evaluates and assesses the overall risk and impact of radiation and indoor air pollution. The Office is EPA's lead office for intra- and interagency activities coordinated through the Committee for Indoor Air Quality. It coordinates with and assists the Office of Enforcement in enforcement activities where EPA has jurisdiction. The Office disseminates information and works with state and local governments, industry and professional groups, and citizens to promote actions to reduce exposures to harmful levels of radiation and indoor air pollutants

  14. Influence of user behavior on unsatisfactory indoor thermal environment

    International Nuclear Information System (INIS)

    Yan, Biao; Long, Enshen; Meng, Xi; Zhang, Yuanze; Hou, Dongqi; Du, Xin

    2014-01-01

    Highlights: • The methodology of numerical simulation of 3D heat-flux visualization is proposed. • A full-scale model of prototype office for each influential factor was set up. • The simulation results were compared with the indoor occupant comfort levels. • The contrast of average temperature increase due to user behavior was presented. - Abstract: In areas of China that have hot summers and cold winters, the overall performance of HVAC systems in the poorly-insulated existing office buildings is generally not satisfactory, especially in extreme weather conditions. The reasons for the unsatisfactory indoor thermal environment were deduced, and to validate the findings, a methodology of numerical simulation for 3D heat-flux visualization was proposed. A full-scale model of a prototype office room was created, with representative working conditions for the characteristics of particular building. The results of the heat-flux visualization and temperature distribution showed that the overall effect was resulted from merged reasons, and that significance ranking of each reason varied when the outside environmental conditions changed. The simulation results were compared with the indoor occupant comfort levels of the volunteers who worked in the target room. Models of possible influential factors such as the outdoor temperature, opening or closing windows, and the effect of window shading devices (WSD) were set up. The influence of user behavior on indoor temperature in opening window, or not using WSD was proven to be significant in causing unfavorable indoor conditions. According to the visualized evaluation and analysis of the various factors, corresponding methods for both improving indoor thermal conditions and saving energy are proposed

  15. Environmental assessment of three egg production systems--Part I: Monitoring system and indoor air quality.

    Science.gov (United States)

    Zhao, Y; Shepherd, T A; Li, H; Xin, H

    2015-03-01

    To comprehensively assess conventional vs. some alternative laying-hen housing systems under U.S. production conditions, a multi-institute and multi-disciplinary project, known as the Coalition for Sustainable Egg Supply (CSES) study, was carried out at a commercial egg production farm in the Midwestern United States over two single-cycle production flocks. The housing systems studied include a conventional cage house (200,000 hen capacity), an aviary house (50,000 hen capacity), and an enriched colony house (50,000 hen capacity). As an integral part of the CSES project, continual environmental monitoring over a 27-month period described in this paper quantifies indoor gaseous and particulate matter concentrations, thermal environment, and building ventilation rate of each house. Results showed that similar indoor thermal environments in all three houses were maintained through ventilation management and environmental control. Gaseous and particulate matter concentrations of the enriched colony house were comparable with those of the conventional cage house. In comparison, the aviary house had poorer indoor air quality, especially in wintertime, resulting from the presence of floor litter (higher ammonia levels) and hens' activities (higher particulate matter levels) in it. Specifically, daily mean indoor ammonia concentrations had the 95% confidence interval values of 3.8 to 4.2 (overall mean of 4.0) ppm for the conventional cage house; 6.2 to 7.2 (overall mean of 6.7) ppm for the aviary house; and 2.7 to 3.0 (overall mean of 2.8) ppm for the enriched colony house. The 95% confidence interval (overall mean) values of daily mean indoor carbon dioxide concentrations were 1997 to 2170 (2083) ppm for the conventional cage house, 2367 to 2582 (2475) ppm for the aviary house, and 2124 to 2309 (2216) ppm for the enriched colony house. Daily mean indoor methane concentrations were similar for all three houses, with 95% confidence interval values of 11.1 to 11.9 (overall

  16. Environmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality

    Science.gov (United States)

    Zhao, Y.; Shepherd, T. A.; Li, H.; Xin, H.

    2015-01-01

    To comprehensively assess conventional vs. some alternative laying-hen housing systems under U.S. production conditions, a multi-institute and multi-disciplinary project, known as the Coalition for Sustainable Egg Supply (CSES) study, was carried out at a commercial egg production farm in the Midwestern United States over two single-cycle production flocks. The housing systems studied include a conventional cage house (200,000 hen capacity), an aviary house (50,000 hen capacity), and an enriched colony house (50,000 hen capacity). As an integral part of the CSES project, continual environmental monitoring over a 27-month period described in this paper quantifies indoor gaseous and particulate matter concentrations, thermal environment, and building ventilation rate of each house. Results showed that similar indoor thermal environments in all three houses were maintained through ventilation management and environmental control. Gaseous and particulate matter concentrations of the enriched colony house were comparable with those of the conventional cage house. In comparison, the aviary house had poorer indoor air quality, especially in wintertime, resulting from the presence of floor litter (higher ammonia levels) and hens’ activities (higher particulate matter levels) in it. Specifically, daily mean indoor ammonia concentrations had the 95% confidence interval values of 3.8 to 4.2 (overall mean of 4.0) ppm for the conventional cage house; 6.2 to 7.2 (overall mean of 6.7) ppm for the aviary house; and 2.7 to 3.0 (overall mean of 2.8) ppm for the enriched colony house. The 95% confidence interval (overall mean) values of daily mean indoor carbon dioxide concentrations were 1997 to 2170 (2083) ppm for the conventional cage house, 2367 to 2582 (2475) ppm for the aviary house, and 2124 to 2309 (2216) ppm for the enriched colony house. Daily mean indoor methane concentrations were similar for all three houses, with 95% confidence interval values of 11.1 to 11.9 (overall

  17. The effect of the indoor environment on the fate of organic chemicals in the urban landscape

    International Nuclear Information System (INIS)

    Cousins, Anna Palm

    2012-01-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical–chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK OA and the impact of the ventilation rate on the urban fate of organic chemicals. -- Highlights: ► A novel indoor-inclusive multimedia urban fate model is developed and applied. ► Emissions indoors may increase the urban chemical residence time. ► Indoor removal from surfaces constitutes an additional loss process

  18. Analytical solutions to compartmental indoor air quality models with application to environmental tobacco smoke concentrations measured in a house.

    Science.gov (United States)

    Ott, Wayne R; Klepeis, Neil E; Switzer, Paul

    2003-08-01

    This paper derives the analytical solutions to multi-compartment indoor air quality models for predicting indoor air pollutant concentrations in the home and evaluates the solutions using experimental measurements in the rooms of a single-story residence. The model uses Laplace transform methods to solve the mass balance equations for two interconnected compartments, obtaining analytical solutions that can be applied without a computer. Environmental tobacco smoke (ETS) sources such as the cigarette typically emit pollutants for relatively short times (7-11 min) and are represented mathematically by a "rectangular" source emission time function, or approximated by a short-duration source called an "impulse" time function. Other time-varying indoor sources also can be represented by Laplace transforms. The two-compartment model is more complicated than the single-compartment model and has more parameters, including the cigarette or combustion source emission rate as a function of time, room volumes, compartmental air change rates, and interzonal air flow factors expressed as dimensionless ratios. This paper provides analytical solutions for the impulse, step (Heaviside), and rectangular source emission time functions. It evaluates the indoor model in an unoccupied two-bedroom home using cigars and cigarettes as sources with continuous measurements of carbon monoxide (CO), respirable suspended particles (RSP), and particulate polycyclic aromatic hydrocarbons (PPAH). Fine particle mass concentrations (RSP or PM3.5) are measured using real-time monitors. In our experiments, simultaneous measurements of concentrations at three heights in a bedroom confirm an important assumption of the model-spatial uniformity of mixing. The parameter values of the two-compartment model were obtained using a "grid search" optimization method, and the predicted solutions agreed well with the measured concentration time series in the rooms of the home. The door and window positions in

  19. Determining size-specific emission factors for environmental tobacco smoke particles

    Energy Technology Data Exchange (ETDEWEB)

    Klepeis, Neil E.; Apte, Michael G.; Gundel, Lara A.; Sextro, Richard G.; Nazaroff, William W.

    2002-07-07

    Because size is a major controlling factor for indoor airborne particle behavior, human particle exposure assessments will benefit from improved knowledge of size-specific particle emissions. We report a method of inferring size-specific mass emission factors for indoor sources that makes use of an indoor aerosol dynamics model, measured particle concentration time series data, and an optimization routine. This approach provides--in addition to estimates of the emissions size distribution and integrated emission factors--estimates of deposition rate, an enhanced understanding of particle dynamics, and information about model performance. We applied the method to size-specific environmental tobacco smoke (ETS) particle concentrations measured every minute with an 8-channel optical particle counter (PMS-LASAIR; 0.1-2+ micrometer diameters) and every 10 or 30 min with a 34-channel differential mobility particle sizer (TSI-DMPS; 0.01-1+ micrometer diameters) after a single cigarette or cigar was machine-smoked inside a low air-exchange-rate 20 m{sup 3} chamber. The aerosol dynamics model provided good fits to observed concentrations when using optimized values of mass emission rate and deposition rate for each particle size range as input. Small discrepancies observed in the first 1-2 hours after smoking are likely due to the effect of particle evaporation, a process neglected by the model. Size-specific ETS particle emission factors were fit with log-normal distributions, yielding an average mass median diameter of 0.2 micrometers and an average geometric standard deviation of 2.3 with no systematic differences between cigars and cigarettes. The equivalent total particle emission rate, obtained integrating each size distribution, was 0.2-0.7 mg/min for cigars and 0.7-0.9 mg/min for cigarettes.

  20. International Performance Measurement & Verification Protocol: Concepts and Practices for Improved Indoor Environmental Quality, Volume II (Revised)

    Energy Technology Data Exchange (ETDEWEB)

    2002-03-01

    This protocol serves as a framework to determine energy and water savings resulting from the implementation of an energy efficiency program. It is also intended to help monitor the performance of renewable energy systems and to enhance indoor environmental quality in buildings.

  1. Indoor Residential Chemical Exposures as Risk Factors for Asthmaand Allergy in Infants and Children: a Review

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.

    2006-03-01

    Most research into effects of residential indoor air exposures on asthma and allergies has focused on exposures to biologic allergens, moisture and mold, endotoxin, or combustion byproducts. This paper briefly reviews reported findings on associations of asthma or allergy in infants or children with risk factors related to indoor chemical emissions from residential materials or surface coatings. Associations, some strong (e.g., odds ratios up to 13), were reported. The most frequently identified risk factors were formaldehyde, aromatic organic compounds such as toluene and benzene, plastic materials and plasticizers, and recent painting. Exposures and consequent effects from indoor sources may be exacerbated by decreased ventilation. Identified risk factors may be proxies for correlated exposures. Findings suggest the frequent occurrence of important but preventable effects on asthma and allergy in infants and children worldwide from modern residential building materials and coatings.

  2. External eye symptoms in indoor environments.

    Science.gov (United States)

    Wolkoff, P

    2017-03-01

    Eye irritation, for example dry or irritated eyes, is generally among top three reported symptoms in office-like environments, in particular among workplaces with cognitive demanding visual display unit (VDU) work. The symptoms are especially among middle and advanced ages and particularly among women more than men. The symptoms are also among the most commonly reported complaints in the eye clinic. To be in a position to interpret the high prevalence of eye symptoms, a multidisciplinary and integrated approach is necessary that involves the external eye physiology (separate from internal eye effects), eye diseases (evaporative dry eye (DE), aqueous-deficient DE, and gland dysfunctions), and risk factors that aggravate the stability of precorneal tear film (PTF) resulting in hyperosmolarity and initiation of inflammatory reactions. Indoor environmental, occupational and personal risk factors may aggravate the PTF stability; factors such as age, contact lenses, cosmetics, diet, draft, gender, low humidity and high temperature, medication, outdoor and combustion pollutants, and VDU work. Psychological stressors may further influence the reporting behavior of eye symptoms. The impact of the risk factors may occur in a combined and exacerbating manner. © 2016 The Authors. Indoor Air published by John Wiley & Sons Ltd.

  3. Association between Four-Level Categorisation of Indoor Exposure and Perceived Indoor Air Quality

    Directory of Open Access Journals (Sweden)

    Katja Tähtinen

    2018-04-01

    Full Text Available The aim of this study was to develop and test a tool for assessing urgency of indoor air quality (IAQ measures. The condition of the 27 buildings were investigated and results were categorized. Statistical test studied the differences between the categories and the employees’ complaints about their work environment. To study the employees’ experiences of the work premises, a validated indoor air (IA questionnaire was used. This study reveals a multifaceted problem: many factors affecting IAQ may also affect perceived IAQ, making it difficult to separate the impurity sources and ventilation system deficiencies affecting to employee experiences. An examination of the relationship between the categories and perceived IAQ revealed an association between the mould odour perceived by employees and mould detected by the researcher. A weak link was also found between the assessed categories and environmental complaints. However, we cannot make far-reaching conclusions regarding the assessed probability of abnormal IA exposure in the building on the basis of employee experiences. According to the results, categorising tool can partly support the assessment of the urgency for repairs when several factors that affect IAQ are taken into account.

  4. Association between Four-Level Categorisation of Indoor Exposure and Perceived Indoor Air Quality.

    Science.gov (United States)

    Tähtinen, Katja; Lappalainen, Sanna; Karvala, Kirsi; Remes, Jouko; Salonen, Heidi

    2018-04-04

    The aim of this study was to develop and test a tool for assessing urgency of indoor air quality (IAQ) measures. The condition of the 27 buildings were investigated and results were categorized. Statistical test studied the differences between the categories and the employees’ complaints about their work environment. To study the employees’ experiences of the work premises, a validated indoor air (IA) questionnaire was used. This study reveals a multifaceted problem: many factors affecting IAQ may also affect perceived IAQ, making it difficult to separate the impurity sources and ventilation system deficiencies affecting to employee experiences. An examination of the relationship between the categories and perceived IAQ revealed an association between the mould odour perceived by employees and mould detected by the researcher. A weak link was also found between the assessed categories and environmental complaints. However, we cannot make far-reaching conclusions regarding the assessed probability of abnormal IA exposure in the building on the basis of employee experiences. According to the results, categorising tool can partly support the assessment of the urgency for repairs when several factors that affect IAQ are taken into account.

  5. Monitoring Indoor Air Quality for Enhanced Occupational Health.

    Science.gov (United States)

    Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque

    2017-02-01

    Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of non-specific symptoms which characterizes the "Sick Building Syndrome", involving the skin, the upper and lower respiratory tract, the eyes and the nervous system, as well as many building related diseases. Thus, indoor air quality (IAQ) is recognized as an important factor to be controlled for the occupants' health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This work describes the system (iAQ), a low-cost indoor air quality monitoring wireless sensor network system, developed using Arduino, XBee modules and micro sensors, for storage and availability of monitoring data on a web portal in real time. Five micro sensors of environmental parameters (air temperature, humidity, carbon monoxide, carbon dioxide and luminosity) were used. Other sensors can be added for monitoring specific pollutants. The results reveal that the system can provide an effective indoor air quality assessment to prevent exposure risk. In fact, the indoor air quality may be extremely different compared to what is expected for a quality living environment. Systems like this would have benefit as public health interventions to reduce the burden of symptoms and diseases related to "sick buildings".

  6. Hierarchical modeling of indoor radon concentration: how much do geology and building factors matter?

    Science.gov (United States)

    Borgoni, Riccardo; De Francesco, Davide; De Bartolo, Daniela; Tzavidis, Nikos

    2014-12-01

    Radon is a natural gas known to be the main contributor to natural background radiation exposure and only second to smoking as major leading cause of lung cancer. The main concern is in indoor environments where the gas tends to accumulate and can reach high concentrations. The primary contributor of this gas into the building is from the soil although architectonic characteristics, such as building materials, can largely affect concentration values. Understanding the factors affecting the concentration in dwellings and workplaces is important both in prevention, when the construction of a new building is being planned, and in mitigation when the amount of Radon detected inside a building is too high. In this paper we investigate how several factors, such as geologic typologies of the soil and a range of building characteristics, impact on indoor concentration focusing, in particular, on how concentration changes as a function of the floor level. Adopting a mixed effects model to account for the hierarchical nature of the data, we also quantify the extent to which such measurable factors manage to explain the variability of indoor radon concentration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Indoor Thermal Environment in Tropical Climate Residential Building

    Directory of Open Access Journals (Sweden)

    Jamaludin Nazhatulzalkis

    2014-01-01

    Full Text Available Indoor thermal environment is one of the criteria in sustainable building. This criterion is important in ensuring a healthy indoor environment for the occupants. The consideration of environmental concerns at the early design stage would effectively integrate the sustainability of the building environment. Global climate changes such as global warming do affect human comfort since people spend most of their time and activities in the building. The increasing of urban population required additional housing for households, as well as places to shop, office and other facilities. Occupants are now more conscious the importance of sustainability for a better quality of life. Good thermal environment is essential for human wellness and comfort. A residential environment will influence residents’ health and safety. The global warming increase the earth’s temperature and greenhouse emission to the atmosphere cause adverse effects to the outdoor environment. Residential developments modify the materials, structure and energy balance in urban climate effects of human economic activities. As an indoor environment is influenced by the outdoor condition, the factors affecting indoor thermal environment are crucial in improving a comfortable and healthy environment in residential building. The microclimatic of a site such as temperature and relative humidity, and wind movement led to the variation of indoor thermal environment in the building.

  8. Indoor air. Seminar of Zentrale Informationsstelle, Umweltberatung Bayern. Vol. 2

    International Nuclear Information System (INIS)

    Koller, U.; Haury, H.J.

    1994-02-01

    This seminar dealt with the subject of indoor air pollution and welcomed participants from environmental consultancy agencies and authorities and institutions related with environmental protection. Leading scientists from research and authorities presented the current state of knowledge abut the risks of indoorair pollution. The papers contained in these proceedings addressed: room climate and sick-building syndrome; allergens in indoor spaces; pollutants emitted by exemplary building materials; pollutant levels of organic compounds in indoor spaces; air quality in motor vehicle interiors; indoor air pollution - risk assessment and need for actions. (Uhe) [de

  9. [Real-time measurement of indoor particulate matter originating from environmental tobacco smoke: a pilot study].

    Science.gov (United States)

    Invernizzi, Giovanni; Ruprecht, Ario; Mazza, Roberto; Majno, Edoardo; Rossetti, Edoardo; Paredi, Paolo; Boffi, Roberto

    2002-01-01

    Short-term measurement of suspended particulate matter has been recently made possible since the release of laser-operating portable instruments. Data of a pilot study of field evaluation of environmental tobacco smoke (ETS) with a portable instrument are reported. We analysed the concentrations of total suspended particle (TSP) and of the fine particles PM10, PM7, PM2.5 and PM1 released indoor from a single cigarette, and their levels inside smoking- and non-smoking-areas of a restaurant. The results indicate that ETS creates high level indoor particulate pollution, with concentrations of PM10 exceeding air quality standards. This kind of field evaluation could allow a more careful assessing of short-term exposure to ETS and its relevance to public health.

  10. The effect of the indoor environment on the fate of organic chemicals in the urban landscape

    Energy Technology Data Exchange (ETDEWEB)

    Cousins, Anna Palm, E-mail: anna.cousins@ivl.se

    2012-11-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical-chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK{sub OA} and the impact of the ventilation rate on the urban fate of organic chemicals. -- Highlights: Black-Right-Pointing-Pointer A novel indoor-inclusive multimedia urban fate model is developed and applied. Black-Right-Pointing-Pointer Emissions indoors may increase the urban chemical residence time. Black

  11. Air-Sense: indoor environment monitoring evaluation system based on ZigBee network

    Science.gov (United States)

    Huang, Yang; Hu, Liang; Yang, Disheng; Liu, Hengchang

    2017-08-01

    In the modern life, people spend most of their time indoors. However, indoor environmental quality problems have always been affecting people’s social activities. In general, indoor environmental quality is also related to our indoor activities. Since most of the organic irritants and volatile gases are colorless, odorless and too tiny to be seen, because we have been unconsciously overlooked indoor environment quality. Consequently, our body suffer a great health problem. In this work, we propose Air-Sense system which utilizes the platform of ZigBee Network to collect and detect the real-time indoor environment quality. What’s more, Air-Sense system can also provide data analysis, and visualizing the results of the indoor environment to the user.

  12. Indoor air quality in low-energy houses in the Netherlands: Does mechanical ventilation provide a healthy indoor environment?

    NARCIS (Netherlands)

    Balvers, J.R.; Boxem, G.; Wit, de M.H.; Strøm-Tejsen, P; Olesen, B.W.; Wargocki, P; Zukowska, D; Toftum, J

    2008-01-01

    Increasing environmental awareness has led to new, energy-efficient building standards such as the German Passivhaus-standard. This study was designed to investigate the indoor air quality (IAQ) of four different Dutch low-energy houses built according to this standard. Air flow, indoor air

  13. Energy and indoor environmental quality in relocatable classrooms

    International Nuclear Information System (INIS)

    Apte, Michael; Hodgson, Alfred; Shendell, Derek; Dibartolomeo, Dennis; Hochi, Toshifumi; Kumar, Satish; Lee, Seung-Min; Liff, Shawna; Rainer, Leo; Schmidt, Richard; Sullivan, Douglas; Diamond, Richard; Fisk, William

    2002-01-01

    Relocatable classrooms (RCs) are commonly utilized by school districts with changing demographics and enrollment sizes. Four energy-efficient RCs were designed and constructed for this study to demonstrate technologies that simultaneously attempt to improve energy efficiency and indoor environmental quality (IEQ). Two were installed at each of two school districts, and energy use and IEQ parameters were monitored during occupancy. Two (one per school) were finished with materials selected for reduced emissions of toxic and odorous volatile organic compounds (VOCs). Each RC had two HVAC systems, alternated weekly, consisting of a standard heat-pump system and an indirect-direct evaporative cooling (IDEC) system with gas-fired hydronic heating. The hypothesized advantages of the IDEC include continuous outside air ventilation at(ge)7.5 L s(sup -1) per person,(approx)70% less cooling energy and efficient particle filtration. Measurements include: carbon dioxide, particles, VOCs, temperature, humidity, thermal comfort, noise, meteorology, and energy use. Preliminary IEQ monitoring results are reported

  14. Validation of Environmental Stress Index by Measuring Infrared Radiation as a Substitute for Solar Radiation in Indoor Workplaces

    Directory of Open Access Journals (Sweden)

    Peymaneh Habibi

    2016-09-01

    Full Text Available Background The exposure of individuals to heat at different jobs warrants the use of heat stress evaluation indices. Objectives The aim of this study was to validate environmental stress index using an infrared radiation (IR measurement instrument as a substitute for pyranometer in indoor workplaces. Methods This study was conducted on 2303 indoor workstations in different industries in Isfahan, Iran, during July, August, and September in 2012. The intensity of the Infrared Radiation (IR (w/m2 was measured at five-centimeter distances in six different directions, above, opposite, right, left, behind and below the globe thermometer. Then, the dry globe temperature (Ta, wet globe temperature (Tnw, globe temperature (Tg and relative humidity (RH were also simultaneously measured. The data were analyzed using correlation and regression by the SPSS18 software. Results The study results indicate that a high correlation (r = 0.96 exists between the environmental stress index (ESI and the values of wet bulb globe temperature (P < 0.01. According to the following equation, WBGT = 1.086 × ESI - 1.846, the environmental stress index is able to explain 91% (R2 = 0.91 of the WBGT index variations (P < 0.01. Conclusions Based on the results, to study heat stress in indoor workplaces when the WBGT measurement instrument is not available and also in short-term exposures (shorter than 30 minutes when measuring the wet bulb globe temperature shows a considerable error, it is possible to calculate the environmental stress index and accordingly to the WBGT index, by measuring the parameters of dry bulb temperature (Ta, relative humidity (RH, and infrared radiation intensity that can be easily measured in a short time.

  15. An Evaluation of Early Education Based on Physical Environmental Guidelines

    Directory of Open Access Journals (Sweden)

    Donna J. Satterlee

    2015-05-01

    Full Text Available The integration of environmental policies with political support for action on these policies is of prime significance for mobilization and progression of improving indoor environments. However, state licensing agencies and local county ordinances for child care centers do not universally follow these policies and standards. As a result, most early childhood educational programs operate without proper indoor environments. Indoor air quality, temperature, ventilation, daylighting, and acoustics are crucial factors for educational settings in early childhood education. This study documents the physical environment in early childhood education centers in three counties in Maryland. Results indicate that building performance and indoor air quality standards vary according to the socioeconomic status of children who attend early childhood programs, and environmental factors correlate with educational achievement (as measured by kindergarten readiness scores.

  16. An energy performance assessment for indoor environmental quality (IEQ) acceptance in air-conditioned offices

    International Nuclear Information System (INIS)

    Wong, L.T.; Mui, K.W.

    2009-01-01

    Maintaining an acceptable indoor environmental quality (IEQ) for air-conditioned office buildings consumes a considerable amount of thermal energy. This study correlates thermal energy consumption with the overall occupant acceptance of IEQ in some air-conditioned offices. An empirical expression of an IEQ index associated with thermal comfort, indoor air quality, aural and visual comfort is used to benchmark the offices. Employing input parameters obtained from the building stocks of Hong Kong, the office portfolios regarding the thermal energy consumption and the IEQ index are determined by Monte Carlo simulations. In particular, an energy-to-acceptance ratio and an energy-to-IEQ improvement ratio are proposed to measure the performance of energy consumption for the IEQ in the air-conditioned offices. The ratios give the thermal energy consumption corresponding to a desirable percentage of IEQ acceptances and to an IEQ upgrade, respectively. The results showed a non-linear increasing trend of annual thermal energy consumption for IEQ improvement at the offices of higher IEQ benchmarks. The thermal energy consumption for visual comfort and indoor air quality would also be significant in these offices. This study provides useful information that incorporates the IEQ in air-conditioned offices into the development of performance evaluation measures for thermal energy consumption.

  17. Indoor Tanning Dependence in Young Adult Women.

    Science.gov (United States)

    Mays, Darren; Atkins, Michael B; Ahn, Jaeil; Tercyak, Kenneth P

    2017-11-01

    Background: There is mounting evidence that young people can develop a dependence on indoor tanning, but research on factors associated with indoor tanning dependence remains limited. Methods: This cross-sectional study investigated factors associated with indoor tanning dependence in a community sample of 389 non-Hispanic white young adult women ages 18 to 30 who had indoor tanned ≥1 time in the past year. Participants completed measures of indoor tanning dependence, including the modified CAGE and modified Diagnostic and Statistical Manual for Mental Disorders-IV psychiatric screening assessments, indoor tanning behavior and beliefs, and behavioral and psychiatric comorbidity. Results: Overall, 22.6% of the sample screened positive for indoor tanning dependence. In multivariable analyses, indoor tanning dependence was associated with younger age of indoor tanning initiation [adjusted odds ratio (aOR) = 0.79; P = 0.017], indoor tanning ≥20 times in the past year (aOR = 3.03; P = 0.015), stronger beliefs about the benefits of tanning (aOR = 2.15; P = 0.004), greater perceived susceptibility to indoor tanning risks (aOR = 2.72; P tanning dependence among young, non-Hispanic white women is associated with behaviors that increase the risk of skin cancer, beliefs favoring the perceived benefits of tanning, and comorbid risks such as stronger beliefs about physical appearance and depressed mood. Impact: Comprehensive skin cancer prevention efforts should address indoor tanning dependence among young women and its leading risk factors. Cancer Epidemiol Biomarkers Prev; 26(11); 1636-43. ©2017 AACR . ©2017 American Association for Cancer Research.

  18. A study of some factors which are related to indoor radon concentrations in Greece

    International Nuclear Information System (INIS)

    Louizi, A.; Nikolopoulos, D.; Lobotesi, E.; Mavroudaki, E.; Koukouliou, V.K.; Chanioti, M.; Papadimitriou, D.; Yiakoumakis, M.; Proukakis, C.

    1997-01-01

    The Medical Physics Department of the University of Athens is conducting radon-222 measurements in Greek dwellings. It is well known that the concentration of radon gas indoors, are related to various factors. A study of these factors has started and first results are reported. (authors)

  19. A holistic approach for the assessment of the indoor environmental quality, student productivity, and energy consumption in primary schools.

    Science.gov (United States)

    Dorizas, Paraskevi Vivian; Assimakopoulos, Margarita-Niki; Santamouris, Mattheos

    2015-05-01

    The perception of the indoor environmental quality (IEQ) through questionnaires in conjunction with in-field measurements related to the indoor air quality (IAQ), the thermal comfort and the lighting environment were studied in nine naturally ventilated schools of Athens, Greece. Cluster analysis was carried out in order to determine the ranges of indoor air pollutants, temperature (T), relative humidity (RH), and ventilation rates at which the students were satisfied with the indoor environment. It was found that increased levels of particulate matter did not have a negative effect on students' perception while students seemed to link the degradation of IAQ with temperature variations. Statistically significant correlations were further found between measurement results and students' perception of the IEQ. Students' sick building syndrome (SBS) symptoms and performance of schoolwork were also investigated as a function of the levels of indoor air pollutants and ventilation, and there were found significant positive correlations between particulate matter (PM) and certain health symptoms. Students' learning performance seemed to be affected by the ventilation rates and carbon dioxide (CO₂) concentrations while certain health effects positively correlated to the levels of PM and CO₂. The energy consumption of schools was rather low compared to other national findings, and both the electricity and oil consumption for heating positively correlated to the levels of indoor air pollutants.

  20. Vitality of plants to live in the indoor environment

    Science.gov (United States)

    Shamsuri, Mohd Mahathir Suhaimi; Leman, A. M.; Hariri, Azian; Idris, Ahmad Fu'ad; Afandi, Azizi

    2017-09-01

    Indoor air quality (IAQ) is generally a public concern because 90% of people spend their time indoor. IAQ must be preserved wisely to guarantee the health of the building occupants. One of the ways to maintain the quality of air is by placing plants in the building. However, all plants come from the outdoor, and the environment is different compared to indoor. Environmental factors such as temperature and light will absolutely affect the growth of the plant. Light and temperature that are too bright or too deem can wither the plants. Nevertheless, certain plant is capable of adapting with different situation after assimilation process has been conducted. This study intends to analyze the capacity of seven selected plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium) to live in an indoor environment. The vitality of plants is based on photosynthetic level that is measured using leaf - chamber (LI-COR 6400). Two groups of plants were located in indoor and outdoor (indigenous location) setting, and were allowed to assimilate for two months before measurement were carried out. The results for the plant located indoor shows that only Spider Plant cannot perform photosynthesis under 300 lux, where the photosynthetic value remains negative. Meanwhile, other plants such as Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, and Syngonium that were left indoor showed similar 300 lux in which conform the ability of the plants to perform photosynthesis with the value of 0.3, 0.15, 0.35, 0.1, 0.15, and 0.1. In comparison, all of the plants that were stationed indoor and outdoor (except Spider Plant), the light compensation point (LCP) for indoor shows smaller value than the outdoor. This is because all the indoor plants had down - regulated their photosynthesis process by becoming more sensitive to light after their assimilation. From this study, it can be concluded that all plants except Spider Plant is able to live

  1. Indoor radon and environmental gamma radiation in Hong Kong

    International Nuclear Information System (INIS)

    Yu, K.N.; Young, E.C.M.; Stokes, M.J.; Luo, D.L.; Zhang, C.X.

    1992-01-01

    Activated charcoal canisters have been used to measured the indoor radon concentrations of 160 sites in different buildings in Hong Kong during the period from July to October 1990. The average value is 40.0 Bq.m -3 . Furthermore, CR-39 nuclear track detectors and two kinds of LiF TLDs have been used to measure the average indoor radon concentrations and the absorbed gamma dose rates in air of 71 sites over the period from January to April 1991. The results all show log-normal distribution. The indoor radon concentrations are respectively 72.2 Bq.m -3 and 155.4 Bq.m -3 for dwellings and offices, while the absorbed gamma dose rates in air are respectively 213.0 nGy.h -1 and 198.3 nGy.h -1 . (author)

  2. Estimation of the variations of ventilation rate and indoor radon concentration using the observed wind velocity and indoor-outdoor temperature difference

    International Nuclear Information System (INIS)

    Nagano, Katsuhiro; Inose, Yuichi; Kojima, Hiroshi

    2006-01-01

    The indoor radon concentration in the building depends on the ventilation rate. Measurement results of indoor-outdoor pressure difference showed the ventilation rate correlated closely with the indoor-outdoor pressure difference. The observation results showed that one of factor of indoor-outdoor pressure difference was the wind velocity. When the wind velocity is small, the ventilation rate is affected by the indoor-outdoor temperature difference and the effect depends on the wind velocity. The temporal variation of indoor radon concentration was predicted by the time depending indoor radon balance model and the ventilation rate estimated from the wind velocity and the indoor-outdoor temperature difference. The temporal variations of predicted radon concentration gave good agreement with the experimental values. The measurement method, indoor radon concentration and ventilation rate, factors of temporal variation of ventilation rate, and prediction of indoor radon concentration are reported. (S.Y.)

  3. Review of the indoor environmental quality and energy consumption studies for low income households in Europe.

    Science.gov (United States)

    Kolokotsa, D; Santamouris, M

    2015-12-01

    The term energy poverty is used to describe a situation of a household not able to satisfy socially and materially the required levels of its energy services. Energy and fuel poverty is an increasing problem in the European Union. Although the specific conditions vary from country to country the drivers defining fuel and energy poverty are similar in all Europe. This paper aims to present the state of the art regarding the energy demand and indoor environmental quality of low income households in Europe. The characteristics of this specific population group are presented including details on the specific energy consumption, the indoor comfort and finally the impact of the specific living conditions on the occupants' health. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. The effect of the indoor environment on the fate of organic chemicals in the urban landscape.

    Science.gov (United States)

    Cousins, Anna Palm

    2012-11-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical-chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK(OA) and the impact of the ventilation rate on the urban fate of organic chemicals. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Fatigability in basic indoor mobility in nonagenarians

    DEFF Research Database (Denmark)

    Mänty, Minna Regina; Ekmann, Anette; Thinggaard, Mikael

    2012-01-01

    To evaluate the prevalence and associated health factors of indoor mobility-related fatigability in nonagenarians.......To evaluate the prevalence and associated health factors of indoor mobility-related fatigability in nonagenarians....

  6. Outdoor and indoor dose assessment using environmental thermoluminescence dosimeters (TLDs) in Costa Rica

    International Nuclear Information System (INIS)

    Mora, Patricia

    2003-01-01

    Costa Rica lies at the intersection of the Cocos and Caribbean plates in Central America. It has mountain ranges with many active volcanoes along its territory. Its soils are predominantly of volcanic origin. Natural radiation measurements utilising environmental CaF 2 :Dy thermoluminescence dosimeters were used for the first time in Costa Rica by the Dosimetry Section of the Atomic, Nuclear and Molecular Sciences Research Center of the University of Costa Rica. Seven hundred outdoor measurements were obtained in a 3.5-year period at eight different sites throughout the country. One hundred and seventy-four indoor readings were also collected at four sites for a 2-year period. Population-weighted averages give 82 nGy h -1 for outdoors and 130 nGy h -1 for indoors. The values lie on the upper range of worldwide reported values due to reported soil characteristics rich in uranium and potassium. A preliminary population-weighted value of 0.74 mSv/year for the effective dose is calculated for natural terrestrial gamma radiation in Costa Rica

  7. Outdoor-indoor air pollution in urban environment: Challenges and opportunity

    Directory of Open Access Journals (Sweden)

    Dennis Y.C. eLeung

    2015-01-01

    Full Text Available With the continual improvement in our quality of life, indoor air quality has become an important area of concern in the 21st century. Indoor air quality is affected by many factors including the type and running conditions of indoor pollution sources, ventilation conditions, as well as indoor activities. Studies revealed that the outdoor environment is also an important factor that cannot be neglected for indoor air quality studies. In this review, the indoor and outdoor air pollution relationships obtained from different studies are discussed in order to identify the key factors affecting the indoor air quality. As climate change is recognized as imposing impacts on the environment, how it affects the indoor air quality and the health impacts to the occupants will be evaluated in this paper. The major challenges and opportunities in indoor/outdoor air pollution studies will be highlighted.

  8. Indoor Thermal Factors and Symptoms in Office Workers: Findings from the U.S. EPA BASE Study

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark; Mirer, Anna

    2008-06-01

    Some prior research in office buildings has associated higher indoor temperatures even within the recommended thermal comfort range with increased worker symptoms. We reexamined this relationship in data from 95 office buildings in the U.S. Environmental Protection Agency's Building Assessment Survey and Evaluation (BASE) Study. We investigated relationships between building-related symptoms and thermal metrics constructed from real-time measurements. We estimated odds ratios (ORs) and 95percent confidence intervals in adjusted logistic regression models with general estimating equations, overall and by season. Winter indoor temperatures spanned the recommended winter comfort range; summer temperatures were mostly colder than the recommended summer range. Increasing indoor temperatures, overall, were associated with increases in few symptoms. Higher winter indoor temperatures, however, were associated with increases in all symptoms analyzed. Higher summer temperatures, above 23oC, were associated with decreases in most symptoms. Humidity ratio, a metric of absolute humidity, showed few clear associations. Thus, increased symptoms with higher temperatures within the thermal comfort range were found only in winter. In summer, buildings were overcooled, and only the higher observed temperatures were within the comfort range; these were associated with decreased symptoms. Confirmation of these findings would suggest that thermal management guidelines consider health effects as well as comfort.

  9. High concentrations of cadmium, cerium and lanthanum in indoor air due to environmental tobacco smoke

    International Nuclear Information System (INIS)

    Böhlandt, Antje; Schierl, Rudolf; Diemer, Juergen; Koch, Christoph; Bolte, Gabriele; Kiranoglu, Mandy; Fromme, Hermann; Nowak, Dennis

    2012-01-01

    Background: Environmental tobacco smoke (ETS) is one of the most important sources for indoor air pollution and a substantial threat to human health, but data on the concentrations of the trace metals cerium (Ce) and lanthanum (La) in context with ETS exposure are scarce. Therefore the aim of our study was to quantify Ce and La concentrations in indoor air with high ETS load. Methods: In two subsequent investigations Ce, La and cadmium (Cd) in 3 smokers' (11 samples) and 7 non-smokers' (28 samples) households as well as in 28 hospitality venues in Southern Germany were analysed. Active sampling of indoor air was conducted continuously for seven days in every season in the smokers' and non-smokers' residences, and for 4 h during the main visiting hours in the hospitality venues (restaurants, pubs, and discotheques). Results: In terms of residences median levels of Cd were 0.1 ng/m 3 for non-smokers' and 0.8 ng/m 3 for smokers' households. Median concentrations of Ce were 0.4 ng/m 3 and 9.6 ng/m 3 , and median concentrations of La were 0.2 ng/m 3 and 5.9 ng/m 3 for non-smokers' and for smokers' households, respectively. In the different types of hospitality venues median levels ranged from 2.6 to 9.7 ng/m 3 for Cd, from 18.5 to 50.0 ng/m 3 for Ce and from 10.6 to 23.0 ng/m 3 for La with highest median levels in discotheques. Conclusions: The high concentrations of Ce and La found in ETS enriched indoor air of smokers' households and hospitality venues are an important finding as Ce and La are associated with adverse health effects and data on this issue are scarce. Further research on their toxicological, human and public health consequences is urgently required. - Highlights: ► We quantified cer, lanthanum and cadmium concentrations in indoor air. ► Cer and lanthanum concentrations were high in tobacco smoke enriched locations. ► Both elements can be considered as good markers for indoor air quality.

  10. Prolonged self-paced exercise in the heat - environmental factors affecting performance

    DEFF Research Database (Denmark)

    Junge, Nicklas; Jørgensen, Rasmus; Flouris, Andreas D

    2016-01-01

    ) was on average reduced by 15% in the 14 studies that fulfilled the inclusion criteria. Ambient temperature per se was a poor predictor of the integrated environmental heat stress and 2 of the prevailing heat stress indices (WBGT and UTCI) failed to predict the environmental influence on performance. The weighing......In this review we examine how self-paced performance is affected by environmental heat stress factors during cycling time trial performance as well as considering the effects of exercise mode and heat acclimatization. Mean power output during prolonged cycling time trials in the heat (≥30°C...... of wind speed appears to be too low for predicting the effect for cycling in trained acclimatized subjects, where performance may be maintained in outdoor time trials at ambient temperatures as high as 36°C (36°C UTCI; 28°C WBGT). Power output during indoor trials may also be maintained with temperatures...

  11. [Health evaluation of fine particulate matter in indoor air].

    Science.gov (United States)

    2008-11-01

    When evaluating the health effects of indoor air fine particulate matter, the indoor dynamics as well as the physical, chemical and biological properties of fine particles have to be considered. The indoor air fraction PM2.5 largely stems from outdoor air. Accordingly, the German Working Group on Indoor Guideline Values of the Federal Environmental Agency and the States' Health Authorities also recommends WHO's (2006) 24-hour mean guideline value of 25 microg PM2,5 per cubic meter for indoor air evaluation. In contrast to PM2.5, coarse particles (PM10) in schools, kindergartens and dwellings show much higher indoor air concentrations. Additional sources indoors have to be assumed. Because of the different composition of indoor air compared to outdoor air and due to the lack of dose-response relationships of coarse particles in indoor air, the health effects of indoor air PM10 can not be evaluated yet. Sufficient and consistent ventilation is an indispensable basis to reduce PM concentrations in indoor spaces. Furthermore, known sources of PM indoors should be detected consequently and subsequently minimized.

  12. Assessment and predictor determination of indoor aldehyde levels in Paris newborn babies' homes.

    Science.gov (United States)

    Dassonville, C; Demattei, C; Laurent, A-M; Le Moullec, Y; Seta, N; Momas, I

    2009-08-01

    Exposure to indoor chemical air pollutants expected to be potentially involved in allergic respiratory diseases in infants is poorly documented. A specific environmental investigation included in a birth cohort study was carried out to first assess indoor airborne aldehyde levels, using passive devices and their variability within 1 year (1, 6, 9 and 12 months) in the bedroom of 196 Paris infants, and second, to identify predictors for aldehyde concentrations using interviewer administered questionnaires about housing factors. Comfort parameters and carbon dioxide levels were measured simultaneously. Aldehydes were detected in almost all dwellings and geometric mean levels (geometric standard deviation) at the first visit were respectively for formaldehyde, acetaldehyde, hexanal, and pentanal 19.4 (1.7) microg/m(3), 8.9 (1.8) microg/m(3), 25.3 (3.1) microg/m(3), 3.7 (2.3) microg/m(3), consistent with earlier published results. Generalized Estimating Equation multivariate analyses showed that, apart from comfort parameters, aeration and season, the main indoor aldehyde sources were either continuous (building materials and coverings especially when they were new) or discontinuous (smoking, use of air fresheners and cleaning products, DIY etc...). Finally, the data collected by questionnaires should be sufficient to enable us to classify each infant in our cohort study according to his/her degree of exposure to the main aldehydes. This analysis contributed to document indoor aldehyde levels in Parisian homes and to identify factors determining these levels. In the major part of newborn babies' homes, indoor formaldehyde levels were above the guideline value of 10 microg/m(3) proposed by the French Agency for Environmental and Occupational Health Safety for long-term exposure. Given this result, it is essential to study the health impact of exposure to aldehydes especially formaldehyde on the incidence of respiratory and allergic symptoms, particularly during the

  13. Feasible Indoor Air-related measures against Avian Influenza

    NARCIS (Netherlands)

    Franchimon, F.; Pernot, C.E.E.; Bronswijk, van J.E.M.H.; Olesen, BW; Wargocki, P; Strøm-Tejsen, P; Zukowska, D; Toftum, J

    2008-01-01

    The threat of a new pandemic has forced the WHO to publish preparedness plans. Although WHO recognized the effect of airborne transmission of the causative agent, they did not attempt to include feasible measures for indoor environmental control as yet. The efficacy of indoor humidity control

  14. Assessment of Indoor Environmental Quality (IEQ: Students Well-Being in University Classroom with the Application of Landscaping

    Directory of Open Access Journals (Sweden)

    Jamaludin Nurul Malina

    2016-01-01

    Full Text Available The environmental quality (IEQ in a building is an important element to perceive the good health and comfort level for the building occupants. However, each building contributes different environmental quality results towards the indoor spaces and the occupants. Learning environment is one of the spaces that need attention as it is related to student’s well being as well as their learning performance. Existing knowledge on IEQ is still limited concerning the desirable levels of air quality, maintenance, and other factors affecting IEQ in Malaysian educational establishment. Therefore, the study of indoor environment quality in buildings has been carried out in educational building as it acts as important place in learning process. The methodologies used to conduct this research are divided into two methods, which are classroom measurement normal condition and classroom intervention setting. This is done in order to compare and monitor the improvement of environment in the classroom. This research focuses on the comparison of IEQ in different classroom environment setting and the student satisfaction level in their normal classroom environment. Measurement of temperature (°C, relative humidity, carbon dioxide (CO2, Volatile Organic Compound (VOC, dust particles (PM10, lighting (lux, and noise (decibel in the classroom were collected and questionnaires were distributed among the students. This research found that most of the elements in the classroom was incompliance with the standard threshold limit value. The level of VOC in the classroom was noted to be significantly high (11.7ppm compared to the standard threshold limit. An intervention on the normal condition classroom was set up with selected plant placed in the classroom. Results show a tremendous reduction in the percentage of relative humidity, level of TVOC, as well as CO2.

  15. Measurements of indoor 222Rn concentration in two art galleries

    International Nuclear Information System (INIS)

    Carneiro, Luana Gomes; Braz, Delson; Jesus, Edgar Francisco de; Cunha, Kenya Dias da; Medeiros, Geiza; Zouain, Felipe; Pitassi, Gabriel; Leite, Carlos Barros; Cardoso, Katia

    2009-01-01

    It is point out that radon and their decay products in environment give high dose to human lung. Studies indicate that the indoor radon inhalation by humans has been considered probably the second most important cause of lung cancer after of smoking. A passive-type radon detector was used for measuring indoor radon concentration in two art galleries at Rio de Janeiro city during 90 days January to March, 2009. The aim of this study is to evaluate the occupational and public radon exposure in art galleries and museums. This paper shows the preliminary results of samples collected at two art galleries located in Gavea, Rio de Janeiro city. 30 LEXAN (GE) track detectors were exposed in the air (indoor as well as outdoor). The samples were collected in the same building which is a construction of XIX century. The analysis of the results suggests that the 222 Rn concentration levels are different in both sampling site, in closed environmental, demonstrating that, although the construction materials are the same the absence of circulating air is a factor very important to increase the concentration of indoor Rn. (author)

  16. Risk factors related to Toxoplasma gondii seroprevalence in indoor-housed Dutch dairy goats.

    Science.gov (United States)

    Deng, Huifang; Dam-Deisz, Cecile; Luttikholt, Saskia; Maas, Miriam; Nielen, Mirjam; Swart, Arno; Vellema, Piet; van der Giessen, Joke; Opsteegh, Marieke

    2016-02-01

    Toxoplasma gondii can cause disease in goats, but also has impact on human health through food-borne transmission. Our aims were to determine the seroprevalence of T. gondii infection in indoor-housed Dutch dairy goats and to identify the risk factors related to T. gondii seroprevalence. Fifty-two out of ninety approached farmers with indoor-kept goats (58%) participated by answering a standardized questionnaire and contributing 32 goat blood samples each. Serum samples were tested for T. gondii SAG1 antibodies by ELISA and results showed that the frequency distribution of the log10-transformed OD-values fitted well with a binary mixture of a shifted gamma and a shifted reflected gamma distribution. The overall animal seroprevalence was 13.3% (95% CI: 11.7–14.9%), and at least one seropositive animal was found on 61.5% (95% CI: 48.3–74.7%) of the farms. To evaluate potential risk factors on herd level, three modeling strategies (Poisson, negative binomial and zero-inflated) were compared. The negative binomial model fitted the data best with the number of cats (1–4 cats: IR: 2.6, 95% CI: 1.1–6.5; > = 5 cats:IR: 14.2, 95% CI: 3.9–51.1) and mean animal age (IR: 1.5, 95% CI: 1.1–2.1) related to herd positivity. In conclusion, the ELISA test was 100% sensitive and specific based on binary mixture analysis. T. gondii infection is prevalent in indoor housed Dutch dairy goats but at a lower overall animal level seroprevalence than outdoor farmed goats in other European countries, and cat exposure is an important risk factor.

  17. Estimating the health benefit of reducing indoor air pollution in a randomized environmental intervention.

    Science.gov (United States)

    Peng, Roger D; Butz, Arlene M; Hackstadt, Amber J; Williams, D'Ann L; Diette, Gregory B; Breysse, Patrick N; Matsui, Elizabeth C

    2015-02-01

    Recent intervention studies targeted at reducing indoor air pollution have demonstrated both the ability to improve respiratory health outcomes and to reduce particulate matter (PM) levels in the home. However, these studies generally do not address whether it is the reduction of PM levels specifically that improves respiratory health. In this paper we apply the method of principal stratification to data from a randomized air cleaner intervention designed to reduce indoor PM in homes of children with asthma. We estimate the health benefit of the intervention amongst study subjects who would experience a substantial reduction in PM in response to the intervention. For those subjects we find an increase in symptom-free days that is almost three times as large as the overall intention-to-treat effect. We also explore the presence of treatment effects amongst those subjects whose PM levels would not respond to the air cleaner. This analysis demonstrates the usefulness of principal stratification for environmental intervention trials and its potential for much broader application in this area.

  18. Prediction of Human Performance Using Electroencephalography under Different Indoor Room Temperatures

    Science.gov (United States)

    Zhang, Tinghe; Mao, Zijing; Xu, Xiaojing; Zhang, Lin; Pack, Daniel J.; Dong, Bing; Huang, Yufei

    2018-01-01

    Varying indoor environmental conditions is known to affect office worker’s performance; wherein past research studies have reported the effects of unfavorable indoor temperature and air quality causing sick building syndrome (SBS) among office workers. Thus, investigating factors that can predict performance in changing indoor environments have become a highly important research topic bearing significant impact in our society. While past research studies have attempted to determine predictors for performance, they do not provide satisfactory prediction ability. Therefore, in this preliminary study, we attempt to predict performance during office-work tasks triggered by different indoor room temperatures (22.2 °C and 30 °C) from human brain signals recorded using electroencephalography (EEG). Seven participants were recruited, from whom EEG, skin temperature, heart rate and thermal survey questionnaires were collected. Regression analyses were carried out to investigate the effectiveness of using EEG power spectral densities (PSD) as predictors of performance. Our results indicate EEG PSDs as predictors provide the highest R2 (> 0.70), that is 17 times higher than using other physiological signals as predictors and is more robust. Finally, the paper provides insight on the selected predictors based on brain activity patterns for low- and high-performance levels under different indoor-temperatures. PMID:29690601

  19. Report on HVAC option selections for a relocatable classroom energy and indoor environmental quality field study

    OpenAIRE

    Apte, Michael G.; Delp, Woody W.; Diamond, Richard C.; Hodgson, Alfred T.; Kumar, Satish; Rainer, Leo I.; Shendell, Derek G.; Sullivan, Doug P.; Fisk, William J.

    2001-01-01

    It is commonly assumed that efforts to simultaneously develop energy efficient building technologies and to improve indoor environmental quality (IEQ) are unfeasible. The primary reason for this is that IEQ improvements often require additional ventilation that is costly from an energy standpoint. It is currently thought that health and productivity in work and learning environments requires adequate, if not superior, IEQ. Despite common assumptions, opportunities do exist to design bui...

  20. Environmental risk factors of childhood asthma in urban centers.

    Science.gov (United States)

    Malveaux, F J; Fletcher-Vincent, S A

    1995-09-01

    Asthma morbidity and mortality are disproportionately high in urban centers, and minority children are especially vulnerable. Factors that contribute to this dilemma include inadequate preventive medical care for asthma management, inadequate asthma knowledge and management skills among children and their families, psychosocial factors, and environmental exposure to allergens or irritants. Living in substandard housing often constitutes excess exposure to indoor allergens and pollutants. Allergens associated with dust mites (DM) and cockroaches (CR) are probably important in both onset and worsening of asthma symptoms for children who are chronically exposed to these agents. Young children spend a great deal of time on or near the floor where these allergens are concentrated in dust. Of children (2 to 10 years of age) living in metropolitan Washington, DC, 60% were found to be sensitive to CR and 72% were allergic to DM. Exposure to tobacco smoke contributes to onset of asthma earlier in life and is a risk factor for asthma morbidity. Since disparity of asthma mortality and morbidity among minority children in urban centers is closely linked to socioeconomic status and poverty, measures to reduce exposure to environmental allergens and irritants and to eliminate barriers to access to health care are likely to have a major positive impact. Interventions for children in urban centers must focus on prevention of asthma symptoms and promotion of wellness.

  1. Air pollution, a rising environmental risk factor for cognition, neuroinflammation and neurodegeneration: The clinical impact on children and beyond.

    Science.gov (United States)

    Calderón-Garcidueñas, L; Leray, E; Heydarpour, P; Torres-Jardón, R; Reis, J

    2016-01-01

    Air pollution (indoors and outdoors) is a major issue in public health as epidemiological studies have highlighted its numerous detrimental health consequences (notably, respiratory and cardiovascular pathological conditions). Over the past 15 years, air pollution has also been considered a potent environmental risk factor for neurological diseases and neuropathology. This review examines the impact of air pollution on children's brain development and the clinical, cognitive, brain structural and metabolic consequences. Long-term potential consequences for adults' brains and the effects on multiple sclerosis (MS) are also discussed. One challenge is to assess the effects of lifetime exposures to outdoor and indoor environmental pollutants, including occupational exposures: how much, for how long and what type. Diffuse neuroinflammation, damage to the neurovascular unit, and the production of autoantibodies to neural and tight-junction proteins are worrisome findings in children chronically exposed to concentrations above the current standards for ozone and fine particulate matter (PM2.5), and may constitute significant risk factors for the development of Alzheimer's disease later in life. Finally, data supporting the role of air pollution as a risk factor for MS are reviewed, focusing on the effects of PM10 and nitrogen oxides. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  2. Indoor environmental quality and energy consumption relation in offices: case study of two offices in Iran

    Energy Technology Data Exchange (ETDEWEB)

    Ashrafian, Touraj; Moazzen Ferdos, Nazanin [Islamic Azad University Tabriz branch (Iran, Islamic Republic of)], email: t.ashrafian@gmail.com, email: moazzen_arch@yahoo.com; Haghlesan, Masoud [Islamic Azad University, Ilkhichi Branch (Iran, Islamic Republic of)], email: mhaghlesan@yahoo.com

    2011-07-01

    Nowadays, most people spend more than 90% of their time indoors, therefore the quality of the indoor environment has a significant impact on human health. However, improving indoor environment quality (IEQ) requires a higher energy consumption through increasing lighting, heating and cooling. The aim of this study is to determine an appropriate level of IEQ with the least energy consumption possible. The relation between energy consumption and IEQ in 2 offices in Iran has been studied through the use of questionnaires and simulations. It was found that IEQ has a great impact on workers' productivity and that diminishing the energy consumption does not necessarily translate into economic benefits. In addition it was found that lighting and heating are the main sources of energy consumption and that noise and light are what most influence worker productivity. This study highlighted the relation between energy consumption and IEQ and pointed out the most important factors.

  3. Quantitative relationships between occupant satisfaction and aspects of indoor environmental quality and building design

    DEFF Research Database (Denmark)

    Frontczak, Monika Joanna; Schiavon, Stefano; Goins, John

    2011-01-01

    The paper examines which indoor environmental parameters and building features contribute occupants’ satisfaction in office buildings. The study analyzed data from a web-based survey administered to 52,980 occupants in 351 office buildings over ten years at the Center for the Built Environment...... parameters listed in the survey contributed to overall workspace satisfaction. The most important parameters were: satisfaction with amount of space (odds ratio OR 1.57), noise (OR 1.27) and visual privacy (OR 1.26). Satisfaction with amount of space was not noticeably affected by size of workspace...

  4. Environmental dosimetry of radon-222 and daughters: measurement of absolute calibration factors of CR-39 considering the plate-out effects and environmental factors

    International Nuclear Information System (INIS)

    Paulo, S.R. de.

    1991-08-01

    The subject of this work concerns with the measurement of absolute calibration factors for the use of CR-39 as an absolute detector in indoor and daughters monitoring. Up to now the usefulness of calibration factors was restricted to environmental conditions equal (or very close) to those worthing during their determinations. This fact is consequence of the difficulties related to the understanding of the plate-out properties of radon daughters activity in the air. The plate-out effects on radon daughters monitoring performed by SSNTDs are studied. Our experimental results are in agreement with those of other authors about the great sensitivity of CR-39 to the plate-out effects, fact that recommended its use in this work. Being succeeded in the employment of CR-39 as an alpha-spectrometer we concluded that some important information (like the radon daughters deposition rates on the walls of an environment) can be achieved. The knowledge about the behavior of plate-out made possible the determination of the ranges in zenithal angle and energy where CR-39 can detect alpha-particles with efficiency of 100%, at our conditions of track observation. In this way, we obtained calibration factors for CR-39 that are weakly dependent on environmental conditions. We think that these results can contribute to the improvement of RD (Radiation Detector) detection techniques. (author). 159 refs, 106 figs, 05 tabs

  5. Indoor air quality

    International Nuclear Information System (INIS)

    Hollowell, C.D.

    1981-06-01

    Rising energy prices, among other factors, have generated an incentive to reduce ventilation rates and thereby reduce the cost of heating and cooling buildings. Reduced ventilation in buildings may significantly increase exposure to indoor air pollution and perhaps have adverse effects on occupant health and comfort. Preliminary findings suggest that reduced ventilation may adversely affect indoor air quality unless appropriate control strategies are undertaken. The strategies used to control indoor air pollution depend on the specific pollutant or class of pollutants encountered, and differ somewhat depending on whether the application is to an existing building or a new building under design and construction. Whenever possible, the first course of action is prevention or reduction of pollutant emissions at the source. In most buildings, control measures involve a combination of prevention, removal, and suppression. Common sources of indoor air pollution in buildings, the specific pollutants emitted by each source, the potential health effects, and possible control techniques are discussed

  6. Polluted air--outdoors and indoors.

    Science.gov (United States)

    Myers, I; Maynard, R L

    2005-09-01

    Many air pollutants which are considered important in ambient (outdoor) air are also found, sometimes at higher levels, in indoor air. With demanding standards having been set for many of these pollutants, both in the workplace and ambient air, consideration of the problems posed by indoor pollution is gaining pace. Studies on exposure to pollutants found in the indoor domestic environment are increasing and are contributing to an already significant compilation of datasets. Improvement in monitoring techniques has helped this process. Documented reports of fatalities from carbon monoxide poisonings are still worrying. However, studies on health effects of non-fatal, long term, low dose, indoor exposure to carbon monoxide and other pollutants, are still inconclusive and too infrequently documented. Of particular concern are the levels of air pollutants found in the domestic indoor environment in developing countries, despite simple interventions such as vented stoves having shown their value. Exposure to biomass smoke is still a level that would be considered unacceptable on health grounds in developed countries. As in the occupational environment, steps need to be taken to control the risks from exposure to the harmful constituents of indoor air in the home. However, the difficulty regarding regulation of the domestic indoor environment is its inherent privacy. Monitoring levels of pollutants in the home and ensuring regulations are adhered to, would likely prove difficult, especially when individual behaviour patterns and activities have the greatest influence on pollutant levels in indoor air. To this end, the Department of Health is developing guidance on indoor air pollution to encourage the reduction of pollutant levels in indoor domestic air. The importance of the effects of domestic indoor air on health and its contribution to the health of the worker are increasingly appreciated. Occupational physicians, by training and interest, are well placed to extend

  7. Core public health functions for BC : evidence review : air quality-indoor

    Energy Technology Data Exchange (ETDEWEB)

    Copes, R.; Ouellette, V.; Lee, K.S.; Brauer, M. [British Columbia Ministry of Health, Victoria, BC (Canada)

    2006-04-15

    Indoor sources of pollutants can have a major impact on the health of Canadians, as pollutant concentrations are often higher indoors than outdoors. This paper assessed data compiled by public health indoor air interventions. The aim of the study was to identify the current state of evidence on the impacts of indoor pollution in order to develop performance improvement plans for public health programs in British Columbia (BC). The literature review used several databases to review interventions involving humidity control; ventilation; particulate matter; indoor allergens; and environmental tobacco smoke. Results of the review showed that improving inadequate ventilation can significantly decrease the prevalence of sick building syndrome as well as other self-reported symptoms attributed to indoor air pollution. A review of the literature also demonstrated that many building ventilation systems are not functioning to design specifications. The poor quality of studies on the health impacts of particulate matter or dust made it difficult to fully assess the benefits of particle filtration on human health. Studies investigating the impacts of controlling indoor allergens suggested that the avoidance of dust mites may benefit people with allergies. Evidence gained from studies on environmental tobacco smoke showed that banning or restricting smoking will reduce the burden of illness from pollutants in indoor air. 20 refs., 3 tabs.

  8. Core public health functions for BC : evidence review : air quality-indoor

    International Nuclear Information System (INIS)

    Copes, R.; Ouellette, V.; Lee, K.S.; Brauer, M.

    2006-04-01

    Indoor sources of pollutants can have a major impact on the health of Canadians, as pollutant concentrations are often higher indoors than outdoors. This paper assessed data compiled by public health indoor air interventions. The aim of the study was to identify the current state of evidence on the impacts of indoor pollution in order to develop performance improvement plans for public health programs in British Columbia (BC). The literature review used several databases to review interventions involving humidity control; ventilation; particulate matter; indoor allergens; and environmental tobacco smoke. Results of the review showed that improving inadequate ventilation can significantly decrease the prevalence of sick building syndrome as well as other self-reported symptoms attributed to indoor air pollution. A review of the literature also demonstrated that many building ventilation systems are not functioning to design specifications. The poor quality of studies on the health impacts of particulate matter or dust made it difficult to fully assess the benefits of particle filtration on human health. Studies investigating the impacts of controlling indoor allergens suggested that the avoidance of dust mites may benefit people with allergies. Evidence gained from studies on environmental tobacco smoke showed that banning or restricting smoking will reduce the burden of illness from pollutants in indoor air. 20 refs., 3 tabs

  9. Residential indoor air quality guideline : ozone

    International Nuclear Information System (INIS)

    2010-01-01

    Ozone (O 3 ) is a colourless gas that reacts rapidly on surfaces and with other constituents in the air. Sources of indoor O 3 include devices sold as home air cleaners, and some types of office equipment. Outdoor O 3 is also an important contributor to indoor levels of O 3 , depending on the air exchange rate with indoor environments. This residential indoor air quality guideline examined factors that affect the introduction, dispersion and removal of O 3 indoors. The health effects of prolonged exposure to O 3 were discussed, and studies conducted to evaluate the population health impacts of O 3 were reviewed. The studies demonstrated that there is a significant association between ambient O 3 and adverse health impacts. Exposure guidelines for residential indoor air quality were discussed. 14 refs.

  10. SOME ENVIRONMENTEAL FACTORS AFFECTING BROILER HOUSING IN WINTER SEASON

    Directory of Open Access Journals (Sweden)

    Tarek FOUDA

    2013-01-01

    Full Text Available The main objective of this study was to study some environmental factors affecting broiler housing in winter season. The results showed that, temperature fluctuations between house ceiling and floor ranged between 0.4 to 5.93 ºC during the first two days of age. The average house temperature reduced gradually from 29.7 to 21.3 ºC. The indoor relative humidity ranged between 43.6 to 74.3 %. Specific heating power, specific fuel consumption and heating energy requirements ranged between 3850.2 W/ºC , 0.34 kg /h. ºC and 308.9 kJ/h. kg at the first week of age to 6213.4 W/ºC , 0.36 kg /h. ºC and 19.3 kJ/h. kg at the end of the life respectively

  11. Life cycle and reproduction of house-dust mites: environmental factors influencing mite populations.

    Science.gov (United States)

    Hart, B J

    1998-01-01

    An understanding of the life cycle of house-dust mites, as well as environmental factors influencing mite populations, can be exploited in mite control. The most important limiting factor for house-dust-mite populations is air humidity. House-dust mites osmoregulate through the cuticle and therefore require a high ambient air humidity to prevent excessive water loss. In addition, the supracoxal glands actively take up ambient water vapour, and the protonynph stage of the life cycle is resistant to desiccation. Larger house-dust-mite populations are found when the absolute indoor air humidity is above 7 g/kg (45% relative humidity at 20 degrees C). Consequently, ventilation by air-conditioning systems is being developed as a means of control. A number of other aspects of the domestic environment are also being manipulated in an integrated approach to render the habitat less suitable for mites. The potential exists for developing models for house-dust mite populations, environmental characteristics, and the effects of various approaches to control.

  12. An RFID Indoor Positioning Algorithm Based on Bayesian Probability and K-Nearest Neighbor.

    Science.gov (United States)

    Xu, He; Ding, Ye; Li, Peng; Wang, Ruchuan; Li, Yizhu

    2017-08-05

    The Global Positioning System (GPS) is widely used in outdoor environmental positioning. However, GPS cannot support indoor positioning because there is no signal for positioning in an indoor environment. Nowadays, there are many situations which require indoor positioning, such as searching for a book in a library, looking for luggage in an airport, emergence navigation for fire alarms, robot location, etc. Many technologies, such as ultrasonic, sensors, Bluetooth, WiFi, magnetic field, Radio Frequency Identification (RFID), etc., are used to perform indoor positioning. Compared with other technologies, RFID used in indoor positioning is more cost and energy efficient. The Traditional RFID indoor positioning algorithm LANDMARC utilizes a Received Signal Strength (RSS) indicator to track objects. However, the RSS value is easily affected by environmental noise and other interference. In this paper, our purpose is to reduce the location fluctuation and error caused by multipath and environmental interference in LANDMARC. We propose a novel indoor positioning algorithm based on Bayesian probability and K -Nearest Neighbor (BKNN). The experimental results show that the Gaussian filter can filter some abnormal RSS values. The proposed BKNN algorithm has the smallest location error compared with the Gaussian-based algorithm, LANDMARC and an improved KNN algorithm. The average error in location estimation is about 15 cm using our method.

  13. Indoor Air Quality and Health

    Directory of Open Access Journals (Sweden)

    Alessandra Cincinelli

    2017-10-01

    Full Text Available In the last few decades, Indoor Air Quality (IAQ has received increasing attention from the international scientific community, political institutions, and environmental governances for improving the comfort, health, and wellbeing of building occupants.[...

  14. The role of the indoor environment: Residential determinants of allergy, asthma and pulmonary function in children from a US-Mexico border community.

    Science.gov (United States)

    Svendsen, Erik R; Gonzales, Melissa; Commodore, Adwoa

    2018-03-01

    The El Paso Children's Health Study examined environmental risk factors for allergy and asthma among fourth and fifth grade schoolchildren living in a major United States-Mexico border city. Complete questionnaire information was available for 5210 children, while adequate pulmonary function data were available for a subset of 1874. Herein we studied indoor environmental health risk factors for allergy and asthma. Several indoor environmental risk factors were associated with allergy and asthma. In particular, we found that ant and spider pest problems, pet dogs, fireplace heat, central air conditioning, humidifier use, and cooking with gas stoves were positively associated with both allergy and asthma prevalence. With regards to asthma severity, our analysis indicated that exposure to pet dogs increased monotonically with increasing asthma severity while the lack of any heat source and gas stove use for cooking decreased monotonically with increasing asthma severity. Lung function also decreased among children who lived in homes with reported cockroach pest problem in the past year without concurrent use of pesticides. These effects on pulmonary function were present even after excluding children with a current physician's diagnosis of asthma. Clinicians and public health professionals may need to look closely at the contribution of these indoor risk factors on pulmonary health and quality of life among susceptible populations. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Measurements of Energy Performance and Indoor Environmental Quality in 10 Danish Passive Houses

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Jensen, Rasmus Lund

    2009-01-01

    The paper describes the first results from a large Danish project regarding measurements of energy performance and indoor environmental quality in 10 Danish Passive Houses. The project includes both qualitative and quantitative analyses. This paper describes the first results from the quantitative...... part. The house considered in this paper has an air change rate (ACR) of 0.34 h-1 and the results from the first few months of measurements show excellent results when relative humidity (RH) and CO2-levels are considered. When the temperatures are assessed problems with slight overheating are found...... used for heating domestic hot water is very similar to conventional houses....

  16. Protocol for maximizing energy savings and indoor environmental quality improvements when retrofitting apartments

    Energy Technology Data Exchange (ETDEWEB)

    Noris, Federico [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Delp, William W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Vermeer, Kimberly [Urban Habitat Initiatives Inc., Boston, MA (United States); Adamkiewicz, Gary [Harvard School of Public Health, Boston, MA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-06-01

    The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

  17. Psychosocial dimensions of solving an indoor air problem.

    Science.gov (United States)

    Lahtinen, Marjaana; Huuhtanen, Pekka; Kähkönen, Erkki; Reijula, Kari

    2002-03-01

    This investigation focuses on the psychological and social dimensions of managing and solving indoor air problems. The data were collected in nine workplaces by interviews (n = 85) and questionnaires (n = 375). Indoor air problems in office environments have traditionally utilized industrial hygiene or technical expertise. However, indoor air problems at workplaces are often more complex issues to solve. Technical questions are inter-related with the dynamics of the work community, and the cooperation and interaction skills of the parties involved in the solving process are also put to the test. In the present study, the interviewees were very critical of the process of solving the indoor air problem. The responsibility for coordinating the problem-managing process was generally considered vague, as were the roles and functions of the various parties. Communication problems occurred and rumors about the indoor air problem circulated widely. Conflicts were common, complicating the process in several ways. The research focused on examining different ways of managing and resolving an indoor air problem. In addition, reference material on the causal factors of the indoor air problem was also acquired. The study supported the hypothesis that psychosocial factors play a significant role in indoor air problems.

  18. An indoor chemical cocktail

    Science.gov (United States)

    Gligorovski, Sasho; Abbatt, Jonathan P. D.

    2018-02-01

    In the past 50 years, many of the contaminants and chemical transformations that occur in outdoor waters, soils, and air have been elucidated. However, the chemistry of the indoor environment in which we live most of the time—up to 90% in some societies—is not nearly as well studied. Recent work has highlighted the wealth of chemical transformations that occur indoors. This chemistry is associated with 3 of the top 10 risk factors for negative health outcomes globally: household air pollution from solid fuels, tobacco smoking, and ambient particulate matter pollution (1). Assessments of human exposure to indoor pollutants must take these reactive processes into consideration.

  19. ASSESSMENT OF THE INDOOR ENVIRONMENT AND IMPLICATIONS FOR HEALTH IN ROMA VILLAGES IN SLOVAKIA AND ROMANIA

    Science.gov (United States)

    Majdan, Marek; Coman, Alexandru; Gallová, Eva; Ďuricová, Janka; Kállayová, Daniela; Kvaková, Mária; Bošák, Ľuboš

    2013-01-01

    SUMMARY Objectives The objective of this paper is to provide information on indoor air quality and on the quality of the broader indoor environment of the houses in Roma villages in Slovakia and Romania and to discuss possible implications for health. Methods Indoor air was sampled in 11 houses in a Romanian Roma village and in 19 houses in a Slovakian Roma village. Levels of Carbon Monoxide (CO), Carbon Dioxide (CO2), total particulate matter (PM), temperature and humidity were measured. A questionnaire and a checklist were used to obtain additional information on the indoor environment and behavioural factors. We have sampled the same houses in winter and in summer. Results Levels of CO and CO2 were higher in winter in both countries as compared to summer. The limit value of 10 mg/m3 CO was exceeded in a few cases in both countries. In general, levels of CO, CO2 and PM were higher in Romania. Further environmental and behavioural hazards such as indoor smoking, pets inside or lack of ventilation were found. The reported self-perceived quality of the indoor environment was poor in many aspects. Conclusions Our findings of CO, CO2 and PM levels suggest that indoor air pollution in Roma settlements has the potential to be a health threat. The fact that the inhabitants spend a relatively long time inside the houses and that a number of additional environmental and behavioural hazards were identified by our study emphasizes the importance of the indoor air quality for health and thus priority attention should be paid to these issues by health authorities and researchers. Further research is essential and study designs must consider cultural background and specific characteristics of the community, especially in order to obtain valid data on health outcomes. PMID:23285520

  20. In search of the comfortable indoor environment: A comparison of the utility of objective and subjective indicators of indoor comfort

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, Niklas; Skoog, Jennie [Building Services Engineering, Department of Energy and Environment, Chalmers University of Technology, Gothenburg (Sweden); Vaestfjaell, Daniel [Department of Psychology, Goeteborg University (Sweden)

    2007-05-15

    Today, many procedures for assessing the indoor environment rely on both subjective and objective indicators (e.g. ANSI/ASHRAE 55-2004; ISO 10551). It is however unclear how these two types of measurements are related to perceived comfort. This article aims at assessing the relative utility of subjective (rating scale measures) and objective indicators of perceived comfort of indoor environments. In a hospital setting, physical environmental variables (e.g. temperature, relative humidity and noise level) were simultaneously measured as respondents (both patients and staff) rated their perception of the indoor environment. Regression analyses indicated that the subjective sensory ratings were significantly better than objective indicators at predicting overall rated indoor comfort. These results are discussed in relation to existing measurement procedures and standards. (author)

  1. Public effective doses from environmental natural gamma exposures indoors and outdoors in Iran

    International Nuclear Information System (INIS)

    Sohrabi, Mehdi; Roositalab, Jalil; Mohammadi, Jahangir

    2015-01-01

    The effective doses of public in Iran due to external gamma exposures from terrestrial radionuclides and from cosmic radiation indoors and outdoors of normal natural background radiation areas were determined by measurements and by calculations. For direct measurements, three measurement methods were used including a NaI(TI) scintillation survey meter for preliminary screening, a pressurised ionising chamber for more precise measurements and early warning measurement equipment systems. Measurements were carried out in a large number of locations indoors and outdoors ∼1000 houses selected randomly in 36 large cities of Iran. The external gamma doses of public from living indoors and outdoors were also calculated based on the radioactivity measurements of samples taken from soil and building materials by gamma spectrometry using a high-resolution HPGe system. The national mean background gamma dose rates in air indoors and outdoors based on measurements are 126.9±24.3 and 111.7±17.72 nGy h -1 , respectively. When the contribution from cosmic rays was excluded, the values indoors and outdoors are 109.2±20.2 and 70.2±20.59.4 nGy h -1 , respectively. The dose rates determined for indoors and outdoors by calculations are 101.5±9.2 and 72.2±9.4 nGy h -1 , respectively, which are in good agreement with directly measured dose rates within statistical variations. By considering a population-weighted mean for terrestrial radiation, the ratio of indoor to outdoor dose rates is 1.55. The mean annual effective dose of each individual member of the public from terrestrial radionuclides and cosmic radiation, indoors and outdoors, is 0.86±0.16 mSv y -1 by measurements and 0.8±0.2 mSv y -1 by calculations. The results of this national survey of public annual effective doses from national natural background external gamma radiation determined by measurements and calculations indoors and outdoors of 1000 houses in 36 cities of Iran are presented and discussed. (authors)

  2. Gender, airborne chemical monitoring, and physical work environment are related to indoor air symptoms among nonindustrial workers in the Klang Valley, Malaysia

    Directory of Open Access Journals (Sweden)

    Syazwan AI

    2013-03-01

    level indoors.Conclusion: Exposure to pollutants (total volatile organic compounds, carbon monoxide, and formaldehyde and physical stressors (air temperature and relative humidity influence reported symptoms of office workers. These parameters should be focused upon and graded as one of the important elements in the grading procedure when qualitatively evaluating the indoor environment.Keywords: sick building syndrome (SBS, regression analysis, environmental climate factor, occupational exposure, asthma, allergy

  3. Indoor environment program. 1994 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Daisey, J.M.

    1995-04-01

    Buildings use approximately one-third of the energy consumed in the United States. The potential energy savings derived from reduced infiltration and ventilation in buildings are substantial, since energy use associated with conditioning and distributing ventilation air is about 5.5 EJ per year. However, since ventilation is the dominant mechanism for removing pollutants from indoor sources, reduction of ventilation can have adverse effects on indoor air quality, and on the health, comfort, and productivity of building occupants. The Indoor Environment Program in LBL`s Energy and Environment Division was established in 1977 to conduct integrated research on ventilation, indoor air quality, and energy use and efficiency in buildings for the purpose of reducing energy liabilities associated with airflows into, within, and out of buildings while maintaining or improving occupant health and comfort. The Program is part of LBL`s Center for Building Science. Research is conducted on building energy use and efficiency, ventilation and infiltration, and thermal distribution systems; on the nature, sources, transport, transformation, and deposition of indoor air pollutants; and on exposure and health risks associated with indoor air pollutants. Pollutants of particular interest include radon; volatile, semivolatile, and particulate organic compounds; and combustion emissions, including environmental tobacco smoke, CO, and NO{sub x}.

  4. Indoor environment program - 1995 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Daisey, J.M.

    1996-06-01

    Buildings use approximately one-third of the energy consumed in the United States. The potential energy savings derived from reduced infiltration and ventilation in buildings are substantial, since energy use associated with conditioning and distributing ventilation air is about 5.5 EJ per year. However, since ventilation is the dominant mechanism for removing pollutants from indoor sources, reduction of ventilation can have adverse effects on indoor air quality, and on the health, comfort, and productivity of building occupants. The Indoor Environment Program in LBL`s Energy and Environment Division was established in 1977 to conduct integrated research on ventilation, indoor air quality, and energy use and efficiency in buildings for the purpose of reducing energy liabilities associated with airflows into, within, and out of buildings while maintaining or improving occupant health and comfort. The Program is part of LBL`s Center for Building Science. Research is conducted on building energy use and efficiency, ventilation and infiltration, and thermal distribution systems; on the nature, sources, transport, transformation, and deposition of indoor air pollutants; and on exposure and health risks associated with indoor air pollutants. Pollutants of particular interest include radon; volatile, semivolatile, and particulate organic compounds; and combustion emissions, including environmental tobacco smoke, CO, and NO{sub x}.

  5. HEALTH STATUS, ENVIRONMENTAL LIVING CONDITIONS AND MICROBIAL INDOOR AIR QUALITY AMONG MIGRANT WORKER HOUSEHOLDS

    Science.gov (United States)

    Luksamijarulkul, Pipat; Suknongbung, Siranee; Vatanasomboon, Pisit; Sujirarut, Dusit

    2017-03-01

    A large number of migrants have move to cities in Thailand seeking employment. These people may be at increased risk for environmental health problems. We studied the health status, environmental living conditions and microbial indoor air quality (IAQ) among selected groups of migrant workers and their households in Mueang District, Samut Sakhon, central Thailand. We conducted a cross sectional study of 240 migrant workers and their households randomly selected by multistage sampling. The person responsible for hygiene at each studied household was interviewed using a structured questionnaire. Two indoor air samples were taken from each household (480 indoor air samples) to determine bacterial and fungal counts using a Millipore air tester; 240 outdoor air samples were collected for comparison. Ninety-nine point six percent of study subjects were Myanmar, 74.2% were aged 21-40 years, 91.7% had a primary school level education or lower and 53.7% had stayed in Thailand less than 5 years. Eight point three percent had a history of an underlying disease, 20.8% had a recent history of pulmonary tuberculosis in a family member within the previous year. Forty-three point eight percent had a current illness related to IAQ during a previous month. Twenty-one point three were current cigarette smokers, 15.0% were current alcohol consumers, and 5.0% exercises ≥3 times per week. Forty-nine point two percent never opened the windows of their bedrooms or living rooms for ventilation, 45% never cleaned their window screens, and 38.3% never put their pillows or mattresses in the sunlight. The mean(±SD) air bacterial count was 230(±229) CFU/m3 (outdoor air = 128±82 CFU/ m3), and the mean fungal count was 630(±842) CFU/m3 (outdoor air = 138±94 CFU/ m3). When the bacterial and fungal counts were compared with the guidelines of the American Conference of Governmental Industrial Hygienists, the bacterial counts in 6.5% of houses surveyed and the fungal counts in 28.8% of house

  6. Tobacco smoke particles and indoor air quality (ToPIQ - the protocol of a new study

    Directory of Open Access Journals (Sweden)

    Mueller Daniel

    2011-12-01

    Full Text Available Abstract Environmental tobacco smoke (ETS is a major contributor to indoor air pollution. Since decades it is well documented that ETS can be harmful to human health and causes premature death and disease. In comparison to the huge research on toxicological substances of ETS, less attention was paid on the concentration of indoor ETS-dependent particulate matter (PM. Especially, investigation that focuses on different tobacco products and their concentration of deeply into the airways depositing PM-fractions (PM10, PM2.5 and PM1 must be stated. The tobacco smoke particles and indoor air quality study (ToPIQS will approach this issue by device supported generation of indoor ETS and simultaneously measurements of PM concentration by laser aerosol spectrometry. Primarily, the ToPIQ study will conduct a field research with focus on PM concentration of different tobacco products and within various microenvironments. It is planned to extend the analysis to basic research on influencing factors of ETS-dependent PM concentration.

  7. A Single Usage of a Kitchen Degreaser Can Alter Indoor Aerosol Composition for Days.

    Czech Academy of Sciences Publication Activity Database

    Schwarz, Jaroslav; Makeš, Otakar; Ondráček, Jakub; Cusack, Michael; Talbot, Nicholas; Vodička, Petr; Kubelová, Lucie; Ždímal, Vladimír

    2017-01-01

    Roč. 51, č. 11 (2017), s. 5907-5912 ISSN 0013-936X EU Projects: European Commission(XE) 315760 - HEXACOMM Institutional support: RVO:67985858 Keywords : indoor aerosol * mono- ethanol amine * aerosol transformation Subject RIV: DI - Air Pollution ; Quality OBOR OECD: Environmental sciences (social aspects to be 5.7) Impact factor: 6.198, year: 2016

  8. An RFID Indoor Positioning Algorithm Based on Bayesian Probability and K-Nearest Neighbor

    Directory of Open Access Journals (Sweden)

    He Xu

    2017-08-01

    Full Text Available The Global Positioning System (GPS is widely used in outdoor environmental positioning. However, GPS cannot support indoor positioning because there is no signal for positioning in an indoor environment. Nowadays, there are many situations which require indoor positioning, such as searching for a book in a library, looking for luggage in an airport, emergence navigation for fire alarms, robot location, etc. Many technologies, such as ultrasonic, sensors, Bluetooth, WiFi, magnetic field, Radio Frequency Identification (RFID, etc., are used to perform indoor positioning. Compared with other technologies, RFID used in indoor positioning is more cost and energy efficient. The Traditional RFID indoor positioning algorithm LANDMARC utilizes a Received Signal Strength (RSS indicator to track objects. However, the RSS value is easily affected by environmental noise and other interference. In this paper, our purpose is to reduce the location fluctuation and error caused by multipath and environmental interference in LANDMARC. We propose a novel indoor positioning algorithm based on Bayesian probability and K-Nearest Neighbor (BKNN. The experimental results show that the Gaussian filter can filter some abnormal RSS values. The proposed BKNN algorithm has the smallest location error compared with the Gaussian-based algorithm, LANDMARC and an improved KNN algorithm. The average error in location estimation is about 15 cm using our method.

  9. Towards Indoor Transportation Mode Detection using Mobile Sensing

    DEFF Research Database (Denmark)

    Prentow, Thor Siiger; Blunck, Henrik; Kjærgaard, Mikkel Baun

    2015-01-01

    Transportation mode detection is a growing field of research, in which a variety of methods have been developed for detecting transportation modes foremost for outdoor travels. It has been employed in application areas such as public transportation, environmental footprint profiling, and context......-aware mobile assistants. For indoor travels the problem of transportation mode detection has received comparatively little attention, even though diverse transportation modes, such as biking, electric vehicles, and scooters, are used indoors, especially in large building complexes. The potential applications...... are diverse, may also extend beyond indoor variants of the above outdoor applications, and include, e.g., scheduling and progress tracking for mobile workers, management of vehicular resources, and navigation support. However, for indoor transportation mode detection, both the physical environment as well...

  10. Natural indoor gamma background in Coonoor environment of South India

    International Nuclear Information System (INIS)

    Sivakumar, R.; Selvasekarapandian, S.; Mugunthamanikand, N.; Raghunath, V.M.

    2002-01-01

    Indoor natural radiation dose existing in dwellings of Coonoor have been estimated using thermoluminescent dosimeters. TLDs are displayed in indoors and are replaced after three-month period. The seasonal averages of the dose rate and the annual effective dose equivalent are calculated from the measured results. Geographical and seasonal variations as well as the differences between indoor to outdoor dose rates have also been studied. Very good correlation exists between the indoor dose rates measured by LTD and environmental radiation dosimeter with correlation coefficient of 0.91. The annual effective dose equivalent to the Coonoor population due to indoor gamma radiation was estimated to be 970 μSv/y for the period of 1997-1998. (author)

  11. Monocular Vision SLAM for Indoor Aerial Vehicles

    Directory of Open Access Journals (Sweden)

    Koray Çelik

    2013-01-01

    Full Text Available This paper presents a novel indoor navigation and ranging strategy via monocular camera. By exploiting the architectural orthogonality of the indoor environments, we introduce a new method to estimate range and vehicle states from a monocular camera for vision-based SLAM. The navigation strategy assumes an indoor or indoor-like manmade environment whose layout is previously unknown, GPS-denied, representable via energy based feature points, and straight architectural lines. We experimentally validate the proposed algorithms on a fully self-contained microaerial vehicle (MAV with sophisticated on-board image processing and SLAM capabilities. Building and enabling such a small aerial vehicle to fly in tight corridors is a significant technological challenge, especially in the absence of GPS signals and with limited sensing options. Experimental results show that the system is only limited by the capabilities of the camera and environmental entropy.

  12. Childhood asthma and indoor allergens in Native Americans in New York

    Directory of Open Access Journals (Sweden)

    Tarbell Alice

    2006-07-01

    Full Text Available Abstract Background The objective of this study was to assess the correlation between childhood asthma and potential risk factors, especially exposure to indoor allergens, in a Native American population. Methods A case-control study of St. Regis Mohawk tribe children ages 2–14 years, 25 diagnosed with asthma and 25 controls was conducted. Exposure was assessed based on a personal interview and measurement of mite and cat allergens (Der p 1, Fel d 1 in indoor dust. Results A non-significant increased risk of childhood asthma was associated with self-reported family history of asthma, childhood environmental tobacco smoke exposure, and air pollution. There was a significant protective effect of breastfeeding against current asthma in children less than 14 years (5.2 fold lower risk. About 80% of dust mite and 15% of cat allergen samples were above the threshold values for sensitization of 2 and 1 μg/g, respectively. The association between current asthma and exposure to dust mite and cat allergens was positive but not statistically significant. Conclusion This research identified several potential indoor and outdoor risk factors for asthma in Mohawks homes, of which avoidance may reduce or delay the development of asthma in susceptible individuals.

  13. Indoor tetrachloroethylene levels and determinants in Paris dwellings.

    Science.gov (United States)

    Roda, Célina; Kousignian, Isabelle; Ramond, Anna; Momas, Isabelle

    2013-01-01

    There is growing public health concern about indoor air quality. Tetrachloroethylene (PERC), a chlorinated volatile organic compound widely used as a solvent in dry cleaning facilities, can be a residential indoor air pollutant. As part of an environmental investigation included in the PARIS (Pollution and asthma Risk: an Infant Study) birth cohort, this study firstly aimed to document domestic PERC levels, and then to identify the factors influencing these levels using standardized questionnaires about housing characteristics and living conditions. Air samples were collected in the child's bedroom over one week using passive devices when infants were 1, 6, 9, and 12 months. PERC was identified and quantified by gas chromatography/mass spectrometry. PERC annual domestic level was calculated by averaging seasonal levels. PERC was omnipresent indoors, annual levels ranged from 0.6 to 124.2 μg/m3. Multivariate linear and logistic regression models showed that proximity to dry cleaning facilities, do-it-yourself activities (e.g.: photographic development, silverware), presence of air vents, and building construction date (<1945) were responsible for higher domestic levels of PERC. This study, conducted in an urban context, provides helpful information on PERC contamination in dwellings, and identifies parameters influencing this contamination. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Stojanovska, Zdenka; Janevik, Emilija; Taleski, Vaso [Goce Delcev University, Faculty of Medical Sciences, Stip (Macedonia, The Former Yugoslav Republic of); Boev, Blazo [Goce Delcev University, Faculty of Natural and Technical Sciences, Stip (Macedonia, The Former Yugoslav Republic of); Zunic, Zora S. [University of Belgrade, Institute of Nuclear Sciences ' ' Vinca' ' , Belgrade (Serbia); Ivanova, Kremena; Tsenova, Martina [National Center of Radiobiology and Radiation Protection, Sofia (Bulgaria); Ristova, Mimoza [University in Ss. Cyril and Methodius, Faculty of Natural Sciences and Mathematic, Institute of Physics, Skopje (Macedonia, The Former Yugoslav Republic of); Ajka, Sorsa [Croatian Geological Survey, Zagreb (Croatia); Bossew, Peter [German Federal Office for Radiation Protection, Berlin (Germany)

    2016-05-15

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m{sup 3} for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported. (orig.)

  15. Residential indoor air quality guideline : carbon monoxide

    International Nuclear Information System (INIS)

    2010-01-01

    Carbon monoxide (CO) is a tasteless, odourless, and colourless gas that can be produced by both natural and anthropogenic processes, but is most often formed during the incomplete combustion of organic materials. In the indoor environment, CO occurs directly as a result of emissions from indoor sources or as a result of infiltration from outdoor air containing CO. Studies have shown that the use of specific sources can lead to increased concentrations of CO indoors. This residential indoor air quality guideline examined the factors influencing the introduction, dispersion and removal of CO indoors. The health effects of exposure to low and higher concentrations of CO were discussed. Residential maximum exposure limits for CO were presented. Sources and concentrations in indoor environments were also examined. 17 refs., 2 tabs.

  16. Enhancing indoor air quality -The air filter advantage.

    Science.gov (United States)

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality.

  17. Indoor radon measurements in dwellings of Mizoram

    International Nuclear Information System (INIS)

    Lalramengzami, R.; Laldawngliana, C.; Sinha, D.; Ghosh, S.; Dwivedi, K.K.

    1995-01-01

    The concentration of indoor radon has been measured in some dwellings of Mizoram state by employing time integrated method using solid state nuclear track detector. This state is located in the north eastern region of India which has been identified as a high background area. The indoor radon levels determined in this work are compared with data obtained from other regions of India and the Environmental Protection Agency (EPA) prescribed safe limit. (author). 7 refs., 2 figs

  18. Analysis of indoor air quality data from East Tennessee field studies

    International Nuclear Information System (INIS)

    Dudney, C.S.; Hawthorne, A.R.

    1985-08-01

    This report presents the results of follow-up experimental activities and data analyses of an indoor air quality study conducted in 40 East Tennessee homes during 1982-1983. Included are: (1) additional experimental data on radon levels in all homes, repeat measurements in house No. 7 with elevated formaldehyde levels, and energy audit information on the participants' homes; (2) further data analyses, especially of the large formaldehyde data base, to ascertain relationships of pollutant levels vs environmental factors and house characteristics; (3) indoor air quality data base considerations and development of the study data base for distribution on magnetic media for both mainframe and desktop computer use; and (4) identification of design and data collection considerations for future field studies. A bibliography of additional publications related to this effort is also presented

  19. Exploring the consequences of climate change for indoor air quality

    International Nuclear Information System (INIS)

    Nazaroff, William W

    2013-01-01

    Climate change will affect the concentrations of air pollutants in buildings. The resulting shifts in human exposure may influence public health. Changes can be anticipated because of altered outdoor pollution and also owing to changes in buildings effected in response to changing climate. Three classes of factors govern indoor pollutant levels in occupied spaces: (a) properties of pollutants; (b) building factors, such as the ventilation rate; and (c) occupant behavior. Diversity of indoor conditions influences the public health significance of climate change. Potentially vulnerable subpopulations include not only the young and the infirm but also those who lack resources to respond effectively to changing conditions. Indoor air pollutant levels reflect the sum of contributions from indoor sources and from outdoor pollutants that enter with ventilation air. Pollutant classes with important indoor sources include the byproducts of combustion, radon, and volatile and semivolatile organic compounds. Outdoor pollutants of special concern include particulate matter and ozone. To ensure good indoor air quality it is important first to avoid high indoor emission rates for all pollutants and second to ensure adequate ventilation. A third factor is the use of air filtration or air cleaning to achieve further improvements where warranted. (letter)

  20. Evaluating prevalence and risk factors of building-related symptoms among office workers: Seasonal characteristics of symptoms and psychosocial and physical environmental factors.

    Science.gov (United States)

    Azuma, Kenichi; Ikeda, Koichi; Kagi, Naoki; Yanagi, U; Osawa, Haruki

    2017-04-12

    Psychosocial and environmental factors at the workplace play a significant role in building-related symptoms (BRSs). Environmental factors change during summer cooling and winter heating using air-conditioning systems. Thus, significant risk factors in each season need to be clarified. A nationwide cross-sectional study was conducted during summer in Japan and seasonal differences between summer and winter were evaluated. Self-administered questionnaires were distributed to 489 offices. Possible risk factors for BRSs associated with the work environment, indoor air quality, and job stressors were examined by multiple regression analyses. Among people having at least one BRS, the prevalence of BRSs in summer (27.8%) was slightly higher than that in winter (24.9%). High prevalence was observed for eye and nasal symptoms related to dryness and general symptoms related to psychological distress in both seasons. Analyses revealed that dryness of air was an important and significant risk factor associated with BRSs, and job stressors were significantly associated with general symptoms in both seasons. Conversely, humidity was a significant risk factor of general symptoms in summer (odds ratio, 1.20; 95% confidence interval, 1.02-1.43). Carpeting, recently painted walls, and unpleasant chemical odors in summer and noise, dust and dirt, and unpleasant odors such as body or food odors in both seasons were significant risk factors for BRSs. Improvements in the physical environmental qualities in an office throughout the year are important along with the reduction in psychological distress related to work.

  1. Investigations on indoor radon in Austria, Part 1: Seasonality of indoor radon concentration

    International Nuclear Information System (INIS)

    Bossew, Peter; Lettner, Herbert

    2007-01-01

    In general, indoor radon concentration is subject to seasonal variability. The reasons are to be found (1) in meteorological influence on the transport properties of soil, e.g. through temperature, frozen soil layers and soil water saturation; and (2) in living habits, e.g. the tendency to open windows in summer and keep them closed in winter, which in general leads to higher accumulation of geogenic Rn in closed rooms in winter. If one wants to standardize indoor Rn measurements originally performed at different times of the year, e.g. in order to make them comparable, some correction transform as a function of measurement time which accounts for these effects must be estimated. In this paper, the seasonality of indoor Rn concentration measured in Austria is investigated as a function of other factors that influence indoor Rn. Indoor radon concentration is clearly shown to have seasonal variability, with higher Rn levels in winter. However, it is complicated to quantify the effect because, as a consequence of the history of an Rn survey, the measurement season maybe correlated to geological regions, which may introduce a bias in the estimate of the seasonality amplitude

  2. Associations between multiple indoor environmental factors and clinically confirmed allergic disease in early childhood

    DEFF Research Database (Denmark)

    Callesen, Mette Buhl; Bekö, Gabriel; Weschler, Charles J.

    2012-01-01

    , rhinoconjunctivitis and atopic dermatitis. Method: A crosssectional case-cohort study (n = 500) based on 2835 children, aged 3–5 years, responding to a questionnaire, consisted of 300 subjects randomly selected and 200 cases with at least two parentally reported doctor diagnosed allergic diseases (asthma, allergic...... rhinoconjunctivitis or atopic dermatitis). The same physician conducted a clinical examination of all the 500 children including structured interview on allergic heredity, clinical and medical history. Specific s-IgE against inhalant and food allergens was determined. The homes were investigated by inspectors...... assessing air change rates, relative humidity, temperature, CO2, and dust samples were collected for analyses of indoor allergens, phthalates, nicotine and polyaromatic hydrocarbons. The diagnosis of allergic disease was based on internationally accepted criteria. Result: In the base group (n = 300) asthma...

  3. Changes to indoor air quality as a result of relocating families from slums to public housing

    Science.gov (United States)

    Burgos, Soledad; Ruiz, Pablo; Koifman, Rosalina

    2013-05-01

    One largely unstudied benefit of relocating families from slums to public housing is the potential improvement in indoor air quality (IAQ). We compared families that moved from slums to public housing with those that remained living in slums in Santiago, Chile in terms of fine particulate matter (PM2.5) as main indicator of change. A cross-sectional study of 98 relocated families and 71 still living in slums was carried out, obtaining indoor and outdoor samples by a Personal Environmental Monitor. Home characteristics, including indoor air pollution sources were collected through questionnaires. Multivariate regression models included the intervention (public housing or slum), indoor pollution sources, outdoor PM2.5 and family characteristics as predictors. Indoor PM2.5 concentrations were higher in slums (77.8 μg m-3 [SD = 35.7 μg m-3]) than in public housing (55.7 μg m-3 [SD = 34.6 μg m-3], p slum houses. The multivariate analysis showed that housing intervention significantly decreased indoor PM2.5 (10.4 μg m-3) after adjusting by the other predictors. Outdoor PM2.5 was the main predictor of indoor PM2.5. Other significant factors were water heating fuels and indoor smoking. Having infants 1-23 months was associated with a lowering of indoor PM2.5. Our results suggest that a public housing program that moves families from slums to public housing improves indoor air quality directly and also indirectly through air pollution sources.

  4. Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review.

    Science.gov (United States)

    Ai, Z T; Melikov, A K

    2018-07-01

    This article reviews past studies of airborne transmission between occupants in indoor environments, focusing on the spread of expiratory droplet nuclei from mouth/nose to mouth/nose for non-specific diseases. Special attention is paid to summarizing what is known about the influential factors, the inappropriate simplifications of the thermofluid boundary conditions of thermal manikins, the challenges facing the available experimental techniques, and the limitations of available evaluation methods. Secondary issues are highlighted, and some new ways to improve our understanding of airborne transmission indoors are provided. The characteristics of airborne spread of expiratory droplet nuclei between occupants, which are influenced correlatively by both environmental and personal factors, were widely revealed under steady-state conditions. Owing to the different boundary conditions used, some inconsistent findings on specific influential factors have been published. The available instrumentation was too slow to provide accurate concentration profiles for time-dependent evaluations of events with obvious time characteristics, while computational fluid dynamics (CFD) studies were mainly performed in the framework of inherently steady Reynolds-averaged Navier-Stokes modeling. Future research needs in 3 areas are identified: the importance of the direction of indoor airflow patterns, the dynamics of airborne transmission, and the application of CFD simulations. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Development of an indoor air quality checklist for risk assessment of indoor air pollutants by semiquantitative score in nonindustrial workplaces

    Directory of Open Access Journals (Sweden)

    Syazwan AI

    2012-04-01

    Full Text Available AI Syazwan1, B Mohd Rafee1, Juahir Hafizan2, AZF Azman1, AM Nizar3, Z Izwyn4, AA Muhaimin5, MA Syafiq Yunos6, AR Anita1, J Muhamad Hanafiah1, MS Shaharuddin1, A Mohd Ibthisham7, Mohd Hasmadi Ismail8, MN Mohamad Azhar1, HS Azizan1, I Zulfadhli9, J Othman101Department of Community Health, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Selangor, Malaysia; 2Department of Environmental Science, Faculty of Environmental Studies, Universiti Putra Malaysia, Selangor, Malaysia; 3Pharmacology Unit, Department of Human Anatomy, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Selangor, Malaysia; 4Department of Therapy and Rehabilitation, Faculty of Health Science and Biomedical Engineering, Universiti Teknologi Malaysia, Johor, Malaysia; 5Department of Environmental Management, Faculty of Environmental Studies, Universiti Putra Malaysia, Selangor, Malaysia; 6Plant Assessment Technology (PAT, Industrial Technology Division (BTI, Malaysian Nuclear Agency (Nuklear Malaysia, Bangi, Kajang, Malaysia; 7Department of Mechanical Engineering, Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, UTM Skudai, Johor, Malaysia; 8Department of Forest Production, Faculty of Forestry, Universiti Putra Malaysia, Selangor, Malaysia; 9Faculty of Built Environment and Architect, Universiti Teknologi Malaysia, Skudai, Johor, Malaysia; 10Department of Counsellor Education and Counselling Psychology (DCECP, Faculty of Educational Studies, Universiti Putra Malaysia, Selangor, MalaysiaBackground: To meet the current diversified health needs in workplaces, especially in nonindustrial workplaces in developing countries, an indoor air quality (IAQ component of a participatory occupational safety and health survey should be included.Objectives: The purpose of this study was to evaluate and suggest a multidisciplinary, integrated IAQ checklist for evaluating the health risk of building occupants. This IAQ checklist proposed to support

  6. Perceived indoor environment and occupants’ comfort in European “Modern” office buildings: The OFFICAIR Study

    NARCIS (Netherlands)

    Sakellaris, I.A.; Saraga, D.E.; Mandin, C.; Roda, C.; Fossati, S.; Kluizenaar, Y. de; Carrer, P.; Dimitroulopoulou, S.; Mihucz, V.G.; Szigeti, T.; Hänninen, O.; Oliveira Fernandes, E. de; Bartzis, J.G.; Bluyssen, P.M.

    2016-01-01

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to

  7. The effect of environmental factors on breast lumps of Egyptian women in different socioeconomic levels

    International Nuclear Information System (INIS)

    Salama, D.H.

    2008-01-01

    The environmental risk factors related to the breast tumors (lumps) are essential in order to build strategies to decrease cancer incidence and mortality among different socioeconomic and cultural backgrounds. A case control study of 70 cases and 52 controls were classified into high, middle and low socioeconomic classes. The results revealed significant increased risk of breast tumors among working females, having positive family history, married with lower mean parity, with higher consumption of fatty meals, lesser meat intake. Non significant risk factors were the social class, exposure to ionizing radiation, non lactating. wearing tight bra, consumption of vegetables and fruits, oral contraceptive pill users and exposure to outdoor air pollution or indoor pollution as floors and wall paintings. In conclusion, this study highlights the positive life style for egyptian women so they can prevent some of the environmental risks of breast tumors. Increasing the awareness of breast diseases and regular examination remains the corner stone for early detection management of breast lumps.

  8. A Self-Sustained Wireless Multi-Sensor Platform Integrated with Printable Organic Sensors for Indoor Environmental Monitoring.

    Science.gov (United States)

    Wu, Chun-Chang; Chuang, Wen-Yu; Wu, Ching-Da; Su, Yu-Cheng; Huang, Yung-Yang; Huang, Yang-Jing; Peng, Sheng-Yu; Yu, Shih-An; Lin, Chih-Ting; Lu, Shey-Shi

    2017-03-29

    A self-sustained multi-sensor platform for indoor environmental monitoring is proposed in this paper. To reduce the cost and power consumption of the sensing platform, in the developed platform, organic materials of PEDOT:PSS and PEDOT:PSS/EB-PANI are used as the sensing films for humidity and CO₂ detection, respectively. Different from traditional gas sensors, these organic sensing films can operate at room temperature without heating processes or infrared transceivers so that the power consumption of the developed humidity and the CO₂ sensors can be as low as 10 μW and 5 μW, respectively. To cooperate with these low-power sensors, a Complementary Metal-Oxide-Semiconductor (CMOS) system-on-chip (SoC) is designed to amplify and to read out multiple sensor signals with low power consumption. The developed SoC includes an analog-front-end interface circuit (AFE), an analog-to-digital convertor (ADC), a digital controller and a power management unit (PMU). Scheduled by the digital controller, the sensing circuits are power gated with a small duty-cycle to reduce the average power consumption to 3.2 μW. The designed PMU converts the power scavenged from a dye sensitized solar cell (DSSC) module into required supply voltages for SoC circuits operation under typical indoor illuminance conditions. To our knowledge, this is the first multiple environmental parameters (Temperature/CO₂/Humidity) sensing platform that demonstrates a true self-powering functionality for long-term operations.

  9. A Self-Sustained Wireless Multi-Sensor Platform Integrated with Printable Organic Sensors for Indoor Environmental Monitoring

    Directory of Open Access Journals (Sweden)

    Chun-Chang Wu

    2017-03-01

    Full Text Available A self-sustained multi-sensor platform for indoor environmental monitoring is proposed in this paper. To reduce the cost and power consumption of the sensing platform, in the developed platform, organic materials of PEDOT:PSS and PEDOT:PSS/EB-PANI are used as the sensing films for humidity and CO2 detection, respectively. Different from traditional gas sensors, these organic sensing films can operate at room temperature without heating processes or infrared transceivers so that the power consumption of the developed humidity and the CO2 sensors can be as low as 10 μW and 5 μW, respectively. To cooperate with these low-power sensors, a Complementary Metal-Oxide-Semiconductor (CMOS system-on-chip (SoC is designed to amplify and to read out multiple sensor signals with low power consumption. The developed SoC includes an analog-front-end interface circuit (AFE, an analog-to-digital convertor (ADC, a digital controller and a power management unit (PMU. Scheduled by the digital controller, the sensing circuits are power gated with a small duty-cycle to reduce the average power consumption to 3.2 μW. The designed PMU converts the power scavenged from a dye sensitized solar cell (DSSC module into required supply voltages for SoC circuits operation under typical indoor illuminance conditions. To our knowledge, this is the first multiple environmental parameters (Temperature/CO2/Humidity sensing platform that demonstrates a true self-powering functionality for long-term operations.

  10. EML indoor radon workshop, 1982

    International Nuclear Information System (INIS)

    George, A.C.; Lowder, W.; Fisenne, I.; Knutson, E.O.; Hinchliffe, L.

    1983-07-01

    A workshop on indoor radon, held at the Environmental Measurements Laboratory (EML) on November 30 and December 1, 1982, covered recent developments in radon daughter research and development. Thirty papers were presented dealing with standardization and quality assurance measurement methods, surveys, measurements strategy, physical mechanisms of radon and radon daughter transport and development of guidance standards for indoor exposures. The workshop concluded with a planning session that identified the following needs: (1) national and international intercomparisons of techniques for measuring radon and radon daughter concentrations, working level and radon exhalation flux density; (2) development and refinement of practical measurement techniques for thoron and its daughter products; (3) quantitative definition of the sources of indoor radon and the mechanisms of transport into structures; (4) better knowledge of the physical properties of radon daughters; (5) more complete and accurate data on the population exposure to radon, which can only be met by broadly based surveys; and (6) more international cooperation and information exchange among countries with major research programs

  11. Relationship between Quality of Building Maintenance Management Services for Indoor Environmental Quality and Occupant Satisfaction: Case Study of Bus Terminal Buildings in Penang

    Directory of Open Access Journals (Sweden)

    Full Chong Choon

    2014-01-01

    Full Text Available Maintenance is often defined as the series of activities undertaken to take care of the building structure and services to ensure the intended functions and optimal performance of a building life cycle. The management department of a building is usually responsible for the enhancement of the indoor environment quality by service delivery and for boosting occupant productivity and satisfaction. Thus, a salient point of this study is to determine the current level of the building’s maintenance management service for indoor environmental quality in Penang bus terminals, along with its occupant satisfaction with regards to the services provided in the building. The assessment of the indoor environmental quality includes the evaluation of thermal comfort, lighting condition, air quality and cleanliness. Apart from that, qualitative and quantitative methodologies were applied during the process of data collection and analysis. A questionnaire survey was distributed to 500 of the targeted population for each bus terminal, including passengers and the staff. In this study, the conclusion was drawn in which the maintenance management service level of the bus terminal was directly proportional to occupant satisfaction. However, the current quality of maintenance management services in the bus terminals are still not up to the level of the occupants’ satisfaction.

  12. Indoor radon seasonal variability at different floors of buildings

    International Nuclear Information System (INIS)

    De Francesco, S.; Tommasone, F. Pascale; Cuoco, E.; Tedesco, D.

    2010-01-01

    Indoor radon concentrations have been measured with the α track etch integrated method in public buildings in the town of Pietramelara, north-western Campania, Southern Italy. In particular, our measurements were part of an environmental monitoring program originally aimed at assessing the range of seasonal fluctuations in indoor radon concentrations, at various floors of the studied buildings. However, subsequent analysis of the data and its comparison with the meteorological data recorded in the same period has shown an unexpected pattern at the different floors. In this report we present data suggesting that, besides the well-known medium and longterm periodicity, there could also be a differentiation in major meteorological controlling factors at the different floors of the buildings, a fact that does not appear to have been reported previously. While the lower floors proved to be markedly affected by rainfall, for the upper floors, instead, a different behaviour has been detected, which could possibly be related to global solar radiation.

  13. 41 CFR 102-80.25 - What are Federal agencies' responsibilities concerning the management of indoor air quality?

    Science.gov (United States)

    2010-07-01

    ... agencies' responsibilities concerning the management of indoor air quality? 102-80.25 Section 102-80.25... Environmental Management Indoor Air Quality § 102-80.25 What are Federal agencies' responsibilities concerning the management of indoor air quality? Federal agencies must assess indoor air quality of buildings as...

  14. INDOOR SUBSPACING TO IMPLEMENT INDOORGML FOR INDOOR NAVIGATION

    Directory of Open Access Journals (Sweden)

    H. Jung

    2015-10-01

    Full Text Available According to an increasing demand for indoor navigation, there are great attempts to develop applicable indoor network. Representation for a room as a node is not sufficient to apply complex and large buildings. As OGC established IndoorGML, subspacing to partition the space for constructing logical network is introduced. Concerning subspacing for indoor network, transition space like halls or corridors also have to be considered. This study presents the subspacing process for creating an indoor network in shopping mall. Furthermore, categorization of transition space is performed and subspacing of this space is considered. Hall and squares in mall is especially defined for subspacing. Finally, implementation of subspacing process for indoor network is presented.

  15. Indoor Subspacing to Implement Indoorgml for Indoor Navigation

    Science.gov (United States)

    Jung, H.; Lee, J.

    2015-10-01

    According to an increasing demand for indoor navigation, there are great attempts to develop applicable indoor network. Representation for a room as a node is not sufficient to apply complex and large buildings. As OGC established IndoorGML, subspacing to partition the space for constructing logical network is introduced. Concerning subspacing for indoor network, transition space like halls or corridors also have to be considered. This study presents the subspacing process for creating an indoor network in shopping mall. Furthermore, categorization of transition space is performed and subspacing of this space is considered. Hall and squares in mall is especially defined for subspacing. Finally, implementation of subspacing process for indoor network is presented.

  16. Assessment of risk perception connected with exposure to indoor air pollution in the group of inhabitants of Silesian Voivodeship

    Directory of Open Access Journals (Sweden)

    Karolina Krupa

    2012-09-01

    Full Text Available Introduction. Population increasingly draws attention to the issues concerning the environment degraded by the progress of civilization and the impact of this process on health. However, public awareness of the risk exposure to indoor contaminants is lagging a long way behind knowledge regarding outdoor environmental hazards. The aim of the study was to assess the risk perception related to exposure to indoor environmental factors in the population of Silesia. Materials and methods. In this study the electronic version of a questionnaire survey – downloaded on the website www.moja-ankiety.pl. was used. During the 3-months duration of the project 552 subjects participated in the survey. In the study participated the Silesian Voivodeship inhabitants such as chat rooms users, newsgroups and online forum participants. Data analysis was performed by using statistical program – STATA Version 8 SE [9], where the Kruskall-Wallis test and χ2 test were applied. Statistical significance was assessed at p value *0.05. Results. Despite the low perception of environmental health hazards inside the dwellings, the majority of respondents were able to indentify health effects and ways to reduce exposure to indoor air pollution. Both gender, place of residence, education level and age significantly affected the level of perception of respondents on the risk connected with exposure to indoor air pollution. Conclusion. It is necessary to continuously work on raising public awareness of environmental health hazards in confined spaces, the causes of their occurrence, types, effects and above all the ways to counter these threats.

  17. Hospital indoor PM10/PM2.5 and associated trace elements in Guangzhou, China

    International Nuclear Information System (INIS)

    Wang Xinhua; Bi Xinhui; Sheng Guoying; Fu Jiamo

    2006-01-01

    PM10 and PM2.5 samples were collected in the indoor environments of four hospitals and their adjacent outdoor environments in Guangzhou, China during the summertime. The concentrations of 18 target elements in particles were also quantified. The results showed that indoor PM2.5 levels with an average of 99 μg m -3 were significantly higher than outdoor PM2.5 standard of 65 μg m -3 recommended by USEPA [United States Environmental Protection Agency. Office of Air and Radiation, Office of Air Quality Planning and Standards, Fact Sheet. EPA's Revised Particulate Matter Standards, 17, July 1997] and PM2.5 constituted a large fraction of indoor respirable particles (PM10) by an average of 78% in four hospitals. High correlation between PM2.5 and PM10 (R 2 of 0.87 for indoors and 0.90 for outdoors) suggested that PM2.5 and PM10 came from similar particulate emission sources. The indoor particulate levels were correlated with the corresponding outdoors (R 2 of 0.78 for PM2.5 and 0.67 for PM10), demonstrating that outdoor infiltration could lead to direct transportation into indoors. In addition to outdoor infiltration, human activities and ventilation types could also influence indoor particulate levels in four hospitals. Total target elements accounted for 3.18-5.56% of PM2.5 and 4.38-9.20% of PM10 by mass, respectively. Na, Al, Ca, Fe, Mg, Mn and Ti were found in the coarse particles, while K, V, Cr, Ni, Cu, Zn, Cd, Sn, Pb, As and Se existed more in the fine particles. The average indoor concentrations of total elements were lower than those measured outdoors, suggesting that indoor elements originated mainly from outdoor emission sources. Enrichment factors (EF) for trace element were calculated to show that elements of anthropogenic origins (Zn, Pb, As, Se, V, Ni, Cu and Cd) were highly enriched with respect to crustal composition (Al, Fe, Ca, Ti and Mn). Factor analysis was used to identify possible pollution source-types, namely street dust, road traffic and

  18. Hospital indoor PM10/PM2.5 and associated trace elements in Guangzhou, China.

    Science.gov (United States)

    Wang, Xinhua; Bi, Xinhui; Sheng, Guoying; Fu, Jiamo

    2006-07-31

    PM10 and PM2.5 samples were collected in the indoor environments of four hospitals and their adjacent outdoor environments in Guangzhou, China during the summertime. The concentrations of 18 target elements in particles were also quantified. The results showed that indoor PM2.5 levels with an average of 99 microg m(-3) were significantly higher than outdoor PM2.5 standard of 65 microg m(-3) recommended by USEPA [United States Environmental Protection Agency. Office of Air and Radiation, Office of Air Quality Planning and Standards, Fact Sheet. EPA's Revised Particulate Matter Standards, 17, July 1997] and PM2.5 constituted a large fraction of indoor respirable particles (PM10) by an average of 78% in four hospitals. High correlation between PM2.5 and PM10 (R(2) of 0.87 for indoors and 0.90 for outdoors) suggested that PM2.5 and PM10 came from similar particulate emission sources. The indoor particulate levels were correlated with the corresponding outdoors (R(2) of 0.78 for PM2.5 and 0.67 for PM10), demonstrating that outdoor infiltration could lead to direct transportation into indoors. In addition to outdoor infiltration, human activities and ventilation types could also influence indoor particulate levels in four hospitals. Total target elements accounted for 3.18-5.56% of PM2.5 and 4.38-9.20% of PM10 by mass, respectively. Na, Al, Ca, Fe, Mg, Mn and Ti were found in the coarse particles, while K, V, Cr, Ni, Cu, Zn, Cd, Sn, Pb, As and Se existed more in the fine particles. The average indoor concentrations of total elements were lower than those measured outdoors, suggesting that indoor elements originated mainly from outdoor emission sources. Enrichment factors (EF) for trace element were calculated to show that elements of anthropogenic origins (Zn, Pb, As, Se, V, Ni, Cu and Cd) were highly enriched with respect to crustal composition (Al, Fe, Ca, Ti and Mn). Factor analysis was used to identify possible pollution source-types, namely street dust, road traffic

  19. CFD model of thermal and velocity conditions in a particular indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    Mora Perez, Miguel; Lopez Patino, Gonzalo; Lopez Jimenez, P. Amparo [Hydraulic and Environmental Engineering Department, Universitat Politecnica de Valencia (Spain); Guillen Guillamon, Ignacio [Applied Physics Department, Universitat Politecnica de Valencia (Spain)

    2013-07-01

    The demand for maintaining high indoor environmental quality (IEQ) with the minimum energy consumption is rapidly increasing. In the recent years, several studies have been completed to investigate the impact of indoor environment factors on human comfort, health and energy efficiency. Therefore, the design of the thermal environment in any sort of room, specially offices, has huge economic consequences. In this paper, a particular analysis on the air temperature in a multi-task room environment is modeled, in order to represent the velocities and temperatures inside the room by using Computational Fluid Dynamics (CFD) techniques. This model will help to designers to analyze the thermal comfort regions inside the studied air volume and to visualize the whole temperatures inside the room, determining the effect of the fresh external incoming air in the internal air temperature.

  20. Climate change and health: Indoor heat exposure in vulnerable populations

    International Nuclear Information System (INIS)

    White-Newsome, Jalonne L.; Sánchez, Brisa N.; Jolliet, Olivier; Zhang, Zhenzhen; Parker, Edith A.; Timothy Dvonch, J.; O'Neill, Marie S.

    2012-01-01

    Introduction: Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods: We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 in Detroit, MI. We used mixed linear regression to model indoor temperatures' responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results: Average maximum indoor temperature for all locations was 34.85 °C, 13.8 °C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions: Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings to improve heat exposure assessment for epidemiological investigations. Weatherizing homes and modifying home surroundings could mitigate indoor heat exposure among the elderly.

  1. How indoor environment affects performance

    DEFF Research Database (Denmark)

    Wyon, David Peter; Wargocki, Pawel

    2013-01-01

    , in the form of answers to 40 frequently asked questions. Our answers are based on the results of behavioral experiments conducted to date. We offer no opinions on long-term health effects of indoor environmental quality. We provide some references to relevant sources, but there is not enough space for all...

  2. Research review: Indoor air quality control techniques

    International Nuclear Information System (INIS)

    Fisk, W.J.

    1986-10-01

    Techniques for controlling the concentration of radon, formaldehyde, and combustion products in the indoor air are reviewed. The most effective techniques, which are generally based on limiting or reducing indoor pollutant source strengths, can decrease indoor pollutant concentrations by a factor of 3 to 10. Unless the initial ventilation rate is unusually low, it is difficult to reduce indoor pollutant concentrations more than approximately 50% by increasing the ventilation rate of an entire building. However, the efficiency of indoor pollutant control by ventilation can be enhanced through the use of local exhaust ventilation near concentrated sources of pollutants, by minimizing short circuiting of air from supply to exhaust when pollutant sources are dispersed and, in some situations, by promoting a displacement flow of air and pollutants toward the exhaust. Active air cleaning is also examined briefly. Filtration and electrostatic air cleaning for removal of particles from the indoor air are the most practical and effective currently available techniques of air cleaning. 49 refs., 7 figs

  3. Health effects of indoor odorants.

    Science.gov (United States)

    Cone, J E; Shusterman, D

    1991-11-01

    People assess the quality of the air indoors primarily on the basis of its odors and on their perception of associated health risk. The major current contributors to indoor odorants are human occupant odors (body odor), environmental tobacco smoke, volatile building materials, bio-odorants (particularly mold and animal-derived materials), air fresheners, deodorants, and perfumes. These are most often present as complex mixtures, making measurement of the total odorant problem difficult. There is no current method of measuring human body odor, other than by human panel studies of expert judges of air quality. Human body odors have been quantitated in terms of the "olf" which is the amount of air pollution produced by the average person. Another quantitative unit of odorants is the "decipol," which is the perceived level of pollution produced by the average human ventilated by 10 L/sec of unpolluted air or its equivalent level of dissatisfaction from nonhuman air pollutants. The standard regulatory approach, focusing on individual constituents or chemicals, is not likely to be successful in adequately controlling odorants in indoor air. Besides the current approach of setting minimum ventilation standards to prevent health effects due to indoor air pollution, a standard based on the olf or decipol unit might be more efficacious as well as simpler to measure.

  4. Assessment of indoor environment of buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Y.; Kovanen, K. [VTT Building Technology, Espoo (Finland). Indoor Environment and Systems

    1995-12-31

    The synthetical assessment of indoor environment has become world-wide topic in recent years. Many research evidences have shown that the quality of indoor air is a multi-factor influenced issue. Building Research Establishment (BRE) in United Kingdom has worked out a series of assessing methods for different kinds of buildings. Whereas, in Finland, National Building Code of Finland has been used for many years. The comparison between the two approaches in assessing indoor air quality will be addressed in this presentation. Each issue considered in the above two approaches is discussed by referring the recent research highlights. (author)

  5. Assessment of indoor environment of buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Y; Kovanen, K [VTT Building Technology, Espoo (Finland). Indoor Environment and Systems

    1996-12-31

    The synthetical assessment of indoor environment has become world-wide topic in recent years. Many research evidences have shown that the quality of indoor air is a multi-factor influenced issue. Building Research Establishment (BRE) in United Kingdom has worked out a series of assessing methods for different kinds of buildings. Whereas, in Finland, National Building Code of Finland has been used for many years. The comparison between the two approaches in assessing indoor air quality will be addressed in this presentation. Each issue considered in the above two approaches is discussed by referring the recent research highlights. (author)

  6. Nordic interdisciplinary reviews of the scientific literature concerning the relationsiip between indoor environmental factors and health, Nordworks

    DEFF Research Database (Denmark)

    Sundell, Jan; Bornehag, C.-G.

    1999-01-01

    The relationship between indoor air environments and health is, however, a truly interdisciplinary area involving numerous disciplines. Scientific work is primarily "within disciplinary", often resulting in conclusions that would not stand in an interdisciplinary context. Results are mostly...... today, a number of interdisciplinary scientific groups have been created within the Nordic countries with the aim at reviewing the scientific literature within specific areas, and creating an interdisciplinary consensus on the present state of the art. Results from four so-called NORD-groups (NORDVOC...

  7. Respiratory Effects of Indoor Heat and the Interaction with Air Pollution in Chronic Obstructive Pulmonary Disease.

    Science.gov (United States)

    McCormack, Meredith C; Belli, Andrew J; Waugh, Darryn; Matsui, Elizabeth C; Peng, Roger D; Williams, D'Ann L; Paulin, Laura; Saha, Anik; Aloe, Charles M; Diette, Gregory B; Breysse, Patrick N; Hansel, Nadia N

    2016-12-01

    There is limited evidence of the effect of exposure to heat on chronic obstructive pulmonary disease (COPD) morbidity, and the interactive effect between indoor heat and air pollution has not been established. To determine the effect of indoor and outdoor heat exposure on COPD morbidity and to determine whether air pollution concentrations modify the effect of temperature. Sixty-nine participants with COPD were enrolled in a longitudinal cohort study, and data from the 601 participant days that occurred during the warm weather season were included in the analysis. Participants completed home environmental monitoring with measurement of temperature, relative humidity, and indoor air pollutants and simultaneous daily assessment of respiratory health with questionnaires and portable spirometry. Participants had moderate to severe COPD and spent the majority of their time indoors. Increases in maximal indoor temperature were associated with worsening of daily Breathlessness, Cough, and Sputum Scale scores and increases in rescue inhaler use. The effect was detected on the same day and lags of 1 and 2 days. The detrimental effect of temperature on these outcomes increased with higher concentrations of indoor fine particulate matter and nitrogen dioxide (P pollution concentrations. For patients with COPD who spend the majority of their time indoors, indoor heat exposure during the warmer months represents a modifiable environmental exposure that may contribute to respiratory morbidity. In the context of climate change, adaptive strategies that include optimization of indoor environmental conditions are needed to protect this high-risk group from the adverse health effects of heat.

  8. Indoor Heating Drives Water Bacterial Growth and Community Metabolic Profile Changes in Building Tap Pipes during the Winter Season.

    Science.gov (United States)

    Zhang, Hai-Han; Chen, Sheng-Nan; Huang, Ting-Lin; Shang, Pan-Lu; Yang, Xiao; Ma, Wei-Xing

    2015-10-27

    The growth of the bacterial community harbored in indoor drinking water taps is regulated by external environmental factors, such as indoor temperature. However, the effect of indoor heating on bacterial regrowth associated with indoor drinking water taps is poorly understood. In the present work, flow cytometry and community-level sole-carbon-source utilization techniques were combined to explore the effects of indoor heating on water bacterial cell concentrations and community carbon metabolic profiles in building tap pipes during the winter season. The results showed that the temperature of water stagnated overnight ("before") in the indoor water pipes was 15-17 °C, and the water temperature decreased to 4-6 °C after flushing for 10 min ("flushed"). The highest bacterial cell number was observed in water stagnated overnight, and was 5-11 times higher than that of flushed water. Meanwhile, a significantly higher bacterial community metabolic activity (AWCD590nm) was also found in overnight stagnation water samples. The significant "flushed" and "taps" values indicated that the AWCD590nm, and bacterial cell number varied among the taps within the flushed group (p heating periods.

  9. ASSOCIATIONS BETWEEN SEASONAL SLEEP CHANGE AND INDOOR TANNING1,2

    OpenAIRE

    CULNAN, ELIZABETH; KLOSS, JACQUELINE D.; DARLOW, SUSAN; HECKMAN, CAROLYN J.

    2015-01-01

    Identification of risk factors for indoor tanning may ultimately aid the development of better indoor tanning prevention strategies, which is pertinent given the association between indoor tanning and skin cancer. This study aimed to examine the relationship between seasonal sleep change and indoor tanning. Women tanners (N= 139) completed self-report measures including items relating to seasonal sleep changes, seasonal affective disorder (SAD), reasons for tanning, tanning during the winter ...

  10. Geologic factors and house construction practices affecting indoor radon in Onondaga County, New York

    International Nuclear Information System (INIS)

    Laymon, C.; Kunz, C.

    1990-01-01

    Indoor radon in Onondaga County, New York is largely controlled by bedrock and surficial geology. At more local scales, these alone are insufficient to characterize indoor radon potential. This paper reports on a detailed study of the concentration of indoor radon, soil radium, soil-gas radon, soil and bedrock type, permeability, and home construction practices indicates that above-average indoor radon concentrations are associated with gravelly moraine and glaciofluvial deposits, the radium-bearing Marcellus Shale, and high permeability zones around the substructure of houses built into limestone bedrock

  11. Effect of Sex and Body Mass Index on Children's Physical Activity Intensity during Free Play at an Indoor Soft Play Center: An Exploratory Study.

    Science.gov (United States)

    Jones, Michelle A

    2017-09-12

    Background : Indoor soft play can provide a safe but exciting physical activity opportunity regardless of environmental conditions. Relatively little is known about the quality or quantity of physical activity engaged in by children during indoor free soft play. The aim of this study was to evaluate the contribution indoor free soft play can make in enabling children to meet physical activity guidelines and to evaluate the effects of sex and body mass index category. Methods : Seventy-two boys and girls aged five to 10 years engaged in un-controlled indoor free soft play with a mean duration of 120.7 (27.1) min, during which physical activity was monitored using Actigraph accelerometers. Results : Children spent an average of 61.7 (24.2) min engaging in moderate to vigorous physical activity (MVPA) and 51.4% ( n = 37) achieved the recommended 60 min of MVPA through the single visit to the indoor soft play center. Boys (68.3 (25.7) min) engaged in significantly ( p < 0.05) more MVPA than girls (55.8 (21.4) min). Normal weight (65.7 (23.3) min) children engaged in significantly more MVPA than overweight children (48.0 (18.9) min). Conclusions : Attendance at a soft play indoor center has the potential to support children to engage in sufficient MVPA and overcome environmental factors that can restrict physical activity opportunities.

  12. Fast Fingerprint Database Maintenance for Indoor Positioning Based on UGV SLAM

    Directory of Open Access Journals (Sweden)

    Jian Tang

    2015-03-01

    Full Text Available Indoor positioning technology has become more and more important in the last two decades. Utilizing Received Signal Strength Indicator (RSSI fingerprints of Signals of OPportunity (SOP is a promising alternative navigation solution. However, as the RSSIs vary during operation due to their physical nature and are easily affected by the environmental change, one challenge of the indoor fingerprinting method is maintaining the RSSI fingerprint database in a timely and effective manner. In this paper, a solution for rapidly updating the fingerprint database is presented, based on a self-developed Unmanned Ground Vehicles (UGV platform NAVIS. Several SOP sensors were installed on NAVIS for collecting indoor fingerprint information, including a digital compass collecting magnetic field intensity, a light sensor collecting light intensity, and a smartphone which collects the access point number and RSSIs of the pre-installed WiFi network. The NAVIS platform generates a map of the indoor environment and collects the SOPs during processing of the mapping, and then the SOP fingerprint database is interpolated and updated in real time. Field tests were carried out to evaluate the effectiveness and efficiency of the proposed method. The results showed that the fingerprint databases can be quickly created and updated with a higher sampling frequency (5Hz and denser reference points compared with traditional methods, and the indoor map can be generated without prior information. Moreover, environmental changes could also be detected quickly for fingerprint indoor positioning.

  13. Assessing future trends in indoor air quality

    International Nuclear Information System (INIS)

    van de Wiel, H.J.; Lebret, E.; van der Lingen, W.K.; Eerens, H.C.; Vaas, L.H.; Leupen, M.J.

    1990-01-01

    Several national and international health organizations have derived concentration levels below which adverse effects on men are not expected or levels below which the excess risk for individuals is less than a specified value. For every priority pollutant indoor concentrations below this limit are considered healthy. The percentage of Dutch homes exceeding such a limit is taken as a measure of indoor air quality for that component. The present and future indoor air quality of the Dutch housing stock is described for fourteen air pollutants. The highest percentages are scored by radon, environmental tobacco smoke, nitrogen dioxide from unvented combustion, and the potential presence of housedust mite and mould allergen in damp houses. Although the trend for all priority pollutants is downward the most serious ones remain high in the coming decades if no additional measures will be instituted

  14. Conference particulate matter and indoor environment, I.N.E.R.I.S.; Particulate matter and indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    Comprehensive characterisation of indoor and outdoor air as well as pollution emission sources Integrated health and environmental risk assessment Scientific and technical basis for airborne pollution management and control Fine and coarse particles. The sources of indoor air pollution are originate separately, are transported separately, are removed from atmosphere by different mechanisms, have different optical properties, have different chemical properties, require different control techniques. for the health effects due to particles, they decrease the lung function, increase respiratory symptoms, increase chronic obstructive pulmonary diseases, increased cardiovascular disease, increased mortality. The different sources contributing to the highest concentrations are: concentrations: tobacco smoking, cooking, vacuuming, dusting and sweeping, heaters, stoves, fireplaces and some other non identified sources. In the future we want more focus on fine and ultra fine particles, investigate source apportionment of particles, better understanding and quantification of exposure, to implement guidelines for particle concentration in indoor air and find better cleaning technologies. (N.C.)

  15. Quantitative relationships between occupant satisfaction and satisfaction aspects of indoor environmental quality and building design.

    Science.gov (United States)

    Frontczak, M; Schiavon, S; Goins, J; Arens, E; Zhang, H; Wargocki, P

    2012-04-01

    The article examines which subjectively evaluated indoor environmental parameters and building features mostly affect occupants' satisfaction in mainly US office buildings. The study analyzed data from a web-based survey administered to 52,980 occupants in 351 office buildings over 10 years by the Center for the Built Environment. The survey uses 7-point ordered scale questions pertaining to satisfaction with indoor environmental parameters, workspace, and building features. The average building occupant was satisfied with his/her workspace and building. Proportional odds ordinal logistic regression shows that satisfaction with all 15 parameters listed in the survey contributed significantly to overall workspace satisfaction. The most important parameters were satisfaction with amount of space (odds ratio OR 1.57, 95% CI: 1.55-1.59), noise level (OR 1.27, 95% CI: 1.25-1.29), and visual privacy (OR 1.26, 95% CI: 1.24-1.28). Satisfaction with amount of space was ranked to be most important for workspace satisfaction, regardless of age group (below 30, 31-50 or over 50 years old), gender, type of office (single or shared offices, or cubicles), distance of workspace from a window (within 4.6 m or further), or satisfaction level with workspace (satisfied or dissatisfied). Satisfaction with amount of space was not related to the gross amount of space available per person. To maximize workspace satisfaction, designer should invest in aspects that increase satisfaction with amount of space and storage, noise level, and visual privacy. Office workers will be most satisfied with their workspace and building when located close to a window in a private office. This may affect job satisfaction, work performance, and personal and company productivity. © 2011 John Wiley & Sons A/S.

  16. Indoor household pesticides: hazardous waste concern or not?

    Science.gov (United States)

    Owens, J M; Guiney, P D; Howard, P H; Aronson, D B; Gray, D A

    2000-01-01

    Many indoor household pesticides are efficient and useful tools for a variety of functions necessary to maintain clean, sanitary, and pleasant homes and institutional facilities, and to provide significant public health benefits. They do so by incorporating active ingredients and formulation technology that have not been associated with significant environmental impact in use or when disposed in landfills. Chemical and environmental fate properties, toxicological characteristics, and use patterns of indoor household pesticides that distinguish them from other categories of pesticides which have been associated with environmental contamination should be recognized when HHW policy is debated and established by governmental agencies. Most indoor household pesticides as defined here should not be considered hazardous waste or HHW because those relatively few containers, often no longer full, that have been disposed with MSW over the years have not been associated with environmental contamination. The tiny amounts of those product residues that will reach MSW landfills have been shown, in general, not to have chemical or environmental fate characteristics that would make them susceptible to leaching. Those that do have the potential to leach based on these characteristics, in most cases, do not represent a threat to human health based on toxicological considerations. However, compounds such as propoxur, which are very mobile and relatively persistent in soil and in addition have been associated with significant potential health effects, may be targeted by the screening process as described here and could be selected for further investigation as candidates for special waste management status (such as HHW). Our analysis and recommendations have not been extended to the many types of lawn and garden pesticides that are commonly used by homeowners and are frequently brought to HHW programs. However, their potential for groundwater contamination could also be judged using

  17. Development of a model to calculate the economic implications of improving the indoor climate

    DEFF Research Database (Denmark)

    Jensen, Kasper Lynge

    on performance. The Bayesian Network uses a probabilistic approach by which a probability distribution can take this variation of the different indoor variables into account. The result from total building economy calculations indicated that depending on the indoor environmental change (improvement...

  18. Effect of Sex and Body Mass Index on Children’s Physical Activity Intensity during Free Play at an Indoor Soft Play Center: An Exploratory Study

    Science.gov (United States)

    2017-01-01

    Background: Indoor soft play can provide a safe but exciting physical activity opportunity regardless of environmental conditions. Relatively little is known about the quality or quantity of physical activity engaged in by children during indoor free soft play. The aim of this study was to evaluate the contribution indoor free soft play can make in enabling children to meet physical activity guidelines and to evaluate the effects of sex and body mass index category. Methods: Seventy-two boys and girls aged five to 10 years engaged in un-controlled indoor free soft play with a mean duration of 120.7 (27.1) min, during which physical activity was monitored using Actigraph accelerometers. Results: Children spent an average of 61.7 (24.2) min engaging in moderate to vigorous physical activity (MVPA) and 51.4% (n = 37) achieved the recommended 60 min of MVPA through the single visit to the indoor soft play center. Boys (68.3 (25.7) min) engaged in significantly (p < 0.05) more MVPA than girls (55.8 (21.4) min). Normal weight (65.7 (23.3) min) children engaged in significantly more MVPA than overweight children (48.0 (18.9) min). Conclusions: Attendance at a soft play indoor center has the potential to support children to engage in sufficient MVPA and overcome environmental factors that can restrict physical activity opportunities. PMID:28895904

  19. A Single-Stage LED Tube Lamp Driver with Power-Factor Corrections and Soft Switching for Energy-Saving Indoor Lighting Applications

    Directory of Open Access Journals (Sweden)

    Chun-An Cheng

    2017-01-01

    Full Text Available This paper presents a single-stage alternating current (AC/direct current (DC light-emitting diode (LED tube lamp driver for energy-saving indoor lighting applications; this driver features power-factor corrections and soft switching, and also integrates a dual buck-boost converter with coupled inductors and a half-bridge series resonant converter cascaded with a bridge rectifier into a single-stage power-conversion topology. The features of the presented driver are high efficiency (>91%, satisfying power factor (PF > 0.96, low input-current total-harmonic distortion (THD < 10%, low output voltage ripple factor (<7.5%, low output current ripple factor (<8%, and zero-voltage switching (ZVS obtained on both power switches. Operational principles are described in detail, and experimental results obtained from an 18 W-rated LED tube lamp for T8/T10 fluorescent lamp replacements with input utility-line voltages ranging from 100 V to 120 V have demonstrated the functionality of the presented driver suitable for indoor lighting applications.

  20. Indoor environmental quality (IEQ) of school classrooms: Case study in Malaysia

    Science.gov (United States)

    Samad, Muna Hanim Abdul; Aziz, Zalena Abdul; Isa, Mohd Hafizal Mohd

    2017-10-01

    Thermal Comfort is one of the key criteria for occupants' comfort and productivity in a building. In schools, it is vital for a conduciveness for teaching and learning environment. Thermal comfort is dependent on air temperature, humidity, radiation, internal lighting, air movement, activities, clothing and climatic change and is part of the Indoor Environmental Quality (IEQ) components which have has significant effects on occupants. The main concern over energy and running cost has meant that most public schools in Malaysia are designed for natural ventilation and not air-conditioning. The building envelope plays a significant role in reducing the radiant heat and keeps the interior cooler than the outdoor temperature for acceptable thermal comfort level. The requirement of Industrial Building System (IBS) as the envelope system for school building in Malaysia could affect the role of envelope as a climate moderator. This paper is based on a research conducted on two schools in Malaysia of varied construction materials as the building envelopes to ascertain the thermal comfort level of the classrooms. Elements of IEQ such as air temperature, air movement, daylighting and noise level were taken of various classrooms to fulfill the required objectives of determining the level of quality. The data collected and analysed from the study shows that in terms of air temperature which range from 28°C to 34.5°C, the schools do not achieve the recommended comfort level for tropical climate. As for daylighting element, results also show that some classrooms suffered with too much glare whilst others had insufficient daylighting. The findings also show the unsatisfactory level of air movement in the classrooms as well as an unacceptable noise level exceeding the allowable threshold. This research also concluded that the use of materials and orientation in the school design are the major determinant factors towards good IEQ levels in school buildings.

  1. Indoor air pollution

    International Nuclear Information System (INIS)

    Qureshi, I.H.

    2001-01-01

    Indoor air pollution is a potential risk to human health. Prolonged exposure to indoor pollutants may cause various infectious, allergic and other diseases. Indoor pollutants can emanate from a broad array of internal and external sources. Internal sources include building and furnishing materials, consumer and commercial products, office equipment, micro-organisms, pesticides and human occupants activities. External sources include soil, water supplies and outside makeup air. The main indoor air pollutants of concern are inorganic gases, formaldehyde and other volatile organic compounds, pesticides, radon and its daughters, particulates and microbes. The magnitude of human exposure to indoor pollutants can be estimated or predicted with the help of mathematical models which have been developed using the data from source emission testing and field monitoring of pollutants. In order to minimize human exposure to indoor pollutants, many countries have formulated guidelines / standards for the maximum permissible levels of main pollutants. Acceptable indoor air quality can be achieved by controlling indoor pollution sources and by effective ventilation system for removal of indoor pollutants. (author)

  2. Indoor Radon and Its Decay Products: Concentrations, Causes, and Control Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nero, A.V.; Gadgil, A.J.; Nazaroff, W.W.; Revzan, K.L.

    1990-01-01

    This report is an introduction to the behavior of radon 222 and its decay products in indoor air. This includes review of basic characteristics of radon and its decay products and of features of the indoor environment itself, all of which factors affect behavior in indoor air. The experimental and theoretical evidence on behavior of radon and its decay products is examined, providing a basis for understanding the influence of geological, structural, and meteorological factors on indoor concentrations, as well as the effectiveness of control techniques. We go on to examine three important issues concerning indoor radon. We thus include (1) an appraisal of the concentration distribution in homes, (2) an examination of the utility and limitations of popular monitoring techniques and protocols, and (3) an assessment of the key elements of strategies for controlling radon levels in homes.

  3. In search of a common European approach to a healthy indoor environment

    DEFF Research Database (Denmark)

    Adan, Olaf C G; Ng-A-Tham, Julie; Hanke, Wojtek

    2007-01-01

    Increasingly, policymakers in Europe and around the world are realizing the importance of healthy indoor environments for public health. Certain member states of the European Union (EU) have already achieved successes in improving indoor environmental quality, such as controlling certain...... barriers: a) the subsidiarity principle in EU policymaking, introducing decentralization of decision making to the member states; b) fragmentation of the topic of the indoor environment; c) the differences in climate and governance among different member states that make a common policy difficult; and d...

  4. Indoor and Outdoor Levels and Sources of Submicron Particles (PM1) at Homes in Edmonton, Canada.

    Science.gov (United States)

    Bari, Md Aynul; Kindzierski, Warren B; Wallace, Lance A; Wheeler, Amanda J; MacNeill, Morgan; Héroux, Marie-Ève

    2015-06-02

    Exposure to submicron particles (PM1) is of interest due to their possible chronic and acute health effects. Seven consecutive 24-h PM1 samples were collected during winter and summer 2010 in a total of 74 nonsmoking homes in Edmonton, Canada. Median winter concentrations of PM1 were 2.2 μg/m(3) (interquartile range, IQR = 0.8-6.1 μg/m(3)) and 3.3 μg/m(3) (IQR = 1.5-6.9 μg/m(3)) for indoors and outdoors, respectively. In the summer, indoor (median 4.4 μg/m(3), IQR = 2.4-8.6 μg/m(3)) and outdoor (median 4.3 μg/m(3), IQR = 2.6-7.4 μg/m(3)) levels were similar. Positive matrix factorization (PMF) was applied to identify and apportion indoor and outdoor sources of elements in PM1 mass. Nine sources contributing to both indoor and outdoor PM1 concentrations were identified including secondary sulfate, soil, biomass smoke and environmental tobacco smoke (ETS), traffic, settled and mixed dust, coal combustion, road salt/road dust, and urban mixture. Three additional indoor sources were identified i.e., carpet dust, copper-rich, and silver-rich. Secondary sulfate, soil, biomass smoke and ETS contributed more than 70% (indoors: 0.29 μg/m(3), outdoors: 0.39 μg/m(3)) of measured elemental mass in PM1. These findings can aid understanding of relationships between submicron particles and health outcomes for indoor/outdoor sources.

  5. Environmental and Personal Factors Related to Asthma Severity among Children: Hospital Based Study, Egypt

    Directory of Open Access Journals (Sweden)

    Omaima Ibrahim AboElkheir

    2016-09-01

    Full Text Available Background: Childhood asthma is a complex disorder in which many environmental and personal factors play a role. However, the contribution of these factors to asthma severity is poorly understood. This study aims to determine the relationship between environmental exposures, personal factors and asthma severity among asthmatic children. Methods: This cross-sectional hospital based study was conducted on 180 asthmatic children; they were divided into mild, moderate and severe asthma according to forced expiratory volume in first second. Environmental factors (indoor and outdoor, food allergy, history of other allergic diseases, family history of allergic disorders, time trend of attacks as well as asthma outcome were reported. Results: Children with severe asthma were younger than those with mild or moderate asthma. Severe asthma was significantly linked to family history of allergy, presence of co-morbid allergic diseases, fish, egg and milk allergy, as well as exposure to passive smoking (73.7% and poor housing conditions. Also, it was significantly linked to presence of unauthorized factories in residential area (31.6 %, p=0.001. As well as, contact with pets (42.1%. Children with severe asthma had more limitations of physical activities (73.7%, missed school days (81.5%, with poor school performance (p=0.04 than those with mild moderate or asthma. Conclusion: Severe asthma was linked to female gender and younger age, co-morbid allergic diseases, family history of atopy and food allergy. It was higher among children residing in places with unauthorized factories and living in substandard housing condition. Children with severe asthma had poor asthma outcome.

  6. Design and Development of a Nearable Wireless System to Control Indoor Air Quality and Indoor Lighting Quality

    Directory of Open Access Journals (Sweden)

    Francesco Salamone

    2017-05-01

    Full Text Available The article describes the results of the project “open source smart lamp” aimed at designing and developing a smart object able to manage and control the indoor environmental quality (IEQ of the built environment. A first version of this smart object, built following a do-it-yourself (DIY approach using a microcontroller, an integrated temperature and relative humidity sensor, and techniques of additive manufacturing, allows the adjustment of the indoor thermal comfort quality (ICQ, by interacting directly with the air conditioner. As is well known, the IEQ is a holistic concept including indoor air quality (IAQ, indoor lighting quality (ILQ and acoustic comfort, besides thermal comfort. The upgrade of the smart lamp bridges the gap of the first version of the device providing the possibility of interaction with the air exchange unit and lighting system in order to get an overview of the potential of a nearable device in the management of the IEQ. The upgraded version was tested in a real office equipped with mechanical ventilation and an air conditioning system. This office was occupied by four workers. The experiment is compared with a baseline scenario and the results show how the application of the nearable device effectively optimizes both IAQ and ILQ.

  7. Perceived Indoor Environment and Occupants' Comfort in European "Modern" Office Buildings: The OFFICAIR Study.

    Science.gov (United States)

    Sakellaris, Ioannis A; Saraga, Dikaia E; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G; Bluyssen, Philomena M

    2016-04-25

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers' comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants' comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 "modern" office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants' comfort. The highest association with occupants' overall comfort was found for "noise", followed by "air quality", "light" and "thermal" satisfaction. Analysis of detailed parameters revealed that "noise inside the buildings" was highly associated with occupants' overall comfort. "Layout of the offices" was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building's location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.

  8. Factors affecting yearly variations of indoor radon concentrations

    International Nuclear Information System (INIS)

    Steck, D.J.; Baynes, S.A.

    1996-01-01

    Since indoor radon exposures take place over many years while radon measurement periods are shorter, we are studying the yearly variation of indoor radon concentrations in approximately 100 houses located throughout Minnesota. Most houses were initially measured for one or more years in the late 1980's and for 5 consecutive years starting in 1990. Two houses have been monitored for 12 y. Each year, two alpha track detectors were placed on the two lowest livable levels. The year-to-year variations averaged about 35% (corrected for instrumental uncertainties) in both basements and first floors. The minimum observed variation was 5% and the maximum was 130%. Some homes have shown substantial variation associated with Structural modifications. While most homes show no obvious systematic trends, a few houses have shown temporal trends that may be associated with aging or climate. We are studying possible correlation between year-to-year radon variation, climatic variables (yearly-average and seasonal such as heating/cooling degree days, precipitation, soil moisture), and structural changes

  9. Report on HVAC option selections for a relocatable classroom energy and indoor environmental quality field study; TOPICAL

    International Nuclear Information System (INIS)

    Apte, Michael G.; Delp, Woody W.; Diamond, Richard C.; Hodgson, Alfred T.; Kumar, Satish; Rainer, Leo I.; Shendell, Derek G.; Sullivan, Doug P.; Fisk, William J.

    2001-01-01

    It is commonly assumed that efforts to simultaneously develop energy efficient building technologies and to improve indoor environmental quality (IEQ) are unfeasible. The primary reason for this is that IEQ improvements often require additional ventilation that is costly from an energy standpoint. It is currently thought that health and productivity in work and learning environments requires adequate, if not superior, IEQ. Despite common assumptions, opportunities do exist to design building systems that provide improvements in both energy efficiency and IEQ. This report outlines the selection of a heating, ventilation, and air conditioning (HVAC) system to be used in demonstrating such an opportunity in a field study using relocatable school classrooms. Standard classrooms use a common wall mounted heat pump HVAC system. After reviewing alternative systems, a wall-mounting indirect/direct evaporative cooling system with an integral hydronic gas heating is selected. The anticipated advantages of this system include continuous ventilation of 100 percent outside air at or above minimum standards, projected cooling energy reductions of about 70 percent, inexpensive gas heating, improved airborne particle filtration, and reduced peak load electricity use. Potential disadvantages include restricted climate regions and possible increases in indoor relative humidity levels under some conditions

  10. Environmental Factors and Cardiovascular Diseases

    Directory of Open Access Journals (Sweden)

    Omer Faruk Tekbas

    2008-10-01

    Full Text Available Epidemiological and clinical observations have led to the hypothesis that the risk of developing cardiovascular diseases is influenced not only by genetic, lifestyle and major risk factors, but also by environmental factors. Environmental factors are considered key determinants of cardiovascular diseases. Although lifestyle choices such as smoking, diet, and exercise are viewed as major environmental influences, the contribution of pollutants and environmental chemicals is less clear. Accumulating evidence suggests that exposure to physically and chemical pollutants could elevate the risk of cardiovascular diseases. Many epidemiological studies report that exposure to physically, biologically and socio-cultural environmental factors are associated with an increase in cardiovascular mortality. Relationships between environmental factors and coronary arter disease, arhythmias, and cardiomyopathies have been reported. Exposures to arsenic, lead, cadmium, pollutant gases, solvents, and pesticides have also been linked to increased incidence of cardiovascular disease. In this paper, I review that relationships between exposure to physically, chemical, biologically and socio-cultural environmental factors and cardiovascular diseases. [TAF Prev Med Bull 2008; 7(5.000: 435-444

  11. A 2-year study of seasonal indoor radon variations in northern Virginia

    International Nuclear Information System (INIS)

    Mose, D.G.; Mushrush, G.W.; Chrosniak, C.E.

    1991-01-01

    The concentrations of indoor radon in the basements of homes located in northern Virginia average about 1.4 times the first-floor radon concentrations. Basement indoor radon concentrations exhibit seasonal variations that can be related to home use patterns of the occupants. Little indoor radon difference was seen between homes that have concrete block basement walls and poured concrete basement walls, but homes that use oil or gas furnaces for heating have ∼ 25% lower indoor radon than homes that use electrical heating systems. Particular geological units seem to be associated with elevated indoor radon concentrations, and several units are associated with indoor radon concentrations that exceed 4 pCi/l (the U.S. Environmental Agency action level) at some time in more than 40% of the homes. Comparative studies between indoor radon and total gamma aeroradioactivity show that aeroradioactivity can be accurately used to estimate community radon hazards. When combined with information about the home heating system, geology and aeroradioactivity can be used to identify problem homes

  12. Size specific indoor aerosol deposition measurements and derived I/O concentrations ratios

    DEFF Research Database (Denmark)

    Fogh, C.L.; Byrne, M.A.; Roed, Jørn

    1997-01-01

    The process of aerosol deposition on indoor surfaces has implications for human exposure to particulate contaminants of both indoor and outdoor origin. In the radiological context, current accident models assume a uniform Dose Reduction Factor (DRF) of 0.5 for indoor residence during the outdoor...

  13. Environmental and indoor study of Radon concentration in San Joaquin area, Queretaro, Mexico, first results

    International Nuclear Information System (INIS)

    Hinojo Alonso, N.A.; Kotsarenko, A.; Yutsis, V.; Hernandez Silva, G.; Perego, P.; Fazio, M.; Grimalsky, V.; Koshevaya, S.; Foglia, F.; Cortes Silva, A.; García Martínez, R.; Martínez Reyes, J.; Norini, G.; Groppelli, G.

    2013-01-01

    A highly contaminated zone with a maximum over 57,000 Bq/m 3 was discovered in a populated community “Agua de Venados” during the 2009–2011 soil Radon survey in San Joaquin, Queretaro State, Mexico. The indoor Radon monitoring accomplished in 2 different époques in a nearby 4 dwellings has shown an increased Radon hazard in 1 of the 4 buildings (about 300 Bq/m 3 ) during a rainy season and highly elevated indoor Radon levels (over 400 Bq/m 3 ) already in 3 buildings during a dry season. The averaged diurnal indoor Radon variations are in a correlation with the atmospheric pressure and the air humidity and are independent on the air temperature. The maximum indoor Radon hazard for dwellings is estimated for the morning interval 5–10 a.m. - Highlights: ► Emanative zone of 57,000 Bq/m 3 was found in area “Agua de Venados”. ► Indoor Radon level in a nearby dwellings elevates during a dry season. ► Maximum risk for residents was estimated during the daily interval 5–10 a.m

  14. Indoor Chemistry

    DEFF Research Database (Denmark)

    Weschler, Charles J.; Carslaw, Nicola

    2018-01-01

    This review aims to encapsulate the importance, ubiquity, and complexity of indoor chemistry. We discuss the many sources of indoor air pollutants and summarize their chemical reactions in the air and on surfaces. We also summarize some of the known impacts of human occupants, who act as sources...... and sinks of indoor chemicals, and whose activities (e.g., cooking, cleaning, smoking) can lead to extremely high pollutant concentrations. As we begin to use increasingly sensitive and selective instrumentation indoors, we are learning more about chemistry in this relatively understudied environment....

  15. Passive Methods as a Solution for Improving Indoor Environments

    CERN Document Server

    Orosa, José A

    2012-01-01

    There are many aspects to consider when evaluating or improving an indoor environment; thermal comfort, energy saving, preservation of materials, hygiene and health are all key aspects which can be improved by passive methods of environmental control. Passive Methods as a Solution for Improving Indoor Environments endeavours to fill the lack of analysis in this area by using over ten years of research to illustrate the effects of methods such as thermal inertia and permeable coverings; for example, the use of permeable coverings is a well known passive method, but its effects and ways to improve indoor environments have been rarely analyzed.   Passive Methods as a Solution for Improving Indoor Environments  includes both software simulations and laboratory and field studies. Through these, the main parameters that characterize the behavior of internal coverings are defined. Furthermore, a new procedure is explained in depth which can be used to identify the real expected effects of permeable coverings such ...

  16. Waste-based materials; capability, application and impact on indoor environment – literature review

    DEFF Research Database (Denmark)

    Krejcirikova, Barbora; Rode, Carsten; Kolarik, Jakub

    2014-01-01

    This paper reviews and discusses various sustainable materials utilizing waste products with the focus on their properties having an impact on the indoor environmental conditions and indoor air quality (IAQ). Materials included in the review are selected considering the following aspects......: sustainability, cradle to cradle perspective, application, their impact on indoor environment and human well-being. The attempt of the paper is to cover a wide spectrum of information so to provide better understanding of waste utilization in construction industry....

  17. A Study on Public Opinion Poll and Policy on Indoor Air Pollution

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K.S.; Lee, H.S.; Kong, S.Y.; Ku, H.J. [Korea Environment Institute, Seoul (Korea)

    2001-12-01

    The purpose of this study is to review previous studies on indoor air pollution and to propose national strategies and policy measures for protecting public health from indoor air pollution based on the results of public survey research. Indoor air has the potential to be polluted by hazardous materials that might lead to serious health problems. It is well known that the indoor spaces are more polluted than outdoor ones, which can be a major health problem for those that live in urban areas who spend most of their time indoors. In Korea, studies on indoor air pollution are usually conducted under the auspices of academic research, which only focus on particular types of indoor spaces and certain concepts of indoor air quality. Thus, at present, the studies on the policies or policy measures concerning indoor air quality management are difficult to find in the country. The governmental agencies that are presently involved in the management of indoor air quality include: the Ministry of Health and Welfare, Ministry of Construction and Transportation, Ministry of Education and Human Resources Development, and Ministry of Environment. However, due to differing regulatory standards between the concerned agencies, the national management of indoor air quality has so far proven to be ineffective. Although the Ministry of Environment recently proposed a law to manage indoor air quality, it is only focuses on managing particular types of indoor spaces not regulated by other governmental bodies and is not effective in the effort towards a national managing system for indoor air pollution. According to a survey conducted by the Korea Environment Institute (KEI), the residents of the Seoul metropolitan area have been felt that environmental pollution negatively affects their health, and especially consider outdoor air pollution to be the most harmful type of pollution. Although these urban residents spend more than 20 hours a day indoors, the survey shows that they do not

  18. Differential barometric-based positioning technique for indoor elevation measurement in IoT medical applications.

    Science.gov (United States)

    Wang, Hua; Wen, Yingyou; Zhao, Dazhe

    2017-07-20

    Medical applications have begun to benefit from Internet of Things (IoT) technology through the introduction of wearable devices. Several medical applications require accurate patient location as various changes affect pressure parameters inside the body. This study aims to develop a system to measure indoor altitude for IoT medical applications. We propose a differential barometric-based positioning system to estimate the altitude between a reference sensor and a localizing sensor connected to the human body. The differential barometric altimetry model is introduced to estimate indoor elevations and eliminate environmental artifacts. In addition, a Gaussian filter processing is adopted to remove noise from the elevation measurements. The proposed system is then investigated through extensive experiments, using various evaluation criteria. The results indicate that the proposed system yielded good accuracy with reduced implementation complexity and fewer costs. The proposed system is resilient compared to other indoor localization approaches, even when numerous environmental artifacts in indoor environments are present.

  19. Analysis of indoor air pollutants checklist using environmetric technique for health risk assessment of sick building complaint in nonindustrial workplace

    Directory of Open Access Journals (Sweden)

    Syazwan AI

    2012-09-01

    workplace setting.Design: A cross-sectional study based on a participatory occupational health program conducted by the National Institute of Occupational Safety and Health (Malaysia and Universiti Putra Malaysia.Method: A modified version of the indoor environmental checklist published by the Department of Occupational Health and Safety, based on the literature and discussion with occupational health and safety professionals, was used in the evaluation process. Summated scores were given according to the cluster analysis and principal component analysis in the characterization of risk. Environmetric techniques was used to classify the risk of variables in the checklist. Identification of the possible source of item pollutants was also evaluated from a semiquantitative approach.Result: Hierarchical agglomerative cluster analysis resulted in the grouping of factorial components into three clusters (high complaint, moderate-high complaint, moderate complaint, which were further analyzed by discriminant analysis. From this, 15 major variables that influence indoor air quality were determined. Principal component analysis of each cluster revealed that the main factors influencing the high complaint group were fungal-related problems, chemical indoor dispersion, detergent, renovation, thermal comfort, and location of fresh air intake. The moderate-high complaint group showed significant high loading on ventilation, air filters, and smoking-related activities. The moderate complaint group showed high loading on dampness, odor, and thermal comfort.Conclusion: This semiquantitative assessment, which graded risk from low to high based on the intensity of the problem, shows promising and reliable results. It should be used as an important tool in the preliminary assessment of indoor air quality and as a categorizing method for further IAQ investigations and complaints procedures.Keywords: office, indoor environment quality, indoor air quality assessor, Industry Code of Practice on

  20. A Critical Review of Naphthalene Sources and Exposures Relevant to Indoor and Outdoor Air

    Directory of Open Access Journals (Sweden)

    Chunrong Jia

    2010-07-01

    Full Text Available Both the recent classification of naphthalene as a possible human carcinogen and its ubiquitous presence motivate this critical review of naphthalene’s sources and exposures. We evaluate the environmental literature on naphthalene published since 1990, drawing on nearly 150 studies that report emissions and concentrations in indoor, outdoor and personal air. While naphthalene is both a volatile organic compound and a polycyclic aromatic hydrocarbon, concentrations and exposures are poorly characterized relative to many other pollutants. Most airborne emissions result from combustion, and key sources include industry, open burning, tailpipe emissions, and cigarettes. The second largest source is off-gassing, specifically from naphthalene’s use as a deodorizer, repellent and fumigant. In the U.S., naphthalene’s use as a moth repellant has been reduced in favor of para-dichlorobenzene, but extensive use continues in mothballs, which appears responsible for some of the highest indoor exposures, along with off-label uses. Among the studies judged to be representative, average concentrations ranged from 0.18 to 1.7 μg m-3 in non-smoker’s homes, and from 0.02 to 0.31 μg m-3 outdoors in urban areas. Personal exposures have been reported in only three European studies. Indoor sources are the major contributor to (non-occupational exposure. While its central tendencies fall well below guideline levels relevant to acute health impacts, several studies have reported maximum concentrations exceeding 100 μg m-3, far above guideline levels. Using current but draft estimates of cancer risks, naphthalene is a major environmental risk driver, with typical individual risk levels in the 10-4 range, which is high and notable given that millions of individuals are exposed. Several factors influence indoor and outdoor concentrations, but the literature is inconsistent on their effects. Further investigation is needed to better characterize naphthalene

  1. Investigation of Indoor Climate in a Naturally Ventilated Office Building

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Kalyanova, Olena; Jensen, Rasmus Lund

    2008-01-01

    A measuring program in a naturally ventilated office building in Copenhagen was carried out to document the indoor climate and ventilation system performance during a year. It included a questionnaire regarding the perceived indoor environmental quality and physical measurements of thermal comfort...... to a combination of poor control of solar shading and a very high local heat load that was above the Danish recommendations for naturally ventilated office buildings. Both measured and perceived indoor air quality in the building was in general very high. The measured air flow rates was relatively high due...... to the need for cooling in the office building, while the level of infiltration was quite low indicating an airtight construction....

  2. Study on indoor radon exposure and its effect on human health

    International Nuclear Information System (INIS)

    Lu Xinwei

    2005-01-01

    Radon and its daughters relate to people health. Radon widely exists in the nature. The paper discusses the source, exposure and activity level of indoor radon, systematically analyzes the hazards and dose-response of residential radon exposure, and at last indicates the concrete method of controlling residential radon concentration. By interdicting radon pollution source and ventilation might effectively reduce indoor radon concentration and improve environmental air quality. (authors)

  3. Moisture Buffer Effect and its Impact on Indoor Environment

    DEFF Research Database (Denmark)

    Zhang, Mingjie; Qin, Menghao; Chen, Zhi

    2017-01-01

    The moisture buffer effect of building materials may have great influence on indoor hygrothermal environment. In order to characterize the moisture buffering ability of materials, the basic concept of moisture buffer value (MBV) is adopted. Firstly, a theoretical correction factor is introduced...... in this paper. The moisture uptake/release by hygroscopic materials can be calculated with the factor and the basic MBV. Furthermore, the validation of the correction factor is carried out. The impact of moisture buffering on indoor environment is assessed by using numerical simulations. The results show...

  4. A CFD study for evaluating the effects of natural ventilation on indoor comfort conditions

    Directory of Open Access Journals (Sweden)

    Miguel Mora-Pérez

    2017-03-01

    Full Text Available There is an increasing interest in improving energy efficiency in buildings due to the increased awareness about environmental impact and energy cost. Natural ventilation is an environmentally friendly technique which has become more attractive way for reducing energy use while it also provides acceptable comfort conditions. The research shows a case study building in which the natural ventilation effect due to wind-driven forces on indoor comfort conditions is evaluated. Moreover, the architectural solutions selected during the building design phase to improve the natural ventilation behaviour are successfully validated in a full-scale building. The indoor comfort conditions are evaluated through contrasted performance indicators: draught risk (DR, predicted percentage of dissatisfied people (PPD and predicted mean vote (PMV indexes. The results show that air movement due to natural ventilation allows increasing indoor air temperature maintaining the initial comfort conditions. Therefore, the mechanical air conditioning use can be postponed until the indoor air temperature is high and would, consequently, reduce the total building energy consumption. Thereby, a proper natural ventilation focus during the initial design stage could improve the building energy efficiency without compromising the indoor comfort conditions.

  5. Perceived Indoor Environment and Occupants’ Comfort in European “Modern” Office Buildings: The OFFICAIR Study

    Directory of Open Access Journals (Sweden)

    Ioannis A. Sakellaris

    2016-04-01

    Full Text Available Indoor environmental conditions (thermal, noise, light, and indoor air quality may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain. Occupants assessed indoor environmental quality (IEQ using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality, and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index, and building characteristics (office type and building’s location. Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.

  6. Perceived Indoor Environment and Occupants’ Comfort in European “Modern” Office Buildings: The OFFICAIR Study

    Science.gov (United States)

    Sakellaris, Ioannis A.; Saraga, Dikaia E.; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G.; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G.; Bluyssen, Philomena M.

    2016-01-01

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building’s location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants. PMID:27120608

  7. Research on the Implementation of Technological Measures for Controlling Indoor Environmental Quality in Green Residential Buildings

    Science.gov (United States)

    Wang, Ruozhu; Liu, Pengda; Qian, Yongmei

    2018-02-01

    This paper analyzes the design technology of controlling indoor quality in engineering practice, it is proposed that, in framework system of green residential building design, how to realize the design idea of controlling the indoor environment quality, and the design technology with feasibility, including the sunshine and lighting, indoor air quality and thermal environment, sound insulation and noise reduction measures, etc.. The results of all will provide a good theoretical supportting for the design of green residential building.

  8. Indoor climate, psychosocial work environment and symptoms in open-plan offices

    DEFF Research Database (Denmark)

    Pejtersen, J; Allermann, L; Kristensen, T S

    2006-01-01

    To study the indoor climate, the psychosocial work environment and occupants' symptoms in offices a cross-sectional questionnaire survey was made in 11 naturally and 11 mechanically ventilated office buildings. Nine of the buildings had mainly cellular offices; five of the buildings had mainly open...... irritation, skin irritation, central nervous system (CNS) symptoms and psychosocial factors. Occupants in open-plan offices are more likely to perceive thermal discomfort, poor air quality and noise and they more frequently complain about CNS and mucous membrane symptoms than occupants in multi......-person and cellular offices. The association between psychosocial factors and office size was weak. Open-plan offices may not be suited for all job types. PRACTICAL IMPLICATION: Open-plan offices may be a risk factor for adverse environmental perceptions and symptoms....

  9. Employing RADIANCE to refine indoor photocatalytic oxidation modeling

    NARCIS (Netherlands)

    Pelzers, R.S.; Yu, Q.; Mangkuto, R.A.; Brouwers, H.J.H.

    2013-01-01

    Indoor air quality (IAQ) gained great attention in the last years as one of the foremost environmental concerns and it is therefore imperative that effective methods are developed to conserve IAQ. Currently, the novel technology photocatalytic oxidation (PCO) is a potential alternative. A

  10. Results of indoor radon measurements in the republic of macedonia: - a review -

    International Nuclear Information System (INIS)

    Stojanovska, Zdenka; Boev, Blazho; Boev, Ivan

    2017-01-01

    Radon and its short lived decay products accumulated in indoor environment are the main source of public exposure to natural radiations. The health effects as well as a great number of natural and artificial factors affecting the radon accumulation in indoor environments are some of the motives for the scientific interest in radon issue. Following this global trend, many studies of indoor radon in the Balkan region, including the Republic of Macedonia have been conducted in the last decade. This paper is an overview of the published papers regarding indoor radon concentration measurements with nuclear track detectors in the Republic of Macedonia. It gives basic information about the spatial and temporal variability of indoor radon over the territory of the country, following by a description of the some factors which affect its variations. This review attempts: to organize available indoor radon results in order to show clear picture of the so far conducted surveys; to highlight the need for continuation of more extensive radon investigation in workplaces; to motivate the building professionals to create as much as possible mitigation methods for indoor radon reduction, to motivate the health professionals for epidemiological studies etc. (author)

  11. Building Information Modeling (BIM) for Indoor Environmental Performance Analysis

    DEFF Research Database (Denmark)

    The report is a part of a research assignment carried out by students in the 5ETCS course “Project Byggeri – [entitled as: Building Information Modeling (BIM) – Modeling & Analysis]”, during the 3rd semester of master degree in Civil and Architectural Engineering, Department of Engineering, Aarhus...... University. This includes seven papers describing BIM for Sustainability, concentrating specifically on individual topics regarding to Indoor Environment Performance Analysis....

  12. The measurement of 222Rn and its relationship to environmental variables: Factors controlling indoor radon: Final report for the contract period June 1, 1982 to August 31, 1986

    International Nuclear Information System (INIS)

    Harley, N.H.

    1986-01-01

    The report summarizes a project in which a new detector for measuring ''radon only'' was designed and built. The units built were then used to measure hourly data indoors and outdoors in two locations to investigate the apportionment of the indoor radon source term

  13. The measurement of 222Rn and its relationship to environmental variables: Factors controlling indoor radon: Final report for the contract period June 1, 1982 to May 31, 1985

    International Nuclear Information System (INIS)

    Harley, N.H.

    1985-01-01

    Indoor levels of radon-222 and daughter nuclei were monitored at various locations within a single family dwelling and in an apartment building. Indoor levels were correlated with soil temperature, atmospheric pressure, wind, rain and time of year. 9 refs., 23 figs., 19 tabs

  14. EPA (Environmental Protection Agency) Indoor-Air Quality Implementation Plan. A report to Congress under Title IV of the Superfund Amendments and Reauthorization Act of 1986: radon gas and indoor air-quality research. Final report

    International Nuclear Information System (INIS)

    1987-06-01

    The EPA Indoor Air Quality Implementation Plan provides information on the direction of EPA's indoor air program, including the Agency's policy on indoor air and priorities for research and information dissemination over the next two years. EPA submitted the report to Congress on July 2, 1987 as required by the Superfund Amendments and Reauthorization Act of 1986. There are five appendices to the report: Appendix A--Preliminary Indoor Air Pollution Information Assessment; Appendix B--FY 87 Indoor Air Research Program; Appendix C--EPA Radon Program; Appendix D--Indoor Air Resource History (Published with Appendix C); Appendix E--Indoor Air Reference Data Base

  15. Characterizing Aggregated Exposure to Primary Particulate Matter: Recommended Intake Fractions for Indoor and Outdoor Sources

    DEFF Research Database (Denmark)

    Fantke, Peter; Jolliet, Olivier; Apte, Joshua Schulz

    2017-01-01

    Exposure to fine particulate matter (PM_(2.5)) from indoor and outdoor sources is a leading environmental contributor to global disease burden. In response, we established under the auspices of the UNEP/SETAC Life Cycle Initiative a coupled indoor-outdoor emission-to-exposure framework to provide...

  16. Towards an integrative approach of improving indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Bluyssen, Philomena M. [TNO Built Environment and Geosciences, P.O. Box 49, 2600 AA Delft (Netherlands)

    2009-09-15

    There seems to be a discrepancy between current Indoor Air Quality standards and end-users wishes and demands. Indoor air quality can be approached from three points of view: the human, the indoor air of the space and the sources contributing to indoor air pollution. Standards currently in use mainly address the indoor air of the space. ''Other or additional'' recommendations and guidelines are required to improve indoor air quality. Even though we do not fully understand the mechanisms behind the physical, chemical, physiological and psychological processes, it is still possible to identify the different ways to be taken regulatory, politically-socially (awareness), technically (process and product) and scientifically. Besides the fact that there is an urgent need to involve medicine and neuro-psychology in research to investigate the mechanisms behind dose-response, health effects and interactions between and with the other factors and parameters of the indoor environment and the human body and mind, a holistic approach is required including the sources, the air and last but not least the human beings (occupants) themselves. This paper mainly focuses on the European situation. (author)

  17. Dynamic behavior of semivolatile organic compounds in indoor air

    Energy Technology Data Exchange (ETDEWEB)

    Loy, Michael David Van [Univ. of California, Berkeley, CA (United States)

    1998-12-09

    Exposures to a wide range of air pollutants are often dominated by those occurring in buildings because of three factors: 1) most people spend a large fraction of their time indoors, 2) many pollutants have strong indoor sources, and 3) the dilution volume in buildings is generally several orders of magnitude smaller than that of an urban airshed. Semivolatile organic compounds (SVOCS) are emitted by numerous indoor sources, including tobacco combustion, cooking, carpets, paints, resins, and glues, so indoor gasphase concentrations of these compounds are likely to be elevated relative to ambient levels. The rates of uptake and release of reversibly sorbing SVOCS by indoor materials directly affect both peak concentrations and persistence of the pollutants indoors after source elimination. Thus, accurate predictions of SVOC dynamics in indoor air require an understanding of contaminant sorption on surface materials such as carpet and wallboard. The dynamic behaviors of gas-phase nicotine and phenanthrene were investigated in a 20 ms stainless steel chamber containing carpet and painted wallboard. Each compound was studied independently, first in the empty chamber, then with each sorbent individually, and finally with both sorbents in the chamber.

  18. Indoor Air Quality and Asthma

    Directory of Open Access Journals (Sweden)

    Robert Golden

    2017-02-01

    Full Text Available Numerous contaminants in indoor air and their potential to cause or exacerbate asthma continue to be a subject of public health concern. Many agents are causally associated with or can exacerbate asthma, particularly in children. For formaldehyde, an established respiratory irritant based on numerous studies, the evidence for an association with asthma is still considered only limited or suggestive. However, there is no evidence that indicates increased sensitivity to sensory irritation to formaldehyde in people often regarded as susceptible such as asthmatics. Acrolein, but not formaldehyde, was significantly associated with asthma in a large cohort of children. This prompted an evaluation of this highly irritating chemical that had never previously been considered in the context of the indoor air/childhood asthma issue. Because acrolein is more potent than formaldehyde as a respiratory irritant and ubiquitous in indoor air, it is plausible that previous studies on potential risk factors and childhood asthma may be confounded by formaldehyde acting as an unrecognized proxy for acrolein.

  19. Indoor air quality

    DEFF Research Database (Denmark)

    Jensen, Trine Susanne; Recevska, Ieva

     The objective of the 35th specific agreement is to provide support to the EEA activities in Environment and Health (E&H) on the topic of indoor air quality. The specific objectives have been to provide an overview of indoor air related projects in EU and indoor air related policies as well...... as idenfiying "good practices" to reduce health impact of indoor air exposure and suggest areas for future improvements....

  20. Indoor air pollution and respiratory health in the elderly.

    Science.gov (United States)

    Bentayeb, Malek; Simoni, Marzia; Norback, Dan; Baldacci, Sandra; Maio, Sara; Viegi, Giovanni; Annesi-Maesano, Isabella

    2013-01-01

    Data on respiratory effects of indoor air pollution in elderly are scanty. The purpose of this review is to summarize current knowledge on adverse respiratory effects of indoor air pollution in individuals aged over 65 years, by presenting existing epidemiological evidence. Using MEDLINE database through PubMed, we identified relevant publications published between 1991 and 2011 in English on respiratory health effects of indoor air pollution in elderly (>65 years). A total of 61 studies were found and after application of the inclusion criteria: (i) epidemiologic studies published in English in peer-reviewed journals between January 1991 and December 2011, (ii) study population with age over or equal 65 years, and (iii) outcome of respiratory symptoms and disease with the exclusion of lung cancer, 33 relevant publications were selected. Most of them showed significant relationships between exposure to major indoor air pollutants and various short-term and long-term respiratory health outcomes such as wheezing, breathlessness, cough, phlegm, asthma, COPD, lung cancer and more rarely lung function decline. The most consistent relationship is found between chronic obstructive pulmonary disease (COPD) and environmental tobacco smoke (ETS). Further studies in the elderly population are needed in order to define causal relationships between exposures to indoor air pollution and underlying mechanisms in this sub-population.

  1. Standards for securing adequate indoor air quality across Europe

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Carrer, P.; de Oliveira Fernandes, E.

    2013-01-01

    Background: Inadequate IAQ causes a loss of 2 million healthy life years annually in the EU. Europeans spend typically over 85–90% of their time indoors and the main factors that affect negatively the characteristics of the air they breathe are outdoor air used to ventilate indoor spaces and indoor...... effects of IAQ into different components: exposures to indoor and outdoor air pollutants, association with different morbidities and the way ventilation based approaches could minimise their impact. Disability adjusted life years (DALYs), a common metric to allow comparability of impacts on various types...... and is determined mainly considering the metabolic CO2 production. It is only applicable if all other pollutants meet WHO guidelines for ambient and indoor air quality. If they do not meet these guidelines after applying source control and when air used for ventilation is clean health-based ventilation rate should...

  2. Indoor air quality in public utility environments-a review.

    Science.gov (United States)

    Śmiełowska, Monika; Marć, Mariusz; Zabiegała, Bożena

    2017-04-01

    Indoor air quality has been the object of interest for scientists and specialists from the fields of science such as chemistry, medicine and ventilation system design. This results from a considerable number of potential factors, which may influence the quality of the broadly understood indoor air in a negative way. Poor quality of indoor air in various types of public utility buildings may significantly affect an increase in the incidence of various types of civilisation diseases. This paper presents information about a broad spectrum of chemical compounds that were identified and determined in the indoor environment of various types of public utility rooms such as churches, museums, libraries, temples and hospitals. An analysis of literature data allowed for identification of the most important transport paths of chemical compounds that significantly influence the quality of the indoor environment and thus the comfort of living and the health of persons staying in it.

  3. Radon, smoking and human papilloma virus as risk factors for lung cancer in an environmental epidemiological study

    Directory of Open Access Journals (Sweden)

    G. P. Malinovsky

    2017-01-01

    Full Text Available The aim of the study: to analyze the risk of lung cancer caused by exposure to indoor radon using an environmental study, taking into account recent data on the possible effect of Human Papillomavirus, based on lung cancer mortality and radon exposure in the Russian regions.Materials and methods: in the analysis, linear dependencies of lung cancer against influencing factors were used. The average radon concentration for the regions of Russia was earlier reconstructed on the basis of the annual reports of the form 4-DOZ. Information on morbidity and mortality from malignant neoplasms in Russia was obtained from annual reports issued by the Р. Hertsen Moscow Oncology Research Institute. As a surrogate of the level of infection with Human Papillomavirus, the incidence of cervix cancer was used. The smoking prevalence was estimated applying data on the incidence of tongue cancer.Results: taking into account smoking and infection with Human Papillomavirus, it is possible to obtain estimates of lung cancer excess relative risk when induced by radon in dwellings consistent with the results of case-control studies.Conclusion: the analysis of regionally aggregated data on deaths from lung cancer in Russia, the average level of indoor radon concentrations and significant risk factors for lung cancer confirms the linear threshold-free concept of radiation-induced carcinogenesis.

  4. Indoor-outdoor concentrations of fine particulate matter in school building microenvironments near a mine tailing deposit

    Directory of Open Access Journals (Sweden)

    Leonardo Martínez

    2016-11-01

    Full Text Available Indoor air quality in school classrooms is a major pediatric health concern because children are highly susceptible to adverse effects from xenobiotic exposure. Fine particulate matter (PM2.5 emitted from mining waste deposits within and near cities in northern Chile is a serious environmental problem. We measured PM2.5 in school microenvironments in urban areas of Chañaral, a coastal community whose bay is contaminated with mine tailings. PM2.5 levels were measured in six indoor and outdoor school environments during the summer and winter of 2012 and 2013. Measurements were taken during school hours on two consecutive days. Indoor PM2.5 concentrations were 12.53–72.38 μg/m3 in the summer and 21.85–100.53 μg/m3 in winter, while outdoor concentrations were 11.86–181.73 μg/m3 in the summer and 21.50–93.07 μg/m3 in winter. Indoor/outdoor ratios were 0.17–2.76 in the summer and 0.64–4.49 in winter. PM2.5 levels were higher in indoor microenvironments during the winter, at times exceeding national and international recommendations. Our results demonstrate that indoor air quality Chañaral school microenvironments is closely associated with outdoor air pollution attributable to the nearby mine tailings. Policymakers should enact environmental management strategies to minimize further environmental damage and mitigate the risks that this pollution poses for pediatric health.

  5. Numerical Analysis of Indoor Sound Quality Evaluation Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Yu-Tuan Chou

    2013-01-01

    Full Text Available Indoors sound field distribution is important to Room Acoustics, but the field suffers numerous problems, for example, multipath propagation and scattering owing to sound absorption by furniture and other aspects of décor. Generally, an ideal interior space must have a sound field with clear quality. This provides both the speaker and the listener with a pleasant conversational environment. This investigation uses the Finite Element Method to assess the acoustic distribution based on the indoor space and chamber volume. In this situation, a fixed sound source at different frequencies is used to simulate the acoustic characteristics of the indoor space. This method considers the furniture and decoration sound absorbing material and thus different sound absorption coefficients and configurations. The preliminary numerical simulation provides a method that can forecast the distribution of sound in an indoor room in complex situations. Consequently, it is possible to arrange interior furnishings and appliances to optimize acoustic distribution and environmental friendliness. Additionally, the analytical results can also be used to calculate the Reverberation Time and speech intelligibility for specified indoor space.

  6. Indoor multipath mitigation

    DEFF Research Database (Denmark)

    Dragünas, Kostas; Borre, Kai

    2010-01-01

    There are many applications that require continuous positioning in combined outdoor urban and indoor environments. GNSS has been used for a long time in outdoor environments, while indoor positioning is still a challenging task. One of the major degradations that GNSS receivers experience indoors...

  7. Indoor Air Pollution and Health Risks among Rural Dwellers in ...

    African Journals Online (AJOL)

    `123456789jkl''''#

    Ethiopian Journal of Environmental Studies and Management Vol.3 No.2 2010 ... occurrence of air pollution related health problems among the rural dwellers, one ... Key words: Indoor environment, air quality, rural health, fuel-wood.

  8. Indoor air pollution

    International Nuclear Information System (INIS)

    Spengler, J.D.

    1985-01-01

    Although official efforts to control air pollution have traditionally focused on outdoor air, it is now apparent that elevated contaminant concentrations are common inside some private and public buildings. Concerns about potential public health problems due to indoor air pollution are based on evidence that urban residents typically spend more than 90 percent of their time indoors, concentrations of some contaminants are higher indoors than outdoors, and for some pollutants personal exposures are not characterized adequately by outdoor measurements. Among the more important indoor contaminants associated with health or irritation effects are passive tobacco smoke, radon decay products, carbon monoxide, nitrogen dioxide, formaldehyde, asbestos fibers, microorganisms and aeroallergens. Efforts to assess health risks associated with indoor air pollution are limited by insufficient information about the number of people exposed, the pattern and severity of exposures, and the health consequences of exposures. An overall strategy should be developed to investigate indoor exposures, health effects, control options, and public policy alternatives

  9. Scopulariopsis and scopulariopsis-like species from indoor environments

    Directory of Open Access Journals (Sweden)

    J.H.C. Woudenberg

    2017-09-01

    Full Text Available Scopulariopsis-like species are often reported from the indoor environment, as well as from clinical samples. The lack of type isolates and thorough phylogenetic studies in the Microascaceae hampered the correct identification of these isolates. Based on recent phylogenetic studies, which resulted in multiple name changes, the aim is to molecularly identify the Scopulariopsis and scopulariopsis-like species which occur in the indoor environment and give an overview of the current species in these genera and their habitats. Strains from the CBS culture collection were supplemented with almost 80 indoor strains of which the internal transcribed spacer 1 and 2 and intervening 5.8S nrDNA (ITS, beta-tubulin (tub2 and translation elongation factor 1-alpha (tef1 gene regions were sequenced for phylogenetic inference. The multi-gene phylogenies recognise 33 Microascus species and 12 Scopulariopsis species and showed that the recently established genus Fuscoannellis, typified by Scopulariopsis carbonaria, should be synonymized with the genus Yunnania. Seven new Microascus species, four new Scopulariopsis species, and one new Yunnania species, are described, and a new name in Microascus and two new name combinations (one in Microascus, and one in Yunnania are proposed. In the indoor environment 14 Microascus species and three Scopulariopsis species were found. Scopulariopsis brevicaulis (22 indoor isolates and Microascus melanosporus (19 indoor isolates are the most common indoor species, in number of isolates, followed by M. paisii (8 indoor isolates and S. candida (7 indoor isolates. A genus phylogeny based on the ITS, tef1 and the large subunit 28S nrDNA (LSU of the type or representative isolates of all here recognised species is provided depicting all species habitats. No correlation between phylogenetic relationship and habitat preference could be observed. Ten species which are found indoor are also found in relation with human-derived samples. A

  10. A View Indoors, Indoor Environment Division's e-Article Series

    Science.gov (United States)

    The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.

  11. Indoor radon and decay products: Concentrations, causes, and control strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nero, A.V.; Gadgil, A.J.; Nazaroff, W.W.; Revzan, K.L.

    1990-11-01

    This report is another in the on going technical report series that addresses various aspects of the DOE Radon Research Program. It provides an overview of what is known about the behavior of radon and its decay products in the indoor environment and examines the manner in which several important classes of factors -- structural, geological, and meteorological -- affect indoor radon concentrations. Information on US indoor radon concentrations, currently available monitoring methods and novel radon control strategies are also explored. 238 refs., 22 figs., 9 tabs.

  12. Relationships in indoor/outdoor air pollution

    International Nuclear Information System (INIS)

    Roed, J.

    1985-01-01

    Beryllium-7 and sulphurhexaflourid has been used as tracers in measurements designed to enable an estimate of the ratio of the outdoor to indoor time-integrated concentration for aerosols and non-reactive gasses of outdoor origin with a special reference to the reduction in inhalation dose that can be achieved by staying indoors during a pollution episode, especially a reactor accident. The effect of operating a vacuum cleaner during the pollution episode and airing shortly after is also investigated. Earlier relevant literature is reviewed and shows goos agreement with the results in this study. Protection factor from 1-12 has been found. (author)

  13. A pilot study using scripted ventilation conditions to identify key factors affecting indoor pollutant concentration and air exchange rate in a residence.

    Science.gov (United States)

    Johnson, Ted; Myers, Jeffrey; Kelly, Thomas; Wisbith, Anthony; Ollison, Will

    2004-01-01

    A pilot study was conducted using an occupied, single-family test house in Columbus, OH, to determine whether a script-based protocol could be used to obtain data useful in identifying the key factors affecting air-exchange rate (AER) and the relationship between indoor and outdoor concentrations of selected traffic-related air pollutants. The test script called for hourly changes to elements of the test house considered likely to influence air flow and AER, including the position (open or closed) of each window and door and the operation (on/off) of the furnace, air conditioner, and ceiling fans. The script was implemented over a 3-day period (January 30-February 1, 2002) during which technicians collected hourly-average data for AER, indoor, and outdoor air concentrations for six pollutants (benzene, formaldehyde (HCHO), polycyclic aromatic hydrocarbons (PAH), carbon monoxide (CO), nitric oxide (NO), and nitrogen oxides (NO(x))), and selected meteorological variables. Consistent with expectations, AER tended to increase with the number of open exterior windows and doors. The 39 AER values measured during the study when all exterior doors and windows were closed varied from 0.36 to 2.29 h(-1) with a geometric mean (GM) of 0.77 h(-1) and a geometric standard deviation (GSD) of 1.435. The 27 AER values measured when at least one exterior door or window was opened varied from 0.50 to 15.8 h(-1) with a GM of 1.98 h(-1) and a GSD of 1.902. AER was also affected by temperature and wind speed, most noticeably when exterior windows and doors were closed. Results of a series of stepwise linear regression analyses suggest that (1) outdoor pollutant concentration and (2) indoor pollutant concentration during the preceding hour were the "variables of choice" for predicting indoor pollutant concentration in the test house under the conditions of this study. Depending on the pollutant and ventilation conditions, one or more of the following variables produced a small, but

  14. Plants Clean Air and Water for Indoor Environments

    Science.gov (United States)

    2007-01-01

    Wolverton Environmental Services Inc., founded by longtime government environmental scientist B.C. "Bill" Wolverton, is an environmental consulting firm that gives customers access to the results of his decades of cutting-edge bioremediation research. Findings about how to use plants to improve indoor air quality have been published in dozens of NASA technical papers and in the book, "How to Grow Fresh Air: 50 Houseplants That Purify Your Home or Office." The book has now been translated into 12 languages and has been on the shelves of bookstores for nearly 10 years. A companion book, "Growing Clean Water: Nature's Solution to Water Pollution," explains how plants can clean waste water. Other discoveries include that the more air that is allowed to circulate through the roots of the plants, the more effective they are at cleaning polluted air; and that plants play a psychological role in welfare in that people recover from illness faster in the presence of plants. Wolverton Environmental is also working in partnership with Syracuse University, to engineer systems consisting of modular wicking filters tied into duct work and water supplies, essentially tying plant-based filters into heating, ventilation, and air conditioning (HVAC) systems. Also, the company has recently begun to assess the ability of the EcoPlanter to remove formaldehyde from interior environments. Wolverton Environmental is also in talks with designers of the new Stennis Visitor's Center, who are interested in using its designs for indoor air-quality filters

  15. Indoor particle levels in small- and medium-sized commercial buildings in California.

    Science.gov (United States)

    Wu, Xiangmei May; Apte, Michael G; Bennett, Deborah H

    2012-11-20

    This study monitored indoor and outdoor particle concentrations in 37 small and medium commercial buildings (SMCBs) in California with three buildings sampled on two occasions, resulting in 40 sampling days. Sampled buildings included offices, retail establishments, restaurants, dental offices, and hair salons, among others. Continuous measurements were made for both ultrafine and fine particulate matter as well as black carbon inside and outside of the building. Integrated PM(2.5), PM(2.5-10), and PM(10) samples were also collected inside and outside the building. The majority of the buildings had indoor/outdoor (I/O) particle concentration ratios less than 1.0, indicating that contributions from indoor sources are less than removal of outdoor particles. However, some of the buildings had I/O ratios greater than 1, indicating significant indoor particle sources. This was particularly true of restaurants, hair salons, and dental offices. The infiltration factor was estimated from a regression analysis of indoor and outdoor concentrations for each particle size fraction, finding lower values for ultrafine and coarse particles than for submicrometer particles, as expected. The I/O ratio of black carbon was used as a relative measure of the infiltration factor of particles among buildings, with a geometric mean of 0.62. The contribution of indoor sources to indoor particle levels was estimated for each building.

  16. Indoor Decontamination Textiles by Photocatalytic Oxidation: A Review

    Directory of Open Access Journals (Sweden)

    Hafeezullah Memon

    2015-01-01

    Full Text Available A large number of researches have been made to make the textile intelligent and smarter; this is achieved by imparting functionality to the textile materials. The indoor environment possesses a variety of pollutants which do not come from the outer environment, but they come from the inner environment itself. Today, the smarter fabrics that may clean the indoor air have been studied by various researchers. The smarter fabrics contain the nanocoating of semiconductor oxides, mostly TiO2; thus the synthesis and application of these nanoparticles on the textile material have been reviewed in this paper. Moreover, there are lots of environmental and health issues regarding nanoparticles that have also been discussed in brief.

  17. Environmental Radiation Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Environmental Radiation Data (ERD) is an electronic and print journal compiled and distributed quarterly by the Office of Radiation and Indoor Air's National Air and...

  18. Coping with Indoor Air Pollution

    Science.gov (United States)

    ... Pollution > Coping with Indoor Air Pollution Font: Outdoor Pollution Indoor Air Pollution Asthma Triggers For Kids and Teachers Coping with Indoor Air Pollution Indoor air pollution is irritating to everyone: But people who ...

  19. Health effects from indoor air pollution: case studies.

    Science.gov (United States)

    White, L E; Clarkson, J R; Chang, S N

    1987-01-01

    In recent years there has been a growing awareness of the health effects associated with the presence of contaminants in indoor air. Numerous agents can accumulate in public buildings, homes and automobiles as a result of ongoing activities that normally occur in these closed spaces. Ventilation is a major factor in the control of indoor air pollutants since proper movement of air can prevent or minimize the build up of compounds in buildings. The recent emphasis on energy conservation has lead to measures which economize on energy for heating and air conditioning, but which also trap pollutants within a building. Three cases of indoor air pollution were investigated. A typical investigation of indoor air pollutant problems includes the following: interviews with building occupants; history of the building with regard to maintenance, pesticide treatment, etc.; a survey of the building and ventilation; and when warranted, sampling and analysis of air. Each case presented is unique in that atypical situations caused agents to accumulate in a building or section of a building. The indoor air problems in these cases were solved by identifying and removing the source of the offending agent and/or improving the ventilation in the building.

  20. Indoor Air Quality in Schools.

    Science.gov (United States)

    Torres, Vincent M.

    Asserting that the air quality inside schools is often worse than outdoor pollution, leading to various health complaints and loss of productivity, this paper details factors contributing to schools' indoor air quality. These include the design, operation, and maintenance of heating, ventilating, and air conditioning (HVAC) systems; building…

  1. Indoor Tanning

    Science.gov (United States)

    ... proof that indoor tanning is safer than tanning outdoors. Indoor tanning systems give concentrated UV exposure regardless ... For example, it’s essential for promoting good bone health. While UV ... a tan to get that benefit. According to the Surgeon General, fair and light- ...

  2. Assessing indoor air quality options: Final environmental impact statement on new energy-efficient home programs: Volume 2

    International Nuclear Information System (INIS)

    1988-03-01

    This report discusses the impact of energy conservation measures on indoor air quality in various size residential buildings. This volume includes appendices on ventilation rates, indoor pollutant levels, health effects, human risk assessment, radon, fiberglass hazards, tobacco smoke, mitigation

  3. The Bonneville Power Administration new energy-efficient homes programs: Final environmental impact statement: Volume 1, Assessing indoor air quality options

    International Nuclear Information System (INIS)

    1988-03-01

    BPA has underway marketing and incentive programs to encourage the construction of new energy-efficient homes that comply with Model Conservation Standards (MCS) developed by the Northwest Power Planning Council. These homes are designed to have lower infiltration rates than current building practices provide, which is likely to contribute to increased levels of indoor air pollutants, and may adversely affect the health of occupants. BPA's current and past new homes programs maintained ventilation rates comparable to those found in current practice homes by requiring balanced mechanical ventilation. BPA now proposes to give builders and consumers more flexibility by increasing the options for protecting indoor air quality in its new homes programs. This proposal is the impetus for this Environmental Impact Statement (EIS), which was prepared for BPA by Pacific Northwest Laboratory. BPS is preparing this EIS to assess whether other techniques maintain indoor air quality comparable to that found in homes built using current practices. Although many pollutants are potentially of great concern, our analysis concentrates on radon and formaldehyde. It is based on measured concentrations of these pollutants and measured ventilation rates in current practice. Ventilation was measured using fan pressurization tests, which measure only air leakage, and perfluorocarbon tracer gas (PFT) tests, which account for ventilation from mechanical devices and occupant behavior in addition to air leakage. These tests yielded two different estimates. We used these data to estimate pollutant concentrations and lifetime cancer rates under three alternative actions. Under all of the alternatives, radon had a much greater effect than formaldehyde. 102 refs

  4. Ambient radiation dose to the population of the city of Sao Paulo-Brazil: indoor gamma distribution

    International Nuclear Information System (INIS)

    Otsubo, Sergio M.; Yoshimura, Elizabeth M.

    2001-01-01

    The objective of this work is to present results of indoor ambient dose equivalent rate (H * (10)) in the city of Sao Paulo. Studies show that people of industrialized cities spend indoor approximately 80% of their time, and that there are great variations of the rate of H * (10) all over the world. Values of environmental radiation are important base to epidemiological studies, or analyses of consequences and effects of radioactive or nuclear accidents and also to assist research on biological effects of low doses, a very controversial subject in the literature. There are no reports in the literature about environmental radiation in the city of Sao Paulo, showing the important of this study. Environmental radiation exists everywhere in the planet, so the human beings are exposed to it at any time or place, being indoor or outdoor. Three types of commercial indoor ambient with large flow of the population were analyzed: bank offices, shops in the neighborhood of the banks, and shopping centers. A gamma ray portable spectrometer was used, composed by a crystal of NaI (Tl). The mean value of the H * (10) rate obtained was 173,8(17) nSv/h. The results analyzed by commerce type and by the health divisions of the city are also presented. (author)

  5. Testing a social cognitive theory-based model of indoor tanning: implications for skin cancer prevention messages.

    Science.gov (United States)

    Noar, Seth M; Myrick, Jessica Gall; Zeitany, Alexandra; Kelley, Dannielle; Morales-Pico, Brenda; Thomas, Nancy E

    2015-01-01

    The lack of a theory-based understanding of indoor tanning is a major impediment to the development of effective messages to prevent or reduce this behavior. This study applied the Comprehensive Indoor Tanning Expectations (CITE) scale in an analysis of indoor tanning behavior among sorority women (total N = 775). Confirmatory factor analyses indicated that CITE positive and negative expectations were robust, multidimensional factors and that a hierarchical structure fit the data well. Social cognitive theory-based structural equation models demonstrated that appearance-oriented variables were significantly associated with outcome expectations. Outcome expectations were, in turn, significantly associated with temptations to tan, intention to tan indoors, and indoor tanning behavior. The implications of these findings for the development of messages to prevent and reduce indoor tanning behavior are discussed in two domains: (a) messages that attempt to change broader societal perceptions about tan skin, and (b) messages that focus more narrowly on indoor tanning-challenging positive expectations, enhancing negative expectations, and encouraging substitution of sunless tanning products.

  6. Influences of Green Outdoors versus Indoors Environmental Settings on Psychological and Social Outcomes of Controlled Exercise

    Science.gov (United States)

    Rogerson, Mike; Gladwell, Valerie F.; Gallagher, Daniel J.; Barton, Jo L.

    2016-01-01

    This study addressed a methodological gap by comparing psychological and social outcomes of exercise in green outdoors versus built indoors settings, whilst rigorously controlling exercise mode and intensity. The hypotheses were that greater improvements or more desirable values for directed attention, mood, perceived exertion, social interaction time, intention for future exercise behaviour and enjoyment would be associated with outdoors compared to indoors exercise. Following a baseline session, paired participants completed two conditions of 15 min of cycling on an ergometer placed outside in a natural environment and inside in a laboratory setting in a randomized, counter-balanced order. At pre- and post-exercise, directed attention was measured with the digit span backwards task, and mood was assessed with the Profile of Mood States. During the exercise session, visual and verbal interactions were recorded by means of experimenter observations. After each exercise session, participants provided self-reports of their enjoyment of the exercise, perceived exertion and intention for future exercise in the same environment. Social interaction time was significantly greater during outdoors exercise versus indoors; on average, participants engaged in three minutes more social interaction during exercise outdoors compared to indoors. Social interaction time significantly predicted intention for future exercise in the outdoors condition, but did not in the indoor condition. There was a significant time by condition interaction for directed attention. Scores worsened in the indoors condition, but improved in the outdoors condition. There was no statistically-significant time by condition interaction for mood and no significant difference between conditions for either perceived exertion or intention. Taken together, these findings show that exercise in a natural environment may promote directed attention and social interactions, which may positively influence future

  7. Exposure to indoor tanning without burning and melanoma risk by sunburn history.

    Science.gov (United States)

    Vogel, Rachel Isaksson; Ahmed, Rehana L; Nelson, Heather H; Berwick, Marianne; Weinstock, Martin A; Lazovich, DeAnn

    2014-06-01

    Indoor tanning is carcinogenic to humans. Individuals report that they tan indoors before planning to be in the sun to prevent sunburns, but whether skin cancer is subsequently reduced is unknown. Using a population-based case-control study, we calculated the association between melanoma and indoor tanning after excluding exposed participants reporting indoor tanning-related burns, stratified by their number of lifetime sunburns (0, 1-2, 3-5, >5). Confounding was addressed using propensity score analysis methods. All statistical tests were two-sided. We observed increased risk of melanoma across all sunburn categories for participants who had tanned indoors without burning compared with those who never tanned indoors, including those who reported zero lifetime sunburns (odds ratio = 3.87; 95% confidence interval = 1.68 to 8.91; P = .002). These data provide evidence that indoor tanning is a risk factor for melanoma even among persons who reported never experiencing burns from indoor tanning or outdoor sun exposure. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  8. Radon and aldehyde concentrations in the indoor environment. Final report

    International Nuclear Information System (INIS)

    Moschandreas, D.J.; Rector, H.E.

    1981-04-01

    Findings regarding indoor air contaminants in the energy-efficient residence (EER) in Mt. Airy, Maryland are reported. The objectives of the study were to collect and analyze relevant air quality samples (specifically radon and aldehydes), characterize the indoor air quality with respect to radon and aldehydes, and develop relationships between air infiltration rates and contaminant levels. One-fifth of the measured formaldehyde concentrations were in the range that may cause health concerns. Although indoor temperature and relative humidity affect indoor HCHO concentration, the elevated formaldehyde concentrations were measured under very low air infiltration rates. The data show that ventilation of the indoor air space is somewhat effective in reducing high HCHO concentrations. The operation of the heat exchanger led to an increase of the air infiltration rate which in turn resulted in substantial reduction of formaldehyde concentrations. A considerable number of the collected samples of indoor air displayed radon concentrations at levels higher than 1.0 to 4.0 nCim -3 (assuming an equilibrium factor of 0.5, these radon levels would correspond to working levels above the health guidelines suggested by the US EPA for homes in Florida built on land reclaimed from phosphate mining). As in the case of indoor formaldehyde concentrations, elevated indoor concentrations are substantially reduced when the infiltration rate is increased. The data base shows that the use of the air to air heat exchanger leads to reduction of indoor radon concentration by increasing the residential ventilation rate

  9. Enabling Indoor Location-Based Services

    DEFF Research Database (Denmark)

    Radaelli, Laura

    Indoor spaces have always attracted interest from different scientific disciplines. Relatively recent interest in indoor settings by computer scientists is driven in part by the increasing use of smartphones, which serve as a platform for service delivery and can generate extensive volumes...... of trajectory data that can be used to study how people actually use indoor spaces. In this dissertation, we contribute partial solutions that address challenges in indoor positioning and indoor trajectory management and analysis. The key enabler of indoor location-based services and indoor movement analysis...... is a well-functioning positioning system that can be easily deployed in most public places. Different technologies are able to provide indoor positioning with different accuracy and coverage, but it is difficult to find a technology that by itself can provide good positioning in the many different layouts...

  10. Introduction to the risk assessment workshop on indoor air quality

    International Nuclear Information System (INIS)

    Oezkaynak, H.; Spengler, J.D.

    1990-01-01

    Due to the emerging importance of the indoor air-quality problem and associated health risk concerns, on December 6-8, 1988 a three-day workshop on indoor air-quality risk assessment was jointly organized by Harvard University, Energy and Environmental Policy Center, and the Harvard School of Public Health. This introduction briefly summarizes the objectives of the workshop and its agenda. The workshop consisted of presentations and discussions by researchers from academic, government, and private institutions. Among the participants were those who have been involved in the design of major field studies of human exposure, physicians and toxicologists involved in clinical studies, human exposure modelers, and epidemiologists and health risk assessors. The overall objective of the workshop was to examine the critical elements needed to perform risk assessments on major indoor air pollutants. Eight pollutants were chosen for discussion: environmental tobacco smoke, formaldehyde, radon, volatile organic compounds, biologicals, man-made mineral fibers, nitrogen dioxide, and semivolatile organic compounds. Twenty-two papers were presented in the workshop. Eight of these papers are published in this issue of Risk Analysis. Nine of the remaining fourteen will shortly be published in the 'Exposure Assessment Section' issue of the Journal of Toxicology and Industrial Health

  11. Do indoor chemicals promote development of airway allergy?

    DEFF Research Database (Denmark)

    Nielsen, G D; Larsen, S T; Olsen, O

    2007-01-01

    in animal studies and allergy-promoting effects in humans. Quaternary ammonium compounds may possess adjuvant effects in animal studies and promoted sensitization in humans in occupational settings. The use of cleaning agents, anionic and non-ionic surfactants are not considered to possess an important...... products, the important question may be would it be profitable to look for lifestyle factors and non-chemical indoor exposures in order to abate airway allergy? PRACTICAL IMPLICATIONS: Indoor chemicals (pollutants) have been accused to promote development of airway allergy by adjuvant effects......Allergic asthma has increased worldwide in the industrialized countries. This review evaluates whether the major groups of indoor chemical exposures possess allergy-promoting (adjuvant) effects; formaldehyde was excluded, because of the size of the literature. Volatile organic compounds (VOCs...

  12. Indoor radon measurements and methodologies in Latin American countries

    International Nuclear Information System (INIS)

    Canoba, A.; Lopez, F.O.; Arnaud, M.I.; Oliveira, A.A.; Neman, R.S.; Hadler, J.C.; Iunes, P.J.; Paulo, S.R.; Osorio, A.M.; Aparecido, R.; Rodriguez, C.; Moreno, V.; Vasquez, R.; Espinosa, G.; Golzarri, J.I.; Martinez, T.; Navarrete, M.; Cabrera, I.; Segovia, N.; Pena, P.; Tamez, E.; Pereyra, P.; Lopez-Herrera, M.E.; Sajo-Bohus, L.

    2001-01-01

    According to the current international guidelines concerning environmental problems, it is necessary to evaluate and to know the indoor radon levels, specially since most of the natural radiation dose to man comes from radon gas and its progeny. Several countries have established National Institutions and National Programs for the study of radon and its connection with lung cancer risk and public health. The aim of this work is to present the indoor radon measurements and the detection methods used for different regions of Latin America (LA) in countries such as Argentina, Brazil, Ecuador, Mexico, Peru and Venezuela. This study shows that the passive radon devices based on alpha particle nuclear track methodology (NTM) is one of the more generalized methods in LA for long term indoor radon measurements, CR-39, LR-115 and Makrofol being the more commonly used detector materials. The participating institutions and the radon level measurements in the different countries are presented in this contribution

  13. Polycyclic aromatic hydrocarbons and their derivatives in indoor and outdoor air in an eight-home study

    Science.gov (United States)

    Chuang, Jane C.; Mack, Gregory A.; Kuhlman, Michael R.; Wilson, Nancy K.

    A pilot field study was performed in Columbus, OH, during the winter of 1986/1987. The objectives were to determine the feasibility of the use of a newly developed quiet sampler in indoor air sampling for particles and semivolatile organic compounds (SVOC) and to measure the concentrations of polycyclic aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in air in selected residences. Eight homes were chosen for sampling on the basis of these characteristics: electric/gas heating system, electric/gas cooking appliances, and the absence/presence of environmental tobacco smoke (ETS). The indoor sampler was equipped with a quartz-fiber filter to collect particles followed by XAD-4 resin to trap SVOC. A PS-1 sampler with a similar sampling module was used outdoors. The indoor air was sampled in the kitchen and living room areas over two consecutive 8-h periods. The outdoor air was sampled concurrently with the indoor samples over a 16-h period. Fifteen PAH, five nitro-PAH, five oxygenated PAH, and three nitrogen heterocyclic compounds were determined in these samples. The most abundant PAH found indoors was naphthalene. The indoor concentrations of PAH derivatives were lower than those of their parent compounds. Average concentrations of all but three target compounds (naphthalene dicarboxylic acid anhydride, pyrene dicarboxylic acid anhydride, and 2-nitrofluoranthene) were higher indoors than outdoors. Environmental tobacco smoke was the most significant influence on indoor pollutant levels. Homes with gas heating systems had higher indoor pollutant levels than homes with electric heating systems. However, the true effects of heating and cooking systems were not characterized as accurately as the effects of ETS because of the small sample sizes and the lack of statistical significance for most pollutant differences in the absence of ETS. The concentrations of PAH marker compounds (phenanthrene, fluoranthene, and pyrene) correlated well with the concentrations

  14. Air exchanges and indoor carbon dioxide concentration in Australian pig buildings: Effect of housing and management factors

    DEFF Research Database (Denmark)

    Banhazi, T. M.; Stott, P.; Rutley, D.

    2011-01-01

    There has been a growing interest in improving air quality within livestock buildings. However, the influence of housing and management factors on air exchange rates and indoor gas concentrations is not well understood. The aim of this study was to determine the effects of housing and management...... production, although these buildings may not always provide an optimal environment for pig production. (C) 2011 IAgrE. Published by Elsevier Ltd. All rights reserved....

  15. Analysing the causes of chronic cough: relation to diesel exhaust, ozone, nitrogen oxides, sulphur oxides and other environmental factors

    Directory of Open Access Journals (Sweden)

    Wagner Ulrich

    2006-05-01

    Full Text Available Abstract Air pollution remains a leading cause of many respiratory diseases including chronic cough. Although episodes of incidental, dramatic air pollution are relatively rare, current levels of exposure of pollutants in industrialized and developing countries such as total articles, diesel exhaust particles and common cigarette smoke may be responsible for the development of chronic cough both in children and adults. The present study analyses the effects of common environmental factors as potential causes of chronic cough. Different PubMed-based researches were performed that related the term cough to various environmental factors. There is some evidence that chronic inhalation of diesel can lead to the development of cough. For long-term exposure to nitrogen dioxide (NO2, children were found to exhibit increased incidences of chronic cough and decreased lung function parameters. Although a number of studies did not show that outdoor pollution directly causes the development of asthma, they have demonstrated that high levels pollutants and their interaction with sunlight produce ozone (O3 and that repeated exposure to it can lead to chronic cough. In summary, next to the well-known air pollutants which also include particulate matter and sulphur dioxide, a number of other indoor and outdoor pollutants have been demonstrated to cause chronic cough and therefore, environmental factors have to be taken into account as potential initiators of both adult and pediatric chronic cough.

  16. Do obese adults have a higher risk of asthma attack when exposed to indoor mold? A study based on the 2005 Behavioral Risk Factor Surveillance System.

    Science.gov (United States)

    Wen, Xiao-Jun; Balluz, Lina; Mokdad, Ali

    2009-01-01

    Some studies show an association between asthma and obesity, but it is unknown whether exposure to mold will increase the risk of asthma attacks among obese people. This study examined whether obese adults have a higher risk of asthma attacks than non-obese adults when exposed to indoor mold. We used data from the 2005 Behavioral Risk Factor Surveillance System to conduct a cross-sectional analysis among 9,668 respondents who reported exposure to indoor mold. With exposure to indoor mold, weighted prevalence of asthma attacks among obese respondents was 11.4% (95% confidence interval [CI] 6.0, 20.6], which was 2.3 times as high as among the exposed non-obese respondents (5.0%, 95% CI 2.8, 8.8). This ratio was almost the same as the ratio of 2.0:1 between the obese respondents (5.7%, 95% CI 4.6, 7.2) and the non-obese respondents (2.8%, 95% CI 2.3, 3.9) when neither group had exposure to mold. The odds ratio of asthma attack among obese people was 3.10 (95% CI 1.10, 8.67) for those with exposure to mold and 2.21 (95% CI 1.54, 3.17) for those without exposure to mold after adjusting for age, sex, race/ethnicity, and smoking status. Our study suggests that obese adults who have been exposed to indoor mold may not necessarily have a higher risk of asthma attack than obese adults who have not been exposed, even though obesity and exposure to indoor mold are both major risk factors for asthma attack. Medical professionals should not only incorporate weight-control or weight-reduction measures as the components of asthma treatment plans, but also advise asthma patients to avoid exposure to indoor mold.

  17. ASSOCIATIONS BETWEEN SEASONAL SLEEP CHANGE AND INDOOR TANNING1,2

    Science.gov (United States)

    CULNAN, ELIZABETH; KLOSS, JACQUELINE D.; DARLOW, SUSAN; HECKMAN, CAROLYN J.

    2015-01-01

    Summary Identification of risk factors for indoor tanning may ultimately aid the development of better indoor tanning prevention strategies, which is pertinent given the association between indoor tanning and skin cancer. This study aimed to examine the relationship between seasonal sleep change and indoor tanning. Women tanners (N= 139) completed self-report measures including items relating to seasonal sleep changes, seasonal affective disorder (SAD), reasons for tanning, tanning during the winter months, and the Tanning Pathology Scale (TAPS), which measures problematic tanning motives and symptoms of tanning dependence. It was hypothesized that seasonal sleep change and SAD would be associated with greater indoor tanning during the winter, more tanning to improve mood and to relax, and higher scores on the TAPS. Findings indicated that more seasonal sleep change was associated with tanning to improve mood and higher scores on the TAPS. Similarly, the presence of SAD was related to tanning to improve mood, tanning to relax, and more problematic tanning. PMID:25730744

  18. Quick Estimation Model for the Concentration of Indoor Airborne Culturable Bacteria: An Application of Machine Learning

    Directory of Open Access Journals (Sweden)

    Zhijian Liu

    2017-07-01

    Full Text Available Indoor airborne culturable bacteria are sometimes harmful to human health. Therefore, a quick estimation of their concentration is particularly necessary. However, measuring the indoor microorganism concentration (e.g., bacteria usually requires a large amount of time, economic cost, and manpower. In this paper, we aim to provide a quick solution: using knowledge-based machine learning to provide quick estimation of the concentration of indoor airborne culturable bacteria only with the inputs of several measurable indoor environmental indicators, including: indoor particulate matter (PM2.5 and PM10, temperature, relative humidity, and CO2 concentration. Our results show that a general regression neural network (GRNN model can sufficiently provide a quick and decent estimation based on the model training and testing using an experimental database with 249 data groups.

  19. Cross-Sectional Associations between Home Environmental Factors and Domain-Specific Sedentary Behaviors in Adults: The Moderating Role of Socio-Demographic Variables and BMI

    Science.gov (United States)

    Busschaert, Cedric; Cardon, Greet; Chastin, Sebastien F. M.; Van Cauwenberg, Jelle; De Cocker, Katrien

    2017-01-01

    Despite the negative health effects of too much sitting, the majority of adults are too sedentary. To develop effective interventions, insight is needed into home environmental correlates of adults’ sedentary behaviors, and into the susceptibility of population subgroups to these home environmental cues. In total, 559 Flemish adults reported socio-demographics, weight and height, home environmental factors and domain-specific sedentary behaviors. Generalized linear modeling was conducted to examine main associations between home environmental factors and domain-specific sedentary behaviors, and to test the moderating role of socio-demographics and BMI on these associations. In case of significant interactions, stratified analyses were performed. Results showed that, among those who did use a computer/laptop during the last week, a one-unit increase in the number of computers or laptops was associated with 17% (OR = 1.17; 95% CI = 1.02, 1.34) and 24% (OR = 1.24; 95% CI = 1.08, 1.43) more minutes computer time per day, respectively. The proximity of the remote controller (p moderated by BMI, with significant positive associations limited to those not overweight. To conclude, home environmental factors were associated with domain-specific sedentary behaviors, especially in healthy weight adults. If confirmed by longitudinal studies, public health professionals should encourage adults to limit the number of indoor entertainment devices and motorized vehicles. PMID:29088089

  20. Indoor Climate Quality Assessment -

    DEFF Research Database (Denmark)

    Ansaldi, Roberta; Asadi, Ehsan; Costa, José Joaquim

    This Guidebook gives building professionals useful support in the practical measurements and monitoring of the indoor climate in buildings. It is evident that energy consumption in a building is directly influenced by required and maintained indoor comfort level. Wireless technologies for measure...... for measurement and monitoring have allowed a significantly increased number of possible applications, especially in existing buildings. The Guidebook illustrates several cases with the instrumentation of the monitoring and assessment of indoor climate.......This Guidebook gives building professionals useful support in the practical measurements and monitoring of the indoor climate in buildings. It is evident that energy consumption in a building is directly influenced by required and maintained indoor comfort level. Wireless technologies...

  1. Towards Mobile Information Systems for Indoor Space

    Directory of Open Access Journals (Sweden)

    Xiaoxiang Zhang

    2016-01-01

    Full Text Available With the rapid development of Internet of things (IOT and indoor positioning technologies such as Wi-Fi and RFID, indoor mobile information systems have become a new research hotspot. Based on the unique features of indoor space and urgent needs on indoor mobile applications, in this paper we analyze some key issues in indoor mobile information systems, including positioning technologies in indoor environments, representation models for indoor spaces, query processing techniques for indoor moving objects, and index structures for indoor mobile applications. Then, we present an indoor mobile information management system named IndoorDB. Finally, we give some future research topics about indoor mobile information systems.

  2. Occurrence, sources and human exposure assessment of SCCPs in indoor dust of northeast China.

    Science.gov (United States)

    Liu, Li-Hua; Ma, Wan-Li; Liu, Li-Yan; Huo, Chun-Yan; Li, Wen-Long; Gao, Chong-Jing; Li, Hai-Ling; Li, Yi-Fan; Chan, Hing Man

    2017-06-01

    Short-chain chlorinated paraffins (SCCPs) are widely used chemicals in household products and might cause adverse human health effects. However, limited information is available on the occurrence of SCCPs in indoor environments and their exposure risks on humans. In this study the concentrations, profiles and human exposure of SCCPs in indoor dust from five different indoor environments, including commercial stores, residential apartments, dormitories, offices and laboratories were characterized. The SCCPs levels ranged from 10.1 to 173.0 μg/g, with the median and mean concentration of 47.2 and 53.6 μg/g, respectively. No significant difference was found on concentrations among the five microenvironments. The most abundant compounds in indoor dust samples were homologues of C 13 group, Cl 7 group and N 20 (N is the total number of C and Cl) group. In the five microenvironments, commercial stores were more frequently exposed to shorter carbon chained and higher chlorinated homologues. Three potential sources for SCCPs were identified by the multiple linear regression of factor score model and correspondence analysis. The major sources of SCCPs in indoor dust were technical mixtures of CP-42 (42% chlorine, w/w) and CP-52 b (52% chlorine, w/w). The total daily exposure doses and hazard quotients (HQ) were calculated by the human exposure models, and they were all below the reference doses and threshold values, respectively. Monte Carlo simulation was applied to predict the human exposure risk of SCCPs. Infants and toddlers were at risk of SCCPs based on predicted HQ values, which were exceeded the threshold for neoplastic effects in the worst case. Our results on the occurrences, sources and human exposures of SCCPs will be useful to provide a better understanding of SCCPs behaviors in indoor environment in China, and to support environmental risk evaluation and regulation of SCCPs in the world. Copyright © 2017. Published by Elsevier Ltd.

  3. Evolution of the indoor biome.

    Science.gov (United States)

    Martin, Laura J; Adams, Rachel I; Bateman, Ashley; Bik, Holly M; Hawks, John; Hird, Sarah M; Hughes, David; Kembel, Steven W; Kinney, Kerry; Kolokotronis, Sergios-Orestis; Levy, Gabriel; McClain, Craig; Meadow, James F; Medina, Raul F; Mhuireach, Gwynne; Moreau, Corrie S; Munshi-South, Jason; Nichols, Lauren M; Palmer, Clare; Popova, Laura; Schal, Coby; Täubel, Martin; Trautwein, Michelle; Ugalde, Juan A; Dunn, Robert R

    2015-04-01

    Few biologists have studied the evolutionary processes at work in indoor environments. Yet indoor environments comprise approximately 0.5% of ice-free land area--an area as large as the subtropical coniferous forest biome. Here we review the emerging subfield of 'indoor biome' studies. After defining the indoor biome and tracing its deep history, we discuss some of its evolutionary dimensions. We restrict our examples to the species found in human houses--a subset of the environments constituting the indoor biome--and offer preliminary hypotheses to advance the study of indoor evolution. Studies of the indoor biome are situated at the intersection of evolutionary ecology, anthropology, architecture, and human ecology and are well suited for citizen science projects, public outreach, and large-scale international collaborations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Evaluation of the Impact of Indoor Smoking Bans on Air Quality in Australian Licensed Clubs

    Science.gov (United States)

    Davidson, Margaret Elissa

    .5 particulates with a special calibration factor for environmental tobacco smoke calibration factor of 0.32 (PM2.5 (0.32)) was undertaken in the second group of clubs and monthly monitoring following the bans was undertaken in Clubs 9 and 11. There was a significant reduction in the mean airborne concentrations of PM2.5, PM1.0, PM2.5 (0.32), PPAH, CO and nicotine at all clubs following the implementation of the smoking bans. Of note was the increase in the mean outdoor PM2.5 concentrations at 6 clubs, and the significant increase in the number of outdoor smokers at 8 venues. The greatest change was an increase in the frequency of outdoor PM2.5 concentrations exceeding 25 mum m-3 which is the Australian PM2.5 advisory standard for ambient air (24 hours). Weak to strong significant correlations (R2=0.402-0.757 p=0.000-0.022) were identified between outdoor smokers and indoor PM2.5 concentrations (3 clubs), and a significant correlation (R2=1.000 p=0.000) between nicotine and indoor pollutants at one club. The results of this study indicate that indoor smoking bans may not fully protect the health of the public and workers in venues because of the possible infiltration of environmental tobacco smoke (ETS) identified at three clubs, as well as outdoor exposure to ETS associated with an increase in smoking activity. The lack of current indoor air quality standards makes the interpretation of the post ban air quality data difficult. Although, the mean concentration of contaminants were all below recommended limits for ambient air. The potential infiltration of ETS inside some clubs indicates that air quality may still represent both an occupational and public health risk because ETS has no safe exposure limit (WHO, 2000). (Abstract shortened by ProQuest.).

  5. Integrated Management of Residential Indoor Air Quality: A Call for Stakeholders in a Changing Climate.

    Science.gov (United States)

    Levasseur, Marie-Eve; Poulin, Patrick; Campagna, Céline; Leclerc, Jean-Marc

    2017-11-25

    A paradigm change in the management of environmental health issues has been observed in recent years: instead of managing specific risks individually, a holistic vision of environmental problems would assure sustainable solutions. However, concrete actions that could help translate these recommendations into interventions are lacking. This review presents the relevance of using an integrated indoor air quality management approach to ensure occupant health and comfort. At the nexus of three basic concepts (reducing contaminants at the source, improving ventilation, and, when relevant, purifying the indoor air), this approach can help maintain and improve indoor air quality and limit exposure to several contaminants. Its application is particularly relevant in a climate change context since the evolving outdoor conditions have to be taken into account during building construction and renovation. The measures presented through this approach target public health players, building managers, owners, occupants, and professionals involved in building design, construction, renovation, and maintenance. The findings of this review will help the various stakeholders initiate a strategic reflection on the importance of indoor air quality and climate change issues for existing and future buildings. Several new avenues and recommendations are presented to set the path for future research activities.

  6. Radon level in China and elevated indoor exposure in carbon brick and cave dwellings

    International Nuclear Information System (INIS)

    Wang Zuoyuan

    1992-01-01

    A nation wide survey of Chinese houses was conducted to determine the average annual effective dose to Chinese population from exposure to radon and its daughter products. The indoor and outdoor concentrations of radon and its daughters were measured using scintillation flask, two filter and carbon canister methods, as well as modified Tsivoglou methods for Rn daughters. Average Rn concentrations are 26.2Bqm -3 and 13.5Bqm -3 for indoor and outdoor environment, respectively. Potential alpha energy concentration, indoor is 744 x 10 -10 Jm -3 , outdoor is 511 x 10 -10 Jm -3 . Equilibrium Factor of Rn daughters are 0.49 (indoor) and 0.61 (outdoor). Occupancy Factor is 0.77 and 0.23. Using appropriate conversion factors, the annual average effective dose to Chinese population is 0.967 mSv. And also, the indoor Rn concentration and gamma dose rate were surveyed in two rural Provinces: Gansu and Jianxi. The fact was found that lung cancer mortality of population lived in high Rn level dwellings is higher than in control groups. An epidemiological retrospective case-control study is recommended in houses with high Rn level. (author)

  7. Enhancing integrated indoor/outdoor mobility in a smart campus

    OpenAIRE

    Torres Sospedra, Joaquín; Avariento, Joan; Rambla Risueño, David; Montoliu Colás, Raúl; Casteleyn, Sven; Benedito Bordonau, Mauri; Gould Carlson, Michael; Huerta Guijarro, Joaquín

    2015-01-01

    A Smart City relies on six key factors: Smart Governance, Smart People, Smart Economy, Smart Environment, Smart Living and Smart Mobility. This paper focuses on Smart Mobility by improving one of its key components: positioning. We developed and deployed a novel indoor positioning system (IPS) that is combined with an outdoor positioning system to support seamless indoor and outdoor navigation and wayfinding. The positioning system is implemented as a service in our broader cartography-based ...

  8. Indoor gamma radiation monitoring In Rawalpindi, Pakistan using TLD100

    International Nuclear Information System (INIS)

    Azam, Sana; Tufail, Muhammad; Sohail, Muhammad

    2008-01-01

    Full text: Natural radioactivity originates from extraterrestrial sources as well as from radioactive elements in earth's crust. The amount of radioactivity varies from place to place and with altitude. The aim of this study was to observe the indoor radiation level in Rawalpindi using TLD. For this purpose LiF:Mg:Ti (TLD100) chips were used. Chips were annealed and then calibrated using different sources and the calibration factor obtained by using Cs137 source was selected for dose estimation. Its value was 0.1403 μGy/TL response. Rawalpindi categorized into six regions. In each region, 5 cemented houses were selected and TLD 100 chips were placed at a distance of 0.5 m from ground the level. Chips were properly covered to protect them from ultraviolet light and moisture and were placed for three months. The average annual indoor dose rate for Rawalpindi was estimated to be 392.105μGy/yr and average dose to be 97.65μGy. Therefore, the effective dose for population of Rawalpindi from indoor gamma radiation was estimated to be 313.68μSv/yr using an indoor occupancy factor of 80%. (author)

  9. CSI Frequency Domain Fingerprint-Based Passive Indoor Human Detection

    Directory of Open Access Journals (Sweden)

    Chong Han

    2018-04-01

    Full Text Available Passive indoor personnel detection technology is now a hot topic. Existing methods have been greatly influenced by environmental changes, and there are problems with the accuracy and robustness of detection. Passive personnel detection based on Wi-Fi not only solves the above problems, but also has the advantages of being low cost and easy to implement, and can be better applied to elderly care and safety monitoring. In this paper, we propose a passive indoor personnel detection method based on Wi-Fi, which we call FDF-PIHD (Frequency Domain Fingerprint-based Passive Indoor Human Detection. Through this method, fine-grained physical layer Channel State Information (CSI can be extracted to generate feature fingerprints so as to help determine the state in the scene by matching online fingerprints with offline fingerprints. In order to improve accuracy, we combine the detection results of three receiving antennas to obtain the final test result. The experimental results show that the detection rates of our proposed scheme all reach above 90%, no matter whether the scene is human-free, stationary or a moving human presence. In addition, it can not only detect whether there is a target indoors, but also determine the current state of the target.

  10. Towards the Application of Fuzzy Logic for Developing a Novel Indoor Air Quality Index (FIAQI).

    Science.gov (United States)

    Javid, Allahbakhsh; Hamedian, Amir Abbas; Gharibi, Hamed; Sowlat, Mohammad Hossein

    2016-02-01

    In the past few decades, Indoor Air Pollution (IAP) has become a primary concern to the point. It is increasingly believed to be of equal or greater importance to human health compared to ambient air. However, due to the lack of comprehensive indices for the integrated assessment of indoor air quality (IAQ), we aimed to develop a novel, Fuzzy-Based Indoor Air Quality Index (FIAQI) to bridge the existing gap in this area. We based our index on fuzzy logic, which enables us to overcome the limitations of traditional methods applied to develop environmental quality indices. Fifteen parameters, including the criteria air pollutants, volatile organic compounds, and bioaerosols were included in the FIAQI due mainly to their significant health effects. Weighting factors were assigned to the parameters based on the medical evidence available in the literature on their health effects. The final FIAQI consisted of 108 rules. In order to demonstrate the performance of the index, data were intentionally generated to cover a variety of quality levels. In addition, a sensitivity analysis was conducted to assess the validity of the index. The FIAQI tends to be a comprehensive tool to classify IAQ and produce accurate results. It seems useful and reliable to be considered by authorities to assess IAQ environments.

  11. Tetrabromobisphenol A in Indoor Dust from Houses and Internet Cafes

    Directory of Open Access Journals (Sweden)

    Ma. Pythias B. Espino

    2011-12-01

    Full Text Available Tetrabromobisphenol A or TBBPA is a widely used brominated flame retardant in modern materials such as electronic products, plastics and building materials. TBBPA can leach out of flame retardant-treated products during production, use, reuse, and final disposal of these consumer products. It has thus become a contemporary environmental contaminant. This study reports the levels of TBBPA in indoor dust from houses (n=4 and internet cafes (n=5 in Angono and Quezon City, in the Philippines. TBBPA in indoor dust was analyzed by ultrasonication-assisted hexane extraction and HPLC-UV determination. The instrument and method detection limits were 0.004 ng uL-1 and 1275 ng g-1, respectively. The standard calibration solutions ranged from 0.03 to 0.30 ng uL-1 (r2=0.9956. The extraction recovery was 78% (n=3. TBBPA was found in six of the nine indoor dust samples studied where the concentrations ranged from not detected to 4916 ng g-1. The occurrence and levels of TBBPA in indoor dusts are significant and suggest the need for further investigations especially in other microenvironments where people may be exposed to this contaminant.

  12. Impacts of Changes of Indoor Air Pressure and Air Exchange Rate in Vapor Intrusion Scenarios.

    Science.gov (United States)

    Shen, Rui; Suuberg, Eric M

    2016-02-01

    There has, in recent years, been increasing interest in understanding the transport processes of relevance in vapor intrusion of volatile organic compounds (VOCs) into buildings on contaminated sites. These studies have included fate and transport modeling. Most such models have simplified the prediction of indoor air contaminant vapor concentrations by employing a steady state assumption, which often results in difficulties in reconciling these results with field measurements. This paper focuses on two major factors that may be subject to significant transients in vapor intrusion situations, including the indoor air pressure and the air exchange rate in the subject building. A three-dimensional finite element model was employed with consideration of daily and seasonal variations in these factors. From the results, the variations of indoor air pressure and air exchange rate are seen to contribute to significant variations in indoor air contaminant vapor concentrations. Depending upon the assumptions regarding the variations in these parameters, the results are only sometimes consistent with the reports of several orders of magnitude in indoor air concentration variations from field studies. The results point to the need to examine more carefully the interplay of these factors in order to quantitatively understand the variations in potential indoor air exposures.

  13. Environmental assessment of indoor radon gas exposure health hazards and some of its public risks

    International Nuclear Information System (INIS)

    Hussein, Abd El-Razik. Z.; Ibrahim, M.Se.; Ragab, M.H.; El-Bukhari, M.S.

    2005-01-01

    This study examine the relationship between indoor radon gas exposure and the cancer risk and housing characteristics in lung cancer risk houses (CRH) compared to non lung cancer risk houses (NCRH). Mean radon concentrations measured by active method were significantly higher among CRH compared to NCRH, 9:93 pCi/L versus 4.56 pCi/L, respectively. There was no statistically significant diurnal variation as regards radon levels in all examined houses. Indoor radon concentrations show statistically significance in houses with bad ventilation (low air change rate) compared to houses with good ventilation (high air change rate). Houses with floor material of tiles, had statistically significant higher radon concentrations. Neither finishing wall material nor indoor gas source shows statistically significance as regard radon levels. Radon levels > 4 pCi/L (US EPA action level) were statistically significance higher in bed rooms compared levels in living rooms. High radon concentrations were reported in lung cane risk houses and in houses with bad ventilation

  14. Indoor radon in Tunisian spas

    International Nuclear Information System (INIS)

    Labidi, S.; Al-Azmi, Darwish; Ben Salah, R.

    2012-01-01

    Indoor radon concentrations were measured in four well-known spas of Tunisia using nuclear track detectors. The radon concentrations in these spas were found to be in the range of 19 - 870 Bq.m -3 . The equilibrium factor F between radon and its progeny was found to vary in the range of 0.2 - 0.5, depending upon the ventilation rates within the buildings of the spas. Using the exposure-dose conversion factor, the effective doses to patients and workers were estimated and the dose was found to vary in the range 3.7 x 10 -3 - 12.5 x 10 -3 mSv.y -1 and 0.45 - 1.5 mSv.y -1 for patients and workers, respectively. These values are well inside the limit recommended for the annual dose limit of 20 mSv.y -1 for an occupational worker. The radium content in the groundwater of all four spas was measured and the results showed no correlation between the 226 Ra concentration in water and radon concentration in indoor air of the investigated spas. (authors)

  15. Indoor climate design for a monumental building with incidental high indoor moisture loads

    NARCIS (Netherlands)

    Schijndel, van A.W.M.

    2005-01-01

    The paper presents a study of the indoor climate of a monumental building with periodic high indoor moisture loads. Several scenarios of the past performance and new control classes are simulated and evaluated. The results include the influence of hygric inertia on the indoor climate and

  16. Occurrence, dynamics and reactions of organic pollutants in the indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    Salthammer, Tunga [Material Analysis and Indoor Chemistry, Fraunhofer Wilhelm-Klauditz Institut (WKI), Braunschweig (Germany); Bahadir, Muefit [Institut fuer Oekologische Chemie und Abfallanalytik, Technische Universitaet Braunschweig, Braunschweig (Germany)

    2009-06-15

    The indoor environment is a multidisciplinary scientific field involving chemistry, physics, biology, health sciences, architecture, building sciences and civil engineering. The need for reliable assessment of human exposure to indoor pollutants is attracting increasing attention. This, however, requires a detailed understanding of the relevant compounds, their sources, physical and chemical properties, dynamics, reactions, their distribution among the gas phase, airborne particles and settled dust as well as the availability of modern measurement techniques. Building products, furnishings and other indoor materials often emit volatile and semi-volatile organic compounds. With respect to a healthy indoor environment, only low emitting products, which do not influence indoor air quality in a negative way, should be used in a building. Therefore, materials and products for indoor use need to be evaluated for their chemical emissions. This is routinely done in test chambers and cells. Many studies have shown that the types of sources in occupational and residential indoor environments, the spectrum of emitting compounds and the duration of emission cover a wide range. The demand for standardized test methods under laboratory conditions has resulted in several guidelines for determination of emission rates. Furthermore, it has now been recognized that both primary and secondary emissions may affect indoor air quality. The problem may become more dominant when components of different materials can react with each other or when catalytic materials are applied. Such products derived from indoor related reactions may have a negative impact on indoor air quality due to their low odor threshold, health related properties or the formation of ultrafine particles. Several factors can influence the emission characteristics and numerous investigations have shown that indoor chemistry is of particular importance for the indoor related characterization of building product emissions

  17. The influence of photocatalytic interior paints on indoor air quality

    Science.gov (United States)

    Auvinen, Joonas; Wirtanen, Leif

    2008-06-01

    A clean indoor air is important for the well-being and health of people. Lately, new photocatalytic paints have been launched on the market, which are claimed to have air-purifying effects. Photocatalysis initiates radical reactions. Radicals are formed when a photocatalyst (e.g. TiO2) is subjected to radiation. Typical radicals are the hydroxyl radical (radOH) and the superoxide radical (radO2-). Radicals cause chain reactions, which degrade and decompose organic compounds. The end products of these chain reactions are water and carbon dioxide, if the reactions are fully completed (mineralization). If mineralization does not take place, then a great number of side products can be formed, whose properties are not well understood. The side products of photocatalytic reactions can be permanent and stabile. The decomposition of indoor air impurities on the surface of photocatalytic paints is not obvious. The ability of photocatalytic indoor paints to reduce chemical indoor air impurities is the key issue of this study. Six different paints with different binder systems, such as lime, polyorganic siloxane, silica sol-gel and organic binders, were examined. The experiments were divided into three topics: degradation of an organic binder, photocatalytic decomposition of formaldehyde, and a volatile organic compound (VOC) mixture consisting of five different indoor air VOCs. All tests were carried out in an environmental test chamber under dynamic conditions. The test results indicate that many indoor pollutants are generated under normal- and UVA-light. Typical compounds formed include formaldehyde, acetone, acetaldehyde, etc. A clear decrease of formaldehyde or the VOC mixture concentration was not observed. All possibly generated compounds could not be collected or analyzed in this research project, but the measurements show that photocatalytic reactions do not generate only carbon dioxide and water. Photocatalytic decomposition of indoor air impurities can, however

  18. Indoor air quality scenario in India-An outline of household fuel combustion

    Science.gov (United States)

    Rohra, Himanshi; Taneja, Ajay

    2016-03-01

    Most of the research around the world has been on outdoor air pollution, but in India we have a more severe problem of Indoor Air Pollution (IAP). The foremost factor cited for is burning of fossil fuels for cooking. Among the 70% of the country's rural population, about 80% households rely on biomass fuel making India to top the list of countries with largest population lacking access to cleaner fuel for cooking. 4 million deaths and 5% disability-adjusted life-years is an upshot of exposure to IAP from unhealthy cooking making it globally the most critical environmental risk factor. India alone bears the highest burden (28% needless deaths) among developing countries. Moreover, about ¼ of ambient PM2.5 in the country comes from household cookfuels. These considerations have prompted the discussion of the present knowledge on the disastrous health effects of pollutants emitted by biomass combustion in India. Additionally, Particulate Matter as an indoor air pollutant is highlighted with main focus on its spatial temporal variation and some recent Indian studies are further explored. As there are no specific norms for IAP in India, urgent need has arisen for implementing the strategies to create public awareness. Moreover improvement in ventilation and modification in the pattern of fuel will also contribute to eradicate this national health issue.

  19. Cancer Risk from Common Sources of Indoor Pollution

    Czech Academy of Sciences Publication Activity Database

    Holcátová, I.; Slámová, A.; Valenta, Zdeněk

    2005-01-01

    Roč. 14, - (2005), s. 221-228 ISSN 1420-326X R&D Projects: GA AV ČR(CZ) 1ET200300413 Institutional research plan: CEZ:AV0Z10300504 Keywords : cancer of lung * kidney * oesophagus * multinational study * risk factors * indoor risk factors Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 0.414, year: 2005

  20. Health behaviours associated with indoor tanning based on the 2012/13 Manitoba Youth Health Survey

    Directory of Open Access Journals (Sweden)

    E. Harland

    2016-08-01

    Full Text Available Introduction: Although indoor tanning causes cancer, it remains relatively common among adolescents. Little is known about indoor tanning prevalence and habits in Canada, and even less about associated behaviours. This study explores the prevalence of adolescent indoor tanning in Manitoba and its association with other demographic characteristics and health behaviours. Methods: We conducted secondary analyses of the 2012/13 Manitoba Youth Health Survey data collected from Grade 7 to 12 students (n = 64 174 and examined associations between indoor tanning (whether participants had ever used artificial tanning equipment and 25 variables. Variables with statistically significant associations to indoor tanning were tested for collinearity and grouped based on strong associations. For each group of highly associated variables, the variable with the greatest effect upon indoor tanning was placed into the final logistic regression model. Separate analyses were conducted for males and females to better understand sex-based differences, and analyses were adjusted for age. Results: Overall, 4% of male and 9% of female students reported indoor tanning, and prevalence increased with age. Relationships between indoor tanning and other variables were similar for male and female students. Binary logistic regression models indicated that several variables significantly predicted indoor tanning, including having part-time work, being physically active, engaging in various risk behaviours such as driving after drinking for males and unplanned sex after alcohol/drugs for females, experiencing someone say something bad about one's body shape/size/appearance, identifying as trans or with another gender, consuming creatine/other supplements and, for females only, never/rarely using sun protection. Conclusion: Indoor tanning among adolescents was associated with age, part-time work, physical activity and many consumption behaviours and lifestyle risk factors. Though

  1. Indoor radon level in schools of Shillong, Meghalaya

    International Nuclear Information System (INIS)

    Saxena, A.; Sharma, Y.; Maibam, D.; Walia, D.; Diengdoh, E.

    2010-01-01

    Radon ( 222 Rn) in the atmosphere is the most important contributor to human exposure from natural sources. Radon is a noble inert gas; and it decays to radionuclides that are chemically active and relatively short lived. Inhalation of the short lived radon progeny imparts a radiation dose to the lung, to which an increased risk of lung cancer is attributed due to the alpha particle irradiation of the secretory and basal cells of the respiratory tract. The indoor radon concentration is dependent on the texture, porosity, permeability, water content of the soil underlying the structure and the radon behaviour in soils on aspects of geology and climate. The direct cause of high radon entry rates into structures exhibiting high indoor radon concentrations are fractures in bedrock formations, cracks in the soil, and similar inhomogeneities in the materials of the foundation of the structures. Other factors influencing indoor radon concentration includes exhalations from the walls and ceilings, building design and material, cracks and openings in the foundation of the buildings. The geological factors in the study area promote radon accumulation especially in buildings and dwellings. The world average annual effective dose in the indoor environments is 1.01 mSv.y -1 . The importance of radon level measurements in school buildings is of interest as children are more sensitive to radon exposure than adults. Hence, radon measurements in 10 schools have been undertaken in the present study

  2. Comparative Indoor and Outdoor Degradation of Organic Photovoltaic Cells via Inter-laboratory Collaboration

    OpenAIRE

    Owens, Charles; Ferguson, Gretta; Hermenau, Martin; Voroshazi, Eszter; Galagan, Yulia; Zimmermann, Birger; Rösch, Roland; Angmo, Dechan; Teran-Escobar, Gerardo; Uhrich, Christian; Andriessen, Ronn; Hoppe, Harald; Würfel, Uli; Lira-Cantu, Monica; Krebs, Frederik

    2015-01-01

    We report on the degradation of organic photovoltaic (OPV) cells in both indoor and outdoor environments. Eight different research groups contributed state of the art OPV cells to be studied at Pomona College. Power conversion efficiency and fill factor were determined from IV curves collected at regular intervals over six to eight months. Similarly prepared devices were measured indoors, outdoors, and after dark storage. Device architectures are compared. Cells kept indoors performed better ...

  3. Understanding the origin of radon indoors: Building a predictive capability

    International Nuclear Information System (INIS)

    Sextro, R.G.

    1985-12-01

    Indoor radon concentrations one to two orders of magnitude higher than the US average of ∼60 Bq m -3 (∼1.5 pCi L -1 ) are not uncommon, and concentrations greater than 4000 Bq m -3 have been observed in houses in areas with no known artificially-enhanced radon sources. In general, source categories for indoor radon are well known: soil, domestic water, building materials, outdoor air, and natural gas. Soil is thought to be a major source of indoor radon, either through molecular diffusion (usually a minor component) or convective flow of soil gas. While soil gas flow into residences has been demonstrated, no detailed understanding of the important factors affecting the source strength of radon from soil has yet emerged. Preliminary work in this area has identified a number of likely issues, including the concentration of radium in the soil, the emanating fraction, soil type, soil moisture content, and other factors that would influence soil permeability and soil gas transport. Because a significant number of dwellings are expected to have indoor radon concentrations above guideline levels, a predictive capability is needed that would help identify geographical areas having the potential for high indoor concentrations. This paper reviews the preliminary work that has been done to identify important soil and building characteristics that influence the migration of radon and outlines the areas of further research necessary for development of a predictive method. 32 refs., 4 figs

  4. Indoor aerosol modeling for assessment of exposure and respiratory tract deposited dose

    Science.gov (United States)

    Hussein, Tareq; Wierzbicka, Aneta; Löndahl, Jakob; Lazaridis, Mihalis; Hänninen, Otto

    2015-04-01

    Air pollution is one of the major environmental problems that influence people's health. Exposure to harmful particulate matter (PM) occurs both outdoors and indoors, but while people spend most of their time indoors, the indoor exposures tend to dominate. Moreover, higher PM concentrations due to indoor sources and tightness of indoor environments may substantially add to the outdoor originating exposures. Empirical and real-time assessment of human exposure is often impossible; therefore, indoor aerosol modeling (IAM) can be used as a superior method in exposure and health effects studies. This paper presents a simple approach in combining available aerosol-based modeling techniques to evaluate the real-time exposure and respiratory tract deposited dose based on particle size. Our simple approach consists of outdoor aerosol data base, IAM simulations, time-activity pattern data-base, physical-chemical properties of inhaled aerosols, and semi-empirical deposition fraction of aerosols in the respiratory tract. These modeling techniques allow the characterization of regional deposited dose in any metric: particle mass, particle number, and surface area. The first part of this presentation reviews recent advances in simple mass-balance based modeling methods that are needed in analyzing the health relevance of indoor exposures. The second part illustrates the use of IAM in the calculations of exposure and deposited dose. Contrary to previous methods, the approach presented is a real-time approach and it goes beyond the exposure assessment to provide the required information for the health risk assessment, which is the respiratory tract deposited dose. This simplified approach is foreseen to support epidemiological studies focusing on exposures originating from both indoor and outdoor sources.

  5. Indoor Air Quality in the Metro System in North Taiwan

    Directory of Open Access Journals (Sweden)

    Ying-Yi Chen

    2016-12-01

    Full Text Available Indoor air pollution is an increasing health concern, especially in enclosed environments such as underground subway stations because of increased global usage by urban populations. This study measured the indoor air quality of underground platforms at 10 metro stations of the Taipei Rapid Transit system (TRTS in Taiwan, including humidity, temperature, carbon monoxide (CO, carbon dioxide (CO2, formaldehyde (HCHO, total volatile organic compounds (TVOCs, ozone (O3, airborne particulate matter (PM10 and PM2.5, bacteria and fungi. Results showed that the CO2, CO and HCHO levels met the stipulated standards as regulated by Taiwan’s Indoor Air Quality Management Act (TIAQMA. However, elevated PM10 and PM2.5 levels were measured at most stations. TVOCs and bacterial concentrations at some stations measured in summer were higher than the regulated standards stipulated by Taiwan’s Environmental Protection Administration. Further studies should be conducted to reduce particulate matters, TVOCs and bacteria in the air of subway stations.

  6. Indoor Air Quality in the Metro System in North Taiwan.

    Science.gov (United States)

    Chen, Ying-Yi; Sung, Fung-Chang; Chen, Mei-Lien; Mao, I-Fang; Lu, Chung-Yen

    2016-12-02

    Indoor air pollution is an increasing health concern, especially in enclosed environments such as underground subway stations because of increased global usage by urban populations. This study measured the indoor air quality of underground platforms at 10 metro stations of the Taipei Rapid Transit system (TRTS) in Taiwan, including humidity, temperature, carbon monoxide (CO), carbon dioxide (CO₂), formaldehyde (HCHO), total volatile organic compounds (TVOCs), ozone (O₃), airborne particulate matter (PM 10 and PM 2.5 ), bacteria and fungi. Results showed that the CO₂, CO and HCHO levels met the stipulated standards as regulated by Taiwan's Indoor Air Quality Management Act (TIAQMA). However, elevated PM 10 and PM 2.5 levels were measured at most stations. TVOCs and bacterial concentrations at some stations measured in summer were higher than the regulated standards stipulated by Taiwan's Environmental Protection Administration. Further studies should be conducted to reduce particulate matters, TVOCs and bacteria in the air of subway stations.

  7. Impact of ventilation systems and energy savings in a building on the mechanisms governing the indoor radon activity concentration.

    Science.gov (United States)

    Collignan, Bernard; Powaga, Emilie

    2017-11-23

    For a given radon potential in the ground and a given building, the parameters affecting the indoor radon activity concentration (IRnAC) are indoor depressurization of a building and its air change rate. These parameters depend mainly on the building characteristics, such as airtightness, and on the nature and performances of the ventilation system. This study involves a numerical sensitivity assessment of the indoor environmental conditions on the IRnAC in buildings. A numerical ventilation model has been adapted to take into account the effects of variations in the indoor environmental conditions (depressurization and air change rate) on the radon entry rate and on the IRnAC. In the context of the development of a policy to reduce energy consumption in a building, the results obtained showed that IRnAC could be strongly affected by variations in the air permeability of the building associated with the ventilation regime. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. A statistical procedure for the qualification of indoor dust

    International Nuclear Information System (INIS)

    Scapin, Valdirene O.; Scapin, Marcos A.; Ribeiro, Andreza P.; Sato, Ivone M.

    2009-01-01

    The materials science advance has contributed to the humanity. Notwithstanding, serious environmental and human health problems are often observed. Thereby, many worldwide researchers have focused their work to diagnose, assess and monitor several environmental systems. In this work, a statistical procedure (on a 0.05 significance level) that allows verifying if indoor dust samples have characteristics of soil/sediment is presented. Dust samples were collected from 69 residences using a domestic vacuum cleaner in four neighborhoods of the Sao Paulo metropolitan region, Brazil, between 2006 and 2008. The samples were sieved in the fractions of 150-75 (C), 75-63 (M) and <63 μm (F). The elemental concentrations were determined by X-ray fluorescence (WDXRF). Afterwards, the indoor samples results (group A) were compared to the group of 109 certificated reference materials, which included different kinds of geological matrices, such as clay, sediment, sand and sludge (group B) and to the continental crust values (group C). Initially, the Al/Si ratio was calculated for the groups (A, B, C). The variance analysis (ANOVA), followed by Tukey test, was used to find out if there was a significant difference between the concentration means of the considered groups. According to the statistical tests; the group B presented results that are considered different from others. The interquartile range (IQR) was used to detected outlier values. ANOVA was applied again and the results (p ≥ 0.05) showed equality between ratios means of the three groups. Accordingly, the results suggest that the indoor dust samples have characteristic of soil/sediment. The statistical procedure may be used as a tool to clear the information about contaminants in dust samples, since they have characteristic of soil and may be compared with values reported by environmental control organisms. (author)

  9. Current Indoor Air Quality in Japan.

    Science.gov (United States)

    Jinno, Hideto

    2016-01-01

    People spend more than two thirds of their daily time indoors. Hence, maintaining a healthy indoor environment is indispensable for the prevention of building related illness. In Japan, guidelines for indoor air quality have been established for 13 volatile/semi-volatile organic compounds (VOCs/SVOCs). These guidelines are now under revision by the Committee on Sick House Syndrome: Indoor Air Pollution. In order to gain information on the current indoor air pollutants and their levels, we carried out a nation-wide survey of VOCs and aldehydes in indoor residential air during 2012-2013. In this review, I concisely summarized the current indoor air quality of Japan.

  10. Categories of adverse health effects from indoor air pollution

    International Nuclear Information System (INIS)

    Weetman, D.F.; Munby, J.

    1994-01-01

    There is a lack of precision in the definition of health, which leads to confusion in the assessment of adverse effects arising from indoor air pollution. Adverse health effects range from annoyance to life-threatening conditions. Survey responses suggest that males and females differ in their perception of a healthy person, but both sexes envisage a male in terms of positive fitness, strength, energy and the possession of an athletic body, rather than how long one was likely to live. Psychological fitness was relatively unimportant in describing the health of others, but was rates as very important with respect to one's own health. Mortality statistics tend to obscure the proportion of the population who suffer chronic illness that is not life threatening. Although health is largely determined by genetic constitution, lifestyle and environmental factors, the morale of an individual is also important. A new classification of the adverse effects on health of indoor air pollution is proposed: this includes 'comfort' responses, such as sick building syndrome (category 1); acute chemical effects, the nature of which depends upon the specific intoxicant (category 2B), and perceived chronic grave risk, including cancer causation (category 3). The magnitude of risk in this latter category is imprecise, because its measurement involves the technique of quantitative risk assessment. (author) 1 fig., 2 tabs., 158 refs

  11. Indoor air pollution

    International Nuclear Information System (INIS)

    Anwar, J.; Hussain, F.

    2005-01-01

    Indoor air pollution after being a neglected subject for a number of years, is attracting attention recently because it is a side effect of energy crisis. About 50% of world's 6 billion population, mostly in developing countries, depend on biomass and coal in the form of wood, dung and crop residues for domestic energy because of poverty. These materials are burnt in simple stoves with incomplete combustion and infants, children and women are exposed to high levels of indoor air pollution for a considerable period, approximately between 2-4 hours daily. Current worldwide trade in wood fuel is over US $7 billion and about 2 million people are employed full time in production and marketing it. One of the most annoying and common indoor pollutant in both, developing and developed countries, is cigarette smoke. Children in gas-equipped homes had higher incidences of respiratory disease. Babies' DNA can be damaged even before they are born if their mothers breathe polluted air. Exposure to indoor air pollution may be responsible for nearly 2 million excess deaths in developing countries and for 4% of the global burden of the disease. Only a few indoor pollutants have been studied in detail. Indoor air pollution is a major health threat on which further research is needed to define the extent of the problem more precisely and to determine solutions by the policy-makers instead of neglecting it because sufferers mostly belong to Third World countries. (author)

  12. Investigations into the indoor environment and respiratory health in Boston public housing.

    Science.gov (United States)

    Hynes, H Patricia; Brugge, Doug; Osgood, Neal-Dra; Snell, John; Vallarino, Jose; Spengler, John

    2004-01-01

    The self-reported prevalence of asthma in the United States increased by 75% from 1980 to 1994, a trend found to be significant and evident in every region of the country. The increase was most marked in children from birth to 14 years of age; and growing evidence indicates that, as with lead poisoning, inner-city and urban populations are most at risk. Attention has turned to the role of indoor environmental risk factors, especially in homes and schools. Such factors include moisture and mold growth, pest infestation, dust mites, the building envelope, heating systems, inadequate ventilation, nitrogen dioxide, and environmental tobacco smoke. The Healthy Public Housing Initiative (HPHI) is a Boston-based community-centered research and intervention project designed to engage Boston Housing Authority residents in a collaborative process to improve respiratory health, quality of life, building conditions, and building maintenance in public housing. This article summarizes the significant research findings from four pilot studies in housing developments that laid the foundation for the larger HPHI asthma-related environmental intervention study. The research design for the pilot projects is informed by principles of community-collaborative research. The strengths of this model of research for our work are also discussed.

  13. Factors Contributing to Use of Biomass as Domestic Fuel and ...

    African Journals Online (AJOL)

    Biomass energy dominates household cooking energy in developing countries and Nigeria is not exceptional. However, a number of implications such as indoor air pollution, environmental degradation and social burden have been associated with the use of biomass energy. The paper discusses factors that determine the ...

  14. Smartphone-Based Indoor Pedestrian Tracking Using Geo-Magnetic Observations

    Directory of Open Access Journals (Sweden)

    Sungnam Lee

    2013-01-01

    Full Text Available With the widespread use of smartphones, the use of location-based services (LBS with smartphones has become an active research issue. The accurate measurement of user location is necessary to provide LBS. While outdoor locations are easily obtained with GPS, indoor location information is difficult to acquire. Previous work on indoor location tracking systems often relied on infrastructures that are influenced by environmental changes and temporal differences. Several studies have proposed infrastructure-less systems that are independent of the surroundings, but these works generally required non-trivial computation time or energy costs. In this paper, we propose an infrastructure-less pedestrian tracking system in indoor environments. The system uses accelerometers and magnetic sensors in smartphones without pre-installed infrastructure. We reduced the cumulative error of location tracking by geo-magnetic observations at corners and spots with magnetic fluctuations. In addition, we developed a robust estimation model that is tolerant to false positives, as well as a mobility model that reflects the characteristics of multiple sensors. Extensive evaluation in a real environment indicates that our system is accurate and cost-effective.

  15. An integrated model of environmental factors in adult asthma lung function and disease severity: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Katz Patricia P

    2010-05-01

    Full Text Available Abstract Background Diverse environmental exposures, studied separately, have been linked to health outcomes in adult asthma, but integrated multi-factorial effects have not been modeled. We sought to evaluate the contribution of combined social and physical environmental exposures to adult asthma lung function and disease severity. Methods Data on 176 subjects with asthma and/or rhinitis were collected via telephone interviews for sociodemographic factors and asthma severity (scored on a 0-28 point range. Dust, indoor air quality, antigen-specific IgE antibodies, and lung function (percent predicted FEV1 were assessed through home visits. Neighborhood socioeconomic status, proximity to traffic, land use, and ambient air quality data were linked to the individual-level data via residential geocoding. Multiple linear regression separately tested the explanatory power of five groups of environmental factors for the outcomes, percent predicted FEV1 and asthma severity. Final models retained all variables statistically associated (p Results Mean FEV1 was 85.0 ± 18.6%; mean asthma severity score was 6.9 ± 5.6. Of 29 variables screened, 13 were retained in the final model of FEV1 (R2 = 0.30; p 2 = 0.16; p 1 as an independent variable to the severity model further increased its explanatory power (R2 = 0.25. Conclusions Multivariate models covering a range of individual and environmental factors explained nearly a third of FEV1 variability and, taking into account lung function, one quarter of variability in asthma severity. These data support an integrated approach to modeling adult asthma outcomes, including both the physical and the social environment.

  16. Pollution sources for indoor PM2.5 at the platform in subway station using a positive matrix factorization and an instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jong Myoung; Moon, Jong Hwa; Chung, Yong Sam [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Jin Hong [Chungnam National University, Daejeon (Korea, Republic of)

    2010-05-15

    Airborne particulate matters, especially the PM2.5 (aerodynamic equivalent diameter, AED, less than 2.5 )m) fraction has been important. This is because of their potential for deposition on to the human respiratory system being accompanied by many harmful trace metals (such as As, Cd, Cr, Cu, Mn, Pb, Se, and Zn). As most people spend more than 80% of their time indoors, indoor air quality (IAQ) can exert a considerable impact on the inhalation condition of toxic substances. Therefore, assessment of the absolute concentration levels and elemental composition of PM in an indoor environment such as subway station can be used as a practical barometer of IAQ. The contaminants originated from the indoor pollution sources as well as various outdoor sources are easily accumulated in indoor environment dissimilar to the outdoor. Especially, since the natural ventilation is nearly impossible in the subway station, its pollution status can be worsened under the circumstance that contaminants are constantly originated and circulated inside of station by the repetitive action of subway trains. In this study, a total of 60 PM2.5 samples were collected for 4 seasonal campaigns in 2009 with a low-volume air sampler at one subway station in Daejeon, Korea. We undertook the measurements of up to 25 elements in PM2.5 using an instrumental neutron activation analysis (INAA) and X-ray fluorescence (XRF). And inorganic ion species (SO{sub 4}{sup 2-}, NO{sub 3}{sup -}, NH{sub 4}{sup +}) also were determined by ion chromatography (IC). Next, sources at indoor/outdoor environment were identified and the contributions of each source were quantified by positive matrix factorization (PMF).

  17. Pollution sources for indoor PM2.5 at the platform in subway station using a positive matrix factorization and an instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lim, Jong Myoung; Moon, Jong Hwa; Chung, Yong Sam; Lee, Jin Hong

    2010-01-01

    Airborne particulate matters, especially the PM2.5 (aerodynamic equivalent diameter, AED, less than 2.5 )m) fraction has been important. This is because of their potential for deposition on to the human respiratory system being accompanied by many harmful trace metals (such as As, Cd, Cr, Cu, Mn, Pb, Se, and Zn). As most people spend more than 80% of their time indoors, indoor air quality (IAQ) can exert a considerable impact on the inhalation condition of toxic substances. Therefore, assessment of the absolute concentration levels and elemental composition of PM in an indoor environment such as subway station can be used as a practical barometer of IAQ. The contaminants originated from the indoor pollution sources as well as various outdoor sources are easily accumulated in indoor environment dissimilar to the outdoor. Especially, since the natural ventilation is nearly impossible in the subway station, its pollution status can be worsened under the circumstance that contaminants are constantly originated and circulated inside of station by the repetitive action of subway trains. In this study, a total of 60 PM2.5 samples were collected for 4 seasonal campaigns in 2009 with a low-volume air sampler at one subway station in Daejeon, Korea. We undertook the measurements of up to 25 elements in PM2.5 using an instrumental neutron activation analysis (INAA) and X-ray fluorescence (XRF). And inorganic ion species (SO 4 2- , NO 3 - , NH 4 + ) also were determined by ion chromatography (IC). Next, sources at indoor/outdoor environment were identified and the contributions of each source were quantified by positive matrix factorization (PMF).

  18. Indoor air quality and the law in Singapore.

    Science.gov (United States)

    Chan, P

    1999-12-01

    With the greater use of air-conditioned offices in Singapore, achieving good indoor air quality has become an important issue. The laws that impose duties upon designers and contractors with respect to the design and construction of air-conditioning and mechanical ventilation (ACMV) systems are set out in the Building Control Regulations and the Singapore Standard Code of Practice for Mechanical Ventilation and Air-conditioning in Buildings (hereinafter "SS CP 13:1980"). ACMV maintenance is governed by the Environmental Public Health Act, the Building and Common Property (Maintenance and Management) Act, and the Land Titles (Strata) Act, as well as by lease or tenancy agreements. Designers, contractors, developers, building owners and management corporations may also be liable to the workers, occupants and other premises users for indoor air quality (IAQ)-related injuries under the general principles of contract and tort. Recently, the Guidelines for Good Indoor Air Quality in Office Premises was issued by the Ministry of Environment to complement SS CP 13:1980 toward improving the indoor air quality of air-conditioned office premises. Although the Guidelines have no statutory effect, they may be adopted as contractual requirements in construction, lease and maintenance contracts. They may also be used to determine the relevant standard of duty of care required to discharge tortious liability. This paper looks at the existing laws and rules affecting the design, construction and maintenance of air-conditioned offices in light of Part III of the Ministry's Guidelines.

  19. Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China

    Directory of Open Access Journals (Sweden)

    Zhen Peng

    2017-07-01

    Full Text Available Over 70% of a pupil’s school life is spent inside a classroom, and indoor air quality has a significant impact on students’ attendance and learning potential. Therefore, the indoor air quality in primary school buildings is highly important. This empirical study investigates the indoor air quality in four naturally ventilated schools in China, with a focus on four parameters: PM2.5, PM10, CO2, and temperature. The correlations between the indoor air quality and the ambient air pollution, building defects, and occupants’ activities have been identified and discussed. The results indicate that building defects and occupants’ activities have a significant impact on indoor air quality. Buildings with better air tightness have a relatively smaller ratio of indoor particulate matter (PM concentrations to outdoor PM concentrations when unoccupied. During occupied periods, the indoor/outdoor (I/O ratio could be larger than 1 due to internal students’ activities. The indoor air temperature in winter is mainly determined by occupants’ activities and the adiabatic ability of a building’s fabrics. CO2 can easily exceed 1000 ppm on average due to the closing of windows and doors to keep the inside air warmer in winter. It is concluded that improving air tightness might be a way of reducing outdoor air pollutants’ penetration in naturally ventilated school buildings. Mechanical ventilation with air purification could be also an option on severely polluted days.

  20. Indoor environmental exposures for children with asthma enrolled in the HEAL study, post-Katrina New Orleans.

    Science.gov (United States)

    Grimsley, L Faye; Chulada, Patricia C; Kennedy, Suzanne; White, LuAnn; Wildfire, Jeremy; Cohn, Richard D; Mitchell, Herman; Thornton, Eleanor; El-Dahr, Jane; Mvula, Mosanda M; Sterling, Yvonne; Martin, William J; Stephens, Kevin U; Lichtveld, Maureen

    2012-11-01

    Rain and flooding from Hurricane Katrina resulted in widespread growth of mold and bacteria and production of allergens in New Orleans, Louisiana, which may have led to increased exposures and morbidity in children with asthma. The goal of the Head-off Environmental Asthma in Louisiana (HEAL) study was to characterize post-Katrina exposures to mold and allergens in children with asthma. The homes of 182 children with asthma in New Orleans and surrounding parishes were evaluated by visual inspection, temperature and moisture measurements, and air and dust sampling. Air was collected using vacuum-pump spore traps and analyzed for > 30 mold taxa using bright field microscopy. Dust was collected from the children's beds and bedroom floors and analyzed for mouse (Mus m 1), dust mite (Der p 1), cockroach (Bla g 1), and mold (Alternaria mix) allergens using ELISA. More than half (62%) of the children were living in homes that had been damaged by rain, flooding, or both. Geometric mean indoor and outdoor airborne mold levels were 501 and 3,958 spores/m3, respectively. Alternaria antigen was detected in dust from 98% of homes, with 58% having concentrations > 10 µg/g. Mus m 1, Der p 1, and Bla g 1 were detected in 60%, 35%, and 20% of homes, respectively, at low mean concentrations. Except for Alternaria antigen in dust, concentrations of airborne mold (ratio of indoor to outdoor mold) and dust allergens in the homes of HEAL children were lower than measurements found in other studies, possibly because of extensive post-Katrina mold remediation and renovations, or because children moved into cleaner homes upon returning to New Orleans.

  1. Ozone (Environmental Health Student Portal)

    Science.gov (United States)

    Skip Navigation National Library of Medicine Environmental Health Student Portal Connecting Middle School Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor ...

  2. Pesticides (Environmental Health Student Portal)

    Science.gov (United States)

    Skip Navigation National Library of Medicine Environmental Health Student Portal Connecting Middle School Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor ...

  3. Reflections on the history of indoor air science, focusing on the last 50 years.

    Science.gov (United States)

    Sundell, J

    2017-07-01

    The scientific articles and Indoor Air conference publications of the indoor air sciences (IAS) during the last 50 years are summarized. In total 7524 presentations, from 79 countries, have been made at Indoor Air conferences held between 1978 (49 presentations) and 2014 (1049 presentations). In the Web of Science, 26 992 articles on indoor air research (with the word "indoor" as a search term) have been found (as of 1 Jan 2016) of which 70% were published during the last 10 years. The modern scientific history started in the 1970s with a question: "did indoor air pose a threat to health as did outdoor air?" Soon it was recognized that indoor air is more important, from a health point of view, than outdoor air. Topics of concern were first radon, environmental tobacco smoke, and lung cancer, followed by volatile organic compounds, formaldehyde and sick building syndrome, house dust-mites, asthma and allergies, Legionnaires disease, and other airborne infections. Later emerged dampness/mold-associated allergies and today's concern with "modern exposures-modern diseases." Ventilation, thermal comfort, indoor air chemistry, semi-volatile organic compounds, building simulation by computational fluid dynamics, and fine particulate matter are common topics today. From their beginning in Denmark and Sweden, then in the USA, the indoor air sciences now show increasing activity in East and Southeast Asia. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Particle size: a missing factor in risk assessment of human exposure to toxic chemicals in settled indoor dust.

    Science.gov (United States)

    Cao, Zhi-Guo; Yu, Gang; Chen, Yong-Shan; Cao, Qi-Ming; Fiedler, Heidelore; Deng, Shu-Bo; Huang, Jun; Wang, Bin

    2012-11-15

    For researches on toxic chemicals in settled indoor dust, selection of dust fraction is a critical influencing factor to the accuracy of human exposure risk assessment results. However, analysis of the selection of dust fraction in recent studies revealed that there is no consensus. This study classified and presented researches on distribution of toxic chemicals according to dust particle size and on relationship between dust particle size and human exposure possibility. According to the literature, beyond the fact that there were no consistent conclusions on particle size distribution of adherent fraction, dust with particle size less than 100 μm should be paid more attention and that larger than 250 μm is neither adherent nor proper for human exposure risk assessment. Calculation results based on literature data show that with different selections of dust fractions, analytical results of toxic chemicals would vary up to 10-fold, which means that selecting dust fractions arbitrarily will lead to large errors in risk assessment of human exposure to toxic chemicals in settled dust. Taking into account the influence of dust particle size on risk assessment of human exposure to toxic chemicals, a new methodology for risk assessment of human exposure to toxic chemicals in settled indoor dust is proposed and human exposure parameter systems to settled indoor dust are advised to be established at national and regional scales all over the world. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Contributions to indoor gamma dose rate from building materials

    International Nuclear Information System (INIS)

    Liu Xionghua; Li Guangming; Yang Xiangdong

    1990-01-01

    In the coures of construction of a building structured with bricks and concrets, the indoor gamma air absorbed dose rates were seperately measured from the floors, brick walls and prefabricated plates of concrets, etc.. It suggested that the indoor gamma dose rates from building materials are mainly attributed to the brick walls and the floors. A little contribution comes from other brilding materials. The dose rates can be calculated through a 4π-infinite thick model with a correction factor of 0.52

  6. Development of Indoor Air Pollution Concentration Prediction by Geospatial Analysis

    Directory of Open Access Journals (Sweden)

    Adyati Pradini Yudison

    2015-07-01

    Full Text Available People living near busy roads are potentially exposed to traffic-induced air pollutants. The pollutants may intrude into the indoor environment, causing health risks to the occupants. Prediction of pollutant exposure therefore is of great importance for impact assessment and policy making related to environmentally sustainable transport. This study involved the selection of spatial interpolation methods that can be used for prediction of indoor air quality based on outdoor pollutant mapping without indoor measurement data. The research was undertaken in the densely populated area of Karees, Bandung, Indonesia. The air pollutant NO2 was monitored in this area as a preliminary study. Nitrogen dioxide concentrations were measured by passive diffusion tube. Outdoor NO2 concentrations were measured at 94 locations, consisting of 30 roadside and 64 outdoor locations. Residential indoor NO2 concentrations were measured at 64 locations. To obtain a spatially continuous air quality map, the spatial interpolation methods of inverse distance weighting (IDW and Kriging were applied. Selection of interpolation method was done based on the smallest root mean square error (RMSE and standard deviation (SD. The most appropriate interpolation method for outdoor NO2 concentration mapping was Kriging with an SD value of 5.45 µg/m3 and an RMSE value of 5.45 µg/m3, while for indoor NO2 concentration mapping the IDW was best fitted with an RMSE value of 5.92 µg/m3 and an SD value of 5.92 µg/m3.

  7. Energy upgrading measures improve also indoor climate

    DEFF Research Database (Denmark)

    Foldbjerg, Peter; Knudsen, Henrik Nellemose

    2014-01-01

    A new survey shows that the economy is what motivates Danish owners of single-family houses the most to start energy upgrading, and that improved indoor climate is also an important factor. After the upgrading, homeowners experience both improved economy and indoor climate. In a strategy...... to increase the number of homeowners who venture into a major energy upgrading of their house, the demonstrated positive side effects, more than energy savings, should be included in the communication to motivate homeowners. The barriers should be reduced by “taking the homeowners by the hand” and helping...... them to choose relevant energy-saving solutions as well as clarifying the financial consequences and opportunities....

  8. Indoor air problems in Asia

    International Nuclear Information System (INIS)

    Leslie, G.B.

    1995-01-01

    Respiratory disease and mortality due to indoor air pollution are amongst the greatest environmental threats to health in the developing countries of Asia. World-wide, acute respiratory infection is the cause of death of at least 5 million children under the age of 5 every year. The World Bank has claimed that smoke from biomass fuels resulted in an estimated 4 million deaths annually amongst infants and children. Most of these deaths occur in developing countries. Combustion in its various forms must head the list of pollution sources in Asia. Combustion of various fuels for domestic heating, lighting and cooking comprises the major source of internally generated pollutants and combustion in industrial plants, power generation and transportation is the major cause of externally generated pollutants. The products of pyrolysis and combustion include many compounds with well-known adverse health effects. These include gases such as CO, CO 2 , NO x and SO 2 , volatile organic compounds such as polynuclear aromatic hydrocarbons and nitroamines as well as respirable particulates of variable composition. The nature and magnitude of the health risks posed by these materials vary with season, climate, location housing, method of ventilation, culture and socio-economic status. The most important cause of lung cancer in non-smokers in Northern Asia is the domestic combustion of smoky coal. Acute carbon monoxide poisoning is common in many Asian countries. Roads traffic exhaust pollution is worse in the major cities of South East Asia than almost anywhere else in the world and this externally generated air pollution forms the indoor air for the urban poor. Despite all these major problems there has been a tendency for international agencies to focus attention and resources on the more trivial problems of indoor air encountered in the affluent countries of the West. Regulatory agencies in Asia have been too frequently persuaded that their problems of indoor air pollution are

  9. Cross-Sectional Associations between Home Environmental Factors and Domain-Specific Sedentary Behaviors in Adults: The Moderating Role of Socio-Demographic Variables and BMI.

    Science.gov (United States)

    Compernolle, Sofie; Busschaert, Cedric; De Bourdeaudhuij, Ilse; Cardon, Greet; Chastin, Sebastien F M; Van Cauwenberg, Jelle; De Cocker, Katrien

    2017-10-31

    Despite the negative health effects of too much sitting, the majority of adults are too sedentary. To develop effective interventions, insight is needed into home environmental correlates of adults' sedentary behaviors, and into the susceptibility of population subgroups to these home environmental cues. In total, 559 Flemish adults reported socio-demographics, weight and height, home environmental factors and domain-specific sedentary behaviors. Generalized linear modeling was conducted to examine main associations between home environmental factors and domain-specific sedentary behaviors, and to test the moderating role of socio-demographics and BMI on these associations. In case of significant interactions, stratified analyses were performed. Results showed that, among those who did use a computer/laptop during the last week, a one-unit increase in the number of computers or laptops was associated with 17% (OR = 1.17; 95% CI = 1.02, 1.34) and 24% (OR = 1.24; 95% CI = 1.08, 1.43) more minutes computer time per day, respectively. The proximity of the remote controller ( p vehicles (95% CI = 0.001, 0.12) was positively associated with the odds of participation in transport-related sitting time. The latter two associations were moderated by BMI, with significant positive associations limited to those not overweight. To conclude, home environmental factors were associated with domain-specific sedentary behaviors, especially in healthy weight adults. If confirmed by longitudinal studies, public health professionals should encourage adults to limit the number of indoor entertainment devices and motorized vehicles.

  10. Indoor air quality handbook: for designers, builders, and users of energy efficient residences

    International Nuclear Information System (INIS)

    1982-09-01

    The purpose of this handbook is to assist designers, builders, and users of energy efficient residences to achieve the goals of energy efficiency and maintenance of high indoor air quality simultaneously. The handbook helps in identifying and controlling potential problems of indoor air quality. It identifies sources and discusses effective ways to decrease concentrations of air contaminants. It focuses on indoor air quality in both single and multifamily energy-efficient residences. Information about commercial structures such as hospitals and office buildings is presented when it also applies to residences. Basic concepts of contaminants and their concentrations, sources and removal mechanisms, contaminant distribution, heat transfer, and air exchange are discussed. The effects of the building system on indoor air quality are examined. The effects of the external environment, building envelope, environmental control systems, interior design, furnishings, and inhabitants on the emission, dispersion, and removal of indoor air contaminants as well as direct and indirect effects of energy-efficient features are discussed. The health effects of specific air contaminants and the health standards developed for them are examined. Available methods for predicting and measuring contaminants and for evaluating human responses are discussed. Methods and equipment available for the control of indoor air pollution once the contaminants have been identified are also evaluated. The potential legal aspects, including regulatory intervention and civil lawsuits, of failure to evaluate and control indoor air pollution are discussed. A list of references, a glossary, and an index are also included

  11. Assessment of Thailand indoor set-point impact on energy consumption and environment

    International Nuclear Information System (INIS)

    Yamtraipat, N.; Khedari, J.; Hirunlabh, J.; Kunchornrat, J.

    2006-01-01

    The paper presents an investigation of indoor set-point standard of air-conditioned spaces as a tool to control electrical energy consumption of air-conditioners in Thailand office buildings and to reduce air pollutants. One hundred and forty-seven air-conditioned rooms in 13 buildings nationwide were used as models to analyze the electricity consumption of air-conditioning systems according to their set indoor temperatures, which were below the standard set-point and were accounted into a large scale. Then, the electrical energy and environmental saving potentials in the country were assessed by the assumption that adaptation of indoor set-point temperature is increased up to the standard set-point of 26 o C. It was concluded that the impacts of indoor set-point of air-conditioned rooms, set at 26 o C, on energy saving and on environment are as follows: The overall electricity consumption saving would be 804.60 GWh/year, which would reduce the corresponding GHGs emissions (mainly CO 2 ) from power plant by 579.31x10 3 tons/year

  12. Airflow characteristics and pollution distribution around a thermal manikin - Impact of specific personal and indoor environmental factors

    DEFF Research Database (Denmark)

    Licina, Dusan; Tham, Kwok Wai; Melikov, Arsen Krikor

    2016-01-01

    , and ventilation flow considerably affected airflow characteristics and pollution distribution around the thermal manikin. Under the specific set of conditions studied, the most favorable airflow patterns in preventing the feet pollution from reaching the breathing zone was transverse flow from the front......This study presents a summary of experimental measurements on the airflow characteristics and pollution distribution around a non-breathing thermal manikin. The two objectives are: (1) to examine the extent to which personal (body posture, clothing insulation, table positioning) and environmental...... factors (room air temperature and ventilation flow) affect the airflow characteristic (velocity and temperature) around the thermal manikin and (2) to examine the pollution distribution within the convective boundary layer (CBL) around a thermal manikin and personal exposure to two types of airborne...

  13. Indoor air quality: The hidden side of the indoor environment

    NARCIS (Netherlands)

    Oliveira Fernandes, E. de; Bluyssen, P.M.; Clausen, G.H.

    1996-01-01

    The physical environment can be defined and understood in manv different ways, both from its nature, e.g., thermal, accoustic, etc., or its dimension, e.g., global, local, urban, indoors. The indoor environment is much more than the space or the light effects; it is the result of a complex

  14. Health Risk Assessment of Indoor Air Quality, Socioeconomic and House Characteristics on Respiratory Health among Women and Children of Tirupur, South India

    Directory of Open Access Journals (Sweden)

    Krassi Rumchev

    2017-04-01

    Full Text Available Background: Indoor air pollution is still considered as one of the leading causes of morbidity and mortality worldwide and especially in developing countries, including India. This study aims to assess social, housing, and indoor environmental factors associated with respiratory health among mothers and children. Methods: The study was conducted in the city of Tirupur, South India. We quantitatively assessed the indoor exposure to fine particulate matter (PM2.5 and carbon monoxide in relation to respiratory health among women and children. Information on health status, household characteristics and socioeconomic factors was collected using a modified standardised questionnaire. Results: This study demonstrates the significant health impact of housing and socioeconomic characteristics on the burden of respiratory illness among women and children in urban South India. Increased respiratory symptoms were recorded among women and children from low income households, and those who allowed smoking inside. The mean PM2.5 concentration measured in this study was 3.8 mg/m3 which exceeded the World Health Organization (WHO 24 h guideline value of 0.025 mg/m3. Conclusions: This study is the first to our knowledge carried out in urban South India and the findings can be used for future intervention studies.

  15. Indoor Pollution Emissions from Building Materials; Case of Study: Gypsum Boards Indoor Pollution Emissions from Building Materials; Case of Study: Gypsum Boards

    Directory of Open Access Journals (Sweden)

    Silverio Hernández Moreno

    2012-02-01

    common room; for example, a classroom or a workstation. The indoor environmental conditions, such as ventilation, temperature, and humidity, affect chemical emissions from building materials. The technical methodology used, is based on the comparison of conventional materials and alternative materials with similar characteristics and different composition, using similar testing methods, environmental conditions, and instruments and tools. This is a very important report to understand problems related to environmental pollution, specifically of air and its effects indoors, directly on public health, and indirectly on building systems and selection of materials. The tests conclude that alternative materials (with recycled content are better than traditional ones, because they reduce indoor pollution.

  16. Indoor navigation by image recognition

    Science.gov (United States)

    Choi, Io Teng; Leong, Chi Chong; Hong, Ka Wo; Pun, Chi-Man

    2017-07-01

    With the progress of smartphones hardware, it is simple on smartphone using image recognition technique such as face detection. In addition, indoor navigation system development is much slower than outdoor navigation system. Hence, this research proves a usage of image recognition technique for navigation in indoor environment. In this paper, we introduced an indoor navigation application that uses the indoor environment features to locate user's location and a route calculating algorithm to generate an appropriate path for user. The application is implemented on Android smartphone rather than iPhone. Yet, the application design can also be applied on iOS because the design is implemented without using special features only for Android. We found that digital navigation system provides better and clearer location information than paper map. Also, the indoor environment is ideal for Image recognition processing. Hence, the results motivate us to design an indoor navigation system using image recognition.

  17. The carbon footprint of indoor Cannabis production

    International Nuclear Information System (INIS)

    Mills, Evan

    2012-01-01

    The emergent industry of indoor Cannabis production – legal in some jurisdictions and illicit in others – utilizes highly energy intensive processes to control environmental conditions during cultivation. This article estimates the energy consumption for this practice in the United States at 1% of national electricity use, or $6 billion each year. One average kilogram of final product is associated with 4600 kg of carbon dioxide emissions to the atmosphere, or that of 3 million average U.S. cars when aggregated across all national production. The practice of indoor cultivation is driven by criminalization, pursuit of security, pest and disease management, and the desire for greater process control and yields. Energy analysts and policymakers have not previously addressed this use of energy. The unchecked growth of electricity demand in this sector confounds energy forecasts and obscures savings from energy efficiency programs and policies. While criminalization has contributed to the substantial energy intensity, legalization would not change the situation materially without ancillary efforts to manage energy use, provide consumer information via labeling, and other measures. Were product prices to fall as a result of legalization, indoor production using current practices could rapidly become non-viable. - Highlights: ► The emergent industry of indoor Cannabis production utilizes highly energy intensive processes and is highly inefficient. ► In the United States, this represents an annual energy expenditure of $6 billion. ► One kg of final product is associated with emissions of 4600 kg of CO 2 emissions to the atmosphere. ► Aggregate U.S. emissions are equivalent those of 3 million cars. ► Energy analysts and policymakers have not previously addressed this use of energy.

  18. [Impact of air fresheners and deodorizers on the indoor total volatile organic compounds].

    Science.gov (United States)

    Jinno, Hideto; Tanaka-Kagawa, Toshiko; Obama, Tomoko; Miyagawa, Makoto; Yoshikawa, Jun; Komatsu, Kazuhiro; Tokunaga, Hiroshi

    2007-01-01

    Indoor air quality is a growing health concern because of the increased incidence of the building-related illness, such as sick-building syndrome and multiple chemical sensitivity/idiopathic environmental intolerance. In order to effectively reduce the unnecessary chemical exposure in the indoor environment, it would be important to quantitatively compare the emissions from many types of sources. Besides the chemical emissions from the building materials, daily use of household products may contribute at significant levels to the indoor volatile organic compounds (VOCs). In this study, we investigated the emission rate of VOCs and carbonyl compounds for 30 air fresheners and deodorizers by the standard small chamber test method (JIS A 1901). The total VOC (TVOC) emission rates of these household products ranged from the undetectable level (fragrances in the products account for the major part of the TVOC emissions. Based on the emission rates, the impacts on the indoor TVOC were estimated by the simple model with a volume of 17.4 m3 and a ventilation frequency of 0.5 times/h. The mean of the TVOC increment for the indoor air fresheners was 170 microg/m3, accounting for 40% of the current provisional target value, 400 microg/m3. These results suggest that daily use of household products can significantly influence the indoor air quality.

  19. Do new and renovated schools and kindergartens secure sufficiently high indoor environmental quality?

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Hviid, Christian Anker; Skupien, Agata

    2016-01-01

    or less similar as their conventional counterparts as regards measured parameters of indoor environment. Subjective evaluations made by pupils and teachers did not always match the physical measurements. There were also differences in subjective evaluations made by children and by teachers. In conclusion...

  20. Indoor air radon

    International Nuclear Information System (INIS)

    Cothern, C.R.

    1990-01-01

    This review concerns primarily the health effects that result from indoor air exposure to radon gas and its progeny. Radon enters homes mainly from the soil through cracks in the foundation and other holes to the geologic deposits beneath these structures. Once inside the home the gas decays (half-life 3.8 d) and the ionized atoms adsorb to dust particles and are inhaled. These particles lodge in the lung and can cause lung cancer. The introduction to this review gives some background properties of radon and its progeny that are important to understanding this public health problem as well as a discussion of the units used to describe its concentrations. The data describing the health effects of inhaled radon and its progeny come both from epidemiological and animal studies. The estimates of risk from these two data bases are consistent within a factor of two. The epidemiological studies are primarily for hard rock miners, although some data exist for environmental exposures. The most complete studies are those of the US, Canadian, and Czechoslovakian uranium miners. Although all studies have some deficiencies, those of major importance include uranium miners in Saskatchewan, Canada, Swedish iron miners, and Newfoundland fluorspar miners. These six studies provide varying degrees of detail in the form of dose-response curves. Other epidemiological studies that do not provide quantitative dose-response information, but are useful in describing the health effects, include coal, iron ore and tin miners in the UK, iron ore miners in the Grangesburg and Kiruna, Sweden, metal miners in the US, Navajo uranium miners in the US, Norwegian niobian and magnitite miners, South African gold and uranium miners, French uranium miners, zinc-lead miners in Sweden and a variety of small studies of environmental exposure. An analysis of the epidemiological studies reveals a variety of interpretation problem areas.172 references

  1. Influence of interaction of environmental risk factors and sensitization in young asthmatic children.

    Science.gov (United States)

    Lindfors, A; van Hage-Hamsten, M; Rietz, H; Wickman, M; Nordvall, S L

    1999-10-01

    The increasing prevalence of asthma and allergy in many countries demands evaluation of potential risk factors to improve the possibility of prevention. We studied the association between exposure to cat and dog allergen and allergic sensitization in young children with asthma and interactions with potential environmental risk factors. One hundred eighty-nine young children with asthma were evaluated. IgE antibodies to cat and dog were analyzed. Questionnaires were filled in focusing on exposure to cats and dogs, environmental tobacco smoke (ETS), and signs of home dampness as indicated by window pane condensation (WPC) during the first years of life. House dust was analyzed for content of cat (Fel d 1) and dog (Can f 1) allergen. There was a strong association between the degree of reported exposure to cat and dog and the concentration of the respective allergens in floor dust. A dose-response relationship was found between cat exposure, measured as either reported degree of cat exposure or cat allergen levels in dust, and sensitization both to cat and dog. No such relationship was found between exposure and sensitization to dog. WPC increased the risk for sensitization to cat (odds ratio = 2.6, 95% confidence interval 1.2-5.8), whereas ETS strongly tended to do so both to cat and dog. Interaction was found between exposure to ETS, WPC, and high levels of cat allergen (>8 microg/g dust). The presence of all 3 risk factors revealed a multiplicative interaction with a high risk of sensitization to cat (odds ratio = 42.0, 95% confidence interval 3.7-472.8). Keeping cats indoors may be a health hazard for infants and young children at risk for development of asthma, particularly when they live in a damp house and their parents smoke.

  2. Spatial subdivision of complex indoor environments for 3D indoor navigation

    NARCIS (Netherlands)

    Diakite, A.A.; Zlatanova, S.

    2018-01-01

    As we realize that we spend most of our time in increasingly complex indoor environments, applications to assist indoor activities (e.g. guidance) have gained a lot of attention in the recent years. The advances in ubiquitous computing made possible the development of several spatial models

  3. The indoor air we breathe.

    Science.gov (United States)

    Oliver, L C; Shackleton, B W

    1998-01-01

    Increasingly recognized as a potential public health problem since the outbreak of Legionnaire's disease in Philadelphia in 1976, polluted indoor air has been associated with health problems that include asthma, sick building syndrome, multiple chemical sensitivity, and hypersensitivity pneumonitis. Symptoms are often nonspecific and include headache, eye and throat irritation, chest tightness and shortness of breath, and fatigue. Air-borne contaminants include commonly used chemicals, vehicular exhaust, microbial organisms, fibrous glass particles, and dust. Identified causes include defective building design and construction, aging of buildings and their ventilation systems, poor climate control, inattention to building maintenance. A major contributory factor is the explosion in the use of chemicals in building construction and furnishing materials over the past four decades. Organizational issues and psychological variables often contribute to the problem and hinder its resolution. This article describes the health problems related to poor indoor air quality and offers solutions.

  4. Integrated indoor and outdoor exposure assessment framework for fine particulate matter pollution

    DEFF Research Database (Denmark)

    McKone, Thomas E; Hodas, Natasha; Apte, Joshua S.

    2016-01-01

    The 2010 Global Burden of Disease report demonstrates that fine particulate matter (PM2.5) pollution is the major environmental contributor to mortality. Exposures outdoors (ambient) and indoors (household) contribute almost qually to this burden. Unfortunately, the health impacts from exposure t...

  5. Environmental Factors Affecting Preschoolers' Motor Development

    Science.gov (United States)

    Venetsanou, Fotini; Kambas, Antonis

    2010-01-01

    The process of development occurs according to the pattern established by the genetic potential and also by the influence of environmental factors. The aim of the present study was to focus on the main environmental factors affecting motor development. The review of the literature revealed that family features, such as socioeconomic status,…

  6. Graph Model Based Indoor Tracking

    DEFF Research Database (Denmark)

    Jensen, Christian Søndergaard; Lu, Hua; Yang, Bin

    2009-01-01

    The tracking of the locations of moving objects in large indoor spaces is important, as it enables a range of applications related to, e.g., security and indoor navigation and guidance. This paper presents a graph model based approach to indoor tracking that offers a uniform data management...

  7. Cancer risk disparities between hispanic and non-hispanic white populations: the role of exposure to indoor air pollution.

    Science.gov (United States)

    Hun, Diana E; Siegel, Jeffrey A; Morandi, Maria T; Stock, Thomas H; Corsi, Richard L

    2009-12-01

    Hispanics are the fastest growing minority group in the United States; however, minimal information is available on their cancer risks from exposures to hazardous air pollutants (HAPs) and how these risks compare to risks to non-Hispanic whites. We estimated the personal exposure and cancer risk of Hispanic and white adults who participated in the Relationships of Indoor, Outdoor, and Personal Air (RIOPA) study. We evaluated 12 of the sampled volatile organic compounds and carbonyls and identified the HAPs of most concern and their possible sources. Furthermore, we examined sociodemographic factors and building characteristics. Cumulative cancer risks (CCRs) estimated for Hispanics (median = 519 x 10(-6), 90th percentile = 3,968 x 10(-6)) and for whites (median = 443 x 10(-6), 90th percentile = 751 x 10(-6)) were much greater than the U.S. Environmental Protection Agency (EPA) benchmark of 10(-6). Cumulative risks were dominated by formaldehyde and p-dichlorobenzene (p-DCB) and, to a lesser extent, by acetaldehyde, chloroform, and benzene. Exposure to all of these compounds except benzene was primarily due to indoor residential sources. Hispanics had statistically higher CCRs than did whites (p indoors increased in houses with lower ventilation rates. Hispanics appear to be disproportionately affected by certain HAPs from indoor and outdoor sources. Policies that aim to reduce risk from exposure to HAPs for the entire population and population subgroups should consider indoor air pollution.

  8. Indoor and Outdoor Allergies.

    Science.gov (United States)

    Singh, Madhavi; Hays, Amy

    2016-09-01

    In last 30 to 40 years there has been a significant increase in the incidence of allergy. This increase cannot be explained by genetic factors alone. Increasing air pollution and its interaction with biological allergens along with changing lifestyles are contributing factors. Dust mites, molds, and animal allergens contribute to most of the sensitization in the indoor setting. Tree and grass pollens are the leading allergens in the outdoor setting. Worsening air pollution and increasing particulate matter worsen allergy symptoms and associated morbidity. Cross-sensitization of allergens is common. Treatment involves avoidance of allergens, modifying lifestyle, medical treatment, and immunotherapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Variability of radon and thoron equilibrium factors in indoor environment of Garhwal Himalaya

    International Nuclear Information System (INIS)

    Prasad, Mukesh; Rawat, Mukesh; Dangwal, Anoop; Kandari, Tushar; Gusain, G.S.; Mishra, Rosaline; Ramola, R.C.

    2016-01-01

    The measurements of radon, thoron and their progeny concentrations have been carried out in the dwellings of Uttarkashi and Tehri districts of Garhwal Himalaya, India using LR-115 detector based pin-hole dosimeter and DRPS/DTPS techniques. The equilibrium factors for radon, thoron and their progeny were calculated by using the values measured with these techniques. The average values of equilibrium factor between radon and its progeny have been found to be 0.44, 0.39, 0.39 and 0.28 for rainy, autumn, winter and summer seasons, respectively. For thoron and its progeny, the average values of equilibrium factor have been found to be 0.04, 0.04, 0.04 and 0.03 for rainy, autumn, winter and summer seasons, respectively. The equilibrium factor between radon and its progeny has been found to be dependent on the seasonal changes. However, the equilibrium factor for thoron and progeny has been found to be same for rainy, autumn and winter seasons but slightly different for summer season. The annual average equilibrium factors for radon and thoron have been found to vary from 0.23 to 0.80 with an average of 0.42 and from 0.01 to 0.29 with an average of 0.07, respectively. The detailed discussion of the measurement techniques and the explanation for the results obtained is given in the paper. - Highlights: • Equilibrium factors for indoor radon, thoron and their progeny were measured. • Recently developed passive detector techniques were used for measurements. • The values of equilibrium factors are comparable with world's average values. • Equilibrium factor should be measured separately for individual dwelling. • Separate values of equilibrium factors are useful to produce actual radiation dose.

  10. [Association between indoor contamination and respiratory diseases in children living in Temuco and Padre Las Casas, Chile].

    Science.gov (United States)

    Rivas R, Edith; Barrios C, Sara; Dorner P, Anita; Osorio S, Ximena

    2008-06-01

    Indoor air pollution, is the main cause of population exposure to polluting agents. To establish an environmental profile of indoor contamination emission sources in families of children under 5 years that assist to kindergartens in Temuco and Padre Las Casas. To associate respiratory disease episodes in children with indoor contamination. Cross sectional analysis of 355 family groups subjected to questionnaires about indoor contamination and number of respiratory disease episodes. Forty six percent of mothers or caregivers smoked, 37% smoked at home and 93% smoked one to two cigarettes per day. There was a significant association between respiratory diseases in children and drying clothes in the kitchen, using firewood for heating and the presence of humidity in the dwelling. Mothers identified as indoor contaminants the use of braziers in 76% of cases and firewood stoves in 24%. Ninety seven percent considered that these appliances were detrimental for respiratory health. The lack of awareness about indoor contamination among subjects of low socioeconomic status should prompt educational campaigns to modify behaviors in their dwellings.

  11. Genetic diversity of Aspergillus fumigatus in indoor hospital environments.

    Science.gov (United States)

    Araujo, Ricardo; Amorim, António; Gusmão, Leonor

    2010-09-01

    Environmental isolates of Aspergillus fumigatus are less studied than those recovered from clinical sources. In the present study, the genetic diversity among such environmental isolates was assessed, as well as their dispersion ability and the acquisition of new strains in 19 medical units of the same hospital. A. fumigatus isolates were genotyped using a single multiplex PCR-based reaction with eight microsatellite markers and an insertion/deletion polymorphism. A total of 130 unique genotypes were found among a total of 250 A. fumigatus isolates. Genotypic diversity ranged from 0.86 to 1 in samples from hospital rooms, and there was no correlation between these samples and the presence of high-efficiency particulate air filters or any other air filtration system. Four of the six most prevalent A. fumigatus strains were recovered from water samples. The occurrence of microvariation was common among environmental isolates, which affected each of the microsatellite markers. The assessment of the genetic diversity of A. fumigatus is a useful tool for illustrating the presence or absence of specific clonal populations in a clinical setting. A. fumigatus populations were highly dynamic indoors, and new populations were found in just a few months. Due to the high indoor dispersion capability of A. fumigatus, more attention should be given to strains with increased pathogenic potential or reduced susceptibility to anti-fungal drugs.

  12. Morphological Observations and Fatty Acid Composition of Indoor-Cultivated Cordyceps sinensis at a High-Altitude Laboratory on Sejila Mountain, Tibet

    Science.gov (United States)

    Guo, Lian-Xian; Xu, Xiao-Ming; Liang, Fu-Rui; Yuan, Jian-Ping; Peng, Juan; Wu, Chou-Fei; Wang, Jiang-Hai

    2015-01-01

    Cordyceps sinensis, a caterpillar entomopathogenic fungus-host larva complex, is a rare medicinal herb found in the Qinghai-Tibetan Plateau and its surrounding high-altitude areas. The alternation of generations in the life cycle, whatever the fungus or its host insect, requires special growth conditions. However, it is difficult to simulate the growth conditions of C. sinensis, which hinders its artificial cultivation. In this work, the life cycle from the host larva to C. sinensis was observed in an indoor-cultivation laboratory at 4,200 m a.s.l. on Sejila Mountain, Tibet. Comparative examinations between indoor-cultivated and wild C. sinensis demonstrated that the indoor-cultivated C. sinensis preferred to germinate multiple long, slim stromata at diverse positions on dead larvae, including but not limited to their heads. Their fatty acid composition shows a significant difference in the levels of polyunsaturated fatty acids (PUFAs). In indoor-cultivated C. sinensis, PUFAs constituted 24.59% and 49.43%, respectively, of neutral and polar lipids; meanwhile, in wild C. sinensis, PUFAs represented 34.34% and 61.25% of neutral and polar lipids, respectively. These observations and fatty acid data suggest that environmental factors, particularly temperature, soil pressure and light intensity, strongly affect the growth of C. sinensis. Our new findings may provide important information for improving techniques for the large-scale artificial cultivation of C. sinensis. PMID:25938484

  13. Radon concentration in indoor occupational environments in Aomori Prefecture, Japan

    International Nuclear Information System (INIS)

    Iyogi, T.; Ueda, S.; Hisamatsu, S.; Kondo, K.; Sakurai, N.; Inaba, J.

    2003-01-01

    The 222 Rn concentrations in indoor workplaces were measured in Aomori Prefecture, Japan, and the results are reported here. This survey was part of a program to measure background natural radiation dose rate in the prefecture where the first Japanese nuclear fuel cycling facilities are now under construction. The survey of the 222 Rn concentrations in indoor workplaces was carried out at 107 locations from 1996 to 1998. The 222 Rn concentrations were measured for approximately one year at each site with passive Rn detectors, which used a polycarbonate film for counting α-rays and could separate concentrations of 222 Rn from 220 Rn. Weeklong measurements of 222 Rn concentration and working level were carried out with active detectors to get the ratio of 222 Rn concentration during working hours to non-working hours as well as equilibrium factors in selected locations. Diurnal variation of 222 Rn concentration depended on building structure, air-conditioning, time of day and day of the week (week days or weekend). The 222 Rn concentration during working hours was generally lower than that in non-working hours. Although the annual average 222 Rn concentration in indoor occupational environments was higher than that in dwellings, radiation dose for Aomori Prefecture residents from Rn in the former was 14% of the total indoor dose by Rn because of the lower concentration in working hours and lower occupancy factor

  14. California's program: Indoor air problems aren't amenable to regulation

    International Nuclear Information System (INIS)

    Wesolowski, J.

    1993-01-01

    In 1982, California's legislature established an Indoor Air Quality Program (CIAQP) in the Department of Health Services to carry out research on the nature and extent of the indoor air problem (excluding industrial worksites), to find appropriate mitigation measures, and to promote and coordinate the efforts of other state agencies. Since indoor air problems usually are not amenable to regulatory solutions, regulatory authority was not included in the mandate. The program conducts research into a wide range of contaminants--radon, asbestos, formaldehyde, carbon monoxide, volatile organic compounds, environmental tobacco smoke (ETS), as well as into biological aerosols that cause such diseases as Legionnaires disease, tuberculosis, allergies, and asthma. Studies are also carried out to better understand the Sick Building Syndrome. The research includes field surveys to determine the exposure of the population to specific contaminants and experiments in the laboratory to develop protocols for reducing exposures. The research emphasizes measurement of exposure--concentration multiplied by the time a person is exposed--as opposed to measurement of concentration only

  15. An assessment of indoor radon exposure in Ireland

    International Nuclear Information System (INIS)

    McLaughlin, J.P.

    1987-01-01

    The results of measurements of indoor radon in over 700 dwellings chosen at ''random'' throughout the Republic of Ireland are presented. The median value of radon in these dwellings was found to be 37 Bq/m 3 (1 pCi/1). The distribution of indoor radon concentration appears to be approximately log-normal with about 2% of the dwellings surveyed having concentrations greater than 400 Bq/m 3 . High radon values were generally found to be more common in western and southern regions of the country than in the more densely populated eastern seabord. Using dose conversion factors in keeping with recent developments in lung dosimetry the median effective dose equivalent to occupants arising from the inhalation of radon daughters in the dwellings surveyed is estimated to be about 1.8 mSv per year. On the same basis for dwellings with indoor radon above 400 Bq/m 3 the continuous effective dose equivalent is estimated to be in excess of 20 mSv per year

  16. Comparative Indoor and Outdoor Degradation of Organic Photovoltaic Cells via Inter-laboratory Collaboration

    DEFF Research Database (Denmark)

    Owens, Charles; Ferguson, Gretta Mae; Hermenau, Martin

    2016-01-01

    We report on the degradation of organic photovoltaic (OPV) cells in both indoor and outdoor environments. Eight different research groups contributed state of the art OPV cells to be studied at Pomona College. Power conversion efficiency and fill factor were determined from IV curves collected...... at regular intervals over six to eight months. Similarly prepared devices were measured indoors, outdoors, and after dark storage. Device architectures are compared. Cells kept indoors performed better than outdoors due to the lack of temperature and humidity extremes. Encapsulated cells performed better due...

  17. Lead Poisoning at an Indoor Firing Range.

    Science.gov (United States)

    Kang, Kyung Wook; Park, Won Ju

    2017-10-01

    In March 2014, a 39-year-old Korean male presented with a 6-month history of various nonspecific symptoms including dizziness, fatigue, asthenia, irritability, elevated blood pressure, palpitation, eyestrain, and tinnitus. His occupational history revealed that he had been working as an indoor firing range manager for 13 months; therefore, he was subjected to a blood lead level (BLL) test. The test results showed a BLL of 64 μg/dL; hence, he was diagnosed with lead poisoning and immediately withdrawn from work. As evident from the workplace environmental monitoring, the level of lead exposure in the air exceeded its limit (0.015-0.387 mg/m³). He received chelation treatment with calcium-disodium ethylenediaminetetraacetic acid (1 g/day) for 5 days without any adverse effects. In the follow-up results after 2 months, the BLL had decreased to 9.7 μg/dL and the symptoms resolved. This report represents the first occupational case of lead poisoning in firing ranges in Korea, and this necessitates institutional management to prevent the recurrence of poisoning through this route. Workplace environmental monitoring should be implemented for indoor firing ranges, and the workers should undergo regularly scheduled special health examinations. In clinical practice, it is essential to question the patient about his occupational history. © 2017 The Korean Academy of Medical Sciences.

  18. Indoor metallic pollution related to mining activity in the Bolivian Altiplano

    International Nuclear Information System (INIS)

    Fonturbel, Francisco E.; Barbieri, Enio; Herbas, Cristian; Barbieri, Flavia L.; Gardon, Jacques

    2011-01-01

    The environmental pollution associated with mining and metallurgical activities reaches its greatest extent in several Andean cities and villages. Many locations in this area have accumulated through centuries a large amount of mining wastes, often disregarding the magnitude of this situation. However, in these naturally mineralized regions, there is little information available stating the exact role of mining and metallurgical industries in urban pollution. In this study, we demonstrated that the various metallic elements present in indoor dust (As, Cd, Cu, Pb, Sb, Sn, Zn) had a common origin and this contamination was increased by the proximity to the mines. Lead dust concentration was found at concerning levels for public health. In addition, wrong behaviors such as carrying mining workwear home contributed to this indoor dust pollution. Consequently, the constant exposure of the population could represent a potential health hazard for vulnerable groups, especially children. - Highlights: → We measured polymetallic pollution in household indoor dust from a mining town. → Toxic elements (Pb, As, Cd, Sb) in dust are correlated, suggesting a common origin. → The most polluted houses are within a 1 km radius around the mining center. → Carrying mining workwear home increases indoor pollution. → Lead concentrations in dust represent a serious concern for Public Health (600 μg/g). - In a typical Andean mining city, the urban indoor pollution with toxic metallic elements is directly related to the closeness of the mining activities.

  19. Indoor metallic pollution related to mining activity in the Bolivian Altiplano

    Energy Technology Data Exchange (ETDEWEB)

    Fonturbel, Francisco E., E-mail: fonturbel@ug.uchile.cl [Departamento de Ciencias Ecologicas, Facultad de Ciencias, Universidad de Chile, Santiago (Chile); Barbieri, Enio [IRD-HSM (Institut de Recherche pour le Developpement), La Paz (Bolivia, Plurinational State of); Herbas, Cristian [Universidad Mayor de San Andres, IGEMA Institute (Instituto de Investigaciones Geologicas y del Medio Ambiente), La Paz (Bolivia, Plurinational State of); Barbieri, Flavia L.; Gardon, Jacques [IRD-HSM (Institut de Recherche pour le Developpement), La Paz (Bolivia, Plurinational State of); Universidad Mayor de San Andres, SELADIS Institute (Instituto de Servicios de Laboratorio para el Diagnostico e Investigacion en Salud), La Paz (Bolivia, Plurinational State of)

    2011-10-15

    The environmental pollution associated with mining and metallurgical activities reaches its greatest extent in several Andean cities and villages. Many locations in this area have accumulated through centuries a large amount of mining wastes, often disregarding the magnitude of this situation. However, in these naturally mineralized regions, there is little information available stating the exact role of mining and metallurgical industries in urban pollution. In this study, we demonstrated that the various metallic elements present in indoor dust (As, Cd, Cu, Pb, Sb, Sn, Zn) had a common origin and this contamination was increased by the proximity to the mines. Lead dust concentration was found at concerning levels for public health. In addition, wrong behaviors such as carrying mining workwear home contributed to this indoor dust pollution. Consequently, the constant exposure of the population could represent a potential health hazard for vulnerable groups, especially children. - Highlights: > We measured polymetallic pollution in household indoor dust from a mining town. > Toxic elements (Pb, As, Cd, Sb) in dust are correlated, suggesting a common origin. > The most polluted houses are within a 1 km radius around the mining center. > Carrying mining workwear home increases indoor pollution. > Lead concentrations in dust represent a serious concern for Public Health (600 {mu}g/g). - In a typical Andean mining city, the urban indoor pollution with toxic metallic elements is directly related to the closeness of the mining activities.

  20. Study on Data Clustering and Intelligent Decision Algorithm of Indoor Localization

    Science.gov (United States)

    Liu, Zexi

    2018-01-01

    Indoor positioning technology enables the human beings to have the ability of positional perception in architectural space, and there is a shortage of single network coverage and the problem of location data redundancy. So this article puts forward the indoor positioning data clustering algorithm and intelligent decision-making research, design the basic ideas of multi-source indoor positioning technology, analyzes the fingerprint localization algorithm based on distance measurement, position and orientation of inertial device integration. By optimizing the clustering processing of massive indoor location data, the data normalization pretreatment, multi-dimensional controllable clustering center and multi-factor clustering are realized, and the redundancy of locating data is reduced. In addition, the path is proposed based on neural network inference and decision, design the sparse data input layer, the dynamic feedback hidden layer and output layer, low dimensional results improve the intelligent navigation path planning.

  1. Measuring the Environmental Burden of Disease in South Korea: A Population-Based Study

    Directory of Open Access Journals (Sweden)

    Seok-Jun Yoon

    2015-07-01

    Full Text Available Background: This study attempted to measure the environmental burden of disease by examining mortality and disability rates in South Korea, permitting international comparisons. Methods: Disability-adjusted life years (DALY was used to analyze data from public records. Years of life lost (YLL and years lost to disability (YLD were measured in terms of incidence rate and number of deaths. Attributable risks were based on those for WHO Western Pacific Regions. For air pollution, attributable risk was calculated using local PM10 levels and relative risk. Results: The total Korean environmental burden of disease was 17.98 per 1000 persons and the most serious risk factor was air pollution, at 6.89per1000 persons. Occupation was the second highest contributing factor, at 3.29 per 1000 persons, followed by indoor air pollution at 2.91 per 1000 persons. The DALY of air-pollution (indoor and outdoor was 9.80 per 1000 persons, accounting for more than half of the total environmental burden of disease. The burden of chronic obstructive pulmonary disease, lung cancer, and asthma were 4.07, 3.16, and 1.96 per 1000 persons, respectively. Conclusions: Respiratory illnesses comprised most of the disease burden, the majority of which was linked to air pollution. The present results are important as they could be used to make evidence-based decisions regarding the management of diseases and environmental-risk factors.

  2. Editorial input for the right price: tobacco industry support for a sheet metal indoor air quality manual.

    Science.gov (United States)

    Campbell, Richard; Balbach, Edith

    2013-01-01

    Following legal action in the 1990s, internal tobacco industry documents became public, allowing unprecedented insight into the industry's relationships with outside organizations. During the 1980s and 1990s, the National Energy Management Institute (NEMI), established by the Sheet Metal Workers International Association and the Sheet Metal and Air Conditioning Contractors' National Association, (SMACNA) received tobacco industry funding to establish an indoor air quality services program. But the arrangement also required NEMI to serve as an advocate for industry efforts to defeat indoor smoking bans by arguing that ventilation was a more appropriate solution to environmental tobacco smoke. Drawing on tobacco industry documents, this paper describes a striking example of the ethical compromises that accompanied NEMI's collaboration with the tobacco industry, highlighting the solicitation of tobacco industry financial support for a SMACNA indoor air quality manual in exchange for sanitizing references to the health impact of environmental tobacco smoke prior to publication.

  3. Effectiveness of Indoor Plant to Reduce CO2 in Indoor Environment

    Directory of Open Access Journals (Sweden)

    Suhaimi Mohd Mahathir

    2017-01-01

    Full Text Available Modern country strongly emphasizes on indoor air quality (IAQ because it can effect on human health and productivity. Numerous efforts were performed to make sure that sustainability of IAQ is guaranteed. In the last 4th decade, researchers discover that indoor plants have abilities to reduce indoor air pollution. Generally, plants, carbon dioxide (CO2, light, and temperature involve in the photosynthesis process. This paper intends to study the effectiveness of seven indoor plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium to reduce CO2 with different light level. This study was conducted in one cubic meter of chamber, and each plant was put into the chamber individually with CO2 concentration in the chamber is set at 1000±50ppm, and light intensities is set at 300 and 700 lux, while temperature were fixed at 25±1°C. Based on the results, only the Spider Plant was not able to absorb CO2 during the test at 300 lux of light intensity. Meanwhile, Prayer Plant performed well when tested at 300 or 700 lux of light intensity compare to other investigates plants. This study can conclude that light intensity play an important role for the plant to absorb CO2 effectively. All the indoor plants absorbed more CO2, when the light intensity is increased.

  4. Daily time spent indoors in German homes--baseline data for the assessment of indoor exposure of German occupants.

    Science.gov (United States)

    Brasche, Sabine; Bischof, Wolfgang

    2005-01-01

    Comprehensive time-activity studies, for use as a basis for estimates of personal exposure, are not readily available in Germany. This analysis of time spent indoors at home is based on data from "Dampness and mould in homes" (2000/ 2001)--a study of about 12,000 persons living in 5530 randomly selected apartments and houses in Germany. The results show the mean times per day people in Germany spend in their homes, classified by gender, age group, building location, city size, region, building type, owner-occupier status, number of people at home, smoking and ventilation habits, moisture emission and ill health factors such as asthma, allergy and number of acute respiratory infections per year. The overall mean time spent at home, 15.7 h per, is in accordance with results from US-American (15.6 h/day) and Canadian (15.8 h/day) human activity surveys carried out in the nineties, as well as being consistent with the German Environmental Survey (1990/92) and a small German study in 1987.

  5. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull 2007; 6(3.000: 221-226

  6. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull. 2007; 6(3: 221-226

  7. Indoor radon concentration and outdoor/indoor pressure difference correlation

    International Nuclear Information System (INIS)

    Cechak, T.; Fronka, A.; Moucka, L.

    2004-01-01

    In the current approach to the radon issue, the radon risk for people living in a building is estimated based on the average indoor radon concentration. Short-term measurements as usually applied fail to reflect the wide range of radon variations arising from ventilation, radon supply and, in particular, human activities in the building. For this reason, efforts are made to find a new approach to the assessment of the quality of a building as a radon barrier, independent of the weather conditions and residential habits. A simple model of radon volume activity entering the building at a constant rate and simultaneously ventilated at a constant rate is applicable to this task. The rate of radon ingress can be regarded as a parameter making it possible to quantify the leakage of structures provided the barrier against the radon in a soil gas. The ventilation rate, on the other hand, characterizes the leakage of the whole building envelope at a given outdoor/indoor pressure difference. A unique measuring technique called the blower door exists whereby a defined pressure difference between the indoor and outdoor atmosphere can be established. Under such conditions both the ventilation rate and the rate of radon ingress can be measured and expressed as a function of the pressure difference. An analysis of the model of a room with a constant ventilation and constant radon supply is presented and the relationship between radon supply and ventilation rate can be assumed. Some experimental results show how the model can be utilized. The real indoor-outdoor air pressure differences, the indoor-soil air pressure differences, and some effects of different ventilation regimes are given. Other experiments, which have been done by using the blower door method, illustrate the possible effects and some restrictions for a routine application are discussed

  8. Impact of Presence of Children on Indoor Tobacco Restrictions in Households of Urban and Rural Adult Tobacco Users.

    Science.gov (United States)

    Kopp, Benjamin T; Hinton, Alice; Lu, Rong; Cooper, Sarah; Nagaraja, Haikady; Wewers, Mary Ellen

    2018-04-10

    Secondhand smoke exposure in children is changing as a result of new public policy and electronic nicotine products (e-cigarettes). We examined factors related to self-imposed indoor household tobacco restrictions, with emphasis on children in the household and associations with combustible and noncombustible product use. A cross-sectional survey of urban and rural Ohio adult tobacco users classified participants as exclusive combustible users, smokeless tobacco (SLT) users, e-cigarette users, or dual users. They were further stratified according to combustible or noncombustible product use and the presence of indoor tobacco use restrictions. Multiple logistic regression determined factors associated with indoor tobacco restrictions. A total of 1210 tobacco users participated, including 25.7% with children living in the home. Half allowed combustible and two thirds allowed noncombustible tobacco use indoors. Urban location (odds ratio [OR] = 1.58), younger age (OR = 0.88 per 5 year), male sex (OR = 1.40), college education (OR = 1.40), household income of more than $15,000 (OR = 1.78), and being married (OR = 2.43) were associated with a higher likelihood of banning combustible products indoors. SLT (OR = 8.12) and e-cigarette (OR = 5.85) users were more likely to have indoor bans compared to combustible users. Children in the household (OR = 1.89), older age (OR = 1.12 per 5 years), and nonwhite race (OR = 1.68) were associated with a higher likelihood of banning noncombustible products indoors. Combustible (OR = 4.54) and e-cigarette (OR = 3.04) users were more likely than SLT users to have indoor bans. Indoor restrictions on tobacco use remain infrequent in homes with children and are associated with user type and socioeconomic factors. Public policy should target modifiable risk factors for in-home secondhand smoke exposure. Copyright © 2018 Academic Pediatric Association. Published by Elsevier Inc. All

  9. Observations on persistent organic pollutants in indoor and outdoor air using passive polyurethane foam samplers

    Science.gov (United States)

    Bohlin, Pernilla; Jones, Kevin C.; Tovalin, Horacio; Strandberg, Bo

    Air quality data of persistent organic pollutants (POPs) indoors and outdoors are sparse or lacking in several parts of the world, often hampered by the cost and inconvenience of active sampling techniques. Cheap and easy passive air sampling techniques are therefore helpful for reconnaissance surveys. As a part of the Megacity Initiative: Local and Global Research Observations (MILAGRO) project in Mexico City Metropolitan Area in 2006, a range of POPs (polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), and polybrominated diphenyl ethers (PBDEs)) were analyzed in polyurethane foam (PUF) disks used as passive samplers in indoor and outdoor air. Results were compared to those from samplers deployed simultaneously in Gothenburg (Sweden) and Lancaster (United Kingdom). Using sampling rates suggested in the literature, the sums of 13 PAHs in the different sites were estimated to be 6.1-180 ng m -3, with phenanthrene as the predominant compound. Indoor PAH levels tended to be higher in Gothenburg and outdoor levels higher in Mexico City. The sum of PCBs ranged 59-2100 ng m -3, and seemed to be highest indoors in Gothenburg and Lancaster. PBDE levels (sum of seven) ranged 0.68-620 ng m -3, with the highest levels found in some indoor locations. OCPs (i.e. DDTs, HCHs, and chlordanes) were widely dispersed both outdoors and indoors at all three studied areas. In Gothenburg all POPs tended to be higher indoors than outdoors, while indoor and outdoor levels in Mexico City were similar. This could be due to the influence of indoor and outdoor sources, air exchange rates, and lifestyle factors. The study demonstrates how passive samplers can provide quick and cheap reconnaissance data simultaneously at many locations which can shed light on sources and other factors influencing POP levels in air, especially for the gaseous fractions.

  10. Indoor Air Quality in Schools (IAQ): The Importance of Monitoring Carbon Dioxide Levels.

    Science.gov (United States)

    Sundersingh, David; Bearg, David W.

    This article highlights indoor air quality and exposure to pollutants at school. Typical air pollutants within schools include environmental tobacco smoke, formaldehyde, volatile organic compounds, nitrogen oxides, carbon monoxide, carbon dioxide, allergens, pathogens, radon, pesticides, lead, and dust. Inadequate ventilation, inefficient…

  11. Prevalence of and risk factors for subjective symptoms in urban preschool children without a cause identified by the guardian.

    Science.gov (United States)

    Wang, Bing-Ling; Li, Xi-Ling; Xu, Xiao-Bo; Sun, Yong-Gang; Zhang, Qi

    2012-07-01

    The aim of this study was to explore the prevalence of and the risk factors for subjective symptoms without an identified cause by the guardian (SSWICG) in urban preschool children. A questionnaire was used to collect information from 661 urban preschool children. The subjective symptoms were cited from the MM075NA Indoor Environment Quality Investigation Questionnaire. Information about living conditions, kindergarten and outdoor environments was collected, as well as health information from each child. The prevalence of SSWICG reached 31%, among which the prevalence of general symptoms in the central nervous system (CNS) reached 54.6%. Univariate analysis showed that the materials that made indoor furniture, walls and doors, indoor biological factors, outdoor pollution sources near the house and traffic pollution were associated with SSWICG and mucosal, dermal and general symptoms in the CNS subgroups. Multivariate analysis also showed that furniture materials, traffic pollution, kindergarten environment quality and allergies were associated. The prevalence of SSWICG was relatively high. Possible risk factors include indoor furnishing materials, allergy, traffic pollution and kindergarten environmental pollution.

  12. The transmission characteristics of indoor particles under different ventilation conditions

    Directory of Open Access Journals (Sweden)

    Lv Yang

    2017-01-01

    Full Text Available In modern society, ventilation is an important method for removing indoor particles. This study applies the parameter of attenuation index to analyze the effect of the removal of indoor particles in the two typical ventilation strategies called ceiling exhaust and slit exhaust strategy. Experiment was conducted in a chamber and riboflavin particles were used as the indoor particles source, instantaneous microbial detection (IMD used to measure the particulate concentration. Conclusions can be found that air exchange rate is an important factor affecting the indoor particle concentration distribution. In the process of indoor free settling(air exchange rate is 0 h-1, the deposition rate were 0.086 h-1, 0.122 h-1, 0.173 h-1 for the particles of 0.5–1.0 μm, 1.0–3.0μm and 3.0–5.0 μm. When the air exchange rate increased to 2.5 h-1, the differences in the attenuation index is significant. There was also a significant linear relationship between air exchange rate and attenuation index. Furthermore, the effect of the slit exhaust strategy on the removal of coarse particles is more remarkable as the increasing air exchange rate.

  13. CONTROL OF INDOOR ENVIRONMENTS VIA THE REGULATION OF BUILDING ENVELOPES

    Directory of Open Access Journals (Sweden)

    Mitja Košir

    2011-01-01

    Full Text Available The design of comfortable, healthy and stimulating indoor environments in buildings has a direct impact on the users and on energy consumption, as well as on the wider soci-economic environment of society.The indoor environment of buildings is defined with the formulation of the building envelope, which functions as an interface between the internal and external environments and its users. A properly designed, flexible and adequately controlled building envelope is a starting point in the formulation of a high-quality indoor environment. The systematic treatment of the indoor environment and building envelope from a user’s point of view represents an engineering approach that enables the holistic treatment of buildings, as well as integrated components and systems. The presented division of indoor environment in terms of visual, thermal, olfactory, acoustic and ergonomic sub-environments enables the classification and selection of crucial factors influencing design. This selection and classification can be implemented in the design, as well as in control applications of the building envelope. The implementation of the approach described is demonstrated with an example of an automated control system for the internal environment of an office in the building of the Faculty of Civil and Geodetic Engineering.

  14. Factors influencing indoor PM2.5 concentration in rural houses of northern China

    Science.gov (United States)

    Zhang, Xueyan; Chen, Bin

    2018-02-01

    In traditional houses in rural areas of Northern China, most traditional heating systems, heated by mini-stove in the kitchen, usually take agricultural residues as fuels resources. Besides, burning cave under the ground-floor of a rural house is also widely used. The higher PM2.5 concentration is crisis for human health. In this study, PM2.5 concentration, temperature, relative humidity inside and outside the houses have been measured, moreover the factors impact on I/O rate coefficient has been discussed. The results show that the I/O rate coefficient in the evening is 2.5 times greater than the I/O rate coefficient in the daytime. I/O rate coefficient of PM2.5 concentration is positive related to air temperature difference between indoor and outdoor. In addition, the impact of outdoor wind speed and predominant wind direction on the PM2.5 emission has been studied.

  15. Indoor Environmental Contaminants in Schools

    Science.gov (United States)

    A wide range of environmental contaminants can affect the health and safety of a school environment. This page covers the basics on issues your school may face, including asbestos, chemicals, formaldehyde, lead, mercury, PCBs and radon.

  16. Indoor air pollution and cognitive function among older Mexican adults.

    Science.gov (United States)

    Saenz, Joseph L; Wong, Rebeca; Ailshire, Jennifer A

    2018-01-01

    A growing body of research suggests exposure to high levels of outdoor air pollution may negatively affect cognitive functioning in older adults, but less is known about the link between indoor sources of air pollution and cognitive functioning. We examine the association between exposure to indoor air pollution and cognitive function among older adults in Mexico, a developing country where combustion of biomass for domestic energy remains common. Data come from the 2012 Wave of the Mexican Health and Aging Study. The analytic sample consists of 13 023 Mexican adults over age 50. Indoor air pollution is assessed by the reported use of wood or coal as the household's primary cooking fuel. Cognitive function is measured with assessments of verbal learning, verbal recall, attention, orientation and verbal fluency. Ordinary least squares regression is used to examine cross-sectional differences in cognitive function according to indoor air pollution exposure while accounting for demographic, household, health and economic characteristics. Approximately 16% of the sample reported using wood or coal as their primary cooking fuel, but this was far more common among those residing in the most rural areas (53%). Exposure to indoor air pollution was associated with poorer cognitive performance across all assessments, with the exception of verbal recall, even in fully adjusted models. Indoor air pollution may be an important factor for the cognitive health of older Mexican adults. Public health efforts should continue to develop interventions to reduce exposure to indoor air pollution in rural Mexico. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Reconstruction of national distribution of indoor radon concentration in Russia using results of regional indoor radon measurement programs

    International Nuclear Information System (INIS)

    Yarmoshenko, I.; Malinovsky, G.; Vasilyev, A.; Zhukovsky, M.

    2015-01-01

    The aim of the paper is a reconstruction of the national distribution and estimation of the arithmetic average indoor radon concentration in Russia using the data of official annual 4-DOZ reports. Annual 4-DOZ reports summarize results of radiation measurements in 83 regions of Russian Federation. Information on more than 400 000 indoor radon measurements includes the average indoor radon isotopes equilibrium equivalent concentration (EEC) and number of measurements by regions and by three main types of houses: wooden, one-storey non-wooden, and multi-storey non-wooden houses. To reconstruct the national distribution, all-Russian model sample was generated by integration of sub-samples created using the results of each annual regional program of indoor radon measurements in each type of buildings. According to indoor radon concentration distribution reconstruction, all-Russian average indoor radon concentration is 48 Bq/m"3. Average indoor radon concentration by region ranges from 12 to 207 Bq/m"3. The 95-th percentile of the distribution is reached at indoor radon concentration 160 Bq/m"3. - Highlights: • Reconstruction of indoor radon concentration distribution in Russia was carried out. • Data of official annual 4-DOZ reports were used. • All-Russian average indoor radon concentration is 48 Bq/m"3. • The 95-th percentile is 160 Bq/m"3.

  18. Human response to combined indoor environment exposures

    DEFF Research Database (Denmark)

    Toftum, Jørn

    2002-01-01

    Most thermal comfort standards and guidelines presume sedentary, light activity and a neutral overall thermal sensation when predicting local thermal discomfort. In addition, current standards specify criteria for separate aspects of the indoor environment, e.g. thermal climate, air quality...... or noise, with only little consideration of possible interactions between the different types of exposure. The studies summarized in this article found a clear impact of activity and overall thermal sensation on human sensitivity to air movement, whereas no interaction effects of exposure to several local...... thermal discomfort factors were observed. Limited evidence was found of significant interactions between different aspects of the indoor environment. Only for the effect of air temperature and air humidity on sensory air quality were well-estabished relationships available....

  19. Indoor Environmental Risk Factors for Occupant Symptoms in 100U.S. Office Buildings: Summary of Three Analyses from the EPA BASEStudy

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Lei-Gomez, Q.; Cozen, M.; Brightman, H.S.; Apte,M.; Erdmann, C.A.; Brunner, G.; Girman, J.R.

    2006-02-01

    This paper summarizes three analyses of data on building-related environmental factors and occupant symptoms collected from 100 representative large U.S. office buildings. Using multivariate logistic regression models, we found increased occupant symptoms associated with a number of building-related factors, including lower ventilation rates even at the current guideline levels, lack of scheduled cleaning for air-conditioning drain pans and cooling coils, poor condition of cooling coils, poorly maintained humidification systems, and lower outdoor air intake height. Some expected relationships were not found, and several findings were opposite of expected. Although requiring replication, these findings suggest preventive actions to reduce occupant symptoms in office buildings.

  20. Slovak Republic, indoor measurements

    International Nuclear Information System (INIS)

    Vicanova, M.; Daniel, S.

    2006-01-01

    In this report the annual average effective doses from indoor radon exposure were calculated for each district of Slovakia. The population-weighted arithmetic mean of indoor radon concentration was calculated for every district considering different types of houses.

  1. Knowledge, Internal, and Environmental Factors on Environmental Care Behaviour among Aboriginal Students in Malaysia

    Science.gov (United States)

    Rahman, Norshariani Abd

    2016-01-01

    This study determined the contribution of predictor factors (i.e. knowledge about the environment as well as internal and environmental factors) on environmental care behaviour among aboriginal students. The knowledge about the environment that was investigated in this research includes environmental knowledge and environmental action knowledge.…

  2. Participant evaluation results for two indoor air quality studies

    International Nuclear Information System (INIS)

    Hawthorne, A.R.; Dudney, C.S.; Cohen, M.A.; Spengler, J.D.

    1987-01-01

    After two surveys for indoor air pollutants (radon and other chemicals) the homeowners were surveyed for their reactions. The results of these participant evaluation surveys, assuming that the participants that responded to the survey were representative, indicate that homeowners will accept a significant level of monitoring activity as part of an indoor air quality field study. Those participants completing surveys overwhelmingly enjoyed being in the studies and would do it again. We believe that the emphasis placed on positive homeowner interactions and efforts made to inform participants throughout our studies were positive factors in this result. There was no substantial differences noted in the responses between the 70-house study, which included a homeowner compensation payment of $100, and the 300-house study, which did not include a compensation payment. These results provide encouragement to conduct future complex, multipollutant indoor air quality studies when they are scientifically sound and cost effective

  3. State Indoor Tanning Laws and Prevalence of Indoor Tanning Among US High School Students, 2009-2015.

    Science.gov (United States)

    Qin, Jin; Holman, Dawn M; Jones, Sherry Everett; Berkowitz, Zahava; Guy, Gery P

    2018-07-01

    To examine the association between state indoor tanning laws and indoor tanning behavior using nationally representative samples of US high school students younger than 18 years. We combined data from the 2009, 2011, 2013, and 2015 national Youth Risk Behavior Surveys (n = 41 313) to analyze the association between 2 types of state indoor tanning laws (age restriction and parental permission) and the prevalence of indoor tanning during the 12 months before the survey, adjusting for age, race/ethnicity, and survey year, and stratified by gender. Age restriction laws were associated with a 47% (P tanning prevalence among female high school students. Parental permission laws were not found to be associated with indoor tanning prevalence among either female or male high school students. Age restriction laws could contribute to less indoor tanning, particularly among female high school students. Such reductions may reduce the health and economic burden of skin cancer.

  4. Workshop on indoor air quality research needs

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    Workshop participants report on indoor air quality research needs including the monitoring of indoor air quality, report of the instrumentation subgroup of indoor air quality, health effects, and the report of the control technology session. Risk analysis studies addressing indoor environments were also summarized. (DLS)

  5. Workshop on indoor air quality research needs

    International Nuclear Information System (INIS)

    1980-01-01

    Workshop participants report on indoor air quality research needs including the monitoring of indoor air quality, report of the instrumentation subgroup of indoor air quality, health effects, and the report of the control technology session. Risk analysis studies addressing indoor environments were also summarized

  6. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  7. Accurate estimation of indoor travel times

    DEFF Research Database (Denmark)

    Prentow, Thor Siiger; Blunck, Henrik; Stisen, Allan

    2014-01-01

    The ability to accurately estimate indoor travel times is crucial for enabling improvements within application areas such as indoor navigation, logistics for mobile workers, and facility management. In this paper, we study the challenges inherent in indoor travel time estimation, and we propose...... the InTraTime method for accurately estimating indoor travel times via mining of historical and real-time indoor position traces. The method learns during operation both travel routes, travel times and their respective likelihood---both for routes traveled as well as for sub-routes thereof. InTraTime...... allows to specify temporal and other query parameters, such as time-of-day, day-of-week or the identity of the traveling individual. As input the method is designed to take generic position traces and is thus interoperable with a variety of indoor positioning systems. The method's advantages include...

  8. Indoor ionizing radiation

    International Nuclear Information System (INIS)

    Ericson, S.O.; Lindvall, T.; Maansson, L-G.

    1986-01-01

    Radiation in indoor air is discussed in the perspective of the effective dose equivalents from other sources of radiation. Estimates of effective doses equivalents from indoor radon and its contribution to lung cancer incidence are reviewed. Swedish experiences with cost effective remedial actions are presented. The authors present optimal strategies for screening measurements and remedial actions in cost-benefit perspective. (author.)

  9. Indoor air quality in Brazilian universities.

    Science.gov (United States)

    Jurado, Sonia R; Bankoff, Antônia D P; Sanchez, Andrea

    2014-07-11

    This study evaluated the indoor air quality in Brazilian universities by comparing thirty air-conditioned (AC) (n = 15) and naturally ventilated (NV) (n = 15) classrooms. The parameters of interest were indoor carbon dioxide (CO2), temperature, relative humidity (RH), wind speed, viable mold, and airborne dust levels. The NV rooms had larger concentration of mold than the AC rooms (1001.30 ± 125.16 and 367.00 ± 88.13 cfu/m3, respectively). The average indoor airborne dust concentration exceeded the Brazilian standards (indoor air quality in Brazilian university classrooms affects the health of students. Therefore, indoor air pollution needs to be considered as an important public health problem.

  10. Indoor air pollution in slum neighbourhoods of Addis Ababa, Ethiopia

    Science.gov (United States)

    Sanbata, Habtamu; Asfaw, Araya; Kumie, Abera

    2014-06-01

    An estimated 95% of the population of Ethiopia uses traditional biomass fuels, such as wood, dung, charcoal, or crop residues, to meet household energy needs. As a result of the harmful smoke emitted from the combustion of biomass fuels, indoor air pollution is responsible for more than 50,000 deaths annually and causes nearly 5% of the burden of disease in Ethiopia. Very limited research on indoor air pollution and its health impacts exists in Ethiopia. This study was, therefore, undertaken to assess the magnitude of indoor air pollution from household fuel use in Addis Ababa, the capital city of Ethiopia. During January and February, 2012, the concentration of fine particulate matter (PM2.5) in 59 households was measured using the University of California at Berkeley Particle Monitor (UCB PM). The raw data was analysed using Statistical Package of Social Science (SPSS version 20.0) software to determine variance between groups and descriptive statistics. The geometric mean of 24-h indoor PM2.5 concentration is approximately 818 μg m-3 (Standard deviation (SD = 3.61)). The highest 24-h geometric mean of PM2.5 concentration observed were 1134 μg m-3 (SD = 3.36), 637 μg m-3 (SD = 4.44), and 335 μg m-3 (SD = 2.51), respectively, in households using predominantly solid fuel, kerosene, and clean fuel. Although 24-h mean PM2.5 concentration between fuel types differed statistically (P 0.05). The study revealed indoor air pollution is a major environmental and health hazard from home using biomass fuel in Addis Ababa. The use of clean fuels and efficient cooking stoves is recommended.

  11. Characterization of Indoor Air Quality in Different Archives – Possible Implications for Books and Manuscripts.

    Czech Academy of Sciences Publication Activity Database

    Mašková, Ludmila; Smolík, Jiří; Ďurovič, M.

    2017-01-01

    Roč. 120, August 1 (2017), s. 77-84 ISSN 0360-1323 R&D Projects: GA MK DF11P01OVV020 Keywords : indoor environment * gaseous pollution * indoor/outdoor ratio Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 4.053, year: 2016

  12. Indoor radon in houses built on gravel and sand deposits in southern Finland

    Directory of Open Access Journals (Sweden)

    Hutri, K.-L.

    1993-06-01

    Full Text Available Studies by the Finnish Centre for Radiation and Nuclear Safety (STUK have shown that, in Finland, indoor radon concentrations are almost twice as high in houses built on sand or gravel as in houses built on other soil types. The aim of this study was to assess the radon risk on eskers, ice-marginal formations, and other gravel and sand deposits on the basis of factors that can be determined from geological maps. Altogether, 514 houses built on gravel and sand deposits were selected for the study from the indoor radon database of STUK. Several geological parameters were determined. Empirical statistical models were used to assess the significance of factors affecting indoor radon in glaciofluvial deposits and the sand-dominant littoral deposits occurring in association with them. A relationship was found between increased indoor radon concentrations and the location of a house on a steep-sided esker, in the southeastern rapakivi granite area and on the upper slope or top of an esker. The steepness of the slope also increased the radon concentration in houses on steep-sided eskers. The effect of the topographic features is due to subterranean air-flows. As estimated from the very sparse till sampling, the elevated uranium concentration increased the indoor radon concentration only in houses built on littoral deposits around eskers and ice-marginal formations.

  13. 76 FR 213 - National Environmental Policy Act Implementing Procedures

    Science.gov (United States)

    2011-01-03

    ... due to, for example, a threatened violation of applicable environmental, safety, and health... legally enforceable rights, benefits, or responsibilities, substantive or procedural, not otherwise... failed in indoor tests. Whether the explosives or propellants were tested indoors or outdoors, the...

  14. Indoor environment and installations in nursing home; Binnenmilieu en installaties in het verpleeghuis

    Energy Technology Data Exchange (ETDEWEB)

    Van Hoof, J.; Kort, H.S.M.; Duijnstee, M.S.H. [Kenniscentrum Innovatie van Zorgverlening, Faculteit Gezondheidszorg, Hogeschool Utrecht, Utrecht (Netherlands); Hensen, J.L.M.; Rutten, P.G.S. [Unit Building Physics and Systems, Faculteit Bouwkunde, Technische Universiteit Eindhoven, Eindhoven (Netherlands)

    2010-04-15

    The majority of nursing home residents are older adults with dementia. People with dementia may have an altered sensitivity for indoor environmental conditions, which can induce problematic behaviour with burdensome symptoms. This paper provides an overview of the ageing of senses and needs of older adults with dementia in relation to the indoor environment. Results can help designers and building services engineers to create optima[ environmental conditions in nursing homes. [Dutch] De verpleeghuizen in Nederland bieden zorg en verblijf aan ouderen met een intensieve zorgvraag. Het grote aantal installaties dat in deze woonvorm aanwezig is dient zo te worden ontworpen en geinstalleerd dat deze optimaal comfort bieden aan bewoners en zorgprofessionals. Ouderen met dementie vormen de grootste groep bewoners en hebben zeer specifieke behoeften voor het binnenmilieu. Door hiervan uit te gaan bij ontwerp en installatie, ontstaat een verpleeghuis dat ten dienste staat van alle bewoners en overige gebouwgebruikers.

  15. Relationships of Indoor, Outdoor, and Personal Air (RIOPA). Part I. Collection methods and descriptive analyses.

    Science.gov (United States)

    Weisel, Clifford P; Zhang, Junfeng; Turpin, Barbara J; Morandi, Maria T; Colome, Steven; Stock, Thomas H; Spektor, Dalia M; Korn, Leo; Winer, Arthur M; Kwon, Jaymin; Meng, Qing Yu; Zhang, Lin; Harrington, Robert; Liu, Weili; Reff, Adam; Lee, Jong Hoon; Alimokhtari, Shahnaz; Mohan, Kishan; Shendell, Derek; Jones, Jennifer; Farrar, L; Maberti, Slivia; Fan, Tina

    2005-11-01

    This study on the relationships of indoor, outdoor, and personal air (RIOPA) was undertaken to collect data for use in evaluating the contribution of outdoor sources of air toxics and particulate matter (PM) to personal exposure. The study was not designed to obtain a population-based sample, but rather to provide matched indoor, outdoor, and personal concentrations in homes that varied in their proximity to outdoor pollution sources and had a wide range of air exchange rates (AERs). This design allowed examination of relations among indoor, outdoor, and personal concentrations of air toxics and PM across a wide range of environmental conditions; the resulting data set obtained for a wide range of environmental pollutants and AERs can be used to evaluate exposure models. Approximately 100 households with residents who do not smoke participated in each of three cities in distinct locations expected to have different climates and housing characteristics: Elizabeth, New Jersey; Houston, Texas; and Los Angeles County, California. Questionnaires were administered to characterize homes, neighborhoods, and personal activities that might affect exposures. The concentrations of a suite of volatile organic compounds (VOCs) and carbonyl compounds, as well as the fraction of airborne particulate matter with a mass median aerodynamic diameter personal air samples were collected simultaneously. During the same 48-hour period, the AER (exchanges/hr; x hr(-1)) was determined in each home, and carbonyl compounds were measured inside vehicle cabins driven by a subset of the participants. In most of the homes, measurements were made twice, during two different seasons, to obtain a wide distribution of AERs. This report presents in detail the data collection methods, quality control measures, and initial analyses of data distributions and relations among indoor, outdoor, and personal concentrations. The results show that indoor sources dominated personal and indoor air concentrations

  16. Indoor metallic pollution and children exposure in a mining city

    International Nuclear Information System (INIS)

    Barbieri, Enio; Fontúrbel, Francisco E.; Herbas, Cristian; Barbieri, Flavia L.; Gardon, Jacques

    2014-01-01

    Mining industries are known for causing strong environmental contamination. In most developing countries, the management of mining wastes is not adequate, usually contaminating soil, water and air. This situation is a source of concern for human settlements located near mining centers, especially for vulnerable populations such as children. The aim of this study was to assess the correlations of the metallic concentrations between household dust and children hair, comparing these associations in two different contamination contexts: a mining district and a suburban non-mining area. We collected 113 hair samples from children between 7 and 12 years of age in elementary schools in the mining city of Oruro, Bolivia. We collected 97 indoor dust samples from their households, as well as information about the children's behavior. Analyses of hair and dust samples were conducted to measure As, Cd, Pb, Sb, Sn, Cu and Zn contents. In the mining district, there were significant correlations between non-essential metallic elements (As, Cd, Pb, Sb and Sn) in dust and hair, but not for essential elements (Cu and Zn), which remained after adjusting for children habits. Children who played with dirt had higher dust-hair correlations for Pb, Sb, and Cu (P = 0.006; 0.022 and 0.001 respectively) and children who put hands or toys in their mouths had higher dust-hair correlations of Cd (P = 0.011). On the contrary, in the suburban area, no significant correlations were found between metallic elements in dust and children hair and neither children behavior nor gender modified this lack of associations. Our results suggest that, in a context of high metallic contamination, indoor dust becomes an important exposure pathway for children, modulated by their playing behavior. - Highlights: • Mining activities are an important source of environmental pollution. • Mining pollution contaminated also indoor homes, creating a risk to population. • Indoor dust and hair concentrations in As

  17. Internet-Based Indoor Navigation Services

    OpenAIRE

    Zeinalipour-Yazti, Demetrios; Laoudias, Christos; Georgiou, Kyriakos

    2017-01-01

    Smartphone advances are leading to a class of Internet-based Indoor Navigation services. IIN services rely on geolocation databases that store indoor models, comprising floor maps and points of interest, along with wireless, light, and magnetic signals for localizing users. Developing IIN services creates new information management challenges - such as crowdsourcing indoor models, acquiring and fusing big data velocity signals, localization algorithms, and custodians' location privacy. Here, ...

  18. Environmental and lifestyle factors associated with perceived facial age in Chinese women.

    Directory of Open Access Journals (Sweden)

    Andrew E Mayes

    Full Text Available Perceived facial age has been proposed as a biomarker of ageing with 'looking young for one's age' linked to physical and cognitive functioning and to increased survival for Caucasians. We have investigated the environmental and lifestyle factors associated with perceived facial ageing in Chinese women. Facial photographs were collected from 250 Chinese women, aged 25-70 years in Shanghai, China. Perceived facial age was determined and related to chronological age for each participant. Lifestyle and health information was collected by questionnaire. Bivariate analyses (controlling for chronological age identified and quantified lifestyle variables associated with perceived facial age. Independent predictors of perceived age were identified by multivariate modelling. Factors which significantly associated with looking younger for one's chronological age included greater years of education (p<0.001, fewer household members (p=0.027, menopausal status (p=0.020, frequency of visiting one's doctor (p=0.013, working indoors (p<0.001, spending less time in the sun (p=0.015, moderate levels of physical activity (p=0.004, higher frequency of teeth cleaning (p<0.001 and more frequent use of facial care products: cleanser (p<0.001; moisturiser (p=0.016 or night cream (p=0.016. Overall, 36.5% of the variation in the difference between perceived and chronological age could be explained by a combination of chronological age and 6 independent lifestyle variables. We have thus identified and quantified a number of factors associated with younger appearance in Chinese women. Presentation of these factors in the context of facial appearance could provide significant motivation for the adoption of a range of healthy behaviours at the level of both individuals and populations.

  19. Energy Impacts of Energy and Indoor Environmental Quality Retrofits of Apartments in California

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Norris, Federico [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-11-01

    Monthly gas and electricity use data from a set of 13 study apartments and 20 control apartments from three apartment buildings (B1 B3) in California were analyzed. The study apartments were retrofit with simultaneous energy savings and indoor environmental quality (IEQ) improvements as the goal. The control apartments were not retrofit. Pre-retrofit modeling indicated annual energy savings of 21percent, 17percent, and 27percent for the study apartments in B1-B3, respectively. Based on a comparison of changes in energy use of study apartments to energy use changes of control apartments, total measured savings of gas energy plus site electrical energy were 28percent in B1, 5percent in B2, and 3percent in B3. Given the small number of study apartments and the substantial changes in energy use within control apartments, the project yielded no conclusive evidence of energy savings. Apartment energy use increased with number of occupants and with floor area; however, the association with occupancy was most evident. Climate differences did not appear to be the major driver for the variability in energy use among apartments. Changes in occupant behaviors affecting energy use may have overwhelmed and obscured the energy savings in this small number of buildings. Much larger prior studies employing similar retrofits indicate that the retrofits usually do save energy.

  20. Improving indoor air quality and thermal comfort in office building by using combination filters

    Science.gov (United States)

    Kabrein, H.; Yusof, M. Z. M.; Hariri, A.; Leman, A. M.; Afandi, A.

    2017-09-01

    Poor indoor air quality and thermal comfort condition in the workspace affected the occupants’ health and work productivity, especially when adapting the recirculation of air in heating ventilation and air-conditioning (HVAC) system. The recirculation of air was implemented in this study by mixing the circulated returned indoor air with the outdoor fresh air. The aims of this study are to assess the indoor thermal comfort and indoor air quality (IAQ) in the office buildings, equipped with combination filters. The air filtration technique consisting minimum efficiency reporting value (MERV) filter and activated carbon fiber (ACF) filter, located before the fan coil units. The findings of the study show that the technique of mixing recirculation air with the fresh air through the combination filters met the recommended thermal comfort condition in the workspace. Furthermore, the result of the post-occupancy evaluation (POE) and the environmental measurements comply with the ASHRAE 55 standard. In addition, the level of CO2 concentration continued to decrease during the period of the measurement.

  1. The Isprs Benchmark on Indoor Modelling

    Science.gov (United States)

    Khoshelham, K.; Díaz Vilariño, L.; Peter, M.; Kang, Z.; Acharya, D.

    2017-09-01

    Automated generation of 3D indoor models from point cloud data has been a topic of intensive research in recent years. While results on various datasets have been reported in literature, a comparison of the performance of different methods has not been possible due to the lack of benchmark datasets and a common evaluation framework. The ISPRS benchmark on indoor modelling aims to address this issue by providing a public benchmark dataset and an evaluation framework for performance comparison of indoor modelling methods. In this paper, we present the benchmark dataset comprising several point clouds of indoor environments captured by different sensors. We also discuss the evaluation and comparison of indoor modelling methods based on manually created reference models and appropriate quality evaluation criteria. The benchmark dataset is available for download at: html"target="_blank">http://www2.isprs.org/commissions/comm4/wg5/benchmark-on-indoor-modelling.html.

  2. Indoor/Outdoor Air Quality Assessment at School near the Steel Plant in Taranto (Italy

    Directory of Open Access Journals (Sweden)

    A. Di Gilio

    2017-01-01

    Full Text Available This study aims to investigate the air quality in primary school placed in district of Taranto (south of Italy, an area of high environmental risk because of closeness between large industrial complex and urban settlement. The chemical characterization of PM2.5 was performed to identify origin of pollutants detected inside school and the comparison between indoor and outdoor levels of PAHs and metals allowed evaluating intrusion of outdoor pollutants or the existence of specific indoor sources. The results showed that the indoor and outdoor levels of PM2.5, BaP, Cd, Ni, As, and Pb never exceeded the target values issued by World Health Organization (WHO. Nevertheless, high metals and PAHs concentrations were detected especially when school were downwind to the steel plant. The I/O ratio showed the impact of outdoor pollutants, especially of industrial markers as Fe, Mn, Zn, and Pb, on indoor air quality. This result was confirmed by values of diagnostic ratio as B(aP/B(gP, IP/(IP + BgP, BaP/Chry, and BaP/(BaP + Chry, which showed range characteristics of coke and coal combustion. However, Ni and As showed I/O ratio of 2.5 and 1.4, respectively, suggesting the presence of indoor sources.

  3. Controlling Indoor Air Pollution from Moxibustion

    Directory of Open Access Journals (Sweden)

    Chung-Yen Lu

    2016-06-01

    Full Text Available Indoor air quality (IAQ control of hospitals plays a critical role in protecting both hospital staffs and patients, particularly those who are highly susceptible to the adverse effects of indoor noxious hazards. However, moxibustion in outpatient departments (OPDs of traditional Chinese medicine (TCM may be a source of indoor air pollution in hospitals. Some studies have investigated indoor air pollution during moxibustion in Chinese medicine clinics (CMCs and moxibustion rooms, demonstrating elevated air pollutants that pose a threat to the health of medical staff and patients. Our study investigated the indoor air pollutants of indoor carbon dioxide (CO2, carbon monoxide (CO, formaldehyde (HCHO, total volatile organic compounds (TVOCs, airborne particulate matter with a diameter of ≤10 µm (PM10 and ≤2.5 µm (PM2.5 during moxibustion in an acupuncture and moxibustion room of the OPD in a hospital in Taipei. To evaluate the different control strategies for indoor air pollution from moxibution, a comparison of air pollutants during moxibution among the methods of using alternative old moxa wools, local exhaust ventilation and an air cleaner was conducted. In this study, burning alternative old moxa wools for moxibustion obviously reduced all gaseous pollutants except for aerosols comparing burning fresh moxa wools. Using local exhaust ventilation reduced most of the aerosols after burning moxa. We also found that using an air cleaner was inefficient for controlling indoor air pollutants, particularly gaseous pollutants. Therefore, combining replacing alternative old moxa wools and local exhaust ventilation could be a suitable design for controlling indoor air pollution during moxibustion therapy.

  4. Multi-dimensional indoor location information model

    NARCIS (Netherlands)

    Xiong, Q.; Zhu, Q.; Zlatanova, S.; Huang, L.; Zhou, Y.; Du, Z.

    2013-01-01

    Aiming at the increasing requirements of seamless indoor and outdoor navigation and location service, a Chinese standard of Multidimensional Indoor Location Information Model is being developed, which defines ontology of indoor location. The model is complementary to 3D concepts like CityGML and

  5. Psychotropic substances in indoor environments.

    Science.gov (United States)

    Cecinato, Angelo; Romagnoli, Paola; Perilli, Mattia; Patriarca, Claudia; Balducci, Catia

    2014-10-01

    The presence of drugs in outdoor air has been established, but few investigations have been conducted indoors. This study focused on psychotropic substances (PSs) at three schools, four homes and one office in Rome, Italy. The indoor drug concentrations and the relationships with the outdoor atmosphere were investigated. The optimised monitoring procedure allowed for the determination of cocaine, cannabinoids and particulate fractions of nicotine and caffeine. In-field experiments were performed during the winter, spring and summer seasons. Psychotropic substances were observed in all indoor locations. The indoor concentrations often exceeded those recorded both outdoors at the same sites and at the atmospheric pollution control network stations, indicating that the drugs were released into the air at the inside sites or were more persistent. During winter, the relative concentrations of cannabinol, cannabidiol and tetrahydrocannabinol depended on site and indoor/outdoor location at the site. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Design of an Indoor Sonic Boom Simulator at NASA Langley Research Center

    Science.gov (United States)

    Klos, Jacob; Sullivan, Brenda M.; Shepherd, Kevin P.

    2008-01-01

    Construction of a simulator to recreate the soundscape inside residential buildings exposed to sonic booms is scheduled to start during the summer of 2008 at NASA Langley Research Center. The new facility should be complete by the end of the year. The design of the simulator allows independent control of several factors that create the indoor soundscape. Variables that will be isolated include such factors as boom duration, overpressure, rise time, spectral shape, level of rattle, level of squeak, source of rattle and squeak, level of vibration and source of vibration. Test subjects inside the simulator will be asked to judge the simulated soundscape, which will represent realistic indoor boom exposure. Ultimately, this simulator will be used to develop a functional relationship between human response and the sound characteristics creating the indoor soundscape. A conceptual design has been developed by NASA personnel, and is currently being vetted through small-scale risk reduction tests that are being performed in-house. The purpose of this document is to introduce the conceptual design, identify how the indoor response will be simulated, briefly outline some of the risk reduction tests that have been completed to vet the design, and discuss the impact of these tests on the simulator design.

  7. Indoor secondary organic aerosols formation from ozonolysis of monoterpene: An example of d-limonene with ammonia and potential impacts on pulmonary inflammations.

    Science.gov (United States)

    Niu, Xinyi; Ho, Steven Sai Hang; Ho, Kin Fai; Huang, Yu; Cao, Junji; Shen, Zhenxing; Sun, Jian; Wang, Xiumei; Wang, Yu; Lee, Shuncheng; Huang, Rujin

    2017-02-01

    Monoterpene is one class of biogenic volatile organic compounds (BVOCs) which widely presents in household cleaning products and air fresheners. It plays reactive role in secondary organic aerosols (SOAs) formation with ozone (O 3 ) in indoor environments. Such ozonolysis can be influenced by the presence of gaseous pollutants such as ammonia (NH 3 ). This study focuses on investigations of ozone-initiated formation of indoor SOAs with d-limonene, one of the most abundant indoor monoterpenes, in a large environmental chamber. The maximum total particle number concentration from the ozonolysis in the presence of NH 3 was 60% higher than that in the absence of NH 3 . Both of the nuclei coagulation and condensation involve in the SOAs growth. The potential risks of pulmonary injury for the exposure to the secondary particles formed were presented with the indexes of tumor necrosis factor-α (TNF-α), interleukin-6 (IL-6) and interleukin-10 (IL-10) expression levels in bronchoalveolar lavage fluid (BALF) upon intratracheal instillation in mice lung for 6 and 12h. The results indicated that there was 22-39% stronger pulmonary inflammatory effect on the particles generated with NH 3 . This is a pilot study which demonstrates the toxicities of the indoor SOAs formed from the ozonolysis of a monoterpene. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Neural computing thermal comfort index PMV for the indoor environment intelligent control system

    Science.gov (United States)

    Liu, Chang; Chen, Yifei

    2013-03-01

    Providing indoor thermal comfort and saving energy are two main goals of indoor environmental control system. An intelligent comfort control system by combining the intelligent control and minimum power control strategies for the indoor environment is presented in this paper. In the system, for realizing the comfort control, the predicted mean vote (PMV) is designed as the control goal, and with chastening formulas of PMV, it is controlled to optimize for improving indoor comfort lever by considering six comfort related variables. On the other hand, a RBF neural network based on genetic algorithm is designed to calculate PMV for better performance and overcoming the nonlinear feature of the PMV calculation better. The formulas given in the paper are presented for calculating the expected output values basing on the input samples, and the RBF network model is trained depending on input samples and the expected output values. The simulation result is proved that the design of the intelligent calculation method is valid. Moreover, this method has a lot of advancements such as high precision, fast dynamic response and good system performance are reached, it can be used in practice with requested calculating error.

  9. The Relationships Between Female Adolescents' Media Use, Indoor Tanning Outcome Expectations, and Behavioral Intentions.

    Science.gov (United States)

    Myrick, Jessica Gall; Noar, Seth M; Kelley, Dannielle; Zeitany, Alexandra E

    2017-06-01

    Unlike other types of cancer, skin cancer incidence rates are on the rise and adolescent females are particularly likely to tan indoors, a major risk factor. However, little research has examined the role of media use in encouraging or discouraging this dangerous behavior in this population. To empirically assess the links between media use, indoor tanning-related outcome expectations, and behavioral intentions. A survey of adolescent females ( N = 510) ages 15 to 18 in the Southeastern United States assessed demographics, types of media use, and indoor tanning intentions. Significant correlations between media use and indoor tanning outcome expectations were found. Use of interpersonal and social media (i.e., talking on the phone, texting, and online social media) were positively associated with positive outcome expectations about indoor tanning and negatively associated with negative outcome expectations. A path analysis revealed that interpersonal/social media use had indirect associations with indoor tanning intentions via tanning outcome expectations. Mass media use (e.g., news media, entertainment media, and magazines) was not significantly associated with most indoor tanning outcome expectations but did have a direct negative association with behavioral intentions. There are important relationships between media use, indoor tanning outcome expectations, and behavioral intentions. Interpersonal and social media use may help cultivate outcome expectations that encourage indoor tanning, which in turn may increase intentions to tan, while news media consumption in particular may reduce intentions to tan. These findings highlight the social nature of adolescent females and point to specific intervention channels for reducing indoor tanning among this population.

  10. The multitude and diversity of environmental carcinogens

    International Nuclear Information System (INIS)

    Belpomme, D.; Irigaray, P.; Hardell, L.; Clapp, R.; Montagnier, L.; Epstein, S.; Sasco, A.J.

    2007-01-01

    We have recently proposed that lifestyle-related factors, screening and aging cannot fully account for the present overall growing incidence of cancer. In order to propose the concept that in addition to lifestyle related factors, exogenous environmental factors may play a more important role in carcinogenesis than it is expected, and may therefore account for the growing incidence of cancer, we overview herein environmental factors, rated as certainly or potentially carcinogenic by the International Agency for Research on Cancer (IARC). We thus analyze the carcinogenic effect of microorganisms (including viruses), radiations (including radioactivity, UV and pulsed electromagnetic fields) and xenochemicals. Chemicals related to environmental pollution appear to be of critical importance, since they can induce occupational cancers as well as other cancers. Of major concerns are: outdoor air pollution by carbon particles associated with polycyclic aromatic hydrocarbons; indoor air pollution by environmental tobacco smoke, formaldehyde and volatile organic compounds such as benzene and 1,3 butadiene, which may particularly affect children, and food pollution by food additives and by carcinogenic contaminants such as nitrates, pesticides, dioxins and other organochlorines. In addition, carcinogenic metals and metalloids, pharmaceutical medicines and cosmetics may be involved. Although the risk fraction attributable to environmental factors is still unknown, this long list of carcinogenic and especially mutagenic factors supports our working hypothesis according to which numerous cancers may in fact be caused by the recent modification of our environment

  11. NFC Internal: An Indoor Navigation System

    Science.gov (United States)

    Ozdenizci, Busra; Coskun, Vedat; Ok, Kerem

    2015-01-01

    Indoor navigation systems have recently become a popular research field due to the lack of GPS signals indoors. Several indoors navigation systems have already been proposed in order to eliminate deficiencies; however each of them has several technical and usability limitations. In this study, we propose NFC Internal, a Near Field Communication (NFC)-based indoor navigation system, which enables users to navigate through a building or a complex by enabling a simple location update, simply by touching NFC tags those are spread around and orient users to the destination. In this paper, we initially present the system requirements, give the design details and study the viability of NFC Internal with a prototype application and a case study. Moreover, we evaluate the performance of the system and compare it with existing indoor navigation systems. It is seen that NFC Internal has considerable advantages and significant contributions to existing indoor navigation systems in terms of security and privacy, cost, performance, robustness, complexity, user preference and commercial availability. PMID:25825976

  12. Introduction to Indoor Air Quality

    Science.gov (United States)

    ... Offices Regional Offices Labs and Research Centers Indoor Air Quality (IAQ) Contact Us Share Introduction to Indoor Air Quality Health Effects Primary Causes Identifying Problems Improving IAQ ...

  13. A sensitivity study of parameters in the Nazaroff-Cass IAQ model with respect to indoor concentrations of O3, NO, NO2

    International Nuclear Information System (INIS)

    Drakou, G.; Zerefos, C.; Ziomas, I.

    2000-01-01

    The indoor O 3 , NO, NO 2 concentrations and their corresponding indoor/outdoor (I/O) concentration ratios are predicted in this paper for some representative buildings, using the Nazaroff-Cass indoor air quality models. This paper presents and systemises the relationship between indoor and air pollution concentrations and the buildings' design, use and operation. The building parameters which are determined to be main factors affecting the air pollutant concentrations are: the physical dimensions of the building and the materials of construction, the buildings' air exchange rate with outdoors and the indoor air pollutant sources. Changes of ultraviolet photon fluxes, of temperatures and of relative humidity indoors, have little effect on indoor O 3 , NO and NO 2 concentrations, for air exchange rates above 0.5 ach. Special attention must be given when a building has a very low air exchange rate, under which conditions the effect of a small change in any of the factors determining the indoor air quality of the building will be much more noticeable than in a building with high air exchange rate. (Author)

  14. Indoor rock climbing: who gets injured?

    Science.gov (United States)

    Wright, D M; Royle, T J; Marshall, T

    2001-06-01

    To determine the frequency of overuse injury in indoor climbers, the common sites of such injury, and the factors that influence the probability that a climber will have sustained an overuse injury while climbing indoors. A semisupervised questionnaire was used to survey overuse injury in 295 spectators and competitors at the Entre-Prises World Climbing Championships held in Birmingham 3-5 December 1999. Statistical analysis included simple cross tabulations, calculation of odds ratios, and multiple logistic regression to explore the effect of several factors simultaneously. Some 44% of respondents had sustained an overuse injury, 19% at more than one site. The most common site of injury was the fingers. Univariate analysis showed that the probability of having sustained a climbing injury is higher in men (p = 0.009), those who have climbed for more than 10 years (p = 0.006), those who climb harder routes (p<0.0005), and those who boulder or lead more than they top rope (p<0.0005). The relation between lead grade and climbing injury is linear. Multivariate analysis removed the effect of sex as an independent predictor. Many climbers sustain overuse injury. The most at risk are those with the most ability and dedication to climbing. Climbers should be aware of the risk factors that influence injury and be able to spot the signs and symptoms of injury once they occur.

  15. Indoor air quality of everyday use spaces dedicated to specific purposes-a review.

    Science.gov (United States)

    Marć, Mariusz; Śmiełowska, Monika; Namieśnik, Jacek; Zabiegała, Bożena

    2018-01-01

    According to literature data, some of the main factors which significantly affect the quality of the indoor environment in residential households or apartments are human activities such as cooking, smoking, cleaning, and indoor exercising. The paper presents a literature overview related to air quality in everyday use spaces dedicated to specific purposes which are integral parts of residential buildings, such as kitchens, basements, and individual garages. Some aspects of air quality in large-scale car parks, as a specific type of indoor environment, are also discussed. All those areas are characterized by relatively short time use. On the other hand, high and very high concentration levels of xenobiotics can be observed, resulting in higher exposure risk. The main compounds or group of chemical compounds are presented and discussed. The main factors influencing the type and amount of chemical pollutants present in the air of such areas are indicated.

  16. 9 CFR 3.102 - Facilities, indoor.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Facilities, indoor. 3.102 Section 3... Marine Mammals Facilities and Operating Standards § 3.102 Facilities, indoor. (a) Ambient temperature. The air and water temperatures in indoor facilities shall be sufficiently regulated by heating or...

  17. INDOOR AIR POLLUTION

    OpenAIRE

    Ahmet Soysal; Yucel Demiral

    2007-01-01

    The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas...

  18. Indoor Multi-Dimensional Location GML and Its Application for Ubiquitous Indoor Location Services

    NARCIS (Netherlands)

    Zhu, Qing; Li, Yun; Xiong, Qing; Zlatanova, S.; Ding, Yulin; Zhang, Yeting; Zhou, Yan

    2016-01-01

    The Open Geospatial Consortium (OGC) Geography Markup Language (GML) standard provides basic types and a framework for defining geo-informational data models such as CityGML and IndoorGML, which provide standard information models for 3D city modelling and lightweight indoor network navigation.

  19. An Indoor Location-Based Control System Using Bluetooth Beacons for IoT Systems.

    Science.gov (United States)

    Huh, Jun-Ho; Seo, Kyungryong

    2017-12-19

    The indoor location-based control system estimates the indoor position of a user to provide the service he/she requires. The major elements involved in the system are the localization server, service-provision client, user application positioning technology. The localization server controls access of terminal devices (e.g., Smart Phones and other wireless devices) to determine their locations within a specified space first and then the service-provision client initiates required services such as indoor navigation and monitoring/surveillance. The user application provides necessary data to let the server to localize the devices or allow the user to receive various services from the client. The major technological elements involved in this system are indoor space partition method, Bluetooth 4.0, RSSI (Received Signal Strength Indication) and trilateration. The system also employs the BLE communication technology when determining the position of the user in an indoor space. The position information obtained is then used to control a specific device(s). These technologies are fundamental in achieving a "Smart Living". An indoor location-based control system that provides services by estimating user's indoor locations has been implemented in this study (First scenario). The algorithm introduced in this study (Second scenario) is effective in extracting valid samples from the RSSI dataset but has it has some drawbacks as well. Although we used a range-average algorithm that measures the shortest distance, there are some limitations because the measurement results depend on the sample size and the sample efficiency depends on sampling speeds and environmental changes. However, the Bluetooth system can be implemented at a relatively low cost so that once the problem of precision is solved, it can be applied to various fields.

  20. An Indoor Location-Based Control System Using Bluetooth Beacons for IoT Systems

    Directory of Open Access Journals (Sweden)

    Jun-Ho Huh

    2017-12-01

    Full Text Available The indoor location-based control system estimates the indoor position of a user to provide the service he/she requires. The major elements involved in the system are the localization server, service-provision client, user application positioning technology. The localization server controls access of terminal devices (e.g., Smart Phones and other wireless devices to determine their locations within a specified space first and then the service-provision client initiates required services such as indoor navigation and monitoring/surveillance. The user application provides necessary data to let the server to localize the devices or allow the user to receive various services from the client. The major technological elements involved in this system are indoor space partition method, Bluetooth 4.0, RSSI (Received Signal Strength Indication and trilateration. The system also employs the BLE communication technology when determining the position of the user in an indoor space. The position information obtained is then used to control a specific device(s. These technologies are fundamental in achieving a “Smart Living”. An indoor location-based control system that provides services by estimating user’s indoor locations has been implemented in this study (First scenario. The algorithm introduced in this study (Second scenario is effective in extracting valid samples from the RSSI dataset but has it has some drawbacks as well. Although we used a range-average algorithm that measures the shortest distance, there are some limitations because the measurement results depend on the sample size and the sample efficiency depends on sampling speeds and environmental changes. However, the Bluetooth system can be implemented at a relatively low cost so that once the problem of precision is solved, it can be applied to various fields.

  1. Capturing Hotspots For Constrained Indoor Movement

    DEFF Research Database (Denmark)

    Ahmed, Tanvir; Pedersen, Torben Bach; Lu, Hua

    2013-01-01

    Finding the hotspots in large indoor spaces is very important for getting overloaded locations, security, crowd management, indoor navigation and guidance. The tracking data coming from indoor tracking are huge in volume and not readily available for finding hotspots. This paper presents a graph......-based model for constrained indoor movement that can map the tracking records into mapping records which represent the entry and exit times of an object in a particular location. Then it discusses the hotspots extraction technique from the mapping records....

  2. Current implications of past DDT indoor spraying in Oman

    Czech Academy of Sciences Publication Activity Database

    Booji, P.; Holoubek, I.; Klánová, J.; Kohoutek, J.; Dvorská, Alice; Magulová, K.; Al-Zadjali, S.; Čupr, P.

    2016-01-01

    Roč. 550, apr (2016), s. 231-240 ISSN 0048-9697 Institutional support: RVO:67179843 Keywords : DDT * Residual indoor spraying * Human risk assessment * Cancer risk * Region-specific half-life Subject RIV: EH - Ecology, Behaviour Impact factor: 4.900, year: 2016

  3. Indoor Coal Use and Early Childhood Growth

    Czech Academy of Sciences Publication Activity Database

    Ghosh, R.; Amirian, E.; Dostál, Miroslav; Šrám, Radim; Hertz-Picciotto, I.

    2011-01-01

    Roč. 165, č. 6 (2011), s. 492-497 ISSN 1072-4710 R&D Projects: GA MŽP(CZ) SP/1B3/50/07 Institutional research plan: CEZ:AV0Z50390512 Keywords : air pollution, * coal heating * indoor air pollutants Subject RIV: DN - Health Impact of the Environment Quality Impact factor: 4.140, year: 2011

  4. Ventilation influence upon indoor air radon level

    International Nuclear Information System (INIS)

    Tian Deyuan

    1995-01-01

    Levels of indoor radon in air are studied by a continuous electrostatic radon monitor under normal living conditions to evaluate the influence of air conditioned ventilation on indoor air radon level. Results show that the indoor air radon concentrations are not much more than those without household conditioner living condition, although using household conditioner requires a sealed room which should lead to a higher radon level. Turning on air conditioner helps lower indoor radon level. Therefore, the total indoor air Rn levels are normal > ventilation > exhaust or in-draft > exhaust plus in-draft

  5. Managing Indoor Air Quality in Schools.

    Science.gov (United States)

    Woolums, Jennifer

    This publication examines the causes and effects of poor indoor air quality and provides information for reducing exposure to indoor contaminants in schools. It discusses the various indoor pollutants found in schools, including dust, chemical agents, gases, and volatile organic compounds; where they are found in schools; and their health effects…

  6. Indoor climate design for a monumental building with periodic high indoor moisture loads

    NARCIS (Netherlands)

    Schijndel, van A.W.M.; Lony, R.J.M.; Schellen, H.L.

    2008-01-01

    The paper presents a case study on the performance based design for the indoor climate of a monumental building with periodic high indoor moisture loads. Several scenarios of the past performance and new control classes are simulated and evaluated. The results include the influence of hygric inertia

  7. Indoor air quality: a UK perspective

    International Nuclear Information System (INIS)

    Wadge, A.

    1995-01-01

    Outdoor air quality has generally improved in the UK over the last 2 decades but during this period changing conditions within the home have tended to reduce ventilation and increase the opportunity for accumulation of undesirable levels of indoor air pollutants. Information obtained from laboratory and epidemiological studies suggest that indoor air pollutants are an important cause of avoidable morbidity and mortality in the UK. This paper reviews the major indoor air pollutants of concern in the UK and considers some of the special issues relevant to indoor environment. (author) 3 figs., 37 refs

  8. Indoor localization using magnetic fields

    Science.gov (United States)

    Pathapati Subbu, Kalyan Sasidhar

    Indoor localization consists of locating oneself inside new buildings. GPS does not work indoors due to multipath reflection and signal blockage. WiFi based systems assume ubiquitous availability and infrastructure based systems require expensive installations, hence making indoor localization an open problem. This dissertation consists of solving the problem of indoor localization by thoroughly exploiting the indoor ambient magnetic fields comprising mainly of disturbances termed as anomalies in the Earth's magnetic field caused by pillars, doors and elevators in hallways which are ferromagnetic in nature. By observing uniqueness in magnetic signatures collected from different campus buildings, the work presents the identification of landmarks and guideposts from these signatures and further develops magnetic maps of buildings - all of which can be used to locate and navigate people indoors. To understand the reason behind these anomalies, first a comparison between the measured and model generated Earth's magnetic field is made, verifying the presence of a constant field without any disturbances. Then by modeling the magnetic field behavior of different pillars such as steel reinforced concrete, solid steel, and other structures like doors and elevators, the interaction of the Earth's field with the ferromagnetic fields is described thereby explaining the causes of the uniqueness in the signatures that comprise these disturbances. Next, by employing the dynamic time warping algorithm to account for time differences in signatures obtained from users walking at different speeds, an indoor localization application capable of classifying locations using the magnetic signatures is developed solely on the smart phone. The application required users to walk short distances of 3-6 m anywhere in hallway to be located with accuracies of 80-99%. The classification framework was further validated with over 90% accuracies using model generated magnetic signatures representing

  9. Intrinsic vs. spurious long-range memory in high-frequency records of environmental radioactivity. Critical re-assessment and application to indoor 222Rn concentrations from Coimbra, Portugal

    Science.gov (United States)

    Donner, R. V.; Potirakis, S. M.; Barbosa, S. M.; Matos, J. A. O.; Pereira, A. J. S. C.; Neves, L. J. P. F.

    2015-05-01

    The presence or absence of long-range correlations in the environmental radioactivity fluctuations has recently attracted considerable interest. Among a multiplicity of practically relevant applications, identifying and disentangling the environmental factors controlling the variable concentrations of the radioactive noble gas radon is important for estimating its effect on human health and the efficiency of possible measures for reducing the corresponding exposition. In this work, we present a critical re-assessment of a multiplicity of complementary methods that have been previously applied for evaluating the presence of long-range correlations and fractal scaling in environmental radon variations with a particular focus on the specific properties of the underlying time series. As an illustrative case study, we subsequently re-analyze two high-frequency records of indoor radon concentrations from Coimbra, Portugal, each of which spans several weeks of continuous measurements at a high temporal resolution of five minutes.Our results reveal that at the study site, radon concentrations exhibit complex multi-scale dynamics with qualitatively different properties at different time-scales: (i) essentially white noise in the high-frequency part (up to time-scales of about one hour), (ii) spurious indications of a non-stationary, apparently long-range correlated process (at time scales between some hours and one day) arising from marked periodic components, and (iii) low-frequency variability indicating a true long-range dependent process. In the presence of such multi-scale variability, common estimators of long-range memory in time series are prone to fail if applied to the raw data without previous separation of time-scales with qualitatively different dynamics.

  10. Indoor smoking ordinances in workplaces and public places in Kansas.

    Science.gov (United States)

    Neuberger, John S; Davis, Ken; Nazir, Niaman; Dunton, Nancy; Winn, Kimberly; Jacquot, Sandy; Moler, Don

    2010-08-01

    The purpose of this study was to investigate the preferences of elected city officials regarding the need for a statewide clean indoor air law and to analyze the content of local smoking ordinances. A survey of elected officials in 57 larger Kansas cities obtained information on the perceived need for statewide legislation, venues to be covered, and motivating factors. Clean indoor air ordinances from all Kansas cities were analyzed by venue. The survey response rate was 190 out of 377 (50.4%) for elected officials. Over 70% of the respondents favored or strongly favored greater restrictions on indoor smoking. Sixty percent favored statewide legislation. Among these, over 80% favored restrictions in health care facilities, theaters, indoor sports arenas (including bowling alleys), restaurants, shopping malls, lobbies, enclosed spaces in outdoor arenas, and hotel/motel rooms. Officials who had never smoked favored a more restrictive approach. Employee and public health concerns were cited as influential by 76%-79% of respondents. Thirty-eight ordinances, covering over half of the state's population, were examined. They varied considerably in their exemptions. Official's attitudes toward smoking regulations were associated with their smoking status. The examination of existing ordinances revealed a piecemeal approach to smoking regulations.

  11. High indoor radon variations and the thermal behavior of eskers

    International Nuclear Information System (INIS)

    Arvela, H.; Voutilainen, A.; Honkamaa, T.; Rosenberg, A.

    1994-01-01

    Measurements of indoor radon concentrations in houses built on the Pispala esker in the city of Tampere were taken. The objective was to find connections between indoor radon concentrations, esker topography, and meteorological factors. The results show that not only the permeable soil but also subterranean air-flows in the esker strongly affect the indoor radon concentrations. The difference in temperature between the soil air inside the esker and the outdoor air compels the subterranean air to stream between the upper and lower esker areas. In winter, the radon concentrations are amplified in the upper esker areas where air flows out from the esker. In summer, concentrations are amplified in certain slope zones. In addition, wind direction affects the soil air and indoor radon concentrations when hitting the slopes at right angles. Winter-summer concentration ratios are typically in the range of 3-20 in areas with amplified winter concentration, and 0.1-0.5 in areas with amplified summer concentrations. A combination of winter and summer measurements provides the best basis for making mitigation decisions. On eskers special attention must be paid to building technology because of radon. 9 refs., 7 figs., 1 tab

  12. Indoor Radon Concentration Related to Different Radon Areas and Indoor Radon Prediction

    Science.gov (United States)

    Juhásová Šenitková, Ingrid; Šál, Jiří

    2017-12-01

    Indoor radon has been observed in the buildings at areas with different radon risk potential. Preventive measures are based on control of main potential radon sources (soil gas, building material and supplied water) to avoid building of new houses above recommended indoor radon level 200 Bq/m3. Radon risk (index) estimation of individual building site bedrock in case of new house siting and building protection according technical building code are obligatory. Remedial actions in buildings built at high radon risk areas were carried out principally by unforced ventilation and anti-radon insulation. Significant differences were found in the level of radon concentration between rooms where radon reduction techniques were designed and those where it was not designed. The mathematical model based on radon exhalation from soil has been developed to describe the physical processes determining indoor radon concentration. The model is focused on combined radon diffusion through the slab and advection through the gap from sub-slab soil. In this model, radon emanated from building materials is considered not having a significant contribution to indoor radon concentration. Dimensional analysis and Gauss-Newton nonlinear least squares parametric regression were used to simplify the problem, identify essential input variables and find parameter values. The presented verification case study is introduced for real buildings with respect to various underground construction types. Presented paper gives picture of possible mathematical approach to indoor radon concentration prediction.

  13. Reducing indoor residential exposures to outdoor pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.; Matson, Nance E.

    2003-07-01

    The basic strategy for providing indoor air quality in residences is to dilute indoor sources with outdoor air. This strategy assumes that the outdoor air does not have pollutants at harmful levels or that the outdoor air is, at least, less polluted than the indoor air. When this is not the case, different strategies need to be employed to ensure adequate air quality in the indoor environment. These strategies include ventilation systems, filtration and other measures. These strategies can be used for several types of outdoor pollution, including smog, particulates and toxic air pollutants. This report reviews the impacts that typical outdoor air pollutants can have on the indoor environment and provides design and operational guidance for mitigating them. Poor quality air cannot be used for diluting indoor contaminants, but more generally it can become an indoor contaminant itself. This paper discusses strategies that use the building as protection against potentially hazardous outdoor pollutants, including widespread pollutants, accidental events, and potential attacks.

  14. Good practices in managing work-related indoor air problems: a psychosocial perspective.

    Science.gov (United States)

    Lahtinen, Marjaana; Huuhtanen, Pekka; Vähämäki, Kari; Kähkönen, Erkki; Mussalo-Rauhamaa, Helena; Reijula, Kari

    2004-07-01

    Indoor air problems at workplaces are often exceedingly complex. Technical questions are interrelated with the dynamics of the work community, and the cooperation and interaction skills of the parties involved in the problem solving process are also put to the test. The objective of our study was to analyze the process of managing and solving indoor air problems from a psychosocial perspective. This collective case study was based on data from questionnaires, interviews and various documentary materials. Technical inspections of the buildings and indoor air measurements were also carried out. The following four factors best differentiated successful cases from impeded cases: extensive multiprofessional collaboration and participative action, systematic action and perseverance, investment in information and communication, and process thinking and learning. The study also proposed a theoretical model for the role of the psychosocial work environment in indoor air problems. The expertise related to social and human aspects of problem solving plays a significant role in solving indoor air problems. Failures to properly handle these aspects may lead to resources being wasted and result in a problematic situation becoming stagnant or worse. Copyright 2004 Wiley-Liss, Inc.

  15. Assessment of indoor environment in Paris child day care centers.

    Science.gov (United States)

    Roda, Célina; Barral, Sophie; Ravelomanantsoa, Hanitriniala; Dusséaux, Murielle; Tribout, Martin; Le Moullec, Yvon; Momas, Isabelle

    2011-11-01

    Children are sensitive to indoor environmental pollution. Up until now there has been a lack of data on air quality in child day care centers. The aim of this study is to document the indoor environment quality of Paris child day care centers by repeated measurements, and to compare pollutant levels in child day care centers with levels in Paris dwellings. We selected 28 child day care centers frequented by a random sample of babies who participated in the PARIS birth cohort environmental investigation, and visited the child day care centers for one week twice in one year. Biological contaminants assessed were fungi, endotoxin, dust mite allergens, and chemical pollutants: aldehydes, volatile organic compounds and nitrogen dioxide (NO2). Relative humidity, temperature, and carbon dioxide levels were measured simultaneously. A standardized questionnaire was used to gather information about the buildings and their inhabitants. Airborne endotoxin levels in child day care centers were higher than those found in Paris dwellings. Dust mite allergens in child day care centers were below the threshold level for sensitization in the majority of samples, and in common with dwelling samples. Penicillium and Cladosporium were the most commonly identified genera fungi. The child day care center indoor/outdoor ratio for most chemical pollutants was above unity except for NO2, the levels for NO2 being significantly higher than those measured in homes. Chemical and biological contamination in child day care centers appears to be low, apart from endotoxin and NO2. Failure to take child exposure in child day care centers into account could result in an overestimation of children's exposure to other pollutants. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Environmental Factors, Toxicants and Systemic Lupus Erythematosus

    Directory of Open Access Journals (Sweden)

    Anselm Mak

    2014-09-01

    Full Text Available Systemic lupus erythematosus (SLE is an immune-complex-mediated multi-systemic autoimmune condition of multifactorial etiology, which mainly affects young women. It is currently believed that the onset of SLE and lupus flares are triggered by various environmental factors in genetically susceptible individuals. Various environmental agents and toxicants, such as cigarette smoke, alcohol, occupationally- and non-occupationally-related chemicals, ultraviolet light, infections, sex hormones and certain medications and vaccines, have been implicated to induce SLE onset or flares in a number case series, case-control and population-based cohort studies and very few randomized controlled trials. Here, we will describe some of these recognized environmental lupus triggering and perpetuating factors and explain how these factors potentially bias the immune system towards autoimmunity through their interactions with genetic and epigenetic alterations. Further in-depth exploration of how potentially important environmental factors mechanistically interact with the immune system and the genome, which trigger the onset of SLE and lupus flares, will certainly be one of the plausible steps to prevent the onset and to decelerate the progress of the disease.

  17. Role of environmental factors in the timing of puberty

    DEFF Research Database (Denmark)

    Euling, S.Y.; Selevan, S.G.; Pescovitz, O.H.

    2008-01-01

    Puberty-timing measures have historically been used as indicators of adequate nutrition and growth. More recently, these measures have been examined in relation to exposure to estrogenic or antiandrogenic agents, as well as other environmental factors. The scientific community has debated whether...... puberty timing is occurring earlier today than in the mid-1900s in the United States and, if so, whether environmental factors play a role; however, no one has asked a multidisciplinary panel to resolve this question. Thus, a multidisciplinary expert panel jointly sponsored by the US Environmental...... Protection Agency, the National Institute of Environmental Health Sciences, and Serono Symposia International was convened to examine the evidence of a secular trend, identify potential environmental factors of concern, and identify research needs regarding environmental factors and puberty timing at "The...

  18. NFC Internal: An Indoor Navigation System

    Directory of Open Access Journals (Sweden)

    Busra Ozdenizci

    2015-03-01

    Full Text Available Indoor navigation systems have recently become a popular research field due to the lack of GPS signals indoors. Several indoors navigation systems have already been proposed in order to eliminate deficiencies; however each of them has several technical and usability limitations. In this study, we propose NFC Internal, a Near Field Communication (NFC-based indoor navigation system, which enables users to navigate through a building or a complex by enabling a simple location update, simply by touching NFC tags those are spread around and orient users to the destination. In this paper, we initially present the system requirements, give the design details and study the viability of NFC Internal with a prototype application and a case study. Moreover, we evaluate the performance of the system and compare it with existing indoor navigation systems. It is seen that NFC Internal has considerable advantages and significant contributions to existing indoor navigation systems in terms of security and privacy, cost, performance, robustness, complexity, user preference and commercial availability.

  19. Assessment of radiological effect of the indoor radon and its progeny

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subbaramu, M.C.; Mishra, U.C.

    1988-01-01

    Of all the sources of environmental radiation, radon and its progeny are considered to be responsible for a significant dose to man, especially when they are in enclosed areas like underground mines, caves, cellars, poorly designed and badly ventilated houses. Linear extrapolation from the dose response value of the uranium miners exposed to higher levels of radon and its daughters also suggest that the majority of the lung cancer incidence could be due to radon. Higher indoor radon levels and shift in the disequilibrium of the progeny concentration in dwellings caused by the lower ventilation rate leads to severalfold increase of lung cancer incidence from radon. The large risk which is anticipated calls for further studies in this field and may also lead to the conclusion that the slight, but much feared, burden due to man-made radioactivity could be more than compensated by controlling critical segments of the environmental radioactivity. In this report the study of risk due to breathing of indoor radon is briefly reviewed. Dose equivalent to the exposed tissue of the respiratory tract of the people living in dwellings are evaluated. Like most of the risk assessment of low level radiation, the effort to quantify the effect of radon in terms of death rate dose due to lung cancer attributable to radon levels indoors, has to rely on the extrapolation from the effects of the higher exposure rate. In situations where soil or building materials contain elevated radium levels, living in energy efficient houses may be as dangerous as heavy smoking. (author). 8 tabs., 5 figs., 41 refs

  20. Dependence of indoor-pollutant concentrations on sources, ventilation rates, and other removal factors

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.; Grimsrud, D.T.

    1983-01-01

    The behavior of several classes of chemical and physical pollutants include emissions from combustion appliances, radon and its progeny, formaldehyde, and other organic compounds. Current research at Lawrence Berkeley Laboratory is described and research needs in the area of indoor air quality is pointed out

  1. Debating the future of comfort: environmental sustainability, energy consumption and the indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    Chappells, H.; Shove, E.

    2005-02-01

    Vast quantities of energy are consumed in heating and cooling to provide what are now regarded as acceptable standards of thermal comfort. In the UK as in a number of other countries, there is a real danger that responses in anticipation of global warming and climate change - including growing reliance on air-conditioning - will increase energy demand and CO{sub 2} emissions even further. This is an appropriate moment to reflect on the history and future of comfort, both as an idea and as a material reality. Based on interviews and discussions with UK policy makers and building practitioners involved in specifying and constructing what will become the indoor environments of the future, four possible scenarios are identified each with different implications for energy and resource consumption. By actively promoting debate about the indoor environment and associated ways of life, it may yet be possible to avoid becoming locked into social and technical trajectories that are ultimately unsustainable. The aim of this paper is to inspire and initiate just such a discussion through demonstrating that comfort is a highly negotiable socio-cultural construct. (author)

  2. Systematic assessment of environmental risk factors for bipolar disorder

    DEFF Research Database (Denmark)

    Bortolato, Beatrice; Köhler, Cristiano A.; Evangelou, Evangelos

    2017-01-01

    factors supported by high epidemiological credibility. Methods: We searched the Pubmed/MEDLINE, EMBASE and PsycInfo databases up to 7 October 2016 to identify systematic reviews and meta-analyses of observational studies that assessed associations between putative environmental risk factors and BD......Objectives: The pathophysiology of bipolar disorder is likely to involve both genetic and environmental risk factors. In our study, we aimed to perform a systematic search of environmental risk factors for BD. In addition, we assessed possible hints of bias in this literature, and identified risk...... met the inclusion criteria (seven meta-analyses and nine qualitative systematic reviews). Fifty-one unique environmental risk factors for BD were evaluated. Six meta-analyses investigated associations with a risk factor for BD. Only irritable bowel syndrome (IBS) emerged as a risk factor for BD...

  3. Assessment of external dose indoors in Lithuania

    International Nuclear Information System (INIS)

    Pilkyte, L.; Butkus, D.; Morkunas, G.

    2006-01-01

    The aim of this paper was an assessment of external exposure indoors and its dependence on construction materials and indoor radon concentrations in Lithuanian living houses. Relationship of absorbed dose rate in air indoors and activity indexes of the most commonly used construction materials (wood, concrete and bricks) have been studied using results received in measurements done in >4700 rooms in 1995-2005. Possible connections of dose rate indoors with indoor radon concentrations are also discussed. Findings of this study helped to make an assessment of the mean value of effective dose of Lithuanian population due to external exposure indoors which is equal to 0.58 mSv y -1 . The received data might also be used in improvement of quality of personal dosimetric measurements done in premises constructed of different construction materials. (authors)

  4. Indoor particle dynamics in a school office: determination of particle concentrations, deposition rates and penetration factors under naturally ventilated conditions.

    Science.gov (United States)

    Cong, X C; Zhao, J J; Jing, Z; Wang, Q G; Ni, P F

    2018-05-09

    Recently, the problem of indoor particulate matter pollution has received much attention. An increasing number of epidemiological studies show that the concentration of atmospheric particulate matter has a significant effect on human health, even at very low concentrations. Most of these investigations have relied upon outdoor particle concentrations as surrogates of human exposures. However, considering that the concentration distribution of the indoor particulate matter is largely dependent on the extent to which these particles penetrate the building and on the degree of suspension in the indoor air, human exposures to particles of outdoor origin may not be equal to outdoor particle concentration levels. Therefore, it is critical to understand the relationship between the particle concentrations found outdoors and those found in indoor micro-environments. In this study, experiments were conducted using a naturally ventilated office located in Qingdao, China. The indoor and outdoor particle concentrations were measured at the same time using an optical counter with four size ranges. The particle size distribution ranged from 0.3 to 2.5 μm, and the experimental period was from April to September, 2016. Based on the experimental data, the dynamic and mass balance model based on time was used to estimate the penetration rate and deposition rate at air exchange rates of 0.03-0.25 h -1 . The values of the penetration rate and deposition velocity of indoor particles were determined to range from 0.45 to 0.82 h -1 and 1.71 to 2.82 m/h, respectively. In addition, the particulate pollution exposure in the indoor environment was analyzed to estimate the exposure hazard from indoor particulate matter pollution, which is important for human exposure to particles and associated health effects. The conclusions from this study can serve to provide a better understanding the dynamics and behaviors of airborne particle entering into buildings. And they will also highlight

  5. Semivolatile organic compounds in indoor environments

    DEFF Research Database (Denmark)

    Weschler, Charles J.; Nazaroff, W.W.

    2008-01-01

    Semivolatile organic compounds (SVOCs) are ubiquitous in indoor environments, redistributing from their original sources to all indoor surfaces. Exposures resulting from their indoor presence contribute to detectable body burdens of diverse SVOCs, including pesticides, plasticizers, and flame ret...... remarkably well with levels measured in dermal hand wipes for SVOCs possessing a wide range of octanol-air partition coefficients....

  6. A Case Study of Indoor Garden-Based Learning with Hydroponics and Aquaponics: Evaluating Pro-Environmental Knowledge, Perception, and Behavior Change

    Science.gov (United States)

    Jon Schneller, Andrew; Schofield, Casey A.; Frank, Jenna; Hollister, Eliza; Mamuszka, Lauren

    2015-01-01

    This article reports on a mixed methods evaluation of an indoor garden-based learning curriculum for 5th and 6th graders which incorporated aquaponics and hydroponics technologies. This study provides a better understanding of the extent to which indoor gardening technologies can be used within the formal curriculum as an effective teaching tool.…

  7. A Semantic-Based Indexing for Indoor Moving Objects

    OpenAIRE

    Tingting Ben; Xiaolin Qin; Ning Wang

    2014-01-01

    The increasing availability of indoor positioning, driven by techniques like RFID, Bluetooth, and smart phones, enables a variety of indoor location-based services (LBSs). Efficient queries based on semantic-constraint in indoor spaces play an important role in supporting and boosting LBSs. However, the existing indoor index techniques cannot support these semantic constraints-based queries. To solve this problem, this paper addresses the challenge of indexing moving objects in indoor spaces,...

  8. Indoor Positioning using Wi-Fi

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun; Krarup, Mads Vering; Stisen, Allan

    The past decade has witnessed substantial research on methods for indoor Wi-Fi positioning. While much effort has gone into achieving high positioning accuracy and easing fingerprint collection, it is our contention that the general problem is not sufficiently well understood, thus preventing...... deployments and their usage by applications to become more widespread. Based on our own and published experiences on indoor Wi-Fi positioning deployments, we hypothesize the following: Current indoor Wi-Fi positioning systems and their utilization in applications are hampered by the lack of understanding...... of the requirements present in the real-world deployments. In this paper, we report findings from qualitatively studying organisational requirements for indoor Wi-Fi positioning. The studied cases and deployments cover both company and public-sector settings and the deployment and evaluation of several types...

  9. Adaptive Indoor Positioning Model Based on WLAN-Fingerprinting for Dynamic and Multi-Floor Environments

    Directory of Open Access Journals (Sweden)

    Iyad Husni Alshami

    2017-08-01

    Full Text Available The Global Positioning System demonstrates the significance of Location Based Services but it cannot be used indoors due to the lack of line of sight between satellites and receivers. Indoor Positioning Systems are needed to provide indoor Location Based Services. Wireless LAN fingerprints are one of the best choices for Indoor Positioning Systems because of their low cost, and high accuracy, however they have many drawbacks: creating radio maps is time consuming, the radio maps will become outdated with any environmental change, different mobile devices read the received signal strength (RSS differently, and peoples’ presence in LOS between access points and mobile device affects the RSS. This research proposes a new Adaptive Indoor Positioning System model (called DIPS based on: a dynamic radio map generator, RSS certainty technique and peoples’ presence effect integration for dynamic and multi-floor environments. Dynamic in our context refers to the effects of people and device heterogeneity. DIPS can achieve 98% and 92% positioning accuracy for floor and room positioning, and it achieves 1.2 m for point positioning error. RSS certainty enhanced the positioning accuracy for floor and room for different mobile devices by 11% and 9%. Then by considering the peoples’ presence effect, the error is reduced by 0.2 m. In comparison with other works, DIPS achieves better positioning without extra devices.

  10. Predictors of Indoor Radon Concentrations in Pennsylvania, 1989-2013.

    Science.gov (United States)

    Casey, Joan A; Ogburn, Elizabeth L; Rasmussen, Sara G; Irving, Jennifer K; Pollak, Jonathan; Locke, Paul A; Schwartz, Brian S

    2015-11-01

    Radon is the second-leading cause of lung cancer worldwide. Most indoor exposure occurs by diffusion of soil gas. Radon is also found in well water, natural gas, and ambient air. Pennsylvania has high indoor radon concentrations; buildings are often tested during real estate transactions, with results reported to the Department of Environmental Protection (PADEP). We evaluated predictors of indoor radon concentrations. Using first-floor and basement indoor radon results reported to the PADEP between 1987 and 2013, we evaluated associations of radon concentrations (natural log transformed) with geology, water source, building characteristics, season, weather, community socioeconomic status, community type, and unconventional natural gas development measures based on drilled and producing wells. Primary analysis included 866,735 first measurements by building, with the large majority from homes. The geologic rock layer on which the building sat was strongly associated with radon concentration (e.g., Axemann Formation, median = 365 Bq/m3, IQR = 167-679 vs. Stockton Formation, median = 93 Bq/m3, IQR = 52-178). In adjusted analysis, buildings using well water had 21% higher concentrations (β = 0.191, 95% CI: 0.184, 0.198). Buildings in cities (vs. townships) had lower concentrations (β = -0.323, 95% CI: -0.333, -0.314). When we included multiple tests per building, concentrations declined with repeated measurements over time. Between 2005 and 2013, 7,469 unconventional wells were drilled in Pennsylvania. Basement radon concentrations fluctuated between 1987 and 2003, but began an upward trend from 2004 to 2012 in all county categories (p Pennsylvania, 1989-2013. Environ Health Perspect 123:1130-1137; http://dx.doi.org/10.1289/ehp.1409014.

  11. Indoor Air Quality Manual.

    Science.gov (United States)

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  12. Indoor Climate of Large Glazed Spaces

    DEFF Research Database (Denmark)

    Hendriksen, Ole Juhl; Madsen, Christina E.; Heiselberg, Per

    In recent years large glazed spaces has found increased use both in connection with renovation of buildings and as part of new buildings. One of the objectives is to add an architectural element, which combines indoor- and outdoor climate. In order to obtain a satisfying indoor climate it is crui...... it is cruicial at the design stage to be able to predict the performance regarding thermal comfort and energy consumption. This paper focus on the practical implementation of Computational Fluid Dynamics (CFD) and the relation to other simulation tools regarding indoor climate.......In recent years large glazed spaces has found increased use both in connection with renovation of buildings and as part of new buildings. One of the objectives is to add an architectural element, which combines indoor- and outdoor climate. In order to obtain a satisfying indoor climate...

  13. Environmental and Lifestyle Factors Associated with Perceived Facial Age in Chinese Women

    Science.gov (United States)

    Mayes, Andrew E.; Murray, Peter G.; Gunn, David A.; Tomlin, Cyrena C.; Catt, Sharon D.; Wen, Yi B.; Zhou, Li P.; Wang, Hong Q.; Catt, Michael; Granger, Stewart P.

    2010-01-01

    Perceived facial age has been proposed as a biomarker of ageing with ‘looking young for one’s age' linked to physical and cognitive functioning and to increased survival for Caucasians. We have investigated the environmental and lifestyle factors associated with perceived facial ageing in Chinese women. Facial photographs were collected from 250 Chinese women, aged 25–70 years in Shanghai, China. Perceived facial age was determined and related to chronological age for each participant. Lifestyle and health information was collected by questionnaire. Bivariate analyses (controlling for chronological age) identified and quantified lifestyle variables associated with perceived facial age. Independent predictors of perceived age were identified by multivariate modelling. Factors which significantly associated with looking younger for one's chronological age included greater years of education (p<0.001), fewer household members (p = 0.027), menopausal status (p = 0.020), frequency of visiting one's doctor (p = 0.013), working indoors (p<0.001), spending less time in the sun (p = 0.015), moderate levels of physical activity (p = 0.004), higher frequency of teeth cleaning (p<0.001) and more frequent use of facial care products: cleanser (p<0.001); moisturiser (p = 0.016) or night cream (p = 0.016). Overall, 36.5% of the variation in the difference between perceived and chronological age could be explained by a combination of chronological age and 6 independent lifestyle variables. We have thus identified and quantified a number of factors associated with younger appearance in Chinese women. Presentation of these factors in the context of facial appearance could provide significant motivation for the adoption of a range of healthy behaviours at the level of both individuals and populations. PMID:21179450

  14. Endocrine disrupting chemicals in indoor and outdoor air

    Science.gov (United States)

    Rudel, Ruthann A.; Perovich, Laura J.

    The past 50 years have seen rapid development of new building materials, furnishings, and consumer products and a corresponding explosion in new chemicals in the built environment. While exposure levels are largely undocumented, they are likely to have increased as a wider variety of chemicals came into use, people began spending more time indoors, and air exchange rates decreased to improve energy efficiency. As a result of weak regulatory requirements for chemical safety testing, only limited toxicity data are available for these chemicals. Over the past 15 years, some chemical classes commonly used in building materials, furnishings, and consumer products have been shown to be endocrine disrupting chemicals - that is they interfere with the action of endogenous hormones. These include PCBs, used in electrical equipment, caulking, paints and surface coatings; chlorinated and brominated flame retardants, used in electronics, furniture, and textiles; pesticides, used to control insects, weeds, and other pests in agriculture, lawn maintenance, and the built environment; phthalates, used in vinyl, plastics, fragrances, and other products; alkylphenols, used in detergents, pesticide formulations, and polystyrene plastics; and parabens, used to preserve products like lotions and sunscreens. This paper summarizes reported indoor and outdoor air concentrations, chemical use and sources, and toxicity data for each of these chemical classes. While industrial and transportation-related pollutants have been shown to migrate indoors from outdoor sources, it is expected that indoor sources predominate for these consumer product chemicals; and some studies have identified indoor sources as the predominant factor influencing outdoor ambient air concentrations in densely populated areas. Mechanisms of action, adverse effects, and dose-response relationships for many of these chemicals are poorly understood and no systematic screening of common chemicals for endocrine disrupting

  15. Distribution of indoor radon concentrations and elements of a strategy for control

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1986-05-01

    Indoor radon concentrations vary widely in the US housing stock, with normal concentrations estimated to cause a significant risk of lung cancer by comparison with environmental exposures normally considered, and high concentrations causing risks that exceed even those from cigarette smoking. The probability distribution, i.e., the number of houses at various concentrations, can be estimated from an analysis of the US indoor radon data accumulated to date. Such an analysis suggests that in about a million houses, occupants are receiving exposures greater than those experienced by uranium miners. The form of the frequency distribution, including not only the average concentration, but also the number of houses with high levels, has substantial influence on strategies for control of indoor radon. Such strategies require three major elements: formulation of control objectives in terms of guidelines for remedial action and for new houses; selection of means for identifying homes with high concentrations; and a framework for deciding what types of control measures are appropriate to particular circumstances and how rapidly they should be employed

  16. Associations between the proportion of Salmonella seropositive slaughter pigs and the presence of herd level risk factors for introduction and transmission of Salmonella in 34 Danish organic, outdoor (non-organic) and indoor finishing-pig farms

    DEFF Research Database (Denmark)

    Zheng, D.M.; Bonde, Marianne; Sørensen, Jan Tind

    2007-01-01

    This paper evaluates the association between herd level risk factors for introduction and transmission of Salmonella in farms with three different production systems: organic, outdoor (non-organic) and indoor finishing-pig farms, and the presence of seropositive animals in the herds. Potential risk...... factors for Salmonella in the three pig production systems were identified through a literature review, and management information as well as serological data were collected in 34 pig farms: 11 organic farms, 12 outdoor farms, and 11 indoor farms. There were no general differences in the proportion...

  17. Critical role of environmental factors in the pathogenesis of psoriasis.

    Science.gov (United States)

    Zeng, Jinrong; Luo, Shuaihantian; Huang, Yumeng; Lu, Qianjin

    2017-08-01

    Psoriasis is a common cutaneous disease with multifactorial etiology including genetic and non-genetic factors, such as drugs, smoking, drinking, diet, infection and mental stress. Now, the role of the interaction between environmental factors and genetics are considered to be a main factor in the pathogenesis of psoriasis. However, it is a challenge to explore the mechanisms how the environmental factors break the body balance to affect the onset and development of psoriasis. In this article, we review the pathogenesis of psoriasis and summarize numerous clinical data to reveal the association between environmental factors and psoriasis. In addition, we focus on the mechanisms of environmental risk factors impact on psoriasis and provide a series of potential treatments against environmental risk factors. © 2017 Japanese Dermatological Association.

  18. Modeling indoor air pollution of outdoor origin in homes of SAPALDIA subjects in Switzerland.

    Science.gov (United States)

    Meier, Reto; Schindler, Christian; Eeftens, Marloes; Aguilera, Inmaculada; Ducret-Stich, Regina E; Ineichen, Alex; Davey, Mark; Phuleria, Harish C; Probst-Hensch, Nicole; Tsai, Ming-Yi; Künzli, Nino

    2015-09-01

    Given the shrinking spatial contrasts in outdoor air pollution in Switzerland and the trends toward tightly insulated buildings, the Swiss Cohort Study on Air Pollution and Lung and Heart Diseases in Adults (SAPALDIA) needs to understand to what extent outdoor air pollution remains a determinant for residential indoor exposure. The objectives of this paper are to identify determining factors for indoor air pollution concentrations of particulate matter (PM), ultrafine particles in the size range from 15 to 300nm, black smoke measured as light absorbance of PM (PMabsorbance) and nitrogen dioxide (NO2) and to develop predictive indoor models for SAPALDIA. Multivariable regression models were developed based on indoor and outdoor measurements among homes of selected SAPALDIA participants in three urban (Basel, Geneva, Lugano) and one rural region (Wald ZH) in Switzerland, various home characteristics and reported indoor sources such as cooking. Outdoor levels of air pollutants were important predictors for indoor air pollutants, except for the coarse particle fraction. The fractions of outdoor concentrations infiltrating indoors were between 30% and 66%, the highest one was observed for PMabsorbance. A modifying effect of open windows was found for NO2 and the ultrafine particle number concentration. Cooking was associated with increased particle and NO2 levels. This study shows that outdoor air pollution remains an important determinant of residential indoor air pollution in Switzerland. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Indoor exposure to environmental cigarette smoke, but not other inhaled particulates associates with respiratory symptoms and diminished lung function in adults

    DEFF Research Database (Denmark)

    Hersoug, Lars-Georg; Husemoen, Lise L N; Sigsgaard, Torben

    2010-01-01

    Exposure to particulate matter (PM) can induce airway inflammation and exacerbation of asthma. However, there is limited knowledge about the effects of exposure to indoor sources of PM. We investigated the associations between self-reported exposure to indoor sources of PM and lower airway sympto...

  20. VOC source identification from personal and residential indoor, outdoor and workplace microenvironment samples in EXPOLIS-Helsinki, Finland

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Rufus D. [KTL-Finnish National Inst. of Public Health, Dept. of Environmental Hygiene, Kuopio (Finland); California Univ., School of Public Health, Berkeley, CA (United States); Jurvelin, J. [KTL-Finnish National Inst. of Public Health, Dept. of Environmental Hygiene, Kuopio (Finland); Jyvaeskylae Polytechnic, School of Engineering and Technology, Jyvaeskylae (Finland); Koistinen, K. [KTL-Finnish National Inst. of Public Health, Dept. of Environmental Hygiene, Kuopio (Finland); Saarela, K. [VTT, Chemical Technology, Espoo (Finland); Jantunen, M. [EC JRC, Inst. of the Environment, Ispra (Italy)

    2001-07-01

    Principal component analyses (varimax rotation) were used to identify common sources of 30 target volatile organic compounds (VOCs) in residential outdoor, residential indoor and workplace microenvironment and personal 48-h exposure samples, as a component of the EXPOLIS-Helsinki study. Variability in VOC concentrations in residential outdoor microenvironments was dominated by compounds associated with long-range transport of pollutants, followed by traffic emissions, emissions from trees and product emissions. Variability in VOC concentrations in environmental tobacco smoke (ETS) free residential indoor environments was dominated by compounds associated with indoor cleaning products, followed by compounds associated with traffic emissions, long-range transport of pollutants and product emissions. Median indoor/outdoor ratios for compounds typically associated with traffic emissions and long-range transport of pollutants exceeded 1, in some cases quite considerably, indicating substantial indoor source contributions. Changes in the median indoor/outdoor ratios during different seasons reflected different seasonal ventilation patterns as increased ventilation led to dilution of those VOC compounds in the indoor environment that had indoor sources. Variability in workplace VOC concentrations was dominated by compounds associated with traffic emissions followed by product emissions, long-range transport and air fresheners. Variability in VOC concentrations in ETS free personal exposure samples was dominated by compounds associated with traffic emissions, followed by long-range transport, cleaning products and product emissions. VOC sources in personal exposure samples reflected the times spent in different microenvironments, and personal exposure samples were not adequately represented by any one microenvironment, demonstrating the need for personal exposure sampling. (Author)