WorldWideScience

Sample records for individual borehole monitoring

  1. Moisture monitoring in large diameter boreholes

    International Nuclear Information System (INIS)

    Tyler, S.

    1985-01-01

    The results of both laboratory and field experiments indicate that the neutron moisture gauge traditionally used in soil physics experiments can be extended for use in large diameter (up to 15 cm) steel-cased boreholes with excellent results. This application will permit existing saturated zone monitoring wells to be used for unsaturated zone monitoring of recharge, redistribution and leak detection from waste disposal facilities. Its applicability to large diameter cased wells also gives the soil physicist and ground-water hydrologist and new set of monitoring points in the unsaturated zone to study recharge and aquifer properties. 6 refs., 6 figs., 2 tabs

  2. Continuous monitoring of volcanoes with borehole strainmeters

    Science.gov (United States)

    Linde, Alan T.; Sacks, Selwyn

    Monitoring of volcanoes using various physical techniques has the potential to provide important information about the shape, size and location of the underlying magma bodies. Volcanoes erupt when the pressure in a magma chamber some kilometers below the surface overcomes the strength of the intervening rock, resulting in detectable deformations of the surrounding crust. Seismic activity may accompany and precede eruptions and, from the patterns of earthquake locations, inferences may be made about the location of magma and its movement. Ground deformation near volcanoes provides more direct evidence on these, but continuous monitoring of such deformation is necessary for all the important aspects of an eruption to be recorded. Sacks-Evertson borehole strainmeters have recorded strain changes associated with eruptions of Hekla, Iceland and Izu-Oshima, Japan. Those data have made possible well-constrained models of the geometry of the magma reservoirs and of the changes in their geometry during the eruption. The Hekla eruption produced clear changes in strain at the nearest instrument (15 km from the volcano) starting about 30 minutes before the surface breakout. The borehole instrument on Oshima showed an unequivocal increase in the amplitude of the solid earth tides beginning some years before the eruption. Deformational changes, detected by a borehole strainmeter and a very long baseline tiltmeter, and corresponding to the remote triggered seismicity at Long Valley, California in the several days immediately following the Landers earthquake are indicative of pressure changes in the magma body under Long Valley, raising the question of whether such transients are of more general importance in the eruption process. We extrapolate the experience with borehole strainmeters to estimate what could be learned from an installation of a small network of such instruments on Mauna Loa. Since the process of conduit formation from the magma sources in Mauna Loa and other

  3. Individual monitoring

    International Nuclear Information System (INIS)

    2004-01-01

    This Practical Radiation Technical Manual is one of a series which has been designed to provide guidance on radiological protection for employers, Radiation Protection Officers, managers and other technically competent persons who have a responsibility to ensure the safety of employees working with ionizing radiation. The Manual may be used together with the appropriate IAEA Practical Radiation Safety Manual to provide adequate training, instruction or information on individual monitoring for all employees engaged in work with ionizing radiations. Sources of ionizing radiation have a large number of applications in the workplace. The exposures of the individual workers involved may need to be routinely monitored and records kept of their cumulative radiation doses. There are also occasions when it is necessary to retrospectively determine a dose which may have been received by a worker. This Manual explains the basic terminology associated with individual monitoring and describes the principal types of dosimeters and other related techniques and their application in the workplace. The Manual will be of most benefit if it forms part of more comprehensive training or is supplemented by the advice of a qualified expert in radiation protection. Most of the dosimeters and techniques described in this Manual can only be provided by qualified experts

  4. Borehole radar for oil production monitoring

    NARCIS (Netherlands)

    Miorali, M.

    2012-01-01

    The area of smart well technology, or closed-loop reservoir management, aims at enhancing oil recovery through a combination of monitoring and control. Monitoring is performed with a wide range of sensors deployed downhole or at the surface. These sensors allow for capturing changes in the reservoir

  5. Simple, Affordable and Sustainable Borehole Observatories for Complex Monitoring Objectives

    Science.gov (United States)

    Kopf, A.; Hammerschmidt, S.; Davis, E.; Saffer, D.; Wheat, G.; LaBonte, A.; Meldrum, R.; Heesemann, M.; Villinger, H.; Freudenthal, T.; Ratmeyer, V.; Renken, J.; Bergenthal, M.; Wefer, G.

    2012-04-01

    Around 20 years ago, the scientific community started to use borehole observatories, so-called CORKs or Circulation Obviation Retrofit Kits, which are installed inside submarine boreholes, and which allow the re-establishment and monitoring of in situ conditions. From the first CORKs which allowed only rudimentary fluid pressure and temperature measurements, the instruments evolved to multi-functional and multi-level subseafloor laboratories, including, for example, long-term fluid sampling devices, in situ microbiological experiments or strainmeter. Nonetheless, most boreholes are still left uninstrumented, which is a major loss for the scientific community. In-stallation of CORKs usually requires a drillship and subsequent ROV assignments for data download and instru-ment maintenance, which is a major logistic and financial effort. Moreover, the increasing complexity of the CORK systems increased not only the expenses but led also to longer installation times and a higher sensitivity of the in-struments to environmental constraints. Here, we present three types of Mini-CORKs, which evolved back to more simple systems yet providing a wide range of possible in situ measurements. As a regional example the Nankai Trough is chosen, where repeated subduction thrust earthquakes with M8+ occurred. The area has been investigated by several drilling campaigns of the DSDP, ODP and IODP, where boreholes were already instrumented by different CORKs. Unfortunately, some of the more complex systems showed incomplete functionality, and moreover, the increased ship time forced IODP to rely on third party funds for the observatories. Consequently, the need for more affordable CORKs arose, which may be satisfied by the systems presented here. The first type, the so-called SmartPlug, provides two pressure transducers and four temperature sensors, and monitors a hydrostatic reference section and an isolated zone of interest. It was already installed at the Nankai Trough accretionary

  6. Multi-year monitoring of radon in boreholes at the Modra geophysical observatory, Slovakia

    International Nuclear Information System (INIS)

    Smetanova, I.; Steinitz, G.; Holy, K.

    2017-01-01

    Long-term radon monitoring was performed in two boreholes, at a depth of 13 m in the 40 m deep V-2 borehole (August 2003 September 2005), and at 3 m depth in the 10 m deep V-3 borehole (August 2003 April 2008). Diurnal, multi-day and annual variations in radon time-series were observed. Daily average of radon activity in V-2 borehole was significantly higher and ranged from 6.5 to 383.7 kBq/m 3 , while in V-3 borehole only between 1.2 and 139.4 kBq/m 3 . The seasonal pattern was more pronounced in V-3 time series, with the maximum occurring from October to March. Multi-day variations (2-10 days) were registered in V-2 and V-3 mostly simultaneously, with higher discrepancy in spring and summer periods, when radon activity in V-3 borehole was low. Diurnal radon variations with two maxima and two minima per day were registered in both boreholes. The influence of meteorological parameters on radon concentrations was investigated. The overall impression is that seasonal variation in radon in V-3 borehole seems to be connected with the temperature variation. Multi-day variations of radon in both boreholes coincided with the atmospheric pressure changes. An increase in radon activity was observed in V-3 borehole after the rainfall in spring and summer seasons. (authors)

  7. Computer modeling and laboratory experiments of a specific borehole to surface electrical monitoring technique (BSEMT)

    NARCIS (Netherlands)

    Meekes, J.A.C.; Zhang, X.; Abdul Fattah, R.

    2011-01-01

    Geophysical monitoring of the dynamical behavior of subsurface reservoirs (oil, gas, CO2) remains an important issue in geophysical research. A new idea for reservoir monitoring based on electrical resistivity tomography was developed at TNO. The essential element of the so-called BSEMT (Borehole to

  8. A Fiber-Optic Borehole Seismic Vector Sensor System for Geothermal Site Characterization and Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Paulsson, Bjorn N.P. [Paulsson, Inc., Van Nuys, CA (United States); Thornburg, Jon A. [Paulsson, Inc., Van Nuys, CA (United States); He, Ruiqing [Paulsson, Inc., Van Nuys, CA (United States)

    2015-04-21

    Seismic techniques are the dominant geophysical techniques for the characterization of subsurface structures and stratigraphy. The seismic techniques also dominate the monitoring and mapping of reservoir injection and production processes. Borehole seismology, of all the seismic techniques, despite its current shortcomings, has been shown to provide the highest resolution characterization and most precise monitoring results because it generates higher signal to noise ratio and higher frequency data than surface seismic techniques. The operational environments for borehole seismic instruments are however much more demanding than for surface seismic instruments making both the instruments and the installation much more expensive. The current state-of-the-art borehole seismic instruments have not been robust enough for long term monitoring compounding the problems with expensive instruments and installations. Furthermore, they have also not been able to record the large bandwidth data available in boreholes or having the sensitivity allowing them to record small high frequency micro seismic events with high vector fidelity. To reliably achieve high resolution characterization and long term monitoring of Enhanced Geothermal Systems (EGS) sites a new generation of borehole seismic instruments must therefore be developed and deployed. To address the critical site characterization and monitoring needs for EGS programs, US Department of Energy (DOE) funded Paulsson, Inc. in 2010 to develop a fiber optic based ultra-large bandwidth clamped borehole seismic vector array capable of deploying up to one thousand 3C sensor pods suitable for deployment into ultra-high temperature and high pressure boreholes. Tests of the fiber optic seismic vector sensors developed on the DOE funding have shown that the new borehole seismic sensor technology is capable of generating outstanding high vector fidelity data with extremely large bandwidth: 0.01 – 6,000 Hz. Field tests have shown

  9. Monitoring Plan for Fiscal Year 1999 Borehole Logging at 200 East Area Specific Retention Facilities

    International Nuclear Information System (INIS)

    Horton, D.G.

    1999-01-01

    The Hanford Groundwater Monitoring Project's vadose zone monitoring effort for fiscal year (FY) 1999 involves monitoring 30 boreholes for moisture content and gamma-ray emitting radionuclides. The boreholes are associated with specific retention trenches and cribs in the 200 East Area of the Hanford Site. The facilities to be monitored are the 216-A-2, -4, and -7 cribs, the 216-A-18 trench, the 216-B-14 through -19 cribs, the 216-B-20 through -34, -53A, and -58 trenches, the 216-B-35 through -42 trenches, and the 216-C-5 crib. This monitoring plan describes the facilities and the vadose zone at the cribs and trenches to be monitored; the field activities to be accomplished; the constituents of interest and the monitoring methods, including calibration issues; and the quality assurance and quality control requirements governing the monitoring effort. The results from the FY 1999 monitoring will show the current configuration of subsurface contamination and will be compared with past monitoring results to determine whether changes in contaminant distribution have occurred since the last monitoring effort

  10. Numerical Simulation of Borehole Flow in Deep Monitor Wells, Pearl Harbor Aquifer, Oahu, Hawaii

    Science.gov (United States)

    Rotzoll, K.; Oki, D. S.; El-Kadi, A. I.

    2010-12-01

    Salinity profiles collected from uncased deep monitor wells are commonly used to monitor freshwater-lens thickness in coastal aquifers. However, vertical flow in these wells can cause the measured salinity to differ from salinity in the adjacent aquifer. Substantial borehole flow has been observed in uncased wells in the Pearl Harbor aquifer, Oahu, Hawaii. A numerical modeling approach, incorporating aquifer hydraulic characteristics and recharge rates representative of the Pearl Harbor aquifer, was used to evaluate the effects of borehole flow on measured salinity profiles from deep monitor wells. Borehole flow caused by vertical hydraulic gradients associated with the natural regional groundwater-flow system and local groundwater withdrawals was simulated. Model results were used to estimate differences between vertical salinity profiles in deep monitor wells and the adjacent aquifer in areas of downward, horizontal, and upward flow within the regional flow system—for cases with and without nearby pumped wells. Aquifer heterogeneity, represented in the model as layers of contrasting permeability, was incorporated in model scenarios. Results from this study provide insight into the magnitude of the differences between vertical salinity profiles from deep monitor wells and the salinity distributions in the aquifers. These insights are relevant and are critically needed for management and predictive modeling purposes.

  11. Tidal modulation of temperature oscillations monitored in borehole Yaxcopoil-1 (Yucatán, Mexico)

    Czech Academy of Sciences Publication Activity Database

    Čermák, Vladimír; Bodri, L.; Šafanda, Jan

    2009-01-01

    Roč. 282, č. 1-4 (2009), s. 131-139 ISSN 0012-821X R&D Projects: GA AV ČR(CZ) IAA300120603; GA ČR(CZ) GA205/06/1181 Institutional research plan: CEZ:AV0Z30120515 Keywords : temperature monitoring * borehole convection * tidal forcing * recurrence quantification interval * (RQI) analysis * histograms cumulation technique Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 4.062, year: 2009

  12. Borehole Calibration Facilities to Support Gamma Logging for Hanford Subsurface Investigation and Contaminant Monitoring - 13516

    International Nuclear Information System (INIS)

    McCain, R.G.; Henwood, P.D.; Pope, A.D.; Pearson, A.W.

    2013-01-01

    Repeated gamma logging in cased holes represents a cost-effective means to monitor gamma-emitting contamination in the deep vadose zone over time. Careful calibration and standardization of gamma log results are required to track changes and to compare results over time from different detectors and logging systems. This paper provides a summary description of Hanford facilities currently available for calibration of logging equipment. Ideally, all logging organizations conducting borehole gamma measurements at the Hanford Site will take advantage of these facilities to produce standardized and comparable results. (authors)

  13. Borehole Calibration Facilities to Support Gamma Logging for Hanford Subsurface Investigation and Contaminant Monitoring - 13516

    Energy Technology Data Exchange (ETDEWEB)

    McCain, R.G.; Henwood, P.D.; Pope, A.D.; Pearson, A.W. [S M Stoller Corporation, 2439 Robertson Drive, Richland, WA 99354 (United States)

    2013-07-01

    Repeated gamma logging in cased holes represents a cost-effective means to monitor gamma-emitting contamination in the deep vadose zone over time. Careful calibration and standardization of gamma log results are required to track changes and to compare results over time from different detectors and logging systems. This paper provides a summary description of Hanford facilities currently available for calibration of logging equipment. Ideally, all logging organizations conducting borehole gamma measurements at the Hanford Site will take advantage of these facilities to produce standardized and comparable results. (authors)

  14. On the feasibility of borehole-to-surface electromagnetics for monitoring CO2 sequestration

    Science.gov (United States)

    Wilson, G. A.; Zhdanov, M. S.; Hibbs, A. D.; Black, N.; Gribenko, A. V.; Cuma, M.; Agundes, A.; Eiskamp, G.

    2012-12-01

    Carbon capture and storage (CCS) projects rely on storing supercritical CO2 in deep saline reservoirs where buoyancy forces drive the injected CO2 upward into the aquifer until a seal is reached. The permanence of the sequestration depends entirely on the long-term geological integrity of the seal. Active geophysical monitoring of the sequestration is critical for informing CO2 monitoring, accounting and verification (MVA) decisions. During injection, there exists a correlation between the changes in CO2 and water saturations in a saline reservoir. Dissolved salts react with the CO2 to precipitate out as carbonates, thereby generally decreasing the electrical resistivity. As a result, there is a correlation between the change in fluid saturation and measured electromagnetic (EM) fields. The challenge is to design an EM survey appropriate for monitoring large, deep reservoirs. Borehole-to-surface electromagnetic (BSEM) surveys consist of borehole-deployed galvanic transmitters and a surface-based array of electric and magnetic field sensors. During a recent field trial, it was demonstrated that BSEM could successfully identify the oil-water contact in the water-injection zone of a carbonate reservoir. We review the BSEM methodology, and perform full-field BSEM modeling. The 3D resistivity models used in this study are based on dynamic reservoir simulations of CO2 injection into a saline reservoir. Although the electric field response at the earth's surface is low, we demonstrate that it can be accurately measured and processed with novel methods of noise cancellation and sufficient stacking over the period of monitoring to increase the signal-to-noise ratio for subsequent seismic- and well-constrained 3D inversion. For long-term or permanent monitoring, we discuss the deployment of novel electric field sensors with chemically inert electrodes that couple to earth in a capacitive manner. This capacitive coupling is a purely EM phenomenon, which, to first order, has

  15. 10 CFR 835.402 - Individual monitoring.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Individual monitoring. 835.402 Section 835.402 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Monitoring of Individuals and Areas § 835.402 Individual monitoring. (a) For the purpose of monitoring individual exposures to external radiation...

  16. Muon borehole detector development for use in four-dimensional tomographic density monitoring

    Science.gov (United States)

    Flygare, Joshua

    The increase of CO2 concentrations in the atmosphere and the correlated temperature rise has initiated research into methods of carbon sequestration. One promising possibility is to store CO2 in subsurface reservoirs of porous rock. After injection, the monitoring of the injected CO2 is of paramount importance because the CO2 plume, if escaped, poses health and environmental risks. Traditionally, seismic reflection methods are the chosen method of determining changes in the reservoir density due to CO2 injection, but this is expensive and not continuous. A potential and promising alternative is to use cosmic muon tomography to determine density changes in the reservoir over a period of time. The work I have completed was the development of a muon detector that will be capable of being deployed in boreholes and perform long-term tomography of the reservoir of interest. The detector has the required dimensions, an angular resolution of approximately 2 degrees, and is robust enough to survive the caustic nature of the fluids in boreholes, as well as temperature and pressure fluctuations. The detector design is based on polystyrene scintillating rods arrayed in alternating layers. The layers, as arranged, can provide four-dimensional (4D) tomographic data to detect small changes in density at depths up to approximately 2 kilometers. Geant4, a Monte Carlo simulation code, was used to develop and optimize the detector design. Additionally, I developed a method of determining the muon flux at depth, including CO2 saturation changes in subsurface reservoirs. Preliminary experiments were performed at Pacific Northwest National Laboratory. This thesis will show the simulations I performed to determine the angular resolution and background discrimination required of the detector, the experiments to determine light transport through the polystyrene scintillating rods and fibers, and the method developed to predict muon flux changes at depth expected after injection.

  17. Results of geo-radio-monitoring for radioactive waste storage in large diameter boreholes in clayey ground

    International Nuclear Information System (INIS)

    Dmitriev, S.; Litinsky, Y.; Tkachenko, A.

    2010-01-01

    Document available in extended abstract form only. Full text of publication follows: The main purpose of the work carried out at the site of SUE MosSIA 'Radon' is to develop the system of geo-radio-monitoring for new type of storage facility (large diameter borehole) integrated into existing monitoring system of the whole site, check its effectiveness and improve the system, obtain initial results on safety aspects for using large diameter boreholes for RAW storage. Technology of large diameter boreholes (LDB) construction for low- and intermediate-level waste (LILW) isolation in moraine loams is being under development at SUE MosSIA 'Radon' site since the end of the last century. A project for construction of a demonstration unit for LILW storage in large diameter boreholes at the SUE MosSIA 'Radon' site in Sergiev Posad region has been developed taking into account specific site conditions. The main aim of the project is to develop the technology of LDB repository construction, operational procedures such as loading and retrieval, to develop and improve monitoring system for the new repository type, to get practical data on safety of radioactive wastes storage in new repositories, hermeticity of construction, and behavior of waste, waste packages, construction materials and near-field. In the case of LDB applications for LILW storage, the waste are removed from the scope of human activity into a stable geological medium. Waste are placed below the frost zone where damage of engineered barriers due to climatic factors is practically impossible. Two boreholes with 1.5 m internal diameter and 38 m depth have been drilled in 1997, equipped with engineering barriers including bentonite-concrete stone, licensed as storage facilities in 2003 and are in use now for solid and solidified RAW storage. Specific automated system of geo-radio-monitoring has been developed especially for the LDB-type repository, covering both the interior and the

  18. Reliability in individual monitoring service.

    Science.gov (United States)

    Mod Ali, N

    2011-03-01

    As a laboratory certified to ISO 9001:2008 and accredited to ISO/IEC 17025, the Secondary Standard Dosimetry Laboratory (SSDL)-Nuclear Malaysia has incorporated an overall comprehensive system for technical and quality management in promoting a reliable individual monitoring service (IMS). Faster identification and resolution of issues regarding dosemeter preparation and issuing of reports, personnel enhancement, improved customer satisfaction and overall efficiency of laboratory activities are all results of the implementation of an effective quality system. Review of these measures and responses to observed trends provide continuous improvement of the system. By having these mechanisms, reliability of the IMS can be assured in the promotion of safe behaviour at all levels of the workforce utilising ionising radiation facilities. Upgradation of in the reporting program through a web-based e-SSDL marks a major improvement in Nuclear Malaysia's IMS reliability on the whole. The system is a vital step in providing a user friendly and effective occupational exposure evaluation program in the country. It provides a higher level of confidence in the results generated for occupational dose monitoring of the IMS, thus, enhances the status of the radiation protection framework of the country.

  19. Individual monitoring dosimetry in Europe

    International Nuclear Information System (INIS)

    Menzel, H.G.

    1991-01-01

    This report discusses the various types of individual monitoring systems presently in use within the European community and neutron dosimetry research being coordinated by the EURADOS working group. Research is currently being conducted on nuclear track dosimeters, primarily with CR-39 (TM), and TLD-albedo dosimeters. Studies are being conducted on the energy and angular response of each type of dosimeter. Because the response of dosimeters depends on the energy of the neutrons, it is necessary to have spectral information to accurately assess the dose. Neutron energy spectrum measurements are being performed in typical work place environments. Work is also progressing on development of calibration sources which will be representative of the neutron energy spectrum found in typical neutron exposure situations. This work utilizes 14 MeV neutrons incident on a uranium block with various other filters. Research is also continuing on neutron dosimetry using tissue equivalent proportional counters and microdosimetric techniques. The results of intercomparisons between several different instruments are discussed. In addition to personnel dosimetry, these systems are being used to record the dose to passengers and flight crews aboard commercial aircraft

  20. Long term monitoring of water production flow rates in boreholes in the Callovo-Oxfordian argillaceous rock

    International Nuclear Information System (INIS)

    Vinsot, A.; Delay, J.; La Vaissiere, R. de; Cruchaudet, M.

    2010-01-01

    Document available in extended abstract form only. Water production was observed in several boreholes in the Callovo-Oxfordian argillaceous rock (COx). These boreholes were implemented in 2005 in the Andra's Underground Research Laboratory (URL) at more than 400 m in depth. Despite the low COx permeability: close to 10-13 m/s, two original experimental setups made it possible to monitor water production flow rates ranging from 0.5 to 50 mL/day during 3 to 4 years in 4 boreholes. This contribution describes the water flow rate evaluation methods and the results obtained from several experimental phases which may be considered as a series of constant pressure production tests. The first experimental concept was based on seepage water collection. It consisted in filling with gas the interval of an ascending borehole at a pressure close to 1 bar and closing it. The hydraulic pressure in the rock surrounding the sealed interval was higher than 30 bars. Due to the hydraulic pressure difference between the interval and the surrounding rock, the interstitial water of the formation flowed into the interval, accumulated at its base by gravity and was pumped out at a controlled flow rate. The pumping rate was adjusted so that the water level would not exceed 40 cm inside the 5-meter-long interval. The water level was deduced from the difference between two absolute pressure measurements: one above the water surface in the gas phase and the other at the bottom of the water column. The total volume of the daily produced formation water was obtained by adding the water volume pumped out during the day and the water volume difference inside the interval between the beginning and the end of the day. This kind of experiment was performed in two boreholes. The second experimental concept was based on water circulation. It consisted in filling with water the interval of a descending borehole. Two water circulation lines and one pressure control line linked the test interval to

  1. Site characterization and validation - monitoring of saline tracer transport by borehole radar measurements

    International Nuclear Information System (INIS)

    Olsson, O.; Andersson, P.; Gustafsson, E.

    1991-08-01

    The objective of this experiment was to map tracer transport in fractured crystalline rock through a combination of radar difference tomography and measurements of tracer concentration in boreholes and the validation drift. The experiment was performed twice, first the D-boreholes were used as a sink and then they were replaced by the validation drift and the experiment repeated. In both experiments saline tracer (200 ml/min, 2% salinity) was injected into fracture zone H about 25 m from the validation drift. The experiment revealed an inhomogeneous transmissivity distribution in Zone H. A significant portion of the tracer is transported upwards along Zone H and towards boreholes T1, T2, and W1. The breakthrough data from both experiments indicate that there are two major transport paths from borehole C2 to the D-boreholes/validation drift. One slow and diluted path to the bottom of the drift which carries the bulk of the mass and one fast path to the crown of the drift with high tracer concentration. The radar difference tomograms show that some tracer is lost through Zone S which intersects Zone H and is nearly perpendicular to it. The intersection between the two zones seems to constitute a preferred flow path. The breakthrough data and the radar difference tomograms have also been used to estimate flow porosity. The estimate obtained area of the same order approximately 10 -4 . (au) (28 refs.)

  2. Borehole logging

    International Nuclear Information System (INIS)

    Olsen, H.

    1995-01-01

    Numerous ground water investigations have been accomplished by means of borehole logging. Borehole logging can be applied to establish new water recovery wells, to control the existing water producing wells and source areas and to estimate ground water quality. (EG)

  3. Importance of borehole deviation surveys for monitoring of hydraulic fracturing treatments

    Czech Academy of Sciences Publication Activity Database

    Bulant, P.; Eisner, L.; Pšenčík, Ivan; Le Calvez, J. H.

    2007-01-01

    Roč. 55, č. 6 (2007), s. 891-899 ISSN 0016-8025 Grant - others:GA ČR(CZ) GA205/07/0032; EC(XE) MTKI-CT-2004-517242 Institutional research plan: CEZ:AV0Z30120515 Source of funding: R - rámcový projekt EK Keywords : hydraulic fracture * borehole deviation * seismic rays Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 0.731, year: 2007

  4. Monitoring for 99Tc in borehole waters using an extraction chromatographic resin

    International Nuclear Information System (INIS)

    Davis, T.M.; Nelson, D.M.; Thompson, E.G.

    1993-01-01

    A technique using an extraction chromatographic resin for the analysis of 99 Tc in borehole waters is presented. The method involves one pass of the sample through two resins, a rinse of the resins, then counting of one of the resins by liquid scintillation counting. The technique is intended to be used as a screening method of 99 Tc. The procedure employs commercially available materials, generates little waste and requires very little operator time

  5. Individual monitoring: A tool for active ALARA

    International Nuclear Information System (INIS)

    Hoefert, M.

    1989-01-01

    The system of individual monitoring at CERN is presented. Following the substantial decrease of individual doses over the last decade, emphasis is now placed on monitoring rather than on dosimetric aspects. Future developments have to face a possible decrease of dose limits that are difficult to control in view of the lower detection limits for the detectors presently used. One possible solution to the problem is the increase in the wearing time for individual dosemeters. (author)

  6. Monitoring and dose recording for the individual

    International Nuclear Information System (INIS)

    1988-01-01

    This document specifies the conditions under which monitoring of individuals is required. For workers identified as Atomic Radiation Workers, determination of dose or exposure must be made. In circumstances where personal monitoring techniques are impractical, doses and exposures may be estimated by non-personal monitoring techniques. For workers not identified as Atomic Radiation Workers, licensees must be able to demonstrate that there is no reasonable potential for accumulating radiation doses or exposures in excess of regulatory limits. (L.L.)

  7. Organization of the individual monitoring in Brazil

    International Nuclear Information System (INIS)

    Cunha, P.

    1991-01-01

    There are about 35,000 workers monitored in Brazil. Most of them are employed onhealth and non-nuclear industrial areas. The external individual monitoring is done by 10 laboratories accredited by the Brazilian Nuclear Energy Commission, CNEN, applying specific regulation. The personal date and doses of the monitored workers are stored in a data bank. In this paper, future improvements are also discussed. (orig.)

  8. Neutrons individual monitoring: 18 years of experience

    International Nuclear Information System (INIS)

    Goncalves, Sergio Alves; Mauricio, Claudia Lucia de Pinho; Moura Junior, Jose; Martins, Marcelo Marques; Meira, Nilton Ferreira; Diz, Ricardo; Seda, Rosangela Pinto Guimaraes

    2002-01-01

    The Thermoluminescent Dosimetry Laboratory of the Departamento de Monitoracao Individual of the Instituto de Radioprotecao e Dosimetria (LDT/DEMIN/IRD) is the only one in Brazil that operates routinely a whole body external individual monitoring service for neutrons. An albedo type monitor is used with thermoluminescent detectors pairs of 6 LiF:Mg,Ti and 7 LiF:Mg,Ti, made by Harshaw/Bicron and named, respectively, TLD-600 and TLD-700. In its 18 years of activities, the laboratory has ever made a great effort to be continuously updated. Equipment and procedures have been updated and optimized in order to guarantee the quality of all measurements. Nowadays, the neutron individual monitoring service evaluates doses of about 300 workers occupationally exposed to neutrons in several facilities of different areas of Brazil. The system history and the results obtained by the service in international intercomparisons and in its routine monitoring are presented in this work. (author)

  9. Borehole induction coil transmitter

    Science.gov (United States)

    Holladay, Gale; Wilt, Michael J.

    2002-01-01

    A borehole induction coil transmitter which is a part of a cross-borehole electromagnetic field system that is used for underground imaging applications. The transmitter consists of four major parts: 1) a wound ferrite or mu-metal core, 2) an array of tuning capacitors, 3) a current driver circuit board, and 4) a flux monitor. The core is wound with several hundred turns of wire and connected in series with the capacitor array, to produce a tuned coil. This tuned coil uses internal circuitry to generate sinusoidal signals that are transmitted through the earth to a receiver coil in another borehole. The transmitter can operate at frequencies from 1-200 kHz and supplies sufficient power to permit the field system to operate in boreholes separated by up to 400 meters.

  10. The Brazilian external individual monitoring scenario

    International Nuclear Information System (INIS)

    Mauricio, Claudia L.P.; Silva, Claudio R. da; Cunha, Paulo G. da

    2015-01-01

    In order to improve radiation protection it is necessary to have knowledge of the occupational radiation dose levels in all radiation facilities. This information comes from individual monitoring services, which are responsible for measuring and providing information about workers' radiation exposure. In 1981, the Comissao Nacional de Energia Nuclear (CNEN) of Brazil starts to develop a comprehensive system for regulation and storage of occupational radiation dose. This paper starts with an overview of the evolution of the Brazilian authorization and data storage system for external individual monitoring. It starts with a rule for authorization of all Brazilian photon individual monitoring services and the obligation for them to send the measured dose to CNEN. Up to now there is no regulation for neutron individual monitoring. The aim of this paper is to present the current scenario of the Brazilian external monitoring system, reinforcing its importance and remaining problems. The number of monitored workers greatly increases every year, having surpassed 150,000 people monitored. The stored data show that the mean annual occupational external dose is decreasing from 2.4 mSv in 1987 to about 0.6 mSv, in 2012, but there is still some not realistic very high dose measured (higher than 100 mSv), without investigation. About 80% of the annual dose values are lower than the monthly register level. As expected, the higher real photon doses are found in Nuclear Medicine, Industrial Radiology and Interventional Radiology. All recorded annual neutron dose values are lower than 20 mSv. (author)

  11. Estimation of groundwater flow from temperature monitoring in a borehole heat exchanger during a thermal response test

    Science.gov (United States)

    Yoshioka, Mayumi; Takakura, Shinichi; Uchida, Youhei

    2018-05-01

    To estimate the groundwater flow around a borehole heat exchanger (BHE), thermal properties of geological core samples were measured and a thermal response test (TRT) was performed in the Tsukuba upland, Japan. The thermal properties were measured at 57 points along a 50-m-long geological core, consisting predominantly of sand, silt, and clay, drilled near the BHE. In this TRT, the vertical temperature in the BHE was also monitored during and after the test. Results for the thermal properties of the core samples and from the monitoring indicated that groundwater flow enhanced thermal transfers, especially at shallow depths. The groundwater velocities around the BHE were estimated using a two-dimensional numerical model with monitoring data on temperature changes. According to the results, the estimated groundwater velocity was generally consistent with hydrogeological data from previous studies, except for the data collected at shallow depths consisting of a clay layer. The reasons for this discrepancy at shallow depths were predicted to be preferential flow and the occurrence of vertical flow through the BHE grout, induced by the hydrogeological conditions.

  12. Method and apparatus for monitoring fluid flow between a borehole and the surrounding formations in the course of drilling operations

    Energy Technology Data Exchange (ETDEWEB)

    Evans, J. L.; Gehrig, G. F.; Speers, J. M.

    1985-11-19

    A method and apparatus for establishing the rate at which fluid is transferred between a borehole and the surrounding formations in the course of moving drill string upward or downward in the borehole. A bell nipple is situated at the upper portion of the borehole. While tripping, drilling fluid is circulated into the borehole and exits through an outflow port in the bell nipple. The level of drilling fluid is maintained constant at the outflow port. Meters are provided to measure inflow and outflow rates. Circuitry is provided to establish the volume rate at which the amount of drill string within the borehole changes. The outputs of the meters and rate establishing means are summed to establish the compensated rate at which fluid is transferred between the formations and the borehole. This compensated rate is compared to an alarm limit. An alarm is activated if the compensated rate exceeds the alarm limit.

  13. Extremity individual monitoring: 30 years of experience

    International Nuclear Information System (INIS)

    Seda, Rosangela Pinto Guimaraes; Mauricio, Claudia Lucia de Pinho; Moura Junior, Jose; Martins, Marcelo Marques; Meira, Nilton Ferreira; Diz, Ricardo; Goncalves, Sergio Alves

    2002-01-01

    The Thermoluminescent Dosimetry Laboratory of the Departamento de Monitoracao Individual of the Instituto de Radioprotecao e Dosimetria (LDT/DEMIN/IRD) is one of the first extremity individual monitoring service in Brazil. In its 30 years of activities, the laboratory has ever made a great effort to be continuously updated. Equipment and procedures have been updated and optimized in order to guarantee the quality of all measurements. Nowadays, the extremity individual monitoring service evaluates monthly around 300 occupational doses in worker's hands of several Brazilian facilities in the fields of health, industry (including power reactor) and research. It is used a dosimetric ring with LiF:Mg,Ti thermoluminescent detectors (TLDs) from Harshaw/Bicron, named TLD-100. The Service helps the effective occupational control of the Brazilian works, which handle radioactive material or has their hands more exposed than the body. (author)

  14. Borehole Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Records of past temperature derived from boreholes drilled into the Earth crust. Parameter keywords describe what was measured in this data set. Additional summary...

  15. Results of 1999 Spectral Gamma-Ray and Neutron Moisture Monitoring of Boreholes at Specific Retention Facilities in the 200 East Area, Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    DG Horton; RR Randall

    2000-01-18

    Twenty-eight wells and boreholes in the 200 East Are% Hanford Site, Washington were monitored in 1999. The monitored facilities were past-practice liquid waste disposal facilities and consisted of six cribs and nineteen ''specific retention'' cribs and trenches. Monitoring consisted of spectral gamma-ray and neutron moisture logging. All data are included in Appendix B. The isotopes {sup 137}Cs, {sup 60}Co, {sup 235}U, {sup 238}U, and {sup 154}Eu were identified on spectral gamma logs from boreholes monitoring the PUREX specific retention facilities; the isotopes {sup 137}Cs, {sup 60}Co, {sup 125}Sb, and {sup 154}Eu were identified on the logs from boreholes at the BC Controlled Area cribs and trenches; and {sup 137}Cs, {sup 60}Co, and {sup 125}Sb were, identified on the logs from boreholes at the BX specific retention trenches. Three boreholes in the BC Controlled Area and one at the BX trenches had previous spectral gamma logs available for comparison with 1999 logs. Two of those logs showed that changes in the subsurface distribution of {sup 137}CS and/or {sup 60}Co had occurred since 1992. Although the changes are not great, they do point to continued movement of contaminants in the vadose zone. The logs obtained in 1999 create a larger baseline for comparison with future logs. Numerous historical gross gamma logs exist from most of the boreholes logged. Qualitative comparison of those logs with the 1999 logs show many substantial changes, most of which reflect the decay of deeper short-lived isotopes, such as {sup 106}Ru and {sup 125}Sb, and the much slower decay of shallower and longer-lived isotopes such as {sup 137}Cs. The radionuclides {sup 137}Cs and {sup 60}Co have moved in two boreholes since 1992. Given the amount of movement and the half-lives of the isotopes, it is expected that they will decay to insignificant amounts before reaching groundwater. However, gamma ray logging cannot detect many of the contaminants of interest such

  16. Results of 1998 spectral gamma-ray monitoring of boreholes at the 216-Z-1A tile field, 216-Z-9 trench, and 216-Z-12 crib

    International Nuclear Information System (INIS)

    Horton, D.G.; Randall, R.R.

    1998-09-01

    This document describes the results of fiscal year 1998 vadose zone monitoring of three inactive liquid waste disposal facilities associated with the Plutonium Finishing Plant: the 216-Z-1A tile field, the 216-Z-9 trench, and the 216-Z-12 crib. Monitoring consisted of spectral gamma-ray logging of 21 boreholes. This work was performed by Pacific Northwest National Laboratory in conjunction with Three Rivers Scientific and Waste management Federal Services, inc. Northwest Operations. These three liquid waste disposal facilities were chosen for monitoring because they were identified as containing some of the most significant sources of radioactive contamination in the Hanford Site vadose zone. The basic question addressed by this logging activity is ''Has the configuration of subsurface contamination changed since it was last measured?'' Previous borehole logging and laboratory analyses provide the baseline data to help answer this question

  17. Feasibility of borehole radar measurements to monitor water/steam fronts in EOR applications

    NARCIS (Netherlands)

    Miorali, M.; Slob, E.C.; Arts, R.J.

    2009-01-01

    A technique capable of capturing the dynamic of the reservoir fluids in the proximity of production wells would provide enormous benefit to the reservoir management; in fact, monitoring can be used to develop a feedback loop between measurements and control technologies to optimize the production.

  18. Flow and sorption controls of groundwater arsenic in individual boreholes from bedrock aquifers in central Maine, USA

    Science.gov (United States)

    Yang, Qiang; Culbertson, Charles W.; Nielsen, Martha G.; Schalk, Charles W.; Johnson, Carole D.; Marvinney, Robert G.; Stute, Martin; Zheng, Yan

    2014-01-01

    To understand the hydrogeochemical processes regulating well water arsenic (As) evolution in fractured bedrock aquifers, three domestic wells with [As] up to 478 μg/L are investigated in central Maine. Geophysical logging reveals that fractures near the borehole bottom contribute 70-100% of flow. Borehole and fracture water samples from various depths show significant proportions of As (up to 69%) and Fe (93-99%) in particulates (>0.45 μm). These particulates and those settled after a 16-day batch experiment contain 560-13,000 g/kg of As and 14-35% weight/weight of Fe. As/Fe ratios (2.5-20 mmol/mol) and As partitioning ratios (adsorbed/dissolved [As], 20,000-100,000 L/kg) suggest that As is sorbed onto amorphous hydrous ferric oxides. Newly drilled cores also show enrichment of As (up to 1300 mg/kg) sorbed onto secondary iron minerals on the fracture surfaces. Pumping at high flow rates induces large decreases in particulate As and Fe, a moderate increase in dissolved [As] and As(III)/As ratio, while little change in major ion chemistry. The δD and δ18O are similar for the borehole and fracture waters, suggesting a same source of recharge from atmospheric precipitation. Results support a conceptual model invoking flow and sorption controls on groundwater [As] in fractured bedrock aquifers whereby oxygen infiltration promotes the oxidation of As-bearing sulfides at shallower depths in the oxic portion of the flow path releasing As and Fe; followed by Fe oxidation to form Fe oxyhydroxide particulates, which are transported in fractures and sorb As along the flow path until intercepted by boreholes. In the anoxic portions of the flow path, reductive dissolution of As-sorbed iron particulates could re-mobilize As. For exposure assessment, we recommend sampling of groundwater without filtration to obtain total As concentration in groundwater.

  19. Intercomparison of radiation dosimeters for individual monitoring

    International Nuclear Information System (INIS)

    1993-05-01

    The Co-ordinated Research Programme on Intercomparison for Individual Monitoring was established to provide participants with an opportunity to assess (1) their ability to measure external photon radiation fields and (2) the potential impact of introduction of the new operational quantities on their dosimetry programmes. Twenty-four laboratories from 18 IAEA Member States and three international organizations, including the IAEA, participated. The results of phase II of the CRP are presented in this document, which includes a compilation of the presentations and conclusions from the meeting. Refs, figs and tabs

  20. Flow and sorption controls of groundwater arsenic in individual boreholes from bedrock aquifers in central Maine, USA

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Qiang [Lamont-Doherty Earth Observatory of Columbia University, 61 Route 9 W, Palisades, NY 10964 (United States); School of Earth and Environmental Sciences, Queens College and Graduate Center, City University of New York, 65-30 Kissena Blvd., Flushing, NY 11367 (United States); Culbertson, Charles W.; Nielsen, Martha G.; Schalk, Charles W. [U.S. Geological Survey, Maine Water Science Center, 196 Whitten Road, Augusta, ME 04330 (United States); Johnson, Carole D. [U.S. Geological Survey, Branch of Geophysics, 11 Sherman Place, Unit 5015, University of Connecticut, Storrs, CT 06269 (United States); Marvinney, Robert G. [Maine Geological Survey, 93 State House Station, Augusta, ME 04333 (United States); Stute, Martin [Lamont-Doherty Earth Observatory of Columbia University, 61 Route 9 W, Palisades, NY 10964 (United States); Zheng, Yan, E-mail: yan.zheng@qc.cuny.edu [Lamont-Doherty Earth Observatory of Columbia University, 61 Route 9 W, Palisades, NY 10964 (United States); School of Earth and Environmental Sciences, Queens College and Graduate Center, City University of New York, 65-30 Kissena Blvd., Flushing, NY 11367 (United States)

    2015-02-01

    To understand the hydrogeochemical processes regulating well water arsenic (As) evolution in fractured bedrock aquifers, three domestic wells with [As] up to 478 μg/L are investigated in central Maine. Geophysical logging reveals that fractures near the borehole bottom contribute 70–100% of flow. Borehole and fracture water samples from various depths show significant proportions of As (up to 69%) and Fe (93–99%) in particulates (> 0.45 μm). These particulates and those settled after a 16-day batch experiment contain 560–13,000 mg/kg of As and 14–35% weight/weight of Fe. As/Fe ratios (2.5–20 mmol/mol) and As partitioning ratios (adsorbed/dissolved [As], 20,000–100,000 L/kg) suggest that As is sorbed onto amorphous hydrous ferric oxides. Newly drilled cores also show enrichment of As (up to 1300 mg/kg) sorbed onto secondary iron minerals on the fracture surfaces. Pumping at high flow rates induces large decreases in particulate As and Fe, a moderate increase in dissolved [As] and As(III)/As ratio, while little change in major ion chemistry. The δD and δ{sup 18}O are similar for the borehole and fracture waters, suggesting a same source of recharge from atmospheric precipitation. Results support a conceptual model invoking flow and sorption controls on groundwater [As] in fractured bedrock aquifers whereby oxygen infiltration promotes the oxidation of As-bearing sulfides at shallower depths in the oxic portion of the flow path releasing As and Fe; followed by Fe oxidation to form Fe oxyhydroxide particulates, which are transported in fractures and sorb As along the flow path until intercepted by boreholes. In the anoxic portions of the flow path, reductive dissolution of As-sorbed iron particulates could re-mobilize As. For exposure assessment, we recommend sampling of groundwater without filtration to obtain total As concentration in groundwater. - Highlights: • Most Fe and some As exist as particulates in the tested borehole and fracture water.

  1. Borehole television survey

    International Nuclear Information System (INIS)

    Lau, J.S.O.

    1980-01-01

    The borehole television survey can provide a measure of the orientation, depth, width and aperture of any planar discontinuity intersected by a borehole and a technique is in an advanced stage of development by the Geological Survey of Canada (GSC) to make such measurements. Much of its practical application to date has been in crystalline rocks (plutons) at research areas pertaining to the Nuclear Waste Disposal Program in Canada. It also has many other engineering applications where bedrock stability is of particular concern. The equipment required to carry out the survey can be readily transported by two panel trucks with trailers. The components consist of a camera probe, control unit, cable storage reel, cable drive, video-tape recorder, TV monitor and two electrical generators. An inclined planar structure intersected by a borehole appears as an elliptical trace on the wall of the borehole. Such an intersection line shows on the TV monitor as a sinusoidal curve with a high point and a low point as the camera rotates through an angle of 360 degrees. The azimuth of the low point, measured by a compass in the camera probe, represents the direction of the dip of the planar structure. The angle of dip is measured midway between the high and low points or is computed from the maximum-to-minimum distance of the sinusoid and the hole diameter. These observations provide the true orientation of the planar structure if the borehole is vertical. However, if the borehole is inclined, direct observations will only provide the apparent orientation. The true orientation must thus be obtained either by means of stereographic projection or spherical trigonometry. A computer program has been written to calculate the true orientation from the apparent orientation. In the field, observation data are recorded directly on a data record sheet for keypunching and input into the computer

  2. Individual monitoring and dosimetry: The Goiania experience

    International Nuclear Information System (INIS)

    Lipsztein, J.L.; Melo, D.R.; Oliveira, C.A.N.; Bertelli, L.

    2000-01-01

    Several people were contaminated with 137 Cs in an accident involving the stealing and breaching of a radiotherapy source in Goiania, Brazil. A drug known as Prussian Blue was administered to some contaminated individuals to enhance Cs elimination from the body. Individuals internally contaminated were monitored for the two first months, exclusively by in vitro bioassay, i.e., urine and faeces analysis. After that period of time a field whole-body counter was set up in Goiania and individuals started to be monitored in vivo, on a regular basis. The total internal committed doses and the effect of Prussian blue treatment have been evaluated. For adults, the biological half-time (T 2 ) under PB treatment was reduced to an average value around to 31% of the half-time after finished treatment. For adolescents (T 2 ) was reduced to an average value around to 54% and for children was reduced to an average value around to 57%. A weight dependent biokinetic study of 137 Cs retention in humans was conducted. Data from 10 girls and 7 boys, aged 1 to 10 y old, as well as from 10 adolescents: 4 females and 6 males, and from 30 adults: 15 females and 15 males, contaminated in the accident, were used in this study. A planned experiment with beagle dogs were carried out to furnish some further data for our study. Based on these data, a three terms exponential equation is suggested to describe the 137 Cs retention in the body, the first-term associated with a very short half-time, the second with a longer half-time and the third term with a very long half-time, of the order of 400 to 570 days and relating to a retention fraction of only 0.1%. A table of weight, age and sex specific half-times for the second term is suggested. (author)

  3. Flow and sorption controls of groundwater arsenic in individual boreholes from bedrock aquifers in central Maine, USA.

    Science.gov (United States)

    Yang, Qiang; Culbertson, Charles W; Nielsen, Martha G; Schalk, Charles W; Johnson, Carole D; Marvinney, Robert G; Stute, Martin; Zheng, Yan

    2015-02-01

    To understand the hydrogeochemical processes regulating well water arsenic (As) evolution in fractured bedrock aquifers, three domestic wells with [As] up to 478 μg/L are investigated in central Maine. Geophysical logging reveals that fractures near the borehole bottom contribute 70-100% of flow. Borehole and fracture water samples from various depths show significant proportions of As (up to 69%) and Fe (93-99%) in particulates (>0.45 μm). These particulates and those settled after a 16-day batch experiment contain 560-13,000 mg/kg of As and 14-35% weight/weight of Fe. As/Fe ratios (2.5-20 mmol/mol) and As partitioning ratios (adsorbed/dissolved [As], 20,000-100,000 L/kg) suggest that As is sorbed onto amorphous hydrous ferric oxides. Newly drilled cores also show enrichment of As (up to 1300 mg/kg) sorbed onto secondary iron minerals on the fracture surfaces. Pumping at high flow rates induces large decreases in particulate As and Fe, a moderate increase in dissolved [As] and As(III)/As ratio, while little change in major ion chemistry. The δD and δ(18)O are similar for the borehole and fracture waters, suggesting a same source of recharge from atmospheric precipitation. Results support a conceptual model invoking flow and sorption controls on groundwater [As] in fractured bedrock aquifers whereby oxygen infiltration promotes the oxidation of As-bearing sulfides at shallower depths in the oxic portion of the flow path releasing As and Fe; followed by Fe oxidation to form Fe oxyhydroxide particulates, which are transported in fractures and sorb As along the flow path until intercepted by boreholes. In the anoxic portions of the flow path, reductive dissolution of As-sorbed iron particulates could re-mobilize As. For exposure assessment, we recommend sampling of groundwater without filtration to obtain total As concentration in groundwater. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Oskarshamn site investigation. Hydrogeochemical monitoring programme for core and percussion drilled boreholes 2009. Summary of ground water chemistry results from spring and autumn sampling

    Energy Technology Data Exchange (ETDEWEB)

    Regander, Claes; Bergman, Bo (Sweco Environment AB (Sweden))

    2010-09-15

    This report summarises the results obtained in 2009 from the hydrogeochemical monitoring programme for core and percussion drilled boreholes. During 2009 groundwater sampling has been performed in monitored (permanently installed) boreholes in two sampling periods, spring (May-June), and autumn (October-November). Both in spring and autumn groundwater sampling was carried out in the following 12 sections; HLX28:2, HLX35:2, HLX37:1, HLX39:1, KLX08:4, KLX10:2, KLX10:5, KLX12A:2, KLX15A:3, KLX15A:6, KLX18A:3, KLX19A:3. The programme started in 2005 and since then water sampling has been performed twice every year. The objective of the hydrogeochemical monitoring programme is to determine the groundwater composition in selected sections chosen for this purpose. In 2009 the sampling of core drilled borehole sections has been conducted in time series, where each borehole section has been sampled at seven occasions. Percussion drilled borehole sections has been sampled at three occasions. The final sample in each section was taken when the electric conductivity had reached a stable level. Obtained results from the activities presented here include groundwater chemistry data in accordance with SKB chemistry class 5 including options and SKB chemistry reduced class 5. SKB chemistry reduced class 5 includes analysis of pH, electric conductivity, alkalinity, density, drill water (uranine), major cations (Chapter 5.4), F-, Br-, Cl-, SO{sub 4}2-, Fe(II)/Fe(tot), HS-, DOC, TOC and the isotopes delta2H, delta18O and 3H. Options for SKB chemistry class 5 include even lanthanoids and other trace elements, As, In, I, environmental metals, NH{sub 4}+, nutrient salts and the isotopes delta34S, delta37Cl, 87Sr/86Sr, 10B/11B, delta13C, 226Ra, 222Rn, 238U, 234U, 230Th and 232Th. All data from the activity are stored in the SICADA database

  5. Monitoring plan for borehole logging at 216-Z-1A Tile Field, 216-Z-9 Trench, and 216-Z-12 Crib

    International Nuclear Information System (INIS)

    Horton, D.G.

    1998-04-01

    This plan describes the fiscal year 1998 vadose monitoring of three inactive, liquid waste disposal facilities associated with the Plutonium Finishing Plant (Z-Plant): the 216-Z-1A Tile Field, the 216-Z-9 Trench, and the 216-Z-12 Crib. Monitoring will consist of spectral gamma ray logging of 21 boreholes. This plan describes the physical characteristics of the facilities, their operational histories, the subsurface geology and known contamination distribution at each facility. The plan then describes the specific monitoring to be done including the boreholes to be logged, the methods of data acquisition, data reduction, and data evaluation, and finally, the quality control, data management and data reporting for this effort. The three liquid waste disposal facilities at the Z Plant were chosen to be monitored because they were identified as containing some of the most significant sources of radioactive contamination in the Hanford vadose zone. Johnson's analysis was based on the relative hazard obtained by combining curie quantities disposed to the facilities with appropriate health risk standards. The basic question to be addressed by this logging activity addresses the configuration of subsurface contamination since it was last measured. Historical data from the 216-Z-1A Tile Field, the 216-Z-9 Trench, and the 216-Z-12 Crib form the baseline for comparisons to answer this question

  6. The IAEA intercomparison for individual monitoring

    International Nuclear Information System (INIS)

    Griffith, R.V.; Boehm, J.; Herrman, D.; Strachotinsky, C.; Thompson, I.M.G.

    1990-01-01

    In 1985 the International Commission on Radiation Units and Measurements introduced a new set of operational quantities for radiation protection purposes through Report 39. The International Atomic Energy Agency has been concerned with the impact of possible adoption of these quantities by its 113 Member States. Thus the Agency implemented a Coordinated Research Programme on Intercomparison for Individual Monitoring in 1987. The first phase completed with a Research Coordination meeting of the participants in April, 1989. Photon exposures were provided at 11 energies over a range from 18 keV to 1.25 MeV at three standards laboratories in Austria, the GDR and the UK. Technical coordination was provided by the PTB, Braunschweig. Twenty one laboratories from 19 countries participated with film, TLD of various types, and combination dosemeters. Irradiations were performed on the IAEA 30 cm cubic, water-filled phantom that is in use throughout its network of 61 Secondary Standard Dosimetry Laboratories. Conversion coefficients for the IAEA phantom were calculated by the PTB and confirmed through measurements at ASMW in the GDR. Preliminary results indicated that the type of dosemeter (film or TLD) had little effect on the quality of results. The most important factor appears to be the specific techniques used for data interpretation. (author)

  7. Deep Borehole Field Test Laboratory and Borehole Testing Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, Kristopher L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brady, Patrick V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); MacKinnon, Robert J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Heath, Jason E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Herrick, Courtney G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jensen, Richard P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gardner, W. Payton [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sevougian, S. David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jang, Je-Hun [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stein, Emily R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bauer, Stephen J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Daley, Tom [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Freifeld, Barry M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Birkholzer, Jens [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Spane, Frank A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-19

    Deep Borehole Disposal (DBD) of high-level radioactive wastes has been considered an option for geological isolation for many years (Hess et al. 1957). Recent advances in drilling technology have decreased costs and increased reliability for large-diameter (i.e., ≥50 cm [19.7”]) boreholes to depths of several kilometers (Beswick 2008; Beswick et al. 2014). These advances have therefore also increased the feasibility of the DBD concept (Brady et al. 2009; Cornwall 2015), and the current field test design will demonstrate the DBD concept and these advances. The US Department of Energy (DOE) Strategy for the Management and Disposal of Used Nuclear Fuel and High-Level Radioactive Waste (DOE 2013) specifically recommended developing a research and development plan for DBD. DOE sought input or expression of interest from States, local communities, individuals, private groups, academia, or any other stakeholders willing to host a Deep Borehole Field Test (DBFT). The DBFT includes drilling two boreholes nominally 200m [656’] apart to approximately 5 km [16,400’] total depth, in a region where crystalline basement is expected to begin at less than 2 km depth [6,560’]. The characterization borehole (CB) is the smaller-diameter borehole (i.e., 21.6 cm [8.5”] diameter at total depth), and will be drilled first. The geologic, hydrogeologic, geochemical, geomechanical and thermal testing will take place in the CB. The field test borehole (FTB) is the larger-diameter borehole (i.e., 43.2 cm [17”] diameter at total depth). Surface handling and borehole emplacement of test package will be demonstrated using the FTB to evaluate engineering feasibility and safety of disposal operations (SNL 2016).

  8. Uncertainty analysis in the task of individual monitoring data

    International Nuclear Information System (INIS)

    Molokanov, A.; Badjin, V.; Gasteva, G.; Antipin, E.

    2003-01-01

    Assessment of internal doses is an essential component of individual monitoring programmes for workers and consists of two stages: individual monitoring measurements and interpretation of the monitoring data in terms of annual intake and/or annual internal dose. The overall uncertainty in assessed dose is a combination of the uncertainties in these stages. An algorithm and a computer code were developed for estimating the uncertainties in these stages. An algorithm and a computer code were developed for estimating the uncertainty in the assessment of internal dose in the task of individual monitoring data interpretation. Two main influencing factors are analysed in this paper: the unknown time of the exposure and variability of bioassay measurements. The aim of this analysis is to show that the algorithm is applicable in designing an individual monitoring programme for workers so as to guarantee that the individual dose calculated from individual monitoring measurements does not exceed a required limit with a certain confidence probability. (author)

  9. Quality Assurance in Individual Monitoring: 10 Years of Performance Monitoring of the TLD Based TNO Individual Monitoring Service (invited paper)

    International Nuclear Information System (INIS)

    Dijk, J.W.E. van

    1998-01-01

    The QA subscription forms the nucleus of the Quality Assurance (QA) programme of the TLD-based Individual Monitoring Service of TNO-CSD. This QA subscription is the subscription of a dummy customer to the service. As this customer is treated exactly like a normal customer, all aspects of the service are monitored by the QA subscription. An overview is given of 10 years of monitoring the performance of the service. Various improvements over the past decade have resulted in a standard deviation in a low dose measurement of 0.01 mSv and a relative standard deviation at higher doses of 5%. These figures represent the performance under routine circumstances and thus include variations due to variations in the natural background from place to place and, for example, due to transport. (author)

  10. Quality Assurance in Individual Monitoring: 10 Years of Performance Monitoring of the TLD Based TNO Individual Monitoring Service (invited paper)

    Energy Technology Data Exchange (ETDEWEB)

    Dijk, J.W.E. van

    1998-07-01

    The QA subscription forms the nucleus of the Quality Assurance (QA) programme of the TLD-based Individual Monitoring Service of TNO-CSD. This QA subscription is the subscription of a dummy customer to the service. As this customer is treated exactly like a normal customer, all aspects of the service are monitored by the QA subscription. An overview is given of 10 years of monitoring the performance of the service. Various improvements over the past decade have resulted in a standard deviation in a low dose measurement of 0.01 mSv and a relative standard deviation at higher doses of 5%. These figures represent the performance under routine circumstances and thus include variations due to variations in the natural background from place to place and, for example, due to transport. (author)

  11. Application of the ALARA principle to individual occupational radiation monitoring

    International Nuclear Information System (INIS)

    Aleinikov, V.E.

    1998-01-01

    Routine individual occupational radiation monitoring is necessary to ensure that exposure are kept as low as reasonably achievable (ALARA) and that the authorized dose limits are not exceeded. The type and extend of the monitoring depend on the nature and magnitude of occupational radiation exposure. Optimal choice of the wearing time for individual dosimeters, T, has important consequences for achievement of the individual monitoring objects. The choice of T depends on individual dose distribution, the lower detection limit for the detector used, the lost of an information during period of monitoring, the cost of the measurements and the benefits associated with the results. The paper describes the application of quantitative optimization techniques to optimize the wearing time for individual dosimeters. It was shown how optimal wearing time for individual dosimeters depends on dose distribution, the lower detection limit, dose limit, fading and cost of the measurements. (author)

  12. Individual monitoring in high-energy stray radiation fields

    International Nuclear Information System (INIS)

    Hoefert, M.; Stevenson, G.R.

    1995-01-01

    Due to the lack of passive or active devices that could be considered as personal dosemeters in high-energy stray fields one can at present only perform individual monitoring around high energy accelerators. Of all detectors currently available it is shown that the NTA film is the most suitable method for individually monitoring the neutron exposure of more than 3000 persons regularly, reliably, and cost effectively like at CERN. (author)

  13. Monitoring of Individual Needs in Diabetes (MIND)-2

    DEFF Research Database (Denmark)

    Snoek, Frank J; Kersch, Nancy Y A; Eldrup, Ebbe

    2012-01-01

    To test the effects of implementing computer-assisted Monitoring of Individual Needs in Diabetes (MIND) in routine diabetes care on psychological status and glycemic control, identify predictors of poor psychological outcomes, and evaluate care providers' experiences.......To test the effects of implementing computer-assisted Monitoring of Individual Needs in Diabetes (MIND) in routine diabetes care on psychological status and glycemic control, identify predictors of poor psychological outcomes, and evaluate care providers' experiences....

  14. Radiation borehole logging method

    International Nuclear Information System (INIS)

    Wylie, A.; Mathew, P.J.

    1977-01-01

    A method of obtaining an indication of the diameter of a borehole is described. The method comprises subjecting the walls of the borehole to monoenergetic gamma radiation and making measurements of the intensity of gamma radiation backscattered from the walls. The energy of the radiation is sufficiently high for the shape to be substantially independent of the density and composition of the borehole walls

  15. International conference on individual monitoring of ionising radiation

    International Nuclear Information System (INIS)

    Vanhavere, Filip

    2016-01-01

    This special issue of the journal Radiation Protection Dosimetry is dedicated to the Proceedings of the International Conference on Individual Monitoring of Ionising Radiation (IM2015), which is the fifth of a series of conferences dealing with individual monitoring. This conference series is initiated by EURADOS, the European Radiation Dosimetry Group, and is organised every 5 years. In 2015, the conference was jointly organised by the Belgian Nuclear Research Centre (SCK.CEN), AV Controlatom, and the Vrije Universiteit Brussel. It brought together scientists from regulatory authorities, individual monitoring services (IMS), research bodies, European networks and companies, for the purpose of facilitating the dissemination of knowledge, exchanging experiences and promoting new ideas in the field of individual monitoring. After the conference, 124 papers were submitted for publication in these peer-reviewed proceedings. From these, 103 were finally accepted for publication. The help of the numerous referees and the guest editors is very much appreciated. These proceedings provide a full image of the IM2015 conference. The high-level publications will be useful to improve the state of individual monitoring all over the world and aim to inspire many scientists to continue their work on a better monitoring of radiologically exposed workers

  16. Performance analysis of the TNO TLD individual monitoring service

    International Nuclear Information System (INIS)

    Dijk, J.W.E. van; Julius, H.W.

    1990-01-01

    The purpose of this study was to analyse the performance and to establish the lowest detectable occupational dose (LDOD) of the TNO TL dosemeter, in use for large scale routine individual monitoring since 1983. The TNO individual monitoring service uses three TLD reader systems and over 45000 TL dosemeters, designed to measure H s (0.07) and H p (10). Each reader system is normalised daily and each individual dosemeter is calibrated every ten readout cycles. The performance of the service is monitored by a double blind experimental set-up. A series of 10 routine dosemeters is issued every fortnight, mailed, exposed by staff not involved in the monitoring service, sent back and evaluated. The conclusion of this study is that the lowest detectable occupational dose is less than 0.04 mSv and that the integrated dose at the level of the annual dose limit is measured within 2%. (author)

  17. Implementation of standards for individual monitoring in Europe

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Alves, J. G.; Ambrosi, P.; Janzekovic, H.; Vartiainen, E.

    2004-01-01

    A large number of standards are available for radiation protection and individual monitoring purposes. They are published by various organisations, international and national. Moreover, the increasing policy of 'Quality' applied to individual monitoring requires the implementation of standards on Quality Assurance (QA) both in technical and management aspects of a dosimetric service. Implementation of standards is not mandatory; therefore, varying degrees of implementation can be found in different European countries. However, for a number of good reasons, a degree of harmonisation within the European Union (EU) of the requirements and procedures for individual monitoring would be desirable. Harmonisation as applied to dosimetric services does not mean that they should all follow exactly the same procedures, but that they should aim to meet the same general requirements, and their results should be comparable. This article aims to compile information on the use of all standards applied within individual monitoring practices, be it on the calibration of dosemeters or on the QA procedures to be applied to the overall dose evaluation process. Both 'technical standards' and 'quality standards' will be discussed. A list of documents of relevance to subjects such as recommendations and requirements in the field of individual monitoring, whose application could help in the harmonisation of procedures, will also be given. As it is agreed that implementation of quality standards is a relevant framework within which harmonisation can be achieved, guidance on the implementation of quality standards in a dosimetric service is given. Accreditation and approval of dosimetric services will be of relevance in the process of harmonisation of individual monitoring within the EU. In this article, a discussion of various procedures and the meaning of both forms of recognition is also provided. Although most of the text applies to the monitoring of internal and external exposure to

  18. Borehole Muon Detector Development

    Science.gov (United States)

    Bonneville, A.; Flygare, J.; Kouzes, R.; Lintereur, A.; Yamaoka, J. A. K.; Varner, G. S.

    2015-12-01

    Increasing atmospheric CO2 concentrations have spurred investigation into carbon sequestration methods. One of the possibilities being considered, storing super-critical CO2 in underground reservoirs, has drawn more attention and pilot projects are being supported worldwide. Monitoring of the post-injection fate of CO2 is of utmost importance. Generally, monitoring options are active methods, such as 4D seismic reflection or pressure measurements in monitoring wells. We propose here to develop a 4-D density tomography of subsurface CO2 reservoirs using cosmic-ray muon detectors deployed in a borehole. Muon detection is a relatively mature field of particle physics and there are many muon detector designs, though most are quite large and not designed for subsurface measurements. The primary technical challenge preventing deployment of this technology in the subsurface is the lack of miniaturized muon-tracking detectors capable of fitting in standard boreholes and that will resist the harsh underground conditions. A detector with these capabilities is being developed by a collaboration supported by the U.S. Department of Energy. Current simulations based on a Monte Carlo modeling code predict that the incoming muon angle can be resolved with an error of approximately two degrees, using either underground or sea level spectra. The robustness of the design comes primarily from the use of scintillating rods as opposed to drift tubes. The rods are arrayed in alternating layers to provide a coordinate scheme. Preliminary testing and measurements are currently being performed to test and enhance the performance of the scintillating rods, in both a laboratory and a shallow underground facility. The simulation predictions and data from the experiments will be presented.

  19. Internal quality control program for individual monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Mauricio, Claudia L.P.; Moura Junior, Jose; Patrao, Karla C.S. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)]. E-mail: claudia@ird.gov.br; moura@ird.gov.br; karla@ird.gov.br

    2007-07-01

    With a focus on continuous improvement, since 2002, a special internal procedure for following and checking the performance of our individual monitoring services has been implemented. A fictitious installation, named 'Fantasma' has been created, initially, with 4 film badges and 7 thermoluminescent dosimetric ring users. Since 2005, this quality control program includes also the albedo neutron individual monitoring service. Monthly, the 'Fantasma' test monitors are irradiated by traceable Cs-137 and Am-Be sources. The calibration quantities are: the photon dose equivalent (H{sub x}) for the photographic individual monitor, the maximum dose equivalent (MADE) for the albedo neutron individual monitor and the personal dose equivalent at 0.07 mm depth (H{sub p}(0.07)) for ring monitor. Up to now, all results show compliance with the specific trumpet curves acceptance limits. Once, a small sub-evaluation tendency has been noted and this information was used to improve the film system. For the photographic film system, the evaluated value to reference dose ratios range from 0.71 to 1.12, with a mean value of 0.91 {+-} 0.12. For the ring system, the ratio ranges from 0.69 to 1.40, with a mean value of 1.02 {+-} 0.07. For the neutron system, which presents intrinsic larger uncertainties, the ratio ranged from 0.67 to 1.88, with mean value of 1.16 {+-} 0.27. (author)

  20. Individual monitoring program for occupational exposures to radionuclides by inhalation

    International Nuclear Information System (INIS)

    Piechowski, J.; Menoux, B.

    1985-01-01

    Individual monitoring of exposure to radioactive products is carried out when there is a risk of significant internal contamination. In its publications 26 and 35 the International Commission on Radiological Protection has given recommendations on the monitoring programs. Besides, the metabolic models developed in publication 30 have allowed to establish retention and excretion functions for some radionuclides after intake by inhalation in the adult man. These have been published in the report CEA-R--5266. Considering these data and taking into account the practical problems that occur in the course of surveillance of workers, programs of individual monitoring for contamination by inhalation are proposed. These programs for routine and special monitoring have been developed for the most common radionuclides involved in the nuclear industry [fr

  1. Deep Borehole Field Test Research Activities at LBNL

    Energy Technology Data Exchange (ETDEWEB)

    Dobson, Patrick [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Tsang, Chin-Fu [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kneafsey, Timothy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Borglin, Sharon [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Piceno, Yvette [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Andersen, Gary [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Nakagawa, Seiji [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Nihei, Kurt [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rutqvist, Jonny [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Doughty, Christine [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Reagan, Matthew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-19

    The goal of the U.S. Department of Energy Used Fuel Disposition’s (UFD) Deep Borehole Field Test is to drill two 5 km large-diameter boreholes: a characterization borehole with a bottom-hole diameter of 8.5 inches and a field test borehole with a bottom-hole diameter of 17 inches. These boreholes will be used to demonstrate the ability to drill such holes in crystalline rocks, effectively characterize the bedrock repository system using geophysical, geochemical, and hydrological techniques, and emplace and retrieve test waste packages. These studies will be used to test the deep borehole disposal concept, which requires a hydrologically isolated environment characterized by low permeability, stable fluid density, reducing fluid chemistry conditions, and an effective borehole seal. During FY16, Lawrence Berkeley National Laboratory scientists conducted a number of research studies to support the UFD Deep Borehole Field Test effort. This work included providing supporting data for the Los Alamos National Laboratory geologic framework model for the proposed deep borehole site, conducting an analog study using an extensive suite of geoscience data and samples from a deep (2.5 km) research borehole in Sweden, conducting laboratory experiments and coupled process modeling related to borehole seals, and developing a suite of potential techniques that could be applied to the characterization and monitoring of the deep borehole environment. The results of these studies are presented in this report.

  2. Deep Borehole Field Test Research Activities at LBNL

    International Nuclear Information System (INIS)

    Dobson, Patrick; Tsang, Chin-Fu; Kneafsey, Timothy; Borglin, Sharon; Piceno, Yvette; Andersen, Gary; Nakagawa, Seiji; Nihei, Kurt; Rutqvist, Jonny; Doughty, Christine; Reagan, Matthew

    2016-01-01

    The goal of the U.S. Department of Energy Used Fuel Disposition's (UFD) Deep Borehole Field Test is to drill two 5 km large-diameter boreholes: a characterization borehole with a bottom-hole diameter of 8.5 inches and a field test borehole with a bottom-hole diameter of 17 inches. These boreholes will be used to demonstrate the ability to drill such holes in crystalline rocks, effectively characterize the bedrock repository system using geophysical, geochemical, and hydrological techniques, and emplace and retrieve test waste packages. These studies will be used to test the deep borehole disposal concept, which requires a hydrologically isolated environment characterized by low permeability, stable fluid density, reducing fluid chemistry conditions, and an effective borehole seal. During FY16, Lawrence Berkeley National Laboratory scientists conducted a number of research studies to support the UFD Deep Borehole Field Test effort. This work included providing supporting data for the Los Alamos National Laboratory geologic framework model for the proposed deep borehole site, conducting an analog study using an extensive suite of geoscience data and samples from a deep (2.5 km) research borehole in Sweden, conducting laboratory experiments and coupled process modeling related to borehole seals, and developing a suite of potential techniques that could be applied to the characterization and monitoring of the deep borehole environment. The results of these studies are presented in this report.

  3. Monitoring individual and joint action outcomes in duet music performance

    DEFF Research Database (Denmark)

    Loehr, Janeen; Kourtis, Dimitrios; Vesper, Cordula

    2013-01-01

    We investigated whether people monitor the outcomes of their own and their partners’ individual actions as well as the outcome of their combined actions when performing joint actions together. Pairs of pianists memorized both parts of a piano duet. Each pianist then performed one part while their...

  4. An optimization procedure for borehole emplacement in fractured media

    International Nuclear Information System (INIS)

    Billaux, D.; Guerin, F.

    1998-01-01

    Specifying the position and orientation of the 'next borehole(s)' in a fractured medium, from prior incomplete knowledge of the fracture field and depending on the objectives assigned to this new borehole(s), is a crucial point in the iterative process of site characterization. The work described here explicitly includes site knowledge and specific objectives in a tractable procedure that checks possible borehole characteristics, and rates all trial boreholes according to their compliance with objectives. The procedure is based on the following ideas : Firstly, the optimization problem is strongly constrained, since feasible borehole head locations and borehole dips are generally limited. Secondly, a borehole is an 'access point' to the fracture network. Finally, when performing a flow or tracer test, the information obtained through the monitoring system will be best if this system detects the largest possible share of the flow induced by the test, and if it cuts the most 'interesting' flow paths. The optimization is carried out in four steps. 1) All possible borehole configurations are defined and stored. Typically, several hundred possible boreholes are created. Existing boreholes are also specified. 2) Stochastic fracture networks reproducing known site characteristics are generated. 3) A purely geometrical rating of all boreholes is used to select the 'geometrically best' boreholes or groups of boreholes. 4) Among the boreholes selected by the geometrical rating, the best one(s) is chosen by simulating the experiment for which it will be used and checking flowrates through possible boreholes. This method is applied to study the emplacement of a set of five monitoring boreholes prior to the sinking of a shaft for a planned underground laboratory in a granite massif in France (Vienne site). Twelve geometrical parameters are considered for each possible borehole. A detailed statistical study helps decide on the shape of a minimization function. This is then used

  5. Individual Monitoring service for occupational exposure in Sudan

    International Nuclear Information System (INIS)

    Suliman, E.E.; Shaddad, I.; Medani, B.E.; Osman, M.Y.

    2005-01-01

    Full text: Individual Monitoring Service (IMS) is a dosimetry service provided by Radiation Protection Department (RPD) of Sudan Atomic Energy Commission (SAEC) to monitor about 400 occupational exposed workers all over the country. Measurements were done using thermoluminescence dosimeters (TLD). The calibration of the TLD system was performed on a phantom with application of suitable correction factors in the SSDL using Cs-137 and different qualities of x-ray energies. Personal dose equivalents Hp(10) and Hp(0.07) were evaluated by employing one individual dosimeter to be carried continuously by the occupational exposed person while at work. In this work the dose received by workers in x-ray diagnostic radiology, radiotherapy, nuclear medicine, research and industrial radiography were evaluated. Radiation doses for the years 1999, 2000, 2001, 2002 and 2003 were compared. From the results obtained, it was noticed that individual monitoring service had expanded over the last years. The average individual annual dose in different applications is less than 1 mSv/y except for the workers in industrial radiography, only 12 radiation workers (3.64 %) received doses exceeding 1 mSv and no individual approached the dose limit of 20 mSv recommended by the ICRP and set by Sudan's regulations. (author)

  6. Monitoring individual tree-based change with airborne lidar.

    Science.gov (United States)

    Duncanson, Laura; Dubayah, Ralph

    2018-05-01

    Understanding the carbon flux of forests is critical for constraining the global carbon cycle and managing forests to mitigate climate change. Monitoring forest growth and mortality rates is critical to this effort, but has been limited in the past, with estimates relying primarily on field surveys. Advances in remote sensing enable the potential to monitor tree growth and mortality across landscapes. This work presents an approach to measure tree growth and loss using multidate lidar campaigns in a high-biomass forest in California, USA. Individual tree crowns were delineated in 2008 and again in 2013 using a 3D crown segmentation algorithm, with derived heights and crown radii extracted and used to estimate individual tree aboveground biomass. Tree growth, loss, and aboveground biomass were analyzed with respect to tree height and crown radius. Both tree growth and loss rates decrease with increasing tree height, following the expectation that trees slow in growth rate as they age. Additionally, our aboveground biomass analysis suggests that, while the system is a net source of aboveground carbon, these carbon dynamics are governed by size class with the largest sources coming from the loss of a relatively small number of large individuals. This study demonstrates that monitoring individual tree-based growth and loss can be conducted with multidate airborne lidar, but these methods remain relatively immature. Disparities between lidar acquisitions were particularly difficult to overcome and decreased the sample of trees analyzed for growth rate in this study to 21% of the full number of delineated crowns. However, this study illuminates the potential of airborne remote sensing for ecologically meaningful forest monitoring at an individual tree level. As methods continue to improve, airborne multidate lidar will enable a richer understanding of the drivers of tree growth, loss, and aboveground carbon flux.

  7. Electromagnetic fields in cased borehole

    International Nuclear Information System (INIS)

    Lee, Ki Ha; Kim, Hee Joon; Uchida, Toshihiro

    2001-01-01

    Borehole electromagnetic (EM) measurements, using fiberglass-cased boreholes, have proven useful in oil field reservoir characterization and process monitoring (Wilt et al., 1995). It has been presumed that these measurements would be impossible in steel-cased wells due to the very large EM attenuation and phase shifts. Recent laboratory and field studies have indicated that detection of EM signals through steel casing should be possible at low frequencies, and that these data provide a reasonable conductivity image at a useful scale. Thus, we see an increased application of this technique to mature oilfields, and an immediate extension to geothermal industry as well. Along with the field experiments numerical model studies have been carried out for analyzing the effect of steel casing to the EM fields. The model used to be an infinitely long uniform casing embedded in a homogeneous whole space. Nevertheless, the results indicated that the formation signal could be accurately recovered if the casing characteristics were independently known (Becker et al., 1998; Lee el al., 1998). Real steel-cased wells are much more complex than the simple laboratory models used in work to date. The purpose of this study is to develop efficient numerical methods for analyzing EM fields in realistic settings, and to evaluate the potential application of EM technologies to cross-borehole and single-hole environment for reservoir characterization and monitoring

  8. A short history and critical review of individual monitoring

    International Nuclear Information System (INIS)

    Wernli, Christian

    2016-01-01

    Soon after the discovery of X-rays and the radioactive element radium harmful radiation effects occurred, mainly in the medical field. Consequently, the radiologists, a new profession at that time, called for a limitation of radiation exposures. First proposals were to limit the exposure rate to prevent the incidence of skin erythema. It took more than two decades and there were many victims of severe radiation effects until a sound basis for radiation protection and individual monitoring was established. For external dosimetry, the film dosemeter was invented in the 1920's. This device, often combined with an ion chamber-based pencil dosemeter, dominated the systems used in personnel dosimetry until the end of the twentieth century. For internal exposure, the concept of limiting the 'body burden' was commonly used, and only in the late 1970's, the new concept of the 'effective dose equivalent' published in ICRP publication 26 allowed for a unified interpretation and, therefore, addition of the dosimetric quantities for external and internal exposures. By the end of the last century, individual monitoring had to survive an inflation of proposals for new quantities, but fortunately, it was also the time of vast developments of new technologies, methods and procedures. Later on, much room was given to highly sophisticated regulations, requirements, metrological concepts and administrative procedures. In this complex environment, the original task of individual monitoring became more and more hidden behind secondary loads. Now, like about hundred years ago, however with different motivation, once again the ultimate goal of the professional work has to be thought about by asking: Do people always know why they do what they do? Or simply: Why individual monitoring? (authors)

  9. Adequacy of individual monitoring of external exposure at the workplace

    International Nuclear Information System (INIS)

    Rannou, A.

    2006-01-01

    Individual monitoring of workers exposed to external radiations must fulfill technical, regulatory and organizational requirements. The external dosimetry should be adapted to the workplace. The relevant dosimetric techniques have to be chosen upon the workplace study that conditions both the categorization of exposed workers and classification of areas. Solutions exist which are satisfactory for the most situations. However, rational solutions still have to be found for a few specific situations. (author)

  10. Standards, documents of relevance and directives in individual monitoring: is European individual monitoring in compliance with standards?

    International Nuclear Information System (INIS)

    Fantuzzi, E.

    2005-01-01

    Full text: Individual monitoring services in Europe do not comply with the same legal or approval requirements. Anyway, a degree of harmonization existing in individual monitoring practices in Europe has been achieved mainly thank to documents as standards or international recommendations, which with a different weight, represent invaluable vehicles of condensed information transfer. However, implementation of standards is not straightforward and harmonization is not directly a consequence. Somehow, 'harmony' is needed also in standards: IEC and ISO standards on performance requirements for dosemeters sometimes have different approaches (i.e. performance criteria). If used for approval, passing one will not necessarily mean passing all. Moreover, standards do not all refer to reliability, and therefore being in compliance with standards does not itself assure that dose results are reliable. This might apply only to ISO/IEC17025 'quality' standard, which represents the best available tool for the quality of laboratory work and somehow include all technical and management requirements. When accredited according to ISO/IEC17025, an Individual Monitoring Service (IMS) fulfils standards. Standards are not the only reference documents for an IMS. EURADOS working group on 'Harmonization of Individual Monitoring in Europe', who has been active in the years 2001-2004, suggested a classification of publication on individual monitoring, distinguishing between standards and documents of relevance, which can be both national and international. A standard, unlike a textbook or technical publication, does not cover the experience and opinion of one or few individuals only, but the consensus of the entire scientific and technical community concerned. Most of the standards applicable to individual monitoring are published by IEC or ISO, or both together. However, it has to be kept in mind that ISO and IEC standards, for example, are meant for manufactures and industry, which do not

  11. Implementation of quality standards in an individual monitoring service

    International Nuclear Information System (INIS)

    Hyvoenen, H.; Vartiainen, E.

    2001-01-01

    In this paper the implementation of a quality system to the procedures of an individual monitoring service (IMS) is described from the practical perspective. The IMS of the Radiation and Nuclear Safety Authority (STUK) is used as an example. The IMS of STUK monitors about 8500 persons mainly working in hospitals, industry and research centres. The current thermoluminescence dosemeter (TLD) system was introduced in 1992 and the whole service changed to TLDs in 1995. The quality system compatible with the quality standards was introduced in 1999. An application for accreditation to full EN45001 and ISO/IEC Guide 25 was made in December 1999, accreditation was achieved in August 2000 by the Finnish Accreditation Service (FINAS). The considerations needed for the quality system to fulfil the requirements of the quality standards are reported. (author)

  12. Implementation of quality standards in an individual monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Hyvoenen, H.; Vartiainen, E

    2001-07-01

    In this paper the implementation of a quality system to the procedures of an individual monitoring service (IMS) is described from the practical perspective. The IMS of the Radiation and Nuclear Safety Authority (STUK) is used as an example. The IMS of STUK monitors about 8500 persons mainly working in hospitals, industry and research centres. The current thermoluminescence dosemeter (TLD) system was introduced in 1992 and the whole service changed to TLDs in 1995. The quality system compatible with the quality standards was introduced in 1999. An application for accreditation to full EN45001 and ISO/IEC Guide 25 was made in December 1999, accreditation was achieved in August 2000 by the Finnish Accreditation Service (FINAS). The considerations needed for the quality system to fulfil the requirements of the quality standards are reported. (author)

  13. Acoustic and Optical Televiewer Borehole Logging

    International Nuclear Information System (INIS)

    Ahmad Hasnulhadi Che Kamaruddin; Nik Marzukee Nik Ibrahim; Zaidi Ibrahim; Nurul Wahida Ahmad Khairuddin; Azmi Ibrahim

    2016-01-01

    This review paper is focused on Borehole Televiewer. Borehole Televiewer or (BHTV) was used to obtain high-resolution acoustical images from the borehole wall. A probe with a high resolution downward looking camera is used. The camera has specific optics (a conical mirror with a ring of bulbs) with just one shot needed to capture the entire borehole circumference as a 360 panoramic view. Settings similar to traditional cameras (exposure, quality, light, frame rate and resolution) make it effective in almost any type of borehole fluid. After each shot, a series of horizontal pixel strings are acquired, giving a rasterized RGB picture in real-time which is transmitted to the console and finally to a monitor. The orientation device embedded in the tool, which is made of 3 inclinometers and 3 magnetometers, allows the inclination and azimuth of the probe to be computed in real-time, correctly orienting the borehole images. Besides, Acoustic and Optical Televiewer has been introduced as its advanced in technological research. Its logging has been successfully applied to geotechnical investigations and mineral exploration (Schepers et al., 2001) due to advances in beam focusing, increased dynamic range, digital recording techniques, and digital data processing (Schepers, 1991). Thus, this paper will go through to the basic principle of (BHTV) as one type of data collection today. (author)

  14. Education and training issues in individual monitoring of ionising radiation

    International Nuclear Information System (INIS)

    Dimitriou, P.; Kamenopoulou, V.

    2011-01-01

    The present article deals with the education and training (E and T) issues of individual monitoring (IM) of ionising radiation, based on the requirements provided by the Basic Safety Standards EURATOM Directive and the European Commission Technical Recommendations for IM of external radiation. The structure and the objectives of E and T programmes addressed to the staff of dosimetry services, in order to allow the recognition and ensure the continuity of expertise are discussed. The necessity for the establishment of a national strategy for building competence in IM through information, education, training and retraining programmes, addressed to the individually monitored personnel is underlined. The train the trainers' concept is recognised as being an important tool for optimising resources and transferring the skills necessary for building competence. The conditions under which an efficient train the trainers' approach can be established are discussed. Examples of curricula concerning the key persons involved in the provision of E and T in occupational radiation protection are also given. (authors)

  15. Quality assurance in individual monitoring of ionizing radiation

    International Nuclear Information System (INIS)

    Julius, H.W.

    1988-01-01

    In todays world, where competition gets tougher, there is a growing consciousness of Quality Assurance (QA) and Quality Control (QC) being key elements to success. This does not only apply o manufacturing of industrial products, it is equally true for public services. Because of the increasing awareness in our modern societies of the quality of life and hence of optimal health care and general safety, it is also the general public that calls for 'products' of the highest possible quality. Good examples of the latter are the continuously improving safety standards for automobiles, for medical diagnostic imaging and for the working environment. Therefore, QA unquestionably plays a vital role in individual monitoring of ionizing radiation, especially since the media talked so many into some sort of radiation phobia. In the following an attempt is made to roughly outline some aspects that may come into play if QA is applied to routine personnel dosimetry. The author wants to emphasize that the subject, which has hardly been dealt with in the professional literature on radiation dosimetry, is a rather 'soft' one. There may be a large number of different approaches to QA, depending on special local situations and individual - sometimes national - views. It should therefore be considered as a general guide, provided in the form of (check)lists containing items of interest in routine monitoring

  16. Seven years of individual monitoring service in Cuba

    International Nuclear Information System (INIS)

    Cruz Suarez, R.; Diaz Bernal, E.D.; Lopez Bejerano, G.M.; Jova Sed, L.A.

    1996-01-01

    The Center for Radiation Protection and Hygiene (CPHR) has been carrying out from 1987 the individual monitoring of workers occupationally exposed to the ionizing radiations in the Republic of Cuba, excepting those that employ X-rays in diagnostic radiology. In this paper the results of the individual monitoring services during the period 1987-1993 are discussed. For all occupational practices the current system of dose limitation established in the country with 50 mSv as limit of annual dose is satisfied. The distribution in all occupational practices other than nuclear medicine and gamma-therapy is characterized by having more than 95% of the controlled personnel with an effective dose lower than 5 mSv. In the case of nuclear medicine and gamma-therapy more than 80% of the workers were below that dose value. For the practices evaluated in this paper the possibility of assuming the system of dose limitation recommended by ICRP is evident. The evaluations carried out for the introduction of operational quantities H p (0.07) and H p (10) in dose assessment procedure are presented. The expressions obtained during the characterization of the film badge dosemeter, in terms of operational quantities guarantees a deviation of response of the dosemeter with depending upon energies, lower than 20 %. (author)

  17. ASSESSMENT OF HEAVY METAL STATUS OF BOREHOLES IN ...

    African Journals Online (AJOL)

    Osondu

    2012-02-13

    Feb 13, 2012 ... monitoring and assessment of boreholes mostly the indiscriminate sinking of boreholes in the ... Ethiopian Journal of Environmental Studies and Management Vol. 5 No.1 2012 ... may enter a water supply by industrial and ... issues of present day research on risk .... and pigments for paints, cement, paper,.

  18. Borehole temperature variability at Hoher Sonnblick, Austria

    Science.gov (United States)

    Heinrich, Georg; Schöner, Wolfgang; Prinz, Rainer; Pfeiler, Stefan; Reisenhofer, Stefan; Riedl, Claudia

    2016-04-01

    The overarching aim of the project 'Atmosphere - permafrost relationship in the Austrian Alps - atmospheric extreme events and their relevance for the mean state of the active layer (ATMOperm)' is to improve the understanding of the impacts of atmospheric extreme events on the thermal state of the active layer using a combined measurement and modeling approach as the basis for a long-term monitoring strategy. For this purpose, the Sonnblick Observatory at the summit of Hoher Sonnblick (3106 m.a.s.l) is particularly well-suited due to its comprehensive long-term atmospheric and permafrost monitoring network (i.a. three 20 m deep boreholes since 2007). In ATMOperm, a robust and accurate permanent monitoring of active layer thickness at Hoher Sonnblick will be set up using innovative monitoring approaches by automated electrical resistivity tomography (ERT). The ERT monitoring is further supplemented by additional geophysical measurements such as ground penetrating radar, refraction seismic, electromagnetic induction and transient electromagnetics in order to optimally complement the gained ERT information. On the other hand, atmospheric energy fluxes over permafrost ground and their impact on the thermal state of permafrost and active layer thickness with a particular focus on atmospheric extreme events will be investigated based on physically-based permafrost modeling. For model evaluation, the borehole temperature records will play a key role and, therefore, an in-depth quality control of the borehole temperatures is an important prerequisite. In this study we will show preliminary results regarding the borehole temperature variability at Hoher Sonnblick with focus on the active layer. The borehole temperatures will be related to specific atmospheric conditions using the rich data set of atmospheric measurements of the site in order to detect potential errors in the borehole temperature measurements. Furthermore, we will evaluate the potential of filling gaps in

  19. Dose record keeping: a multi purpose tool in individual monitoring

    International Nuclear Information System (INIS)

    Bermann, F.; Julius, H.W.

    1993-01-01

    Proper recording of radiation doses is an essential part of the process of individual monitoring and shares in the same objective. A dose record keeping system is more than just a computer based data storage system and should rather be a Dose Registration and Information System (DRIS). Objectives of dose record keeping are given. As a result of the integration of member states of the European Communities, co-operation and exchange of personnel between countries will be increasing. This will probably require national dose registration systems and adequate data communication between them. These developments emphasize the necessity for international harmonization of dose record keeping systems and categorization of the data they contain. General characteristics and specific aspects of dose record keeping systems will be dealt with. Attention will also be given to some special applications of the recorded information, such as: the use of data for epidemiological studies and for QA purposes. (authors). 5 tabs., 4 refs

  20. Required accuracy and dose thresholds in individual monitoring

    DEFF Research Database (Denmark)

    Christensen, P.; Griffith, R.V.

    1994-01-01

    this uncertainty factor, a value of 21% can be evaluated for the allowable maximum overall standard deviation for dose measurements at dose levels near the annual dose limits increasing to 45% for dose levels at the lower end of the dose range required to be monitored. A method is described for evaluating...... the overall standard deviation of the dosimetry system by combining random and systematic uncertainties in quadrature, and procedures are also given for determining each individual uncertainty connected to the dose measurement. In particular, attention is paid to the evaluation of the combined uncertainty due...... to energy and angular dependencies of the dosemeter. In type testing of personal dosimetry systems, the estimated overall standard deviation of the dosimetry system is the main parameter to be tested. An important characteristic of a personal dosimetry system is its capability of measuring low doses...

  1. Geophysical monitoring of the EDZ during a gallery excavation in the Opalinus clay of the Mont Terri URL: anomalies of noble gases and self-potential associated with fractures and fluid dynamics in a horizontal borehole

    International Nuclear Information System (INIS)

    Maineult, A.; Mahiouz, K.; Lesparre, N.; Thomas, B.; Lavielle, B.; Nussbaum, C.; Wieczorek, K.; Gibert, D.; Kergosien, B.; Nicollin, F.

    2012-01-01

    Document available in extended abstract form only. The research underground rock laboratory (URL) of Mont Terri (Switzerland) was established in 1996 in a Mesozoic clay-stone formation (Opalinus Clay). It is aimed at studying the hydro-mechanical, thermal, geochemical and geophysical behaviour of argillaceous formations in the context of radioactive waste disposal. The EZ-G experiments were designed to monitor the EDZ evolution. The EZ-G08 experiment started in September 2007 to study the EDZ changes at different time scales during the tunnelling of gallery Ga08 starting from the northern part of the URL toward the end-face of the gallery Ga04. Before the excavation process started, we characterized the petrology and the structural properties of the core of the horizontal, 12-m long borehole BEZ-G5 drilled in the end-face of gallery Ga04 (first 2 meters in the shaly facies, the rest in the sandy facies). We quantified its noble gas content for studying gas transport processes in rocks and connected fracture networks. Depletion in He can be observed in the EDZ and other noble gases can also increase as desaturation processes occur. Inflows of water occurred in the borehole few weeks after its drilling until the junction of galleries Ga08 and Ga04. Water amounts of few litres were commonly released in other boreholes in the URL. We recorded the natural electrical potentials (self-potentials - SP), in BEZ-G5. SP originate from the movement of fluid, the diffusion of concentration or temperature gradients, and are sensitive to any change occurring in them. Borehole BEZ-G5 was equipped with a specific device, on which custom-made electrodes were fixed every 15 cm. The signals showed coherent perturbations during the drilling operations in the boreholes BEZ-G12 and in the end-face of the gallery Ga04. Afterwards, an early, strong but rather smooth increase of a few tens of mV, followed by a very slow decrease of much smallest amplitude, can be observed in some signals

  2. Comparison of Performance of Public and Private Boreholes ...

    African Journals Online (AJOL)

    In the last fifteen years, a remarkable increase in the number of privately owned. There has been an increase in the individually owned and operated boreholes within the state because it is claimed that government owned boreholes breakdown too often. Hence, this study is aimed at comparison of the performance of three ...

  3. Measuring depth in boreholes

    International Nuclear Information System (INIS)

    Hodson, G.M.

    1979-01-01

    This invention relates to a method of determining the depth of rock strata and other features of a borehole. It may be employed with particular advantage when access to the top of the borehole is difficult, for example in underwater operations. A radioactive marker, such as a source of gamma rays, is positioned near the top of the riser of a sub-sea wellhead structure. A radiation detector is lowered between the marker and a radioactive stratum and the length of line supplied is measured on the floating platform. This enables the depth of the stratum to be measured irrespective of tidal variations of the height of the platform. (U.K.)

  4. Deep boreholes; Tiefe Bohrloecher

    Energy Technology Data Exchange (ETDEWEB)

    Bracke, Guido [Gesellschaft fuer Anlagen- und Reaktorsicherheit gGmbH Koeln (Germany); Charlier, Frank [NSE international nuclear safety engineering gmbh, Aachen (Germany); Geckeis, Horst [Karlsruher Institut fuer Technologie (Germany). Inst. fuer Nukleare Entsorgung; and others

    2016-02-15

    The report on deep boreholes covers the following subject areas: methods for safe enclosure of radioactive wastes, requirements concerning the geological conditions of possible boreholes, reversibility of decisions and retrievability, status of drilling technology. The introduction covers national and international activities. Further chapters deal with the following issues: basic concept of the storage in deep bore holes, status of the drilling technology, safe enclosure, geomechanics and stability, reversibility of decisions, risk scenarios, compliancy with safe4ty requirements and site selection criteria, research and development demand.

  5. Borehole DC-12 hydrostratigraphic chart

    International Nuclear Information System (INIS)

    Gephart, R.E.

    1981-09-01

    This hydrostratigraphic chart identifies the basic stratigraphy and preliminary hydrologic testing results for Borehole DC-12. This borehole was cored through the Saddle Mountains and Wanapum basalt formations and into the Grande Ronde. Selected zones were hydrologically tested during coring

  6. Borehole DC-14 hydrostratigraphic chart

    International Nuclear Information System (INIS)

    Gephart, R.E.

    1981-09-01

    This hydrostratigraphic chart identifies the basic stratigraphy and preliminary hydrologic testing results for Borehole DC-14. This borehole was cored through the Saddle Mountains and Wanapum basalt formations and into the Grande Ronde. Selected zones were hydrologically tested during coring

  7. Borehole DC-15 hydrostratigraphic chart

    International Nuclear Information System (INIS)

    Gephart, R.E.

    1981-09-01

    This hydrostratigraphic chart identifies the basic stratigraphy and preliminary hydrologic testing results for Borehole DC-15. This borehole was cored through the Saddle Mountains and Wanapum basalt formations and into the Grande Ronde. Selected zones were hydrologically tested during coring

  8. Borehole logging system

    International Nuclear Information System (INIS)

    Allen, L.S.

    1988-01-01

    A radioactive borehole logging tool employs an epithermal neutron detector having a neutron counter surrounded by an inner thermal neutron filter and an outer thermal neutron filter. Located between the inner and outer filters is a neutron moderating material for extending the lifetime of epithermal neutrons to enhance the counting rate of such epithermal neutrons by the neutron counter

  9. Geophysical borehole logging

    International Nuclear Information System (INIS)

    McCann, D.; Barton, K.J.; Hearn, K.

    1981-08-01

    Most of the available literature on geophysical borehole logging refers to studies carried out in sedimentary rocks. It is only in recent years that any great interest has been shown in geophysical logging in boreholes in metamorphic and igneous rocks following the development of research programmes associated with geothermal energy and nuclear waste disposal. This report is concerned with the programme of geophysical logging carried out on the three deep boreholes at Altnabreac, Caithness, to examine the effectiveness of these methods in crystalline rock. Of particular importance is the assessment of the performance of the various geophysical sondes run in the boreholes in relation to the rock mass properties. The geophysical data can be used to provide additional in-situ information on the geological, hydrogeological and engineering properties of the rock mass. Fracturing and weathering in the rock mass have a considerable effect on both the design parameters for an engineering structure and the flow of water through the rock mass; hence, the relation between the geophysical properties and the degree of fracturing and weathering is examined in some detail. (author)

  10. Cleaning of boreholes

    International Nuclear Information System (INIS)

    Rautio, T.; Alaverronen, M.; Lohva, K.; Teivaala, V.

    2004-09-01

    In terms of long-term safety it is a risk that the boreholes can eventually function as short-circuits between the repository and ground surface. Therefore sealing of investigation boreholes is an important issue for the long- term safety of high-level nuclear waste repositories. In order to seal a borehole properly, the conditions of the borehole have to meet certain predetermined requirements. One of the requirements is that no instruments or materials endangering the plugging operation or the long-term function of the sealing materials, are allowed to be left in the borehole. Sometimes drilling equipment will be left in the hole or it cannot be recovered from the hole with the given constraints of time, cost and resources in spite of attempts. Additionally various measurements may be carried out in the holes after the drilling has been completed and measuring devices may get stuck in holes. Consequently cleaning of the borehole is carried out as an essential activity before sealing can be implemented. There are two common reasons identified for the drill strings to get stuck in holes. First the drill string may get stuck due to acute drilling problems. The second case is where rods are left as casing in a hole either based on the structure of the upper part of the hole or in order to support the hole. To remove the drilling or measuring equipment lost in a borehole, special techniques and professional skill must be applied. Removing measuring equipment from a hole is often demanding and time consuming work. A vital part of the cleaning operation is planning the work in advance. In order to make the plan and to select the suitable methods it is important to know the condition of the stuck material. It is also important to know the exact depth where the equipment are stuck and to have an estimate of the reasons why they have got stuck. It is also very important to know the correct dimensions of the equipment or drill string before commencing the cleaning work

  11. Individual monitoring program for internal contamination by inhaled uranium

    International Nuclear Information System (INIS)

    Vazquez, C.; Chapel, M.L.; Saenz Gancedo, R.

    1988-01-01

    The metabolic behaviour of inhaled uranium is studied. Using a particular analytical method applied to the models and dose assessment methods recommended by ICRP, the organ committed equivalent dose and effective equivalent dose are calculated. The exact ALI and DAC are derived from there. In the paper, the influence that various parameters have on those results are considered for the specific case of a particular nuclear element fabrication factory. Different AMAD and solubility type of inhaled material are specially analyzed. The results show the paramount importance of some of these parameters on the secondary and derived dose limits. Relationships between the real intake, as a fraction of ALI, and the lung retention or urine excretion are shown for different cases and intake forms hypothesis. Minimum detectable intakes with the available experimental techniques are then established. The results shown in the papel are a useful tool to help on the decision on the type and frequency of the individual monitoring techniques to be established in different circumstances. (Author)

  12. A CR-39 track dosemeter for routine individual neutron monitoring

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Alberts, W.G.; Dietz, E.; Guldbakke, S.; Matzke, M.; d'Errico, F.

    1994-01-01

    A personal neutron dosemeter for routine individual monitoring is proposed. It is based on a CR-39 track detector covered on three separate areas by converters with different boron contents and inserted into a commercial TLD albedo dosemeter capsule. The dose readings from three areas of the electrochemically etched CR-39 detector are combined to yield a dose equivalent response which is almost independent of the incident neutron energy in the range from thermal neutrons up to 20 MeV. In addition, the dose contributions of thermal, intermediate and fast neutrons can be determined separately. Unlike the TLD albedo dosemeter, which in general requires prior in-field calibration and whose use is then restricted to that field, this dosemeter can be used in neutron fields without any knowledge of the spectral distribution with the same calibration factor. The angular dependence of the dosemeter's response has been measured and compared with that of the directional dose equivalent H'(10). The lower limit of detection is 0.15 mSv. It is possible to obtain an independent, second dose reading from the same Cr-39 detector for neutron energies above 100 keV. The dosemeter has also been successfully tested for use in accident dosimetry applying chemical etching and an optical density reading of the CR-39 detector. (author)

  13. Audit experience in external individual monitoring services accreditation in Brazil

    International Nuclear Information System (INIS)

    Martins, M.M.; Fonseca, E.S.; Pereira, W.W.; Ramos, M.M.O.; Salati, I.P.A.

    1998-01-01

    Brazilian Nuclear Energy Commission (CNEN) has been carrying out an accreditation program for the External Individual Monitoring Services (named SMIE) for about 45.000 workers involved with ionizing radiation. One of this steps of this accreditation program is the audit to each SMIE. The main audit objective is to verify and to check organizational documentation, system performance test, technical personnel ability and training, quality assurance system procedures and records, essential equipment and facilities and reliability of dose reports. In order to avoid a different audit for each SMIE, effort were made to obtain a standard process. Two aspects were considered the most relevant ones: human resources training and audit procedures. To achieve the first one, a practical and theoretical course taking into account auditing needs was elaborated. As well as experience in one of the technical related areas, an important condition to be member of an audit team is to obtain satisfactory approval in one of the offered courses. In order to accomplish the second point, a set of documents was implemented such as an audit checklist, audit report models, and procedures and recommendations to audit. Up to February 1998, 12 accreditation audits were performed. The main points of this program as well as an assessment of its difficulties and success are reported in this work

  14. External individual monitoring: experiments and simulations using Monte Carlo Method

    International Nuclear Information System (INIS)

    Guimaraes, Carla da Costa

    2005-01-01

    In this work, we have evaluated the possibility of applying the Monte Carlo simulation technique in photon dosimetry of external individual monitoring. The GEANT4 toolkit was employed to simulate experiments with radiation monitors containing TLD-100 and CaF 2 :NaCl thermoluminescent detectors. As a first step, X ray spectra were generated impinging electrons on a tungsten target. Then, the produced photon beam was filtered in a beryllium window and additional filters to obtain the radiation with desired qualities. This procedure, used to simulate radiation fields produced by a X ray tube, was validated by comparing characteristics such as half value layer, which was also experimentally measured, mean photon energy and the spectral resolution of simulated spectra with that of reference spectra established by international standards. In the construction of thermoluminescent dosimeter, two approaches for improvements have. been introduced. The first one was the inclusion of 6% of air in the composition of the CaF 2 :NaCl detector due to the difference between measured and calculated values of its density. Also, comparison between simulated and experimental results showed that the self-attenuation of emitted light in the readout process of the fluorite dosimeter must be taken into account. Then, in the second approach, the light attenuation coefficient of CaF 2 :NaCl compound estimated by simulation to be 2,20(25) mm -1 was introduced. Conversion coefficients C p from air kerma to personal dose equivalent were calculated using a slab water phantom with polymethyl-metacrilate (PMMA) walls, for reference narrow and wide X ray spectrum series [ISO 4037-1], and also for the wide spectra implanted and used in routine at Laboratorio de Dosimetria. Simulations of backscattered radiations by PMMA slab water phantom and slab phantom of ICRU tissue-equivalent material produced very similar results. Therefore, the PMMA slab water phantom that can be easily constructed with low

  15. Aespoe Hard Rock Laboratory. BIPS logging in borehole KAS09

    International Nuclear Information System (INIS)

    Gustafsson, Jaana; Gustafsson, Christer

    2010-01-01

    This report includes the data gained in BIPS logging performed at the Aespoe Hard Rock Laboratory. The logging operation presented here includes BIPS logging in the core drilled borehole KAS09. The objective for the BIPS logging was to observe the condition of KAS09 in order to restore the borehole in the hydrogeological monitoring programme.All measurements were conducted by Malaa Geoscience AB on October 9th 2009. The objective of the BIPS logging is to achieve information of the borehole including occurrence of rock types as well as determination of fracture distribution and orientation. This report describes the equipment used as well as the measurement procedures and data gained. For the BIPS survey, the result is presented as images. The basic conditions of the BIPS logging for geological mapping and orientation of structures are satisfying for borehole KAS09, although induced affects from the drilling on the borehole walls limit the visibility

  16. Aespoe Hard Rock Laboratory. BIPS logging in borehole KAS09

    Energy Technology Data Exchange (ETDEWEB)

    Gustafsson, Jaana; Gustafsson, Christer (Malaa Geoscience AB (Sweden))

    2010-01-15

    This report includes the data gained in BIPS logging performed at the Aespoe Hard Rock Laboratory. The logging operation presented here includes BIPS logging in the core drilled borehole KAS09. The objective for the BIPS logging was to observe the condition of KAS09 in order to restore the borehole in the hydrogeological monitoring programme.All measurements were conducted by Malaa Geoscience AB on October 9th 2009. The objective of the BIPS logging is to achieve information of the borehole including occurrence of rock types as well as determination of fracture distribution and orientation. This report describes the equipment used as well as the measurement procedures and data gained. For the BIPS survey, the result is presented as images. The basic conditions of the BIPS logging for geological mapping and orientation of structures are satisfying for borehole KAS09, although induced affects from the drilling on the borehole walls limit the visibility

  17. Neutron borehole logging correction technique

    International Nuclear Information System (INIS)

    Goldman, L.H.

    1978-01-01

    In accordance with an illustrative embodiment of the present invention, a method and apparatus is disclosed for logging earth formations traversed by a borehole in which an earth formation is irradiated with neutrons and gamma radiation produced thereby in the formation and in the borehole is detected. A sleeve or shield for capturing neutrons from the borehole and producing gamma radiation characteristic of that capture is provided to give an indication of the contribution of borehole capture events to the total detected gamma radiation. It is then possible to correct from those borehole effects the total detected gamma radiation and any earth formation parameters determined therefrom

  18. Site response assessment using borehole seismic records

    Energy Technology Data Exchange (ETDEWEB)

    Park, Donghee; Chang, Chunjoong; Choi, Weonhack [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In regions with high seismic activity, such as Japan, the Western United States and Taiwan, borehole seismometers installed deep underground are used to monitor seismic activity during the course of seismic wave propagation at various depths and to study the stress changes due to earthquakes and analyze the connection to fault movements. The Korea Meteorological Administration (KMA) and the Korea Institute of Geology and Mining (KIGAM) have installed and are operating borehole seismometers at a depth of 70∼100 meters for the precise determination of epicenters. Also, Korea Hydro and Nuclear Power Co., Ltd. (KHNP) has installed and is operating 2 borehole seismic stations near Weolseong area to observe at a depth of 140 meters seismic activities connected to fault activity. KHNP plans to operate in the second half of 2014 a borehole seismic station for depths less than 300 and 600 meters in order to study the seismic response characteristics in deep strata. As a basic study for analyzing ground motion response characteristics at depths of about 300 to 600 meters in connection with the deep geological disposal of spent nuclear fuel, the present study examined the background noise response characteristics of the borehole seismic station operated by KHNP. In order to analyze the depth-dependent impact of seismic waves at deeper depths than in Korea, seismic data collected by Japan's KIK-net seismic stations were used and the seismic wave characteristics analyzed by size and depth. In order to analyze the borehole seismic observation data from the seismic station operated by KHNP, this study analyzed the background noise characteristics by using a probability density function.

  19. Site response assessment using borehole seismic records

    International Nuclear Information System (INIS)

    Park, Donghee; Chang, Chunjoong; Choi, Weonhack

    2014-01-01

    In regions with high seismic activity, such as Japan, the Western United States and Taiwan, borehole seismometers installed deep underground are used to monitor seismic activity during the course of seismic wave propagation at various depths and to study the stress changes due to earthquakes and analyze the connection to fault movements. The Korea Meteorological Administration (KMA) and the Korea Institute of Geology and Mining (KIGAM) have installed and are operating borehole seismometers at a depth of 70∼100 meters for the precise determination of epicenters. Also, Korea Hydro and Nuclear Power Co., Ltd. (KHNP) has installed and is operating 2 borehole seismic stations near Weolseong area to observe at a depth of 140 meters seismic activities connected to fault activity. KHNP plans to operate in the second half of 2014 a borehole seismic station for depths less than 300 and 600 meters in order to study the seismic response characteristics in deep strata. As a basic study for analyzing ground motion response characteristics at depths of about 300 to 600 meters in connection with the deep geological disposal of spent nuclear fuel, the present study examined the background noise response characteristics of the borehole seismic station operated by KHNP. In order to analyze the depth-dependent impact of seismic waves at deeper depths than in Korea, seismic data collected by Japan's KIK-net seismic stations were used and the seismic wave characteristics analyzed by size and depth. In order to analyze the borehole seismic observation data from the seismic station operated by KHNP, this study analyzed the background noise characteristics by using a probability density function

  20. Harmonisation (legal, dosimetric, quality aspects) of individual monitoring, and integration of monitoring for external and internal exposures (EURADOS working group)

    International Nuclear Information System (INIS)

    Lopez, M.A.; Currivan, L.; Falk, R.; Olko, P.; Wernli, C.; Castellani, C.M.; Dijk, J.W.E. van

    2003-01-01

    The EURADOS Working Group II on 'Harmonisation of individual monitoring' consists of experts from almost all EU Member States and Newly Associated States (NAS), involved in tasks related to the assessment of doses for internal and external radiation. The final objective is to achieve harmonisation in individual monitoring for occupational exposures. Sub-group 2 activities are focused on investigating how the results from personal dosemeters for external radiation and workplace monitoring and from monitoring for internal exposure can be combined into a complete and consistent system of individual monitoring. Three questionnaires were prepared, covering Individual monitoring of external radiation (Questionnaire 1), 'Internal exposure' (Questionnaire 2) and 'Natural sources of radiation at workplace' (Questionnaire 3). With the agreement of a 'contact-person' selected in each country, the distribution of the three EURADOS 2002 questionnaires was carried out by e-mail among the dosimetry facilities of 28 European countries. The preliminary results of these actions are presented here. (author)

  1. Directional borehole antenna - Theory

    International Nuclear Information System (INIS)

    Falk, L.

    1992-02-01

    A directional antenna has been developed for the borehole radar constructed during phase 2 of the Stripa project. The new antenna can determine the azimuth of a strong reflector with an accuracy of about 3 degrees as confirmed during experiments in Stripa, although the ratio of borehole diameter to wavelength is small, about 0.03. The antenna synthesizes the effect of a loop antenna rotating in the borehole from four signals measured in turn by a stationary antenna. These signals are also used to calculate an electric dipole signal and a check sum which is used to examine the function of the system. The theory of directional antennas is reviewed and used to design an antenna consisting of four parallel wires. The radiation pattern of this antenna is calculated using transmission line theory with due regard to polarization, which is of fundamental importance for the analysis of directional data. In particular the multipole expansion of the field is calculated to describe the antenna radiation pattern. Various sources of error, e.g. the effect of the borehole, are discussed and the methods of calibrating the antenna are reviewed. The ambiguity inherent in a loop antenna can be removed by taking the phase of the signal into account. Typical reflectors in rock, e.g. fracture zones an tunnels, may be modelled as simple geometrical structures. The corresponding analysis is described and exemplified on measurements from Stripa. Radar data is nowadays usually analyzed directly on the computer screen using the program RADINTER developed within the Stripa project. An algorithm for automatic estimation of the parameters of a reflector have been tested with some success. The relation between measured radar data and external coordinates as determined by rotational indicators is finally expressed in terms of Euler angles. (au)

  2. Single-borehole techniques

    International Nuclear Information System (INIS)

    Klotz, D.; Moser, H.; Trimborn, P.

    1978-01-01

    Proceeding on the theoretical considerations and on the experience and practice derived from laboratory and field testing, a system consisting of tracer injection units, detector units, measuring probe units and packers is presented, from which the different borehole probes required can be combined. A couple of examples of recent applications shows the position of the Single-Borehole Techniques with respect to the traditional methods used for the measurement of the ground-water flow. A confrontation of the permeabilities of different aquifers consents, both on the basis of the Single-Borehole Techniques as by pumping experiments, the determination of the reliability of the Point-Dilution-Method. The Point-Dilution-Method is giving information about the vertical and horizontal distribution of the permeabilities in an aquifer. By measuring the vertical current in two karst wells, the tributary horizons of a well have been determined, which gave valuable information for the subsequent well construction. Local leakages could be detected by measuring the vertical flow rate through observation wells arranged along a grout curtain erected on both sides of the retaining barrage of the Keban dam. (orig.) [de

  3. Borehole disposal design concept

    International Nuclear Information System (INIS)

    RANDRIAMAROLAHY, J.N.

    2007-01-01

    In Madagascar, the sealed radioactive sources are used in several socioeconomic sectors such as medicine, industry, research and agriculture. At the end of their useful lives, these radioactive sources become radioactive waste and can be still dangerous because they can cause harmful effects to the public and the environment. This work entitled 'Borehole disposal design concept' consists in putting in place a site of sure storage of the radioactive waste, in particular, sealed radioactive sources. Several technical aspects must be respected to carry out such a site like the geological, geomorphologic, hydrogeologic, geochemical, meteorological and demographic conditions. This type of storage is favorable for the developing countries because it is technologically simple and economic. The cost of construction depends on the volume of waste to store and the depth of the Borehole. The Borehole disposal concept provides a good level of safety to avoid the human intrusion. The future protection of the generations against the propagation of the radiations ionizing is then assured. [fr

  4. Basic requirements of dosemeter systems for individual monitoring of external radiation

    International Nuclear Information System (INIS)

    Boehm, J.; Ambrosi, P.

    1985-01-01

    A plea is made for detailed detector independent requirements for dosemeter systems for individual monitoring of external radiation. These requirements should have their origin in the fundamental aspects and concepts of radiation protection for workers, and should be something like a translation of the general principles of individual monitoring into a language easily understandable by producers and users. This work comprises a summary of the general objectives of individual monitoring and discussion of some relevant requirements for dosemeter systems. (orig.) [de

  5. Brazilian two-component TLD albedo neutron individual monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Martins, M.M., E-mail: marcelo@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD), Av. Salvador Allende, s/n, CEP: 22780-160, Rio de Janeiro, RJ (Brazil); Mauricio, C.L.P., E-mail: claudia@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD), Av. Salvador Allende, s/n, CEP: 22780-160, Rio de Janeiro, RJ (Brazil); Fonseca, E.S. da, E-mail: evaldo@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD), Av. Salvador Allende, s/n, CEP: 22780-160, Rio de Janeiro, RJ (Brazil); Silva, A.X. da, E-mail: ademir@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao em Engenharia, COPPE/PEN Caixa Postal 68509, CEP: 21941-972, Rio de Janeiro, RJ (Brazil)

    2010-12-15

    Since 1983, Instituto de Radioprotecao e Dosimetria, Brazil, uses a TLD one-component albedo neutron monitor, which has a single different calibration factor specifically for each installation type. In order to improve its energy response, a two-component albedo monitor was developed, which measure the thermal neutron component besides the albedo one. The two-component monitor has been calibrated in reference neutron fields: thermal, five accelerator-produced monoenergetic beams (70, 144, 565, 1200 and 5000 keV) and five radionuclide sources ({sup 252}Cf, {sup 252}Cf(D{sub 2}O), {sup 241}Am-Be, {sup 241}Am-B and {sup 238}Pu-Be) at several distances. Since January 2008, mainly Brazilian workers who handle neutron sources at different distances and moderation, such as in well logging and calibration facilities are using it routinely.

  6. Borehole sealing method and apparatus

    International Nuclear Information System (INIS)

    Hartley, J.N.; Jansen, G. Jr.

    1977-01-01

    A method and apparatus is described for sealing boreholes in the earth. The borehole is blocked at the sealing level, and a sealing apparatus capable of melting rock and earth is positioned in the borehole just above seal level. The apparatus is heated to rock-melting temperature and powdered rock or other sealing material is transported down the borehole to the apparatus where it is melted, pooling on the mechanical block and allowed to cool and solidify, sealing the hole. Any length of the borehole can be sealed by slowly raising the apparatus in the borehole while continuously supplying powdered rock to the apparatus to be melted and added to the top of the column of molten and cooling rock, forming a continuous borehole seal. The sealing apparatus consists of a heater capable of melting rock, including means for supplying power to the heater, means for transporting powdered rock down the borehole to the heater, means for cooling the apparatus and means for positioning the apparatus in the borehole. 5 claims, 1 figure

  7. Development of Web based system for individual internal monitoring programme

    International Nuclear Information System (INIS)

    Lima, Vanessa Rogeria de

    2007-01-01

    The purposes of the internal monitoring, in general, are to verify and document that each worker is protected adequately against risks from radionuclide intakes and the protection complies with legal requirements. Therefore, an overall radiation protection programme, starts with an assessment to identify work situations in which there is a risk of internal contamination of workers and to quantify the likely intake of radioactive material and the resulting committed effective dose. As a part of a continuous improvement of the monitoring programme for occupationally exposed workers at IPEN, it is being developed a Web based system to access the internal dosimetry database. The system was implemented using Hypertext Preprocessor, PHP, and a PostgreSQL database. This system will introduce a new paradigm in the routine of the internal dosimetry service, providing a fast access to the information among the measurement laboratories staff, dose evaluation group and the radiation protection supervisor. The database maintains information about worker identification, physical and chemical characteristics of the radionuclide, type of monitoring, measurement data and the dose. Moreover, this information will be readily available to provide support for regulatory compliance and quality control requirements. (author)

  8. Monitoring to Protect the Character of Individual Wildernesses

    Science.gov (United States)

    David N. Cole

    2006-01-01

    A primary goal of wilderness stewardship is to protect individual wilderness areas from most anthropogenic change. Numerous agents of change threaten to degrade wilderness character. These agents of change are both internal (for example, grazing) and external (for example, polluting industries) to wilderness. They can be activities (for example, recreation use) or the...

  9. Borehole DC-6 hydrostratigraphic chart

    International Nuclear Information System (INIS)

    Gephart, R.E.

    1981-09-01

    This hydrostratigraphic chart for Borehole DC-6 identifies the basic stratigraphy and preliminary hydrologic test results. This borehole was cored for obtaining stratigraphic data and only that portion within the Grande Ronde formation remains open for hydrologic testing. The upper two formations were cased and cemented off

  10. Development of the national register of radiation workers: subsystem for individual monitoring of external exposure

    International Nuclear Information System (INIS)

    Yu Haitao; Niu Haowei; Sun Quanfu; Fu Yinghua; Fan Yaohua; Yue Baorong

    2010-01-01

    Objective: To develop a national registry and reporting system of individual monitoring for workers occupationally exposed to ionizing radiation. Methods: In accordance with the relevant law, regulations, standards and the current health supervision practice for radiation workers in China, to ensure more effective collection of information on individual monitoring from all levels of service providers across the country and an easy query and analysis of the collected information for both service providers and administrative institutions, the register consisted of an offline-system and a web-based information system. The off-line system consisted of 8 tables, which could easily make annual and period monitoring reports, and upload individual monitoring data in compressed and encrypted format. Web-based system consisted of 6 modules, could easily make S customized tabulations of monitoring data and show 2 trend figures. SSLVPN secure remote access was used in the system. Arranged by the Ministry of Health, training courses provided to all individual monitoring service providers and provincial administrative institutions. Results: A new and individual-based national register and reporting system of individual monitoring for workers occupationally exposed to ionizing radiation was successfully developed, and would be officially run soon. Conclusions: The establishment and running of the register would be great improvement on the national radiological health reports and produce a far-reaching impact on the individual monitoring in China. (authors)

  11. Monitoring individual traffic flows within the ATLAS TDAQ network

    CERN Document Server

    Sjoen, R; Ciobotaru, M; Batraneanu, S M; Leahu, L; Martin, B; Al-Shabibi, A

    2010-01-01

    The ATLAS data acquisition system consists of four different networks interconnecting up to 2000 processors using up to 200 edge switches and five multi-blade chassis devices. The architecture of the system has been described in [1] and its operational model in [2]. Classical, SNMP-based, network monitoring provides statistics on aggregate traffic, but for performance monitoring and troubleshooting purposes there was an imperative need to identify and quantify single traffic flows. sFlow [3] is an industry standard based on statistical sampling which attempts to provide a solution to this. Due to the size of the ATLAS network, the collection and analysis of the sFlow data from all devices generates a data handling problem of its own. This paper describes how this problem is addressed by making it possible to collect and store data either centrally or distributed according to need. The methods used to present the results in a relevant fashion for system analysts are discussed and we explore the possibilities a...

  12. Monitoring individual traffic flows within the ATLAS TDAQ network

    International Nuclear Information System (INIS)

    Sjoen, R; Batraneanu, S M; Leahu, L; Martin, B; Al-Shabibi, A; Stancu, S; Ciobotaru, M

    2010-01-01

    The ATLAS data acquisition system consists of four different networks interconnecting up to 2000 processors using up to 200 edge switches and five multi-blade chassis devices. The architecture of the system has been described in [1] and its operational model in [2]. Classical, SNMP-based, network monitoring provides statistics on aggregate traffic, but for performance monitoring and troubleshooting purposes there was an imperative need to identify and quantify single traffic flows. sFlow [3] is an industry standard based on statistical sampling which attempts to provide a solution to this. Due to the size of the ATLAS network, the collection and analysis of the sFlow data from all devices generates a data handling problem of its own. This paper describes how this problem is addressed by making it possible to collect and store data either centrally or distributed according to need. The methods used to present the results in a relevant fashion for system analysts are discussed and we explore the possibilities and limitations of this diagnostic tool, giving an example of its use in solving system problems that arise during the ATLAS data taking.

  13. New ICRU quantities for the environmental and individual monitoring. Standardization of individual dosemeters by using external beams of photon radiation

    International Nuclear Information System (INIS)

    Brosed, A.; Delgado, A.; Granados, C. E.

    1987-01-01

    The quantities introduced by ICRU for the radiological monitoring are commented, specially those implied in individual protection against external photons. A procedure is proposed in order to standardize the individual dosemeters by using the kerma in air references of CIEMAT-JEN. The reference radiation beams are described in connection with ISO standards. Provisional values are selected for the appropriate conversion and correction factors. (Author) 23 refs

  14. Evaluation of geophysical borehole studies

    International Nuclear Information System (INIS)

    Brotzen, O.; Duran, O.; Magnusson, K.Aa.

    Four studies concerning geophysical investigations and TV inspection in boreholes in connection with KBS studies at Finnsjoe, Karlshamn, Kraakemaala and Stripa and PRAV's studies at Studsvik have been evaluated. This has led to proposals concerning the choice of instruments and methods for future studies and a review of future work required. The evaluation has shown that the following borehole measurements are of primary interest in the continued work: Determinations of temperature and resistivity of the borehole liquid, resistance and resistivity measurements, SP, Sonic, Caliper and VLF. TV inspection, IP and gamma-gamma should also be included in the arsenal of available test methods.(author)

  15. Borehole Seismology: Fundamentals and Applications

    International Nuclear Information System (INIS)

    Bohnhoff, Marco

    2014-01-01

    Because boring in itself is very expensive and instrumentation is required to endure high temperatures and pressures, deep borehole observation was accompanied by an economic risk. However, it has great advantages with respect to micro-earthquake observation, which is enriched with a short period vibration signal, because deep borehole observation greatly reduces short period noise. These kind advantages were explained by referring to the relationship between earthquake size and frequency range. Examples of seismic observation in a borehole in a geothermal field in El Salvador and a CO 2 confinement project in the western part of Canada were introduced. (authors)

  16. Data Communication PC/NaI-borehole probe (Hardware & Software)

    DEFF Research Database (Denmark)

    Madsen, Peter Buch

    Development of new hard- & software to a NaI borehole probe on a PC. Save data from the probe each 10'th sec, handle the data from the probe and make calculations every 10'th sec and show the results on the monitor.......Development of new hard- & software to a NaI borehole probe on a PC. Save data from the probe each 10'th sec, handle the data from the probe and make calculations every 10'th sec and show the results on the monitor....

  17. Individual dose monitoring of occupational exposure in nuclear industry system (1991-2000)

    International Nuclear Information System (INIS)

    Yang Lianzhen; Ma Jizeng; Li Taosheng

    2005-01-01

    The summary and main results of individual dose monitoring (1990-2000) from occupational exposure in China Nuclear Industry System are presented in this paper. During ten years, the external collective effective dose to workers in seven plants (not uranium mines and processing mills) and institutes is 98.48 person ·Sv, the per capita effective dose is 1.97 mSv. The general situation for individual dose monitoring from internal exposure is also introduced. The annual average committed effective dose is less than 5.0 mSv. The individual dose monitoring results (1991-1992) for occupational exposure from Uranium mines and processing mills are depicted. In the end, the individual dose monitoring data in nuclear industry system are preliminarily analysed. (authors)

  18. Quality control and quality assurance in individual monitoring of ionising radiations

    International Nuclear Information System (INIS)

    Dutt, J.C.; Lindborg, L.

    1994-01-01

    This paper describes the programmes and approaches that are to be considered in developing and introducing quality assurance and quality control procedures in individual monitoring services. Quality assurance and quality control in individual monitoring services are essential to maintain quality and are of increasing importance in order to meet the requirements of national regulations and international standards and guidelines. It is recommended here that all organisations offering individual monitoring services should run their services based on the principles of Quality System as given in the European Standard EN45001 and maintain a property resources QA/QC programme as an integral part of their operations. All aspects of QA/QC in individual monitoring services starting from the initial selection, installation, calibration, and operation to the final products including dose reporting, dose record keeping, dealing with customers' complaints and product liability issues have been discussed. (Author)

  19. An approach to routine individual internal dose monitoring at the object 'Shelter' personnel considering uncertainties

    International Nuclear Information System (INIS)

    Mel'nichuk, D.V.; Bondarenko, O.O.; Medvedjev, S.Yu.

    2002-01-01

    An approach to organisation of routine individual internal dose monitoring of the personnel of the Object 'Shelter' is presented in the work, that considers individualised uncertainties. In this aspect two methods of effective dose assessment based on bioassay are considered in the work: (1) traditional indirect method at which application results of workplace monitoring are not taken into account, and (2) a combined method in which both results of bioassay measurements and workplace monitoring are considered

  20. The computerized management for individual monitoring data in Daya Bay Nuclear Power Station

    International Nuclear Information System (INIS)

    Lin Shumou; Yang Xiaochen

    1995-01-01

    The authors report the individual monitoring data management system (IDOSE) at Daya Bay Nuclear Power Station. The components of the individual monitoring system, the design requirements of IDOSE, the characteristics and application of this computerized management system are mainly presented. Its application shows that IDOSE meets the requirements of the concerning occupational standards of the state and matches with the requirements of IAEA/ISOE

  1. 10 CFR 20.1502 - Conditions requiring individual monitoring of external and internal occupational dose.

    Science.gov (United States)

    2010-01-01

    ... external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive... 10 Energy 1 2010-01-01 2010-01-01 false Conditions requiring individual monitoring of external and internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR...

  2. Drilling a borehole for LEP

    CERN Multimedia

    1981-01-01

    Boreholes were drilled along the earlier proposed line of the LEP tunnel under the Jura to find out the conditions likely to be encountered during the construction of the LEP tunnel (Annual Report 1981 p. 106, Fig. 10).

  3. Borehole closure in salt

    International Nuclear Information System (INIS)

    Fuenkajorn, K.; Daemen, J.J.K.

    1988-12-01

    Constitutive law parameters are determined from salt behavior characterization experiments. The results are applied to predict creep (time-dependent) closure of boreholes in salt specimens subjected to various loading configurations. Rheological models (linear and nonlinear viscoelastic and viscoplastic models), empirical models, and physical theory models have been formulated from the results of uniaxial creep tests, strain and stress rate controlled uniaxial tests, constant strain rate triaxial tests, cyclic loading tests, and seismic velocity measurements. Analytical solutions for a thick-walled cylinder subjected to internal and external pressures and for a circular hole in an infinite plate subjected to a biaxial or uniaxial stressfield have been derived from each of the linear viscoelastic models and from one of the empirical laws. The experimental results indicate that the salt samples behave as an elastic-viscoplastic material. The elastic behavior tends to be linear and time-independent. The plastic deformation is time-dependent. The stress increment to strain rate increment ratio gradually decreases as the stress level increases. The transient potential creep law seems to give the simplest satisfactory governing equation describing the viscoplastic behavior of salt during the transient phase. 204 refs., 27 figs., 29 tabs

  4. Condensed listing of surface boreholes at the Waste Isolation Pilot Plant Project through 31 December 1995

    International Nuclear Information System (INIS)

    Hill, L.R.; Aguilar, R.; Mercer, J.W.; Newman, G.

    1997-01-01

    This report contains a condensed listing of Waste Isolation Pilot Plant (WIPP) project surface boreholes drilled for the purpose of site selection and characterization through 31 December 1995. The US Department of Energy (DOE) sponsored the drilling activities, which were conducted primarily by Sandia National Laboratories. The listing provides physical attributes such as location (township, range, section, and state-plane coordinates), elevation, and total borehole depth, as well as the purpose for the borehole, drilling dates, and information about extracted cores. The report also presents the hole status (plugged, testing, monitoring, etc.) and includes salient findings and references. Maps with borehole locations and times-of-drilling charts are included

  5. Overview of individual monitoring and calibration of radiation monitors in the country; Panorama da monitoração individual e calibração de monitores de radiação no país

    Energy Technology Data Exchange (ETDEWEB)

    Alencar, M.A.V.; Patrão, K.C.S.; Ferreira, P.R.R.; Matta, L.E.S.C.; Peres, S.S.; Silva, F.C.A. da, E-mail: vallim@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Since 1995, the Institute of Radioprotection and Dosimetry (IRD/CNEN-RJ) has been responsible for the certification of instrument calibration laboratories and monitoring of occupationally exposed individuals (IOE), as well as monitoring and auditing the activities of eleven individual monitoring services (SMIE) and six instrument calibration laboratories (LCI) in the country. The work presents an overview of the number of IOE monitored and calibrated radiation monitors, from 2008 to 2016. The data were obtained through a census with the SMIE and LCI. The results show that in this period there was an increase of around 47% in the total number of IOE monitored and approximately 40% in the number of instrument calibrations. It was also observed the reduction of dosimetric film use and the beginning of OSLD monitoring.

  6. Individual differences in episodic memory abilities predict successful prospective memory output monitoring.

    Science.gov (United States)

    Hunter Ball, B; Pitães, Margarida; Brewer, Gene A

    2018-02-07

    Output monitoring refers to memory for one's previously completed actions. In the context of prospective memory (PM) (e.g., remembering to take medication), failures of output monitoring can result in repetitions and omissions of planned actions (e.g., over- or under-medication). To be successful in output monitoring paradigms, participants must flexibly control attention to detect PM cues as well as engage controlled retrieval of previous actions whenever a particular cue is encountered. The current study examined individual differences in output monitoring abilities in a group of younger adults differing in attention control (AC) and episodic memory (EM) abilities. The results showed that AC ability uniquely predicted successful cue detection on the first presentation, whereas EM ability uniquely predicted successful output monitoring on the second presentation. The current study highlights the importance of examining external correlates of PM abilities and contributes to the growing body of research on individual differences in PM.

  7. Individual air pollution monitors. 2. Examination of some nonoccupational research and regulatory uses and needs

    Energy Technology Data Exchange (ETDEWEB)

    Morgan, M.G.; Morris, S.C.

    1977-01-01

    Knowledge of the relationship between ambient air pollution levels measured at fixed monitoring stations and the actual exposure of the population is very limited. Indeed, there is rapidly growing evidence that fixed-station monitors do not provide adequate data for population exposure. This report examines available data for carbon monoxide (CO) and sulfur dioxide (SO/sub 2/) and presents a new analysis. Actual population exposure to CO appears to be consistently higher than expected from fixed-station data, while limited evidence suggests that exposures to SO/sub 2/ are lower. A reported general relationship between indoor and outdoor levels of SO/sub 2/ is not supported by the data. If air pollution represents a threat to public health, then more attention must be given to total population exposure to pollutants. A selective use of individual air pollution monitors that can be worn or carried appears to be required at some stage by any experimental design seeking to uncover the relation between air pollution exposure and health effects. Additionally, potential uses of individual monitoring in air pollution regulation are explored. Current status and research needs for individual air pollution monitors are examined and a first-order evaluation is given of the promise held by the candidate instrumentation technologies. A national program of support for the development of individual air pollution monitors is recommended.

  8. Individual Self-monitoring &Peer-monitoring In One Classroom in Writing Activities: Who Is at Disadvantage?

    Directory of Open Access Journals (Sweden)

    Zohreh Zare Toofan

    2014-02-01

    Full Text Available Writing is an important experience through which we are able to share ideas, arouse feelings, persuade and convince other people (white & Arndt, 1991. It is important to view writing not solely as the product of an individual, but as a cognitive, social and cultural act. Writing is an act that takes place within a context, that accomplishes a particular purpose and that is appropriately shaped for its intended audience (Hamplyones & Condon, 1989. Here, the present research considers the significance effects of two important independent variables self-monitoring and peer-monitoring in writing activities on Iranian EFL learners. In this research it was supposed to study new effects of two Meta cognitive strategies self-monitoring and peer-monitoring on 173 male and female learners' writing activities whose age ranged between the age 16-27, and they had a composing description writing paragraph as pre & post test in the same conditions. Although many studies have been conducted on the effects of self-monitoring with a variety of students across a variety of settings (Amato-Zech, Hoff, & Doepke, 2006 Cooper et al., 2007, Dunlap, Dunlap, Koegel, & Koegel 1991. But goal of this study was to increase the participant’s on-task behavior in self & peer-monitoring (E. Johnson, 2007, Self &Peer-monitoring added. Although both of them were useful for providing challengeable students, and became useful for prosocial life, but self-monitoring helped them to become awareness of their weaknesses and strengths to increase positive way of the quality and quantity of their learning in written task, and peer-monitoring occurred when the students achieved recognition level to evaluate the other peers' behavior, and it was obviously understood that it needed more training time to arrive at the level of recognition of each others' behavior.

  9. Borehole logging in uranium exploration

    International Nuclear Information System (INIS)

    Kulkarni, N.H.

    1992-01-01

    The ultimate objective of exploration by drilling as far as Atomic Minerals Division is concerned is to locate the ore zone in the subsurface, draw samples and analyze them for their metal content. The presence of the ore zone is also indicated by gamma-ray logging of the borehole. A gamma-ray detector is lowered in the borehole and precise depth and grade of the ore zone is established. This helps the geologist in correlating the ore horizon with the surface outcrop or the ore zone intercepted in adjoining boreholes and in deciding about further drilling and location of boreholes. Most commonly, total gamma measurements are made although some units capable of measuring the gamma-ray spectrum are also in use. It is possible to know if the mineralization is due to uranium without waiting for the laboratory results. The present write up gives a brief account of the principles, equipment and methods of borehole gamma-ray logging including density and self-potential logging. (author). 8 refs., 5 figs

  10. First assessment of individual monitoring of medical workers occupationally exposed to ionizing radiation in Burkina Faso

    International Nuclear Information System (INIS)

    Yakoro, A.; Nobila Ouédraogo, Salimata Traoré

    2010-01-01

    This paper reports the results of monitoring of medical workers occupationally exposed to ionizing radiation as a consequence of exposure to X-rays, from 2007 to 2010, in Burkina Faso. The radiation exposure monitoring was made with thermoluminescent dosimeters (TLD-100) type 0110 and the reader used was Harshaw 4500. The medical establishments. subscribers were provided with personal dosimeters (measuring Hp (10) and Hp (0.07)) and dosimeters for background and workplace exposure (H*10) measurement. The dosimeters have been worn for periods of 2 months each. The number of establishments subscribed and workers monitored has gradually increased from 4 radiology establishments with 13 workers monitored at September 2007 to 23 subscribers with 121 workers monitored at the end of April 2010. 13 establishments were still working without monitoring. From September 2007 to April 2010, no individual annual dose limit has really been reached. 88.16% of the 2 months dose values of personal dosimeters were below 0.1mSv, the detection limit and 96.61% of Hp (10) bimonthly values were below 3.33mSv. The workplace exposure monitoring values were often low (varying from 0.00mSv to 40.45mSv). 87.08% of the values of H*(10) were below 3.33mSv, the upper limit of Hp (10) for a period of 2 months. Low values of individual dose have also been recorded despite of high values of workplace monitoring. This allowed to state that the workers monitored were not exposed to a major risk. Nevertheless, 13 TLD have been lost and 3 damaged by subscribers (out of 1504 TLD provided). 26 times (out of 240), background measurement and workplace exposure monitoring dosimeters have been placed at the improper location. Therefore, sensitization of the establishments using ionizing radiation should be reinforced and the national regulations should impose radiation monitoring (author)

  11. Stratigraphy of the Harwell boreholes

    International Nuclear Information System (INIS)

    Gallois, R.W.; Worssam, B.C.

    1983-12-01

    Seven boreholes, five of them partially cored, were drilled at the Atomic Energy Research Establishment at Harwell as part of a general investigation to assess the feasibility of storing low- and intermediate-level radioactive waste in underground cavities. Two of the deeper boreholes were almost wholly cored to provide samples for hydrogeological, hydrochemical, mineralogical, geochemical, geotechnical, sedimentological and stratigraphical studies to enable variations in lithology and rock properties to be assessed, both vertically and laterally, and related to their regional geological setting. This report describes the lithologies, main faunal elements and stratigraphy of the Cretaceous, Jurassic, Triassic and Carboniferous sequences proved in the boreholes. More detailed stratigraphical accounts of the late Jurassic and Cretaceous sequences will be prepared when current studies of the faunal assemblages are complete. (author)

  12. Cognitive Abilities, Monitoring Confidence, and Control Thresholds Explain Individual Differences in Heuristics and Biases.

    Science.gov (United States)

    Jackson, Simon A; Kleitman, Sabina; Howie, Pauline; Stankov, Lazar

    2016-01-01

    In this paper, we investigate whether individual differences in performance on heuristic and biases tasks can be explained by cognitive abilities, monitoring confidence, and control thresholds. Current theories explain individual differences in these tasks by the ability to detect errors and override automatic but biased judgments, and deliberative cognitive abilities that help to construct the correct response. Here we retain cognitive abilities but disentangle error detection, proposing that lower monitoring confidence and higher control thresholds promote error checking. Participants ( N = 250) completed tasks assessing their fluid reasoning abilities, stable monitoring confidence levels, and the control threshold they impose on their decisions. They also completed seven typical heuristic and biases tasks such as the cognitive reflection test and Resistance to Framing. Using structural equation modeling, we found that individuals with higher reasoning abilities, lower monitoring confidence, and higher control threshold performed significantly and, at times, substantially better on the heuristic and biases tasks. Individuals with higher control thresholds also showed lower preferences for risky alternatives in a gambling task. Furthermore, residual correlations among the heuristic and biases tasks were reduced to null, indicating that cognitive abilities, monitoring confidence, and control thresholds accounted for their shared variance. Implications include the proposal that the capacity to detect errors does not differ between individuals. Rather, individuals might adopt varied strategies that promote error checking to different degrees, regardless of whether they have made a mistake or not. The results support growing evidence that decision-making involves cognitive abilities that construct actions and monitoring and control processes that manage their initiation.

  13. Cognitive abilities, monitoring, and control explain individual differences in heuristics and biases

    Directory of Open Access Journals (Sweden)

    Simon Anthony Jackson

    2016-10-01

    Full Text Available In this paper, we investigate whether individual differences in performance on heuristic and biases tasks can be explained by cognitive abilities, monitoring confidence and control thresholds. Current theories explain individual differences in these tasks by the ability to detect errors and override automatic but biased judgements, and deliberative cognitive abilities that help to construct the correct response. Here we retain cognitive abilities but disentangle error detection, proposing that lower monitoring confidence and higher control thresholds promote error checking. Participants (N = 250 completed tasks assessing their fluid reasoning abilities, stable monitoring confidence levels, and the control threshold they impose on their decisions. They also completed seven typical heuristic and biases tasks such as the cognitive reflection test and resistance to framing. Using structural equation modelling, we found that individuals with higher reasoning abilities, lower monitoring confidence and higher control threshold performed significantly and, at times, substantially better on the heuristic and biases tasks. Individuals with higher control thresholds also showed lower preferences for risky alternatives in a gambling task. Furthermore, residual correlations among the heuristic and biases tasks were reduced to null, indicating that cognitive abilities, monitoring confidence and control thresholds accounted for their shared variance. Implications include the proposal that the capacity to detect errors does not differ between individuals. Rather, individuals might adopt varied strategies that promote error checking to different degrees, regardless of whether they have made a mistake or not. The results support growing evidence that decision making involves cognitive abilities that construct actions and monitoring and control processes that manage their initiation.

  14. Monitoring of individual doses and its information management system for CAEP's employees

    International Nuclear Information System (INIS)

    Wei Xiye; Lei Jiarong; Yuan Yonggang; Zhao Lin; Zhao Minzhi; Cui Gaoxian

    2007-01-01

    Employees' individual dose is very important to radiation workers, this paper introduces the monitoring of individual doses for the employees of CAEP in brief. A mass of employees' individual dose information records needed for being disposed, the data management software IDDMS for individual dose was developed. This paper describes the database structure, main modules, statistic and printing functions in this program. Based on much experience of many years in data management of individual dose, this program is developed using the object-oriented language Visual Foxpro 6.0. Meanwhile, it had been tested for several months. The results show that this software can be used directly for daily management of individual dose, and report forms of individual dose can also be printed easily for the related superior department. (authors)

  15. A Review of the New European Technical Recommendations for Monitoring Individuals Occupationally Exposed to External Radiation

    International Nuclear Information System (INIS)

    Dijk, J.W.E. van; Alves, J.G.; Ambrosi, P.; Bartlett, D.T.; Currivan, L.; Fantuzzi, E.; Kamenopoulou, V.

    2013-01-01

    This paper reviews the revised Technical Recommendations for Monitoring Individuals Occupationally Exposed to External Radiation as issued by the European Commission as Radiation Protection 160. These recommendations are aimed at all stakeholders in radiation protection dosimetry with an emphasis in the responsible technical staff of approved dosimetry services. This paper briefly touches each Chapter and ends with a more in depth section on the uncertainty evaluation of dose measurements. -- Highlights: ► Recommendations on all aspects of running an approved dosimetry service. ► Radiation protection framework. ► Metrology of personal dosimeters. ► QC and QA of individual monitoring

  16. Evaluation of performance of electronic dosimeters for individual monitoring: tests in laboratory

    International Nuclear Information System (INIS)

    Garzon, W.J.; Khoury, H.J.; Barros, V.S.M. de; Medeiros, R.B.

    2015-01-01

    Electronic dosimeters based on direct ion storage technology are being widely used in many countries for individual monitoring in many applications of ionizing radiation. However, their use as routine dosimeter has been established in a few countries due to lack of accreditation or intercomparison programs. The objective of this study is to evaluate the performance of two direct íon storage dosimeters model available in the international market: the Miriom-Instadose-1 and RADOS DIS-1 to be eventually accepted for individual monitoring in Brazil. (author)

  17. Utility service entrance in boreholes

    International Nuclear Information System (INIS)

    1987-08-01

    This study evaluates alternatives for utility service entrances to the repository. We determined the requirements for a repository utility supply. These requirements were defined as safety, maintainability, flexibility, reliability, cost efficiency, voltage regulation, and simplicity of operation. The study showed that repository shafts can best satisfy all requirements for location of the utility supply without the use of borehole penetrations into the repository. It is recommended that the shafts be utilized for utility distribution to the repository, and that the current NWTS program position to minimize the number of boreholes penetrating the repository horizon be maintained. 42 refs., 2 figs., 3 tabs

  18. Radiometric calipers for borehole logging

    International Nuclear Information System (INIS)

    Charbucinski, J.; Wylie, A.W.; Jarrett, R.G.

    1976-01-01

    Two versions of a radiometric-type caliper for measuring borehole diameter are described. One, based on the bow-spring principle, is suitable for percussion (exploration) drill holes. The other, which utilizes hemispherical wall contactors actuated by springs, is suitable for blast holes. Both utilize low-power radioactive sources and employ a scintillation detector to measure the 'inverse-square law' response of the device to changes in borehole radius. The performance of the device is examined and examples of its use are illustrated. (author)

  19. Method and apparatus for logging inclined earth boreholes

    International Nuclear Information System (INIS)

    Youmans, A.H.

    1981-01-01

    An improved technique is provided for comparing the velocity of an elongated well logging instrument traversing an inclined earth borehole with the playout velocity of the well logging cable at the earth's surface to control both the cable hoist drum rotation and the rate of movement of the subsurface instrument and thus insure cable playout is in equilibrium with the logging instrument movement. Method and apparatus are described for detecting any reduction in movement of the logging instrument through the borehole and for reducing the velocity of the logging cable playout in response thereto by reducing drum rotation. Further, when the velocity of cable playout slows to a preselected value, a monitoring circuit generates control signals which actuate a means of power attached to or integral with the logging instrument which, upon initiation, apply a force to move the logging instrument upward or downward within the borehole

  20. Individual radiological monitoring for exposed personnel of Nuclear Fuel Plant at Pitesti

    International Nuclear Information System (INIS)

    Ivana, T.; Epure, Gh.

    2010-01-01

    In the activity of nuclear fuel fabrication of CANDU type, based on natural and depleted uranium, individual radiological monitoring of the personnel exposed to ionizing radiation is very carefully approached. For Nuclear Fuel Plant (NFP) facility, where uranium appears in bulk and itemized form, measures for individual radiological monitoring are established by Radiological Safety Manual (MSR) in accordance with national and international legislation. All NFP employees are classified in either category A or category B of exposure to ionizing radiation. The classification is a function of type of activity and magnitude of exposure. All the exposed personnel are monitored for external doses (from gamma radiation) by measuring the equivalent dose H p (10) with monthly frequency. The system used for external individual dosimetric monitoring is based on the thermoluminescent dosimeter (TLD) of PANASONIC type UD813AS14. The NFP incorporates an in-house dosimetric laboratory notified by Romanian regulatory body CNCAN (National Commission for Control of Nuclear Activities). The workers handling nuclear materials are exposed to internal intake of uranium, mainly by inhalation. For internal doses monitoring is included part of exposed employees working directly with radioactive open sources (pulverulent or liquid nuclear materials), UO 2 sinterable powder, green pellets, sintered pellets, scrap and radioactive effluents. The estimation of internal exposure is made quarterly using the results from radioactive airborne monitors operating in the working places. The internal dose of each person exposed to open sources is calculated taking into account the rate of breathing, the time spent at the work place and the dose-activity coefficient (variable function of uranium absorption rate). The total effective individual dose is obtained by summing the external dose and internal dose (E=E ext +E int ). For conformity, the total effective individual dose (E) is compared with dose

  1. Borehole data package for the 100-K area ground water wells, CY 1994

    International Nuclear Information System (INIS)

    Williams, B.A.

    1994-01-01

    Borehole, hydrogeologic and geophysical logs, drilling, as-built diagrams, sampling, and well construction information and data for RCRA compliant groundwater monitoring wells installed in CY 1994 at the 100-K Basins

  2. Harmonisation and dosimetric quality assurance in individual monitoring for external radiation

    DEFF Research Database (Denmark)

    Bartlett, D.T.; Ambrosi, P.; Back, C.

    2001-01-01

    The current situation amongst Member States is that there are widely differing national requirements for dosimetric services and for dosemeter performance. It is clear that with the free movement of workers within the European Union (EU) and the requirements for individual dosimetry given...... of individual monitoring using personal dosemeters and assisting movement towards harmonised procedures. An outline of the work of the action group is given and the term 'harmonisation' is discussed....

  3. Self-monitoring of blood glucose in diabetes mellitus: arguments for an individualized approach.

    Science.gov (United States)

    Nauck, Michael A; El-Ouaghlidi, Andrea; Vardarli, Irfan

    2009-09-01

    The utility of glucose self-monitoring in different types and stages of diabetes is controversial, as there is only sparse relevant evidence from randomized controlled clinical trials. In this analysis, the authors aim to develop individualized recommendations based on clinical needs and the available literature. The PubMed database was searched for articles that appeared up to 30 September 2008 containing the terms "measurement," "control","monitoring," and "hypoglycemia"; the retrieved articles were supplemented by other articles that were cited in them. A directed search was also made for the recommendations of the German, European, American, and international diabetological societies. Conclusions were then drawn about the useful modalities and extent of glucose self-monitoring on the basis of the clinical features of the major types of diabetes and the main treatment strategies for them. With the exception of intensified treatment strategies (which rely on blood-sugar regulation with insulin), only a few evidence-based recommendations can be derived from randomized clinical trials and meta-analyses. Nonetheless, a strategy for self-monitoring according to the patient's individual needs can be derived from the characteristics of therapeutic regimens: depending on the type of diabetes from which the patient suffers, the predicted number of glucometer strips required for self-monitoring will vary from almost none to roughly 400 per month. The decision to use glucose self-monitoring, as well as the type and extent of self-monitoring that will be used, should be based on the individual patient's type of diabetes, treatment regimen, and clinical characteristics. Like any other type of therapeutic intervention, self-monitoring should have a well-documented, rational justification.

  4. Individual Differences in Search and Monitoring for Color Targets in Dynamic Visual Displays.

    Science.gov (United States)

    Muhl-Richardson, Alex; Godwin, Hayward J; Garner, Matthew; Hadwin, Julie A; Liversedge, Simon P; Donnelly, Nick

    2018-02-01

    Many real-world tasks now involve monitoring visual representations of data that change dynamically over time. Monitoring dynamically changing displays for the onset of targets can be done in two ways: detecting targets directly, post-onset, or predicting their onset from the prior state of distractors. In the present study, participants' eye movements were measured as they monitored arrays of 108 colored squares whose colors changed systematically over time. Across three experiments, the data show that participants detected the onset of targets both directly and predictively. Experiments 1 and 2 showed that predictive detection was only possible when supported by sequential color changes that followed a scale ordered in color space. Experiment 3 included measures of individual differences in working memory capacity (WMC) and anxious affect and a manipulation of target prevalence in the search task. It found that predictive monitoring for targets, and decisions about target onsets, were influenced by interactions between individual differences in verbal and spatial WMC and intolerance of uncertainty, a characteristic that reflects worry about uncertain future events. The results have implications for the selection of individuals tasked with monitoring dynamic visual displays for target onsets. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  5. Individual monitoring of external exposure in terms of personal dose equivalent, Hp(d)

    International Nuclear Information System (INIS)

    Fantuzzi, E.

    2001-01-01

    The institute for Radiation Protection of ENEA - Bologna has organised a one day-workshop on the subject: Individual monitoring of external exposure in terms of personal dose equivalent, H p (d). The aim of the workshop was the discussion of the new implications and modifications to be expected in the routine individual monitoring of external radiation, due to the issue of the Decree 241/00 (G.U. 31/8/2000) in charge since 01/01/2001. The decree set up in Italian law the standards contained in the European Directive EURATOM 96/29-Basic Standards for the Protection of Health of Workers and the General Public against Dangers arising from Ionizing Radiation. Among others, the definition of the operational quantities for external radiation for personal and environmental monitoring, H p (d) e H * (d) respectively as defined by ICRU (International Commission for Radiation Units and Measurements), requires to update the methods of measurements and calibration of the personal dosemeters and environmental monitors. This report collects the papers presented at the workshop dealing with the Personal Dose Equivalent, H p (d), the conversion coefficients, H p (d)/K a e H p (d)/ , obtained through Monte Carlo calculations published by ICRU and ICRP (International Commission for Radiation Protection), the new calibration procedures and the practical implication in the routine of individual monitoring in terms of H p (d). Eventually, in the last chapter, the answers to Frequently Asked Questions (FAQ) are briefly reported [it

  6. Development and characterization of two-component albedo based neutron individual monitoring system using thermoluminescent detectors

    International Nuclear Information System (INIS)

    Martins, Marcelo Marques

    2008-01-01

    A TLD-albedo based two-component neutron individual monitoring system was developed and characterized in this work. The monitor consists of a black plastic holder, an incident neutron boron loaded shield, a moderator polyethylene body (to increase its response), two pairs of TLD-600 and TLD-700 (one pair to each component) and an adjustable belt. This monitoring system was calibrated in thermal neutron fields and in 70 keV, 144 keV, 565 keV, 1.2 MeV and 5 MeV monoenergetic neutron fields. In addition, it was calibrated in 252C f(D 2 O), 252 Cf, 241 Am-B, 241 Am-Be and 238 Pu-Be source fields. For the latter, the lower detection levels are, respectively, 0.009 mSv, 0.06 mSv, 0.12 mSv, 0.09 mSv and 0.08 mSv. The participation in an international intercomparison sponsored by IAEA with simulated workplace fields validated the system. The monitoring system was successfully characterized in the ISO 21909 standard and in an IRD - the Brazilian Institute for Radioprotection and Dosimetry - technical regulation draft. Nowadays, the neutron individual system is in use by IRD for whole body individual monitoring of five institutions, which comprehend several activities. (author)

  7. Quality Assurance for a TLD Based Individual Monitoring Service (invited paper)

    Energy Technology Data Exchange (ETDEWEB)

    Julius, H.W.; Van Dijk, J.W.E. [Arnhem (Netherlands)

    1999-07-01

    Approved Individual Monitoring Services should, in addition to complying with specific national performance requirements, also have implemented a quality assurance (QA) and quality control (QC) programme as an integral part of the operation. Essential elements of a QA/QC programme are discussed. Some practical hints and examples of QA practices are given, focussing on the application of thermoluminescence dosimetry. (author)

  8. Individual Differences in Working Memory Capacity Predict Action Monitoring and the Error-Related Negativity

    Science.gov (United States)

    Miller, A. Eve; Watson, Jason M.; Strayer, David L.

    2012-01-01

    Neuroscience suggests that the anterior cingulate cortex (ACC) is responsible for conflict monitoring and the detection of errors in cognitive tasks, thereby contributing to the implementation of attentional control. Though individual differences in frontally mediated goal maintenance have clearly been shown to influence outward behavior in…

  9. Radiological protection. Technical recommendations for monitoring the exposure of individuals to external radiation

    International Nuclear Information System (INIS)

    1975-01-01

    Advice is given on the assessment of personal doses received by each worker. The objectives of individual monitoring programs and the requirements which personal dosemeters should satisfy are given. The paper is mainly concerned with assessment of doses due to photon and electron radiations

  10. Implantation of a new certification systematic of external individual monitoring services in Brazil

    International Nuclear Information System (INIS)

    Salati, Ivan P.A.; Cunha, Paulo G. da; Mauricio, Claudia L.P.; Mota, Helvecio C.; Ramos, Manoel M.O.; Silva, Teogenes A. da

    1996-01-01

    Brazilian regulations for External Individual Monitoring Services (SMIE) were established since 1981 and they weren't able to accomplish that these services reached the standards of quality assurance programs appointed for both national and international recommendations. Intercomparisons and audits took in course in 80's showed the necessity of improving the quality of services operating in Brazil. These services are responsible for monitoring more than 40.000 workers in this country. In 1992, the Committee of Assessment of External Individual Monitoring (named CASMIE) was created in the Instituto de Radioprotecao e Dosimetria (IRD/CNEN) in the aim of developing technical standards and to propose new procedures of SMIEs accreditation by Comissao Nacional de Energia Nuclear (CNEN). The new procedures are implemented in 1995. In this work, the relevant aspects of this process are presented, as well as a summary of the technical documents that were developed by CASMIE. (author)

  11. Waste Isolation Pilot Plant borehole data

    International Nuclear Information System (INIS)

    1995-04-01

    Data pertaining to all the surface boreholes used at the WIPP site for site characterization hydrological testing and resource evaluation exist in numerous source documents. This project was initiated to develop a comprehensive data base that would include the data on all WIPP related surface boreholes from the Atomic Energy Commission, Waste Isolation Pilot Plant Energy Research and Development Administration, Department of Energy, and Hydrologic Test Borehole Programs. The data compiled from each borehole includes: operator, permit number, location, total depth, type of well, driller, drilling record, casing record, plugging schedule, and stratigraphic summary. There are six groups of boreholes contained in this data base, they are as follows: Commercially Drilled Potash Boreholes, Energy Department Wells, Geologic Exploration Boreholes, Hydrologic Test Boreholes, Potash Boreholes, and Subsurface Exploration Boreholes. There were numerous references which contained borehole data. In some cases the data found in one document was inconsistent with data in another document. In order to ensure consistency and accuracy in the data base, the same references were used for as many of the boreholes as possible. For example, all elevations and locations were taken from Compilation and Comparison of Test-Hole Location Surveys in the Vicinity of the WIPP Site. SAND 88-1065, Table 3-5. There are some sections where a data field is left blank. In this case, the information was either not applicable or was unavailable

  12. Waste Isolation Pilot Plant borehole data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    Data pertaining to all the surface boreholes used at the WIPP site for site characterization hydrological testing and resource evaluation exist in numerous source documents. This project was initiated to develop a comprehensive data base that would include the data on all WIPP related surface boreholes from the Atomic Energy Commission, Waste Isolation Pilot Plant Energy Research and Development Administration, Department of Energy, and Hydrologic Test Borehole Programs. The data compiled from each borehole includes: operator, permit number, location, total depth, type of well, driller, drilling record, casing record, plugging schedule, and stratigraphic summary. There are six groups of boreholes contained in this data base, they are as follows: Commercially Drilled Potash Boreholes, Energy Department Wells, Geologic Exploration Boreholes, Hydrologic Test Boreholes, Potash Boreholes, and Subsurface Exploration Boreholes. There were numerous references which contained borehole data. In some cases the data found in one document was inconsistent with data in another document. In order to ensure consistency and accuracy in the data base, the same references were used for as many of the boreholes as possible. For example, all elevations and locations were taken from Compilation and Comparison of Test-Hole Location Surveys in the Vicinity of the WIPP Site. SAND 88-1065, Table 3-5. There are some sections where a data field is left blank. In this case, the information was either not applicable or was unavailable.

  13. Dynamic monitoring of weight data at the pen vs at the individual level

    DEFF Research Database (Denmark)

    Jensen, Dan; Toft, Nils; Kristensen, A. R. K.

    recorded weight data from finisher pigs. Data are collected at insertion and at the exit of the first pigs in the pen, and in few pens, the weight is recorded weekly. Dynamic linear models are fitted on the weight data, at the pig level (univariate), at the double pen level using averaged weight...... (univariate) and using individual pig values as parameters in a hierarchical (multivariate) model including section, double pen, and individual level. Variance components of the different models are estimated using the Expectation Maximization algorithm. The difference of information obtained...... at the individual vs pen level is thereafter assessed. Whereas weight data is usually monitored after a batch is being sent to the slaughter house, this method provides weekly updating of the data. Perspectives of application include dynamic monitoring of weight data in relation to events such as diarrhoea, tail...

  14. Dynamic monitoring of weight data at the pen vs at the individual level

    DEFF Research Database (Denmark)

    Jensen, Dan Børge; Toft, Nils; Kristensen, Anders Ringgaard

    recorded weight data from finisher pigs. Data are collected at insertion and at the exit of the first pigs in the pen, and in few pens, the weight is recorded weekly. Dynamic linear models are fitted on the weight data, at the pig level (univariate), at the double pen level using averaged weight...... (univariate) and using individual pig values as parameters in a hierarchical (multivariate) model including section, double pen, and individual level. Variance components of the different models are estimated using the Expectation Maximization algorithm. The difference of information obtained...... at the individual vs. pen level is thereafter assessed. Whereas weight data is usually monitored after a batch is being sent to the slaughter house, this method provides with weekly updating of the data. Perspectives of application include dynamic monitoring of weight data in relation to events such as diarrhoea...

  15. Monitoring and assessment of individual doses of occupationally exposed workers due to intake of radionuclides

    International Nuclear Information System (INIS)

    Alexander, O. A.

    2014-04-01

    Monitoring and estimation of individual intakes of radionuclides can be complex. Doses of intakes cannot be measured directly, however must be assessed from the monitoring data of the individual. The individual monitoring data includes whole body counting, excretion analysis (urine or faecal). In the estimation of these data requires that the assessor makes assumptions about the exposure scenario, including the pattern and mode of radionuclide intake. Also physicochemical characteristics of the material involved and the period of time between exposure and measurement. This project report seeks to provide some underlying guidance on monitoring programmes and data interpretation using case study. In this present study the committed effective dose (CED) 1.20mSv exceeded the recording level (i.e. 1mSv) however it was below the investigation level (i.e. 2mSv). The present study recommends that as an essential part in internal dosimetry, specialists be capable of recognizing conditions warranting follow-up bioassay and dose evaluation. Personnel should be familiar with the relevant internal dosimetry literature and the recommendations of national and international scientific organizations with regard to internal dose. (au)

  16. Automated read-out of thermoluminescence dosemeters in a centralized individual monitoring service

    International Nuclear Information System (INIS)

    Toivonen, M.

    The organizational problems in maintaining centralized individual monitoring service with erasable and re-usable dosemeters are evaluated. Design criteria for an automated thermoluminescence reader are laid down. It is characteristic for the planning of the monitoring system that the issuing of dosemeters can be arranged without having two dosemeters for each worker. A home made reader designed to fullfil these criteria is presented. The use of a standard barcode and a standard optical barcode reader in identification of dosemeters is described. A method of using a minicomputer in preparing the self-fastening identification labels, in printing mailing lists and in printing results is described

  17. Working program for deep borehole investigations. HDB-6,7,8, borehole

    International Nuclear Information System (INIS)

    Hama, Katsuhiro; Takahashi, Kazuharu; Ishii, Eiichi; Takeuchi, Ryuji; Sasaki, Manabu; Kunimaru, Takanori; Eki, Nobuhiro; Matsui, Hiroya

    2003-08-01

    optimized program for deep borehole (HDB-6, 7, 8) investigations has been drawn-up. This program addresses the general issues and provides input to the subsequent investigation programs and design for the shaft and experimental drifts. This document mainly describes the planned working program for the HDB-6, 7, 8 borehole investigations including associated laboratory programs during and after drilling. The working program is divided into the following investigation fields: borehole drilling geology, geophysics, hydrogeology, hydrochemistry, rock mechanics and long-term monitoring. Post-HDB borehole investigations; a VSP (Vertical Seismic Profiling) survey are planned in the surface-based investigations phase. (author)

  18. Automated borehole gravity meter system

    International Nuclear Information System (INIS)

    Lautzenhiser, Th.V.; Wirtz, J.D.

    1984-01-01

    An automated borehole gravity meter system for measuring gravity within a wellbore. The gravity meter includes leveling devices for leveling the borehole gravity meter, displacement devices for applying forces to a gravity sensing device within the gravity meter to bring the gravity sensing device to a predetermined or null position. Electronic sensing and control devices are provided for (i) activating the displacement devices, (ii) sensing the forces applied to the gravity sensing device, (iii) electronically converting the values of the forces into a representation of the gravity at the location in the wellbore, and (iv) outputting such representation. The system further includes electronic control devices with the capability of correcting the representation of gravity for tidal effects, as well as, calculating and outputting the formation bulk density and/or porosity

  19. The Antartic Ice Borehole Probe

    Science.gov (United States)

    Behar, A.; Carsey, F.; Lane, A.; Engelhardt, H.

    2000-01-01

    The Antartic Ice Borehole Probe mission is a glaciological investigation, scheduled for November 2000-2001, that will place a probe in a hot-water drilled hole in the West Antartic ice sheet. The objectives of the probe are to observe ice-bed interactions with a downward looking camera, and ice inclusions and structure, including hypothesized ice accretion, with a side-looking camera.

  20. Comparisons between direct ion storage and thermoluminescence dosimetry individual monitoring systems, and internet reporting

    International Nuclear Information System (INIS)

    Kiuru, A.; Kahilainen, J.; Hyvoenen, H.; Vartiainen, E.

    2001-01-01

    A new electronic direct ion storage (DIS) dosemeter allows accumulated personal dose equivalent H p (d) at depths of 10 mm and 0.07 mm to be monitored in a few seconds by inserting the dosemeter into a local reader without deleting the accumulated dose. The DIS system meets general requirements on individual monitoring of hospital personnel using ionising radiation. It differs greatly from off-line thermoluminescence dosimetry systems and offers many additional benefits. The non-volatile reading takes only 5 s, is taken as often as needed, and the data are collected into a dose database, where background radiation is subtracted. Individual personnel doses are reported in Intranet as well as on the Internet at regular intervals to the National Regulatory Authorities. (author)

  1. The Key to Individualized Addiction Treatment is Comprehensive Assessment and Monitoring of Symptoms and Behavioral Change

    Directory of Open Access Journals (Sweden)

    Thomas F. Hilton

    2015-10-01

    Full Text Available Modern health services now strive for individualized treatment. This approach has been enabled by the increase in knowledge derived from neuroscience and genomics. Substance use disorders are no exception to individualized treatment even though there are no gene-specific medications yet available. What is available is the ability to quickly and precisely assess and monitor biopsychosocial variables known to vary during addiction recovery and which place addicts at increased risk of relapse. Monitoring a broad spectrum of biopsychosocial health enables providers to address diverse genome-specific changes that might trigger withdrawal from treatment or recovery relapse in time to prevent that from occurring. This paper describes modern measurement tools contained in the NIH Patient-Reported Outcomes Measurement Information System (PROMIS and the NIH Toolbox and suggests how they might be applied to support recovery from alcohol and other substance use disorders in both pharmacological and abstinence-oriented modalities of care.

  2. Exploratory boreholes Juchlistock-Grimsel

    International Nuclear Information System (INIS)

    Mueller, W.; Keusen, H.R.

    1981-11-01

    The aim of the investigation was the completion of missing geological, hydrogeological and rock-mechanical data about a suitable site for the intended Nagra rock laboratory at Grimsel. To this aim, 6 horizontal boreholes of 100 m length and 86 mm diameter were drilled. The cores, extracted practically without loss, and mechanical data for the main investigation was an extensive evaluation of the lithographic discontinuities and anisotropies, because they are the main determinant of the hydrogeological conditions of the locality. The area is dominated by granites and granodiorite which are of variable biotite content, lamprophyres and aplites. The largest part of the investigated mountain region consists of compact unclefted rock. 478 of the 600 bore meters, i.e. about 80 % of the drilled mountain, have no open clefts. Only 22 of the 600 bore meters (3.6 %0 contain more than five clefts per meter, at which the open clefts in the boreholes SB1 and SB5 appear more frequently. At the remaining exploratory boreholes in 90 % of the mountain ther are no open clefts. 15 refs., 52 figs., 15 tabs

  3. Study of Commercial Bank Risk Monitoring Model in Individual Consumption Credit

    Institute of Scientific and Technical Information of China (English)

    刘春红

    2003-01-01

    With the development of individual consumption credit (ICC) in China, commercial banks have been exposed to more and more risks. The loan failure has been an important problem that the banking must face and revolve. This paper develops a factor system to explain how the borrower's risk is affected, and then establishes a risk monitoring model with AHP to pre-warn the banks how much the risk is.

  4. Individual aircraft life monitoring: An engineering approach for fatigue damage evaluation

    Directory of Open Access Journals (Sweden)

    Rui JIAO

    2018-04-01

    Full Text Available Individual aircraft life monitoring is required to ensure safety and economy of aircraft structure, and fatigue damage evaluation based on collected operational data of aircraft is an integral part of it. To improve the accuracy and facilitate the application, this paper proposes an engineering approach to evaluate fatigue damage and predict fatigue life for critical structures in fatigue monitoring. In this approach, traditional nominal stress method is applied to back calculate the S-N curve parameters of the realistic structure details based on full-scale fatigue test data. Then the S-N curve and Miner’s rule are adopted in damage estimation and fatigue life analysis for critical locations under individual load spectra. The relationship between relative small crack length and fatigue life can also be predicted with this approach. Specimens of 7B04-T74 aluminum alloy and TA15M titanium alloy are fatigue tested under two types of load spectra, and there is a good agreement between the experimental results and analysis results. Furthermore, the issue concerning scatter factor in individual aircraft damage estimation is also discussed. Keywords: Fatigue damage, Fatigue monitoring, Fatigue test, Scatter factor, S-N curve

  5. Borehole Stability in High-Temperature Formations

    Science.gov (United States)

    Yan, Chuanliang; Deng, Jingen; Yu, Baohua; Li, Wenliang; Chen, Zijian; Hu, Lianbo; Li, Yang

    2014-11-01

    In oil and gas drilling or geothermal well drilling, the temperature difference between the drilling fluid and formation will lead to an apparent temperature change around the borehole, which will influence the stress state around the borehole and tend to cause borehole instability in high geothermal gradient formations. The thermal effect is usually not considered as a factor in most of the conventional borehole stability models. In this research, in order to solve the borehole instability in high-temperature formations, a calculation model of the temperature field around the borehole during drilling is established. The effects of drilling fluid circulation, drilling fluid density, and mud displacement on the temperature field are analyzed. Besides these effects, the effect of temperature change on the stress around the borehole is analyzed based on thermoelasticity theory. In addition, the relationships between temperature and strength of four types of rocks are respectively established based on experimental results, and thermal expansion coefficients are also tested. On this basis, a borehole stability model is established considering thermal effects and the effect of temperature change on borehole stability is also analyzed. The results show that the fracture pressure and collapse pressure will both increase as the temperature of borehole rises, and vice versa. The fracture pressure is more sensitive to temperature. Temperature has different effects on collapse pressures due to different lithological characters; however, the variation of fracture pressure is unrelated to lithology. The research results can provide a reference for the design of drilling fluid density in high-temperature wells.

  6. Catalog of borehole lithologic logs from the 600 Area, Hanford Site

    International Nuclear Information System (INIS)

    Fecht, K.R.; Lillie, J.T.

    1982-03-01

    Rockwell Hanford Operations (Rockwell) geoscientists are studying the Hanford Site subsurface environment to assure safe management operations, disposal, and storage of radioactive waste. As part of this effort, geoscientists have collected geotechnical data from about 3000 boreholes drilled on the Hanford Site since the early 1900s. These boreholes have been used for subsurface geologic, hydrologic, and engineering investigation, water supply, ground-water monitoring, and natural gas production. This report is a catalog of all obtainable (about 800) lithologic logs from boreholes in a portion of the Hanford Site known as the 600 Area

  7. Can individualized weight monitoring using the HeartPhone algorithm improve sensitivity for clinical deterioration of heart failure?

    LENUS (Irish Health Repository)

    Ledwidge, Mark T

    2013-04-01

    Previous studies have demonstrated poor sensitivity of guideline weight monitoring in predicting clinical deterioration of heart failure (HF). This study aimed to evaluate patterns of remotely transmitted daily weights in a high-risk HF population and also to compare guideline weight monitoring and an individualized weight monitoring algorithm.

  8. Handling and Emplacement Options for Deep Borehole Disposal Conceptual Design.

    Energy Technology Data Exchange (ETDEWEB)

    Cochran, John R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hardin, Ernest [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-07-01

    This report presents conceptual design information for a system to handle and emplace packages containing radioactive waste, in boreholes 16,400 ft deep or possibly deeper. Its intended use is for a design selection study that compares the costs and risks associated with two emplacement methods: drill-string and wireline emplacement. The deep borehole disposal (DBD) concept calls for siting a borehole (or array of boreholes) that penetrate crystalline basement rock to a depth below surface of about 16,400 ft (5 km). Waste packages would be emplaced in the lower 6,560 ft (2 km) of the borehole, with sealing of appropriate portions of the upper 9,840 ft (3 km). A deep borehole field test (DBFT) is planned to test and refine the DBD concept. The DBFT is a scientific and engineering experiment, conducted at full-scale, in-situ, without radioactive waste. Waste handling operations are conceptualized to begin with the onsite receipt of a purpose-built Type B shipping cask, that contains a waste package. Emplacement operations begin when the cask is upended over the borehole, locked to a receiving flange or collar. The scope of emplacement includes activities to lower waste packages to total depth, and to retrieve them back to the surface when necessary for any reason. This report describes three concepts for the handling and emplacement of the waste packages: 1) a concept proposed by Woodward-Clyde Consultants in 1983; 2) an updated version of the 1983 concept developed for the DBFT; and 3) a new concept in which individual waste packages would be lowered to depth using a wireline. The systems described here could be adapted to different waste forms, but for design of waste packaging, handling, and emplacement systems the reference waste forms are DOE-owned high- level waste including Cs/Sr capsules and bulk granular HLW from fuel processing. Handling and Emplacement Options for Deep Borehole Disposal Conceptual Design July 23, 2015 iv ACKNOWLEDGEMENTS This report has

  9. New experiences in borehole dilution techniques

    International Nuclear Information System (INIS)

    Umesh Chandra

    1977-01-01

    A study of filtration rate and direction of groundwater flow was made at various depths in borehole using bromine-82 as groundwater tracer. The filtration rates were found to vary along the depth of borehole. Vertical flow in the borehole was observed in an alluvial aquifer even after sealing the borehole by rubber packers. The filtration rates, obtained without the packer at various depths, were much less than those obtained with packer. Microscopic hydrological information was obtained around the borehole which was useful in planning a drainage system in the area. A depth was located in the borehole where vertical flow was in opposite directions. At another depth a zone of horizontal flow was observed where vertical flow was in opposite directions. The improved instrumentation used rendered the field work extremely easy quick and readily reproducible. (author)

  10. Criteria for calculation of effective dose from the individual monitoring; Criterios para calculo de dose efetiva a partir da monitoracao individual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-11-15

    This Regulation refers to the requirements of the Regulation CNEN-NN.3.01. 'Basic Act of Radiological Protection', as expressed in the section 5.9, and its application to the effective dose calculation for individual occupationally exposed. from the internal and external individual monitoring data

  11. A monitoring tool for performance improvement in plastic surgery at the individual level.

    Science.gov (United States)

    Maruthappu, Mahiben; Duclos, Antoine; Orgill, Dennis; Carty, Matthew J

    2013-05-01

    The assessment of performance in surgery is expanding significantly. Application of relevant frameworks to plastic surgery, however, has been limited. In this article, the authors present two robust graphic tools commonly used in other industries that may serve to monitor individual surgeon operative time while factoring in patient- and surgeon-specific elements. The authors reviewed performance data from all bilateral reduction mammaplasties performed at their institution by eight surgeons between 1995 and 2010. Operative time was used as a proxy for performance. Cumulative sum charts and exponentially weighted moving average charts were generated using a train-test analytic approach, and used to monitor surgical performance. Charts mapped crude, patient case-mix-adjusted, and case-mix and surgical-experience-adjusted performance. Operative time was found to decline from 182 minutes to 118 minutes with surgical experience (p factors is essential for correct interpretation of performance in plastic surgery at the individual surgeon level. Cumulative sum and exponentially weighted moving average charts represent accurate methods of monitoring operative time to control and potentially improve surgeon performance over the course of a career.

  12. Quality assurance in individual monitoring: A summary of the EURADOS survey 2012

    International Nuclear Information System (INIS)

    Gilvin, P.; Alves, J.G.; Cherestes, C.; Dijk, J.W.E. van; Lehtinen, M.; Rossi, F.; Vekic, B.

    2014-01-01

    EURADOS Working Group 2 (WG2) on Harmonization of Individual Monitoring is a network of individual monitoring services (IMSs) that aims to promote quality, technical excellence and good practice in European Member States. To help to improve quality, in 2012 EURADOS WG2 carried out a survey of IMSs in Europe. The survey was sent to about 170 IMS and included questions on: the use of formal quality assurance (QA) standards, QA in dosimetry, matters of practice, and common sources of error. The present paper summarises the main findings of the survey, and compares them with those of an earlier study (2003). The survey found that profile of QA is high amongst the responding IMSs, and that most are following good practice. A majority of services comply with formal quality standards and good attention is paid to traceability, method validation and proficiency testing. There are some areas where lessons can be learned, for example in the assessment of measurement uncertainty; and it remains very instructive to see what the main causes of error are for IMSs in general. - Highlights: • EURADOS has surveyed QA practice amongst European dosimetry services. • The survey was comprehensive, covering most of the monitored workers in Europe. • The profile of QA among IMS is reassuringly high. • Many services follow formal QA standards, e.g. ISO 17025. • But there are still some lessons that can be learned

  13. Individual differences in error monitoring in healthy adults: psychological symptoms and antisocial personality characteristics.

    Science.gov (United States)

    Chang, Wen-Pin; Davies, Patricia L; Gavin, William J

    2010-10-01

    Recent studies have investigated the relationship between psychological symptoms and personality traits and error monitoring measured by error-related negativity (ERN) and error positivity (Pe) event-related potential (ERP) components, yet there remains a paucity of studies examining the collective simultaneous effects of psychological symptoms and personality traits on error monitoring. This present study, therefore, examined whether measures of hyperactivity-impulsivity, depression, anxiety and antisocial personality characteristics could collectively account for significant interindividual variability of both ERN and Pe amplitudes, in 29 healthy adults with no known disorders, ages 18-30 years. The bivariate zero-order correlation analyses found that only the anxiety measure was significantly related to both ERN and Pe amplitudes. However, multiple regression analyses that included all four characteristic measures while controlling for number of segments in the ERP average revealed that both depression and antisocial personality characteristics were significant predictors for the ERN amplitudes whereas antisocial personality was the only significant predictor for the Pe amplitude. These findings suggest that psychological symptoms and personality traits are associated with individual variations in error monitoring in healthy adults, and future studies should consider these variables when comparing group difference in error monitoring between adults with and without disabilities. © 2010 The Authors. European Journal of Neuroscience © 2010 Federation of European Neuroscience Societies and Blackwell Publishing Ltd.

  14. Exploratory borehole Leuggern. Working program

    International Nuclear Information System (INIS)

    1984-07-01

    An extensive geophysical borehole logging programme will serve to verify the results of the core analysis and complement the core data. Numerous borehole logs are to be registered with different types of tools. These allow one to determine various parameters essential for the full description of the rock sequences penetrated. A first category of logs enables the petrographical identification of the different rock types and indicates porous zones that are either water- or hydrocarbon-bearing. A second category provides data e.g. on the degree of pore and fracture fill, rock density and rock temperature, natural gamma radiation and rock-mechanical properties. Other logs measure strike and dip of the sedimentary layers and the position of rock fractures. A fourth category provides information on the diameter and the deviation of the borehole, the quality of casing cementations and the position of casing joints. In addition, well shooting surveys will supply exact values of seismic velocities for the various rock units; data that are needed for the depth correction of the reflection profiles from Nagra's regional seismic network. With numerous hydrological tests ranging from a production tests of the Muschelkalk and Buntsandstein aquifers to labelled slug-tests in low-permeability crystalline sections, the hydraulic conditions of deep groundwater flow will be investigated. The recovered water samples will undergo full physical and geochemical analysis. Furthermore, their isotope content is to be measured in order to estimate the age of the various formation waters and their time of residence in the subsurface. To round off the scientific investigations, a series of rock-mechanical and geotechnical laboratory tests will provide characteristic values to be applied eventually in the design and construction of shafts and caverns for an underground repository

  15. Cement thickness measurements in cased boreholes

    International Nuclear Information System (INIS)

    Wahl, J.S.; Schuster, N.A.

    1978-01-01

    Methods and apparatus are provided for logging a borehole having solid matter along at least a portion of the wall thereof. Gamma radiation is emitted from the borehole into the surrounding media, and the amount of radiation which returns to the borehole is measured by three detectors located at different distances from the source of radiation, so as to be primarily sensitive to radiation which has respectively penetrated to three different depths in the surrounding media. The thickness of the solid matter on the borehole wall is then determined from the three gamma radiation measurements

  16. The sonic borehole logging tool

    International Nuclear Information System (INIS)

    Oelgaard, P.L.

    1990-09-01

    This report deals with the sonic borehole tool. First a review of the various elastic wave types is given and velocity values of compressional waves in various materials listed. Next follows a discussion of 3 models for the relation between transit time and porosity, and a comparison between the 3 models is made. The design of sonic tools is described including their geometry. The path of the sonic signals is discussed. Also the effect of environmental factors on the results of the tools are considered. Finally a number of applications are described. In two appendices the mechanics of deformable bodies and formulas for the velocity of sound are reviewed. (author)

  17. Comparing infants' use of featural and spatiotemporal information when individuating objects in an event monitoring design

    DEFF Research Database (Denmark)

    Krøjgaard, Peter

    . The results obtained using this design reveal that infants are more successful using spatiotemporal object information than when using featural information. However, recent studies using the less cognitively demanding event monitoring design have revealed that even younger infants are capable of object...... in the present series of experiments in which infants' use of spatiotemporal and featural information is compared directly using the less demanding event monitoring design. The results are discussed in relation to existing empirical evidence......., to what extent infants rely on spatiotemporal or featural object information when individuating objects is currently under debate. Hitherto, infants' use of spatiotemporal and featural object information has only been compared directly using the rather cognitively demanding event mapping design...

  18. Borehole Summary Report for Core Hole C4998 – Waste Treatment Plant Seismic Boreholes Project

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, D. BRENT; Garcia, Benjamin J.

    2006-12-15

    Seismic borehole C4998 was cored through the upper portion of the Columbia River Basalt Group and Ellensburg Formation to provide detailed lithologic information and intact rock samples that represent the geology at the Waste Treatment Plant. This report describes the drilling of borehole C4998 and documents the geologic data collected during the drilling of the cored portion of the borehole.

  19. Scanning an individual monitoring database for multiple occurrences using bi-gram analysis

    International Nuclear Information System (INIS)

    Van Dijk, J. W. E.

    2007-01-01

    Maintaining the integrity of the databases is one of the important aspects of quality assurance at individual monitoring services and national dose registers. This paper presents a method for finding and preventing the occurrence of duplicate entries in the databases that can occur, e.g. because of a variable spelling or misspelling of the name. The method is based on bi-gram text analysis techniques. The methods can also be used for retrieving dose data in historical databases in the framework of dose reconstruction efforts of persons of whom the spelling of the name as originally entered, possibly decades ago, is uncertain. (authors)

  20. Development of in vitro techniques for individual monitoring of "3"2P

    International Nuclear Information System (INIS)

    Almeida, A.P.F.; Sousa, W.O.; Dantas, A.L.A.; Dantas, B.M.

    2016-01-01

    The "3"2P is used in the form of liquid unsealed sources in medical facilities, research and teaching, representing a risk of internal exposure in routine activities and in case of accidental incorporation. The evaluation of "3"2P incorporation can be accomplished through in vitro bioanalysis of urine. This paper aims to provide a methodology to analyze "3"2P in biological samples, applicable to internal individual monitoring using liquid scintillation technique. The minimum detectable activity of the system was determined and the sensitivity of the technique was evaluated, based on the detected minimum effective dose. (author)

  1. Individual Radiation Protection Monitoring in the Marshall Islands. Utrok Atoll (2010-2012)

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, T. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kehl, S. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Martinelli, R. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hickman, R. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hickman, D. P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Tumey, S. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brown, T. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Langston, R. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Tamblin, M. W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Tibon, S. [Utrok Whole Body Counting Facility, Majuro Atoll (Republic of the Marshall Islands); Chee, L. [Utrok Whole Body Counting Facility, Majuro Atoll (Republic of the Marshall Islands); Aisek, Jr., A. [Utrok Whole Body Counting Facility, Majuro Atoll (Republic of the Marshall Islands); DeDrum, Z. [Utrok Whole Body Counting Facility, Majuro Atoll (Republic of the Marshall Islands); Mettao, M. [Utrok Whole Body Counting Facility, Majuro Atoll (Republic of the Marshall Islands); Henson, J. [Utrok Whole Body Counting Facility, Majuro Atoll (Republic of the Marshall Islands)

    2014-12-15

    As a hard copy supplement to the Marshall Islands Program website (https://marshallislands.llnl.gov), this document provides an overview of the individual radiological surveillance monitoring program established in support of residents of Utrōk Atoll and nonresident citizens of the Utrōk Atoll population group, along with full disclosure of verified measurement data (2010-2012). The Utrōk Atoll Whole Body Counting Facility has been temporarily stationed on Majuro Atoll and, in cooperation with the Utrōk Atoll Local Government, serves as a national radiological facility open to the general public.

  2. Individual monitoring of internal exposure to uranium oxides in two fuel fabrication plants

    International Nuclear Information System (INIS)

    Bourdeix, F.; Achiary, J.; Berard, P.

    1989-01-01

    Individual monitoring of personal exposure to inhalation of uranium oxides throughout the manufacture of fuel for pressurized water reactor (PWR) includes lung gamma-spectrometry, fecal analysis and urine analysis. Examination of the results shows the following: internal exposure is the consequence of repeated intake incidents as revealed by early peaks of urinary and particularly fecal elimination; a shift is often observed with the results of aerosol concentration measured through air collectors; the measured variations of uranium lung incorporations are relatively fast (apparent mean period 165 d). Correct evaluation of the effective dose equivalent from inhalation requires further information concerning the aerosol size distribution at work stations, the physico-chemical characteristics of the product leading to an estimate of its actual biological solubility, and the measurement of the fraction of aerosol liable to intake with an individual portable collector [fr

  3. High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Antonioli, Cleonice Aparecida Silva

    2015-12-01

    Full Text Available Introduction The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. Objective This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. Data Synthesis This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: “Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?” The search was based on PubMed data, Base, Web of Science (Capes, Biblioteca Virtual em Saúde (BVS, and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. Conclusion The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33, as well as the 4 KHz frequency (CA, this one being a little less expressive (MD = 5.72. Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace.

  4. High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review.

    Science.gov (United States)

    Antonioli, Cleonice Aparecida Silva; Momensohn-Santos, Teresa Maria; Benaglia, Tatiana Aparecida Silva

    2016-07-01

    The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: "Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?" The search was based on PubMed data, Base, Web of Science (Capes), Biblioteca Virtual em Saúde (BVS), and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA) frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33)), as well as the 4 KHz frequency (CA), this one being a little less expressive (MD = 5.72). Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace.

  5. A New Method to Individualize Monitoring of Muscle Recovery in Athletes.

    Science.gov (United States)

    Hecksteden, Anne; Pitsch, Werner; Julian, Ross; Pfeiffer, Mark; Kellmann, Michael; Ferrauti, Alexander; Meyer, Tim

    2017-10-01

    Assessment of muscle recovery is essential for the daily fine-tuning of training load in competitive sports, but individual differences may limit the diagnostic accuracy of group-based reference ranges. This article reports an attempt to develop individualized reference ranges using a Bayesian approach comparable to that developed for the Athlete Biological Passport. Urea and creatine kinase (CK) were selected as indicators of muscle recovery. For each parameter, prior distributions and repeated-measures SDs were characterized based on data of 883 squad athletes (1758 data points, 1-8 per athlete, years 2013-2015). Equations for the individualization procedure were adapted from previous material to allow for discrimination of 2 physiological states (recovered vs nonrecovered). Evaluation of classificatory performance was carried out using data from 5 consecutive weekly microcycles in 14 elite junior swimmers and triathletes. Blood samples were collected every Monday (recovered) and Friday according to the repetitive weekly training schedule over 5 wk. On the group level, changes in muscle recovery could be confirmed by significant differences in urea and CK and validated questionnaires. Group-based reference ranges were derived from that same data set to avoid overestimating the potential benefit of individualization. For CK, error rates were significantly lower with individualized classification (P vs group-based: test-pass error rate P = .008; test-fail error rate P < .001). For urea, numerical improvements in error rates failed to reach significance. Individualized reference ranges seem to be a promising tool to improve accuracy of monitoring muscle recovery. Investigating application to a larger panel of indicators is warranted.

  6. Individual internal monitoring of workers of Fabrica de Combustivel Nuclear - FCN

    International Nuclear Information System (INIS)

    Castro, Marcelo X.

    2005-01-01

    In nuclear fuel fabrication facilities, workers are exposed to different compounds of enriched uranium. Due to the high cost of the individual monitoring programme for internal dose assessment in the routine monitoring programmes, usually only one type of measurement is assigned. In complex situations like the one described in this paper, where several parameters can compromise the accuracy of the bioassay interpretation it is need to have a combination of techniques to evaluate the internal dose. According to ICRP 78 (1997), the general order of preference in terms of accuracy of interpretation is: body activity measurement, excreta analysis and personal air sampling. A group of fifteen workers from controlled area of the fuel fabrication facility was selected to evaluate the internal dose using all different available techniques during a certain period. The workers were monitored for determination of uranium content in the daily urinary excretion, faecal excretion, chest counting and personal air sampling (PAS). The results have shown that at least two types of sensitivity techniques must be used, since there are some sources of uncertainties on the bioassay interpretation, like mixture of uranium compounds intake and different routes of intake. The combination of urine and faeces analysis has shown be the more appropriate methodology for assessing internal dose in this situation. (author)

  7. Systemic Case Formulation, Individualized Process Monitoring, and State Dynamics in a Case of Dissociative Identity Disorder.

    Science.gov (United States)

    Schiepek, Günter K; Stöger-Schmidinger, Barbara; Aichhorn, Wolfgang; Schöller, Helmut; Aas, Benjamin

    2016-01-01

    Objective: The aim of this case report is to demonstrate the feasibility of a systemic procedure (synergetic process management) including modeling of the idiographic psychological system and continuous high-frequency monitoring of change dynamics in a case of dissociative identity disorder. The psychotherapy was realized in a day treatment center with a female client diagnosed with borderline personality disorder (BPD) and dissociative identity disorder. Methods: A three hour long co-creative session at the beginning of the treatment period allowed for modeling the systemic network of the client's dynamics of cognitions, emotions, and behavior. The components (variables) of this idiographic system model (ISM) were used to create items for an individualized process questionnaire for the client. The questionnaire was administered daily through an internet-based monitoring tool (Synergetic Navigation System, SNS), to capture the client's individual change process continuously throughout the therapy and after-care period. The resulting time series were reflected by therapist and client in therapeutic feedback sessions. Results: For the client it was important to see how the personality states dominating her daily life were represented by her idiographic system model and how the transitions between each state could be explained and understood by the activating and inhibiting relations between the cognitive-emotional components of that system. Continuous monitoring of her cognitions, emotions, and behavior via SNS allowed for identification of important triggers, dynamic patterns, and psychological mechanisms behind seemingly erratic state fluctuations. These insights enabled a change in management of the dynamics and an intensified trauma-focused therapy. Conclusion: By making use of the systemic case formulation technique and subsequent daily online monitoring, client and therapist continuously refer to detailed visualizations of the mental and behavioral network and

  8. Interpretation of the results from individual monitoring of workers at the Nuclear Fuel Fabrication Facility, Brazil

    International Nuclear Information System (INIS)

    Castro, Marcelo Xavier de

    2005-01-01

    In nuclear fuel fabrication facilities, workers are exposed to different compounds of enriched uranium. Although in this kind of facility the main route of intake is inhalation, ingestion may occur in some situations, and also a mixture of both. The interpretation of the bioassay data is very complex, since it is necessary taking into account all the different parameters, which is a big challenge. Due to the high cost of the individual monitoring programme for internal dose assessment in the routine monitoring programmes, usually only one type of measurement is assigned. In complex situations like the one described in this study, where several parameters can compromise the accuracy of the bioassay interpretation it is need to have a combination of techniques to evaluate the internal dose. According to ICRP 78 (1997), the general order of preference of measurement methodologies in terms of accuracy of interpretation is: body activity measurement, excreta analysis and personal air sampling. Results of monitoring of working environment may provide information that assists in the interpretation on particle size, chemical form, solubility and date of intake. A group of fifteen workers from controlled area of the studied nuclear fuel fabrication facility was selected to evaluate the internal dose using all different available techniques during a certain period. The workers were monitored for determination of uranium content in the daily urinary and faecal excretion (collected over a period of 3 consecutive days), chest counting and personal air sampling. The results have shown that at least two types of sensitivity techniques must be used, since there are some sources of uncertainties on the bioassay interpretation, like mixture of uranium compounds intake and different routes of intake. The combination of urine and faeces analysis has shown to be the more appropriate methodology for assessing internal dose in this situation. The chest counting methodology has not shown

  9. Systemic Case Formulation, Individualized Process Monitoring, and State Dynamics in a Case of Dissociative Identity Disorder.

    Directory of Open Access Journals (Sweden)

    Guenter Karl Schiepek

    2016-10-01

    Full Text Available Objective. The aim of this case report is to demonstrate the feasibility of a systemic procedure (synergetic process management including modeling of the idiographic psychological system and continuous high-frequency monitoring of change dynamics in a case of dissociative identity disorder. The psychotherapy was realized in a day treatment center with a female client diagnosed with borderline personality disorder (BPD and dissociative identity disorder. Methods. A three hour long co-creative session at the beginning of the treatment period allowed for modeling the systemic network of the client’s dynamics of cognitions, emotions, and behavior. The components (variables of this idiographic system model (ISM were used to create items for an individualized process questionnaire for the client. The questionnaire was administered daily through an internet-based monitoring tool (Synergetic Navigation System, SNS, to capture the client’s individual change process continuously throughout the therapy and after-care period. The resulting time series were reflected by therapist and client in therapeutic feedback sessions. Results. For the client it was important to see how the personality states dominating her daily life were represented by her idiographic system model and how the transitions between each state could be explained and understood by the activating and inhibiting relations between the cognitive-emotional components of that system. Continuous monitoring of her cognitions, emotions, and behavior via SNS allowed for identification of important triggers, dynamic patterns, and psychological mechanisms behind seemingly erratic state fluctuations. These insights enabled a change in management of the dynamics and an intensified trauma-focused therapy. Conclusion. By making use of the systemic case formulation technique and subsequent daily online monitoring, client and therapist continuously refer to detailed visualizations of the mental and

  10. Optimization of Deep Borehole Systems for HLW Disposal

    International Nuclear Information System (INIS)

    Driscoll, Michael; Baglietto, Emilio; Buongiorno, Jacopo; Lester, Richard; Brady, Patrick; Arnold, B. W.

    2015-01-01

    This is the final report on a project to update and improve the conceptual design of deep boreholes for high level nuclear waste disposal. The effort was concentrated on application to intact US legacy LWR fuel assemblies, but conducted in a way in which straightforward extension to other waste forms, host rock types and countries was preserved. The reference fuel design version consists of a vertical borehole drilled into granitic bedrock, with the uppermost kilometer serving as a caprock zone containing a diverse and redundant series of plugs. There follows a one to two kilometer waste canister emplacement zone having a hole diameter of approximately 40-50 cm. Individual holes are spaced 200-300 m apart to form a repository field. The choice of verticality and the use of a graphite based mud as filler between the waste canisters and the borehole wall liner was strongly influenced by the expectation that retrievability would continue to be emphasized in US and worldwide repository regulatory criteria. An advanced version was scoped out using zinc alloy cast in place to fill void space inside a disposal canister and its encapsulated fuel assembly. This excludes water and greatly improves both crush resistance and thermal conductivity. However the simpler option of using a sand fill was found adequate and is recommended for near-term use. Thermal-hydraulic modeling of the low permeability and porosity host rock and its small (@@@ 1%) saline water content showed that vertical convection induced by the waste's decay heat should not transport nuclides from the emplacement zone up to the biosphere atop the caprock. First order economic analysis indicated that borehole repositories should be cost-competitive with shallower mined repositories. It is concluded that proceeding with plans to drill a demonstration borehole to confirm expectations, and to carry out priority experiments, such as retention and replenishment of in-hole water is in order.

  11. Optimization of Deep Borehole Systems for HLW Disposal

    Energy Technology Data Exchange (ETDEWEB)

    Driscoll, Michael [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Baglietto, Emilio [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Buongiorno, Jacopo [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Lester, Richard [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Brady, Patrick [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Arnold, B. W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-09

    This is the final report on a project to update and improve the conceptual design of deep boreholes for high level nuclear waste disposal. The effort was concentrated on application to intact US legacy LWR fuel assemblies, but conducted in a way in which straightforward extension to other waste forms, host rock types and countries was preserved. The reference fuel design version consists of a vertical borehole drilled into granitic bedrock, with the uppermost kilometer serving as a caprock zone containing a diverse and redundant series of plugs. There follows a one to two kilometer waste canister emplacement zone having a hole diameter of approximately 40-50 cm. Individual holes are spaced 200-300 m apart to form a repository field. The choice of verticality and the use of a graphite based mud as filler between the waste canisters and the borehole wall liner was strongly influenced by the expectation that retrievability would continue to be emphasized in US and worldwide repository regulatory criteria. An advanced version was scoped out using zinc alloy cast in place to fill void space inside a disposal canister and its encapsulated fuel assembly. This excludes water and greatly improves both crush resistance and thermal conductivity. However the simpler option of using a sand fill was found adequate and is recommended for near-term use. Thermal-hydraulic modeling of the low permeability and porosity host rock and its small (≤ 1%) saline water content showed that vertical convection induced by the waste’s decay heat should not transport nuclides from the emplacement zone up to the biosphere atop the caprock. First order economic analysis indicated that borehole repositories should be cost-competitive with shallower mined repositories. It is concluded that proceeding with plans to drill a demonstration borehole to confirm expectations, and to carry out priority experiments, such as retention and replenishment of in-hole water is in order.

  12. 30 CFR 75.1318 - Loading boreholes.

    Science.gov (United States)

    2010-07-01

    ... protect persons shall be done in the working place or other area where blasting is to be performed. (c) When loading boreholes drilled at an angle of 45 degrees or greater from the horizontal in solid rock... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Explosives and Blasting § 75.1318 Loading boreholes. (a...

  13. 30 CFR 75.1322 - Stemming boreholes

    Science.gov (United States)

    2010-07-01

    ... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Explosives and Blasting § 75.1322 Stemming boreholes (a... deep shall be stemmed for at least half the depth of the borehole. (f) When blasting off the solid in... water stemming bag shall be within 1/4 of an inch of the diameter of the drill bit used to drill the...

  14. Borehole imaging tool detects well bore fractures

    International Nuclear Information System (INIS)

    Ma, T.A.; Bigelow, E.L.

    1993-01-01

    This paper reports on borehole imaging data which can provide high quality geological and petrophysical information to improve fracture identification, dip computations, and lithology determinations in a well bore. The ability to visually quantify the area of a borehole wall occupied by fractures and vugs enhances reservoir characterization and well completion operations. The circumferential borehole imaging log (CBIL) instrument is an acoustic logging device designed to produce a map of the entire borehole wall. The visual images can confirm computed dips and the geological features related to dip. Borehole geometry, including breakout, are accurately described by complete circumferential caliper measurements, which is important information for drilling and completion engineers. In may reservoirs, the images can identify porosity type, bedding characteristics, and petrophysical parameters

  15. A borehole stability study by newly designed laboratory tests on thick-walled hollow cylinders

    Directory of Open Access Journals (Sweden)

    S.S. Hashemi

    2015-10-01

    Full Text Available At several mineral exploration drilling sites in Australia, weakly consolidated formations mainly consist of sand particles that are poorly bonded by cementing agents such as clay, iron oxide cement or calcite. These formations are being encountered when drilling boreholes to the depth of up to 200 m. To study the behaviour of these materials, thick-walled hollow cylinder (TWHC and solid cylindrical synthetic specimens were designed and prepared by adding Portland cement and water to sand grains. The effects of different parameters such as water and cement contents, grain size distribution and mixture curing time on the characteristics of the samples were studied to identify the mixture closely resembling the formation at the drilling site. The Hoek triaxial cell was modified to allow the visual monitoring of grain debonding and borehole breakout processes during the laboratory tests. The results showed the significance of real-time visual monitoring in determining the initiation of the borehole breakout. The size-scale effect study on TWHC specimens revealed that with the increasing borehole size, the ductility of the specimen decreases, however, the axial and lateral stiffnesses of the TWHC specimen remain unchanged. Under different confining pressures the lateral strain at the initiation point of borehole breakout is considerably lower in a larger size borehole (20 mm compared to that in a smaller one (10 mm. Also, it was observed that the level of peak strength increment in TWHC specimens decreases with the increasing confining pressure.

  16. Evaluation of performance of electronic dosimeters for individual monitoring: tests in laboratory; Avaliacao do desempenho de dosimetros eletronicos para monitoracao individual: testes em laboratorio

    Energy Technology Data Exchange (ETDEWEB)

    Garzon, W.J.; Khoury, H.J.; Barros, V.S.M. de, E-mail: wjaramig@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife (Brazil). Departamento de Energia Nuclear. Laboratorio de Metrologia das Radiacoes Ionizantes; Medeiros, R.B. [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Departamento de Diagnostico por Imagem

    2015-07-01

    Electronic dosimeters based on direct ion storage technology are being widely used in many countries for individual monitoring in many applications of ionizing radiation. However, their use as routine dosimeter has been established in a few countries due to lack of accreditation or intercomparison programs. The objective of this study is to evaluate the performance of two direct íon storage dosimeters model available in the international market: the Miriom-Instadose-1 and RADOS DIS-1 to be eventually accepted for individual monitoring in Brazil. (author)

  17. Surface and Subsurface Geodesy Combined with Active Borehole Experimentation for the Advanced Characterization of EGS Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Elsworth, Derek [Pennsylvania State Univ., University Park, PA (United States); Im, Kyungjae [Pennsylvania State Univ., University Park, PA (United States); Guglielmi, Yves [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mattioli, Glen [Univ. of Texas, Arlington, TX (United States). UNAVCO

    2016-11-14

    We explore the utility of combining active downhole experimentation with borehole and surface geodesy to determine both the characteristics and evolving state of EGS reservoirs during stimulation through production. The study is divided into two parts. We demonstrate the feasibility of determining in situ reservoir characteristics of reservoir size, strain and fracture permeability and their dependence on feedbacks of stress and temperature using surface and borehole geodetic measurements (Part I). We then define the opportunity to apply the unique hydraulic pulse protocol (HPP) borehole tool to evaluate reservoir state. This can be accomplished by monitoring and co-inverting measured reservoir characteristics (from the HPP tool) with surface geodetic measurements of deformation, tilt and strain with continuous measurements of borehole-wall strain (via optical fiber and fiber Bragg gratings) and measured flow rates (Part II).

  18. Deep borehole disposal of plutonium

    International Nuclear Information System (INIS)

    Gibb, F. G. F.; Taylor, K. J.; Burakov, B. E.

    2008-01-01

    Excess plutonium not destined for burning as MOX or in Generation IV reactors is both a long-term waste management problem and a security threat. Immobilisation in mineral and ceramic-based waste forms for interim safe storage and eventual disposal is a widely proposed first step. The safest and most secure form of geological disposal for Pu yet suggested is in very deep boreholes and we propose here that the key to successful combination of these immobilisation and disposal concepts is the encapsulation of the waste form in small cylinders of recrystallized granite. The underlying science is discussed and the results of high pressure and temperature experiments on zircon, depleted UO 2 and Ce-doped cubic zirconia enclosed in granitic melts are presented. The outcomes of these experiments demonstrate the viability of the proposed solution and that Pu could be successfully isolated from its environment for many millions of years. (authors)

  19. Deep Borehole Disposal Safety Analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Freeze, Geoffrey A. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Stein, Emily [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Price, Laura L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); MacKinnon, Robert J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Tillman, Jack Bruce [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    This report presents a preliminary safety analysis for the deep borehole disposal (DBD) concept, using a safety case framework. A safety case is an integrated collection of qualitative and quantitative arguments, evidence, and analyses that substantiate the safety, and the level of confidence in the safety, of a geologic repository. This safety case framework for DBD follows the outline of the elements of a safety case, and identifies the types of information that will be required to satisfy these elements. At this very preliminary phase of development, the DBD safety case focuses on the generic feasibility of the DBD concept. It is based on potential system designs, waste forms, engineering, and geologic conditions; however, no specific site or regulatory framework exists. It will progress to a site-specific safety case as the DBD concept advances into a site-specific phase, progressing through consent-based site selection and site investigation and characterization.

  20. Field monitoring versus individual miner dosimetry of radon daughter products in mines.

    Science.gov (United States)

    Domański, T; Kluszczyński, D; Olszewski, J; Chruscielewski, W

    1989-01-01

    The paper presents the results realised simultaneously by two different and independent systems of measurement of an assessment of miners' exposure to radon daughter products which naturally occur in the air of mines. The first one, called the Air Sampling System (ASS), was based on the field monitoring of radon progeny in air, the second one, called the Individual Dosimetry System (IDS), was based on the individual dosimeters worn by miners. Experimental comparison of these two systems has been conducted for six years in eleven Polish underground metal-ore mines. This study reveals that no correlation exists between the concentration and annual miners' exposures evaluated by the ASS and IDS. The ratio ASS/IDS for mine population varies from 11.0 to 0.14 in respect of annual concentration means, and in respect to annual exposures, this ratio varies from 4.5 to 0.14. The conclusion to be drawn from six years' observation and comparison of both systems is that correct and true evaluation of miners' exposure to radon progeny can be made only by the use of the Individual Dosimetry System, since the Air Sampling System is too sensitive and too dependent on the Strategy of sampling and its radiation.

  1. The role of the National Metrology laboratory for the improvement for the improvement of the individual monitoring in brazil

    International Nuclear Information System (INIS)

    Barbosa, R.A.; Baptista, L.A.M.M.; Silva, T.A. da

    1998-01-01

    Since 1980, the National Laboratory for ionising Radiation Metrology- LNMRI/IRD from Brazil has given support and performed quality control tests in the services that provide individual monitoring of external radiation in the country. Although the LNMRI/IRD has promoted intercomparisons and performance tests in all Brazilian individual monitoring systems, results showed that improvements in the their quality were too small, mainly due to a lack of a national policy and legal requirements for quality control them. In 1996, the Committee for Evaluation of External Individual Monitoring Services established a national policy for accreditation of individual monitoring services. In the new policy, the role of the LNMRI/IRD is mainly to verify the compliance of any individual monitoring system to the minimum accuracy requirements for the photon dose equivalent evaluation. Additionally, the LNMRI/IRD may verify any specific type-test to verify the results stated by the service itself. A new quality control program for all accredited services is also to be maintained by the LNMRI/IRD . This work shows and discusses the results of the role of the LNMRI/IRD under the old and the new accreditation policy for the systems used for the individual monitoring of photon beams

  2. POSSIBILITIES OF TEACHERS FOR MONITORING, DETECTING AND RECORDING OF INDIVIDUAL CHARACTERISTICS OF STUDENTS IN EARLY SCHOOL AGE

    Directory of Open Access Journals (Sweden)

    Tatjana Koteva-mojsovska

    2015-06-01

    Full Text Available The monitoring and recording of the individual characteristics of children are very important for the development of quality education. Also the views of the teachers about the differences in the development, the potentials and the affinities of the children in the early school period are especially important. The quality education process in the modern school should be adapted to the individual potentials of the children. The children are individuals with their own integrity and characteristics. (Johnston and Halocha, 2010. They have individual pace and develop individual approaches in the learning process. This individual pace in the development of the children requires the teachers to regularly monitor and record the individual characteristics and differences of the children, monitoring the children’s interests, planning instruction which will adapt to the different learning approaches and the different pace of progress of the students.Setting out from this paradigm, this paper, which is based on a realized research, aims to offer findings about the treatment of the individual characteristics of the early school-age children in our country. According to this, we carried out a research in four primary schools in Skopje, which showed us that the teachers lack the appropriate conditions and possibilities to monitor and record the individual characteristics and the specific differences of the students in the early school period. 

  3. Routine individual monitoring of aircrew: Czech experience and results since 1998

    International Nuclear Information System (INIS)

    Spurny, F.; Ploc, O.

    2005-01-01

    Full text: International Commission on Radiological Protection (ICRP) recommended in its Publication 60 that the radiation exposure due to the cosmic component at high altitudes be taken into account when appropriate as part of occupational exposure to the radiation. Air crew members have become in such a way another group of workers for whom the exposure to ionizing radiation is one of important occupational hazard. The recommendation mentioned was incorporated to the Czech regulation already at 1997, the studies how to perform individual dosimetry of Czech companies aircrew has started immediately after. The contribution describes first the preliminary studies with the goal to elaborate optimal procedure for the aircrew routine individual dosimetry. It was decided to perform individual monitoring through the calculation based on the information on the flights realized during a period and the list of aircrew members participated in them. As a transport code CARI was chosen, since the beginning the version 6 has been used. The information on the flight schedules and the participation of aircrew in is received from the air company. In the Czech Republic, three companies are concerned with. The procedure was proposed to the Czech authorities and it received their accreditation. Routine individual dosimetry has started since 1998. It is regularly checked and innovated. Main results for the period 1998 - 2003 are as follows: both relative frequencies as well as average annual effective dosis vary with the company and with the year, without any evident general tendency; the average values of E are between 1.5 and 2 mSv, closely to the higher value; this average value is slightly higher for charter type air-companies. Further more detailed analysis will be presented, as well as future possible modifications of the procedure. (author)

  4. Prescription Monitoring Program Trends Among Individuals Arrested in Maine for Trafficking Prescription Drugs in 2014.

    Science.gov (United States)

    McCall, Kenneth; Nichols, Stephanie D; Holt, Christina; Ochs, Leslie; Cattabriga, Gary; Tu, Chunhao

    2016-06-01

    To evaluate controlled substance prescribing trends available in the Maine Prescription Monitoring Program (PMP) among individuals arrested for prescription drug "trafficking." The demographic characteristics of the individuals who had matching prescription records in the PMP within 90 days of the arrest were identified. A population-based, retrospective cohort study using data from the Maine Diversion Alert Program (DAP) and the Maine PMP. The study population consisted of persons arrested for trafficking prescription drugs in Maine during the 2014 calendar year from January 1 to December 31. There were 594 trafficking arrests reported by the Maine DAP in 2014. The study population consisted of the 235 persons (40%) with arrests involving controlled prescription medications. The mean age of these persons was 33 years (range 18-77 yrs), and 156 (66%) were male. Arrests involved 154 prescription opioids (65%), seven stimulants (3%), seven benzodiazepines (3%), and 77 unspecified controlled prescription drugs (33%). A minority of individuals (n=57, 24%) had a prescription record in the PMP that matched the substance involved in the arrest. Only one person with matching PMP and arrest records utilized ≥ 5 prescribers, while none used ≥ 5 pharmacies within 90 days before the arrest. Payment methods for matching prescriptions were commercial insurance (n=28, 49%), Medicaid (n=19, 33%), Medicare (n=5, 9%), and cash (n=5, 9%). The majority (76%) of persons arrested for prescription drug trafficking did not have PMP records and did not directly obtain the diverted medication from a licensed pharmacy. Traditional red flags, like cash payment and using multiple prescribers or pharmacies, were uncommon. Therefore, arrest records for diversion and PMPs are distinct and complementary tools for identifying individuals at risk for substance misuse. © 2016 Pharmacotherapy Publications, Inc.

  5. Eurados self-sustained programme of intercomparisons for individual monitoring services

    International Nuclear Information System (INIS)

    Grimbergen, T. W. M.; Figel, M.; Romero, A. M.; Stadtmann, H.; McWhan, A. F.

    2011-01-01

    Within EURADOS working group 2, a system for self-sustained intercomparisons for individual monitoring services for external radiation was developed. With the intercomparison results, the participants can show compliance within their quality management system, compare their results with those from other participants and develop plans for improvement of their system. The costs of the exercises are covered by the participants fees. In this programme, the first intercomparison exercise for whole-body dosemeters has been executed in 2008 with 62 participating dosimetry systems from participants across Europe. In general, film systems show the largest deviations, although the results of some participants indicate that it is possible to achieve results with a film system with similar quality as for thermoluminescence dosimetry (TLD) systems. A second intercomparison has been organised for extremity dosemeters in 2009. For 2010 it is planned to organise a second intercomparison for whole-body dosemeters. (authors)

  6. Sources of uncertainty in individual monitoring for photographic,TL and OSL dosimetry techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Max S.; Silva, Everton R.; Mauricio, Claudia L.P., E-mail: max.das.ferreira@gmail.com, E-mail: everton@ird.gov.br, E-mail: claudia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The identification of the uncertainty sources and their quantification is essential to the quality of any dosimetric results. If uncertainties are not stated for all dose measurements informed in the monthly dose report to the monitored radiation facilities, they need to be known. This study aims to analyze the influence of different sources of uncertainties associated with photographic, TL and OSL dosimetric techniques, considering the evaluation of occupational doses of whole-body exposure for photons. To identify the sources of uncertainty it was conducted a bibliographic review in specific documents that deal with operational aspects of each technique and the uncertainties associated to each of them. Withal, technical visits to individual monitoring services were conducted to assist in this identification. The sources of uncertainty were categorized and their contributions were expressed in a qualitative way. The process of calibration and traceability are the most important sources of uncertainties, regardless the technique used. For photographic dosimetry, the remaining important uncertainty sources are due to: energy and angular dependence; linearity of response; variations in the films processing. For TL and OSL, the key process for a good performance is respectively the reproducibility of the thermal and optical cycles. For the three techniques, all procedures of the measurement process must be standardized, controlled and reproducible. Further studies can be performed to quantify the contribution of the sources of uncertainty. (author)

  7. Effects of the deviation characteristics of nuclear waste emplacement boreholes on borehole liner stresses

    International Nuclear Information System (INIS)

    Glowka, D.A.

    1990-09-01

    This report investigates the effects of borehole deviation on the useability of lined boreholes for the disposal of high-level nuclear waste at the proposed Yucca Mountain Repository in Nevada. Items that lead to constraints on borehole deviation include excessive stresses that could cause liner failure and possible binding of a waste container inside the liner during waste emplacement and retrieval operations. Liner stress models are developed for two general borehole configurations, one for boreholes drilled with a steerable bit and one for boreholes drilled with a non-steerable bit. Procedures are developed for calculating liner stresses that arise both during insertion of the liner into a borehole and during the thermal expansion process that follows waste emplacement. The effects of borehole curvature on the ability of the waste container to pass freely inside the liner without binding are also examined. Based on the results, specifications on borehole deviation allowances are developed for specific vertical and horizontal borehole configurations of current interest. 11 refs., 22 figs., 4 tabs

  8. Program of individual monitoring of the internal contamination and their implementation in the Republic the Cuba

    International Nuclear Information System (INIS)

    Lopez Bejerano, Gladys M.; Capote Ferrera, Eduardo; Fernandez Gomez, Isis M.; Acosta Rodriguez, Nancy; Carrazana Gonzalez, Jorge A.; Cruz Suarez, Rodolfo

    2008-01-01

    Full text: In different Cuban institutions linked fundamentally to the medical practice of nuclear medicine and the investigations, it is worked with sources open of ionizing radiations, that which makes indispensable the existence of a system of radiological surveillance that includes the control radiological individual of the received doses as a result of the occupational, such exhibition that is guaranteed that the exhibition of the Hard-working Exposed Occupationally, stay inside the recommended limits, in the International Basic Norms of Protection against the Ionizing radiations and safe-deposit of the Sources of Radiation (NBIS) and in turn adopted in the Norma Cuban. From the year 1986 in the Center of Protection and Hygiene of the Radiations is carried out in way centralized this control; but with the inconvenience of not being able to carry out the same one to workers from the domestic interior when not being feasible the transfer of these toward its headquarters, reason why the doses were ignored received in an important number of these. In and of itself the Laboratory of Internal Contamination of this institution in these years has developed managed works to define firstly, for each institution, the program of monitoring of the internal contamination of its workers using for it the methodology recommended by the OIEA where the potential doses are evaluated that for incorporation these they receive and whose results suggested the introduction of a program of individual monitoring as behavior to continue in most of the institutions. In correspondence with it was designed and established a program that included the study of feasibility of the existent equipment in the institutions to carry out the monitoring of the internal contamination using technical of measuring in vivo and in vitro, as it corresponds, their calibration, the establishment of procedures that respond to the requirements of a System of Quality for the Norma ISO/IEC 17025 and

  9. Geophysical borehole logging test procedure: Final draft

    International Nuclear Information System (INIS)

    1986-09-01

    The purpose of geophysical borehole logging from the At-Depth Facility (ADF) is to provide information which will assist in characterizing the site geologic conditions and in classifying the engineering characteristics of the rock mass in the vicinity of the ADF. The direct goals of borehole logging include identification of lithologic units and their correlation from hole to hole, identification of fractured or otherwise porous or permeable zones, quantitative or semi-quantitative estimation of various formation properties, and evaluation of factors such as the borehole diameter and orientation. 11 figs., 4 tabs

  10. Electrical resistance tomography using steel cased boreholes as long electrodes

    International Nuclear Information System (INIS)

    Daily, W; Newmark, R L; Ramirez, A

    1999-01-01

    Electrical resistance tomography (ERT) using multiple electrodes installed in boreholes has been shown to be useful for both site characterization and process monitoring. In some cases, however, installing multiple downhole electrodes is too costly (e.g., deep targets) or risky (e.g., contaminated sites). For these cases we have examined the possibility of using the steel casings of existing boreholes as electrodes. Several possibilities can be considered. The first case we investigated uses an array of steel casings as electrodes. This results in very few data and thus requires additional constraints to limit the domain of possible inverse solutions. Simulations indicate that the spatial resolution and sensitivity are understandably low but it is possible to coarsely map the lateral extent of subsurface processes such as steam floods. The second case uses an array of traditional point borehole electrodes combined with long-conductor electrodes (steel casings). Although this arrangement provides more data, in many cases it results in poor reconstructions of test targets. Results indicate that this method may hold promise for low resolution imaging where steel casings can be used as electrodes but the merits depend strongly on details of each application. Field tests using these configurations are currently being conducted

  11. Individual external monitoring system for gamma and X ray evaluation of the individual dose equivalent 'HP(10)', utilizing a photographic dosimetry technique

    International Nuclear Information System (INIS)

    Santoro, Christiana; Filho, Joao Antonio

    2008-01-01

    Full text: Individual monitoring evaluates external sources of ionizing radiation X, γ, β and n, to which workers are occupationally exposed, for ensuring safe and acceptable radiological conditions in their places of employment. The dose received by workers should attend the limits authorized by national regulatory organs. Nowadays, there are two radiometric unit systems, based on resolutions of the National Nuclear Energy Commission (NNEC) and the International Commission on Radiation Units and Measurements (ICRU); in the conventional (NNEC) system, the doses received by workers are evaluated through the individual dose H x , where dosemeters used on surface of thorax are calibrated in terms of air kerma; in the recent system (ICRU), the doses are evaluated through the individual dose equivalent H P (d), where dosemeters are calibrated in terms of dose from phantom. The recent system improves the method of evaluation, by taking into account the scattering effect and absorption of radiation in the human body. This work adapts a photographic dosimetry service to the recent ICRU publications, for evaluation of individual monitoring, in function of the individual dose equivalent H P (10) of strong penetrating radiation. For this, a methodology based on linear programming and determination of calibration curves is used for radiation capacities, wide (W) and narrow (N) spectra, as described by the International Organization for Standardization (ISO 4037-1, 1995). These calibration curves offer better accuracy in the determination of doses and energy, which will improve the quality of the service given to society. The results show that the values of individual dose equivalent, evaluated at intervals of 0.2 to 200 mSv, have lower significant uncertainties (10%) than those recommended by the ICRP 75, for individual monitoring; therefore, the evaluation system for developed doses attends the new recommendations proposed by International Commissions. From what has been

  12. Long-term, on-site borehole monitoring of gases released from an “active” fault system at 3.6km depth, TauTona Gold Mine, South Africa

    Science.gov (United States)

    Lippmann-Pipke, J.; Erzinger, J.; Zimmer, M.; Kujawa, C.; Boettcher, M. S.; Moller, H.; van Heerden, E.; Bester, A.; Reches, Z.

    2009-12-01

    Fluid transport and seismicity are interrelated. Fluids can trigger earthquakes and seismic activity can release fluids from rock formations. The study of this relationship requires direct and near-field observations at focal depth. The international DAFSAM-NELSAM*-projects focus on building the earthquake laboratory in deep gold mines in South Africa. Our DAFGAS-project (Drilling Active Faults - Gas Analytical System) aims to quantify the gases released during seismic events. One motivation for the project is to investigate the hypothesis that released fluids might be a nutrient supply for microbial ecosystems in active fault zones. Extensive underground activities started in 2004 with establishing a 25m2 cubby within the Pretorius fault zone at 3.6 km depth for the save installation of comprehensive technical equipment. For DAFGAS, subsequently two different gas analytical units were installed to measure gases collected in a 40 m long borehole crossing the fault. The DAFGAS Team and our collaborators overcame numerous technical problems. Since 2007 a dedicated air-conditioned box protects a mass spectrometer, pumps, a PC, a radon detector and electronics from the harsh underground environment. Since 2009 gas sensitive sensors and a data logger replace the spectrometer and the PC. In parallel the NELSAM project has installed 9 seismometers in a narrow network surrounding the gas collection system. The accelerometers and geophones record mining activities (e.g. drilling and ore-production blasts) as well as tens of mining-induced earthquakes (magnitude ≥ -4) on and around the Pretorius Fault each day. Data from three years is presented: Borehole temperature at 40m increased by about 0.8 °C/year to 52.3 °C; different scales of pressure variations on surface (869±5) mbar (three-week mean, maximal and minimal daily mean) and below surface (1130±15) mbar are explained by the barometric formula. The major gas concentrations are constant and air-like with 78 % N2

  13. Crosshole investigations - results from borehole radar investigations

    International Nuclear Information System (INIS)

    Olsson, O.; Falk, L.; Sandberg, E.; Forslund, O.; Lundmark, L.

    1987-05-01

    A new borehole radar system has been designed, built and tested. The system consists of borehole transmitter and receiver probes, a signal control unit for communication with the borehole probes, and a computer unit for storage and display of data. The system can be used both in singlehole and crosshole modes and probing ranges of 115 m and 300 m, respectively, have been obtained at Stripa. The borehole radar is a short pulse system which uses center frequencies in the range 20 to 60 MHz. Single hole reflection measurements have been used to identify fracture zones and to determine their position and orientation. The travel time and amplitude of the first arrival measured in a crosshole experiment can be used as input data in a tomographic analysis. (orig./DG)

  14. Dimensioning of Boreholes for Geothermal Heat Pumps

    Directory of Open Access Journals (Sweden)

    Ryška Jiøí

    2004-09-01

    Full Text Available The paper deals with determination of borehole depths for geothermal heat pumps. Basic formulae are stated for heat convection in rocks. Software EED 2.0 was used for calculation of borehole depth depending on different entering parameters. The crucial parameter is thermal conductivity of rocks. The thermal conductivity could be very variable for the same kind of rock. Therefore its in-situ determination by means of formation thermal conductivity testing is briefly described.

  15. Using boreholes as windows into groundwater ecosystems.

    Directory of Open Access Journals (Sweden)

    James P R Sorensen

    Full Text Available Groundwater ecosystems remain poorly understood yet may provide ecosystem services, make a unique contribution to biodiversity and contain useful bio-indicators of water quality. Little is known about ecosystem variability, the distribution of invertebrates within aquifers, or how representative boreholes are of aquifers. We addressed these issues using borehole imaging and single borehole dilution tests to identify three potential aquifer habitats (fractures, fissures or conduits intercepted by two Chalk boreholes at different depths beneath the surface (34 to 98 m. These habitats were characterised by sampling the invertebrates, microbiology and hydrochemistry using a packer system to isolate them. Samples were taken with progressively increasing pumped volume to assess differences between borehole and aquifer communities. The study provides a new conceptual framework to infer the origin of water, invertebrates and microbes sampled from boreholes. It demonstrates that pumping 5 m(3 at 0.4-1.8 l/sec was sufficient to entrain invertebrates from five to tens of metres into the aquifer during these packer tests. Invertebrates and bacteria were more abundant in the boreholes than in the aquifer, with associated water chemistry variations indicating that boreholes act as sites of enhanced biogeochemical cycling. There was some variability in invertebrate abundance and bacterial community structure between habitats, indicating ecological heterogeneity within the aquifer. However, invertebrates were captured in all aquifer samples, and bacterial abundance, major ion chemistry and dissolved oxygen remained similar. Therefore the study demonstrates that in the Chalk, ecosystems comprising bacteria and invertebrates extend from around the water table to 70 m below it. Hydrogeological techniques provide excellent scope for tackling outstanding questions in groundwater ecology, provided an appropriate conceptual hydrogeological understanding is applied.

  16. Geophysical logging of the Harwell boreholes

    International Nuclear Information System (INIS)

    Brightman, M.A.

    1983-08-01

    A comprehensive geophysical borehole logging survey was carried out on each of three deep boreholes drilled at the Harwell research site. KOALA and PETRA computer programs were used to analyse and interpret the logs to obtain continuous quantitative estimates of the geological and hydrogeological properties of the sequences penetrated at the Harwell site. Quantitative estimates of the mineral composition and porosity of the cores samples were made. (UK)

  17. Borehole disposal design concept in Madagascar

    International Nuclear Information System (INIS)

    Randriamarolahy, J.N.; Randriantseheno, H.F.; Andriambololona, Raoelina

    2008-01-01

    Full text: In Madagascar, sealed radioactive sources are used in several socio-economic sectors such as medicine, industry, research and agriculture. At the end of their useful lives, these radioactive sources become ionizing radiations waste and can be still dangerous because they can cause harmful effects to the public and the environment. 'Borehole disposal design concept' is needed for sitting up a safe site for storage of radioactive waste, in particular, sealed radioactive sources. Borehole disposal is an option for long-term management of small quantities of radioactive waste in compliance with the internationally accepted principles for radioactive waste management. Several technical aspects must be respected to carry out such a site like the geological, geomorphologic, hydrogeology, geochemical, meteorological and demographic conditions. Two sites are most acceptable in Madagascar such as Ankazobe and Fanjakana. A Borehole will be drilled and constructed using standard techniques developed for water abstraction, oil exploration. At the Borehole, the sealed radioactive sources are encapsulated. The capsule is inserted in a container. This type of storage is benefit for the developing countries because it is technologically simple and economic. The construction cost depends on the volume of waste to store and the Borehole depth. The borehole disposal concept provides a good level of safety to avoid human intrusion. The future protection of the generations against the propagation of the ionizing radiations is then assured. (author)

  18. Experiments on stress dependent borehole acoustic waves.

    Science.gov (United States)

    Hsu, Chaur-Jian; Kane, Michael R; Winkler, Kenneth; Wang, Canyun; Johnson, David Linton

    2011-10-01

    In the laboratory setup, a borehole traverses a dry sandstone formation, which is subjected to a controlled uniaxial stress in the direction perpendicular to the borehole axis. Measurements are made in a single loading-unloading stress cycle from zero to 10 MPa and then back down to zero stress. The applied stress and the presence of the borehole induce anisotropy in the bulk of the material and stress concentration around the borehole, both azimuthally and radially. Acoustic waves are generated and detected in the water-filled borehole, including compressional and shear headwaves, as well as modes of monopole, dipole, quadrupole, and higher order azimuthal symmetries. The linear and non-linear elastic parameters of the formation material are independently quantified, and utilized in conjunction with elastic theories to predict the characteristics of various borehole waves at zero and finite stress conditions. For example, an analytic theory is developed which is successfully used to estimate the changes of monopole tube mode at low frequency resulted from uniaxial stress, utilizing the measured material third order elasticity parameters. Comparisons between various measurements as well as that between experiments and theories are also presented. © 2011 Acoustical Society of America

  19. Borehole stability in densely welded tuffs

    International Nuclear Information System (INIS)

    Fuenkajorn, K.; Daemen, J.J.K.

    1992-07-01

    The stability of boreholes, or more generally of underground openings (i.e. including shafts, ramps, drifts, tunnels, etc.) at locations where seals or plugs are to be placed is an important consideration in seal design for a repository (Juhlin and Sandstedt, 1989). Borehole instability or borehole breakouts induced by stress redistribution could negate the effectiveness of seals or plugs. Breakout fractures along the wall of repository excavations or exploratory holes could provide a preferential flowpath for groundwater or gaseous radionuclides to bypass the plugs. After plug installation, swelling pressures exerted by a plug could induce radial cracks or could open or widen preexisting cracks in the rock at the bottom of the breakouts where the tangential compressive stresses have been released by the breakout process. The purpose of the work reported here is to determine experimentally the stability of a circular hole in a welded tuff sample subjected to various external boundary loads. Triaxial and biaxial borehole stability tests have been performed on densely welded Apache Leap tuff samples and Topopah Spring tuff samples. The nominal diameter of the test hole is 13.3 or 14.4 mm for triaxial testing, and 25.4 mm for biaxial testing. The borehole axis is parallel to one of the principal stress axes. The boreholes are drilled through the samples prior to applying external boundary loads. The boundary loads are progressively increased until breakouts occur or until the maximum load capacity of the loading system has been reached. 74 refs

  20. Borehole project - Final report of phase 3

    International Nuclear Information System (INIS)

    Pusch, R.; Ramqvist, G.

    2008-03-01

    The report describes borehole plugging techniques for use in deep boreholes extending from the ground surface, and construction and placement of plugs in holes of different lengths and orientations bored from the repository rooms. The principle employed is the one proposed in earlier phases of the project, i.e. to tightly seal those parts of boreholes where the rock has few fractures and a low hydraulic conductivity, and filling of those parts that intersect water-bearing fracture zones with physically stable material that does not need to be low-permeable. Four methods for tight plugging have been identified and tested and a technique has been found for filling boreholes that are intersected by fracture zones. The upper end of boreholes extending from the ground surface needs a 'mechanical' seal for which copper metal and concrete work well. The experience from plugging of a 550 m deep borehole at Olkiluoto (OL-KR24) has been compiled and plans worked out for sampling and testing of contacting clay and concrete in this hole and in short holes in the Aespoe URL. (orig.)

  1. Comparing plume characteristics inferred from cross-borehole geophysical data

    DEFF Research Database (Denmark)

    Haarder, Eline Bojsen; Binley, Andrew; Zibar, Majken Caroline Looms

    2012-01-01

    significantly influences results of the moment analysis. We compare results of three cross-borehole geophysical approaches for imaging tracer migration arising from a point injection of water in the unsaturated zone: three-dimensional electrical resistivity tomography (ERT), two-dimensional ground......-penetrating radar (GPR) tomography and quasi-three-dimensional GPR tomography. In the studied field experiment, a tracer was injected for a period of 5 d and was monitored both during injection and for 5 d during the subsequent redistribution. The three methods show similar characteristics of the plume development...

  2. Individual monitoring conducted by the Health Protection Agency in the London polonium-210 incident

    International Nuclear Information System (INIS)

    Bailey, Michael; Birchall, Alan; Etherington, George; Wilkins, Bernard; Bishop, Louise; Fraser, Graham; Gross, Roger; Maguire, Helen; Evans, Barry; Shaw, Karen

    2008-01-01

    Mr. Alexander Litvinenko died on 23 November 2006, having allegedly been poisoned with polonium- 210 ( 210 Po) a few weeks earlier. The police investigation identified a number of contaminated locations, including parts of several hotels, restaurants, offices and transport. An extensive programme of individual monitoring of potentially exposed persons was rapidly initiated, based on urine sampling. Methods used for low-level measurement of 210 Po in environmental samples were adapted. The Health Protection Agency set a Reporting Level of 30 mBq d -1 , results above which indicated likely intake of 210 Po from the incident. At each location, risk assessments were undertaken to identify persons with significant risk of contamination with 210 Po. These individuals were invited to provide samples, not only to enable a direct assessment to be made of their own exposures, but also to inform decisions on whether others connected with the location should provide samples, or whether they could be reassured. Urine samples from 753 people were processed: about 500 during the first month. Of these, 139 measurements were above the Reporting Level, assessed doses for 36 were in the range ≥ 1 mSv and <6 mSv, and 17 were ≥ 6 mSv, with the highest at about 100 mSv. Many of the hotel guests were overseas visitors. An Overseas Advice Team was set up to encourage authorities abroad to adopt similar strategies. Overall, 664 persons from 52 countries and territories were identified. For 176, results of urine measurements were provided to the Overseas Advice Team, of which 13 were above the Reporting Level. Assessed doses for eight of these were <1 mSv, and the other five were in the range ≥ 1 mSv and <6 mSv. (author)

  3. Conflict monitoring and adaptation in individuals at familial risk for developing bipolar disorder.

    Science.gov (United States)

    Patino, Luis R; Adler, Caleb M; Mills, Neil P; Strakowski, Stephen M; Fleck, David E; Welge, Jeffrey A; DelBello, Melissa P

    2013-05-01

    To examine conflict monitoring and conflict-driven adaptation in individuals at familial risk for developing bipolar disorder. We recruited 24 adolescents who had a parent with bipolar disorder and 23 adolescents with healthy parents. Participants completed an arrow version of the Eriksen Flanker Task that included trials with three levels of conflict: neutral, congruent, and incongruent flanks. Differences in performance were explored based upon the level of conflict in the current and previous trials. Individuals at risk for developing bipolar disorder performed more slowly than youth with healthy parents in all trials. Analyses evaluating sequential effects revealed that at-risk subjects responded more slowly than youth of healthy parents for all trial types when preceded by an incongruent trial, for incongruent trials preceded by congruent trials, and for neutral and congruent trials when preceded by neutral trials. In contrast to the comparison group, at-risk adolescents failed to display a response time advantage for incongruent trials preceded by an incongruent trial. When removing subjects with attention-deficit hyperactivity disorder (ADHD), differences between groups in response time fell below significant level, but a difference in sequence modulation remained significant. Subjects at risk for bipolar disorder also displayed greater intra-subject response time variability for incongruent and congruent trials compared with the comparison adolescents. No differences in response accuracy were observed between groups. Adolescents at risk for developing bipolar disorder displayed specific deficits in cognitive flexibility, which might be useful as a potential marker related to the development of bipolar disorder. © 2013 John Wiley and Sons A/S. Published by Blackwell Publishing Ltd.

  4. Abnormal error monitoring in math-anxious individuals: evidence from error-related brain potentials.

    Directory of Open Access Journals (Sweden)

    Macarena Suárez-Pellicioni

    Full Text Available This study used event-related brain potentials to investigate whether math anxiety is related to abnormal error monitoring processing. Seventeen high math-anxious (HMA and seventeen low math-anxious (LMA individuals were presented with a numerical and a classical Stroop task. Groups did not differ in terms of trait or state anxiety. We found enhanced error-related negativity (ERN in the HMA group when subjects committed an error on the numerical Stroop task, but not on the classical Stroop task. Groups did not differ in terms of the correct-related negativity component (CRN, the error positivity component (Pe, classical behavioral measures or post-error measures. The amplitude of the ERN was negatively related to participants' math anxiety scores, showing a more negative amplitude as the score increased. Moreover, using standardized low resolution electromagnetic tomography (sLORETA we found greater activation of the insula in errors on a numerical task as compared to errors in a non-numerical task only for the HMA group. The results were interpreted according to the motivational significance theory of the ERN.

  5. Classification of lithological units based on geophysical borehole logging - data from the Stripa mine

    International Nuclear Information System (INIS)

    Triumf, C.A.

    1992-06-01

    At the Crosshole site, located at the 360 m level in the Stripa mine, six boreholes F1-F6 have been drilled in a fanlike fashion. To achieve further knowledge of the geological conditions in the rock volumes outside the major tectonized zones, a classification of the pseudo-lithology has been carried out using data from boreholes F3-F6. The analysis has been supported by determination of density and magnetic susceptibility on core samples from boreholes F1-F5. This study demonstrates that the bulk of the tectonically less disturbed rock, forming the matrix in a network of dominant tectonical features, can be considered as homogeneous according to the silicate density. Three volumes with deviating lithology have however been identified in more than one borehole. Furthermore narrow sections are encountered, showing mineralogical, and probably also, micro-structural deviations from the normal granite. These narrow sections are irregularly spread along the boreholes. Their irregular distribution and narrowness, prevents correlation between boreholes. The result of the lithology identification is displayed using a modified Briggs cube. The method used in this project is applicable in many stages of an investigation programme where different disciplines are co-operating and partly complex information must be passed between individuals. (au)

  6. Implication of new CEC recommendations for individual monitoring for external radiation doses to the skin and the extremities

    International Nuclear Information System (INIS)

    Christensen, P.; Julius, H.W.; Marshall, T.O.

    1991-01-01

    A drafting group consisting of the above authors has assisted the CEC in revising the CEC document Technical Recommendations for Monitoring the Exposure to Individuals to External Radiation, EUR 5287, published in 1975. The paper highlights sections of the revised version relating particularly to irradiation of the skin and the extremities and focusses on problems connected to exposure to weakly penetrating radiations. Concepts of individual monitoring for external radiation exposures to the skin of the whole body and to the extremities are discussed and guidance is given as regards dose quantities and dosemeter calibration procedures. A method of quantifying the overall accuracy of the dose measurements as a result of the various uncertainty components connected with the dosimetry system is suggested and requirements on the accuracy of the dose measurements complying with the ICRP requirements on overall accuracy for individual monitoring are specified. Moreover, implications of the accuracy requirements for the design and type testing of the dosemeter are discussed. (author)

  7. Individual medicine in inflammatory bowel disease: monitoring bioavailability, pharmacokinetics and immunogenicity of anti-tumour necrosis factor-alpha antibodies

    DEFF Research Database (Denmark)

    Bendtzen, Klaus; Ainsworth, Mark; Steenholdt, Casper

    2009-01-01

    (s) for these response failures are not clear but inter-individual and even intra-individual differences in bioavailability and pharmacokinetics may contribute. Furthermore, immunogenicity of the drugs, causing patients to develop anti-drug antibodies (ADAs), contributes to treatment failure. Monitoring patients...... for circulating levels of functional anti-TNF drugs and ADAs is therefore warranted so that treatment can be tailored to the individual patient (individual medicine or personal medicine) in order that effective and economical long-term therapy can be given with minimal risks to the patients....

  8. Study on sealing of boreholes

    International Nuclear Information System (INIS)

    1987-01-01

    A bibliographical research on the problem of the backfilling and sealing of boreholes, shafts and tunnels for radioactive waste disposal has been carried out. Various materials - both natural and artificial - like clay, industrial cement, polymer concrete, geothermical and magnesium cement have been examined. Their main physico-chemical and durability characteristics have been examined. The problem of the interaction between the sealing and the geological environment has been also dealt. The final subject discussed in the bibliography is the damage caused to the host formation by the excavation of shafts and tunnels. The laboratory tests have been performed on a natural clay and other types of material (cement grout, cement grout with expansive additive, cement mortar and remoulded clay) which have been used as plug materials. The main conclusions obtained from the tests are the following: - The permeability of the cement is lower than the permeability of the clay; - no adhesion was observed between clay and cement mortar, with or without expansive additive, when cured under different ambient conditions, but without any application of load; - When curing took place under load, good adhesion was observed between the clay and the cement mortar; - The flow of water in a specimen consisting of a clay core surrounded by remoulded clay is larger than in the natural clay. These results seem to be caused by the different permeabilities of the remoulded and undisturbed clay and not to depend on flow at the contact between the two materials. A remote instrumentation package for the in situ evaluation of the performance of a plug, has been developed. In order to get rid of the uncertainty associated with the infiltration of the cables through the plug a wireless data transmission system, based on acoustic waves, has been developed

  9. Self-Monitoring Using Continuous Glucose Monitors with Real-Time Feedback Improves Exercise Adherence in Individuals with Impaired Blood Glucose: A Pilot Study.

    Science.gov (United States)

    Bailey, Kaitlyn J; Little, Jonathan P; Jung, Mary E

    2016-03-01

    Exercise helps individuals with prediabetes or type 2 diabetes (T2D) manage their blood glucose (BG); however, exercise adherence in this population is dismal. In this pilot study we tested the efficacy of a self-monitoring group-based intervention using continuous glucose monitors (CGMs) at increasing exercise adherence in individuals with impaired BG. Thirteen participants with prediabetes or T2D were randomized to an 8-week standard care exercise program (CON condition) (n = 7) or self-monitoring exercise intervention (SM condition) (n = 6). Participants in the SM condition were taught how to self-monitor their exercise and BG, to goal set, and to use CGM to observe how exercise influences BG. We hypothesized that compared with the CON condition, using a real-time CGM would facilitate self-monitoring behavior, resulting in increased exercise adherence. Repeated-measures analysis of variance revealed significant Condition × Time interactions for self-monitoring (P goal setting (P = 0.01), and self-efficacy to self-monitor (P = 0.01), such that the SM condition showed greater increases in these outcomes immediately after the program and at the 1-month follow-up compared with the CON condition. The SM condition had higher program attendance rates (P = 0.03), and a greater proportion of participants reregistered for additional exercise programs (P = 0.048) compared with the CON condition. Participants in both conditions experienced improvements in health-related quality of life, waist circumference, and fitness (P values exercise behavior in individuals living with prediabetes or T2D.

  10. Implication of new CEC recommendations for individual monitoring for external radiation doses to the skin and the extremities

    DEFF Research Database (Denmark)

    Christensen, P.; Julius, H.W.; Marshall, T.O.

    1991-01-01

    A drafting group consisting of the above authors has assisted the CEC in revising the CEC document Technical Recommendations for Monitoring the Exposure to Individuals to External Radiation, EUR 5287, published in 1975. The paper highlights sections of the revised version relating particularly...... to irradiation of the skin and the extremities and focusses on problems connected to exposure to weakly penetrating radiations. Concepts of individual monitoring for external radiation exposures to the skin of the whole body and to the extremities are discussed and guidance is given as regards dose quantities...

  11. Optimal experimental design for placement of boreholes

    Science.gov (United States)

    Padalkina, Kateryna; Bücker, H. Martin; Seidler, Ralf; Rath, Volker; Marquart, Gabriele; Niederau, Jan; Herty, Michael

    2014-05-01

    Drilling for deep resources is an expensive endeavor. Among the many problems finding the optimal drilling location for boreholes is one of the challenging questions. We contribute to this discussion by using a simulation based assessment of possible future borehole locations. We study the problem of finding a new borehole location in a given geothermal reservoir in terms of a numerical optimization problem. In a geothermal reservoir the temporal and spatial distribution of temperature and hydraulic pressure may be simulated using the coupled differential equations for heat transport and mass and momentum conservation for Darcy flow. Within this model the permeability and thermal conductivity are dependent on the geological layers present in the subsurface model of the reservoir. In general, those values involve some uncertainty making it difficult to predict actual heat source in the ground. Within optimal experimental the question is which location and to which depth to drill the borehole in order to estimate conductivity and permeability with minimal uncertainty. We introduce a measure for computing the uncertainty based on simulations of the coupled differential equations. The measure is based on the Fisher information matrix of temperature data obtained through the simulations. We assume that the temperature data is available within the full borehole. A minimization of the measure representing the uncertainty in the unknown permeability and conductivity parameters is performed to determine the optimal borehole location. We present the theoretical framework as well as numerical results for several 2d subsurface models including up to six geological layers. Also, the effect of unknown layers on the introduced measure is studied. Finally, to obtain a more realistic estimate of optimal borehole locations, we couple the optimization to a cost model for deep drilling problems.

  12. New ICRU quantities for the environmental and individual monitoring. Standardization of individual dosemeters by using external beams of photon radiation; Nuevas magnitudes ICRU para la vigilancia radiologica ambiental e individual. Calibracion de dosimetros personales usando haces externos de fotones

    Energy Technology Data Exchange (ETDEWEB)

    Brosed, A; Delgado, A; Granados, C E

    1987-07-01

    The quantities introduced by ICRU for the radiological monitoring are commented, specially those implied in individual protection against external photons. A procedure is proposed in order to standardize the individual dosemeters by using the kerma in air references of CIEMAT-JEN. The reference radiation beams are described in connection with ISO standards. Provisional values are selected for the appropriate conversion and correction factors. (Author) 23 refs.

  13. Final disposal in deep boreholes using multiple geological barriers. Digging deeper for safety. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Bracke, Guido; Hurst, Stephanie; Merkel, Broder; Mueller, Birgit; Schilling, Frank

    2016-03-15

    The proceedings of the workshop on final disposal in deep boreholes using multiple geological barriers - digging deeper for safety include contributions on the following topics: international status and safety requirements; geological and physical barriers; deep drilling - shaft building; technical barriers and emplacement technology for high P/T conditions; recovery (waste retrieval); geochemistry and monitoring.

  14. Core drilling of deep borehole OL-KR43 at Olkiluoto in Eurajoki 2006

    Energy Technology Data Exchange (ETDEWEB)

    Niinimaeki, R. [Suomen Malmi Oy, Espoo (Finland)

    2006-12-15

    Posiva Oy submitted an application to the Finnish Government in May 1999 for the Decision in Principle to choose Olkiluoto in the municipality of Eurajoki as the site of the final disposal facility for spent nuclear fuel. A positive decision was made at the end of 2000 by the Government. The Finnish Parliament ratified the decision in May 2001. The decision makes it possible for Posiva to focus the confirming bedrock investigations at Olkiluoto, where in the next few years an underground rock characterisation facility, ONKALO, will be constructed. As a part of the investigations Suomen Malmi Oy (Smoy) core drilled 1000.26 m and 45.01 m deep boreholes with a diameter of 75.7 mm at Olkiluoto in July - October 2006. The identification numbers of the boreholes are OL-KR43 and OL-KR43B, respectively. A set of monitoring measurements and samplings from the drilling and returning water was carried out during the drilling. Both the volume and the electric conductivity of the drilling water and the returning water were recorded. The drill rig was computer controlled and during drilling the computer recorded drilling parameters. The objective of all these measurements was to obtain more information about bedrock and groundwater properties. Sodium fluorescein was used as a label agent in the drilling water. The total volumes of the used drilling and flushing water were 1103 m{sup 3} and 16 m{sup 3} in boreholes OL-KR43 and OL-KR43B, respectively. Measured volumes of the returning water were 916m{sup 3} in borehole OL-KR43 and 13m{sup 3} in borehole OL-KR43B. The deviation of the boreholes was measured with the deviation measuring instruments EMS and Maxibor. Uniaxial compressive strength, Young's Modulus and Poisson's ratio were measured from the core samples. The average uniaxial compressive strength is about 131 MPa, the average Young's Modulus is 37 GPa and the average Poisson's ratio is 0.19. The main rock types are veined gneiss, diatexitic gneiss

  15. Core drilling of deep borehole OL-KR46 at Olkiluoto in Eurajoki 2007

    International Nuclear Information System (INIS)

    Toropainen, V.

    2007-09-01

    Posiva Oy submitted an application to the Finnish Government in May 1999 for the Decision in Principle to choose Olkiluoto in the municipality of Eurajoki as the site of the final disposal facility for spent nuclear fuel. A positive decision was made at the end of 2000 by the Government. The Finnish Parliament ratified the decision in May 2001. The decision makes it possible for Posiva to focus the confirming bedrock investigations at Olkiluoto, where in the next few years an underground rock characterisation facility, ONKALO, will be constructed. As a part of the investigations Suomen Malmi Oy (Smoy) core drilled 600.10 m and 45.16 m deep boreholes with a diameter of 75.7 mm at Olkiluoto in May - June 2007. The identification numbers of the boreholes are OL-KR46 and OL-KR46B, respectively. A set of monitoring measurements and samplings from the drilling and returning water was carried out during the drilling. Both the volume and the electric conductivity of the returning water, and the volume of drilling water were recorded. The drill rig was computer controlled and during drilling the computer recorded drilling parameters. The objective of all these measurements was to obtain more information about bedrock and groundwater properties. Sodium fluorescein was used as a label agent in the drilling water. The total volumes of the used drilling and flushing water were 466 m 3 and 20 m 3 in boreholes OL-KR46 and OL-KR46B, respectively. Measured volumes of the returning water were 407 m 3 in borehole OL-KR46 and 12 m 3 in borehole OL-KR46B. The deviation of the boreholes was measured with the deviation measuring instruments EMS and Maxibor. Uniaxial compressive strength, Young's Modulus and Poisson's ratio were measured from the core samples. The average uniaxial compressive strength is 116.5 MPa, the average Young's Modulus is 31.5 GPa and the average Poisson's ratio is 0.20. The main rock types are veined gneiss, tonalitic-granodioritic-granitic gneiss and pegmatite

  16. BOSS: Borehole Disposal of Disused Sealed Sources. A Technical Manual

    International Nuclear Information System (INIS)

    2011-01-01

    The management of disused radioactive sources is the responsibility of individual Member States. Accordingly, interest in technologies to allow the safe, secure and sustainable management of disused sealed radioactive sources is growing. This publication is a technical summary on preparing and planning predisposal and disposal activities with regard to the BOSS (borehole disposal of disused sealed sources) system, a safe, simple and cost effective solution for the management of disused sealed radioactive sources. It advises potential implementers and decision makers on the implementation of BOSS, which is expected to provide Member States with a successful tool to contribute to the safety and security of current and future generations.

  17. The Role of Self-Monitoring in Assessing Individual Students' Quantity and Quality of Comments in Large-Class Discussion

    Science.gov (United States)

    Carstens, B. A.; Wright, J. M.; Coles, J. T.; McCleary, L. N.; Williams, R. L.

    2013-01-01

    This study developed a reliable and valid self-monitoring procedure for student use in recording and rating the quality of their individual comments in large college classes. Students used daily record cards immediately to record and rate each comment they made each day. However, a limit was set on the amount of credit students could claim for…

  18. Individual Self-Monitoring & Peer-Monitoring in One Classroom in Writing Activities: Who Is at Disadvantage?

    Science.gov (United States)

    Toofan, Zohreh Zare

    2014-01-01

    Writing is an important experience through which we are able to share ideas, arouse feelings, persuade and convince other people (white & Arndt, 1991). It is important to view writing not solely as the product of an individual, but as a cognitive, social and cultural act. Writing is an act that takes place within a context, that accomplishes a…

  19. Installation of borehole seismometer for earthquake characteristics in deep geological environment

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dong Hee; Choi, Weon Hack; Cho, Sung Il; Chang, Chun Joong [KHNP CRI, Seoul (Korea, Republic of)

    2014-10-15

    Deep geological disposal is currently accepted as the most appropriate method for permanently removing spent nuclear fuel from the living sphere of humans. For implementation of deep geological disposal, we need to understand the geological changes that have taken place over the past 100,000 years, encompassing active faults, volcanic activity, elevation, ubsidence, which as yet have not been considered in assessing the site characteristics for general facilities, as well as to investigate and analyze the geological structures, fracture systems and seismic responses regarding deep geological environment about 500 meters or more underground. In regions with high seismic activity, such as Japan, the Western United States and Taiwan, borehole seismometers installed deep underground are used to monitor seismic activity during the course of seismic wave propagation at various depths and to study the stress changes due to earthquakes and analyze the connection to fault movements. Korea Hydro and Nuclear Power Co., Ltd. (KHNP) have installed the deep borehole earthquake observatory at depths of about 300 to 600 meters in order to study the seismic response characteristics in deep geological environment on June, 2014 in Andong area. This paper will show the status of deep borehole earthquake observatory and the results of background noise response characteristics of these deep borehole seismic data as a basic data analysis. We present here the status of deep borehole seismometer installation by KHNP. In order to basic data analysis for the borehole seismic observation data, this study shows the results of the orientation of seismometer and background noise characteristics by using a probability density function. Together with the ground motion data recorded by the borehole seismometers can be utilized as basic data for seismic response characteristics studies with regard to spent nuclear fuel disposal depth and as the input data for seismic hazard assessment that

  20. Application of borehole geophysics to fracture identification and characterization in low porosity limestones and dolostones

    International Nuclear Information System (INIS)

    Haase, C.S.; King, H.L.

    1986-01-01

    Geophysical logging was conducted in exploratory core holes drilled for geohydrological investigations at three sites used for waste disposal on the US Department of Energy's Oak Ridge Reservation. Geophysical log response was calibrated to borehole geology using the drill core. Subsequently, the logs were used to identify fractures and fractured zones and to characterize the hydrologic activity of such zones. Results of the study were used to identify zones of ground water movement and to select targets for subsequent piezometer and monitoring well installation. Neutron porosity, long- and short-normal resistivity, and density logs exhibit anomalies only adjacent to pervasively fractured zones and rarely exhibit anomalies adjacent to individual fractures, suggesting that such logs have insufficient resolution to detect individual fractures. Spontaneous potential, single point resistance, acoustic velocity, and acoustic variable density logs, however, typically exhibit anomalies adjacent to both individual fractures and fracture zones. Correlation is excellent between fracture density logs prepared from the examination of drill core and fractures identified by the analysis of a suite of geophysical logs that have differing spatial resolution characteristics. Results of the study demonstrate the importance of (1) calibrating geophysical log response to drill core from a site, and (2) running a comprehensive suite of geophysical logs that can evaluate both large- and small-scale rock features. Once geophysical log responses to site-specific geological features have been established, logs provide a means of identifying fracture zones and discriminating between hydrologically active and inactive fracture zones. 9 figs

  1. VTT test borehole for bedrock investigations

    International Nuclear Information System (INIS)

    Okko, O.; Hassinen, P.; Front, K.

    1994-02-01

    A borehole of depth 150 m and diameter 56 mm has been drilled in the area adjacent to the premises of the Technical Research Centre of Finland (VTT) at Otaniemi, Espoo, for the purposes of calibrating geophysical measurements devices. This report presents the test results obtained so far and illustrates the processing of these, in which the various measurements are plotted as curves and combinations of curves. The interpretations provided so far consists of analyses of lithological variations, bedrock fracturing, the nature and occurrence of fracture zones and groundwater flow patterns. Samples were taken from those parts of the core shown by the borehole measurements to be homogenous and thin sections made from these for mineralogical determinations. The rock mechanical and petrophysical properties of the same points were examined. The core is in the possession of VTT, and the hole itself is available to outsiders for the calibration and testing of borehole measurement equipment. (orig.). (21 refs., 13 figs., 5 tabs.)

  2. Developments of borehole strain observation outside China

    Institute of Scientific and Technical Information of China (English)

    邱泽华; 石耀霖

    2004-01-01

    Borehole strain observation is playing an increasingly important role in the study on the crustal movements. It hasbeen used by many countries such as China, USA, Japan, Peru, Australia, South Africa, Iceland and Italy, in research fields of plate tectonics, earthquake, volcanic eruption, dam safety, oil field subsidence, mining collapse andso on. Borehole strainmeter has been improved rapidly and tends to get more and more components included inone probe. Based on observations by this kind of instruments, studies on seismic strain step, slow earthquake,earthquake precursor and volcanic eruption forecasting have made remarkable achievements. In the coming years,borehole strain observation is going to become one major geodetic means, together with GPS and InSAR.

  3. Excess plutonium disposition: The deep borehole option

    International Nuclear Information System (INIS)

    Ferguson, K.L.

    1994-01-01

    This report reviews the current status of technologies required for the disposition of plutonium in Very Deep Holes (VDH). It is in response to a recent National Academy of Sciences (NAS) report which addressed the management of excess weapons plutonium and recommended three approaches to the ultimate disposition of excess plutonium: (1) fabrication and use as a fuel in existing or modified reactors in a once-through cycle, (2) vitrification with high-level radioactive waste for repository disposition, (3) burial in deep boreholes. As indicated in the NAS report, substantial effort would be required to address the broad range of issues related to deep bore-hole emplacement. Subjects reviewed in this report include geology and hydrology, design and engineering, safety and licensing, policy decisions that can impact the viability of the concept, and applicable international programs. Key technical areas that would require attention should decisions be made to further develop the borehole emplacement option are identified

  4. Individual monitoring for internal exposure of workers - regulation and practice in Hungary

    International Nuclear Information System (INIS)

    Kerekes, A.; Kocsy, G.; Pellet, S.

    2005-01-01

    Full text: Decree of Ministry of Health for the enforcement of the Act on Atomic Energy has put special emphasis on the regulation of monitoring for internal exposure in Hungary. The necessarily general prescription of the Decree 'In case of the possibility or suspicion of incorporating open radioactive substances the affected employee shall be subjected to internal contamination monitoring. The obligation of the internal monitoring shall be determined by the Radiation Hygiene Centre of the National Public Health and Medical Officer's Service' called for a guidance to assist the work of the competent authority. The guide was elaborated on the basis of the IAEA Safety Guide No. RS-G-1.2. According to the Safety Guide the decision factor shall first be determined for the potential radionuclides and practice applied. For routine monitoring the required frequency, method and MDA values, moreover for special monitoring the method and MDA values were derived for over 40 radionuclides considering the following two basic assumptions: the activity remaining in or excreted from the body could be determined by the given measurement method, the possible underestimation of intake shall be less than a factor of three within the monitoring interval. The following prescription of the Decree 'The laboratory performing the monitoring of internal exposure shall be accredited' has raised a conflict in practice. To solve the problem the Guide suggests a two-step monitoring process: a screening measurement for the possible internal contamination performed by the Radiation Protection Service of the workplace by any equipment used in daily practice for investigation of patients, radiation protection purposes, etc., if the result of screening indicates an internal contamination the radiation worker shall be monitored by an accredited laboratory. As an ISO Standard in process has several assumptions differing from the IAEA Safety Guide, e.g. the limitation of 'maximum potential

  5. Site Characterization Of Borehole Disposal Facility (BOSS)

    International Nuclear Information System (INIS)

    Kamarudin Samuding; Mohd Abd Wahab Yusof; Mohd Muzamil; Nazran Harun; Nurul Fairuz Diyana Bahrudin; Ismail, C. Mohamad; Kalam

    2014-01-01

    Site characterization study is one of the major components in assessing the potential site for borehole disposal facility. The main objectives of this study are to obtain the geology, geomorphology, hydrogeology and geochemistry information in order to understand the regional geological setting, its past evolution and likely future natural evolution over the assessment time frame. This study was focused on the geological information, borehole log and hydrogeological information. Geological information involve general geology, lineament, topography, structure geology, geological terrain. Whereas Borehole log information consists of lithology, soil and rock formation, gamma logging data and physical properties of soil and rock. Hydrogeological information was emphasized on the groundwater flow, physical parameter as well as geochemical data. Geological mapping shows the study area is underlain by metamorphic rock of the Kenny Hill Formation. Lithologically, it composed of psammitic schist of sandstone origin and phyllite. Based on the borehole log profile, the study area is covered by thick layer of residual soil and estimated not less than 10 m. Those foliated rocks tend to break or split along the foliation planes. The foliation or schistosity may also serve as conduit for groundwater migration. Main structural geology features in the study area trend predominantly in North to Northeast directions. Major fault, the UKM Fault trends in NE-SW direction about 0.5 km located to the east of the proposed borehole site. The groundwater flow direction is influenced by the structure and bedding of the rock formation. Whereas the groundwater flow velocity in the borehole ranges 2.15 - 5.24 x 10 -4 m/ sec. All the data that are obtained in this study is used to support the Safety Assessment and Safety Case report. (author)

  6. Borehole radar and BIPS investigations in boreholes at the Boda area

    Energy Technology Data Exchange (ETDEWEB)

    Carlsten, S.; Straahle, A. [GEOSIGMA AB, Uppsala (Sweden)

    2000-12-01

    As part of the studies conducted in the Boda area, measurements with borehole radar, borehole TV (BIPS) and deviation measurements were performed during May 2000. The investigations were carried out in four percussion-drilled boreholes with a total length of 514 m. Two boreholes are vertical and two are directed into and below the cave area. The BIPS measurement showed the presence of 14 open fractures. Largest apparent aperture width of open fractures was 133 mm. In the lowest part in boreholes 2, 3, and 4, particles in suspension deteriorated the visibility. BIPS has revealed a dominating subhorizontal fracture set and another striking NW to N-S with a dip close to vertical. Possible but very uncertain is a third fracture set striking NE and dipping steeply towards S. The open and partly open fractures forms an average block size 11 m wide and 6 m high, while the length of the block is uncertain. Of 98 borehole radar reflectors interpreted to intersect within BIPS-mapped sections, 90 were possible to combine with BIPS-mapped structures, i.e. 92% of the radar reflectors. The fractured rock around Boda is a shallow feature, since borehole radar and BIPS measurements shows no evidence of increased fracturing or the presence of caves at larger depth in the Boda area. The result indicates that the formation of the superficial fracture system (with caves included) at Boda in all probability is connected to glacial action, such as banking.

  7. Borehole radar and BIPS investigations in boreholes at the Boda area

    International Nuclear Information System (INIS)

    Carlsten, S.; Straahle, A.

    2000-12-01

    As part of the studies conducted in the Boda area, measurements with borehole radar, borehole TV (BIPS) and deviation measurements were performed during May 2000. The investigations were carried out in four percussion-drilled boreholes with a total length of 514 m. Two boreholes are vertical and two are directed into and below the cave area. The BIPS measurement showed the presence of 14 open fractures. Largest apparent aperture width of open fractures was 133 mm. In the lowest part in boreholes 2, 3, and 4, particles in suspension deteriorated the visibility. BIPS has revealed a dominating subhorizontal fracture set and another striking NW to N-S with a dip close to vertical. Possible but very uncertain is a third fracture set striking NE and dipping steeply towards S. The open and partly open fractures forms an average block size 11 m wide and 6 m high, while the length of the block is uncertain. Of 98 borehole radar reflectors interpreted to intersect within BIPS-mapped sections, 90 were possible to combine with BIPS-mapped structures, i.e. 92% of the radar reflectors. The fractured rock around Boda is a shallow feature, since borehole radar and BIPS measurements shows no evidence of increased fracturing or the presence of caves at larger depth in the Boda area. The result indicates that the formation of the superficial fracture system (with caves included) at Boda in all probability is connected to glacial action, such as banking

  8. Characterization of crystalline rocks in deep boreholes. The Kola, Krivoy Rog and Tyrnauz boreholes

    International Nuclear Information System (INIS)

    1992-12-01

    SKB studies, as one alternative, the feasibility of disposing of spent nuclear fuel in very deep boreholes. As a part of this work NEDRA has compiled geoscientific data from three superdeep boreholes within the former Soviet Union. The holes considered were: the Kola borehole, 12261 m deep and located on the Kola Peninsula, the Krivoy Rog borehole, 5000 m deep and located in Ukraine, and the Tyrnauz borehole, 4001 m deep and located between the Black Sea and the Caspian Sea. These boreholes all penetrate crystalline formations, but major differences are found when their tectonic environments are compared. Excluding the uppermost horizon affected by surface phenomena, data do not indicate any general correlation between depth and the state of rock fracturing, which is instead governed by site specific, lithological and tectonical factors. This applies also to fracture zones, which are found at similar frequencies at all depths. As opposed to the structural data, the hydrogeological and hydrochemical information reveals a vertical zonation, with clear similarities between the three boreholes. An upper zone with active circulation and fresh or slightly mineralized groundwaters reaches down 1000-2000 m. The interval from 1000-2000 m down to 4000-5000 m can be characterized as a transition zone with lower circulation rates and gradually increasing mineralisation. Below 4000-5000 m, strongly mineralized, stagnant, juvenile or metamorphogenic waters are found. Geothermal data verify the existence of this zonation. 28 figs, 30 tabs

  9. Borehole tool outrigger arm displacement control mechanism

    International Nuclear Information System (INIS)

    Lee, A.G.

    1985-01-01

    As the outrigger arms of a borehole logging tool are flexed inwardly and outwardly according to the diameter of the borehole opening through which they pass, the corresponding axial displacements of the ends of the arms are controlled to determine the axial positions of the arms relative to the tool. Specifically, as the arm ends move, they are caused to rotate by a cam mechanism. The stiffness of the arms causes the arm ends to rotate in unison, and the exact positions of the arms on the tool are then controlled by the differential movements of the arm ends in the cams

  10. Intercomparison of performance characteristics of OSLDs and TLDs used for individual monitoring

    International Nuclear Information System (INIS)

    Meye, Phillipe Ondo

    2016-07-01

    This research work performed an intercomparison on some important performance characteristics of optically stimulated luminescence (OSL) and thermoluminescence (TL) dosimetry systems used by dosimetry services in Gabon and Ghana, respectively. The study verified the status of the selected performance indicators and propose ways to improve the performances of individual monitoring services of Ghana and Gabon if found necessary. The performance indicators assessed included the zero - dose, the minimum detectability and some important reader performance characteristics. These tests were performed using statistical and experimental methods. The overall uncertainty in measurement of the dosimetry systems of Ghana and Gabon for Hp(10) was determined using the IEC technical report TR 62461, and comparisons were carried out with IAEA 99, PTB 99, IEC 1066 and IEC1283 series performance standards. The IEC 62387 standard was used to assess the linearity dependence of the response and the coefficient of variation of the two dosimetry systems. For the Harshaw TLD 6600 system of the dosimetry service of Ghana, the Reference light QC test meets the requirement given in the user manual. For the OSL system microStar of the dosimetry system of Gabon, the three QC tests, DRK count, CAL count and LED count, meet the user manual requirements. However all these tests failed the statistical test that is part of counting statistics. This led to the conclusion that there may be some abnormalities in the counting system, and that the statistical abnormalities suspected have apparently no impact on the results of the reading. It was also concluded that since the DRK count and the CAL count failed the Chi - squared test by very small margin, a Gaussian distribution could still be considered as an approximation of the experimental data distributions of these two QC measurements. The zero dose for the Harshaw 6600 and the microStar system were found to be 0.026 mSv and 0.08 mSv respectively

  11. Development of in vitro techniques for individual monitoring of {sup 32}P; Desenvolvimento de tecnicas in vitro para monitoracao individual de {sup 32}P

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, A.P.F.; Sousa, W.O.; Dantas, A.L.A.; Dantas, B.M., E-mail: adantas@ird.gov.br, E-mail: wander@ird.gov.br, E-mail: bmdantas@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Divisao de Dosimetria

    2016-07-01

    The {sup 32}P is used in the form of liquid unsealed sources in medical facilities, research and teaching, representing a risk of internal exposure in routine activities and in case of accidental incorporation. The evaluation of {sup 32}P incorporation can be accomplished through in vitro bioanalysis of urine. This paper aims to provide a methodology to analyze {sup 32}P in biological samples, applicable to internal individual monitoring using liquid scintillation technique. The minimum detectable activity of the system was determined and the sensitivity of the technique was evaluated, based on the detected minimum effective dose. (author)

  12. A novel muon detector for borehole density tomography

    Science.gov (United States)

    Bonneville, Alain; Kouzes, Richard T.; Yamaoka, Jared; Rowe, Charlotte; Guardincerri, Elena; Durham, J. Matthew; Morris, Christopher L.; Poulson, Daniel C.; Plaud-Ramos, Kenie; Morley, Deborah J.; Bacon, Jeffrey D.; Bynes, James; Cercillieux, Julien; Ketter, Chris; Le, Khanh; Mostafanezhad, Isar; Varner, Gary; Flygare, Joshua; Lintereur, Azaree T.

    2017-04-01

    Muons can be used to image the density of materials through which they pass, including geological structures. Subsurface applications of the technology include tracking fluid migration during injection or production, with increasing concern regarding such timely issues as induced seismicity or chemical leakage into aquifers. Current density monitoring options include gravimetric data collection and active or passive seismic surveys. One alternative, or complement, to these methods is the development of a muon detector that is sufficiently compact and robust for deployment in a borehole. Such a muon detector can enable imaging of density structure to monitor small changes in density - a proxy for fluid migration - at depths up to 1500 m. Such a detector has been developed, and Monte Carlo modeling methods applied to simulate the anticipated detector response. Testing and measurements using a prototype detector in the laboratory and shallow underground laboratory demonstrated robust response. A satisfactory comparison with a large drift tube-based muon detector is also presented.

  13. Comprehensive borehole management for shorter drilling time; Umfassendes Bohrfortschrittsmanagement zur Verkuerzung der Bohrprojektdauer

    Energy Technology Data Exchange (ETDEWEB)

    Roehrlich, M. [ExxonMobil Production Deutschland GmbH, Hannover (Germany)

    2007-09-13

    In 2006, the trademarked ExxonMobil Fast Drill Process (FDP) was introduced also in the German ExxonMobil boreholes. The process is to maximize the drilling speed for every meter drilled. The process makes it possible to ensure borehole management on the basis of quantitative data and in consideration of all phases that are relevant for sinking a borehole. The FDP is used world-wide in all ExxonMobil drilling departments. More than 1.35 million meters are drilled annually in many different boreholes with different geological conditions, drilling profiles and international sites. The results were similar in many cases, with a significant increase in ROP and drill bit life, and with less damage caused by vibrations. FDP was developed on the basis of real time monitoring of the specific mechanical energy (MSE) required for drilling. MSE monitoring was found to be an effective tool dor detecting inefficient functioning of the drill bit and the overall system. To make operation more efficient, the causes must be identified and measures must be taken accordingly, taking into account the potential risks involved in such measures. MSE monitoring is a tool while FDPL is a broad management process ensuring that MSE and many other data sources are used effectively for optimisation of the ROP. Consequent implementation of the process resulted in a significant increase of the ROP. The major elements required for achieving this goal are discussed. (orig.)

  14. Contamination of estuaries from failing septic tank systems: difficulties in scaling up from monitored individual systems to cumulative impact.

    Science.gov (United States)

    Geary, Phillip; Lucas, Steven

    2018-02-03

    Aquaculture in many coastal estuaries is threatened by diffuse sources of runoff from different land use activities. The poor performance of septic tank systems (STS), as well as runoff from agriculture, may contribute to the movement of contaminants through ground and surface waters to estuaries resulting in oyster contamination, and following their consumption, impacts to human health. In monitoring individual STS in sensitive locations, it is possible to show that nutrients and faecal contaminants are transported through the subsurface in sandy soils off-site with little attenuation. At the catchment scale however, there are always difficulties in discerning direct linkages between failing STS and water contamination due to processes such as effluent dilution, adsorption, precipitation and vegetative uptake. There is often substantial complexity in detecting and tracing effluent pathways from diffuse sources to water bodies in field studies. While source tracking as well as monitoring using tracers may assist in identifying potential pathways from STS to surface waters and estuaries, there are difficulties in scaling up from monitored individual systems to identify their contribution to the cumulative impact which may be apparent at the catchment scale. The processes which may be obvious through monitoring and dominate at the individual scale may be masked and not readily discernible at the catchment scale due to impacts from other land use activities.

  15. Predicting Seawater Intrusion in Coastal Groundwater Boreholes Using Self-Potential Data

    Science.gov (United States)

    Graham, M.; MacAllister, D. J.; Jackson, M.; Vinogradov, J.; Butler, A. P.

    2017-12-01

    Many coastal groundwater abstraction wells are under threat from seawater intrusion: this is exacerbated in summer by low water tables and increased abstraction. Existing hydrochemistry or geophysical techniques often fail to predict the timing of intrusion events. We investigate whether the presence and transport of seawater can influence self-potentials (SPs) measured within groundwater boreholes, with the aim of using SP monitoring to provide early warning of saline intrusion. SP data collection: SP data were collected from a coastal groundwater borehole and an inland borehole (> 60 km from the coast) in the Seaford Chalk of southern England. The SP gradient in the inland borehole was approximately 0.05 mV/m, while that in the coastal borehole varied from 0.16-0.26 mV/m throughout the monitoring period. Spectral analysis showed that semi-diurnal fluctuations in the SP gradient were several orders of magnitude higher at the coast than inland, indicating a strong influence from oceanic tides. A characteristic decrease in the gradient, or precursor, was observed in the coastal borehole several days prior to seawater intrusion. Modelling results: Hydrodynamic transport and geoelectric modelling suggest that observed pressure changes (associated with the streaming potential) are insufficient to explain either the magnitude of the coastal SP gradient or the semi-diurnal SP fluctuations. By contrast, a model of the exclusion-diffusion potential closely matches these observations and produces a precursor similar to that observed in the field. Sensitivity analysis suggests that both a sharp saline front and spatial variations in the exclusion efficiency arising from aquifer heterogeneities are necessary to explain the SP gradient observed in the coastal borehole. The presence of the precursor in the model depends also on the presence and depth of fractures near the base of the borehole. Conclusions: Our results indicate that SP monitoring, combined with hydrodynamic

  16. comparison of performance of public and private boreholes

    African Journals Online (AJOL)

    User

    comparison of the performance of three categories of boreholes namely: public operated boreholes ... Port Harcourt in River State of Nigeria is a fast developing state. ..... World. Bank. Dujam, Consultants (1988). Nation-wide water. Supply and.

  17. Hydrological and hydrogeochemical investigations in boreholes

    International Nuclear Information System (INIS)

    Carlsson, L.; Olsson, T.

    1985-07-01

    Underground investigations in boreholes are presumed to be an important investigation technique for the detailed design of a final repository for nuclear waste. The siting of the repository will be based on surface investigations, but for detailed investigations when the access shafts are sunk, investigations in underground boreholes from the initial shafts and tunnels will be of importance. The hydrogeological investigations in boreholes aimed at testing and developing of hydrogeological techniques and instruments for use in an underground environment in order to reflect actual working and testing conditions. This report is the final report from the hydrogeological investigations in boreholes, and it summarizes the different activities carried out during the course of the program. Most of the included activities are reported in separate internal reports, and therefore only the most important results are included, together with the experiences and conclusions gained during the investigations. The hydrogeochemical part of the program is in a separate final report, consequently no hydrogeochemical information is in the current report. (Author)

  18. DISTRIBUTION OF BOREHOLES IN RESIDENTIAL LAYOUTS AND ...

    African Journals Online (AJOL)

    IPPIS NAU

    2017-07-01

    Jul 1, 2017 ... Lack of adequate public water supply to the inhabitants of Awka urban area since the urban water supply scheme at Imo ... investigate the distribution pattern of boreholes in some new settlements within the urban area to see whether their ..... The urban sprawl has resulted in the conversion of hitherto rural ...

  19. Method for orienting a borehole core

    International Nuclear Information System (INIS)

    Henry, W.

    1980-01-01

    A method is described for longitudinally orienting a borehold core with respect to the longitudinal axis of the drill string which drilled said borehold core in such a manner that the original longitudinal attitude of said borehold core within the earth may be determined. At least a portion of said borehold core is partialy demagnetized in steps to thereby at least partially remove in steps the artificial remanent magnetism imparted to said borehole core by said drill string. The artifical remanent magnetism is oriented substantially parallel to the longitudinal axis of said drill string. The direction and intensity of the total magnetism of said borehold core is measured at desired intervals during the partial demagnetizing procedure. An artificial remanent magnetism vector is established which extends from the final measurement of the direction and intensity of the total magnetism of said borehole core taken during said partial demagnetizing procedure towards the initial measurement of the direction and intensity of the total magnetism of said borehold core taken during said partial demagnetizing procedure. The borehold core is oriented in such a manner that said artificial remanent magnetism vector points at least substantially downwardly towards the bottom of said borehold core for a borehold in the northern hemisphere and points at least substantailly upwardly towards the top of said borehole core for a borehole in the southern hemisphere

  20. Development of a Wireless Sensor Network for Individual Monitoring of Panels in a Photovoltaic Plant

    Directory of Open Access Journals (Sweden)

    Miguel J. Prieto

    2014-01-01

    Full Text Available With photovoltaic (PV systems proliferating in the last few years due to the high prices of fossil fuels and pollution issues, among others, it is extremely important to monitor the efficiency of these plants and optimize the energy production process. This will also result in improvements related to the maintenance and security of the installation. In order to do so, the main parameters in the plant must be continuously monitored so that the appropriate actions can be carried out. This monitoring should not only be carried out at a global level, but also at panel-level, so that a better understanding of what is actually happening in the PV plant can be obtained. This paper presents a system based on a wireless sensor network (WSN that includes all the components required for such monitoring as well as a power supply obtaining the energy required by the sensors from the photovoltaic panels. The system proposed succeeds in identifying all the nodes in the network and provides real-time monitoring while tracking efficiency, features, failures and weaknesses from a single cell up to the whole infrastructure. Thus, the decision-making process is simplified, which contributes to reducing failures, wastes and, consequently, costs.

  1. Development of a wireless sensor network for individual monitoring of panels in a photovoltaic plant.

    Science.gov (United States)

    Prieto, Miguel J; Pernía, Alberto M; Nuño, Fernando; Díaz, Juan; Villegas, Pedro J

    2014-01-30

    With photovoltaic (PV) systems proliferating in the last few years due to the high prices of fossil fuels and pollution issues, among others, it is extremely important to monitor the efficiency of these plants and optimize the energy production process. This will also result in improvements related to the maintenance and security of the installation. In order to do so, the main parameters in the plant must be continuously monitored so that the appropriate actions can be carried out. This monitoring should not only be carried out at a global level, but also at panel-level, so that a better understanding of what is actually happening in the PV plant can be obtained. This paper presents a system based on a wireless sensor network (WSN) that includes all the components required for such monitoring as well as a power supply obtaining the energy required by the sensors from the photovoltaic panels. The system proposed succeeds in identifying all the nodes in the network and provides real-time monitoring while tracking efficiency, features, failures and weaknesses from a single cell up to the whole infrastructure. Thus, the decision-making process is simplified, which contributes to reducing failures, wastes and, consequently, costs.

  2. Monitoring of peri-operative fluid administration by individualized goal-directed therapy

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, M; Holte, Kathrine; Secher, N H

    2007-01-01

    (n = 725) found a reduced hospital stay. Post-operative nausea and vomiting (PONV) and ileus were reduced in three studies and complications were reduced in four studies. Of the monitors that may be applied for goal-directed therapy, only oesophageal Doppler has been tested adequately; however......, several other options exist. CONCLUSION: Goal-directed therapy with the maximization of flow-related haemodynamic variables reduces hospital stay, PONV and complications, and facilitates faster gastrointestinal functional recovery. So far, oesophageal Doppler is recommended, but other monitors...

  3. Measuring in-situ stress in deep boreholes

    International Nuclear Information System (INIS)

    1985-08-01

    The hydrofracturing method of in-situ stress measurement is the only technique which has been proven to be reliable in boreholes below depths of 300 m. The method has been used in a variety of applications at depths of up to 5000m, and in a range of borehole diameters. The equipment used is composed of standard components from proven and long-established oil industry well-logging tools and is simple to operate. This is preferable to the delicate electrical devices used in the overcoring stress measurement method. Electrical components are difficult to waterproof, very small strains are monitored and the tendency of electrical circuits to drift, due to a variety of effects, makes interpretation of the results difficult. However, the interpretation of hydrofracturing test results is often not easy. Many factors can prevent ideal fracturing behaviour from occurring, in which case conventional analyses will yield incorrect answers. The complete state of stress can often not be determined and sweeping assumptions are commonly made about principal stress direction, which cannot always be subsequently verified. (author)

  4. Electrical resistance tomography using steel cased boreholes as electrodes

    International Nuclear Information System (INIS)

    Newmark, R L; Daily, W; Ramirez, A

    1999-01-01

    Electrical resistance tomography (ERT) using multiple electrodes installed in boreholes has been shown to be useful for both site characterization and process monitoring. In some cases, however, installing multiple downhole electrodes is too costly (e.g., deep targets) or risky (e.g., contaminated sites). For these cases we have examined the possibility of using the steel casings of existing boreholes as electrodes. The first case we investigated used an array of steel casings as electrodes. This results in very few data and thus requires additional constraints to limit the domain of possible inverse solutions. Simulations indicate that the spatial resolution and sensitivity are understandably low but it is possible to coarsely map the lateral extent of subsurface processes such as steam floods. A hybrid case uses traditional point electrode arrays combined with long-conductor electrodes (steel casings). Although this arrangement provides more data, in many cases it results in poor reconstructions of test targets. Results indicate that this method may hold promise for low resolution imaging where steel casings can be used as electrodes

  5. Key Factors to Determine the Borehole Spacing in a Deep Borehole Disposal for HLW

    International Nuclear Information System (INIS)

    Lee, Jongyoul; Choi, Heuijoo; Lee, Minsoo; Kim, Geonyoung; Kim, Kyeongsoo

    2015-01-01

    Deep fluids also resist vertical movement because they are density stratified and reducing conditions will sharply limit solubility of most dose critical radionuclides at the depth. Finally, high ionic strengths of deep fluids will prevent colloidal transport. Therefore, as an alternative disposal concept, i.e., deep borehole disposal technology is under consideration in number of countries in terms of its outstanding safety and cost effectiveness. In this paper, the general concept for deep borehole disposal of spent fuels or high level radioactive wastes which has been developed by some countries according to the rapid advance in the development of drilling technology, as an alternative method to the deep geological disposal method, was reviewed. After then an analysis on key factors for the distance between boreholes for the disposal of HLW was carried out. In this paper, the general concept for deep borehole disposal of spent fuels or HLW wastes, as an alternative method to the deep geological disposal method, were reviewed. After then an analysis on key factors for the determining the distance between boreholes for the disposal of HLW was carried out. These results can be used for the development of the HLW deep borehole disposal system

  6. Key Factors to Determine the Borehole Spacing in a Deep Borehole Disposal for HLW

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jongyoul; Choi, Heuijoo; Lee, Minsoo; Kim, Geonyoung; Kim, Kyeongsoo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Deep fluids also resist vertical movement because they are density stratified and reducing conditions will sharply limit solubility of most dose critical radionuclides at the depth. Finally, high ionic strengths of deep fluids will prevent colloidal transport. Therefore, as an alternative disposal concept, i.e., deep borehole disposal technology is under consideration in number of countries in terms of its outstanding safety and cost effectiveness. In this paper, the general concept for deep borehole disposal of spent fuels or high level radioactive wastes which has been developed by some countries according to the rapid advance in the development of drilling technology, as an alternative method to the deep geological disposal method, was reviewed. After then an analysis on key factors for the distance between boreholes for the disposal of HLW was carried out. In this paper, the general concept for deep borehole disposal of spent fuels or HLW wastes, as an alternative method to the deep geological disposal method, were reviewed. After then an analysis on key factors for the determining the distance between boreholes for the disposal of HLW was carried out. These results can be used for the development of the HLW deep borehole disposal system.

  7. Analyses of the deep borehole drilling status for a deep borehole disposal system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Youl; Choi, Heui Joo; Lee, Min Soo; Kim, Geon Young; Kim, Kyung Su [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The purpose of disposal for radioactive wastes is not only to isolate them from humans, but also to inhibit leakage of any radioactive materials into the accessible environment. Because of the extremely high level and long-time scale radioactivity of HLW(High-level radioactive waste), a mined deep geological disposal concept, the disposal depth is about 500 m below ground, is considered as the safest method to isolate the spent fuels or high-level radioactive waste from the human environment with the best available technology at present time. Therefore, as an alternative disposal concept, i.e., deep borehole disposal technology is under consideration in number of countries in terms of its outstanding safety and cost effectiveness. In this paper, the general status of deep drilling technologies was reviewed for deep borehole disposal of high level radioactive wastes. Based on the results of these review, very preliminary applicability of deep drilling technology for deep borehole disposal analyzed. In this paper, as one of key technologies of deep borehole disposal system, the general status of deep drilling technologies in oil industry, geothermal industry and geo scientific field was reviewed for deep borehole disposal of high level radioactive wastes. Based on the results of these review, the very preliminary applicability of deep drilling technology for deep borehole disposal such as relation between depth and diameter, drilling time and feasibility classification was analyzed.

  8. Serological IgG Testing to Diagnose Alimentary Induced Diseases and Monitoring Efficacy of an Individual Defined Diet in Dogs

    OpenAIRE

    Anne-Margré C. Vink

    2014-01-01

    Background. Food-related allergies and intolerances are frequently occurring in dogs. Diagnosis and monitoring according ‘Golden Standard’ of elimination efficiency is, however, time consuming, expensive, and requires expert clinical setting. In order to facilitate rapid and robust, quantitative testing of intolerance, and determining the individual offending foods, a serological test is implicated for Alimentary Induced Diseases and manifestations. Method. As we developed Medisynx IgG Human ...

  9. Using Data to Individualize a Multicomponent, Technology-Based Self-Monitoring Intervention

    Science.gov (United States)

    Bruhn, Allison Leigh; Vogelgesang, Kari; Fernando, Josephine; Lugo, Wilbeth

    2016-01-01

    Technology in schools is abundant as is the call for evidence-based interventions for students who need additional support to be successful. One promising use of technology is for self-monitoring interventions aimed at improving classroom behavior. In this study, two middle school students with disabilities used a multicomponent, self-monitoring…

  10. Monitoring and assessment of individual doses of occupationally exposed workers due to external radiation

    International Nuclear Information System (INIS)

    Kitaw, S. T.

    2015-05-01

    Exposure to external radiation occurs in many occupations. Any exposure to ionizing radiation has the tendency to change the biochemical make-up of the human body which may result in biological health effects of ionizing radiation. This study reviews the monitoring and assessment of external radiation doses in industrial radiography using thermoluminescence and direct reading dosimeters. Poor handling procedures such as inadequate engineering control of equipment, safety culture, management, and inadequate assessment and monitoring of doses are the causes of most of the reported cases of exposure to external radiation in industrial radiography. Occupational exposure data in industrial radiography from UNSCEAR report 2008 was discussed and recommendations were made to regulatory authorities, operating organizations and radiographers. (au)

  11. Beyond Patient Monitoring: Conversational Agents Role in Telemedicine & Healthcare Support For Home-Living Elderly Individuals

    OpenAIRE

    Fadhil, Ahmed

    2018-01-01

    There is a need for systems to dynamically interact with ageing populations to gather information, monitor health condition and provide support, especially after hospital discharge or at-home settings. Several smart devices have been delivered by digital health, bundled with telemedicine systems, smartphone and other digital services. While such solutions offer personalised data and suggestions, the real disruptive step comes from the interaction of new digital ecosystem, represented by chatb...

  12. Cross-hole fracture connectivity assessed using hydraulic responses during liner installations in crystalline bedrock boreholes

    Science.gov (United States)

    Persaud, Elisha; Levison, Jana; Pehme, Peeter; Novakowski, Kentner; Parker, Beth

    2018-01-01

    In order to continually improve the current understanding of flow and transport in crystalline bedrock environments, developing and improving fracture system characterization techniques is an important area of study. The presented research examines the installation of flexible, impermeable FLUTe™ liners as a means for assessing cross-hole fracture connectivity. FLUTe™ liners are used to generate a new style of hydraulic pulse, with pressure response monitored in a nearby network of open boreholes drilled in gneissic rock of the Canadian Shield in eastern Ontario, Canada. Borehole liners were installed in six existing 10-15 cm diameter boreholes located 10-35 m apart and drilled to depths ranging between 25-45 m. Liner installation tests were completed consecutively with the number of observation wells available for each test ranging between one and six. The collected pressure response data have been analyzed to identify significant groundwater flow paths between source and observation boreholes as well as to estimate inter-well transmissivity and storativity using a conventional type-curve analysis. While the applied solution relies on a number of general assumptions, it has been found that reasonable comparison can be made to previously completed pulse interference and pumping tests. Results of this research indicate areas where method refinement is necessary, but, nonetheless, highlight the potential for use in crystalline bedrock environments. This method may provide value to future site characterization efforts given that it is complementary to, and can be used in conjunction with, other currently employed borehole liner applications, such as the removal of cross-connection at contaminated sites and the assessment of discrete fracture distributions when boreholes are sealed, recreating natural hydraulic gradient conditions.

  13. Subseafloor seawater-basalt-microbe reactions: Continuous sampling of borehole fluids in a ridge flank environment

    Science.gov (United States)

    Wheat, C. Geoffrey; Jannasch, Hans W.; Fisher, Andrew T.; Becker, Keir; Sharkey, Jessica; Hulme, Samuel

    2010-07-01

    Integrated Ocean Drilling Program (IODP) Hole 1301A was drilled, cased, and instrumented with a long-term, subseafloor observatory (CORK) on the eastern flank of the Juan de Fuca Ridge in summer 2004. This borehole is located 1 km south of ODP Hole 1026B and 5 km north of Baby Bare outcrop. Hole 1301A penetrates 262 m of sediment and 108 m of the uppermost 3.5 Ma basaltic basement in an area of warm (64°C) hydrothermal circulation. The borehole was instrumented, and those instruments were recovered 4 years later. Here we report chemical data from two continuous fluid samplers (OsmoSamplers) and temperature recording tools that monitored changes in the state of borehole (formation) fluids. These changes document the effects of drilling, fluid overpressure and flow, seawater-basalt interactions, and microbial metababolic activity. Initially, bottom seawater flowed into the borehole through a leak between concentric CORK casing strings. Eventually, the direction of flow reversed, and warm, altered formation fluid flowed into the borehole and discharged at the seafloor. This reversal occurred during 1 week in September 2007, 3 years after drilling operations ceased. The composition of the formation fluid around Hole 1301A generally lies within bounds defined by springs on Baby Bare outcrop (to the south) and fluids that discharged from Hole 1026B (to the north); deviations likely result from reactions with drilling products. Simple conservative mixing of two end-member fluids reveals reactions occurring within the crust, including nitrate reduction presumably by denitrifying microbes. The observed changes in borehole fluid composition provide the foundation for a conceptual model of chemical and microbial change during recharge of a warm ridge-flank hydrothermal system. This model can be tested through future scientific ocean drilling experiments.

  14. Individualized guidance and telephone monitoring in a self-supervised home-based physiotherapeutic program in Parkinson

    Directory of Open Access Journals (Sweden)

    Ihana Thaís Guerra de Oliveira Gondim

    Full Text Available Abstract Introduction: Home therapeutic exercises have been a target of interest in the treatment of the Parkinson's disease (PD. The way that the physical therapist guides and monitors these exercises can impact the success of therapy. Objective: To evaluate the effects of individualized orientation and monitoring by telephone in a self-supervised home therapeutic exercise program on signs and symptoms of PD and quality of life (QoL. Methods: Single-blind randomized clinical trials with 28 people with PD (Hoehn and Yahr 1 to 3. Patients were randomized into two groups: experimental and control. The experimental group had a meeting with individualized guidance about physiotherapy exercises present in a manual, received the manual to guide their activities at home and obtained subsequent weekly monitoring by telephone. The control group received the usual cares by the service. Both were orientated to carry out exercises three times a week during 12 weeks. Was evaluated: (1 activities of daily living (ADL and motor examination sections of the Unified Parkinson's Disease Rating Scale (UPDRS and QoL by the Parkinson Disease Questionnaire 39 (PDQ-39. The analysis between groups was performed by the Mann-Whitney test and intragroup through the Wilcoxon (p < 0.05. Results: Significant improvement in ADL (p= 0.001 and motor examination (p= 0.0008 of the UPDRS, PDQ-39 total (p = 0.027 and dimensions mobility (p = 0.027, emotional well-being (p= 0.021 and bodily discomfort (p = 0.027 in the experimental group compared to the control group. Conclusion: The individualized guidance and weekly monitoring by telephone in a self-supervised home therapeutic exercises program promoted positive effects on ADL, motor examination and QoL of people in early stages of PD.

  15. Individual and Group-Based Engagement in an Online Physical Activity Monitoring Program in Georgia.

    Science.gov (United States)

    Smith, Matthew Lee; Durrett, Nicholas K; Bowie, Maria; Berg, Alison; McCullick, Bryan A; LoPilato, Alexander C; Murray, Deborah

    2018-06-07

    Given the rising prevalence of obesity in the United States, innovative methods are needed to increase physical activity (PA) in community settings. Evidence suggests that individuals are more likely to engage in PA if they are given a choice of activities and have support from others (for encouragement, motivation, and accountability). The objective of this study was to describe the use of the online Walk Georgia PA tracking platform according to whether the user was an individual user or group user. Walk Georgia is a free, interactive online tracking platform that enables users to log PA by duration, activity, and perceived difficulty, and then converts these data into points based on metabolic equivalents. Users join individually or in groups and are encouraged to set weekly PA goals. Data were examined for 6,639 users (65.8% were group users) over 28 months. We used independent sample t tests and Mann-Whitney U tests to compare means between individual and group users. Two linear regression models were fitted to identify factors associated with activity logging. Users logged 218,766 activities (15,119,249 minutes of PA spanning 592,714 miles [41,858,446 points]). On average, group users had created accounts more recently than individual users (P < .001); however, group users logged more activities (P < .001). On average, group users logged more minutes of PA (P < .001) and earned more points (P < .001). Being in a group was associated with a larger proportion of weeks in which 150 minutes or more of weekly PA was logged (B = 20.47, P < .001). Use of Walk Georgia was significantly higher among group users than among individual users. To expand use and dissemination of online tracking of PA, programs should target naturally occurring groups (eg, workplaces, schools, faith-based groups).

  16. Individual recognition of territorial peregrine falcons Falco peregrinus: a key for long-term monitoring programmes.

    Directory of Open Access Journals (Sweden)

    ZUBEROGOITIA, I., ENRIQUE MARTÍNEZ, J., ZABALA, J.

    2013-01-01

    including the shape, length and size of the moustache and the dark marks that extend from the nape to the cheek and neck; design, size, density and distribution of the spots on the breast, throat, neck and cheek; and the colour of the breast and neck. From 1997 to 2013 we identified 83 males and 96 females in 35 territories. We found phenotypic variation among individuals when the combination of the possible subgroups of identification characters was considered, which constitutes an opportunity to recognise individual hawks without marking them with artificial tags.

  17. Drilling, construction, geophysical log data, and lithologic log for boreholes USGS 142 and USGS 142A, Idaho National Laboratory, Idaho

    Science.gov (United States)

    Twining, Brian V.; Hodges, Mary K.V.; Schusler, Kyle; Mudge, Christopher

    2017-07-27

    Starting in 2014, the U.S. Geological Survey in cooperation with the U.S. Department of Energy, drilled and constructed boreholes USGS 142 and USGS 142A for stratigraphic framework analyses and long-term groundwater monitoring of the eastern Snake River Plain aquifer at the Idaho National Laboratory in southeast Idaho. Borehole USGS 142 initially was cored to collect rock and sediment core, then re-drilled to complete construction as a screened water-level monitoring well. Borehole USGS 142A was drilled and constructed as a monitoring well after construction problems with borehole USGS 142 prevented access to upper 100 feet (ft) of the aquifer. Boreholes USGS 142 and USGS 142A are separated by about 30 ft and have similar geology and hydrologic characteristics. Groundwater was first measured near 530 feet below land surface (ft BLS) at both borehole locations. Water levels measured through piezometers, separated by almost 1,200 ft, in borehole USGS 142 indicate upward hydraulic gradients at this location. Following construction and data collection, screened water-level access lines were placed in boreholes USGS 142 and USGS 142A to allow for recurring water level measurements.Borehole USGS 142 was cored continuously, starting at the first basalt contact (about 4.9 ft BLS) to a depth of 1,880 ft BLS. Excluding surface sediment, recovery of basalt, rhyolite, and sediment core at borehole USGS 142 was approximately 89 percent or 1,666 ft of total core recovered. Based on visual inspection of core and geophysical data, material examined from 4.9 to 1,880 ft BLS in borehole USGS 142 consists of approximately 45 basalt flows, 16 significant sediment and (or) sedimentary rock layers, and rhyolite welded tuff. Rhyolite was encountered at approximately 1,396 ft BLS. Sediment layers comprise a large percentage of the borehole between 739 and 1,396 ft BLS with grain sizes ranging from clay and silt to cobble size. Sedimentary rock layers had calcite cement. Basalt flows

  18. Therapeutic drug monitoring for the individualization of docetaxel dosing: a randomized pharmacokinetic study

    NARCIS (Netherlands)

    Engels, Frederike K.; Loos, Walter J.; van der Bol, Jessica M.; de Bruijn, Peter; Mathijssen, Ron H. J.; Verweij, Jaap; Mathot, Ron A. A.

    2011-01-01

    Docetaxel pharmacokinetic (PK) parameters, notably clearance and exposure (AUC), are characterized by large interindividual variability. The purpose of this study was to evaluate the effect of PK-guided [area under the plasma concentration versus time curve (AUC) targeted], individualized docetaxel

  19. Systematic processing of the external individual monitoring data obtained by photographic film and capacitor dosemeters

    International Nuclear Information System (INIS)

    Krueger, F.; Shtuk, D.

    1983-01-01

    Individual radiation load measurements have been carried out both with photographic film and capacitor type dosemeters (CD). Systematic statistics methods were applied for the obtained data processing. The CD data were shown to exceed those measured with the film dosemeters. Specific features of the CD application are revealed that should be taken into account in practice [ru

  20. Individualized treatment of multidrug-resistant tuberculosis using therapeutic drug monitoring

    Directory of Open Access Journals (Sweden)

    Mathieu S Bolhuis

    2016-01-01

    Conclusion: TDM is highly valuable to individualize and optimize treatment of complex MDR-TB patients. TDM is routinely applied in Tuberculosis Center Beatrixoord, and high success rates for treatment of MDR-TB patients have been achieved. DBS and LSS make implementation of TDM feasible, even in low- and middle-income countries.

  1. Towards the disease biomarker in an individual patient using statistical health monitoring

    NARCIS (Netherlands)

    Engel, J.; Blanchet, L.M.; Engelke, U.F.; Wevers, R.A.; Buydens, L.M.

    2014-01-01

    In metabolomics, identification of complex diseases is often based on application of (multivariate) statistical techniques to the data. Commonly, each disease requires its own specific diagnostic model, separating healthy and diseased individuals, which is not very practical in a diagnostic setting.

  2. Monitoring of peri-operative fluid administration by individualized goal-directed therapy

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, M; Holte, Kathrine; Secher, N H

    2007-01-01

    BACKGROUND: In order to avoid peri-operative hypovolaemia or fluid overload, goal-directed therapy with individual maximization of flow-related haemodynamic parameters has been introduced. The objectives of this review are to update research in the area, evaluate the effects on outcome and assess...

  3. Individual monitoring of internal exposure for nuclear medicine workers in Switzerland

    International Nuclear Information System (INIS)

    Baechler, S.; Stritt, N.; Bochud, F. O.

    2011-01-01

    Monitoring of internal exposure for nuclear medicine workers requires frequent measurements due to the short physical half lives of most radionuclides used in this field. The aim of this study was to develop screening measurements performed at the workplace by local staff using standard laboratory instrumentation, to detect whether potential intake has occurred. Such measurements do not enable to determine the committed effective dose, but are adequate to verify that a given threshold is not exceeded. For radioiodine, i.e. 123 I, 124 I, 125 I and 131 I, a calibrated surface contamination monitor is placed in front of the thyroid to detect whether the activity threshold has been exceeded. For radionuclides with very short physical half-lives (≤6 h), such as 99m Tc) and those used in positron emission tomography imaging, i.e. 11 C, 15 O, 18 F and 68 Ga, screening procedures consist in performing daily measurements of the ambient dose rate in front of the abdomen. Other gamma emitters used for imaging, i.e. 67 Ga, 111 In and 201 Tl, are measured with a scintillation detector located in front of the thorax. For pure beta emitters, i.e. 90 Y and 169 Er, as well as beta emitters with low-intensity gamma rays, i.e. 153 Sm, 177 Lu, 186 Re and 188 Re, the procedure consists in measuring hand contamination immediately after use. In Switzerland, screening procedures have been adopted by most nuclear medicine services since such measurements enable an acceptable monitoring while taking into account practical and economic considerations. (authors)

  4. Borehole stoneley waves and permeability: Laboratory results

    International Nuclear Information System (INIS)

    Winkler, K.W.; Plona, T.J.; Froelich, B.; Liu, H.L.

    1987-01-01

    Recent interest in full waveform sonic logging has created the need for full waveform laboratory experiments on model boreholes. Of particular interest is the investigation of Stoneley waves and their interaction with permeable formations. The authors describe experimental results that show how Stoneley wave slowness and attenuation are affected by formation permeability. Both slowness and attenuation (1/Q) are observed to increase with formation permeability. This increase is frequency dependent, being greatest at low frequencies. The presence of simulated mudcakes on the borehole wall reduces the permeability effect on Stoneley waves, but does not eliminate it. The mudcake effect is frequency dependent, being greatest at low frequencies. In our experiments on rocks, the laboratory data is in qualitative agreement with theoretical predictions. In a very well characterized synthetic porous material, theory and experiment are in good quantitative agreement

  5. Borehole instrument for scintillation gamma spectrometer

    International Nuclear Information System (INIS)

    Sinitsyn, A.Ya.; Gabitov, R.M.

    1979-01-01

    Described are a schematic diagram and main specifications of a borehole instrument with autostabilization of energy scale measure by gamma bench-mark of 137 Cs, intended for the application in a logging gamma spectrometer to determine separately the concentrations of nature radioactive elements. The instrument may be connected to the KOBDFM-2 cable of 600 m length. It contains a scintillation counter for gamma quanta consisting of 30x70 mm NaI(Tl) crystal and a FEU-85 photoamplifier, an input conforming stage, a diagram of threshold pulse formation and regulating high-voltage generator. The borehole instrument has been proved under laboratory and field conditions at 10-40 deg C

  6. Routine individual monitoring of aircraft crew exposure; Czech experience and results 1998-2008

    Czech Academy of Sciences Publication Activity Database

    Malušek, Alexandr; Ploc, Ondřej; Kovář, Ivan; Brabcová, Kateřina; Spurný, František

    2011-01-01

    Roč. 144, 1-4 (2011), s. 684-687 ISSN 0144-8420 R&D Projects: GA ČR GA205/09/0171 Grant - others:Evropské společenství ILSRA(XE) FIGM-CT2000-00068 $c; JSPS(JP) P09753 Institutional research plan: CEZ:AV0Z10480505 Keywords : aircraft * crew exposure * monitoring Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.822, year: 2011

  7. Simple routine tests to improve the performance of the DPRSN TLD-based individual monitoring system

    International Nuclear Information System (INIS)

    Alves, J.G.; Batel, V.I.; Silva, P.B.; Roda, A.; Santos, L.

    2002-01-01

    This paper presents some of the results of a simple quality control program developed and implemented at the thermoluminescence sector of the IMS. The European Union (EU) Directive 96/29/EURATOM has not yet been transposed to national legislation and Portuguese law concerning the monitoring of radiation workers still establishes an annual dose limit of 50 mSv. However, new legislation has recently been published with requirements on the performance of dosimetric services. Some of the results of the tests reported herein will show compliance with the above mentioned requirements

  8. Nuclear borehole logging for oil exploration

    International Nuclear Information System (INIS)

    Oelgaard, P.L.

    1989-01-01

    Reactor physics can be applied to the logging of boreholes for the exploration of oil and gas and the results obtained can be interpreted more correctly by use of reactor physics models, e.g. one-dimensional multi-group diffusion theory adapted for gamma quanta. The standard nuclear logging tools are: natural gamma, gamma density, neutron porosity and the pulsed-neutron tool. The models and interpretation procedures are discussed. 1 fig

  9. Borehole Plugging-Materials Development Program

    International Nuclear Information System (INIS)

    Gulick, C.W. Jr.

    1978-06-01

    This report discusses the background and first year's results of the grouting materials development program for plugging boreholes associated with the Nuclear Waste Isolation Pilot Plant. The grouts are to be pumpable, impermeable, and durable for many thousands of years. The work was done at the Concrete Laboratory of the U.S. Army Engineer Waterways Experiment Station (WES), Vicksburg, Mississippi. The workability, strength, porosity, bonding, expansion, and permeability data are summarized and discussed. The work is continuing at WES

  10. Monitoring the thermal performance of a heat pump with borehole heat exchangers in Lugano (TI); Projet: mesure des performances thermiques d'une PAC sur sondes geothermiques a Lugano (TI)

    Energy Technology Data Exchange (ETDEWEB)

    Pahud, D.; Lachal, B.

    2001-07-01

    This report presents a heat pump system installed in a single-family house in Lugano, Switzerland, and the results of its monitoring for nine months. The 14 kW heat pump is meant exclusively for space heating while the domestic hot water is provided by a solar water heater with 7.8 m{sup 2} collector area. The cold source of the heat pump is formed by three 80 m deep underground wells from which the geothermal energy is extracted by water circulation. The installation allows to transfer excess heat from the solar collector to the underground wells. The whole system is equipped with a couple of flow meters, temperature sensors and electric counters, in order to characterise its dynamic response and efficiency. Diagrams show monthly values of the thermal energy extracted from the wells, the energy re-injected to the wells, the energy delivered by the heat pump as well as its electrical energy consumption. The heat pump coefficient of performance, which is roughly 4, is discussed.

  11. Individual monitoring of medical staff working in interventional radiology in Switzerland using double dosimetry

    International Nuclear Information System (INIS)

    Damet, J.; Bailat, C.; Bize, P.; Buchillier, Th.; Tosic, M.; Verdun, F.R.; Baechler, S.

    2011-01-01

    Physicians who frequently perform fluoroscopic examinations are exposed to high intensity radiation fields. The exposure monitoring is performed with a regular personal dosimeter under the apron in order to estimate the effective dose. However, large parts of the body are not protected by the apron (e.g. arms, head). Therefore, it is recommended to wear a supplemental dosimeter over the apron to obtain a better representative estimate of the effective dose. The over-apron dosimeter can also be used to estimate the eye lens dose. The goal of this study was to investigate the relevance of double dosimetry in interventional radiology. First the calibration procedure of the dosimeters placed over the apron was tested. Then, results of double dosimetry during the last five years were analyzed. We found that the personal dose equivalent measured over a lead apron was underestimated by ∼20% to ∼40% for X-ray beam qualities used in radiology. Measurements made over five-year period confirm that the use of a single under-apron dosimeter is inadequate for personnel monitoring. Relatively high skin dose (>10 mSv/month) would have remained undetected without a second dosimeter placed on the apron.

  12. Strategic decision analysis applied to borehole seismology

    International Nuclear Information System (INIS)

    Menke, M.M.; Paulsson, B.N.P.

    1994-01-01

    Strategic Decision Analysis (SDA) is the evolving body of knowledge on how to achieve high quality in the decision that shapes an organization's future. SDA comprises philosophy, process concepts, methodology, and tools for making good decisions. It specifically incorporates many concepts and tools from economic evaluation and risk analysis. Chevron Petroleum Technology Company (CPTC) has applied SDA to evaluate and prioritize a number of its most important and most uncertain R and D projects, including borehole seismology. Before SDA, there were significant issues and concerns about the value to CPTC of continuing to work on borehole seismology. The SDA process created a cross-functional team of experts to structure and evaluate this project. A credible economic model was developed, discrete risks and continuous uncertainties were assessed, and an extensive sensitivity analysis was performed. The results, even applied to a very restricted drilling program for a few years, were good enough to demonstrate the value of continuing the project. This paper explains the SDA philosophy concepts, and process and demonstrates the methodology and tools using the borehole seismology project example. SDA is useful in the upstream industry not just in the R and D/technology decisions, but also in major exploration and production decisions. Since a major challenge for upstream companies today is to create and realize value, the SDA approach should have a very broad applicability

  13. Downhole television (DHTV) applications in borehole plugging

    International Nuclear Information System (INIS)

    Christensen, C.L.; Statler, R.D.; Peterson, E.W.

    1980-05-01

    The Borehole Plugging (BHP) Program is a part of the Sandia experimental program to support the Waste Isolation Pilot Plant (WIPP). The Sandia BHP program is an Office of Nuclear Waste Isolation (ONWI)-funded program designed to provide inputs to the generic plugging program while simultaneously acquiring WIPP-specific data. For this reason a close liaison is maintained between the Sandia WIPP project and the ONWI generic program. Useful technology developed within the Sandia BHP to support WIPP is made available and considered for further development and application to the generic Borehole Plugging and Repository Sealing Program at ONWI. The purpose of this report is to illustrate the usefulness of downhole television (DHTV) observations of a borehole to plan plugging operations. An indication of the wellbore conditions observed is provided. The equipment and setup procedure used in the evaluation of AEC-7 for the Bell Canyon test series are illustrated. A sequence of pictures at various depths as the DHTV rig is lowered through the wellbore is presented. Sample photographs taken with both dry and underwater lamps for illumination are included. The caliper logs for the same depth are included for comparison. General comments are provided on the illustrations

  14. Deep Borehole Field Test Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Ernest L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-09-30

    This report documents conceptual design development for the Deep Borehole Field Test (DBFT), including test packages (simulated waste packages, not containing waste) and a system for demonstrating emplacement and retrieval of those packages in the planned Field Test Borehole (FTB). For the DBFT to have demonstration value, it must be based on conceptualization of a deep borehole disposal (DBD) system. This document therefore identifies key options for a DBD system, describes an updated reference DBD concept, and derives a recommended concept for the DBFT demonstration. The objective of the DBFT is to confirm the safety and feasibility of the DBD concept for long-term isolation of radioactive waste. The conceptual design described in this report will demonstrate equipment and operations for safe waste handling and downhole emplacement of test packages, while contributing to an evaluation of the overall safety and practicality of the DBD concept. The DBFT also includes drilling and downhole characterization investigations that are described elsewhere (see Section 1). Importantly, no radioactive waste will be used in the DBFT, nor will the DBFT site be used for disposal of any type of waste. The foremost performance objective for conduct of the DBFT is to demonstrate safe operations in all aspects of the test.

  15. Geophysical borehole logging in Lavia borehole - results and interpretation of sonic and tube wave measurements

    International Nuclear Information System (INIS)

    Andersson, P.; Stenberg, L.

    1985-02-01

    Swedish Nuclear Fuel and Waste Management Co, SKB has been contracted by Industrial Power Company LTD, TVO to perform geophysical logging in a borehole at Lavia in Western Finland. The logging has been conducted by Swedish Geological Co, SGAB in accordance with an agreement for cooperation with SKB. The depth of the borehole is 1001 m, diameter 56 mm and inclination 10-20 degrees to the vertical. The aim of the logging was to determine the various geophysical parameters in the borehole in order to interpret and understand the rock mass properties in the vicinity of the borehole. According to the contract the report covers the following main objectives: a technical description of the field work and the equipment used; a review of the theoretical base for the sonic and tube wave methods; an interpretation and presentation of the results obtained by sonic and tube wave mesurements. The evaluation of the sonic and tube wave measurements shows good correlation. On a qualitative basis there seems to be a correlation between tube wave generating points, the relative tube wave amplitudes and the hydraulic conductivity measurements performed as hydraulical tests between packers in the borehole. The low velocity anamalies in the sonic log are mainly caused by tectonic features like fractures and fracture zones but to some extent also by contacts between granite and diorite. The estimation of elastic properties of the rock mass from observation of tube wave velocity are in accordance with laboratory determinations made on core samples. (author)

  16. Core drilling of deep borehole OL-KR3B at Olkiluoto in Eurajoki 2005

    Energy Technology Data Exchange (ETDEWEB)

    Rautio, T. [Suomen Malmi Oy, Espoo (Finland)

    2005-10-15

    Posiva Oy submitted an application for the Decision in Principle to the Finnish Government in May 1999. A positive decision was made at the end of 2000 by the Government. The Finnish Parliament ratified the Decision in Principle on the final disposal facility for spent nuclear fuel at Olkiluoto, Eurajoki in May 2001. The decision makes it possible for Posiva to focus the confirming bedrock investigations at Olkiluoto, where in the next few years an underground rock characterisation facility, ONKALO, will be constructed. As a part of the investigations Suomen Malmi Oy (Smoy) core drilled 530.60 m deep borehole with a diameter of 75.7 mm at Olkiluoto in summer 2005. This borehole was aimed to get additional information of the quality of bedrock in the area, where a new shaft with a diameter of 3 m is planned to be located. The identification number of the borehole is OL-KR38. A set of monitoring measurements and samplings from the drilling and returning water was carried out during the drilling. Both the volume and the electric conductivity of the drilling water and the returning water were recorded. The drill rig was computer controlled and during drilling the computer recorded information about drilling parameters. The objective of these measurements was to obtain more information about bedrock and groundwater properties. Sodium fluorescein was used as a label agent in the drilling water. The volume of the used drilling water was about 473m{sup 3} and the measured volume of the returning water was about 38m{sup 3} in borehole OL-KR38. The deviation of the borehole was measured with the deviation measuring instruments EMS and Devitool Peewee. The results of the EMS measurements indicate that borehole OL-KR38 deviates 1.02 m south and 0.58 m west from the target point at the borehole depth of 525 m. Uniaxial compressive strength, Young's Modulus and Poisson's ratio were measured from the core samples. The average uniaxial compressive strength is about 106

  17. Core drilling of deep borehole OL-KR32 at Olkiluoto in Eurajoki 2004

    Energy Technology Data Exchange (ETDEWEB)

    Rautio, T. [Suomen Malmi Oy, Espoo (Finland)

    2005-01-15

    Posiva Oy submitted an application for the Decision in Principle to the Finnish Government in May 1999. A positive decision was made at the end of 2000 by the Government. The Finnish Parliament ratified the Decision in Principle on the final disposal facility for spent nuclear fuel at Olkiluoto, Eurajoki in May 2001. The decision makes it possible for Posiva to focus the confirming bedrock investigations at Olkiluoto, where in the next few years an underground rock characterisation facility, the ONKALO, will be constructed. As a part of the investigations Suomen Malmi Oy (Smoy) core drilled a 191.81 m deep borehole with a diameter of 75.7 mm at Olkiluoto in November 2004. This borehole was aimed to get additional information of the quality and the location of the fractured zones R20A and R20B and the fractured zones near rock surface noticed in investigation trench TK8. The identification number of the borehole is OL-KR32. A set of monitoring measurements and samplings from the drilling and returning water was carried out during the drilling. Both the volume and the electric conductivity of the drilling water and the returning water were recorded as well as the pressure of the drilling water. The objective of these measurements was to obtain more information about bedrock and groundwater properties. Sodium fluorescein was used as a label agent in the drilling water. The volume of the used drilling water was about 93 m{sup 3} and the measured volume of the returning water was about 6 m{sup 3} in borehole OL-KR32. The deviation of the borehole was measured with the deviation measuring instruments EMS and Maxibor. The results of the Maxibor measurements indicate that borehole OL-KR32 deviates 4.42 m right and 4.66 m up at the borehole depth of 189 m. Uniaxial compressive strength, Young's Modulus and Poisson's ratio were measured from the core samples. The average uniaxial compressive strength is about 130 MPa, the average Young's modulus is 47 GPa and

  18. Core drilling of deep borehole OL-KR39 at Olkiluoto in Eurajoki 2005

    Energy Technology Data Exchange (ETDEWEB)

    Niinimaeki, R. [Suomen Malmi Oy, Espoo (Finland)

    2005-11-15

    Posiva Oy submitted an application to the Finnish Government in May 1999 for the Decision in Principle to choose Olkiluoto in the municipality of Eurajoki as the site of the final disposal facility for spent nuclear fuel. A positive decision was made at the end of 2000 by the Government. The Finnish Parliament ratified the decision in May 2001. The decision makes it possible for Posiva to focus the confirming bedrock investigations at Olkiluoto, where in the next few years an underground rock characterisation facility, ONKALO, will be constructed. As a part of the investigations Suomen Malmi Oy (Smoy) core drilled 502.97 m and 45.11 m deep boreholes with a diameter of 75.7 mm at Olkiluoto in August- October 2005. The identification numbers of the boreholes are OL-KR39 and OL-KR39B, respectively. A set of monitoring measurements and samplings from the drilling and returning water was carried out during the drilling. Both the volume and the electric conductivity of the drilling water and the returning water were recorded. The drill rig was computer controlled and during drilling the computer recorded drilling parameters. The objective of all these measurements was to obtain more information about bedrock and groundwater properties. Sodium fluorescein was used as a label agent in the drilling water. The total volumes of the used drilling and flushing water were 415m{sup 3} and 25 m{sup 3} and the measured volumes of the returning water were 175 m{sup 3} and 7 m{sup 3} in boreholes OLKR39 and OL-KR39B, respectively. The deviation of the borehole was measured with the deviation measuring instruments EMS and Maxibor. Uniaxial compressive strength, Young's Modulus and Poisson' s ratio were measured from the core samples. The average uniaxial compressive strength is about 110 MPa, the average Young's Modulus is 49 GP a and the average Poisson' s ratio is 0.25. The main rock types are migmatitic mica gneiss and granite. Filled fracture is the most common

  19. Core drilling of deep borehole OL-KR34 at Olkiluoto in Eurajoki 2005

    Energy Technology Data Exchange (ETDEWEB)

    Rautio, T. [Suomen Malmi Oy, Espoo (Finland)

    2005-07-15

    Posiva Oy submitted an application for the Decision in Principle to the Finnish Government in May 1999. A positive decision was made at the end of 2000 by the Government. The Finnish Parliament ratified the Decision in Principle on the final disposal facility for spent nuclear fuel at Olkiluoto, Eurajoki in May 2001. The decision makes it possible for Posiva to focus the confirming bedrock investigations at Olkiluoto, where in the next few years an underground rock characterisation facility, ONKALO, will be constructed. As a part of the investigations Suomen Malmi Oy (Smoy) core drilled 100.07 m deep borehole with a diameter of 75.7 mm at Olkiluoto in April 2005. This borehole was aimed to get additional information of the quality of bedrock and the anomalous part of the bedrock and quality and the location of the fractured zones R19A and R19B. The identification number of the borehole is OL-KR34. A set of monitoring measurements and samplings from the drilling and returning water was carried out during the drilling. Both the volume and the electric conductivity of the drilling water and the returning water were recorded. The drill rig was computer controlled and during drilling the computer recorded information about drilling parameters. The objective of all measurements was to obtain more information about bedrock and groundwater properties. Sodium fluorescein was used as a label agent in the drilling water. The volume of the used drilling water was about 37m{sup 3} and the measured volume of the returning water was about 18m{sup 3} in borehole OL-KR34. The deviation of the borehole was measured with the deviation measuring instruments EMS and Maxibor. The results of the Maxibor measurements indicate that borehole OLKR34 deviates 0.84 m right and 0.15 m up at the borehole depth of 99 m. Uniaxial compressive strength, Young's Modulus and Poisson' s ratio were measured from the core samples. The average uniaxial compressive strength is about 142 MPa, the

  20. Core drilling of deep borehole OL-KR36 at Olkiluoto in Eurajoki 2005

    Energy Technology Data Exchange (ETDEWEB)

    Niinimaeki, R.; Rautio, T. [Suomen Malmi Oy, Espoo (Finland)

    2005-07-15

    Posiva Oy submitted an application for the Decision in Principle to the Finnish Government in May 1999. A positive decision was made at the end of 2000 by the Government. The Finnish Parliament ratified the Decision in Principle on the final disposal facility for spent nuclear fuel at Olkiluoto, Eurajoki in May 2001. The decision makes it possible for Posiva to focus the confirming bedrock investigations at Olkiluoto, where in the next few years an underground rock characterisation facility, ONKALO, will be constructed. As a part of the investigations Suomen Malmi Oy (Smoy) core drilled 205.17 m deep borehole with a diameter of 75.7 mm at Olkiluoto in May 2005. This borehole was aimed to get additional information of the quality of bedrock and the anomalous part of the bedrock and quality and the location of the fractured zones R19A and R19B. The identification number of the borehole is OL-KR36. A set of monitoring measurements and samplings from the drilling and returning water was carried out during the drilling. Both the volume and the electric conductivity of the drilling water and the returning water were recorded. The drill rig was computer controlled and during drilling the computer recorded information about drilling measurements. The objective of all these measurements was to obtain more information about bedrock and groundwater properties. Sodium fluorescein was used as a label agent in the drilling water. The volume of the used drilling water was about 117 m{sup 3} and the measured volume of the returning water was about 51m{sup 3} in borehole OL-KR36. The deviation of the borehole was measured with the deviation measuring instruments EMS and Maxibor. The results of the Maxibor measurements indicate that borehole OL-KR36 deviates 10.34 m left and 7.11 m up at the borehole depth of 204 m. Uniaxial compressive strength, Young's Modulus and Poisson' s ratio were measured from the core samples. The average uniaxial compressive strength is about 126

  1. Core drilling of deep borehole OL-KR35 at Olkiluoto in Eurajoki 2005

    Energy Technology Data Exchange (ETDEWEB)

    Rautio, T. [Suomen Malmi Oy, Espoo (Finland)

    2005-07-15

    Posiva Oy submitted an application for the Decision in Principle to the Finnish Government in May 1999. A positive decision was made at the end of 2000 by the Government. The Finnish Parliament ratified the Decision in Principle on the final disposal facility for spent nuclear fuel at Olkiluoto, Eurajoki in May 2001. The decision makes it possible for Posiva to focus the confirming bedrock investigations at Olkiluoto, where in the next few years an underground rock characterisation facility, ONKALO, will be constructed. As a part of the investigations Suomen Malmi Oy (Smoy) core drilled 100.87 m deep borehole with a diameter of 75.7 mm at Olkiluoto in May 2005. This borehole was aimed to get additional information of the quality of bedrock and the anomalous part of the bedrock and quality and the location of the fractured zones R19A and R19B. The identification number of the borehole is OL-KR35. A set of monitoring measurements and samplings from the drilling and returning water was carried out during the drilling. Both the volume and the electric conductivity of the drilling water and the returning water were recorded. The drill rig was computer controlled and during drilling the computer recorded information about drilling parameters. The objective of all measurements was to obtain more information about bedrock and groundwater properties. Sodium fluorescein was used as a label agent in the drilling water. The volume of the used drilling water was about 53 m{sup 3} and the measured volume of the returning water was about 25 m{sup 3} in borehole OL-KR35. The deviation of the borehole was measured with the deviation measuring instruments EMS and Maxibor. The results of the Maxibor measurements indicate that borehole OL-KR35 deviates 0.49 m right and 0.30 m up at the borehole depth of 99 m. Uniaxial compressive strength, Young's Modulus and Poisson' s ratio were measured from the core samples. The average uniaxial compressive strength is about 90 MPa, the

  2. Core drilling of deep borehole OL-KR39 at Olkiluoto in Eurajoki 2005

    International Nuclear Information System (INIS)

    Niinimaeki, R.

    2005-11-01

    Posiva Oy submitted an application to the Finnish Government in May 1999 for the Decision in Principle to choose Olkiluoto in the municipality of Eurajoki as the site of the final disposal facility for spent nuclear fuel. A positive decision was made at the end of 2000 by the Government. The Finnish Parliament ratified the decision in May 2001. The decision makes it possible for Posiva to focus the confirming bedrock investigations at Olkiluoto, where in the next few years an underground rock characterisation facility, ONKALO, will be constructed. As a part of the investigations Suomen Malmi Oy (Smoy) core drilled 502.97 m and 45.11 m deep boreholes with a diameter of 75.7 mm at Olkiluoto in August- October 2005. The identification numbers of the boreholes are OL-KR39 and OL-KR39B, respectively. A set of monitoring measurements and samplings from the drilling and returning water was carried out during the drilling. Both the volume and the electric conductivity of the drilling water and the returning water were recorded. The drill rig was computer controlled and during drilling the computer recorded drilling parameters. The objective of all these measurements was to obtain more information about bedrock and groundwater properties. Sodium fluorescein was used as a label agent in the drilling water. The total volumes of the used drilling and flushing water were 415m 3 and 25 m 3 and the measured volumes of the returning water were 175 m 3 and 7 m 3 in boreholes OLKR39 and OL-KR39B, respectively. The deviation of the borehole was measured with the deviation measuring instruments EMS and Maxibor. Uniaxial compressive strength, Young's Modulus and Poisson' s ratio were measured from the core samples. The average uniaxial compressive strength is about 110 MPa, the average Young's Modulus is 49 GP a and the average Poisson' s ratio is 0.25. The main rock types are migmatitic mica gneiss and granite. Filled fracture is the most common fracture type. The average fracture

  3. Core drilling of deep borehole OL-KR32 at Olkiluoto in Eurajoki 2004

    International Nuclear Information System (INIS)

    Rautio, T.

    2005-01-01

    Posiva Oy submitted an application for the Decision in Principle to the Finnish Government in May 1999. A positive decision was made at the end of 2000 by the Government. The Finnish Parliament ratified the Decision in Principle on the final disposal facility for spent nuclear fuel at Olkiluoto, Eurajoki in May 2001. The decision makes it possible for Posiva to focus the confirming bedrock investigations at Olkiluoto, where in the next few years an underground rock characterisation facility, the ONKALO, will be constructed. As a part of the investigations Suomen Malmi Oy (Smoy) core drilled a 191.81 m deep borehole with a diameter of 75.7 mm at Olkiluoto in November 2004. This borehole was aimed to get additional information of the quality and the location of the fractured zones R20A and R20B and the fractured zones near rock surface noticed in investigation trench TK8. The identification number of the borehole is OL-KR32. A set of monitoring measurements and samplings from the drilling and returning water was carried out during the drilling. Both the volume and the electric conductivity of the drilling water and the returning water were recorded as well as the pressure of the drilling water. The objective of these measurements was to obtain more information about bedrock and groundwater properties. Sodium fluorescein was used as a label agent in the drilling water. The volume of the used drilling water was about 93 m 3 and the measured volume of the returning water was about 6 m 3 in borehole OL-KR32. The deviation of the borehole was measured with the deviation measuring instruments EMS and Maxibor. The results of the Maxibor measurements indicate that borehole OL-KR32 deviates 4.42 m right and 4.66 m up at the borehole depth of 189 m. Uniaxial compressive strength, Young's Modulus and Poisson's ratio were measured from the core samples. The average uniaxial compressive strength is about 130 MPa, the average Young's modulus is 47 GPa and the average Poisson

  4. Self-monitoring of blood pressure in hypertension: A systematic review and individual patient data meta-analysis.

    Science.gov (United States)

    Tucker, Katherine L; Sheppard, James P; Stevens, Richard; Bosworth, Hayden B; Bove, Alfred; Bray, Emma P; Earle, Kenneth; George, Johnson; Godwin, Marshall; Green, Beverly B; Hebert, Paul; Hobbs, F D Richard; Kantola, Ilkka; Kerry, Sally M; Leiva, Alfonso; Magid, David J; Mant, Jonathan; Margolis, Karen L; McKinstry, Brian; McLaughlin, Mary Ann; Omboni, Stefano; Ogedegbe, Olugbenga; Parati, Gianfranco; Qamar, Nashat; Tabaei, Bahman P; Varis, Juha; Verberk, Willem J; Wakefield, Bonnie J; McManus, Richard J

    2017-09-01

    Self-monitoring of blood pressure (BP) appears to reduce BP in hypertension but important questions remain regarding effective implementation and which groups may benefit most. This individual patient data (IPD) meta-analysis was performed to better understand the effectiveness of BP self-monitoring to lower BP and control hypertension. Medline, Embase, and the Cochrane Library were searched for randomised trials comparing self-monitoring to no self-monitoring in hypertensive patients (June 2016). Two reviewers independently assessed articles for eligibility and the authors of eligible trials were approached requesting IPD. Of 2,846 articles in the initial search, 36 were eligible. IPD were provided from 25 trials, including 1 unpublished study. Data for the primary outcomes-change in mean clinic or ambulatory BP and proportion controlled below target at 12 months-were available from 15/19 possible studies (7,138/8,292 [86%] of randomised participants). Overall, self-monitoring was associated with reduced clinic systolic blood pressure (sBP) compared to usual care at 12 months (-3.2 mmHg, [95% CI -4.9, -1.6 mmHg]). However, this effect was strongly influenced by the intensity of co-intervention ranging from no effect with self-monitoring alone (-1.0 mmHg [-3.3, 1.2]), to a 6.1 mmHg (-9.0, -3.2) reduction when monitoring was combined with intensive support. Self-monitoring was most effective in those with fewer antihypertensive medications and higher baseline sBP up to 170 mmHg. No differences in efficacy were seen by sex or by most comorbidities. Ambulatory BP data at 12 months were available from 4 trials (1,478 patients), which assessed self-monitoring with little or no co-intervention. There was no association between self-monitoring and either lower clinic or ambulatory sBP in this group (clinic -0.2 mmHg [-2.2, 1.8]; ambulatory 1.1 mmHg [-0.3, 2.5]). Results for diastolic blood pressure (dBP) were similar. The main limitation of this work was that significant

  5. Self-monitoring of blood pressure in hypertension: A systematic review and individual patient data meta-analysis.

    Directory of Open Access Journals (Sweden)

    Katherine L Tucker

    2017-09-01

    Full Text Available Self-monitoring of blood pressure (BP appears to reduce BP in hypertension but important questions remain regarding effective implementation and which groups may benefit most. This individual patient data (IPD meta-analysis was performed to better understand the effectiveness of BP self-monitoring to lower BP and control hypertension.Medline, Embase, and the Cochrane Library were searched for randomised trials comparing self-monitoring to no self-monitoring in hypertensive patients (June 2016. Two reviewers independently assessed articles for eligibility and the authors of eligible trials were approached requesting IPD. Of 2,846 articles in the initial search, 36 were eligible. IPD were provided from 25 trials, including 1 unpublished study. Data for the primary outcomes-change in mean clinic or ambulatory BP and proportion controlled below target at 12 months-were available from 15/19 possible studies (7,138/8,292 [86%] of randomised participants. Overall, self-monitoring was associated with reduced clinic systolic blood pressure (sBP compared to usual care at 12 months (-3.2 mmHg, [95% CI -4.9, -1.6 mmHg]. However, this effect was strongly influenced by the intensity of co-intervention ranging from no effect with self-monitoring alone (-1.0 mmHg [-3.3, 1.2], to a 6.1 mmHg (-9.0, -3.2 reduction when monitoring was combined with intensive support. Self-monitoring was most effective in those with fewer antihypertensive medications and higher baseline sBP up to 170 mmHg. No differences in efficacy were seen by sex or by most comorbidities. Ambulatory BP data at 12 months were available from 4 trials (1,478 patients, which assessed self-monitoring with little or no co-intervention. There was no association between self-monitoring and either lower clinic or ambulatory sBP in this group (clinic -0.2 mmHg [-2.2, 1.8]; ambulatory 1.1 mmHg [-0.3, 2.5]. Results for diastolic blood pressure (dBP were similar. The main limitation of this work was that

  6. The problems of individual monitoring for internal exposure of monazite storage facility workers

    International Nuclear Information System (INIS)

    Ekidin, A.; Kirdin, I.; Yarmoshenko, I.; Zhukovsky, M.

    2006-01-01

    traditionally two situations of internal inhalation exposure by alpha emitting nuclides are considered in radiological protection: occupational exposure due to inhalation of plutonium aerosols; inhalation exposure by 222 Rn daughters in working places and in home. for these situations the problems of radioactive aerosols intake, nuclide dynamics in human body, internal dosimetry, nuclide excretion, monitoring of internal exposure have been investigated in details especially for plutonium inhalation exposure. The results of these studies are presented in details in ICRP Publications and UNSCEAR reports. However there is very specific case in which the special analysis of internal inhalation exposure is need. it is the working places with anomalous, extremely high concentration of thoron ( 220 Rn) daughters. The problems of internal radiation exposure of workers in such working place are the main topic of this publication. (authors)

  7. A panel of microsatellites to individually identify leopards and its application to leopard monitoring in human dominated landscapes

    Directory of Open Access Journals (Sweden)

    Selvaraj Velu

    2009-12-01

    Full Text Available Abstract Background Leopards are the most widely distributed of the large cats, ranging from Africa to the Russian Far East. Because of habitat fragmentation, high human population densities and the inherent adaptability of this species, they now occupy landscapes close to human settlements. As a result, they are the most common species involved in human wildlife conflict in India, necessitating their monitoring. However, their elusive nature makes such monitoring difficult. Recent advances in DNA methods along with non-invasive sampling techniques can be used to monitor populations and individuals across large landscapes including human dominated ones. In this paper, we describe a DNA-based method for leopard individual identification where we used fecal DNA samples to obtain genetic material. Further, we apply our methods to non-invasive samples collected in a human-dominated landscape to estimate the minimum number of leopards in this human-leopard conflict area in Western India. Results In this study, 25 of the 29 tested cross-specific microsatellite markers showed positive amplification in 37 wild-caught leopards. These loci revealed varied levels of polymorphism (four-12 alleles and heterozygosity (0.05-0.79. Combining data on amplification success (including non-invasive samples and locus specific polymorphisms, we showed that eight loci provide a sibling probability of identity of 0.0005, suggesting that this panel can be used to discriminate individuals in the wild. When this microsatellite panel was applied to fecal samples collected from a human-dominated landscape, we identified 7 individuals, with a sibling probability of identity of 0.001. Amplification success of field collected scats was up to 72%, and genotype error ranged from 0-7.4%. Conclusion Our results demonstrated that the selected panel of eight microsatellite loci can conclusively identify leopards from various kinds of biological samples. Our methods can be used to

  8. Recommendations of the AIRP-SEFP-SFPR working group individual radiological monitoring document-dosimetric data base

    International Nuclear Information System (INIS)

    Litido, M.; Busuoli, G.; Pelliccioni, M.; Iniiguez Saez, J.; Dollo, R.

    1996-01-01

    On the initiative of the chairmen of the three radiation protection societies (Italian, French, Spanish), it has been decided to extend the study carried out at TAORMINA (Sicily, Italy) joint conference on the harmonization of radiation protection practices. In order to formulate proposals on this topic, a working group was created at the end of 1993 made up of representatives of each society, with the objective of harmonizing the individual radiological monitoring documents and methods of recording and managing dosimetric information in data banks. (author)

  9. Accuracy of Continuous Glucose Monitoring Measurements in Normo-Glycemic Individuals

    DEFF Research Database (Denmark)

    Akintola, Abimbola A; Noordam, Raymond; Jansen, Steffy W

    2015-01-01

    a 24-hour period. Validity of CGM-derived individual glucose measurements, calculated measures of glycemia over daytime (09:00h-23:00h) and nighttime (23:00h-09:00h), and calculated measures of glycemic variability (e.g. 24h standard deviation [SD]) were assessed by Pearson correlation coefficients......, mean absolute relative difference (MARD) and paired t-tests. RESULTS: The median correlation coefficient between CGM and venous glucose measurements per participant was 0.68 (interquartile range: 0.40-0.78), and the MARD was 17.6% (SD = 17%). Compared with venous sampling, the calculated measure...

  10. Emotional Self-Regulation of Individuals with Autism Spectrum Disorders: Smartwatches for Monitoring and Interaction

    Directory of Open Access Journals (Sweden)

    Juan C. Torrado

    2017-06-01

    Full Text Available In this paper, we analyze the needs of individuals with Autism Spectrum Disorders (ASD to have a pervasive, feasible and non-stigmatizing form of assistance in their emotional self-regulation, in order to ease certain behavioral issues that undermine their mental health throughout their life. We argue the potential of recent widespread wearables, and more specifically smartwatches, to achieve this goal. Then, a smartwatch system that implements a wide range of self-regulation strategies and infers outburst patterns from physiological signals and movement is presented, along with an authoring tool for smartphones that is to be used by caregivers or family members to create and edit these strategies, in an adaptive way. We conducted an intensive experiment with two individuals with ASD who showed varied, representative behavioral responses to their emotional dysregulation. Both users were able to employ effective, customized emotional self-regulation strategies by means of the system, recovering from the majority of mild stress episodes and temper tantrums experienced in the nine days of experiment in their classroom.

  11. Excavation damage and organic growth in a 1.2m diameter borehole

    International Nuclear Information System (INIS)

    Everitt, R.A.; Gann, P.; Brown, D.A.; Boychuk, D.M.

    1994-01-01

    A 1.24m diameter borehole was drilled 5m into the floor of a typical drill-and-blast tunnel in unfractured granite, at AECL's Underground Research Laboratory. Three generations of excavation damage, characteristic of what may be encountered in boreholes excavated for in-hole emplacement of used fuel wastes was observed. These include: (1) damage related to the initial excavation of the room, (2) damage caused by the drilling of the borehole itself, and (3) damage due to subsequent stress-induced spalling of the borehole walls. A biofilm containing a variety of microorganisms has developed where seepage issues from the concrete-granite interface. The biota were introduced from surface water used for mining and drilling. Their growth has been stimulated by residues from blasting and drilling, which have concentrated iron and silicon by passive sorption and energy metabolism. Ferrous iron has been oxidized and precipitated as ferrihydrite/hematite to give an orange/brown colouration on the biofilm interface black. These observations, significant to the understanding and monitoring of excavation damage, highlight the importance of thorough, in situ, multi-disciplinary characterization for vault design

  12. Field-scale permeability and temperature of volcanic crust from borehole data: Campi Flegrei, southern Italy

    Science.gov (United States)

    Carlino, Stefano; Piochi, Monica; Tramelli, Anna; Mormone, Angela; Montanaro, Cristian; Scheu, Bettina; Klaus, Mayer

    2018-05-01

    We report combined measurements of petrophysical and geophysical parameters for a 501-m deep borehole located on the eastern side of the active Campi Flegrei caldera (Southern Italy), namely (i) in situ permeability by pumping tests, (ii) laboratory-determined permeability of the drill core, and (iii) thermal gradients by distributed fiber optic and thermocouple sensors. The borehole was drilled during the Campi Flegrei Deep Drilling Project (in the framework of the International Continental Scientific Drilling Program) and gives information on the least explored caldera sector down to pre-caldera deposits. The results allow comparative assessment of permeability obtained from both borehole (at depth between 422 a 501 m) and laboratory tests (on a core sampled at the same depth) for permeability values of 10-13 m2 (borehole test) and 10-15 m2 (laboratory test) confirm the scale-dependency of permeability at this site. Additional geochemical and petrophysical determinations (porosity, density, chemistry, mineralogy and texture), together with gas flow measurements, corroborate the hypothesis that discrepancies in the permeability values are likely related to in-situ fracturing. The continuous distributed temperature profile points to a thermal gradient of about 200 °C km-1. Our findings (i) indicate that scale-dependency of permeability has to be carefully considered in modelling of the hydrothermal system at Campi Flegrei, and (ii) improve the understanding of caldera dynamics for monitoring and mitigation of this very high volcanic risk area.

  13. Evidos: optimisation of individual monitoring in mixed neutron/photon fields at workplaces of the nuclear fuel cycle

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Reginatto, M.; Schuhmacher, H.; Lacoste, V.; Muller, M.; Boschung, M.; Fiechtner, A.; Coeck, M.; Vanhavere, F.; Curzio, G.; D'errico, F.; Kyllonen, J.E.; Lindborg, L.; Molinos, C.; Tanner, R.; Derdau, D.; Lahaye, Th.

    2005-01-01

    Within its 5. Framework Programme, the EC is funding the project EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'). The aim of this project is the optimisation of individual monitoring at workplaces of the nuclear fuel cycle with special regard to neutrons. Various dosemeters for mixed field application - passive and new electronic devices - are tested in selected workplace fields in nuclear installations in Europe. The fields are characterised using a series of spectrometers that provide the energy distribution of neutron fluence (Bonner spheres) and newly developed devices that provide the energy and directional distribution of the neutron fluence. Results from the first measurement campaign, carried out in simulated workplace fields (IRSN, Cadarache. France), and those of a second measurement campaign, carried out at workplaces at a boiling water reactor and at a storage cask with used fuel elements (Kernkraftwerk Kriimmel, Germany), are described. (authors)

  14. Protecting coastal abstraction boreholes from seawater intrusion using self-potential data

    Science.gov (United States)

    Graham, Malcolm; Butler, Adrian; MacAllister, Donald John; Vinogradov, Jan; Ijioma, Amadi; Jackson, Matthew

    2016-04-01

    We investigate whether the presence and transport of seawater can influence self-potentials (SPs) measured within coastal groundwater boreholes, with a view to using SP monitoring as part of an early warning system for saline intrusion. SP data were collected over a period of 18 months from a coastal groundwater borehole in the fractured Chalk of England. Spectral analysis of the results shows semi-diurnal fluctuations that are several orders of magnitude higher than those observed from monitoring of the Chalk more than 60 km inland, indicating a strong influence from oceanic tides. Hydrodynamic and geoelectric modelling of the coastal aquifer suggests that observed pressure changes (giving rise to the streaming potential) are not sufficient to explain the magnitude of the observed SP fluctuations. Simulation of the exclusion-diffusion potential, produced by changes in concentration across the saline front, is required to match the SP data from the borehole, despite the front being located some distance away. In late summer of 2013 and 2014, seawater intrusion occurred in the coastal monitoring borehole. When referenced to the shallowest borehole electrode, there was a characteristic increase in SP within the array, several days before any measurable increase in salinity. The size of this precursor increased steadily with depth, typically reaching values close to 0.3 mV in the deepest electrode. Numerical modelling suggests that the exclusion-diffusion potential can explain the magnitude of the precursor, but that the polarity of the change in SP cannot be replicated assuming a homogeneous aquifer. Small-scale models of idealised Chalk blocks were used to simulate the effects of discrete fractures on the distribution of SP. Initial results suggest that comparatively large reductions in voltage can develop in the matrix ahead of the front, in conjunction with a reduced or absent precursor in the vicinity of a fracture. Geophysical logging indicates the presence of a

  15. Individual monitoring with official electronic dosemeters in Germany - concepts and reality

    International Nuclear Information System (INIS)

    Martini, E.; Wahl, W.; Huebner, S.; Freynhagen, D.; Staemmler, M.

    2005-01-01

    Full text: Active (electronic) personal dosemeters (APD) are radiometers, which are equipped as active or passive dosimeters. They can directly indicate a dose rate and/or the dose integrated during a certain period (direct-indicating, active electronic personal dosemeters mentioned) or only over a separate reader (direct-selectable, passive electronic personal dosemeters mentioned). A concept is presented for the use of passive or active electronic personal dosemeters in Germany as official dosemeters, e.g. in hospitals. The concept features a net-based approach for secure data communication between readers for passive and active electronic personal dosemeters und the official personal dosimetry monitoring service(s), taking the German policies (StrISchV und RoeV in hospitals) into account. The net-based solution includes a processor controlled interface via TCP/IP connected to the dosimetry reader(s), und reader interfaces, an official interim data bank and all the necessary equipment such as PC, Raid-configuration, USV support, network connection and further details. Investigations have been started to achieve highest-level data manipulation security, data completeness und data correctness. (author)

  16. Conceptual Design and Requirements for Characterization and Field Test Boreholes: Deep Borehole Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, Kristopher L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brady, Patrick Vane [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); MacKinnon, Robert J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Heath, Jason E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Herrick, Courtney G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jensen, Richard P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rigali, Mark J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hadgu, Teklu [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sevougian, S. David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Birkholzer, Jens [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Freifeld, Barry M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Daley, Tom [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-09-24

    Deep Borehole Disposal (DBD) of high-level radioactive wastes has been considered an option for geological isolation for many years (Hess et al. 1957). Recent advances in drilling technology have decreased costs and increased reliability for large-diameter (i.e., ≥50 cm [19.7”]) boreholes to depths of several kilometers (Beswick 2008; Beswick et al. 2014). These advances have therefore also increased the feasibility of the DBD concept (Brady et al. 2009; Cornwall 2015), and the current field test, introduced herein, is a demonstration of the DBD concept and these advances.

  17. Conversion coefficients for individual monitoring calculated with integrated tiger series, ITS3, Monte Carlo code

    International Nuclear Information System (INIS)

    Devine, R.T.; Hsu, Hsiao-Hua

    1994-01-01

    The current basis for conversion coefficients for calibrating individual photon dosimeters in terms of dose equivalents is found in the series of papers by Grosswent. In his calculation the collision kerma inside the phantom is determined by calculation of the energy fluence at the point of interest and the use of the mass energy absorption coefficient. This approximates the local absorbed dose. Other Monte Carlo methods can be sued to provide calculations of the conversion coefficients. Rogers has calculated fluence-to-dose equivalent conversion factors with the Electron-Gamma Shower Version 3, EGS3, Monte Carlo program and produced results similar to Grosswent's calculations. This paper will report on calculations using the Integrated TIGER Series Version 3, ITS3, code to calculate the conversion coefficients in ICRU Tissue and in PMMA. A complete description of the input parameters to the program is given and comparison to previous results is included

  18. Individual neutron monitoring in workplaces with mixed neutron/proton radiation

    International Nuclear Information System (INIS)

    Bolognese-Milsztajn, T.; Bartlett, D.; Boschung, M.; Coeck, M.; Curzio, G.; D'Errico, F.; Fiechtner, A.; Giusti, V.; Gressier, V.; Kylloenen, J.; Lacoste, V.; Lindborg, L.; Luszik-Bhadra, M.; Molinos, C.; Pelcot, G.; Reginatto, M.; Schuhmacher, H.; Tanner, R.; Vanhavere, F.; Derdau, D.

    2004-01-01

    EVIDOS ('evaluation of individual dosimetry in mixed neutron and photon radiation fields') is an European Commission (EC)-sponsored project that aims at a significant improvement of radiation protection dosimetry in mixed neutron/photon fields via spectrometric and dosimetric investigations in representative workplaces of the nuclear industry. In particular, new spectrometry methods are developed that provide the energy and direction distribution of the neutron fluence from which the reference dosimetric quantities are derived and compared to the readings of dosemeters. The final results of the project will be a comprehensive set of spectrometric and dosimetric data for the workplaces and an analysis of the performance of dosemeters, including novel electronic dosemeters. This paper gives an overview of the project and focuses on the results from measurements performed in calibration fields with broad energy distributions (simulated workplace fields) and on the first results from workplaces in the nuclear industry, inside a boiling water reactor and around a spent fuel transport cask. (authors)

  19. Effects of the deviation characteristics of nuclear waste emplacement boreholes on borehole liner stresses; Yucca Mountain Project

    Energy Technology Data Exchange (ETDEWEB)

    Glowka, D.A.

    1990-09-01

    This report investigates the effects of borehole deviation on the useability of lined boreholes for the disposal of high-level nuclear waste at the proposed Yucca Mountain Repository in Nevada. Items that lead to constraints on borehole deviation include excessive stresses that could cause liner failure and possible binding of a waste container inside the liner during waste emplacement and retrieval operations. Liner stress models are developed for two general borehole configurations, one for boreholes drilled with a steerable bit and one for boreholes drilled with a non-steerable bit. Procedures are developed for calculating liner stresses that arise both during insertion of the liner into a borehole and during the thermal expansion process that follows waste emplacement. The effects of borehole curvature on the ability of the waste container to pass freely inside the liner without binding are also examined. Based on the results, specifications on borehole deviation allowances are developed for specific vertical and horizontal borehole configurations of current interest. 11 refs., 22 figs., 4 tabs.

  20. Utilization of test boreholes in prospecting and mining operations

    International Nuclear Information System (INIS)

    Sierak, J.P.

    1987-01-01

    Test boreholes are of fundamental importance for mining and prospecting operations. The drilling techniques are suited to the geological conditions and to the nature of the information desired. At Cogema, non-coring test boreholes, mainly drilled by a rotary percussive method, represent over 90% of the footage drilled; they achieve impressive performances at a cost which is by far less than that of coring test boreholes. The geological exploitation of these test boreholes is effected by a combined investigation of well logging and of cuttings. These investigations lead to an assessment for certain substances like uranium or coal or they mark the limits for favourable zones which alone will form the object of coring boreholes. In mining operations, boreholes indicate the definition for workable panels; they ensure at less cost the distribution of fluids, the forwarding of stowing material and the mine ventilation [fr

  1. Diffracted X-ray tracking for monitoring intramolecular motion in individual protein molecules using broad band X-ray

    Energy Technology Data Exchange (ETDEWEB)

    Ichiyanagi, Kouhei; Sasaki, Yuji C. [Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 609 Kiban Building 5-1-5 Kashiwanoha, Kahiwashi, Chiba 277-8561 (Japan); Japan Science and Technology Agency, CREST, CREST, Sasaki-Team, 609 Kiban Building, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan); Sekiguchi, Hiroshi; Hoshino, Masato; Kajiwara, Kentaro; Senba, Yasunori; Ohashi, Haruhiko; Ohta, Noboru [Japan Synchrotron Radiation Research Institute, SPring-8, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan); Hoshisashi, Kentaro; Jae-won, Chang; Tokue, Maki; Matsushita, Yufuku [Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 609 Kiban Building 5-1-5 Kashiwanoha, Kahiwashi, Chiba 277-8561 (Japan); Nishijima, Masaki; Inoue, Yoshihisa [Department of Applied Chemistry and Office for University-Industry Collaboration, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan); Yagi, Naoto [Japan Science and Technology Agency, CREST, CREST, Sasaki-Team, 609 Kiban Building, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan); Japan Synchrotron Radiation Research Institute, SPring-8, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

    2013-10-15

    Diffracted X-ray tracking (DXT) enables the tilting and twisting motions of single protein molecules to be monitored with micro- to milliradian resolution using a highly brilliant X-ray source with a wide energy bandwidth. We have developed a technique to monitor single molecules using gold nanocrystals attached to individual protein molecules using the BL28B2 beamline at SPring-8. In this paper we present the installation of a single toroidal X-ray mirror at BL28B2 to focus X-rays in an energy range of 10–20 keV (△E/E = 82% for an X-ray with a wide energy bandwidth). With this beamline we tracked diffraction spots from gold nanocrystals over a wide angle range than that using quasi-monochromatic X-rays. Application of the wide angle DXT technique to biological systems enabled us to observe the on-site motions of single protein molecules that have been functionalized in vivo. We further extend the capability of DXT by observing the fractional tilting and twisting motions of inner proteins under various conditions. As a proof of this methodology and to determine instrumental performance the intramolecular motions of a human serum albumin complex with 2-anthracenecarboxylic acid was investigated using the BL28B2 beamline. The random tilting and twisting intramolecular motions are shown to be directly linked to the movement of individual protein molecules in the buffer solution.

  2. External individual monitoring: experiments and simulations using Monte Carlo Method; Monitoracao individual externa: experimentos e simulacoes com o metodo de Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Carla da Costa

    2005-07-01

    In this work, we have evaluated the possibility of applying the Monte Carlo simulation technique in photon dosimetry of external individual monitoring. The GEANT4 toolkit was employed to simulate experiments with radiation monitors containing TLD-100 and CaF{sub 2}:NaCl thermoluminescent detectors. As a first step, X ray spectra were generated impinging electrons on a tungsten target. Then, the produced photon beam was filtered in a beryllium window and additional filters to obtain the radiation with desired qualities. This procedure, used to simulate radiation fields produced by a X ray tube, was validated by comparing characteristics such as half value layer, which was also experimentally measured, mean photon energy and the spectral resolution of simulated spectra with that of reference spectra established by international standards. In the construction of thermoluminescent dosimeter, two approaches for improvements have. been introduced. The first one was the inclusion of 6% of air in the composition of the CaF{sub 2}:NaCl detector due to the difference between measured and calculated values of its density. Also, comparison between simulated and experimental results showed that the self-attenuation of emitted light in the readout process of the fluorite dosimeter must be taken into account. Then, in the second approach, the light attenuation coefficient of CaF{sub 2}:NaCl compound estimated by simulation to be 2,20(25) mm{sup -1} was introduced. Conversion coefficients C{sub p} from air kerma to personal dose equivalent were calculated using a slab water phantom with polymethyl-metacrilate (PMMA) walls, for reference narrow and wide X ray spectrum series [ISO 4037-1], and also for the wide spectra implanted and used in routine at Laboratorio de Dosimetria. Simulations of backscattered radiations by PMMA slab water phantom and slab phantom of ICRU tissue-equivalent material produced very similar results. Therefore, the PMMA slab water phantom that can be easily

  3. Core drilling of deep borehole OL-KR33 at Olkiluoto in Eurajoki 2004

    Energy Technology Data Exchange (ETDEWEB)

    Rautio, T. [Suomen Malmi Oy, Espoo (Finland)

    2005-01-15

    Posiva Oy submitted an application for the Decision in Principle to the Finnish Government in May 1999. A positive decision was made at the end of 2000 by the Government. The Finnish Parliament ratified the Decision in Principle on the final disposal facility for spent nuclear fuel at Olkiluoto, Eurajoki in May 2001. The decision makes it possible for Posiva to focus the confirming bedrock investigations at Olkiluoto, where in the next few years an underground rock characterisation facility, the ONKALO, will be constructed. As a part of the investigations Suomen Malmi Oy (Smoy) core drilled 311.02 m and 45.53 m deep boreholes with a diameter of 75.7 mm at Olkiluoto in November-December 2004. These boreholes were aimed to get additional information of the quality of bedrock and the quality and the location of the fractured zones R2, RH9 and R72. The identification numbers of the boreholes are OL-KR33 and OL-KR33B, respectively. A set of monitoring measurements and samplings from the drilling and returning water was carried out during the drilling. Both the volume and the electric conductivity of the drilling water and the returning water were recorded as well as the pressure of the drilling water. The objective of these measurements was to obtain more information about bedrock and groundwater properties. Sodium fluorescein was used as a label agent in the drilling water. The volumes of the used drilling water were about 195m{sup 3} and 14m{sup 3} and the measured volumes of the returning water were about 100 m{sup 3} and 9 m{sup 3} in boreholes OL-KR33 and OL-KR33B, respectively. The deviations of the boreholes were measured with the deviation measuring instruments EMS and Maxibor. The results of the Maxibor measurements indicate that borehole OL-KR33 deviates 15.97 m right and 31.04 m up at the borehole depth of 309 m. Uniaxial compressive strength, Young's Modulus and Poisson's ratio were measured from the core samples. The average uniaxial compressive

  4. Aspects of ICRP 60 and ICRU 47 relevant to individual monitoring of external exposure

    International Nuclear Information System (INIS)

    Dietze, G.; Menzel, H.G.

    1994-01-01

    Exposure limits recommended by the ICRP and used in regulations are expressed in risk related quantities such as effective dose or effective dose equivalent. Operational quantities such as ambient dose equivalent or personal dose equivalent are defined in phantoms and are designed to give reasonable estimates of exposure limiting quantities. The readings of individual dosemeters are calibrated in terms of operational quantities. The international commissions involved in the definition of risk related quantities (ICRP) and operational quantities (ICRU) have introduced various new definitions and modifications to previous quantities used in their respective publications ICRP 60 and ICRU 39, ICRU 47. The consequences of these alterations for the relationships between quantities within the hierarchy have to be examined and the new quantitative relationships (conversion coefficients) between basic physical radiation quantities such as particle fluence or air kerma and the new quantities have to be evaluated. In 1992, the ICRP and ICRU charged a joint task group with addressing these tasks with a view to revising ICRP Publication 51. This paper presents an outline for the subject of the report to be prepared by the task group. An introduction to the new phantom-based quantities is given and conceptional differences between the newly introduced and the previous quantities are discussed. (author)

  5. A strategy to seal exploratory boreholes in unsaturated tuff

    International Nuclear Information System (INIS)

    Fernandez, J.A.; Case, J.B.; Givens, C.A.; Carney, B.C.

    1994-04-01

    This report presents a strategy for sealing exploratory boreholes associated with the Yucca Mountain Site Characterization Project. Over 500 existing and proposed boreholes have been considered in the development of this strategy, ranging from shallow (penetrating into alluvium only) to deep (penetrating into the groundwater table). Among the comprehensive list of recommendations are the following: Those boreholes within the potential repository boundary and penetrating through the potential repository horizon are the most significant boreholes from a performance standpoint and should be sealed. Shallow boreholes are comparatively insignificant and require only nominal sealing. The primary areas in which to place seals are away from high-temperature zones at a distance from the potential repository horizon in the Paintbrush nonwelded tuff and the upper portion of the Topopah Spring Member and in the tuffaceous beds of the Calico Hills Unit. Seals should be placed prior to waste emplacement. Performance goals for borehole seals both above and below the potential repository are proposed. Detailed construction information on the boreholes that could be used for future design specifications is provided along with a description of the environmental setting, i.e., the geology, hydrology, and the in situ and thermal stress states. A borehole classification scheme based on the condition of the borehole wall in different tuffaceous units is also proposed. In addition, calculations are presented to assess the significance of the boreholes acting as preferential pathways for the release of radionuclides. Design calculations are presented to answer the concerns of when, where, and how to seal. As part of the strategy development, available technologies to seal exploratory boreholes (including casing removal, borehole wall reconditioning, and seal emplacement) are reviewed

  6. Development of an electronic monitor for the determination of individual radon and thoron exposure

    Energy Technology Data Exchange (ETDEWEB)

    Irlinger, Josef

    2015-06-11

    The carcinogenic effect of the radio isotope {sup 222}Rn of the noble gas radon and its progeny, as well as its residential distribution, are well studied. In contrast, the knowledge about the effects and average dwelling concentration levels of its radio isotope {sup 220}Rn (thoron) is still limited. Generally, this isotope has been assumed to be a negligible contributor to the effective annual dose. However, only recently it has been pointed out in several international studies, that the dose due to thoron exceeds the one from {sup 222}Rn under certain conditions. Additionally, radon monitors may show a considerable sensitivity towards thoron which was also not accounted for in general. Therefore a reliable, inexpensive exposimeter, which allows to distinguish between decays of either radon and thoron, is required to conduct further studies. The scope of this thesis was to develop an electronic radon/thoron exposimeter which features small size, low weight and minimal power consumption. The design is based on the diffusion chamber principle and employs state-of-the-art alpha particle spectroscopy to measure activity concentrations. The device was optimized via inlet layout and filter selection for high thoron diffusion. Calibration measurements showed a similar sensitivity of the monitor towards radon and thoron, with a calibration factor of cf{sup {sub 2}{sub 2}{sub 2Rn}} = 16.2 ± 0.9 Bq m{sup -3}/cph and cf{sup {sub 2}{sub 2}{sub 0Rn}} = 14.4 ± 0.8 Bq m{sup -3}/cph, respectively. Thus, the radon sensitivity of the device was enhanced by a factor two compared to a previous prototype. The evaluation method developed in this work, in accordance with ISO 11665 standards, was validated by intercomparison measurements. The detection limits for radon and thoron were determined to be C{sup {sub 2}{sub 2}{sub 2Rn}} = 44.0 Bq m{sup -3} and C{sup {sub 2}{sub 2}{sub 0Rn}} = 40.0 Bq m{sup -3}, respectively, in case of a low radon environment, a one-hour measurement

  7. Development of an electronic monitor for the determination of individual radon and thoron exposure

    International Nuclear Information System (INIS)

    Irlinger, Josef

    2015-01-01

    The carcinogenic effect of the radio isotope 222 Rn of the noble gas radon and its progeny, as well as its residential distribution, are well studied. In contrast, the knowledge about the effects and average dwelling concentration levels of its radio isotope 220 Rn (thoron) is still limited. Generally, this isotope has been assumed to be a negligible contributor to the effective annual dose. However, only recently it has been pointed out in several international studies, that the dose due to thoron exceeds the one from 222 Rn under certain conditions. Additionally, radon monitors may show a considerable sensitivity towards thoron which was also not accounted for in general. Therefore a reliable, inexpensive exposimeter, which allows to distinguish between decays of either radon and thoron, is required to conduct further studies. The scope of this thesis was to develop an electronic radon/thoron exposimeter which features small size, low weight and minimal power consumption. The design is based on the diffusion chamber principle and employs state-of-the-art alpha particle spectroscopy to measure activity concentrations. The device was optimized via inlet layout and filter selection for high thoron diffusion. Calibration measurements showed a similar sensitivity of the monitor towards radon and thoron, with a calibration factor of cf 222 Rn = 16.2 ± 0.9 Bq m -3 /cph and cf 220 Rn = 14.4 ± 0.8 Bq m -3 /cph, respectively. Thus, the radon sensitivity of the device was enhanced by a factor two compared to a previous prototype. The evaluation method developed in this work, in accordance with ISO 11665 standards, was validated by intercomparison measurements. The detection limits for radon and thoron were determined to be C 2 22 Rn = 44.0 Bq m -3 and C 2 20 Rn = 40.0 Bq m -3 , respectively, in case of a low radon environment, a one-hour measurement interval, and a background count rate of zero. In contrast, in mixed radon/thoron concentrations where the 212 Po peak must

  8. Cerebral Blood Flow Autoregulation in Sepsis for the Intensivist: Why Its Monitoring May Be the Future of Individualized Care.

    Science.gov (United States)

    Goodson, Carrie M; Rosenblatt, Kathryn; Rivera-Lara, Lucia; Nyquist, Paul; Hogue, Charles W

    2018-02-01

    Cerebral blood flow (CBF) autoregulation maintains consistent blood flow across a range of blood pressures (BPs). Sepsis is a common cause of systemic hypotension and cerebral dysfunction. Guidelines for BP management in sepsis are based on historical concepts of CBF autoregulation that have now evolved with the availability of more precise technology for its measurement. In this article, we provide a narrative review of methods of monitoring CBF autoregulation, the cerebral effects of sepsis, and the current knowledge of CBF autoregulation in sepsis. Current guidelines for BP management in sepsis are based on a goal of maintaining mean arterial pressure (MAP) above the lower limit of CBF autoregulation. Bedside tools are now available to monitor CBF autoregulation continuously. These data reveal that individual BP goals determined from CBF autoregulation monitoring are more variable than previously expected. In patients undergoing cardiac surgery with cardiopulmonary bypass, for example, the lower limit of autoregulation varied between a MAP of 40 to 90 mm Hg. Studies of CBF autoregulation in sepsis suggest patients frequently manifest impaired CBF autoregulation, possibly a result of BP below the lower limit of autoregulation, particularly in early sepsis or with sepsis-associated encephalopathy. This suggests that the present consensus guidelines for BP management in sepsis may expose some patients to both cerebral hypoperfusion and cerebral hyperperfusion, potentially resulting in damage to brain parenchyma. The future use of novel techniques to study and clinically monitor CBF autoregulation could provide insight into the cerebral pathophysiology of sepsis and offer more precise treatments that may improve functional and cognitive outcomes for survivors of sepsis.

  9. Nuclear borehole probes - theory and experiments

    International Nuclear Information System (INIS)

    Joergensen, J.L.; Korsbech, U.; Gynther Nielsen, K.; Oelgaard, P.L.

    1985-06-01

    The report gives a summary of the theoretical and expeimental work on borehole probes that has been performed since 1971 at The Department of Electrophysics, The Technical University of Denmark. The first part of the report concerns the use of a spectral natural gamma-ray probe (SNG-probe), which is used for measurements of the spectral distribution of the gamma-rays of the geological strata around a borehole. In general the spectrum is divided into three parts - the gamma-rays from potassium-40, from thorium-232 and daughters, and from uranium-238 and daughters. A set of curves showing the intensities of the gamm-radiation from K, Th, and U versus depth is called a SNG-log. If proper calibrated, the SNG-log gives the concentration of Th, U, and K in the formation surrounding the borehole. Initially the basis for an interpretation of SNG-logs is discussed. Then follows a description og some SNG-problems designed and built by The Department of Electrophysics, and a discussion of the calibration of SNG-probes. Some examples of SNG-logs are presented, and some general comments on the use of SNG-logs are given. The second part of the report concerns mainly the development of theoretical models for neutron-neutron probes, gamma-gamma probes, and pulsed-neutron probes. The purpose of this work has been to examine how well the models correlate with measured results and - where reasonable agreement is found - to use the models in studies of the factors that affect the probe responses in interpretation of experimental results and in probe design. (author)

  10. Quality assurance and quality control programme in use at the individual monitoring service of ITN-DPRSN

    Energy Technology Data Exchange (ETDEWEB)

    Alves, J.G.; Novais, I.; Rangel, S.; Flores, E. [Instituto Tecnologico e Nuclear, Dept. de Proteccao Radiologica e Seguranca Nuclear Estrada Nacional, Sacavem (Portugal)

    2006-07-01

    The Individual Monitoring Service (I.M.S.) of the Departamento de Proteccao Radiologica e Seguranca Nuclear (D.P.R.S.N.) at the Instituto Tecnologico e Nuclear (I.T.N.) in Portugal operates a thermoluminescence dosimetry system to monitor approximately 3,000 workers for external radiation exposure on a monthly basis. The workers come from nearly 230 facilities in the medical, research and conventional industry fields of activity and almost 85% of the people monitored in 2005 are from medical facilities. The TLD system in use is based on two Harshaw 6600 automatic readers and on the Harshaw 8814 T.L. card and holder containing two detector elements of LiF:Mg,Ti (TLD-100) for the evaluation of Hp(10) and Hp(0.07). All the workers are monitored on a monthly basis using whole body dosemeters. The I.M.S. has implemented a Quality Assurance and Quality Control (Q.A./Q.C.) programme that covers all the aspects of monitoring, from the monitoring request of a customer to the final issue of a dose report. The main aspects of the Q.A./Q.C. programme implemented at the I.M.S. will be presented in this paper using fluxograms and schemes. Several issues will be addressed, e.g., administrative procedures, technical procedures, dealing with complaints, training of staff, etc. The relationship of the I.M.S. with external entities like the customer, the regulatory authority, the central dose registry, the calibration facility, suppliers, maintenance providers, etc. will be mentioned on the administrative procedures described as well as on the technical procedures where applicable. The main technical procedures will be presented in this paper and references will be made to a TLD Quality Control database internally developed and designed for the storage of important Q.C. parameters like the element correction coefficients, reader calibration factors, electronic quality control data generated on a daily basis, and the study of their evolution with time. (author)

  11. Quality assurance and quality control programme in use at the individual monitoring service of ITN-DPRSN

    International Nuclear Information System (INIS)

    Alves, J.G.; Novais, I.; Rangel, S.; Flores, E.

    2006-01-01

    The Individual Monitoring Service (I.M.S.) of the Departamento de Proteccao Radiologica e Seguranca Nuclear (D.P.R.S.N.) at the Instituto Tecnologico e Nuclear (I.T.N.) in Portugal operates a thermoluminescence dosimetry system to monitor approximately 3,000 workers for external radiation exposure on a monthly basis. The workers come from nearly 230 facilities in the medical, research and conventional industry fields of activity and almost 85% of the people monitored in 2005 are from medical facilities. The TLD system in use is based on two Harshaw 6600 automatic readers and on the Harshaw 8814 T.L. card and holder containing two detector elements of LiF:Mg,Ti (TLD-100) for the evaluation of Hp(10) and Hp(0.07). All the workers are monitored on a monthly basis using whole body dosemeters. The I.M.S. has implemented a Quality Assurance and Quality Control (Q.A./Q.C.) programme that covers all the aspects of monitoring, from the monitoring request of a customer to the final issue of a dose report. The main aspects of the Q.A./Q.C. programme implemented at the I.M.S. will be presented in this paper using fluxograms and schemes. Several issues will be addressed, e.g., administrative procedures, technical procedures, dealing with complaints, training of staff, etc. The relationship of the I.M.S. with external entities like the customer, the regulatory authority, the central dose registry, the calibration facility, suppliers, maintenance providers, etc. will be mentioned on the administrative procedures described as well as on the technical procedures where applicable. The main technical procedures will be presented in this paper and references will be made to a TLD Quality Control database internally developed and designed for the storage of important Q.C. parameters like the element correction coefficients, reader calibration factors, electronic quality control data generated on a daily basis, and the study of their evolution with time. (author)

  12. Data of groundwater from boreholes, river water and precipitation for the Horonobe Underground Research Laboratory project. 2011-2010

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yuki; Yamamoto, Yoichi; Nanjyo, Isao; Murakami, Hiroaki; Yokota, Hideharu; Yamazaki, Masanori; Iwatsuki, Teruki [Japan Atomic Energy Agency, Geological Isolation Research and Development Directorate, Horonobe, Hokkaido (Japan); Kunimaru, Takanori [Japan Atomic Energy Agency, Geological Isolation Research and Development Directorate, Mizunami, Gifu (Japan); Oyama, Takahiro [Central Research Inst. of Electric Power Industry, Tokyo (Japan)

    2012-02-15

    In the Horonobe Underground Research Laboratory (URL) Project, groundwater from boreholes, river water and precipitation have been analyzed for the environmental monitoring since the fiscal year 2001. This report shows the data set of water chemistry since the fiscal year 2001 to the fiscal year 2010. (author)

  13. Data of groundwater from boreholes, river water and precipitation for the Horonobe Underground Research Laboratory project. 2011-2010

    International Nuclear Information System (INIS)

    Amano, Yuki; Yamamoto, Yoichi; Nanjyo, Isao; Murakami, Hiroaki; Yokota, Hideharu; Yamazaki, Masanori; Iwatsuki, Teruki; Kunimaru, Takanori; Oyama, Takahiro

    2012-02-01

    In the Horonobe Underground Research Laboratory (URL) Project, groundwater from boreholes, river water and precipitation have been analyzed for the environmental monitoring since the fiscal year 2001. This report shows the data set of water chemistry since the fiscal year 2001 to the fiscal year 2010. (author)

  14. Mathematical characterization of the milk progesterone profile as a leg up to individualized monitoring of reproduction status in dairy cows.

    Science.gov (United States)

    Adriaens, Ines; Huybrechts, Tjebbe; Geerinckx, Katleen; Daems, Devin; Lammertyn, Jeroen; De Ketelaere, Bart; Saeys, Wouter; Aernouts, Ben

    2017-11-01

    Reproductive performance is an important factor affecting the profitability of dairy farms. Optimal fertility results are often confined by the time-consuming nature of classical heat detection, the fact that high-producing dairy cows show estrous symptoms shorter and less clearly, and the occurrence of ovarian problems. Today's commercially available solutions for automatic estrus detection include monitoring of activity, temperature and progesterone. The latter has the advantage that, besides estrus, it also allows to detect pregnancy and ovarian problems. Due to the large variation in progesterone profiles, even between cycles within the same cow, the use of general thresholds is suboptimal. To this end, an intelligent and individual interpretation of the progesterone measurements is required. Therefore, an alternative solution is proposed, which takes individual and complete cycle progesterone profiles into account for reproduction monitoring. In this way, profile characteristics can be translated into specific attentions for the farmers, based on individual rather than general guidelines. To enable the use of the profile and cycle characteristics, an appropriate model to describe the milk progesterone profile was developed. The proposed model describes the basal adrenal progesterone production and the growing and regressing cyclic corpus luteum. To identify the most appropriate way to describe the increasing and decreasing part of each cycle, three mathematical candidate functions were evaluated on the increasing and decreasing parts of the progesterone cycle separately: the Hill function, the logistic growth curve and the Gompertz growth curve. These functions differ in the way they describe the sigmoidal shape of each profile. The increasing and decreasing parts of the P4 cycles were described best by the model based on respectively the Hill and Gompertz function. Combining these two functions, a full mathematical model to characterize the progesterone cycle

  15. Repository and deep borehole disposition of plutonium

    International Nuclear Information System (INIS)

    Halsey, W.G.

    1996-02-01

    Control and disposition of excess weapons plutonium is a growing issue as both the US and Russia retire a large number of nuclear weapons> A variety of options are under consideration to ultimately dispose of this material. Permanent disposition includes tow broad categories: direct Pu disposal where the material is considered waste and disposed of, and Pu utilization, where the potential energy content of the material is exploited via fissioning. The primary alternative to a high-level radioactive waste repository for the ultimate disposal of plutonium is development of a custom geologic facility. A variety of geologic facility types have been considered, but the concept currently being assessed is the deep borehole

  16. Bench top and portable mineral analysers, borehole core analysers and in situ borehole logging

    International Nuclear Information System (INIS)

    Howarth, W.J.; Watt, J.S.

    1982-01-01

    Bench top and portable mineral analysers are usually based on balanced filter techniques using scintillation detectors or on low resolution proportional detectors. The application of radioisotope x-ray techniques to in situ borehole logging is increasing, and is particularly suited for logging for tin and higher atomic number elements

  17. Core drilling of deep borehole OL-KR37 at Olkiluoto in Eurajoki 2005

    Energy Technology Data Exchange (ETDEWEB)

    Niinimaeki, R. [Suomen Malmi Oy, Espoo (Finland)

    2005-11-15

    Posiva Oy submitted an application to the Finnish Government in May 1999 for the Decision in Principle to choose Olkiluoto in the municipality of Eurajoki as the site of the final disposal facility for spent nuclear fuel. A positive decision was made at the end of 2000 by the Government. The Finnish Parliament ratified the decision in May 2001. The decision makes it possible for Posiva to focus the confirming bedrock investigations at Olkiluoto, where in the next few years an underground rock characterisation facility, ONKALO, will be constructed. As a part of the investigations Suomen Malmi Oy (Smoy) core drilled 350.00 m and 45.10 m deep boreholes with a diameter of 75.7 mm at Olkiluoto in June- August 2005. The identification numbers of the boreholes are OL-KR37 and OL-KR37B, respectively. A set of monitoring measurements and samplings from the drilling and returning water was carried out during the drilling. Both the volume and the electric conductivity of the drilling water and the returning water were recorded. The drill rig was computer controlled and during drilling the computer recorded information about drilling parameters. The objective of all these measurements was to obtain more information about bedrock and groundwater properties. Sodium fluorescein was used as a label agent in the drilling water. The total volumes of the used drilling and flushing water were 273 m{sup 3} and 21m{sup 3} and the measured volumes of the returning water were 221m{sup 3} and 16m{sup 3} in boreholes OL-KR37 and OL-KR37B, respectively. The deviation of the borehole was measured with the deviation measuring instruments EMS and Maxibor. Uniaxial compressive strength, Young's Modulus and Poisson' s ratio were measured from the core samples. The average uniaxial compressive strength is about 106 MPa, the average Young's modulus is 40 GPa and the average Poisson's ratio is 0.20. The main rock types are migmatitic mica gneiss, granite and tonalite. Filled

  18. Imaging CO2 reservoirs using muons borehole detectors

    Science.gov (United States)

    Bonneville, A.; Bonal, N.; Lintereur, A.; Mellors, R. J.; Paulsson, B. N. P.; Rowe, C. A.; Varner, G. S.; Kouzes, R.; Flygare, J.; Mostafanezhad, I.; Yamaoka, J. A. K.; Guardincerri, E.; Chapline, G.

    2016-12-01

    Monitoring of the post-injection fate of CO2 in subsurface reservoirs is of utmost importance. Generally, monitoring options are active methods, such as 4D seismic reflection or pressure measurements in monitoring wells. We present a method of 4D density tomography of subsurface CO2 reservoirs using cosmic-ray muon detectors deployed in a borehole. Although muon flux rapidly decreases with depth, preliminary analyses indicate that the muon technique is sufficiently sensitive to effectively map density variations caused by fluid displacement at depths consistent with proposed CO2reservoirs. The intensity of the muon flux is, to first order, inversely proportional to the density times the path length, with resolution increasing with measurement time. The primary technical challenge preventing deployment of this technology in subsurface locations is the lack of miniaturized muon-tracking detectors both capable of fitting in standard boreholes and that will be able to resist the harsh underground conditions (temperature, pressure, corrosion) for long periods of time. Such a detector with these capabilities has been developed through a collaboration supported by the U.S. Department of Energy. A prototype has been tested in underground laboratories during 2016. In particular, we will present results from a series of tests performed in a tunnel comparing efficiencies, and angular and position resolution to measurements collected at the same locations by large instruments developed by Los Alamos and Sandia National Laboratories. We will also present the results of simulations of muon detection for various CO2 reservoir situations and muon detector configurations. Finally, to improve imaging of 3D subsurface structures, a combination of seismic data, gravity data, and muons can be used. Because seismic waves, gravity anomalies, and muons are all sensitive to density, the combination of two or three of these measurements promises to be a powerful way to improve spatial

  19. Circular induction accelerator for borehole logging

    International Nuclear Information System (INIS)

    Chen, F.K.; Bertozzi, W.; Corris, G.W.; Diamond, W.; Doucet, J.A.; Schweitzer, J.S.

    1992-01-01

    This patent describes a downhole logging sonde adapted to be moved through a borehole, a source of gamma rays in the sonde for irradiating earth formations traversed by the borehole, one or more gamma ray detectors for detecting gamma rays scattered back to the sonde from the irradiated earth formations, and means for transmitting signals representative of the detected gamma rays to the earth's surface for processing. This patent describes improvement in the gamma ray source comprises a magnetic induction particle accelerator, including: a magnetic circuit having a field magnet, generally circular opposed pole pieces, and a core magnet metal ions from the group consisting of Mn, Zn and Ni; an excitation circuit including a field coil surrounding the field magnet and the core magnet and a core coil surrounding the central axially leg of the core magnet; an annular acceleration chamber interposed between the pole pieces; means for applying time-varying acceleration voltage pulses across the primary excitation circuit; means for injecting charged particles into orbit within the acceleration chamber; means for compressing the particle orbits to trap particles within generally circular orbits within the acceleration chamber; means for generating a particle accelerating magnetic flux in the magnetic circuit; and means for ejecting charged particles from the generally circular orbits and into contact with a target to produce gamma ray photons

  20. Second ILAW Site Borehole Characterization Plan

    International Nuclear Information System (INIS)

    Reidel, S.P.

    2000-01-01

    The US Department of Energy's Hanford Site has the most diverse and largest amounts of radioactive tank waste in the US. High-level radioactive waste has been stored at Hanford since 1944. Approximately 209,000 m 3 (54 Mgal) of waste are currently stored in 177 tanks. Vitrification and onsite disposal of low-activity tank waste (LAW) are embodied in the strategy described in the Tri-Party Agreement. The tank waste is to be retrieved, separated into low- and high-level fractions, and then immobilized. The low-activity vitrified waste will be disposed of in the 200 East Area of the Hanford Site. This report is a plan to drill and characterize the second borehole for the Performance Assessment. The first characterization borehole was drilled in 1998. The plan describes data collection activities for determining physical and chemical properties of the vadose zone and saturated zone on the northeast side of the proposed disposal site. These data will then be used in the 2005 Performance Assessment

  1. Borehole locations on seven interior salt domes

    International Nuclear Information System (INIS)

    Simcox, A.C.; Wampler, S.L.

    1982-08-01

    This report is designed as an inventory of all wells known to have been drilled within a five-mile radius of each of seven salt domes within the Interior Salt Basin in east Texas, northern Louisiana and Mississippi. There are 72 boreholes that entered salt above an elevation of -3000 feet mean sea level. For these, details of location, drilling dates, depth of casing and cement, elevation of top of caprock and salt, etc., are given on tables in the appendix. Of the seven domes, Oakwood has the largest number of boreholes, thirty-eight (including two sidetracked wells) that enter the salt stock above -3000 feet mean sea level; another dome in northeast Texas, Keechi, has eight; in northern Louisiana, Rayburn's has four and Vacherie has five; in southern Mississippi, Cypress Creek has seven, Lampton has one, and Richton has nine. In addition, all wells known outside the supra-domal area, but within a five-mile radius of the center of the 7 domes are separately catalogued

  2. Bhtv looks right down the borehole

    Energy Technology Data Exchange (ETDEWEB)

    1969-04-01

    A borehole televiewer uses acoustic pulses to produce a camera-like picture of downhole conditions. A block diagram shows the borehole televiewer logging system. The diameter of the tool is 3-3/8 in., but slimmer tools can be built. The nominal logging speed is 15 ft per min. Vertical fractures will show on the log as double vertical lines, horizontal fractures as single horizontal lines, and dipping fractures as curves that are roughly symmetrical. The orientation of the minimum of the curve is the dip direction of the fracture. The original idea was to find a tool to give guidance in fracturing jobs, and so far the tool has been primarily used for that purpose. It will also be a tremendous help for geologists and engineers on wildcate wells who have to make the agonizing decision to complete or abandon. It will show fracture porosity that no other currently available tool will show. It also will be a very useful supplement for the dipmeter. It can accurately locate vugs and washouts, and show changes in porosity and lithology. Mobil Oil is now using the tool as a standard log on all its wildcat wells.

  3. Regulatory issues for deep borehole plutonium disposition

    International Nuclear Information System (INIS)

    Halsey, W.G.

    1995-03-01

    As a result of recent changes throughout the world, a substantial inventory of excess separated plutonium is expected to result from dismantlement of US nuclear weapons. The safe and secure management and eventual disposition of this plutonium, and of a similar inventory in Russia, is a high priority. A variety of options (both interim and permanent) are under consideration to manage this material. The permanent solutions can be categorized into two broad groups: direct disposal and utilization. The deep borehole disposition concept involves placing excess plutonium deep into old stable rock formations with little free water present. Issues of concern include the regulatory, statutory and policy status of such a facility, the availability of sites with desirable characteristics and the technologies required for drilling deep holes, characterizing them, emplacing excess plutonium and sealing the holes. This white paper discusses the regulatory issues. Regulatory issues concerning construction, operation and decommissioning of the surface facility do not appear to be controversial, with existing regulations providing adequate coverage. It is in the areas of siting, licensing and long term environmental protection that current regulations may be inappropriate. This is because many current regulations are by intent or by default specific to waste forms, facilities or missions significantly different from deep borehole disposition of excess weapons usable fissile material. It is expected that custom regulations can be evolved in the context of this mission

  4. Borehole geophysics in nuclear power plant siting

    International Nuclear Information System (INIS)

    Crosby, J.W.; Scott, J.D.

    1979-01-01

    Miniaturized borehole geophysical equipment designed for use in ground-water investigations can be adapted to investigations of nuclear power plant sites. This equipment has proved to be of value in preliminary and comprehensive studies of interior basins where thick sequences of Quaternary clastic sediment, occasionally with associated volcanic rocks, pose problems of stratigraphic correlation. The unconsolidated nature of the deposits generally requires that exploratory holes be cased, which ordinarily restricts the borehole geophysical studies to the radiation functions--natural gamma, gamma-gamma, neutron-gamma, and neutron-epithermal neutron logs. Although a single log response may be dominant in a given area, correlations derive from consideration of all log responses as a composite group. Because major correlations usually are based upon subtle differences in the physical properties of the penetrated sediment, high-resolution logging procedures are employed with some sacrifice of the quantitative perameters important to petroleum technology. All geophysical field data are recorded as hard copy and as digital information on punched paper tape

  5. Borehole geophysics in nuclear power plant siting

    International Nuclear Information System (INIS)

    Crosby, J.W.; Scott, J.D.

    1979-01-01

    Miniaturized borehole geophysical equipment designed for use in ground-water investigations can be adapted to investigations of nuclear power plant sites. This equipment has proved to be of value in preliminary and comprehensive studies of interior basins where thick sequences of Quaternary clastic sediment, occasionally with associated volcanic rocks, pose problems of stratigraphic correlation. The unconsolidated nature of the deposits generally requires that exploratory holes be cased, which ordinarily restricts the borehole geophysical studies to the radiation functions--natural gamma, gamma-gamma, neutron-gamma, and neutron-epithermal neutron logs. Although a single log response may be dominant in a given area, correlations derive from consideration of all log responses as a composite group. Because major correlations usually are based upon subtle differences in the physical properties of the penetrated sediment, high-resolution logging procedures are employed with some sacrifice of the quantitative parameters important to petroleum technology. All geophysical field data are recorded as hard copy and as digital information on punched paper tape. Digital data are subsequently computer processed and plotted to scales that enhance the stratigraphic data being correlated. Retention of the data in analog format permits rapid review, whereas computer plotting allows playback and detailed examination of log sections and sequences that may be attenuated on hard copy because of the logarithmic nature of the response to the physical property being examined

  6. Field assessment of the use of borehole pressure transients to measure the permeability of fractured rock masses

    International Nuclear Information System (INIS)

    Forster, C.B.; Gale, J.E.

    1981-06-01

    A field experiment to evaluate the transient pressure pulse technique as a method of determining the in-situ hydraulic conductivity of low permeability fractured rock was made. The experiment attempted to define: the radius of influence of a pressure pulse-test in fractured rock and the correlation between pressure-pulse tests and steady-state flow tests performed in five boreholes drilled in fractured granite. Twenty-five test intervals, 2 to 3 m in length, were isolated in the boreholes, using air-inflated packers. During pressure pulse and steady-state tests, pressures were monitored in both the test and observation cavities. Rock-mass conductivities were calculated from steady-state test results and were found to range from less than 10 - 11 to 10 - 7 cm/sec. However, there was no consistent correlation between the steady-state conductivity and the pressure pulse decay characteristics of individual intervals. These conflicting test results can be attributed to the following factors: differences in volumes of rock affected by the test techniques; effects of equipment configuration and compliance; and complexity of the fracture network. Although the steady-state flow tests indicate that hydraulic connections exist between most of the test cavities, no pressure responses were noted in the observation cavities (located at least 0.3 m from the test cavities) during the pulse tests. This does not mean, however, that the pressure-pulse radius of influence is <0.3 m, because the observation cavities were too large (about 7 liters). The lack of correlation between steady-state conductivities and the corresponding pressure pulse decay times does not permit use of existing single-fracture type curves to analyze pulse tests performed in multiple-fracture intervals. Subsequent work should focus on the detailed interpretation of field results with particular reference to the effects of the fracture system at the test site

  7. Personal monitoring of 218Po and 214Po radionuclide deposition onto individuals under normal environmental exposure conditions

    International Nuclear Information System (INIS)

    Eatough, J.P.; Worley, A.; Moss, G.R.

    1999-01-01

    Personal dosemeters have been utilized to monitor the deposition of the radon decay products 218 Po and 214 Po onto individuals under normal environmental exposure conditions. Each detector consists of TASTRAK alpha-sensitive plastic incorporated into an ordinary working wristwatch. Subsequent analysis provides energy discrimination of the detected alpha-particle decays, and allows events from the individual radon decay products 218 Po and 214 Po, attached to the detector surface, to be uniquely identified. Assuming similar deposition onto skin and detector surfaces, the activity per unit area of deposited radionuclides can be determined for exposed skin. Forty-one personal dosemeters were issued to volunteers selected through the hospital medical physics departments at Reading, Northampton, Exeter and Plymouth. Each volunteer was also issued with a personal radon dosemeter to determine their individual radon exposure. The volunteers wore the two dosemeters simultaneously and continuously for a period of around one month. Correlations were observed between the radon exposure of the individual and the activity per unit area of 218 Po and 214 Po on the detector surface. From these correlations it can be estimated that at the UK average radon exposure of 20 Bq m -3 , the number of decays/cm 2 /year on continuously exposed skin surface is between 3500 and 28 000 for 218 Po, and between 7000 and 21 000 for 214 Po. These results can be combined with theoretical modelling of the dose distribution in the skin to yield the alpha-particle radiation dose to any identified target cells. (author)

  8. Assessment of the results of the 1998 Intercomparison of Individual Monitoring Systems under IAEA Model Project RLA/9/030

    International Nuclear Information System (INIS)

    Da Silva, Teogenes

    1999-01-01

    In this report the results of an intercomparison program within the framework of the IAEA model project RLA/9/030 are presented. This is the first phase of the study the main purpose was to establish a mechanism to identify and improve the current situation of each country as far as the performance of each individual monitoring system is concerned. This phase as was coordinated by Brazil through the Centro de Desenvolvimento da Tecnologia Nuclear that verified the performance of the participant laboratories. The following countries were invited to participate in the 1998 intercomparison: Bolivia, Costa Rica, Guatemala, Nicaragua, Panama, Jamaica and Paraguay. The performance of the laboratories was evaluated for dose assessment in terms of photon dose equivalent Hx

  9. Individual rights over public good? The future of anthropometric monitoring of school children in the fight against obesity.

    Science.gov (United States)

    Stubbs, Joanne M; Achat, Helen M

    2009-02-02

    Available evidence indicates that rates of childhood overweight and obesity have been increasing over the past two decades, but inconsistencies between study methods moderate the strength of this evidence. Concomitant health problems and associated costs make it imperative that primary prevention initiatives are introduced to combat the obesity epidemic. Fundamental to informed action is anthropometric monitoring, which if properly implemented will identify changes over time in specific populations to inform policies, practices and services aimed at prevention and treatment. Sample representativeness is essential for valid trend and prevalence data, but efforts to obtain population-based anthropometric data from school children with the required written parental consent have been thwarted by low participation rates. Notable improvements in participation rates when utilising opt-out consent, in which participation is assumed unless otherwise indicated, are evident from local as well as international studies. Opt-out consent can facilitate anthropometric monitoring, delivering a more informed, best-value-for-money response to the obesity epidemic. Health and education ethics committees need to acknowledge the benefits of opt-out consent for "low-risk" anthropometric measurement, which ultimately upholds the individual's rights.

  10. Individual monitoring and its quality assurance using thermoluminescent CaSO[sub 4]:Dy Teflon tape dosemeters in India

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Popli, K.L.; Varadharajan, G.; Kher, R.K.; Venkataraman, G. (Bhabha Atomic Research Centre, Bombay (India). Div. of Radiological Protection)

    1994-01-01

    CaSO[sub 4]:Dy Teflon thermoluminscence dosemeters have been fabricated indigenously in continuous tape form. TL response of the tape dosemeters to [beta] and [gamma] radiations has been studied as a function of the dosemeter thickness to arrive at its optimum value. A single 80 mg.cm[sup -2] thick tape dosemeter (51 mm x 17 mm) along with a mica strip replaces the earlier use of three 200 mg.cm[sup -2] thick disc dosemeters for routine individual monitoring. The tape cards have been in field use for two and half years. The performance characteristics of the cards under laboratory and field conditions are discussed. Dose computation algorithms have been developed to give whole-body dose (mGy) and skin dose (mGy)for photons and [beta] radiation respectively from the TL outputs of three dosimetric elements under 1000 mg.cm[sup -2] Cu + Al composite filter, 180 mg.cm[sup -2] Perspex and an open region in a cardholder. Results of the Quality Assurance Programme, covering various TL monitoring stations in India, are also presented. Based on ANSI criteria, only one outlier was observed over the past seven years. (Author).

  11. Evaluation of personal dose equivalent 'HP(d)' in a external individual monitoring system for X and gamma radiation

    International Nuclear Information System (INIS)

    Santoro, C.; Antonio Filho, J.; Santos, M.A.P.

    2007-01-01

    The good of individual monitoring for external radiation is the assessment of occupational exposure from X and γ radiations in order to assure that the radiological conditions of the workplace are acceptable, safe and satisfactory. The evaluation of radiations doses for workers must not exceed dose limits specified for workers, according to national regulatory agencies. Nowadays, there are two external monitoring systems in use, both based on ICRU definitions. In the conventional system, the workers doses are evaluated in terms of Hx. The personal dosimeter is worn over chest surface and it is calibrated in function of air kerma. In the new system, the workers doses are evaluated in terms of HP(d) and the personal dosimeter is calibrated in function of phantom doses. The aim of this paper is to adapt an external dosimetry laboratory (based on photographic dosimetry) to evaluate the personal dosimeters in terms of HP(d). In this way, a simple methodology, based on linear programming, was utilized. In this adaptation, calibration curves were obtained for radiation qualities (W and N series) described by International Organization for Standardization (ISO 4037-1, 1995). These calibration curves offer a better accuracy on dose determinations and energy below 140 keV, improving the quality of service rendered the society. (author)

  12. Phase correction of electromagnetic coupling effects in cross-borehole EIT measurements

    International Nuclear Information System (INIS)

    Zhao, Y; Zimmermann, E; Wolters, B; Van Waasen, S; Huisman, J A; Treichel, A; Kemna, A

    2015-01-01

    Borehole EIT measurements in a broad frequency range (mHz to kHz) are used to study subsurface geophysical properties. However, accurate measurements have long been difficult because the required long electric cables introduce undesired inductive and capacitive coupling effects. Recently, it has been shown that such effects can successfully be corrected in the case of single-borehole measurements. The aim of this paper is to extend the previously developed correction procedure for inductive coupling during EIT measurements in a single borehole to cross-borehole EIT measurements with multiple borehole electrode chains. In order to accelerate and simplify the previously developed correction procedure for inductive coupling, a pole–pole matrix of mutual inductances is defined. This consists of the inductances of each individual chain obtained from calibration measurements and the inductances between two chains calculated from the known cable positions using numerical modelling. The new correction procedure is successfully verified with measurements in a water-filled pool under controlled conditions where the errors introduced by capacitive coupling were well-defined and could be estimated by FEM forward modelling. In addition, EIT field measurements demonstrate that the correction methods increase the phase accuracy considerably. Overall, the phase accuracy of cross-hole EIT measurements after correction of inductive and capacitive coupling is improved to better than 1 mrad up to a frequency of 1 kHz, which substantially improves our ability to characterize the frequency-dependent complex electrical resistivity of weakly polarizable soils and sediments in situ. (paper)

  13. Geomechanical Considerations for the Deep Borehole Field Test

    Science.gov (United States)

    Park, B. Y.

    2015-12-01

    Deep borehole disposal of high-level radioactive waste is under consideration as a potential alternative to shallower mined repositories. The disposal concept consists of drilling a borehole into crystalline basement rocks to a depth of 5 km, emplacement of canisters containing solid waste in the lower 2 km, and plugging and sealing the upper 3 km of the borehole. Crystalline rocks such as granites are particularly attractive for borehole emplacement because of their low permeability and porosity at depth, and high mechanical strength to resist borehole deformation. In addition, high overburden pressures contribute to sealing of some of the fractures that provide transport pathways. We present geomechanical considerations during construction (e.g., borehole breakouts, disturbed rock zone development, and creep closure), relevant to both the smaller-diameter characterization borehole (8.5") and the larger-diameter field test borehole (17"). Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  14. Comparative study of coliform contamination of public boreholes ...

    African Journals Online (AJOL)

    This study was carried out to determine the coliform contamination of public boreholes and pipe borne water supplies within Bosso town. Twenty (20) water samples comprising of 10 each of borehole and pipe borne samples were aseptically collected from Bosso Town and analyzed using membrane filtration technique.

  15. Elastic waves along a cylindrical borehole in a poroelastic medium ...

    Indian Academy of Sciences (India)

    In the oil industry, acoustic borehole logging is commonly practiced. A borehole is drilled in a potential hydro-carbon reservoir and then probed with an acoustic ...... The non-dimensional phase velocity c/Vmin, Vmin = min(V1,V2,V3,V4) is computed at different values of non-dimensional wavenumber ka varying from 0 to 85.

  16. Performance of MarSite Multi parameter Borehole Instrumentation

    Science.gov (United States)

    Guralp, Cansun; Tunc, Suleyman; Ozel, Oguz; Meral Ozel, Nurcan; Necmioglu, Ocal

    2017-04-01

    In this paper we present two year results obtained from the integrated multiparameter borehole system at Marsite. The very broad band (VBB) system have been operating since installation in November 2014; one year in a water filled borehole and one year in a dry Borehole. from January 2016. The real time data has been available to the community. The two Borehole environments are compared showing the superior performance of dry borehole environ- ment compared to water filled for a very broad band (VBB) seismometer. The practical considerations applied in both borehole installations are compared and the best borehole practical installation techniques are presented and discussed. The data is also compared with a surface 120 second broad band sensor and the seismic arrays with in MarSite region. The very long term performance, (one year data in a dry hole) of the VBB Borehole seismometer and the Dilatometer will be presented The high frequency performance of the VBB seismometer which extends to 150 Hz and the dilatometer are compared characterizing the results from the dilatometer.

  17. 30 CFR 75.388 - Boreholes in advance of mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Boreholes in advance of mining. 75.388 Section... of mining. (a) Boreholes shall be drilled in each advancing working place when the working place... cannot be examined, and before mining continues, a certified person shall, if possible, determine— (1...

  18. Occurrence of a Severe Acute Livestock Poisoning by Borehole ...

    African Journals Online (AJOL)

    This article reports on an outbreak of acute livestock poisoning by borehole water that occurred at Kargi in Marsabit District, Kenya in 2000. The borehole had been out of use for 3 years and after its rehabilitation, 7,000 animals died within a day after drinking the water. The most affected were shoats, cattle, camels and dogs ...

  19. Borehole induction logging for the Dynamic Underground Stripping Project LLNL gasoline spill site

    International Nuclear Information System (INIS)

    Boyd, S.; Newmark, R.; Wilt, M.

    1994-01-01

    Borehole induction logs were acquired for the purpose of characterizing subsurface physical properties and monitoring steam clean up activities at the Lawrence Livermore National Laboratory. This work was part of the Dynamic Underground Stripping Project's demonstrated clean up of a gasoline spin. The site is composed of unconsolidated days, sands and gravels which contain gasoline both above and below the water table. Induction logs were used to characterize lithology, to provide ''ground truth'' resistivity values for electrical resistance tomography (ERT), and to monitor the movement of an underground steam plume used to heat the soil and drive volatile organic compounds (VOCs) to the extraction wells

  20. Neutron activation for logging the distribution of gold in bore-hole cores

    International Nuclear Information System (INIS)

    Rahmanian, H.; Watterson, J.I.W.

    1992-01-01

    A new method for the non-destructive determination of gold in bore-hole cores has been developed using instrumental neutron activation analysis with a 252 Cf source. The procedure obtains the distribution and concentration of gold along the longitudinal axis of the core i.e. a log of the gold concentration. The accuracy of the method is comparable to fire assay at a level of 2 ppm and has a detection limit of 1 ppm under the conditions used. The assay of the gold is carried out by employing a novel variation of the conventional comparator method using gold wires as both standard and flux monitor. A method is described for logging gold in bore-hole cores using neutron activation with a 160 μg 252 Cf neutron source. The method has a limit of detection of about 1 ppm under the described conditions. (author)

  1. Borehole Logging for Uranium by Gamma-Ray Spectrometry

    DEFF Research Database (Denmark)

    Løvborg, Leif; Nyegaard, P.; Christiansen, E. M.

    1980-01-01

    The resources in a large syngenetic deposit of low-grade uranium (U) ore with thorium at Kvanefjeld, South Greenland, were evaluated by spectrometric gamma-ray logging of 23 boreholes, 46 mm in diameter and 200 m deep. The borehole probe's detector contained 22 cm3 of sodium-iodide, and the photo......The resources in a large syngenetic deposit of low-grade uranium (U) ore with thorium at Kvanefjeld, South Greenland, were evaluated by spectrometric gamma-ray logging of 23 boreholes, 46 mm in diameter and 200 m deep. The borehole probe's detector contained 22 cm3 of sodium...... of the spectrometer system were determined by calculating the average number of U and thorium (Th) counts per meter of borehole and comparing these with the U-Th concentrations in 1-m sections of analyzed drill core. The sensitivity and the background count rate in the uranium window varied appreciably from one hole...

  2. The assessment of the geophysical investigations of boreholes

    International Nuclear Information System (INIS)

    Brotzen, O.; Duran, O.; Magnusson, K.-Aa.

    1980-02-01

    Four geophysical investigations and a televiewer inspection of boreholes have been evaluated in connection with the examinations at Finnsjoen, Karlshamn, Kraakemaala, Stripa and Studsvik. A cooperative assessment of the systems for the measurement of boreholes by Lawrence Berkeley Laboratories and the Geological Survey of Sweden has been made at Stripa. The following methods should be selected for future measurements: determination of the resistivity and temperature of the fluid in the borehole, determination of the resistivity and temperature of the fluid in the borehole, determination of the self-potential, resistivity and resistance of the rock as well as the measurement of sonar waves, the diameter of the borehole and the very low frequency effects. (G.B.)

  3. The borehole disposal of spent sources (BOSS)

    International Nuclear Information System (INIS)

    Heard, R.G.

    2002-01-01

    During the International Atomic Energy Agency (IAEA) Regional Training Course on 'The Management of Low-Level Radioactive Waste from Hospitals and Other Nuclear Applications' hosted by the Atomic Energy Corporation of SA Ltd. (AEC), now NECSA, during July/August 1995, the African delegates reviewed their national radioactive waste programmes. Among the issues raised, which are common to most African countries, were the lack of adequate storage facilities, lack of disposal solutions and a lack of equipment to implement widely used disposal concepts to dispose of their spent sources. As a result of this meeting, a Technical Co-operation (TC) project was launched to look at the technical feasibility and economic viability of such a concept. Phase I and II of the project have been completed and the results can be seen in three reports produced by NECSA. The Safety Assessment methodology used in the evaluation of the concept was that developed during the ISAM programme and detailed in Van Blerk's PhD thesis. This methodology is specifically developed for shallow land repositories, but was used in this case as the borehole need not be more than 100m deep and could fit into the definition of a shallow land disposal system. The studies found that the BOSS concept would be suitable for implementation in African countries as the borehole has a large capacity for sources and it is possible that an entire country's disused sources can be placed in a single borehole. The costs are a lot lower than for a shallow land trench, and the concept was evaluated using radium (226) sources as the most limiting inventory. The conclusion of the initial safety assessment was that the BOSS concept is robust, and provides a viable alternative for the disposal of radium needles. The concept is expected to provide good assurance of safety at real sites. The extension of the safety assessment to other types of spent sources is expected to be relatively straightforward. Disposal of radium needles

  4. Numerical Borehole Breakdown Investigations using XFEM

    Science.gov (United States)

    Beckhuis, Sven; Leonhart, Dirk; Meschke, Günther

    2016-04-01

    During pressurization of a wellbore a typical downhole pressure record shows the following regimes: first the applied wellbore pressure balances the reservoir pressure, then after the compressive circumferential hole stresses are overcome, tensile stresses are induced on the inside surface of the hole. When the magnitude of these stresses reach the tensile failure stress of the surrounding rock medium, a fracture is initiated and propagates into the reservoir. [1] In standard theories this pressure, the so called breakdown pressure, is the peak pressure in the down-hole pressure record. However experimental investigations [2] show that the breakdown did not occur even if a fracture was initiated at the borehole wall. Drilling muds had the tendency to seal and stabilize fractures and prevent fracture propagation. Also fracture mechanics analysis of breakdown process in mini-frac or leak off tests [3] show that the breakdown pressure could be either equal or larger than the fracture initiation pressure. In order to gain a deeper understanding of the breakdown process in reservoir rock, numerical investigations using the extended finite element method (XFEM) for hydraulic fracturing of porous materials [4] are discussed. The reservoir rock is assumed to be pre-fractured. During pressurization of the borehole, the injection pressure, the pressure distribution and the position of the highest flux along the fracture for different fracturing fluid viscosities are recorded and the influence of the aforementioned values on the stability of fracture propagation is discussed. [1] YEW, C. H. (1997), "Mechanics of Hydraulic Fracturing", Gulf Publishing Company [2] MORITA, N.; BLACK, A. D.; FUH, G.-F. (1996), "Borehole Breakdown Pressure with Drilling Fluids". International Journal of Rock Mechanics and Mining Sciences 33, pp. 39-51 [3] DETOURNAY, E.; CARBONELL, R. (1996), "Fracture Mechanics Analysis of the Breakdown Process in Minifrac or Leakoff Test", Society of Petroleum

  5. Results of hydraulic tests at Gibson Dome No. 1, Elk Ridge No. 1, and E. J. Kubat boreholes, Paradox Basin, Utah

    International Nuclear Information System (INIS)

    Thackston, J.W.; Preslo, L.M.; Hoexter, D.E.; Donnelly, N.

    1984-03-01

    Hydraulic testing was conducted in three boreholes in southeastern Utah to provide a portion of the data needed to characterize the hydrogeology of the Elk Ridge and Gibson Dome areas of the western Paradox Basin, Utah. The tests at the E. J. Kubat borehole yielded representative values of transmissivity, hydraulic conductivity, storativity, and potentiometric levels of the Leadville Limestone. Testing at Elk Ridge No. 1 provided values of similar parameters for the combined thickness of the upper Honaker Trail, Elephant Canyon, and Cedar Mesa formations. Composite transmissivities of similar zones from these borehole tests compared closely with the results of testing at borehole GD-1. A comparison of results from lab tests on core with results of extensive borehole testing at GD-1 indicates that short-term drill stem tests in a single well can provide representative estimates of bulk transmissivities and hydraulic conductivities in this field area for test zones that have a hydraulic conductivity of greater than about 1 x 10 -7 cm/sec. However, lab tests produce more representative values of effective porosity and matrix permeability of individual strata. Results of lab tests and long-term borehole tests confirm that the lower Honaker Trail and upper Paradox formations have extremely low conductivities in the vicinity of the GD-1 borehole. The results of these tests were complete as of January 1981. 22 references, 29 figures, 5 tables

  6. Borehole plugging by compaction process. Final report

    International Nuclear Information System (INIS)

    Fernandez, R.; MacGowan, C.; Nolan, E.; Morey, R.; Palty, A.

    1976-08-01

    The requirements of an overall program to preserve the integrity of a repository formation are documented. The repository is intended to be in stable earth stratum used as a safe and permanent storage area for nuclear waste material. These wastes represent an environmental hazard for a period of up to 200,000 years. An engineering analysis, a reliability and quality-assurance program, and a development program for borehole plugging by compaction process, using natural earthen materials, are presented. Part 1 provides the engineering analysis of downhole compaction methods and related instrumentation along with a recommended development plan from concept through a pilot in-situ experiment. Part 2 provides a reliability and quality-assurance program from laboratory testing of materials through an in-situ experiment

  7. Filling bore-holes with explosive

    Energy Technology Data Exchange (ETDEWEB)

    Alfredsson, S H

    1965-03-02

    In this device for filling boreholes formed in a rock formation with particulate explosive, the explosive is conveyed into the hole by means of a pressure fluid through a tube which has a lesser diameter than the hole. The tube is characterized by a lattice work arranged externally on it, and having a structure adapted to allow passage of a pressure fluid returning between the tube and the wall of the hole, but retaining particles of explosive entrained by the returning pressure fluid. In another arrangement of the device, the lattice work has the form of a brush, including filaments or bristles which are dimensioned to bridge the spacing between the tube and the wall of the hole. (12 claims)

  8. Temperature profiles in the Harwell boreholes

    International Nuclear Information System (INIS)

    Robins, N.S.

    1983-03-01

    Heat flow at Harwell is estimated at 45 mWm -2 (milli Watt per metre squared is the unit of heat flow). Thermal conductivity values for the formations penetrated range from 1.0 to 4.6 Wm -1 K -1 . The temperature profiles recorded in the boreholes enable the vertical groundwater flow patterns within two poorly permeable mudrock units to be evaluated. The two mudrock units act as leaky barriers each separating a pair of aquifer units which induce a vertical hydraulic gradient across the mudrocks. The flow velocity results for the upper mudrock units derived from the temperature profile are compatible with values for groundwater potential derived from hydraulic data (10 -9 ms -1 from the temperature profile and 10 -12 ms -1 from the hydraulic observations). The results from the lower mudrock sequence are incompatible and this may be due to some other overiding influence upon the temperature profile. (author)

  9. Multiple position borehole extensometer procedure: Final draft

    International Nuclear Information System (INIS)

    1986-08-01

    The purpose of the Multiple Position Borehole Extensometer Procedure is to provide detailed information for MPBXs installed at the salt Deaf Smith County ESF. This procedure includes design of equipment, installation, instructions, instrument locations, measurement requirements, support requirements, quality assurance procedures, and data acquisition requirements. Data reduction procedures are also discussed; however, the relevance of the data is discussed elsewhere in the appropriate test plans. Sufficient detail is provided in this procedure to allow for integrating the requirements of this procedure into both the facility construction and overall underground testing programs; identifying necessary equipment for procurement; determining data acquisition requirements as input to Automatic Data Acquisition System (ADAS) design; providing step-by-step procedures for training personnel as well as for directing field operations; establishing quality assurance (QA) checkpoints and implementation methods; and defining data reduction methods and providing the anticipated accuracy of the system. 11 refs., 14 figs

  10. Waste package emplacement borehole option study

    International Nuclear Information System (INIS)

    Streeter, W.S.

    1992-03-01

    This study evaluates the cost and thermal effects of various waste package emplacement configurations that differ in emplacement orientation, number of containers per borehole, and standoff distance at the potential Yucca Mountain nuclear waste repository. In this study, eight additional alternatives to the vertical and horizontal orientation options presented in the Site Characterization Plan Conceptual Design Report are considered. Typical panel layout configurations based on thermal analysis of the waste and cost estimates for design and construction, operations, and closure and decommissioning were made for each emplacement option. For the thermal analysis average waste 10 years out of reactor and the SIM code were used to determine whether the various configurations temperatures would exceed the design criteria for temperature. This study does not make a recommendation for emplacement configuration, but does provide information for comparison of alternatives

  11. Borehole sealing with highly compactd Na bentonite

    International Nuclear Information System (INIS)

    Pusch, R.

    1981-12-01

    This report describes the use of highly compacted Na bentonite for borehole plugging. Bentonites have an extremely low permeability and a low diffusivity, and a swelling ability which produces a nonleaching boundary between clay and rock if the initial bulk density of the bentonite is sufficiently high. The suggested technique, which is applicable to long vertical, and inclined, as well as horizontal boreholes, is based on the use of perforated copper pipes to insert elements of compacted bentonite. Such pipe segments are connected at the rock surface and successively inserted in the hole. When the hole is equipped, the clay takes up water spontaneously and swells through the perforation, and ultimately forms an almost completely homogenous clay core. It embeds the pipe which is left in the hole. Several tests were conducted in the laboratory and one field test was run in Stripa. They all showed that a gel soon fills the slot between the pipe and the confinement which had the form of metal pipes in the laboratory investigations. Subsequently, more clay migrates through the perforation and produces a stiff clay filling in the slot. The redistribution of minerals, leading ultimately to a high degree of homogeneity, can be described as a diffusion process. The rate of redistribution depends on the joint geometry and water flow pattern in the rock. In the rock with an average joint frequence of one per meter or higher, very good homogeneity and sealing ability of the clay are expected within a few months after the application of the plug. (author)

  12. A system utilizing radio frequency identification (RFID) technology to monitor individual rodent behavior in complex social settings.

    Science.gov (United States)

    Howerton, Christopher L; Garner, Joseph P; Mench, Joy A

    2012-07-30

    Pre-clinical investigation of human CNS disorders relies heavily on mouse models. However these show low predictive validity for translational success to humans, partly due to the extensive use of rapid, high-throughput behavioral assays. Improved assays to monitor rodent behavior over longer time scales in a variety of contexts while still maintaining the efficiency of data collection associated with high-throughput assays are needed. We developed an apparatus that uses radio frequency identification device (RFID) technology to facilitate long-term automated monitoring of the behavior of mice in socially or structurally complex cage environments. Mice that were individually marked and implanted with transponders were placed in pairs in the apparatus, and their locations continuously tracked for 24 h. Video observation was used to validate the RFID readings. The apparatus and its associated software accurately tracked the locations of all mice, yielding information about each mouse's location over time, its diel activity patterns, and the amount of time it was in the same location as the other mouse in the pair. The information that can be efficiently collected in this apparatus has a variety of applications for pre-clinical research on human CNS disorders, for example major depressive disorder and autism spectrum disorder, in that it can be used to quantify validated endophenotypes or biomarkers of these disorders using rodent models. While the specific configuration of the apparatus described here was designed to answer particular experimental questions, it can be modified in various ways to accommodate different experimental designs. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Site characterization and validation - equipment design and techniques used in single borehole hydraulic testing, simulated drift experiment and crosshole testing

    International Nuclear Information System (INIS)

    Holmes, D.C.; Sehlstedt, M.

    1991-10-01

    This report describes the equipment and techniques used to investigate the variation of hydrogeological parameters within a fractured crystalline rock mass. The testing program was performed during stage 3 of the site characterization and validation programme at the Stripa mine in Sweden. This programme used a multidisciplinary approach, combining geophysical, geological and hydrogeological methods, to determine how groundwater moved through the rock mass. The hydrogeological work package involved three components. Firstly, novel single borehole techniques (focused packer testing) were used to determine the distribution of hydraulic conductivity and head along individual boreholes. Secondly, water was abstracted from boreholes which were drilled to simulate a tunnel (simulated drift experiment). Locations and magnitudes of flows were measured together with pressure responses at various points in the SCV rock mass. Thirdly, small scale crosshole tests, involving detailed interference testing, were used to determine the variability of hydrogeological parameters within previously identified, significant flow zones. (au)

  14. Final storage of radioactive waste in deep boreholes

    International Nuclear Information System (INIS)

    Eichmeyer, H.; Wolff, H.

    1985-01-01

    The plans of the Danish Atomic Energy Authority expect the storage of 4500 containers with high activity waste each weighing 15 tonnes in deep boreholes in rock salt over a period of 30 years. The Danish plans are concerned with the storage medium salt in one of the many salt mines in North Germany and Denmark with a depth of 1200 metres, because of the high plasticity, good thermal conductivity and non-permeability to liquids and gases. Eight deep boreholes with a diameter of 750 mm are provided in a circle of radius r=250 metres. With a deviation of 0 , the boreholes will be piped down to 1000 metres and after completion, will be filled with clay slurry and barium sulphate. At the start of storage of the waste in containers 6.8 metres long, the clay slurry is replaced by cement slurry with saturated NaCl solution. Another possibility is to fill the borehole volume with saturated NaCl solution, in order to let the convergence act on the annular space between the container and the borehole wall. After filling the borehole, the open borehole should be sealed over a distance of 200 metres with rock salt and over 50 metres with a concrete stopper. It is planned to provide a dense and corrosion-proof seal with bitumen above the concrete. (orig./GB) [de

  15. Laboratory studies of fluid flow through borehole seals

    International Nuclear Information System (INIS)

    South, D.L.

    1983-01-01

    Boreholes in the vicinity of a nuclear waste repository must be reliably sealed to prevent rapid migration of radionuclide contaminated water from the vicinity of the repository to the accessible environment. Few data currently exist regarding the effectiveness of borehole sealing. The objective of this research was to assess the performance of borehole seals under laboratory conditions, particularly with regard to varying stress fields. The approach used to evaluate borehole seals was to compare flow through a sealed borehole with flow through intact rock. Granite, basalt, and tuff were tested, using either cement or bentonite as the seal material. The main conclusions reached as a result of the experiments is that currently existing materials are capable of forming high quality seals when placed under laboratory conditions. Variation of triaxial stress state about a borehole does not significantly affect seal performance if the rock is stiffer than the seal material. Temperature/moisture variations (drying) degraded the quality of cement seals significantly. Performance partially recovered upon resaturation. Significant remaining questions include field emplacement techniques; field vertification of plug quality; plug performance over long time periods, particularly with respect to temperature/moisture variations and chemical stability; and radionuclide sorption capabilities. Scale effects are also important, as shafts and drifts must be sealed as well as larger diameter boreholes

  16. Difference flow measurements in borehole KOV01 at Oskarshamn

    International Nuclear Information System (INIS)

    Poellaenen, J.; Rouhiainen, P.

    2001-09-01

    Posiva Flow Log/Difference Flow method can be used for relatively fast determination of hydraulic conductivity and hydraulic head in fractures or fractured zones in cored boreholes. This report presents the principles of the method as well as the results of the measurements carried out in borehole KOV01 at Oskarshamn in February and March 2001. The aim of the measurements presented in this report was to determine the depth and flow rate of flowing fractures in borehole KOV01 prior to groundwater sampling. The measurements in borehole KOV01 were carried out between 100-1000 m depth using the so called detailed flow logging mode; the flow rate into a 5 m long test section was measured. Detailed flow logging was repeated at the location of the detected flow anomalies using 0.5 m section length and 0.1 m point intervals. The borehole was pumped during these measurements. The occurrence of saline water in the borehole was studied by electric conductivity measurements. The flow guide encloses also an electrode for measuring of single point resistance of the bedrock. It was measured with 0.01 m point intervals during the detailed flow logging. Depth calibration was made on the basis of the known depth marks in the borehole. The depth marks were detected by caliper measurements and by single point resistance measurements

  17. 6LiF sandwich type detectors for low dose individual monitoring in mixed neutron-photon fields

    International Nuclear Information System (INIS)

    Olko, P.; Budzanowski, M.; Bilski, P.; Burgkhardt, B.; Piesch, E.

    1994-01-01

    ICRP Publication 60 recommends the reduction of the annual dose limit for occupational exposure from 50 to 20 mSv and a doubling of the quality factor for medium energy neutrons. If occupational doses are evaluated every month (which is obligatory e.g. in Germany and in Poland), the individual neutron dosemeter will have to measure neutron doses in the range of 100 μSv. No commercially available, automatic individual dosimetry monitoring system exists that fulfils this requirement. Some of the parameters which influence the evaluation of the neutron dose from readings of TL dosemeters have been studied in order to decrease the variance of the measured neutron signal. In mixed neutron-photon fields, clear separation of the neutron component from the total reading depends also on the uncertainty of the gamma dose measurements. While the thermal albedo neutrons are absorbed mostly at the surface of the 6 LiF detector, the reduction of the detector thickness results in a decrease of its photon sensitivity, while its neutron sensitivity is almost principally maintained. As a consequence, the uncertainty of gamma dose contributes with lower weight to the variance of the evaluated neutron signal. First tests of an optimised 200 μm thick sandwich detector and 0.9 mm thick standard LiF chips were made at low neutron and photon dose ranges using different readers, in order to determine the uncertainty versus dose for different neutron-photon combinations. The conditions under which the new sandwich type detectors may improve albedo neutron dosimetry are demonstrated. (Author)

  18. Waste Handling and Emplacement Options for Disposal of Radioactive Waste in Deep Boreholes.

    Energy Technology Data Exchange (ETDEWEB)

    Cochran, John R.; Hardin, Ernest

    2015-11-01

    Traditional methods cannot be used to handle and emplace radioactive wastes in boreholes up to 16,400 feet (5 km) deep for disposal. This paper describes three systems that can be used for handling and emplacing waste packages in deep borehole: (1) a 2011 reference design that is based on a previous study by Woodward–Clyde in 1983 in which waste packages are assembled into “strings” and lowered using drill pipe; (2) an updated version of the 2011 reference design; and (3) a new concept in which individual waste packages would be lowered to depth using a wireline. Emplacement on coiled tubing was also considered, but not developed in detail. The systems described here are currently designed for U.S. Department of Energy-owned high-level waste (HLW) including the Cesium- 137/Strontium-90 capsules from the Hanford Facility and bulk granular HLW from fuel processing in Idaho.

  19. Waste Handling and Emplacement Options for Disposal of Radioactive Waste in Deep Boreholes

    International Nuclear Information System (INIS)

    Cochran, John R.; Hardin, Ernest

    2015-01-01

    Traditional methods cannot be used to handle and emplace radioactive wastes in boreholes up to 16,400 feet (5 km) deep for disposal. This paper describes three systems that can be used for handling and emplacing waste packages in deep borehole: (1) a 2011 reference design that is based on a previous study by Woodward-Clyde in 1983 in which waste packages are assembled into ''strings'' and lowered using drill pipe; (2) an updated version of the 2011 reference design; and (3) a new concept in which individual waste packages would be lowered to depth using a wireline. Emplacement on coiled tubing was also considered, but not developed in detail. The systems described here are currently designed for U.S. Department of Energy-owned high-level waste (HLW) including the Cesium- 137/Strontium-90 capsules from the Hanford Facility and bulk granular HLW from fuel processing in Idaho.

  20. BASIMO - Borehole Heat Exchanger Array Simulation and Optimization Tool

    Science.gov (United States)

    Schulte, Daniel O.; Bastian, Welsch; Wolfram, Rühaak; Kristian, Bär; Ingo, Sass

    2017-04-01

    Arrays of borehole heat exchangers are an increasingly popular source for renewable energy. Furthermore, they can serve as borehole thermal energy storage (BTES) systems for seasonally fluctuating heat sources like solar thermal energy or district heating grids. The high temperature level of these heat sources prohibits the use of the shallow subsurface for environmental reasons. Therefore, deeper reservoirs have to be accessed instead. The increased depth of the systems results in high investment costs and has hindered the implementation of this technology until now. Therefore, research of medium deep BTES systems relies on numerical simulation models. Current simulation tools cannot - or only to some extent - describe key features like partly insulated boreholes unless they run fully discretized models of the borehole heat exchangers. However, fully discretized models often come at a high computational cost, especially for large arrays of borehole heat exchangers. We give an update on the development of BASIMO: a tool, which uses one dimensional thermal resistance and capacity models for the borehole heat exchangers coupled with a numerical finite element model for the subsurface heat transport in a dual-continuum approach. An unstructured tetrahedral mesh bypasses the limitations of structured grids for borehole path geometries, while the thermal resistance and capacity model is improved to account for borehole heat exchanger properties changing with depth. Thereby, partly insulated boreholes can be considered in the model. Furthermore, BASIMO can be used to improve the design of BTES systems: the tool allows for automated parameter variations and is readily coupled to other code like mathematical optimization algorithms. Optimization can be used to determine the required minimum system size or to increase the system performance.

  1. 24-CHANNEL GEOPHONE ARRAY FOR HORIZONTAL OR VERTICAL BOREHOLES

    Energy Technology Data Exchange (ETDEWEB)

    Erik C. Westman

    2003-10-24

    Improved ground-imaging capabilities have enormous potential to increase energy, environmental, and economic benefits by improving exploration accuracy and reducing energy consumption during the mining cycle. Seismic tomography has been used successfully to monitor and evaluate geologic conditions ahead of a mining face. A primary limitation to existing seismic tomography, however, is the placement of sensors. The goal of this project is to develop an array of 24 seismic sensors capable of being mounted in either a vertical or horizontal borehole. Development of this technology reduces energy usage in excavation, transportation, ventilation, and processing phases of the mining operation because less waste is mined and the mining cycle suffers fewer interruptions. This new technology benefits all types of mines, including metal/nonmetal, coal, and quarrying. The primary research tasks focused on sensor placement method, sensor housing and clamping design, and cabling and connector selection. An initial design is described in the report. Following assembly, a prototype was tested in the laboratory as well as at a surface stone quarry. Data analysis and tool performance were used for subsequent design modifications. A final design is described, of which several components are available for patent application. Industry partners have shown clear support for this research and demonstrated an interest in commercialization following project completion.

  2. Advances in directional borehole radar data analysis and visualization

    Science.gov (United States)

    Smith, D.V.G.; Brown, P.J.

    2002-01-01

    The U.S. Geological Survey is developing a directional borehole radar (DBOR) tool for mapping fractures, lithologic changes, and underground utility and void detection. An important part of the development of the DBOR tool is data analysis and visualization, with the aim of making the software graphical user interface (GUI) intuitive and easy to use. The DBOR software system consists of a suite of signal and image processing routines written in Research Systems' Interactive Data Language (IDL). The software also serves as a front-end to many widely accepted Colorado School of Mines Center for Wave Phenomena (CWP) Seismic UNIX (SU) algorithms (Cohen and Stockwell, 2001). Although the SU collection runs natively in a UNIX environment, our system seamlessly emulates a UNIX session within a widely used PC operating system (MicroSoft Windows) using GNU tools (Noer, 1998). Examples are presented of laboratory data acquired with the prototype tool from two different experimental settings. The first experiment imaged plastic pipes in a macro-scale sand tank. The second experiment monitored the progress of an invasion front resulting from oil injection. Finally, challenges to further development and planned future work are discussed.

  3. A plot-scale study of firn stratigraphy at Lomonosovfonna, Svalbard, using ice cores, borehole video and GPR surveys in 2012-14

    DEFF Research Database (Denmark)

    Marchenko, Sergey; Pohjola, Veijo A.; Pettersson, Rickard

    2017-01-01

    Spatial heterogeneity of snow and firn properties on glaciers introduces uncertainty in interpretation of point and profile observations and complicates modelling of meltwater percolation and runoff. Here we present a study of the temporal and spatial dynamics of firn density and stratigraphy...... at the plot-scale (≈10 m × 10 m × 10 m) repeated annually during 2012-14 at the Lomonosovfonna icefield, Svalbard. Results from cores, video inspections in boreholes and radar grid surveys are compared. Ice layers 0.1-50 cm thick comprised ≈8% of the borehole length. Most of them are 1-3 cm thick and could...... in individual boreholes. However, the match between the high amplitude peaks in the grid-averaged radar signal and horizons of preferential ice layer formation revealed by averaging the video surveys over multiple boreholes is higher. These horizons are interpreted as buried firn layers previously exposed...

  4. Technical requirements for implementation of an individual monitoring service for evaluation of operational quantity HP(10) using thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Francisco, Adelaide Benedita Armando

    2016-01-01

    This work aims to establish technical requirements for the development of a TLDs system for the assessment of operational quantity H P (10), in order to implement an external individual monitoring service in countries who do not have. This allows a better understanding of the technic and the thermoluminescent dosimetry system, thus contributing to identify the technical criteria to be followed by a dosimetry laboratory and evaluation of the dosimetric system performance. For this, the review of the specific literature of the dosimetry field was conducted and later the type and performance tests that must be followed by a dosimetric system were reproduced in practice. In additional was made a analysis of internationals standards norms and the technical regulation used in Brazil, to define the essentials type testes to a dosimetric system. To check the performance of a dosimetry system, a performance analysis of the Brazilian TLDs system was carried out over the past 6 years using the trumpet curve, where it was observed that most of TLDs system, in this review period, were approved and have excellent performance. The technical requirements for the development of a thermoluminescent dosimetry system ensure that the system provides technically reliable results and allow demonstration of compliance with the standard criteria established by national and international standards, and the implementation of the dosimetry system, is verified the compliance of the annual doses limits set for occupationally exposed. (author)

  5. Borehole drilling for sewage disposal at Asuka Station, East Antarctica

    OpenAIRE

    Ishizawa,Kenji; Takahashi,Akiyoshi

    1994-01-01

    A borehole for sewage disposal was drilled at Asuka Station (71°31′34″S, 24°08′17″E, 930m a. s. l.) in January 1987. The borehole, 400mm in diameter and 27.5m in depth, was drilled 50m distant from the main hut using a steam drilling system. The drilling speed was 4m/h between the snow surface and 20m depth. The total amount of kerosene used for melting snow and steam generation was 110/. Sewage stored in the tank was directed to the borehole through a heated pipe. The cumulative amount of se...

  6. Design of a slimline directional borehole radar antenna using FDTD

    CSIR Research Space (South Africa)

    Vogt, D

    2008-06-01

    Full Text Available , dielectric. I. INTRODUCTION Borehole radar is the application of Ground Penetrating Radar (GPR) within a borehole [11]. GPR is a technique used to delineate structures and features of a subsurface. The borehole radar technique has been used successfully..., the direction of the incoming EM wave can be determined [6]. III. FILLER MATERIAL INSIDE ANTENNA ARRAY Ideally, there is no material between the antenna body and the rock surrounding it. In that case, the filler material would be matched to the dielectric...

  7. Digital signal processing of data from borehole creep closure

    International Nuclear Information System (INIS)

    Chakrabarti, S.; Patrick, W.C.; Duplancic, N.

    1987-01-01

    Digital signal processing, a technique commonly used in the fields of electrical engineering and communication technology, has been successfully used to analyze creep closure data obtained from a 0.91 m diameter by 5.13 deep borehole in bedded salt. By filtering the ''noise'' component of the closure data from a test borehole, important data trends were made more evident and average creep closure rates were able to be calculated. This process provided accurate estimates of closure rates that are used in the design of lined boreholes in which heat-generating transuranic nuclear wastes are emplaced at the Waste Isolation Pilot Plant

  8. Oman Drilling Project Phase I Borehole Geophysical Survey

    Science.gov (United States)

    Matter, J. M.; Pezard, P. A.; Henry, G.; Brun, L.; Célérier, B.; Lods, G.; Robert, P.; Benchikh, A. M.; Al Shukaili, M.; Al Qassabi, A.

    2017-12-01

    The Oman Drilling Project (OmanDP) drilled six holes at six sites in the Samail ophiolite in the southern Samail and Tayin massifs. 1500-m of igneous and metamorphic rocks were recovered at four sites (GT1, GT2, GT3 and BT1) using wireline diamond core drilling and drill cuttings at two sites (BA1, BA2) using air rotary drilling, respectively. OmanDP is an international collaboration supported by the International Continental Scientific Drilling Program, the Deep Carbon Observatory, NSF, NASA, IODP, JAMSTEC, and the European, Japanese, German and Swiss Science Foundations, and with in-kind support in Oman from Ministry of Regional Municipalities and Water Resources, Public Authority of Mining, Sultan Qaboos University and the German University of Technology. A comprehensive borehole geophysical survey was conducted in all the OmanDP Phase I boreholes shortly after drilling in April 2017. Following geophysical wireline logs, using slim-hole borehole logging equipment provided and run by the Centre National De La Recherche Scientifique (CNRS) and the Université de Montpellier/ Géosciences Montpellier, and logging trucks from the Ministry of Regional Municipalities and Water Resources, were collected in most of the holes: electrical resistivity (dual laterolog resistivity, LLd and LLs), spectral gamma ray (K, U, and Th contents), magnetic susceptibility, total natural gamma ray, full waveform sonic (Vp and Vs), acoustic borehole wall imaging, optical borehole wall imaging, borehole fluid parameters (pressure, temperature, electrical conductivity, dissolved oxygen, pH, redox potential, non-polarized spontaneous electrical potential), and caliper (borehole diameter). In addition, spinner flowmeter (downhole fluid flow rate along borehole axis) and heatpulse flow meter logs (dowhole fluid flow rate along borehole axis) were collected in BA1 to characterize downhole fluid flow rates along borehole axis. Unfortuantely, only incomplete wireline logs are available for

  9. Development and characterization of two-component albedo based neutron individual monitoring system using thermoluminescent detectors; Desenvolvimento e caracterizacao de um sistema de monitoracao individual de neutrons tipo albedo de duas componentes usando detectores termoluminescentes

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Marcelo Marques

    2008-07-01

    A TLD-albedo based two-component neutron individual monitoring system was developed and characterized in this work. The monitor consists of a black plastic holder, an incident neutron boron loaded shield, a moderator polyethylene body (to increase its response), two pairs of TLD-600 and TLD-700 (one pair to each component) and an adjustable belt. This monitoring system was calibrated in thermal neutron fields and in 70 keV, 144 keV, 565 keV, 1.2 MeV and 5 MeV monoenergetic neutron fields. In addition, it was calibrated in {sup 252C}f(D{sub 2}O), {sup 252}Cf, {sup 241}Am-B, {sup 241}Am-Be and {sup 238}Pu-Be source fields. For the latter, the lower detection levels are, respectively, 0.009 mSv, 0.06 mSv, 0.12 mSv, 0.09 mSv and 0.08 mSv. The participation in an international intercomparison sponsored by IAEA with simulated workplace fields validated the system. The monitoring system was successfully characterized in the ISO 21909 standard and in an IRD - the Brazilian Institute for Radioprotection and Dosimetry - technical regulation draft. Nowadays, the neutron individual system is in use by IRD for whole body individual monitoring of five institutions, which comprehend several activities. (author)

  10. Numerical Modeling of a Shallow Borehole Thermal Energy Storage System

    Science.gov (United States)

    Catolico, N.; Ge, S.; Lu, N.; McCartney, J. S.

    2014-12-01

    Borehole thermal energy storage (BTES) combined with solar thermal energy harvesting is an economic technological system to garner and store energy as well as an environmentally-sustainable alternative for the heating of buildings. The first community-scale BTES system in North America was installed in 2007 in the Drake Landing Solar Community (DLSC), about 35 miles south of Calgary, Canada. The BTES system involves direct circulation of water heated from solar thermal panels in the summer into a storage tank, after which it is circulate within an array of 144 closed-loop geothermal heat exchangers having a depth of 35 m and a spacing of 2.5 m. In the winter the circulation direction is reversed to supply heat to houses. Data collection over a six year period indicates that this system can supply more than 90% of the winter heating energy needs for 52 houses in the community. One major challenge facing the BTES system technology is the relatively low annual efficiency, i.e., the ratio of energy input and output is in the range of 15% to 40% for the system in Drake Landing. To better understand the working principles of BTES and to improve BTES performance for future applications at larger scales, a three-dimensional transient coupled fluid and heat transfer model is established using TOUGH2. The time-dependent injection temperatures and circulation rate measured over the six years of monitoring are used as model input. The simulations are calibrated using soil temperature data measured at different locations over time. The time-dependent temperature distributions within the borehole region agree well with the measured temperatures for soil with an intrinsic permeability of 10e-19 m2, an apparent thermal conductivity of 2.03 W/m°C, and a volumetric heat capacity of 2.31 MJ/m-3°C. The calibrated model serves as the basis for a sensitivity analysis of soil and operational parameters on BTES system efficiency preformed with TOUGH2. Preliminary results suggest 1) BTES

  11. BoreholeAR: A mobile tablet application for effective borehole database visualization using an augmented reality technology

    Science.gov (United States)

    Lee, Sangho; Suh, Jangwon; Park, Hyeong-Dong

    2015-03-01

    Boring logs are widely used in geological field studies since the data describes various attributes of underground and surface environments. However, it is difficult to manage multiple boring logs in the field as the conventional management and visualization methods are not suitable for integrating and combining large data sets. We developed an iPad application to enable its user to search the boring log rapidly and visualize them using the augmented reality (AR) technique. For the development of the application, a standard borehole database appropriate for a mobile-based borehole database management system was designed. The application consists of three modules: an AR module, a map module, and a database module. The AR module superimposes borehole data on camera imagery as viewed by the user and provides intuitive visualization of borehole locations. The map module shows the locations of corresponding borehole data on a 2D map with additional map layers. The database module provides data management functions for large borehole databases for other modules. Field survey was also carried out using more than 100,000 borehole data.

  12. Development of a Lunar Borehole Seismometer

    Science.gov (United States)

    Passmore, P. R.; Siegler, M.; Malin, P. E.; Passmore, K.; Zacny, K.; Avenson, B.; Weber, R. C.; Schmerr, N. C.; Nagihara, S.

    2017-12-01

    Nearly all seismic stations on Earth are buried below the ground. Burial provides controlled temperatures and greater seismic coupling at little cost. This is also true on the Moon and other planetary bodies. Burial of a seismometer under just 1 meter of lunar regolith would provide an isothermal environment and potentially reduce signal scattering noise by an order of magnitude. Here we explain how we will use an existing NASA SBIR and PIDDP funded subsurface heat flow probe deployment system to bury a miniaturized, broadband, optical seismometer 1 meter below the lunar surface. The system is sensitive, low mass and low power. We believe this system offers a compelling architecture for NASA's future seismic exploration of the solar system. We will report on a prototype 3-axis, broadband seismometer package that has been tested under low pressure conditions in lunar-regolith simulant. The deployment mechanism reaches 1m depth in less than 25 seconds. Our designed and tested system: 1) Would be deployed at least 1m below the lunar surface to achieve isothermal conditions without thermal shielding or heaters, increase seismic coupling, and decrease noise. 2) Is small (our prototype probe is a cylinder 50mm in diameter, 36cm long including electronics, potentially as small as 10 cm with sensors only). 3) Is low-mass (each sensor is 0.1 kg, so an extra redundancy 4-component seismograph plus 1.5 kg borehole sonde and recorder weighs less than 2 kg and is feasibly smaller with miniaturized electronics). 4) Is low-power (our complete 3-sensor borehole seismographic system's power consumption is about half a Watt, or 7% of Apollo's 7.1 W average and 30% of the InSight SEIS's 1.5W winter-time heating system). 5) Is broadband and highly sensitive (the "off the shelf" sensors have a wide passband: 0.005-1000 Hz - and high dynamic range of 183 dB (or about 10-9g Hz-1/2, with hopes for simple modifications to be at least an order of magnitude better). Burial also aids the

  13. COMPLETION OF THE TRANSURANIC GREATER CONFINEMENT DISPOSAL BOREHOLE PERFORMANCE ASSESSMENT FOR THE NEVADA TEST SITE

    International Nuclear Information System (INIS)

    Colarusso, Angela; Crowe, Bruce; Cochran, John R.

    2003-01-01

    assessment, inclusion of dose calculations from collocated low-level waste in the boreholes for the individual protection requirements, further assessments of engineered barriers and conditions associated with the assurance requirements, and expansion of documentation provided for assessing the groundwater protection requirements. The Transuranic Waste Disposal Federal Review Group approved the performance assessment for Greater Confinement Disposal boreholes in 2001 and did not approve the Application of the Assurance Requirements. Remaining issues concerned with engineered barriers and the multiple aspects of the Assurance Requirements will be resolved at the time of closure of the Area 5 Radioactive Waste Management Site. This is the first completion and acceptance of a performance assessment for transuranic materials under the U.S. Department of Energy self-regulation. The Greater Confinement Disposal boreholes are only the second waste disposal configuration to meet the safety regulatory requirements of 40 CFR 191

  14. Research borehole drilling activity for boreholes DH-18, DH-19, DC-12, DC-13, DC-14, DC-15, and deepening of existing borehole DC-7

    International Nuclear Information System (INIS)

    1979-09-01

    This report is an environmental evaluation of the impacts of proposed borehole drilling activities at the Hanford Site, northwest of Richland, Washington. The proposed action is to drill six research boreholes ranging in depth from 137 to 1372 meters (m) [250 to 4500 +- feet (ft)]. In addition, an existing borehole (DC-7) will be extended from 1249 to 1524 m (4099 to 5000 +- ft). The purpose of the US Department of Energy's (DOE) borehole drilling activities is to collect data on in situ rock formations that are considered potentialy suitable for nuclear waste repositories. The technical program efforts necessary to identify and qualify specific underground waste facility sites in candidate rock formations include geologic and hydrologic studies (seismicity and tectonics, rock structure and stratigraphy, lithology, etc.). Borehole drilling is an integral part of the geological studies and is essential to a thorough understanding of potentially suitable geologic formations. The purpose of the proposed drilling activities is to obtain data for evaluating Columbia River basalts that are being evaluated by the National Waste Terminal Storage (NWTS) Program to determine their suitability potential for nuclear waste repositories. Unavoidable impact to the environment is limited primarily to the clearing of land needed for access and drilling operations. Considerations exercised during site preparation, drilling, and subsequent site restoration will limit modification of the natural environment to the minimum required for accomplishment of test objectives

  15. Borehole Breakout Growth and In-Situ Stress Orientation in the Central Scandinavian Caledonides: Results from the Cosc-1 Borehole

    Science.gov (United States)

    Wenning, Q.; Zappone, A.; Berthet, T.; Ask, M. V. S.; Rosberg, J. E.; Almqvist, B. S. G.

    2017-12-01

    Borehole breakouts are often assumed to form near instantaneously due to stress perturbations around boreholes after the rock mass was removed. Recent observations in sediments [e.g., Moore et al., 2011] and crystalline rocks [e.g., Berard and Cornet, 2003], as well as numerical modelling results [e.g., Schoenball et al., 2014], suggest that there are cases in which borehole breakout grows radially over time, forcing us to reconsider subsurface stress estimation. These observations are rare due to drilling difficulties (i.e., cementing and casing the borehole after drilling), often only allowing a single image logging campaign. In 2014, the Collisional Orogeny in the Scandinavian Caledonides deep scientific borehole (COSC-1) was drilled to a depth of 2.5 km. To date the borehole is open and uncased, allowing two acoustic televiewer logging campaigns, with more than one year between campaigns. The borehole is still available for supplementary data collactions. These logs provide detailed images along the full length of the 2.5 km deep borehole with 1.6 km of overlapping logs for breakout and drilling induced tensile fracture analysis. The results show from the sparse occurrence of breakouts and drilling induced tensile fractures a NW-SE average maximum horizontal stress direction, consistent with the general trend in Scandinavia. The unique acquisition of image logs in two successions allows for analysis of time-dependent borehole deformation, indicating that six breakout zones have crept, both along the borehole axis and radially (up to 20° growth) around the borehole. While some breakouts have grown, the formation of new breakouts has not occurred. The occurrence of breakouts and their growth appear to be independent of lithology. The observed growth after the second logging campaign suggests that under conditions where the stress exceeded the strength of the rock, the resulting breakout causes perturbations in the stresses around the borehole in the near

  16. Borehole sealing literature review of performance requirements and materials

    International Nuclear Information System (INIS)

    Piccinin, D.; Hooton, R.D.

    1985-02-01

    To ensure the safe disposal of nuclear wastes, all potential pathways for radionuclide release to the biosphere must be effectively sealed. This report presents a summary of the literature up to August 1982 and outlines the placement, mechanical property and durability-stability requirements for borehole sealing. An outline of the materials that have been considered for possible use in borehole sealing is also included. Cement grouts are recommended for further study since it is indicated in the literature that cement grouts offer the best opportunity of effectively sealing boreholes employing present technology. However, new and less well known materials should also be researched to ensure that the best possible borehole plugging system is developed. 78 refs

  17. Core-logs of borehole VI down to 505 m

    International Nuclear Information System (INIS)

    Carlsson, L.; Olsson, T.; Stejskal, V.

    1981-01-01

    In the hydrogeological program of the Stripa project the vertical borehole V1 has been drilled 505.5 m. The drillcore has been logged with regard to rock characteristic, fracture frequency, dipping and filling. The results presented as cumulative fracture diagram have formed the base for subdivision of the borehole according to fracture frequency. The variation in the fracture dipping was also taken into account. Chlorite is the most common of the infilling material in the fractures. For the borehole 0-466 m the average fracture frequency is 1.46 fractures/m. Below 466 m the core is highly fractured and crushed indicating that the borehole has entered a crushed zone. Because of this the drilling is temporarily stopped. (Auth.)

  18. Global Database of Borehole Temperatures and Climate Reconstructions - CA-0003

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Data collected from borehole site CA-0003. For an accurate assessment of the relative roles of natural variability and anthropogenic influence in the Earth's...

  19. Geophysical borehole logging in the unsaturated zone, Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Schimschal, U.; Nelson, P.H.

    1991-01-01

    Borehole geophysical logging for site characterization in the volcanic rocks at the proposed nuclear waste repository at Yucca Mountain, Nevada, requires data collection under rather unusual conditions. Logging tools must operate in rugose, dry holes above the water table in the unsaturated zone. Not all logging tools will operate in this environment, therefore; careful consideration must be given to selection and calibration. A sample suite of logs is presented that demonstrates correlation of geological formations from borehole to borehole, the definition of zones of altered mineralogy, and the quantitative estimates of rock properties. The authors show the results of an exploratory calculation of porosity and water saturation based upon density and epithermal neutron logs. Comparison of the results with a few core samples is encouraging, particularly because the logs can provide continuous data in boreholes where core samples are not available

  20. Borehole depth and regolith aquifer hydraulic characteristics of ...

    African Journals Online (AJOL)

    EJIRO

    composition tend to exhibit similar hydraulic characteristics. But the poor performance of ... mum borehole depth in the regolith aquifer for the area and also reveals that ..... most important end products of chemical weathering of rocks of granitic ...

  1. Comparative Study of Coliform Contamination of Public Boreholes ...

    African Journals Online (AJOL)

    PROF HORSFALL

    boreholes and pipe borne water supplies within Bosso town. Twenty (20) water ... result from inadequately treated sewage discharged from various septic tanks, and .... enforce proper hygienic practices, especially around public water supply ...

  2. Methods for use in detecting seismic waves in a borehole

    Science.gov (United States)

    West, Phillip B.; Fincke, James R.; Reed, Teddy R.

    2007-02-20

    The invention provides methods and apparatus for detecting seismic waves propagating through a subterranean formation surrounding a borehole. In a first embodiment, a sensor module uses the rotation of bogey wheels to extend and retract a sensor package for selective contact and magnetic coupling to casing lining the borehole. In a second embodiment, a sensor module is magnetically coupled to the casing wall during its travel and dragged therealong while maintaining contact therewith. In a third embodiment, a sensor module is interfaced with the borehole environment to detect seismic waves using coupling through liquid in the borehole. Two or more of the above embodiments may be combined within a single sensor array to provide a resulting seismic survey combining the optimum of the outputs of each embodiment into a single data set.

  3. Methodology for Radiological Risk Assessment of Deep Borehole Disposal Operations

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Ernest; Su, Jiann-Cherng; Peretz, Fred(ORNL)

    2017-03-01

    The primary purpose of the preclosure radiological safety assessment (that this document supports) is to identify risk factors for disposal operations, to aid in design for the deep borehole field test (DBFT) engineering demonstration.

  4. Development of Web based system for individual internal monitoring programme; Desenvolvimento de um sistema baseado na Web para suporte ao programa de monitoracao individual interna do IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Vanessa Rogeria de

    2007-07-01

    The purposes of the internal monitoring, in general, are to verify and document that each worker is protected adequately against risks from radionuclide intakes and the protection complies with legal requirements. Therefore, an overall radiation protection programme, starts with an assessment to identify work situations in which there is a risk of internal contamination of workers and to quantify the likely intake of radioactive material and the resulting committed effective dose. As a part of a continuous improvement of the monitoring programme for occupationally exposed workers at IPEN, it is being developed a Web based system to access the internal dosimetry database. The system was implemented using Hypertext Preprocessor, PHP, and a PostgreSQL database. This system will introduce a new paradigm in the routine of the internal dosimetry service, providing a fast access to the information among the measurement laboratories staff, dose evaluation group and the radiation protection supervisor. The database maintains information about worker identification, physical and chemical characteristics of the radionuclide, type of monitoring, measurement data and the dose. Moreover, this information will be readily available to provide support for regulatory compliance and quality control requirements. (author)

  5. Analysis and interpretation of borehole hydraulic tests in deep boreholes: principles, model development, and applications

    International Nuclear Information System (INIS)

    Pickens, J.F.; Grisak, G.E.; Avis, J.D.; Belanger, D.W.

    1987-01-01

    A review of the literature on hydraulic testing and interpretive methods, particularly in low-permeability media, indicates a need for a comprehensive hydraulic testing interpretive capability. Physical limitations on boreholes, such as caving and erosion during continued drilling, as well as the high costs associated with deep-hole rigs and testing equipment, often necessitate testing under nonideal conditions with respect to antecedent pressures and temperatures. In these situations, which are common in the high-level nuclear waste programs throughout the world, the interpretive requirements include the ability to quantitatively account for thermally induced pressure responses and borehole pressure history (resulting in a time-dependent pressure profile around the borehole) as well as equipment compliance effects in low-permeability intervals. A numerical model was developed to provide the capability to handle these antecedent conditions. Sensitivity studies and practical applications are provided to illustrate the importance of thermal effects and antecedent pressure history. It is demonstrated theoretically and with examples from the Swiss (National Genossenschaft fuer die Lagerung radioaktiver Abfaelle) regional hydrogeologic characterization program that pressure changes (expressed as hydraulic head) of the order of tens to hundreds of meters can results from 1 0 to 2 0 C temperature variations during shut-in (packer isolated) tests in low-permeability formations. Misinterpreted formation pressures and hydraulic conductivity can also result from inaccurate antecedent pressure history. Interpretation of representative formation properties and pressures requires that antecedent pressure information and test period temperature data be included as an integral part of the hydraulic test analyses

  6. Borehole Array Observations of Non-Volcanic Tremor at SAFOD

    Science.gov (United States)

    Ellsworth, W. L.; Luetgert, J. H.; Oppenheimer, D. H.

    2005-12-01

    We report on the observation of non-volcanic tremor made in the San Andreas Fault Observatory at Depth in May, 2005 during the deployment of a multi-level borehole seismic array in the SAFOD main hole. The seismic array consisted of 80 levels of hydraulically-clamped 3-component, 15 Hz omni-directional geophones spaced 15.24 m apart along a 1200 m section of the inclined borehole between 1538 and 2363 m below the ground surface. The array was provided by Paulsson Geophysical Services, Inc. (P/GSI), and recorded at a sample rate of 4000 sps on 24-bit Geode digital recorders provided by Geometrics, Inc. More than 2 TB of continuous data were recorded during the 2-week deployment. Selected local earthquakes and explosions recorded by the array are available at the Northern California Earthquake Data Center, and the entire unedited data set is available as assembled data at the IRIS Data Management Center. Both data sets are currently in the industry standard SEG2 format. Episodes of non-volcanic tremor are common along this reach of the San Andreas Fault according to Nadeau and Dolenc [2004, DOI: 10.1126/science.1107142], with many originating about 30 km southeast of SAFOD beneath the southern end of the Parkfield segment and northern end of the Simmler segment of the fault. We identified tremor episodes using spectrograms routinely produced by the Northern California Seismic Network (http://quake.usgs.gov/cgi-bin/sgrampark.pl) on which they appear as periods of elevated noise relative to the background. A particularly strong tremor episode occurred on May 10, 2005 between 19:39 and 20:00 UTC. In SAFOD, tremor spectral levels exceed the instrumental noise floor to at least 40 Hz. The spatially unaliased recording of the tremor wavefield on the P/GSI array reveal individual phases that can be tracked continuously across the array. The wavefield is composed of both up- and down-going shear waves that form quasi-stationary interference patterns in which areas of

  7. Experimental and Numerical Comparison of Two Borehole Heat Exchangers

    DEFF Research Database (Denmark)

    Alberdi Pagola, Maria; Poulsen, Søren Erbs

    2014-01-01

    This report outlines key results from a comparative study of two different pipe borehole heat exchanger (BHE) configurations. The work was carried out by VIA University College and in collaboration with GM Plast A/S.......This report outlines key results from a comparative study of two different pipe borehole heat exchanger (BHE) configurations. The work was carried out by VIA University College and in collaboration with GM Plast A/S....

  8. Bond strength of cementitious borehole plugs in welded tuff

    International Nuclear Information System (INIS)

    Akgun, H.; Daemen, J.J.K.

    1991-02-01

    Axial loads on plugs or seals in an underground repository due to gas, water pressures and temperature changes induced subsequent to waste and plug emplacement lead to shear stresses at the plug/rock contact. Therefore, the bond between the plug and rock is a critical element for the design and effectiveness of plugs in boreholes, shafts or tunnels. This study includes a systematic investigation of the bond strength of cementitious borehole plugs in welded tuff. Analytical and numerical analysis of borehole plug-rock stress transfer mechanics is performed. The interface strength and deformation are studied as a function of Young's modulus ratio of plug and rock, plug length and rock cylinder outside-to-inside radius ratio. The tensile stresses in and near an axially loaded plug are analyzed. The frictional interface strength of an axially loaded borehole plug, the effect of axial stress and lateral external stress, and thermal effects are also analyzed. Implications for plug design are discussed. The main conclusion is a strong recommendation to design friction plugs in shafts, drifts, tunnels or boreholes with a minimum length to diameter ratio of four. Such a geometrical design will reduce tensile stresses in the plug and in the host rock to a level which should minimize the risk of long-term deterioration caused by excessive tensile stresses. Push-out tests have been used to determine the bond strength by applying an axial load to cement plugs emplaced in boreholes in welded tuff cylinders. A total of 130 push-out tests have been performed as a function of borehole size, plug length, temperature, and degree of saturation of the host tuff. The use of four different borehole radii enables evaluation of size effects. 119 refs., 42 figs., 20 tabs

  9. Observations of joint persistence and connectivity across boreholes

    Energy Technology Data Exchange (ETDEWEB)

    Thapa, B.B.; Karasaki, K.

    1996-01-01

    Observations of joint persistence and connectivity are made by comparison of digital borehole wall images of fractures, fluid conductivity logs and hydraulic injections test results. The fractures were found to be generally impersistent across vertical boreholes about 8 m apart. Many hydraulic connections were found in the same volume of rock. Direct connections through single fractures seem to be rare and connectivity appears to be controlled by fracture networks, even over small volumes.

  10. The experimental results and analysis of a borehole radar prototype

    International Nuclear Information System (INIS)

    Liu, Sixin; Wu, Junjun; Dong, Hang; Fu, Lei; Wang, Fei

    2012-01-01

    A prototype of borehole radar has been successfully tested in three sites for different purposes under a field condition. The objective of the prototype is providing an effective down-hole tool for detecting targets in deep boreholes situated in a relatively high conductivity area such as the metal ores. The first testing site is at a geothermal field. The fractures extending more than 20 m from the borehole are delineated by the borehole radar in the single-hole reflection mode. The second testing site is located in a jade mine for basement evaluation. The cross-hole measurement mode was used to detect the cavities made by previous unorganized mining activities. Several high-velocity anomalies were found in the velocity profile and presumably the targets of the mine shafts and tunnels. The third test site is located in a mineralized belt characterized by low resistivity less than 1000 Ohm m, the surface-borehole measurement was carried out and the data were processed with velocity tomography. The low-velocity zone corresponds to a mineralized zone from geological records. The three testing results proved the readiness of this borehole radar prototype for further deployment in more complicated and realistic field situations. (paper)

  11. Individual monitoring of internal exposure of 131I of workers from the nuclear medicine service FUESMEN, Argentina

    International Nuclear Information System (INIS)

    Arenas, G.; Acosta, N.; Venier, V.; Bedoya Toboo, C.

    2013-01-01

    It is presented the FUESMEN experience in routine monitoring of thyroid internal doses due to inhalation of 131 I in workers of the Nuclear Medicine Service in normal operation or accidental exposure. It is used a surface contamination monitor, type Geiger Mueller, calibrated with a acrylic phantom based on specifications of the simulator of thyroid of ICRU 48 with 131 I reference activity. Through the obtained measurements is achieved to validate the use of Portable Monitor to carry out preliminary exploration on the monitoring scenarios of incidental situations

  12. Production of radioactive sodium under working conditions for investigation into petroleum boreholes

    International Nuclear Information System (INIS)

    Kostin, Yu.I.; Gulin, Yu.A.; Sokolov, Yu.I.; Zhuvagin, I.G.

    1976-01-01

    Because it is advisable to use short-lived isotopes in monitoring the condition of boreholes, procedures are proposed for preparing 0.1-0.5 mC of Na 24 (half-life is 14.9 hr.) during a cycle under production conditions. It is recommended that baking soda should be used as activation material and an ampule polonium and beryllium neutron source with an activity of about 15 to 20 mC should be used as a source. Each operation uses 80 kg of baking soda and the activation lasts 30 to 50 hr

  13. On the Fidelity of “CORK” Borehole Hydrologic Observatory Pressure Records

    Directory of Open Access Journals (Sweden)

    Keir Becker

    2007-09-01

    Full Text Available Long-term formation pressure monitoring in Ocean Drilling Program (ODP and Integrated Ocean Drilling Program (IODP boreholes using evolving Circulation Obviation Retrofit Kit (CORK hydrologic observatory technology has led to unanticipated applications as a result of the growing duration of recording intervals and the improvement of measurement fidelity. Current capabilities provide geologically meaningful observations over a broad range of time scales from static state to 1 Hz, allowing investigations of many coupled hydrologic, geodynamic, and seismologic phenomena. In this review, we present observations that provide constraints on current limits to recording fidelity, and examples of how leakage can affect pressure observations.

  14. Geophysical borehole logging and optical imaging of the boreholes KR34, KR35 and KR36, at Olkiluoto 2005

    Energy Technology Data Exchange (ETDEWEB)

    Majapuro, J. [Suomen Malmi Oy, Espoo (Finland)

    2005-09-15

    Suomen Malmi Oy conducted geophysical borehole logging and optical imaging surveys of the boreholes KR34, KR35 and KR36 at the Olkiluoto site in Eurajoki during May - June 2005. The survey is a part of Posiva Oy's detailed investigation program for the final disposal of spent nuclear fuel. The methods applied are magnetic susceptibility, natural gamma radiation, gamma-gamma density, single point resistance, Wenner-resistivity, borehole radar, full waveform sonic and optical imaging. The assignment included the field work of all surveys, interpretation and processing of the acoustic and borehole radar data. The report describes the field operation, equipment as well as processing procedures and shows the obtained results and their quality in the appendices. The raw and processed data are delivered digitally in WellCAD and Excel format. (orig.)

  15. Geophysical borehole logging and optical imaging of the boreholes KR34, KR35 and KR36, at Olkiluoto 2005

    International Nuclear Information System (INIS)

    Majapuro, J.

    2005-09-01

    Suomen Malmi Oy conducted geophysical borehole logging and optical imaging surveys of the boreholes KR34, KR35 and KR36 at the Olkiluoto site in Eurajoki during May - June 2005. The survey is a part of Posiva Oy's detailed investigation program for the final disposal of spent nuclear fuel. The methods applied are magnetic susceptibility, natural gamma radiation, gamma-gamma density, single point resistance, Wenner-resistivity, borehole radar, full waveform sonic and optical imaging. The assignment included the field work of all surveys, interpretation and processing of the acoustic and borehole radar data. The report describes the field operation, equipment as well as processing procedures and shows the obtained results and their quality in the appendices. The raw and processed data are delivered digitally in WellCAD and Excel format. (orig.)

  16. Proposal of requirements for performance in Brazil for systems of external individual monitoring for neutrons applying the TLD-albedo technique

    International Nuclear Information System (INIS)

    Martins, Marcelo M.; Mauricio, Claudia L.P.; Pereira, Walsan W.; Fonseca, Evaldo S. da; Silva, Ademir X.

    2009-01-01

    This work presents a criteria and conditions proposal for the regulations in Brazil of individual monitoring systems for neutrons applying the albedo technique with thermoluminescent detectors. Tests are proposed for the characterization performance of the system based on the Regulation ISO 21909 and on the experience of the authors

  17. Monitoring of Individual Needs in Diabetes (MIND)-2 Follow-up data from the cross-national Diabetes Attitudes, Wishes, and Needs (DAWN) MIND study

    NARCIS (Netherlands)

    Snoek, F.J.; Kersch, N.Y.A.; Eldrup, E.; Harman-Boehm, I.; Hermanns, N.; Kokoszka, A.; Matthews, D.R.; McGuire, B.E.; Pibernik-Okanovic, M.; Singer, J.; de Wit, M.; Skovlund, S.E.

    2012-01-01

    OBJECTIVE - To test the effects of implementing computer-assisted Monitoring of Individual Needs in Diabetes (MIND) in routine diabetes care on psychological status and glycemic control, identify predictors of poor psychological outcomes, and evaluate care providers' experiences. RESEARCH DESIGN AND

  18. Completion summary for boreholes USGS 140 and USGS 141 near the Advanced Test Reactor Complex, Idaho National Laboratory, Idaho

    Science.gov (United States)

    Twining, Brian V.; Bartholomay, Roy C.; Hodges, Mary K.V.

    2014-01-01

    In 2013, the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, drilled and constructed boreholes USGS 140 and USGS 141 for stratigraphic framework analyses and long-term groundwater monitoring of the eastern Snake River Plain aquifer at the Idaho National Laboratory in southeast Idaho. Borehole USGS 140 initially was cored to collect continuous geologic data, and then re-drilled to complete construction as a monitor well. Borehole USGS 141 was drilled and constructed as a monitor well without coring. Boreholes USGS 140 and USGS 141 are separated by about 375 feet (ft) and have similar geologic layers and hydrologic characteristics based on geophysical and aquifer test data collected. The final construction for boreholes USGS 140 and USGS 141 required 6-inch (in.) diameter carbon-steel well casing and 5-in. diameter stainless-steel well screen; the screened monitoring interval was completed about 50 ft into the eastern Snake River Plain aquifer, between 496 and 546 ft below land surface (BLS) at both sites. Following construction and data collection, dedicated pumps and water-level access lines were placed to allow for aquifer testing, for collecting periodic water samples, and for measuring water levels. Borehole USGS 140 was cored continuously, starting from land surface to a depth of 543 ft BLS. Excluding surface sediment, recovery of basalt and sediment core at borehole USGS 140 was about 98 and 65 percent, respectively. Based on visual inspection of core and geophysical data, about 32 basalt flows and 4 sediment layers were collected from borehole USGS 140 between 34 and 543 ft BLS. Basalt texture for borehole USGS 140 generally was described as aphanitic, phaneritic, and porphyritic; rubble zones and flow mold structure also were described in recovered core material. Sediment layers, starting near 163 ft BLS, generally were composed of fine-grained sand and silt with a lesser amount of clay; however, between 223 and 228 ft BLS, silt

  19. Thermal modelling of borehole heat exchangers and borehole thermal energy stores; Zur thermischen Modellierung von Erdwaermesonden und Erdsonden-Waermespeichern

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Dan

    2011-07-15

    The thermal use of the underground for heating and cooling applications can be done with borehole heat exchangers. This work deals with the further development of the modelling of thermal transport processes inside and outside the borehole as well as with the application of the further developed models. The combination of high accuracy and short computation time is achieved by the development of three-dimensional thermal resistance and capacity models for borehole heat exchangers. Short transient transport processes can be calculated by the developed model with a considerable higher dynamic and accuracy than with known models from literature. The model is used to evaluate measurement data of a thermal response test by parameter estimation technique with a transient three-dimensional model for the first time. Clear advantages like shortening of the test duration are shown. The developed borehole heat exchanger model is combined with a three-dimensional description of the underground in the Finite-Element-Program FEFLOW. The influence of moving groundwater on borehole heat exchangers and borehole thermal energy stores is then quantified.

  20. KASAM Hearing on the Deep Borehole Concept

    International Nuclear Information System (INIS)

    Hedberg, Bjoern

    2008-01-01

    Bjoern Hedberg from KASAM, Sweden, reported on the organisation's new Transparency Programme on nuclear waste. The first event of this programme, which took place in March 2007, was a hearing on the deep borehole concept (DBH) as a possible alternative method for final disposal. The hearing was triggered by an increasing attention paid to DBH by several stakeholders, including NGOs, municipalities and the media. Issues of technical feasibility, long-term safety and safety philosophy were addressed, among others. The RISCOM-model for transparency was used for structuring the discussions. In this model transparency is achieved through the 'stretching' of various actors, aimed at exploring the facts, values and judgements underlying the arguments. Mr Hedberg indicated that the KASAM hearing has resulted in generating and surfacing of new knowledge related to the technical feasibility of the DBH concept. He observed that although there was a consensus between key actors on basic facts, there were divergent views on their implications. Based on the hearing, Mr Hedberg concluded that at this time the DBH concept cannot be seen as an alternative of the KBS-3 method. To make a final decision, however, more research is needed, for example, on the issue whether the DBH concept supports retrievability. He emphasised that the RISCOM structure proved to be useful since the stretching of actors by KASAM committee members and staff has led to new insights. The effectiveness of the process could be further enhanced by increasing the stretching capacity, i.e. time devoted to the hearing and in-depth preparation, and active participation of KASAM members

  1. The electrical resistivity method in cased boreholes

    Energy Technology Data Exchange (ETDEWEB)

    Schenkel, C.J.

    1991-05-01

    The use of downhole current sources in resistivity mapping can greatly enhance the detection and delineation of subsurface features. The purpose of this work is to examine the resistivity method for current sources in wells cased with steel. The resistivity method in cased boreholes with downhole current sources is investigated using the integral equation (IE) technique. The casing and other bodies are characterized as conductivity inhomogeneities in a half-space. For sources located along the casing axis, an axially symmetric Green's function is used to formulate the surface potential and electric field (E-field) volume integral equations. The situations involving off-axis current sources and three-dimensional (3-D) bodies is formulated using the surface potential IE method. The solution of the 3-D Green's function is presented in cylindrical and Cartesian coordinate systems. The methods of moments is used to solve the Fredholm integral equation of the second kind for the response due to the casing and other bodies. The numerical analysis revealed that the current in the casing can be approximated by its vertical component except near the source and the axial symmetric approximation of the casing is valid even for the 3-D problem. The E-field volume IE method is an effective and efficient technique to simulate the response of the casing in a half-space, whereas the surface potential approach is computationally better when multiple bodies are involved. Analyzing several configurations of the current source indicated that the casing response is influenced by four characteristic factors: conduction length, current source depth,casing depth, and casing length. 85 refs., 133 figs., 11 tabs.

  2. Borehole plugging by hydrothermal transport. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Roy, D.M.; White, W.B.

    1976-02-28

    Calcium silicate--and aluminosilicate--compositions based on mixtures of fine grained quartz with various cements or calcium silicate compounds have been investigated under hydrothermal conditions in the temperature range 110-250/sup 0/C and pressure range 1,000-10,000 psi, pressures which are always in excess of that required to maintain liquid H/sub 2/O, and approximate the confining pressures which might be anticipated in deep boreholes. All silicate cement combinations investigated produce materials having adequate strength after reaction times of 1 day or longer. The calcium aluminate cement was also adequate with respect to strength but would need to be investigated more extensively for overall properties because of its highly reactive chemistry. The mini-rock cylinder-cement plug hydrothermal experiments in both limestone and sandstone resulted in reasonable magnitudes of bonding strength. The typical shear strength of a hydrothermally treated cement-sandstone plug is 1030 psi, and the compressive strength of the extruded cement plug is 9550 psi. Reactions having a potential for producing calcium carbonate plugs in holes drilled in carbonate rocks were studied. It should be noted that most cements are calcium silicate systems and are chemically compatible with the CaCO/sub 3/ and CaMg(CO/sub 3/)/sub 2/ in the rock walls of the hole. A side benefit from this research is some insight into the suitability of massive carbonate rocks as disposal sites. Carbonate rocks by themselves are highly impermeable, have low exchange capacity, and a low water content--all properties that are desirable in the storage medium. A major drawback is the presence of secondary permeability in the form of solutionally modified joints, fractures, and bedding planes.

  3. Borehole plugging by hydrothermal transport. Final report

    International Nuclear Information System (INIS)

    Roy, D.M.; White, W.B.

    1976-01-01

    Calcium silicate--and aluminosilicate--compositions based on mixtures of fine grained quartz with various cements or calcium silicate compounds have been investigated under hydrothermal conditions in the temperature range 110-250 0 C and pressure range 1,000-10,000 psi, pressures which are always in excess of that required to maintain liquid H 2 O, and approximate the confining pressures which might be anticipated in deep boreholes. All silicate cement combinations investigated produce materials having adequate strength after reaction times of 1 day or longer. The calcium aluminate cement was also adequate with respect to strength but would need to be investigated more extensively for overall properties because of its highly reactive chemistry. The mini-rock cylinder-cement plug hydrothermal experiments in both limestone and sandstone resulted in reasonable magnitudes of bonding strength. The typical shear strength of a hydrothermally treated cement-sandstone plug is 1030 psi, and the compressive strength of the extruded cement plug is 9550 psi. Reactions having a potential for producing calcium carbonate plugs in holes drilled in carbonate rocks were studied. It should be noted that most cements are calcium silicate systems and are chemically compatible with the CaCO 3 and CaMg(CO 3 ) 2 in the rock walls of the hole. A side benefit from this research is some insight into the suitability of massive carbonate rocks as disposal sites. Carbonate rocks by themselves are highly impermeable, have low exchange capacity, and a low water content--all properties that are desirable in the storage medium. A major drawback is the presence of secondary permeability in the form of solutionally modified joints, fractures, and bedding planes

  4. Forsmark site characterisation - Borehole KFM22 and KFM23: Derivation of porewater data by diffusion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Waber, H. N. [Rock Water Interaction, University of Bern, Bern (Switzerland); Smellie, J. A. T. [Conterra AB, Partille (Sweden)

    2012-04-15

    Within the Detum Project (Detailed Investigations in Forsmark) a 'Methodology comparison for porewater extraction and characterisation techniques' was initiated. This has centred on two shallow boreholes drilled at Soederviken within the northern part of the Forsmark characterisation site. The comparison includes different methodologies to characterise the chemical and isotopic composition of porewater residing in the connected pore space of the rock matrix. The present report describes the chemical and isotopic information of the porewater obtained by out-diffusion experiments and the diffusive isotope equilibration technique applied to originally water saturated drillcore samples. In addition, petrophysical data and solute transport properties of the rock matrix, all necessary for porewater characterisation, have also been elaborated. Specially conditioned drillcore samples were obtained from depths of less than 100 m from boreholes KFM22 and KFM23. Porewater has been extracted successfully from seven samples by laboratory out-diffusion and diffusive isotope exchange methods. The methodology to extract and analyse the porewater is outlined and the analytical data are tabulated. The data are critically reviewed for potential experimental artefacts and their significance with respect to in situ conditions. The connected pore space in the core material representing borehole KFM22 and KFM23 was measured on different types of originally saturated drillcore samples using gravimetric and isotope mass balance methods. Out-diffusion experiments were performed on kg-sized drillcore samples to derive the in situ concentration of the chemically conservative compounds chloride and bromide. The attainment of equilibrium conditions in the out-diffusion experiments was monitored by the concentration change of chloride and bromide as a function of time. The water isotope composition of porewater was determined by the diffusive isotope equilibration technique and by

  5. Geology of the Waste Treatment Plant Seismic Boreholes

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, D. BRENT; Bjornstad, Bruce N.; Fecht, Karl R.; Lanigan, David C.; Reidel, Steve; Rust, Colleen F.

    2007-02-28

    In 2006, DOE-ORP initiated the Seismic Boreholes Project (SBP) to emplace boreholes at the Waste Treatment Plant (WTP) site in order to obtain direct Vs measurements and other physical property measurements in Columbia River basalt and interbedded sediments of the Ellensburg Formation. The goal was to reduce the uncertainty in the response spectra and seismic design basis, and potentially recover design margin for the WTP. The characterization effort within the deep boreholes included 1) downhole measurements of the velocity properties of the suprabasalt, basalt, and sedimentary interbed sequences, 2) downhole measurements of the density of the subsurface basalt and sediments, and 3) confirmation of the geometry of the contact between the various basalt and interbedded sediments through examination of retrieved core from the corehole and data collected through geophysical logging of each borehole. This report describes the results of the geologic studies from three mud-rotary boreholes and one cored borehole at the WTP. All four boreholes penetrated the entire Saddle Mountains Basalt and the upper part of the Wanapum Basalt where thick sedimentary interbeds occur between the lava flows. The basalt flows penetrated in Saddle Mountains Basalt included the Umatilla Member, Esquatzel Member, Pomona Member and the Elephant Mountain Member. The underlying Priest Rapids Member of the Wanapum Basalt was also penetrated. The Ellensburg Formation sediments consist of the Mabton Interbed, the Cold Creek Interbed, the Selah Interbed and the Rattlesnake Ridge Interbed; the Byron Interbed occurs between two flows of the Priest Rapids Member. The Mabton Interbed marks the contact between the Wanapum and Saddle Mountains Basalts. The thicknesses of the basalts and interbedded sediments were within expected limits. However, a small reverse fault was found in the Pomona Member flow top. This fault has three periods of movement and less than 15 feet of repeated section. Most of the

  6. Novel Emplacement Device for a Very Deep Borehole Disposal

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Soo; Choi, Heui-joo; Lee, Jong Yul [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    There is a worldwide attempt of HLW disposal into a very deep borehole of around 3-5 km depth with the advancement of an underground excavation technology recently. As it goes into deeper underground, the rock becomes more uniform and flawless. And then the underground water circulation system at 3-5 km depth is almost disconnected with near groundwater circulation system. The canister integrity is less important in this very deep borehole disposal system unlike a general geologic disposal system at 500 m. In the deep borehole disposal procedures, one SNF (Spent Nuclear Fuel) assembly is stored in one disposal canister (D30-40cm, H4.7-5.0m), and approximately 10-40 disposal canisters are connected axially, which parade length can leach to around 200m in maximum. The connected canister parade is lowered through a very deep borehole (D40-50cm) by emplacement devices. Therefore the connections between canisters and canister to lowering joint are very important for the safe operation of it. The well-known connection method between canisters is Threaded Coupled Connection method, in which releasing of the connection is almost impossible after thread fastening in the borehole. The novel joint device suggested in this paper can accommodate a canister emplacement and retrieval in the borehole disposal process. The joint can be lowered by bound to a drilling pipe, or high tension cable along 3-5 km distance. This novel device can cope with an accidental event easily without any joint head change. When canisters are damaged or stuck on the borehole wall during their descending, the canisters in trouble can be retrieved simply by the control of a lifting speed.

  7. Fibromyalgia symptom reduction by online behavioral self-monitoring, longitudinal single subject analysis and automated delivery of individualized guidance

    OpenAIRE

    William Collinge; Paul Yarnold; Robert Soltysik

    2013-01-01

    Background: Fibromyalgia (FM) is a complex chronic pain condition that is difficult to treat. The prevailing approach is an integration of pharmacological, psycho-educational, and behavioral strategies. Information technology offers great potential for FM sufferers to systemically monitor symptoms as well as potential impacts of various management strategies. Aims: This study aimed to evaluate effects of a web-based, self-monitoring and symptom management system (SMARTLog) that analyzes perso...

  8. Self-monitoring practices, attitudes, and needs of individuals with bipolar disorder: implications for the design of technologies to manage mental health.

    Science.gov (United States)

    Murnane, Elizabeth L; Cosley, Dan; Chang, Pamara; Guha, Shion; Frank, Ellen; Gay, Geri; Matthews, Mark

    2016-05-01

    To understand self-monitoring strategies used independently of clinical treatment by individuals with bipolar disorder (BD), in order to recommend technology design principles to support mental health management. Participants with BD (N = 552) were recruited through the Depression and Bipolar Support Alliance, the International Bipolar Foundation, and WeSearchTogether.org to complete a survey of closed- and open-ended questions. In this study, we focus on descriptive results and qualitative analyses. Individuals reported primarily self-monitoring items related to their bipolar disorder (mood, sleep, finances, exercise, and social interactions), with an increasing trend towards the use of digital tracking methods observed. Most participants reported having positive experiences with technology-based tracking because it enables self-reflection and agency regarding health management and also enhances lines of communication with treatment teams. Reported challenges stem from poor usability or difficulty interpreting self-tracked data. Two major implications for technology-based self-monitoring emerged from our results. First, technologies can be designed to be more condition-oriented, intuitive, and proactive. Second, more automated forms of digital symptom tracking and intervention are desired, and our results suggest the feasibility of detecting and predicting emotional states from patterns of technology usage. However, we also uncovered tension points, namely that technology designed to support mental health can also be a disruptor. This study provides increased understanding of self-monitoring practices, attitudes, and needs of individuals with bipolar disorder. This knowledge bears implications for clinical researchers and practitioners seeking insight into how individuals independently self-manage their condition as well as for researchers designing monitoring technologies to support mental health management. © The Author 2016. Published by Oxford University

  9. An error-related negativity potential investigation of response monitoring function in individuals with Internet addiction disorder

    Directory of Open Access Journals (Sweden)

    Zhenhe eZhou

    2013-09-01

    Full Text Available Internet addiction disorder (IAD is an impulse disorder or at least related to impulse control disorder. Deficits in executive functioning, including response monitoring, have been proposed as a hallmark feature of impulse control disorders. The error-related negativity (ERN reflects individual’s ability to monitor behavior. Since IAD belongs to a compulsive-impulsive spectrum disorder, theoretically, it should present response monitoring functional deficit characteristics of some disorders, such as substance dependence, ADHD or alcohol abuse, testing with an Erikson flanker task. Up to now, no studies on response monitoring functional deficit in IAD were reported. The purpose of the present study was to examine whether IAD displays response monitoring functional deficit characteristics in a modified Erikson flanker task.23 subjects were recruited as IAD group. 23 matched age, gender and education healthy persons were recruited as control group. All participants completed the modified Erikson flanker task while measured with event-related potentials (ERPs. IAD group made more total error rates than did controls (P < 0.01; Reactive times for total error responses in IAD group were shorter than did controls (P < 0.01. The mean ERN amplitudes of total error response conditions at frontal electrode sites and at central electrode sites of IAD group were reduced compared with control group (all P < 0.01. These results revealed that IAD displays response monitoring functional deficit characteristics and shares ERN characteristics of compulsive-impulsive spectrum disorder.

  10. Understanding of safety monitoring in clinical trials by individuals with CF or their parents: A qualitative analysis.

    Science.gov (United States)

    Kern-Goldberger, Andrew S; Hessels, Amanda J; Saiman, Lisa; Quittell, Lynne M

    2018-03-14

    Recruiting both pediatric and adult participants for clinical trials in CF is currently of paramount importance as numerous new therapies are being developed. However, recruitment is challenging as parents of children with CF and adults with CF cite safety concerns as a principal barrier to enrollment. In conjunction with the CF Foundation (CFF) Data Safety Monitoring Board (DSMB), a pilot brochure was developed to inform patients and parents of the multiple levels of safety monitoring; the CFF simultaneously created an infographic representing the safety monitoring process. This study explores the attitudes and beliefs of CF patients and families regarding safety monitoring and clinical trial participation, and elicits feedback regarding the educational materials. Semi-structured interviews were conducted using a pre-tested interview guide and audio-recorded during routine CF clinic visits. Participants included 5 parents of children with CF quotations: attitudes toward clinical trials, safety values, conceptualizing the safety monitoring process, and priorities for delivery of patient education. Participant feedback was used to revise the pilot brochure; text was shortened, unfamiliar words clarified (e.g., "pipeline"), abbreviations eliminated, and redundancy avoided. Qualitative analysis of CF patient and family interviews provided insights into barriers to participation in clinical trials, safety concerns, perspectives on safety monitoring and educational priorities. We plan a multicenter study to determine if the revised brochure reduces knowledge, attitude and practice barriers regarding participation in CF clinical trials. Copyright © 2018 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  11. Conductive fracture mapping. A study on the correlation between borehole TV- and radar images and difference flow logging results in borehole KLX02

    International Nuclear Information System (INIS)

    Carlsten, S.; Straahle, A.; Ludvigson, Jan-Erik

    2001-10-01

    and conformity of the reference level of each individual method is crucial. Provided that the adjustment of the length scales of the different logging methods does not bias the studied correlation between the logging methods, this study appear to yield promising results with regards to structural-hydrogeological interpretations and models. However, improved depth resolution of the radar measurements is required. Finally, correct length scales of the logging sequences, preferably by using reference depth marks in the boreholes, are crucial for the correlation

  12. Conductive fracture mapping. A study on the correlation between borehole TV- and radar images and difference flow logging results in borehole KLX02

    Energy Technology Data Exchange (ETDEWEB)

    Carlsten, S.; Straahle, A.; Ludvigson, Jan-Erik [GEOSIGMA AB, Uppsala (Sweden)

    2001-10-01

    is at present under development. Also, certainty and conformity of the reference level of each individual method is crucial. Provided that the adjustment of the length scales of the different logging methods does not bias the studied correlation between the logging methods, this study appear to yield promising results with regards to structural-hydrogeological interpretations and models. However, improved depth resolution of the radar measurements is required. Finally, correct length scales of the logging sequences, preferably by using reference depth marks in the boreholes, are crucial for the correlation.

  13. Uemachi flexure zone investigated by borehole database and numeical simulation

    Science.gov (United States)

    Inoue, N.; Kitada, N.; Takemura, K.

    2014-12-01

    The Uemachi fault zone extending north and south, locates in the center of the Osaka City, in Japan. The Uemachi fault is a blind reverse fault and forms the flexure zone. The effects of the Uemachi flexure zone are considered in constructing of lifelines and buildings. In this region, the geomorphological survey is difficult because of the regression of transgression. Many organizations have carried out investigations of fault structures. Various surveys have been conducted, such as seismic reflection survey in and around Osaka. Many borehole data for construction conformations have been collected and the geotechnical borehole database has been constructed. The investigation with several geological borehole data provides the subsurface geological information to the geotechnical borehole database. Various numerical simulations have been carried out to investigate the growth of a blind reverse fault in unconsolidated sediments. The displacement of the basement was given in two ways. One is based on the fault movement, such as dislocation model, the other is a movement of basement block of hanging wall. The Drucker-Prager and elastic model were used for the sediment and basement, respectively. The simulation with low and high angle fault movements, show the good agree with the actual distribution of the marine clay inferred from borehole data in the northern and southern Uemachi fault flexure zone, respectively. This research is partly funded by the Comprehensive Research on the Uemachi Fault Zone (from FY2010 to FY2012) by The Ministry of Education, Culture, Sports, Science and Technology (MEXT).

  14. Deep Borehole Field Test Requirements and Controlled Assumptions.

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Ernest [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-07-01

    This document presents design requirements and controlled assumptions intended for use in the engineering development and testing of: 1) prototype packages for radioactive waste disposal in deep boreholes; 2) a waste package surface handling system; and 3) a subsurface system for emplacing and retrieving packages in deep boreholes. Engineering development and testing is being performed as part of the Deep Borehole Field Test (DBFT; SNL 2014a). This document presents parallel sets of requirements for a waste disposal system and for the DBFT, showing the close relationship. In addition to design, it will also inform planning for drilling, construction, and scientific characterization activities for the DBFT. The information presented here follows typical preparations for engineering design. It includes functional and operating requirements for handling and emplacement/retrieval equipment, waste package design and emplacement requirements, borehole construction requirements, sealing requirements, and performance criteria. Assumptions are included where they could impact engineering design. Design solutions are avoided in the requirements discussion. Deep Borehole Field Test Requirements and Controlled Assumptions July 21, 2015 iv ACKNOWLEDGEMENTS This set of requirements and assumptions has benefited greatly from reviews by Gordon Appel, Geoff Freeze, Kris Kuhlman, Bob MacKinnon, Steve Pye, David Sassani, Dave Sevougian, and Jiann Su.

  15. VHBORE: A code to compute borehole fluid conductivity profiles with pressure changes in the borehole

    International Nuclear Information System (INIS)

    Hale, F.V.; Tsang, C.F.

    1994-06-01

    This report describes the code VHBORE which can be used to model fluid electric conductivity profiles in a borehole intersecting fractured rock under conditions of changing pressure in the well bore. Pressure changes may be due to water level variations caused by pumping or fluid density effects as formation fluid is drawn into the borehole. Previous reports describe the method of estimating the hydrologic behavior of fractured rock using a time series of electric conductivity logs and an earlier code, BORE, to generate electric conductivity logs under constant pressure and flow rate conditions. The earlier model, BORE, assumed a constant flow rate, q i , for each inflow into the well bore. In the present code the user supplies the location, constant pressure, h i , transmissivity, T i , and storativity, S i , for each fracture, as well as the initial water level in the well, h w (0), In addition, the input data contains changes in the water level at later times, Δh w (t), typically caused by turning a pump on or off. The variable density calculation also requires input of the density of each of the inflow fluids, ρ i , and the initial uniform density of the well bore fluid, ρ w (0). These parameters are used to compute the flow rate for each inflow point at each time step. The numerical method of Jacob and Lohman (1952) is used to compute the flow rate into or out of the fractures based on the changes in pressure in the wellbore. A dimensionless function relates flow rate as a function of time in response to an imposed pressure change. The principle of superposition is used to determine the net flow rate from a time series of pressure changes. Additional reading on the relationship between drawdown and flow rate can be found in Earlougher (1977), particularly his Section 4.6, open-quotes Constant-Pressure Flow Testingclose quotes

  16. Palynological characterization of Givetian-Frasnian deposits in the reference Borehole section 1-Balneologicheskaya (Southern Timan)

    Science.gov (United States)

    Tel'Nova, O. P.

    2008-04-01

    A succession of seven palynological assemblages characterizing the Yuzhnyi Timan, Taman, Ust-Yarega, Domanik, and Vetlosyan formations of the southern Timan is established in the Givetian-Frasnian deposits recovered by Borehole 1-Balneologicheskaya and studied in detail. Five individual zones, which are distinguished within stratigraphic range of the optivus-krestovnicovii miospore zone, can be of basic importance for a high-resolution stratigraphic subdivision of the sedimentation stage under consideration. Phytostratigraphic boundary corresponding to the Frasnian Stage base in the East European platform is substantiated in palynological aspect.

  17. An overview of the MIZ-1 borehole investigations during phase I/II. MIZ-1 progress report 03-01

    International Nuclear Information System (INIS)

    Ota, Kunio; Takeuchi, Shinji; Ikeda, Koki

    2004-05-01

    Surface-based investigations have now been carried out, in a step-by-step fashion, with the main aims of the development of conceptual models of the geological environment and the enhancement of the understanding of the undisturbed deep geological environment before excavation of the shafts and experimental drifts. The MIZ-1 borehole investigation programme was launched in December 2002, as a step of the field investigations at the MIU Construction Site. The overall goals of the MIZ-1 borehole investigations are to characterise the geological environment from the surface to over 1,000 m depth in the crystalline basement, to establish baseline conditions before excavation of the shafts and experimental drifts, and to provide a deep borehole for observing hydraulic responses during the shaft and drift excavation and experiments in the drifts during the Construction and the Operation Phases. The borehole is planned to be drilled in an overall south-westerly direction from the north-eastern area of the MIU Site. The planned inclination varies from vertical at shallower depths to 12deg from vertical at greater depths down to 1,350 m along the borehole length, which will be achieved by controlled directional drilling. In MIZ-1 Phase I/II (from March to May 2003), the borehole was drilled vertically, through the entire sedimentary formations, down to 123.00 m in the uppermost part of the Toki granite at the MIU Construction Site. The new method of wireline core drilling with a downhole motor was introduced for the drilling. Planned geological, geophysical and hydrochemical investigations and complementary hydraulic and hydrochemical monitoring were performed. In addition, as a complete loss of drilling fluid was encountered at 115.85 m along the borehole length, modified work procedures resulted in the execution of hydraulic tests with groundwater sampling, from necessity, in that section and of further drilling work. The local QC system was applied to all the

  18. Comparison of non-invasive individual monitoring of the training and health of athletes with commercially available wearable technologies

    Directory of Open Access Journals (Sweden)

    Peter eDüking

    2016-03-01

    Full Text Available Athletes adapt their training daily to optimize performance, as well as avoid fatigue, overtraining and other undesirable effects on their health. To optimize training load, each athlete must take his/her own personal objective and subjective characteristics into consideration and an increasing number of wearable technologies (wearables provide convenient monitoring of various parameters. Accordingly, it is important to help athletes decide which parameters are of primary interest and which wearables can monitor these parameters most effectively. Here, we discuss the wearable technologies available for non-invasive monitoring of various parameters concerning an athlete’s training and health. On the basis of these considerations, we suggest directions for future development. Furthermore, we propose that a combination of several wearables is most effective for accessing all relevant parameters, disturbing the athlete as little as possible, and optimizing performance and promoting health.

  19. Analysis of borehole-radar reflection logs from selected HC boreholes at the Project Shoal area, Churchill County, Nevada; TOPICAL

    International Nuclear Information System (INIS)

    Lane, J.W. Jr.; Joesten, P.K.; Pohll, Greg; Mihevic, Todd

    2001-01-01

    Single-hole borehole-radar reflection logs were collected and interpreted in support of a study to characterize ground-water flow and transport at the Project Shoal Area (PSA) in Churchill County, Nevada. Radar logging was conducted in six boreholes using 60-MHz omni-directional electric-dipole antennas and a 60-MHz magnetic-dipole directional receiving antenna. Radar data from five boreholes were interpreted to identify the location, orientation, estimated length, and spatial continuity of planar reflectors present in the logs. The overall quality of the radar data is marginal and ranges from very poor to good. Twenty-seven reflectors were interpreted from the directional radar reflection logs. Although the range of orientation interpreted for the reflectors is large, a significant number of reflectors strike northeast-southwest and east-west to slightly northwest-southeast. Reflectors are moderate to steeply dipping and reflector length ranged from less than 7 m to more than 133 m. Qualitative scores were assigned to each reflector to provide a sense of the spatial continuity of the reflector and the characteristics of the field data relative to an ideal planar reflector (orientation score). The overall orientation scores are low, which reflects the general data quality, but also indicates that the properties of most reflectors depart from the ideal planar case. The low scores are consistent with reflections from fracture zones that contain numerous, closely spaced, sub-parallel fractures. Interpretation of borehole-radar direct-wave velocity and amplitude logs identified several characteristics of the logged boreholes: (1) low-velocity zones correlate with decreased direct-wave amplitude, indicating the presence of fracture zones; (2) direct-wave amplitude increases with depth in three of the boreholes, suggesting an increase in electrical resistivity with depth resulting from changes in mineral assemblage or from a decrease in the specific conductance of ground

  20. Analysis of borehole-radar reflection logs from selected HC boreholes at the Project Shoal area, Churchill County, Nevada

    Science.gov (United States)

    Lane, J.W.; Joesten, P.K.; Pohll, G.M.; Mihevic, Todd

    2001-01-01

    Single-hole borehole-radar reflection logs were collected and interpreted in support of a study to characterize ground-water flow and transport at the Project Shoal Area (PSA) in Churchill County, Nevada. Radar logging was conducted in six boreholes using 60-MHz omni-directional electric-dipole antennas and a 60-MHz magnetic-dipole directional receiving antenna.Radar data from five boreholes were interpreted to identify the location, orientation, estimated length, and spatial continuity of planar reflectors present in the logs. The overall quality of the radar data is marginal and ranges from very poor to good. Twenty-seven reflectors were interpreted from the directional radar reflection logs. Although the range of orientation interpreted for the reflectors is large, a significant number of reflectors strike northeast-southwest and east-west to slightly northwest-southeast. Reflectors are moderate to steeply dipping and reflector length ranged from less than 7 m to more than 133 m.Qualitative scores were assigned to each reflector to provide a sense of the spatial continuity of the reflector and the characteristics of the field data relative to an ideal planar reflector (orientation score). The overall orientation scores are low, which reflects the general data quality, but also indicates that the properties of most reflectors depart from the ideal planar case. The low scores are consistent with reflections from fracture zones that contain numerous, closely spaced, sub-parallel fractures.Interpretation of borehole-radar direct-wave velocity and amplitude logs identified several characteristics of the logged boreholes: (1) low-velocity zones correlate with decreased direct-wave amplitude, indicating the presence of fracture zones; (2) direct-wave amplitude increases with depth in three of the boreholes, suggesting an increase in electrical resistivity with depth resulting from changes in mineral assemblage or from a decrease in the specific conductance of ground

  1. Completion summary for boreholes TAN-2271 and TAN‑2272 at Test Area North, Idaho National Laboratory, Idaho

    Science.gov (United States)

    Twining, Brian V.; Bartholomay, Roy C.; Hodges, Mary K.V.

    2016-06-30

    In 2015, the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, drilled and constructed boreholes TAN-2271 and TAN-2272 for stratigraphic framework analyses and long-term groundwater monitoring of the eastern Snake River Plain aquifer at the Idaho National Laboratory in southeast Idaho. Borehole TAN-2271 initially was cored to collect continuous geologic data, and then re-drilled to complete construction as a monitor well. Borehole TAN-2272 was partially cored between 210 and 282 feet (ft) below land surface (BLS) then drilled and constructed as a monitor well. Boreholes TAN-2271 and TAN-2272 are separated by about 63 ft and have similar geologic layers and hydrologic characteristics based on geologic, geophysical, and aquifer test data collected. The final construction for boreholes TAN-2271 and TAN-2272 required 10-inch (in.) diameter carbon-steel well casing and 9.9-in. diameter open-hole completion below the casing to total depths of 282 and 287 ft BLS, respectively. Depth to water is measured near 228 ft BLS in both boreholes. Following construction and data collection, temporary submersible pumps and water-level access lines were placed to allow for aquifer testing, for collecting periodic water samples, and for measuring water levels.Borehole TAN-2271 was cored continuously, starting at the first basalt contact (about 33 ft BLS) to a depth of 284 ft BLS. Excluding surface sediment, recovery of basalt and sediment core at borehole TAN-2271 was better than 98 percent. Based on visual inspection of core and geophysical data, material examined from 33 to 211ft BLS primarily consists of two massive basalt flows that are about 78 and 50 ft in thickness and three sediment layers near 122, 197, and 201 ft BLS. Between 211 and 284 ft BLS, geophysical data and core material suggest a high occurrence of fractured and vesicular basalt. For the section of aquifer tested, there are two primary fractured aquifer intervals: the first between 235 and

  2. Sampling and chemical analysis of groundwaters from the exploratory boreholes

    International Nuclear Information System (INIS)

    Wittwer, C.

    1986-10-01

    As a part of the Nagra geological investigation programme in northern Switzerland, numerous water samples were taken in the Boettstein, Weiach, Riniken, Schafisheim, Kaisten and Leuggern boreholes to obtain information on the chemistry and residence times of deep groundwaters. This report contains a compilation of hydrochemical data, comments on the individual water sampling actions and an evaluation of sample quality with respect to admixing of drilling fluids. The samples were taken from separate test intervals in the sediments and the crystalline rock. After removal of various types of drilling fluids such as mud as well as fresh water or deionised water during a cleaning phase, the samples were taken at the surface or at depth using pressure vessels. The tracers added to the drilling fluids (uranine, m-TFMBA) as well as the tritium content were used for a quantiative estimation of the content of drilling fluid in the samples (contamination). With a view fo further geochemical modelling, the samples were assessed with reference to the effect of contamination on the results of the chemical analyses. A total of 68 water samples were taken from 53 different intervals: - 27 samples had problem-free cleaning phases and were taken with negligible contamination. - 23 samples were taken under difficult conditions. Problems with hydraulic communication around packers, uncertain origin, inaccuracy as to extent of contamination, presence of cement, possible traces of salt from drilling fluid etc. meant that the analyses could only be used with extreme caution or after additional data-processing. - The analysis results from 18 samples will be disregarded due to significant drilling fluid content or because more reliable data are available for the same test interval. (author)

  3. Exploratory borehole Schafisheim: constructional- and environmental aspects, drilling technique

    International Nuclear Information System (INIS)

    1991-04-01

    The Schafisheim borehole was the fourth borehole in the Nagra deep drilling programme in Northern Switzerland. The drilling work began on the 26th of November 1983. The final depth of 2000.6 m was reached on June 29th, 1984 and this was followed by a transition to a test phase which lasted until 25th February 1985. To reach the final depth, the borehole passed through around 1500 m of sediments and 500 m of crystalline rock. More than 50% of the drilled section, including more or less all of the crystalline rock, was cored. This report describes the drilling activities, the construction work relating to the Schafisheim site and the measures taken to ensure environmental protection. The report closes with a chapter dealing with the supervisory commission consisting of members of the federal, cantonal and local authorities and with the report series on the drilling work. (author) figs., tabs

  4. Electrical resistivity borehole measurements: application to an urban tunnel site

    Science.gov (United States)

    Denis, A.; Marache, A.; Obellianne, T.; Breysse, D.

    2002-06-01

    This paper shows how it is possible to use wells drilled during geotechnical pre-investigation of a tunneling site to obtain a 2-D image of the resistivity close to a tunnel boring machine. An experimental apparatus is presented which makes it possible to perform single and borehole-to-borehole electrical measurements independent of the geological and hydrogeological context, which can be activated at any moment during the building of the tunnel. This apparatus is first demonstrated through its use on a test site. Numerical simulations and data inversion are used to analyse the experimental results. Finally, electrical resistivity tomography and single-borehole measurements on a tunneling site are presented. Experimental results show the viability of the apparatus and the efficiency of the inverse algorithm, and also highlight the limitations of the electrical resistivity tomography as a tool for geotechnical investigation in urban areas.

  5. Geophysical borehole logging. Final disposal of spent fuel

    International Nuclear Information System (INIS)

    Rouhiainen, P.

    1984-01-01

    Teollisuuden Voima Oy (Industrial Power Company Ltd.) will take precautions for final disposal of spent fuel in the Finnish bedrock. The first stage of the site selection studies includes drilling of a deep borehole down to approximately 1000 meters in the year 1984. The report deals with geophysical borehole logging methods, which could be used for the studies. The aim of geophysical borehole logging methods is to descripe specially hydrogeological and structural features. Only the most essential methods are dealt with in this report. Attention is paid to the information produced with the methods, derscription of the methods, interpretation and limitations. The feasibility and possibilities for the aims are evaluated. The evaluations are based mainly on the results from Sweden, England, Canada and USA as well as experiencies gained in Finland

  6. Savage Island Project borehole completion report

    International Nuclear Information System (INIS)

    Chamness, M.A.; Gilmore, T.J.; Teel, S.S.

    1993-02-01

    This report discusses three wells which were drilled in 1990 and 1991 in support of Pacific Northwest Laboratory's Ground-Water surveillance Project. These wells were intended to monitor the Rattlesnake Ridge interbed aquifer and the deeper portion of the unconfined aquifer to determine whether ground-water contamination emanating from the Hanford Site was migrating offsite through these aquifers. This report discusses well construction, lithologies encountered, and other data collected during drilling. At least three reports have been or are being prepared to discuss the results of this well monitoring project

  7. Summary of the Lavia borehole investications in 1984

    International Nuclear Information System (INIS)

    Aeikaes, T.; Oehberg, A.; Ryhaenen, V.

    1985-02-01

    Industrial Power Company Ltd (TVO) drilled in the spring 1984 a 1001 m deep borehole, diameter 56 mm, in Lavia. The borehole is used during the years 1984-85 for developing and testing research methods and equipment needed in site investigations of spent fuel final disposal in the future. In 1984 hydraulical and geophysical tests were made and groundwater samples were taken. The drilling site is a wide outcropped area in the northern part of the porphyritic granite formation of Lavia. Geological and fracture mapping as well as geophysical measurements on the surface were made in the area surrounding the drilling site. The bedrock consists of homonous porphyritic granite, in which quartzdiorite occurs in thin incalations. Magnetic or electric anomalies were not observed. Fracture frequency is low and the fractures appear mainly in two sets. The rock types vary in the borehole from porphyritic granite to diorite. Due to slight mineralogical variations, the diorite is either granodiorite, quartzdiorite or tonalite. Granite occurs as veins. Hydraulic conductivity was measured systematically with a packer separation of 30 m between the depths 73-973 m. Hydraulic conductivity is generally 10 -10 -10 -11 m/s. Electric, radiometric, magnetic and acoustic measurements were made in the borehole. In addition, the caliper and the temperature of the borehole were measured. The results of these geophysical measurements indicate the properties of rock types and fracturing in the borehole. On the basis of the results e.g. fracture porosity was interpreted. The results of acoustic tube wave measurement correlate well with hydraulic conductivity. Water samples were taken from four depths. The deepest level was 910 m. The samples were taken with a packer separation of 5 m. In the water analyses it was observed that at several depths remarkable amounts of flushing water from drilling were still remaining in the rock

  8. Deep borehole disposal of high-level radioactive waste.

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua S.; Freeze, Geoffrey A.; Brady, Patrick Vane; Swift, Peter N.; Rechard, Robert Paul; Arnold, Bill Walter; Kanney, Joseph F.; Bauer, Stephen J.

    2009-07-01

    Preliminary evaluation of deep borehole disposal of high-level radioactive waste and spent nuclear fuel indicates the potential for excellent long-term safety performance at costs competitive with mined repositories. Significant fluid flow through basement rock is prevented, in part, by low permeabilities, poorly connected transport pathways, and overburden self-sealing. Deep fluids also resist vertical movement because they are density stratified. Thermal hydrologic calculations estimate the thermal pulse from emplaced waste to be small (less than 20 C at 10 meters from the borehole, for less than a few hundred years), and to result in maximum total vertical fluid movement of {approx}100 m. Reducing conditions will sharply limit solubilities of most dose-critical radionuclides at depth, and high ionic strengths of deep fluids will prevent colloidal transport. For the bounding analysis of this report, waste is envisioned to be emplaced as fuel assemblies stacked inside drill casing that are lowered, and emplaced using off-the-shelf oilfield and geothermal drilling techniques, into the lower 1-2 km portion of a vertical borehole {approx}45 cm in diameter and 3-5 km deep, followed by borehole sealing. Deep borehole disposal of radioactive waste in the United States would require modifications to the Nuclear Waste Policy Act and to applicable regulatory standards for long-term performance set by the US Environmental Protection Agency (40 CFR part 191) and US Nuclear Regulatory Commission (10 CFR part 60). The performance analysis described here is based on the assumption that long-term standards for deep borehole disposal would be identical in the key regards to those prescribed for existing repositories (40 CFR part 197 and 10 CFR part 63).

  9. Outline of the 1996-1998 IAEA co-ordinated research project on intercomparison for individual monitoring of external exposure from photon radiation

    International Nuclear Information System (INIS)

    Boehm, J.; Gustafsson, M.; Ouvrard, R.

    1999-01-01

    The outline of the IAEA Co-ordinated Research Project 1996-1998 on intercomparison for individual monitoring is described. The intercomparison focused on IAEA Member States in Eastern Europe and was based on the operational quantity personal dose equivalent, H p (10). The three phases of the intercomparison were: the preparatory phase including a workshop, the 'type-test' intercomparison, and the 'simulated workplace field' intercomparison. Details of the phases are given. (author)

  10. Enhancement of Self-Monitoring in a Web-Based Weight Loss Program by Extra Individualized Feedback and Reminders: Randomized Trial.

    Science.gov (United States)

    Hutchesson, Melinda Jane; Tan, Chor Yin; Morgan, Philip; Callister, Robin; Collins, Clare

    2016-04-12

    Self-monitoring is an essential behavioral strategy for effective weight loss programs. Traditionally, self-monitoring has been achieved using paper-based records. However, technology is now more frequently used to deliver treatment programs to overweight and obese adults. Information technologies, such as the Internet and mobile phones, allow innovative intervention features to be incorporated into treatment that may facilitate greater adherence to self-monitoring processes, provide motivation for behavior change, and ultimately lead to greater weight loss success. The objective of our study was to determine whether the consistency of self-monitoring differed between participants randomly assigned to a basic or an enhanced 12-week commercial Web-based weight loss program. We randomly assigned a sample of 301 adults (mean age 42.3 years; body mass index 31.3 kg/m2; female 176/301, 58.5%) to the basic or enhanced group. The basic program included tools for self-monitoring (online food and exercise diary, and a weekly weigh-in log) with some feedback and reminders to weigh in (by text or email). The enhanced program included the basic components, as well as extra individualized feedback on self-monitoring entries and reminders (by text, email, or telephone) to engage with self-monitoring tools. We evaluated the level of self-monitoring by examining the consistency of self-monitoring of food, exercise, and weight during the 12 weeks. Consistency was defined as the number of weeks during which participants completed a criterion number of entries (ie, ≥3 days of online food or exercise diary records per week and ≥1 weigh-in per week). The enhanced group's consistency of use of self-monitoring tools was significantly greater than that of the basic group throughout the 12 weeks (median consistency for food 8 vs 3 weeks, respectively, Pself-monitoring behaviors in a Web-based weight loss program. Australian New Zealand Clinical Trials Registry (ANZCTR): ACTRN

  11. Background subtraction system for pulsed neutron logging of earth boreholes

    International Nuclear Information System (INIS)

    Hertzog, R.C.

    1983-01-01

    The invention provides a method for determining the characteristics of earth formations surrounding a well borehole comprising the steps of: repetitively irradiating the earth formations surrounding the well bore with relatively short duration pulses of high energy neutrons; detecting during each pulse of high energy neutrons, gamma radiation due to the inelastic scattering of neutrons by materials comprising the earth formations surrounding the borehole and providing information representative thereof; detecting immediately following each such pulse of high energy neutrons, background gamma radiation due to thermal neutron capture and providing information representative thereof; and correcting the inelastic gamma representative information to compensate for said background representative information

  12. Model of the final borehole geometry for helical laser drilling

    Science.gov (United States)

    Kroschel, Alexander; Michalowski, Andreas; Graf, Thomas

    2018-05-01

    A model for predicting the borehole geometry for laser drilling is presented based on the calculation of a surface of constant absorbed fluence. It is applicable to helical drilling of through-holes with ultrashort laser pulses. The threshold fluence describing the borehole surface is fitted for best agreement with experimental data in the form of cross-sections of through-holes of different shapes and sizes in stainless steel samples. The fitted value is similar to ablation threshold fluence values reported for laser ablation models.

  13. Method for detecting cement voids or borehole washouts

    International Nuclear Information System (INIS)

    Smith, M.P.

    1978-01-01

    A fast neutron source is used to irradiate earth formations in the vicinity of a well borehole. Dual spaced epithermal neutron detectors are used to sample the epithermal neutron population at two different spaced distances from the source. A compensated formation porosity is obtained from the ratio of counting rates at the dual spaced detectors. An uncompensated porosity value is obtained from the count rate at the short spaced detector. Borehole washout or cement void regions are located by comparing the compensated and uncompensated values of formation porosity obtained in this manner

  14. Individualized monitoring of drug bioavailability and immunogenicity in rheumatoid arthritis patients treated with the tumor necrosis factor alpha inhibitor infliximab

    DEFF Research Database (Denmark)

    Bendtzen, Klaus; Geborek, Pierre; Svenson, Morten

    2006-01-01

    Infliximab, an anti-tumor necrosis factor alpha (anti-TNFalpha) antibody, is effective in the treatment of several immunoinflammatory diseases. However, many patients experience primary or secondary response failure, suggesting that individualization of treatment regimens may be beneficial...

  15. Location Capability and Site Characterization Installing a Borehole VBB Seismometer: the OGS Experience in Ferrara (Italy)

    Science.gov (United States)

    Pesaresi, D.; Barnaba, C.

    2014-12-01

    The Centro di Ricerche Sismologiche (CRS, Seismological Research Centre) of the Istituto Nazionale di Oceanografia e di Geofisica Sperimentale (OGS, Italian National Institute for Oceanography and Experimental Geophysics) in Udine (Italy) after the strong earthquake of magnitude M=6.4 occurred in 1976 in the Italian Friuli-Venezia Giulia region, started to operate the Northeastern Italy Seismic Network: it currently consists of 19 very sensitive broad band and 17 simpler short period seismic stations, all telemetered to and acquired in real time at the OGS CRS data centre in Udine. The southwestern edge of the OGS seismic network stands on the Po alluvial basin: earthquake localization and characterization in this area is affected by the presence of soft alluvial deposits. Following the ML=5.9 earthquake that struck the Emilia region around Ferrara in Northern Italy on May 20, 2012, a cooperation of Istituto Nazionale di Geofisica e Vulcanologia, OGS, the Comune di Ferrara and the University of Ferrara lead to the reinstallation of a previously existing very broad band (VBB) borehole seismic station in Ferrara and to the deployment of a temporary seismographic network consisting of eight portable seismological stations, to record the local earthquakes that occurred during the seismic sequence. The aim of the OGS intervention was on one hand to extend its real time seismic monitoring capabilities toward South-West, including Ferrara and its surroundings, and on the other hand to evaluate seismic site responses in the area. We will introduce details of the Ferrara VBB borehole station and the OGS temporary seismographic network configuration and installation. We will then illustrate the location capability performances, and finally we will shortly describe seismic site characterization with surface/borehole comparisons in terms of seismic noise, site amplification and resonance frequencies.

  16. Geophysical borehole logging of the boreholes KR23 extension, KR29 and KR29b at Olkiluoto 2004

    International Nuclear Information System (INIS)

    Lahti, M.; Heikkinen, E.

    2005-04-01

    Suomen Malmi Oy conducted geophysical borehole logging of the boreholes KR23 extension, KR25b, KR29 and KR29b at the Olkiluoto site in Eurajoki during October 2004. The survey is a part of Posiva Oy's detailed investigation program for the final disposal of spent nuclear fuel. The assignment included the field work and processing of the acoustic data. The report describes the field operation, equipment as well as processing procedures and shows the obtained results and their quality in the appendices. The raw and processed data are delivered digitally in WellCAD and Excel format. (orig.)

  17. Geophysical borehole logging of the boreholes KR23 extension, KR29 and KR29b at Olkiluoto 2004

    Energy Technology Data Exchange (ETDEWEB)

    Lahti, M. [Suomen Malmi Oy, Espoo (Finland); Heikkinen, E. [JP-Fintact Oy, Vantaa (Finland)

    2005-04-15

    Suomen Malmi Oy conducted geophysical borehole logging of the boreholes KR23 extension, KR25b, KR29 and KR29b at the Olkiluoto site in Eurajoki during October 2004. The survey is a part of Posiva Oy's detailed investigation program for the final disposal of spent nuclear fuel. The assignment included the field work and processing of the acoustic data. The report describes the field operation, equipment as well as processing procedures and shows the obtained results and their quality in the appendices. The raw and processed data are delivered digitally in WellCAD and Excel format. (orig.)

  18. Geophysical borehole logging of the boreholes KR37, KR37B and KR38, at Olkiluoto 2005

    International Nuclear Information System (INIS)

    Majapuro, J.

    2006-03-01

    Suomen Malmi Oy conducted geophysical borehole logging of the boreholes KR37, KR37b and KR38 at the Olkiluoto site in Eurajoki during September and October 2005. The survey is a part of Posiva Oy's detailed investigation program for the final disposal of spent nuclear fuel. The assignment included the field work and processing of the acoustic data. The report describes the field operation, equipment as well as processing procedures and shows the obtained results and their quality in the appendices. The raw and processed data are delivered digitally in WellCAD and Excel format. (orig.)

  19. The 1996-2009 borehole dilatometer installations, operation, and maintenance at sites in Long Valley Caldera, CA

    Science.gov (United States)

    Myren, Glenn; Johnston, Malcolm; Mueller, Robert

    2011-01-01

    High seismicity levels with accelerating uplift (under the resurgent dome) in Long Valley caldera in the eastern Sierra Nevada from 1989 to 1997, triggered upgrades to dilational strainmeters and other instrumentation installed in the early 1980's following a series of magnitude 6 earthquakes. This included two additional high-resolution borehole strainmeters and replacement of the failed strainmeter at Devil's Postpile. The purpose of the borehole-monitoring network is to monitor crustal deformation and other geophysical parameters associated with volcanic intrusions and earthquakes in the Long Valley Caldera. Additional instrumentation was added at these sites to improve the capability of providing continuous monitoring of the magma source under the resurgent dome. Sites were selected in regions of hard crystalline rock, where the expected signals from magmatic activity were calculated to be a maximum and the probability of an earthquake of magnitude 4 or greater is large. For the most part, the dilatometers were installed near existing arrays of surface tiltmeters, seismometers, level line, and GPS arrays. At each site, attempts are made to separate tectonic and volcanic signals from known noise sources in each instrument type. Each of these sites was planned to be a multi-parameter monitoring site, which included measurements of 3-component seismic velocity and acceleration, borehole strain, tilt, pore pressure and magnetic field. Using seismicity, geophysical knowledge, geologic and topographic maps, and geologists recommendations, lists of preliminary sites were chosen. Additional requirements were access, and telemetry constraints. When the final site choice was made, a permit was obtained from the U.S. Forest Service. Following this selection process, two new borehole sites were installed on the north and south side of the Long Valley Caldera in June of 1999. One site was located near Big Spring Campground to the east of Crestview. The second site was

  20. Comparison of dynamic monitoring strategies based on CD4 cell counts in virally suppressed, HIV-positive individuals on combination antiretroviral therapy in high-income countries: a prospective, observational study

    NARCIS (Netherlands)

    Caniglia, Ellen C.; Cain, Lauren E.; Sabin, Caroline A.; Robins, James M.; Logan, Roger; Abgrall, Sophie; Mugavero, Michael J.; Hernández-Díaz, Sonia; Meyer, Laurence; Seng, Remonie; Drozd, Daniel R.; Seage, George R.; Bonnet, Fabrice; Dabis, Francois; Moore, Richard D.; Reiss, Peter; van Sighem, Ard; Mathews, William C.; del Amo, Julia; Moreno, Santiago; Deeks, Steven G.; Muga, Roberto; Boswell, Stephen L.; Ferrer, Elena; Eron, Joseph J.; Napravnik, Sonia; Jose, Sophie; Phillips, Andrew; Justice, Amy C.; Tate, Janet P.; Gill, John; Pacheco, Antonio; Veloso, Valdilea G.; Bucher, Heiner C.; Egger, Matthias; Furrer, Hansjakob; Porter, Kholoud; Touloumi, Giota; Crane, Heidi; Miro, Jose M.; Sterne, Jonathan A.; Costagliola, Dominique; Saag, Michael; Hernán, Miguel A.

    2017-01-01

    Clinical guidelines vary with respect to the optimal monitoring frequency of HIV-positive individuals. We compared dynamic monitoring strategies based on time-varying CD4 cell counts in virologically suppressed HIV-positive individuals. In this observational study, we used data from prospective

  1. Intercomparison for individual monitoring of external exposure from photon radiation. Results of a co-ordinated research project 1996-1998

    International Nuclear Information System (INIS)

    1999-12-01

    This TECDOC presents the results of a Co-ordinated Research Project on Intercomparison for Individual Monitoring of External Exposure from photon radiation. The International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS) have endorsed the use of the operational quantities for monitoring purposes. Specifically, personal dose equivalent, H p (d), is to be used for individual dosimetry to demonstrate compliance with the exposure limit recommendations, while for workplace area monitoring the ambient dose equivalent and the directional dose equivalent are recommended. In view of the technical difficulties associated with the introduction of these operational quantities the IAEA decided to assist Member States in their provision of appropriate dosimetry for occupational protection. In this respect, intercomparisons have proven to be a cost effective method of providing such support. A Co-ordinated Research Project (CRP) was started in 1997 on Intercomparison for Individual Monitoring of External Exposure from photon radiation, involving more than twenty laboratories from eastern Europe and the countries of the former Soviet Union, and focusing on personnel dosimetry services for nuclear power plants. This CRP was part of the activities of the IAEA Occupational Protection Programme, the objective4s of which are to promote and internationally harmonized approach for optimizing occupational radiation protection through: the development of guides, within the IAEA activities for establishing standards for radiation protection, for restricting radiation exposures in the workplace and for applying current occupational radiation protection techniques, and the promotion of the application of these guidelines. The preparatory phase included, in May 1997, a workshop aimed at familiarizing the participants with the new operational quantities

  2. Development of in vitro bioanalysis technique for individual monitoring of {sup 32}P; Desenvolvimento de técnicas de bioanálise in vitro para monitoração individual de {sup 32}P

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Ana Paula F. de; Dantas, Bernardo M.; Sousa, Wanderson O., E-mail: bmdantas@ird.gov.br [Instituto de Radioproteção e Dosimetria /Divisão de Dosimetria, Rio de Janeiro-RJ (Brazil)

    2017-07-01

    {sup 32}P is usually handled in the form of liquid unsealed sources in medical facilities, in research and teaching institutions, and in industrial radiopharmaceutical production plants. Such practices represent a risk of internal exposure in routine activities and in case of accidents. The estimation of {sup 32}P incorporation can be accomplished through in vitro bioassay. This paper presents a methodology to analyze {sup 32}P in biological samples, applicable to internal individual monitoring using liquid scintillation technique. Based on the experimental results it is possible to conclude that the technique presents enough sensitivity to detect activities that result in committed effective dose in the order of 1 mSv. (author)

  3. Development of a geophysical methodology from boreholes for the study of granitic formation storage site

    International Nuclear Information System (INIS)

    Le Masne, D.

    1983-01-01

    The aim of this work is the characterization of the fracturation of a granitic formation by the examination of borehole environment. Two types of methods are used. Methods using one borehole only: well logging (electrical and nuclear). Didier logs (electric dipole-dipole), Eric probes (electromagnetic dipole-dipole) and methods between boreholes (grounding). These methods were applied to two boreholes of 500m and 1000 meters drilled into granite at Auriat (France)

  4. Concentration of Trace Metals in Boreholes in the Ankobra Basin ...

    African Journals Online (AJOL)

    Fiifi Baidoo

    Most of the boreholes with high trace metal concentrations were located in and around the Bawdie-Bogoso-Prestea area. Introduction. Ankobra basin is one of the main mining areas in Ghana. The major minerals mined in this area include gold, manganese, bauxite and diamond. Gold mining in this basin dates about 500 ...

  5. Development of a mobile borehole investigation software using augmented reality

    Science.gov (United States)

    Son, J.; Lee, S.; Oh, M.; Yun, D. E.; Kim, S.; Park, H. D.

    2015-12-01

    Augmented reality (AR) is one of the most developing technologies in smartphone and IT areas. While various applications have been developed using the AR, there are a few geological applications which adopt its advantages. In this study, a smartphone application to manage boreholes using AR has been developed. The application is consisted of three major modules, an AR module, a map module and a data management module. The AR module calculates the orientation of the device and displays nearby boreholes distributed in three dimensions using the orientation. This module shows the boreholes in a transparent layer on a live camera screen so the user can find and understand the overall characteristics of the underground geology. The map module displays the boreholes on a 2D map to show their distribution and the location of the user. The database module uses SQLite library which has proper characteristics for mobile platforms, and Binary XML is adopted to enable containing additional customized data. The application is able to provide underground information in an intuitive and refined forms and to decrease time and general equipment required for geological field investigations.

  6. Bacteriological analysis of borehole water in Uli, Nigeria | Ibe ...

    African Journals Online (AJOL)

    The highest counts were consistently found in the sample from Cagramento Lodge, where the borehole was located in an unsanitary environment, near a pit laterine. Escherichia coli, Klebsiella sp., Proteus sp., Enterobacter sp., Pseudomonas sp., and Staphylococcus aureus were isolated from the samples. The findings ...

  7. Preliminary report on geophysical and mechanical borehole measurements at Stripa

    International Nuclear Information System (INIS)

    Nelson, P.; Paulsson, B.; Rachiele, R.; Andersson, L.; Schrauf, T.; Hustrulid, W.; Duran, O.; Magnusson, K.A.

    1979-05-01

    A suite of seven logs--neutron, gamma--gamma, resistivity, gamma ray, sonic, caliper, and temperature--operated in a borehole of 380-m depth located eleven zones where the rock permeability is expected to be enhanced due to the presence of open fractures. The sonic waveform record proved especially useful in this regard. Borehole measurements were also acquired in a large number of boreholes from 5- to 14-m length located in experimental drifts some 340-m underground. Here several physical properties, including the porosity, density, sonic velocity, and borehole rugosity, are generally quite uniform, with the exception of a few local chloritic zones and a few minor fractures. However, in situ determinations of the mechanical modulus with the CSM cell indicate substantial variability, with some apparent fracture control. Uranium and thorium concentrations are quite high in the Stripa granite, with local fluctuations associated with mineralogical changes as revealed by the gamma-ray log. A differential resistance probe appears promising as a sensitive detector of fine fracturing. A cross-hole ultrasonic system indicates variations of a few percent in compressional- and shear-wave velocities, reflecting the presence of fractures and changes in fracture characteristics as the rock is heated in a simulated storage test. The geophysical and mechanical data are being compared with the results from core and television logging, with hydrological test data on static pressure and injection permeability, and with displacements induced by thermal loading

  8. Rock-welding materials for deep borehole nuclear waste disposal.

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Pin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wang, Yifeng [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rodriguez, Mark A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brady, Patrick Vane [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Swift, Peter N. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-11-01

    The concept of deep borehole nuclear waste disposal has recently been proposed. Effective sealing of a borehole after waste emplacement is generally required. In a high temperature disposal mode, the sealing function will be fulfilled by melting the ambient granitic rock with waste decay heat or an external heating source, creating a melt that will encapsulate waste containers or plug a portion of the borehole above a stack of the containers. However, there are certain drawbacks associated with natural materials, such as high melting temperatures, slow crystallization kinetics, the resulting sealing materials generally being porous with low mechanical strength, insufficient adhesion to waste container surface, and lack of flexibility for engineering controls. Here we show that natural granitic materials can be purposefully engineered through chemical modifications to enhance the sealing capability of the materials for deep borehole disposal. This work systematically explores the effect of chemical modification and crystallinity (amorphous vs. crystalline) on the melting and crystallization processes of a granitic rock system. A number of engineered granitic materials have been obtained that have decreased melting points, enhanced viscous densification, and accelerated recrystallization rates without compromising the mechanical integrity of the materials.

  9. Shock-induced borehole waves and fracture effects

    NARCIS (Netherlands)

    Fan, H.; Smeulders, D.M.J.

    2012-01-01

    We perform wave experiments using a vertical shock tube setup. Shock waves are generated by the rupture of a thin membrane. In the test section the incident pressure waves generate borehole-guided waves along water-saturated samples. The tube is equipped with side wall gages and a mobile pressure

  10. physicochemical quality of borehole water in abonnema and its ...

    African Journals Online (AJOL)

    PROF. BARTH EKWEME

    AND ITS PUBLIC HEALTH IMPORTANCE. GLORIA N. ... + 0.4, while conductivity values for Briggs and Obonoma compounds were 47.8 and 50.6 µs/cm respectively. However, the study ... boreholes, boiling and filtering of drinking water as well as improved sanitary conditions and personal hygiene were advocated.

  11. Determination of subsurface geological structure with borehole gravimetry

    International Nuclear Information System (INIS)

    Clark, S.R.; Hearst, J.R.

    1983-07-01

    Conventional gamma-gamma and gravimetric density measurements are routinely gathered for most holes used for underground nuclear tests. The logs serve to determine the subsurface structural geology near the borehole. The gamma-gamma density log measures density of the rock within about 15 cm of the borehole wall. The difference in gravity measured at two depths in a borehole can be interpreted in terms of the density of an infinite, homogeneous, horizontal bed between those depths. When the gravimetric density matches the gamma-gamma density over a given interval it is assumed that the bed actualy exists, and that rocks far from the hole must be the same as those encountered adjacent to the borehole. Conversely, when the gravimetric density differs from the gamma-gamma density it is apparent that the gravimeter is being influenced by a rock mass of different density than that at the hole wall. This mismatch can be a powerful tool to deduce the local structural geology. The geology deduced from gravity mesurements in emplacement hole, U4al, and the associated exploratory hole, UE4al, is an excellent example of the power of the method

  12. Development of a stress gauge for borehole using photoelasticity

    International Nuclear Information System (INIS)

    Massal, P.; Caye, R.; Recan, M.

    1986-01-01

    In the framework of the research and development program on storage and disposal in geologic formation stresses in boreholes are measured by overcoring. The principle is stress release by coring around the rock where determinations are carried out. The aim of the present work is the realisation in laboratory of a gauge model based on this principle and measuring deformations by photoelasticity

  13. Application of Ge/Li/-spectrometry in boreholes

    International Nuclear Information System (INIS)

    Chrusciel, E.

    1976-01-01

    The paper presents the results of Ge/Li/ spectrometry applications in boreholes. The natural radioactivity measurements as well as rare elements determinations with the use of 252 Cf neutron source and capture-gamma and activation techniques are described. The minimum concentrations of certain elements to be determined in the field circumstances are evaluated on the basis of the model experiments. (author)

  14. Hydrofracturing water boreholes in hard rock aquifers in Scotland

    CSIR Research Space (South Africa)

    Cobbing, J

    2007-01-01

    Full Text Available rural areas of the UK, low-productivity aquifers are an important resource for small public water supplies. Where a borehole in low-productivity crystalline rocks proves too low yielding for its designed purpose, hydrofracturing is a cost-effective means...

  15. 30 CFR 75.1315 - Boreholes for explosives.

    Science.gov (United States)

    2010-07-01

    .... (e) When blasting slab rounds off the solid, opener holes shall not be drilled beyond the rib line... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Explosives and Blasting § 75.1315 Boreholes for...; and (2) Shots fired in anthracite mines for battery starting or for blasting coal overhangs. No person...

  16. Hydrogeological investigations in two boreholes in the Stripa test station

    International Nuclear Information System (INIS)

    Hansson, K.; Almen, K.-E.; Ekman, L.

    1978-01-01

    The investigations included the following: water injection tests in a horizontal core-borehole, Dbh 2; hydrostatic pressure tests in Dbh2; determination of permeability in a vertical core-borehole, Dbh VI. The results of the water injection tests gave very little information due to the fact, that an air cushion was trapped in the borehole. The hydrostatic pressure tests in Dbh 2 were made in that part of the borehole, which is situated beyond the drift (45 - 97 m). Most of the pressure curves were difficult to interpret. The hydrostatic pressure in the section 89 - 97 m (end of the hole) was calculated to 1,67 Mpa. Near the end of the drift (46.00 - 49.71 m) the pressure was 0.22 Mpa. The permeability tests in Dbh VI were performed by measuring the water-flow and hydrostatic pressure in different levels. The calculated average permeability was 6.5x10 -10 m/s

  17. Geology of the Waste Treatment Plant Seismic Boreholes

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, D. Brent; Fecht, Karl R.; Reidel, Stephen P.; Bjornstad, Bruce N.; Lanigan, David C.; Rust, Colleen F.

    2007-05-11

    In 2006, the U.S. Department of Energy initiated the Seismic Boreholes Project (SBP) to emplace boreholes at the Waste Treatment Plant (WTP) site in order to obtain direct shear wave velocity (Vs) measurements and other physical property measurements in Columbia River basalt and interbedded sediments of the Ellensburg Formation. The goal was to reduce the uncertainty in the response spectra and seismic design basis, and potentially recover design margin for the WTP. The characterization effort within the deep boreholes included 1) downhole measurements of the velocity properties of the suprabasalt, basalt, and sedimentary interbed sequences, 2) downhole measurements of the density of the subsurface basalt and sediments, and 3) geologic studies to confirm the geometry of the contact between the various basalt and interbedded sediments through examination of retrieved core from the core hole and data collected through geophysical logging of each borehole. This report describes the results of the geologic studies from three mud-rotary boreholes and one cored borehole at the WTP. All four boreholes penetrated the entire Saddle Mountains Basalt and the upper part of the Wanapum Basalt where thick sedimentary interbeds occur between the lava flows. The basalt flows penetrated in Saddle Mountains Basalt included the Umatilla Member, Esquatzel Member, Pomona Member, and the Elephant Mountain Member. The underlying Priest Rapids Member of the Wanapum Basalt also was penetrated. The Ellensburg Formation sediments consist of the Mabton Interbed, the Cold Creek Interbed, the Selah Interbed, and the Rattlesnake Ridge Interbed; the Byron Interbed occurs between two flows of the Priest Rapids Member. The Mabton Interbed marks the contact between the Wanapum and Saddle Mountains Basalts. The thicknesses of the basalts and interbedded sediments were within expected limits. However, a small reverse fault was found in the Pomona Member flow top. This fault has three periods of

  18. Sealing of investigation boreholes, Phase 4 - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Pusch, Roland [Drawrite AB, Luleaa Technical University, Luleaa (Sweden); Ramqvist, Gunnar [El-Tekno AB, Figeholm (Sweden); Bockgaard, Niclas [Golder Associates, Goeteborg (Sweden); Ekman, Lennart [LE Geokonsult AB, Baelinge (Sweden)

    2011-09-15

    The report describes the outcome of Phase 4 of the project 'Sealing of investigation boreholes', which deals with 1) characterization and planning of borehole sealing, 2) performance and quality assessment, 3) sealing of large diameter holes, and 4) interaction of clay and concrete plugs. A specific goal was to find ways to characterize, plan and seal of boreholes so that their impact on the overall hydraulic performance of the repository rock can predicted and controlled. The work comprised selection of representative 'reference holes' at the Laxemar and Forsmark sites for development of a general programme for planning and simulating implementation of borehole plugging campaigns, considering also cost issues. A second aim was to define and quantify the role of seals in the reference holes for finding out how important sealing really is. A third was to test a practical way to seal large diameter boreholes and a fourth to find out how concrete matures and performs in contact with smectite clay. The study demonstrated, in conclusion, the need for developing techniques for preparing deep boreholes before lasting seals are installed in them, since poor sealing can short-circuit hydraulically important fracture zones intersected by the holes. The practically oriented sealing activities showed that the technique developed for tight sealing of large-diameter boreholes is practical and feasible. The issue of chemical stability was investigated by testing the performance and constitution of a plug consisting of CBI concrete in contact with smectite-rich seals for almost three years. This study showed that none of them underwent substantial degradation in this period of time, but chemical reactions and thereby generated changes in physical behaviour of the plug components had taken place, particularly in the clay. The rate of degradation is, however, not yet known. It was concluded from this study that it is suitable to carry out a corresponding

  19. Sealing of investigation boreholes, Phase 4 - Final report

    International Nuclear Information System (INIS)

    Pusch, Roland; Ramqvist, Gunnar; Bockgaard, Niclas; Ekman, Lennart

    2011-09-01

    The report describes the outcome of Phase 4 of the project 'Sealing of investigation boreholes', which deals with 1) characterization and planning of borehole sealing, 2) performance and quality assessment, 3) sealing of large diameter holes, and 4) interaction of clay and concrete plugs. A specific goal was to find ways to characterize, plan and seal of boreholes so that their impact on the overall hydraulic performance of the repository rock can predicted and controlled. The work comprised selection of representative 'reference holes' at the Laxemar and Forsmark sites for development of a general programme for planning and simulating implementation of borehole plugging campaigns, considering also cost issues. A second aim was to define and quantify the role of seals in the reference holes for finding out how important sealing really is. A third was to test a practical way to seal large diameter boreholes and a fourth to find out how concrete matures and performs in contact with smectite clay. The study demonstrated, in conclusion, the need for developing techniques for preparing deep boreholes before lasting seals are installed in them, since poor sealing can short-circuit hydraulically important fracture zones intersected by the holes. The practically oriented sealing activities showed that the technique developed for tight sealing of large-diameter boreholes is practical and feasible. The issue of chemical stability was investigated by testing the performance and constitution of a plug consisting of CBI concrete in contact with smectite-rich seals for almost three years. This study showed that none of them underwent substantial degradation in this period of time, but chemical reactions and thereby generated changes in physical behaviour of the plug components had taken place, particularly in the clay. The rate of degradation is, however, not yet known. It was concluded from this study that it is suitable to carry out a corresponding investigation of the plugs

  20. Current state in the research on electronic monitoring systems for the security and flow of objects and individuals

    Directory of Open Access Journals (Sweden)

    Man Dietrich Marcela

    2017-01-01

    Full Text Available This paper sets forth the current state of security systems in prisons from Romania and around the world, particularly aiming electronic systems of monitoring the flow of people, materials control and perimeter security, focusing on the research results concluded by motion detection tests and devices. The currently used systems were observed in order to put an analysis of the methodology together and implement and perfect these systems in protected areas. The protection of citizens must be performed to the extent that is allowed by the legislation.

  1. Characterization of Gas Transport Properties of Fractured Rocks By Borehole and Chamber Tests.

    Science.gov (United States)

    Shimo, M.; Shimaya, S.; Maejima, T.

    2014-12-01

    Gas transport characteristics of fractured rocks is a great concern to variety of engineering applications such as underground storage of LPG, nuclear waste disposal, CCS and gas flooding in the oil field. Besides absolute permeability, relative permeability and capillary pressure as a function of water saturation have direct influences to the results of two phase flow simulation. However, number of the reported gas flow tests for fractured rocks are limited, therefore, the applicability of the conventional two-phase flow functions used for porous media, such as Mualem-van Genuchten model, to prediction of the gas transport in the fractured rock mass are not well understood. The authors conducted the two types of in-situ tests, with different scales, a borehole gas-injection test and a chamber gas-injection test in fractured granitic rock. These tests were conducted in the Cretaceous granitic rocks at the Namikata underground LPG storage cavern construction site in Ehime Prefecture in Japan, preceding to the cavern scale gas-tightness test. A borehole injection test was conducted using vertical and sub-vertical boreholes drilled from the water injection tunnel nearly at the depth of the top of the cavern, EL-150m. A new type downhole gas injection equipment that is capable to create a small 'cavern' within a borehole was developed. After performing a series of preliminary tests to investigate the hydraulic conductivity and gas-tightness, i.e. threshold pressure, gas injection tests were conducted under different gas pressure. Fig.1 shows an example of the test results From a chamber test using a air pressurizing chamber with volume of approximately166m3, the gas-tightness was confirmed within the uncertainty of 22Pa under the storage pressure of 0.7MPa, however, significant air leakage occurred possibly through an open fracture intersecting the chamber just after cavern pressure exceeds the initial hydrostatic pressure at the ceiling level of the chamber. Anomalies

  2. Determination of correction factors for borehole natural gamma-ray measurements by Monte Carlo simulations

    NARCIS (Netherlands)

    Maucec, M.; Hendriks, Peter; Limburg, J.; de Meijer, R. J.

    2009-01-01

    The analysis of natural gamma-ray spectra measured in boreholes has to take into account borehole parameters such as the presence of casings and borehole diameter. For large, high-efficiency gamma-ray detectors, such as BGO-based systems, which employ full-spectrum data analysis, corresponding

  3. 30 CFR 57.22241 - Advance face boreholes (I-C mines).

    Science.gov (United States)

    2010-07-01

    ...) Boreholes shall be drilled in such a manner to insure that the advancing face will not accidently break into... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Advance face boreholes (I-C mines). 57.22241... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22241 Advance face boreholes (I-C mines...

  4. Interpretation of the tracer testing conducted in the Leuggern borehole

    International Nuclear Information System (INIS)

    McNeish, J.A.; Andrews, R.W.; Vomvoris, S.

    1990-12-01

    Tracer testing was conducted in the Leuggern borehole from July to December 1988 to evaluate the hydraulic properties of the crystalline host rock. The tested interval was an approximately 50 m section of fractured crystalline rock at a depth of greater than 1,600 m. The testing consisted of three tracer injection/recovery periods (uranin - 44 days, eosin - 30 days, and naphtionat -14 days), which utilized tracer injection/circulation rates, ranging between 25 and 50 ml/min. During these testing periods, tracer was injected in either of two 1/4 flow lines ported at the top or bottom of the interval and recovered from the other. Following the three tracer injection periods, a natural outflow tracer recovery test was conducted from the central tubing at an average outflow of 12 l/min. The central tubing was ported near the center of the test interval. Data collected during the testing periods included: continuous monitoring of fluid temperature, injection pressure, and electrical conductivity as well as discrete measurement of flow rates, electrical conductivity, fluid temperature, and tracer concentration. Testing results indicate a downward vertical flow of approximately 195-225 ml/min in the isolated interval, from an upper fracture inflow zone to a lower fracture outflow zone. Through analysis of the dilution levels of uranin and eosin during the injection/recovery periods, and review of field data, the top of the upper inflow zone was determined to be approximately 13 m below the top flow line and the bottom of the outflow zone to be approximately 3 to 5 meters above the bottom flow line. The calculated transmissivity value of 6E-05 m 2 /s from observed outflow rate and pressure recovery data, is consistent with results derived from previous hydraulic packer testing in the interval. The effective porosity was determined to be 0.1. Dispersion coefficient values ranged from 1.0 m to 5.0 m. The lateral hydraulic gradient value calculated from tracer recovery

  5. Climate reconstruction from borehole temperatures influenced by groundwater flow

    Science.gov (United States)

    Kurylyk, B.; Irvine, D. J.; Tang, W.; Carey, S. K.; Ferguson, G. A. G.; Beltrami, H.; Bense, V.; McKenzie, J. M.; Taniguchi, M.

    2017-12-01

    Borehole climatology offers advantages over other climate reconstruction methods because further calibration steps are not required and heat is a ubiquitous subsurface property that can be measured from terrestrial boreholes. The basic theory underlying borehole climatology is that past surface air temperature signals are reflected in the ground surface temperature history and archived in subsurface temperature-depth profiles. High frequency surface temperature signals are attenuated in the shallow subsurface, whereas low frequency signals can be propagated to great depths. A limitation of analytical techniques to reconstruct climate signals from temperature profiles is that they generally require that heat flow be limited to conduction. Advection due to groundwater flow can thermally `contaminate' boreholes and result in temperature profiles being rejected for regional climate reconstructions. Although groundwater flow and climate change can result in contrasting or superimposed thermal disturbances, groundwater flow will not typically remove climate change signals in a subsurface thermal profile. Thus, climate reconstruction is still possible in the presence of groundwater flow if heat advection is accommodated in the conceptual and mathematical models. In this study, we derive a new analytical solution for reconstructing surface temperature history from borehole thermal profiles influenced by vertical groundwater flow. The boundary condition for the solution is composed of any number of sequential `ramps', i.e. periods with linear warming or cooling rates, during the instrumented and pre-observational periods. The boundary condition generation and analytical temperature modeling is conducted in a simple computer program. The method is applied to reconstruct climate in Winnipeg, Canada and Tokyo, Japan using temperature profiles recorded in hydrogeologically active environments. The results demonstrate that thermal disturbances due to groundwater flow and climate

  6. Vertical Strain Measured in the Mississippi River Delta Using Borehole Optical Fiber Strainmeters

    Science.gov (United States)

    Hatfield, W.; Allison, M. A.; Bridgeman, J.; Dixon, T. H.; Elliott, D.; Steckler, M. S.; Tornqvist, T. E.; Williams, K.; Wyatt, F. K.; Zumberge, M. A.

    2017-12-01

    Three boreholes in the Mississippi River Delta, at a site 2 km from the river near Myrtle Grove, Louisiana, have been instrumented with optical fiber strainmeters. The boreholes extend to depths of 9 m, 24 m, and 37 m. Each contains an optical fiber strainmeter that records the displacement between a steel surface casing and a termination fixture cemented into the bottom of each borehole. The strainmeters consist of an optical fiber cable stretched to a length 0.2% longer than its unstressed condition. An optical interferometer is formed between each sensing fiber and a second optical fiber of equal length wrapped on a reference mandrel housed in a sonde in the wellhead casing. This arrangement relaxes stability requirements on the light source. A signal processing unit samples the interference fringe signals 50,000 times per second and calculates the optical phase shift, providing a displacement record precise to a few nm or strain sensitivity of better than 1 nanostrain. The sensors operate from solar power and transmit the data (decimated to 20 samples per second) to an archiving system via a cell phone modem. To mitigate against the effects of temperature variations, a second optical fiber sensor with a different temperature is operated in parallel with the first, sharing the same cable and processing sonde. Records from the two fibers allow the separation of optical length changes caused by temperature from the earth strain. The three individual systems provide an unprecedented measure of soil compaction. Over short periods we observe sub-micron signals such as teleseisms, and over the long term we have observed stability at the tenths of a mm level. The site has shown no compaction or subsidence greater than a few tenths of a mm over the last year, highlighting the value of strainmeters over other techniques that can not resolve such small signals. Two of the sensors began operating in July of 2016, the third began operation in May of 2017.

  7. Borehole plugging experiment in OL-KR24 at Olkiluoto, Finland

    International Nuclear Information System (INIS)

    Rautio, T.

    2006-04-01

    Sealing of investigation boreholes has been studied by Svensk Koernbroenslehantering AB (SKB) and Posiva Oy (Posiva) as a part of final disposal research. The proposed principle is that investigation boreholes drilled at a site must not act as a continuous flow path for groundwater but be sealed to become as tight as the surrounding rock. As a part of the investigations SKB and Posiva started the third phase of the joint project 'Cleaning and sealing of investigation boreholes' in 2005. One of the sub-projects was the plugging experiment in borehole OL-KR24 at Olkiluoto. The aim of the experiment was to test all main procedures of borehole sealing concept in practise in a deep borehole. Borehole KR24 was drilled to the depth of 551.11 metres in 2003 and it was located inside the shaft profile in Onkalo. From the surface to the depth of about 120 m the borehole diameter is 98 mm. The rest of the borehole is 75.7 mm in diameter. The borehole is vertical and the inclination is quite accurately 90 degrees. The plugging experiment in borehole OL-KR24 consisted of four main activities: (1) cleaning of the borehole, (2) characterization of the borehole (3) selective stabilisation of the borehole, and (4) emplacement of plugs. The comprehensive cleaning of the borehole was to be done in the first stage to provide the basis for other activities. The aim of characterization was to study the borehole in order to determine the sections for selective stabilisation and the locations for plugs. The characterization phase consisted of caliper measurements, dummy probing and optical borehole imaging (OBI). The aim of selective stabilisation was to show that selected borehole sections can be stabilised using new techniques and methods. One borehole section was reamed from Ω 76 mm to Ω 98 mm. The reamed borehole section should have been filled with sufficient amount of cement-based material to achieve a stable 'concrete tube' after redrilling, but due to encountered problems and

  8. Hand book on the use of TLD badge based on CaSO4:Dy teflon TLD discs for individual monitoring

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Adtani, M.M.; Varadharajan, G.; Bakshi, A.K.; Srivastava, Kshama; Bihari, R.R.

    2002-10-01

    Individual monitoring is one of the most important aspects of a radiation protection programme. In India, an official and centralized personnel monitoring service to radiation workers started in 1952. With the indigenous development of a TLD badge system in 1975 at Bhabha Atomic Research Centre, decentralization of monitoring service was initiated. At present, about 40,000 radiation workers are monitored using this system through twelve TLD units located in different parts of the country, including a private accredited laboratory. Regulatory and other inspecting bodies have often asked outstation TLD units to produce a duly approved document on the procedures being practiced for the assessment of personal doses. A need for such a document has also been felt to ensure the uniformity in processing of dosemeters, recording and reporting of doses by different TLD units and to provide guidelines regarding the infrastructure requirement. This document in the form of a handbook has been prepared to cater to the above needs. The handbook is expected to provide necessary guidelines not only to the newcomers/ forthcoming units and the existing laboratories but also to help the regulators, inspectors and assessors. (author)

  9. Study of borehole probing methods to improve the ground characterization

    Science.gov (United States)

    Naeimipour, Ali

    Collecting geological information allows for optimizing ground control measures in underground structures. This includes understanding of the joints and discontinuities and rock strength to develop rock mass classifications. An ideal approach to collect such information is through correlating the drilling data from the roofbolters to assess rock strength and void location and properties. The current instrumented roofbolters are capable of providing some information on these properties but not fully developed for accurate ground characterization. To enhance existing systems additional instrumentation and testing was conducted in laboratory and field conditions. However, to define the geology along the boreholes, the use of probing was deemed to be most efficient approach for locating joints and structures in the ground and evaluation of rock strength. Therefore, this research focuses on selection and evaluation of proper borehole probes that can offer a reliable assessment of rock mass structure and rock strength. In particular, attention was paid to borehole televiewer to characterize rock mass structures and joints and development of mechanical rock scratcher for determination of rock strength. Rock bolt boreholes are commonly drilled in the ribs and the roof of underground environments. They are often small (about 1.5 inches) and short (mostly 2-3 meter). Most of them are oriented upward and thus, mostly dry or perhaps wet but not filled with water. No suitable system is available for probing in such conditions to identify the voids/joints and specifically to measure rock strength for evaluation of rock mass and related optimization of ground support design. A preliminary scan of available borehole probes proved that the best options for evaluation of rock structure is through analysis of borehole images, captured by optical televiewers. Laboratory and field trials with showed that these systems can be used to facilitate measurement of the location, frequency and

  10. Interpretation of the results from individual monitoring of workers at the Nuclear Fuel Fabrication Facility, Brazil; Interpretacao de resultados de monitoracao individual interna da Fabrica de Combustivel Nuclear - FCN

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Marcelo Xavier de

    2005-07-01

    In nuclear fuel fabrication facilities, workers are exposed to different compounds of enriched uranium. Although in this kind of facility the main route of intake is inhalation, ingestion may occur in some situations, and also a mixture of both. The interpretation of the bioassay data is very complex, since it is necessary taking into account all the different parameters, which is a big challenge. Due to the high cost of the individual monitoring programme for internal dose assessment in the routine monitoring programmes, usually only one type of measurement is assigned. In complex situations like the one described in this study, where several parameters can compromise the accuracy of the bioassay interpretation it is need to have a combination of techniques to evaluate the internal dose. According to ICRP 78 (1997), the general order of preference of measurement methodologies in terms of accuracy of interpretation is: body activity measurement, excreta analysis and personal air sampling. Results of monitoring of working environment may provide information that assists in the interpretation on particle size, chemical form, solubility and date of intake. A group of fifteen workers from controlled area of the studied nuclear fuel fabrication facility was selected to evaluate the internal dose using all different available techniques during a certain period. The workers were monitored for determination of uranium content in the daily urinary and faecal excretion (collected over a period of 3 consecutive days), chest counting and personal air sampling. The results have shown that at least two types of sensitivity techniques must be used, since there are some sources of uncertainties on the bioassay interpretation, like mixture of uranium compounds intake and different routes of intake. The combination of urine and faeces analysis has shown to be the more appropriate methodology for assessing internal dose in this situation. The chest counting methodology has not shown

  11. Detection of buried pipes by polarimetric borehole radar; Polarimetric borehole radar ni yoru maisetsukan no kenshutsu jikken

    Energy Technology Data Exchange (ETDEWEB)

    Sato, M.; Niitsuma, H. [Tohoku University, Sendai (Japan); Nakauchi, T. [Osaka Gas Co. Ltd., Osaka (Japan)

    1997-05-27

    If the borehole radar is utilized for detection of buried pipes, the underground radar measurement becomes possible even in the situation where the mesurement on the earth surface is difficult, for example, such a place as under the road where there is much traffic. However, since buried pipes are horizontally installed and the existing borehole radar can send/receive only vertical polarization, the measurement conducted comes to be poor in efficiency from a viewpoint of the polarization utilization. Therefore, by introducing the polarimetric borehole radar to the detection of buried pipes, a basic experiment was conducted for the effective detection of horizontal buried pipes. Proposing the use of a slot antenna which can send/receive horizontal polarization in borehole in addition to a dipole antenna which sends/receives vertical polarization, developed was a step frequency type continuous wave radar of a network analyzer basis. As a result of the experiment, it was confirmed that reflection from buried pipes is largely dependent on polarization. Especially, it was found that in the slot dipole cross polarization mesurement, reflection from buried pipes can be emphasized. 4 refs., 5 figs.

  12. Production of beta-gamma coincidence spectra of individual radioxenon isotopes for improved analysis of nuclear explosion monitoring data

    Science.gov (United States)

    Haas, Derek Anderson

    Radioactive xenon gas is a fission product released in the detonation of nuclear devices that can be detected in atmospheric samples far from the detonation site. In order to improve the capabilities of radioxenon detection systems, this work produces beta-gamma coincidence spectra of individual isotopes of radioxenon. Previous methods of radioxenon production consisted of the removal of mixed isotope samples of radioxenon gas released from fission of contained fissile materials such as 235U. In order to produce individual samples of the gas, isotopically enriched stable xenon gas is irradiated with neutrons. The detection of the individual isotopes is also modeled using Monte Carlo simulations to produce spectra. The experiment shows that samples of 131mXe, 133 Xe, and 135Xe with a purity greater than 99% can be produced, and that a sample of 133mXe can be produced with a relatively low amount of 133Xe background. These spectra are compared to models and used as essential library data for the Spectral Deconvolution Analysis Tool (SDAT) to analyze atmospheric samples of radioxenon for evidence of nuclear events.

  13. Study for correction of neutron scattering in the calibration of the albedo individual monitor from the Neutron Laboratory (LN), IRD/CNEN-RJ, Brazil

    International Nuclear Information System (INIS)

    Freitas, B.M.; Silva, A.X. da

    2014-01-01

    The Instituto de Radioprotecao e Dosimetria (IRD) runs a neutron individual monitoring service with albedo type monitor and thermoluminescent detectors (TLD). Moreover the largest number of workers exposed to neutrons in Brazil is exposed to 241 Am-Be fields. Therefore a study of the response of albedo dosemeter due to neutron scattering from 241 Am-Be source is important for a proper calibration. In this work, it has been evaluated the influence of the scattering correction in two distances at the Low Scattering Laboratory of the Neutron Laboratory of the Brazilian National Laboratory (Lab. Nacional de Metrologia Brasileira de Radiacoes Ionizantes) in the calibration of that albedo dosemeter for a 241 Am-Be source. (author)

  14. Type test of the Rados MTS-N thermoluminescent dosimetry system for individual monitoring of whole body photons in HP (10)

    International Nuclear Information System (INIS)

    Ferreira, M.S.; Silva, E.R. da; Maurício, C.L.P.

    2017-01-01

    The Institute of Radioprotection and Dosimetry (IRD/CNEN-RJ), uses an automatic thermoluminescent dosimetry (TL) system for evaluation of whole body for photons with individual monitors RADOS MTS-N, with TLF detector of LiF: Mg, Ti. The objective of this work was to characterize this system for the evaluation of H P (10) operating magnitude. The measuring range is 0.2 mSv to 2 Sv, for photon energies from 20 keV to 1250 keV. Performance tests were done for the following characteristics: homogeneity of the monitors, system reproducibility, linearity, temperature and humidity effect, energy and angular dependence and fading. The acceptance requirements used to test system performance have been drawn from national and international documents. The results obtained prove that the system can be used to measure the occupational dose of photons in H P (10)

  15. Results of the 1999. Intercomparison of Individual Monitoring Systems under the IAEA Model Project RLA/9/030

    International Nuclear Information System (INIS)

    Da Silva, Teogenes

    2000-01-01

    In this report the results of the second phase of the intercomparison program within the framework of the IAEA model project RLA/9/030 are presented. In this second phase the objective was to evaluate the performance in terms of the quantity personal dose equivalent, Hp (10) for x and gamma radiation in the energy range form 20 KeV to 1.25 MeV. The main purpose of phase II should be the verification of the quality and reliability of the personnel monitoring system of each participating country. The Centro de Desenvolvimento da Tecnologia Nuclear was the reference laboratory that verified the performance of the participant laboratories. The following countries were invited to participate in the 1999 intercomparison: Bolivia, Colombia, Costa Rica, Dominican Republic, el Salvador, Guatemala, Jamaica, Nicaragua, Panama and Paraguay

  16. The State of Stress Beyond the Borehole

    Science.gov (United States)

    Johnson, P. A.; Coblentz, D. D.; Maceira, M.; Delorey, A. A.; Guyer, R. A.

    2015-12-01

    The state of stress controls all in-situ reservoir activities and yet we lack the quantitative means to measure it. This problem is important in light of the fact that the subsurface provides more than 80 percent of the energy used in the United States and serves as a reservoir for geological carbon sequestration, used fuel disposition, and nuclear waste storage. Adaptive control of subsurface fractures and fluid flow is a crosscutting challenge being addressed by the new Department of Energy SubTER Initiative that has the potential to transform subsurface energy production and waste storage strategies. Our methodology to address the above mentioned matter is based on a novel Advance Multi-Physics Tomographic (AMT) approach for determining the state of stress, thereby facilitating our ability to monitor and control subsurface geomechanical processes. We developed the AMT algorithm for deriving state-of-stress from integrated density and seismic velocity models and demonstrate the feasibility by applying the AMT approach to synthetic data sets to assess accuracy and resolution of the method as a function of the quality and type of geophysical data. With this method we can produce regional- to basin-scale maps of the background state of stress and identify regions where stresses are changing. Our approach is based on our major advances in the joint inversion of gravity and seismic data to obtain the elastic properties for the subsurface; and coupling afterwards the output from this joint-inversion with theoretical model such that strain (and subsequently) stress can be computed. Ultimate