WorldWideScience

Sample records for include all-electric operation

  1. 30 CFR 75.503-1 - Statement listing all electric face equipment.

    Science.gov (United States)

    2010-07-01

    ... all electric face equipment being used at each mine as of the time of filing, all such equipment being... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Statement listing all electric face equipment...-General § 75.503-1 Statement listing all electric face equipment. Each operator of a coal mine shall...

  2. Advanced electrical power system technology for the all electric aircraft

    Science.gov (United States)

    Finke, R. C.; Sundberg, G. R.

    1983-01-01

    The application of advanced electric power system technology to an all electric airplane results in an estimated reduction of the total takeoff gross weight of over 23,000 pounds for a large airplane. This will result in a 5 to 10 percent reduction in direct operating costs (DOC). Critical to this savings is the basic electrical power system component technology. These advanced electrical power components will provide a solid foundation for the materials, devices, circuits, and subsystems needed to satisfy the unique requirements of advanced all electric aircraft power systems. The program for the development of advanced electrical power component technology is described. The program is divided into five generic areas: semiconductor devices (transistors, thyristors, and diodes); conductors (materials and transmission lines); dielectrics; magnetic devices; and load management devices. Examples of progress in each of the five areas are discussed. Bipolar power transistors up to 1000 V at 100 A with a gain of 10 and a 0.5 microsec rise and fall time are presented. A class of semiconductor devices with a possibility of switching up to 100 kV is described. Solid state power controllers for load management at 120 to 1000 V and power levels to 25 kW were developed along with a 25 kW, 20 kHz transformer weighing only 3.2 kg. Previously announced in STAR as N83-24764

  3. Advanced electrical power system technology for the all electric aircraft

    Science.gov (United States)

    Finke, R. C.; Sundberg, G. R.

    1983-01-01

    The application of advanced electric power system technology to an all electric airplane results in an estimated reduction of the total takeoff gross weight of over 23,000 pounds for a large airplane. This will result in a 5 to 10 percent reduction in direct operating costs (DOC). Critical to this savings is the basic electrical power system component technology. These advanced electrical power components will provide a solid foundation for the materials, devices, circuits, and subsystems needed to satisfy the unique requirements of advanced all electric aircraft power systems. The program for the development of advanced electrical power component technology is described. The program is divided into five generic areas: semiconductor devices (transistors, thyristors, and diodes); conductors (materials and transmission lines); dielectrics; magnetic devices; and load management devices. Examples of progress in each of the five areas are discussed. Bipolar power transistors up to 1000 V at 100 A with a gain of 10 and a 0.5 microsec rise and fall time are presented. A class of semiconductor devices with a possibility of switching up to 100 kV is described. Solid state power controllers for load management at 120 to 1000 V and power levels to 25 kW were developed along with a 25 kW, 20 kHz transformer weighing only 3.2 kg.

  4. Electric shovels meet the demands for mining operations

    Energy Technology Data Exchange (ETDEWEB)

    Fiscor, S.

    2008-03-15

    Rugged, intelligent shovels offer better productivity and help mine operators avoid costly downtime in a very tight market. In 2007 P & H Mining Equipment began to produce a new breed of electric mining shovels designed to help reduce operating cost in coal and other mining operations. These were designated the P & H C-Series. All have an advanced communication, command and control system called the Centurion system. Coal mining applications for this series include 4100XPCs in Australia, China and Wyoming, USA. The Centurion system provides information on shovel performance and systems health which is communicated via graphic user interface terminals to the operators cab. Bucyrus International is developing a hydraulic crowd mechanism for its electric shovels and is now field testing one for its 495 series shovel. The company has also added greater capability in the primary software in the drive system for troubleshooting and fault identification to quickly diagnose problems onboard or remotely. 4 photos.

  5. Comparison of all-electric secondary power systems for civil transport

    Science.gov (United States)

    Renz, David D.

    1992-01-01

    Three separate studies have shown operational, weight, and cost advantages for commercial subsonic transport aircraft using an all-electric secondary power system. The first study in 1982 showed that all-electric secondary power systems produced the second largest benefit compared to four other technology upgrades. The second study in 1985 showed a 10 percent weight and fuel savings using an all-electric high frequency (20 kHz) secondary power system. The last study in 1991 showed a 2 percent weight savings using today's technology (400 Hz) in an all-electric secondary power system. This paper will compare the 20 kHz and 400 Hz studies, analyze the 2 to 10 percent difference in weight savings and comment on the common benefits of the all-electric secondary power system.

  6. Study on a New Operational Mode of Economic Operation of Islanded Microgrids Using Electric Springs

    Directory of Open Access Journals (Sweden)

    Zhao Zhiyu

    2018-01-01

    Full Text Available With the increasing penetration of intermittent renewable energy sources (RESs into microgrids, the original operation mode of power generation determined by load demand faces severe challenges due to the uncertainties of the RESs power output. The electric springs(ESs, as an emerging technology has been verified to be effective in enabling load demand to follow power generation and stabilizing fluctuation of RESs output. This paper presents a new mode of economic operation for island microgrids including non-critical loads with embedded electric springs. Its connotation includes that i the capacity of energy storage can be reduced through the interaction of the energy storage system (ESS and the electric springs, ii the electric springs reduce the stress of peak load regulation and operational cost and iii the demand of microgrids system for ramping ability of generation units is reduced with the buffer of the electric springs. Numerical results show that the coordinated operation between electric springs and energy storage system of microgrids can bring down the investment cost for the ESS and short-term operational cost in the aspect of economic dispatch, reducing requirements for the capacity and ramp ability of the energy storage system in microgrids. Energy buffering can be achieved with lower cost and the load demand can follow power generation in the new operational mode of islanded microgrids using electric springs.

  7. Comparison of all-electric secondary power systems for civil subsonic transports

    Science.gov (United States)

    Renz, David D.

    1992-01-01

    Three separate studies have shown operational, weight, and cost advantages for commercial subsonic transport aircraft using an all-electric secondary power system. The first study in 1982 showed that all-electric secondary power systems produced the second largest benefit compared to four other technology upgrades. The second study in 1985 showed a 10 percent weight and fuel savings using an all-electric high frequency (20 kHz) secondary power system. The last study in 1991 showed a 2 percent weight savings using today's technology (400 Hz) in an all-electric secondary power system. This paper will compare the 20 kHz and 400 Hz studies, analyze the 2 to 10 percent difference in weight savings and comment on the common benefits of the all-electric secondary power system.

  8. Space Weather Concerns for All-Electric Propulsion Satellites

    Science.gov (United States)

    Horne, Richard B.; Pitchford, David

    2015-08-01

    The introduction of all-electric propulsion satellites is a game changer in the quest for low-cost access to space. It also raises new questions for satellite manufacturers, operators, and the insurance industry regarding the general risks and specifically the threat of adverse space weather. The issues surrounding this new concept were discussed by research scientists and up to 30 representatives from the space industry at a special meeting at the European Space Weather Week held in November 2014. Here we report on the discussions at that meeting. We show that for a satellite undergoing electric orbit raising for 200 days the radiation dose due to electrons is equivalent to approximately 6.7 year operation at geostationary orbit or approximately half the typical design life. We also show that electrons can be injected into the slot region (8000 km) where they pose a risk of satellite internal charging. The results highlight the importance of additional radiation protection. We also discuss the benefits, the operational considerations, the other risks from the Van Allen radiation belts, the new business opportunities for space insurance, and the need for space situation awareness in medium Earth orbit where electric orbit raising takes place.

  9. Procedure for estimating nonfuel operation and maintenance costs for large steam-electric power plants

    International Nuclear Information System (INIS)

    Myers, M.L.; Fuller, L.C.

    1979-01-01

    Revised guidelines are presented for estimating annual nonfuel operation and maintenance costs for large steam-electric power plants, specifically light-water-reactor plants and coal-fired plants. Previous guidelines were published in October 1975 in ERDA 76-37, a Procedure for Estimating Nonfuel Operating and Maintenance Costs for Large Steam-Electric Power Plants. Estimates for coal-fired plants include the option of limestone slurry scrubbing for flue gas desulfurization. A computer program, OMCOST, is also presented which covers all plant options

  10. Scenario-based electric bus operation: A case study of Putrajaya, Malaysia

    Directory of Open Access Journals (Sweden)

    Lay Eng Teoh

    2018-03-01

    Full Text Available Globally, transportation sector has emerged as one of the major sources of air pollution. Correspondingly, green mobility (with electric bus is gaining increasing attention as an essential step to mitigate emission concern. As such, a proper electric bus network design and fleet planning is important especially for bus operator to acquire an adequate number of electric bus, right on time, in order to operate electric bus system viably. Thus, this paper aims to examine the possibility to operate electric bus as a replacement for the conventional bus operation (with natural gas buses for the study area in Putrajaya, Malaysia. In order to determine a proper-designed electric bus operating system in terms of electric bus route, service frequency and quantity, the proposed methodology is developed with the aid of a traffic modeling software to cater various scenarios. Based on the existing (conventional traffic and transit system in Putrajaya, the developed electric bus operating model is calibrated accordingly by considering various operational concerns including battery capacity and charging facility. The resultant findings revealed that the developed electric bus operating system in Putrajaya outperforms the conventional bus operation, not only in generating a higher profit margin for the bus operator, but also satisfying the passengers in a better manner (by carrying more passengers per unit of bus with a lower energy consumption.

  11. Optimal control strategy design for extending all-electric driving capability of plug-in hybrid electric vehicles (PHEVs)

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, S.S [Concordia Univ., Montreal, PQ (Canada). Dept. of Electrical and Computer Engineering, P.D Ziogas Power Electronics Laboratory

    2007-07-01

    The high voltage energy storage system in plug-in hybrid electric vehicles (PHEVs) is usually a rechargeable type that service a dual purpose, notably to supplement the power delivered by the internal combustion engine, and to provide partial propulsion energy from an off-board source of electricity. The energy storage devices in electric vehicles typically improve vehicle efficiency through engine downsizing and by recapturing braking energy. However, since PHEVs have the ability to recharge their energy storage systems directly from the power grid, the periods of all-electric operation can be extended, thereby reducing the dependence on the internal combustion engine. This is particularly useful in city driving conditions. Developers of PHEV technology are faced with the challenge of choosing the appropriate energy storage battery in order to improve the all-electric drive range. In this study, control strategies were modeled for specific driving load conditions using the Advanced Vehicle Simulator (ADVISOR) software. This paper presented specific control algorithms for PHEV operation for various city driving loads. The optimal design strategy considered the improvement of critical energy storage parameters, overall drive train efficiency, and vehicle performance characteristics. Future trends in the design and development of PHEV drive trains were also presented. 13 figs.

  12. Electric Power Monthly, August 1990. [Glossary included

    Energy Technology Data Exchange (ETDEWEB)

    1990-11-29

    The Electric Power Monthly (EPM) presents monthly summaries of electric utility statistics at the national, Census division, and State level. The purpose of this publication is to provide energy decisionmakers with accurate and timely information that may be used in forming various perspectives on electric issues that lie ahead. Data includes generation by energy source (coal, oil, gas, hydroelectric, and nuclear); generation by region; consumption of fossil fuels for power generation; sales of electric power, cost data; and unusual occurrences. A glossary is included.

  13. 46 CFR 113.35-7 - Electric engine order telegraph systems; operations.

    Science.gov (United States)

    2010-10-01

    ... transmitter handle automatically connects that transmitter electrically to the engineroom indicator and simultaneously disconnects electrically all other transmitters. The reply pointers of all transmitters must... manually operated transfer switch which will disconnect the system in the unattended navigating bridge must...

  14. Scenarios for low carbon and low water electric power plant operations: implications for upstream water use

    Data.gov (United States)

    U.S. Environmental Protection Agency — The dataset includes all data used in the creation of figures and graphs in the paper: "Scenarios for low carbon and low water electric power plant operations:...

  15. Operational electricity transmission rates

    International Nuclear Information System (INIS)

    Roggen, M.

    1997-01-01

    In a liberalized electricity market both the consumers and the producers of electricity must pay for the use of the power transmission network. Thus, the net manager has unlimited options to realize efficiency improvements. A neutral and transparent management of the power grid is necessary to avoid disturbance of the market. KEMA Consulting translated abstract ideas and strategic advices to operational concepts in its report 'A framework for the determination of tariffs of the transport in the Dutch electricity sector'

  16. Electric-drive tractability indicator integrated in hybrid electric vehicle tachometer

    Science.gov (United States)

    Tamai, Goro; Zhou, Jing; Weslati, Feisel

    2014-09-02

    An indicator, system and method of indicating electric drive usability in a hybrid electric vehicle. A tachometer is used that includes a display having an all-electric drive portion and a hybrid drive portion. The all-electric drive portion and the hybrid drive portion share a first boundary which indicates a minimum electric drive usability and a beginning of hybrid drive operation of the vehicle. The indicated level of electric drive usability is derived from at least one of a percent battery discharge, a percent maximum torque provided by the electric drive, and a percent electric drive to hybrid drive operating cost for the hybrid electric vehicle.

  17. Practical operation strategies for pumped hydroelectric energy storage (PHES) utilising electricity price arbitrage

    International Nuclear Information System (INIS)

    Connolly, D.; Lund, H.; Finn, P.; Mathiesen, B.V.; Leahy, M.

    2011-01-01

    In this paper, three practical operation strategies (24Optimal, 24Prognostic, and 24Hsitrocial) are compared to the optimum profit feasible for a PHES facility with a 360 MW pump, 300 MW turbine, and a 2 GWh storage utilising price arbitrage on 13 electricity spot markets. The results indicate that almost all (∼97%) of the profits can be obtained by a PHES facility when it is optimised using the 24Optimal strategy developed, which optimises the energy storage based on the day-ahead electricity prices. However, to maximise profits with the 24Optimal strategy, the day-ahead electricity prices must be the actual prices which the PHES facility is charged or the PHES operator must have very accurate price predictions. Otherwise, the predicted profit could be significantly reduced and even become a loss. Finally, using the 24Optimal strategy, the PHES profit can surpass the annual investment repayments required. However, over the 5-year period investigated (2005-2009) the annual profit from the PHES facility varied by more than 50% on five out of six electricity markets considered. Considering the 40-year lifetime of PHES, even with low investment costs, a low interest rate, and a suitable electricity market, PHES is a risky investment without a more predictable profit. - Highlights: → Electricity generators typically operate on a market, including energy storage. → This paper assesses how energy storage can maximise its profits on a market. → Four operating strategies are assessed on 13 markets using a case study.→ One operating strategy achieves 97% of the profits feasible.→ However, the profit varies a lot depending on the market and capital costs.

  18. Evaluation of all-electric secondary power for transport aircraft

    Science.gov (United States)

    Murray, W. E.; Feiner, L. J.; Flores, R. R.

    1992-01-01

    This report covers a study by Douglas Aircraft Company (DAC) of electrical power systems for advanced transport aircraft based upon an all-electric design concept. The concept would eliminate distributed hydraulic and pneumatic secondary power systems, and feature an expanded secondary electrical power system redesigned to supply power to the loads customarily supplied by hydraulic or pneumatic power. The initial study was based on an advanced 20-kHz electrical power transmission and distribution system, using a system architecture supplied by NASA-Lewis Research Center for twin-engine aircraft with many advanced power conversion concepts. NASA-LeRC later requested DAC to refocus the study on 400-Hz secondary power distribution. Subsequent work was based on a three-engine MD-11 aircraft, selected by DAC as a baseline system design that would provide data for the comparative cost/benefit analysis. The study concluded that the 20-kHz concept produced many expected benefits, and that the all-electric trijet weight savings on hardware redesign would be 2,304 pounds plus a 2.1-percent fuel reduction and resized for a total weight reduction of 11,000 pounds. Cost reductions for a fleet of 800 aircraft in a 15-year production program were estimated at $76.71 million for RDT&E; $2.74 million per aircrat for production; $9.84 million for nonrecurring expenses; $120,000 per aircraft for product support; and $300,000 per aircraft per year for operating and maintenance costs, giving a present value of $1.914 billion saved or a future value of $10.496 billion saved.

  19. QCD corrections to neutron electric dipole moment from dimension-six four-quark operators

    Energy Technology Data Exchange (ETDEWEB)

    Hisano, Junji, E-mail: hisano@eken.phys.nagoya-u.ac.jp [Department of Physics, Nagoya University, Nagoya 464-8602 (Japan); IPMU, TODIAS, University of Tokyo, Kashiwa 277-8568 (Japan); Tsumura, Koji, E-mail: ko2@eken.phys.nagoya-u.ac.jp [Department of Physics, Nagoya University, Nagoya 464-8602 (Japan); Department of Physics, National Taiwan University, Taipei 10617, Taiwan (China); Yang, Masaki J.S., E-mail: yang@eken.phys.nagoya-u.ac.jp [Department of Physics, Nagoya University, Nagoya 464-8602 (Japan); Department of Physics, University of Tokyo, Tokyo 113-0033 (Japan)

    2012-07-18

    In this Letter, the renormalization-group equations for the (flavor-conserving) CP-violating interaction are derived up to the dimension six, including all the four-quark operators, at one-loop level. We apply them to the models with the neutral scalar boson or the color-octet scalar boson which have CP-violating Yukawa interactions with quarks, and discuss the neutron electric dipole moment in these models.

  20. HEMP emergency planning and operating procedures for electric power systems

    Energy Technology Data Exchange (ETDEWEB)

    Reddoch, T.W.; Markel, L.C. (Electrotek Concepts, Inc., Knoxville, TN (United States))

    1991-01-01

    Investigations of the impact of high-altitude electromagnetic pulse (HEMP) on electric power systems and electrical equipment have revealed that HEMP creates both misoperation and failures. These events result from both the early time E[sub 1] (steep-front pulse) component and the late time E[sub 3] (geomagnetic perturbations) component of HEMP. In this report a HEMP event is viewed in terms of its marginal impact over classical power system disturbances by considering the unique properties and consequences of HEMP. This report focuses on system-wide electrical component failures and their potential consequences from HEMP. In particular, the effectiveness of planning and operating procedures for electric systems is evaluated while under the influence of HEMP. This assessment relies on published data and characterizes utilities using the North American Electric Reliability Council's regions and guidelines to model electric power system planning and operations. Key issues addressed by the report include how electric power systems are affected by HEMP and what actions electric utilities can initiate to reduce the consequences of HEMP. The report also reviews the salient features of earlier HEMP studies and projects, examines technology trends in the electric power industry which are affected by HEMP, characterizes the vulnerability of power systems to HEMP, and explores the capability of electric systems to recover from a HEMP event.

  1. Electromagnetic compatibility and the all-electric airplane

    Science.gov (United States)

    Christman, Al

    1995-01-01

    NASA is studying the feasibility of installing 'all-electric' controls in future commercial aircraft, replacing the current hydraulic and pneumatic systems. Planes utilizing such equipment should weigh less and be cheaper to maintain, but might also be susceptible to interference from undesired external electromagnetic fields. Possible sources of these extraneous signals include radio and television broadcasters, two-way communications stations, and radar installations of all kinds. One way to reduce the hazard would be to use fiber-optic cables to carry signals from the cockpit to the various points of use, a concept known as 'fly-by-light' or FBL. However, electrical circuits (PBW, or 'power-by-wire') would still be required at both ends of the cables to perform control functions, so the possibility of harmful interference would remain. Computer models for two different antennas were created in order to find the magnitude of the electric fields which would be generated in the airspace around them while in the transmit mode. The first antenna was a horizontal 'rhombic' used by the Voice of America (VOA) for long-distance short-wave broadcasting. The second antenna was a multi-element 'log-periodic dipole array' (LPDA) of a type often used for two-way radio communications. For each case, a specified amount of power was applied in the computer model, and the resulting electric field intensity was predicted at a variety of locations surrounding the antenna. This information will then be used to calculate the levels of interference which could occur inside an airplane flying in the vicinity of these radiation emitters.

  2. Creation of operation algorithms for combined operation of anti-lock braking system (ABS) and electric machine included in the combined power plant

    Science.gov (United States)

    Bakhmutov, S. V.; Ivanov, V. G.; Karpukhin, K. E.; Umnitsyn, A. A.

    2018-02-01

    The paper considers the Anti-lock Braking System (ABS) operation algorithm, which enables the implementation of hybrid braking, i.e. the braking process combining friction brake mechanisms and e-machine (electric machine), which operates in the energy recovery mode. The provided materials focus only on the rectilinear motion of the vehicle. That the ABS task consists in the maintenance of the target wheel slip ratio, which depends on the tyre-road adhesion coefficient. The tyre-road adhesion coefficient was defined based on the vehicle deceleration. In the course of calculated studies, the following operation algorithm of hybrid braking was determined. At adhesion coefficient ≤0.1, driving axle braking occurs only due to the e-machine operating in the energy recovery mode. In other cases, depending on adhesion coefficient, the e-machine provides the brake torque, which changes from 35 to 100% of the maximum available brake torque. Virtual tests showed that values of the wheel slip ratio are close to the required ones. Thus, this algorithm makes it possible to implement hybrid braking by means of the two sources creating the brake torque.

  3. An Operational Standpoint in Electrical Engineering

    Directory of Open Access Journals (Sweden)

    Frédéric Rotella

    2013-12-01

    Full Text Available In electrical engineering education exists a major difficulty for first level students, namely the Laplace transform. The question is: does this ubiquitous tool is needed in an electrical engineering course? Our answer is: Obviously, not. Based on an operational standpoint the paper describes some guidelines and results for a primer on handling signals and linear systems without using the Laplace transform. The main advantage is that the operational standpoint leads to simplified proofs for well-known results.

  4. HTS machines as enabling technology for all-electric airborne vehicles

    International Nuclear Information System (INIS)

    Masson, P J; Brown, G V; Soban, D S; Luongo, C A

    2007-01-01

    Environmental protection has now become paramount as evidence mounts to support the thesis of human activity-driven global warming. A global reduction of the emissions of pollutants into the atmosphere is therefore needed and new technologies have to be considered. A large part of the emissions come from transportation vehicles, including cars, trucks and airplanes, due to the nature of their combustion-based propulsion systems. Our team has been working for several years on the development of high power density superconducting motors for aircraft propulsion and fuel cell based power systems for aircraft. This paper investigates the feasibility of all-electric aircraft based on currently available technology. Electric propulsion would require the development of high power density electric propulsion motors, generators, power management and distribution systems. The requirements in terms of weight and volume of these components cannot be achieved with conventional technologies; however, the use of superconductors associated with hydrogen-based power plants makes possible the design of a reasonably light power system and would therefore enable the development of all-electric aero-vehicles. A system sizing has been performed both for actuators and for primary propulsion. Many advantages would come from electrical propulsion such as better controllability of the propulsion, higher efficiency, higher availability and less maintenance needs. Superconducting machines may very well be the enabling technology for all-electric aircraft development

  5. HTS machines as enabling technology for all-electric airborne vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Masson, P J [FAMU-FSU College of Engineering and the Center for Advanced Power Systems, Tallahassee, FL 32310 (United States); Brown, G V [NASA Glenn Research Center, Cleveland, OH (United States); Soban, D S [Aerospace System Design Laboratory/Georgia Tech, Atlanta, GA 32332 (United States); Luongo, C A [FAMU-FSU College of Engineering and the Center for Advanced Power Systems, Tallahassee, FL 32310 (United States)

    2007-08-15

    Environmental protection has now become paramount as evidence mounts to support the thesis of human activity-driven global warming. A global reduction of the emissions of pollutants into the atmosphere is therefore needed and new technologies have to be considered. A large part of the emissions come from transportation vehicles, including cars, trucks and airplanes, due to the nature of their combustion-based propulsion systems. Our team has been working for several years on the development of high power density superconducting motors for aircraft propulsion and fuel cell based power systems for aircraft. This paper investigates the feasibility of all-electric aircraft based on currently available technology. Electric propulsion would require the development of high power density electric propulsion motors, generators, power management and distribution systems. The requirements in terms of weight and volume of these components cannot be achieved with conventional technologies; however, the use of superconductors associated with hydrogen-based power plants makes possible the design of a reasonably light power system and would therefore enable the development of all-electric aero-vehicles. A system sizing has been performed both for actuators and for primary propulsion. Many advantages would come from electrical propulsion such as better controllability of the propulsion, higher efficiency, higher availability and less maintenance needs. Superconducting machines may very well be the enabling technology for all-electric aircraft development.

  6. Electricity Infrastructure Operations Center (EIOC)

    Data.gov (United States)

    Federal Laboratory Consortium — The Electricity Infrastructure Operations Center (EIOC) at PNNL brings together industry-leading software, real-time grid data, and advanced computation into a fully...

  7. Flywheel in an all-electric propulsion system

    Energy Technology Data Exchange (ETDEWEB)

    Lundin, Johan

    2011-07-01

    Energy storage is a crucial condition for both transportation purposes and for the use of electricity. Flywheels can be used as actual energy storage but also as power handling device. Their high power capacity compared to other means of storing electric energy makes them very convenient for smoothing power transients. These occur frequently in vehicles but also in the electric grid. In both these areas there is a lot to gain by reducing the power transients and irregularities. The research conducted at Uppsala Univ. and described in this thesis is focused on an all-electric propulsion system based on an electric flywheel with double stator windings. The flywheel is inserted in between the main energy storage (assumed to be a battery) and the traction motor in an electric vehicle. This system has been evaluated by simulations in a Matlab model, comparing two otherwise identical drivelines, one with and one without a flywheel. The flywheel is shown to have several advantages for an all-electric propulsion system for a vehicle. The maximum power from the battery decreases more than ten times as the flywheel absorbs and supplies all the high power fluxes occurring at acceleration and braking. The battery delivers a low and almost constant power to the flywheel. The amount of batteries needed de- creases whereas the battery lifetime and efficiency increases. Another benefit the flywheel configuration brings is a higher energy efficiency and hence less need for cooling. The model has also been used to evaluate the flywheel functionality for an electric grid application. The power from renewable intermittent energy sources such as wave, wind and current power can be smoothened by the fly- wheel, making these energy sources more efficient and thereby competitive with a remaining high power quality in the electric grid

  8. De-regulated electric power markets and operating nuclear power plants: the case of British energy

    International Nuclear Information System (INIS)

    Hewlett, James G.

    2005-01-01

    One issue addressed in almost all electric power restructuring/de-regulation plans in both the United States (US) and the United Kingdom (UK) was the recovery of operating nuclear power plant's spent fuel disposal costs and the expenditures to decommission the units when they are retired. Prior to restructuring, in theory at least, in both countries, electricity consumers were paying for the back end costs from operating nuclear power plants. Moreover, in virtually all cases in the US, states included special provisions to insure that consumers would continue to do so after power markets were de-regulated. When power markets in the UK were initially restructured/de-regulated and nuclear power privatized, the shareholders of British Energy (BE) were initially responsible for these costs. However, after electricity prices fell and BE collapsed, the British government shifted many of the costs to future taxpayers, as much as a century forward. If this was not done, the book value of BE's equity would have been about -3.5 billion pounds. That is, BE's liabilities would have been about -3.5 billion pounds greater than their assets. It is difficult to see how BE could remain viable under such circumstances

  9. Features of Creation and Operation of Electric and Hybrid Vehicles in Countries with Difficult Climatic Conditions, for Example, in the Russian Federation

    Science.gov (United States)

    Karpukhin, K.; Terenchenko, A.

    2016-11-01

    The trend of increasing fleet of electric or hybrid vehicles and determines the extension of the geographical areas of operation, including the Northern areas with cold winter weather. Practically in all territory of Russia the average winter temperature is negative. With the winter temperatures can be below in Moscow -30°C, in Krasnoyarsk -50°C. Battery system can operate in a wide temperature range, but there are extremes that should be remembered all the time, especially in cold climates like Russia. In the operating instructions of the electric car Tesla Model S indicate that to save the battery don't use at temperatures below -15°C. The paper presents the dependence of the cooling time and heating of the battery cell at different ambient temperatures and provides guidance on allowable cooling time while using and not thermally insulated thermally containers Suggests using the temperature control on the basis of thermoelectric converters Peltier connection from the onboard electrical network of the electric vehicle.

  10. Electric Motors Maintenance Planning From Its Operating Variables

    Science.gov (United States)

    Rodrigues, Francisco; Fonseca, Inácio; Farinha, José Torres; Ferreira, Luís; Galar, Diego

    2017-09-01

    The maintenance planning corresponds to an approach that seeks to maximize the availability of equipment and, consequently, increase the levels of competitiveness of companies by increasing production times. This paper presents a maintenance planning based on operating variables (number of hours worked, duty cycles, number of revolutions) to maximizing the availability of operation of electrical motors. The reading of the operating variables and its sampling is done based on predetermined sampling cycles and subsequently is made the data analysis through time series algorithms aiming to launch work orders before reaching the variables limit values. This approach is supported by tools and technologies such as logical applications that enable a graphical user interface for access to relevant information about their Physical Asset HMI (Human Machine Interface), including the control and supervision by acquisition through SCADA (Supervisory Control And data acquisition) data, also including the communication protocols among different logical applications.

  11. Electric power monthly, September 1990. [Glossary included

    Energy Technology Data Exchange (ETDEWEB)

    1990-12-17

    The purpose of this report is to provide energy decision makers with accurate and timely information that may be used in forming various perspectives on electric issues. The power plants considered include coal, petroleum, natural gas, hydroelectric, and nuclear power plants. Data are presented for power generation, fuel consumption, fuel receipts and cost, sales of electricity, and unusual occurrences at power plants. Data are compared at the national, Census division, and state levels. 4 figs., 52 tabs. (CK)

  12. Electric and Hybrid Vehicle Program, Site Operator Program. Quarterly progress report, January--March 1996

    Energy Technology Data Exchange (ETDEWEB)

    Francfort, J.E. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States); Bassett, R.R. [Sandia National Labs., Albuquerque, NM (United States); Briasco, S. [Los Angeles City Dept. of Water and Power, CA (United States)] [and others

    1996-08-01

    Goals of the site operator program include field evaluation of electric vehicles (EVs) in real-world applications and environments, advancement of electric vehicle technologies, development of infrastructure elements necessary to support significant EV use, and increasing the awareness and acceptance of EVs by the public. The site operator program currently consists of 11 participants under contract and two other organizations with data-sharing agreements with the program. The participants (electric utilities, academic institutions, Federal agencies) are geographically dispersed within US and their vehicles see a broad spectrum of service conditions. Current EV inventories of the site operators exceeds 250 vehicles. Several national organizations have joined DOE to further the introduction and awareness of EVs, including: (1) EVAmerica (a utility program) and DOE conduct performance and evaluation tests to support market development for EVs; (2) DOE, DOT, the Electric Transportation Coalition, and the Electric Vehicle Association of the Americas are conducting a series of workshops to encourage urban groups in Clean Cities (a DOE program) to initiate the policies and infrastructure development necessary to support large-scale demonstrations, and ultimately the mass market use, of EVs. Current focus of the program is collection and dissemination of EV operations and performance data to aid in the evaluation of real- world EV use. This report contains several sections with vehicle evaluation as a focus: EV testing results, energy economics of EVs, and site operators activities.

  13. An all-electric single-molecule motor.

    Science.gov (United States)

    Seldenthuis, Johannes S; Prins, Ferry; Thijssen, Joseph M; van der Zant, Herre S J

    2010-11-23

    Many types of molecular motors have been proposed and synthesized in recent years, displaying different kinds of motion, and fueled by different driving forces such as light, heat, or chemical reactions. We propose a new type of molecular motor based on electric field actuation and electric current detection of the rotational motion of a molecular dipole embedded in a three-terminal single-molecule device. The key aspect of this all-electronic design is the conjugated backbone of the molecule, which simultaneously provides the potential landscape of the rotor orientation and a real-time measure of that orientation through the modulation of the conductivity. Using quantum chemistry calculations, we show that this approach provides full control over the speed and continuity of motion, thereby combining electrical and mechanical control at the molecular level over a wide range of temperatures. Moreover, chemistry can be used to change all key parameters of the device, enabling a variety of new experiments on molecular motors.

  14. New Operation and Maintenance Contract for Electrical Network

    CERN Document Server

    Kowalik, G

    2001-01-01

    The Electrical Exploitation is one of the few remaining operation services at CERN which nearly entirely relies on the CERN staff. Last year CERN policy, in connection with the LHC project needs, have led to the formulation of the strategy of out-sourcing of the Electrical Exploitation activities, market survey and subsequent Invitation to Tender. The following paper presents the approach used in the preparation of the Invitation to Tender and in solving of the out-sourcing issues applied to the operation and maintenance of the CERN electrical network. In particular the problems of the results oriented contract, quality assurance and performance as well requirement of the constantly increasing productivity of the Contractors team are treated. The paper gives also the particularities of the application of the out-sourcing to the electrical operation service as will as techniques used for the estimation of the work load of the activities being outsourced.

  15. ELECTRIC MOTORS MAINTENANCE PLANNING FROM ITS OPERATING VARIABLES

    Directory of Open Access Journals (Sweden)

    Francisco RODRIGUES

    2017-07-01

    Full Text Available The maintenance planning corresponds to an approach that seeks to maximize the availability of equipment and, conse-quently, increase the levels of competitiveness of companies by increasing production times. This paper presents a maintenance planning based on operating variables (number of hours worked, duty cycles, number of revolutions to maximizing the availability of operation of electrical motors. The reading of the operating variables and its sampling is done based on predetermined sampling cycles and subsequently is made the data analysis through time series algo-rithms aiming to launch work orders before reaching the variables limit values. This approach is supported by tools and technologies such as logical applications that enable a graphical user interface for access to relevant information about their Physical Asset HMI (Human Machine Interface, including the control and supervision by acquisition through SCADA (Supervisory Control And data acquisition data, also including the communication protocols among different logical applications.

  16. 49 CFR 236.207 - Electric lock on hand-operated switch; control.

    Science.gov (United States)

    2010-10-01

    ..., AND APPLIANCES Automatic Block Signal Systems Standards § 236.207 Electric lock on hand-operated switch; control. Electric lock on hand-operated switch shall be controlled so that it cannot be unlocked... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock on hand-operated switch; control...

  17. Assessing CO2 Mitigation Options Utilizing Detailed Electricity Characteristics and Including Renewable Generation

    Science.gov (United States)

    Bensaida, K.; Alie, Colin; Elkamel, A.; Almansoori, A.

    2017-08-01

    This paper presents a novel techno-economic optimization model for assessing the effectiveness of CO2 mitigation options for the electricity generation sub-sector that includes renewable energy generation. The optimization problem was formulated as a MINLP model using the GAMS modeling system. The model seeks the minimization of the power generation costs under CO2 emission constraints by dispatching power from low CO2 emission-intensity units. The model considers the detailed operation of the electricity system to effectively assess the performance of GHG mitigation strategies and integrates load balancing, carbon capture and carbon taxes as methods for reducing CO2 emissions. Two case studies are discussed to analyze the benefits and challenges of the CO2 reduction methods in the electricity system. The proposed mitigations options would not only benefit the environment, but they will as well improve the marginal cost of producing energy which represents an advantage for stakeholders.

  18. INTEGRAL INDEX OF OPERATION QUALITY FOR EVALUATION OF IMPACT OF DISTRIBUTIVE GENERATION SOURCES ON ELECTRIC NETWORK MODES

    Directory of Open Access Journals (Sweden)

    Petro D. Lezhniuk

    2017-06-01

    Full Text Available Method of operation quality evaluation of electric network, comprising renewable sources of energy (RSE is considered. Integral index that enables to evaluate the impact of RSE on energy losses and its quality as well as balance reliability in electric network is suggested. Mathematical model is constructed, taking into account the assumption that electric network with RSE may be in various operation modes, characterized by different technical economic indices. To determine the integral index of operation quality of electric network with RSE in all possible states tools of Markov processes theory and criterial method are used.

  19. A Method of Evaluating Operation of Electric Energy Meter

    Science.gov (United States)

    Chen, Xiangqun; Li, Tianyang; Cao, Fei; Chu, Pengfei; Zhao, Xinwang; Huang, Rui; Liu, Liping; Zhang, Chenglin

    2018-05-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  20. Development and Implementation of a Battery-Electric Light-Duty Class 2a Truck including Hybrid Energy Storage

    Science.gov (United States)

    Kollmeyer, Phillip J.

    This dissertation addresses two major related research topics: 1) the design, fabrication, modeling, and experimental testing of a battery-electric light-duty Class 2a truck; and 2) the design and evaluation of a hybrid energy storage system (HESS) for this and other vehicles. The work begins with the determination of the truck's peak power and wheel torque requirements (135kW/4900Nm). An electric traction system is then designed that consists of an interior permanent magnet synchronous machine, two-speed gearbox, three-phase motor drive, and LiFePO4 battery pack. The battery pack capacity is selected to achieve a driving range similar to the 2011 Nissan Leaf electric vehicle (73 miles). Next, the demonstrator electric traction system is built and installed in the vehicle, a Ford F150 pickup truck, and an extensive set of sensors and data acquisition equipment is installed. Detailed loss models of the battery pack, electric traction machine, and motor drive are developed and experimentally verified using the driving data. Many aspects of the truck's performance are investigated, including efficiency differences between the two-gear configuration and the optimal gear selection. The remainder focuses on the application of battery/ultracapacitor hybrid energy storage systems (HESS) to electric vehicles. First, the electric truck is modeled with the addition of an ultracapacitor pack and a dc/dc converter. Rule-based and optimal battery/ultracapacitor power-split control algorithms are then developed, and the performance improvements achieved for both algorithms are evaluated for operation at 25°C. The HESS modeling is then extended to low temperatures, where battery resistance increases substantially. To verify the accuracy of the model-predicted results, a scaled hybrid energy storage system is built and the system is tested for several drive cycles and for two temperatures. The HESS performance is then modeled for three variants of the vehicle design, including the

  1. A Review on the Faults of Electric Machines Used in Electric Ships

    OpenAIRE

    Dionysios V. Spyropoulos; Epaminondas D. Mitronikas

    2013-01-01

    Electric propulsion systems are today widely applied in modern ships, including transport ships and warships. The ship of the future will be fully electric, and not only its propulsion system but also all the other services will depend on electric power. The robust and reliable operation of the ship’s power system is essential. In this work, a review on the mechanical and electrical faults of electric machines that are used in electric ships is presented.

  2. Making the connection: The B.C. Hydro electric system and how it is operated

    International Nuclear Information System (INIS)

    1993-01-01

    British Columbia Hydro supplies electric energy to 93% of the province's population through an integrated electric system. Of the electricity supplied, 95% is generated at 29 hydroelectric plants, with the remainder coming from thermal plants burning fossil fuels. BC Hydro's high voltage transmission and distribution network consists of 17,600 km of lines 60 kV and above and 51,400 km of lines below 60 kV. A description of system operations begins with the principles of hydroelectric generation, with a brief note on thermal generation for peaking or short-term energy production. Non-power operations measures designed to minimize environmental impacts and enhance social benefits are also outlined along with electricity trade with other provinces and the USA. Planning of long- and short-term system operations is also reviewed. An analysis of system components is presented for the Peace, Columbia, Lower Mainland/Coastal/Fraser, and Vancouver Island regions. Finally, information is given on the 29 hydroelectric and 3 thermal plants, including drainage basin, reservoir description and map, inflow, capacity, turbine type, storage, operating constraints, and average energy capability. 51 figs

  3. Scenario-based electric bus operation: A case study of Putrajaya, Malaysia

    OpenAIRE

    Lay Eng Teoh; Hooi Ling Khoo; Siew Yoke Goh; Lai Mun Chong

    2018-01-01

    Globally, transportation sector has emerged as one of the major sources of air pollution. Correspondingly, green mobility (with electric bus) is gaining increasing attention as an essential step to mitigate emission concern. As such, a proper electric bus network design and fleet planning is important especially for bus operator to acquire an adequate number of electric bus, right on time, in order to operate electric bus system viably. Thus, this paper aims to examine the possibility to oper...

  4. Electric Bike Sharing--System Requirements and Operational Concepts

    Energy Technology Data Exchange (ETDEWEB)

    Cherry, Christopher; Worley, Stacy; Jordan, David

    2010-08-01

    Bike sharing is an exciting new model of public-private transportation provision that has quickly emerged in the past five years. Technological advances have overcome hurdles of early systems and cities throughout the globe are adopting this model of transportation service. Electric bikes have simultaneously gained popularity in many regions of the world and some have suggested that shared electric bikes could provide an even higher level of service compared to existing systems. There are several challenges that are unique to shared electric bikes: electric-assisted range, recharging protocol, and bike and battery checkout procedures. This paper outlines system requirements to successfully develop and deploy an electric bike sharing system, focusing on system architecture, operational concepts, and battery management. Although there is little empirical evidence, electric bike sharing could be feasible, depending on demand and battery management, and can potentially improve the utility of existing bike sharing systems. Under most documented bike sharing use scenarios, electric bike battery capacity is insufficient for a full day of operation, depending on recharging protocol. Off-board battery management is a promising solution to address this problem. Off-board battery management can also support solar recharging. Future pilot tests will be important and allow empirical evaluation of electric bikesharing system performance. (auth)

  5. Alternative Fuels Data Center: How Do All-Electric Cars Work?

    Science.gov (United States)

    battery pack to power the electric motor and must be plugged in to a charging station or wall outlet to the typical liquid fuel components, such as a fuel pump, fuel line, or fuel tank. Learn more about electric vehicles. All electric sedan image Key Components of an All-Electric Car Battery (auxiliary): In

  6. Oxide Thin-Film Electronics using All-MXene Electrical Contacts

    KAUST Repository

    Wang, Zhenwei

    2018-02-23

    2D MXenes have shown great promise in electrochemical and electromagnetic shielding applications. However, their potential use in electronic devices is significantly less explored. The unique combination of metallic conductivity and hydrophilic surface suggests that MXenes can also be promising in electronics and sensing applications. Here, it is shown that metallic Ti3C2 MXene with work function of 4.60 eV can make good electrical contact with both zinc oxide (ZnO) and tin monoxide (SnO) semiconductors, with negligible band offsets. Consequently, both n-type ZnO and p-type SnO thin-film transistors (TFTs) have been fabricated entirely using large-area MXene (Ti3C2) electrical contacts, including gate, source, and drain. The n- and p-type TFTs show balanced performance, including field-effect mobilities of 2.61 and 2.01 cm2 V−1 s−1 and switching ratios of 3.6 × 106 and 1.1 × 103, respectively. Further, complementary metal oxide semiconductor (CMOS) inverters are demonstrated. The CMOS inverters show large voltage gain of 80 and excellent noise margin of 3.54 V, which is 70.8% of the ideal value. Moreover, the operation of CMOS inverters is shown to be very stable under a 100 Hz square waveform input. The current results suggest that MXene (Ti3C2) can play an important role as contact material in nanoelectronics.

  7. Analysis of Operational Data: A Proof of Concept for Assessing Electrical Infrastructure Impact

    Science.gov (United States)

    2015-11-01

    Project Number 30, “Analysis of Operational Data for Tactical Situational Understanding” ERDC TR-15-10 ii Abstract Infrastructure variables required...for a community or society to function include basic facilities, services, and installations; and these variables can impact many aspects of daily...life. The structure and functionality of the electrical grid in an operating area can affect multiple operational varia - bles. Other infrastructure

  8. Gas and electricity markets have been open to all professional clients since July 1, 2004? how is it working

    International Nuclear Information System (INIS)

    Carbonnier, R.

    2005-01-01

    The gas and electricity markets have been open to competition for all professional clients since July 1, 2004. In order to achieve proper market operation, measures have been developed by players in the gas and electricity sectors (network managers, suppliers, authorities and clients) within working groups, GTGs and GTEs 2004, under the aegis of the Commission de Regulation de l'Energie (CRE); the measures prepared by those working groups aim at ensuring the simplicity of contractual relationships between users, suppliers and network managers, to implement high performance management tools and to inform market players. Now, the feedback from those measures helps initiate the preparation of the next step, i.e. the opening of energy markets to competition for all clients, including households, on July 1, 2007. On players' request, the CRE is preparing this new term through other working groups, the 2007 Gas Working Group and the 2007 Electricity Working Group, enlarged to user association representatives. The first results are expected in early 2006, for the most structuring aspects, in order to enable players to initiate organisation changes in due time. (author)

  9. Economic Optimization Analysis of Chengdu Electric Community Bus Operation

    Science.gov (United States)

    Yidong, Wang; Yun, Cai; Zhengping, Tan; Xiong, Wan

    2018-03-01

    In recent years, the government has strongly supported and promoted electric vehicles and has given priority to demonstration and popularization in the field of public transport. The economy of public transport operations has drawn increasing attention. In this paper, Chengdu wireless charging pure electric community bus is used as the research object, the battery, air conditioning, driver’s driving behavior and other economic influence factors were analyzed, and optimizing the operation plan through case data analysis, through the reasonable battery matching and mode of operation to help businesses effectively save operating costs and enhance economic efficiency.

  10. Job satisfaction among control room operators of electrical systems.

    Science.gov (United States)

    Macaia, Amanda A Silva; Marqueze, Elaine C; Rotenberg, Lúcia; Fischer, Frida Marina; Moreno, Claudia R C

    2012-01-01

    Shift workers from control centers of electrical systems are a group that has received little attention in Brazil. This study aimed to compare workers' job satisfaction at five control centers of a Brazilian company electrical system, and according to their job titles. The Organization Satisfaction Index (OSI) questionnaire to assess job satisfaction was used. ANOVA was used to compare OSI means, according to job title and control center. The results showed that there is no difference in job satisfaction among job titles, but a significant difference was found according to the control center. A single organizational culture cannot be applied to several branches. It is required to implement actions that would result in job satisfaction improvements among workers of all studied control rooms centers. The high level of education of operators working in all centers might have contributed to the similar values of perceived satisfaction among distinct job titles.

  11. Enhancement of building operations: A successful approach towards national electrical demand management

    International Nuclear Information System (INIS)

    Al-Mulla, A.; Maheshwari, G.P.; Al-Nakib, D.; ElSherbini, A.; Alghimlas, F.; Al-Taqi, H.; Al-Hadban, Y.

    2013-01-01

    Highlights: • Enhanced building operations were applied for eight large government buildings in Kuwait. • The enhanced building operations led to demand savings of 8.90 MW during the national peak hour. • Nationwide guidelines were developed for implementing the enhanced operations in similar government buildings in Kuwait. • The peak electrical demand reduction is likely to be 488 MW by the year 2030. - Abstract: An approach for managing electrical demand through enhanced building operations in hot climates is evaluated and demonstrated in this paper. The approach focuses on implementing enhanced operations in government buildings, since they are easier to implement and administer. These enhanced operations included early reduction of cooling supply before the end of the occupancy period, improved time-of-day control after occupancy period and reduced lighting. A total of eight government buildings with different construction and system characteristics were selected for implementing these enhanced operations. These buildings have a total air-conditioning area of 4.39 × 10 5 m 2 and a combined peak electrical demand of 29.3 MW. The enhanced operations resulted in demand savings of 8.90 MW during the national peak hour. Temperatures build up inside the buildings were monitored and found to be within acceptable ranges. Guidelines for nationwide implementation in similar buildings were developed based on the results of this work. Implementation is estimated to reduce demand by 488 MW by the year 2030, which amounts to capital savings of $585 million. These projected values would be important to adopt energy efficient policies for the country. Additional reductions in energy and fuel consumption are added benefits, which would result in large financial and environmental savings to the country. Moreover, the enhanced building operations would be an important tool to avoid any blackouts by properly reducing the peak electrical demand as well as operating the

  12. Implementing batteries in electrical grids. Possible operating modes for efficient business cases

    Energy Technology Data Exchange (ETDEWEB)

    Kittlaus, Barnabas; Schreider, Achim; Pour, Adel Hassan [Lahmeyer International GmbH, Bad Vilbel (Germany)

    2010-07-01

    For almost two decades, there has been a global trend towards the deregulation and the liberalisation of electricity markets. Previously, national or regional monopolistic utility companies provided services along the entire supply chain of electricity supply: Beginning with the operation of power plants and thus the generation of electricity, continuing through the development and the operation of transmission and local distribution grids, to the connection points. Since all assets belonged to the utility company, they could easily access generation units in order to provide balancing power for the safe and reliable operation of the electricity networks. With the objective of a more efficient and cheaper electricity supply by enabling competition, European Directive 96/92/EC (repealed by 2003/53/EC) enacted so-called ''unbundling'' which meant the break-up of utility companies as full service suppliers into the three service oriented entities; for electricity generation, transmission and supply. Whereas previously a single utility company provided the balancing of the electricity grid with its own assets, as a consequence of the directive, markets developed for the provision of diverse technical services. As long as the utility companies provided these services on their own, technical rather than economic aspects prevailed in their investment decisions. With the establishment of open markets for primary, secondary and tertiary reserve power, commercial interfaces had been established which force the respective specialised market actor to investment decisions driven primarily by economic aspects. At nearly the same time - around two decades ago, the first renewable energy systems (RES) provided electricity to public grids. In the 1990's their share of the overall electricity mix was negligible, but since the beginning of the new millennium more and more countries recognised the ecological and economic advantages of RES and established incentive systems for their

  13. Probability of inadvertent operation of electrical components in harsh environments

    International Nuclear Information System (INIS)

    Knoll, A.

    1989-01-01

    Harsh environment, which means humidity and high temperature, may and will affect unsealed electrical components by causing leakage ground currents in ungrounded direct current systems. The concern in a nuclear power plant is that such harsh environment conditions could cause inadvertent operation of normally deenergized components, which may have a safety-related isolation function. Harsh environment is a common cause failure, and one way to approach the problem is to assume that all the unsealed electrical components will simultaneously and inadvertently energize as a result of the environmental common cause failure. This assumption is unrealistically conservative. Test results indicated that insulating resistences of any terminal block in harsh environments have a random distribution in the range of 1 to 270 kΩ, with a mean value ∼59 kΩ. The objective of this paper is to evaluate a realistic conditional failure probability for inadvertent operation of electrical components in harsh environments. This value will be used thereafter in probabilistic safety evaluations of harsh environment events and will replace both the overconservative common cause probability of 1 and the random failure probability used for mild environments

  14. Control area readiness audit report of the Independent Electricity Market Operator (IMO)

    International Nuclear Information System (INIS)

    Gladish, L.A.; Campoli, G.; Le, Q.; Farrokhpay, S.; Kirby, B.; Penwell, C.; Weaver, S.; Vicini, D.; Wells, M.

    2004-01-01

    The Independent Electricity Market Operator (IMO) is a control area authority that is responsible for the safe and reliable operation of its portion of the bulk electric system in cooperation with neighbouring control areas. This audit by the North American Electric Reliability Council (NERC) reviewed the readiness of Ontario's IMO to meets its responsibilities as a control area operator. NERC recommended specific actions to correct the deficiencies that resulted in the blackout in southeastern Ontario and northeastern United States on August 14, 2003. Initiatives to strengthen compliance with existing standards were also suggested along with longer-term technical initiatives to prevent or mitigate the impacts of cascading blackouts in the future. The audit process included: a self-assessment questionnaire to the control area being audited; a questionnaire to neighbouring control areas; a questionnaire to the reliability coordinator and an on-site audit by a selected audit team. The following issues were reviewed: criteria and compliance, authority, responsibilities in the planning time frame, real time monitoring, system restoration, delegation of reliability coordinator functions, outage coordination, transmission and generation relaying, energy emergency plan, operating policy, line clearances, and nuclear power plant requirements. It was concluded that the IMO has the necessary plans, procedures, processes, tools and trained personnel to respond to emergency events. The audit did not find any major operational problems, but offered a few recommendations for improvement. tabs

  15. Systems Analysis Developed for All-Electric Aircraft Propulsion

    Science.gov (United States)

    Kohout, Lisa L.

    2004-01-01

    There is a growing interest in the use of fuel cells as a power source for all-electric aircraft propulsion as a means to substantially reduce or eliminate environmentally harmful emissions. Among the technologies under consideration for these concepts are advanced proton exchange membrane (PEM) and solid oxide fuel cells (SOFCs), alternative fuels and fuel processing, and fuel storage. A multidisciplinary effort is underway at the NASA Glenn Research Center to develop and evaluate concepts for revolutionary, nontraditional fuel cell power and propulsion systems for aircraft applications. As part of this effort, system studies are being conducted to identify concepts with high payoff potential and associated technology areas for further development. To support this effort, a suite of component models was developed to estimate the mass, volume, and performance for a given system architecture. These models include a hydrogen-air PEM fuel cell; an SOFC; balance-of-plant components (compressor, humidifier, separator, and heat exchangers); compressed gas, cryogenic, and liquid fuel storage tanks; and gas turbine/generator models for hybrid system applications. First-order feasibility studies were completed for an all-electric personal air vehicle utilizing a fuel-cell-powered propulsion system. A representative aircraft with an internal combustion engine was chosen as a baseline to provide key parameters to the study, including engine power and subsystem mass, fuel storage volume and mass, and aircraft range. The engine, fuel tank, and associated ancillaries were then replaced with a fuel cell subsystem. Various configurations were considered including a PEM fuel cell with liquid hydrogen storage, a direct methanol PEM fuel cell, and a direct internal reforming SOFC/turbine hybrid system using liquid methane fuel. Each configuration was compared with the baseline case on a mass and range basis.

  16. Fort Calhoun Station, Unit 1. Annual operation report: January-December 1977 (including environmental report)

    International Nuclear Information System (INIS)

    1978-02-01

    Net electrical energy generated in 1977 was 2,922,683.7 MWH with the generator on line 6,959.8 hours. Information is presented concerning operations, power generation, shutdowns, maintenance, changes, tests, experiments, occupational personnel radiation exposures, and primary coolant chemistry. Data on radioactive effluent releases, meteorology, environmental monitoring, and potential radiation doses to individuals for July 7, 1977 to December 31, 1977 are also included

  17. State Regulatory responses to acid rain: Implications for electric utility operations

    International Nuclear Information System (INIS)

    Nagelhout, M.

    1990-01-01

    This article discusses the state regulatory responses to acid rain legislation and how this will affect electric utility operations. Topics discusses include planning and fuel procurement practices, least-cost planning, long-term supply contracts, fuel mix, cogeneration and small power production, qualifying facility contracts, avoided costs, environmental impact, lobbying expense, bill inserts, and forecasting models

  18. Thermal burn and electrical injuries among electric utility workers, 1995-2004.

    Science.gov (United States)

    Fordyce, Tiffani A; Kelsh, Michael; Lu, Elizabeth T; Sahl, Jack D; Yager, Janice W

    2007-03-01

    This study describes the occurrence of work-related injuries from thermal-, electrical- and chemical-burns among electric utility workers. We describe injury trends by occupation, body part injured, age, sex, and circumstances surrounding the injury. This analysis includes all thermal, electric, and chemical injuries included in the Electric Power Research Institute (EPRI) Occupational Health and Safety Database (OHSD). There were a total of 872 thermal burn and electric shock injuries representing 3.7% of all injuries, but accounting for nearly 13% of all medical claim costs, second only to the medical costs associated with sprain- and strain-related injuries (38% of all injuries). The majority of burns involved less than 1 day off of work. The head, hands, and other upper extremities were the body parts most frequently injured by burns or electric shocks. For this industry, electric-related burns accounted for the largest percentage of burn injuries, 399 injuries (45.8%), followed by thermal/heat burns, 345 injuries (39.6%), and chemical burns, 51 injuries (5.8%). These injuries also represented a disproportionate number of fatalities; of the 24 deaths recorded in the database, contact with electric current or with temperature extremes was the source of seven of the fatalities. High-risk occupations included welders, line workers, electricians, meter readers, mechanics, maintenance workers, and plant and equipment operators.

  19. Electric drive systems including smoothing capacitor cooling devices and systems

    Energy Technology Data Exchange (ETDEWEB)

    Dede, Ercan Mehmet; Zhou, Feng

    2017-02-28

    An electric drive system includes a smoothing capacitor including at least one terminal, a bus bar electrically coupled to the at least one terminal, a thermoelectric device including a first side and a second side positioned opposite the first side, where the first side is thermally coupled to at least one of the at least one terminal and the bus bar, and a cooling element thermally coupled to the second side of the thermoelectric device, where the cooling element dissipates heat from the thermoelectric device.

  20. Electric Vehicles in Logistics and Transportation: A Survey on Emerging Environmental, Strategic, and Operational Challenges

    OpenAIRE

    Juan, Angel Alejandro; Mendez, Carlos Alberto; Faulin, Javier; de Armas, Jesica; Grasman, Scott

    2017-01-01

    Current logistics and transportation (L&T) systems include heterogeneous fleets consisting of common internal combustion engine vehicles as well as other types of vehicles using ?green? technologies, e.g., plug-in hybrid electric vehicles and electric vehicles (EVs). However, the incorporation of EVs in L&T activities also raise some additional challenges from the strategic, planning, and operational perspectives. For instance, smart cities are required to provide recharge stations for electr...

  1. Nuclear electric power safety, operation, and control aspects

    CERN Document Server

    Knowles, J Brian

    2013-01-01

    Assesses the engineering of renewable sources for commercial power generation and discusses the safety, operation, and control aspects of nuclear electric power From an expert who advised the European Commission and UK government in the aftermath of Three Mile Island and Chernobyl comes a book that contains experienced engineering assessments of the options for replacing the existing, aged, fossil-fired power stations with renewable, gas-fired, or nuclear plants. From geothermal, solar, and wind to tidal and hydro generation, Nuclear Electric Power: Safety, Operation, and Control Aspects ass

  2. A practical algorithm for optimal operation management of distribution network including fuel cell power plants

    Energy Technology Data Exchange (ETDEWEB)

    Niknam, Taher; Meymand, Hamed Zeinoddini; Nayeripour, Majid [Electrical and Electronic Engineering Department, Shiraz University of Technology, Shiraz (Iran)

    2010-08-15

    Fuel cell power plants (FCPPs) have been taken into a great deal of consideration in recent years. The continuing growth of the power demand together with environmental constraints is increasing interest to use FCPPs in power system. Since FCPPs are usually connected to distribution network, the effect of FCPPs on distribution network is more than other sections of power system. One of the most important issues in distribution networks is optimal operation management (OOM) which can be affected by FCPPs. This paper proposes a new approach for optimal operation management of distribution networks including FCCPs. In the article, we consider the total electrical energy losses, the total electrical energy cost and the total emission as the objective functions which should be minimized. Whereas the optimal operation in distribution networks has a nonlinear mixed integer optimization problem, the optimal solution could be obtained through an evolutionary method. We use a new evolutionary algorithm based on Fuzzy Adaptive Particle Swarm Optimization (FAPSO) to solve the optimal operation problem and compare this method with Genetic Algorithm (GA), Particle Swarm Optimization (PSO), Differential Evolution (DE), Ant Colony Optimization (ACO) and Tabu Search (TS) over two distribution test feeders. (author)

  3. Operating experience and aging-seismic assessment of electric motors

    International Nuclear Information System (INIS)

    Subudhi, M.; Burns, E.L.; Taylor, J.H.

    1985-06-01

    Objectives of this program are to identify concerns related to the aging and service wear of equipment operating in nuclear power plants, to assess their possible impact on plant safety, to identify effective inspection surveillance and monitoring methods and to recommend suitable maintenance practices for mitigating aging related concerns and diminish the rate of degradation due to aging and service wear. Motor design and materials of construction are reviewed to identify age-sensitive components. Operational and accidental stressors are determined, and their effect on promoting aging degradation is assessed. Failure modes, mechanisms, and causes have been reviewed from operating experiences and existing data banks. The study has also included consideration for the seismic correlation of age-degraded motor components. The aforementioned reviews and assessments were assimilated to characterize the dielectric, rotational, and mechanical hazards on motor performance and operational readiness. The functional indicators which can be monitored to assess motor component deterioration due to aging or other accidental stressors are identified. Conforming with the NPAR strategy as outlined in the program plan, the study also includes a preliminary discussion of current standards and guides, maintenance programs, and research activities pertaining to nuclear power plant safety-related electric motors

  4. Optimal Operation of Electric Vehicles in Competitive Electricity Markets and Its Impact on Distribution Power Systems

    DEFF Research Database (Denmark)

    Hu, Weihao; Chen, Zhe; Bak-Jensen, Birgitte

    2011-01-01

    represent the future of electricity markets in some ways, is chosen as the studied power system in this paper. The impact of the optimal operation strategy for electric vehicles together with the optimal load response to spot market price on the distribution power system with high wind power penetrations...... are also discussed in the paper. Simulation results show that the proposed optimal operation strategy is an effective measure to achieve minimum energy costs of the PEV. The optimal operation strategy of the PEV and the optimal load response may have significant effects on the distribution power system......Since the hourly spot market price is available one day ahead in Denmark, the electricity price could be transferred to the consumers and they may make some optimal charge and discharge schedules for their electric vehicles in order to minimize their energy costs. This paper presents an optimal...

  5. Evaluation of energy requirements for all-electric range of plug-in hybrid electric two-wheeler

    International Nuclear Information System (INIS)

    Amjad, Shaik; Rudramoorthy, R.; Neelakrishnan, S.; Sri Raja Varman, K.; Arjunan, T.V.

    2011-01-01

    Recently plug-in hybrid electric vehicles (PHEVs) are emerging as one of the promising alternative to improve the sustainability of transportation energy and air quality especially in urban areas. The all-electric range in PHEV design plays a significant role in sizing of battery pack and cost. This paper presents the evaluation of battery energy and power requirements for a plug-in hybrid electric two-wheeler for different all-electric ranges. An analytical vehicle model and MATLAB simulation analysis has been discussed. The MATLAB simulation results estimate the impact of driving cycle and all-electric range on energy capacity, additional mass and initial cost of lead-acid, nickel-metal hydride and lithium-ion batteries. This paper also focuses on influence of cycle life on annual cost of battery pack and recommended suitable battery pack for implementing in plug-in hybrid electric two-wheelers. -- Research highlights: → Evaluates the battery energy and power requirements for a plug-in hybrid electric two-wheeler. → Simulation results reveal that the IDC demand more energy and cost of battery compared to ECE R40. → If cycle life is considered, the annual cost of Ni-MH battery pack is lower than lead-acid and Li-ion.

  6. Hierarchical control of a photovoltaic/battery based DC microgrid including electric vehicle wireless charging station

    DEFF Research Database (Denmark)

    Xiao, Zhao xia; Fan, Haodong; Guerrero, Josep M.

    2017-01-01

    In this paper, the hierarchical control strategy of a photovoltaic/battery based dc microgrid is presented for electric vehicle (EV) wireless charging. Considering irradiance variations, battery charging/discharging requirements, wireless power transmission characteristics, and onboard battery...... coils, receiving coils and compensation capacitors, the wireless power transmission system is designed to be resonant when it is operating at the rated power, with the aim to achieve the optimum transmission system efficiency. Simulation and experimental results of the hierarchical control...... charging power change and other factors, the possible operation states are obtained. A hierarchical control strategy is established, which includes central and local controllers. The central controller is responsible for the selection and transfer of operation states and the management of the local...

  7. HEMP emergency planning and operating procedures for electric power systems. Power Systems Technology Program

    Energy Technology Data Exchange (ETDEWEB)

    Reddoch, T.W.; Markel, L.C. [Electrotek Concepts, Inc., Knoxville, TN (United States)

    1991-12-31

    Investigations of the impact of high-altitude electromagnetic pulse (HEMP) on electric power systems and electrical equipment have revealed that HEMP creates both misoperation and failures. These events result from both the early time E{sub 1} (steep-front pulse) component and the late time E{sub 3} (geomagnetic perturbations) component of HEMP. In this report a HEMP event is viewed in terms of its marginal impact over classical power system disturbances by considering the unique properties and consequences of HEMP. This report focuses on system-wide electrical component failures and their potential consequences from HEMP. In particular, the effectiveness of planning and operating procedures for electric systems is evaluated while under the influence of HEMP. This assessment relies on published data and characterizes utilities using the North American Electric Reliability Council`s regions and guidelines to model electric power system planning and operations. Key issues addressed by the report include how electric power systems are affected by HEMP and what actions electric utilities can initiate to reduce the consequences of HEMP. The report also reviews the salient features of earlier HEMP studies and projects, examines technology trends in the electric power industry which are affected by HEMP, characterizes the vulnerability of power systems to HEMP, and explores the capability of electric systems to recover from a HEMP event.

  8. Electrical machines and assemblies including a yokeless stator with modular lamination stacks

    Science.gov (United States)

    Qu, Ronghai; Jansen, Patrick Lee; Bagepalli, Bharat Sampathkumar; Carl, Jr., Ralph James; Gadre, Aniruddha Dattatraya; Lopez, Fulton Jose

    2010-04-06

    An electrical machine includes a rotor with an inner rotor portion and an outer rotor portion, and a double-sided yokeless stator. The yokeless stator includes modular lamination stacks and is configured for radial magnetic flux flow. The double-sided yokeless stator is concentrically disposed between the inner rotor portion and the outer rotor portion of the electrical machine. Examples of particularly useful embodiments for the electrical machine include wind turbine generators, ship propulsion motors, switch reluctance machines and double-sided synchronous machines.

  9. Equivalent Electrical Circuits of Thermoelectric Generators under Different Operating Conditions

    Directory of Open Access Journals (Sweden)

    Saima Siouane

    2017-03-01

    Full Text Available Energy harvesting has become a promising and alternative solution to conventional energy generation patterns to overcome the problem of supplying autonomous electrical systems. More particularly, thermal energy harvesting technologies have drawn a major interest in both research and industry. Thermoelectric Generators (TEGs can be used in two different operating conditions, under constant temperature gradient or constant heat flow. The commonly used TEG electrical model, based on a voltage source in series with an electrical resistance, shows its limitations especially under constant heat flow conditions. Here, the analytical electrical modeling, taking into consideration the internal and contact thermal resistances of a TEG under constant temperature gradient and constant heat flow conditions, is first given. To give further insight into the electrical behavior of a TEG module in different operating conditions, we propose a new and original way of emulating the above analytical expressions with usual electronics components (voltage source, resistors, diode, whose values are determined with the TEG’s parameters. Note that such a TEG emulation is particularly suited when designing the electronic circuitry commonly associated to the TEG, to realize both Maximum Power Point Tracking and output voltage regulation. First, the proposed equivalent electrical circuits are validated through simulation with a SPICE environment in static operating conditions using only one value of either temperature gradient or heat flow. Then, they are also analyzed in dynamic operating conditions where both temperature gradient and heat flow are considered as time-varying functions.

  10. The neutron electric dipole moment and the Weinberg's operator

    International Nuclear Information System (INIS)

    Li Chongsheng; Hu Bingquan

    1992-01-01

    After a summary of the predictions for the neutron electric dipole moment in a number of models of CP violation, the authors review mainly the recent developments associated with Weimberg's purely gluonic CP violation operator. Its implications on the neutron electric dipole moment in various models of CP violation are discussed. Inspired by Weimberg's work, several new mechanisms of generating large electric dipole moments of charged leptons and large electric and chromo-electric dipole moments of light quarks are recently proposed. Brief discussions on these new developments are also given

  11. Practical operation strategies for pumped hydroelectric energy storage (PHES) utilising electricity price arbitrage

    DEFF Research Database (Denmark)

    Connolly, David; Lund, Henrik; Finn, P.

    2011-01-01

    In this paper, three practical operation strategies (24Optimal, 24Prognostic, and 24Hsitrocial) are compared to the optimum profit feasible for a PHES facility with a 360 MW pump, 300 MW turbine, and a 2 GWh storage utilising price arbitrage on 13 electricity spot markets. The results indicate...... that almost all (not, vert, similar97%) of the profits can be obtained by a PHES facility when it is optimised using the 24Optimal strategy developed, which optimises the energy storage based on the day-ahead electricity prices. However, to maximise profits with the 24Optimal strategy, the day......-ahead electricity prices must be the actual prices which the PHES facility is charged or the PHES operator must have very accurate price predictions. Otherwise, the predicted profit could be significantly reduced and even become a loss. Finally, using the 24Optimal strategy, the PHES profit can surpass the annual...

  12. Plasma waves and electrical discharges stimulated by beam operations on a high altitude satellite

    International Nuclear Information System (INIS)

    Koons, H.C.; Cohen, H.A.

    1982-01-01

    A satellite experiment was conducted to measure the characteristics of the spacecraft charging process near synchronous orbit. The payload included a particle beam system (both an electron gun and an ion gun) and a charging electrical effects analyzer consisting of a pulse shape analyzer, a VLF analyzer, and an RF analyzer. The characteristics of plasma waves and electrical discharges measured by these instruments during electron and ion beam operations are discussed

  13. Working group on unbundling of electricity trade operations 2. A group report

    International Nuclear Information System (INIS)

    2000-09-01

    The current unbundling of operations in accounts has proved inadequate. No formula or model that could be made binding by provisions have been defined for unbundled accounts. In addition, unbundling can draw a distinct line between commercial activities and network operations, which have assumed various authoritative functions. Against this background, the need for clearer unbundling has become more marked. The working group suggests that the current provisions on unbundling of trade operations should be tightened and that the unbundling should be made clearer especially in terms of allocation of joint costs. For this, the necessary preparations by the authorities should be initiated urgently. At the same time, the working group proposes that network operations should be unbundled from other operations by incorporation or by unbundling them into a separate public utility. The smallest electric utilities should be exempted from the obligation of incorporating network operations. According to the working group, the lower limit could be fixed e.g. at 70 GWh a year. The working group also suggests that the licensees must own the electricity networks they operate. The licensees could not rent their networks from the mother company nor lease them from a financing company. The model proposed by the working group would redress the major problems connected with the supervision of the electricity market. The monopoly, i.e. the electricity network operations, under the supervision of the Electricity Market Authority could thus be unbundled. This would improve the functioning of the market and facilitate the supervision. However, the model would not abolish the tax concession of municipal public utilities in competitive trade operations, production and sale of electricity. The tax concession may affect the competitive situation on the electricity market. (orig.)

  14. Results from the Operational Testing of the General Electric Smart Grid Capable Electric Vehicle Supply Equipment (EVSE)

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, Richard Barney [Idaho National Lab. (INL), Idaho Falls, ID (United States); Scoffield, Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bennett, Brion [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-12-01

    The Idaho National Laboratory conducted testing and analysis of the General Electric (GE) smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from GE for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the GE smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

  15. RTE - Electricity transport network operator. Energy is our future: let's save it

    International Nuclear Information System (INIS)

    2014-01-01

    Managing and developing the French electricity transport network is essential to provide quality electricity on a continuous basis to all consumers. Since it was founded in 2000, and since it was made into a public service company (2005), RTE has proven its ability to fulfil its public interest mission in complete security. In an open European electricity market, RTE is recognised for offering all of its customers fair access to its network, which is the first condition for healthy competition. Based on this and thanks to its investments and operating quality, RTE is constantly improving its performances to meet its customers', public authorities' and the Energy Regulation Committee's requirements. This public service action is focused on four strategic priorities: performance of industrial facilities; a human and managerial policy focused on skills and efficiency; sustainable development; professionalism and innovation. This brochure presents RTE's missions, company overview and European cooperation

  16. Independent Electricity Market Operator integration management participant technical reference manual

    International Nuclear Information System (INIS)

    1999-01-01

    The document provides potential participants with the essential technical information to permit them to participate in the IMO-administered markets, and is not intended to be a complete technical reference manual for all issues within the realm of electricity production, distribution, or consumption. Written for the participants, it provides only that information which is relevant to the participant for interfacing with the IMO and participating in the market. Written as a generic guide, all the information contained within it may not be relevant to all the participants. The document's intent is to provide participants with a description of the various facilities and interfaces required by market participants to take part in the IMO-administered markets. The document supplements the market rules and provides installation, set-up, and configuration information for the various tools and facilities that will be required for market participation as a supplier, carrier/delivery (transmitter/distributor), generator, or consumer in the market. Aspects considered include: participant workstation specifications, dispatch workstation specification, message exchange, remote terminal unit specification, AGC operational RTU specification, real time network connection specification, telephone connection specification, revenue administration specification, funds administration specification, data catalogues, market information, power grid connection requirements, and appendices

  17. Electrical lysis: dynamics revisited and advances in On-chip operation.

    Science.gov (United States)

    Morshed, Bashir; Shams, Maitham; Mussivand, Tofy

    2013-01-01

    Electrical lysis (EL) is the process of breaking the cell membrane to expose the internal contents under an applied high electric field. Lysis is an important phenomenon for cellular analysis, medical treatment, and biofouling control. This paper aims to review, summarize, and analyze recent advancements on EL. Major databases including PubMed, Ei Engineering Village, IEEE Xplore, and Scholars Portal were searched using relevant keywords. More than 50 articles published in English since 1997 are cited in this article. EL has several key advantages compared to other lysis techniques such as chemical, mechanical, sonication, or laser, including rapid speed of operation, ability to control, miniaturization, low cost, and low power requirement. A variety of cell types have been investigated for including protoplasts, E. coli, yeasts, blood cells, and cancer cells. EL has been developed and applied for decontamination, cytology, genetics, single-cell analysis, cancer treatment, and other applications. On-chip EL is a promising technology for multiplexed automated implementation of cell-sample preparation and processing with micro- or nanoliter reagents.

  18. Sprag solenoid brake. [development and operations of electrically controlled brake

    Science.gov (United States)

    Dane, D. H. (Inventor)

    1974-01-01

    The development and characteristics of an electrically operated brake are discussed. The action of the brake depends on energizing a solenoid which causes internally spaced sprockets to contact the inner surface of the housing. A spring forces the control member to move to the braking position when the electrical function is interrupted. A diagram of the device is provided and detailed operating principles are explained.

  19. Electric fuses operation, a review: 2. Arcing period

    International Nuclear Information System (INIS)

    Bussière, W

    2012-01-01

    In the electric fuse operation the arcing period follows immediately the pre-arcing period depicted in Part 1 (Part 1. Pre-arcing period). The transition between these two operation steps is not fully understood at this time. To simplify the beginning of the arcing period can be identified with the electric arc ignition i.e. with the electrodes voltage drop. The consecutive plasma is of metallic type at the beginning of the arcing period and of metallic plus silica type with varying mixture up to the end of the arcing period. The energy brought by the fault current is withdrawn by means of the interaction between the electric arc and the arc quenching material (usually silica sand) whose morphometric properties influence the properties of the plasma column: composition, thermodynamic properties and transport coefficients of the plasma column depend on the porosity (and other morphometric properties) of the filler. The fuse element erosion also known as burn-back is responsible for the lengthening of the plasma column and the variations of the electric field. The whole of these processes is depicted by means of experimental results or modellings when possible.

  20. New information technologies in operative control of modes in regional electrical power systems

    OpenAIRE

    ANDREY D. TEVJASHEV; TATJANA B. TIMOFEEVA

    2003-01-01

    The problem of development of software for management of modes in electrical power systems in connection with casual character of a load in network is considered. The stochastic mathematical model of a system for operating control of modes in regional electrical power systems is offered. The methods for problem solving of operating control and operating planning of operational modes in regional electrical power systems are developed. The application of the developed models and methods will al...

  1. Application of Network-Constrained Transactive Control to Electric Vehicle Charging for Secure Grid Operation

    DEFF Research Database (Denmark)

    Hu, Junjie; Yang, Guangya; Bindner, Henrik W.

    2016-01-01

    including power transformer congestion and voltage violations. In this method, a price coordinator is introduced to facilitate the interaction between the distribution system operator (DSO) and aggregators in the smart grid. Electric vehicles are used to illustrate the proposed network...

  2. Reducing operating costs: A collaborative approach between industry and electric utilities

    International Nuclear Information System (INIS)

    Tyers, B.; Sibbald, L.

    1993-01-01

    The unit cost of electricity to industrial consumers is expected to increase at a rate of 5% annually in the 1990s. The partnership that has been created between Amoco Canada Petroleum Company and TransAlta Utilities to control the cost of electricity is described. To allow the company to receive lower rates for interruptible power, a number of measures have been taken. The Amoco Whitecourt plant has standby generators in reserve that can be used when utility power is not available. A Pembina compressor can be turned off for up to 12 hours, at 30 minutes notice, without affecting field pressure. At the East Crossfield plant sales gas can be compressed using electricity or a gas-driven engine. Spot market energy is used in a number of plants allowing electric drive alternatives to plant operators and offering short term energy markets. TransAlta invests in electrical equipment such as switchgear as well as transmission lines and transformers. New rate alternatives offered by TransAlta Utilities include review of the need for a demand ratchet, additional time of use rates, unbundling of rates allowing power purchase from alternative sources, rates that follow product costs, reduced rates for conversion of gas to electric drives certain circumstances, energy audits, and power factor credits. 5 figs

  3. Requirements for a Hydrogen Powered All-Electric Manned Helicopter

    Science.gov (United States)

    Datta, Anubhav

    2012-01-01

    The objective of this paper is to set propulsion system targets for an all-electric manned helicopter of ultra-light utility class to achieve performance comparable to combustion engines. The approach is to begin with a current two-seat helicopter (Robinson R 22 Beta II-like), design an all-electric power plant as replacement for its existing piston engine, and study performance of the new all-electric aircraft. The new power plant consists of high-pressure Proton Exchange Membrane fuel cells, hydrogen stored in 700 bar type-4 tanks, lithium-ion batteries, and an AC synchronous permanent magnet motor. The aircraft and the transmission are assumed to remain the same. The paper surveys the state of the art in each of these areas, synthesizes a power plant using best available technologies in each, examines the performance achievable by such a power plant, identifies key barriers, and sets future technology targets to achieve performance at par with current internal combustion engines.

  4. The spanish electric system operation. The contribution of nuclear generation

    International Nuclear Information System (INIS)

    Duvison, M. R.; Torre, M. de la

    2009-01-01

    Operation of an electric system encloses the collection of activities which extend from affective generation dispatch to issuing instruction for network manoeuvring along with international exchange scheduling. Based on the market mechanisms that apply to energy transactions, these tasks guarantee the security of supply end consumers, which is the final goal of the System Operators actions. In Spain this function is executed by Red Electrica de Espana (REE) since 1985, after being constituted as the first Transmission and System Operator (TSO) in the world. Additionally the variations to Law 54/1997 introduced by law 17/2007 also assign REE the function of sole transmission owner in the Spanish electric system. In order to achieve the aforementioned goal, nuclear energy plays in Spain a fundamental role in electric generation thanks to its high availability rate, the predictability of its fuel recharges, its high operational reliability, its geographical location, the stability of its costs and the security of supply given by the possibility of on-site fuel storage in the power plant. (Author)

  5. Liberalization of power generation sector in the Croatian electricity market

    International Nuclear Information System (INIS)

    Viskovic, Alfredo

    2005-01-01

    The electricity market liberalization and the restructuring of power utilities eventually leads to the establishment of a single electricity market in Europe, which is especially important for efficiency gains in electricity generation coupled with increased security of supply, economic competitiveness and fulfillment of environmental requirements. The European electricity market Directives as well as the Energy Community Treaty for South East Europe (legislative Menu) have remarkable impact on the restructuring of the Croatian power sector and the development of electricity generation. The Croatian model of restructuring includes legal un bundling (in the ownership of one holding company - Hrvatska Elektroprivreda (HEP)). The operation of HEP Group and its subsidiaries in the conditions of partially opened electricity market in an important element that shapes the interactions of competitive activities and regulated activities in the environment influenced by exogenous factors a thirteen percent electricity are controlled by the Energy Market Operator (MO), the Transmission System Operator (TSO) and the Energy Regulatory Agency (CERA). The introduction of eligible procedures and newly created operative procedures for power system operation, are creating completely new conditions for competition in the power generation sector, where almost all power plants are owned by HEP. New generating capacities in Croatia can be built through tendering and licensing procedures carried out by the Regulator. Electricity prices are still regulated by the Government (below the cost reflective level), there is a small share of industrial consumers and the annual electricity production is 12 TWh, with relatively large share of hydro plants. All these have implications on the development of the power generation sector in Croatia as well as on electricity market operation. The subject matter of this paper is an impact of power system restructuring and electricity market opening on the

  6. Operating experience relating to on-site electric power sources. Proceedings of a Specialist Meeting

    International Nuclear Information System (INIS)

    1986-02-01

    The reliability of on-site electric power sources of nuclear power plants usually consisting of diesel generators, gas turbine generators and DC power sources, has been a matter of concern during reactor operations. The frequent recurrence and the important consequences of failures relating to on-site electric power sources have led to a general consensus that they form one of the most significant features influencing the total performance of the safety Systems. This has also been confirmed by surveys performed on the incidents reported through the NEA Incident Reporting System (IRS). Accordingly, a recommendation to organise a Specialist Meeting on the subject was made at the third annual meeting of CSNI Principal Working Group No. 1 (Operating Experience and Human Factors). At the 12. meeting of the CSNI held in November 1984. the Committee endorsed the proposal and accepted an offer by the United Kingdom to host and organise the Specialist Meeting. The Specialist Meeting, sponsored by the CSNI, was held in London, United Kingdom from 16 to 18 October 1985. It was hosted by H.M. Nuclear Installations Inspectorate of the Health and Safety Executive. The purpose of the meeting was to promote the exchange of Information on operating experience relating to on-site electric power sources and to look for measures to further improve their reliability In the areas of design, operation and licensing. The meeting was organised by a Programme Group which included nominated members of CSNI PWG No. 1. the Programme Group met in May and June 1985 in Paris to agree on the programme and practical arrangements for the meeting. As a result of the review of the abstracts which had been contributed in response to the Call for Papers, 28 papers were accepted for presentation during the meeting. Approximately 60 delegates from 13 Member countries, and the NEA Secretariat, attended the meeting. Session summaries prepared by the respective session chairmen are Included prior to the

  7. Operating experience relating to on-site electric power sources. Proceedings of a Specialist Meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-02-15

    The reliability of on-site electric power sources of nuclear power plants usually consisting of diesel generators, gas turbine generators and DC power sources, has been a matter of concern during reactor operations. The frequent recurrence and the important consequences of failures relating to on-site electric power sources have led to a general consensus that they form one of the most significant features influencing the total performance of the safety Systems. This has also been confirmed by surveys performed on the incidents reported through the NEA Incident Reporting System (IRS). Accordingly, a recommendation to organise a Specialist Meeting on the subject was made at the third annual meeting of CSNI Principal Working Group No. 1 (Operating Experience and Human Factors). At the 12. meeting of the CSNI held in November 1984. the Committee endorsed the proposal and accepted an offer by the United Kingdom to host and organise the Specialist Meeting. The Specialist Meeting, sponsored by the CSNI, was held in London, United Kingdom from 16 to 18 October 1985. It was hosted by H.M. Nuclear Installations Inspectorate of the Health and Safety Executive. The purpose of the meeting was to promote the exchange of Information on operating experience relating to on-site electric power sources and to look for measures to further improve their reliability In the areas of design, operation and licensing. The meeting was organised by a Programme Group which included nominated members of CSNI PWG No. 1. the Programme Group met in May and June 1985 in Paris to agree on the programme and practical arrangements for the meeting. As a result of the review of the abstracts which had been contributed in response to the Call for Papers, 28 papers were accepted for presentation during the meeting. Approximately 60 delegates from 13 Member countries, and the NEA Secretariat, attended the meeting. Session summaries prepared by the respective session chairmen are Included prior to the

  8. 29 CFR 780.616 - Operations included in raising livestock.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Operations included in raising livestock. 780.616 Section... Employment in Agriculture and Livestock Auction Operations Under the Section 13(b)(13) Exemption Requirements for Exemption § 780.616 Operations included in raising livestock. Raising livestock includes such...

  9. Advanced Launch System (ALS): Electrical actuation and power systems improve operability and cost picture

    Science.gov (United States)

    Sundberg, Gale R.

    1990-01-01

    To obtain the Advanced Launch System (ALS) primary goals of reduced costs and improved operability, there must be significant reductions in the launch operations and servicing requirements relative to current vehicle designs and practices. One of the primary methods for achieving these goals is by using vehicle electrical power system and controls for all actuation and avionics requirements. A brief status review of the ALS and its associated Advanced Development Program is presented to demonstrate maturation of those technologies that will help meet the overall operability and cost goals. The electric power and actuation systems are highlighted as a specific technology ready not only to meet the stringent ALS goals (cryogenic field valves and thrust vector controls with peak power demands to 75 hp), but also those of other launch vehicles, military and civilian aircraft, lunar/Martian vehicles, and a multitude of commercial applications.

  10. Renewable Electricity Futures Study. Volume 4: Bulk Electric Power Systems: Operations and Transmission Planning

    Energy Technology Data Exchange (ETDEWEB)

    Milligan, M.; Ela, E.; Hein, J.; Schneider, T.; Brinkman, G.; Denholm, P.

    2012-06-01

    The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%-90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT).

  11. Proposal to Include Electrical Energy in the Industrial Return Statistics

    CERN Document Server

    2003-01-01

    At its 108th session on the 20 June 1997, the Council approved the Report of the Finance Committee Working Group on the Review of CERN Purchasing Policy and Procedures. Among other topics, the report recommended the inclusion of utility supplies in the calculation of the return statistics as soon as the relevant markets were deregulated, without reaching a consensus on the exact method of calculation. At its 296th meeting on the 18 June 2003, the Finance Committee approved a proposal to award a contract for the supply of electrical energy (CERN/FC/4693). The purpose of the proposal in this document is to clarify the way electrical energy will be included in future calculations of the return statistics. The Finance Committee is invited: 1. to agree that the full cost to CERN of electrical energy (excluding the cost of transport) be included in the Industrial Service return statistics; 2. to recommend that the Council approves the corresponding amendment to the Financial Rules set out in section 2 of this docum...

  12. Electric and Hybrid Vehicle Program, Site Operator Program. Quarterly progress report, October--December 1995 (first quarter of fiscal year 1996)

    Energy Technology Data Exchange (ETDEWEB)

    Francfort, J.E. [Lockheed Idaho Technologies Co., Idaho Falls, ID (United States); Bassett, R.R. [Sandia National Labs., Albuquerque, NM (United States); Briasco, S. [Los Angeles Dept. of Water and Power, CA (United States)] [and others

    1996-03-01

    This is the Site Operator Program quarterly report for USDOE electric and hybrid vehicle research. Its mission now includes the three major activity categories of advancement of electric vehicle (EV) technologies, development of infrastructure elements needed to support significant EV use and increasing public awareness and acceptance of EVs. The 11 Site Operator Program participants, their geographic locations, and the principal thrusts of their efforts are identified. The EV inventories of the site operators totals about 250 vehicles. The individual fleets are summarized.

  13. Optimal Wind Power Uncertainty Intervals for Electricity Market Operation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ying; Zhou, Zhi; Botterud, Audun; Zhang, Kaifeng

    2018-01-01

    It is important to select an appropriate uncertainty level of the wind power forecast for power system scheduling and electricity market operation. Traditional methods hedge against a predefined level of wind power uncertainty, such as a specific confidence interval or uncertainty set, which leaves the questions of how to best select the appropriate uncertainty levels. To bridge this gap, this paper proposes a model to optimize the forecast uncertainty intervals of wind power for power system scheduling problems, with the aim of achieving the best trade-off between economics and reliability. Then we reformulate and linearize the models into a mixed integer linear programming (MILP) without strong assumptions on the shape of the probability distribution. In order to invest the impacts on cost, reliability, and prices in a electricity market, we apply the proposed model on a twosettlement electricity market based on a six-bus test system and on a power system representing the U.S. state of Illinois. The results show that the proposed method can not only help to balance the economics and reliability of the power system scheduling, but also help to stabilize the energy prices in electricity market operation.

  14. International Benchmarking of Electricity Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter

    2014-01-01

    Electricity transmission system operators (TSO) in Europe are increasing subject to high-powered performance-based regulation, such as revenue-cap regimes. The determination of the parameters in such regimes is challenging for national regulatory authorities (NRA), since there is normally a single...... TSO operating in each jurisdiction. The solution for European regulators has been found in international regulatory benchmarking, organized in collaboration with the Council of European Energy Regulators (CEER) in 2008 and 2012 for 22 and 23 TSOs, respectively. The frontier study provides static cost...... weight restrictions and a correction method for opening balances....

  15. Hybrid electrical generation system utilizing wind, diesel and hydropower for operation of an underground zinc mine in southern Chile

    Energy Technology Data Exchange (ETDEWEB)

    Gridley, Norman [Minera El Toqui (Chile); Banto, Marcelo [Seawind Chile (Chile)

    2010-07-01

    This paper presents a hybrid electrical generation system used for underground zinc mine operations that utilizes wind, diesel and hydropower. This mine is located in Coyhaique and had a total energy consumption of 32,567 MWh in 2010 which is anticipated to increase by 25% in 2011. Power generation in this mine is independent of the power grid. It consists of four main portals: ventilation, electrical and drainage systems and ramp access to all mining zones. The technical details for all the parts of the mine and the hybrid generation system are given. A tabular form shows the energy consumed every month from 2005-2010 for all three systems involved, namely wind power generation, diesel generation and the hydro generation system. Benefits of this hybrid system include stability and constant power generation under variable loads. This system can also be applied to other mines using a grid. From the study it can be concluded that the hybrid system is environmentally friendly, economical and sustainable.

  16. Electric Vehicles in Logistics and Transportation: A Survey on Emerging Environmental, Strategic, and Operational Challenges

    Directory of Open Access Journals (Sweden)

    Angel Alejandro Juan

    2016-01-01

    Full Text Available Current logistics and transportation (L&T systems include heterogeneous fleets consisting of common internal combustion engine vehicles as well as other types of vehicles using “green” technologies, e.g., plug-in hybrid electric vehicles and electric vehicles (EVs. However, the incorporation of EVs in L&T activities also raise some additional challenges from the strategic, planning, and operational perspectives. For instance, smart cities are required to provide recharge stations for electric-based vehicles, meaning that investment decisions need to be made about the number, location, and capacity of these stations. Similarly, the limited driving-range capabilities of EVs, which are restricted by the amount of electricity stored in their batteries, impose non-trivial additional constraints when designing efficient distribution routes. Accordingly, this paper identifies and reviews several open research challenges related to the introduction of EVs in L&T activities, including: (a environmental-related issues; and (b strategic, planning and operational issues associated with “standard” EVs and with hydrogen-based EVs. The paper also analyzes how the introduction of EVs in L&T systems generates new variants of the well-known Vehicle Routing Problem, one of the most studied optimization problems in the L&T field, and proposes the use of metaheuristics and simheuristics as the most efficient way to deal with these complex optimization problems.

  17. Monitoring of good practices programs and independence for electricity and natural gas system operators. Report 2012

    International Nuclear Information System (INIS)

    2013-09-01

    Electricity and natural gas transmission system operators (TSO) and distribution system operators (DSO) are regulated operators that provide public service functions for the benefit of the network users and the consumers they serve. Accordingly, European and French law requires that they be under independent and nondiscriminatory obligations. In particular, they must develop a good practices program which includes a range of measures to prevent the risk of discriminatory practices in network access. Pursuant to Article L.134-15 of the Energy Code, the Energy Regulatory Commission (CRE) is publishing this year its 8. annual report on the monitoring of good practices programs and independence for electricity and natural gas system operators for the year 2012. This report is based on analysis of the 'reports on the implementation of good practices programs' submitted to the CRE by the operators in late 2012 and audits carried out by the CRE services in these companies in 2012

  18. Monitoring of good practices programs and independence for electricity and natural gas system operators. 2010 report

    International Nuclear Information System (INIS)

    2011-01-01

    Electricity and natural gas transmission system operators (TSO) and distribution system operators (DSO) are regulated operators that provide public service functions for the benefit of the network users and the consumers they serve. Accordingly, European and French law requires that they be under independent and nondiscriminatory obligations. In particular, they must develop a good practices program which includes a range of measures to prevent the risk of discriminatory practices in network access. Pursuant to Article L.134-15 of the Energy Code, the Energy Regulatory Commission (CRE) is publishing this year its 6. annual report on the monitoring of good practices programs and independence for electricity and natural gas system operators for the year 2010. This report is based on analysis of the 'reports on the implementation of good practices programs' submitted to the CRE by the operators in late 2010 and audits carried out by the CRE services in these companies in 2010

  19. Renewable Electricity Futures Study. Volume 4: Bulk Electric Power Systems. Operations and Transmission Planning

    Energy Technology Data Exchange (ETDEWEB)

    Milligan, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ela, Erik [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hein, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Schneider, Thomas [National Renewable Energy Lab. (NREL), Golden, CO (United States); Brinkman, Gregory [National Renewable Energy Lab. (NREL), Golden, CO (United States); Denholm, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-06-15

    The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%–90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT). Learn more at the RE Futures website. http://www.nrel.gov/analysis/re_futures/

  20. Method and system for operating an electric motor

    Science.gov (United States)

    Gallegos-Lopez, Gabriel; Hiti, Silva; Perisic, Milun

    2013-01-22

    Methods and systems for operating an electric motor having a plurality of windings with an inverter having a plurality of switches coupled to a voltage source are provided. A first plurality of switching vectors is applied to the plurality of switches. The first plurality of switching vectors includes a first ratio of first magnitude switching vectors to second magnitude switching vectors. A direct current (DC) current associated with the voltage source is monitored during the applying of the first plurality of switching vectors to the plurality of switches. A second ratio of the first magnitude switching vectors to the second magnitude switching vectors is selected based on the monitoring of the DC current associated with the voltage source. A second plurality of switching vectors is applied to the plurality of switches. The second plurality of switching vectors includes the second ratio of the first magnitude switching vectors to the second magnitude switching vectors.

  1. Operating Experience of Digital, Software-based Components Used in I and C and Electrical Systems in German NPPs

    International Nuclear Information System (INIS)

    Blum, Stefanie; Lochthofen, Andre; Quester, Claudia; Arians, Robert

    2015-01-01

    In recent years, many components in instrumentation and control (I and C) and electrical systems of nuclear power plants (NPPs) were replaced by digital, software-based components. Due to the more complex structure, software-based I and C and electrical components show the potential for new failure mechanisms and an increasing number of failure possibilities, including the potential for common cause failures. An evaluation of the operating experience of digital, software-based components may help to determine new failure modes of these components. In this paper, we give an overview over the results of the evaluation of the operating experience of digital, software-based components used in I and C and electrical systems in NPPs in Germany. (authors)

  2. Methods for the secure and economical operation of inter-connected electrical power systems

    Energy Technology Data Exchange (ETDEWEB)

    Iggland, L. J. E.

    2014-07-01

    This thesis considers aspects of the operation of electric power systems. In particular the focus is on the operation in systems where multiple operators are jointly responsible for the operation of an interconnected system, but where each operator is solely responsible for a sub-system. Due to the manner in which the operation is separated, the operators have detailed information about the subsystem they control, but only limited information about the rest of the system. The market liberalization, and an interest in an integrated pan-European energy market, are leading to increased cross-border power flows. These increased cross-border flows increase the interdependencies between the areas. With increasing interdependencies the problems associated with operators only having limited knowledge about the entire system increase. In order to reduce these issues, which include an inability to properly dispatch generation and being able to perform security analysis, this thesis presents methods which can be used to perform data-exchange without requiring that all information needs to be exchanged. By using repeated exchange of the price and amount of energy traded together with an iterative solution of the local generation dispatch problem, a multi-lateral solution for the interconnected system is achieved. The method is evaluated with respect to how close its solution is to the central one, both for the non-security constrained and the security constrained case. This method is then extended to include HVDC transmission systems. In order to allow the operators to evaluate the effect of contingencies which occur in other areas, the operators must exchange the contingencies which they consider with each other. In order to reduce the amount of data which must be transmitted this thesis proposes a method which summarizes contingencies which are similar into a common one. Thus allowing for a smaller number of contingencies to be considered, without reducing the coverage. This

  3. Methods for the secure and economical operation of inter-connected electrical power systems

    International Nuclear Information System (INIS)

    Iggland, L. J. E.

    2014-01-01

    This thesis considers aspects of the operation of electric power systems. In particular the focus is on the operation in systems where multiple operators are jointly responsible for the operation of an interconnected system, but where each operator is solely responsible for a sub-system. Due to the manner in which the operation is separated, the operators have detailed information about the subsystem they control, but only limited information about the rest of the system. The market liberalization, and an interest in an integrated pan-European energy market, are leading to increased cross-border power flows. These increased cross-border flows increase the interdependencies between the areas. With increasing interdependencies the problems associated with operators only having limited knowledge about the entire system increase. In order to reduce these issues, which include an inability to properly dispatch generation and being able to perform security analysis, this thesis presents methods which can be used to perform data-exchange without requiring that all information needs to be exchanged. By using repeated exchange of the price and amount of energy traded together with an iterative solution of the local generation dispatch problem, a multi-lateral solution for the interconnected system is achieved. The method is evaluated with respect to how close its solution is to the central one, both for the non-security constrained and the security constrained case. This method is then extended to include HVDC transmission systems. In order to allow the operators to evaluate the effect of contingencies which occur in other areas, the operators must exchange the contingencies which they consider with each other. In order to reduce the amount of data which must be transmitted this thesis proposes a method which summarizes contingencies which are similar into a common one. Thus allowing for a smaller number of contingencies to be considered, without reducing the coverage. This

  4. 78 FR 12358 - UBS Financial Services, Inc., Wealth Management Americas Operations, Including On-Site Leased...

    Science.gov (United States)

    2013-02-22

    ..., Inc., Wealth Management Americas Operations, Including On-Site Leased Workers From Leafstone... Services, Inc., Wealth Management Americas Operations (UBS), Weehawken, New Jersey. The workers are engaged... to include all leased workers on-site at UBS Financial Services, Inc., Wealth Management Americas...

  5. Electric power annual 1994. Volume 2, Operational and financial data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-28

    This year, the annual is published in two volumes. Volume I focused on US electric utilities and contained final 1994 data on net generation, fossil fuel consumption, stocks, receipts, and cost. This Volume II presents annual 1994 summary statistics for the electric power industry, including information on both electric utilities and nonutility power producers. Included are preliminary data for electric utility retail sales of electricity, associated revenue, and average revenue per kilowatthour of electricity sold (based on form EIA-861) and for electric utility financial statistics, environmental statistics, power transactions, and demand- side management. Final 1994 data for US nonutility power producers on installed capacity and gross generation, as well as supply and disposition information, are also provided in Volume II. Technical notes and a glossary are included.

  6. Nuclear power plants electrical retrofitting for cost effectiveness, reliability and operating efficiency

    International Nuclear Information System (INIS)

    Ciufu, L.; Popescu, M. O.

    2016-01-01

    In the context of continuous fast growing of the energy demand the current power plants retrofitting concept may represent an important step in the emission reduction, being able to offer in the same time a maximum operating efficiency. This desideratum can be obtained by implementing a rigorous energy management plan, based on an increased energy production capacity of non-pollutant electrical power plants and future-oriented frame on extending their lifetime operation. This management is focused on using state-of-art electronic, electrical and industrial control equipments, which can represent a real key factor. Thus, in this paper an analysis of the electrical system retrofitting is presented. As a part of this research the authors propose and simulate ambitious ways to upgrade actual control and command of the electrical operating systems, by promoting variable speed for large pumps and also computer software, as SCADA, for an intelligent control and monitoring of these studied processes. (authors)

  7. The future frigates of the French navy: all electric ships?

    Energy Technology Data Exchange (ETDEWEB)

    Letot, L. [Delegation Generale pour l' Armement/Direction des Systemes de forces et de la Prospective (DGA/DSP/SASF), 75 - Paris (France); Herjean, Y. [EMM/PL/EPG, France (France)

    2000-07-01

    The application of the all electric ship concept is interesting in the context of several types of warship. Although there it does not pose any major difficulties for simple ships (replenishment ships, amphibious ships) and can be implemented with off-the-shelf technology, its application to combat ships is more ambitious and risky. The renewal of a major part of our frigate fleet in 2008 offers the opportunity to apply this concept. The military and economic advantages have to be demonstrated. Having summarized the programme, the paper discusses the advantages of the all electric concept and examines several areas of technological difficulty that will need to be resolved. Finally, the paper presents work in progress, which will determine whether or not the electric solution is retained for the future multi-mission frigate. (authors)

  8. CANDU operating experience

    International Nuclear Information System (INIS)

    McConnell, L.G.; Woodhead, L.W.; Fanjoy, G.R.; Thurygill, E.W.

    1980-05-01

    The CANDU-PHW program is based upon 38 years of heavy water reactor experience with 35 years of operating experience. Canada has had 72 reactor years of nuclear-electric operations experience with 10 nuclear units in 4 generating stations during a period of 18 years. All objectives have been met with outstanding performance: worker safety, public safety, environmental emissions, reliable electricity production, and low electricity cost. The achievement has been realized through total teamwork involving all scientific disciplines and all project functions (research, design, manufacturing, construction, and operation). (auth)

  9. Competitive electricity markets: One size should fit all

    International Nuclear Information System (INIS)

    Ruff, L.E.

    1999-01-01

    Various market models have been used to try to create competition in the electricity industry in various parts of the world, with varying degrees of success. But every electricity market that has produced reasonably effective and efficient competition has been based on some version of the same generic model. And most of the problems encountered by these markets--apart from problems due to structural flaws such as too few competitors--can be attributed to inconsistent or incomplete application of this basic model concept. In this sense, one size of market model really does fit all--or at least one size should fit all if the objective is to create effective and efficient competition for the benefit of consumers. Effort to slow or reverse the movement to an open spot market integrated with physical dispatch will create complexities and inefficiencies that benefit oligopolists and middlemen at the expense of smaller producers and final consumers

  10. Competitive electricity markets: One size should fit all

    Energy Technology Data Exchange (ETDEWEB)

    Ruff, L.E.

    1999-11-01

    Various market models have been used to try to create competition in the electricity industry in various parts of the world, with varying degrees of success. But every electricity market that has produced reasonably effective and efficient competition has been based on some version of the same generic model. And most of the problems encountered by these markets--apart from problems due to structural flaws such as too few competitors--can be attributed to inconsistent or incomplete application of this basic model concept. In this sense, one size of market model really does fit all--or at least one size should fit all if the objective is to create effective and efficient competition for the benefit of consumers. Effort to slow or reverse the movement to an open spot market integrated with physical dispatch will create complexities and inefficiencies that benefit oligopolists and middlemen at the expense of smaller producers and final consumers.

  11. Operation of Modern Distribution Power Systems in Competitive Electricity Markets

    DEFF Research Database (Denmark)

    Hu, Weihao

    , DG units, loads and electricity price are studied. Further, the effect of energy storage systems will be considered, and an optimal operation strategy for energy storage devices in a large scale wind power system in the electricity market is proposed. The western Danish power system, which has large...... strategy for trading wind power in the Danish short-term electricity market in order to minimize the imbalance costs for regulation. A load optimization method based on spot price for demand side management in Denmark is proposed in order to save the energy costs for 3 types of typical Danish consumers...... maximum profit of the BESS is proposed. Two kinds of BESS, based on polysulfide-bromine (PSB) and vanadium redox (VRB) battery technologies, are studied. Optimal operation strategies of PEV in the spot market are then proposed in order to decrease the energy cost for PEV owners. Furthermore...

  12. Monitoring of good practices programs and independence for electricity and natural gas system operators. Summary report 2011

    International Nuclear Information System (INIS)

    2012-07-01

    Electricity and natural gas transmission system operators (TSO) and distribution system operators (DSO) are regulated operators that provide public service functions for the benefit of the network users and the consumers they serve. Accordingly, European and French law requires that they be under independent and nondiscriminatory obligations. In particular, they must develop a good practices program which includes a range of measures to prevent the risk of discriminatory practices in network access. Pursuant to Article L.134-15 of the Energy Code, the Energy Regulatory Commission (CRE) is publishing this year its 7. annual report on the monitoring of good practices programs and independence for electricity and natural gas system operators for the year 2011. This report is based on analysis of the 'reports on the implementation of good practices programs' submitted to the CRE by the operators in late 2011 and audits carried out by the CRE services in these companies in 2011. These elements were supplemented and clarified by many exchanges with the operators, in particular during the committee hearings that took place in spring 2012 with each network operator. This report is structured around four cross-cutting themes, supplemented by individual analyses of each operator's situation. The cross-cutting issues address communication and user's awareness of the network operators, the new compliance officer function, TSO certification and, finally, the results of the 'mystery shopper' telephone survey carried out by the CRE. The individual situations analysed were those of the eight DSOs serving over 100,000 customers (ERDF, ES, URM, SRD and Geredis-Deux-Sevres for electricity, GrDF, Regaz-Bordeaux and Reseau GDS for natural gas) and the three TSOs (RTE for electricity and GRTgaz and TIGF for natural gas)

  13. Impact Of Secondary-Primary Pumps Operating Sequence On The Electrical Power Supply System

    International Nuclear Information System (INIS)

    Suwoto; Rusdiyanto; Kiswanto

    2001-01-01

    The operating procedure of the reactor cooling system has decided that the primary cooling pump should be operated before secondary cooling pump as known primary-secondary pumps operating sequence. This decision is based on consideration that starting current of the primary pump is higher than secondary pump. Therefore, the primary-secondary pumps operating sequence can avoid the power supply system failure. However, this operating procedure has to take a consequence that in case of primary pump failure, the shutdown time period of the reaktor to be longer caused to re operate the primary pump has required that the running secondary pump should be shutted off. To solve this problem, an impact analysis of the secondary-primary pumps operating sequence on the electric power supply system was carried out to identify the revision possibility of the cooling pump operating procedure. The analysis by discussion of the measuring results of the secondary and primary pump starting current related to another electrical loads has been measured. From discussion it can be concluded that secondary-primary pumps operating sequence has no impact to failure in electric power supply system

  14. Coordinated Operation of the Electricity and Natural Gas Systems with Bi-directional Energy Conversion

    DEFF Research Database (Denmark)

    Zeng, Qing; Zhang, Baohua; Fang, Jiakun

    2017-01-01

    A coordinated operation of the natural gas and electricity network with bi-directional energy conversion is expected to accommodate high penetration levels of renewables. This work focuses on the unified optimal operation of the integrated natural gas and electricity system considering the network...

  15. The structure and operation of the privatised UK electricity supply industry

    International Nuclear Information System (INIS)

    Kerss, W.

    1991-01-01

    The National Grid Company has just over a years experience in running the England and Wales Grid System as a public limited company (plc) in a market led environment. The industry has been restructured for privatisation with NGC Holdings, owner of NGC plc, being jointly owned by the 12 Regional Electricity Companies. The successful flotation of the 12 Regional Electricity Companies at the end of 1990 included the businesses and assets of NGC. The role of NGC is twofold; firstly to operate and maintain the HV transmission grid for England and Wales and secondly to facilitate competition in the market for electricity. To meet the requirements for facilitating competition NGC is responsible for the arrangements which will enable new players to enter the market. Under its Transmission Licence NGC has to respond swiftly to a request for connections and the charges levied must be seen to be fair. The publishing of service charges and opportunities identified in the Seven Year Statement enable existing and potential users of the Grid System to identify new connection opportunities. To ensure impartiality in its operation, the pooling and settlement system is administered NGC Settlements Limited, a wholly owned subsidiary of NGC, with strict rules on commercial security. Separate in-house businesses have also been set up to administer the other commercial activities of NGC; the Pumped Storage Business, the Interconnection Business (France and Scotland) and the Ancillary Services Business for the provision of system reserve and other services to ensure the stability and security of the system. (author)

  16. Analysis of electric energy consumption of automatic milking systems in different configurations and operative conditions.

    Science.gov (United States)

    Calcante, Aldo; Tangorra, Francesco M; Oberti, Roberto

    2016-05-01

    Automatic milking systems (AMS) have been a revolutionary innovation in dairy cow farming. Currently, more than 10,000 dairy cow farms worldwide use AMS to milk their cows. Electric consumption is one of the most relevant and uncontrollable operational cost of AMS, ranging between 35 and 40% of their total annual operational costs. The aim of the present study was to measure and analyze the electric energy consumption of 4 AMS with different configurations: single box, central unit featuring a central vacuum system for 1 cow unit and for 2 cow units. The electrical consumption (daily consumption, daily consumption per cow milked, consumption per milking, and consumption per 100L of milk) of each AMS (milking unit + air compressor) was measured using 2 energy analyzers. The measurement period lasted 24h with a sampling frequency of 0.2Hz. The daily total energy consumption (milking unit + air compressor) ranged between 45.4 and 81.3 kWh; the consumption per cow milked ranged between 0.59 and 0.99 kWh; the consumption per milking ranged between 0.21 and 0.33 kWh; and the consumption per 100L of milk ranged between 1.80 to 2.44 kWh according to the different configurations and operational contexts considered. Results showed that AMS electric consumption was mainly conditioned by farm management rather than machine characteristics/architectures. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Probabilistic Steady-State Operation and Interaction Analysis of Integrated Electricity, Gas and Heating Systems

    Directory of Open Access Journals (Sweden)

    Lun Yang

    2018-04-01

    Full Text Available The existing studies on probabilistic steady-state analysis of integrated energy systems (IES are limited to integrated electricity and gas networks or integrated electricity and heating networks. This paper proposes a probabilistic steady-state analysis of integrated electricity, gas and heating networks (EGH-IES. Four typical operation modes of an EGH-IES are presented at first. The probabilistic energy flow problem of the EGS-IES considering its operation modes and correlated uncertainties in wind/solar power and electricity/gas/heat loads is then formulated and solved by the Monte Carlo method based on Latin hypercube sampling and Nataf transformation. Numerical simulations are conducted on a sample EGH-IES working in the “electricity/gas following heat” mode to verify the probabilistic analysis proposed in this paper and to study the effects of uncertainties and correlations on the operation of the EGH-IES, especially uncertainty transmissions among the subnetworks.

  18. Implementing energy efficiency: Challenges and opportunities for rural electric co-operatives and small municipal utilities

    International Nuclear Information System (INIS)

    Wilson, Elizabeth J.; Plummer, Joseph; Fischlein, Miriam; Smith, Timothy M.

    2008-01-01

    Challenges in implementing demand side management (DSM) programs in rural electric co-operatives and small municipal utilities are not well understood, yet these organizations sell roughly 15% of electricity in the US, many are more coal-intensive than investor-owned utilities (IOUs), and they are politically important-rural electric co-operatives cover about 75% of the US land area and municipal utilities are found in every state except Hawaii. We provide a background on rural co-operatives and municipal utilities in the context of the US electric sector and highlight the challenges and opportunities of implementing DSM programs in these institutions. Where past studies of utility DSM have mostly focused on IOUs or consisted of qualitative case studies of municipal utilities with exemplary DSM performance, this study makes a unique contribution to the DSM literature by systematically analyzing an entire co-operative and municipal utility population in Minnesota through the use of a survey. In doing so, we provide policy recommendations relevant to energy planners and policy makers to support DSM in rural electric co-operatives and municipal utilities

  19. Survey on severity of magnetic and electric fields around video display terminals and its association with health effects on operators

    Directory of Open Access Journals (Sweden)

    F. Rezaee

    2009-10-01

    Full Text Available Background and aimsIntensity of Magnetic and Electric fields around visual displayterminals and its association on health effects were studied.Methodsmagnetic and electric fields intensities around 237 VDTs at distances 30¡50¡ 60 cm and different operating conditions (active¸ screen saver¸ shut down with use of HI-3603 device  according to Svensk standard method were monitored. Resultsmagnetic and electric fields Intensities at 30 cm were higher than standard and at 50 cm Monitors in all measurements were lower than standard (20mA/m MPRII, TCO and (1V/m,TCO Magnetic fields intensities of LCD monitors in rare side were higher than all other directionsand rise versa intensities of magnetic fields of cathodiC monitors were in front than other sides. Differences of magnetic and electric fields intensities were not significant in various operating conditions (screen saver and active operation. Comparison of chronic syndrome of  exhaustion in two groups of case and control, demonstrated higher of prevalence of symptoms such as shedding  tears, eye irritation and fatigue in case rather than control group.Conclusionat time of procurement of monitors TCO standard label should be noticed. During recess times, monitors should be turned off in order to reduce exposure to electric and magnetic  fields.

  20. Feasibility study on economic operation of wind farms in the electric power system of the Republic of Croatia

    International Nuclear Information System (INIS)

    Rabadan, L.P.; Sansevic, M.; Klarin, B.

    1996-01-01

    In this work are analyzed island and coastal locations on the Adriatic Sea as possible sites of wind farms. The analysis is based on the expert system developed by authors of other literature. The macrolocation selection is performed by the multicriterial decision-making method and in compliance with the current world approach to their wind potential and some other criteria. The choice of wind turbine generator (WTG) unit is based on the fundamental criteria: operational efficiency on the given location, price per installed kW, and price of the generated electricity. The results obtained in this study show that the contribution in electricity yield from the selected wind power plants could amount to 4.33% of the electricity generated by the Croatian power plants in the year 1990. The calculations of electricity costs are based on the quantity of electricity obtained by simulating the operation of the best WTG units selected from the ES database and including other influential factors. In the choice of macrolocations and WTG units the fuzzy method is implemented as part of the ES. (author)

  1. Electricity Networks: Infrastructure and Operations. Too complex for a resource?

    Energy Technology Data Exchange (ETDEWEB)

    Volk, Dennis

    2013-07-01

    Electricity security remains a priority of energy policy and continuous electrification will further enhance the importance in the years to come. Market liberalisation has brought substantial benefits to societies, including competition, innovation, more client-oriented services and the reduced needs for public expenditure. Further, the path of decarbonisation is a must but experiences with many new technologies and policies show their many implications on power systems. Electricity networks form the backbone of reliable and affordable power systems and also significantly support the inception of renewable generation. The importance of distribution and transmission networks has to be well understood by policy makers and regulators to maintain the sensitive balance within the policy triangle of reliability, affordability and sustainability as power systems rapidly change. Failures in choosing the right institutions and regulatory frameworks to operate and build networks will put the sensitive balance within the policy triangle at risk. ''Too complex for a resource?'' identifies the key challenges the electricity distribution and transmission networks face today and in the future. It further provides for best practice examples on institutional design choices and regulatory frameworks for sound network service provision but also highlights the importance of additional responses required. More market-based and dynamic frameworks for various system services, the growing need for active service participation of renewable generators and highly independent and transparent central operators seem to be at the heart of these responses. ''Too complex for a resource?'' finds that the answer to the challenges ahead is not always more infrastructure and that networks and the services they provide have to be regarded as equal part of the total power system. Thus, accurate and dynamic cost allocation can significantly support to transform

  2. Physics-Based Modeling of Electric Operation, Heat Transfer, and Scrap Melting in an AC Electric Arc Furnace

    Science.gov (United States)

    Opitz, Florian; Treffinger, Peter

    2016-04-01

    Electric arc furnaces (EAF) are complex industrial plants whose actual behavior depends upon numerous factors. Due to its energy intensive operation, the EAF process has always been subject to optimization efforts. For these reasons, several models have been proposed in literature to analyze and predict different modes of operation. Most of these models focused on the processes inside the vessel itself. The present paper introduces a dynamic, physics-based model of a complete EAF plant which consists of the four subsystems vessel, electric system, electrode regulation, and off-gas system. Furthermore the solid phase is not treated to be homogenous but a simple spatial discretization is employed. Hence it is possible to simulate the energy input by electric arcs and fossil fuel burners depending on the state of the melting progress. The model is implemented in object-oriented, equation-based language Modelica. The simulation results are compared to literature data.

  3. Enhanced Operation of Electricity Distribution Grids Through Smart Metering PLC Network Monitoring, Analysis and Grid Conditioning

    Directory of Open Access Journals (Sweden)

    Iker Urrutia

    2013-01-01

    Full Text Available Low Voltage (LV electricity distribution grid operations can be improved through a combination of new smart metering systems’ capabilities based on real time Power Line Communications (PLC and LV grid topology mapping. This paper presents two novel contributions. The first one is a new methodology developed for smart metering PLC network monitoring and analysis. It can be used to obtain relevant information from the grid, thus adding value to existing smart metering deployments and facilitating utility operational activities. A second contribution describes grid conditioning used to obtain LV feeder and phase identification of all connected smart electric meters. Real time availability of such information may help utilities with grid planning, fault location and a more accurate point of supply management.

  4. Electricity pricing: optimal operation and investment by industrial consumers

    Energy Technology Data Exchange (ETDEWEB)

    Outhred, H.R.; Kaye, R.J.; Sutanto, D.; Manimaran, R.; Bannister, C.H.; Lee, Y.B.

    1988-08-01

    Ongoing research in the areas of economically efficient electricity pricing and industrial consumer response is described. A new electricity pricing theory is described that incorporates future uncertainty and intertemporal linkages between decisions. It indicates that electricity prices should contain two terms - short-run marginal cost plus a term that reflects how each particular decision is likely to affect future global welfare. A practical implementation using spot prices and forward contracts plus financial instruments for risk sharing and decision coordination is explored, and a procedure for developing long-term pricing policy is considered. The operation of industrial plant has been investigated and models developed to optimize plant behaviour in response to spot prices and forward contracts for electricity. These models are described and results of simulation studies discussed. The economic efficiency and risk sharing advantages of this advanced tariff structure compared with a conventional time-of-use tariff are illustrated.

  5. ABWR-II Core Design with Spectral Shift Rods for Operation with All Control Rods Withdrawn

    International Nuclear Information System (INIS)

    Moriwaki, Masanao; Aoyama, Motoo; Anegawa, Takafumi; Okada, Hiroyuki; Sakurada, Koichi; Tanabe, Akira

    2004-01-01

    An innovative reactor core concept applying spectral shift rods (SSRs) is proposed to improve the plant economy and the operability of the 1700-MW(electric) Advanced Boiling Water Reactor II (ABWR-II). The SSR is a new type of water rod in which a water level is naturally developed during operation and changed according to the coolant flow rate through the channel. By taking advantage of the large size of the ABWR-II bundle, the enhanced spectral shift operation by eight SSRs allows operation of the ABWR-II with all control rods withdrawn. In addition, the uranium-saving factor of 6 to 7% relative to the reference ABWR-II core with conventional water rods can be expected due to the greater effect of spectral shift. The combination of these advantages means the ABWR-II with SSRs should be an attractive alternative for the next-generation nuclear reactor

  6. 76 FR 58101 - Electric Reliability Organization Interpretation of Transmission Operations Reliability Standard

    Science.gov (United States)

    2011-09-20

    ....C. Cir. 2009). \\4\\ Mandatory Reliability Standards for the Bulk-Power System, Order No. 693, FERC... for maintaining real and reactive power balance. \\14\\ Electric Reliability Organization Interpretation...; Order No. 753] Electric Reliability Organization Interpretation of Transmission Operations Reliability...

  7. Evaluation of sounds for hybrid and electric vehicles operating at low speed

    Science.gov (United States)

    2012-10-22

    Electric vehicles (EV) and hybrid electric vehicles (HEVs), operated at low speeds may reduce auditory cues used by pedestrians to assess the state of nearby traffic creating a safety issue. This field study compares the auditory detectability of num...

  8. Integrating wind output with bulk power operations and wholesale electricity markets

    International Nuclear Information System (INIS)

    Hirst, E.

    2002-01-01

    Wind farms have three characteristics that complicate their widespread application as an electricity resource: limited control, unpredictability and variability. Therefore the integration of wind output into bulk power electric systems is qualitatively different from that of other types of generators. The electric system operator must move other generators up or down to offset the time-varying wind fluctuations. Such movements raise the costs of fuel and maintenance for these other generators. Not only is wind power different, it is new. The operators of bulk power systems have limited experience in integrating wind output into the larger system. As a consequence, market rules that treat wind fairly - neither subsidizing nor penalizing its operation - have not yet been developed. The lack of data and analytical methods encourages wind advocates and sceptics to rely primarily on their biases and beliefs in suggesting how wind should be integrated into bulk power systems. This project helps fill this data and analysis gap. Specifically, it develops and applies a quantitative method for the integration of a wind resource into a large electric system. The method permits wind to bid its output into a short-term forward market (specifically, an hour-ahead energy market) or to appear in real time and accept only intrahour and hourly imbalance payments for the unscheduled energy it delivers to the system. Finally, the method analyses the short-term (minute-to-minute) variation in wind output to determine the regulation requirement the wind resource imposes on the electrical system. (author)

  9. Is an all-electric society possible? BIP-Enerpresse debate, July 7, 2009

    International Nuclear Information System (INIS)

    2009-01-01

    This paper is a synthesis of a debate where interveners were asked whether an all-electric society was desirable or possible. According to them, the share of electricity will increase, notably under the influence of developing countries. They comment the possible evolutions of the energy mix, the development of electric vehicles, and the transfer towards electricity in several sectors (transport, industry, and building) by giving up fossil energies. They outline the problem of storage of electricity, particularly in the perspective of the development of electric vehicles. Some other issues are discussed like the reduction of the residential energy consumption, the renewing of residential fuel heating systems

  10. Experience of electric power conservation in COELBA (Bahia Electric Company)

    International Nuclear Information System (INIS)

    Bastos, A.C.F.

    1990-01-01

    The electric power crisis of Brazilian north-east in 1987 imposes the Bahia Electric Company-COELBA to management a electric power conservation. The institutional, organizational and operational aspects are presented, including the tariff system, the market, the consumption and the relation with public. (author)

  11. Norwegian electricity market liberalisation: questions of cost calculation and price definition by grid operators

    International Nuclear Information System (INIS)

    Wild, J.; Vaterlaus, S.

    2002-01-01

    This report for the Swiss Federal Office of Energy (SFOE) presents the results of a study carried out on the Norwegian electricity market 10 years after its liberalisation. The similarity of the Norwegian market to the Swiss electricity market is discussed. Similarly to the proposed situation in Switzerland, the liberalisation in Norway foresaw no privatisation of public utilities and a model for the regulation of grid access was introduced. The report describes and comments on the various phases in which the liberalisation occurred and examines the various instruments used, e.g. to ensure that individual grid operators did not make undue profits from their monopoly. The methods used for the monitoring of grid operators' costs are described and the mechanisms involved in the definition of prices for grid services are examined, including measures taken when profits were too high or too low. The report is concluded with a discussion of the conclusions that can be drawn from the Norwegian model for Swiss market opening efforts

  12. Optical and electrical properties of Cu-based all oxide semi-transparent photodetector

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hong-Sik; Patel, Malkeshkumar; Yadav, Pankaj; Kim, Joondong, E-mail: joonkim@inu.ac.kr, E-mail: dwkim@ewha.ac.kr [Photoelectric and Energy Device Application Lab (PEDAL) and Department of Electrical Engineering, Incheon National University, 119 Academy Rd., Yeonsu, Incheon 406772 (Korea, Republic of); Sohn, Ahrum; Kim, Dong-Wook, E-mail: joonkim@inu.ac.kr, E-mail: dwkim@ewha.ac.kr [Department of Physics, Ewha Womans University, Seoul 120750 (Korea, Republic of)

    2016-09-05

    Zero-bias operating Cu oxide-based photodetector was achieved by using large-scale available sputtering method. Cu oxide (Cu{sub 2}O or CuO) was used as p-type transparent layer to form a heterojunction by contacting n-type ZnO layer. All metal-oxide materials were employed to realize transparent device at room temperature and showed a high transparency (>75% at 600 nm) with excellent photoresponses. The structural, morphological, optical, and electrical properties of Cu oxides of CuO and Cu{sub 2}O are evaluated in depth by UV-visible spectrometer, X-ray diffraction, scanning electron microscopy, atomic force microscopy, Kelvin probe force microscopy, and Hall measurements. We may suggest a route of high-functional Cu oxide-based photoelectric devices for the applications in flexible and transparent electronics.

  13. 2008 report on the Monitoring of good practices programs and independence for electricity and natural gas system operators

    International Nuclear Information System (INIS)

    2009-01-01

    Electricity and natural gas transmission system operators (TSO) and distribution system operators (DSO) are regulated operators that provide public service functions for the benefit of the network users and the consumers they serve. Accordingly, European and French law requires that they be under independent and nondiscriminatory obligations. In particular, they must develop a good practices program which includes a range of measures to prevent the risk of discriminatory practices in network access. Pursuant to Article L.134-15 of the Energy Code, the Energy Regulatory Commission (CRE) is publishing this year its 4. annual report on the monitoring of good practices programs and independence for electricity and natural gas system operators for the year 2008. This report is based on analysis of the 'reports on the implementation of good practices programs' submitted to the CRE by the operators in late 2008 and audits carried out by the CRE services in these companies in 2008

  14. Mode of operation and performance of a simulation model for the electricity management

    International Nuclear Information System (INIS)

    Weible, H.

    1981-01-01

    In the first two main parts of this report the structure of a simulation model to define the consequences of decisions in the electricity supply sector is explained, based on a careful revision of relevant problems. By means of the system analysis the model represents an attempt to describe all essential relations between the electricity demand on the one hand and the consequences of the generation of electricity (indluding transport) for consumers, state, environment, market of capital and fuel on the other hand. The multifarious ways of operation and application of the model are demonstrated taking the public electricity management of Baden-Wuerttemberg as an example. Besides a validation of the model for 1970 to 1977, possible trends until the year 2000 are shown. As an essential result of the analyses it can be shown, that a renunciation on the further extension of nuclear energy turns out to be unrealistic by a supposed average increase of the electricity demand of 4% p.a.. A comparison of different model conceptions shows, that the information loss, which proceeds from the approximation of year-load-curves, leads to important deviations in the model results. According to the sensitivity analyses the increase of the electricity consumption turns out to be the most essential influence on the time dependent results. (orig./UA) [de

  15. A Study of Torque Vectoring and Traction Control for an All-Wheel Drive Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Maharun Mui’nuddin

    2014-07-01

    Full Text Available Common vehicle always experience energy loss during cornering manoeuver. Thus, to ensure it did not happened especially at high speed, a study of torque vectoring and traction control need to be made since it can increase the traction control of tyres during cornering at high speed. The study of torque vectoring and traction control for an all-wheel drive electric vehicle was conducted by modelling an all-wheel drive electric vehicle (EV in ADAMS/Car software. In addition, an optimal control algorithm will be developed for best performance to minimize energy losses using MATLAB/Simulink software. Furthermore, to prove the effectiveness of the all-wheel drive electric, the torque and traction control simulation of the all-wheel drive electric vehicle will be compared with uncontrolled electric vehicle model. According to the result, torque vectoring and traction control of in-wheel motor in all wheel drive EV can help to increase the performance of the electric vehicle during cornering manoeuver. In conclusion, this study of torque vectoring and traction control for an all-wheel drive electric vehicle will help researchers to improve the design of the future electric vehicle in term of the vehicle performance during cornering manoeuvre.

  16. Glass science tutorial: Lecture number-sign 2, Operating electric glass melters. James N. Edmonson, Lecturer

    International Nuclear Information System (INIS)

    Kruger, A.A.

    1994-10-01

    This report contains basic information on electric furnaces used for glass melting and on the properties of glass useful for the stabilization of radioactive wastes. Furnace nomenclature, furnace types, typical silicate glass composition and properties, thermal conductivity information, kinetics of the melting process, glass furnace refractory materials composition and thermal conductivity, and equations required for the operation of glass melters are included

  17. CLINICAL STUDY OF ELECTRICAL BURNS AMONG ALL BURNS CASES- 3 YEARS’ EXPERIENCE

    Directory of Open Access Journals (Sweden)

    Nagabathula Durga Prasad

    2017-08-01

    Full Text Available BACKGROUND With the advances in technology, electrical injuries are becoming more common and are the leading cause of work-related traumatic death. One third of all electrical traumas and most high-voltage injuries are job related and more than 50% of these injuries result from power line contact. The management of the major burn injury represents a significant challenge to every member of the burns team. Most of electrical burns present with gangrene of toes and limbs with eschar over body parts. Their presentation is mostly due to contact with high-voltage electricity at their work places. MATERIALS AND METHODS A retrospective study was made to study the clinico-social profile of patients suffering electric burns admitted into Department of General Surgery. RESULTS 92 cases were evaluated and studied. Majority of patients developed gangrene of limbs and toes. Amputations and skin grafting was done. Most patients who suffered electric burns were males of age group 21 to 40 years. All cases are accidental and mostly occurred at work places. Most electric burns are high-voltage based and caused deep burns. Major complications like acute renal failure and septicaemia were encountered. Most of them suffered 16 to 30% burns. Most commonly isolated organism from wounds is pseudomonas. Most of them suffered a hospital stay of 1 to 2 months. CONCLUSION Electric burns are a burden to the society. Prevention is the best way to deal with them. Electricity-based employees have to be trained properly regarding safety measures to be taken. General education of public regarding safety measures can prevent electrical burn injuries.

  18. Nuclear power within liberalised electricity markets

    International Nuclear Information System (INIS)

    Kidd, Stephen W.

    2002-01-01

    Competition between various methods of generating electricity in liberalised markets means that all power plants must be cost-effective. The price of electricity from nuclear power includes all waste disposal and decommissioning costs, unlike other electricity generating technologies. Most existing nuclear power plants are likely to prosper under electricity liberalization. Many will receive operating life extensions and be able to compete in the electricity market for many years to come. Investment costs are particularly heavy for nuclear plants. Capital expenditure appraisal methodologies mean that such plants suffer financial disadvantages in times of high interest rates. Low and stable fuel costs are the prime advantage of nuclear plants against other sources of generating electricity. There will be significant demand for new generating capacity, both incremental and replacement, in the next 20 years. Under present conditions, where there is access to a stable and cheap supply of piped gas, nuclear and coal plants find it difficult to compete against gas-fired plants. The nuclear industry is addressing the need for new reactor designs, offering significant capital and operating cost reductions from the previous generation of reactors. This development and the need for carbon abatement on a worldwide basis offers nuclear plants a further economic advantage against alternative technologies. (author)

  19. A Kantorovich Type of Szasz Operators Including Brenke-Type Polynomials

    Directory of Open Access Journals (Sweden)

    Fatma Taşdelen

    2012-01-01

    convergence properties of these operators by using Korovkin's theorem. We also present the order of convergence with the help of a classical approach, the second modulus of continuity, and Peetre's -functional. Furthermore, an example of Kantorovich type of the operators including Gould-Hopper polynomials is presented and Voronovskaya-type result is given for these operators including Gould-Hopper polynomials.

  20. Impact of Deficient Electricity Supply on the Operations of Small Scale Businesses in North East Nigeria

    Directory of Open Access Journals (Sweden)

    Ahmed Ado

    2015-03-01

    Full Text Available Electricity supply in Nigeria is often erratic. Consumers of electricity (residential, commercial and industrial consumers suffer untold hardships as the State Owned Enterprise; the Power Holding Company of Nigeria (PHCN has been unable to supply reliable power. This is despite massive injections of funds by the Federal Government into the operations of the company over recent years. The failure has significantly impacted negatively on the operations of the business sector especially the small scale subsector that operates with little capital and are thus in most cases unable to afford a back-up facility to ensure un-interrupted power supply for their operations. The study examined the impact of deficient electric power supply on the operations of small scale businesses operating in north east of Nigeria. From the population of small scale businesses, a sample was selected through the use of stratified random sampling to ensure the effective representation of the population of small scale businesses in north east Nigeria. Results from data analysis indicates the severity of electricity supply outages and the costs imposed by power supply outages on the operation of this class of businesses in the region. The paper therefore recommends the need for policy attention towards revitalizing the electricity sector of Nigeria for enhanced supply of electricity to the national economy. When this is achieved, the small business sub-sector will be in a position to effectively lead in the drive towards industrializing the Nigerian economy.

  1. Transport and operation of Spanish electrical system; El transporte y la operacion del sistema electrico en Espana

    Energy Technology Data Exchange (ETDEWEB)

    Mielgo Alvarez, P.

    1998-12-01

    The article summarized the institutional organization of the electric sector in Spain during recent years, up to the deregulation phase initial by the Electricity Sector Act. approved in november 1997. It includes a review of the regulation an retribution of the transmission, system operation and network management activities, as well as a description of the development and capabilities of Red Electrica as the company to which these central functions are assigned, and also of the legal limitations, and the opportunities opened by the new legal framework. (Author)

  2. Safety and operational aspects in in-situ electrical baking of large vacuum systems of Indus accelerators

    International Nuclear Information System (INIS)

    Bhatnagar, Prateek; Bhange, Nilesh; Joshi, Sujata; Sridhar, R.

    2016-01-01

    In order to achieve pressures in UHV (Ultra High Vacuum) range, the vacuum chambers and associated vacuum components, necessarily made of UHV compatible materials, should be baked sufficiently long enough so as to reduce outgassing rates. The baking period usually ranges from 48 hours to 72 hours for an electrical load of more than 30 kW per sector, in which baking temperatures, a characteristic parameter and specific to material, range from 150°C-180°C for Aluminium alloy and 250°C-300°C for SS (stainless steel). Indus accelerators vacuum installations include more than 300 m long vacuum chamber which are subjected to rigorous, standardized and labour intensive electrical baking procedure involving an intelligent ON-OFF distributed temperature control system with in-built defence of electrical safety and expandability as per the needs. The paper discusses various in built electrical safely features, operational aspects, work practices and challenges involved in accomplishing an interrupt free continuous electrical baking for distributed electrical load of more than 30 kW for a typical vacuum segment of Indus accelerator. (author)

  3. Electric- and magnetic-dipole contributions to a theory of radiation reaction field and atom self-energy: An operator reaction field

    International Nuclear Information System (INIS)

    Obada, A.S.F.; Mahran, M.H.

    1982-08-01

    The consequences of including magnetic-dipole contributions, besides the electric-dipole, are considered in the operators for the radiation field. The Bloch equations which describe the two-level atom operators are modified. These equations together with the field operators are discussed, and the contributions are manifested. The spectrum for spontaneous emission and a generalized dynamical Stark effect are obtained. Rabi frequency is modified. (author)

  4. Modeling Electric Double-Layers Including Chemical Reaction Effects

    DEFF Research Database (Denmark)

    Paz-Garcia, Juan Manuel; Johannesson, Björn; Ottosen, Lisbeth M.

    2014-01-01

    A physicochemical and numerical model for the transient formation of an electric double-layer between an electrolyte and a chemically-active flat surface is presented, based on a finite elements integration of the nonlinear Nernst-Planck-Poisson model including chemical reactions. The model works...... for symmetric and asymmetric multi-species electrolytes and is not limited to a range of surface potentials. Numerical simulations are presented, for the case of a CaCO3 electrolyte solution in contact with a surface with rate-controlled protonation/deprotonation reactions. The surface charge and potential...... are determined by the surface reactions, and therefore they depends on the bulk solution composition and concentration...

  5. Operating principle of Soft Open Points for electrical distribution network operation

    International Nuclear Information System (INIS)

    Cao, Wanyu; Wu, Jianzhong; Jenkins, Nick; Wang, Chengshan; Green, Timothy

    2016-01-01

    Highlights: • Two control modes were developed for a B2B VSCs based SOP. • The SOP operating principle was investigated under various network conditions. • The performance of the SOP using two control modes was analyzed. - Abstract: Soft Open Points (SOPs) are power electronic devices installed in place of normally-open points in electrical power distribution networks. They are able to provide active power flow control, reactive power compensation and voltage regulation under normal network operating conditions, as well as fast fault isolation and supply restoration under abnormal conditions. Two control modes were developed for the operation of an SOP, using back-to-back voltage-source converters (VSCs). A power flow control mode with current control provides independent control of real and reactive power. A supply restoration mode with a voltage controller enables power supply to isolated loads due to network faults. The operating principle of the back-to-back VSCs based SOP was investigated under both normal and abnormal network operating conditions. Studies on a two-feeder medium-voltage distribution network showed the performance of the SOP under different network-operating conditions: normal, during a fault and post-fault supply restoration. During the change of network operating conditions, a mode switch method based on the phase locked loop controller was used to achieve the transitions between the two control modes. Hard transitions by a direct mode switching were noticed unfavourable, but seamless transitions were obtained by deploying a soft cold load pickup and voltage synchronization process.

  6. Annual report on the Monitoring of good practices programs and independence for electricity and natural gas system operators - 2006

    International Nuclear Information System (INIS)

    2007-01-01

    Electricity and natural gas transmission system operators (TSO) and distribution system operators (DSO) are regulated operators that provide public service functions for the benefit of the network users and the consumers they serve. Accordingly, European and French law requires that they be under independent and nondiscriminatory obligations. In particular, they must develop a good practices program which includes a range of measures to prevent the risk of discriminatory practices in network access. Pursuant to Article L.134-15 of the Energy Code, the Energy Regulatory Commission (CRE) is publishing this year its 2. annual report on the monitoring of good practices programs and independence for electricity and natural gas system operators for the year 2006. This report is based on analysis of the 'reports on the implementation of good practices programs' submitted to the CRE by the operators in late 2006 and audits carried out by the CRE services in these companies in 2006

  7. Annual report on the Monitoring of good practices programs and independence for electricity and natural gas system operators - 2007

    International Nuclear Information System (INIS)

    2008-01-01

    Electricity and natural gas transmission system operators (TSO) and distribution system operators (DSO) are regulated operators that provide public service functions for the benefit of the network users and the consumers they serve. Accordingly, European and French law requires that they be under independent and nondiscriminatory obligations. In particular, they must develop a good practices program which includes a range of measures to prevent the risk of discriminatory practices in network access. Pursuant to Article L.134-15 of the Energy Code, the Energy Regulatory Commission (CRE) is publishing this year its 3. annual report on the monitoring of good practices programs and independence for electricity and natural gas system operators for the year 2007. This report is based on analysis of the 'reports on the implementation of good practices programs' submitted to the CRE by the operators in late 2007 and audits carried out by the CRE services in these companies in 2007

  8. The impact of the year 2000 issue on electricity grid performance and nuclear power plant operation in Bulgaria, the Russian Federation and Slovakia

    International Nuclear Information System (INIS)

    1999-07-01

    The Y2K date conversion is a potential source of problems to the operation of nuclear power plants through external events and interfaces with electrical power systems, telecommunication systems, and other supporting infrastructures, even if diagnostic and corrective actions within the plant itself, both planned or implemented, are successful. At the end of 1998 there were 425 nuclear power plants in operation in 31 Member States. Most countries and regions are conducting intensive diagnostic and corrective activities to 'find and fix' Y2K software (including embedded software) and equipment problems in their nuclear power plants. These efforts are supplemented by contingency plans. Other countries and regions have not been making comparable efforts and are relying mainly on contingency planning and preparedness. Results of diagnostic and corrective activities can be of benefit to all Member States. Activities on 'find and fix' Y2K problems in electricity grid control systems and computer related technology in national and regional dispatch centers could be of considerable benefit due to the widespread use of the same components, equipment, and software. Consistent with the objectives of the International Atomic Energy Agency's Y2K program, an experts meeting was convened to collect information on Y2K activities related to grid operation in countries that operate nuclear power plants and also to identify specific actions to be taken and issues to be addressed in connection with expected grid disturbances. The countries of eastern Europe and the Russian Federation were considered to be a very important region due to delays in taking Y2K corrective actions but also due to the similarity of their electricity grid systems both in components and design but also in mode of operation. Most of these countries either operate their own nuclear power plants or are linked through their electricity grid interconnections to a neighboring country that operates nuclear power

  9. Power for all? Electricity and uneven development in North Carolina

    Science.gov (United States)

    Harrison, Conor M.

    Many towns in eastern North Carolina face a number of challenges common to the rural South, including high rates of poverty and diminishing employment opportunities. However, some residents of this region also confront a unique hardship---electricity prices that are vastly higher than those of surrounding areas. This dissertation examines the origins of pricing inequalities in the electricity market of eastern North Carolina---namely how such inequalities developed and their role in the production of racial and economic disparities in the South. This dissertation examines the evolving relations between federal and state agencies, corporations, and electric utilities, and asks why these interactions produced varying social outcomes across different places and spatial settings. The research focuses on the origins and subsequent development of electric utilities in eastern North Carolina, and examines how electricity as a material technology interacted with geographies of race and class, as well as the dictates of capital accumulation. This approach enables a rethinking of several concepts that are rarely examined by scholars of electric utilities, most notably the monopoly service territory, which I argue served as a spatial fix to accumulation problems in the industry. Further, examining the way that electric utilities developed in North Carolina during the 20th century brings to the forefront the at times contradictory relationships among systems of electricity provision, Jim Crow segregation, the Progressive Era, and the New Deal. Such a focus highlights the important role that the control of electricity provision played in shaping racial inequalities that continue to persist in the region. With most urban areas were electrified in the 1930s, the research also traces the electricity distribution lines as they moved out of cities through rural electrification programs, a shift that highlights the state as a multi-scalar and variegated actor that both aided and

  10. Legal aspects of electric power supply. Grid operator obligations between entrepreneurial responsibility and state control; Das Recht der Elektrizitaetsversorgungsnetze. Netzbetreiberpflichten zwischen unternehmerischer Eigenverantwortung und staatlicher Steuerung

    Energy Technology Data Exchange (ETDEWEB)

    Maetzig, Karoline

    2012-07-01

    The publication provides a systematic outline of the legal boundary conditions governing the operation of electric power supply grids. It goes beyond mere regulatory aspects, covering also the projecting and construction of grids, the acquisition or leasing of land for power transmission line construction, operating licenses and utility certification, the organisational structure and purpose of electric utilities, as well as the operating, servicing and enhancement of electricity grids including calculation of electricity rates. In addition to this systematic outline of legal aspects, it is investigated how the balance between entrepreneurial responsibility and state control was defined in the EnWG 2011, and it is discussed if the law provides sufficient room for entrepreneurial decisions.

  11. Scenarios for Low Carbon and Low Water Electric Power Plant Operations: Implications for Upstream Water Use.

    Science.gov (United States)

    Dodder, Rebecca S; Barnwell, Jessica T; Yelverton, William H

    2016-11-01

    Electric sector water use, in particular for thermoelectric operations, is a critical component of the water-energy nexus. On a life cycle basis per unit of electricity generated, operational (e.g., cooling system) water use is substantially higher than water demands for the fuel cycle (e.g., natural gas and coal) and power plant manufacturing (e.g., equipment and construction). However, could shifting toward low carbon and low water electric power operations create trade-offs across the electricity life cycle? We compare business-as-usual with scenarios of carbon reductions and water constraints using the MARKet ALlocation (MARKAL) energy system model. Our scenarios show that, for water withdrawals, the trade-offs are minimal: operational water use accounts for over 95% of life cycle withdrawals. For water consumption, however, this analysis identifies potential trade-offs under some scenarios. Nationally, water use for the fuel cycle and power plant manufacturing can reach up to 26% of the total life cycle consumption. In the western United States, nonoperational consumption can even exceed operational demands. In particular, water use for biomass feedstock irrigation and manufacturing/construction of solar power facilities could increase with high deployment. As the United States moves toward lower carbon electric power operations, consideration of shifting water demands can help avoid unintended consequences.

  12. Benefits analysis of Soft Open Points for electrical distribution network operation

    International Nuclear Information System (INIS)

    Cao, Wanyu; Wu, Jianzhong; Jenkins, Nick; Wang, Chengshan; Green, Timothy

    2016-01-01

    Highlights: • An analysis framework was developed to quantify the operational benefits. • The framework considers both network reconfiguration and SOP control. • Benefits were analyzed through both quantitative and sensitivity analysis. - Abstract: Soft Open Points (SOPs) are power electronic devices installed in place of normally-open points in electrical power distribution networks. They are able to provide active power flow control, reactive power compensation and voltage regulation under normal network operating conditions, as well as fast fault isolation and supply restoration under abnormal conditions. A steady state analysis framework was developed to quantify the operational benefits of a distribution network with SOPs under normal network operating conditions. A generic power injection model was developed and used to determine the optimal SOP operation using an improved Powell’s Direct Set method. Physical limits and power losses of the SOP device (based on back to back voltage-source converters) were considered in the model. Distribution network reconfiguration algorithms, with and without SOPs, were developed and used to identify the benefits of using SOPs. Test results on a 33-bus distribution network compared the benefits of using SOPs, traditional network reconfiguration and the combination of both. The results showed that using only one SOP achieved a similar improvement in network operation compared to the case of using network reconfiguration with all branches equipped with remotely controlled switches. A combination of SOP control and network reconfiguration provided the optimal network operation.

  13. Working group on unbundling of electricity trade operations 2. A group report; Saehkoeliiketoimintojen eriyttaemistyoeryhmae 2. Tyoeryhmaen mietintoe

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-01

    The current unbundling of operations in accounts has proved inadequate. No formula or model that could be made binding by provisions have been defined for unbundled accounts. In addition, unbundling can draw a distinct line between commercial activities and network operations, which have assumed various authoritative functions. Against this background, the need for clearer unbundling has become more marked. The working group suggests that the current provisions on unbundling of trade operations should be tightened and that the unbundling should be made clearer especially in terms of allocation of joint costs. For this, the necessary preparations by the authorities should be initiated urgently. At the same time, the working group proposes that network operations should be unbundled from other operations by incorporation or by unbundling them into a separate public utility. The smallest electric utilities should be exempted from the obligation of incorporating network operations. According to the working group, the lower limit could be fixed e.g. at 70 GWh a year. The working group also suggests that the licensees must own the electricity networks they operate. The licensees could not rent their networks from the mother company nor lease them from a financing company. The model proposed by the working group would redress the major problems connected with the supervision of the electricity market. The monopoly, i.e. the electricity network operations, under the supervision of the Electricity Market Authority could thus be unbundled. This would improve the functioning of the market and facilitate the supervision. However, the model would not abolish the tax concession of municipal public utilities in competitive trade operations, production and sale of electricity. The tax concession may affect the competitive situation on the electricity market. (orig.)

  14. Electric utility deregulation - A nuclear opportunity

    International Nuclear Information System (INIS)

    DeMella, J.R.

    2002-01-01

    influenced and ultimately determined the price or tariffs for electricity to customers, were generally the same. Utilities revenue requirements were founded upon complex 'cost of service' formulas which emphasized and allowed the recovery of all 'reasonable' costs including operating expenses, taxes, depreciation of investments and additionally assured a reasonable rate or return on all outstanding investments. The consequence was that, through regulation of electric rate design, the ultimate price of electricity was determined by the aggregate of costs to produce it, independent of the forces of supply and demand. Through the examination of the major principles and features of regulated compared to unregulated electric markets such as the 'obligation to serve' and the 'cost of service', this presentation will address and discuss the economic opportunities and risks associated with nuclear power plants operating in deregulated, competitive electric generation markets. In transitioning to competitive markets, a number of key economic questions will be raised that will emphasize nuclear plant economic requirements for a profitable enterprise, addressing factors such as, plant operating performance, market conditions, energy price, key economic measures, investment opportunities, nuclear asset valuation and plant life extension. An economic analysis of a recent nuclear power plant valuation study will be presented including a discussion of key input variables, financial assumptions, economic results and a brief demonstration of an interactive, PC based computer model used for the analysis. A similar model, is currently being considered by the IAEA to evaluate the economics of nuclear power plant life extension along with alternative generation approaches. In closing, a number of short and long term prospects for the future of nuclear power will be discussed including plant life extension and the prognostication of a new electric generation business model concept

  15. An Optimal Operating Strategy for Battery Life Cycle Costs in Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Yinghua Han

    2014-01-01

    Full Text Available Impact on petroleum based vehicles on the environment, cost, and availability of fuel has led to an increased interest in electric vehicle as a means of transportation. Battery is a major component in an electric vehicle. Economic viability of these vehicles depends on the availability of cost-effective batteries. This paper presents a generalized formulation for determining the optimal operating strategy and cost optimization for battery. Assume that the deterioration of the battery is stochastic. Under the assumptions, the proposed operating strategy for battery is formulated as a nonlinear optimization problem considering reliability and failure number. And an explicit expression of the average cost rate is derived for battery lifetime. Results show that the proposed operating strategy enhances the availability and reliability at a low cost.

  16. Incentive regulation regarding the service quality of electricity and natural gas network operators in 2015. Follow-up Report, January 2017

    International Nuclear Information System (INIS)

    2017-01-01

    The tariffs set by the French Energy Regulation Commission (CRE) for natural gas distribution system operators (DSOs), natural gas transmission system operators (TSOs) as well as for the electricity distribution system operator (Enedis, former ERDF) include an incentive regulation regarding the quality of service. The CRE has defined indicators to monitor the performance of operators in several fields considered relevant to assess the quality of service. Some of these indicators, considered to have specific importance in ensuring that the market operates properly, are subject to a system of financial incentives: bonuses or penalties are given to operators depending on the attainment of objectives set by the CRE. Other indicators, which do not carry financial incentives, complete the mechanism and ensure a broader surveillance of the operators' service quality. A financial incentive may be applied to these indicators at a later date if the CRE deems it necessary. The analyses of the service quality monitoring indicators presented in this report cover the period from January 1 to December 31, 2015. A review of the service quality of DSOs, TSOs and Enedis is made according to these indicators. An annex contains all individual quality reports of Enedis, DSOs and TSOs

  17. A CALCULATION METHOD OF TRANSIENT MODES OF ELECTRIC SHIPS’ PROPELLING ELECTRIC PLANTS

    Directory of Open Access Journals (Sweden)

    V. A. Yarovenko

    2017-12-01

    Full Text Available The purpose of the work is to develop the method for calculating the transient modes of electric ships’ propelling electric plants during maneuver. This will allow us to evaluate and improve the maneuverability of vessels with electric motion. Methodology. The solution to the problems is proposed to be carried out on the basis of mathematical modeling of maneuvering modes. The duration of transient modes in an electric power plant at electric ships’ maneuvers is commensurable with the transient operation modes of the vessel itself. Therefore, the analysis of the electric power plants’ maneuvering modes should be made in unity with all the components of the ship’s propulsion complex. Results. A specified mathematical model of transient regimes of electric ship’s propulsion complex, including thermal motors, synchronous generators, electric power converters, propulsion motors, propellers, rudder, ship’s hull is developed. The model is universal. It covers the vast majority of modern and promising electric ships with a traditional type of propulsors. It allows calculating the current values of the basic mode indicators and assessing the quality indicators of maneuvering. The model is made in relative units. Dimensionless parameters of the complex are obtained. These parameters influence the main indicators of the quality of maneuvering. The adequacy of the suggested specified mathematical model and the developed computation method based on it were confirmed. To do this, the results of mathematical modeling for a real electric ship were compared with the data obtained in the course of field experiments conducted by other researchers. Originality. The mathematical description of a generator unit, as an integral part of an indivisible ship’s propulsion complex, makes it possible to calculate the dynamic operation modes of electric power sources during electric vessels’ maneuvering. There is an opportunity to design the electric ships

  18. Mission operations for unmanned nuclear electric propulsion outer planet exploration with a thermionic reactor spacecraft.

    Science.gov (United States)

    Spera, R. J.; Prickett, W. Z.; Garate, J. A.; Firth, W. L.

    1971-01-01

    Mission operations are presented for comet rendezvous and outer planet exploration NEP spacecraft employing in-core thermionic reactors for electric power generation. The selected reference missions are the Comet Halley rendezvous and a Jupiter orbiter at 5.9 planet radii, the orbit of the moon Io. The characteristics of the baseline multi-mission NEP spacecraft are presented and its performance in other outer planet missions, such as Saturn and Uranus orbiters and a Neptune flyby, are discussed. Candidate mission operations are defined from spacecraft assembly to mission completion. Pre-launch operations are identified. Shuttle launch and subsequent injection to earth escape by the Centaur D-1T are discussed, as well as power plant startup and the heliocentric mission phases. The sequence and type of operations are basically identical for all missions investigated.

  19. All-electric control of donor nuclear spin qubits in silicon

    Science.gov (United States)

    Sigillito, Anthony J.; Tyryshkin, Alexei M.; Schenkel, Thomas; Houck, Andrew A.; Lyon, Stephen A.

    2017-10-01

    The electronic and nuclear spin degrees of freedom of donor impurities in silicon form ultra-coherent two-level systems that are potentially useful for applications in quantum information and are intrinsically compatible with industrial semiconductor processing. However, because of their smaller gyromagnetic ratios, nuclear spins are more difficult to manipulate than electron spins and are often considered too slow for quantum information processing. Moreover, although alternating current magnetic fields are the most natural choice to drive spin transitions and implement quantum gates, they are difficult to confine spatially to the level of a single donor, thus requiring alternative approaches. In recent years, schemes for all-electrical control of donor spin qubits have been proposed but no experimental demonstrations have been reported yet. Here, we demonstrate a scalable all-electric method for controlling neutral 31P and 75As donor nuclear spins in silicon. Using coplanar photonic bandgap resonators, we drive Rabi oscillations on nuclear spins exclusively using electric fields by employing the donor-bound electron as a quantum transducer, much in the spirit of recent works with single-molecule magnets. The electric field confinement leads to major advantages such as low power requirements, higher qubit densities and faster gate times. Additionally, this approach makes it possible to drive nuclear spin qubits either at their resonance frequency or at its first subharmonic, thus reducing device bandwidth requirements. Double quantum transitions can be driven as well, providing easy access to the full computational manifold of our system and making it convenient to implement nuclear spin-based qudits using 75As donors.

  20. Quality-factor amplification in piezoelectric MEMS resonators applying an all-electrical feedback loop

    International Nuclear Information System (INIS)

    Manzaneque, T; Hernando-García, J; Sánchez-Rojas, J L; Ababneh, A; Schwarz, P; Seidel, H; Schmid, U

    2011-01-01

    An all-electrical velocity feedback control to enhance the quality factor of piezoelectric aluminium nitride (AlN)-based microcantilevers and microbridges was implemented. Two alternatives to obtain a velocity-proportional signal were demonstrated depending on the top electrode configuration. For a straightforward electrode design in one-port configuration (i.e. self-actuation and self-sensing), a velocity signal, proportional to the piezoelectric current, was used in the feedback loop by cancelling out the dielectric current electronically. For top electrodes allowing a two-port configuration (i.e. one for actuation and one for sensing), the piezoelectric current is directly extracted and its relationship with velocity is analysed taking the symmetry of the modal shape into account. Standard operational amplifier-based configurations for the feedback circuits were implemented on a printed circuit board. Quality factors were determined from the transient electrical response of the devices. Comparable results were obtained from the displacement spectrum applying a laser Doppler vibrometer. Quality factors as high as 2 × 10 5 , corresponding to an enhancement factor of about 200, were achieved in air for the lowest gain margin achievable before the circuit becomes unstable, making this kind of device more competitive for mass sensor applications due to enhanced spectral resolution.

  1. Minimization of Construction Costs for an All Battery-Swapping Electric-Bus Transportation System: Comparison with an All Plug-In System

    Directory of Open Access Journals (Sweden)

    Shyang-Chyuan Fang

    2017-06-01

    Full Text Available The greenhouse gases and air pollution generated by extensive energy use have exacerbated climate change. Electric-bus (e-bus transportation systems help reduce pollution and carbon emissions. This study analyzed the minimization of construction costs for an all battery-swapping public e-bus transportation system. A simulation was conducted according to existing timetables and routes. Daytime charging was incorporated during the hours of operation; the two parameters of the daytime charging scheme were the residual battery capacity and battery-charging energy during various intervals of daytime peak electricity hours. The parameters were optimized using three algorithms: particle swarm optimization (PSO, a genetic algorithm (GA, and a PSO–GA. This study observed the effects of optimization on cost changes (e.g., number of e-buses, on-board battery capacity, number of extra batteries, charging facilities, and energy consumption and compared the plug-in and battery-swapping e-bus systems. The results revealed that daytime charging can reduce the construction costs of both systems. In contrast to the other two algorithms, the PSO–GA yielded the most favorable optimization results for the charging scheme. Finally, according to the cases investigated and the parameters of this study, the construction cost of the plug-in e-bus system was shown to be lower than that of the battery-swapping e-bus system.

  2. Transit experience with hydrogen fueled hybrid electric buses

    International Nuclear Information System (INIS)

    Scott, P.B.; Mazaika, D.M.; Levin, J.; Edwards, T.

    2006-01-01

    Both AC Transit and SunLine Transit operate hybrid electric hydrogen fueled buses in their transit service. ACT presently operates three fuel cell buses in daily revenue service, and SunLine operates a fuel cell bus and a HHICE (Hybrid Hydrogen Internal Combustion Engine) bus. All these buses use similar electric drive train and electric accessories, although the detailed design differs notably between the fuel cell and the hybrid ICE buses. The fuel cell buses use a 120kW UTC fuel cell and a Van Hool Chassis, whereas the HHICE bus uses a turbocharged Ford engine which is capable of 140kW generator output in a New Flyer Chassis. The HHICE bus was the first in service, and has been subjected to both winter testing in Manitoba, Canada and summer testing in the Palm Springs, CA region. The winter testing included passenger sampling using questionnaires to ascertain passenger response. The fuel cell buses were introduced to service at the start of 2006. All five buses are in daily revenue service use. The paper will describe the buses and the experience of the transit properties in operating the buses. (author)

  3. The Liberalisation Process of the Spanish Electricity Sector

    International Nuclear Information System (INIS)

    Alonso, P. R.

    2001-01-01

    At the beginning of 1998, the 54/1997 Electricity Law entered into force, introducing a new configuration for the Spanish electricity system. Before this, the electric utilities and the Spanish Ministry of Industry and Energy signed a Protocol outlining the general structure of the future changes which would lead to the transformation of the Spanish electricity system from one based on a central purchasing agent model to one based on wholesale and retail competition. The structure of the power industry prior to the 54/1997 Electricity Law consisted of a number of vertically integrated electricity companies, most of them privately owned. One company (REE, Red Electrica de Espana) controlled by the State, was the System Operator, with the property of most of the Transmission Network. This company was created in 1984, as an attempt to improve overall efficiency in the sector by central co-ordination of all available resources and by central planning of new investments. Later, in 1987 a New Legal Framework (Marco Legal Estable) was established in order to assure financial stabilisation to the electric utilities, fixing revenues based on standard costs and setting a National tariff system. The start for the liberalisation process began with the 1994 Electricity Act (LOSEN) with the creation of the Regulatory Commission and the allowance to open access to new entrants. The Spanish electricity model finally set in 1998 seeks the introduction of competitiveness in the power sector through a few basic principles: Shorter state intervention by rationalisation of the energy policy constraints and by leaving to the market forces the system operation and planning (except for transmission planning); Separation of activities: Regulated activities (transmission and distribution) are separated form non-regulated activities (generation, trading); The design of a bulk power competitive market, including competition in generation, freedom of entry, a power pool managed by a market

  4. Integrated operation of electric vehicles and renewable generation in a smart distribution system

    International Nuclear Information System (INIS)

    Zakariazadeh, Alireza; Jadid, Shahram; Siano, Pierluigi

    2015-01-01

    Highlights: • The contribution of electric vehicles to provide the reserve capacity is analyzed. • Decentralized energy and reserve scheduling in a distribution system is presented. • The integrated operation of renewable generation and electric vehicles is proposed. - Abstract: Distribution system complexity is increasing mainly due to technological innovation, renewable Distributed Generation (DG) and responsive loads. This complexity makes difficult the monitoring, control and operation of distribution networks for Distribution System Operators (DSOs). In order to cope with this complexity, a novel method for the integrated operational planning of a distribution system is presented in this paper. The method introduces the figure of the aggregator, conceived as an intermediate agent between end-users and DSOs. In the proposed method, energy and reserve scheduling is carried out by both aggregators and DSO. Moreover, Electric Vehicles (EVs) are considered as responsive loads that can participate in ancillary service programs by providing reserve to the system. The efficiency of the proposed method is evaluated on an 84-bus distribution test system. Simulation results show that the integrated scheduling of EVs and renewable generators can mitigate the negative effects related to the uncertainty of renewable generation

  5. Operating characteristics and modeling of the LLNL 100-kV electric gun

    International Nuclear Information System (INIS)

    Osher, J.E.; Barnes, G.; Chau, H.H.; Lee, R.S.; Lee, C.; Speer, R.; Weingart, R.C.

    1989-01-01

    In the electric gun, the explosion of an electrically heated metal foil and the accompanying magnetic forces drive a thin flyer plate up a short barrel. Flyer velocities of up to 18 km/s make the gun useful for hypervelocity impact studies. The authors briefly review the technological evolution of the exploding-metal circuit elements that power the gun, describe the 100-kV electric gun designed at Lawrence Livermore National Laboratory (LLNL) in some detail, and present the general principles of electric gun operation. They compare the experimental performance of the LLNL gun with a simple model and with predictions of a magnetohydrodynamics code

  6. Operational demands as determining factor for electric bus charging infrastructure

    NARCIS (Netherlands)

    Beekman, R.; Van Den Hoed, R.

    2016-01-01

    Many cities in Europe have ambitious goals when it comes to making their public transport buses emission free. This article outlines the reasoning behind the choices made in the city of Amsterdam with regards to charging infrastructure for electric buses. Emphasising the importance of operational

  7. Operating requirements for power plants in the liberalised electricity market; Einsatzanforderungen an Kraftwerke im liberalisierten Strommarkt

    Energy Technology Data Exchange (ETDEWEB)

    Schwarzbach, G. [Vereinigte Energiewerke AG, Berlin (Germany)

    2000-07-01

    The onset of liberalisation in the German electricity market now dates back one and a half years. All processes related to this event are still in a process of rapid change. These developments have already led to a substantial drop in electricity prices, especially for large customers, leaving suppliers with modest margins. Power supply companies such as VEAG, whose operations in East Germany include power transmission, electricity production from brown coal and wholesale trade, are taking measures to meet the new demands placed on them. Unbundling regulations and market processes are forcing companies to review their organisational and operational structures. Risk management, controlling and DP support for processes are indispensable. Profit centre structures and internal performance accounting systems are being used to distribute the market pressure evenly across the company's divisions. Companies' future success will be determined by their success in trading and selling. These developments will also have an impact on power plants, i.e. on the first stage of the supply chain. For one thing, the costs of power plant operation have to be reduced significantly. Reductions in staff costs will necessitate a review of technological processes. Furthermore, maintenance strategies and availability goals have to be reassessed. Another crucial factor is to be seen in power plants' operational flexibility, and this will also have an impact on fuel supply contracts. A particular concern of single-plant companies and small generation systems will be how to deal with strong fluctuations in demand and meet the hourly supply schedules agreed on with the customer without having to resort to the expensive regulating services of the grid operators. Electricity produced in excess of demand will find not always find buyers, not even after the establishment of physical electricity exchanges. Another factor which will increase the volatility of required power generation

  8. Electric vehicle test report Cutler-Hammer Corvette

    Science.gov (United States)

    1981-01-01

    Vehicles were characterized for the state of the art assessment of electric vehicles. The vehicle evaluated was a Chevrolet Corvette converted to electric operation. The original internal combustion engine was replaced by an electric traction motor. Eighteen batteries supplied the electrical energy. A controller, an onboard battery charger, and several dashboard instruments completed the conversion. The emphasis was on the electrical portion of the drive train, although some analysis and discussion of the mechanical elements are included. Tests were conducted both on the road (actually a mile long runway) and in a chassis dynamometer equipped laboratory. The majority of the tests performed were according to SAE Procedure J227a and included maximum effort accelerations, constant speed range, and cyclic range. Some tests that are not a part of the SAE Procedure J227a are described and the analysis of the data from all tests is discussed.

  9. Electrolyte for a lithium/thionyl chloride electric cell, a method of preparing said electrolyte and an electric cell which includes said electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Gabano, J.

    1983-03-01

    An electrolyte for an electric cell whose negative active material is constituted by lithium and whose positive active material is constituted by thionyl chloride. The electrolyte contains at least one solvent and at least one solute, said solvent being thionyl chloride and said solute being chosen from the group which includes lithium tetrachloroaluminate and lithium hexachloroantimonate. According to the invention said electrolyte further includes a complex chosen from the group which includes AlCl/sub 3/,SO/sub 2/ and SbCl/sub 5/,SO/sub 2/. The voltage rise of electric cells which include such an electrolyte takes negligible time.

  10. The energy management manual for arena and rink operators

    Energy Technology Data Exchange (ETDEWEB)

    Raymer, M. [Saskatchewan Parks and Recreation Assoc., Regina, SK (Canada); White, T. [Office of Energy Conservation, Regina, SK (Canada); Kozoriz, D.F. [SaskPower, Regina, SK (Canada); Norman, D. [SaskPower, Saskatoon, SK (Canada)

    2006-08-15

    In an era when energy costs often rise faster than the community tax base, energy conservation plays a key role in ensuring that skating arenas are able to continue operating. This manual on energy management for arena and rink operators includes current technologies and practices that reduce operating costs. It is meant to help in the training and education of all facility operators. Since fossil fuels are the main source of electrical generation in Saskatchewan, reducing energy consumption directly reduces greenhouse gas emissions to the environment. This manual included a brief introduction to energy calculations for operators of rinks and arenas. The calculations can be performed for the heat loss that occurs in winter and the amount of heat input needed to maintain temperatures. It was recommended that the more difficult calculation of estimating the amount of cooling required for ice making should be done by qualified consultants. The 10 sections of the manual addressed the issues of: (1) electrical and natural gas rates, (2) meters and electrical inventory, (3) making a financial analysis, (4) the building envelope, (5) heating and ventilation, (6) refrigeration, (7) lighting, (8) heating effects of electrical equipment, (9) operation and maintenance, and, (10) project planning. The manual also presented methods to improve the power factor by adding relatively inexpensive components, such as capacitors, to lower electricity bills by as much as 20 per cent. A review of geo-exchange systems for rinks and arenas was included along with heat recovery from refrigeration systems and financial assistance for commercial, institutional and municipal buildings. refs., tabs., figs.

  11. The electric motor handbook

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, R.W.; Feltham, P. (eds.)

    2004-05-01

    This handbook outlines the important role that electric motors play in modern society. It covers the field of motor applications from various motor types to their use and repair. It also presents practical applications of electric motors and methods on motor efficiency. More than half of all electricity generated, and 75 per cent of all industrial electricity consumption is consumed by electric motors. Electrical personnel must be aware of all factors involved in electric motors in order to choose and apply the appropriate size of electric motor. These factors include efficiency, sizing and proper application. The efficient use and maximum life expectancy of electric motors depends on proper motor protection, control and maintenance. This handbook includes articles from leading experts on electric motors in modern electrical systems. The content includes: design considerations; proper electric motor sizing techniques; optimal electric motor application; electric motor protection technology; electric motor control principles; electric motor maintenance and troubleshooting; induction electric motors; electric motor bearing currents; electric motor bearing lubrication; electromagnetism; electric motor enclosures; electric motor testing; electric motor repair; DC electric motor; electric motor starters; electric motor brushes; industrial electric motors; electric motor diagrams; AC electric motors; electric motor wiring; electric motor service; electric motor rewinding; electric motor winding; diagram of electric motor wiring; electric motor kit; and, troubleshooting electric motors. A directory of motor manufacturers and suppliers was also included. refs., tabs., figs.

  12. 40 CFR 86.1770-99 - All-Electric Range Test requirements.

    Science.gov (United States)

    2010-07-01

    ... All-Electric Range Test. (4) Regenerative braking. Regenerative braking systems may be utilized during...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Provisions for the Voluntary National Low Emission Vehicle Program for Light-Duty...

  13. Electricity markets theories and applications

    CERN Document Server

    Lin, Jeremy

    2017-01-01

    Electricity Markets: Theories and Applications offers students and practitioners a clear understanding of the fundamental concepts of the economic theories, particularly microeconomic theories, as well as information on some advanced optimization methods of electricity markets. The authors--noted experts in the field--cover the basic drivers for the transformation of the electricity industry in both the United States and around the world and discuss the fundamentals of power system operation, electricity market design and structures, and electricity market operations. The text also explores advanced topics of power system operations and electricity market design and structure including zonal versus nodal pricing, market performance and market power issues, transmission pricing, and the emerging problems electricity markets face in smart grid and micro-grid environments. The authors also examine system planning under the context of electricity market regime. They explain the new ways to solve problems with t...

  14. Renewable Electricity Futures: Exploration of a U.S. Grid with 80% Renewable Electricity

    Science.gov (United States)

    Mai, Trieu

    2013-04-01

    Renewable Electricity Futures is an initial investigation of the extent to which renewable energy supply can meet the electricity demands of the contiguous United States over the next several decades. This study explores the implications and challenges of very high renewable electricity generation levels: from 30% up to 90% (focusing on 80%) of all U.S. electricity generation from renewable technologies in 2050. At such high levels of renewable electricity penetration, the unique characteristics of some renewable resources, specifically geographical distribution and variability and un-certainty in output, pose challenges to the operability of the nation's electric system. The study focuses on key technical implications of this environment from a national perspective, exploring whether the U.S. power system can supply electricity to meet customer demand on an hourly basis with high levels of renewable electricity, including variable wind and solar generation. The study also identifies some of the potential economic, environmental, and social implications of deploying and integrating high levels of renewable electricity in the U.S. The full report and associated supporting information is available at: http://www.nrel.gov/analysis/refutures/.

  15. Mutual influences of reactor operation and fuel cycle management

    International Nuclear Information System (INIS)

    Lewiner, C.; Schaerer, R.

    1989-01-01

    OPEN (Organisation des Producteurs d'Energie Nucleaire) comprises the electricity producers from seven European countries which now operate or intend to operate nuclear power plants. Its activities include the study of technical, economic and legal subjects related to nuclear electricity. A continuous analysis of the fuel cycle market has been pursued within OPEN for almost 15 years. For the past few years, OPEN has also been concerned with the subject of fuel management in the reactors operated by its members. The purpose of this effort was to obtain an overall picture of possible fuel improvements and to evaluate the effects, in particular the economic ones, of diverse fuel reload managements and of reprocessed uranium and plutonium recycling. The conclusions of this study are as follows: Increase in burn-ups produces notable savings in electricity generating costs. It also permits adaptation of fuel loading mode to the desirable irradiation campaign length. This allows for better management of the country's overall means of electricity generation (nuclear, fossil-fuelled or hydro plants), and adjustment to the electrical demand. These new reload schemes have various impacts on natural uranium consumption and enrichment, but, above all, they affect directly all fuel cycle operations linked to the number of assemblies (fabrication, reprocessing, etc.). 6 figs

  16. Direct-phase-variable model of a synchronous reluctance motor including all slot and winding harmonics

    International Nuclear Information System (INIS)

    Obe, Emeka S.; Binder, A.

    2011-01-01

    A detailed model in direct-phase variables of a synchronous reluctance motor operating at mains voltage and frequency is presented. The model includes the stator and rotor slot openings, the actual winding layout and the reluctance rotor geometry. Hence, all mmf and permeance harmonics are taken into account. It is seen that non-negligible harmonics introduced by slots are present in the inductances computed by the winding function procedure. These harmonics are usually ignored in d-q models. The machine performance is simulated in the stator reference frame to depict the difference between this new direct-phase model including all harmonics and the conventional rotor reference frame d-q model. Saturation is included by using a polynomial fitting the variation of d-axis inductance with stator current obtained by finite-element software FEMAG DC (registered) . The detailed phase-variable model can yield torque pulsations comparable to those obtained from finite elements while the d-q model cannot.

  17. Operational experience in the non-destructive assay of fissile material in General Electric's nuclear fuel fabrication facility

    International Nuclear Information System (INIS)

    Stewart, J.P.

    1976-01-01

    Operational experience in the non-destructive assay of fissile material in a variety of forms and containers and incorporation of the assay devices into the accountability measurement system for General Electric's Wilmington Fuel Fabrication Facility measurement control programme is detailed. Description of the purpose and related operational requirements of each non-destructive assay system is also included. In addition, the accountability data acquisition and processing system is described in relation to its interaction with the various non-destructive assay devices and scales used for accountability purposes within the facility. (author)

  18. Electric rate operations

    International Nuclear Information System (INIS)

    Maillard, D.

    1993-01-01

    The share of nuclear power in EDF production implies multiple rate structures. How are these rates determined. What are the new applications of electricity, and in particular those that make use of the especially low summer prices for electricity. These are topics of interest to the man in the street (witness EDF's recent 'red-white-blue' rates). This prompted the 'Nuclear Power in the Financial, Energy and Economic situation' department of France's nuclear power company to organize a conference bringing together an expert on rates - M.P. Bernard, head of the rate fixing service at the EDF's headquarters - and representatives from suppliers of equipment taking advantage of the various EDF rate options

  19. Guidelines for Distribution System Operators on Reactive Power Provision by Electric Vehicles in Low Voltage Grids

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia; Træholt, Chresten

    2017-01-01

    The increasing success of electric vehicles is bringing new technical challenges to power system operators. This work intends to provide guidelines for distribution system operators in terms of reactive power requirements when evaluating and authorizing electric vehicles supply equipment with fast...... the amount of reactive power that an individual electric vehicle is expected to provide when connected to a low voltage feeder, in order to benefit of the desired voltage rise effect in comparison to the case of unitary power factor....

  20. Heat operated cryogenic electrical generator

    International Nuclear Information System (INIS)

    Fletcher, J.C.; Wang, T.C.; Saffren, M.M.; Elleman, D.D.

    1975-01-01

    An electrical generator useful for providing electrical power in deep space, is disclosed. The subject electrical generator utilizes the unusual hydrodynamic property exhibited by liquid helium as it is converted to and from a superfluid state to cause opposite directions of rotary motion for a rotor cell thereof. The physical motion of said rotor cell is employed to move a magnetic field provided by a charged superconductive coil mounted on the exterior of said cell. An electrical conductor is placed in surrounding proximity to said cell to interact with the moving magnetic field provided by the superconductive coil and thereby generate electrical energy. A heat control arrangement is provided for the purpose of causing the liquid helium to be partially converted to and from a superfluid state by being cooled and heated, respectively. (U.S.)

  1. New remuneration models for electricity supply from autoproducers: Cost-orientated, including capacity charge, on a private-enterprise basis

    International Nuclear Information System (INIS)

    Zybell, G.

    1995-01-01

    Co-operation between industrial autoproducers and the public utilities has a long tradition in Germany. This is particularly the case in combined heat and power generation. In 1993 electricity supplied by third parties contributed with approximately 14% to electricity demand coverage. This is (as in Italy) the next highest proportion in the EU. In 1994 the industry's associations -BDI, VIK and VDEW - agreed upon new remuneration models for electricity supplied by combined heat and power stations and plants on the basis of renewable energies. Additionally, principles agreed upon in 1979 were further developed. (orig.) [de

  2. Method for protecting an electric generator

    Science.gov (United States)

    Kuehnle, Barry W.; Roberts, Jeffrey B.; Folkers, Ralph W.

    2008-11-18

    A method for protecting an electrical generator which includes providing an electrical generator which is normally synchronously operated with an electrical power grid; providing a synchronizing signal from the electrical generator; establishing a reference signal; and electrically isolating the electrical generator from the electrical power grid if the synchronizing signal is not in phase with the reference signal.

  3. 78 FR 44900 - Communication of Operational Information Between Natural Gas Pipelines and Electric Transmission...

    Science.gov (United States)

    2013-07-25

    ... Regional Transmission Organizations and Independent System Operators (RTOs/ISOs) also noted that, although... operator from discussions between RTOs/ ISOs and natural gas pipelines regarding the status of a generator... not customers of electric transmission operators. Likewise, in the case of RTOs/ISOs, they are not...

  4. Experience in operation and maintenance of systems of electrical generation by micro turbine: Transierra S.A.

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, Franz Miranda [TRANSIERRA S.A., Santa Cruz (Bolivia)

    2009-07-01

    This work tries to share the experience of throughout six years, turned into experience of operation and maintenance of micro turbines for generation electrical; same those are used in the stations of measurement of Transierra S.A. In the initial stage it would describe to the ways and characteristic operative qualities for each one of the Micro Turbines in each scene that differs throughout the four stations that the GASYRG composes, taking like game the analysis of the thermal efficiency. Next a particular description of happened events would be realized in the six translated years in faults of general and particular way, centering the attention to the analysis of the resources provided by the controllers of the equipment through registry of events. Analyses that finally would be translated in solutions to short and medium term obtaining operative continuity and provision of electrical energy indispensable for the systems of measurement and control of the stations. Finally a description of all the particular solutions and modifications that went giving problems of design which they were not contemplated by the manufacturer emanated of the necessity and shaped with the aid of the same knowledge of the equipment. (author)

  5. Nuclear Electric's central dose record service

    International Nuclear Information System (INIS)

    Goldfinch, E.P.; Mullarkey, D.T.; McWhan, A.W.; Risk, G.; Vaughan, L.

    1991-01-01

    This paper describes the conception, development and operation of the Nuclear Electric Central Dose Record Service, including the initial philosophy considered necessary for a database for a large multi-site organisation, the setting up of the data and current routine operation. Lessons learned are briefly described. CDRS holds 35,000 records in a high security environment. The database includes records of radiation doses received by contractor's employees working at Nuclear Electric sites as well as dose records and dose histories for classified and non classified Nuclear Electric employees. (Author)

  6. Conceptual Design of Operation Strategies for Hybrid Electric Aircraft

    Directory of Open Access Journals (Sweden)

    Julian Hoelzen

    2018-01-01

    Full Text Available Ambitious targets to reduce emissions caused by aviation in the light of an expected ongoing rise of the air transport demand in the future drive the research of propulsion systems with lower CO2 emissions. Regional hybrid electric aircraft (HEA powered by conventional gas turbines and battery powered electric motors are investigated to test hybrid propulsion operation strategies. Especially the role of the battery within environmentally friendly concepts with significantly reduced carbon footprint is analyzed. Thus, a new simulation approach for HEA is introduced. The main findings underline the importance of choosing the right power-to-energy-ratio of a battery according to the flight mission. The gravimetric energy and power density of the electric storages determine the technologically feasibility of hybrid concepts. Cost competitive HEA configurations are found, but do not promise the targeted CO2 emission savings, when the well-to-wheel system is regarded with its actual costs. Sensitivity studies are used to determine external levers that favor the profitability of HEA.

  7. Development of an electrically operated cassava slicing machine

    Directory of Open Access Journals (Sweden)

    I. S. Aji

    2013-08-01

    Full Text Available Labor input in manual cassava chips processing is very high and product quality is low. This paper presents the design and construction of an electrically operated cassava slicing machine that requires only one person to operate. Efficiency, portability, ease of operation, corrosion prevention of slicing component of the machine, force required to slice a cassava tuber, capacity of 10 kg/min and uniformity in the size of the cassava chips were considered in the design and fabrication of the machine. The performance of the machine was evaluated with cassava of average length and diameter of 253 mm and 60 mm respectively at an average speed of 154 rpm. The machine produced 5.3 kg of chips of 10 mm length and 60 mm diameter in 1 minute. The efficiency of the machine was 95.6% with respect to the quantity of the input cassava. The chips were found to be well chipped to the designed thickness, shape and of generally similar size. Galvanized steel sheets were used in the cutting section to avoid corrosion of components. The machine is portable and easy to operate which can be adopted for cassava processing in a medium size industry.

  8. Optimal operation strategies of compressed air energy storage (CAES) on electricity spot markets with fluctuating prices

    DEFF Research Database (Denmark)

    Lund, Henrik; Salgi, Georges; Elmegaard, Brian

    2009-01-01

    on electricity spot markets by storing energy when electricity prices are low and producing electricity when prices are high. In order to make a profit on such markets, CAES plant operators have to identify proper strategies to decide when to sell and when to buy electricity. This paper describes three...... plants will not be able to achieve such optimal operation, since the fluctuations of spot market prices in the coming hours and days are not known. Consequently, two simple practical strategies have been identified and compared to the results of the optimal strategy. This comparison shows that...... independent computer-based methodologies which may be used for identifying the optimal operation strategy for a given CAES plant, on a given spot market and in a given year. The optimal strategy is identified as the one which provides the best business-economic net earnings for the plant. In practice, CAES...

  9. Electric Power Monthly, June 1988

    International Nuclear Information System (INIS)

    1988-06-01

    The data in this report are presented for a wide audience including Congress, Federal and State agencies, the electric utility industry, and the general public. The Energy Information Administration (EIA) collected the information in this report to fulfill its data collection and dissemination responsibilities as specified in the Federal Energy Administration Act of 1974 (Public Law 93-275) as amended. The Electric Power Monthly contains information from three data sources: the Form EIA-759, 'Monthly Power Plant Report'; the Federal Energy Regulatory Commission (FERC) Form 423, 'Monthly Report of Cost and Quality of Fuels for Electric Plants ; and the Form EIA-826, M onthly Electric Sales and Revenue Report with State Distributions'. The Form EIA-759 collects data from all operators of electric utility generating plants (except those having plants solely on standby), approximately 800 of the more than 3,200 electric utilities in the United States. To reduce the reporting burden for utilities, the FERC Form 423 and Form EIA-826 data are based on samples, which cover less than 100 percent of all central station generating utilities. The FERC Form 423 collects data from steam-electric power generating plants with a combined installed nameplate capacity of 50 megawatts or larger (approximately 230 electric utilities). The 50-megawatt threshold was established by FERC. The Form EIA-826 collects sales and revenue data in the residential, commercial, industrial, and other sectors of the economy. Other sales data collected include public street and highway lighting, other sales to public authorities, sales to railroads and railways, and interdepartmental sales. Respondents to the Form EIA-826 were statistically chosen and include approximately 225 privately and publicly owned electric utilities from a universe of more than 3,200 utilities. The sample selection for the Form EIA-826 is evaluated annually. Currently, the Form EIA-826 data account for approximately 83 percent

  10. Advanced launch system (ALS) - Electrical actuation and power systems improve operability and cost picture

    Science.gov (United States)

    Sundberg, Gale R.

    1990-01-01

    To obtain the Advanced Launch System (ALS) primary goals of reduced costs and improved operability, there must be significant reductions in the launch operations and servicing requirements relative to current vehicle designs and practices. One of the primary methods for achieving these goals is by using vehicle electrrical power system and controls for all aviation and avionics requirements. A brief status review of the ALS and its associated Advanced Development Program is presented to demonstrate maturation of those technologies that will help meet the overall operability and cost goals. The electric power and actuation systems are highlighted as a sdpecific technology ready not only to meet the stringent ALS goals (cryogenic field valves and thrust vector controls with peak power demands to 75 hp), but also those of other launch vehicles, military ans civilian aircraft, lunar/Martian vehicles, and a multitude of comercial applications.

  11. Manifestations of geometric phases in a proton electric-dipole-moment experiment in an all-electric storage ring

    Science.gov (United States)

    Silenko, Alexander J.

    2017-12-01

    We consider a proton electric-dipole-moment experiment in an all-electric storage ring when the spin is frozen and local longitudinal and vertical electric fields alternate. In this experiment, the geometric (Berry) phases are very important. Due to the these phases, the spin rotates about the radial axis. The corresponding systematic error is rather important while it can be canceled with clockwise and counterclockwise beams. The geometric phases also lead to the spin rotation about the radial axis. This effect can be canceled with clockwise and counterclockwise beams as well. The sign of the azimuthal component of the angular velocity of the spin precession depends on the starting point where the spin orientation is perfect. The radial component of this quantity keeps its value and sign for each starting point. When the longitudinal and vertical electric fields are joined in the same sections without any alternation, the systematic error due to the geometric phases does not appear but another systematic effect of the spin rotation about the azimuthal axis takes place. It has opposite signs for clockwise and counterclockwise beams.

  12. Operational synergy in the US electric utility industry under an influence of deregulation policy: A linkage to financial performance and corporate value

    International Nuclear Information System (INIS)

    Sueyoshi, Toshiyuki; Goto, Mika

    2011-01-01

    have examined a synergy effect between electricity and gas services in the US electric utility industry. They have compared electricity-specialized firms with diversified utility firms in their financial performance and corporate value. A problem of their study is that it has not empirically measured the operational performance of the electric utility firms. As an extension of the preceding study, this research investigates the operational performance of 104 US electric utility firms (1990-2004) by fully utilizing DEA (Data Envelopment Analysis). This study finds the three new policy implications. First, the synergy effect has not existed in the operational performance of diversified utility firms before and after the deregulation on the US electricity markets. Thus, core business concentration is more effective for electric utility firms than corporate diversification to enhance their operational performance under the current US deregulation policy. Second, the operational performance has had an increasing trend until 1996 and a decreasing trend after 1996. Thus, the US deregulation policy has been influential on their operational performance. Third, the enhancement in operational performance of electric utility firms has improved their financial performance. The improvement in financial performance has increased their corporate value. Thus, this study finds the business causality among operational performance, financial performance and corporate value in the US electric utility industry. - Research Highlights: →The synergy effect has not existed in the operational performance of diversified utility firms before and after the deregulation on the US electricity markets. →Core business concentration is more effective for electric utility firms than corporate diversification to enhance their operational performance under the current US deregulation policy. →The operational performance has had an increasing trend until 1996 and a decreasing trend after 1996.

  13. 75 FR 49528 - Thomson Reuters Legal, Legal Editorial Operations Cleveland Office Including Workers Whose...

    Science.gov (United States)

    2010-08-13

    ... Philippines and India. The amended notice applicable to TA-W-73,370 is hereby issued as follows: ``All workers..., Legal Editorial Operations Cleveland Office Including Workers Whose Unemployment Insurance (UI) Wages... Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordance with Section 223 of...

  14. W-087 Operational test report. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, A.W.

    1997-06-10

    This Acceptance Test Procedure/Operational Test Procedure (ATP/OTP) has been prepared to demonstrate that the Electrical/Instrumentation and Mechanical systems function as required by project criteria and to verify proper operation of the integrated system including the interlocks. The equipment to be tested includes the following: a. Leak detection system operation and controls. b. Electrical interlocks.- C. Transfer pump oper ation. d. Vacuum breaker system interlocks.

  15. Optimal Operation of the Integrated Electrical and Heating Systems to Accommodate the Intermittent Renewable Sources

    DEFF Research Database (Denmark)

    Li, Jinghua; Fang, Jiakun; Zeng, Qing

    2016-01-01

    The integration of electrical and heating systems has great potential to enhance the flexibility of power systems to accommodate more renewable power such as the wind and solar. This study was to investigate an optimal way to integrate the energy of both systems in urban areas. The amount of energy...... the effectiveness of the proposed solution. The results showed that coordinated optimization of the energy distribution have significant benefits for reducing wind curtailment, operation cost, and energy losses. The proposed model and methodology could help system operators with decision support in the emerging...... conversion between the electrical system and heating system was optimally decided so that the demand within both systems could be met at the least operational cost. Besides, the best node to join with the electrical system and heating system was chosen by consideration of the energy transmission loss...

  16. DOE Fundamentals Handbook: Electrical Science, Volume 1

    International Nuclear Information System (INIS)

    1992-06-01

    The Electrical Science Fundamentals Handbook was developed to assist nuclear facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of electrical theory, terminology, and application. The handbook includes information on alternating current (AC) and direct current (DC) theory, circuits, motors, and generators; AC power and reactive components; batteries; AC and DC voltage regulators; transformers; and electrical test instruments and measuring devices. This information will provide personnel with a foundation for understanding the basic operation of various types of DOE nuclear facility electrical equipment

  17. DOE Fundamentals Handbook: Electrical Science, Volume 3

    International Nuclear Information System (INIS)

    1992-06-01

    The Electrical Science Fundamentals Handbook was developed to assist nuclear facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of electrical theory, terminology, and application. The handbook includes information on alternating current (AC) and direct current (DC) theory, circuits, motors and generators; AC power and reactive components; batteries; AC and DC voltage regulators; transformers; and electrical test instruments and measuring devices. This information will provide personnel with a foundation for understanding the basic operation of various types of DOE nuclear facility electrical equipment

  18. DOE Fundamentals Handbook: Electrical Science, Volume 4

    International Nuclear Information System (INIS)

    1992-06-01

    The Electrical Science Fundamentals Handbook was developed to assist nuclear facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of electrical theory, terminology, and application. The handbook includes information on alternating current (AC) and direct current (DC) theory, circuits, motors, and generators; AC power and reactive transformers; and electrical test components; batteries; AC and DC voltage regulators; instruments and measuring devices. This information will provide personnel with a foundation for understanding the basic operation of various types of DOE nuclear facility electrical equipment

  19. Managing operations of plug-in hybrid electric vehicle (PHEV) exchange stations for use with a smart grid

    International Nuclear Information System (INIS)

    Nurre, Sarah G.; Bent, Russell; Pan, Feng; Sharkey, Thomas C.

    2014-01-01

    We consider a deterministic integer programming model for determining the optimal operations of multiple plug-in hybrid electric vehicle (PHEV) battery exchange stations over time. The operations include the number of batteries to charge, discharge, and exchange at each point in time over a set time horizon. We allow discharging of batteries back to the power grid, through vehicle-to-grid technology. We incorporate the exchange station's dependence on the power network, transportation network, and other exchange stations. The charging and discharging at these exchange stations lead to a greater amount of variability which creates a less predictable and flat power generation curve. We introduce and test three policies to smooth the power generation curve by balancing its load. Further, tests are conducted evaluating these policies while factoring wind energy into the power generation curve. These computational tests use realistic data and analysis of the results suggest general operating procedures for exchange stations and evaluate the effectiveness of these power flattening policies. - Highlights: • Model the operations of plug-in hybrid electric vehicle battery exchange stations. • Determine the optimal and general charging, discharging, and exchange operations. • Conclude that forced customer service levels are unnecessary with proper pricing. • Examine policies to reduce variability in power generation from PHEVs and wind. • Observe that strict constraints on exchange stations best reduce variability

  20. 75 FR 47632 - Thomson Reuters Legal, Legal Editorial Operations, Cleveland Office, Including Workers Whose...

    Science.gov (United States)

    2010-08-06

    ... Philippines and India. The amended notice applicable to TA-W-73,370 is hereby issued as follows: All workers..., Legal Editorial Operations, Cleveland Office, Including Workers Whose Unemployment Insurance (UI) Wages... To Apply for Worker Adjustment Assistance In accordance with Section 223 of the Trade Act of 1974, as...

  1. Human factors review of electric power dispatch control centers. Volume 3. Operator information needs summary. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R.J.; Najaf-Zadeh, K.; Darlington, H.T.; McNair, H.D.; Seidenstein, S.; Williams, A.R.

    1982-10-01

    Human factors is a systems-oriented interdisciplinary specialty concerned with the design of systems, equipment, facilities and the operational environment. An important aspect leading to the design requirements is the determination of the information requirements for electric power dispatch control centers. There are significant differences between the system operator's actions during normal and degraded states of power system operation, and power system restoration. This project evaluated the information the operator requires for normal power system and control system operations and investigates the changes of information required by the operator as the power system and/or the control system degrades from a normal operating state. The Phase II study, published in two volumes, defines power system states and control system conditions to which operator information content can be related. This volume presents a summary of operator information needs, identifying the needs for and the uses of power system information by a system operator in conditions ranging from normal through degraded operation. Training requirements are also included for planning entry-level and follow-on training for operators.

  2. A reduced-form approach for representing the impacts of wind and solar PV deployment on the structure and operation of the electricity system

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Nils; Strubegger, Manfred; McPherson, Madeleine; Parkinson, Simon C.; Krey, Volker; Sullivan, Patrick

    2017-05-01

    In many climate change mitigation scenarios, integrated assessment models of the energy and climate systems rely heavily on renewable energy technologies with variable and uncertain generation, such as wind and solar PV, to achieve substantial decarbonization of the electricity sector. However, these models often include very little temporal resolution and thus have difficulty in representing the integration costs that arise from mismatches between electricity supply and demand. The global integrated assessment model, MESSAGE, has been updated to explicitly model the trade-offs between variable renewable energy (VRE) deployment and its impacts on the electricity system, including the implications for electricity curtailment, backup capacity, and system flexibility. These impacts have been parameterized using a reduced-form approach, which allows VRE integration impacts to be quantified on a regional basis. In addition, thermoelectric technologies were updated to include two modes of operation, baseload and flexible, to better account for the cost, efficiency, and availability penalties associated with flexible operation. In this paper, the modeling approach used in MESSAGE is explained and the implications for VRE deployment in mitigation scenarios are assessed. Three important stylized facts associated with integrating high VRE shares are successfully reproduced by our modeling approach: (1) the significant reduction in the utilization of non-VRE power plants; (2) the diminishing role for traditional baseload generators, such as nuclear and coal, and the transition to more flexible technologies; and (3) the importance of electricity storage and hydrogen electrolysis in facilitating the deployment of VRE.

  3. 76 FR 23222 - Electric Reliability Organization Interpretation of Transmission Operations Reliability

    Science.gov (United States)

    2011-04-26

    ....3d 1342 (DC Cir. 2009). \\5\\ Mandatory Reliability Standards for the Bulk-Power System, Order No. 693... Reliability Standards for the Bulk-Power System. Action: FERC-725A. OMB Control No.: 1902-0244. Respondents...] Electric Reliability Organization Interpretation of Transmission Operations Reliability AGENCY: Federal...

  4. Economic impact assessment and operational decision making in emission and transmission constrained electricity markets

    International Nuclear Information System (INIS)

    Nanduri, Vishnu; Kazemzadeh, Narges

    2012-01-01

    Highlights: ► We develop a bilevel game-theoretic model for allowance and electricity markets. ► We solve the model using a reinforcement learning algorithm. ► Model accounts for transmission constraints, cap-and-trade constraints. ► Study demonstrated on 9-bus electric power network. ► Obtain insights about supply shares, impact of transmission constraints, and cost pass through. -- Abstract: Carbon constrained electricity markets are a reality in 10 northeastern states and California in the US, as well as the European Union. Close to a Billion US Dollars have been spent by entities (mainly generators) in the Regional Greenhouse Gas Initiative in procuring CO 2 allowances to meet binding emissions restrictions. In the near future, there are expected to be significant impacts due to the cap-and-trade program, especially when the cap stringency increases. In this research we develop a bilevel, complete-information, matrix game-theoretic model to assess the economic impact and make operational decisions in carbon-constrained restructured electricity markets. Our model is solved using a reinforcement learning approach, which takes into account the learning and adaptive nature of market participants. Our model also accounts for all the power systems constraints via a DC-OPF problem. We demonstrate the working of the model and compute various economic impact indicators such as supply shares, cost pass-through, social welfare, profits, allowance prices, and electricity prices. Results from a 9-bus power network are presented.

  5. Systems Analysis Initiated for All-Electric Aircraft Propulsion

    Science.gov (United States)

    Kohout, Lisa L.

    2003-01-01

    A multidisciplinary effort is underway at the NASA Glenn Research Center to develop concepts for revolutionary, nontraditional fuel cell power and propulsion systems for aircraft applications. There is a growing interest in the use of fuel cells as a power source for electric propulsion as well as an auxiliary power unit to substantially reduce or eliminate environmentally harmful emissions. A systems analysis effort was initiated to assess potential concepts in an effort to identify those configurations with the highest payoff potential. Among the technologies under consideration are advanced proton exchange membrane (PEM) and solid oxide fuel cells, alternative fuels and fuel processing, and fuel storage. Prior to this effort, the majority of fuel cell analysis done at Glenn was done for space applications. Because of this, a new suite of models was developed. These models include the hydrogen-air PEM fuel cell; internal reforming solid oxide fuel cell; balance-of-plant components (compressor, humidifier, separator, and heat exchangers); compressed gas, cryogenic, and liquid fuel storage tanks; and gas turbine/generator models for hybrid system applications. Initial mass, volume, and performance estimates of a variety of PEM systems operating on hydrogen and reformate have been completed for a baseline general aviation aircraft. Solid oxide/turbine hybrid systems are being analyzed. In conjunction with the analysis efforts, a joint effort has been initiated with Glenn s Computer Services Division to integrate fuel cell stack and component models with the visualization environment that supports the GRUVE lab, Glenn s virtual reality facility. The objective of this work is to provide an environment to assist engineers in the integration of fuel cell propulsion systems into aircraft and provide a better understanding of the interaction between system components and the resulting effect on the overall design and performance of the aircraft. Initially, three

  6. Reconfiguration strategies for electrical devices for operation within feasibility margins

    Energy Technology Data Exchange (ETDEWEB)

    Gandor, Malin; Blank, Marita [Oldenburg Univ. (Germany); Lehnhoff, Sebastian [OFFIS - Institut fuer Informatik, Oldenburg (Germany)

    2012-07-01

    Due to a transition of the energy system towards a sustainable energy supply by the integration of renewable, decentralized energy resources, new challenges regarding a safe and secure energy supply appear. With renewable energy resources the power fee-in will be highly volatile. Furthermore, due to a correlated feed-in depending on e.g. weather phenomena or control strategies on the demand side, the system might be operated beyond feasible boundaries. However, the satisfaction of viable operational boundaries must be guaranteed. In this paper a method is presented that allows the utilization of degrees of freedom in form of decentralized flexible electric consumers and products in order to optimize an operational state with regard to its feasibility. First results are presented in a case study. (orig.)

  7. 76 FR 77815 - Ethical Electric Benefit Co.; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2011-12-14

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER12-543-000] Ethical Electric Benefit Co.; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for... Ethical Electric Benefit Co.'s application for market-based rate authority, with an accompanying rate...

  8. Historical plant cost and annual production expenses for selected electric plants, 1982

    International Nuclear Information System (INIS)

    1984-01-01

    This publication is a composite of the two prior publications, Hydroelectric Plant Construction Cost and Annual Production Expenses and Thermal-Electric Plant Construction Cost and Annual Production Expenses. Beginning in 1979, Thermal-Electric Plant Construction Cost and Annual Production Expenses contained information on both steam-electric and gas-turbine electric plant construction cost and annual production expenses. The summarized historical plant cost described under Historical Plant Cost in this report is the net cumulative-to-date actual outlays or expenditures for land, structures, and equipment to the utility. Historical plant cost is the initial investment in plant (cumulative to the date of initial commercial operation) plus the costs of all additions to the plant, less the value of retirements. Thus, historical plant cost includes expenditures made over several years, as modifications are made to the plant. Power Production Expenses is the reporting year's plant operation and maintenance expenses, including fuel expenses. These expenses do not include annual fixed charges on plant cost (capital costs) such as interest on debt, depreciation or amortization expenses, and taxes. Consequently, total production expenses and the derived unit costs are not the total cost of producing electric power at the various plants. This publication contains data on installed generating capacity, net generation, net capability, historical plant cost, production expenses, fuel consumption, physical and operating plant characteristics, and other relevant statistical information for selected plants

  9. 49 CFR 1242.67 - Switch crews; controlling operations; yard and terminal clerical; locomotive fuel; electric power...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Switch crews; controlling operations; yard and terminal clerical; locomotive fuel; electric power purchased/produced for motive power; operating switches... SERVICE FOR RAILROADS 1 Operating Expenses-Transportation § 1242.67 Switch crews; controlling operations...

  10. Operationality Improvement Control of Electric Power Assisted Wheelchair by Fuzzy Algorithm Considering Posture Angle

    Science.gov (United States)

    Murakami, Hiroki; Seki, Hirokazu; Minakata, Hideaki; Tadakuma, Susumu

    This paper describes a novel operationality improvement control for electric power assisted wheelchairs. “Electric power assisted wheelchair” which assists the driving force by electric motors is expected to be widely used as a mobility support system for elderly people and disabled people, however, the performance of the straight and circular road driving must be further improved because the two wheels drive independently. This paper proposes a novel operationality improvement control by fuzzy algorithm to realize the stable driving on straight and circular roads. The suitable assisted torque of the right and left wheels is determined by fuzzy algorithm based on the posture angular velocity, the posture angle of the wheelchair, the human input torque proportion and the total human torque of the right and left wheels. Some experiments on the practical roads show the effectiveness of the proposed control system.

  11. Generation Companies’ Operative Strategies in the Spot Electricity Market

    Directory of Open Access Journals (Sweden)

    Tovar-Hernández J.H.

    2012-07-01

    Full Text Available In traditional regulation the obligation to meet the consumer demand was assumed, this guaranteed to generation companies the full recovery of their costs. However, in order to achieve greater efficiency, reduce the price of electricity, meet the continuously growing electricity consumption, and equalize prices in different regions, a new structure of the electricity industry has been created, where electric energy is traded through a market. Generation company’s future cash flows depend on day to day market participation, in order to satisfy all of their financial and economic requirements. In this paper, future cash flows required to fulfill with economic and financial commitments by a generation company immerse in this new market structure are studied. For this purpose, future cash flows are considered to be dependent on a single asset: electricity. Several scenarios with different fuel prices are generated in order to estimate the generation company’s future cash flows. The response of the competing generation companies is taken into account at each scenario. The fuel price changes are modelled using a concurrent binary tree.

  12. 76 FR 27669 - Penske Logistics LLC, a Subsidiary of General Electric/Penske Corporation Including On-Site...

    Science.gov (United States)

    2011-05-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,897] Penske Logistics LLC, a Subsidiary of General Electric/Penske Corporation Including On-Site Leased Workers From Kelly Temporary... workers and former workers of Penske Logistics LLC, a subsidiary of General Electric/Penske Corporation...

  13. Rapidly reconfigurable all-optical universal logic gate

    Science.gov (United States)

    Goddard, Lynford L.; Bond, Tiziana C.; Kallman, Jeffrey S.

    2010-09-07

    A new reconfigurable cascadable all-optical on-chip device is presented. The gate operates by combining the Vernier effect with a novel effect, the gain-index lever, to help shift the dominant lasing mode from a mode where the laser light is output at one facet to a mode where it is output at the other facet. Since the laser remains above threshold, the speed of the gate for logic operations as well as for reprogramming the function of the gate is primarily limited to the small signal optical modulation speed of the laser, which can be on the order of up to about tens of GHz. The gate can be rapidly and repeatedly reprogrammed to perform any of the basic digital logic operations by using an appropriate analog optical or electrical signal at the gate selection port. Other all-optical functionality includes wavelength conversion, signal duplication, threshold switching, analog to digital conversion, digital to analog conversion, signal routing, and environment sensing. Since each gate can perform different operations, the functionality of such a cascaded circuit grows exponentially.

  14. Safety in nuclear power plant operation, including commissioning and decommissioning. A code of practice

    International Nuclear Information System (INIS)

    1978-01-01

    Safe operation of a nuclear power plant postulates satisfactory siting, design, construction and commissioning, together with proper management and operation of the plant. This Code of Practice deals with the safety aspects of management, commissioning, operation and decommissioning of the plant. It forms part of the Agency's programme, referred to as the NUSS programme, for establishing Codes of Practice and Safety Guides relating to land-based stationary thermal neutron power plants. It has been prepared for the use of those responsible for the operation of stationary nuclear power plants, the main function of which is the generation of electrical and/or thermal power, and for the use of those responsible for regulating the operation of such plants. It is not intended for application to reactors used solely for experimental or research purposes. The provisions in the Code are designed to provide assurance that operational activities are carried out without undue radiological hazard to the general public and to persons on the site. It should be understood that the provisions in the Code set forth minimum requirements which shall be met in order to achieve safe operation of a nuclear power plant

  15. Operation and planning of coordinated natural gas and electricity infrastructures

    Science.gov (United States)

    Zhang, Xiaping

    Natural gas is becoming rapidly the optimal choice for fueling new generating units in electric power system driven by abundant natural gas supplies and environmental regulations that are expected to cause coal-fired generation retirements. The growing reliance on natural gas as a dominant fuel for electricity generation throughout North America has brought the interaction between the natural gas and power grids into sharp focus. The primary concern and motivation of this research is to address the emerging interdependency issues faced by the electric power and natural gas industry. This thesis provides a comprehensive analysis of the interactions between the two systems regarding the short-term operation and long-term infrastructure planning. Natural gas and renewable energy appear complementary in many respects regarding fuel price and availability, environmental impact, resource distribution and dispatchability. In addition, demand response has also held the promise of making a significant contribution to enhance system operations by providing incentives to customers for a more flat load profile. We investigated the coordination between natural gas-fired generation and prevailing nontraditional resources including renewable energy, demand response so as to provide economical options for optimizing the short-term scheduling with the intense natural gas delivery constraints. As the amount and dispatch of gas-fired generation increases, the long-term interdependency issue is whether there is adequate pipeline capacity to provide sufficient gas to natural gas-fired generation during the entire planning horizon while it is widely used outside the power sector. This thesis developed a co-optimization planning model by incorporating the natural gas transportation system into the multi-year resource and transmission system planning problem. This consideration would provide a more comprehensive decision for the investment and accurate assessment for system adequacy and

  16. Research on electricity market operation mechanism and its benefit of demand side participation

    Science.gov (United States)

    Han, Shuai; Yan, Xu; Qin, Li-juan; Lin, Xi-qiao; Zeng, Bo

    2017-08-01

    Demand response plays an important role in maintaining the economic stability of the system, and has the characteristics of high efficiency, low cost, fast response, good environmental benefits and so on. Demand side resource is an important part of electricity market. The research of demand side resources in our country is still in the initial stage, but the opening of the electricity sales side provides a broad prospect for the development of electricity market. This paper summarizes the main types of demand side resources in our country, analyzes the economic principle of demand response from the micro perspective, puts forward some suggestions on the operation mechanism of China’s demand side resources participating in the electricity market under the condition of electricity sales side opening, analyzes the current situation of pricing in the electricity wholesale market and sets up the pricing strategy of the centralized wholesale market with the demand side power supply participating in quotation, which makes the social and economic benefits reach the maximum.

  17. Demand for electrical energy

    International Nuclear Information System (INIS)

    Bergougnoux, J.; Fouquet, D.

    1983-01-01

    The different utilizations of electric energy are reviewed in the residential and tertiary sectors, in the industry. The competitive position of electricity in regard to other fuels has been strengthned by the sudden rise in the price of oil in 1973-1974 and 1979-1980. The evolution of electricity prices depended on the steps taken to adjust the electricity generation system. The substitution of electricity applications for hydro-carbons is an essential point of energy policy. The adjustment at all times, at least cost and most reliability, of the supply of electricity to the demand for it is a major problem in the design and operation of electric systems. National demand for power at a given moment is extremely diversified. Electricity consumption presents daily and seasonal variations, and variations according to the different sectors. Forecasting power requirements is for any decision on operation or investment relating to an electrical system. Load management is desirable (prices according to the customers, optional tariffs for ''peak-day withdrawal''). To conclude, prospects for increased electricity consumption are discussed [fr

  18. Human factors review of electric power dispatch control centers. Volume 4. Operator information needs. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R.J.; Najaf-Zadeh, K.; Darlington, H.T.; McNair, H.D.; Seidenstein, S.; Williams, A.R.

    1982-10-01

    Human factors is a systems-oriented interdisciplinary specialty concerned with the design of systems, equipment, facilities and the operational environment. An important aspect leading to the design requirements is the determination of the information requirements for electric power dispatch control centers. There are significant differences between the system operator's actions during normal and degraded states of power system operation, and power system restoration. This project evaluated the information the operator requires for normal power system and control system operations and investigates the changes of information required by the operator as the power system and/or the control system degrades from a normal operating state. The Phase II study, published in two volumes, defines power system states and control system conditions to which operator information content can be related. This volume presents detailed data concerning operator information needs that identify the needs for and the uses of power system information by a system operator in conditions ranging from normal through degraded operation. The study defines power system states and control system conditions to which operator information content can be related, and it identifies the requisite information as consistent with current industry practice so as to aid control system designers. Training requirements are also included for planning entry-level and follow-on training for operators.

  19. Site operator program final report for fiscal years 1992 through 1996

    Energy Technology Data Exchange (ETDEWEB)

    Francfort, J.E. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States). Idaho National Engineering and Environmental Lab.; Bassett, R.R. [Sandia National Labs., Albuquerque, NM (United States); Birasco, S. [Los Angeles Dept. of Water and Power, CA (United States)] [and others

    1998-01-01

    The Site Operator Program was an electric vehicle testing and evaluation program sponsored by US Department of Energy and managed at the Idaho National Engineering and Environmental Laboratory. The Program`s goals included the field evaluation of electric vehicles in real-world applications and environments; the support of electric vehicle technology advancement; the development of infrastructure elements necessary to support significant electric vehicle use; and increasing the awareness and acceptance of electric vehicles. This report covers Program activities from 1992 to 1996. The Site Operator Program ended in September 1996, when it was superseded by the Field Operations Program. Electric vehicle testing included baseline performance testing, which was performed in conjunction with EV America. The baseline performance parameters included acceleration, braking, range, energy efficiency, and charging time. The Program collected fleet operations data on electric vehicles operated by the Program`s thirteen partners, comprising electric utilities, universities, and federal agencies. The Program`s partners had over 250 electric vehicles, from vehicle converters and original equipment manufacturers, in their operating fleets. Test results are available via the World Wide Web site at http://ev.inel.gov/sop.

  20. A program to operate the TSI electrical aerosol analyser using an IBM-PC microcomputer - technical background

    International Nuclear Information System (INIS)

    Horton, K.D.; Mitchell, J.P.; Snelling, K.W.

    1988-02-01

    A program has been written to enable the TSI Electrical Aerosol Analyser (EAA model 3030) to be operated using an IBM-PC microcomputer. Although much of the program is based on the software supplied by TSI Inc to collect and process data from the EAA, it incorporates numerous improvements including the option to operate the EAA automatically via a TSI Differential Mobility Particle Sizer interface. When compiled, the program enables the data reduction which takes into account the significant cross-channel sensitivity of the EAA, to be performed in about 30 seconds making it possible to use the EAA to monitor rapid changes in the behaviour of sub-micron aerosol particles. (author)

  1. Brunswick Steam Electric Plant, Units 1 and 2. Annual operating report for 1976

    International Nuclear Information System (INIS)

    1977-01-01

    Net electrical energy generated by Unit 1 was 30,399 MWH with the generator on line 334.5 hrs. Unit 2 generated 2,481,014 MWH with the generator on line 4,915.53 hrs. Information is presented concerning operations, shutdowns and power reductions, maintenance, power generation, modifications, changes to operational procedures, radiation exposures, and leak rate testing

  2. Impact of electric vehicles in the steady state operation of distribution systems

    OpenAIRE

    Erasmo Saraiva de Castro

    2015-01-01

    This work aims to quantify the impact in the steady state operation of a distribution system when electric vehicles are connected. It is worth noting that the connection of them may cause significant changes in the voltage profile, in the degree of voltage unbalance and in the electrical losses of the system. In order to make this analysis, a three-phase power flow program was developed in MATLAB language. This program is based on the Ladder Iterative Technique and it contains models of overh...

  3. Electric cars for all? DLR analyses the potential of utilization of the electro-mobility; Elektroautos fuer alle? DLR analysiert Nutzungspotenzial der Elektromobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Mehlin, Markus [DLR Deutsches Zentrum fuer Luft- und Raumfahrt e.V., Berlin (Germany). Inst. fuer Verkehrsforschung

    2009-09-15

    The electric car has invited considerable interest: As many as four ministries had invited scientists and politicians of all conceivable fields to a national conference of strategy in November 2008 in order to discuss the national development plan on electrical mobility. The parallel exhibition showed vehicles of newer and older initiatives such as the small vehicle CityEl, modified vehicles in which batteries are installed instead of the rear seat, or the flagship which stated the advance of the electric cars, the Tesla Roadster.

  4. The Liberalisation of the Electricity Market in Italy

    International Nuclear Information System (INIS)

    Dessenibus, A.; Viskovic, A.; Carollo, T.

    2001-01-01

    The electricity sector is under reform in all EU countries on both of the aspects of market organisation and Utilities' restructuring, the latter being a consequence of the former. Until very recently, most governments have considered the whole power sector to be a natural monopoly and therefore it should be closely regulated. Market liberalisation shifts decision-making from the State to the market and, for the first time in the history of electricity Utility, gives consumer a choice. The new framework is featured by the introduction of competition in electricity generation and end-users' supply, non-discriminatory access to the electricity network and a redefinition of the regulatory function of governments. This study briefly resumes the market reforms and the new market organisation in Italy. Italy has implemented the EU directive on internal electricity market since 1999. So far, the process of market liberalisation has not come to an end yet. Currently ENEL, the former vertically integrated monopolist, is dismissing 25 percent of its power generation capacity, by selling in the market three power generation companies (GENCOs). An independent Transmission System Operator is fully operative since July 1999 and a transparent and non-discriminatory access to the network is guaranteed to all of the electricity power generation companies. The Market Pool Operator is defining the code of the Market Pool that will be applied to the price settlement into the Pool. The opening of the market on the demand side is growing year by year, according to the enlargement of the consumers who are allowed to sign freely contracts of supply with distributors (eligible consumers). Three months after the selling of the third Genco, the eligibility threshold will be lowered at 0.1 GWh. At that time, the open market is expected to represent 70 percent of the overall electricity consumption in Italy. Available evidence on liberalisation process in United Kingdom and in Scandinavian

  5. Polarization encoded all-optical multi-valued shift operators

    Science.gov (United States)

    Roy, Jitendra Nath; Bhowmik, Panchatapa

    2014-08-01

    Polarization encoded multi-valued (both ternary and quaternary logic) shift operators have been designed using linear optical devices only. There are six ternary and 24 quaternary shift operators in multi-valued system. These are also known as reversible literals. This circuit will be useful in future all-optical multi-valued logic based information processing system. Different states of polarization of light are taken as different logic states.

  6. On Some Extensions of Szasz Operators Including Boas-Buck-Type Polynomials

    Directory of Open Access Journals (Sweden)

    Sezgin Sucu

    2012-01-01

    Full Text Available This paper is concerned with a new sequence of linear positive operators which generalize Szasz operators including Boas-Buck-type polynomials. We establish a convergence theorem for these operators and give the quantitative estimation of the approximation process by using a classical approach and the second modulus of continuity. Some explicit examples of our operators involving Laguerre polynomials, Charlier polynomials, and Gould-Hopper polynomials are given. Moreover, a Voronovskaya-type result is obtained for the operators containing Gould-Hopper polynomials.

  7. Electric motor for laser-mechanical drilling

    Science.gov (United States)

    Grubb, Daryl L.; Faircloth, Brian O.; Zediker, Mark S.

    2017-10-10

    A high power laser drilling system utilizing an electric motor laser bottom hole assembly. A high power laser beam travels within the electric motor for performing a laser operation. A system includes a down hole electrical motor having a hollow rotor for conveying a high power laser beam having a wavelength less than 1060 nm through the electrical motor.

  8. Nuclear energy in the operation of the spanish electric system

    International Nuclear Information System (INIS)

    Atienza, L.

    2008-01-01

    Nuclear energy plays a basic role in electricity production in Spain. Its high availability rate, the predictability of its fuel recharges, its high operational reliability, its geographical location, the stability of its costs, with its fuel having low weight in the cost structure, the security of supply that the possibility of storing its fuel on-site in the power plant gives and the absence of CO 2 emissions are some of the advantages nuclear energy presents. Its stiffness for demand variations, its sudden disconnections, which are infrequent but with high impact on System Operation, the social perception and nuclear waste management must also be weighted up. (Author)

  9. Monitoring of good practices programs and independence for electricity and natural gas system operators in 2015 and 2016. Follow-up report, January 2017

    International Nuclear Information System (INIS)

    2017-01-01

    Electricity and natural gas transmission system operators (TSO) and distribution system operators (DSO) are regulated operators that provide public service functions for the benefit of the network users and the consumers they serve. Accordingly, European and French law requires that they be under independent and nondiscriminatory obligations. In particular, they must develop a good practices program which includes a range of measures to prevent the risk of discriminatory practices in network access. Pursuant to Article L.134-15 of the Energy Code, the Energy Regulatory Commission (CRE) is publishing this year its 10. annual report on the monitoring of good practices programs and independence for electricity and natural gas system operators for the 2015-2016 period. This report is based on analysis of the 'reports on the implementation of good practices programs' submitted to the CRE by the operators in 2015-2016 and audits carried out by the CRE services in these companies during the same period

  10. Opportunities for Joint Water–Energy Management: Sensitivity of the 2010 Western U.S. Electricity Grid Operations to Climate Oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Voisin, N. [Pacific Northwest National Laboratory, Richland, Washington; Kintner-Meyer, M. [Pacific Northwest National Laboratory, Richland, Washington; Wu, D. [Pacific Northwest National Laboratory, Richland, Washington; Skaggs, R. [Pacific Northwest National Laboratory, Richland, Washington; Fu, T. [Pacific Northwest National Laboratory, Richland, Washington; Zhou, T. [Pacific Northwest National Laboratory, Richland, Washington; Nguyen, T. [Pacific Northwest National Laboratory, Richland, Washington; Kraucunas, I. [Pacific Northwest National Laboratory, Richland, Washington

    2018-02-01

    The 2016 SECURE Water Act report’s natural water availability benchmark, combined with the 2010 level of water demand from an integrated assessment model, is used as input to drive a large-scale water management model. The regulated flow at hydropower plants and thermoelectric plants in the Western U.S. electricity grid (WECC) is translated into potential hydropower generation and generation capacity constraints. The impact on reliability (unserved energy, reserve margin) and cost (production cost, carbon emissions) of water constraints on 2010-level WECC power system operations is assessed using an electricity production cost model (PCM). Use of the PCM reveals the changes in generation dispatch that reflect the inter-regional interdependencies in water-constrained generation and the ability to use other generation resources to meet all electricity loads in the WECC. August grid operational benchmarks show a range of sensitivity in production cost (-8 to +11%) and carbon emissions (-7 to 11%). The reference reserve margin threshold of 15% above peak load is maintained in the scenarios analyzed, but in 5 out of 55 years unserved energy is observed when normal operations are maintained. There is 1 chance in 10 that a year will demonstrate unserved energy in August, which defines the system’s historical performance threshold to support impact, vulnerability, and adaptation analysis. For seasonal and longer term planning, i.e., multi-year drought, we demonstrate how the Water Scarcity Grid Impact Factor and climate oscillations (ENSO, PDO) can be used to plan for joint water-electricity management to maintain grid reliability.

  11. DOE Fundamentals Handbook: Electrical Science, Volume 2

    International Nuclear Information System (INIS)

    1992-06-01

    The Electrical Science Fundamentals Handbook was developed to assist nuclear facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding terminology, and application. The handbook includes information on alternating current (AC) and direct current (DC) theory, circuits, motors, and generators; AC power and reactive components; batteries; AC and DC voltage regulators; transformers; and electrical test instruments and measuring devices. This information will provide personnel with a foundation for understanding the basic operation of various types of DOE nuclear facility electrical equipment

  12. Effects of 60 Hz electric fields on operant and social stress behaviors of nonhuman primates

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, W.R.; Coelho, A.M. Jr.; Easley, S.P.; Lucas, J.H.; Moore, G.T.; Orr, J.L.; Smith, H.D.; Taylor, L.L.; Tuttle, M.L.

    1987-10-24

    The objective of this program is to investigate, using the baboon as a nonhuman primate surrogate for the human, possible behavioral effects associated with exposure to high intensity 60 Hz electric fields. Results from this program, along with information from experiments conducted elsewhere, will be used by the Department of Energy (DOE) to estimate and evaluate the likelihood of deleterious consequences resulting from exposure of humans to the electric fields associated with power transmission over high voltage lines. This research program consists of four major research projects, all of which have been successfully completed. The first project evaluated the potentially aversive character of exposure to 60 Hz electric fields by determining the threshold intensity that produces escape or avoidance responses. The second project estimated the threshold intensity for detection threshold was 12 kV/m; the range of means was 6 to 16 kV/m. The third project assessed, in separate experiments conducted at 30 and 60 kV/m, effects of chronic exposure to electric fields on the performance of two operant conditioning tasks, fixed ratio (FR), and differential reinforcement of low rate (DRL). In the same two experiments, the fourth project investigated, using the systematic quantitative observational sampling methods of primatology, the possible stress-inducing effects of chronic exposure to 60 Hz electric fields on the behavior of baboons living in small social groups. 131 refs., 87 figs., 123 tabs.

  13. Reliability through markets in Ontario : submission by the Independent Electricity Market Operator to the Minister of Energy's Consultation Process

    International Nuclear Information System (INIS)

    2003-01-01

    For the past five years, Ontario has invested $1 billion to restructure and open its electricity market to competition. In recent months, and in response to residential consumers pricing concerns, the Independent Electricity Market Operator (IMO) transferred credits to local distribution companies allowing them to issue $75 rebates to all affected customers as of December 1, 2002, and to bill low-volume and other designated customers at a rate of 4.3 cents per kilowatt hour for the commodity portion of their bills. This report addresses the concern that price responsiveness will be lost for those parts of the market with fixed prices. It was noted that the reliability of the power system could be placed at risk if the range of customers with fixed prices is broadened. Fixed prices would also jeopardize the province's ability to attract new supply and enhance competition in the electricity sector. The IMO believes that price responsiveness in the wholesale market is crucial to the reliability of the electricity system and recommends that a plan for any additional fixed pricing should include a clearly defined phase-out over the period ending in 2006 as new supply comes on-line. The IMO emphasizes that the lack of price responsiveness to the market, particularly in peak energy demand periods, is equivalent to adding hundreds of MW to the load. The report presents lessons learned in other jurisdictions and highlights noteworthy considerations such as the market power mitigation agreement, improving competition, a phased-in approach, and demand side initiatives

  14. Electrical and non-electrical environment of wind turbine main components

    DEFF Research Database (Denmark)

    Holboell, J.; Henriksen, M.; Olsen, R.S.

    of the electrical components or even lead to catastrophic component failure. In the present paper, results are presented from investigations on existing standards which give detailed descriptions of the environmental and operational conditions of wind turbine components. It is found that there is currently a lack...... of application standards for wind turbine electrical equipment. Component-level environmental requirements as given in equipment-specific standards are compared with the environment described in the IEC's 61400 series concerning wind turbines. Based on methods defined in IEC 60721, the non-electrical environment...... of wind turbine is described by means of specific classes. In the paper, new class combinations are suggested covering the different operating conditions the components are exposed to. The class combinations include factors of climatic, mechanical and chemical character. The factors occur in different...

  15. Britain's Nuclear Electric pursues a major programme to enhance safety

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    The UK state-owned nuclear utility, Nuclear Electric, is actively pursuing a major initiative inherited from its predecessor the Central Electricity Generating Board, known as the Station Enhancement Programme. The Enhancement Programme is a multi-million pound project and covers all Nuclear Electric's stations (including relevant aspects of the de-commissioning site at Berkeley). Its fundamental objective is to enhance the arrangements, practices and attitudes on the power stations to create an overall environment likely to promote ever safer and more reliable operation, and to take full account of the best international practices. The four year programme started in the spring of 1989, and is expected to be completed in 1993. Key elements of the programme include quality assurance based management systems; improvements to site and plant material conditions; a more formal approach to training; additional resources and controls to aid the management of maintenance defects; higher profile for the feedback of operational experience; management targets; a station evaluation programme; and formal feedback of lessons learned from the IAEA operational and safety review team visit to the Oldbury-on-Severn station in 1989. (author)

  16. Effects of 60 Hz electric fields on operant and social stress behavior of nonhuman primates. Quarterly technical progress report No. 20, September 28-December 20, 1985

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, W.R.

    1986-01-03

    This research program will evaluate the aversive character of exposure to 60 Hz electric fields by determining the threshold intensity which produces avoidance or escape responses, will estimate the threshold intensity for detection of 60 Hz electric fields, will assess effects of chronic exposure to 60 Hz electric fields on the performance of two operant conditioning tasks, fixed ratio and differential reinforcement of low rate responding, will investigate, using the systematic quantitative observational sampling methods of primatology, the possible stress-inducing effects of chronic exposure to 60 Hz electric fields on the behavior of baboons living in small social groups. In all experiments, the electric fields will be described, characterized, and controlled to account for recognized artifacts associated with high intensity 60 Hz electric fields and the health of all subjects will be described using the methods of primate veterinary medicine.

  17. Electric power substations engineering

    CERN Document Server

    2003-01-01

    This book covers all aspects of substations, from the initial concept to design, automation, operation, and physical and cyber security. Written by members of the Institute of Electrical and Electronic Engineers (IEEE) Power Engineering Society (PES) Substations Committee, each section provides a tutorial and includes references for further reading and study. The authors use photographs and graphics to help the reader understand the material. Exploring the most recent technological developments regarding industry practice and standards, the book provides an extensive overview of substations th

  18. Conceptual Design of Electrical Propulsion System for Nuclear Operated Vessel Adventurer

    International Nuclear Information System (INIS)

    Halimi, B.; Suh, K. Y.

    2009-01-01

    A design concept of the electric propulsion system for the Nuclear Operated Vessel Adventure (NOVA) is presented. NOVA employs Battery Omnibus Reactor Integral System (BORIS), a liquid metal cooled small fast integral reactor, and Modular Optimized Brayton Integral System (MOBIS), a supercritical CO 2 (SCO 2 ) Brayton cycle as power converter to Naval Application Vessel Integral System (NAVIS)

  19. Development of a multi-mode hybrid electric bus

    Energy Technology Data Exchange (ETDEWEB)

    Shemmans, M.J. [Overland Custom Coach, Thorndale, ON (Canada); Bland, C. [BET Services Inc., Mississauga, ON (Canada)

    2004-04-01

    This paper describes the development of an energy efficient, low floor, 28 foot hybrid electric bus for use as an airport shuttle bus or other specialized transit operations. A multi-mode concept was also adopted to include the capability of operating in battery-only drive, engine-only drive or a range of hybrid electric drive modes. The electric drivetrain was powered by a battery pack or a combination of a battery pack and an internal combustion engine-powered electric generator. The participating companies in this project include Overland Custom Coach, BET Services Inc., Siemens and Transport Canada. The technical feasibility study was described with reference to duty cycles, performance issues, vehicle weight, mechanical drive issues, brakes, suspension, powertrain cooling, heating, ventilation, electrical system, batteries and control system. The commercial feasibility was also described in terms of capital and operating costs. Results of the prototype tests validate the possibilities of zero or reduced emission transit in real world applications. 25 tabs., 32 figs.

  20. Coordinated Operation of the Electricity and Natural Gas Systems with Bi-directional Energy Conversion

    DEFF Research Database (Denmark)

    Zeng, Qing; Zhang, Baohua; Fang, Jiakun

    2017-01-01

    A coordinated operation of the natural gas and electricity network with bi-directional energy conversion is expected to accommodate high penetration levels of renewables. This work focuses on the unified optimal operation of the integrated natural gas and electricity system considering the network...... constraints in both systems. An iterative method is proposed to deal with the nonlinearity in the proposed model. The models of the natural gas and power system are linearized in every iterative step. Simulation results demonstrate the effectiveness of the approach. Applicability of the proposed method...... is tested in the sample case. Finally, the effect of Power to Gas (P2G) on the daily economic dispatch is also investigated....

  1. Risk management and market efficiency on the Midwest Independent System Operator electricity exchange

    Science.gov (United States)

    Jones, Kevin

    Midwest Independent Transmission System Operator, Inc. (MISO) is a non-profit regional transmission organization (RTO) that oversees electricity production and transmission across thirteen states and one Canadian province. MISO also operates an electronic exchange for buying and selling electricity for each of its five regional hubs. MISO oversees two types of markets. The forward market, which is referred to as the day-ahead (DA) market, allows market participants to place demand bids and supply offers on electricity to be delivered at a specified hour the following day. The equilibrium price, known as the locational marginal price (LMP), is determined by MISO after receiving sale offers and purchase bids from market participants. MISO also coordinates a spot market, which is known as the real-time (RT) market. Traders in the real-time market must submit bids and offers by thirty minutes prior to the hour for which the trade will be executed. After receiving purchase and sale offers for a given hour in the real time market, MISO then determines the LMP for that particular hour. The existence of the DA and RT markets allows producers and retailers to hedge against the large fluctuations that are common in electricity prices. Hedge ratios on the MISO exchange are estimated using various techniques. No hedge ratio technique examined consistently outperforms the unhedged portfolio in terms of variance reduction. Consequently, none of the hedge ratio methods in this study meet the general interpretation of FASB guidelines for a highly effective hedge. One of the major goals of deregulation is to bring about competition and increased efficiency in electricity markets. Previous research suggests that electricity exchanges may not be weak-form market efficient. A simple moving average trading rule is found to produce statistically and economically significant profits on the MISO exchange. This could call the long-term survivability of the MISO exchange into question.

  2. Research Capabilities Directed to all Electric Engineering Teachers, from an Alternative Energy Model

    Directory of Open Access Journals (Sweden)

    Víctor Hugo Ordóñez Navea

    2017-08-01

    Full Text Available The purpose of this work was to contemplate research capabilities directed to all electric engineering teachers from an alternative energy model intro the explanation of a semiconductor in the National Training Program in Electricity. Some authors, such as. Vidal (2016, Atencio (2014 y Camilo (2012 point out to technological applications with semiconductor electrical devices. In this way; a diagnostic phase is presented, held on this field research as a descriptive type about: a how to identify the necessities of alternative energies, and b The research competences in the alternatives energies of researcher from a solar cell model, to boost and innovate the academic praxis and technologic ingenuity. Themselves was applied a survey for a group of 15 teachers in the National Program of Formation in electricity to diagnose the deficiencies in the research area of alternatives energies. The process of data analysis was carried out through descriptive statistic. Later the conclusions are presented the need to generate strategies for stimulate and propose exploration of alternatives energies to the development of research competences directed to the teachers of electrical engineering for develop the research competences in the enforcement of the teachers exercise for the electric engineering, from an alternative energy model and boost the technologic research in the renewal energies field.

  3. Electric and Hybrid Vehicle Program: Site Operation Program. Quarterly progress report, July--September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Francfort, J.; Bassett, R.R.; Briasco, S. [and others

    1995-12-01

    The Site Operator Program has evolved substantially since its inception in response to the Electric Vehicle Research and Demonstration Act of 1976. In its original form, a commercialization effort was intended but this was not feasible for lack of vehicle suppliers and infrastructure. Nonetheless, with DOE sponsorship and technical participation, a few results (primarily operating experience and data) were forthcoming. The current Program comprises eleven sites and over 200 vehicles, of which about 50 are latest generation vehicles. DOE partially funds the Program participant expenditures and the INEL receives operating and maintenance data for the DOE-owned, and participant-owned or monitored vehicles, as well as Program reports. As noted elsewhere in this report, participants represent several widely differing categories: electric utilities, academic institutions, and federal agencies. While both the utilities and the academic institutions tend to establish beneficial relationships with the industrial community.

  4. Maritime Electric Co. Ltd. annual report, 1992

    International Nuclear Information System (INIS)

    1992-01-01

    Maritime Electric Company is a Canadian investor-owned electric utility based in Prince Edward Island. Established in 1918, the Company owns and operates a fully integrated system providing for the generation, transmission, and distribution of electricity throughout the Island. Maritime Electric operates generating plants in Charlottetown and Borden, and has an equity interest in NB Power's unit in Dalhousie, New Brunswick. Its 4,400 km distribution system and 560 km transmission system are linked to the mainland power grid by two submarine cables between the Island and the province of New Brunswick. This report describes the Company's operations, power production and sales for the year, with relevant statistical information. Financial statements are also included. In 1992 the Victoria Cross distribution substation was rebuilt. Earnings per share in 1992 were $1.85 compared with $1.79 in 1991. Demand side management initiatives were further enhanced and the plant life extension program continued at the Charlottetown Generating Plant. A ten year summary is included. 7 figs

  5. Developing Efficient Urban Electrical Systems Using Microgrids

    Energy Technology Data Exchange (ETDEWEB)

    Gahagan, Michael

    2010-09-15

    Electric vehicles and battery storage will complicate utility operations and strain existing networks. One possible solution is the implementation of 'microgrids' autonomous electricity environments that operate within a larger electric utility grid and their 'controllers' Microgrids direct locally generated power to local demand, coordinate with centralized utility networks to meet additional demand, and pass excess supply to neighboring microgrids. This paper explains the evolution of microgrids. It details their design and operation. It also reviews their many benefits within urban settings, including minimizing customer costs while maximizing use of local generation from clean, renewable resources.

  6. Hybrid Systems of Distributed Generation with Renewable Sources: Modeling and Analysis of Their Operational Modes in Electric Power System

    Directory of Open Access Journals (Sweden)

    A. M. Gashimov

    2013-01-01

    Full Text Available The paper considers problems pertaining to modeling and simulation of operational hybrid system modes of the distributed generation comprising conventional sources – modular diesel generators, gas-turbine power units; and renewable sources – wind and solar power plants. Operational modes of the hybrid system have been investigated under conditions of electrical connection with electric power system and in case of its isolated operation. As a consequence

  7. Trade in electricity certificates: a new means for stimulating electricity from renewable energy sources: final report from the electricity certificate inquiry

    International Nuclear Information System (INIS)

    2001-01-01

    We recommend the introduction of a quota-based Swedish certificate system to promote production of electricity from renewable energy sources commencing on 1 January 2003. We recommend that the certificate system should be based on the following principles: The quota obligation should be set for the years 2003 to 2010 and for all intervening years. The quota is expressed as a share of the total amount of electricity used. It is proposed that as a guideline, a target of an increase in electricity production from renewable energy sources of 10 TWh, in a period from 2003 to 2010 inclusive, is adopted. It is estimated that approximately half of this increase can come from expansion of existing production and half from new plants. The following electricity production plants are to be entitled to certificates provided they comply with the requirement that electricity is to be produced from renewable energy sources and that they meet the environmental criteria set, including fuel requirements, where electricity is produced with the aid of: 1. wind power, 2. solar energy, 3. geothermal energy, 4. certain types of biofuel, 5. wave energy, 6. hydroelectric power at existing plants which, at the time of the Electricity Certificate law coming into effect, have a capacity not exceeding 1 500 kilowatt, 7. hydroelectric power at plants which have not been in operation after 1 July 2001 but which were commissioned after the coming into effect of the Electricity Certificate law, 8. increased installed capacity at existing hydroelectric power plants to the extent that capacity is increased by measures undertaken after 1 July 2002, and 9. hydroelectric power produced at plants, which started operation for the first time after 1 July 2002. The quota period is defined as one calendar year. Certificates may be 'banked' by those subject to quota should they have more certificates at the end of the quota period than need to be submitted. A certificate is valid for an unlimited period of

  8. Obedience to compliance programs and independence for electricity and natural gas system operators. 2009 report

    International Nuclear Information System (INIS)

    2009-12-01

    In France, system operators belong to groups that also conduct business in the energy sector, in fields governed by competition rules. They could therefore be tempted to use their privileged position to their group's benefit, which would disadvantage end consumers. Non-discriminatory access to electricity and gas transmission and distribution networks is at the core of the market opening to competition approach implemented by the European Union since the end of the 1990's. EU and national enactments in force highlight two tools to ensure nondiscrimination: compliance programmes and independence of system operators with regard to their parent companies. Firstly, compliance programs contain measures taken to ensure that discrimination is completely excluded and that their application is subject to appropriate monitoring. Secondly, system operator independence plays a part in preventing discrimination against competitors with other business activities (generation, supply, etc.) within the same group. In application of these enactments, every electricity or natural gas transmission or distribution system operator serving more than 100,000 customers provided CRE, the Energy Regulatory Commission, with their annual reports on the application of their compliance programs. This document is CRE's 2009 report about compliance programmes and independence of electricity and natural gas system operators. Its content can be summarized as follows: 1 - system operator independence serving consumers: Non-discriminatory access to networks is essential for the development of competitive markets, System operator compliance programs and independence act as a guarantee of nondiscrimination, The legal context in which these issues are addressed is set to change in the near future; 2 - A high level of obedience to compliance programs: The continued efforts of system operators prevent discrimination, CR E has assessed distribution system operators by means of a mystery

  9. The French electricity report 2009

    International Nuclear Information System (INIS)

    2010-01-01

    RTE is the company responsible for running the French electricity transmission system. It is a public service operator, tasked with operating, maintaining and developing the high and extra high voltage network. It guarantees the reliability and proper operation of the power network. These missions were entrusted to it by the Law of 10 February 2000. With 100,000 km of lines between 63,000 and 400,000 volts and 45 cross-border lines, the network operated by RTE is the biggest in Europe. In 2008, RTE posted turnover of euros 4,221 m and currently employs around 8,500 staff. RTE, by virtue of the missions entrusted to it by the Law of 10 February 2000, is the central player in the French power system. For the purpose of maintaining the real time balance between supply and demand, and managing contractual relations with customers connected to its network, RTE monitors all the electrical energy that enters and leaves the public transmission system. Through its management of the 45 interconnection lines linking France with its neighbours, RTE also tracks all import and export data, on behalf of players in the French and European electricity market. RTE constantly records and examines data provided by all market players. Using the data, monthly and annually, it publishes exhaustive figures for the French power system (demand, generation, imports and exports), which offer the only truly accurate reflection of the real state of the sector's economy. This report presents these figures for the year 2009. Contents: 1 - French electricity demand down by 1.6% on 2008; 2 - A drop in French electricity generation; 3 - The balance of cross-border exchanges falls, but remains positive; 4 - RTE continues to invest in a robust network capable of keeping up with developments in the electricity industry; 5 - Appendix 1: New infrastructures on the RTE network in 2009; 6 - Appendix 2: Electricity quality; 7 - Appendix 3: Mature market mechanisms

  10. Cheap electricity from French tides

    Science.gov (United States)

    Andre, H.

    1980-02-01

    A tidal power plant built in Saint-Malo, France is examined, and some of the problems that have resulted in recent years are analyzed. These include mechanical problems due to turbine runner-blade seal failure and electrical problems involving electroerosion and structural station difficulties. the effects of tidal power plants on the environment are discussed, and it is noted that all possible side effects of the operations are very limited. Attention is given to the basic requirements for constructing power sites.

  11. All Electric Passenger Vehicle Sales in India by 2030: Value proposition to Electric Utilities, Government, and Vehicle Owners

    Energy Technology Data Exchange (ETDEWEB)

    Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gopal, Anand R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sheppard, Colin [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-06-20

    In India, there is growing interest among policymakers, planners, and regulators for aggressive electrification of passenger vehicles. For example, Piyush Goyal, the Minister of State for India’s Ministry of Coal, Power, New and Renewable Energy, announced an aspirational goal of converting all vehicle sales in India to battery electric vehicles (BEVs) by 2030 (Economic Times, 2016). In 2012, India has already announced the National Mission on Electric Mobility (NMEM) sets a countrywide goal of deploying 6 to 7 million hybrid and electric vehicles (EVs) by 2020 (DHI, 2012). A major policy motivation for transport electrification is to reduce India’s oil import dependency. The objective of this paper is to assess the effect of full electrification of vehicle sales in India by 2030 on the key stakeholders such as BEV owners, electric utilities, and the government. Specifically, we attempt to answer the following questions: (a) How does the total vehicle ownership cost of BEVs compare with the conventional vehicles? (b) What is the additional load due BEV charging? (c) What is the impact on the power sector investments, costs, and utility revenue? (d) How can smart BEV charging help renewable energy grid integration? (e) What is the impact on the crude oil imports? (f) What is the impact on the greenhouse gas (GHG) emissions?

  12. A Kantorovich-Stancu Type Generalization of Szasz Operators including Brenke Type Polynomials

    Directory of Open Access Journals (Sweden)

    Rabia Aktaş

    2013-01-01

    Full Text Available We introduce a Kantorovich-Stancu type modification of a generalization of Szasz operators defined by means of the Brenke type polynomials and obtain approximation properties of these operators. Also, we give a Voronovskaya type theorem for Kantorovich-Stancu type operators including Gould-Hopper polynomials.

  13. The projected costs of electricity generation

    International Nuclear Information System (INIS)

    Cameron, R.; Keppler, J. H.

    2010-10-01

    This paper describes the outcomes from the joint report between the Nuclear Energy Agency and the International Energy Agency of the OECD on the projected costs of generating electricity. The study contains data on electricity generating costs for almost 200 power plants provided by 17 OECD member countries, 4 non-OECD countries and 4 industrial companies or industry organisations. The paper presents the projected costs of generating electricity calculated according to common methodological rules on the basis of the data provided by participating countries and organisations. Data were received for a wide variety of fuels and technologies, including coal, gas, nuclear, hydro, onshore and offshore wind, biomass, solar, wave and tidal. Cost estimates were also provided for combined heat and power plants, as well as for coal plants that include carbon capture. As in previous studies of the same series, all costs and benefits were discounted or capitalised to the date of commissioning in order to calculate the state of the electricity costs per MWh, based on plant operating lifetime data. In addition, the paper contains a discussion of a number of factors affecting the cost of capital, the outlook for carbon capture and storage and the working of electricity markets. (Author)

  14. Upgraded safety analysis document including operations policies, operational safety limits and policy changes. Revision 2

    International Nuclear Information System (INIS)

    Batchelor, K.

    1996-03-01

    The National Synchrotron Light Source Safety Analysis Reports (1), (2), (3), BNL reports number-sign 51584, number-sign 52205 and number-sign 52205 (addendum) describe the basic Environmental Safety and Health issues associated with the department's operations. They include the operating envelope for the Storage Rings and also the rest of the facility. These documents contain the operational limits as perceived prior or during construction of the facility, much of which still are appropriate for current operations. However, as the machine has matured, the experimental program has grown in size, requiring more supervision in that area. Also, machine studies have either verified or modified knowledge of beam loss modes and/or radiation loss patterns around the facility. This document is written to allow for these changes in procedure or standards resulting from their current mode of operation and shall be used in conjunction with the above reports. These changes have been reviewed by NSLS and BNL ES and H committee and approved by BNL management

  15. Electric theory

    International Nuclear Information System (INIS)

    Gong, Ha Seong

    2006-02-01

    This book explains electric theory which is divided into four chapters. The first chapter includes electricity and material, electric field, capacitance, magnetic field and electromagnetic force, inductance. The second chapter mentions electronic circuit analysis, electric resistance,heating and power, chemical activity on current and battery with electrolysis. The third chapter deals with an alternating current circuit about the basics of an AC circuit, operating of resistance, inductance and capacitance, series circuit and parallel circuit of PLC, an alternating current circuit, Three-phase Alternating current, two terminal pair network and voltage and current of non-linearity circuit. The last explains transient phenomena of RC series circuit, RL series circuit, transient phenomena of an alternating current circuit and transient phenomena of RLC series circuit.

  16. All-optical fast random number generator.

    Science.gov (United States)

    Li, Pu; Wang, Yun-Cai; Zhang, Jian-Zhong

    2010-09-13

    We propose a scheme of all-optical random number generator (RNG), which consists of an ultra-wide bandwidth (UWB) chaotic laser, an all-optical sampler and an all-optical comparator. Free from the electric-device bandwidth, it can generate 10Gbit/s random numbers in our simulation. The high-speed bit sequences can pass standard statistical tests for randomness after all-optical exclusive-or (XOR) operation.

  17. Using virtual reality technology to include field operators in simulation and training

    International Nuclear Information System (INIS)

    Nystad, E.; Strand, S.

    2006-01-01

    By using virtual reality technology, field operators can be included in simulator training. A study has been performed where field operators could perform their activities in a virtual plant and communicate with a control room operator who was placed in a physical control room simulator. This paper describes the use of VR technology in the study and how the operators experienced interacting with the virtual plant. (author)

  18. Online Energy Management of Plug-In Hybrid Electric Vehicles for Prolongation of All-Electric Range Based on Dynamic Programming

    Directory of Open Access Journals (Sweden)

    Zeyu Chen

    2015-01-01

    Full Text Available The employed energy management strategy plays an important role in energy saving performance and exhausted emission reduction of plug-in hybrid electric vehicles (HEVs. An application of dynamic programming for optimization of power allocation is implemented in this paper with certain driving cycle and a limited driving range. Considering the DP algorithm can barely be used in real-time control because of its huge computational task and the dependence on a priori driving cycle, several online useful control rules are established based on the offline optimization results of DP. With the above efforts, an online energy management strategy is proposed finally. The presented energy management strategy concerns the prolongation of all-electric driving range as well as the energy saving performance. A simulation study is deployed to evaluate the control performance of the proposed energy management approach. All-electric range of the plug-in HEV can be prolonged by up to 2.86% for a certain driving condition. The energy saving performance is relative to the driving distance. The presented energy management strategy brings a little higher energy cost when driving distance is short, but for a long driving distance, it can reduce the energy consumption by up to 5.77% compared to the traditional CD-CS strategy.

  19. Results from Operational Testing of the Siemens Smart Grid-Capable Electric Vehicle Supply Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, Brion [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    The Idaho National Laboratory conducted testing and analysis of the Siemens smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from Siemens for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the Siemens smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

  20. Drive Control Scheme of Electric Power Assisted Wheelchair Based on Neural Network Learning of Human Wheelchair Operation Characteristics

    Science.gov (United States)

    Tanohata, Naoki; Seki, Hirokazu

    This paper describes a novel drive control scheme of electric power assisted wheelchairs based on neural network learning of human wheelchair operation characteristics. “Electric power assisted wheelchair” which enhances the drive force of the operator by employing electric motors is expected to be widely used as a mobility support system for elderly and disabled people. However, some handicapped people with paralysis of the muscles of one side of the body cannot maneuver the wheelchair as desired because of the difference in the right and left input force. Therefore, this study proposes a neural network learning system of such human wheelchair operation characteristics and a drive control scheme with variable distribution and assistance ratios. Some driving experiments will be performed to confirm the effectiveness of the proposed control system.

  1. Sizewell integrated system for centralized operations: getting it all together

    International Nuclear Information System (INIS)

    Cook, B.M.; Robinson, D.E.P.

    1992-01-01

    In June 1991, Westinghouse was awarded a contract by Nuclear Electric to supply the Integrated System for Centralized Operations (ISCO) for the Sizewell B nuclear power plant under construction in Suffolk. This system is a large scale distributed control and instrumentation system that will perform safety and control functions for the primary and secondary systems for the plant. Combined with the control and instrumentation equipment that was already being supplied for the plant by Westinghouse, this will be the most extensive integration of modern digital control equipment on a nuclear power plant to date. The ISCO architecture, consisting of 3 major segments -high integrity control, process control and the distributed computer system - is described. The history of the ISCO development is explained. (Author)

  2. Station blackout: Deterministic and probabilistic approach in the field of electrical supply losses by EDF

    International Nuclear Information System (INIS)

    Meslin, T.; Carnino, A.

    1986-01-01

    This example shows the thoroughness of EDF's approach in processing the difficult problems of the loss of electrical power supplies. Efforts are continuing in several directions: continued revision and improvement of operating procedures in the event of loss of electrical power supplies, PWR plant operator training courses devoted to the problems of power supply losses, and continued testing on simulators, and particularly testing under real conditions, including tests lasting several hours made possible by the performance of the new EDF simulators (two-phase code and taking all power losses into account)

  3. A Study on the Operation Strategy for Combined Accident including TLOFW accident

    International Nuclear Information System (INIS)

    Kim, Bo Gyung; Kang, Gook Young; Yoon, Ho Joon

    2014-01-01

    It is difficult for operators to recognize the necessity of a feed-and-bleed (F-B) operation when the loss of coolant accident and failure of secondary side occur. An F-B operation directly cools down the reactor coolant system (RCS) using the primary cooling system when residual heat removal by the secondary cooling system is not available. The plant is not always necessary the F-B operation when the secondary side is failed. It is not necessary to initiate an F-B operation in the case of a medium or large break because these cases correspond to low RCS pressure sequences when the secondary side is failed. If the break size is too small to sufficiently decrease the RCS pressure, the F-B operation is necessary. Therefore, in the case of a combined accident including a secondary cooling system failure, the provision of clear information will play a critical role in the operators' decision to initiate an F-B operation. This study focuses on the how we establish the operation strategy for combined accident including the failure of secondary side in consideration of plant and operating conditions. Previous studies have usually focused on accidents involving a TLOFW accident. The plant conditions to make the operators confused seriously are usually the combined accident because the ORP only focuses on a single accident and FRP is less familiar with operators. The relationship between CET and PCT under various plant conditions is important to decide the limitation of initiating the F-B operation to prevent core damage

  4. Micro-fabricated all optical pressure sensors

    DEFF Research Database (Denmark)

    Havreland, Andreas Spandet; Petersen, Søren Dahl; Østergaard, Christian

    2017-01-01

    Optical pressure sensors can operate in certain harsh application areas where the electrical pressure sensors cannot. However, the sensitivity is often not as good for the optical sensors. This work presents an all optical pressure sensor, which is fabricated by micro fabrication techniques, where...... the sensitivity can be tuned in the fabrication process. The developed sensor design, simplifies the fabrication process leading to a lower fabrication cost, which can make the all optical pressure sensors more competitive towards their electrical counterpart. The sensor has shown promising results and a linear...... pressure response has been measured with a sensitivity of 0.6nm/bar....

  5. RF emission-based health monitoring for hybrid and/or all electric aircraft distributed propulsion systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Future aircraft propulsion is destined to be electric. All electric aircraft propulsion systems promise significant improvements in energy efficiency,...

  6. Electric Vehicle Sharing Planning and Operations

    Science.gov (United States)

    2018-02-01

    Dongfang Zhao (ORCID ID 0000-0002-5424-9915); Xiaopeng (Shaw) Li (ORCID ID 0000-0002-5264-3775); Yu Zhang (ORCID ID 0000-0003-1202-626X) This project includes literature review and proposing a model for EV planning and operations. We first conducted ...

  7. Field Operations Program Neighborhood Electric Vehicles - Fleet Survey

    Energy Technology Data Exchange (ETDEWEB)

    Francfort, James Edward; Carroll, M.

    2001-07-01

    This report summarizes a study of 15 automotive fleets that operate neighborhood electric vehicles(NEVs) in the United States. The information was obtained to help Field Operations Program personnel understand how NEVs are being used, how many miles they are being driven, and if they are being used to replace other types of fleet vehicles or as additions to fleets. (The Field Operations Program is a U.S. Department of Energy Program within the DOE Office of Energy Efficiency and Renewable Energy, Transportation Technologies). The NEVs contribution to petroleum avoidance and cleaner air can be estimated based on the miles driven and by assuming gasoline use and air emissions values for the vehicles being replaced. Gasoline and emissions data for a Honda Civic are used as the Civic has the best fuel use for a gasoline-powered vehicle and very clean emissions. Based on these conservation assumptions, the 348 NEVs are being driven a total of about 1.2 million miles per year. This equates to an average of 3,409 miles per NEV annually or 9 miles per day. It is estimated that 29,195 gallons of petroleum use is avoided annually by the 348 NEVs. This equates to 87 gallons of petroleum use avoided per NEV, per year. Using the 348 NEVs avoids the generation of at least 775 pounds of smog- forming emissions annually.

  8. Field Operations Program - Neighborhood Electric Vehicle Fleet Use

    Energy Technology Data Exchange (ETDEWEB)

    Francfort, J. E.; Carroll, M. R.

    2001-07-02

    This report summarizes a study of 15 automotive fleets that operate neighborhood electric vehicles (NEVs) in the United States. The information was obtained to help Field Operations Program personnel understand how NEVs are being used, how many miles they are being driven, and if they are being used to replace other types of fleet vehicles or as additions to fleets. (The Field Operations Program is a U.S. Department of Energy Program within the DOE Office of Energy Efficiency and Renewable Energy, Transportation Technologies). The NEVs contribution to petroleum avoidance and cleaner air can be estimated based on the miles driven and by assuming gasoline use and air emissions values for the vehicles being replaced. Gasoline and emissions data for a Honda Civic are used as the Civic has the best fuel use for a gasoline-powered vehicle and very clean emissions. Based on these conservation assumptions, the 348 NEVs are being driven a total of about 1.2 million miles per year. This equates to an average of 3,409 miles per NEV annually or 9 miles per day. It is estimated that 29,195 gallons of petroleum use is avoided annually by the 348 NEVs. This equates to 87 gallons of petroleum use avoided per NEV, per year. Using the 348 NEVs avoids the generation of at least 775 pounds of smog-forming emissions annually.

  9. A globally nonsingular quaternion-based formulation for all-electric satellite trajectory optimization

    Science.gov (United States)

    Libraro, Paola

    The general electric propulsion orbit-raising maneuver of a spacecraft must contend with four main limiting factors: the longer time of flight, multiple eclipses prohibiting continuous thrusting, long exposure to radiation from the Van Allen belt and high power requirement of the electric engines. In order to optimize a low-thrust transfer with respect to these challenges, the choice of coordinates and corresponding equations of motion used to describe the kinematical and dynamical behavior of the satellite is of critical importance. This choice can potentially affect the numerical optimization process as well as limit the set of mission scenarios that can be investigated. To increase the ability to determine the feasible set of mission scenarios able to address the challenges of an all-electric orbit-raising, a set of equations free of any singularities is required to consider a completely arbitrary injection orbit. For this purpose a new quaternion-based formulation of a spacecraft translational dynamics that is globally nonsingular has been developed. The minimum-time low-thrust problem has been solved using the new set of equations of motion inside a direct optimization scheme in order to investigate optimal low-thrust trajectories over the full range of injection orbit inclinations between 0 and 90 degrees with particular focus on high-inclinations. The numerical results consider a specific mission scenario in order to analyze three key aspects of the problem: the effect of the initial guess on the shape and duration of the transfer, the effect of Earth oblateness on transfer time and the role played by, radiation damage and power degradation in all-electric minimum-time transfers. Finally trade-offs between mass and cost savings are introduced through a test case.

  10. Use of SP-100 thermometry technology to improve operation of electric power plants

    International Nuclear Information System (INIS)

    Shepard, R.L.

    1996-01-01

    Control of the nuclear power source for the SP-100 electric power supply required a thermometer that would be 1% accurate at temperatures to 1,100 C with no drift and unattended operation for more than 7 years in moderate radiation environment. Johnson noise thermometers had been developed by Oak Ridge National Laboratory originally for nuclear fuel centerline temperature measurements were believed to be able to provide this performance. They were then adapted for use in the SP-100. This Johnson noise technology also has direct application to two problems in the electric power plant: in situ calibration of conventional resistance thermometers installed in steam systems at temperatures up to about 560 C and measurement of combustion chamber temperatures up to bout 1,100 C. Both capacities require measurement of Johnson noise in harsh industrial environments. The final development and transfer of the SP-100 technology to the electric power sector is currently being supported by the Electric Power Research Institute (EPRI)

  11. Novel electrical energy storage system based on reversible solid oxide cells: System design and operating conditions

    Science.gov (United States)

    Wendel, C. H.; Kazempoor, P.; Braun, R. J.

    2015-02-01

    Electrical energy storage (EES) is an important component of the future electric grid. Given that no other widely available technology meets all the EES requirements, reversible (or regenerative) solid oxide cells (ReSOCs) working in both fuel cell (power producing) and electrolysis (fuel producing) modes are envisioned as a technology capable of providing highly efficient and cost-effective EES. However, there are still many challenges and questions from cell materials development to system level operation of ReSOCs that should be addressed before widespread application. This paper presents a novel system based on ReSOCs that employ a thermal management strategy of promoting exothermic methanation within the ReSOC cell-stack to provide thermal energy for the endothermic steam/CO2 electrolysis reactions during charging mode (fuel producing). This approach also serves to enhance the energy density of the stored gases. Modeling and parametric analysis of an energy storage concept is performed using a physically based ReSOC stack model coupled with thermodynamic system component models. Results indicate that roundtrip efficiencies greater than 70% can be achieved at intermediate stack temperature (680 °C) and elevated stack pressure (20 bar). The optimal operating condition arises from a tradeoff between stack efficiency and auxiliary power requirements from balance of plant hardware.

  12. A flexible control strategy of plug-in electric vehicles operating in seven modes for smoothing load power curves in smart grid

    International Nuclear Information System (INIS)

    Khemakhem, Siwar; Rekik, Mouna; Krichen, Lotfi

    2017-01-01

    Plug-in electric vehicles (PEVs) seem to be an interesting new electrical load for improving the reliability of smart grid. The purpose of this work is to investigate a supervision strategy based on regulated charging of PEVs in order to guarantee an optimized power management of the system and consequently a flatter power demand curve. The system mainly includes PEVs powered by a Lithium-ion battery ensuring the charging and discharging operations of these PEVs at home and a daily load power demanded by home appliances. The purpose of the considered strategy is to detect the connection status of each PEV and to establish the priority order between these PEVs with certain flexibility which results in managing the PEVs through seven operating modes. The response of the control algorithm enables to ensure the power flow exchange between the PEVs and the electrical grid, especially at rush hours, and to minimize load power variance aiming to achieve the smoothness for the power demand curve and to reduce the stress of the electrical grid. The simulation results are presented in order to illustrate the efficiency of this power control approach. - Highlights: • A flexible power management algorithm of Plug-in electric vehicle is proposed. • This control can be applied for any home equipped with two PEVs. • The response is to ensure the power flow exchange between PEVs and power grid. • The main contribution is to achieve the smoothness for the daily power demand curve.

  13. NRC Information No. 87-24: Operational experience involving losses of electrical inverters

    International Nuclear Information System (INIS)

    Rossi, C.E.

    1992-01-01

    The NRC case study report identified three potential failure mechanisms for inverters. One of these involves relatively high ambient temperature and/or humidity within inverter enclosures. This condition appears to result in accelerated aging of components that form a part of the inverter circuitry causing a significant reduction in component life expectancy and inverter loss. Another mechanism for inverter failure involves the electrical interconnecting and physical arrangements for the inverter circuitry components. In some installations, these arrangements are such that when certain components fail, other components also may fail or degrade. The third failure mechanism involves voltage spikes and perturbations. Many of the electrical loads in a plant have inductive characteristics. During plant operations that involve energizing and deenergizing these loads, voltage spikes and perturbations are generated. The solid-state devices in the inverter circuitry are sensitive to these voltage spikes, and this has resulted in component failure, blown fuses, and inverter losses. Additionally, secondary voltage perturbations caused by lighting strikes or switching surges can have an adverse effect on inverter operation

  14. Electricity storages - optimised operation based on spot market prices; Stromspeicher. Optimierte Fahrweise auf Basis der Spotmarktpreise

    Energy Technology Data Exchange (ETDEWEB)

    Bernhard, Dominik; Roon, Serafin von [FfE Forschungsstelle fuer Energiewirtschaft e.V., Muenchen (Germany)

    2010-06-15

    With its integrated energy and climate package the last federal government set itself ambitious goals for the improvement of energy efficiency and growth of renewable energy production. These goals were confirmed by the new government in its coalition agreement. However, they can only be realised if the supply of electricity from fluctuating renewable sources can be made to coincide with electricity demand. Electricity storages are therefore an indispensable component of the future energy supply system. This article studies the optimised operation of an electricity storage based on spot market prices and the influence of wind power production up to the year 2020.

  15. Analysis of Surface Electric Field Measurements from an Array of Electric Field Mills

    Science.gov (United States)

    Lucas, G.; Thayer, J. P.; Deierling, W.

    2016-12-01

    Kennedy Space Center (KSC) has operated an distributed array of over 30 electric field mills over the past 18 years, providing a unique data set of surface electric field measurements over a very long timespan. In addition to the electric field instruments there are many meteorological towers around KSC that monitor the local meteorological conditions. Utilizing these datasets we have investigated and found unique spatial and temporal signatures in the electric field data that are attributed to local meteorological effects and the global electric circuit. The local and global scale influences on the atmospheric electric field will be discussed including the generation of space charge from the ocean surf, local cloud cover, and a local enhancement in the electric field that is seen at sunrise.

  16. Preoperative Scale to Determine All-Cause Readmission After Coronary Artery Bypass Operations.

    Science.gov (United States)

    Zywot, Aleksander; Lau, Christine S M; Glass, Nina; Bonne, Stephanie; Hwang, Franchesca; Goodman, Koren; Mosenthal, Anne; Paul, Subroto

    2018-04-01

    Coronary artery bypass graft (CABG) operations are associated with all-cause readmission rates of approximately 15%. In attempts to reduce readmission rates, the Hospital Readmission Reduction Program expanded to include CABG operations in 2015. The aim of this study was therefore to develop a predictive readmission scale that would identify patients at higher risk of readmission after CABG using commonly available administrative data. Data of 126,519 patients from California and New York (derivation cohort) and 94,318 patients from Florida and Washington (validation cohort) were abstracted from the State Inpatient Database (2006 to 2011). The readmission after CABG scale was developed to predict 30-day readmission risk and was validated against a separate cohort. Thirty-day CABG readmission rates were 23% in the derivation cohort and 21% in the validation cohort. Predictive factors included older age, female gender (odds ratio [OR], 1.34), African American ethnicity (OR, 1.13), Medicare or Medicaid insurance, and comorbidities, including renal failure (OR, 1.56) and congestive heart failure (OR, 2.82). These were independently predictive of increased readmission rates (p readmission scale was then created with these preoperative factors. When applied to the validation cohort, it explained 98% of the readmission variability. The readmission after CABG scale reliably predicts a patient's 30-day CABG readmission risk. By identifying patients at high-risk for readmission before their procedure, risk reduction strategies can be implemented to reduce readmissions and healthcare expenditures. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Can rural electric cooperatives survive in a restructured US electric market? An empirical analysis

    International Nuclear Information System (INIS)

    Greer, Monica Lynne

    2003-01-01

    This paper examines the ability of rural electric distribution cooperatives to continue operating in their present form in a restructured electricity market. More specifically, I develop and estimate a quadratic cost model, which, unlike many of the cost functions employed in studies of this nature, conforms to all of the properties of a proper cost function. Using 1996 data, I find that these firms are not operating in a cost-minimizing fashion. This finding seems to occur because each is too small in terms of the quantity of electricity distributed. As a result, mergers between these firms could yield substantial savings and help ensure their survival in their present form in a deregulated market

  18. Modeling the dynamic and thermodynamic operation of Stirling engines by means of an equivalent electrical circuit

    International Nuclear Information System (INIS)

    Cascella, Franco; Sorin, Mikhail; Formosa, Fabien; Teyssedou, Alberto

    2017-01-01

    Highlights: • A model based on the electrical analogy theory has been developed to predict the operation of a Stirling engine. • The models takes into account the continuity, the momentum and the energy conservation equations. • The model predicts the operating conditions of the RE100 Free piston Stirling engine. • The model is sensible to the modeling of the effects of the machine load. - Abstract: The Stirling engines are inherently efficient; their thermodynamic cycles reach the Carnot efficiency. These technologies are suitable to operate under any low temperature difference between the hot and the cold sources. For these reasons, these engines can be considered as reliable power conversion systems to promote the conversion of low-grade waste heat generated by industrial plants. The need of a model to predict the behavior of these engines is of primary importance. Nevertheless, a great difficulty is encountered in developing such a model since it is not simple to take into account coupled thermodynamic and dynamic effects. This is the main reason why several models make use of electrical analogies to describe Stirling engines (in particular, free-piston machines): by assuming the pressure equivalent to a voltage and the flow rate to an electrical current, a coupled dynamic-thermodynamic analysis of the engine can be performed. In this paper, an electrical circuit whose behavior is equivalent to that of the engine is derived from the electrical analogy theory. To this aim, we propose an electrical analogy model based on the three conservation laws (mass, momentum and energy). Since limited experimental information is available in the open literature, the results obtained with the proposed model are compared with the experimental data collected at the NASA Lewis Research center for a free-piston Stirling engine i.e., the RE-1000 engine.

  19. Report for 2008 on electricity and natural-gas network operators: obedience to compliance programmes and independence. Report 2008

    International Nuclear Information System (INIS)

    2008-12-01

    In France, system operators belong to groups that also conduct business in the energy sector, in fields governed by competition rules. They could therefore be tempted to use their privileged position to their group's benefit, which would disadvantage end consumers. Non-discriminatory access to electricity and gas transmission and distribution networks is at the core of the market opening to competition approach implemented by the European Union since the end of the 1990's. EU and national enactments in force highlight two tools to ensure nondiscrimination: compliance programmes and independence of system operators with regard to their parent companies. Firstly, compliance programs contain measures taken to ensure that discrimination is completely excluded and that their application is subject to appropriate monitoring. Secondly, system operator independence plays a part in preventing discrimination against competitors with other business activities (generation, supply, etc.) within the same group. In application of these enactments, every electricity or natural gas transmission or distribution system operator serving more than 100,000 customers provided CRE, the Energy Regulatory Commission, with their annual reports on the application of their compliance programs. This document is CRE's 2008 report about compliance programmes and independence of electricity and natural gas system operators. Contents: 1 - Obedience to compliance programmes: Assessment compared with 2007, Demands from CRE; 2 - The independence of system operators: Transmission system operators, Distribution system operators, Comments common to both transmission and distribution system operators

  20. Electrical transformer handbook

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, R.W.; Horne, D. (eds.)

    2005-07-01

    This handbook is a valuable user guide intended for electrical engineering and maintenance personnel, electrical contractors and electrical engineering students. It provides current information on techniques and technologies that can help extend the life of transformers. It discusses transformer testing, monitoring, design, commissioning, retrofitting and other elements involved in keeping electrical transformers in safe and efficient operation. It demonstrates how a power transformer can be put to use and common problems faced by owners. In addition to covering control techniques, testing and maintenance procedures, this handbook covers the power transformer; control electrical power transformer; electrical power transformer; electrical theory transformer; used electrical transformer; down electrical step transformer; electrical manufacturer transformer; electrical picture transformer; electrical transformer work; electrical surplus transformer; current transformer; step down transformer; voltage transformer; step up transformer; isolation transformer; low voltage transformer; toroidal transformer; high voltage transformer; and control power transformer. The handbook includes articles from leading experts on overcurrent protection of transformers; ventilated dry-type transformers; metered load factors for low-voltage, and dry-type transformers in buildings. The maintenance of both dry-type or oil-filled transformers was discussed with reference to sealing, gaskets, oils, moisture and testing. The adoption of dynamic load practices was also discussed along with the reclamation or recycling of used lube oil, transformer dielectric fluids and aged solid insulation. A buyer's guide and directory of transformer manufacturers and suppliers was also included. refs., tabs., figs.

  1. Modeling and Analyzing Electric Vehicle Charging

    DEFF Research Database (Denmark)

    Andersen, Ove; Krogh, Benjamin Bjerre; Thomsen, Christian

    2016-01-01

    , such as wind turbines. To both enable a smart grid and the use of renewable energy, it is essential to know when and where an EV is plugged into the power grid and what battery capacity is available. In this paper, we present a generic spatio-temporal data-warehouse model for storing detailed information...... on all aspects of charging EVs, including integration with the electricity prices from a spot market. The proposed data warehouse is fully implemented and currently contains 2.5 years of charging data from 176 EVs. We describe the date warehouse model and the implementation including complex operations...

  2. Fuel Cell Electric Vehicle Evaluations | Hydrogen and Fuel Cells | NREL

    Science.gov (United States)

    Electric Vehicle Evaluations Fuel Cell Electric Vehicle Evaluations NREL's technology validation team analyzes hydrogen fuel cell electric vehicles (FCEVs) operating in a real-world setting to include commercial FCEVs for the first time. Current fuel cell electric vehicle evaluations build on the

  3. Direct participation of electrical loads in the California independent system operator markets during the Summer of 2000

    International Nuclear Information System (INIS)

    Marnay, Chris; Hamachi, Kristina S.; Khavkin, Mark; Siddiqui, Afzal S.

    2001-01-01

    California's restructured electricity markets opened on 1 April 1998. The former investor-owned utilities were functionally divided into generation, transmission, and distribution activities, all of their gas-fired generating capacity was divested, and the retail market was opened to competition. To ensure that small customers shared in the expected benefit of lower prices, the enabling legislation mandated a 10% rate cut for all customers, which was implemented in a simplistic way that fossilized 1996 tariff structures. Rising fuel and environmental compliance costs, together with a reduced ability to import electricity, numerous plant outages, and exercise of market power by generators drove up wholesale electricity prices steeply in 2000, while retail tariffs remained unchanged. One of the distribution/supply companies entered bankruptcy in April 2001, and another was insolvent. During this period, two sets of interruptible load programs were in place, longstanding ones organized as special tariffs by the distribution/supply companies and hastily established ones run directly by the California Independent System Operator (CAISO). The distribution/supply company programs were effective at reducing load during the summer of 2000, but because of the high frequency of outages required by a system on the brink of failure, customer response declined and many left the tariff. The CAISO programs failed to attract enough participation to make a significant difference to the California supply demand imbalance. The poor performance of direct load participation in California's markets reinforces the argument for accurate pricing of electricity as a stimulus to energy efficiency investment and as a constraint on market volatility

  4. Motor-operated gearbox efficiency

    International Nuclear Information System (INIS)

    DeWall, K.G.; Watkins, J.C.; Bramwell, D.; Weidenhamer, G.H.

    1996-01-01

    Researchers at the Idaho National Engineering Laboratory recently conducted tests investigating the operating efficiency of the power train (gearbox) in motor-operators typically used in nuclear power plants to power motor-operated valves. Actual efficiency ratios were determined from in-line measurements of electric motor torque (input to the operator gearbox) and valve stem torque (output from the gearbox) while the operators were subjected to gradually increasing loads until the electric motor stalled. The testing included parametric studies under reduced voltage and elevated temperature conditions. As part of the analysis of the results, the authors compared efficiency values determined from testing to the values published by the operator manufacturer and typically used by the industry in calculations for estimating motor-operator capabilities. The operators they tested under load ran at efficiencies lower than the running efficiency (typically 50%) published by the operator manufacturer

  5. Motor-operated gearbox efficiency

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States); Weidenhamer, G.H.

    1996-12-01

    Researchers at the Idaho National Engineering Laboratory recently conducted tests investigating the operating efficiency of the power train (gearbox) in motor-operators typically used in nuclear power plants to power motor-operated valves. Actual efficiency ratios were determined from in-line measurements of electric motor torque (input to the operator gearbox) and valve stem torque (output from the gearbox) while the operators were subjected to gradually increasing loads until the electric motor stalled. The testing included parametric studies under reduced voltage and elevated temperature conditions. As part of the analysis of the results, the authors compared efficiency values determined from testing to the values published by the operator manufacturer and typically used by the industry in calculations for estimating motor-operator capabilities. The operators they tested under load ran at efficiencies lower than the running efficiency (typically 50%) published by the operator manufacturer.

  6. Motor-operator gearbox efficiency

    International Nuclear Information System (INIS)

    DeWall, K.G.; Watkins, J.C.; Bramwell, D.

    1996-01-01

    Researchers at the Idaho National Engineering Laboratory recently conducted tests investigating the operating efficiency of the power train (gearbox) in motor-operators typically used in nuclear power plants to power motor-operated valves. Actual efficiency ratios were determined from in-line measurements of electric motor torque (input to the operator gearbox) and valve stem torque (output from the gearbox) while the operators were subjected to gradually increasing loads until the electric motor stalled. The testing included parametric studies under reduced voltage and elevated temperature conditions. As part of the analysis of the results, we compared efficiency values determined from testing to the values published by the operator manufacturer and typically used by the industry in calculations for estimating motor-operator capabilities. The operators we tested under load ran at efficiencies lower than the running efficiency (typically 50%) published by the operator manufacturer

  7. RoboCon: Operator interface for robotic applications. Final report: RoboCon electrical interfacing -- system architecture, and Interfacing NDDS and LabView

    Energy Technology Data Exchange (ETDEWEB)

    Schempf, H.

    1998-04-30

    The first appendix contains detailed specifications of the electrical interfacing employed in Robocon. This includes all electrical signals and power requirement descriptions up to and including the interface entry points for external robots and systems. The reader is first presented with an overview of the overall Robocon electrical system, followed by sub-sections describing each module in detail. The appendices contain listings of power requirements and the electrical connectors and cables used, followed by an overall electrical system diagram. Custom electronics employed are also described. The Network Data Delivery Service (NDDS) is a real-time dissemination communications architecture which allows nodes on a network to publish data and subscribe to data published by other nodes while remaining anonymous. The second appendix explains how to facilitate a seamless interface between NDDS and LabView and provides sample source code used to implement an NDDS consumer which writes a string to a socket.

  8. Nanomechanical electric and electromagnetic field sensor

    Science.gov (United States)

    Datskos, Panagiotis George; Lavrik, Nickolay

    2015-03-24

    The present invention provides a system for detecting and analyzing at least one of an electric field and an electromagnetic field. The system includes a micro/nanomechanical oscillator which oscillates in the presence of at least one of the electric field and the electromagnetic field. The micro/nanomechanical oscillator includes a dense array of cantilevers mounted to a substrate. A charge localized on a tip of each cantilever interacts with and oscillates in the presence of the electric and/or electromagnetic field. The system further includes a subsystem for recording the movement of the cantilever to extract information from the electric and/or electromagnetic field. The system further includes a means of adjusting a stiffness of the cantilever to heterodyne tune an operating frequency of the system over a frequency range.

  9. Operating health analysis of electric power systems

    Science.gov (United States)

    Fotuhi-Firuzabad, Mahmud

    The required level of operating reserve to be maintained by an electric power system can be determined using both deterministic and probabilistic techniques. Despite the obvious disadvantages of deterministic approaches there is still considerable reluctance to apply probabilistic techniques due to the difficulty of interpreting a single numerical risk index and the lack of sufficient information provided by a single index. A practical way to overcome difficulties is to embed deterministic considerations in the probabilistic indices in order to monitor the system well-being. The system well-being can be designated as healthy, marginal and at risk. The concept of system well-being is examined and extended in this thesis to cover the overall area of operating reserve assessment. Operating reserve evaluation involves the two distinctly different aspects of unit commitment and the dispatch of the committed units. Unit commitment health analysis involves the determination of which unit should be committed to satisfy the operating criteria. The concepts developed for unit commitment health, margin and risk are extended in this thesis to evaluate the response well-being of a generating system. A procedure is presented to determine the optimum dispatch of the committed units to satisfy the response criteria. The impact on the response wellbeing being of variations in the margin time, required regulating margin and load forecast uncertainty are illustrated. The effects on the response well-being of rapid start units, interruptible loads and postponable outages are also illustrated. System well-being is, in general, greatly improved by interconnection with other power systems. The well-being concepts are extended to evaluate the spinning reserve requirements in interconnected systems. The interconnected system unit commitment problem is decomposed into two subproblems in which unit scheduling is performed in each isolated system followed by interconnected system evaluation

  10. Decomposing climate-induced temperature and water effects on the expansion and operation of the US electricity system

    Science.gov (United States)

    Sun, Y.; Eurek, K.; Macknick, J.; Steinberg, D. C.; Averyt, K.; Badger, A.; Livneh, B.

    2017-12-01

    Climate change has the potential to affect the supply and demands of the U.S. power sector. Rising air temperatures can affect the seasonal and total demand for electricity, alter the thermal efficiency of power plants, and lower the maximum capacity of electric transmission lines. Changes in hydrology can affect seasonal and total availability of water used for power plant operations. Prior studies have examined some climate impacts on the electricity sector, but there has been no systematic study quantifying and comparing the importance of these climate-induced effects in isolation and in combination. Here, we perform a systematic assessment using the Regional Energy Deployment System (ReEDS) electricity sector model in combination with downscaled climate results from four models in the CMIP5 archive that provide contrasting temperature and precipitation trends for key regions in the U.S. The ReEDS model captures dynamic climate and hydrological resource data .when choosing the cost optimal mix of generation resources necessary to balance supply and demand for electricity. We examine how different climate-induced changes in air temperature and water availability, considered in isolation and in combination, may affect energy and economic outcomes at a regional and national level from the present through 2050. Results indicate that temperature-induced impacts on electricity consumption show consistent trends nationwide across all climate scenarios. Hydrological impacts and variability differ by model and tend to have a minor effect on national electricity trends, but can be important determinants regionally. Taken together, this suggests that isolated climate change impacts on the electricity system depend on the geographic scale of interest - the effect of rising temperatures on demand, which is qualitatively robust to the choice of climate model, largely determines impacts on generation, capacity and cost at the national level, whereas other impact pathways may

  11. 29 CFR 784.108 - Operations not included in named operations on forms of aquatic “life.”

    Science.gov (United States)

    2010-07-01

    ... subject matter of the exemptions is concerned with “aquatic forms of animal and vegetable life,” the..., novelties, liquid glue, isinglass, pearl essence, and fortified or refined fish oil is not within these... 29 Labor 3 2010-07-01 2010-07-01 false Operations not included in named operations on forms of...

  12. Voltage- and current-activated metal–insulator transition in VO2-based electrical switches: a lifetime operation analysis

    Directory of Open Access Journals (Sweden)

    Aurelian Crunteanu, Julien Givernaud, Jonathan Leroy, David Mardivirin, Corinne Champeaux, Jean-Christophe Orlianges, Alain Catherinot and Pierre Blondy

    2010-01-01

    Full Text Available Vanadium dioxide is an intensively studied material that undergoes a temperature-induced metal–insulator phase transition accompanied by a large change in electrical resistivity. Electrical switches based on this material show promising properties in terms of speed and broadband operation. The exploration of the failure behavior and reliability of such devices is very important in view of their integration in practical electronic circuits. We performed systematic lifetime investigations of two-terminal switches based on the electrical activation of the metal–insulator transition in VO2 thin films. The devices were integrated in coplanar microwave waveguides (CPWs in series configuration. We detected the evolution of a 10 GHz microwave signal transmitted through the CPW, modulated by the activation of the VO2 switches in both voltage- and current-controlled modes. We demonstrated enhanced lifetime operation of current-controlled VO2-based switching (more than 260 million cycles without failure compared with the voltage-activated mode (breakdown at around 16 million activation cycles. The evolution of the electrical self-oscillations of a VO2-based switch induced in the current-operated mode is a subtle indicator of the material properties modification and can be used to monitor its behavior under various external stresses in sensor applications.

  13. Electric power substations engineering

    CERN Document Server

    McDonald, John D

    2012-01-01

    The use of electric power substations in generation, transmission, and distribution remains one of the most challenging and exciting areas of electric power engineering. Recent technological developments have had a tremendous impact on all aspects of substation design and operation. With 80% of its chapters completely revised and two brand-new chapters on energy storage and Smart Grids, Electric Power Substations Engineering, Third Edition provides an extensive updated overview of substations, serving as a reference and guide for both industry and academia. Contributors have written each chapt

  14. INNOVATIVE HYBRID GAS/ELECTRIC CHILLER COGENERATION

    Energy Technology Data Exchange (ETDEWEB)

    Todd Kollross; Mike Connolly

    2004-06-30

    Engine-driven chillers are quickly gaining popularity in the market place (increased from 7,000 tons in 1994 to greater than 50,000 tons in 1998) due to their high efficiency, electric peak shaving capability, and overall low operating cost. The product offers attractive economics (5 year pay back or less) in many applications, based on areas cooling requirements and electric pricing structure. When heat is recovered and utilized from the engine, the energy resource efficiency of a natural gas engine-driven chiller is higher than all competing products. As deregulation proceeds, real time pricing rate structures promise high peak demand electric rates, but low off-peak electric rates. An emerging trend with commercial building owners and managers who require air conditioning today is to reduce their operating costs by installing hybrid chiller systems that combine gas and electric units. Hybrid systems not only reduce peak electric demand charges, but also allow customers to level their energy load profiles and select the most economical energy source, gas or electricity, from hour to hour. Until recently, however, all hybrid systems incorporated one or more gas-powered chillers (engine driven and/or absorption) and one or more conventional electric units. Typically, the cooling capacity of hybrid chiller plants ranges from the hundreds to thousands of refrigeration tons, with multiple chillers affording the user a choice of cooling systems. But this flexibility is less of an option for building operators who have limited room for equipment. To address this technology gap, a hybrid chiller was developed by Alturdyne that combines a gas engine, an electric motor and a refrigeration compressor within a single package. However, this product had not been designed to realize the full features and benefits possible by combining an engine, motor/generator and compressor. The purpose of this project is to develop a new hybrid chiller that can (1) reduce end-user energy

  15. The nuclear electricity generating industry in England and Wales post-privatisation

    International Nuclear Information System (INIS)

    Johnson, C.B.

    1992-01-01

    This paper presents an overview of the new legal framework within which the nuclear generating industry has operated in England and Wales since 31 March 1990. It describes the formation of Nuclear Electric plc and the licensing arrangements, including the various obligations which have been placed upon Nuclear Electric by virtue of its Generation Licence. The impact of competition law is outlined, together with the commercial arrangements including electricity pooling and some of the other more important agreements which Nuclear Electric has entered into. Finally, the Paper discusses some of the constraints under which Nuclear Electric operates, and summarises Government policy towards nuclear power and its future prospects in the United Kingdom. (author)

  16. Economic assessment and optimal operation of CSP systems with TES in California electricity markets

    Science.gov (United States)

    Dowling, Alexander W.; Dyreson, Ana; Miller, Franklin; Zavala, Victor M.

    2017-06-01

    The economics and performance of concentrated power (CSP) systems with thermal energy storage (TES) inherently depend on operating policies and the surrounding weather conditions and electricity markets. We present an integrated economic assessment framework to quantify the maximum possible revenues from simultaneous energy and ancillary services sales by CSP systems. The framework includes both discrete start-up/shutdown restrictions and detailed physical models. Analysis of coinci-dental historical market and meteorological data reveals provision of ancillary services increases market revenue 18% to 37% relative to energy-only participation. Surprisingly, only 53% to 62% of these revenues are available through sole participation in the day-ahead market, indicating significant opportunities at faster timescales. Motivated by water-usage concerns and permitting requirements, we also describe a new nighttime radiative-enhanced dry-cooling system with cold-side storage that consumes no water and offers higher effciencies than traditional air-cooled designs. Operation of this new system is complicated by the cold-side storage and inherent coupling between the cooling system and power plant, further motivating integrated economic analysis.

  17. The role of the European Union in private law relations of organizations operating in the internal electricity or gas market in medium and small size Member States

    International Nuclear Information System (INIS)

    Nechvátal, Ivan; Pilavachi, Petros A.; Kakaras, Emmanuel

    2012-01-01

    This paper studies European Union (EU) legislation on private law relations for organizations operating in the internal electricity and gas market in medium and small size Member States. It consists of the analysis of both the EU primary (Treaties) and secondary (directives and regulations) legislation. A survey was sent to organizations operating in the internal energy market in four Member States: Greece, Czech Republic, Finland, and Malta. Through the survey, the paper identifies problematic areas of current EU legislation and compares them with new legislation applied as from 3 March 2011 (third liberalization package). It looks into all important EU energy legislation on private law relations of organizations operating in the internal energy market such as unbundling, procurement, procedural law, duties related to information and other legislation on energy contracts. The study concludes that, despite some small problems, the energy liberalization including the third liberalization legislative package progresses in a correct manner. There are nearly no problems in the access to the transmission and distribution systems. The functioning of the gas market is considered as the most important problem. - Highlights: ► European Union legislation on private law relations was studied. ► Organizations operating in the electricity and gas market were considered. ► A survey was sent to organizations in four Member States. ► Despite some problems, the energy liberalization advances correctly. ► The gas market is considered as the most important problem.

  18. Theory, design, and operation of liquid metal fast breeder reactors, including operational health physics

    International Nuclear Information System (INIS)

    Adams, S.R.

    1985-10-01

    A comprehensive evaluation was conducted of the radiation protection practices and programs at prototype LMFBRs with long operational experience. Installations evaluated were the Fast Flux Test Facility (FFTF), Richland, Washington; Experimental Breeder Reactor II (EBR-II), Idaho Falls, Idaho; Prototype Fast Reactor (PFR) Dounreay, Scotland; Phenix, Marcoule, France; and Kompakte Natriumgekuhlte Kernreak Toranlange (KNK II), Karlsruhe, Federal Republic of Germany. The evaluation included external and internal exposure control, respiratory protection procedures, radiation surveillance practices, radioactive waste management, and engineering controls for confining radiation contamination. The theory, design, and operating experience at LMFBRs is described. Aspects of LMFBR health physics different from the LWR experience in the United States are identified. Suggestions are made for modifications to the NRC Standard Review Plan based on the differences

  19. Theory, design, and operation of liquid metal fast breeder reactors, including operational health physics

    Energy Technology Data Exchange (ETDEWEB)

    Adams, S.R.

    1985-10-01

    A comprehensive evaluation was conducted of the radiation protection practices and programs at prototype LMFBRs with long operational experience. Installations evaluated were the Fast Flux Test Facility (FFTF), Richland, Washington; Experimental Breeder Reactor II (EBR-II), Idaho Falls, Idaho; Prototype Fast Reactor (PFR) Dounreay, Scotland; Phenix, Marcoule, France; and Kompakte Natriumgekuhlte Kernreak Toranlange (KNK II), Karlsruhe, Federal Republic of Germany. The evaluation included external and internal exposure control, respiratory protection procedures, radiation surveillance practices, radioactive waste management, and engineering controls for confining radiation contamination. The theory, design, and operating experience at LMFBRs is described. Aspects of LMFBR health physics different from the LWR experience in the United States are identified. Suggestions are made for modifications to the NRC Standard Review Plan based on the differences.

  20. A win-win marginal rent analysis for operator and consumer under battery leasing mode in China electric vehicle market

    International Nuclear Information System (INIS)

    Li Zhe; Ouyang Minggao

    2011-01-01

    Recently battery leasing has been introduced into the market by automobile manufacturers and power suppliers due to its potential to reduce the purchase cost of electric vehicles (EVs). However, the profit prospect of battery leasing is still uncertain. This paper takes the views of both the operators and consumers and calculates the 'win-win' marginal rent, which not only ensures the profitability of operators, but also allows consumers a lower expenditure than using Internal combustion engine vehicles (ICVs) and EVs with embedded batteries. Battery cost, vehicle weight, gasoline and electricity price, and the discount rate have impacts on the rent. Battery cost plays a dominant role and a battery cost >5 Yen /W h fails to enable the survival of battery leasing to all types of EVs. Battery leasing would be more competitive when focusing on heavier EVs. At least one of the three thresholds is required for the existence of rent pricing range for a 1000 kg EV: gasoline retail price >6 Yen /L, electricity price <0.6 Yen /kW h, or the discount rate <7%. Typically, the feasible battery rent range is 0.34-0.38 Yen /W h/year for a 1000 kg EV under the present battery cost 2 Yen /W h and China current gasoline and electricity prices. - Highlights: → Rent pricing for EV battery leasing must obey win-win rule for BLO and consumers. → Rent is affected by battery cost, vehicle weight, energy price and discount rate. → Battery cost plays dominant role for the BLO survival as described in '5-3-2' Law. → Heavier EVs are more suitable for battery leasing when battery cost is high. → The profitability of BLO is sensitive to the price of gasoline and electricity.

  1. Results from the Operational Testing of the Eaton Smart Grid Capable Electric Vehicle Supply Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, Brion [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-10-01

    The Idaho National Laboratory conducted testing and analysis of the Eaton smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from Eaton for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the Eaton smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

  2. Distributed control in the electricity infrastructure

    International Nuclear Information System (INIS)

    Kok, J.K.; Warmer, C.; Kamphuis, I.G.; Mellstrand, P.; Gustavsson, R.

    2006-01-01

    Different driving forces push the electricity production towards decentralization. As a result, the current electricity infrastructure is expected to evolve into a network of networks, in which all system parts communicate with each other and influence each other. Multiagent systems and electronic markets form an appropriate technology needed for control and coordination tasks in the future electricity network. We present the PowerMatcher, a market-based control concept for supply demand matching (SDM) in electricity networks. In a simulation study we show the ability of this approach to raise the simultaneousness of electricity production and consumption within (local) control clusters. This control concept can be applied in different business cases like reduction of imbalance costs in commercial portfolios or virtual power plant operation of distributed generators. Two PowerMatcher-based field test configurations are described, one currently in operation, one currently under construction

  3. Norwegian electricity market liberalisation: questions of cost calculation and price definition by grid operators; Norwegische Elektrizitaetsmarktoeffnung: Kostenrechnungs- und Preisbildungsfragen der Netzgesellschaften

    Energy Technology Data Exchange (ETDEWEB)

    Wild, J.; Vaterlaus, S.

    2002-07-01

    This report for the Swiss Federal Office of Energy (SFOE) presents the results of a study carried out on the Norwegian electricity market 10 years after its liberalisation. The similarity of the Norwegian market to the Swiss electricity market is discussed. Similarly to the proposed situation in Switzerland, the liberalisation in Norway foresaw no privatisation of public utilities and a model for the regulation of grid access was introduced. The report describes and comments on the various phases in which the liberalisation occurred and examines the various instruments used, e.g. to ensure that individual grid operators did not make undue profits from their monopoly. The methods used for the monitoring of grid operators' costs are described and the mechanisms involved in the definition of prices for grid services are examined, including measures taken when profits were too high or too low. The report is concluded with a discussion of the conclusions that can be drawn from the Norwegian model for Swiss market opening efforts.

  4. Operating experience from Swedish nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-06-01

    The total production of electricity from Swedish nuclear power plants was 70.5 TWh during 1998, which is the second highest yearly production ever. Production losses due to low demand totaled 5.1 TWh combined for all twelve units and production losses due to coastdown operation totaled an additional 0.5 TWh. The reason for this low power demand was a very good supply of water to the hydropower system. Hydroelectric power production was 73.6 TWh, an increase by roughly 5 TWh since 1997. Hence, the hydroelectric power production substantially exceeded the 64 TWh expected during a normal year, i.e. a year with average rainfall. Remaining production sources, mainly fossil fuel electricity production combined with district heating, contributed with 10 TWh. The total electricity production was 154.2 TWh, the highest yearly production ever. The total electricity consumption including transmission losses was 143.5 TWh. This is also the highest consumption ever and an increase by one percent compared to 1997. The preliminary net result of the electric power trade shows a net export by 10.7 TWh. The figures above are calculated from the preliminary production results. A comprehensive report on electric power supply and consumption in Sweden is given in the 1998 Annual Report from the Swedish Power Association. Besides Oskarshamn 1, all plants have periodically been operated in load-following mode, mostly because of the abundant supply of hydropower. The energy availability for the three boiling water reactors at Forsmark averaged 93.3 % and for the three pressure water reactors at Ringhals 91.0 %, both figures are the highest ever noted. In the section `Special Reports` three events of importance to safety that occurred during 1998 are reported. The events were all rated as level 1 according to the International Nuclear Event Scale (INES) Figs, tabs.; Also available in Swedish

  5. Operating experience from Swedish nuclear power plants

    International Nuclear Information System (INIS)

    1999-01-01

    The total production of electricity from Swedish nuclear power plants was 70.5 TWh during 1998, which is the second highest yearly production ever. Production losses due to low demand totaled 5.1 TWh combined for all twelve units and production losses due to coastdown operation totaled an additional 0.5 TWh. The reason for this low power demand was a very good supply of water to the hydropower system. Hydroelectric power production was 73.6 TWh, an increase by roughly 5 TWh since 1997. Hence, the hydroelectric power production substantially exceeded the 64 TWh expected during a normal year, i.e. a year with average rainfall. Remaining production sources, mainly fossil fuel electricity production combined with district heating, contributed with 10 TWh. The total electricity production was 154.2 TWh, the highest yearly production ever. The total electricity consumption including transmission losses was 143.5 TWh. This is also the highest consumption ever and an increase by one percent compared to 1997. The preliminary net result of the electric power trade shows a net export by 10.7 TWh. The figures above are calculated from the preliminary production results. A comprehensive report on electric power supply and consumption in Sweden is given in the 1998 Annual Report from the Swedish Power Association. Besides Oskarshamn 1, all plants have periodically been operated in load-following mode, mostly because of the abundant supply of hydropower. The energy availability for the three boiling water reactors at Forsmark averaged 93.3 % and for the three pressure water reactors at Ringhals 91.0 %, both figures are the highest ever noted. In the section 'Special Reports' three events of importance to safety that occurred during 1998 are reported. The events were all rated as level 1 according to the International Nuclear Event Scale (INES)

  6. Hierarchical Load Tracking Control of a Grid-connected Solid Oxide Fuel Cell for Maximum Electrical Efficiency Operation

    DEFF Research Database (Denmark)

    Li, Yonghui; Wu, Qiuwei; Zhu, Haiyu

    2015-01-01

    efficiency operation obtained at different active power output levels, a hierarchical load tracking control scheme for the grid-connected SOFC was proposed to realize the maximum electrical efficiency operation with the stack temperature bounded. The hierarchical control scheme consists of a fast active...... power control and a slower stack temperature control. The active power control was developed by using a decentralized control method. The efficiency of the proposed hierarchical control scheme was demonstrated by case studies using the benchmark SOFC dynamic model......Based on the benchmark solid oxide fuel cell (SOFC) dynamic model for power system studies and the analysis of the SOFC operating conditions, the nonlinear programming (NLP) optimization method was used to determine the maximum electrical efficiency of the grid-connected SOFC subject...

  7. Motor-operated valve (MOV) actuator motor and gearbox testing

    International Nuclear Information System (INIS)

    DeWall, K.; Watkins, J.C.; Bramwell, D.

    1997-07-01

    Researchers at the Idaho National Engineering and Environmental Laboratory tested the performance of electric motors and actuator gearboxes typical of the equipment installed on motor-operated valves used in nuclear power plants. Using a test stand that simulates valve closure loads against flow and pressure, the authors tested five electric motors (four ac and one dc) and three gearboxes at conditions a motor might experience in a power plant, including such off-normal conditions as operation at high temperature and reduced voltage. They also monitored the efficiency of the actuator gearbox. All five motors operated at or above their rated starting torque during tests at normal voltages and temperatures. For all five motors, actual torque losses due to voltage degradation were greater than the losses calculated by methods typically used for predicting motor torque at degraded voltage conditions. For the dc motor the actual torque losses due to elevated operating temperatures were greater than the losses calculated by the typical predictive method. The actual efficiencies of the actuator gearboxes were generally lower than the running efficiencies published by the manufacturer and were generally nearer the published pull-out efficiencies. Operation of the gearbox at elevated temperature did not affect the operating efficiency

  8. New maintenance strategy of Tokyo Electric Power Company and Fukushima Dai-ichi Nuclear Power Plant for effective ageing management and safe long-term operation

    International Nuclear Information System (INIS)

    Inagaki, Takeyuki; Yamashita, Norimichi

    2009-01-01

    Fukushima Dai-ichi Nuclear Power Plant is the oldest among three nuclear power plants owned and operated by Tokyo Electric Power Company, which consists of six boiling water reactor units. The commercial operation of Unit 1 was commenced in 1971 (37 years old) and Unit 6 in 1978 (29 years old). Currently ageing degradations of systems, structures and components are managed through maintenance programs, component replacement/refurbishment programs and long-term maintenance plans. The long-term maintenance plans are established through ageing management component replacement/refurbishment programs reviews performed before the 30th year of operation and they are for safe and reliable operation after 30 years (long-term operation). However the past maintenance actions and past component replacement/refurbishment programs were not always proactive and past operational experience and maintenance practices suggest that effective/proactive ageing management programs be introduced in earlier stage of the plant operation. In this circumstance, Tokyo Electric Power Company and Fukushima Dai-ichi Nuclear Power Plant are setting up a new maintenance strategy that includes 1) improving the normal maintenance programs by using ageing degradation data, 2) effective use of information on internal/external operational experience and maintenance practices related to ageing, and 3) proactive component/equipment refurbishment programs during a refreshment outage for safe and reliable long-term operation. To accomplish the goal of this strategy, strengthening engineering capability of plant staff members is a crucial required for the plant. The objective of this paper is to briefly explain main results ageing management reviews, past and current significant ageing issues and management programs against them, and the new maintenance strategy established by Tokyo Electric Power Company and Fukushima Dai-ichi Nuclear Power Plant. (author)

  9. Evaluation of efficiency in Japan electric power companies

    International Nuclear Information System (INIS)

    Ghaderi, F.; Muyajima, M.

    2001-01-01

    Achieving energy efficiency also must consider supply efficiency, how much energy it takes to generate electricity and transmit it to the end user. system efficiency reflects the loss of energy during the processes of generation, transmission and distribution of electricity. Of the millions of tons of coal that are burned to produce heat in generation of electricity every year, only one third is converted into electricity.The electric power plant immediately uses 5 to 10 percent of that energy for use in the plant. Around another 10 percent of this energy is consumed in the transmission and distribution of electric energy to end users. Overall,more that 70 percent of the energy used to produce and deliver electricity never gets to the end user. The costs of this wasted energy are reflected in the customer's electricity bill. Furthermore, once delivered, users of electricity are subjected to more h idden c osts the demand charge which reflects the rate at which consumers draw energy from the power plant during a particular time of day, are also affected by the time of year. This additional charge c n be dramatic. For example, the cost for using electric air conditioning at the w rong t ime of the day , are also affected by the time of year. This additional charge can be dramatic. For example, the cost for using electric air conditioning at the wrong time of the day could be as much as 25 to 40 percent higher than what a facility normally pays for electricity during off-peak times. Minimizing the costs of operations, therefor, is a must for all electric companies. In the other hand utility rates, such as the cost of electricity, are a necessary element of operating in all enterprises.In some industries the payment over electricity make a large percentage of their total expenses, but that doesn't mean that every effort should not be made to reduce their impact on the bottom line, it should be considered that a very small change in operating procedure can change

  10. All-Si photodetector for telecommunication wavelength based on subwavelength grating structure and critical coupling

    DEFF Research Database (Denmark)

    Taghizadeh, Alireza; Rasoulzadeh Zali, Aref; Chung, Il-Sug

    2017-01-01

    We propose an efficient planar all-Si internal photoemission photodetector operating at the telecommunication wavelength of 1550 nm and numerically investigate its optical and electrical properties. The proposed polarization-sensitive detector is composed of an appropriately engineered subwavelen......We propose an efficient planar all-Si internal photoemission photodetector operating at the telecommunication wavelength of 1550 nm and numerically investigate its optical and electrical properties. The proposed polarization-sensitive detector is composed of an appropriately engineered...

  11. Benchmarking Swiss electricity grids

    International Nuclear Information System (INIS)

    Walti, N.O.; Weber, Ch.

    2001-01-01

    This extensive article describes a pilot benchmarking project initiated by the Swiss Association of Electricity Enterprises that assessed 37 Swiss utilities. The data collected from these utilities on a voluntary basis included data on technical infrastructure, investments and operating costs. These various factors are listed and discussed in detail. The assessment methods and rating mechanisms that provided the benchmarks are discussed and the results of the pilot study are presented that are to form the basis of benchmarking procedures for the grid regulation authorities under the planned Switzerland's electricity market law. Examples of the practical use of the benchmarking methods are given and cost-efficiency questions still open in the area of investment and operating costs are listed. Prefaces by the Swiss Association of Electricity Enterprises and the Swiss Federal Office of Energy complete the article

  12. Island operation capability in the Colombian electrical market: a promising ancillary service of distributed energy resources

    DEFF Research Database (Denmark)

    Marín-Jiménez, Juan D.; Carvajal-Quintero, Sandra; Guerrero, Josep M.

    2018-01-01

    is presented. Subsequently, an existing electrical distribution system with small hydropower plants is considered as a study case in order to identify the technical requirements set out for both, the distribution system and the generation source. Finally, taking into account the current Law and regulations......, a proposal is outlined for the implementation of the island operation capability ancillary service in the Colombian electrical system....

  13. Multi-agent based modeling for electric vehicle integration in a distribution network operation

    DEFF Research Database (Denmark)

    Hu, Junjie; Morais, Hugo; Lind, Morten

    2016-01-01

    The purpose of this paper is to present a multi-agent based modeling technology for simulating and operating a hierarchical energy management of a power distribution system with focus on EVs integration. The proposed multi-agent system consists of four types of agents: i) Distribution system...... operator (DSO) technical agent and ii) DSO market agents that both belong to the top layer of the hierarchy and their roles are to manage the distribution network by avoiding grid congestions and using congestion prices to coordinate the energy scheduled; iii) Electric vehicle virtual power plant agents...

  14. Operational Water Withdrawal and Consumption Factors for Electricity Generation Technology in China—A Literature Review

    Directory of Open Access Journals (Sweden)

    Jinjing Gao

    2018-04-01

    Full Text Available As two indispensable resources for human development, energy and water are closely related. China, as the world’s largest consumer of electricity, is also experiencing very serious water shortages. Understanding the water consumption intensity in various types of electric power production technologies according to China’s national conditions is a prerequisite for understanding the potential impact of electrical power production on water resources. Therefore, following the steps of a meta-analysis, this paper provides a literature review on operational water withdrawal and consumption factors for electricity generation technology in China. We observed that 50% of water consumption for electricity generation was for coal power, whereas there was no research on the water consumption intensity of natural gas power generation, and a shortage of studies on water intake during electrical power production. The average water consumption intensity of hydropower is the largest. The results indicate that compared with other fuel types, hydropower is not a sustainable energy with respect to water conservation, and the study of hydropower applications should be improved in China.

  15. Effects of 60 Hz electric fields on operant and social stress behaviors of nonhuman primates: Projects 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, W.R.; Coelho, A.M. Jr.; Easley, S.P.; Orr, J.L.; Smith, H.D.; Taylor, L.L.; Tuttle, M.L.

    1987-01-01

    The objective of this program is to investigate, using the baboon as a nonhuman primate surrogate for the human, possible hehavioral effects associated with exposure to high intensity 60 Hz electric fields. Results from this program, along with information from experiments conducted elsewhere, will be used by the Department of Energy (DOE) to estimate and evaluate the likelihood of deleterious consequences resulting from exposure of humans to the electric fields associated with power transmission over high voltage lines. This research program consists of four major research projects, all of which have been successfully completed. The third project assessed, in separate experiments conducted at 30 and 60 kV/m, effects of chronic exposure to electric fields on the performance of two operant conditioning tasks, fixed ratio (FR), and differential reinforcement of low rate (DRL). In the same two experiments, the fourth project investigated, using the systematic quantitative observational sampling methods of primatology, the possible stress-inducing effects of chronic exposure to 60 Hz electric fields on the behavior of baboons living in small social groups. This volume contains only appendices for projects 3 and 4. 81 figs., 67 tabs.

  16. Non-operative management of abdominal gunshot injuries: Is it safe in all cases?

    Science.gov (United States)

    İflazoğlu, Nidal; Üreyen, Orhan; Öner, Osman Zekai; Meral, Ulvi Mehmet; Yülüklü, Murat

    2018-01-01

    In line with advances in diagnostic methods and expectation of a decrease in the number of negative laparotomies, selective non-operative management of abdominal gunshot wounds has been increasingly used over the last three decades. We aim to detect the possibility of treatment without surgery and present our experience in selected cases referred from Syria to a hospital at the Turkish-Syrian border. Between February 2012 and June 2014, patients admitted with abdominal gunshot wounds were analyzed. Computed tomography was performed for all patients on admission. Patients who were hemodynamically stable and did not have symptoms of peritonitis at the time of presentation were included in the study. The primary outcome parameters were mortality and morbidity. Successful selective non-operative management (Group 1) and unsuccessful selective non-operative management (Group 2) groups were compared in terms of complications, blood transfusion, injury site, injury severity score (ISS), and hospital stay. Of 158 truncal injury patients, 18 were considered feasible for selective non-operative management. Of these, 14 (78%) patients were treated without surgery. Other Four patients were operated upon progressively increasing abdominal pain and tenderness during follow-up. On diagnostic exploration, all of these cases had intestinal perforations. No mortality was observed in selective non-operative management. There was no statistically significant difference between Group 1 and Group 2, in terms of length of hospital stay (96 and 127 h, respectively). Also, there was no difference between groups in terms of blood transfusion necessity, injury site, complication rate, and injury severity score (p>0.05). Decision making on patient selection for selective non-operative management is critical to ensure favorable outcomes. It is not possible to predict the success of selective non-operative management in advance. Cautious clinical examination and close monitoring of these

  17. Modeling of electrical and mesoscopic circuits at quantum nanoscale from heat momentum operator

    Science.gov (United States)

    El-Nabulsi, Rami Ahmad

    2018-04-01

    We develop a new method to study electrical circuits at quantum nanoscale by introducing a heat momentum operator which reproduces quantum effects similar to those obtained in Suykens's nonlocal-in-time kinetic energy approach for the case of reversible motion. The series expansion of the heat momentum operator is similar to the momentum operator obtained in the framework of minimal length phenomenologies characterized by the deformation of Heisenberg algebra. The quantization of both LC and mesoscopic circuits revealed a number of motivating features like the emergence of a generalized uncertainty relation and a minimal charge similar to those obtained in the framework of minimal length theories. Additional features were obtained and discussed accordingly.

  18. Electrical energy in France in 2009

    International Nuclear Information System (INIS)

    2009-12-01

    The figures presented on this document account for the electricity flows recorded in Metropolitan France, including Corsica. Contents: national consumption; physical exchanges with foreign countries; electrical energy balance in France in 2009; net generation; noteworthy data for the year 2009 (daily maximum values of national consumption, thermal generation, hydro-electric generation, wind generation and balance of physical exchanges); electricity market: cross-borders contractual exchanges, balance responsible entities (Energy amount exchanged between balance responsible entities through the block exchange notifications), balancing mechanism (global amount of energy activated upwards and downwards), daily market coupling; power facilities: generating facilities in France (Nuclear, Fossil fuel thermal, Hydro-electric, Wind and Other renewable energy sources), transmission lines owned by RTE (circuit length in operation), transmission - transformers owned by RTE (installed capacity in operation); main transmission facilities commissioned during the year 2009 (substations connected to the RTE network and new or refurbished circuits)

  19. Wavelet-based information filtering for fault diagnosis of electric drive systems in electric ships.

    Science.gov (United States)

    Silva, Andre A; Gupta, Shalabh; Bazzi, Ali M; Ulatowski, Arthur

    2017-09-22

    Electric machines and drives have enjoyed extensive applications in the field of electric vehicles (e.g., electric ships, boats, cars, and underwater vessels) due to their ease of scalability and wide range of operating conditions. This stems from their ability to generate the desired torque and power levels for propulsion under various external load conditions. However, as with the most electrical systems, the electric drives are prone to component failures that can degrade their performance, reduce the efficiency, and require expensive maintenance. Therefore, for safe and reliable operation of electric vehicles, there is a need for automated early diagnostics of critical failures such as broken rotor bars and electrical phase failures. In this regard, this paper presents a fault diagnosis methodology for electric drives in electric ships. This methodology utilizes the two-dimensional, i.e. scale-shift, wavelet transform of the sensor data to filter optimal information-rich regions which can enhance the diagnosis accuracy as well as reduce the computational complexity of the classifier. The methodology was tested on sensor data generated from an experimentally validated simulation model of electric drives under various cruising speed conditions. The results in comparison with other existing techniques show a high correct classification rate with low false alarm and miss detection rates. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  20. Distributed control of deregulated electrical power networks

    NARCIS (Netherlands)

    Hermans, R.M.

    2012-01-01

    A prerequisite for reliable operation of electrical power networks is that supply and demand are balanced at all time, as efficient ways for storing large amounts of electrical energy are scarce. Balancing is challenging, however, due to the power system's dimensions and complexity, the low

  1. Electric fields, weighting fields, signals and charge diffusion in detectors including resistive materials

    International Nuclear Information System (INIS)

    Riegler, W.

    2016-01-01

    In this report we discuss static and time dependent electric fields in detector geometries with an arbitrary number of parallel layers of a given permittivity and weak conductivity. We derive the Green's functions i.e. the field of a point charge, as well as the weighting fields for readout pads and readout strips in these geometries. The effect of 'bulk' resistivity on electric fields and signals is investigated. The spreading of charge on thin resistive layers is also discussed in detail, and the conditions for allowing the effect to be described by the diffusion equation is discussed. We apply the results to derive fields and induced signals in Resistive Plate Chambers, MICROMEGAS detectors including resistive layers for charge spreading and discharge protection as well as detectors using resistive charge division readout like the MicroCAT detector. We also discuss in detail how resistive layers affect signal shapes and increase crosstalk between readout electrodes.

  2. Electric fields, weighting fields, signals and charge diffusion in detectors including resistive materials

    CERN Document Server

    Riegler, Werner

    2016-11-07

    In this report we discuss static and time dependent electric fields in detector geometries with an arbitrary number of parallel layers of a given permittivity and weak conductivity. We derive the Green's functions i.e. the field of a point charge, as well as the weighting fields for readout pads and readout strips in these geometries. The effect of 'bulk' resistivity on electric fields and signals is investigated. The spreading of charge on thin resistive layers is also discussed in detail, and the conditions for allowing the effect to be described by the diffusion equation is discussed. We apply the results to derive fields and induced signals in Resistive Plate Chambers, Micromega detectors including resistive layers for charge spreading and discharge protection as well as detectors using resistive charge division readout like the MicroCAT detector. We also discuss in detail how resistive layers affect signal shapes and increase crosstalk between readout electrodes.

  3. ANALYSIS OF THE OPERATIONAL CHARACTERISTICS OF DIESEL-ELECTRIC LOCOMOTIVES

    Directory of Open Access Journals (Sweden)

    L. V. Ursulyak

    2014-12-01

    Full Text Available Purpose. To compare the operational characteristics of freight diesel-electric locomotives ER20CF and 2М62м, which are operated with Lithuanian Railways. Important problems on traction calculations are considered in this article. In this article the critical tasks of traction calculations are solved. It is the main computational tool in the rational functioning, planning and development of railways: determination of the estimated weight of the rolling stock, the diagrams construction of specific resultant forces of a train, the permitted speed definition of the train on the slopes, curves of train traffic construction on the section. Methodology. Using the rules and methods of traction calculations the analysis of the basic operational characteristics of the modernized freight diesel-electric locomotive 2М62m and freight passenger dual locomotive 2ER20CF was held. The maximum weight of the train set, the track structure on a high-speed ascent through the use of kinetic energy (with traction and without traction, technical speed, acceleration force and the value of the smallest radius curve are selected as controlled parameters. During the calculations it was considered that the trains were formed of a fully loaded four-axle gondola cars, model 112-119 (feature-606 with axle load of 23.5 t; the motion was carried out on the continuous welded rail track; the front of the train set is a dual locomotive 2ER20CF or two locomotive 2М62м. Longitudinal profile of the road on the route Vilnus–KlF was analyzed for the choice of theoretical rise. Inspection concerning the possibility of overcoming the high-speed rise was performed with an analytical method, based on the use of the kinetic energy accumulated by the overcoming of «light» elements of the profile. Findings. In the calculations, the maximum weight of the train set taking into account theoretical rise was analyzed. The inspection of the theoretical weight of the train set on a reliable

  4. The electricity business: a chess player vision

    International Nuclear Information System (INIS)

    Mataix, J.

    1999-01-01

    It looks like that all over the world things are changing. Many countries, Spain among them, where electricity regulations were usual, are changing its regulatory mainframe. Since January 1, 1998 electricity production is a de-regulated activity in Spain. There has to be open market competition. Prices which are very important for the time coming, have to cover the production cost plus some profits in order to maintain the company profitability. This cultural change applies to all our production facilities, including nuclear power plants. Taking into account this new situation and the nuclear competitiveness, it is important for all of us to understand this issue. As it is well known, nuclear energy is capital intensive, that means it has to compete as base load units due to their low operating costs and their large capital ones. For that reason it is important to reduce as much as possible the operating and maintenance cost as well as the fuel one, which will allow nuclear plants to compete in marginal costs with others units. Nuclear energy, in Spain, is not going to fix the pool price but it has to recover some depreciation through it, the remaining being recovered by the recognition of an important part of the stranded cost. (author)

  5. Projected cost comparison of nuclear electricity

    International Nuclear Information System (INIS)

    Juhn, P.E.; Hu, C.W.

    2000-01-01

    Comparison of electricity generation costs has been done in the late years through a large co-operation between several organisations. The studies are aiming to provide reliable comparison of electricity generating costs of nuclear and conventional base load power plants. This paper includes the result of the joint IAEA/OECD study published in 1997. (author)

  6. Powertrain system for a hybrid electric vehicle

    Science.gov (United States)

    Reed, Jr., Richard G.; Boberg, Evan S.; Lawrie, Robert E.; Castaing, Francois J.

    1999-08-31

    A hybrid electric powertrain system is provided including an electric motor/generator drivingly engaged with the drive shaft of a transmission. The electric is utilized for synchronizing the rotation of the drive shaft with the driven shaft during gear shift operations. In addition, a mild hybrid concept is provided which utilizes a smaller electric motor than typical hybrid powertrain systems. Because the electric motor is drivingly engaged with the drive shaft of the transmission, the electric motor/generator is driven at high speed even when the vehicle speed is low so that the electric motor/generator provides more efficient regeneration.

  7. Powertrain system for a hybrid electric vehicle

    Science.gov (United States)

    Reed, R.G. Jr.; Boberg, E.S.; Lawrie, R.E.; Castaing, F.J.

    1999-08-31

    A hybrid electric powertrain system is provided including an electric motor/generator drivingly engaged with the drive shaft of a transmission. The electric is utilized for synchronizing the rotation of the drive shaft with the driven shaft during gear shift operations. In addition, a mild hybrid concept is provided which utilizes a smaller electric motor than typical hybrid powertrain systems. Because the electric motor is drivingly engaged with the drive shaft of the transmission, the electric motor/generator is driven at high speed even when the vehicle speed is low so that the electric motor/generator provides more efficient regeneration. 34 figs.

  8. Impacts of Severe Space Weather on the Electric Grid

    Science.gov (United States)

    2011-11-01

    human infrastructure are examined, particularly in how they generate geomagnetically induced currents (GICs) in electric grids. The solar origins of...capacitors and AC and HVDC transmission lines all have tripped in prior storms due to relay mis-operations’ (J. Kappenman, Jason Presentation 2011). Over...called quasi-satellite orbits because many large bodies , including the Earth have small "companion" objects in quasi-spacecraft orbits around them

  9. Neural network based photovoltaic electrical forecasting in south Algeria

    International Nuclear Information System (INIS)

    Hamid Oudjana, S.; Hellal, A.; Hadj Mahammed, I

    2014-01-01

    Photovoltaic electrical forecasting is significance for the optimal operation and power predication of grid-connected photovoltaic (PV) plants, and it is important task in renewable energy electrical system planning and operating. This paper explores the application of neural networks (NN) to study the design of photovoltaic electrical forecasting systems for one week ahead using weather databases include the global irradiance, and temperature of Ghardaia city (south of Algeria) for one year of 2013 using a data acquisition system. Simulations were run and the results are discussed showing that neural networks Technique is capable to decrease the photovoltaic electrical forecasting error. (author)

  10. 46 CFR 76.27-15 - Operation and installation.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Operation and installation. 76.27-15 Section 76.27-15... EQUIPMENT Electric Fire Detecting System, Details § 76.27-15 Operation and installation. (a) The system... system. (e) All wiring and electrical circuits and equipment shall meet the applicable requirements of...

  11. Distributed Energy Systems Integration and Demand Optimization for Autonomous Operations and Electric Grid Transactions

    Energy Technology Data Exchange (ETDEWEB)

    Ghatikar, Girish [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Greenlots, San Francisco, CA (United States); Mashayekh, Salman [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stadler, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Center for Energy and Innovation Technologies (Austria); Yin, Rongxin [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Liu, Zhenhua [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-11-29

    Distributed power systems in the U.S. and globally are evolving to provide reliable and clean energy to consumers. In California, existing regulations require significant increases in renewable generation, as well as identification of customer-side distributed energy resources (DER) controls, communication technologies, and standards for interconnection with the electric grid systems. As DER deployment expands, customer-side DER control and optimization will be critical for system flexibility and demand response (DR) participation, which improves the economic viability of DER systems. Current DER systems integration and communication challenges include leveraging the existing DER and DR technology and systems infrastructure, and enabling optimized cost, energy and carbon choices for customers to deploy interoperable grid transactions and renewable energy systems at scale. Our paper presents a cost-effective solution to these challenges by exploring communication technologies and information models for DER system integration and interoperability. This system uses open standards and optimization models for resource planning based on dynamic-pricing notifications and autonomous operations within various domains of the smart grid energy system. It identifies architectures and customer engagement strategies in dynamic DR pricing transactions to generate feedback information models for load flexibility, load profiles, and participation schedules. The models are tested at a real site in California—Fort Hunter Liggett (FHL). Furthermore, our results for FHL show that the model fits within the existing and new DR business models and networked systems for transactive energy concepts. Integrated energy systems, communication networks, and modeling tools that coordinate supply-side networks and DER will enable electric grid system operators to use DER for grid transactions in an integrated system.

  12. Prices on electricity and transmission of electricity

    International Nuclear Information System (INIS)

    2003-01-01

    This publication contains data on prices of electric energy and transmission of electricity valid from 1 January 2003. The purpose is to illustrate the price changes on the electricity market in terms of prices for different customer categories. All companies holding network concessions for areas and all companies trading in electricity are included in this report, which is produced on an annual basis.The prices for transmission services 1 January 2003 were on the whole unchanged compared to the preceding year. For households the mean annual cost was SEK 882 for flats, SEK 4 335 for one- or two-family houses with electric heating and SEK 1 925 for those without electric heating. Electricity prices rose considerably on 1 January 2003 compared to the year before. The mean price per kWh for households with standard agreements was SEK 0.519 for deliveries to flats, SEK 0.447 for one- or two-family houses with electric heating and SEK 0.471 without electric heating. As a result, the mean annual cost increased by SEK 326 for flats, SEK 3 012 for one- or two-family houses with electric heating, and by SEK 774 for those houses without electric heating. The high costs of electricity may be explained in part by the development on the Nordic Power Exchange (Nord Pool), where the spot price increased by about 290 per cent during 2002 (1 USD is about 8 SEK)

  13. A novel approach to electricity market education

    International Nuclear Information System (INIS)

    Karjalainen, R.; Viljainen, S.; Partanen, J.

    2007-01-01

    The special characteristics of the competitive Nordic electricity markets were discussed with particular references to the challenges of operating an open power market. Electricity prices in Norway are highly volatile and difficult to estimate because the demand for electricity depends highly on temperature, while the supply of electricity is influenced by water reservoir levels and the price of carbon dioxide allowances. An innovative approach to power engineering education was proposed in an effort to provide power engineering students at Lappeenranta University of Technology (LUT) with skills that are needed for open electricity markets. In addition to the basic power engineering skills, these include an understand of risk management, financing, sales and marketing. The approach was based on developing theoretical and practical teaching methods that are applied in power engineering education at LUT. The practical learning methods played a key role in the development of a Power Exchange Game which was based on the operation of the Nordic power exchange Nord Pool. During the game, student teams used their knowledge and acted as portfolio managers of electric utilities where they analyzed and made decisions regarding the operation in the Nordic electricity market. Upon completion of the game, students were expected analyze their own performance in a final report. Most of the students considered the course an effective and interesting way to study the operation of electricity markets. 9 refs., 1 tab., 9 figs

  14. The economics of electricity markets

    CERN Document Server

    Biggar, Darryl R

    2014-01-01

    With the transition to liberalized electricity markets in many countries, the shift to more environmentally sustainable forms of power generation and increasing penetration of electric vehicles and smart appliances, a fundamental understanding of the economic principles underpinning the electricity industry is vital. Using clarity and precision, the authors successfully explain economic theory of all liberalized electricity market types from a cross-disciplinary engineering and policy perspective. No prior engineering knowledge or economics expertise is assumed in introducing key ideas such as nodal pricing, optimal dispatch and efficient pricing or in extending those models to areas including investment, risk management and the handling of contingencies. Key features: Comprehensively covers the principles of all liberalized electricity market types, including the US, Europe, New Zealand and Australia. Provides up to date coverage of research and policy iss es, including design of financial transmission rig...

  15. Proceedings of the international symposium on uranium and electricity

    International Nuclear Information System (INIS)

    Talbot, K.H.; Lakshmanan, V.I.

    1988-01-01

    The first Canadian Nuclear Society 'Uranium and Electricity' Conference provided a forum for discussion on developments in all phases of the nuclear/electricity fuel cycle. It included both technical and management aspects in areas of mutual interest to those involved in mining, refining, fuel manufacture, reactor operation and irradiated fuel. The 60 papers offered in this volume present detailed discussions on uranium exploration and mining; waste management; uranium metallurgy, refining and byproducts; irradiated fuel management; effluent management, uranium chemistry, refining and the environment; environmental protection from low level waste; fuel design, manufacture and performance; regulation and control of radiological hazards; Canadian power reactor fuel and safety trends; and future developments

  16. Cost analysis of operating an all-digital radiology department

    International Nuclear Information System (INIS)

    Arenson, R.L.; Soshadri, S.B.; DeSimone, D.; Hiss, S.S.

    1988-01-01

    Using the current film system as a baseline, this study analyzes the cost of digital acquisition, transmission, archiving, and display of all images generated in our department. Two approaches are considered: (1) conventional x-ray films are digitized with a laser scanning film digitizer; (2) images are captured with a direct digital receptor and no film is created. In both approaches, images from digital modalities are acquired directly from the scanners. The cost of equipment and its maintenance, film, supplies, storage space, operations, personnel, and so forth are analyzed for all approaches. The annual cost of operating the film system is $2.5 million. The estimated annual cost is $2.3 million for the first digital approach, $1.8 million for the second. This analysis demonstrates that these digital approaches can be cost-effective, viable alternatives to film-bases systems

  17. Integrating wind power using intelligent electric water heating

    International Nuclear Information System (INIS)

    Fitzgerald, Niall; Foley, Aoife M.; McKeogh, Eamon

    2012-01-01

    Dwindling fossil fuel resources and pressures to reduce greenhouse gas emissions will result in a more diverse range of generation portfolios for future electricity systems. Irrespective of the portfolio mix the overarching requirement for all electricity suppliers and system operators is to instantaneously meet demand, to operate to standards and reduce greenhouse gas emissions. Therefore all electricity market participants will ultimately need to use a variety of tools to balance the power system. Thus the role of demand side management with energy storage will be paramount to integrate future diverse generation portfolios. Electric water heating has been studied previously, particularly at the domestic level to provide load control, peak shave and to benefit end-users financially with lower bills, particularly in vertically integrated monopolies. In this paper a number of continuous direct load control demand response based electric water heating algorithms are modelled to test the effectiveness of wholesale electricity market signals to study the system benefits. The results are compared and contrasted to determine which control algorithm showed the best potential for energy savings, system marginal price savings and wind integration.

  18. A Study of Digging Productivity of an Electric Rope Shovel for Different Operators

    Directory of Open Access Journals (Sweden)

    Mohammad Babaei Khorzoughi

    2016-05-01

    Full Text Available A performance monitoring study of an electric rope shovel operating in an open pit coal mine was conducted. As the mining industry moves toward higher productivity, profitability and predictability, the need for more reliable, productive and efficient mining shovels increases. Consequently, it is critical to study the productivity of these machines and to understand the effect of different operational parameters on that. In this paper a clustering analysis is performed to classify shovel digging effort and behaviour based on digging energy, dig time and payload per pass. Then the influence of the operator on the digging efficiency and productivity of the machine is analyzed with a focus on operator technique during digging. A statistical analysis is conducted on different cycle time components (dig time, swing time, return time for different operators. In addition to time components, swing and return angles as well as loading rate and mucking rate are observed and analyzed. The results of this study help to understand the effect of different operators on the digging productivity of the shovel and then to set the best operator practice.

  19. 14 CFR 399.111 - All operations of federally authorized carriers to be regulated by the Board.

    Science.gov (United States)

    2010-01-01

    ... SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) POLICY STATEMENTS STATEMENTS OF GENERAL POLICY Policies Relating to Federal Preemption of State Economic Regulations § 399.111 All operations of... carriers are subject to the requirements of Title IV of the Act, including certification and tariff-filing...

  20. Electric Energy Consumption of Multi Purpose Reactor GA. Siwabessy During Reactor Operation

    International Nuclear Information System (INIS)

    Koes Indrakoesoema

    2012-01-01

    Electrical power supply of Reactor Center Multi Purpose obtained from PT PLN to 3030 kVA power contracts. Distribution to existing loads in PRSG divided into 3 (three) lines, each of which is supplied through a transformer BHT01, BHT02 and BHT03, each transformer have capacity of 1600 kVA. During reactor operation, only 2 lines that serve loads, each line serve 2 primary pump motor and 2 secondary pump motor. Electrical power for 24 hours for measurement BHT01, the average is 288 kW, for BHT02 is 641 kW and BHT03 is 466 kW. The energy absorbed by each transformer for 24 hours of measurement, for BHT01 is 6.44 MWh, BHT02 absorb 14.8 MWh and BHT03 absorb 10.9 MWh. (author)

  1. Optimal stochastic short-term thermal and electrical operation of fuel cell/photovoltaic/battery/grid hybrid energy system in the presence of demand response program

    International Nuclear Information System (INIS)

    Majidi, Majid; Nojavan, Sayyad; Zare, Kazem

    2017-01-01

    Highlights: • On-grid photovoltaic/battery/fuel cell system is considered as hybrid system. • Thermal and electrical operation of hybrid energy system is studied. • Hybrid energy system is used to reduce dependency on upstream grid for load serving. • Demand response program is proposed to manage the electrical load. • Demand response program is proposed to reduce hybrid energy system’s operation cost. - Abstract: In this paper, cost-efficient operation problem of photovoltaic/battery/fuel cell hybrid energy system has been evaluated in the presence of demand response program. Each load curve has off-peak, mid and peak time periods in which the energy prices are different. Demand response program transfers some amount of load from peak periods to other periods to flatten the load curve and minimize total cost. So, the main goal is to meet the energy demand and propose a cost-efficient approach to minimize system’s total cost including system’s electrical cost and thermal cost and the revenue from exporting power to the upstream grid. A battery has been utilized as an electrical energy storage system and a heat storage tank is used as a thermal energy storage system to save energy in off-peak and mid-peak hours and then supply load in peak hours which leads to reduction of cost. The proposed cost-efficient operation problem of photovoltaic/battery/fuel cell hybrid energy system is modeled by a mixed-integer linear program and solved by General algebraic modeling system optimization software under CPLEX solver. Two case studies are investigated to show the effects of demand response program on reduction of total cost.

  2. Hierarchical Load Tracking Control of a Grid-Connected Solid Oxide Fuel Cell for Maximum Electrical Efficiency Operation

    Directory of Open Access Journals (Sweden)

    Yonghui Li

    2015-03-01

    Full Text Available Based on the benchmark solid oxide fuel cell (SOFC dynamic model for power system studies and the analysis of the SOFC operating conditions, the nonlinear programming (NLP optimization method was used to determine the maximum electrical efficiency of the grid-connected SOFC subject to the constraints of fuel utilization factor, stack temperature and output active power. The optimal operating conditions of the grid-connected SOFC were obtained by solving the NLP problem considering the power consumed by the air compressor. With the optimal operating conditions of the SOFC for the maximum efficiency operation obtained at different active power output levels, a hierarchical load tracking control scheme for the grid-connected SOFC was proposed to realize the maximum electrical efficiency operation with the stack temperature bounded. The hierarchical control scheme consists of a fast active power control and a slower stack temperature control. The active power control was developed by using a decentralized control method. The efficiency of the proposed hierarchical control scheme was demonstrated by case studies using the benchmark SOFC dynamic model.

  3. 78 FR 70163 - Communication of Operational Information between Natural Gas Pipelines and Electric Transmission...

    Science.gov (United States)

    2013-11-22

    ... Street NE., Washington, DC 20426, (202) 502-8931, [email protected] . Anna Fernandez (Legal Information), Office of the General Counsel, 888 First Street NE., Washington, DC 20426, (202) 502-6682, anna.... Questions Posed by the Commission 100. A. Generator to Electric Transmission Operator 100. Communications 1...

  4. Maritime Electric Co. Ltd. annual report, 1991

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-01

    Maritime Electric Company is a Canadian investor-owned electric utility based in Prince Edward Island. Established in 1918, the Company owns and operates a fully integrated system providing for the generation, transmission, and distribution of electricity throughout the Island. Maritime Electric operates generating plants in Charlottetown and Borden, and has an equity interest in NB Power's unit in Dalhousie, New Brunswick. Its 4,400 km distribution system and 560 km transmission system are linked to the mainland power grid by two submarine cables between the Island and the province of New Brunswick. This report describes the Company's operations, power production and sales for the year, with relevant statistical information. Financial statements are also included. In 1991 increases in operating revenue were lower than forecast due to the recession. Tight control of expenses, together with higher rates allowed a satisfactory rate of return. Earnings per share were $1.79 compared to $1.61 in 1990. Demand side management initiatives were enhanced, and a customer survey indicated satisfaction with service. Plant life extension programs continued at the Charlottetown generating station.

  5. Maritime Electric Co. Ltd. annual report, 1991

    International Nuclear Information System (INIS)

    1991-01-01

    Maritime Electric Company is a Canadian investor-owned electric utility based in Prince Edward Island. Established in 1918, the Company owns and operates a fully integrated system providing for the generation, transmission, and distribution of electricity throughout the Island. Maritime Electric operates generating plants in Charlottetown and Borden, and has an equity interest in NB Power's unit in Dalhousie, New Brunswick. Its 4,400 km distribution system and 560 km transmission system are linked to the mainland power grid by two submarine cables between the Island and the province of New Brunswick. This report describes the Company's operations, power production and sales for the year, with relevant statistical information. Financial statements are also included. In 1991 increases in operating revenue were lower than forecast due to the recession. Tight control of expenses, together with higher rates allowed a satisfactory rate of return. Earnings per share were $1.79 compared to $1.61 in 1990. Demand side management initiatives were enhanced, and a customer survey indicated satisfaction with service. Plant life extension programs continued at the Charlottetown generating station

  6. Effects of two-photon absorption on all optical logic operation based on quantum-dot semiconductor optical amplifiers

    Science.gov (United States)

    Zhang, Xiang; Dutta, Niloy K.

    2018-01-01

    We investigate all-optical logic operation in quantum-dot semiconductor optical amplifier (QD-SOA) based Mach-Zehnder interferometer considering the effects of two-photon absorption (TPA). TPA occurs during the propagation of sub-picosecond pulses in QD-SOA, which leads to a change in carrier recovery dynamics in quantum-dots. We utilize a rate equation model to take into account carrier refill through TPA and nonlinear dynamics including carrier heating and spectral hole burning in the QD-SOA. The simulation results show the TPA-induced pumping in the QD-SOA can reduce the pattern effect and increase the output quality of the all-optical logic operation. With TPA, this scheme is suitable for high-speed Boolean logic operation at 320 Gb/s.

  7. Operation, Investment and Hedging in Electricity Markets

    DEFF Research Database (Denmark)

    Ernstsen, Rune Ramsdal

    inflexible generation more than flexible generation due to the exposure to potential low prices. In Chapter 4 we study the valuation of three representative generation types, an inflexible wind turbine, a flexible gas fired power plant and a hydroelectric plant that allows for storage. We account...... for the special characteristics of each technology and include uncertainty in both price and volume through diffusion or jump diffusion models. We find explicit expressions for the expected instantaneous value of wind generation as a function of electricity price and wind speed. We include startup and shutdown...... costs for the gas fired power plant determine the startup and shutdown triggers as well as the value of the plant by maximizing the value of shutting down. This is done analytically in the diffusion models and numerically in the jump diffusion model. For the hydroelectric power plant we relax storage...

  8. Energy efficiency improvement of medical electric tools and devices

    Directory of Open Access Journals (Sweden)

    Meshkov Aleksandr S.

    2014-01-01

    Full Text Available With the ever-increasing volume of applications of various kinds of electric drives in all spheres of human activity, the issues in improving the efficiency of the electromechanical converters of electric energy, one of the most important components of the electric drive (ED, are becoming increasingly important. Such issues include reducing their weight and size, improving the functional characteristics of these devices to increase their operational life and reducing the cost of manufacture. Taking full advantage of these opportunities relates to the AC and DC single-phase commutator motor (SCM, which is widely used in regulated and high-speed motor drives in medical electric hand tools. The SCM is used in machinery where the load torque has a hyperbolic dependence on the rotational speed and the need to work with a large motor overload due to the “soft” mechanical characteristics of such motors.

  9. Electric vehicles

    Science.gov (United States)

    1990-03-01

    Quiet, clean, and efficient, electric vehicles (EVs) may someday become a practical mode of transportation for the general public. Electric vehicles can provide many advantages for the nation's environment and energy supply because they run on electricity, which can be produced from many sources of energy such as coal, natural gas, uranium, and hydropower. These vehicles offer fuel versatility to the transportation sector, which depends almost solely on oil for its energy needs. Electric vehicles are any mode of transportation operated by a motor that receives electricity from a battery or fuel cell. EVs come in all shapes and sizes and may be used for different tasks. Some EVs are small and simple, such as golf carts and electric wheel chairs. Others are larger and more complex, such as automobile and vans. Some EVs, such as fork lifts, are used in industries. In this fact sheet, we will discuss mostly automobiles and vans. There are also variations on electric vehicles, such as hybrid vehicles and solar-powered vehicles. Hybrid vehicles use electricity as their primary source of energy, however, they also use a backup source of energy, such as gasoline, methanol or ethanol. Solar-powered vehicles are electric vehicles that use photovoltaic cells (cells that convert solar energy to electricity) rather than utility-supplied electricity to recharge the batteries. These concepts are discussed.

  10. A Common Definition of the System Operators' Core Activities[Electric Power Transmission System Operator

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-02-15

    transmission capacities and coordinating the maintenance operation across the borders. Exercise consistent and coordinated transmission capacity calculation procedures to secure the system operation for the day-ahead when establishing the capacity available to the markets. Implement common procedures for the congestion management in the case of congestions according to the EC Regulation 1228/2003 and guidelines under it. Secure the power system operation during the operational hour according to the binding operational agreement and utilising the available resources within the power system effectively with the help of measurements and control systems. Manage disturbances by proper system protection planning and activate remedial actions without delay using the automatic and manual disturbance reserves and automatic load shedding if required; in the case of the system blackout ensure the black start capability and rapid system restoration. Maintain balance between supply and demand within the operational hour by the automatic frequency control and the regulation market including demand response. Manage the shortage situation together with authorities by up-to-date action plans and agreements including enforced disconnections. The core activity for the TSO as a balance settlement responsible (not necessarily within the same entity) is: Execute the national balance settlement by setting imbalance pricing and settlement principles for imbalances and by setting routines for measuring and reporting. The core activities of the Nordic TSOs are quite similar. However, the organisation of the core activities under the legislative framework, and the way they are conducted is differently managed within the Nordic countries, just as the regulator's role is not the same in all the Nordic countries with regard to the supervision of the TSO.

  11. Evolution of Italian national electric power system: Relationship between ENEL and local operators

    International Nuclear Information System (INIS)

    Rossi, G.P.

    1993-01-01

    With the aim of facilitating the option to privatize the Italian national electricity system known as ENEL (Italian National Electricity Board), new laws have been passed which have modified the legal framework pertaining to the management of ENEL's activities and have given ENEL a new status of state concessionaire. The modifications to the existing laws, however, were made in such a way as not to jeopardize the present integral nature of ENEL's activities relative to power generation and distribution. This paper discusses the impact of the new laws on the management of municipal and industrial power plants run by public administrations and private industrial firms licensed to operate under existing and future agreements made with ENEL

  12. Planning low-carbon electricity systems under uncertainty considering operational flexibility and smart grid technologies.

    Science.gov (United States)

    Moreno, Rodrigo; Street, Alexandre; Arroyo, José M; Mancarella, Pierluigi

    2017-08-13

    Electricity grid operators and planners need to deal with both the rapidly increasing integration of renewables and an unprecedented level of uncertainty that originates from unknown generation outputs, changing commercial and regulatory frameworks aimed to foster low-carbon technologies, the evolving availability of market information on feasibility and costs of various technologies, etc. In this context, there is a significant risk of locking-in to inefficient investment planning solutions determined by current deterministic engineering practices that neither capture uncertainty nor represent the actual operation of the planned infrastructure under high penetration of renewables. We therefore present an alternative optimization framework to plan electricity grids that deals with uncertain scenarios and represents increased operational details. The presented framework is able to model the effects of an array of flexible, smart grid technologies that can efficiently displace the need for conventional solutions. We then argue, and demonstrate via the proposed framework and an illustrative example, that proper modelling of uncertainty and operational constraints in planning is key to valuing operationally flexible solutions leading to optimal investment in a smart grid context. Finally, we review the most used practices in power system planning under uncertainty, highlight the challenges of incorporating operational aspects and advocate the need for new and computationally effective optimization tools to properly value the benefits of flexible, smart grid solutions in planning. Such tools are essential to accelerate the development of a low-carbon energy system and investment in the most appropriate portfolio of renewable energy sources and complementary enabling smart technologies.This article is part of the themed issue 'Energy management: flexibility, risk and optimization'. © 2017 The Author(s).

  13. Electrical energy in France in 2008

    International Nuclear Information System (INIS)

    2008-12-01

    The figures presented on this document account for the electricity flows recorded in Metropolitan France, including Corsica. Contents: national consumption; physical exchanges with foreign countries; electrical energy balance in France in 2008; net generation; noteworthy data for the year 2008 (daily maximum values of National consumption, Hydroelectric generation and non-Hydroelectric generation, Balance of physical exchanges); electricity market: cross-border contractual exchanges, balance responsible entities (Energy amount exchanged between balance responsible entities through the block exchange notifications), balancing mechanism (Global amount of energy activated upwards and downwards); power facilities: generating facilities in France (Nuclear, Fossil fuel thermal, Hydro-electric, Wind and Other renewable energy sources), transmission lines (circuit length in operation), transmission - transformers (installed capacity in operation); main transmission facilities commissioned during the year 2008 (substations connected to the RTE network and new or refurbished circuits)

  14. Electric distribution systems and embedded generation capacity

    International Nuclear Information System (INIS)

    Calderaro, V.; Galdi, V.; Piccolo, A.; Siano, P.

    2006-01-01

    The main policy issues of European States are sustainable energy supply promotion and liberalization of energy markets, which introduced market competition in electricity production and created support mechanisms to encourage renewable electricity production and consumption. As a result of liberalization, any generator, including small-scale and renewable energy based units, can sell electricity on the free market. In order to meet future sustainability targets, connection of a higher number of Distributed Generation (DG) units to the electrical power system is expected, requiring changes in the design and operation of distribution electricity systems, as well as changes in electricity network regulation. In order to assist distribution system operators in planning and managing DG connections and in maximizing DG penetration and renewable sources exploitation, this paper proposed a reconfiguration methodology based on a Genetic Algorithm (GA), that was tested on a 70-bus system with DG units. The simulation results confirmed that the methodology represents a suitable tool for distribution system operators when dealing with DG capacity expansion and power loss issues, providing information regarding the potential penetration network-wide and allowing maximum exploitation of renewable generation. 35 refs., 4 tabs., 6 figs

  15. Total life cycle cost model for electric power stations

    International Nuclear Information System (INIS)

    Cardullo, M.W.

    1995-01-01

    The Total Life Cycle Cost (TLCC) model for electric power stations was developed to provide a technology screening model. The TLCC analysis involves normalizing cost estimates with respect to performance standards and financial assumptions and preparing a profile of all costs over the service life of the power station. These costs when levelized present a value in terms of a utility electricity rate. Comparison of cost and the pricing of the electricity for a utility shows if a valid project exists. Cost components include both internal and external costs. Internal costs are direct costs associated with the purchase, and operation of the power station and include initial capital costs, operating and maintenance costs. External costs result from societal and/or environmental impacts that are external to the marketplace and can include air quality impacts due to emissions, infrastructure costs, and other impacts. The cost stream is summed (current dollars) or discounted (constant dollars) to some base year to yield a overall TLCC of each power station technology on a common basis. While minimizing life cycle cost is an important consideration, it may not always be a preferred method for some utilities who may prefer minimizing capital costs. Such consideration does not always result in technology penetration in a marketplace such as the utility sector. Under various regulatory climates, the utility is likely to heavily weigh initial capital costs while giving limited consideration to other costs such as societal costs. Policy makers considering external costs, such as those resulting from environmental impacts, may reach significantly different conclusions about which technologies are most advantageous to society. The TLCC analysis model for power stations was developed to facilitate consideration of all perspectives

  16. Data and code for the exploratory data analysis of the electrical energy demand in the time domain in Greece.

    Science.gov (United States)

    Tyralis, Hristos; Karakatsanis, Georgios; Tzouka, Katerina; Mamassis, Nikos

    2017-08-01

    We present data and code for visualizing the electrical energy data and weather-, climate-related and socioeconomic variables in the time domain in Greece. The electrical energy data include hourly demand, weekly-ahead forecasted values of the demand provided by the Greek Independent Power Transmission Operator and pricing values in Greece. We also present the daily temperature in Athens and the Gross Domestic Product of Greece. The code combines the data to a single report, which includes all visualizations with combinations of all variables in multiple time scales. The data and code were used in Tyralis et al. (2017) [1].

  17. Intelligent electrical outlet for collective load control

    Science.gov (United States)

    Lentine, Anthony L.; Ford, Justin R.; Spires, Shannon V.; Goldsmith, Steven Y.

    2015-10-27

    Various technologies described herein pertain to an electrical outlet that autonomously manages loads in a microgrid. The electrical outlet can provide autonomous load control in response to variations in electrical power generation supply in the microgrid. The electrical outlet includes a receptacle, a sensor operably coupled to the receptacle, and an actuator configured to selectively actuate the receptacle. The sensor measures electrical parameters at the receptacle. Further, a processor autonomously controls the actuator based at least in part on the electrical parameters measured at the receptacle, electrical parameters from one or more disparate electrical outlets in the microgrid, and a supply of generated electric power in the microgrid at a given time.

  18. Hybrid-electric propulsion for automotive and aviation applications

    OpenAIRE

    Friedrich, C; Robertson, Paul Andrew

    2014-01-01

    In parallel with the automotive industry, hybrid-electric propulsion is becoming a viable alternative propulsion technology for the aviation sector and reveals potential advantages including fuel savings, lower pollution, and reduced noise emission. Hybrid-electric propulsion systems can take advantage of the synergy between two technologies by utilizing both internal combustion engines and electric motors together, each operating at their respective optimum conditions...

  19. An analysis of the South East Europe electricity market

    International Nuclear Information System (INIS)

    Majstrovic, G.; Tot, M.; Medic, I.

    2006-01-01

    Until October 2004, the South East European (SEE) power system had never been connected in unified parallel operation. For the first time in history, all of continental Europe became a single synchronous electricity area with 450 million people in 22 countries. At the Union for the Co-ordination of Transmission of Electricity (UCTE), regional countries in the SEE agreed to create a stable common regulatory and market framework capable of attracting investment in gas networks, power generation and transmission networks, so that all countries would have access to the stable and continuous gas and electricity supply that is essential for economic development and social stability. This paper provided an overview of the electricity market in the SEE and discussed the advantages and disadvantages of the regional market. A brief description of each relevant country in the context of power issues was presented. It also provided some results of a long term generation and transmission development planning Geographic Information system study for the SEE region and analysed the influence on regional security of supply. In this regard, investment opportunities were identified. It was concluded that the main disadvantages in regional energy market establishing include differences in levels of economy; production and consumption structure; energy prices; purchasing power parity; energy sector organization; transmission bottlenecks; power plant aging, low efficiency and problems in environmental protection. The main advantages should cover lower total development expense and system operation as well as higher supply security. 4 tabs., 3 figs., 8 refs

  20. Bulk electric system reliability evaluation incorporating wind power and demand side management

    Science.gov (United States)

    Huang, Dange

    Electric power systems are experiencing dramatic changes with respect to structure, operation and regulation and are facing increasing pressure due to environmental and societal constraints. Bulk electric system reliability is an important consideration in power system planning, design and operation particularly in the new competitive environment. A wide range of methods have been developed to perform bulk electric system reliability evaluation. Theoretically, sequential Monte Carlo simulation can include all aspects and contingencies in a power system and can be used to produce an informative set of reliability indices. It has become a practical and viable tool for large system reliability assessment technique due to the development of computing power and is used in the studies described in this thesis. The well-being approach used in this research provides the opportunity to integrate an accepted deterministic criterion into a probabilistic framework. This research work includes the investigation of important factors that impact bulk electric system adequacy evaluation and security constrained adequacy assessment using the well-being analysis framework. Load forecast uncertainty is an important consideration in an electrical power system. This research includes load forecast uncertainty considerations in bulk electric system reliability assessment and the effects on system, load point and well-being indices and reliability index probability distributions are examined. There has been increasing worldwide interest in the utilization of wind power as a renewable energy source over the last two decades due to enhanced public awareness of the environment. Increasing penetration of wind power has significant impacts on power system reliability, and security analyses become more uncertain due to the unpredictable nature of wind power. The effects of wind power additions in generating and bulk electric system reliability assessment considering site wind speed

  1. All-Electrical Spin Field Effect Transistor in van der Waals Heterostructures at Room Temperature

    Science.gov (United States)

    Dankert, André; Dash, Saroj

    Spintronics aims to exploit the spin degree of freedom in solid state devices for data storage and information processing. Its fundamental concepts (creation, manipulation and detection of spin polarization) have been demonstrated in semiconductors and spin transistor structures using electrical and optical methods. However, an unsolved challenge is the realization of all-electrical methods to control the spin polarization in a transistor manner at ambient temperatures. Here we combine graphene and molybdenum disulfide (MoS2) in a van der Waals heterostructure to realize a spin field-effect transistor (spin-FET) at room temperature. These two-dimensional crystals offer a unique platform due to their contrasting properties, such as weak spin-orbit coupling (SOC) in graphene and strong SOC in MoS2. The gate-tuning of the Schottky barrier at the MoS2/graphene interface and MoS2 channel yields spins to interact with high SOC material and allows us to control the spin polarization and lifetime. This all-electrical spin-FET at room temperature is a substantial step in the field of spintronics and opens a new platform for testing a plethora of exotic physical phenomena, which can be key building blocks in future device architectures.

  2. Nuclear electric propulsion operational reliability and crew safety study

    International Nuclear Information System (INIS)

    Karns, J.J.; Fragola, J.R.; Kahan, L.; Pelaccio, D.

    1993-01-01

    The central purpose of this analysis is to assess the ''achievability'' of a nuclear electric propulsion (NEP) system in a given mission. ''Achievability'' is a concept introduced to indicate the extent to which a system that meets or achieves its design goals might be implemented using the existing technology base. In the context of this analysis, the objective is to assess the achievability of an NEP system for a manned Mars mission as it pertains to operational reliability and crew safety goals. By varying design parameters, then examining the resulting system achievability, the design and mission risk drivers can be identified. Additionally, conceptual changes in design approach or mission strategy which are likely to improve overall achievability of the NEP system can be examined

  3. The resilience of an operating point for a fusion power plant

    Energy Technology Data Exchange (ETDEWEB)

    Ward, David, E-mail: david.ward@ccfe.ac.uk; Kemp, Richard

    2015-10-15

    Highlights: • The need to control a power plant changes our view of the optimum design. • The need for control can be reduced by finding resilient design points. • It is important to include resilience and control in selecting design points. • Including these additional constraints reduces flexibility in choice of operating points. - Abstract: The operating point for fusion power plant design concepts is often determined by simultaneously satisfying the requirements of all of the main plant systems and finding an optimum solution, for instance the one with the lowest capital cost or cost of electricity. This static assessment takes no account of the sensitivity of that operating point to variations in key parameters and therefore includes no information about how difficult to adjust and control the chosen operating point may be. Control of the operation point is a large subject with much work still to be done, and is expected to play an increasing role in the future in choosing the optimum design point. Here we present results of two analyses: one relates to the ability to load follow, that is, to vary the power production in the light of varying demands for power from the electricity network; the other investigates in simple terms what choices we can make to improve the resilience of static operating points.

  4. Prices on electricity and transmission of electricity

    International Nuclear Information System (INIS)

    2002-01-01

    This publication contains data on prices of electric energy and transmission of electricity valid on 1 January 2002. The purpose is to illustrate the price changes on the electricity market in terms of prices for different customer categories. All companies holding network concessions for areas and all companies trading in electricity are included in this report, which is produced on an annual basis. The prices for transmission services 1 January 2002 were on the whole unchanged compared to the preceding year. For households the mean annual cost was SEK 856 for flats, SEK 4,194 one- or two-family houses with electric heating and SEK 1,881 without electric heating. (1 SEK ∼ 0.1 USD). Electricity prices rose considerably on 1 January 2002 compared to the year before. The mean price per kWh for households according to standard agreement was SEK 0.356 for deliveries to flats, SEK 0.296 for apartments in one- or two-family houses with electric heating and SEK 0.316 without electric heating. That means that the mean annual cost increased by SEK 171 for flats. For one- or two-family houses with electric heating, costs increased by SEK 1,424, and by SEK 379 for those houses without electric heating. The high costs of electricity may be explained in part by the development on the Nordic Power Exchange (Nord Pool), where the spot price increased by 75 per cent during 2001. The price development for household customers during 1996-2002 is shown in a diagram

  5. Electricity costs in liberalized market

    International Nuclear Information System (INIS)

    Barkans, J.; Junghans, G.

    2006-01-01

    In the liberalized electricity market the flexible demand determines the operation of power plants. Under market conditions the producers are forced to compete, and their power plants are normally loaded in order of increasing prices. The electricity costs consist of fixed and variable components, and the competition among producers simulates minimization of both the components. Considering the fixed costs (including maintenance, depreciation, capital costs and other permanent costs not depending on production) to be known, the total electricity costs in different operating conditions are based on the economic characteristics and the equipment load of a power plant. The paper describes the method for determination of electricity costs for condensing thermal power plants with permanent steam take-off for regeneration purposes and adjustable steam take-off for the needs of local heat energy consumers. The marginal costs for CHP plants are determined considering a number of different steam take-off from a turbine. At the electricity cost determination, auxiliary services also are taken into account. These can be reduced by adjusting the rotational speed of electric motors. The paper also shows how to determine the electricity costs for gas turbines, combined cycle gas turbines, and nuclear power plants. The position of hydro power plants among other PPs in the free market is also analysed. (authors)

  6. Electrically pumped all photonic crystal 2nd order DFB lasers arrays emitting at 2.3 μm

    Directory of Open Access Journals (Sweden)

    B. Adelin

    2017-03-01

    Full Text Available Single-mode, widely tunable laser diodes in the mid-infrared range are highly interesting for demanding spectroscopic applications involving multi-species discrimination. We report on an alternative approach using single frequency laser arrays. Single-mode laser arrays were fabricated using all-photonic-crystal electrically pumped distributed feedback cavities on GaSb. The fabricated lasers exhibit thresholds in the 3.2 kA/cm2 range in a continuous wave regime at room temperature. The maximum output power reaches 1 mW and single mode operation with a side-mode suppression ratio of 30 dB is demonstrated. These lasers were used to perform tunable diode laser absorption spectroscopy of several gases in standard gas cells. Continuous spectral coverage of a 40 nm band using 10 lasers seems an achievable goal using laser arrays with PhC lattice constant variations of 1 nm from laser to laser.

  7. Integrated model of port oil piping transportation system safety including operating environment threats

    Directory of Open Access Journals (Sweden)

    Kołowrocki Krzysztof

    2017-06-01

    Full Text Available The paper presents an integrated general model of complex technical system, linking its multistate safety model and the model of its operation process including operating environment threats and considering variable at different operation states its safety structures and its components safety parameters. Under the assumption that the system has exponential safety function, the safety characteristics of the port oil piping transportation system are determined.

  8. Integrated model of port oil piping transportation system safety including operating environment threats

    OpenAIRE

    Kołowrocki, Krzysztof; Kuligowska, Ewa; Soszyńska-Budny, Joanna

    2017-01-01

    The paper presents an integrated general model of complex technical system, linking its multistate safety model and the model of its operation process including operating environment threats and considering variable at different operation states its safety structures and its components safety parameters. Under the assumption that the system has exponential safety function, the safety characteristics of the port oil piping transportation system are determined.

  9. Licensed operating reactors. Operating units status report, data as of 2-28-79

    International Nuclear Information System (INIS)

    1979-03-01

    This report is divided into three sections: the first contains monthly highlights and statistics for commercial operating units, and errata from previously reported data; the second is a compilation of detailed information on each unit, provided by NRC Regional Offices and IE Headquarters; and the third section is an appendix containing comparative statistics of U.S. nuclear/fossil capacity, identification of nuclear power plants within regional Electric Reliability Councils, the relative status of U.S. nuclear electric production to all U.S. electric production by state, and selected Edison Electric Institute operating statistics. Throughout the report, statistical factors for periods greater than a report month, or for more than one unit, are computed as the arithmetic average of each unit's individual operating statistics. The statistical factors for each unit for the report month are computed from actual power production for the month. The factors for the life-span of each unit (the ''Cumulative'' column) are reported by the utility and are not entirely re-computed by NRC. Utility power production data is checked for consistency with previously submitted statistics

  10. The electric power engineering handbook power systems

    CERN Document Server

    2012-01-01

    Power Systems, Third Edition (part of the five-volume set, The Electric Power Engineering Handbook) covers all aspects of power system protection, dynamics, stability, operation, and control. Under the editorial guidance of L.L. Grigsby, a respected and accomplished authority in power engineering, and section editors Andrew Hanson, Pritindra Chowdhuri, Gerry Sheble, and Mark Nelms, this carefully crafted reference includes substantial new and revised contributions from worldwide leaders in the field. This content provides convenient access to overviews and detailed information on a diverse arr

  11. Electric sales and revenue: 1993

    Energy Technology Data Exchange (ETDEWEB)

    1995-01-01

    The Electric Sales and Revenue is prepared by the Survey Management Division, Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); US Department of Energy. This publication provides information about sales of electricity, its associated revenue, and the average revenue per kilowatthour sold to residential, commercial, industrial, and other consumers throughout the United States. The sales, revenue, and average revenue per kilowatthour data provided in the Electric Sales and Revenue are based on annual data reported by electric utilities for the calendar year ending December 31, 1993. Operating revenue includes energy charges, demand charges, consumer service charges, environmental surcharges, fuel adjustments, and other miscellaneous charges. The revenue does not include taxes, such as sales and excise taxes, that are assessed on the consumer and collected through the utility. Average revenue per kilowatthour is defined as the cost per unit of electricity sold and is calculated by dividing retail sales into the associated electric revenue. Because electric rates vary based on energy usage, average revenue per kilowatthour are affected by changes in the volume of sales. The sales of electricity, associated revenue, and average revenue per kilowatthour data provided in this report are presented at the national, Census division, State, and electric utility levels.

  12. The long road back for a reborn Philadelphia Electric

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    On 31 March 1987, the US NRC ordered Philadelphia Electric to shut down its Peach Bottom BWR station because of operator inattentiveness. Since then Philadelphia Electric has undergone the most complete transformation of corporate and nuclear management of any US utility. Everyone in direct line supervision was replaced, from the chairman of the board down to shift supervisors. Nuclear operations were completely reorganized and a dedicated nuclear group formed. Procedures were rewritten and operator training and career development upgraded. Plant maintenance and housekeeping have been raised to new levels of excellence. It has been a long road back for Philadelphia Electric. But all major goals are now being met and a corporate culture is being developed focused on excellence in nuclear operations. (author)

  13. Manitoba plug-in hybrid electric vehicle (PHEV) demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Hoemsen, R. [Red River College, Winnipeg, MB (Canada); Parsons, R. [Government of Manitoba, Winnipeg, MB (Canada). Centre for Emerging Renewable Energy

    2010-07-01

    Manitoba has low electricity rates, the highest proportion of renewables, and a legislated commitment to reduce greenhouse gases. However, the province still relies heavily on oil as everyone else. The mix of energy opportunities in Manitoba were highlighted in this presentation, with particular reference to the commercialization of electric vehicles. Several photographs were presented of the Toyota plug-in hybrid vehicle and a plug-in hybrid electric demonstration vehicle. A demonstration project overview was offered that used technology from A123 Systems Inc. The conversion module and vehicle users were profiled. Topics that were presented related to the demonstration project included monitoring; gasoline fuel economy results; fuel economy variability; cold weather operation; cold weather issues; battery upgrade solutions; and highly qualified personnel. It was concluded that in terms of follow-up, there is a need to combine findings of current plug-in hybrid electric vehicle demonstration with those for the new Toyota production plug-in hybrid vehicles. Key next steps for the demonstration are to address cabin heating requirements; better characterizing winter performance; and implementation of IPLC units on all plug-in hybrid electric vehicles for electricity consumption. figs.

  14. Large A.C. machines theory and investigation methods of currents and losses in stator and rotor meshes including operation with nonlinear loads

    CERN Document Server

    Boguslawsky, Iliya; Hayakawa, Masashi

    2017-01-01

    In this monograph the authors solve the modern scientific problems connected with A.C. motors and generators, based first on the detailed consideration of their physical phenomena. The authors describe the theory and investigative methods they developed and applied in practice, which are considered to be of essential interest for specialists in the field of the electrical engineering industry in European countries, the USA, Argentina, and Brazil, as well as in such countries as India, China, and Iran. This book will be of interest to engineers specialized in the field of the manufacture, operation, and repair of A.C. machines (motors and generators) as well as electric drives; to professors, lecturers, and post-graduate students of technical universities, who are specializing in the field of electric machine engineering and electric drives; and to students who are engaged in the field of high current techniques, electric drives, and electric machine engineering.

  15. Comparison of all-remote and personnel access maintenance operations for INTOR

    International Nuclear Information System (INIS)

    Spampinato, P.T.; Finn, P.A.; Gohar, M.Y.; Stasko, R.R.

    1985-01-01

    The INTOR reference design was developed to permit limited maintenance operations external to the reactor in a ''hands-on'' mode; all internal operations would be remotely accomplished. The design embodies those requirements for shielding, tritium containment and cleanup, and confinement of contaminated particulate matter to permit personnel access. The cost reflects these requirements, at least first order. The impact of personnel access on the reactor design and its costs are cause to reexamine the maintenance approach on which much of the present configuration is based. The purpose of this study is to compare the benefits and costs associated with personnel access maintenance procedures to those associated with all-remote maintenance procedures and to identify modifications to the baseline design that could enhance maintenance operations

  16. The evolution of the status of local electric and gas utilities in a competitive environment

    International Nuclear Information System (INIS)

    Nivault, S.

    2004-06-01

    With the establishment of a common gas and electricity market, the early 21. century is marked by important transformations in the public energy service. Directives 96/92 and 98/30, and directives 2003/54 and 2003/55, make important changes in the regulations concerning gas and electricity activates. In France, the Electricity Act 2000 (10/02/2000) and the Gas Act 2003 (03/01/2003) partially opened the public sector power distribution system to competition. These new rules will drastically modify all operators situations, including that of french local distributors (such as the 'regies', the 'SEML', or the 'SICAE or other cooperatives') who have always been, since being left out of the nationalization process, in a monopolistic situation. In order to succeed in the transition towards a free market economy, french local distributors will have to evolve from their network operator status to that of market operator by renewing their structural organisation and diversifying their activities. (author)

  17. CALCULATION OF A MECHANICAL CHARACTERISTIC OF ELECTRIC TRACTION MOTOR OF ELECTRIC VEHICLE

    Directory of Open Access Journals (Sweden)

    Phuong Le Ngo

    2017-01-01

    Full Text Available The traction characteristic of an electric vehicle is the main characteristic of mechanical system that reflects its key performance indicators. Implementation of the traction characteristic is based on controlling angular speed and torque of electric traction motor in an automatic control system. The static mechanical characteristic of an electric traction motor in an automatic control system is the most important characteristic that determines weight, size and operating characteristics of an electric traction motor and serves as the basis for design. The most common variants of constructive implementation of a traction electric drive are analyzed, and a scheme is chosen for further design. Lagrange’s equation for electric mechanical system with one degree of freedom is written in generalized coordinates. In order to determine the generalized forces, elementary operation of all moments influencing on a moving car has been calculated. The resulting equation of motion of the electric vehicle corresponding to the design scheme, as well as the expressions for calculation of characteristic points of static mechanical characteristics of traction motor (i.e. the maximum and minimum time, minimum power are obtained. In order to determine the nominal values of the angular velocity and the power of electric traction motor, a method based on ensuring the movement of the vehicle in the standard cycle has been developed. The method makes it possible to calculate characteristic points of the mechanical characteristic with the lowest possible power rating. The algorithm for calculation of mechanical characteristics of the motor is presented. The method was applied to calculate static mechanical characteristic of an electric traction motor for a small urban electric truck.

  18. Independent operation by subsystems: Strategic behavior for the Brazilian electricity sector

    International Nuclear Information System (INIS)

    Guido Tapia Carpio, Lucio; Olimpio Pereira, Amaro

    2006-01-01

    This article describes the competitive strategies of the subsystems in the Brazilian electricity sector. The objective is to present a model in which the operation of each subsystem is managed independently. As the subsystems correspond to the country's geographic regions, the adoption of this model creates conditions for each region to develop according to its own peculiarities. The decision-making process is described based Game Theory. As such, the players or operators of each subsystem carry out their strategies based on the quantities produced, which results in Nash-Cournot equilibrium. In this model, the importance of the proper transmission line dimensioning is highlighted. It determines the competition level among subsystems and allows for optimization of the whole system without requiring arrangements for managing the congestion of the energy transportation grid. The model was programmed in FORTRAN, using IBM's optimization subroutine library (OSL) package

  19. All-electric tourist hotel Hoch-Ybrig in the Schwyz canton

    Energy Technology Data Exchange (ETDEWEB)

    Kaelin, W

    1976-11-01

    The article deals mainly with questions relating to the heating of the all-electric Hoch-Ybrig tourist hotel in the Schwyz canton of Switzerland. Situated at an altitude of around 1,500 m above sea level, the hotel is exposed to severe climatic conditions and heated mainly with storage and direct heaters. A number of separate rooms, however, such as restaurant, kitchen, garage, workshops and ancillary rooms, are ventilated by a system combined with Econovent heat recovery units. The heat recovery system saves about 74% of the energy required annually for heating these spaces. The balance is supplied by a central heat store. The design of the heat-recovery system is explained in detail.

  20. An environment for operation planning of electrical energy distribution systems; Um ambiente para planejamento da operacao de sistemas de distribuicao de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Kleber

    1997-07-01

    The aim of operation planning of electrical energy distribution systems is to define a group of interventions in the distribution network in a way to reach a global optimization. Both normal operation and emergency conditions are considered including scheduled interventions in the network. Under normal conditions, some aspects as voltage drop and loss minimization, for example, are considered; under emergency conditions, the minimization of non-distributed energy and interruption time are taken into account. This proposes the development of a computer environment for operation planning studies. The design and implementation of a specific operation planning database, based on a relational database model, was carried out so that new information modules could be easily included. A statistical approach has been applied to the load model including consumption habits and seasonal information, for each consumer category. A group of operation planning functions is proposed, which includes simulation modules responsible for system analysis. These functions and the database should be designed together. The developed computer environment allows the inclusion of new functions, due to the standardized query language used to access the database. Two functions have been implemented for illustration. The development of the proposed environment constitutes a step towards an open operation planning system, an integration with other information systems and an easy-to-use system based on graphical interface. (author)

  1. General Electric : Immelt surve all / Jena McGregor

    Index Scriptorium Estoniae

    McGregor, Jena

    2008-01-01

    Ettevõtte General Electric juht Jeffrey R. Immelt võitleb selle nimel, et taastada usaldus firma vastu, kuna laenukriis ja kehvad aktsiahinnad on tekitanud olukorra, kus investorid avaldavad suurt survet ettevõtte juhile. Lisa: GE kindralid

  2. Optimal scheduling for vehicle-to-grid operation with stochastic connection of plug-in electric vehicles to smart grid

    International Nuclear Information System (INIS)

    Jian, Linni; Zheng, Yanchong; Xiao, Xinping; Chan, C.C.

    2015-01-01

    Highlights: • A novel event-triggered scheduling scheme for vehicle-to-grid (V2G) operation is proposed. • New scheme can handle the uncertainty arising from stochastic connection of electric vehicles. • New scheme aims at minimizing the overall load variance of power grid by V2G operation. • Method to evaluate the performance of proposed scheme is elaborated and demonstrated. - Abstract: Vehicle-to-grid (V2G) operation of plug-in electric vehicles (PEVs) is attracting increasing attention since it can assist to improve the efficiency and reliability of power grid, as well as reduce the operating cost and greenhouse gas emission of electric vehicles. Within the scheme of V2G operation, PEVs are expected to serve as a novel distributed energy storage system (ESS) to help achieve the balance between supply and demand of power grid. One of the key difficulties concerning its practical implementation lies in that the availability of PEVs as ESS for grid remains highly uncertain due to their mobility as transportation tools. To address this issue, a novel event-triggered scheduling scheme for V2G operation based on the scenario of stochastic PEV connection to smart grid is proposed in this paper. Firstly, the mathematical model is formulated. Secondly, the preparation of input data for systematic evaluation is introduced and the case study is conducted. Finally, statistic analysis results demonstrate that our proposed V2G scheduling scheme can dramatically smooth out the fluctuation in power load profiles

  3. Operation without benefit in the services sector

    International Nuclear Information System (INIS)

    Brunner, C. U.; Nipkow, J.; Brechbuehl, B.; Glauser, H.; Steinemann, U.

    2009-01-01

    This final report for the Swiss Federal Office of Energy (SFOE) discusses the unnecessary operation of electrical equipment. This preliminary study examined in a top-down manner the electrical grid loads at night in Switzerland and attempts to identify unnecessary loads. The results of a bottom-up analysis of seven buildings in the service sector was made. One large complex was also used to identify the sources of night-time loads. Together, these two approaches allowed a first appreciation and a rough quantification of the load caused by the unnecessary operation of equipment in the Swiss electricity grid. The services sector has an estimated share of some 2.4 TWh/a caused by unnecessary operation. In a follow-up project the reduction of unnecessary loads is to be studied in more detail. This second analysis will also have to include loads caused by unnecessary operation during the daytime. The goal of the project is eventually to reduce any unnecessary electric loads and, as a result, the entire electricity demands of Switzerland

  4. Introduction to the Control of Electric Motors.

    Science.gov (United States)

    Spencer, Frederick

    The fundamentals of electric circuits and electric machines are presented in the text, with an emphasis on the practical operation rather than on mathematical analyses of theories involved. The material contained in the text includes the fundamentals of both D.C. and A.C. circuits together with the principles of magnetism and electro-magnetic…

  5. DETERMINATION OF THE RESIDUAL OPERATING TIME OF UNRESTORABLE ELEMENT OF THE ELECTRIC POWER OBJECT AT THE WAYBALL DISTRIBUTION

    International Nuclear Information System (INIS)

    Namgaladze, D.; Gurgenidze, D.

    2007-01-01

    In practice, it is often essential to determinethe residual operating time for an unrestorable element of the electric power object which has operated without failure for a certain time. The density of probability distribution of operating time can be determined from the initial probability distribution of operating time. In this work, the relations for determination of the function of residual operating time of the unrestorable element at the exponential and Wayball distributions are analytically derived. (author)

  6. Front-Line Resilience Perspectives: The Electric Grid

    Energy Technology Data Exchange (ETDEWEB)

    Finster, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Phillips, J. [Argonne National Lab. (ANL), Argonne, IL (United States); Wallace, K. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-11-01

    This report seeks to summarize how states and local utility companies are approaching all-hazards resilience in planning, construction, operations, and maintenance of the electric system, as well as challenges faced when addressing all-hazards resilience.

  7. Consolidating Learning in Power Systems: Virtual Reality Applied to the Study of the Operation of Electric Power Transformers

    Science.gov (United States)

    Barata, Pebertli Nils Alho; Filho, Manoel Ribeiro; Nunes, Marcus V. Alves

    2015-01-01

    Within the field of electric power systems, the study of electrical equipment can be frustrating and demotivating because of the lack of a clear vision of how this equipment functions and operates in a real environment. The use of virtual reality can provide a more concrete representation for students, who rarely have the opportunity to visit a…

  8. 75 FR 11920 - General Electric Lighting-Ravenna Lamp Plant, Lighting Division, Including On-Site Leased Workers...

    Science.gov (United States)

    2010-03-12

    ... to the production of high intensity discharge lamps. The review shows that on August 24, 2007, a...-Ravenna Lamp Plant, Lighting Division, Including On-Site Leased Workers from Devore Technologies, Ravenna..., 2009, applicable to workers of General Electric Lighting-Ravenna Lamp Plant, Lighting Division...

  9. Economic analysis of electric heating based on critical electricity price

    Science.gov (United States)

    Xie, Feng; Sun, Zhijie; Zhou, Xinnan; Fu, Chengran; Yang, Jie

    2018-06-01

    The State Grid Corporation of China proposes an alternative energy strategy, which will make electric heating an important task in the field of residential electricity consumption. This article takes this as the background, has made the detailed introduction to the inhabitant electric heating technology, and take the Zhangjiakou electric panels heating technology as an example, from the expense angle, has carried on the analysis to the electric panels heating economy. In the field of residential heating, electric panels operating costs less than gas boilers. After customers implying energy-saving behavior, electric panels operating cost is even lower than coal-fired boilers. The critical price is higher than the execution price, which indicates that the economic performance of the electric panels is significantly higher than that of the coal boiler.

  10. Electricity Markets Ontology to Support MASCEM's Simulations

    DEFF Research Database (Denmark)

    Santos, Gabriel; Pinto, Tiago; Vale, Zita

    2016-01-01

    the several issues related to these systems, including the involved players that act in this domain. To take better advantage of these systems, their integration is mandatory. The main contribution of this paper is the development of the Electricity Markets Ontology, which integrates the essential concepts...... necessary to interpret all the available information related to electricity markets, while enabling an easier cooperation and adequate communication between related systems. Additionally, the concepts and rules defined by this ontology can be extended and complemented according to the needs of other......Power systems worldwide are complex and challenging environments. The increasing necessity for an adequate integration of renewable energy sources is resulting in a rising complexity in power systems operation. Multi-agent based simulation platforms have proven to be a good option to study...

  11. The electricity grid as a marketplace. Mannheim tests virtual energy market for generators, consumers and grid operators; Das Stromnetz wird zum Marktplatz. Mannheim erprobt virtuellen Energiemarkt fuer Erzeuger, Verbraucher und Netzbetreiber

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, Uwe

    2011-07-01

    In future, electricity grids will have to transport large quantities of electricity from renewable energy sources fed centrally and decentrally. Plus, we need greater reserves, storage facilities and flexibility in the electricity market due to the fluctuating supply. In the ''Modellstadt Mannheim'' project, a virtual energy marketplace is being developed for energy generators, consumers and grid operators. Customers can see the source and price of their electricity and influence them directly via the timing and extent of their consumption and the delivery from their own generation systems. This approach also includes gas, water and district heating. (orig.)

  12. Unification of all elementary-particle forces including gravity

    International Nuclear Information System (INIS)

    Terazawa, Hidezumi; Chikashige, Yuichi; Matsuki, Takayuki; Akama, Keiichi.

    1978-07-01

    A unified model of the Nambu-Jona-Lasinio type for all elementary-particle forces including gravity is reviewed in some detail. Starting with a nonlinear fermion Lagrangian of the Heisenberg type and imposing the massless conditions of Bjorken on vector auxiliary fields, on effective Lagrangian is constructed, which combines the unified SU (2) x U (1) gauge theory of Weinberg and Salam for the weak and electromagnetic interactions of leptons and quarks and the Yang-Mills gauge theory of color SU (3) for the strong interaction of quarks. The photon, the weak vector bosons, and the physical Higgs scalar appear as collective excitations of lepton-antilepton or quark-antiquark pairs while the color-octet gluons appear as those of quark-antiquark pairs. The most important results of this unified model are presented. The Weinberg angle and the gluon coupling constant are determined, and the masses of the weak vector bosons are predicted. (Yoshimori, M.)

  13. New Brunswick System Operator 2005 annual report

    International Nuclear Information System (INIS)

    2005-01-01

    New Brunswick's electricity generating mix includes thermal, hydro and nuclear power. Facts about New Brunswick's electricity market were presented with reference to transmission lines; number of interconnecting operators; interconnection capacity; installed generation capacity; generation capacity mix; peak demand for 2004-2005; total energy transactions over a 6 month period and value of electricity over that 6 month period. The independently governed New Brunswick System Operator (NBSO) began operations in 2004 with a mandate to introduce competitive integrated electricity supply to municipal utilities and large industrial customers in order to ensure a reliable and adequate supply of electricity to the Maritime area. The NBSO's first task to launch the transition from monopoly supply to a competitive market is in the beginning stages, but progress has been made in terms of market rules, new computerized systems, and consultations with the Market Advisory Committee who review potential changes to the market rules and tariffs. tabs., figs

  14. All-electric-controlled spin current switching in single-molecule magnet-tunnel junctions

    Science.gov (United States)

    Zhang, Zheng-Zhong; Shen, Rui; Sheng, Li; Wang, Rui-Qiang; Wang, Bai-Gen; Xing, Ding-Yu

    2011-04-01

    A single-molecule magnet (SMM) coupled to two normal metallic electrodes can both switch spin-up and spin-down electronic currents within two different windows of SMM gate voltage. Such spin current switching in the SMM tunnel junction arises from spin-selected single electron resonant tunneling via the lowest unoccupied molecular orbit of the SMM. Since it is not magnetically controlled but all-electrically controlled, the proposed spin current switching effect may have potential applications in future spintronics.

  15. NRC Information No. 89-63: Possible submergence of electrical circuits located above the flood level because of water intrusion and lack of drainage

    International Nuclear Information System (INIS)

    Rossi, C.E.

    1992-01-01

    This information notice is being provided to alert addressees that electrical circuits located above the plant flood level within electrical enclosures may become submerged in water because appropriate drainage has not been provided. Failure of electrical circuits during service conditions, including postulated accidents, can occur due to submergence if water enters these enclosures and there is no provision for drainage. The electrical enclosures addressed by this notice include terminal boxes, junction boxes, pull boxes, conduits, Condulets, and other enclosures for end-use equipment (such as limit switches, motor operators, and electrical penetrations), the contents of which may include cables, terminal blocks, electrical splices and connectors. Information Notice 84-57, ''Operating Experience Related to Moisture Intrusion on Safety-Related Electrical Equipment at Commercial Power Plants,'' addressed watertight sealing of all electrical conduits to junction boxes and conduit-to-terminal box connection points for safety-related equipment located in areas of the reactor building as well as for areas that are potentially subject to high temperature steam or water impingement. This notice further addressed the importance of ensuring that box drain holes and equipment interfaces are in conformance with the test setup established during equipment qualification testing and with the vendor's recommendations

  16. Spine surgeon's kinematics during discectomy, part II: operating table height and visualization methods, including microscope.

    Science.gov (United States)

    Park, Jeong Yoon; Kim, Kyung Hyun; Kuh, Sung Uk; Chin, Dong Kyu; Kim, Keun Su; Cho, Yong Eun

    2014-05-01

    Surgeon spine angle during surgery was studied ergonomically and the kinematics of the surgeon's spine was related with musculoskeletal fatigue and pain. Spine angles varied depending on operation table height and visualization method, and in a previous paper we showed that the use of a loupe and a table height at the midpoint between the umbilicus and the sternum are optimal for reducing musculoskeletal loading. However, no studies have previously included a microscope as a possible visualization method. The objective of this study is to assess differences in surgeon spine angles depending on operating table height and visualization method, including microscope. We enrolled 18 experienced spine surgeons for this study, who each performed a discectomy using a spine surgery simulator. Three different methods were used to visualize the surgical field (naked eye, loupe, microscope) and three different operating table heights (anterior superior iliac spine, umbilicus, the midpoint between the umbilicus and the sternum) were studied. Whole spine angles were compared for three different views during the discectomy simulation: midline, ipsilateral, and contralateral. A 16-camera optoelectronic motion analysis system was used, and 16 markers were placed from the head to the pelvis. Lumbar lordosis, thoracic kyphosis, cervical lordosis, and occipital angle were compared between the different operating table heights and visualization methods as well as a natural standing position. Whole spine angles differed significantly depending on visualization method. All parameters were closer to natural standing values when discectomy was performed with a microscope, and there were no differences between the naked eye and the loupe. Whole spine angles were also found to differ from the natural standing position depending on operating table height, and became closer to natural standing position values as the operating table height increased, independent of the visualization method

  17. MSFC Skylab electrical power systems mission evaluation

    Science.gov (United States)

    Woosley, A. P.

    1974-01-01

    The design, development, and operation of the Skylab electrical power system are discussed. The electrical systems for the airlock module of the orbital workshop and the Apollo telescope mount are described. Skylab is considered an integral laboratory, however, both cluster and module hardware distinct sections are included. Significant concept and requirement evolution, testing, and modifications resulting from tests are briefly summarized to aid in understanding the launch configuration description and the procedures and performance discussed for in-orbit operation. Specific problems encountered during Skylab orbital missions are analyzed.

  18. Modeling water resources as a constraint in electricity capacity expansion models

    Science.gov (United States)

    Newmark, R. L.; Macknick, J.; Cohen, S.; Tidwell, V. C.; Woldeyesus, T.; Martinez, A.

    2013-12-01

    In the United States, the electric power sector is the largest withdrawer of freshwater in the nation. The primary demand for water from the electricity sector is for thermoelectric power plant cooling. Areas likely to see the largest near-term growth in population and energy usage, the Southwest and the Southeast, are also facing freshwater scarcity and have experienced water-related power reliability issues in the past decade. Lack of water may become a barrier for new conventionally-cooled power plants, and alternative cooling systems will impact technology cost and performance. Although water is integral to electricity generation, it has long been neglected as a constraint in future electricity system projections. Assessing the impact of water resource scarcity on energy infrastructure development is critical, both for conventional and renewable energy technologies. Efficiently utilizing all water types, including wastewater and brackish sources, or utilizing dry-cooling technologies, will be essential for transitioning to a low-carbon electricity system. This work provides the first demonstration of a national electric system capacity expansion model that incorporates water resources as a constraint on the current and future U.S. electricity system. The Regional Electricity Deployment System (ReEDS) model was enhanced to represent multiple cooling technology types and limited water resource availability in its optimization of electricity sector capacity expansion to 2050. The ReEDS model has high geographic and temporal resolution, making it a suitable model for incorporating water resources, which are inherently seasonal and watershed-specific. Cooling system technologies were assigned varying costs (capital, operations and maintenance), and performance parameters, reflecting inherent tradeoffs in water impacts and operating characteristics. Water rights supply curves were developed for each of the power balancing regions in ReEDS. Supply curves include costs

  19. ANALYSIS OF ENERGY EFFICIENCY OF OPERATING MODES OF ELECTRICAL SYSTEMS WITH THE TRACTION LOADS

    Directory of Open Access Journals (Sweden)

    V. E. Bondarenko

    2017-03-01

    Full Text Available Innovative scenarios of reliable energy supply of transportation process aimed at reducing the specific energy consumption and increase energy efficiency of the systems of electric traction. The paper suggests innovative energy saving directions in traction networks of railways and new circuit solutions accessing traction substations in energy systems networks, ensure energy security of the transportation process. To ensure the energy security of rail transport special schemes were developed to propose the concept of external power traction substations, which would increase the number of connections to the networks of 220 – 330 kV, as well as the creation of transport and energy corridors, development of its own supply of electric networks of 110 kV substations and mobile RP-110 kV of next generation. Therefore, the investment program of the structures owned by the Ukrainian Railways (Ukrzaliznytsia need to be synchronized in their technological characteristics, as well as the criteria of reliability and quality of power supply with the same external energy investment programs. It is found that without any load on left or right supplying arm one of two less loaded phases of traction transformer begins generating specific modes in the supplying three-phase line. Thus, modes of mobile substation cause leakage in one of the phases of the supply line of traction transformers of active-capacitive current, and as a result generating energy in the main power line of 154 kV, which is fixed and calculated by electricity meters. For these three phase mode supply network is necessary to use 1st algorithm, i.e. taking into account the amount of electricity as the energy in all phases. For effective application of reactive power compensation devices in the AC traction power supply systems it is proposed to develop regulatory documentation on necessity of application and the order of choice of parameters and placement of compensation systems taking into

  20. Automated complex for research of electric drives control

    Science.gov (United States)

    Avlasko, P. V.; Antonenko, D. A.

    2018-05-01

    In the article, the automated complex intended for research of various control modes of electric motors including the inductor motor of double-way feed is described. As a basis of the created complex, the National Instruments platform is chosen. The operating controller built in a platform is delivered with an operating system of real-time for creation of systems of measurement and management. The software developed in the environment of LabVIEW consists of several connected modules which are in different elements of a complex. Besides the software for automated management by experimental installation, the program complex is developed for modelling of processes in the electric drive. As a result there is an opportunity to compare simulated and received experimentally transitional characteristics of the electric drive in various operating modes.

  1. Open-Ended Electric Motor

    Science.gov (United States)

    Gould, Mauri

    1975-01-01

    Presents complete instructions for assembling an electric motor which does not require large amounts of power to operate and which is inexpensive as well as reliable. Several open-ended experiments with the motor are included as well as information for obtaining a kit of parts and instructions. (BR)

  2. Batteries for Electric Vehicles

    Science.gov (United States)

    Conover, R. A.

    1985-01-01

    Report summarizes results of test on "near-term" electrochemical batteries - (batteries approaching commercial production). Nickel/iron, nickel/zinc, and advanced lead/acid batteries included in tests and compared with conventional lead/acid batteries. Batteries operated in electric vehicles at constant speed and repetitive schedule of accerlerating, coasting, and braking.

  3. How the physical electricity markets will work in Ontario

    International Nuclear Information System (INIS)

    Murphy, P.

    1998-01-01

    The issue of how the physical electricity markets in Ontario will operate was the focus of this presentation. Principal topics addressed included a definition of the physical market, (a mechanism through which the terms and conditions, including price, for the physical exchange of a commodity are established, and delivery is realized); a discussion on the role of the Independent Market Operator; wholesale and retail electricity markets; retail market proposals; the staging of congestion pricing; and the life cycle of physical transactions and payments. Market price components were summarized, and a typical transaction from bids and offers to billing and fund transfer was illustrated

  4. THE TRACTION ELECTRIC OPERATION AND ITS EXPLOITATION ABILITIES

    Directory of Open Access Journals (Sweden)

    V. M. Bezruchenko

    2011-04-01

    Full Text Available The possibilities of asynchronous traction electric motor drive are considered at the certain coupling mass taking into account the coupling restrictions. A variant of using the regulation law for electric motor drive allowing realizing traction force more rationally is offered. The possibility of reaching the speeds to 220 km/h for electric locomotive DS3 is shown

  5. Electric power plant international. 1976--1977 edition

    Energy Technology Data Exchange (ETDEWEB)

    1975-01-01

    ''Electric Power Plant International'' is intended to provide a comprehensive commercial and technical information source for use by suppliers, operators, and potential purchasers of power plant, and also by suppliers of materials and services to such organizations. It contains information that will help those considering the purchase of power plant to gain a reasonable understanding of the factors that should be taken into account when making a purchasing decision. Consideration is given to the operation, maintenance, and modification of power systems that will be of relevance to those currently operating plant. The publication is designed to act as an interface between suppliers and users of power plant. As part of this function, reference sections contain listings of all the companies that have been located throughout the world, supplying prime movers, generators, generator sets, and fixed-frequency inverter systems. Details of products currently available from these companies are included wherever possible and this is being continuously up-dated and extended to give increased coverage in future editions. The Electrical Research Association Ltd. does not manufacture or supply power plant (apart from some special-purpose static inverter systems), but would be pleased to receive requirement details from any company wishing to inquire about plant purchase. These will be forwarded to appropriate suppliers throughout the world who will be able to submit tenders for suitable products. Inquiry forms are included in Chapter 6 for this purpose.

  6. Potential oxidative stress in the bodies of electric arc welding operators: effect of photochemical smog.

    Science.gov (United States)

    Zhu, You-Gen; Zhou, Jun-Fu; Shan, Wei-Ying; Zhou, Pei-Su; Tong, Gui-Zhong

    2004-12-01

    To investigate whether photochemical smog emitted during the process of electric arc welding might cause oxidative stress and potential oxidative damage in the bodies of welding operators. Seventy electric arc welding operators (WOs) and 70 healthy volunteers (HVs) were enrolled in a randomized controlled study design, in which the levels of vitamin C (VC) and vitamin E (VE) in plasma as well as the activities of superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GPX), and the level of lipoperoxide (LPO) in erythrocytes were determined by spectrophotometry. Compared with the average values of the above experimental parameters in the HVs group, the average values of VC and VE in plasma as well as those of SOD, CAT and GPX in erythrocytes in the WOs group were significantly decreased (P smog the values of VC, VE, SOD, and GPX, except for CAT, in the WOs were decreased gradually (P smog in the bodies of WOs, thereby causing potential oxidative and lipoperoxidative damages in their bodies.

  7. 14 CFR 121.639 - Fuel supply: All domestic operations.

    Science.gov (United States)

    2010-01-01

    ... nontransport category airplanes type certificated after December 31, 1964, to fly for 30 minutes at normal... § 121.639 Fuel supply: All domestic operations. No person may dispatch or take off an airplane unless it has enough fuel— (a) To fly to the airport to which it is dispatched; (b) Thereafter, to fly to and...

  8. Network effects in the operation of electrical equipment; Efectos de la red en la operacion del equipo electrico

    Energy Technology Data Exchange (ETDEWEB)

    Garcia T, Arturo; Rosales S, Inocente; Garcia P, Job; Ruiz F, L. Ivan; Robles P, Edgar [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2005-07-01

    In the nineties, the Instituto de Investigaciones Electricas (IIE) Electrical Equipment Management (GEE) was restricted to make the diagnosis of generators, transformers, switch boards and cables, without considering the global operating conditions. With the experience acquired in different services it was verified that, inclusively when this equipment is correctly designed, it can be subjected to unfavorable operative conditions, which causes an accelerated deterioration to the degree of producing a fault. In agreement with this, the GEE settled down new line of development named Analysis of the network effect on the electrical equipment, that analyzes the behavior of the equipment originated by work abnormal causes, including the network configuration effect. [Spanish] En la decada de los noventa, la Gerencia de Equipos Electricos (GEE) del IIE se limitaba a realizar el diagnostico de generadores, transformadores, tableros de distribucion y cables, sin considerar las condiciones globales de operacion. Con la experiencia adquirida en diferentes servicios se comprobo que, inclusive cuando estos equipos esten correctamente disenados, pueden verse sometidos a condiciones de operacion desfavorables, lo que ocasiona un deterioro acelerado al grado de producir una falla. De acuerdo con esto, la GEE establecio una nueva linea de desarrollo de nominada Analisis del efecto de la red en los equipos electricos, que analiza el comportamiento de los equipos originado por causas anormales de trabajo, incluido el efecto de la configuracion de la red.

  9. Femtosecond all-polarization-maintaining fiber laser operating at 1028 nm

    DEFF Research Database (Denmark)

    Olsson, R.K.; Andersen, T.V.; Leick, Lasse

    2008-01-01

    We present an effective solution for an all-polarization-maintaining modelocked femtosecond fiber laser operating at the central wavelength of 1028 nm. The laser is based on an Yb-doped active fiber. Modelocking is enabled by a semiconductor saturable absorber mirror, and the central wavelength i...... is enforced by a fiber Bragg grating. The laser is self-starting and demonstrates excellent stability gainst Q-switching. Pulse energies reach 13 nJ at 34 MHz repetition rate. External compression leads to near transform-limited pulses of 140 fs.......We present an effective solution for an all-polarization-maintaining modelocked femtosecond fiber laser operating at the central wavelength of 1028 nm. The laser is based on an Yb-doped active fiber. Modelocking is enabled by a semiconductor saturable absorber mirror, and the central wavelength...

  10. Straight and chopped DC performance data for a General Electric 5BY436A1 DC shunt motor with a General Electric EV-1 controller

    Science.gov (United States)

    Edie, P. C.

    1981-01-01

    Both straight and chopped dc motor performance data for a General Electric 5BY436A1 motor with a General Electric EV-1 controller is presented in tabular and graphical formats. Effects of motor temperature and operating voltage are also shown. The maximum motor efficiency is approximately 85% at low operating temperatures in the straight dc mode. Chopper efficiency can be assumed to be 95% under all operating conditions. For equal speeds, the motor operated in the chopped mode develops slightly more torque and draws more current than it does in the straight mode.

  11. Assembly for electrical conductivity measurements in the piston cylinder device

    Science.gov (United States)

    Watson, Heather Christine [Dublin, CA; Roberts, Jeffrey James [Livermore, CA

    2012-06-05

    An assembly apparatus for measurement of electrical conductivity or other properties of a sample in a piston cylinder device wherein pressure and heat are applied to the sample by the piston cylinder device. The assembly apparatus includes a body, a first electrode in the body, the first electrode operatively connected to the sample, a first electrical conductor connected to the first electrode, a washer constructed of a hard conducting material, the washer surrounding the first electrical conductor in the body, a second electrode in the body, the second electrode operatively connected to the sample, and a second electrical conductor connected to the second electrode.

  12. Compound induction electric rotating machine

    Energy Technology Data Exchange (ETDEWEB)

    Decesare, D

    1987-07-28

    The present invention generally relates to dynamo-electric machines cabable of operating in a generator mode or in a motor mode and more specifically, to increased efficiency compound interaction AC and/or DC dynamo-electric machines. This patent describes such a machine having a distributed armature winding in a cylindrical rotor wound to form axial and substantially radial winding portions and including permanent and/or electromagnets to couple magnetic flux into the peripheral or circumferential surface of the rotor, and to provide interaction between a magnetic field formed beyond the rotor axial surfaces and the rotor to thereby enhance the total induction of flux into the rotor for improved, more efficient operation. 28 figs.,

  13. Optimal Charging of Electric Vehicles with Trading on the Intraday Electricity Market

    Directory of Open Access Journals (Sweden)

    Ilham Naharudinsyah

    2018-06-01

    Full Text Available Trading on the energy market is a possible way to reduce the electricity costs of charging electric vehicles at public charging stations. In many European countries, it is possible to trade electricity until shortly before the period of delivery on so called intraday electricity markets. In the present work, the potential for reducing the electricity costs by trading on the intraday market is investigated using the example of the German market. Based on simulations, the authors reveal that by optimizing the charging schedule together with the trading on the intraday electricity market, the costs can be reduced by around 8% compared to purchasing all the required energy from the energy supplier. By allowing the charging station operator to resell the energy to the intraday electricity market, an additional cost reduction of around 1% can be achieved. Besides the potential cost savings, the impacts of the trading unit and of the lead time of the intraday electricity market on the costs are investigated. The authors reveal that the achievable electricity costs can be strongly affected by the lead time, while the trading unit has only a minor effect on the costs.

  14. The electric power engineering handbook electric power transformer engineering

    CERN Document Server

    Harlow, James H

    2012-01-01

    Electric Power Transformer Engineering, Third Edition expounds the latest information and developments to engineers who are familiar with basic principles and applications, perhaps including a hands-on working knowledge of power transformers. Targeting all from the merely curious to seasoned professionals and acknowledged experts, its content is structured to enable readers to easily access essential material in order to appreciate the many facets of an electric power transformer.Topically structured in three parts, the book: * Illustrates for electrical engineers the relevant theories and pri

  15. Electrical Components Library for HAWC2

    DEFF Research Database (Denmark)

    Cutululis, Nicolaos A.; Larsen, Torben J.; Sørensen, Poul

    and Aalborg University. In this project, the focus is on the development of a simulation platform for wind turbine systems using different simulation tools. This report presents the electric component library developed for use in the aeroelastic code HAWC2. The developed library includes both steady state...... was developed. The model includes the dynamics of the rotor fluxes. The model is suitable for a more detailed investigation of the mechanical - electrical interaction, both under normal and fault operation. For the variable speed wind turbine, a steadystate model, typically used in aeroelastic design...

  16. Preparing Canada's power systems for transition to the year 2000 : Y2K readiness assessment results for Canadian electric utility companies : first quarter 1999

    International Nuclear Information System (INIS)

    1999-01-01

    The effort made by Canadian electric utilities to minimize any power disruptions during the year 2000 (Y2K) transition is discussed and the state of readiness of the electric power industry with respect to the Y2K computer challenge is outlined. Canadian utilities started addressing Y2K issues several years ago, and today, reports show that every major electric utility in Canada is either on, or ahead of schedule to meet the industry established milestones for Y2K readiness. This report includes the assessment of all of Canada's large electric utilities, plus about 95 per cent of Canada's small distribution utilities. On average, the bulk electric utilities in Canada expect to be Y2K ready by mid-June 1999. This means that equipment and systems will operate properly for all dates including Y2K, or that there will be an operating strategy in place to mitigate the effects of any improper operations of equipment or systems. In terms of overall preparations for Y2K, Canada is ahead of the North American averages. Bulk electric utilities for non-nuclear generation are now 100 per cent complete in the inventory phase, 99 per cent complete in the assessment phase, and 91 per cent complete in the remediation/testing phase. For nuclear generation, completion rates are the same except for the remediation/testing phase which is 97 per cent complete. 1 tab., 21 figs

  17. Hybrid systems to address seasonal mismatches between electricity production and demand in nuclear renewable electrical grids

    International Nuclear Information System (INIS)

    Forsberg, Charles

    2013-01-01

    A strategy to enable zero-carbon variable electricity production with full utilization of renewable and nuclear energy sources has been developed. Wind and solar systems send electricity to the grid. Nuclear plants operate at full capacity with variable steam to turbines to match electricity demand with production (renewables and nuclear). Excess steam at times of low electricity prices and electricity demand go to hybrid fuel production and storage systems. The characteristic of these hybrid technologies is that the economic penalties for variable nuclear steam inputs are small. Three hybrid systems were identified that could be deployed at the required scale. The first option is the gigawatt-year hourly-to-seasonal heat storage system where excess steam from the nuclear plant is used to heat rock a kilometer underground to create an artificial geothermal heat source. The heat source produces electricity on demand using geothermal technology. The second option uses steam from the nuclear plant and electricity from the grid with high-temperature electrolysis (HTR) cells to produce hydrogen and oxygen. Hydrogen is primarily for industrial applications; however, the HTE can be operated in reverse using hydrogen for peak electricity production. The third option uses variable steam and electricity for shale oil production. -- Highlights: •A system is proposed to meet variable hourly to seasonal electricity demand. •Variable solar and wind electricity sent to the grid. •Base-load nuclear plants send variable steam for electricity and hybrid systems. •Hybrid energy systems can economically absorb gigawatts of variable steam. •Hybrid systems include geothermal heat storage, hydrogen, and shale-oil production

  18. Grid requirements applicable to future NPPs in the new European Electricity Framework

    International Nuclear Information System (INIS)

    Beato Castro, D.; Padill, C. M.

    2000-01-01

    With a view to keeping nuclear energy as an option for future power generation in a competitive market and taking advantage of the current operating experience, a group of European electric utilities have come together to define common requirements for the design and supply of future Light Water Reactor (LWR) plants connected to the electrical system. These requirements, defined with the aim of standardizing and adapting design to the conditions of the new electricity framework, are being included in the European Utility Requirements (EUR) document. Although there are different types of power plants operating appropriately in large electrical systems, the idea is to find the minimum requirements that will allow growth of this type of energy in the European electricity industry without reducing quality, safety and reliability of interconnected electrical systems. It is therefore necessary to take into account the features of the existing power systems and the operating characteristics and design of nuclear power plants so as to harmonize their respective technical peculiarities in the framework of the deregulated electricity sector. The definition of these grid requirements is based primarily on the operating conditions of the Union pour la Coordination de la Production et le Transport de L'Electricite (UCPTE) grid and takes into account the current Grid Code of the main European countries, for the forthcoming Issue C. This paper sets outs the most relevant aspects of the grid requirements, included in Chapter 2.3 of the EUR document Grid Requirements, Issue B, for the connection of future nuclear power plants in the European electricity system, and others that are being considered in the preparation of the new issue of the document that will take into account the deregulated electricity market situation and deal with the following aspects: General characteristics. Operation of a plant under normal grid conditions. Operation of a plant under disturbed grid

  19. Slovak Electric, Plc., 1998

    International Nuclear Information System (INIS)

    1997-06-01

    Slovenske elektrarne, a.s. (Slovak Electric, Plc., abbrevation 'SE, a.s.') is the Slovak electricity generating utility, incorporated on November 1, 1994 as one of new companies formed from substantially all of the assets and a legal successor of Slovensky energeticky podnik, s.p., founded on January 1, 1969 in the form of SEP group. From its predecessor, Slovak Electric, Plc., took over generation of power, operation of 220 kV and 400 kV power system, transit, import, export, and sale of electricity. It is also involved in generation, distribution, and sale of heat. At present, SE's share of electriciry sales in the Slovak Republic is 88.47%. Electricity is delivered to three regional distribution companies and directly to several major industrial enterprises. SE, a.s. operates one nuclear power station, three thermal power plants, and 30 hydro power plants. The second nuclear power plant is under construction (state up tu June 1997) and SE is participating in the construction of two hydro power plants and one combined cycle power plant. The efforts of SE, s.a. focus on the generation of power and heat with minimal environmental impacts. Ecology is given priority in the SE, a.s. development programmes. SE's mission is to permanently satisfy customers' needs, for an acceptable price and with minimal environmental impact. On this CD ROM next chapters are presented: (1) The structure of the Company; (2) Production units; (3) The economic power of the Company; (4) The operation culture; (5) The strategic plans of the Company

  20. What Influences Youth to Operate All-Terrain Vehicles Safely?

    Science.gov (United States)

    Grummon, A. H.; Heaney, C. A.; Dellinger, W. A.; Wilkins, J. R., III

    2014-01-01

    The operation of all-terrain vehicles (ATVs) by youth has contributed to the incidence of serious and fatal injuries among children. This study explored factors related to the frequency with which youth wore a helmet and refrained from engaging in three risky driving behaviors (driving at risky speeds, on paved roads and on unfamiliar terrain)…

  1. Environmental labelling of electricity delivery contracts in Sweden

    International Nuclear Information System (INIS)

    Kaaberger, Tomas

    2003-01-01

    Competition in the electricity market allows customers to choose between suppliers. As a consequence, customers may demand electricity from specified sources of energy. In Sweden, the Swedish Society for Nature Conservation (SSNC), operates a system of environmental labelling of electricity delivery contracts since 1996. Labelling is available for suppliers offering electricity from renewable sources of energy with some additional criteria. Companies may acquire a licence to use the label by showing ability to deliver such electricity and by agreeing to be audited. The system is private independent. It is operating on the bases of credibility earned by the SSNC during 90 years as an environmental organisation and 10 years as operator of environmental labelling of consumer products. The system is market oriented, compatible with WTO and EU market principles, and independent of governmental environmental restrictions, subsidy or quota systems. It is relying on voluntary agreements. The results are desirable if only a few by electricity under labelled contracts as well as if every customer do so. The market is growing. A majority of the suppliers have a license and may offer labelled contracts. In the year 2000, 7% of all electricity sold to final consumers was sold under labelled contracts

  2. The consumption of electricity in Deep River

    International Nuclear Information System (INIS)

    Phillips, G.J.

    1981-08-01

    This report records the development of the use of electricity in the Town of Deep River, Ontario since its incorporation in 1958. Electricity use is expressed as peak power demand, and as energy use by various classes of customers. Relevant data on population, weather and fuel prices are included. The accelerating displacment of fuel oil by electricity as an energy source for space heating is clearly demonstrated. The study was undertaken to document the effects of a large and rapidly growing seasonal load on the operation of a small electrical utility, and to provide background information for an experimental study of hybrid oil/electric space heating

  3. Gravity flow operated small electricity generator retrofit kit to flour mill industry.

    Science.gov (United States)

    Shekara, Prithivi; Kumar V, Pavan; Hosamane, Gangadharappa Gundabhakthara

    2013-10-01

    Flour milling is a grinding process to produce flour from wheat through comprehensive stages of grinding and separation. The primary energy is required to provide power used in grinding of wheat. In wheat milling, tempering is the process of adding water to wheat before milling to toughen the bran and mellow the endosperm. Gravity flow of the wheat is utilized to rotate the dampener wheel with cups to add water. Low cost gravity flow operated small electricity generator retrofit kit for dampener was designed and developed to justify low cost energy production without expensive solutions. Results of statistical analysis indicated that there was significant difference in mean values for voltage, rpm and flow rate at the 95% probability level. The resulted maximum mechanical power and measured electrical power were 5.1 W and 4.9 W respectively at wheat flow rate of 1.6 Kg/s and dampener wheel rotational velocity of 4.4 rad/s.

  4. Opportunity for inter-regional integration of electricity markets: the case of Shandong and Shanghai in East China

    International Nuclear Information System (INIS)

    Gnansounou, Edgard; Dong Jun

    2004-01-01

    In this paper, the opportunity for the inter-regional integration of the electricity market in East China is analysed on the basis of strategies for the future expansion of the electricity generation system. We assume that during its first stage, the operational breakthrough of the electricity sector reform in China will be to achieve an economic dispatch of the generating plants. On the basis of this assumed goal a multi-region model is proposed to appraise the potential benefits of an integrated inter-regional electricity market. This model includes: propositions on design and operation of the market, electricity demand forecasting, least-cost generating system expansion. As case study, three strategies of electricity supply are assessed in two provinces: Shandong and Shanghai in East China. While Shandong is a potential electricity exporter due to availability of primary energy resources, Shanghai is an electricity importer. The strategies include: autarkical expansion of each regional system, import/export only for minimizing operation costs, integration of the system expansion for minimizing total costs including operation and investment costs. One of the findings is that building up an inter-regional integrated electricity market is profitable for both the Shanghai and Shandong regions compared with the two other strategies, if the future regulation makes it possible to insure an economic dispatch of the generating power plants

  5. All-spin logic operations: Memory device and reconfigurable computing

    Science.gov (United States)

    Patra, Moumita; Maiti, Santanu K.

    2018-02-01

    Exploiting spin degree of freedom of electron a new proposal is given to characterize spin-based logical operations using a quantum interferometer that can be utilized as a programmable spin logic device (PSLD). The ON and OFF states of both inputs and outputs are described by spin state only, circumventing spin-to-charge conversion at every stage as often used in conventional devices with the inclusion of extra hardware that can eventually diminish the efficiency. All possible logic functions can be engineered from a single device without redesigning the circuit which certainly offers the opportunities of designing new generation spintronic devices. Moreover, we also discuss the utilization of the present model as a memory device and suitable computing operations with proposed experimental setups.

  6. Monitoring and analyzing features of electrical power quality system performance

    OpenAIRE

    Genci Sharko; Nike Shanku

    2010-01-01

    Power quality is a set of boundaries that allows electrical systems to function in their intended manner without significant loss of performance or life. The term is used to describe electric power that drives an electrical load and the load's ability to function properly with that electric power. Without the proper quality of the power, an electrical device may malfunction, fail prematurely or not operate at all. There are many reasons why the electric power can be of poor quality and many m...

  7. Coordinated operation of a neighborhood of smart households comprising electric vehicles, energy storage and distributed generation

    NARCIS (Netherlands)

    Paterakis, N.G.; Erdinc, O.; Pappi, I.N.; Bakirtzis, A.G.; Catalao, J.P.S.

    2016-01-01

    In this paper, the optimal operation of a neighborhood of smart households in terms of minimizing the total energy procurement cost is analyzed. Each household may comprise several assets such as electric vehicles, controllable appliances, energy storage and distributed generation. Bi-directional

  8. Steps toward an all-electric spin valve using side-gated quantum point contacts with lateral spin-orbit coupling

    Science.gov (United States)

    Bhandari, Nikhil; Dutta, Maitreya; Charles, James; Newrock, Richard S.; Cahay, Marc; Herbert, Stephen T.

    2013-03-01

    Spin-based electronics or ‘spintronics’ has been a topic of interest for over two decades. Electronic devices based on the manipulation of the electron spin are believed to offer the possibility of very small, non-volatile and ultrafast devices with very low power consumption. Since the proposal of a spin-field-effect transistor (SpinFET) by Datta and Das in 1990, many attempts have been made to achieve spin injection, detection and manipulation in semiconductor materials either by incorporating ferromagnetic materials into device architectures or by using external magnetic fields. This approach has significant design complexities, partly due to the influence of stray magnetic fields on device operation. In addition, magnetic electrodes can have magneto-resistance and spurious Hall voltages that can complicate device performance. To date, there has been no successful report of a working Datta-Das SpinFET. Over the last few years we have investigated an all-electric means of manipulating spins, one that only relies on electric fields and voltages and not on ferromagnetic materials or external magnetic fields. We believe we have found a pathway toward this goal, using in-plane side-gated quantum point contacts (QPCs) that rely on lateral spin-orbit coupling to create spin polarization. In this paper we discuss several aspects of our work, beginning with our finding what we believe is nearly complete spin-polarization in InAs QPCs by purely electrical means, our theoretical work to understand the basic mechanisms leading to that situation (asymmetric lateral confinement, lateral spin-orbit coupling and a strong e-e interaction), and our recent work extending the effort to GaAs and to dual QPC systems where one QPC acts as a polarizer and the other as an analyzer. Keynote talk at the 6th International Workshop on Advanced Materials Science and Nanotechnology, 30 October-2 November 2012, Ha Long, Vietnam.

  9. Steps toward an all-electric spin valve using side-gated quantum point contacts with lateral spin–orbit coupling

    International Nuclear Information System (INIS)

    Bhandari, Nikhil; Dutta, Maitreya; Charles, James; Cahay, Marc; Newrock, Richard S; Herbert, Stephen T

    2013-01-01

    Spin-based electronics or ‘spintronics’ has been a topic of interest for over two decades. Electronic devices based on the manipulation of the electron spin are believed to offer the possibility of very small, non-volatile and ultrafast devices with very low power consumption. Since the proposal of a spin-field-effect transistor (SpinFET) by Datta and Das in 1990, many attempts have been made to achieve spin injection, detection and manipulation in semiconductor materials either by incorporating ferromagnetic materials into device architectures or by using external magnetic fields. This approach has significant design complexities, partly due to the influence of stray magnetic fields on device operation. In addition, magnetic electrodes can have magneto-resistance and spurious Hall voltages that can complicate device performance. To date, there has been no successful report of a working Datta–Das SpinFET. Over the last few years we have investigated an all-electric means of manipulating spins, one that only relies on electric fields and voltages and not on ferromagnetic materials or external magnetic fields. We believe we have found a pathway toward this goal, using in-plane side-gated quantum point contacts (QPCs) that rely on lateral spin–orbit coupling to create spin polarization. In this paper we discuss several aspects of our work, beginning with our finding what we believe is nearly complete spin-polarization in InAs QPCs by purely electrical means, our theoretical work to understand the basic mechanisms leading to that situation (asymmetric lateral confinement, lateral spin–orbit coupling and a strong e–e interaction), and our recent work extending the effort to GaAs and to dual QPC systems where one QPC acts as a polarizer and the other as an analyzer. (review)

  10. Including all voices in international data-sharing governance.

    Science.gov (United States)

    Kaye, Jane; Terry, Sharon F; Juengst, Eric; Coy, Sarah; Harris, Jennifer R; Chalmers, Don; Dove, Edward S; Budin-Ljøsne, Isabelle; Adebamowo, Clement; Ogbe, Emilomo; Bezuidenhout, Louise; Morrison, Michael; Minion, Joel T; Murtagh, Madeleine J; Minari, Jusaku; Teare, Harriet; Isasi, Rosario; Kato, Kazuto; Rial-Sebbag, Emmanuelle; Marshall, Patricia; Koenig, Barbara; Cambon-Thomsen, Anne

    2018-03-07

    Governments, funding bodies, institutions, and publishers have developed a number of strategies to encourage researchers to facilitate access to datasets. The rationale behind this approach is that this will bring a number of benefits and enable advances in healthcare and medicine by allowing the maximum returns from the investment in research, as well as reducing waste and promoting transparency. As this approach gains momentum, these data-sharing practices have implications for many kinds of research as they become standard practice across the world. The governance frameworks that have been developed to support biomedical research are not well equipped to deal with the complexities of international data sharing. This system is nationally based and is dependent upon expert committees for oversight and compliance, which has often led to piece-meal decision-making. This system tends to perpetuate inequalities by obscuring the contributions and the important role of different data providers along the data stream, whether they be low- or middle-income country researchers, patients, research participants, groups, or communities. As research and data-sharing activities are largely publicly funded, there is a strong moral argument for including the people who provide the data in decision-making and to develop governance systems for their continued participation. We recommend that governance of science becomes more transparent, representative, and responsive to the voices of many constituencies by conducting public consultations about data-sharing addressing issues of access and use; including all data providers in decision-making about the use and sharing of data along the whole of the data stream; and using digital technologies to encourage accessibility, transparency, and accountability. We anticipate that this approach could enhance the legitimacy of the research process, generate insights that may otherwise be overlooked or ignored, and help to bring valuable

  11. Geothermal electricity generation and desalination: an integrated process design to conserve latent heat with operational improvements

    KAUST Repository

    Missimer, Thomas M.; Ng, Kim Choon; Thuw, Kyaw; Wakil Shahzad, Muhammad

    2016-01-01

    A new process combination is proposed to link geothermal electricity generation with desalination. The concept involves maximizing the utilization of harvested latent heat by passing the turbine exhaust steam into a multiple effect distillation system and then into an adsorption desalination system. Processes are fully integrated to produce electricity, desalted water for consumer consumption, and make-up water for the geothermal extraction system. Further improvements in operational efficiency are achieved by adding a seawater reverse osmosis system to the site to utilize some of the generated electricity and using on-site aquifer storage and recovery to maximize water production with tailoring of seasonal capacity requirements and to meet facility maintenance requirements. The concept proposed conserves geothermally harvested latent heat and maximizes the economics of geothermal energy development. Development of a fully renewable energy electric generation-desalination-aquifer storage campus is introduced within the framework of geothermal energy development. © 2016 The Author(s). Published by Taylor & Francis

  12. Geothermal electricity generation and desalination: an integrated process design to conserve latent heat with operational improvements

    KAUST Repository

    Missimer, Thomas M.

    2016-02-05

    A new process combination is proposed to link geothermal electricity generation with desalination. The concept involves maximizing the utilization of harvested latent heat by passing the turbine exhaust steam into a multiple effect distillation system and then into an adsorption desalination system. Processes are fully integrated to produce electricity, desalted water for consumer consumption, and make-up water for the geothermal extraction system. Further improvements in operational efficiency are achieved by adding a seawater reverse osmosis system to the site to utilize some of the generated electricity and using on-site aquifer storage and recovery to maximize water production with tailoring of seasonal capacity requirements and to meet facility maintenance requirements. The concept proposed conserves geothermally harvested latent heat and maximizes the economics of geothermal energy development. Development of a fully renewable energy electric generation-desalination-aquifer storage campus is introduced within the framework of geothermal energy development. © 2016 The Author(s). Published by Taylor & Francis

  13. Vehicle electrical system state controller

    Science.gov (United States)

    Bissontz, Jay E.

    2017-10-17

    A motor vehicle electrical power distribution system includes a plurality of distribution sub-systems, an electrical power storage sub-system and a plurality of switching devices for selective connection of elements of and loads on the power distribution system to the electrical power storage sub-system. A state transition initiator provides inputs to control system operation of switching devices to change the states of the power distribution system. The state transition initiator has a plurality of positions selection of which can initiate a state transition. The state transition initiator can emulate a four position rotary ignition switch. Fail safe power cutoff switches provide high voltage switching device protection.

  14. Control and Operation of Islanded Distribution System

    DEFF Research Database (Denmark)

    Mahat, Pukar

    deviation and real power shift. When a distribution system, with all its generators operating at maximum power, is islanded, the frequency will go down if the total load is more than the total generation. An under-frequency load shedding procedure for islanded distribution systems with DG unit(s) based...... states. Short circuit power also changes when some of the generators in the distribution system are disconnected. This may result in elongation of fault clearing time and hence disconnection of equipments (including generators) in the distribution system or unnecessary operation of protective devices...... operational challenges. But, on the other hand, it has also opened up some opportunities. One opportunity/challenge is an islanded operation of a distribution system with DG unit(s). Islanding is a situation in which a distribution system becomes electrically isolated from the remainder of the power system...

  15. Financial statistics of major US publicly owned electric utilities 1992

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-01

    The 1992 edition of the Financial Statistics of Major US Publicly Owned Electric Utilities publication presents 4 years (1989 through 1992) of summary financial data and current year detailed financial data on the major publicly owned electric utilities. The objective of the publication is to provide Federal and State governments, industry, and the general public with current and historical data that can be used for policymaking and decisionmaking purposes related to publicly owned electric utility issues. Generator and nongenerator summaries are presented in this publication. Four years of summary financial data are provided. Summaries of generators for fiscal years ending June 30 and December 31, nongenerators for fiscal years ending June 30 and December 31, and summaries of all respondents are provided. The composite tables present aggregates of income statement and balance sheet data, as well as financial indicators. Composite tables also display electric operation and maintenance expenses, electric utility plant, number of consumers, sales of electricity, and operating revenue, and electric energy account data. The primary source of publicly owned financial data is the Form EIA-412, {open_quotes}Annual Report of Public Electric Utilities.{close_quotes} Public electric utilities file this survey on a fiscal year, rather than a calendar year basis, in conformance with their recordkeeping practices. In previous editions of this publication, data were aggregated by the two most commonly reported fiscal years, June 30 and December 31. This omitted approximately 20 percent of the respondents who operate on fiscal years ending in other months. Accordingly, the EIA undertook a review of the Form EIA-412 submissions to determine if alternative classifications of publicly owned electric utilities would permit the inclusion of all respondents.

  16. Optimal Operation of Plug-In Electric Vehicles in Power Systems with High Wind Power Penetrations

    DEFF Research Database (Denmark)

    Hu, Weihao; Su, Chi; Chen, Zhe

    2013-01-01

    in the power systems with high wind power penetrations. In this paper, the integration of plug-in electric vehicles in the power systems with high wind power penetrations is proposed and discussed. Optimal operation strategies of PEV in the spot market are proposed in order to decrease the energy cost for PEV......The Danish power system has a large penetration of wind power. The wind fluctuation causes a high variation in the power generation, which must be balanced by other sources. The battery storage based Plug-In Electric Vehicles (PEV) may be a possible solution to balance the wind power variations...... owners. Furthermore, the application of battery storage based aggregated PEV is analyzed as a regulation services provider in the power system with high wind power penetrations. The western Danish power system where the total share of annual wind power production is more than 27% of the electrical energy...

  17. Electric battery with gas-operated electrolyte flow. Elektrischer Akkumulator mit gasbetaetigter Elektrolytbewegung

    Energy Technology Data Exchange (ETDEWEB)

    Guetlich, K.F.; Kappus, W.; Zweigardt, H.; Eckardt, R.

    1986-08-28

    The invention relates to an electric accumulator with gas-operated electrolyte flow between electrode plates connected to form a plate block according to the principle of the mammoth pump. At least two supply pipes arranged parallel to each other and with connected gas supply are mounted to a base plate of non-conducting material. The base plate can be pushed in between plate block and housing wall. The base plate consists of two plastic foils of equal height and width the supply pipes and gas leads being formed by protrusions in the plastic foil.

  18. Electric battery with gas-operated electrolyte flow. Elektrischer Akkumulator mit gasbetaetigter Elektrolytbewegung

    Energy Technology Data Exchange (ETDEWEB)

    Guetlich, K.F.; Kappus, W.; Zweigardt, H.; Eckardt, R.

    1980-10-09

    The invention relates to an electric accumulator with gas-operated electrolyte flow between electrode plates connected to form a plate block according to the principle of the mammoth pump. At least two supply pipes arranged parallel to each other and with connected gas supply are mounted to a base plate of non-conducting material. The base plate can be pushed in between plate block and housing wall. The base plate consists of two plastic foils of equal height and width the supply pipes and gas leads being formed by protrusions in the plastic foil.

  19. Radial electric field evolution in various operational modes in the TUMAN-3M tokamak

    International Nuclear Information System (INIS)

    Askinazi, L G; Kornev, V A; Krikunov, S V; Lebedev, S V; Smirnov, A I; Tukachinsky, A S; Vildjunas, M I; Zhubr, N A; Krupnik, L I; Tendler, M

    2008-01-01

    Radial electric field evolution has been studied on the TUAMN-3M tokamak in different modes of operation: ohmic and NBI heating, L- and H-modes, with and without strong MHD activity. Peripheral radial electric field was measured using Langmuire probes, which were inserted up to 2cm inside LCFS, while core plasma potential evolution was measured using HIBP diagnostic. It was found, that in presence of strong MHD activity radial electric field in a vicinity of the island changed sign from negative to positive and could reach up to 4kV/m. Central plasma potential exhibited a positive perturbation of ∼700V during the MHD burst. This positive radial electric field might lead to H-mode termination, both in ohmic and NBI heating cases. Possible mechanism of the positive E r generation, namely the electron losses along ergodized magnetic field lines in the presence of MHD-island, is discussed. The same mechanism might be responsible for the positive potential spikes during a saw-tooth crash, also observed using HIBP. Another phenomenon observed using HIBP was quasi-coherent potential oscillations with the frequency close to one of the GAM. Possible location of these oscillations in the core region r/a ∼ 0.33 is discussed

  20. 76 FR 17447 - Penske Logistics LLC a Subsidiary of General Electric/Penske Corporation Including On-Site Leased...

    Science.gov (United States)

    2011-03-29

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,897] Penske Logistics LLC a Subsidiary of General Electric/Penske Corporation Including On-Site Leased Workers From Kelly Temporary... (TAA) applicable to workers and former workers of Penske Logistics LLC, a subsidiary of General...

  1. Light, rest mass and electric charge quanta all formed by neutrinos?

    Science.gov (United States)

    Chen, Shao-Guang

    In high energy physics experiments the electric charge and rest mass of particles can commonly transform into the photons, vice versa. Its reason QFT can only give a vague answer: based on the particle creation and annihilation operators. There are not more clear answers or conjecture? At least, light, electric charge and rest mass should have a collective structure component, if not, the transformation is unable understanding. An elementary answer is that neutrino and antineutrino as their collective structure component. In the paper ‘Chen Qiliang & Wang Bin, The formation and characteristics of Chen Shaoguang's formula, China Science &Technology Overview 127101-103 (2011)’, the lowest energy state vertical polarized left spin 1/2 neutrino and right spin 1/2 antineutrino are just the left, right advance unit quanta la _{0}nuυ, ra nuυ _{0} and left, right back unit quanta lb (0) nuυ, rb nuυ (0) , it again compose into spin 1 unit photon la-ra _{0}nuυnuυ _{0} and back-photon lb-rb (0) nuυnuυ (0) , spin 0 unit rest mass ra-rb nuυ _{0}nuυ (0) and anti-mass la-lb _{0}nuυ (0) nuυ, spin 0 unit positive charge la-rb _{0}nuυnuυ (0) and negative charge ra-lb nuυ _{0} (0) nuυ. The physical vacuum is the even collocation of non-combinational nuυ _{0} or _{0}nuυ. It accord to the high energy physics experimental results of the transformation among the photons, masses quanta and charges quanta. In my paper ‘Quanta turn-advance ism, China Science && Technology Overview 131 192-210 (2011)’, QFT four-dimensional uncertainty principle and momentum-energy conservation law had been generalized as a five-dimensional equations: de Broglie wavelength as a position vector \\underline{q}= (i c t, r, s), momentum \\underline{P} = (i E / c, P, U c), \\underline{q} = i h / \\underline{P}, \\underline{q} \\underline{q} = 0, \\underline{P} \\underline{P} = 0, Sigma∑ \\underline{P} = \\underline{P} (0) . The five-dimensional time-space-spin had been quantized as a

  2. Electricity: an indigenous transport fuel

    Energy Technology Data Exchange (ETDEWEB)

    Byers, D J

    1978-12-25

    Potential reserves of hydro and geothermal power are adequate to power all road-transport vehicles should these be converted to electric drives in the future. Conversion of petrol vehicles to electric drives results in a significant increase in energy-utilization efficiency coupled with a decrease in costs, both to the country in overseas funds and to the driver in operating costs. As yet, however, New Zealand has no plan to use these resources in a transport role and is supporting no feasibility research.

  3. Survey of seismic conditions of drilling and blasting operations near overhead electricity power lines

    Science.gov (United States)

    Korshunov, G. I.; Afanasev, P. I.; Bulbasheva, I. A.

    2017-10-01

    The monitoring and survey results of drilling and blasting operations are specified during the development of Afanasyevsky deposit of cement raw materials for a 110 kV electricity power lines structure. Seismic explosion waves and air shock waves were registered in the course of monitoring. The dependency of peak particle velocities on the scaled distance and explosive weight by the delay time was obtained.

  4. Electrical Safety for Non-Electricians

    Science.gov (United States)

    ... handled cement finishing floats • Metal ladders • Raised dump truck beds • Scaffolding But electrical hazards are also at ... must be grounded. Your employer must check all electric systems, including wiring and switches, to be sure ...

  5. Hybrid multidimensional design for heterogeneous data supported by ontological analysis: an application case in the Brazilian electric system operation

    NARCIS (Netherlands)

    Moreira, João; Cordeiro, Kelli; Campos, Maria Luiza M.; Borges, Marcos

    2015-01-01

    An issue in operating a national electric system is how the corporate image of an Independent System Operator (ISO) can be impacted by disturbances in the system and their related news publications from specialized press. To deal with it, a solution was developed in the context of the Brazilian

  6. Price-based optimal control of electrical power systems

    OpenAIRE

    Jokic, A.

    2007-01-01

    During the past decade, electrical power systems have been going through some major restructuring processes. From monopolistic, highly regulated and one utility controlled operation, a system is being restructured to include many parties competing for energy production and consumption, and for provision of many of the ancillary services necessary for system operation. With the emergence of competitive markets as central operational mechanisms, the prime operational objective has shifted from ...

  7. Simulation of a heavy-duty diesel engine with electrical turbocompounding system using operating charts for turbocharger components and power turbine

    International Nuclear Information System (INIS)

    Katsanos, C.O.; Hountalas, D.T.; Zannis, T.C.

    2013-01-01

    Highlights: • A diesel model was developed using charts for turbocharger and power turbine. • The maximum value of bsfc improvement is 4.1% at 100% engine load. • The generated electric power ranges from 23 kW to 62 kW. • Turbocharger turbine efficiency decreases slightly with the power turbine speed. • Turbocompounding increases the average pressure value in the exhaust manifold. - Abstract: In diesel engines, approximately 30–40% of the energy supplied by the fuel is rejected to the ambience through exhaust gases. Therefore, there is a potentiality for further considerable increase of diesel engine efficiency with the utilization of exhaust gas heat and its conversion to mechanical or electrical energy. In the present study, the operational behavior of a heavy-duty (HD) diesel truck engine equipped with an electric turbocompounding system is examined on a theoretical basis. The electrical turbocompounding configuration comprised of a power turbine coupled to an electric generator, which is installed downstream to the turbocharger (T/C) turbine. A diesel engine simulation model has been developed using operating charts for both turbocharger and power turbine. A method for introducing the operating charts into the engine model is described thoroughly. A parametric analysis is conducted with the developed simulation tool, where the varying parameter is the rotational speed of power turbine shaft. In this study, the interaction between the power turbine and the turbocharged diesel engine is examined in detail. The effect of power turbine speed on T/C components efficiencies, power turbine efficiency, exhaust pressure and temperature, engine boost pressure and air to fuel ratio is evaluated. In addition, theoretical results for the potential impact of electrical turbocompounding on the generated electric power, net engine power and relative improvement of brake specific fuel consumption (bsfc) are provided. The critical evaluation of the theoretical

  8. 30 CFR 18.91 - Electric equipment for which field approvals will be issued.

    Science.gov (United States)

    2010-07-01

    ..., by the owner-coal mine operator of such machines including any associated electrical equipment... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric equipment for which field approvals... OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT...

  9. 75 FR 11918 - General Electric Kentucky Glass Plant, Lighting, LLC, Including On-Site Leased Workers From the...

    Science.gov (United States)

    2010-03-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-72,011] General Electric Kentucky Glass Plant, Lighting, LLC, Including On-Site Leased Workers From the Patty Tipton Company, Aetna Building Maintenance, and Concentra, Lexington, KY; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordanc...

  10. NASA Electric Propulsion System Studies

    Science.gov (United States)

    Felder, James L.

    2015-01-01

    An overview of NASA efforts in the area of hybrid electric and turboelectric propulsion in large transport. This overview includes a list of reasons why we are looking at transmitting some or all of the propulsive power for the aircraft electrically, a list of the different types of hybrid-turbo electric propulsion systems, and the results of 4 aircraft studies that examined different types of hybrid-turbo electric propulsion systems.

  11. All-electric spin modulator based on a two-dimensional topological insulator

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Xianbo; Ai, Guoping [School of Computer Science, Jiangxi University of Traditional Chinese Medicine, Nanchang 330004 (China); Liu, Ying; Yang, Shengyuan A., E-mail: shengyuan-yang@sutd.edu.sg [Research Laboratory for Quantum Materials, Singapore University of Technology and Design, Singapore 487372 (Singapore); Liu, Zhengfang [School of Science, East China Jiaotong University, Nanchang 330013 (China); Zhou, Guanghui, E-mail: ghzhou@hunnu.edu.cn [Key Laboratory for Low-Dimensional Structures and Quantum Manipulation (Ministry of Education), and Synergetic Innovation Center for Quantum Effects and Applications, Hunan Normal University, Changsha 410081 (China)

    2016-01-18

    We propose and investigate a spin modulator device consisting of two ferromagnetic leads connected by a two-dimensional topological insulator as the channel material. It exploits the unique features of the topological spin-helical edge states, such that the injected carriers with a non-collinear spin-polarization direction would travel through both edges and show interference effect. The conductance of the device can be controlled in a simple and all-electric manner by a side-gate voltage, which effectively rotates the spin-polarization of the carrier. At low voltages, the rotation angle is linear in the gate voltage, and the device can function as a good spin-polarization rotator by replacing the drain electrode with a non-magnetic material.

  12. Operational water consumption and withdrawal factors for electricity generating technologies: a review of existing literature

    International Nuclear Information System (INIS)

    Macknick, J; Newmark, R; Heath, G; Hallett, K C

    2012-01-01

    This report provides estimates of operational water withdrawal and water consumption factors for electricity generating technologies in the United States. Estimates of water factors were collected from published primary literature and were not modified except for unit conversions. The water factors presented may be useful in modeling and policy analyses where reliable power plant level data are not available. Major findings of the report include: water withdrawal and consumption factors vary greatly across and within fuel technologies, and water factors show greater agreement when organized according to cooling technologies as opposed to fuel technologies; a transition to a less carbon-intensive electricity sector could result in either an increase or a decrease in water use, depending on the choice of technologies and cooling systems employed; concentrating solar power technologies and coal facilities with carbon capture and sequestration capabilities have the highest water consumption values when using a recirculating cooling system; and non-thermal renewables, such as photovoltaics and wind, have the lowest water consumption factors. Improved power plant data and further studies into the water requirements of energy technologies in different climatic regions would facilitate greater resolution in analyses of water impacts of future energy and economic scenarios. This report provides the foundation for conducting water use impact assessments of the power sector while also identifying gaps in data that could guide future research. (letter)

  13. Comprehensive dictionary of electrical engineering

    CERN Document Server

    Laplante, Philip A

    1998-01-01

    The Comprehensive Dictionary of Electrical Engineering is a complete lexicon covering all the fields of electrical engineering.Areas examined include:applied electrical engineeringmicrowave engineeringcontrol engineeringpower engineeringdigital systems engineeringdevice electronicsand much more! The book provides workable definitions for practicing engineers, serves as a reference and research tool for students, and offers practical information for scientists and engineers in other disciplines.

  14. Hofstadter spectrum in electric and magnetic fields

    International Nuclear Information System (INIS)

    Kunold, Alejandro; Torres, Manuel

    2005-01-01

    The problem of Bloch electrons in two dimensions subjected to magnetic and intense electric fields is investigated. Magnetic translations, electric evolution, and energy translation operators are used to specify the solutions of the Schroedinger equation. For rational values of the magnetic flux quanta per unit cell and commensurate orientations of the electric field relative to the original lattice, an extended superlattice can be defined and a complete set of mutually commuting space-time symmetry operators is obtained. Dynamics of the system is governed by a finite difference equation that exactly includes the effects of: an arbitrary periodic potential, an electric field orientated in a commensurable direction of the lattice, and coupling between Landau levels. A weak periodic potential broadens each Landau level in a series of minibands, separated by the corresponding minigaps. The addition of the electric field induces a series of avoided and exact crossing of the quasienergies, for sufficiently strong electric field the spectrum evolves into equally spaced discreet levels, in this 'magnetic Stark ladder' the energy separation is an integer multiple of hE/aB, with a the lattice parameter

  15. Integrating Variable Renewable Energy in Electric Power Markets. Best Practices from International Experience

    Energy Technology Data Exchange (ETDEWEB)

    Cochran, Jaquelin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bird, Lori [National Renewable Energy Lab. (NREL), Golden, CO (United States); Heeter, Jenny [National Renewable Energy Lab. (NREL), Golden, CO (United States); Arent, Douglas J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-04-30

    Many countries—reflecting very different geographies, markets, and power systems—are successfully managing high levels of variable renewable energy on the electric grid, including that from wind and solar energy. This document summarizes policy best practices that energy ministers and other stakeholders can pursue to ensure that electricity markets and power systems can effectively coevolve with increasing penetrations of variable renewable energy. There is no one-size-fits-all approach; each country studied has crafted its own combination of policies, market designs, and system operations to achieve the system reliability and flexibility needed to successfully integrate renewables. Notwithstanding this diversity, the approaches taken by the countries studied all coalesce around five strategic areas: lead public engagement, particularly for new transmission; coordinate and integrate planning; develop rules for market evolution that enable system flexibility; expand access to diverse resources and geographic footprint of operations; and improve system operations. This study also emphatically underscores the value of countries sharing their experiences. The more diverse and robust the experience base from which a country can draw, the more likely that it will be able to implement an appropriate, optimized, and system-wide approach.

  16. Large contribution to the neutron electric dipole moment from a dimension six four quark operator

    International Nuclear Information System (INIS)

    He, Xiaogang; McKellar, B.

    1992-01-01

    In this paper the contribution of a dimension six four quark operator (Q q ) to the neutron electric dipole moment was studied. It was found that this contribution dominates over other contributions by at least one order of magnitude in Left-Right symmetric models and two orders of magnitude in di-quark scalar models. 10 refs., 1 fig

  17. The changing Swiss electricity - Critical views

    International Nuclear Information System (INIS)

    Wilms, E.F.J.

    2001-01-01

    This book takes a critical look at developments in the Swiss electricity market and, in particular, criticises national, regional and local energy policy, which the author considers to be incoherent. The book first describes how the electricity market works, the main players involved and the daily problems that have to be solved. Then, the problems that could be caused by liberalisation, including the question of transit fees, the development of electricity prices for consumers, changes in the structure of the electricity business and third party access are discussed. The second part of the book examines legal aspects of proposed electricity market legislation and then presents 16 propositions covering energy policy, market regulation, unbundling not only of electricity generation, distribution and services but also of politics and business, the revision of proposed liberalisation legislation, taxation aspects as well as the national and international operation of the electricity grid. The book further examines three regional electricity utilities and the attempts to privatise them, which did not meet with the approval of the voting public, and discusses the suspicion cast on certain politicians, that they try to push through the particular interests of groups they are closely associated with. The book is also includes a bibliography and a list of useful addresses

  18. Electrical machines & drives

    CERN Document Server

    Hammond, P

    1985-01-01

    Containing approximately 200 problems (100 worked), the text covers a wide range of topics concerning electrical machines, placing particular emphasis upon electrical-machine drive applications. The theory is concisely reviewed and focuses on features common to all machine types. The problems are arranged in order of increasing levels of complexity and discussions of the solutions are included where appropriate to illustrate the engineering implications. This second edition includes an important new chapter on mathematical and computer simulation of machine systems and revised discussions o

  19. Plans for Assessing Contractor Performance for the Camp Lemonnier Base Operations Support Contract Needed Improvement

    Science.gov (United States)

    2015-08-27

    electrical power such that all electrical requirements are continually met. 18. Wastewater : Operate and maintain the wastewater treatment plant and...supply—in our review. Roles and Responsibilities NAVFAC provides public works support for U.S. Naval shore installations around the world , and, as...Electrical: Operate and maintain the electrical power generation plant and distribution system to safely produce, transmit, and distribute reliable

  20. Optimal Planning and Operation Management of a Ship Electrical Power System with Energy Storage System

    DEFF Research Database (Denmark)

    Anvari-Moghaddam, Amjad; Dragicevic, Tomislav; Meng, Lexuan

    2016-01-01

    Next generation power management at all scales is highly relying on the efficient scheduling and operation of different energy sources to maximize efficiency and utility. The ability to schedule and modulate the energy storage options within energy systems can also lead to more efficient use...... of the generating units. This optimal planning and operation management strategy becomes increasingly important for off-grid systems that operate independently of the main utility, such as microgrids or power systems on marine vessels. This work extends the principles of optimal planning and economic dispatch...... for the proposed plan is derived based on the solution from a mixed-integer nonlinear programming (MINLP) problem. Simulation results showed that including well-sized energy storage options together with optimal operation management of generating units can improve the economic operation of the test system while...

  1. Wound management and outcome of 595 electrical burns in a major burn center.

    Science.gov (United States)

    Li, Haisheng; Tan, Jianglin; Zhou, Junyi; Yuan, Zhiqiang; Zhang, Jiaping; Peng, Yizhi; Wu, Jun; Luo, Gaoxing

    2017-06-15

    Electrical burns are important causes of trauma worldwide. This study aims to analyze the clinical characteristics, wound management, and outcome of electric burns. This retrospective study was performed at the Institute of Burn Research of the Third Military Medical University during 2013-2015. Data including the demographics, injury patterns, wound treatment, and outcomes were collected and analyzed. A total of 595 electrical burn patients (93.8% males) were included. The average age was 37.3 ± 14.6 y, and most patients (73.5%) were aged 19∼50 years. Most patients (67.2%) were injured in work-related circumstances. The mean total body surface area was 8.8 ± 11.8% and most wounds (63.5%) were full-thickness burns. Operation times of high-voltage burns and current burns were higher than those of low-voltage burns and arc burns, respectively. Of the 375 operated patients, 83.2% (n = 312) underwent skin autografting and 49.3% (n = 185) required skin flap coverage. Common types of skin flaps were adjacent (50.3%), random (42.2%), and pedicle (35.7%). Amputation was performed in 107 cases (18.0%) and concentrated on the hands (43.9%) and upper limbs (39.3%). The mean length of stay was 42.9 ± 46.3 d and only one death occurred (0.2%). Current burns and higher numbers of operations were major risk factors for amputation and length of stay, respectively. Electrical burns mainly affected adult males with occupational exposures in China. Skin autografts and various skin flaps were commonly used for electric burn wound management. More standardized and effective strategies of treatment and prevention are still needed to decrease amputation rates. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Interim staff position on environmental qualification of safety-related electrical equipment: including staff responses to public comments. Regulatory report

    International Nuclear Information System (INIS)

    Szukiewicz, A.J.

    1981-07-01

    This document provides the NRC staff positions regarding selected areas of environmental qualification of safety-related electrical equipment, in the resolution of Unresolved Safety Issue A-24, 'Qualification of Class IE Safety-Related Equipment.' The positions herein are applicable to plants that are or will be in the construction permit (CP) or operating license (OL) review process and that are required to satisfy the requirements set forth in either the 1971 or the 1974 version of IEEE-323 standard

  3. Nuclear Power as an Option in Electrical Generation Planning for Small Economy and Electricity Grid

    International Nuclear Information System (INIS)

    Tomsic, Z.

    2012-01-01

    Implementing a NPP in countries with relatively small total GDP (small economy) and usually with small electricity grid face two major problems and constrains: the ability to obtain the considerable financial resources required on reasonable terms and to connect large NPP to small electricity grid. Nuclear generation financing in developing countries involves complex issues that need to be fully understood and dealt with by all the parties involved. The main topics covered by paper will be the: special circumstances related to the financing of NPP, costs and economic feasibility of NPP, conventional approaches for financing power generation projects in developing countries, alternative approaches for mobilizing financial resources. The safe and economic operation of a nuclear power plant (NPP) requires the plant to be connected to an electrical grid system that has adequate capacity for exporting the power from the NPP, and for providing a reliable electrical supply to the NPP for safe start-up, operation and normal or emergency shut-down of the plant. Connection of any large new power plant to the electrical grid system in a country may require significant modification and strengthening of the grid system, but for NPPs there may be added requirements to the structure of the grid system and the way it is controlled and maintained to ensure adequate reliability. Paper shows the comparative assesment of differrent base load technologies as an option in electrical generation planning for small economy and electricity grid.(author).

  4. Electric Motor-Generator for a Hybrid Electric Vehicle

    OpenAIRE

    Odvářka, Erik; Mebarki, Abdeslam; Gerada, David; Brown, Neil; Ondrůšek, Čestmír

    2009-01-01

    Several topologies of electrical machines can be used to meet requirements for application in a hybrid electric vehicle. This paper describes process of an electric motor-generator selection, considering electromagnetic, thermal and basic control design. The requested electrical machine must develop 45 kW in continuous operation at 1300 rpm with field weakening capability up to 2500 rpm. Both radial and axial flux topologies are considered as potential candidates. A family of axial flux machi...

  5. 46 CFR 76.25-35 - Operation and installation.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Operation and installation. 76.25-35 Section 76.25-35... EQUIPMENT Automatic Sprinkling System, Details § 76.25-35 Operation and installation. (a) The system shall... all its components shall be used for no other purpose. (h) All wiring and electrical circuits and...

  6. Electricity pricing and load dispatching in deregulated electricity market

    International Nuclear Information System (INIS)

    Geerli; Niioka, S.; Yokoyama, R.

    2003-01-01

    A rapid move to a market-based electric power industry will significantly alter the structure of electricity pricing and system operation. In this paper, we consider a game of negotiation in the electricity market, involving electric utilities, independent power producers (IPPs) and large-scale customers. We analyze the two-level game strategies for the negotiation process between utilities, IPPs and customers. These have been previously recognized as a way to come up with a rational decision for competitive markets, in which players intend to maximize their own profits. The derived operation rules based on competition can be viewed as an extension of the conventional equal incremental cost method for the deregulated power system. The proposed approach was applied to several systems to verify its effectiveness. (Author)

  7. The electricity market 2003

    International Nuclear Information System (INIS)

    2003-01-01

    The electricity markets in the Nordic countries have undergone major changes since the electricity market reform work was started in the early 1990s. We now have a common Nordic electricity market that includes all of the Nordic countries, with the exception of Iceland. The objective of the electricity market reform is to introduce increased competition, to give consumers greater freedom of choice and also, by open and increased trade in electricity, create the conditions for efficient pricing. The Swedish Energy Agency is the supervisory authority specified in the Electricity Act, and one of the tasks entrusted to it by the Government is to follow developments on the electricity market and regularly compile and report current market information. The purpose of 'The Electricity Market 2003' publication is to meet the need for generalized and easily accessible information on the conditions on the Nordic market. The publication also includes summaries of the information from recent years concerning power generation and utilization in the Nordic countries, the structure of the electricity market from the players' perspective, trade in electricity in the Nordic countries and in northern Europe, electricity prices in the Nordic and other countries, and the impact of the electricity sector on the environment

  8. Electrically protected resonant exchange qubits in triple quantum dots.

    Science.gov (United States)

    Taylor, J M; Srinivasa, V; Medford, J

    2013-08-02

    We present a modulated microwave approach for quantum computing with qubits comprising three spins in a triple quantum dot. This approach includes single- and two-qubit gates that are protected against low-frequency electrical noise, due to an operating point with a narrowband response to high frequency electric fields. Furthermore, existing double quantum dot advances, including robust preparation and measurement via spin-to-charge conversion, are immediately applicable to the new qubit. Finally, the electric dipole terms implicit in the high frequency coupling enable strong coupling with superconducting microwave resonators, leading to more robust two-qubit gates.

  9. Model documentation: Electricity market module, electricity finance and pricing submodule

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-07

    The purpose of this report is to define the objectives of the model, describe its basic approach, and provide detail on how it works. The EFP is a regulatory accounting model that projects electricity prices. The model first solves for revenue requirements by building up a rate base, calculating a return on rate base, and adding the allowed expenses. Average revenues (prices) are calculated based on assumptions regarding regulator lag and customer cost allocation methods. The model then solves for the internal cash flow and analyzes the need for external financing to meet necessary capital expenditures. Finally, the EFP builds up the financial statements. The EFP is used in conjunction with the National Energy Modeling System (NEMS). Inputs to the EFP include the forecast generating capacity expansion plans, operating costs, regulator environment, and financial data. The outputs include forecasts of income statements, balance sheets, revenue requirements, and electricity prices.

  10. Electric Vehicles for Improved Operation of Power Systems with High Wind Power Penetration

    OpenAIRE

    Larsen, Esben; Chandrashekhara, Divya K; Østergaard, Jacob

    2008-01-01

    In a power system with a high share of wind energy the wind fluctuation causes a variation in the power generation, which must be compensated from other sources. The situation in Denmark with a penetration of more than 20% wind in yearly average is presented. The introduction of electric drive vehicles (EDV) as flexible loads can improve the system operation. Bidirectional power exchange through batteries (vehicle to grid) can be seen as a storage system in the grid. An analysis of possible e...

  11. Costs and Operating Dynamics of Integrating Distributed Energy Resources in Commercial and Industrial Buildings with Electric Vehicle Charging

    Science.gov (United States)

    Flores, Robert Joseph

    Growing concerns over greenhouse gas and pollutant emissions have increased the pressure to shift energy conversion paradigms from current forms to more sustainable methods, such as through the use of distributed energy resources (DER) at industrial and commercial buildings. This dissertation is concerned with the optimal design and dispatch of a DER system installed at an industrial or commercial building. An optimization model that accurately captures typical utility costs and the physical constraints of a combined cooling, heating, and power (CCHP) system is designed to size and operate a DER system at a building. The optimization model is then used with cooperative game theory to evaluate the financial performance of a CCHP investment. The CCHP model is then modified to include energy storage, solar powered generators, alternative fuel sources, carbon emission limits, and building interactions with public and fleet PEVs. Then, a separate plugin electric vehicle (PEV) refueling model is developed to determine the cost to operate a public Level 3 fast charging station. The CCHP design and dispatch results show the size of the building load and consistency of the thermal loads are critical to positive financial performance. While using the CCHP system to produce cooling can provide savings, heat production drives positive financial performance. When designing the DER system to reduce carbon emissions, the use of renewable fuels can allow for a gas turbine system with heat recovery to reduce carbon emissions for a large university by 67%. Further reductions require large photovoltaic installations coupled with energy storage or the ability to export electricity back to the grid if costs are to remain relatively low. When considering Level 3 fast charging equipment, demand charges at low PEV travel levels are sufficiently high to discourage adoption. Integration of the equipment can reduce demand charge costs only if the building maximum demand does not coincide

  12. Electricity supply in Sweden 1983

    International Nuclear Information System (INIS)

    1984-01-01

    The year 1983 was characterized by a continued decrease in oil consumption and an increase in electricity consumption. Totally the supply of fuels decreased from 278TWh to 264 TWh in 1983. The electricity supply increased from 99.9 TWh in 1982 to 110.8 TWh in 1983. The consumers total energy use decreased from 358 TWh in 1982 to 355 TWh in 1983. Electricity consumption excluding transmission losses increased from 91,4 TWh in 1982 to 101.1TWh in 1983. The increase was due to electric space heating disconnectable electric boilers and to industry. At the end of 1983 the electric heating subscriptions are estimated to corresponds to 45 percent of all one-family houses. Hydropower accounted for 54 percent and nucler power accounted for 34 percent of the total supply of electricity in 1983. The highest hourly load during 1983 amounted to 20862 MW. The lowest load during 1983 amounted to 5185 MW. Ten nuclear power units were in commercial operation during the year. The energy availability figures were as follows: Barsebaeck 1 85 percent, Barsebaeck 2 82 percent, Forsmark 1 84 percent, Forsmark 2 88 percent, Oskarshamn 1 87 percent, Oskarshamn 2 83 percent, Ringhals 1 59 percent and Ringhals 2 68 percent. The production of electricity from conventional thermal power stations was only 4.0 TWh. Back pressure power in industry contributed 2.5 TWh of this figure and combined power and district heating stations 1.3 TWh. Two coal fired combined power and district heating plants were added and sevearl combined power and district heating plants have been rebuilt to be coal fired. The high voltage power grid system permits joint operation by all the power companies in the country, and the major power companies utilize the network for exchanging surplus power with other power companies. An account of the public debate on energy in Sweden during 1983 is also given.(L.E.)

  13. Electric vehicles’ influence on Smart Grids

    Directory of Open Access Journals (Sweden)

    Marta R. Jabłońska

    2012-06-01

    Full Text Available Aim of the paper is to demonstrate evolution of Electric Vehicles (EV and their infl uence on the Smart Grid (SG. Starting from USA defi nition of the SG considering the fi fth- and sixth- properties of the SG: It accommodates all generation and storage options and it enables new products, services and markets. We can determine EV role in the SG operation. Contemporary we can distinguish following types of the EV: HEVS – hybrid electric vehicles with motor and use batteries with no using electricity from external source, Pure EVs – running on electric motor powered by batteries that are recharged by plugging in the vehicle, Plug-in PHEVs – can be charged with electricity like engine power EVs and run under engine like HEVs. The most interesting for electric power there are Pure EVs and PHEVs that are consumers and also kind of electricity storage devices (very important in SG. These types may be charged “in home”, using special station with diff erent time of charging; there is also considered charging during the time waiting for change of lights on road nodes (junctions. It is important to mention that EV development infl uence not only on SG, social- and climate- environment but also on development of new branch of industries producing equipment necessary for EV operation.

  14. A framework for analyzing the impact of data integrity/quality on electricity market operations

    Science.gov (United States)

    Choi, Dae Hyun

    This dissertation examines the impact of data integrity/quality in the supervisory control and data acquisition (SCADA) system on real-time locational marginal price (LMP) in electricity market operations. Measurement noise and/or manipulated sensor errors in a SCADA system may mislead system operators about real-time conditions in a power system, which, in turn, may impact the price signals in real-time power markets. This dissertation serves as a first attempt to analytically investigate the impact of bad/malicious data on electric power market operations. In future power system operations, which will probably involve many more sensors, the impact of sensor data integrity/quality on grid operations will become increasingly important. The first part of this dissertation studies from a market participant's perspective a new class of malicious data attacks on state estimation, which subsequently influences the result of the newly emerging look-ahead dispatch models in the real-time power market. In comparison with prior work of cyber-attack on static dispatch where no inter-temporal ramping constraint is considered, we propose a novel attack strategy, named ramp-induced data (RID) attack, with which the attacker can manipulate the limits of ramp constraints of generators in look-ahead dispatch. It is demonstrated that the proposed attack can lead to financial profits via malicious capacity withholding of selected generators, while being undetected by the existing bad data detection algorithm embedded in today's state estimation software. In the second part, we investigate from a system operator's perspective the sensitivity of locational marginal price (LMP) with respect to data corruption-induced state estimation error in real-time power market. Two data corruption scenarios are considered, in which corrupted continuous data (e.g., the power injection/flow and voltage magnitude) falsify power flow estimate whereas corrupted discrete data (e.g., the on/off status of

  15. Electricity generating system. [Wind/diesel/flywheel system

    Energy Technology Data Exchange (ETDEWEB)

    Moody, R.L.

    1992-02-05

    An electricity generating system is described which includes a water tank with electric heating elements connected to the water cooling system of a diesel engine which is heated by excess output of the system. Power in excess of that required by a load which is generated by a wind turbine driven generator runs up a flywheel and further excess is absorbed in the tank. A fan associated with a radiator connected to the tank may be operated to dissipate further excess power. When the load requirements exceed the output of the generators linked to the wind turbine and the flywheel the engine operates a synchronous alternator. (author).

  16. Technical descriptions of Hudson River electricity generating stations

    International Nuclear Information System (INIS)

    Hutchison, J.B.

    1988-01-01

    Six fossil-fueled and one nuclear electricity generating plants are sited along the Hudson River estuary between kilometers 8 and 228, measured from the river mouth. Their aggregate rated capacity is 5,798 MW of electricity; operating at that capacity they would withdraw cooling water from the river at the rate of 1.5 x 10 to the 9th power cu m/d and reject heat at the rate of 155 x 10 to the 9th power kcal/d. Three of these plants, the fossil-fueled Roseton and Bowline and the nuclear Indian Point facilities; account for 75% of total rated capacity, 62% of maximum water withdrawal, and 79% of potential heat rejection. These three plants and a proposed pumped-storage facility at Cornwall, all sited between km 60 and 106, were the focus of environmental litigation. The Indian Point plant normally operates at 100% generation capacity; the other plants may experience daily operating load changes that vary from approximately 50% to 100% of total generation capacity, depending on system electrical demand or economic considerations. All plants experience periodic unscheduled outages for repairs. 6 refs., 7 figs

  17. Quantifying the Value of Hydropower in the Electric Grid: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Key, T. [Electric Power Research Inst. (EPRI), Knovville, TN (United States); Rogers, L. [Electric Power Research Inst. (EPRI), Knovville, TN (United States); Brooks, D. [Electric Power Research Inst. (EPRI), Knovville, TN (United States); Tuohy, A. [Electric Power Research Inst. (EPRI), Knovville, TN (United States)

    2012-12-31

    The report summarizes research to Quantify the Value of Hydropower in the Electric Grid. This 3-year DOE study focused on defining value of hydropower assets in a changing electric grid. Methods are described for valuation and planning of pumped storage and conventional hydropower. The project team conducted plant case studies, electric system modeling, market analysis, cost data gathering, and evaluations of operating strategies and constraints. Five other reports detailing these research results are available a project website, www.epri.com/hydrogrid. With increasing deployment of wind and solar renewable generation, many owners, operators, and developers of hydropower have recognized the opportunity to provide more flexibility and ancillary services to the electric grid. To quantify value of services, this study focused on the Western Electric Coordinating Council region. A security-constrained, unit commitment and economic dispatch model was used to quantify the role of hydropower for several future energy scenarios up to 2020. This hourly production simulation considered transmission requirements to deliver energy, including future expansion plans. Both energy and ancillary service values were considered. Addressing specifically the quantification of pumped storage value, no single value stream dominated predicted plant contributions in various energy futures. Modeling confirmed that service value depends greatly on location and on competition with other available grid support resources. In this summary, ten different value streams related to hydropower are described. These fell into three categories; operational improvements, new technologies, and electricity market opportunities. Of these ten, the study was able to quantify a monetary value in six by applying both present day and future scenarios for operating the electric grid. This study confirmed that hydropower resources across the United States contribute significantly to operation of the grid in terms

  18. Electric power system basics for the nonelectrical professional

    CERN Document Server

    Blume, Steven W

    2016-01-01

    The second edition of Steven W. Blume’s bestseller provides a comprehensive treatment of power technology for the non-electrical engineer working in the electric power industry. This book aims to give non-electrical professionals a fundamental understanding of large interconnected electrical power systems, better known as the “Power Grid”, with regard to terminology, electrical concepts, design considerations, construction practices, industry standards, control room operations for both normal and emergency conditions, maintenance, consumption, telecommunications and safety. The text begins with an overview of the terminology and basic electrical concepts commonly used in the industry then it examines the generation, transmission and distribution of power. Other topics discussed include energy management, conservation of electrical energy, consumption characteristics and regulatory aspects to help readers understand modern electric power systems.

  19. Economic and environmental scheduling of smart homes with microgrid: DER operation and electrical tasks

    International Nuclear Information System (INIS)

    Zhang, Di; Evangelisti, Sara; Lettieri, Paola; Papageorgiou, Lazaros G.

    2016-01-01

    Highlights: • An MILP model is formulated for energy consumption scheduling among smart homes. • Environmental and economic aspects are both addressed. • The model is implemented on an example with data profiles from the UK. • Pareto-optimal curves between cost and CO_2 emissions are obtained. • Real-time pricing and critical peak pricing schemes are investigated. - Abstract: Microgrids are promising in reducing energy consumption and carbon emissions, compared with the current centralised energy generation systems. Smart homes are becoming popular for their lower energy cost and provision of comfort. Flexible energy-consuming household tasks can be scheduled co-ordinately among multiple smart homes to reduce economic cost and CO_2. However, the electricity tariff is not always positively correlated with CO_2 intensity. In this work, a mixed integer linear programming (MILP) model is proposed to schedule the energy consumption within smart homes using a microgrid system. The daily power consumption tasks are scheduled by coupling environmental and economic sustainability in a multi-objective optimisation with ε-constraint method. The two conflicting objectives are to minimise the daily energy cost and CO_2 emissions. Distributed energy resources (DER) operation and electricity-consumption household tasks are scheduled based on electricity tariff, CO_2 intensity and electricity task time window. The proposed model is implemented on a smart building of 30 homes under three different price schemes. Electricity tariff and CO_2 intensity profiles of the UK are employed for the case study. The Pareto curves for cost and CO_2 emissions present the trade-off between the two conflicting objectives.

  20. 78 FR 61389 - Sanyo Solar of Oregon, LLC, Wafer Slicing and Quality Control Operations, Including On-Site...

    Science.gov (United States)

    2013-10-03

    ..., LLC, Wafer Slicing and Quality Control Operations, Including On-Site Leased Workers From Brown and... Quality Control Operations, Salem, Oregon, including on-site leased workers from Brown and Dunton, Inc... and included workers who supplied quality control and support functions. The company reports that...

  1. Onboard power line conditioning system for an electric or hybrid vehicle

    Science.gov (United States)

    Kajouke, Lateef A.; Perisic, Milun

    2016-06-14

    A power line quality conditioning system for a vehicle includes an onboard rechargeable direct current (DC) energy storage system and an onboard electrical system coupled to the energy storage system. The energy storage system provides DC energy to drive an electric traction motor of the vehicle. The electrical system operates in a charging mode such that alternating current (AC) energy from a power grid external to the vehicle is converted to DC energy to charge the DC energy storage system. The electrical system also operates in a vehicle-to-grid power conditioning mode such that DC energy from the DC energy storage system is converted to AC energy to condition an AC voltage of the power grid.

  2. Direct electrical stimulation using a battery-operated device for induction and modulation of colonic contractions in pigs.

    Science.gov (United States)

    Bertschi, Mattia; Schlageter, Vincent; Vesin, Jean-Marc; Aellen, Steve; Peloponissios, Nicolas; D'Ambrogio, Aris; Wiesel, Paul Herman; Givel, Jean-Claude; Kucera, Pavel; Virag, Nathalie

    2010-07-01

    Direct electrical stimulation of the colon offers a promising approach for the induction of propulsive colonic contractions by using an implantable device. The objective of this study was to assess the feasibility to induce colonic contractions using a commercially available battery-operated stimulator (maximum pulse width of 1 ms and maximum amplitude of 10 V). Three pairs of pacing electrodes were inserted into the cecal seromuscular layer of anesthetized pigs. During a first set of in vivo experiments conducted on six animals, a pacing protocol leading to cecum contractions was determined: stimulation bursts with 1 ms pulse width, 10 V amplitude (7-15 mA), 120 Hz frequency, and 30-s burst duration, repeated every 2-5 min. In a second testing phase, an evaluation of the pacing protocol was performed in four animals (120 stimulation bursts in total). By using the battery-operated stimulator, contractions of the cecum and movement of contents could be induced in 92% of all stimulations. A cecal shortening of about 30% and an average intraluminal pressure increase of 10.0 +/- 6.0 mmHg were observed.

  3. A pacemaker powered by an implantable biofuel cell operating under conditions mimicking the human blood circulatory system--battery not included.

    Science.gov (United States)

    Southcott, Mark; MacVittie, Kevin; Halámek, Jan; Halámková, Lenka; Jemison, William D; Lobel, Robert; Katz, Evgeny

    2013-05-07

    Biocatalytic electrodes made of buckypaper were modified with PQQ-dependent glucose dehydrogenase on the anode and with laccase on the cathode and were assembled in a flow biofuel cell filled with serum solution mimicking the human blood circulatory system. The biofuel cell generated an open circuitry voltage, Voc, of ca. 470 mV and a short circuitry current, Isc, of ca. 5 mA (a current density of 0.83 mA cm(-2)). The power generated by the implantable biofuel cell was used to activate a pacemaker connected to the cell via a charge pump and a DC-DC converter interface circuit to adjust the voltage produced by the biofuel cell to the value required by the pacemaker. The voltage-current dependencies were analyzed for the biofuel cell connected to an Ohmic load and to the electronic loads composed of the interface circuit, or the power converter, and the pacemaker to study their operation. The correct pacemaker operation was confirmed using a medical device - an implantable loop recorder. Sustainable operation of the pacemaker was achieved with the system closely mimicking human physiological conditions using a single biofuel cell. This first demonstration of the pacemaker activated by the physiologically produced electrical energy shows promise for future electronic implantable medical devices powered by electricity harvested from the human body.

  4. Electric drives

    CERN Document Server

    Boldea, Ion

    2005-01-01

    ENERGY CONVERSION IN ELECTRIC DRIVESElectric Drives: A DefinitionApplication Range of Electric DrivesEnergy Savings Pay Off RapidlyGlobal Energy Savings Through PEC DrivesMotor/Mechanical Load MatchMotion/Time Profile MatchLoad Dynamics and StabilityMultiquadrant OperationPerformance IndexesProblemsELECTRIC MOTORS FOR DRIVESElectric Drives: A Typical ConfigurationElectric Motors for DrivesDC Brush MotorsConventional AC MotorsPower Electronic Converter Dependent MotorsEnergy Conversion in Electric Motors/GeneratorsPOWER ELECTRONIC CONVERTERS (PECs) FOR DRIVESPower Electronic Switches (PESs)The

  5. Financial statistics major US publicly owned electric utilities 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The 1996 edition of The Financial Statistics of Major US Publicly Owned Electric Utilities publication presents 5 years (1992 through 1996) of summary financial data and current year detailed financial data on the major publicly owned electric utilities. The objective of the publication is to provide Federal and State governments, industry, and the general public with current and historical data that can be used for policymaking and decision making purposes related to publicly owned electric utility issues. Generator and nongenerator summaries are presented in this publication. Five years of summary financial data are provided. Summaries of generators for fiscal years ending June 30 and December 31, nongenerators for fiscal years ending June 30 and December 31, and summaries of all respondents are provided. The composite tables present aggregates of income statement and balance sheet data, as well as financial indicators. Composite tables also display electric operation and maintenance expenses, electric utility plant, number of consumers, sales of electricity, and operating revenue, and electric energy account data. 2 figs., 32 tabs.

  6. Centrifugal compressor design for electrically assisted boost

    International Nuclear Information System (INIS)

    Yang, M Y; Martinez-Botas, R F; Zhuge, W L; Qureshi, U; Richards, B

    2013-01-01

    Electrically assisted boost is a prominent method to solve the issues of transient lag in turbocharger and remains an optimized operation condition for a compressor due to decoupling from turbine. Usually a centrifugal compressor for gasoline engine boosting is operated at high rotational speed which is beyond the ability of an electric motor in market. In this paper a centrifugal compressor with rotational speed as 120k RPM and pressure ratio as 2.0 is specially developed for electrically assisted boost. A centrifugal compressor including the impeller, vaneless diffuser and the volute is designed by meanline method followed by 3D detailed design. Then CFD method is employed to predict as well as analyse the performance of the design compressor. The results show that the pressure ratio and efficiency at design point is 2.07 and 78% specifically

  7. Coordinated Control Scheme of Battery Energy Storage System (BESS) and Distributed Generations (DGs) for Electric Distribution Grid Operation

    DEFF Research Database (Denmark)

    Cha, Seung-Tae; Zhao, Haoran; Wu, Qiuwei

    2012-01-01

    into the islanding operation mode, while the centralized joint load frequency control (CJLFC) utilizing DGs handles the secondary frequency regulation. The BESS with the associated controllers has been modelled in Real-time digital simulator (RTDS) in order to identify the improvement of the frequency and voltage......This paper describes a coordinated control scheme of battery energy storage system (BESS) and distributed generations (DGs) for electric distribution grid operation. The BESS is designed to stabilize frequency and voltages as a primary control after the electric distribution system enters...... response. The modified IEEE 9-bus system, which is comprised of several DG units, wind power plant and the BESS, has been employed to illustrate the performance of the proposed coordinated flexible control scheme using RTDS in order to verify its practical efficacy....

  8. COOPERATIVE MODE OF ELECTRIC MOTOR AND INTERNAL COMBUSTION ENGINE OPERATION IN THE CONVERSION HYBRID CAR

    Directory of Open Access Journals (Sweden)

    V. Dvadnenko

    2016-12-01

    Full Text Available In the given article the authors proposed a method to control the car, which is converted into a hybrid one. The electric motor and combustion engine operate alternately in the car. They proposed a device for implementing this method and a circuit design for the device in question. They also calculated the dynamics of the vehicle under the joint acceleration.

  9. Operating point resolved loss computation in electrical machines

    Directory of Open Access Journals (Sweden)

    Pfingsten Georg Von

    2016-03-01

    Full Text Available Magnetic circuits of electromagnetic energy converters, such as electrical machines, are nowadays highly utilized. This proposition is intrinsic for the magnetic as well as the electric circuit and depicts that significant enhancements of electrical machines are difficult to achieve in the absence of a detailed understanding of underlying effects. In order to improve the properties of electrical machines the accurate determination of the locally distributed iron losses based on idealized model assumptions solely is not sufficient. Other loss generating effects have to be considered and the possibility being able to distinguish between the causes of particular loss components is indispensable. Parasitic loss mechanisms additionally contributing to the total losses originating from field harmonics, non-linear material behaviour, rotational magnetizations, and detrimental effects caused by the manufacturing process or temperature, are not explicitly considered in the common iron-loss models, probably even not specifically contained in commonly used calibration factors. This paper presents a methodology being able to distinguish between different loss mechanisms and enables to individually consider particular loss mechanisms in the model of the electric machine. A sensitivity analysis of the model parameters can be performed to obtain information about which decisive loss origin for which working point has to be manipulated by the electromagnetic design or the control of the machine.

  10. Electricity and emission allowance markets from Finnish viewpoint. Study

    International Nuclear Information System (INIS)

    Kara, M.

    2006-05-01

    During 1995.2005 the Nordic energy system has experienced two major changes, the opening of the electricity market for competition and emissions trading within the EU. The European Union's emissions trading scheme (EU ETS) that began operating at the beginning of 2005 has weakened the competitiveness of Finnish electricity production and raised electricity prices. Most electricity producers have accumulated large profits thanks to higher prices. The payers have been nearly all electricity users. This report studies the effects of emissions trading on the electricity market and the functionality of the power market. Very little investment has been made in power production capacity in the Nordic countries over the past ten years. Considerable increases have mainly been made in Danish wind power capacity. Simultaneously, the total consumption of electricity and maximum system load have increased more than installed capacity has grown. In the next few years the power and energy balances may be threatened. In previous years, Finland has often been separated as its own market price area on the Nordic power exchange. The formation of price areas has been affected by the limited capacity in transmission interconnectors, network reparation work and the operating method of the Swedish national system operator, Svenska Kraftnaet (transferring domestic bottlenecks to the borders). This study reviews the scale of price differences and the effect on market activities. On the common Nordic electricity market, Finnish coal and peat condensing power capacity is mainly used during poor precipitation years. These plants were once built for base load production. Carbon dioxide emissions trading has further weakened the competitiveness of these plants. The biggest problem for the Nordic power exchange, Nord Pool, is regarded to be that market concentration in electricity production is high. Market concentration decreases the investment willingness of existing players as new power

  11. Dynamic Line Rating Oncor Electric Delivery Smart Grid Program

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Justin; Smith, Cale; Young, Mike; Donohoo, Ken; Owen, Ross; Clark, Eddit; Espejo, Raul; Aivaliotis, Sandy; Stelmak, Ron; Mohr, Ron; Barba, Cristian; Gonzalez, Guillermo; Malkin, Stuart; Dimitrova, Vessela; Ragsdale, Gary; Mitchem, Sean; Jeirath, Nakul; Loomis, Joe; Trevino, Gerardo; Syracuse, Steve; Hurst, Neil; Mereness, Matt; Johnson, Chad; Bivens, Carrie

    2013-05-04

    Electric transmission lines are the lifeline of the electric utility industry, delivering its product from source to consumer. This critical infrastructure is often constrained such that there is inadequate capacity on existing transmission lines to efficiently deliver the power to meet demand in certain areas or to transport energy from high-generation areas to high-consumption regions. When this happens, the cost of the energy rises; more costly sources of power are used to meet the demand or the system operates less reliably. These economic impacts are known as congestion, and they can amount to substantial dollars for any time frame of reference: hour, day or year. There are several solutions to the transmission constraint problem, including: construction of new generation, construction of new transmission facilities, rebuilding and reconductoring of existing transmission assets, and Dynamic Line Rating (DLR). All of these options except DLR are capital intensive, have long lead times and often experience strong public and regulatory opposition. The Smart Grid Demonstration Program (SGDP) project co-funded by the Department of Energy (DOE) and Oncor Electric Delivery Company developed and deployed the most extensive and advanced DLR installation to demonstrate that DLR technology is capable of resolving many transmission capacity constraint problems with a system that is reliable, safe and very cost competitive. The SGDP DLR deployment is the first application of DLR technology to feed transmission line real-time dynamic ratings directly into the system operation’s State Estimator and load dispatch program, which optimizes the matching of generation with load demand on a security, reliability and economic basis. The integrated Dynamic Line Rating (iDLR)1 collects transmission line parameters at remote locations on the lines, calculates the real-time line rating based on the equivalent conductor temperature, ambient temperature and influence of wind and solar

  12. Investment in Electricity Generation and Transmission: Decision Making Under Uncertainty

    DEFF Research Database (Denmark)

    Conejo, Antonio J.; Baringo, Luis; Kazempour, Jalal

    This book provides an in-depth analysis of investment problems pertaining to electric energy infrastructure, including both generation and transmission facilities. The analysis encompasses decision-making tools for expansion planning, reinforcement, and the selection and timing of investment...... undergraduate and graduate students in the fields of electric energy systems, operations research, management science, and economics. Practitioners in the electric energy sector will also benefit from the concepts and techniques presented here....

  13. Photonic band gap materials: towards an all-optical transistor

    Science.gov (United States)

    Florescu, Marian

    2002-05-01

    The transmission of information as optical signals encoded on light waves traveling through optical fibers and optical networks is increasingly moving to shorter and shorter distance scales. In the near future, optical networking is poised to supersede conventional transmission over electric wires and electronic networks for computer-to-computer communications, chip-to-chip communications, and even on-chip communications. The ever-increasing demand for faster and more reliable devices to process the optical signals offers new opportunities in developing all-optical signal processing systems (systems in which one optical signal controls another, thereby adding "intelligence" to the optical networks). All-optical switches, two-state and many-state all-optical memories, all-optical limiters, all-optical discriminators and all-optical transistors are only a few of the many devices proposed during the last two decades. The "all-optical" label is commonly used to distinguish the devices that do not involve dissipative electronic transport and require essentially no electrical communication of information. The all-optical transistor action was first observed in the context of optical bistability [1] and consists in a strong differential gain regime, in which, for small variations in the input intensity, the output intensity has a very strong variation. This analog operation is for all-optical input what transistor action is for electrical inputs.

  14. Operation Performance Evaluation of Power Grid Enterprise Using a Hybrid BWM-TOPSIS Method

    Directory of Open Access Journals (Sweden)

    Peipei You

    2017-12-01

    Full Text Available Electricity market reform is in progress in China, and the operational performance of power grid enterprises are vital for its healthy and sustainable development in the current electricity market environment. In this paper, a hybrid multi-criteria decision-making (MCDM framework for operational performance evaluation of a power grid enterprise is proposed from the perspective of sustainability. The latest MCDM method, namely the best-worst method (BWM was employed to determine the weights of all criteria, and the technique for order preference by similarity to an ideal solution (TOPSIS was applied to rank the operation performance of a power grid enterprise. The evaluation index system was built based on the concept of sustainability, which includes three criteria (namely economy, society, and environment and seven sub-criteria. Four power grid enterprises were selected to perform the empirical analysis, and the results indicate that power grid enterprise A1 has the best operation performance. The proposed hybrid BWM-TOPSIS-based framework for operation performance evaluation of a power grid enterprise is effective and practical.

  15. Gamma Radiation Effects on the Electrical Parameters of Some Operational Amplifiers

    International Nuclear Information System (INIS)

    Ashry, H.A.; Soliman, F.A.S.; Swidan, A.M.; El-Ghana, M.; Abdel Rahman, W.A.

    2008-01-01

    In this work, the effect of gamma-radiation on different types of operational amplifiers (HA17741 OK, HA17741 1D1, LM741 CN and μtA741 CN) was studied. It is shown that a serious effect occurs on the electrical characteristics of the op-amp's, and consequently the devices lose their main features. The input offset voltage, offset current, and bias current are shown to increase with increasing gamma dose. Also, the closed loop gain of the op-amp's is shown to decrease with increasing gamma dose, where its rate of decrease is a function of frequency. As a result, the slew rate, common mode rejection ratio and input impedance were shown to decrease with increasing gamma dose levels. On the other hand, the output impedance is inversely proportion to the gain; so, its value increases with increasing gamma exposure. Finally, it is clearly shown that the radiation dependence of the op-amp electrical parameters is a function of the fabrication technique of the op-amp's, where, the op-amps of the types HA17741 IDI and HA17741 OK are shown to be less sensitive to gamma rays than the op-amps of the types LM741 CN and μtA741 CN

  16. NLO QCD corrections to Higgs pair production including dimension-6 operators

    Energy Technology Data Exchange (ETDEWEB)

    Groeber, Ramona [INFN, Sezione di Roma Tre, Roma (Italy); Muehlleitner, Margarete; Streicher, Juraj [Karlsruher Institut fuer Technologie (KIT), Karlsruhe (Germany). Institut fuer Theoretische Physik; Spira, Michael [Paul Scherrer Institut, Villigen (Switzerland)

    2016-07-01

    The role of the Higgs boson has developed from the long-sought particle into a tool for exploring beyond Standard Model (BSM) physics. While the Higgs boson signal strengths are close to the values predicted in the Standard Model (SM), the trilinear Higgs-selfcoupling can still deviate significantly from the SM expectations in some BSM scenarios. The Effective Field Theory (EFT) framework provides a way to describe these deviations in a rather model independent way, by including higher-dimensional operators which modify the Higgs boson couplings and induce novel couplings not present in the SM. The trilinear Higgs-selfcoupling is accessible in Higgs pair production, for which the gluon fusion is the dominant production channel. The next-to-leading (NLO) QCD corrections to this process are important for a proper prediction of the cross section and are known in the limit of heavy top quark masses. In our work, we provide the NLO QCD corrections in the large top quark mass limit to Higgs pair production including dimension-6 operators. The various higher-dimensional contributions are affected differently by the QCD corrections, leading to deviations in the relative NLO QCD corrections of several per-cent, while modifying the cross section by up to an order of magnitude.

  17. Fast all-optical multistate flip-flop operation realized by a single self-sustained micro-ring laser memory cell

    International Nuclear Information System (INIS)

    Wang, Zhuoran; Yuan, Guohui

    2013-01-01

    We investigate all-optical multistate flip-flop operation realized by a single self-sustained micro-ring laser memory cell based on a time-domain multi-mode nonlinear model. Each state is written by the corresponding 100 ps-width input non-return-to-zero (NRZ) pulse carrying the directional and wavelength information, and the cell remains in the written state until another trigger arrives. The effects of key parameters including the detuning frequency and injection power ratio on the injection locking and flipping regions of different modes in both directions of the micro-ring device are studied. By optimizing the operation conditions, we simulate the minimal switching speed for each mode. The fast switching speed of less than 20 ps and up to ten mode flip-flop operation indicate that this single optical memory cell can support ten states at a data rate of at least 10 Gbps, which is particularly valuable for the realization of future all-optical networking and functional sub-system technology. (letter)

  18. Energy saving in the operation of industrial electrical substations. Part I. Studies

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Jimenez, Juan J; Zerquera Izquierdo, Mariano D; Beltran Leon, Jose S; Garcia Martinez, Juan M; Alvarez Urena, Maria V; Meza Diaz, Guillermo [Universidad de Guadalajara (Mexico)]. E-mails: cheosj@yahoo.com; mdzi@hotmail.com; beltran5601@yahoo.com.mx; jmargarmtz@yahoo.com; victory_alvarez@telmexmail.com; depmec@cucei.udg.mx

    2013-03-15

    The main objective of this work is to offer a methodology for the operation of substations composed by two or more transformers that feed loads of first category. Understand by loads of first category those in that the interruption of the electric supply may cause the loss of human life. The core of this operation shows that in substations with several transformers, the number of transformers connected at a given moment should be one that avoids losses. [Spanish] El objetivo principal de este trabajo es ofrecer una metodologia para la operacion de subestaciones compuestas por dos o mas transformadores que alimentan cargas de primera categoria. Entendiendose por cargas de primera categoria, aquellas en que la interrupcion del suministro electrico puede causar la perdida de vidas humanas. El nucleo de esta operacion muestra que en las subestaciones con varios transformadores, el numero de transformadores conectados, en un momento dado, debe ser aquel que evite perdidas.

  19. Electrically Driven Technologies for Radioactive Aerosol Abatement

    Energy Technology Data Exchange (ETDEWEB)

    David W. DePaoli; Ofodike A. Ezekoye; Costas Tsouris; Valmor F. de Almeida

    2003-01-28

    The purpose of this research project was to develop an improved understanding of how electriexecy driven processes, including electrocoalescence, acoustic agglomeration, and electric filtration, may be employed to efficiently treat problems caused by the formation of aerosols during DOE waste treatment operations. The production of aerosols during treatment and retrieval operations in radioactive waste tanks and during thermal treatment operations such as calcination presents a significant problem of cost, worker exposure, potential for release, and increased waste volume.

  20. Assessing the options for a competitive electricity market in Israel

    International Nuclear Information System (INIS)

    Tishler, A.; Newman, J.; Spekterman, I.; Woo, C.K.

    2008-01-01

    In July 2006, the Israeli government affirmed its 2003 decision to reform the Israeli electricity industry, currently dominated by the Israel Electric Corporation (IEC), a government-owned vertically integrated electric utility. The reform calls for the deregulation and privatization of the generation and customer service segments of the industry, leaving transmission and distribution (T and D) regulated to provide open access to all end-users. This paper projects the performance of the post-reform market structure for the period 2007-2030 relative to that of the status quo. The post-reform generation market's prices are determined according to the Cournot conjecture. To mitigate excessive price volatility and surges, the generation market also includes a firm that is contracted to make peak electricity sales to customers at a pre-determined price, only when the competitive price exceeds the pre-determined level. Our results show (a) the post-reform retail prices for end-users will exceed those under the status quo; (b) the post-reform profits may not be sufficient to keep firms operating combined cycle generation units financially viable; and (c) the net benefit from deregulating the electricity sector in Israel will most likely be negative. (author)