WorldWideScience

Sample records for indium-111 labeled platelets

  1. Indium-111 tropolone, a new tracer for platelet labeling

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Rao, S.A.; Rosemark, J.A.; Chowdhury, S.; Didisheim, P.

    1982-01-01

    Platelets have been labeled with a new neutral, lipid-soluble metal complex of indium 111 ( 111 In) and tropolone. Unlike oxine, which is soluble in ethyl alcohol, tropolone is soluble in isotonic saline. Platelet labeling with 111 In tropolone can be performed in both acid-citrate-dextrose (ACD) plasma and ACD saline within two hours. Labeling efficiency has been 80% to 90%. 111 In tropolone in ACD saline and ACD plasma at tropolone concentrations of 5 and 10 micrograms/ml, respectively, and incubation of the platelets with the tracer at room temperature for 20 minutes were optimal conditions for labeling. The authors have developed an ACD-saline kit for convenient preparation of 111 In-labeled platelets. No adverse effect of 111 In tropolone on platelets has been observed in studies of biodistribution, recovery, and survival of platelets in rabbits and dogs

  2. Indium-111 tropolone, a new tracer for platelet labeling

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Rao, S.A.; Rosemark, J.A.; Chowdhury, S.; Didisheim, P.

    1982-01-01

    Platelets have been labeled with a new neutral, lipid-soluble metal complex of indium 111 ( 111 In) and tropolone. Unlike oxine, which is soluble in ethyl alcohol, tropolone is soluble in isotonic saline. Platelet labeling with 111 In tropolone can be performed in both acid-citrate-dextrose (ACD) plasma and ACD saline within two hours. Labeling efficiency has been 80% to 90%. 111 In tropolone in ACD saline and ACD plasma at tropolone concentrations of 5 to 10 μg/ml, respectively, and incubation of the platelets with the tracer at room temperature for 20 minutes were optimal conditions for labeling. The authors have developed an ACD-saline kit for convenient preparation of 111 In-labeled platelets. No adverse effect of 111 In tropolone on platelets has been observed in studies of biodistribution, recovery, and survival of platelets in rabbits and dogs

  3. Kinetic study of indium-111 labelled platelets in idiopathic thrombocytopenic purpura

    International Nuclear Information System (INIS)

    Reiffers, J.; Vuillemin, L.; Broustet, A.; Ducassou, D.

    1982-01-01

    Labelling platelets with 111 Indium-oxine has advantages over the conventional 51 chromium method: labelling is more efficient and the radiations emitted almost exclusively consist of gamma-rays. Owing to these advantages, autologous platelets can be used for kinetic studies in patients with idiopathic thrombocytopenic purpura, even when thrombocytopenia is severe. 111 Indium labelling also provides accurate information on the sites of platelet destruction, which may help to predict the patient's response to splenectomy [fr

  4. Scintigraphic detection of carotid atherosclerosis with indium-111-labeled autologous platelets

    International Nuclear Information System (INIS)

    Davis, H.H.; Siegel, B.A.; Sherman, L.A.; Heaton, W.A.; Naidich, T.P.; Joist, J.R.; Welch, M.J.

    1980-01-01

    Using autologous platelets labeled with indium-111-oxine, we studied the localization of platelets on arterial lesions by radionuclide scintigraphy in 34 patients with suspected cerebrovascular disease. The imaging results were compared with the findings of contrast angiography in 23 patients, 16 of whom were receiving antiplatelet and/or anticoagulant drugs during the platelet imaging study. Angiography demonstrated atherosclerotic lesions at 33 sites in the extracranial arteries of 16 of these patients. There was accumulation of 111 In-platelets at 20 of these sites (61%) and at three other sites without definite angiographic abnormalities. Lesions with stenoses 111 In-labeled autologous platelets may be useful for evaluating the pathophysiologic characteristics of atherosclerotic lesions in patients with cerebrovascular disease

  5. Indium-111 tropolone, a new high-affinity platelet label: preparation and evaluation of labeling parameters

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Rao, S.A.; Didisheim, P.

    1981-01-01

    Platelets were isolated with a new neutral, lipid-soluble metal complex of indium-111 and tropolone. Unlike oxine, which must be dissolved in ethyl alcohol, tropolone is soluble saline. Platelet labeling with In-111 tropolone can be performed in both acid-citrate-dextrose (ACD)-plasma and ACD-saline media within two hours' time. Labeling efficiency has been 80-90% in ACD-saline and 60-70% in the ACD-plasma medium. Optimum concentrations for the labeling of platelets with In-111 tropolone were 5 micrograms/ml in ACD-saline and 10 micrograms/ml in ACD-plasma, using a 15-min incubation at room temperature. A kit formulation for convenient routine preparation of In-111-labeled platelets has been developed. Seven parameters of platelet labeling were studied: concentration of tropolone, citrate, plasma proteins, and calcium ions; also platelet density, temperature, and pH of incubation medium. Their effects on the mechanism of platelet labeling with lipid-soluble tracers are discussed

  6. Preparation of a viable population of indium-111-labelled human blood platelets

    International Nuclear Information System (INIS)

    Heyns, A.; Badenhorst, P.N.; Pieters, H.; Loetter, M.G.; Minnaar, P.C.; Duyvene de Wit, L.J.; Reenen, O.R. van; Retief, F.P.; University of the Orange Free State, Bloemfontein; University of the Orange Free State, Bloemfontein; University of the Orange Free State, Bloemfontein

    1980-01-01

    Factors influencing labelling of human platelets with 111 Indium-8-hydroxyquinoline ([ 111 In]-oxine) in a physiological saline medium were investigated. The efficiency of labelling is influenced by time of incubation, concentration of oxine, and pH of the incubating medium. It was found that a viable platelet population could be labelled under the following conditions: (1) centrifugation of platelet rich plasma in polystyrene conical tubes at 800 g for 15 min; (2) resuspension of the platelet pellet in saline, pH 5.5; (3) incubating for 30 min at 22 0 C with [ 111 In]-oxine at a concentration of 6.25 mg oxine/litre platelet suspension; (4) washing once with platelet poor autologous plasma (PPP); and (5) finally suspending the platelets in PPP. The labelled platelets aggregated normally with collagen and ADP. Electron microscopy, done immediately after labelling, showed internal organelle reorganization characteristic of activated platelets. These ultrastructural features were reversible on incubationin PPP at 37 0 C for 30 min. The 111 In is not released from aggregated platelets and the label does not elute from incubated platelets for at least five hr. We conclude that human platelets thus labelled are suitable for in vivo kinetic studies. (orig.) [de

  7. Modified method for labeling human platelets with indium-111 oxine using albumin density-gradient separation

    International Nuclear Information System (INIS)

    Bunting, R.W.; Callahan, R.J.; Finkelstein, S.; Lees, R.S.; Strauss, H.W.

    1982-01-01

    When labeling platelets with indium-111 oxine, albumin density-gradient separation minimizes the time spent to resuspend those platelets that have been centrifuged against a hard surface. Labeling efficiency or platelet viability, as measured by platelet survival or aggregation with adenosine diphosphate, are not adversely affected

  8. Indium-111-oxine labeled platelet kinetics in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Forstrom, L.A.; Luikens, B.; Johnson, T.

    1984-01-01

    The possible role of abnormal platelet function in the pathogenesis of vascular disease in patients with diabetes mellitus remains controversial. In vitro studies have shown variable alterations in platelet function in such patients. Studies of in vivo platelet kinetics in diabetic patients have been inconclusive, although decreased platelet survival has been observed in some cases. Earlier studies were carried out using chromium-51 or selenium-75 for platelet labeling. The authors have performed Indium-111-oxine labeled platelet kinetic and biodistribution studies in 4 patients with diabetes mellitus (ages 49-61 years), and in 4 control subjects (ages 46-60 years). All subjects were male. All diabetic patients were poorly controlled at the time of study, with blood glucose > 140 mg% and hemoglobin A-1c > 10%. Autologous platelets were labeled with Indium-111-oxine in ACD:plasma by previously reported methods, and reinjected in a dose of approximately 50 μCi (range 42-67μCi). Average recovery of the injected platelets was 67% (range 41-85%). Computer analyzed images at 24 hours showed no significant difference in liver uptake between diabetic and control subjects. Mildly increased splenic uptake in diabetic patients was of borderline significance (p=.07). Platelet survival was slightly decreased in diabetic subjects by 3 of 4 models utilized (linear, exponential, multiple hit and weighted mean), although the difference achieved significance only for the weighted man model (p=.05). These data support observations by earlier methods which suggest that platelet survival may be decreased in patients with diabetes mellitus

  9. Indium-111 labelled platelets: experimental and clinical studies

    International Nuclear Information System (INIS)

    Gjerloeff Schmidt, K.

    1985-10-01

    The object of the present study became to develop a method of effective and gentle isolation and 111-In labelling of human platelets, as well as to employ these platelets in human clinical studies with the object of elucidating a number of physiological and pathophysiological mechanisms and processes in which platelets take part. 111-In-oxine presents obvious advantages over 51-Cr-sodium chromate; a high labelling efficiency, and more advantageous physical properties (a half life of 68 hours (against the half life of 28 days for 51-Cr) and considerably more effective gamma emission), making external registration by means of a gamma camera possible. Considering the role played by platelets in the development of atherosclerosis and its thromboembolic complications, in the early phases of deep venous thrombosis, and in graft rejection, it is natural that attempts have been made to use 111-In-labelled platelets for scintigraphic and kinetic evaluation of thromboembolic processes. Accumulation of 111-In-labelled platelets at sites of vessel wall injury, on pulmonary emboli (presumably on deep vein thrombi as well), and on catheter material has been demonstrated. Beyond this, the number of publications concerning the use of 111-In-labelled platelets for visualization of atherosclerosis, venous thromboembolism, arterial grafts, intracardiac thrombi, aortic aneurysms, renal allograft rejection, and other situations in which platelet thromboembolism takes place, provides evidence that a tool has finally been found for the study of their nature and response to therapeutic intervention. (eg)

  10. Vessel wall and indium-111-labelled platelet response to carotid endarterectomy

    International Nuclear Information System (INIS)

    Lusby, R.J.; Ferrell, L.D.; Englestad, B.L.; Price, D.C.; Lipton, M.J.; Stoney, R.J.

    1983-01-01

    Postendarterectomy platelet deposition and thrombus formation may play an important role not only in vessel wall healing but also in the small incidence of postoperative cerebral ischemia and postoperative stenosis. A study has been performed using a canine model to investigate the healing response to carotid endarterectomy and the validity of an in vivo indium-111 (In-111) radiotracer technique in the assessment of postendarterectomy deposition of autologous labelled platelets. Sixteen endarterectomized carotid arteries showed uptake of autologous In-111 platelets immediately after infusion, reaching a maximum by 1 hour with little increase at 24 or 48 hours. No uptake was seen in ten control vessels following platelet infusion (P less than 0.05). At autopsy, seven vessels were demonstrated to have In-111 platelet deposition immediately prior to sacrifice of the animals. Postmortem scanning confirmed the localization to the vessel lumens, and microscopy revealed thrombus formation with or without partial endothelialization. Complete reendothelialization had occurred in the vessels that failed to show platelet deposition. Delayed healing was associated with continuing platelet deposition, excessive thrombus formation, and luminal stenosis. Arteriotomy closure with a vein patch altered the healing characteristics of the vessel with segmental thrombus formation over the vein patch. A preliminary study of the postendarterectomy in vivo In-111 platelet response in humans demonstrated platelet deposition that was not influenced by the administration of antiplatelet drugs at currently prescribed levels

  11. Diagnosis of cardiac allograft rejection with indium-111 labeled platelets in cyclosporin treated rats

    International Nuclear Information System (INIS)

    Fawwaz, R.A.; Iga, C.; Hardy, M.A.; Alderson, P.O.

    1984-01-01

    Rejection of heart transplants remains difficult to diagnose. Indium-111 (In-111) labeled lymphocytes accumulate in rat cardiac allografts when recipients are treated with Cyclosporin (Cy), even in the absence of clinical rejection. This presumably occurs because of the non-specific 'interstitial infiltration' caused by Cy. This study examines the usefulness of In-111 labeled platelets in differentiating experimental cardiac allograft rejection from Cy-induced tissue changes. The authors initially examined the migration patterns of syngeneic In-111 labeled platelets in groups of Lewis recipients of ACI cardiac allografts treated with IM Cy (10mg/kg) for 6-14 days. In addition, 10 control animals were not immunosuppressed, and 10 were treated with Cy but received Lewis cardiac isografts. Syngeneic In-111 platelets were injected IV into each animal 24 hours prior to sacrifice. Three to five rats from each group were killed at 3 ,7, 14, 21 and 28 days after transplantation and the % ID/gm in the transplanted hearts and native hearts were determined and correlated with histopathology. Untreated Lewis recipients rejected ACI hearts in 6.5 +- 0.4 days while Cy prolonged allograft survival in a variable fashion. In-111 platelet accumulation correlated well with the degree of rejection determined independently by histopathology. No significant In-111 platelet accumulation was detected in non-rejecting cardiac transplants or in native hearts in Cy treated or control animals. The results suggest that In-111 labeled platelets will be an effective agent for diagnosis of cardiac rejection, even in the presence of Cy treatment

  12. Role of indium-111 labelled platelet scintigraphy in the management of thrombocytopenic patients with malignant neoplasms

    Energy Technology Data Exchange (ETDEWEB)

    Oriuchi, N.; Korkmaz, M.; Kim, E.E.; Delpassand, E.S.; Wong, F.; Podoloff, D.A. [Texas Univ., Houston, TX (United States). Dept. of Nuclear Medicine; Wallace, S. [Texas Univ., Houston, TX (United States). Dept. of Diagnostic Radiology

    1998-03-01

    This study was done to investigate the role of indium-111 labelled platelet scintigraphy in the treatment of thrombocytopenia in patients with malignant neoplasms. The study involved 20 consecutive patients with thrombocytopenia associated with malignant neoplasms or hematological disorders and without evidence of underproduction of megakaryocytes due to chemotherapy or bone marrow infiltration by the malignancy. Splenic sequestration of platelets was evaluated by measuring spenic uptake of {sup 111}In-labelled platelets, and findings were correlated with the outcome of splenectomy and medication. Of the 20 patients, 13 had splenic sequestration of platelets. Seven of the 13 patients underwent splenectomy; six of these seven patients experienced a complete response. The other six patients received medication only and showed no response. Of the seven patients without splenic sequestration of platelets, five received medication, and four of them responded to it. {sup 111}In-labelled platelet scintigraphy has a role in selecting appropriate therapy and predicting its efficacy in patients with thrombocytopenia associated with malignant neoplasms. (orig.)

  13. Role of indium-111 labelled platelet scintigraphy in the management of thrombocytopenic patients with malignant neoplasms

    International Nuclear Information System (INIS)

    Oriuchi, N.; Korkmaz, M.; Kim, E.E.; Delpassand, E.S.; Wong, F.; Podoloff, D.A.; Wallace, S.

    1998-01-01

    This study was done to investigate the role of indium-111 labelled platelet scintigraphy in the treatment of thrombocytopenia in patients with malignant neoplasms. The study involved 20 consecutive patients with thrombocytopenia associated with malignant neoplasms or hematological disorders and without evidence of underproduction of megakaryocytes due to chemotherapy or bone marrow infiltration by the malignancy. Splenic sequestration of platelets was evaluated by measuring spenic uptake of 111 In-labelled platelets, and findings were correlated with the outcome of splenectomy and medication. Of the 20 patients, 13 had splenic sequestration of platelets. Seven of the 13 patients underwent splenectomy; six of these seven patients experienced a complete response. The other six patients received medication only and showed no response. Of the seven patients without splenic sequestration of platelets, five received medication, and four of them responded to it. 111 In-labelled platelet scintigraphy has a role in selecting appropriate therapy and predicting its efficacy in patients with thrombocytopenia associated with malignant neoplasms. (orig.)

  14. Thrombokinetics with In-111-oxine labelled platelets

    International Nuclear Information System (INIS)

    Uchida, Tatsumi; Yui, Tokuo; Muroi, Shuichi; Matsuda, Shin; Kariyone, Shigeo

    1982-01-01

    Indium-111-oxine has been employed as a redioactive platelet label for thrombosis imaging and thrombokinetic studies in man. To evaluate it's suitability for platelet survival and turnover, thrombokinetic studies were carried out in hematological normal subjects, in patients with idiopathic thrombocytopenic purpura (ITP) and chronic congestive splenomegaly. For In-111-oxine labelled platelets, platelets were collected by differential centrifugation from 44 ml of whole blood drawn into 6 ml of acid citrate dextrose solution. Platelet suspension was incubated with In-111-oxine, which was extracted before use by the method of Thakur and co-workers. The survival, recovery and turnover of In-111-labeled platelets were 8.6 +- 0.5 days, 63.0 +- 5.4% and 3.9 +- 0.3 x 10 4 / μl/day, respectively, which were similar with those of Cr-51 method. Platelet disappearance curves labelled with In-111 and Cr-51 simultaneously were similar in one case. In patients with ITP, platelet survival shortened in the same degree with Cr-51 method. The two simultaneous labeling studies between In-111 and Cr-51 showed no differences. In the patients with congestive splenomegaly, the same results were obtained. Thrombokinetic studies with In-111-oxine labelled platelets offer the advantages of reduced blood requirements, and the ability to perform external imaging of platelet distribution. (author)

  15. The clinical utility of indium-111 labelled platelet scintigraphy in the diagnoses of renal transplant rejection

    International Nuclear Information System (INIS)

    Desir, G.V.; Bia, M.; Lange, R.C.; Smith, E.O.; Flye, W.; Kashgarian, M.; Schiff, M.; Ezekowitz, M.D.

    1990-01-01

    It is demonstrated that indium-111 labelled platelet scintigraphy is a highly accurate test for detecting acute untreated renal allograft rejection and it is shown that changes in platelet uptake can precede signs and symptoms of rejection by at least 48 hours. (author). 34 refs.; 2 figs.; 1 tab

  16. 111In,113In-labelled platelets. I

    International Nuclear Information System (INIS)

    Komarek, P.; Poledne, R.; Charvat, J.; Konopkova, M.; Komarkova, I.

    1983-01-01

    111 In-8-hydroxyquinoline (oxine) is used for labelling blood platelets which serves diagnostic purposes in medicine. For the preparation of the complex of radioactive indium with oxine, 111 In and sup(113m)In were used under optimal conditions. Two different preparation methods for the labelled complex are described. Both methods studied the effect of pH, the amount of chelate agents and the mode of filtration on the yields of the labelled oxine. The blood platelets labelling is influenced not only by the quality of labelled oxine but also by their number. The organ distribution in laboratory animals proved that platelets were not impaired during separation and labelling and that they were suitable for diagnostic use. (author)

  17. Clinical evaluation of the platelet scintigraphy using indium-111 oxine

    International Nuclear Information System (INIS)

    Ishikawa, Nobuyoshi; Takeda, Tohoru; Nakajima, Kohtaroh; Satoh, Motohiro; Akisada, Masayoshi; Ijima, Hiroshi

    1988-01-01

    The clinical usefulness of autologous platelets labeled with Indium-111 oxine was evaluated by scintigraphy as a diagnostic procedure for the detection of various thrombotic disorders as well as in different aneurysms. The positivity was found to be satisfactory (80.0 %) in cases of aortic aneurysm while thoracic aneurysm showed comparatively poor accumulation. High positivity was also demonstrated in deep vein thrombosis. The complimentary role of this method for intracardiac thrombi to echocardiography was noted. The labeling procedure of indium-111 oxine was fairly easy to perform and the activity of labeled platelets was sustained enough to yield good results. In one case scintigraphy was performed successfully after 19 hours of angiography when a hot area of labeled platelets was seen at the puncture site. This method was therefore varified to be a sensitive and reliable method in the assessment of thrombus activity, and as it demonstrates the activity, its helpfulness in the conservative treatment of these disorders is warranted. (author)

  18. Indium-111 oxine labelling of white blood cells

    International Nuclear Information System (INIS)

    Lavender, J.P.; Silvester, D.J.; Goldman, J.; Hammersmith Hospital, London

    1978-01-01

    Following work done by Professor John McAfee and Mathew Thakur at the MRS Cyclotron Unit a method is available for labelling cells with indium-111 which results in a stable intracellular marker. The method uses indium-111-8 hydroxyquinoline (111In oxine) which is a lipoid soluble complex which goes across the cell membrane and results in the deposition of indium into various subcellular structures. It has been applied to various preparations of white cells, platelets and also malignant cells. Autologous granulocytes have been used to identify inflammatory lesions in 35 patients. By similar means autologous lymphocytes can also be labelled and reinfused. Lymphocytes have been shown in animals to circulate from the blood via the lymphatic system and then returning to the blood once more. The same phenomenon can be seen in man using indium labelled lymphocytes. Lymph nodes become visible at between 12 and 18 hours and recirculation of labelled cells can be shown on the blood activity curves. Certain problems arise concerning cell behaviour after labelling which appear due to irradiation of cells rather than chemical toxicity. (author)

  19. Peripheral vascular investigations using indium 111 labeled platelets. Correlation between anatomical and scintigraphic data. A study of 131 cases

    International Nuclear Information System (INIS)

    Bernard, P.J.; Bazan, M.; Laforte, C. de.

    1985-01-01

    In comparison with other arterial investigations, indium 111 labeled scintigraphy appears to be a very suitable tool for the detection and observations of small foci of thrombosis and particularly for the determination of the evolutive character of the lesion. The conservation of the functional properties of labeled platelets is a determining factor in the results obtained [fr

  20. Site of destruction of 111 indium-labeled autologous platelets and effectiveness of splenectomy

    International Nuclear Information System (INIS)

    Najean, Y.; Dufour, Y.

    1991-01-01

    Platelet life-span was studied in 165 patients (including 25 children) with chronic idiopathic thrombocytopenic purpura (of at least one year duration) using 111 indium-oxinate-labeled autologous platelets. The site of platelet destruction was not correlated with age, severity of the disease or presence of immunologic anomalies; this site was characteristic of each individual and remained unchanged in a given patient when the test was repeated several times. Splenectomy was performed in 79 patients (at the discretion of physicians who elected splenectomy in 63% of patients with splenic destruction versus 26% only of patients with hepatic destruction). A very close correlation was found between site of destruction and efficiency of splenectomy. However, 13% of initially improved patients developed a recurrence. Spontaneous improvement was seen in only 8 of the non-splenectomized patients with long-term follow-ups (1-5 years) [fr

  1. Imaging experimental coronary artery thrombosis with indium-111 platelets

    International Nuclear Information System (INIS)

    Riba, A.L.; Thakur, M.L.; Gottschalk, A.; Zaret, B.L.

    1979-01-01

    The ability of cardiac scintigraphy with indium-111 ( 111 In)-labeled platelets to detect coronary artery thrombosis (CAT) was assessed in a canine model. Cardiac imaging and tissue distribution studies were performed shortly after administering 111 In-labeled platelets to 12 dogs (group 1) with acute CAT. Four dogs (group 2) with acute CAT were studied 2 and 22 hours after administering 111 In platelets. In addition, four dogs (group 3) with 24-hour-old CAT were similarly evaluated. In all group 1 animals, in vivo imaging 1 to 2 hours after 111 In platelet administration revealed intense uptake in the region of thrombus-containing left anterior descending arteries that was readily discernible from background blood pool activity. Sequential imaging of the four group 2 animals over a 22-hour period revealed no change in the scintigraphic pattern of the thrombosed arteries. In contrast, 111 In platelet imaging in the four group 3 animals with 24-hour-old CAT failed to reveal enhanced activity within the region of the thrombus-containing coronary artery. In the 12 group 1 animals, the CAT accumulated 69 +- 10 (mean +- SEM) times greater activity than present in blood and 651 +- 135 times greater activity than normal left ventricular myocardium. There was 24 +- 7 times greater 111 In activity in the damaged left anterior descending arteries compared with normal circumflex arteries. Similar uptake ratios were seen in group 2 animals. The 24-hour old thrombi from group 3 animals showed no enhanced 111 In uptake. This study demonstrates that experimental acute CAT can be detected readily with 111 In platelet cardiac scintigraphy

  2. Basic study of platelet labeling with 111In-oxine

    International Nuclear Information System (INIS)

    Yui, Tokuo; Uchida, Tatsumi; Matsuda, Shin; Muroi, Shuichi; Tanaka, Tetsugoro

    1981-01-01

    Indium-111-oxine has recently been suggested as a new isotopic labeling agent of platelets. In this paper, the results on the investigation of in vitro labeling of human platelets with In-111-oxine and those of platelet kinetics in rats are presented. Based on the findings of those studies, the protocol of human platelet labeling with In-111-oxine for clinical use was established. All operations should be carried out with sterile techniques at 20 - 25 0 C. 1) Forty four ml venous blood is drawn into a 50 ml polystyrene syringe containing 6 ml ACD-A. 2) The blood is transferred to a 50 ml tube and centrifuged at 300 g for 15 min. 3) Supernatant platelet rich plasma (PRP) is transferred to other 50 ml tube. Then, the pH is adjusted to 6.5 by addition of 1 ml ACD-A per 20 ml PRP. 4) Platelets are sedimented by centrifuging at 1,500 g for 15 min and resuspended in 3 ml ACD-A-saline solution (pH 6.5). 5) Three hundreds μCi of In-111-oxine is added to the platelet suspension. The mixture is incubated for 20 min at room temperature. 6) About 15 ml of the platelet poor autologous plasma (PPP) is added into the incubated mixture, followed by the sedimentation of labeled platelets (1,500 g, 15 min). 7) The labeled platelets are suspended in 10 ml PPP and the contaminating red cells are sedimented by centrifuging at 200 g for 5 min. 8) One hundred and fifty μCi of labeled platelet suspension is injected to the patient intravenously. The labeling efficiency in this method was 62 +- 5% (mean +- 1S.D., n = 6). (author)

  3. Biokinetics of indium-111 labeled platelets after cryotherapy of hepatic metastases

    International Nuclear Information System (INIS)

    Alexander, C.; Kirsch, C.-M.; Pistorius, G.; Feifel, G.

    2002-01-01

    Full text: The present investigation was performed to evaluate mean platelet live-span and the proportion of platelet disposal in different organs in patients after hepatic cryotherapy. Seven patients with advanced colorectal cancer and liver metastases were included. Directly before the surgical procedure a blood specimen was drawn and an in vitro labeling of patients platelets with 18 MBq Indium-111 oxime was performed. Reinjection was done intraoperatively just before cryotherapy. Blood specimen were drawn at 1, 2, 3, 24 und 48 h p.i.. Whole-body scintigraphy was acquired on day two alter operation. The evaluation comprised the calculation of mean platelet live-span and of organ activities as percentage of whole-body activity. The local disposal of platelets at the site of cryotherapy ranged from 0 to 35.2 percent, the mean value was 16,2 ± 12,2 percent (mean ± SD). The mean half-time of time-activity curve gave 0.6 to 2.4 days (mean ± SD: 1.6 ± 0.6 d; normal value: 3.5-6 d), the mean platelet life-span was between 2.1 and 5.2 days corresponding to a mean value of 3.4 ± 1.0 days (normal value: 7-11 d). The evaluation of SPECT slices of large liver metastases demonstrated that platelet disposal takes place at the border zone of the metastases just around the necrotic center. We conclude that the enhanced local platelet trapping is a major cause for cryothermia-induced systemic thrombocytopenia. (author)

  4. The use of indium-111 labeled platelet scanning for the detection of asymptomatic deep venous thrombosis in a high risk population

    International Nuclear Information System (INIS)

    Siegel, R.S.; Rae, J.L.; Ryan, N.L.; Edwards, C.; Fortune, W.P.; Lewis, R.J.; Reba, R.C.

    1989-01-01

    Five hundred indium-111 labeled platelet imaging studies (387 donor and 113 autologous) were performed postoperatively in 473 patients who had undergone total hip replacement, total knee replacement, or internal fixation of a hip fracture to detect occult deep venous thrombosis. All patients had been anticoagulated prophylactically with aspirin, warfarin sodium (Coumadin), or dextran. Thirty-four possible cases of proximal deep venous thrombosis were identified in 28 asymptomatic patients. To verify the scan results, 31 venograms were performed in 25 patients (three refused). In 21 of 31 cases, totally occlusive thrombi were detected; in 5 cases, partially occlusive thrombi were detected; in 5 cases, no thrombus was seen. No patient who had a negative scan nor any patient who had a verified positive scan (and received appropriate heparin therapy) subsequently developed symptoms or signs of pulmonary embolism. One hundred forty-one indium study patients also underwent Doppler ultrasonography/impedance plethysmography (Doppler/IPG) as a comparative non-invasive technique. In 137 cases, the results of the indium study and Doppler/IPG studies were congruent. The indium study had no false negative results that were detected by Doppler/IPG. No patient had any clinically evident toxicity. These results suggest that indium-111 labeled platelet scanning is a safe, noninvasive means for identifying DVT in high risk patients

  5. Quantification of the sequestration of indium 111 labelled platelets

    International Nuclear Information System (INIS)

    Najean, Y.; Picard, N.; Dufour, V.; Rain, J.D.

    1988-01-01

    A simple method is proposed for an accurate quantification of the splenic and/or hepatic sequestration of the 111 In-labelled platelets. It could be allow a better prediction of the efficiency of splenectomy in idiopathic thrombocytopenic purpura [fr

  6. A quantitative study of Indium-111-oxine platelet kinetics in acute and chronic renal transplant rejection

    International Nuclear Information System (INIS)

    Heyns, A. du P.; Pieters, H.; Badenhorst, P.N.; Wessels, P.; Loetter, M.G.; Minnaar, P.C.; Pauw, F.H.

    1982-01-01

    Thirteen patients were investigated on 22 occasions at times varying from 1 day to 10 years after living family donor or cadaver renal transplantation. Platelet survival in the circulation, and in vivo platelet distribution and sites of deposition and sequestration was quantitatively determined with Indium-111-oxine (In-111-oxine) labelled platelets and a scintillation camera interfaced with a computer assisted imaging system. In all patients platelet survival was shortened and the platelet survival curve exponential. In patients with no evidence of transplant rejection and those with chronic rejection, there was no measurable or visible accumulation of labelled platelets in the kidney. The sequestration pattern of In-111 labelled platelets at the end of platelet life span was within normal limits and located in the reticuloendothelial system. In those patients with acute transplant rejection, platelet survival was shortened. Labelled platelets accumulated in the kidney: this was clearly visualized on scintigraphy and reflected by a significant increase in the radioactivity count density of the kidney. Platelets not deposited in the transplant were sequestrated in the reticuloendothelial system. This study demonstrates the diagnostic value of In-111 labelled platelet kinetics in the investigation of acute renal failure after renal transplantation. This investigation appears of limited clinical value in chronic rejection. (orig.)

  7. Indium-111 labelled platelet scintigraphy can predict the immunological origin of fever in patients on dialysis carrying a non-functioning renal allograft

    International Nuclear Information System (INIS)

    Fuster, D.; Lomena, F.; Piera, C.; Setoain, F.J.; Laterza, C.; Herranz, R.; Setoain, J.; Torregrosa, J.V.; Oppenheimer, F.

    2000-01-01

    The purpose of this study was to evaluate the usefulness of labelled platelet scintigraphy in the differential diagnosis of a prolonged febrile syndrome (PFS) in patients on dialysis carrying a non-functioning renal allograft. We prospectively performed an indium-111 mercaptopyridine-labelled platelet scan on 91 patients (54 men, 37 women; mean age 39.6±12 years). The mean duration of PFS was 35 days (range 7-122). Forty-six of the 91 patients underwent steroid therapy (2- 10 mg/day). Platelet labelling was carried out following Thakur's method. Platelet scans were performed 48 h after reinjection of labelled platelets. The platelet uptake index (PUI) was calculated by dividing the cpm/pixel in the allograft ROI by cpm/pixel in a mirror background ROI. The final diagnosis of PFS was established depending on the outcome after treatment. In 61/91 patients the fever had an immunological origin because it disappeared after graft embolisation or transplantectomy. In 30/91 patients the PFS disappeared after antibiotic therapy (non-immunological origin). The PUI in patients with immunological PFS was 1.80±0.7, while in patients with non-immunological PFS it was 1.12±0.1 (P 111 In-labelled platelet scintigraphy can accurately predict an immunological PFS in patients on dialysis carrying a non-functioning renal allograft. Therapy with steroids could reduce the sensitivity of 111 In-labelled platelet scintigraphy in detecting immunological PFS. (orig.)

  8. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    Energy Technology Data Exchange (ETDEWEB)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V. (Mt. Sinai Medical Center, New York, NY (USA))

    1989-09-01

    Blood-pool subtraction has been proposed to enhance {sup 111}In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging.

  9. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V.

    1989-01-01

    Blood-pool subtraction has been proposed to enhance 111 In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging

  10. Quantitation of thrombogenicity of hemodialyzer with technetium-99m and indium-111 labeled platelets

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Kapadvanjwala, Mansoor; Ruzius, Kees; Serafini, A.N.; Zilleruelo, G.E.; Sfakianakis, G.N.

    1993-01-01

    The platelet thromobogenicity of a hemodialyzer was quantified with 99m Tc- and 111 In-labeled platelets. The platelets collected from blood of Beagle dogs, Yorkshire pigs and human volunteers were labeled with 111 in-tropolone (detergent-free) and 99m Tc-HMPAO. Hemodialysis was performed with a hollow-fiber dialyzer (HFD) in a flow-loop, the temperature of which was maintained at 37 o C, with flow-rates of 7, 150 and 270 mL/min; after dialysis, the HFD radioactivity was measured with an ionization chamber and imaged with a γ-camera. The radioactivity of samples of hollow-fibers taken from the top, middle and bottom of the dialyzer was determined with a γ-counter. The mean values of hemodialyzer-adherent platelet radioactivity were calculated for both radionuclides. The canine platelets were found to be more thrombogenic than porcine and human platelets. The adhesivity of porcine platelets to the biomaterial (cellulose-acetate) of the dialyzer approximated that of human platelets. The 99m Tc label underestimated the thrombus formation (P 111 In- and 99m Tc-labeled platelets suggests that both radionuclides could be used for measurement of device-induced thrombogenicity and may provide an estimation of prosthesis-induced thrombogenicity of human platelets from animal studies. (Author)

  11. Splenic dynamics of indium-111 labeled platelets in idiopathic thrombocytopenic purpura

    International Nuclear Information System (INIS)

    Syrjaelae, M.T.Sa.; Savolainen, S.; Nieminen, U.; Gripenberg, J.; Liewendahl, K.; Ikkala, E.

    1989-01-01

    Splenic dynamics of 111 In-labeled platelets and platelet-associated IgG in 33 patients with idiopathic thrombocytopenic purpura (ITP) were studied. Two half-lives were calculated for the biexponential splenic time-activity curve after i.v. injection of 111 In-labeled platelets. There was no difference in the mean half-life of the rapid component of the splenic curve (ST1) when patients with negative or slightly positive platelet suspension immunofluorescence test (PSIFT) were compared to those with strongly positive PSIFT (3.0 ± 0.7 min vs. 3.6 ± 0.4, p greater than 0.05). Mean half-life of the slow component of the splenic curve (ST2) was found to be longer in patients with a strongly positive than a negative or weakly positive PSIFT (26 ± 5 min vs. 13.2 ± 1.0 min, p less than 0.01). It seems that determination of the two components of the splenic time-activity curve provides a useful method for studying platelet kinetics in ITP

  12. Functional alterations of human platelets following indium-111 labelling using different incubation media and labelling agents

    International Nuclear Information System (INIS)

    Isaka, Yoshinari; Imaizumi, Masatoshi; Kimura, Kazufumi; Matsumoto, Masayasu; Kamada, Takenobu

    1991-01-01

    Human platelets were labelled in the absence of presence of plasma using 111 In-labelled oxine sulphate, tropolone or 2-mercaptopyridine-N-oxide (MPO). Under in vitro and in vivo conditions, platelet functions were evaluated by measuring their aggregability, survival, recovery and early distribution. High labelling efficiency was achieved in saline labelling, whereas with plasma labelling, it was necessary to concentrate the platelet-rich plasma to 4.8x10 6 platelets/μl. The aggregation of platelets labelled in plasma or saline was compared with that of controls; platelets labelled in saline showed lower aggregability in 2 μM ADP but not in 5 μM ADP nor with collagen. No significant differences in platelet survival and recovery were noted between platelets labelled in plasma and those labelled in saline. Our results indicate that partial loss of ADP aggregability in vitro does not influence the in vivo viability of platelets labelled in saline. Scintigraphic studies showed that platelets labelled in a saline medium were temporarily sequestrated in the liver but not in the spleen or heart. Thus, platelet labelling in saline does not affect platelet function adversely, but platelets labelled in plasma are more desirable for assessing the early distribution of platelets in the reticuloendothelial system. (orig.)

  13. Availability of 111In-labeled platelet scintigraphy in patients with postinfarction left ventricular aneurysm

    International Nuclear Information System (INIS)

    Tsuda, Takatoshi; Kubota, Masahiro; Iwakubo, Akifumi

    1989-01-01

    Eighteen patients with postinfarction left ventricular aneurysm (LVA) were examined with indium-111-labeled autologous platelet scintigraphy to identify intracardiac thrombi and to investigate the effect of antithrombotic agents on thrombogenesitiy within the LVA. Indium-111-platelet scintigraphy had a sensitivity of 60% and a specificity of 100% in detecting LVA mural thrombi. Among 6 patients showing false-negative scintigraphic studies, 4 was managed on antiplatelet therapy. Of 9 patients showing active platelet deposition on initial study, including 8 not receiving antiplatelet therapy, 5 were treated with tichlopidine (300 mg/day) for 29.8±5.0 days. For the 5 patients, 2 had resolution and the 3 others had interruption of intraaneurysmal deposition in the second platelet study. For one patient receiving the third platelet study after warfarin therapy, it took two weeks to completely interrupt platelet deposition within the LVA. ECG gated radionuclide ventriculography and thallium-201 myocardial SPECT were also performed to assess left ventricular wall motion of left ventricular ejection fraction (LVEF) and myocardial blood perfusion. Thallium-201 SPECT showed apical or anteroapical perfusion defects. Radionuclide ventriculography pinpointed all 18 apical and anteroseptal aneurysms. A comparison between the thrombus positive group and the thrombus negative group revealed no statistical differences in LVEF and the period from the last myocardial infarction to the initial platelet scanning. These results suggest that indium-111 labeled platelet scintigraphy may be useful for identifying active left ventricular mural thrombi and for judging antiplatelet and anticoagulant therapy. (Namekawa, K)

  14. Early image acquisition after administration of indium-111 platelets in clinically suspected deep venous thrombosis

    International Nuclear Information System (INIS)

    Farlow, D.C.; Ezekowitz, M.D.; Rao, S.R.; Martinez, C.; Denny, D.F.; Morse, S.S.; Decho, J.S.; Wackers, F.; Strauss, E.

    1989-01-01

    Indium-111 platelet scintigraphy accurately detects acute deep venous thrombosis in asymptomatic high-risk patients and may be used as a surveillance test. However, its value in symptomatic patients and its accuracy early after platelet injection are not satisfactorily established. The latter is important for timely institution of therapy. Accordingly, 65 patients (67 limbs) with suspected deep venous thrombosis (symptom duration 8 +/- 10 days, mean +/- standard deviation) were prospectively studied with platelet scintigraphy and contrast venography. Platelets were labeled with 405 +/- 101 mCi indium-111 oxine. The labeling efficiency was 80 +/- 10%. All images were acquired within 120 minutes after intravenous administration of the platelet suspension. Both platelet scintigraphy and venography were interpreted independently by 2 blinded observers (for each technique). Five separate analyses were performed. Each scintigraphic reader was compared to each venographic reader. A fifth analysis--consisting of readings with blinded agreement of both readings of the platelet scans and both readings of the venograms--was performed. Interobserver agreement was 92% for venography and 79% for scintigraphy. Excluding anticoagulated patients, the sensitivity of platelet scintigraphy was between 38 and 46% and the specificity was between 92 and 100%. Thus, early imaging of labeled platelets for the diagnosis of symptomatic deep venous thrombosis carries a high specificity but a much lower sensitivity. It is speculated that the low sensitivity is related to the inactivity of the thrombus. This may suggest that early imaging will only be useful in patients whose symptoms are of recent onset

  15. Quantitation of thrombogenicity of hemodialyzer with technetium-99m and indium-111 labeled platelets

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Kapadvanjwala, M.; Ruzius, K.; Serafini, A.N.; Zilleruelo, G.E.; Sfakianakis, G.N.

    1993-01-01

    The platelet thrombogenicity of a hemodialyzer was quantified with 99m Tc- and 111 In-labeled platelets. The platelets collected from blood of Beagle dogs, Yorkshire pigs and humans were labeled with 111 In-tropolone (detergent-free) and 99m Tc-HMPAO. Hemodialysis was performed with a hollow-fiber dialyzer (HFD) in a flow-loop, the temperature maintained at 37 o C, with flow-rates of 7, 150 and 270 mL/min; after dialysis, HFD radioactivity was measured with an ionization chamber and imaged with a γ-camera. The dynamic processes of thrombosis and embolization from the hemodialyzer resulted in large standard deviations around the mean values of the adherent thrombus. In spite of this, the quantitation of comparative thrombogenicity with 111 In-and 99m Tc-labeled platelets suggests that both radionuclides could be used for measurement of device-induced thrombogenicity and estimation of prosthesis-induced thrombogenicity. (author)

  16. The effect of ibuprofen on accumulation of indium-111-labeled platelets and leukocytes in experimental myocardial infarction

    International Nuclear Information System (INIS)

    Romson, J.L.; Hook, B.G.; Rigot, V.H.; Schark, M.A.; Swanson, D.P.; Lucchesi, B.R.

    1982-01-01

    To assess the ability of ibuprofen to influence the extent of platelet aggregation and leukocyte infiltration during acute myocardial infarction, autologous indium-111 ( 111 In)-labeled platelets or leukocytes were injected before 60 minutes of left circumflex coronary artery (LCx) occlusion, followed by 24 hours of reperfusion in the canine heart. Myocardial infarct size, as a percent of the area at risk, was reduced in the ibuprofen-treated group (12.5 mg/kg i.v. every 4 hours beginning 30 minutes before LCx occulsion) by 40%, from 48 +/- 4% in control animals to 29 +/- 4% in ibuprofen-treated dogs (p=0.005). Quantification of the platelet-associated 111 In radioactivity in irreversibly injured myocardium indicated that ibuprofen did not alter the accumulation of platelets in infarcted myocardium. In contrast, leukocyte accumulation in infarcted tissue was reduced significantly. In tissue samples with 0.41-0.60 gram infarct, the infarcted/normal ratio of leukocyte radioactivity was 12 +/- 2 in control dogs and 4 +/- 1 in ibuprofen-treated dogs, which represents a 67% reduction in leukocyte accumulation in ibuprofen-treated compared with control dogs. Similar reductions were found in other gram-infarct-weight categories. Although both platelets and leukocytes acumulate in infarcted canine myocardium, ibuprofen may exert its beneficial effect on ischemic myocardium by suppressing the inflammatory response associated with myocardial ischemia and infarction

  17. Quantitation of thrombogenicity of hemodialyzer with technetium-99m and indium-111 labeled platelets

    Energy Technology Data Exchange (ETDEWEB)

    Dewanjee, M.K.; Kapadvanjwala, Mansoor; Ruzius, Kees; Serafini, A.N.; Zilleruelo, G.E.; Sfakianakis, G.N. (Miami Univ., FL (United States). School of Medicine Althin CD-Medical Inc., Miami Lakes, FL (United States))

    1993-07-01

    The platelet thromobogenicity of a hemodialyzer was quantified with [sup 99m]Tc- and [sup 111]In-labeled platelets. The platelets collected from blood of Beagle dogs, Yorkshire pigs and human volunteers were labeled with [sup 111]in-tropolone (detergent-free) and [sup 99m]Tc-HMPAO. Hemodialysis was performed with a hollow-fiber dialyzer (HFD) in a flow-loop, the temperature of which was maintained at 37[sup o]C, with flow-rates of 7, 150 and 270 mL/min; after dialysis, the HFD radioactivity was measured with an ionization chamber and imaged with a [gamma]-camera. The radioactivity of samples of hollow-fibers taken from the top, middle and bottom of the dialyzer was determined with a [gamma]-counter. The mean values of hemodialyzer-adherent platelet radioactivity were calculated for both radionuclides. The canine platelets were found to be more thrombogenic than porcine and human platelets. The adhesivity of porcine platelets to the biomaterial (cellulose-acetate) of the dialyzer approximated that of human platelets. The [sup 99m]Tc label underestimated the thrombus formation (P < 0.01 ). The dynamic processes of thrombosis and embolization from the hemodialyzer resulted in the large standard deviations around the mean values of the adherent thrombus. In spite of this limitation of the dynamic pathology, the quantitation of comparative throbogenicity with [sup 111]In- and [sup 99m]Tc-labeled platelets suggests that both radionuclides could be used for measurement of device-induced thrombogenicity and may provide an estimation of prosthesis-induced thrombogenicity of human platelets from animal studies. (Author).

  18. In vivo quantitation of platelet deposition on human peripheral arterial bypass grafts using indium-111-labeled platelets. Effect of dipyridamole and aspirin

    International Nuclear Information System (INIS)

    Pumphrey, C.W.; Chesebro, J.H.; Dewanjee, M.K.; Wahner, H.W.; Hollier, L.H.; Pairolero, P.C.; Fuster, V.

    1983-01-01

    Indium-111-labeled autologous platelets, injected 48 hours after operation, were used to evaluate the thrombogenicity of prosthetic material and the effect of platelet inhibitor therapy in vivo. Dacron double-velour (Microvel) aortofemoral artery bifurcation grafts were placed in 16 patients and unilateral polytetrafluoroethylene femoropopliteal grafts were placed in 10 patients. Half the patients in each group received platelet inhibitors before operation (dipyridamole, 100 mg 4 times a day) and after operation (dipyridamole, 75 mg, and acetylsalicylic acid, 325 mg 3 times a day); the rest of the patients served as control subjects. Five-minute scintigrams of the graft region were taken with a gamma camera interfaced with a computer 48, 72, and 96 hours after injection of the labeled platelets. Platelet deposition was estimated from the radioactivities of the grafts and expressed as counts per 100 pixels per microcurie injected. Dipyridamole and aspirin therapy significantly reduced the number of platelets deposited on Dacron grafts and prevented platelet accumulation over 3 days. With the small amount of platelet deposition on polytetrafluoroethylene femoropopliteal artery grafts even in control patients, platelet inhibitor therapy had no demonstrable effect on platelet deposition on these grafts. It is concluded that (1) platelet deposition on vascular grafts in vivo can be quantitated by noninvasive methods, and (2) dipyridamole and aspirin therapy reduced platelet deposition on Dacron aortofemoral artery grafts

  19. Availability of /sup 111/In-labeled platelet scintigraphy in patients with postinfarction left ventricular aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, Takatoshi; Kubota, Masahiro; Iwakubo, Akifumi and others

    1989-03-01

    Eighteen patients with postinfarction left ventricular aneurysm (LVA) were examined with indium-111-labeled autologous platelet scintigraphy to identify intracardiac thrombi and to investigate the effect of antithrombotic agents on thrombogenesitiy within the LVA. Indium-111-platelet scintigraphy had a sensitivity of 60% and a specificity of 100% in detecting LVA mural thrombi. Among 6 patients showing false-negative scintigraphic studies, 4 was managed on antiplatelet therapy. Of 9 patients showing active platelet deposition on initial study, including 8 not receiving antiplatelet therapy, 5 were treated with tichlopidine (300 mg/day) for 29.8+-5.0 days. For the 5 patients, 2 had resolution and the 3 others had interruption of intraaneurysmal deposition in the second platelet study. For one patient receiving the third platelet study after warfarin therapy, it took two weeks to completely interrupt platelet deposition within the LVA. ECG gated radionuclide ventriculography and thallium-201 myocardial SPECT were also performed to assess left ventricular wall motion of left ventricular ejection fraction (LVEF) and myocardial blood perfusion. Thallium-201 SPECT showed apical or anteroapical perfusion defects. Radionuclide ventriculography pinpointed all 18 apical and anteroseptal aneurysms. A comparison between the thrombus positive group and the thrombus negative group revealed no statistical differences in LVEF and the period from the last myocardial infarction to the initial platelet scanning. These results suggest that indium-111 labeled platelet scintigraphy may be useful for identifying active left ventricular mural thrombi and for judging antiplatelet and anticoagulant therapy. (Namekawa, K).

  20. Mathematical models for the study of the dynamics of indium-111-labelled platelets in idiopathic thrombocytopenic purpura

    International Nuclear Information System (INIS)

    Savolainen, S.

    1992-01-01

    Platelet kinetics in patients with idiopathic thrombocytopenic purpura (ITP) was investigated by applying various models (compartmental and open models, and functional and uptake analyses) to data on indium-111 labelled platelets monitored with a gamma camera following intravenous injection of labelled platelets. The usefulness of the selected models was tested by relating kinetic data to pathophysiological phenomena. A comparison of the results of platelet and colloid kinetics showed that the splenic platelet kinetics in ITP patients does not seem to be primarily dependent on the reticuloendothelial system. Although closed three-compartmental analysis seemed to be superior to the other models applied, none of the methods of analysis tested in this study appears to provide a complete description of short-lived platelet dynamics, as for every model certain assumptions that are not entirely relevant have to be made; this stresses the importance of combining various methods for a comprehensive analysis of a complex phenomenon. Conclusions concerning the function of biological systems should be based on more than one dynamic model or calculation method, since applying only one model (or calculation method) may give artifactual results due to poor statistics of observed data or to inexactness of the assumptions concerning the model

  1. Visualization of a prosthetic vascular graft due to platelet contamination during 111Indium-labeled leukocyte scintigraphy

    International Nuclear Information System (INIS)

    Oates, E.; Ramberg, K.

    1988-01-01

    A prosthetic axillo-femoral bypass graft was visualized during 111 In-labeled leukocyte scintigraphy in a patient referred for possible abdominal abscess. The presence of significant cardiac blood-pool activity raised the possibility that this uptake was due to deposition of contaminating labeled platelets rather than labeled leukocytes. An analysis of a small sample of the patient's blood confirmed that the circulating activity was due to labeled platelets. Increased activity along prosthetic vascular grafts in patients undergoing 111 In-labeled leukocyte scintigraphy may be due to adherent platelet, and not indicative of infection

  2. Life span and tissue distribution of 111indium-labeled blood platelets in hypomagnesemic lambs

    International Nuclear Information System (INIS)

    Schneider, M.D.; Miller, J.K.; White, P.K.; Ramsey, N.

    1983-01-01

    Circulating platelets may be activated by exposed triple-helical collagen in atherosclerotic lesions in Mg-deficient ruminants. Autologous platelets, labeled in vitro with 111In and determined to be active, were injected into 5 hypomagnesemic and 3 control lambs fed semipurified diets with 100 or 2,000 mg of Mg/kg of feed for 3 months. During the first 68 hours, 111In concentrations were 11 times higher in packed cells than in plasma. Packed-cell 111In increased 60% during the first 2 hours, probably due to initial tissue sequestration and later release of labeled platelets. Thereafter, platelet half-life span averaged 60 and 63 hours for hypomagnesemic and control lambs. After 68 hours, lambs were injected with native vascular collagen fibrils at 500 micrograms/kg of body weight to initiate reversible platelet aggregation. Within 1 minute, 83% of packed-cell 111In disappeared from circulation. Thirty minutes later, the lambs were euthanatized and necropsied and in the lungs, liver, and spleen, 111In averaged 24%, 19%, and 9%, respectively, of 111In injected 68 hours earlier. Organ deposits were not affected by Mg intake, but 111In in the lungs was somewhat lower in 2 lambs injected with inactivated collagen. Pathologic changes induced by reversible platelet aggregation were compatible with right ventricular failure complicated by pulmonary edema, similar to changes in hypomagnesemic lambs that died spontaneously. Platelets in blood exposed to vascular lesions in hypomagnesemic ruminants could be a major mortality risk factor in grass tetany disease

  3. Imaging experimental infective endocarditis with indium-111-labeled blood cellular components

    International Nuclear Information System (INIS)

    Riba, A.L.; Thakur, M.L.; Gottschalk, A.; Andriole, V.T.; Zaret, B.L.

    1979-01-01

    The capability of radionuclide imaging to detect experimental aortic valve infective endocarditis was assessed with indium-111 ( 111 In)-labeled blood cells. Sequential cardiac imaging and tissue distribution studies were obtained in 17 rabbits with infective endocarditis after administration of 111 In-platelets and in five after 111 In-polymorphonuclear leukocytes. Forty-eight to 72 hours after platelet administration, in vivo imaging demonstrated abnormal 111 In uptake in all animals in the region of the aortic valve in an anatomically distinct pattern. Images of the excised heart showed discrete cardiac uptake conforming to the in vivo image and gross pathological examination. 111 In-platelet uptake in vegetations from the 17 animals averaged 240 +- 41 times greater than that in normal myocardium and 99 +- 15 times greater uptake in blood. In contrast, 111 In-leukocyte cardiac imaging showed no abnormal aortic valve uptake 24 hours after tracer administration and the lesion myocardium activity ratio was only 5 +- 2 (3 +- 1 for lesion/blood activity). Four normal rabbits demonstrated neither positive 111 In-platelet scintigraphs nor abnormal cardiac tissue uptake. Likewise, noncellular 111 In was not concentrated to any significant extent in three animals with infective endocarditis. This study demonstrates that 111 In-platelet, but not leukocyte cardiac imaging, is a sensitive technique for detecting experimental infective endocarditis. The imaging data conform to the cellular pathology of the infective endocarditis vegetation

  4. Comparison of 111In-oxine and 111In-acetylacetone for the labeling of cells: in vivo and in vitro biological testing

    International Nuclear Information System (INIS)

    Mathias, C.J.; Heaton, W.A.; Welch, M.J.

    1981-01-01

    Several complexes of indium were compared as cell labels: indium-111-acetylacetone, indium-111-oxine, and indium-111-chloride complexed with 8-hydroxyquinoline (oxine) immediately prior to use. In labeling with acetylacetone, it was shown that the labeling efficiency is directly proportional to the amount of acetylacetone present, but the cell viability (as measured by in vitro aggregation studies), is inversely proportional to the amount of acetylacetone present. Biological studies were carried out in dogs using indium-111-labeled platelets; survival times and recovery values obtained with platelets labeled using all three techniques were similar. The same solutions were also used to label white blood cells; labeling efficiencies of greater than 80% were obtained in all cases, and the viability (as measured by trypan blue exclusion) was high in all cases. Chemotactic ability of the white cells labeled with indium-111-oxine is higher than that of unlabeled control cells; however, cells labeled with indium-111-acetylacetone were the same as the unlabeled control cells. (author)

  5. Scintigraphic detection of thrombi using indium-111-labeled autologous platelets

    International Nuclear Information System (INIS)

    Ikeoka, Kiyomitsu; Todo, Yasuhiro; Konishiike, Atsushi; Fujisue, Ryu; Ohyanagi, Mitsumasa; Yasutomi, Nagao; Tanimoto, Masaho; Kawai, Yoshitaka; Iwasaki, Tadaaki

    1985-01-01

    Intracardiac and arterial thrombi were examined by scintigraphy using In-111-oxine labeled autologous platelets. 1. In 22 cases of myocardial infarction including six with ventricular aneurysms, four had positive findings of thrombi on imaging and detected also by echocardiography. All four had ventricular aneurysms. The so-called ''moya-moya'' echoes (fuzzy echoes) were demonstrated in two of these four cases. 2. We encountered two cases with positive findings on imaging in 13 with mitral valve disease. These two had systemic embolic episodes after scintigraphic examination. ''Moya-moya'' echoes were detected in the left atrial cavity in four with negative findings on imaging. 3. Positive images were obtained in two of three with acute arterial occlusive disease, and in both cases platelet deposition was observed in the proximal site of obstruction. Though thrombectomy was performed for one of these two cases, no thrombus was detected at the site of platelet deposition. After one month, re-examination revealed only negative findings in all sites in both these patients. 4. In the six cases of aortic aneurysm, three had platelet deposition within their aneurysms, and surgery was performed for these positive cases, but one of them had no thrombus. 5. Positive images were obtained in only one of seven patients with chronic arterial occlusive disease. 6. Coagulation tests and platelet studies were investigated for patients with positive or negative platelet scans. Only the data of the thrombo-test showed a significant difference (97 +- 9 % vs 23 +- 7 %, p < 0.001). Three cases of positive imaging became negative after anticoagulant therapy. 7. We tried ECT for eight cases 24 hours after injection of In-111-oxine labeled platelets. Three cases showed clear images of thrombi, while the planar images could not detect them at an early stage. Therefore, we propose that ECT can be a useful technique for diagnosing intracardiac thrombi in early stage. (author)

  6. Increased deoposition of 111indium labelled platelets in chronically rejected kidney transplants

    International Nuclear Information System (INIS)

    Leithner, C.; Syre, G.

    1982-01-01

    Increased deposition of 111 In-oxine labelled autologous platelets in chronically rejected kidney transplants was demonstrated using a gamma-camera and by measurement of a platelet uptake index (PUI). In this group of patients the PUI correlated indirectly with the platelet half-life and was statistically different from the PUI found in stable transplant patients who acted as controls. It is therefore suggested that platelets may play a key role in chronic rejection by the release of a mitogenic factor which promotes the development of obliterative arterial lesions in the transplant. (orig.)

  7. Indium-111-oxine labeled platelet scintigraphy for detection of intracardiac and intravascular thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Michio; Ojima, Kenji; Tsuda, Takashi [Niigata Univ. (Japan). School of Medicine

    1983-09-01

    This study was designed to evaluate the efficacy of scintigraphy by using /sup 111/In-oxine labeled platelets for the detection of either intracardiac or intravascular thrombi. Fourteen cases of thrombi diagnosed or suspected on the basis of either angiography or two-dimensional echography were examined. They included four cases of left ventricular thrombi, three of left atrial thrombi, four of vascular thrombi and three of inflammatory disease. Platelet samples from the patients were labeled by /sup 111/In-oxine according to the method originated by Yui et al. The labeling efficiency was 72.4+-9.8%. The platelets retained good function except for collagen aggregability. Hot areas of high quality in the scintigram were demonstrated in six cases including two with left ventricular thrombi, two with left atrial thrombi and two with vascular thrombi. These areas accorded well with the findings of angiography, echography or surgery. The removed thrombi had a layer of aggregated platelets on the surface. Platelet survival was shortened in a case of prosthetic valve endocarditis without a hot area, and was normal in four out of the five cases including two with a hot area. It is concluded that this method is potentially predictive in detecting thrombi.

  8. Indium-111 platelet scintigraphy in carotid disease

    International Nuclear Information System (INIS)

    Branchereau, A.; Bernard, P.J.; Ciosi, G.; Bazan, M.; de Laforte, C.; Elias, A.; Bouvier, J.L.

    1988-01-01

    Forty-five patients (35 men, 10 women) undergoing carotid surgery had Indium-111 platelet scintigraphy as part of their preoperative work-up. Imaging was performed within three hours after injection of the Indium-111. A second series of views was obtained 24 hours later and repeated at 24 hour intervals for two days. Of 54 scintigrams, 22 were positive and 32 negative. Positive results were defined as a twofold or more increase in local activity on a visualized carotid after 24 hours. The sensitivity of the method was 41%, intraoperatively, and the specificity, 100%. The low sensitivity places this method behind sonography and duplex-scanning for screening patients for surgery. We believe that indications for platelet scintigraphy are limited to: 1. Repeated transient ischemic attacks in the same territory with minimal lesions on arteriography and non-homogeneous plaque on duplex scan; 2. Symptomatic patients being treated medically as a possible argument for surgery; 3. Determining therapeutic policy for patients having experienced a transient ischemic attack with a coexisting intracardiac thrombus

  9. Effect of aspirin and ticlopidine on platelet deposition in carotid atherosclerosis: assessment by indium-111 platelet scintigraphy

    International Nuclear Information System (INIS)

    Isaka, Y.; Kimura, K.; Etani, H.; Uehara, A.; Uyama, O.; Yoneda, S.; Kamada, T.; Kusunoki, M.

    1986-01-01

    The antiplatelet effects of aspirin and ticlopidine were studied by a dual-tracer method, using indium-111 labeled platelets and technetium-99m human serum albumin, in a group of 12 patients with suspected ischemic cerebrovascular disease. The magnitude of platelet accumulation at the carotid bifurcation was expressed as the ratio of radioactivity of indium-111 platelets deposited on the vascular wall to those circulating in the blood-pool (PAI, platelet accumulation index), 48 hr after injection of labeled platelets. PAI values were measured before (baseline studies) and after the antithrombotic therapies (aspirin studies: 325 mg bid for 22.3 +/- 1.3 days, ticlopidine studies: 100 mg tid for 21.8 +/- 2.1 days). At the baseline, the mean PAI value at 24 carotid bifurcations in the patient group was 15.7 +/- 15.3% (mean +/- S.D.) compared to -4.3 +/- 9.1 at 24 carotid bifurcations in 12 normal subjects (p less than 0.01). We defined the upper limit for a normal PAI (%) value to be +13.9, namely the mean PAI plus 2 SD for the carotid bifurcation in normal subjects and used this value for semiquantitative analysis. At the baseline, significant elevation of PAI (more than 13.9%; positive scintigram) was observed at 12 of 24 vessels, while 12 other regions were negative (less than 13.9%). In the lesions with positive scintigraphic results at the baseline, the mean PAI (%) value from the baseline, aspirin and ticlopidine studies was 29.5 +/- 7.0, 11.2 +/- 8.5 (p less than 0.01 versus baseline) and 21.4 +/- 21.3 (not significant from baseline), respectively

  10. Labelling of human platelets with 111indium-oxine and 99m-Tc-oxine. Comparison of in vitro and clinical use for monitoring of kidney transplants

    International Nuclear Information System (INIS)

    Angelberger, P.; Sinzinger, H.; Kolbe, H.; Leithner, Ch.

    1981-01-01

    One of the earliest signs of acute kidney transplant rejection are thrombotic depositions in the glomerulae vessels of the transplant. After injection of radioactive labelled platelets, the cell deposition can be visualized using a gamma camera. The authors have investigated cell labelling with 111 indium-oxine and with 99m-Tc-oxine (half life 6 hours) and have studied the usefulness of these methods for the detection of transplant rejection. (Auth.)

  11. Platelet kinetics with indium-111 platelets: comparison with chromium-51 platelets

    International Nuclear Information System (INIS)

    Peters, A.M.; Lavender, J.P.

    1983-01-01

    The application of 111In-oxine to platelet labeling has contributed to the understanding of platelet kinetics along three lines: 1. It allows the measurement of new parameters of splenic function, such as the intrasplenic platelet transit time, which has shed new light on the physiology of splenic blood cell handling. 2. It facilitates the measurement of platelet life span in conditions, such as ITP, in which 51Cr may undergo undesirable elution from the platelet as a result of platelet-antibody interaction. 3. It allows the determination of the fate of platelets, that is, the site of platelet destruction in conditions in which reduced platelet life span is associated with abnormal platelet consumption, as a result of either premature destruction of ''abnormal'' platelets by the RE system, or the consumption (or destruction) of normal platelets after their interaction with an abnormal vasculature. Future research using 111In platelets may yield further valuable information on the control as well as the significance of intrasplenic platelet pooling, on the role of platelets in the development of chronic vascular lesions, and on the sites of platelet destruction in ITP. With regard to the latter, methods will have to be developed for harvesting sufficient platelets representative of the total circulating platelet population from severely thrombocytopenic patients for autologous platelet labeling. This would avoid the use of homologous platelets, which is likely to be responsible for some of the contradictory data relating to the use of radiolabeled platelet studies for the prediction of the response of patients with ITP to splenectomy

  12. Pharmacokinetics of indium-111-labeled antimyosin monoclonal antibody in murine experimental viral myocarditis

    International Nuclear Information System (INIS)

    Yamada, T.; Matsumori, A.; Watanabe, Y.; Tamaki, N.; Yonekura, Y.; Endo, K.; Konishi, J.; Kawai, C.

    1990-01-01

    The pharmacokinetics of indium-111-labeled antimyosin monoclonal antibody Fab were investigated with use of murine experimental viral myocarditis as a model. The biodistribution of indium-111-labeled antimyosin antibody Fab on days 3, 5, 7, 14, 21 and 28 after encephalomyocarditis virus inoculation demonstrated that myocardial uptake increased significantly on days 5, 7 and 14 (maximum on day 7) in infected versus uninfected mice (p less than 0.001). In vivo kinetics in infected mice on day 7 demonstrated that the heart to blood ratio reached a maximum 48 h after the intravenous administration of indium-111-labeled antimyosin Fab, which was considered to be the optimal time for scintigraphy. The scintigraphic images obtained with indium-111-labeled antimyosin Fab demonstrated positive uptake in the cardiac lesion in infected mice. The pathologic study demonstrated that myocardial uptake correlated well with pathologic grades of myocardial necrosis. High performance liquid chromatography revealed the presence of an antigen-antibody complex in the circulation of infected mice after the injection of indium-111-labeled antimyosin Fab. This antigen bound to indium-111-labeled antimyosin Fab in the circulation might be whole myosin and this complex may decrease myocardial uptake and increase liver uptake. It is concluded that indium-111-labeled antimyosin monoclonal antibody Fab accumulates selectively in damaged heart tissue in mice with acute myocarditis and that indium-111-labeled antimyosin Fab scintigraphy may be a useful method for the visualization of acute myocarditis

  13. Imaging the inflammatory response to acute myocardial infarction in man using indium-111-labeled autologous platelets

    International Nuclear Information System (INIS)

    Davies, R.A.; Thakur, M.L.; Berger, H.J.; Wackers, F.J.T.; Gottschalk, A.; Zaret, B.L.

    1981-01-01

    The feasibility of imaging the inflammatory response to acute transmural myocardial infarction in man using indium-111 ( 111 In)-labeled autologous leukocytes was assessed in 36 patients. Indium-111 leukocytes were injected i.v. 18 to 112 hs after the onset of chest pain. Cardiac imaging was performed 24 hs later with a mobile gamma camera. Twenty-one patients had positive images and 15 had negative images. The percent of positive images increased as the interval between infarction and 111 In-leukocyte injection shortened; all patients injected within 24 hs of infarction had positive images. Patients with positive images were injected with 111 In leukocytes earlier after infarction and were younger than those with negative images. Several other parameters that could possibly have affected the imaging results were examined and were not significantly different in patients with positive and negative images. These included peak serum creatine kinase, location of infarction, incidence of pericarditis, use of antiinflammatory drugs or membrane-active antiarrhythmic drugs, peripheral leukocyte count, and cell labeling efficiency. The function of the labeled cells was similar in patients with positive and negative images. Six patients with acute infarction serving as controls and given free 111 In-oxine and six patients with stable coronary artery disease given 111 In-leukocytes all had negative cardiac images

  14. Utility of indium-111 labelled autologous platelets in the diagnosis of renal graft rejection

    International Nuclear Information System (INIS)

    Martin-Comin, J.; Roca, M.; Grino, J.M.; Paradell, C.; Caralps, A.

    1982-01-01

    The usefulness of In-111 labelled autologous platelets in the diagnosis of renal graft rejection was studied. The method is based on imaging of the graft area at 4, 24, 48 and 72 hours after the injection of the labelled cells. The study was done in 21 renal cadaveric transplant recipients: control group: four patients without evidence of rejection. No platelet uptake was observed in any of them. Study group: in 13 patients with acute rejection and 1 with chronic rejection graft tracer uptake was seen. In the 3 others with a non-immunological sudden impairment of renal function, no activity was detected in graft area. Changes in renal platelet trapping correlated with response to antirejection therapy

  15. Kinetics of short-lived Indium-111 radiolabelled platelets

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M.; Saverymuttu, S.H.; Bell, R.N.; Lavender, J.P. (Hammersmith Hospital, London, U.K.)

    1985-01-01

    We have studied the kinetics of autologous /sup 111/In-labelled platelets in patients with reduced platelet life span (<4.5 d), most of whom were thrombocytopenic, and of homologous /sup 111/In-labelled platelets in patients with severe thrombocytopenia. Intrasplenic platelet transit time (t) was calculated by compartmental and deconvolution analysis. In patients with a mean platelet life span of less than a few h, compartmental analysis may not be valid and so only deconvolution analysis was applied. There was a close correlation between values of t given by the two approaches (r=0.88, n=18, P<0.001). In some patients with severely reduced mean platelet life span (MPLS), the deconvolved splenic platelet clearance curves appeared to approach an asymptote, the relative magnitude of which was indicative of the irreversible extraction fraction by the spleen of incoming platelets. In other patients with severely reduced MPLS resulting from abnormal intra-hepatic platelet destruction, the deconvolved splenic curves resembled the normal. The intrasplenic platelet transit time showed no clear relationship with other parameters. It was concluded that platelet pooling within the spleen is normal in patients with reduced platelet life span,including idiopathic thrombocytopenic purpura, even when the predominant site of destruction is the spleen, and that platelets are not delayed in transit through the spleen in preparation of their removal from the circulation and ultimate destruction.

  16. Comparison of indium 111 oxine-labeled platelet aggregation between sutured and argon laser-assisted vascular anastomoses

    International Nuclear Information System (INIS)

    Fujitani, R.M.; White, R.A.; Kopchok, G.E.; Vlasak, J.; Marcus, C.S.; White, G.H.

    1988-01-01

    The thrombogenicity of argon laser-assisted vascular anastomoses (LAVAs) was compared with that of sutured vascular anastomoses (SVAs) by measurement of platelet aggregation at the site of repair in a canine model. Sequential 1 cm longitudinal carotid and femoral arteriotomies (n = 80) or jugular and femoral phlebotomies (n = 80) were performed, with each vessel having two tandem, randomly positioned arteriotomies or phlebotomies separated by a 4 cm length of intact vessel. One incision was repaired by SVA with continuous 6-0 polypropylene sutures and the other by argon LAVA. For the laser fusions, argon laser energy was applied to the adventitial surface of the vessel with a 300 micron fiberoptic probe with 0.5 W power, 1100 joules per square centimeter energy fluence, and 150 second exposure per 1 cm length. The arterial and venous segments of SVAs and LAVAs and an equivalent length of normal vessel were harvested at 48 hours (n = 16, 16, 16), 2 weeks (n = 12, 12, 12), and 4 weeks (n = 12, 12, 12). Autologous indium 111 oxine-labeled platelets were injected intravenously 48 hours before removal of the vascular repairs and the radioactivity of the specimens was determined on removal with a NaI (T1) well-type scintillation counter. Anastomotic platelet adherence index (APAI) was calculated as the ratio of emissions of SVA or LAVA to normal reference vessel

  17. Current status of indium-111 labeled bleomycin for tumor detection

    International Nuclear Information System (INIS)

    Taylor, R.D.; Blahd, W.H.

    1975-01-01

    The advantages and disadvantages of 111 In-labeled bleomycin for tumor detection are briefly mentioned. Indium-111 labeled bleomycin does localize in human tumors. However, its role in tumor detection and staging as compared with 67 Ga is still somewhat controversial

  18. Radioactive indium labelling of the figured elements of blood. Method, results, applications

    International Nuclear Information System (INIS)

    Ducassou, D.; Nouel, J.P.

    Following the work of Thakur et al. the authors became interested in red corpuscle, leucocyte and platelet labelling with indium 111 or 113m (8 hydroxyquinolein-indium). For easier labelling of the figured elements of blood the technique described was modified. The chelate is prepared by simple contact at room temperature of indium 111 or 113m chloride and water-soluble 8 hydroxyquinolein sulphate, in the presence of 0.2M TRIS buffer. The figured element chosen suspended in physiological serum is added directly to the solution obtained, the platelets and leucocytes being separated out beforehand by differential centrifugation. While it gives results similar to those of Thabur et al. the method proposed avoids the chloroform extraction of the radioactive chelate and the use of alcohol, liable to impair the platelet regation capacity [fr

  19. Indium-111 labeled purified granulocytes in the diagnosis of synthetic vascular graft infection

    International Nuclear Information System (INIS)

    Forstrom, L.A.; Dewanjee, M.K.; Chowdhury, S.; Brown, M.L.

    1988-01-01

    Indium-111 labeled leukocytes have been shown to be useful in the diagnosis of synthetic vascular graft infection. To minimize the potential effects of labeled red blood cells and platelets on image interpretation, the authors prepared purified autologous granulocytes (PG) from 84 ml of blood using Volex enhanced gravity sedimentation and Ficoll-Hypaque double density centrifugation. The labeling efficiency of PG with In-111 tropolone was 90 +/- 9% (mean +/- SD). Imaging was performed 18-24 hours following injection of approximately 445 microcuries of In-111 PG in 26 patients with suspected infection of vascular grafts that had been implanted 12 days to 12 years prior to the study. In ten patients with proven graft infection, seven had positive In-111 PG scans. Ten of 11 patients without infection had negative scans. In five patients with clinically equivocal findings, scan results were positive in one, negative in one, and equivocal in three. A false-positive scan occurred in a patient with an uninfected inflammatory pseudoaneurysm of an aortic graft. These results confirm an earlier report that In-111 PG imaging is a useful technique in the diagnosis of synthetic vascular graft infection

  20. The kinetics of short-lived Indium-111 radiolabelled platelets

    International Nuclear Information System (INIS)

    Peters, A.M.; Saverymuttu, S.H.; Bell, R.N.; Lavender, J.P.

    1985-01-01

    We have studied the kinetics of autologous 111 In-labelled platelets in patients with reduced platelet life span ( 111 In-labelled platelets in patients with severe thrombocytopenia. Intrasplenic platelet transit time (t) was calculated by compartmental and deconvolution analysis. In patients with a mean platelet life span of less than a few h, compartmental analysis may not be valid and so only deconvolution analysis was applied. There was a close correlation between values of t given by the two approaches (r=0.88, n=18, P<0.001). In some patients with severely reduced mean platelet life span (MPLS), the deconvolved splenic platelet clearance curves appeared to approach an asymptote, the relative magnitude of which was indicative of the irreversible extraction fraction by the spleen of incoming platelets. In othe patients with severely reduced MPLS resulting from abnormal intra-hepatic platelet destruction, the deconvolved splenic curves resembled the normal. The intrasplenic platelet transit time showed no clear relationship with other parameters. It was concluded that platelet pooling within the spleen is normal in patients with reduced platelet life span,including idiopathic thrombocytopenic purpura, even when the predominant site of destruction is the spleen, and that platelets are not delayed in transit through the spleen in preparation of their removal from the circulation and ultimate destruction. (author)

  1. (111)Indium Labelling of Recombinant Activated Coagulation Factor VII

    DEFF Research Database (Denmark)

    Nalla, Amarnadh; Buch, Inge; Sigvardt, Maibritt

    2012-01-01

    The aim of this study is to investigate whether (111)Indium-labelled recombinant FVIIa (rFVIIa) could be a potential radiopharmaceutical for localization of bleeding sources. DTPA-conjugated rFVIIa was radiolabelled with (111)In chloride. In vitro binding efficiency of (111)In-DTPA-rFVIIa to F1A2...

  2. Platelet turnover and kinetics in immune thrombocytopenic purpura: results with autologous 111In-labeled platelets and homologous 51Cr-labeled platelets differ

    International Nuclear Information System (INIS)

    Heyns A du, P.; Badenhorst, P.N.; Loetter, M.G.P.; Pieters, H.; Wessels, P.; Kotze, H.F.

    1986-01-01

    Mean platelet survival and turnover were simultaneously determined with autologous 111In-labeled platelets (111In-AP) and homologous 51Cr-labeled platelets (51Cr-HP) in ten patients with chronic immune thrombocytopenic purpura (ITP). In vivo redistribution of the 111In-AP was quantitated with a scintillation camera and computer-assisted image analysis. The patients were divided into two groups: those with splenic platelet sequestration (spleen-liver 111In activity ratio greater than 1.4), and those with diffuse sequestration in the reticuloendothelial system. The latter patients had more severe ITP reflected by pronounced thrombocytopenia, decreased platelet turnover, and prominent early hepatic platelet sequestration. Mean platelet life span estimated with 51Cr-HP was consistently shorter than that of 111In-AP. Platelet turnover determined with 51Cr-HP was thus over-estimated. The difference in results with the two isotope labels was apparently due to greater in vivo elution of 51Cr. Although the limitations of the techniques should be taken into account, these findings indicate that platelet turnover is not always normal or increased in ITP, but is low in severe disease. We suggest that this may be ascribed to damage to megakaryocytes by antiplatelet antibody. The physical characteristics in 111In clearly make this radionuclide superior to 51Cr for the study of platelet kinetics in ITP

  3. Functional alterations of human platelets following 111In labeling with different ligands and incubation media

    International Nuclear Information System (INIS)

    Mieno, Masayuki; Isaka, Yoshinori; Kimura, Kazutumi

    1990-01-01

    We studied the effects of various 111 In-water soluble chelates and incubation media on labeling efficiency of platelets and in vitro platelet aggregability. High labeling efficiency of platelets in ACD-saline was achieved with 111 In-oxine sulfate, 111 In-tropolone and 111 In-MPO (2-mercaptopyridine-N-oxide). In the condition with 4.8 x 10 6 /mm 3 platelets in ACD-plasma, 111 In-oxine-sulfate had low labeling efficiency and inconsistent labeling, while 111 In-tropolone and 111 In-MPO had high labeling efficiency. In vitro platelet aggregability (ADP 2μM) was reduced when platelets were labeled in the absence of plasma. However, there was no significant difference in platelet aggregability among 111 In-platelets labeled by three different chelates. In conclusion, to maintain aggregation activity of the platelets with relatively high labeling efficiency, the best result was obtained by using MPO or tropolone chelate in plasma at 4.8 x 10 6 /μl platelet concentration. (author)

  4. Tropolonate vs oxine 111-Indium platelet labeling: Comparison of efficiency, ultrastructure and function

    International Nuclear Information System (INIS)

    Spicer, K.M.; Lowe, L.; Gordon, L.

    1984-01-01

    Indium (I) labeled cells have proven valuable as a diagnostic tool. Recent reports indicate that Tropolonate (T) is superior to Oxine (0) as a chelator for Indium, due to its increased lipid solubility precluding cell exposure to injurious solvents. The authors examined in vivo biologic behavior of rabbit platelets (P) labeled by either IT or IO. Labeling efficiency for IT-P averaged 61% and for IO-P averaged 88%. The arachidonate induced aggregation of P labeled by both IT and 10 were normal; not significantly different from each other. Pulmonary clearance of labeled cells was determined by imaging with gamma camera and computer (256 byte, 500K count images). Average counts per pixel (ACP) wee determined at 15-minute intervals for lung (L) and blood pool (H) for 4 hours and at 24 hours. While ACP from both L and H decreased with time, in both the T and O labeled animals, the ratio of L to H (L/H) in the T rabbits was significantly lower than for O rabbits and remained so for 24 hours. At 24 hours, 0.15mg/kg oleic acid (OA) was infused via ear vein over 20 minutes. Images every 10 minutes for 2 hours were analyzed and ACP for L and H determined. The L/H for T rabbits rose 120% in an average of 46 minutes post OA insult. L/H rose an average of 44% in the O rabbits, and took longer to peak (81 min). Electron micrography revealed IO-P to have slightly more degranulation and vacuolization (thromborhexis) than the IT-P. The author conclude that while IT-P are labeled with less efficiency than the IO-P, adequate activity levels are obtained for diagnostic purposes, and ultrastructural and functional capabilities are better preserved with tropolonate labeling

  5. Platelet destruction in autoimmune thrombocytopenic purpura: kinetics and clearance of indium-111-labeled autologous platelets

    International Nuclear Information System (INIS)

    Stratton, J.R.; Ballem, P.J.; Gernsheimer, T.; Cerqueira, M.; Slichter, S.J.

    1989-01-01

    Using autologous 111 In-labeled platelets, platelet kinetics and the sites of platelet destruction were assessed in 16 normal subjects (13 with and three without spleens), in 17 studies of patients with primary autoimmune thrombocytopenic purpura (AITP), in six studies of patients with secondary AITP, in ten studies of patients with AITP following splenectomy, and in five thrombocytopenic patients with myelodysplastic syndromes. In normal subjects, the spleen accounted for 24 +/- 4% of platelet destruction and the liver for 15 +/- 2%. Untreated patients with primary AITP had increased splenic destruction (40 +/- 14%, p less than 0.001) but not hepatic destruction (13 +/- 5%). Compared with untreated patients, prednisone treated patients did not have significantly different spleen and liver platelet sequestration. Patients with secondary AITP had similar platelet counts, platelet survivals, and increases in splenic destruction of platelets as did patients with primary AITP. In contrast, patients with myelodysplastic syndromes had a normal pattern of platelet destruction. In AITP patients following splenectomy, the five nonresponders all had a marked increase (greater than 45%) in liver destruction compared to five responders (all less than 40%). Among all patients with primary or secondary AITP, there was an inverse relationship between the percent of platelets destroyed in the liver plus spleen and both the platelet count (r = 0.75, p less than 0.001) and the platelet survival (r = 0.86, p less than 0.001). In a stepwise multiple linear regression analysis, total liver plus spleen platelet destruction, the platelet survival and the platelet turnover were all significant independent predictors of the platelet count. Thus platelet destruction is shifted to the spleen in primary and secondary AITP. Failure of splenectomy is associated with a marked elevation in liver destruction

  6. Indium-111 labelled leucocyte scintigraphy in the diagnosis of inflammatory disease

    International Nuclear Information System (INIS)

    Roevekamp, M.H.

    1982-01-01

    The purpose of this study was to evaluate the diagnostic usefulness of indium-111 oxinate labelled autologous leucocytes in inflammatory disease. Chapter I provides an outline of the theoretical aspects of leucocyte labelling with indium-111 oxinate, as well as giving a description of the labelling method and scintigraphic technique and of the in-vitro and in-vivo studies performed to evaluate the method. In Chapter II details are given of the initial results obtained in a pilot study. A high false-negative rate led to modification of the labelling technique. The results obtained in patients suspected of intra-abdominal or retroperitoneal located inflammatory lesions are described in Chapter III. Chapter IV contains the description of an indium-111-leucocyte-99mTc-Sn-colloid computer-assisted subtraction technique for a better evaluation of patients suspected of an upper-abdominal inflammatory process. In Chapter V the study performed in patients after arterial reconstructive surgery is described, and the results obtained in patients suspected of an infected orthopaedic prosthesis are given in Chapter VI. Finally the characteristics of the different types of inflammatory responses is reviewed. (Auth.)

  7. Value of Indium-111m labeled platelet scans for predicting early renal allograft loss

    International Nuclear Information System (INIS)

    Shaffer, P.; Hinkle, G.; Olsen, J.; Sommer, B.; Henry, M.; Ferguson, R.

    1985-01-01

    In order to determine if In-111m labeled platelet scanning could be of use in predicting renal allograft prognosis, 41 patients (pts) thought to be at risk for graft loss were studied. In vitro labeling of platelets was performed followed by reinjection into the pt and scanning at 24 hours. The graft activity on platelet scan was compared to hepatic activity and classified as being either less than or equal to hepatic activity (NEG) or much greater than hepatic activity (POS). Results are compared to graft prognosis and are presented in this paper. The observed increase in early loss rate in the pts with POS scan over those with NEG scan was highly significant. (p .001). All pts with a POS scan were on cyclosporin A (CYA); no pt on conventional therapy (excluding CYA) had a POS scan. The authors conclude that the presence of a POS scan is a grave prognostic sign and that there appears to be a relationship between CYA, POS scan, and early graft loss

  8. Indium-111 platelet scintigraphy and two-dimensional echocardiography for detection of left ventricular thrombus: influence of clot size and age

    International Nuclear Information System (INIS)

    Seabold, J.E.; Schroeder, E.C.; Conrad, G.R.

    1987-01-01

    Two-dimensional echocardiography and indium-111 platelet scintigraphy were performed on 50 dogs to determine the influence of clot age and size on the detection of experimentally induced left ventricular mural thrombus. Thrombus was induced by apical infarction and injection of a sclerosing agent and thrombin. The animals were classified into four groups according to the time of indium-111 platelet injection after thrombus induction: Group I (17 dogs, 1/2 hour after induction; 3 dogs, before induction), Group II (12 dogs, 24 hours after induction) and Group III (12 dogs, 1 week after induction). In Group IV (six control dogs) apical infarction was produced, but thrombin was not injected; indium-111 platelets were injected 1/2 to 1 hour after infarction. The dogs were studied by indium-111 platelet scintigraphy and by two-dimensional echocardiography 1/2 to 5 hours (Group I) and 1 to 5 and up to 72 hours (Groups II to IV) after platelet administration and before death was induced. Two-dimensional echocardiography showed the best overall sensitivity for detection of acute thrombus (97%; 29 of 30). The sensitivity of indium-111 platelet scintigraphy was 86% (18 of 21) for clots greater than or equal to 0.08 ml in size, and 67% (20 of 30) for detection of all clots. Thrombus did not form in 14 dogs of Groups I to III and in 6 of 6 control dogs. The specificity of scintigraphy was 100% (20 of 20) compared with 80% (16 of 20) for echocardiography. Echocardiography was more sensitive than scintigraphy for detecting very small clots in this experimental model

  9. Left ventricular thrombi: in vivo detection by indium-111 platelet imaging and two dimensional echocardiography

    International Nuclear Information System (INIS)

    Stratton, J.R.; Ritchie, J.L.; Hamilton, G.W.; Hammermeister, K.E.; Harker, L.A.

    1981-01-01

    Indium-111 platelet imaging, which can identify sites of active intravascular platelet deposition, and two dimensional echocardiography, which can identify intracardiac masses, can both be used to detect left ventricular thrombi noninvasively. We compared these techniques in 44 men at risk for thrombi from remote transmural myocardial infarction (31 patients) or cardiomyopathy (13 patients). All 44 patients underwent platelet imaging; 35 underwent echocardiography. On platelet imaging nine patients had thrombi and onehad a possible thrombus. Of these 10 studies, none were positive at 2 hours, 5 were positive at 24 hours and all were positive 48 or 72 hours after platelet labeling. Nine of these patients underwent echocardiography, and all had an intraventricular mass. The findings on platelet scanning were negative in six patients who had positive (four patients) or equivocally positive (two patients) findings on echocardiography. All patients with thrombi detected by either noninvasive method had transmural anterior myocardial infarction with ventricular aneurysm. Of the seven patients who underwent cardiac surgery or autopsy, three had thrombi. Platelet imaging failed to identify one thrombus in a patient in whom imaging was performed only at 24 hours after labeling. There were no false positive platelet images in this group. Five of these seven patients (two with throbi, three without) underwent echocardiography; in all cases the echocardiographic findings agreed with the pathologic findings. Both platelet imaging and echocardiography detect ventricular thrombi. Platelet imaging may detect only the most hematologically active thrombi. Both techniques may help define patients at risk of embolization and may be useful for in vivo assessment of antithrombotic drugs

  10. Early diagnosis of acute postoperative renal transplant rejection by indium-111-labeled platelet scintigraphy

    International Nuclear Information System (INIS)

    Tisdale, P.L.; Collier, B.D.; Kauffman, H.M.

    1986-01-01

    A prospective evaluation of 111 In-labeled platelet scintigraphy (IPS) for the early diagnosis of acute postoperative renal transplant rejection (TR) was undertaken. The results of IPS were compared with in vitro biochemical tests, the clinical finding of graft tenderness, and combined [/sup 99m/Tc]DTPA and [ 131 I]orthoiodohippurate scintigraphy. With a sensitivity of 0.93 and a specificity of 0.95, IPS provided otherwise unavailable diagnostic information. Furthermore, postoperative IPS was a good predictor of long-term allograft survival

  11. Clinical applications of indium-111-acetylacetone-labelled blood cells

    International Nuclear Information System (INIS)

    Georgi, P.; Sinn, H.; Wellman, H.; Clorius, J.H.; Becker, W.

    1981-01-01

    A method permitting red-cell labelling with 111 In-acetylacetone was reported in 1974 for evaluating intestinal blood loss, the liver-spleen ratio and the red-cell volume. White blood cells can be tagged similarly. In white-cell labelling, simultaneous red-cell or platelet tagging is avoided. Several procedures (dextran separation and gradient centrifugations) have been combined, to develop a highly selective cell separation. In osteomyelitis it may not be as advantageous to use 67 Ga-citrate, as in inflammatory soft tissue processes. The detection of inflammatory processes with labelled leukocytes could be of great importance for the scintigraphic diagnosis of osteomyelitidies. A group of 97 patients with suspected osteomyelitis have been examined using 111 In-acetylacetone-labelled leukocytes ( 111 In-AAL) immediately following positive routine skeletal scintigraphy. Images obtained 24 h post injection usually were the most satisfactory. In the followup group of 70 patients 21 true positives, 43 true negatives, 21 false negatives and 3 false positives were observed. These findings result in a specificity of 92%, sensitivity of 50% and accuracy of 70% with 111 In-AAL for osteomyelitis. Preliminary investigations using 111 In-acetylacetone-labelled thrombocytes ( 111 In-AAT) were carried out to detect rejection of transplanted kidneys. The platelets were separated by means of additional special density gradient centrifugations but no dextran from 15-20 ml of autologous whole blood. Scans have been obtained 15 min, 2.5 h and 24 h post injection in an initial group of 10 patients. In acute rejection, a high transplant uptake has been detected, whereas patients without acute rejection showed no or only a minimum activity accumulation. Patients with chronic rejection have intermediate uptakes

  12. Detection of intra-cardiac and intra-arterial thrombi using labelled platelets

    International Nuclear Information System (INIS)

    Bernard, P.J.; Laforte, C. de

    1990-01-01

    Scintigraphy with 111 Indium labelled platelets is a powerful tool to detect platelet deposits in vessels. This quantitative and functional imaging method needs a labeling procedure which completely preserves the properties of the platelets and allows the concept of hematologically active clot. Three main groups of patients were examined. 1-91 hematologically active intra-cardiac thrombi were detected. The follow-up of 19 of them shows 5 deaths and 7 cerebral embolisms. 2-372 patients with lower limb ischemia, mainly in the case of blue toe syndrome were examined. 158 times a comparison with the surgical patterns was possible, there were 3 false positive and 9 false negative results. 3-In a group of 310 patients with transient cerebro-vascular accidents, 38 times the records were poorly significant. In 27 patients we were able to compare the morphological examinations (including platelet scintigraphy) to the anatomical findings. Sensitivity was only 64% and specificity 71%. As in the cases of intra-cardiac thrombi, the method allows the follow-up of pharmacological therapy. Platelets labelled with 111 Indium provide the means for sensitive and specific detection of hematologically active clots in cardiac and arterial pathology [fr

  13. Diagnosis of deep vein thrombosis using autologous indium-III-labelled platelets

    International Nuclear Information System (INIS)

    Fenech, A.; Hussey, J.K.; Smith, F.W.; Dendy, P.P.; Bennett, B.; Douglas, A.S.

    1981-01-01

    Forty-eight patients who had undergone surgical reduction of a fractured neck of femur or in whom deep vein thrombosis was suspected clinically were studied by ascending phlebography and imaging after injection of autologous indium-III-labelled platelets to assess the accuracy and value of the radioisotopic technique in diagnosing deep vein thrombosis. Imaging was performed with a wide-field gammacamera linked with data display facilities. Phlebography showed thrombi in 26 out of 54 limbs examined and a thrombus in the inferior vena cava of one patient; imaging the labelled platelets showed the thrombi in 24 of the 26 limbs and the thrombus in the inferior vena cava. The accumulation of indium-III at sites corresponding to those at which venous thrombi have been shown phlebographically indicates that this radioisotopic technique is a useful addition to methods already available for the detection of deep vein thrombosis. (author)

  14. Diagnosis of deep vein thrombosis using autologous indium-III-labelled platelets

    Energy Technology Data Exchange (ETDEWEB)

    Fenech, A.; Hussey, J.K.; Smith, F.W.; Dendy, P.P.; Bennett, B.; Douglas, A.S. (Aberdeen Univ. (UK))

    1981-03-28

    Forty-eight patients who had undergone surgical reduction of a fractured neck of femur or in whom deep vein thrombosis was suspected clinically were studied by ascending phlebography and imaging after injection of autologous indium-III-labelled platelets to assess the accuracy and value of the radioisotopic technique in diagnosing deep vein thrombosis. Imaging was performed with a wide-field gamma camera linked with data display facilities. Phlebography showed thrombi in 26 out of 54 limbs examined and a thrombus in the inferior vena cava of one patient; imaging the labelled platelets showed the thrombi in 24 of the 26 limbs and the thrombus in the inferior vena cava. The accumulation of indium-III at sites corresponding to those at which venous thrombi have been shown phlebographically indicates that this radioisotopic technique is a useful addition to methods already available for the detection of deep vein thrombosis.

  15. Uptake of indium-111 labelled platelets by normal, nephrotic and transplanted kidneys

    International Nuclear Information System (INIS)

    Desir, G.; Lange, R.; Smith, E.; Bia, M.; Flye, M.; Kashgarian, M.; Canganelli, A.; Ezekowitz

    1984-01-01

    To determine the role of platelets in the genesis of renal transplant (T) rejection, the authors studied 3 groups of adult patients. Group I, n=8, had normal renal function (Cr=1 +- 0.1 mg%, Mean +- SD). Group II, n=9, had nephrotic syndrome (Cr=2.4 +- 1). Group III, n=7, consisted of 5 cadaveric (C) and 2 living related donor (LRD) T. In Group II, 1 patient had received a T 4 years prior to study. Group I and II received 448 +- 101 μCi and Group III 236 +- 51 μCi of Indium-111. In Groups I and II the first image was obtained 18 +- 6 hrs after injection. In Group II the first was obtained 6 +- 2 hr after injection and 1-3 times/day thereafter for a maximum of 7 days. Renal biopsies were obtained in all patients in Group III during imaging (n=5) or within 2 - 5 days of the last image. One patient was studied twice. In Group III, 5 patients received prednisone and azothiaprine and 2 prednisone and cyclosporine. Platelet uptake index (PUI) was calculated as the ratio of uptake over the T against a reference area. Rejection was diagnosed by biopsy. In groups I and II platelet uptake was seen only in the T patient. In Group III the PUI was 1.54 +- .13 in the rejecting T (n=5), 1.42 +- .2 in the non-rejecting T (n=3), 1.62 in a LRD non-rejecting T and 1.31 (n=2) in C non-rejecting T. In the four patients studied within 5 days of T the PUI was elevated at 1.47 +- .1. The authors conclude that: 1) platelets do not accumulate in normal or nephrotic native kidneys, 2) significant uptake occurs in the first week after C and LRD whether or not rejection is present, and 3) uptake in non-rejecting kidneys cannot be ascribed to perfusion induced endothelial injury since it was present in LRD transplants

  16. Work in progress: radionuclide imaging of indium-111-labeled eosinophils in mice

    International Nuclear Information System (INIS)

    Runge, V.M.; Rand, T.H.; Clanton, J.A.; Jones, J.P.; Colley, D.G.; Partain, C.L.; James, A.E. Jr.

    1983-01-01

    Eosinophils isolated from peritoneal exudates were labeled with indium-111-oxine and injected intravenously into sensitized mice. They became localized at sites of inflammation produced by intradermal injections of schistosomal antigen or Toxocara canis larvae, whereas labeled neutrophils did not. Intense uptake of eosinophils by normal spleen, liver, and bone marrow was noted, with tracer distribution effectively complete by 5 hours after injection. Indium-111-eosinophil studies appear to be quite sensitive to parasitic inflammatory reactions; in contrast, nonspecific inflammation such as that induced by turpentine causes localization of eosinophils, but to a lesser extent. This technique may be useful in the study of parasitic and allergic disease

  17. Optimum allocation of imaging time and minimum detectable activity in dual isotope blood pool subtraction indium-111 platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Horowitz, S.F.; Goldsmith, S.J.; Fuster, V.

    1984-01-01

    Indium-111 labeled platelet imaging is a tool for detection of thrombus formation in vascular spaces. Dual isotope blood pool subtraction may help differentiate focal platelet accumulation from blood pool activity. This study used a computer model to calculate the minimum excess-to-blood pool platelet ratio (EX/BP) and the optimum dual isotope imaging times under varied conditions of lesion size. The model simulated usual human imaging doses of 500 μCi of In-111 platelets and 5mCi of Tc-99m labeled RBCs giving a reference cardiac blood pool region (100cc) of 10000 cpm for Tc-99m and 500 cpm for In-111. The total imaging time was fixed at 20 minutes, while the two isotope imaging times (TIn/TTc) were varied, as were the simulated lesion size (cc) and EX/BP. The relative error of the excess counts was calculated using propagation of error theory. At the critical level of detection, where the excess lesion counts equal 3 times the standard deviation, the optimum TIn/TTc and minimum Ex/BP were determined for each lesion size. For the smallest lesion size (0.1cc), the minimum detectable EX/BP ratio was 1.6, with the best TIn/TTC ratio of 18/2 minutes, and for large lesions, an EX/BP of 0.1, with a TIn/TTc of 16/4. This model provides an estimate of the sensitivity and optimizes imaging times in dual isotope subtraction platelet imaging. The model is adaptable to varying isotope doses, total imaging times and lesion size. This information will be helpful in future in- vivo imaging studies of intravascular thrombi in humans

  18. Identification of intracardiac thrombi in stroke patients with indium-111 platelet scintigraphy

    International Nuclear Information System (INIS)

    Kessler, C.; Henningsen, H.; Reuther, R.; Kimmig, B.; Roesch, M.

    1987-01-01

    Platelet scintigraphy (PSC) with indium-111 labelled platelets has been confirmed as an adequate method for the detection of intracardiac thrombi in patients with heart disease. We performed PSC of the heart and the neck vessels in 27 stroke patients with suspected cardiac embolism and as control on 10 patients with atherosclerotic lesions of the carotid arteries without evidence of heart disease. The carotid PSC was positive in 6 of 10 patients with carotid disease, and twice in the 27 with suspected cardiac embolism. In these 27 the PSC of the heart indicated pathological conditions 13 times. Pathological platelet accumulations could be visualized in 3 cases in the atrial space, in 9 cases in the region of the left ventricle, and once at the aortic valve. Scintigraphy was negative in all 10 patients with atherosclerosis of the neck vessels. The two-dimensional echocardiography revealed pathological findings in 8 of the 13 patients with positive heart PSC (3 with intraventricular thrombi, 3 with valvular disease, 2 with decreased ventricular contractility) and was normal in the 10 control patients. Open-heart surgery was performed in 2 patients with pathological PSC and revealed an intracardiac thrombus. Three of 4 patients with positive atrial PSC showed mitral or aortic valve disease. These results suggest that PSC can provide a valuable method for detecting cardiac thrombi in stroke patients

  19. Assessment of warfarin therapy under full dose using indium-111 platelet scintigraphy in patients with intracardiac thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Makoto; Onishi, Kenji; Fukunami, Masatake and others

    1988-12-01

    Twenty patients in whom intracardiac thrombi were detected by indium-111 platelet scintigraphy (the first platelet scintigraphy) were prospectively studied to examine the effect of warfarin therapy under full dose on the intracardiac thrombogenecity. Eleven patients (group I) who received 2-6 mg/day of warfarin and 9 patients (group II) who did not received warfarin had the second platelet scintigraphies 14-71 days after the first platelet scintigraphies. In group I, 10 platelet scintigraphies became negative and one remained positive for intracardiac thrombi after administration of warfarin, while in group II 8 platelet scintigraphies remained positive and only one changed to negative. The incidence of negative image at the second platelet scintigraphy was significantly lower in group II than that in group I. In group I, the degree of accumulation of platelets onto the surface of the thrombus (%IE), showed significant reduction (0.69+-0.48 to 0.11+-0.21) after warfarin therapy, while in group II %IE at the second scintigraphy (1.07+-1.03) were not significantly different from those at the first scintigraphy (1.13+-0.79). These results indicated that warfarin therapy under full dose inhibited the deposition of platelets on the intracardiac thrombi and thrombogenecity in the patients with intracardiac thrombi which were detected by indium-111 platelet scintigraphy.

  20. Assessment of warfarin therapy under full dose using indium-111 platelet scintigraphy in patients with intracardiac thrombi

    International Nuclear Information System (INIS)

    Yamada, Makoto; Onishi, Kenji; Fukunami, Masatake

    1988-01-01

    Twenty patients in whom intracardiac thrombi were detected by indium-111 platelet scintigraphy (the first platelet scintigraphy) were prospectively studied to examine the effect of warfarin therapy under full dose on the intracardiac thrombogenecity. Eleven patients (group I) who received 2-6 mg/day of warfarin and 9 patients (group II) who did not received warfarin had the second platelet scintigraphies 14-71 days after the first platelet scintigraphies. In group I, 10 platelet scintigraphies became negative and one remained positive for intracardiac thrombi after administration of warfarin, while in group II 8 platelet scintigraphies remained positive and only one changed to negative. The incidence of negative image at the second platelet scintigraphy was significantly lower in group II than that in group I. In group I, the degree of accumulation of platelets onto the surface of the thrombus (%IE), showed significant reduction (0.69±0.48 to 0.11±0.21) after warfarin therapy, while in group II %IE at the second scintigraphy (1.07±1.03) were not significantly different from those at the first scintigraphy (1.13±0.79). These results indicated that warfarin therapy under full dose inhibited the deposition of platelets on the intracardiac thrombi and thrombogenecity in the patients with intracardiac thrombi which were detected by indium-111 platelet scintigraphy. (author)

  1. Evaluation of aspirin therapy on intracardiac thrombi using indium-111-oxine platelet scintigraphy, two-dimentional echocardiography and left ventriculography

    International Nuclear Information System (INIS)

    Shibuya, Masanori; Irino, Tadayoshi; Yoshioka, Toshiharu; Sugimoto, Tsuyoshi; Tsuji, Kazuo; Naka, Masashi; Arai, Hidekazu.

    1984-01-01

    Left ventriculography (LVG), two-dimensional echocardiography (2-DE) and indium-111-oxine platelet scintigraphy were performed in five patients with intracardiac thrombi. Thrombi were visible in 7 sites (5 in the ventricle and 2 in the atrium) by platelet scintigraphy, in 4 sites (3 in the ventricle and 1 in the atrium) by 2-DE, and in 4 sites (4 in the ventricle) by LVG. When aspirin was administered to the patients, platelet scintigraphy had become negative for thrombi in 5 sites and false-negative for them in 2 sites. However, thrombi were detected in 6 sites after the withdrawal of aspirin. On the other hand, thrombi were detected in 4 sites by 2-DE, irrespective of the administration of aspirin. Indium-111-oxine platelet scintigraphy has proved to not only have higher sensitivity for detecting thrombi but also to be capable of observing the coagulation status of platelets on the thrombi. It is therefore considered very helpful in assessing anticoagulation therapy. (Namekawa, K)

  2. Lung transit of /sup 111/Indium-labelled granulocytes. Relationship to labelling techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saverymuttu, S.H.; Peters, A.M.; Danpure, H.J.; Reavy, H.J.; Osman, S.; Lavender, J.P. (Hammersmith Hospital, London, England)

    1983-01-01

    The early in vivo distribution of /sup 111/Indium-labelled granulocytes, recorded by dynamic imaging using a gamma camera and computer, varied according to the separation and labelling technique. Following i.v. bolus injection, 4 kinetic patterns could be identified: (A) rapid transit through the pulmonary vasculature, (B) delayed transit through the lung with clearance by about 30 min, (C) complete retention by the lung, for up to 10 min, followed by slow release over a period of 1 to 2 h, (D) delayed transit through the lung with a similar time course to (B) but with subsequent heavy liver uptake. Granulocytes labelled with /sup 111/In-tropolonate and maintained in plasma throughout the labelling procedure, whether injected as a 'pure' (separated by plasma-enriched density gradient centrifugation) or 'crude' (seprated by differential centrifugation) preparation, displayed type A kinetics, thought to most closely represent the normal behaviour of granulocytes. 'Crude' cells labelled in saline with /sup 111/In-acetylacetonate displayed type B kinetics. 'Pure' cells isolated on Percoll-saline and labelled in saline with /sup 111/In-acetylacetonate displayed type C kinetics, thought to represent granulocyte 'stimulation' and/or damage, or type D kientics, thought to represent severe damage. The importance is stressed of labelling granulocytes for kinetic studies with a technique that results in minimal alteration of cell behaviour.

  3. Survival of density subpopulations of rabbit platelets: use of 51Cr-or 111In-labeled platelets to measure survival of least dense and most dense platelets concurrently

    International Nuclear Information System (INIS)

    Rand, M.L.; Packham, M.A.; Mustard, J.F.

    1983-01-01

    The origin of the density heterogeneity of platelets was studied by measuring the survival of density subpopulations of rabbit platelets separated by discontinuous Stractan density gradient centrifugation. When a total population of 51 Cr-labelled platelets was injected into recipient rabbits, the relative specific radioactivity of the most dense platelets decreased rapidly. In contrast, that of the least dense platelets had not changed 24 hr after injection, and then decreased slowly. To distinguish between the possibilities that most dense platelets are cleared from the circulation more quickly than least dense platelets or that platelets decrease in density as they age in the circulation, the concurrent survival of least dense and most dense platelets, labelled with either 51 Cr or 111 In-labelled total platelet populations, determined concurrently in the same rabbits, are identical, calculated from 1 hr values as 100%. However, the 1-hr recovery of 111 In-labelled platelets was slightly but significantly less than that of 51 Cr-labelled platelets. Therefore, researchers studied the survival of 51 Cr-labelled least dense and 111 In-labelled most dense platelets as well as that of 111 In-labelled least dense and 51 Cr-labelled most dense platelets. Mean 1-hr recovery of least dense platelets, labelled with either isotope (78% +/- 7%, SD) was similar to that of most dense platelets, labelled with either isotope (77% +/- 8%; SD). Mean survival of least dense platelets was 47.3 +/- 18.7 hr (SD), which was significantly less than that of most dense platelets (76.1 +/- 21.6 hr; SD) (p less than 0.0025). These results indicate that platelets decrease in buoyant density as they age in the circulation and that most dense platelets are enriched in young platelets, and least dense in old

  4. In-111-oxine labeled platelet scintigraphy for detection of intracardiac and intravascular thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Hanano, Masaharu; Kimura, Michio; Ojima, Kenji [Niigata Univ. (Japan). School of Medicine

    1984-06-01

    /sup 111/In-labeled platelet scintigraphy was carried out in 20 patients suspected of thrombosis, to evaluate its efficacy for the detection of intracardiac and intravascular thrombi. Hemostatic studies including PT, aPTT, fibrinogen, FDP, platelet retention by Hellem II method, platelet aggregation induced by ADP (1 ..mu..M, 10 ..mu..M), collagen (2 ..mu..g/ml) and arachidonate (2 mM), and platelet survival were examined simultaneously. Two of these patients were also studied by fibrinogen scintigraphy labeled with sup(99m)Tc. The platelets obtained from the patients were labeled with /sup 111/In-oxine according to a method originated by Yui et al. In the platelet scintigram, positive findings were demonstrated in 9 cases : 2 left ventricular, 3 left atrial, and 4 vascular thrombi. These were in a good accordance to the findings obtained by at least one from angiography, echography and surgery. Platelet aggregation induced by 1 ..mu..M ADP was elevated in 4 of the 7 patients with positive findings and 3 of the 7 patients with negative findings. Shortened platelet survivals were observed in two of the 10 patients; dissecting aortic aneurysm and infective prosthetic valve endocarditis with hepatosplenomegaly. There was no significant difference in the platelet function and the platelet survival between the patients with positive and negative findings. It was difficult to detect thrombi by the fibrinogen scintigraphy labeled with sup(99m)Tc in the two patients studied. In conclusion, /sup 111/In-labeled platelet scintigraphy seems to be very useful to detect thrombi.

  5. Kinetics, distribution, and sites of destruction of canine blood platelets with In-111 oxine

    International Nuclear Information System (INIS)

    Loetter, M.G.; Badenhorst, P.N.; duP Heyns, A.; Van Reenen, O.R.; Pieters, H.; Minnaar, P.C.

    1980-01-01

    In five normal dogs we have studied the survival, tissue distribution, and fate of autologous platelets labeled with indium-111 oxine. The methods include blood sampling, computer-assisted scintigraphy, and whole-body profile scanning. Mean In-111-platelet recovery in the circulation was 45 +- 22.5 (s.d.) and survival 124.6 +- 10.5 h. Platelet survival curves fitted a linear function best. Initially platelets pooled rapidly in the spleen with a single exponential function, and at zero-time equilibrium (35 +- 4)% of the injected In-111 was located in this organ. Early hepatic uptake was also significant, and constituted (20 +- 4)% of total-body radioactivity. As labeled platelets disappeared from the circulation, In-111 activity in the spleen increased progressively and linearly to reach (59 +- 9)% of the body activity at 120 h. Hepatic radioactivity decreased with time but to a lesser extent than that of the heart. The results indicate that in the dog the major site of destruction of platelets is the spleen, with the liver playing a less important role

  6. Indium-111-labeled platelets: effect of heparin on uptake by venous thrombi and relationship to the activated partial thromboplastin time

    International Nuclear Information System (INIS)

    Fedullo, P.F.; Moser, K.M.; Moser, K.S.; Konopka, R.; Hartman, M.T.

    1982-01-01

    The goal of heparin thepapy in deep vein thrombosis is to prevent thrombus extension. The relationship between thrombus extension and the results of coagulation tests used to monitor heparin thepapy is unclear. To expose this relationship, we studied the effect of several heparin regimens on the accretion of indium-111-labeled platelets on fresh venous thrombi, as detected by gamma imaging, and monitored the activated partial thromboplastin time (APTT). Six dogs were treated with a 300-U/kg bolus of heparin followed by a 90-U/kg/hour heparin infusion, a dose of heparin sufficient to increase the APTT to levels greater than eight times baseline (APTT ratio); platelet accretion (thrombus imaging) occurred only after the heparin effect was reversed with protamine sulfate. Nineteen dogs were treated with a 150-U/kg bolus of heparin followed by a 4-hour, 45-U/kg/hour heparin infusion; a thrombus was demonstrated only after protamine injection in 12 (mean APTT ratio 1.3 +/- 0.19) and before protamine injection in seven. In thirteen of these 19 dogs, 30 minutes separated the platelet injection from heparin therapy, while in six this duration was less than 30 minutes. In four of these six dogs, thrombi were demonstrated before protamine therapy and at APTT ratios greater than 3.0. Finally, 10 dogs were treated with a 100-U/kg bolus followed by a 3-hour, 50-U/kg/hour heparin infusion, after which the APTT was allowed to return to baseline values spontaneously. In all 10 dogs, a thrombus was demonstrated only after cessation of the heparin infusion, and at a mean APTT ratio of 1.4 +/- 0.15 times baseline. These results suggest that, except with very early platelet injection, platelet accretion by thrombi is consistently inhibited by heparin at APTT ratios greater than 2.5

  7. Noninvasive detection of rejection of transplanted hearts with indium-111-labeled lymphocytes

    International Nuclear Information System (INIS)

    Eisen, H.J.; Eisenberg, S.B.; Saffitz, J.E.; Bolman, R.M. III; Sobel, B.E.; Bergmann, S.R.

    1987-01-01

    To determine whether cardiac transplant rejection can be detected noninvasively with indium-111 ( 111 In)-labeled lymphocytes, we studied 11 dogs with thoracic heterotopic cardiac transplants without immunosuppression and five dogs with transplants treated with cyclosporine (10 mg/kg/day) and prednisone (1 mg/kg/day). All were evaluated sequentially with gamma scintigraphy after administration of 150 to 350 muCi of autologous 111 In-lymphocytes. Technetium-99m-labeled red blood cells (1 to 3 mCi) were used for correction of radioactivity in the blood pool attributable to circulating labeled lymphocytes. Lymphocyte infiltration was quantified as the ratio of indium in the myocardium of the transplant or native heart compared with that in blood (indium excess, IE). Results were correlated with mechanical and electrical activity of allografts and with histologic findings in sequential biopsy specimens. In untreated dogs (n = 11), IE was 15.5 +/- 7.0 (SD) in transplanted hearts undergoing rejection and 0.4 +/- 1.1 in native hearts on the day before animals were killed. In dogs treated with cyclosporine and prednisone (n = 5), IE was minimal in allografts during the course of immunosuppression (0.8 +/- 0.4) and increased to 22.9 +/- 11.1 after immunosuppression was stopped. Scintigraphic criteria of rejection (IE greater than 2 SD above that in native hearts) correlated with results of biopsies indicative of rejection and appeared before electrophysiologic or mechanical manifestations of dysfunction. Thus infiltration of labeled lymphocytes in allografts, indicative of rejection, is detectable noninvasively by gamma scintigraphy and provides a sensitive approach potentially applicable to clinical monitoring for early detection of rejection and guidance for titration of immunosuppressive measures

  8. Effect of different aspirin doses on arterial thrombosis after canine carotid endarterectomy: a scanning electron microscope and indium-111-labeled platelet study

    International Nuclear Information System (INIS)

    Ercius, M.S.; Chandler, W.F.; Ford, J.W.; Swanson, D.P.; Burke, J.C.

    1984-01-01

    Although it is widely accepted that aspirin inhibits platelet aggregation in arterial thrombosis, the appropriate dosage of aspirin remains quite controversial. The purpose of this study was to determine the effect of different doses of aspirin (0.5 mg/kg vs. 10 mg/kg) on mural thrombus formation after carotid endarterectomy. Eighteen hours after oral aspirin administration, 20 endarterectomies were performed on mongrel dogs with the use of the operating microscope. Blood flow was then restored for 3 hours and the vessels were prepared for investigation with the scanning electron microscope. Ten endarterectomies were also performed on unmedicated dogs as controls. Five minutes before vessel unclamping, autologous indium-111-labeled platelets were administered intravenously, and the endarterectomized portions of the vessels were studied with a gamma counter system after harvesting. Group 1, the control group, revealed extensive mural thrombus consisting of platelet aggregates, fibrin, red blood cells, and white blood cells. Six of the 10 vessels in Group 2, premedicated with 0.5 mg of aspirin per kg, demonstrated varying amounts of mural thrombus. Group 3 (10 vessels), premedicated with 10 mg of aspirin per kg, revealed a platelet monolayer completely covering the exposed vessel wall media, with scattered white blood cells and infrequent fine fibrin strands overlying the platelet surface. The mean (+/- SD) radioactivity per group expressed as counts/minute/mm2 was: Group 1--2055.3 +/- 1905.5, log . 7.253 +/- 0.926; Group 2--1235.6 +/- 1234.3, log . 6.785 +/- 0.817; Group 3--526 +/- 433.06, log . 5.989 +/- 0.774

  9. Indium-111 labeling of leukocytes: a detrimental effect on neutrophil and lymphocyte function and an improved method of cell labelling

    International Nuclear Information System (INIS)

    Segal, A.W.; Deteix, P.; Garcia, R.; Tooth, P.; Zanelli, G.D.; Allison, A.C.

    1978-01-01

    A technique for the labeling of cells with the gamma emitter indium-111 has recently been developed. In this study the effects of the labeling procedure on some in vitro functions of human neutrophils and lymphocytes were investigated. With the standard labeling procedure, neutrophil chemotaxis was reduced to approximately 50% of normal and lymphocytes lost surface receptors and failed to respond to stimulation with phytohemagglutinin. The 8-hydroxyquinoline that is used to chelate the indium is toxic to lymphocytes; accordingly the relationship between the quantity of oxine, the chelation of indium, and cell labeling were investigated. Optimal conditions for In-111 cell labeling were established: 100 million cells in 10 ml Hanks' balanced salt solution are mixed with 5 μg of oxine in a mixture of 50 μl of ethanol and 200 μl of saline; they are incubated at 37 0 C for 10 min and then washed. Initially, neutrophils and lymphocytes appear functionally normal, but after 24 to 48 hr lymphocyte function is impaired as a result of radiation damage. This toxicity may limit studies by external scanning on the distribution and kinetics of lymphocytes labeled with In-111

  10. The effect of ibuprofen on accumulation of 111In-labeled platelets and leukocytes in experimental myocardial infarction

    International Nuclear Information System (INIS)

    Romson, J.L.; Hook, B.G.; Rigot, V.H.; Schork, M.A.; Swanson, D.P.; Lucchesi, B.R.

    1982-01-01

    To assess the ability of ibuprofen to influence the extent of platelet aggregation and leukocyte infiltration during acute myocardial infarction, autologous indium-111 ( 111 In)-labeled platelets or leukocytes were injected before 60 minutes of left circumflex coronary artery (LCx) occlusion, followed by 24 hours of reperfusion in the canine heart. Myocardial infarct size, as a percent of the area at risk, was reduced in the ibuprofen-treated group (12.5 mg/kg i.v. every 4 hours beginning 30 minutes before LCx occlusion) by 40%, from 48 +/- 4% in control animals to 29 +/- 4% in ibuprofen-treated dogs (p . 0.005). Quantification of the platelet-associated 111 In radioactivity in irreversibly injured myocardium indicated that ibuprofen did not alter the accumulation of platelets in infarcted myocardium. In contrast, leukocyte accumulation in infarcted tissue was reduced significantly. In tissue samples with 0.41-0.60 gram infarct, the infarcted/normal ratio of leukocyte radioactivity was 12 +/- 2 in control dogs and 4 +/- 1 in ibuprofen-treated dogs, which represents a 67% reduction in leukocyte accumulation in ibuprofen-treated compared with control dogs. Similar reductions were found in other gram-infarct-weight categories. Although both platelets and leukocytes accumulate in infarcted canine myocardium, ibuprofen may exert its beneficial effect on ischemic myocardium by suppressing the inflammatory response associated with myocardial ischemia and infarction

  11. Labelling of blood cells with radioactive indium-201: method, results, indications

    International Nuclear Information System (INIS)

    Ducassou, D.; Brendel, A.; Nouel, J.P.

    1978-01-01

    A modification of the method of Thakur et al. for labelling polynuclear cells with 8-hydroxyquinolein-indium-complexe utilising the water soluble sulfate of the substance was applied. The labelling procedure gave a yield over 98% with erthrocytes and over 80% with platelets and polynuclear cells using at least 1 x 10 8 plasma free cells. Functional capacity of the labelled cells remained unaltered. Injection double labelled ( 111 In, 51 Cr) red cells correlation of values for the red cell volume amounted to r = 0,98 (n=20); red cell life-spane measurements gave comparable results in 5 patients. After injecting labelled platelets a life-spane between 6,5 and 11 days was measured. Scintigraphic visualisation of pulmonary embolism was obtained 30 minutes after injecting labelled platelets. Injection of labelled polynuclear cells allows life-spane measurements as well as detection of abscesses. (author)

  12. Comparison of indium-111 platelet scintigraphy and two-dimensional echocardiography in the diagnosis of left ventricular thrombi

    International Nuclear Information System (INIS)

    Ezekowitz, M.D.; Wilson, D.A.; Smith, E.O.; Burow, R.D.; Harrison, L.H. Jr.; Parker, D.E.; Elkins, R.C.; Peyton, M.; Taylor, F.B.

    1982-01-01

    In a study comparing indium-111 platelet scintigraphy and two-dimensional echocardiography as methods of identifying left ventricular thrombi, the results obtained with both techniques were verified at surgery or autopsy in 53 patients-34 with left ventricular aneurysms, and 19 with mitral-valve disease. Left ventricular thrombi were found at surgery or autopsy in 14 of the patients with aneurysms and in none of those with mitral-valve disease. Thirteen of 53 echocardiograms (25%) were technically inadequate and excluded from the analysis. In the group with aneurysms, the sensitivity of scintigraphy in detecting thrombi was 71%, and that of echocardiography was 77%. The specificity of scintigraphy was 100%, and that of echocardiography was 93%. We conclude that indium-111 platelet scintigraphy and two-dimensional echocardiography have useful and complementary roles in the detection of left ventricular thrombi. Both these noninvasive techniques can be used to monitor therapy

  13. Detection of a prosthetic aortic valvular abscess with indium-111-labeled leukocytes

    Energy Technology Data Exchange (ETDEWEB)

    Oates, E.; Sarno, R.C.

    1988-10-01

    An unsuspected annular abscess at the base of a prosthetic aortic valve in a patient with endocarditis was identified by indium-111-labeled leukocyte scintigraphy alone. This highly sensitive and specific technique expediently demonstrated the surgically proven inflammatory focus.

  14. Detection of a prosthetic aortic valvular abscess with indium-111-labeled leukocytes

    International Nuclear Information System (INIS)

    Oates, E.; Sarno, R.C.

    1988-01-01

    An unsuspected annular abscess at the base of a prosthetic aortic valve in a patient with endocarditis was identified by indium-111-labeled leukocyte scintigraphy alone. This highly sensitive and specific technique expediently demonstrated the surgically proven inflammatory focus

  15. A comparison of two methods of labelling autologous platelets with 111In-oxine in five different species

    International Nuclear Information System (INIS)

    Christenson, J.T.; Arvidsson, D.; Thoerne, J.; Norgren, L.; Olsson, P.I.; Strand, S.E.

    1983-01-01

    Several different methods for labelling autologous platelets with 111 In-oxine have been described. However, no comparative study has been reported. In the present investigation two different labelling methods were compared in terms of labelling efficiency and platelet function in five species: human, dog, pig, rabbit and rat. One of the labelling methods, utilising among other things a serum albumin gradient separation fo platelets and incubation of 111 In-oxine in a water bath at 37 0 C, was superior in all species with significantly higher labelling efficiency and unchanged platelet function. (orig.)

  16. Evaluation of platelet thromboxane radioimmunoassay method to measure platelet life-span: Comparison with /sup 111/indium-platelet method

    International Nuclear Information System (INIS)

    Vallabhajosula, S.; Machac, J.; Badimon, L.; Lipszyc, H.; Goldsmith, S.J.; Fuster, V.

    1985-01-01

    The platelet activation during radiolabeling in vitro with Cr-51 and In-111 may affect the platelet life-span (PLS) in vivo. A new RIA method to measure PLS is being evaluated. Aspirin inhibits platelet thromboxane (TxA/sub 2/) by acetylating cyclooxygenase. The time required for the TxA/sub 2/ levels to return towards control values depends on the rate of new platelets entering circulation and is a measure of PLS. A single dose of aspirin (150mg) was given to 5 normal human subjects. Blood samples were collected for 2 days before aspirin and daily for 10 days. TxA/sub 2/ production in response to endogenous thrombin was studied by allowing 1 ml blood sample to clot at 37 0 C for 90 min. Serum TxB/sub 2/ (stable breakdown product of Tx-A/sub 2/) levels determined by RIA technique. The plot of TxB/sub 2/ levels (% control) against time showed a gradual increase. The PLS calculated by linear regression analysis assuming a 2-day lag period before cyclooxygenase recovery is 9.7 +- 2.37. In the same 5 subjects, platelets from a 50ml blood sample were labeled with /sup 111/In-tropolone in 2 ml autologous plasma. Starting at 1 hr after injection of labeled platelets, 10 blood samples were obtained over a 8 day period. The PLS calculated based on a linear regression analysis is 10.2 +. 1.4. The PLS measured from the rate of platelet disappearance from circulation and the rate of platelet regeneration into circulation are quite comparable in normal subjects. TxA/sub 2/ regeneration RIA may provide a method to measure PLS without administering radioactivity to patient

  17. Kinetics and sites of destruction of 111In-oxine-labeled platelets in idiopathic thrombocytopenic purpura: a quantitative study

    International Nuclear Information System (INIS)

    Heyns, A.D.; Loetter, M.G.; Badenhorst, P.N.; de Kock, F.; Pieters, H.; Herbst, C.; van Reenen, O.R.; Kotze, H.; Minnaar, P.C.

    1982-01-01

    Kinetics and quantification of the sites of destruction of 111 In-oxine-labeled autologous platelets were investigated in eight patients with idiopathic thrombocytopenic purpura. The mean platelet count was 17 +/- 9 X 10(9)/liter; platelets were separated by differential centrifugation and labeled with 5.6 +/- 2.5 MBq 111 In. Whole body and organ 111 In-platelet distribution was quantitated with a scintillation camera and a computer-assisted imaging system acquisition matrix. Areas of interest were selected with the computer and organ 111 In-radioactivity expressed as a percentage of whole body activity. Mean platelet survival was 49.5 +/- 29.6 hr and the survival curves were exponential. Equilibrium percentage organ 111 In-radioactivity was (normal values in parentheses): spleen 33.7 +/- 8.8 (31.1 +/- 10.2); liver 16.1 +/- 9.5 (13.1 +/- 1.3); thorax 22.8 +/- 3.7 (28.2 +/- 5.6). Percentage organ 111 In-activity at the time when labeled platelets had disappeared from the circulation was: spleen 44.5 +/- 16.4 (40 +/- 16); liver 16.0 +/- 11.5 (32.4 +/- 7.2); thorax 19.7 +/- 6.0 (17.7 +/- 10.3). Thorax activity corresponds to bone marrow radioactivity. Three patterns of platelet sequestration were evident. Three patients had mainly splenic sequestration, two mainly hepatic sequestration, and three diffuse reticuloendothelial system sequestration with a major component of platelets destroyed in the bone marrow. Splenectomy was performed in two patients. The pattern of 111 In-platelet sequestration was not predictive of response of glucocorticoid therapy or indicative of the necessity for splenectomy. Quantitative 111 In-labeled autologous platelet kinetic studies provide a new tool for the investigation of platelet disorders.U

  18. Indium-111-labelled leucocytes for localisation of abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Segal, A W; Thakur, M L; Arnot, R N; Lavender, J P [Royal Postgraduate Medical School, London (UK)

    1976-11-13

    Leucocytes from eight patients who were thought to have an abscess were labelled with indium-111 and reintroduced into the circulation. The distribution of radioactivity was followed by whole-body scanning and imaging with a gamma camera. Focal accumulations of radioactivity were observed in the lesion in the three patients with abscesses, in the lungs of a boy with bacterial endocarditis, in the knee of a woman with rheumatoid arthritis, and at the site of intramuscular injections in another patient. The use of radiolabelled cells for the detection of focal pathological processes would seem to be an important addition to conventional diagnostic methods.

  19. Technical considerations in the study of 111In-oxine labelled platelet survival patterns in dogs

    International Nuclear Information System (INIS)

    Sharefkin, J.; Rich, N.M.

    1982-01-01

    A detailed technique for labelling canine platelets with 111 In-oxine for the study of platelet survival patterns in four to six dogs at a time was developed. Useful modifications of earlier methods included splitting of the platelet rich plasma into multiple aliquots to improve pelleting efficiency at low gravity forces, use of saved platelet poor plasma to flush out injection syringes, and prompt use of commercial 111 In-oxine sources 3 to 5 minutes after mixing with Ringer's Citrate Dextrose. Avoidable pitfalls of the method included excessive lengths of incubation time in plasma free medium and loss of labelling efficacy by exposure of the chelate to iron or other metal contaminants in glassware. The method was used to study changes in platelet survival time in dogs with large synthetic arterial prostheses, and gave results in good agreement with earlier studies using 51 Cr labelled platelets

  20. 111-Indium-labelled platelets for diagnosis of acute kidney transplant rejection and monitoring of prostacyclin anti-rejection treatment

    International Nuclear Information System (INIS)

    Leithner, C.; Pohanka, E.; Schwarz, M.; Sinzinger, H.; Syre, G.

    1984-01-01

    33 patients were examined daily under a gamma camera after weekly injections of 111-In-labelled autologous platelets over a period of at least 4 weeks after transplantation. A group of 33 patients with long-term stable and well-functioning grafts served as controls. By means of a computerized recording technique, platelet trapping in the graft was measured and expressed as platelet-uptake index (PUI). The method worked well for the early diagnosis of acute rejection signified by an increase in PUI, accompanied by a shortening of platelet half life (t/2). 6 patients suffering from acute rejection received infusions of prostacyclin in addition to conventional high-dose methylprednisolone therapy. In 4 cases the PUI decreased again and an improvement in graft function was observed. Prostacyclin infusion treatment was applied also in 12 patients with histologically-proven chronic transplant rejection. Decreased platelet consumption by the graft and a temporary improvement in transplant function were achieved. We suggest that prostacyclin could enrich the possibilities of anti-rejection treatment by providing a tool for the suppression of platelet trapping in the graft. The platelet scan served as a useful method for the early detection of acute rejection, as well as the monitoring of prostacyclin anti-rejection treatment. (Autor)

  1. Indium-111-labelled leucocytes for localisation of abscesses

    International Nuclear Information System (INIS)

    Segal, A.W.; Thakur, M.L.; Arnot, R.N.; Lavender, J.P.

    1976-01-01

    Leucocytes from eight patients who were thought to have an abscess were labelled with indium-111 and reintroduced into the circulation. The distribution of radioactivity was followed by whole-body scanning and imaging with a gamma camera. Focal accumulations of radioactivity were observed in the lesion in the three patients with abscesses, in the lungs of a boy with bacterial endocarditis, in the knee of a woman with rheumatoid arthritis, and at the site of intramuscular injections in another patient. The use of radiolabelled cells for the detection of focal pathological processes would seem to be an important addition to conventional diagnostic methods. (author)

  2. Sperm-macrophage interaction in the mouse: a quantitative assay in vitro using 111indium oxine-labeled sperm

    International Nuclear Information System (INIS)

    Olive, D.L.; Weinberg, J.B.; Haney, A.F.

    1987-01-01

    The role of reproductive tract macrophages in contraception and reproductive failure has become widely recognized. However, in vitro analysis of sperm phagocytosis by macrophages has relied upon a semi-quantitative method of sperm counting that is of limited accuracy and reproducibility. We have developed an assay using murine sperm labeled with 111 indium oxine, and results indicate the labeling to be rapid and efficient. Incorporation of 111 indium into sperm increased the dose and sperm concentration and reached 90% maximal uptake after 15 min incubation, with maximal uptake occurring at 30 min. No decrease in sperm motility was noted with levels of oxine in excess of those required for significant labeling. Maximal labeling efficiency occurred in phosphate-buffered saline (PBS), with Dulbecco's modified Eagle's medium (DMEM) + 10% adult bovine serum (ABS) producing significantly less uptake. Label dissociation was detectable in PBS at room temperature, but at 37 degrees C in DMEM + 10% ABS, loss of label occurred at a rate of 23.5%/h. Addition of labeled sperm to murine macrophage monolayers under optimal conditions resulted in uptake of 111 indium by macrophages, while free label was unincorporated. Results indicated assay specificity for macrophage-limited uptake, with insignificant label uptake by nonphagocytic murine fibroblasts and better sensitivity than sperm counting. Macrophages from Bacillus Calmette-Guerin (BCG)-infected mice resulted in a decrease in sperm uptake. Female macrophages showed greater capacity for sperm uptake than those of the male mouse. These initial studies demonstrated the utility of this model system in enhancing the understanding of sperm-macrophage interaction in the female reproductive tract

  3. Reduction of indium-111 platelet deposition on Dacron vascular grafts in humans by aspirin plus dipyridamole

    International Nuclear Information System (INIS)

    Stratton, J.R.; Ritchie, J.L.

    1986-01-01

    Aspirin plus dipyridamole reduces platelet accumulation on short-term Dacron vascular grafts in man. To determine whether drug inhibition of platelet deposition is sustained on older grafts, we studied 18 men aged 41 to 87 years who had Dacron aortic bifurcation grafts in place a mean of 43.4 months (range 9.8 to 121.0) before and during short-term therapy with aspirin (325 mg tid) plus dipyridamole (75 mg tid). During both the baseline and drug studies, indium-111 ( 111 In) platelet deposition was quantitated by two techniques, standard planar imaging performed at 24, 48, and 72 hr after injection of platelets and single photon emission computed tomographic imaging performed at 24 and 72 hr after injection. All analyses were performed in a blinded fashion. On both the planar and tomographic images, platelet accumulation on the graft was quantitated by a graft/blood ratio that compared activity in the graft to simultaneously collected whole blood 111 In platelet activity. Aspirin plus dipyridamole reduced the tomographic graft/blood ratio at 24 hr (20.6 +/- 3.5 vs 17.3 +/- 2.5) (+/-SEM) and at 72 hr (29.0 +/- 4.8 vs 25.0 +/- 4.1) after injection of platelets (p = .02). Dacron vascular grafts. Similarly, the planar graft/blood ratio was reduced at 24 hr (2.7 +/- 0.5 vs 2.4 +/- 0.5), 48 hr (3.7 +/- 0.9 vs 3.1 +/- 0.7), and 72 hr (4.0 +/- 0.9 vs 3.6 +/- 0.8) (p = .04). We conclude that aspirin (325 mg tid) plus dipyridamole (75 mg tid) reduces platelet accumulation on long-term Dacron vascular grafts

  4. Radiolabeling of equine platelets in plasma with 111In-(2-mercaptopyridine-N-oxide) and their in vivo survival

    International Nuclear Information System (INIS)

    Coyne, C.P.; Kelly, A.B.; Hornof, W.J.; O'Brien, T.R.; Philp, M.S.; Lamb, J.F.

    1987-01-01

    A method is presented for the in vitro isolation and radiolabeling of equine platelets with the isotope indium 111 ( 111 In: half-life = 2.8 days, gamma = 173 keV, 89%; 247 keV, 94%). The technique described involves complexing 111 In with the lipid-soluble chelating agent, 2-mercaptopyridine-N-oxide (merc), in an aqueous medium. 111 In-merc platelet-labeling efficiencies in autologous plasma pretreated with or without ferric citrate reagent were 82 +/- 7% and 24 +/- 12%, respectively. Mean intravascular survivals of 111 In-merc-radiolabeled platelets in 8 healthy horses according to simple linear, exponential, mean, weighted-mean residual sum of squares analysis, and multiple-hit model were 5.5 +/- 0.49, 3.5 +/- 0.53, 4.5 +/- 0.18, 4.3 +/- 0.65, and 3.6 +/- 0.97 days, respectively

  5. Effects of antithrombotic drugs in patients with left ventricular thrombi: assessment with indium-111 platelet imaging and two-dimensional echocardiography

    International Nuclear Information System (INIS)

    Stratton, J.R.; Ritchie, J.L.

    1984-01-01

    Patients with left ventricular thrombi not caused by recent myocardial infarction were prospectively studied by indium-111 platelet imaging and two-dimensional echocardiography to determine the reproducibility of these techniques and the short-term effects of sulfinpyrazone (200 mg four times daily), aspirin (325 mg three times daily) plus dipyridamole (75 mg three times daily), and full-dose warfarin. At baseline, all patients underwent indium-111 platelet imaging and echocardiography, and the results were positive for thrombus. In six patients on no antithrombotic drug therapy, repeat platelet scans and echocardiographic studies at 6.0 +/- 3.3 weeks remained positive and were unchanged. In seven patients studied on sulfinpyrazone, three platelet scans became negative, two became equivocal, and two were unchanged; the presence and size of thrombus was constant by echocardiography in all seven patients. Of the six patients studied on aspirin plus dipyridamole, one platelet scan became negative, those of three became equivocal, and two were unchanged; all echocardiographic findings remained positive, but one patient had decreased thrombus size. Among four warfarin-treated patients, three had resolution of platelet deposition and one was unchanged; by echocardiography, thrombus resolved in one patient, was decreased in size in one, and was unchanged in two. We conclude that, in the absence of antithrombotic drug therapy, platelet imaging and echocardiographic findings are stable in patients with left ventricular thrombi not caused by recent myocardial infarction. Sulfinpyrazone, aspirin plus dipyridamole, and warfarin all interrupt platelet deposition in some patients with chronic left ventricular thrombi

  6. Endothelial cell labeling with indium-111-oxine as a marker of cell attachment to bioprosthetic surfaces

    International Nuclear Information System (INIS)

    Sharefkin, J.B.; Lather, C.; Smith, M.; Rich, N.M.

    1983-01-01

    Canine vascular endothelium labeled with indium-111-oxine was used as a marker of cell attachment to vascular prosthetic surfaces with complex textures. Primarily cultured and freshly harvested endothelial cells both took up the label rapidly. An average of 72% of a 32 micro Ci labeling dose was taken up by 1.5 X 10(6) cells in 10 min in serum-free medium. Over 95% of freshly labeled cells were viable by trypan blue tests and only 5% of the label was released after 1 h incubations at 37 degrees C. Labeled and unlabeled cells had similar rates of attachment to plastic dishes. Scanning electron microscopic studies showed that labeled cells retained their ability to spread on tissue culture dishes even at low (1%) serum levels. Labeled endothelial cells seeded onto Dacron or expanded polytetrafluoroethylene vascular prostheses by methods used in current surgical models could be identified by autoradiography of microscopic sections of the prostheses, and the efficiency of cell attachment to the prosthesis could be measured by gamma counting. Indium-111 labeling affords a simple and rapid way to measure initial cell attachment to, and distribution on, vascular prosthetic materials. The method could also allow measurement of early cell loss from a flow surface in vivo by using external gamma imaging

  7. Detection of intracardiac thrombi by scintiphotography with 111In-labeled autologous platelets

    International Nuclear Information System (INIS)

    Yui, Tokuo; Uchida, Tatsumi; Matsuda, Shin

    1982-01-01

    Detection of intracardiac thrombi by scintigraphy with In-111-oxine labeled autologous platelets was studied in 14 patients with various heart diseases. The results of platelet scintigraphy were compared with those of two dimensional echocardiography. In 4 of the 14 patients, the findings on platelet scintigraphy and echocardiography were both positive. Left atrial thrombi were detected in 3 patients with mitral valve disease (MVD), and left ventricular thrombus in a patient with myocardial infarction with left ventricular aneurysm (MI). The scintigraphy after antiplatelet therapy in the patient with MI did not show any radioactivity on the thrombus. In one of the 14 patients with MVD, the finding on platelet scintigraphy was positive, on the other hand echocardiography was negative. In one of the 14 patients with MVD, the finding on platelet scintigraphy was negative, on the other hand that on echocardiography was positive. The thrombus in this case may be hematologically nonactive thrombus. In-111 platelet scintigraphy is considered to be an excellent method for the diagnosis and in vivo assessment of antithrombotic therapy on intracardiac thrombosis. (J.P.N.)

  8. Appearance of acute gouty arthritis on indium-111-labeled leukocyte scintigraphy

    International Nuclear Information System (INIS)

    Palestro, C.J.; Vega, A.; Kim, C.K.; Swyer, A.J.; Goldsmith, S.J.

    1990-01-01

    Indium-111-labeled leukocyte scintigraphy was performed on a 66-yr-old male with polyarticular acute gouty arthritis. Images revealed intense labeled leukocyte accumulation in a pattern indistinguishable from septic arthritis, in both knees and ankles, and the metatarsophalangeal joint of both great toes, all of which were involved in the acute gouty attack. Joint aspirate as well as blood cultures were reported as no growth; the patient was treated with intravenous colchicine and ACTH for 10 days with dramatic improvement noted. Labeled leukocyte imaging, repeated 12 days after the initial study, revealed near total resolution of joint abnormalities, concordant with the patient's clinical improvement. This case demonstrates that while acute gouty arthritis is a potential pitfall in labeled leukocyte imaging, in the presence of known gout, it may provide a simple, objective, noninvasive method of evaluating patient response to therapy

  9. A comparison of gallium-67 citrate scintigraphy and indium-111 labelled leukocyte imaging for the diagnosis of prosthetic joint infection. Preliminary results

    International Nuclear Information System (INIS)

    McKillop, J.H.; Cuthbert, G.F.; Gray, H.W.; McKay, Iain; Sturrock, R.D.

    1982-01-01

    Preliminary experience in comparing Gallium-67 imaging in patients with a painful prosthetic joint to the findings on Indium-111 labelled leukocyte imaging is reported. In the small series of patients so far studied, no clear advantage has emerged for either Gallium-67 or Indium-111 leukocyte imaging in terms of sensitivity or specificity for joint prosthesis infection. Should a larger group confirm the preliminary findings, Gallium-67 imaging may be preferable to Indium-111 leukocyte imaging in the patient with the painful joint prosthesis, in view of the greater simplicity of the former technique

  10. 111In-labeled platelet scintigraphy and two-dimensional echocardiography for detection of left atrial appendage thrombi. Studies in a new canine model

    International Nuclear Information System (INIS)

    Vandenberg, B.F.; Seabold, J.E.; Conrad, G.R.; Kieso, R.; Johnson, J.; Fox-Eastham, K.; Ponto, J.; Bruch, P.; Kerber, R.E.

    1988-01-01

    111In-labeled platelet scintigraphy and two-dimensional echocardiography were performed in 40 dogs to determine the ability of the two techniques to detect left atrial appendage thrombi. Thrombi were induced in 33 dogs that were classified into two groups, acute or chronic, according to the time of labeled-platelet injection after thrombus induction. In the acute group (17 dogs), platelets were injected 24 hours after thrombus induction. In the chronic group (16 dogs), platelets were injected 4-8 days after thrombus induction. Sham thoracotomies were performed on seven additional control dogs who did not receive thrombin injections. Analog and blood pool-corrected 111In-labeled platelet scintigraphy images were obtained 4-72 hours later. Closed-chest two-dimensional echocardiography was performed before thoracotomy and repeated at the time of scintigraphy. The location and size of each thrombus were verified at autopsy. Two-dimensional echocardiography detected three of 17 acute (mean volume, 1.2 +/- 1.0 cc) and three of 10 chronic (mean volume, 0.4 +/- 0.3 cc; p less than 0.025) left atrial appendage thrombi. 111In-labeled platelet scintigraphy detected all 17 acute thrombi but only two of 10 chronic thrombi. The measured radioactivity levels of the excised thrombi were 1,949 +/- 1,665 cpm/clot/dose in group 1 and 228 +/- 213 cpm/clot/dose in group 2 (p less than 0.005). In this model, 111In-labeled platelet scintigraphy was able to detect acute left atrial appendage thrombi that could not be identified by two-dimensional echocardiography. Both techniques showed poor sensitivity for detection of chronic thrombi. The decline in sensitivity of 111In-labeled platelet scintigraphy for detection of older thrombi is probably due to diminished labeled-platelet incorporation

  11. Aspirin decreases platelet uptake on Dacron vascular grafts in baboons

    International Nuclear Information System (INIS)

    Mackey, W.C.; Connolly, R.J.; Callow, A.D.

    1984-01-01

    The influence of a single dose of aspirin (5.4-7.4 mg/kg) on platelet uptake on 4-mm Dacron interposition grafts was studied in a baboon model using gamma camera scanning for 111-Indium labeled platelets. In vitro assessment of platelet function after aspirin administration revealed that in the baboon, as in the human, aspirin abolished arachidonic acid-induced platelet aggregation, prolonged the lag time between exposure to collagen and aggregation, and decreased plasma thromboxane B2 levels. Aspirin also prolonged the template bleeding time. Scans for 111-Indium labeled platelets revealed that pretreatment with a single dose of aspirin decreased platelet uptake on 4-mm Dacron carotid interposition grafts. This decrease in platelet uptake was associated with a significant improvement in 2-hour graft patency and with a trend toward improved 2-week patency

  12. Characterization of a tubular flow chamber for studying platelet interaction with biologic and prosthetic materials: deposition of indium 111-labeled platelets on collagen, subendothelium, and expanded polytetrafluoroethylene

    International Nuclear Information System (INIS)

    Badimon, L.; Turitto, V.; Rosemark, J.A.; Badimon, J.J.; Fuster, V.

    1987-01-01

    A plastic (Plexiglas) chamber for evaluating platelet deposition under controlled hemodynamic conditions has been developed. The perfusion chamber has been designed to retain the cylindrical shape typical of the vasculature, to be flexible enough to accept a variety of biologic and prosthetic materials, and to simulate a broad range of physiologic flow conditions in either an ex vivo or in vitro perfusion system. Three type of surfaces were exposed to blood flowing directly from the carotid artery of a heparinized pig through the perfusion chamber: de-endothelialized pig aorta, collagen strips from rabbit Achilles tendon, and an expanded polytetrafluoroethylene material (Gore-Tex). Platelets, previously radiolabeled with indium 111 and injected into the animal, were quantified on the material surface, and the total number of deposited platelets determined for a range of blood flow rates (5 to 40 ml/min) and exposure times (0.5 to 20 minutes). The deposition rates were correlated with theory for describing the mass transport of platelets to the test surface. At the wall shear rates investigated (105 to 850 sec-1), the deposition of platelets on subendothelium was strongly dependent on the local flow conditions. Values of deposition on Gore-Tex obtained at similar flow conditions (105 to 425 sec-1) were reduced compared with that observed on subendothelium and showed a markedly weaker dependence on the shear rate. In contrast, deposition of platelets on collagen was more than an order of magnitude greater than on subendothelium and showed a dependence on flow only at the lowest flow rate studied (10 ml/min). The results indicate that collagen is much more reactive than subendothelium and Gore-Tex with respect to the growth and stability of platelet aggregates and moreover suggest that flow mechanisms for depositing platelets on various surface may be substantially different

  13. Characterization of a tubular flow chamber for studying platelet interaction with biologic and prosthetic materials: deposition of indium 111-labeled platelets on collagen, subendothelium, and expanded polytetrafluoroethylene

    Energy Technology Data Exchange (ETDEWEB)

    Badimon, L.; Turitto, V.; Rosemark, J.A.; Badimon, J.J.; Fuster, V.

    1987-12-01

    A plastic (Plexiglas) chamber for evaluating platelet deposition under controlled hemodynamic conditions has been developed. The perfusion chamber has been designed to retain the cylindrical shape typical of the vasculature, to be flexible enough to accept a variety of biologic and prosthetic materials, and to simulate a broad range of physiologic flow conditions in either an ex vivo or in vitro perfusion system. Three type of surfaces were exposed to blood flowing directly from the carotid artery of a heparinized pig through the perfusion chamber: de-endothelialized pig aorta, collagen strips from rabbit Achilles tendon, and an expanded polytetrafluoroethylene material (Gore-Tex). Platelets, previously radiolabeled with indium 111 and injected into the animal, were quantified on the material surface, and the total number of deposited platelets determined for a range of blood flow rates (5 to 40 ml/min) and exposure times (0.5 to 20 minutes). The deposition rates were correlated with theory for describing the mass transport of platelets to the test surface. At the wall shear rates investigated (105 to 850 sec-1), the deposition of platelets on subendothelium was strongly dependent on the local flow conditions. Values of deposition on Gore-Tex obtained at similar flow conditions (105 to 425 sec-1) were reduced compared with that observed on subendothelium and showed a markedly weaker dependence on the shear rate. In contrast, deposition of platelets on collagen was more than an order of magnitude greater than on subendothelium and showed a dependence on flow only at the lowest flow rate studied (10 ml/min). The results indicate that collagen is much more reactive than subendothelium and Gore-Tex with respect to the growth and stability of platelet aggregates and moreover suggest that flow mechanisms for depositing platelets on various surface may be substantially different.

  14. Use of Take-set system for radiopharmaceutical labelling: example of indium-111 labeled pentetreotide (Octreoscan) preparation

    International Nuclear Information System (INIS)

    Ben Reguiga, M.; Sinegre, M.; Besse, H.; Stievenart, J.L.; Le Guludec, D.

    2009-01-01

    The quality of indium 111 radiolabelled pentetreotide preparation (Octreoscan, Covidien) depends on several factors among which the use of a special transfer needle (Sterican) especially conceived to avoid the metal impurities introduction into the reactional medium during labelling. This device, usually provided by the supplier, can exceptionally present defects (twisted needle, folded bevel...) preventing its use for the preparation. In order to manage this risk, we propose in the present technical note an alternative labelling method, based on an adaptation of the original one and using another transfer device, the Take-setSWAN system, which permits to obtain high quality Octreoscan preparations that meet the product approval specifications. (authors)

  15. The use of autologous 111In-labelled platelets and scintigraphy to illustrate enhanced platelet activity during erection in the chacma baboon

    International Nuclear Information System (INIS)

    Dormehl, I.C.; Du Plessis, M.; Maree, M.; Bornman, M.S.; Du Plessis, D.J.

    1984-01-01

    The demonstration of thrombelastographic hypercoagulability in the penile blood during erection, and the accompanying deposition of fibrin onto the endothelial layer of the deep penile artery and trabecular surface inspired this investigation of the possible role that platelets might play in the process. The bloodpooling pattern in the penis during and after erection from electro-stimulation was studied in 9 male adult baboons (Papio ursinus) using in vivo sup(99m)Tc-labelled red blood cells and scintigraphy. Platelet activity was similarly investigated after administering autologous 111 In-labelled platelets to the baboons. The results indicate an enhanced platelet concentration with respect to blood-pooling during erection, and an entrapment of platelets after erection. (orig.) [de

  16. The use of indium-111 oxine platelet scintigraphy and survival studies in pediatric patients with thrombocytopenia

    International Nuclear Information System (INIS)

    Castle, V.P.; Shulkin, B.L.; Coates, G.; Andrew, M.

    1989-01-01

    We have utilized 111 In-labeled heterologous platelets to investigate the mechanism of thrombocytopenia in ten children. From the scintigraphic findings, platelet survival times, and clinical information, thrombocytopenia was ascribed to decreased production or to increased destruction. Two patients were found to have bone marrow production defects. Two patients with hemangiomas were studied. In one, the hemangioma was shown not to be the cause of thrombocytopenia. In the second, the hemangioma was proven the source of platelet destruction, but was much more extensive than clinically evident. In both, surgical manipulation of the hemangioma was avoided. Six additional patients had thrombocytopenia due to accelerated destruction. In four, the spleen was shown responsible. In two, however, the spleen was shown not to be responsible for the low platelet counts, and splenectomy was avoided. Thus, 111 In-platelet scintigraphy and survival studies are valuable in the classification and management of childhood thrombocytopenia. We believe that this study should be performed, when possible, in any child with thrombocytopenia where the mechanism is unclear or the therapeutic intervention involves splenectomy or resection of a hemangioma

  17. Assessment of the risk to patients from the labelling of leucocytes with indium-111

    International Nuclear Information System (INIS)

    Edwards, A.A.; Lloyd, D.C.

    1986-01-01

    Indium-111 oxine is used in diagnostic nuclear medicine to label leucocytes. A typical procedure might be to label white cells in 50 ml of blood with about 500 μCi (∼ 20 MBq) of indium-111 and return them to the body. Both theoretical and experimental information from measurements of chromosome aberrations in lymphocytes show that the labelled cells receive doses of some tens of grays, mostly delivered within one to two weeks. Much of the dose is due to short range Auger electrons. The doses to organs of the body due to circulating labelled cells are much lower. The risk to the patient thus has two components, due to the low dose irradiation of body organs and the localized high dose to the labelled cells. The former is estimated using the concept of effective dose equivalent as recommended by ICRP. An effective dose equivalent of 2 x 10 -2 Sv x mCi -1 for the above procedure was calculated making use of recent data on the distribution of the label within the body. The resulting risk of inducing a fatal cancer is calculated as about 3 x 10 -4 mCi -1 . Attempts to evaluate the risk of leukemia and lymphatic cancer due to direct irradiation of labelled leucocytes are more difficult. If cellular doses are as high as 50 Gy, cell killing can be used to argue that the risk is much lower than the whole-body risk. For lower cellular doses an argument based on the fraction of cells irradiated is used and the risk due to the labelled cells appears to be two orders of magnitude lower than the whole-body risk. 30 references, 1 figure, 3 tables

  18. Leukemic cell labeling with indium-111-oxine

    International Nuclear Information System (INIS)

    Uchida, T.; Takagi, Y.; Matsuda, S.; Yui, T.; Ishibashi, T.; Kimura, H.; Kariyone, S.

    1984-01-01

    Leukemic cells were labeled with In-111-oxine in patients with acute leukemia. In vitro labeling studies revealed that labeling efficiency reached maximum 80.8 +- 3.6% (mean +- 1SD) by 2 times washes after 20 minutes incubation time. Cell viability was assessed by trypan blue exclusion test and in vitro culture of leukemic cells, which showed no cellular damage during labeling procedure. Elution of In-111 from the labeled cells was 10.0 +- 1.2% at 12 hours after labeling. For in vivo leukemic cell kinetic studies, more than 10/sup 8/ leukemic cells separated from Ficoll-Hypacque sedimentation were labeled by 30 minutes of In-111-oxine incubation and two times washes at 37 0 C. In vivo studies were performed in 7 patients with acute myeloblastic, lymphoblastic leukemia and blastic crisis of chronic myelocytic leukemia. Labeled leukemic cells disappeared in single exponential fashion with half life of 9.6 to 31.8 hours. Total leukemic cell pool in peripheral circulation was calculated, which correlated well with peripheral leukemic cell counts (r=0.99). No relationship was observed between total leukemic cell pool and leukemic cell turnover rate. Migration patterns of labeled leukemic cells showed that pulmonary uptake was evident within 15 minutes after the infusion and returned to base-line. Splenic and hepatic uptake showed gradual increase up to 24 hours. Bone marrow accumulation was shown only in 2 cases. Presently, there are no suitable radionuclides for leukemic cell labeling. In-111-oxine labeled leukemic cells would overcome this difficulty

  19. Indium-111-labelled antimyosin antibody imaging in a patient with cardiac sarcoidosis

    International Nuclear Information System (INIS)

    Knapp, W.H.; Bentrup, A.; Ohlmeier, H.

    1993-01-01

    The aetiology of cardiac dysfunction caused by sarcoid granulomatous inflammation may be difficult to clarify, and the potential of imaging methods is limited. We report on a patient who present with acute biventricular decompensation. Pulmonary sarcoidosis was confirmed after hospitalization. Four weeks after the initiation of corticosteroid treatment, scintigraphy with indium-111-labelled antimyosin antibody Fab fragments (AMAB) revealed distinct activity accumulation in major parts of the left ventricular wall (heart-lung ratio: 1.6) 72 h following injection. There may by a role for AMAB scintigraphy in the early detection of cardiac sacroidosis. (orig.)

  20. A sensitive new method of ex vivo platelet deposition

    International Nuclear Information System (INIS)

    Badimon, L.; Fuster, V.; Dewanjee, M.K.; Romero, J.C.

    1982-01-01

    In 1978, an in vivo quantitative method of platelet aggregation based on the increment of weight of a rabbit tendon when superfused with flowing blood (3 ml/min) derived from a carotid artery of a cat and reentering the contralateral jugular vein was reported. TO increase the sensitivity of the method, researches labeled platelets with indium-111 and reinjected them after two hours; then, with a gamma counter, researches quantitated the 111 In-labeled platelets deposited on the superfused rabbit tendon. Results of the radioactivity method and of the weight method were compared. Researchers found that the 111 In-labeling of platelets was more precise and reproducible method, rendering possible the use of a small amount of blood without need for reentry into the venous system

  1. Use of indium-111-labeled white blood cells in the diagnosis of diabetic foot infections

    International Nuclear Information System (INIS)

    Zeiger, L.S.; Fox, I.M.

    1990-01-01

    The diagnosis of bone infection in the patient with nonvirgin bone is a diagnostic dilemma. This is especially true in the diabetic patient with a soft tissue infection and an underlying osteoarthropathy. The authors present a retrospective study using the new scintigraphic technique of indium-111-labeled white blood cells as a method of attempting to solve this diagnostic dilemma

  2. Comparision of indium-111 oxinate labelled autologous granulocytes with indium-111 oxinate and indium-111 chloride as abscess scanning agents

    International Nuclear Information System (INIS)

    Goedemans, W.T.; Hardemann, M.R.; Belfer, A.J.

    1980-01-01

    Bacterial abscesses were evoked in goats. Imaging of these abscesses was obtained by means of labelling autologous granulocytes with 111 In oxinate, reinjection of the cells into the animal, and scintigraphy by gamma camera one day later. Comparable imaging results, however, were obtained after intravenous of 111 In oxinate or of 111 In chloride. The gamma camera images were supported by tissue distribution studies. In the case of administration of 111 In oxinate to the goats, the radioactivity accumulated in the cell fraction of the blood to a significant extent. This did not occur in the case of plain 111 In chloride. It remained unexplained why such different accumulation in cells did not result in differences in the scintigraphic studies. Blood clearance studies supplied conclusive evidence that the granulocytes stayed in the circulation for several days following labelling with 111 In oxinate and reinjection of the cells into the animals. (orig.) [de

  3. Imaging platelet deposition on Dacron bifurcation grafts in man: Quantification by a dual-tracer method using 111In-labeled platelets and sup(99m)Tc-labeled human serum albumin

    International Nuclear Information System (INIS)

    Isaka, Yoshinari; Kimura, Kazufumi; Etani, Hideki; Uehara, Akira; Yoneda, Shotaro; Kamada, Takenobu; Kusunoki, Masahito; Kim, Teak Dong; Ohshiro, Takeshi

    1986-01-01

    A dual tracer technique using 111 In-labeled platelets and sup(99m)Tc-labeled human serum albumin was applied to evaluate the thrombogenicity of Dacron, bifurcation arterial grafts. The level of platelet accumulation over the whole of the graft was estimated from the ratio of 111 In-platelet radioactivity deposited on the vascular wall to these radioactivity circulating in the blood pool, i.e., the platelet-accumulation index (PAI). Furthermore, the PAI value was calculated for each pixel in digitized images and the PAI distribution image (PAI image) was reconstructed. Eighteen patients with DeBakey knitted Dacron bifurcation grafts and 11 normal volunteers were studied. Of the 18 patients, 11 had no graft occlusion (group I) and the remaining 7 (group II) had occlusion. The mean PAI value (+-SD) over the whole of the graft in group I was 32.6%+-33.7% as compared to -8.8%+-4.5% in the control group (P 2 =10.55; P<0.005). The method used for platelet imaging in the present study may be useful in the study of platelet reactions on Dacron arterial prostheses. (orig.)

  4. Synthesis of indium-111 mesoprotoporphyrin IX

    International Nuclear Information System (INIS)

    Lee, K.M.; Marshall, A.G.

    1981-01-01

    Indium-111 mesoprotoporphyrin IX has been prepared by refluxing suitable proportions of InCl 3 , sodium acetate, and mesoprotoporphyrin IX in glacial acetic acid. The labeled metalloporphyrin is sufficiently water-soluble for use as a scanning agent, and can also be incorporated into heme apoproteins for perturbed gamma-gamma angular correlation measurements. (author)

  5. Indium-111-labeled leukocyte scan in detection of synthetic vascular graft infection: The effect of antibiotic treatment

    International Nuclear Information System (INIS)

    Chung, C.J.; Hicklin, O.A.; Payan, J.M.; Gordon, L.

    1991-01-01

    To determine the sensitivity and specificity of the indium-111-( 111 In) labeled leukocyte scan for prosthetic vascular graft infection in patients treated with antibiotic therapy, a retrospective study was performed. Of 41 consecutive 111 In-labeled leukocyte scans performed to evaluate possible vascular graft infection, 23 scans were performed in patients treated with antibiotics. The average duration of antibiotic therapy was 21 days. Twelve positive and 11 negative scans for graft infection were found. By surgical and autopsy correlation of all positive cases, and clinical correlation (of all negative cases), there were 10 true-positive, 11 true-negative, 2 false-positive, and no false-negative scans for graft infections, for an overall sensitivity of 100% and specificity of 85%

  6. Isotope release cytotoxicity assay applicable to human tumors: the use of 111-indium

    Energy Technology Data Exchange (ETDEWEB)

    Frost, P; Wiltrout, R; Maciorowski, Z; Rose, N R

    1977-01-01

    We have demonstrated that human tumors can be labelled efficiently with the 111indium-oxine chelate. Subsequently, this isotope can be released by cytotoxic lymphoid cells. Both natural and induced cytotoxicity can be demonstrated utilizing this isotope release method. Because of the slow spontaneous release of 111indium and its efficient labelling of human tumor cells, this isotope release assay can be utilized in long-term cytotoxic assays in the study of human tumor immunology.

  7. Indium-111 granulocyte scintigraphy in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Devillers, A.; Moisan, A.; Heresbach, D.; Darnault, P.; Bretagne, J.F.

    1996-01-01

    The present paper reports our experience since 1963 concerning 111-indium labeled autologous granulocytes scanning in the assessment of inflammatory bowel diseases and in the assessment of activity in Crohn's disease and ulcerative colitis. (authors). 94 refs., 3 figs

  8. In-111 oxine autologous labeled platelets in the diagnosis of kidney graft rejection

    International Nuclear Information System (INIS)

    Martin-Comin, J.; Roca, M.; Grino, J.M.; Paradell, C.; Caralps, C.

    1983-01-01

    The usefulness of In-111 oxine labeled autologous platelets in the diagnosis of renal graft rejection was studied. The method is based on imaging of the graft area at 4, 24, 48, and 72 hours after the injection of the labeled cells. The study was done in 31 renal transplant recipients. The control group included four patients with normal renal function without evidence of rejection. No platelet uptake was observed in any of them. The study group included 22 patients with acute rejection which was confirmed histologically in 13. One case of chronic vascular type rejection of the graft tracer uptake was seen. There was a false-positive result due to a perirenal hematoma. In three patients with a non-immunological sudden impairment of renal function, no activity was detected in the graft area. We also evaluated the changes in platelet trapping throughout the study and they seemed to correlate with the response to the antirejection therapy

  9. Giant tumor thrombus in the right atrium clearly detected by /sup 111/In-oxine labeled platelet scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, T; Ishikawa, N; Satoh, A; Masuda, Y; Hiramatsu, Y; Akisada, M; Sakakibara, Y

    1985-07-01

    A 54-year-old man was admitted to hospital with a 3-month history of progressive dyspnea with coughing. A giant right atrial mass, originating from a hepatocellular carcinoma, was visualized by computed tomography, and digital subtraction angiography. The volume if the right atrial mass was increasing rapidly. It was therefore essential to determine whether this giant mass was a tumor thrombus or a multiplication of the hepatocellular carcinoma. /sup 111/In-oxine labeled platelet scintigraphy revealed active accumulation in the right atrium caused by the presence of active platelet deposition, and slight accumulation in the lung fields probably due to embolic showers originating from the tumor thrombus in the right atrium. This is the first case report showing that /sup 111/In-oxine labeled platelet scintigraphy can aid in confirming the nature of a giant tumor thrombus in the right atrium and can clarify the pathogenesis of the respiratory symptoms.

  10. Kinetics and biodistribution of In-111 platelets in patients with bone marrow transplants, refractory to platelet transfusions

    International Nuclear Information System (INIS)

    Civelek, C.; Braine, H.; Scheffel, U.; Drew, H.; Koester, A.; LaFrance, N.; Kasecamp, W.; Wagner, H. Jr.

    1984-01-01

    The kinetics and biodistribution of HLA identical In-111 labeled platelets was studied in 10 leukemic patients with bone marrow transplants refractory to HLA matched platelet transfusions. Platelet survival time was short (x-bar +- SEM =1.64 +- 0.83 days). The mean recovery (extrapolated to zero time) was 29.9%, ranging from 14.2 to 63.0%. The deposition of the In-111 platelets in the liver and spleen was quantified by the geometric mean method using anterior and posterior imaging. In 3 patients liver uptake was significantly increased. The highest hepatic accumulation of In-111 occurred 2 hrs after injection (x-bar=76 +- 6% dose (SEM); at 48 hrs 62% of the dose remained in the liver. In 7 patients the spleen was the organ with the highest labeled platelet deposition. The splenic uptake of In-111 platelets in this group correlated with the spleen size (r=+0.95). At 30 min after injection 75+-6% of the dose was found in the spleen. Splenic activity decreased to 62% after 48 hrs. At the same time, In-111 liver accumulation increased from 14 to 31%. This finding suggests that In-111 may be released from the spleen and subsequently sequestered by the liver. Two patients with high splenic uptake underwent splenectomy after the In-111 platelet study. Both benefited from splenectomy in terms of platelet survival after transfusion

  11. Kinetics and biodistribution of In-111 platelets in patients with bone marrow transplants, refractory to platelet transfusions

    Energy Technology Data Exchange (ETDEWEB)

    Civelek, C.; Braine, H.; Scheffel, U.; Drew, H.; Koester, A.; LaFrance, N.; Kasecamp, W.; Wagner, H. Jr.

    1984-01-01

    The kinetics and biodistribution of HLA identical In-111 labeled platelets was studied in 10 leukemic patients with bone marrow transplants refractory to HLA matched platelet transfusions. Platelet survival time was short (x-bar +- SEM =1.64 +- 0.83 days). The mean recovery (extrapolated to zero time) was 29.9%, ranging from 14.2 to 63.0%. The deposition of the In-111 platelets in the liver and spleen was quantified by the geometric mean method using anterior and posterior imaging. In 3 patients liver uptake was significantly increased. The highest hepatic accumulation of In-111 occurred 2 hrs after injection (x-bar=76 +- 6% dose (SEM); at 48 hrs 62% of the dose remained in the liver. In 7 patients the spleen was the organ with the highest labeled platelet deposition. The splenic uptake of In-111 platelets in this group correlated with the spleen size (r=+0.95). At 30 min after injection 75+-6% of the dose was found in the spleen. Splenic activity decreased to 62% after 48 hrs. At the same time, In-111 liver accumulation increased from 14 to 31%. This finding suggests that In-111 may be released from the spleen and subsequently sequestered by the liver. Two patients with high splenic uptake underwent splenectomy after the In-111 platelet study. Both benefited from splenectomy in terms of platelet survival after transfusion.

  12. Evaluation of indium-111 colloid for radionuclide imaging of the abdominal lymph nodes

    International Nuclear Information System (INIS)

    Vieras, F.; Hamilton, R.F.; Grissom, M.P.; Kiepffer, R.F.; Vandergrift, J.F.

    1981-01-01

    The experimental evaluation of indium-111 colloid for imaging the para-aortic lymph nodes in animals is described and preliminary results obtained in human subjects. Serial lymphatic scintigraphy performed in beagle dogs following bilateral pedal subcutaneous injections of indium-111 colloid revealed good para-aortic lymph node visualization. A normal migration pattern of indium-111 colloid was also observed in human subjects following subcutaneous injection in the feet; there was clear visualization of the ileo-inguinal and para-aortic lymph nodes. Organ distribution studies for indium-111 colloid were performed in rats following unilateral pedal subcutaneous injection in rats; these results were used for calculating radiation dose estimates to various organs. The study demonstrates the feasibility of using 111 In-colloid clinically for abdominal lymphatic scintiography for the use of sup(99m)Tc-labelled colloids results in lower radiation doses. (U.K.)

  13. Use of platelets labelled with 111In-Oxine for detection of aortic endocarditis

    International Nuclear Information System (INIS)

    Rodriguez, V.; Pulpon, L.A.; Rodriguez, E.; Marin, D.; Chamorro, J.L.; Ortiz-Berrocal, J.

    1982-01-01

    The vegetation is the most characteristic lesion of infective endocarditis. It is constituted mainly of platelets immersed in a fibrin magma, wherein microorganism nest. The damaged vascular endothelium constitutes the first stimulus for the formation of an aseptic platelet thrombus. For this reason, the use of labelled platelets permits first the external detection of formed vegetations and second, by means of serial studies, the study of the evolution of the pathological lesion under treatment with various pharmacological agent. 111 In forms a chelate with the 8-hydroxyquinolein molecule (oxine), and this chelate passes through the platelets membranes and forms a stable bond with cytoplasmic structures. The procedure used in rabbits was useful for the external detection and study of the formation of vegetation induced by infective endocarditis. The technique could be highly useful in the experimental evaluation of antiaggregant agents

  14. Differential centrifugation of leucocytes and platelets applied to 111In-leucocyte labelling

    International Nuclear Information System (INIS)

    Mountford, P.J.

    1986-01-01

    Platelet contamination of 111 In-leucocytes can be minimized by centrifugation of leucocyte-rich plasma before labelling. The differential recovery of leucocytes and platelets from centrifugation depends on various biological and physical factors. Experimental measurements have been made of the effect of some of these factors. The ratio of leucocyte-to-platelet recovery was increased by using more than one centrifugation, and by using a low relative centrifugal force (RCF). To extend the study, a method of calculating cell recovery from centrifugation was developed, based on the experimental results. Calculations indicated that this ratio was at a maximum at around 85g RCF, and was least affected by changes in the suspension medium viscosity. At 85g, leucocyte recovery was incomplete, but calculations indicated that there was a preferential recovery of granulocytes which was subsequently verified by experiment. (author)

  15. Synthesis, characterization and theranostic evaluation of Indium-111 labeled multifunctional superparamagnetic iron oxide nanoparticles

    International Nuclear Information System (INIS)

    Zolata, Hamidreza; Abbasi Davani, Fereydoun; Afarideh, Hossein

    2015-01-01

    Indium-111 labeled, Trastuzumab-Doxorubicin Conjugated, and APTES-PEG coated magnetic nanoparticles were designed for tumor targeting, drug delivery, controlled drug release, and dual-modal tumor imaging. Superparamagnetic iron oxide nanoparticles (SPIONs) were synthesized by thermal decomposition method to obtain narrow size particles. To increase SPIONs circulation time in blood and decrease its cytotoxicity in healthy tissues, SPIONs surface was modified with 3-Aminopropyltriethoxy Silane (APTES) and then were functionalized with N-Hydroxysuccinimide (NHS) ester of Polyethylene Glycol Maleimide (NHS-PEG-Mal) to conjugate with thiolated 3,6,9,15-tetraazabicyclo[9.3.1]pentadeca-1(15),11,13-triene-3,6, 9,-triacetic acid (PCTA) bifunctional chelator (BFC) and Trastuzumab antibody. In order to tumor SPECT/MR imaging, SPIONs were labeled with Indium-111 (T 1/2 = 2.80d). NHS ester of monoethyl malonate (MEM-NHS) was used for conjugation of Doxorubicin (DOX) chemotherapeutic agent onto SPIONs surface. Mono-Ethyl Malonate allows DOX molecules to be attached to SPIONs via pH-sensitive hydrazone bonds which lead to controlled drug release in tumor region. Active and passive tumor targeting were achieved through incorporated anti-HER2 (Trastuzumab) antibody and EPR effect of solid tumors for nanoparticles respectively. In addition to in vitro assessments of modified SPIONs in SKBR3 cell lines, their theranostic effects were evaluated in HER2 + breast tumor bearing BALB/c mice via biodistribution study, dual-modal molecular imaging and tumor diameter measurements

  16. Preparation of Indium Pentetate Complex (111 In-DTPA)

    International Nuclear Information System (INIS)

    Shahhosseini, S.; Farshidfar, G.R.; Najafi, R.

    2000-01-01

    There is no organometallic compound of Indium know to exist naturally in the human body. However, a number of compounds prepared with 111 In have been evaluated for localization studies. The useful radioactive decay characteristics and the suitable chemical properties of the metal ion have drawn attention of many investigators resulting in the preparation of numerous 111 In labeled compounds for potential medical applications. One of them is 111 In-DTPA complex that is used for cerebral spinal fluid studies. In the present study, DTPA has been chelated with 111 In by employing various methods and then tested for its stability in vitro during storage and in human plasma. Three methods for the preparation of 11 1In-DTPA were used. In every method, labeling efficiency and radiochemical purity were determined by chromatography systems

  17. Kidney graft rejection studies with labeled platelets and lymphocytes

    International Nuclear Information System (INIS)

    Martin-Comin, J.

    1986-01-01

    The usefulness of In-111-labelled platelets and lymphocyte scintigraphy in acute kidney graft rejection is evaluated in 155 patients. Blood cells were labelled with 100-150 uCi of In-111-oxine and reinjected. Subsequently patients were scanned once daily from 2 hours post-reinjection up to a week. The graft/contralateral area activity ratio was calculated in all scans. It is concluded that In-111-labelled platelets scintigraphy is nowadays the method of choice for acute kidney graft rejection diagnosis, especially in patients under cyclosporine immunosuppression. (author)

  18. Thrombus imaging with indium-111 and iodine-131-labeled fibrin-specific monoclonal antibody and its F(ab')2 and Fab fragments

    International Nuclear Information System (INIS)

    Rosebrough, S.F.; Grossman, Z.D.; McAfee, J.G.

    1988-01-01

    We have previously reported successful imaging of fresh (2-4 hr old) and aged (1-5 days old) canine thrombi with 131 I-labeled intact monoclonal antibody (MAb) specific for fibrin. We now report thrombus imaging with 131 I-labeled F(ab')2 and Fab and 111 In-labeled intact MAb, F(ab')2, and Fab. Indium-111-labeled F(ab')2 proved to be the best imaging agent due to less nonspecific binding in the liver than whole IgG. Image quality was improved by the higher administered dose permissible with 111 In and its better physical characteristics for imaging, compared to 131 I. Immunofluorescence of fresh human histologic sections showed intact MAb and F(ab')2 binding to thrombi, pulmonary emboli, and atherosclerotic plaques, strengthening the feasibility of clinical thrombus imaging

  19. Indium-labeled platelet uptake in rejecting renal transplants

    International Nuclear Information System (INIS)

    Chandler, S.T.; Buckels, J.; Hawker, R.J.; Smith, N.; Barnes, A.D.; McCollum, C.N.

    1983-01-01

    The uptake of 111 In autologous platelets in transplanted kidneys was measured in 16 patients shortly after operation. Each patient was then observed for two years. When transplant radioactivity had increased, despite treatment for acute rejection, the kidney was ultimately lost because of rejection

  20. Limitations in the use of indium-111-oxine-labeled leucocytes for the diagnosis of occult infection in children

    Energy Technology Data Exchange (ETDEWEB)

    Haentjens, M.; Piepsz, A.; Perlmutter-Cremer, N.; Schell-Frederick, E.; Fruehling, J.

    1987-02-01

    Fifteen children underwent scintigraphy with indium 111 (/sup 111/In)-labeled white blood cells (WBC) for the detection of a local suppuration. The procedure generally contributed to a correct diagnosis. False negative results were observed in 5 children, but in two of them positive foci were also present. The missed lesions were 2 liver abscesses, 1 lung abscess, foci of osteomyelitis and 1 pericarditis. Two cases of chronic granulomatous disease are presented in which increased leucocyte accumulation was not observed in proven instances of infection.

  1. Autoradiographic observations of the induced vascular injuries by arachidonic acid in rabbit's brain and lung using 111In-oxine labeled platelets

    International Nuclear Information System (INIS)

    Fujimoto, Tsukasa; Fukushima, Yoshiharu; Suzuki, Hidenori; Kuroiwa, Kyoko; Tanoue, Kenjiro; Yamazaki, Hiroh.

    1985-01-01

    Autoradiography using 111 In-oxine labeled autologous platelets was performed to observe the behavior of platelets in induced vascular injury by activated platelets in rabbit's brain and lung. Cerebrovascular injuries were induced by injection of arachidonic acid (AA) (0.7 mg/kg) into right internal carotid artery. Fourteen animals were pretreated with antiplatelet drug, ticlopidine (200 mg/kg) and 10 were controls. Before the AA injection, 111 In-oxine (300 μCi) labeled platelets were injected intravenously. Evans blue was given as a marker of disturbances of blood brain barrier. Sixty min after the AA injection, brains were removed and autoradiographic and electron microscopic studies were done. In the nontreated animals and some of the treated animals whose platelet aggregability was not suppressed, blue staining were seen in the cerebral hemisphere of injection side and hot radioactivity in autoradiogram were revealed in corresponding area. In the treated animals whose platelet aggregability was remarkably suppressed, no or slight blue staining or radioactivity were recognized. Only in hot radioactive area, platelet thrombi and vascular injuries were seen. Vascular injuries of lung were produced by decompression after keeping animals under hyperbalic condition (6 atomosphere absolute for 40 min). Before this procedure, 111 In-oxine labeled platelets were injected. Lungs of both 4 control and 4 decompression sickness animals were removed and autoradiographic and lightmicroscopic observations were performed. In lungs of decompression sickness animals remarkable spotty high radioactivity and prominent platelet aggregates in the vessels were seen. These findings were not seen in control animals. Our results suggested important roles of platelets in induced vascular injuries. And this autoradiographic approach seemed to be quite useful for observation of platelet's behavior in injured vessels and evaluation of antiplatelet drugs. (author)

  2. Platelet thrombosis in cardiac-valve prostheses

    International Nuclear Information System (INIS)

    Dewanjee, M.K.

    1989-01-01

    The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue valves in our one-day study in the dog model was similar (< 1% if injected In-111 platelets = 5 billion platelets). As the fibrous ingrowth covered the sewing ring, the thrombus formation decreased significantly. Only a small amount of thrombus was found on the leaflets at one month in both the dog and calf models. 38 refs., 9 figs., 5 tabs

  3. Platelet thrombosis in cardiac-valve prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Dewanjee, M.K.

    1989-01-01

    The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue valves in our one-day study in the dog model was similar (< 1% if injected In-111 platelets = 5 billion platelets). As the fibrous ingrowth covered the sewing ring, the thrombus formation decreased significantly. Only a small amount of thrombus was found on the leaflets at one month in both the dog and calf models. 38 refs., 9 figs., 5 tabs.

  4. Different cell moieties and white blood cell (WBC) integrity in In-111 labeled WBC preparations

    International Nuclear Information System (INIS)

    Saha, G.B.; Feiglin, D.H.I.; McMahon, J.T.; Go, R.T.; O'Donnell, J.K.; MacIntyre, W.J.

    1985-01-01

    Indium-111 labeled white blood cells (WBC) have become very popular in detecting inflammatory diseases. The purpose of this paper is to determine the distribution of different types of cells in WBC preparation for In-111 oxine labeling, and also to assess the histological integrity of WBC's after labeling with In-111 oxine. Forty to fifty cc of blood was collected from each patient and WBC's were separated by sedimentation and centrifugation. After labeling with In-111 oxine, an aliquot of the WBC sample was used for cell counting and a second aliquot was used for electron microscopic (EM) examination. The different cell moieties were counted, and the mean and standard deviation of twelve determinations calculated. Cells were prepared by the standard technique for electron microscopic examination and images of the cells were obtained at different magnifications (X8,000-25,000). The EM images revealed that although minimal cytoplasmic vacuolization occurred in the WBC's due to the labeling process, the overall histological integrity of the cells remained intact. The relative labeling efficiency of WBC's is greater than those of RBC's and platelets (J Nuc) Med 25:p98, 1984) and, therefore, even a comparatively low population of WBC's gives optimal imaging due to their increased tracer uptake

  5. Evaluation of three methods of platelet labelling.

    Science.gov (United States)

    Mortelmans, L; Verbruggen, A; De Roo, M; Vermylen, J

    1986-07-01

    The study of the kinetics of labelled platelets makes sense only when the platelets preserve their viability after separation and labelling. The separation and labelling procedures described in the manual of two producers of 111In-oxinate (Amersham, Mallinckrodt) have been evaluated by in vitro aggregation tests. The method of Mallinckrodt diminished the aggregation capacities of the thrombocytes. The labelled platelets with normal in vitro aggregation response (Amersham) were tested in vivo in 11 patients who underwent peripheral bypass surgery. The platelet half-life and the platelet accumulation on bypass grafts were checked one week post-operatively. Because of the poor in vivo response of both methods (exponential half-life curve and bad graft visualization), a third method was optimized in our laboratory with good in vitro and in vivo results in 12 patients.

  6. Comparison of indium-111-oxine and indium-111-acetylacetone labelled leucocytes in the diagnosis of inflammatory disease

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M.; Karimjee, S.; Saverymuttu, S.H.; Lavender, J.P. (Hammersmith Hospital, London (UK))

    1982-11-01

    /sup 111/In leucocyte scanning in a series of 132 patients has shown this technique to be a reliable and accurate means of diagnosing sepsis. Labelling with /sup 111/In oxine and with /sup 111/In acetylacetone gave similar values of sensitivity and specificity, and higher than those of ultrasound.

  7. Study of biodistribution of lipidic nanospheres charged with cis-diaminedichloroplatinum (II) and labelled with radioactive nuclei of Indium-111

    International Nuclear Information System (INIS)

    Lopez R, V.; Juarez O, C.; Medina L, A.; Perez C, E.; Garcia L, P.

    2007-01-01

    The general objective of the study was to evaluate the lipidic nanospheres biodistribution charged with cis-diaminedichloroplatinum (II) (cis-DDP) and labelled with radioactive nuclei of Indium-111 (Lip-Cis-in-111) in Wistar rats and in a tumoral model of CaCu. The conclusions were: 1. The system Lip-Cis-in-111 it presents a very fast elimination probably, to a fast recognition response of the reticuloendothelial system (RES). 2. It is planned to make modifications to the formulation to increase the quantity of the hydrophilic polymer (PEG), so that its time of residence in the blood is bigger and allow a bigger accumulation in the tumor. (Author)

  8. Detection of thrombi by 111In-oxine platelet scintigraphy

    International Nuclear Information System (INIS)

    Makino, Katsutoshi; Yamamuro, Masashi; Ichikawa, Takehiko; Futagami, Yasuo; Konishi, Tokuji; Nakano, Takeshi; Takezawa, Hideo

    1985-01-01

    For 52 patients with cardiac disease and 11 patients with vascular disease, In-111-oxine platelet scintigraphy was performed to assess its clinical usefulness for detecting thrombi. Using Hayashida's method, platelets were separated in 43 ml peripheral blood, washed and labeled with 1 mCi In-111-oxine. In addition to planar images in the anterior, 45 deg left anterior oblique and left lateral views, single photon emission computed tomography (SPECT) was performed in some cases by rotating a dual gamma camera 24 and 72 hours after labeled platelet injection. The functions of platelet and coagulability were examined 36 hours after the injection of labeled platelets. Medical therapy was not changed during this study. Intracardiac thrombi were documented in 16 of 52 cases with cardiac disease and intravascular thrombi in 10 cases with vascular disease by angiography, CT and two-dimensional echocardiography. Positive images were obtained in 10 cases with cardiac disease and in eight cases with vascular disease by scintigraphy. Therefore, sensitivity, specificity, and overall accuracy were 63 %, 100 % and 88 % in intracardiac thrombi; 80 %, 100 % and 82 % in intravascular thrombi; and totally 69 %, 100 % and 87 %, respectively. In the detection of intracardiac thrombi by scintigraphy, the sensitivity seemed to be lower and the specificity higher than those by other graphic studies. In 52 cases with cardiac disease, five out of six cases with false negative images had received antiplatelet and/or anticoagulant drugs, and in these cases, platelet and coagulation functions tended to be decreased compared with those of true positive cases or true negative cases. We conclude that positive images in scintigraphy indicate the existence of growing thrombi, and that In-111-oxine platelet scintigraphy has clinical usefulness, not only for detecting thrombi, but for estimating platelet activity and effect of medical therapy. (author)

  9. Imaging thrombus with radiolabelled monoclonal antibody to platelets

    International Nuclear Information System (INIS)

    Loutfi, I.; Peters, A.M.; Lavender, J.P.; Epenetos, A.A.

    1988-01-01

    Indium-111-hydroxyquinoline labelled platelets, though useful in the detection of thrombus, have not gained widespread use owing to the time and technical skill required for their preparation. A study was therefore conducted evaluating a new method of imaging thrombus with platelets radiolabelled with a 111 In labelled monoclonal antibody, P 256 , directed to the platelet surface glycoprotein complex IIb/IIIa. When the number of receptors occupied by P 256 was less than 3% of the total available on the platelet surface platelet function, as assessed by platelet aggregometry, was undisturbed. P 256 was radiolabelled with 111 In using diethylenetriaminepenta-acetic acid, which achieved a specific activity of 185 MBq (5 mCi)/mg. No impairment of immunoreactivity was detected at this specific activity. Platelets were labelled with radiolabelled monoclonal antibody in vitro in two patients at a receptor occupancy of 6% and in vivo - that is, by direct intravenous injection of P 256 - in six patients at a receptor occupancy of 1%. In vivo recovery and biodistribution kinetics suggested that after in vitro labelling platelets were minimally activated. The 111 In kinetics recorded after intravenous P 256 suggested rapid and efficient radiolabelling of platelets and gave no indication of platelet activation. Of the six patients who received intravenous P 256 , three had documented thrombus, tow of whom gave positive results on P 256 platelet scintigraphy. The third subject had chromic deep venous thrombosis and was scintigraphically negative. Imaging thrombus using a radiolabelled monoclonal antibody directed to platelets appears to offer great potential as a simple, non-invasive approach to the diagnosis of thrombosis. 3 refs. (Author)

  10. The use of labelled platelets in the diagnostic observation of patients after renal transplantation

    International Nuclear Information System (INIS)

    Leithner, Ch; Sinzinger, H.; Pobanka, E.; Schwarz, M.; Syre, G.; Hoefer, R.; Ludwig Boltzmann-Institut fuer Nuklearmedizin, Vienna; Vienna Univ.

    1982-01-01

    Indium 111( 111 In) labelled autologous platelets were used in the diagnostic observation of patients after renal transplantation. 75 patients were collected in 3 groups of 25 cases each. The first group consisted of patients who were examined during the first 4 weeks after transplantation. Group 2 were patients suffering from histologically proved chronic graft rejection. The 3rd group included cases with good and stable transplant function tested at least 9 months after transplantation. By means of a computerized static study the transplants were examined under the gamma-camera concerning a platelet trapping. Thereby a platelet-uptake-index(PUI) was calculated and compared with the platelet half-life-time (tsub(1/2)). This diagnostic method turned out to be suitable for early diagnosis of acute graft rejection. Hereby the PUI increased from 1.13 +- 0.11 to 1.74 +- 0.17. The further course of rejection episode manifested itself in corresponding changes of PUI. In irreversible rejections the PUI stayed in the high range or increased further. On the other hand reversible graft rejections showed a reduction of PUI, however, in the most cases not to the original basic level. The platelet tsub(1/2) exhibited a strong negative correlation with PUI. Cases suffering from chronic transplant rejection revealed significantly higher platelet trapping by the graft than patients with good and stable transplant function. (Author)

  11. Determination of cytotoxicity in vivo using 111Indium-labelled human tumor cells

    International Nuclear Information System (INIS)

    Lockshin, Arnold; Giovanella, B.C.; Kolielski, Tony; Stehlin, J.S. Jr.

    1984-01-01

    Loss of radioactivity from nude mice was determined after inoculation of human tumor cells prelabelled with ( 111 In)indium oxine ( 111 InOx). Elimination of 111 In was increased somewhat by treating the mice with diphtheria toxin (DT), which is toxic selectively for human cells compared to mice. Calcium disodium edetate (CaNa 2 EDTA), a metal chelating agent, facilitated elimination of 111 In and increased the difference in the rates of loss of radioactivity from mice bearing viable compared to DT-killed cells. (author)

  12. Evaluation of three methods of platelet labelling

    International Nuclear Information System (INIS)

    Mortelmans, L.; Verbruggen, A.; Roo, M. de; Vermylen, J.

    1986-01-01

    The study of the kinetics of labelled platelets makes sense only when the platelets preserve their viability after separation and labelling. The separation and labelling procedures described in the manual of two producers of 111 In-oxinate (Amersham, Mallinckrodt) have been evaluated by in vitro aggregation tests. The method of Mallinckrodt diminished the aggregation capacities of the thrombocytes. The labelled platelets with normal in vitro aggregation response (Amersham) were tested in vivo in 11 patients who underwent peripheral bypass surgery. The platelet half-life and the platelet accumulation on bypass grafts were checked one week post-operatively. Because of the poor in vivo response of both methods (exponential half-life curve and bad graft visualization), a third method based on that described by W.A. Heaton et al. 1979 was optimized in the authors' laboratory with good in vitro and in vivo results in 12 patients. (author)

  13. Cellular basis for accumulation of 111In-labeled leukocytes and platelets in rejecting cardiac allografts: concise communication

    International Nuclear Information System (INIS)

    Wang, T.S.; Oluwole, S.; Fawwaz, R.A.; Wolff, M.; Kuromoto, N.; Satake, K.; Hardy, M.A.; Alderson, P.O.

    1982-01-01

    Biodistribution and imaging studies in rats showed that 111 In-labeled leukocytes and platelets accumulate progressively with time after transplantation in cardiac allografts undergoing rejection, but do not accumulate in normal syngeneic heart grafts. Maximum heart allograft-to-blood ratios of 9:1 were obtained, and allograft-to-native heart ratios of 17:1. Microscopic studies of the rejecting cardiac allografts showed that histologic findings paralleled the cellular changes predicted by the radionuclide studies. Intravenously administered 67 Ga citrate and /sup 99m/Tc sulfur colloid failed to show significant accumulation in rejecting grafts. The findings suggest that cellular rejection, rather than nonspecific inflammatory changes, is the primary basis for accumulation of 111 In leukocytes and platelets in rejecting cardiac allografts

  14. Cellular basis for accumulation of In-111-labeled leukocytes and platelets in rejecting cardiac allografts: concise communication

    International Nuclear Information System (INIS)

    Wang, T.S.T.; Oluwole, S.; Fawwaz, R.A.; Wolff, M.; Kuromoto, N.; Satake, K.; Hardy, M.A.; Alderson, P.O.

    1982-01-01

    Biodistribution and imaging studies in rats showed that In-111-labeled leukocytes and platelets accumulate progressively with time after transplantation in cardiac allografts undergoing rejection, but do not accumulate in normal syngeneic heart grafts. Maximum heart allograft-to-blood ratios of 9:1 were obtained, and allograft-to-native heart ratios of 17:1. Microscopic studies of the rejecting cardiac allografts showed that histologic findings paralleled the cellular changes predicted by the radionuclide studies. Intravenously administered Ga-67 citrate and Tc-99m sulfur colloid failed to show significant accumulation in rejecting grafts. The findings suggest that cellular rejection, rather than nonspecific inflammatory changes, is the primary basis for accumulation of In-111 leukocytes and platelets in rejecting cardiac allografts

  15. Indium-111 octreotide uptake in the surgical scar

    Energy Technology Data Exchange (ETDEWEB)

    Degirmenci, B.; Bekis, R.; Durak, H.; Derebeck, E. [Dokuz Eylul Univ., Izmir (Turkey). Dept. of Nuclear Medicine; Sen, M. [Dokuz Eylul Univ., Izmir (Turkey). Dept. of Radiation Oncology

    1999-07-01

    Indium-111 octreotide uptake has been reported in various somatostatin receptor positive tumors, granulomas and autoimmune diseases in which activated leucocytes may play a role, subcutaneous cavernous hemangioma and angiofibroma. We present Indium-111 octreotide uptake in a surgical abdominal scar tissue 1.5 to 6 months after surgery in a patient who had been treated for recurrent carcinoid tumor in the rectosigmoid junction. Indium-111 octreotide uptake in a surgical scar may be related to the binding to somatostatin receptors in the activated lymphocytes and fibroblasts that is previously reported. (orig.) [German] In verschiedenen Somatostatinrezeptor-positiven Tumoren, Granulomen, bei Autoimmunerkrankungen, in denen aktivierte Leukozyten eine Rolle spielen, subcutanen kavernoesen Hammangiomen und Angiofibromen wurde ueber die Anreicherung von Indium-111-Oktreotid berichtet. Wir berichten ueber die Anreicherung von Indium-111-Oktreotid in einer chirurgischen Narbe ueber dem Abdomen nach 1,5 und 6 Monaten bei einem Patienten mit einem Rezidiv-Karzinoid im rektosigmoidalen Uebergang. Die Anreicherung von Indium-111-Oktreotid in chirurgischen Narbengewebe koennte in Zusammenhang stehen mit einer Bindung an Somatostationrezeptoren in aktivierten Lymphozyten und Fibroblasten, ueber die schon berichtet wurde. (orig.)

  16. Study of the cerebro-spinal fluid circulation indium 111 labelled DTPA. Report of 300 cases

    International Nuclear Information System (INIS)

    Moreau, R.; Askienazy, S.; Mathieu, E.; Moretti, J.-L.

    1976-01-01

    A study of the C.S.F. circulation by intrathecal injection of radioactive tracers is a usual technique of neurological exploration. Indium-111 DTPA has numerous advantages for this type of study. It is a chelating agent, the renal clearance of which is rapid and which has no toxicity at the dose injected. Indium-111 is a cyclotron product with a half-life (2.8 days) compatible with the duration of the examination. Finally the dose of radioactivity delivered by this isotope is less than that of iodine 131, Technetium 99m, and ytterbium 169. In normal subjects after injection by the lumbar route, the average biological half-life measured by external counting lies between 20 and 28 hours. A study of the circulation of the C.S.F. is particularly useful in patients suspected of hydrocephalus. It permits finer diagnosis and shows the indication and type of by pass operation that may be necessary. An increase in the biological half-life of indium 111-DTPA seems to be a good indication for such an operation. An experience of 300 patients has shown the interest of the use of Indium 111-DTPA which now seems to be the best radio-isotope for the study of the subarachnoid space [fr

  17. Use of Take-set system for radiopharmaceutical labelling: example of indium-111 labeled pentetreotide (Octreoscan) preparation; Utilisation du systeme Take-set pour le radiomarquage des medicaments radiopharmaceutiques: exemple de la preparation du pentetreotide marque a l'indium 111 (Octreoscan)

    Energy Technology Data Exchange (ETDEWEB)

    Ben Reguiga, M.; Sinegre, M. [Hopital Beaujon, Unite de Radiopharmacie, Service de Pharmacie-toxicologie, 92 - Clichy (France); Besse, H.; Stievenart, J.L.; Le Guludec, D. [Hopital Beaujon, Service de Medecine Nucleaire92 - Clichy (France)

    2009-09-15

    The quality of indium 111 radiolabelled pentetreotide preparation (Octreoscan, Covidien) depends on several factors among which the use of a special transfer needle (Sterican) especially conceived to avoid the metal impurities introduction into the reactional medium during labelling. This device, usually provided by the supplier, can exceptionally present defects (twisted needle, folded bevel...) preventing its use for the preparation. In order to manage this risk, we propose in the present technical note an alternative labelling method, based on an adaptation of the original one and using another transfer device, the Take-setSWAN system, which permits to obtain high quality Octreoscan preparations that meet the product approval specifications. (authors)

  18. Radioimmunological imaging of metastatic prostatic cancer with 111indium-labeled monoclonal antibody PAY 276

    International Nuclear Information System (INIS)

    Babaian, R.J.; Murray, J.L.; Lamki, L.M.

    1987-01-01

    A total of 25 patients with histologically proved adenocarcinoma of the prostate, whose disease was staged clinically as D2 by appropriate radiographic and nuclear medicine studies, received increasing doses of PAY 276, an antiprostatic acid phosphatase monoclonal antibody for radioimmunological imaging. The patients were divided into 5 groups of 5. Groups 1 through 5 received an infusion of 5, 10, 20, 40 or 80 mg. monoclonal antibody, respectively, 1 mg. of which was labeled to 5 mCi. of 111 indium, while stable monoclonal antibody was added to achieve the desired antibody concentration. No patient had an allergic reaction, and no significant change in serial hemoglobin levels, platelet count, chemistry profile or results of urinalyses was noted. The monoclonal antibody scan visualized at least 1 lesion in 19 of 25 patients (76 per cent): 4 in groups 1 and 2, and all 15 in groups 3 to 5. With results of conventional radiography and bone scintigraphy considered definitive for metastases, monoclonal antibody scans detected 7 of 32 metastases (21.8 per cent) in group 3 (20 mg.), 31 of 58 (53.4 per cent) in group 4 (40 mg.) and 101 of 134 (75.4 per cent) in group 5 (80 mg). In group 5 the incidence of false positive and false negative scans was 2.3 per cent (3 of 132) and 24.6 per cent (33 of 134), respectively. The detection of metastatic lesions increased as the concentration of unlabeled monoclonal antibody increased. Radioimmunological imaging of prostatic cancer with antiprostatic acid phosphatase monoclonal antibody seems to be feasible

  19. Increased blood clearance rate of indium-111 oxine-labeled autologous CD4+ blood cells in untreated patients with Hodgkin's disease

    International Nuclear Information System (INIS)

    Grimfors, G.; Holm, G.; Mellstedt, H.; Schnell, P.O.; Tullgren, O.; Bjoerkholm, M.

    1990-01-01

    Untreated patients with Hodgkin's disease (HD) have a blood T-lymphocytopenia mainly caused by a reduction of the CD4+ subset. Indirect support for a sequestration of T cells in the spleen and tumor-involved lymphoid tissue has accumulated. To test the hypothesis that the blood CD4 T-lymphocytopenia in patients with HD is caused by an altered lymphocyte traffic, 12 untreated HD patients and five in complete clinical remission (CCR) were studied. Blood lymphocytes were collected by leukapheresis and gradient centrifugation, and were further purified by an adherence step. The cells were labeled with indium-111 oxine and reinfused intravenously into the patient. The radioactivity of CD4+ and CD8+ blood lymphocytes separated by immunoabsorption was measured from serial blood samples. CD4+ cells were eliminated more rapidly in untreated patients than patients in CCR. Repeated gamma camera imaging after autotransfusion of indium-111 oxine labeled cells demonstrated an accumulation of radioactivity in tumor-involved tissue of untreated patients. These findings support the concept of an enhanced elimination of CD4+ cells in patients with active HD that may contribute to the observed blood T-lymphocytopenia and may reflect a biologic response to the tumor

  20. An optimized antibody-chelator conjugate for imaging of carcinoembryonic antigen with indium-111

    International Nuclear Information System (INIS)

    Sumerdon, G.A.; Rogers, P.E.; Lombardo, C.M.; Schnobrich, K.E.; Melvin, S.L.; Tribby, I.I.E.; Stroupe, S.D.; Johnson, D.K.; Hobart, E.D.

    1990-01-01

    A monoclonal antibody to carcinoembryonic antigen showing minimal cross-reactivity with blood cells and normal tissues was derivatized with benzylisothiocyanate derivatives of EDTA and DTPA. Seven chelators per immunoglobulin could be incorporated without loss of immunoreactivity. The resulting conjugates, labeled with indium-111, showed low liver uptake in animals. A cold kit, comprising the DTPA conjugate at a molarity of antibody bound chelator exceeding 1 x 10 -4 M, gave radiochemical yields of indium labeled antibody of ≥ 95% and was stable for 1 yr. (author)

  1. Indium-111 leukocyte imaging in appendicitis

    International Nuclear Information System (INIS)

    Navarro, D.A.; Weber, P.M.; Kang, I.Y.; dos Remedios, L.V.; Jasko, I.A.; Sawicki, J.E.

    1987-01-01

    Indium- 111 -labeled leukocyte scintigraphy was applied to the diagnosis of acute appendicitis. Thirty-two patients observed in the hospital for possible appendicitis were prospectively studied. Scanning was done 2 hr after radiopharmaceutical injection. Thirteen scans were positive for acute appendicitis, and all but one were confirmed at laparotomy. In addition, two cases of colitis and two cases of peritonitis were detected. Of 15 negative studies, 11 had a benign course. Four patients with negative studies had laparotomy; two were found to have appendicitis and two had a normal appendix. Of 14 proven cases of appendicitis, 12 scans were positive for appendicitis with one false-positive scan, providing a sensitivity of 86%. Specificity was 93%: all negative cases except one had negative scans. Overall accuracy was 91% (29 of 32), comparing favorably with the accepted false-positive laparotomy rate of 25%. Use of In- 111 -labeled leukocyte scintigraphy serves to reduce the false-positive laparotomy rate and to shorten the clinical observation time in patients with acute appendicitis

  2. Evaluation of indium-111-labeled antifibrin monoclonal antibody for the diagnosis of venous thrombotic disease

    International Nuclear Information System (INIS)

    De Faucal, P.; Peltier, P.; Planchon, B.; Dupas, B.; Touze, M.D.; Baron, D.; Scaible, T.; Berger, H.J.; Chatal, J.F.

    1991-01-01

    The potential advantage of using 111 In-antifibrin ( 111 In-AF) monoclonal antibody for the diagnosis of deep venous thrombosis (DVT) was studied in 44 patients with suspected DVT (27 underwent heparin therapy before 111 In-AF injection). All patients had contrast venography (considered as the gold standard) and 111 In-AF scintigraphy within 24 hr. Two to 3 mCi of 111 In-AF were injected intravenously, and planar scintigraphy of the limbs was recorded within 10 min (17 times), 3 hr (44 times), and 18 hr (39 times). Indium-111-AF images were then interpreted without knowledge of the results of the other examinations. The DVT diagnostic accuracy of 111 In-AF was greater when interpretation was based on images recorded at different time periods after injection. Indium-111-AF sensitivity for diagnosis of DVT was 85% (29/34) and was not apparently decreased by heparin therapy. None of the 10 patients with negative contrast venography had a positive 111 In-AF scan. The results demonstrate the importance of recording serial images and the excellent accuracy of 111 In-AF for diagnosing DVT

  3. Utility of the indium 111-labeled human immunoglobulin G scan for the detection of focal vascular graft infection

    International Nuclear Information System (INIS)

    LaMuraglia, G.M.; Fischman, A.J.; Strauss, H.W.; Keech, F.; Wilkinson, R.; Callahan, R.J.; Khaw, B.A.; Rubin, R.H.

    1989-01-01

    The ability to diagnose and localize vascular graft infections has been a major challenge. Recent studies in animal models and humans with focal bacterial infection have shown that radiolabeled, polyclonal, human immunoglobulin G accumulates at the site of inflammation and can serve as the basis for an imaging technique. This study investigated this new technique for the diagnosis and localization of vascular graft infections. Twenty-five patients with suspected vascular infections involving grafts (22), atherosclerotic aneurysms (2), and subclavian vein thrombophlebitis (1) were studied. Gamma camera images of the suspected area were obtained between 5 and 48 hours after intravenous administration of 1.5 to 2.0 mCi (56 to 74 mBq) of indium 111-labeled, human, polyclonal immunoglobulin G. Scan results were interpreted without clinical information about the patient and were subsequently correlated with surgical findings, other imaging modalities, and/or clinical follow-up. In 10 of 10 patients found to have positive scan results, localized infections were confirmed at the involved sites. In 14 of 15 patients whose scan results were interpreted as negative, no vascular infections were identified at follow-up. The patient with false-negative results and recurrent bacteremia from an aortoduodenal fistula was found to have a negative scan outcome at a time when his disease was quiescent. These data suggest that nonspecific, human, indium 111-labeled immunoglobulin G scanning can be a useful noninvasive means of localizing vascular infections

  4. Rapid, high-efficiency labeling of leukocytes with In-111 after hemolytic removal of erythrocytes

    International Nuclear Information System (INIS)

    Karesh, S.M.; Henkin, R.E.

    1985-01-01

    During the labeling of leukocytes with Indium-111, conventional methodology involves separation and washing to remove red cells. This technique results in the loss of a significant number of leukocytes. Citrated whole blood of ten normal volunteers was studied for an alternate labeling method following sedimentation for 30 to 45 minutes and low speed centrifugation of the leukocyte-rich plasma. The average labeling for these ten volunteers by Indium-111 was 90% versus 60% by the older technique. Viability as measured by the trypan blue exclusion test was greater than 95%, WBC losses were essentially zero, and no WBC clumping was observed. Eighteen patients referred for leukocyte imaging were studied by this method. In this patient population, there was 91% labeling with viability greater than 95% and no evidence of clumping. Less than 5% RBC's were noted in any lot. Indium-111 WBC activity 20 minutes post injection averaged 79% of whole blood activity. This modification results in decreased losses of white cells, reduces preparation time to less than 2 hours, and significantly improves the labeling efficiency of the final product. Liver/spleen ratios and image quality were unchanged from the original method

  5. In vitro isotopic determination of diffusion volumes by transferrin labelled with indium 111. study of the correlation with SARI 125; Determination isotopique in vitro de volumes de diffusion par la transferrine marquee a l'indium 111. Etude de la correlation avec la SARI 125

    Energy Technology Data Exchange (ETDEWEB)

    Porot, C.L. [CHU Jean-Minjoz, Service de medecine nucleaire, 25 - Besancon (France); Angoue, O.R. [CHU Jean-Minjoz, laboratoire de biophysique et statistiques, 25 - Besancon (France); Berthetc, L.O. [CHU Jean-Minjoz, 25 - Besancon (France); Ungureanu, C.O.; Boulahdour, H.A.

    2010-07-01

    Serum albumin labeled with iodine 125 (S.A.R.I. 125) is the reference tracer used in measuring isotopic plasma volume. It has been causing a suspension of manufacturing leading to a supply disruption and resulting in the search for an alternative to measure plasma volume under consideration for measuring blood volume. Plasma transferrin labeled with indium-111 (Tf-{sup 111}In) is a potentially useful marker. To this end, we assessed the level of activity to be administered to determine a volume of distribution. The study of the correlation between the volume of distribution values obtained with S.A.R.I. 125 and Tf-{sup 111}In was then performed. Tf is an autologous protein which the labelling is easy and stable. Tf-{sup 111}In is a valid alternative to the S.A.R.I. 125 for measuring the plasma volume. The activity required for this examination shall not exceed 100 micro curies. (N.C.)

  6. Colonic localization of indium-111 labeled leukocytes in active Behcet's disease

    International Nuclear Information System (INIS)

    Harre, R.G.; Conrad, G.R.; Seabold, J.E.

    1988-01-01

    A patient with known Behcet's disease demonstrated intense colonic localization of In-111 labeled leukocytes. Gastrointestinal involvement had not been previously manifested, but extensive colonic inflammation was documented by endoscopy. This case illustrates the utility of In-111 labeled leukocyte imaging for detecting active bowel disease in a debilitated patient with documented Behcet's vasculitis

  7. The use of indium-111-labeled platelets in the management of renal transplant patients

    International Nuclear Information System (INIS)

    Sinzin ger, H.F.; Leithner, C.W.

    1985-01-01

    The authors begin by explaining the role of pltelets in the pathogenesis of renal transplant rejection. During the sudden and severe immunilogical event that characterizes hyperacute rejection, when the endothelium is damaged, platelets accumulate on its surface. In chronic graft rejection, platelets liberate a growth factor that stimulates proliferation of arterial smooth muscle cells, and therefore might initiate and promote obliterative arteriopathy. In the opinion of these authors, platelet scanning has contributed greatly to the understanding of the role of platelets in the different kinds of graft rejection. The important remaining question is whether platelets deposit before, concomitantly with, or after infiltration by lymphocytes

  8. Entrapment of platelets in the penis during and after erection

    International Nuclear Information System (INIS)

    Bornman, M.S.; Du Plessis, D.J.; Dormehl, I.C.; Du Plessis, M.; Jacobs, D.J.; Maree, M.

    1986-01-01

    Because of the development of hypercoagulability and the deposition of fibrin in the penis during erection a study of the possible role of platelets in this process was undertaken. Platelets response was studied in 9 adult chacma baboons (Papio ursinus) using autologous in vitro indium-111-labelled platelets and sequential scintigraphy of the penis during erection. The blood pooling pattern was obtained using in vivo technetium-99m-labelled red cells in a similar investigation. A statistically significant retention of platelets occured during and after erection, wich could not be attributed to blood pooling (P < 0,05). Entrapment of platelets could lead to enhanced activation, and might play a significant role in hypercoagulability and fibrin deposition during erection. Therefore platelets could be an important factor in the pathogenesis of ageing impotence

  9. 111In platelet imaging of left ventricular thrombi. Predictive value for systemic emboli

    International Nuclear Information System (INIS)

    Stratton, J.R.; Ritchie, J.L.

    1990-01-01

    To determine whether a positive indium 111 platelet image for a left ventricular thrombus, which indicates ongoing thrombogenic activity, predicts an increased risk of systemic embolization, we compared the embolic rate in 34 patients with positive 111 In platelet images with that in 69 patients with negative images during a mean follow-up of 38 +/- 31 (+/- SD) months after platelet imaging. The positive and negative image groups were similar with respect to age (59 +/- 11 vs. 62 +/- 10 years), prevalence of previous infarction (94% vs. 78%, p less than 0.05), time from last infarction (28 +/- 51 vs. 33 +/- 47 months), ejection fraction (29 +/- 14 vs. 33 +/- 14), long-term or paroxysmal atrial fibrillation (15% vs. 26%), warfarin therapy during follow-up (26% vs. 20%), platelet-inhibitory therapy during follow-up (50% vs. 33%), injected 111 In dose (330 +/- 92 vs. 344 +/- 118 microCi), and latest imaging time (greater than or equal to 48 hours in all patients). During follow-up, embolic events occurred in 21% (seven of 34) of patients with positive platelet images for left ventricular thrombi as compared with 3% (two of 69) of patients with negative images (p = 0.002). By actuarial methods, at 42 months after platelet imaging, only 86% of patients with positive images were embolus free as compared with 98% of patients with negative images (p less than 0.01)

  10. Early diagnosis of rejection reactions by means of 111In-oxine-labelled thrombocytes

    International Nuclear Information System (INIS)

    Kolbe, H.; Sinzinger, H.; Angelberger, P.; Leithner, C.; Oesterreichische Studiengesellschaft fuer Atomenergie G.m.b.H., Seibersdorf. Inst. fuer Chemie)

    1980-01-01

    According to a modified labelling method thrombocytes were treated with 111 In-oxine. In 20 patients, aged 8 to 59 years, the labelled thrombocytes were used for scintiscanning of thrombus formation in the vascular system of transplanted kidneys. In patients with either acute or chronic rejection of the graft an enrichment of labelled thrombocytes was observed in the graft up to 12 hours before the increase of plasma creatinine, whereas patients with functioning grafts did not reveal any accumulation of labelled platelets. Thus scintigraphy with 111 In-oxine-labelled platelets proved to be a sensitive method, which first of all enables an early recognition of acute rejection reactions

  11. Reference values for the geometric centre analysis of colonic transit measurements with 111indium-labelled diethylenetriamine penta-acetic acid

    DEFF Research Database (Denmark)

    Madsen, Jan Lysgård; Fuglsang, Stefan; Graff, Jesper

    2003-01-01

    after oral administration of 111In-DTPA. Overall, the men had a higher geometric centre value than women after both 24 and 48 h indicating a faster progress of colonic contents in men at these time points. At each time point the geometric centre value was higher in both the young and middle......The geometric centre analysis is often used for evaluating colonic transit data obtained by scintigraphy after oral intake of 111indium-labelled diethylenetriamine penta-acetic acid (111In-DTPA). The purpose of this study was to establish reference values for the geometric centre analysis in adult......-aged subjects than in the elderly subjects, whereas we did not find any difference between young and middle-aged subjects. Furthermore, the smokers had a higher geometric centre value than non-smokers at each time point. The geometric centre value was not influenced by body mass index at any time point....

  12. Extraction, radiolabeling, and in vivo catabolism of autologous-origin equine fibrinogen and platelets in the healthy and exercise-stressed horse

    International Nuclear Information System (INIS)

    Coyne, C.P.

    1986-01-01

    Three separate techniques were evaluated for the extraction of autologous-origin fibrinogen from whole equine plasma. Rapid extraction of equine fibrinogen with ammonium sulfate-sodium phosphate buffer, in combination with saturated glycine buffer, provided the most practical means of obtaining a protein extract with the highest degree of biological activity and sufficiently high iodine-125 ( 125 I) radiolabeling efficiencies using monochloroiodine reagent (ICI). A technique was developed for the in vitro radiolabeling of equine platelets suspended in plasma. This entailed the use of the isotope, indium-111 ( 111 In), together with the lipophilic ligand, 2-(mercaptopyridine-N-oxide). This labeling technique achieved labeling efficiencies between 75% and 96%, and in vitro aggregability of 111 In-merc radiolabeled platelets was comparable to that of unlabeled cell isolates. In the final phase of the investigation, autologous-origin 125 I-labeled fibrinogen and 111 In-labeled platelets were applied in a series of equine exercise physiology studies. Elimination of these two radiobiologicals was evaluated in the resting and exercise-stressed horse. Results from these investigations revealed no long-term influence of exercise conditioning on the in vivo kinetics of radiolabeled fibrinogen or platelets

  13. Iodine-125 metaraminol: A new platelet specific labeling agent

    International Nuclear Information System (INIS)

    Ohmomo, Y.; Yokoyama, A.; Kawaii, K.; Horiuchi, K.; Saji, H.; Torizuka, K.

    1984-01-01

    In the search for a platelet specific labeling agent, Metaraminol (MA), which is a sympatomimetic amine used for the treatment of hypotension, cardiogenic shock and well recognized as a drug actively incorporated and accumulated in platelet, attracted the authors' attention. Using the classical chloramine-T iodination method, a high labeling efficiency near 98%, reaching a specific activity up to about 1000 Ci/mmole was obtained. Upon the harvest of platelet, only as platelet rich plasma (PRP), the labeling with this radiopharmaceutical was easily performed by incubation at 37 0 C for 10 min. Labeling efficiency as high as 63.0 +- 3.1% at 24 x 10/sup 8/ cells/ml was obtained. In in-vitro studies, the unaltered state of I-125 MA labeled platelet, with their cellular functions fully retained was demonstrated. Pharmacological study indicated a specific incorporation of I-125 MA by active transport system similar to that of 5-HT, along with passive diffusion. Then the in-vivo study carried out in rabbits with induced thrombi on the femoral artery, showed rather rapid disappearance of the I-125 MA labeled autologous platelet radioactivity, from circulating blood reaching as high thrombus-to-blood activity ratio as 19.8+-4.3 within 30 min post-administration. This new platelet labeling agent, I-125 MA, has many advantages over the use of IN-111 oxine and holds considerable promise for thrombus imaging with single photon emission CT upon the availability of I-123 MA

  14. The migration of 111Indium-labelled polymorphonuclear leucocytes into the oral cavity in the rhesus monkey

    International Nuclear Information System (INIS)

    Scully, C.; Challacombe, S.J.

    1979-01-01

    The route of migration of polymorphonuclear leucocytes (PMNL) from blood to the oral cavity was examined in rhesus monkeys. PMNL were isolated from the peripheral blood of eleven rhesus monkeys by dextran sedimentation, radiolabelled with 111 Indium and administered intravenously. Sequential samples of crevicular fluid washings (CFW), mixed and parotid saliva and mucosal washings were taken after injection of the labelled PMNL and harvested on glass fibre discs. Highest numbers of labelled PMNL were detected in CFW. CEll-associated radioactivity was detected in CFW within 20 min of injection of labelled PMNL and reached a maximal level 1 hour after injection. PMNL were found in CFW from monkeys with clinically normal gingiva but the number of labelled PMNL in CFW increased with increasing gingival index. Significant number of PMNL migrated into mixed saliva within 30 min, and low numbers of PMNL were detected in mucosal washings and in parotid saliva after 30 min. The results indicate that the migration time of the PMNL from blood to the oral cavity is less than 30 min, irrespective of the gingival index, that the gingival crevice is the main route of entry of PMNL to the oral cavity and that the numbers of PMNL migrating to the crevice increase as the gingival index rises. (author)

  15. Distribution of In-111 in granulocyte and other cellular elements of blood (CEB) in human In-111-labeled mixed white cell (MWC) and platelet preparations

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Chowdhury, S.; Brown, M.L.; Wahner, H.W.

    1984-01-01

    A large number of platelets (PLT), red blood cells (RBC) are present along with granulocyte (GC) in In-111 in CEB was determined by Ficoll-Hypaque gradient (FHG) centrifugation of In-111-MWC and PLT preparation as a quality control procedure. MWC were separated by sedimentation with hydroxyethyl starch; PLT by differential centrifugation. MWC and PLT were labeled with In-111-oxine in saline, ACD-saline or with In-111-tropolone in 0.5 ml of ACD-plasma. 0.3-0.5 ml of labeled cell suspended in plasma was layered on 3 ml FHG of two densities (1.119 and 1.077 gm/ml) and spun in a clear polystyrene tube at 1800 G for 30 min. Four layers (plasma, PLT, GC, and RBC) were separated, and In-111 radioactivity in each fraction was determined with a gamma counter. Simultaneously cell types in MWC and PLT preparations were determined by Coulter counter and differential counting. Most of In-111 in In-MWC is associated with the PLT and RBC, GC/lymphocyte ratio is 6/4. GC has higher extraction efficiency than RBC and PLT. PLT preparation is pure and (96 +- 3)% of In-111 is bound to PLT, (4 +- 3)% to RBC and (0.2 +- 0.1)% to GC; PLT preparation contains PLT (97 +- 3)%, RBC (4 +- 3)% and GC (0.2 +- 0.1)%

  16. Noninvasive radioisotopic technique for detection of platelet deposition in mitral valve prostheses and quantitation of visceral microembolism in dogs

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Fuster, V.; Rao, S.A.; Forshaw, P.L.; Kaye, M.P.

    1983-01-01

    A noninvasive technique has been developed in the dog model for imaging, with a gamma camera, the platelet deposition on Bjoerk-Shiley mitral valve prostheses early postoperatively. At 25 hours after implantation of the prosthesis and 24 hours after intravenous administration of 400 to 500 microCi of platelets labeled with indium-111, the platelet deposition in the sewing ring and perivalvular cardiac tissue can be clearly delineated in a scintiphotograph. An in vitro technique was also developed for quantitation of visceral microemboli in brain, lungs, kidneys, and other tissues. Biodistribution of the labeled platelets was quantitated, and the tissue/blood radioactivity ratio was determined in 22 dogs in four groups: unoperated normal dogs, sham-operated dogs, prosthesis-implanted dogs, and prosthesis-implanted dogs treated with dipyridamole before and aspirin and dipyridamole immediately after operation. Fifteen to 20% of total platelets were consumed as a consequence of the surgical procedure. On quantitation, we found that platelet deposition on the components of the prostheses was significantly reduced in prosthesis-implanted animals treated with dipyridamole and aspirin when compared with prosthesis-implanted, untreated dogs. All prosthesis-implanted animals considered together had a twofold to fourfold increase in tissue/blood radioactivity ratio in comparison with unoperated and sham-operated animals, an indication that the viscera work as filters and trap platelet microemboli that are presumably produced in the region of the mitral valve prostheses. In the dog model, indium-111-labeled platelets thus provide a sensitive marker for noninvasive imaging of platelet deposition on mechanical mitral valve prostheses, in vitro evaluation of platelet microembolism in viscera, in vitro quantitation of surgical consumption of platelets, and evaluation of platelet-inhibitor drugs

  17. The use of 111In-labelled platelets for scintigraphic localization of gastrointestinal bleeding with special reference to occult bleeding

    International Nuclear Information System (INIS)

    Gjerloeff Schmidt, K.; Waever Rasmussen, J.; Grove, O.; Andersen, D.

    1986-01-01

    Gamma-camera imaging of the abdomen after injection of autologous 111 In-labelled platelets was applied for localization of gastrointestinal bleeding in a study of 22 patients. In 15 studies showing scintigraphic signs of bleeding, the clinical presentation included occult bleeding in 6, melaena in 4, and bloody stools in 5 patients. Scintigraphy could be done repeatedly for up to 1 week after a single tracer injection. The time interval between the injection and scintigraphic visualization of bleeding ranged from 10 min to 68 h, being longest in cases of occult bleeding. In most cases the scintigraphic findings were supported by other diagnostic modalities, including surgical removal of presumed sources of bleeding. In seven studies without scintigraphic signs of bleeding, a probable source of bleeding was identified by other means in one patient. The 111 In-platelet method seems to be a promising method for localization of gastrointestinal bleeding which may prove particularly useful in cases of occult or recurrent bleeding

  18. 111Indium-labeled neutrophil migration into the lungs of bleomycin-treated rabbits assessed noninvasively by external scintigraphy

    International Nuclear Information System (INIS)

    Haslett, C.; Shen, A.S.; Feldsien, D.C.; Allen, D.; Henson, P.M.; Cherniack, R.M.

    1989-01-01

    Factors controlling neutrophil migration into the lung are poorly understood, but their identification is important for our understanding of the pathogenesis of inflammatory lung diseases. Pulmonary inflammation is difficult to quantify, and neutrophils in tissues and BAL may not accurately represent cell migration. In this study, intravenously delivered pulses of rabbit neutrophils labeled with Indium-111 (111In-neutrophils) were used to monitor neutrophil migration into the lungs. Radioactivity quantified in the lung region of interest (ROI) of external gamma camera scintigrams recorded 24 h after intravenous 111In-neutrophil injection accurately reflected the actual neutrophil-associated lung tissue radioactivity. ROI radioactivity at 24 h also correlated closely with the percent of 111In-neutrophils that had migrated into lavageable air spaces, and this parameter therefore provided an index of total lung 111In-neutrophil migration. Using 24-h ROI radioactivity and percent of injected 111In-neutrophils recovered in BAL at 24 h as indices of neutrophil migration into the lung, it was found that intratracheal saline caused only a transient neutrophil migration, whereas 10 U/kg intratracheal bleomycin induced migration that persisted for as long as 3 wk. 111In-neutrophil migration into the lung, assessed by external scintigraphy, correlated with total neutrophils quantified in histologic sections (r = 0.71, p = 0.006). The data suggest that this approach will be valuable in investigating mechanisms controlling neutrophil migration in lung inflammation, and that 111In-neutrophil scintigraphy may provide a noninvasive index of total lung neutrophil load that might be useful in staging inflammation in patchy diseases such as idiopathic pulmonary fibrosis

  19. Targeting of indium 111-labeled bivalent hapten to human melanoma mediated by bispecific monoclonal antibody conjugates: Imaging of tumors hosted in nude mice

    International Nuclear Information System (INIS)

    Le Doussal, J.M.; Gruaz-Guyon, A.; Martin, M.; Gautherot, E.; Delaage, M.; Barbet, J.

    1990-01-01

    Antibody conjugates were prepared by coupling F(ab')2 or Fab' fragments of an antibody specific for the human high molecular weight-melanoma associated antigen to Fab' fragments of an antibody specific for indium-diethylenetriaminepentaacetate complexes. Monovalent and bivalent haptens were synthesized by reacting the dipeptide tyrosyl-lysine with diethylenetriaminepentaacetic cyclic anhydride. In vitro, the antibody conjugate mediated binding of the 111In-labeled haptens to melanoma cells. In vivo, it allowed specific localization of the haptens in A375 tumors. The bivalent hapten exhibited much higher efficiency at targeting 111In onto cells, both in vitro and in vivo. Antibody conjugate and hapten doses (2 micrograms and 1 pmol, respectively) and the delay between antibody conjugate and tracer injections (24 h) were adjusted to maximize tumor uptake (4% injected dose/g) and tumor to normal tissue contrast (greater than 3) obtained 3 h after injection of the 111In-labeled bivalent hapten. This two-step technique, when compared to direct targeting of 111In-labeled F(ab')2 fragments, provided lower localization of injected activity into the tumor (x 0.25), but higher tumor/tissue ratios, especially with respect to liver (x 7), spleen (x 8), and kidneys (x 10). In addition, high contrast images were obtained within 3 hours, instead of days. Thus, antibody conjugate-mediated targeting of small bivalent haptens, labeled with short half-life isotopes, is proposed as a general method for improving tumor radioimmunolocalization

  20. Indium 111 leucocyte scintigraphy in abdominal sepsis

    International Nuclear Information System (INIS)

    Baba, A.A.; McKillop, J.H.; Gray, H.W.; Cuthbert, G.F.; Neilson, W.; Anderson, J.R.

    1990-01-01

    We have studied the clinical utility of indium 111 autologous leucocyte scintigraphy retrospectively in 45 patients presenting with suspected intra-abdominal sepsis. The sensitivity was 95% (21/22) and the specificity was 91% (21/23). Some 34 of the studies (17 positive and 17 negative) were considered helpful in furthering patient management (76%) and 8, unhelpful (18%). In 3, the study results were misleading and led to inappropriate treatment. Indium 111 scintigraphy, whether positive or negative, provides information in patients with suspected intra-abdominal sepsis upon which therapeutic decisions can be based. (orig.)

  1. Indium-granulocyte scanning in the painful prosthetic joint

    International Nuclear Information System (INIS)

    Pring, D.J.; Henderson, R.G.; Keshavarzian, A.; Rivett, A.G.; Krausz, T.; Coombs, R.R.; Lavender, J.P.

    1986-01-01

    The value of indium-111-labeled granulocyte scanning to determine the presence of infection was assessed in 50 prosthetic joints (41 of which were painful) in 40 patients. Granulocytes were obtained from the patients' blood and labeled in plasma with indium 111 tropolonate. Abnormal accumulation of indium 111 in the region of the prosthesis was noted. Proven infection occurred in 11 prostheses, and all of the infections were detected by indium-111-labeled granulocyte scanning. Nineteen were not infected (including nine asymptomatic controls) and only two produced false-positive scans. This represents a specificity of 89.5%, sensitivity of 100%, and overall accuracy of 93.2%. These results compare favorably with plain radiography. There was no radiologic evidence of infection in three of the infected prostheses, and 10 of the noninfected prostheses had some radiologic features that suggested sepsis. We conclude that indium-granulocyte scanning can reliably detect or exclude infection in painful prosthetic joints and should prove useful in clinical management

  2. Indium-111 autologous tagged leukocytes in the diagnosis of intraperitoneal sepsis

    International Nuclear Information System (INIS)

    Ascher, N.L.; Ahrenholz, D.H.; Simmons, R.L.; Weiblen, B.; Gomez, L.; Forstrom, L.A.; Frick, M.P.; Henke, C.; McCullough, J.

    1979-01-01

    The results of a new test using indium oxine in the diagnosis of postoperative infection are reported. Indium-111 was used to label autologous polymorphonuclear leukocytes, which when reinjected migrate to sites of infection and inflammation. Standard scintigraphy localizes the labeled inflammatory cells at these sites. Sixty-six scans were performed in 43 surgical patients. Thirty-seven scans were categorized as true-positive; 19 scans were categorized as true-negative. Therefore, the accuracy rate was 85%. Two scans (3%) in one patient represented false-positive results. Two scans (3%) were positive for inflammation but there was no infection present; this group was denoted as equivocal. Six scans (9%) were false-negative; false-negative scans are more likely in old lesions with poor blood supply and in areas that overlap regions of normal uptake. The noninvasive nature of the test, high accuracy rate, and ease of administration make it a potentially useful tool in the diagnosis of postoperative infection

  3. Scintigraphic assessment of focal platelet accumulations following infrainguinal bypass surgery in humans

    DEFF Research Database (Denmark)

    Nielsen, Tina G; Hesse, B; Eiberg, J

    1997-01-01

    . In 28 patients undergoing in situ vein (n = 24), composite vein-polytetrafluoroethylene (PTFE) (n = 1) or PTFE (n = 3) bypass surgery, assumed vascular injuries were recorded intraoperatively. Autologous indium-111-labelled platelets were injected into the inflow artery immediately after restoration...... antiplatelet therapy or vein graft diameter. Only 2 of the 20 intragraft platelet depositions occurred in areas where intra-operative vascular injury was suspected. In the composite graft and the PTFE grafts, diffuse activity was observed throughout the entire bypass. In conclusion, focal activity...

  4. Distribution and dosimetry of indium-111 labeled F(ab')2 fragments in humans

    International Nuclear Information System (INIS)

    Doherty, P.; Schwinger, R.; King, M.; Gionet, M.

    1986-01-01

    The purpose of this study was to obtain quantitative biodistribution data in patients injected with the indium-111 labeled F(ab') 2 fragments of mouse monoclonal antibody. From this data dosimetric calculations were made for the individual organs. The authors also evaluated the quantitative properties of SPECT in this application and compared it with the more conventional two view planar technique in both phantom and patient studies. For one antibody (19-9) the mean dose in rads/mCi for the organs of highest accumulation, namely, the liver and kidneys was 3.2 and 2.6 respectively. Preliminary data from another antibody (OC 125) showed much higher blood levels and a significantly lower liver dose of 2.3 indicating that antibody type is another significant determinant in dosimetry. The SPECT approach particularly in the presence of background activity, was more accurate in the phantom studies and resulted in larger estimated doses in the patient studies. Also, SPECT has the added advantage of providing an index of organ volume, which has to be balanced with the fact the planar is more rapid, and does not require special hardware. 24 references, 5 figures, 1 table

  5. Edwardsiella tarda Endocarditis Confirmed by Indium-111 White Blood Cell Scan: An Unusual Pathogen and Diagnostic Modality

    Directory of Open Access Journals (Sweden)

    Kayleigh M. Litton

    2016-01-01

    Full Text Available Edwardsiella tarda is a freshwater marine member of the family Enterobacteriaceae which often colonizes fish, lizards, snakes, and turtles but is an infrequent human pathogen. Indium-111- (111In- labeled white blood cell (WBC scintigraphy is an imaging modality which has a wide range of reported sensitivity and specificity (from 60 to 100% and from 68 to 92%, resp. for diagnosing acute and chronic infection. We describe a case of suspected E. tarda prosthetic aortic valve and mitral valve endocarditis with probable vegetations and new mitral regurgitation on transthoracic and transesophageal echocardiograms which was supported with the use of 111In-labeled WBC scintigraphy.

  6. Role of delayed indium-111 labeled leukocyte scan in the management of Crohn's disease

    International Nuclear Information System (INIS)

    Slaton, G.D.; Navab, F.; Boyd, C.M.; Diner, W.C.; Texter, E.C. Jr.

    1985-01-01

    Comparison of nine patients with Crohn's disease who had a positive delayed (24 hr) 111 indium leukocyte scan and 10 patients with negative scan showed no significant difference between the two groups for the Crohn's disease activity index, sedimentation rate, survival, complications, number of days in hospital, outpatient visits, or readmissions. Despite the apparent lack of statistical significance in Crohn's disease activity index, the scan was positive in nine of 16 patients with a Crohn's disease activity index more than 150, and none of three patients with Crohn's disease activity index less than 150. In the patients studied, there were no false-positive leukocyte scans. In nine of 10 patients with ileocolonic disease, scanning results correctly predicted the proper management. Six patients with positive scan and enteroclysis responded to medical treatment. Four patients had positive enteroclysis and negative scan; of these, three had radiographic features of chronic ileal stricture which was confirmed at operation. The results suggest that a negative delayed indium-111 leukocyte scan may be useful in diagnosis of chronic fibrotic ileal stricture

  7. Total-hip arthroplasty: Periprosthetic indium-111-labeled leukocyte activity and complementary technetium-99m-sulfur colloid imaging in suspected infection

    International Nuclear Information System (INIS)

    Palestro, C.J.; Kim, C.K.; Swyer, A.J.; Capozzi, J.D.; Solomon, R.W.; Goldsmith, S.J.

    1990-01-01

    Indium-111-labeled leukocyte images of 92 cemented total-hip arthroplasties were correlated with final diagnoses. Prostheses were divided into four zones: head (including acetabulum), trochanter, shaft, and tip. The presence (or absence) and intensity of activity in each zone was noted, and compared to the corresponding contralateral zone. Though present in all 23 infected arthroplasties, periprosthetic activity was also present in 77% of uninfected arthroplasties, and was greater than the contralateral zone 51% of the time. When analyzed by zone, head zone activity was the best criterion for infection (87% sensitivity, 94% specificity, 92% accuracy). Fifty of the arthroplasties were studied with combined labeled leukocyte/sulfur colloid imaging. Using incongruence of images as the criterion for infection, the sensitivity, specificity, and accuracy of the study were 100%, 97%, and 98%, respectively. While variable periprosthetic activity makes labeled leukocyte imaging alone unreliable for diagnosing hip arthroplasty infection, the addition of sulfur colloid imaging results in a highly accurate diagnostic procedure

  8. SU-E-I-14: Comparison of Iodine-Labeled and Indium-Labeled Antibody Biodistributions

    Energy Technology Data Exchange (ETDEWEB)

    Williams, L [Retired from City of Hope Medical Center, Arcadia, CA (United States)

    2014-06-01

    Purpose: It is often assumed that animal biodistributions of novel proteins are not dependent upon the radiolabel used in their determination. In units of percent injected dose per gram of tissue (%ID/g), organ uptake results (u) may be obtained using either iodine or metal as radioactive labels. Iodination is preferred as it is a one-step process whereas metal labeling requires two chemical procedures and therefore more protein material. It is important to test whether the radioactive tag leads to variation in the uptake value. Methods: Uptakes of 3antibodies to Carcinoembryonic Antigen (CEA) were evaluated in a nude mouse model bearing 150 to 300 mg LS174T human colon cancer xenografts. Antibodies included diabody (56 kDa), minibody (80kDa) and intact M5A (150 kDa) anti-CEA cognates. Both radioiodine and indium-111 labels were used with uptakes evaluated at 7 time(t) points out to 96 h. Ratios (R) of u(iodine-label)/u(indium-label) were determined for liver, spleen, kidneys, lung and tumor. Results: Hepatic loss was rapid for diabody and minibody; by 24 h their R values were only 2%; i.e., uptake of iodine was 2% of that of indium for these 2 antibodies. By contrast, R for the intact cognate was 50% at that time point. Splenic results were similar. Tumor uptake ratios did not depend upon the antibody type and were 50% at 24 h. Conclusions: Relatively rapid loss of iodine relative to indium in liver and spleen was observed in lower mass antibodies. Tumor ratios were larger and independent of antibody type. Aside from tumor, the R ratio of uptakes depended on the antibody type. R values decreased monotonically with time in all tissues and for all cognates. Using this ratio, one can possibly correct iodine-based u (t) results so that they resemble radiometal-derived biodistributions.

  9. Noninvasive radioisotopic technique for detection of platelet deposition in mitral valve prosthesis and renal microembolism in dogs

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Kaye, M.P.; Fuster, V.; Rao, S.A.

    1980-01-01

    At 24 hrs after implantation of Bjoerk-Shiley mitral prosthesis in 5 dogs, in vivo images were obtained with a gamma camera after intravenous administration (0.5-0.6 mCi) one hour postoperatively of autologous Indium-111-labeled platelets. The site of platelet deposition in the teflon ring and perivascular damaged cardiac tissue is clearly delineated in the scintiphoto. In vitro biodistribution (mean % +/- SD of injected dose) at 24 hrs after injection of the 5 implanted and 7 normal dogs performed with a gamma counter demonstrated that (45.1 +/- 10.6)% and (0.7 +/- 0.4)% were in blood and kidneys in normal dogs and (28.5 +/- 6.8)%, (1.6 +/- 0.6)%, (0.3 +/- 0.1)%, and (0.2 +/- 0.1)% were in blood, kidneys, teflon rings, and perivascular damaged cardiac tissue, respectively. The strut and pyrolytic carbon-coated disc retained only (0.0033 +/- 0.0004)% and (0.0031 +/- 0.0003)%, respectively. There was a 2.3-fold increase of labeled platelets in kidneys of implanted dogs due to renal trapping of microembolism. Also, three- to fivefold increase in ratios of lung, brain, cardiac, and skeletal muscle to blood indicates that internal organs and whole body work as filter for microembolism generated by cardiovascular surgery and mitral prosthesis. Twenty percent of the administered platelets are consumed in surgical repair of damaged tissue. Indium-111-labeled platelets thus provide a sensitive marker for noninvasive imaging of Bjoerk-Shiley mitral prosthesis, thromboembolism after implantation of prosthetic device, and in vitro quantitation of surgical consumption

  10. Labeling with indium-111 has detrimental effects on human lymphocytes: concise communication

    NARCIS (Netherlands)

    ten Berge, R. J.; Natarajan, A. T.; Hardeman, M. R.; van Royen, E. A.; Schellekens, P. T.

    1983-01-01

    When lymphocytes from human peripheral blood were labeled with In-111 oxinate, several of their properties appeared to be affected. The spontaneous release of the radionuclide was found to be relatively high. Labeled lymphocytes showed a decreased proliferative capacity, dependent on the dose of the

  11. Preclinical evaluation of intravenously administered 111In-and 90Y-labeled B72.3 immunoconjugate (GYK-DTPA) in beagle dogs

    International Nuclear Information System (INIS)

    Quadri, S.M.; Vriesendorp, H.M.; Yi Shao; Blum, J.E.; Leichner, P.K.; Williams, J.R.

    1993-01-01

    B72.3, a monoclonal antibody with reactivity against human adenocarcinomas was obtained from the Cytogen Corporation in the form of an immunoconjugate coupled with linker-chelator GYK-DTPA by using proprietary carbohydrate directed site specific chemistry. The immunoconjugate was radiolabeled with indium-111 or yttrium-90. A preclinical analysis was performed in 10 normal beagle dogs. The pharmacokinetics of intravenously administered indium- and yttrium-labeled immunoconjugates were compared serially in blood, bone marrow and urine samples. Compared to 90 Y less of the 111 In label ended up in urine and more was found in blood and bone marrow. Indium-labeled B72.3 GYK-DTPA had relatively higher uptake in most glandular tissues than 111 In-labeled antiferritin immunoconjugate. Bone marrow toxicity was the dose limiting side effect after intravenous infusion of 90 Y-labeled B72.3 GYK-DTPA. Toxicity was also observed in the liver but not in other organ systems. Recently other investigators obtained similar results with these immunoconjugates in human patients. A preclinical pharmacokinetic analysis of radioimmunoconjugates in beagle dogs provided useful information regarding bone marrow toxicity, liver toxicity and in vivo instability of the immunoconjugate. Data suggest that for future trials in human patients, a more stable chelated immunoconjugate for yttrium is needed to achieve less liver uptake and a better correlation with the 111 In-labeled product than the 90 Y-labeled B72.3 GYK-DTPA used in this investigation. (Author)

  12. Diagnosis of infection by preoperative scintigraphy with indium-labeled white blood cells

    International Nuclear Information System (INIS)

    Wukich, D.K.; Abreu, S.H.; Callaghan, J.J.; Van Nostrand, D.; Savory, C.G.; Eggli, D.F.; Garcia, J.E.; Berrey, B.H.

    1987-01-01

    Scintigraphy with indium-labeled white blood cells has been reported to be sensitive and specific in the diagnosis of low-grade sepsis of the musculoskeletal system. We reviewed the records of fifty patients who had suspected osteomyelitis or suspected infection about a total joint prosthesis and who underwent scintigraphy with technetium-99m methylene diphosphonate and scintigraphy with indium-111 oxine-labeled white blood cells before an open surgical procedure. Any patient who received preoperative antibiotics was not included in the study. For all of the patients, gram-stain examination of smears, evaluation of a culture of material from the operative site, and histological examination were done. The patients were divided into two groups. Group I was composed of twenty-four patients, each of whom had a prosthesis in place and complained of pain. Group II was composed of twenty-six patients for whom a diagnosis of chronic osteomyelitis had to be considered. With the indium scans alone, there was only one false-negative result (in Group II), but there were eighteen false-positive results (eight patients in Group II and ten patients in Group I). Although scintigraphy with indium-labeled white blood cells is quite sensitive, it is not specific in detecting chronic osteomyelitis; a negative scan should be considered highly suggestive that osteomyelitis is not present. Specificity can be increased by interpreting the indium scan in conjunction with the technetium scan

  13. Evaluation of indium-111-2-mercaptopyridine-N-oxide for labeling leukocytes in plasma: a kit preparation

    International Nuclear Information System (INIS)

    Thakur, M.L.; McKenney, S.L.; Park, C.H.

    1985-01-01

    Pure neutrophils, lymphocytes, and mixed leukocytes have been labeled in vitro with 111 In chelated to a nontoxic, water soluble agent 2-mercaptopyridine-N-oxide (Merc). Cells were labeled in isotonic salt-balanced medium with preformed [ 111 In]Merc, or in 0.5 ml autologous plasma by incubation with dry Merc first and then with 111 In. The latter method facilitated a kit procedure that required 2 μg dry Merc when acid citrate dextrose was used as anticoagulant or 20μg when heparin was used. Labeling efficiency was dependent on cell concentration and pH. Labeled cells accumulated avidly in experimental abscesses. In dogs, the liver uptake of labeled cells was only 18.8% compared to that of 48.5% when cells were labeled with [ 111 In] oxine

  14. Dual isotope study of iodine-125 and indium-111-labeled antibody in athymic mice

    Energy Technology Data Exchange (ETDEWEB)

    Carney, P.L.; Rogers, P.E.; Johnson, D.K. (Abbott Laboratories, Abbott Park, IL (USA))

    1989-03-01

    Monoclonal antibody B72.3 was coupled to a benzylisothiocyanate derivative of diethylenetriaminepentaacetic acid (DTPA). The maximum substitution achievable without loss of immunoreactivity was three DTPA groups per immunoglobulin molecule. The resulting conjugate was labeled with {sup 111}In by brief incubation with {sup 111}InCl{sub 3}, giving a mean radiochemical yield of {sup 111}In-labeled antibody of 96%. The ({sup 111}In)B72.3 preparation was mixed with an ({sup 125}I) B72.3 preparation, obtained by the chloramine-T method, and the mixture administered to athymic mice bearing subcutaneous LS174T colon carcinoma xenografts. There were no significant differences (p greater than 0.1) in the biodistributions of the two labels at 1, 2, 5, and 7 days postinjection. These results are contrasted with prior studies showing elevated levels of {sup 111}In in liver, spleen, and kidneys using B72.3-DTPA conjugates prepared via the bicyclic anhydride. It is concluded that protein cross-linking and/or the formation of unstable chelate sites in anhydride coupled conjugates underlie these disparities.

  15. Dual isotope study of iodine-125 and indium-111-labeled antibody in athymic mice

    International Nuclear Information System (INIS)

    Carney, P.L.; Rogers, P.E.; Johnson, D.K.

    1989-01-01

    Monoclonal antibody B72.3 was coupled to a benzylisothiocyanate derivative of diethylenetriaminepentaacetic acid (DTPA). The maximum substitution achievable without loss of immunoreactivity was three DTPA groups per immunoglobulin molecule. The resulting conjugate was labeled with 111 In by brief incubation with 111 InCl 3 , giving a mean radiochemical yield of 111 In-labeled antibody of 96%. The [ 111 In]B72.3 preparation was mixed with an [ 125 I] B72.3 preparation, obtained by the chloramine-T method, and the mixture administered to athymic mice bearing subcutaneous LS174T colon carcinoma xenografts. There were no significant differences (p greater than 0.1) in the biodistributions of the two labels at 1, 2, 5, and 7 days postinjection. These results are contrasted with prior studies showing elevated levels of 111 In in liver, spleen, and kidneys using B72.3-DTPA conjugates prepared via the bicyclic anhydride. It is concluded that protein cross-linking and/or the formation of unstable chelate sites in anhydride coupled conjugates underlie these disparities

  16. Thrombus imaging with [sup 99m]Tc-HMPAO-labeled platelets and [sup 111]In-labeled monoclonal antifibrin antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Vorne, M.S.; Honkanen, T.T.; Lantto, T.J.; Laitinen, R.O.; Karppinen, K.J.; Jauhola, S.V. (Depts. of Nuclear Medicine and Diagnostic Radiology, Paeijaet-Haeme Central Hospital, Lahti (Finland))

    1993-01-01

    Eighteen patients with suspicion of deep venous thrombosis (DVT) in the lower extremities were imaged both with autologous [sup 99m]Tc-HMPAO-labeled platelets (Tc-PLT) and [sup 111]In-labeled monoclonal antifibrin antibodies (In-MoAbs) on the same day. Precence or absence of thrombosis was verified by venography. Tc-PLT was given i.v. followed after 30 min by In-MoAbs. Anterior and posterior projections of the lower extremities were obtained with a large field-of-view gamma camera at 5 to 25 min, 2 h, 4 to 6 h, and 20 h after administration of the marker. Both Tc-PLT and In-MoAbs detected DVT well but less frequently than venography. Thrombi were visualized at 2 to 4 h after injection. The quality of images was better with Tc-PLT than with In-MoAbs. In the patients treated during the study, heparin significantly (p< 0.01) inhibited the uptake of Tc-PLT but not of In-MoAbs. We conclude that both Tc-PLT and In-MoAbs are suitable agents for the detection of DVT especially in patients without anticoagulation. (orig.).

  17. Study of biodistribution of lipidic nanospheres charged with cis-diaminedichloroplatinum (II) and labelled with radioactive nuclei of Indium-111; Estudio de biodistribucion de nanoesferas lipidicas cargadas con cis-diaminodicloroplatino (II) y marcadas con nucleos radioactivos de Indio-111

    Energy Technology Data Exchange (ETDEWEB)

    Lopez R, V.; Juarez O, C.; Medina L, A. [Unidad de Investigacion Biomedica en Cancer INCAN-UNAM, Mexico D.F. (Mexico); Perez C, E.; Garcia L, P. [Instituto nacional de cancerologia, Mexico D.F. (Mexico)

    2007-07-01

    The general objective of the study was to evaluate the lipidic nanospheres biodistribution charged with cis-diaminedichloroplatinum (II) (cis-DDP) and labelled with radioactive nuclei of Indium-111 (Lip-Cis-in-111) in Wistar rats and in a tumoral model of CaCu. The conclusions were: 1. The system Lip-Cis-in-111 it presents a very fast elimination probably, to a fast recognition response of the reticuloendothelial system (RES). 2. It is planned to make modifications to the formulation to increase the quantity of the hydrophilic polymer (PEG), so that its time of residence in the blood is bigger and allow a bigger accumulation in the tumor. (Author)

  18. In vivo imaging and quantitation of renal transplant rejection using indium-111 labelled anti-lymphocyte and anti-MHC class I and II monoclonal antibodies in a rat model

    International Nuclear Information System (INIS)

    Loutfi, I.; Batchelor, J.R.; Lavender, J.P.

    1992-01-01

    It has been described in this report, non-invasive and specific method for imaging and assessment of acute kidney transplant rejection in rat model. This model can serve as a basis for application in man using a cocktail of monoclonal antibodies with different specificities starting with monoclonal antibodies labelled with indium-111 which have been used in this technique. 3 refs., 1 tab., 2 figs

  19. The use of indium-111 platelet scintigraphy in man: comparisons with in vitro tests and in vivo platelet function--a five year experience

    International Nuclear Information System (INIS)

    Ezikowitz, M.D.; Ferri, P.; Pope, C.; Smith, E.O.; Snyder, E.L.

    1985-01-01

    In this paper, the authors present data collected from 540 patients between July 1978 and July 1983. They discuss briefly the method they employed for labeling platelets, emphasizing in vivo and in vitro markers of platelet function used for quality control of platelet preparation. They discuss the application of their technique for identification of mural left ventrical trombi, and review the disparity between in vivo and in vitro tests of platelet function. Then they deal with diagnosis of subacute bacterial endocarditis, deep veonus thrombosis, coronary trombi, left arterial masses, and the use of tomographic imaging. Finally they report changes in platelet function in stored platelets from normal volunteers

  20. Indium-111 labeled leukocyte images demonstrating a lung abscess with prominent fluid level

    International Nuclear Information System (INIS)

    Massie, J.D.; Winer-Muram, H.

    1986-01-01

    In-111 labeled leukocyte images show an abscess cavity with a fluid level on 24-hour upright images. Fluid levels, frequently seen on radiographs, are uncommon on nuclear images. This finding demonstrates rapid migration of labeled leukocytes into purulent abscess fluid

  1. Detection of deep venous thrombosis with indium 111-labelled monoclonal antibody against tissue plasminogen activator

    Energy Technology Data Exchange (ETDEWEB)

    Tromholt, N.; Hesse, B. (Hilleroed County Hospital (Denmark). Dept. of Clinical Physiology); Folkenborg, O. (Isotope-Pharmcy, Broenshoej (Denmark)); Selmer, J. (Novo Industri A/S, Bagsvaerd (Denmark)); Nielsen, N.T. (Hilleroed County Hospital (Denmark). Dept. of Radiology)

    1991-05-01

    The administration of a radiolabelled monoclonal antibody against tissue plasminogen activator allows detection of areas with increased fibrinolytic activity, i.e. those with an active thrombotic lesion. Eight patients with phlebographically verified deep venous thrombosis were examined. At the time of immunoscintigraphy study they were examined receiving anticoagulant therapy. Some 75-85 MBq {sup 111}In-labelled antibody were injected, and scintigrams were obtained after 30 min and after 24 h. The precise site of the thrombus could not be visualized after 30 min due to high background activity, whereas after 24 h it was detectable in all patients. The thrombus/background ratios achieved are twice as high as those observed in a human antifibrin antibody study. These preliminary data suggest a high sensitivity of our PA-specific antibody for the detection of active deep venous thrombosis in man, and our antibody seems to offer theoretical advantages over both platelet and fibrin-specific antibodies. (orig.).

  2. Detection of deep venous thrombosis with indium 111-labelled monoclonal antibody against tissue plasminogen activator

    International Nuclear Information System (INIS)

    Tromholt, N.; Hesse, B.; Selmer, J.; Nielsen, N.T.

    1991-01-01

    The administration of a radiolabelled monoclonal antibody against tissue plasminogen activator allows detection of areas with increased fibrinolytic activity, i.e. those with an active thrombotic lesion. Eight patients with phlebographically verified deep venous thrombosis were examined. At the time of immunoscintigraphy study they were examined receiving anticoagulant therapy. Some 75-85 MBq 111 In-labelled antibody were injected, and scintigrams were obtained after 30 min and after 24 h. The precise site of the thrombus could not be visualized after 30 min due to high background activity, whereas after 24 h it was detectable in all patients. The thrombus/background ratios achieved are twice as high as those observed in a human antifibrin antibody study. These preliminary data suggest a high sensitivity of our PA-specific antibody for the detection of active deep venous thrombosis in man, and our antibody seems to offer theoretical advantages over both platelet and fibrin-specific antibodies. (orig.)

  3. Labelling of bacteria with indium chelates

    International Nuclear Information System (INIS)

    Kleinert, P.; Pfister, W.; Endert, G.; Sproessig, M.

    1985-01-01

    The indium chelates were prepared by reaction of radioactive indiumchloride with 10 μg oxine, 15 μg tropolone and 3 mg acetylacetone, resp. The formed chelates have been incubated with 10 9 germs/ml for 5 minutes, with labelling outputs from 90 to 95%. Both gram-positive (Streptococcus, Staphylococcus) and gram-negative bacteria (Escherichia coli) can be labelled. The reproductive capacity of the bacteria was not impaired. The application of indium labelled bacteria allows to show the distribution of microorganisms within the living organism and to investigate problems of bacterial adherence. (author)

  4. In vitro comparison of renal handling and uptake of two somatostatin receptor-specific peptides labeled with indium-111

    International Nuclear Information System (INIS)

    Trejtnar, F.; Novy, Z.; Petrik, M.; Laznickova, A.; Melicharova, L.; Vankova, M.; Laznicek, M.

    2008-01-01

    Radiolabeled receptor-specific somatostatin analogs labeled with gamma- or beta-emitting radionuclides are useful for scintigraphic imaging and/or therapy of selected neuroendocrine tumors. However, significant renal uptake may result in radiotoxicological injury of the kidney and can limit clinical application of the agents. The aim of the study was to analyze renal handling, rate, and mechanism of renal accumulation of two somatostatin receptor-targeted peptides, [DOTA 0 , Tyr 3 , Thr 8 ]-octreotide (DOTA-TATE) and [DOTA 0 , 1-Nal 3 ]-octreotide (DOTA-NOC), labeled with indium-111 using in vitro methods. The perfused rat kidney and freshly isolated rat renal cells were used as experimental models. The perfusion was performed in a recirculation regimen at constant pressure with solution containing bovine albumin, erythrocytes, and a mixture of essential substrates. The renal cells were isolated from rat kidneys using two-phase collagenase perfusion. Accumulation studies were used to evaluate the renal uptake of the peptides and to compare their accumulation with that of passively or actively transported model drugs. The influence of selected inhibitors of receptor-mediated endocytosis and the inhibition of energy-dependent transport processes on the uptake were also investigated using isolated renal cells. The renal clearance of 111 In-DOTA-NOC in the perfused rat kidney was significantly lower than that of 111 In-DOTA-TATE. Reverse situation was found in the case of renal retention. Pretreatment of the perfused kidney with maleate markedly decreased the renal retention. 111 In-DOTA-NOC was accumulated in the isolated renal cells at a higher rate than 111 In-DOTA-TATE (ratio 3:1). The uptake of the radiopeptides in renal cells was higher than the uptake of not only the passively transported sucrose but also actively transported and accumulated methylglucose. The rank order of potency to inhibit the uptake by active endocytosis was approximately aprotinin

  5. 111In-labeled nonspecific immunoglobulin scanning in the detection of focal infection

    International Nuclear Information System (INIS)

    Rubin, R.H.; Fischman, A.J.; Callahan, R.J.; Khaw, B.A.; Keech, F.; Ahmad, M.; Wilkinson, R.; Strauss, H.W.

    1989-01-01

    We performed radionuclide scanning after the intravenous injection of human IgG labeled with indium-111 in 128 patients with suspected focal sites of inflammation. Localization of 111In-labeled IgG correlated with clinical findings in 51 infected patients (21 with abdominal or pelvic infections, 11 with intravascular infections, 7 with pulmonary infections, and 12 with skeletal infections). Infecting organisms included gram-positive bacteria, gram-negative bacteria, Pneumocystis carinii, Mycoplasma pneumoniae, and Candida albicans. No focal localization of 111In-labeled IgG was observed in 63 patients without infection. There were five false negative results, and nine results were unusable. Serial scans were carried out in eight patients: continued localization correctly predicted relapse in six, and the absence of localization indicated resolution in two. To determine whether 111In-labeled IgG localization was specific for inflammation, we studied 16 patients with cancer. Focal localization occurred in 13 of these patients (5 with melanomas, 5 with gynecologic cancers, and 1 each with lymphoma, prostate cancer, and malignant fibrous histiocytoma). No localization was seen in patients with renal or colon cancer or metastatic medullary carcinoma of the thyroid. We conclude that 111In-labeled IgG imaging is effective for the detection of focal infection and that serial scans may be useful in assessing therapeutic efficacy. This technique may also be helpful in the evaluation of certain cancers

  6. Use of indium-111-oxinate-labelled granulocytes and thrombocytes in kidney transplantation

    International Nuclear Information System (INIS)

    Royen, E.A. van; Schoot, J.B. van der; Hardeman, M.R.; Surachno, S.; Veen, J.H. ten; Vreeken, J.; Wilmink, J.M.

    1981-01-01

    The diagnostic use of 111 In-oxinate-labelled granulocytes and thrombocytes in kidney graft rejection was studied in 39 transplant patients. Normal values were established for the deposition of these cells in stable, functioning kidney grafts. Although some 111 In granulocyte accumulation occurred in the graft during rejection, the increase was too slight to render the method suitable for the early diagnosis of rejection. Significant increased 111 In thrombocyte deposition was found during rejection periods, although large differences were observed in the degree of accumulation. Severity or type of rejection may relate to these differences. Post-transplantation follow-up by 111 In thrombocyte scintigraphy did not result in a much earlier diagnosis of rejection than classic clinical signs. However, more frequent bedside activity determinations might do so. (author)

  7. A bedside technique for the diagnosis of acute rejection in renal transplants using 111-In platelets

    International Nuclear Information System (INIS)

    Chandler, S.T.; Buckels, J.A.C.; Drolc, Z.; Hawker, R.J.; Barnes, A.D.; McCollum, C.N.

    1982-01-01

    A total of 33 patients was studied with the aim of developing a bedside method for providing early diagnosis of acute rejection using 111-In labelled platelets. Platelet deposition was detected in all patients suffering acute rejection. A significant increase in kidney/aortic arch ratio, as measured by the portable bedside system, preceded the clinical diagnosis in 70% of patients. Using this system, it appeared possible not only to diagnose acute rejection at an earlier stage but also to predict irrecoverable transplant loss even in the presence of tubular necrosis. By labelling the platelets repeatedly for at least two weeks after transplantation, the period of highest risk for acute rejection and other complications. The gamma camera should still be employed in the event of markedly increased platelet deposition to differentiate between rejection and vascular complications

  8. The labelling of Nanocoll[reg] with [111In] for dual-isotope scanning

    International Nuclear Information System (INIS)

    Mitterhauser, Markus; Wadsak, Wolfgang; Key Mien, Leonhard-; Eidherr, Harald; Roka, Sebastian; Zettinig, Georg; Angelberger, Peter; Viernstein, Helmut; Kletter, Kurt; Dudczak, Robert

    2003-01-01

    Visualization and biopsy of sentinel lymph nodes play an important role in planning and controlling the therapy of breast cancer. Hitherto two methods--scintigraphy or gamma probe detection after injection of [ 99m Tc]-nanocolloids and visual detection after injection of patent blue dye--are used routinely. There are no conclusive publications elucidating such important parameters as injection site, injection method and colloidal parameters. The present work aims to label Nanocoll[reg] with [ 111 In] to provide an alternative method, a simultaneous one-compound dual-isotope application. Methods: [ 111 In]-Indiumchloride was buffered with acetate and transferred to the nanocolloid. The colloid labelling reaction was complete after 30 min and filtrated through 100 nm Nuclepore[reg] filters. Results: Incorporation yield of [ 111 In]-Indium into the nanocolloid was nearly quantitative, the step associated with the major loss of activity was the particle sizing with a mean yield of 55%. Conclusion: The presented method allows for the routine supply of [ 111 In]-nanocolloids. Size-filtered [ 111 In]-Nanocoll[reg] shows the same particle size range as [ 99m Tc]-Nanocoll[reg

  9. Localization of indium-111 in human malignant tumor xenografts and control by chelators

    International Nuclear Information System (INIS)

    Watanabe, Naoyuki; Oriuchi, Noboru; Endo, Keigo; Inoue, Tomio; Tanada, Shuji; Murata, Hajime; Kim, E. Edmund; Sasaki, Yasuhito

    1999-01-01

    The kinetics of soluble indium-111 ( 111 In) in human malignant tumor xenografts and cells was investigated in combination with chelators. Firstly, without chelator, the kinetics of 111 In-chloride was investigated in vitro and in vivo using four human malignant neuroblastoma SK-N-MC, pulmonary papillary adenocarcinoma NCI-H441, pulmonary squamous cell carcinoma PC 9, and colon adenocarcinoma LS 180 cells and xenografts. 111 In was incorporated into tumor cells in vitro to a maximum level during a 60-min incubation. A maximum level of radioactivity was demonstrated in vivo in four human malignant tumors xenografted into nude mice at 24 h postinjection of 111 In-chloride. Secondly, the effect of edetate calcium disodium (CaNa 2 EDTA) on radioactivity in 111 In-labeled tumors xenografts and cells was studied in vitro and in vivo. CaNa 2 EDTA significantly reduced 111 In-activity from the labeled tumor xenografts, whereas it had no affect on the radioactivity in the labeled cells. Thirdly, the effect of CaNa 2 EDTA on radioactivity in human malignant tumors xenografted into nude mice injected with 111 In-chloride was investigated. In one group of mice CaNa 2 EDTA administered intraperitoneally at 1, 22, 34, 46, 58, and 70 h after injection of 111 In-chloride (postadministration), the localization of 111 In at the tumors was significantly decreased at 72 h compared with the control in all four tumor types. In the other group of mice, CaNa 2 EDTA administered intraperitoneally at 12 and 1 h before injection of 111 In-chloride and 1, 22, 34, 46, 58, and 70 h postinjection (pre- and postadministration), the radioactivity of tumors was also significantly decreased at 72 h, and the reduction was greater than that with use of postadministration. In a comparative study, CaNa 3 DTPA had a more powerful effect than CaNa 2 EDTA. In conclusion, 111 In-activity in tumors consists of intracellular and extracellular components, and the extracellular 111 In may be cleared by

  10. New 'ex vivo' radioisotopic method of quantitation of platelet deposition

    International Nuclear Information System (INIS)

    Badimon, L.; Mayo Clinic, Rochester, MN; Thrombosis and Atherosclerosis Unit, Barcelona; Mayo Clinic, Rochester, MN; Fuster, V.; Chesebro, J.H.; Dewanjee, M.K.

    1983-01-01

    We have developed a sensitive and quantitative method of 'ex vivo' evaluation of platelet deposition on collagen strips, from rabbit Achilles tendon, superfused by flowing blood and applied it to four animal species, cat, rabbit, dog and pig. Autologous platelets were labeled with indium-111-tropolone, injected to the animal 24 hr before the superfusion and the number of deposited platelets was quantitated from the tendon gamma-radiation and the blood platelet count. We detected some platelet consumption with superfusion time when blood was reinfused entering the contralateral jugular vein after collagen contact but not if blood was discarded after the contact. Therefore, in order to have a more physiological animal model we decided to discard blood after superfusion of the tendon. In all species except for the cat there was a linear relationship between increase of platelet on the tendon and time of exposure to blood superfusion. The highest number of platelets deposited on the collagen was found in cats, the lowest in dogs. Ultrastructural analysis showed the platelets were deposited as aggregates after only 5 min of superfusion. (orig.)

  11. False positive indium-111 white blood cell scan in a closed clavicle fracture

    International Nuclear Information System (INIS)

    Friedman, R.J.; Gordon, L.

    1988-01-01

    Aggressive treatment of the multiply injured patient often requires early fixation of many fractures, some of which may be open. Often, patients develop postoperative fevers requiring a thorough workup to rule out infection. Recently, indium-111 white blood cell (WBC) imaging has become a valuable adjunct in the diagnosis of acute infection. The patient described had a simple, closed clavicle fracture with markedly increased activity on an indium-111 WBC scan obtained for fever workup. This subsequently proved to be a normal, healing, noninfected fracture by other diagnostic techniques. Noninfected, simple closed fractures should be added to the list of causes for a false-positive indium-111 WBC scan

  12. Diagnosis of intra abdominal inflammatory processes with 111In-labelled leucocytes

    International Nuclear Information System (INIS)

    Roevekamp, M.H.; Brummelkamp, W.H.; Schoot, J.B. van der; Reinders Folmer, S.Chr.C.; Royen, E.A. van

    1982-01-01

    Over a two and a half year period, 225 scintigrams with indium-111 oxinate labelled leukocytes were performed in 184 patients suspected of an intra-abdominal, retroperitoneal or pelvic inflammatory process. In patients suspected of an upper abdominal process, an indium-111 leukocyte-99Tc-Sn colloid subtraction was performed, in order to eliminate the normal liver and spleen uptake. 123 Scintigrams were considered true positive and 73 true negative. A diagnostic accuracy of 87% was calculated. With 18 false-positive scans an 80%-specificity and with 11 false-negative a 92%-sensitivity were obtained. False-positive results in the majority of the scintigrams were based on leukocyte accumulations, due to aspecific cellular inflammatory reactions. False-negative results were mainly related to intra-hepatic, intra-splenic or older lesions. In 150 patients, ultrasonography and/or computed tomography was also performed. A higher diagnostic accuracy was observed with leukocyte scintigraphy compared to ultrasonography. (Auth.)

  13. Platelet deposition in rat heart allografts and the effect of a thromboxane receptor antagonist

    International Nuclear Information System (INIS)

    Foegh, M.L.; Khirabadi, B.S.; Ramwell, P.W.

    1986-01-01

    The effect of a thromboxane antagonist, L640,035 on platelet deposition in heart allografts was studied. Twenty Lewis rats received heterotopic allografts from Lewis x Brown-Norway F1 hybrid. All recipients received azathioprine (5 mg/kg/day). The rats were divided into three groups. Groups II and III were also treated daily with either the vehicle for L640,035 or L640,035 respectively. Syngeneic indium-111-labeled platelet deposition was determined in the allograft and the native heart at 6, 9, and 13 days after transplantation; group III was studied on the sixth and ninth day only. A rapidly increasing platelet deposition was seen in allografts from rats given azathioprine; whereas the thromboxane antagonist prevented the increase in platelet deposition on the ninth day

  14. Evaluation of musculoskeletal sepsis with indium-111 white blood cell imaging

    International Nuclear Information System (INIS)

    Ouzounian, T.J.; Thompson, L.; Grogan, T.J.; Webber, M.M.; Amstutz, H.C.

    1987-01-01

    The detection of musculoskeletal sepsis, especially following joint replacement, continues to be a challenging problem. Often, even with invasive diagnostic evaluation, the diagnosis of infection remains uncertain. This is a report on the first 55 Indium-111 white blood cell (WBC) images performed in 39 patients for the evaluation of musculoskeletal sepsis. There were 40 negative and 15 positive Indium-111 WBC images. These were correlated with operative culture and tissue pathology, aspiration culture, and clinical findings. Thirty-eight images were performed for the evaluation of possible total joint sepsis (8 positive and 30 negative images); 17 for the evaluation of nonarthroplasty-related musculoskeletal sepsis (7 positive and 10 negative images). Overall, there were 13 true-positive, 39 true-negative, two false-positive, and one false-negative images. Indium-111 WBC imaging is a sensitive and specific means of evaluating musculoskeletal sepsis, especially following total joint replacement

  15. Diffuse pulmonary uptake of indium-111 chloride in idiopathic myelofibrosis

    International Nuclear Information System (INIS)

    Vieras, F.; Boyd, C.M.; Mora, P.A.

    1979-01-01

    Unusual indium-111 accumulation and extramedullary hematopoiesis in the lungs of a patient with idiopathic myelofibrosis are described. The bone marrow scan taken 24 h after intravenous injection of 111 InCl 3 faithfully depicted the abnormal distribution of marrow elements as assessed histologically at autopsy, thereby supporting the usefulness of 111 InCl 3 for marrow imaging

  16. In vitro model of platelet aggregation in stenotic arteries

    International Nuclear Information System (INIS)

    Morley, D.; Santamore, W.P.

    1988-01-01

    Clinical and experimental evidence suggest a strong relationship between arterial stenosis, platelet aggregation, and subsequent thrombus formation. To facilitate the study of platelet accumulation in stenotic arteries, we developed an in vitro preparation. Arterial segments were perfused with whole citrated blood. A stenosis was created by applying an external plastic constrictor to the artery. Platelet accumulation within the stenosis was assessed by scanning electron microscopy and by radioactive counts from Indium-111 labeled platelets. Utilizing this preparation, 30 carotid arterial segments from 10 mongrel dogs were perfused at 100 mmHg for 15 min. In 10 arteries without a stenosis, scanning electron microscopy and radioactive counts demonstrated little platelet accumulation. In contrast, extensive platelet aggregation was observed in 10 arteries with stenoses. Moreover, in 10 stenotic arteries exposed to the thromboxane mimetic, U46619 (Upjohn Diagnostic Group), scanning electron microscopy and radioactive counts demonstrated a significant increase in platelet deposition. Conversely, we demonstrated a dimunition of platelet accumulation in stenosed arterial segments exposed to the prostacyclin analogue platelet inhibitor, Iloprost. The in vitro preparation allows precise control of hemodynamic variables and makes it possible to perform multiple tests on segments of the same vessel from the same animal

  17. Acute myocardial infarct imaging with indium-111-labeled monoclonal antimyosin Fab

    International Nuclear Information System (INIS)

    Khaw, B.A.; Yasuda, T.; Gold, H.K.; Leinbach, R.C.; Johns, J.A.; Kanke, M.; Barlai-Kovach, M.; Strauss, H.W.; Haber, E.

    1987-01-01

    Indium-111 monoclonal antimyosin Fab scintigraphy was used to detect myocardial necrosis in 52 of 54 patients (96.3%) with acute myocardial infarction. Infarcts were visualized when coronary arteries were persistently occluded (n = 10), became patent after thrombolysis (n = 33), or became patent after spontaneous reperfusion (n = 7). Posteroinferolateral visualizations were obtained in two patients with clinical and enzymatic evidence of infarction but normal electrocardiograms. Of the two patients in whom no infarcts were visualized, one had an anterior myocardial infarct. This patient underwent successful thrombolytic therapy, with attendant minimization of creatine kinase release. The other patient had a small, nonreperfused inferior myocardial infarct. Five patients with a history of remote infarction and acute necrosis showed antimyosin uptake only in regions concordant with the acute episodes of infarction, and radiolabeled antimyosin Fab localized in neither old infarcts nor normal, noninfarcted myocardium. Antimyosin Fab scintigraphy, thus, appears to be a highly specific means of delineating necrotic myocardium, at least in this limited and selected group of patients

  18. Colorectal carcinoma metastases: Detection with In-111-labeled monoclonal antibody CCR 086

    International Nuclear Information System (INIS)

    Abdel-Nabi, H.H.; Levine, G.; Lamki, L.M.; Murray, J.L.; Tauxe, W.N.; Shah, A.N.; Patt, Y.Z.; Doerr, R.J.; Klein, H.A.; Gona, J.

    1990-01-01

    A phase I/II clinical trial with indium-111-labeled antimucin murine monoclonal antibody (MoAb) CCR 086 was conducted. Seventeen patients with histologically proved colorectal carcinoma and known metastatic disease underwent external scintigraphy after administration of 5.5 mCi (203.5 MBq) of In-111 CCR 086 at doses of 5 and 20 mg. Of 25 known lesions, 17 were detected (sensitivity, 68%). The smallest detected lesion in the lung was 1 cm and in the liver was 1.5 cm. The serum half-life of In-111-labeled CCR 086 MoAb was approximately 64 hours. The formation of human antimouse antibody (HAMA) was detected in the serum of four of five patients who received 20 mg of MoAb. No HAMAs were detected in four patients receiving 5 mg of MoAb. No side effects were encountered. Because of effective detection of liver and lung metastases with lower doses (5-20 mg) of CCR 086 conjugated with In-111, further investigations are warranted to assess clinical and therapeutic potentials of CCR 086 in the management of colorectal cancer

  19. High sensitivity of the in vivo detection of somatostatin receptors by 111Indium (DTPA-Octreotide)-scintigraphy in meningioma patients

    International Nuclear Information System (INIS)

    Hildebrandt, G.; Luyken, C.; Klug, N.; Scheidhauer, K.; Schicha, H.; Dahms, P.; Krisch, B.

    1994-01-01

    The recent availability of isotope-labelled somatostatin analogues has allowed one to detect somatostatin receptors in normal tissue as well as in endocrine or non-endocrine cranial tumours. The purpose of the present study was to establish the value of somatostatin receptor scintigraphy using an 111 indium-labelled somatostatin analogue, octreotide, in the diagnostic work-up of meningioma patients. Twenty-two patients (16 women, 6 men, aged from 19-70 years) with newly diagnosed, residual or recurrent cranial meningiomas were examined. 111 indium-labelled DTPA-octreotide was injected i.v.. Planar and tomographic images were obtained with a gamma camera 4-6, and 24 hours after injection. In all of the meningiomas studies a high density of somatostatin receptor was detected by scintigraphy. No false negative test result was found. Due to this, a 100% predictive value of a negative test was calculated. However, when the tumours were taken in culture differing staining intensity could be seen in the light- and electron microscopic level even on individual cells of a single culture when silver intensified somatostatin-gold was used as ligand. We conclude, that in vivo somatostatin receptor scintigraphy may aid in the pre-operative differential diagnosis of skull base tumours

  20. New 'ex vivo' radioisotopic method of quantitation of platelet deposition

    Energy Technology Data Exchange (ETDEWEB)

    Badimon, L.; Fuster, V.; Chesebro, J.H.; Dewanjee, M.K.

    1983-01-01

    We have developed a sensitive and quantitative method of 'ex vivo' evaluation of platelet deposition on collagen strips, from rabbit Achilles tendon, superfused by flowing blood and applied it to four animal species, cat, rabbit, dog and pig. Autologous platelets were labeled with indium-111-tropolone, injected to the animal 24 hr before the superfusion and the number of deposited platelets was quantitated from the tendon gamma-radiation and the blood platelet count. We detected some platelet consumption with superfusion time when blood was reinfused entering the contralateral jugular vein after collagen contact but not if blood was discarded after the contact. Therefore, in order to have a more physiological animal model we decided to discard blood after superfusion of the tendon. In all species except for the cat there was a linear relationship between increase of platelet on the tendon and time of exposure to blood superfusion. The highest number of platelets deposited on the collagen was found in cats, the lowest in dogs. Ultrastructural analysis showed the platelets were deposited as aggregates after only 5 min of superfusion.

  1. In-111 labeled leukocyte scintigraphy in a case of multifocal candidiasis

    Energy Technology Data Exchange (ETDEWEB)

    Palestro, C.J.; Vega, A.; Kim, C.K.; Goldsmith, S.J. (Mount Sinai School of Medicine, New York, NY (USA))

    1990-06-01

    The value of indium-111 labeled leukocyte scintigraphy for the diagnosis of infection in the general population is well documented; there is less information available on its role in the evaluation of the immunocompromised patient. In this study, leukocyte scintigraphy was performed on a 31-year-old immunocompromised woman who had a possible intra-abdominal abscess. No abscess was detected, but intense oral, esophageal, gastric, and vaginal uptake was observed. Candida infection was histologically confirmed at all four sites.

  2. In-111 labeled leukocyte scintigraphy in a case of multifocal candidiasis

    International Nuclear Information System (INIS)

    Palestro, C.J.; Vega, A.; Kim, C.K.; Goldsmith, S.J.

    1990-01-01

    The value of indium-111 labeled leukocyte scintigraphy for the diagnosis of infection in the general population is well documented; there is less information available on its role in the evaluation of the immunocompromised patient. In this study, leukocyte scintigraphy was performed on a 31-year-old immunocompromised woman who had a possible intra-abdominal abscess. No abscess was detected, but intense oral, esophageal, gastric, and vaginal uptake was observed. Candida infection was histologically confirmed at all four sites

  3. Recruitment of 99m-technetium- or 111-indium-labelled polymorphonuclear leucocytes in experimentally induced pyogranulomas in lambs

    Energy Technology Data Exchange (ETDEWEB)

    Guilloteau, L.; Pepin, M.; Pardon, P.; Le Pape, A. (Institut National de la Recherche Agronomique, Nouzilly (France))

    1990-10-01

    The recruitment of polymorphonuclear leucocytes (PMNs) during the development of experimental pyogranulomas induced by Corynebacterium pseudotuberculosis was followed in nine male lambs by scintigraphic examination. Autologous blood PMNs were labelled with 99m-technetium or 111-indium and were re-injected intravenously into infected lambs. The functional properties of the labelled cells were monitored (1) in vitro by measuring their phagocytic and bactericidal activity against C. pseudotuberculosis and their chemotaxis under agarose, and (2) in vivo by following scintigraphically their capacity to accumulate in an inflammatory focus induced by intradermal injection of latex beads coated with Salmonella abortus equi lipopolysaccharide. Following inoculation of corynebacteria into the right ear of lambs, radioactive foci were observed to be localized in the right ear and in the draining lymph nodes during the 4 days following inoculation. Histopathological examination performed 32 h after inoculation confirmed the intense accumulation of PMNs at these sites. With the exception of one animal, which presented visible foci in the neck 14 days postinoculation, no radioactive foci were observed during the later phases of experimental infection, despite the presence of multiple pyogranulomas which were confirmed by bacteriological examination after necropsy of the lambs. Histopathological examination of these lesions revealed layers of fibroblasts, lymphocytes, and macrophages surrounding a necrotic centre. The results of these studies suggest that the contribution of PMNs during the chronic phase of inflammation is considerably reduced in comparison with the acute inflammatory phase of the infectious process.

  4. Recruitment of 99m-technetium- or 111-indium-labelled polymorphonuclear leucocytes in experimentally induced pyogranulomas in lambs

    International Nuclear Information System (INIS)

    Guilloteau, L.; Pepin, M.; Pardon, P.; Le Pape, A.

    1990-01-01

    The recruitment of polymorphonuclear leucocytes (PMNs) during the development of experimental pyogranulomas induced by Corynebacterium pseudotuberculosis was followed in nine male lambs by scintigraphic examination. Autologous blood PMNs were labelled with 99m-technetium or 111-indium and were re-injected intravenously into infected lambs. The functional properties of the labelled cells were monitored (1) in vitro by measuring their phagocytic and bactericidal activity against C. pseudotuberculosis and their chemotaxis under agarose, and (2) in vivo by following scintigraphically their capacity to accumulate in an inflammatory focus induced by intradermal injection of latex beads coated with Salmonella abortus equi lipopolysaccharide. Following inoculation of corynebacteria into the right ear of lambs, radioactive foci were observed to be localized in the right ear and in the draining lymph nodes during the 4 days following inoculation. Histopathological examination performed 32 h after inoculation confirmed the intense accumulation of PMNs at these sites. With the exception of one animal, which presented visible foci in the neck 14 days postinoculation, no radioactive foci were observed during the later phases of experimental infection, despite the presence of multiple pyogranulomas which were confirmed by bacteriological examination after necropsy of the lambs. Histopathological examination of these lesions revealed layers of fibroblasts, lymphocytes, and macrophages surrounding a necrotic centre. The results of these studies suggest that the contribution of PMNs during the chronic phase of inflammation is considerably reduced in comparison with the acute inflammatory phase of the infectious process

  5. Study on platelet kinetics

    International Nuclear Information System (INIS)

    Yui, Tokuo

    1981-01-01

    Fundamental study: Factors influencing the labeling on human platelets were evaluated and optimal labeling conditions were chosen. Then, platelet survival times were measured and organ distribution of labeled platelets was observed in rat by four different methods. These results were compared with each other. Based on the findings of those studies, the protocol of human platelet labeling with 111 In-oxine for clinical use was established. Clinical study: In normal cases, a platelet survival time and a platelet turnover rate were quite similar to the results from 51 Cr method. In gamma camera imaging, a radioactivity on the heart decreased with the lapse of time, while that on the spleen and liver gradually increased. In patients with idiopathic thrombocytopenic purpura, platelet survival time was markedly shortened and both a platelet turnover rate and an effective production increased. In patient with congestive splenomegaly, a platelet survival time was normal, whereas a platelet pooling on the spleen markedly increased. In patients who were implanted dacron-graft for abdominal aortic aneurysm, a radioactivity accumulated to the graft and a platelet survival time shortened. In a patient with myocardial infarction, the camera imaging clearly showed the thrombus in the left ventricular aneurysm. In three patients with mitral stenosis, thrombi in left atrium were observed at the camera images. Imaging of a platelet distribution and measurement of platelet survival time using 111 In-oxine labeled platelets are considered to be an excellent method for the diagnosis and decision of treatment on various disorders with thrombocytopenia and thrombosis. (J.P.N.)

  6. Indium-111 platelet imaging for detection of platelet deposition in abdominal aneurysms and prosthetic arterial grafts

    International Nuclear Information System (INIS)

    Ritchie, J.L.; Stratton, J.R.; Thiele, B.; Haminton, G.W.; Warrick, L.N.; Huang, T.W.; Harker, L.A.

    1981-01-01

    Thirty-four platelet imaging studies were performed in 23 patients to determine whether platelet deposition could be detected in patients with vascular aneurysms (18 patients) or in patients in whom Dacron prosthetic grafts had been placed (5 patients). In patients in whom abnormal platelet deposition was detected, the effect of administration of platelet-active drugs on platelet deposition was examined. Of the 18 patients with an aneurysm, 12 had equivocally positive studies on initial imaging and 2 had equivocally positive images. Of five patients with Dacron arterial grafts in place, four had diffuse platelet deposition in the grafts; the fifth patient had a platelet deposition only in a pseudoaneurysm. Eight patients with an abdominal aneurysm and positive or equivocally positive baseline images were restudied during platelet-active drug therapy either with aspirin plus dipyridamole (seven patients) or with sulfinpyrazone (four patients). No patient studied during treatment with aspirin plus dipyridamole had detectably decreased platelet deposition compared with baseline determinations. In contrast, two of four patients studied while receiving sulfinpyrazone showed decreased platelet deposition. Thus, platelet imaging may be of value for studying platelet physiology in vivo and for assessing platelet-active drugs and the thrombogenicity of prosthetic graft materials in human beings

  7. Scintigraphic detection of coronary artery thrombi in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Fox, K.A.; Bergmann, S.R.; Mathias, C.J.; Powers, W.J.; Siegel, B.A.; Welch, M.J.; Sobel, B.E.

    1984-01-01

    To determine whether coronary thrombi can be detected scintigraphically after acute myocardial infarction, 24 patients were studied with a new method employing indium-111-labeled platelets and technetium-99m-labeled red blood cells. Nine patients with suspected infarction were evaluated initially within 9 hours of the onset of symptoms and again 18 to 24 hours after onset. Foci of net indium accumulation were detected after image processing that incorporated subtraction of blood pool activity. Carotid and pulmonary artery reference regions, in which blood pool activity is high and active platelet deposition unlikely, were used to correct digitized cardiac scintigrams for indium-111 platelet activity in the blood pool. In patients with infarction, distinct foci of net indium accumulation were present in regions corresponding to the coronary artery supplying ischemic zones. This occurred in seven of eight patients at the time of the earliest evaluation after the onset of symptoms) and in eight of nine patients at the time of subsequent imaging (23.6 +/- 1.9 hours after onset). Only 1 of 15 control patients exhibited a cardiac focus of net indium accumulation. The percent of indium excess (100 [total indium-111 activity-blood pool indium-111 activity]/blood pool indium-111 activity) within the cardiac region measured (+/- SD) 16.8 +/- 11.6% in all patients with myocardial infarction (19.1 +/- 11.2% in those with visually identified foci) compared with 0.4 +/- 4.3% in control patients. This method permits early detection and sequential assessment of coronary artery thrombi

  8. 111 In-labeled leukocytes in the detection of prosthetic vascular graft infections

    International Nuclear Information System (INIS)

    Williamson, M.R.; Boyd, C.M.; Read, R.C.; Thompson, B.W.; Barnes, R.W.; Shah, H.R.; Balachandran, S.; Ferris, E.J.

    1986-01-01

    Making a clinical diagnosis of infection in prosthetic vascular grafts is difficult but when undiagnosed, this condition has a high mortality rate. Using Indium-111-labeled white-blood cells, 30 scans were performed in 21 patients suspected of having a prosthetic graft infection. The diagnosis of infected graft was confirmed by surgery in all cases, and lack of infection was established by resolution of symptoms with conservative therapy. Twenty-four hour scans of autologous Indium-111 leukocytes were obtained, and correlative CT studies were done in 11 cases. There were 13 infected grafts at surgery (purulent material present), and scans were positive in all (100% sensitivity); of 17 scans, there were 15 true negatives and two false positives (88% specificity). Using the criteria of gas or fluid around the graft, the sensitivity of CT was only 37% in a small subset of these patients. One-half of the cases in which infection was suspected clinically had no infection and had negative scans. Various types of grafts and graft materials were used, and there was no correlation with presence or absence of infection on the basis of the type of graft. Extragraft infection sites were found in five patients. In conclusion, use of Indium-111 leukocytes has been found to be an accurate and valuable diagnostic method for evaluation of suspected prosthetic vascular graft infection, and to have higher diagnostic accuracy than CT

  9. Indium 111 ZCE-025 immunoscintigraphy in occult recurrent colorectal cancer with elevated carcinoembryonic antigen level

    International Nuclear Information System (INIS)

    Doerr, R.J.; Abdel-Nabi, H.; Merchant, B.

    1990-01-01

    We investigated the utility of scanning with indium 111 labeled to monoclonal antibody in 13 patients after curative resection of colorectal cancer who had elevated carcinoembryonic antigen levels and negative results of clinical workup. Each patient received 1 mg of anti-carcinoembryonic antigen monoclonal antibody type ZCE 025 labeled with 5.5 mCi of 111 In, plus 9 to 39 mg of the same antibody unlabeled. Patients underwent scanning 3 to 7 days after infusion by planar and emission computed tomography. ZCE-025 monoclonal antibody imaging detected tumor recurrence or metastasis in 11 of 13 patients. In one patient the monoclonal antibody scan gave a true-negative result, and in one patient the monoclonal antibody scan failed to disclose a metachronous cecal primary. Tumor sites identified were the pelvis (2 patients), abdominal wall (2), retroperitoneum (1), lymph nodes (3); liver (2), bone (2), and lung (1). The accurate localization of colorectal carcinoma recurrences by means of 111 In ZCE-025 monoclonal antibody demonstrates the usefulness of this diagnostic agent in the setting of elevated carcinoembryonic antigen level and negative results of clinical and radiologic workup

  10. Loss of 51chromium, lactate dehydrogenase, and 111indium as indicators of endothelial cell injury

    International Nuclear Information System (INIS)

    Chopra, J.; Joist, J.H.; Webster, R.O.

    1987-01-01

    Injury to endothelial cells appears to be an important initial event in the pathogenesis of many diseases such as acute lung injury, venous and arterial thromboembolism, and atherosclerosis. Different methods for detecting damage to cultured endothelial cells have been described. However, their relative sensitivity as markers of endothelial cell damage has not been adequately determined. We compared the loss of 51 Chromium ( 51 Cr), the cytoplasmic enzyme lactate dehydrogenase (LDH), and 111 Indium ( 111 In) from endothelial cells upon exposure to several injurious agents. Cultured bovine pulmonary artery endothelial cells in confluent monolayers were labeled with 51 Cr or 111 Inoxine and exposed to increasing concentrations of the nonionic detergent, Triton X-100 (0.2 to 1%), hydrogen peroxide (1 to 500 microM), or neutrophils stimulated with phorbol myristate acetate. With all forms of injury, loss of 51 Cr occurred earlier and to a greater extent than LDH loss which in turn was greater than loss of 111 In. Substantial loss of 51 Cr was observed in the absence of appreciable ultrastructural damage to endothelial cell external membranes. The findings may reflect the relative ease with which small molecules such as adenine nucleotides ( 51 Cr-labeled) escape whereas larger molecules such as LDH and proteins binding 111 In are retained intracellularly. Thus, 51 Cr loss appears to be a more sensitive indicator of sublytic endothelial cell injury than either 111 In or LDH release

  11. Detection of rejection of canine orthotopic cardiac allografts with indium-111 lymphocytes and gamma scintigraphy

    International Nuclear Information System (INIS)

    Eisen, H.J.; Rosenbloom, M.; Laschinger, J.C.; Saffitz, J.E.; Cox, J.L.; Sobel, B.E.; Bolman, R.M. III; Bergmann, S.R.

    1988-01-01

    Previous studies have demonstrated the feasibility of detecting canine heterotopic cardiac allograft rejection scintigraphically after administration of 111In lymphocytes. To determine whether the approach is capable of detecting rejection in orthotopic cardiac transplants in which labeled lymphocytes circulating in the blood pool may reduce sensitivity, the present study was performed in which canine orthotopic cardiac transplants were evaluated in vivo. Immunosuppression was maintained with cyclosporine A (10-20 mg/kg/day) and prednisone (1 mg/kg/day) for 2 wk after transplantation. Subsequently, therapy was tapered. Five successful allografts were evaluated scintigraphically every 3 days after administration of 100-350 microCi 111In autologous lymphocytes. Correction for labeled lymphocytes circulating in the blood pool, but not actively sequestered in the allografts was accomplished by administering 3-6 mCi 99mTc autologous erythrocytes and employing a previously validated blood-pool activity correction technique. Cardiac infiltration of labeled lymphocytes was quantified as percent indium excess (%IE), scintigraphically detectable 111In in the transplant compared with that in blood, and results were compared with those of concomitantly performed endomyocardial biopsy. Scintigraphic %IE for hearts not undergoing rejection manifest histologically was 0.7 +/- 0.4. Percent IE for rejecting hearts was 6.8 +/- 4.0 (p less than 0.05). Scintigraphy detected each episode of rejection detected by biopsy. Scintigraphic criteria for rejection (%IE greater than 2 s.d. above normal) were not manifest in any study in which biopsies did not show rejection. Since scintigraphic results with 111In-labeled lymphocytes were concordant with biopsy results in orthotopic cardiac transplants, noninvasive detection of graft rejection in patients should be attainable with the approach developed

  12. The effects of indium-111 decay on pBR322 DNA

    International Nuclear Information System (INIS)

    Sahu, S.K.; Adelstein, S.J.; Makrigiorgos, G.M.; Baranowska-Kortylewicz, J.

    1995-01-01

    We have compared the effectiveness in causing DNA strand breaks of 111 In bound to DNA or free in aqueous solution with that of γ rays. Supercoiled DNA from pBR322 plasmid labeled with [ 3 H]thymidine was purified and mixed with 111 InCl 3 in the absence of presence of diethylenetriaminepentaacetic dianhydride (DTPA), a metal chelator which prevents the binding of indium to DNA. The reaction mixtures were stored at 4 degrees C to accumulate radiation dose from the decay of 111 In. The DNA was then resolved by gel electrophoresis into supercoiled, nicked circular and linear forms, representing undamaged DNA, single-strand breaks (SSBs) and double-strand breaks (DSBs), respectively. The D o values of pBR322 DNA exposed to γ radiation from an external 137 Cs source and the decay of 111 In dispersed in solution (+DTPA) are 3.1 ± 0.1 and 2.8 ± 0.1 Gy, respectively. In terms of accumulated 111 In disintegrations cm -3 of plasmid DNA solution, the D o value is 15.3 (± 0.7) x 10 10 disintegrations in the absence of DTPA and 38.2 (± 1.1) x 10 10 disintegrations in its presence. Since only 14.6 ± 5% of the 111 In was bound to DNA in the absence of DTPA, an effective D o for bound 111 In of 3.4 (± 1.1) x 10 10 disintegrations is obtained. The 11-fold (range 9- to 17-fold) increased effectiveness of this Auger electron emitter when in proximity to DNA appears to be due mainly to the higher yield of SSBs. 34 refs., 4 figs., 3 tabs

  13. Effect of antibiotic therapy on the sensitivity of indium-111-labeled leukocyte scans

    International Nuclear Information System (INIS)

    Datz, F.L.; Thorne, D.A.

    1986-01-01

    Although 111 In-labeled leukocytes have been shown to be a useful technique for detecting infection, it has been postulated that antibiotic therapy may reduce the sensitivity of the leukocyte scan. Many patients with suspected bacterial infections are placed on antibiotics before a definite site of infection has been identified. Three hundred twelve leukocyte scans on 271 patients were retrospectively reviewed and classified as positive or negative, and as to whether or not they were being treated with antibiotics at the time the leukocyte scan was performed. The overall sensitivity, considering all 312 studies, was 90%. One hundred sixty-nine patient studies were on patients receiving antibiotics; 143 studies were on patients not on antibiotics. The sensitivity of the leukocyte scan was 88.7% in patients on antibiotic therapy; it was 92.1% in those who were not receiving antibiotics. The differences in sensitivity between the two groups were not significantly different (p less than 0.05). We conclude that antibiotic therapy does not affect the sensitivity of the 111 In-labeled leukocyte scan

  14. Imaging thrombus with radiolabelled monoclonal antibody to platelets

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M.; Lavender, J.P.; Needham, S.G.; Loutfi, I.; Snook, D.; Epenetos, A.A.; Lumley, P.; Keery, R.J.; Hogg, N.

    1986-12-13

    A study was conducted evaluating a method of imaging thrombus with platelets radiolabelled with a /sup 111/In labelled monoclonal antibody, P256, directed to the platelet surface glycoprotein complex IIb/IIIa. when the number of receptors occupied by P256 was less than 3% of the total available on the platelet surface, platelet function was undisturbed. P256 was radiolabelled with /sup 111/In using diethylenetriaminepenta-acetic acid, which achieved a specific activity of 185 MBq (5 mCi)/mg. No impairment of immunoreactivity was detected at this specific activity. Platelets were labelled with radiolabelled monoclonal antibody in vitro in two patients at a receptor occupancy of 6% and in vivo in six patients at a receptor occupancy of 1%. In vivo recovery and biodistribution kinetics suggested that after in vitro labelling platelets were minimally activated. The /sup 111/In kinetics recorded after intravenous P256 suggested rapid and efficient radiolabelling of platelets and gave no indication of platelet activation. Of the six patients who received intravenous P256, three had documented thrombus, two of whom gave positive results on P256 platelet scintigraphy. The third had chronic deep venous thrombosis and was scintigraphically negative.

  15. Conference on radionuclide labelled cellular blood elements

    International Nuclear Information System (INIS)

    1986-01-01

    The South African Medical Research Council presented this conference on radionuclide labelled cellular blood elements with application in atherosclerosis and thrombosis. The conference was held in Bloemfontein from 3-6 February 1986. This work only consists of the abstracts of the seminars that were delivered on the conference. The radioisotopes that occur most of the time in the abstracts include Indium 111, Indium 114, Chromium 51, Iodine 125, Iodine 131 and Carbon 14. Especially Indium 111 seems to be the method of choice for all labelling

  16. In vitro stability of EDTA and DTPA immunoconjugates of monoclonal antibody 2G3 labeled with indium-111

    Energy Technology Data Exchange (ETDEWEB)

    Reilly, R.; Lee, N.; Houle, S. (The Toronto Hospital (Canada)); Law, J.; Marks, A. (Toronto Univ., ON (Canada))

    1992-08-01

    Monoclonal antibody 2G3 directed against a high molecular weight glycoprotein on breast and ovarian cancer cells was conjugated with bicyclic DTPA (or EDTA) anhydride or benzyl isothiocyanate DTPA (benzyl DTPA) and labeled with {sup 111}In. DTPA anhydride was more reactive with the antibody than benzyl DTPA, and kinetics of labeling with {sup 111}In were more rapid for DTPA substituted 2G3 than for benzyl DTPA substituted 2G3. On the other hand, {sup 111}In-2G3 conjugates prepared using DTPA anhydride were subject to more extensive dimerization and higher losses in immunoreactivity than those prepared using benzyl DTPA. On the basis of measurement of transchelation to transferrin, the stability of {sup 111}In-2G3 prepared using DTPA anhydride or benzyl DTPA did not differ during incubation in human plasma for 6 days at 37{sup o}C. These results suggest that an important advantage of benzyl DTPA over DTPA anhydride for preparing {sup 111}In-labeled antibodies is the prevention of intermolecular (and intramolecular) crosslinking during conjugation which ultimately leads to alterations in conformation and losses in immunoreactivity of the radioimmunoconjugate. (author).

  17. Labeling cellular elements of blood with Technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Dewanjee, M.K.

    1990-08-01

    The purpose of this proposal is to develop new technique of labeling platelets and white cells with Tc-99m radionuclide. The conditions of labeling canine platelets and white cells with the lipid-soluble Tc-99m HMPAO have been optimized. The function of labeled platelets were evaluated by the determination of platelet survival time and recovery and these values were compared with that of In-111 tropolone labeled platelets. We developed the bilateral femoral catheterization model for the evaluation of platelet-thrombosis on control and heparin-bonded catheters in dogs. We are evaluating platelet thrombosis in the hollow-fiber hemodialyzer with Tc-99m and In-111 labeled platelets. We have developed the flow-loop for in vitro studies and are using a pig model for quantitation of platelet-consumption during hemodialysis. We are currently evaluating the new technique of platelet and white cell-labeling with Tc-99m and testing them in animal models of thrombosis and infection (osteo-myelitis). We are also using the Tc-99m HMPAO labeled mixed white cells in the early diagnosis (3-hour post-injection) of acute and chronic infection in patients and comparing the results with that of IN-111 oxine labeled white cells.

  18. Use of 111In-labeled autologous leukocytes to image an abdominal abscess in a horse

    International Nuclear Information System (INIS)

    Koblik, P.D.; Lofstedt, J.; Jakowski, R.M.; Johnson, K.L.

    1985-01-01

    Indium 111-labeled autologous leukocytes were used to image an abdominal abscess in a horse with a palpable abdominal mass and history of Streptococcus equi infection. A focal area of radioactivity was identified in the location corresponding to the abscess. Imaging of this focal uptake was optimal 48 hours after injection. Similar scans obtained in 2 clinically normal horses revealed no evidence of focal radioactivity in this region. The cell labeling procedure gave acceptable labeling efficiency (87.5%) but an excessive number of damaged WBC, resulting in persistent lung radioactivity on all images. No adverse effects were noted. Radiation measured in the horse and its excreta were well within acceptable limits

  19. 111Indium-labelled leucocyte scintigraphy in the diagnosis of inflammatory disease - first results

    International Nuclear Information System (INIS)

    Rovekamp, M.H.; Hardeman, M.R.; Schoot, J.B. van der; Belfer, A.J.

    1981-01-01

    In 61 patients, 66 scans were performed with 111 In-labelled autologous leucocytes to evaluate this method in the diagnosis of inflammatory disease. All scintigraphic results were compared with clinical, operative or postmortem findings. In the first 20 examinations in 19 patients, 2 scintigrams were true positive, 9 true negative and none false positive, whereas 9 scintigrams had to be considered as false negative. These false negative results were probably due to loss of viability of the labelled cells. A modified labelling technique, in which a much lower concentration of oxine was used, was employed for a further 46 examinations in 42 patients. Twenty-four scintigrams were true positive and 22 true negative, while no false positive or false negative results were observed. These results suggest that this modified technique is useful in the diagnosis of inflammatory disease. (author)

  20. Aspirin inhibition of platelet deposition at angioplasty sites: demonstration by platelet scintigraphy

    International Nuclear Information System (INIS)

    Cuningham, D.A.; Kumar, B.; Siegel, B.A.; Gilula, L.A.; Totty, W.G.; Welch, M.J.

    1984-01-01

    In-111 platelet scintigraphy was used to evaluate the effects of prior aspirin administration on the accumulation of In-111-labeled autologous platelets at sites of arterial injury resulting from iliac, femoral, or popliteal transluminal angioplasty in a nonrandomized study of 17 men. The degree of platelet localization at angioplasty sites was significantly less in nine men who had received aspirin in varying doses within the 4 days before angioplasty than in eight men who had not received aspirin for at least two weeks. The results suggest that aspirin treatment before angioplasty limits the early platelet deposition at the angioplasty site in men

  1. Indium 111 WBC scan in local and systemic fungal infections

    International Nuclear Information System (INIS)

    Haseman, M.K.; Blake, K.; McDougall, I.R.

    1984-01-01

    We describe two patients-one with a systemic fungal infection and one with a localized form-who had strikingly abnormal indium 111 leukocyte (WBC) scans. The patient with systemic disease had an abnormal WBC scan before lesions became clinically apparent

  2. In-111-labeled leukocytes in the diagnosis of rejection and cytomegalovirus infection in renal transplant patients

    International Nuclear Information System (INIS)

    Forstrom, L.A.; Loken, M.K.; Cook, A.; Chandler, R.; McCullough, J.

    1981-01-01

    Indium-111-labeled (In-111) leukocytes have been shown to be useful in the localization of inflammatory processes, including renal transplant rejection. Using previously reported labeling methods, 63 studies with this agent have been performed in 53 renal transplant patients. Indications for study included suspected rejection or cytomegalovirus (CMV) infection. Studies were performed in 33 men and 20 women, with ages ranging from 6 to 68 years. Autologous cells were normally used for labeling, although leukocytes obtained from ABO-compatible donors were used in three subjects. Rectilinear scanner and/or scintillation camera images were obtained at 24 hours after intravenous administration of 0.1 to 0.6 mCi of In-111-leukocytes. There was abnormal uptake of In-111-leukocytes in the transplanted kidney in 11 of 15 cases of rejection. In three additional cases of increased transplant uptake, CMV infection was present in two. Abnormal lung uptake was present in 13 of 14 patients with CMV infection. In four additional cases, increased lung uptake was associated with other pulmonary inflammatory disease. Increased lung activity was not seen in patients with uncomplicated transplant rejection. These results suggest that In-111-leukocyte imaging may be useful in the differential diagnosis of rejection versus CMV infection in renal transplant patients

  3. In-111-labeled leukocytes in the diagnosis of rejection and cytomegalovirus infection in renal transplant patients

    International Nuclear Information System (INIS)

    Forstrom, L.A.; Loken, M.K.; Cook, A.; Chandler, R.; McCullough, J.

    1981-01-01

    Indium-111-labelled (In-111) leukocytes have been shown to be useful in the localization of inflammatory processes, including renal transplant rejection. Using previously reported labelling methods, 63 studies with this agent have been performed in 53 renal transplant patients. Indications for study included suspected rejection or cytomegalovirus (CMV) infection. Studies were performed in 33 men and 20 women, with ages ranging from 6 to 68 years. Autologous cells were normally used for labeling, although leukocytes obtained from ABO-compatible donors were used in three subjects. Rectilinear scanner and/or scintillation camera images were obtained at 24 hours after intravenous administration of 0.1 to 0.6 mCi of In-111 leukocytes. There was abnormal uptake of In-111-leukocytes in the transplanted kidney in 11 of 15 cases of rejection. In three additional cases of increased transplant uptake, CMV infection was present in two. Abnormal lung uptake was present in 13 of 14 patients with CMV infection. In four additional cases, increased lung uptake was associated with other pulmonary inflammatory disease. Increased lung activity was not seen in patients with uncomplicated transplant rejection. These results suggest that In-111-leukocyte imaging may be useful in the differential diagnosis of rejection versus CMV infection in renal transplant patients

  4. Clinical usage of indium-111 labeled leukocyte scintigraphy and technetium-99m methylene diphosphonate scintigraphy in patients with total hip replacement

    International Nuclear Information System (INIS)

    Terauchi, Takashi; Uno, Kimiichi; Yuyama, Takuo; Seto, Kazuhiko; Arimizu, Noboru; Suguro, Tohru; Moriya, Hideshige; Uematsu, Sadao.

    1988-01-01

    Tc-99m methylene diphosphonate (MDP) scintigraphy and In-111 labeled leukocyte scintigraphy were done in 13 patients with total hip replacement in order to determine the presence of prosthetic infection. Tc-99m MDP scintigraphy was done in 11 patients (12 studies). In-111 labeled leukocyte scintigraphy was done in 13 patients (14 studies). Tc-99m MDP imaging showed diffuse accumulation of the radionuclide in all of the 3 infected lesions, but focal one in 5 of the 7 noninfected lesions with a specificity of 33.3 %, sensitivity of 100 %, overall accuracy of 50 %. In-111 labeled leukocyte normally accumulates in the spleen, the liver, and the bone marrow. Before insertion of a stemmed prosthesis, the local bone marrows were reamed out in all of our cases. Thus, no radioactive accumulation would be expected in the lesions with prosthesis unless infected. However, if the prosthesis is infected, increased uptake of In-111 would be seen as a result of the accumulation of leukocyte. In-111 labeled leukocyte imaging showed abnormal accumulation of In-111 in all of the 4 infected lesions and no accumulation in all of the 10 noninfected lesions with a specificity of 100 %, sensitivity of 100 %, overall accuracy of 100 %. We conclude that In-111 labeled leukocyte scintigraphy might be useful in evaluating prosthetic infection in a patient with total hip replacement. (author)

  5. /sup 111/In autologous leucocytes in the diagnosis and assessment of inflammatory bowel disease. [Tropolone

    Energy Technology Data Exchange (ETDEWEB)

    Saverymuttu, S.H.; Peters, A.M.; Chadwick, V.S.; Hodgson, H.J.; Lavender, J.P. (Hammersmith Hospital, London (UK))

    1982-01-01

    Indium-111 autologous leukocyte scanning is now established as an effective method of localising sepsis (Ascher and others, 1980). In view of the extensive leucocyte infiltration of the intestinal wall in inflammatory bowel disease, the authors have prospectively studied the use of indium-111 labelled white cells in a variety of inflammatory bowel disorders. Leukocytes were labelled in 68 patients using /sup 111/In acetylacetonate and in 18 patients /sup 111/In tropolone. Crude mixed leukocytes preparations were used in 74 patients and pure neutrophil preparation used in 12 patients. Gamma scans over the abdomen were performed from 40 min later after re-injection of the labelled cells and assessed. /sup 111/In-tropolone labelling appeared to offer the advantage over /sup 111/In-acac labelling in localising inflamed bowel earlier. The technique of /sup 111/In-leukocyte scanning offers several advantages over the alternative technique of imaging diseased bowel using gallium-67 citrate. Indium-111 leukocyte scanning provides a novel approach to the problem of diagnosis and assessment of inflammatory bowel disease. It is non-invasive, requires no bowel preparation and this is safe in the acutely sick patient where conventional radiological imaging methods may be hazardous. /sup 111/In faecal excretion provides an objective assessment of disease activity which should prove useful in evaluating treatment regimes.

  6. 111In-labeled platelets: effects of heparin on uptake by venous thrombi and relationship to the activated partial thromboplastin time

    International Nuclear Information System (INIS)

    Fedullo, P.F.; Moser, K.M.; Moser, K.S.; Konopka, R.; Hartman, M.T.

    1982-01-01

    The goal of heparin therapy in deep vein thrombosis is to prevent thrombus extension. The relationship between thrombus extension and the results of coagulation tests used to monitor heparin therapy is unclear. To explore this relationship, we studied the effect of several heparin regimens on the accretion of 111 In-labeled platelets on fresh venous thrombi, as detected by gamma imaging, and monitored the activated partial thromboplastin time (APTT). Six dogs were treated with a 300-U/kg bolus of heparin followed by a 90-U/kg/hour heparin infusion, a dose of heparin sufficient to increase the APTT to levels greater than eight times baseline (APTT ratio); platelet accretion (thrombus imaging) occurred only after the heparin effect was reversed with protamine sulfate. Nineteen dogs were treated with a 150-U/kg bolus of heparin followed by a 4-hour, 45-U/kg/hour heparin infusion; a thrombus was demonstrated only after protamine injection in 12 (mean APTT ratio 1.3 +/- 0.19) and before protamine injection in seven. In thirteen of these 19 dogs, 30 minutes separated the platelet injection from heparin therapy, while in six this duration was less than 30 minutes. In four of these six dogs, thrombi were demonstrated before protamine therapy and at APTT ratios greater than 3.0. Finally, 10 dogs were treated with a 100-U/kg bolus followed by a 3-hour, 50-U/kg/hour heparin infusion, after which the APTT was allowed to return to baseline values spontaneously. In all 10 dogs, a thrombus was demonstrated only after cessation of the heparin infusion, and at a mean APTT ratio of 1.4 +/- 0.15 times baseline. These results suggest that, except with very early platelet injection, platelet accretion by thrombi is consistently inhibited by heparin at APTT ratios greater than 2.5. Platelet accretion by venous thrombi occurs within narrow limits of heparin effect as reflected by the APTT

  7. Scintigraphy with /sup 111/In-labeled leukocytes. Simplified procedure for labeling

    Energy Technology Data Exchange (ETDEWEB)

    Terada, Hitoshi; Shiire, Yasushi; Koizumi, Kiyoshi; Aburano, Tamio; Tonami, Norihisa; Hisada, Kin-ichi

    1987-12-01

    To utilize /sup 111/In leukocytes in a routine work, simplified procedure for sterile leukocytes preparation and labeling with water soluble oxine sulfate was performed. Viability and chemotaxis of leukocytes were maintained during separation and labeling. Chelated rate of /sup 111/In with oxine sulfate was 93.5 %. Labeling efficiency of /sup 111/In leukocytes was 93.8 %. Obvious blood pool images due to remaind erythrocytes were not observed. /sup 111/In labeled leukocytes showed good migration into inflammatory focci.

  8. Detection of acute synthetic vascular graft infection with IN-111 labeled leukocyte imaging

    International Nuclear Information System (INIS)

    Alazraki, N.; Dries, D.; Lawrence, P.; Murphy, K.; Kercher, J.; Datz, F.; Christian, P.; Taylor, A.

    1985-01-01

    Synthetic vascular graft infection is characterized by late diagnosis due to indolent and nonspecific symptoms. Reported data on accuracy of In-111 labeled leukocyte imaging to identify vascular graft infection is sparse and conflicting. The purpose of this animal study was to clarify the accuracy of detection of early graft infection using a mixed population of In-111 labeled leukocytes. Twelve mongrel dogs received dacron aortic interposition grafts. Seven grafts were contaminated at surgery by topical ATCC S. aureus, 10/sup 8/ organisms per ml. Six control animals received no graft contamination Mixed population In-111 homologous leukocyte labeling was performed followed by imaging at 24 and 48 hours following intravenous injection of 250 μCi In-111 leukocytes. Scans were done on Day 2 post-surgery. Infected dogs were sacrificed following Indium imaging; control dogs were rescanned at 3 weeks postop and sacrificed thereafter. Autopsy results were correlated with scans, yielding sensitivity 71%, specificity 100%, accuracy 85% for In-111 leukocyte imaging to detect early graft infection. False positive leukocyte imaging in the early postop period was not a problem. At autopsy all 5 dogs with infected grafts and positive scans had gross pus. The 2 dogs with false negative scans showed no gross pus at autopsy; cultures were positive for S. aureus in all 7 dogs. Scans at 2 days and 3 weeks post-surgery were true negatives in all 6 control dogs. These data suggest a high level of clinical reliability of leukocyte imaging for early graft infection detection

  9. Activated platelets in carotid artery thrombosis in mice can be selectively targeted with a radiolabeled single-chain antibody.

    Directory of Open Access Journals (Sweden)

    Timo Heidt

    Full Text Available BACKGROUND: Activated platelets can be found on the surface of inflamed, rupture-prone and ruptured plaques as well as in intravascular thrombosis. They are key players in thrombosis and atherosclerosis. In this study we describe the construction of a radiolabeled single-chain antibody targeting the LIBS-epitope of activated platelets to selectively depict platelet activation and wall-adherent non-occlusive thrombosis in a mouse model with nuclear imaging using in vitro and ex vivo autoradiography as well as small animal SPECT-CT for in vivo analysis. METHODOLOGY/PRINCIPAL FINDINGS: LIBS as well as an unspecific control single-chain antibody were labeled with (111Indium ((111In via bifunctional DTPA ( = (111In-LIBS/(111In-control. Autoradiography after incubation with (111In-LIBS on activated platelets in vitro (mean 3866 ± 28 DLU/mm(2, 4010 ± 630 DLU/mm(2 and 4520 ± 293 DLU/mm(2 produced a significantly higher ligand uptake compared to (111In-control (2101 ± 76 DLU/mm(2, 1181 ± 96 DLU/mm(2 and 1866 ± 246 DLU/mm(2 indicating a specific binding to activated platelets; P<0.05. Applying these findings to an ex vivo mouse model of carotid artery thrombosis revealed a significant increase in ligand uptake after injection of (111In-LIBS in the presence of small thrombi compared to the non-injured side, as confirmed by histology (49630 ± 10650 DLU/mm(2 vs. 17390 ± 7470 DLU/mm(2; P<0.05. These findings could also be reproduced in vivo. SPECT-CT analysis of the injured carotid artery with (111In-LIBS resulted in a significant increase of the target-to-background ratio compared to (111In-control (1.99 ± 0.36 vs. 1.1 ± 0.24; P < 0.01. CONCLUSIONS/SIGNIFICANCE: Nuclear imaging with (111In-LIBS allows the detection of platelet activation in vitro and ex vivo with high sensitivity. Using SPECT-CT, wall-adherent activated platelets in carotid arteries could be depicted in vivo. These results encourage further studies elucidating the role of

  10. Murine eosinophils labeled with indium-111 oxine: localization to delayed hypersensitivity reactions against a schistosomal antigen and to lymphokine in vivo

    International Nuclear Information System (INIS)

    Rand, T.H.; Clanton, J.A.; Runge, V.; English, D.; Colley, D.G.

    1983-01-01

    We have evaluated a method for quantitation of eosinophil migration to stimuli in vivo. Upon transfusion into normal syngeneic mice, 111In-labeled eosinophils had an intravascular half-life of 9.5 hr and distributed predominantly into spleen, bone marrow, and liver. In either Schistosoma mansoni-infected mice or recipients of lymphoid cells from infected mice, intradermal (ear pinna) injection of the schistosomal egg antigenic preparation (SEA) elicited time-dependent accumulation of 111In-labeled eosinophils detectable by either gamma scintillation counting of tissue samples or by nuclear medicine external imaging. Intradermal administration of a lymphokine fraction (containing eosinophil stimulation promoter activity) similarly caused accumulation of 111In-labeled eosinophils. Both reactions depended on the concentration of stimulus (SEA or lymphokine). 111In-labeled neutrophils or macrophages or 125I-albumin did not preferentially accumulate at the reactions examined to the extent found with 111In-labeled eosinophils, indicating that localization of label depends on an active process and is due to eosinophils rather than a contaminating cell type. The method was used to estimate how long eosinotactic lymphokine remained at dermal sites: 60% of initial activity was present 12 hr after injection. The model is discussed with regard to the role of lymphokines in hypersensitivity reactions with eosinophil involvement, such as the granulomatous response to S. mansoni eggs

  11. Potential application of labeled antibodies for thrombus detection

    Energy Technology Data Exchange (ETDEWEB)

    Ezekowitz, M.D.; Coller, B.S.; Srivastava, S.C.

    1986-01-01

    Labeling platelets with monoclonal antibodies in whole blood for imaging thrombi is less cumbersome than the established /sup 111/In-oxine method. 7E3, a murine monoclonal antibody directed against glycoprotein IIb and/or IIIa on both human and dog platelets was used to label canine platelets. Thrombi were induced by transcatheter placement of a copper coil followed by electrocoagulation. 7E3 was iodinated with /sup 131/I and labelled with /sup 111/In using 7E3-DTPA conjugate. Whole blood was incubated with 0.5 - 1.0 ..mu..g labeled 7E3/mL blood. In 4/4 dogs, experimental deep vein thrombi were identified using both /sup 131/I-and /sup 111/In-labeled 7E3 within 5-30 min after injection. For both isotopes, 1 h blood clearance was 54 + - 9%. In 1/3 dogs, experimental coronary thrombus could be identified ex vivo at 4 h. Clot to blood ratios ranged between 7 to 13:1. Using the /sup 111/In-oxine method, 0/3 coronary thrombi were seen. Thus, /sup 131/I-and /sup 111/In-labeled 7E3 may be used to readily identify peripheral venous thrombi. For reliable and prompt identification of coronary thrombi, more rapid clearance of the labeled platelets is required.

  12. Indium 111. Radiation protection

    International Nuclear Information System (INIS)

    Grafstroem, G.; Joensson, B.A.; Strand, S.E.

    1989-01-01

    The radiopharmaceutucal 111 In-oxine is used in labelling of different blood cells and proteins. Due to its liquid state, there is always a risk for contamination during handling procedures. The aim of the project was to evaluate the contamination risks, when using this radiopharmaceutical. The investigation includes calculations of the absorved dose to the skin after a contamination of 111 In-oxine, including the radionuclide impurity 114 In m / 114 In. Investigations of 288 protection gloves shows that there is always a risk for contamination, when working with 111 In-oxine. On the protection gloves, we found activities normally ranging from a 100 Bq up to a few kBq. Noticeable is the contamination on the vials, already before their use. Besides 111 In we found most of the radionuclides used in nuclear medicine, with activities up to tens of kBq. The radionuclide impurity was cleary detectable but below the recommended value. The penetration of 111 In-oxine protection gloves of latex was negligible. Measurements of penetration in skin was evaluated with two independent methods; in vivo using a surface barrier detector, and by autoradiography. The measured penetration was less than a few micrometers. Calculation from the experimental contamination values show that the absorbed dose to the basal cell layer could be in order of several Gy. (authors)

  13. The role of indium-111 antimyosin (Fab) imaging as a noninvasive surveillance method of human heart transplant rejection

    International Nuclear Information System (INIS)

    De Nardo, D.; Scibilia, G.; Macchiarelli, A.G.

    1989-01-01

    The identification of rejection after heart transplantation in patients receiving cyclosporine immunosuppressive therapy requires the endomyocardial biopsy, an invasive method associated with a finite morbidity. To evaluate the role of indium-111 antimyosin (Fab) scintigraphy as a noninvasive surveillance method of heart transplant rejection, the Fab fragment of murine monoclonal antimyosin antibodies labeled with indium-111 was administered intravenously in 30 scintigraphic studies to 10 consecutive heart transplant recipients. Endomyocardial biopsy specimens were obtained 72 hours after each scintigraphic study. Nineteen scintigraphic studies had negative findings; no false negative finding was obtained. Eleven antimyosin scintigraphic studies had positive findings, and in these studies endomyocardial biopsy revealed mild rejection in two cases, moderate acute rejection with myocyte necrosis in two cases, myocyte necrosis as a consequence of ischemic injury in six cases, and possibly cytotoxic damage in one case. Antimyosin scintigraphy may represent a reliable screening method for the surveillance of heart transplant patients. In the presence of a negative finding from antimyosin scintigraphy, it may be possible to avoid endomyocardial biopsy. Conversely, in patients who have a positive finding from antimyosin scintigraphy, the endomyocardial biopsy is mandatory to establish the definitive diagnosis by histologic examination of the myocardium

  14. Indium-111-chloride and three-phase bone scintigraphy: A comparison for imaging experimental osteomyelitis

    International Nuclear Information System (INIS)

    Hoskinson, J.J.; Daniel, G.B.; Patton, C.S.

    1991-01-01

    To investigate the utility of indium-111-chloride ( 111 In-Cl) imaging in detecting osteomyelitis complicating surgical or fracture sites, the proximal tibia of 11 dogs were experimentally infected with Staphylococcus aureus after creation of a cortical defect. The contralateral limb served as a sham-operated control. Animals were serially imaged by radiography, three-phase technetium-99m-methylene diphosphonate (99mTc-MDP) scintigraphy, and 111 In-Cl scintigraphy. There was a significant difference between infected (1.93) and noninfected (1.32) limb's tibia/femur count density ratios on 24-hr (p = 0.0001) and 72-hr (p = 0.0001) 111 In-Cl images. A smaller difference was found for 99mTc-MDP bone-phase tibia/femur ratios (p = 0.0199). Using receiver operator characteristic analysis of tibia/femur ratios, a sensitivity of 61%, specificity of 88%, and positive (75%) and negative (79%) predictive values were determined for the 24-hr 111 In-Cl images. Indium-111-chloride was superior to 99mTc-MDP in differentiating infected and noninfected operative sites

  15. 111indium-antimyosin immunoscintigraphy in suspected myocarditis

    International Nuclear Information System (INIS)

    Krause, T.; Schuemichen, C.; Joseph, A.; Moser, E.; Zeiher, A.

    1991-01-01

    111 Indium-monoclonal antimyosin scans were carried out in 21 patients with suspected myocarditis, confirmed by reduced ejection volume, pericardial effusion and clinical follow up in 12 patients. Coronary heart disease was excluded angiographically in all cases. Quantitative evaluation of myocardial 111 In-antimyosin accumulation 48 hours after injection showed a pathological uptake in 10/12 patients with increased heart/lung ratios (Q 48 >1,58). Ratios were also elevated in 2 patients with cardiomyopathy, 2 suffering from vasculitis and 1 with dermatomyositis. Four patients without proven cardiac disease had normal ratios (Q 48 ≤1,58). Examination after 24 hours was of limited value, depending on the residual blood pool activity. Visual analysis of the scans showed a high interobserver variation despite a positive correlation with quantitative analysis (48 h p.i.: r=0,72; p 111 In-antimyosin scan as a screening method prior to myocardial biopsy. However, scintigraphy cannot definitely elucidate the cause of myocardial damage. Therefore, myocardial biopsy is still recommended after positive antimyosin scans. (orig.) [de

  16. Technetium-99m as alternative to produce somatostatin-labeled derivatives: comparative biodistribution evaluation with 111In-DTPA-octreotide

    International Nuclear Information System (INIS)

    Melo, Ivani B.; Buchpiguel, Carlos Alberto; Ueda, Laura T.; Araujo, Elaine B. de; Muramoto, Emiko; Barboza, Marycel F. de; Mengatti, Jair; Silva, Constancia P.G. da

    2008-01-01

    Synthetic somatostatin (SST) analogues have been used in the preparation of receptor-specific radiopharmaceuticals for diagnostic and therapy of neuroendocrine (NE) tumors. 111 In-DTPA-Octreotide (OctreoScan®) has found useful for imaging a range of tumors, including NE cancer, carcinoide and lymphoma. Unfortunately, 111 In is a high-cost cyclotron produced radioisotope with gamma emission not so suitable for scintigraphic images and for dosimetry like 99m Tc. This work studied the labeling conditions with 99m Tc and biological distribution in Swiss mice of two SST analogs (HYNIC-Tyr 3 -Octreotide and HYNICTyr 3 - Octreotate) and compared the biodistribution pattern with 111 In-DTPA-Octreotide. 99 mTc-HYNIC-Tyr 3 - Octreotate ( 99m Tc-HYNIC-TATE) and 99m Tc-HYNIC-Tyr 3 -Octreotide ( 99m Tc-HYNIC-OCT) were produced by labeling conditions using tricine and EDDA as coligands. 111 In-DTPA-Octreotide ( 111 In-DTPA-OCT) was produced by labeling DTPA-Octreotide with 111 InCl 3 (Nordion). Radiochemical purity of labeled preparations was determined by ITLC-SG. Biological distribution studies were performed after injection of radiopharmaceuticals on Swiss mice. Labeling procedures resulted on high radiochemical yield for all three preparations and the labeled products presented high in vitro stability. Biological distribution studies evidenced similar general biodistribution of 99m Tc-labeled peptides when compared with indium-labeled peptide with fast blood clearance and elimination by urinary tract. Kidneys uptake of 99 mTc-HYNIC-TATE are similar to 111 In-DTPA-Octreotide, and both are significantly higher than 99 mTc-HYNIC-OCT. All labeled peptides presented similar uptake on liver, but the retention in time at intestines, particularly at large intestine, was more expressive for 111 In-labeled peptide. The %ID of 99m Tc-HYNIC-OCT and 99m Tc-HYNIC-TATE in organs with high density of SST receptors like pancreas and adrenals were significant and similar to obtained for 111

  17. Effect of unlabelled monoclonal antibody (MoAb) on biodistribution of /sup 111/Indium labelled (MoAb)

    Energy Technology Data Exchange (ETDEWEB)

    Lamki, L M; Murray, J L; Rosenblum, M G; Patt, Y Z; Babaian, Richard; Unger, M W

    1988-08-01

    We have evaluated immunoscintigraphy in cancer patients using four /sup 111/In-labelled murine monoclonal antibodies (MoAb): 96.5 (anti-P97 of melanoma), ZME-018 (anti-high molecular weight antibody of melanoma), ZCE-025 (anti-CEA for colon cancer) and PAY-276 (anti-prostatic acid phosphatase for prostatic cancer). The effect of increasing the doses of unlabelled MoAb (co-infused with 1 mg labelled MoAb) on the relative body distribution of each labelled MoAb was assessed. Localization in the liver decreased significantly in all cases, with increasing MoAb dose, except for ZME-018. Localization in other organs increased significantly as the liver activity decreased. The spleen activity, however, fell in the case of MoAb ZME-018. Blood-pool activity increased with MoAb dose in all four MoAbs. These findings correlated with the rise in the detection rate of metastases, the plasma half-life, and other pharmacokinetic parameters. However, the dose level at which this correlation occurred varied with each antibody. These data demonstrate the co-infusion of unlabelled MoAb with /sup 111/In-labelled MoAb could alter the organ distribution, pharmacokinetics and tumour uptake in a favourable manner, though the degree to which this occurs depends on the antibody in question.

  18. Iliac artery mural thrombus formation. Effect of antiplatelet therapy on 111In-platelet deposition in baboons

    International Nuclear Information System (INIS)

    Hanson, S.R.; Paxton, L.D.; Harker, L.A.

    1986-01-01

    To measure the rate, extent, and time course of arterial mural thrombus formation in vivo and to assess the effects of antiplatelet therapy in that setting, we have studied autologous 111 In-platelet deposition induced by experimental iliac artery aneurysms in baboons. Scintillation camera imaging analyses were performed at 1, 24, 48, and 72 hours after implantation of the device. Correction for tissue attenuation was determined by using a small, comparably located 111 In source implanted at the time of surgery. In five animals, 111 In-platelet activity accumulated progressively after device implantation, reaching a maximum after the third day. Repeat image analysis carried out 2 weeks after the surgical procedure also showed progressive accumulation of 111 In-platelets over 3 days but at markedly reduced amounts as compared with the initial study. In five additional animals, treatment with a combination of aspirin and dipyridamole begun 1 hour after surgical implantation reduced 111 In-platelet deposition to negligible levels by the third day. Although platelet survival time was shortened and platelet turnover was reciprocally increased in all operated animals, platelet survival and turnover were not affected by antiplatelet therapy. We conclude that, in contrast to platelet survival and turnover measurements, 111 In-platelet imaging is a reliable and sensitive method for localizing and quantifying focal arterial thrombi and for assessing the effects of antiplatelet therapy

  19. The haemostatic effect of 51Cr-labelled blood platelets

    International Nuclear Information System (INIS)

    Bjoernson, J.; Aursnes, I.

    1977-01-01

    The haemostatic effect of 51 Cr-labelled platelets was studied in 5 rabbits made thrombocytopenic (35,000/μl blood) by whole body ionizing irradiation. Bleeding times were recorded after standardized cuts on the inner side of the rabbit's ear, a method with an acceptable reproducibility. The animals were then each transfused with concentrates of labelled pletelets from 2 healthy donor rabbits. This increased the platelet counts to about 2 x 10 5 /μl blood. Bleeding time values were markably prolonged before transfusion and became normalized when tested 1 and 4 h after transfusion. In 3 control experiments, where unlabelled platelet rich plasma was transfused to thrombocytopenic recipients, a similar shortening of the bleeding time was observed. It is concluded that 51 Cr-labelled platelets retain haemostatic ability comparable to non-labelled platelets, when circulating in a recipient animal. (author)

  20. 111In autologous leucocytes in the diagnosis and assessment of inflammatory bowel disease

    International Nuclear Information System (INIS)

    Saverymuttu, S.H.; Peters, A.M.; Reavy, H.J.; Danpure, H.J.; Osman, S.; Chadwick, V.S.; Hodgson, H.J.; Lavender, J.P.

    1982-01-01

    111 In-labelled leucocytes were used to obtain gamma camera images of inflamed of bowel in a wide variety of inflammatory bowel disease. No false positive scans were observed in the irritable bowel syndrome and in bowel malignancy. All patients with moderate or severely active disease had positive scans. Faecal excretion of 111 Indium increased with disease severity. 111 In-tropolone labelling appeared to offer the advantage over 111 In-acac labelling in localising inflamed bowel earlier. In many cases the bowel was imaged within 40 min of re-injection of the leucocytes. 111 In-leucocyte scanning provides a novel approach to the problem of diagnosis and assessment of inflammatory bowel disease. It is non-invasive, requires no bowel preparation and thus is safe in the acutely sick patient where conventional radiological imaging methods may be hazardous. 111 Indium faecal excretion provides an objective assessment of disease activity which should prove useful in evaluating treatment regimes

  1. Palmitic acid-labeled lipids selectively incorporated into platelet cytoskeleton during aggregation

    International Nuclear Information System (INIS)

    Packham, M.A.; Guccione, M.A.; Bryant, N.L.; Livne, A.

    1990-01-01

    Previous experiments showed that during the early stages (20-30 seconds) of aggregation induced by adenosine diphosphate (ADP, 2 microM) or thrombin (0.1 U/mL) of rabbit or human platelets prelabeled with [3H]palmitic acid, labeled lipid became associated with the cytoskeleton isolated after lysis with 1% Triton X-100, 5 mM EGTA [ethylene glycol-bis-(beta-aminoethyl ether)]-N,N,N',N'-tetra-acetic acid. The association appeared to be related to the number of sites of contact and was independent of the release of granule contents. We have now investigated the nature of the labeled lipids by thin-layer and column chromatography and found differences between the distribution of the label in intact platelets (both stimulated and unstimulated) and the isolated cytoskeletons. In both species, and with either ADP or thrombin as aggregating agent, 70-85% of the label in both intact platelets and in the cytoskeletons was in phospholipids. The distribution of label among the phospholipids in the cytoskeletons was similar to that in intact platelets except that the percentage of label in phosphatidylcholine was significantly higher in the cytoskeletons of human platelets than in the intact platelets, and the percentage of label in phosphatidylserine/phosphatidylinositol was significantly lower in the cytoskeletons of rabbit platelets and thrombin-aggregated human platelets than in intact platelets. The cytoskeletons contained a lower percentage of label in triacylglycerol, diacylglycerol, and cholesterol ester than the intact platelets. Contrary to a report in the literature, we found no evidence for the incorporation of diacylglycerol and palmitic acid into the cytoskeleton

  2. Pharmacokinetics of chimeric L6 conjugated to indium-111- and yttrium-90-DOTA-peptide in tumor-bearing mice

    International Nuclear Information System (INIS)

    DeNardo, S.J.; Zhong, G.R.; Salako, Q.

    1995-01-01

    A bifunctional chelating agent, DOTA-Gly 3 -L-(p-isothiocyanato)-phenylalanine amide (DOTA-peptide-NCS), was studied in nude mice bearing human breast cancer xenografts (HBT 3477) to determine its potential for radioimmunoconjugate therapy. Indium-111 and yttrium-90 were attached to an anti-adenocarcinoma chimeric L6 (ChL6) monoclonal antibody (MAb) after pre-chelation to the DOTA-peptide-NCS and the desired neutral radiochelates were obtained by purification. The unique characteristic of the DOTA-peptide-NCS to form neutral complexes with trivalent metals was utilized to separate the resulting 111 In and 90 Y radiochelates from excess chelating agent and other anionic by-products resulting from metal impurities. The purified radiochelates were then conjugated to ChL6. The paramacokinetics of 111 In- and 90 Y-DOTA-peptide-ChL6 were obtained for 5 days after injection in nude mice bearing HBT 3477 xenographs. The results were compared with the pharmacokinetics of 125 I-ChL6 obtained in the same mouse model. The whole-body clearance of 125 I-ChL6, 90 Y-and 111 In-DOTA-peptide-ChL6 was monoexponential with biologic half-times of 92, 104 and 160 hr, respectively. Blood clearances of the three radiopharmaceuticals were biphasic. The radiometal immunoconjugates had greater tumor uptake and slower clearances. Indium-111- and 90 Y-DOTA-peptide-ChL6 can be produced at high specific activity with fewer than one chelate per MAb by using a pre-labeling method that permits radiochelate purification by charge selection. Studies in mouse xenografts indicate that tumor uptake in enhanced and a favorable therapeutic index is achieved using these agents. 29 refs., 7 figs., 2 tabs

  3. In-111-labeled leukocyte scintigraphy in suspected orthopedic prosthesis infection: comparison with other imaging modalities

    International Nuclear Information System (INIS)

    Magnuson, J.E.; Brown, M.L.; Hauser, M.F.; Berquist, T.H.; Fitzgerald, R.H. Jr.; Klee, G.G.

    1988-01-01

    When infection of prosthetic orthopedic implants is suspected, optimal management requires accurate confirmation or exclusion of infection. The authors retrospectively studied 98 patients with possible infection who underwent scanning with indium-111-labeled white blood cells (WBCs) and subsequently underwent surgery within 14 days. At surgery, 50 patients had infections, as determined by means of culture or histologic results. The diagnostic accuracy of In-111 scanning was compared with that of plain radiography, arthrography, three-phase bone scanning, and various clinical and laboratory findings classically associated with infection. Positive findings on In-111 WBC scans and elevated erythrocyte sedimentation rates were found to be the most predictive variables in the diagnosis of septic prostheses (P less than or equal to .001 and P less than or equal to .002, respectively). Likelihood ratio analysis more clearly demonstrated the superiority of In-111 WBC scanning, with positive and negative scans yielding likelihood ratios of 5.0 and 0.16, respectively

  4. Dynamic interaction of 111indium-labeled monoclonal antibodies with surface antigens of solid tumors visualized in vivo by external scintigraphy

    International Nuclear Information System (INIS)

    Hwang, K.M.; Keenan, A.M.; Frincke, J.; David, G.; Pearson, J.; Oldham, R.K.; Morgan, A.C. Jr.

    1986-01-01

    Two 111 indium-labeled murine monoclonal antibodies (MoAb), D3 and 9.2.27, directed to tumor antigens of L-10 hepatocarcinoma and human melanoma, respectively, selectively localized antigen-positive target cells in guinea pigs and nude mice. The fate of MoAb differed in the two antigen-antibody systems after reacting with their corresponding tumor antigens in vivo as reflected by patterns of distribution and turnover in vivo. The 9.2.27 localized in melanoma xenograft in nude mice after intravenous administration with slow loss from tumor but more rapid loss from normal tissues and thus demonstrated optimal imaging of small tumors (approximately equal to 5 mm) between 3 and 6 days after injection of the radiolabeled antibody. In contrast, D3 demonstrated a biphasic localization in guinea pig L-10 hepatocarcinoma with a maximal activity on the 2d day after administration and showed rapid loss from both tumor and normal tissues. Nonspecific localization of antibodies in liver and in kidney was found both in syngeneic (nude mice) and xenogeneic (guinea pig) hosts but was more pronounced in the xenogeneic species. These results indicate that the nature of the antigen-antibody interaction may be of importance in selecting MoAb for both diagnosis and therapy of malignant diseases

  5. Platelet kinetics: the state of the art

    International Nuclear Information System (INIS)

    Heyns, A. duP

    1984-01-01

    In this paper an overview of the state of the art of platelet kinetics 1982 is presented. The subjects considered include a discussion of the advantages and disadvantages of some of the many radionuclide platelet labels, viz 51 Cr, 111 In, focussing briefly on models for analysis of platelets survival. (Auth.)

  6. Noninvasive detection of coronary thrombi with 111In platelets: concise communication

    International Nuclear Information System (INIS)

    Bergmann, S.R.; Lerch, R.A.; Mathias, C.J.; Sobel, B.E.; Welch, M.J.

    1983-01-01

    The need for rapid, definitive identification of coronary thrombosis has been intensified by the advent of thrombolytic therapy and by interest in the role of thrombosis in the etiology of coronary artery disease. To determine whether platelet thrombi can be detected noninvasively with 111 In platelets, a method was developed in which /sup 99m/Tc-tagged red blood cells were used to correct for activity within the blood attributable to platelets circulating but not associated with thrombus. In 18 dogs coronary thrombi were induced closed-chest with a copper coil introduced into the coronary artery. 111 In platelets and /sup 99m/Tc RBCs were administered either before or 1 hr after induction of thrombus, and serial scintigrams obtained. Coronary thrombus was identified readily in the processed scintigrams. In six dogs, thrombolysis was achieved with intracoronary streptokinase. In each case serial scintigraphy demonstrated resolution of the clot. The dual radiotracer technique should permit serial noninvasive delineation of the temporal relationship between platelet deposition and coronary heart disease in patients, and should facilitate the evaluation of interventions designed to prevent platelet aggregation or to lyse existing thrombi

  7. Blood clotting and platelets: a delicate balance

    International Nuclear Information System (INIS)

    Heyns, A. du P.; Loetter, M.G.; Badenhorst, P.N.

    1988-01-01

    The Medical Research Council Blood Platelet Research Unit has studied many of the facets of platelets. The research highlights of the Unit include the following: the identification of ADPase, an enzyme found in the blood vessel wall, which breaks down adenosine diphospate (ADP) to adenosine, and which inhibits platelet aggregation; the determination of the relationship between the biochemical activity of the vessel wall with the development of atherosclerosis; the development of a method to label platelets with the compound In-111-oxine; the use of labelled platelets to study platelets in the spleen: an investigation of the life-span of platelets, which revealed how aged platelets are removed from circulation, and recently a study of methods to demonstrate in vivo activation of platelets. 1 fig

  8. Sensitivity of scintigraphy with 111In-lymphocytes for detection of cardiac allograft rejection

    International Nuclear Information System (INIS)

    Eisenberg, S.B.; Eisen, H.J.; Sobel, B.E.; Bergmann, S.R.; Bolman, R.M. III

    1988-01-01

    We recently demonstrated the feasibility of noninvasive detection of cardiac allograft rejection after administration of indium-111-labeled lymphocytes. To determine the sensitivity and specificity of the technique, as well as its value for delineating the severity of rejection, we studied 16 dogs with heterotopic thoracic cardiac allografts. Five animals were evaluated while exposed to immunosuppressive agents. Animals were scanned sequentially after administration of 100-400 microCi of indium-111-labeled autologous lymphocytes. Myocardial lymphocyte infiltration was expressed as the indium excess (IE), defined as the ratio of indium activity of the transplant or native heart compared with that in blood. Scintigraphic results were compared with characteristics of simultaneously obtained endomyocardial biopsies. Among 17 biopsy documented episodes of rejection, 16 were detected scintigraphically. Among 18 biopsies with no evidence of rejection, scintigraphy was uniformly negative. Thus, the sensitivity and specificity of scintigraphy were 94 and 100%, respectively. Biopsies graded as showing no rejection were associated with an IE of 0.3 +/- 0.5 (+/- SD); those graded as mild, 2.8 +/- 1.7; those as moderate, 10.7 +/- 7.2; and those graded as indicative of severe rejection, 14.2 +/- 4.5. Thus, scintigraphy with indium-111-labeled lymphocytes sensitively and specifically detects cardiac allograft rejection and delineates the intensity of the rejection process. It should be useful clinically for assessing potential allograft rejection noninvasively

  9. [125I] radioiodinated metaraminol: A new platelet-specific labeling agent

    International Nuclear Information System (INIS)

    Ohmomo, Y.; Yokoyama, A.; Kawai, K.; Arano, Y.; Horiuchi, K.; Saji, H.; Torizuka, K.

    1985-01-01

    In our search for a platelet-specific labeling agent, metaraminol (MA), a low-toxic pharmaceutical for the treatment of hypotension and cardiogenic shock, attracted our attention. Its active incorporation and accumulation by platelets have been recognized. At first, the preparation of 125 I radioiodinated metaraminol ( 125 I-MA) was carried out using the chloramine-T method. Then, upon the harvest of platelets as platelet-rich plasma (PRP), their labeling with this new radiopharmaceutical was easily performed by incubation for 10 min at 37 0 C. The cell-labeling efficiency was dependent on cell density, reaching 63.0%+-3.1% at 2.4x10 9 cells/ml. The specific incorporation of 125 I-MA by an active transport system similar to that of 5-hydroxytryptamine (5-HT) as well as by passive diffusion was demonstrated. In vitro studies, the unaltered state of 125 I-MA-labeled platelets with their cellular functions fully retained was estimated. In vivo studies carried out in rabbits with induced thrombi in the femoral artery showed a rather rapid disappearance of the radioactivity from circulating blood, reaching a high thrombus-to-blood activity ratio of 19.8+-4.3 within 30 min of the administration of 125 I-MA-labeled autologous platelets. Thus, with the potential availability of 123 I, 123 I-MA-labeled platelets appear to be a promising agent for thrombus imaging using single-emission computed tomography (CT) studies. (orig.)

  10. Stabilised 111In-labelled DTPA- and DOTA-conjugated neurotensin analogues for imaging and therapy of exocrine pancreatic cancer

    International Nuclear Information System (INIS)

    Visser, M. de; Krenning, E.P.; Jong, M. de; Janssen, P.J.J.M.; Srinivasan, A.; Reubi, J.C.; Waser, B.; Erion, J.L.; Schmidt, M.A.

    2003-01-01

    Neurotensin (NT) receptors are overexpressed in exocrine pancreatic cancer and Ewing's sarcoma. The potential utility of native NT in cancer diagnosis and therapy is, however, limited by its rapid degradation in vivo. Therefore, NT analogues were synthesised with modified lysine and arginine derivatives to enhance stability and coupled either to DTPA, to enable high specific activity labelling with indium-111 for imaging, or to DOTA, to enable high specific activity labelling with β-emitting radionuclides, such as lutetium-177 and yttrium-90. Based on serum stability (4 h incubation at 37 C in human serum) and receptor binding affinity, the five most promising analogues were selected and further evaluated in in vitro internalisation studies in human colorectal adenocarcinoma HT29 cells, which overexpress NT receptors. All five NT analogues bound with high affinity to NT receptors on human exocrine pancreatic tumour sections. The analogues could be labelled with 111 In to a high specific activity. The 111 In-labelled compounds were found to be very stable in serum. Incubation of HT29 cells with the 111 In-labelled analogues at 37 C showed rapid receptor-mediated uptake and internalisation. The most promising analogue, peptide 2530 [DTPA-(Pip)Gly-Pro-(PipAm)Gly-Arg-Pro-Tyr-tBuGly-Leu-OH] was further tested in vivo in a biodistribution study using HT29 tumour-bearing nude mice. The results of this study showed low percentages of injected dose per gram tissue of this 111 In-labelled 2530 analogue in receptor-negative organs like blood, spleen, pancreas, liver, muscle and femur. Good uptake was found in the receptor-positive HT29 tumour and high uptake was present in the kidneys. Co-injection of excess unlabelled NT significantly reduced tumour uptake, showing that tumour uptake is a receptor-mediated process. With their enhanced stability, maintained high receptor affinity and rapid receptor-mediated internalisation, the 111 In-labelled DTPA- and DOTA-conjugated NT

  11. 99Tcsup(m)-HMPAO labelled leucocytes: comparison with 111In-tropolonate labelled granulocytes

    International Nuclear Information System (INIS)

    Peters, A.M.; Roddie, M.E.; Zacharopoulos, G.P.; George, P.; Stuttle, A.W.J.; Lavender, J.P.; Danpure, H.J.; Osman, S.

    1988-01-01

    The lipophilic complex, 99 Tcsup(m)-hexamethylpropyleneamine oxime (HMPAO) is an efficient leucocyte label, and labels granulocytes with more stability than mononuclear leucocytes. The recovery of 99 Tcsup(m)-HMPAO granulocytes was similar to 111 In-labelled granulocytes isolated and labelled in plasma using tropolone. The Tsub(1/2) of 99 Tcsup(m)-HMPAO labelled granulocytes in blood was less than that of 111 In-labelled granulocytes. The initial biodistribution of 99 Tcsup(m)-labelled leucocytes was similar to 111 In-labelled granulocytes, with a rapid initial lung transit, prominent splenic activity, bone marrow activity and minimal hepatic activity, although, unlike 111 In, 99 Tcsup(m) activity was also seen in urine, occasionally in the gallbladder, and, from about 4 h, consistently in the colon. Bone marrow activity was particularly prominent with 99 Tcsup(m). About 6% of 99 Tcsup(m) was excreted in the faeces up to 48 h after injection, and about 17% in urine up to 24 h. The time-activity curves of reticuloendothelial activity up to 24 h were broadly similar for the two labelled cell preparations. Clinical information given by the two agents was similar in 27 of 30 patients who received both. We conclude that with respect to granulocyte kinetics and clinical data, 99 Tcsup(m)-HMPAO labelled leucocytes are comparable with 111 In-tropolonate labelled granulocytes. (author)

  12. (111)Indium-transferrin for localization and quantification of gastrointestinal protein loss

    DEFF Research Database (Denmark)

    Simonsen, Jane Angel; Braad, Poul-Erik; Veje, Annegrete

    2009-01-01

    Objective. To evaluate the indium-111 ((111)In)-transferrin method as a means of localization and quantification of gastrointestinal protein loss. Methods. Fourteen patients and 15 healthy subjects underwent an (111)In-transferrin study consisting of abdominal scintigraphy, whole-body counting...... measurement and determination of plasma activity of (111)In during the course of 5 days. Two of the patients went through a subsequent chromium-51-trichloride test with analysis of radioactivity in faeces in order to compare the results of the two methods. Results. The patients had a mean+/-SEM whole-body...... loss of (111)In of 10.9+/-2.9% for 96 h, while the healthy controls lost 1.8+/-1.3% (p=0.0045). The decay in plasma activity followed biexponential kinetics. The characteristic plasma transit time was 5.0+/-1.0 h in patients and 12.1+/-1.5 h in controls (p=0.0007). Scintigraphically, patients had...

  13. [Investigations into the use of radiolabeled monoclonal antibodies for selective cell labeling in whole blood]: Progress report, March 1985-May 1988

    International Nuclear Information System (INIS)

    Thakur, M.L.

    1987-01-01

    Seventeen monoclonal antibodies (MAbs), 7 specific for human platelets and 10 specific for human polumorphonuclear leukocytes (PMNs) have been evaluated. One MAb has been identified as the antibody most suitable for canine platelets and another has been evaluted as the best among the group, for human neutrophil studies. Indium-111, Tc-99m, and I-125 have been used as the tracers. Six bifunctional chelating agents (BFCAs) were evaluated in order to determine the most efficient agent for maximal cell labeling efficiency. Among these, the DTPA has given us the best results. (4) To botain maximum In-111 chelation and minimum loss of the MAb affinity, the optimal BFCA to MAb ratios for both IgG and IgM type of MAbs were determined. Four different substances, stannous chloride, ascorbic acid, sodium dithionite and sodium borohydride, were evaluated as reducing agents for Tc-99m reduction and its optimal binding to MAbs. Dithionite at the concentration of 200 ug/ml DTPA-MAb solution provides greater than 50% Tc-99m labeling efficiency and maintains its immunospecificity equal to that of In-111-DTPA-MAb. The ability of radiolabeled MAb to interact with blood cells selectively in whole blood and with isolated blood cells was assessed and compared

  14. Clinical validation of the avidin/indium-111 biotin approach for imaging infection/inflammation in orthopaedic patients

    International Nuclear Information System (INIS)

    Lazzeri, E.; Molea, N.; Bodei, L.; Bianchi, R.; Manca, M.; Marchetti, S.; Consoli, V.; Chinol, M.; Paganelli, G.; Mariani, G.

    1999-01-01

    We report here the results of a validation study of the avidin/indium-111 biotin approach in patients with skeletal lesions. This study involved 54 patients with orthopaedic conditions: 20 patients with intermediate suspected osteomyelitis of the trunk, 19 patients with infection/inflammation of prosthetic joint replacements, and 15 patients with suspected osteomyelitis of appendicular bones. Avidin (3 mg) was injected as an i.v. bolus, followed 4 h later by 111 In-biotin; imaging was acquired 30 min and 16-18 h after administration of 111 In-biotin. Technetium-99m hexamethylpropylene amine oxime ( 99m Tc-HMPAO)-labelled leucocyte scintigraphy was performed in 39/54 patients. The overall sensitivity of the avidin/ 111 In-biotin scan was 97.7% (versus 88.9% for 99m Tc-HMPAO leucocyte scintigraphy). While the diagnostic performance of avidin/ 111 In-biotin scintigraphy was similar to that of 99m Tc-HMPAO leucocyte scintigraphy in patients with prosthetic joint replacements or osteomyelitis of appendicular bones, the avidin/ 111 In-biotin approach clearly performed better than 99m Tc-HMPAO leucocyte scintigraphy in patients with suspected osteomyelitis of the trunk (100% sensitivity, specificity and accuracy versus 50% sensitivity, 100% specificity and 66.7% accuracy for 99m Tc-HMPAO-leucocyte scintigraphy). These results demonstrate the feasibility of the avidin/ 111 In-biotin approach for imaging sites of infection/inflammation in the clinical setting. Although no systematic advantages of avidin/ 111 In-biotin scintigraphy were found versus 99m Tc-HMPAO leucocyte scintigraphy, the newer scintigraphic method is more practicable and involves lower biological risk for the operators. (orig.)

  15. Experience with indium-111 and yttrium-90-labeled somatostatin analogs.

    Science.gov (United States)

    Virgolini, I; Traub, T; Novotny, C; Leimer, M; Füger, B; Li, S R; Patri, P; Pangerl, T; Angelberger, P; Raderer, M; Burggasser, G; Andreae, F; Kurtaran, A; Dudczak, R

    2002-01-01

    lung cancer ((99m)Tc-depreotide), indicating high diagnostic cabability of this type of receptor tracers. Consequently to their use as receptor imaging agents, hSSTR recognizing radioligands have also been implemented for experimental receptor-targeted radionuclide therapy. Beneficial results were reported for high-dose treatment with (111)In-DTPA-DPhe(1)-octreotide, based on the emission of Auger electrons. The Phase IIa study "MAURITIUS" (Multicenter Analysis of a Universal Receptor Imaging and Treatment Initiative, a eUropean Study) showed in progressive cancer patients (therapy entry criteria) with a calculated tumor dose > 10 Gy / GBq (90)Y-DOTA-lanreotide, the proof-of-principle for treating tumor patients with peptide receptor imaging agents. In the "MAURITIUS" study, cummulative treatment doses up to 200 mCi (90)Y-DOTA-lanreotide were given as short-term infusion. Overall treatment results in 70 patients indicated stable tumor disease in 35% of patients and regressive tumor disease in 10% of tumor patients with different tumor entities expressing hSSTR. No acute or chronic severe hematological toxicity, change in renal or liver function parameters due to (90)Y-DOTA-lanreotide treatment, were reported. (90)Y-DOTA-DPhe(1)-Tyr(3)-octreotide may show a higher tumor uptake in neuroendocrine tumor lesions and may therefore be superior for treatment in patients with neuroendocrine tumors. However, there is only limited excess to long-term and survival data at present. Potential indications for (90Y-DOTA-lanreotide are radioiodine-negative thyroid cancer, hepatocellular cancer and lung cancer. Besides newer approaches and recent developments of 188)Re-labeled radioligands, no clinical results on the treatment response are yet available. In conclusion, several radioligands have been implemented on the basis of peptide receptor recognition throughout the last decade. A plentitude of preclinical data and clinical studies confirm their potential use in diagnosis as well as

  16. False-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis

    International Nuclear Information System (INIS)

    Feldman, N.; Makler, P.T. Jr.; Alavi, A.

    1986-01-01

    A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with physical examination and laboratory findings failed to demonstrate evidence for osteomyelitis in a patient with a painful hip prosthesis, in whom images obtained with In-111-labeled leukocytes were positive. This observation demonstrated that the interpretation of the latter technique in demonstrating inflammation can cause a false impression of an infectious process

  17. Indium 111 scintigraphy in the exploration of the erythropoietic marrow (relative to 42 observations)

    International Nuclear Information System (INIS)

    Guerin, G.C.R.

    1976-01-01

    The bone marrow is difficult to explore as a whole because of its wide non-uniform distribution, variable with the hematopoietic and supporting tissue sites. 111 indium-transferrine bone marrow scintigraphy is a new technique which partly overcomes these difficulties and gives an idea of the overall distribution and richness of the erythropoietic marrow, thus showing up the erythropoiesis sites at a given moment. The properties of indium as medullary tracer are bound up with the characteristics of its metabolism which, to some extent at least resembles that of iron. The two main features are: - its fixation on transferrine (or siderophiline); - its binding to reticulocytes. Moreover indium 111 fulfils the physico-chemical criteria necessary for scintigraphic practice (long half-life, emission detectable by conventional scintigraphs, moderate irradiation of the patient). The properties of this radioelement and the technical conditions of use are examined in turn, then scintigraphic data are compared with the results of traditional bone marrow investigations: medullary biopsy and blood cell counts with reticulocyte fraction. This comparison concerns 42 scintigraphs carried out on patients suffering from various hematological diseases, with prospects of serious development in common [fr

  18. Yttrium-90 and indium-111 labelling, receptor binding and biodistribution of [DOTA0,d-Phe1,Tyr3[octreotide, a promising somatostatin analogue for radionuclide therapy

    International Nuclear Information System (INIS)

    Jong, M. de; Bakker, W.H.; Krenning, E.P.; Breeman, W.A.P.; Pluijm, M.E. van der; Bernard, B.F.; Visser, T.J.; Jermann, E.; Behe, M.; Powell, P.; Maecke, H.R.

    1997-01-01

    In vitro octreotide receptor binding of [ 111 In-DOTA 0 ,d-Phe 1 ,Tyr 3 [octreotide ( 111 In-DOTATOC) and the in vivo metabolism of 90 Y- or 111 In-labelled DOTATOC were investigated in rats in comparison with [ 111 In-DTPA 0 [octreotide [ 111 In-DTPAOC). 111 In-DOTATOC was found to have an affinity similar to octreotide itself for the octreotide receptor in rat cerebral cortex microsomes. Twenty-four hours after injection of 90 Y- or 111 In-labelled DOTATOC, uptake of radioactivity in the octreotide receptor-expressing tissues pancreas, pituitary, adrenals and tumour was a factor of 2-6 that after injection of 111 In-DTPAOC. Uptake of labelled DOTATOC in pituitary, pancreas, adrenals and tumour was almost completely blocked by pretreatment with 0.5 mg unlabelled octreotide, indicating specific binding to the octreotide receptors. These findings strongly indicate that 90 Y-DOTATOC is a promising radiopharmaceutical for radiotherapy and that 111 In-DOTATOC is of potential value for diagnosis of patients with octreotide receptor-positive lesions, such as most neuroendocrine tumours. (orig.). With 3 figs., 2 tabs

  19. 111Indium (DTPA-octreotide) scintigraphy in patients with cerebral gliomas

    International Nuclear Information System (INIS)

    Luyken, C.; Hildebrandt, G.; Klug, N.; Scheidhauer, K.; Schicha, H.; Krisch, B.

    1994-01-01

    Somatostatin receptors (SR) have been identified in vitro in normal brain tissue, in neuro-endocrine tumours and in cerebral gliomas WHO grade 1 or 2 by autoradiography or using somatostatin-gold conjugates. In vivo, SR detection has become possible by scintigraphy applying the somatostatin analogue octreotide, radio-labelled with 111 indium. It was supposed that expression of SR in cerebral gliomas corresponds to low grade tumour malignancy and that, in vivo, somatostatin receptor scintigraphy (SRS) could refine and improve the WHO grading system for cerebral gliomas. Nineteen patients with cerebral gliomas (grade 2: n=8, grade 3: n=3, grade 4: n=8) were examined with 111 In (DTPA-octreotide) to evaluate, whether SRS could improve the pre-operative estimation of tumour biology and the postoperative management. The results of SRS were related with the histological findings and with the in vitro demonstration of somatostatin-binding sites on cultured tumour cells incubated with a somatostatin-gold conjugate. In vivo, none of the patients with glioma grade 2 showed enhanced tracer uptake in the SRS, whereas in vitro SR were detected in cultured tumour tissue in 5 out of 5 cases. Every patient with glioma grade 3 or 4 demonstrated a high focal uptake of 111 In (DTPA-octreotide), as shown by SRS. Three patients with glioma grade 4, additionally examined with 99mTc-DTPA, showed an increased tracer uptake within the tumour area when compared with results of SRS. In vitro, SR were detected on tumour cell surface in 5 out of 6 tissue samples from patients with gliomas grade 3 or 4. One patient harbouring a cerebral abscess with a high focal tracer uptake in the SRS but with absence of somatostatin-binding sites in vitro. We conclude, that in glioma patients enhanced tracer uptake in receptor scintigraphy with 111 In (DTPA-octreotide) does not depend on the presence of SR in tumour but on the dysfunction of the blood-brain barrier. Thus, SRS dose not improve the

  20. Clinical validation of the avidin/indium-111 biotin approach for imaging infection/inflammation in orthopaedic patients

    Energy Technology Data Exchange (ETDEWEB)

    Lazzeri, E.; Molea, N.; Bodei, L.; Bianchi, R. [Regional Centre of Nuclear Medicine, University of Pisa, Pisa (Italy); Manca, M.; Marchetti, S.; Consoli, V. [Institute of Orthopedics, University of Pisa, Pisa (Italy); Chinol, M.; Paganelli, G. [Nuclear Medicine Service, European Institute of Oncology, Milan (Italy); Mariani, G. [Nuclear Medicine Service, DIMI, University of Genoa, Genoa (Italy)

    1999-06-01

    We report here the results of a validation study of the avidin/indium-111 biotin approach in patients with skeletal lesions. This study involved 54 patients with orthopaedic conditions: 20 patients with intermediate suspected osteomyelitis of the trunk, 19 patients with infection/inflammation of prosthetic joint replacements, and 15 patients with suspected osteomyelitis of appendicular bones. Avidin (3 mg) was injected as an i.v. bolus, followed 4 h later by {sup 111}In-biotin; imaging was acquired 30 min and 16-18 h after administration of {sup 111}In-biotin. Technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO)-labelled leucocyte scintigraphy was performed in 39/54 patients. The overall sensitivity of the avidin/{sup 111}In-biotin scan was 97.7% (versus 88.9% for {sup 99m}Tc-HMPAO leucocyte scintigraphy). While the diagnostic performance of avidin/{sup 111}In-biotin scintigraphy was similar to that of {sup 99m}Tc-HMPAO leucocyte scintigraphy in patients with prosthetic joint replacements or osteomyelitis of appendicular bones, the avidin/{sup 111}In-biotin approach clearly performed better than {sup 99m}Tc-HMPAO leucocyte scintigraphy in patients with suspected osteomyelitis of the trunk (100% sensitivity, specificity and accuracy versus 50% sensitivity, 100% specificity and 66.7% accuracy for {sup 99m}Tc-HMPAO-leucocyte scintigraphy). These results demonstrate the feasibility of the avidin/{sup 111}In-biotin approach for imaging sites of infection/inflammation in the clinical setting. Although no systematic advantages of avidin/{sup 111}In-biotin scintigraphy were found versus {sup 99m}Tc-HMPAO leucocyte scintigraphy, the newer scintigraphic method is more practicable and involves lower biological risk for the operators. (orig.) With 3 figs., 2 tabs., 56 refs.

  1. Platelet half-life in patients with primary hyperlipoproteinemia type IIa, IIb, and IV according to Fredrickson with and without clinical signs of atherosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Jaeger, E; Sinzinger, H; Widhalm, K; Kaliman, J; Hoefer, R [Vienna Univ. (Austria). 2. Medizinische Klinik; Ludwig Boltzmann-Institut fuer Nuklearmedizin, Vienna (Austria); Vienna Univ. (Austria). Kinderklinik; Vienna Univ. (Austria). Kardiologische Klinik)

    1982-09-01

    It is generally accepted that platelet half-life is shortened in atherosclerotic vascular diseases. Concerning changes due to hyperlipoproteinemia (HLP), however, there exist only few data. Therefore, we examined the platelet-half life in 60 patients with recently discovered HLP type IIa, IIb and IV according to Fredrickson before treatment in comparison to 60 controls. 33 of the HLP-patients had no clinical symptoms of angiopathy. 27 patients suffered from peripheral vascular disease or from coronary heart disease as verified by angiography. The labelling of autologous platelets was performed with 100..mu..Ci of /sup 111/Indium-oxine-sulfate at 37/sup 0/C for 5 minutes. The mean labelling efficiency was 90%, the recovery after 2 hours about 70%. Serum lipoproteins were estimated by means of ultracentrifugation and polyanionprecipitation according to Lipid Research Clinic Methods. In the patients with HLP platelet half-life was significantly shortened in comparison to the control group (p < 0.01). These changes were most pronounced in patients with HLP-type IIa and with atherosclerotic lesions, respectively. In patients with HLP-type IIa a very close correlation could be demonstrated between platelet half-life and LDL-cholesterol (r = -0.72; p < 0.001) as well as total cholesterol (r = -0.73; p < 0.001). These data prove that in HLP in-vivo platelet function as measured by platelet survival is significantly influenced even before the occurrence of clinically relevant symptoms of atherosclerosis.

  2. Discrimination between platelet-mediated and coagulation-mediated mechanisms in a model of complex thrombus formation in vivo

    International Nuclear Information System (INIS)

    Cadroy, Y.; Horbett, T.A.; Hanson, S.R.

    1989-01-01

    To study mechanisms of complex thrombus formation in vivo, and to compare the relative antithrombotic effects of anticoagulants and antiplatelet agents, a model was developed in baboons. Segments of collagen-coated tubing followed by two sequentially placed expansion chambers exhibiting disturbed flow patterns were exposed to native blood under laminar flow conditions. The device was incorporated for 1 hour into an exteriorized arteriovenous shunt in baboons under controlled blood flow (20 ml/min). Morphologic evaluation by scanning electron microscopy showed that thrombi associated with collagen were relatively rich in platelets but thrombi in the chambers were rich in fibrin and red cells. Deposition of indium 111-labeled platelets was continuously measured with a scintillation camera. Platelet deposition increased in a linear (collagen-coated segment) or exponential (chambers 1 and 2) fashion over time, with values after 40 minutes averaging 24.1 +/- 3.3 x 10(8) platelets (collagen segment), 16.7 +/- 3.4 x 10(8) platelets (chamber 1), and 8.4 +/- 2.4 x 10(8) platelets (chamber 2). Total fibrinogen deposition after 40 minutes was determined by using iodine 125-labeled baboon fibrinogen and averaged 0.58 +/- 0.14 mg in the collagen segment, 1.51 +/- 0.27 mg in chamber 1, and 0.95 +/- 0.25 mg in chamber 2. Plasma levels of beta-thromboglobulin (beta TG), platelet-factor 4 (PF4), and fibrinopeptide A (FPA) increased fourfold to fivefold after 60 minutes of blood exposure to the thrombotic device. Platelet deposition onto the collagen segment, chamber 1, and chamber 2 was linearly dependent on the circulating platelet count. Platelet accumulation in chamber 1 and chamber 2 was also dependent on the presence of the proximal collagen segment

  3. Indium-111 leukocyte localization in infected prosthetic graft

    Energy Technology Data Exchange (ETDEWEB)

    Purnell, G.L.; Walker, C.W.; Allison, J.W.; Dalrymple, G.V. (Univ. of Arkansas for Medical Sciences, Little Rock (USA))

    1990-08-01

    Infective endocarditis can be difficult to prove, even in the face of strong clinical suspicion. A case in which standard methods of diagnosis failed to demonstrate endocarditis in a patient with recurrent Staphylococcus aureus bacteremia and porcine aortic valve is reported. An In-111 labelled leukocyte SPECT study demonstrated uptake in the aortic root and leaflets, and autopsy demonstrated vegetations on the leaflets. In-111 may prove useful in demonstrating endocarditis in patients with prosthetic valve infection.

  4. Indium-111 leukocyte localization in infected prosthetic graft

    International Nuclear Information System (INIS)

    Purnell, G.L.; Walker, C.W.; Allison, J.W.; Dalrymple, G.V.

    1990-01-01

    Infective endocarditis can be difficult to prove, even in the face of strong clinical suspicion. A case in which standard methods of diagnosis failed to demonstrate endocarditis in a patient with recurrent Staphylococcus aureus bacteremia and porcine aortic valve is reported. An In-111 labelled leukocyte SPECT study demonstrated uptake in the aortic root and leaflets, and autopsy demonstrated vegetations on the leaflets. In-111 may prove useful in demonstrating endocarditis in patients with prosthetic valve infection

  5. Autologous 111In-oxine-labeled granulocytes in Yersinia infections

    International Nuclear Information System (INIS)

    Becker, W.; Boerner, W.; Fischbach, W.

    1985-01-01

    Autologous 111 In-oxine-labeled granulocytes have proved to be valuable for the localization of inflammatory bowel diseases, especially Crohn's disease and ulcerative colitis. Other rare inflammatory bowel diseases also yield positive 111 In scans. One case of Yersinia infection of the terminal ileum (Yersinia enterocolitica) showing an accumulation of 111 In-oxine-labeled granulocytes 0.5, 4, and 24 h after the reinjection of the labeled cells is described. The 4-day fecal excretion of 111 In-oxine granulocytes showed a slight inflammatory activity of the terminal ileum. One negative scan is reported in a cotrimoxazole-treated patient with Yersinia infection. (orig.)

  6. Interactive radiopharmaceutical facility between Yale Medical Center and Brookhaven National Laboratory. Progress report, November 1, 1980-October 31, 1981

    International Nuclear Information System (INIS)

    Gottschalk, A.

    Research conducted in three principal areas is discussed and summarized. (1) Investigation of the influence of antiarrhythmic agents, such as lidocaine and procainamide, on the chemotaxis and nylon fiber adherence of indium-111-labelled human polymorphonulcear leukocytes (PMNs) in vitro revealed that at normal therapeutic levels of lidocaine and procaine, the adherence and chemotactic function of In-111-PMNs remain unaltered. Results with higher therapeutic blood levels are also discussed. (2) An improved method for labeling human platelets with In-111-oxine is outlined, and the influence of centrifugal force, oxine, ethanol, and radiation on platelet function is reported. Results indicate that normal labeling procedures induce no gross changes in platelet function. (3) The chemical preparation of radioiodinated arachidonic acid (AA) and nonradioactive acid ester of AA, and the analysis of metabolites of these compounds following myocardial ischemia were investigated in dogs. The tissue uptake of 131 I-AA was compared to that of thallium-201

  7. Effects of altered platelet number on pulmonary hypertension and platelet sequestration in monocrotaline pyrrole-treated rats

    International Nuclear Information System (INIS)

    White, S.M.; Wagner, J.G.; Roth, R.A.

    1989-01-01

    To study the role of platelets in monocrotaline pyrrole (MCTP)-induced pulmonary hypertension, pulmonary sequestration of 111In-labeled platelets in rats treated with MCTP and anti-rat platelet serum (PAS) was examined. Lung injury from a single, intravenous injection of MCTP (3.5 mg/kg) at Day 8 was evident as elevated lung weight and lavage fluid protein and lactate dehydrogenase activity. Additionally, right ventricular hypertrophy and elevated pulmonary arterial pressures (PAP) occurred. Treatment with PAS on Days 6-8 did not affect the lung injury but resulted in an attenuation of the pulmonary hypertensive response. Pulmonary platelet sequestration was also decreased in PAS-treated rats, yet the sequestration in the lungs of MCTP-treated rats that received PAS was significantly higher than that in the lungs of N,N-dimethylformamide (DMF) controls. MCTP-treated rats receiving control serum (CS) tended to sequester more 111In-labeled platelets than respective DMF controls, but this was not statistically significant. Blood platelet half-life was unaltered in rats receiving CS. When rats were treated similarly with MCTP and PAS and were killed at 18 days, the attenuation of the pulmonary hypertensive response previously described was not observed, and lung injury was more extensive than when CS was given. Apparently, platelet depletion delayed the development of the pulmonary hypertensive response. Supranormal platelet numbers produced by splenectomy did not affect MCTP-induced lung injury or the elevation in PAP. These results support the hypothesis that the development of MCTP-induced pulmonary hypertension is mediated in part by platelets

  8. Cell labelling. Granule and platelet kinetics. Recent concepts

    International Nuclear Information System (INIS)

    Najean, Y.; Dresch, C.; Dassin, E.

    Some unsolved problems are reviewed concerning the lifetime of blood platelets, with special reference to excessive platelet consumption and its possible correction by anti-aggregation agents, in many vascular diseases. Regarding the production of platelets it is considered that the 75 Se-methionine labelling method alone offers a quantitative approach to the process and could be used for the physiological study of thrombopoietic factors. A short chapter is devoted to a survey of the points of agreement and disagreement regarding the lifetime of polynuclear cells and a tentative analysis of the reasons explaining the quite different results obtained with DFP and radiochromium labelling. Finally the methods used to study granule formation are criticized, though it is acknowledged that certain ideas useful in physiopathology have emerged from these different procedures [fr

  9. Measurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon-emission computed tomography, thallium-201, and indium 111-monoclonal antimyosin Fab

    International Nuclear Information System (INIS)

    Johnson, L.L.; Lerrick, K.S.; Coromilas, J.

    1987-01-01

    Single photon-emission tomography (SPECT) and indium 111-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous injection of labeled Fab fragments with the use of a dual-head SPECT camera with medium-energy collimators. Immediately after the first tomographic scan, thallium-201 was injected into nine of 12 dogs and imaging was repeated. Estimated infarct size in grams was calculated from transaxially reconstructed, normalized, and background-corrected indium SPECT images with the use of a threshold technique for edge detection. Estimated noninfarcted myocardium in grams was calculated from obliquely reconstructed thallium SPECT images by a similar method. The animals were killed and infarct size in grams and true infarct size as a percentage of total left ventricular myocardial volume were measured by triphenyl tetrazolium chloride staining. Estimated infarct size from indium SPECT images showed an excellent correlation with true infarct size (r = .95, SEE = 4.1 g). Estimated percentage myocardium infarcted was calculated by dividing estimated infarct size from indium images by the sum of estimated infarct size plus estimated noninfarcted myocardium obtained from thallium images. Correlation between the estimated percentage of myocardium infarcted and true percentage of myocardium infarcted was excellent

  10. /sup 99/Tcsup(m)-HMPAO labelled leucocytes: comparison with /sup 111/In-tropolonate labelled granulocytes

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M.; Roddie, M.E.; Zacharopoulos, G.P.; George, P.; Stuttle, A.W.J.; Lavender, J.P.; Danpure, H.J.; Osman, S.

    1988-06-01

    The lipophilic complex, /sup 99/Tcsup(m)-hexamethylpropyleneamine oxime (HMPAO) is an efficient leucocyte label, and labels granulocytes with more stability than mononuclear leucocytes. The recovery of /sup 99/Tcsup(m)-HMPAO granulocytes was similar to /sup 111/In-labelled granulocytes isolated and labelled in plasma using tropolone. The Tsub(1/2) of /sup 99/Tcsup(m)-HMPAO labelled granulocytes in blood was less than that of /sup 111/In-labelled granulocytes. The initial biodistribution of /sup 99/Tcsup(m)-labelled leucocytes was similar to /sup 111/In-labelled granulocytes, with a rapid initial lung transit, prominent splenic activity, bone marrow activity and minimal hepatic activity, although, unlike /sup 111/In, /sup 99/Tcsup(m) activity was also seen in urine, occasionally in the gallbladder, and, from about 4 h, consistently in the colon. Bone marrow activity was particularly prominent with /sup 99/Tcsup(m). About 6% of /sup 99/Tcsup(m) was excreted in the faeces up to 48 h after injection, and about 17% in urine up to 24 h. The time-activity curves of reticuloendothelial activity up to 24 h were broadly similar for the two labelled cell preparations. Clinical information given by the two agents was similar in 27 of 30 patients who received both. We conclude that with respect to granulocyte kinetics and clinical data, /sup 99/Tcsup(m)-HMPAO labelled leucocytes are comparable with /sup 111/In-tropolonate labelled granulocytes.

  11. The value of indium 111 leukocyte scanning in the evaluation of painful or infected total knee arthroplasties

    International Nuclear Information System (INIS)

    Rand, J.A.; Brown, M.L.

    1990-01-01

    Evaluation of painful total knee arthroplasties (TKAs) for infection can be difficult. Indium 111 ( 111 In) leukocyte bone scanning provides a minimally invasive technique for evaluation of possible infection. Thirty-eight patients with a painful TKA who had surgical exploration after 111 In leukocyte scanning were reviewed. The scan had an accuracy of 84%, a sensitivity of 83%, and a specificity of 85%. The 111 In leukocyte scans must be interpreted in conjunction with the clinical evaluation of the patient because they are less accurate for study of TKAs than of total hip arthroplasties

  12. Bone-marrow imaging with indium-111 chloride in aplastic anemia and myelofibrosis: concise communication

    International Nuclear Information System (INIS)

    Sayle, B.A.; Helmer, R.E.; Birdsong, B.A.; Balachandran, S.; Gardner, F.H.

    1982-01-01

    Twenty-nine patients with aplastic anemia and 11 patients with myelofibrosis were evaluated with indium-111 chloride bone-marrow imaging, ferrokinetics, and bone-marrow core biopsies. There was good correlation between the erythrocyte cellularity of the marrow and the In-111 bone-marrow scan grades in most patients. In some, the overall scan grade tended to underestimate the erythroid elements because the core biopsy had been taken from the area of the greatest radionuclide concentration on the scan. In patients with aplastic anemia, there was good correlation between the plasma iron clearance t1/2 and the scan grade. Less agreement was found in the comparison between the Fe-59 sacral and organ counts and the red-cell iron utilization. In patients with myelofibrosis, there was poor correlation between the surface counts over the sacrum and the red-cell iron utilization. Plasma iron clearances were abnormally short and were unrelated to the transferrin saturation levels. Eighteen patients were studied several times to evaluate their responses to steroid therapy. In all, there was good correlation between the bone-marrow imaging, the erythrocyte cellularity, ferrokinetics, and the patient's response to therapy. Indium-111 bone-marrow imaging is useful both in evaluating marrow erythroid activity and in following the response to therapy in patients with these diseases

  13. SPECT versus planar scintigraphy for quantification of splenic sequestration of 111In-labelled platelets

    International Nuclear Information System (INIS)

    Savolainen, S.; Helsinki Univ. Central Hospital

    1992-01-01

    The splenic uptake of thrombocytes and spleen size were studied in 25 patients with idiopathic thrombocytopenic purpura (ITP) using two methods: anterior/posterior scintigraphy and single photon emission computed tomography (SPECT). Various factors (acquisition and reconstruction protocols) influencing the quality of 111 In SPECT were studied. The splenic uptake, measured by SPECT, was found to be significantly higher in patients with a high level of autoantibodies in the blood than in patients without such antibodies. The correlation between the spleen SPECT volume and the geometric mean size calculated as geometric mean of anterior and posterior images differed by more than 50% from the SPECT volume in some patients. Based on these observations and on the results of phantom studies, it is concluded that a reasonable estimate of the spleen:liver uptake ratio may be obtained using planar imaging, but to estimate the spleen volume and the absolute splenic uptake of platelets SPECT imaging is needed, in spite of the present technical limitations of SPECT. (Author)

  14. Tracking of In-111-labeled human umbilical tissue-derived cells (hUTC) in a rat model of cerebral ischemia using SPECT imaging

    International Nuclear Information System (INIS)

    Arbab, Ali S; Chopp, Michael; Thiffault, Christine; Navia, Bradford; Victor, Stephen J; Hong, Klaudyne; Zhang, Li; Jiang, Quan; Varma, Nadimpalli RS; Iskander, ASM

    2012-01-01

    In order to increase understanding of how infused cells work, it becomes important to track their initial movement, localization, and engraftment efficiency following transplantation. However, the available in vivo cell tracking techniques are suboptimal. The study objective was to determine the biodistribution of intravenously administered Indium-111 (In-111) oxine labeled human umbilical tissue-derived cells (hUTC) in a rat model of transient middle cerebral occlusion (tMCAo) using single photon emission computed tomography (SPECT). Rats received 3 million In-111 labeled hUTC (i.v.) 48 hrs after tMCAo. Following the administration of either hUTC or equivalent dose of In-111-oxine (18.5 MBq), animals underwent SPECT imaging on days 0, 1, and 3. Radioactivity in various organs as well as in the stroke area and contralateral hemisphere was determined, decay corrected and normalized to the total (whole body including head) radioactivity on day 0. Immunohistochemical analysis was also performed to confirm the beneficial effects of hUTC on vascular and synaptic density, and apoptosis. Most of the radioactivity (43.36±23.07% on day 0) trafficked to the lungs immediately following IV administration of In-111 labeled hUTC (day 0) and decreased drastically to 8.81±7.75 and 4.01±4.52% on days 1 and 3 post-injection, respectively. In contrast, radioactivity measured in the lung of animals that received In-111-oxine alone remained relatively unchanged from day 0 to day 1 (18.38±5.45% at day 0 to 12.59±5.94%) and decreased to 8.34±4.25% on day 3. Significantly higher radioactivity was observed in stroke areas of animals that received In-111 labeled hUTC indicating the presence of cells at the site of injury representing approximately 1% of total administered dose. In addition, there was significant increase in vascular and synaptophysin immunoreactivity in stroke areas of rats that received In-111 labeled hUTC. The present studies showed the tracking of In-111 labeled h

  15. Platelet associated IgG, platelet mean life span and treatment with intravenous immunoglobulin in idiopathic thrombocytopenic purpura

    International Nuclear Information System (INIS)

    Nieminen, U.; Syrjaelae, M.; Ikkala, E.; Myllylae, G.

    1988-01-01

    The clinical significance of platelet associated IgG in ITP detected by direct platelet suspension immunofluorescence test (PSIFT) was studied. The platelet mean life span (MLS) was measured with 111 In-labelled platelets in 17 adult patients. All the patients had shortened platelet MLS. The direct PSIFT was positive in 14 patients. Patients were initially treated with prednisone; 12 patients with poor response to the drug were splenectomised. 8 of these 12 patients were treated with intravenous immunoglobulin (IvIg) before splenectomy. The response to IvIg was as good or better in the 3 patients with negative PSIFT, than in the 5 patients with positive PSIFT. (author)

  16. Interactive radiopharmaceutical facility between Yale Medical Center and Brookhaven National Laboratory. Progress report, June 1981-July 1982

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalk, A

    1982-01-01

    Progress is reported in the following research areas: (1) evaluation of /sup 14/C-labelled carboxyethyl ester 2-cardoxy methyl ester of arachidonic acid; (2) the effects of drug intervention on cardiac inflammatory response following experimental myocardial infarction using indium-111 labeled autologous leukoyctes; (3) the evaluation of /sup 97/Ru-oxine to label human platelets in autologous plasma; and (4) the specific in vitro radiolabeling of human neutrophils. (ACR)

  17. Effects of the Amino Acid Linkers on the Melanoma-Targeting and Pharmacokinetic Properties of Indium-111-labeled Lactam Bridge-Cyclized α-MSH Peptides

    Science.gov (United States)

    Guo, Haixun; Yang, Jianquan; Gallazzi, Fabio; Miao, Yubin

    2011-01-01

    The purpose of this study was to examine the profound effects of the amino acid linkers on the melanoma targeting and pharmacokinetic properties of novel 111In-labeled lactam bridge-cyclized DOTA-[X]-CycMSHhex {1,4,7,10-Tetraazacyclododecane-1,4,7,10-tetraacetic acid-[X]-c[Asp-His-dPhe-Arg-Trp-Lys]-CONH2, X=GlyGlyNle, GlyGluNle or NleGlyGlu} peptides. Methods Three novel DOTA-GGNle-CycMSHhex, DOTA-GENle-CycMSHhex and DOTA-NleGE-CycMSHhex peptides were designed and synthesized. The melanocortin-1 (MC1) receptor binding affinities of the peptides were determined in B16/F1 melanoma cells. The melanoma targeting and pharmacokinetic properties of 111In-DOTA-GGNle-CycMSHhex and 111In-DOTA-GENle-CycMSHhex were determined in B16/F1 melanoma-bearing C57 mice. Results DOTA-GGNle-CycMSHhex and DOTA-GENle-CycMSHhex displayed 2.1 and 11.5 nM MC1 receptor binding affinities, whereas DOTA-NleGE-CycMSHhex showed 873.4 nM MC1 receptor binding affinity. The introduction of the -GlyGly- linker maintained high melanoma uptake while decreased the renal and liver uptakes of 111In-DOTA-GlyGlyNle-CycMSHhex. The tumor uptake values of 111In-DOTA-GGNle-CycMSHhex were 19.05 ± 5.04 and 18.6 ± 3.56 % injected dose/gram (%ID/g) at 2 and 4 h post-injection. 111In-DOTA-GGNle-CycMSHhex exhibited 28, 32 and 42% less renal uptake values than 111In-DOTA-Nle-CycMSHhex we reported previously, and 61, 65 and 68% less liver uptake values than 111In-DOTA-Nle-CycMSHhex at 2, 4 and 24 h post-injection, respectively. Conclusion The amino acid linkers exhibited the profound effects on the melanoma targeting and pharmacokinetic properties of the 111In-labeled lactam bridge-cyclized α-MSH peptides. Introduction of the -GlyGly- linker maintained high melanoma uptake while reducing the renal and liver uptakes of 111In-DOTA-GlyGlyNle-CycMSHhex, highlighting its potential as an effective imaging probe for melanoma detection, as well as a therapeutic peptide for melanoma treatment when labeled with a therapeutic

  18. Detection of intracardiac thrombi by 111In-oxine platelet imaging

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Hayashi, Makoto; Hayashida, Kohei; Uehara, Toshiisa; Naito, Hiroaki; Kozuka, Takahiro; Boku, Eidai; Sakakibara, Hiroshi

    1985-01-01

    111 In-oxine platelet imaging (RI) was undertaken in 55 patients with suspected intracardiac thrombi. The results were compared with those from echocardiography (US) and computed tomography (CT). Sensitivity and specificity of RI were 71 % and 92 %, respectively. Visualizing thrombi on RI was seen in 10 (56 %) of 18 patients receiving anticoagulant therapy such as Warfarin (Group A) and in 12 (92 %) of 13 patients without it (Group B). This implied that active platelet deposition is inhibited by giving Warfarin. Regarding the size of thrombi, three methods showed the same size in 11 (85 %) of Group B. RI showed smaller thrombi than US and CT in 7 (39 %) of Group A, and failed to reveal them in 8 (44 %). Unlike morphological diagnosis by US and CT, RI proved to be of value in the evaluation of the activity of platelets (platelet deposition on the surface of thrombus). This method can also be used in the evaluation of thrombogenity. (Namekawa, K.)

  19. Measurement of acute Q-wave myocardial infarct size with single photon emission computed tomography imaging of indium-111 antimyosin.

    Science.gov (United States)

    Antunes, M L; Seldin, D W; Wall, R M; Johnson, L L

    1989-04-01

    Myocardial infarct size was measured by single photon emission computed tomography (SPECT) following injection of indium-111 antimyosin in 27 patients (18 male and 9 female; mean age 57.4 +/- 10.5 years, range 37 to 75) who had acute transmural myocardial infarction (MI). These 27 patients represent 27 of 35 (77%) consecutive patients with acute Q-wave infarctions who were injected with indium-111 antimyosin. In the remaining 8 patients either tracer uptake was too faint or the scans were technically inadequate to permit infarct sizing from SPECT reconstructions. In the 27 patients studied, infarct location by electrocardiogram was anterior in 15 and inferoposterior in 12. Nine patients had a history of prior infarction. Each patient received 2 mCi of indium-111 antimyosin followed by SPECT imaging 48 hours later. Infarct mass was determined from coronal slices using a threshold value obtained from a human torso/cardiac phantom. Infarct size ranged from 11 to 87 g mean 48.5 +/- 24). Anterior infarcts were significantly (p less than 0.01) larger (60 +/- 20 g) than inferoposterior infarcts (34 +/- 21 g). For patients without prior MI, there were significant inverse correlations between infarct size and ejection fraction (r = 0.71, p less than 0.01) and wall motion score (r = 0.58, p less than 0.01) obtained from predischarge gated blood pool scans. Peak creatine kinase-MB correlated significantly with infarct size for patients without either reperfusion or right ventricular infarction (r = 0.66). Seven patients without prior infarcts had additional simultaneous indium-111/thallium-201 SPECT studies using dual energy windows.(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Detection of cardiac transplant rejection with radiolabeled lymphocytes

    International Nuclear Information System (INIS)

    Bergmann, S.R.; Lerch, R.A.; Carlson, E.M.; Saffitz, J.E.; Sobel, B.E.

    1982-01-01

    To determine whether rejections of cardiac transplants could be detected specifically and non-invasively by lymphocytes labeled with indium-111 (111In), we studied 36 allogeneic and 14 isogeneic heterotopic cardiac transplants in rats. Allogeneic grafts accumulated autologous 111In-lymphocytes, detectable scintigraphically 24 hours after i.v. injection of the labeled cells. At the time of peak histologic rejection, the allogeneic grafts accumulated 92. +/- 4.8 times more activity than the native hearts (determined by well counting). The tissue-to-blood ratio in the rejecting transplants was 3.7 +/- 2.2; total uptake by the graft was 2.9 +/- 2.1% of the injected dose. Autoradiography confirmed that graft radioactivity was associated with labeled lymphocytes. In contrast, isogeneic grafts showed no signs of rejection and did not accumulate radioactivity. Because conventionally isolated and labeled lymphocytes are often contaminated with platelets, we prepared both 111In-platelets and purified 111In-lymphocytes for use in additional experiments. Allogeneic grafts accumulated platelets and purified lymphocytes independently. Thus, deposition of immunologically active cells in the rejecting graft representing specific pathophysiologic events can be detected. The results suggest that rejection of cardiac transplants can be detected noninvasively, potentially facilitating objective early clinical detection of rejection and titration of antirejection therapy

  1. Indium-111 leukocyte imaging in patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Uno, K.; Matsui, N.; Nohira, K.

    1986-01-01

    This study evaluates the usefulness of labeled leukocyte imaging in patients with rheumatoid arthritis. In 33 patients, the incidence of pain and swelling in 66 wrist joints and 66 knee joints was compared with the accumulation of [ 111 In]leukocytes. No accumulation of [ 111 In]leukocytes was seen in any of the patients' wrists (0/12) or knee joints (0/14) when both pain and swelling were absent. In contrast, 93% (25/27) of wrist joints and 80% (24/30) of knee joints with both pain and swelling were positive by [ 111 In]leukocyte scintigraphy. There was little correlation between the stage of the disease, as determined by radiography, and [ 111 In]leukocyte accumulation. This study suggests that [ 111 In]leukocyte imaging may be a reliable procedure for monitoring the activity of rheumatoid arthritis, especially for confirming the lack of an ongoing inflammatory response

  2. The relative role of neutrophils and platelets in the local accumulation of circulating lymphocytes at sites of ionophore A23187 inoculation

    Energy Technology Data Exchange (ETDEWEB)

    Hayes, J.M.; Simmons, R.L. (Univ. of Pittsburgh, PA (USA))

    1991-03-01

    The early cellular infiltrate at inflammatory sites consists predominantly of neutrophils and cells of the monocyte/macrophage lineage. The mechanism by which circulating, unsensitized lymphocytes accumulate at sites of inflammation is unknown. The pattern of accumulation of 111indium-labeled circulating thymocytes in response to local injections of the ionophore A23187 was studied and compared with the pattern of (125)iodinated albumin accumulation as a measure of vascular permeability. The kinetics of thymocyte accumulation differed from those of vascular permeability. Sublethal total-body irradiation (750 rads) markedly decreased thymocyte accumulation but had little effect on vascular permeability. Irradiation of the local site alone had no effect. T lymphocyte, T lymphoblast, and platelet accumulation generally followed the same pattern as thymocytes. Intravenous injection of neutrophils, but not platelets, partially restored lymphocyte accumulation in vivo in irradiated mice via a pathway involving the circulating neutrophil, and seemed to be independent of changes in vascular permeability.

  3. Indium-111 WBC detection of emphysematous gastritis in pancreatitis

    International Nuclear Information System (INIS)

    Caruana, V.; Swayne, L.C.; Salaki, J.S.

    1990-01-01

    We present a case of emphysematous gastritis initially detected with 111In oxine-labeled white blood cell scintigraphy and subsequently confirmed by computed tomography. Early aggressive antibiotic and supportive therapy resulted in a successful clinical outcome

  4. Autologous /sup 111/In-oxine-labeled granulocytes in Yersinia infections

    Energy Technology Data Exchange (ETDEWEB)

    Becker, W.; Boerner, W.; Fischbach, W.

    1985-04-01

    Autologous /sup 111/In-oxine-labeled granulocytes have proved to be valuable for the localization of inflammatory bowel diseases, especially Crohn's disease and ulcerative colitis. Other rare inflammatory bowel diseases also yield positive /sup 111/In scans. One case of Yersinia infection of the terminal ileum (Yersinia enterocolitica) showing an accumulation of /sup 111/In-oxine-labeled granulocytes 0.5, 4, and 24 h after the reinjection of the labeled cells is described. The 4-day fecal excretion of /sup 111/In-oxine granulocytes showed a slight inflammatory activity of the terminal ileum. One negative scan is reported in a cotrimoxazole-treated patient with Yersinia infection.

  5. Survival curves study of platelet labelling with 51Cr

    International Nuclear Information System (INIS)

    Penas, M.E.

    1981-01-01

    Platelet kinetics and idiopathic thrombocytopenic purpura were researched in the literature. An 'in vitro' platelet labelling with 51 Cr procedure in implementation has been evaluated in human beings. Functions used for fitting considered the cases whether the curve was linear or exponential as well as the presence of hematies. (author)

  6. A revised method of labeling mouse IgG with yttrium-90

    International Nuclear Information System (INIS)

    Arbab, A.S.; Koizumi, Kiyoshi; Araki, Tsutomu

    1996-01-01

    We report the successful labeling of mouse IgG with yttrium-90 (Y-90) using isothiocyanatobenzyl-ethylenediaminetetraacetic acid (SCN-Bz-EDTA) as a chelating agent and compared the result with labeling by indium-111 (In-111). After conjugating IgG with SCN-Bz-EDTA, a predetermined volume of conjugated IgG was mixed with different volumes of either Y-90 or In-111 acetate and incubated at 37degC. Labeling efficiency was assessed at specific intervals upto 3 hr. After 3 hr, the mixtures were challenged with Na 2 EDTA to evaluate the transchelation of labeled Y-90 or In-111. All mixtures showed labeling efficiency of around 50% with Y-90 and the leveling was fairly preserved even after Na 2 EDTA challenge. However, labeling with In-111 was unsuccessful when conjugated IgG was not separated from the unconjugated form. When separated, however, In-111 showed more than 80% labeling efficiency though labeling with In-111 could not tolerate Na 2 EDTA challenge. In conclusion IgG was efficiently labeled by Y-90 using SCN-Bz-EDTA though labeling with In-111 showed some problems associated with this method. (author)

  7. Indium labelled bleomycin (111In-BLM) as a tumor localizing agent

    International Nuclear Information System (INIS)

    Akisada, Masayoshi; Hayashi, Sanshin.

    1976-01-01

    Both fundamental and clinical studies of 111 In-BLM were performed. The in vivo stability of the complex was ascertained by thin-layer-chromatography of urine. The blood clearance, ratio of 111 In-BLM in plasma to that in whole blood, and cumulative excretion curves of urine and stool were studied. The blood clearance curve showed that the first half time was 16 minutes and that more than 90% of the administered activity was cleared from the circulating blood in two days. Ratios of plasma activity to the whole blood was almost constant 100 hours after injection. Urinary and fecal excretion showed that 80% of the administered activity was excreted in 24 hours, mainly in the urine (less than 1.0% in the feces). There appeared to be an inverse relationship between urinary and fecal excretion. The effective and biological half time of the liver, heart, bone marrow at the level of L 4 and spleen were obtained by counting the activity externally using probes located at each corresponding site. The activity in the bone marrow and heart had a rather short effective half time. The clinical usefulness of 111 In-BLM as a tumor imaging agent was evaluated in 19 patients, with 12 malignant and 7 benign lesions in Mitsui Memorial Hospital. Each study with 111 In-BLM was combined with 67 Ga-citrate scintigrams. A new method for comparative analyses of two radiopharmaceuticals without using a computer is reported here since comparative evaluation by the naked eye was difficult to make. Clinical experience to date seems to be encouraging to the detection of malignancy, although some benign tumors showed marked uptake of 111 In-BLM. (Evans, J.)

  8. Scintigraphy with In-111 labeled leukocytes

    International Nuclear Information System (INIS)

    Itoh, Kazuo; Tsukamoto, Eriko; Furudate, Masayori; Saito, Chihoko.

    1987-01-01

    With increasing necessity for In-111 labeled leukocyte scintigraphy (ILLS) as a routine examination, a problem of complicated labeling of leukocytes has arisen. In this study, simplified labeling of leukocytes was examined with respect to its ability to detect abscesses. Simplified labeling method yielded significantly satisfactory results for recovery and labeling rates of leukocytes, as compared with conventional recommended method. Therefore, ILLS by simplified technique was clinically applied in 58 patients with suppurative or non-suppurative diseases who gave informed consent. In an analysis of ILLS for detecting suppurative region, the sensitivity, specificity, and corrected specificity were found to be 81 %, 75 %, and 82 %, respectively. (Namekawa, K.)

  9. In-111 platelets used in evaluation of emboli and thrombi in patients with cerebrovascular accident

    International Nuclear Information System (INIS)

    Kuecuek, N.O.; Aras, G.; Ibis, E.; Soylu, A.; Tascilar, N.; Yuecemen, N.; Mutluer, N.

    2000-01-01

    Studies with In-111 platelets were conducted to evaluate pulmonary embolus, deep vein thrombus and cardiac thrombus. This study aimed to evaluate active thrombi and possible new emboli in patients with cerebrovascular accident (CVA) in the first 24 hours by using autologous In-111 platelets. Twenty-five patients were included in the study. Carotid artery thrombi observed in 10 patients with this technique were confirmed by Doppler ultrasonography. Intracranial thrombi appearing in 3 cases were verified by X-ray computed tomography (CT). Scintigraphy of 8 patients who showed findings suggesting CVA in CT revealed no abnormal accumulation. This was attributed to the possibility that they were small in size, deep in location and/or were also quite aged. Abnormal accumulations observed in the lungs of 3 patients and in the mediastinum and pelvis in one patient were verified by other radiological methods. In-111 platelet study was found to be useful in patients with CVA to evaluate the active thrombi and possible emboli in the early period before clinical symptoms appeared. (author)

  10. Chloro 111In tetraphenylporphyrin and its possible clinical application

    International Nuclear Information System (INIS)

    Cloutour, C.; Pommier, J.-C.; Ducassou, D.; Vuillemin, L.

    1982-01-01

    The synthesis of TPP 111 InCl is described taking into account an in vivo utilisation. This compound exhibits an in vitro good platelet labelling efficiency in pure plasma medium and without functional alteration of the cell physiology. The in vivo study shows a displacement of the tracer from the platelets to the erythrocytes and its recycling in the organism. (author)

  11. Alterations in an indium-111 Fab' under conditions of utilization

    International Nuclear Information System (INIS)

    Halpern, S.E.; Sudora, E.; Tarburton, J.P.; Hagar, P.

    1992-01-01

    This study was conducted to investigate alterations that occur in an indium/111 Fab' of a monoclonal antibody following its in vivo administration. Patients were infused with 111 In-Fab' of the monoclonal antibody ZCE-025. Serum and urine specimens were collected from these pateients. Starting materials, serum, urine and controls samples were studied by electrophoresis. Animal distribution studies were performed in normal Balb/c mice and, in some cases, nude mice bearing a carcinoembryonic antigen (CEA)/producing human colon tumour since the antibody targets CEA. The studies indicated that the molecule circulated almost totally intact for at least 4 h and to a considerable extent for 24 h, with some evidence for in vivo fragmentation by 24 h. Evidence was also obtained suggesting the formation of a high molecular weight species in some patients. Shortly after infusion, some of the 111 In in the urine appeared as the intact Fab', but within hours the majority migrated electro-phoretically as low molecular weight species. We conclude that while the majority of the 111 In-Fab' of this particular antibody remains intact and immunoreactive following its administration, the molecule is structurally changed to some degree shortly after its infusion into humans. Since each monoclonal antibody is unique, the degree and rapidity of degradation of its Fab' in vivo could vary markedly from the above and possibly adversely effect its utility as a radiopharmaceutical. (orig.)

  12. Bone marrow scintigraphy using 111Indium chloride in patients with aplastic anemia

    International Nuclear Information System (INIS)

    Mabuchi, Nobuhisa; Kumano, Machiko; Matsumoto, Fumiko; Arita, Shigehiro; Nakagawa, Kenichi; Fujii, Koichi; Yoshioka, Hiroyasu; Hamada, Tatsumi; Ishida, Osamu

    1987-01-01

    Bone marrow scintigraphy using 111 Indium chloride ( 111 In-chloride) was performed in 18 patients with aplastic anemia. The scintigrams were taken 48 hours after an intravenous injection of 111 In-chloride 3 mCi. The distribution patterns on scintigram were classified into 5 types: Type I (4 cases) showed no accumulation, Type II (6 cases) showed low accumulation in usual bone marrow sites. Type III (7 cases) showed island-like distribution in bone marrow sites. Type IV, although no case was included in the 18 patients, shows uneven distribution between pelvis and sternum or vertebrae. Type V (one case) showed almost normal accumulation in usual bone marrow sites. Bone marrow uptake of 111 In-chloride correlated well with the cellularity of bone marrow. There was a tendency for the cases of markedly increased saturated iron-binding capacity to show increased renal activity. In type III, both the percentage of cases who had been treated and the count of reticulocytes were higher than those in the other types, which suggested that island-like distribution on scintigram showed the regeneration responded to the therapy, and related to the erythropoietic function. (author)

  13. Radiolabeled platelets

    International Nuclear Information System (INIS)

    Datz, F.L.; Taylor, A.T.

    1986-01-01

    Initial interest in developing techniques to radiolabel platelets was spurred by the lack of an accurate method for measuring platelet life span in both normals and in thrombocytopenic patients. Early investigators could obtain only rough estimates of platelet life spans by monitoring the platelet counts of thrombocytopenic patients undergoing platelet transfusions. Labels were also sought that would allow imaging of platelets in vivo in order to better understand the pathophysiology of atherosclerosis, thrombophlebitis, and clotting disorders, and to improve the clinical diagnosis of these diseases. Two types of platelet labels were investigated: cohort (pulse) labels and random labels. Cohort labels are taken up by megakaryocytes in the bone marrow and incorporated in the DNA and other components of the forming platelet. In theory, only freshly released platelets of a uniform age are labeled. Random labels, on the other hand, tag platelets in the peripheral blood, labeling platelets of all ages

  14. The value of gamma camera and computed tomography data set coregistration to assess Lewis Y antigen targeting in small cell lung cancer by 111Indium-labeled humanized monoclonal antibody 3S193

    International Nuclear Information System (INIS)

    Quaia, Emilio; Krug, Lee M.; Pandit-Taskar, Neeta; Nagel, Andrew; Reuter, Victor E.; Humm, John; Divgi, Chaitanya

    2008-01-01

    Aim: To assess the value of data set coregistration of gamma camera and computed tomography (CT) in the assessment of targeting of humanized monoclonal antibody 3S193 labeled with indium-111 ( 111 In-hu3S193) to small cell lung cancer (SCLC). Methods and materials: Ten patients (6 male and 4 female; mean age ± S.D., 60 ± 4 years), from an overall population of 20 patients with SCLCs expressing Lewis Y antigen at immunohistochemical analysis, completed a four weekly injections of 111 In-hu3S193 and underwent gamma camera imaging. All had had, as part of their baseline evaluation, Fluorine18 fluoro-2-deoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT). Two readers in consensus retrospectively coregistered the gamma camera images with the CT component of the FDG PET/CT by automatic or manual alignment. The resulting image sets were visually examined and SCLC lesions targeting at coregistered gamma camera and CT was correlated side-by-side with the 18 F-FDG uptake. Results: A total number of 31 lesions from SCLC with a thoracic (n = 13) or extrathoracic location (n = 18) were all positive on FDG PET/CT. Coregistration of the gamma camera to the CT demonstrated targeting of antibody to all lesions >2 cm (n = 20) and in a few lesions ≤2 cm (n = 2), with no visualization of most lesions ≤2 cm (n = 9). No 111 In-hu3S193 uptake in normal tissues was observed. Conclusion: Coregistration of antibody gamma camera imaging to FDG PET/CT is feasible and allows valuable assessment of 111 In-hu3S193 antibody targeting to SCLC lesions >2 cm, while lesions ≤2 cm reveal a limited targeting

  15. Evaluation of the diagnostic efficacy of autologous 111In-labelled platelets as a scanning agent for deep vein thrombosis in the chacma baboon

    International Nuclear Information System (INIS)

    Dormehl, I.C.; Du Plessis, M.; Jacobs, D.J.; Pretorius, J.P.; Franz, R.C.

    1985-01-01

    The diagnostic efficiency of autologous sup(111I)n-labelled platelets (ILP) as a scanning agent in deep veinthrombosis (DVT) was investigated in 24 South African baboons (Papio ursinus). Thrombi were surgically induced by stasis, intimal injury and the injection of thrombin in the common femoral veins of adult baboons. The thrombi were allowed to age for 1, 2, 4, 8, 24, 48 and 72 h before injecting the ILP. Scanning was done with a large field gamma camera at 10 min post injection and again at 2, 4, 6, 8, 10, 14, 24, 48 and 72 h. Time-activity curves were thus obtained and it was possible to establish an optimal time after injection of the ILP to scan for each group of thrombi. The results indicate that only the younger thrombi (1-8 h after thrombus formation) were detected. Twenty-four hour and older thrombi were not visualised. A favourable time to scan in the case of the younger thrombi appeared to be approximately 20 h after the injection of ILP. However, the thrombus age limitation still impairs the diagnostic efficiency of the procedure. (orig.)

  16. Correlation between radioactivity and chemotherapeutics of the 111In-VNB-liposome in pharmacokinetics and biodistribution in rats

    Directory of Open Access Journals (Sweden)

    Tsai TH

    2012-02-01

    Full Text Available Wen-Chuan Lee1,*, Chih-Hsien Chang2,3,*, Chih-Min Huang1, Yu-Tse Wu1, Liang-Cheng Chen2, Chung-Li Ho2, Tsui-Jung Chang2, Te-Wei Lee2, Tung-Hu Tsai1,41Institute of Traditional Medicine, School of Medicine, National Yang-Ming University, Taipei, 2Division of Isotope Application, Institute of Nuclear Energy Research, Taoyuan, 3Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, 4Department of Education and Research, Taipei City Hospital, Taipei, Taiwan*These authors contributed equally to this workBackground: The combination of a radioisotope with a chemotherapeutic agent in a liposomal carrier (ie, Indium-111-labeled polyethylene glycol pegylated liposomal vinorelbine, [111In-VNB-liposome] has been reported to show better therapeutic efficiency in tumor growth suppression. Nevertheless, the challenge remains as to whether this therapeutic effect is attributable to the combination of a radioisotope with chemotherapeutics. The goal of this study was to investigate the pharmacokinetics, biodistribution, and correlation of Indium-111 radioactivity and vinorelbine concentration in the 111In-VNB-liposome.Methods: The VNB-liposome and 111In-VNB-liposome were administered to rats. Blood, liver, and spleen tissue were collected to determine the distribution profile of the 111In-VNB-liposome. A liquid chromatography tandem mass spectrometry system and gamma counter were used to analyze the concentration of vinorelbine and radioactivity of Indium-111.Results: High uptake of the 111In-VNB-liposome in the liver and spleen demonstrated the properties of a nanosized drug delivery system. Linear regression showed a good correlation (r = 0.97 between Indium-111 radioactivity and vinorelbine concentration in the plasma of rats administered the 111In-VNB-liposome.Conclusion: A significant positive correlation between the pharmacokinetics and biodistribution of 111Indium radioactivity and vinorelbine in blood, spleen

  17. Does the site of platelet sequestration predict the response to splenectomy in adult patients with immune thrombocytopenic purpura?

    Science.gov (United States)

    Navez, Julie; Hubert, Catherine; Gigot, Jean-François; Navez, Benoit; Lambert, Catherine; Jamar, François; Danse, Etienne; Lannoy, Valérie; Jabbour, Nicolas

    2015-01-01

    Splenectomy is the only potentially curative treatment for chronic immune thrombocytopenic purpura (ITP) in adults. However, one-third of the patients relapse without predictive factors identified. We evaluate the predictive value of the site of platelet sequestration on the response to splenectomy in patients with ITP. Eighty-two consecutive patients with ITP treated by splenectomy between 1992 and 2013 were retrospectively reviewed. Platelet sequestration site was studied by (111)Indium-oxinate-labeled platelets in 93% of patients. Response to splenectomy was defined at last follow-up as: complete response (CR) for platelet count (PC) ≥100 × 10(9)/L, response (R) for PC≥30 × 10(9)/L and splenectomy was performed in 81 patients (conversion rate of 16%), and open approach in one patient. Median follow-up was 57 months (range, 1-235). Platelet sequestration study was performed in 93% of patients: 50 patients (61%) exhibited splenic sequestration, 9 (11%) hepatic sequestration and 14 patients (17%) mixed sequestration. CR was obtained in 72% of patients, R in 25% and NR in 4% (two with splenic sequestration, one with hepatic sequestration). Preoperative PC, age at diagnosis, hepatic sequestration and male gender were significant for predicting CR in univariate analysis, but only age (HR = 1.025 by one-year increase, 95% CI [1.004-1.047], p = 0.020) and pre-operative PC (HR = 0.112 for > 100 versus splenectomy was independent of the site of platelet sequestration in patients with ITP. Pre-operative platelet sequestration study in these patients cannot be recommended.

  18. Deep venous thrombophlebitis: detection with 4-hour versus 24-hour platelet scintigraphy

    International Nuclear Information System (INIS)

    Seabold, J.E.; Conrad, G.R.; Ponto, J.A.; Kimball, D.A.; Frey, E.E.; Ahmed, F.; Coughlan, J.D.; Jensen, K.C.

    1987-01-01

    Thirty-one nonheparinized patients with suspected deep venous thrombophlebitis (DVT) underwent contrast venography and indium-111 platelet scintigraphy (In-111 PS). Venography permitted identification of acute DVT in 12 of 31 cases (39%). One additional patient was considered to have acute DVT despite nonconclusive venography results. In-111 PS results were positive at 4 hours in nine of 13 cases (69%) and at 24 hours in 12 of 13 cases (92%). Two of four patients with false-negative 4-hour In-111 PS studies had received warfarin. Thus, the sensitivity of 4-hour In-111 PS in patients not receiving anticoagulants was 82%. Venography results were negative for acute DVT in 18 cases, and 4-hour In-111 PS studies were negative or equivocal in each. In-111 PS is an alternative to contrast venography for detecting acute DVT. If 4-hour In-111 PS results are positive, anticoagulation can be initiated. Delayed images are necessary if the 4-hour images are negative or equivocal

  19. Radionuclide phlebography with sup(99m)Tc labelled autolog platelets

    International Nuclear Information System (INIS)

    Schroth, H.J.; Berberich, R.; Wilhelm, H.

    1982-01-01

    Platelets labelled with sup(99m)Tc-phytate are suitable for the detection of venous thrombosis. The accumulation of the platelets in the thrombotic area is dependent on the acuteness of the thrombotic process. In 30 patients we have combined with the injection a phlebography of the legs and the pelvis. The advantage of the method is mainly the better visuality of thrombotic areas in the veins of the pelvis. The exploration is without risque especially in patients which suffer from a hypersensibility of a contrast medium. The labelled platelets are injected in a superficial vein of the foot. Then a serial scintigraphy is performed with a #betta#-camera and a connected computer to judge the venous blood flow. With this method it is possible to visualize collateral systems and to dinstinguish between old and fresh thrombotic processes. (Author)

  20. Bone marrow scintigraphy using /sup 111/Indium chloride in patients with aplastic anemia

    Energy Technology Data Exchange (ETDEWEB)

    Mabuchi, Nobuhisa; Kumano, Machiko; Matsumoto, Fumiko; Arita, Shigehiro; Nakagawa, Kenichi; Fujii, Koichi; Yoshioka, Hiroyasu; Hamada, Tatsumi; Ishida, Osamu

    1987-12-01

    Bone marrow scintigraphy using /sup 111/Indium chloride (/sup 111/In-chloride) was performed in 18 patients with aplastic anemia. The scintigrams were taken 48 hours after an intravenous injection of /sup 111/In-chloride 3 mCi. The distribution patterns on scintigram were classified into 5 types: Type I (4 cases) showed no accumulation, Type II (6 cases) showed low accumulation in usual bone marrow sites. Type III (7 cases) showed island-like distribution in bone marrow sites. Type IV, although no case was included in the 18 patients, shows uneven distribution between pelvis and sternum or vertebrae. Type V (one case) showed almost normal accumulation in usual bone marrow sites. Bone marrow uptake of /sup 111/In-chloride correlated well with the cellularity of bone marrow. There was a tendency for the cases of markedly increased saturated iron-binding capacity to show increased renal activity. In type III, both the percentage of cases who had been treated and the count of reticulocytes were higher than those in the other types, which suggested that island-like distribution on scintigram showed the regeneration responded to the therapy, and related to the erythropoietic function.

  1. Comparative studies of 111In-labeled monoclonal antibody using spacer-containing and non-spacer bifunctional chelates. 2

    International Nuclear Information System (INIS)

    Sun, Baofu

    1994-01-01

    Indium-111-labeled A7 monoclonal antibodies using two spacer-containing chelates, succinimido-EGS-DTPA (EGS-DTPA: diester spacer) and maleimido-C10-Bz-EDTA (C10-Bz-EDTA: hydrocarbon spacer) were investigated in human LS180 colon tumor bearing nude mice and were compared with two non-spacer chelates, cyclic DTPA dianhydride (cDTPAA) and isothiocyanatobenzyl-EDTA (SCN-Bz-EDTA). Compared with immunoconjugates using non-spacer chelates, immunoconjugates using spacer-containing chelates, especially C10-Bz-EDTA-A7 showed lower 111 In activity in normal organs. The radioactivity in the liver for C10-Bz-EDTA-A7 decreased continuously till 96 hrs postinjection, however, this liver radioactivity for EGS-DTPA-A7 showed little change after 24 hrs. Moreover, in liver subcellular distribution study, EGS-DTPA-A7 showed a higher activity retention in mitochondrial fraction which contained lysosome, a place for metabolizing and storing of 111 In labeled antibody, than that of C10-Bz-EDTA-A7. The C10-Bz-EDTA-A7 conjugate demonstrated more preferable tumor-to-non tumor contrast on the scintigrams than that found with other three immunoconjugates. Up to 96 hrs postinjection, tumor bearing nude mice injecting with immunoconjugates using spacer-containing chelates exreted twice radioactivity from whole body than that excreted by using non-spacer chelates. Interestingly, different from other three chelates, C10-Bz-EDTA-A7 were mainly excreted via feces. We conclude that the decrease of radioactivity in normal tissues in the case of EGS-DTPA-A7 was due to the rapid decrease of activity in the blood, while in the case of C10-Bz-EDTA-A7 it was due to the quickly excreted small metabolite through faces. 111 In labeled C10-Bz-EDTA conjugate is superior, at least when conjugated with A7, to other three chelate conjugates used in this study. (author)

  2. Sequential use of indium-111 labeled monoclonal antibodies 96.5 and ZME-018 does not increase detection sensitivity for metastatic melanoma

    International Nuclear Information System (INIS)

    Frontiera, M.; Murray, J.L.; Lamki, L.

    1989-01-01

    Two indium-111 labeled anti-melanoma murine monoclonal antibodies (MAb), 96.5 and ZME-018, each recognizing separate antigens on melanoma cells, were administered intravenously to 17 patients with melanoma in a sequential fashion to determine whether: (1) additional tumor sites could be imaged with the combination compared to a single Mab; (2) the first MAb influenced the biodistribution and tumor localization of the second; and (3) significantly toxicity occurred with the combination. Patients were randomized to receive either 96.5, followed by ZME-018, ZME-018 followed by 96.5, or each MAb followed by itself (controls). Infusions of the second MAb occurred 10 days after the first infusion. Gamma camera images were obtained 72 hours after each antibody infusion. There were 139 known metastatic sites of which 72 lesions were localized by either MAb for an overall sensitivity of 52%. The detection rate was higher when lesions only greater than 1.5 cm were considered. Imaging results were independent of MAb administration sequence. When ZME-018 was given as the first infusion, when ZME-018 was given as a second infusion (p = NS). However, mean sensitivities using 96.5 as the first or second infusion were 48% and 66% respectively (p = NS). There was not a significant number of sites detected by MAb 2 that were missed by MAb 1. Human anti-murine antibody (HAMA) response occurred in seven of eight patients studied; two patients who experienced toxicity had levels of HAMA greater than 2000 ng/ml. We conclude that the use of these two murine anti-melanoma monoclonal antibodies given in sequential fashion did not significantly change the imaging sensitivity from that seen with each individual antibody

  3. Relative quantification of indium-111 pentetreotide and gallium-68 DOTATOC uptake in the thyroid gland and association with thyroid pathologies.

    Science.gov (United States)

    Lincke, Thomas; Singer, Joerg; Kluge, Regine; Sabri, Osama; Paschke, Ralf

    2009-04-01

    Recent data suggest that increased somatostatin receptor (SSTR) expression is detectable in several thyroid diseases. This raises the question as to the specificity and pathophysiologic relevance of these findings. Therefore, we systematically evaluated Indium-111 (In-111) pentetreotide scintigraphies and Gallium-68 (Ga-68) DOTA-Phe(1)-Tyr(3)-Octreotide (DOTATOC) positron emission tomography (PET) scans for thyroid radiotracer uptake. Relative binding of In-111 pentetreotide in the thyroid was measured by region of interest (ROI) technique in 4-hour and 24-hour post-injection (p.i.) planar images of 73 patients undergoing In-111 pentetreotide scintigraphy. Ga-68 DOTATOC PET scans of 77 patients were analyzed by ROI technique applied to coronal slices of 1 cm (0.39 inch) thickness with highest uptake in the thyroid region. A basal indium In-111 and Ga-68 DOTATOC uptake was found in normal thyroid glands. Hot nodules, disseminated thyroid autonomy, and most cases of active Hashimoto's disease as well as goiters and nodular thyroids showed increased In-111 pentetreotide and/or Ga-68 DOTATOC uptake. Higher relative In-111 pentetreotide uptake in the 24-hour p.i. images as compared to the 4-hour p.i. images except for patients after thyroidectomy indicates specific receptor binding in the thyroid. The increased In-111 pentetreotide and Ga-68 DOTATOC uptake in active Hashimoto's disease is most likely related to the lymphocytic infiltration of the thyroid. However, the physiologic or pathophysiologic relevance of the increased In-111 pentetreotide and Ga-68 DOTATOC uptake in normal thyroid glands, hot and cold nodules, and goiters and nodular thyroids remain to be determined.

  4. In vivo dissolution measurement with indium-111 summation peak ratios

    International Nuclear Information System (INIS)

    Jay, M.; Woodward, M.A.; Brouwer, K.R.

    1985-01-01

    Dissolution of [ 111 In]labeled tablets was measured in vivo in a totally noninvasive manner by using a modification of the perturbed angular correlation technique known as the summation peak ratio method. This method, which requires the incorporation of only 10-12 microCi into the dosage form, provided reliable dissolution data after oral administration of [ 111 In]lactose tablets. These results were supported by in vitro experiments which demonstrated that the dissolution rate as measured by the summation peak ratio method was in close agreement with the dissolution rate of salicylic acid in a [ 111 In]salicylic acid tablet. The method has the advantages of using only one detector, thereby avoiding the need for complex coincidence counting systems, requiring less radioactivity, and being potentially applicable to a gamma camera imaging system

  5. Reduction of renal uptake of 111In-DOTA-labeled and A700-labeled RAFT-RGD during integrin αvβ3 targeting using single photon emission computed tomography and optical imaging.

    Science.gov (United States)

    Briat, Arnaud; Wenk, Christiane H F; Ahmadi, Mitra; Claron, Michael; Boturyn, Didier; Josserand, Véronique; Dumy, Pascal; Fagret, Daniel; Coll, Jean-Luc; Ghezzi, Catherine; Sancey, Lucie; Vuillez, Jean-Philippe

    2012-06-01

    Integrin α(v)β(3) expression is upregulated during tumor growth and invasion in newly formed endothelial cells in tumor neovasculature and in some tumor cells. A tetrameric RGD-based peptide, regioselectively addressable functionalized template-(cyclo-[RGDfK])4 (RAFT-RGD), specifically targets integrin α(v)β(3) in vitro and in vivo. When labeled with indium-111, the RAFT-RGD is partially reabsorbed and trapped in the kidneys, limiting its use for further internal targeted radiotherapy and imaging investigations. We studied the effect of Gelofusine on RAFT-RGD renal retention in tumor-bearing mice. Mice were imaged using single photon emission computed tomography and optical imaging 1 and 24 h following tracer injection. Distribution of RAFT-RGD was further investigated by tissue removal and direct counting of the tracer. Kidney sections were analyzed by confocal microscopy. Gelofusine significantly induced a >50% reduction of the renal reabsorption of (111)In-DOTA-RAFT-RGD and A700-RAFT-RGD, without affecting tumor uptake. Injection of Gelofusine significantly reduced the renal retention of labeled RAFT-RGD, while increasing the tumor over healthy tissue ratio. These results will lead to the development of future therapeutic approaches. © 2012 Japanese Cancer Association.

  6. Platelet size does not correlate with platelet age.

    Science.gov (United States)

    Thompson, C B; Love, D G; Quinn, P G; Valeri, C R

    1983-08-01

    The relationship between platelet size and in vivo aging was investigated in the baboon using size-dependent platelet subpopulations separated by counterflow centrifugation. The separation characteristics, size, lactate dehydrogenase (LDH) activity, and dense-body content of the baboon platelet subpopulations were similar to those previously observed in studies of human platelets. Three independent labeling techniques were used: (1) in vivo labeling with 75Se-methionine, (2) in vitro labeling with 51Cr, and (3) in vivo labeling with 14C-serotonin. Maximal incorporation of all three labels showed a close correlation between the mean platelet volume (MPV) of each fraction and the platelet radioactivity. The onset of incorporation and rate of accumulation of 75Se-methionine were comparable in all fractions when corrected for differences in volume, suggesting that platelet size heterogeneity was present from the time of release of the platelets from the bone marrow. Survival studies using 51Cr and 14C-serotonin showed no translocation of the label from one fraction to another in the circulation over time. In vivo survival values for the three radionuclides showed a slight but significant correlation between the lifespan and the MPV of the fractions. The data suggest that large platelets were not younger platelets, but rather platelets with a longer life-span. Platelet size heterogeneity is the result of production factors in the bone marrow and not maturation in the circulation.

  7. Platelet size does not correlate with platelet age

    International Nuclear Information System (INIS)

    Thompson, C.B.; Love, D.G.; Quinn, P.G.; Valeri, C.R.

    1983-01-01

    The relationship between platelet size and in vivo aging was investigated in the baboon using size-dependent platelet subpopulations separated by counterflow centrifugation. The separation characteristics, size, lactate dehydrogenase (LDH) activity, and dense-body content of the baboon platelet subpopulations were similar to those previously observed in studies of human platelets. Three independent labeling techniques were used: (1) in vivo labeling with 75 Se-methionine, (2) in vitro labeling with 51 Cr, and (3) in vivo labeling with 14C-serotonin. Maximal incorporation of all three labels showed a close correlation between the mean platelet volume (MPV) of each fraction and the platelet radioactivity. The onset of incorporation and rate of accumulation of 75 Se-methionine were comparable in all fractions when corrected for differences in volume, suggesting that platelet size heterogeneity was present from the time of release of the platelets from the bone marrow. Survival studies using 51 Cr and 14 C-serotonin showed no translocation of the label from one fraction to another in the circulation over time. In vivo survival values for the three radionuclides showed a slight but significant correlation between the lifespan and the MPV of the fractions. The data suggest that large platelets were not younger platelets, but rather platelets with a longer life-span. Platelet size heterogeneity is the result of production factors in the bone marrow and not maturation in the circulation

  8. Preoperative and postoperative evaluation of vascular diseases by 111In-oxine platelet scintigraphy

    International Nuclear Information System (INIS)

    Nishibe, Toshiya; Hiraoka, Tomoya; Sakuma, Makoto; Sakai, Keisuke; Yasuda, Keishu; Tanabe, Tatsuzo; Nagao, Kazuhiko; Ito, Kazuo

    1991-01-01

    111 In-oxine platelet scintigraphy was performed on 20 patients with various vascular diseases to assess its clinical usefulness as a diagnostic procedure. Especially we evaluated its usefulness for thrombus formation after Ivaron sponge occlusion method (ISO method) and endotheliazation of prosthetic grafts. Negative image in thoracic false lumen was obtained 2 or 3 weeks after operation in all patients whose dissection was completely repaired by ISO method. It suggested early thromboexclusion in thoracic false lumen in which Ivalon sponge was implanted. Negative image was observed in two cases of saphenous vein graft and one of Dacron graft. The case of Dacron graft was examined 415 days after implantation. Negative result in this case would be accounted for by stabilized fibrin layer or good endothelial coverrage. The results suggest that 111 In-oxine platelet scintigraphy is an appropriate technique for evaluating the encapsulation of prosthetic grafts and thromboexclusion after ISO method. (author)

  9. Human platelet vasopressin receptor identification by direct ultraviolet photoaffinity labeling

    International Nuclear Information System (INIS)

    Thibonnier, M.

    1987-01-01

    Tritiated vasopressin ([ 3 H]AVP) was directly crosslinked to its human platelet receptor by using an ultraviolet irradiation procedure. After preincubation with [ 3 H]AVP, the hydrodynamic parameters of the hormone-receptor complexes solubilized with 3-[(3-cholamidopropyl)dimethylammonio]-1-propane sulfonate were derived from Sephacryl S-300 superfine gel filtration and from sucrose density gradient ultracentrifugation experiments. The following values were obtained: Stoke's radius = 5.48 +/- 0.1 nm, apparent sedimentation coefficient = 5.55 +/- 0.1 S, and calculated molecular weight = 132,000. On sodium dodecyl sulfate-8% polyacrylamide slab gel electrophoresis under reducing conditions, [ 3 H]AVP preferentially and specifically labeled a 125,000-dalton protein. The labeling of this protein was suppressed by addition of excess cold vasopressin, whereas angiotensin II did not inhibit incorporation of tritiated vasopressin in this protein. These results suggest that direct UV-photoaffinity labelling with [ 3 H]AVP is a suitable tool for the purification of the human platelet vasopressin receptor

  10. 111In-platelet and 125I-fibrinogen deposition in the lungs in experimental acute pancreatitis

    International Nuclear Information System (INIS)

    Goulbourne, I.A.; Watson, H.; Davies, G.C.

    1987-01-01

    An experimental model of acute pancreatitis in rats has been used to study intrapulmonary 125 I-fibrinogen and 111 In-platelet deposition. Pancreatitis caused a significant increase in wet lung weight compared to normal, and this could be abolished by heparin or aspirin pretreatment. 125 I-fibrinogen was deposited in the lungs of animals to a significantly greater degree than in controls (P less than 0.01). 125 I-fibrinogen deposition was reduced to control levels by pretreatment with aspirin or heparin (P less than 0.05). The uptake of radiolabeled platelets was greater in pancreatitis than in controls (P less than 0.001). Pancreatitis appears to be responsible for platelet entrapment in the lungs. Platelet uptake was reduced by heparin treatment but unaffected by aspirin therapy

  11. Elevated Lipoprotein(A Impairs Platelet Radiolabeling Yield

    Directory of Open Access Journals (Sweden)

    Susanne Granegger

    2015-02-01

    Full Text Available Objectives: Platelet radiolabeling in clinical routine usually results in labeling efficiencies (LE above 80%. A variety of risk factors and clinical conditions are known to impair platelet labeling yield, among them elevated triglycerides and low-density lipoproteins. The potential influence of lipoprotein(a (Lp(a, an atherogenic lipoprotein particle containing a kringle subunit, which is widely found in the proteins of fibrinolysis pathway, has never been studied. Normal Lp(a levels range below 30 mg/ dl. The exact prevalence of elevated Lp(a is unknown, most likely ranging below 10%. Even more rare is an isolated elevation despite an otherwise normal lipoprotein profile. Methods: We examined the role of isolated elevated Lp(a (> 50 mg/dl, ranging up to 440 mg/dl compared to patients with normal lipid profile. Platelets were radiolabeled with in-111-oxine at 37 °C for 5 minutes using ISORBE-consensus methodology. Results: The findings indicate that already at levels below 100 mg/dl Lp(a decreases LE. LE assessment after cross-incubation of hyper-Lp(a platelets with normal Lp(a plasma and vice versa reveals that platelets rather than the plasmatic environment are responsible for the deterioration of labeling yield. This behavior already has been reported for elevated low-density lipoproteins. Apparently, the quantitative influence of LDL and Lp(a/mg is comparable. Plotting the sum of LDL and Lp(a versus LE reveals a clear significant negative correlation. Conclusion: As extremely elevated Lp(a, particularly above 150 mg/dl, may significantly impair labeling results. We therefore recommend to include extremely elevated Lp(a into the list of parameters, which should be known before performing radiolabeling of human platelets.

  12. The search for an 111In labeled agent for the solid component of gastric emptying

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Brown, M.L.; Chowdhury, S.; Thomforde, G.; Malagelada, J.

    1988-01-01

    111 In-labeled solid meal was prepared by chelation of 111 In with Chelex resin bead. The effect of grinding of normal Chelex bead on 111 In chelation and retention in solid meal was evaluated in an in vitro system. The Chelex resin beads were ground in a mortar-pestle to form ground Chelex resin beads. Fine particles were removed by resuspension in distilled water and centrifugation. One hundred to 150 μCi of 111 In chloride was diluted with HCl and mixed with 1g of Chelex resin beads. Unbound 111 In was removed by centrifugation. The 111 In-labeled Chelex resin beads were mixed with fresh egg and 111 In-labeled solid metal was prepared by heating until solid. The meals were digested with HCl-pepsin for 4 h in a stirrer-bath (37 0 C). Aliquots were collected at intervals for determination of 111 In loss from 111 In-labeled solid meal. These results suggest that 111 In Chelex resin beads were retained in solid meals at a higher level than normal Chelex resin beads and other 111 In-tracers. (author)

  13. Search for an /sup 111/In labeled agent for the solid component of gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Dewanjee, M.K.; Brown, M.L.; Chowdhury, S.; Thomforde, G.; Malagelada, J.

    1988-01-01

    /sup 111/In-labeled solid meal was prepared by chelation of /sup 111/In with Chelex resin bead. The effect of grinding of normal Chelex bead on /sup 111/In chelation and retention in solid meal was evaluated in an in vitro system. The Chelex resin beads were ground in a mortar-pestle to form ground Chelex resin beads. Fine particles were removed by resuspension in distilled water and centrifugation. One hundred to 150 ..mu..Ci of /sup 111/In chloride was diluted with HCl and mixed with 1g of Chelex resin beads. Unbound /sup 111/In was removed by centrifugation. The /sup 111/In-labeled Chelex resin beads were mixed with fresh egg and /sup 111/In-labeled solid metal was prepared by heating until solid. The meals were digested with HCl-pepsin for 4 h in a stirrer-bath (37/sup 0/C). Aliquots were collected at intervals for determination of /sup 111/In loss from /sup 111/In-labeled solid meal. These results suggest that /sup 111/In Chelex resin beads were retained in solid meals at a higher level than normal Chelex resin beads and other /sup 111/In-tracers.

  14. Lymphocyte targeting with /sup 111/In-labelled monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Loutfi, I.; Batchelor, J.R.; Lavender, J.P.; Epenetos, A.A.

    1988-01-01

    In vitro tests were conducted using human T and B cell lines, as well as whole blood, to establish the usefulness of 2 murine monoclonal antibodies (MAbs), an anti-CD5 (Pan T) and a Pan B, for potential radioimmunolocalization and therapy. Both MAbs showed specificity for the cell line in question as tested by indirect immunofluorescence and radioimmunoassay. Assays carried out on whole blood showed 40-70% of the added activity of /sup 111/In-labelled Pan B antibody binding to B cells and 20-24% of /sup 111/In-Pan T antibody binding to T cells. The amount of internalised /sup 111/In-labelled Pan B was 6% of total amount at 24 hr indicating a slow internalization process. These results should allow for in vivo targeting of normal and neoplastic B and T cells.

  15. Evaluation of 111In leukocyte whole body scanning

    International Nuclear Information System (INIS)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-01-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with 111 In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes

  16. Platelet labelled radioisotope studies with Tc-99m-HM-PAO - own experience

    International Nuclear Information System (INIS)

    Dobkowski, P.; Krolicki, L.; Serafin-Krol, M.; Kielin, Z.; Staszkiewicz, W.

    1992-01-01

    The protocol of platelet labelling and results of 28 examinations with Tc- 99m labelled thrombocytes have been presented. In 6 cases this method was the only one, which allowed to show thrombotic lesions in carotid arteries. (author). 2 figs, 1 tab

  17. Development of a new radiolabel (lead-203) and new chelating agents for labeling monoclonal anntibodies for imaging

    International Nuclear Information System (INIS)

    Srivastava, S.C.; Mease, R.C.; Meinken, G.E.; Mausner, L.F.; Steplewski, Z.

    1988-01-01

    High liver uptake and slow body clearance presently limit the usefulness of 111 In labeled antibodies for tumor imaging. We have investigated 203 Pb as an alternate and better antibody label. The DTPA and cyclohexyl EDTA (CDTA) conjugates of an anticolon carcinoma antibody, 17-1A were labeled (bicyclic anhydride method) with 203 Pb and 111 In with 60 and 90% labeling yields, respectively. The biodistribution of 203 Pb-17-1A conjugates was compared with the corresponding 111 In-labeled preparations and with 203 Pb-DTPA, 203 Pb-nitrate and nonrelevant antibody controls in normal and human tumor (SW948) xenografted nude mice at 24, and 96 hr. Lead-203-labeled CDTA and DTPA antibody conjugates gave similar in vivo distributions. Even though the lead bound to these chelate-antibody conjugates was more labile in serum and in vivo, compared to indium, it cleared much faster from the liver and the whole body. A new series of chelating agents based on the incorporation of a trans-1,2- diaminocyclohexane moiety into the carbon backbone of polyaminocarboxylates is being synthesized. These are expected to provide stronger complexing ability for lead and produce greater in vivo stability. These ligands are also expected to be superior to EDTA and DTPA for labeling antibodies with other radiometals, including indium. 32 refs., 3 tabs

  18. In-111-oxine-labeled negative liposomes in tumor-bearing mice

    International Nuclear Information System (INIS)

    Chatal, J.F.; Guihard, D.; Bardy, A.; Pasqualini, R.

    1983-01-01

    The distribution of In-111-oxine-labelled liposomes in C 57 Bl 6 mice bearing a Lewis lung tumor and the variations contingent on modification of certain parameters have been studied. The distribution has been compared with that of Ga-67 citrate which is known for its affinity for lung tumors. In conclusion, it may be said that In-111-labeled negatively charged liposomes handled in oxygen-free conditions and having a size smaller than 80 nm make it possible to visualize a murine tumor as well, and even better, than does Ga-67 citrate

  19. Use of an anti-platelet monoclonal antibody F (ab')2 fragment for imaging thrombus

    International Nuclear Information System (INIS)

    Loutfi, I.; Stuttle, A.W.J.; Peters, A.M.; George, P.; Lavender, J.P.; Lumley, P.

    1990-01-01

    Ten patients with suspected thrombus have been studied using 111 In-labelled F (ab')2 fragments of P256, a monoclonal antibody which recognizes an epitope on the platelet membrane glycoprotein IIb/IIIa complex. The F (ab')2 fragment was radiolabelled with 111 In via diethylenetri-aminepentamacetic acid to give a specific activity of up to 190 MBq (5mCi) mg - 1 without impairment of immunoreactivity. In vitro platelet aggregation studies showed that the F (ab')2 fragment caused less platelet aggregation than the whole antibody on a molar ratio and was without significant effect upon the sensitivity of platelets to a range of aggregating agents. Platalets were labelled in ten patients by intravenous injection of approximately 100 μg P256 F (ab')2. Of the ten patients studies, six showed localization of activity consistent with platelet accumulation. Localization was clearly seen when associated with thrombus of the lower limbs (three patients: deep vein thrombosis; one patient: aortofemoral graft), and was apparent although less marked in two other cases, one of aortic aneurysm and one of carotid stenosis. Use of radiolabelled P256 F (ab')2 offers a means of non-invasive detection of thrombus which, from in vitro studies, would appear to have less direct effect of platelet behaviour than the whole antibody. (author). 9 refs. 8 figs. 1 tab

  20. 111In-oxine labelled leukocyte scintigraphy in the detection and localization of active inflammation and sepsis

    International Nuclear Information System (INIS)

    Kelly, M.J.; Kalff, V.; Hicks, R.J.; Spicer, W.J.; Spelman, D.W.

    1990-01-01

    Indium-111-oxine labelled leukocyte scintigraphy is a diagnostic technique which has recently become available for clinic evaluation within Australia. The technique was used to assess patients with suspected sepsis of inflammation after other commonly used investigations had failed to confirm a diagnosis. Four patient subgroups were evaluated: fever of unknown origin suspected abdominal or postoperative sepsis; suspected active inflammatory bowel disease; and suspected sepsis or inflammation of bones or joints. The course of all patients was followed for at least three months to establish the accuracy of the technique. The leukocyte labelling procedure took 90 min and imaging was carried out typically 3-6, 24 and occasionally 48 h after reinjection of the labelled leukocytes. Only in one patient labelling of leukocytes was unsuccessful. In the remaining 99 studies, the overall sensitivity of leukocyte scintigraphy was 88% (36 of 41 patients with a proved inflammatory or infective disease focus had positive scan findings);and the specificity was 95% (55 of 58 cases with no proved disease focus had normal scan findings). These results support the use of this method in nuclear medicine for the evaluation of suspected acute sepsis (symptoms less than four weeks' duration), of inflammatory bowel disease and of suspected infections involving appendicular bones which contain no active bone marrow. It is also a useful secondary scintigraphic procedure, after gallium-67-citrate scintigraphy, in patients with suspected infective disorders of more than four weeks' duration. 27 refs., 2 tabs., 5 figs

  1. Ultrasonography and indium 111 white blood cell scanning for the detection of intraabdominal abscesses

    International Nuclear Information System (INIS)

    Carroll, B.; Silverman, P.M.; Goodwin, D.A.; McDougall, I.R.

    1981-01-01

    Ultrasound and indium 111 white blood cell scanning were performed on 163 patients with suspected intraabdominal abscesses. In all but one case, intraabdominal abscesses were correctly identified by one or both tests; conversely, no patient was falsely diagnosed by both tests to have an abscess. Sonography was useful in those patients with focal symptoms, and frequently identified nonabscess causes for fever. White cell scanning was valuable when focal signs were absent, and frequently identified extraabdominal sources of sepsis. The two imaging modalities are complementary and provide a highly accurate and sensitive means of intraabdominal abscess detection

  2. In-111-labeled leukocyte scintigraphy in postoperative joint infection

    International Nuclear Information System (INIS)

    Ogawa, Yoji; Uetani, Masataka; Aziz, A.; Hayashi, Kuniaki

    2000-01-01

    To evaluate the role of In-111-labeled leukocyte scintigraphy in the patients with suspected postoperative joint infection, 41 scintigraphic examinations were performed in 24 patients. Scintigrams were interpreted by the degree of accumulation of labeled leukocytes, and were classified into 3 groups: positive, intermediate, and negative. In the cases of positive leukocyte scans, definite diagnosis of infection was made in all cases except one. In the cases of negative scans, there was no evidence of infection. In 13 cases, leukocyte scintigrams were interpreted in conjunction with bone scintigrams. Definite diagnosis of infection was made in all of the cases with positive combined leukocyte/bone scan, and there was no evidence of infection in cases with negative combined leukocyte/bone scan. This study demonstrates that In-111-labeled leukocyte scintigraphy is a useful method in diagnosis of postoperative joint infection, and accuracy of the examination improves when combined with bone scintigraphy. (author)

  3. 111In and 90Y labelled peptide radiopharmaceuticals for diagnosis and therapy

    International Nuclear Information System (INIS)

    Obenaus, E.; Crudo, J.L.; Castiglia, S.G. de

    2004-01-01

    Full text: The application of 111In-labelled octreotide to target somatostatin receptors on tumour cells has gained acceptance as a diagnostic procedure for demonstrating neuroendocrine and other SSTR-positive tumors. A further advance in the field of somatostatin analogues is the development of macrocyclic chelators that also bind beta particle emitters like 90Y and 177Lu. [90Y-DOTA, Tyr3] octreotide and [177Lu-DOTA, Tyr3] octreotate are currently being tried as the therapeutic agents. The aim of this work was to label two somatostatin analogues (Tyr3 Octreotide and Lanreotide) with 111In and 90Y using DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) as a chelating agent. DOTA in the form of the tri-t-butyl ester was coupled to the Lys5 (BOC) protected Tyr3octreotide and Lys5 (BOC) protected lanreotide in N,N-dimethylformamide, in a three-step reaction involving conjugation, using HATU and diisopropylethylamine as coupling reagents, de-protection with trifluoroacetic and HPLC purification of the conjugates. The DOTALAN and DOTATOC were labelled with 111In and 90Y and assayed by HPLC. In both cases solutions of gentisic acid in sodium acetate 0.4M pH=5.0 and conjugated peptides were added to the 111In or 90Y chloride. The final solution was heated at 90 deg. C for 25 minutes. We tried different amounts of the two peptide complexes per mCi of 111In/90Y and quality control of the labelled products was performed with the following HPLC system: reverse phase column, flow rate 1ml-min, UV/radiometric detection and a gradient solvent: solvent A: acetonitrile, solvent B: water TFA 0.1%, gradient: 0-3min 100% B, linear increase of eluent A to 50% from 3-13 min, 13-18 min 50% A, 18-20 min linear increase of eluent A to 70%. Serum stability was determined after 4 and 24 hr. incubation of the labeled peptide in human serum at 37 deg. C. After precipitation of proteins with acetonitrile the incubation mixture was analyzed by HPLC. Normal Wistar rats were

  4. In-111 platelet scintigraphy for detection of lower-extremity deep venous thrombophlebitis: Are 4-hour delayed images sufficient

    International Nuclear Information System (INIS)

    Seabold, J.E.; Conrad, G.R.; Ponto, J.A.; Kimball, D.A.; Frey, E.E.; Coughlan, J.D.; Ahmed, F.; Jensen, K.C.

    1986-01-01

    Twenty-one nonheparinized patients suspected of having lower-extremity deep venous thrombosis underwent 4- and 24-hour In-111-labeled platelet scintigraphy (PS) and lower-extremity contrast venography (CV). Eleven of the 21 patients (52%) had one or more intraluminal filling defects on CV, indicating active thrombophlebitis. In seven of these 11 patients (64%) In-PS was abnormal at 4 hours, and in ten (91%) at 24 hours. All patients with abnormal studies at 4 hours showed greater uptake of more abnormal sites at 24 hours. Of the ten patients with CV-negative studies, two had abnormal bilateral lower pelvis/upper thigh uptake in In-PS at 24 hours. These two In-PS studies were considered to be false positive. Twenty-four-hour In-PS images are necessary if 4-hour images show faint focal uptake of asymmetric blood pool activity, or are normal

  5. 21 CFR 111.410 - What requirements apply to packaging and labels?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What requirements apply to packaging and labels? 111.410 Section 111.410 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN MANUFACTURING...

  6. Platelet production, clearance and distribution in patients with idiopathic thrombocytopenic purpura

    International Nuclear Information System (INIS)

    Isaka, Yoshinari; Kambayashi, Junichi; Kimura, Kazufumi

    1990-01-01

    We have studied 8 normal subjects, and 12 patients with idiopathic thrombocytopenic purpura whose platelet counts ranged from 9x10 9 /L to 40x10 9 /L. Autologous platelets labeled with 111 In-tropolone were used for evaluation of mean platelet survival, platelet turnover, platelet sequestration sites, and platelet production (turnover) to clearance (sum of platelet uptake in the liver and the spleen) ratio. Platelet survival correlated directly with platelet counts. There was no significant correlation between the platelet sequestration pattern and platelet count, survival, or turnover. Sum of platelet uptake in the liver and the spleen showed a significant inverse correlation with platelet survival. No significant correlation was found between platelet turnover and platelet count. There was a significant correlation between the platelet production and clearance index when all subjects were analyzed. The distribution of platelet turnover showed considerable individual variation; eight of twelve patients showed platelet turnover less than mean minus 2SD of the control value, but others showed normal range. We conclude that although platelet destruction mechanism in RES shows a primary role of thrombocytopenia, impaired rate of effective thrombopoiesis may also contribute to disease severity in ITP. (author)

  7. Predictable efficacy for splenic artery embolization with sites of sequestration using 99mTc labeled platelets in immunogenic idiopathic thrombocytopenic purpura

    International Nuclear Information System (INIS)

    Tian Aiping

    1992-01-01

    28 patients with chronic Immunogenic (Idiopathic) Thrombocytopenic purpura (ITP) were determined of the site of sequestration using 99m Tc labeled platelets. Among them, partial splenic artery embolization were done in 20 patients. 7/8 spleen type cases and 1/6 hepato-spleen hepatic type cases have their platelets counts raised above 100 x 10 9 /L. The separation of platelets and its 99m Tc labelling method were also discussed. Above results suggested that the determination of sequestration site of the 99m Tc labelled platelets have some help for the splenic artery embolization therapy in ITP

  8. Pharmacokinetics of 111In-labeled anti-p97 monoclonal antibody in patients with metastatic malignant melanoma

    International Nuclear Information System (INIS)

    Rosenblum, M.G.; Murray, J.L.; Haynie, T.P.; Glenn, H.J.; Jahns, M.F.; Benjamin, R.S.; Frincke, J.M.; Carlo, D.J.; Hersh, E.M.

    1985-01-01

    Twenty-eight patients with metastatic malignant melanoma received anti-p97 murine monoclonal antibody (96.5) infused over 2 h at doses between 1 and 20 mg coupled to either 2.5 or 5.0 mCi of 111 In by the bifunctional chelating agent diethyltriaminepentaacetic acid. Clearance of 111 In from plasma closely fit an open, one-compartment mathematical model (r2 greater than 0.90). The overall half-life of 111 In plasma was approximately 31 h and did not appear to be dependent on the total dose of antibody administered. The apparent volume of distribution of the 111 In label approximated the total blood volume (7.8 +/- 0.7 liters) at the 1-mg dose and decreased to 3.0 +/- 0.14 liters at the 20-mg dose, suggesting saturation of antigenic or other extravascular binding sites at higher antibody doses. The clearance of the murine monoclonal antibody itself from plasma was measured by an enzyme-linked immunosorbent assay. The pharmacokinetics for the murine antibody in plasma also fit an open, one-compartment mathematical model. All pharmacokinetic parameters for unlabeled antibody closely paralleled those found for 111 In-labeled antibody pharmacokinetics. This suggests that the 111 In radiolabel remains complexed to the monoclonal antibody after in vivo administration. The cumulative urinary excretion of the 111 In label over 48 h was between 12 and 23% of the total administered dose and is assumed to represent 111 In-labeled chelate complex unattached to antibody. Analysis of the 111 In label in spleen, liver, heart, and kidney showed that the concentration of label in liver tissue was reduced with increasing antibody doses and coincided with changes in the apparent volume of distribution

  9. Immunoscintigraphy using 111In-DTPA labeled monoclonal antibodies: Comparison between ETC and planar imaging

    International Nuclear Information System (INIS)

    Happ, J.; Baum, R.P.; Frohn, J.; Weimer, B.; Hoer, G.; Halbsguth, A.; Lochner, B.; Brandhorst, I.

    1987-01-01

    The present study was done in order to examine if the use of 111 In-DTPA-labeled MAb fragments in place of 131 I-labeled MAb fragments increases the sensitivity of tomographic immunoscintigraphy to reach the level of that of planar imaging techniques. In 11 patients with various primary tumors, local recurrences or metastases [colorectal carcinoma (n=7), ovarian carcinoma (n=2), papillary thyroid carcinoma (n=1), undifferentiated carcinoma of the lung (n=1)], immuniscintigraphy (IS) was carried out using 111 In-DTPA-labeled F(ab') 2 fragments of various MAbs (anti-CEA, OC 125, anti-hTG) and planar and tomographic imaging were compared intraindividually. By conventional diagnostic procedures, the presence of a tumor mass was confirmed (transmission computer tomography, ultrasound) or verified ( 131 I whole-body scintigraphy, histology) in all cases. Immunoscintigraphy was positive in 9 out of 11 cases by ECT and in 10 out of 11 cases by planar imaging. When using 111 In-labeled MAb fragments, intraindividual comparison of ECT and planar imaging resulted in a similar sensitivity. The increased sensitivity of ECT using this tracer in contrast to 131 I-labeled MAb fragments may be attributed to the fact that the physical properties of 111 In are much more suitable for the gamma cameras most commonly used (single detector, 3/8'' crystal); using 111 In-labelled MAb fragments, count rates sufficient for ECT can be obtained within a reasonable acquisition time. This allows to combine IS with the advantages of ECT regarding tumour localization and prevention of artefacts due to superposition of background. (orig.) [de

  10. Evaluation of /sup 111/In leukocyte whole body scanning

    Energy Technology Data Exchange (ETDEWEB)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-11-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with /sup 111/In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes.

  11. Comparative study of two different Bombesin derivates labeled with 111In and biodistribution in normal mice

    International Nuclear Information System (INIS)

    Oliveira, Ricardo S.; Alcarde, Lais F.; Correa, Beatriz L.; Massicano, Adriana V.F.; Couto, Renata M.; Mengatti, Jair; Araujo, Elaine B. de

    2013-01-01

    Nuclear medicine is a medical speciality that uses radioactive compounds (radiopharmaceuticals), consisting of a substrate and a radioactive isotope, for diagnostic. Among the peptides of interest for Nuclear Medicine, bombesin (BBN), a 14 amino acid neuropeptide analog of human gastrin-releasing peptide, is one of the highlights. This is a comparative study aiming to establish the best condition to radiolabel two BBN derivatives, (DTPA-Phe-Gly 5 -BBN (6-14) ) and (DTPA-Phe-Gly 2 -BBN (6-14 )) with 111-indium. Specific objectives of this study were evaluate a good condition of radiolabelling in search excellent specific activity the bombesin derivatives and determinate the biodistribution in health mice model. Ten micrograms (10μg) of the derivative DTPA-Phe-Gly2-BBN (6-14) was labeled with 18.5 MBq (0.5 mCi) of 111 InCl 3 at 25°C for different times (5, 15 and 30 minutes). The best condition was applied to peptide mass variation (10, 5, 2.5, 1, 0.5, 0.25 and 0.1 μg), keeping all other parameters fixed. Finally, the influence of 111 InCl 3 activity in the radiolabeling process (18.5, 37, 55.5, 74, 185 MBq) was evaluated. The best conditions were repeated for the second derivate, DTPA-Phe-Gly 5 -BBN (6-14 ). The radiochemical purity was assessed by thin layer chromatography (TLC), using 0.2 M EDTA pH 5 as solvent, and high performance liquid chromatography (HPLC) with a C18 column with linear gradient 10% A to 90% A (v/v) (A: 0,1% of TFA in CH3CN; B: 0,1% of TFA in H2O) at a flow rate of 1 mL/minute for 15 minutes. Considering the reaction time, the higher radiochemical purity was obtained when 10μg of the peptide was labeled with 18.5 MBq (0.5 mCi) of 111 In for 15 minutes at 25°C (97.33 ± 0.50%, n=3). In the mass variation study, the best results of radiochemical purity were obtained when 10 μg of the peptide was employed (97.69 ± 0.4%, n = 4). Finally, the maximum specific activity of the radiolabelled peptides was 1.85 MBq/ μg. The maximum specific

  12. 99mTc-EDDA/HYNIC-TOC: a new 99mTc-labelled radiopharmaceutical for imaging somatostatin receptor-positive tumours; first clinical results and intra-patient comparison with 111In-labelled octreotide derivatives.

    Science.gov (United States)

    Decristoforo, C; Mather, S J; Cholewinski, W; Donnemiller, E; Riccabona, G; Moncayo, R

    2000-09-01

    [111In-diethylene triamine penta-acetic acid-D-Phe1]-octreotide (DTPA-octreotide) scintigraphy has gained widespread acceptance as a diagnostic clinical procedure in oncology for imaging somatostatin receptor-positive tumours. However, indium-111 as a radiolabel has several drawbacks, including limited availability, suboptimal gamma energy and high radiation burden to the patient. We have recently reported on the preclinical development of 99mTc-EDDA/HYNIC-TOC, a new octreotide derivative which showed promising results both in vitro and in vivo. We now report our initial clinical experiences with this new radiopharmaceutical in ten oncological patients. The clinical diagnoses were: carcinoid syndrome (n=5), thyroid cancer (n=3), pancreatic cancer (n=1) and pituitary tumour (n=1). The biodistribution and kinetics of 99mTc-EDDA/HYNIC-TOC were compared with those of 111In-DTPA-octreotide in six cases, and with those of 111In-DOTA-TOC in five cases. With the new tracer tumours were imaged within 15 min after injection and showed the highest target/non-target ratios 4 h after injection. Tumour uptake persisted up to 20 h p.i. The rate of blood clearance was similar to that of 111In-DTPA-octreotide but faster than that of 111In-DOTA-TOC, while urinary excretion was lower compared with the 111In derivatives. Semi-quantitative region of interest analysis showed that 99mTc-EDDA/HYNIC-TOC produced higher tumour/organ (target/non-target) ratios than the 111In derivatives, especially in relation to heart and muscle. Significantly more lesions could be detected in 99mTc images. We conclude that 99mTcEDDA/HYNIC-TOC shows better imaging properties for the identification of somatostatin receptor-positive tumour sites than currently available 111In-labelled octreotide derivatives.

  13. 99mTc-EDDA/HYNIC-TOC: a new 99mTc-labelled radiopharmaceutical for imaging somatostatin receptor-positive tumours: first clinical results and intra-patient comparison with 111In-labelled octreotide derivatives

    International Nuclear Information System (INIS)

    Decristoforo, C.; Cholewinski, W.; Donnemiller, E.; Riccabona, G.; Moncayo, R.

    2000-01-01

    [ 111 In-diethylene triamine penta-acetic acid-d-Phe 1 ]-octreotide (DTPA-octreotide) scintigraphy has gained widespread acceptance as a diagnostic clinical procedure in oncology for imaging somatostatin receptor-positive tumours. However, indium-111 as a radiolabel has several drawbacks, including limited availability, suboptimal gamma energy and high radiation burden to the patient. We have recently reported on the preclinical development of 99m Tc-EDDA/HYNIC-TOC, a new octreotide derivative which showed promising results both in vitro and in vivo. We now report our initial clinical experiences with this new radiopharmaceutical in ten oncological patients. The clinical diagnoses were: carcinoid syndrome (n=5), thyroid cancer (n=3), pancreatic cancer (n=1) and pituitary tumour (n=1). The biodistribution and kinetics of 99m Tc-EDDA/HYNIC-TOC were compared with those of 111 In-DTPA-octreotide in six cases, and with those of 111 In-DOTA-TOC in five cases. With the new tracer tumours were imaged within 15 min after injection and showed the highest target/non-target ratios 4 h after injection. Tumour uptake persisted up to 20 h p.i. The rate of blood clearance was similar to that of 111 In-DTPA-octreotide but faster than that of 111 In-DOTA-TOC, while urinary excretion was lower compared with the 111 In derivatives. Semi-quantitative region of interest analysis showed that 99m Tc-EDDA/HYNIC-TOC produced higher tumour/organ (target/non-target) ratios than the 111 In derivatives, especially in relation to heart and muscle. Significantly more lesions could be detected in 99m Tc images. We conclude that 99m Tc-EDDA/HYNIC-TOC shows better imaging properties for the identification of somatostatin receptor-positive tumour sites than currently available 111 In-labelled octreotide derivatives. (orig.)

  14. Radiochemical studies of the separation of some chloro-complexes of tin, antimony, cadmium and indium

    International Nuclear Information System (INIS)

    Ramamoorthy, N.; Mani, R.S.

    1976-01-01

    Radioisotopes of tin, antimony, cadmium and indium such as tin-113, antimony-124, antimony-125, cadmium-109, cadmium-115, indium-113m and indium-111 find extensive applications as tracers in various fields. These isotopes are produced by irradiation of targets in a reactor or a cyclotron. It is usually observed that in addition to the nuclear reactions giving rise to the desired isotopes, side reactions also take place giving rise to radionuclidic contaminants. Thus, antimony-125, indium-114m and indium-114 will be present in the cyclotron produced indium-111. The authors have studied column chromatography over hydrous zirconia for the separation of antimony from tin and indium, and cadmium from indium. These studies have thrown light on the role and behaviour of antimony-125 present as an impurity in tin-113 during the preparation of tin-113-indium-113m generators and have indicated methods for the preparation of 115 Cd-sup(115m)In generators and for separation of 111 In from proton irradiated cadmium targets. (Authors)

  15. Quantitative evaluation of endothelial cell attachment to vascular graft materials using In-111 Oxine label

    Energy Technology Data Exchange (ETDEWEB)

    Park, H.M.; Kesler, K.A.; Stinson, J.; Mock, B.; Arnold, M.

    1985-05-01

    Human umbilical vein endothelial cells were harvested, cultured and labeled with In-111 oxine using a modification of the technique described by Sharefkin et al. Average cell labeling efficiency was 42%. Two graft materials, polytetrafluoroethylene (Gortex) and polyester elastomer (Hytrel), with and without pretreatment with human fibronectin (FN) were incubated with the labeled cells. Quantitation of In-111 activity was done 3 times: at inoculation, after incubation (attachment) and after 1 hr of in vitro perfusion (retention). The average attachment ranged from 53% to 99.5%. The In-111 activity attached ranged from 10 to 20 ..mu..Ci per graft. A gamma camera with medium energy collimator and two pulse height analyzers for 173 and 247 keV photons with 20% window and an on-line computer was used. Images were obtained in 1.5 zoom mode. The count rate response to a In-111 point source up to 150 ..mu..Ci was linear. The results indicate Hytrel permits better endothelial cell attachment than Gortex and FN coating enhances the strength of attachment to both graft materials. The authors conclude that In-111 Oxine labeling is a reliable method for quantitatively evaluating endothelial cell attachment to vascular graft materials.

  16. The labeling of white blood cells with 99mTc and 111In complexes

    International Nuclear Information System (INIS)

    Hadizad, T.; Najafi, R.

    1993-01-01

    Leukocytes have been labelled with a variety of gamma emitters and labelled (mixed) leukocytes are used clinically to detect and localize sites of abscess in the abdominal area and inflammatory processes surrounding grafts, ulcerative colitis and study of leukocyte kinetics. In this project we used 99m Tc-Sn-Pyp, 99m Tc-Hexamethyl propenylamine oxine, 111 In-Tropolone and 111 In-Oxine Sulfate for the labelling of leukocytes. All the in vitro and in vivo tests have been done to get an optimum condition for injection

  17. Quantitative evaluation of indium-111 (In-111) octreotide pituitary activity: Comparison in patient with and without pituitary tumors

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, P.; Waxman, A.; Nguyen, K. [Cedars-Sinai Medical Center, Los Angeles, CA (United States)] [and others

    1995-05-01

    Indium 111 Octreotide is known to detect pituitary tumors. Variable low level pituitary activity has been reported in pts. with no demonstrable pituitary tumors. To our knowledge, there have been no studies which quantitatively categorize pituitary activity with respect to distinguishing normal subject from pts. with pituitary tumors. 13 pts. with proven, treated acromegaly were included, as well as 15 pts. with no history of pituitary disorder. Both groups underwent SPECT In-111 scintigraphy 24 hours post-injection Average count per pixel ratios were obtained for the pituitary/calvarium (P/C) and pituitary/brain (P/B) regions. 10 pts. with acromegaly underwent growth hormone (GH) measurements 2 hours post-glucose load. Statistical correlation between growth hormone levels using P/C and P/B ratios were obtained. P/C ratios, as well as P/B ratios demonstrated high correlation with serum GH levels correlation coefficient(r)= .717 for P/C p<0.05, and correlation coefficient(r) = 0.828 for P/B ratios p<0.005. P/C ratios and P/B ratios for controls correlated closely with the upper level of normal predicted by P/C or P/B ratios as a function of serum growth hormone found in patients with acromegaly. Somatostatin receptor SPECT scintigraphy of the pituitary and appropriate quantitation can predict patients with growth hormone secreting tumors.

  18. Determination of infarct size of acute myocardial infarction in dogs by magnetic resonance imaging and gadolinium-DTPA: Comparison with indium-111 antimyosin imaging

    International Nuclear Information System (INIS)

    Nishimura, T.; Yamada, Y.; Hayashi, M.; Kozuka, T.; Nakatani, T.; Noda, H.; Takano, H.

    1989-01-01

    Acute myocardial infarctions were produced in nine dogs by ligation of the left anterior descending coronary artery. Twenty-four hours after ligation, 0.5 mM/kg of gadolinium (Gd)-DTPA was injected intravenously, followed by cardiectomy 30 min later. Indium-111 antimyosin was administered intravenously 6 hr before cardiectomy to compare the infarct size with Gd-DTPA contrast enhancement. Areas of Gd-DTPA contrast enhancement were closely correlated with those of indium-111 antimyosin uptake (r = .86), although the former showed slightly greater than the latter. Partial and complete enhancements were observed in three and six dogs, respectively. In the T1 and T2 maps, T1 relaxation times of the infarcted area showed greater T1 shortening compared with normal myocardium, whereas T2 relaxation times were not different between infarcted and normal myocardium. Thus, Gd-DTPA showed significant contrast enhancement of the infarcted area because of greater T1 shortening and the extent of Gd-DTPA contrast enhancement expressed the infarct size precisely

  19. Homing pattern of indium-111 T-lymphocytes in normal and tumor bearing rats

    International Nuclear Information System (INIS)

    Kasi, L.P.; Glenn, H.J.; Mehta, K.; Teckemeyer, I.C.; Wong, W.; Haynie, T.P.

    1985-01-01

    T-lymphocytes play an important role in tumor immunology and possess cytotoxic capabilities. Purified T-lymphocytes were obtained by incubating mononuclear cells separated from peripheral blood of Fisher 344 rats in a nylon wool column at 37 0 C. The non-adherent T-lymphocytes which were eluted from the column had > 95% viability. About 1 x 10/sup 7/ purified T-lymphocytes were labeled with 30 μCi In-111 oxine (Labeling yield: 75 +-5%, viability >95%). The function of the labeled cells as estimated by their graft versus host reaction ability remained unaltered. To evaluate the distribution pattern, 1 x 10/sup 6/ In-111 T-lymphocytes (per 100g wt) were injected via tail vein in normal and in transplanted (right flank) solid hepatoma bearing Fisher 344 rats, and the percent uptake of activity of the total injected dose per organ and per gm tissue was estimated at 2, 24 and 48 hours post injection. In normal rats maximum uptakes were in the liver (24%-33%) with increasing uptakes in the spleen (6.8%-11%) and minimum uptakes in the kidneys, lungs, muscles, and blood from 2 to 48 hours after injection. The uptake pattern in tumor bearing rats were significantly different during the same time period: lower in the liver (17%-19%) and a decrease in the spleen (9%-0.4%). All other tissues displayed similar uptake patterns as in normal animals. Maximum tumor:muscle ratio (18.4) was found at 48 hours post injection. Further studies are indicated for the possible use of In-111 T-lymphocytes in T-lymphocyte disorders, inflammations, and as an additional tool in the diagnosis of tumors

  20. Chronic idiopathic thrombocytopenic purpura (ITP): site of platelet sequestration and results of splenectomy

    International Nuclear Information System (INIS)

    Gugliotta, L.; Guarini, A.; Motta, M.R.; Bachetti, G.; Tura, S.; Isacchi, G.; Ciccone, F.; Lattarini, C.; Mazzucconi, M.G.; Mandelli, F.; Baccarani, M.

    1981-01-01

    51 Cr-platelet kinetics study was performed in 197 patients with chronic ITP after corticosteroid therapy had failed to induce a long lasting remission. The incidence of splenic, spleno-hepatic, hepatic and diffuse platelet sequestration site was 58%, 17%, 6% and 19%, respectively. Splenic and spleno-hepatic sequestration sites were more frequent in patients less than 30 years old and in patients with a platelet count lower than 50 x 10 9 /l. 111 patients were splenectomized shortly after the study. Normalization of the platelet count was obtained more frequently in patients with splenic and spleno-hepatic sequestration than in the others. Labelled platelet sequestration site was the best predictor of the outcome of splenectomy. Platelet kinetics is a non-invasive investigation that should be performed early after the diagnosis of chronic ITP in all patients eligible for splenectomy. (author)

  1. High-throughput label-free detection of aggregate platelets with optofluidic time-stretch microscopy (Conference Presentation)

    Science.gov (United States)

    Jiang, Yiyue; Lei, Cheng; Yasumoto, Atsushi; Ito, Takuro; Guo, Baoshan; Kobayashi, Hirofumi; Ozeki, Yasuyuki; Yatomi, Yutaka; Goda, Keisuke

    2017-02-01

    According to WHO, approximately 10 million new cases of thrombotic disorders are diagnosed worldwide every year. In the U.S. and Europe, their related diseases kill more people than those from AIDS, prostate cancer, breast cancer and motor vehicle accidents combined. Although thrombotic disorders, especially arterial ones, mainly result from enhanced platelet aggregability in the vascular system, visual detection of platelet aggregates in vivo is not employed in clinical settings. Here we present a high-throughput label-free platelet aggregate detection method, aiming at the diagnosis and monitoring of thrombotic disorders in clinical settings. With optofluidic time-stretch microscopy with a spatial resolution of 780 nm and an ultrahigh linear scanning rate of 75 MHz, it is capable of detecting aggregated platelets in lysed blood which flows through a hydrodynamic-focusing microfluidic device at a high throughput of 10,000 particles/s. With digital image processing and statistical analysis, we are able to distinguish them from single platelets and other blood cells via morphological features. The detection results are compared with results of fluorescence-based detection (which is slow and inaccurate, but established). Our results indicate that the method holds promise for real-time, low-cost, label-free, and minimally invasive detection of platelet aggregates, which is potentially applicable to detection of platelet aggregates in vivo and to the diagnosis and monitoring of thrombotic disorders in clinical settings. This technique, if introduced clinically, may provide important clinical information in addition to that obtained by conventional techniques for thrombotic disorder diagnosis, including ex vivo platelet aggregation tests.

  2. Comparative study of two different Bombesin derivates labeled with {sup 111}In and biodistribution in normal mice

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Ricardo S.; Alcarde, Lais F.; Correa, Beatriz L.; Massicano, Adriana V.F.; Couto, Renata M.; Mengatti, Jair; Araujo, Elaine B. de, E-mail: ricardooliveira@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Nuclear medicine is a medical speciality that uses radioactive compounds (radiopharmaceuticals), consisting of a substrate and a radioactive isotope, for diagnostic. Among the peptides of interest for Nuclear Medicine, bombesin (BBN), a 14 amino acid neuropeptide analog of human gastrin-releasing peptide, is one of the highlights. This is a comparative study aiming to establish the best condition to radiolabel two BBN derivatives, (DTPA-Phe-Gly{sub 5}-BBN{sub (6-14)}) and (DTPA-Phe-Gly{sub 2}-BBN{sub (6-14})) with 111-indium. Specific objectives of this study were evaluate a good condition of radiolabelling in search excellent specific activity the bombesin derivatives and determinate the biodistribution in health mice model. Ten micrograms (10μg) of the derivative DTPA-Phe-Gly2-BBN (6-14) was labeled with 18.5 MBq (0.5 mCi) of {sup 111}InCl{sub 3} at 25°C for different times (5, 15 and 30 minutes). The best condition was applied to peptide mass variation (10, 5, 2.5, 1, 0.5, 0.25 and 0.1 μg), keeping all other parameters fixed. Finally, the influence of {sup 111}InCl{sub 3} activity in the radiolabeling process (18.5, 37, 55.5, 74, 185 MBq) was evaluated. The best conditions were repeated for the second derivate, DTPA-Phe-Gly{sub 5}-BBN{sub (6-14}). The radiochemical purity was assessed by thin layer chromatography (TLC), using 0.2 M EDTA pH 5 as solvent, and high performance liquid chromatography (HPLC) with a C18 column with linear gradient 10% A to 90% A (v/v) (A: 0,1% of TFA in CH3CN; B: 0,1% of TFA in H2O) at a flow rate of 1 mL/minute for 15 minutes. Considering the reaction time, the higher radiochemical purity was obtained when 10μg of the peptide was labeled with 18.5 MBq (0.5 mCi) of {sup 111}In for 15 minutes at 25°C (97.33 ± 0.50%, n=3). In the mass variation study, the best results of radiochemical purity were obtained when 10 μg of the peptide was employed (97.69 ± 0.4%, n = 4). Finally, the maximum specific activity of the radiolabelled

  3. Detection of acute inflammation with 111In-labeled nonspecific polyclonal IgG

    International Nuclear Information System (INIS)

    Fischman, A.J.; Rubin, R.H.; Khaw, B.A.

    1988-01-01

    The detection of focal sites of inflammation is an integral part of the clinical evaluation of the febrile patient. When anatomically distinct abscesses are present, lesion detection can be accomplished by standard radiographic techniques, particularly in patients with normal anatomy. At the phlegmon stage, however, and in patients who have undergone surgery, these techniques are considerably less effective. While radionuclide methods, such as Gallium-67 (67Ga)-citrate and Indium-111 (111In)-labeled WBCs have been relatively successful for the detection of early inflammation, neither approach is ideal. In the course of studies addressing the use of specific organism-directed antibodies for imaging experimental infections in animals, we observed that nonspecific polyclonal immunoglobulin G (IgG) localized as well as specific antibodies. Preliminary experiments suggested that the Fc portion of IgG is necessary for effective inflammation localization. Since polyclonal IgG in gram quantities has been safely used for therapy in patients with immune deficiency states, we decided to test whether milligram quantities of radiolabeled IgG could image focal sites of inflammation in humans. Thus far, we have studied a series of 84 patients with suspected lesions in the abdomen, pelvis, vascular grafts, lungs, or bones/joints. In 48 of 52 patients with focal lesions detected by surgery, computed tomography (CT), magnetic resonance imaging (MRI), or ultrasound (US), the IgG scan correctly localized the site, while 31 patients without focal inflammation had no abnormal focal localization of the radiopharmaceutical. Four patients had false negative scans and one patient had a false positive scan. For this small series, the overall sensitivity and specificity were 92% and 95%, respectively. In this report, we review our experience with this exciting new agent

  4. Mechanisms and kinetics for platelet and neutrophil localization in immune complex nephritis

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.J.; Alpers, C.E.; Pruchno, C.; Schulze, M.; Baker, P.J.; Pritzl, P.; Couser, W.G. (Univ. of Washington, Seattle (USA))

    1989-11-01

    We have previously reported that both neutrophils (PMNs) and platelets mediate proteinuria in a model of subendothelial immune complex (IC) nephritis (GN) in the rat. In order to understand the interaction of PMNs and platelets in this model, we quantitated the uptake of {sup 111}In-labelled platelets in glomeruli and correlated this with the number of PMNs observed histologically at 10 and 30 minutes, 1, 4 and 24 hours following induction of GN. Platelet accumulation was biphasic with a major peak at 10 minutes and a minor peak at four hours. Early platelet accumulation was complement dependent, and PMN-independent. PMN accumulation occurred after the initial platelet influx, peaking at one and four hours, was complement dependent, but was not affected by platelet depletion. Complement depletion significantly reduced proteinuria. This is the first documentation that platelet accumulation in glomeruli in IC GN is complement dependent. In addition, the enhancement of PMN-mediated injury by the platelet in this model does not involve effects of platelets on PMN localization, thus implying a functional interaction between these cells within the glomerulus.

  5. Breast cancer staqging using technitium-99m sestamibi and indium-111 pentetreotide single-photon emission tomography

    International Nuclear Information System (INIS)

    Chiti, A.; Agresti, R.; Maffioli, L.S.; Tomasic, G.; Savelli, G.; Crippa, F.; Pilotti, S.; Greco, M.; Bombardieri, E.

    1997-01-01

    We evaluated the clinical usefulness of single-photon emission tomography (SPET) with technetium-99m sestamibi and indium-111 pentetrotide in breast cancer staging. Fifteen patients with clinical and/or mammographic findings suggesting Tl-2N0-l breast cancer were studied. SPET images were acquired 20 min after 99m Tc-sestamibi injection and 4 and 24 h after 111 In-pentetreotide injection. Patients underwent surgery the day after the later 111 In-pentetrotide acquisition. Pathological examination showed 16 tumours in the 15 patients, with one bilateral carcinoma. The mean tumour diamter was 18.7 mm. Metastatic axillary involment was found in 6/16 tumours, with a mean of five metastatic nodes per axillary node involment. Both tracers correctly identified 15/16 primary tumours and five of the six cases of metastatic axillary node involvement. No difference between the tracers was observed in breast cancer staging. 99m Tc-sestamibi seems to the better tracer in terms of physical characteristics, execution time and cost-effectivness. Our data suggest the future possibility of using nuclear medicine imaging to avoid axillary dissection in patiens with Tl breast cancer

  6. Fragmentation, labeling and biodistribution studies of KS1/4, a monoclonal antibody

    International Nuclear Information System (INIS)

    Mohd, S.B.

    1987-01-01

    In this study, an IgG2a (KS1/4), a monoclonal antibody (MoAb) specific against a human lung adenocarcinoma (UCLA P-3) was successfully fragmented enzymatically to yield F(ab') 2 and Fab by using pepsin and papain, respectively. The kinetic of fragmentation of the MoAb was compared to that of human immunoglobulin G (IgG). A similar pattern of fragmentation was observed with both antibodies with a higher percentage yield of the F(ab') 2 and Fab obtained upon the fragmentation of the IgG by the enzymes. The KS1/4 and the two fragments were labeled with three different radionuclides, namely iodine-131, indium-111 and selenium-75. The radioiodination of the MoAb and the fragments was carried out by using a modified chloramine-T method. Radiometal labeling of the MoAb and the fragments with indium-111 was performed by using DTPA as a bifunctional chelating agent, while intrinsic labeling of the MoAb was done by culturing the hybridoma in the presence of 75 Se-methionine. The biodistribution of the radiolabeled MoAb, F(ab') 2 and Fab fragments were performed by injecting the preparations intravenously into nude mice bearing human lung adenocarcinoma

  7. PHARMACOKINETICS AND SCINTIGRAPHY OF INDIUM-111-DTPA-MOC-31 IN SMALL-CELL LUNG-CARCINOMA

    NARCIS (Netherlands)

    KOSTERINK, JGW; DEJONGE, MWA; SMIT, EF; PIERS, DA; KENGEN, RAM; POSTMUS, PE; SHOCHAT, D; GROEN, HJM; THE, HT; DELEIJ, L

    1995-01-01

    Radiolabeled MOC-31 retains its immunoreactivity and shows good in vivo immunolocalization to human SCLC xenografted in nude rats. Methods: We evaluated the immunotargeting properties and safety of In-111-labeled monoclonal antibody (MAb) MOC-31 (125 MBq, 5 mg) in six patients with histologically

  8. Improved endothelial cell seeding with cultured cells and fibronectin-coated grafts

    International Nuclear Information System (INIS)

    Seeger, J.M.; Klingman, N.

    1985-01-01

    A possible approach to the low seeding efficiency of endothelial cells into prosthetic grafts is to increase the number of cells to be seeded in cell culture and improve seeding efficiency by graft precoating with fibronectin. The effect of cell culture on cell adhesion is unknown, however, and fibronectin also binds fibrin, which may increase the thrombogenicity of the graft luminal surface. To investigate these questions, freshly harvested canine jugular vein endothelial cells from six animals and similar cells harvested from six primary and eight secondary cell cultures were labeled with 111 Indium and seeded into 5 cm, 4 mm PTFE grafts coated with fibronectin, using similar uncoated PTFE grafts as controls. Platelet accumulation and distribution on six similar coated and uncoated grafts placed in canine carotid, external jugular arterial venous shunts for 2 hr were also determined using autogenous 111 Indium-labeled platelets. Significant differences between group means were determined using the paired Student's t test. Results reveal that seeding efficiency is significantly better in all groups of coated grafts compared to uncoated grafts (P less than 0.01). Cells derived from cell culture also had significantly higher seeding efficiencies than freshly harvested cells when seeded into coated grafts (P less than 0.05) and tended to have higher seeding efficiencies than harvested cells when seeded into uncoated grafts (P = 0.53). Fibronectin coating increased mean platelet accumulation on the entire graft luminal surface, but not to a statistically significant degree (P greater than 0.1). Whether this increased seeding efficiency will improve graft endothelialization remains to be investigated

  9. Platelet size and age determine platelet function independently

    International Nuclear Information System (INIS)

    Thompson, C.B.; Jakubowski, J.A.; Quinn, P.G.; Deykin, D.; Valeri, C.R.

    1984-01-01

    A study was undertaken to examine the interaction of platelet size and age in determining in vitro platelet function. Baboon megakaryocytes were labeled in vivo by the injection of 75Se-methionine. Blood was collected when the label was predominantly associated with younger platelets (day 2) and with older platelets (day 9). Size-dependent platelet subpopulations were prepared on both days by counterflow centrifugation. The reactivity of each platelet subpopulation was determined on both days by measuring thrombin-induced aggregation. Platelets were fixed after partial aggregation had occurred by the addition of EDTA/formalin. After removal of the aggregated platelets by differential centrifugation, the supernatant medium was assayed for remaining platelets and 75Se radioactivity. Comparing day 2 and day 9, no significant difference was seen in the rate of aggregation of a given subpopulation. However, aggregation was more rapid in the larger platelet fractions than in the smaller ones on both days. A greater percentage of the 75Se radioactivity appeared in the platelet aggregates on day 2 than on day 9. This effect was independent of platelet size, as it occurred to a similar extent in the unfractionated platelets and in each of the size-dependent platelet subpopulations. The data indicate that young platelets are more active than older platelets. This study demonstrates that size and age are both determinants of platelet function, but by independent mechanisms

  10. Comparison of indium-111 octreotide and thalium-201 scintigraphy in patients mammographically suspected of having breast cancer: preliminary results

    International Nuclear Information System (INIS)

    Vural, G.; Uenlue, M.; Atasever, T.; Oezur, I.; Oezdemir, A.; Goekcora, N.

    1997-01-01

    Indium-111 octreotide and thallium-201 scintigraphic studies were compared in 21 patients (16 with palpable and five with non-palpable lesions) suspected of having breast malignancies on the basis of mammography. Early (15 min) and late (3 h) 201 Tl (111 MBq) and 4-h and 24-h 111 In-octreotide (111-148 MBq) static planar anterior images (matrix 256 x 256) were obtained on separate days. Images were evaluated both visually and quantitatively. Biopsy was performed following the imaging studies. Histopathology revealed 17 breast carcinomas (15 cases of invasive ductal carcinoma, one mucinous adenocarcinoma and one intraductal carcinoma) and four benign breast lesions (two fibroadenomas, one abscess and one case of fat necrosis). The means histopathological tumour size (mean largest diameter) was 3.38±1.9 cm. 111 In-octreotide detected 16 of the 17 breast cancers (94%) while 201 Tl detected 13 of them (76%). Both 111 In-octreotide and 201 Tl missed one nonpalpable carcinoma showing only an isolated cluster of microcalcifications on mammography. The smallest tumour size detected by both agents 1.5 x 1.5 cm. Of the four benign lesions, only the breast abscess revealed both 201 Tl and 111 In-octreotide uptake. 111 In-octreotide scan also showed tracer uptake in five of the six patients with histologically proven axiallary metastases, while four of these six patient showed 201 Tl uptake. (orig./VHE)

  11. Comparison of indium-111 octreotide and thalium-201 scintigraphy in patients mammographically suspected of having breast cancer: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Vural, G. [Dept. of Nuclear Medicine, Faculty of Medicine, Gazi Univ., Ankara (Turkey); Uenlue, M. [Dept. of Nuclear Medicine, Faculty of Medicine, Gazi Univ., Ankara (Turkey); Atasever, T. [Dept. of Nuclear Medicine, Faculty of Medicine, Gazi Univ., Ankara (Turkey); Oezur, I. [Dept. of Radiology, Faculty of Medicine, Gazi Univ., Ankara (Turkey); Oezdemir, A. [Dept. of Radiology, Faculty of Medicine, Gazi Univ., Ankara (Turkey); Goekcora, N. [Dept. of Nuclear Medicine, Faculty of Medicine, Gazi Univ., Ankara (Turkey)

    1997-03-01

    Indium-111 octreotide and thallium-201 scintigraphic studies were compared in 21 patients (16 with palpable and five with non-palpable lesions) suspected of having breast malignancies on the basis of mammography. Early (15 min) and late (3 h) {sup 201}Tl (111 MBq) and 4-h and 24-h {sup 111}In-octreotide (111-148 MBq) static planar anterior images (matrix 256 x 256) were obtained on separate days. Images were evaluated both visually and quantitatively. Biopsy was performed following the imaging studies. Histopathology revealed 17 breast carcinomas (15 cases of invasive ductal carcinoma, one mucinous adenocarcinoma and one intraductal carcinoma) and four benign breast lesions (two fibroadenomas, one abscess and one case of fat necrosis). The means histopathological tumour size (mean largest diameter) was 3.38{+-}1.9 cm. {sup 111}In-octreotide detected 16 of the 17 breast cancers (94%) while {sup 201}Tl detected 13 of them (76%). Both {sup 111}In-octreotide and {sup 201}Tl missed one nonpalpable carcinoma showing only an isolated cluster of microcalcifications on mammography. The smallest tumour size detected by both agents 1.5 x 1.5 cm. Of the four benign lesions, only the breast abscess revealed both {sup 201}Tl and {sup 111}In-octreotide uptake. {sup 111}In-octreotide scan also showed tracer uptake in five of the six patients with histologically proven axiallary metastases, while four of these six patient showed {sup 201}Tl uptake. (orig./VHE)

  12. Radioimmunoimaging in malignant melanoma with 111In-labeled monoclonal antibody 96.5

    International Nuclear Information System (INIS)

    Murray, J.L.; Rosenblum, M.G.; Sobol, R.E.

    1985-01-01

    A radiolabeled monoclonal antibody (96.5) reactive with an Mr 97,000 antigen found on over 80% of melanoma cell lines and tissue extracts was examined for its ability to detect malignant melanoma metastases in vivo. For imaging purposes, it was conjugated with diethyltriaminepentaacetic acid and subsequently labeled with 111 In by chelation. Thirty-one patients with metastatic melanoma received single injections of monoclonal antibody 96.5 at concentrations ranging from 0.5 to 20 mg and at specific activities of 111 In ranging from 0.125 to 4 mCi/mg. Total-body scans were performed at various time intervals following administration. No serious side effects were observed. Of a total of 100 previously documented metastatic sites, 50 imaged for a specificity of 50%. The number of sites imaged increased significantly as the amount of antibody administered increased relative to the average radiation dose. Considerable background uptake of isotope was observed in blood pool and other organs with gradual acquisition of label in tumor sites by 48 to 72 h. Hence, tumor imaging of melanoma using 111 In-labeled monoclonal antibody 96.5 appeared feasible, especially at antibody doses above 2 mg

  13. Influence of the particle size of activated charcoal on labeling efficiency with 67Ga-citrate for colonic transit study

    International Nuclear Information System (INIS)

    Wan-Yu Lin; Shih-Chuan Tsai; Kai-Yuan Cheng; Bor-Tsung Hsieh

    2008-01-01

    Indium-111 and 99m Tc have been proposed for colonic transit study, but 111 In is expensive and the half-life of 99m Tc is too short for the study. Gallium-67 citrate is inexpensive and has a suitable half-life. In our previous study, we successfully labeled 67 Ga-citrate activated charcoal, and the labeling efficiency exceeded 91% after a 96 hour incubation period. In this work, we evaluated the influence of the size of activated charcoal particles on the labeling efficiency with 67 Ga-citrate. The data showed that the influence of particle size on the labeling efficiency of activated charcoal with 67 Ga was insignificant. Both sizes of activated charcoal particles can be used for labeling with 67 Ga in colonic transit study. (author)

  14. Comparison of simultaneous 99mTc-HMPAO and 111In oxine labelled white cell scans in the assessment of inflammatory bowel disease

    International Nuclear Information System (INIS)

    Allan, R.A.; Bassingham, S.; Lazarus, C.; Clarke, S.E.M.; Fogelman, I.; Sladen, G.E.

    1993-01-01

    Forty-seven patients, 29 with chronic inflammatory bowel disease (IBD) and 18 with presumed irritable bowel syndrome, including one with uncomplicated diverticular disease, were studied with simultaneous technetium-99m hexamethylpropylene amine oxime and indium-III oxine labelled leucocyte scans performed at 1, 3 and 24 h. Twenty-seven patients with IBD had active disease as judged by clinical and laboratory criteria and all of these had positive scans with both agents. No false positive studies were obtained. The 1-h 99m Tc-HMPAO WBC scans showed the same distribution to disease as the 3-h 111 -In WBC scans, with no difference in intensity (P 111 -In scans. The 3-h 99m Tc-HMPAO WBC scans showed more extensive disease (P 111 In WBC scans. Physiological bowel activity on 3-h 99m Tc-HMPAO WBC scans was present in 12 patients but was faint and did not interfere with assessment of disease extent and activity. It is concluded that in terms of isotope availability, radiation dosimetry and image quality, 99m Tc-HMPAO is the agent of choice in detecting active IBD, with localization of disease possible at 1-h after re-injection and optimal resolution and definition of disease extent at 3 h. A negative scan reliably excludes active disease. (orig.)

  15. Kinetics of platelets in dogs with thrombocytopenia induced by antiglycoprotein IIb/IIIa receptor monoclonal antibody

    International Nuclear Information System (INIS)

    Hosono, Makoto; Sone, Naoaki; Endo, Keigo; Saga, Tsuneo; Kobayashi, Hisataka; Hosono, Masako N.; Sakahara, Harumi; Yasunaga, Kojiro; Konishi, Junji

    1995-01-01

    To experimentally assess the kinetics of platelets in thrombocytopenia, we constructed a canine model using 111 In-oxine labeled autologous platelets and an intact antiplatelet monoclonal antibody (MAb) NNKY2-11 (IgG2a). With the infusion of radiolabeled autologous platelets into dogs, the peripheral platelet count and blood radioactivity level were examined, and the radioactivity in the liver, spleen and heart was determined with scintigraphic analysis. Thereafter, i.v. injection of 100 μg/kg of NNKY2-11 had no effect on platelet counts or the biodistribution of radiolabeled platelets. However, 200 and 300 μg/kg of MAb reduced the platelets, and the radioactivity of the liver and spleen augmented clearly after injection of MAb. Platelet radioactivity in serum, which had decreased after MAb infusion, did not recover, even when peripheral platelet counts returned to the normal levels, indicating that these new platelets might be derived from the platelet-storage pool or new thrombocytogenesis. This model of antiplatelet MAb induced thrombocytopenia seems to be useful for analyzing the kinetics of platelets in thrombocytopenia

  16. Pharmacokinetics of internally labeled monoclonal antibodies as a gold standard: comparison of biodistribution of 75Se-, 111In-, and 125I-labeled monoclonal antibodies in osteogenic sarcoma xenografts in nude mice

    International Nuclear Information System (INIS)

    Koizumi, M.; Endo, K.; Watanabe, Y.; Saga, T.; Sakahara, H.; Konishi, J.; Yamamuro, T.; Toyama, S.

    1989-01-01

    In order to know the true biodistribution of anti-tumor monoclonal antibodies, three monoclonal antibodies (OST6, OST7, and OST15) against human osteosarcoma and control antibody were internally labeled with 75Se by incubating [75Se]methionine and hybridoma cells. 75Se-labeled monoclonal antibodies were evaluated both in vitro and in vivo using the human osteogenic sarcoma cell line KT005, and the results were compared with those of 125I- and 111In-labeled antibodies. 75Se-, 125I- and 111In-labeled monoclonal antibodies had identical binding activities to KT005 cells, and the immunoreactivity was in the decreasing order of OST6, OST7, and OST15. On the contrary, in vivo tumor uptake (% injected dose/g) of 75Se- and 125I-labeled antibodies assessed using nude mice bearing human osteosarcoma KT005 was in the order of OST7, OST6, and OST15. In the case of 111In, the order was OST6, OST7, and OST15. High liver uptake was similarly seen with 75Se- and 111In-labeled antibodies, whereas 125I-labeled antibodies showed the lowest tumor and liver uptake. These data indicate that tumor targeting of antibody conjugates are not always predictable from cell binding studies due to the difference of blood clearance of labeled antibodies. Furthermore, biodistribution of both 111In- and 125I-labeled antibodies are not identical with internally labeled antibody. Admitting that internally labeled antibody is a ''gold standard'' of biodistribution of monoclonal antibody, high liver uptake of 111In-radiolabeled antibodies may be inherent to antibodies. Little, if any, increase in tumor-to-normal tissue ratios of antibody conjugates will be expected compared to those of 111In-labeled antibodies if stably coupled conjugates are administered i.v

  17. Studies on the clinical usefulness of the 111indium chloride bone marrow scintigraphy in patients with aplastic anemia

    International Nuclear Information System (INIS)

    Ino, Teruo; Ito, Naoya; Takeda, Nobuhide

    1985-01-01

    111 Indium chloride ( 111 In-Cl 3 ) appears to be a radionuclide appropriate for a bone marrow scanning because of its physical and chemical characteristics; it is, like iron, bound to and transported by transferrin and it has a photopeak suitable for scintigraphy. This study was undertaken to assess the bone marrow function by 111 In-Cl 3 bone marrow scintigraphy in patients with asplastic anemia. Bone marrow scintigraphy was performed in 21 patients with aplastic anemia with varying degrees of severity including 15 who had no previous treatments. The scintigrams were taken 48 hours after intravenous injection of 111 MBq(3 mCi) of 111 In-Cl 3 . All of them showed various degrees of reduction in uptake of 111 In-Cl 3 by the marrow. The abnormal scan grade was classified into 3 types: Type I, non-accumulation (5); Type II, low-accumulation (15); Type III, uneven accumulation (1). In type III, degree of radioisotope accumulation between the sternum and the ilium was different, and this difference correlated with that of bone marrow cellularity. In 2 patients of type II, hematological improvement occurred after treatment, which was also accompanied by simultaneous increase of 111 In-Cl 3 uptake by the marrow. These findings suggested that the degree of radioisotope accumulation in the marrow reflects that of bone marrow cellularity. Type I patients were clinically severe and poor in prognosis as compared to type II and type III patients; four out of 5 died within 2 months. Bone marrow transplantation may be the treatment of choice in type I patients when feasible. (author)

  18. Novel targeted nuclear imaging agent for gastric cancer diagnosis: glucose-regulated protein 78 binding peptide-guided 111In-labeled polymeric micelles

    Directory of Open Access Journals (Sweden)

    Cheng CC

    2013-04-01

    radioisotope indium-111 (111In was measured and analyzed by instant thin layer chromatography. The coupling efficiency of DTPA-conjugated micelles and DTPA/GRP78BP-conjugated micelles with 111In was 85% and 93%, respectively. For characterization and trace imaging, the radioisotope 111In-targeting tumors were detected and imaged in a xenograft murine model using nano single photon emission computed tomography/computed tomography. The results revealed that the radioactive intensity measured in the animals administered with GRP78BP-guided 111In-labeled micelles was statistically higher than that in animals administered with 111In-labeled micelles, demonstrating that GRP78BP more than doubled the accumulation of micelles to the tumor tissue (P < 0.05. The results indicate that the gastric cancer biomarker GRP78 is a probing target in the application of nuclear imaging for tumor diagnosis. This novel GRP78BP-guided micelle agent may be applied in clinical practice to complement the histological diagnosis.Keywords: biomarker, glucose-regulated protein 78, nuclear imaging, gastric cancer, micelles

  19. Comparison of in-vivo kinetics of an antibody cocktail containing 131-iodine anti-CA-19/9 and 131-iodine anti-CEA with 111-indium labelled monoclonal anti-CA-19/9 using a tumor model in mice

    International Nuclear Information System (INIS)

    Koenig, S.; Orth, M.; Henze, E.

    1993-01-01

    In this study the potential diagnostic value of an 111-In-labelled CA-19/9-F (ab)-fragment was compared to that of an antibody cocktail of 131-iodine-labelled CA-19/9 and 131-iodine-labelled anti-CEA for identification of pancreas cancer by a nude mice model. 111-In-labelled CA-19/9 and the 131-iodine antibody cocktail were injected into 35 nude mice xenotransplantated with human pancreas cancer. Scintigrams were obtained and the relative distribution of activity in tumor and in several organs were determined by ROI-technique. These values were compared with the in vitro results of organ measurement after dissection of nude mice. Blood pool of 131-iodine-labelled antibodies showed only a nuclide accumulation in the thyroid because of very high rate of dejodination and missing blockade of thyroid. Other organs were not detectabel in scintigraphy because of high nucleotide accumulation of thyroid. The tumor-to-blood-ratio of organ-measurements was 18±4.3, kidneys-background-ratio 2.1±7.3, liver-background-ratio 5.8±2.0. These results are similar to those of 111-In-labelled fragments. Thus it is established that antibody cocktail had no essential advantage over singular antibody in mouse model. It gives a good tumor contrast with tumor-background-quotient of 15±7.4 measured by scintigraphy and tumor background-quotient 18±4.3 in-vitro-organ-measurement. (orig.) [de

  20. Differential labeling of platelet alpha 2 adrenoceptors by 3H dihydroergocryptine and 3H yohimbine in patients with myeloproliferative disorders

    International Nuclear Information System (INIS)

    Swart, S.S.; Wood, J.K.; Barnett, D.B.

    1985-01-01

    Platelet alpha adrenoceptor status was examined using the radioligands 3 H-yohimbine ( 3 H-YOH) and 3 H-dihydroergocryptine ( 3 H-DHE) in 14 patients with myeloproliferative disorder (MPD) and 10 normal controls. Platelets from normal controls and MPD patients sensitive to adrenaline induced aggregation exhibited approximately 50% more binding sites identified by 3 H-DHE than 3 H-YOH, whereas MPD platelets insensitive to adrenaline showed selective loss of these extra 3 H-DHE sites. In functional studies after 30 minutes preincubation with the unlabelled antagonists, DHE was more potent than YOH at inhibiting adrenaline induced aggregation in normal platelets. In addition, the affinity constant for DHE was virtually identical in binding and functional experiments, whereas for YOH the affinity constant for binding was approximately 10 fold more potent than that for aggregation. These results suggest that the alpha adrenoceptor binding site on human platelets labelled by 3 H-DHE may be of more functional relevance than that labelled by 3 H-YOH alone

  1. Indium 111 DTPA in cisternography

    International Nuclear Information System (INIS)

    Moretti, J.L.; Boumati, P.; Vilayleck, S.

    The circulation of the cerebrospinal fluid was studied in 11 patients following injection of 111 In DTPA. Because of its biological, radioactive and chemical characteristics, it is an ideal radiopharmaceutical [fr

  2. In-111 labeled leukocyte scintigraphy in patients with suspected inflammation after failed antibiotic therapy

    International Nuclear Information System (INIS)

    Nasu, Reiko; Akagi, Kiyoshi; Murata, Takashi; Uokawa, Kyousuke; Isoda, Hiroyoshi; Tanaka, Yoshimasa; Itagaki, Yasushi

    1998-01-01

    In-111 labeled leukocyte scintigrapy (In-111 WBC scan) was performed in 16 patients with inflammation suspected on the basis of laboratory findings, symptoms, and diagnostic imaging, but who had failed antibiotic therapy. In-111 WBC scans revealed an abnormal focus of radiotracer activity (positive scans) in five of 16 patients. No correlation was found between the peripheral WBC count and accumulation of In-111 WBC. Inflammatory disease suspected on the basis of the CRP level should be considered when In-111 WBC scanning results in negative findings. Our results indicated that In-111 WBC scanning has low sensitivity after antibiotic therapy. Selection of patients on the basis of persistent elevation of CRP may be valuable. (author)

  3. Splenic microenvironment and self recognition as factors in allograft rejection in rats. A study using indium-111-labeled cells

    International Nuclear Information System (INIS)

    Pollak, R.; Blanchard, J.M.; Lazda, V.A.

    1986-01-01

    Splenectomy facilitates organ allograft survival in some rat strains, and in weak donor-recipient histoincompatible pairs. We have found using a heart spleen twin graft model, using ACI rats as recipients and Lewis rats as donors, that the transplanted heart will survive in most recipients after delayed host splenectomy. The presence of a viable mass of splenic tissue will allow rejection to proceed only when the transplanted spleen is of host origin, and not when it comes from the donor (i.e., when it is allogeneic). The use of 111In-labeled cells has allowed us to show that lymphocyte traffic and trapping is markedly altered in the transplanted allogeneic spleens, when compared with control transplanted syngeneic spleens. Thus, despite the presence of the splenic ''microenvironment,'' cardiac allograft rejection does not occur in the absence of syngeneic splenic tissue. We conclude that the role of the spleen in the immune response is to facilitate the recognition of self and the acquisition of alloreactivity in weak responder rat strains and donor-recipient pairs

  4. Comparison of oral iodine-131-cellulose and indium-111-DTPA as tracers for colon transit scintigraphy: Analysis by colon activity profiles

    International Nuclear Information System (INIS)

    Smart, R.C.; McLean, R.G.; Gaston-Parry, D.; Barbagallo, S.; Bruck, C.E.; King, D.W.; Lubowski, D.Z.; Talley, N.A.

    1991-01-01

    In 11 normal subjects and 11 patients with a clinical diagnosis of constipation, oral 131I-cellulose and 111In-DTPA were compared simultaneously as tracers for radionuclide colon transit scintigraphy. Visual assessment of the images revealed no differences between tracers. Quantitation was performed using total and segmental percent retention and the derived value of clearance half-time. In addition, profiles of the activity distribution along the length of the colon were generated and the mean position of the activity in the colon calculated. For all indices, the results were similar in both normal subjects and constipated patients when comparing tracers, although marked differences were present between normal subjects and constipated patients for each tracer. Indium-111-DTPA was easy to administer and dosimetry was more acceptable than for 131I-cellulose, especially in constipated patients. It is concluded that 111In-DTPA is the preferred tracer for oral colon transit scintigraphy

  5. Preparation of [In-111]-labeled-DTPA-bombesin conjugates at high specific activity and stability: Evaluation of labeling parameters and potential stabilizers

    Energy Technology Data Exchange (ETDEWEB)

    Pujatti, P.B., E-mail: pujatti.pb@gmail.com [Directory of Radiopharmacy, Nuclear and Energy Research Institute (IPEN/CNEN), Av. Prof. Lineu Prestes, 2242 - Cidade Universitaria da USP - Butanta, Sao Paulo - SP - Brazil - CEP: 05508-000 (Brazil); Massicano, A.V.F.; Mengatti, J.; Araujo, E.B. de [Directory of Radiopharmacy, Nuclear and Energy Research Institute (IPEN/CNEN), Av. Prof. Lineu Prestes, 2242 - Cidade Universitaria da USP - Butanta, Sao Paulo - SP - Brazil - CEP: 05508-000 (Brazil)

    2012-05-15

    The aim of the present work was to obtain stabilized high specific activity (HSA) {sup 111}In-labeled bombesin conjugates for preclinical evaluations. Parameters influencing the kinetics of labeling were investigated and the effect of stabilizers on HSA radiopeptides stability at room temperature were systematically categorized applying chromatography techniques. A SA of 174 GBq/{mu}mol was achieved with high radiochemical purity, but the labeled compounds exhibited low stability. The addition of stabilizers avoided their radiolysis and significantly increased their stability. - Highlights: Black-Right-Pointing-Pointer We aimed to obtain stabilized high specific activity (SA) {sup 111}In-labeled bombesin conjugates. Black-Right-Pointing-Pointer The effect of stabilizers on high SA radiopeptides stability were investigated. Black-Right-Pointing-Pointer A maximum specific activity of 174 GBq/{mu}mol was achieved. Black-Right-Pointing-Pointer The studied stabilizers significantly increased the stability of high SA radiopeptides. Black-Right-Pointing-Pointer These stabilized bombesin conjugates will be applied in preclinical studies.

  6. Multimodality Molecular Imaging of [18F]-Fluorinated Carboplatin Derivative Encapsulated in [111In]-Labeled Liposomes

    Science.gov (United States)

    Lamichhane, Narottam

    -(5-fluoro-pentyl)-2-methyl malonic acid as the labeling agent to coordinate with the cisplatin aqua complex. It was then used to treat various cell lines and compared with cisplatin and carboplatin at different concentrations ranging from 0.001 microM to 100 microM for 72 hrs and 96 hrs. IC50 values calculated from cell viability indicated that 19F-FCP is a more potent drug than Carboplatin. Manual radiosynthesis and characterization of [18F]-FCP was performed using [18F]-2-(5-fluoro-pentyl)-2-methyl malonic acid with coordination with cisplatin aqua complex. Automated radiosynthesis of [18F]-FCP was optimized using the manual synthetic procedures and using them as macros for the radiosynthesizer. [18F]-FCP was evaluated in vivo with detailed biodistribution studies and PET imaging in normal and KB 3-1 and KB 8-5 tumor xenograft bearing nude mice. The biodistribution studies and PET imaging of [18F]-FCP showed major uptake in kidneys which attributes to the renal clearance of radiotracer. In vivo plasma and urine stability demonstrated intact [18F]-FCP. [ 111In]-Labeled Liposomes was synthesized and physiochemical properties were assessed with DLS. [111In]-Labeled Liposome was evaluated in vivo with detailed pharmacokinetic studies and SPECT imaging. The biodistribution and ROI analysis from SPECT imaging showed the spleen and liver uptake of [111In]-Labeled Liposome and subsequent clearance of activity with time. [18F]-FCP encapsulated [111In]-Labeled Liposome was developed and physiochemical properties were characterized with DLS. [18F]-FCP encapsulated [111In]-Labeled Liposome was used for in vivo dual tracer PET and SPECT imaging from the same nanoconstruct in KB 3-1 (sensitive) and COLO 205 (resistant) tumor xenograft bearing nude mice. PET imaging of [18F]-FCP in KB 3-1 (sensitive) and COLO 205 (resistant) tumor xenograft bearing nude mice was performed. Naked [18F]-FCP and [18F]-FCP encapsulated [ 111In]-Labeled Liposome showed different pharmacokinetic profiles. PET

  7. Serial in vivo imaging of the porcine heart after percutaneous, intramyocardially injected 111In-labeled human mesenchymal stromal cells

    DEFF Research Database (Denmark)

    Lyngbaek, Stig; Ripa, Rasmus S; Haack-Sørensen, Mandana

    2010-01-01

    This pilot trial aimed to investigate the utilization of (111)In-labeling of mesenchymal stromal cells (MSC) for in vivo tracking after intramyocardial transplantation in a xenotransplantation model with gender mismatched cells. Human male MSC were expanded ex vivo and labeled with (111)In...

  8. Serial in vivo imaging of the porcine heart after percutaneous, intramyocardially injected (111)In-labeled human mesenchymal stromal cells

    DEFF Research Database (Denmark)

    Lyngbæk, Stig; Ripa, Rasmus Sejersten; Haack-Sørensen, Mandana

    2009-01-01

    This pilot trial aimed to investigate the utilization of (111)In-labeling of mesenchymal stromal cells (MSC) for in vivo tracking after intramyocardial transplantation in a xenotransplantation model with gender mismatched cells. Human male MSC were expanded ex vivo and labeled with (111)In...

  9. Human plasma fibrinogen adsorption and platelet adhesion to polystyrene.

    Science.gov (United States)

    Tsai, W B; Grunkemeier, J M; Horbett, T A

    1999-02-01

    The purpose of this study was to further investigate the role of fibrinogen adsorbed from plasma in mediating platelet adhesion to polymeric biomaterials. Polystyrene was used as a model hydrophobic polymer; i.e., we expected that the role of fibrinogen in platelet adhesion to polystyrene would be representative of other hydrophobic polymers. Platelet adhesion was compared to both the amount and conformation of adsorbed fibrinogen. The strategy was to compare platelet adhesion to surfaces preadsorbed with normal, afibrinogenemic, and fibrinogen-replenished afibrinogenemic plasmas. Platelet adhesion was determined by the lactate dehydrogenase (LDH) method, which was found to be closely correlated with adhesion of 111In-labeled platelets. Fibrinogen adsorption from afibrinogenemic plasma to polystyrene (Immulon I(R)) was low and polystyrene preadsorbed with fibrinogen-replenished afibrinogenemic plasma. Addition of even small, subnormal concentrations of fibrinogen to afibrinogenemic plasma greatly increased platelet adhesion. In addition, surface-bound fibrinogen's ability to mediate platelet adhesion was different, depending on the plasma concentration from which fibrinogen was adsorbed. These differences correlated with changes in the binding of a monoclonal antibody that binds to the Aalpha chain RGDS (572-575), suggesting alteration in the conformation or orientation of the adsorbed fibrinogen. Platelet adhesion to polystyrene preadsorbed with blood plasma thus appears to be a strongly bivariate function of adsorbed fibrinogen, responsive to both low amounts and altered states of the adsorbed molecule. Copyright 1999 John Wiley & Sons, Inc.

  10. Pulmonary emboli from blood-biomaterial interaction

    International Nuclear Information System (INIS)

    Coleman, J.E.; Ramberg, K.; McEnroe, C.S.; Connolly, R.J.; Callow, A.D.

    1988-01-01

    The problem of surface thrombosis and subsequent embolization remains entrenched as a yet incompletely surmounted barrier to the development of truly satisfactory intravascular prosthetic devices. A baboon ex vivo shunt was used to determine the interaction of Indium-111 platelets and potential biomaterials. The uptake of Indium-111 platelets was monitored continuously by gamma camera scanning. Several of the materials tested demonstrated a saw-toothed pattern of platelet activity, with accumulation followed by rapid decline. Neither PTFE nor Dacron exhibited this pattern. Post shunt scans of the animals' chests showed discrete foci of platelet activity in the lungs, corresponding to each embolic event noted on the material's scan. In conclusion, the search for a smooth surface as a blood material interface may produce a material which accumulates and then sloughs significant platelet aggregates. It is crucial that these materials be subjected to vigorous testing to determine their safety prior to initiation of clinical trials

  11. Comparative evaluation of red cell-labelling parameters of three lipid-soluble 111-In-chelates: Effect of lipid solubility on membrane incorporation and stability constant on transchelation

    International Nuclear Information System (INIS)

    Rao, S.A.; Dewanjee, M.K.

    1982-01-01

    A rabbit red cell model was used to determined the cell labeling properties of three lipid-soluble 111 In-complexes: 111 In-oxine, 111 In-acetylacetone, and 111 In-tropolone. Partition coefficients (olive oil/buffer) were measured to determine the lipid solubility and were 3.54, 7.93, and 18.18 for 111 In-oxine, 111 In-acetylacetone, and 111 In-tropolone respectively. The effect of the concentration of these three chelating agents on labeling efficiencies was studied. The factors influencing the labeling efficiencies of these complexes such as cell density, time of incubation, influence of temperature, pH, effect of plasma proteins, and citrate ion concentration in the cell-labeling medium were studied. Labeling yields as high as 95.15 +- 4.15% were achieved with 111 In-tropolone after a 10-min incubation at 37 0 C. The optimum pH for cell labeling was 6.5 Excess critrate ion (> 3.02 mg/ml) and small amounts of plasma proteins (> 10 μl/ml) decreased the labeling efficiencies in all three cases. Distribution of these 111 In-complexes in membrane, membrane frgments, and hemoglobin was studied after hemolysis. In spite of the higher lipid solubility of 111 In-tropolone, the transchelation capacity appears to be similar to that of 111 In-oxine. 111 In-acetylacetone had the highest transchelation capacity. (orig.)

  12. Evaluation of biodistribution and imaging of atherosclerotic lesions using 111In-labeled low-density lipoprotein

    International Nuclear Information System (INIS)

    Yamashina, Hisayo

    1993-01-01

    111 In-labeled low-density lipoprotein (LDL) was administered to Watanabe heritable hyperlipidemic rabbits (WHHL group) and control rabbits (control group) to evaluate its biodistribution and scintigraphic images by γ-camera and radioactivity of each organ. With external imaging, the heart, liver, kidney, bone and spleen of each rabbit were observed. By setting the region of interest, the liver/heart ratio of the WHHL group was significantly lower than that of the control group (p 111 In-labeled-LDL was recognized in the aortic arch, bifurcation of intercostal and celiac artery in the WHHL group. By the use of labeled LDL with the combination of γ-camera, it is capable of detecting the regulation of lipoprotein metabolism and imaging atherosclerotic lesions externally. (author)

  13. 21 CFR 111.455 - What requirements apply to holding components, dietary supplements, packaging, and labels?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What requirements apply to holding components, dietary supplements, packaging, and labels? 111.455 Section 111.455 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD...

  14. 111In-labeled lactam bridge-cyclized alpha-melanocyte stimulating hormone peptide analogues for melanoma imaging.

    Science.gov (United States)

    Miao, Yubin; Gallazzi, Fabio; Guo, Haixun; Quinn, Thomas P

    2008-02-01

    The purpose of this study was to examine the influence of the lactam bridge cyclization on melanoma targeting and biodistribution properties of the radiolabeled conjugates. Two novel lactam bridge-cyclized alpha-MSH peptide analogues, DOTA-CycMSH (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid-c[Lys-Nle-Glu-His-DPhe-Arg-Trp-Gly-Arg-Pro-Val-Asp]) and DOTA-GlyGlu-CycMSH (DOTA-Gly-Glu-c[Lys-Nle-Glu-His-DPhe-Arg-Trp-Gly-Arg-Pro-Val-Asp]), were synthesized and radiolabeled with (111)In. The internalization and efflux of (111)In-labeled CycMSH peptides were examined in B16/F1 melanoma cells. The melanoma targeting properties, pharmacokinetics, and SPECT/CT imaging of (111)In-labeled CycMSH peptides were determined in B16/F1 melanoma-bearing C57 mice. Both (111)In-DOTA-CycMSH and (111)In-DOTA-GlyGlu-CycMSH exhibited fast internalization and extended retention in B16/F1 cells. The tumor uptake values of (111)In-DOTA-CycMSH and (111)In-DOTA-GlyGlu-CycMSH were 9.53+/-1.41% injected dose/gram (% ID/g) and 10.40+/-1.40% ID/g at 2 h postinjection, respectively. Flank melanoma tumors were clearly visualized with (111)In-DOTA-CycMSH and (111)In-DOTA-GlyGlu-CycMSH by SPECT/CT images at 2 h postinjection. Whole-body clearance of the peptides was fast, with greater than 90% of the radioactivities cleared through urinary system by 2 h postinjection. There was low radioactivity (<0.8% ID/g) accumulated in blood and normal organs except kidneys at all time points investigated. Introduction of a negatively charged linker (-Gly-Glu-) into the peptide sequence decreased the renal uptake by 44% without affecting the tumor uptake at 4 h postinjection. High receptor-mediated melanoma uptakes coupled with fast whole-body clearance in B16/F1 melanoma-bearing C57 mice demonstrated the feasibility of using (111)In-labeled lactam bridge-cyclized alpha-MSH peptide analogues as a novel class of imaging probes for receptor-targeting melanoma imaging.

  15. Comparison of biological properties of 111In-labeled dimeric cyclic RGD peptides

    International Nuclear Information System (INIS)

    Zheng, Yumin; Ji, Shundong; Tomaselli, Elena; Yang, Yong; Liu, Shuang

    2015-01-01

    Introduction: In this study two 111 In-labeled dimeric cyclic RGD peptides, 111 In(DOTA-Galacto-RGD 2 ) and 111 In(DOTA-3P-RGD 2 ), were evaluated as radiotracers for breast tumor imaging. The objective was to evaluate the impact of SAA, PEG 2 and 1,2,3-triazole linkers as compare to PEG 4 on the tumor uptake and excretion kinetics of 111 In radiotracers. Methods: DOTA-Galacto-RGD 2 was prepared by conjugation of Galacto-RGD 2 with DOTA-OSu in the presence of diisopropylethylamine. Its integrin α v β 3 binding affinity was determined using a whole-cell displacement assay against 125 I-echistatin bound to U87MG glioma cells, and was compared with those of c(RGDfK), DOTA-3P-RGD 2 and DOTA-3P-RGK 2 (a nonsense peptide conjugate with “scrambled” RGK sequences). 111 In(DOTA-Galacto-RGD 2 ) and 111 In(DOTA-3P-RGD 2 ) were prepared and evaluated for their tumor-targeting capability and biodistribution properties in athymic nude mice bearing MDA-MB-435 breast tumor xenografts. Planar imaging studies were performed to demonstrate the utility of 111 In(DOTA-Galacto-RGD 2 ) and 111 In(DOTA-3P-RGD 2 ) for breast tumor imaging. Results: IC 50 values of DOTA-Galacto-RGD 2 , DOTA-3P-RGD 2 , and DOTA-3P-RGK 2 were calculated to be 27 ± 2, 29 ± 4, 596 ± 48 nM, respectively. The tumor uptake values of 111 In(DOTA-Galacto-RGD 2 ) (6.79 ± 0.98, 6.56 ± 0.56, 4.17 ± 0.61 and 1.09 ± 0.13 %ID/g at 1, 4, 24 and 72 hours p.i., respectively) were almost identical to those of 111 In(DOTA-3P-RGD 2 ) (6.17 ± 1.65, 5.94 ± 0.84, 3.40 ± 0.50 and 0.99 ± 0.20 %ID/g, respectively). 111 In(DOTA-Galacto-RGD 2 ) had a faster clearance from blood and muscle than 111 In(DOTA-3P-RGD 2 ), leading to higher tumor/blood and tumor/muscle ratios. 111 In(DOTA-3P-RGD 2 ) had lower liver uptake and better tumor/liver ratios than 111 In(DOTA-Galacto-RGD 2 ). The tumor uptake of 111 In(DOTA-Galacto-RGD 2 ) and 111 In(DOTA-3P-RGD 2 ) was both integrin α v β 3 and RGD-specific. Imaging data suggest

  16. Evidence that platelet buoyant density, but not size, correlates with platelet age in man

    International Nuclear Information System (INIS)

    Mezzano, D.; Hwang, K.; Catalano, P.; Aster, R.H.

    1981-01-01

    Following infusion of 51Cr-labeled autologous platelets into normal subjects, high-density (HD) and low-density (LD) platelet cohorts were isolated by prolonged centrifugation in isosmotic arabino-galactan (Stractan). Specific radio-activity of LD platelets declined rapidly post-infusion (T1/2 . 1.5 days), but specific radioactivity of HD platelets remained constant or increased over a 3--4-day period and gradually declined for 6--7 days thereafter. These differences were exaggerated when platelet cohorts enriched in LD or HD cells by slow centrifugation in high-density albumin were labeled and transfused. Mean survival of a platelet cohort enriched with HD cells was significantly (P less than 0.02) shorter (7.73 days) than that of a cohort enriched with LD cells (9.33) days). In normal subjects treated with aspirin, capacity for thromboxane synthesis was regained more rapidly (P less than 0.05) in LD than in HD platelets. HD and LD platelets differed only slightly in mean volume (HD platelets . 7.57 mu3, LD platelets . 6.87 mu3, 0.05 less than P less than 0.01). We believe the most logical interpretation of these findings is that under normal conditions in man, newly formed platelets are less dense on the average than total platelets and become more dense as they age in the circulation. Thus, specific radioactivity of LD platelets declines rapidly as these platelets move into a more dense compartment and are replaced by newly formed, unlabelled cells; specific radioactivity of HD platelets remains constant or increases as labelled platelets enter this compartment in numbers equal to or greater than the number leaving it at the end of their life span. The similarity in mean volumes of LD and HD platelets suggests that platelet size is unrelated to platelet age under normal conditions

  17. Indium-111-labeled B72. 3 monoclonal antibody in the detection and staging of breast cancer: A phase 1 study

    Energy Technology Data Exchange (ETDEWEB)

    Lamki, L.M.; Buzdar, A.U.; Singletary, S.E.; Rosenblum, M.G.; Bhadkamkar, V.; Esparza, L.; Podoloff, D.A.; Zukiwski, A.; Hortobagyi, G.N.; Murray, J.L. (Department of Nuclear Medicine, University of Texas M.D. Anderson Cancer Center, Houston (USA))

    1991-07-01

    Sixteen patients with primary breast cancer were studied with a pancarcinoma monoclonal antibody B72.3, an IgG1 molecule directed against tumor-associated glycoprotein (TAG-72) present in several tumors. Five millicuries of 111In was used to label 0.2 mg (six patients), or 2 mg (six patients), or 20 mg using the site-directed bifunctional DTPA method (at carbohydrate moiety). Digital, planar, and SPECT images were obtained at 2, 48, 72 and 96 hr when possible. HAMA levels were obtained before the Mab infusion and at 1, 3, and 6 wk postinfusion. Fourteen of 14 known primary breast lesions were detected by imaging (100% sensitivity). Two fibrocystic lesions were negative. Seven of 14 patients had lymph node metastases by histologic methods, but all were missed by radioimmunoscintigraphy. Tumor uptake of Mab ranged 0.00054%-0.0038% of the ID/g. The tumor-to-normal breast tissue ratio was 4.3 {plus minus} 0.91 (mean {plus minus} s.e.m.). Lymph nodes localization of 111In-B72.3 by tissue analysis was similar for tumor-bearing and normal nodes (0.0039 {plus minus} 0.0023 versus 0.0025 {plus minus} 0.0019). Pharmacokinetics revealed mean plasma half-life of 33.3-41.2 hr for the different doses. There was no statistical difference between any of the pharmacokinetic parameters of different doses. HAMA was positive only in 17% of the patients. The study suggests that this antibody has 100% sensitivity for primary breast cancers, but very poor detection rate of metastatic lesions in axillary lymph nodes; thus making it of questionable value in the initial staging process of this disease.

  18. Platelet-collagen adhesion enhances platelet aggregation induced by binding of VWF to platelets

    International Nuclear Information System (INIS)

    Laduca, F.M.; Bell, W.R.; Bettigole, R.E.

    1987-01-01

    Ristocetin-induced platelet aggregation (RIPA) was evaluated in the presence of platelet-collagen adhesion. RIPA of normal donor platelet-rich plasma (PRP) demonstrated a primary wave of aggregation mediated by the binding of von Willebrand factor (VWF) to platelets and a secondary aggregation wave, due to a platelet-release reaction, initiated by VWF-platelet binding and inhibitable by acetylsalicylic acid (ASA). An enhanced RIPA was observed in PRP samples to which collagen had been previously added. These subthreshold concentrations of collagen, which by themselves were insufficient to induce aggregation, caused measurable platelet-collagen adhesion. Subthreshold collagen did not cause microplatelet aggregation, platelet release of [ 3 H]serotonin, or alter the dose-responsive binding of 125 I-labeled VWF to platelets, which occurred with increasing ristocetin concentrations. However, ASA inhibition of the platelet release reaction prevented collagen-enhanced RIPA. These results demonstrate that platelet-collagen adhesion altered the platelet-release reaction induced by the binding of VWF to platelets causing a platelet-release reaction at a level of VWF-platelet binding not normally initiating a secondary aggregation. These findings suggest that platelet-collagen adhesion enhances platelet function mediated by VWF

  19. Stimulus-response coupling in platelets

    International Nuclear Information System (INIS)

    Huang, E.M.

    1986-01-01

    To understand the mechanism of stimulus-response coupling in platelets, the potentiating effect of succinate and lithium on platelet activation was examined. The action of succinate was immediate; preincubation with succinate did not lead to desensitization. Succinate was comparable to ADP in lowering cAMP levels previously elevated by PGl 2 . Since inhibition of cAMP is not a prerequisite for platelet activation, the mechanism of potentiation of succinate remains undefined. Lithium has also been shown to inhibit adenylate cyclase in PGl 2 -pretreated platelets. Lithium, however, can also inhibit inositol phosphate (InsP) phosphatase and lead to an accumulation of InsP. In human platelets, lithium also enhanced the thrombin-induced accumulation of [ 3 H]inositol-labelled inositol trisphosphate (InsP 3 ), and inositol bisphosphate (InsP 2 ). One hour after thrombin addition, all 3 inositol phosphates returned to near basal levels. In the presence of lithium, while labelled InsP 2 and InsP 3 returned to their respective basal levels, the InsP level remained elevated, consistent with the known inhibitory effect of lithium on InsP phosphatase. In thrombin-stimulated platelets prelabeled with [ 32 P]phosphate, lithium led to a decrease in labelled phosphatidylinositol 4-phosphate (PtdIns4P) as well as an enhanced production of labelled lysophosphatidylinositol, suggesting multiple effects of lithium on platelet phosphoinositide metabolism. These observed effects, however, occurred too slowly to be the mechanism by which lithium potentiated agonist-induced platelet activation. To study the agonist-receptor interaction, the effect of the specific, high affinity thrombin inhibitor, hirudin, on thrombin-induced accumulation of [ 3 H]inositol-labelled inositol phosphates was studied

  20. Comparison between 67-gallium citrate of exametazine-T-99m labelled leucocites and the DTPA-indio-111 labelled G immunoglobuline in the diagnosis of bone and articular infections

    International Nuclear Information System (INIS)

    Ramos, Paulo Alberto de Lima; Martin-Comin, Josep; Roca, Manel; Ricart, Ivone; Castell, Manuel; Mora, Jaume; Puchal, Rafael; Ramos, Miguel

    2000-01-01

    The aim of this study was to compare the ability of 67-Gallium citrate (67Ga), 99m-Tc labelled leucocytes (99mTc-WBC) and 111-In-labelled immunoglobulin G (111In-IgG) scintigraphy in bone and joint infections diagnosis. Fifty-six patients were studied. For all patients a bone scan using 99mTc-MDP was indicated. The patients were randomized allocated for 67Ga (Group 1 - 22 patients) or simultaneous administration 99mTc-labelled leucocytes and 111In-IgG.(Group 2 - 34 patients) study. For the groups 1 and 2 were confirmed respectively 12/26 y 11/34 septic lesions. The 67Ga scintigraphy showed 6 true-positive, 9 true-negative, 5 false-positive and 6 false-negative. With 99mTc-WBC, the respective values were 8, 18, 5 and 3. With 111In-IgG, the figures were 7, 17, 6 and 4, respectively. The sensitivity, specificity and accuracy were 50%, 64,3% and 57,7% respectively for the 67Ga, 72,7%, 78,2% and 76,4% respectively for 99mTc-WBC and 63,6%, 73,9% and 70,6% respectively for 111In-IgG. In this study, the labelled leucocytes scintigraphy showed more accurate than 67Ga and 111In-IgG scans for the diagnosis of bone and joint infections. However, the obtained results were less reliable for the diagnosis of occult sepsis in the patients with joint prosthesis (Au)

  1. Quantification of extracorporal platelet deposition in cardiopulmonary bypass: Effects of ZK 36374, a prostacyclin analogue

    Energy Technology Data Exchange (ETDEWEB)

    Martin, W.; Spyt, T.; Wheatley, D.J.; Thomas, I.; Davidson, J.F.

    1989-03-01

    The degree of extracorporal platelet sequestration in 32 patients undergoing cardiopulmonary bypass has been assessed using /sup 111/In labelled platelets and both a shadow shield whole body monitor and a standard gamma camera. The effects of ZK 36374, a prostacyclin analogue, on deposition of platelets in the oxygenator and atrial line filter were also investigated. Total platelet deposition in the placebo group ranged from 2.2% to 31.7%, mean 13.9+-7.8%; n=15, and was significantly higher than the deposition in the treatment group, range 0.7% to 9.4%, mean 3.9+-2.6%; n=16, P < 0.001. There was also a highly significant correlation between the gamma camera and whole body monitor measurements, r=0.99, P < 0.001, with no systematic difference between the techniques. This study demonstrates that accurate quantitative assessment of platelet deposition can be achieved with either the gamma camera or whole body monitor. In addition, significant reduction in platelet sequestration in the extracorporal circuit can be achieved by using ZK 36374 during the bypass operation.

  2. Gastrointestinal scintigraphy using sup(99m)Tc- or 111In-labelled polymer beads

    International Nuclear Information System (INIS)

    Jordaan, J.H.; Dormehl, I.C.; Pilloy, W.J.

    1984-01-01

    In order to establish normal and pathological stomach emptying characteristics by external measurement of a radioactive meal using a gamma camera and computer system, it is necessary for the radioactively labelled substance to have the same behaviour in the stomach as the ingested food. Resins containing chelating groups which enable binding to either reduced sup(99m)TcO 4 - or 111 In +3 were tested for their suitability as tracers mixed into solid food. The preparation of such styrene-divinyl-benzene resins containing either triethylenetetramine substituents or the fully carboxymethylated derivatives is discussed, as well as the procedures of labelling with either sup(99m)Tc-pertechnetate or 111 In-chloride. An evaluation of the resins for gastrointestinal scintigraphy was performed on 3 chacma baboons and a male human volunteer with encouraging results. (orig.) [de

  3. Photoemission and low energy electron microscopy study on the formation and nitridation of indium droplets on Si (111)7 × 7 surfaces

    International Nuclear Information System (INIS)

    Qi, B.; Ólafsson, S.; Göthelid, M.; Gislason, H.P.; Agnarsson, B.

    2013-01-01

    The formation and nitridation of indium (In) droplets on Si (111)7 × 7, with regard to In droplet epitaxy growth of InN nanostructures, were studied using a spectroscopic photoemission and low energy electron microscopy, for the In coverages from 0.07 to 2.3 monolayer (ML). The results reveal that the In adatoms formed well-ordered clusters while keeping the Si (111)7 × 7 surface periodicity at 0.07 ML and a single √(3)×√(3) phase at 0.3 ML around 440–470 °C. At 0.82 ML, owing to the presence of structurally defect areas beside the 7 × 7 domains, 3-D In droplets evolved concomitantly with the formation of 4 × 1-In cluster chains, accompanied by a transition in surface electric property from semiconducting to metallic. Further increasing the In to 2.3 ML led to a moderate increase in number density and an appreciable lateral growth of the droplets, as well as the multi-domain In phases. Upon nitridation with NH 3 at ∼ 480 °C, besides the nitridation of the In droplets, the N radicals also dissociated the In-Si bonds to form Si-N. This caused a partial disintegration of the ordered In phase and removal of the In adatoms between the In droplets. - Highlights: ► Formation and nitridation of indium (In) droplets on Si (111) were studied. ► In droplets evolved with the 4 × 1-In cluster chains at 0.82 monolayer (ML). ► In droplets grow in density and lateral size with In coverage increased to 2.3 ML. ► The multi-domain In phases were formed at 2.3 ML. ► Nitridation of In droplets is accompanied by a disintegration of layering In phase

  4. Human platelet glycoprotein Ia. One component is only expressed on the surface of activated platelets and may be a granule constituent

    International Nuclear Information System (INIS)

    Bienz, D.; Clemetson, K.J.

    1989-01-01

    Glycoprotein Ia (GP Ia) is a relatively minor component of human blood platelets thought to be a receptor involved in collagen-induced platelet activation. However, some difficulties exist with the definition of this glycoprotein. The expression of GP Ia on resting (prostacyclin analogue-treated) and thrombin-activated platelets was compared by surface labeling with 125 I-lactoperoxidase. Intact platelets or platelets solubilized in sodium dodecyl sulfate were labeled with periodate/[ 3 H]NaBH 4 . Analysis on two-dimensional isoelectric focusing/sodium dodecyl sulfate-polyacrylamide gel electrophoresis gels showed that GP Ia is very poorly labeled in resting platelets. After activation a new spot (GP Ia*) appears with the same relative molecular mass as GP Ia under reducing conditions. GP Ia and Ia* can be clearly separated by two-dimensional nonreduced/reduced gel electrophoresis. Therefore, two glycoproteins which have been termed GP Ia exist in platelets with similar molecular weight and pI under reducing conditions. One of these (GP Ia*) is only surface-labeled when platelets are activated, indicating that it is only exposed on the surface of activated platelets. Supernatant from activated platelets contains this glycoprotein as well as other granule components. This glycoprotein is missing in platelets from two patients with collagen-response defects

  5. Failure of 111In-labeled bleomycin tumor scanning to predict response to bleomycin (NSC-125066) treatment

    International Nuclear Information System (INIS)

    Jones, S.E.; Salmon, S.E.; Durie, B.G.M.

    1974-01-01

    The question of whether or not 111 In-labeled bleomycin is predictive of the response of tumors to bleomycin treatment is answered in the negative. The real test of the value of labeled bleomycin as a predictor of response will be possible only when a tightly labeled bleomycin with fully preserved biologic activity is synthesized. The negative results of this study do not invalidate further investigations of the predictive values of labeled anticancer drugs

  6. Correlative scanning electron and confocal microscopy imaging of labeled cells coated by indium-tin-oxide

    KAUST Repository

    Rodighiero, Simona

    2015-03-22

    Confocal microscopy imaging of cells allows to visualize the presence of specific antigens by using fluorescent tags or fluorescent proteins, with resolution of few hundreds of nanometers, providing their localization in a large field-of-view and the understanding of their cellular function. Conversely, in scanning electron microscopy (SEM), the surface morphology of cells is imaged down to nanometer scale using secondary electrons. Combining both imaging techniques have brought to the correlative light and electron microscopy, contributing to investigate the existing relationships between biological surface structures and functions. Furthermore, in SEM, backscattered electrons (BSE) can image local compositional differences, like those due to nanosized gold particles labeling cellular surface antigens. To perform SEM imaging of cells, they could be grown on conducting substrates, but obtaining images of limited quality. Alternatively, they could be rendered electrically conductive, coating them with a thin metal layer. However, when BSE are collected to detect gold-labeled surface antigens, heavy metals cannot be used as coating material, as they would mask the BSE signal produced by the markers. Cell surface could be then coated with a thin layer of chromium, but this results in a loss of conductivity due to the fast chromium oxidation, if the samples come in contact with air. In order to overcome these major limitations, a thin layer of indium-tin-oxide was deposited by ion-sputtering on gold-decorated HeLa cells and neurons. Indium-tin-oxide was able to provide stable electrical conductivity and preservation of the BSE signal coming from the gold-conjugated markers. © 2015 Wiley Periodicals, Inc.

  7. Imaging of acute myocardial infarction in pigs with Indium-111 monoclonal antimyosin scintigraphy and MRI

    International Nuclear Information System (INIS)

    Kate, C.I.; Kroonenburgh, M.J. van; Schipperheyn, J.J.; Doornbos, J.; Hoedemaeker, P.J.; Maes, A.; Nat, K.H. van der; Camps, J.A.; Huysmans, H.A.; Pauwels, E.K.

    1990-01-01

    Indium-111 antimyosin F(ab')2 was used in a series of scintigraphic studies on experimentally induced myocardial infarctions in pigs. Antimyosin distribution recorded by planar images of in vivo pigs and by single photon emission computed tomography (SPECT) of excised hearts delineated areas of myocardial necrosis if infarct volume exceeded 3.3 cm3. Scintigraphic images were compared with magnetic resonance images (MRI) obtained from excised hearts and with photographs of slices of the hearts. Infarct size and localization determined with antimyosin were compared. The MR images, with or without gadolinium-DTPA (Gd-DTPA), of the in vivo pigs were all false-negative; some myocardial wall thinning and high bloodpool signals were visible. Results show that both the antimyosin and the MR technique are specific methods for the visualization of induced myocardial necrosis in this animal model. However, the use of antimyosin is limited to a period ranging from 24 to 72 hours after infarction

  8. In-111-labeled leukocyte imaging: false-positive study due to acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Fisher, M.F.; Rudd, T.G.

    1983-01-01

    A case is reported in which In-111-labeled leukocytes accumulated in the left colon on a 24-hr delayed image. This was found to be secondary to an upper gastrointestinal bleed in progress at the time of injection of the radiolabeled leukocytes

  9. Detection of occult abscesses with 111In-labeled leukocytes

    International Nuclear Information System (INIS)

    Martin, W.R.; Gurevich, N.; Goris, M.L.; McDougall, I.R.

    1979-01-01

    Clinicians are frequently faced with the problem of a patient in whom they suspect an occult abscess. In such a situation, there may be no clinical signs to localize the site of the abscess and often extensive investigations do not provide additional useful information. This report illustrates the efficacy of autologous leukocytes labeled with 111 In oxine in detecting the site and extent of occult abscesses in two patients. The technique of in vitro lebeling of leukocytes is simple and has been mastered by all of our nuclear medicine technologists

  10. Indium-111-labeled white blood cells in the detection of osteomyelitis complicated by a pre-existing condition

    International Nuclear Information System (INIS)

    McCarthy, K.; Velchik, M.G.; Alavi, A.; Mandell, G.A.; Esterhai, J.L.; Goll, S.

    1988-01-01

    Forty-six patients (23M, 23F) ranging in age from 19 to 79 yr with a clinical history of a nonunion fracture, surgery, diabetes or a soft-tissue infection were studied with [ 111 In]oxine WBCs to detect osteomyelitis. There were 27 true-positive, nine true-negative, two false-positive and one false-negative. The false-positives and the false-negative occurred in patients with soft-tissue infections overlying the area of interest. All diagnoses were confirmed by intraoperative bone biopsies and cultures. Bone biopsy and scan were performed within 2 days of each other in 39 patients. The overall sensitivity was 97% (27/28), specificity, 82% (9/11) and the diagnostic accuracy, 92% (36/39). The remaining seven patients had negative [ 111 In]WBC scans several months after positive bone biopsies and definite antibiotic treatment. This suggests that [In]WBC scans become negative after appropriate therapy is undertaken. Interobserver data was obtained from four nuclear physicians of varying experience blinded to clinical information. A high degree of agreement was found in over 90% of the cases. This study demonstrates the utility of [ 111 In]WBC scans in the diagnosis and follow-up of complicated osteomyelitis and a high level of interobserver agreement in scan interpretation

  11. Comparison of simultaneous [sup 99m]Tc-HMPAO and [sup 111]In oxine labelled white cell scans in the assessment of inflammatory bowel disease

    Energy Technology Data Exchange (ETDEWEB)

    Allan, R.A.; Bassingham, S.; Lazarus, C.; Clarke, S.E.M.; Fogelman, I. (Guy' s Hospital, London (United Kingdom). Dept. of Nuclear Medicine); Sladen, G.E. (Guy' s Hospital, London (United Kingdom). Dept. of Gastroenterology)

    1993-03-01

    Forty-seven patients, 29 with chronic inflammatory bowel disease (IBD) and 18 with presumed irritable bowel syndrome, including one with uncomplicated diverticular disease, were studied with simultaneous technetium-99m hexamethylpropylene amine oxime and indium-III oxine labelled leucocyte scans performed at 1, 3 and 24 h. Twenty-seven patients with IBD had active disease as judged by clinical and laboratory criteria and all of these had positive scans with both agents. No false positive studies were obtained. The 1-h [sup 99m]Tc-HMPAO WBC scans showed the same distribution to disease as the 3-h [sup 111]-In WBC scans, with no difference in intensity (P<0.92); they showed more extensive disease (P<0.02) and more intense uptake (P<0.001) than did the 1-h [sup 111]-In scans. The 3-h [sup 99m]Tc-HMPAO WBC scans showed more extensive disease (P<0.002), with greater intensity (P<0.0005), than did the 3-h [sup 111]In WBC scans. Physiological bowel activity on 3-h [sup 99m]Tc-HMPAO WBC scans was present in 12 patients but was faint and did not interfere with assessment of disease extent and activity. It is concluded that in terms of isotope availability, radiation dosimetry and image quality, [sup 99m]Tc-HMPAO is the agent of choice in detecting active IBD, with localization of disease possible at 1-h after re-injection and optimal resolution and definition of disease extent at 3 h. A negative scan reliably excludes active disease. (orig.).

  12. Leucocytes labelled with In-111-oxine in acute inflammatory processes

    International Nuclear Information System (INIS)

    Herranz, R.; Lomena, F.; Fernandez, R.M.; Del Rio, L.; Piera, C.; Vida, F.; Setoain, J.

    1982-01-01

    We used autologous leucocytes labelled with In-111-Oxine to diagnose inflammatory processes, located or scattered, in 60 patients. In 46 there was suspected located infection focus. Gammagraphy was abnormal in 38 cases (83%), 28 abdominally located (87%), 5 thorax located (71%) and 5 of several locations. In other 14 cases there was clinic suspicion of infection without located septic focus. In 5 of them gammagraphy was interpreted as positive but only in 3 patients it was found abdominal located abscess. The two other cases are considered as false positive ones. In the 9 remaining, with negative gammagraphy there was no clinic confirmation nor other diagnostic methods of abscess existence. In this paper we checked high sensitivity of leucocytes In-111-Oxine to diagnose and locate infectious focuses. In our casuistry there was only a false negative and two false positive ones

  13. Preparation of lyophilized kit of HYNIC-[Tyr3]-Octreotate and labelling studies with 99m-Technetium

    International Nuclear Information System (INIS)

    Melo, Ivani Bortoleti

    2008-01-01

    The development of radiolabeled molecules with high specificity for an organ ar tumor has been contributed to the precise diagnostic in nuclear medicine. Somatostatin labeled derivatives constitutes a particular example of labeled peptide applied in the localization of neuroendocrine tumors. Nowadays, the 111 In DTPA-octreotide is the radiopharmaceutical applied in diagnostic procedures for the visualization of tumors with high expression of somatostatin receptors. However, the 111-indium is a radionuclide that presents some limitations related to availability (cyclotron production), half-life (67 hours) and the emission of medium energy photons (171 keV e 245 keV), not favorable to the acquisition of images in SPECT (Single Photon Emission Computed Tomography). The favorable physical properties of the 99m -technetium ( 99m Tc) make this radionuclide the more favorable to substitute the 111-indium on peptide labeling procedures. This work studied the preparation and labeling of a lyophilized kit of HYNIC-Tyr 3 -octreotate (HYNIC-octreotate) with 99m Tc, base on previously described procedures and using tricine and EDDA (ethylendiaminediacetic acid) as coligands. It was studied the labeling parameters (incubation time, temperature, volume and perthecnetate activity) and the stability of the lyophilized preparation. Additionally, it was studied the influence of the pre-freezing using liquid nitrogen in the stability of the lyophilized preparation, as well as the influence of manitol in the labeling yield and biological distribution of the complex. The stability studies showed that the lyophilization using liquid nitrogen pre-freezing resulted in a lyophilized preparation with stability over 4 month when stored under refrigeration. The stability of the lyophilized preparation obtained without liquid nitrogen pre-freezing was similar.The labeling studies determined the best labeling conditions, resulting in a radiochemical yield superior than 90%. The use of manitol in

  14. Kit for the preparation of 111In-labeled pertuzumab injection for imaging response of HER2-positive breast cancer to trastuzumab (Herceptin)

    International Nuclear Information System (INIS)

    Lam, Karen; Scollard, Deborah A.; Chan, Conrad; Levine, Mark N.; Reilly, Raymond M.

    2015-01-01

    We previously reported that 111 In-labeled pertuzumab imaged trastuzumab (Herceptin)-mediated changes in HER2 expression preclinically in breast cancer tumors. To advance 111 In-labeled pertuzumab to a Phase I/II clinical trial, a kit was designed for preparing this agent in a form suitable for human administration. Unit-dose kits containing pertuzumab modified with 2-(4-isothiocyanatobenzyl)-diethylenetriaminepentaacetic acid (BzDTPA) were prepared that labeled to high efficiency (>90%) with 111 In and met specifications for pharmaceutical quality. The kits were stable for 4 months and the final radiopharmaceutical was stable for 24 h. Imaging studies demonstrated high and specific uptake in HER2-positive tumors in mice using this clinical kit formulation. - Highlights: • Kits for preparing 111 In-BzDTPA-pertuzumab were prepared which met specifications for pharmaceutical quality. • The kits were stable for at least 4 months and the final radiopharmaceutical was stable for 24 h when stored at 2–8 °C. • High labeling efficiency (>90%) of the kits was achieved with 111 In. • 111 In-BzDTPA-pertuzumab exhibited stability in human plasma. • Biodistribution and microSPECT imaging showed specific targeting of HER2-positive tumors in mice using the kit formulation

  15. Further studies on the relationship between platelet buoyant density and platelet age

    International Nuclear Information System (INIS)

    Boneu, B.; Vigoni, F.; Boneu, A.; Caranobe, C.; Sie, P.

    1982-01-01

    The relationship between platelet buoyant density and platelet age was investigated in eight human subjects submitted to an autologous chromium labeled platelet survival study. Platelets were isolated after isopycnic centrifugation using eight discontinuous isoosmotic stractan gradients (five subjects), or various continuous and linear isoosmolar gradients (three subjects). A paradoxical radioactivity enrichment of the dense platelets and a premature loss of radioactivity in the light platelets were observed. These results are explained by a shift of the radioactivity distribution curve toward higher densities during the 3-4 days after platelet injection, while the standard deviation of the distribution was conserved throughout the platelet life span. These results suggest that young platelets are heterogeneous and slightly less dense than the total platelet population

  16. Comparative orbital scintigraphy with technetium-99m-P829, indium-111-DOTA-Lanreotide and DOTA-Tyr3-octreotide in Graves disease

    International Nuclear Information System (INIS)

    Burggasser, G.; Hauff, W.; Thaler, A.; Hurtl, I.; Greifeneder, M.; Virgolini, I.; Traub, T.; Dudczak, R.; Angelberger, P.

    2002-01-01

    Aim: Receptors (R) for somatostatin (SST) are expressed on various tumor cells as well as activated leukocytes and other lymphoproliferative and immune cells. Our previous data have shown that various SST analogs including 111 In-OctreoScan, 111 In-DOTA-Lanreotide (DLAN), 111 In-DOTA-Tyr3-Octreotide (DTOCT) and 99m Tc-P829 bind with high affinity onto many different types of tumor cells as well as to leukocytes via hSSTR target receptors. We have evaluated the orbital uptake of these tracers in patients with active and inactive thyroid-associated orbitopathy. Material and Methods: Clinical grade of the orbital disease was documented in all patients (n=90) by the NOSPECS classification, the clinical activity score (CAS) as well as the supra nasal index (SNI) measured by standardized echography. 99m Tc-P829 scintigraphy (740 MBq) or scintigraphy with one of the 111 In-labeled SST analogs (150 MBq) was performed in patients with thyroid-associated orbitopathy (duration of the disease: 1 - 360 months). In patients undergoing 99m Tc-P829 scintigraphy, SPECT (360 deg.) and planar studies were completed within 3 h post injection, whereas most patients undergoing scintigraphy with 111 In-labeled SST analogs also had a 24 h image acquisition. Orbital (O) regions of interest (ROIs) were opposed to temporo-parietal (TP) and occipital (OCC) ROIs and the O/TP and O/OCC ratios were calculated. Uptake ratios in Graves disease were compared to orbital data calculated from cancer patients without eye disease. Results: Compared to clinical data, a significant correlation was found only for CAS (p 99m Tc-P829 images (three independent observers) despite of somewhat lower uptake both for O/TP as well as O/OCC uptake ratios. 111 In-DLAN and 111 In-DTOCT biokinetics were comparable in Graves disease patients showing a rapid blood clearance and visualization of the orbit within minutes of injection. In patients without active disease (O/(TP+OCC) / 2 ratio: 1.20 +/- 0.09) as well as in

  17. Data Evaluation Acquired Talys 1.0 Code to Produce 111In from Various Accelerator-Based Reactions

    Science.gov (United States)

    Alipoor, Zahra; Gholamzadeh, Zohreh; Sadeghi, Mahdi; Seyyedi, Solaleh; Aref, Morteza

    The Indium-111 physical-decay parameters as a β-emitter radionuclide show some potential for radiodiagnostic and radiotherapeutic purposes. Medical investigators have shown that 111In is an important radionuclide for locating and imaging certain tumors, visualization of the lymphatic system and thousands of labeling reactions have been suggested. The TALYS 1.0 code was used here to calculate excitation functions of 112/114-118Sn+p, 110Cd+3He, 109Ag+3He, 111-114Cd+p, 110/111Cd+d, 109Ag+α to produce 111In using low and medium energy accelerators. Calculations were performed up to 200 MeV. Appropriate target thicknesses have been assumed based on energy loss calculations with the SRIM code. Theoretical integral yields for all the latter reactions were calculated. The TALYS 1.0 code predicts that the production of a few curies of 111In is feasible using a target of isotopically highly enriched 112Cd and a proton energy between 12 and 25 MeV with a production rate as 248.97 MBq·μA-1 · h-1. Minimum impurities shall be produced during the proton irradiation of an enriched 111Cd target yielding a production rate for 111In of 67.52 MBq· μA-1 · h-1.

  18. The acetabulum: A prospective study of three-phase bone and indium white blood cell scintigraphy following porous-coated hip arthroplasty

    International Nuclear Information System (INIS)

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Anderson, J.H.; Callaghan, J.J.

    1990-01-01

    Although few studies address the use of three-phase bone scanning (TPBS) and indium-111-labeled white blood cell scintigraphy ( 111 In-WBC) in hip arthroplasty utilizing a porous-coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen with the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous-coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and 111I n-WBC at approximately 7 days, and 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the acetabulum. All 25 prostheses (144 of 144 scans) demonstrated increased uptake on the bone-phase images. Although this activity decreased with time, 76% had persistent uptake at 24 mo. Twenty-three of 25 prostheses (126 of 140 scans) showed increased uptake on 111 In-WBC scintigraphy, invariably decreasing with time, but with 37% having significant uptake at 24 mo. Scintigraphic patterns in the uncomplicated porous-coated hip arthroplasty patient appear to differ from patterns described in cemented prostheses

  19. Preoperative clinical radioimmunodetection of pancreatic cancer by 111In-labeled chimeric monoclonal antibody Nd2

    International Nuclear Information System (INIS)

    Sawada, Tetsuji; Nishihara, Tamahiro; Yamamoto, Atsushi

    1999-01-01

    The present study was carried out with the purpose of evaluating the clinical usefulness of radioimmunodetection (RAID) with 111 In-labeled murine/human chimeric monoclonal antibody, Nd2 (c-Nd2) in patients with pancreatic cancer. Nineteen patients suspected to have pancreatic cancer were administered intravenously 74 MBq/2 mg 111 In-labeled c-Nd2 in 100 ml of saline containing 2% albumin over 30 min. A scintigram was obtained on the 3rd day after infusion by using single photon emission computed tomography (SPECT) imaging. Of the 14 patients finally diagnosed as having pancreatic cancer on the basis of surgical specimens or progress of disease, specific focal uptake at the site of the tumor was detected in 12 (true positive cases), representing a sensitivity of 85.7% (12/14), and liver metastasis was found in one case with metastasis. Of the 5 patients diagnosed with tumor-forming pancreatitis (TFP), 4 patients demonstrated true negative imaging, but one patient whose tumor demonstrated interesting findings in histology and immunostaining, showed false positive imaging. Of patients investigated for human anti-chimeric antibody (HACA) response, none showed HACA response, and no allergic reaction was seen in any of the patients administered c-Nd2. These results suggest that RAID with 111 In-labeled c-Nd2 is useful for differential preoperative diagnosis between invasive pancreatic cancer and TFP. (author)

  20. Scintigraphic detection of metastatic melanoma using indium 111/DTPA conjugated anti-gp240 antibody (ZME-018)

    International Nuclear Information System (INIS)

    Kirkwood, J.M.; Neumann, R.D.; Zoghbi, S.S.; Ernstoff, M.S.; Cornelius, E.A.; Shaw, C.; Ziyadeh, T.; Fine, J.A.; Unger, M.W.

    1987-01-01

    We evaluated the toxicity, pharmacokinetics, and localization of a monoclonal IgG2 alpha murine anti-human melanoma (gp240) antibody (ZME-018) that recognizes a tumor-associated cell surface glycoprotein of 240,000 molecular weight present in most melanomas. The antibody was conjugated with DTPA (diethylenetriamine pentaacetic acid) and labeled by chelation of 111 In. One mg of antibody labeled with 5 mCi of 111 In was infused, together with 0 to 40 mg of cold carrier ZME-018. The blood clearance, urinary excretion, and in vivo localization were determined in 26 patients. Scintigraphic images were obtained at 24 hours and 72 hours in all patients. Mild toxicity occurred in one patient. The half-time clearance of labeled monoclonal murine antibody (MoAb) from the blood increased from 16.1 hours at an antibody dose of 1 mg to 35.9 hours at 40 mg. Males showed faster clearance from the blood than did females or a single castrated male, perhaps due to selective concentration of antibody in the testes. Nonspecific uptake in liver, spleen, bone marrow, and intestine was seen in all patients. The percentage of known metastatic foci detected increased with the total dosage of antibody, from 23% at doses less than or equal to 5 mg, to 65%, 87% and 78% for 10, 20, and 40 mg, respectively. We conclude that at doses of greater than or equal to 10 mg, ZME-018 is a safe and potentially useful agent for the scintigraphic detection of metastatic malignant melanoma

  1. Immunopathology of thrombocytopenia in experimental malaria.

    Science.gov (United States)

    Grau, G E; Piguet, P F; Gretener, D; Vesin, C; Lambert, P H

    1988-12-01

    An early thrombocytopenia was observed in CBA mice during acute infection with Plasmodium berghei. This was associated with an increase in bone marrow megakaryocytes and a reduction of normal syngeneic 111Indium-labelled platelet life span. Malaria-induced thrombocytopenia was thus considered to be the result of increased peripheral platelet destruction rather than central hypoproduction. The occurrence of thrombocytopenia was modulated by T-cell depletion. Indeed, thymectomized, irradiated or anti-CD4 monoclonal antibody-treated mice failed to develop thrombocytopenia, although they were infected to the same extent. Conversely, a significant thrombocytopenia was observed in thymectomized mice reconstituted with CD4+ T cells. During the course of infection, a significant inverse correlation was found between platelet counts and platelet-associated IgG. Normal mice passively transferred with serum from syngeneic malaria-infected mice developed thrombocytopenia. The possibility to raise monoclonal anti-platelet antibodies from P. berghei-infected animals further suggested a role for an antibody-mediated platelet destruction during acute murine malaria infection. These results indicate that in murine malaria, thrombocytopenia is mediated by immune mechanisms and that CD4+ T cells might be significantly involved.

  2. Synthesis of indium-labeled antibody-chelate conjugates for radioassays

    Energy Technology Data Exchange (ETDEWEB)

    Gokce, A; Nakamura, R M; Tubis, M; Wolf, W

    1982-01-01

    A method has been developed to achieve rapid and reproducible complexation of indium to transferrin at pH 7.4. The system consists of nitrilotriacetic acid (NTA) as the intermediate carrier ligand, whose function is to allow the /sup 113/m In ion, in a solution in Tris buffer, pH 7.4, to be transferred rapidly to the specific binding sites on transferrin. Just as in the case of iron, this complexation requires the presence of a synergistic ion such as bicarbonate. The present system can be used to allow the binding of /sup 113/mIn to transferrin when coupled to an antibody. This method has been tested by studying the conjugation of an antibody, the IgG fraction of goat anti-rabbit-IgG, with either transferrin or desferoxamine, using glutaraldehyde as the coupling agent. Optimization in terms of total protein concentration and glutaraldehyde levels lead to products where the specific metal binding capacity of the transferrin moiety remains unchanged, and where the antibody retains 70% of its antigenic activity. The present system can be considered an extension of the ELISA techniques and can be used to determine, by a terminal /sup 113/mIn labeling technique, the level of specific binding of an antibody to its antigen.

  3. The clinical use of platelet scintigraphy with 111-In-oxine

    International Nuclear Information System (INIS)

    Kessler, C.; Reuther, R.; Berentelg, J.; Kimmig, B.

    1983-01-01

    Platelet scintigraphy was performed on 62 patients with cerebral ischaemia. Pathological scintigraphic images were obtained in 29 of the 62 patients. In 79.3% of these 29 patients the scan was abnormal in the vessel clinically affected. Platelet scintigraphy was abnormal in 21 of 34 patients with normal angiogram or only slight atherosclerosis. In patients undergoing antiplatelet therapy, platelet scintigraphy was less often positive than in untreated patients. It is suggested that platelet scintigraphy could be an appropriate technique for detecting small mural thrombi of the carotid artery, which are the source of arterio-arterial emboli, and for controlling the efficiency of antiplatelet therapy. (orig.) [de

  4. A comparison of 111In-labelled polymer beads and 99mTc-Sn-colloid as solid food and semi-solid food tracers for scintigraphic gastric emptying studies

    International Nuclear Information System (INIS)

    Dormehl, I.C.; Du Plessis, M.; Maree, M.; Pilloy, W.J.

    1986-01-01

    In order to establish the efficacy of labelling a solid meal and a semi-solid meal with either 111 In-labelled polymer beads or 99m Tc-tin colloid beagle dogs were fed variously labelled meals of different consistencies and then monitored by scintigraphy for gastric motility patterns. The labelling with each tracer was either performed by thoroughly mixing it into the food before cooking, or alternatively by surface labelling after the food had been cooked. For the 99m Tc-Sn-colloid tracer no difference was found in the measured gastric emptying times resulting from either pre-cooking labelling or surface labelling of the meals. Cooking the tracer together with the ingredients does however seem to promote a firm entrapment of the 111 In-polymer beads into a solid protein, and in this manner the 111 In-labelled resin appears to be a reliable solid food tracer. Surface labelling with 111 In-polymer beads of a solid meal with a smooth texture fails totally and the tracer empties with the liquid phase. (orig.) [de

  5. Granulocyte-platelet interactions and platelet fibrinogen receptor exposure

    International Nuclear Information System (INIS)

    Kornecki, E.; Ehrlich, Y.H.; Egbring, R.; Gramse, M.; Seitz, R.; Eckardt, A.; Lukasiewicz, H.; Niewiarowski, S.

    1988-01-01

    The authors have examined the interaction of human granulocyte elastase with human platelets. Incubation of human platelets with human granulocyte elastase exposed active fibrinogen-binding sites as evidenced by 125 I-labeled fibrinogen binding and spontaneous fibrinogen-induced platelet aggregation. The aggregation of platelets by fibrinogen occurred at low concentrations of human granulocyte elastase. Platelets pretreated with human granulocyte elastase exposed an average of 10,500 fibrinogen-binding sites per platelet, i.e., about one-third the number of binding sites exposed by optimal concentrations of ADP. With the use of a polyclonal antiplatelet membrane antibody, the glycoproteins IIb (GPIIb), IIIa (GPIIIa), and a 60,000-Da (60 kDa) protein (66 kDa in a reduced system) derived from GPIIIa were immunoprecipitated from the surface of detergent extracts of human 125 I-radiolabeled platelets pretreated with increasing concentrations of human granulocyte elastase. They conclude that (1) the proteolytic action of human granulocyte elastase on platelet GPIIIa results in the formation of two major hydrolytic products, and (2) human granulocyte elastase exposes active fibrongen-binding sites associated with the GPIIb/GPIIIa complex, resulting in direct platelet aggregation by fibrinogen

  6. Monitoring of a new approach of immunotherapy with allogenic 111In-labelled NK cells in patients with renal cell carcinoma

    International Nuclear Information System (INIS)

    Meller, Birgit; Lauer, Isabel; Schelper, Lutz F.; Hof, Katharina von; Richter, Eckart; Baehre, Manfred; Frohn, Christoph; Brand, Joerg-Matthias; Kirchner, Holger

    2004-01-01

    The transfusion of allogenic, in vitro expanded natural killer cells (NKC) is a novel therapy option in oncology. To date, however, the biodistribution and kinetics of allogenic NKC have not been investigated. Therefore, in this study three patients with renal cell carcinoma received 3-7 x 10 8 NKC labelled with indium-111 oxine with a tenfold excess of unlabelled cells during NKC therapy. Whole-body scintigrams were obtained (0.5-144 h) in the anterior and posterior views. Scintigrams were analysed using a region of interest technique, and single-photon emission tomography (SPET) studies of the abdomen were performed. Results were compared to those obtained with polymerase chain reaction (PCR) of the peripheral blood (determination of foreign DNA, nested PCR, limit of detection 0.01%). Shortly after transfusion of NKC, more than 50% of the activity was accumulated in the lungs. We observed redistribution effects from lungs to liver, spleen and bone marrow. No significant loss of activity could be detected. In two of four large metastases, tracer accumulation could be proven by SPET. As confirmed by scintigrams and PCR, the fraction of circulating transfused cells was low at all times. Long-term activity retention might be caused either by survival of the allogenic cells, as confirmed by PCR (up to 3 days p.i.), or by phagocytosis of labelled cellular fragments. However, PCR data and uptake in metastases indicated long survival of a portion of allogenic NKC. Such long survival and low retention of the cells in the lung are requirements for an effective immunotherapeutic approach. (orig.)

  7. A brief history of cell labelling

    International Nuclear Information System (INIS)

    Peters, A.M.

    2005-01-01

    The term cell labelling is usually used in the context of labelled leukocytes for imaging inflammation and labelled platelets for imaging thrombosis. Erythrocyte labelling for in vitro measurements of red cell life span, in vivo measurements of splenic red cell pooling, radionuclide ventriculography and imaging sites of bleeding has developed rather separately and has a different history. Labelled platelets and leukocytes were originally developed for cell kinetic studies. Since the current-day applications of labelled platelets and leukocytes depend on a clear understanding of cell kinetics, these classical studies are important and relevant to the history of cell labelling

  8. Usefulness of bone marrow magnetic resonance imaging and indium-111-chloride bone marrow scintigraphy in patients with various hematological diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Yutaka; Umekawa, Tsunekazu; Chikayama, Satoshi [Osaka General Hospital of West Japan Railway Compapy (Japan)] [and others

    1995-03-01

    This study investigated the ability of magnetic resonance (MR) imaging and indium-111 chloride (In-111) scintigraphy to assess bone marrow in various hematological lesions. The subjects were 7 with aplastic anemia (AA), 4 with myelodysplastic syndrome (MDS), 3 with polycythemia (PC), 3 with essential thrombocythemia (ET), 2 with multiple myeloma (MM), 2 with monoclonal gammopathy of undetermined significance (MGUS), 3 with idiopathic thrombocytopenic purpura (ITP), one with acute lymphocytic leukemia (ALL), and one with secondary anemia due to chronic inflammation (SA). Bone marrow cellularity was assessed on MR images and both uptake and tissue distribution were assessed on In-111 scintigraphy. Hypo-cellularity was seen in all AA patients, but not seen in any other patient in each group. On the other hand, hyper-cellularity was seen in 3 MDS, one PC, all 3 ET, one ALL, and one SA patients. In the group of MM, the vertebral body was seen as heterogenous signal intensity on MR images. Bone marrow was seen as iso-intensity in one MDS, 2 PC, all 2 MGUS, and all 3 ITP patients. In-111 scintigraphy showed decrease or disappearance of tracer uptake and decreased tissue distribution in all 7 AA, one MDS, one PC, and one ALL patients. Increased tracer uptake and enlarged tissue distribution were seen in one MDS, one PC, and one SA patients. One MDS, one ET, all 2 MM, all 2 MGUS, all 3 ITP patients had tracer uptake and tissue distribution that were equal to those in the normal tissues. Since MR imaging and In-111 scintigraphy provided qualitatively different information, the combination of both modalities would contribute to the understanding of bone marrow condition in hematopoietic diseases. (N.K.).

  9. In vivo assessment of 111In-labeled hematoporphyrin derivative in breast tumor-bearing animals

    International Nuclear Information System (INIS)

    Wong, D.W.; Mandal, Ashis; Brown, Jerry; Reese, I.C.; Siegler, Richard; Hyman, Shigeyo

    1989-01-01

    The biological behavior of 111 In-labeled HPD has been investigated in tumor-bearing animals. Mice mammary adenocarcinomas and 7,12-dimethylbenz(a)anthracine induced breast tumors in Sprague-Dawley female rats were clearly visualized by 111 In-HPD nuclear scintigraphy. Optimal scans were obtained after a 48 h delay. In normal and tumor-bearing animals, the highest uptake of 111 In-HPD 72 h post-injection was found in the liver, the spleen and the kidneys. Depending on the size and the extent of necrosis, the uptake of 111 In-HPD by malignant breast tumors varied from 2.5% injected dose (ID) in mice to 1% ID in rats. Benign breast tumor uptake of 111 In-HPD was less than 1% ID. No significant amount of the radiopharmaceutical was found in pulmonary abscesses and abdominal cysts. Scintigrams of these infectious or inflammatory lesions were normal. Malignant tumor to blood, heart and lung ratios averaged 50:1, 10:1 and 3:1 respectively. Tumor to brain ratio ranged from 72 to 444:1. (author)

  10. In vitro effects on Indium-111-Oxine labeled leukocytes functions of N-etilmycin

    International Nuclear Information System (INIS)

    Iacovo, R.D.; Perna, M.; Esposito, G.; Polese, C.; Frizzi, L.

    1985-01-01

    In order to study in vitro chemotaxis, phagocytosis and bactericydal efficiencies of granulocytes (PMN) and monocytes (Mo) of cancer patients with solid tumours, the authors have undertaken the evaluation of a method of measuring PMN and Mo chemotaxis with modified Boyden chambers, using In-111-oxine. The tests were performed in order to evaluate the interference of N-etilmycin with leukocyte functions, a currently fashionable antibiotic used in the treatment of gram-negative infections. The results both compare well with the visual method and are objective. Cancer patients, disease-free for a minimum of one year, were compared and evidenced normal chemotaxis and normal controls. No difference between the two groups was found (20.46% of those tested). The addition of N-etilmy-cin (6μg/ml) to PMN and Mo further decreased the chemotaxis from 20.46% to 16.07% (t=2.81, P=0.0102). The addition of 30μg/ml further decreased the chemotaxis from the mean control values to 5.925% (t=4.55,P 1%). The use of N-etilmycin in disease-free cancer patients should be avoided in the possible event of tumour enhancement

  11. 21 CFR 111.425 - What requirements apply to a packaged and labeled dietary supplement that is rejected for...

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What requirements apply to a packaged and labeled dietary supplement that is rejected for distribution? 111.425 Section 111.425 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD...

  12. The effect of various antibiotics on the labelling efficiency of human white blood cells with 111In-oxine

    International Nuclear Information System (INIS)

    Sinzinger, Helmut; Granegger, Susanne

    1988-01-01

    Earlier clinical studies revealed that in patients suffering from chronic osteomyelitis undergoing antibiotic therapy the white blood cell scanning missed the right diagnosis in 40% of cases, whereas all the acute untreated cases were imaged correctly. Thus, it was suspected that an impaired labelling efficiency and white blood cell function might have been causative. Retrospective analysis of labelling efficiency exhibited no difference between patients on antibiotics and those not on antibiotics. Prospective cellular viability testing in 81 patients, 71 of whom were on various antibiotics, using latex particles (phagocytosis) and the Trypan blue exclusion test, did not reveal any different function behaviour either. Examining the labelling efficiency (after 111 In-oxine and 111 In-oxine-sulphate labelling), recovery, half-life and viability of white blood cells of 107 patients undergoing therapy with various antibiotics as compared to controls, it becomes evident that the antibiotic therapy is not causative of the clinical difference observed. (author)

  13. In vitro and in vivo properties of human/mouse chimeric monoclonal antibody specific for common acute lymphocytic leukemia antigen

    International Nuclear Information System (INIS)

    Saga, T.; Endo, K.; Koizumi, M.; Kawamura, Y.; Watanabe, Y.; Konishi, J.; Ueda, R.; Nishimura, Y.; Yokoyama, M.; Watanabe, T.

    1990-01-01

    A human/mouse chimeric monoclonal antibody specific for a common acute lymphocytic leukemia antigen was efficiently obtained by ligating human heavy-chain enhancer element to the chimeric heavy- and light-chain genes. Cell binding and competitive inhibition assays of both radioiodine and indium-111- (111In) labeled chimeric antibodies demonstrated in vitro immunoreactivity identical with that of the parental murine monoclonal antibodies. The biodistribution of the radiolabeled chimeric antibody in tumor-bearing nude mice was similar to that of the parental murine antibody. Tumor accumulation of radioiodinated parental and chimeric antibodies was lower than that of 111 In-labeled antibodies, probably because of dehalogenation of the radioiodinated antibodies. Indium-111-labeled chimeric antibody clearly visualized xenografted tumor. These results suggest that a human/mouse chimeric antibody can be labeled with 111 In and radioiodine without the loss of its immunoreactivity, and that chimeric antibody localizes in vivo in the same way as the parental murine antibody

  14. Chronic bacterial osteomyelitis: prospective comparison of 18F-FDG imaging with a dual-head coincidence camera and 111In-labelled autologous leucocyte scintigraphy

    International Nuclear Information System (INIS)

    Meller, J.; Siefker, U.; Lehmann, K.; Meyer, I.; Schreiber, K.; Altenvoerde, G.; Becker, W.; Liersch, T.

    2002-01-01

    Indium-111-labelled white blood cells ( 111 In-WBCs) are currently considered the tracer of choice in the diagnostic work-up of suspected active chronic osteomyelitis (COM). Previous studies in a limited number of patients, performed with dedicated PET systems, have shown that [ 18 F]2'-deoxy-2-fluoro-D-glucose (FDG) imaging may offer at least similar diagnostic accuracy. The aim of this prospective study was to compare FDG imaging with a dual-head coincidence camera (DHCC) and 111 In-WBC imaging in patients with suspected COM. Thirty consecutive non-diabetic patients with possible COM underwent combined skeletal scintigraphy (30/30 patients), 111 In-WBC imaging (28/30 patients) and FDG-PET with a DHCC (30/30 patients). During diagnostic work-up, COM was proven in 11/36 regions of suspected skeletal infection and subsequently excluded in 25/36 regions. In addition, soft tissue infection was present in five patients and septic arthritis in three. 111 In-WBC imaging in 28 patients was true positive in 2/11 regions with proven COM and true negative in 21/23 regions without further evidence of COM. False-positive results occurred in two regions and false-negative results in nine regions suspected for COM. Most of the false-negative results (7/9) occurred in the central skeleton. If the analysis was restricted to the 18 regions with available histology (n=17) or culture (n=1), 111 In-WBC imaging was true positive in 2/18 regions, true negative in 8/18 regions, false negative in 7/18 regions and false positive in 1/18 regions. FDG-DHCC imaging was true positive in 11/11 regions with proven COM and true negative in 23/25 regions without further evidence of COM. False-positive results occurred in two regions. If the analysis was restricted to the 19 regions with available histology (n=18) or culture (n=1), FDG-DHCC imaging was true positive in 9/9 regions with proven COM and true negative in 10/10 regions without further evidence of COM. It is concluded that FDG

  15. Radiolabeled blood cells: radiation dosimetry and significance

    International Nuclear Information System (INIS)

    Thakur, M.L.

    1986-01-01

    Over the past few years blood cells labeled with In-111 have become increasingly useful in clinical diagnosis and biomedical research. Indium-111 by the virtue of its physical characteristics and ability to bind to cell cytoplasmic components, provides an excellent cell tracer and thereby, allows investigators to monitor in vivo cell distribution by external imaging and help determine a course of regimen in treating life threatening diseases. Due to natural phenomena such as margination, blood pool, and reticuloendothelial cell activity, in the normal state, depending upon the cell type and the quality of cell preparations, 30%-50% of the administered radioactivity is immediately distributed in the liver, spleen and bone marrow. Over a period of time the radioactivity in these organs slightly increases and decays with a physical half-life of In-111. The resulting radiation dose to these organs ranges between 1-25 rads/mCi In-111 administered. The authors have developed a new In-111 labeling technique which preserves platelet ultrastructure and shown that human lymphocytes labeled with In-111 in mixed leukocytes preparations a) are only 0.003% of the total -body lymphocytes population and b) are killed. The consequence if any may be considered insignificant, particularly because 5.6% metaphases from normal men and 6.5% metaphases from normal women in the US have at least one chromosome aberration. Calculations have shown that the risk of fatal hematological malignancy, over a 30 year period, in recipients of 100 million lymphocytes labeled with 100 μCi In-111 is 1/million patients studied. This risk is less than 0.025% of the 1981 spontaneous cancer patient rate in the country. 32 references, 10 tables

  16. Comparison of /sup 111/In-labelled polymer beads and /sup 99/mTc-Sn-colloid as solid food and semi-solid food tracers for scintigraphic gastric emptying studies

    Energy Technology Data Exchange (ETDEWEB)

    Dormehl, I.C.; Du Plessis, M.; Maree, M.; Pilloy, W.J.

    1986-04-01

    In order to establish the efficacy of labelling a solid meal and a semi-solid meal with either /sup 111/In-labelled polymer beads or /sup 99m/Tc-tin colloid beagle dogs were fed variously labelled meals of different consistencies and then monitored by scintigraphy for gastric motility patterns. The labelling with each tracer was either performed by thoroughly mixing it into the food before cooking, or alternatively by surface labelling after the food had been cooked. For the /sup 99m/Tc-Sn-colloid tracer no difference was found in the measured gastric emptying times resulting from either pre-cooking labelling or surface labelling of the meals. Cooking the tracer together with the ingredients does however seem to promote a firm entrapment of the /sup 111/In-polymer beads into a solid protein, and in this manner the /sup 111/In-labelled resin appears to be a reliable solid food tracer. Surface labelling with /sup 111/In-polymer beads of a solid meal with a smooth texture fails totally and the tracer empties with the liquid phase.

  17. Chapter 19. Blood and bone marrow. C. Blood platelet kinetics

    International Nuclear Information System (INIS)

    Najean, Y.

    1975-01-01

    The blood platelet life span was measured by labelling the circulating population in vivo and in vitro. DF 32 P labelling in vivo: DFP is a specific inhibitor of acetyl-cholinesterase and hence in vivo labels blood platelets in the same way as the red cells and white cells which contain this enzyme. Sodium chromate 51 Cr: this is the method used almost universally and the various stages were described. Several parameters were studied: the percentage of blood platelets in circulation, the aspect of the radioactivity decay curve, blood platelet production. Results obtained by the use of a medulla tracer, 75 Se selenomethionine, were also reported. Finally the practical use of the blood platelet kinetics measurements were demonstrated [fr

  18. Monitoring of a new approach of immunotherapy with allogenic {sup 111}In-labelled NK cells in patients with renal cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Meller, Birgit; Lauer, Isabel; Schelper, Lutz F.; Hof, Katharina von; Richter, Eckart; Baehre, Manfred [Clinic of Radiotherapy and Nuclear Medicine, University of Luebeck, Ratzeburger Allee 160, 23538, Luebeck (Germany); Frohn, Christoph; Brand, Joerg-Matthias; Kirchner, Holger [Institute of Immunology and Transfusion Medicine, University of Luebeck, Ratzeburger Allee 160, 23538, Luebeck (Germany)

    2004-03-01

    The transfusion of allogenic, in vitro expanded natural killer cells (NKC) is a novel therapy option in oncology. To date, however, the biodistribution and kinetics of allogenic NKC have not been investigated. Therefore, in this study three patients with renal cell carcinoma received 3-7 x 10{sup 8} NKC labelled with indium-111 oxine with a tenfold excess of unlabelled cells during NKC therapy. Whole-body scintigrams were obtained (0.5-144 h) in the anterior and posterior views. Scintigrams were analysed using a region of interest technique, and single-photon emission tomography (SPET) studies of the abdomen were performed. Results were compared to those obtained with polymerase chain reaction (PCR) of the peripheral blood (determination of foreign DNA, nested PCR, limit of detection 0.01%). Shortly after transfusion of NKC, more than 50% of the activity was accumulated in the lungs. We observed redistribution effects from lungs to liver, spleen and bone marrow. No significant loss of activity could be detected. In two of four large metastases, tracer accumulation could be proven by SPET. As confirmed by scintigrams and PCR, the fraction of circulating transfused cells was low at all times. Long-term activity retention might be caused either by survival of the allogenic cells, as confirmed by PCR (up to 3 days p.i.), or by phagocytosis of labelled cellular fragments. However, PCR data and uptake in metastases indicated long survival of a portion of allogenic NKC. Such long survival and low retention of the cells in the lung are requirements for an effective immunotherapeutic approach. (orig.)

  19. Calcium-binding proteins from human platelets

    International Nuclear Information System (INIS)

    Gogstad, G.O.; Krutnes, M.B.; Solum, N.O.

    1983-01-01

    Calcium-binding platelet proteins were examined by crossed immunoelectrophoresis of solubilized platelets against antibodies to whole platelets followed by incubation of the immunoplates with 45 Ca 2 + and autoradiography. When the immunoplates had been pretreated with EDTA at pH 9.0 in order to remove divalent cations, three immunoprecipitates were markedly labelled with 45 Ca 2 + . These corresponded to the glycoprotein IIb-IIIa complex, glycoprotein Ia and a presently unidentified antigen termed G18. These antigens were membrane-bound and surface-oriented. When an excess of EDTA was introduced in the incubation media the results revealed that the glycoprotein IIb-IIIa complex and antigen G18, but not glycoprotein Ia, contained sites with a stronger affinity for calcium than has EDTA at pH 7.4 Immunoprecipitates of the separate glycoproteins IIb and IIIa both bound calcium in the same manner as the glycoprotein IIb-IIIa complex. As another approach, platelet-rich plasma was incubated with 45 Ca 2 + prior to crossed immunoelectrophoresis of the solubilized platelets. A single immunoprecipitate was wekly labelled. This did not correspond to any of the immunoprecipitates which were visible after staining with Coomassie blue. The labelling of this antigen was markedly increased when the platelt-rich plasma had been preincubated with EDTA and in this case a weak labelling of the glycoprotein IIB-IIIa precipitate also became apparent. No increased incorporation of calcium occured in any of these immunoprecipitates when the platelets were aggregated with ADP in the presence of 45 Ca 2 + . (orig.)

  20. Bone marrow scintigraphy with 111In-chloride

    International Nuclear Information System (INIS)

    Kan, Masayasu; Miyamae, Tatsuya

    1977-01-01

    111 In-chloride as a useful bone marrow-scanning agent has been used for various hematological diseases. We also have studied the distribution of indium-111 by scintigraphy in 28 patients with systemic hematopoietic disorders and other: 4 with aplastic anemia, 8 with leucemia, 3 with iron-deficiency anemia, one with pernicious anemia, 2 with myelofibrosis, 3 with multiple myeloma, one with malignant lymphoma, 3 with liver cirrhosis or Banti-syndrome and 3 with seminoma received post operative irradiation. The results of scintigraphy (the image of bone marrow, liver, spleen, kidney and intestine) were compared with bone marrow biopsies, ferrokinetic data and Se.I./TIBC. The bone marrow image was interpreted on a three-point scale: normal distribution of activity (+), abnormal distribution (+-), body back ground level (-). In the cases of iron-deficiency anemia and pernicious anemia with hyperplastic erythroid marrow, regardless of its severe anemia, the scintigrams showed clearly delineated bone marrow images and normal organ distribution of indium. On the other hand, the scan images revealed severe suppressions of bone marrow activity and markedly increased renal activity in some cases of aplastic anemia, acute leucemia and malignant lymphoma with hypoplastic and/or tumour-cell infiltrative marrows. Thus, it may be said that the bone marrow uptake of indium-111 correlates well with the degree of erythroid elements, no correlation with nucleated cell counts, and there is a strong tendency to increased renal activity in the cases of markedly decreased erythropoietic cell counts. (auth.)

  1. Positive indium-III bone marrow scan in metastatic breast carcinoma. Case report

    International Nuclear Information System (INIS)

    LaManna, M.M.; Hyzinski, M.; Swami, V.K.; Parker, J.A.

    1984-01-01

    Indium is generally presumed to localize in the bone marrow within the erythroid cell line. Fibrosis, inflammation, lymphoma, extended field radiation, chemotherapy, or combinations of both treatment modalities generally depress the uptake of indium by the marrow in a complex fashion. We report a case of metastatic breast carcinoma and pancytopenia in which the In-111 scan appeared qualitatively similar to a Tc-99m MDP bone scan. Findings were confirmed by bone marrow biopsy

  2. Lea blood group antigen on human platelets

    International Nuclear Information System (INIS)

    Dunstan, R.A.; Simpson, M.B.; Rosse, W.F.

    1985-01-01

    One- and two-stage radioligand assays were used to determine if human platelets possess the Lea antigen. Goat IgG anti-Lea antibody was purified by multiple adsorptions with Le(a-b-) human red blood cells, followed by affinity chromatography with synthetic Lea substance and labeling with 125 I. Human IgG anti-Lea antibody was used either in a two stage radioassay with 125 I-labeled mouse monoclonal IgG anti-human IgG as the second antibody or, alternatively, purified by Staph protein A chromatography, labeled with 125 I, and used in a one-stage radioassay. Platelets from donors of appropriate red blood cell phenotypes were incubated with the antisera, centrifuged through phthalate esters, and assayed in a gamma scintillation counter. Dose response and saturation curve analysis demonstrate the presence of Lewis a antigen on platelets from Lea+ donors. Furthermore, platelets from an Le(a-b-) donor incubated in Le (a+b-) plasma adsorb Lea antigen in a similar manner to red blood cells. The clinical significance of these antigens in platelet transfusion remains undefined

  3. Selection of donor platelets for alloimmunized patients using a platelet-associated IgG assay

    International Nuclear Information System (INIS)

    Myers, T.J.; Kim, B.K.; Steiner, M.; Baldini, M.G.

    1981-01-01

    A quantitative immunofluorescence platelet-associated immunoglobulin-G (PA-IgG) assay was used to detect alloimmunity to platelets in 8/12 multitransfused patients and to perform platelet crossmatching in the 8 alloimmunized patients. The correct separation of multitransfused patients into alloimmune and nonalloimmune groups was substantiated with chromium-51-labeled platelet survival studies. For 5 alloimmunized patients, compatible and incompatible donor platelets were demonstrated by PA-IgG crossmatching and were confirmed by platelet survival studies. With the other 3 alloimmunized patients, only Pa-IgG incompatible donor platelets were found. Survival studies with 5 of these incompatible donor platelets showed markedly reduced survival times on 4 occasions. Pa-IgG compatible donor platelets survived 3.5 to 8.7 days, while Pa-IgG incompatible platelets showed survival times of 0.1 to 2.4 days

  4. Heterogeneity of rabbit platelets

    International Nuclear Information System (INIS)

    Karpatkin, S.

    1978-01-01

    Rabbits were injected intravenously with a cohort platelet label, 75 Se-selenomethionine. Platelet-rich plasma was separated into five different platelet density fractions on each of seven days by repetitively centrifuging the same sample of platelet-rich plasma at increasing gravitational force. The heaviest platelet sediment fraction was enriched with larger platelets. The lightest platelet sediment fraction was enriched with smaller platelets. Incorporation of isotope into the heaviest platelet fraction was considerably greater than incorporation into the lightest platelet fraction. The mean platelet survival of the lightest two fractions was significantly shorter than that of the heaviest three fractions. SDS-polyacrylamide gel electrophoresis of the platelet cell sap generally revealed 10 prominent protein bands for the heaviest platelet fractions. The lightest platelet fraction had six absent to markedly diminished platelet proteins. The data are compatible with two models, (1) heavy-large platelets are, on average, young platelets which become lighter-smaller platelets while losing platelet membranes and cell sap components with time. (2) Heavy-large platelets and light-small platelets are produced independently by specific megakarocytes. The heavy-large platelets incorporate more isotope that lighter-smaller platelets (possibly because of their megakarocyte precursor). However, they are released earlier into the circulation than lighter-smaller platelets and are therefore younger platelets. The light-smaller platelets which are released later into the circulation have a shorter survival. (author)

  5. Studies on the hepatic uptake of In-111 labeled monoclonal antibodies and the method to reduce the hepatic uptake

    International Nuclear Information System (INIS)

    Kinuya, Seigo

    1990-01-01

    Prolonged retention of In-111 labeled monoclonal antibody (In-111 MoAb) in the liver poses problems in radioimmunoscintigraphy. Therefore, subcellular kinetics of In-111 MoAb was investigated. In a study with In-111 225.28S in normal SD rats, the supernatant was found to be a predominant fraction of In-111 radioactivity (61% at 3 hr), with the activity decreasing with time to 21% at 72 hr; however, activity of the mitochondrial fraction was found to increase from 11% to 44%. High performance liquid chromatography for the supernatant revealed that In-111 activity at the earlier time was mainly eluted with the intact IgG peak, and that the major peak activity was thereafter reduced with associated activity peaks found in smaller moistly fractions. Such a sequential distribution change of In-111 225.28S was not found when labeled with I-125. A study with In-111 ZCE025 in mice bearing human colon cancer revealed that activity of the supernatant fraction decreased with time, but the lysosomal activity increased from 14% to 29%, as found in the experiment using normal rats. In tumors, the subcellular distribution of In-111 radioactivity almost remained unchanged throughout the study. The lysosomal fraction was not a predominant fraction of In-111 radioactivity in tumors. When 4 mg of ferric ion (Fe) was administered 48 hr before the injection of In-111 ZCE025, liver uptake of In-111 decreased as compared with the non-Fe group, but tumor uptake was unchanged. Intrahepatic lysosomal radioactivity was smaller in the Fe group than the non-Fe group. These results indicated the involvement of lysosomes in hepatic retention of In-111 MoAb. Once taken up by the liver, the MoAb was metabolized in the supernatant and In-111 ion was transchelated from DTPA onto the lysosomal substances resulting in prolonged retention in the liver. The lysosome in the liver could be saturated by Fe, resulting in a decrease of hepatic uptake without a decrease of tumor uptake. (N.K.) 53 refs

  6. 21 CFR 111.127 - What quality control operations are required for packaging and labeling operations?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for... and Process Control System: Requirements for Quality Control § 111.127 What quality control operations are required for packaging and labeling operations? Quality control operations for packaging and...

  7. Radiolabeling of human platelets using four radiopharmaceuticals with Tc-99m

    International Nuclear Information System (INIS)

    Portillo L, M.C.; Godoy, C.

    1991-01-01

    The present investigation work has been done in an evaluation of four different radiopharmaceuticals with Tin II (Glucoheptonate, Pyrophosphate, Citrate and DTPA), with the purpose of determining which one of the four would be obtained a higher rate of radiolabeling of platelets with Tc-99m. In order to evaluate the four radiopharmaceuticals it was procede to the separation and labeling of the human platelets. It was worked with samples of blood from five pacients, and the platelets from each one of them were labeled with the radiopharmaceuticals-Tc-99m. Then was observed a significant difference among the four radiopharmaceuticals studied, with a reliable level of 0.05 being the Glucoheptonate-Tc-99m the best to label platelets, obtaining with the same 50.23% of labeling efficiency, while for DTPA, Pyrophosphate and Citrate, It was obtained 33.42%, 29.82% and |2.62% respectively. Also, it was studied the biodistribution of the labeled platelets, using Glucoheptonate-Tc-99m as a radiopharamceutical. The biodistribution was studied in white mice at different times and it was founded that the place of biodistribution of the labeled platelets is given in greater percentage in the liver, spleen, lungs and kydneis. (Author)

  8. 111In leukocyte scintigraphy in the diagnosis of vascular graft infection

    International Nuclear Information System (INIS)

    Royen, E.A. van; Roevekamp, M.H.; Dongen, R.J.A.M. van; Schoot, J.B. van der; Hardeman, M.R.

    1982-01-01

    Infection at the site of a vascular graft is a serious complication in vascular surgery especially when synthetic materials have been used. Prosthetic grafts are widely employed in aorto-iliac, aorto-femoral and femoro-popliteal bypasses. X-ray investigation, angiography, ultrasound and computer tomography are of limited value in the diagnosis of graft infection. Delay in diagnosis and treatment of this complication results in a high morbidity and mortality. Some reports are available on the use of gallium-67 citrate scintigraphy. However, its accumulation in normal intestinal structures is a serious drawback. The authors investigated the effectiveness of indium-111 leukocytes scintigraphy in the diagnosis of vascular graft infection. The possible accumulation of labelled leukocytes was assessed both subjectively by visual interpretation and quantitatively by computer evaluation. (Auth.)

  9. Antibody guided targeting of non-small cell lung cancer using 111In-labeled HMFG1 F(ab')2 fragments

    International Nuclear Information System (INIS)

    Kalofonos, H.P.; Sivolapenko, G.B.; Courtenay-Luck, N.S.

    1988-01-01

    Immunoscintigraphy using F(ab')2 fragments of tumor-associated monoclonal antibody HMFG1 was performed in 14 patients with primary and metastatic non-small cell carcinoma of lung cancer. The antibody was conjugated with diethylenetriamine pentaacetic acid and labeled with 111 In. Quality control studies showed efficient incorporation of 111 In onto antibody (5 mCi/mg), no significant loss of immunoreactivity, and in vitro and in vivo stability. The optimal time for imaging was between 48 and 72 h. Following i.v. administration, serum activity fell rapidly (t1/2a = 2.5 +/- 1.3 (SD) h; t1/2b = 42 +/- 4.5 h). The majority of the radioactivity was associated with the plasma and not with the blood cells. All patients had a significant concentration of 111 In in the liver (approximately 20% of the injected dose, 48 h postadministration). No toxicity was encountered. No human antimurine-IgG antibody was detected in any of the patients within 4 months of follow-up, even in patients receiving two administrations of F(ab')2 fragments. Localization of all primary lesions and the majority (80%) of metastatic lesions was achieved. Seven of 14 patients were also studied using a 111 In-labeled nonspecific antibody (Fab')2 fragment (4C4). In three patients the specificity index was higher than the other four (P less than 0.05). We conclude that although successful targeting of 111 In-labeled (Fab')2 fragments of HMFG1 can be achieved in patients with non-small cell carcinoma of lung, observable tumor localization can also be achieved using a nonspecific antibody

  10. Technetium 99m-labeled annexin v scintigraphy of platelet activation in vegetations of experimental endocarditis

    International Nuclear Information System (INIS)

    Rouzet, F.; Sarda-Mantel, L.; Le Guludec, D.; Rouzet, F.; Sarda-Mantel, L.; LeGuludec, D.; Rouzet, F.; Sarda-Mantel, L.; Le Guludec, D.; Hernandez, M.D.; Louedec, L.; Michel, J.B.; Hervatin, F.; Lefort, A.; Fantin, B.; Duval, X.; Duval, X.; Hernandez, M.D.

    2008-01-01

    Background: The pathophysiology of infective endocarditis involves a pathogen/host tissue interaction, leading to formation of infected thrombotic vegetations. Annexin V is a ligand of phosphatidyl-serines exposed by activated platelets and apoptotic cells. Because vegetations are platelet-fibrin clots in which platelet pro-aggregant activity is enhanced by bacterial colonization, we investigated the ability of annexin V labeled with technetium 99m Tc ( 99m Tc-ANX) to provide functional imaging of these vegetations in experimental models of infective endocarditis. This ability was assessed in rabbits and rats because of the different interest of these 2 species in preclinical analysis. Methods and Results: Non-bacterial thrombotic endocarditis was induced with the use of a catheter left indwelling through the aortic or tricuspid valve, and animals were injected with either a bacterial inoculum or saline. Scintigraphic investigations were performed 5 days later and showed a higher 99m Tc-ANX uptake by vegetations in infected versus non-infected animals (ratio,1.3 for in vivo acquisitions and 2 for autoradiography; P ≤ 0.0001 for all), whereas no significant uptake was present in controls. Right-sided endocarditis was associated with pulmonary uptake foci corresponding to emboli. Histological analysis of vegetations showed a specific uptake of 99m Tc-ANX at the interface between circulating blood and vegetation. In parallel, underlying myocardial tissue showed myocyte apoptosis and mucoid degeneration, without extracellular matrix degradation at this stage. Conclusions: 99m Tc-ANX is suitable for functional imaging of platelet-fibrin vegetations in endocarditis, as well as embolic events. 99m Tc-ANX uptake reflects mainly platelet activation in the luminal layer of vegetations. This uptake is enhanced by bacterial colonization. (authors)

  11. Decomposition rates of radiopharmaceutical indium chelates in serum

    International Nuclear Information System (INIS)

    Yeh, S.M.; Meares, C.F.; Goodwin, D.A.

    1979-01-01

    The rates at which six small aminopolycarboxylate chelates of trivalent 111 In and three protein-bound chelates of 111 In deliver indium to the serum protein transferrin have been studied in sterile human serum at pH 7.3, 37 deg C. Sterically hindered chelates containing a substituent on an ethylene carbon of EDTA decompose with rates in the range 0.03 to 0.11% per day - one to two orders of magnitude slower than other chelates. Only small differences are observed between rates of decomposition for low-molecular-weight chelates and for protein-bound chelates having analogous structures. (author)

  12. Human breast tumor imaging using 111In labeled monoclonal antibody: Anthymic mouse model

    International Nuclear Information System (INIS)

    Ban An Khaw; Massachusetts General Hospital, Boston; Bailes, J.S.; Schneider, S.L.; Lancaster, J.; Lasher, J.C.; McGuire, W.L.; Powers, J.; Strauss, H.W.

    1988-01-01

    The monoclonal antibody (MoAb) 323/A3, an IgG1, was raised against the human breast tumor cell line MCF-7 and recognized a 43 Kd membrane associated glycoprotein. Histochemical studies with the antibody detected 75% of metastatic lymph nodes, 59% of primary breast tumors, and showed some staining in 20% of benign breast lesions. For radionuclide imaging, the MoAb 323/A3 was labeled with both 125 I and 111 In, via covalently coupled diethylenetriaminepentaacetic acid (DTPA) by the mixed anhydride method. The antibody activity of the DTPA modified 323/A3 was assessed by an immunoassay using viable and fixed MCF-7 target cells. Male athymic nude mice bearing BT-20 human mammary tumors were injected with dual 125 I/ 111 In labeled DTPA 323/A3 via the tail veins. The animals were imaged with a gamma camera equipped with a pinhole collimator at 1-3 h, 1, 2, 3, 4 and 5 days after the tracer administration. On day 5 or 6, the animals were killed, and the biodistribution of the radiotracers was determined for the blood, thyroid, heart, lungs, liver, spleen, kidneys, gastro-intestinal tract and tumor. Target to blood ratio at 6 days for the 111 In tracer was 24:1 in the group with a mean tumor weight of 0.492 g, and 13:1 in another group with a mean tumor weight of 0.1906 g (day 5). However, the 125 I activity showed only 3.6:1 and 5.4:1 target to blood ratios in the corresponding groups. The larger tumors localized less 111 I tracer (27.13%±7.57% injected dose/g, Mean±SD) than the smaller tumors (52.75%±22.25% ID/g). Analysis of the gamma images showed that the maximum tracer concentration occurred in the tumors at about 2 to 3 days after intravenous tracer administration. The excellent tumor resolution observed with BT-20 tumors may be due to increased 43 Kd glycoprotein antigen density in this tumor cell line. (orig.)

  13. Gamma scintigraphy imaging of murine invasive pulmonary aspergillosis with a {sup 111}In-labeled cyclic peptide

    Energy Technology Data Exchange (ETDEWEB)

    Yang Zhi [Department of Experimental Diagnostic Imaging, Infection Control and Employee Health, University of Texas M.D. Anderson Cancer Center, Houston, TX 77030 (United States); Kontoyiannis, Dimitrios P. [Department of Infectious Diseases, Infection Control and Employee Health, University of Texas M.D. Anderson Cancer Center, Houston, TX 77030 (United States); Wen Xiaoxia; Xiong Chiyi; Zhang Rui [Department of Experimental Diagnostic Imaging, Infection Control and Employee Health, University of Texas M.D. Anderson Cancer Center, Houston, TX 77030 (United States); Albert, Nathaniel D. [Department of Infectious Diseases, Infection Control and Employee Health, University of Texas M.D. Anderson Cancer Center, Houston, TX 77030 (United States); Li Chun [Department of Experimental Diagnostic Imaging, Infection Control and Employee Health, University of Texas M.D. Anderson Cancer Center, Houston, TX 77030 (United States)], E-mail: cli@mdanderson.org

    2009-04-15

    Introduction: Invasive pulmonary aspergillosis (IPA) is a leading cause of infection-associated death in immunosuppressed patients. Early detection and early administration of antifungal therapy are critical factors in improving outcome for patients with IPA. Here, we evaluated the imaging properties of a {sup 111}In-labeled cyclic peptide targeted to Aspergillus fumigatus in an immunosuppressed murine model of IPA. Methods: A cyclic peptide c(CGGRLGPFC)-NH{sub 2} was labeled with {sup 111}In by means of diethylenetriaminepentaacetic acid (DTPA). Two days after intranasal inoculation of 17.5x10{sup 6} conidia of A. fumigatus, mice were injected {sup 111}In-DTPA-c(CGGRLGPFC)-NH{sub 2} intravenously. Biodistribution data were obtained at 2 h, and {gamma}-images were acquired at 10 min and 2 h after radiotracer injection. Healthy mice were used as controls. In addition, a group of infected mice were co-injected with the radiotracer and unlabeled c(CGGRLGPFC)-NH{sub 2} to evaluate the inhibition of radiotracer's binding to infected lungs. Autoradiographs of lungs from infected and healthy mice were compared with corresponding photographs of transaxial sections of the lung tissues stained for A. fumigatus hyphae. Results: The labeling efficiency was >98%, with specific radioactivity of up to 74 MBq/nmol peptide. Significantly higher uptake of {sup 111}In-DTPA-c(CGGRLGPFC)-NH{sub 2} was observed in the lungs of mice infected with A. fumigatus than in those of healthy mice (0.37{+-}0.06 %ID/g vs. 0.14{+-}0.02 %ID/g, P=.00044). Simultaneous injection with unlabeled peptide reduced radioactivity in the infected lungs by 41% (P=.0037). Increased radioactivity in the lungs of infected mice was visible in {gamma} images at both 10 min and 2 h after radiotracer injection. Moreover, autoradiography confirmed radiotracer uptake in infected lungs, but not in the lungs of healthy mice or infected mice co-injected with unlabeled peptide. Conclusions: {gamma}-Imaging with {sup

  14. Granulocyte migration in uncomplicated intestinal anastomosis in man

    Energy Technology Data Exchange (ETDEWEB)

    Keshavarzian, A.; Gibson, R.; Guest, J.; Spencer, J.; Lavender, J.P.; Hodgson, H.J.

    1986-03-01

    We have investigated the presence, duration, and clinical significance of granulocyte accumulation, using indium-111 granulocyte scanning, in patients following uncomplicated intestinal anastomosis. Eight patients underwent intestinal resection and anastomosis (right hemicolectomy, 5; sigmoid colectomy, 2; ileal resection, 1) for carcinoma, angiodysplasia, or perforation. All patients had an uneventful postoperative course, with no evidence of any leakage or infection. Indium-111 granulocyte scan and abdominal ultrasound were performed 7-20 days (12 +/- 4.7 means +/- SD) following surgery. Indium-111 granulocyte scan showed the presence of labeled granulocytes at the site of anastomosis in all patients. In three of eight, cells subsequently passed into the lumen of the bowel. In contrast, granulocytes were not visualized along the abdominal incision. Thus, in contrast to skin wounds, granulocytes continue migrating into the intestinal wall in areas of anastomosis for at least up to 20 days following surgical trauma. They may play a significant role both in healing the anastomosis and in preventing systemic bacterial infection. Moreover, indium-111 granulocyte scans following intestinal surgery should be interpreted with care, and the presence of labeled granulocytes around anastomoses does not necessarily indicate abscess formation.

  15. Granulocyte migration in uncomplicated intestinal anastomosis in man

    International Nuclear Information System (INIS)

    Keshavarzian, A.; Gibson, R.; Guest, J.; Spencer, J.; Lavender, J.P.; Hodgson, H.J.

    1986-01-01

    We have investigated the presence, duration, and clinical significance of granulocyte accumulation, using indium-111 granulocyte scanning, in patients following uncomplicated intestinal anastomosis. Eight patients underwent intestinal resection and anastomosis (right hemicolectomy, 5; sigmoid colectomy, 2; ileal resection, 1) for carcinoma, angiodysplasia, or perforation. All patients had an uneventful postoperative course, with no evidence of any leakage or infection. Indium-111 granulocyte scan and abdominal ultrasound were performed 7-20 days (12 +/- 4.7 means +/- SD) following surgery. Indium-111 granulocyte scan showed the presence of labeled granulocytes at the site of anastomosis in all patients. In three of eight, cells subsequently passed into the lumen of the bowel. In contrast, granulocytes were not visualized along the abdominal incision. Thus, in contrast to skin wounds, granulocytes continue migrating into the intestinal wall in areas of anastomosis for at least up to 20 days following surgical trauma. They may play a significant role both in healing the anastomosis and in preventing systemic bacterial infection. Moreover, indium-111 granulocyte scans following intestinal surgery should be interpreted with care, and the presence of labeled granulocytes around anastomoses does not necessarily indicate abscess formation

  16. Influences of residual oxygen impurities, cubic indium oxide grains and indium oxy-nitride alloy grains in hexagonal InN crystalline films grown on Si(111) substrates by electron cyclotron resonance plasma-assisted molecular beam epitaxy

    International Nuclear Information System (INIS)

    Yodo, T.; Nakamura, T.; Kouyama, T.; Harada, Y.

    2005-01-01

    We investigated the influences of residual oxygen (O) impurities, cubic indium oxide (β-In 2 O 3 ) grains and indium oxy-nitride (InON) alloy grains in 200 nm-thick hexagonal (α)-InN crystalline films grown on Si(111) substrates by electron cyclotron resonance plasma-assisted molecular beam epitaxy. Although β-In 2 O 3 grains with wide band-gap energy were formed in In film by N 2 annealing, they were not easily formed in N 2 -annealed InN films. Even if they were not detected in N 2 -annealed InN films, the as-grown films still contained residual O impurities with concentrations of less than 0.5% ([O]≤0.5%). Although [O]∝1% could be estimated by investigating In 2 O 3 grains formed in N 2 -annealed InN films, [O]≤0.5% could not be measured by it. However, we found that they can be qualitatively measured by investigating In 2 O 3 grains formed by H 2 annealing with higher reactivity with InN and O 2 , using X-ray diffraction and PL spectroscopy. In this paper, we discuss the formation mechanism of InON alloy grains in InN films. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  17. The effect of alpha-interferon on bone marrow megakaryocytes and platelet production rate in essential thrombocythemia

    International Nuclear Information System (INIS)

    Wadenvik, H.; Kutti, J.; Ridell, B.; Revesz, P.; Jacobsson, S.; Magnusson, B.; Westin, J.; Vilen, L.

    1991-01-01

    In 10 patients with previously untreated essential thrombocythemia (ET), by using 111 In-labeled platelets and megakaryocyte morphometry, the relation between platelet production rate and bone marrow megakaryocytes was evaluated before and during alpha-2b-interferon (IFN) therapy. A highly significant decrease in platelet count occurred during IFN therapy; the platelet counts, at baseline and after 2 and 6 months of IFN therapy, were 1,102 +/- 345 x 10(9)/L, 524 +/- 169 x 10(9)/L (P less than .0001), and 476 +/- 139 x 10(9)/L (P less than .0001), respectively. The decrement in platelet count was mainly a result of diminished platelet production rate, which at baseline and after 2 and 6 months of IFN therapy was 89 +/- 30 x 10(10) platelets/d, 53 +/- 18 x 10(10) platelets/d (P = .0033), and 45 +/- 20 x 10(10) platelets/d (P less than .0001), respectively. Also, a slight shortening of platelet mean life-span (MLS) was observed in response to IFN treatment; platelet MLS was 7.96 +/- 0.69 days at baseline and 6.68 +/- 1.30 days (P = .012) after 6 months of IFN therapy. IFN induced a significant decrease in bone marrow megakaryocyte volume; both megakaryocyte nuclear and cytoplasmatic volumes were affected. The mean megakaryocyte volume was 372 +/- 126 x 10(2) pL/microL at baseline and 278 +/- 147 x 10(2) pL/microL (P = .049) after 6 months of IFN therapy. However, the number of megakaryocytes did not show any significant change in response to IFN. It is concluded that alpha-IFN reduces platelet production rate and the peripheral platelet count in ET mainly through an anti-proliferative action on the megakaryocytes and to a considerably lesser degree by a shortening of platelet MLS

  18. New primate model for the study of intravenous thrombotic potential and its modification

    International Nuclear Information System (INIS)

    Shoenfeld, N.A.; Yeager, A.; Connolly, R.; Ramberg, K.; Forgione, L.; Giorgio, A.; Valeri, C.R.; Callow, A.D.

    1988-01-01

    Advances in venous reconstruction have been limited by inherent venous thrombogenicity and the absence of a suitable prosthetic material for use in the venous system. We have designed an in vivo experimental model to evaluate early blood-material interactions within the venous system and to quantitate drug efficacy in the alteration of platelet function and fibrin deposition in the baboon. An 8F catheter was placed percutaneously in the femoral vein of an adult male baboon. Indium 111-labeled autogenous platelets or iodine 125-labeled human fibrinogen was infused before the introduction, into the inferior vena cava, of a linear array of 5 x 15 mm alternating Dacron and polytetrafluoroethylene samples attached to a benzalkonium-heparin-treated guide wire. At 60 or 120 minutes the samples were removed and a 1 ml aliquot of blood was drawn. The materials and blood samples were counted in a gamma well counter, and the material counts were normalized to the circulating label present in the 1 ml blood sample. The experiment was repeated after pretreatment with heparin, aspirin, or dextran. Whole blood clotting times and bleeding times were monitored. The results showed decreased platelet and fibrin deposition on polytetrafluoroethylene when compared with Dacron in the venous system. Aspirin, heparin, and dextran were all found to decrease platelet and fibrin deposition onto intravenously placed graft material samples (p less than 0.05, Student's t test). The data confirm the ability of the model to evaluate quantitatively anticoagulants, antiplatelet agents, and prospective graft materials for use in venous reconstructions

  19. Evidence for atomic scale disorder in indium nitride from perturbed angular correlation spectroscopy

    International Nuclear Information System (INIS)

    Dogra, R; Shrestha, S K; Byrne, A P; Ridgway, M C; Edge, A V J; Vianden, R; Penner, J; Timmers, H

    2005-01-01

    The crystal lattice of bulk grains and state-of-the-art films of indium nitride was investigated at the atomic scale with perturbed angular correlation spectroscopy using the 111 In/Cd radioisotope probe. The probe was introduced during sample synthesis, by diffusion and by ion implantation. The mean quadrupole interaction frequency ν Q = 28 MHz was observed at the indium probe site in all types of indium nitride samples with broad frequency distributions. The observed small, but non-zero, asymmetry parameter indicates broken symmetry around the probe atoms. Results have been compared with theoretical calculations based on the point charge model. The consistency of the experimental results and their independence of the preparation technique suggest that the origin of the broad frequency distribution is inherent to indium nitride, indicating a high degree of disorder at the atomic scale. Due to the low dissociation temperature of indium nitride, furnace and rapid thermal annealing at atmospheric pressure reduce the lattice disorder only marginally

  20. Technetium 99m-labeled annexin v scintigraphy of platelet activation in vegetations of experimental endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Rouzet, F.; Sarda-Mantel, L.; Le Guludec, D. [Nucl Med Serv, Grp Hosp Bichat Claude Bernard, AP-HP, Paris (France); Rouzet, F.; Sarda-Mantel, L.; LeGuludec, D. [Univ Denis Diderot Paris 7, UMR S773, Paris (France); Rouzet, F.; Sarda-Mantel, L.; Le Guludec, D. [INSERM, U773, Paris (France); Hernandez, M.D.; Louedec, L.; Michel, J.B. [Univ Paris 07, CHU Xavier Bichat, INSERM, U698, Paris (France); Hervatin, F. [CEA, DSV, DRM, SHFJ, Orsay (France); Lefort, A.; Fantin, B. [Univ Denis Diderot Paris 7, EA 3964, Paris (France); Duval, X. [Univ Denis Diderot Paris 7, INSERM, CIC 007, Paris (France); Duval, X. [Univ Denis Diderot Paris 7, AP-HP, Grp Hosp Bichat Claude Bernard, Ctr Invest Clin, Paris (France); Hernandez, M.D. [Univ Guadalajara, DeptPathol, Guadalajara 44430, Jalisco (Mexico)

    2008-07-01

    Background: The pathophysiology of infective endocarditis involves a pathogen/host tissue interaction, leading to formation of infected thrombotic vegetations. Annexin V is a ligand of phosphatidyl-serines exposed by activated platelets and apoptotic cells. Because vegetations are platelet-fibrin clots in which platelet pro-aggregant activity is enhanced by bacterial colonization, we investigated the ability of annexin V labeled with technetium {sup 99m}Tc ({sup 99m}Tc-ANX) to provide functional imaging of these vegetations in experimental models of infective endocarditis. This ability was assessed in rabbits and rats because of the different interest of these 2 species in preclinical analysis. Methods and Results: Non-bacterial thrombotic endocarditis was induced with the use of a catheter left indwelling through the aortic or tricuspid valve, and animals were injected with either a bacterial inoculum or saline. Scintigraphic investigations were performed 5 days later and showed a higher {sup 99m}Tc-ANX uptake by vegetations in infected versus non-infected animals (ratio,1.3 for in vivo acquisitions and 2 for autoradiography; P {<=} 0.0001 for all), whereas no significant uptake was present in controls. Right-sided endocarditis was associated with pulmonary uptake foci corresponding to emboli. Histological analysis of vegetations showed a specific uptake of {sup 99m}Tc-ANX at the interface between circulating blood and vegetation. In parallel, underlying myocardial tissue showed myocyte apoptosis and mucoid degeneration, without extracellular matrix degradation at this stage. Conclusions: {sup 99m}Tc-ANX is suitable for functional imaging of platelet-fibrin vegetations in endocarditis, as well as embolic events. {sup 99m}Tc-ANX uptake reflects mainly platelet activation in the luminal layer of vegetations. This uptake is enhanced by bacterial colonization. (authors)

  1. Inflammation Scan Using {sup 99m}Tc-HMPAO Labelled Leukocytes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Woo Jin; Chung, Soo Kyo; Shinn, Kyung Sub; Bahk, Yong Whee; Kim, Hoon Kyo [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1989-07-15

    Inflammation scan using radiolabelled leukocytes has high sensitivity and specificity. Several methods for labelling leukocytes have been evaluated using P-32 diisopropyl fluorophosphate (DFP -32), H-3 thymidine, Cr-51 chromate, Ga-67 citrate and {sup 99m}Tc-sulfur colloid. In-111-oxine has proved so far to be the most reliable agent for labelling leukocytes. In-111-oxine is, however, expensive, not easily available when needed, and its radiation dose to leukocytes is relatively high. Moreover, resolution of the resultant image is relatively poor. {sup 99m}Tc is still the agent of choice because of, as compared with the indium, its favorable physical characteristics, lower cost and availability. Now the technique for labelling the leukocytes with technetium is successfully obtained using the lipophilic HMPAO with higher efficiency for granulocytes than for other cells. With this technique it is possible to label leukocytes in plans to improve the viability of the leukocytes. Inflammation scan using {sup 99m}Tc-HMPAO has been evaluated in several laboratories, and difference in methods for separation and labelling accounts for difference in efficiency, viability and biodistribution of the labelled leukocytes. We performed inflammation scan using leukocytes labelled with {sup 99m}Tc-HMPAO in three dogs 24 hours after inoculation of live E. Coli and S. Aureus in their right abdominal wall. We separated mixed leukocytes by simple sedimentation using 6% hetastarch (HES) and labelled the leukocytes with {sup 99m}Tc-HMPAO in 20% cell free plasma diluted with phosphate buffer solution. Uptake was high in the liver and spleen but is was minimal in the lungs on whole body scan. Kidneys and intestine showed minimal activity although it was high in the urinary bladder. Uptake of labelled leukocytes in the inflammation site was definite on 2 hour-postinjection scan and abscess was clearly delineated on 24 hour-delayed scan with high target-to-nontarget ratio. 4). Inflammation

  2. Sequential functional imaging with technetium-99m hexakis-2-methoxyisobutylisonitrile and indium-111 octreotide: can we predict the response to chemotherapy in small cell lung cancer?

    International Nuclear Information System (INIS)

    Moretti, J.L.; Caglar, M.; Boaziz, C.; Caillat-Vigneron, N.; Morere, J.F.

    1995-01-01

    A case of small cell lung carcinoma (SCLC) demonstrating uptake on functional indium-111 octreotide scintigraphy is presented. Technetium-99m hexakis-2-methoxyisobutylisonitrile (MIBI) scintigraphy clearly delineated an absence of radionuclide uptake at the tumour site. This suggested the presence of multidrug resistance-mediated P glycoprotein (Pgp) on tumour cells, which recognizes certain chemotherapeutic agents as well as MIBI as a substrate and avoids radionuclide concentration. Following three courses of chemotherapy, the patient failed to improve and eventually died. This case demonstrates the importance of functional images, which have the potential to predict the outcome in response to chemotherapy. (orig.)

  3. Radiolabelled blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Lavender, J.P.

    1986-12-01

    After the introduction of gamma-emitting labels for blood-cells the use of radio-labelled blood cells is not only limited to kinetics of blood cells but it is also possible to localise inflammations, abscesses and thrombus. The most commonly applied label for red cells is Tc-99m. The most widely used technique for labelling granulocytes or platelets is In-111-oxine. In future the labelling of blood cells will be more simple and more specific due to monoclonal antibodies onto the platelet or the granulocyte cell surface. Labelled red cells have their main application in blood-pool imaging and in localisation of gastrointestinal bleeding. Besides the determination of the platelet life-span in haematologic disorders labelled platelets allow to localise thrombus and to show abnormal vasculature in the rejecting kidney. The commonest application for In-111-oxin labelled granulocytes is to show abdominal inflammations to localise inflamed bowel segments and to assess the inflammatory activity in chronic inflammatory bowel diseases. Moreover brain abscesses, bone sepsis and lung sepsis can be identified.

  4. Determination of blood loss during dialysis with capillary and plate dialyzers using 111 In-labelled erythrocytes

    International Nuclear Information System (INIS)

    Sinn, H.; Schueler, H.W.; Horsch, R.; Ostertag, H.; Clorius, J.; Moehring, K.

    1976-01-01

    Two types of Hollow Fiber Artificial Kidneys and four different types of plate-dialyzers were investigated with 111-In-labelled red-cells, to quantify the bloodloss during dialyzation. The different dialyzers showed significant differences in this respect. Two models were found to be superior, since they regularly caused only a minimal bloodloss

  5. Bone marrow scintigraphy with 111In-chloride

    International Nuclear Information System (INIS)

    Fujishima, Mamoru; Hiraki, Yoshio; Takeda, Yoshihiro; Kohno, Yoshihiro; Niiya, Harutaka; Aono, Kaname; Yorimitsu, Seiichi; Takahashi, Isao

    1988-01-01

    Bone marrow scintigraphy with indium chloride ( 111 In) was performed in fifty-one patients with the hematological diseases. The results of the investigation were that 1) in all patients, as well as in patients with aplastic anemia, no correlation was there between the degree of the indium chloride accumulation and peripheral blood counts, 2) in patients with aplastic anemia and pure red cell aplasia (PRCA) a tendency to reduction in uptake of indium chloride in bone marrow, 3) in patients with these two good correlation between the degree of indium chloride accumulation and histology of the erythroid bone marrow, but in patients with chronic myelocytic leukemia (CML) and atypical leukemia no correlation between the two, so it seemed unlikely that indium chloride should reflect the effective production of erythrocytes, 4) four patients with leukemia were studied with indium chloride bone marrow imaging two times to evaluate their responses to chemotherapy, and peripheral expansion was no change or reduced in two patients with acute myelocytic leukemia (AML) and one patient with acute lymphocytic leukemia (ALL) who obtained complete remission, but on the other hand, it enlarged in one patient with acute myelocytic leukemia who obtained partial remission, and 5) in two patients with chronic myelocytic leukemia it enlarged up to the ankle joints, which was considerably specific. (author)

  6. Activation analysis of indium used as tracer in hydrogeology

    International Nuclear Information System (INIS)

    Stanescu, S.P.; Farcasiu, O.M.; Gaspar, E.; Spiridon, S.; Nazarov, V.M.; Frontasieva, M.V.

    1985-01-01

    About 2500 samples of 18 hydro-karstic structures from Romania have been analyzed. The water flow rates were in the range of 0.05 to 2.7 m 3 /s and transit time values were from 30 h to 200 days. The quantity of indium used for a labelling was a calculated function of the emergency flow rate and the estimated transit time and varied from 1 to 100 g. The results prove that the activation analysis of indium in water samples combined with preconcentration by coprecipitation is an useful method in hydrogeological studies

  7. Location and activity of ulcerative and Crohn's colitis by 111In leukocyte scan. A prospective comparison study

    International Nuclear Information System (INIS)

    Stein, D.T.; Gray, G.M.; Gregory, P.B.; Anderson, M.; Goodwin, D.A.; McDougall, I.R.

    1983-01-01

    A prospective blinded study comparing the 111 In leukocyte scan to barium enema, colonoscopy, or surgery or a combination of these, was carried out in 15 patients (10 with active ulcerative colitis and 5 with active Crohn's colitis). Correlation of disease location to colonic regions between indium scan and other diagnostic studies was excellent in 11 instances, good in 2, and poor in 3. In 2 of the 3 studies where major disagreement occurred, the comparative barium enema was performed greater than 2 mo after the indium scan. Disease activity, estimated by the intensity of radionuclide uptake, was compared to clinical disease activity assessed by the Crohn's Disease Activity Index for both forms of colitis. The relative degree of inflammation estimated by the indium scan correlated well with the independent clinical assessment (correlation coefficient . 0.81). The indium 111 leukocyte scan appears to be an accurate, noninvasive method for assessing the extent and the severity of the inflammation in patients with acute ulcerative or Crohn's colitis

  8. Diagnostic imaging of lung cancer with In-111-MDEGD

    International Nuclear Information System (INIS)

    Nakajima, Susumu; Hayashi, Hideo; Maeda, Tomio

    1987-01-01

    Indium-111-mono DTPA-ethyleneglycol Ga deuterporphyrin (In-111-MDEGD) is a new tumor imaging agent in lung cancer. The agent has been studied with golden hamsters bearing adenocarcinoma, C57 black mice bearing Lewis lung adenocarcinoma, and nude mice bearing human lung adenocarcinoma xerografts. It has been revealed that the tumor-to-lung, tumor-to-kidney, and tumor-to-blood ratios are higher for In-111-MDEGD than for Ga-67 citrate widely used in imaging tumors, and that the agent is not accumulated in inflammatory lesions. The results were encouraging enough to start clinical diagnostic trials in lung cancer. In this paper, an overview of In-111-MDEGD, along with its preliminary data, is given. (Namekawa, K.)

  9. The pharmacological modulation of thrombin-induced cerebral thromboembolism in the rabbit.

    Science.gov (United States)

    May, G. R.; Paul, W.; Crook, P.; Butler, K. D.; Page, C. P.

    1992-01-01

    1. Intracarotid (i.c.) administration of thrombin induced a marked accumulation of 111indium-labelled platelets and 125I-labelled fibrinogen within the cranial vasculature of anaesthetized rabbits. 2. Thrombin (100 iu kg-1, i.c.) - induced platelet accumulation was completely abolished by pretreatment with desulphatohirudin (CGP 39393; 1 mg kg-1 i.c., 1 min prior to thrombin). Administration of CGP 39393 1 or 20 min after thrombin produced a significant reduction in platelet accumulation. 3. Intravenous (i.v.) administration of the platelet activating factor (PAF) receptor antagonist BN 52021 (10 mg kg-1) 5 min prior to thrombin (100 iu kg-1, i.c.) had no effect on platelet accumulation. 4. An inhibitor of NO biosynthesis, L-NG-nitro arginine methyl ester (L-NAME; 100 mg kg-1, i.c.), had no significant effect on the cranial platelet accumulation response to thrombin (10 iu kg-1, i.c.) when administered 5 min prior to thrombin. 5. Defibrotide (32 or 64 mg kg-1 bolus i.c. followed by 32 or 64 mg kg-1 h-1, i.c., infusion for 45 min) treatment begun 20 min after thrombin (100 iu kg-1, i.c.) did not significantly modify the cranial platelet accumulation response. 6. Cranial platelet accumulation induced by thrombin (100 iu kg-1, i.c.) was significantly reversed by the fibrinolytic drugs urokinase (20 iu kg-1, i.c., infusion for 45 min), anisoylated plasminogen streptokinase activator complex (APSAC) (200 micrograms kg-1, i.v. bolus) or recombinant tissue plasminogen activator (rt-PA; 100 micrograms kg-1, i.c. bolus followed by 20 micrograms kg-1 min-1, i.c., infusion for 45 min) administered 20 min after thrombin.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1504722

  10. Radionuclide blood cell survival studies

    International Nuclear Information System (INIS)

    Bentley, S.A.; Miller, D.T.

    1986-01-01

    Platelet and red cell survival studies are reviewed. The use of 51 Cr and di-isopropylfluoridate labelled with tritium or 32 P is discussed for red cell survival study and 51 Cr and 111 In-oxine are considered as platelet labels. (UK)

  11. In vitro detection of mdr1 mRNA in murine leukemia cells with 111In-labeled oligonucleotide

    International Nuclear Information System (INIS)

    Bai Jingming; Yokoyama, Kunihiko; Kinuya, Seigo; Michigishi, Takatoshi; Tonami, Norihisa; Shiba, Kazuhiro; Matsushita, Ryo; Nomura, Masaaki

    2004-01-01

    The feasibility of intracellular mdr1 mRNA expression detection with radiolabeled antisense oligonucleotide (ODN) was investigated in the murine leukemia cell line, P388/S, and its subclonal, adriamycin-resistant cell line, P388/R. The expression level of mdr1 mRNA was analyzed by reverse transcription-polymerase chain reaction (RT-PCR). Existence of the multidrug resistance (MDR) phenomenon was assessed via cellular uptake of 99m Tc-sestamibi (MIBI), a known substrate for P-glycoprotein. A 15-mer phosphorothioate antisense ODN complementary to the sequences located at -1 to 14 of mdr1 mRNA and its corresponding sense ODN were conjugated with the cyclic anhydride of diethylene triamine penta-acetic acid (cDTPA) via an amino group linked to the terminal phosphate at the 5' end at pH 8-9. The DTPA-ODN complexes at concentrations of 0.1-17.4 μMwere reacted with 111 InCl 3 at pH 5 for 1 h. The hybridization affinity of labeled ODN was evaluated with size-exclusion high-performance liquid chromatography following incubation with the complementary sequence. Cellular uptake of labeled ODN was examined in vitro. Furthermore, enhancing effects of synthetic lipid carriers (Transfast) on transmembrane delivery of ODN were assessed. P388/R cells displayed intense mdr1 mRNA expression in comparison with P388/S cells. 99m Tc-MIBI uptake in P388/S cells was higher than that in P388/R cells. Specific radioactivity up to 1,634 MBq/nmol was achieved via elevation of added radioactivity relative to ODN molar amount. The hybridization affinity of antisense 111 In-ODN was preserved at approximately 85% irrespective of specific activity. Cellular uptake of antisense 111 In-ODN did not differ from that of sense 111 In-ODN in either P388/S cells or P388/R cells. However, lipid carrier incorporation significantly increased transmembrane delivery of 111 In-ODN; moreover, specific uptake of antisense 111 In-ODN was demonstrated in P388/R cells. Radiolabeling of ODN at high specific

  12. Comparison between 67-gallium citrate of exametazine-T-99m labelled leucocites and the DTPA-indio-111 labelled G immunoglobuline in the diagnosis of bone and articular infections; Comparacion del citrato de galio-67 de los leucocitos marcados con exametazina-tecnecio-99m y de la inmunoglobulina G marcada con DTPA-indio-111 en el diagnostico de infecciones oseas y articulares

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Paulo Alberto de Lima [Departamento de Ciencias Basicas da Saude. Universidade Federal da Paraiba. Campina Grande (Brazil); Martin-Comin, Josep; Roca, Manel; Ricart, Ivone; Castell, Manuel; Mora, Jaume; Puchal, Rafael; Ramos, Miguel [Servicio de Medicina Nuclear, Hospital Princeps d' Espanya. Universidad de Barcelona. Feixa Llarga s/n, 08907. Barcelona (Spain)

    2000-01-01

    The aim of this study was to compare the ability of 67-Gallium citrate (67Ga), 99m-Tc labelled leucocytes (99mTc-WBC) and 111-In-labelled immunoglobulin G (111In-IgG) scintigraphy in bone and joint infections diagnosis. Fifty-six patients were studied. For all patients a bone scan using 99mTc-MDP was indicated. The patients were randomized allocated for 67Ga (Group 1 - 22 patients) or simultaneous administration 99mTc-labelled leucocytes and 111In-IgG.(Group 2 - 34 patients) study. For the groups 1 and 2 were confirmed respectively 12/26 y 11/34 septic lesions. The 67Ga scintigraphy showed 6 true-positive, 9 true-negative, 5 false-positive and 6 false-negative. With 99mTc-WBC, the respective values were 8, 18, 5 and 3. With 111In-IgG, the figures were 7, 17, 6 and 4, respectively. The sensitivity, specificity and accuracy were 50%, 64,3% and 57,7% respectively for the 67Ga, 72,7%, 78,2% and 76,4% respectively for 99mTc-WBC and 63,6%, 73,9% and 70,6% respectively for 111In-IgG. In this study, the labelled leucocytes scintigraphy showed more accurate than 67Ga and 111In-IgG scans for the diagnosis of bone and joint infections. However, the obtained results were less reliable for the diagnosis of occult sepsis in the patients with joint prosthesis (Au)

  13. Indium-111 chloride imaging in the detection of infected prostheses

    International Nuclear Information System (INIS)

    Sayle, B.A.; Fawcett, H.D.; Wilkey, D.J.; Cierny, G. III; Mader, J.T.

    1985-01-01

    Thirty-three patients with painful joint prostheses and a suspicion of infection were imaged with [ 111 In]chloride. A final diagnosis was established by culture in 19. Of these, 12 were categorized as true positives and three as true negatives. There were two false-positive studies, occurring in patients with knee prostheses. In both, the culture was obtained by aspiration. The sensitivity was 86%, specificity 60%, and accuracy 79%. Seventeen of the proven cases had bone imaging prior to [ 111 In]chloride imaging. All 17 static images were positive and were not helpful in differentiating loosening from infection. Using increased uptake on the blood-pool image as a criteria for infection, the sensitivity was 89%, but the specificity was 0. Adding flow studies made little difference in interpreting the blood-pool images. This study shows that [ 111 In]chloride imaging is more accurate in evaluating infection in prosthesis than bone imaging

  14. Improved labelling of DTPA- and DOTA-conjugated peptides and antibodies with 111In in HEPES and MES buffer.

    NARCIS (Netherlands)

    Brom, M.; Joosten, L.; Oyen, W.J.G.; Gotthardt, M.; Boerman, O.C.

    2012-01-01

    ABSTRACT: BACKGROUND: In single photon emission computed tomography [SPECT], high specific activity of 111In-labelled tracers will allow administration of low amounts of tracer to prevent receptor saturation and/or side effects. To increase the specific activity, we studied the effect of the buffer

  15. Flow cytometric and radioisotopic determinations of platelet survival time in normal cats and feline leukemia virus-infected cats

    International Nuclear Information System (INIS)

    Jacobs, R.M.; Boyce, J.T.; Kociba, G.J.

    1986-01-01

    This study demonstrates the potential usefulness of a flow cytometric technique to measure platelet survival time in cats utilizing autologous platelets labeled in vitro with fluorescein isothiocyanate (FITC). When compared with a 51Cr method, no significant differences in estimated survival times were found. Both the 51Cr and FITC-labeling procedures induced similar changes in platelet shape and collagen-induced aggregation. Platelets labeled with FITC had significantly greater volumes compared with those of glutaraldehyde-fixed platelets. These changes were primarily related to the platelet centrifugation and washing procedures rather than the labels themselves. This novel technique potentially has wide applicability to cell circulation time studies as flow cytometry equipment becomes more readily available. Problems with the technique are discussed. In a preliminary study of the platelet survival time in feline leukemia virus (FeLV)-infected cats, two of three cats had significantly reduced survival times using both flow cytometric and radioisotopic methods. These data suggest increased platelet turnover in FeLV-infected cats

  16. Flow cytometric and radioisotopic determinations of platelet survival time in normal cats and feline leukemia virus-infected cats

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, R.M.; Boyce, J.T.; Kociba, G.J.

    1986-01-01

    This study demonstrates the potential usefulness of a flow cytometric technique to measure platelet survival time in cats utilizing autologous platelets labeled in vitro with fluorescein isothiocyanate (FITC). When compared with a 51Cr method, no significant differences in estimated survival times were found. Both the 51Cr and FITC-labeling procedures induced similar changes in platelet shape and collagen-induced aggregation. Platelets labeled with FITC had significantly greater volumes compared with those of glutaraldehyde-fixed platelets. These changes were primarily related to the platelet centrifugation and washing procedures rather than the labels themselves. This novel technique potentially has wide applicability to cell circulation time studies as flow cytometry equipment becomes more readily available. Problems with the technique are discussed. In a preliminary study of the platelet survival time in feline leukemia virus (FeLV)-infected cats, two of three cats had significantly reduced survival times using both flow cytometric and radioisotopic methods. These data suggest increased platelet turnover in FeLV-infected cats.

  17. Theoretical Investigation on Structural and Electronic Properties of InN Growth on Ce-Stabilized Zirconia (111 Substrates

    Directory of Open Access Journals (Sweden)

    Yao Guo

    2016-01-01

    Full Text Available The structural and electronic properties of InN on Ce-stabilized zirconia (CeSZ (111 substrates are investigated using first-principles calculations based on density functional theory with GGA + U method. Surface energy calculations indicate that the structure of Ce-segregated surface is more energetically stable than that of Ce-segregation-free surface. Adsorption energies of indium and nitrogen atoms on both Ce-segregated and Ce-segregation-free CeSZ (111 surfaces at the initial growth stage have been studied. The results suggest that the first layer of InN films consists of a nitrogen layer, which leads to epitaxial relationships between InN (0001 // CeSZ (111 and InN [112¯0] // CeSZ [11¯0]. In addition, density of states (DOS analysis revealed that the hybridization effect plays a crucial role in determining the interface structure for the growth of InN on CeSZ (111 surfaces. Furthermore, adsorption energies of indium atoms on the nitrogen layer have also been evaluated in order to investigate the lattice polarity determination for InN films. It was found that an indium atom preferentially adsorbs at the center of three nitrogen atoms stacked on the CeSZ substrate, which results in the formation of In-polarity InN.

  18. Influence of thermal treatment in N{sub 2} atmosphere on chemical, microstructural and optical properties of indium tin oxide and nitrogen doped indium tin oxide rf-sputtered thin films

    Energy Technology Data Exchange (ETDEWEB)

    Stroescu, H.; Anastasescu, M.; Preda, S.; Nicolescu, M.; Stoica, M. [Institute of Physical Chemistry “Ilie Murgulescu” of the Romanian Academy, Spl. Independentei 202, 060021 Bucharest (Romania); Stefan, N. [National Institute for Lasers, Plasma and Radiation Physics, Atomistilor 409, RO-77125, Bucharest-Magurele (Romania); Kampylafka, V.; Aperathitis, E. [FORTH-IESL, Crete (Greece); Modreanu, M. [Tyndall National Institute, University College Cork, Cork (Ireland); Zaharescu, M. [Institute of Physical Chemistry “Ilie Murgulescu” of the Romanian Academy, Spl. Independentei 202, 060021 Bucharest (Romania); Gartner, M., E-mail: mgartner@icf.ro [Institute of Physical Chemistry “Ilie Murgulescu” of the Romanian Academy, Spl. Independentei 202, 060021 Bucharest (Romania)

    2013-08-31

    We report the influence of the normal thermal treatment (TT) and of rapid thermal annealing (RTA) on the microstructural, optical and electrical properties of indium tin oxide (ITO) and nitrogen doped indium tin oxide (ITO:N) thin films. The TT was carried out for 1 h at 400 °C and the RTA for 1 min up to 400 °C, both in N{sub 2} atmosphere. The ITO and ITO:N films were deposited by reactive sputtering in Argon, and respectively Nitrogen plasma, on Si with (100) and (111) orientation. The present study brings data about the microstructural and optical properties of ITO thin films with thicknesses around 300–400 nm. Atomic Force Microscopy analysis showed the formation of continuous and homogeneous films, fully covered by quasi-spherical shaped particles, with higher roughness values on Si(100) as compared to Si(111). Spectroscopic ellipsometry allowed the determination of film thickness, optical band gap as well as of the dispersion curves of n and k optical constants. X-ray diffraction analysis revealed the presence of diffraction peaks corresponding to the same nominal bulk composition of ITO, but with different intensities and preferential orientation depending on the substrate, atmosphere of deposition and type of thermal treatment. - Highlights: ► Stability of the films can be monitored by experimental ellipsometric spectra. ► The refractive index of indium tin oxide film on 0.3–30 μm range is reported. ► Si(100) substrate induces rougher film surfaces than Si(111). ► Rapid thermal annealing and normal thermal treatment lead to stable conductive film. ► The samples have a higher preferential orientation after rapid thermal annealing.

  19. Exchangeable splenic platelet pool in response to intravenous infusion of isoprenaline

    Energy Technology Data Exchange (ETDEWEB)

    Freden, K; Olsson, L B; Suurkula, M; Kutti, J

    1978-01-01

    8 healthy volunteers and 4 asplenic subjects, in whom autologous platelets had been labelled with radioactive sodium chromate, received intravenous infusions of isoprenaline in a dose of 0.03 ..mu..g x kg/sup -1/ x min/sup -1/ over a period of 6 min. In the former group these infusions caused a significant decrease in the concentration of labelled as well as unlabelled platelets in the peripheral blood. Body surface countings showed that a significant increase in the count rate over the spleen occurred concomitantly with the decrease in the circulating platelet-bound radioactivity (PBR). In the group of asplenic subjects no change in PBR occurred. It is concluded that adrenergic beta-receptor stimulation causes a transitory trapping of platelets in the exchangeable splenic platelet pool.

  20. Enhanced tumor retention of a radiohalogen label for site-specific modification of antibodies.

    Science.gov (United States)

    Boswell, C Andrew; Marik, Jan; Elowson, Michael J; Reyes, Noe A; Ulufatu, Sheila; Bumbaca, Daniela; Yip, Victor; Mundo, Eduardo E; Majidy, Nicholas; Van Hoy, Marjie; Goriparthi, Saritha N; Trias, Anthony; Gill, Herman S; Williams, Simon P; Junutula, Jagath R; Fielder, Paul J; Khawli, Leslie A

    2013-12-12

    A known limitation of iodine radionuclides for labeling and biological tracking of receptor targeted proteins is the tendency of iodotyrosine to rapidly diffuse from cells following endocytosis and lysosomal degradation. In contrast, radiometal-chelate complexes such as indium-111-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (In-111-DOTA) accumulate within target cells due to the residualizing properties of the polar, charged metal-chelate-amino acid adduct. Iodine radionuclides boast a diversity of nuclear properties and chemical means for incorporation, prompting efforts to covalently link radioiodine with residualizing molecules. Herein, we describe the Ugi-assisted synthesis of [I-125]HIP-DOTA, a 4-hydroxy-3-iodophenyl (HIP) derivative of DOTA, and demonstration of its residualizing properties in a murine xenograft model. Overall, this study displays the power of multicomponent synthesis to yield a versatile radioactive probe for antibodies across multiple therapeutic areas with potential applications in both preclinical biodistribution studies and clinical radioimmunotherapies.

  1. Indium-Nitrogen Codoped Zinc Oxide Thin Film Deposited by Ultrasonic Spray Pyrolysis on n-(111 Si Substrate: The Effect of Film Thickness

    Directory of Open Access Journals (Sweden)

    Cheng-Chang Yu

    2014-01-01

    Full Text Available Indium-nitrogen codoped zinc oxide (INZO thin films were fabricated by spray pyrolysis deposition technique on n-(111 Si substrate with different film thicknesses at 450°C using a precursor containing zinc acetate, ammonium acetate, and indium nitrate with 1 : 3 : 0.05 at.% concentration. The morphology and structure studies were carried out by scanning electron microscopy (SEM and X-ray diffraction (XRD. The grain size of the films increased when increasing the film thickness. From XRD spectra, polycrystalline ZnO structure can be observed and the preferred orientation behavior varied from (002 to (101 as the film thickness increased. The concentration and mobility were investigated by Hall effect measurement. the p-type films with a hole mobility around 3 cm2V−1s−1 and hole concentration around 3×1019 cm−3 can be achieved with film thickness less than 385 nm. The n-type conduction with concentration 1×1020 cm−3 is observed for film with thickness 1089 nm. The defect states were characterized by photoluminescence. With temperature-dependent conductivity analysis, acceptor state with activation energy 0.139 eV dominate the p type conduction for thin INZO film. And the Zn-related shallow donors with activation energy 0.029 eV dominate the n-type conduction for the thick INZO film.

  2. Precursors for formation of copper selenide, indium selenide, copper indium diselenide, and/or copper indium gallium diselenide films

    Science.gov (United States)

    Curtis, Calvin J; Miedaner, Alexander; Van Hest, Maikel; Ginley, David S

    2014-11-04

    Liquid-based precursors for formation of Copper Selenide, Indium Selenide, Copper Indium Diselenide, and/or copper Indium Galium Diselenide include copper-organoselenides, particulate copper selenide suspensions, copper selenide ethylene diamine in liquid solvent, nanoparticulate indium selenide suspensions, and indium selenide ethylene diamine coordination compounds in solvent. These liquid-based precursors can be deposited in liquid form onto substrates and treated by rapid thermal processing to form crystalline copper selenide and indium selenide films.

  3. Phase I trial of yttrium-90-labeled anti-prostate-specific membrane antigen monoclonal antibody J591 for androgen-independent prostate cancer.

    Science.gov (United States)

    Milowsky, Matthew I; Nanus, David M; Kostakoglu, Lale; Vallabhajosula, Shankar; Goldsmith, Stanley J; Bander, Neil H

    2004-07-01

    To determine the maximum-tolerated dose (MTD), toxicity, human antihuman antibody (HAHA) response, pharmacokinetics, organ dosimetry, targeting, and preliminary efficacy of yttrium-90-labeled anti-prostate-specific membrane antigen monoclonal antibody J591 ((90)Y-J591) in patients with androgen-independent prostate cancer (PC). Patients with androgen-independent PC and evidence of disease progression received indium-111-J591 for pharmacokinetic and biodistribution determinations followed 1 week later by (90)Y-J591 at five dose levels: 5, 10, 15, 17.5, and 20 mCi/m(2). Patients were eligible for up to three re-treatments if platelet and neutrophil recovery was satisfactory. Twenty-nine patients with androgen-independent PC received (90)Y-J591, four of whom were re-treated. Dose limiting toxicity (DLT) was seen at 20 mCi/m(2), with two patients experiencing thrombocytopenia with non-life-threatening bleeding episodes requiring platelet transfusions. The 17.5-mCi/m(2) dose level was determined to be the MTD. No re-treated patients experienced DLT. Nonhematologic toxicity was not dose limiting. Targeting of known sites of bone and soft tissue metastases was seen in the majority of patients. No HAHA response was seen. Antitumor activity was seen, with two patients experiencing 85% and 70% declines in prostate-specific antigen (PSA) levels lasting 8 and 8.6 months, respectively, before returning to baseline. Both patients had objective measurable disease responses. An additional six patients (21%) experienced PSA stabilization. The recommended dose for (90)Y-J591 is 17.5 mCi/m(2). Acceptable toxicity, excellent targeting of known sites of PC metastases, and biologic activity in patients with androgen-independent PC warrant further investigation of (90)Y-J591 in the treatment of patients with PC.

  4. Effects of the amino acid linkers on the melanoma-targeting and pharmacokinetic properties of 111In-labeled lactam bridge-cyclized alpha-MSH peptides.

    Science.gov (United States)

    Guo, Haixun; Yang, Jianquan; Gallazzi, Fabio; Miao, Yubin

    2011-04-01

    The purpose of this study was to examine the profound effects of the amino acid linkers on the melanoma-targeting and pharmacokinetic properties of (111)In-labeled lactam bridge-cyclized DOTA-[X]-CycMSH(hex) {1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid-[X]-c[Asp-His-dPhe-Arg-Trp-Lys]-CONH(2); X = GGNle, GENle, or NleGE; GG = -Gly-Gly- and GE = -Gly-Glu-} peptides. Three novel peptides (DOTA-GGNle-CycMSH(hex), DOTA-GENle-CycMSH(hex), and DOTA-NleGE-CycMSH(hex)) were designed and synthesized. The melanocortin-1 (MC1) receptor-binding affinities of the peptides were determined in B16/F1 melanoma cells. The melanoma-targeting and pharmacokinetic properties of (111)In-DOTA-GGNle-CycMSH(hex) and (111)In-DOTA-GENle-CycMSH(hex) were determined in B16/F1 melanoma-bearing C57 mice. DOTA-GGNle-CycMSH(hex) and DOTA-GENle-CycMSH(hex) displayed 2.1 and 11.5 nM MC1 receptor-binding affinities, whereas DOTA-NleGE-CycMSH(hex) showed 873.4 nM MC1 receptor-binding affinity. The introduction of the -GG- linker maintained high melanoma uptake while decreasing kidney and liver uptake of (111)In-DOTA-GGNle-CycMSH(hex). The tumor uptake of (111)In-DOTA-GGNle-CycMSH(hex) was 19.05 ± 5.04 and 18.6 ± 3.56 percentage injected dose per gram at 2 and 4 h after injection, respectively. (111)In-DOTA-GGNle-CycMSH(hex) exhibited 28%, 32%, and 42% less kidney uptake than (111)In-DOTA-Nle-CycMSH(hex) we reported previously, and 61%, 65%, and 68% less liver uptake than (111)In-DOTA-Nle-CycMSH(hex) at 2, 4, and 24 h after injection, respectively. The amino acid linkers exhibited profound effects on the melanoma-targeting and pharmacokinetic properties of the (111)In-labeled lactam bridge-cyclized α-melanocyte-stimulating hormone peptides. Introduction of the -GG- linker maintained high melanoma uptake while reducing kidney and liver uptake of (111)In-DOTA-GGNle-CycMSH(hex), highlighting its potential as an effective imaging probe for melanoma detection, as well as a therapeutic peptide

  5. New methods of sup(111)In chemical separation

    International Nuclear Information System (INIS)

    Santos, D.F.; Osso Junior, J.A.; Bastos, M.A.V.; Britto, J.L.Q.; Silva, R.F.

    1986-01-01

    The cation exchange and thermochromatography methods for chemical separation of sup(111) In from silver targets are described. The cation exchange method is based on the difference between In and Ag distribution coefficients on cation exchange resin treated with HNO sub(3). The thermochromatography consists of indium diffusion on silver melted after sublimation and posterior condensation. (M.C.K.)

  6. Influence of macrocyclic chelators on the targeting properties of (68Ga-labeled synthetic affibody molecules: comparison with (111In-labeled counterparts.

    Directory of Open Access Journals (Sweden)

    Joanna Strand

    Full Text Available Affibody molecules are a class of small (7 kDa non-immunoglobulin scaffold-based affinity proteins, which have demonstrated substantial potential as probes for radionuclide molecular imaging. The use of positron emission tomography (PET would further increase the resolution and quantification accuracy of Affibody-based imaging. The rapid in vivo kinetics of Affibody molecules permit the use of the generator-produced radionuclide (68Ga (T1/2=67.6 min. Earlier studies have demonstrated that the chemical nature of chelators has a substantial influence on the biodistribution properties of Affibody molecules. To determine an optimal labeling approach, the macrocyclic chelators 1,4,7,10-tetraazacylododecane-1,4,7,10-tetraacetic acid (DOTA, 1,4,7-triazacyclononane-N,N,N-triacetic acid (NOTA and 1-(1,3-carboxypropyl-1,4,7- triazacyclononane-4,7-diacetic acid (NODAGA were conjugated to the N-terminus of the synthetic Affibody molecule ZHER2:S1 targeting HER2. Affibody molecules were labeled with (68Ga, and their binding specificity and cellular processing were evaluated. The biodistribution of (68Ga-DOTA-ZHER2:S1, (68Ga-NOTA-ZHER2:S1 and (68Ga-NODAGA-ZHER2:S1, as well as that of their (111In-labeled counterparts, was evaluated in BALB/C nu/nu mice bearing HER2-expressing SKOV3 xenografts. The tumor uptake for (68Ga-DOTA-ZHER2:S1 (17.9 ± 0.7%IA/g was significantly higher than for both (68Ga-NODAGA-ZHER2:S1 (16.13 ± 0.67%IA/g and (68Ga-NOTA-ZHER2:S1 (13 ± 3%IA/g at 2 h after injection. (68Ga-NODAGA-ZHER2:S1 had the highest tumor-to-blood ratio (60 ± 10 in comparison with both (68Ga-DOTA-ZHER2:S1 (28 ± 4 and (68Ga-NOTA-ZHER2:S1 (42 ± 11. The tumor-to-liver ratio was also higher for (68Ga-NODAGA-ZHER2:S1 (7 ± 2 than the DOTA and NOTA conjugates (5.5 ± 0.6 vs.3.3 ± 0.6. The influence of chelator on the biodistribution and targeting properties was less pronounced for (68Ga than for (111In. The results of this study demonstrate that macrocyclic

  7. Indium111 antimyosin for the detection of leiomyosarcoma and rhabdomyosarcoma

    International Nuclear Information System (INIS)

    Cox, P.H.; Pillay, M.; Schonfeld, D.; Verweij, J.; Stoter, G.

    1988-01-01

    111 In-antimyosin monoclonal antibody complex passes through damaged myocardial cell membranes and binds to the intracellular myosin. Normal myocardial and other muscle cells show no uptake. Rhabdomyosarcoma and Leiomyosarcoma cells also contain intracellular myosin and the cell membrane permeability is greater than normal. Significant uptake of 111 In-antimyosin was observed in patients with Leiomyosarcoma and Rhabdomyosarcoma suggesting that the reagent has a potential for the in vivo detection of these tumour types. Tumour to background ratios of 10:1 were measured in one case and in view of the fact that the site of accumulation is intracellular, antimyosin may have a potential as a carrier for therapeutic agents. (orig.)

  8. Scintigraphy with /sup 111/In-labeled antimyosin F(ab)/sub 2/ monoclonal antibody and /sup 99m/Tc-pyrophosphate in rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Krause, T.; Schuemichen, C.; Hohenloser, S.; Kasper, W.; Meinertz, T.

    1988-02-01

    A report is presented of the scintigraphic diagnosis of a generalized rhabdomyolysis with myocardial involvement using /sup 111/In labelled antimyosin F(ab)/sub 2/ monoclonal antibodies as compared to /sup 99m/Tc pyrophosphate.

  9. Formation of copper-indium-selenide and/or copper-indium-gallium-selenide films from indium selenide and copper selenide precursors

    Science.gov (United States)

    Curtis, Calvin J [Lakewood, CO; Miedaner, Alexander [Boulder, CO; Van Hest, Maikel [Lakewood, CO; Ginley, David S [Evergreen, CO; Nekuda, Jennifer A [Lakewood, CO

    2011-11-15

    Liquid-based indium selenide and copper selenide precursors, including copper-organoselenides, particulate copper selenide suspensions, copper selenide ethylene diamine in liquid solvent, nanoparticulate indium selenide suspensions, and indium selenide ethylene diamine coordination compounds in solvent, are used to form crystalline copper-indium-selenide, and/or copper indium gallium selenide films (66) on substrates (52).

  10. Thrombus imaging in a primate model with antibodies specific for an external membrane protein of activated platelets

    International Nuclear Information System (INIS)

    Palabrica, T.M.; Furie, B.C.; Konstam, M.A.; Aronovitz, M.J.; Connolly, R.; Brockway, B.A.; Ramberg, K.L.; Furie, B.

    1989-01-01

    The activated platelet is a potential target for the localization of thrombi in vivo since, after stimulation and secretion of granule contents, activated platelets are concentrated at sites of blood clot formation. In this study, we used antibodies specific for a membrane protein of activated platelets to detect experimental thrombi in an animal model. PADGEM (platelet activation-dependent granule-external membrane protein), a platelet alpha-granule membrane protein, is translocated to the plasma membrane during platelet activation and granule secretion. Since PADGEM is internal in unstimulated platelets, polyclonal anti-PADGEM and monoclonal KC4 antibodies do not bind to circulating resting platelets but do interact with activated platelets. Dacron graft material incubated with radiolabeled KC4 or anti-PADGEM antibodies in the presence of thrombin-activated platelet-rich plasma bound most of the antibody. Imaging experiments with 123I-labeled anti-PADGEM in baboons with an external arterial-venous Dacron shunt revealed rapid uptake in the thrombus induced by the Dacron graft; control experiments with 123I-labeled nonimmune IgG exhibited minimal uptake. Deep venous thrombi, formed by using percutaneous balloon catheters to stop blood flow in the femoral vein of baboons, were visualized with 123I-labeled anti-PADGEM. Thrombi were discernible against blood pool background activity without subtraction techniques within 1 hr. No target enhancement was seen with 123I-labeled nonimmune IgG. 123I-labeled anti-PADGEM cleared the blood pool with an initial half-disappearance time of 6 min and did not interfere with hemostasis. These results indicate that radioimmunoscintigraphy with anti-PADGEM antibodies can visualize thrombi in baboon models and is a promising technique for clinical thrombus detection in humans

  11. Radiation dose calculations for orally administered radio-pharmaceuticals in upper gastrointestinal disease

    International Nuclear Information System (INIS)

    Wu, R.K.; Malmud, L.S.; Knight, L.C.; Siegel, J.A.; Stern, H.; Zelac, R.

    1983-01-01

    Radiation burden estimates for upper gastrointestinal function studies employing the following orally administered radiopharmaceuticals are reported. Technetium 99m sulfur colloid (Tc-99m-SC) in water, Indium-111-DTPA in water, Tc-99m-DTPA in water, Indium-113m DTPA in water, Tc-99m Ovalbumin, Tc-99m sulfur colloid in a cooked egg, Tc-99m sulfur colloid in vivo labeled chicken liver, and Indium-111 colloid in vivo labeled chicken liver. Orally administered radiopharmaceuticals for upper gastrointestinal studies afford clinician and investigator valuable clinical and physiologic information not previously obtainable using other techniques. The radiation burden to the patient from single or sequential studies is acceptable in comparison to fluoroscopy which results in approximately 5000 millirem per minute of exposure. The variety of preparations listed above should make these types of studies available in any routinely equipped nuclear medicine radiopharmacy laboratory

  12. Glycoprotein biosynthesis by human normal platelets

    International Nuclear Information System (INIS)

    Rodriguez, P.; Bello, O.; Apitz-Castro, R.

    1987-01-01

    Incorporation of radioactive Man, Gal, Fuc, Glc-N, and NANA into washed human normal platelets and endogenous glycoproteins has been found. Both parameters were time dependent. Analysis of hydrolyzed labeled glycoproteins by paper chromatography revealed that the radioactive monosaccharide incubated with the platelets had not been converted into other sugars. Acid hydrolysis demonstrates the presence of a glycosidic linkage. All the effort directed to the demonstration of the existence of a lipid-sugar intermediate in intact human platelets yielded negative results for Man and Glc-N used as precursors. The incorporation of these sugars into glycoproteins is insensitive to bacitracin, suggesting no involvement of lipid-linked saccharides in the synthesis of glycoproteins in human blood platelets. The absence of inhibition of the glycosylation process in the presence of cycloheximide suggests that the sugars are added to proteins present in the intact platelets. These results support the contention that glycoprotein biosynthesis in human blood platelets observed under our experimental conditions is effected through direct sugar nucleotide glycosylation

  13. Development of 111In-DTPA-human polyclonal antibody complex for long-term inflammation/infection detection

    International Nuclear Information System (INIS)

    Jalilian, A.R.; Rowshanfarzad, P.; Kamali-Dehghan, M.; Moafian, J.; Akhlaghi, M.; Rajabifar, S.; Mirzaii, M.; Shafaii, K.; Babaii, M.

    2005-01-01

    Human polyclonal antibody (HIgG) was successively labeled with 111-indium chloride after residulation with freshly prepared cyclic DTPA-dianhydride. The best results of the conjugation were obtained by the addition of solid DTPA-dianhydride (0.1-0.3 mg) to 100 μl of the HIgG solution (0.2-0.4 mg/ml) at pH = 6 in phosphate buffer media at 25 o C with continuous stirring for 30 min. Radio-thin-layer chromatography showed an overall radiochemical yield of 96-99% at optimized conditions (specific activity = 300-500 MBq/mg, radiochemical purity >98%). The final isotonic 111 In-DTPA-HIgG complex was checked by radio-TLC to ensure the formation of only one species followed by filtration through a 0.22 μ filter. Preliminary long-term in vivo studies in turpentine-oil induced inflammation in rat model was performed to determine late complex distribution of the radioimmunoconjugate. The target/skin and target/blood ratios were 27 and 51 after 24 h, and 23 and 51 after 110 h, showing a high selectivity of the radiopharmaceutical for inflammatory lesions. (author)

  14. Quantitative Assessment of Myocardial Infarction by In-111 Antimyosin Antibody

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Chul; Lee, Kyung Han; Choi, Yoon Ho; Chung, June Key; Park, Young Bae; Koh, Chang Soon [Seoul National University College of Medicine, Seoul (Korea, Republic of); Moon, Dae Hyuk [Asan Medical Center, Ulsan University College of Medicine, Seoul (Korea, Republic of)

    1991-03-15

    Infarct size is a major determinant of prognosis after acute myocardial infarction. Up to date, however, clinically available tests to estimate this size have not been sufficiently accurate. Twelve lead electrocardiogram and wall motion abnormality measurement are not quantitative, and creatine phosphokinase (CPK) measurement is inaccurate in the presence of reperfusion or right ventricular infarction. Methods have been developed to localize and size acute myocardial infarcts with agents that are selectively sequestered in areas of myocardial damage, but previously used agents have lacked sufficient specificity. Antibodies that bind specifically only to damaged myocardial cells may resolve this problem and provide an accurate method for noninvasively measuring infarct size. We determined the accuracy with which infarcted myocardial mass can be measured using single photon emission computed tomography (SPECT) and radiolabeled antimyosin antibodies. Seven patients with acute myocardial infarction and one stable angina patient were injected with 2 mCi of Indium-111 labeled antimyosin antibodies. Planar image and SPECT was performed 24 hours later. None of the patients had history of prior infarcts, and none had undergone reperfusion techniques prior to the study, which was done within 4 days of the attack. Planar image showed all infarct patients to have positive uptakes in the cardiac region. The location of this uptake correlated to the infarct site as indicated by electrocardiography in most of the cases. The angina patient, however, showed no such abnormal uptake. Infarct size was determined from transverse slices of the SPECT image using a 45% threshold value obtained from a phantom study. Measured infarct size ranged from 40 to 192 gr. There was significant correlation between the infarct size measured by SPECT and that estimated from serial measurements of CPK (r=0.73, p<0,05). These date suggest that acute myocardial infarct size can be accurately measured

  15. Pharmacokinetic analysis of 111 in-labeled liposomal Doxorubicin in murine glioblastoma after blood-brain barrier disruption by focused ultrasound.

    Directory of Open Access Journals (Sweden)

    Feng-Yi Yang

    Full Text Available The goal of this study was to evaluate the pharmacokinetics of targeted and untargeted (111In-doxorubicin liposomes after these have been intravenously administrated to tumor-bearing mice in the presence of blood-brain barrier disruption (BBB-D induced by focused ultrasound (FUS. An intracranial brain tumor model in NOD-scid mice using human brain glioblastoma multiforme (GBM 8401 cells was developed in this study. (111In-labeled human atherosclerotic plaque-specific peptide-1 (AP-1-conjugated liposomes containing doxorubicin (Lipo-Dox; AP-1 Lipo-Dox were used as a microSPECT probe for radioactivity measurements in the GBM-bearing mice. Compared to the control tumors treated with an injection of (111In-AP-1 Lipo-Dox or (111In-Lipo-Dox, the animals receiving the drugs followed by FUS exhibited enhanced accumulation of the drug in the brain tumors (p<0.05. Combining sonication with drugs significantly increased the tumor-to-normal brain doxorubicin ratio of the target tumors compared to the control tumors. The tumor-to-normal brain ratio was highest after the injection of (111In-AP-1 Lipo-Dox with sonication. The (111In-liposomes micro-SPECT/CT should be able to provide important information about the optimum therapeutic window for the chemotherapy of brain tumors using sonication.

  16. Selective elution of HLA antigens and beta 2-microglobulin from human platelets by chloroquine diphosphate

    International Nuclear Information System (INIS)

    Kao, K.J.

    1988-01-01

    To determine whether chloroquine can specifically elute HLA antigens and beta 2-microglobulin (beta 2-M) from the platelet surface, quantitative immunofluorescence flow cytometry and monoclonal antibodies were used to show that HLA antigens and beta 2-M were proportionally eluted from the platelet surface without affecting the membrane glycoproteins IIb and IIIa. Second, an autoradiogram of electrophoresed I-125-labeled platelets showed that only beta 2-M but not other I-125-labeled membrane proteins could be eluted. Although HLA antigens were poorly labeled by I-125 and could not be detected on the autoradiogram, the eluted HLA antigens could be detected by anti-HLA monoclonal antibody and immunoblotting techniques. No loss of plasma membrane integrity was observed by transmission electron microscopy after chloroquine treatment of platelets. The results indicate that chloroquine selectively elutes HLA antigens and their noncovalently associated beta 2-M without affecting other integral platelet membrane proteins

  17. The use of spinning-disk confocal microscopy for the intravital analysis of platelet dynamics in response to systemic and local inflammation.

    Directory of Open Access Journals (Sweden)

    Craig N Jenne

    Full Text Available Platelets are central players in inflammation and are an important component of the innate immune response. The ability to visualize platelets within the live host is essential to understanding their role in these processes. Past approaches have involved adoptive transfer of labelled platelets, non-specific dyes, or the use of fluorescent antibodies to tag platelets in vivo. Often, these techniques result in either the activation of the platelet, or blockade of specific platelet receptors. In this report, we describe two new methods for intravital visualization of platelet biology, intravenous administration of labelled anti-CD49b, which labels all platelets, and CD41-YFP transgenic mice, in which a percentage of platelets express YFP. Both approaches label endogenous platelets and allow for their visualization using spinning-disk confocal fluorescent microscopy. Following LPS-induced inflammation, we were able to measure a significant increase in both the number and size of platelet aggregates observed within the vasculature of a number of different tissues. Real-time observation of these platelet aggregates reveals them to be large, dynamic structures that are continually expanding and sloughing-off into circulation. Using these techniques, we describe for the first time, platelet recruitment to, and behaviour within numerous tissues of the mouse, both under control conditions and following LPS induced inflammation.

  18. Recent developments in blood cell labeling research

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, S.C.; Straub, R.F.; Meinken, G.E.

    1988-09-07

    A number of recent developments in research on blood cell labeling techniques are presented. The discussion relates to three specific areas: (1) a new in vitro method for red blood cell labeling with /sup 99m/Tc; (2) a method for labeling leukocytes and platelets with /sup 99m/Tc; and (3) the use of monoclonal antibody technique for platelet labeling. The advantages and the pitfalls of these techniques are examined in the light of available mechanistic information. Problems that remain to be resolved are reviewed. An assessment is made of the progress as well as prospects in blood cell labeling methodology including that using the monoclonal antibody approach. 37 refs., 4 figs.

  19. Recent developments in blood cell labeling research

    International Nuclear Information System (INIS)

    Srivastava, S.C.; Straub, R.F.; Meinken, G.E.

    1988-01-01

    A number of recent developments in research on blood cell labeling techniques are presented. The discussion relates to three specific areas: (1) a new in vitro method for red blood cell labeling with /sup 99m/Tc; (2) a method for labeling leukocytes and platelets with /sup 99m/Tc; and (3) the use of monoclonal antibody technique for platelet labeling. The advantages and the pitfalls of these techniques are examined in the light of available mechanistic information. Problems that remain to be resolved are reviewed. An assessment is made of the progress as well as prospects in blood cell labeling methodology including that using the monoclonal antibody approach. 37 refs., 4 figs

  20. A review of the world market of indium (Economy of indium)

    International Nuclear Information System (INIS)

    Naumov, A.V.

    2005-01-01

    A review of the current state of the world and Russian markets of indium and indium-containing products was made based on the publications of the last years. Main fields of indium application are given, in particular, its using for neutron absorbing regulating rods in nuclear reactors. The second γ-radiation resulted from neutron absorption allows using indium as a neutron detector. Indium market stabilization is expected due to supply from China and South Korea [ru