WorldWideScience

Sample records for incident non-fatal cvd

  1. [Incidence of non-fatal work-related accidents in Southeast Brazil].

    Science.gov (United States)

    Cordeiro, Ricardo; Prestes, Simone Cristina Chiodi; Clemente, Ana Paula Grotti; Diniz, Cíntia Ségre; Sakate, Mirian; Donalisio, Maria Rita

    2006-02-01

    Incidence of work-related accidents in Botucatu, São Paulo, Brazil, was estimated according to gender, age, employment status, occupation, and type of work. A household survey was conducted by systematic random group sampling (195 census tracts). Information was collected from all residents 10 years or older in each household. Of those who had worked during the 90 days prior to the interview, we obtained information on occupation, job position, and employment contract. The study included 9,626 households (sample fraction 0.26). The proportion of non-fatal work accidents in the municipal area was 3.3% (95%CI: 2.7-3.9), higher for men 4.5% (95%CI: 3.6-5.5) and varying with type of employment contract and occupation. Compared to results from previous studies, we observed a decline in work-related accident risk.

  2. Incidence of paediatric fatal and non-fatal low speed vehicle run over events in Queensland, Australia: eleven year analysis

    Science.gov (United States)

    2014-01-01

    Background The purpose of this study was to estimate the incidence of fatal and non-fatal Low Speed Vehicle Run Over (LSVRO) events among children aged 0–15 years in Queensland, Australia, at a population level. Methods Fatal and non-fatal LSVRO events that occurred in children resident in Queensland over eleven calendar years (1999-2009) were identified using ICD codes, text description, word searches and medical notes clarification, obtained from five health related data bases across the continuum of care (pre-hospital to fatality). Data were manually linked. Population data provided by the Australian Bureau of Statistics were used to calculate crude incidence rates for fatal and non-fatal LSVRO events. Results There were 1611 LSVROs between 1999–2009 (IR = 16.87/100,000/annum). Incidence of non-fatal events (IR = 16.60/100,000/annum) was 61.5 times higher than fatal events (IR = 0.27/100,000/annum). LSVRO events were more common in boys (IR = 20.97/100,000/annum) than girls (IR = 12.55/100,000/annum), and among younger children aged 0–4 years (IR = 21.45/100000/annum; 39% or all events) than older children (5–9 years: IR = 16.47/100,000/annum; 10–15 years IR = 13.59/100,000/annum). A total of 896 (56.8%) children were admitted to hospital for 24 hours of more following an LSVRO event (IR = 9.38/100,000/annum). Total LSVROs increased from 1999 (IR = 14.79/100,000) to 2009 (IR = 18.56/100,000), but not significantly. Over the 11 year period, there was a slight (non –significant) increase in fatalities (IR = 0.37-0.42/100,000/annum); a significant decrease in admissions (IR = 12.39–5.36/100,000/annum), and significant increase in non-admissions (IR = 2.02-12.77/100,000/annum). Trends over time differed by age, gender and severity. Conclusion This is the most comprehensive, population-based epidemiological study on fatal and non-fatal LSVRO events to date. Results from this study indicate

  3. Non-Fatal Injury in Thailand From 2005 to 2013: Incidence Trends and Links to Alcohol Consumption Patterns in the Thai Cohort Study

    Directory of Open Access Journals (Sweden)

    Mami Wakabayashi

    2016-09-01

    Full Text Available Background: We analyzed population-based injury trends and the association between injury and alcohol consumption patterns in Thailand, a middle-income country undergoing rapid social change. Methods: A nationwide cohort of 42 785 Thai adult Open University students, who were aged 15 to 87 years at enrolment, participated in cross-sectional assessments at baseline (2005 and 8 years later (2013. Incident non-fatal traffic and non-traffic injuries were recorded. Alcohol consumption patterns were categorized as follows: nondrinkers, occasional light drinkers, occasional heavy drinkers, regular drinkers, and ex-drinkers. Logistic regression was used to assess associations in 2005 and 2013 between injuries and alcohol consumption. We adjusted odds ratios (ORs for socio-demographic factors, stress, health behaviors, and risk-taking behaviors. Results: Incidence estimates in 2013 were standardized to the age structure of 2005: the standardized rates were 10% (95% confidence interval [CI], 9.32–9.89 for participants with at least one non-traffic injury and 5% (95% CI, 4.86–5.29 for those with at least one traffic injury. Both standardized incidences for non-traffic and traffic injuries were significantly lower than corresponding rates in 2005 (20% and 6%, respectively. Alcohol consumption was significantly associated with non-traffic injury in 2005, but the association disappeared in 2013. For example, nontraffic injury was associated with regular drinking (adjusted OR 1.17; 95% CI, 1.01–1.40 in 2005, but not in 2013 (adjusted OR 0.89; 95% CI, 0.73–1.10. In both survey years, traffic injury was not associated with occasional heavy drinking when adjusted for health and risk-taking behavior. Conclusions: We examined non-fatal injury and the health-risk transition in Thailand in 2005 and 2013. Our data revealed decreases in alcohol consumption and non-fatal injury in the Thai Cohort between 2005 and 2013. Alcoholrelated injury in Thailand today

  4. Smoking reduction, smoking cessation, and incidence of fatal and non-fatal myocardial infarction in Denmark 1976-1998

    DEFF Research Database (Denmark)

    Godtfredsen, N S; Osler, M; Vestbo, J

    2003-01-01

    information on smoking habits at two examinations five to ten years apart were followed up from the second examination for a first hospital admission or death from myocardial infarction. Mean duration of follow up was 13.8 years. MAIN RESULTS: A total of 643 participants who were heavy smokers at baseline......OBJECTIVE: To analyse the effects of smoking reduction and smoking cessation on incidence of myocardial infarction after adjustment for established cardiovascular risk factors. DESIGN: Prospective cohort study with record linkage to mortality and hospital registers. The association of individual...... change in smoking with myocardial infarction was examined in Cox proportional hazard analyses with continuous heavy smokers (> or =5 cigarettes/day) as reference. SETTING: Pooled data from three population studies conducted in Copenhagen, Denmark. PARTICIPANTS: 10 956 men and 8467 women with complete...

  5. Smoking reduction, smoking cessation, and incidence of fatal and non-fatal myocardial infarction in Denmark 1976-1998: a pooled cohort study

    DEFF Research Database (Denmark)

    Godtfredsen, N S; Osler, M; Vestbo, J

    2003-01-01

    information on smoking habits at two examinations five to ten years apart were followed up from the second examination for a first hospital admission or death from myocardial infarction. Mean duration of follow up was 13.8 years. MAIN RESULTS: A total of 643 participants who were heavy smokers at baseline......OBJECTIVE: To analyse the effects of smoking reduction and smoking cessation on incidence of myocardial infarction after adjustment for established cardiovascular risk factors. DESIGN: Prospective cohort study with record linkage to mortality and hospital registers. The association of individual...... change in smoking with myocardial infarction was examined in Cox proportional hazard analyses with continuous heavy smokers (> or =5 cigarettes/day) as reference. SETTING: Pooled data from three population studies conducted in Copenhagen, Denmark. PARTICIPANTS: 10 956 men and 8467 women with complete...

  6. Alcohol intake in relation to non-fatal and fatal coronary heart disease and stroke

    DEFF Research Database (Denmark)

    Ricci, Cristian; Wood, Angela; Muller, David

    2018-01-01

    OBJECTIVE: To investigate the association between alcohol consumption (at baseline and over lifetime) and non-fatal and fatal coronary heart disease (CHD) and stroke. DESIGN: Multicentre case-cohort study. SETTING: A study of cardiovascular disease (CVD) determinants within the European Prospecti...

  7. Non-Fatal Suicidal Behaviors in Adolescents

    OpenAIRE

    Jena, S.; Sidhartha, T.

    2004-01-01

    In the USA, suicide ranked as the third leading cause of death for adolescents in 1999. Non-fatal suicidal behaviours are suicidal thought, specific suicidal plan and suicide attempt. Prospective studies have emphasized the high subsequent suicide rates in clinically presenting suicide attempters. This study was planned to critically review the existing international literature on this area, and compare, if possible, with the Indian data. Both electronic and manual search for published and un...

  8. Repeat non-fatal suicidal behaviour at Johannesburg Hospital

    Directory of Open Access Journals (Sweden)

    M YH Moosa

    2005-12-01

    Full Text Available Objective. To describe the characteristics of non-fatal suicide behaviour (NFSB in a group of patients and to determine factors, if any, that may be associated with repetition of this behaviour. Method. The study included all patients treated for NFSB at Johannesburg Hospital during the period August 2002 - October 2002. The information was gathered by means of a structured questionnaire designed to evaluate characteristics of the behaviour. Results. The study sample comprised 43 patients with NFSB (mean age 29.7 years, range of 16 - 75 years, of whom 26 (60% were female. Sixty-three per cent of the patients overdosed with medication and 33% ingested household poisons. Events that precipitated the event included relationship problems (70%, illness (12%, financial difficulties (9%, and depressed mood (9%. In 65% of patients the behaviour was impulsive. Factors associated with non-fatal repetition included being in the 18 - 30-year age group (76% (χ2 = 6.74, p < 0.05; being female (90% (χ2 = 4.75, p < 0.05; having children (90% (χ2 = 4.72, p < 0.05; a past psychiatric history (50% (χ2 = 4.08, p < 0.05; and the current attempt deemed medically serious (50% (χ2 = 6.67, p < 0.05. Conclusions. NFSB is a major problem in South Africa and the incidence is still increasing. Hospital-based interventions following admission are recommended to reduce repeat attempts in such patients. Significant factors associated with non-fatal repetition include among others, a history of a previous medically serious attempt and/or a known psychiatric illness.

  9. Unintentional, non-fatal drowning of children: US trends and racial/ethnic disparities.

    Science.gov (United States)

    Felton, Heather; Myers, John; Liu, Gil; Davis, Deborah Winders

    2015-12-15

    The current study aimed to better understand trends and risk factors associated with non-fatal drowning of infants and children in the USA using two large, national databases. A secondary data analysis was conducted using the National Inpatient Sample and the Nationwide Emergency Department Sample databases. The analytic sample (n=19,403) included children near-drowning/non-fatal drowning. Descriptive, χ(2) and analysis of variance techniques were applied, and incidence rates were calculated per 100,000 population. Non-fatal drowning incidence has remained relatively stable from 2006 to 2011. In general, the highest rates of non-fatal drowning occurred in swimming pools and in children from racial/ethnic minorities. However, when compared with non-Hispanic Caucasian children, children from racial/ethnic minorities were more likely to drown in natural waterways than in swimming pools. Despite the overall lower rate of non-fatal drowning among non-Hispanic Caucasian children, the highest rate of all non-fatal drowning was for non-Hispanic Caucasian children aged 0-4 years in swimming pools. Children who were admitted to inpatient facilities were younger, male and came from families with lower incomes. Data from two large US national databases show lack of progress in preventing and reducing non-fatal drowning admissions from 2006 to 2011. Discrepancies are seen in the location of drowning events and demographic characteristics. New policies and interventions are needed, and tailoring approaches by age and race/ethnicity may improve their effectiveness. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Hormone replacement therapy and risk of non-fatal stroke

    DEFF Research Database (Denmark)

    Pedersen, A T; Lidegaard, O; Kreiner, S

    1997-01-01

    haemorrhage, 846 thromboembolic infarction, 321 transient ischaemic attack) and 3171 controls. FINDINGS: After adjustment for confounding variables and correction for the trend in sales of HRT preparations, no significant associations were detected between current use of unopposed oestrogen replacement...... influence on the risk of subarachnoid haemorrhage (1.22 [0.79-1.89]), intracerebral haemorrhage (1.17 [0.64-2.13]), or thromboembolic infarction (1.17 [0.92-1.47]). A significantly increased incidence of transient ischaemic attacks among former users of HRT and among current users of unopposed oestrogen may...... to some extent be explained by selection--HRT users being more aware of symptoms than non-users. INTERPRETATION: Unopposed oestrogen and combined oestrogen-progestagen replacement therapy have no influence on the risk of non-fatal thromboembolic or haemorrhagic stroke in women aged 45-64 years....

  11. Geographical variation in cardiovascular incidence: results from the British Women's Heart and Health Study

    Directory of Open Access Journals (Sweden)

    Ebrahim Shah

    2010-11-01

    Full Text Available Abstract Background Prevalence of cardiovascular disease (CVD in women shows regional variations not explained by common risk factors. Analysis of CVD incidence will provide insight into whether there is further divergence between regions with increasing age. Methods Seven-year follow-up data on 2685 women aged 59-80 (mean 69 at baseline from 23 towns in the UK were available from the British Women's Heart and Health Study. Time to fatal or non-fatal CVD was analyzed using Cox regression with adjustment for risk factors, using multiple imputation for missing values. Results Compared to South England, CVD incidence is similar in North England (HR 1.05 (95% CI 0.84, 1.31 and Scotland (0.93 (0.68, 1.27, but lower in Midlands/Wales (0.85 (0.64, 1.12. Event severity influenced regional variation, with South England showing lower fatal incident CVD than other regions, but higher non-fatal incident CVD. Kaplan-Meier plots suggested that regional divergence in CVD occurred before baseline (before mean baseline age of 69. Conclusions In women, regional differences in CVD early in adult life do not further diverge in later life. This may be due to regional differences in early detection, survivorship of women entering the study, or event severity. Targeting health care resources for CVD by geographic variation may not be appropriate for older age-groups.

  12. Non-fatal suicidal behaviour at the Johannesburg General Hospital ...

    African Journals Online (AJOL)

    Non-fatal suicidal behaviour at the Johannesburg General Hospital. ... African Journal of Psychiatry ... Patients who threaten deliberate self-harm and who have a history of previous NFSB, past psychiatric illness and physical or sexual abuse, are at a higher risk of this behaviour as compared to the general population.

  13. Population based estimates of non-fatal injuries in the capital of Iran.

    Science.gov (United States)

    Saadat, Soheil; Mafi, Mostafa; Sharif-Alhoseini, Mahdi

    2011-07-31

    Fatal injuries are at the top of the injury pyramid; however, non-fatal injuries are quite common and impose huge medical expenses on the population. Relying on hospital data will underestimate the incidence of non-fatal injuries. The aim of this study was to estimate the annual incidence and out of pocket medical expenses of all injuries in urban population of Tehran (the capital city of Iran). Using the cluster random sampling approach, a household survey of residents of greater Tehran was performed on April 2008. At randomly selected residential locations, interviewers asked one adult person to report all injuries which have occurred during the past year for all household members, as well as the type of injury, place of occurrence, the activity, cause of accidents resulting in injuries, the amount of out of pocket medical expenses for injury, and whether they referred to hospital. This study included 2,450 households residing in Tehran during 2007-8. The annual incidence of all injuries was 188.7 (180.7-196.9), significant injuries needing any medical care was 68.8 (63.7-74.2), fractures was 19.3 (16.6 - 22.4), and injuries resulted in hospitalization was 16.7 (14.2 - 19.6) per 1000 population. The annual incidence of fatal injuries was 33 (7-96) per 100,000 Population. In children aged 15 or less, the annual incidence of all injuries was 137.2 (120.0 - 155.9), significant injuries needing any medical care was 64.2 (52.2 - 78.0), fractures was 21.8 (15.0 - 30.7), and injuries resulted in hospitalization was 6.8 (3.3 - 12.5) per 1000 population. The mean out of pocket medical expense for injuries was 19.9 USD. This population based study showed that the real incidence of non-fatal injuries in the capital of Iran is more than the formal hospital-based estimates. These injuries impose non trivial medical and indirect cost on the community. The out of pocket medical expense of non-fatal injuries to Tehran population is estimated as 27 million USD per year. Effective

  14. Non-fatal occupational injuries among non-governmental employees in Malaysia.

    Science.gov (United States)

    Abas, Adinegara Bin Lutfi; Said, Abdul Razzak Bin Mohd; Mohammed, Mohammed Azman Bin Aziz; Sathiakumar, Nalini

    2011-01-01

    We analyzed data on non-fatal occupational injuries reported to Malaysia's social security organization from 2002 to 2006. There was a decrease in both the absolute number and the incidence rates of these injuries over time. About 40% of cases occurred in the manufacturing sector followed by the service (17%) and trading (17%) sectors. The agriculture sector reported the highest incidence rate (24.1/1,000), followed by the manufacturing sector subcategories of wood-product manufacturing (22.1/1,000) and non-metallic industries (20.8/1,000). Men age 40 to 59 and persons of Indian ethnicity had a greater tendency to sustain injuries. Government and non-governmental organizations should strive to develop strategies to reduce the occupational injuries targeting vulnerable groups. Enforcement of safety measures will further play an important role to ensure that both employees and employers take special precautions to address workplace hazards.

  15. Non-fatal disease burden for subtypes of depressive disorder: population-based epidemiological study.

    Science.gov (United States)

    Biesheuvel-Leliefeld, Karolien E M; Kok, Gemma D; Bockting, Claudi L H; de Graaf, Ron; Ten Have, Margreet; van der Horst, Henriette E; van Schaik, Anneke; van Marwijk, Harm W J; Smit, Filip

    2016-05-12

    Major depression is the leading cause of non-fatal disease burden. Because major depression is not a homogeneous condition, this study estimated the non-fatal disease burden for mild, moderate and severe depression in both single episode and recurrent depression. All estimates were assessed from an individual and a population perspective and presented as unadjusted, raw estimates and as estimates adjusted for comorbidity. We used data from the first wave of the second Netherlands-Mental-Health-Survey-and-Incidence-Study (NEMESIS-2, n = 6646; single episode Diagnostic and Statistical Manual (DSM)-IV depression, n = 115; recurrent depression, n = 246). Disease burden from an individual perspective was assessed as 'disability weight * time spent in depression' for each person in the dataset. From a population perspective it was assessed as 'disability weight * time spent in depression *number of people affected'. The presence of mental disorders was assessed with the Composite International Diagnostic Interview (CIDI) 3.0. Single depressive episodes emerged as a key driver of disease burden from an individual perspective. From a population perspective, recurrent depressions emerged as a key driver. These findings remained unaltered after adjusting for comorbidity. The burden of disease differs between the subtype of depression and depends much on the choice of perspective. The distinction between an individual and a population perspective may help to avoid misunderstandings between policy makers and clinicians.

  16. Non-fatal suicide attempt by intentional stab wound: Clinical management, psychiatric assessment, and multidisciplinary considerations

    Directory of Open Access Journals (Sweden)

    James M Badger

    2012-01-01

    Full Text Available Background: Suicide by means of self-inflicted stab wounds is relatively uncommon and little is known about this population and their management. Materials and Methods: Retrospective review of adult trauma patients admitted to our Level-1 trauma center between January 2005 and October 2009 for management of non-fatal, self-inflicted stab wounds. Results: Fifty-eight patients were evaluated with self-inflicted stab wounds. Four patients died due to their injuries (mortality, 7%. Of the non-fatal stab wounds, 78% were male ranging in age from 19-82 (mean: 45 years. The most common injury sites were the abdomen (46%, neck (33%, and chest (20%. In terms of operative interventions, 56% of abdominal operations were therapeutic, whereas 100% of neck and chest operations were therapeutic. When assessing for suicidal ideation, 44 patients (81% admitted to suicidal intentions whereas 10 patients (19% described "accidental" circumstances. Following psychiatric evaluation, 8 of the 10 patients with "accidental injuries" were found to be suicidal. Overall, 54 patients (98% met criteria for a formal psychiatric diagnosis with 48 patients (89% necessitating inpatient or outpatient psychiatric assistance at discharge. Conclusions: Compared to previous reports of stab wounds among trauma patients, patients with self- inflicted stab wounds may have a higher incidence of operative interventions and significant injuries depending on the stab location. When circumstances surrounding a self-inflicted stabbing are suspicious, additional interviews by psychiatric care providers may uncover a suicidal basis to the event. Given the increased incidence of psychiatric illness in this population, it is imperative to approach the suicidal patient in a multidisciplinary fashion.

  17. Non-fatal hemorrhage from pontine vascular malformations

    International Nuclear Information System (INIS)

    Yamashita, Junkoh; Aoyama, Ikuhiro; Gi, Hidefuku; Handa, Hajime

    1982-01-01

    Pontine vascular malformations have usually been found at autopsy as an incidental finding or as a cause of a fatal hemorrhage. In recent years, however, computerized tomography (CT) has made it possible to visualize these lesions while the patinents are still alive. In this paper, we report 2 cases with non-fatal hemorrhages from pontine vascular malformation. The first case was a 31-year-old housewife with cheif complaints of a sensory disturbance of the left half of the body, double vision, nausea, and vomiting of 2 weeks' duration. CT revealed a small high-density mass, which was partially slightly contrast-enhanced, in the right lower pontine tegmentum, affecting the medial and lateral lemnisci, abducens, facial and acoustic nerves, brachium pontis, medial longitudinal fasciculus, corticospinal and corticobulbar fibers, and parepontine reticular formation. The second case was a 52-year-old female clerk with chief complaints of a sensory disturbance of the right half of the body and gait disturbance of 7 months' duration. CT revealed a small high-density mass, which was partially contrast-enhanced, in the left midpontine tegmentum, affecting the medial and lateral lemnisci, lateral spinothalamic tract, ventral ascending tract of V, and brachium pontis. Although there was no evidence of subarachnoid hemorrhage, both cases were deterirating progressively, probably due to tepeated small intraparenchymal hemorrhages. They were treated by radiation therapy in order to prevent further rebleeding. Fortunately, their symptoms gradually subsided, and both of them were doing well 2 years and one and a half years respectively after radiation therapy. The value of radiation therapy for this disease entity has not yet been established, but it may be worthwhile when the symptoms are worsening and there is no other suitable treatment. (J.P.N.)

  18. Epidemiology of non-fatal cerebrovascular stroke and transient ischemic attacks in Al Quseir, Egypt

    Directory of Open Access Journals (Sweden)

    El-Tallawy HN

    2013-11-01

    Full Text Available Hamdy N El-Tallawy,1 Wafaa MA Farghaly,1 Ghaydaa A Shehata,1 Nabil M Abdel-Hakeem,2 Tarek A Rageh,1 Reda Badry,1 Mahmoud R Kandil1 1Department of Neurology and Psychiatry, Faculty of Medicine, Assiut University Hospital, 2Department of Neurology, Faculty of Medicine, Al-Azhar University, Assiut branch, Assuit, Egypt Background and purpose: Stroke is a medical emergency that can cause permanent neurological damage, complications, and disability. We aim to determine the epidemiology of non-fatal cerebrovascular stroke (CVS and transient ischemic attacks (TIAs in Al Quseir City, Red Sea, Egypt. Methods: The total population (n=33,285 was screened through a door to door study by three specialists of neurology and 15 female social workers (for demographic data collection. All suspected stroke patients were subjected to a full clinical examination, computerized tomography (CT and/or magnetic resonance imaging (MRI of their brain, blood sugar, lipogram, serum uric acid, complete blood cells, blood urea, and serum creatinine, as well as evaluated by Barthel Index and Scandinavian Stroke Scale. Carotid doppler, echocardiography, and thyroid functions were done for selected cases. Results: CVS was recorded among 130 patients out of 19,848 subjects aged 20 years and more, yielding a total prevalence of 6.55/1,000 population. From June 1, 2010 to May 31, 2011, 36 patients were recorded to have stroke within 1-year, yielding an incidence rate of 1.81/1,000. Prevalence and incidence rates were higher among males than females, and both indices increased steadily with advancing age to reach the highest prevalence (37.02/1,000 and incidence rate (9.5/1,000 among aged persons 60 years and more. Conclusion: The prevalence of non-fatal stroke in Al Quseir city (6.55/1,000 was at the lower range of that recorded in developing countries (5–10/1,000 and slightly higher than that recorded in industrialized countries (5/1,000 population. Ischemic stroke is the most

  19. Television Viewing and Incident Cardiovascular Disease: Prospective Associations and Mediation Analysis in the EPIC Norfolk Study

    Science.gov (United States)

    Wijndaele, Katrien; Brage, Søren; Besson, Hervé; Khaw, Kay-Tee; Sharp, Stephen J.; Luben, Robert; Bhaniani, Amit; Wareham, Nicholas J.; Ekelund, Ulf

    2011-01-01

    Background Although television viewing time is detrimentally associated with intermediate cardiovascular risk factors, the relationship with incident total (i.e. combined fatal and non-fatal) cardiovascular disease (CVD), non-fatal CVD and coronary heart disease is largely unknown. This study examined whether television viewing time is associated with these three outcomes, independently of physical activity energy expenditure and other confounding variables. Methodology/Principal Findings A population-based cohort of 12,608 men and women (aged 61.4±9.0), free from stroke, myocardial infarction and cancer at baseline in 1998–2000 were followed up until 2007 (6.9±1.9 years). Participants self-reported education, smoking, alcohol use, antihypertensive, lipid lowering and antidepressant medication, disease history, total energy intake, sleep duration, physical activity and television viewing. BMI, waist circumference, blood pressure, triglycerides, HDL cholesterol and glycated haemoglobin (HbA1c) were measured by standardized procedures; a clustered metabolic risk score was constructed. Every one hour/day increase in television viewing was associated with an increased hazard for total (HR = 1.06, 95%CI = 1.03–1.08; 2,620 cases), non-fatal CVD (HR = 1.06, 95%CI = 1.03–1.09; 2,134 cases), and coronary heart disease (HR = 1.08, 95%CI = 1.03–1.13; 940 cases), independent of gender, age, education, smoking, alcohol, medication, diabetes status, CVD family history, sleep duration and physical activity energy expenditure. Energy intake, BMI, waist circumference, blood pressure, triglycerides, HDL cholesterol, HbA1c and the clustered metabolic risk score only partially mediated these associations. Conclusions These results indicate that the most prevalent leisure time (sedentary) behaviour, television viewing, independently contributes to increased CVD risk. Recommendations on reducing television viewing time should be considered. PMID

  20. Non-fatal workplace violence workers' compensation claims (1993-1996).

    Science.gov (United States)

    Hashemi, L; Webster, B S

    1998-06-01

    More is known about fatal workplace violence than non-fatal workplace violence (NFWV). This study provides descriptive information on the number and cost of NFWV claims filed with a large workers' compensation carrier. NFWV claims from 51 US jurisdictions were selected either by cause codes or by word search from the accident-description narrative. Claims reported in 1993 through 1996 were analyzed to report the frequency, cost, gender, age, industry, and nature of injury. An analysis of a random sample of 600 claims provided information on perpetrator type, cause of events, and injury mechanism. A total of 28,692 NFWV claims were filed during the study period. No cost was incurred for 32.5% of the claims, and 15.5% received payments for lost work. As a percentage of all claims filed by industry, schools had the highest percentage (11.4%) of NFWV claims, and banking had the highest percentage (11.5%) of cost. The majority of claims in the banking random sample group (93%) were due to stress. In the random sample, 90.3% of claims were caused by criminals (51.8%) or by patients, clients, or customers (38.5%). Only 9.7% were caused by an employee (9.2%) or a personal acquaintance of the employee (0.5%). Employers should acknowledge that NFWV incidents occur, recognize that the majority of perpetrators are criminals or clients rather than employees, and develop appropriate prevention and intervention programs.

  1. Analyses of non-fatal accidents in an opencast mine by logistic regression model - a case study.

    Science.gov (United States)

    Onder, Seyhan; Mutlu, Mert

    2017-09-01

    Accidents cause major damage for both workers and enterprises in the mining industry. To reduce the number of occupational accidents, these incidents should be properly registered and carefully analysed. This study efficiently examines the Aegean Lignite Enterprise (ELI) of Turkish Coal Enterprises (TKI) in Soma between 2006 and 2011, and opencast coal mine occupational accident records were used for statistical analyses. A total of 231 occupational accidents were analysed for this study. The accident records were categorized into seven groups: area, reason, occupation, part of body, age, shift hour and lost days. The SPSS package program was used in this study for logistic regression analyses, which predicted the probability of accidents resulting in greater or less than 3 lost workdays for non-fatal injuries. Social facilities-area of surface installations, workshops and opencast mining areas are the areas with the highest probability for accidents with greater than 3 lost workdays for non-fatal injuries, while the reasons with the highest probability for these types of accidents are transporting and manual handling. Additionally, the model was tested for such reported accidents that occurred in 2012 for the ELI in Soma and estimated the probability of exposure to accidents with lost workdays correctly by 70%.

  2. Cause and motivation in cases of non-fatal drug overdoses in opiate addicts.

    Science.gov (United States)

    Pfab, R; Eyer, F; Jetzinger, E; Zilker, Thomas

    2006-01-01

    Drug overdose (OD) is a frequent incident among opiate addicts. Survivors of ODs are at risk for additional and eventually fatal ODs. ODs may be classified as accidental (aOD) or deliberate (dOD). Investigations into the connection between OD and suicide attempts have led to insconsistent results. (1) to determine how many non-fatal ODs were dODs and how many were aODs; (2) to determine how many cases of dODs were motivated by explicit or by ambivalent suicidal intentions; (3) to determine how many cases of aODs had causes that might respond to preventative measures; (4) to compare the addiction histories of dODs and aODs; (5) to compare the drugs causing the ODs; and (6) to compare the severity of the ODs in both groups. Prospective study utilizing a standardized questionnaire to evaluate opiate-addicted patients admitted to our treatment unit for OD. All cases underwent standardized drug testing to identify drug use patterns. Seventy-four cases of OD underwent standardized interviews after awakening. Forty-three percent of the cases were dOD. Cases of dOD had significantly more OA in substitution programs, more previous ODs, and more often consumed methadone and cocaine. Among dODs, 22.5% had suicidal intention and 9.6% were ambivalent about committing suicide; background motivations were most often conflicts with spouses. Fifty-seven percent of the cases were aOD. Cases of aODs had significantly more potential lethal intoxications and had heroin detected more frequently. aODs happened with unexpected pure heroin (46%), in combination with alcohol (36%), as relapse after abstinence (40%) or after institutionalized treatment (19%). This group should be accessible for targeted education.

  3. Non-fatal self-poisoning across age groups, in Sri Lanka.

    Science.gov (United States)

    Rajapakse, Thilini; Christensen, Helen; Cotton, Sue; Griffiths, Kathleen Margaret

    2016-02-01

    Attempted or non-fatal self-poisoning in common in Sri Lanka, but little is known about variation of psychiatric morbidity and suicidal intent across differing ages. The aim of this study was to investigate factors associated with non-fatal self-poisoning in Sri Lanka across three different age groups (namely 14-24 years, 25-34 years and ≥ 35 years). It was anticipated that the findings of the study would inform and guide development of preventive interventions for non-fatal self-poisoning in this country. 935 participants were interviewed within one week of admission to hospital for medical management of non-fatal self-poisoning, over a consecutive 14-month period. Socio-demographic factors, types of poison ingested, triggers and psychiatric morbidity was examined as a function of age. Results showed that a majority (83%) of participants were aged below 35 years. Younger participants aged aged 25-34 years, and ≥ 35 years), who were more likely to ingest pesticides. Recent interpersonal conflict was a proximal trigger seen in all age groups, but suicidal intent, depression and alcohol use disorders increased with age. The overall study findings indicate that most who carry out acts of non-fatal self-poisoning in Sri Lanka are young (aged age groups, but psychiatric morbidity and suicidal intent is higher in the older age groups, as is pesticide ingestion. Age specific interventions may be efficacious in the prevention of non-fatal self-poisoning in Sri Lanka. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Obesity and non-fatal motor vehicle crash injuries: sex difference effects.

    Science.gov (United States)

    Ma, X; Laud, P W; Pintar, F; Kim, J-E; Shih, A; Shen, W; Heymsfield, S B; Allison, D B; Zhu, S

    2011-09-01

    Obesity and motor vehicle crash (MVC) injuries are two parallel epidemics in the United States. An important unanswered question is whether there are sex differences in the associations between the presence of obesity and non-fatal MVC injuries. To further understand the association between obesity and non-fatal MVC injuries, particularly the sex differences in these relations. We examined this question by analyzing data from the 2003 to 2007 National Automotive Sampling System Crashworthiness Data System (NASS CDS). A total of 10,962 drivers who were aged 18 years or older and who survived frontal collision crashes were eligible for the study. Male drivers experienced a lower rate of overall non-fatal MVC injuries than did female drivers (38.1 versus 52.2%), but experienced a higher rate of severe injuries (0.7 versus 0.2%). After adjusting for change in velocity (ΔV) during the crashes, obese male drivers showed a much higher risk (logistic coefficients of body mass index (BMI) for moderate, serious and severe injury are 0.0766, 0.1470 and 0.1792, respectively; all Pobese male drivers and these risks increased with injury severity. Non-fatal injury risks were not found to be increased in obese female drivers. The association between obesity and risk of non-fatal injury was much stronger for male drivers than for female drivers. The higher risk of non-fatal MVC injuries in obese male drivers might result from their different body shape and fat distribution compared with obese female drivers. Our findings should be considered for obesity reduction, traffic safety evaluation and vehicle design for obese male drivers and provide testable hypotheses for future studies.

  5. Empirical validation of the New Zealand serious non-fatal injury outcome indicator for 'all injury'

    DEFF Research Database (Denmark)

    Cryer, Colin; Davie, Gabrielle S; Gulliver, Pauline J

    2018-01-01

    Our purpose was to empirically validate the official New Zealand (NZ) serious non-fatal 'all injury' indicator. To that end, we aimed to investigate the assumption that cases selected by the indicator have a high probability of admission. Using NZ hospital in-patient records, we identified serious...... injury diagnoses were calculated and inference made to New Zealand. The admission probabilities were 0.82, 0.89 and 0.90 for the regions of Canada, Denmark and Greece, respectively. This work provides evidence that the threshold set for the official New Zealand serious non-fatal injury indicator for 'all...

  6. Drugs taken in fatal and non-fatal self-poisoning : A study in South London

    NARCIS (Netherlands)

    Neeleman, J; Wessely, S

    This study compared the number and type of substances taken in deliberate self-poisoning with fatal (n=127) and non-fatal (n=521) outcome. The aims were (i) to describe substances typically involved in self-poisoning in England and Wales, (ii) to examine the role of drug 'cocktails' and (iii) to

  7. States with low non-fatal injury rates have high fatality rates and vice-versa.

    Science.gov (United States)

    Mendeloff, John; Burns, Rachel

    2013-05-01

    State-level injury rates or fatality rates are sometimes used in studies of the impact of various safety programs or other state policies. How much does the metric used affect the view of relative occupational risks among U.S. states? This paper uses a measure of severe injuries (fatalities) and of less severe injuries (non-fatal injuries with days away from work, restricted work, or job transfer-DART) to examine that issue. We looked at the correlation between the average DART injury rate (from the BLS Survey of Occupational Injuries and Illnesses) and an adjusted average fatality rate (from the BLS Census of Fatal Occupational Injuries) in the construction sector for states for 2003-2005 and for 2006-2008. The RAND Human Subjects Protection Committee determined that this study was exempt from review. The correlations between the fatal and non-fatal injury rates were between -0.30 and -0.70 for all construction and for the subsector of special trade contractors. The negative correlation was much smaller between the rate of fatal falls from heights and the rate of non-fatal falls from heights. Adjusting for differences in the industry composition of the construction sector across states had minor effects on these results. Although some have suggested that fatal and non-fatal injury rates should not necessarily be positively correlated, no one has suggested that the correlation is negative, which is what we find. We know that reported non-fatal rates are influenced by workers' compensation benefits and other factors. Fatality rates appear to be a more valid measure of risk. Efforts to explain the variations that we find should be undertaken. Copyright © 2012 Wiley Periodicals, Inc.

  8. Plasma Ceramides, Mediterranean Diet, and Incident Cardiovascular Disease in the PREDIMED Trial

    Science.gov (United States)

    Wang, Dong D.; Toledo, Estefanía; Hruby, Adela; Rosner, Bernard A.; Willett, Walter C.; Sun, Qi; Razquin, Cristina; Zheng, Yan; Ruiz-Canela, Miguel; Guasch-Ferré, Marta; Corella, Dolores; Gómez-Gracia, Enrique; Fiol, Miquel; Estruch, Ramón; Ros, Emilio; Lapetra, José; Fito, Montserrat; Aros, Fernando; Serra-Majem, Luis; Lee, Chih-Hao; Clish, Clary B.; Liang, Liming; Salas-Salvadó, Jordi; Martínez-González, Miguel A.; Hu, Frank B.

    2017-01-01

    Background Although in vitro studies and investigations in animal models and small clinical populations have suggested that ceramides may represent an intermediate link between over-nutrition and certain pathological mechanisms underlying cardiovascular disease (CVD), no prospective studies have investigated the association between plasma ceramides and risk of CVD. Methods The study population consisted of 980 participants from the PREDIMED trial, including 230 incident cases of CVD and 787 randomly selected participants at baseline (including 37 overlapping cases), followed for up to 7.4 years. Participants were randomized to a Mediterranean diet (MedDiet) supplemented with extra-virgin olive oil, a MedDiet supplemented with nuts, or a control diet. Plasma ceramide concentrations were measured on a liquid chromatography tandem mass spectrometry metabolomics platform. The primary outcome was a composite of non-fatal acute myocardial infarction, non-fatal stroke, or cardiovascular death. Hazard Ratios (HRs) were estimated with weighted Cox regression models, using Barlow weights to account for the case-cohort design. Results The multivariable HRs [95% confidence interval (CI)] comparing the extreme quartiles of plasma concentrations of C16:0, C22:0, C24:0 and C24:1 ceramides were 2.39 (1.49–3.83, P trend <0.001), 1.91 (1.21–3.01, P trend =0.003), 1.97 (1.21–3.01, P trend =0.004), and 1.73 (1.09–2.74, P trend =0.011), respectively. The ceramide score, calculated as a weighted sum of concentrations of four ceramides, was associated with a 2.18-fold higher risk of CVD across extreme quartiles (HR =2.18, 95% CI, 1.36–3.49, P trend <0.001). The association between baseline ceramide score and incident CVD varied significantly by treatment groups (P interaction =0.010). Participants with a higher ceramide score and assigned to either of the two active intervention arms of the trial showed similar CVD risk to those with a lower ceramide score, whereas participants

  9. Spatial clustering of fatal, and non-fatal, suicide in new South Wales, Australia: implications for evidence-based prevention.

    Science.gov (United States)

    Torok, Michelle; Konings, Paul; Batterham, Philip J; Christensen, Helen

    2017-10-06

    Rates of suicide appear to be increasing, indicating a critical need for more effective prevention initiatives. To increase the efficacy of future prevention initiatives, we examined the spatial distribution of suicide deaths and suicide attempts in New South Wales (NSW), Australia, to identify where high incidence 'suicide clusters' were occurring. Such clusters represent candidate regions where intervention is critically needed, and likely to have the greatest impact, thus providing an evidence-base for the targeted prioritisation of resources. Analysis is based on official suicide mortality statistics for NSW, provided by the Australian Bureau of Statistics, and hospital separations for non-fatal intentional self-harm, provided through the NSW Health Admitted Patient Data Collection at a Statistical Area 2 (SA2) geography. Geographical Information System (GIS) techniques were applied to detect suicide clusters occurring between 2005 and 2013 (aggregated), for persons aged over 5 years. The final dataset contained 5466 mortality and 86,017 non-fatal intentional self-harm cases. In total, 25 Local Government Areas were identified as primary or secondary likely candidate regions for intervention. Together, these regions contained approximately 200 SA2 level suicide clusters, which represented 46% (n = 39,869) of hospital separations and 43% (n = 2330) of suicide deaths between 2005 and 2013. These clusters primarily converged on the Eastern coastal fringe of NSW. Crude rates of suicide deaths and intentional self-harm differed at the Local Government Areas (LGA) level in NSW. There was a tendency for primary suicide clusters to occur within metropolitan and coastal regions, rather than rural areas. The findings demonstrate the importance of taking geographical variation of suicidal behaviour into account, prior to development and implementation of prevention initiatives, so that such initiatives can target key problem areas where they are likely to have

  10. A registry-based follow-up study, comparing the incidence of cardiovascular disease in native Danes and immigrants born in Turkey, Pakistan and the former Yugoslavia: do social inequalities play a role?

    Directory of Open Access Journals (Sweden)

    Andreasen Anne H

    2011-08-01

    Full Text Available Abstract Background This study compared the incidence of cardiovascular disease (CVD and acute myocardial infarction (AMI between native Danes and immigrants born in Turkey, Pakistan and the former Yugoslavia. Furthermore, we examined whether different indicators of socioeconomic status (SES, such as employment, income and housing conditions influenced potential differences. Methods In this registry-based follow-up study individuals were identified in a large database that included individuals from two major regions in Denmark, corresponding to about 60% of the Danish population. Incident cases of CVD and AMI included fatal and non-fatal events and were taken from registries. Using Cox regression models, we estimated incidence rates at 5-year follow-up. Results Immigrant men and women from Turkey and Pakistan had an increased incidence of CVD, compared with native Danish men. In the case of AMI, a similar pattern was observed; however, differences were more pronounced. Pakistanis and Turks with a shorter duration of residence had a lower incidence, compared with those of a longer residence. Generally, no notable differences were observed between former Yugoslavians and native Danes. In men, differences in CVD and AMI were reduced after adjustment for SES, in particular, among Turks regarding CVD. In women, effects were particularly reduced among Yugoslavians in the case of CVD and in Turks in the case of CVD and AMI after adjustment for SES. Conclusions In conclusion, country of birth-related differences in the incidence of CVD and AMI were observed. At least some of the differences that we uncovered were results of a socioeconomic effect. Duration of residence also played a certain role. Future studies should collect and test different indicators of SES in studies of CVD among immigrants.

  11. Estimating cost ratio distribution between fatal and non-fatal road accidents in Malaysia

    Science.gov (United States)

    Hamdan, Nurhidayah; Daud, Noorizam

    2014-07-01

    Road traffic crashes are a global major problem, and should be treated as a shared responsibility. In Malaysia, road accident tragedies kill 6,917 people and injure or disable 17,522 people in year 2012, and government spent about RM9.3 billion in 2009 which cost the nation approximately 1 to 2 percent loss of gross domestic product (GDP) reported annually. The current cost ratio for fatal and non-fatal accident used by Ministry of Works Malaysia simply based on arbitrary value of 6:4 or equivalent 1.5:1 depends on the fact that there are six factors involved in the calculation accident cost for fatal accident while four factors for non-fatal accident. The simple indication used by the authority to calculate the cost ratio is doubted since there is lack of mathematical and conceptual evidence to explain how this ratio is determined. The main aim of this study is to determine the new accident cost ratio for fatal and non-fatal accident in Malaysia based on quantitative statistical approach. The cost ratio distributions will be estimated based on Weibull distribution. Due to the unavailability of official accident cost data, insurance claim data both for fatal and non-fatal accident have been used as proxy information for the actual accident cost. There are two types of parameter estimates used in this study, which are maximum likelihood (MLE) and robust estimation. The findings of this study reveal that accident cost ratio for fatal and non-fatal claim when using MLE is 1.33, while, for robust estimates, the cost ratio is slightly higher which is 1.51. This study will help the authority to determine a more accurate cost ratio between fatal and non-fatal accident as compared to the official ratio set by the government, since cost ratio is an important element to be used as a weightage in modeling road accident related data. Therefore, this study provides some guidance tips to revise the insurance claim set by the Malaysia road authority, hence the appropriate method

  12. The Effect of Child Access Prevention Laws on Non-Fatal Gun Injuries

    OpenAIRE

    Jeff DeSimone; Sara Markowitz

    2005-01-01

    Many states have passed child access prevention (CAP) laws, which hold the gun owner responsible if a child gains access to a gun that is not securely stored. Previous CAP law research has focused exclusively on gun-related deaths even though most gun injuries are not fatal. We use annual hospital discharge data from 1988-2001 to investigate whether CAP laws decrease non-fatal gun injuries. Results from Poisson regressions that control for various hospital, county and state characteristics, i...

  13. Value of CT in the Discrimination of Fatal from Non-Fatal Stercoral Colitis

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Cheng Hsien; Huang, Chen Chin; Wang, Li Jen; Wong, Yon Cheng; Wang, Chao Jan; Lo, Wang Chak; Lin, Being Chuan; Wan, Yung Liang; Haueh, Chuen [Chang Gung Memorial Hospital, Chang Gung University, Taoyuan (China)

    2012-06-15

    Clinical presentation and physical signs may be unreliable in the diagnosis of stercoral colitis (SC). This study evaluates the value of computed tomography (CT) in distinguishing fatal from non-fatal SC. Ten patients diagnosed as SC were obtained from inter-specialist conferences. Additional 13 patients with suspected SC were identified via the Radiology Information System (RIS). These patients were divided into two groups; fatal and non-fatal SCs. Their CT images are reviewed by two board-certified radiologists blinded to the clinical data and radiographic reports. SC occurred in older patients and displayed no gender predisposition. There was significant correlation between fatal SC and CT findings of dense mucosa (p 0.017), perfusion defects (p = 0.026), ascites (p = 0.023), or abnormal gas (p = 0.033). The sensitivity, specificity, and accuracy of dense mucosa were 71%, 86%, and 81%, respectively. These figures were 75%, 79%, and 77% for perfusion defects; 75%, 80%, and 78% for ascites; and 50%, 93%, and 78% for abnormal gas, respectively. Each CT sign of mucosal sloughing and pericolonic abscess displayed high specificity of 100% and 93% for diagnosing fatal SC, respectively. However, this did not reach statistical significance in diagnosing fatal SC. CT appears to be valuable in discriminating fatal from non-fatal SC.

  14. Value of CT in the Discrimination of Fatal from Non-Fatal Stercoral Colitis

    International Nuclear Information System (INIS)

    Wu, Cheng Hsien; Huang, Chen Chin; Wang, Li Jen; Wong, Yon Cheng; Wang, Chao Jan; Lo, Wang Chak; Lin, Being Chuan; Wan, Yung Liang; Haueh, Chuen

    2012-01-01

    Clinical presentation and physical signs may be unreliable in the diagnosis of stercoral colitis (SC). This study evaluates the value of computed tomography (CT) in distinguishing fatal from non-fatal SC. Ten patients diagnosed as SC were obtained from inter-specialist conferences. Additional 13 patients with suspected SC were identified via the Radiology Information System (RIS). These patients were divided into two groups; fatal and non-fatal SCs. Their CT images are reviewed by two board-certified radiologists blinded to the clinical data and radiographic reports. SC occurred in older patients and displayed no gender predisposition. There was significant correlation between fatal SC and CT findings of dense mucosa (p 0.017), perfusion defects (p = 0.026), ascites (p = 0.023), or abnormal gas (p = 0.033). The sensitivity, specificity, and accuracy of dense mucosa were 71%, 86%, and 81%, respectively. These figures were 75%, 79%, and 77% for perfusion defects; 75%, 80%, and 78% for ascites; and 50%, 93%, and 78% for abnormal gas, respectively. Each CT sign of mucosal sloughing and pericolonic abscess displayed high specificity of 100% and 93% for diagnosing fatal SC, respectively. However, this did not reach statistical significance in diagnosing fatal SC. CT appears to be valuable in discriminating fatal from non-fatal SC.

  15. The association of atopy with incidence of ischemic heart disease, stroke, and diabetes

    DEFF Research Database (Denmark)

    Skaaby, Tea; Husemoen, Lise Lotte Nystrup; Thuesen, Betina Heinsbæk

    2015-01-01

    analyzed by Cox regression analyses with age as underlying time axis and adjusted for study cohort, gender, education, body mass index, alcohol intake, smoking habits, physical activity during leisure time, serum lipids, and blood pressure. The prevalence of atopy was 26.9 % (n = 3,994). There were 1......Allergy is a systemic inflammatory disease that could theoretically affect the risk of cardiovascular disease (CVD) and diabetes through inflammatory pathways or mast cell-induced coronary spasm. Whether allergy is associated with an increased risk of CVD and diabetes is largely unknown. We......-specific IgE positivity to inhalant allergens. The Danish National Diabetes Register enabled identification of incident diabetes. Likewise, the Danish Registry of Causes of Death and the Danish National Patient Register provided information on fatal and non-fatal ischemic heart disease and stroke. Data were...

  16. Non-fatal self-poisoning in Sri Lanka: associated triggers and motivations.

    Science.gov (United States)

    Rajapakse, Thilini; Griffiths, Kathleen Margaret; Christensen, Helen; Cotton, Sue

    2015-11-24

    Attempted or non-fatal self-poisoning is common in Sri Lanka. To date, most preventive strategies have focused on limitation of access to toxic pesticides, which has reduced the rates of fatal self-poisoning. However the ongoing phenomenon of non-fatal self-poisoning indicates the need for exploration of alternate preventive strategies. Self-poisoning in Sri Lanka has been described as impulsive, with little premeditation, but the motivations associated with this act have not been studied in depth. This research describes the triggers and motivations associated with non-fatal self-poisoning in Sri Lanka. It is anticipated that the findings would help guide future preventive strategies. Two studies were carried out, at Teaching Hospital Peradeniya, Sri Lanka, each using a different methodology - Study 1 consisted of qualitative semi-structured interviews, and Study 2 was a cross sectional survey. Both studies were conducted among those who had recently attempted self-poisoning, and explored associated triggers and motivations associated with the act of self-poisoning. There was no overlap between participants of the two studies. A total of 24 persons participated in the semi-structured interviews (Study 1), and 921 took part in the cross-sectional survey (Study 2). Interpersonal conflict was the most common trigger prior to the act of non-fatal self-poisoning. A mixture of motivations was associated with the act of self-poisoning, including intent to die, to escape, and difficulty tolerating distress associated with interpersonal conflict. Development of interpersonal skills and interpersonal problem solving skills, particularly in adolescents and young people, emerges as a key primary preventive strategy. Further, there is value in exploring and helping people to develop more adaptive strategies to cope with emotional distress associated with interpersonal conflict. While distress tolerance and interpersonal skill training strategies used in the West may be

  17. Emprego em serviços domésticos e acidentes de trabalho não fatais Housemaids and non-fatal occupational injuries

    Directory of Open Access Journals (Sweden)

    Vilma S Santana

    2003-02-01

    Full Text Available OBJETIVO: Estimar a incidência anual de acidentes não fatais de acordo com variáveis sociodemográficas e ocupacionais entre empregadas em serviços domésticos. MÉTODOS: Inquérito de base comunitária conduzido com 1.650 mulheres de 10 a 65 anos de idade, que referiram ter atividade remunerada e que compunham uma amostra aleatória por conglomerados dos domicílios da cidade de Salvador, capital da Bahia. Os dados foram obtidos por meio de questionários individuais sobre condições de vida, trabalho e saúde. Foi utilizado o teste Exato de Fisher para diferenças de freqüências. RESULTADOS: Estimou-se a incidência anual de acidentes de trabalho não fatais em 5,0%, maior entre as empregadas em serviços domésticos (7,3% do que entre as demais trabalhadoras (4,5%, diferença estatisticamente significante (pOBJECTIVE: To estimate the annual incidence of non-fatal work injuries according to sociodemographic and occupational variables among housemaids. METHODS: A community-based survey was conducted in a population of 1,650 women aged 10 to 65 years who reported a paid occupation randomly selected in a household sample of the city of Salvador, Brazil. Data was collected through individual questionnaires on living and work conditions and health status. Fisher Exact test was performed for frequency analysis. RESULTS: It was estimated an overall annual incidence of non-fatal work injuries in the study population of 5.0%, which was statistically significant (p<0.05 higher among housemaids (7.3% than in the group with other occupations (4.5%. Half of the injuries among housemaids were not related with long-term disabilities, and 38.1% women referred not being able to work for two weeks on average after the injury. CONCLUSIONS: Housemaids represent a major contingent of the work force in Brazil and other Latin America countries. The high incidence of non-fatal work injuries in this working group reveals its public health relevance and the need

  18. Factors associated with urban non-fatal road-accident severity.

    Science.gov (United States)

    Potoglou, Dimitris; Carlucci, Fabio; Cirà, Andrea; Restaino, Marialuisa

    2018-02-05

    This paper reports on the factors associated with non-fatal urban-road accident severity. Data on accidents were gathered from the local traffic police in the City of Palermo, one of the six most populated cities in Italy. Findings from a mixed-effects logistic-regression model suggest that accident severity increases when two young drivers are involved, road traffic conditions are light/normal and when vehicles crash on a two-way road or carriageway. Speeding is more likely to cause slight or serious injury even when compared to a vehicle moving towards the opposite direction of traffic. An accident during the summer is more likely to result in a slight or serious injury than an accident during the winter, which is in line with evidence from Southern Europe and the Middle East. Finally, the severity of non-fatal accident injuries in an urban area of Southern Europe was significantly associated with speeding, the age of the driver and seasonality.

  19. Preliminary Study on Non-Fatal Occupational Injury among Operational Workers in Malaysia Palm Oil Mill

    Directory of Open Access Journals (Sweden)

    Ruslan Rumaizah

    2017-01-01

    Full Text Available Non-fatal occupational injury had becoming major global concern and its consequences to safety and health would be heavily burdening. The aim of this preliminary study was to investigate the distribution of non-fatal occupational injury among specific group of workers in palm oil mill and to acknowledge potential factors of injury causation. A questionnaire survey was designed to assess injury involvement during the employment period among operational workers of palm oil mill located in Southern Peninsular Malaysia. Thirty three (n= 33 workers volunteered and completed the questionnaire. Prevalence of injury among palm oil mill workers was 39.4% with sprain and burn were the common types of injury reported. Press Plant workers reported to have high cases of injuries. Majority of workers (78.8% stated noise was the main hazard in the palm oil mill, followed by heat hazard. Press Plant was identified as one of the specific risk group in palm oil mill based on the rate of injury occurrences reported by the workers. Exposure to noise hazard was estimated to be one of the potential factors of injury causation and further study should be made to measure the risk of hazard.

  20. Metabolic syndrome, adherence to the Mediterranean diet and 10-year cardiovascular disease incidence: The ATTICA study.

    Science.gov (United States)

    Kastorini, Christina-Maria; Panagiotakos, Demosthenes B; Chrysohoou, Christina; Georgousopoulou, Ekavi; Pitaraki, Evangelia; Puddu, Paolo Emilio; Tousoulis, Dimitrios; Stefanadis, Christodoulos; Pitsavos, Christos

    2016-03-01

    To better understand the metabolic syndrome (MS) spectrum through principal components analysis and further evaluate the role of the Mediterranean diet on MS presence. During 2001-2002, 1514 men and 1528 women (>18 y) without any clinical evidence of CVD or any other chronic disease, at baseline, living in greater Athens area, Greece, were enrolled. In 2011-2012, the 10-year follow-up was performed in 2583 participants (15% of the participants were lost to follow-up). Incidence of fatal or non-fatal CVD was defined according to WHO-ICD-10 criteria. MS was defined by the National Cholesterol Education Program Adult Treatment panel III (revised NCEP ATP III) definition. Adherence to the Mediterranean diet was assessed using the MedDietScore (range 0-55). Five principal components were derived, explaining 73.8% of the total variation, characterized by the: a) body weight and lipid profile, b) blood pressure, c) lipid profile, d) glucose profile, e) inflammatory factors. All components were associated with higher likelihood of CVD incidence. After adjusting for various potential confounding factors, adherence to the Mediterranean dietary pattern for each 10% increase in the MedDietScore, was associated with 15% lower odds of CVD incidence (95%CI: 0.71-1.06). For the participants with low adherence to the Mediterranean diet all five components were significantly associated with increased likelihood of CVD incidence. However, for the ones following closely the Mediterranean pattern positive, yet not significant associations were observed. Results of the present work propose a wider MS definition, while highlighting the beneficial role of the Mediterranean dietary pattern. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Early morning awakening and nonrestorative sleep are associated with increased minor non-fatal accidents during work and leisure time.

    Science.gov (United States)

    Chiu, Hsiao-Yean; Wang, Mei-Yeh; Chang, Cheng-Kuei; Chen, Ching-Min; Chou, Kuei-Ru; Tsai, Jen-Chen; Tsai, Pei-Shan

    2014-10-01

    The relationship between a composite measure of insomnia and occupational or fatal accidents has been investigated previously; however, little is known regarding the effect of various insomnia symptoms on minor non-fatal accidents during work and leisure time. We investigated the predicting role of insomnia symptoms on minor non-fatal accidents during work and leisure time. Data from the 2005 Taiwan Social Development Trend Survey of 36,473 Taiwanese aged ≥18 years were analyzed in 2013. Insomnia symptoms, including difficulty in initiating sleep (DIS), difficulty in maintaining sleep (DMS), early morning awakening (EMA), and nonrestorative sleep (NRS) were investigated. A minor non-fatal accident was defined as any mishap such as forgetting to turn off the gas or faucets, accidental falls, and abrasions or cuts occurring during work and leisure time in the past month that do not require immediate medical attention. Multivariable logistic regression was performed to assess the odds ratios (ORs) and associated 95% confidence interval (CI) of minor non-fatal accidents (as a binary variable) for each insomnia symptom compared with those of people presenting no symptoms, while controlling for possible confounders. EMA and NRS increased the odds of minor non-fatal accidents occurring during work and leisure time (adjusted OR=1.19, 95% CI=1.08-1.32 and adjusted OR=1.27, 95% CI=1.17-1.37, respectively). EMA and NRS are two symptoms that are significantly associated with an increased likelihood of minor non-fatal accidents during work and leisure time after adjusting for of a range of covariates. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Explaining gender differences in non-fatal suicidal behaviour among adolescents: a population-based study

    Directory of Open Access Journals (Sweden)

    Roos Jeanette

    2011-07-01

    Full Text Available Abstract Background While suicide is the second leading cause of death among young people in most industrial countries, non-fatal suicidal behaviour is also a very important public health concern among adolescents. The aim of this study was to investigate gender differences in prevalence and emotional and behavioural correlates of suicidal behaviour in a representative school-based sample of adolescents. Methods A cross-sectional design was used to assess suicidal behaviour and various areas of emotional and behavioural problems by using a self-report booklet including the Youth Self-Report. One hundred sixteen schools in a region of Southern Germany agreed to participate. A representative sample of 5,512 ninth-grade students was studied. Mean age was 14.8 years (SD 0.73; 49.8% were female. Results Serious suicidal thoughts were reported by 19.8% of the female students and 10.8% of the females had ever attempted suicide. In the male group, 9.3% had a history of suicidal thoughts and 4.9% had previously attempted suicide. Internalizing emotional and behavioural problems were shown to be higher in the female group (difference of the group means 4.41 while externalizing emotional and behavioural problems slightly predominated in male students (difference of the group means -0.65. However, the total rate of emotional and behavioural problems was significantly higher in the adolescent female group (difference of the group means 4.98. Using logistic regression models with suicidal thoughts or attempted suicide as dependent variables, the pseudo-R2 of gender alone was only 2.7% or 2.3%, while it was 30% or 23.2% for emotional and behavioural problems measured by the YSR syndrome scales. By adding gender to the emotional and behavioural problems only an additional 0.3% of information could be explained. Conclusions The findings suggest that gender differences in non-fatal suicidal behaviour among adolescents can to a large extent be explained by the

  3. Fatal and non-fatal injury outcomes: results from a purposively sampled census of seven rural subdistricts in Bangladesh.

    Science.gov (United States)

    Alonge, Olakunle; Agrawal, Priyanka; Talab, Abu; Rahman, Qazi S; Rahman, Akm Fazlur; Arifeen, Shams El; Hyder, Adnan A

    2017-08-01

    90% of the global burden of injuries is borne by low-income and middle-income countries (LMICs). However, details of the injury burden in LMICs are less clear because of the scarcity of data and population-based studies. The Saving of Lives from Drowning project, implemented in rural Bangladesh, did a census on 1·2 million people to fill this gap. This Article describes the epidemiology of fatal and non-fatal injuries from the study. In this study, we used data from the baseline census conducted as part of the Saving of Lives from Drowning (SoLiD) project. The census was implemented in 51 unions from seven purposively sampled rural subdistricts of Bangladesh between June and November, 2013. Sociodemographic, injury mortality, and morbidity information were collected for the whole population in the study area. We analysed the data for descriptive measures of fatal and non-fatal injury outcomes. Age and gender distribution, socioeconomic characteristics, and injury characteristics such as external cause, intent, location, and body part affected were reported for all injury outcomes. The census covered a population of 1 169 593 from 270 387 households and 451 villages. The overall injury mortality rate was 38 deaths per 100 000 population per year, and 104 703 people sustained major non-fatal injuries over a 6-month recall period. Drowning was the leading external cause of injury death for all ages, and falls caused the most number of non-fatal injuries. Fatal injury rates were highest in children aged 1-4 years. Non-fatal injury rates were also highest in children aged 1-4 years and those aged 65 years and older. Males had more fatal and non-fatal injuries than females across all external causes except for burns. Suicide was the leading cause of injury deaths in individuals aged 15-24 years, and more than 50% of the suicides occurred in females. The home environment was the most common location for most injuries. The burden of fatal and non-fatal injuries

  4. Risk factors for non-fatal occupational injuries among construction workers: A case-control study.

    Science.gov (United States)

    Khashaba, E; El-Helaly, M; El-Gilany, A H; Motawei, S M; Foda, S

    2018-02-01

    Substance abuse is a serious problem, because it affects both workers and young people. Prevalence and consequences of cannabis abuse among construction workers in particular are not well studied in Egypt. To determine the association between non-fatal occupational injuries among construction workers and their demographic and occupational factors and to assess the frequency of cannabis abuse and its relationship to injury severity and workdays lost. A case-control study was conducted at Mansoura Emergency Hospital. Cases were 100 acutely injured male workers. A control group of 90 healthy age-matched workers was selected from 8 construction sites. Workers were interviewed, and a questionnaire was completed that included socio-demographic data, full occupational history, and causes and type of injury. Injury outcome measures included lost workdays and the injury severity score (ISS). Cannabis abuse in injured workers was monitored by preliminary testing of urine and confirmatory testing of blood. Logistic regression analysis revealed that the independent predictors of occupational injuries were rural residence, being a carpenter or painter and past history of injuries. The most common accidents were slipping falls (62%). Confirmed cannabis test was positive in 51.1% of the injured workers. Median days away from work were greater among cannabis users than non-users. The ISS was significantly higher among users compared to non-users ( p construction workers with inadequate safety measures.

  5. [Prevalence of non-fatal road traffic injuries in Mexico: results from ENSANUT 2006].

    Science.gov (United States)

    Avila-Burgos, Leticia; Medina-Solís, Carlo E; Pérez-Núñez, Ricardo; Híjar-Medina, Martha; Aracena-Genao, Belkis; Hidalgo-Solórzano, Elisa; Palma-Coca, Oswaldo

    2008-01-01

    To determine non-fatal road traffic injuries (NFRTI) prevalence and its distribution in Mexico. Data from ENSANUT Survey 2006 were used. Using simple random sampling, one adult, one adolescent and one child were selected in each household, constituting a final sample of 94,197 representing an N of 102,886,482 people. The dependent variable was the prevalence of road traffic injuries (RTI) during the 12 months prior to the survey. The general accident prevalence was 6.0%; 16.7% corresponded to NFRTI. Men in the 20 to 44 age group living in urban areas and with high socioeconomic status had a higher RTI prevalence (p<0.05). Jalisco, Aguascalientes and Sonora were states with the highest prevalence of RTI, while Guerrero, Michoacan and Oaxaca were those with the lowest. NFRTI are frequent in Mexico and they are concentrated among men in productive ages in urban areas; they are associated with socioeconomic status at the individual level and with the state's development at the population level.

  6. Non-fatal gunshot trauma among a sample of adolescents in Djibouti: prevalence and sociodemographic associations.

    Science.gov (United States)

    Wilson, Michael L; Lewis, Erin R

    2014-01-01

    Firearm trauma is the second most common cause of serious injury among adolescents in the Republic of Djibouti. The aim of this study was to explore the sociodemographic correlates of serious injury and non-fatal gunshot trauma among adolescents in Djibouti. Using multinomial logistic regression, we compared a sample of adolescents (N = 1,711) who self-reported a non-firearm-related serious injury (n = 587) and those who reported a firearm-related injury (n = 101) with non-injured participants (n = 1,023) during a 12-month recall period. Analyses targeted demographic, behavioral, social, mental health, and family factors. After adjusting for covariates, participants reporting a non-firearm-related serious injury were more likely to report having been involved in physical fights (relative risk ratio [RRR] = 145; confidence interval [CI] = [1.04, 2.02), being bullied (RRR = 2.83; CI = [2.24, 3.56]), feeling lonely (RRR = 1.48; CI = [1.11, 1.96]), having signs of depression (RRR = 1.27; CI = [1.02, 1.58]), and be truant from school (RRR = 1.68; CI = [1.25, 2.28]). Those who reported a gunshot injury recorded being bullied (RRR = 2.83; CI = [1.77, 4.53]) and physically attacked at higher rates (RRR = 1.78; CI = [1.09, 2.89]). Serious injuries, whether firearm related or not, are important threats to adolescent health in Djibouti with potentially serious health-related correlates. More research, particularly multilevel designs, are needed to explain context-relevant factors associated with serious trauma in Djibouti.

  7. Illicit use of opioid substitution drugs: prevalence, user characteristics, and the association with non-fatal overdoses.

    Science.gov (United States)

    Bretteville-Jensen, Anne Line; Lillehagen, Mats; Gjersing, Linn; Andreas, Jasmina Burdzovic

    2015-02-01

    Diversion of opioid substitution drugs (OSD) is of public concern. This study examined the prevalence, frequency, and predictors of illicit OSD use in a group of injecting drug users (IDUs) and assessed if such use was associated with non-fatal overdoses. Semi-annual cross-sectional interviews conducted in Oslo, Norway (2006-2013), from 1355 street-recruited IDUs. Hurdle, logistic, and multinomial regression models were employed. Overall, 27% reported illicit OSD use in the past four weeks; 16.8% methadone, 12.5% buprenorphine, and 2.9% both drugs. Almost 1/10 reported at least one non-fatal overdose in the past four weeks, and roughly 1/3 reported such experience in the past year. Use of additional drugs tended to be equally, or more prevalent among illicit OSD users than other IDUs. In terms of illicit OSD use being a risk factor for non-lethal overdoses, our results showed significant associations only for infrequent buprenorphine use (using once or less than once per week). Other factors associated with non-fatal overdoses included age, education, homelessness, as well as the benzodiazepines, stimulants, and heroin use. Users of diverted OSD may represent a high-risk population, as they used more additional drugs and used them more frequently than other IDUs. However, illicit OSD use may be less harmful than previously assumed. After accounting for an extensive set of covariates, only infrequent illicit buprenorphine use, but not methadone use, was associated with non-fatal overdoses. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. A non-fatal case of invasive zygomycete (Lichtheimia corymbifera) infection in an allogeneic haematopoietic cell transplant recipient

    DEFF Research Database (Denmark)

    Eickhardt, Steffen; Braendstrup, Peter; Clasen-Linde, Erik

    2013-01-01

    Post-transplant infections in allogeneic haematopoietic cell transplant (allo-HCT) recipients often have severe consequences. This is especially the case when dealing with zygomycete infections where the result is often fatal. A major problem when dealing with zygomycete infections is the need...... for an accurate and fast diagnosis as the phylum is highly resistant towards the conventional antifungals. We herein describe a non-fatal case of Lichtheimia corymbifera infection in an allo-HCT recipient....

  9. Population based case–control study of serious non-fatal motorcycle crashes

    Science.gov (United States)

    2013-01-01

    risk. The relationship between rider factors and travel speed generally will be assessed by multivariate regression methods. Discussion In the context of the changing motorcycling environment, this study will provide evidence on contemporary risk factors for serious non-fatal motorcycle crashes. PMID:23351603

  10. Causes of General Aviation Weather-Related, Non-Fatal Incidents: Analysis Using NASA Aviation Safety Reporting System Data

    Science.gov (United States)

    2010-09-01

    first, fol- lowed by detailed analysis, finishing with a recap of the same conclusions. In technical terms, this cognitively primes11 the reader and...lowering ceiling, clouds, fog, rain, rising cloud tops, merging cloud layers) b) icing c) thunderstorms d) turbulence 11 In cognitive priming... stylistic differences in the way pilots tend to handle weather. In fact, each group seems to have problems with the exact worst category of weather with

  11. Left ventricular hypertrophy and risk of fatal and non-fatal stroke EUROSTROKE: a collaborative study among research centres in Europe

    NARCIS (Netherlands)

    M.L. Bots (Michiel); J. Tuomilehto; D.E. Grobbee (Diederick); P.J. Koudstaal (Peter Jan); Y. Nikitin; J.T. Salonen; P.C. Elwood; S. Malyutina; A. Freire de Concalves; J. Sivenius; A. di Carlo; P. Lagiou

    2002-01-01

    textabstractBACKGROUND: This study investigated the association between electrocardiographically assessed left ventricular hypertrophy (LVH) and fatal, non-fatal, haemorrhagic and ischaemic stroke in four European cohorts participating in EUROSTROKE. METHODS: EUROSTROKE is a

  12. A non-fatal case of invasive zygomycete (Lichtheimia corymbifera) infection in an allogeneic haematopoietic cell transplant recipient.

    Science.gov (United States)

    Eickhardt, Steffen; Braendstrup, Peter; Clasen-Linde, Erik; Jensen, Karl E; Alhede, Morten; Bjarnsholt, Thomas; Høiby, Niels; Vindeløv, Lars; Moser, Claus

    2013-05-01

    Post-transplant infections in allogeneic haematopoietic cell transplant (allo-HCT) recipients often have severe consequences. This is especially the case when dealing with zygomycete infections where the result is often fatal. A major problem when dealing with zygomycete infections is the need for an accurate and fast diagnosis as the phylum is highly resistant towards the conventional antifungals. We herein describe a non-fatal case of Lichtheimia corymbifera infection in an allo-HCT recipient. © 2012 The Authors APMIS © 2012 APMIS.

  13. Fatal and non-fatal cardiovascular events in a general population prescribed sibutramine in New Zealand: a prospective cohort study.

    Science.gov (United States)

    Harrison-Woolrych, Mira; Ashton, Janelle; Herbison, Peter

    2010-07-01

    The cardiovascular safety of sibutramine is currently under review by medicines regulatory authorities worldwide after the SCOUT (Sibutramine Cardiovascular Outcome Trial) showed an increased risk of cardiovascular events in patients taking sibutramine. Further data regarding the cardiovascular safety of sibutramine in a general population are now required. To quantify the risk of fatal and non-fatal cardiovascular adverse events in a general population prescribed sibutramine in postmarketing use. Observational prospective cohort study of patients dispensed sibutramine during a 3-year period (2001-4) and followed up for at least 1 year after their last prescription. The study included record-linkage to national mortality datasets to identify fatal events. Postmarketing 'real-life' use of sibutramine in a general population in New Zealand. All New Zealand patients dispensed a prescription for sibutramine in a 3-year period (for whom a National Health Identification number could be validated). 15 686 patients were included in the record linkage study for fatal events. A subgroup of 9471 patients was followed up by intensive methods for non-fatal events. (i) Rate of death from all causes and from cardiovascular events; and (ii) rates of non-fatal cardiovascular adverse events. Total exposure to sibutramine for 15 686 patients in the validated cohort was 5431 treatment-years. The rate of death from all causes in this cohort was 0.13 (95% CI 0.05, 0.27) per 100 treatment-years exposure. The rate of death from a cardiovascular event was 0.07 (95% CI 0.02, 0.19) per 100 treatment-years exposure. The most frequent non-fatal cardiovascular events in the intensively followed up cohort were hypertension, palpitations, hypotensive events and tachycardia. Risk of death from a cardiovascular event in this general population of patients prescribed sibutramine was lower than has been reported in other overweight/obese populations. The results of this study suggest that further

  14. Non-fatal injuries among Pacific infants in Auckland: data from the Pacific Islands families first two years of life study.

    Science.gov (United States)

    Schluter, Philip J; Paterson, Janis; Percival, Teuila

    2006-03-01

    Child injury is the leading cause of mortality and morbidity in developed countries. While Pacific infant death rates are relatively high in New Zealand, little is known about non-fatal injury rates. We seek to describe maternally reported injury in Pacific infants aged between 0-24 months. A cohort of Pacific infants born during 2000 in Auckland, New Zealand, was followed. Maternal home interviews were conducted at 6 weeks, 12 months and 24 months postpartum and injury events were recalled. Marginal models using generalized estimating equations (GEEs) were used to analysis the longitudinal data. The inception cohort included 1398 infants at 6 weeks, 1241 infants at 12 months and 1161 infants at 24 months. The age-specific injury incidence per 1000 person-years exposure was estimated at 48 (95% CI: 23, 88) injuries for infants aged 0-6 weeks, 106 (95% CI: 88, 127) injuries for infants aged 7 weeks-12 months and 174 (95% CI: 151, 199) injuries for infants aged 13-24 months. In the multivariable GEE model, older infants (P culturally appropriate prevention strategies for all Pacific families with young children is required to reduce injury rates for Pacific infants in New Zealand.

  15. Impact of First Aid on Treatment Outcomes for Non-Fatal Injuries in Rural Bangladesh: Findings from an Injury and Demographic Census.

    Science.gov (United States)

    Hoque, Dewan Md Emdadul; Islam, Md Irteja; Sharmin Salam, Shumona; Rahman, Qazi Sadeq-Ur; Agrawal, Priyanka; Rahman, Aminur; Rahman, Fazlur; El-Arifeen, Shams; Hyder, Adnan A; Alonge, Olakunle

    2017-07-12

    Non-fatal injuries have a significant impact on disability, productivity, and economic cost, and first-aid can play an important role in improving non-fatal injury outcomes. Data collected from a census conducted as part of a drowning prevention project in Bangladesh was used to quantify the impact of first-aid provided by trained and untrained providers on non-fatal injuries. The census covered approximately 1.2 million people from 7 sub-districts of Bangladesh. Around 10% individuals reported an injury event in the six-month recall period. The most common injuries were falls (39%) and cuts injuries (23.4%). Overall, 81.7% of those with non-fatal injuries received first aid from a provider of whom 79.9% were non-medically trained. Individuals who received first-aid from a medically trained provider had more severe injuries and were 1.28 times more likely to show improvement or recover compared to those who received first-aid from an untrained provider. In Bangladesh, first-aid for non-fatal injuries are primarily provided by untrained providers. Given the large number of untrained providers and the known benefits of first aid to overcome morbidities associated with non-fatal injuries, public health interventions should be designed and implemented to train and improve skills of untrained providers.

  16. A national cohort study of parental socioeconomic status and non-fatal suicidal behaviour-the mediating role of school performance

    Directory of Open Access Journals (Sweden)

    Jablonska Beata

    2012-01-01

    Full Text Available Abstract Background A link between low parental socioeconomic status and mental health problems in offspring is well established in previous research. The mechanisms that explain this link are largely unknown. The present study investigated whether school performance was a mediating and/or moderating factor in the path between parental socioeconomic status and the risk of hospital admission for non-fatal suicidal behaviour. Methods A national cohort of 447 929 children born during 1973-1977 was followed prospectively in the National Patient Discharge Register from the end of their ninth and final year of compulsory school until 2001. Multivariate Cox proportional hazards and linear regression analyses were performed to test whether the association between parental socioeconomic status and non-fatal suicidal behaviour was mediated or moderated by school performance. Results The results of a series of multiple regression analyses, adjusted for demographic variables, revealed that school performance was as an important mediator in the relationship between parental socioeconomic status and risk of non-fatal suicidal behaviour, accounting for 60% of the variance. The hypothesized moderation of parental socioeconomic status-non-fatal suicidal behaviour relationship by school performance was not supported. Conclusions School performance is an important mediator through which parental socioeconomic status translates into a risk for non-fatal suicidal behaviour. Prevention efforts aimed to reduce socioeconomic inequalities in non-fatal suicidal behaviour among young people will need to consider socioeconomic inequalities in school performance.

  17. Epidemiology of non-fatal injuries due to external causes in ...

    African Journals Online (AJOL)

    1991-04-20

    Apr 20, 1991 ... brain injury (see Nell and Browns for a review of the incidence and causation ... latter groups, and in turn raises the question of hospital accessibility for blacks ... available, and that presentation of blacks is often delayed IQ an.

  18. CVD in nuclear energy

    International Nuclear Information System (INIS)

    Nickel, H.

    1981-08-01

    CVD-deposited pyrocarbon, especially the coatings of nuclear fuel kernels show a structure depending on many parameters such as deposition temperature, nature and pressure of the pyrolysis gas, nature of the substrate, geometry of the deposition system, etc. Because of the variety of pyrocarbon different characterization methods have been developed or qualified for this new application. Additionally classical characterization procedures are available. Beside theoretical aspects concerning the formation and deposition mechanism of pyrocarbon from the gas phase the behaviour of such coatings under irradiation with fast neutrons is discussed. (orig.) [de

  19. Different features of Vδ2 T and NK cells in fatal and non-fatal human Ebola infections.

    Science.gov (United States)

    Cimini, Eleonora; Viola, Domenico; Cabeza-Cabrerizo, Mar; Romanelli, Antonella; Tumino, Nicola; Sacchi, Alessandra; Bordoni, Veronica; Casetti, Rita; Turchi, Federica; Martini, Federico; Bore, Joseph A; Koundouno, Fara Raymond; Duraffour, Sophie; Michel, Janine; Holm, Tobias; Zekeng, Elsa Gayle; Cowley, Lauren; Garcia Dorival, Isabel; Doerrbecker, Juliane; Hetzelt, Nicole; Baum, Jonathan H J; Portmann, Jasmine; Wölfel, Roman; Gabriel, Martin; Miranda, Osvaldo; Díaz, Graciliano; Díaz, José E; Fleites, Yoel A; Piñeiro, Carlos A; Castro, Carlos M; Koivogui, Lamine; Magassouba, N'Faly; Diallo, Boubacar; Ruibal, Paula; Oestereich, Lisa; Wozniak, David M; Lüdtke, Anja; Becker-Ziaja, Beate; Capobianchi, Maria R; Ippolito, Giuseppe; Carroll, Miles W; Günther, Stephan; Di Caro, Antonino; Muñoz-Fontela, César; Agrati, Chiara

    2017-05-01

    Human Ebola infection is characterized by a paralysis of the immune system. A signature of αβ T cells in fatal Ebola infection has been recently proposed, while the involvement of innate immune cells in the protection/pathogenesis of Ebola infection is unknown. Aim of this study was to analyze γδ T and NK cells in patients from the Ebola outbreak of 2014-2015 occurred in West Africa, and to assess their association with the clinical outcome. Nineteen Ebola-infected patients were enrolled at the time of admission to the Ebola Treatment Centre in Guinea. Patients were divided in two groups on the basis of the clinical outcome. The analysis was performed by using multiparametric flow cytometry established by the European Mobile Laboratory in the field. A low frequency of Vδ2 T-cells was observed during Ebola infection, independently from the clinical outcome. Moreover, Vδ2 T-cells from Ebola patients massively expressed CD95 apoptotic marker, suggesting the involvement of apoptotic mechanisms in Vδ2 T-cell loss. Interestingly, Vδ2 T-cells from survivors expressed an effector phenotype and presented a lower expression of the CTLA-4 exhaustion marker than fatalities, suggesting a role of effector Vδ2 T-cells in the protection. Furthermore, patients with fatal Ebola infection were characterized by a lower NK cell frequency than patients with non fatal infection. In particular, both CD56bright and CD56dim NK frequency were very low both in fatal and non fatal infections, while a higher frequency of CD56neg NK cells was associated to non-fatal infections. Finally, NK activation and expression of NKp46 and CD158a were independent from clinical outcome. Altogether, the data suggest that both effector Vδ2 T-cells and NK cells may play a role in the complex network of protective response to EBOV infection. Further studies are required to characterize the protective effector functions of Vδ2 and NK cells.

  20. Different features of Vδ2 T and NK cells in fatal and non-fatal human Ebola infections.

    Directory of Open Access Journals (Sweden)

    Eleonora Cimini

    2017-05-01

    Full Text Available Human Ebola infection is characterized by a paralysis of the immune system. A signature of αβ T cells in fatal Ebola infection has been recently proposed, while the involvement of innate immune cells in the protection/pathogenesis of Ebola infection is unknown. Aim of this study was to analyze γδ T and NK cells in patients from the Ebola outbreak of 2014-2015 occurred in West Africa, and to assess their association with the clinical outcome.Nineteen Ebola-infected patients were enrolled at the time of admission to the Ebola Treatment Centre in Guinea. Patients were divided in two groups on the basis of the clinical outcome. The analysis was performed by using multiparametric flow cytometry established by the European Mobile Laboratory in the field. A low frequency of Vδ2 T-cells was observed during Ebola infection, independently from the clinical outcome. Moreover, Vδ2 T-cells from Ebola patients massively expressed CD95 apoptotic marker, suggesting the involvement of apoptotic mechanisms in Vδ2 T-cell loss. Interestingly, Vδ2 T-cells from survivors expressed an effector phenotype and presented a lower expression of the CTLA-4 exhaustion marker than fatalities, suggesting a role of effector Vδ2 T-cells in the protection. Furthermore, patients with fatal Ebola infection were characterized by a lower NK cell frequency than patients with non fatal infection. In particular, both CD56bright and CD56dim NK frequency were very low both in fatal and non fatal infections, while a higher frequency of CD56neg NK cells was associated to non-fatal infections. Finally, NK activation and expression of NKp46 and CD158a were independent from clinical outcome.Altogether, the data suggest that both effector Vδ2 T-cells and NK cells may play a role in the complex network of protective response to EBOV infection. Further studies are required to characterize the protective effector functions of Vδ2 and NK cells.

  1. Lung function and risk of fatal and non-fatal stroke. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Truelsen, T; Prescott, E; Lange, P

    2001-01-01

    results on the relation between forced expiratory volume in one second (FEV1) and risk of incident and fatal first-ever stroke. SUBJECTS AND METHODS: The analyses are based on prospective cohort data from 12 878 eligible men and women aged 45-84 years, who participated in the first health examination...... adjustment for potential confounders: sex, age, smoking, inhalation, body mass index, systolic blood pressure, triglycerides, physical activity in leisure time, education, diabetes mellitus, and antihypertensive treatment. RESULTS: We found an inverse association between FEV1 and risk of first-time stroke...

  2. The legacy of fear: is fear impacting fatal and non-fatal drowning of African American children?

    Science.gov (United States)

    Irwin, Carol C; Irwin, Richard L; Ryan, Timothy D; Drayer, Joris

    2011-01-01

    African American children’s rates for fatal and non-fatal drowning events are alarmingly elevated, with some age groups having three times the rate as compared to White peers. Adequate swimming skills are considered a protective agent toward the prevention of drowning, but marginalized youth report limited swimming ability. This research examined minority children’s and parents/caregivers’ fear of drowning as a possible variable associated with limited swimming ability. Results confirmed that there were significant racial differences concerning the fear of drowning, and adolescent African American females were notably more likely to fear drowning while swimming than any other group. The “fear of drowning” responses by parents/ caregivers of minority children were also significantly different from their White counterparts.

  3. Developing a relativities approach to valuing the prevention of non-fatal work-related accidents and ill health.

    Science.gov (United States)

    Karnon, Jonathan; Tsuchiya, Aki; Dolan, Paul

    2005-11-01

    The aim of the current explorative study is to define and test a process for the valuation of the benefits associated with the prevention of non-fatal work-related accidents and ill health. A relativities approach is adopted, and monetary values for the prevention of three forms of work-related illness are estimated. The approach involves describing relevant attributes of alternative events (accidents or occurrences of ill health), their causes, the characteristics of the relevant working population, and the number of events that are avoidable, and asking respondents to make pair wise choices between alternatives options for prevention. Indirect monetary valuations are obtained against a peg event for which a reliable valuation exists (road deaths).A series of discussion groups were held to identify relevant factors affecting potential valuations and to test the presentation of information. The predicted magnitude of responses for three-case study events (and road deaths) was estimated in a pilot study. These preliminary stages informed the final survey instrument that described five attributes in addition to a statement of the event and occupation, and the likely intervention effect, which was administered by post. Based on a small sample, the results show that virtually all respondents passed the inserted consistency test. The median respondent altered their choice according to the number of events avoided for all three comparisons, such that the estimated valuations appear sensible. Potential amendments are suggested, but the general relativities approach warrants further investigation for the valuation of non-fatal work-related accidents and ill health.

  4. Profile of non-fatal injuries due to road traffic accidents from a industrial town in India.

    Science.gov (United States)

    Bayan, Pankaj; Bhawalkar, J S; Jadhav, S L; Banerjee, Amitav

    2013-01-01

    India has one of the highest road traffic accident rates in the world. To lessen this burden, information on the contributing factors is necessary. We studied a series of cases of non-fatal road traffic accidents in two tertiary care hospitals in Pimpri, Pune, India. A total of 212 non-fatal road traffic accidents admitted over a period of one year in these two hospitals constituted the study sample. The study variables were, the gender of the accident victims, mode of accident, days of week on which the accident took place, time of day when the injury was sustained, part of the body injured, nature of injury, and self-reported reasons for the accident. data were summarized using percentages. The Chi-square test for goodness of fit was applied, to see whether there was any association between the different weekdays or time of day and the accidents. MALE : female ratio was almost 5 : 1, which was statistically significant (Chi-Square for goodness of fit = 95.11, df = 1, P accidents occurred on Sundays and Mondays and the least around midweek (Wednesday). This pattern was also statistically significant (Chi-square for goodness of fit = 30.09, df = 6, P road users contributed to almost 80% of the cases of Road Traffic Injuries (RTIs). Accidents were more likely in the time zone of 8 pm to midnight, followed by 4 pm to 8 pm (Chi-square for goodness of fit = 89.58, df = 5, P accident. Almost half (46.22%) of the injured admitted to drinking alcohol on a regular basis. Wide pavements and safe zebra crossings should be provided for pedestrians, as the highest casualty in this study were pedestrians. More accidents occurred on Sundays and Mondays and in the late evenings. Extra supervision by traffic police may be considered on Sundays / Holidays and the day following. Roads should be well lit to improve visibility after sunset.

  5. Epidemiology and trends in non-fatal self-harm in three centres in England: 2000-2007.

    Science.gov (United States)

    Bergen, Helen; Hawton, Keith; Waters, Keith; Cooper, Jayne; Kapur, Navneet

    2010-12-01

    Self-harm is a common reason for presentation to a general hospital, with a strong association with suicide. Trends in self-harm are an important indicator of community psychopathology, with resource implications for health services and relevance to suicide prevention policy. Previous reports in the UK have come largely from single centres. To investigate trends in non-fatal self-harm in six general hospitals in three centres from the Multicentre Study of Self-harm in England, and to relate these to trends in suicide. Data on self-harm presentations to general hospital emergency departments in Oxford (one), Manchester (three) and Derby (two) were analysed over the 8-year period 1 January 2000 to 31 December 2007. Rates of self-harm declined significantly over 8 years for males in three centres (Oxford: -14%; Manchester: -25%; Derby: -18%) and females in two centres (Oxford: -2% (not significant); Manchester: -13%; Derby: -17%), in keeping with national trends in suicide. A decreasing proportion and number of episodes involved self-poisoning alone, and an increasing proportion and number involved other self-injury (e.g. hanging, jumping, traffic related). Episodes involving self-cutting alone showed a slight decrease in numbers over time. Trends in alcohol use at the time of self-harm and repetition within 1 year were stable. There were decreasing rates of non-fatal self-harm over the study period that paralleled trends in suicide in England. This was reflected mainly in a decline in emergency department presentations for self-poisoning.

  6. The SU.FOL.OM3 Study: a secondary prevention trial testing the impact of supplementation with folate and B-vitamins and/or Omega-3 PUFA on fatal and non fatal cardiovascular events, design, methods and participants characteristics

    Directory of Open Access Journals (Sweden)

    Czernichow Sébastien

    2008-06-01

    Full Text Available Abstract Background During the last decades, many basic and clinical research have pointed to the role of B vitamins (folate, vitamins B6 and B12 and n-3 fatty acids as nutritional factors that might have a protective effect on the development of cardiovascular diseases (CVD. Methods/design The SU.FOL.OM3 (SUpplementation with FOlate, vitamin B6 and B12 and/or OMega-3 fatty acids trial is a randomized double-blind, placebo-controlled, secondary-prevention trial designed to test the efficacy of 5-methyl tetra-hydro-folates (5-MTHF supplementation, in combination with vitamin B6 and B12 and/or n-3 fatty acids, at nutritional doses, on fatal and non fatal ischemic CVD in a 2 × 2 factorial design. A total of 2501 patients aged between 45 and 80 years who had a past history, in the previous year, of myocardial infarction (n = 1151 or instable angina pectoris (n = 711 or an ischemic stroke (n = 639 were included. Subjects have to be supplemented and followed up for five years. Daily supplementation comprised nutritional doses of 5-MTHF (560 μg, vitamin B6 (3 mg and B12 (20 μg and/or n-3 fatty acids (600 mg with an EPA:DHA ratio of 2:1. A factorial design 2 × 2 has been applied to investigate the separate effects of the B-vitamins, and the n-3 fatty acids, as well as their interaction as compared to the placebo. The primary endpoint is a combination of myocardial infarction, ischemic stroke and cardiovascular death. Secondary endpoints are events of the composite endpoint taken separately, total mortality, and other cardiovascular events such as acute coronary syndromes, coronary revascularization, cardiac failure, arrhythmia... Conclusion Baseline socio-demographic and medical characteristics of participants are totally comparable in the four randomized groups. Trial registration Current Controlled Trials ISRCTN41926726

  7. Hair {sup 32}P measurement for body dose mapping in non-fatal exposures to fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Mianji, Fereidoun A. [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of); Iran Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of); Jafari, Sheyda; Zaryouni, Saiedeh [Bu-Ali Sina University, Faculty of Science, Hamedan (Iran, Islamic Republic of); Hajizadeh, Bardia [Iran Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of)

    2015-03-15

    Dosimetry bioassay methods are the backbone of a personal dosimetry in criticality accidents. Although methods like hair dosimetry and the use of activation foils (e.g., {sup 32}S) have been employed for decades, capabilities of different techniques, effects of hair type and neutron spectrum on the dose response, sensitivity and uncertainties of different techniques, etc., need more investigations. For this reason, the use of the {sup 32}S(n,p){sup 32}P reaction and hair samples for estimating non-fatal doses from fast neutrons was studied. The experiments were carried out with the hair samples attached on a RANDO phantom in a Cf-252 neutron field, in the dose range of about 0.05-1.15 Gy. In addition, the adequate post-accident preparation for hair samples including optimum conditioning and timing were investigated. Experimental results prove the good sensitivity and merit of the method for neutron quantification in the mentioned dose range for which other bioassay methods are of poor resolution and sensitivity. A rough estimation of the dose-response curve for Iranian hair was also derived. (orig.)

  8. The ability of an electrocardiogram to predict fatal and non-fatal cardiac events in asymptomatic middle-aged subjects.

    Science.gov (United States)

    Terho, Henri K; Tikkanen, Jani T; Kenttä, Tuomas V; Junttila, M Juhani; Aro, Aapo L; Anttonen, Olli; Kerola, Tuomas; Rissanen, Harri A; Knekt, Paul; Reunanen, Antti; Huikuri, Heikki V

    2016-11-01

    The long-term prognostic value of a standard 12-lead electrocardiogram (ECG) for predicting cardiac events in apparently healthy middle-aged subjects is not well defined. A total of 9511 middle-aged subjects (mean age 43 ± 8.2 years, 52% males) without a known cardiac disease and with a follow-up 40 years were included in the study. Fatal and non-fatal cardiac events were collected from the national registries. The predictive value of ECG was separately analyzed for 10 and 30 years. Major ECG abnormalities were classified according to the Minnesota code. Subjects with major ECG abnormalities (N = 1131) had an increased risk of cardiac death after 10-years (adjusted hazard ratio [HR] 1.7; 95% confidence interval [95% CI], 1.1-2.5, p = 0.009) and 30-years of follow-up (HR 1.3, 95% CI, 1.1-1.5, p electrocardiogram are shown to have prognostic significance for cardiac events in elderly subjects without known cardiac disease. Our results suggest that ECG abnormalities increase the risk of fatal cardiac events also in middle-aged healthy subjects.

  9. Disentangling age-gender interactions associated with risks of fatal and non-fatal road traffic injuries in the Sultanate of Oman.

    Science.gov (United States)

    Al-Aamri, Amira K; Padmadas, Sabu S; Zhang, Li-Chun; Al-Maniri, Abdullah A

    2017-01-01

    Road traffic injuries (RTIs) are the leading cause of disability-adjusted life years lost in Oman, Saudi Arabia and United Arab Emirates. Injury prevention strategies often overlook the interaction of individual and behavioural risk factors in assessing the severity of RTI outcomes. We conducted a systematic investigation of the underlying interactive effects of age and gender on the severity of fatal and non-fatal RTI outcomes in the Sultanate of Oman. We used the Royal Oman Police national database of road traffic crashes for the period 2010-2014. Our study was based on 35 785 registered incidents: of these, 10.2% fatal injuries, 6.2% serious, 27.3% moderate, 37.3% mild injuries and 19% only vehicle damage but no human injuries. We applied a generalised ordered logit regression to estimate the effect of age and gender on RTI severity, controlling for risk behaviours, personal characteristics, vehicle, road, traffic, environment conditions and geographical location. The most dominant group at risk of all types of RTIs was young male drivers. The probability of severe incapacitating injuries was the highest for drivers aged 25-29 (26.6%) years, whereas the probability of fatal injuries was the highest for those aged 20-24 (26.9%) years. Analysis of three-way interactions of age, gender and causes of crash show that overspeeding was the primary cause of different types of RTIs. In particular, the probability of fatal injuries among male drivers attributed to overspeeding ranged from 3%-6% for those aged 35 years and above to 13.4% and 17.7% for those aged 25-29 years and 20-24 years, respectively. The high burden of severe and fatal RTIs in Oman was primarily attributed to overspeed driving behaviour of young male drivers in the 20-29 years age range. Our findings highlight the critical need for designing early gender-sensitive road safety interventions targeting young male and female drivers.

  10. Fatal versus non-fatal heroin "overdose": blood morphine concentrations with fatal outcome in comparison to those of intoxicated drivers.

    Science.gov (United States)

    Meissner, Christoph; Recker, Sabine; Reiter, Arthur; Friedrich, Hans Juergen; Oehmichen, Manfred

    2002-11-05

    The study was performed to distinguish fatal from non-fatal blood concentrations of morphine. For this purpose, blood levels of free morphine and total morphine (free morphine plus morphine conjugates) in 207 cases of heroin-related deaths were compared to those in 27 drivers surviving opiate intoxication. The majority of both survivors and non-survivors were found to show a concomitant use of depressants including alcohol or stimulants. Blood morphine levels in both groups varied widely, with a large area of overlap between survivors (free morphine: 0-128 ng/ml, total morphine: 10-2,110 ng/ml) and non-survivors (free morphine: 0-2,800 ng/ml, total morphine: 33-5,000 ng/ml). Five (18.5%) survivors and 87 (42.0%) non-survivors exhibit intoxication only by morphine. In these cases, too, both groups overlapped (survivors-free morphine: 28-93 ng/ml, total morphine: 230-1,451 ng/ml; non-survivors-free morphine: 0-2,800 ng/ml, total morphine: 119-4,660 ng/ml). Although the blood levels of free or total morphine do not allow a reliable prediction of survival versus non-survival, the ratio of free/total morphine may be a criterion to distinguish lethal versus survived intoxication. The mean of the ratio of free to total morphine for all lethal cases (N=207) was 0.293, for those that survived (N=27) 0.135, in cases of intoxication only by morphine 0.250 (N=87) and 0.080 (N=5), respectively. Applying a cut-off of 0.12 for free/total morphine and performing ROC analyses, fatal outcome can be predicted in 80% of the cases correctly, whereas 16% of the survivors were classified as dead. Nevertheless, in this study, all cases with a blood concentration of 200 ng/ml and more of free morphine displayed a fatal outcome.

  11. High prevalence of non-fatal overdose among people who inject drugs in Malaysia: Correlates of overdose and implications for overdose prevention from a cross-sectional study.

    Science.gov (United States)

    Bazazi, Alexander R; Zelenev, Alexei; Fu, Jeannia J; Yee, Ilias; Kamarulzaman, Adeeba; Altice, Frederick L

    2015-07-01

    Overdose is the leading cause of death among opioid users, but no data are available on overdose among people who inject drugs in Malaysia. We present the first estimates of the prevalence and correlates of recent non-fatal overdose among people who inject drugs in Malaysia. In 2010, 460 people who inject drugs were recruited using respondent-driven sampling (RDS) in Klang Valley to assess health outcomes associated with injection drug use. Self-reported history of non-fatal overdose in the previous 6 months was the primary outcome. Sociodemographic, behavioral and structural correlates of non-fatal overdose were assessed using multivariable logistic regression. All 460 participants used opioids and nearly all (99.1%) met criteria for opioid dependence. Most injected daily (91.3%) and were male (96.3%) and ethnically Malay (90.4%). Overall, 20% of participants had overdosed in the prior 6 months, and 43.3% had ever overdosed. The RDS-adjusted estimate of the 6-month period prevalence of overdose was 12.3% (95% confidence interval [CI] 7.9-16.6%). Having injected for more years was associated with lower odds of overdose (adjusted odds ratio [AOR] 0.6 per 5 years of injection, CI: 0.5-0.7). Rushing an injection from fear of the police nearly doubled the odds of overdose (AOR 1.9, CI: 1.9-3.6). Alcohol use was associated with recent non-fatal overdose (AOR 2.1, CI: 1.1-4.2), as was methamphetamine use (AOR 2.3, CI: 1.3-4.6). When adjusting for past-month drug use, intermittent but not daily methadone use was associated with overdose (AOR 2.8, CI: 1.5-5.9). This study reveals a large, previously undocumented burden of non-fatal overdose among people who inject drugs in Malaysia and highlights the need for interventions that might reduce the risk of overdose, such as continuous opioid substitution therapy, provision of naloxone to prevent fatal overdose, treatment of polysubstance use, and working with police to improve the risk environment. Copyright © 2014 Elsevier B

  12. Evaluation of CVD silicon carbide for synchrotron radiation mirrors

    International Nuclear Information System (INIS)

    Takacs, P.Z.

    1981-07-01

    Chemical vapor deposited silicon carbide (CVD SiC) is a recent addition to the list of materials suitable for use in the harsh environment of synchrotron radiation (SR) beam lines. SR mirrors for use at normal incidence must be ultrahigh vacuum compatible, must withstand intense x-ray irradiation without surface damage, must be capable of being polished to an extremely smooth surface finish, and must maintain surface figure under thermal loading. CVD SiC exceeds the performance of conventional optical materials in all these areas. It is, however, a relatively new optical material. Few manufacturers have experience in producing optical quality material, and few opticians have experience in figuring and polishing the material. The CVD material occurs in a variety of forms, sensitively dependent upon reaction chamber production conditions. We are evaluating samples of CVD SiC obtained commercially from various manufacturers, representing a range of deposition conditions, to determine which types of CVD material are most suitable for superpolishing. At the time of this writing, samples are being polished by several commercial vendors and surface finish characteristics are being evaluated by various analytical methods

  13. Validation of a model to investigate the effects of modifying cardiovascular disease (CVD) risk factors on the burden of CVD: the rotterdam ischemic heart disease and stroke computer simulation (RISC) model.

    Science.gov (United States)

    van Kempen, Bob J H; Ferket, Bart S; Hofman, Albert; Steyerberg, Ewout W; Colkesen, Ersen B; Boekholdt, S Matthijs; Wareham, Nicholas J; Khaw, Kay-Tee; Hunink, M G Myriam

    2012-12-06

    We developed a Monte Carlo Markov model designed to investigate the effects of modifying cardiovascular disease (CVD) risk factors on the burden of CVD. Internal, predictive, and external validity of the model have not yet been established. The Rotterdam Ischemic Heart Disease and Stroke Computer Simulation (RISC) model was developed using data covering 5 years of follow-up from the Rotterdam Study. To prove 1) internal and 2) predictive validity, the incidences of coronary heart disease (CHD), stroke, CVD death, and non-CVD death simulated by the model over a 13-year period were compared with those recorded for 3,478 participants in the Rotterdam Study with at least 13 years of follow-up. 3) External validity was verified using 10 years of follow-up data from the European Prospective Investigation of Cancer (EPIC)-Norfolk study of 25,492 participants, for whom CVD and non-CVD mortality was compared. At year 5, the observed incidences (with simulated incidences in brackets) of CHD, stroke, and CVD and non-CVD mortality for the 3,478 Rotterdam Study participants were 5.30% (4.68%), 3.60% (3.23%), 4.70% (4.80%), and 7.50% (7.96%), respectively. At year 13, these percentages were 10.60% (10.91%), 9.90% (9.13%), 14.20% (15.12%), and 24.30% (23.42%). After recalibrating the model for the EPIC-Norfolk population, the 10-year observed (simulated) incidences of CVD and non-CVD mortality were 3.70% (4.95%) and 6.50% (6.29%). All observed incidences fell well within the 95% credibility intervals of the simulated incidences. We have confirmed the internal, predictive, and external validity of the RISC model. These findings provide a basis for analyzing the effects of modifying cardiovascular disease risk factors on the burden of CVD with the RISC model.

  14. CVD - main concepts, applications and restrictions

    International Nuclear Information System (INIS)

    Bliznakovska, B.; Milosevski, M.; Krawczynski, S.; Meixner, C.; Koetter, H.R.

    1993-01-01

    Despite of the fact that the existing literature covering the last two decades is plentiful with data related to CVD, this document is an attempt to provide to a reader a concise information about the nature of CVD technique at production of technologically important materials as well as to point at special references. The text is devided into three separate sections. The first section, The Main Features of CVD, is intended to give a complete comprehensive picture of the CVD technique through process description and characterization. The basic principles of thermodynamics, CVD chemical reactions classification, CVD chemical kinetics aspects and physics of CVD (with particular attention on the gas-flow phenomena) are included. As an additional aspect, in CVD unavoidable aspect however, the role of the coating/substrate compatibility on the overall process was outlined. The second section, CVD Equipment, concerns on the pecularities of the complete CVD unit pointing out the individual significances of the separate parts, i.e. pumping system, reactor chamber, control system. The aim of this section is to create to a reader a basic understanding of the arising problems but connected to be actual CVD performance. As a final goal of this review the reader's attention is turned upon the CVD applications for production of an up-to-date important class of coatings such as multilayer coatings. (orig.)

  15. NEXAFS Study of the Annealing Effect on the Local Structure of FIB-CVD DLC

    International Nuclear Information System (INIS)

    Saikubo, Akihiko; Kato, Yuri; Igaki, Jun-ya; Kanda, Kazuhiro; Matsui, Shinji; Kometani, Reo

    2007-01-01

    Annealing effect on the local structure of diamond like carbon (DLC) formed by focused ion beam-chemical vapor deposition (FIB-CVD) was investigated by the measurement of near edge x-ray absorption fine structure (NEXAFS) and energy dispersive x-ray (EDX) spectra. Carbon K edge absorption NEXAFS spectrum of FIB-CVD DLC was measured in the energy range of 275-320 eV. In order to obtain the information on the location of the gallium in the depth direction, incidence angle dependence of NEXAFS spectrum was measured in the incident angle range from 0 deg. to 60 deg. . The peak intensity corresponding to the resonance transition of 1s→σ* originating from carbon-gallium increased from the FIB-CVD DLC annealed at 200 deg. C to the FIB-CVD DLC annealed at 400 deg. C and decreased from that at 400 deg. C to that at 600 deg. C. Especially, the intensity of this peak remarkably enhanced in the NEXAFS spectrum of the FIB-CVD DLC annealed at 400 deg. C at the incident angle of 60 deg. . On the contrary, the peak intensity corresponding to the resonance transition of 1s→π* originating from carbon double bonding of emission spectrum decreased from the FIB-CVD DLC annealed at 200 deg. C to that at 400 deg. C and increased from that at 400 deg. C to that at 600 deg. C. Gallium concentration in the FIB-CVD DLC decreased from ≅2.2% of the as-deposited FIB-CVD DLC to ≅1.5% of the FIB-CVD DLC annealed at 600 deg. C from the elementary analysis using EDX. Both experimental results indicated that gallium atom departed from FIB-CVD DLC by annealing at the temperature of 600 deg. C

  16. CVD diamond detectors and dosimeters

    International Nuclear Information System (INIS)

    Manfredotti, C.; Fizzotti, F.; LoGiudice, A.; Paolini, C.; Oliviero, P.; Vittone, E.; Torino Univ., Torino

    2002-01-01

    Natural diamond, because of its well-known properties of tissue-equivalence, has recorded a wide spreading use in radiotherapy planning with electron linear accelerators. Artificial diamond dosimeters, as obtained by Chemical Vapour Deposition (CVD) could be capable to offer the same performances and they can be prepared in different volumes and shapes. The dosimeter sensitivity per unit volume may be easily proved to be better than standard ionization microchamber. We have prepared in our laboratory CVD diamond microchamber (diamond tips) in emispherical shape with an external diameter of 200 μm, which can be used both as X-ray beam profilometers and as microdosimeters for small field applications like stereotaxy and also for in vivo applications. These dosimeters, which are obtained on a wire substrate that could be either metallic or SiC or even graphite, display good performances also as ion or synchrotron X-rays detectors

  17. Incidence of road traffic accidents and pattern of injury among ...

    African Journals Online (AJOL)

    Background and Objective: Motorcyclists are at high risk of road traffic accidents and the attendant injuries, but few community-based studies have investigated the problem in Nigeria. Therefore, this study was conducted to determine the incidence of accidents and patterns of non-fatal injury among commercial motorcyclists ...

  18. Delaminated Transfer of CVD Graphene

    Science.gov (United States)

    Clavijo, Alexis; Mao, Jinhai; Tilak, Nikhil; Altvater, Michael; Andrei, Eva

    Single layer graphene is commonly synthesized by dissociation of a carbonaceous gas at high temperatures in the presence of a metallic catalyst in a process known as Chemical Vapor Deposition or CVD. Although it is possible to achieve high quality graphene by CVD, the standard transfer technique of etching away the metallic catalyst is wasteful and jeopardizes the quality of the graphene film by contamination from etchants. Thus, development of a clean transfer technique and preservation of the parent substrate remain prominent hurdles to overcome. In this study, we employ a copper pretreatment technique and optimized parameters for growth of high quality single layer graphene at atmospheric pressure. We address the transfer challenge by utilizing the adhesive properties between a polymer film and graphene to achieve etchant-free transfer of graphene films from a copper substrate. Based on this concept we developed a technique for dry delamination and transferring of graphene to hexagonal boron nitride substrates, which produced high quality graphene films while at the same time preserving the integrity of the copper catalyst for reuse. DOE-FG02-99ER45742, Ronald E. McNair Postbaccalaureate Achievement Program.

  19. Impact of on-site cardiac catheterization on resource utilization and fatal and non-fatal outcomes after acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Richard Hugues

    2006-11-01

    Full Text Available Abstract Background Patterns of care for acute myocardial infarction (AMI strongly depend on the availability of on-site cardiac catheterization facilities. Although the management found at hospitals without on-site catheterization does not lead to increased mortality, little it known about its impact on resource utilization and non-fatal outcomes. Methods We identified all patients (n = 35,289 admitted with a first AMI in the province of Quebec between January 1, 1996 and March 31, 1999 using population-based administrative databases. Medical resource utilization and non-fatal and fatal outcomes were compared among patients admitted to hospitals with and without on-site cardiac catheterization facilities. Results Cardiac catheterization and PCI were more frequently performed among patients admitted to hospitals with catheterization facilities. However, non-invasive procedures were not used more frequently at hospitals without catheterization facilities. To the contrary, echocardiography [odds ratio (OR, 2.04; 95% confidence interval (CI, 1.93–2.16] and multi-gated acquisition imaging (OR, 1.24; 95% CI, 1.17–1.32 were used more frequently at hospitals with catheterization, and exercise treadmill testing (OR, 1.02; 95% CI, 0.91–1.15 and Sestamibi/Thallium imaging (OR, 0.93; 95% CI, 0.88–0.98 were used similarly at hospitals with and without catheterization. Use of anti-ischemic medications and frequency of emergency room and physician visits, were similar at both types of institutions. Readmission rates for AMI-related cardiac complications and mortality were also similar [adjusted hazard ratio, recurrent AMI: 1.02, 95% CI, 0.89–1.16; congestive heart failure: 1.02; 95% CI, 0.90–1.15; unstable angina: 0.93; 95% CI, 0.85–1.02; mortality: 0.99; 95% CI, 0.93–1.05]. Conclusion Although on-site availability of cardiac catheterization facilities is associated with greater use of invasive cardiac procedures, non-availability of

  20. An audit of non-fatal assault injuries treated in Federal Medical Center (FMC), Nguru, north east Nigeria.

    Science.gov (United States)

    Eni, U E; Na'aya, H U; Musa, A M; Lawan, M A; Chinda, J Y

    2009-01-01

    Violent assault injuries are a frequent occurrence in the native communities of the North Eastern Nigeria. The injuries are mostly unreported, and therefore no policy towards prevention. We hope to highlight the common causes and pattern of such injuries, as well as suggest control measures in order to reduce the incidence. A retrospective review of 208 assault injury cases seen at the Accident and Emergency department of the Federal Medical Center, Nguru, between January 2002 and December 2006. All but 12 were males, giving a male to female ratio of 16:1. Most of the patients are illiterate herdsmen and farmers. The age ranged from 12 to 70 years, with a mean of 30.9 +/- 11.2 years. The peak age incidence was 30-40 years. Fighting was the most common cause, accounting for 124 (59.6%), followed by armed robbery assaults, which accounted for 75 (36.1%). Domestic abuse was the cause in 9 cases (4.3%). Arrow shot was the commonest form of assault injury in 55 (26.4%) cases, followed by matchet in 49 (23.6%), gunshot in 37 (17.8%), club/stick in 32 (15.4%) and stab wounds in 26 (12.5 %). Quarrel over farmlands used for grazing by herdsmen was the leading cause of fighting resulting in assault injuries (87), followed by quarrel over women (32)! Assault injuries are a common occurrence in the native communities of the North Eastern Nigeria. Addressing the root causes such as mapping out grazing lands in the region, community policing as well as mandatory reporting of all assault injuries to the police for appropriate legal action, will help reduce the incidence of assault injuries.

  1. Cardiovascular disease incidence and survival

    DEFF Research Database (Denmark)

    Byberg, Stine; Agyemang, Charles; Zwisler, Ann Dorthe

    2016-01-01

    Studies on cardiovascular disease (CVD) incidence and survival show varying results between different ethnic groups. Our aim was to add a new dimension by exploring the role of migrant status in combination with ethnic background on incidence of-and survival from-CVD and more specifically acute...... of some types of cardiovascular disease compared to Danish-born. Family-reunified migrants on the other hand had lower rates of CVD. All migrants had better survival than Danish-born indicating that migrants may not always be disadvantaged in health....

  2. Factors affecting the decision to hospitalise children admitted to the emergency department due to non-fatal suicide attempts by pills.

    Science.gov (United States)

    Gokalp, Gamze; Anil, Murat; Bal, Alkan; Bicilioglu, Yuksel; Kamit Can, Fulya; Anil, Ayse Berna

    2016-01-01

    Suicide attempts (SAs) in the paediatric age group represent an important cause of morbidity and mortality. Our aim was to examine the factors affecting the decision to hospitalize children with a diagnosis of non-fatal SA by pills. Children pills during 2014 were evaluated retrospectively. Patients were divided into two groups: Group-I comprised hospitalised patients and Group-II included those who were discharged from the PED. These two groups were compared in terms of clinical and demographic characteristics recorded upon PED admission. A total of 196 patients were included in the study. The number of pills taken for self-poisoning in Group-I (median: 20 pills) was higher than that in Group-II (median: 12 pills) (p pills included the amount of medication taken for the suicide attempt and the presence of psychiatric disorders, as determined by a paediatric psychiatrist during the acute phase.

  3. Use of the Trauma Embolic Scoring System (TESS) to predict symptomatic deep vein thrombosis and fatal and non-fatal pulmonary embolism in severely injured patients.

    Science.gov (United States)

    Ho, K M; Rao, S; Rittenhouse, K J; Rogers, F B

    2014-11-01

    Fatal pulmonary embolism is the third most common cause of death after major trauma. We hypothesised that the Trauma Embolic Scoring System (TESS) would have adequate calibration and discrimination in a group of severely injured trauma patients in predicting venous thromboembolism (VTE), and could be used to predict fatal and non-fatal symptomatic pulmonary embolism. Calibration and discrimination of the TESS were assessed by the slope and intercept of the calibration curve and the area under the receiver operating characteristic curve, respectively. Of the 357 patients included in the study, 74 patients (21%) developed symptomatic VTE after a median period of 14 days following injury. The TESS predicted risks of VTE were higher among patients who developed VTE than those who did not (14 versus 9%, P=0.001) and had a moderate ability to discriminate between patients who developed VTE and those who did not (area under the receiver operating characteristic curve 0.71, 95% confidence interval 0.65 to 0.77). The slope and intercept of the calibration curve were 2.76 and 0.34, respectively, suggesting that the predicted risks of VTE were not sufficiently extreme and overall, underestimated the observed risks of VTE. Using 5% predicted risk of VTE as an arbitrary cut-point, TESS had a high sensitivity and negative predictive value (both ≥0.97) in excluding fatal and non-fatal pulmonary embolism. The TESS had a reasonable ability to discriminate between patients who developed VTE and those who did not and may be useful to select different strategies to prevent VTE in severely injured patients.

  4. Economic growth and the incidence of occupational injuries in Austria.

    Science.gov (United States)

    Barth, Alfred; Winker, Robert; Ponocny-Seliger, Elisabeth; Sögner, Leopold

    2007-01-01

    The aim of this paper was to analyze the impact of economic growth measured by real gross domestic product (GDP) on the incidence of occupational injuries in Austria. The relationship between GDP and the occupational injury rate of the wage-earning population between 1955 and 2004 was analyzed using an error correction model. The sample size increased from 1.568,371 persons in 1955 to 2.656,952 in 2004. Occupational injuries were divided into fatal and non-fatal injuries. Occupational injuries (fatal and non-fatal) decreased from 8.59% to 4.08%: non-fatal injuries decreased from 8.56% to 4.07%; fatal injuries decreased from 0.03% to 0.01%. Austrian GDP increased from EUR 37.7 billion to EUR 202.8 billion (base year 1995). Statistical analysis clearly shows that a growing economy is associated with declining injury rates (fatal and non-fatal). Two mechanisms are discussed. Firstly, rising GDP is accompanied by greater investment in safer technologies and occupational safety measures. Secondly, booming economies are associated with a reduced risk of unemployment, which is already known to be a risk factor for occupational injuries. Economic development appears to have an impact on the incidence of occupational injuries in Austria. Health policy should emphasize the necessity for safety at work particularly in phases of economic slowdown.

  5. Acidentes de trabalho não fatais: diferenças de gênero e tipo de contrato de trabalho Non-fatal occupational injuries: gender and job contract differences

    Directory of Open Access Journals (Sweden)

    Vilma Santana

    2003-04-01

    Full Text Available No Brasil, trabalhadores sem vínculo formal de trabalho representam mais da metade da força de trabalho, cuja maioria é composta por mulheres. Neste estudo, estima-se a incidência anual de acidentes ocupacionais não fatais, e a sua distribuição por gênero e tipo de contrato de trabalho, em uma área urbana do Brasil. Dados provêm de um inquérito de base comunitária conduzido com uma amostra aleatória dos habitantes de Salvador, capital do Estado da Bahia. A população deste estudo compreende o total de pessoas entre 18 e 65 anos que referiram trabalho remunerado (n = 2.947. A coleta de dados baseada em entrevistas domiciliares individuais. A incidência anual de acidentes foi estimada em 5,80%, discretamente maior entre os homens (6,05% do que entre as mulheres (5,53%, ou entre trabalhadores sem contrato formal de trabalho (5,92% do que no grupo de comparação (5,67%, diferenças não estatisticamente significantes. A semelhança entre as freqüências de acidentes de trabalho entre mulheres e homens independentemente do tipo de contrato de trabalho apontam para a necessidade de maior atenção a estes eventos no sexo feminino, e entre os trabalhadores informais, amplamente ignorados nas estatísticas oficiais do país.In Brazil, workers without a formal job contract comprise more than half of the labor force, a contingent formed mainly by women. This study presents estimates of the annual incidence of non-fatal work-related injuries and their distribution by gender and type of job contract in an urban area of Brazil. This was a community-based study with a random cluster area sample of the inhabitants from the city of Salvador, capital of the State of Bahia. The study population included all individuals from 18 to 65 years of age who reported having a paid job (n = 2,947. Data were obtained through individual household interviews. The overall estimated annual incidence rate was 5.80%, with a non-statistically significant

  6. CVD diamond windows for infrared synchrotron applications

    International Nuclear Information System (INIS)

    Sussmann, R.S.; Pickles, C.S.J.; Brandon, J.R.; Wort, C.J.H.; Coe, S.E.; Wasenczuk, A.; Dodge, C.N.; Beale, A.C.; Krehan, A.J.; Dore, P.; Nucara, A.; Calvani, P.

    1998-01-01

    This paper describes the attributes that make diamond a unique material for infrared synchrotron beam experiments. New developments in diamond synthesised by Chemical Vapour Deposition (CVD) promise to extend the range of applications which have been hitherto limited by the availability and cost of large-size single-crystal diamond. Polycrystalline CVD diamond components such as large (100 mm) diameter windows with extremely good transparency over a wide spectral range are now commercially available. Properties of CVD diamond of relevance to optical applications, such as mechanical strength, thermal conductivity and absolute bulk absorption, are discussed. It is shown that although some of the properties of CVD diamond (similar to other polycrystalline industrial ceramics) are affected by the grain structure, currently produced CVD diamond optical components have the quality and performance required for numerous demanding applications

  7. CVD diamond for nuclear detection applications

    CERN Document Server

    Bergonzo, P; Tromson, D; Mer, C; Guizard, B; Marshall, R D; Foulon, F

    2002-01-01

    Chemically vapour deposited (CVD) diamond is a remarkable material for the fabrication of radiation detectors. In fact, there exist several applications where other standard semiconductor detectors do not fulfil the specific requirements imposed by corrosive, hot and/or high radiation dose environments. The improvement of the electronic properties of CVD diamond has been under intensive investigations and led to the development of a few applications that are addressing specific industrial needs. Here, we report on CVD diamond-based detector developments and we describe how this material, even though of a polycrystalline nature, is readily of great interest for applications in the nuclear industry as well as for physics experiments. Improvements in the material synthesis as well as on device fabrication especially concern the synthesis of films that do not exhibit space charge build up effects which are often encountered in CVD diamond materials and that are highly detrimental for detection devices. On a pre-i...

  8. Surface coatings deposited by CVD and PVD

    International Nuclear Information System (INIS)

    Gabriel, H.M.

    1982-01-01

    The demand for wear and corrosion protective coatings is increasing due to economic facts. Deposition processes in gas atmospheres like the CVD and PVD processes attained a tremendous importance especially in the field of the deposition of thin hard refractory and ceramic coatings. CVD and PVD processes are reviewed in detail. Some examples of coating installations are shown and numerous applications are given to demonstrate the present state of the art. (orig.) [de

  9. CVD diamond for nuclear detection applications

    International Nuclear Information System (INIS)

    Bergonzo, P.; Brambilla, A.; Tromson, D.; Mer, C.; Guizard, B.; Marshall, R.D.; Foulon, F.

    2002-01-01

    Chemically vapour deposited (CVD) diamond is a remarkable material for the fabrication of radiation detectors. In fact, there exist several applications where other standard semiconductor detectors do not fulfil the specific requirements imposed by corrosive, hot and/or high radiation dose environments. The improvement of the electronic properties of CVD diamond has been under intensive investigations and led to the development of a few applications that are addressing specific industrial needs. Here, we report on CVD diamond-based detector developments and we describe how this material, even though of a polycrystalline nature, is readily of great interest for applications in the nuclear industry as well as for physics experiments. Improvements in the material synthesis as well as on device fabrication especially concern the synthesis of films that do not exhibit space charge build up effects which are often encountered in CVD diamond materials and that are highly detrimental for detection devices. On a pre-industrial basis, CVD diamond detectors have been fabricated for nuclear industry applications in hostile environments. Such devices can operate in harsh environments and overcome limitations encountered with the standard semiconductor materials. Of these, this paper presents devices for the monitoring of the alpha activity in corrosive nuclear waste solutions, such as those encountered in nuclear fuel assembly reprocessing facilities, as well as diamond-based thermal neutron detectors exhibiting a high neutron to gamma selectivity. All these demonstrate the effectiveness of a demanding industrial need that relies on the remarkable resilience of CVD diamond

  10. Fermented dairy food and CVD risk.

    Science.gov (United States)

    Tapsell, Linda C

    2015-04-01

    Fermented dairy foods such as yoghurt and cheese are commonly found in the Mediterranean diet. Recent landmark research has confirmed the effect of the Mediterranean diet on reducing the CVD risk, but the relative contributions of fermented dairy foods have not been fully articulated. The present study provides a review of the relationship between fermented dairy foods consumption and CVD risk in the context of the whole diet. Studies show that people who eat healthier diets may be more likely to consume yoghurt, so there is a challenge in attributing separate effects to yoghurt. Analyses from large population studies list yoghurt as the food most negatively associated with the risk of weight gain (a problem that may lead to CVD). There is some suggestion that fermented dairy foods consumption (yoghurt or cheese) may be associated with reduced inflammatory biomarkers associated with the development of CVD. Dietary trials suggest that cheese may not have the same effect on raising LDL-cholesterol levels as butter with the same saturated fat content. The same might be stated for yoghurt. The use of different probiotic cultures and other aspects of study design remain a problem for research. Nevertheless, population studies from a range of countries have shown that a reduced risk of CVD occurs with the consumption of fermented dairy foods. A combination of evidence is necessary, and more research is always valuable, but indications remain that fermented dairy foods such as cheese and yoghurt are integral to diets that are protective against CVD.

  11. The Economic Cost of Suicide and Non-Fatal Suicide Behavior in the Australian Workforce and the Potential Impact of a Workplace Suicide Prevention Strategy.

    Science.gov (United States)

    Kinchin, Irina; Doran, Christopher M

    2017-03-27

    Suicide and non-fatal suicide behavior (NFSB) are significant problems faced by most countries. The objective of this research is to quantify the economic cost of suicide and NFSB in the Australian workforce and to examine the potential impact of introducing a workplace suicide prevention intervention to reduce this burden. The analysis used the best available suicide data, a well-established costing methodology, and a proven workplace intervention. In 2014, 903 workers died by suicide, 2303 workers harmed themselves resulting in full incapacity, and 11,242 workers harmed themselves resulting in a short absence from work. The present value of the economic cost of suicide and NFSB is estimated at $6.73 billion. Our analysis suggests the economic benefit of implementing a universal workplace strategy would considerably outweigh the cost of the strategy. For every one dollar invested, the benefits would be in excess of $1.50 ($1.11-$3.07), representing a positive economic investment. All variations of the key parameter hold the positive benefit-cost ratio. Rates of suicide and NFSB are far too high in Australia and elsewhere. More needs to be done to reduce this burden. Although workplace strategies are appropriate for those employed, these interventions must be used within a multifaceted approach that reflects the complex nature of self-harming behavior.

  12. [Risk of fatal/non-fatal events in patients with previous coronary heart disease/acute myocardial infarction and treatment with non-steroidal anti-inflammatory drugs].

    Science.gov (United States)

    Muñoz Olmo, L; Juan Armas, J; Gomariz García, J J

    2017-09-04

    Primary Care is the fundamental axis of our health system and obliges us to be consistent with our prescriptions. The non-steroidal anti-inflammatory drugs (NSAIDs) have been associated with increased cardiovascular risk and increased risk of all causes of death, as well as acute myocardial infarction (AMI) in patients with a previous myocardial infarction. Pain and cardiac patient management are 2 basic pillars in our daily activity, and we must know the limitations of NSAIDs in patients with established cardiovascular risk. We present a review of the scientific literature with primary interest in the role of NSAIDs and cardiovascular risk. The objective is to determine the relationship between the consumption of different NSAIDs and the fatal and non-fatal events among patients with known coronary disease. This is a review of the scientific literature with primary interest in the role of NSAIDs and cardiovascular risk. The literature review was conducted in PubMed search engines like Tripdatabase and with certain keywords. Of the 15 original papers found, 9 did not correspond completely to the central focus, so the approach was decided from 6 original articles from the past 5 years, which address the central focus of increased cardiovascular risk found (fatal and non-fatal events) in patients with prior cardiovascular disease or AMI being prescribed NSAIDs for any reason. The risk of fatal/non-fatal events in each of the studies is expressed by the odds ratio (OR)/hazard ratio (HR), defined as the probability of an event occurring. A moderate risk was observed for ibuprofen. It increases the risk of acute coronary syndrome after 5 years of cardiovascular event, especially in the 2nd year (OR 1.63; 95% CI 1.42-1.87). It also increases the risk of stroke (HR 1.23; 95% IC 1.10-1.38). Cyclo-oxygenase-2 inhibitors were the third risk group, after nabumetone and diclofenac. Celecoxib increases risk from the 14th day of treatment (HR 2.3; 95% CI 1.79-3.02), having an OR

  13. Safe and unsafe spaces: Non-fatal overdose, arrest, and receptive syringe sharing among people who inject drugs in public and semi-public spaces in Baltimore City.

    Science.gov (United States)

    Hunter, Kyle; Park, Ju Nyeong; Allen, Sean T; Chaulk, Patrick; Frost, Taeko; Weir, Brian W; Sherman, Susan G

    2018-04-13

    The spaces in which drug use occurs constitutes a key aspect of the "risk environment" of people who inject drugs (PWID). We aimed to add nuance to the characterization of "safe" and "unsafe" spaces in PWID's environments to further understand how these spaces amplify the risk of morbidities associated with injection drug use. PWID were recruited through the Baltimore City syringe service program and through peer referral. Participants completed a socio-behavioral survey. Multivariable logistic regression was used to identify associations between utilization of public, semi-public and private spaces with arrest, non-fatal overdose, and receptive syringe sharing. The sample of PWID (N = 283) was mostly 45 years and older (54%), male (69%), Black (55%), and heroin users (96%). Compared to PWID who primarily used private settings, the adjusted odds of recent overdose were greater among PWID who mostly used semi-public and public locations to inject drugs. We also found independent associations between arrest and semi-public spaces, and between receptive syringe sharing and public spaces (all p spaces where PWID can reduce their risk of overdose, likelihood of arrest and blood-borne diseases, and the dual potential of the environment in promoting health and risk. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. The Economic Cost of Suicide and Non-Fatal Suicide Behavior in the Australian Workforce and the Potential Impact of a Workplace Suicide Prevention Strategy

    Directory of Open Access Journals (Sweden)

    Irina Kinchin

    2017-03-01

    Full Text Available Suicide and non-fatal suicide behavior (NFSB are significant problems faced by most countries. The objective of this research is to quantify the economic cost of suicide and NFSB in the Australian workforce and to examine the potential impact of introducing a workplace suicide prevention intervention to reduce this burden. The analysis used the best available suicide data, a well-established costing methodology, and a proven workplace intervention. In 2014, 903 workers died by suicide, 2303 workers harmed themselves resulting in full incapacity, and 11,242 workers harmed themselves resulting in a short absence from work. The present value of the economic cost of suicide and NFSB is estimated at $6.73 billion. Our analysis suggests the economic benefit of implementing a universal workplace strategy would considerably outweigh the cost of the strategy. For every one dollar invested, the benefits would be in excess of $1.50 ($1.11–$3.07, representing a positive economic investment. All variations of the key parameter hold the positive benefit-cost ratio. Rates of suicide and NFSB are far too high in Australia and elsewhere. More needs to be done to reduce this burden. Although workplace strategies are appropriate for those employed, these interventions must be used within a multifaceted approach that reflects the complex nature of self-harming behavior.

  15. Recent Results from Beam Tests of 3D and Pad pCVD Diamond Detectors

    CERN Document Server

    Wallny, Rainer

    2017-01-01

    Results from prototypes of a detector using chemical vapor deposited (CVD) diamond with embedded resistive electrodes in the bulk forming a 3D diamond device are presented. A detector system consisting of 3D devices based on poly-crystalline CVD (pCVD) diamond was connected to a multi-channel readout and successfully tested in a 120 GeV/c proton beam at CERN proving for the first time the feasibility of the 3D detector concept in pCVD for particle tracking applications. We also present beam test results on the dependence of signal size on incident particle rate in charged particle detectors based on poly-crystalline CVD diamond. The detectors were tested in a 260 MeV/c pion beam over a range of particle fluxes from 2 kHz/cm2 to 10 MHz/cm2 . The pulse height of the sensors was measured with pad readout electronics at a peaking time of 7 ns. Our data from the 2015 beam tests at PSI indicate that the pulse height of poly-crystalline CVD diamond sensor irradiated to 5×1014 neq/cm2 is independent of particle flux...

  16. Validation of a model to investigate the effects of modifying cardiovascular disease (CVD risk factors on the burden of CVD: the rotterdam ischemic heart disease and stroke computer simulation (RISC model

    Directory of Open Access Journals (Sweden)

    van Kempen Bob JH

    2012-12-01

    Full Text Available Abstract Background We developed a Monte Carlo Markov model designed to investigate the effects of modifying cardiovascular disease (CVD risk factors on the burden of CVD. Internal, predictive, and external validity of the model have not yet been established. Methods The Rotterdam Ischemic Heart Disease and Stroke Computer Simulation (RISC model was developed using data covering 5 years of follow-up from the Rotterdam Study. To prove 1 internal and 2 predictive validity, the incidences of coronary heart disease (CHD, stroke, CVD death, and non-CVD death simulated by the model over a 13-year period were compared with those recorded for 3,478 participants in the Rotterdam Study with at least 13 years of follow-up. 3 External validity was verified using 10 years of follow-up data from the European Prospective Investigation of Cancer (EPIC-Norfolk study of 25,492 participants, for whom CVD and non-CVD mortality was compared. Results At year 5, the observed incidences (with simulated incidences in brackets of CHD, stroke, and CVD and non-CVD mortality for the 3,478 Rotterdam Study participants were 5.30% (4.68%, 3.60% (3.23%, 4.70% (4.80%, and 7.50% (7.96%, respectively. At year 13, these percentages were 10.60% (10.91%, 9.90% (9.13%, 14.20% (15.12%, and 24.30% (23.42%. After recalibrating the model for the EPIC-Norfolk population, the 10-year observed (simulated incidences of CVD and non-CVD mortality were 3.70% (4.95% and 6.50% (6.29%. All observed incidences fell well within the 95% credibility intervals of the simulated incidences. Conclusions We have confirmed the internal, predictive, and external validity of the RISC model. These findings provide a basis for analyzing the effects of modifying cardiovascular disease risk factors on the burden of CVD with the RISC model.

  17. Defining the relationship between COPD and CVD: what are the implications for clinical practice?

    Science.gov (United States)

    Morgan, Ann D; Zakeri, Rosita; Quint, Jennifer K

    2018-01-01

    Cardiovascular diseases (CVDs) are arguably the most important comorbidities in chronic obstructive pulmonary disease (COPD). CVDs are common in people with COPD, and their presence is associated with increased risk for hospitalization, longer length of stay and all-cause and CVD-related mortality. The economic burden associated with CVD in this population is considerable and the cumulative cost of treating comorbidities may even exceed that of treating COPD itself. Our understanding of the biological mechanisms that link COPD and various forms of CVD has improved significantly over the past decade. But despite broad acceptance of the prognostic significance of CVDs in COPD, there remains widespread under-recognition and undertreatment of comorbid CVD in this population. The reasons for this are unclear; however institutional barriers and a lack of evidence-based guidelines for the management of CVD in people with COPD may be contributory factors. In this review, we summarize current knowledge relating to the prevalence and incidence of CVD in people with COPD and the mechanisms that underlie their coexistence. We discuss the implications for clinical practice and highlight opportunities for improved prevention and treatment of CVD in people with COPD. While we advocate more active assessment for signs of cardiovascular conditions across all age groups and all stages of COPD severity, we suggest targeting those aged under 65 years. Evidence indicates that the increased risks for CVD are particularly pronounced in COPD patients in mid-to-late-middle-age and thus it is in this age group that the benefits of early intervention may prove to be the most effective. PMID:29355081

  18. Risk of non-fatal suicide ideation and behaviour in recent onset schizophrenia--the influence of clinical, social, self-esteem and demographic factors.

    Science.gov (United States)

    Tarrier, Nicholas; Barrowclough, Christine; Andrews, Bernice; Gregg, Lynsey

    2004-11-01

    Suicide rates amongst schizophrenic patients are high. There are disadvantages in investigating successfully completed suicides which make suicidal ideation and previous attempts important proxy measures of suicidal risk. The aim of this study was to investigate factors associated with these risk measures. Fifty-nine patients suffering recent onset schizophrenia were assessed for suicidal ideation and history, and a range of demographic, clinical, social (including relatives' Expressed Emotion) and self-esteem measures. Univariate comparisons were made between those with and without suicide ideation and previous attempts. Path analysis was conducted to identify factors directly or indirectly associated with a composite scale of risk (low, medium or high). Approximately 25% of the sample reported a current desire to kill themselves and 47% had made one or more previous attempts. There were numerous significant univariate differences between those with or without ideation or history. Path analysis indicated that greater hopelessness (OR 1.22) and longer duration of illness (OR 1.13) increased risk. Hopelessness was associated with higher negative self-evaluation and social isolation. Negative self-evaluation was associated with more relatives' criticism which was associated with more negative symptoms. Being a male, unmarried and unemployed were all significantly associated with an increase in negative symptoms. Social isolation was associated with being unemployed, older, more positive symptoms and longer illness duration. Duration of illness was not itself predicted by any other variables. Non-fatal suicide ideation and behaviour are significantly associated with an array of demographic, clinical, interpersonal and psychological factors. To reduce risk of suicide, these factors need to be assessed and methods developed to reduce their influence.

  19. Association between mediterranean diet and non-fatal cardiovascular events, in the context of anxiety and depression disorders: a case/case-control study.

    Science.gov (United States)

    Georgousopoulou, Ekavi N; Kastorini, Christina-Maria; Milionis, Haralampos J; Ntziou, Evangelia; Kostapanos, Michael S; Nikolaou, Vassilios; Vemmos, Konstantinos N; Goudevenos, John A; Panagiotakos, Demosthenes B

    2014-01-01

    The aim of this study was to investigate the effect of the Mediterranean diet on the likelihood of having a non-fatal cardiovascular outcome, taking into account anxiety and depression status. This was a case-control study with individual matching by age and sex. During 2009-2010, 1000 participants were enrolled; 250 were consecutive patients with a first acute coronary syndrome (ACS), 250 were consecutive patients with a first ischemic stroke, and 500 were population-based control subjects, one-for-one matched to the patients by age and sex. Among other characteristics, adherence to the Mediterranean diet was assessed by the MedDietScore, anxiety was assessed with the Spielberger State-Trait Anxiety Inventory form Y-2, while depressive symptomatology was evaluated by the Zung Depression Rating Scale. Higher adherence to the Mediterranean diet was associated with a lower likelihood of ACS and ischemic stroke, even after adjusting for anxiety or depression (ACS: OR=0.92, 95%CI 0.87-0.98 and 0.93, 0.88-0.98, respectively; ischemic stroke: 0.91, 0.84-0.98 and 0.90, 0.83-0.97, respectively). For both ACS and stroke patients, anxiety and depression were associated with a higher likelihood of ACS and stroke. When stratifying for depression or anxiety status, the Mediterranean diet remained a significantly protective factor only for people with low levels of depression and anxiety for ACS, and only for people with low levels of anxiety, as far as stroke was concerned. Anxiety and depression seem to play a mediating role in the protective relationship between adherence to the Mediterranean diet and the likelihood of developing cardiovascular events.

  20. MgO by injection CVD

    International Nuclear Information System (INIS)

    Abrutis, A.; Kubilius, V.; Teiserkis, A.; Bigelyte, V.; Vengalis, B.; Jukna, A.; Butkute, R.

    1997-01-01

    Epitaxial YBa 2 Cu 3 O 7 layers with 45 in-plane orientation have been grown by injection CVD on MgO substrates polished off-axis to within 1.4-1.9 of the [100] direction. This new single-source CVD process is based on computer-controlled injection of precise microdoses of a metal-organic precursor solution into a CVD reactor. A wide range of solution compositions was tested to investigate compositional effects on phase purity, surface morphology, texturing and superconducting properties of the prepared films. The highest quality films with pure 45 texture had a smooth surface, zero resistance T c (R=0) of 88-89 K, and critical current density J c (77 K) above 10 6 A/cm 2 . (orig.) and critical current density J c (77 K) above 10 6 A/cm 2 . (orig.)

  1. CVD mechanism of pyrolytic boron nitride

    International Nuclear Information System (INIS)

    Tanji, H.; Monden, K.; Ide, M.

    1987-01-01

    Pyrolytic boron nitride (P-BN) has become a essential material for III-V compound semiconductor manufacturing process. As the demand from electronics industry for larger single crystals increases, the demand for larger and more economical P-BN components is growing rapidly. P-BN is manufactured by low pressure CVD using boron-trihalides and ammonia as the reactants. In spite that P-BN has been in the market for quite a long time, limited number of fundamental studies regarding the kinetics and the formation mechanism of P-BN have been reported. As it has been demonstrated in CVD of Si, knowledge and both theoretical and empirical modeling of CVD process can be applied to improve the deposition technology and to give more uniform deposition with higher efficiency, and it should also apply to the deposition of P-BN

  2. High plasma cholesteryl ester transfer protein levels may favour reduced incidence of cardiovascular events in men with low triglycerides

    NARCIS (Netherlands)

    Borggreve, Susanna E.; Hillege, Hans L.; Dallinga-Thie, Geesje M.; de Jong, Paul E.; Wolffenbuttel, Bruce H. R.; Grobbee, Diederik E.; van Tol, Arie; Dullaart, Robin P. F.

    2007-01-01

    High cholesteryl ester transfer protein (CETP) concentrations are associated with increased risk of cardiovascular disease (CVD) in subjects with high triglycerides. We determined the relationship of plasma CETP with incident CVD in a population with relatively low triglycerides. A nested

  3. Recent results on CVD diamond radiation sensors

    Science.gov (United States)

    Weilhammer, P.; Adam, W.; Bauer, C.; Berdermann, E.; Bogani, F.; Borchi, E.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; v. d. Eijk, R.; van Eijk, B.; Fallou, A.; Fish, D.; Fried, M.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Knopfle, K. T.; Krammer, M.; Manfredi, P. F.; Meier, D.; LeNormand; Pan, L. S.; Pernegger, H.; Pernicka, M.; Plano, R.; Re, V.; Riester, J. L.; Roe, S.; Roff; Rudge, A.; Schieber, M.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R. J.; Tesarek, R.; Thomson, G. B.; Trawick, M.; Trischuk, W.; Turchetta, R.; RD 42 Collaboration

    1998-02-01

    CVD diamond radiation sensors are being developed for possible use in trackers in the LHC experiments. The diamond promises to be radiation hard well beyond particle fluences that can be tolerated by Si sensors. Recent results from the RD 42 collaboration on charge collection distance and on radiation hardness of CVD diamond samples will be reported. Measurements with diamond tracking devices, both strip detectors and pixel detectors, will be discussed. Results from beam tests using a diamond strip detector which was read out with fast, 25 ns shaping time, radiation-hard pipeline electronics will be presented.

  4. Low temperature CVD deposition of silicon carbide

    International Nuclear Information System (INIS)

    Dariel, M.; Yeheskel, J.; Agam, S.; Edelstein, D.; Lebovits, O.; Ron, Y.

    1991-04-01

    The coating of graphite on silicon carbide from the gaseous phase in a hot-well, open flow reactor at 1150degC is described. This study constitutes the first part of an investigation of the process for the coating of nuclear fuel by chemical vapor deposition (CVD)

  5. CVD diamond pixel detectors for LHC experiments

    CERN Document Server

    Wedenig, R; Bauer, C; Berdermann, E; Bergonzo, P; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Grigoriev, E; Hallewell, G D; Hall-Wilton, R; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Karl, C; Kass, R; Knöpfle, K T; Krammer, Manfred; Lo Giudice, A; Lü, R; Manfredi, P F; Manfredotti, C; Marshall, R D; Meier, D; Mishina, M; Oh, A; Pan, L S; Palmieri, V G; Pernicka, Manfred; Peitz, A; Pirollo, S; Polesello, P; Pretzl, Klaus P; Procario, M; Re, V; Riester, J L; Roe, S; Roff, D G; Rudge, A; Runólfsson, O; Russ, J; Schnetzer, S R; Sciortino, S; Speziali, V; Stelzer, H; Stone, R; Suter, B; Tapper, R J; Tesarek, R J; Trawick, M L; Trischuk, W; Vittone, E; Wagner, A; Walsh, A M; Weilhammer, Peter; White, C; Zeuner, W; Ziock, H J; Zöller, M

    1999-01-01

    This paper reviews the development of CVD diamond pixel detectors. The preparation of the diamond pixel sensors for bump-bonding to the pixel readout electronics for the LHC and the results from beam tests carried out at CERN are described. (9 refs).

  6. CVD diamond pixel detectors for LHC experiments

    Energy Technology Data Exchange (ETDEWEB)

    Wedenig, R.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knoepfle, K.T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P.F.; Manfredotti, C.; Marshall, R.D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L.S.; Palmieri, V.G.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Procario, M.; Re, V.; Riester, J.L.; Roe, S.; Roff, D.; Rudge, A.; Runolfsson, O.; Russ, J.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trawick, M.; Trischuk, W.; Vittone, E.; Wagner, A.; Walsh, A.M.; Weilhammer, P.; White, C.; Zeuner, W.; Ziock, H.; Zoeller, M.; Blanquart, L.; Breugnion, P.; Charles, E.; Ciocio, A.; Clemens, J.C.; Dao, K.; Einsweiler, K.; Fasching, D.; Fischer, P.; Joshi, A.; Keil, M.; Klasen, V.; Kleinfelder, S.; Laugier, D.; Meuser, S.; Milgrome, O.; Mouthuy, T.; Richardson, J.; Sinervo, P.; Treis, J.; Wermes, N

    1999-08-01

    This paper reviews the development of CVD diamond pixel detectors. The preparation of the diamond pixel sensors for bump-bonding to the pixel readout electronics for the LHC and the results from beam tests carried out at CERN are described.

  7. CVD diamond pixel detectors for LHC experiments

    International Nuclear Information System (INIS)

    Wedenig, R.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knoepfle, K.T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P.F.; Manfredotti, C.; Marshall, R.D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L.S.; Palmieri, V.G.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Procario, M.; Re, V.; Riester, J.L.; Roe, S.; Roff, D.; Rudge, A.; Runolfsson, O.; Russ, J.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trawick, M.; Trischuk, W.; Vittone, E.; Wagner, A.; Walsh, A.M.; Weilhammer, P.; White, C.; Zeuner, W.; Ziock, H.; Zoeller, M.; Blanquart, L.; Breugnion, P.; Charles, E.; Ciocio, A.; Clemens, J.C.; Dao, K.; Einsweiler, K.; Fasching, D.; Fischer, P.; Joshi, A.; Keil, M.; Klasen, V.; Kleinfelder, S.; Laugier, D.; Meuser, S.; Milgrome, O.; Mouthuy, T.; Richardson, J.; Sinervo, P.; Treis, J.; Wermes, N.

    1999-01-01

    This paper reviews the development of CVD diamond pixel detectors. The preparation of the diamond pixel sensors for bump-bonding to the pixel readout electronics for the LHC and the results from beam tests carried out at CERN are described

  8. Turbostratic stacked CVD graphene for high-performance devices

    Science.gov (United States)

    Uemura, Kohei; Ikuta, Takashi; Maehashi, Kenzo

    2018-03-01

    We have fabricated turbostratic stacked graphene with high-transport properties by the repeated transfer of CVD monolayer graphene. The turbostratic stacked CVD graphene exhibited higher carrier mobility and conductivity than CVD monolayer graphene. The electron mobility for the three-layer turbostratic stacked CVD graphene surpassed 10,000 cm2 V-1 s-1 at room temperature, which is five times greater than that for CVD monolayer graphene. The results indicate that the high performance is derived from maintenance of the linear band dispersion, suppression of the carrier scattering, and parallel conduction. Therefore, turbostratic stacked CVD graphene is a superior material for high-performance devices.

  9. What Can Influence Iranian Suicide Attempters to Go Through the Process of Non-Fatal Suicide Act Once Again? A Preliminary Report.

    Science.gov (United States)

    Toudehskchuie, Gholam Reza Ghassemi; Fereidoon, Mahsa

    2016-07-01

    The thrust of this study was to examine some of the psycho-social risk factors for the recurrence of non-fatal suicide attempt in a sample of 1121 inmates admitted between April 2012 to June 2013 at the toxicology emergency ward, Noor Medical Centre, Isfahan, Iran. Out of the total participants, 240 of them reported history of suicide attempt and assumed the status of case group. The remaining 881 patients were admitted first their attempt and constituted the control group. Cases were compared to the controls with respect to select demographic features (i.e. age, sex, education, occupation, marital status, type of residence, and locale), current suicide attempt method, family history of suicide and drug abuse, history of psychiatric disorder, physical ailment and physical disability, substance abuse and alcohol use, psychiatric diagnosis, and recent life hassles (i.e. interpersonal, occupational, financial, medical, and home affairs). We used a structured interview schedule to interview the participants. Psychiatric diagnosis was based on the DSM-IV criteria. Data were computer analyzed using SPSS.21 and administering statistical analysis including Chi Square, t-student, and logistic regression. Demographic risk factors for recurrence of suicide attempts at the univariate level included occupational status [Crud odds Ratio (COR) = 0.53] and type of residence (COR = 1.40). Medical and psychiatric risk factors at the univariate level included substance abuse (COR = 1.97), physical ailment (COR = 1.76), alcohol use (COR = 1.84), psychiatric disorder (COR = 3.69), and history of suicide in the family of origin (COR = 1.86). Recent life hassles risk factors at the univariate level included financial constraints (COR = 1.46) and medical emergencies (COR = 3.48). A multivariate logistic regression model identified five variables (i.e. substance abuse, alcohol use, psychiatric illness, suicide in family, and medical emergencies) that were statistically

  10. Incidence and predictors of cardiovascular events in a cohort of patients with rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Alice Morais Castro

    2016-07-01

    Full Text Available Introduction: An excess in cardiovascular (CV morbidity and mortality has been recognized in Rheumatoid Arthritis (RA patients when compared to the general population. Given the paucity of prospective data, our aim was to estimate the incidence of CV events and the contribution of traditional CVD risk factors and RA-related parameters to future events. Methods: Incident fatal and non-fatal CV events (hospitalizations due to unstable angina, myocardial infarction, coronary artery revascularization procedures, stroke, or CV death were assessed in a prospective cohort of RA women followed since 2007 and without CV events at cohort entry. The presence of traditional CV risk factors, disease characteristics, medication, carotid ultrasound, and biomarkers of inflammation and endothelial activation were evaluated at baseline. Univariate Cox proportional hazard models were used to identify risk factors for CV events. Results: Among 106 women followed over 565 patient-years we identified 4 CV events (1 fatal stroke, 2 myocardial infarction and 1 unstable angina, which contributed to an incidence rate of 7 per 1000 person-years (95%CI 2.0- 13.9. Patients who developed CV events were older, but the distribution of other traditional CV risk factors was otherwise similar in both groups. Also, corticosteroid dosage and proportion of patients with carotid atherosclerotic plaques was higher in those with CV events. Erythrocyte sedimentation rate (ESR (HR 1.036; 95%CI 1.005-1.067 and soluble intercellular adhesion molecule-1 (sICAM-1 serum levels (HR 1.002; 95%CI 1.000-1.003 significantly contributed to CV events. These results remained significant after adjusting for patients’ age. Conclusion: We found an incidence of cardiovascular events in women with RA of 7 per 1000 patent-years. This value is similar to that found in other Portuguese cohort of RA patients1 and much higher than the incidence reported for the general Portuguese population. Markers of

  11. Chemical Vapor-Deposited (CVD) Diamond Films for Electronic Applications

    Science.gov (United States)

    1995-01-01

    Diamond films have a variety of useful applications as electron emitters in devices such as magnetrons, electron multipliers, displays, and sensors. Secondary electron emission is the effect in which electrons are emitted from the near surface of a material because of energetic incident electrons. The total secondary yield coefficient, which is the ratio of the number of secondary electrons to the number of incident electrons, generally ranges from 2 to 4 for most materials used in such applications. It was discovered recently at the NASA Lewis Research Center that chemical vapor-deposited (CVD) diamond films have very high secondary electron yields, particularly when they are coated with thin layers of CsI. For CsI-coated diamond films, the total secondary yield coefficient can exceed 60. In addition, diamond films exhibit field emission at fields orders of magnitude lower than for existing state-of-the-art emitters. Present state-of-the-art microfabricated field emitters generally require applied fields above 5x10^7 V/cm. Research on field emission from CVD diamond and high-pressure, high-temperature diamond has shown that field emission can be obtained at fields as low as 2x10^4 V/cm. It has also been shown that thin layers of metals, such as gold, and of alkali halides, such as CsI, can significantly increase field emission and stability. Emitters with nanometer-scale lithography will be able to obtain high-current densities with voltages on the order of only 10 to 15 V.

  12. CVD calibration light systems specifications. Rev. 0

    International Nuclear Information System (INIS)

    Mcllwain, A. K.

    1992-04-01

    Two prototype Cerenkov Viewing Device Calibration Light systems for the Mark IV CVD have been fabricated. They consist of a maintenance unit that will be used by the IAEA maintenance staff and a field unit that will be used by IAEA inspectors. More detailed information on the design of the calibration units can be obtained from the document SSP-39 and additional information on the Mark IV CVD can be obtained from the operating manual published as Canadian Safeguards Support Program document CSSP 6. The specifications refer to the prototype units which will be demonstrated to the IAEA in 1992 May. Based upon the feedback from the IAEA, the instruments will be changed in the final production models to provide devices that more closely satisfy the needs of the end users

  13. Recent results with CVD diamond trackers

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knoepfle, K.T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P.F.; Manfredotti, C.; Marshall, R.D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L.S.; Palmieri, V.G.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Procario, M.; Re, V.; Riester, J.L.; Roe, S.; Roff, D.; Rudge, A.; Runolfsson, O.; Russ, J.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trawick, M.; Trischuk, W.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; White, C.; Ziock, H.; Zoeller, M

    1999-08-01

    We present recent results on the use of Chemical Vapor Deposition (CVD) diamond microstrip detectors for charged particle tracking. A series of detectors was fabricated using 1 x 1 cm{sup 2} diamonds. Good signal-to-noise ratios were observed using both slow and fast readout electronics. For slow readout electronics, 2 {mu}s shaping time, the most probable signal-to-noise ratio was 50 to 1. For fast readout electronics, 25 ns peaking time, the most probable signal-to-noise ratio was 7 to 1. Using the first 2 x 4 cm{sup 2} diamond from a production CVD reactor with slow readout electronics, the most probable signal-to-noise ratio was 23 to 1. The spatial resolution achieved for the detectors was consistent with the digital resolution expected from the detector pitch.

  14. Recent results with CVD diamond trackers

    CERN Document Server

    Adam, W; Berdermann, E; Bergonzo, P; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Grigoriev, E; Hallewell, G D; Hall-Wilton, R; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Karl, C; Kass, R; Knöpfle, K T; Krammer, Manfred; Lo Giudice, A; Lü, R; Manfredi, P F; Manfredotti, C; Marshall, R D; Meier, D; Mishina, M; Oh, A; Pan, L S; Palmieri, V G; Pernicka, Manfred; Peitz, A; Pirollo, S; Polesello, P; Pretzl, Klaus P; Procario, M; Re, V; Riester, J L; Roe, S; Roff, D G; Rudge, A; Runólfsson, O; Russ, J; Schnetzer, S R; Sciortino, S; Speziali, V; Stelzer, H; Stone, R; Suter, B; Tapper, R J; Tesarek, R J; Trawick, M L; Trischuk, W; Vittone, E; Walsh, A M; Wedenig, R; Weilhammer, Peter; White, C; Ziock, H J; Zöller, M

    1999-01-01

    We present recent results on the use of chemical vapor deposition (CVD) diamond microstrip detectors for charged particle tracking. A series of detectors was fabricated using 1*1 cm/sup 2/ diamonds. Good signal-to-noise ratios were observed using both slow and fast readout electronics. For slow readout electronics, 2 mu s shaping time, the most probable signal-to-noise ratio was 50 to 1. For fast readout electronics, 25 ns peaking time, the most probable signal-to-noise ratio was 7 to 1. Using the first 2*4 cm/sup 2/ diamond from a production CVD reactor with slow readout electronics, the most probable signal-to-noise ratio was 23 to 1. The spatial resolution achieved for the detectors was consistent with the digital resolution expected from the detector pitch. (6 refs).

  15. Ballistic Josephson junctions based on CVD graphene

    Science.gov (United States)

    Li, Tianyi; Gallop, John; Hao, Ling; Romans, Edward

    2018-04-01

    Josephson junctions with graphene as the weak link between superconductors have been intensely studied in recent years, with respect to both fundamental physics and potential applications. However, most of the previous work was based on mechanically exfoliated graphene, which is not compatible with wafer-scale production. To overcome this limitation, we have used graphene grown by chemical vapour deposition (CVD) as the weak link of Josephson junctions. We demonstrate that very short, wide CVD-graphene-based Josephson junctions with Nb electrodes can work without any undesirable hysteresis in their electrical characteristics from 1.5 K down to a base temperature of 320 mK, and their gate-tuneable critical current shows an ideal Fraunhofer-like interference pattern in a perpendicular magnetic field. Furthermore, for our shortest junctions (50 nm in length), we find that the normal state resistance oscillates with the gate voltage, consistent with the junctions being in the ballistic regime, a feature not previously observed in CVD-graphene-based Josephson junctions.

  16. Undoped CVD diamond films for electrochemical applications

    International Nuclear Information System (INIS)

    Mosinska, Lidia; Fabisiak, Kazimierz; Paprocki, Kazimierz; Kowalska, Magdalena; Popielarski, Pawel; Szybowicz, Miroslaw

    2013-01-01

    By using different deposition conditions, the CVD diamond films with different qualities and orientation were grown by the hot-filament CVD technique. The object of this article is to summarize and discuss relation between structural, physical and electrochemical properties of different diamond electrodes. The physical properties of the Hot Filament CVD microcrystalline diamond films are analyzed by scanning electron microscopy and Raman spectroscopy. In presented studies two different electrodes were used of the diamond grain sizes around 200 nm and 10 μm, as it was estimated from SEM picture. The diamond layers quality was checked on basis of FWHM (Full width at Half Maximum) of 1332 cm −1 diamond Raman peak. The ratio of sp 3 /sp 2 carbon bonds was determined by 1550 cm −1 G band and 1350 cm −1 D band in the Raman spectrum. The electrochemical properties were analyzed using (CV) cyclic voltammetry measurements in aqueous solutions. The sensitivity of undoped diamond electrodes depends strongly on diamond film quality and concentration of amorphous carbon phase in the diamond layer

  17. An assessment of radiotherapy dosimeters based on CVD grown diamond

    International Nuclear Information System (INIS)

    Ramkumar, S.; Buttar, C.M.; Conway, J.; Whitehead, A.J.; Sussman, R.S.; Hill, G.; Walker, S.

    2001-01-01

    Diamond is potentially a very suitable material for use as a dosimeter for radiotherapy. Its radiation hardness, the near tissue equivalence and chemical inertness are some of the characteristics of diamond, which make it well suited for its application as a dosimeter. Recent advances in the synthesis of diamond by chemical vapour deposition (CVD) technology have resulted in the improvement in the quality of material and increased its suitability for radiotherapy applications. We report in this paper, the response of prototype dosimeters based on two different types (CVD1 and CVD2) of CVD diamond to X-rays. The diamond devices were assessed for sensitivity, dependence of response on dose and dose rate, and compared with a Scanditronix silicon photon diode and a PTW natural diamond dosimeter. The diamond devices of CVD1 type showed an initial increase in response with dose, which saturates after ∼6 Gy. The diamond devices of CVD2 type had a response at low fields ( 1162.8 V/cm), the CVD2-type devices showed polarisation and dose-rate dependence. The sensitivity of the CVD diamond devices varied between 82 and 1300 nC/Gy depending upon the sample type and the applied voltage. The sensitivity of CVD diamond devices was significantly higher than that of natural diamond and silicon dosimeters. The results suggest that CVD diamond devices can be fabricated for successful use in radiotherapy applications

  18. Comparative evaluation of CVD diamond technologies

    Energy Technology Data Exchange (ETDEWEB)

    Anthony, T.R. [General Electric Corporate Research & Development Center, Schenectady, NY (United States)

    1993-01-01

    Chemical vapor deposition (CVD) of diamonds occurs from hydrogen-hydrocarbon gas mixtures in the presence of atomic hydrogen at subatmospheric pressures. Most CVD methods are based on different means of generating and transporting atomic hydrogen in a particular system. Evaluation of these different techniques involves their capital costs, material costs, energy costs, labor costs and the type and quality of diamond that they produce. Currently, there is no universal agreement on which is the best technique and technique selection has been largely driven by the professional background of the user as well as the particular application of interest. This article discusses the criteria for evaluating a process for low-pressure deposition of diamond. Next, a brief history of low-pressure diamond synthesis is reviewed. Several specific processes are addressed, including the hot filament process, hot filament electron-assisted chemical vapor deposition, and plasma generation of atomic hydrogen by glow discharge, microwave discharge, low pressure radio frequency discharge, high pressure DC discharge, high pressure microwave discharge jets, high pressure RF discharge, and high and low pressure flames. Other types of diamond deposition methods are also evaluated. 101 refs., 15 figs.

  19. Development of CVD diamond radiation detectors

    CERN Document Server

    Adam, W; Berdermann, E; Bogani, F; Borchi, E; Bruzzi, Mara; Colledani, C; Conway, J; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fisch, D; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Grigoriev, E A; Hallewell, G D; Hall-Wilton, R; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Kass, R; Knöpfle, K T; Krammer, Manfred; Manfredi, P F; Meier, D; Mishina, M; Le Normand, F; Pan, L S; Pernegger, H; Pernicka, Manfred; Pirollo, S; Re, V; Riester, J L; Roe, S; Roff, D G; Rudge, A; Schnetzer, S R; Sciortino, S; Speziali, V; Stelzer, H; Stone, R; Tapper, R J; Tesarek, R J; Thomson, G B; Trawick, M L; Trischuk, W; Turchetta, R; Walsh, A M; Wedenig, R; Weilhammer, Peter; Ziock, H J; Zoeller, M M

    1998-01-01

    Diamond is a nearly ideal material for detecting ionizing radiation. Its outstanding radiation hardness, fast charge collection and low leakage current allow a diamond detector to be used in high ra diation, high temperature and in aggressive chemical media. We have constructed charged particle detectors using high quality CVD diamond. Characterization of the diamond samples and various detect ors are presented in terms of collection distance, $d=\\mu E \\tau$, the average distance electron-hole pairs move apart under the influence of an electric field, where $\\mu$ is the sum of carrier mo bilities, $E$ is the applied electric field, and $\\tau$ is the mobility weighted carrier lifetime. Over the last two years the collection distance increased from $\\sim$ 75 $\\mu$m to over 200 $\\mu$ m. With this high quality CVD diamond a series of micro-strip and pixel particle detectors have been constructed. These devices were tested to determine their position resolution and signal to n oise performance. Diamond detectors w...

  20. TSC response of irradiated CVD diamond films

    CERN Document Server

    Borchi, E; Bucciolini, M; Guasti, A; Mazzocchi, S; Pirollo, S; Sciortino, S

    1999-01-01

    CVD diamond films have been irradiated with electrons, sup 6 sup 0 Co photons and protons in order to study the dose response to exposure to different particles and energies and to investigate linearity with dose. The Thermally Stimulated Current (TSC) has been studied as a function of the dose delivered to polymethilmetacrilate (PMMA) in the range from 1 to 12 Gy with 20 MeV electrons from a linear accelerator. The TSC spectrum has revealed the presence of two components with peak temperatures of about 470 and 520 K, corresponding to levels lying in the diamond band gap with activation energies of the order of 0.7 - 1 eV. After the subtraction of the exponential background the charge emitted during the heating scan has been evaluated and has been found to depend linearly on the dose. The thermally emitted charge of the CVD diamond films has also been studied using different particles. The samples have been irradiated with the same PMMA dose of about 2 Gy with 6 and 20 MeV electrons from a Linac, sup 6 sup 0 ...

  1. High collection efficiency CVD diamond alpha detectors

    International Nuclear Information System (INIS)

    Bergonzo, P.; Foulon, F.; Marshall, R.D.; Jany, C.; Brambilla, A.; McKeag, R.D.; Jackman, R.B.

    1998-01-01

    Advances in Chemical Vapor Deposited (CVD) diamond have enabled the routine use of this material for sensor device fabrication, allowing exploitation of its unique combination of physical properties (low temperature susceptibility (> 500 C), high resistance to radiation damage (> 100 Mrad) and to corrosive media). A consequence of CVD diamond growth on silicon is the formation of polycrystalline films which has a profound influence on the physical and electronic properties with respect to those measured on monocrystalline diamond. The authors report the optimization of physical and geometrical device parameters for radiation detection in the counting mode. Sandwich and co-planar electrode geometries are tested and their performances evaluated with regard to the nature of the field profile and drift distances inherent in such devices. The carrier drift length before trapping was measured under alpha particles and values as high as 40% of the overall film thickness are reported. Further, by optimizing the device geometry, they show that a gain in collection efficiency, defined as the induced charge divided by the deposited charge within the material, can be achieved even though lower bias values are used

  2. A CVD diamond beam telescope for charged particle tracking

    CERN Document Server

    Adam, W; Bergonzo, P; de Boer, Wim; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; D'Angelo, P; Dabrowski, W; Delpierre, P A; Dulinski, W; Doroshenko, J; Doucet, M; van Eijk, B; Fallou, A; Fischer, P; Fizzotti, F; Kania, D R; Gan, K K; Grigoriev, E; Hallewell, G D; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kaplon, J; Kass, R; Keil, M; Knöpfle, K T; Koeth, T W; Krammer, Manfred; Meuser, S; Lo Giudice, A; MacLynne, L; Manfredotti, C; Meier, D; Menichelli, D; Mishina, M; Moroni, L; Noomen, J; Oh, A; Pan, L S; Pernicka, Manfred; Perera, L P; Riester, J L; Roe, S; Rudge, A; Russ, J; Sala, S; Sampietro, M; Schnetzer, S; Sciortino, S; Stelzer, H; Stone, R; Suter, B; Trischuk, W; Tromson, D; Vittone, E; Weilhammer, Peter; Wermes, N; Wetstein, M; Zeuner, W; Zöller, M

    2002-01-01

    CVD diamond is a radiation hard sensor material which may be used for charged particle tracking near the interaction region in experiments at high luminosity colliders. The goal of the work described here is to investigate the use of several detector planes made of CVD diamond strip sensors for charged particle tracking. Towards this end a tracking telescope composed entirely of CVD diamond planes has been constructed. The telescope was tested in muon beams and its tracking capability has been investigated.

  3. Experiment and equipment of depositing diamond films with CVD system

    International Nuclear Information System (INIS)

    Xie Erqing; Song Chang'an

    2002-01-01

    CVD (chemical vapor deposition) emerged in recent years is a new technique for thin film deposition, which play a key role in development of modern physics. It is important to predominate the principle and technology of CVD for studying modern physics. In this paper, a suit of CVD experimental equipment for teaching in college physics is presented, which has simple design and low cost. The good result was gained in past teaching practices

  4. Comprehensive metabolomic profiling and incident cardiovascular disease: a systematic review

    Science.gov (United States)

    Background: Metabolomics is a promising tool of cardiovascular biomarker discovery. We systematically reviewed the literature on comprehensive metabolomic profiling in association with incident cardiovascular disease (CVD). Methods and Results: We searched MEDLINE and EMBASE from inception to Janua...

  5. New developments in CVD diamond for detector applications

    Science.gov (United States)

    Adam, W.; Berdermann, E.; Bergonzo, P.; de Boer, W.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Dulinski, W.; Doroshenko, J.; van Eijk, B.; Fallou, A.; Fischer, P.; Fizzotti, F.; Furetta, C.; Gan, K. K.; Ghodbane, N.; Grigoriev, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kaplon, J.; Kass, R.; Keil, M.; Knoepfle, K. T.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Menichelli, D.; Meuser, S.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pernicka, M.; Perera, L.; Potenza, R.; Riester, J. L.; Roe, S.; Rudge, A.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Sutera, C.; Trischuk, W.; Tromson, D.; Tuve, C.; Vincenzo, B.; Weilhammer, P.; Wermes, N.; Wetstein, M.; Zeuner, W.; Zoeller, M.

    Chemical Vapor Deposition (CVD) diamond has been discussed extensively as an alternative sensor material for use very close to the interaction region of the LHC and other machines where extreme radiation conditions exist. During the last seven years the RD42 collaboration has developed diamond detectors and tested them with LHC electronics towards the end of creating a device usable by experiments. The most recent results of this work are presented. Recently, a new form of CVD diamond has been developed: single crystal CVD diamond which resolves many of the issues associated with poly-crystalline CVD material. The first tests of this material are also presented.

  6. New developments in CVD diamond for detector applications

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W. [HEPHY, Vienna (Austria); Berdermann, E. [GSI, Darmstadt (Germany); Bergonzo, P.; Brambilla, A. [LETI/DEIN/SPE/CEA Saclay (France); Boer, W. de [Universitaet Karlsruhe, Karlsruhe (Germany); Bogani, F. [LENS, Florence (Italy); Borchi, E.; Bruzzi, M. [University of Florence (Italy); Colledani, C.; Dulinski, W. [LEPSI, IN2P3/CNRS-ULP, Strasbourg (France); Conway, J.; Doroshenko, J. [Rutgers University, Piscataway (United States); D' Angelo, P.; Furetta, C. [INFN, Milano (Italy); Dabrowski, W. [UMM, Cracow (Poland); Delpierre, P.; Fallou, A. [CPPM, Marseille (France); Eijk, B. van [NIKHEF, Amsterdam (Netherlands); Fischer, P. [Universitaet Bonn, Bonn (Germany); Fizzotti, F. [University of Torino (Italy); Gan, K.K.; Ghodbane, N.; Grigoriev, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kaplon, J.; Kass, R.; Keil, M.; Knoepfle, K.T.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Menichelli, D.; Meuser, S.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pernicka, M.; Perera, L.; Potenza, R.; Riester, J.L.; Roe, S.; Rudge, A.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Sutera, C.; Trischuk, W.; Tromson, D.; Tuve, C.; Vincenzo, B.; Weilhammer, P.; Wermes, N.; Wetstein, M.; Zeuner, W.; Zoeller, M.

    2004-07-01

    Chemical Vapor Deposition (CVD) diamond has been discussed extensively as an alternative sensor material for use very close to the interaction region of the LHC and other machines where extreme radiation conditions exist. During the last seven years the RD42 collaboration has developed diamond detectors and tested them with LHC electronics towards the end of creating a device usable by experiments. The most recent results of this work are presented. Recently, a new form of CVD diamond has been developed: single crystal CVD diamond which resolves many of the issues associated with poly-crystalline CVD material. The first tests of this material are also presented. (orig.)

  7. New developments in CVD diamond for detector applications

    International Nuclear Information System (INIS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Brambilla, A.; Boer, W. de; Bogani, F.; Borchi, E.; Bruzzi, M.; Colledani, C.; Dulinski, W.; Conway, J.; Doroshenko, J.; D'Angelo, P.; Furetta, C.; Dabrowski, W.; Delpierre, P.; Fallou, A.; Eijk, B. van; Fischer, P.; Fizzotti, F.; Gan, K.K.; Ghodbane, N.; Grigoriev, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kaplon, J.; Kass, R.; Keil, M.; Knoepfle, K.T.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Menichelli, D.; Meuser, S.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pernicka, M.; Perera, L.; Potenza, R.; Riester, J.L.; Roe, S.; Rudge, A.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Sutera, C.; Trischuk, W.; Tromson, D.; Tuve, C.; Vincenzo, B.; Weilhammer, P.; Wermes, N.; Wetstein, M.; Zeuner, W.; Zoeller, M.

    2004-01-01

    Chemical Vapor Deposition (CVD) diamond has been discussed extensively as an alternative sensor material for use very close to the interaction region of the LHC and other machines where extreme radiation conditions exist. During the last seven years the RD42 collaboration has developed diamond detectors and tested them with LHC electronics towards the end of creating a device usable by experiments. The most recent results of this work are presented. Recently, a new form of CVD diamond has been developed: single crystal CVD diamond which resolves many of the issues associated with poly-crystalline CVD material. The first tests of this material are also presented. (orig.)

  8. Application of CVD diamond film for radiation detection

    International Nuclear Information System (INIS)

    Zhou Haiyang; Zhu Xiaodong; Zhan Rujuan

    2005-01-01

    With the development of diamond synthesis at low pressure, the CVD diamond properties including electronic characteristics have improved continuously. Now the fabrication of electronic devices based on the CVD diamond has been one of hot research subjects in this field. Due to many unique advantages, such as high signal-noise ratio, fast time response, and normal output in extremely harsh surrounding, the CVD diamond radiation detector has attracted more and more interest. In this paper, we have reviewed the development and status of the CVD diamond radiation detector. The prospect of this detector is described. (authors)

  9. CVD diamond detectors for ionizing radiation

    CERN Document Server

    Friedl, M; Bauer, C; Berfermann, E; Bergonzo, P; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Gan, K K; Gheeraert, E; Grigoriev, E; Hallewell, G D; Hall-Wilton, R; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Karl, C; Kass, R; Knöpfle, K T; Krammer, Manfred; Lo Giudice, A; Lü, R; Manfredi, P F; Manfredotti, C; Marshall, R D; Meier, D; Mishina, M; Oh, A; Pan, L S; Palmieri, V G; Pernegger, H; Pernicka, Manfred; Peitz, A; Pirollo, S; Polesello, P; Pretzl, Klaus P; Re, V; Riester, J L; Roe, S; Roff, D G; Rudge, A; Schnetzer, S R; Sciortino, S; Speziali, V; Stelzer, H; Stone, R; Tapper, R J; Tesarek, R J; Thomson, G B; Trawick, M L; Trischuk, W; Vittone, E; Walsh, A M; Wedenig, R; Weilhammer, Peter; Ziock, H J; Zöller, M

    1999-01-01

    In future HEP accelerators, such as the LHC (CERN), detectors and electronics in the vertex region of the experiments will suffer from extreme radiation. Thus radiation hardness is required for both detectors and electronics to survive in this harsh environment. CVD diamond, which is investigated by the RD42 Collaboration at CERN, can meet these requirements. Samples of up to 2*4 cm/sup 2/ have been grown and refined for better charge collection properties, which are measured with a beta source or in a test beam. A large number of diamond samples has been irradiated with hadrons to fluences of up to 5*10/sup 15/ cm/sup -2/ to study the effects of radiation. Both strip and pixel detectors were prepared in various geometries. Samples with strip metallization have been tested with both slow and fast readout electronics, and the first diamond pixel detector proved fully functional with LHC electronics. (16 refs).

  10. CVD diamond sensors for charged particle detection

    CERN Document Server

    Krammer, Manfred; Berdermann, E; Bergonzo, P; Bertuccio, G; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; D'Angelo, P; Dabrowski, W; Delpierre, P A; Dencuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Hallewell, G D; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Kass, R; Koeth, T W; Lo Giudice, A; Lü, R; MacLynne, L; Manfredotti, C; Meier, D; Mishina, M; Moroni, L; Oh, A; Pan, L S; Pernicka, Manfred; Peitz, A; Perera, L P; Pirollo, S; Procario, M; Riester, J L; Roe, S; Rousseau, L; Rudge, A; Russ, J; Sala, S; Sampietro, M; Schnetzer, S; Sciortino, S; Stelzer, H; Stone, R; Suter, B; Tapper, R J; Tesarek, R; Trischuk, W; Tromson, D; Vittone, E; Walsh, A M; Wedenig, R; Weilhammer, Peter; Wetstein, M; White, C; Zeuner, W; Zöller, M

    2001-01-01

    CVD diamond material was used to build position-sensitive detectors for single-charged particles to be employed in high-intensity physics experiments. To obtain position information, metal contacts shaped as strips or pixels are applied to the detector surface for one- or two- dimensional coordinate measurement. Strip detectors 2*4 cm/sup 2/ in size with a strip distance of 50 mu m were tested. Pixel detectors of various pixel sizes were bump bonded to electronics chips and investigated. A key issue for the use of these sensors in high intensity experiments is the radiation hardness. Several irradiation experiments were carried out with pions, protons and neutrons exceeding a fluence of 10/sup 15/ particles/cm/sup 2/. The paper presents an overview of the results obtained with strip and pixel detectors in high-energy test beams and summarises the irradiation studies. (8 refs).

  11. CVD diamond detectors for ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Friedl, M. E-mail: markus.friedl@cern.ch; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knoepfle, K.T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P.F.; Manfredotti, C.; Marshall, R.D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L.S.; Palmieri, V.G.; Pernegger, H.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Re, V.; Riester, J.L.; Roe, S.; Roff, D.; Rudge, A.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R.J.; Tesarek, R.; Thomson, G.B.; Trawick, M.; Trischuk, W.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Ziock, H.; Zoeller, M

    1999-10-01

    In future HEP accelerators, such as the LHC (CERN), detectors and electronics in the vertex region of the experiments will suffer from extreme radiation. Thus radiation hardness is required for both detectors and electronics to survive in this harsh environment. CVD diamond, which is investigated by the RD42 Collaboration at CERN, can meet these requirements. Samples of up to 2x4 cm{sup 2} have been grown and refined for better charge collection properties, which are measured with a {beta} source or in a test beam. A large number of diamond samples has been irradiated with hadrons to fluences of up to 5x10{sup 15} cm{sup -2} to study the effects of radiation. Both strip and pixel detectors were prepared in various geometries. Samples with strip metallization have been tested with both slow and fast readout electronics, and the first diamond pixel detector proved fully functional with LHC electronics. (author)

  12. CVD diamond detectors for ionizing radiation

    Science.gov (United States)

    Friedl, M.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knöpfle, K. T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P. F.; Manfredotti, C.; Marshall, R. D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L. S.; Palmieri, V. G.; Pernegger, H.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Re, V.; Riester, J. L.; Roe, S.; Roff, D.; Rudge, A.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R. J.; Tesarek, R.; Thomson, G. B.; Trawick, M.; Trischuk, W.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Ziock, H.; Zoeller, M.; RD42 Collaboration

    1999-10-01

    In future HEP accelerators, such as the LHC (CERN), detectors and electronics in the vertex region of the experiments will suffer from extreme radiation. Thus radiation hardness is required for both detectors and electronics to survive in this harsh environment. CVD diamond, which is investigated by the RD42 Collaboration at CERN, can meet these requirements. Samples of up to 2×4 cm2 have been grown and refined for better charge collection properties, which are measured with a β source or in a testbeam. A large number of diamond samples has been irradiated with hadrons to fluences of up to 5×10 15 cm-2 to study the effects of radiation. Both strip and pixel detectors were prepared in various geometries. Samples with strip metallization have been tested with both slow and fast readout electronics, and the first diamond pixel detector proved fully functional with LHC electronics.

  13. Premature menopause linked to CVD and osteoporosis.

    Science.gov (United States)

    Park, Claire; Overton, Caroline

    2010-03-01

    Premature menopause affects 1% of women under the age of 40, the usual age of the menopause is 51. Most women will present with irregular periods or no periods at all with or without climacteric symptoms. Around 10% of women present with primary amenorrhoea. A careful history and examination are required. It is important to ask specifically about previous chemotherapy or radiotherapy and to look for signs of androgen excess e.g. polycystic ovarian syndrome, adrenal problems e.g. galactorrhoea and thyroid goitres. Once pregnancy has been excluded, a progestagen challenge test can be performed in primary care. Norethisterone 5 mg tds po for ten days or alternatively medroxyprogesterone acetate 10 mg daily for ten days is prescribed. A withdrawal bleed within a few days of stopping the norethisterone indicates the presence of oestrogen and bleeding more than a few drops is considered a positive withdrawal bleed. The absence of a bleed indicates low levels of oestrogen, putting the woman at risk of CVD and osteoporosis. FSH levels above 30 IU/l are an indicator that the ovaries are failing and the menopause is approaching or has occurred. It should be remembered that FSH levels fluctuate during the month and from one month to the next, so a minimum of two measurements should be made at least four to six weeks apart. The presence of a bleed should not exclude premature menopause as part of the differential diagnosis as there can be varying and unpredictable ovarian function remaining. The progestagen challenge test should not be used alone, but in conjunction with FSH, LH and oestradiol. There is no treatment for premature menopause. Women desiring pregnancy should be referred to a fertility clinic and discussion of egg donation. Women not wishing to become pregnant should be prescribed HRT until the age of 50 to control symptoms of oestrogen deficiency and reduce the risks of osteoporosis and CVD.

  14. Cardiovascular disease incidence in adolescent and young adult cancer survivors: a retrospective cohort study.

    Science.gov (United States)

    Keegan, Theresa H M; Kushi, Lawrence H; Li, Qian; Brunson, Ann; Chawla, X; Chew, Helen K; Malogolowkin, Marcio; Wun, Ted

    2018-06-01

    Few population-based studies have focused on cardiovascular disease (CVD) risk in adolescent and young adult (AYA; 15-39 years) cancer survivors and none have considered whether CVD risk differs by sociodemographic factors. Analyses focused on 79,176 AYA patients diagnosed with 14 first primary cancers in 1996-2012 and surviving > 2 years after diagnosis with follow-up through 2014. Data were obtained from the California Cancer Registry and State hospital discharge data. CVD included coronary artery disease, heart failure, and stroke. The cumulative incidence of developing CVD accounted for the competing risk of death. Multivariable Cox proportional hazards regression evaluated factors associated with CVD and the impact of CVD on mortality. Overall, 2249 (2.8%) patients developed CVD. Survivors of central nervous system cancer (7.3%), acute lymphoid leukemia (6.9%), acute myeloid leukemia (6.8%), and non-Hodgkin lymphoma (4.1%) had the highest 10-year CVD incidence. In multivariable models, African-Americans (hazard ratio (HR) = 1.55, 95% confidence interval (CI) = 1.33-1.81; versus non-Hispanic Whites), those with public/no health insurance (HR = 1.78, 95% CI = 1.61-1.96; versus private) and those who resided in lower socioeconomic status neighborhoods had a higher CVD risk. These sociodemographic differences in CVD incidence were apparent across most cancer sites. The risk of death was increased by eightfold or higher among AYAs who developed CVD. While cancer therapies are known to increase the risk of CVD, this study additionally shows that CVD risk varies by sociodemographic factors. The identification and mitigation of CVD risk factors in these subgroups may improve long-term patient outcomes.

  15. Variations of CHI3L1, levels of the encoded glycoprotein YKL-40 and prediction of fatal and non-fatal ischemic stroke

    DEFF Research Database (Denmark)

    Rathcke, Camilla Noelle; Thomsen, Stine Brinkloev; Linneberg, Allan

    2012-01-01

    BACKGROUND: Polymorphisms of CHI3L1 are associated with inter-individual YKL-40 levels and YKL-40 is associated with an increased mortality and is elevated in patients with cardiovascular disease. We investigated the association between single nucleotide polymorphisms (SNPs) of CHI3L1, serum YKL-40...... levels and all-cause and cardiovascular mortality and first-time incidence of myocardial infarction, ischemic heart disease (IHD) and stroke. METHODOLOGY/PRINCIPAL FINDINGS: 12 SNPs of CHI3L1 were genotyped and serum YKL-40 was measured in 2656 Danes representative of the general population. Median...

  16. Diamond radiation detectors II. CVD diamond development for radiation detectors

    International Nuclear Information System (INIS)

    Kania, D.R.

    1997-01-01

    Interest in radiation detectors has supplied some of the impetus for improving the electronic properties of CVD diamond. In the present discussion, we will restrict our attention to polycrystalhne CVD material. We will focus on the evolution of these materials over the past decade and the correlation of detector performance with other properties of the material

  17. Lipids, atherosclerosis and CVD risk: is CRP an innocent bystander?

    DEFF Research Database (Denmark)

    Nordestgaard, B G; Zacho, J

    2009-01-01

    AIM: To evaluate recent human studies with respect to the interpretation of whether elevated plasma levels of C-reactive protein (CRP) cause cardiovascular disease (CVD), or whether elevated CRP levels more likely is an innocent bystander. DATA SYNTHESIS: Elevated CRP concentrations...... and vulnerability of atherosclerotic plaques, and thus simply an innocent bystander in CVD....

  18. Micro-strip sensors based on CVD diamond

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D' Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D. E-mail: dirk.meier@cern.ch; Mishina, M.; Moroni, L.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M

    2000-10-11

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  19. Micro-strip sensors based on CVD Diamond

    CERN Document Server

    Adam, W; Bergonzo, P; Bertuccio, G; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; D'Angelo, P; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Hallewell, G D; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Kass, R; Koeth, T W; Krammer, Manfred; Lo Giudice, A; Lü, R; MacLynne, L; Manfredotti, C; Meier, D; Mishina, M; Moroni, L; Oh, A; Pan, L S; Pernicka, Manfred; Peitz, A; Perera, L P; Pirollo, S; Procario, M; Riester, J L; Roe, S; Rousseau, L; Rudge, A; Russ, J; Sala, S; Sampietro, M; Schnetzer, S R; Sciortino, S; Stelzer, H; Stone, R; Suter, B; Tapper, R J; Tesarek, R J; Trischuk, W; Tromson, D; Vittone, E; Walsh, A M; Wedenig, R; Weilhammer, Peter; Wetstein, M; White, C; Zeuner, W; Zoeller, M M

    2000-01-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  20. Micro-strip sensors based on CVD diamond

    International Nuclear Information System (INIS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.

    2000-01-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation

  1. Micro-strip sensors based on CVD diamond

    Science.gov (United States)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; RD42 Collaboration

    2000-10-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  2. Depressive symptomatology in relation to 10-year (2004-2014) acute coronary syndrome incidence; the moderating role of diet and financial status.

    Science.gov (United States)

    Notara, Venetia; Panagiotakos, Demosthenes B; Tsompanaki, Elena; Kouvari, Matina; Kogias, Yannis; Papanagnou, George; Antonoulas, Antonis; Stravopodis, Petros; Zombolos, Spyros; Stergiouli, Ifigenia; Mantas, Yannis; Babatsikou, Fotoula; Pitsavos, Christos

    2016-05-01

    The association between depression status and 10-year cardiovascular disease (CVD) incidence among acute coronary syndrome (ACS) patients, in relation to nutritional and financial status, was evaluated. From October 2003 to September 2004, a sample of 2172 consecutive ACS patients from 6 Greek hospitals was enrolled. In 2013-14, the 10-year follow-up was performed. Depressive symptoms were evaluated using the validated CES-D score (range 0-60). Adherence to Mediterranean diet was assessed through MedDietScore (range 0-55) and financial status was determined by the annual income. Ranking from the 1st to 3rd CES-D tertile, recurrent fatal/non fatal ACS rates were 33%, 37% and 42%, respectively (p=0.006). Multiple logistic regression models revealed an adverse association of severe depression status (i.e. 3rd tertile) compared to no depression (i.e. 1st tertile) [odds ratio (OR)=1.31, 95% confidence interval (95% CI) 1.01, 1.69]. When controlling for financial status, the relationship between depression and ACS prognosis remained marginally significant; while subgroup analysis revealed that only patients with low/moderate income were negatively affected [OR=1.36, 95% CI 0.98, 1.88]. Further stratified analysis, by MedDietScore group, was applied; the above association remained significant only in patients with low compliance to this dietary pattern [OR=1.68, 95% CI 1.10, 2.18]. ACS coexisting with severe depression status seems to result in adverse disease outcomes while financial status and Mediterranean diet are proposed as potential moderators. Public health programs should focus on vulnerable groups and minimize depressive symptoms through appropriate medical treatment and lifestyle interventions, so as to ameliorate the disease prognosis in clinical and community levels. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Density of calcium in the ascending thoracic aorta and risk of incident cardiovascular disease events.

    Science.gov (United States)

    Thomas, Isac C; McClelland, Robyn L; Michos, Erin D; Allison, Matthew A; Forbang, Nketi I; Longstreth, W T; Post, Wendy S; Wong, Nathan D; Budoff, Matthew J; Criqui, Michael H

    2017-10-01

    The volume and density of coronary artery calcium (CAC) both independently predict cardiovascular disease (CVD) beyond standard risk factors, with CAC density inversely associated with incident CVD after accounting for CAC volume. We tested the hypothesis that ascending thoracic aorta calcium (ATAC) volume and density predict incident CVD events independently of CAC. The Multi-Ethnic Study of Atherosclerosis (MESA) is a prospective cohort study of participants without clinical CVD at baseline. ATAC and CAC were measured from baseline cardiac computed tomography (CT). Cox regression models were used to estimate the associations of ATAC volume and density with incident coronary heart disease (CHD) events and CVD events, after adjustment for standard CVD risk factors and CAC volume and density. Among 6811 participants, 234 (3.4%) had prevalent ATAC and 3395 (49.8%) had prevalent CAC. Over 10.3 years, 355 CHD and 562 CVD events occurred. One-standard deviation higher ATAC density was associated with a lower risk of CHD (HR 0.48 [95% CI 0.29-0.79], pdensity was inversely associated with incident CHD and CVD after adjustment for CVD risk factors and CAC volume and density. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Lifestyle factors and risk of cardiovascular diseases

    NARCIS (Netherlands)

    Hoevenaar-Blom, M.P.

    2013-01-01

    Background

    Evidence is accumulating that lifestyle factors influence the incidence of fatal and non-fatal cardiovascular diseases (CVD). A healthy diet, being physically active, moderate alcohol consumption and not smoking are associated with a lower CVD risk. In

  5. CVD carbon powders modified by ball milling

    Directory of Open Access Journals (Sweden)

    Kazmierczak Tomasz

    2015-09-01

    Full Text Available Carbon powders produced using a plasma assisted chemical vapor deposition (CVD methods are an interesting subject of research. One of the most interesting methods of synthesizing these powders is using radio frequency plasma. This method, originally used in deposition of carbon films containing different sp2/sp3 ratios, also makes possible to produce carbon structures in the form of powder. Results of research related to the mechanical modification of these powders have been presented. The powders were modified using a planetary ball mill with varying parameters, such as milling speed, time, ball/powder mass ratio and additional liquids. Changes in morphology and particle sizes were measured using scanning electron microscopy and dynamic light scattering. Phase composition was analyzed using Raman spectroscopy. The influence of individual parameters on the modification outcome was estimated using statistical method. The research proved that the size of obtained powders is mostly influenced by the milling speed and the amount of balls. Powders tend to form conglomerates sized up to hundreds of micrometers. Additionally, it is possible to obtain nanopowders with the size around 100 nm. Furthermore, application of additional liquid, i.e. water in the process reduces the graphitization of the powder, which takes place during dry milling.

  6. CVD diamond deposition onto dental burs

    International Nuclear Information System (INIS)

    Ali, N.; Sein, H.

    2001-01-01

    A hot-filament chemical vapor deposition (HFCVD) system has been modified to enable non-planar substrates, such as metallic wires and dental burs, to be uniformly coated with thin polycrystalline diamond films. Initially, diamond deposition was carried out on titanium and tantalum wires in order to test and optimize the system. High growth rates of the order of approx. 8 /hr were obtained when depositing diamond on titanium wires using the vertical filament arrangement. However, lower growth rates of the order of 4-5meu m/hr were obtained with diamond deposition on tantalum wires. To extend the work towards a practical biomedical application tungsten carbide dental burs were coated with diamond films. The as-grown films were found to be polycrystalline and uniform over the cutting tip. Finally, the costs relating to diamond CVD onto dental burs have been presented in this paper. The costs relating to coating different number of burs at a time and the effect of film thickness on costs have been included in this investigation. (author)

  7. CVD diamond substrates for electronic devices

    International Nuclear Information System (INIS)

    Holzer, H.

    1996-03-01

    In this study the applicability of chemical vapor deposition (CVD) diamond as a material for heat spreaders was investigated. Economical evaluations on the production of heat spreaders were also performed. For the diamond synthesis the hot-filament and microwave method were used respectively. The deposition parameters were varied in a way that free standing diamond layers with a thickness of 80 to 750 microns and different qualities were obtained. The influence of the deposition parameters on the relevant film properties was investigated and discussed. With both the hot-filament and microwave method it was possible to deposit diamond layers having a thermal conductivity exceeding 1200 W/mK and therefore to reach the quality level for commercial uses. The electrical resistivity was greater than 10 12 Ωcm. The investigation of the optical properties was done by Raman-, IR- and cathodoluminescence spectroscopy. Because of future applications of diamond-aluminium nitride composites as highly efficient heat spreaders diamond deposition an AIN was investigated. An improved substrate pretreatment prior to diamond deposition showed promising results for better performance of such composite heat spreaders. Both free standing layers and diamond-AIN composites could be cut by a CO2 Laser in Order to get an exact size geometry. A reduction of the diamond surface roughness was achieved by etching with manganese powder or cerium. (author)

  8. CVD-Graphene-Based Flexible, Thermoelectrochromic Sensor

    Directory of Open Access Journals (Sweden)

    Adam Januszko

    2017-01-01

    Full Text Available The main idea behind this work was demonstrated in a form of a new thermoelectrochromic sensor on a flexible substrate using graphene as an electrically reconfigurable thermal medium (TEChrom™. Our approach relies on electromodulation of thermal properties of graphene on poly(ethylene terephthalate (PET via mechanical destruction of a graphene layer. Graphene applied in this work was obtained by chemical vapor deposition (CVD technique on copper substrate and characterized by Raman and scanning tunneling spectroscopy. Electrical parameters of graphene were evaluated by the van der Pauw method on the transferred graphene layers onto SiO2 substrates by electrochemical delamination method. Two configurations of architecture of sensors, without and with the thermochromic layer, were investigated, taking into account the increase of voltage from 0 to 50 V and were observed by thermographic camera to define heat energy. Current-voltage characteristics obtained for the sensor with damaged graphene layer are linear, and the resistivity is independent from the current applied. The device investigated under 1000 W/m2 exhibited rise of resistivity along with increased temperature. Flexible thermoelectrochromic device with graphene presented here can be widely used as a sensor for both the military and civil monitoring.

  9. Coffee consumption is not associated with prevalent subclinical cardiovascular disease (CVD) or the risk of CVD events, in nonalcoholic fatty liver disease: results from the multi-ethnic study of atherosclerosis.

    Science.gov (United States)

    Simon, Tracey G; Trejo, Maria Esther Perez; Zeb, Irfan; Frazier-Wood, Alexis C; McClelland, Robyn L; Chung, Raymond T; Budoff, Matthew J

    2017-10-01

    Atherosclerosis and its clinical sequelae represent the leading cause of mortality among patients with nonalcoholic fatty liver disease (NAFLD). While epidemiologic data support the hepatoprotective benefits of coffee in NAFLD, whether coffee improves NAFLD-associated CVD risk is unknown. We examined 3710 ethnically-diverse participants from the Multi-Ethnic Study of Atherosclerosis (MESA) cohort, without history of known liver disease, and with available coffee data from a validated 120-item food frequency questionnaire. All participants underwent baseline non-contrast cardiac CT from which NAFLD was defined by liver:spleen ratio (L:S0. Major CVD events were defined by the first occurrence of myocardial infarction, cardiac arrest, angina, stroke, or CVD death. We used log-binomial regression to calculate the adjusted prevalence ratio (PR) for CAC>0 by coffee intake and NAFLD status, and events were compared between groups using frequency of events within adjusted Cox proportional hazard regression models. Seventeen percent (N=637) of participants met criteria for NAFLD. NAFLD participants were more likely to have elevated BMI (mean 31.1±5.5kg/m 2 vs. 28.0±5.2kg/m 2 , pcoffee consumption (p=0.97). Among NAFLD participants, coffee consumption was not associated with prevalent, baseline CAC>0 (PR=1.02 [0.98-1.07]). Over 12.8years of follow-up, 93 NAFLD and 415 non-NAFLD participants experienced a CV event. However, coffee intake was not associated with incident CVD events, in either NAFLD (HR=1.05 [0.91-1.21]) or non-NAFLD participants (HR=1.03 [0.97-1.11]). In a large, population-based cohort, coffee consumption was not associated with the prevalence of subclinical CVD, nor did coffee impact the future risk of major CVD events, regardless of underlying NAFLD status. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. CVD refractory metals and alloys for space nuclear power application

    International Nuclear Information System (INIS)

    Yang, L.; Gulden, T.D.; Watson, J.F.

    1984-01-01

    CVD technology has made significant contributions to the development of space nuclear power systems during the period 1962 to 1972. For the in-core thermionic concept, CVD technology is essential to the fabrication of the tungsten electron emitter. For the liquid metal cooled fuel pin using uranium nitride as fuel and T-111 and Nb-1 Zr as cladding, a tungsten barrier possibly produced by CVD methods is essential to the fuel-cladding compatibility at the designed operating temperature. Space power reactors may use heat pipes to transfer heat from the reactor core to the conversion system. CVD technology has been used for fabricating the heat pipe used as cross-flow heat exchanger, including the built-in channels on the condenser wall for liquid lithium return. 28 references, 17 figures

  11. Investigation of defects in CVD diamond: Influence for radiotherapy applications

    International Nuclear Information System (INIS)

    Guerrero, M.J.; Tromson, D.; Bergonzo, P.; Barrett, R.

    2005-01-01

    In this study we present the potentialities of CVD diamond as an ionisation chamber for radiotherapy applications. Trapping levels present in CVD diamond are characterised using Thermally Stimulated Current (TSC) method with X-ray sources. The influence of the corresponding defects on the detector response is investigated and compared to those observed in natural diamond. Also, their spatial distribution across a large area polycrystalline diamond ionisation chamber is discussed. Results show the relative influence of two different populations of trapping levels in CVD diamond whose effect is crucial for radiotherapy applications. To partially overcome the defect detrimental effects, we propose to use CVD diamond ionisation chambers at moderate temperatures from 70 to 100 deg. C that could be provided by self heating of the device, for a dramatically improved stability and reproducibility

  12. The gate oxide integrity of CVD tungsten polycide

    International Nuclear Information System (INIS)

    Wu, N.W.; Su, W.D.; Chang, S.W.; Tseng, M.F.

    1988-01-01

    CVD tungsten polycide has been demonstrated as a good gate material in recent very large scale integration (VLSI) technology. CVD tungsten silicide offers advantages of low resistivity, high temperature stability and good step coverage. On the other hand, the polysilicon underlayer preserves most characteristics of the polysilicon gate and acts as a stress buffer layer to absorb part of the thermal stress origin from the large thermal expansion coefficient of tungsten silicide. Nevertheless, the gate oxide of CVD tungsten polycide is less stable or reliable than that of polysilicon gate. In this paper, the gate oxide integrity of CVD tungsten polycide with various thickness combinations and different thermal processes have been analyzed by several electrical measurements including breakdown yield, breakdown fluence, room temperature TDDB, I-V characteristics, electron traps and interface state density

  13. Verification of thermo-fluidic CVD reactor model

    International Nuclear Information System (INIS)

    Lisik, Z; Turczynski, M; Ruta, L; Raj, E

    2014-01-01

    Presented paper describes the numerical model of CVD (Chemical Vapour Deposition) reactor created in ANSYS CFX, whose main purpose is the evaluation of numerical approaches used to modelling of heat and mass transfer inside the reactor chamber. Verification of the worked out CVD model has been conducted with measurements under various thermal, pressure and gas flow rate conditions. Good agreement between experimental and numerical results confirms correctness of the elaborated model.

  14. Ion beam figuring of CVD silicon carbide mirrors

    Science.gov (United States)

    Gailly, P.; Collette, J.-P.; Fleury Frenette, K.; Jamar, C.

    2017-11-01

    Optical and structural elements made of silicon carbide are increasingly found in space instruments. Chemical vapor deposited silicon carbide (CVD-SiC) is used as a reflective coating on SiC optics in reason of its good behavior under polishing. The advantage of applying ion beam figuring (IBF) to CVD-SiC over other surface figure-improving techniques is discussed herein. The results of an IBF sequence performed at the Centre Spatial de Liège on a 100 mm CVD-SiC mirror are reported. The process allowed to reduce the mirror surface errors from 243 nm to 13 nm rms . Beside the surface figure, roughness is another critical feature to consider in order to preserve the optical quality of CVD-SiC . Thus, experiments focusing on the evolution of roughness were performed in various ion beam etching conditions. The roughness of samples etched at different depths down to 3 ≠m was determined with an optical profilometer. These measurements emphasize the importance of selecting the right combination of gas and beam energy to keep roughness at a low level. Kaufman-type ion sources are generally used to perform IBF but the performance of an end-Hall ion source in figuring CVD-SiC mirrors was also evaluated in this study. In order to do so, ion beam etching profiles obtained with the end-Hall source on CVD-SiC were measured and used as a basis for IBF simulations.

  15. CVD Diamond Sensors In Detectors For High Energy Physics

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00334150; Trischuk, William

    At the end of the next decade an upgrade of the Large Hadron Collider (LHC) to High Luminosity LHC (HL-LHC) is planned which requires the development of new radiation tolerant sensor technology. Diamond is an interesting material for use as a particle detector in high radiation environments. The large band gap ($5.47\\,\\text{eV}$) and the large displacement energy suggest that diamond is a radiation tolerant detector material. In this Thesis the capability of Chemical Vapor Deposition (CVD) diamond as such a sensor technology is investigated. The radiation damage constant for $800\\,\\text{MeV}$ protons is measured using single crystalline CVD (scCVD) and polycrystalline CVD (pCVD) diamonds irradiated to particle fluences up to $12 \\times 10^{15}\\,\\text{p/cm}^2$. In addition the signal response of a pCVD diamond detector after an irradiation to $12 \\times 10^{15}\\,\\text{p/cm}^2$ is investigated to determine if such a detector can be operated efficiently in the expected HL-LHC environment. By using electrodes em...

  16. Cardiovascular Risks Associated with Incident and Prevalent Periodontal Disease

    Science.gov (United States)

    Yu, Yau-Hua; Chasman, Daniel I; Buring, Julie E; Rose, Lynda; Ridker, Paul M

    2014-01-01

    Aim While prevalent periodontal disease associates with cardiovascular risk, little is known about how incident periodontal disease influences future vascular risk. We compared effects of incident versus prevalent periodontal disease in developing major cardiovascular diseases (CVD), myocardial infarction (MI), ischemic stroke and total CVD. Material and Methods In a prospective cohort of 39863 predominantly white women, age ≥ 45 years and free of cardiovascular disease at baseline were followed for an average of 15.7 years. Cox proportional hazard models with time-varying periodontal status (prevalent [18%], incident [7.3%] vs. never [74.7%]) were used to assess future cardiovascular risks. Results Incidence rates of all CVD outcomes were higher in women with prevalent or incident periodontal disease. For women with incident periodontal disease, risk factor adjusted hazard ratios (HRs) were 1.42 (95% CI, 1.14–1.77) for major CVD, 1.72 (1.25–2.38) for MI, 1.41(1.02–1.95) for ischemic stroke, and 1.27(1.06–1.52) for total CVD. For women with prevalent periodontal disease, adjusted HRs were 1.14 (1.00–1.31) for major CVD, 1.27 (1.04–1.56) for MI, 1.12(0.91–1.37) for ischemic stroke, and 1.15(1.03–1.28) for total CVD. Conclusion New cases of periodontal disease, not just those that are pre-existing, place women at significantly elevated risks for future cardiovascular events. PMID:25385537

  17. Low-temperature graphene synthesis using microwave plasma CVD

    International Nuclear Information System (INIS)

    Yamada, Takatoshi; Kim, Jaeho; Ishihara, Masatou; Hasegawa, Masataka

    2013-01-01

    The graphene chemical vapour deposition (CVD) technique at substrate temperatures around 300 °C by a microwave plasma sustained by surface waves (surface wave plasma chemical vapour deposition, SWP-CVD) is discussed. A low-temperature, large-area and high-deposition-rate CVD process for graphene films was developed. It was found from Raman spectra that the deposited films on copper (Cu) substrates consisted of high-quality graphene flakes. The fabricated graphene transparent conductive electrode showed uniform optical transmittance and sheet resistance, which suggests the possibility of graphene for practical electrical and optoelectronic applications. It is intriguing that graphene was successfully deposited on aluminium (Al) substrates, for which we did not expect the catalytic effect to decompose hydrocarbon and hydrogen molecules. We developed a roll-to-roll SWP-CVD system for continuous graphene film deposition towards industrial mass production. A pair of winder and unwinder systems of Cu film was installed in the plasma CVD apparatus. Uniform Raman spectra were confirmed over the whole width of 297 mm of Cu films. We successfully transferred the deposited graphene onto PET films, and confirmed a transmittance of about 95% and a sheet resistance of less than 7 × 10 5 Ω/sq.

  18. Low-temperature graphene synthesis using microwave plasma CVD

    Science.gov (United States)

    Yamada, Takatoshi; Kim, Jaeho; Ishihara, Masatou; Hasegawa, Masataka

    2013-02-01

    The graphene chemical vapour deposition (CVD) technique at substrate temperatures around 300 °C by a microwave plasma sustained by surface waves (surface wave plasma chemical vapour deposition, SWP-CVD) is discussed. A low-temperature, large-area and high-deposition-rate CVD process for graphene films was developed. It was found from Raman spectra that the deposited films on copper (Cu) substrates consisted of high-quality graphene flakes. The fabricated graphene transparent conductive electrode showed uniform optical transmittance and sheet resistance, which suggests the possibility of graphene for practical electrical and optoelectronic applications. It is intriguing that graphene was successfully deposited on aluminium (Al) substrates, for which we did not expect the catalytic effect to decompose hydrocarbon and hydrogen molecules. We developed a roll-to-roll SWP-CVD system for continuous graphene film deposition towards industrial mass production. A pair of winder and unwinder systems of Cu film was installed in the plasma CVD apparatus. Uniform Raman spectra were confirmed over the whole width of 297 mm of Cu films. We successfully transferred the deposited graphene onto PET films, and confirmed a transmittance of about 95% and a sheet resistance of less than 7 × 105 Ω/sq.

  19. Test of radiation hardness of pcCVD detectors

    Energy Technology Data Exchange (ETDEWEB)

    Schlemme, Steffen [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Technische Universitaet Darmstadt (Germany); Enders, Joachim [Technische Universitaet Darmstadt (Germany); Figuera, P.; Salamone, S. [LNS-INFN Catania (Italy); Fruehauf, J.; Kis, Mladen; Kratz, A.; Kurz, N.; Loechner, S.; Nociforo, Chiara; Schirru, Fabio; Szczepanczyk, B.; Traeger, M.; Visinka, R. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Musumarra, A. [LNS-INFN Catania (Italy); University of Catania (Italy)

    2016-07-01

    The new in-flight separator Super-FRS is under construction at the Facility for Antiproton and Ion Research (FAIR, Darmstadt). Ion rates up to 3 x 10{sup 11} {sup 238}U/spill demand an adaption of detectors to a high radiation environment. A test experiment to investigate the radiation hardness of polycrystalline diamond detectors (pcCVD) was performed at the LNS-INFN in Catania using a {sup 12}C beam at 62 MeV/u and intensities of up to 1.5 pnA. The setup consisted of pcCVD strip detectors to measure the beam profile, a single crystal diamond detector to calibrate the ionisation chamber working in current mode as a beam intensity monitor and a pcCVD sample to be irradiated. The IC used was designed for FAIR and showed a stable counting rate allowing us to calibrate and perform beam intensity measurements with it. The total measured counts on the sample were 8.25 x 10{sup 11} counts/mm{sup 2} over a period of 60 hours. Digital waveforms of the pcCVD signals were taken with an oscilloscope and analysed. The results showed no change of the pcCVD signal properties during the entire irradiation.

  20. Number of recent stressful life events and incident cardiovascular disease: Moderation by lifetime depressive disorder.

    Science.gov (United States)

    Berntson, Jessica; Patel, Jay S; Stewart, Jesse C

    2017-08-01

    We investigated whether number of recent stressful life events is associated with incident cardiovascular disease (CVD) and whether this relationship is stronger in adults with a history of clinical depression. Prospective data from 28,583 U.S. adults (mean age=45years) initially free of CVD who participated in Waves 1 (2001-2002) and 2 (2004-2005) of the National Epidemiologic Survey on Alcohol and Related Conditions (NESARC) were examined. Number of past-year stressful life events (Wave 1), lifetime depressive disorder (Wave 1), and incident CVD (Wave 2) were determined by structured interviews. There were 1069 cases of incident CVD. Each additional stressful life event was associated with a 15% increased odds of incident CVD [Odds Ratio (OR)=1.15, 95% Confidence Interval (CI): 1.11, 1.19]. As hypothesized, a stressful life events by lifetime depressive disorder interaction was detected (P=0.003). Stratified analyses indicated that stressful life events had a stronger association with incident CVD among adults with (OR=1.18, 95% CI: 1.10, 1.27, n=4908) versus without (OR=1.10, 95% CI: 1.07, 1.14, n=23,675) a lifetime depressive disorder. Our findings suggest that a greater number of recent stressful life events elevate the risk of new-onset CVD and that this risk is potentiated in adults with a history of clinical depression. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Relations of serum phosphorus and calcium levels to the incidence of cardiovascular disease in the community.

    Science.gov (United States)

    Dhingra, Ravi; Sullivan, Lisa M; Fox, Caroline S; Wang, Thomas J; D'Agostino, Ralph B; Gaziano, J Michael; Vasan, Ramachandran S

    2007-05-14

    Higher levels of serum phosphorus and the calcium-phosphorus product are associated with increased mortality from cardiovascular disease (CVD) in patients with chronic kidney disease (CKD) or prior CVD. However, it is unknown if serum phosphorus levels influence vascular risk in individuals without CKD or CVD. We prospectively evaluated 3368 Framingham Offspring study participants (mean age, 44 years; 51% were women) free of CVD and CKD. We used multivariable Cox models to relate serum phosphorus and calcium levels to CVD incidence. On follow-up (mean duration, 16.1 years), there were 524 incident CVD events (159 in women). In multivariable analyses and adjusting for established risk factors and additionally for glomerular filtration rate and for hemoglobin, serum albumin, proteinuria, and C-reactive protein levels, a higher level of serum phosphorus was associated with an increased CVD risk in a continuous fashion (adjusted hazard ratio per increment of milligrams per deciliter, 1.31; 95% confidence interval, 1.05-1.63; P=.02; P value for trend across quartiles = .004). Individuals in the highest serum phosphorus quartile experienced a multivariable-adjusted 1.55-fold CVD risk (95% confidence interval, 1.16%-2.07%; P=.004) compared with those in the lowest quartile. These findings remained robust in time-dependent models that updated CVD risk factors every 4 years and in analyses restricted to individuals without proteinuria and an estimated glomerular filtration rate greater than 90 mL/min per 1.73 m(2). Serum calcium was not related to CVD risk. Higher serum phosphorus levels are associated with an increased CVD risk in individuals free of CKD and CVD in the community. These observations emphasize the need for additional research to elucidate the potential link between phosphorus homeostasis and vascular risk.

  2. Risk of incident cardiovascular events amongst individuals with anxiety and depression:A prospective cohort study in the east London primary care database

    OpenAIRE

    Mathur, R.; Pérez-Pinar, M.; Foguet-Boreu, Q.; Ayis, S.; Ayerbe, L.

    2016-01-01

    Background It is unknown how risk of myocardial infarction and stroke differ for patients with and without anxiety or depression, and whether this risk can be explained by demographics, medication use, cardiovascular risk factors. The aim of this study is to quantify differences in risk of non-fatal MI or stroke among patients with anxiety or depression. Methods Prospective cohort study examining risk of incident MI and stroke between March 2005 and March 2015 for 524,952 patients aged 30 and...

  3. Adhesion of non-selective CVD tungsten to silicon dioxide

    International Nuclear Information System (INIS)

    Woodruff, D.W.; Wilson, R.H.; Sanchez-Martinez, R.A.

    1986-01-01

    Adhesion of non-selective, CVD tungsten to silicon dioxide is a critical issue in the development of tungsten as a metalization for VLSI circuitry. Without special adhesion promoters, tungsten deposited from WF/sub 6/ and H/sub 2/ has typically failed a standard tape test over all types of silicon oxides and nitrides. The reasons for failure of thin films, and CVD tungsten in particular are explored along with standard techniques for improving adhesion of thin films. Experiments are reported which include a number of sputtered metals as adhesion promoters, as well as chemical and plasma treatment of the oxide surface. Sputtered molybdenum is clearly the superior adhesion promoting layer from these tests. Traditional adhesion layers such as chromium or titanium failed as adhesion layers for CVD tungsten possibly due to chemical reactions between the WF/sub 6/ and Cr or Ti

  4. The formation of tritium permeation barriers by CVD

    International Nuclear Information System (INIS)

    Forcey, K.S.; Perujo, A.; Reiter, F.; Lolli-Ceroni, P.L.

    1993-01-01

    The effectiveness as permeation barriers of the following CVD coatings have been investigated: TiC (1 to 2 μm in thickness); a bi-layer of TiN on TiC (3 μm total thickness) and CVD Al 2 O 3 on a TiN/TiC bi-layer. The substrate materials were TZM (a Mo alloy) and 316L stainless steel in the form of discs of diameter 48 mm and thickness 0.1 or 1 mm. Permeation measurements were performed in the temperature range 515-742 K using deuterium at pressures in the range 1-50 kPa. CVD layers were shown to form reasonably effective permeation barriers. At a temperature of 673 K TiC is around 6000 times less permeable to deuterium than 316L stainless steel. (orig.)

  5. The inverse association of incident cardiovascular disease with plasma bilirubin is unaffected by adiponectin

    NARCIS (Netherlands)

    Dullaart, Robin P. F.; Boersema, Jeltje; Lefrandt, Joop D.; Wolffenbuttel, Bruce H. R.; Bakker, Stephan J. L.

    Objective: Bilirubin may protect against atherosclerotic cardiovascular disease (CVD). The heme oxygenase pathway is crucial for bilirubin generation, and is stimulated by adiponectin. We tested the relationship of plasma bilirubin with adiponectin, and determined whether the association of incident

  6. Graphene Synthesis by Plasma-Enhanced CVD Growth with Ethanol

    OpenAIRE

    Campo, T.; Cotto, M.; Márquez, F.; Elizalde, E.; Morant, C.

    2016-01-01

    A modified route to synthesize graphene flakes is proposed using the Chemical Vapor Deposition (CVD) technique, by using copper substrates as supports. The carbon source used was ethanol, the synthesis temperature was 950°C and the pressure was controlled along the whole process. In this CVD synthesis process the incorporation of the carbon source was produced at low pressure and 950°C inducing the appearance of a plasma blue flash inside the quartz tube. Apparently, the presence of this plas...

  7. Correlation of CVD Diamond Electron Emission with Film Properties

    Science.gov (United States)

    Bozeman, S. P.; Baumann, P. K.; Ward, B. L.; Nemanich, R. J.; Dreifus, D. L.

    1996-03-01

    Electron field emission from metals is affected by surface morphology and the properties of any dielectric coating. Recent results have demonstrated low field electron emission from p-type diamond, and photoemission measurements have identified surface treatments that result in a negative electron affinity (NEA). In this study, the field emission from diamond is correlated with surface treatment, surface roughness, and film properties (doping and defects). Electron emission measurements are reported on diamond films synthesized by plasma CVD. Ultraviolet photoemission spectroscopy indicates that the CVD films exhibit a NEA after exposure to hydrogen plasma. Field emission current-voltage measurements indicate "threshold voltages" ranging from approximately 20 to 100 V/micron.

  8. Radiation tolerance of CVD diamond detectors for pions and protons

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D' Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F. E-mail: f.hartjes@nikhef.nl; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M

    2002-01-11

    The paper gives new results on the radiation tolerance of CVD diamond for irradiation with 300 MeV/c pions and 24 GeV/c protons. The measured charge signal spectrum is compared at several irradiation levels with the spectrum calculated by a model. Irradiation by particles causes damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model show that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal.

  9. Radiation tolerance of CVD diamond detectors for pions and protons

    Science.gov (United States)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.

    2002-01-01

    The paper gives new results on the radiation tolerance of CVD diamond for irradiation with 300 MeV/ c pions and 24 GeV/ c protons. The measured charge signal spectrum is compared at several irradiation levels with the spectrum calculated by a model. Irradiation by particles causes damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model show that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal.

  10. Application of Cat-CVD for ULSI technology

    International Nuclear Information System (INIS)

    Akasaka, Yoichi

    2008-01-01

    The ULSI technology has been following Moore's law into the sub-100 nm era, although several challenging technical issues must be resolved. This paper describes possible application of Cat-CVD for ULSI technology beyond the 45 nm node. Especially, Cat-CVD SiN film for a transistor gate sidewall and/or a pre-metallic liner layer, and removal of photo resist (ash) by Cat-induced hydrogen atoms in the interconnect structure with an extreme low-k material are mainly discussed

  11. Radiation tolerance of CVD diamond detectors for pions and protons

    International Nuclear Information System (INIS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.

    2002-01-01

    The paper gives new results on the radiation tolerance of CVD diamond for irradiation with 300 MeV/c pions and 24 GeV/c protons. The measured charge signal spectrum is compared at several irradiation levels with the spectrum calculated by a model. Irradiation by particles causes damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model show that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal

  12. Prevalencia de accidentes de tránsito no fatales en México: resultados de la ENSANUT 2006 Prevalence of non-fatal road traffic injuries in Mexico: results from ENSANUT 2006

    Directory of Open Access Journals (Sweden)

    Leticia Ávila-Burgos

    2008-01-01

    Full Text Available OBJETIVO: Determinar la prevalencia y distribución de los accidentes de tránsito no fatales (ATNF en México. MATERIAL Y MÉTODOS: Se utilizaron datos de la ENSANUT 2006. En los hogares visitados se seleccionó a un adulto, un adolescente y un niño, hasta conformar una muestra de 94197 sujetos que representa a la N de 102 886 482 individuos. La variable dependiente fue la prevalencia de ATNF en los 12 meses anteriores a la encuesta. RESULTADOS: La prevalencia de accidentes (de tránsito o no fue de 6.0% y de esa cifra 16.7% correspondió a ATNF. Los hombres del grupo de 20 a 44 años, los habitantes de áreas urbanas y los de mejor nivel socioeconómico (NSE presentaron mayor prevalencia (pOBJECTIVE: To determine non-fatal road traffic injuries (NFRTI prevalence and its distribution in Mexico. MATERIAL AND METHODS: Data from ENSANUT Survey 2006 were used. Using simple random sampling, one adult, one adolescent and one child were selected in each household, constituting a final sample of 94 197 representing an N of 102 886 482 people. The dependent variable was the prevalence of road traffic injuries (RTI during the 12 months prior to the survey. RESULTS: The general accident prevalence was 6.0%; 16.7% corresponded to NFRTI. Men in the 20 to 44 age group living in urban areas and with high socioeconomic status had a higher RTI prevalence (p<0.05. Jalisco, Aguascalientes and Sonora were states with the highest prevalence of RTI, while Guerrero, Michoacan and Oaxaca were those with the lowest. CONCLUSIONS: NFRTI are frequent in Mexico and they are concentrated among men in productive ages in urban areas; they are associated with socioeconomic status at the individual level and with the state's development at the population level.

  13. CVD-graphene for low equivalent series resistance in rGO/CVD-graphene/Ni-based supercapacitors

    Science.gov (United States)

    Kwon, Young Hwi; Kumar, Sunil; Bae, Joonho; Seo, Yongho

    2018-05-01

    Reduced equivalent series resistance (ESR) is necessary, particularly at a high current density, for high performance supercapacitors, and the interface resistance between the current collector and electrode material is one of the main components of ESR. In this report, we have optimized chemical vapor deposition-grown graphene (CVD-G) on a current collector (Ni-foil) using reduced graphene oxide as an active electrode material to fabricate an electric double layer capacitor with reduced ESR. The CVD-G was grown at different cooling rates—20 °C min‑1, 40 °C min‑1 and 100 °C min‑1—to determine the optimum conditions. The lowest ESR, 0.38 Ω, was obtained for a cell with a 100 °C min‑1 cooling rate, while the sample without a CVD-G interlayer exhibited 0.80 Ω. The CVD-G interlayer-based supercapacitors exhibited fast CD characteristics with high scan rates up to 10 Vs‑1 due to low ESR. The specific capacitances deposited with CVD-G were in the range of 145.6 F g‑1–213.8 F g‑1 at a voltage scan rate of 0.05 V s‑1. A quasi-rectangular behavior was observed in the cyclic voltammetry curves, even at very high scan rates of 50 and 100 V s‑1, for the cell with optimized CVD-G at higher cooling rates, i.e. 100 °C min‑1.

  14. Atherosclerosis profile and incidence of cardiovascular events: a population-based survey

    Directory of Open Access Journals (Sweden)

    Bullano Michael F

    2009-09-01

    Full Text Available Abstract Background Atherosclerosis is a chronic progressive disease often presenting as clinical cardiovascular disease (CVD events. This study evaluated the characteristics of individuals with a diagnosis of atherosclerosis and estimated the incidence of CVD events to assist in the early identification of high-risk individuals. Methods Respondents to the US SHIELD baseline survey were followed for 2 years to observe incident self-reported CVD. Respondents had subclinical atherosclerosis if they reported a diagnosis of narrow or blocked arteries/carotid artery disease without a past clinical CVD event (heart attack, stroke or revascularization. Characteristics of those with atherosclerosis and incident CVD were compared with those who did not report atherosclerosis at baseline but had CVD in the following 2 years using chi-square tests. Logistic regression model identified characteristics associated with atherosclerosis and incident events. Results Of 17,640 respondents, 488 (2.8% reported having subclinical atherosclerosis at baseline. Subclinical atherosclerosis was associated with age, male gender, dyslipidemia, circulation problems, hypertension, past smoker, and a cholesterol test in past year (OR = 2.2 [all p Conclusion Self-report of subclinical atherosclerosis identified an extremely high-risk group with a >25% risk of a CVD event in the next 2 years. These characteristics may be useful for identifying individuals for more aggressive diagnostic and therapeutic efforts.

  15. Modelling and analysis of CVD processes for ceramic membrane preparation

    NARCIS (Netherlands)

    Brinkman, H.W.; Cao, G.Z.; Meijerink, J.; de Vries, Karel Jan; Burggraaf, Anthonie

    1993-01-01

    A mathematical model is presented that describes the modified chemical vapour deposition (CVD) process (which takes place in advance of the electrochemical vapour deposition (EVD) process) to deposit ZrO2 inside porous media for the preparation and modification of ceramic membranes. The isobaric

  16. High plasma cholesteryl ester transfer protein levels may favour reduced incidence of cardiovascular events in men with low triglycerides

    NARCIS (Netherlands)

    Borggreve, Susanna E.; Hillege, Hans L.; Dallinga-Thie, Geesje M.; de Jong, Paul E.; Wolffenbuttel, Bruce H. R.; Grobbee, Diederik E.; van Tol, Arie; Dullaart, Robin P. F.

    Aims High cholesteryl ester transfer protein (CETP) concentrations are associated with increased risk of cardiovascular disease (CVD) in subjects with high triglycerides. We determined the relationship of plasma CETP with incident CVD in a population with relatively low triglycerides. Methods and

  17. CVD polycrystalline diamond. A novel neutron detector and applications

    International Nuclear Information System (INIS)

    Mongkolnavin, R.

    1998-01-01

    Chemical Vapour Deposition (CVD) Polycrystalline Diamond film has been investigated as a low noise sensor for beta particles, gammas and neutrons using High Energy Physics technologies. Its advantages and disadvantages have been explored in comparison with other particle detectors such as silicon detector and other plastic scintillators. The performance and characteristic of the diamond detector have been fully studied and discussed. These studies will lead to a better understanding of how CVD diamonds perform as a detector and how to improve their performance under various conditions. A CVD diamond detector model has been proposed which is an attempt to explain the behaviour of such an extreme detector material. A novel neutron detector is introduced as a result of these studies. A good thermal and fast neutron detector can be fabricated with CVD diamond with new topologies. This detector will perform well without degradation in a high neutron radiation environment, as diamond is known to be radiation hard. It also offers better neutrons and gammas discrimination for high gamma background applications compared to other semiconductor detectors. A full simulation of the detector has also been done using GEANT, a Monte-Carlo simulation program for particle detectors. Simulation results show that CVD diamond detectors with this novel topology can detect neutrons with great directionality. Experimental work has been done on this detector in a nuclear reactor environment and accelerator source. A novel neutron source which offers a fast pulse high-energy neutrons has also been studied. With this detector, applications in neutron spectrometer for low-Z material have been pursued with various neutron detection techniques. One of these is a low-Z material identification system. The system has been designed and simulated for contraband luggage interrogation using the detector and the novel neutron source. Also other neutron related applications have been suggested. (author)

  18. CVD polycrystalline diamond. A novel neutron detector and applications

    International Nuclear Information System (INIS)

    Mongkolnavin, R.

    1998-07-01

    Chemical Vapour Deposition (CVD) Polycrystalline Diamond film has been investigated as a low noise sensor for beta particles, gammas and neutrons using High Energy Physics technologies. Its advantages and disadvantages have been explored in comparison with other particle detectors such as silicon detector and other plastic scintillators. The performance and characteristic of the diamond detector have been fully studied and discussed. These studies will lead to a better understanding of how CVD diamonds perform as a detector and how to improve their performance under various conditions. A CVD diamond detector model has been proposed which is an attempt to explain the behaviour of such an extreme detector material. A novel neutron detector is introduced as a result of these studies. A good thermal and fast neutron detector can be fabricated with CVD diamond with new topologies. This detector will perform well without degradation in a high neutron radiation environment, as diamond is known to be radiation-hard. It also offers better neutrons and gammas discrimination for high gamma background applications compared to other semiconductor detectors. A full simulation of the detector has also been done using GEANT, a Monte Carlo simulation program for particle detectors. Simulation results show that CVD diamond detectors with this novel topology can detect neutrons with great directionality. Experimental work has been done on this detector in a nuclear reactor environment and accelerator source. A novel neutron source which offers a fast pulse high-energy neutrons has also been studied. With this detector, applications in neutron spectrometry for low-Z material have been pursued with various neutron detection techniques. One of these is a low-Z material identification system. The system has been designed and simulated for contraband luggage interrogation using the detector and the novel neutron source. (author)

  19. Changes in CVD risk factors in the activity counseling trial

    Directory of Open Access Journals (Sweden)

    Meghan Baruth

    2011-01-01

    Full Text Available Meghan Baruth1, Sara Wilcox1, James F Sallis3, Abby C King4,5, Bess H Marcus6, Steven N Blair1,21Department of Exercise Science, 2Department of Epidemiology and Biostatistics, Arnold School of Public Health, University of South Carolina, Public Health Research Center, Columbia, SC, USA; 3Department of Psychology, San Diego State University, San Diego, CA, USA; 4Department of Health Research and Policy, 5Stanford Prevention Research Center, Department of Medicine, Stanford University School of Medicine, Stanford, CA, USA; 6Behavioral and Social Sciences Section, Brown University Program in Public Health, Providence, RI, USAAbstract: Primary care facilities may be a natural setting for delivering interventions that focus on behaviors that improve cardiovascular disease (CVD risk factors. The purpose of this study was to examine the 24-month effects of the Activity Counseling Trial (ACT on CVD risk factors, to examine whether changes in CVD risk factors differed according to baseline risk factor status, and to examine whether changes in fitness were associated with changes in CVD risk factors. ACT was a 24-month multicenter randomized controlled trial to increase physical activity. Participants were 874 inactive men and women aged 35–74 years. Participants were randomly assigned to one of three arms that varied by level of counseling, intensity, and resource requirements. Because there were no significant differences in change over time between arms on any of the CVD risk factors examined, all arms were combined, and the effects of time, independent of arm, were examined separately for men and women. Time × Baseline risk factor status interactions examined whether changes in CVD risk factors differed according to baseline risk factor status. Significant improvements in total cholesterol, high-density lipoprotein cholesterol (HDL-C and low-density lipoprotein cholesterol, the ratio of total cholesterol to HDL-C, and triglycerides were seen in

  20. COMPARATIVE EVALUATION OF RISK FACTORS FOR CARDIOVASCULAR DISEASE (CVD) IN GENETICALLY PREDISPOSED RATS

    Science.gov (United States)

    Rodent CVD models are increasingly used for understanding individual differences in susceptibility to environmental stressors such as air pollution. We characterized pathologies and a number of known human risk factors of CVD in genetically predisposed, male young adult Spontaneo...

  1. Thermodynamic study of CVD-ZrO2 phase diagrams

    International Nuclear Information System (INIS)

    Torres-Huerta, A.M.; Vargas-Garcia, J.R.; Dominguez-Crespo, M.A.; Romero-Serrano, J.A.

    2009-01-01

    Chemical vapor deposition (CVD) of zirconium oxide (ZrO 2 ) from zirconium acetylacetonate Zr(acac) 4 has been thermodynamically investigated using the Gibbs' free energy minimization method and the FACTSAGE program. Thermodynamic data Cp o , ΔH o and S o for Zr(acac) 4 have been estimated using the Meghreblian-Crawford-Parr and Benson methods because they are not available in the literature. The effect of deposition parameters, such as temperature and pressure, on the extension of the region where pure ZrO 2 can be deposited was analyzed. The results are presented as calculated CVD stability diagrams. The phase diagrams showed two zones, one of them corresponds to pure monoclinic phase of ZrO 2 and the other one corresponds to a mix of monoclinic phase of ZrO 2 and graphite carbon.

  2. Performance of irradiated CVD diamond micro-strip sensors

    International Nuclear Information System (INIS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; Plano, R.; Somalwar, S.V.; Thomson, G.B.

    2002-01-01

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a β-source and the performance before and after intense (>10 15 /cm 2 ) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2x10 15 p/cm 2 lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9x10 15 π/cm 2 lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations

  3. Performance of irradiated CVD diamond micro-strip sensors

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D' Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D. E-mail: dirk.meier@cern.ch; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; Plano, R.; Somalwar, S.V.; Thomson, G.B

    2002-01-11

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a {beta}-source and the performance before and after intense (>10{sup 15}/cm{sup 2}) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2x10{sup 15} p/cm{sup 2} lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9x10{sup 15} {pi}/cm{sup 2} lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.

  4. Pulse height distribution and radiation tolerance of CVD diamond detectors

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dangelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Han, S.; Hartjes, F. E-mail: f.hartjes@nikhef.nl; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trawick, M.; Trischuk, W.; D.Tromson,; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; White, C.; Zeuner, W.; Zoeller, M.; Fenyvesi, A.; Molnar, J.; Sohler, D

    2000-06-01

    The paper reviews measurements of the radiation tolerance of CVD diamond for irradiation with 24 GeV/c protons, 300 MeV/c pions and 1 MeV neutrons. For proton and neutron irradiation, the measured charge signal spectrum is compared with the spectrum calculated by a model. Irradiation by particles causes radiation damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model shows that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. In addition, we observed after proton irradiation at the charge signal spectrum a decrease of the number of small signals. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal.

  5. Performance of irradiated CVD diamond micro-strip sensors

    CERN Document Server

    Adam, W; Bergonzo, P; Bertuccio, G; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; D'Angelo, P; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Hallewell, G D; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Kass, R; Koeth, T W; Krammer, Manfred; Lo Giudice, A; Lü, R; MacLynne, L; Manfredotti, C; Meier, D; Mishina, M; Moroni, L; Noomen, J; Oh, A; Pan, L S; Pernicka, Manfred; Peitz, A; Perera, L P; Pirollo, S; Procario, M; Riester, J L; Roe, S; Rousseau, L; Rudge, A; Russ, J; Sala, S; Sampietro, M; Schnetzer, S R; Sciortino, S; Stelzer, H; Stone, R; Suter, B; Tapper, R J; Tesarek, R J; Trischuk, W; Tromson, D; Vittone, E; Walsh, A M; Wedenig, R; Weilhammer, Peter; Wetstein, M; White, C; Zeuner, W; Zöller, M

    2002-01-01

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a $\\beta$-source and the performance before and after intense ($>10^{15}/{\\rm cm^2}$) proton- and pion-irradiations. We find that low dose irradiations increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiations with protons ($2.2\\times 10^{15}~p/{\\rm cm^2}$) lowers the signal-to-noise ratio slightly. Intense irradiation with pions ($2.9\\times 10^{15}~\\pi/{\\rm cm^2}$) lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.

  6. Performance of irradiated CVD diamond micro-strip sensors

    Science.gov (United States)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; Plano, R.; Somalwar, S. V.; Thomson, G. B.

    2002-01-01

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a β-source and the performance before and after intense (>10 15/cm 2) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2×10 15 p/ cm2 lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9×10 15 π/ cm2 lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.

  7. Assessment of CVD diamond as a thermoluminescence dosemeter material

    International Nuclear Information System (INIS)

    Borchi, E.; Furetta, C.; Leroy, C.

    1996-01-01

    Diamond has a low atomic number (Z = 6) and is therefore essentially soft tissue (Z = 7.4) equivalent. As such, diamond is an attractive material for applications in dosimetry in which the radiation absorption in the sensor material should be as close as possible to that of soft tissue. Synthetic diamond prepared by chemical vapour deposition (CVD) offers an attractive option for this application. The aim of the present work is to report results on the thermoluminescence (TL) properties of CVD diamond samples. The annealing procedures, the linearity of the TL response as a function of dose, a short-term fading experiment and some kinetic properties have been investigated and are reported here. (Author)

  8. Cold Vacuum Drying (CVD) OCRWM Loop Error Determination

    International Nuclear Information System (INIS)

    PHILIPP, B.L.

    2000-01-01

    Characterization is specifically identified by the Richland Operations Office (RL) for the Office of Civilian Radioactive Waste Management (OCRWM) of the US Department of Energy (DOE), as requiring application of the requirements in the Quality Assurance Requirements and Description (QARD) (RW-0333P DOE 1997a). Those analyses that provide information that is necessary for repository acceptance require application of the QARD. The cold vacuum drying (CVD) project identified the loops that measure, display, and record multi-canister overpack (MCO) vacuum pressure and Tempered Water (TW) temperature data as providing OCRWM data per Application of the Office of Civilian Radioactive Waste Management (OCRWM) Quality Assurance Requirements to the Hanford Spent Nuclear Fuel Project HNF-SD-SNF-RPT-007. Vacuum pressure transmitters (PT 1*08, 1*10) and TW temperature transmitters (TIT-3*05, 3*12) are used to verify drying and to determine the water content within the MCO after CVD

  9. Pulse height distribution and radiation tolerance of CVD diamond detectors

    CERN Document Server

    Adam, W; Bergonzo, P; Bertuccio, G; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; D'Angelo, P; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Grigoriev, E; Hallewell, G D; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Karl, C; Kass, R; Krammer, Manfred; Lo Giudice, A; Lü, R; Manfredotti, C; Meier, D; Mishina, M; Moroni, L; Oh, A; Pan, L S; Pernicka, Manfred; Peitz, A; Pirollo, S; Polesello, P; Procario, M; Riester, J L; Roe, S; Rousseau, L; Rudge, A; Russ, J; Sala, S; Sampietro, M; Schnetzer, S R; Sciortino, S; Stelzer, H; Stone, R; Suter, B; Tapper, R J; Tesarek, R J; Trawick, M L; Trischuk, W; Tromson, D; Vittone, E; Walsh, A M; Wedenig, R; Weilhammer, Peter; White, C; Zeuner, W; Zöller, M; Fenyvesi, A; Molnár, J; Sohler, D

    2000-01-01

    The paper reviews measurements of the radiation tolerance of CVD diamond for irradiation with 24 GeV/c protons, 300 MeV/c pions and 1 MeV neutrons. For proton and neutron irradiation, the measured charge signal spectrum is compared with the spectrum calculated by a model. Irradiation by particles causes radiation damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model shows that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. In addition, we observed after proton irradiation at the charge signal spectrum a decrease of the number of small signals. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal. (11 refs).

  10. Pulse height distribution and radiation tolerance of CVD diamond detectors

    International Nuclear Information System (INIS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dangelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trawick, M.; Trischuk, W.; D.Tromson,; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; White, C.; Zeuner, W.; Zoeller, M.; Fenyvesi, A.; Molnar, J.; Sohler, D.

    2000-01-01

    The paper reviews measurements of the radiation tolerance of CVD diamond for irradiation with 24 GeV/c protons, 300 MeV/c pions and 1 MeV neutrons. For proton and neutron irradiation, the measured charge signal spectrum is compared with the spectrum calculated by a model. Irradiation by particles causes radiation damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model shows that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. In addition, we observed after proton irradiation at the charge signal spectrum a decrease of the number of small signals. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal

  11. Crystal growth of CVD diamond and some of its peculiarities

    CERN Document Server

    Piekarczyk, W

    1999-01-01

    Experiments demonstrate that CVD diamond can form in gas environments that are carbon undersaturated with respect to diamond. This fact is, among others, the most serious violation of principles of chemical thermodynamics. In this $9 paper it is shown that none of the principles is broken when CVD diamond formation is considered not a physical process consisting in growth of crystals but a chemical process consisting in accretion of macro-molecules of polycyclic $9 saturated hydrocarbons belonging to the family of organic compounds the smallest representatives of which are adamantane, diamantane, triamantane and so forth. Since the polymantane macro-molecules are in every respect identical with $9 diamond single crystals with hydrogen-terminated surfaces, the accretion of polymantane macro- molecules is a process completely equivalent to the growth of diamond crystals. However, the accretion of macro-molecules must be $9 described in a way different from that used to describe the growth of crystals because so...

  12. Parameterisation of radiation effects on CVD diamond for proton irradiation

    International Nuclear Information System (INIS)

    Hartjes, F.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knoepfle, K.T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P.F.; Manfredotti, C.; Marshall, R.D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L.S.; Palmieri, V.G.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Procario, M.; Re, V.; Riester, J.L.; Roe, S.; Roff, D.; Rudge, A.; Runolfsson, O.; Russ, J.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trawick, M.; Trischuk, W.; Vittone, E.; Wagner, A.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; White, C.; Zeuner, W.; Ziock, H.; Zoeller, M.

    1999-01-01

    The paper reviews measurements of the radiation hardness of CVD diamond for 24 GeV/c proton irradiation at fluences up to 5 * 10 15 protons/cm 2 . The results not only show radiation damage but also an annealing effect that is dominant at levels around 10 15 protons/cm 2 . A model describing both effects is introduced, enabling a prediction of the distribution curve of the charge signal for other levels

  13. Parameterisation of radiation effects on CVD diamond for proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hartjes, F.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knoepfle, K.T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P.F.; Manfredotti, C.; Marshall, R.D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L.S.; Palmieri, V.G.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Procario, M.; Re, V.; Riester, J.L.; Roe, S.; Roff, D.; Rudge, A.; Runolfsson, O.; Russ, J.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trawick, M.; Trischuk, W.; Vittone, E.; Wagner, A.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; White, C.; Zeuner, W.; Ziock, H.; Zoeller, M

    1999-08-01

    The paper reviews measurements of the radiation hardness of CVD diamond for 24 GeV/c proton irradiation at fluences up to 5{sup *}10{sup 15} protons/cm{sup 2}. The results not only show radiation damage but also an annealing effect that is dominant at levels around 10{sup 15} protons/cm{sup 2}. A model describing both effects is introduced, enabling a prediction of the distribution curve of the charge signal for other levels.

  14. A registry-based follow-up study, comparing the incidence of cardiovascular disease in native Danes and immigrants born in Turkey, Pakistan and the former Yugoslavia: do social inequalities play a role?

    DEFF Research Database (Denmark)

    Hempler, Nana F; Larsen, Finn; Nielsen, Signe S

    2011-01-01

    ), such as employment, income and housing conditions influenced potential differences. METHODS: In this registry-based follow-up study individuals were identified in a large database that included individuals from two major regions in Denmark, corresponding to about 60% of the Danish population. Incident cases of CVD......, differences in CVD and AMI were reduced after adjustment for SES, in particular, among Turks regarding CVD. In women, effects were particularly reduced among Yugoslavians in the case of CVD and in Turks in the case of CVD and AMI after adjustment for SES. CONCLUSIONS: In conclusion, country of birth...

  15. CVD diamonds as thermoluminescent detectors for medical applications

    International Nuclear Information System (INIS)

    Marczewska, B.; Olko, P.; Nesladek, M.; Waligorski, M.P.R.; Kerremans, Y.

    2002-01-01

    Diamond is believed to be a promising material for medical dosimetry due to its tissue equivalence, mechanical and radiation hardness, and lack of solubility in water or in disinfecting agents. A number of diamond samples, obtained under different growth conditions at Limburg University, using the chemical vapour deposition (CVD) technique, was tested as thermoluminescence dosemeters. Their TL glow curve, TL response after doses of gamma rays, fading, and so on were studied at dose levels and for radiation modalities typical for radiotherapy. The investigated CVD diamonds displayed sensitivity comparable with that of MTS-N (Li:Mg,Ti) detectors, signal stability (reproducibility after several readouts) below 10% (1 SD) and no fading was found four days after irradiation. A dedicated CVD diamond plate was grown, cut into 20 detector chips (3x3x0.5 mm) and used for measuring the dose-depth distribution at different depths in a water phantom, for 60 Co and six MV X ray radiotherapy beams. Due to the sensitivity of diamond to ambient light, it was difficult to achieve reproducibility comparable with that of standard LiF detectors. (author)

  16. Nitrogen and hydrogen related infrared absorption in CVD diamond films

    Energy Technology Data Exchange (ETDEWEB)

    Titus, E. [Department of Mechanical Engineering, University of Aveiro, 3810-193 (Portugal)]. E-mail: elby@mec.ua.pt; Ali, N. [Department of Mechanical Engineering, University of Aveiro, 3810-193 (Portugal); Cabral, G. [Department of Mechanical Engineering, University of Aveiro, 3810-193 (Portugal); Madaleno, J.C. [Department of Mechanical Engineering, University of Aveiro, 3810-193 (Portugal); Neto, V.F. [Department of Mechanical Engineering, University of Aveiro, 3810-193 (Portugal); Gracio, J. [Department of Mechanical Engineering, University of Aveiro, 3810-193 (Portugal); Ramesh Babu, P [Materials Ireland, Polymer research Centre, School of Physics, Dublin (Ireland); Sikder, A.K. [Department of Physics, Indian Institute of Technology (IIT), Bombay (India); Okpalugo, T.I. [Northern Ireland Bio-Engineering Centre, NIBEC, University of Ulster (United Kingdom); Misra, D.S. [Department of Physics, Indian Institute of Technology (IIT), Bombay (India)

    2006-09-25

    In this paper, we investigate on the presence of hydrogen and nitrogen related infrared absorptions in chemical vapour deposited (CVD) diamond films. Investigations were carried out in cross sections of diamond windows, deposited using hot filament CVD (HFCVD). The results of Scanning Electron Microscopy (SEM), Fourier Transform Infrared (FTIR) and Raman spectroscopy carried out in a cross section of self-standing diamond sheets are presented. The FTIR spectra showed several features that have not been reported before. In order to confirm the frequency of nitrogen related vibrations, ab-initio calculations were carried out using GAMESS program. The investigations showed the presence of several C-N related peaks in one-phonon (1000-1333 cm{sup -1}). The deconvolution of the spectra in the three-phonon region (2700-3150 cm{sup -1}) also showed a number of vibration modes corresponding to sp {sup m}CH {sub n} phase of carbon. Elastic recoil detection analysis (ERDA) was employed to compare the H content measured using FTIR technique. Using these measurements we point out that the oscillator strength of the different IR modes varies depending upon the structure and H content of CVD diamond sheets.

  17. Thermoluminescent properties of CVD diamond: applications to ionising radiation dosimetry

    International Nuclear Information System (INIS)

    Petitfils, A.

    2007-09-01

    Remarkable properties of synthetic diamond (human soft tissue equivalence, chemical stability, non-toxicity) make this material suitable for medical application as thermoluminescent dosimeter (TLD). This work highlights the interest of this material as radiotherapy TLD. In the first stage of this work, we looked after thermoluminescent (TL) and dosimetric properties of polycrystalline diamond made by Chemically Vapor Deposited (CVD) synthesis. Dosimetric characteristics are satisfactory as TLD for medical application. Luminescence thermal quenching on diamond has been investigated. This phenomenon leads to a decrease of dosimetric TL peak sensitivity when the heating rate increases. The second part of this work analyses the use of synthetic diamond as TLD in radiotherapy. Dose profiles, depth dose distributions and the cartography of an electron beam obtained with our samples are in very good agreement with results from an ionisation chamber. It is clearly shown that CVD) diamond is of interest to check beams of treatment accelerators. The use of these samples in a control of treatment with Intensity Modulated Radiation Therapy underlines good response of synthetic diamond in high dose gradient areas. These results indicate that CVD diamond is a promising material for radiotherapy dosimetry. (author)

  18. Investigation of CVD graphene topography and surface electrical properties

    International Nuclear Information System (INIS)

    Wang, Rui; Pearce, Ruth; Gallop, John; Patel, Trupti; Pollard, Andrew; Hao, Ling; Zhao, Fang; Jackman, Richard; Klein, Norbert; Zurutuza, Amaia

    2016-01-01

    Combining scanning probe microscopy techniques to characterize samples of graphene, a selfsupporting, single atomic layer hexagonal lattice of carbon atoms, provides far more information than a single technique can. Here we focus on graphene grown by chemical vapour deposition (CVD), grown by passing carbon containing gas over heated copper, which catalyses single atomic layer growth of graphene on its surface. To be useful for applications the graphene must be transferred onto other substrates. Following transfer it is important to characterize the CVD graphene. We combine atomic force microscopy (AFM) and scanning Kelvin probe microscopy (SKPM) to reveal several properties of the transferred film. AFM alone provides topographic information, showing ‘wrinkles’ where the transfer provided incomplete substrate attachment. SKPM measures the surface potential indicating regions with different electronic properties for example graphene layer number. By combining AFM and SKPM local defects and impurities can also be observed. Finally, Raman spectroscopy can confirm the structural properties of the graphene films, such as the number of layers and level of disorder, by observing the peaks present. We report example data on a number of CVD samples from different sources. (paper)

  19. Mass production of CNTs using CVD multi-quartz tubes

    Energy Technology Data Exchange (ETDEWEB)

    Yousef, Samy; Mohamed, Alaa [Dept. of Production Engineering and Printing Technology, Akhbar Elyom Academy, Giza (Egypt)

    2016-11-15

    Carbon nanotubes (CNTs) have become the backbone of modern industries, including lightweight and heavy-duty industrial applications. Chemical vapor deposition (CVD) is considered as the most common method used to synthesize high yield CNTs. This work aims to develop the traditional CVD for the mass production of more economical CNTs, meeting the growing CNT demands among consumers by increasing the number of three particular reactors. All reactors housing is connected by small channels to provide the heat exchange possibility between the chambers, thereby decreasing synthesis time and reducing heat losses inside the ceramic body of the furnace. The novel design is simple and cheap with a lower reacting time and heat loss compared with the traditional CVD design. Methane, hydrogen, argon, and catalyzed iron nanoparticles were used as a carbon source and catalyst during the synthesis process. In addition, CNTs were produced using only a single quartz tube for comparison. The produced samples were examined using XRD, TEM, SEM, FTIR, and TGA. The results showed that the yield of CNTs increases by 287 % compared with those synthesized with a single quartz tube. Moreover, the total synthesis time of CNTs decreases by 37 % because of decreased heat leakage.

  20. Estimating cardiovascular disease incidence from prevalence: a spreadsheet based model

    Directory of Open Access Journals (Sweden)

    Xue Feng Hu

    2017-01-01

    Full Text Available Abstract Background Disease incidence and prevalence are both core indicators of population health. Incidence is generally not as readily accessible as prevalence. Cohort studies and electronic health record systems are two major way to estimate disease incidence. The former is time-consuming and expensive; the latter is not available in most developing countries. Alternatively, mathematical models could be used to estimate disease incidence from prevalence. Methods We proposed and validated a method to estimate the age-standardized incidence of cardiovascular disease (CVD, with prevalence data from successive surveys and mortality data from empirical studies. Hallett’s method designed for estimating HIV infections in Africa was modified to estimate the incidence of myocardial infarction (MI in the U.S. population and incidence of heart disease in the Canadian population. Results Model-derived estimates were in close agreement with observed incidence from cohort studies and population surveillance systems. This method correctly captured the trend in incidence given sufficient waves of cross-sectional surveys. The estimated MI declining rate in the U.S. population was in accordance with the literature. This method was superior to closed cohort, in terms of the estimating trend of population cardiovascular disease incidence. Conclusion It is possible to estimate CVD incidence accurately at the population level from cross-sectional prevalence data. This method has the potential to be used for age- and sex- specific incidence estimates, or to be expanded to other chronic conditions.

  1. Incident Cardiovascular Disease Among Adults With Blood Pressure Hg.

    Science.gov (United States)

    Tajeu, Gabriel S; Booth, John N; Colantonio, Lisandro D; Gottesman, Rebecca F; Howard, George; Lackland, Daniel T; O'Brien, Emily C; Oparil, Suzanne; Ravenell, Joseph; Safford, Monika M; Seals, Samantha R; Shimbo, Daichi; Shea, Steven; Spruill, Tanya M; Tanner, Rikki M; Muntner, Paul

    2017-08-29

    Data from before the 2000s indicate that the majority of incident cardiovascular disease (CVD) events occur among US adults with systolic and diastolic blood pressure (SBP/DBP) ≥140/90 mm Hg. Over the past several decades, BP has declined and hypertension control has improved. We estimated the percentage of incident CVD events that occur at SBP/DBP Hg in a pooled analysis of 3 contemporary US cohorts: the REGARDS study (Reasons for Geographic and Racial Differences in Stroke), the MESA (Multi-Ethnic Study of Atherosclerosis), and the JHS (Jackson Heart Study) (n=31 856; REGARDS=21 208; MESA=6779; JHS=3869). Baseline study visits were conducted in 2003 to 2007 for REGARDS, 2000 to 2002 for MESA, and 2000 to 2004 for JHS. BP was measured by trained staff using standardized methods. Antihypertensive medication use was self-reported. The primary outcome was incident CVD, defined by the first occurrence of fatal or nonfatal stroke, nonfatal myocardial infarction, fatal coronary heart disease, or heart failure. Events were adjudicated in each study. Over a mean follow-up of 7.7 years, 2584 participants had incident CVD events. Overall, 63.0% (95% confidence interval [CI], 54.9-71.1) of events occurred in participants with SBP/DBP Hg; 58.4% (95% CI, 47.7-69.2) and 68.1% (95% CI, 60.1-76.0) among those taking and not taking antihypertensive medication, respectively. The majority of events occurred in participants with SBP/DBP Hg among those Hg, 76.6% (95% CI, 75.8-77.5) were eligible for statin treatment, but only 33.2% (95% CI, 32.1-34.3) were taking one, and 19.5% (95% CI, 18.5-20.5) met the SPRINT (Systolic Blood Pressure Intervention Trial) eligibility criteria and may benefit from a SBP target goal of 120 mm Hg. Although higher BP levels are associated with increased CVD risk, in the modern era, the majority of incident CVD events occur in US adults with SBP/DBP Hg. While absolute risk and cost-effectiveness should be considered, additional CVD risk

  2. Dietary Patterns in Relation to Cardiovascular Disease Incidence and Risk Markers in a Middle-Aged British Male Population: Data from the Caerphilly Prospective Study

    NARCIS (Netherlands)

    Mertens, Elly; Markey, Oonagh; Geleijnse, Johanna; Givens, David; Lovegrove, Julie

    2017-01-01

    Dietary behaviour is an important modifiable factor in cardiovascular disease (CVD) prevention. The study aimed to identify dietary patterns (DPs) and explore their association with CVD incidence and risk markers. A follow-up of 1838 middle-aged men, aged 47–67 years recruited into the Caerphilly

  3. The association of bone mineral density measures with incident cardiovascular disease in older men and women: the Health, Aging, and Body Composition Study

    NARCIS (Netherlands)

    Farhat, G.N.; Newman, A.B.; Sutton-Tyrell, K.; Matthews, K.A.; Boudreau, R.; Schwartz, A.; Harris, T.B.; Tylavsky, F.A.; Visser, M.; Cauley, J.A.

    2007-01-01

    Summary: The associations of volumetric and areal bone mineral density (BMD) measures with incident cardiovascular disease (CVD) were studied in a biracial cohort of 2,310 older adults. BMD measures were inversely related to CVD in women and white men, independent of age and shared risk factors for

  4. Nucleation of microwave plasma CVD diamond on molybdenum (Mo) substrate

    International Nuclear Information System (INIS)

    Inderjeet, K.; Ramesh, S.

    2000-01-01

    Molybdenum is a metal, which is gaining increasing significance in industrial applications. The main use of Mo is as all alloying element added in small amounts to steel, irons and non- ferrous alloys in order to enhance the strength, toughness and wear resistance. Mo is also vastly being employed in the automotive and aircraft industries, mainly due to its low coefficient of friction. Diamond, on be other hand, is a unique material for innumerable applications because of its usual combination of physical and chemical properties. Several potential applications can be anticipated for diamond in many sectors including electronics, optics, as protective corrosion resistant coatings, cutting tools, etc. With the enhancement in science and technology, diamond microcrystals and thin films are now being produced from the vapour phase by a variety of chemical vapour deposition (CVD) techniques; such as microwave plasma CVD. With such technology being made available, it is envisage that diamond-coated molybdenum would further enhance the performance and to open up new avenue for Mo in various industries. Therefore, it is the aim of the present work to study the nucleation and growth of diamond particles on Mo surface by employing microwave plasma CVD (MAPCVD). In the present work, diamond deposition was carried out in several stages by varying the deposition distance. The nucleation and growth rate were studied using scanning electron microscopy (SEM). In addition, the existence of diamond was verified by X-ray diffraction (XRD) analysis. It has been found that the nucleation and growth rate of diamond particles were influenced by the deposition height between the substrate and plasma. Under the optimum condition, well defined diamond crystallites distributed homogeneously throughout the surface, could be obtained. Some of the important parameters controlling the deposition and growth of diamond particles on Mo surface are discussed. (author)

  5. Commissioning and first operation of the pCVD diamond ATLAS Beam Conditions Monitor

    CERN Document Server

    Dobos, D

    2009-01-01

    The main aim of the ATLAS Beam Conditions Monitor is to protect the ATLAS Inner Detector silicon trackers from high radiation doses caused by LHC beam incidents, e.g. magnet failures. The BCM uses in total 16 1x1 cm2 500 μm thick polycrystalline chemical vapor deposition (pCVD) diamond sensors. They are arranged in 8 positions around the ATLAS LHC interaction point. Time difference measurements with sub nanosecond resolution are performed to distinguish between particles from a collision and spray particles from a beam incident. An abundance of the latter leads the BCM to provoke an abort of the LHC beam. A FPGA based readout system with a sampling rate of 2.56 GHz performs the online data analysis and interfaces the results to ATLAS and the beam abort system. The BCM diamond sensors, the detector modules and their readout system are described. Results of the operation with the first LHC beams are reported and results of commissioning and timing measurements (e.g. with cosmic muons) in preparation for first ...

  6. Stress analysis of CVD diamond window for ECH system

    International Nuclear Information System (INIS)

    Takahashi, Koji

    2001-03-01

    The stress analysis of a chemical vapor deposition (CVD) diamond window for Electron Cyclotron Heating and Current Drive (ECH/ECCD) system of fusion reactors is described. It was found that the real size diamond window (φ aper =70mm, t=2.25mm) withstood 14.5 atm. (1.45 MPa). The calculation results of the diamond window by ABAQUS code agree well with the results of the pressure test. The design parameters of the torus diamond window for a vacuum and a safety barrier were also obtained. (author)

  7. CVD diamond sensor for UV-photon detection

    CERN Document Server

    Periale, L; Gervino, G; Lamarina, A M; Palmisano, C; Periale, R; Picchi, P

    2012-01-01

    A new generation of UV photosensors, based on single crystal Chemical Vapour Deposition (CVD) diamonds to work optically coupled with large volume two-phase liquid-Ar (LAr) or liquid-Xe (LXe) detectors nowadays under design for the next generation of WIMPs experiments, is under development. Preliminary tests and first calibrations show these devices can have better performance than the existing UV sensitive detectors (higher photosensitivity and better signal-to-noise ratio). I-V characteristics, dark current measurements, linearity response to X-ray irradiation, and alpha-particle energy resolution are reported and discussed. (C) 2011 Elsevier B.V. All rights reserved.

  8. CVD Graphene/Ni Interface Evolution in Sulfuric Electrolyte

    DEFF Research Database (Denmark)

    Yivlialin, Rossella; Bussetti, Gianlorenzo; Duò, Lamberto

    2018-01-01

    Systems comprising single and multilayer graphene deposited on metals and immersed in acid environments have been investigated, with the aim of elucidating the mechanisms involved, for instance, in hydrogen production or metal protection from corrosion. In this work, a relevant system, namely...... chemical vapor deposited (CVD) multilayer graphene/Ni (MLGr/Ni), is studied when immersed in a diluted sulfuric electrolyte. The MLGr/Ni electrochemical and morphological properties are studied in situ and interpreted in light of the highly oriented pyrolytic graphite (HOPG) electrode behavior, when...... immersed in the same electrolyte. Following this interpretative framework, the dominant role of the Ni substrate in hydrogen production is clarified....

  9. Effects of Light Intensity Activity on CVD Risk Factors: A Systematic Review of Intervention Studies

    Directory of Open Access Journals (Sweden)

    Romeo B. Batacan

    2015-01-01

    Full Text Available The effects of light intensity physical activity (LIPA on cardiovascular disease (CVD risk factors remain to be established. This review summarizes the effects of LIPA on CVD risk factors and CVD-related markers in adults. A systematic search of four electronic databases (PubMed, Academic Search Complete, SPORTDiscus, and CINAHL examining LIPA and CVD risk factors (body composition, blood pressure, glucose, insulin, glycosylated hemoglobin, and lipid profile and CVD-related markers (maximal oxygen uptake, heart rate, C-reactive protein, interleukin-6, tumor necrosis factor-alpha, and tumor necrosis factor receptors 1 and 2 published between 1970 and 2015 was performed on 15 March 2015. A total of 33 intervention studies examining the effect of LIPA on CVD risk factors and markers were included in this review. Results indicated that LIPA did not improve CVD risk factors and CVD-related markers in healthy individuals. LIPA was found to improve systolic and diastolic blood pressure in physically inactive populations with a medical condition. Reviewed studies show little support for the role of LIPA to reduce CVD risk factors. Many of the included studies were of low to fair study quality and used low doses of LIPA. Further studies are needed to establish the value of LIPA in reducing CVD risk.

  10. Depression and Anxiety Screens as Predictors of 8-Year Incidence of Myocardial Infarction and Stroke in Primary Care Patients.

    Science.gov (United States)

    Stewart, Jesse C; Hawkins, Misty A W; Khambaty, Tasneem; Perkins, Anthony J; Callahan, Christopher M

    2016-06-01

    Because depression and anxiety are typically studied in isolation, our purpose was to examine the relative importance of these overlapping emotional factors in predicting incident cardiovascular disease (CVD). We examined depression and anxiety screens, and their individual items, as predictors of incident hard CVD events, myocardial infarction, and stroke for 8 years in a diverse sample of 2041 older primary care patients initially free of CVD. At baseline, participants completed self-report depression and anxiety screens. Data regarding CVD events were obtained from an electronic medical record system and the Centers for Medicare and Medicaid Services analytic files. During follow-up, 683 (33%) experienced a CVD event. Cox proportional hazards models-adjusted for demographic and CVD risk factors-revealed that a positive anxiety screen, but not a positive depression screen, was associated with an increased risk of a hard CVD event in separate models (Years 0-3: anxiety hazard ratio [HR] = 1.54, 95% confidence interval [CI] = 1.21-1.96, p anxiety HR = 0.99, CI = 0.81-1.21), p = .93; depression HR = 1.10, CI = 0.88-1.36, p = .41), as well as when entered into the same model (Years 0-3: anxiety HR = 1.53, CI = 1.20-1.95, p anxiety HR = 0.99, CI = 0.80-1.21, p = .99; depression HR = 1.03, CI = 0.82-1.29, p = .82). Analyses examining individual items and secondary outcomes showed that the anxiety-CVD association was largely driven by the feeling anxious item and the myocardial infarction outcome. Anxiety, especially feeling anxious, is a unique risk factor for CVD events in older adults, independent of conventional risk factors and depression. Anxiety deserves increased attention as a potential factor relevant to CVD risk stratification and a potential target of CVD primary prevention efforts.

  11. Impact of traditional and novel risk factors on the relationship between socioeconomic status and incident cardiovascular events.

    Science.gov (United States)

    Albert, Michelle A; Glynn, Robert J; Buring, Julie; Ridker, Paul M

    2006-12-12

    Persons of lower socioeconomic status have greater cardiovascular risk than those of higher socioeconomic status. However, the mechanism through which socioeconomic status affects cardiovascular disease (CVD) is uncertain. Virtually no data are available that examine the prospective association between novel inflammatory and hemostatic CVD risk indicators, socioeconomic status, and incident CVD events. We assessed the relationship between 2 indicators of socioeconomic status (education and income), traditional and novel CVD risk factors (high sensitivity C-reactive protein, soluble intercellular adhesion molecule-1, fibrinogen, and homocysteine), and incident CVD events among 22,688 apparently healthy female health professionals participating in the Women's Health Study. These women were followed up for 10 years for the development of myocardial infarction, ischemic stroke, coronary revascularization, and cardiovascular death. More educated women were less likely to be smokers; had a lower prevalence of hypertension, diabetes, and obesity; and were more likely to participate in vigorous physical activity than less educated women. At baseline, median total cholesterol, low-density lipoprotein, triglyceride, C-reactive protein, intercellular adhesion molecule-1, fibrinogen, and homocysteine levels for women in 5 categories of education (master's degree, and a doctoral degree) and 6 categories of income [ or = 100,000 dollars) decreased progressively with increasing education or income levels (all Prisk of incident CVD events decreased with increasing education (1.0, 0.7, 0.5, 0.4, and 0.5; P for trend risk factors on the relationship between education/income and CVD events, the relative hazard of incident CVD associated with a 1-category-higher level of education changed from 0.79 in age- and race-adjusted analysis to 0.89 in fully adjusted analysis. The 11% lower risk per 1 category of education remained significant (P for trend=0.006), suggesting that controlling

  12. Wheelchair incidents

    NARCIS (Netherlands)

    Drongelen AW van; Roszek B; Hilbers-Modderman ESM; Kallewaard M; Wassenaar C; LGM

    2002-01-01

    This RIVM study was performed to gain insight into wheelchair-related incidents with powered and manual wheelchairs reported to the USA FDA, the British MDA and the Dutch Center for Quality and Usability Research of Technical Aids (KBOH). The data in the databases do not indicate that incidents with

  13. CVD-graphene growth on different polycrystalline transition metals

    Directory of Open Access Journals (Sweden)

    M. P. Lavin-Lopez

    2017-01-01

    Full Text Available The chemical vapor deposition (CVD graphene growth on two polycrystalline transition metals (Ni and Cu was investigated in detail using Raman spectroscopy and optical microscopy as a way to synthesize graphene of the highest quality (i.e. uniform growth of monolayer graphene, which is considered a key issue for electronic devices. Key CVD process parameters (reaction temperature, CH4/H2flow rate ratio, total flow of gases (CH4+H2, reaction time were optimized for both metals in order to obtain the highest graphene uniformity and quality. The conclusions previously reported in literature about the performance of low and high carbon solubility metals in the synthesis of graphene and their associated reaction mechanisms, i.e. surface depositionand precipitation on cooling, respectively, was not corroborated by the results obtained in this work. Under the optimal reaction conditions, a large percentage of monolayer graphene was obtained over the Ni foil since the carbon saturation was not complete, allowing carbon atoms to be stored in the bulk metal, which could diffuse forming high quality monolayer graphene at the surface. However, under the optimal reaction conditions, the formation of a non-uniform mixture of few layers and multilayer graphene on the Cu foil was related to the presence of an excess of active carbon atoms on the Cu surface.

  14. Oxide Dispersion Strengthened Iron Aluminide by CVD Coated Powders

    Energy Technology Data Exchange (ETDEWEB)

    Asit Biswas Andrew J. Sherman

    2006-09-25

    This I &I Category2 program developed chemical vapor deposition (CVD) of iron, aluminum and aluminum oxide coated iron powders and the availability of high temperature oxidation, corrosion and erosion resistant coating for future power generation equipment and can be used for retrofitting existing fossil-fired power plant equipment. This coating will provide enhanced life and performance of Coal-Fired Boilers components such as fire side corrosion on the outer diameter (OD) of the water wall and superheater tubing as well as on the inner diameter (ID) and OD of larger diameter headers. The program also developed a manufacturing route for readily available thermal spray powders for iron aluminide coating and fabrication of net shape component by powder metallurgy route using this CVD coated powders. This coating can also be applid on jet engine compressor blade and housing, industrial heat treating furnace fixtures, magnetic electronic parts, heating element, piping and tubing for fossil energy application and automotive application, chemical processing equipment , heat exchanger, and structural member of aircraft. The program also resulted in developing a new fabrication route of thermal spray coating and oxide dispersion strengthened (ODS) iron aluminide composites enabling more precise control over material microstructures.

  15. A study of the thermoluminescent properties of CVD diamond detectors

    International Nuclear Information System (INIS)

    Marczewska, B.; Bilski, P.; Olko, P.; Rebisz, M.; Nesladek, M.; Waligorski, M.P.R.

    2002-01-01

    A batch of 20 diamond detectors obtained by the chemical vapour deposition (CVD) method at the Institute for Materials Research at the Limburg University, Belgium, was investigated with respect to their thermoluminescent (TL) properties. The investigated detectors demonstrate TL sensitivity similar to that of the standard LiF:Mg, Ti (MTS) thermoluminescent detectors, lack of fading after two weeks from irradiation and apparent linearity of dose response. In spite of the persistent fluctuation of individual detector sensitivity observed in this batch, a new annealing procedure improved the stability of the TL signal. It has been concluded that 1 h annealing at 350 C assures the highest reproducibility for this set of detectors. A 30% discrepancy of the value of the TL signal between individual detectors from the batch may be caused by non-uniform distribution of dopants in the volume of the CVD diamond. A prototype of a planar TL reader equipped with a CCD camera was employed in this investigation. (Abstract Copyright [2002], Wiley Periodicals, Inc.)

  16. Thermoluminescence in CVD diamond films: application to actinometric dosimetry

    International Nuclear Information System (INIS)

    Barboza-Flores, M.; Melendrez, R.; Chernov, V.; Castaneda, B.; Pedroza-Montero, M.; Gan, B.; Ahn, J.; Zhang, Q.; Yoon, S.F.

    2002-01-01

    Diamond is considered a tissue-equivalent material since its atomic number (Z=6) is close to the effective atomic number of biological tissue (Z=7.42). Such a situation makes it suitable for radiation detection purposes in medical applications. In the present work the analysis is reported of the thermoluminescence (TL) and dosimetric features of chemically vapour deposited (CVD) diamond film samples subjected to ultraviolet (UV) irradiation in the actinometric region. The TL glow curve shows peaks at 120, 220, 320 and 370 deg. C. The 120 and 370 deg. C peaks are too weak and the first one fades away in a few seconds after exposure. The overall room temperature fading shows a 50% TL decay 30 min after exposure. The 320 deg. C glow peak is considered to be the most adequate for dosimetric applications due to its low fading and linear TL behaviour as a function of UV dose in the 180-260 nm range. The TL excitation spectrum presents a broad band with at least two overlapped components around 205 and 220 nm. The results indicate that the TL behaviour of CVD diamond film can be a good alternative to the currently available dosemeter and detector in the actinometric region as well as in clinical and medical applications. (author)

  17. VOx effectively doping CVD-graphene for transparent conductive films

    Science.gov (United States)

    Ji, Qinghua; Shi, Liangjing; Zhang, Qinghong; Wang, Weiqi; Zheng, Huifeng; Zhang, Yuzhi; Liu, Yangqiao; Sun, Jing

    2016-11-01

    Chemical vapor deposition(CVD)-synthesized graphene is potentially an alternative for tin-doped indium oxide (ITO) transparent conductive films (TCFs), however its sheet resistance is still too high to meet many demands. Vanadium oxide has been widely applied as smart window materials, however, no study has been reported to use it as dopant to improve the conductivity of graphene TCFs. In this study, we firstly reported that VOx doping can effectively lower the sheet resistance of CVD-graphene films while keeping its good optical properties, whose transmittance is as high as 86-90%. The optimized VOx-doped graphene exhibits a sheet resistance as low as 176 Ω/□, which decreases by 56% compared to the undoped graphene films. The doping process is convenient, stable, economical and easy to operate. What is more, VOx can effectively increase the work function(WF) of the film, making it more appropriate for use in solar cells. The evolution of the VOx species annealed at different temperatures below 400 °C has been detailed studied for the first time, based on which the doping mechanism is proposed. The prepared VOx doped graphene is expected to be a promising candidate for transparent conductive film purposes.

  18. Management of Hypertension and Other CVD Risk Factors in Egypt

    Directory of Open Access Journals (Sweden)

    Mostafa A. Abolfotouh

    2011-01-01

    Full Text Available Aim. To assess the knowledge and practice of PHC physicians toward the detection and management of hypertension (HTN and other CVD risk factors. Methods. A cross-sectional study of all primary health care physicians of the FHU of three rural districts of Egypt was conducted. Each physician was subjected to a prevalidated interview questionnaire on the WHO-CVD risk management package for low and medium resources, and a checklist of observation of daily practices. Results. Hypertension was a priority problem in about two-thirds (62.9% of physicians, yet only 19% have guidelines for HTN patients. Clinical history recording system for HNT was available for 50% of physicians. Levels of knowledge varied with regard to definition of HTN (61.3%, fair, procedures for BP measurement (43.5%, poor, indications for referral (43.5%, poor, patient counseling (61.3%, fair, patient treatment (59.8%, fair. Availability of clinical history recording system for HNT was a significant predictor for physician's level of knowledge (P=0.001. Overall level of practice was fair (68.5%. Conclusion. PHC physicians have unsatisfactory knowledge and practice on hypertension. There is a need of more continuing medical education. Local and international manuals, workshops, and seminars on how to make use of these guidelines would improve doctors' performance.

  19. Response of CVD diamond detectors to alpha radiation

    Energy Technology Data Exchange (ETDEWEB)

    Souw, E.-K. [Brookhaven National Lab., Upton, NY (United States); Meilunas, R.J. [Northrop-Grumman Corporation, Bethpage, NY 11714-3582 (United States)

    1997-11-21

    This article describes some results from an experiment with CVD diamond films used as {alpha} particle detectors. It demonstrates that bulk polarization can be effectively stopped within a reasonable time interval. This will enable detector calibration and quantitative measurement. A possible mechanism for the observed polarization quenching is discussed. It involves two types of carrier traps and a tentative band-gap model derived from the results of photoconductive current measurements. The experiment was set up mainly to investigate {alpha} detection properties of polycrystalline diamond films grown by the technique of microwave plasma enhanced chemical vapor deposition. For comparison, two commercially purchased diamond wafers were also investigated, i.e., one grown by the DC arc jet method, and the other, a type-IIa natural diamond wafer (not preselected). The best response to {alpha} particles was obtained using diamond thin-films grown by the microwave PECVD method, followed by the type-IIa natural diamond, and finally, the CVD diamond grown by the DC arc jet technique. (orig.). 43 refs.

  20. Prevalence of undiagnosed cardiovascular risk factors and 10-year CVD risk in male steel industry workers.

    Science.gov (United States)

    Gray, Benjamin J; Bracken, Richard M; Turner, Daniel; Morgan, Kerry; Mellalieu, Stephen D; Thomas, Michael; Williams, Sally P; Williams, Meurig; Rice, Sam; Stephens, Jeffrey W

    2014-05-01

    To assess the prevalence of undiagnosed cardiovascular disease (CVD) in a cohort of male steelworkers in South Wales, UK. Male steel industry workers (n = 221) with no prior diagnosis of CVD or diabetes accepted a CVD risk assessment within the work environment. Demographic, anthropometric, family, and medical histories were all recorded and capillary blood samples obtained. The 10-year CVD risk was predicted using the QRISK2-2012 algorithm. Up to 81.5% of workers were either overweight or obese. More than 20% of workers were found to have diastolic hypertension, high total cholesterol, and/or a total cholesterol/high-density lipoprotein ratio of six or more. Over one quarter of workers assessed had an increased 10-year CVD risk. Despite a physically demanding occupation, risk assessment in the workplace uncovered significant occult factors in CVD risk in a sample of male heavy industry workers.

  1. Thermal Analysis of Cold Vacuum Drying (CVD) of Spent Nuclear Fuel (SNF)

    International Nuclear Information System (INIS)

    PIEPHO, M.G.

    2000-01-01

    The thermal analysis examined transient thermal and chemical behavior of the Multi-Canister Overpack (MCO) container for a broad range of cases that represent the Cold Vacuum Drying (CVD) processes. The cases were defined to consider both normal and off-normal operations at the CVD Facility for an MCO with N Reactor spent fuel. This analysis provides the basis for the MCO thermal behavior at the CVD Facility in support of the safety basis documentation

  2. Hydroxychloroquine Use Is Associated With Decreased Incident Cardiovascular Events in Rheumatoid Arthritis Patients.

    Science.gov (United States)

    Sharma, Tarun S; Wasko, Mary Chester M; Tang, Xiaoqin; Vedamurthy, Deepak; Yan, Xiaowei; Cote, Jonida; Bili, Androniki

    2016-01-04

    Cardiovascular disease (CVD) is the leading cause of death in rheumatoid arthritis (RA) patients. This study is the first to report the association of hydroxychloroquine (an antirheumatic medication that has been associated with decreased risk of diabetes, a less atherogenic lipid profile, and antithrombotic properties) with CVD in RA. A retrospective incident RA cohort from January 1, 2001, to October 31, 2013, excluding patients with CVD prior to RA diagnosis, was constructed. Patients were categorized as hydroxychloroquine users versus nonusers and were allowed to contribute time to either group according to hydroxychloroquine exposure. The primary outcome was adjudicated incident CVD defined as a composite of coronary artery disease, stroke, transient ischemic attack, sudden cardiac death, and peripheral artery disease with arterial revascularization procedure. The secondary outcome was a composite of incident coronary artery disease, stroke, and transient ischemic attack. Cox time-varying regression models were used to estimate the association between hydroxychloroquine exposure and development of CVD, after adjusting for propensity score and relevant confounders, including demographics, CVD-related comorbidities, RA severity, and activity indicators and medications. We included 1266 RA patients, 547 hydroxychloroquine users, and 719 nonusers. During the observation period, 102 CVD events occurred, 3 in hydroxychloroquine users and 99 in nonusers. The fully adjusted Cox model showed a hazard ratio of 0.28 (95% CI 0.12-0.63, P=0.002) for incident CVD and 0.30 (95% CI 0.13-0.68, P=0.004) for incident composite coronary artery disease, stroke, and transient ischemic attack for hydroxychloroquine users versus nonusers, respectively. In this hypothesis-generating study, hydroxychloroquine use was associated with a 72% decrease in the risk of incident CVD in RA patients. If these preliminary results are confirmed in larger studies, our findings may be used as a

  3. A measure of the interfacial shear strength between SiC(CVD)/B(CVD) filament--aluminum matrix by fragmentation method

    International Nuclear Information System (INIS)

    Jiang, Y.Q.; Chen, X.J.; Yang, D.M.; Fei, X.; Pan, J.

    1993-01-01

    The tensile specimens used are of dog-bone shape and consist of single axial SiC (CVD) /B (CVD) filament processed by CVD and embedded in a LD-2 aluminum alloy. Model composite specimens have been fabricated by a high pressure squeeze casting technique. This paper describes the application of an Acoustic Emission Technique for locating the position of fiber breaks and thus determining the length distribution of fiber fragments resulting when a composite specimen containing a single fiber is loaded to failure. The critical lengths (minimal lengths) are checked by Corrosion Method

  4. Prevalence, incidence and mortality from cardiovascular disease in patients with pooled and specific severe mental illness: a large-scale meta-analysis of 3,211,768 patients and 113,383,368 controls.

    Science.gov (United States)

    Correll, Christoph U; Solmi, Marco; Veronese, Nicola; Bortolato, Beatrice; Rosson, Stella; Santonastaso, Paolo; Thapa-Chhetri, Nita; Fornaro, Michele; Gallicchio, Davide; Collantoni, Enrico; Pigato, Giorgio; Favaro, Angela; Monaco, Francesco; Kohler, Cristiano; Vancampfort, Davy; Ward, Philip B; Gaughran, Fiona; Carvalho, André F; Stubbs, Brendon

    2017-06-01

    People with severe mental illness (SMI) - schizophrenia, bipolar disorder and major depressive disorder - appear at risk for cardiovascular disease (CVD), but a comprehensive meta-analysis is lacking. We conducted a large-scale meta-analysis assessing the prevalence and incidence of CVD; coronary heart disease; stroke, transient ischemic attack or cerebrovascular disease; congestive heart failure; peripheral vascular disease; and CVD-related death in SMI patients (N=3,211,768) versus controls (N=113,383,368) (92 studies). The pooled CVD prevalence in SMI patients (mean age 50 years) was 9.9% (95% CI: 7.4-13.3). Adjusting for a median of seven confounders, patients had significantly higher odds of CVD versus controls in cross-sectional studies (odds ratio, OR=1.53, 95% CI: 1.27-1.83; 11 studies), and higher odds of coronary heart disease (OR=1.51, 95% CI: 1.47-1.55) and cerebrovascular disease (OR=1.42, 95% CI: 1.21-1.66). People with major depressive disorder were at increased risk for coronary heart disease, while those with schizophrenia were at increased risk for coronary heart disease, cerebrovascular disease and congestive heart failure. Cumulative CVD incidence in SMI patients was 3.6% (95% CI: 2.7-5.3) during a median follow-up of 8.4 years (range 1.8-30.0). Adjusting for a median of six confounders, SMI patients had significantly higher CVD incidence than controls in longitudinal studies (hazard ratio, HR=1.78, 95% CI: 1.60-1.98; 31 studies). The incidence was also higher for coronary heart disease (HR=1.54, 95% CI: 1.30-1.82), cerebrovascular disease (HR=1.64, 95% CI: 1.26-2.14), congestive heart failure (HR=2.10, 95% CI: 1.64-2.70), and CVD-related death (HR=1.85, 95% CI: 1.53-2.24). People with major depressive disorder, bipolar disorder and schizophrenia were all at increased risk of CVD-related death versus controls. CVD incidence increased with antipsychotic use (p=0.008), higher body mass index (p=0.008) and higher baseline CVD prevalence (p=0.03) in

  5. The incidence and economic burden of injuries in Jiangxi, China.

    Science.gov (United States)

    Fang, X; Zeng, G; Linnan, H W; Jing, R; Zhu, X; Corso, P; Liu, P; Linnan, M

    2016-09-01

    This study estimated the incidence, direct medical and non-medical costs, and productivity losses due to morbidity and mortality across multiple strata for injuries that occurred in Jiangxi, China. Cross-sectional study. Data came from the Jiangxi injury survey, a provincially-representative, population-based sample of 100,010 households. The major economic costs of injuries were divided into direct costs and indirect costs. Direct costs encompass medical costs and direct non-medical costs. Indirect costs refer to the productivity losses due to injury-related morbidity and mortality. In 2005, about one of 18 residents in Jiangxi, China, experienced an injury. Overall, fall, animal bite, and road traffic crash (RTC) injuries accounted for more than 66% of all injuries, while fall, RTC, drowning, and self-harm injuries accounted for 80% of fatal injuries. Average cost per case for a fatal injury was 163,389 RMB ($20,171) for lost productivity and 2800 RMB ($346) in direct medical & non-medical costs. A non-fatal injury resulting in hospitalisation or permanent disability on average caused 5221 RMB ($643) in direct costs and 18,437 RMB ($2276) in lost productivity and, an additional loss of three school days. A non-hospitalised non-fatal injury on average caused 303 ($37) RMB in direct costs and 491 RMB ($61) in lost productivity and, an additional loss of 0.5 school days. The unequivocal evidence of the substantial health and financial burden of injuries indicates to Chinese policy makers that more research and efforts are needed to find efficacious and cost-effective interventions targeting injury. Copyright © 2016 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  6. Studies of mono-crystalline CVD diamond pixel detectors

    CERN Document Server

    Bartz, E; Atramentov, O; Yang, Z; Hall-Wilton, R; Schnetzer, S; Patel, R; Bugg, W; Hebda, P; Halyo, V; Hunt, A; Marlow, D; Steininger, H; Ryjov, V; Hits, D; Spanier, S; Pernicka, M; Johns, W; Doroshenko, J; Hollingsworth, M; Harrop, B; Farrow, C; Stone, R

    2011-01-01

    The Pixel Luminosity Telescope (PLT) is a dedicated luminosity monitor, presently under construction, for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC). It measures the particle flux in several three layered pixel diamond detectors that are aligned precisely with respect to each other and the beam direction. At a lower rate it also performs particle track position measurements. The PLTs mono-crystalline CVD diamonds are bump-bonded to the same readout chip used in the silicon pixel system in CMS. Mono-crystalline diamond detectors have many attributes that make them desirable for use in charged particle tracking in radiation hostile environments such as the LHC. In order to further characterize the applicability of diamond technology to charged particle tracking we performed several tests with particle beams that included a measurement of the intrinsic spatial resolution with a high resolution beam telescope. Published by Elsevier B.V.

  7. Oxidation kinetics of CVD silicon carbide and silicon nitride

    Science.gov (United States)

    Fox, Dennis S.

    1992-01-01

    The long-term oxidation behavior of pure, monolithic CVD SiC and Si3N4 is studied, and the isothermal oxidation kinetics of these two materials are obtained for the case of 100 hrs at 1200-1500 C in flowing oxygen. Estimates are made of lifetimes at the various temperatures investigated. Parabolic rate constants for SiC are within an order of magnitude of shorter exposure time values reported in the literature. The resulting silica scales are in the form of cristobalite, with cracks visible after exposure. The oxidation protection afforded by silica for these materials is adequate for long service times under isothermal conditions in 1-atm dry oxygen.

  8. Studies of mono-crystalline CVD diamond pixel detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bugg, W. [University of Tennessee, Knoxville (United States); Hollingsworth, M., E-mail: mhollin3@utk.edu [University of Tennessee, Knoxville (United States); Spanier, S.; Yang, Z. [University of Tennessee, Knoxville (United States); Bartz, E.; Doroshenko, J.; Hits, D.; Schnetzer, S.; Stone, R.; Atramentov, O.; Patel, R.; Barker, A. [Rutgers University, Piscataway (United States); Hall-Wilton, R.; Ryjov, V.; Farrow, C. [CERN, Geneva (Switzerland); Pernicka, M.; Steininger, H. [HEPHY, Vienna (Austria); Johns, W. [Vanderbilt University, Nashville (United States); Halyo, V.; Harrop, B. [Princeton University, Princeton (United States); and others

    2011-09-11

    The Pixel Luminosity Telescope (PLT) is a dedicated luminosity monitor, presently under construction, for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC). It measures the particle flux in several three layered pixel diamond detectors that are aligned precisely with respect to each other and the beam direction. At a lower rate it also performs particle track position measurements. The PLT's mono-crystalline CVD diamonds are bump-bonded to the same readout chip used in the silicon pixel system in CMS. Mono-crystalline diamond detectors have many attributes that make them desirable for use in charged particle tracking in radiation hostile environments such as the LHC. In order to further characterize the applicability of diamond technology to charged particle tracking we performed several tests with particle beams that included a measurement of the intrinsic spatial resolution with a high resolution beam telescope.

  9. Dimensionless Numbers Expressed in Terms of Common CVD Process Parameters

    Science.gov (United States)

    Kuczmarski, Maria A.

    1999-01-01

    A variety of dimensionless numbers related to momentum and heat transfer are useful in Chemical Vapor Deposition (CVD) analysis. These numbers are not traditionally calculated by directly using reactor operating parameters, such as temperature and pressure. In this paper, these numbers have been expressed in a form that explicitly shows their dependence upon the carrier gas, reactor geometry, and reactor operation conditions. These expressions were derived for both monatomic and diatomic gases using estimation techniques for viscosity, thermal conductivity, and heat capacity. Values calculated from these expressions compared well to previously published values. These expressions provide a relatively quick method for predicting changes in the flow patterns resulting from changes in the reactor operating conditions.

  10. Tests of Hercules/Ultramet CVD coatings in hot hydrogen

    International Nuclear Information System (INIS)

    Vanier, P.E.; Barletta, R.E.; Svandrlik, J.; Adams, J.

    1992-01-01

    The effort by Hercules and Ultramet to produce CVD NbC coatings, which protect carbon-carbon substrates from hot hydrogen, has had some success but with some limitations. The coatings increase the survival time at atmospheric pressure and low flow rate of hydrogen by about a factor of 40 over uncoated graphite at 3000 K. However, the grain structure is not stable at these temperatures, and after about 10--20 minutes, the coating is subject to rapid degradation by spalling in visible chunks. Further experiments would have to be performed to determine the effects of higher pressures and flow rates, for it is not clear how these factors would affect the survival time, considering that one of the main failure mechanisms is independent of the atmosphere

  11. Polycrystalline CVD diamond device level modeling for particle detection applications

    Science.gov (United States)

    Morozzi, A.; Passeri, D.; Kanxheri, K.; Servoli, L.; Lagomarsino, S.; Sciortino, S.

    2016-12-01

    Diamond is a promising material whose excellent physical properties foster its use for radiation detection applications, in particular in those hostile operating environments where the silicon-based detectors behavior is limited due to the high radiation fluence. Within this framework, the application of Technology Computer Aided Design (TCAD) simulation tools is highly envisaged for the study, the optimization and the predictive analysis of sensing devices. Since the novelty of using diamond in electronics, this material is not included in the library of commercial, state-of-the-art TCAD software tools. In this work, we propose the development, the application and the validation of numerical models to simulate the electrical behavior of polycrystalline (pc)CVD diamond conceived for diamond sensors for particle detection. The model focuses on the characterization of a physically-based pcCVD diamond bandgap taking into account deep-level defects acting as recombination centers and/or trap states. While a definite picture of the polycrystalline diamond band-gap is still debated, the effect of the main parameters (e.g. trap densities, capture cross-sections, etc.) can be deeply investigated thanks to the simulated approach. The charge collection efficiency due to β -particle irradiation of diamond materials provided by different vendors and with different electrode configurations has been selected as figure of merit for the model validation. The good agreement between measurements and simulation findings, keeping the traps density as the only one fitting parameter, assesses the suitability of the TCAD modeling approach as a predictive tool for the design and the optimization of diamond-based radiation detectors.

  12. CVD diamond Brewster window: feasibility study by FEM analyses

    Directory of Open Access Journals (Sweden)

    Vaccaro A.

    2012-09-01

    Full Text Available Chemical vapor deposition (CVD diamond windows are a crucial component in heating and current drive (H&CD applications. In order to minimize the amount of reflected power from the diamond disc, its thickness must match the desired beam wavelength, thus proper targeting of the plasma requires movable beam reflectors. This is the case, for instance, of the ITER electron cyclotron H&CD system. However, looking at DEMO, the higher heat loads and neutron fluxes could make the use of movable parts close to the plasma difficult. The issue might be solved by using gyrotrons able to tune the beam frequency to the desired resonance, but this concept requires transmission windows that work in a given frequency range, such as the Brewster window. It consists of a CVD diamond disc brazed to two copper cuffs at the Brewster angle. The brazing process is carried out at about 800°C and then the temperature is decreased down to room temperature. Diamond and copper have very different thermal expansion coefficients, therefore high stresses build up during the cool down phase that might lead to failure of the disc. Considering also the complex geometry of the window with the skewed position of the disc, analyses are required in the first place to check its feasibility. The cool down phase was simulated by FEM structural analyses for several geometric and constraint configurations of the window. A study of indirect cooling of the window by water was also performed considering a HE11 mode beam. The results are here reported.

  13. Polycrystalline CVD diamond device level modeling for particle detection applications

    International Nuclear Information System (INIS)

    Morozzi, A.; Passeri, D.; Kanxheri, K.; Servoli, L.; Lagomarsino, S.; Sciortino, S.

    2016-01-01

    Diamond is a promising material whose excellent physical properties foster its use for radiation detection applications, in particular in those hostile operating environments where the silicon-based detectors behavior is limited due to the high radiation fluence. Within this framework, the application of Technology Computer Aided Design (TCAD) simulation tools is highly envisaged for the study, the optimization and the predictive analysis of sensing devices. Since the novelty of using diamond in electronics, this material is not included in the library of commercial, state-of-the-art TCAD software tools. In this work, we propose the development, the application and the validation of numerical models to simulate the electrical behavior of polycrystalline (pc)CVD diamond conceived for diamond sensors for particle detection. The model focuses on the characterization of a physically-based pcCVD diamond bandgap taking into account deep-level defects acting as recombination centers and/or trap states. While a definite picture of the polycrystalline diamond band-gap is still debated, the effect of the main parameters (e.g. trap densities, capture cross-sections, etc.) can be deeply investigated thanks to the simulated approach. The charge collection efficiency due to β -particle irradiation of diamond materials provided by different vendors and with different electrode configurations has been selected as figure of merit for the model validation. The good agreement between measurements and simulation findings, keeping the traps density as the only one fitting parameter, assesses the suitability of the TCAD modeling approach as a predictive tool for the design and the optimization of diamond-based radiation detectors.

  14. Organic solar cells using CVD-grown graphene electrodes

    International Nuclear Information System (INIS)

    Kim, Hobeom; Han, Tae-Hee; Lim, Kyung-Geun; Lee, Tae-Woo; Bae, Sang-Hoon; Ahn, Jong-Hyun

    2014-01-01

    We report on the development of flexible organic solar cells (OSCs) incorporating graphene sheets synthesized by chemical vapor deposition (CVD) as transparent conducting electrodes on polyethylene terephthalate (PET) substrates. A key barrier that must be overcome for the successful fabrication of OSCs with graphene electrodes is the poor-film properties of water-based poly(3,4-ethylenedioxythiphene):poly(styrenesulfonate) (PEDOT:PSS) when coated onto hydrophobic graphene surfaces. To form a uniform PEDOT:PSS film on a graphene surface, we added perfluorinated ionomers (PFI) to pristine PEDOT:PSS to create ‘GraHEL’, which we then successfully spin coated onto the graphene surface. We systematically investigated the effect of number of layers in layer-by-layer stacked graphene anode of an OSC on the performance parameters including the open-circuit voltage (V oc ), short-circuit current (J sc ), and fill factor (FF). As the number of graphene layers increased, the FF tended to increase owing to lower sheet resistance, while J sc tended to decrease owing to the lower light absorption. In light of this trade-off between sheet resistance and transmittance, we determined that three-layer graphene (3LG) represents the best configuration for obtaining the optimal power conversion efficiency (PCE) in OSC anodes, even at suboptimal sheet resistances. We finally developed efficient, flexible OSCs with a PCE of 4.33%, which is the highest efficiency attained so far by an OSC with CVD-grown graphene electrodes to the best of our knowledge. (paper)

  15. Incidents analysis

    International Nuclear Information System (INIS)

    Francois, P.

    1996-01-01

    We undertook a study programme at the end of 1991. To start with, we performed some exploratory studies aimed at learning some preliminary lessons on this type of analysis: Assessment of the interest of probabilistic incident analysis; possibility of using PSA scenarios; skills and resources required. At the same time, EPN created a working group whose assignment was to define a new approach for analysis of incidents on NPPs. This working group gave thought to both aspects of Operating Feedback that EPN wished to improve: Analysis of significant incidents; analysis of potential consequences. We took part in the work of this group, and for the second aspects, we proposed a method based on an adaptation of the event-tree method in order to establish a link between existing PSA models and actual incidents. Since PSA provides an exhaustive database of accident scenarios applicable to the two most common types of units in France, they are obviously of interest for this sort of analysis. With this method we performed some incident analyses, and at the same time explores some methods employed abroad, particularly ASP (Accident Sequence Precursor, a method used by the NRC). Early in 1994 EDF began a systematic analysis programme. The first, transient phase will set up methods and an organizational structure. 7 figs

  16. Incidents analysis

    Energy Technology Data Exchange (ETDEWEB)

    Francois, P

    1997-12-31

    We undertook a study programme at the end of 1991. To start with, we performed some exploratory studies aimed at learning some preliminary lessons on this type of analysis: Assessment of the interest of probabilistic incident analysis; possibility of using PSA scenarios; skills and resources required. At the same time, EPN created a working group whose assignment was to define a new approach for analysis of incidents on NPPs. This working group gave thought to both aspects of Operating Feedback that EPN wished to improve: Analysis of significant incidents; analysis of potential consequences. We took part in the work of this group, and for the second aspects, we proposed a method based on an adaptation of the event-tree method in order to establish a link between existing PSA models and actual incidents. Since PSA provides an exhaustive database of accident scenarios applicable to the two most common types of units in France, they are obviously of interest for this sort of analysis. With this method we performed some incident analyses, and at the same time explores some methods employed abroad, particularly ASP (Accident Sequence Precursor, a method used by the NRC). Early in 1994 EDF began a systematic analysis programme. The first, transient phase will set up methods and an organizational structure. 7 figs.

  17. Growth studies of CVD-MBE by in-situ diagnostics

    Science.gov (United States)

    Maracas, George N.; Steimle, Timothy C.

    1992-10-01

    This is the final technical report for the three year DARPA-URI program 'Growth Studies of CVD-MBE by in-situ Diagnostics'. The goals of the program were to develop non-invasive, real time epitaxial growth monitoring techniques and combine them to gain an understanding of processes that occur during MBE growth from gas sources. We have adapted these techniques to a commercially designed gas source MBE system (Vacuum Generators Inc.) to facilitate technology transfer out of the laboratory into industrial environments. The in-situ measurement techniques of spectroscopic ellipsometry (SE) and laser induced fluorescence (LIF) have been successfully implemented to monitor the optical and chemical properties of the growing epitaxial film and the gas phase reactants. The ellipsometer was jointly developed with the J. Woolam Co. and has become a commercial product. The temperature dependence of group 3 and 5 desorption from GaAs and InP has been measured as well as the incident effusion cell fluxes. The temporal evolution of the growth has also been measured both by SE and LIF to show the smoothing of heterojunction surfaces during growth interruption. Complicated microcavity optical device structures have been monitored by ellipsometry in real time to improve device quality. This data has been coupled with the structural information obtained from reflection high energy electron diffraction (RHEED) to understand the growth processes in binary and ternary bulk 3-5 semiconductors and heterojunctions.

  18. Universal Design: Supporting Students with Color Vision Deficiency (CVD) in Medical Education

    Science.gov (United States)

    Meeks, Lisa M.; Jain, Neera R.; Herzer, Kurt R.

    2016-01-01

    Color Vision Deficiency (CVD) is a commonly occurring condition in the general population. For medical students, it has the potential to create unique challenges in the classroom and clinical environments. Few studies have provided medical educators with comprehensive recommendations to assist students with CVD. This article presents a focused…

  19. Origin, state of the art and some prospects of the diamond CVD

    CERN Document Server

    Spitsyn, B V; Alexenko, A E

    2000-01-01

    A short review on the diamond CVD origin, together with its state of the art and some prospects was given. New hybrid methods of the diamond CVD permit to gain 1.2 to 6 times of growth rate in comparison with ordinary diamond CVD's. Recent results on n-type diamond film synthesis through phosphorus doping in the course of the CVD process are briefly discussed. In comparison with high-pressure diamond synthesis, the CVD processes open new facets of the diamond as ultimate crystal for science and technology evolution. It was stressed that, mainly on the basis of new CVDs of diamond, the properties of natural diamond are not only reproduced, but can be surpassed. As examples, mechanical (fracture resistance), physical (thermal conductivity), and chemical (oxidation stability) properties are mentioned. Some present issues in the field are considered.

  20. 25th anniversary article: CVD polymers: a new paradigm for surface modification and device fabrication.

    Science.gov (United States)

    Coclite, Anna Maria; Howden, Rachel M; Borrelli, David C; Petruczok, Christy D; Yang, Rong; Yagüe, Jose Luis; Ugur, Asli; Chen, Nan; Lee, Sunghwan; Jo, Won Jun; Liu, Andong; Wang, Xiaoxue; Gleason, Karen K

    2013-10-11

    Well-adhered, conformal, thin (polymers can be achieved on virtually any substrate: organic, inorganic, rigid, flexible, planar, three-dimensional, dense, or porous. In CVD polymerization, the monomer(s) are delivered to the surface through the vapor phase and then undergo simultaneous polymerization and thin film formation. By eliminating the need to dissolve macromolecules, CVD enables insoluble polymers to be coated and prevents solvent damage to the substrate. CVD film growth proceeds from the substrate up, allowing for interfacial engineering, real-time monitoring, and thickness control. Initiated-CVD shows successful results in terms of rationally designed micro- and nanoengineered materials to control molecular interactions at material surfaces. The success of oxidative-CVD is mainly demonstrated for the deposition of organic conducting and semiconducting polymers. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Unprocessed Meat Consumption and Incident Cardiovascular Diseases in Korean Adults: The Korean Genome and Epidemiology Study (KoGES

    Directory of Open Access Journals (Sweden)

    Kyong Park

    2017-05-01

    Full Text Available Meat consumption has been shown to be associated with cardiovascular disease (CVD risk in Western societies; however, epidemiological data are limited on the Korean population. Therefore, we examined the associations between unprocessed meat consumption and CVD incidence in Korea. Data were derived from the Ansung-Ansan cohort (2001–2012, including 9370 adults (40–69 years without CVD or cancer at baseline. Total unprocessed meat consumption was estimated as the sum of unprocessed red meat (beef, pork, and organ meat and poultry consumption. In the fully adjusted Cox regression model, the relative risks of CVD across increasing quintiles of total unprocessed meat intake were 1.0 (reference, 0.72 (95% confidence interval (CI: 0.55, 0.95, 0.57 (95% CI: 0.42, 0.78, 0.69 (95% CI: 0.51, 0.95, and 0.69 (95% CI: 0.48, 0.97, but no significant linear trend was detected (p for trend = 0.14. Frequent poultry consumption was significantly associated with a decreased CVD risk; this association showed a dose-response relationship (p for trend = 0.04. This study showed that a moderate intake of total unprocessed meat was inversely associated with CVD risk. A significant inverse association between poultry consumption and incident CVD was observed in Korean adults, requiring further confirmation in other populations.

  2. Unprocessed Meat Consumption and Incident Cardiovascular Diseases in Korean Adults: The Korean Genome and Epidemiology Study (KoGES)

    Science.gov (United States)

    Park, Kyong; Son, Jakyung; Jang, Jiyoung; Kang, Ryungwoo; Chung, Hye-Kyung; Lee, Kyong Won; Lee, Seung-Min; Lim, Hyunjung; Shin, Min-Jeong

    2017-01-01

    Meat consumption has been shown to be associated with cardiovascular disease (CVD) risk in Western societies; however, epidemiological data are limited on the Korean population. Therefore, we examined the associations between unprocessed meat consumption and CVD incidence in Korea. Data were derived from the Ansung-Ansan cohort (2001–2012), including 9370 adults (40–69 years) without CVD or cancer at baseline. Total unprocessed meat consumption was estimated as the sum of unprocessed red meat (beef, pork, and organ meat) and poultry consumption. In the fully adjusted Cox regression model, the relative risks of CVD across increasing quintiles of total unprocessed meat intake were 1.0 (reference), 0.72 (95% confidence interval (CI): 0.55, 0.95), 0.57 (95% CI: 0.42, 0.78), 0.69 (95% CI: 0.51, 0.95), and 0.69 (95% CI: 0.48, 0.97), but no significant linear trend was detected (p for trend = 0.14). Frequent poultry consumption was significantly associated with a decreased CVD risk; this association showed a dose-response relationship (p for trend = 0.04). This study showed that a moderate intake of total unprocessed meat was inversely associated with CVD risk. A significant inverse association between poultry consumption and incident CVD was observed in Korean adults, requiring further confirmation in other populations. PMID:28505126

  3. Renal function, cardiovascular disease risk factors' prevalence and 5-year disease incidence; the role of diet, exercise, lipids and inflammation markers: the ATTICA study.

    Science.gov (United States)

    Chrysohoou, C; Panagiotakos, D B; Pitsavos, C; Skoumas, J; Toutouza, M; Papaioannou, I; Stefanadis, C

    2010-06-01

    We aimed to evaluate the association between renal function and various cardiovascular disease (CVD) risk factors, as well as 5-year incidence of CVD, in a sample of CVD free adults. (i) Cross-sectional information from n = 1975. Greek men and women (>18 years) without CVD and hypertension at baseline examination and (ii) 5-year (2001-06) survival data from n = 2101 individuals without CVD at baseline, all participants in the ATTICA study, were analysed in this work. Kidney function was quantified by the baseline estimated creatinine clearance rate (C(cr)), using the Cockcroft-Gault formula and the National Kidney Foundation recommendations. Outcome of interest was the development of CVD that was defined according to WHO-ICD-10 criteria. At baseline, the prevalence of moderate-to-severe renal dysfunction (i.e. C(cr) smoking, hypercholesterolemia and homocysteine levels and greater adherence to the Mediterranean diet were inversely associated with C(cr) rate (P smoking habits (0.89, 0.60-1.32) and physical activity status (0.86, 0.56-1.21). Renal function seems to be associated with the levels of lifestyle and bio-clinical CVD risk factors and contribute to the long-term incidence of cardiac events. Public health care practitioners should take into account renal function in better preventing the burden of CVD at individual, and population level, as well.

  4. Facility for continuous CVD coating of ceramic fibers

    International Nuclear Information System (INIS)

    Moore, A.W.

    1992-01-01

    The development of new and improved ceramic fibers has spurred the development and application of ceramic composites with improved strength, strength/weight ratio, toughness, and durability at increasingly high temperatures. For many systems, the ceramic fibers can be used without modification because their properties are adequate for the chosen application. However, in order to take maximum advantage of the fiber properties, it is often necessary to coat the ceramic fibers with materials of different composition and properties. Examples include (1) boron nitride coatings on a ceramic fiber, such as Nicalon silicon carbide, to prevent reaction with the ceramic matrix during fabrication and to enhance fiber pullout and increase toughness when the ceramic composite is subjected to stress; (2) boron nitride coatings on ceramic yarns, such as Nicalon for use as thermal insulation panels in an aerodynamic environment, to reduce abrasion of the Nicalon and to inhibit the oxidation of free carbon contained within the Nicalon; and (3) ceramic coatings on carbon yarns and carbon-carbon composites to permit use of these high-strength, high-temperature materials in oxidizing environments at very high temperatures. This paper describes a pilot-plant-sized CVD facility for continuous coating of ceramic fibers and some of the results obtained so far with this equipment

  5. Selective tungsten deposition in a batch cold wall CVD system

    International Nuclear Information System (INIS)

    Chow, R.; Kang, S.; Harshbarger, W.R.; Susoeff, M.

    1987-01-01

    Selective deposition of tungsten offers many advantages for VLSI technology. The process can be used as a planarization technique for multilevel interconnect technology, it can be used to fill contacts and to provide a barrier layer between Al and Si materials, and the selective W process might be used as a self-aligned technology to provide low resistance layers on source/drain and gate conductors. Recent publications have indicate that cold wall CVD systems provide advantages for development of selective W process. Genus has investigated selective W deposition processing, and we have developed a selective W deposition process for the Genus 8402 multifilm deposition system. This paper describes the Genus 8402 system and the selective W process developed in this reactor. To further develop selective W technology, Genus has signed an agreement with General Electric establishing a joint development program. As a part of this program, the authors characterized the selective W process for encroachment, Si consumption and degrees of selectivity on various dielectrics. The status of this development activity and process characterization is reviewed in this paper

  6. Carbon Nanotubes Growth by CVD on Graphite Fibers

    Science.gov (United States)

    Zhu, Shen; Su, Ching-Hua; Cochrane, J. C.; Lehoczky, S. L.; Muntele, I.; Ila, D.; Curreri, Peter A. (Technical Monitor)

    2002-01-01

    Due to the superior electrical and mechanical properties of carbon nanotubes (CNT), synthesizing CNT on various substances for electronics devices and reinforced composites have been engaged in many efforts for applications. This presentation will illustrate CNT synthesized on graphite fibers by thermal CVD. On the fiber surface, iron nanoparticles as catalysts for CNT growth are coated. The growth temperature ranges from 600 to 1000 C and the pressure ranges from 100 Torr to one atmosphere. Methane and hydrogen gases with methane content of 10% to 100% are used for the CNT synthesis. At high growth temperatures (greater than or equal to 900 C), the rapid inter-diffusion of the transition metal iron on the graphite surface results in the rough fiber surface without any CNT grown on it. When the growth temperature is relative low (650-800 C), CNT with catalytic particles on the nanotube top ends are fabricated on the graphite surface. (Methane and hydrogen gases with methane content of 10% to 100% are used for the CNT synthesis.) (By measuring the samples) Using micro Raman spectroscopy in the breath mode region, single-walled or multi-walled CNT (MWCNT), depending on growth concentrations, are found. Morphology, length and diameter of these MWCNT are determined by scanning electron microscopy and Raman spectroscopy. The detailed results of syntheses and characterizations will be discussed in the presentation.

  7. Cyclic voltammetry response of an undoped CVD diamond electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Fabisiak, K., E-mail: kfab@ukw.edu.pl [Institute of Physics, Kazimierz Wielki University, Powstancow Wielkopolskich 2, 85-090 Bydgoszcz (Poland); Torz-Piotrowska, R. [Faculty of Chemical Technology and Engineering, UTLS Seminaryjna 3, 85-326 Bydgoszcz (Poland); Staryga, E. [Institute of Physics, Technical University of Lodz, Wolczanska 219, 90-924 Lodz (Poland); Szybowicz, M. [Faculty of Technical Physics, Poznan University of Technology, Nieszawska 13A, 60-965 Poznan (Poland); Paprocki, K.; Popielarski, P.; Bylicki, F. [Institute of Physics, Kazimierz Wielki University, Powstancow Wielkopolskich 2, 85-090 Bydgoszcz (Poland); Wrzyszczynski, A. [Institute of Physics, Technical University of Lodz, Wolczanska 219, 90-924 Lodz (Poland)

    2012-09-01

    Highlights: Black-Right-Pointing-Pointer Correlation was found between diamond quality and its electrochemical performance. Black-Right-Pointing-Pointer The electrode sensitivity depends on the content of sp{sup 2} carbon phase in diamond layer. Black-Right-Pointing-Pointer The sp{sup 2} carbon phase content has little influence on the CV peak separation ({Delta}E{sub p}). - Abstract: The polycrystalline undoped diamond layers were deposited on tungsten wire substrates by using hot filament chemical vapor deposition (HFCVD) technique. As a working gas the mixture of methanol in excess of hydrogen was used. The morphologies and quality of as-deposited films were monitored by means of scanning electron microscopy (SEM), X-ray diffraction (XRD) and Raman spectroscopy respectively. The electrochemical activity of the obtained diamond layers was monitored by using cyclic voltammetry measurements. Analysis of the ferrocyanide-ferricyanide couple at undoped diamond electrode suggests that electrochemical reaction at diamond electrode has a quasireversibile character. The ratio of the anodic and cathodic peak currents was always close to unity. In this work we showed that the amorphous carbon admixture in the CVD diamond layer has a crucial influence on its electrochemical performance.

  8. A Fast CVD Diamond Beam Loss Monitor for LHC

    CERN Document Server

    Griesmayer, E; Dobos, D; Effinger, E; Pernegger, H

    2011-01-01

    Chemical Vapour Deposition (CVD) diamond detectors were installed in the collimation area of the CERN LHC to study their feasibility as Fast Beam Loss Monitors in a high-radiation environment. The detectors were configured with a fast, radiation-hard pre-amplifier with a bandwidth of 2 GHz. The readout was via an oscilloscope with a bandwidth of 1 GHz and a sampling rate of 5 GSPS. Despite the 250 m cable run from the detectors to the oscilloscope, single MIPs were resolved with a 2 ns rise time, a pulse width of 10 ns and a time resolution of less than 1 ns. Two modes of operation were applied. For the analysis of unexpected beam aborts, the loss profile was recorded in a 1 ms buffer and, for nominal operation, the histogram of the time structure of the losses was recorded in synchronism with the LHC period of 89.2 μs. Measurements during the LHC start-up (February to December 2010) are presented. The Diamond Monitors gave an unprecedented insight into the time structure of the beam losses resolving the 400...

  9. Investigation of laser ablation of CVD diamond film

    Science.gov (United States)

    Chao, Choung-Lii; Chou, W. C.; Ma, Kung-Jen; Chen, Ta-Tung; Liu, Y. M.; Kuo, Y. S.; Chen, Ying-Tung

    2005-04-01

    Diamond, having many advanced physical and mechanical properties, is one of the most important materials used in the mechanical, telecommunication and optoelectronic industry. However, high hardness value and extreme brittleness have made diamond extremely difficult to be machined by conventional mechanical grinding and polishing. In the present study, the microwave CVD method was employed to produce epitaxial diamond films on silicon single crystal. Laser ablation experiments were then conducted on the obtained diamond films. The underlying material removal mechanisms, microstructure of the machined surface and related machining conditions were also investigated. It was found that during the laser ablation, peaks of the diamond grains were removed mainly by the photo-thermal effects introduced by excimer laser. The diamond structures of the protruded diamond grains were transformed by the laser photonic energy into graphite, amorphous diamond and amorphous carbon which were removed by the subsequent laser shots. As the protruding peaks gradually removed from the surface the removal rate decreased. Surface roughness (Ra) was improved from above 1μm to around 0.1μm in few minutes time in this study. However, a scanning technique would be required if a large area was to be polished by laser and, as a consequence, it could be very time consuming.

  10. Experimental studies of N~+ implantation into CVD diamond thin films

    Institute of Scientific and Technical Information of China (English)

    辛火平; 林成鲁; 王建新; 邹世昌; 石晓红; 林梓鑫; 周祖尧; 刘祖刚

    1997-01-01

    The effects of N+ implantation under various conditions on CVD diamond films were analyzed with Raman spectroscopy, four-point probe method, X-ray diffraction (XRD), Rutherford backseattering spectroscopy (RBS), ultraviolet photoluminescence spectroscopy (UV-PL), Fourier transformation infrared absorption spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS). The results show that the N+ implantation doping without any graphitization has been successfully realized when 100 keV N+ ions at a dosage of 2 × 1016 cm-2 were implanted into diamond films at 550℃ . UV-PL spectra indicate that the implanted N+ ions formed an electrically inactive deep-level impurity in diamond films. So the sheet resistance of the sample after N+ implantation changed little. Carbon nitride containing C≡N covalent bond has been successfully synthesized by 100 keV, 1.2×1018 N/cm2 N+ implantation into diamond films. Most of the implanted N+ ions formed C≡N covalent bonds with C atoms. The others were free state nitroge

  11. Case studies of hydrogen sulphide occupational exposure incidents in the UK.

    Science.gov (United States)

    Jones, Kate

    2014-12-15

    The UK Health and Safety Executive has investigated several incidents of workplace accidents involving hydrogen sulphide exposure in recent years. Biological monitoring has been used in some incidents to determine the cause of unconsciousness resulting from these incidents and as a supporting evidence in regulatory enforcement. This paper reports on three case incidents and discusses the use of biological monitoring in such cases. Biological monitoring has a role in identifying hydrogen sulphide exposure in incidents, whether these are occupational or in the wider environment. Sample type, time of collection and sample storage are important factors in the applicability of this technique. For non-fatal incidents, multiple urine samples are recommended at two or more time points between the incident and 15 h post-exposure. For routine occupational monitoring, post-shift samples should be adequate. Due to endogenous levels of urinary thiosulphate, it is likely that exposures in excess of 12 ppm for 30 min (or 360 ppm/min equivalent) would be detectable using biological monitoring. This is within the Acute Exposure Guideline Level 2 (the level of the chemical in air at or above which there may be irreversible or other serious long-lasting effects or impaired ability to escape) for hydrogen sulphide. Crown Copyright © 2014. Published by Elsevier Ireland Ltd. All rights reserved.

  12. CVD and obesity in transitional Syria: a perspective from the Middle East.

    Science.gov (United States)

    Barakat, Hani; Barakat, Hanniya; Baaj, Mohamad K

    2012-01-01

    Syria is caught in the middle of a disruptive nutritional transition. Its healthcare system is distracted by challenges and successes in other areas while neglecting to address the onslaught of Syria's cardiovascular disease (CVD) epidemic. Despite the official viewpoint touting improvement in health indicators, current trends jeopardize population health, and several surveys in the Syrian population signal the epidemic spreading far and wide. The goal is to counteract the indifference towards obesity as a threat to Syrian's health, as the country is slowly becoming a leader in CVD mortality globally. PubMed, World Health Organization, and official government websites were searched for primary surveys in Syria related to CVD morbidity, mortality, and risk factors. Inclusion criteria ensured that results maximized relevance while producing comparable studies. Statistical analysis was applied to detect the most common risk factor and significant differences in risk factor prevalence and CVD rates. Obesity remained the prevailing CVD risk factor except in older Syrian men, where smoking and hypertension were more common. CVD mortality was more common in males due to coronary disease, while stroke dominated female mortality. The young workforce is especially impacted, with 50% of CVD mortality occurring before age 65 years and an 81% prevalence of obesity in women over 45 years. Syria can overcome its slow response to the CVD epidemic and curb further deterioration by reducing obesity and, thus, inheritance and clustering of risk factors. This can be achieved via multilayered awareness and intensive parental and familial involvement. Extinguishing the CVD epidemic is readily achievable as demonstrated in other countries.

  13. Development of a CVD silica coating for UK advanced gas-cooled nuclear reactor fuel pins

    International Nuclear Information System (INIS)

    Bennett, M.J.; Houlton, M.R.; Moore, D.A.; Foster, A.I.; Swidzinski, M.A.M.

    1983-04-01

    Vapour deposited silica coatings could extend the life of the 20% Cr/25% Ni niobium stabilised (20/25/Nb) stainless steel fuel cladding of the UK advanced gas cooled reactors. A CVD coating process developed originally to be undertaken at atmospheric pressure has now been adapted for operation at reduced pressure. Trials on the LP CVD process have been pursued to the production scale using commercial equipment. The effectiveness of the LP CVD silica coatings in providing protection to 20/25/Nb steel surfaces against oxidation and carbonaceous deposition has been evaluated. (author)

  14. Radiation monitoring with CVD diamonds and PIN diodes at BaBar

    Energy Technology Data Exchange (ETDEWEB)

    Bruinsma, M. [University of California Irvine, Irvine, CA 92697 (United States); Burchat, P. [Stanford University, Stanford, CA 94305-4060 (United States); Curry, S. [University of California Irvine, Irvine, CA 92697 (United States)], E-mail: scurry@slac.stanford.edu; Edwards, A.J. [Stanford University, Stanford, CA 94305-4060 (United States); Kagan, H.; Kass, R. [Ohio State University, Columbus, OH 43210 (United States); Kirkby, D. [University of California Irvine, Irvine, CA 92697 (United States); Majewski, S.; Petersen, B.A. [Stanford University, Stanford, CA 94305-4060 (United States)

    2007-12-11

    The BaBar experiment at the Stanford Linear Accelerator Center has been using two polycrystalline chemical vapor deposition (pCVD) diamonds and 12 silicon PIN diodes for radiation monitoring and protection of the Silicon Vertex Tracker (SVT). We have used the pCVD diamonds for more than 3 years, and the PIN diodes for 7 years. We will describe the SVT and SVT radiation monitoring system as well as the operational difficulties and radiation damage effects on the PIN diodes and pCVD diamonds in a high-energy physics environment.

  15. Multilayered and composite PVD-CVD coatings in cemented carbides manufacture

    International Nuclear Information System (INIS)

    Glushkov, V.N.; Anikeev, A.I.; Anikin, V.N.; Vereshchaka, A.S.

    2001-01-01

    Carbide cutting tools with wear-resistant coatings deposited by CVD process are widely employed in mechanical engineering to ensure a substantially longer service life of tool systems. However, the relatively high temperature and long time of the process make the substrate decarburise and, as a result, the bend strength and performance characteristics of a tool decrease. The present study suggests the problem of deteriorated strength of CVD-coated carbide tools be solved by the development of a technology that combines arc-PVD and CVD processes to deposit multilayered coatings of titanium and aluminium compounds. (author)

  16. Treatment with liraglutide may improve markers of CVD reflected by reduced levels of apoB

    DEFF Research Database (Denmark)

    Engelbrechtsen, Line; Lundgren, J; Wewer Albrechtsen, Nicolai Jacob

    2017-01-01

    Background: Dislipidaemia and increased levels of apolipoprotein B (apoB) in individuals with obesity are risk factors for development of cardiovascular disease (CVD). The aim of this study was to investigate the effect of weight loss and weight maintenance with and without liraglutide treatment ......B, despite similar body weight maintenance. Treatment with liraglutide may therefore reduce apoB levels and thus reflect lower CVD risk. Including apoB measurements in clinical practice when monitoring patients with dislipidemia or CVD might prove to be useful....

  17. Incidence of Stroke and Transient Ischemic Attack in Croatia: A Population Based Study.

    Science.gov (United States)

    Kadojić, Dragutin; Demarin, Vida; Dikanović, Marinko; Lusić, Ivo; Tuskan-Mohar, Lidija; Trkanjec, Zlatko; Mihaljević, Ivan; Kadojić, Mira; Bitunjac, Milan; Vranjes, Zeljko

    2015-09-01

    The aim of this population based neuroepidemiological study was to establish the real incidence rates of acute cerebrovascular disease (CVD): stroke and transient ischemic attack (TIA) in the Republic of Croatia. Multicentric study included 89 501 persons of all ages in four regional centres in Croatia: Zagreb, Osijek + Slavonski Brod, Rijeka and Split. The following incidence rates of stroke, expressed at population of 100 000, have been established: Zagreb 290.52, Osijek + Slavonski Brod 302.14, Rijeka 219.65, Split 195.82. Incidence rate of stroke for the Republic of Croatia is 251.39. The following incidence rates of TIA, expressed at population of 100,000, have been established: Zagreb 87.15, Osijek + Slavonski Brod 156.53, Rijeka 90.11, Split 59.10. Incidence rate of TIA for the Republic of Croatia is 100.55. In the continental part of Croatia (Zagreb, Osijek + Slavonski Brod) incidence rate of stroke is higher by 45%, while incidence rate of TIA is higher by 82% than in the coastal part of Croatia, probably due to different lifestyle and environmental factors. The study has shown relatively high incidence rates of acute CVD (stroke and TIA) in the Republic of Croatia, which proves that CVD are a great public health problem.

  18. A case-crossover study of sleep, fatigue, and other transient exposures at workplace and the risk of non-fatal occupational injuries among the employees of an Italian academic hospital

    Directory of Open Access Journals (Sweden)

    Francesca Valent

    2016-12-01

    Full Text Available Objectives: Transient exposure with acute effect has been shown to affect the risk of occupational injuries in various industrial settings and at the healthcare workplace. The objective of this study has been to identify transient exposures related to occupational injury risk in an Italian teaching hospital. Material and Methods: A case-crossover study was conducted among the employees of the University Hospital of Udine who reported an occupational injury, commuting accident, or incident involving biological risk in a 15-month period in the years 2013 and 2014. The matched-pair interval approach was used to assess the role of acute sleep deprivation whereas the usual frequency approach was used for other 13 transient exposures. Results: Sleep hours were not associated with the risk of injuries whereas a significant risk increase was associated with fatigue, rush, distraction, emergency situations, teaching to or being taught by someone, non-compliant patients, bloody operative/work field, excess noise, complex procedures, and anger. Conclusions: We identified transient exposures that increased the risk of occupational injuries in an Italian teaching hospital, providing indications for interventions to increase workers’ safety at the healthcare workplace. Int J Occup Med Environ Health 2016;29(6:1001–1009

  19. CVD transfer-free graphene for sensing applications

    Directory of Open Access Journals (Sweden)

    Chiara Schiattarella

    2017-05-01

    Full Text Available The sp2 carbon-based allotropes have been extensively exploited for the realization of gas sensors in the recent years because of their high conductivity and large specific surface area. A study on graphene that was synthetized by means of a novel transfer-free fabrication approach and is employed as sensing material is herein presented. Multilayer graphene was deposited by chemical vapour deposition (CVD mediated by CMOS-compatible Mo. The utilized technique takes advantage of the absence of damage or contamination of the synthesized graphene, because there is no need for the transfer onto a substrate. Moreover, a proper pre-patterning of the Mo catalyst allows one to obtain graphene films with different shapes and dimensions. The sensing properties of the material have been investigated by exposing the devices to NO2, NH3 and CO, which have been selected because they are well-known hazardous substances. The concentration ranges have been chosen according to the conventional monitoring of these gases. The measurements have been carried out in humid N2 environment, setting the flow rate at 500 sccm, the temperature at 25 °C and the relative humidity (RH at 50%. An increase of the conductance response has been recorded upon exposure towards NO2, whereas a decrease of the signal has been detected towards NH3. The material appears totally insensitive towards CO. Finally, the sensing selectivity has been proven by evaluating and comparing the degree of adsorption and the interaction energies for NO2 and NH3 on graphene. The direct-growth approach for the synthesis of graphene opens a promising path towards diverse applicative scenarios, including the straightforward integration in electronic devices.

  20. A study of diaschisis in CVD using MR-CT

    International Nuclear Information System (INIS)

    Okada, Akihiko; Fujimoto, Toshiro; Uetsuhara, Koichi; Asakura, Tetsuhiko; Osame, Mitsuhiro; Igata, Akihiro.

    1987-01-01

    The presence of diaschisis in the non-infarct cerebral areas in a cerebro-vascular disorder (CVD) has been reported using PET and cerebral-blood flowmetry. We are not aware, however, of any report studying this diaschisis by means of the method of magnetic resonance imaging (MRI). In this connection, we studied brain MRI in 38 patients with cerebral infarctions. The T 1 relaxation time was estimated in the white and grey matters of the frontal, temporal, and occipital lobes and the thalamus, including the cerebral white matter of both the infarct and non-infarct sides. In the major-stroke group, significant increases (all P 1 relaxation time were observed in the thalamus of the infarct side, as well as in the thalamus and the white matter of the occipital lobe on the non-infarct side. In the minor-stroke group, significant increases (all P 1 relaxation time were also observed in all areas except the frontal-lobe white matter of the infarct and non-infarct sides. We have thus proved the presence of diaschisis through the method of MRI by evaluating the T 1 relaxation time. An analysis of the time profile of the T 1 relaxation time in each area demonstrated that the T 1 relaxation time tended to show its greatest value between 2 weeks and 2 months and thereafter gradually decreased, reaching the normal range 2 months later in the white matter of both the infarct and non-infarct sides. The T 1 relaxation time in the thalamus of the infarct side, however, decreased between 2 weeks and 2 months and then increased again. Therefore, we were able to show different time profiles of the diaschisis in various areas of the brain through the analysis of the T 1 relaxation time in MRI. (author)

  1. CVD transfer-free graphene for sensing applications.

    Science.gov (United States)

    Schiattarella, Chiara; Vollebregt, Sten; Polichetti, Tiziana; Alfano, Brigida; Massera, Ettore; Miglietta, Maria Lucia; Di Francia, Girolamo; Sarro, Pasqualina Maria

    2017-01-01

    The sp 2 carbon-based allotropes have been extensively exploited for the realization of gas sensors in the recent years because of their high conductivity and large specific surface area. A study on graphene that was synthetized by means of a novel transfer-free fabrication approach and is employed as sensing material is herein presented. Multilayer graphene was deposited by chemical vapour deposition (CVD) mediated by CMOS-compatible Mo. The utilized technique takes advantage of the absence of damage or contamination of the synthesized graphene, because there is no need for the transfer onto a substrate. Moreover, a proper pre-patterning of the Mo catalyst allows one to obtain graphene films with different shapes and dimensions. The sensing properties of the material have been investigated by exposing the devices to NO 2 , NH 3 and CO, which have been selected because they are well-known hazardous substances. The concentration ranges have been chosen according to the conventional monitoring of these gases. The measurements have been carried out in humid N 2 environment, setting the flow rate at 500 sccm, the temperature at 25 °C and the relative humidity (RH) at 50%. An increase of the conductance response has been recorded upon exposure towards NO 2 , whereas a decrease of the signal has been detected towards NH 3 . The material appears totally insensitive towards CO. Finally, the sensing selectivity has been proven by evaluating and comparing the degree of adsorption and the interaction energies for NO 2 and NH 3 on graphene. The direct-growth approach for the synthesis of graphene opens a promising path towards diverse applicative scenarios, including the straightforward integration in electronic devices.

  2. Chemical vapor deposition (CVD) of uranium for alpha spectrometry

    International Nuclear Information System (INIS)

    Ramirez V, M. L.; Rios M, C.; Ramirez O, J.; Davila R, J. I.; Mireles G, F.

    2015-09-01

    The uranium determination through radiometric techniques as alpha spectrometry requires for its proper analysis, preparation methods of the source to analyze and procedures for the deposit of this on a surface or substrate. Given the characteristics of alpha particles (small penetration distance and great loss of energy during their journey or its interaction with the matter), is important to ensure that the prepared sources are thin, to avoid problems of self-absorption. The routine methods used for this are the cathodic electro deposition and the direct evaporation, among others. In this paper the use of technique of chemical vapor deposition (CVD) for the preparation of uranium sources is investigated; because by this, is possible to obtain thin films (much thinner than those resulting from electro deposition or evaporation) on a substrate and comprises reacting a precursor with a gas, which in turn serves as a carrier of the reaction products to achieve deposition. Preliminary results of the chemical vapor deposition of uranium are presented, synthesizing and using as precursor molecule the uranyl acetylacetonate, using oxygen as carrier gas for the deposition reaction on a glass substrate. The uranium films obtained were found suitable for alpha spectrometry. The variables taken into account were the precursor sublimation temperatures and deposition temperature, the reaction time and the type and flow of carrier gas. Of the investigated conditions, two depositions with encouraging results that can serve as reference for further work to improve the technique presented here were selected. Alpha spectra obtained for these depositions and the characterization of the representative samples by scanning electron microscopy and X-ray diffraction are also presented. (Author)

  3. Lithium storage properties of multiwall carbon nanotubes prepared by CVD

    International Nuclear Information System (INIS)

    Ahn, J.-O.; Andong National University,; Wang, G.X.; Liu, H.K.; Dou, S.X.

    2003-01-01

    Full text: Multiwall carbon nanotubes (MWCNTs) were synthesised by chemical vapour deposition (CVD) method using acetylene gas. The XRD pattern of as prepared carbon nanotubes showed that the d 002 value is 3.44 Angstroms. The morphology and microstructure of carbon nanotubes were characterized by HRTEM. Most of carbon nanotubes are entangled together to form bundles or ropes. The diameter of the carbon nanotubes is in the range of 10 ∼ 20 nm. There is a small amount of amorphous carbon particles presented in the sample. However, the yield of carbon nanotubes is more than 95%. Electrochemical properties of carbon nanotubes were characterised via a variety of electrochemical testing techniques. The result of CV test showed that the Li insertion potential is quite low, which is very close to O V versus Li + /Li reference electrode, whereas the potential for Li de-intercalation is in the range of 0.2-0.4 V. There exists a slight voltage hysteresis between Li intercalation and Li de-intercalation, which is similar to the other carbonaceous materials. The intensity of redox peaks of carbon nanotubes decrease with scanning cycle, indicating that the reversible Li insertion capacity gradually decreases. The carbon nanotubes electrode demonstrated a reversible lithium storage capacity of 340 mAh/g with good cyclability at moderate current density. Further improvement of Li storage capacity is possible by opening the end of carbon nanotubes to allow lithium insertion into inner graphene sheet of carbon nanotubes. The kinetic properties of lithium insertion in carbon nanotube electrodes were characterised by a.c. impedance measurements. It was found that the lithium diffusion coefficient d Li decreases with an increase of Li ion concentration in carbon nanotube host

  4. Cutting characteristics of dental diamond burs made with CVD technology Características de corte de pontas odontológicas diamantadas obtidas pela tecnologia CVD

    Directory of Open Access Journals (Sweden)

    Luciana Monti Lima

    2006-04-01

    Full Text Available The aim of this study was to determine the cutting ability of chemical vapor deposition (CVD diamond burs coupled to an ultrasonic dental unit handpiece for minimally invasive cavity preparation. One standard cavity was prepared on the mesial and distal surfaces of 40 extracted human third molars either with cylindrical or with spherical CVD burs. The cutting ability was compared regarding type of substrate (enamel and dentin and direction of handpiece motion. The morphological characteristics, width and depth of the cavities were analyzed and measured using scanning electron micrographs. Statistical analysis using the Kruskal-Wallis test (p O objetivo deste estudo foi determinar a habilidade de corte das pontas de diamante obtidas pelo processo de deposição química a vapor (CVD associadas ao aparelho de ultra-som no preparo cavitário minimamente invasivo. Uma cavidade padronizada foi preparada nas faces mesial e distal de 40 terceiros molares, utilizando-se pontas de diamante CVD cilíndrica e esférica. A habilidade de corte foi comparada quanto ao tipo de substrato (esmalte e dentina e quanto à direção do movimento realizado com a ponta. As características morfológicas, a largura e profundidade das cavidades foram analisadas e medidas em microscopia eletrônica de varredura. A análise estatística pelo teste de Kruskal-Wallis (p < 0,05 revelou que a largura e profundidade das cavidades foram significativamente maiores em dentina. Cavidades mais largas foram obtidas quando se utilizou a ponta de diamante CVD cilíndrica, e mais profundas quando a ponta esférica foi empregada. A direção do movimento da ponta não influenciou o tamanho das cavidades, sendo os cortes produzidos pelas pontas de diamante CVD precisos e conservadores.

  5. Selective CVD tungsten on silicon implanted SiO/sub 2/

    International Nuclear Information System (INIS)

    Hennessy, W.A.; Ghezzo, M.; Wilson, R.H.; Bakhru, H.

    1988-01-01

    The application range of selective CVD tungsten is extended by its coupling to the ion implantation of insulating materials. This article documents the results of selective CVD tungsten using silicon implanted into SiO/sub 2/ to nucleate the tungsten growth. The role of implant does, energy, and surface preparation in achieving nucleation are described. SEM micrographs are presented to demonstrate the selectivity of this process. Measurements of the tungsten film thickness and sheet resistance are provided for each of the experimental variants corresponding to successful deposition. RBS and XPS analysis are discussed in terms of characterizing the tungsten/oxide interface and to evaluate the role of the silicon implant in the CVD tungsten mechanism. Utilizing this method a desired metallization pattern can be readily defined with lithography and ion implantation, and accurately replicated with a layer of CVD tungsten. This approach avoids problems usually associated with blanket deposition and pattern transfer, which are particularly troublesome for submicron VLSI technology

  6. High-efficiency supercapacitor electrodes of CVD-grown graphenes hybridized with multiwalled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Kalam, Amir Abul; Bae, Joon Ho [Dept. of Nano-physics, Gachon University, Seongnam (Korea, Republic of); Park, Soo Bin; Seo, Yong Ho [Nanotechnology and Advanced Material Engineering, HMC, and GRI, Sejong University, Seoul (Korea, Republic of)

    2015-08-15

    We demonstrate, for the first time, high-efficiency supercapacitors by utilizing chemical vapor deposition (CVD)-grown graphenes hybridized with multiwalled carbon nanotubes (CNTs). A single-layer graphene was grown by simple CVD growth method, and transferred to polyethylene terephthalate substrates. The bare graphenes were further hybridized with multiwalled CNTs by drop-coating CNTs on graphenes. The supercapacitors using bare graphenes and graphenes with CNTs revealed that graphenes with CNTs resulted in enhanced supercapacitor performances of 2.2- (the mass-specific capacitance) and 4.4-fold (the area-specific capacitance) of those of bare graphenes. Our strategy to improve electrochemical performance of CVD-grown graphenes is advantageous for large-scale graphene electrodes due to high electrical conductivity of CVD-grown graphenes and cost-effectiveness of using multiwalled CNTs as compared to conventional employment of single-walled CNTs.

  7. High-efficiency supercapacitor electrodes of CVD-grown graphenes hybridized with multiwalled carbon nanotubes

    International Nuclear Information System (INIS)

    Kalam, Amir Abul; Bae, Joon Ho; Park, Soo Bin; Seo, Yong Ho

    2015-01-01

    We demonstrate, for the first time, high-efficiency supercapacitors by utilizing chemical vapor deposition (CVD)-grown graphenes hybridized with multiwalled carbon nanotubes (CNTs). A single-layer graphene was grown by simple CVD growth method, and transferred to polyethylene terephthalate substrates. The bare graphenes were further hybridized with multiwalled CNTs by drop-coating CNTs on graphenes. The supercapacitors using bare graphenes and graphenes with CNTs revealed that graphenes with CNTs resulted in enhanced supercapacitor performances of 2.2- (the mass-specific capacitance) and 4.4-fold (the area-specific capacitance) of those of bare graphenes. Our strategy to improve electrochemical performance of CVD-grown graphenes is advantageous for large-scale graphene electrodes due to high electrical conductivity of CVD-grown graphenes and cost-effectiveness of using multiwalled CNTs as compared to conventional employment of single-walled CNTs

  8. Deposition and micro electrical discharge machining of CVD-diamond layers incorporated with silicon

    Science.gov (United States)

    Kühn, R.; Berger, T.; Prieske, M.; Börner, R.; Hackert-Oschätzchen, M.; Zeidler, H.; Schubert, A.

    2017-10-01

    In metal forming, lubricants have to be used to prevent corrosion or to reduce friction and tool wear. From an economical and ecological point of view, the aim is to avoid the usage of lubricants. For dry deep drawing of aluminum sheets it is intended to apply locally micro-structured wear-resistant carbon based coatings onto steel tools. One type of these coatings are diamond layers prepared by chemical vapor deposition (CVD). Due to the high strength of diamond, milling processes are unsuitable for micro-structuring of these layers. In contrast to this, micro electrical discharge machining (micro EDM) is a suitable process for micro-structuring CVD-diamond layers. Due to its non-contact nature and its process principle of ablating material by melting and evaporating, it is independent of the hardness, brittleness or toughness of the workpiece material. In this study the deposition and micro electrical discharge machining of silicon incorporated CVD-diamond (Si-CVD-diamond) layers were presented. For this, 10 µm thick layers were deposited on molybdenum plates by a laser-induced plasma CVD process (LaPlas-CVD). For the characterization of the coatings RAMAN- and EDX-analyses were conducted. Experiments in EDM were carried out with a tungsten carbide tool electrode with a diameter of 90 µm to investigate the micro-structuring of Si-CVD-diamond. The impact of voltage, discharge energy and tool polarity on process speed and resulting erosion geometry were analyzed. The results show that micro EDM is a suitable technology for micro-structuring of silicon incorporated CVD-diamond layers.

  9. Bone repair after osteotomy with diamond burs and CVD ultrasonic tips – histological study in rats

    OpenAIRE

    Matuda, Fábio S.; Pagani, Clovis; Miranda, Carolina B.; Crema, Aline A. S.; Brentel, Aline S.; Carvalho, Yasmin R.

    2010-01-01

    This study histologically evaluated the behavior of bone tissue of rats submitted to osteotomy with conventional diamond burs in high speed and a new ultrasonic diamond tips system (CVD – Chemical Vapor Deposition), at different study periods. The study was conducted on 24 Wistar rats. Osteotomy was performed on the posterior paws of each rat, with utilization of diamond burs in high speed under thorough water cooling at the right paw, and CVD tips at the left paw. Animals were killed a...

  10. Simulation of a perfect CVD diamond Schottky diode steep forward current–voltage characteristic

    Energy Technology Data Exchange (ETDEWEB)

    Kukushkin, V.A., E-mail: vakuk@appl.sci-nnov.ru [Institute of Applied Physics of the Russian Academy of Science, 46 Ulyanov St., 603950 Nizhny Novgorod (Russian Federation); Nizhny Novgorod State University named after N.I. Lobachevsky, 23 Gagarin pr., 603950 Nizhny Novgorod (Russian Federation)

    2016-10-01

    The kinetic equation approach to the simulation of the perfect CVD diamond Schottky diode current–voltage characteristic is considered. In result it is shown that the latter has a significantly steeper forward branch than that of perfect devices of such a type on usual semiconductors. It means that CVD diamond-based Schottky diodes have an important potential advantage over analogous devices on conventional materials.

  11. Tribological Characteristics and Applications of Superhard Coatings: CVD Diamond, DLC, and c-BN

    Science.gov (United States)

    Miyoshi, Kazuhisa; Murakawa, Masao; Watanabe, Shuichi; Takeuchi, Sadao; Wu, Richard L. C.

    1999-01-01

    Results of fundamental research on the tribological properties of chemical-vapor-deposited (CVD) diamond, diamondlike carbon, and cubic boron nitride films in sliding contact with CVD diamond in ultrahigh vacuum, dry nitrogen, humid air, and water are discussed. Furthermore, the actual and potential applications of the three different superhard coatings in the field of tribology technology, particularly for wear parts and tools, are reviewed.

  12. CVD Diamond, DLC, and c-BN Coatings for Solid Film Lubrication

    Science.gov (United States)

    Miyoshi, Kazuhisa

    1998-01-01

    When the main criteria for judging coating performance were coefficient of friction and wear rate, which had to be less than 0.1 and 10(exp -6) mm(exp 3)/N-m, respectively, carbon- and nitrogen-ion-implanted, fine-grain CVD diamond and DLC ion beam deposited on fine-grain CVD diamond met the requirements regardless of environment (vacuum, nitrogen, and air).

  13. Chemical vapor deposition (CVD) of uranium for alpha spectrometry; Deposicion quimica de vapor (CVD) de uranio para espectrometria alfa

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez V, M. L.; Rios M, C.; Ramirez O, J.; Davila R, J. I.; Mireles G, F., E-mail: luisalawliet@gmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2015-09-15

    The uranium determination through radiometric techniques as alpha spectrometry requires for its proper analysis, preparation methods of the source to analyze and procedures for the deposit of this on a surface or substrate. Given the characteristics of alpha particles (small penetration distance and great loss of energy during their journey or its interaction with the matter), is important to ensure that the prepared sources are thin, to avoid problems of self-absorption. The routine methods used for this are the cathodic electro deposition and the direct evaporation, among others. In this paper the use of technique of chemical vapor deposition (CVD) for the preparation of uranium sources is investigated; because by this, is possible to obtain thin films (much thinner than those resulting from electro deposition or evaporation) on a substrate and comprises reacting a precursor with a gas, which in turn serves as a carrier of the reaction products to achieve deposition. Preliminary results of the chemical vapor deposition of uranium are presented, synthesizing and using as precursor molecule the uranyl acetylacetonate, using oxygen as carrier gas for the deposition reaction on a glass substrate. The uranium films obtained were found suitable for alpha spectrometry. The variables taken into account were the precursor sublimation temperatures and deposition temperature, the reaction time and the type and flow of carrier gas. Of the investigated conditions, two depositions with encouraging results that can serve as reference for further work to improve the technique presented here were selected. Alpha spectra obtained for these depositions and the characterization of the representative samples by scanning electron microscopy and X-ray diffraction are also presented. (Author)

  14. Surface structuring of boron doped CVD diamond by micro electrical discharge machining

    Science.gov (United States)

    Schubert, A.; Berger, T.; Martin, A.; Hackert-Oschätzchen, M.; Treffkorn, N.; Kühn, R.

    2018-05-01

    Boron doped diamond materials, which are generated by Chemical Vapor Deposition (CVD), offer a great potential for the application on highly stressed tools, e. g. in cutting or forming processes. As a result of the CVD process rough surfaces arise, which require a finishing treatment in particular for the application in forming tools. Cutting techniques such as milling and grinding are hardly applicable for the finish machining because of the high strength of diamond. Due to its process principle of ablating material by melting and evaporating, Electrical Discharge Machining (EDM) is independent of hardness, brittleness or toughness of the workpiece material. EDM is a suitable technology for machining and structuring CVD diamond, since boron doped CVD diamond is electrically conductive. In this study the ablation characteristics of boron doped CVD diamond by micro electrical discharge machining are investigated. Experiments were carried out to investigate the influence of different process parameters on the machining result. The impact of tool-polarity, voltage and discharge energy on the resulting erosion geometry and the tool wear was analyzed. A variation in path overlapping during the erosion of planar areas leads to different microstructures. The results show that micro EDM is a suitable technology for finishing of boron doped CVD diamond.

  15. A Hybrid Information Mining Approach for Knowledge Discovery in Cardiovascular Disease (CVD

    Directory of Open Access Journals (Sweden)

    Stefania Pasanisi

    2018-04-01

    Full Text Available The healthcare ambit is usually perceived as “information rich” yet “knowledge poor”. Nowadays, an unprecedented effort is underway to increase the use of business intelligence techniques to solve this problem. Heart disease (HD is a major cause of mortality in modern society. This paper analyzes the risk factors that have been identified in cardiovascular disease (CVD surveillance systems. The Heart Care study identifies attributes related to CVD risk (gender, age, smoking habit, etc. and other dependent variables that include a specific form of CVD (diabetes, hypertension, cardiac disease, etc.. In this paper, we combine Clustering, Association Rules, and Neural Networks for the assessment of heart-event-related risk factors, targeting the reduction of CVD risk. With the use of the K-means algorithm, significant groups of patients are found. Then, the Apriori algorithm is applied in order to understand the kinds of relations between the attributes within the dataset, first looking within the whole dataset and then refining the results through the subsets defined by the clusters. Finally, both results allow us to better define patients’ characteristics in order to make predictions about CVD risk with a Multilayer Perceptron Neural Network. The results obtained with the hybrid information mining approach indicate that it is an effective strategy for knowledge discovery concerning chronic diseases, particularly for CVD risk.

  16. Ion beam induced surface graphitization of CVD diamond for x-ray beam position monitor applications

    International Nuclear Information System (INIS)

    Liu, Chian; Shu, D.; Kuzay, T.M.; Wen, L.; Melendres, C.A.; Argonne National Lab., IL

    1996-01-01

    The Advanced Photon Source at ANL is a third-generation synchrotron facility that generates powerful x-ray beams on its undulator beamlines. It is important to know the position and angle of the x- ray beam during experiments. Due to very high heat flux levels, several patented x-ray beam position monitors (XBPM) exploiting chemical vapor deposition (CVD) diamond have been developed. These XBPMs have a thin layer of low-atomic-mass metallic coating so that photoemission from the x rays generate a minute but measurable current for position determination. Graphitization of the CVD diamond surface creates a very thin, intrinsic and conducting layer that can stand much higher temperatures and minimal x-ray transmission losses compared to the coated metallic layers. In this paper, a laboratory sputter ion source was used to transform selected surfaces of a CVD diamond substrate into graphite. The effect of 1-5 keV argon ion bombardment on CVD diamond surfaces at various target temperatures from 200 to 500 C was studied using Auger electron spectroscopy and in-situ electrical resistivity measurements. Graphitization after the ion bombardment has been confirmed and optimum conditions for graphitization studied. Raman spectroscopy was used to identify the overall diamond structure in the bulk of CVD diamond substrate after the ion bombardments. It was found that target temperature plays an important role in stability and electrical conductivity of the irradiated CVD diamonds

  17. Diabetic retinopathy is associated with mortality and cardiovascular disease incidence: the EURODIAB prospective complications study

    NARCIS (Netherlands)

    van Hecke, M.V.; Dekker, J.M.; Stehouwer, C.D.A.; Polak, B.C.P.; Fuller, J.H.; Sjolie, A.K.; Kofinis, A.; Rottiers, R.; Porta, M.; Chaturvedi, N.

    2005-01-01

    OBJECTIVE - To study the relationship of nonproliferative and proliferative retinopathy with all-cause mortality and cardiovascular disease (CVD) incidence in type 1 diabetic patients and, additionally, the role of cardiovascular risk factors in these associations. RESEARCH DESIGN AND METHODS - This

  18. Mediterranean Style Diet and 12-Year Incidence of Cardiovascular Diseases: The Epic-NL Cohort Stusy

    NARCIS (Netherlands)

    Hoevenaar-Blom, M.P.; Nooyens, A.J.C.; Kromhout, D.; Spijkerman, A.M.W.; Beulens, W.J.; Schouw, van der Y.T.; Bueno-de-Mesquita4, B.; Verschuren, W.M.M.

    2012-01-01

    Background: A recent meta-analysis showed that a Mediterranean style diet may protect against cardiovascular diseases (CVD). Studies on disease-specific associations are limited. We evaluated the Mediterranean Diet Score (MDS) in relation to incidence of total and specific CVDs. Methods: The EPIC-NL

  19. Cardiovascular disease (CVD) and chronic kidney disease (CKD) event rates in HIV-positive persons at high predicted CVD and CKD risk

    DEFF Research Database (Denmark)

    Boyd, Mark A; Mocroft, Amanda; Ryom, Lene

    2017-01-01

    BACKGROUND: The Data Collection on Adverse Events of Anti-HIV Drugs (D:A:D) study has developed predictive risk scores for cardiovascular disease (CVD) and chronic kidney disease (CKD, defined as confirmed estimated glomerular filtration rate [eGFR] ≤ 60 ml/min/1.73 m2) events in HIV...

  20. How dietary evidence for the prevention and treatment of CVD is translated into practice in those with or at high risk of CVD: a systematic review.

    Science.gov (United States)

    Schumacher, Tracy L; Burrows, Tracy L; Neubeck, Lis; Redfern, Julie; Callister, Robin; Collins, Clare E

    2017-01-01

    CVD is a leading cause of mortality and morbidity, and nutrition is an important lifestyle factor. The aim of the present systematic review was to synthesise the literature relating to knowledge translation (KT) of dietary evidence for the prevention and treatment of CVD into practice in populations with or at high risk of CVD. A systematic search of six electronic databases (CINAHL, Cochrane, EMBASE, MEDLINE, PsycINFO and Scopus) was performed. Studies were included if a nutrition or dietary KT was demonstrated to occur with a relevant separate measureable outcome. Quality was assessed using a tool adapted from two quality checklists. Population with or at high risk of CVD or clinicians likely to treat this population. A total of 4420 titles and abstracts were screened for inclusion, with 354 full texts retrieved to assess inclusion. Forty-three articles were included in the review, relating to thirty-five separate studies. No studies specifically stated their aim to be KT. Thirty-one studies were in patient or high-risk populations and four targeted health professionals. Few studies stated a theory on which the intervention was based (n 10) and provision of instruction was the most common behaviour change strategy used (n 26). KT in nutrition and dietary studies has been inferred, not stated, with few details provided regarding how dietary knowledge is translated to the end user. This presents challenges for implementation by clinicians and policy and decision makers. Consequently a need exists to improve the quality of publications in this area.

  1. A cost-benefit analysis of programmatic use of CVD 103-HgR live oral cholera vaccine in a high-risk population.

    Science.gov (United States)

    Cookson, S T; Stamboulian, D; Demonte, J; Quero, L; Martinez de Arquiza, C; Aleman, A; Lepetic, A; Levine, M M

    1997-02-01

    Cholera spread to Latin America in 1991; subsequently, cholera vaccination was considered as an interim intervention until long-term solutions involving improved water supplies and sanitation could be introduced. Three successive summer cholera outbreaks in northern Argentina and the licensing of the new single-dose oral cholera vaccine, CVD 103-HgR, raised questions of the cost and benefit of using this new vaccine. This study explored the potential benefits to the Argentine Ministry of Health of treatment costs averted, versus the costs of vaccination with CVD 103-HgR in the relatively confined population of northern Argentina affected by the cholera outbreaks. Water supplies and sanitation in this area are poor but a credible infrastructure for vaccine delivery exists. In our cost-benefit model of a 3-year period (1992-1994) with an annual incidence of 2.5 case-patients per 1000 population and assumptions of vaccine efficacy of 75% and coverage of 75%, vaccination of targeted high risk groups would prevent 1265 cases. Assuming a cost of US$602 per treated case and of US$1.50 per dose of vaccine, the total discounted savings from use of vaccine in the targeted groups would be US$132,100. The projected savings would be altered less by vaccine coverage (range 75-90%) or efficacy (60-85%) changes than by disease incidence changes. Our analysis underestimated the true costs of cholera in Argentina because we included only medical expenditures; Indirect losses to trade and tourism had the greatest economic impact. However, vaccination with CVD 103-HgR was still cost-beneficial in the base case.

  2. Socioeconomic variation in incidence of primary and secondary major cardiovascular disease events: an Australian population-based prospective cohort study.

    Science.gov (United States)

    Korda, Rosemary J; Soga, Kay; Joshy, Grace; Calabria, Bianca; Attia, John; Wong, Deborah; Banks, Emily

    2016-11-21

    Cardiovascular disease (CVD) disproportionately affects disadvantaged people, but reliable quantitative evidence on socioeconomic variation in CVD incidence in Australia is lacking. This study aimed to quantify socioeconomic variation in rates of primary and secondary CVD events in mid-age and older Australians. Baseline data (2006-2009) from the 45 and Up Study, an Australian cohort involving 267,153 men and women aged ≥ 45, were linked to hospital and death data (to December 2013). Outcomes comprised first event - death or hospital admission - for major CVD combined, as well as myocardial infarction and stroke, in those with and without prior CVD (secondary and primary events, respectively). Cox regression estimated hazard ratios (HRs) for each outcome in relation to education (and income and area-level disadvantage), separately by age group (45-64, 65-79, and ≥ 80 years), adjusting for age and sex, and additional sociodemographic factors. There were 18,207 primary major CVD events over 1,144,845 years of follow-up (15.9/1000 person-years), and 20,048 secondary events over 260,357 years (77.0/1000 person-years). For both primary and secondary events, incidence increased with decreasing education, with the absolute difference between education groups largest for secondary events. Age-sex adjusted hazard ratios were highest in the 45-64 years group: for major CVDs, HR (no qualifications vs university degree) = 1.62 (95% CI: 1.49-1.77) for primary events, and HR = 1.49 (1.34-1.65) for secondary events; myocardial infarction HR = 2.31 (1.87-2.85) and HR = 2.57 (1.90-3.47) respectively; stroke HR = 1.48 (1.16-1.87) and HR = 1.97 (1.42-2.74) respectively. Similar but attenuated results were seen in older age groups, and with income. For area-level disadvantage, CVD gradients were weak and non-significant in older people (> 64 years). Individual-level data are important for quantifying socioeconomic variation in CVD incidence, which

  3. Proposed classification scale for radiological incidents and accidents

    International Nuclear Information System (INIS)

    2003-04-01

    The scale proposed in this report is intended to facilitate communication concerning the severity of incidents and accidents involving the exposure of human beings to ionising radiations. Like the INES, it comprises eight levels of severity and uses the same terms (accident, incident, anomaly, serious and major) for keeping the public and the media informed. In a radiological protection context, the severity of an event is considered as being directly proportional to the risk run by an individual (the probability of developing fatal or non-fatal health effects) following exposure to ionising radiation in an incident or accident situation. However for society, other factors have to be taken into account to determine severity. The severity scale proposed is therefore based on assessment of the individual radiological risk. A severity level corresponding to exposure of a member of the public in an incident or accident situation is determined on the basis of risk assessment concepts and methods derived from international consensus on dose/effect relationships for both stochastic and deterministic effects. The severity of all the possible exposure situations - worker exposure, collective exposure, potential exposure - is determined using a system of weighting in relation to situations involving members of the public. In the case of this scale, to indicate the severity of an event, it is proposed to make use of the most penalizing level of severity, comparing: - the severity associated with the probability of occurrence of deterministic effects and the severity associated with the probability of occurrence of stochastic effects, when the event gives rise to both types of risk; - the severity for members of the public and the severity for exposed workers, when both categories of individuals are involved; - the severity on the proposed radiological protection scale and that obtained using the INES, when radiological protection and nuclear safety aspects are associated with

  4. Friction Properties of Polished Cvd Diamond Films Sliding against Different Metals

    Science.gov (United States)

    Lin, Zichao; Sun, Fanghong; Shen, Bin

    2016-11-01

    Owing to their excellent mechanical and tribological properties, like the well-known extreme hardness, low coefficient of friction and high chemical inertness, chemical vapor deposition (CVD) diamond films have found applications as a hard coating for drawing dies. The surface roughness of the diamond films is one of the most important attributes to the drawing dies. In this paper, the effects of different surface roughnesses on the friction properties of diamond films have been experimentally studied. Diamond films were fabricated using hot filament CVD. The WC-Co (Co 6wt.%) drawing dies were used as substrates. A gas mixture of acetone and hydrogen gas was used as the feedstock gas. The CVD diamond films were polished using mechanical polishing. Polished diamond films with three different surface roughnesses, as well as the unpolished diamond film, were fabricated in order to study the tribological performance between the CVD diamond films and different metals with oil lubrication. The unpolished and polished CVD diamond films are characterized with scanning electron microscope (SEM), atomic force microscope (AFM), surface profilometer, Raman spectrum and X-ray diffraction (XRD). The friction examinations were carried out by using a ball-on-plate type reciprocating friction tester. Low carbide steel, stainless steel, copper and aluminum materials were used as counterpart balls. Based on this study, the results presented the friction coefficients between the polished CVD films and different metals. The friction tests demonstrate that the smooth surface finish of CVD diamond films is beneficial for reducing their friction coefficients. The diamond films exhibit low friction coefficients when slid against the stainless steel balls and low carbide steel ball, lower than that slid against copper ball and aluminum ball, attributed to the higher ductility of copper and aluminum causing larger amount of wear debris adhering to the sliding interface and higher adhesive

  5. Cardiovascular disease (CVD and chronic kidney disease (CKD event rates in HIV-positive persons at high predicted CVD and CKD risk: A prospective analysis of the D:A:D observational study.

    Directory of Open Access Journals (Sweden)

    Mark A Boyd

    2017-11-01

    Full Text Available The Data Collection on Adverse Events of Anti-HIV Drugs (D:A:D study has developed predictive risk scores for cardiovascular disease (CVD and chronic kidney disease (CKD, defined as confirmed estimated glomerular filtration rate [eGFR] ≤ 60 ml/min/1.73 m2 events in HIV-positive people. We hypothesized that participants in D:A:D at high (>5% predicted risk for both CVD and CKD would be at even greater risk for CVD and CKD events.We included all participants with complete risk factor (covariate data, baseline eGFR > 60 ml/min/1.73 m2, and a confirmed (>3 months apart eGFR 1%-5%, >5% and fitted Poisson models to assess whether CVD and CKD risk group effects were multiplicative. A total of 27,215 participants contributed 202,034 person-years of follow-up: 74% male, median (IQR age 42 (36, 49 years, median (IQR baseline year of follow-up 2005 (2004, 2008. D:A:D risk equations predicted 3,560 (13.1% participants at high CVD risk, 4,996 (18.4% participants at high CKD risk, and 1,585 (5.8% participants at both high CKD and high CVD risk. CVD and CKD event rates by predicted risk group were multiplicative. Participants at high CVD risk had a 5.63-fold (95% CI 4.47, 7.09, p < 0.001 increase in CKD events compared to those at low risk; participants at high CKD risk had a 1.31-fold (95% CI 1.09, 1.56, p = 0.005 increase in CVD events compared to those at low risk. Participants' CVD and CKD risk groups had multiplicative predictive effects, with no evidence of an interaction (p = 0.329 and p = 0.291 for CKD and CVD, respectively. The main study limitation is the difference in the ascertainment of the clinically defined CVD endpoints and the laboratory-defined CKD endpoints.We found that people at high predicted risk for both CVD and CKD have substantially greater risks for both CVD and CKD events compared with those at low predicted risk for both outcomes, and compared to those at high predicted risk for only CVD or CKD events. This suggests that CVD and

  6. Prospective association of the Mediterranean diet with cardiovascular disease incidence and mortality and its population impact in a non-Mediterranean population: the EPIC-Norfolk study.

    Science.gov (United States)

    Tong, Tammy Y N; Wareham, Nicholas J; Khaw, Kay-Tee; Imamura, Fumiaki; Forouhi, Nita G

    2016-09-29

    Despite convincing evidence in the Mediterranean region, the cardiovascular benefit of the Mediterranean diet is not well established in non-Mediterranean countries and the optimal criteria for defining adherence are unclear. The population attributable fraction (PAF) of adherence to this diet is also unknown. In the UK-based EPIC-Norfolk prospective cohort, we evaluated habitual diets assessed at baseline (1993-1997) and during follow-up (1998-2000) using food-frequency questionnaires (n = 23,902). We estimated a Mediterranean diet score (MDS) using cut-points projected from the Mediterranean dietary pyramid, and also three other pre-existing MDSs. Using multivariable-adjusted Cox regression with repeated measures of MDS and covariates, we examined prospective associations between each MDS with incident cardiovascular diseases (CVD) by 2009 and mortality by 2013, and estimated PAF for each outcome attributable to low MDS. We observed 7606 incident CVD events (2818/100,000 person-years) and 1714 CVD deaths (448/100,000). The MDS based on the Mediterranean dietary pyramid was significantly associated with lower incidence of the cardiovascular outcomes, with hazard ratios (95 % confidence intervals) of 0.95 (0.92-0.97) per one standard deviation for incident CVD and 0.91 (0.87-0.96) for CVD mortality. Associations were similar for composite incident ischaemic heart disease and all-cause mortality. Other pre-existing MDSs showed similar, but more modest associations. PAF due to low dietary pyramid based MDS (Mediterranean diet was associated with lower CVD incidence and mortality in the UK. This diet has an important population health impact for the prevention of CVD.

  7. The Mediterranean diet in relation to mortality and CVD

    DEFF Research Database (Denmark)

    Tognon, G.; Lissner, L.; Saebye, D.

    2014-01-01

    The aim of the present study was to determine whether the Mediterranean Diet Score (MDS) is associated with reduced total mortality, cardiovascular incidence and mortality in a Danish population. Analyses were performed on 1849 men and women sampled during the 1982-83 Danish MONICA (MONItoring...... trends and determinants of Cardiovascular disease) population study, whose diet was assessed by means of a validated 7d food record. The adherence to a Mediterranean dietary pattern was calculated by three different scores: one based on a classification excluding ingredients from mixed dishes and recipes...

  8. Tribosystems based on multilayered micro/nanocrystalline CVD diamond coatings =

    Science.gov (United States)

    Shabani, Mohammadmehdi

    A combinacao das caracteristicas do diamante microcristalino (MCD) e nanocristalino (NCD), tais como elevada adesao do MCD e a baixa rugosidade superficial e baixo coeficiente de atrito do NCD, e ideal para aplicacoes tribologicas exigentes. Deste modo, o presente trabalho centrou-se no desenvolvimento de revestimentos em multicamada MCD/NCD. Filmes com dez camadas foram depositados em amostras de cerâmicos de Si3N4 pela tecnica de deposicao quimica em fase vapor assistida por filamento quente (HFCVD). A microestrutura, qualidade do diamante e adesao foram investigadas usando tecnicas como SEM, AFM, espectroscopia Raman, DRX, indentacao Brale e perfilometria otica 3D. Diversas geometrias para aplicacoes distintas foram revestidas: discos e esferas para testes tribologicos a escala laboratorial, e para testes em servico, aneis de empanques mecânicos e pastilhas de corte para torneamento. Nos ensaios tribologicos esfera-sobre-plano em movimento reciproco, sob 10-90% de humidade relativa (RH), os valores medios dos coeficientes de atrito maximo e em estado estacionario sao de 0,32 e 0,09, respetivamente. Em relacao aos coeficientes de desgaste, observou-se um valor minimo de cerca de 5,2x10-8 mm3N-1m-1 para valores intermedios de 20-25% de RH. A humidade relativa tem um forte efeito sobre o valor da carga critica que triplica a partir de 40 N a 10% RH para 120 N a 90% de RH. No intervalo de temperaturas 50-100 °C, as cargas criticas sao semelhantes as obtidas em condicoes de baixa RH ( 10-25%). A vida util das ferramentas com revestimento de dez camadas alternadas MCD/NCD e 24 mum de espessura total no torneamento de um composito de matriz metalica Al- 15 vol% Al2O3 (Al-MMC) e melhor do que a maioria das ferramentas de diamante CVD encontradas na literatura, e semelhante a maioria das ferramentas de diamante policristalino (PCD). A formacao de cratera ocorre por desgaste sucessivo das varias camadas, atrasando a delaminacao total do revestimento de diamante do

  9. Association of anxiety disorders and depression with incident heart failure.

    Science.gov (United States)

    Garfield, Lauren D; Scherrer, Jeffrey F; Hauptman, Paul J; Freedland, Kenneth E; Chrusciel, Tim; Balasubramanian, Sumitra; Carney, Robert M; Newcomer, John W; Owen, Richard; Bucholz, Kathleen K; Lustman, Patrick J

    2014-02-01

    Depression has been associated with increased risk of heart failure (HF). Because anxiety is highly comorbid with depression, we sought to establish if anxiety, depression, or their co-occurrence is associated with incident HF. A retrospective cohort (N = 236,079) including Veteran's Administration patients (age, 50-80 years) free of cardiovascular disease (CVD) at baseline was followed up between 2001 and 2007. Cox proportional hazards models were computed to estimate the association between anxiety disorders alone, major depressive disorder (MDD) alone, and the combination of anxiety and MDD, with incident HF before and after adjusting for sociodemographics, CVD risk factors (Type 2 diabetes, hypertension, hyperlipidemia, obesity), nicotine dependence/personal history of tobacco use, substance use disorders (alcohol and illicit drug abuse/dependence), and psychotropic medication. Compared with unaffected patients, those with anxiety only, MDD only, and both disorders were at increased risk for incident HF in age-adjusted models (hazard ratio [HR] = 1.19 [ 95% confidence interval {CI} = 1.10-1.28], HR = 1.21 [95% CI = 1.13-1.28], and HR = 1.24 [95% CI = 1.17-1.32], respectively). After controlling for psychotropics in a full model, the association between anxiety only, MDD only, and both disorders and incident HF increased (HRs = 1.46, 1.56, and 1.74, respectively). Anxiety disorders, MDD, and co-occurring anxiety and MDD are associated with incident HF in this large cohort of Veteran's Administration patients free of CVD at baseline. This risk of HF is greater after accounting for protective effects of psychotropic medications. Prospective studies are needed to clarify the role of depression and anxiety and their pharmacological treatment in the etiology of HF.

  10. Movers and stayers: The geography of residential mobility and CVD hospitalisations in Auckland, New Zealand.

    Science.gov (United States)

    Exeter, Daniel J; Sabel, Clive E; Hanham, Grant; Lee, Arier C; Wells, Susan

    2015-05-01

    The association between area-level disadvantage and health and social outcomes is unequivocal. However, less is known about the health impact of residential mobility, particularly at intra-urban scales. We used an encrypted National Health Index (eNHI) number to link individual-level data recorded in routine national health databases to construct a cohort of 641,532 participants aged 30+ years to investigate the association between moving and CVD hospitalisations in Auckland, New Zealand. Residential mobility was measured for participants according to changes in the census Meshblock of usual residence, obtained from the Primary Health Organisation (PHO) database for every calendar quarter between 1/1/2006 and 31/12/2012. The NZDep2006 area deprivation score at the start and end of a participant's inclusion in the study was used to measure deprivation mobility. We investigated the relative risk of movers being hospitalised for CVD relative to stayers using multi-variable binomial regression models, controlling for age, gender, deprivation and ethnicity. Considered together, movers were 1.22 (1.19-1.26) times more likely than stayers to be hospitalised for CVD. Using the 5×5 deprivation origin-destination matrix to model a patient's risk of CVD based on upward, downward or sideways deprivation mobility, movers within the least deprived (NZDep2006 Quintile 1) areas were 10% less likely than stayers to be hospitalised for CVD, while movers within the most deprived (NZDep2006 Q5) areas were 45% more likely than stayers to have had their first CVD hospitalisation in 2006-2012 (RR: 1.45 [1.35-1.55]). Participants who moved upward also had higher relative risks of having a CVD event, although their risk was less than those observed for participants experiencing downward deprivation mobility. This research suggests that residential mobility is an important determinant of CVD in Auckland. Further investigation is required to determine the impact moving has on the risk of

  11. Rapid growth of single-layer graphene on the insulating substrates by thermal CVD

    Energy Technology Data Exchange (ETDEWEB)

    Chen, C.Y. [Faculty of Materials Science and Engineering, Kunming University of Science and Technology, Kunming 650093 (China); Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Dai, D.; Chen, G.X.; Yu, J.H. [Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Nishimura, K. [Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Advanced Nano-processing Engineering Lab, Mechanical Systems Engineering, Kogakuin University (Japan); Lin, C.-T. [Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Jiang, N., E-mail: jiangnan@nimte.ac.cn [Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Zhan, Z.L., E-mail: zl_zhan@sohu.com [Faculty of Materials Science and Engineering, Kunming University of Science and Technology, Kunming 650093 (China)

    2015-08-15

    Highlights: • A rapid thermal CVD process has been developed to directly grow graphene on the insulating substrates. • The treating time consumed is ≈25% compared to conventional CVD procedure. • Single-layer and few-layer graphene can be formed on quartz and SiO{sub 2}/Si substrates, respectively. • The formation of thinner graphene at the interface is due to the fast precipitation rate of carbon atoms during cooling. - Abstract: The advance of CVD technique to directly grow graphene on the insulating substrates is particularly significant for further device fabrication. As graphene is catalytically grown on metal foils, the degradation of the sample properties is unavoidable during transfer of graphene on the dielectric layer. Moreover, shortening the treatment time as possible, while achieving single-layer growth of graphene, is worthy to be investigated for promoting the efficiency of mass production. Here we performed a rapid heating/cooling process to grow graphene films directly on the insulating substrates by thermal CVD. The treating time consumed is ≈25% compared to conventional CVD procedure. In addition, we found that high-quality, single-layer graphene can be formed on quartz, but on SiO{sub 2}/Si substrate only few-layer graphene can be obtained. The pronounced substrate effect is attributed to the different dewetting behavior of Ni films on the both substrates at 950 °C.

  12. Applicability of the Existing CVD Risk Assessment Tools to Type II Diabetics in Oman: A Review

    Directory of Open Access Journals (Sweden)

    Abdulhakeem Al-Rawahi

    2015-09-01

    Full Text Available Patients with type II diabetes (T2DM have an elevated risk for cardiovascular disease (CVD, and it is considered to be a leading cause of morbidity and premature mortality in these patients. Many traditional risk factors such as age, male sex, hypertension, dyslipidemia, glycemic control, diabetes duration, renal dysfunction, obesity, and smoking have been studied and identified as independent factors for CVD. Quantifying the risk of CVD among diabetics using the common risk factors in order to plan the treatment and preventive measures is important in the management of these patients as recommended by many clinical guidelines. Therefore, several risk assessment tools have been developed in different parts of the world for this purpose. These include the tools that have been developed for general populations and considered T2DM as a risk factor, and the tools that have been developed for T2DM populations specifically. However, due to the differences in sociodemographic factors and lifestyle patterns, as well as the differences in the distribution of various CVD risk factors in different diabetic populations, the external applicability of these tools on different populations is questionable. This review aims to address the applicability of the existing CVD risk models to the Omani diabetic population.

  13. Reference Intervals for Non-Fasting CVD Lipids and Inflammation Markers in Pregnant Indigenous Australian Women.

    Science.gov (United States)

    Schumacher, Tracy L; Oldmeadow, Christopher; Clausen, Don; Weatherall, Loretta; Keogh, Lyniece; Pringle, Kirsty G; Rae, Kym M

    2017-10-14

    Indigenous Australians experience high rates of cardiovascular disease (CVD). The origins of CVD may commence during pregnancy, yet few serum reference values for CVD biomarkers exist specific to the pregnancy period. The Gomeroi gaaynggal research project is a program that undertakes research and provides some health services to pregnant Indigenous women. Three hundred and ninety-nine non-fasting samples provided by the study participants (206 pregnancies and 175 women) have been used to construct reference intervals for CVD biomarkers during this critical time. A pragmatic design was used, in that women were not excluded for the presence of chronic or acute health states. Percentile bands for non-linear relationships were constructed according to the methods of Wright and Royston (2008), using the xriml package in StataIC 13.1. Serum cholesterol, triglycerides, cystatin-C and alkaline phosphatase increased as gestational age progressed, with little change seen in high-sensitivity C-Reactive Protein and γ glutamyl transferase. Values provided in the reference intervals are consistent with findings from other research projects. These reference intervals will form a basis with which future CVD biomarkers for pregnant Indigenous Australian women can be compared.

  14. Spin transport in two-layer-CVD-hBN/graphene/hBN heterostructures

    Science.gov (United States)

    Gurram, M.; Omar, S.; Zihlmann, S.; Makk, P.; Li, Q. C.; Zhang, Y. F.; Schönenberger, C.; van Wees, B. J.

    2018-01-01

    We study room-temperature spin transport in graphene devices encapsulated between a layer-by-layer-stacked two-layer-thick chemical vapor deposition (CVD) grown hexagonal boron nitride (hBN) tunnel barrier, and a few-layer-thick exfoliated-hBN substrate. We find mobilities and spin-relaxation times comparable to that of SiO2 substrate-based graphene devices, and we obtain a similar order of magnitude of spin relaxation rates for both the Elliott-Yafet and D'Yakonov-Perel' mechanisms. The behavior of ferromagnet/two-layer-CVD-hBN/graphene/hBN contacts ranges from transparent to tunneling due to inhomogeneities in the CVD-hBN barriers. Surprisingly, we find both positive and negative spin polarizations for high-resistance two-layer-CVD-hBN barrier contacts with respect to the low-resistance contacts. Furthermore, we find that the differential spin-injection polarization of the high-resistance contacts can be modulated by dc bias from -0.3 to +0.3 V with no change in its sign, while its magnitude increases at higher negative bias. These features point to the distinctive spin-injection nature of the two-layer-CVD-hBN compared to the bilayer-exfoliated-hBN tunnel barriers.

  15. Effect of pulse biasing on the morphology of diamond films grown by hot filament CVD

    International Nuclear Information System (INIS)

    Beake, B.D.; Hussain, I.U.; Rego, C.; Ahmed, W.

    1999-01-01

    There has been considerable interest in the chemical vapour deposition (CVD) of diamond due to its unique mechanical, optical and electronic properties, which make it useful for many applications. For use in optical and electronic applications further developments in the CVD process are required to control the surface morphology and crystal size of the diamond films. These will require a detailed understanding of both the nucleation and growth processes that effect the properties. The technique of bias enhanced nucleation (BEN) of diamond offers better reproducibility than conventional pre-treatment methods such as mechanical abrasion. Atomic force microscopy (AFM) and scanning electron microscopy (SEM) have been used study the surface modification of diamond films on silicon substrates during pulse biased growth in a hot filament CVD reactor. Pre-abraded silicon substrates were subjected to a three-step sequential growth process: (i) diamond deposition under standard CVD conditions, (ii) bias pre-treatment and (iii) deposition under standard conditions. The results show that the bias pre-treatment time is a critical parameter controlling the surface morphology and roughness of the diamond films deposited. Biasing reduces the surface roughness from 152 nm for standard CVD diamond to 68 nm for the 2.5 minutes pulse biased film. Further increase in the bias time results in an increase in surface roughness and crystallite size. (author)

  16. Flavonoids and Reduction of Cardiovascular Disease (CVD) in Chronic Obstructive Pulmonary Disease (COPD).

    Science.gov (United States)

    Russo, Patrizia; Prinzi, Giulia; Lamonaca, Palma; Cardaci, Vittorio; Fini, Massimo

    2018-05-13

    Chronic obstructive pulmonary disease (COPD) and cardiovascular diseases (CV) often coexist. COPD and CVD are complex diseases characterized by a strict interaction between environment and genetic. The mechanisms linking these two diseases are complex, multifactorial and not entirely understood, influencing the therapeutic approach. COPD is characterized by several comorbidities, it is hypothesizable that treatment of cardiovascular co-morbidities may reduce morbidity and mortality. Flavonoids are an important class of plant low molecular weight secondary metabolites (SMs). Convincing data from laboratory, epidemiological, and human clinical studies point to an important effects on CVD risk prevention. This review aims to provide up-to-date information on the ability of Flavonoids to reduce the CVD risk. Current studies support the potential of Flavonoids to prevent the risk of CVD. Well-designed clinical studies are suggested to evaluate advantages and limits of Flavonoids for managing CVD comorbidity in COPD. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  17. High quality aluminide and thermal barrier coatings deposition for new and service exposed parts by CVD techniques

    Energy Technology Data Exchange (ETDEWEB)

    Pedraza, F.; Tuohy, C.; Whelan, L.; Kennedy, A.D. [SIFCO Turbine Components, Carrigtwohill, Cork (Ireland)

    2004-07-01

    In this work, the performance of CVD aluminide coatings is compared to that of coatings deposited by the classical pack cementation technique using standard SIFCO procedures. The CVD coatings always seem to behave better upon exposure to isothermal and cyclic oxidation conditions. This is explained by a longer term stability of CVD coatings, with higher Al amounts in the diffusion zone and less refractory element precipitation in the additive layer. The qualities of Pt/Al coatings by out-of-pack and CVD are also compared as a previous step for further thermal barrier coating deposition. As an example, YSZ thermal barrier coatings are deposited by MO-CVD on Pt/Al CVD bond coats rendering adherent and thick coatings around the surface of turbine blades. This process under development does not require complex manipulation of the component to be coated. (orig.)

  18. Incident diabetes mellitus, hypertension, and cardiovascular disease risk in exercising hypercholesterolemic patients.

    Science.gov (United States)

    Williams, Paul T; Franklin, Barry A

    2015-11-15

    Exercise may be an important treatment for hypercholesterolemic patients, particularly in statin users who are at increased diabetes risk. We therefore used Cox proportional hazard analyses to compare running and walking dose (metabolic equivalent hours/day [MET-h/d]) to diabetes, hypertension, and cardiovascular disease (CVD) risk in hypercholesterolemic patients. There were 60 diabetic- and 373 CVD-related deaths during a 10.1-year mortality surveillance of 6,688 hypercholesterolemic patients. In addition, there were 177 incident nonfatal diabetes, 815 incident nonfatal hypertensions, and 323 incident nonfatal CVD events during a 6.4-year follow-up of 6,971 hypercholesterolemic patients who supplied follow-up questionnaires. Fatal and nonfatal diabetes risk decreased 26% (p = 0.002) and 19% (p ≤0.0001) per MET-h/d, respectively, and relative to hypertension risk decreased 4% (p = 0.01) per MET-h/d, and relative to diabetes, hypertension, and CVD risk in hypercholesterolemic patients and should more than compensate for the purported 9% increase in diabetes risk from statin use. By preventing morbidity and mortality for a specific existing medical condition, some exercise expenses may qualify for flexible spending account expenditures in hypercholesterolemic patients when prescribed by a physician. Published by Elsevier Inc.

  19. Electrical characteristics of thermal CVD B-doped Si films on highly strained Si epitaxially grown on Ge(100) by plasma CVD without substrate heating

    International Nuclear Information System (INIS)

    Sugawara, Katsutoshi; Sakuraba, Masao; Murota, Junichi

    2010-01-01

    Using an 84% relaxed Ge(100) buffer layer formed on Si(100) by electron cyclotron resonance (ECR) plasma enhanced chemical vapor deposition (CVD), influence of strain upon electrical characteristics of B-doped Si film epitaxially grown on the Ge buffer have been investigated. For the thinner B-doped Si film, surface strain amount is larger than that of the thicker film, for example, strain amount reaches 2.0% for the thickness of 2.2 nm. It is found that the hole mobility is enhanced by the introduction of strain to Si, and the maximum enhancement of about 3 is obtained. This value is higher than that of the usually reported mobility enhancement by strain using Si 1 -x Ge x buffer. Therefore, introduction of strain using relaxed Ge film formed by ECR plasma enhanced CVD is useful to improve future Si-based device performance.

  20. Resting heart rate and the incidence and progression of valvular calcium: The Multi-Ethnic Study of Atherosclerosis (MESA).

    Science.gov (United States)

    Amoakwa, Kojo; Fashanu, Oluwaseun E; Tibuakuu, Martin; Zhao, Di; Guallar, Eliseo; Whelton, Seamus P; O'Neal, Wesley T; Post, Wendy S; Budoff, Matthew J; Michos, Erin D

    2018-06-01

    Left-sided valvular calcification is associated with cardiovascular disease (CVD) morbidity and mortality. Resting heart rate (RHR) may influence valvular calcium progression through shear stress. Whether RHR, an established CVD risk factor, is associated with valvular calcium progression is unknown. We assessed whether RHR predicts incidence and progression of mitral annular calcium (MAC) and aortic valve calcium (AVC) in a community-based cohort free of CVD at baseline. RHR was obtained from baseline electrocardiograms of 5498 MESA participants. MAC and AVC were quantified using Agatston scoring from cardiac computed tomography scans obtained at baseline and at a second examination during follow-up. We examined associations of RHR with incident MAC/AVC and annual change in MAC/AVC scores, after adjusting for demographics, CVD risk factors, physical activity, and atrioventricular nodal blocker use. At baseline, participants had mean age of 62 ± 10 years and mean RHR of 63 ± 10 bpm; 12.3% and 8.9% had prevalent AVC and MAC, respectively. Over a median of 2.3 years, 4.1% and 4.5% developed incident AVC and MAC, respectively. Each 10 bpm higher RHR was significantly associated with incident MAC [Risk Ratio 1.17 (95% CI 1.03-1.34)], but not incident AVC. However, RHR was associated with AVC progression [β = 1.62 (0.45-2.80) Agatston units/year for every 10 bpm increment], but not MAC progression. Higher RHR was associated with MAC incidence and AVC progression, independent of traditional CVD risk factors. Future studies are needed to determine whether modification of RHR through lifestyle or pharmacologic interventions can reduce valvular calcium incidence or progression. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Non-classical crystallization of thin films and nanostructures in CVD and PVD processes

    CERN Document Server

    Hwang, Nong Moon

    2016-01-01

    This book provides a comprehensive introduction to a recently-developed approach to the growth mechanism of thin films and nanostructures via chemical vapour deposition (CVD). Starting from the underlying principles of the low pressure synthesis of diamond films, it is shown that diamond growth occurs not by individual atoms but by charged nanoparticles. This newly-discovered growth mechanism turns out to be general to many CVD and some physical vapor deposition (PVD) processes. This non-classical crystallization is a new paradigm of crystal growth, with active research taking place on growth in solution, especially in biomineralization processes. Established understanding of the growth of thin films and nanostructures is based around processes involving individual atoms or molecules. According to the author’s research over the last two decades, however, the generation of charged gas phase nuclei is shown to be the rule rather than the exception in the CVD process, and charged gas phase nuclei are actively ...

  2. Polymer Adsorption on Graphite and CVD Graphene Surfaces Studied by Surface-Specific Vibrational Spectroscopy.

    Science.gov (United States)

    Su, Yudan; Han, Hui-Ling; Cai, Qun; Wu, Qiong; Xie, Mingxiu; Chen, Daoyong; Geng, Baisong; Zhang, Yuanbo; Wang, Feng; Shen, Y R; Tian, Chuanshan

    2015-10-14

    Sum-frequency vibrational spectroscopy was employed to probe polymer contaminants on chemical vapor deposition (CVD) graphene and to study alkane and polyethylene (PE) adsorption on graphite. In comparing the spectra from the two surfaces, it was found that the contaminants on CVD graphene must be long-chain alkane or PE-like molecules. PE adsorption from solution on the honeycomb surface results in a self-assembled ordered monolayer with the C-C skeleton plane perpendicular to the surface and an adsorption free energy of ∼42 kJ/mol for PE(H(CH2CH2)nH) with n ≈ 60. Such large adsorption energy is responsible for the easy contamination of CVD graphene by impurity in the polymer during standard transfer processes. Contamination can be minimized with the use of purified polymers free of PE-like impurities.

  3. Cold Vacuum Dryer (CVD) Facility Fire Protection System Design Description (SYS 24)

    Energy Technology Data Exchange (ETDEWEB)

    SINGH, G.

    2000-10-17

    This system design description (SDD) addresses the Cold Vacuum Drying (CVD) Facility fire protection system (FPS). The primary features of the FPS for the CVD are a fire alarm and detection system, automatic sprinklers, and fire hydrants. The FPS also includes fire extinguishers located throughout the facility and fire hydrants to assist in manual firefighting efforts. In addition, a fire barrier separates the operations support (administrative) area from the process bays and process bay support areas. Administrative controls to limit combustible materials have been established and are a part of the overall fire protection program. The FPS is augmented by assistance from the Hanford Fire Department (HED) and by interface systems including service water, electrical power, drains, instrumentation and controls. This SDD, when used in conjunction with the other elements of the definitive design package, provides a complete picture of the FPS for the CVD Facility.

  4. Development of CVD Diamond for Industrial Applications Final Report CRADA No. TC-2047-02

    Energy Technology Data Exchange (ETDEWEB)

    Caplan, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Olstad, R. [General Atomics, San Diego, CA (United States); Jory, H. [Communications and Power Industries, Palo Alto, CA (United States); Vikharov, A. L. [Russian Academy of Sciences (RAS), Moscow (Russian Federation)

    2017-09-08

    This project was a collaborative effort to develop and demonstrate a new millimeter microwave assisted chemical vapor deposition(CVD) process for manufacturing large diamond disks with greatly reduced processing times and costs from those now available. In the CVD process, carbon based gases (methane) and hydrogen are dissociated into plasma using microwave discharge and then deposited layer by layer as polycrystalline diamond onto a substrate. The available low frequency (2.45GHz) microwave sources used elsewhere (De Beers) result in low density plasmas and low deposition rates: 4 inch diamond disks take 6-8 weeks to process. The new system developed in this project uses a high frequency 30GHz Gyrotron as the microwave source and a quasi-optical CVD chamber resulting in a much higher density plasma which greatly reduced the diamond processing times (1-2 weeks)

  5. CVD diamond based soft X-ray detector with fast response

    International Nuclear Information System (INIS)

    Li Fang; Hou Lifei; Su Chunxiao; Yang Guohong; Liu Shenye

    2010-01-01

    A soft X-ray detector has been made with high quality chemical vapor deposited (CVD) diamond and the electrical structure of micro-strip. Through the measurement of response time on a laser with the pulse width of 10 ps, the full width at half maximum of the data got in the oscilloscope was 115 ps. The rise time of the CVD diamond detector was calculated to be 49 ps. In the experiment on the laser prototype facility, the signal got by the CVD diamond detector was compared with that got by a soft X-ray spectrometer. Both signals coincided well. The detector is proved to be a kind of reliable soft X-ray detector with fast response and high signal-to-noise ratio. (authors)

  6. Oxidation protection of multilayer CVD SiC/B/SiC coatings for 3D C/SiC composite

    International Nuclear Information System (INIS)

    Liu Yongsheng; Cheng Laifei; Zhang Litong; Wu Shoujun; Li Duo; Xu Yongdong

    2007-01-01

    A CVD boron coating was introduced between two CVD SiC coating layers. EDS and XRD results showed that the CVD B coating was a boron crystal without other impurity elements. SEM results indicated that the CVD B coating was a flake-like or column-like crystal with a compact cross-section. The crack width in the CVD SiC coating deposited on CVD B is smaller than that in a CVD SiC coating deposited on CVD SiC coating. After oxidation at 700 deg. C and 1000 deg. C, XRD results indicated that the coating was covered by product B 2 O 3 or B 2 O 3 .xSiO 2 film. The cracks were sealed as observed by SEM. There was a large amount of flake-like material on hybrid coating surface after oxidation at 1300 deg. C. Oxidation weight loss and residual flexural strength results showed that hybrid SiC/B/SiC multilayer coating provided better oxidation protection for C/SiC composite than a three layer CVD SiC coating at temperatures from 700 deg. C to 1000 deg. C for 600 min, but worse oxidation protection above 1000 deg. C due to the large amount of volatilization of B 2 O 3 or B 2 O 3 .xSiO 2

  7. Influence of surface morphology and microstructure on performance of CVD tungsten coating under fusion transient thermal loads

    Energy Technology Data Exchange (ETDEWEB)

    Lian, Youyun, E-mail: lianyy@swip.ac.cn [Southwestern Institute of Physics, Chengdu (China); Liu, Xiang; Wang, Jianbao; Feng, Fan [Southwestern Institute of Physics, Chengdu (China); Lv, Yanwei; Song, Jiupeng [China National R& D Center for Tungsten Technology, Xiamen Tungsten Co. Ltd, 361026 Xiamen (China); Chen, Jiming [Southwestern Institute of Physics, Chengdu (China)

    2016-12-30

    Highlights: • Thick CVD-W coatingswere deposited at a rapid growth rate. • The polished CVD-W coatings have highly textured structure and exhibited a very strong preferred orientation. • The polished CVD tungsten coatings show superior thermal shock resistance as compared with that of the as-deposited coatings. • The crack formation of the polished CVD-W was almost suppressed at an elevated temperature. - Abstract: Thick tungsten coatings have been deposited by chemical vapor deposition (CVD) at a rapid growth rate. A series of tungsten coatings with different thickness and surface morphology were prepared. The surface morphology, microstructure and preferred orientation of the CVD tungsten coatings were investigated. Thermal shock analyses were performed by using an electron beam facility to study the influence of the surface morphology and the microstructure on the thermal shock resistance of the CVD tungsten coatings. Repetitive (100 pulses) ELMs-like thermal shock loads were applied at various temperatures between room temperature and 600 °C with pulse duration of 1 ms and an absorbed power density of up to 1 GW/m{sup 2}. The results of the tests demonstrated that the specific surface morphology and columnar crystal structure of the CVD tungsten have significant influence on the surface cracking threshold and crack propagation of the materials. The CVD tungsten coatings with a polished surface show superior thermal shock resistance as compared with that of the as-deposited coatings with a rough surface.

  8. Non-fatal suicidal behaviour at the Johannesburg General Hospital ...

    African Journals Online (AJOL)

    African Journal of Psychiatry. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 8, No 3 (2005) >. Log in or Register to get access to full text downloads.

  9. Prevalence, circumstances and consequences of non-fatal road ...

    African Journals Online (AJOL)

    hefere

    injuries as well as improve safety associated with unintentional injuries. Keywords: .... a drink that contains alcohol (such as beer, wine, spirits, etc.)? ..... whether the systematic road safety management systems that they put in place over about.

  10. Non-fatal suicidal behaviour at the Johannesburg General Hospital

    African Journals Online (AJOL)

    Adele

    2004-10-12

    Oct 12, 2004 ... served high rates are increasing on an international scale. Figures from the World ... They include high self-esteem and social “con- nectedness”, especially ..... Rosenberg ML, Smith JC, Davidson LE, et al. The emergence of ...

  11. Association of BMI with risk of CVD mortality and all-cause mortality.

    Science.gov (United States)

    Kee, Chee Cheong; Sumarni, Mohd Ghazali; Lim, Kuang Hock; Selvarajah, Sharmini; Haniff, Jamaiyah; Tee, Guat Hiong Helen; Gurpreet, Kaur; Faudzi, Yusoff Ahmad; Amal, Nasir Mustafa

    2017-05-01

    To determine the relationship between BMI and risk of CVD mortality and all-cause mortality among Malaysian adults. Population-based, retrospective cohort study. Participants were followed up for 5 years from 2006 to 2010. Mortality data were obtained via record linkages with the Malaysian National Registration Department. Multiple Cox regression was applied to compare risk of CVD and all-cause mortality between BMI categories adjusting for age, gender and ethnicity. Models were generated for all participants, all participants the first 2 years of follow-up, healthy participants, healthy never smokers, never smokers, current smokers and former smokers. All fourteen states in Malaysia. Malaysian adults (n 32 839) aged 18 years or above from the third National Health and Morbidity Survey. Total follow-up time was 153 814 person-years with 1035 deaths from all causes and 225 deaths from CVD. Underweight (BMIBMI ≥30·0 kg/m2) was associated with a heightened risk of CVD mortality. Overweight (BMI=25·0-29·9 kg/m2) was inversely associated with risk of all-cause mortality. Underweight was significantly associated with all-cause mortality in all models except for current smokers. Overweight was inversely associated with all-cause mortality in all participants. Although a positive trend was observed between BMI and CVD mortality in all participants, a significant association was observed only for severe obesity (BMI≥35·0 kg/m2). Underweight was associated with increased risk of all-cause mortality and obesity with increased risk of CVD mortality. Therefore, maintaining a normal BMI through leading an active lifestyle and healthy dietary habits should continue to be promoted.

  12. Thermoluminescent properties of CVD diamond: applications to ionising radiation dosimetry; Proprietes thermoluminescentes du diamant CVD: applications a la dosimetrie des rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    Petitfils, A

    2007-09-15

    Remarkable properties of synthetic diamond (human soft tissue equivalence, chemical stability, non-toxicity) make this material suitable for medical application as thermoluminescent dosimeter (TLD). This work highlights the interest of this material as radiotherapy TLD. In the first stage of this work, we looked after thermoluminescent (TL) and dosimetric properties of polycrystalline diamond made by Chemically Vapor Deposited (CVD) synthesis. Dosimetric characteristics are satisfactory as TLD for medical application. Luminescence thermal quenching on diamond has been investigated. This phenomenon leads to a decrease of dosimetric TL peak sensitivity when the heating rate increases. The second part of this work analyses the use of synthetic diamond as TLD in radiotherapy. Dose profiles, depth dose distributions and the cartography of an electron beam obtained with our samples are in very good agreement with results from an ionisation chamber. It is clearly shown that CVD) diamond is of interest to check beams of treatment accelerators. The use of these samples in a control of treatment with Intensity Modulated Radiation Therapy underlines good response of synthetic diamond in high dose gradient areas. These results indicate that CVD diamond is a promising material for radiotherapy dosimetry. (author)

  13. Partner resources and incidence and survival in two major causes of death

    Directory of Open Access Journals (Sweden)

    Jenny Torssander

    2018-04-01

    Full Text Available Because people tend to marry social equals – and possibly also because partners affect each other’s health – the social position of one partner is associated with the other partner’s health and mortality. Although this link is fairly well established, the underlying mechanisms are not fully identified. Analyzing disease incidence and survival separately may help us to assess when in the course of the disease a partner’s resources are of most significance. This article addresses the importance of partner’s education, income, employment status, and health for incidence and survival in two major causes of death: cancer and cardiovascular diseases (CVD. Based on a sample of Finnish middle-aged and older couples (around 200,000 individuals we show that a partner’s education is more often connected to incidence than to survival, in particular for CVD. Once ill, any direct effect of partner’s education seems to decline: The survival chances after being hospitalized for cancer or CVD are rather associated with partner’s employment status and/or income level when other individual and partner factors are adjusted for. In addition, a partner’s history of poor health predicted higher CVD incidence and, for women, lower cancer survival. The findings suggest that various partner’s characteristics may have different implications for disease and survival, respectively. A wider focus on social determinants of health at the household level, including partner’s social resources, is needed. Keywords: Marital/cohabiting partners, Education, Income, CVD, Cancer, Survival, Finland

  14. Hard coatings by plasma CVD on polycarbonate for automotive and optical applications

    International Nuclear Information System (INIS)

    Schmauder, T.; Nauenburg, K.-D.; Kruse, K.; Ickes, G.

    2006-01-01

    In many applications, plastic surfaces need coatings as a protection against abrasion or weathering. Leybold Optics is developing Plasma CVD processes and machinery for transparent hard coatings (THC) for polycarbonate parts. In this paper we present the current features and remaining challenges of this technique. The coatings generally show excellent adhesion. Abrasion resistance is superior to commonly used lacquers. Climate durability of the coating has been improved to pass the tests demanded by automotive specifications. Current activities are focused on improving the durability under exposure to UV radiation. Estimations show that our high-rate plasma CVD hard coating process is also economically competitive to lacquering

  15. Anisotropy and dimensional characteristics in CVD route Y1Ba2Cu3O7-δ

    International Nuclear Information System (INIS)

    Watanabe, K.; Kobayashi, N.; Awaji, S.; Yamane, H.; Hirai, T.; Muto, Y.

    1993-01-01

    The anisotropic behaviors of the upper critical field B c2 and the critical current density J c were investigated in Y 1 Ba 2 Cu 3 O 7-δ films prepared by a chemical vapor deposition (CVD) route. The angular dependence of J c at fixed temperature, the field dependence of J c at fixed angle, and the temperature dependence of J c at fixed field were measured. The obtained results were explored in terms of the dimensional superconducting characteristics. The important information on the anisotropic behaviors of J c in CVD-Y 1 Ba 2 Cu 3 O 7-δ was discussed from a viewpoint of the flux pinning. (orig.)

  16. Consumption of Yogurt and the Incident Risk of Cardiovascular Disease: A Meta-Analysis of Nine Cohort Studies.

    Science.gov (United States)

    Wu, Lei; Sun, Dali

    2017-03-22

    Previous systematic reviews and meta-analyses have evaluated the association of dairy consumption and the risk of cardiovascular disease (CVD). However, the findings were inconsistent. No quantitative analysis has specifically assessed the effect of yogurt intake on the incident risk of CVD. We searched the PubMed and the Embase databases from inception to 10 January 2017. A generic inverse-variance method was used to pool the fully-adjusted relative risks (RRs) and the corresponding 95% confidence intervals (CIs) with a random-effects model. A generalized least squares trend estimation model was used to calculate the specific slopes in the dose-response analysis. The present systematic review and meta-analysis identified nine prospective cohort articles involving a total of 291,236 participants. Compared with the lowest category, highest category of yogurt consumption was not significantly related with the incident risk of CVD, and the RR (95% CI) was 1.01 (0.95, 1.08) with an evidence of significant heterogeneity (I² = 52%). However, intake of ≥200 g/day yogurt was significantly associated with a lower risk of CVD in the subgroup analysis. There was a trend that a higher level of yogurt consumption was associated with a lower incident risk of CVD in the dose-response analysis. A daily dose of ≥200 g yogurt intake might be associated with a lower incident risk of CVD. Further cohort studies and randomized controlled trials are still demanded to establish and confirm the observed association in populations with different characteristics.

  17. [The estimated incidence and case fatality rate of ischemic and hemorrhagic cerebrovascular disease in 2002 in Catalonia].

    Science.gov (United States)

    Marrugat, Jaume; Arboix, Adrià; García-Eroles, Lluís; Salas, Teresa; Vila, Joan; Castell, Conxa; Tresserras, Ricard; Elosua, Roberto

    2007-06-01

    The aim of this study was to obtain an estimate of the incidence of cerebrovascular disease (CVD) in the Spanish population in 2002. The study involved data on patients aged over 24 years for the year 2002 contained in both the death register and the Minimum Basic Data Set from 65 of the 84 Catalan general hospitals (i.e., 90.7% of all acute hospital beds in Catalonia). Total and age-adjusted mortality rates, cumulative incidence, and hospitalization rates, and the 28-day case fatality rate for CVD in the Catalan population were calculated after cases of traumatic and transient disease had been excluded. The unadjusted CVD mortality rate per 100,000 population aged over 24 years in Catalonia was 92 in men and 119 in women. The age-adjusted rates were 58 (95% confidence interval or CI, 56-61) and 43 (95% CI, 41-44), respectively. The cumulative incidence of CVD per 100,000 population was 218 (95% CI, 214-221) in men and 127 (95% CI, 125-128) in women. The unadjusted 28-day case fatality rate in the population was 36.2%: 30.3% in men and 42.0% in women. Some 62.5% of patients (57.2% of men and 66.4% of women) died from CVD outside hospital. These findings indicate that CVD mortality and incidence rates in Catalonia are among the lowest in developed countries. More than half of the deaths that took place within 28 days after the onset of symptoms occurred outside hospital.

  18. Validation of a model to investigate the effects of modifying cardiovascular disease (CVD) risk factors on the burden of CVD: the rotterdam ischemic heart disease and stroke computer simulation (RISC) model

    NARCIS (Netherlands)

    van Kempen, Bob J. H.; Ferket, Bart S.; Hofman, Albert; Steyerberg, Ewout W.; Colkesen, Ersen B.; Boekholdt, S. Matthijs; Wareham, Nicholas J.; Khaw, Kay-Tee; Hunink, M. G. Myriam

    2012-01-01

    Background: We developed a Monte Carlo Markov model designed to investigate the effects of modifying cardiovascular disease (CVD) risk factors on the burden of CVD. Internal, predictive, and external validity of the model have not yet been established. Methods: The Rotterdam Ischemic Heart Disease

  19. Validation of a model to investigate the effects of modifying cardiovascular disease (CVD) risk factors on the burden of CVD: The rotterdam ischemic heart disease and stroke computer simulation (RISC) model

    NARCIS (Netherlands)

    B.J.H. van Kempen (Bob); B.S. Ferket (Bart); A. Hofman (Albert); E.W. Steyerberg (Ewout); E.B. Colkesen (Ersen); S.M. Boekholdt (Matthijs); N.J. Wareham (Nick); K-T. Khaw (Kay-Tee); M.G.M. Hunink (Myriam)

    2012-01-01

    textabstractBackground: We developed a Monte Carlo Markov model designed to investigate the effects of modifying cardiovascular disease (CVD) risk factors on the burden of CVD. Internal, predictive, and external validity of the model have not yet been established.Methods: The Rotterdam Ischemic

  20. Stereotactic body radiotherapy for medically inoperable patients with stage I non-small cell lung cancer - A first report of toxicity related to COPD/CVD in a non-randomized prospective phase II study

    International Nuclear Information System (INIS)

    Baumann, Pia; Nyman, Jan; Hoyer, Morten; Gagliardi, Giovanna; Lax, Ingmar; Wennberg, Berit; Drugge, Ninni; Ekberg, Lars; Friesland, Signe; Johansson, Karl-Axel; Lund, Jo-Asmund; Morhed, Elisabeth; Nilsson, Kristina; Levin, Nina; Paludan, Merete; Sederholm, Christer; Traberg, Anders; Wittgren, Lena; Lewensohn, Rolf

    2008-01-01

    Background and Aims: In a retrospective study using stereotactic body radiotherapy (SBRT) in medically inoperable patients with stage I NSCLC we previously reported a local control rate of 88% utilizing a median dose of 15 Gy x 3. This report records the toxicity encountered in a prospective phase II trial, and its relation to coexisting chronic obstructive pulmonary disease (COPD) and cardio vascular disease (CVD). Material and methods: Sixty patients were entered in the study between August 2003 and September 2005. Fifty-seven patients (T1 65%, T2 35%) with a median age of 75 years (59-87 years) were evaluable. The baseline mean FEV1% was 64% and median Karnofsky index was 80. A total dose of 45 Gy was delivered in three fractions at the 67% isodose of the PTV. Clinical, pulmonary and radiological evaluations were made at 6 weeks, 3, 6, 9, 12, 18, and 36 months post-SBRT. Toxicity was graded according to CTC v2.0 and performance status was graded according to the Karnofsky scale. Results: At a median follow-up of 23 months, 2 patients had relapsed locally. No grade 4 or 5 toxicity was reported. Grade 3 toxicity was seen in 12 patients (21%). There was no significant decline of FEV1% during follow-up. Low grade pneumonitis developed to the same extent in the CVD 3/17 (18%) and COPD 7/40 (18%) groups. The incidence of fibrosis was 9/17 (53%) and pleural effusions was 8/17 (47%) in the CVD group compared with 13/40 (33%) and 5/40 (13%) in the COPD group. Conclusion: SBRT for stage I NSCLC patients who are medically inoperable because of COPD and CVD results in a favourable local control rate with a low incidence of grade 3 and no grade 4 or 5 toxicity

  1. Thermodynamic and experimental studies of the CVD of A-15 superconductors. I

    International Nuclear Information System (INIS)

    Madar, R.; Weiss, F.; Fruchart, R.; Bernard, C.

    1978-01-01

    This paper deals with the experimental and thermodynamic study of the chemical vapor deposition (CVD) synthesis of Nb 3 Ga layers on various metallic and insulating substrates using the coreduction of mixed halides by hydrogen. Thermodynamic equilibrium in the seven-component system Nb-Ga-H-Cl-Si-O-Ar has been calculated using the method of minimization of the system Gibbs free energy as a function of the variables directly available in the CVD system. The chosen variables were the chloride ratio, the reduction and dilution parameters and the temperature of the deposition zone. The equilibrium compositions were calculated for the two composition limits of the A-15 phase: NbGasub(0.15) and Nb 3 Ga. They are presented in the form of CVD phase diagrams. A CVD reactor has been set up and more than one hundred measurements have been made in order to check the validity of the equilibrium calculations. The comparisons between equilibrium and experimental results show a good agreement and lead to a better understanding of the chemistry and thermodynamics of the system. (Auth.)

  2. Control of Reaction Surface in Low Temperature CVD to Enhance Nucleation and Conformal Coverage

    Science.gov (United States)

    Kumar, Navneet

    2009-01-01

    The Holy Grail in CVD community is to find precursors that can afford the following: good nucleation on a desired substrate and conformal deposition in high AR features. Good nucleation is not only necessary for getting ultra-thin films at low thicknesses; it also offers films that are smooth at higher thickness values. On the other hand,…

  3. CVD of SiC and AlN using cyclic organometallic precursors

    Science.gov (United States)

    Interrante, L. V.; Larkin, D. J.; Amato, C.

    1992-01-01

    The use of cyclic organometallic molecules as single-source MOCVD precursors is illustrated by means of examples taken from our recent work on AlN and SiC deposition, with particular focus on SiC. Molecules containing (AlN)3 and (SiC)2 rings as the 'core structure' were employed as the source materials for these studies. The organoaluminum amide, (Me2AlNH2)3, was used as the AlN source and has been studied in a molecular beam sampling apparatus in order to determine the gas phase species present in a hot-wall CVD reactor environment. In the case of SiC CVD, a series of disilacyclobutanes (Si(XX')CH2)2 (with X and X' = H, CH3, and CH2SiH2CH3), were examined in a cold-wall, hot-stage CVD reactor in order to compare their relative reactivities and prospective utility as single-source CVD precursors. The parent compound, disilacyclobutane, (SiH2CH2)2, was found to exhibit the lowest deposition temperature (ca. 670 C) and to yield the highest purity SiC films. This precursor gave a highly textured, polycrystalline film on the Si(100) substrates.

  4. CVD growth and characterization of 3C-SiC thin films

    Indian Academy of Sciences (India)

    Unknown

    Cubic silicon carbide (3C-SiC) thin films were grown on (100) and (111) Si substrates by CVD technique using ... of grown films were studied using optical microscopy, scanning electron microscopy (SEM), X-ray diffraction (XRD) analysis and X-ray ... the oxide mask gets damaged (Edgar et al 1998). There- fore, lower ...

  5. The effect of percentage carbonon the CVD coating of plain carbon ...

    African Journals Online (AJOL)

    Two steels En 3 and En 39 were given a TiC-TiN CVD coating in the carburized and uncarburized conditions. The continuity of the coatings and their adherance to the substrate were examined. The thickness of the deposited coatings were also measured, their adherence to the substrate and their thickness was off ected by ...

  6. Hexagonal Boron Nitride assisted transfer and encapsulation of large area CVD graphene

    Science.gov (United States)

    Shautsova, Viktoryia; Gilbertson, Adam M.; Black, Nicola C. G.; Maier, Stefan A.; Cohen, Lesley F.

    2016-07-01

    We report a CVD hexagonal boron nitride (hBN-) assisted transfer method that enables a polymer-impurity free transfer process and subsequent top encapsulation of large-area CVD-grown graphene. We demonstrate that the CVD hBN layer that is utilized in this transfer technique acts as a buffer layer between the graphene film and supporting polymer layer. We show that the resulting graphene layers possess lower doping concentration, and improved carrier mobilities compared to graphene films produced by conventional transfer methods onto untreated SiO2/Si, SAM-modified and hBN covered SiO2/Si substrates. Moreover, we show that the top hBN layer used in the transfer process acts as an effective top encapsulation resulting in improved stability to ambient exposure. The transfer method is applicable to other CVD-grown 2D materials on copper foils, thereby facilitating the preparation of van der Waals heterostructures with controlled doping.

  7. The integration of epigenetics and genetics in nutrition research for CVD risk factors

    Science.gov (United States)

    There is increasing evidence documenting gene-by-environment (G x E) interactions for CVD related traits. However, the underlying mechanisms are still unclear. DNA methylation may represent one of such potential mechanisms. The objective of this review paper is to summarise the current evidence supp...

  8. CVD of solid oxides in porous substrates for ceramic membrane modification

    NARCIS (Netherlands)

    Lin, Y.S.; Lin, Y.S.; Burggraaf, Anthonie; Burggraaf, A.J.

    1992-01-01

    The deposition of yttria-doped zirconia has been experimented systematically in various types of porous ceramic substrates by a modified chemical vapor deposition (CVD) process operating in an opposing reactant geometry using water vapor and corresponding metal chloride vapors as reactants. The

  9. Large-area selective CVD epitaxial growth of Ge on Si substrates

    NARCIS (Netherlands)

    Sammak, A.; De Boer, W.; Nanver, L.K.

    2011-01-01

    Selective epitaxial growth of crystalline Ge on Si in a standard ASM Epsilon 2000 CVD reactor is investigated for the fabrication of Ge p+n diodes. At the deposition temperature of 700?C, most of the lattice mismatch-defects are trapped within first 300nm of Ge growth and good quality single crystal

  10. Merging Standard CVD Techniques for GaAs and Si Epitaxial Growth

    NARCIS (Netherlands)

    Sammak, A.; De Boer, W.; Van den Bogaard, A.; Nanver, L.K.

    2010-01-01

    A commercial Chemical Vapor Deposition (CVD) system, the ASMI Epsilon 2000 designed for Si and SiGe epitaxy, has, for the first time, been equipped for the growth of GaAs compounds in a manner that does not exclude the use of the system also for Si-based depositions. With the new system, intrinsic,

  11. Ge-on-Si : Single-Crystal Selective Epitaxial Growth in a CVD Reactor

    NARCIS (Netherlands)

    Sammak, A.; De Boer, W.B.; Nanver, L.K.

    2012-01-01

    A standard Si/SiGe ASM CVD reactor that was recently modified for merging GaAs and Si epitaxial growth in one system is utilized to achieve intrinsic and doped epitaxial Ge-on-Si with low threading dislocation and defect densities. For this purpose, the system is equipped with 2% diluted GeH4 as the

  12. Synthesis of crystalline Ge nanoclusters in PE-CVD-deposited SiO2 films

    DEFF Research Database (Denmark)

    Leervad Pedersen, T.P.; Skov Jensen, J.; Chevallier, J.

    2005-01-01

    The synthesis of evenly distributed Ge nanoclusters in plasma-enhanced chemical-vapour-deposited (PE-CVD) SiO2 thin films containing 8 at. % Ge is reported. This is of importance for the application of nanoclusters in semiconductor technology. The average diameter of the Ge nanoclusters can...

  13. Hydrogen termination of CVD diamond films by high-temperature annealing at atmospheric pressure

    NARCIS (Netherlands)

    Seshan, V.; Ullien, D.; Castellanos-Gomez, A.; Sachdeva, S.; Murthy, D.H.K.; Savenije, T.J.; Ahmad, H.A.; Nunney, T.S.; Janssens, S.D.; Haenen, K.; Nesládek, M.; Van der Zant, H.S.J.; Sudhölter, E.J.R.; De Smet, L.C.P.M.

    2013-01-01

    A high-temperature procedure to hydrogenate diamond films using molecular hydrogen at atmospheric pressure was explored. Undoped and doped chemical vapour deposited (CVD) polycrystalline diamond films were treated according to our annealing method using a H2 gas flow down to ?50 ml/min (STP) at

  14. An economic CVD technique for pure SnO 2 thin films deposition

    Indian Academy of Sciences (India)

    A modified new method of CVD for formation of pure layers of tin oxide films was developed. This method is very simple and inexpensive and produces films with good electrical properties. The effect of substrate temperature on the sheet resistance, resistivity, mobility, carrier concentration and transparency of the films has ...

  15. A beam radiation monitor based on CVD diamonds for SuperB

    Science.gov (United States)

    Cardarelli, R.; Di Ciaccio, A.

    2013-08-01

    Chemical Vapor Deposition (CVD) diamond particle detectors are in use in the CERN experiments at LHC and at particle accelerator laboratories in Europe, USA and Japan mainly as beam monitors. Nowadays it is considered a proven technology with a very fast signal read-out and a very high radiation tolerance suitable for measurements in high radiation environment zones i.e. near the accelerators beam pipes. The specific properties of CVD diamonds make them a prime candidate for measuring single particles as well as high-intensity particle cascades, for timing measurements on the sub-nanosecond scale and for beam protection systems in hostile environments. A single-crystalline CVD (scCVD) diamond sensor, read out with a new generation of fast and high transition frequency SiGe bipolar transistor amplifiers, has been tested for an application as radiation monitor to safeguard the silicon vertex tracker in the SuperB detector from excessive radiation damage, cumulative dose and instantaneous dose rates. Test results with 5.5 MeV alpha particles from a 241Am radioactive source and from electrons from a 90Sr radioactive source are presented in this paper.

  16. Photo-Hall measurements on phosphorus-doped n-type CVD diamond at low temperatures

    Czech Academy of Sciences Publication Activity Database

    Remeš, Zdeněk; Kalish, R.; Uzan-Saguy, C.; Baskin, E.; Nesládek, M.; Koizumi, S.

    2003-01-01

    Roč. 199, č. 1 (2003), s. 82-86 ISSN 0031-8965 EU Projects: European Commission(XE) HPRN-CT-1999-00139 Institutional research plan: CEZ:AV0Z1010914 Keywords : photo-Hall measurements * CVD diamonnd * phosphorus doped Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.950, year: 2003

  17. An economic CVD technique for pure SnO2 thin films deposition ...

    Indian Academy of Sciences (India)

    An economic CVD technique for pure SnO2 thin films deposition: Temperature effects ..... C are depicted in figure 7. It is observed that the cut-off wave- ... cating that the energy gap of the SnO2 films varies among. 3·54, 3·35 and 1·8 eV.

  18. Thermoluminescence properties of undoped diamond films deposited using HF CVD technique

    Directory of Open Access Journals (Sweden)

    Paprocki K.

    2018-03-01

    Full Text Available Natural diamond has been considered as a perspective material for clinical radiation dosimetry due to its tissuebiocompatibility and chemical inertness. However, the use of natural diamond in radiation dosimetry has been halted by the high market price. The recent progress in the development of CVD techniques for diamond synthesis, offering the capability of growing high quality diamond layers, has renewed the interest in using this material in radiation dosimeters having small geometricalsizes. Polycrystalline CVD diamond films have been proposed as detectors and dosimeters of β and α radiation with prospective applications in high-energy photon dosimetry. In this work, we present a study on the TL properties of undoped diamond film samples grown by the hot filament CVD (HF CVD method and exposed to β and α radiation. The glow curves for both types of radiation show similar character and can be decomposed into three components. The dominant TL peaks are centered at around 610 K and exhibit activation energy of the order of 0.90 eV.

  19. Superconductivity and low temperature electrical transport in B-doped CVD nanocrystalline diamond

    Czech Academy of Sciences Publication Activity Database

    Nesládek, M.; Mareš, Jiří J.; Tromson, D.; Mer, Ch.; Bergonzo, P.; Hubík, Pavel; Krištofik, Jozef

    2006-01-01

    Roč. 7, Suppl. 1 (2006), S41-S44 ISSN 1468-6996 R&D Projects: GA ČR(CZ) GA202/06/0040 Institutional research plan: CEZ:AV0Z10100521 Keywords : superconductivity * electrical transport * doping * CVD diamond Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.124, year: 2006

  20. Thermoluminescence properties of undoped and nitrogen-doped CVD diamond exposed to gamma radiation

    International Nuclear Information System (INIS)

    Barboza-Flores, M.; Gastelum, S.; Cruz-Zaragoza, E.; Melendrez, R.; Chernov, V.; Pedroza-Montero, M.; Favalli, A.

    2008-01-01

    It is known that the thermoluminescence (TL) performance of CVD diamond depends on the impurity concentration and doping materials introduced during growing. We report on the TL properties of undoped and 750 ppm nitrogen-doped CVD diamond grown on (0 0 1) silicon substrate. The samples were exposed to gamma radiation from a Gammacell 200 Nordion irradiator in the 10-500 Gy dose range at 627 mGy/min dose rate. The nitrogen-doped CVD diamond sample exhibited a TL glow curve peaked around 537 K and a small shoulder about 411 K and a linear dose behavior in the 10-60 Gy dose range. In contrast, the undoped specimen showed a 591 K peaked TL glow curve and linear dose response for 10-100 Gy doses. However, both samples displayed a non-linear dose response for doses higher than 100 Gy. The doping effects seem to cause a higher TL efficiency, which may be attributed to the differences in the diamond bonding and amorphous carbon on the CVD samples as well as to the presence of nitrogen. In addition, the nitrogen content may produce some structural and morphological surface effects, which may account for the distinctive TL features and dose response of the diamond samples

  1. Red blood cell rheology in patients with chronic venous disease (CVD)

    NARCIS (Netherlands)

    Chwała, Maciej; Spannbauer, Anna; Teległów, Aneta; Cencora, Andrzej; Marchewka, Anna; Hardeman, Max R.; Dabrowski, Zbigniew

    2009-01-01

    Rheological studies concerning aggregation and elongation of erythrocytes were carried out in 21 patients (mean age 56 years) with chronic venous disease (CVD) and 10 (mean age 45 years) healthy control subjects, with the use of a LORCA device. Higher values of parameters characterizing both

  2. Optimization of CVD parameters for long ZnO NWs grown on ITO

    Indian Academy of Sciences (India)

    The optimization of chemical vapour deposition (CVD) parameters for long and vertically aligned (VA) ZnO nanowires (NWs) were investigated. Typical ZnO NWs as a single crystal grown on indium tin oxide (ITO)-coated glass substrate were successfully synthesized. First, the conducted side of ITO–glass substrate was ...

  3. Computation of flow and thermal fields in a model CVD reactor

    Indian Academy of Sciences (India)

    Mixing of coaxial jets within a tube in the presence of blockage has been numerically studied. This configuration is encountered during the modelling of flow and heat transfer in CVD (chemical vapour deposition) reactors. For the conditions prevailing in the reactor, the Reynolds numbers are low and flow can be taken to be ...

  4. The role of (sub)-surface oxygen on the surface electronic structure of hydrogen terminated (100) CVD diamond

    NARCIS (Netherlands)

    Deferme, W.; Tanasa, G.; Amir, J.; Haenen, K.; Nesladek, M.; Flipse, C.F.J.

    2006-01-01

    In this work, scanning tunnelling microscopy (STM) and scanning tunnelling spectroscopy (STS) were applied to investigate the surface morphol. and the surface electronic structure of plasma-treated (100)-oriented CVD diamond films. These films were hydrogenated using a conventional MWPE-CVD

  5. Cold-walled UHV/CVD batch reactor for the growth of Si1_x/Gex layers

    DEFF Research Database (Denmark)

    Thomsen, Erik Vilain; Christensen, Carsten; Andersen, C.R.

    1997-01-01

    A novel cold-walled, lamp-heated, ultrahigh vacuum chemical vapor deposition (UHV/CVD) batch system for the growth of SiGe layers is presented. This system combines the batch capability of the standard UHV/CVD furnace with the temperature processing available in rapid thermal processing (Rm...

  6. Dietary sodium to potassium ratio and the incidence of hypertension and cardiovascular disease: A population-based longitudinal study.

    Science.gov (United States)

    Mirmiran, Parvin; Bahadoran, Zahra; Nazeri, Pantea; Azizi, Fereidoun

    2018-01-30

    There is an interaction between dietary sodium/potassium intake in the pathogenesis of hypertension (HTN) and cardiovascular disease (CVD). The aim of this study was to investigate the association of dietary sodium to potassium (Na/K) ratio and the risk of HTN and CVD in a general population of Iranian adults. In this prospective cohort study, adults men and women with complete baseline data were selected from among participants of the Tehran Lipid and Glucose Study and were followed up for 6.3 years for incidence of HTN and CVD outcomes. Dietary sodium and potassium were assessed using a valid and reliable 168-item food frequency questionnaire. Cox proportional hazards regression models were used to estimate hazard ratios (HRs) and 95% confidence intervals (CIs) for the association between dietary sodium, potassium and their ratio and risk of outcomes. During the study follow-up, 291 (15.1%) and 79 (5.0%) new cases of HTN and CVD were identified, respectively. No significant association was observed between usual intakes of sodium, potassium and dietary Na/K ratio with the incidence of HTN. There was no significant association between dietary intakes of sodium and potassium per se and the risk of CVD, whereas when dietary sodium to potassium ratio was considered as exposure in the fully-adjusted Cox regression model, and participants in the highest compared to lowest tertile had a significantly increased risk of CVD (HR = 2.19, 95% CI = 1.16-4.14). Our findings suggest that high dietary Na/K ratio could contribute to increased risk of CVD events.

  7. Mediterranean Diet and 10-year (2002-2012) Incidence of Diabetes and Cardiovascular Disease in Participants with Prediabetes: The ATTICA study

    Science.gov (United States)

    Filippatos, Theodosios D.; Panagiotakos, Demosthenes B.; Georgousopoulou, Ekavi N.; Pitaraki, Evangelia; Kouli, Georgia-Maria; Chrysohoou, Christina; Tousoulis, Dimitrios; Stefanadis, Christodoulos; Pitsavos, Christos; the ATTICA Study Group

    2016-01-01

    BACKGROUND: Prediabetes has been related to an increased risk of developing diabetes and cardiovascular disease (CVD). AIM: The aim of the present study was to examine the effect of the Mediterranean diet on diabetes and CVD risk in subjects with impaired fasting glucose (IFG, i.e. fasting plasma glucose 100-125 mg/dl). METHODS: During 2001-2002, 3042 men and women (>18y) were enrolled for the study. The participants showed no clinical evidence of CVD or any other chronic disease, and were living in the greater Athens (Greece) area. In 2011 and 2012, the 10-year follow-up examinations were performed, including a working sample of n = 1875 participants without diabetes at baseline. Adherence to the Mediterranean diet at baseline evaluation was assessed using the MedDietScore (range 0-55). RESULTS: The prediabetic subjects (n = 343) had a significantly higher incidence of diabetes (25% vs. 10%, p 35/55 score) was associated with lower 10-year incidence of diabetes and CVD. In multiple logistic regression models, participants with high levels of adherence to the Mediterranean diet were significantly less affected by diabetes and CVD than those with low adherence levels. CONCLUSION: High adherence to the Mediterranean diet is associated with a low risk of developing diabetes and CVD in prediabetic subjects. PMID:28278309

  8. Correlates of CVD and discussing sexual issues with physicians among male military veterans.

    Science.gov (United States)

    Smith, Matthew Lee; Goltz, Heather Honoré; Motlagh, Audry S; Ahn, SangNam; Bergeron, Caroline D; Ory, Marcia G

    2016-10-01

    This study aims to identify socio-demographic and health behavior factors associated with cardiovascular disease (CVD) diagnosis and patient-physician communication concerning sexual issues among older Veterans. Cross-sectional data were collected from 635 male Veterans over age 55 years as part of the 2010 National Social Life, Health and Aging Project, a nationally-representative, population-based study of community-dwelling older Americans. Two independent logistic regression analyses were performed. Over 33% of Veterans were aged 75 years or older. Over one-half of participants reported having a CVD diagnosis (58%) and sexual intercourse within the previous year (58%); over one-third (37%) reported having one or more sexual dysfunctions and discussing sexual issues with their physician (42%). Veterans diagnosed with CVD were significantly more likely to self-identify as racial/ethnic minorities (OR=1.89, P=0.021), have more chronic disease comorbidities (OR=1.23, P=0.041), and have more sexual dysfunctions (OR=1.19, P=0.028). Veterans diagnosed with CVD were significantly less likely to report having sex within the previous year (OR=0.53, P=0.005). Veterans who reported discussing sexual issues with a physician were significantly more likely to be ≥75 years (OR=1.79, P=0.010), and report more than a high school education (OR=1.62, P=0.016), CVD diagnosis (OR=1.59, P=0.015), sex within the previous year (OR=1.69, P=0.033), and trouble achieving/maintaining an erection (OR=3.39, Paging and sexual health/counseling services. These services should promote increased patient-physician communication as well as referrals between physicians and sex health/counseling specialists. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Superhydrophobic Copper Surfaces with Anticorrosion Properties Fabricated by Solventless CVD Methods.

    Science.gov (United States)

    Vilaró, Ignasi; Yagüe, Jose L; Borrós, Salvador

    2017-01-11

    Due to continuous miniaturization and increasing number of electrical components in electronics, copper interconnections have become critical for the design of 3D integrated circuits. However, corrosion attack on the copper metal can affect the electronic performance of the material. Superhydrophobic coatings are a commonly used strategy to prevent this undesired effect. In this work, a solventless two-steps process was developed to fabricate superhydrophobic copper surfaces using chemical vapor deposition (CVD) methods. The superhydrophobic state was achieved through the design of a hierarchical structure, combining micro-/nanoscale domains. In the first step, O 2 - and Ar-plasma etchings were performed on the copper substrate to generate microroughness. Afterward, a conformal copolymer, 1H,1H,2H,2H-perfluorodecyl acrylate-ethylene glycol diacrylate [p(PFDA-co-EGDA)], was deposited on top of the metal via initiated CVD (iCVD) to lower the surface energy of the surface. The copolymer topography exhibited a very characteristic and unique nanoworm-like structure. The combination of the nanofeatures of the polymer with the microroughness of the copper led to achievement of the superhydrophobic state. AFM, SEM, and XPS were used to characterize the evolution in topography and chemical composition during the CVD processes. The modified copper showed water contact angles as high as 163° and hysteresis as low as 1°. The coating withstood exposure to aggressive media for extended periods of time. Tafel analysis was used to compare the corrosion rates between bare and modified copper. Results indicated that iCVD-coated copper corrodes 3 orders of magnitude slower than untreated copper. The surface modification process yielded repeatable and robust superhydrophobic coatings with remarkable anticorrosion properties.

  10. Circulating N-Linked Glycoprotein Side-Chain Biomarker, Rosuvastatin Therapy, and Incident Cardiovascular Disease: An Analysis From the JUPITER Trial.

    Science.gov (United States)

    Akinkuolie, Akintunde O; Glynn, Robert J; Padmanabhan, Latha; Ridker, Paul M; Mora, Samia

    2016-07-13

    GlycA, a novel protein glycan biomarker of N-acetyl side chains of acute-phase proteins, was recently associated with incident cardiovascular disease (CVD) in healthy women. Whether GlycA predicts CVD events in the setting of statin therapy in men and women without CVD but with evidence of chronic inflammation is unknown. In the Justfication for the Use of Statins in Prevention: an Intervention Trial Evaluating Rosuvastatin (JUPITER) trial (NCT00239681), participants with low-density lipoprotein cholesterol 0.20). In the JUPITER trial, increased levels of GlycA were associated with an increased risk of CVD events independent of traditional risk factors and hsCRP. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00239681. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  11. Higher plasma soluble Receptor for Advanced Glycation End Products (sRAGE) levels are associated with incident cardiovascular disease and all-cause mortality in type 1 diabetes

    DEFF Research Database (Denmark)

    Nin, Johanna W M; Jorsal, Anders; Ferreira, Isabel

    2010-01-01

    To investigate the associations of plasma levels of soluble receptor for advanced glycation end products (sRAGE) with incident cardiovascular disease (CVD) and all-cause mortality in type 1 diabetes and the extent to which any such associations could be explained by endothelial and renal dysfunct......To investigate the associations of plasma levels of soluble receptor for advanced glycation end products (sRAGE) with incident cardiovascular disease (CVD) and all-cause mortality in type 1 diabetes and the extent to which any such associations could be explained by endothelial and renal...

  12. The incidence and prevalence of diabetes mellitus and related atherosclerotic complications in Korea: a National Health Insurance Database Study.

    Directory of Open Access Journals (Sweden)

    Bo Kyung Koo

    Full Text Available The incidence and prevalence of type 2 diabetes mellitus (T2DM and related macrovascular complications in Korea were estimated using the Health Insurance Review and Assessment (HIRA database from 2007-2011, which covers the claim data of 97.0% of the Korean population.T2DM, coronary artery disease (CAD, cerebrovascular disease (CVD, and peripheral artery disease (PAD were defined according to ICD-10 codes. We used the Healthcare Common Procedure Coding System codes provided by HIRA to identify associated procedures or surgeries. When calculating incidence, we excluded cases with preexisting T2DM within two years before the index year. A Poisson distribution was assumed when calculating 95% confidence intervals for prevalence and incidence rates.The prevalence of T2DM in Korean adults aged 20-89 years was 6.1-6.9% and the annual incidence rates of T2DM ranged from 9.5-9.8/1,000 person-year (PY during the study period. The incidence rates of T2DM in men and women aged 20-49 years showed decreasing patterns from 2009 to 2011 (P<0.001; by contrast, the incidence in subjects aged 70-79 years showed increased patterns from 2009 to 2011 (P<0.001. The incidence rates of CAD and CVD in patients newly diagnosed with T2DM were 18.84/1,000 PY and 11.32/1,000 PY, respectively, in the year of diagnosis. Among newly diagnosed individuals with T2DM who were undergoing treatment for PAD, 14.6% underwent angioplasty for CAD during the same period.Our study measured the national incidences of T2DM, CAD, CVD, and PAD, which are of great concern for public health. We also confirmed the relatively higher risk of CAD and CVD newly detected T2DM patients compared to the general population in Korea.

  13. Incidence of colorectal cancer in new users and non-users of low-dose aspirin without existing cardiovascular disease: A cohort study using The Health Improvement Network.

    Science.gov (United States)

    Cea Soriano, Lucía; Soriano-Gabarró, Montse; García Rodríguez, Luis A

    2017-12-01

    Evidence regarding the chemo-protective effects of aspirin has influenced expert opinion in favour of low-dose aspirin use in certain patient populations without cardiovascular disease (CVD). The effects of aspirin in reducing the incidence of colorectal cancer (CRC) may be a large contributor to this favourable risk-benefit profile of low-dose aspirin in primary CVD prevention. Using The Health Improvement Network, we estimated the incidence of CRC in individuals free of CVD and either prescribed or not prescribed prophylactic low-dose aspirin. Two cohorts - new-users of low-dose aspirin (N=109,426) and a comparator cohort of non-users (N=154,056) at start of follow-up - were followed (maximum 13years) to identify incident CRC cases. Individuals with a record of CVD, cancer or low-dose aspirin prescription before start of follow-up were excluded. 2330 incident cases of CRC occurred; 885 in the aspirin cohort and 1445 in the comparator cohort, after mean follow-ups of 5.43years and 5.17years, respectively. Incidence rates of CRC per 10,000 person-years (95% confidence interval) were 14.90 (13.95-15.92) in the aspirin cohort and 18.15 (17.24-19.12) in the comparator cohort; incidence rate ratio 0.82 (0.76-0.89) adjusted for age, sex and primary care practitioner (PCP) visits in the previous year. Lower incidence rates were seen in the aspirin cohort for all strata evaluated (gender, age group and number of PCP visits in the previous year) except those aged ≥80years. Among most individuals without established CVD, initiation of low-dose aspirin is associated with a reduced incidence of CRC. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. FY1995 development of a clean CVD process by evaluation and control of gas phase nucleation phenomena; 1995 nendo kisokaku seisei gensho no hyoka to seigyo ni yoru clean CVD process no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The purpose of this study is to develop a high-rate and clean chemical vapor deposition (CVD) process as a breakthrough technique to overcome the problems that particles generated in the gas phase during CVD process for preparation of functional thin films cause reduced product yield and deterioration of the films. In the CVD process proposed here, reactant gas and generated particles are electrically charged to control the motion of them with an electric field. In this study, gas-phase nucleation phenomena are evaluated both theoretically and experimentally. A high-rate, ionized CVD method is first developed, in which reactant gas and generated particles are charged with negative ions generated from a radioisotope source and the UV/photoelectron method, and the motion of the charged gas and particles is controlled with an electric field. Charging and transport processes of fine particles are then investigated experimentally and theoretically to develop a clean CVD method in which generated particles are removed with the electric forces. As a result, quantitative evaluation of the charging and transport process was made possible. We also developed devices for measuring the size distribution and concentration of fine particles in low pressure gas such as those found in plasma CVD processes. In addition, numerical simulation and experiments in this study for a TEOS/O{sub 3} CVD process to prepare thin films could determine reaction rates which have not been known so far and give information on selecting good operation conditions for the process. (NEDO)

  15. Triglyceride-to-high-density-lipoprotein-cholesterol ratio is an index of heart disease mortality and of incidence of type 2 diabetes mellitus in men.

    Science.gov (United States)

    Vega, Gloria Lena; Barlow, Carolyn E; Grundy, Scott M; Leonard, David; DeFina, Laura F

    2014-02-01

    High triglyceride (TG) and low high-density lipoprotein cholesterol (HDL-C) impart risk for heart disease. This study examines the relationships of TG/HDL-C ratio to mortality from all causes, coronary heart disease (CHD), or cardiovascular disease (CVD). Survival analysis was done in 39,447 men grouped by TG/HDL-C ratio cut point of 3.5 and for metabolic syndrome. National Death Index International Classification of Diseases (ICD-9 and ICD-10) codes were used for CVD and CHD deaths occurring from 1970 to 2008. Incidence of type 2 diabetes mellitus (DM) according to ratio was estimated in 22,215 men. Triglyceride/HDL-C ratio and cross-product of TG and fasting blood glucose (TyG index) were used in analysis. Men were followed up for 581,194 person-years. Triglyceride/HDL-C ratio predicted CHD, CVD, and all-cause mortality after adjustment for established risk factors and non-HDL-C. Mortality rates were higher in individuals with a high ratio than in those with a low ratio. Fifty-five percent of men had metabolic syndrome that was also predictive of CHD, CVD, and all-cause mortality. Annual incidence of DM was 2 times higher in men with high TG/HDL-C ratio than in those with a low ratio. Individuals with high TG/HDL-C ratio had a higher incidence of DM than those with a low ratio. The TyG index was not equally predictive of causes of mortality to TG/HDL-C, but both were equally predictive of diabetes incidence. Triglyceride/HDL-C ratio predicts CHD and CVD mortality as well as or better than do metabolic syndrome in men. Also, a high ratio predisposes to DM. The TyG index does not predict CHD, CVD, or all-cause mortality equally well, but like TG/HDL-C ratio, it predicts DM incidence.

  16. Hard Coat Layers by PE-CVD Process for the Top Surface of Touch Panel

    International Nuclear Information System (INIS)

    Okunishi, T; Sato, N; Yazawa, K

    2013-01-01

    In order to protect surface from damages, the high pencil hardness and the high abrasion resistance are required for the hard coat layers on polyethylene telephthalate (PET) films for the application of touch panel surface. We have already found that the UV-curing-hard-coat-polymer (UHP) coated PET films show the poor abrasion resistance, while they have the high pencil hardness. It reveals that the abrasion resistance of hard coat layers of the UHP is not simply dependent on the pencil hardness. In this work, we have studied to improve the abrasion resistance of SiOC films as hard coat layers, which were formed by PE-CVD process on UHP coated PET. The abrasion resistance was evaluated by Taber abrasion test. PE-CVD hard coat layers which formed on UHP coater PET films have showed the better abrasion resistance and have the possibility of substitution to the thin glass sheets for touch panel application.

  17. Comparative study of dlc coatings by pvd against cvd technique on textile dents

    International Nuclear Information System (INIS)

    Malik, M.; Alam, S.; Iftikhar, F.

    2007-01-01

    Diamond like Carbon (DLC) film is a hard amorphous carbon hydride film formed by Physical or Chemical vapor deposition (PVD or CVD) techniques. Due to its unique properties especially high hardness, lower coefficient of friction and lubricious nature, these coatings are not only used to extend the life of cutting tools but also for non cutting applications such as for forming dies, molds and on many functional parts of textile. In the present work two techniques were employed i.e. PVD and CVD for deposition of diamond like carbon film on textile dents. These dents are used as thread guider in high speed weaving machine. The measurement of coating thickness, adhesion, hardness and roughness values indicates that overall properties of DLC coating developed by PVD LARC technology reduces abrasion and increases the workability and durability of textile dents as well as suppress the need of lubricants. (author)

  18. Thermodynamic study of CVD-ZrO{sub 2} phase diagrams

    Energy Technology Data Exchange (ETDEWEB)

    Torres-Huerta, A.M., E-mail: atorresh@ipn.m [Research Center for Applied Science and Advanced Technology, Altamira-IPN, Altamira C.P.89600 Tamaulipas (Mexico); Vargas-Garcia, J.R. [Dept of Metallurgical Eng., ESIQIE-IPN, Mexico 07300 D.F. (Mexico); Dominguez-Crespo, M.A. [Research Center for Applied Science and Advanced Technology, Altamira-IPN, Altamira C.P.89600 Tamaulipas (Mexico); Romero-Serrano, J.A. [Dept of Metallurgical Eng., ESIQIE-IPN, Mexico 07300 D.F. (Mexico)

    2009-08-26

    Chemical vapor deposition (CVD) of zirconium oxide (ZrO{sub 2}) from zirconium acetylacetonate Zr(acac){sub 4} has been thermodynamically investigated using the Gibbs' free energy minimization method and the FACTSAGE program. Thermodynamic data Cp{sup o}, DELTAH{sup o} and S{sup o} for Zr(acac){sub 4} have been estimated using the Meghreblian-Crawford-Parr and Benson methods because they are not available in the literature. The effect of deposition parameters, such as temperature and pressure, on the extension of the region where pure ZrO{sub 2} can be deposited was analyzed. The results are presented as calculated CVD stability diagrams. The phase diagrams showed two zones, one of them corresponds to pure monoclinic phase of ZrO{sub 2} and the other one corresponds to a mix of monoclinic phase of ZrO{sub 2} and graphite carbon.

  19. Pulse-height defect in single-crystal CVD diamond detectors

    Energy Technology Data Exchange (ETDEWEB)

    Beliuskina, O.; Imai, N. [The University of Tokyo, Center for Nuclear Study, Wako, Saitama (Japan); Strekalovsky, A.O.; Aleksandrov, A.A.; Aleksandrova, I.A.; Ilich, S.; Kamanin, D.V.; Knyazheva, G.N.; Kuznetsova, E.A.; Mishinsky, G.V.; Pyatkov, Yu.V.; Strekalovsky, O.V.; Zhuchko, V.E. [JINR, Flerov Laboratory of Nuclear Reactions, Dubna, Moscow Region (Russian Federation); Devaraja, H.M. [Manipal University, Manipal Centre for Natural Sciences, Manipal, Karnataka (India); Heinz, C. [II. Physikalisches Institut, Justus-Liebig-Universitaet Giessen, Giessen (Germany); Heinz, S. [II. Physikalisches Institut, Justus-Liebig-Universitaet Giessen, Giessen (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Hofmann, S.; Kis, M.; Kozhuharov, C.; Maurer, J.; Traeger, M. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Pomorski, M. [CEA, LIST, Diamond Sensor Laboratory, CEA/Saclay, Gif-sur-Yvette (France)

    2017-02-15

    The pulse-height versus deposited energy response of a single-crystal chemical vapor deposition (scCVD) diamond detector was measured for ions of Ti, Cu, Nb, Ag, Xe, Au, and of fission fragments of {sup 252} Cf at different energies. For the fission fragments, data were also measured at different electric field strengths of the detector. Heavy ions have a significant pulse-height defect in CVD diamond material, which increases with increasing energy of the ions. It also depends on the electrical field strength applied at the detector. The measured pulse-height defects were explained in the framework of recombination models. Calibration methods known from silicon detectors were modified and applied. A comparison with data for the pulse-height defect in silicon detectors was performed. (orig.)

  20. Diameter Tuning of Single-Walled Carbon Nanotubes by Diffusion Plasma CVD

    Directory of Open Access Journals (Sweden)

    Toshiaki Kato

    2011-01-01

    Full Text Available We have realized a diameter tuning of single-walled carbon nanotubes (SWNTs by adjusting process gas pressures with plasma chemical vapor deposition (CVD. Detailed photoluminescence measurements reveal that the diameter distribution of SWNTs clearly shifts to a large-diameter region with an increase in the pressure during plasma CVD, which is also confirmed by Raman scattering spectroscopy. Based on the systematical investigation, it is found that the main diameter of SWNTs is determined by the pressure during the heating in an atmosphere of hydrogen and the diameter distribution is narrowed by adjusting the pressure during the plasma generation. Our results could contribute to an application of SWNTs to high-performance thin-film transistors, which requires the diameter-controlled semiconductor-rich SWNTs.

  1. The effect of alkaline doped catalysts on the CVD synthesis of carbon nanotubes

    DEFF Research Database (Denmark)

    Nemeth, Krisztian; Nemeth, Zoltan; Fejes, Dora

    2011-01-01

    The aim of this work was to develop new doped catalysts for chemical vapour deposition (CVD) synthesis in order to increase the quantity and quality of carbon nanotubes (CNTs). Doping compounds such as CsBr, CsCl, KBr and KCl were used to reach higher carbon deposit and carbon yield. The amount o...... of the dopant alkali compounds varied from 1 to 5%. As prepared CNTs were characterized by transmission electron microscopy (TEM), X‐ray diffraction (XRD) and Raman microscopy. Results revealed that both carbon yield and deposit could be increased over doped catalysts.......The aim of this work was to develop new doped catalysts for chemical vapour deposition (CVD) synthesis in order to increase the quantity and quality of carbon nanotubes (CNTs). Doping compounds such as CsBr, CsCl, KBr and KCl were used to reach higher carbon deposit and carbon yield. The amount...

  2. Board diversity and corporate voluntary disclosure (CVD in the annual reports of Bangladesh

    Directory of Open Access Journals (Sweden)

    Md. Abdur Rouf

    2016-10-01

    Full Text Available This is an exploratory study designed to investigate the extant and nature of corporate voluntary disclosure (CVD in corporate annual reports of Bangladesh. Specifically, examine the relationship between board diversity and corporate voluntary disclosures. The paper is based on a sample of 106 listed non-financial companies in Dhaka Stock Exchanges (DSE from the period 2007-2011 and all the companies are selected by Judgment Sampling. The study is used ordinary least squares regression model to examine the relationship between explanatory variables and voluntary disclosure. Using an unweighted relative disclosure index for measuring voluntary disclosure, the empirical results indicate that Percentage Female Director (PFD, Board Leadership Structure (BLS and Total Assets (TA are positively association with corporate voluntary disclosure (CVD. In contrast, the extent of corporate voluntary disclosure is negatively associated with a Percentage of equity owned by the insiders to all equity of the firm higher management ownership

  3. Plasma CVD reactor with two-microwave oscillators for diamond film synthesis

    International Nuclear Information System (INIS)

    Nagatsu, M.; Miyake, M.; Maeda, J.

    2006-01-01

    In this study, we present the experimental results of a new type of microwave plasma CVD system, where two of 1.5 kW microwave sources were used for enlarging the plasma discharge and the diamond film growth. One of the microwave oscillators was used to produce the microwave plasma as in the conventional microwave plasma CVD device, while the second one was used to enlarge the plasma by introducing microwave from the launcher mounted at the substrate stage. We demonstrated the enlargement of plasma discharge area from 60 mm to 100 mm in diameter by using the two-microwave oscillators system. Characteristics of diamond films deposited using H 2 /CH 4 plasmas were also investigated using a scanning electron microscope (SEM) and Raman spectroscopy

  4. Temperature dependence of stress in CVD diamond films studied by Raman spectroscopy

    Directory of Open Access Journals (Sweden)

    Dychalska Anna

    2015-09-01

    Full Text Available Evolution of residual stress and its components with increasing temperature in chemical vapor deposited (CVD diamond films has a crucial impact on their high temperature applications. In this work we investigated temperature dependence of stress in CVD diamond film deposited on Si(100 substrate in the temperature range of 30 °C to 480 °C by Raman mapping measurement. Raman shift of the characteristic diamond band peaked at 1332 cm-1 was studied to evaluate the residual stress distribution at the diamond surface. A new approach was applied to calculate thermal stress evolution with increasing tempera­ture by using two commonly known equations. Comparison of the residts obtained from the two methods was presented. The intrinsic stress component was calculated from the difference between average values of residual and thermal stress and then its temperature dependence was discussed.

  5. Natural and CVD type diamond detectors as dosimeters in hadrontherapy applications

    International Nuclear Information System (INIS)

    Cirrone, G.A.P.; Cuttone, G.; Rafaele, L.; Sabini, M.G.; De Angelis, C.; Onori, S.; Pacilio, M.; Bucciolini, M.; Bruzzi, M.; Sciortino, S.

    2003-01-01

    Diamond is potentially a suitable material for use as radiation dosimeter; the wide band gap results in low dark currents and low sensitivity to visible light, the high carrier mobility can give rapid response, the very high density of strong bonds in the crystal structure make diamond very resistant to radiation damage; moreover it is tissue equivalent. The more recent advances in the synthesis of polycrystalline diamond by chemical vapour deposition (CVD) techniques have allowed the synthesis of material with electronic properties suitable for dosimetric application. In this paper we will report the results obtained in the study of the response of a natural diamond dosimeter and a CVD one irradiated with 62 AMeV proton beams to demonstrate their possible application in protontherapy

  6. Effect of growth temperature and precursor concentration on synthesis of CVD-graphene from camphor

    Science.gov (United States)

    Rajaram, Narasimman; Patel, Biren; Ray, Abhijit; Mukhopadhyay, Indrajit

    2018-05-01

    Here, we have synthesized CVD-graphene from camphor by using atmospheric pressure (AP)-CVD system on Cu foil. We have studied the effect of growth temperature and camphor concentration by using scanning electron microscopy (SEM) and Raman spectroscopy. The domain size of the graphene is increasing with an increase in the temperature and camphor quantity. The complete coverage of graphene on the Cu foil achieved at 1020 °C. Higher camphor quantity leads to growth of multilayer graphene. The graphene is transferred by PMMA-assisted method onto the glass substrate. The sheet resistance and transmittance of the graphene are 1.5 kohm/sq and 92.7%, respectively.

  7. Development of Health Parameter Model for Risk Prediction of CVD Using SVM

    Directory of Open Access Journals (Sweden)

    P. Unnikrishnan

    2016-01-01

    Full Text Available Current methods of cardiovascular risk assessment are performed using health factors which are often based on the Framingham study. However, these methods have significant limitations due to their poor sensitivity and specificity. We have compared the parameters from the Framingham equation with linear regression analysis to establish the effect of training of the model for the local database. Support vector machine was used to determine the effectiveness of machine learning approach with the Framingham health parameters for risk assessment of cardiovascular disease (CVD. The result shows that while linear model trained using local database was an improvement on Framingham model, SVM based risk assessment model had high sensitivity and specificity of prediction of CVD. This indicates that using the health parameters identified using Framingham study, machine learning approach overcomes the low sensitivity and specificity of Framingham model.

  8. Fish consumption and its motives in households with versus without self-reported medical history of CVD

    DEFF Research Database (Denmark)

    Pieniak, Zuzanna; Verbeke, Wim; Perez-Cueto, Federico

    2008-01-01

    subjective and objective knowledge related to nutrition issues about fish. In the other countries, objective knowledge about fish was on a low level, similar for CVD+ as for CVD- subjects, despite a higher claimed use of medical information sources about fish among CVD+ subjects. Conclusions - Although...... consumption. This study exemplifies the need for nutrition education and more effective communication about fish, not only to the people facing chronic diseases, but also to the broader public. European consumers are convinced that eating fish is healthy, but particular emphasis should be made...

  9. Development of Fe-AI CVD coatings as tritium permeation barrier

    International Nuclear Information System (INIS)

    Chabrol, C.; Schuster, F.; Le Marois, G.; Serra, E.

    1998-01-01

    A specific method of pack-cementation has been developed in order to perform a CVD deposition of Fe-Al alloys on a martensitic steel at a temperature which respects its mechanical properties ( 2 Al 5 intermetallic phases thanks to a low pressure deposition and using a special cement containing Fe and Al. These coatings coated with an Al 2 O 3 top layer drastically reduce the permeation rate of deuterium with regards to the uncoated substrate. (authors)

  10. Growth and characterization of nanodiamond layers prepared using plasma enhanced linear antennas microwave CVD system

    Czech Academy of Sciences Publication Activity Database

    Fendrych, František; Taylor, Andrew; Peksa, Ladislav; Kratochvílová, Irena; Vlček, J.; Řezáčová, V.; Petrák, V.; Kluiber, Z.; Fekete, Ladislav; Liehr, M.; Nesládek, M.

    2010-01-01

    Roč. 43, č. 37 (2010), 374018/1-374018/6 ISSN 0022-3727 R&D Projects: GA AV ČR KAN200100801; GA AV ČR KAN300100801; GA AV ČR KAN301370701 Institutional research plan: CEZ:AV0Z10100520 Keywords : nanodiamond, * thin films * PE MW CVD * linear antennas Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.105, year: 2010

  11. Mediators and Moderators of Dementia Caregiver Depression and CVD Risk Outcomes in the Pleasant Events Program

    OpenAIRE

    Ho, Jennefer S.

    2016-01-01

    Rationale: Alzheimer’s disease caregivers demonstrate significant elevations in depression compared with noncaregivers. Addressing caregiver depression is of high public health importance due to its ties with overall wellbeing, increased risk for cardiovascular diseases (CVD), and ability to sustain caregiving duties. Improving caregiver mental and physical health may not only decrease healthcare costs, but it may also delay institutionalization of Alzheimer’s disease patients. Despite existi...

  12. A 3D tomographic EBSD analysis of a CVD diamond thin film

    International Nuclear Information System (INIS)

    Liu Tao; Raabe, Dierk; Zaefferer, Stefan

    2008-01-01

    We have studied the nucleation and growth processes in a chemical vapor deposition (CVD) diamond film using a tomographic electron backscattering diffraction method (3D EBSD). The approach is based on the combination of a focused ion beam (FIB) unit for serial sectioning in conjunction with high-resolution EBSD. Individual diamond grains were investigated in 3-dimensions particularly with regard to the role of twinning.

  13. A 3D tomographic EBSD analysis of a CVD diamond thin film

    Directory of Open Access Journals (Sweden)

    Tao Liu, Dierk Raabe and Stefan Zaefferer

    2008-01-01

    Full Text Available We have studied the nucleation and growth processes in a chemical vapor deposition (CVD diamond film using a tomographic electron backscattering diffraction method (3D EBSD. The approach is based on the combination of a focused ion beam (FIB unit for serial sectioning in conjunction with high-resolution EBSD. Individual diamond grains were investigated in 3-dimensions particularly with regard to the role of twinning.

  14. Cold Vacuum Dryer (CVD) Facility Security System Design Description. System 54

    International Nuclear Information System (INIS)

    WHITEHURST, R.

    2000-01-01

    This system design description (SDD) addresses the Cold Vacuum Drying (CVD) Facility security system. The system's primary purpose is to provide reasonable assurance that breaches of security boundaries are detected and assessment information is provided to protective force personnel. In addition, the system is utilized by Operations to support reduced personnel radiation goals and to provide reasonable assurance that only authorized personnel are allowed to enter designated security areas

  15. The Role of Built Environments in Physical Activity, Obesity, and CVD

    OpenAIRE

    Sallis, James F.; Floyd, Myron F.; Rodríguez, Daniel A.; Saelens, Brian E.

    2012-01-01

    In industrialized nations like the United States and Sweden, the vast majority of adults do not meet the physical activity guidelines of 150 minutes per week.1 Inactive lifestyles put most adults at risk of cardiovascular diseases (CVD), diabetes, obesity, some cancers, osteoporosis, and psychological disorders.2 Physical activity can be effective at all phases of chronic disease management, from primordial prevention (prevention of risk factors) through treatment and rehabilitation.2 There i...

  16. Growth of carbon allotropes and plasma characterization in linear antenna microwave plasma CVD system

    Czech Academy of Sciences Publication Activity Database

    Potocký, Štěpán; Babchenko, Oleg; Davydova, Marina; Ižák, Tibor; Čada, Martin; Kromka, Alexander

    2014-01-01

    Roč. 53, č. 5 (2014), "05FP04-1"-"05FP04-3" ISSN 0021-4922 R&D Projects: GA TA ČR TA01011740; GA ČR GAP205/12/0908 Grant - others:AVČR(CZ) M100100902 Institutional support: RVO:68378271 Keywords : antenna linear * CVD system * plasma Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.127, year: 2014

  17. Preparación de tamices moleculares de carbono por CVD

    OpenAIRE

    Manso, R.; Pajares, J. A.; Albiniak, A.; Broniek, E.; Siemieniewska, T.

    2001-01-01

    Carbon molecular sieves (CMS) have been prepared by chemical vapour deposition (CVD) of carbon from the pyrolysis of benzene molecules on activated carbon surfaces. The pyrolysis of benzene at temperatures in the range 650-850 ºC restricts the accessibility of the micropores due to the creation of constrictions on the microporous network. Temperatures higher than 850 ºC (temperature of carbonisation) add difficulties due to decomposition and sinterization processes. Low flows of nitrogen (30 ...

  18. Nanocrystalline sp{sup 2} and sp{sup 3} carbons: CVD synthesis and applications

    Energy Technology Data Exchange (ETDEWEB)

    Terranova, M. L. [Università degli Studi di Roma “Tor Vergata,” via Della Ricerca Scientifica, Dipartimento di Scienze e Tecnologie Chimiche—MinimaLab (Italy); Rossi, M. [Università degli Studi di Roma “Sapienza,” via A. Scarpa, Dipartimento di Scienze di Base e Applicate per l’Ingegneria and Centro di Ricerca per le Nanotecnologie Applicate all’Ingegneria (CNIS) (Italy); Tamburri, E., E-mail: emanuela.tamburri@uniroma2.it [Università degli Studi di Roma “Tor Vergata,” via Della Ricerca Scientifica, Dipartimento di Scienze e Tecnologie Chimiche—MinimaLab (Italy)

    2016-11-15

    The design and production of innovative materials based on nanocrystalline sp{sup 2}- and sp{sup 3}-coordinated carbons is presently a focus of the scientific community. We present a review of the nanostructures obtained in our labs using a series of synthetic routes, which make use of chemical vapor deposition (CVD) techniques for the selective production of non-planar graphitic nanostructures, nanocrystalline diamonds, and hybrid two-phase nanostructures.

  19. CVD Diamond Detectors for Current Mode Neutron Time-of-Flight Spectroscopy at OMEGA/NIF

    International Nuclear Information System (INIS)

    G. J. Schmid; V. Yu. Glebov; A. V. Friensehner; D. R. Hargrove; S. P. Hatchett; N. Izumi; R. A. Lerche; T. W. Phillips; T. C. Sangster; C. Silbernagel; C. Stoecki

    2001-01-01

    We have performed pulsed neutron and pulsed laser tests of a CVD diamond detector manufactured from DIAFILM, a commercial grade of CVD diamond. The laser tests were performed at the short pulse UV laser at Bechtel Nevada in Livermore, CA. The pulsed neutrons were provided by DT capsule implosions at the OMEGA laser fusion facility in Rochester, NY. From these tests, we have determined the impulse response to be 250 ps fwhm for an applied E-field of 500 V/mm. Additionally, we have determined the sensitivity to be 2.4 mA/W at 500 V/mm and 4.0 mA/W at 1000 V/mm. These values are approximately 2 to 5x times higher than those reported for natural Type IIa diamond at similar E-field and thickness (1mm). These characteristics allow us to conceive of a neutron time-of-flight current mode spectrometer based on CVD diamond. Such an instrument would sit inside the laser fusion target chamber close to target chamber center (TCC), and would record neutron spectra fast enough such that backscattered neutrons and x-rays from the target chamber wall would not be a concern. The acquired neutron spectra could then be used to extract DD fuel areal density from the downscattered secondary to secondary ratio

  20. Topographic and spectroscopic characterization of electronic edge states in CVD grown graphene nanoribbons.

    Science.gov (United States)

    Pan, Minghu; Girão, E Costa; Jia, Xiaoting; Bhaviripudi, Sreekar; Li, Qing; Kong, Jing; Meunier, V; Dresselhaus, Mildred S

    2012-04-11

    We used scanning tunneling microscopy and spectroscopy (STM/S) techniques to analyze the relationships between the edge shapes and the electronic structures in as-grown chemical vapor deposition (CVD) graphene nanoribbons (GNRs). A rich variety of single-layered graphene nanoribbons exhibiting a width of several to 100 nm and up to 1 μm long were studied. High-resolution STM images highlight highly crystalline nanoribbon structures with well-defined and clean edges. Theoretical calculations indicate clear spin-split edge states induced by electron-electron Coulomb repulsion. The edge defects can significantly modify these edge states, and different edge structures for both sides of a single ribbon produce asymmetric electronic edge states, which reflect the more realistic features of CVD grown GNRs. Three structural models are proposed and analyzed to explain the observations. By comparing the models with an atomic resolution image at the edge, a pristine (2,1) structure was ruled out in favor of a reconstructed edge structure composed of 5-7 member rings, showing a better match with experimental results, and thereby suggesting the possibility of a defective morphology at the edge of CVD grown nanoribbons. © 2012 American Chemical Society

  1. Freedom poverty: a new tool to identify the multiple disadvantages affecting those with CVD.

    Science.gov (United States)

    Callander, Emily J; Schofield, Deborah J; Shrestha, Rupendra N

    2013-06-20

    It is recognised that CVD affects an individual's financial situation, placing them in income poverty. However, recent developments in poverty measurement practice recognises other forms of disadvantage other than low income, such as poor health and insufficient education also affect living standards. Using the Freedom Poverty Measure, the multiple forms of disadvantage experienced by those with no health condition, heart disease, other diseases of the circulatory system, and all other health conditions was assessed using data on the adult Australian population contained in the 2003 Survey of Disability, Ageing and Carers. 24% of those with heart disease and 23% of those with other diseases of the circulatory system were in freedom poverty, suffering from multiple forms of disadvantage. Those with heart disease and those with other diseases of the circulatory system were around three times more likely to be in freedom poverty (OR 3.02, 95% CI: 2.29-3.99, p<.0001; OR 2.78, 95% CI: 1.94-3.98, p<.0001) than those with no health condition. Recognising the multiple forms of disadvantage suffered by those with CVD provides a clearer picture of their living standards than just looking at their income alone and the high proportion of individuals with CVD that are suffering from multiple forms of disadvantage should make them a target for policy makers wishing to improve living standards. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. Which population groups are most unaware of CVD risks associated with sitting time?

    Science.gov (United States)

    Duncan, Mitch J; Gilson, Nicholas; Vandelanotte, Corneel

    2014-08-01

    Prolonged sitting is an emerging risk factor for poor health yet few studies have examined awareness of the risks associated with sitting behaviours. This study identifies the population subgroups with the highest levels of unawareness regarding the cardiovascular disease (CVD) risks associated with sitting behaviours. Adults (n=1256) living in Queensland, Australia completed a telephone-based survey in 2011, analysis conducted in 2013. The survey assessed participant's socio-demographic characteristics, physical activity, sitting behaviours and awareness of CVD risks associated with three sitting behaviours: 1) sitting for prolonged periods, 2), sitting for prolonged periods whilst also engaging in regular physical activity, and 3) breaking up periods of prolonged sitting with short activity breaks. Population sub-groups with the highest levels of unawareness were identified based on socio-demographic and behavioural characteristics using signal detection analysis. Unawareness ranged from 23.3% to 67.0%. Age was the most important variable in differentiating awareness levels; younger adults had higher levels of unawareness. Body mass index, physical activity, TV viewing, employment status and time spent at work also identified population sub-groups. Unawareness of CVD risk for prolonged sitting was moderately high overall. Younger adults had high levels of unawareness on all of the outcomes examined. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Mechanics-driven patterning of CVD graphene for roll-based manufacturing process

    Science.gov (United States)

    Kim, Sang-Min; Jang, Bongkyun; Jo, Kyungmin; Kim, Donghyuk; Lee, Jihye; Kim, Kyung-Shik; Lee, Seung-Mo; Lee, Hak-Joo; Han, Seung Min; Kim, Jae-Hyun

    2017-06-01

    Graphene is considered as a promising material for flexible and transparent electrodes due to its outstanding electrical, optical, and mechanical properties. Efforts to mass-produce graphene electrodes led to the development of roll-to-roll chemical vapor deposition (CVD) graphene growth and transfer, and the only remaining obstacle to the mass-production of CVD graphene electrodes is a cost-effective patterning technique that is compatible with the roll-to-roll manufacturing. Herein, we propose a mechanics-driven technique for patterning graphene synthesized on copper foil (commonly used in roll-to-roll manufacturing). The copper foil is exposed to high temperature for a prolonged period during the CVD growth of graphene, and thus can result in recrystallization and grain growth of the copper foil and thereby reducing to the yield strength. This softening behavior of the copper was carefully controlled to allow simple stamp patterning of the graphene. The strength of the underlying substrate was controlled for the accuracy of the residual patterns. The proposed stamp patterning technique is mask-less and photoresist-free, and can be performed at room temperature without high-energy sources such as lasers or plasma. To demonstrate the capability of this process to produce a continuous electrode, a transparent in-plane supercapacitor was fabricated using the proposed patterning technique.

  4. Direct CVD Graphene Growth on Semiconductors and Dielectrics for Transfer-Free Device Fabrication.

    Science.gov (United States)

    Wang, Huaping; Yu, Gui

    2016-07-01

    Graphene is the most broadly discussed and studied two-dimensional material because of its preeminent physical, mechanical, optical, and thermal properties. Until now, metal-catalyzed chemical vapor deposition (CVD) has been widely employed for the scalable production of high-quality graphene. However, in order to incorporate the graphene into electronic devices, a transfer process from metal substrates to targeted substrates is inevitable. This process usually results in contamination, wrinkling, and breakage of graphene samples - undesirable in graphene-based technology and not compatible with industrial production. Therefore, direct graphene growth on desired semiconductor and dielectric substrates is considered as an effective alternative. Over the past years, there have been intensive investigations to realize direct graphene growth using CVD methods without the catalytic role of metals. Owing to the low catalytic activity of non-metal substrates for carbon precursor decomposition and graphene growth, several strategies have been designed to facilitate and engineer graphene fabrication on semiconductors and insulators. Here, those developed strategies for direct CVD graphene growth on semiconductors and dielectrics for transfer-free fabrication of electronic devices are reviewed. By employing these methods, various graphene-related structures can be directly prepared on desired substrates and exhibit excellent performance, providing versatile routes for varied graphene-based materials fabrication. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Crystalline silicon thin film growth by ECR plasma CVD for solar cells

    International Nuclear Information System (INIS)

    Licai Wang

    1999-07-01

    This thesis describes the background, motivation and work carried out towards this PhD programme entitled 'Crystalline Silicon Thin Film Growth by ECR Plasma CVD for Solar Cells'. The fundamental principles of silicon solar cells are introduced with a review of silicon thin film and bulk solar cells. The development and prospects for thin film silicon solar cells are described. Some results of a modelling study on thin film single crystalline solar cells are given which has been carried out using a commercially available solar cell simulation package (PC-1D). This is followed by a description of thin film deposition techniques. These include Chemical Vapour Deposition (CVD) and Plasma-Assisted CVD (PACVD). The basic theory and technology of the emerging technique of Electron Cyclotron Resonance (ECR) PACVD, which was used in this research, are introduced and the potential advantages summarised. Some of the basic methods of material and cell characterisation are briefly described, together with the work carried out in this research. The growth by ECR PACVD at temperatures 2 illumination. The best efficiency in the ECR grown structures was 13.76% using an epitaxial emitter. Cell performance was analysed in detail and the factors controlling performance identified by fitting self-consistently the fight and dark current-voltage and spectral response data using PC-1D. Finally, the conclusions for this research and suggestions for further work are outlined. (author)

  6. Proton irradiation of CVD diamond detectors for high-luminosity experiments at the LHC

    Science.gov (United States)

    Meier, D.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Foulon, F.; Friedl, M.; Jany, C.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Knöpfle, K. T.; Krammer, M.; Manfredi, P. F.; Marshall, R. D.; Mishina, M.; Le Normand, F.; Pan, L. S.; Palmieri, V. G.; Pernegger, H.; Pernicka, M.; Peitz, A.; Pirollo, S.; Pretzl, K.; Re, V.; Riester, J. L.; Roe, S.; Roff, D.; Rudge, A.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R. J.; Tesarek, R.; Thomson, G. B.; Trawick, M.; Trischuk, W.; Turchetta, R.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Ziock, H.; Zoeller, M.; RD42 Collaboration

    1999-04-01

    CVD diamond shows promising properties for use as a position-sensitive detector for experiments in the highest radiation areas at the Large Hadron Collider. In order to study the radiation hardness of diamond we exposed CVD diamond detector samples to 24 Gev/ c and 500 Mev protons up to a fluence of 5×10 15 p/cm 2. We measured the charge collection distance, the average distance electron-hole pairs move apart in an external electric field, and leakage currents before, during, and after irradiation. The charge collection distance remains unchanged up to 1×10 15 p/cm 2 and decreases by ≈40% at 5×10 15 p/cm 2. Leakage currents of diamond samples were below 1 pA before and after irradiation. The particle-induced currents during irradiation correlate well with the proton flux. In contrast to diamond, a silicon diode, which was irradiated for comparison, shows the known large increase in leakage current. We conclude that CVD diamond detectors are radiation hard to 24 GeV/ c and 500 MeV protons up to at least 1×10 15p/cm 2 without signal loss.

  7. Proton irradiation of CVD diamond detectors for high-luminosity experiments at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Meier, D. E-mail: dirk.meier@cern.ch.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Foulon, F.; Friedl, M.; Jany, C.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Knoepfle, K.T.; Krammer, M.; Manfredi, P.F.; Marshall, R.D.; Mishina, M.; Le Normand, F.; Pan, L.S.; Palmieri, V.G.; Pernegger, H.; Pernicka, M.; Peitz, A.; Pirollo, S.; Pretzl, K.; Re, V.; Riester, J.L.; Roe, S.; Roff, D.; Rudge, A.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R.J.; Tesarek, R.; Thomson, G.B.; Trawick, M.; Trischuk, W.; Turchetta, R.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Ziock, H.; Zoeller, M

    1999-04-21

    CVD diamond shows promising properties for use as a position-sensitive detector for experiments in the highest radiation areas at the Large Hadron Collider. In order to study the radiation hardness of diamond we exposed CVD diamond detector samples to 24 Gev/c and 500 Mev protons up to a fluence of 5x10{sup 15} p/cm{sup 2}. We measured the charge collection distance, the average distance electron-hole pairs move apart in an external electric field, and leakage currents before, during, and after irradiation. The charge collection distance remains unchanged up to 1x10{sup 15} p/cm{sup 2} and decreases by {approx}40% at 5x10{sup 15} p/cm{sup 2}. Leakage currents of diamond samples were below 1 pA before and after irradiation. The particle-induced currents during irradiation correlate well with the proton flux. In contrast to diamond, a silicon diode, which was irradiated for comparison, shows the known large increase in leakage current. We conclude that CVD diamond detectors are radiation hard to 24 GeV/c and 500 MeV protons up to at least 1x10{sup 15}p/cm{sup 2} without signal loss.

  8. Proton irradiation of CVD diamond detectors for high-luminosity experiments at the LHC

    International Nuclear Information System (INIS)

    Meier, D.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Foulon, F.; Friedl, M.; Jany, C.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Knoepfle, K.T.; Krammer, M.; Manfredi, P.F.; Marshall, R.D.; Mishina, M.; Le Normand, F.; Pan, L.S.; Palmieri, V.G.; Pernegger, H.; Pernicka, M.; Peitz, A.; Pirollo, S.; Pretzl, K.; Re, V.; Riester, J.L.; Roe, S.; Roff, D.; Rudge, A.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R.J.; Tesarek, R.; Thomson, G.B.; Trawick, M.; Trischuk, W.; Turchetta, R.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Ziock, H.; Zoeller, M.

    1999-01-01

    CVD diamond shows promising properties for use as a position-sensitive detector for experiments in the highest radiation areas at the Large Hadron Collider. In order to study the radiation hardness of diamond we exposed CVD diamond detector samples to 24 Gev/c and 500 Mev protons up to a fluence of 5x10 15 p/cm 2 . We measured the charge collection distance, the average distance electron-hole pairs move apart in an external electric field, and leakage currents before, during, and after irradiation. The charge collection distance remains unchanged up to 1x10 15 p/cm 2 and decreases by ∼40% at 5x10 15 p/cm 2 . Leakage currents of diamond samples were below 1 pA before and after irradiation. The particle-induced currents during irradiation correlate well with the proton flux. In contrast to diamond, a silicon diode, which was irradiated for comparison, shows the known large increase in leakage current. We conclude that CVD diamond detectors are radiation hard to 24 GeV/c and 500 MeV protons up to at least 1x10 15 p/cm 2 without signal loss

  9. Proton Irradiation of CVD Diamond Detectors for High Luminosity Experiments at the LHC

    CERN Document Server

    Meier, D; Bauer, C; Berdermann, E; Bergonzo, P; Bogani, F; Borchi, E; Bruzzi, Mara; Colledani, C; Conway, J; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Grigoriev, E A; Hallewell, G D; Hall-Wilton, R; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Jany, C; Kagan, H; Kania, D R; Kaplon, J; Kass, R; Knöpfle, K T; Krammer, Manfred; Manfredi, P F; Marshall, R D; Mishina, M; Le Normand, F; Pan, L S; Palmieri, V G; Pernegger, H; Pernicka, Manfred; Peitz, A; Pirollo, S; Pretzl, Klaus P; Re, V; Riester, J L; Roe, S; Roff, D G; Rudge, A; Schnetzer, S R; Sciortino, S; Speziali, V; Stelzer, H; Stone, R; Tapper, R J; Tesarek, R J; Thomson, G B; Trawick, M L; Trischuk, W; Turchetta, R; Walsh, A M; Wedenig, R; Weilhammer, Peter; Ziock, H J; Zöller, M

    1999-01-01

    CVD diamond shows promising properties for use as a position sensitive detector for experiments in the highest radiation areas at the Large Hadron Collider. In order to study the radiation hardn ess of diamond we exposed CVD diamond detector samples to 24~GeV/$c$ and 500~MeV protons up to a fluence of $5\\times 10^{15}~p/{\\rm cm^2}$. We measured the charge collection distance, the ave rage distance electron hole pairs move apart in an external electric field, and leakage currents before, during, and after irradiation. The charge collection distance remains unchanged up to $1\\ times 10^{15}~p/{\\rm cm^2}$ and decreases by $\\approx$40~\\% at $5\\times 10^{15}~p/{\\rm cm^2}$. Leakage currents of diamond samples were below 1~pA before and after irradiation. The particle indu ced currents during irradiation correlate well with the proton flux. In contrast to diamond, a silicon diode, which was irradiated for comparison, shows the known large increase in leakage curren t. We conclude that CVD diamond detectors are radia...

  10. Convection and chemistry effects in CVD: A 3-D analysis for silicon deposition

    Science.gov (United States)

    Gokoglu, S. A.; Kuczmarski, M. A.; Tsui, P.; Chait, A.

    1989-01-01

    The computational fluid dynamics code FLUENT has been adopted to simulate the entire rectangular-channel-like (3-D) geometry of an experimental CVD reactor designed for Si deposition. The code incorporated the effects of both homogeneous (gas phase) and heterogeneous (surface) chemistry with finite reaction rates of important species existing in silane dissociation. The experiments were designed to elucidate the effects of gravitationally-induced buoyancy-driven convection flows on the quality of the grown Si films. This goal is accomplished by contrasting the results obtained from a carrier gas mixture of H2/Ar with the ones obtained from the same molar mixture ratio of H2/He, without any accompanying change in the chemistry. Computationally, these cases are simulated in the terrestrial gravitational field and in the absence of gravity. The numerical results compare favorably with experiments. Powerful computational tools provide invaluable insights into the complex physicochemical phenomena taking place in CVD reactors. Such information is essential for the improved design and optimization of future CVD reactors.

  11. Increased risk of cardiovascular disease (CVD) with age in HIV-positive men

    DEFF Research Database (Denmark)

    Petoumenos, K; Reiss, P; Ryom, L

    2014-01-01

    equations. METHODS: We analysed three endpoints: myocardial infarction (MI), coronary heart disease (CHD: MI or invasive coronary procedure) and CVD (CHD or stroke). We fitted a number of parametric age effects, adjusting for known risk factors and antiretroviral therapy (ART) use. The best-fitting age...... rates per 1000 person-years increased from 2.29, 3.11 and 3.65 in those aged 40-45 years to 6.53, 11.91 and 15.89 in those aged 60-65 years, respectively. The best-fitting models included inverse age for MI and age + age(2) for CHD and CVD. In D:A:D there was a slowly accelerating increased risk of CHD...... and CVD per year older, which appeared to be only modest yet was consistently raised compared with the risk in the general population. The relative risk of MI with age was not different between D:A:D and the general population. CONCLUSIONS: We found only limited evidence of accelerating increased risk...

  12. CVD of alternated microcrystalline (MCD) and nanocrystalline (NCD) diamond films on WC-TIC-CO substrates

    International Nuclear Information System (INIS)

    Campos, Raonei Alves; Contin, Andre; Trava-Airoldi, Vladimir J.; Corat, Evaldo Jose; Barquete, Danilo Maciel

    2010-01-01

    CVD Diamond coating of WC-TiC-Co cutting tools has been an alternative to increase tool lifetime. Experiments have shown that residual stresses produced during films growth on WC-TiC-Co substrates significantly increases with increasing film thickness up to 20 μm and usually leads to film delamination. In this work alternated micro- and nanocrystalline CVD diamond films have been used to relax interface stresses and to increase diamond coatings performance. WC-TiC-Co substrates have been submitted to a boronizing thermal diffusion treatment prior to CVD diamond films growth. After reactive heat treatment samples were submitted to chemical etching in acid and alkaline solution. The diamond films deposition was performed using HFCVD reactor with different gas concentrations for microcrystalline (MCD) and nano-crystalline (NCD) films growth. As a result, we present the improvement of diamond films adherence on WC-TiC-Co, evaluated by indentation and machining tests. Samples were characterized by Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray (EDX) for qualitative analysis of diamond films. X-ray Diffraction (XRD) was used for phases identification after boronizing process. Diamond film compressive residual stresses were analyzed by Raman Scattering Spectroscopy (RSS). (author)

  13. A CVD Diamond Detector for (n,a) Cross-Section Measurements

    CERN Document Server

    Weiss, Christina; Griesmayer, Erich; Guerrero, Carlos

    A novel detector based on the chemical vapor deposition (CVD) diamond technology has been developed in the framework of this PhD, for the experimental determination of (n,a) cross-sections at the neutron time-of-flight facility n_TOF at CERN. The 59Ni(n,a)56Fe cross-section, which is relevant for astrophysical questions as well as for risk-assessment studies in nuclear technology, has been measured in order to validate the applicability of the detector for such experiments. The thesis is divided in four parts. In the introductory part the motivation for measuring (n,a) cross-sections, the experimental challenges for such measurements and the reasons for choosing the CVD diamond technology for the detector are given. This is followed by the presentation of the n_TOF facility, an introduction to neutron-induced nuclear reactions and a brief summary of the interaction of particles with matter. The CVD diamond technology and the relevant matters related to electronics are given as well in this first part of the t...

  14. RF characteristic of MESFET on H-terminated DC arc jet CVD diamond film

    International Nuclear Information System (INIS)

    Liu, J.L.; Li, C.M.; Zhu, R.H.; Guo, J.C.; Chen, L.X.; Wei, J.J.; Hei, L.F.; Wang, J.J.; Feng, Z.H.; Guo, H.; Lv, F.X.

    2013-01-01

    Diamond has been considered to be a potential material for high-frequency and high-power electronic devices due to the excellent electrical properties. In this paper, we reported the radio frequency (RF) characteristic of metal-semiconductor field effect transistor (MESFET) on polycrystalline diamond films prepared by direct current (DC) arc jet chemical vapor deposition (CVD). First, 4 in polycrystalline diamond films were deposited by DC arc jet CVD in gas recycling mode with the deposition rate of 14 μm/h. Then the polished diamond films were treated by microwave hydrogen plasma and the 0.2 μm-gate-length MESFET was fabricated by using Au mask photolithography and electron beam (EB) lithography. The surface conductivity of the H-terminated diamond film and DC and RF performances of the MESFET were characterized. The results demonstrate that, the carrier mobility of 24.6 cm 2 /V s and the carrier density of 1.096 × 10 13 cm −2 are obtained on the surface of H-terminated diamond film. The FET shows the maximum transition frequency (f T ) of 5 GHz and the maximum oscillation frequency (f max ) of 6 GHz at V GS = −0.5 V and V DS = −8 V, which indicates that H-terminated DC arc jet CVD polycrystalline diamond is suitable for the development of high frequency devices.

  15. Coffee consumption is not associated with prevalent subclinical cardiovascular disease (CVD) or the risk of CVD events, in nonalcoholic fatty liver disease: Results from the multi-ethnic study of atherosclerosis

    Science.gov (United States)

    Atherosclerosis and its clinical sequelae represent the leading cause of mortality among patients with nonalcoholic fatty liver disease (NAFLD). While epidemiologic data support the hepatoprotective benefits of coffee in NAFLD, whether coffee improves NAFLD-associated Cardiovascular Disease (CVD) ri...

  16. Adherence to a healthy diet in relation to cardiovascular incidence and risk markers: evidence from the Caerphilly Prospective Study.

    Science.gov (United States)

    Mertens, Elly; Markey, Oonagh; Geleijnse, Johanna M; Lovegrove, Julie A; Givens, D Ian

    2018-04-01

    Epidemiological findings indicate that higher adherence to a healthy diet may lower cardiovascular disease (CVD) risk. The present study aimed to investigate whether adherence to a healthy diet, assessed by the Healthy Diet Indicator (HDI), Dietary Approaches to Stop Hypertension (DASH) score, and Alternative Healthy Eating Index 2010 (AHEI-2010), was associated with CVD incidence and risk markers. Included in the present analyses were data from 1867 middle-aged men, aged 56.7 ± 4.5 years at baseline, recruited into the Caerphilly Prospective Study. Adherence to a healthy diet was examined in relation to CVD, coronary heart disease (CHD), and stroke incidence (Cox regression), and risk markers (linear regression) with adjustment for relevant confounders. The DASH score was inversely associated with CVD [hazard ratio (HR) 0.81; 95% confidence interval (CI) 0.66, 0.99], and stroke (HR 0.61; 95% CI 0.42, 0.88) incidence, but not with CHD after an average of 16.6 year follow-up, and with diastolic blood pressure, after 12 year follow-up. The AHEI-2010 was inversely associated with stroke (HR 0.66; 95% CI 0.42, 0.88) incidence, aortic pulse wave velocity, and C-reactive protein. The HDI was not associated with any single outcome. Higher DASH and AHEI-2010 scores were associated with lower CVD and stroke risk, and favourable cardiovascular health outcomes, suggesting that encouraging middle-aged men to comply with the dietary recommendations for a healthy diet may have important implications for future vascular disease and population health.

  17. Higher plasma levels of advanced glycation end products are associated with incident cardiovascular disease and all-cause mortality in type 1 diabetes

    DEFF Research Database (Denmark)

    Nin, Johanna W; Jorsal, Anders; Ferreira, Isabel

    2011-01-01

    -grade inflammation, and arterial stiffness. RESEARCH DESIGN AND METHODS: We prospectively followed 169 individuals with diabetic nephropathy and 170 individuals with persistent normoalbuminuria who were free of CVD at study entry and in whom levels of N(ε)-(carboxymethyl)lysine, N(ε)-(carboxyethyl)lysine......OBJECTIVE: To investigate the associations of plasma levels of advanced glycation end products (AGEs) with incident cardiovascular disease (CVD) and all-cause mortality in type 1 diabetes and the extent to which any such associations could be explained by endothelial and renal dysfunction, low...... or endothelial dysfunction, low-grade inflammation, or arterial stiffness. CONCLUSIONS: Higher levels of AGEs are associated with incident fatal and nonfatal CVD as well as all-cause mortality in individuals with type 1 diabetes, independently of other risk factors and of several potential AGEs...

  18. Proposed classification scale for radiological incidents and accidents; Elaboration d'une echelle de classement des incidents et accidents radiologiques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-04-15

    The scale proposed in this report is intended to facilitate communication concerning the severity of incidents and accidents involving the exposure of human beings to ionising radiations. Like the INES, it comprises eight levels of severity and uses the same terms (accident, incident, anomaly, serious and major) for keeping the public and the media informed. In a radiological protection context, the severity of an event is considered as being directly proportional to the risk run by an individual (the probability of developing fatal or non-fatal health effects) following exposure to ionising radiation in an incident or accident situation. However for society, other factors have to be taken into account to determine severity. The severity scale proposed is therefore based on assessment of the individual radiological risk. A severity level corresponding to exposure of a member of the public in an incident or accident situation is determined on the basis of risk assessment concepts and methods derived from international consensus on dose/effect relationships for both stochastic and deterministic effects. The severity of all the possible exposure situations - worker exposure, collective exposure, potential exposure - is determined using a system of weighting in relation to situations involving members of the public. In the case of this scale, to indicate the severity of an event, it is proposed to make use of the most penalizing level of severity, comparing: - the severity associated with the probability of occurrence of deterministic effects and the severity associated with the probability of occurrence of stochastic effects, when the event gives rise to both types of risk; - the severity for members of the public and the severity for exposed workers, when both categories of individuals are involved; - the severity on the proposed radiological protection scale and that obtained using the INES, when radiological protection and nuclear safety aspects are associated with

  19. Laser-Directed CVD 3D Printing System for Refractory Metal Propulsion Hardware, Phase II, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this work, Ultramet is developing a three-dimensional (3D) laser-directed chemical vapor deposition (CVD) additive manufacturing system to build free-form...

  20. Incident Information Management Tool

    CERN Document Server

    Pejovic, Vladimir

    2015-01-01

    Flaws of\tcurrent incident information management at CMS and CERN\tare discussed. A new data\tmodel for future incident database is\tproposed and briefly described. Recently developed draft version of GIS-­‐based tool for incident tracking is presented.

  1. Industrial science and technology research and development project of university cooperative type in fiscal 2000. Report on achievements in semiconductor device manufacturing processes using Cat-CVD method (Semiconductor device manufacturing processes using Cat-CVD method); 2000 nendo daigaku renkeigata sangyo kagaku gijutsu kenkyu kaihatsu project. Cat-CVD ho ni yoru handotai device seizo process seika hokokusho (Cat-CVD ho ni yoru handotai device seizo process)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The catalytic chemical vapor deposition (Cat-CVD) method is a low-temperature thin film depositing technology that can achieve improvement in quality of semiconductor thin films and can perform inexpensive film deposition in a large area. The present project is composed of the basic research and development theme and the demonstrative research and development theme for the Cat-CVD method. This report summarizes the achievements in fiscal 2000 centering on the former theme. Discussions were given on the following five areas: 1) simulation on film thickness distribution in the Cat-CVD method, 2) life extension by preventing the catalyst converting into silicide and development of a catalyst integrated shear head, 3) vapor diagnosis in the film forming process by the Cat-CVD method using silane, hydrogen and ammonia, 4) a technology for high-speed deposition of hydrogenated amorphous silicon films for solar cells using the Cat-CVD method, and the low-temperature silicon oxide nitriding technology using heated catalysts, and 5) discussions on compatibility of transparent oxide electrode materials to the process of manufacturing thin-film silicon-based solar cells by using the Cat-CVD method. (NEDO)

  2. Exploring the path between depression, anxiety and 10-year cardiovascular disease incidence, among apparently healthy Greek middle-aged adults: The ATTICA study.

    Science.gov (United States)

    Kollia, Natasa; Panagiotakos, Demosthenes; Georgousopoulou, Ekavi; Chrysohoou, Christina; Yannakoulia, Mary; Stefanadis, Christodoulos; Chatterji, Somnath; Haro, Josep Maria; Papageorgiou, Charalabos; Pitsavos, Christos

    2017-12-01

    Although there is substantial evidence that psychological factors play an important role in the onset and course of cardiovascular disease (CVD), less is known about their combined effect and the pathways by which they affect cardiovascular health. The present work aimed to prospectively explore the effects of depression and anxiety on the 10-year CVD incidence, in relation to other lifestyle determinants, as linking factors in the context of the ATTICA study. Study design/Main outcome measures: The ATTICA study is a population-based, health and nutrition prospective cohort study (2002-2012), during which 853 middle-aged participants without a history of CVD [453 men (aged 45±13years) and 400 women (aged 44±18years)], underwent psychological evaluations at enrollment. The latent trait of depression and anxiety combined measure was estimated and referred as "Psychological distress"; path analysis was applied to describe the relationships among the different factors. "Psychological distress" was positively associated with the 10-year CVD incidence (adjusted OR per 10 units: 1.4, 95% CI: 1.1, 1.7). Three linking pathways were revealed: sedentariness, inflammation and metabolic syndrome. Moreover, "Psychological distress" mediated the association between socioeconomic status (SES) and CVD, with participants of low SES scoring higher on the psychological measure (adjusted linear regression coefficient b: -7.1, 95% CI: -9.7, -4.5). Lifestyle and clinical factors seem to link psychological distress with CVD development. Joint psychological assessments should be considered for inclusion in CVD preventive strategies, which should incorporate interventions for interrupting the linking pathways. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Comparación de las lesiones no mortales por accidente de trabajo por Comunidades Autónomas en España (1994-2004 Comparison of non-fatal occupational injuries by autonomous communities in Spain (1994-2004

    Directory of Open Access Journals (Sweden)

    María López-Ruiz

    2009-12-01

    Full Text Available Objetivos: Dadas las diferencias observadas en estudios previos de la incidencia de lesiones por accidente de trabajo (LAT por Comunidades Autónomas (CC.AA., en este estudio hemos evaluado la hipótesis de homogeneidad de la incidencia de las LAT para tipos específicos de accidentes y en determinadas actividades, entre 1994 y 2004. Métodos: Las LAT analizadas fueron no mortales con baja, de tipo mecánico y sobreesfuerzo, ocurridas en jornada en centro para empresas manufactureras y de la construcción. Se calculó el riesgo relativo ajustado por sexo, edad y tipo de contrato en cada una de las CC.AA. mediante la razón de LAT estandarizada, tomando como referencia las tasas de España, y estratificando según duración de la baja (menos de 16 días y más de 15 días. Resultados: El riesgo relativo ajustado de LAT según los diferentes tipos de accidentes analizados presenta una distribución heterogénea entre CC.AA. Murcia, Navarra, Baleares y País Vasco se encuentran generalmente entre las comunidades con riesgos más elevados, mientras que Castilla-León y Extremadura son las que tienen principalmente menores riesgos de sufrir una LAT. Conclusiones: La heterogeneidad en la incidencia de LAT entre CC.AA. persiste después de seleccionar una serie de formas de accidente específicas y ajustar por sexo, edad y tipo de contrato. Por ello sugerimos que, además de seguir analizando las condiciones de trabajo como explicación de esta heterogeneidad, se tengan en cuenta otras variables socioeconómicas al comparar las incidencias de LAT entre CC.AA.Objectives: Given the differences observed in previous studies with respect to occupational injury rates in Spain's autonomous communities, this study tested the homogeneity hypothesis of occupational injury for specific accident types and economic activity between 1994 and 2004. Methods: We analyzed non-fatal injuries of a mechanical nature or those due to overexertion taking place in

  4. Unequal Exposure or Unequal Vulnerability? Contributions of Neighborhood Conditions and Cardiovascular Risk Factors to Socioeconomic Inequality in Incident Cardiovascular Disease in the Multi-Ethnic Study of Atherosclerosis.

    Science.gov (United States)

    Hussein, Mustafa; Diez Roux, Ana V; Mujahid, Mahasin S; Hastert, Theresa A; Kershaw, Kiarri N; Bertoni, Alain G; Baylin, Ana

    2017-11-23

    Risk factors can drive socioeconomic inequalities in cardiovascular disease (CVD) through differential exposure and differential vulnerability. We show how econometric decomposition directly enables simultaneous, policy-oriented assessment of these two mechanisms. We specifically estimated contributions via these mechanisms of neighborhood environment and proximal risk factors to socioeconomic inequality in CVD incidence. We followed 5,608 participants in the Multi-Ethnic Study of Atherosclerosis (2000-2012) until the first CVD event (median follow-up 12.2 years). We used a summary measure of baseline socioeconomic position (SEP). Covariates included baseline demographics, neighborhood, psychosocial, behavioral, and biomedical risk factors. Using Poisson models, we decomposed the difference (inequality) in incidence rates between low- and high-SEP groups into contributions of 1) differences in covariate means (differential exposure), and 2) differences in CVD risk associated with covariates (differential vulnerability). Notwithstanding large uncertainty in neighborhood estimates, our analysis suggests that differential exposure to poorer neighborhood socioeconomic conditions, adverse social environment, diabetes, and hypertension accounts for most of inequality. Psychosocial and behavioral contributions were negligible. Further, neighborhood SEP, female gender, and White race were more strongly associated with CVD among low-SEP (vs. high-SEP) participants. These differentials in vulnerability also accounted for nontrivial portions of the inequality, and could have important implications for intervention. © The Author(s) 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Cardiovascular Disease Population Risk Tool (CVDPoRT): predictive algorithm for assessing CVD risk in the community setting. A study protocol.

    Science.gov (United States)

    Taljaard, Monica; Tuna, Meltem; Bennett, Carol; Perez, Richard; Rosella, Laura; Tu, Jack V; Sanmartin, Claudia; Hennessy, Deirdre; Tanuseputro, Peter; Lebenbaum, Michael; Manuel, Douglas G

    2014-10-23

    Recent publications have called for substantial improvements in the design, conduct, analysis and reporting of prediction models. Publication of study protocols, with prespecification of key aspects of the analysis plan, can help to improve transparency, increase quality and protect against increased type I error. Valid population-based risk algorithms are essential for population health planning and policy decision-making. The purpose of this study is to develop, evaluate and apply cardiovascular disease (CVD) risk algorithms for the population setting. The Ontario sample of the Canadian Community Health Survey (2001, 2003, 2005; 77,251 respondents) will be used to assess risk factors focusing on health behaviours (physical activity, diet, smoking and alcohol use). Incident CVD outcomes will be assessed through linkage to administrative healthcare databases (619,886 person-years of follow-up until 31 December 2011). Sociodemographic factors (age, sex, immigrant status, education) and mediating factors such as presence of diabetes and hypertension will be included as predictors. Algorithms will be developed using competing risks survival analysis. The analysis plan adheres to published recommendations for the development of valid prediction models to limit the risk of overfitting and improve the quality of predictions. Key considerations are fully prespecifying the predictor variables; appropriate handling of missing data; use of flexible functions for continuous predictors; and avoiding data-driven variable selection procedures. The 2007 and 2009 surveys (approximately 50,000 respondents) will be used for validation. Calibration will be assessed overall and in predefined subgroups of importance to clinicians and policymakers. This study has been approved by the Ottawa Health Science Network Research Ethics Board. The findings will be disseminated through professional and scientific conferences, and in peer-reviewed journals. The algorithm will be accessible

  6. Fabrication of cerium-doped yttrium aluminum garnet thin films by a mist CVD method

    Energy Technology Data Exchange (ETDEWEB)

    Murai, Shunsuke, E-mail: murai@dipole7.kuic.kyoto-u.ac.jp; Sato, Takafumi; Yao, Situ; Kamakura, Ryosuke; Fujita, Koji; Tanaka, Katsuhisa

    2016-02-15

    We synthesized thin films, consisting of yttrium aluminum garnet doped with Ce{sup 3+} (YAG:Ce), using the mist chemical vapor deposition (CVD) method, which allows the fabrication of high-quality thin films under atmospheric conditions without the use of vacuum equipment. Under a deposition rate of approximately 1 μm/h, the obtained thin films had a typical thickness of 2 μm. The XRD analysis indicated that the thin films consisted of single-phase YAG:Ce. The Rutherford backscattering confirmed the stoichiometry; the composition of the film was determined to be (Y, Ce){sub 3}Al{sub 5}O{sub 12}, with a Ce content of Ce/(Y+Ce)=2.5%. The YAG:Ce thin films exhibited fluorescence due to the 5d–4f electronic transitions characteristic of the Ce ions occupying the eight-coordinated dodecahedral sites in the YAG lattice. - Highlights: • We have synthesized thin films of yttrium aluminum garnet doped with Ce{sup 3+} (YAG:Ce) by using a mist chemical vapor deposition (CVD) method for the first time. • The thickness of the single-phase and stoichiometric thin film obtained by 2 h deposition and following heat treatments is 2 μm. • The thin film is porous but optically transparent, and shows yellow fluorescence upon irradiation with a blue light. • Mist-CVD is a green and sustainable technique that allows fabrication of high-quality thin films at atmospheric conditions without vacuum equipment.

  7. Synthesis of graphene on nickel films by CVD method using methane

    International Nuclear Information System (INIS)

    Castro, Manuela O. de; Liebold-Ribeiro, Yvonne; Barros, Eduardo B.; Salomao, Francisco C.C.; Mendes Filho, Josue; Souza Filho, Antonio G.; Chesman, Carlos

    2011-01-01

    Full text: Nanomaterials have opened up many possibilities for groundbreaking innovations in various technologies of modern society. One key example is graphene, which is composed of one-atom-thick sheet of sp2-bonded carbon atoms, arranged in a hexagonal symmetry. However, real world applications of graphene require well-established and large synthesis techniques. The so-called Chemical Vapor Deposition (CVD) is one of the most promising method for synthesizing graphene. The general idea of this technique is to dissolve carbon atoms inside a transition metal melt at a certain temperature, then allowing the dissolved carbon to precipitate at lower temperatures as single layer graphene (SLG). In the present work, we used the CVD method and methane gas as carbon source for the synthesis of graphene on silicon (Si) substrates (300nm thermal oxide) covered with sputtered nickel (Ni) films as catalyst. In order to achieve large-area and defect-free graphene sheets the influence of the different growth parameters (growth temperature and time, gas flow of methane, film thickness and grain size of Ni) on quality and quantity of graphene growth were studied. The obtained graphene films were transferred to a silicon substrate by the polymer coating process, using polymethyl-methacrylate (PMMA) as coating. In order to characterize the transferred graphene we used Scanning Electron Microscopy (SEM), Raman Spectroscopy, Optical Microscopy and Atomic Force Microscopy (AFM). The results show the influence of CVD process parameters on the quality and quantity of graphene growth in our experimental conditions. Acknowledgments: The authors thank Brazilian agencies CNPq and FUNCAP for financial support and Alfonso Reina (MIT, USA) for helpful discussions. (author)

  8. Mediterranean Alcohol-Drinking Pattern and the Incidence of Cardiovascular Disease and Cardiovascular Mortality: The SUN Project

    Directory of Open Access Journals (Sweden)

    Aitor Hernandez-Hernandez

    2015-11-01

    Full Text Available Background: We assessed the still unclear effect of the overall alcohol-drinking pattern, beyond the amount of alcohol consumed, on the incidence of cardiovascular clinical disease (CVD. Methods: We followed 14,651 participants during up to 14 years. We built a score assessing simultaneously seven dimensions of alcohol consumption to capture the conformity to a traditional Mediterranean alcohol-drinking pattern (MADP. It positively scored moderate alcohol intake, alcohol intake spread out over the week, low spirit consumption, preference for wine, red wine consumption, wine consumed during meals and avoidance of binge drinking. Results: During 142,177 person-years of follow-up, 127 incident cases of CVD (myocardial infarction, stroke or cardiovascular mortality were identified. Compared with the category of better conformity with the MADP, the low-adherence group exhibited a non-significantly higher risk (HR of total CVD ((95% CI = 1.55 (0.58–4.16. This direct association with a departure from the traditional MADP was even stronger for cardiovascular mortality (HR (95% CI = 3.35 (0.77–14.5. Nevertheless, all these associations were statistically non-significant. Conclusion: Better conformity with the MADP seemed to be associated with lower cardiovascular risk in most point estimates; however, no significant results were found and more powered studies are needed to clarify the role of the MADP on CVD.

  9. Self-Reported Sleep Duration, Napping, and Incident Heart Failure: Prospective Associations in the British Regional Heart Study.

    Science.gov (United States)

    Wannamethee, S Goya; Papacosta, Olia; Lennon, Lucy; Whincup, Peter H

    2016-09-01

    To examine the associations between self-reported nighttime sleep duration and daytime sleep and incident heart failure (HF) in men with and without preexisting cardiovascular disease (CVD). Population-based prospective study. General practices in 24 British towns. Men aged 60-79 without prevalent HF followed for 9 years (N = 3,723). Information on incident HF cases was obtained from primary care records. Assessment of sleep was based on self-reported sleep duration at night and daytime napping. Self-reported short nighttime sleep duration and daytime sleep of longer than 1 hour were associated with preexisting CVD, breathlessness, depression, poor health, physical inactivity, and manual social class. In all men, self-reported daytime sleep of longer than 1 hour duration was associated with significantly greater risk of HF after adjustment for potential confounders (adjusted hazard ratio (aHR) = 1.69, 95% CI = 1.06-2.71) than in those who reported no daytime napping. Self-reported nighttime sleep duration was not associated with HF risk except in men with preexisting CVD (napping of longer than 1 hour is associated with greater risk of HF in older men. Self-reported short sleep (<6 hours) in men with CVD is associated with particularly high risk of developing HF. © 2016 The Authors. The Journal of the American Geriatrics Society published by Wiley Periodicals, Inc. on behalf of The American Geriatrics Society.

  10. Use of Kelvin probe force microscopy for identification of CVD grown graphene flakes on copper foil

    Science.gov (United States)

    Kumar, Rakesh; Mehta, B. R.; Kanjilal, D.

    2017-05-01

    Graphene flakes have been grown by chemical vapour deposition (CVD) method on Cu foils. The obtained graphene flakes have been characterized by optical microscopy, field emission scanning electron microscopy, Kelvin probe force microscopy (KPFM) and Raman spectroscopy. The graphene flakes grown on Cu foil comprise mainly single layer graphene and confirm that the nucleation for graphene growth starts very quickly. Moreover, KPFM has been found to be a valuable technique to differentiate between covered and uncovered portion of Cu foil by graphene flakes deposited for shorter duration. The results show that KPFM can be a very useful technique in understanding the mechanism of graphene growth.

  11. Ballistic Transport Exceeding 28 μm in CVD Grown Graphene.

    Science.gov (United States)

    Banszerus, Luca; Schmitz, Michael; Engels, Stephan; Goldsche, Matthias; Watanabe, Kenji; Taniguchi, Takashi; Beschoten, Bernd; Stampfer, Christoph

    2016-02-10

    We report on ballistic transport over more than 28 μm in graphene grown by chemical vapor deposition (CVD) that is fully encapsulated in hexagonal boron nitride. The structures are fabricated by an advanced dry van-der-Waals transfer method and exhibit carrier mobilities of up to three million cm(2)/(Vs). The ballistic nature of charge transport is probed by measuring the bend resistance in cross- and square-shaped devices. Temperature-dependent measurements furthermore prove that ballistic transport is maintained exceeding 1 μm up to 200 K.

  12. Role of biomarkers in predicting CVD risk in the setting of HIV infection?

    DEFF Research Database (Denmark)

    Worm, Signe W; Hsue, Priscilla

    2010-01-01

    with risk of CVD. Biomarkers associated with inflammation such as C-reactive protein and interleukin-6 have been suggested to improve risk stratification among intermediate-risk persons; however, their routine use is not recommended in the general population. Both biomarkers have recently been reported......-infected population and will increase as this population continues to age. Identification of intermediate-risk individuals using biomarkers will be an important tool for clinicians in the future to be able to treat HIV-infected individuals aggressively. Future studies of biomarkers among individuals with HIV...

  13. Fabrication and characteristics of self-assembly nano-polystyrene films by laser induced CVD

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Tingting [Department of Applied Physics, Chongqing University, Chongqing 401331 (China); Science and Technology on Plasma Physics Laboratory, Research Center of Laser Fusion, CAEP, Mianyang 621900 (China); Cai, Congzhong [Department of Applied Physics, Chongqing University, Chongqing 401331 (China); Peng, Liping [Science and Technology on Plasma Physics Laboratory, Research Center of Laser Fusion, CAEP, Mianyang 621900 (China); Wu, Weidong, E-mail: wuweidongding@163.com [Science and Technology on Plasma Physics Laboratory, Research Center of Laser Fusion, CAEP, Mianyang 621900 (China)

    2013-10-01

    The self-assembly nano-polystyrene (PS) films have been prepared by laser induced CVD at room temperature. The XPS, Raman and UV–vis absorption spectra all indicated that the films were PS. The optical properties, microstructure and controllable nanostructure of PS films have been investigated. Dewetting-like microstructure in PS films was investigated and uniform island structures with a diameter of about 200 nm were observed at the deposition pressure of 14 Pa. The films possess good toughness and precisely controlled thicknesses. The free-standing PS films with thickness of 10 nm could be obtained by this method though a series of process.

  14. Ethylene Gas Sensing Properties of Tin Oxide Nanowires Synthesized via CVD Method

    Science.gov (United States)

    Akhir, Maisara A. M.; Mohamed, Khairudin; Rezan, Sheikh A.; Arafat, M. M.; Haseeb, A. S. M. A.; Uda, M. N. A.; Nuradibah, M. A.

    2018-03-01

    This paper studies ethylene gas sensing performance of tin oxide (SnO2) nanowires (NWs) as sensing material synthesized using chemical vapor deposition (CVD) technique. The effect of NWs diameter on ethylene gas sensing characteristics were investigated. SnO2 NWs with diameter of ∼40 and ∼240 nm were deposited onto the alumina substrate with printed gold electrodes and tested for sensing characteristic toward ethylene gas. From the finding, the smallest diameter of NWs (42 nm) exhibit fast response and recovery time and higher sensitivity compared to largest diameter of NWs (∼240 nm). Both sensor show good reversibility features for ethylene gas sensor.

  15. Optical characterization of a-Si:H thin films grown by Hg-Photo-CVD

    International Nuclear Information System (INIS)

    Barhdadi, A.; Karbal, S.; M'Gafad, N.; Benmakhlouf, A.; Chafik El Idrissi, M.; Aka, B.M.

    2006-08-01

    Mercury-Sensitized Photo-Assisted Chemical Vapor Deposition (Hg-Photo-CVD) technique opens new possibilities for reducing thin film growth temperature and producing novel semiconductor materials suitable for the future generation of high efficiency thin film solar cells onto low cost flexible plastic substrates. This paper provides some experimental data resulting from the optical characterization of hydrogenated amorphous silicon thin films grown by this deposition technique. Experiments have been performed on both as-deposited layers and thermal annealed ones. (author) [fr

  16. Effect of pretreatment and deposition parameters on diamond nucleation in CVD

    International Nuclear Information System (INIS)

    Nazim, E.; Izman, S.; Ourdjini, A.; Shaharoun, A.M.

    2007-01-01

    Chemical vapour deposition (CVD) of diamond films on cemented carbide (WC) has aroused great interest in recent years. The combination of toughness from the WC and the high hardness of diamond results in outstanding wear resistance. This will increase the lifetime and better technical performance of the components made of diamond coated carbide. One of the important steps in the growth of diamond film is the nucleation of diamond as its density strongly influences the diamond growth process, film quality and morphology. In this paper the various effects of surface pretreatment and diamond deposition conditions on the diamond nucleation density are reviewed. (author)

  17. A Review of Carbon Nanomaterials’ Synthesis via the Chemical Vapor Deposition (CVD Method

    Directory of Open Access Journals (Sweden)

    Yehia M. Manawi

    2018-05-01

    Full Text Available Carbon nanomaterials have been extensively used in many applications owing to their unique thermal, electrical and mechanical properties. One of the prime challenges is the production of these nanomaterials on a large scale. This review paper summarizes the synthesis of various carbon nanomaterials via the chemical vapor deposition (CVD method. These carbon nanomaterials include fullerenes, carbon nanotubes (CNTs, carbon nanofibers (CNFs, graphene, carbide-derived carbon (CDC, carbon nano-onion (CNO and MXenes. Furthermore, current challenges in the synthesis and application of these nanomaterials are highlighted with suggested areas for future research.

  18. A Review of Carbon Nanomaterials’ Synthesis via the Chemical Vapor Deposition (CVD) Method

    Science.gov (United States)

    Manawi, Yehia M.; Samara, Ayman; Al-Ansari, Tareq; Atieh, Muataz A.

    2018-01-01

    Carbon nanomaterials have been extensively used in many applications owing to their unique thermal, electrical and mechanical properties. One of the prime challenges is the production of these nanomaterials on a large scale. This review paper summarizes the synthesis of various carbon nanomaterials via the chemical vapor deposition (CVD) method. These carbon nanomaterials include fullerenes, carbon nanotubes (CNTs), carbon nanofibers (CNFs), graphene, carbide-derived carbon (CDC), carbon nano-onion (CNO) and MXenes. Furthermore, current challenges in the synthesis and application of these nanomaterials are highlighted with suggested areas for future research. PMID:29772760

  19. The study on diamond-coated insert by DC plasma jet CVD

    International Nuclear Information System (INIS)

    Zhou Kesong; Dai Mingjiang; Song Jinbing; Kuang Tongchun; Liu Zhengyi

    2001-01-01

    Diamond coating were deposited on cemented carbide inserts by DC plasma jet CVD. The cemented carbide inserts were pretreated by methods including chemical etching of Co, Ar/H 2 plasma etching. The characteristics of diamond film, interface structure, adhesion strength and film stress were analysized by different methods such as SEM, XRD, Raman spectrum etc. A comparing experiment of cutting Al - 22 % Si alloy was carried out with diamond-coated cemented carbide inserts and uncoated cemented carbide inserts. The results show that the diamond-coated cemented carbide insert has a great advantage for cutting abrasive high content Al - Si alloy. (author)

  20. Growth, characterization and properties of CVD diamond films for applications as radiation detectors

    International Nuclear Information System (INIS)

    Sciorti, S.

    1999-01-01

    The aim of the work is to give a picture of the current state of the art of CVD (chemical vapour deposition) diamond. The interest is due to the capability to grow over large areas a material with physical properties suitable for an impressive number of applications. The authors focuses on the potential of diamond as a radiation detector and gets into details of the huge field that extends from the thermochemistry of the deposition process to the test of a diamond-based tracker with a fast readout electronics

  1. High-Resolution Energy and Intensity Measurements with CVD Diamond at REX-ISOLDE

    CERN Document Server

    Griesmayer, E; Dobos, D; Wenander, F; Bergoz, J; Bayle, H; Frais-Kölbl, H; Leinweber, J; Aumeyr, T; CERN. Geneva. BE Department

    2009-01-01

    A novel beam instrumentation device for the HIE-REX (High In-tensity and Energy REX) upgrade has been developed and tested at the On-Line Isotope Mass Separator ISOLDE, located at the European Laboratory for Particle Physics (CERN). This device is based on CVD diamond detector technology and is used for measuring the beam intensity, particle counting and measuring the energy spectrum of the beam. An energy resolution of 0.6% was measured at a carbon ion energy of 22.8 MeV. This corresponds to an energy spread of ± 140 keV.

  2. Joint association of physical activity/screen time and diet on CVD risk factors in 10-year-old children.

    Science.gov (United States)

    Drenowatz, Clemens; Carlson, Joseph J; Pfeiffer, Karin A; Eisenmann, Joey C

    2012-12-01

    The increasing prevalence of childhood overweight and obesity has been associated with an increased risk for cardiovascular disease (CVD). While several studies examined the effect of single behaviors such as physical activity (PA), sedentary behavior or diet on CVD risk, there is a lack of research on combined associations, specifically in children. Therefore, the purpose of this study was to examine the joint association of PA or screen time (ST) and diet on CVD risk factors in children. PA, STand diet were assessed via questionnaire in 210 fifth grade students (age: 10.6 ± 0.4 years). The healthy eating index (HEI) was subsequently calculated as indicator for diet quality. Height, weight, % body fat, and resting blood pressure were measured according to standard procedures and blood samples obtained via fingerprick were assayed for blood lipids. Total cholesterol HDL ratio (TC:HDL), mean arterial pressure (MAP), and % body fat were used as indicators of CVD risk. 55% of children did not meet current PA recommendations on at least 5 days/week and 70% exceeded current recommendations for ST. Further, only 2.5% possessed a "good" diet (HEI> 80). There was no significant association of PA or STand diet on CVD risk score. Neither TC:HDL, MAP, and % body fat nor the total CVD risk score was significantly correlated with diet, PA, or ST. Children in the high PA group, however, had significantly better diet scores. Despite the fact that self-reported PA, ST, or dietary intake were not directly related to CVD risk in this sample, higher activity levels were associated with a healthier diet and lower ST indicating an overall healthier lifestyle of this subgroup.

  3. Higher plasma soluble Receptor for Advanced Glycation End Products (sRAGE) levels are associated with incident cardiovascular disease and all-cause mortality in type 1 diabetes: a 12-year follow-up study

    DEFF Research Database (Denmark)

    Nin, Johanna W M; Jorsal, Anders; Merces Ferreira, Isabel Maria

    2010-01-01

    To investigate the associations of plasma levels of soluble receptor for advanced glycation end products (sRAGE) with incident cardiovascular disease (CVD) and all-cause mortality in type 1 diabetes and the extent to which any such associations could be explained by endothelial and renal dysfunct......To investigate the associations of plasma levels of soluble receptor for advanced glycation end products (sRAGE) with incident cardiovascular disease (CVD) and all-cause mortality in type 1 diabetes and the extent to which any such associations could be explained by endothelial and renal...

  4. VO{sub x} effectively doping CVD-graphene for transparent conductive films

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Qinghua; Shi, Liangjing [State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050 (China); Zhang, Qinghong [State Key Laboratory of Modification of Chemical Fibers and Polymer Materials, College of Material Science and Engineering, Donghua University, 2999 North Renmin Road, Shanghai 201620 (China); Wang, Weiqi; Zheng, Huifeng [State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050 (China); Zhang, Yuzhi [The Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, Chinese Academy of Sciences,1295 Dingxi Road, Shanghai 200050 (China); Liu, Yangqiao, E-mail: yqliu@mail.sic.ac.cn [State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050 (China); Sun, Jing, E-mail: jingsun@mail.sic.ac.cn [State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050 (China)

    2016-11-30

    Highlights: • Doping process operated easily. • Sheet resistance decreased efficiently after doping. • Sheet resistance of doped graphene is stable after exposed in the air. • Mechanism of doping process is studied. - Abstract: Chemical vapor deposition(CVD)-synthesized graphene is potentially an alternative for tin-doped indium oxide (ITO) transparent conductive films (TCFs), however its sheet resistance is still too high to meet many demands. Vanadium oxide has been widely applied as smart window materials, however, no study has been reported to use it as dopant to improve the conductivity of graphene TCFs. In this study, we firstly reported that VO{sub x} doping can effectively lower the sheet resistance of CVD-graphene films while keeping its good optical properties, whose transmittance is as high as 86–90%. The optimized VO{sub x}-doped graphene exhibits a sheet resistance as low as 176 Ω/□, which decreases by 56% compared to the undoped graphene films. The doping process is convenient, stable, economical and easy to operate. What is more, VO{sub x} can effectively increase the work function(WF) of the film, making it more appropriate for use in solar cells. The evolution of the VO{sub x} species annealed at different temperatures below 400 °C has been detailed studied for the first time, based on which the doping mechanism is proposed. The prepared VO{sub x} doped graphene is expected to be a promising candidate for transparent conductive film purposes.

  5. A novel Mo-W interlayer approach for CVD diamond deposition on steel

    Energy Technology Data Exchange (ETDEWEB)

    Kundrát, Vojtěch; Sullivan, John; Ye, Haitao, E-mail: h.ye@aston.ac.uk [School of Engineering and Applied Science, Aston University, Birmingham, B4 7ET (United Kingdom); Zhang, Xiaoling; Cooke, Kevin; Sun, Hailin [Miba Coating Group: Teer Coatings Ltd, West-Stone-House, West-Stone, Berry-Hill-Industrial-Estate, WR9 9AS, Droitwich (United Kingdom)

    2015-04-15

    Steel is the most widely used material in engineering for its cost/performance ratio and coatings are routinely applied on its surface to further improve its properties. Diamond coated steel parts are an option for many demanding industrial applications through prolonging the lifetime of steel parts, enhancement of tool performance as well as the reduction of wear rates. Direct deposition of diamond on steel using conventional chemical vapour deposition (CVD) processes is known to give poor results due to the preferential formation of amorphous carbon on iron, nickel and other elements as well as stresses induced from the significant difference in the thermal expansion coefficients of those materials. This article reports a novel approach of deposition of nanocrystalline diamond coatings on high-speed steel (M42) substrates using a multi-structured molybdenum (Mo) – tungsten (W) interlayer to form steel/Mo/Mo-W/W/diamond sandwich structures which overcome the adhesion problem related to direct magnetron sputtering deposition of pure tungsten. Surface, interface and tribology properties were evaluated to understand the role of such an interlayer structure. The multi-structured Mo-W interlayer has been proven to improve the adhesion between diamond films and steel substrates by acting as an effective diffusion barrier during the CVD diamond deposition.

  6. Controlled growth of CNT in mesoporous AAO through optimized conditions for membrane preparation and CVD operation

    Energy Technology Data Exchange (ETDEWEB)

    Ciambelli, P; Sarno, M; Leone, C; Sannino, D [Department of Chemical and Food Engineering, University of Salerno, I-84084 Fisciano (Italy); Arurault, L; Fontorbes, S; Datas, L; Lenormand, P; Le Blond Du Plouy, S, E-mail: msarno@unisa.it, E-mail: arurault@chimie.ups-tlse.fr [Universite de Toulouse, CIRIMAT, UPS/INPT/CNRS, LCMIE, F-31062 Toulouse Cedex 9 (France)

    2011-07-01

    Anodic aluminium oxide (RAAO) membranes with a mesoporous structure were prepared under strictly controlling experimental process conditions, and physically and chemically characterized by a wide range of experimental techniques. Commercial anodic aluminium oxide (CAAO) membranes were also investigated for comparison. We demonstrated that RAAO membranes have lower content of both water and phosphorus and showed better porosity shape than CAAO. The RAAO membranes were used for template growth of carbon nanotubes (CNT) inside its pores by ethylene chemical vapour deposition (CVD) in the absence of a catalyst. A composite material, containing one nanotube for each channel, having the same length as the membrane thickness and an external diameter close to the diameter of the membrane holes, was obtained. Yield, selectivity and quality of CNTs in terms of diameter, length and arrangement (i.e. number of tubes for each channel) were optimized by investigating the effect of changing the experimental conditions for the CVD process. We showed that upon thermal treatment RAAO membranes were made up of crystallized allotropic alumina phases, which govern the subsequent CNT growth, because of their catalytic activity, likely due to their Lewis acidity. The strict control of experimental conditions for membrane preparation and CNT growth allowed us to enhance the carbon structural order, which is a critical requisite for CNT application as a substitute for copper in novel nano-interconnects.

  7. GaN CVD Reactions: Hydrogen and Ammonia Decomposition and the Desorption of Gallium

    International Nuclear Information System (INIS)

    Bartram, Michael E.; Creighton, J. Randall

    1999-01-01

    Isotopic labeling experiments have revealed correlations between hydrogen reactions, Ga desorption, and ammonia decomposition in GaN CVD. Low energy electron diffraction (LEED) and temperature programmed desorption (TPD) were used to demonstrate that hydrogen atoms are available on the surface for reaction after exposing GaN(0001) to deuterium at elevated temperatures. Hydrogen reactions also lowered the temperature for Ga desorption significantly. Ammonia did not decompose on the surface before hydrogen exposure. However, after hydrogen reactions altered the surface, N 15 H 3 did undergo both reversible and irreversible decomposition. This also resulted in the desorption of N 2 of mixed isotopes below the onset of GaN sublimation, This suggests that the driving force of the high nitrogen-nitrogen bond strength (226 kcal/mol) can lead to the removal of nitrogen from the substrate when the surface is nitrogen rich. Overall, these findings indicate that hydrogen can influence G-aN CVD significantly, being a common factor in the reactivity of the surface, the desorption of Ga, and the decomposition of ammonia

  8. CVD growth of graphene under exfoliated hexagonal boron nitride for vertical hybrid structures

    International Nuclear Information System (INIS)

    Wang, Min; Jang, Sung Kyu; Song, Young Jae; Lee, Sungjoo

    2015-01-01

    Graphical abstract: We have demonstrated a novel yet simple method for fabricating graphene-based vertical hybrid structures by performing the CVD growth of graphene at an h-BN/Cu interface. Our systematic Raman measurements combined with plasma etching process indicate that a graphene film is grown under exfoliated h-BN rather than on its top surface, and that an h-BN/graphene vertical hybrid structure has been fabricated. Electrical transport measurements of this h-BN/graphene, transferred on SiO2, show the carrier mobility up to approximately 2250 cm 2 V −1 s −1 . The developed method would enable the exploration of the possibility of novel hybrid structure integration with two-dimensional material systems. - Abstract: We have demonstrated a novel yet simple method for fabricating graphene-based vertical hybrid structures by performing the CVD growth of graphene at an h-BN/Cu interface. Our systematic Raman measurements combined with plasma etching process indicate that a graphene film is grown under exfoliated h-BN rather than on its top surface, and that an h-BN/graphene vertical hybrid structure has been fabricated. Electrical transport measurements of this h-BN/graphene, transferred on SiO 2 , show the carrier mobility up to approximately 2250 cm 2 V −1 s −1 . The developed method would enable the exploration of the possibility of novel hybrid structure integration with two-dimensional material systems

  9. CVD tungsten metallization and electron beam lithography for fabricating submicron interconnects for advanced ULSI

    International Nuclear Information System (INIS)

    Wilson, S.R.; Mattox, R.J.

    1988-01-01

    CVD W (0.45μm thick) and CVD W (0.25μm thick) strapped by Al (0.5μm thick) have been used as metal 1 systems. Electrical and physical data are presented from experiments exploring the effects of processing issues with both e-beam and stepper lithography as well as dry etch chemistry on both metal systems. The special issues encountered with the thick tungsten processing were: (i) Significant e-beam proximity related problems as compared to the sandwich metal layers. The resultant e-beam proximity problem contributed to a high level of metal bridging and poor CD control. (ii) Multiple etch related problems due to mask failure and a lack of etch selectivity. The multilevel masks utilized, consisting of photoresist and plasma enhanced oxide (PEO), failed due to the poor etch selectivity. Poor etch selectivity with respect to the underlying oxide was also observed. These issues were addressed with thicker organic and PEO mask layers as well as changes in etch chemistry. These thick layers were successful in preventing the loss of the mask during etch., but caused problems in the e-beam CD control and did not prevent the degradation of the underlying glass. A higher selectivity etch was developed which greatly reduced the underlying dielectric damage and also allowed the use of the thinner organic and PEO hardmask layers without mask failure

  10. A novel Mo-W interlayer approach for CVD diamond deposition on steel

    Science.gov (United States)

    Kundrát, Vojtěch; Zhang, Xiaoling; Cooke, Kevin; Sun, Hailin; Sullivan, John; Ye, Haitao

    2015-04-01

    Steel is the most widely used material in engineering for its cost/performance ratio and coatings are routinely applied on its surface to further improve its properties. Diamond coated steel parts are an option for many demanding industrial applications through prolonging the lifetime of steel parts, enhancement of tool performance as well as the reduction of wear rates. Direct deposition of diamond on steel using conventional chemical vapour deposition (CVD) processes is known to give poor results due to the preferential formation of amorphous carbon on iron, nickel and other elements as well as stresses induced from the significant difference in the thermal expansion coefficients of those materials. This article reports a novel approach of deposition of nanocrystalline diamond coatings on high-speed steel (M42) substrates using a multi-structured molybdenum (Mo) - tungsten (W) interlayer to form steel/Mo/Mo-W/W/diamond sandwich structures which overcome the adhesion problem related to direct magnetron sputtering deposition of pure tungsten. Surface, interface and tribology properties were evaluated to understand the role of such an interlayer structure. The multi-structured Mo-W interlayer has been proven to improve the adhesion between diamond films and steel substrates by acting as an effective diffusion barrier during the CVD diamond deposition.

  11. Surface structure deduced differences of copper foil and film for graphene CVD growth

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Junjun [School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044 (China); Hu, Baoshan, E-mail: hubaoshan@cqu.edu.cn [School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044 (China); Wei, Zidong; Jin, Yan [School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044 (China); Luo, Zhengtang [Department of Chemical and Biomolecular Engineering, The Hongkong University of Science and Technology, Kowloon (Hong Kong); Xia, Meirong [School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044 (China); Pan, Qingjiang [Key Laboratory of Functional Inorganic Material Chemistry, Ministry of Education, Heilongjiang University, Harbin 150080 (China); Liu, Yunling [State Key Laboratory of Inorganic Synthesis and Preparative Chemistry, College of Chemistry, Jilin University, Changchun 130012 (China)

    2014-05-01

    Highlights: • We demonstrate the significant differences between Cu foil and film in the surface morphology and crystal orientation distribution. • The different surface structure leads to the distinctive influences of the CH₄ and H₂ concentrations on the thickness and quality of as-grown graphene. • Nucleation densities and growth rate differences at the initial growth stages on the Cu foil and film were investigated and discussed. Abstract: Graphene was synthesized on Cu foil and film by atmospheric pressure chemical vapor deposition (CVD) with CH₄ as carbon source. Electron backscattered scattering diffraction (EBSD) characterization demonstrates that the Cu foil surface after the H₂-assisted pre-annealing was almost composed of Cu(1 0 0) crystal facet with larger grain size of ~100 μm; meanwhile, the Cu film surface involved a variety of crystal facets of Cu(1 1 1), Cu(1 0 0), and Cu(1 1 0), with the relatively small grain size of ~10 μm. The different surface structure led to the distinctive influences of the CH₄ and H₂ concentrations on the thickness and quality of as-grown graphene. Further data demonstrate that the Cu foil enabled more nucleation densities and faster growth rates at the initial growth stages than the Cu film. Our results are beneficial for understanding the relationship between the metal surface structure and graphene CVD growth.

  12. Influence of tungsten on the carbon nanotubes growth by CVD process

    Energy Technology Data Exchange (ETDEWEB)

    Escobar, Mariano [Instituto de Fisicoquimica de Materiales, Ambiente y Energia, CONICET-UBA, Pabellon II, Ciudad Universitaria (1428) Bs As (Argentina); LP and MC, Dep. De Fisica, FCEyN-UBA, Pabellon 1, Ciudad Universitaria (1428) Bs As (Argentina)], E-mail: mescobar@qi.fcen.uba.ar; Rubiolo, Gerardo H. [LP and MC, Dep. De Fisica, FCEyN-UBA, Pabellon 1, Ciudad Universitaria (1428) Bs As (Argentina); Unidad de Actividad Materiales, CNEA, Av. Gral. Paz 1499, San Martin (1650), Bs As (Argentina); Moreno, M. Sergio [Centro Atomico Bariloche, (8400) S.C. de Bariloche, Rio Negro (Argentina); Goyanes, Silvia [LP and MC, Dep. De Fisica, FCEyN-UBA, Pabellon 1, Ciudad Universitaria (1428) Bs As (Argentina); Candal, Roberto [Instituto de Fisicoquimica de Materiales, Ambiente y Energia, CONICET-UBA, Pabellon II, Ciudad Universitaria (1428) Bs As (Argentina)

    2009-06-24

    The effect of tungsten (W) on the growth of multi-walled carbon nanotubes (MWNTs) using the chemical vapour deposition (CVD) process over a metal Fe-W catalyst incorporated into a silica matrix is reported. A W molar content in Fe/SiO{sub 2} up to 10% was studied. The incorporation of only 2% of W substantially modifies the crystalline phases and the crystalline degree of the catalyst during the MWNTs synthesis. This fact seems to have a strong influence on the type and yield of the carbonaceous species obtained by the CVD of acetylene, at 600 deg. C and 180 Torr, over each catalyst. Tungsten interacts with iron within the matrix, diminishing the catalytic activity of the metal nanoparticles, and both, carbon nanotubes and carbon nanofibers, are obtained when tungsten is present. The results obtained support the hypothesis of a base growth model for carbon nanotubes indicating a strong interaction between silica matrix and Fe/W nanoparticles, independently of the content of W.

  13. Influence of tungsten on the carbon nanotubes growth by CVD process

    International Nuclear Information System (INIS)

    Escobar, Mariano; Rubiolo, Gerardo H.; Moreno, M. Sergio; Goyanes, Silvia; Candal, Roberto

    2009-01-01

    The effect of tungsten (W) on the growth of multi-walled carbon nanotubes (MWNTs) using the chemical vapour deposition (CVD) process over a metal Fe-W catalyst incorporated into a silica matrix is reported. A W molar content in Fe/SiO 2 up to 10% was studied. The incorporation of only 2% of W substantially modifies the crystalline phases and the crystalline degree of the catalyst during the MWNTs synthesis. This fact seems to have a strong influence on the type and yield of the carbonaceous species obtained by the CVD of acetylene, at 600 deg. C and 180 Torr, over each catalyst. Tungsten interacts with iron within the matrix, diminishing the catalytic activity of the metal nanoparticles, and both, carbon nanotubes and carbon nanofibers, are obtained when tungsten is present. The results obtained support the hypothesis of a base growth model for carbon nanotubes indicating a strong interaction between silica matrix and Fe/W nanoparticles, independently of the content of W.

  14. Estimation of magnetic relaxation property for CVD processed YBCO-coated conductors

    International Nuclear Information System (INIS)

    Takahashi, Y.; Kiuchi, M.; Otabe, E.S.; Matsushita, T.; Shikimachi, K.; Watanabe, T.; Kashima, N.; Nagaya, S.

    2010-01-01

    Ion Beam Assist Deposition/Chemical Vapor Deposition(IBAD/CVD)-processed YBCO-coated conductors with high critical current density J c at high magnetic fields are expected to be applied to superconducting equipments such as superconducting magnetic energy storage (SMES). For application to superconducting magnet in SMES one of the most important properties for superconductors is the relaxation property of superconducting current. In this paper, the relaxation property is investigated for IBAD/CVD-processed YBCO-coated conductors of the superconducting layer in the range of 0.18-0.90 μm. This property can be quantitatively characterized by the apparent pinning potential, U 0 *. It is found that U 0 * takes a smaller value due to the two-dimensional pinning mechanism at high magnetic fields for conductor with thinner superconducting layer. Although U 0 * decreases with increasing thickness at low magnetic fields at 20 K, it increases at high magnetic fields. The results are theoretically explained by the model of the flux creep and flow based on the dimensionality of flux pinning. Scaling analysis is examined for the dependence of U 0 * on the magnetic field, temperature and the layer thickness.

  15. Low resistive edge contacts to CVD-grown graphene using a CMOS compatible metal

    Energy Technology Data Exchange (ETDEWEB)

    Shaygan, Mehrdad; Otto, Martin; Sagade, Abhay A.; Neumaier, Daniel [Advanced Microelectronic Center Aachen, AMO GmbH, Aachen (Germany); Chavarin, Carlos A. [Lehrstuhl Werkstoffe der Elektrotechnik, Duisburg-Essen Univ., Duisburg (Germany); Innovations for High Performance Microelectronics, IHP GmbH, Frankfurt (Oder) (Germany); Bacher, Gerd; Mertin, Wolfgang [Lehrstuhl Werkstoffe der Elektrotechnik, Duisburg-Essen Univ., Duisburg (Germany)

    2017-11-15

    The exploitation of the excellent intrinsic electronic properties of graphene for device applications is hampered by a large contact resistance between the metal and graphene. The formation of edge contacts rather than top contacts is one of the most promising solutions for realizing low ohmic contacts. In this paper the fabrication and characterization of edge contacts to large area CVD-grown monolayer graphene by means of optical lithography using CMOS compatible metals, i.e. Nickel and Aluminum is reported. Extraction of the contact resistance by Transfer Line Method (TLM) as well as the direct measurement using Kelvin Probe Force Microscopy demonstrates a very low width specific contact resistance down to 130 Ωμm. The contact resistance is found to be stable for annealing temperatures up to 150 C enabling further device processing. Using this contact scheme for edge contacts, a field effect transistor based on CVD graphene with a high transconductance of 0.63 mS/μm at 1 V bias voltage is fabricated. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. Stress in ion-implanted CVD Si3N4 films

    International Nuclear Information System (INIS)

    EerNisse, E.P.

    1977-01-01

    The compressive stress buildup caused in chemical-vapor-deposited (CVD) Si 3 N 4 films by ion implantation is shown to be caused entirely by atomic collision effects, ionization effects being unimportant. The stress introduction rate is shown to be independent of CVD processing variables and O content of the film. The maximum attainable compressive stress change is 3.5 x 10 10 dyn/cm 2 , resulting in a maximum net compressive stress of 2 x 10 10 dyn/cm 2 for films on Si where the as-deposited films inherently have 1.5 x 10 10 dyn/cm 2 tensile stress before ion implantation. Results are presented which show that O in the films inhibits thermal annealing of the ion-implantation-induced compressive stress. Results for introduction rate and annealing effects are presented in normalized form so that workers can use the effects for intentional stress level adjustment in the films to reduce probability of cracking and detachment

  17. Electrically insulating films deposited on V-4%Cr-4%Ti by reactive CVD

    International Nuclear Information System (INIS)

    Park, J.H.

    1998-04-01

    In the design of liquid-metal blankets for magnetic fusion reactors, corrosion resistance of structural materials and the magnetohydrodynamic forces and their influence on thermal hydraulics and corrosion are major concerns. Electrically insulating CaO films deposited on V-4%Cr-4%Ti exhibit high-ohmic insulator behavior even though a small amount of vanadium from the alloy become incorporated into the film. However, when vanadium concentration in the film is > 15 wt.%, the film becomes conductive. When the vanadium concentration is high in localized areas, a calcium vanadate phase that exhibits semiconductor behavior can form. The objective of this study is to evaluate electrically insulating films that were deposited on V-4%Cr-4%Ti by a reactive chemical vapor deposition (CVD) method. To this end, CaO and Ca-V-O coatings were produced on vanadium alloys by CVD and by a metallic-vapor process to investigate the electrical resistance of the coatings. The authors found that the Ca-V-O films exhibited insulator behavior when the ratio of calcium concentration to vanadium concentration R in the film > 0.9, and semiconductor or conductor behavior when R 0.98 were exposed in liquid lithium. Based on these studies, they conclude that semiconductor behavior occurs if a conductive calcium vanadate phase is present in localized regions in the CaO coating

  18. Parametric assessments on hydrogenic species transport in CVD-diamond vacuum windows used in ITER ECRH

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, C.; Sedano, L.A.; Fernandez, A. [EURATOM-CIEMAT Association, Madrid (Spain)

    2007-07-01

    Insulators used as H and CD and Diagnostic vacuum windows (VW) in ITER may become modified by surface intake and bulk transport of hydrogenic species. VW, operating under severe radiation levels, have a primary safety role as tritium confinement barriers. Ionizing radiation enhances the (H') uptake and release at surfaces and diffusion rates in the bulk. Radiation damage modifies the material's bulk trapped inventories by increasing steady state trapping centre concentrations. An experimental programme is ongoing at CIEMAT, to quantify radiation effects on H transport characteristics and also the possible impact on the VW. The reference material for ECRH VW is CVD diamond. As a parallel activity, parametric transport assessments are being made in order to obtain a wide evaluation of permeation fluxes, ranges, and soluted/trapped inventories in CVD diamond. Transport models have been developed based on extended capabilities of finite differences integrator tool TMAP7. Special attention is paid to radiation parameters defining inputs acting on transport magnitudes. These inputs have been analysed by using ionizing/damage radiation transport tools such as MCNPX/SRIM. VW operational scenarios are discussed with special attention being paid to the ITER design assumptions for the values of H-species source terms (neutrals and implanted) in the ECRH system. The available material transport database with and without radiation is discussed and taken as reference for this parametric exercise. Permeation fluxes through base materials are shown to be below DRG limits established for ITER. (orig.)

  19. A novel Mo-W interlayer approach for CVD diamond deposition on steel

    Directory of Open Access Journals (Sweden)

    Vojtěch Kundrát

    2015-04-01

    Full Text Available Steel is the most widely used material in engineering for its cost/performance ratio and coatings are routinely applied on its surface to further improve its properties. Diamond coated steel parts are an option for many demanding industrial applications through prolonging the lifetime of steel parts, enhancement of tool performance as well as the reduction of wear rates. Direct deposition of diamond on steel using conventional chemical vapour deposition (CVD processes is known to give poor results due to the preferential formation of amorphous carbon on iron, nickel and other elements as well as stresses induced from the significant difference in the thermal expansion coefficients of those materials. This article reports a novel approach of deposition of nanocrystalline diamond coatings on high-speed steel (M42 substrates using a multi-structured molybdenum (Mo – tungsten (W interlayer to form steel/Mo/Mo-W/W/diamond sandwich structures which overcome the adhesion problem related to direct magnetron sputtering deposition of pure tungsten. Surface, interface and tribology properties were evaluated to understand the role of such an interlayer structure. The multi-structured Mo-W interlayer has been proven to improve the adhesion between diamond films and steel substrates by acting as an effective diffusion barrier during the CVD diamond deposition.

  20. Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter

    International Nuclear Information System (INIS)

    Preciado-Flores, S.; Schreck, M.; Melendrez, R.; Chernov, V.; Bernal, R.; Cruz-Vazquez, C.; Cruz-Zaragoza, E.; Barboza-Flores, M.

    2006-01-01

    Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 μm thick CVD diamond (polycrystalline diamond films prepared by chemical vapor deposition) film were studied in order to test its performance as a beta radiation dosemeter. The TL response is composed of four main TL glow peaks; two of these are in the range of 150-200 deg. C and two additional peaks in the 250-400 deg. C temperature range. The integrated TL as a function of radiation dose is linear up to 100 Gy and increases with increasing dose exposure. The dose dependence of the integrated OSL exhibits a similar behavior. The observed OSL/TL behavior for the CVD diamond film clearly demonstrate its capability for applications in radiation dosimetry with special relevance in medical dosimetry owing to the diamond's intrinsic material properties. (authors)

  1. Performance of CVD and CVR coated carbon-carbon in high temperature hydrogen

    Science.gov (United States)

    Adams, J. W.; Barletta, R. E.; Svandrlik, J.; Vanier, P. E.

    As a part of the component development process for the particle bed reactor (PBR), it is necessary to develop coatings which will be time and temperature stable at extremely high temperatures in flowing hydrogen. These coatings must protect the underlying carbon structure from attack by the hydrogen coolant. Degradation which causes small changes in the reactor component, e.g. hole diameter in the hot frit, can have a profound effect on operation. The ability of a component to withstand repeated temperature cycles is also a coating development issue. Coatings which crack or spall under these conditions would be unacceptable. While refractory carbides appear to be the coating material of choice for carbon substrates being used in PBR components, the method of applying these coatings can have a large effect on their performance. Two deposition processes for these refractory carbides, chemical vapor deposition (CVD) and chemical vapor reaction (CVR), have been evaluated. Screening tests for these coatings consisted of testing of coated 2-D and 3-D weave carbon-carbon in flowing hot hydrogen at one atmosphere. Carbon loss from these samples was measured as a function of time. Exposure temperatures up to 3,000 K were used, and samples were exposed in a cyclical fashion cooling to room temperature between exposures. The results of these measurements are presented along with an evaluation of the relative merits of CVR and CVD coatings for this application.

  2. Influence of duration time of CVD process on emissive properties of carbon nanotubes films

    Directory of Open Access Journals (Sweden)

    Stępinska Izabela

    2015-03-01

    Full Text Available In this paper various types of films made of carbon nanotubes (CNTs are presented. These films were prepared on different substrates (Al2O3, Si n-type by the two-step method. The two-step method consists of physical vapor deposition step, followed by chemical vapor deposition step (PVD/CVD. Parameters of PVD process were the same for all initial films, while the duration times of the second step - the CVD process, were different (15, 30 min.. Prepared films were characterized by scanning electron microscopy (SEM, transmission electron microscopy (TEM and field emission (FE measurements. The I-E and F-N characteristics of electron emission were discussed in terms of various forms of CNT films. The value of threshold electric field ranged from few V/μm (for CNT dispersed rarely on the surface of the film deposited on Si up to ~20 V/μm (for Al2O3 substrate.

  3. Unravelling merging behaviors and electrostatic properties of CVD-grown monolayer MoS2 domains

    International Nuclear Information System (INIS)

    Hao, Song; Yang, Bingchu; Gao, Yongli

    2016-01-01

    The presence of grain boundaries is inevitable for chemical vapor deposition (CVD)-grown MoS 2 domains owing to various merging behaviors, which greatly limits its potential applications in novel electronic and optoelectronic devices. It is therefore of great significance to unravel the merging behaviors of the synthesized polygon shape MoS 2 domains. Here we provide systematic investigations of merging behaviors and electrostatic properties of CVD-grown polycrystalline MoS 2 crystals by multiple means. Morphological results exhibit various polygon shape features, ascribed to polycrystalline crystals merged with triangle shape MoS 2 single crystals. The thickness of triangle and polygon shape MoS 2 crystals is identical manifested by Raman intensity and peak position mappings. Three merging behaviors are proposed to illustrate the formation mechanisms of observed various polygon shaped MoS 2 crystals. The combined photoemission electron microscopy and kelvin probe force microscopy results reveal that the surface potential of perfect merged crystals is identical, which has an important implication for fabricating MoS 2 -based devices.

  4. Mindfulness-Based Interventions for Weight Loss and CVD Risk Management

    Science.gov (United States)

    Fulwiler, Carl; Brewer, Judson A.; Sinnott, Sinead; Loucks, Eric B.

    2017-01-01

    Obesity affects more than one-third of U.S. adults and is a major cause of preventable morbidity and mortality, primarily from cardiovascular disease. Traditional behavioral interventions for weight loss typically focus on diet and exercise habits and often give little attention to the role of stress and emotions in the initiation and maintenance of unhealthy behaviors, which may account for their modest results and considerable variability in outcomes. Stress eating and emotional eating are increasingly recognized as important targets of weight loss interventions. Mindfulness-based interventions were specifically developed to promote greater self-efficacy in coping with stress and negative emotions, and appear to be effective for a variety of conditions. In recent years researchers have begun to study mindfulness interventions for weight loss and CVD risk management. This review describes the rationale for the use of mindfulness in interventions for weight loss and CVD risk management, summarizes the research to date, and suggests priorities for future research. PMID:28405260

  5. Does productivity influence priority setting? A case study from the field of CVD prevention

    Directory of Open Access Journals (Sweden)

    Löfroth Emil

    2008-03-01

    Full Text Available Abstract In this case study, different measures aimed at preventing cardiovascular diseases (CVD in different target groups have been ranked based on cost per QALY from a health care sector perspective and from a societal perspective, respectively. The innovation in this study is to introduce a budget constraint and thereby show exactly which groups would be included or excluded in treatment or intervention programs based on the two perspectives. Approximately 90% of the groups are included in both perspectives. Mainly elderly women are excluded when the societal perspective is used and mainly middle-aged men are excluded when the health care sector perspective is used. Elderly women have a higher risk of CVD and generally lower income than middle-aged men. Thus the exclusion of older women in the societal perspective is not a trivial consequence since it is in conflict with the general interpretation of the "treatment according to need" rule, as well as societal goals regarding gender equality and fairness. On the other hand, the exclusion of working individuals in the health care perspective undermines a growth of public resources for future health care for the elderly. The extent and consequences of this conflict are unclear and empirical studies of this problem are rare.

  6. Electrical and thermal conductivity of low temperature CVD graphene: the effect of disorder

    International Nuclear Information System (INIS)

    Vlassiouk, Ivan; Datskos, Panos; Smirnov, Sergei; Ivanov, Ilia; Hensley, Dale; Lavrik, Nickolay V; Fulvio, Pasquale F; Dai Sheng; Meyer, Harry; Chi Miaofang

    2011-01-01

    In this paper we present a study of graphene produced by chemical vapor deposition (CVD) under different conditions with the main emphasis on correlating the thermal and electrical properties with the degree of disorder. Graphene grown by CVD on Cu and Ni catalysts demonstrates the increasing extent of disorder at low deposition temperatures as revealed by the Raman peak ratio, I G /I D . We relate this ratio to the characteristic domain size, L a , and investigate the electrical and thermal conductivity of graphene as a function of L a . The electrical resistivity, ρ, measured on graphene samples transferred onto SiO 2 /Si substrates shows linear correlation with L a -1 . The thermal conductivity, K, measured on the same graphene samples suspended on silicon pillars, on the other hand, appears to have a much weaker dependence on L a , close to K ∼ L a 1/3 . It results in an apparent ρ ∼ K 3 correlation between them. Despite the progressively increasing structural disorder in graphene grown at lower temperatures, it shows remarkably high thermal conductivity (10 2 -10 3 W K -1 m -1 ) and low electrical (10 3 -3 x 10 5 Ω) resistivities suitable for various applications.

  7. Optical characterization of single-crystal diamond grown by DC arc plasma jet CVD

    Science.gov (United States)

    Hei, Li-fu; Zhao, Yun; Wei, Jun-jun; Liu, Jin-long; Li, Cheng-ming; Lü, Fan-xiu

    2017-12-01

    Optical centers of single-crystal diamond grown by DC arc plasma jet chemical vapor deposition (CVD) were examined using a low-temperature photoluminescence (PL) technique. The results show that most of the nitrogen-vacancy (NV) complexes are present as NV- centers, although some H2 and H3 centers and B-aggregates are also present in the single-crystal diamond because of nitrogen aggregation resulting from high N2 incorporation and the high mobility of vacancies under growth temperatures of 950-1000°C. Furthermore, emissions of radiation-induced defects were also detected at 389, 467.5, 550, and 588.6 nm in the PL spectra. The reason for the formation of these radiation-induced defects is not clear. Although a Ni-based alloy was used during the diamond growth, Ni-related emissions were not detected in the PL spectra. In addition, the silicon-vacancy (Si-V)-related emission line at 737 nm, which has been observed in the spectra of many previously reported microwave plasma chemical vapor deposition (MPCVD) synthetic diamonds, was absent in the PL spectra of the single-crystal diamond prepared in this work. The high density of NV- centers, along with the absence of Ni-related defects and Si-V centers, makes the single-crystal diamond grown by DC arc plasma jet CVD a promising material for applications in quantum computing.

  8. Heparin free coating on PLA membranes for enhanced hemocompatibility via iCVD

    Science.gov (United States)

    Wang, Hui; Shi, Xiao; Gao, Ailin; Lin, Haibo; Chen, Yongliang; Ye, Yumin; He, Jidong; Liu, Fu; Deng, Gang

    2018-03-01

    In the present work, we report one-step immobilization of nano-heparin coating on PLA membranes via initiated chemical vapor deposition (iCVD) for enhanced hemocompatibility. The nano-coating introduced onto the membrane surface via the crosslinking of P(MAA-EGDA) was confirmed by the FTIR, SEM and weight measurement respectively. The negative carboxyl groups could form the hydration interaction with the protein and platelets and electrostatic interaction with amide groups of thrombin by the mediation of antithrombin, which is similar but different with heparin. The P(MAA-EGDA) coated membranes showed suppressed platelet adhesion and prolonged clotting time (APTTs increased to 59 s, PTs increased to 20.4 s, TTs increased to 17.5 s, and the FIBs declined by 30 mg/dL). Moreover, the complement activation tests demonstrated the formation of C3a and C5a was inhibited. All results demonstrated that the nano-coating of P(MAA-EGDA) via iCVD significantly enhanced the hemocompatibility of PLA membranes, which is also applicable for various membranes.

  9. Sub-bandgap optical absorption spectroscopy of hydrogenated microcrystalline silicon thin films prepared using hot-wire CVD (Cat-CVD) process

    International Nuclear Information System (INIS)

    Goktas, O.; Isik, N.; Okur, S.; Gunes, M.; Carius, R.; Klomfass, J.; Finger, F.

    2006-01-01

    Hydrogenated microcrystalline silicon (μc-Si:H) thin films with different silane concentration (SC) have been prepared using the HW-CVD technique. Dual beam photoconductivity (DBP), photothermal deflection spectroscopy (PDS), and transmission measurements have been used to investigate the optical properties of the μc-Si:H films. Two different sub-bandgap absorption, α(hν), methods have been applied and analyzed to obtain a better insight into the electronic states involved. A good agreement has been obtained in the absorption spectrum obtained from the PDS and DBP measurements at energies above the bandgap. Differences between PDS and DBP spectra exist below the bandgap energy where DBP spectra always give lower α(hν) values and show a dependence on the SC. For some films, differences exist in the α(hν) spectra when the DBP measurements are carried out through the film and substrate side. In addition, for some films, there remains fringe pattern left on the spectrum after the calculation of the fringe-free absorption spectrum, which indicates structural inhomogeneities present throughout the film

  10. Synthesis of AlN fine particles by surface corona discharge-CVD; Enmen corona hoden CVD ni yoru AlN biryushi no gosei

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Y.; Chiba, S. [Hokkaido National Industrial Research Institute, Sapporo (Japan); Harima, K> ; Kondo, K.; Shinohara, K. [Hokkaido University, Sapporo (Japan)

    1994-09-15

    With an objective to improve insulating and heat dissipating substrates substituting for the conventional alumina substrates, discussions been given on synthesis of AlN fine particles by means of gaseous phase reaction between AlCl3 and NH3 using surface corona discharge as a reaction exciting source. AIN particles should be highly pure to acquire high-heat conductivity, and fine and uniform particles to obtain dense sinters at low temperatures. The particles obtained by using the present method were amorphous particles having nearly spherical form and smooth surface. The particle diameter depends on the initial concentration of AlCl3, and is proportional to 0.4 square of the concentration. Within the range in the present experiment, the diameters ranged from 208 nm to 431 nm. The particle diameter increased in proportion to 0.2 square of an average gas stagnating time within the plasma generating region. The particle size distribution consisted of highly uniform fine particles having the standard deviation at about the same degree as that in the conventional thermal CVD process. The alumina-based oxygen was removed completely by reduction due to graphite powder, but the re-oxidation during removal of the remaining graphite using combustion had oxygen remained at 7.4% by weight. 16 refs., 7 figs.

  11. Future prospect of remote Cat-CVD on the basis of the production, transportation and detection of H atoms

    International Nuclear Information System (INIS)

    Umemoto, Hironobu; Matsumura, Hideki

    2008-01-01

    The future prospect of remote Cat-CVD, in which the decomposition and the deposition chambers are separated, is discussed on the basis of the absolute density measurements of H atoms. It is now well recognized that uniform deposition is possible on a large area without plasma damages by Cat-CVD. However, we may not overlook the demerits in Cat-CVD. One of the demerits is the poisoning of the catalyzer surfaces by the material gases, both temporary and permanent. One technique to overcome this problem is remote Cat-CVD. The question is how to separate the decomposition and deposition areas. If the separation is not enough, there should be back diffusion of the material gases, which will poison the catalyzers. If the separation is too tight, radicals may not effuse out from the decomposition chamber. These problems are discussed and it is shown that SiO 2 coating to reduce the radical recombination rates on walls is promising. The possibility of the polytetrafluoroethene coating by Cat-CVD is also discussed

  12. Cancer incidence among waiters

    DEFF Research Database (Denmark)

    Reijula, Jere; Kjaerheim, Kristina; Lynge, Elsebeth

    2015-01-01

    AIMS: To study cancer risk patterns among waiters in the Nordic countries. METHODS: We identified a cohort of 16,134 male and 81,838 female waiters from Denmark, Finland, Iceland, Norway and Sweden. During the follow-up period from 1961 to 2005, we found that 19,388 incident cancer cases were...... diagnosed. Standardised incidence ratio (SIR) was defined as the observed number of cancer cases divided by the expected number, based on national age, time period and gender-specific cancer incidence rates in the general population. RESULTS: The SIR of all cancers in waiters, in the five countries combined...... INCIDENCE IN SOME CANCER SITES CAN LIKELY BE EXPLAINED BY HIGHER ALCOHOL CONSUMPTION, THE PREVALENCE OF SMOKING AND OCCUPATIONAL EXPOSURE TO TOBACCO SMOKE HOPEFULLY, THE INCIDENCE OF CANCER AMONG WAITERS WILL DECREASE IN THE FUTURE, DUE TO THE BANNING OF TOBACCO SMOKING IN RESTAURANTS AND BARS IN THE NORDIC...

  13. Radiological incidents in radiotherapy

    International Nuclear Information System (INIS)

    Hobzova, L.; Novotny, J.

    2008-01-01

    In many countries a reporting system of radiological incidents to national regulatory body exists and providers of radiotherapy treatment are obliged to report all major and/or in some countries all incidents occurring in institution. State Office for Nuclear Safety (SONS) is providing a systematic guidance for radiotherapy departments from 1997 by requiring inclusion of radiation safety problems into Quality assurance manual, which is the basic document for obtaining a license of SONS for handling with sources of ionizing radiation. For that purpose SONS also issued the recommendation 'Introduction of QA system for important sources in radiotherapy-radiological incidents' in which the radiological incidents are defined and the basic guidance for their classification (category A, B, C, D), investigation and reporting are given. At regular periods the SONS in co-operation with radiotherapy centers is making a survey of all radiological incidents occurring in institutions and it is presenting obtained information in synoptic communication (2003 Motolske dny, 2005 Novy Jicin). This presentation is another summary report of radiological incidents that occurred in our radiotherapy institutions during last 3 years. Emphasis is given not only to survey and statistics, but also to analysis of reasons of the radiological incidents and to their detection and prevention. Analyses of incidents in radiotherapy have led to a much broader understanding of incident causation. Information about the error should be shared as early as possible during or after investigation by all radiotherapy centers. Learning from incidents, errors and near misses should be a part of improvement of the QA system in institutions. Generally, it is recommended that all radiotherapy facilities should participate in the reporting, analyzing and learning system to facilitate the dissemination of knowledge throughout the whole country to prevent errors in radiotherapy.(authors)

  14. A comparative study of the thermoluminescent response to beta irradiation of CVD diamond and LiF dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Bogani, F. [Florence Univ. (Italy). Dipt. di Energetica; Borchi, E. [Florence Univ. (Italy). Dipt. di Energetica; Bruzzi, M. [Florence Univ. (Italy). Dipt. di Energetica; Leroy, C. [Florence Univ. (Italy). Dipt. di Energetica; Sciortino, S. [Florence Univ. (Italy). Dipt. di Energetica

    1997-04-01

    The thermoluminescent (TL) response of chemical vapour deposited (CVD) diamond films to beta irradiation has been investigated. A numerical curve-fitting procedure, calibrated by means of a set of LiF TLD100 experimental spectra, has been developed to deconvolute the complex structured TL glow curves. The values of the activation energy and of the frequency factor related to each of the TL peaks involved have been determined. The TL response of the CVD diamond films to beta irradiation has been compared with the TL response of a set of LiF TLD100 and TLD700 dosimeters. The results have been discussed and compared in view of an assessment of the efficiency of CVD diamond films in future applications as in vivo dosimeters. (orig.).

  15. A comparative study of the thermoluminescent response to beta irradiation of CVD diamond and LiF dosimeters

    Science.gov (United States)

    Bogani, F.; Borchi, E.; Bruzzi, M.; Leroy, C.; Sciortino, S.

    1997-02-01

    The thermoluminescent (TL) response of Chemical Vapour Deposited (CVD) diamond films to beta irradiation has been investigated. A numerical curve-fitting procedure, calibrated by means of a set of LiF TLD100 experimental spectra, has been developed to deconvolute the complex structured TL glow curves. The values of the activation energy and of the frequency factor related to each of the TL peaks involved have been determined. The TL response of the CVD diamond films to beta irradiation has been compared with the TL response of a set of LiF TLD100 and TLD700 dosimeters. The results have been discussed and compared in view of an assessment of the efficiency of CVD diamond films in future applications as in vivo dosimeters.

  16. A comparative study of the thermoluminescent response to beta irradiation of CVD diamond and LiF dosimeters

    International Nuclear Information System (INIS)

    Bogani, F.; Borchi, E.; Bruzzi, M.; Leroy, C.; Sciortino, S.

    1997-01-01

    The thermoluminescent (TL) response of chemical vapour deposited (CVD) diamond films to beta irradiation has been investigated. A numerical curve-fitting procedure, calibrated by means of a set of LiF TLD100 experimental spectra, has been developed to deconvolute the complex structured TL glow curves. The values of the activation energy and of the frequency factor related to each of the TL peaks involved have been determined. The TL response of the CVD diamond films to beta irradiation has been compared with the TL response of a set of LiF TLD100 and TLD700 dosimeters. The results have been discussed and compared in view of an assessment of the efficiency of CVD diamond films in future applications as in vivo dosimeters. (orig.)

  17. Prediction of the properties of PVD/CVD coatings with the use of FEM analysis

    International Nuclear Information System (INIS)

    Śliwa, Agata; Mikuła, Jarosław; Gołombek, Klaudiusz; Tański, Tomasz; Kwaśny, Waldemar; Bonek, Mirosław; Brytan, Zbigniew

    2016-01-01

    Highlights: • Prediction of the properties of PVD/CVD coatings with the use of (FEM) analysis. • Stress distribution in multilayer Ti/Ti(C,N)/CrN, Ti/Ti(C,N)/(Ti,Al)N coatings. • The experimental values of stresses were determined on X-ray diffraction patterns. • An FEM model was established for the purpose of building a computer simulation. - Abstract: The aim of this paper is to present the results of the prediction of the properties of PVD/CVD coatings with the use of finite element method (FEM) analysis. The possibility of employing the FEM in the evaluation of stress distribution in multilayer Ti/Ti(C,N)/CrN, Ti/Ti(C,N)/(Ti,Al)N, Ti/(Ti,Si)N/(Ti,Si)N, and Ti/DLC/DLC coatings by taking into account their deposition conditions on magnesium alloys has been discussed in the paper. The difference in internal stresses in the zone between the coating and the substrate is caused by, first of all, the difference between the mechanical and thermal properties of the substrate and the coating, and also by the structural changes that occur in these materials during the fabrication process, especially during the cooling process following PVD and CVD treatment. The experimental values of stresses were determined based on X-ray diffraction patterns that correspond to the modelled values, which in turn can be used to confirm the correctness of the accepted mathematical model for testing the problem. An FEM model was established for the purpose of building a computer simulation of the internal stresses in the coatings. The accuracy of the FEM model was verified by comparing the results of the computer simulation of the stresses with experimental results. A computer simulation of the stresses was carried out in the ANSYS environment using the FEM method. Structure observations, chemical composition measurements, and mechanical property characterisations of the investigated materials has been carried out to give a background for the discussion of the results that were

  18. Prediction of the properties of PVD/CVD coatings with the use of FEM analysis

    Energy Technology Data Exchange (ETDEWEB)

    Śliwa, Agata; Mikuła, Jarosław; Gołombek, Klaudiusz; Tański, Tomasz; Kwaśny, Waldemar; Bonek, Mirosław, E-mail: miroslaw.bonek@polsl.pl; Brytan, Zbigniew

    2016-12-01

    Highlights: • Prediction of the properties of PVD/CVD coatings with the use of (FEM) analysis. • Stress distribution in multilayer Ti/Ti(C,N)/CrN, Ti/Ti(C,N)/(Ti,Al)N coatings. • The experimental values of stresses were determined on X-ray diffraction patterns. • An FEM model was established for the purpose of building a computer simulation. - Abstract: The aim of this paper is to present the results of the prediction of the properties of PVD/CVD coatings with the use of finite element method (FEM) analysis. The possibility of employing the FEM in the evaluation of stress distribution in multilayer Ti/Ti(C,N)/CrN, Ti/Ti(C,N)/(Ti,Al)N, Ti/(Ti,Si)N/(Ti,Si)N, and Ti/DLC/DLC coatings by taking into account their deposition conditions on magnesium alloys has been discussed in the paper. The difference in internal stresses in the zone between the coating and the substrate is caused by, first of all, the difference between the mechanical and thermal properties of the substrate and the coating, and also by the structural changes that occur in these materials during the fabrication process, especially during the cooling process following PVD and CVD treatment. The experimental values of stresses were determined based on X-ray diffraction patterns that correspond to the modelled values, which in turn can be used to confirm the correctness of the accepted mathematical model for testing the problem. An FEM model was established for the purpose of building a computer simulation of the internal stresses in the coatings. The accuracy of the FEM model was verified by comparing the results of the computer simulation of the stresses with experimental results. A computer simulation of the stresses was carried out in the ANSYS environment using the FEM method. Structure observations, chemical composition measurements, and mechanical property characterisations of the investigated materials has been carried out to give a background for the discussion of the results that were

  19. Treatment with liraglutide may improve markers of CVD reflected by reduced levels of apoB

    Science.gov (United States)

    Engelbrechtsen, L.; Lundgren, J.; Wewer Albrechtsen, N. J.; Mahendran, Y.; Iepsen, E. W.; Finocchietto, P.; Jonsson, A. E.; Madsbad, S.; Holst, J. J.; Vestergaard, H.; Hansen, T.

    2017-01-01

    Summary Background Dislipidaemia and increased levels of apolipoprotein B (apoB) in individuals with obesity are risk factors for development of cardiovascular disease (CVD). The aim of this study was to investigate the effect of weight loss and weight maintenance with and without liraglutide treatment on plasma lipid profiles and apoB. Methods Fifty‐eight individuals with obesity (body mass index 34.5 ± 3.0 kg/m2 [mean ± SD]) were included in this study. After 8 weeks on a very low‐calorie diet (800 kcal/day), participants were randomized to weight maintenance with meal replacements with or without liraglutide (1.2 mg daily) for 1 year. Plasma samples from before and after weight loss and after 1 year of weight maintenance were subjected to nuclear magnetic resonance‐based lipidomics analysis. Results After an 8‐week low‐calorie diet, study participants lost 12.0 ± 2.9 kg (mean ± SD) of their body weight, which was reflected in their lipid profiles (80 out of 124 lipids changed significantly), including reduced levels of apoB, total cholesterol, free cholesterol, remnant cholesterol, triglycerides, low‐density lipoprotein and very low‐density lipoprotein subclasses. After 1 year of maintained weight loss, the majority of the lipids had returned to pre‐weight loss levels even though weight loss was successfully maintained in both groups. Interestingly, apoB levels remained low in the liraglutide treated group (apoB change: 0.03 ± 0.02 mmol/L, p = 0.4) in contrast to an increase in the control group (apoB change: 0.06 ± 0.07 mmol/L, p = 0.02). Conclusion An 8‐week low‐calorie diet, in individuals with obesity, reduced plasma levels of lipids and the atherogenic marker apoB. After 1 year of weight maintenance, only study participants treated with liraglutide maintained reduced levels of apoB, despite similar body weight maintenance. Treatment with liraglutide may therefore reduce apoB levels and thus reflect lower

  20. Treatment with liraglutide may improve markers of CVD reflected by reduced levels of apoB.

    Science.gov (United States)

    Engelbrechtsen, L; Lundgren, J; Wewer Albrechtsen, N J; Mahendran, Y; Iepsen, E W; Finocchietto, P; Jonsson, A E; Madsbad, S; Holst, J J; Vestergaard, H; Hansen, T; Torekov, S S

    2017-12-01

    Dislipidaemia and increased levels of apolipoprotein B (apoB) in individuals with obesity are risk factors for development of cardiovascular disease (CVD). The aim of this study was to investigate the effect of weight loss and weight maintenance with and without liraglutide treatment on plasma lipid profiles and apoB. Fifty-eight individuals with obesity (body mass index 34.5 ± 3.0 kg/m 2 [mean ± SD]) were included in this study. After 8 weeks on a very low-calorie diet (800 kcal/day), participants were randomized to weight maintenance with meal replacements with or without liraglutide (1.2 mg daily) for 1 year. Plasma samples from before and after weight loss and after 1 year of weight maintenance were subjected to nuclear magnetic resonance-based lipidomics analysis. After an 8-week low-calorie diet, study participants lost 12.0 ± 2.9 kg (mean ± SD) of their body weight, which was reflected in their lipid profiles (80 out of 124 lipids changed significantly), including reduced levels of apoB, total cholesterol, free cholesterol, remnant cholesterol, triglycerides, low-density lipoprotein and very low-density lipoprotein subclasses. After 1 year of maintained weight loss, the majority of the lipids had returned to pre-weight loss levels even though weight loss was successfully maintained in both groups. Interestingly, apoB levels remained low in the liraglutide treated group (apoB change: 0.03 ± 0.02 mmol/L, p = 0.4) in contrast to an increase in the control group (apoB change: 0.06 ± 0.07 mmol/L, p = 0.02). An 8-week low-calorie diet, in individuals with obesity, reduced plasma levels of lipids and the atherogenic marker apoB. After 1 year of weight maintenance, only study participants treated with liraglutide maintained reduced levels of apoB, despite similar body weight maintenance. Treatment with liraglutide may therefore reduce apoB levels and thus reflect lower CVD risk. Including apoB measurements in clinical practice when

  1. Traffic-related air pollution exposure and incidence of stroke in four cohorts from Stockholm.

    Science.gov (United States)

    Korek, Michal J; Bellander, Tom D; Lind, Tomas; Bottai, Matteo; Eneroth, Kristina M; Caracciolo, Barbara; de Faire, Ulf H; Fratiglioni, Laura; Hilding, Agneta; Leander, Karin; Magnusson, Patrik K E; Pedersen, Nancy L; Östenson, Claes-Göran; Pershagen, Göran; Penell, Johanna C

    2015-01-01

    We investigated the risk of stroke related to long-term ambient air pollution exposure, in particular the role of various exposure time windows, using four cohorts from Stockholm County, Sweden. In total, 22,587 individuals were recruited from 1992 to 2004 and followed until 2011. Yearly air pollution levels resulting from local road traffic emissions were assessed at participant residences using dispersion models for particulate matter (PM10) and nitrogen oxides (NOX). Cohort-specific hazard ratios were estimated for time-weighted air pollution exposure during different time windows and the incidence of stroke, adjusted for common risk factors, and then meta-analysed. Overall, 868 subjects suffered a non-fatal or fatal stroke during 238,731 person-years of follow-up. An increment of 20 μg/m(3) in estimated annual mean of road-traffic related NOX exposure at recruitment was associated with a hazard ratio of 1.16 (95% CI 0.83-1.61), with evidence of heterogeneity between the cohorts. For PM10, an increment of 10 μg/m(3) corresponded to a hazard ratio of 1.14 (95% CI 0.68-1.90). Time-window analyses did not reveal any clear induction-latency pattern. In conclusion, we found suggestive evidence of an association between long-term exposure to NOX and PM10 from local traffic and stroke at comparatively low levels of air pollution.

  2. Influence of CVD diamond tips and Er:YAG laser irradiation on bonding of different adhesive systems to dentin

    OpenAIRE

    da Silva, Melissa Aline [UNESP; Nicolo, Rebeca Di [UNESP; Barcellos, Daphne Camara [UNESP; Batista, Graziela Ribeiro [UNESP; Pucci, Cesar Rogerio [UNESP; Torres, Carlos Rocha Gomes [UNESP; Borges, Alessandra Bühler [UNESP

    2013-01-01

    Aim: The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. Materials and methods: A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, accordin...

  3. Clean and polymer-free transfer of CVD-grown graphene films on hexagonal boron nitride substrates

    Science.gov (United States)

    Fujihara, Miho; Ogawa, Shun; Yoshimura, Shintaro; Inoue, Ryosuke; Maniwa, Yutaka; Taniguchi, Takashi; Watanabe, Kenji; Shinohara, Hisanori; Miyata, Yasumitsu

    2017-05-01

    This report describes the development of a solution-assisted, polymer-free transfer method and the characterization of chemical vapor deposition (CVD)-grown graphene on hexagonal boron nitride. Raman analysis reveals that polymer-free samples have small variations in G- and 2D-mode Raman frequencies and are minimally affected by charge doping as observed for clean exfoliated graphene. Electrical measurements indicate that charge doping, hysteresis, and carrier scattering are suppressed in polymer-free samples. The results demonstrate that this method provides a simple and effective way to prepare clean heterostructures of CVD-grown, large-area graphene and other two-dimensional materials.

  4. Contribution to understanding and controlling a-Si:H thin films growth by mercury-sensitised photo-CVD

    International Nuclear Information System (INIS)

    Barhdadi, A.

    2003-09-01

    Mercury-sensitized photo-CVD technique is widely used for growing amorphous silicon thin films. This attractive method allows damage-free thin film depositions at very low substrate temperatures without the deleterious effects of the other processes. This review reports on the principle and potential of this technique. It also recalls and summarizes some fundamental issues such as experimental systems or apparatus particularities, the analysis of gas-phase reactions in the reactor, the surface-reaction model of SiH 3 and H during the film growth and all the kinetic model for lamp-induced Photo-CVD. (author)

  5. Study of the triton-burnup process in different JET scenarios using neutron monitor based on CVD diamond

    Energy Technology Data Exchange (ETDEWEB)

    Nemtsev, G., E-mail: g.nemtsev@iterrf.ru; Amosov, V.; Meshchaninov, S.; Rodionov, R. [Institution “Project center ITER,” Moscow (Russian Federation); Popovichev, S. [CCFE, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Collaboration: EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2016-11-15

    We present the results of analysis of triton burn-up process using the data from diamond detector. Neutron monitor based on CVD diamond was installed in JET torus hall close to the plasma center. We measure the part of 14 MeV neutrons in scenarios where plasma current varies in a range of 1-3 MA. In this experiment diamond neutron monitor was also able to detect strong gamma bursts produced by runaway electrons arising during the disruptions. We can conclude that CVD diamond detector will contribute to the study of fast particles confinement and help predict the disruption events in future tokamaks.

  6. Electrocardiographic spatial QRS-T angle and incident cardiovascular disease in HIV-infected patients (from the Strategies for the Management of Antiretroviral Therapy [SMART] study)

    DEFF Research Database (Denmark)

    Dawood, Farah Z; Khan, Faraaz; Roediger, Mollie P

    2013-01-01

    the baseline resting 12-lead electrocardiogram of 4,453 HIV-infected patients aged 43.5 ± 9.3 years from the Strategies for Management of Antiretroviral Therapy (SMART) trial. CVD events were identified during a median follow-up of 28.7 months. Quartiles of the spatial QRS-T angle was calculated for men......Widening of the electrocardiographic (ECG) spatial QRS-T angle has been predictive of cardiovascular disease (CVD) events in the general population. However, its prognostic significance in human immunodeficiency virus (HIV)-infected patients remains unknown. The spatial QRS-T angle was derived from...... and women separately, and values in the upper quartile were considered as a widened angle (values >74° for women and >93° for men). A multivariate Cox proportional hazards analysis was used to examine the association between a widened baseline spatial QRS-T angle and incident CVD events. During 11...

  7. Police Incident Blotter (Archive)

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Police Blotter Archive contains crime incident data after it has been validated and processed to meet Uniform Crime Reporting (UCR) standards, published on a...

  8. 2011 Japanese Nuclear Incident

    Science.gov (United States)

    EPA’s RadNet system monitored the environmental radiation levels in the United States and parts of the Pacific following the Japanese Nuclear Incident. Learn about EPA’s response and view historical laboratory data and news releases.

  9. Prediction of Safety Incidents

    Data.gov (United States)

    National Aeronautics and Space Administration — Safety incidents, including injuries, property damage and mission failures, cost NASA and contractors thousands of dollars in direct and indirect costs. This project...

  10. Marine Animal Incident Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Large whale stranding, death, ship strike and entanglement incidents are all recorded to monitor the health of each population and track anthropogenic factors that...

  11. Acute incidents during anaesthesia

    African Journals Online (AJOL)

    management of acute incidents and the prevention of ... High or total (complete) spinal blocks in obstetric .... Pain and opioid analgesics lead to delayed ... Step up postoperative care and use ... recognise suprasternal and supraclavicular.

  12. OSL and TL dosimeter characterization of boron doped CVD diamond films

    Science.gov (United States)

    Gonçalves, J. A. N.; Sandonato, G. M.; Meléndrez, R.; Chernov, V.; Pedroza-Montero, M.; De la Rosa, E.; Rodríguez, R. A.; Salas, P.; Barboza-Flores, M.

    2005-04-01

    Natural diamond is an exceptional prospect for clinical radiation dosimetry due to its tissue-equivalence properties and being chemically inert. The use of diamond in radiation dosimetry has been halted by the high market price; although recently the capability of growing high quality CVD diamond has renewed the interest in using diamond films as radiation dosimeters. In the present work we have characterized the dosimetric properties of diamond films synthesized by the HFCVD method. The thermoluminescence and the optically stimulated luminescence of beta exposed diamond sample containing a B/C 4000 ppm doping presents excellent properties suitable for dosimetric applications with β-ray doses up to 3.0 kGy. The observed OSL and TL performance is reasonable appropriate to justify further investigation of diamond films as dosimeters for ionizing radiation, specially in the radiotherapy field where very well localized and in vivo and real time radiation dose applications are essential.

  13. X-ray diffraction characterization of epitaxial CVD diamond films with natural and isotopically modified compositions

    Energy Technology Data Exchange (ETDEWEB)

    Prokhorov, I. A., E-mail: igor.prokhorov@mail.ru [Russian Academy of Sciences, Space Materials Science Laboratory, Shubnikov Institute of Crystallography, Federal Scientific Research Centre “Crystallography and Photonics”, Kaluga Branch (Russian Federation); Voloshin, A. E. [Russian Academy of Sciences, Shubnikov Institute of Crystallography, Federal Scientific Research Centre “Crystallography and Photonics” (Russian Federation); Ralchenko, V. G.; Bolshakov, A. P. [Russian Academy of Sciences, Prokhorov General Physics Institute (Russian Federation); Romanov, D. A. [Bauman Moscow State Technical University, Kaluga Branch (Russian Federation); Khomich, A. A. [Russian Academy of Sciences, Prokhorov General Physics Institute (Russian Federation); Sozontov, E. A. [National Research Centre “Kurchatov Institute” (Russian Federation)

    2016-11-15

    Comparative investigations of homoepitaxial diamond films with natural and modified isotopic compositions, grown by chemical vapor deposition (CVD) on type-Ib diamond substrates, are carried out using double-crystal X-ray diffractometry and topography. The lattice mismatch between the substrate and film is precisely measured. A decrease in the lattice constant on the order of (Δa/a){sub relax} ∼ (1.1–1.2) × 10{sup –4} is recorded in isotopically modified {sup 13}C (99.96%) films. The critical thicknesses of pseudomorphic diamond films is calculated. A significant increase in the dislocation density due to the elastic stress relaxation is revealed by X-ray topography.

  14. Spent Nuclear Fuel (SNF) Cold Vacuum Drying (CVD) Facility Operations Manual; FINAL

    International Nuclear Information System (INIS)

    IRWIN, J.J.

    1999-01-01

    This document provides the Operations Manual for the Cold Vacuum Drying Facility (CVDF). The Manual was developed in conjunction with HNF-553, Spent Nuclear Fuel Project Final Safety Analysis Report Annex B-Cold Vacuum Drying Facility. The HNF-SD-SNF-DRD-002, 1999, Cold Vacuum Drying Facility Design Requirements, Rev. 4, and the CVDF Final Design Report. The Operations Manual contains general descriptions of all the process, safety and facility systems in the CVDF, a general CVD operations sequence and references to the CVDF System Design Descriptions (SDDs). This manual has been developed for the SNFP Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved

  15. A Bayesian method to estimate the neutron response matrix of a single crystal CVD diamond detector

    International Nuclear Information System (INIS)

    Reginatto, Marcel; Araque, Jorge Guerrero; Nolte, Ralf; Zbořil, Miroslav; Zimbal, Andreas; Gagnon-Moisan, Francis

    2015-01-01

    Detectors made from artificial chemical vapor deposition (CVD) single crystal diamond are very promising candidates for applications where high resolution neutron spectrometry in very high neutron fluxes is required, for example in fusion research. We propose a Bayesian method to estimate the neutron response function of the detector for a continuous range of neutron energies (in our case, 10 MeV ≤ E n ≤ 16 MeV) based on a few measurements with quasi-monoenergetic neutrons. This method is needed because a complete set of measurements is not available and the alternative approach of using responses based on Monte Carlo calculations is not feasible. Our approach uses Bayesian signal-background separation techniques and radial basis function interpolation methods. We present the analysis of data measured at the PTB accelerator facility PIAF. The method is quite general and it can be applied to other particle detectors with similar characteristics

  16. Study of the structural evolutions of crystalline tungsten oxide films prepared using hot-filament CVD

    International Nuclear Information System (INIS)

    Feng, P X; Wang, X P; Zhang, H X; Yang, B Q; Wang, Z B; Gonzalez-BerrIos, A; Morell, G; Weiner, B

    2007-01-01

    Structural evolutions of tungsten oxide(WO 3 ) samples on different substrates are studied using Raman spectroscopy, scanning electron microscopy, energy dispersive spectroscopy, x-ray diffraction and x-ray photoelectron spectroscopy. The WO 3 samples are prepared using hot-filament CVD techniques. The focus of the study is on the evolutions of nano structures at different stages following deposition time. The experimental measurements reveal evolutions of the surface structures from uniform film to fractal-like structures, and eventually to nano particles, and crystalline structures from mono (0 1 0) crystalline thin film to polycrystalline thick film developments. The effect of high temperature on the nanostructured WO 3 is also investigated. Well-aligned nanoscale WO 3 rod arrays are obtained at a substrate temperature of up to 1400 deg. C. Further increasing the substrate temperature yields microscale crystalline WO 3 particles

  17. Simulation and experimental approach to CVD-FBR aluminide coatings on ferritic steels under steam oxidation

    International Nuclear Information System (INIS)

    Leal, J.; Alcala, G.; Bolivar, F.J.; Sanchez, L.; Hierro, M.P.; Perez, F.J.

    2008-01-01

    The ferritic steels used to produce structural components for steam turbines are susceptible to strong corrosion and creep damage due to the extreme working conditions pushed to increase the process efficiency and to reduce pollutants release. The response of aluminide coatings on the P-92 ferritic steel, deposited by CVD-FBR, during oxidation in a simulated steam environment was studied. The analyses were performed at 650 deg. C in order to simulate the working conditions of a steam turbine, and 800 deg. C in order to produce a critical accelerated oxidation test. The Thermo-Calc software was used to predict the different solid phases that could be generated during the oxidation process, in both, coated and uncoated samples. In order to validate the thermodynamic results, the oxides scales produced during steam tests were characterized by different techniques such as XRD, SEM and EDS. The preliminary results obtained are discussed in the present work

  18. CVD-grown horizontally aligned single-walled carbon nanotubes: synthesis routes and growth mechanisms.

    Science.gov (United States)

    Ibrahim, Imad; Bachmatiuk, Alicja; Warner, Jamie H; Büchner, Bernd; Cuniberti, Gianaurelio; Rümmeli, Mark H

    2012-07-09

    Single-walled carbon nanotubes (SWCNTs) have attractive electrical and physical properties, which make them very promising for use in various applications. For some applications however, in particular those involving electronics, SWCNTs need to be synthesized with a high degree of control with respect to yield, length, alignment, diameter, and chirality. With this in mind, a great deal of effort is being directed to the precision control of vertically and horizontally aligned nanotubes. In this review the focus is on the latter, horizontally aligned tubes grown by chemical vapor deposition (CVD). The reader is provided with an in-depth review of the established vapor deposition orientation techniques. Detailed discussions on the characterization routes, growth parameters, and growth mechanisms are also provided. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Graphene growth on Ge(100)/Si(100) substrates by CVD method.

    Science.gov (United States)

    Pasternak, Iwona; Wesolowski, Marek; Jozwik, Iwona; Lukosius, Mindaugas; Lupina, Grzegorz; Dabrowski, Pawel; Baranowski, Jacek M; Strupinski, Wlodek

    2016-02-22

    The successful integration of graphene into microelectronic devices is strongly dependent on the availability of direct deposition processes, which can provide uniform, large area and high quality graphene on nonmetallic substrates. As of today the dominant technology is based on Si and obtaining graphene with Si is treated as the most advantageous solution. However, the formation of carbide during the growth process makes manufacturing graphene on Si wafers extremely challenging. To overcome these difficulties and reach the set goals, we proposed growth of high quality graphene layers by the CVD method on Ge(100)/Si(100) wafers. In addition, a stochastic model was applied in order to describe the graphene growth process on the Ge(100)/Si(100) substrate and to determine the direction of further processes. As a result, high quality graphene was grown, which was proved by Raman spectroscopy results, showing uniform monolayer films with FWHM of the 2D band of 32 cm(-1).

  20. Spent Nuclear Fuel (SNF) Cold Vacuum Drying (CVD) Facility Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    IRWIN, J.J.

    1999-07-02

    This document provides the Operations Manual for the Cold Vacuum Drying Facility (CVDF). The Manual was developed in conjunction with HNF-553, Spent Nuclear Fuel Project Final Safety Analysis Report Annex B--Cold Vacuum Drying Facility. The HNF-SD-SNF-DRD-002, 1999, Cold Vacuum Drying Facility Design Requirements, Rev. 4, and the CVDF Final Design Report. The Operations Manual contains general descriptions of all the process, safety and facility systems in the CVDF, a general CVD operations sequence and references to the CVDF System Design Descriptions (SDDs). This manual has been developed for the SNFP Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

  1. Spent Nuclear Fuel (SNF) Project Cold Vacuum Drying (CVD) Facility Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    IRWIN, J.J.

    2000-02-03

    This document provides the Operations Manual for the Cold Vacuum Drying Facility (CVDF). The Manual was developed in conjunction with HNF-SD-SNF-SAR-002, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of the Processing Systems (Garvin 1998) and, the HNF-SD-SNF-DRD-002, 1997, Cold Vacuum Drying Facility Design Requirements, Rev. 3a. The Operations Manual contains general descriptions of all the process, safety and facility systems in the CVDF, a general CVD operations sequence, and has been developed for the spent nuclear fuel project (SNFP) Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

  2. Visible light irradiation-induced conductivity change for CVD-grown graphene on different substrates

    Science.gov (United States)

    Li, Xiangdi; Zhang, Peng; Liu, Xianming; Cao, Xueying; Lei, Xiaohua; Chen, Weimin

    2017-08-01

    This research examines the influence of lighting on the electrical properties of graphene on different substrates, including PET, glass and SiO2, which are the most widely used substrate materials representing the flexible and rigid applications. The graphene sheets were prepared by CVD and subsequently transferred to three substrates. The resistances of graphene under periodic visible light irradiation were measured inside a vacuum chamber. Results show that the resistances for graphene samples on all substrates increased slowly under lighting, while decreased slowly as well after the light was switched off. The change degree and speed were different for graphene on different substrates, which were influenced as well by the illumination time, environment atmosphere and irradiation power. Graphene on flexible PET substrate is more stable than that on other substrates.

  3. Size modulation of nanocrystalline silicon embedded in amorphous silicon oxide by Cat-CVD

    International Nuclear Information System (INIS)

    Matsumoto, Y.; Godavarthi, S.; Ortega, M.; Sanchez, V.; Velumani, S.; Mallick, P.S.

    2011-01-01

    Different issues related to controlling size of nanocrystalline silicon (nc-Si) embedded in hydrogenated amorphous silicon oxide (a-SiO x :H) deposited by catalytic chemical vapor deposition (Cat-CVD) have been reported. Films were deposited using tantalum (Ta) and tungsten (W) filaments and it is observed that films deposited using tantalum filament resulted in good control on the properties. The parameters which can affect the size of nc-Si domains have been studied which include hydrogen flow rate, catalyst and substrate temperatures. The deposited samples are characterized by X-ray diffraction, HRTEM and micro-Raman spectroscopy, for determining the size of the deposited nc-Si. The crystallite formation starts for Ta-catalyst around the temperature of 1700 o C.

  4. Superconductivity and low temperature electrical transport in B-doped CVD nanocrystalline diamond

    Directory of Open Access Journals (Sweden)

    Milos Nesladek, Jiri J. Mares, Dominique Tromson, Christine Mer, Philippe Bergonzo, Pavel Hubik and Jozef Kristofik

    2006-01-01

    Full Text Available In this work, we report on superconductivity (SC found in thin B-doped nanocrystalline diamond films, prepared by the PE-CVD technique. The thickness of the films varies from about 100 to 400 nm, the films are grown on low-alkaline glass at substrate temperatures of about 500–700 °C. The SIMS measurements show that films can be heavily doped with boron in concentrations in the range of 3×1021 cm−3. The Raman spectra show Fano resonances, confirming the substitutional B-incorporation. The low temperature magnetotransport measurements reveal a positive magnetoresistance. The SC transition is observed at about Tc=1.66 K. A simple theory exploiting the concept of weak localization accounting for this transition is proposed.

  5. A CVD diamond detector for (n,α) cross-section measurements

    International Nuclear Information System (INIS)

    Weiss, C.

    2014-01-01

    A novel detector based on the chemical vapor deposition (CVD) diamond technology has been developed in the framework of this PhD, for the experimental determination of (n,α) cross-sections at the neutron time-of-flight facility n⎽TOF at CERN. The 59 Ni(n,α) 56 Fe cross-section, which is relevant for astrophysical questions as well as for risk-assessment studies in nuclear technology, has been measured in order to validate the applicability of the detector for such experiments. The thesis is divided in four parts. In the introductory part the motivation for measuring (n,α) cross-sections, the experimental challenges for such measurements and the reasons for choosing the CVD diamond technology for the detector are given. This is followed by the presentation of the n⎽TOF facility, an introduction to neutron-induced nuclear reactions and a brief summary of the interaction of particles with matter. The CVD diamond technology and the relevant matters related to electronics are given as well in this first part of the thesis. The second part is dedicated to the design and production of the Diamond Mosaic-Detector (DM-D) and its characterization. The 59 Ni(n,α) 56 Fe cross-section measurement at n⎽TOF and the data analysis are discussed in detail in the third part of the thesis, before the summary of the thesis and an outlook to possible future developments and applications conclude the thesis in the forth part. In this work, the Diamond Mosaic-Detector, which consist of eight single-crystal (sCVD) diamond sensors and one 'Diamond on Iridium' (DOI) sensor has proven to be well suited for (n,α) cross-section measurements for 1 MeV < E α < 22 MeV. The upper limit is given by the thickness of the sensors, d = 150 μm, while the lower limit is dictated by background induced by neutron capture reactions in in-beam materials. The cross-section measurement was focussed on the resonance integral of 59 Ni(n,α) 56 Fe at E n = 203 eV, with the aim of clarifying

  6. Synthesis and Optimization of MWCNTs on Co-Ni/MgO by Thermal CVD

    Directory of Open Access Journals (Sweden)

    H. Ryu

    2008-01-01

    Full Text Available Multiwalled carbon nanotubes (MWCNTs were prepared by the thermal chemical vapor deposition (CVD technique. Monometallic and bimetallic Co and Ni combinations were used as a catalyst on MgO support. The mixer of H2/C2H2 was used as a carbon source. The prepared CNTs were found to possess different shapes, morphologies, and sizes. Maximum yield was found for 50% Co (MgO: 50% and Ni: 0% catalyst at 600°C. Scanning electron microscopy (SEM and high-resolution transmission electron microscopy (HRTEM techniques were used for structural analysis. Raman spectra were taken to investigate the quality and crystalline perfection of the prepared CNTs. The ratio of D- and G-bands (ID/IG was measured from these spectra.

  7. Spent Nuclear Fuel (SNF) Project Cold Vacuum Drying (CVD) Facility Operations Manual

    International Nuclear Information System (INIS)

    IRWIN, J.J.

    2000-01-01

    This document provides the Operations Manual for the Cold Vacuum Drying Facility (CVDF). The Manual was developed in conjunction with HNF-SD-SNF-SAR-002, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of the Processing Systems (Garvin 1998) and, the HNF-SD-SNF-DRD-002, 1997, Cold Vacuum Drying Facility Design Requirements, Rev. 3a. The Operations Manual contains general descriptions of all the process, safety and facility systems in the CVDF, a general CVD operations sequence, and has been developed for the spent nuclear fuel project (SNFP) Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved

  8. Enhanced intrinsic voltage gain in artificially stacked bilayer CVD graphene field effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Himadri; Kataria, Satender [RWTH Aachen University, Chair for Electronic Devices, Aachen (Germany); University of Siegen, School of Science and Technology, Siegen (Germany); Aguirre-Morales, Jorge-Daniel; Fregonese, Sebastien; Zimmer, Thomas [IMS Laboratory, Centre National de la Recherche Scientifique, University of Bordeaux, Talence (France); Passi, Vikram [University of Siegen, School of Science and Technology, Siegen (Germany); AMO GmbH, Advanced Microelectronics Center Aachen (Germany); Iannazzo, Mario; Alarcon, Eduard [Technical University of Catalonia, Department of Electronics Engineering, UPC, Barcelona (Spain); Lemme, Max C. [RWTH Aachen University, Chair for Electronic Devices, Aachen (Germany); University of Siegen, School of Science and Technology, Siegen (Germany); AMO GmbH, Advanced Microelectronics Center Aachen (Germany)

    2017-11-15

    We report on electronic transport in dual-gate, artificially stacked bilayer graphene field effect transistors (BiGFETs) fabricated from large-area chemical vapor deposited (CVD) graphene. The devices show enhanced tendency to current saturation, which leads to reduced minimum output conductance values. This results in improved intrinsic voltage gain of the devices when compared to monolayer graphene FETs. We employ a physics based compact model originally developed for Bernal stacked bilayer graphene FETs (BSBGFETs) to explore the observed phenomenon. The improvement in current saturation may be attributed to increased charge carrier density in the channel and thus reduced saturation velocity due to carrier-carrier scattering. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. Structural Transformation upon Nitrogen Doping of Ultrananocrystalline Diamond Films by Microwave Plasma CVD

    Directory of Open Access Journals (Sweden)

    Chien-Chung Teng

    2009-01-01

    Full Text Available The molecular properties and surface morphology of undoped and N-doped ultra-nanocrystalline diamond (UNCD films deposited by microwave plasma CVD with addition of nitrogen are investigated with various spectroscopic techniques. The results of spatially resolved Raman scattering, ATR/FT-IR and XPS spectra show more amorphous and sp2/sp3 ratio characteristics in N-doped UNCD films. The surface morphology in AFM scans shows larger nanocrystalline diamond clusters in N-doped UNCD films. Incorporation of nitrogen into UNCD films has promoted an increase of amorphous sp2-bonded carbons in the grain boundaries and the size of nanocrystalline diamond grains that are well correlated to the reported enhancement of conductivity and structural changes of UNCD films.

  10. The CVD graphene transfer procedure introduces metallic impurities which alter the graphene electrochemical properties.

    Science.gov (United States)

    Ambrosi, Adriano; Pumera, Martin

    2014-01-07

    High quality graphene films can be fabricated by chemical vapor deposition (CVD) using Ni and Cu as catalytic substrates. Such a synthesis procedure always requires a subsequent transfer process to be performed in order to eliminate the metallic substrate and transfer the graphene onto the desired surface. We show here that such a transfer process causes significant contamination of the graphene film with residual Fe and Ni metal impurities. Fe contamination derives from the use of Fe-based etching solutions to dissolve Ni (or Cu) substrates, while residual Ni (or Cu) is due to an incomplete metal substrate etching. The presence of these metallic impurities within the transferred graphene film affects tremendously its electrochemical behavior when adopted as an electrode material.

  11. Design and application of CVD diamond windows for x-rays at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Jaski, Y.; Cookson, D.

    2007-01-01

    Two types of directly cooled, 0.2-mm-thick, 8-mm-diameter clear aperture CVD diamond windows have been designed and successfully fabricated by two different vendors for use at the Advanced Photon Source (APS). Both windows contain a direct braze joint between the diamond and the cooled OFHC copper. These windows can be used to replace the front-end beryllium windows in high-heat-load applications and can be used as white beam windows in the beamlines. This paper presents the detailed design of the diamond windows, the thermal analysis of the diamond window under different thermal load configurations, as well as a complete list of the existing APS front-end beryllium window configurations and replacement scenarios. Small-angle scattering experiments have been conducted on both diamond windows and a polished beryllium window, and the results are presented.

  12. Fast method for reactor and feature scale coupling in ALD and CVD

    Science.gov (United States)

    Yanguas-Gil, Angel; Elam, Jeffrey W.

    2017-08-08

    Transport and surface chemistry of certain deposition techniques is modeled. Methods provide a model of the transport inside nanostructures as a single-particle discrete Markov chain process. This approach decouples the complexity of the surface chemistry from the transport model, thus allowing its application under general surface chemistry conditions, including atomic layer deposition (ALD) and chemical vapor deposition (CVD). Methods provide for determination of determine statistical information of the trajectory of individual molecules, such as the average interaction time or the number of wall collisions for molecules entering the nanostructures as well as to track the relative contributions to thin-film growth of different independent reaction pathways at each point of the feature.

  13. Aluminum and aluminum/silicon coatings on ferritic steels by CVD-FBR technology

    International Nuclear Information System (INIS)

    Perez, F.J.; Hierro, M.P.; Trilleros, J.A.; Carpintero, M.C.; Sanchez, L.; Bolivar, F.J.

    2006-01-01

    The use of chemical vapor deposition by fluidized bed reactors (CVD-FBR) offers some advantages in comparison to other coating techniques such as pack cementation, because it allows coating deposition at lower temperatures than pack cementation and at atmospheric pressure without affecting the mechanical properties of material due to heat treatments of the bulk during coating process. Aluminum and aluminum/silicon coatings have been obtained on two different ferritics steels (P-91 and P-92). The coatings were analyzed using several techniques like SEM/EDX and XRD. The results indicated that both coatings were form by Fe 2 Al 5 intermetallic compound, and in the co-deposition the Si was incorporated to the Fe 2 Al 5 structure in small amounts

  14. Ion beam induced charge and cathodoluminescence imaging of response uniformity of CVD diamond radiation detectors

    CERN Document Server

    Sellin, P J; Galbiati, A; Maghrabi, M; Townsend, P D

    2002-01-01

    The uniformity of response of CVD diamond radiation detectors produced from high quality diamond film, with crystallite dimensions of >100 mu m, has been studied using ion beam induced charge imaging. A micron-resolution scanning alpha particle beam was used to produce maps of pulse height response across the device. The detectors were fabricated with a single-sided coplanar electrode geometry to maximise their sensitivity to the surface region of the diamond film where the diamond crystallites are highly ordered. High resolution ion beam induced charge images of single crystallites were acquired that demonstrate variations in intra-crystallite charge transport and the termination of charge transport at the crystallite boundaries. Cathodoluminescence imaging of the same crystallites shows an inverse correlation between the density of radiative centres and regions of good charge transport.

  15. The CVD ZrB2 as a selective solar absorber

    Science.gov (United States)

    Randich, E.; Allred, D. D.

    Coatings of ZrB2 and TiB2 for photothermal solar absorber applications were prepared using chemical vapor deposition (CVD) techniques. Oxidation tests suggest a maximum temperature limit for air exposure of 600 K for TiB2 and 800 K for Z4B2. Both materials exhibit innate spectral selectivity with emittance at 375 K ranging from 0.06 to 0.09 and solar absorptance for ZrB2 ranging from 0.67 to 0.77 and solar absorptance for TiB2 ranging from 0.46 to 0.58. ZrB2 has better solar selectivity and more desirable oxidation behavior than TiB2. A 0.071 micrometer antireflection coating of Si3N4 deposited on the ZrB2 coating leads to an increase in absorptance from 0.77 to 0.93, while the emittance remains unchanged.

  16. Development of laser-fired contacts for amorphous silicon layers obtained by Hot-Wire CVD

    International Nuclear Information System (INIS)

    Munoz, D.; Voz, C.; Blanque, S.; Ibarz, D.; Bertomeu, J.; Alcubilla, R.

    2009-01-01

    In this work we study aluminium laser-fired contacts for intrinsic amorphous silicon layers deposited by Hot-Wire CVD. This structure could be used as an alternative low temperature back contact for rear passivated heterojunction solar cells. An infrared Nd:YAG laser (1064 nm) has been used to locally fire the aluminium through the thin amorphous silicon layers. Under optimized laser firing parameters, very low specific contact resistances (ρ c ∼ 10 mΩ cm 2 ) have been obtained on 2.8 Ω cm p-type c-Si wafers. This investigation focuses on maintaining the passivation quality of the interface without an excessive increase in the series resistance of the device.

  17. Photodecomposition of Hg - Photo - CVD monosilane. Application to hydrogenated amorphous silicon thin films

    International Nuclear Information System (INIS)

    Aka, B.

    1989-04-01

    The construction of a Hg-photo-CVD device is discussed. The system enables the manufacturing of hydrogenous thin films of amorphous silicon from monosilane compound. The reaction mechanisms taking place in the gaseous phase and at the surface, and the optimal conditions for the amorphous silicon film growth are studied. The analysis technique is based on the measurement of the difference between the condensation points of the gaseous components of the mixture obtained from the monosilane photolysis. A kinetic simplified model is proposed. Conductivity measurements are performed and the heat treatment effects are analyzed. Trace amounts of oxygen and carbon are found in the material. No Hg traces are detected by SIMS analysis [fr

  18. Prediction of the properties of PVD/CVD coatings with the use of FEM analysis

    Science.gov (United States)

    Śliwa, Agata; Mikuła, Jarosław; Gołombek, Klaudiusz; Tański, Tomasz; Kwaśny, Waldemar; Bonek, Mirosław; Brytan, Zbigniew

    2016-12-01

    The aim of this paper is to present the results of the prediction of the properties of PVD/CVD coatings with the use of finite element method (FEM) analysis. The possibility of employing the FEM in the evaluation of stress distribution in multilayer Ti/Ti(C,N)/CrN, Ti/Ti(C,N)/(Ti,Al)N, Ti/(Ti,Si)N/(Ti,Si)N, and Ti/DLC/DLC coatings by taking into account their deposition conditions on magnesium alloys has been discussed in the paper. The difference in internal stresses in the zone between the coating and the substrate is caused by, first of all, the difference between the mechanical and thermal properties of the substrate and the coating, and also by the structural changes that occur in these materials during the fabrication process, especially during the cooling process following PVD and CVD treatment. The experimental values of stresses were determined based on X-ray diffraction patterns that correspond to the modelled values, which in turn can be used to confirm the correctness of the accepted mathematical model for testing the problem. An FEM model was established for the purpose of building a computer simulation of the internal stresses in the coatings. The accuracy of the FEM model was verified by comparing the results of the computer simulation of the stresses with experimental results. A computer simulation of the stresses was carried out in the ANSYS environment using the FEM method. Structure observations, chemical composition measurements, and mechanical property characterisations of the investigated materials has been carried out to give a background for the discussion of the results that were recorded during the modelling process.

  19. CVD growth of graphene under exfoliated hexagonal boron nitride for vertical hybrid structures

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Min [SKKU Advanced Institute of Nanotechnology (SAINT) (Korea, Republic of); Center for Human Interface Nanotechnology (HINT) (Korea, Republic of); Jang, Sung Kyu [SKKU Advanced Institute of Nanotechnology (SAINT) (Korea, Republic of); Song, Young Jae [SKKU Advanced Institute of Nanotechnology (SAINT) (Korea, Republic of); Department of Physics, Sungkyunkwan University (SKKU), Suwon 440-746 (Korea, Republic of); Lee, Sungjoo, E-mail: leesj@skku.edu [SKKU Advanced Institute of Nanotechnology (SAINT) (Korea, Republic of); Center for Human Interface Nanotechnology (HINT) (Korea, Republic of); College of Information and Communication Engineering, Sungkyunkwan University (SKKU), Suwon 440-746 (Korea, Republic of)

    2015-01-15

    Graphical abstract: We have demonstrated a novel yet simple method for fabricating graphene-based vertical hybrid structures by performing the CVD growth of graphene at an h-BN/Cu interface. Our systematic Raman measurements combined with plasma etching process indicate that a graphene film is grown under exfoliated h-BN rather than on its top surface, and that an h-BN/graphene vertical hybrid structure has been fabricated. Electrical transport measurements of this h-BN/graphene, transferred on SiO2, show the carrier mobility up to approximately 2250 cm{sup 2} V{sup −1} s{sup −1}. The developed method would enable the exploration of the possibility of novel hybrid structure integration with two-dimensional material systems. - Abstract: We have demonstrated a novel yet simple method for fabricating graphene-based vertical hybrid structures by performing the CVD growth of graphene at an h-BN/Cu interface. Our systematic Raman measurements combined with plasma etching process indicate that a graphene film is grown under exfoliated h-BN rather than on its top surface, and that an h-BN/graphene vertical hybrid structure has been fabricated. Electrical transport measurements of this h-BN/graphene, transferred on SiO{sub 2}, show the carrier mobility up to approximately 2250 cm{sup 2} V{sup −1} s{sup −1}. The developed method would enable the exploration of the possibility of novel hybrid structure integration with two-dimensional material systems.

  20. Pushing the boundaries of high power lasers: low loss, large area CVD diamond

    Science.gov (United States)

    Wickham, Benjamin; Schoofs, Frank; Olsson-Robbie, Stefan; Bennett, Andrew; Balmer, Richard

    2018-02-01

    Synthetic CVD diamond has exceptional properties, including broad spectral transmission, physical and chemical robustness, and the highest thermal conductivity of any known material, making diamond an attractive material for medium to high power optical and laser applications, minimizing the detrimental effects of thermal lensing and radiation damage. Example applications include ATR prisms, Raman laser crystals, extra- and intra-cavity laser cooling. In each case the demands on the fundamental material properties and fabrication routes are slightly different. In recent years, there has been good progress in the development of low-loss, single crystal diamond, suitable for higher power densities, higher pulse rates and more demanding intra- and extra-cavity thermal management. The adoption of single crystal diamond in this area has however, been hindered by the availability of large area, low birefringence plates. To address this, we report a combination of CVD growth and processing methods that have enabled the manufacture of large, low defect substrates. A final homoepitaxial, low absorption synthesis stage has produced plates with large area (up to 16 mm edge length), low absorption (α<0.005 cm-1 at 1064 nm), and low birefringence (Δn <10-5), suitable for double-sided intra-cavity cooling. We demonstrate the practical advances in synthesis, including increasing the size while reducing in-use losses compared to previous generations of single crystal material, and practical developments in processing and implementation of the single crystal diamond parts, optimizing them for use in a state-of-the-art femto-second pulsed Ti:Sa thin disk gain module, all made in collaboration with the wider European FP7 funded Ti:Sa TD consortium.