  1. Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jost, Gregor; Mensing, Tristan; Golfier, Sven; Lawaczeck, Ruediger; Pietsch, Hubertus; Huetter, Joachim; Cibik, Levent; Gerlach, Martin; Krumrey, Michael; Fratzscher, Daniel; Arkadiev, Vladimir; Wedell, Reiner; Haschke, Michael; Langhoff, Norbert; Wust, Peter; Luedemann, Lutz [TRG Diagnostic Imaging, Bayer Schering Pharma AG, 13353 Berlin (Germany); Department of Radiotherapy, Charite Medical Centre, 13353 Berlin (Germany); TRG Diagnostic Imaging, Bayer Schering Pharma AG, 13353 Berlin (Germany); Physikalisch-Technische Bundesanstalt, 10587 Berlin (Germany); Institute of Applied Photonics e.V., 12489 Berlin (Germany); Institute for Scientific Instruments GmbH, 12489 Berlin (Germany); Department of Radiotherapy, Charite Medical Centre, 13353 Berlin (Germany)

    2009-06-15

    Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detection system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasi-monochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten K{alpha} emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement

  2. Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography

    International Nuclear Information System (INIS)

    Jost, Gregor; Mensing, Tristan; Golfier, Sven; Lawaczeck, Ruediger; Pietsch, Hubertus; Huetter, Joachim; Cibik, Levent; Gerlach, Martin; Krumrey, Michael; Fratzscher, Daniel; Arkadiev, Vladimir; Wedell, Reiner; Haschke, Michael; Langhoff, Norbert; Wust, Peter; Luedemann, Lutz

    2009-01-01

    Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detection system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasi-monochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten Kα emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement factor

  3. Protective effect of monochromatic red light of LED against the oxidative effects of microwave radiation

    International Nuclear Information System (INIS)

    Tsibulyin, O.S.; Yakimenko, Yi.L.; Sidorik, Je.P.

    2016-01-01

    Oxidative mechanisms of hazard effects of radiofrequency radiation (RFR) were elucidated recently, and this opens new approaches for the protection of living organisms against harmful effects of RFR. We demonstrate the significant protective effect and the antioxidant potential of monochromatic red light of light-emitting diodes (LED, λ = 630- 650 nm) in microwave GSM 900 MHz exposed embryos of Japanese quails

  4. Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography.

    Science.gov (United States)

    Jost, Gregor; Mensing, Tristan; Golfier, Sven; Lawaczeck, Rüdiger; Pietsch, Hubertus; Hütter, Joachim; Cibik, Levent; Gerlach, Martin; Krumrey, Michael; Fratzscher, Daniel; Arkadiev, Vladimir; Wedell, Reiner; Haschke, Michael; Langhoff, Norbert; Wust, Peter; Lüdemann, Lutz

    2009-06-01

    Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detection system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasimonochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten Kalpha emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement

  5. Dichromatic and monochromatic laser radiation effects on survival and morphology of Pantoea agglomerans

    Science.gov (United States)

    Thomé, A. M. C.; Souza, B. P.; Mendes, J. P. M.; Soares, L. C.; Trajano, E. T. L.; Fonseca, A. S.

    2017-05-01

    Despite the beneficial effects of low-level lasers on wound healing, their application for treatment of infected injuries is controversial because low-level lasers could stimulate bacterial growth exacerbating the infectious process. Thus, the aim of this work was to evaluate in vitro effects of low-level lasers on survival, morphology and cell aggregation of Pantoea agglomerans. P. agglomerans samples were isolated from human pressure injuries and cultures were exposed to low-level monochromatic and simultaneous dichromatic laser radiation to study the survival, cell aggregation, filamentation and morphology of bacterial cells in exponential and stationary growth phases. Fluence, wavelength and emission mode were those used in therapeutic protocols for wound healing. Data show no changes in morphology and cell aggregation, but dichromatic laser radiation decreased bacterial survival in exponential growth phase and monochromatic red and infrared lasers increased bacterial survival at the same fluence. Simultaneous dichromatic laser radiation induces biological effects that differ from those induced by monochromatic laser radiation and simultaneous dichromatic laser could be the option for treatment of infected pressure injuries by Pantoea agglomerans.

  6. Fast radiative transfer using monochromatic look-up tables

    International Nuclear Information System (INIS)

    Anthony Vincent, R.; Dudhia, Anu

    2017-01-01

    Line-by-line (LBL) methods of numerically solving the equations of radiative transfer can be inhibitingly slow. Operational trace gas retrieval schemes generally require much faster output than current LBL radiative transfer models can achieve. One option to speed up computation is to precalculate absorption cross sections for each absorbing gas on a fixed grid and interpolate. This work presents a general method for creating, compressing, and validating a set of individual look-up tables (LUTs) for the 11 most abundant trace gases to use the Reference Forward Model (RFM) to simulate radiances observed by the Infrared Atmospheric Sounding Interferometer (IASI) at a more operational pace. These LUTs allow the RFM to generate radiances more than 20 times faster than LBL mode and were rigorously validated for 80 different atmospheric scenarios chosen to represent variability indicative of Earth's atmosphere. More than 99% of all IASI simulated spectral channels had LUT interpolation errors of brightness temperature less than 0.02 K, several factors below the IASI noise level. Including a reduced spectral grid for radiative transfer speed up the computation by another factor of six at the expense of approximately doubling interpolation errors, still factors below IASI noise. Furthermore, a simple spectral compression scheme based upon linear interpolation is presented, which reduced the total LUT file size from 120 Gbytes to 5.6 Gbytes; a compression to just 4.4% of the original. These LUTs are openly available for use by the scientific community, whether using the RFM or to be incorporated into any forward model. - Highlights: • Method to create, compress, and validate absorption coefficient LUTs is proposed. • Allows for simulation of thermal IR radiances 20–100 times faster than line-by-line. • LUTs were created for top 11 atmospheric trace gases for nadir-viewing scenarios. • LUT interpolation errors for IASI simulations found to be factors below

  7. Radiation incidents in dentistry

    International Nuclear Information System (INIS)

    Lovelock, D.J.

    1996-01-01

    Most dental practitioners act as their own radiographer and radiologist, unlike their medical colleagues. Virtually all dental surgeons have a dental X-ray machine for intraoral radiography available to them and 40% of dental practices have equipment for dental panoramic tomography. Because of the low energy of X-ray equipment used in dentistry, radiation incidents tend to be less serious than those associated with other aspects of patient care. Details of 47 known incidents are given. The advent of the 1985 and 1988 Ionising Radiation Regulations has made dental surgeons more aware of the hazards of radiation. These regulations, and general health and safety legislation, have led to a few dental surgeons facing legal action. Because of the publicity associated with these court cases, it is expected that there will be a decrease in radiation incidents arising from the practice of dentistry. (author)

  8. A zone plate soft x-ray microscope using monochromatized undulator radiation at the beamline NE1B of the TRISTAN Accumulation Ring

    International Nuclear Information System (INIS)

    Wang, J.; Kagoshima, Y.; Miyahara, T.; Ando, M.; Aoki, S.; Anderson, E.; Attwood, D.; Kern, D.

    1995-01-01

    A soft x-ray microscope has been developed at the beamline NE1B of the 6.5-GeV TRISTAN Accumulation Ring (AR). It makes use of undulator radiation as its source and a zone plate with the outermost zone width of 50 nm as its imaging element. It has two main features. First, the undulator radiation is monochromatized by a grazing incidence grating monochromator to match to the monochromaticity requirement of the zone plate. Second, a visible light prefocus unit consisting of two objectives has been designed and installed in the x-ray microscope. The x-ray optical system of the microscope can be adjusted easily, quickly, and precisely by using this unit. The microscope can resolve 55-nm lines and spaces in a zone plate test pattern

  9. Combined tunable diode laser absorption spectroscopy and monochromatic radiation thermometry in ammonium dinitramide-based thruster

    Science.gov (United States)

    Zeng, Hui; Ou, Dongbin; Chen, Lianzhong; Li, Fei; Yu, Xilong

    2018-02-01

    Nonintrusive temperature measurements for a real ammonium dinitramide (ADN)-based thruster by using tunable diode laser absorption spectroscopy and monochromatic radiation thermometry are proposed. The ADN-based thruster represents a promising future space propulsion employing green, nontoxic propellant. Temperature measurements in the chamber enable quantitative thermal analysis for the thruster, providing access to evaluate thermal properties of the thruster and optimize thruster design. A laser-based sensor measures temperature of combustion gas in the chamber, while a monochromatic thermometry system based on thermal radiation is utilized to monitor inner wall temperature in the chamber. Additional temperature measurements of the outer wall temperature are conducted on the injector, catalyst bed, and combustion chamber of the thruster by using thermocouple, respectively. An experimental ADN thruster is redesigned with optimizing catalyst bed length of 14 mm and steady-state firing tests are conducted under various feed pressures over the range from 5 to 12 bar at a typical ignition temperature of 200°C. A threshold of feed pressure higher than 8 bar is required for the thruster's normal operation and upstream movement of the heat release zone is revealed in the combustion chamber out of temperature evolution in the chamber.

  10. Monochromaticity of optical radiation of Smith-Purcell generated by electron beam with 75 keV energy

    International Nuclear Information System (INIS)

    Adishchev, Yu.N.; Vukolov, A.V.; Karlovets, D.V.; Potylitsyn, A.P.; Kube, G.

    2005-01-01

    The monochromatism of the Smith-Purcell optical radiation generated by a 75-keV electron beam with a final emittance of ε = 0.65 x 10 -4 mm rad that passes over an optical grating with a period of D = 0.833 μm has been analyzed. It has been shown that the monochromatism (line width) of the Smith-Purcell radiation is determined not only by the angular aperture of a monochromator but also by the divergence of the electron beam [ru

  11. Studies on auger enhancement of biological systems with the use of monochromatic synchrotron radiation

    International Nuclear Information System (INIS)

    Shinohara, K.

    1985-01-01

    HeLa cells were incubated either with BrdUrd (5 x 10 -5 M) and deoxycytidine (10 -5 M) for 18 hr (corresponding to one generation time) or with gallium citrate (10 -5 M) for 24 hr. The cells on the membrane filter were irradiated with monochromatic synchrotron radiation at 0.90 A, 1.00 A, or 1.14 A and cell survival was determined by colony-forming ability. The results show that the sensitivity of BrdUrd-labeled cells was higher when they were irradiated at 0.90 a than at 100 A, but cells without BrdUrd showed no difference in sensitivity when irradiated at these two wavelengths. The growth curve of HeLa cells in the presence of gallium citrate (10 -4 M). Shows that during the test period of 20-60 hr of colony-forming ability was not affected although the growth rate decreased slightly. Data show no increase in the sensitivity of gallium-labeled HeLa cells over that of controls to irradiation with monochromatic synchrotron radiation at 1.14 A, slightly shorter than the K absorption edge for the gallium (1.196 A). Since gallium has been shown to concentrate in lysosome, the present results, suggest that the range of Auger enhancement is not great enough for interaction with DNA in nucleus from lysosome in cytoplasm, although the possibility should be considered that the accumulated number of gallium atoms (∼ 5 x 10 7 /cell) may not be enough to produce detectable enhancement effects

  12. Electron Spin Resonance of Single Crystals of Cystine Dihydrochloride Irradiated with Monochromatic UV Radiation at Various Wavelenghts

    DEFF Research Database (Denmark)

    Lund-Thomsen, E.; Nielsen, S. O.

    1972-01-01

    Single crystals of cystine dihydrochloride were irradiated at room temperature with monochromatic uv radiation. The optical bandwidth was about 20 Å for each wavelength used. Essentially two ESR centers were observed, the relative yield being approximately 1. One center is identified as the RS...

  13. Monochromatic coherent transition and diffraction radiation from a relativistic electron bunch train

    Science.gov (United States)

    Naumenko, G.; Potylitsyn, A.; Shevelev, M.; Karataev, P.; Shipulya, M.; Bleko, V.

    2018-04-01

    Electron beams of most accelerators have a bunched structure and are synchronized with the accelerating RF field. Due to modulation of the electron beam with frequency ν RF one can expect to observe resonances with frequencies ν k=kṡ ν RF in radiation spectrum generated via any spontaneous emission mechanism (k is an integer and the resonance order). In this paper we present the results of spectral measurements of coherent transition radiation (CTR) generated by an electron bunch train from the Tomsk microtron with ν RF=2.63GHz in the spectral frequency range from 8 to 35 GHz. We also measured the spectrum of coherent diffraction radiation and demonstrated that the observed spectra in both cases consist of monochromatic lines. For spectral measurements the Martin-Puplett interferometer with spectral resolution of 800 MHz (FWMH) was employed. Using a waveguide frequency cut-off we were able to exclude several spectral lines to observe higher resonance orders of up to k =7.

  14. Structural anomalies in undoped Gallium Arsenide observed in high resolution diffraction imaging with monochromatic synchrotron radiation

    Science.gov (United States)

    Steiner, B.; Kuriyama, M.; Dobbyn, R. C.; Laor, U.; Larson, D.; Brown, M.

    1988-01-01

    Novel, streak-like disruption features restricted to the plane of diffraction have recently been observed in images obtained by synchrotron radiation diffraction from undoped, semi-insulating gallium arsenide crystals. These features were identified as ensembles of very thin platelets or interfaces lying in (110) planes, and a structural model consisting of antiphase domain boundaries was proposed. We report here the other principal features observed in high resolution monochromatic synchrotron radiation diffraction images: (quasi) cellular structure; linear, very low-angle subgrain boundaries in (110) directions, and surface stripes in a (110) direction. In addition, we report systematic differences in the acceptance angle for images involving various diffraction vectors. When these observations are considered together, a unifying picture emerges. The presence of ensembles of thin (110) antiphase platelet regions or boundaries is generally consistent not only with the streak-like diffraction features but with the other features reported here as well. For the formation of such regions we propose two mechanisms, operating in parallel, that appear to be consistent with the various defect features observed by a variety of techniques.

  15. Thermoluminescence dependence on the wavelength of monochromatic UV-radiation in Cu-doped KCl and KBr at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Perez R, A.; Piters, T.; Aceves, R.; Rodriguez M, R.; Perez S, R., E-mail: rperez@cifus.uson.mx [Universidad de Sonora, Departamento de Investigaciones en Fisica, Apdo. Postal 5-088, 83190 Hermosillo, Sonora (Mexico)

    2014-08-15

    Thermoluminescence (Tl) dependence on the UV irradiation wavelengths from 200 to 500 nm in Cu-doped KCl and KBr crystals with different thermal treatment has been analyzed. Spectrum of the Tl intensity of each material show lower intensity at wavelengths longer than 420 nm. The Tl intensity depends on the irradiation wavelength. Structure of the Tl intensity spectrum of each sample is very similar to the structure of its optical absorption spectrum, indicating that at each wavelength, monochromatic radiation is absorbed to produce electronic transitions and electron hole pairs. Thermoluminescence of materials with thermal treatment at high temperature shows electron-hole trapping with less efficiency. The results show that Cu-doped alkali-halide materials are good detectors of a wide range of UV monochromatic radiations and could be used to measure UV radiation doses. (Author)

  16. Nonlinear real index of refraction variations of a gas medium due to a monochromatic radiation near resonance

    International Nuclear Information System (INIS)

    Vasconcellos, J.I.C.

    1982-01-01

    The nonlinear real index of refraction variations of a gas medium due to a strong monochromatic radiation causing saturation effects is calculated. The gas is supposed to be composed of two-level molecules with which the external field is nearly resonant. It is assumed homogeneous (hard collisions, spontaneous decay) and inhomogeneous (Doppler effect) broadening mechanisms acting on the real index of refraction of the medium. The nonlinear dispersion of the medium is studied as a function of the detuning frequencies, saturation conditions and for various ratios between the homogeneous and inhomogeneous linewidths. In particular, the modification of the index of refraction due to saturation effects are emphasized. (Author) [pt

  17. Production of X-ray transition radiation with relativistic electrons propagating at grazing incidence

    CERN Document Server

    Couillaud, C

    2002-01-01

    This paper is concerned with the production of X-ray transition radiation when a relativistic electron crosses the interface between two media of different permittivities at the grazing incidence. The production yields are derived analytically when a thick interface is considered and are compared with those obtained when the electron crosses the interface at normal incidence. The production of X-ray photons having an energy between two photoabsorption edges or close to a photoabsorption edge is also investigated. The main features of the transition radiation produced are then exhibited and it is shown that the intensity can be increased by many orders of magnitude. We also show that, at grazing incidence, the backward transition radiation has an intensity close to the forward emission one, contrary to the normal incidence case. The production of quasi-monochromatic radiation is also presented. Finally, the production of X-ray transition radiation using a multilayer radiator is considered and compared in both ...

  18. Formation of ultrashort pulses from monochromatic XUV radiation via interaction with a medium of IR-dressed He atoms

    Science.gov (United States)

    Akhmedzhanov, Timur; Antonov, Vladimir; Kocharovskaya, Olga

    Trains of high intensity ultrashort XUV pulses could find a lot of applications. Recently, a mechanism of high efficiency formation of a train of XUV pulses from quasi-monochromatic XUV field was suggested. XUV field propagates through the medium of atoms, which are space-time modulated by IR field. The field scattered by modulated atoms contains sidebands of incident XUV field frequency and, for properly chosen parameters, train of ultrashort pulses is formed at the output of the medium. In this contribution, we study formation of ultrashort pulses in the medium of He atoms. Contrary to our recent work, IR field is chosen to be weak enough, so that pulses are formed due to modulation of excited atomic levels, rather than tunnel ionization. The suggested method allows to form train of pulses with high efficiency and can be scaled to He-like ions in order to get even shorter pulses.

  19. Photon activation therapy of RG2 glioma carrying Fischer rats using stable thallium and monochromatic synchrotron radiation.

    Science.gov (United States)

    Ceberg, Crister; Jönsson, Bo-Anders; Prezado, Yolanda; Pommer, Tobias; Nittby, Henrietta; Englund, Elisabet; Grafström, Gustav; Edvardsson, Anneli; Stenvall, Anna; Strömblad, Susanne; Wingårdh, Karin; Persson, Bertil; Elleaume, Hélène; Baldetorp, Bo; Salford, Leif G; Strand, Sven-Erik

    2012-12-21

    75 RG2 glioma-carrying Fischer rats were treated by photon activation therapy (PAT) with monochromatic synchrotron radiation and stable thallium. Three groups were treated with thallium in combination with radiation at different energy; immediately below and above the thallium K-edge, and at 50 keV. Three control groups were given irradiation only, thallium only, or no treatment at all. For animals receiving thallium in combination with radiation to 15 Gy at 50 keV, the median survival time was 30 days, which was 67% longer than for the untreated controls (p = 0.0020) and 36% longer than for the group treated with radiation alone (not significant). Treatment with thallium and radiation at the higher energy levels were not effective at the given absorbed dose and thallium concentration. In the groups treated at 50 keV and above the K-edge, several animals exhibited extensive and sometimes contra-lateral edema, neuronal death and frank tissue necrosis. No such marked changes were seen in the other groups. The results were discussed with reference to Monte Carlo calculated electron energy spectra and dose enhancement factors.

  20. Photon activation therapy of RG2 glioma carrying Fischer rats using stable thallium and monochromatic synchrotron radiation

    Science.gov (United States)

    Ceberg, Crister; Jönsson, Bo-Anders; Prezado, Yolanda; Pommer, Tobias; Nittby, Henrietta; Englund, Elisabet; Grafström, Gustav; Edvardsson, Anneli; Stenvall, Anna; Strömblad, Susanne; Wingårdh, Karin; Persson, Bertil; Elleaume, Hélène; Baldetorp, Bo; Salford, Leif G.; Strand, Sven-Erik

    2012-12-01

    75 RG2 glioma-carrying Fischer rats were treated by photon activation therapy (PAT) with monochromatic synchrotron radiation and stable thallium. Three groups were treated with thallium in combination with radiation at different energy; immediately below and above the thallium K-edge, and at 50 keV. Three control groups were given irradiation only, thallium only, or no treatment at all. For animals receiving thallium in combination with radiation to 15 Gy at 50 keV, the median survival time was 30 days, which was 67% longer than for the untreated controls (p = 0.0020) and 36% longer than for the group treated with radiation alone (not significant). Treatment with thallium and radiation at the higher energy levels were not effective at the given absorbed dose and thallium concentration. In the groups treated at 50 keV and above the K-edge, several animals exhibited extensive and sometimes contra-lateral edema, neuronal death and frank tissue necrosis. No such marked changes were seen in the other groups. The results were discussed with reference to Monte Carlo calculated electron energy spectra and dose enhancement factors.

  1. RADIATION CONTAMINATION INCIDENT AT ISOLDE

    CERN Multimedia

    2000-01-01

    On 27 June 2000 three specialists were investigating a problem with the extraction electrode of the high-resolution separator (HRS) in Isolde. Whilst using an endoscope in order to have a closer look at the interior, they came into contact with radioactive dust and became contaminated. The level of contamination was low and the radiation dose received by the 3 persons was far below the effective dose limit given in the CERN Radiation Safety Manual and in the regulations of the Host States.According to the usual procedure, the Director General has set up a Fact-Finding Group and an Accident Board in order to advise him on the steps and decisions tobe taken following this incident and in particular to avoid a recurrence.

  2. Quantum effects induced by a gap in the spectrum of atom-bath coupling constants: ''Freezing'' of atomic decay and monochromatic collective radiation

    International Nuclear Information System (INIS)

    Mogilevtsev, D.S.; Kilin, S.Ya.

    1994-08-01

    A specific kind of inhibition of atomic decay (''freezing of decay) and intense monochromatic collective radiation are predicted for a single two-level atom and for a system of atoms interacting with the field bath having the gap in the spectrum of coupling constants. (author). 10 refs, 5 figs

  3. Structural anomalies in undoped gallium arsenide observed in high-resolution diffraction imaging with monochromatic synchrotron radiation

    Science.gov (United States)

    Steiner, B.; Kuriyama, M.; Dobbyn, R. C.; Laor, U.; Larson, D.

    1989-01-01

    Novel, streak-like disruption features restricted to the plane of diffraction have recently been observed in images obtained by synchrotron radiation diffraction from undoped, semi-insulating gallium arsenide crystals. These features were identified as ensembles of very thin platelets or interfaces lying in (110) planes, and a structural model consisting of antiphase domain boundaries was proposed. We report here the other principal features observed in high resolution monochromatic synchrotron radiation diffraction images: (quasi) cellular structure; linear, very low-angle subgrain boundaries in (110) directions, and surface stripes in a (110) direction. In addition, we report systematic differences in the acceptance angle for images involving various diffraction vectors. When these observations are considered together, a unifying picture emerges. The presence of ensembles of thin (110) antiphase platelet regions or boundaries is generally consistent not only with the streak-like diffraction features but with the other features reported here as well. For the formation of such regions we propose two mechanisms, operating in parallel, that appear to be consistent with the various defect features observed by a variety of techniques.

  4. Nitrogen capillary plasma as a source of intense monochromatic radiation at 2.88 nm

    Czech Academy of Sciences Publication Activity Database

    Vrba, Pavel; Vrbová, M.; Zakharov, S.V.; Zakharov, V.S.; Jančárek, A.; Nevrkla, M.

    2014-01-01

    Roč. 196, October (2014), s. 24-30 ISSN 0368-2048 R&D Projects: GA ČR GAP102/12/2043; GA MŠk(CZ) LG13029 Grant - others:GA MŠk(CZ) CZ.1.07/2.3.00/20.0092 Institutional support: RVO:61389021 Keywords : Capillary Z-pinch * Water window radiation source * RHMD Code Z* Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.436, year: 2014 http://dx.doi.org/10.1016/j.elspec.2013.12.015

  5. Incidence and latency of radiation reactions

    International Nuclear Information System (INIS)

    Bentzen, S.M.; Thames, H.D.

    1989-01-01

    Like any other pathological condition, radiation reactions are characterized not only by their incidence (i.e. frequency) but also buy their latent period. The difference between latencies is the basis for the biologically and clinically important distinction between early and late radiation reactions. The authors conclude in this letter that a hazard-rate type of analysis does not allow separation of the effects of incidency and latency. The authors feel that a more adequate framework for analysis of latent-time distributions is provided bu the mixture model. Currenctly, the hydronephrosis data by Knowles and Trott are being reanalyzed using the model. (author). 8 refs.; 1 fig

  6. Semiclassical interaction between monochromatic electromagnetic radiation and an atom with two unstable levels; some fallacious works by Kamenov-Bonchev

    International Nuclear Information System (INIS)

    Romashev, Yu. A.; Skorobogatov, G.A.

    1999-01-01

    The solution of the time-dependent Hamiltonian for the classical dipole interaction of a two-level atom with a monochromatic electromagnetic wave is presented. Both atomic energy levels are assumed to be unstable. The amplitudes and probabilities of transitions between the energy levels as well as the cross-sections of resonance absorption and induced emission are obtained explicitly. It is shown that in both stationary and nonstationary limits the instability of the lower level does not lead to a differential cross section of induced emission larger than those obtained from the Breit-Wigner formula in the standard collision theory. (authors)

  7. Orbital effects of a monochromatic plane gravitational wave with ultra-low frequency incident on a gravitationally bound two-body system

    Directory of Open Access Journals (Sweden)

    Lorenzo Iorio

    2014-09-01

    Full Text Available We analytically compute the long-term orbital variations of a test particle orbiting a central body acted upon by an incident monochromatic plane gravitational wave. We assume that the characteristic size of the perturbed two-body system is much smaller than the wavelength of the wave. Moreover, we also suppose that the wave's frequency νg is much smaller than the particle's orbital one nb. We make neither a priori assumptions about the direction of the wavevector kˆ nor on the orbital configuration of the particle. While the semi-major axis a is left unaffected, the eccentricity e, the inclination I, the longitude of the ascending node Ω, the longitude of pericenter ϖ and the mean anomaly ℳ undergo non-vanishing long-term changes of the form dΨ/dt=F(Kij;e,I,Ω,ω,Ψ=e,I,Ω,ϖ,M, where Kij, i,j=1,2,3 are the coefficients of the tidal matrix K. Thus, in addition to the variations of its orientation in space, the shape of the orbit would be altered as well. Strictly speaking, such effects are not secular trends because of the slow modulation introduced by K and by the orbital elements themselves: they exhibit peculiar long-term temporal patterns which would be potentially of help for their detection in multidecadal analyses of extended data records of planetary observations of various kinds. In particular, they could be useful in performing independent tests of the inflation-driven ultra-low gravitational waves whose imprint may have been indirectly detected in the Cosmic Microwave Background by the Earth-based experiment BICEP2. Our calculation holds, in general, for any gravitationally bound two-body system whose orbital frequency nb is much larger than the frequency νg of the external wave, like, e.g., extrasolar planets and the stars orbiting the Galactic black hole. It is also valid for a generic perturbation of tidal type with constant coefficients over timescales of the order of the orbital period of the perturbed particle.

  8. Radiation incident in oil well logging

    International Nuclear Information System (INIS)

    Lozada, J.A.

    1998-01-01

    On June 4th 1997 equipment failure and violation of approved procedures by a crew of workers initiated a series of events that resulted in the unnecessary exposure to neutron and gamma radiation, from a 666 GBq Am 241 Be source, of forty two workers from a well logging company in Venezuela. Due to the presence of dry mud or drilling fluids inside the logging tool, the nosepiece was screwed off the rest of the source holder; this piece was mistaken for the entire source holder thus leaving the source inside the tool. The tool was labelled for maintenance and electronic laboratory personal worked near the source for seven hours before they identify its presence. As soon as the incident was detected a contingency plan was implemented and the source could be retrieved from the tool and placed in its shipping container. The TLD badges indicate doses well below the annual limit of 20 mSv, and none of the workers involved in the incident seem to show serious health consequences from it. After the incident, in order to avoid the occurrence of similar situations, a better source and tool maintenance program was implemented, all the workers were re-trained, and area monitors were installed in all operations bases. (author)

  9. The dependence of rate coefficients and product yields upon fluence, intensity, and time in unimolecular reactions induced by monochromatic infrared radiation

    Science.gov (United States)

    Quack, M.; Humbert, P.; van den Bergh, H.

    1980-07-01

    The influence of the three parameters (with two degrees of freedom) fluence, intensity, and time on rate coefficients and product yields in collisionless Unimolecular Reactions Induced by Monochromatic Infrared Radiation (URIMIR) is discussed in some detail in terms of the recently proposed logarithmic reactant fluence plots. Model calculations for several archetypes of such plots are presented, based on solutions of the Pauli master equation and solutions of the quantum mechanical equations of motion for spectra involving many states at each level of excitation. Linear diagrams, turnups, and turnovers are found and are discussed systematically. Experimental examples re-evaluated from the literature and new measurements on the laser induced decomposition of CF2HCl are reported which nicely illustrate the various theoretical possibilities. Steady state rate coefficients for six molecules are evaluated and summarized. In some situations the intrinsic nonlinear intensity dependence of the steady state rate coefficients and deviations from simple fluence dependence of the product yields both before and at steady state are shown to be important theoretically and experimentally. The role of the reducibility of the rate coefficient matrix is discussed in connection with turnovers and with the strong influence of initial temperature that is found in the laser induced decomposition of CF2HCl.

  10. Absorption coefficient measurrement of monochromatized synchrotron radiation at 0.65 - 1.3 A interval for some biological objects

    International Nuclear Information System (INIS)

    Avakian, Ts.M.; Karabekov, I.P.; Martirossian, M.A.

    1977-01-01

    The results of the measurement of absorption coefficients for some biological objects such as pea (Pissum sativum), wheat (Triticum aestivum), tobacco (Nicotiana-tabacum-α) seeds, as well as the distilled water are presented. The measurement has been carried out on the Erevan Physical Institute Electron Accelerator synchrotron radiation beam. The good agreement of experimental and calculated data for water confirms the accuracy of the results related to other objects

  11. Discriminating electromagnetic radiation based on angle of incidence

    Science.gov (United States)

    Hamam, Rafif E.; Bermel, Peter; Celanovic, Ivan; Soljacic, Marin; Yeng, Adrian Y. X.; Ghebrebrhan, Michael; Joannopoulos, John D.

    2015-06-16

    The present invention provides systems, articles, and methods for discriminating electromagnetic radiation based upon the angle of incidence of the electromagnetic radiation. In some cases, the materials and systems described herein can be capable of inhibiting reflection of electromagnetic radiation (e.g., the materials and systems can be capable of transmitting and/or absorbing electromagnetic radiation) within a given range of angles of incidence at a first incident surface, while substantially reflecting electromagnetic radiation outside the range of angles of incidence at a second incident surface (which can be the same as or different from the first incident surface). A photonic material comprising a plurality of periodically occurring separate domains can be used, in some cases, to selectively transmit and/or selectively absorb one portion of incoming electromagnetic radiation while reflecting another portion of incoming electromagnetic radiation, based upon the angle of incidence. In some embodiments, one domain of the photonic material can include an isotropic dielectric function, while another domain of the photonic material can include an anisotropic dielectric function. In some instances, one domain of the photonic material can include an isotropic magnetic permeability, while another domain of the photonic material can include an anisotropic magnetic permeability. In some embodiments, non-photonic materials (e.g., materials with relatively large scale features) can be used to selectively absorb incoming electromagnetic radiation based on angle of incidence.

  12. Oxygen-independent inactivation of Haemophilus influenzae transforming DNA monochromatic radiation: action spectrum, effect of histidine and repair

    International Nuclear Information System (INIS)

    Cabrera-Juarez, E.; Setlow, J.K.; Swenson, P.A.; Peak, M.J.

    1976-01-01

    The action spectrum for the oxygen-independent inactivation of native transforming DNA from Haemophilus influenzae with near-UV radiation revealed a shoulder beginning at 334 and extending to 460 nm. The presence of 0.2 M histidine during irradiation produced a small increase in inactivation at 254, 290 and 313 nm, a large increase at 334 nm and a decrease in activation at 365, 405 and 460 nm. Photoreactivation did not reverse the DNA damage produced at pH 7.0 at 334, 365, 405 and 460 nm, but did reactivate the DNA after irradiation at 254, 290 and 313 nm. The inactivation of DNA irradiated at 254, 290 and 313 nm was considerably greater when the transforming ability was assayed in an excision-defective mutant compared with the wild type, although DNA irradiated at 334, 365, 405 and 460 nm showed smaller differences. These results suggest that the oxygen-independent inactivation of H.influenzae DNA at pH 7 by irradiation at 334, 365, 405 and 460 nm is caused by lesions other than pyrimidine dimers. (author)

  13. Prostate cancer incidence in Australia correlates inversely with solar radiation.

    Science.gov (United States)

    Loke, Tim W; Seyfi, Doruk; Sevfi, Doruk; Khadra, Mohamed

    2011-11-01

    What's known on the subject? and What does the study add? Increased sun exposure and blood levels of vitamin D have been postulated to be protective against prostate cancer. This is controversial. We investigated the relationship between prostate cancer incidence and solar radiation in non-urban Australia, and found a lower incidence in regions receiving more sunlight. In landmark ecological studies, prostate cancer mortality rates have been shown to be inversely related to ultraviolet radiation exposure. Investigators have hypothesised that ultraviolet radiation acts by increasing production of vitamin D, which inhibits prostate cancer cells in vitro. However, analyses of serum levels of vitamin D in men with prostate cancer have failed to support this hypothesis. This study has found an inverse correlation between solar radiation and prostate cancer incidence in Australia. Our population (previously unstudied) represents the third group to exhibit this correlation. Significantly, the demographics and climate of Australia differ markedly from those of previous studies conducted on men in the United Kingdom and the United States. • To ascertain if prostate cancer incidence rates correlate with solar radiation among non-urban populations of men in Australia. • Local government areas from each state and territory were selected using explicit criteria. Urban areas were excluded from analysis. • For each local government area, prostate cancer incidence rates and averaged long-term solar radiation were obtained. • The strength of the association between prostate cancer incidence and solar radiation was determined. • Among 70 local government areas of Australia, age-standardized prostate cancer incidence rates for the period 1998-2007 correlated inversely with daily solar radiation averaged over the last two decades. •  There exists an association between less solar radiation and higher prostate cancer incidence in Australia. © 2011 THE AUTHORS. BJU

  14. Monochromatic neutrino beams

    CERN Document Server

    Bernabeu, J; Espinoza, C; Lindroos, M

    2005-01-01

    In the last few years spectacular results have been achieved with the demonstration of non vanishing neutrino masses and flavour mixing. The ultimate goal is the understanding of the origin of these properties from new physics. In this road, the last unknown mixing [Ue3] must be determined. If it is proved to be non-zero, the possibility is open for Charge Conjugation-Parity (CP) violation in the lepton sector. This will require precision experiments with a very intense neutrino source. Here a novel method to create a monochromatic neutrino beam, an old dream for neutrino physics, is proposed based on the recent discovery of nuclei that decay fast through electron capture. Such nuclei will generate a monochromatic directional neutrino beam when decaying at high energy in a storage ring with long straight sections. We also show that the capacity of such a facility to discover new physics is impressive, so that fine tuning of the boosted neutrino energy allows precision measurements of the oscillation parameter...

  15. Monochromatic neutrino beams

    International Nuclear Information System (INIS)

    Bernabeu, Jose; Burguet-Castell, Jordi; Espinoza, Catalina; Lindroos, Mats

    2005-01-01

    In the last few years spectacular results have been achieved with the demonstration of non vanishing neutrino masses and flavour mixing. The ultimate goal is the understanding of the origin of these properties from new physics. In this road, the last unknown mixing [U e3 ] must be determined. If it is proved to be non-zero, the possibility is open for Charge Conjugation-Parity (CP) violation in the lepton sector. This will require precision experiments with a very intense neutrino source. Here a novel method to create a monochromatic neutrino beam, an old dream for neutrino physics, is proposed based on the recent discovery of nuclei that decay fast through electron capture. Such nuclei will generate a monochromatic directional neutrino beam when decaying at high energy in a storage ring with long straight sections. We also show that the capacity of such a facility to discover new physics is impressive, so that fine tuning of the boosted neutrino energy allows precision measurements of the oscillation parameters even for a [U e3 ] mixing as small as 1 degree. We can thus open a window to the discovery of CP violation in neutrino oscillations

  16. Radiation produced by electrons incident on molecules

    International Nuclear Information System (INIS)

    Moehlman, G.R.

    1977-01-01

    The work described in this thesis deals with light intensity measurements of emission spectra (1850-9000 A) produced by a continuous or pulsed beam of monoenergetic electrons (0 - 2000 eV) incident on a variety of molecular gases like H 2 , D 2 , H 2 O, HCl, NH 3 and several hydrocarbons. The emission spectra are dominated by fluorescence from excited fragments produced via dissociative excitation, besides fluorescence from excited parent molecules themselves. The experimental results thus obtained are expressed in terms of emission cross sections and lifetimes

  17. Radiation protection aspects of the incident recovery

    International Nuclear Information System (INIS)

    Tibor, Bujtas; Arpad, Nenyei

    2006-01-01

    On the 10. April 2003 a serious accident occurred at PAKS nuclear power plant. The cleaning of fuel assemblies unloaded from the reactor of unit 2 was commencing under water in the fuel-cleaning equipment in the maintenance shaft number 1. There was no chain reaction in the cleaning tank but the fission products, accumulated in the previous operational time still produced a significant heat. Due to the inadequate cooling of the cleaning tank the assemblies overheated within a few hours. After opening the lid of the tank the entering cold water caused thermal shock and significant damage to the fuel assemblies. cladding of the fuel elements opened up and the uranium dioxide pellets got also damaged. The removal of the damaged fuel assemblies and the released debris must be managed. There are technical difficulties and radiation protection problems to reduce the radiation exposure of the workers as well as the minimization of the radioactive materials released into the environment. The description of the situation and the different actions are detailed. (N.C.)

  18. Ascertaining directionality information from incident nuclear radiation

    International Nuclear Information System (INIS)

    Archambault, Brian C.; Lapinskas, Joseph R.; Wang Jing; Webster, Jeffrey A.; McDeavitt, Sean; Taleyarkhan, Rusi P.

    2011-01-01

    Highlights: → Use of tensioned metastable fluids for detection of fast neutron radiation. → Monitored neutrons with 100% gamma photon blindness capability. → Monitored direction of incoming neutron radiation from special nuclear material emissions. → Ascertained directionality of neutron source to within 30 deg. and with 80% confidence with 2000 detection events at rate of 30-40 per second. → Conducted successful blind test for determining source of neutrons from a hidden neutron emitting source. → Compared results with MCNP5-COMSOL based multi-physics model. - Abstract: Unprecedented capabilities for the detection of nuclear particles via tailored resonant acoustic systems such as the acoustic tensioned metastable fluid detection (ATMFD) systems were assessed for determining directionality of incoming fast neutrons. This paper presents advancements that expand on these accomplishments, thereby increasing the accuracy and precision of ascertaining directionality information utilizing enhanced signal processing-cum-signal analysis, refined computational algorithms, and on demand enlargement of the detector sensitive volume. Advances in the development of ATMFD systems were accomplished utilizing a combination of experimentation and theoretical modeling. Modeling methodologies include Monte-Carlo based nuclear particle transport using MCNP5 and multi-physics based assessments accounting for acoustic, structural, and electromagnetic coupling of the ATMFD system via COMSOL's multi-physics simulation platform. Benchmarking and qualification studies have been conducted with a 1 Ci Pu-Be neutron-gamma source. These results show that the specific ATMFD system used for this study can enable detection of directionality of incoming fast neutrons from the neutron source to within 30 o with 80% confidence; this required ∼2000 detection events which could be collected within ∼50 s at a detection rate of ∼30-40 per second. Blind testing was successfully

  19. Monochromatic microtomographic imaging of osteoporotic bone

    Science.gov (United States)

    Kirby, B. J.; Davis, J. R.; Grant, J. A.; Morgan, M. J.

    1997-07-01

    A monochromatic beam obtained from laboratory based instrumentation has been used for the first time to carry out a microtomographic x-ray scan of a small segment of osteoporotic bone. The resulting tomograph provides an accurate map of the x-ray linear attenuation coefficient at the characteristic energy for Cu x-rays. The bone segment was imaged in a variety of ways which are common to microtomography in order to compare the efficacy of different experimental configurations. A Si crystal monochromator was placed before the x-ray detector in order to reject radiation scattered by the sample. In addition, polychromatic scans were compared with monochromatic scans. The effects of multiple scatter can be seen upon comparison of scans with and without the second monochromator. The results indicate that beam-hardening and x-ray scattering can significantly alter an image, thereby distorting the interpretation of what is physically present in the specimen. An accurate, monochromatic tomographic scanning facility is being developed in an attempt to map meaningful physical constants for various materials.

  20. Medical management of three workers following a radiation exposure incident

    International Nuclear Information System (INIS)

    House, R.A.; Sax, S.E.; Rumack, E.R.; Holness, D.L.

    1992-01-01

    The medical management of three individuals involved in an exposure incident to whole-body radiation at a nuclear generating plant of a Canadian electrical utility is described. The exposure incident resulted in the two highest whole-body radiation doses ever received in a single event by workers in a Canadian nuclear power plant. The individual whole-body doses (127.4 mSv, 92.0 mSv, 22.4 mSv) were below the threshold for acute radiation sickness but the exposures still presented medical management problems related to assessment and counseling. Serial blood counting and lymphocyte cytogenetic analysis to corroborate the physical dosimetry were performed. All three employees experienced somatic symptoms due to stress and one employee developed post-traumatic stress disorder. This incident indicates that there is a need in such radiation exposure accidents for early and continued counseling of exposed employees to minimize the risk of development of stress-related symptoms

  1. Medical management of three workers following a radiation exposure incident

    Energy Technology Data Exchange (ETDEWEB)

    House, R.A.; Sax, S.E.; Rumack, E.R.; Holness, D.L. (Department of Occupational and Environmental Health, St. Michael' s Hospital, Toronto, Ontario (Canada))

    1992-01-01

    The medical management of three individuals involved in an exposure incident to whole-body radiation at a nuclear generating plant of a Canadian electrical utility is described. The exposure incident resulted in the two highest whole-body radiation doses ever received in a single event by workers in a Canadian nuclear power plant. The individual whole-body doses (127.4 mSv, 92.0 mSv, 22.4 mSv) were below the threshold for acute radiation sickness but the exposures still presented medical management problems related to assessment and counseling. Serial blood counting and lymphocyte cytogenetic analysis to corroborate the physical dosimetry were performed. All three employees experienced somatic symptoms due to stress and one employee developed post-traumatic stress disorder. This incident indicates that there is a need in such radiation exposure accidents for early and continued counseling of exposed employees to minimize the risk of development of stress-related symptoms.

  2. Learning from radiation incidents: the new OTHEA website

    International Nuclear Information System (INIS)

    Shaw, P V; Ely, S Y; Croueail, P; Bataille, C

    2010-01-01

    OTHEA is the name of a new website (www.othea.net), created by the Health Protection Agency (UK) and the Centre d'etude sur l'evaluation de la protection dans le domaine nucleaire (CEPN, France), and supported by several other stakeholders including national societies and associations. The website is bi-lingual (French and English) and the purpose is to share the lessons learnt from radiological incidents that have occurred in the industrial, medical, research and teaching, and other non-nuclear sectors. OTHEA contains a collection of incident reports, categorised according to the sector and the type of application, and a search facility. The reports can be freely downloaded and printed, for example for use in radiation protection training activities. To encourage dissemination, the incident reports have been made anonymous, i.e. any information that could identify a particular individual, organisation or site has been removed. Each report contains a brief summary of the incident, the radiological consequences, and the lessons learnt. The aim is not to capture every single incident, but to provide a range of reports selected according to the value of the lessons learnt. For OTHEA to be a long-term success, it needs to be sustained with new reports. Therefore users are encouraged to submit incident reports that can be considered for inclusion in OTHEA. This note summarises the background to OTHEA, and provides a description of the operating features and content at its launch in summer 2010. (note)

  3. Monochromatic metrics are generalized Berwald

    OpenAIRE

    Bartelmeß, Nina; Matveev, Vladimir S.

    2017-01-01

    We show that monochromatic Finsler metrics, i.e., Finsler metrics such that each two tangent spaces are isomorphic as normed spaces, are generalized Berwald metrics, i.e., there exists an affine connection, possibly with torsion, that preserves the Finsler function

  4. Influence of radiation and non-radiation factors on pancreatic cancer incidence among Mayak PA workers

    Energy Technology Data Exchange (ETDEWEB)

    Zhuntova, G.V.; Tokarskaya, Z.B.; Belyaeva, Z.D. [Southern Ural Biophysics Institute (SUBI), Ozyorsk (Russian Federation); Syrchikov, V.A.; Grigoryeva, E.S. [Mayak Production Association (Mayak PA), Ozyorsk (Russian Federation)

    2006-07-01

    The finding of this nested case-control study suggests that high levels of 239 Pu incorporation (239 Pu body burden > 3.7), alcohol abuse and smoking were associated with increasing the risk of pancreatic cancer among Mayak PA workers chronically exposed to ionizing radiation. The contribution of non radiation factors (alcohol abuse and smoking) to pancreatic tumor incidence is greater (AR=51%) than 239 Pu incorporation kBq; AR = 7%). No significant effect of external gamma rays ({<=} 6.8 Gy), prior exposure to chemical agents, or chronic digestive diseases was found on the incidence of pancreatic tumor. Evaluation of the absorbed alpha-radiation pancreatic dose will permit to make more exact the 239 Pu risk estimation in the further extended study.

  5. Influence of radiation and non-radiation factors on pancreatic cancer incidence among Mayak PA workers

    International Nuclear Information System (INIS)

    Zhuntova, G.V.; Tokarskaya, Z.B.; Belyaeva, Z.D.; Syrchikov, V.A.; Grigoryeva, E.S.

    2006-01-01

    The finding of this nested case-control study suggests that high levels of 239 Pu incorporation (239 Pu body burden > 3.7), alcohol abuse and smoking were associated with increasing the risk of pancreatic cancer among Mayak PA workers chronically exposed to ionizing radiation. The contribution of non radiation factors (alcohol abuse and smoking) to pancreatic tumor incidence is greater (AR=51%) than 239 Pu incorporation kBq; AR = 7%). No significant effect of external gamma rays (≤ 6.8 Gy), prior exposure to chemical agents, or chronic digestive diseases was found on the incidence of pancreatic tumor. Evaluation of the absorbed alpha-radiation pancreatic dose will permit to make more exact the 239 Pu risk estimation in the further extended study

  6. Lessons Learnt from Past Incidents and Accidents in Radiation Oncology.

    Science.gov (United States)

    Knöös, T

    2017-09-01

    The purpose of this report is to review and compile what have been and can be learnt from incidents and accidents in radiation oncology, especially in external beam and brachytherapy. Some major accidents from the last 20 years will be discussed. The relationship between major events and minor or so-called near misses is mentioned, leading to the next topic of exploring the knowledge hidden among them. The main lessons learnt from the discussion here and elsewhere are that a well-functioning and safe radiotherapy department should help staff to work with awareness and alertness and that documentation and procedures should be in place and known by everyone. It also requires that trained and educated staff with the required competences are in place and, finally, functions and responsibilities are defined and well known. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. Alteration in murine epidermal Langerhans cell population by various UV irradiations: quantitative and morphologic studies on the effects of various wavelengths of monochromatic radiation on Ia-bearing cells

    International Nuclear Information System (INIS)

    Obata, M.; Tagami, H.

    1985-01-01

    The present study was undertaken in order to clarify the exact mode of the Langerhans cell (LC) depleting process caused by UV irradiation. Following irradiation with a single dose of various wavelengths of monochromatic UV radiation (UVR), the number of Ia-positive cells were studied in mouse epidermal sheets quantitatively, particularly with regard to dose-response relationships, action spectrum, and time course change. In addition, morphologic alterations of these cells were studied using electron- and immunoelectron microscopy (EM and IEM). The authors obtained the following results after a single dose of UVB radiation (200 mJ/cm2 of 300 nm) or PUVA (1% of 8-methoxypsoralen (8-MOP) 20 microliter and 1 J/cm2 of 360 nm): (1) EM and IEM showed that while some LCs simply lost their Ia marker without any structural alterations, the majority of the LCs disappeared due to actual cell damage. (2) During an ''injury phase,'' the initial 48 h, and a ''recovery phase,'' lasting from 4-14 days after irradiation, enlargement of the size of remaining Ia-positive LCs occurred. The degree of enlargement was closely related to the degree of reduction in number, suggesting a process compensating for the loss of the LC population. (3) It was found that the recovery rate of LCs after irradiation damage was slower than that of keratinocytes, indicating different cell kinetics between these distinct cell populations in the epidermis, i.e., restoration of LCs after irradiation seems to be achieved at least partially through a repopulation process originating in the bone marrow

  8. Using mortality data to estimate radiation effects on breast cancer incidence

    International Nuclear Information System (INIS)

    Hoel, D.G.; Dinse, G.E.

    1990-01-01

    In this paper we combine Japanese data on radiation exposure and cancer mortality with U.S. data on cancer incidence and lethality to estimate the effects of ionizing radiation on cancer incidence. The analysis is based on the mathematical relationship between the mortality rate and the incidence and lethality rates, as well as on statistical models that relate Japanese incidence rates to U.S. incidence rates and radiation risk factors. Our approach assumes that the risk of death from causes other than the cancer does not depend on whether or not the cancer is present, and among individuals with the cancer, the risk of death attributable to the cancer is the same in Japan and the U.S. and is not affected by radiation exposure. In particular, we focus on the incidence of breast cancer in Japanese women and how this incidence is affected by radiation risk factors. The analysis uses Japanese exposure and mortality data from the Radiation Effects Research Foundation study of atomic bomb survivors and U.S. incidence and lethality data from the Surveillance, Epidemiology, and End Results Registry. Even without Japanese incidence data, we obtain reasonable estimates of the incidence of breast cancer in unexposed Japanese women and identify the radiation risk factors that affect this incidence. Our analysis demonstrates that the age at exposure is an important risk factor, but that the incidence of breast cancer is not affected by the city of residence (Nagasaki versus Hiroshima) or the time since exposure

  9. Survival of prototype strains of somatic coliphage families in environmental waters and when exposed to UV low-pressure monochromatic radiation or heat.

    Science.gov (United States)

    Lee, Hee Suk; Sobsey, Mark D

    2011-06-01

    The potential use of specific somatic coliphage taxonomic groups as viral indicators based on their persistence and prevalence in water was investigated. Representative type strains of the 4 major somatic coliphage taxonomic groups were seeded into reagent water and an ambient surface water source of drinking water and the survival of the added phages was measured over 90 days at temperatures of 23-25 and 4 °C. Microviridae (type strain PhiX174), Siphoviridae (type strain Lambda), and Myoviridae (type strain T4) viruses were the most persistent in water at the temperatures tested. The Microviridae (type strain PhiX174) and the Siphoviridae (type strain Lambda) were the most resistant viruses to UV radiation and the Myoviridae (type strain T4) and the Microviridae (type strain PhiX174) were the most resistant viruses to heat. Based on their greater persistence in water over time and their relative resistance to heat and/or UV radiation, the Myoviridae (type strain T4), the Microviridae (type strain PhiX174), and the Siphoviridae (type strain Lambda) were the preferred candidate somatic coliphages as fecal indicator viruses in water, with the Microviridae (type strain PhiX174) the most resistant to these conditions overall. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Dependence of extinction cross-section on incident polarization state and particle orientation

    International Nuclear Information System (INIS)

    Yang Ping; Wendisch, Manfred; Bi Lei; Kattawar, George; Mishchenko, Michael; Hu, Yongxiang

    2011-01-01

    This note reports on the effects of the polarization state of an incident quasi-monochromatic parallel beam of radiation and the orientation of a hexagonal ice particle with respect to the incident direction on the extinction process. When the incident beam is aligned with the six-fold rotational symmetry axis, the extinction is independent of the polarization state of the incident light. For other orientations, the extinction cross-section for linearly polarized light can be either larger or smaller than its counterpart for an unpolarized incident beam. Therefore, the attenuation of a quasi-monochromatic radiation beam by an ice cloud depends on the polarization state of the beam if ice crystals within the cloud are not randomly oriented. Furthermore, a case study of the extinction of light by a quartz particle is also presented to illustrate the dependence of the extinction cross-section on the polarization state of the incident light.

  11. Electromagnetic Radiation of Electrons in Periodic Structures

    CERN Document Server

    Potylitsyn, Alexander Petrovich

    2011-01-01

    Periodic magnetic structures (undulators) are widely used in accelerators to generate monochromatic undulator radiation (UR) in the range from far infrared to the hard X-ray region. Another periodic crystalline structure is used to produce quasimonochromatic polarized photon beams via the coherent bremsstrahlung mechanism (CBS). Due to such characteristics as monochromaticity, polarization and adjustability, these types of radiation is of large interest for applied and basic research of accelerator-emitted radiation. The book provides a detailed overview of the fundamental principles behind electromagnetic radiation emitted from accelerated charged particles (e.g. UR, CBS, radiation of fast electrons in Laser flash fields) as well as a unified description of relatively new radiation mechanisms which attracted great interest in recent years. This are the so-called polarization radiation excited by the Coulomb field of incident particles in periodic structures, parametric X-rays, resonant transition radiation a...

  12. Broadband, monochromatic and quasi-monochromatic x-ray propagation in multi-Z media for imaging and diagnostics.

    Science.gov (United States)

    Westphal, Maximillian S; Lim, Sara N; Nahar, Sultana N; Chowdhury, Enam; Pradhan, Anil K

    2017-07-20

    With the advent of monochromatic and quasi-monochromatic x-ray sources, we explore their potential with computational and experimental studies on propagation through a combination of low and high-Z (atomic number) media for applications to imaging and detection. The multi-purpose code GEANT4 and a new code PHOTX are employed in numerical simulations, and a variety of x-ray sources are considered: conventional broadband devices with well-known spectra, quasi-monochromatic laser driven sources, and monochromatic synchrotron x-rays. Phantom samples consisting of layers of low-Z and high-Z material are utilized, with atomic-molecular species ranging from H 2 O to gold. Differential and total attenuation of x-ray fluxes from the different x-ray sources are illustrated through simulated x-ray images. Main conclusions of this study are: I. It is shown that a 65 keV Gaussian quasi-monochromatic source is capable of better contrast with less radiation exposure than a common 120 kV broadband simulator. II. A quantitative measure is defined and computed as a metric to compare the efficacy of any two x-ray sources, as a function of concentration of high-Z moieties in predominantly low-Z environment and depth of penetration. III. Characteristic spectral features of [Formula: see text], [Formula: see text] fluorescent emission and Compton scattering indicate pathways for accelerating x-ray photoexcitation and absorption; in particular, we model the tungsten [Formula: see text] at 59 keV alongside experimental measurements at the European synchrotron research facility to search for the signature of induced [Formula: see text] resonance fluorescence. The present study should contribute to the understanding of diagnostic potential of new x-ray sources under development, as well as the underlying fundamental physical processes and features for biomedical applications.

  13. Atmospheric impacts on climatic variability of surface incident solar radiation

    Directory of Open Access Journals (Sweden)

    K. C. Wang

    2012-10-01

    Full Text Available The Earth's climate is driven by surface incident solar radiation (Rs. Direct measurements have shown that Rs has undergone significant decadal variations. However, a large fraction of the global land surface is not covered by these observations. Satellite-derived Rs has a good global coverage but is of low accuracy in its depiction of decadal variability. This paper shows that daily to decadal variations of Rs, from both aerosols and cloud properties, can be accurately estimated using globally available measurements of Sunshine Duration (SunDu. In particular, SunDu shows that since the late 1980's Rs has brightened over Europe due to decreases in aerosols but dimmed over China due to their increases. We found that variation of cloud cover determines Rs at a monthly scale but that aerosols determine the variability of Rs at a decadal time scale, in particular, over Europe and China. Because of its global availability and long-term history, SunDu can provide an accurate and continuous proxy record of Rs, filling in values for the blank areas that are not covered by direct measurements. Compared to its direct measurement, Rs from SunDu appears to be less sensitive to instrument replacement and calibration, and shows that the widely reported sharp increase in Rs during the early 1990s in China was a result of instrument replacement. By merging direct measurements collected by Global Energy Budget Archive with those derived from SunDu, we obtained a good coverage of Rs over the Northern Hemisphere. From this data, the average increase of Rs from 1982 to 2008 is estimated to be 0.87 W m−2 per decade.

  14. Simulation of Solar Radiation Incident on Horizontal and Inclined Surfaces

    Directory of Open Access Journals (Sweden)

    MA Basunia

    2012-12-01

    Full Text Available A computer model was developed to simulate the hourly, daily and monthly average of daily solar radiation on horizontal and inclined surfaces. The measured hourly and daily solar radiation was compared with simulated radiation, and favourable agreement was observed for the measured and predicted values on clear days. The measured and simulated monthly averages of total (diffuse and beam daily solar radiation were compared and a reasonable agreement was observed for a number of stations in Japan. The simulation showed that during the rice harvesting season, September to October, there is a daily average of 14.7 MJ/m2 of solar irradiation on a horizontal surface in Matsuyama, Japan. There is a similar amount of solar radiation on a horizontal surface during the major rice harvesting season, November to December, in Bangladesh. This radiation can be effectively utilized for drying rough rice and other farm crops.

  15. Monochromatic x-rays for low-dose digital mammography: preliminary results.

    Science.gov (United States)

    Yoon, Kwon-Ha; Kwon, Young Man; Choi, Byoung-Jung; Son, Hyun Hwa; Ryu, Cheol Woo; Chon, Kwon Su; Park, Seong Hoon; Juhng, Sun Kwan

    2012-12-01

    The feasibility of using monochromatic x-ray imaging generated from an x-ray tube and a multilayer reflector for digital mammography with a low radiation dose was examined. A multilayer mirror was designed to select the x-ray peak with an energy of 21.5 keV generated from an x-ray tube with a tungsten target and was fabricated by the ion-beam sputtering deposition system. Monochromatic x-ray images were obtained from an experimental digital mammography setup with a scanning stage. The performance of the system was evaluated using a breast phantom, a spectrometer, and a radiation dosimeter. We measured the contrast-to-noise ratio and performed the 10% modulation function test to determine image quality and resolution. The monochromatic beam from the multilayer reflector had a full-width-at-half-maximum of 0.9 keV at 21.5 keV, and the reflectivity was 0.70, which was 90% of the designed value. The polychromatic and monochromatic x-rays showed radiation doses of 0.497 and 0.0415 mGy, respectively. The monochromatic x-ray image shows fibers, calcifications, and masses more clearly than the polychromatic x-ray images do. The image contrast of the monochromatic x-rays was 1.85 times higher than that of the polychromatic x-rays. The experimental mammography setup had a spatial resolution of 7 lp/mm with both x-rays. Monochromatic x-rays generated using a multilayer mirror may be a useful diagnostic tool for breast examination by providing high contrast imaging with a low radiation dose.

  16. Radiation effects in silicon and gallium arsenide solar cells using isotropic and normally incident radiation

    Science.gov (United States)

    Anspaugh, B. E.; Downing, R. G.

    1984-01-01

    Several types of silicon and gallium arsenide solar cells were irradiated with protons with energies between 50 keV and 10 MeV at both normal and isotropic incidence. Damage coefficients for maximum power relative to 10 MeV were derived for these cells for both cases of omni-directional and normal incidence. The damage coefficients for the silicon cells were found to be somewhat lower than those quoted in the Solar Cell Radiation Handbook. These values were used to compute omni-directional damage coefficients suitable for solar cells protected by coverglasses of practical thickness, which in turn were used to compute solar cell degradation in two proton-dominated orbits. In spite of the difference in the low energy proton damage coefficients, the difference between the handbook prediction and the prediction using the newly derived values was negligible. Damage coefficients for GaAs solar cells for short circuit current, open circuit voltage, and maximum power were also computed relative to 10 MeV protons. They were used to predict cell degradation in the same two orbits and in a 5600 nmi orbit. Results show the performance of the GaAs solar cells in these orbits to be superior to that of the Si cells.

  17. The Equivalent Uniform Dose as a severity metric for radiation treatment incidents

    International Nuclear Information System (INIS)

    Dunscombe, Peter B.; Iftody, Sandra; Ploquin, Nicolas; Ekaette, Edidiong U.; Lee, Robert C.

    2007-01-01

    In allocating resources within a risk management program, ideally we would like to know both the probabilities and consequences of potential incidents. We simulate, on a treatment planning computer, several commonly reported incidents in radiation treatment and explore their consequences for the EUDs of targets and organs at risk

  18. Scattering of Electromagnetic Radiation by Apertures: II. Oblique Incidence on the Slotted Plane for Parallel Polarization,

    Science.gov (United States)

    The report is the second in a series of investigations into the diffraction of electromagnetic radiation by apertures in conducting screens. Herein...is presented a technique for obtaining the fields everywhere for plane electromagnetic radiation incident obliquely on a slotted conducting plane. The

  19. Grazing Incidence X-Ray Fluorescence of periodic structures – a comparison between X-ray Standing Waves and Geometrical Optics calculations.

    OpenAIRE

    Reinhardt Falk; Nowak Stanislaw H.; Beckhoff Burkhard; Dousse Jean-Claude; Schoengen Max

    2014-01-01

    Grazing incidence X-ray fluorescence spectra of nano-scaled periodic line structures were recorded at the four crystal monochromator beamline in the laboratory of the Physikalisch-Technische Bundesanstalt at the synchrotron radiation facility BESSY II. For different tilt angles between the lines and the plane of incidence of the monochromatic synchrotron radiation, spectral features are observed which can be understood and explained with calculations of the emerging X-ray standing wave (XSW) ...

  20. Are passive smoking, air pollution and obesity a greater mortality risk than major radiation incidents?

    Directory of Open Access Journals (Sweden)

    Smith Jim T

    2007-04-01

    Full Text Available Abstract Background Following a nuclear incident, the communication and perception of radiation risk becomes a (perhaps the major public health issue. In response to such incidents it is therefore crucial to communicate radiation health risks in the context of other more common environmental and lifestyle risk factors. This study compares the risk of mortality from past radiation exposures (to people who survived the Hiroshima and Nagasaki atomic bombs and those exposed after the Chernobyl accident with risks arising from air pollution, obesity and passive and active smoking. Methods A comparative assessment of mortality risks from ionising radiation was carried out by estimating radiation risks for realistic exposure scenarios and assessing those risks in comparison with risks from air pollution, obesity and passive and active smoking. Results The mortality risk to populations exposed to radiation from the Chernobyl accident may be no higher than that for other more common risk factors such as air pollution or passive smoking. Radiation exposures experienced by the most exposed group of survivors of Hiroshima and Nagasaki led to an average loss of life expectancy significantly lower than that caused by severe obesity or active smoking. Conclusion Population-averaged risks from exposures following major radiation incidents are clearly significant, but may be no greater than those from other much more common environmental and lifestyle factors. This comparative analysis, whilst highlighting inevitable uncertainties in risk quantification and comparison, helps place the potential consequences of radiation exposures in the context of other public health risks.

  1. Calorie restriction reduces the incidence of radiation-induced myeloid leukemia and spontaneous tumor

    International Nuclear Information System (INIS)

    Yoshida, Kazuko

    1999-01-01

    The host-defense mechanisms against cancers are known to be modulated by changing the environmental factor(s). The spontaneous incidence of myeloid leukemia is about 1% in C3H/He mice, and the incidence increases up to 23.3% when a single dose of radiation, 3 Gy X-ray, is exposed to a whole-body. Since calorie restriction was known to reduce the incidence of spontaneous tumors, a question as to whether such radiation induced-increase of myeloid leukemia would be also decreased by calorie restriction, was aimed to answer to elucidate possible mechanism of radiation-induced myeloid leukemia. By the calorie restriction, the incidence of myeloid leukemia was significantly decreased; it was reduced to 7.9% and 10.7% when restriction was started before (6 weeks old) and after (10 weeks old) irradiation, respectively. In addition, the latent period of the myeloid leukemia in the groups for calorie restriction was significantly extended at a greater extent as compared with the control diet groups. Number of hematopoietic stem cells, the possible target cells for radiation-induced leukemias, in the groups for the calorie restriction demonstrated a significant decrease, especially in the spleen, as compared with that in the control, when the evaluation was made at the time of radiation exposure. Then, we examined whether the decreased number of target cells at the time of exposure is caused by the reduction of radiation-induced myeloid leukemia with caloric restriction. The third restricted groups were fed 65 kcal diet (restricted diet) for the first 4 weeks i.e. from 6 weeks to 10 weeks old, then, the mice were fed with control diet after radiation. The incidence of myeloid leukemia in this group was slightly decreased but did not show statistically significance. Therefore, the caloric restriction seems to be more effective in the promotion stage than the initiation stage on radiation-induced leukemogenesis. It is well known that C3H/He mice develop hepatoma spontaneously

  2. Calorie restriction reduces the incidence of radiation-induced myeloid leukemia and spontaneous tumor

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Kazuko [National Inst. of Radiological Sciences, Chiba (Japan)

    1999-06-01

    The host-defense mechanisms against cancers are known to be modulated by changing the environmental factor(s). The spontaneous incidence of myeloid leukemia is about 1% in C3H/He mice, and the incidence increases up to 23.3% when a single dose of radiation, 3 Gy X-ray, is exposed to a whole-body. Since calorie restriction was known to reduce the incidence of spontaneous tumors, a question as to whether such radiation induced-increase of myeloid leukemia would be also decreased by calorie restriction, was aimed to answer to elucidate possible mechanism of radiation-induced myeloid leukemia. By the calorie restriction, the incidence of myeloid leukemia was significantly decreased; it was reduced to 7.9% and 10.7% when restriction was started before (6 weeks old) and after (10 weeks old) irradiation, respectively. In addition, the latent period of the myeloid leukemia in the groups for calorie restriction was significantly extended at a greater extent as compared with the control diet groups. Number of hematopoietic stem cells, the possible target cells for radiation-induced leukemias, in the groups for the calorie restriction demonstrated a significant decrease, especially in the spleen, as compared with that in the control, when the evaluation was made at the time of radiation exposure. Then, we examined whether the decreased number of target cells at the time of exposure is caused by the reduction of radiation-induced myeloid leukemia with caloric restriction. The third restricted groups were fed 65 kcal diet (restricted diet) for the first 4 weeks i.e. from 6 weeks to 10 weeks old, then, the mice were fed with control diet after radiation. The incidence of myeloid leukemia in this group was slightly decreased but did not show statistically significance. Therefore, the caloric restriction seems to be more effective in the promotion stage than the initiation stage on radiation-induced leukemogenesis. It is well known that C3H/He mice develop hepatoma spontaneously

  3. Radiation doses from global fallout and cancer incidence among reindeer herders and Sami in Northern Finland.

    Science.gov (United States)

    Kurttio, Päivi; Pukkala, Eero; Ilus, Taina; Rahola, Tua; Auvinen, Anssi

    2010-11-01

    People in the Arctic regions are one of the most heavily exposed population from the global fallout from atmospheric atomic bomb testing of the 1950s and 1960s due to their diet rich in reindeer meat in which radionuclides accumulate. We estimated the effect of the radioactive fallout and ethnicity on the cancer incidence in Northern Finland. A cohort of the Arctic population in Finland (n=34,653) was identified through the Population Register Centre with grouping by reindeer herding status, ethnicity and radiation exposure. Annual average radiation doses, based on (137)Cs whole-body measurements, were assigned by birth year, gender and reindeer herder status. Incident cancer cases of a priori selected cancer types in the study cohort during 1971-2005 were identified from the Finnish Cancer Registry. A total of 2630 cancer cases were observed versus 3073 expected on the basis of incidence rates in Northern Finland (standardised incidence ratio (SIR) was 0.86 with 95% CI of 0.82 to 0.89). For the indigenous Sami people SIR was even lower, 0.60 (95% CI 0.50 to 0.71). None of the cancer sites was significantly associated with the lifetime cumulative radiation dose. The SIR for the combined group of radiation-related cancer sites increased with the cumulative radiation dose received before 15 years of age (p=0.004). Despite the low overall cancer incidence in the Arctic population and ethnic Sami people in Finland and lack of association between the lifetime cumulative radiation exposure from global radioactive fallout and cancer incidence, we found some indication of an increased cancer risk associated with radiation exposure received during childhood. Potential underestimation and misclassification of the radiation dose may affect the results and the findings should be interpreted with caution.

  4. Relationship of cancer incidence to terrestrial radiation and population density in Connecticut, 1935-1974

    International Nuclear Information System (INIS)

    Walter, S.D.; Meigs, J.W.; Heston, J.F.

    1986-01-01

    The relationship of cancer incidence to terrestrial radiation and population density was investigated. Cancer incidence was obtained using 40 years of age-standardized data from the Connecticut Tumor Registry, and environmental radiation was estimated using data from an airborne gamma radiation survey of the entire state. These variables were examined ecologically, using the 169 towns of the state as the analytic units in a weighted regression analysis. The study design involves a large population base in a state having relatively high terrestrial radiation exposure levels overall and reasonable variation in exposure between towns. For all cancer combined, only one of the eight sex-specific analyses by decade yielded a significant radiation regression coefficient, and this was negative. In the sex- and site-specific analyses, almost all the coefficients for radiation were not significantly different from zero. In contrast, significant positive relationships of cancer incidence with population density were found for all cancer, for cancer of the lung for both sexes, for stomach, colonic, and prostatic cancer for males, and for lymphomas, thyroid, breast, and ovarian cancer for females. Both the radiation and population density relationships were adjusted for socioeconomic status. Socioeconomic status was significantly negatively associated with stomach and lung cancer in males and with cervical cancer in females; it was also positively associated with lymphomas and breast cancer in females. A power calculation revealed that, despite the relatively large size of this study, there was only a small probability of detecting a radiation effect of the strength anticipated from previous estimates

  5. The monochromatic imaging mode of a RITA-type neutron spectrometer

    DEFF Research Database (Denmark)

    Bahl, C.R.H.; Andersen, P.; Klausen, S.N.

    2004-01-01

    The imaging monochromatic mode of a neutron spectrometer with a multi-bladed RITA analyser system is so far unexplored. We present analytical calculations that define the mode. It is shown that the mode can be realised for PG (002) analyser crystals, from incident energies of about 3.2 meV and up...

  6. The cryogenic source of slow monochromatic positrons

    International Nuclear Information System (INIS)

    Meshkov, I.N.; Pavlov, V.N.; Sidorin, A.O.; Yakovenko, S.L.

    2008-01-01

    The cryogenic source of slow monochromatic positrons based on the 22 Na isotope has been designed and constructed at JINR. Positrons emitted from radioactive source 22 Na have a very broad energy spectrum up to 0.5 MeV. To generate monochromatic beam of slow positrons the solid neon is used as a moderator. The solid neon allows forming slow positron beam of the energy of 1.2 eV at the spectrum width of 1 eV. The efficiency of moderation is 1 % of total positron flux

  7. The monochromatic imaging mode of a RITA-type neutron spectrometer

    DEFF Research Database (Denmark)

    Bahl, C.R.H.; Andersen, P.; Klausen, S.N.

    2004-01-01

    The imaging monochromatic mode of a neutron spectrometer with a multi-bladed RITA analyser system is so far unexplored. We present analytical calculations that define the mode. It is shown that the mode can be realised for PG (002) analyser crystals, from incident energies of about 3.2 meV and up......, allowing the important cases of 3.7, 5.0 and 13.7 meV. Due to beam divergence, the neutron rays from neighbouring analyser blades are found to overlap slightly. Hence, the optimal use of the monochromatic imaging mode would be found by employing an adjustable radial collimator to limit the spread...

  8. Identifying Predictive Factors for Incident Reports in Patients Receiving Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Elnahal, Shereef M., E-mail: selnaha1@jhmi.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Blackford, Amanda [Department of Oncology Biostatistics, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Smith, Koren; Souranis, Annette N.; Briner, Valerie; McNutt, Todd R.; DeWeese, Theodore L.; Wright, Jean L.; Terezakis, Stephanie A. [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, Maryland (United States)

    2016-04-01

    Purpose: To describe radiation therapy cases during which voluntary incident reporting occurred; and identify patient- or treatment-specific factors that place patients at higher risk for incidents. Methods and Materials: We used our institution's incident learning system to build a database of patients with incident reports filed between January 2011 and December 2013. Patient- and treatment-specific data were reviewed for all patients with reported incidents, which were classified by step in the process and root cause. A control group of patients without events was generated for comparison. Summary statistics, likelihood ratios, and mixed-effect logistic regression models were used for group comparisons. Results: The incident and control groups comprised 794 and 499 patients, respectively. Common root causes included documentation errors (26.5%), communication (22.5%), technical treatment planning (37.5%), and technical treatment delivery (13.5%). Incidents were more frequently reported in minors (age <18 years) than in adult patients (37.7% vs 0.4%, P<.001). Patients with head and neck (16% vs 8%, P<.001) and breast (20% vs 15%, P=.03) primaries more frequently had incidents, whereas brain (18% vs 24%, P=.008) primaries were less frequent. Larger tumors (17% vs 10% had T4 lesions, P=.02), and cases on protocol (9% vs 5%, P=.005) or with intensity modulated radiation therapy/image guided intensity modulated radiation therapy (52% vs 43%, P=.001) were more likely to have incidents. Conclusions: We found several treatment- and patient-specific variables associated with incidents. These factors should be considered by treatment teams at the time of peer review to identify patients at higher risk. Larger datasets are required to recommend changes in care process standards, to minimize safety risks.

  9. Characteristics of a multi-keV monochromatic point x-ray source ...

    Indian Academy of Sciences (India)

    Temporal, spatial and spectral characteristics of a multi-keV monochromatic point x-ray source based on vacuum diode with laser-produced plasma as cathode are presented. Electrons from a laser-produced aluminium plasma were accelerated towards a conical point tip titanium anode to generate K-shell x-ray radiation.

  10. Characteristics of a multi-keV monochromatic point x-ray source

    Indian Academy of Sciences (India)

    Temporal, spatial and spectral characteristics of a multi-keV monochromatic point x-ray source based on vacuum diode with laser-produced plasma as cathode are presented. Electrons from a laser-produced aluminium plasma were accelerated towards a conical point tip titanium anode to generate K-shell x-ray radiation.

  11. RO-ILS: Radiation Oncology Incident Learning System: A report from the first year of experience.

    Science.gov (United States)

    Hoopes, David J; Dicker, Adam P; Eads, Nadine L; Ezzell, Gary A; Fraass, Benedick A; Kwiatkowski, Theresa M; Lash, Kathy; Patton, Gregory A; Piotrowski, Tom; Tomlinson, Cindy; Ford, Eric C

    2015-01-01

    Incident learning is a critical tool to improve patient safety. The Patient Safety and Quality Improvement Act of 2005 established essential legal protections to allow for the collection and analysis of medical incidents nationwide. Working with a federally listed patient safety organization (PSO), the American Society for Radiation Oncology and the American Association of Physicists in Medicine established RO-ILS: Radiation Oncology Incident Learning System (RO-ILS). This paper provides an overview of the RO-ILS background, development, structure, and workflow, as well as examples of preliminary data and lessons learned. RO-ILS is actively collecting, analyzing, and reporting patient safety events. As of February 24, 2015, 46 institutions have signed contracts with Clarity PSO, with 33 contracts pending. Of these, 27 sites have entered 739 patient safety events into local database space, with 358 events (48%) pushed to the national database. To establish an optimal safety culture, radiation oncology departments should establish formal systems for incident learning that include participation in a nationwide incident learning program such as RO-ILS. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  12. Optimizing Monochromatic Focusing on ThALES

    Czech Academy of Sciences Publication Activity Database

    Čermák, P.; Boehm, M.; Kulda, J.; Roux, S.; Hiess, A.; Steffens, P.; Šaroun, Jan

    2014-01-01

    Roč. 82, A (2014), SA026 ISSN 0031-9015 Institutional support: RVO:61389005 Keywords : Monte Carlo ray-tracing * inelastic neutron scattering * Triple-Axis spectrometer * monochromatic focusing Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.585, year: 2014

  13. Leakage of an irradiator source: The June 1988 Georgia RSI [Radiation Sterilizers, Inc.] incident

    International Nuclear Information System (INIS)

    1990-02-01

    On June 6, 1988, operators of a pool irradiator in Decatur, Georgia, were prevented by a safety system from raising sources from the pool. Radiation levels of 60 millirem per hour at the surface of the pool water were found, indicative of a leak of one or more of the 252 Cs-137 source capsules used at the irradiator. A summary of the Incident Evaluation Task Force's First Interim Report has been prepared for person's needing an overview of the incident and lessons learned to date. This report provides a summary of Agreement States' views and recommendations on some of the issues raised by the incident

  14. A mirror for lab-based quasi-monochromatic parallel x-rays.

    Science.gov (United States)

    Nguyen, Thanhhai; Lu, Xun; Lee, Chang Jun; Jung, Jin-Ho; Jin, Gye-Hwan; Kim, Sung Youb; Jeon, Insu

    2014-09-01

    A multilayered parabolic mirror with six W/Al bilayers was designed and fabricated to generate monochromatic parallel x-rays using a lab-based x-ray source. Using this mirror, curved bright bands were obtained in x-ray images as reflected x-rays. The parallelism of the reflected x-rays was investigated using the shape of the bands. The intensity and monochromatic characteristics of the reflected x-rays were evaluated through measurements of the x-ray spectra in the band. High intensity, nearly monochromatic, and parallel x-rays, which can be used for high resolution x-ray microscopes and local radiation therapy systems, were obtained.

  15. Recommendations for Nuclear Medicine Technologists Drawn from an Analysis of Errors Reported in Australian Radiation Incident Registers.

    Science.gov (United States)

    Kearney, Nicole; Denham, Gary

    2016-12-01

    When a radiation incident occurs in nuclear medicine in Australia, the incident is reported to the relevant state or territory authority, which performs an investigation and sends its findings to the Australian Radiation Protection and Nuclear Safety Agency. The agency then includes these data in its Australian Radiation Incident Register and makes them available to the public as an annual summary report on its website. The aim of this study was to analyze the radiation incidents included in these annual reports and in the publically available state and territory registers, identify any recurring themes, and make recommendations to minimize future incidents. A multidisciplinary team comprising a nuclear medicine technologist, a radiation therapist, and a diagnostic radiographer analyzed all nuclear medicine technology-, radiation therapy-, and diagnostic radiography-related incidents recorded in the Australian Radiation Incident Register and in the registers of New South Wales, Western Australia, Victoria, South Australia, and Tasmania between 2003 and 2015. Each incident was placed into 1 of 18 categories, and each category was examined to determine any recurring causes of the incidents. We analyzed 209 nuclear medicine incidents. Their primary cause was failure to comply with time-out protocols (85.6%). By analyzing both the causes and the rates of radiation incidents, we were able to recommend ways to help prevent them from being repeated. Information drawn from the Australian Radiation Incident Register and 5 state registers has revealed steps that can be taken by any nuclear medicine department to prevent repetition of the incidents that have already occurred. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  16. The Influence of the Solar Coronal Radiation on Coronal Plasma Structures, I: Determination of the Incident Coronal Radiation

    Science.gov (United States)

    Brown, Gerrard M.; Labrosse, Nicolas

    2018-02-01

    Coronal structures receive radiation not only from the solar disc, but also from the corona. This height-dependent incident radiation plays a crucial role in the excitation and the ionisation of the illuminated plasma. The aim of this article is to present a method for computing the detailed incident radiation coming from the solar corona, which is perceived at a point located at an arbitrary height. The coronal radiation is calculated by integrating the radiation received at a point in the corona over all of the corona visible from this point. The emission from the corona at all wavelengths of interest is computed using atomic data provided by CHIANTI. We obtain the spectrum illuminating points located at varying heights in the corona at wavelengths between 100 and 912 Å when photons can ionise H or He atoms and ions in their ground states. As expected, individual spectral lines will contribute most at the height within the corona where the local temperature is closest to their formation temperature. As there are many spectral lines produced by many ions, the coronal intensity cannot be assumed to vary in the same way at all wavelengths and so must be calculated for each separate height that is to be considered. This code can be used to compute the spectrum from the corona illuminating a point at any given height above the solar surface. This brings a necessary improvement to models where an accurate determination of the excitation and ionisation states of coronal plasma structures is crucial.

  17. SU-E-T-524: Web-Based Radiation Oncology Incident Reporting and Learning System (ROIRLS)

    Energy Technology Data Exchange (ETDEWEB)

    Kapoor, R; Palta, J; Hagan, M [Virginia Commonwealth University, Richmond, VA (United States); National Radiation Oncology Program (10P4H), Richmond, VA (United States); Grover, S; Malik, G [TSG Innovations Inc., Richmond, VA (United States)

    2014-06-01

    Purpose: Describe a Web-based Radiation Oncology Incident Reporting and Learning system that has the potential to improve quality of care for radiation therapy patients. This system is an important facet of continuing effort by our community to maintain and improve safety of radiotherapy.Material and Methods: The VA National Radiation Oncology Program office has embarked on a program to electronically collect adverse events and near miss data of radiation treatment of over 25,000 veterans treated with radiotherapy annually. Software used for this program is deployed on the VAs intranet as a Website. All data entry forms (adverse event or near miss reports, work product reports) utilize standard causal, RT process step taxonomies and data dictionaries defined in AAPM and ASTRO reports on error reporting (AAPM Work Group Report on Prevention of Errors and ASTROs safety is no accident report). All reported incidents are investigated by the radiation oncology domain experts. This system encompasses the entire feedback loop of reporting an incident, analyzing it for salient details, and developing interventions to prevent it from happening again. The operational workflow is similar to that of the Aviation Safety Reporting System. This system is also synergistic with ROSIS and SAFRON. Results: The ROIRLS facilitates the collection of data that help in tracking adverse events and near misses and develop new interventions to prevent such incidents. The ROIRLS electronic infrastructure is fully integrated with each registered facility profile data thus minimizing key strokes and multiple entries by the event reporters. Conclusions: OIRLS is expected to improve the quality and safety of a broad spectrum of radiation therapy patients treated in the VA and fulfills our goal of Effecting Quality While Treating Safely The Radiation Oncology Incident Reporting and Learning System software used for this program has been developed, conceptualized and maintained by TSG Innovations

  18. SU-E-T-524: Web-Based Radiation Oncology Incident Reporting and Learning System (ROIRLS)

    International Nuclear Information System (INIS)

    Kapoor, R; Palta, J; Hagan, M; Grover, S; Malik, G

    2014-01-01

    Purpose: Describe a Web-based Radiation Oncology Incident Reporting and Learning system that has the potential to improve quality of care for radiation therapy patients. This system is an important facet of continuing effort by our community to maintain and improve safety of radiotherapy.Material and Methods: The VA National Radiation Oncology Program office has embarked on a program to electronically collect adverse events and near miss data of radiation treatment of over 25,000 veterans treated with radiotherapy annually. Software used for this program is deployed on the VAs intranet as a Website. All data entry forms (adverse event or near miss reports, work product reports) utilize standard causal, RT process step taxonomies and data dictionaries defined in AAPM and ASTRO reports on error reporting (AAPM Work Group Report on Prevention of Errors and ASTROs safety is no accident report). All reported incidents are investigated by the radiation oncology domain experts. This system encompasses the entire feedback loop of reporting an incident, analyzing it for salient details, and developing interventions to prevent it from happening again. The operational workflow is similar to that of the Aviation Safety Reporting System. This system is also synergistic with ROSIS and SAFRON. Results: The ROIRLS facilitates the collection of data that help in tracking adverse events and near misses and develop new interventions to prevent such incidents. The ROIRLS electronic infrastructure is fully integrated with each registered facility profile data thus minimizing key strokes and multiple entries by the event reporters. Conclusions: OIRLS is expected to improve the quality and safety of a broad spectrum of radiation therapy patients treated in the VA and fulfills our goal of Effecting Quality While Treating Safely The Radiation Oncology Incident Reporting and Learning System software used for this program has been developed, conceptualized and maintained by TSG Innovations

  19. Monochromatic Electromagnetic Wavelets and the Huygens Principle

    Science.gov (United States)

    Sheng, Yunlong; Deschênes, Sylvain; Caulfield, H. John

    1998-02-01

    For the first time, to our knowledge, optical diffraction is shown to be a wavelet transform with the electromagnetic wavelets. We show that the optical wavelets proposed by Onural Opt. Lett. 18, 846 (1993) are the Huygens wavelets under a Fresnel approximation, and the electromagnetic wavelets proposed by Kaiser A Friendly Guide to Wavelets (Birkhauser, Boston, Mass., 1994) reduce to Hyugens wavelets in the case of a monochromatic field.

  20. Female all cancer incidence in medical radiation workers in Latvia 1982-2002

    International Nuclear Information System (INIS)

    Matisane, L.; Carpenter, L.; Venables, K.

    2005-01-01

    Medical radiation workers belong to one of the oldest occupational groups exposed to external radiation. Since the various radiological protection recommendations have been introduced, now ths process has resulted in low-dose exposure, regular monitoring of exposure and establishment of national dose registration bodies. In order to provide additional information to studies on cancer incidence among medical radiation workers (specially female workers) and in order to assess all cancer incidence in female medical radiation workers in Latvia, a retrospective cohort study based on the National Dose Register was set up in Latvia. The study cohort consisted of all workers employed in health care, occupationally exposed to ionising radiation for more than one year in any of the public health care establishments in Latvia, except military ones, between 1 January 1972 and 1 January 2002 and who were registered in the National Dose Register of Latvia. The cohort consisted of 1416 female medical radiation workers either in hospitals or outpatient departments, or both. The cohort included diagnostic and therapeutic radiologists with predominantly medical qualification, it also included radiotechnologits, nurses, junior nurses, but it did not include academic, physicists and dentists. In all cases the calculated SIR was over than expected or close to expected. Several major differences in study design makes ir difficult to compare the results of this study with the results of the studies carried out in other countries

  1. Incidence of Second Malignancies Among Patients Treated With Proton Versus Photon Radiation

    International Nuclear Information System (INIS)

    Chung, Christine S.; Yock, Torunn I.; Nelson, Kerrie; Xu, Yang; Keating, Nancy L.; Tarbell, Nancy J.

    2013-01-01

    Purpose: Proton radiation, when compared with photon radiation, allows delivery of increased radiation dose to the tumor while decreasing dose to adjacent critical structures. Given the recent expansion of proton facilities in the United States, the long-term sequelae of proton therapy should be carefully assessed. The objective of this study was to compare the incidence of second cancers in patients treated with proton radiation with a population-based cohort of matched patients treated with photon radiation. Methods and Materials: We performed a retrospective cohort study of 558 patients treated with proton radiation from 1973 to 2001 at the Harvard Cyclotron in Cambridge, MA and 558 matched patients treated with photon therapy in the Surveillance, Epidemiology, and End Results (SEER) Program cancer registry. Patients were matched by age at radiation treatment, sex, year of treatment, cancer histology, and site. The main outcome measure was the incidence of second malignancies after radiation. Results: We matched 558 proton patients with 558 photon patients from the Surveillance, Epidemiology, and End Results registry. The median duration of follow-up was 6.7 years (interquartile range, 7.4) and 6.0 years (interquartile range, 9.3) in the proton and photon cohorts, respectively. The median age at treatment was 59 years in each cohort. Second malignancies occurred in 29 proton patients (5.2%) and 42 photon patients (7.5%). After we adjusted for sex, age at treatment, primary site, and year of diagnosis, proton therapy was not associated with an increased risk of second malignancy (adjusted hazard ratio, 0.52 [95% confidence interval, 0.32-0.85]; P=.009). Conclusions: The use of proton radiation therapy was not associated with a significantly increased risk of secondary malignancies compared with photon therapy. Longer follow-up of these patients is needed to determine if there is a significant decrease in second malignancies. Given the limitations of the study

  2. Factors influencing the incidence of sinusitis in nasopharyngeal carcinoma patients after intensity-modulated radiation therapy.

    Science.gov (United States)

    Su, Yan-xia; Liu, Lan-ping; Li, Lei; Li, Xu; Cao, Xiu-juan; Dong, Wei; Yang, Xin-hua; Xu, Jin; Yu, Shui; Hao, Jun-fang

    2014-12-01

    The aim of the study was to investigate the incidence of sinusitis in nasopharyngeal carcinoma (NPC) patients before and after intensity-modulated radiation therapy (IMRT) and to analyze factors associated with the incidence of sinusitis following IMRT. We retrospectively analyzed 283 NPC patients who received IMRT in our hospital from March 2009 to May 2011. The diagnostic criteria for sinusitis are based on computed tomography (CT) or magnetic resonance imaging (MRI) findings. CT or MRI scans were performed before and after IMRT to evaluate the incidence of sinusitis. Factors influencing the incidence of sinusitis were analyzed by log-rank univariate and logistic multivariate analyses. Among the 283 NPC patients, 128 (45.2 %) suffered from sinusitis before radiotherapy. The incidence rates of sinusitis in patients with T1, T2, T3, and T4 NPC before radiotherapy were 22.6, 37.5, 46.8, and 61.3 %, respectively (χ 2 = 14.548, p = 0.002). Among the 155 NPC patients without sinusitis before radiotherapy, the incidence rates of sinusitis at the end of radiotherapy and at 1, 3, 6, 9, 12, and 18 months after radiotherapy were 32.9, 43.2, 61.3, 68.4, 73.5, 69.7, and 61.3 %, respectively (χ 2 = 86.461, p < 0.001). Univariate analysis showed that T stage, invasion of the nasal cavity, nasal irrigation, and radiation dose to the nasopharynx were associated with the incidence of sinusitis in NPC patients after IMRT (p = 0.003, 0.006, 0.002, and 0.020). Multivariate analysis showed that T stage, invasion of the nasal cavity, and nasal irrigation were influential factors for the incidence of sinusitis in NPC patients after IMRT (p = 0.002, 0.002, and 0.000). There was a higher incidence of sinusitis with higher T stage among NPC patients before radiotherapy, and the incidence of sinusitis in NPC patients after IMRT was high (45.2 %). The incidence of sinusitis increased rapidly within the first 3 months after IMRT, and the number of sinusitis cases peaked at 6-9 months after

  3. Radiation protection measures in the case of incidents and radiation accidents

    International Nuclear Information System (INIS)

    Herzberg, B.

    1976-01-01

    Measures to be taken in the case of radiation accidents connected with an unusually high radiation exposure to persons, the amounts of which exceed the limiting values, with depend on whether there has been an external or an internal exposure. In order to give further treatment in the case of whole-body or partial-body irradiation, it is necessary to estimate the exposure dose. In nuclear medicine the accident doses are generally low, i.e. acute radiation damage does not occur here, and immediate measures are not necessary. Therapeutic measures in the case of incorporation accidents are only necessary when the maximum amounts for the nuclide in question recommended by the ICRP has been reached or exceeded in the organism. However, decorporation measures ought to be carried out only by qualified radiation protection physicians. The type of radiation accident which occurs most frequently in nuclear medicine is radiation exposure as a result of contamination. If in the case of contamination of a person the measurement exceeds the radioactivity limit, the decontamination measures are necessary. In the present contribution, these measures for cases without injuries are described in detail. (orig./HP) [de

  4. Ischemic heart disease in workers at Mayak PA: latency of incidence risk after radiation exposure.

    Directory of Open Access Journals (Sweden)

    Cristoforo Simonetto

    Full Text Available We present an updated analysis of incidence and mortality from atherosclerotic induced ischemic heart diseases in the cohort of workers at the Mayak Production Association (PA. This cohort constitutes one of the most important sources for the assessment of radiation risk. It is exceptional because it comprises information on several other risk factors. While most of the workers have been exposed to external gamma radiation, a large proportion has additionally been exposed to internal radiation from inhaled plutonium. Compared to a previous study by Azizova et al. 2012, the updated dosimetry system MWDS-2008 has been applied and methods of analysis have been revised. We extend the analysis of the significant incidence risk and observe that main detrimental effects of external radiation exposure occur after more than about 30 years. For mortality, significant risk was found in males with an excess relative risk per dose of 0.09 (95% CI: 0.02; 0.16 [Formula: see text] while risk was insignificant for females. With respect to internal radiation exposure no association to risk could be established.

  5. Continuous variable entanglement by radiation pressure

    Energy Technology Data Exchange (ETDEWEB)

    Pirandola, Stefano; Mancini, Stefano; Vitali, David; Tombesi, Paolo [INFM, Dipartimento di Fisica, Universita di Camerino, I-62032 Camerino (Italy)

    2003-08-01

    We show that when an intense and quasi-monochromatic laser field is incident on a single vibrating and perfectly reflecting mirror in free space, radiation pressure realizes an effective coupling between a mirror vibrational mode and the first two optical sidebands of the incident field. The two reflected sidebands are in fact entangled by the optomechanical interaction and the resulting continuous variable entanglement proves to be robust against the thermal noise acting on the vibrational mode. If the duration of the incident laser pulse is appropriately chosen, the resulting state of the two sideband modes becomes an exact two-mode squeezed state.

  6. Radiating low back pain in general practice : Incidence, prevalence, diagnosis, and long-term clinical course of illness

    NARCIS (Netherlands)

    Spijker-Huiges, Antje; Groenhof, Feikje; Winters, Jan C.; van Wijhe, Marten; Groenier, Klaas H.; van der Meer, Klaas

    Objective. The aim of this study was to calculate the incidence and prevalence of radiating low back pain, to explore the long-term clinical course of radiating low back pain including the influence of radiculopathy (in a subsample of the study population) and non-radiating low back pain thereon,

  7. Radiation risk factors in incidence anortality among exposed individuals of East Kazakhstand m

    Directory of Open Access Journals (Sweden)

    Kazbek Apsalikov

    2014-01-01

    Full Text Available Introduction: Lengthy clinical and epidemiological studies at the Research Institute of Radiation Medicine and Ecology have discovered basic patterns of long-term effects from ionizing radiation in population groups exposed to radiation risk. Methodology for calculating injury from radiation risk factors has been developed and implemented to minimize the effects of the Semipalatinsk nuclear test site (SNTS. Material and methods: We analyzed materials from the database of the Scientific Medical Register that were exposed to radiation as a result of SNTS. We analyzed both male and female populations of the Abay, Beskaragai and Zhanasemei, Kokpekti (control areas of East-Kazakhstan region (EKR from 2008-2012. These populations were split into three groups allocated by the generation. The first group represented persons born from the period of 01/01/1930 -08/01/1949 and their children born from the period of 10/09/1949-12/31/1962. The second group were persons born after 01/01/1963. The third group served as the control and were persons who immigrated to these areas after 1990. Results: There was an increased incidence of cancer (21.5%, p < 0.000734, cardiovascular diseases (10.2%; respiratory problems (9.6%, gastrointestinal issues (9.1%, p < 0.00371-0.00679 in the first group. The effect of the radiation dose has not been fully stuided among the subjects in the second group.The major causes of excess mortality in the first group were neoplams (30.6%, hypertension (23.8%, and myocardial infarction (22.6%. The effects of radiation influenced mortality in the second group were 2-2.5 times lower than the first group.Conclusion: There is a correlation between the size of the radiation dose, the risk profile, and age at the moment of radiation exposure with trends of morbidity and mortality in the radiation exposed areas.

  8. Has the incidence of radiation-induced bowel damage following treatment of uterine carcinoma changed in the last 20 years

    International Nuclear Information System (INIS)

    Allen-Mersh, T.C.; Wilson, E.J.; Hope-Stone, H.F.; Mann, C.V.

    1986-01-01

    Radiation-induced bowel damage occurred in 4.3% of patients treated primarily by irradiation for uterine carcinoma during the period 1962-1982. There has been a progressive rise in the incidence of radiation damage and radiation-induced rectovaginal fistula during this 20-year period. Radiation from intracavitary sources was a contributory factor in 92% of injured cases. The rising incidence of bowel damage in our patients may be due to an increase in the number of patients receiving a high rectal dose from the intracavitary source. There was a significantly (P<0.01) higher incidence of radiation injury in cases of cervical carcinoma compared to endometrical carcinoma. This was because cervical carcinoma tended to present at a more advanced stage than endometrial carcinoma and was more frequently treated with combined external and intracavitary irradiation. There was no significant increase in the incidence of complications among patients undergoing hysterectomy. (author)

  9. Handbook of Monochromatic XPS Spectra, Semiconductors

    Science.gov (United States)

    Crist, B. Vincent

    2000-10-01

    This handbook is one of three containing an invaluable collection of research grade XPS Spectra. Each handbook concentrates on a specific family of materials (the elements and their native oxides, semiconductors and polymers) and is entirely self-contained. The introductory section to each handbook includes comprehensive information about the XPS instrument used, the materials and the advanced methods used to collect the spectra. Energy resolution settings, instrument characteristics, energy referencing methods, traceability, energy scale calibration details and transmission function are all reported. Among the many valuable features included in each of these handbooks are: ? All spectra were measured by using AlK monochromatic X-rays ? All spectra were collected in a self-consistent manner to maximise data reliability and quality ? All peaks in the wide spectra are fully annotated and accompanied by detailed atom % tables that report BEs for each of the labelled peaks ? Each high-energy resolution spectrum is peak-fitted and accompanied by detailed tables containing binding energies, FWHMs and relative percentages. In this volume 'Semiconductors' are contained XPS Spectra from a wide range of semiconductive materials and related materials, a rare tool for scientists and analysts in this area. Exclusive features of this volume include: ? Binding energies are accurate to +/- 0.08eV ? Charge compensation was done with a flood-gun mesh-screen system ? Valence band spectra document the occupied density of states (DOS) and the fundamental electronic nature of the semi-conductive materials analysed ? Analyses were done: "as received", "freshly fractured in air", "ion etched" and "chemically treated" ? Alphabetically organised by chemical abbreviations for ease of locating each material This handbook is an invaluable reference for materials scientists and electrical engineers in industry, academia and government laboratories interested in the analysis of semiconductors

  10. Medical and policy considerations for nuclear and radiation accidents, incidents and terrorism.

    Science.gov (United States)

    Gale, Robert Peter

    2017-11-01

    The purpose of this review is to address the increasing medical and public concern regarding the health consequences of radiation exposure, a concern shaped not only by fear of another Chernobyl or Fukushima nuclear power facility accident but also by the intentional use of a nuclear weapon, a radiological dispersion device, a radiological exposure device, or an improved nuclear device by rogue states such as North Korea and terrorist organizations such as Al Qaeda and ISIS. The United States has the medical capacity to respond to a limited nuclear or radiation accident or incident but an effective medical response to a catastrophic nuclear event is impossible. Dealing effectively with nuclear and radiation accidents or incidents requires diverse strategies, including policy decisions, public education, and medical preparedness. I review medical consequences of exposures to ionizing radiations, likely concomitant injuries and potential medical intervention. These data should help haematologists and other healthcare professionals understand the principles of medical consequences of nuclear terrorism. However, the best strategy is prevention.

  11. A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination

    International Nuclear Information System (INIS)

    Jeung, Seung Woon; Lim, Cheong Hwan; Jung, Hong Ryang; Joo, Yeong Cheol; Park, Mi Ja; Han, Beon Hee

    2012-01-01

    cervical vertebra, OID, axis angle, and FID, all of them were shown to have correlations with the incidence angle (p<.01). Conclusively, it was shown that the incidence angle was measured differently from average length of cervical vertebra, OID, FID, and axis slope, as well as from age and sex. Therefore, it can be suggested that the anteroposterior radiation test for cervical vertebra should be conducted by different incidence angles based on age and sex. The data of this study may be used as reference in determining the incidence angle of cervical vertebra tests for the future.

  12. A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination

    Energy Technology Data Exchange (ETDEWEB)

    Jeung, Seung Woon; Lim, Cheong Hwan; Jung, Hong Ryang; Joo, Yeong Cheol; Park, Mi Ja [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of); Han, Beon Hee [Dept. of Radiological Science, Seonam University, Namwon (Korea, Republic of)

    2012-06-15

    of cervical vertebra, OID, axis angle, and FID, all of them were shown to have correlations with the incidence angle (p<.01). Conclusively, it was shown that the incidence angle was measured differently from average length of cervical vertebra, OID, FID, and axis slope, as well as from age and sex. Therefore, it can be suggested that the anteroposterior radiation test for cervical vertebra should be conducted by different incidence angles based on age and sex. The data of this study may be used as reference in determining the incidence angle of cervical vertebra tests for the future.

  13. Analysis of monochromatic signals by using data from the detector of Allegro gravitational waves

    International Nuclear Information System (INIS)

    Oliveira, Fernanda Gomes de

    2010-01-01

    The present work is developed in the searching for monochromatic gravitational waves signals in ALLEGRO's data. We have two procedures for data analysis based on the periodogram of Welch, which a method for the detection of monochromatic signals in the middle of noise which basically makes power spectrum estimates using averaged modified periodograms. By using this method it was possible to obtain a power spectrum for the data which reinforce peaks due to monochromatic signals. The two procedures of analysis for the years 1997 and 1999, were focused on monitoring a peak that appears in the spectral density of ALLEGRO's detector, so called 'mystery mode' (near 887 Hz). We look for variations in the frequency of the mystery mode that agree with the variation of the Doppler effect. In the rst analysis we have used by the variation of daily and annual Doppler shift. For the second one, we have only searched annual Doppler shift. We have applied the periodogram of Welch in both tests in the raw data of the detector in the search for a real signal and we found some peaks that can be candidates of gravitational radiation only the second analysis. In order to test the method we used in both analysis a simulated gravitational wave signal modulated by the Doppler effect injected in the data. We detected in both methods the artificial signal of GW simulated. Therefore we have reason to conclude that both methods are efficient in the search for monochromatic signals. (author)

  14. An Evaluation of Departmental Radiation Oncology Incident Reports: Anticipating a National Reporting System

    International Nuclear Information System (INIS)

    Terezakis, Stephanie A.; Harris, Kendra M.; Ford, Eric; Michalski, Jeff; DeWeese, Theodore; Santanam, Lakshmi; Mutic, Sasa; Gay, Hiram

    2013-01-01

    Purpose: Systems to ensure patient safety are of critical importance. The electronic incident reporting systems (IRS) of 2 large academic radiation oncology departments were evaluated for events that may be suitable for submission to a national reporting system (NRS). Methods and Materials: All events recorded in the combined IRS were evaluated from 2007 through 2010. Incidents were graded for potential severity using the validated French Nuclear Safety Authority (ASN) 5-point scale. These incidents were categorized into 7 groups: (1) human error, (2) software error, (3) hardware error, (4) error in communication between 2 humans, (5) error at the human-software interface, (6) error at the software-hardware interface, and (7) error at the human-hardware interface. Results: Between the 2 systems, 4407 incidents were reported. Of these events, 1507 (34%) were considered to have the potential for clinical consequences. Of these 1507 events, 149 (10%) were rated as having a potential severity of ≥2. Of these 149 events, the committee determined that 79 (53%) of these events would be submittable to a NRS of which the majority was related to human error or to the human-software interface. Conclusions: A significant number of incidents were identified in this analysis. The majority of events in this study were related to human error and to the human-software interface, further supporting the need for a NRS to facilitate field-wide learning and system improvement

  15. An Evaluation of Departmental Radiation Oncology Incident Reports: Anticipating a National Reporting System

    Energy Technology Data Exchange (ETDEWEB)

    Terezakis, Stephanie A., E-mail: stereza1@jhmi.edu [Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Harris, Kendra M. [Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Ford, Eric [Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Michalski, Jeff [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri (United States); DeWeese, Theodore [Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Santanam, Lakshmi; Mutic, Sasa; Gay, Hiram [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri (United States)

    2013-03-15

    Purpose: Systems to ensure patient safety are of critical importance. The electronic incident reporting systems (IRS) of 2 large academic radiation oncology departments were evaluated for events that may be suitable for submission to a national reporting system (NRS). Methods and Materials: All events recorded in the combined IRS were evaluated from 2007 through 2010. Incidents were graded for potential severity using the validated French Nuclear Safety Authority (ASN) 5-point scale. These incidents were categorized into 7 groups: (1) human error, (2) software error, (3) hardware error, (4) error in communication between 2 humans, (5) error at the human-software interface, (6) error at the software-hardware interface, and (7) error at the human-hardware interface. Results: Between the 2 systems, 4407 incidents were reported. Of these events, 1507 (34%) were considered to have the potential for clinical consequences. Of these 1507 events, 149 (10%) were rated as having a potential severity of ≥2. Of these 149 events, the committee determined that 79 (53%) of these events would be submittable to a NRS of which the majority was related to human error or to the human-software interface. Conclusions: A significant number of incidents were identified in this analysis. The majority of events in this study were related to human error and to the human-software interface, further supporting the need for a NRS to facilitate field-wide learning and system improvement.

  16. Incident learning and failure-mode-and-effects-analysis guided safety initiatives in radiation medicine

    Directory of Open Access Journals (Sweden)

    Ajay eKapur

    2013-12-01

    Full Text Available By combining incident learning and process failure-mode-and-effects-analysis in a structure-process-outcome framework we have created a risk profile for our radiation medicine practice and implemented evidence-based risk mitigation initiatives focused on patient safety. Based on reactive reviews of incidents reported in our departmental incident-reporting system and proactive failure-mode-and-effects-analysis, high safety-risk procedures in our paperless radiation medicine process and latent risk factors were identified. Six initiatives aimed at the mitigation of associated severity, likelihood of occurrence and detectability risks were implemented. These were the standardization of care pathways and toxicity grading, pre-treatment-planning peer review, a policy to thwart delay-rushed processes, an electronic whiteboard to enhance coordination and the use of six-sigma metrics to monitor operational efficiencies. The effectiveness of these initiatives over a three year period was assessed using process and outcome specific metrics within the framework of the department structure. There has been a 47% increase in incident reporting, with no increase in adverse events. Care pathways have been used with greater than 97% clinical compliance rate. The implementation of peer review prior to treatment planning and use of the whiteboard have provided opportunities for proactive detection and correction of errors. There has been a twofold drop in the occurrence of high-risk procedural delays. Patient treatment start delays are routinely enforced on cases that would have historically been rushed. Z-scores for high risk procedures have steadily improved from 1.78 to 2.35. The initiatives resulted in sustained reductions of failure-mode risks as measured by a set of evidence-based metrics over a three year period. These augment or incorporate many of the published recommendations for patient safety in radiation medicine by translating them to clinical

  17. Incidence of neural tube defects in the natural radiation coastal areas of Kerala

    International Nuclear Information System (INIS)

    Jaikrishan, G.; Sudheer, K.R.; Andrews, V.J.; Koya, P.K.M.; Cheriyan, V.D.; Seshadri, M.

    2010-01-01

    All consecutive births in selected government hospitals in and around the high level natural background radiation areas (HLNRA) of Kerala were monitored for congenital malformations observable at birth since 1995. The HLNR area, a coastal strip of land about 55 km in length and 0.5 km in breadth from Purakkad in the north in Alleppey district to Sakthikulangara in the south of Quilon district, stands out among the most prominent background radiation areas of the world. Natural deposit of monazite sand, containing Thorium (8-10%), Uranium (0.3%) and corresponding decay products, is the source of elevated background radiation, ranging from < 1 to 45 mGy/year. Wide variation in dose, due to the patchy and non-uniform distribution of Monazite sand, enables in built controls. High population density, limited migration, ethnic diversity, good literacy, health awareness, institutionalized births and acceptance of small family norm are some of the key features of the population. Areas with a mean radiation dose of more than 1.5 mGy/year were treated as HLNR areas and areas with a dose level of 1.5 mGy/year or less were treated as normal level radiation (NLNR) areas. The study carried out since 1995 does not seem to implicate HLNR in the incidence of neural tube defects among newborns

  18. Incidence and predictors of Lhermitte’s sign among patients receiving mediastinal radiation for lymphoma

    International Nuclear Information System (INIS)

    Youssef, Bassem; Shank, JoAnn; Reddy, Jay P.; Pinnix, Chelsea C.; Farha, George; Akhtari, Mani; Allen, Pamela K.; Fanale, Michelle A.; Garcia, John A.; Horace, Patricia H.; Milgrom, Sarah; Smith, Grace Li; Nieto, Yago; Arzu, Isadora; Wang, He; Fowler, Nathan; Rodriguez, Maria Alma; Dabaja, Bouthaina

    2015-01-01

    To prospectively examine the risk of developing Lhermitte’s sign (LS) in patients with lymphoma treated with modern-era chemotherapy followed by consolidation intensity-modulated radiation therapy. We prospectively interviewed all patients with lymphoma who received irradiation to the mediastinum from July 2011 through April 2014. We extracted patient, disease, and treatment-related variables from the medical records of those patients and dosimetric variables from treatment-planning systems and analyzed these factors to identify potential predictors of LS with Pearson chi-square tests. During the study period 106 patients received mediastinal radiation for lymphoma, and 31 (29 %) developed LS. No correlations were found between LS and any of the variables examined, including total radiation dose, maximum point dose to the spinal cord, volume receiving 105 % of the dose, and volumes receiving 5 or 15 Gy. In this group of patients, treatment with chemotherapy followed by intensity-modulated radiation therapy led to 29 % developing LS; this symptom was independent of radiation dose and seemed to be an idiosyncratic reaction. This relatively high incidence could have resulted from prospective use of a structured interview

  19. Incidence and predictors of Lhermitte's sign among patients receiving mediastinal radiation for lymphoma.

    Science.gov (United States)

    Youssef, Bassem; Shank, JoAnn; Reddy, Jay P; Pinnix, Chelsea C; Farha, George; Akhtari, Mani; Allen, Pamela K; Fanale, Michelle A; Garcia, John A; Horace, Patricia H; Milgrom, Sarah; Smith, Grace Li; Nieto, Yago; Arzu, Isadora; Wang, He; Fowler, Nathan; Rodriguez, Maria Alma; Dabaja, Bouthaina

    2015-09-25

    To prospectively examine the risk of developing Lhermitte's sign (LS) in patients with lymphoma treated with modern-era chemotherapy followed by consolidation intensity-modulated radiation therapy. We prospectively interviewed all patients with lymphoma who received irradiation to the mediastinum from July 2011 through April 2014. We extracted patient, disease, and treatment-related variables from the medical records of those patients and dosimetric variables from treatment-planning systems and analyzed these factors to identify potential predictors of LS with Pearson chi-square tests. During the study period 106 patients received mediastinal radiation for lymphoma, and 31 (29 %) developed LS. No correlations were found between LS and any of the variables examined, including total radiation dose, maximum point dose to the spinal cord, volume receiving 105 % of the dose, and volumes receiving 5 or 15 Gy. In this group of patients, treatment with chemotherapy followed by intensity-modulated radiation therapy led to 29 % developing LS; this symptom was independent of radiation dose and seemed to be an idiosyncratic reaction. This relatively high incidence could have resulted from prospective use of a structured interview.

  20. Relation between cancer incidence or mortality and external natural background radiation in Japan

    International Nuclear Information System (INIS)

    Ujeno, Y.

    1983-01-01

    Analysis was performed on the relationships between the organ dose-equivalent rate due to natural background radiation (mSv/a) and three parameters of cancer risk: the age-adjusted cancer incidence (patients x 10 5 persons x a -1 ) in 13 large areas, the standardized mortality ratio of cancers in 46 large areas, and the cancer mortality in the population aged more than 40 years old (cancer deaths x 10 5 persons x a -1 ) in 649 small areas. The age-adjusted liver cancer incidence in males fitted the exponential model significantly (p<0.01) and the relationship of stomach cancer mortality of aged males in small areas fitted the linear model significantly (p<0.05). No relationship was observed with regard to female cancer in either case. The relationships between the three parameters and various other cancers of both sexes were not statistically significant. (author)

  1. Causality of relationship between paternal radiation exposure and leukaemia incidence in the children of Sellafield workers

    International Nuclear Information System (INIS)

    Wheldon, T.E.; Mairs, R.J.; Barrett, A.

    1992-01-01

    In this letter the author comments on K.E. Baverstock's case (1991) against the likelihood of a causal relationship between reported leukemia incidence and paternal radiation dose in the children of Sellafield workers, and emphasizes the desirability of devising experimental tests of the germ-cell line damage hypothesis as well as the evaluation of its plausibility. Particular reference is made to the role played by dose-rates and by the two-hit model for childhood acute leukemia. (Letter to the Editor)

  2. Health status of grandchildren of subjects occupationally exposed to chronic radiation. Communication 3. Disease incidence

    International Nuclear Information System (INIS)

    Petrushkina, N.P.; Musatkova, O.B.

    1996-01-01

    The morbidity of 1557 grandchildren of subjects occupationally exposed to chronic radiation were analyzed. Three groups were singled out. Group 1 consisted of children whose grandfathers were exposed, group 2 of children grandmothers were exposed and group 3 of children whose both grandparent were exposed. Total morbidity level and morbidity structure for 13 classes of diseases and 60 nosological entities was assessed. The study showed that disease incidence in general, structure by disease and individual nosological entities, the share of frequently falling ill children, and health index in the test group corresponded to those in controls. Reliable differences were observed only for respiratory diseases, at the expense of acute respiratory diseases, which were frequent during the second-third years of life in children whose both grandparents were occupationally exposed to radiation [ru

  3. SU-E-T-208: Incidence Cancer Risk From the Radiation Treatment for Acoustic Neuroma Patient

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D [Kyung Hee University International Med. Serv., Seoul (Korea, Republic of); Chung, W [Kyung Hee University Hospital at Gangdong, Seoul, Seoul (Korea, Republic of); Shin, D [Kyung Hee University Hospital, Seoul, Seoul (Korea, Republic of); Yoon, M [Korea University, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: The present study aimed to compare the incidence risk of a secondary cancer from therapeutic doses in patients receiving intensitymodulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). Methods: Four acoustic neuroma patients were treated with IMRT, VMAT, or SRS. Their incidnece excess relative risk (ERR), excess absolute risk (EAR), and lifetime attributable risk (LAR) were estimated using the corresponding therapeutic doses measured at various organs by radio-photoluminescence glass dosimeters (RPLGD) placed inside a humanoid phantom. Results: When a prescription dose was delivered in the planning target volume of the 4 patients, the average organ equivalent doses (OED) at the thyroid, lung, normal liver, colon, bladder, prostate (or ovary), and rectum were measured. The OED decreased as the distance from the primary beam increased. The thyroid received the highest OED compared to other organs. A LAR were estimated that more than 0.03% of AN patients would get radiation-induced cancer. Conclusion: The tyroid was highest radiation-induced cancer risk after radiation treatment for AN. We found that LAR can be increased by the transmitted dose from the primary beam. No modality-specific difference in radiation-induced cancer risk was observed in our study.

  4. Molecular dynamics study of radiation damage and microstructure evolution of zigzag single-walled carbon nanotubes under carbon ion incidence

    Science.gov (United States)

    Li, Huan; Tang, Xiaobin; Chen, Feida; Huang, Hai; Liu, Jian; Chen, Da

    2016-07-01

    The radiation damage and microstructure evolution of different zigzag single-walled carbon nanotubes (SWCNTs) were investigated under incident carbon ion by molecular dynamics (MD) simulations. The radiation damage of SWCNTs under incident carbon ion with energy ranging from 25 eV to 1 keV at 300 K showed many differences at different incident sites, and the defect production increased to the maximum value with the increase in incident ion energy, and slightly decreased but stayed fairly stable within the majority of the energy range. The maximum damage of SWCNTs appeared when the incident ion energy reached 200 eV and the level of damage was directly proportional to incident ion fluence. The radiation damage was also studied at 100 K and 700 K and the defect production decreased distinctly with rising temperature because radiation-induced defects would anneal and recombine by saturating dangling bonds and reconstructing carbon network at the higher temperature. Furthermore, the stability of a large-diameter tube surpassed that of a thin one under the same radiation environments.

  5. Spatial variation of natural radiation and childhood leukaemia incidence in Great Britain

    International Nuclear Information System (INIS)

    Richardson, Sylvia; Monfort, Christine; Green, Martyn; Muirhead, Colin; Draper, Gerald

    1995-01-01

    This paper describes an analysis of the geographical variation of childhood leukaemia incidence in Great Britain over a 15 year period in relation to natural radiation (gamma and radon). Data at the level of the 459 district level local authorities in England, Wales and regional districts in Scotland are analysed in two complementary ways: first, by Poisson regressions with the inclusion of environmental covariates and a smooth spatial structure; secondly, by a hierarchical Bayesian model in which extra-Poisson variability is modelled explicitly in terms of spatial and non-spatial components. From this analysis, we deduce a strong indication that a main part of the variability is accounted for by a local neighbourhood 'clustering' structure. This structure is furthermore relatively stable over the 15 year period for the lymphocytic leukaemias which make up the majority of observed cases. We found no evidence of a positive association of childhood leukaemia incidence with outdoor or indoor gamma radiation levels. There is no consistent evidence of any association with radon levels. Indeed, in the Poisson regressions, a significant positive association was only observed for one 5-year period, a result which is not compatible with a stable environmental effect. Moreover, this positive association became clearly non-significant when over-dispersion relative to the Poisson distribution was taken into account. (author)

  6. Unusual reflection of electromagnetic radiation from a stack of graphene layers at oblique incidence

    International Nuclear Information System (INIS)

    Bludov, Yu V; Peres, N M R; Vasilevskiy, M I

    2013-01-01

    We study the interaction of electromagnetic (EM) radiation with single-layer graphene and a stack of parallel graphene sheets at arbitrary angles of incidence. It is found that the behavior is qualitatively different for transverse magnetic (or p-polarized) and transverse electric (or s-polarized) waves. In particular, the absorbance of single-layer graphene attains a minimum (maximum) for the p (s)-polarization at the angle of total internal reflection when the light comes from a medium with a higher dielectric constant. In the case of equal dielectric constants of the media above and beneath graphene, for grazing incidence graphene is almost 100% transparent to p-polarized waves and acts as a tunable mirror for the s-polarization. These effects are enhanced for a stack of graphene sheets, so the system can work as a broad band polarizer. It is shown further that a periodic stack of graphene layers has the properties of a one-dimensional photonic crystal, with gaps (or stop bands) at certain frequencies. When an incident EM wave is reflected from this photonic crystal, the tunability of the graphene conductivity renders the possibility of controlling the gaps, and the structure can operate as a tunable spectral-selective mirror. (paper)

  7. A management plan for hospitals and medical centers facing radiation incidents.

    Science.gov (United States)

    Davari, Fereshteh; Zahed, Arash

    2015-09-01

    Nowadays, application of nuclear technology in different industries has largely expanded worldwide. Proportionately, the risk of nuclear incidents and the resulting injuries have, therefore, increased in recent years. Preparedness is an important part of the crisis management cycle; therefore efficient preplanning seems crucial to any crisis management plan. Equipped with facilities and experienced personnel, hospitals naturally engage with the response to disasters. The main purpose of our study was to present a practical management pattern for hospitals and medical centers in case they encounter a nuclear emergency. In this descriptive qualitative study, data were collected through experimental observations, sources like Safety manuals released by the International Atomic Energy Agency and interviews with experts to gather their ideas along with Delphi method for polling, and brainstorming. In addition, the 45 experts were interviewed on three targeted using brainstorming and Delphi method. We finally proposed a management plan along with a set of practicality standards for hospitals and medical centers to optimally respond to nuclear medical emergencies when a radiation incident happens nearby. With respect to the great importance of preparedness against nuclear incidents adoption and regular practice of nuclear crisis management codes for hospitals and medical centers seems quite necessary.

  8. A management plan for hospitals and medical centers facing radiation incidents

    Directory of Open Access Journals (Sweden)

    Fereshteh Davari

    2015-01-01

    Full Text Available Background: Nowadays, application of nuclear technology in different industries has largely expanded worldwide. Proportionately, the risk of nuclear incidents and the resulting injuries have, therefore, increased in recent years. Preparedness is an important part of the crisis management cycle; therefore efficient preplanning seems crucial to any crisis management plan. Equipped with facilities and experienced personnel, hospitals naturally engage with the response to disasters. The main purpose of our study was to present a practical management pattern for hospitals and medical centers in case they encounter a nuclear emergency. Materials and Methods: In this descriptive qualitative study, data were collected through experimental observations, sources like Safety manuals released by the International Atomic Energy Agency and interviews with experts to gather their ideas along with Delphi method for polling, and brainstorming. In addition, the 45 experts were interviewed on three targeted using brainstorming and Delphi method. Results: We finally proposed a management plan along with a set of practicality standards for hospitals and medical centers to optimally respond to nuclear medical emergencies when a radiation incident happens nearby. Conclusion: With respect to the great importance of preparedness against nuclear incidents adoption and regular practice of nuclear crisis management codes for hospitals and medical centers seems quite necessary.

  9. Electromagnetic radiation of electrons in periodic structures

    International Nuclear Information System (INIS)

    Potylitsyn, Alexander Petrovich

    2011-01-01

    Periodic magnetic structures (undulators) are widely used in accelerators to generate monochromatic undulator radiation (UR) in the range from far infrared to the hard X-ray region. Another periodic crystalline structure is used to produce quasimonochromatic polarized photon beams via the coherent bremsstrahlung mechanism (CBS). Due to such characteristics as monochromaticity, polarization and adjustability, these types of radiation is of large interest for applied and basic research of accelerator-emitted radiation. The book provides a detailed overview of the fundamental principles behind electromagnetic radiation emitted from accelerated charged particles (e.g. UR, CBS, radiation of fast electrons in Laser flash fields) as well as a unified description of relatively new radiation mechanisms which attracted great interest in recent years. This are the so-called polarization radiation excited by the Coulomb field of incident particles in periodic structures, parametric X-rays, resonant transition radiation and the Smith-Purcell effect. Characteristics of such radiation sources and perspectives of their usage are discussed. The recent experimental results as well as their interpretation are presented. (orig.)

  10. Can Angiotensin-Converting Enzyme Inhibitors Reduce the Incidence, Severity, and Duration of Radiation Proctitis?

    International Nuclear Information System (INIS)

    Alashkham, Abduelmenem; Paterson, Catherine; Rauchhaus, Petra; Nabi, Ghulam

    2016-01-01

    Purpose: To determine whether participants taking angiotensin-converting enzyme inhibitors (ACEIs) and treated with radical radiation therapy with neoadjuvant/adjuvant hormone therapy have less incidence, severity, and duration of radiation proctitis. Methods and Materials: A propensity score analysis of 817 patients who underwent radical radiation therapy with neoadjuvant or adjuvant hormone therapy as primary line management in a cohort study during 2009 to 2013 was conducted. Patients were stratified as follows: group 1, hypertensive patients taking ACEIs (as a study group); group 2, nonhypertensive patients not taking ACEIs; and group 3, hypertensive patients not taking ACEIs (both as control groups). The incidence, severity, and duration of proctitis were the main outcome. χ 2 tests, Mann-Whitney U tests, analysis of variance, risk ratio (RR), confidence interval (CI), Kaplan-Meier plots, and log-rank tests were used. Results: The mean age of the participants was 68.91 years, with a follow-up time of 3.38 years. Based on disease and age-matched comparison, there was a statistically significant difference of proctitis grading between the 3 groups: χ 2 (8, n=308) = 72.52, P<.001. The Mann-Whitney U test indicated that grades of proctitis were significantly lower in hypertensive patients taking ACEIs than in nonhypertensive patients not taking ACEIs and hypertensive patients not taking ACEIs (P<.001). The risk ratio (RR) of proctitis in hypertensive patients taking ACEIs was significantly lower than in hypertensive patients not taking ACEIs (RR 0.40, 95% CI 0.30-0.53, P<.001) and in nonhypertensive patients not taking ACEIs (RR 0.58, 95% CI 0.44-0.77, P<.001). Time to event analysis revealed that hypertensive patients taking ACEIs were significantly different from the control groups (P<.0001). Furthermore, hypertensive patients taking ACEIs had significantly faster resolution of proctitis (P<.0001). Conclusion: Patients who were taking ACEIs were

  11. Can Angiotensin-Converting Enzyme Inhibitors Reduce the Incidence, Severity, and Duration of Radiation Proctitis?

    Energy Technology Data Exchange (ETDEWEB)

    Alashkham, Abduelmenem, E-mail: alashkham@yahoo.com [Academic Section of Urology, Division of Cancer Research, School of Medicine, University of Dundee, Scotland (United Kingdom); Paterson, Catherine [Academic Section of Urology, Division of Cancer Research, School of Medicine, University of Dundee, Scotland (United Kingdom); Rauchhaus, Petra [Tayside Clinical Trials Unit, School of Medicine, University of Dundee, Scotland (United Kingdom); Nabi, Ghulam [Academic Section of Urology, Division of Cancer Research, School of Medicine, University of Dundee, Scotland (United Kingdom)

    2016-01-01

    Purpose: To determine whether participants taking angiotensin-converting enzyme inhibitors (ACEIs) and treated with radical radiation therapy with neoadjuvant/adjuvant hormone therapy have less incidence, severity, and duration of radiation proctitis. Methods and Materials: A propensity score analysis of 817 patients who underwent radical radiation therapy with neoadjuvant or adjuvant hormone therapy as primary line management in a cohort study during 2009 to 2013 was conducted. Patients were stratified as follows: group 1, hypertensive patients taking ACEIs (as a study group); group 2, nonhypertensive patients not taking ACEIs; and group 3, hypertensive patients not taking ACEIs (both as control groups). The incidence, severity, and duration of proctitis were the main outcome. χ{sup 2} tests, Mann-Whitney U tests, analysis of variance, risk ratio (RR), confidence interval (CI), Kaplan-Meier plots, and log-rank tests were used. Results: The mean age of the participants was 68.91 years, with a follow-up time of 3.38 years. Based on disease and age-matched comparison, there was a statistically significant difference of proctitis grading between the 3 groups: χ{sup 2} (8, n=308) = 72.52, P<.001. The Mann-Whitney U test indicated that grades of proctitis were significantly lower in hypertensive patients taking ACEIs than in nonhypertensive patients not taking ACEIs and hypertensive patients not taking ACEIs (P<.001). The risk ratio (RR) of proctitis in hypertensive patients taking ACEIs was significantly lower than in hypertensive patients not taking ACEIs (RR 0.40, 95% CI 0.30-0.53, P<.001) and in nonhypertensive patients not taking ACEIs (RR 0.58, 95% CI 0.44-0.77, P<.001). Time to event analysis revealed that hypertensive patients taking ACEIs were significantly different from the control groups (P<.0001). Furthermore, hypertensive patients taking ACEIs had significantly faster resolution of proctitis (P<.0001). Conclusion: Patients who were taking ACEIs were

  12. Assessment of ionizing radiation as a risk factor for breast cancer incidence in Goiania

    International Nuclear Information System (INIS)

    Lage, Leonardo Bastos

    2016-01-01

    This research aims to evaluate whether exposure to ionizing radiation to which women are subjected can be associated with the incidence of breast cancer in Goiania. The defined study area is the central region of Goiania, or the Sanitary Districts of Campinas-Centro and Sul, in which are the seven major accident sources of contamination with Cesium 137, and also, as shown by previous study, the majority of new cases of breast cancer (60,43 %). We used the geographical division of the city in census tracts and health districts. The data collection was divided in two stages: the first, for the survey of radiometric measurements, and the second, for identifying the addresses of women diagnosed with breast cancer. The radiometric survey occurred between 2010 and 2014, in which was used an environmental gamma radiation mobile measuring system. This system was composed by a high-sensitivity detector coupled to a Global Positioning System (GPS) and a microcomputer. The assembly was installed on a motor vehicle so that the height of the detector is found at one meter from the ground, and programmed to obtain a measurement of the doses absorbed in the air rate each second. The data collected were: doses absorbed in the air rate, geographical coordinates, altitude, date and time of acquisition. From Mobisys software, files were generated and from ArcGIS 10.0 platform, geospatial assessment survey through the elaboration of thematic maps and geospatial analysis statistics. The annual averages of effective doses and collective effective doses were estimated from the rate of doses absorbed in air collected by the system and the resident population in the census tracts. The second stage begun from the data collection at the Registry of Goiania's Population Based Cancer (RCBPGO), in which were identified addresses of women diagnosed with breast cancer between 2001 and 2010. Part of the data was geographically referenced and using census data were estimated and compared the

  13. ESTIMATION OF TOTAL SOLAR RADIATION INCIDENT ON AN INCLINED SURFACE OF A SOUTH-FACING GREENHOUSE ROOF

    Directory of Open Access Journals (Sweden)

    RONOH E.K.

    2017-12-01

    Full Text Available Solar radiation is the driving force for the surface energy balance in buildings such as greenhouses. Greenhouses are generally tilted towards the sun in order to maximize the solar irradiance on the surfaces. Precise computation of the solar radiation received on these surfaces assumes an important role in the energy simulation. It is practical to calculate the total solar irradiance on inclined surfaces based on the solar global and diffuse radiation intensities on horizontal surfaces. This study focused on estimating the total solar radiation incident on inclined greenhouse roof surfaces. In this work, a south-facing thermal box inclined at 26.5° from the horizontal was used for solar radiation measurements. Additionally, recorded solar radiation data were retrieved for the study location and used to develop an empirical correlation. The conversion factors for the beam, the diffuse and the reflected solar radiation components were essential in the prediction of the total solar radiation incident on the tilted surface. The measured solar radiation data were then compared with the simulated data. The model performance was assessed using both graphical and statistical methods. Overall, locally calibrated data led to a satisfactory improvement in estimation of the total solar radiation on an inclined surface.

  14. Sci-Fri AM: Quality, Safety, and Professional Issues 06: An Evaluation of Incident Reporting and Learning using the Canadian National System for Incident Reporting – Radiation Treatment

    International Nuclear Information System (INIS)

    Montgomery, Logan; Kildea, John

    2016-01-01

    We report on the development and clinical deployment of an in-house incident reporting and learning system that implements the taxonomy of the Canadian National System for Incident Reporting – Radiation Treatment (NSIR-RT). In producing our new system, we aimed to: Analyze actual incidents, as well as potentially dangerous latent conditions. Produce recommendations on the NSIR-RT taxonomy. Incorporate features to divide reporting responsibility among clinical staff and expedite incident categorization within the NSIR-RT framework. Share anonymized incident data with the national database. Our multistep incident reporting workflow is focused around an initial report and a detailed follow-up investigation. An investigator, chosen at the time of reporting, is tasked with performing the investigation. The investigation feature is connected to our electronic medical records database to allow automatic field population and quick reference of patient and treatment information. Additional features include a robust visualization suite, as well as the ability to flag incidents for discussion at monthly Risk Management meetings and task ameliorating actions to staff. Our system was deployed into clinical use in January 2016. Over the first three months of use, 45 valid incidents were reported; 31 of which were reported as actual incidents as opposed to near-misses or reportable circumstances. However, we suspect there is ambiguity within our centre in determining the appropriate event type, which may be arising from the taxonomy itself. Preliminary trending analysis aided in revealing workflow issues pertaining to storage of treatment accessories and treatment planning delays. Extensive analysis will be undertaken as more data are accrued.

  15. Vavilov-Cherenkov radiation as a cause of transition radiation anomalous intensity in case of electron grazing incidence on the silver surface

    International Nuclear Information System (INIS)

    Zrelov, V.P.; Ruzicka, J.

    1979-01-01

    On the basis of the Vavilov-Cherenkov effect the anomaly in the transition radiation (TR) spectrum is explained which has been first observed by Boersch for grazing particle incidence on the silver surface. The contribution of the Vavilov-Cherenkov radiation to the angle distribution of photons of the TR is estimated. Special attention is drawn to a possibility of the nonthreshold character of Vavilov-Cherenkov radiation in such a medium as silver, and to a necessity of creating a complete theory of Vavilov-Cherenkov radiation for absorbing media

  16. Solar ultraviolet radiation in Syria measurements and relationship with skin cancer incidence

    International Nuclear Information System (INIS)

    Othman, I; Baydon, S.A.; Dawood, S.

    1994-11-01

    Seasonal variations of solar UVB (285-320) and UVA (320-400) were measured in three sites in Syria (33-37 N sup O) for two years: 1992-1993. UVB measurements were performed using polysulphone films and Robertson-Berger meter, while UVA measurements were done by NVA intensity meter. Two sets of measurements were carried out : - Maximal daily doses three times a week (every other day) - Diurnal variations from sun-rise to sun-set every two hours twice a month (every fortnight). The biological consequences of ultraviolet radiation withreference to some epidemiological data of skin cancer incidence in Syria since 1980 were discussed .(author). 36 refs., 21 figs., 11 tabs

  17. Mirror and grating surface figure requirements for grazing incidence synchrotron radiation beamlines: Power loading effects

    Energy Technology Data Exchange (ETDEWEB)

    Hulbert, S.L.; Sharma, S.

    1987-01-01

    At present, grazing incidence mirrors are used almost exclusively as the first optical element in VUV and soft x-ray synchrotron radiation beamlines. The performance of these mirrors is determined by thermal and mechanical stress-induced figure errors as well as by figure errors remaining from the grinding and polishing process. With the advent of VUV and soft x-ray undulators and wigglers has come a new set of thermal stress problems related to both the magnitude and the spatial distribution of power from these devices. In many cases the power load on the entrance slits and gratings in these beamlines is no longer negligible. The dependence of thermally-induced front-end mirror figure errors on various storage ring and insertion device parameters (especially those at the National Synchrotron Light Source) and the effects of these figure errors on two classes of soft x-ray beamlines are presented.

  18. Determination, through of thermoluminescence dosimetry, of the incident radiation in critical organs, during cephalometric radiographies

    International Nuclear Information System (INIS)

    Hipolito Junior, O. di; Goncalves, N.; Boscolo, F.N.; Montebelo Filho, A.

    1985-01-01

    The object of this paper was to value and to compare the doses of X-ray incident in critical orgas of patient and operator, during cephalometric radiography. Each patient was submited for two radiographics expositions. First of all, they use the followings factors: 85 kVp, 15 mA and 4/10 s of exposition; while of the second radiography the conditions were of 70 kVp, 15 mA and 1.2 s of exposition. The dosimetric method was the thermoluminescent through the LiF-700. Although the cephalometric radiographies showed similars qualities, in bot conditions where the equipment functioned, the situation of high voltage was noted small doses of radiation. (author) [pt

  19. High-flux normal incidence monochromator for circularly polarized synchrotron radiation

    International Nuclear Information System (INIS)

    Schaefers, F.; Peatman, W.; Eyers, A.; Heckenkamp, C.; Schoenhense, G.; Heinzmann, U.

    1986-01-01

    A 6.5-m normal incidence monochromator installed at the storage ring BESSY, which is optimized for a high throughput of circularly polarized off-plane radiation at moderate resolution is described. The monochromator employs two exit slits and is specially designed and used for low-signal experiments such as spin- and angle-resolved photoelectron spectroscopy on solids, adsorbates, free atoms, and molecules. The Monk--Gillieson mounting (plane grating in a convergent light beam) allows for large apertures with relatively little astigmatism. With two gratings, a flux of more than 10 11 photons s -1 bandwidth -1 (0.2--0.5 nm) with a circular polarization of more than 90% in the wavelength range from 35 to 675 nm is achieved

  20. Mark IV 'Grasshopper' grazing incidence mono-chromator for the Canadian Synchrotron Radiation Facility (CSRF)

    International Nuclear Information System (INIS)

    Tan, K.H.; Bancroft, G.M.; Coatsworth, L.L.; Yates, B.W.

    1982-01-01

    The vacuum, mechanical, and optical characteristics of a 'Grasshopper' grazing incidence monochromator for use with a synchrotron radiation source in the 30-300 eV range is described. The monochromator is compatible with ultrahigh vacuum ( -10 Torr throughout), and the motor driven scan mechanism is linear and reliable. The monchromator has been calibrated using several known absorption edges between 36 and 102 eV and a nonlinear least squares fit to the scan equation. These same absorption edges, plus a scan over zero order, show that the present resolution of the monochromator (with 10 and 16 μm exit and entrance slits respectively) is 0.16 A (0.06 eV at the AlLsub(2,3) edge). With 10 μm entrance and exit slits the resolution will be very close to the theoretical Δlambda = 0.083 A

  1. Mitotic effects of monochromatic ultraviolet radiation at 225, 265, and 280 nm on eleven stages of the cell cycle of the grasshopper neuroblast in culture. I. Overall retardation from the stage irradiated to nuclear membrane breakdown

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, J.G.

    1976-10-01

    Neuroblasts of Chortophaga viridifasciata (DeGeer) in culture were exposed to different doses of 225, 265, or 280 nm ultraviolet radiations at 11 different stages and substages of the mitotic cycle and individually selected cells were timed to breakdown of the nuclear membrane. Comparisons of the effectiveness of different wavelengths on the different stages were based on the dose that reduced the cell progression rate to 67 percent of normal (D/sub 67/) and the slope of the regression line, i.e., the control to treated time (C/T) ratio change/erg/mm/sup 2/ at the D/sub 67/ level. Cells of the prereplication period (metaphase + anaphase + early telophase) and the S phase (middle and late telophase + interphase + very early prophase) are equally sensitive to uv and contrast sharply with the much lower sensitivity of those in the postreplication period (early and middle prophase). This can best be interpreted if chromosomal DNA is the chromophore for uv-induced mitotic retardation. Cells in the prereplication period at exposure show no wavelength effect. In the S phase all stages except middle telophase and all stages combined are significantly more sensitive to 265 and 280 nm than to 225 nm. Of the postreplication stages, early prophase is retarded significantly more by 280 than by 225 or 265 nm. The C/T ratio/erg/mm/sup 2/ is greater after exposure to 265 nm at all prereplication and replication stages, but exhibits no consistent wavelength pattern during the postreplication period. Evidence based on the orientation of the neuroblast with respect to the uv-source suggests that the chromophore for mitotic retardation does not reside within the centrosome and related structures, but may be present, at least partly, in the nucleolus.

  2. Mitotic effects of monochromatic ultraviolet radiation at 225, 265, and 280 nm on eleven stages of the cell cycle of the grasshopper neuroblast in culture. I. Overall retardation from the stage irradiated to nuclear membrane breakdown

    International Nuclear Information System (INIS)

    Carlson, J.G.

    1976-01-01

    Neuroblasts of Chortophaga viridifasciata (DeGeer) in culture were exposed to different doses of 225, 265, or 280 nm ultraviolet radiations at 11 different stages and substages of the mitotic cycle and individually selected cells were timed to breakdown of the nuclear membrane. Comparisons of the effectiveness of different wavelengths on the different stages were based on the dose that reduced the cell progression rate to 67 percent of normal (D 67 ) and the slope of the regression line, i.e., the control to treated time (C/T) ratio change/erg/mm 2 at the D 67 level. Cells of the prereplication period (metaphase + anaphase + early telophase) and the S phase (middle and late telophase + interphase + very early prophase) are equally sensitive to uv and contrast sharply with the much lower sensitivity of those in the postreplication period (early and middle prophase). This can best be interpreted if chromosomal DNA is the chromophore for uv-induced mitotic retardation. Cells in the prereplication period at exposure show no wavelength effect. In the S phase all stages except middle telophase and all stages combined are significantly more sensitive to 265 and 280 nm than to 225 nm. Of the postreplication stages, early prophase is retarded significantly more by 280 than by 225 or 265 nm. The C/T ratio/erg/mm 2 is greater after exposure to 265 nm at all prereplication and replication stages, but exhibits no consistent wavelength pattern during the postreplication period. Evidence based on the orientation of the neuroblast with respect to the uv-source suggests that the chromophore for mitotic retardation does not reside within the centrosome and related structures, but may be present, at least partly, in the nucleolus

  3. Infant Brain Tumors: Incidence, Survival, and the Role of Radiation Based on Surveillance, Epidemiology, and End Results (SEER) Data

    International Nuclear Information System (INIS)

    Bishop, Andrew J.; McDonald, Mark W.; Chang, Andrew L.; Esiashvili, Natia

    2012-01-01

    Purpose: To evaluate the incidence of infant brain tumors and survival outcomes by disease and treatment variables. Methods and Materials: The Surveillance, Epidemiology, and End Results (SEER) Program November 2008 submission database provided age-adjusted incidence rates and individual case information for primary brain tumors diagnosed between 1973 and 2006 in infants less than 12 months of age. Results: Between 1973 and 1986, the incidence of infant brain tumors increased from 16 to 40 cases per million (CPM), and from 1986 to 2006, the annual incidence rate averaged 35 CPM. Leading histologies by annual incidence in CPM were gliomas (13.8), medulloblastoma and primitive neuroectodermal tumors (6.6), and ependymomas (3.6). The annual incidence was higher in whites than in blacks (35.0 vs. 21.3 CPM). Infants with low-grade gliomas had the highest observed survival, and those with atypical teratoid rhabdoid tumors (ATRTs) or primary rhabdoid tumors of the brain had the lowest. Between 1979 and 1993, the annual rate of cases treated with radiation within the first 4 months from diagnosis declined from 20.5 CPM to <2 CPM. For infants with medulloblastoma, desmoplastic histology and treatment with both surgery and upfront radiation were associated with improved survival, but on multivariate regression, only combined surgery and radiation remained associated with improved survival, with a hazard ratio for death of 0.17 compared with surgery alone (p = 0.005). For ATRTs, those treated with surgery and upfront radiation had a 12-month survival of 100% compared with 24.4% for those treated with surgery alone (p = 0.016). For ependymomas survival was higher in patients treated in more recent decades (p = 0.001). Conclusion: The incidence of infant brain tumors has been stable since 1986. Survival outcomes varied markedly by histology. For infants with medulloblastoma and ATRTs, improved survival was observed in patients treated with both surgery and early radiation

  4. An evaluation of early countermeasures to reduce the risk of internal radiation exposure after the Fukushima nuclear incident in Japan.

    Science.gov (United States)

    Nomura, Shuhei; Tsubokura, Masaharu; Gilmour, Stuart; Hayano, Ryugo S; Watanabe, Yuni N; Kami, Masahiro; Kanazawa, Yukio; Oikawa, Tomoyoshi

    2016-05-01

    After a radiation-release incident, intake of radionuclides in the initial stage immediately following the incident may be the major contributor to total internal radiation exposure for individuals in affected areas. However, evaluation of early internal contamination risk is greatly lacking. This study assessed the relationship between initial stage evacuation/indoor sheltering and internal radiation contamination levels 4 months after the 2011 Fukushima nuclear incident in Japan and estimated potential pathways of the contamination. The study population comprised 525 participants in the internal radiation screening program at Minamisoma Municipal General Hospital, 23 km north of the Fukushima nuclear plant. The analysed dataset included the results of a screening performed in July 2011, 4 months after the incident, and of a questionnaire on early-incident response behaviours, such as sheltering indoors and evacuations, completed by participants. Association between such early countermeasures and internal contamination levels of cesium-134 were assessed using Tobit multiple regression analyses. Our study shows that individuals who evacuated to areas outside Fukushima Prefecture had similar contamination levels of cesium-134 to individuals who stayed in Fukushima (relative risk: 0.86; 95% confidence interval: 0.74-0.99). Time spent outdoors had no significant relationship with contamination levels. The effects of inhalation from radiological plumes released from the nuclear plant on total internal radiation contamination might be so low as to be undetectable by the whole-body counting unit used to examine participants. Given the apparent limited effectiveness of evacuation and indoor sheltering on internal contamination, the decision to implement such early responses to a radiation-release incident should be made by carefully balancing their potential benefits and health risks. © The Author 2015. Published by Oxford University Press. All rights reserved. For

  5. A parameter quantifying radiation damping of bay oscillations excited by incident tsunamis

    Science.gov (United States)

    Endoh, Takahiro; Inazu, Daisuke; Waseda, Takuji; Hibiya, Toshiyuki

    2018-04-01

    The transient response of a bay with a narrow mouth to incident tsunamis is interpreted as the convolution of the input signal with the impulse response obtained by an inverse Fourier transform of the response curve of the oscillatory system with one degree of freedom. The rate of radiation damping associated with energy escaping seaward through the bay mouth is expressed in terms of the quality factor Q, which determines the decaying envelope of the impulse response. The value of Q of the resonant peak is approximated by the ratio of the resonant frequency ω0 to the bandwidth between frequencies at which the power spectral density of sea level within the bay drops to half of the peak value. Since the shape of the frequency power spectrum during the tsunami event is almost similar to that in the normal state in the neighborhood of ω0, Q can be estimated from sea level datasets in the normal state. Although the amplitude and phase of the impulse response need to be adjusted using the first crest or trough of the observed leading wave, this approach proves to work well in examining the transient responses of Miyako Bay and Kushimoto Bay on the Japanese Pacific coast to incident tsunamis.

  6. Recovery from Iridium-192 flakes of a radioactive source for industrial use after a radiation incident

    International Nuclear Information System (INIS)

    Cruz, W.H.; Zapata, L.A.

    2013-01-01

    The Iridium-192 ( 192 Ir) is the most used and ideal for industrial radiography applications, especially in petrochemical plants and pipelines and provides better contrast sensitivity for thick (25.4 mm). This source has constructive sealed double encapsulation, the internal capsule containing stainless steel to radioactive material in the form of flakes and welded with TIG process. The radiological incident happened at a gas station fuel sales in circumstances in which there was a homogeneity test welds a tank, the flakes or Ir-192 fell off his ponytail and left scattered over an area of 2 m 2 , some fell flat areas and other land so collected in lead shielding and metal container and ground source. Full recovery of the leaflets was performed at the Division of radioactive waste management (GRRA) gaining a total of 22 flakes with no radiation risk to staff performance and installation and the conclusion was reached that the misapplicaion of TIG welding was the main cause the incident. (author)

  7. Incidence of Leukoencephalopathy After Whole-Brain Radiation Therapy for Brain Metastases

    International Nuclear Information System (INIS)

    Ebi, Junko; Sato, Hisashi; Nakajima, Masaru; Shishido, Fumio

    2013-01-01

    Purpose: To evaluate the incidence of leukoencephalopathy after whole-brain radiation therapy (WBRT) in patients with brain metastases. Methods and Materials: We retrospectively reviewed 111 patients who underwent WBRT for brain metastases from April 2001 through March 2008 and had evaluable computed tomography (CT) and/or magnetic resonance imaging (MRI) at least 1 month after completion of WBRT. We evaluated the leukoencephalopathy according to the Common Terminology Criteria for Adverse Events, version 3.0. The patients who had brain tumor recurrence after WBRT were censored at the last follow-up CT or MRI without recurrence. To evaluate the risk factors for leukoencephalopathy, bivariate analysis was performed using a logistic regression analysis adjusted for follow-up time. Factors included in the analysis were age, gender, dose fractionation, 5-fluorouracil, methotrexate, cisplatin, and other chemotherapeutic agents. Results: The median age of the 111 patients was 60.0 years (range, 23-89 years). The median follow-up was 3.8 months (range, 1.0-38.1 months). Leukoencephalopathy developed in 23 of the 111 patients. Grades 1, 2, and 3 were observed in 8, 7, and 8 patients, respectively. The incidence was 34.4% (11 of 32), 42.9% (6 of 14), 66.7% (2 of 3), and 100% (2 of 2) of the patients who were followed up for ≥6, ≥12, ≥24, and ≥36 months, respectively. In the bivariate analysis, older age (≥65 years) was significantly correlated with higher risk of leukoencephalopathy (odds ratio 3.31; 95% confidence interval 1.15-9.50; P=.03). Conclusions: The incidence of leukoencephalopathy after WBRT was 34.4% with ≥6 months follow-up, and increased with longer follow-up. Older age was a significant risk factor. The schedule of WBRT for patients with brain metastases should be carefully determined, especially for favorable patients

  8. Incidence of Leukoencephalopathy After Whole-Brain Radiation Therapy for Brain Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Ebi, Junko, E-mail: junkoe@fmu.ac.jp [Department of Radiology, Fukushima Medical University, Fukushima (Japan); Sato, Hisashi; Nakajima, Masaru; Shishido, Fumio [Department of Radiology, Fukushima Medical University, Fukushima (Japan)

    2013-04-01

    Purpose: To evaluate the incidence of leukoencephalopathy after whole-brain radiation therapy (WBRT) in patients with brain metastases. Methods and Materials: We retrospectively reviewed 111 patients who underwent WBRT for brain metastases from April 2001 through March 2008 and had evaluable computed tomography (CT) and/or magnetic resonance imaging (MRI) at least 1 month after completion of WBRT. We evaluated the leukoencephalopathy according to the Common Terminology Criteria for Adverse Events, version 3.0. The patients who had brain tumor recurrence after WBRT were censored at the last follow-up CT or MRI without recurrence. To evaluate the risk factors for leukoencephalopathy, bivariate analysis was performed using a logistic regression analysis adjusted for follow-up time. Factors included in the analysis were age, gender, dose fractionation, 5-fluorouracil, methotrexate, cisplatin, and other chemotherapeutic agents. Results: The median age of the 111 patients was 60.0 years (range, 23-89 years). The median follow-up was 3.8 months (range, 1.0-38.1 months). Leukoencephalopathy developed in 23 of the 111 patients. Grades 1, 2, and 3 were observed in 8, 7, and 8 patients, respectively. The incidence was 34.4% (11 of 32), 42.9% (6 of 14), 66.7% (2 of 3), and 100% (2 of 2) of the patients who were followed up for ≥6, ≥12, ≥24, and ≥36 months, respectively. In the bivariate analysis, older age (≥65 years) was significantly correlated with higher risk of leukoencephalopathy (odds ratio 3.31; 95% confidence interval 1.15-9.50; P=.03). Conclusions: The incidence of leukoencephalopathy after WBRT was 34.4% with ≥6 months follow-up, and increased with longer follow-up. Older age was a significant risk factor. The schedule of WBRT for patients with brain metastases should be carefully determined, especially for favorable patients.

  9. Effects of radiation on the incidence of prostate cancer among Nagasaki atomic bomb survivors.

    Science.gov (United States)

    Kondo, Hisayoshi; Soda, Midori; Mine, Mariko; Yokota, Kenichi

    2013-10-01

    Atomic bomb survivors have been reported to have an increased risk of some cancers, especially leukemia. However, the risk of prostate cancer in atomic bomb survivors is not known to have been examined previously. This study examined the association between atomic bomb radiation and the incidence of prostate cancer among male Nagasaki atomic bomb survivors. The subjects were classified by distance from the hypocenter into a proximal group (<2 km), a distal group (≥2 km), and an early entrance group (those who entered the region <2 km from the hypocenter within 2 weeks after the explosion). Between 1996 and 2009, 631 new cases of prostate cancer were identified among approximately 18 400 male Nagasaki atomic bomb survivors who were alive in 1996. The Cox proportional hazard model was used to estimate the risk of prostate cancer development, with adjustment for age at atomic bomb explosion, attained age, smoking status, and alcohol consumption. Compared with the distal group, the proximal group had significant increased risks of total, localized, and high-grade prostate cancer (relative risk and 95% confidence interval: 1.51 [1.21-1.89]; 1.80 [1.26-2.57]; and 1.88 [1.20-2.94], respectively). This report is the first known to reveal a significant relationship between atomic bomb radiation and prostate cancer. © 2013 Japanese Cancer Association.

  10. TU-D-201-04: Veracity of Data Elements in Radiation Oncology Incident Learning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Kapur, A [Northwell Health System, New Hyde Park, NY (United States); Evans, S [Yale University New Haven, CT (United States); Brown, D [University of California, San Diego, La Jolla, CA (United States); Ezzell, G [Mayo Clinic Arizona, Phoenix, AZ (United States); Hoopes, D [The University of California San Diego, San Diego, CA (United States); Dieterich, S [UC Davis Medical Center, Sacramento, CA (United States); Kapetanovic, K; Tomlinson, C [American Society for Radiation Oncology, Fairfax, VA (United States)

    2016-06-15

    Purpose: Incident learning systems encompass volumes, varieties, values, and velocities of underlying data elements consistent with the V’s of big data. Veracity, the 5th V however exists only if there is high inter-rater reliability (IRR) within the data elements. The purpose of this work was to assess IRR in the nationally deployed RO-ILS: Radiation Oncology-Incident Learning System (R) sponsored by the American Society for Radiation Oncology (ASTRO) and the American Association of Physicists in Medicine (AAPM). Methods: Ten incident reports covering a wide range of scenarios were created in standardized narrative and video formats and disseminated to 67 volunteers of multiple disciplines from 26 institutions along with two published narratives from the International Commission of Radiological Protection to assess IRR on a nationally representative level. The volunteers were instructed to independently enter the associated data elements in a test version of RO-ILS over a 3-week period. All responses were aggregated into a spreadsheet to assess IRR using free-marginal kappa metrics. Results: 48 volunteers from 21 institutions completed all reports in the study period. The average kappa score for all raters across all critical data elements was 0.659 [range 0.326–1.000]. Statistically significant differences (p <0.05) were noted between reporters of different disciplines and raters with varying levels of experience. Kappa scores were high for event classification (0.781) and contributory factors (0.777) and low for likelihood-of-harm (0.326). IRR was highest among AAPM-ASTRO members (0.672) and lowest among trainees (0.463). Conclusion: A moderate-to-substantial level of IRR in RO-ILS was noted in this study. Although the number of events reviewed in this study was small, opportunities for improving the taxonomy for the lower scoring data elements as well as specific educational targets for training were identified by assessing data veracity quantitatively

  11. TU-D-201-04: Veracity of Data Elements in Radiation Oncology Incident Learning Systems

    International Nuclear Information System (INIS)

    Kapur, A; Evans, S; Brown, D; Ezzell, G; Hoopes, D; Dieterich, S; Kapetanovic, K; Tomlinson, C

    2016-01-01

    Purpose: Incident learning systems encompass volumes, varieties, values, and velocities of underlying data elements consistent with the V’s of big data. Veracity, the 5th V however exists only if there is high inter-rater reliability (IRR) within the data elements. The purpose of this work was to assess IRR in the nationally deployed RO-ILS: Radiation Oncology-Incident Learning System (R) sponsored by the American Society for Radiation Oncology (ASTRO) and the American Association of Physicists in Medicine (AAPM). Methods: Ten incident reports covering a wide range of scenarios were created in standardized narrative and video formats and disseminated to 67 volunteers of multiple disciplines from 26 institutions along with two published narratives from the International Commission of Radiological Protection to assess IRR on a nationally representative level. The volunteers were instructed to independently enter the associated data elements in a test version of RO-ILS over a 3-week period. All responses were aggregated into a spreadsheet to assess IRR using free-marginal kappa metrics. Results: 48 volunteers from 21 institutions completed all reports in the study period. The average kappa score for all raters across all critical data elements was 0.659 [range 0.326–1.000]. Statistically significant differences (p <0.05) were noted between reporters of different disciplines and raters with varying levels of experience. Kappa scores were high for event classification (0.781) and contributory factors (0.777) and low for likelihood-of-harm (0.326). IRR was highest among AAPM-ASTRO members (0.672) and lowest among trainees (0.463). Conclusion: A moderate-to-substantial level of IRR in RO-ILS was noted in this study. Although the number of events reviewed in this study was small, opportunities for improving the taxonomy for the lower scoring data elements as well as specific educational targets for training were identified by assessing data veracity quantitatively

  12. Selective surface functionalization of poly(butadiene) using inner-shell monochromatic excitation and exposition to a reactive gaseous atmosphere

    International Nuclear Information System (INIS)

    Kessler, Felipe; Ramanathan, Rajajeyaganthan; Weibel, Daniel E.

    2011-01-01

    Recent studies showed that in low power plasma treatments the surface radical species are mainly generated by VUV-UV radiation and not by ions. Synchrotron radiation offers the potential to excite inner-shell electrons in the required power range (1-4 nm), besides the possibility of its extreme monochromaticity. Thin films (∼ 200 nm) of poly(butadiene) (PBU) have been selectively functionalized with the combination of monochromatic synchrotron radiation and exposure to oxygen atmosphere. The experiments were conducted in the SGM line, LNLS (C 1s edge). NEXAFS spectra were obtained before and after irradiation at different times and energies. High and efficient surface functionalization of PBU films by the introduction of oxygenated groups were observed when specific excitation energies of K-shell were selected. Similar results were previously reported for polystyrene showing that the Auger stimulated desorption mechanisms are involved in the process. (author)

  13. Enhancing monochromatic multipole emission by a subwavelength enclosure of degenerate Mie resonances

    KAUST Repository

    Zhao, Jiajun

    2017-07-06

    Sound emission is inefficient at low frequencies as limited by source size. This letter presents enhancing emission of monochromatic monopole and multipole sources by enclosing the source with a subwavelength circular enclosure filled of an anisotropic material of a low radial sound speed. The anisotropy is associated with an infinite tangential density along the azimuth. Numerical simulations show that emission gain is produced at frequencies surrounding degenerate Mie resonant frequencies of the enclosure, and meanwhile the radiation directivity pattern is well preserved. The degeneracy is theoretically analyzed. A realization of the material is suggested by using a space-coiling structure.

  14. Development of highly polished, grazing incidence mirrors for synchrotron radiation beam lines at SSRL

    International Nuclear Information System (INIS)

    Tirsell, K.G.; Berglin, E.J.; Fuchs, B.A.; Holdener, F.R.; Humpal, H.H.; Karpenko, V.P.; Kulkarni, S.; Fantone, S.D.

    1987-08-01

    New platinum-coated grazing incidence mirrors with low surface roughnesses have been developed to focus bending magnet radiation from the SSRL/SLAC SPEAR storage ring on the entrance slits of two Beam Line VIII grating monochromators. The first mirror in the toroidal grating monochromator (TGM) branch is a cooled SiC cylinder capable of absorbing synchrotron radiation power levels of up to 260 watts without excessive distortion. This mirror deflects the beam vertically through a 12/degree/ angle and focuses it sagitally on the TGM entrance slit plane. The second TGM optical element is a fused-silica spherical mirror with a large radius of curvature that deflects the beam vertically through an additional 12/degree/ and focuses it tangentially with 3/1 demagnification. The first mirror in our spherical grating branch is a 5/degree/-vertically deflecting, cooled SiC toroid designed to focus tangentially on the monochromator entrance slits and sagitally in the exit slits. A 4/degree/-deflecting fused silica mirror is used after the exit sites in each beam line to refocus on to the sample. For this application a thin cylinder is bent to approximate an ellipsoid. The mirrors are now installed at SSRL and performance measurements are planned. Qualitatively the focus of the TGM optics at the entrance slit plane appears very good. In this paper we discuss considerations leading to the choice of SiC for each of the two first mirrors. We present highlights of the development of these mirrors with some emphasis on SiC polishing techniques. In addition, the specialized metrology developed to produce the more difficult figure of the toroid will be described. Measured surface roughness and figure results will be presented. 19 refs., 11 figs

  15. Development of highly polished, grazing incidence mirrors for synchrotron radiation beam lines at SSRL

    Energy Technology Data Exchange (ETDEWEB)

    Tirsell, K.G.; Berglin, E.J.; Fuchs, B.A.; Holdener, F.R.; Humpal, H.H.; Karpenko, V.P.; Kulkarni, S.; Fantone, S.D.

    1987-08-01

    New platinum-coated grazing incidence mirrors with low surface roughnesses have been developed to focus bending magnet radiation from the SSRL/SLAC SPEAR storage ring on the entrance slits of two Beam Line VIII grating monochromators. The first mirror in the toroidal grating monochromator (TGM) branch is a cooled SiC cylinder capable of absorbing synchrotron radiation power levels of up to 260 watts without excessive distortion. This mirror deflects the beam vertically through a 12/degree/ angle and focuses it sagitally on the TGM entrance slit plane. The second TGM optical element is a fused-silica spherical mirror with a large radius of curvature that deflects the beam vertically through an additional 12/degree/ and focuses it tangentially with 3/1 demagnification. The first mirror in our spherical grating branch is a 5/degree/-vertically deflecting, cooled SiC toroid designed to focus tangentially on the monochromator entrance slits and sagitally in the exit slits. A 4/degree/-deflecting fused silica mirror is used after the exit sites in each beam line to refocus on to the sample. For this application a thin cylinder is bent to approximate an ellipsoid. The mirrors are now installed at SSRL and performance measurements are planned. Qualitatively the focus of the TGM optics at the entrance slit plane appears very good. In this paper we discuss considerations leading to the choice of SiC for each of the two first mirrors. We present highlights of the development of these mirrors with some emphasis on SiC polishing techniques. In addition, the specialized metrology developed to produce the more difficult figure of the toroid will be described. Measured surface roughness and figure results will be presented. 19 refs., 11 figs.

  16. Imaging-therapy computed tomography with quasi-monochromatic X-rays.

    Science.gov (United States)

    Jost, Gregor; Golfier, Sven; Lawaczeck, Ruediger; Weinmann, Hanns-Joachim; Gerlach, Martin; Cibik, Levent; Krumrey, Michael; Fratzscher, Daniel; Rabe, Johannis; Arkadiev, Vladimir; Haschke, Michael; Langhoff, Norbert; Wedell, Reiner; Luedemann, Lutz; Wust, Peter; Pietsch, Hubertus

    2008-12-01

    Computed tomography (CT) is a widespread and highly precise technique working in the energy range around 50-100 keV. For radiotherapy, however, the MeV energy range enables a better dose distribution. This gap between diagnosis and therapy can be overcome by the use of a modified CT machine in combination with heavy elements targeted to the tumour and used as photoelectric radiation enhancer. The experimental setup consists of an X-ray optical module mounted at the exit of the X-ray tube of a clinical CT. The module converts the standard fan-shaped beam into a high intensity, monochromatized and focused beam. The radiation was characterized using an energy-dispersive detection system calibrated by synchrotron radiation and gel dosimetry. The photoelectric radiation enhancement for different elements was calculated and experimentally verified. The X-ray optical module filters selectively the energy of the tungsten K alpha-emission line (59.3 keV) with a full width at half maximum (FWHM) of 5 keV and focused the radiation onto a focal spot which coincides with the isocentre of the gantry. This results in a steep dose gradient at the centre of rotation qualified for locoregional radiation therapy. The photon energy of the quasi-monochromatic radiation agrees with the energy range of maximal photoelectric dose enhancement for gadolinium and iodine. An additional X-ray optical module optimized for targeted therapy and photoelectric dose enhancement allows the combination of diagnosis and radiotherapy on a clinical CT.

  17. Imaging-therapy computed tomography with quasi-monochromatic X-rays

    International Nuclear Information System (INIS)

    Jost, Gregor; Golfier, Sven; Lawaczeck, Ruediger; Weinmann, Hanns-Joachim; Gerlach, Martin; Cibik, Levent; Krumrey, Michael; Fratzscher, Daniel; Rabe, Johannis; Arkadiev, Vladimir; Haschke, Michael; Langhoff, Norbert; Wedell, Reiner

    2008-01-01

    Introduction: Computed tomography (CT) is a widespread and highly precise technique working in the energy range around 50-100 keV. For radiotherapy, however, the MeV energy range enables a better dose distribution. This gap between diagnosis and therapy can be overcome by the use of a modified CT machine in combination with heavy elements targeted to the tumour and used as photoelectric radiation enhancer. Materials and methods: The experimental setup consists of an X-ray optical module mounted at the exit of the X-ray tube of a clinical CT. The module converts the standard fan-shaped beam into a high intensity, monochromatized and focused beam. The radiation was characterized using an energy-dispersive detection system calibrated by synchrotron radiation and gel dosimetry. The photoelectric radiation enhancement for different elements was calculated and experimentally verified. Results: The X-ray optical module filters selectively the energy of the tungsten Kα-emission line (59.3 keV) with a full width at half maximum (FWHM) of 5 keV and focused the radiation onto a focal spot which coincides with the isocentre of the gantry. This results in a steep dose gradient at the centre of rotation qualified for locoregional radiation therapy. The photon energy of the quasi-monochromatic radiation agrees with the energy range of maximal photoelectric dose enhancement for gadolinium and iodine. Conclusion: An additional X-ray optical module optimized for targeted therapy and photoelectric dose enhancement allows the combination of diagnosis and radiotherapy on a clinical CT

  18. Imaging-therapy computed tomography with quasi-monochromatic X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Jost, Gregor [Bayer Schering Pharma AG, Contrast Media Research, Muellerstrasse 178, 13353 Berlin (Germany)], E-mail: gregor.jost@bayerhealthcare.com; Golfier, Sven [Bayer Schering Pharma AG, Contrast Media Research, Muellerstrasse 178, 13353 Berlin (Germany)], E-mail: sven.golfier@bayerhealthcare.com; Lawaczeck, Ruediger [Bayer Schering Pharma AG, Contrast Media Research, Muellerstrasse 178, 13353 Berlin (Germany)], E-mail: ruediger.lawaczeck@bayerhealthcare.com; Weinmann, Hanns-Joachim [Bayer Schering Pharma AG, Contrast Media Research, Muellerstrasse 178, 13353 Berlin (Germany)], E-mail: hanns-joachim.weinmann@bayerhealthcare.com; Gerlach, Martin [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany)], E-mail: martin.gerlach@ptb.de; Cibik, Levent [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany)], E-mail: levent.cibik@ptb.de; Krumrey, Michael [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany)], E-mail: michael.krumrey@ptb.de; Fratzscher, Daniel [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Fratzscher@ifg-adlershof.de; Rabe, Johannis [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Rabe@ifg-adlershof.de; Arkadiev, Vladimir [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Arkadiev@ifg-adlershof.de; Haschke, Michael [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Haschke@ifg-adlershof.de; Langhoff, Norbert [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Langhoff@ifg-adlershof.de; Wedell, Reiner [Institut fuer angewandte Photonik e.V., Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: wedell-iap@ifg-adlershof.de (and others)

    2008-12-15

    Introduction: Computed tomography (CT) is a widespread and highly precise technique working in the energy range around 50-100 keV. For radiotherapy, however, the MeV energy range enables a better dose distribution. This gap between diagnosis and therapy can be overcome by the use of a modified CT machine in combination with heavy elements targeted to the tumour and used as photoelectric radiation enhancer. Materials and methods: The experimental setup consists of an X-ray optical module mounted at the exit of the X-ray tube of a clinical CT. The module converts the standard fan-shaped beam into a high intensity, monochromatized and focused beam. The radiation was characterized using an energy-dispersive detection system calibrated by synchrotron radiation and gel dosimetry. The photoelectric radiation enhancement for different elements was calculated and experimentally verified. Results: The X-ray optical module filters selectively the energy of the tungsten K{alpha}-emission line (59.3 keV) with a full width at half maximum (FWHM) of 5 keV and focused the radiation onto a focal spot which coincides with the isocentre of the gantry. This results in a steep dose gradient at the centre of rotation qualified for locoregional radiation therapy. The photon energy of the quasi-monochromatic radiation agrees with the energy range of maximal photoelectric dose enhancement for gadolinium and iodine. Conclusion: An additional X-ray optical module optimized for targeted therapy and photoelectric dose enhancement allows the combination of diagnosis and radiotherapy on a clinical CT.

  19. Incidence, Causative Mechanisms, and Anatomic Localization of Stroke in Pituitary Adenoma Patients Treated With Postoperative Radiation Therapy Versus Surgery Alone

    Energy Technology Data Exchange (ETDEWEB)

    Sattler, Margriet G.A., E-mail: g.a.sattler@umcg.nl [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON (Canada); Vroomen, Patrick C. [Department of Neurology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Sluiter, Wim J. [Department of Endocrinology and Metabolic Diseases, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Schers, Henk J. [Department of Primary and Community Care, Radboud University Nijmegen Medical Centre (Netherlands); Berg, Gerrit van den [Department of Endocrinology and Metabolic Diseases, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Langendijk, Johannes A. [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Wolffenbuttel, Bruce H.R. [Department of Endocrinology and Metabolic Diseases, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Bergh, Alphons C.M. van den [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Beek, André P. van [Department of Endocrinology and Metabolic Diseases, University of Groningen, University Medical Center Groningen, Groningen (Netherlands)

    2013-09-01

    Purpose: To assess and compare the incidence of stroke and stroke subtype in pituitary adenoma patients treated with postoperative radiation therapy (RT) and surgery alone. Methods and Materials: A cohort of 462 pituitary adenoma patients treated between 1959 and 2008 at the University Medical Center Groningen in The Netherlands was studied. Radiation therapy was administered in 236 patients. The TOAST (Trial of ORG 10172 in Acute Stroke Treatment) and the Oxfordshire Community Stroke Project classification methods were used to determine causative mechanism and anatomic localization of stroke. Stroke incidences in patients treated with RT were compared with that observed after surgery alone. Risk factors for stroke incidence were studied by log–rank test, without and with stratification for other significant risk factors. In addition, the stroke incidence was compared with the incidence rate in the general Dutch population. Results: Thirteen RT patients were diagnosed with stroke, compared with 12 surgery-alone patients. The relative risk (RR) for stroke in patients treated with postoperative RT was not significantly different compared with surgery-alone patients (univariate RR 0.62, 95% confidence interval [CI] 0.28-1.35, P=.23). Stroke risk factors were coronary or peripheral artery disease (univariate and multivariate RR 10.4, 95% CI 4.7-22.8, P<.001) and hypertension (univariate RR 3.9, 95% CI 1.6-9.8, P=.002). There was no difference in TOAST and Oxfordshire classification of stroke. In this pituitary adenoma cohort 25 strokes were observed, compared with 16.91 expected (standard incidence ratio 1.48, 95% CI 1.00-1.96, P=.049). Conclusions: In pituitary adenoma patients, an increased incidence of stroke was observed compared with the general population. However, postoperative RT was not associated with an increased incidence of stroke or differences in causative mechanism or anatomic localization of stroke compared with surgery alone. The primary stroke risk

  20. Comment on "Collision monochromatization in e+e- colliders"

    Science.gov (United States)

    Shatilov, D.

    2018-02-01

    Bogomyagkov and Levichev [Phys. Rev. Accel. Beams 20, 051001 (2017), 10.1103/PhysRevAccelBeams.20.051001] have recently reported on monochromatization in collision schemes with crossing angle. From their results, in particular, it may seem that: (1) horizontal dispersion at the IP can provide monochromatization factor Λ ≫1 while retaining Piwinski angle ϕ >1 , (2) production rate in such a scheme for FCC-ee at 62.5 GeV can be larger than that in the nominal crab waist collision, and (3) strong rf focusing can be used for monochromatization purposes. We demonstrate here that the first two statements are not correct, and the last one is very doubtful.

  1. A correlation model to compute the incidence angle modifier and to estimate its effect on collectible solar radiation

    Energy Technology Data Exchange (ETDEWEB)

    Armenta-Deu, C. (Universidad Complutense de Madrid (ES). Facultad Fisicas); Lukac, B. (University of T. and C. Zilina (CS))

    1991-01-01

    The radiation transmittance and absorptance of materials vary according to the angle of incidence of the incoming solar radiation. Therefore, the efficiency of most solar converters (thermal or photovoltaic) is a function of the sun's position through the angle of incidence. This problem may be taken account of by the Incidence Angle Modifier, which is considered in this paper. An analytic expression for the incidence angle modifier, based on meteorological data or on geographic and geometric parameters, has been developed; this expression includes the effect of beam and diffuse radiation as well as the global influence. A comparison between measured data and these computed from our model has given a very good correlation, the results being within {+-}3% for horizontal and titled planes, and within {+-}7% for vertical surfaces, on average. The method also computes the collectible solar energy within a 5% error for thresholds up to 300Wm{sup -2}. The method has been validated for more than 30 locations in south and west Europe. (author).

  2. MO-G-BRE-09: Validating FMEA Against Incident Learning Data: A Study in Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Yang, F; Cao, N; Young, L; Howard, J; Sponseller, P; Logan, W; Arbuckle, T; Korssjoen, T; Meyer, J; Ford, E

    2014-01-01

    Purpose: Though FMEA (Failure Mode and Effects Analysis) is becoming more widely adopted for risk assessment in radiation therapy, to our knowledge it has never been validated against actual incident learning data. The objective of this study was to perform an FMEA analysis of an SBRT (Stereotactic Body Radiation Therapy) treatment planning process and validate this against data recorded within an incident learning system. Methods: FMEA on the SBRT treatment planning process was carried out by a multidisciplinary group including radiation oncologists, medical physicists, and dosimetrists. Potential failure modes were identified through a systematic review of the workflow process. Failure modes were rated for severity, occurrence, and detectability on a scale of 1 to 10 and RPN (Risk Priority Number) was computed. Failure modes were then compared with historical reports identified as relevant to SBRT planning within a departmental incident learning system that had been active for two years. Differences were identified. Results: FMEA identified 63 failure modes. RPN values for the top 25% of failure modes ranged from 60 to 336. Analysis of the incident learning database identified 33 reported near-miss events related to SBRT planning. FMEA failed to anticipate 13 of these events, among which 3 were registered with severity ratings of severe or critical in the incident learning system. Combining both methods yielded a total of 76 failure modes, and when scored for RPN the 13 events missed by FMEA ranked within the middle half of all failure modes. Conclusion: FMEA, though valuable, is subject to certain limitations, among them the limited ability to anticipate all potential errors for a given process. This FMEA exercise failed to identify a significant number of possible errors (17%). Integration of FMEA with retrospective incident data may be able to render an improved overview of risks within a process

  3. Stress measurements by multi-reflection grazing-incidence X-ray diffraction method (MGIXD) using different radiation wavelengths and different incident angles

    International Nuclear Information System (INIS)

    Marciszko, Marianna; Baczmański, Andrzej; Braham, Chedly; Wróbel, Mirosław; Wroński, Sebastian; Cios, Grzegorz

    2017-01-01

    The presented study introduces the development of the multi-reflection grazing-incidence X-ray diffraction method (MGIXD) for residual stress determination. The proposed new methodology is aimed at obtaining more reliable experimental data and increasing the depth of non-destructive stress determination below the sample surface. To verify proposed method measurements were performed on a classical X-ray diffractometer (Cu Kα radiation) and using synchrotron radiation (three different wavelengths: λ = 1.2527 Å, λ = 1.5419 Å and λ = 1.7512 Å). The Al2017 alloy subjected to three different surface treatments was investigated in this study. The obtained results showed that the proposed development of MGIXD method, in which not only different incident angles but also different wavelengths of X-ray are used, can be successfully applied for residual stress determination, especially when stress gradients are present in the sample.

  4. Incidence of primary hypothyroidism in patients exposed to therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland

    Directory of Open Access Journals (Sweden)

    B A Laway

    2012-01-01

    Full Text Available Introduction: Hypothyroidism is a known consequence of external-beam radiotherapy to the neck encompassing a part or whole of the thyroid gland. In this non-randomized prospective study, we have tried to evaluate the response of the thyroid gland to radiation by assessing thyroid function before irradiation and at regular intervals after irradiation. Aims and Objectives: The aim of this study were to assess in the cancer patients, who were exposed to the therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland: the incidence of primary hypothyroidism, the time required to become hypothyroid, any relation between the total dose for the development of hypothyroidism, and whether there are any patient or treatment-related factors that are predictive for the development of hypothyroidism, including the use of concurrent chemotherapy. Materials and Methods: This non-randomized, prospective study was conducted for a period of 2 years in which thyroid function was assessed in 59 patients (cases of head and neck cancer, breast cancer, lymphoma patients and other malignancies, who had received radiotherapy to the neck region. 59 euthyroid healthy patients (controls were also taken, who had not received the neck irradiation. These patients/controls were assessed periodically for 2 years. Results: The incidence of hypothyroidism after external beam radiation therapy (EBRT to neck where radiation portals include part or whole of the thyroid gland was 16.94%, seven cases had subclinical hypothyroidism (11.86% and three cases had clinical hypothyroidism (5.08%. Mean time for development of hypothyroidism was 4.5 months. There was no effect of age, gender, primary tumor site, radiation dose and chemotherapy, whether neoadjuvant or concurrent with the development of hypothyroidism. Conclusion: In summary, we found that thyroid dysfunction is a prevalent, yet easily treatable source of morbidity in patients

  5. Pilot Study for the Creation of a European Union Radiation Accident and Incident Data Exchange System (EURAIDE)

    International Nuclear Information System (INIS)

    Stewart, J.E.; Lefaure, C; Czarwinski, R.

    2004-01-01

    This study has had the objective of evaluating the feasibility of: (i) facilitating the establishment of national radiation accident and incident databases where there are none and to encourage the compatibility of such databases, (ii) establishing a European network to exchange radiological protection feedback from accidents and incidents, (iii) establishing summary reports of relevant accidents and incidents with the aim of identifying lessons to be learned, so that they can be used in radiation protection training programs, and (iv) upgrading the radiological safety in the countries applying to join the EU, by integrating them into the above efficient feedback exchange system. This report details the first stage of the project, which was to review the status of existing (or proposed) national mechanisms for collating data on radiation incidents. The objectives of this initial review were to: i) obtain detailed information regarding the means of capturing and collating data, the format of established or proposed data systems and accessibility of the final data, ii) to use this information to consider how a European platform to gather relevant data/accident reports might be established., and iii) to consider how the various elements of national data systems might be harmonised in order to facilitate the presentation and distribution of lessons learned. It was considered that the key aspects that would need to be addressed in order to determine the feasibility of a European wide data exchange mechanism were: - the criteria used for the classification and categorisation of incidents, - criteria for the selection of incidents from national data systems for inclusion in a European-wide system, - the implication of possible language problems. In order to illicit the required information a detailed questionnaire was sent to a total of 31 countries, being existing European Member States, applicant or associated countries. A full list of the countries and institutions

  6. Ultraviolet Radiation and Kaposi Sarcoma Incidence in a Nationwide US Cohort of HIV-Infected Men.

    Science.gov (United States)

    Cahoon, Elizabeth K; Engels, Eric A; Freedman, D Michal; Norval, Mary; Pfeiffer, Ruth M

    2017-05-01

    Although ultraviolet radiation (UVR) is established as both an inducer of herpes simplex virus reactivation and as the primary risk factor for many common skin cancers, its relationship with human herpes virus 8 (HHV8) infection or risk of Kaposi sarcoma (KS) is unknown. Hazard ratios (HRs) and 95% confidence intervals (CIs) were estimated for the association between ambient UVR, history of nonmelanoma skin cancer (NMSC; as a biomarker of personal cumulative UVR dose), and incidence of first primary KS in a nationwide US cohort of white and African American male veterans infected with HIV between 1986 and 1996 (prior to the widespread availability of treatment) using Cox regression. All statistical tests were two-sided. Based on discharge records, there were 422 newly diagnosed KS cases among 17 597 HIV-infected veterans. Cohort members with prior NMSC had a statistically significantly increased risk of KS (HR = 8.64, 95% CI = 6.23 to 11.96) in the total population. Risk of KS was higher for quartile 4 vs 1 among the total population (HR = 1.49, 95% CI = 1.02 to 2.16, P trend UVR quartile [coded 1 to 4] = .02) and among whites (HR = 1.75, 95% CI = 1.11 to 2.78, P trend = .009), but not among African Americans (HR = 1.23, 95% CI = 0.71 to 2.15, P trend = .23). KS risk was elevated among HIV-infected men with NMSC diagnosis and in those living in locations with high ambient UVR at time of HIV diagnosis. Our novel findings suggesting that UVR exposure may increase KS risk warrant further investigation. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  7. Vegetative and reproductive plasticity of broccoli at three levels of incident photosynthetically active radiation

    International Nuclear Information System (INIS)

    Francescangeli, N.; Martí, H.R.; Sangiacomo, M.A.

    2007-01-01

    To study the effects of shading on the growth, development, dry matter partitioning, and plant architecture of broccoli, ‘Legacy’ hybrid plants were grown in pots in a greenhouse under black shading meshes to generate different levels of photosynthetically active radiation (PAR). The average incident PAR was 23 mol PPF m –2 d –1 under control conditions, 15.2 under a 35% mesh, and 6.7 under a 70% mesh. The air temperature was within the range 15-22°C. As shading increased so did the duration of the growth cycle and the leaf area (LA). Shading did not affect the number of leaves, although the upper ones were more erect. The stem length and the accumulated intercepted PAR (IPAR) were negatively related. Inflorescence diameter and commercial fresh weight decreased only with the 70% mesh. Shading did not affect stem dry weight (DW) but altered dry matter allocation in the root and spear. The DW of the leaves maintained an average 45.7% of the total DW despite the greater LA developed under shade. The net assimilation rate diminished with the reduction of IPAR, and the LA increased; the plant relative growth rate was therefore practically constant. With increased shading, the leaves and the stem became the dominant photosynthate sinks. The commercial fresh weight achieved with 15.2 mol photosynthetic photon flux (PPF) m –2 d –1 was equivalent to that obtained with 23 mol PPF m –2 d –1 , but the cycle was extended for 4.5 days. With 6.7 mol PPF m –2 d –1 , yield diminished because of the lower DW produced in a cycle extended by 15 days, and because more dry matter was allocated to the stem than to the spear. Based on these results, broccoli could be considered a shade-tolerant plant. (author) [es

  8. Developing Multivariable Normal Tissue Complication Probability Model to Predict the Incidence of Symptomatic Radiation Pneumonitis among Breast Cancer Patients.

    Science.gov (United States)

    Lee, Tsair-Fwu; Chao, Pei-Ju; Chang, Liyun; Ting, Hui-Min; Huang, Yu-Jie

    2015-01-01

    Symptomatic radiation pneumonitis (SRP), which decreases quality of life (QoL), is the most common pulmonary complication in patients receiving breast irradiation. If it occurs, acute SRP usually develops 4-12 weeks after completion of radiotherapy and presents as a dry cough, dyspnea and low-grade fever. If the incidence of SRP is reduced, not only the QoL but also the compliance of breast cancer patients may be improved. Therefore, we investigated the incidence SRP in breast cancer patients after hybrid intensity modulated radiotherapy (IMRT) to find the risk factors, which may have important effects on the risk of radiation-induced complications. In total, 93 patients with breast cancer were evaluated. The final endpoint for acute SRP was defined as those who had density changes together with symptoms, as measured using computed tomography. The risk factors for a multivariate normal tissue complication probability model of SRP were determined using the least absolute shrinkage and selection operator (LASSO) technique. Five risk factors were selected using LASSO: the percentage of the ipsilateral lung volume that received more than 20-Gy (IV20), energy, age, body mass index (BMI) and T stage. Positive associations were demonstrated among the incidence of SRP, IV20, and patient age. Energy, BMI and T stage showed a negative association with the incidence of SRP. Our analyses indicate that the risk of SPR following hybrid IMRT in elderly or low-BMI breast cancer patients is increased once the percentage of the ipsilateral lung volume receiving more than 20-Gy is controlled below a limitation. We suggest to define a dose-volume percentage constraint of IV20radiation therapy treatment planning to maintain the incidence of SPR below 20%, and pay attention to the sequelae especially in elderly or low-BMI breast cancer patients. (AIV20: the absolute ipsilateral lung volume that received more than 20 Gy (cc).

  9. Monochromatic Mammographic Imaging Using X-Ray Polycapillary Optics

    National Research Council Canada - National Science Library

    Surgiro, Frannieoa

    2001-01-01

    .... The transmission is about 39% at 17.5 keV. The measurements agree quite well with simulations. Monochromatic imaging was performed using this optic with two different sources, a rotating anode copper source and a low power molybdenum source...

  10. Neutron diffraction on a grating with monochromatic and polychromatic neutrons

    International Nuclear Information System (INIS)

    Baumann, J.; Kalus, J.

    1989-01-01

    Neutron diffraction experiments on a grating using monochromatic and polychromatic neutrons are described. The grating constant G was 60 μm. By the use of an achromatic system we were able to observe higher order diffraction maxima even with a wavelength spread of Δλ/λ=0.5. (orig.)

  11. High efficiency quasi-monochromatic infrared emitter

    Energy Technology Data Exchange (ETDEWEB)

    Brucoli, Giovanni; Besbes, Mondher; Benisty, Henri, E-mail: henri.benisty@institutoptique.fr; Greffet, Jean-Jacques [Laboratoire Charles Fabry, UMR 8501, Institut d’Optique, CNRS, Université Paris-Sud 11, 2, Avenue Augustin Fresnel, 91127 Palaiseau Cedex (France); Bouchon, Patrick; Haïdar, Riad [Office National d’Études et de Recherches Aérospatiales, Chemin de la Hunière, 91761 Palaiseau (France)

    2014-02-24

    Incandescent radiation sources are widely used as mid-infrared emitters owing to the lack of alternative for compact and low cost sources. A drawback of miniature hot systems such as membranes is their low efficiency, e.g., for battery powered systems. For targeted narrow-band applications such as gas spectroscopy, the efficiency is even lower. In this paper, we introduce design rules valid for very generic membranes demonstrating that their energy efficiency for use as incandescent infrared sources can be increased by two orders of magnitude.

  12. The incidence of breast cancer following mantle field radiation therapy as a function of dose and technique

    International Nuclear Information System (INIS)

    Tinger, Alfred; Wasserman, Todd H.; Klein, Eric E.; Miller, Elizabeth A.; Roberts, Tracy; Piephoff, James V.; Kucik, Nancy A.

    1997-01-01

    Purpose: There is an increased incidence of breast cancer following mantle field radiation therapy for Hodgkin's disease (HD). We reviewed the experience at the Mallinckrodt Institute of Radiology (MIR) for radiation factors related to the development of breast cancer after mantle field radiation therapy for HD. Methods: The radiation therapy records of 152 women treated with mantle field irradiation for HD at MIR between 1966-1985 were reviewed for the development of breast cancer and treatment-related factors. All patients had a minimum of 5 years of follow-up. The treatment era (1966-1974 vs. 1975-1985), stage of HD, mediastinal dose, axillary dose, maximum dose from the anterior field (anterior d max dose), the anterior-posterior:posterior-anterior (AP:PA) ratio, age at the time of treatment, length of follow-up, and history of splenectomy were analyzed as possible contributing factors for the development of breast cancer. The observed number of breast cancers was compared to the expected number based on age-adjusted incidences from the Connecticut Tumor Registry. Results: Ten breast cancers occurred in the population. Eight involved an upper outer quadrant. In a multivariate analysis, the development of breast cancer was significantly associated with axillary dose. Patients in the early treatment era were at an increased risk for the development of breast cancer due to high anterior d max and breast doses from weighting the fields anteriorly on a low energy linear accelerator. The use of current radiation therapy techniques was not related to an increased risk of breast cancer with a median follow-up of 13 years. Conclusions: A high dose to the axilla and the anterior d max point is significantly associated with the development of breast cancer after mantle field irradiation for HD. Efforts to protect the breast from high doses will likely lessen the increased risk of breast cancer in women treated with radiation therapy for HD

  13. Pathophysiological effects of radiation on atherosclerosis development and progression, and the incidence of cardiovascular complications

    International Nuclear Information System (INIS)

    Basavaraju, Sekhara Rao; Easterly, Clay E.

    2002-01-01

    Radiation therapy while important in the management of several diseases, is implicated in the causation of atherosclerosis and other cardiovascular complications. Cancer and atherosclerosis go through the same stages of initiation, promotion, and complication, beginning with a mutation in a single cell. Clinical observations before the 1960s lead to the belief that the heart is relatively resistant to the doses of radiation used in radiotherapy. Subsequently, it was discovered that the heart is sensitive to radiation and many cardiac structures may be damaged by radiation exposure. A significantly higher risk of death due to ischemic heart disease has been reported for patients treated with radiation for Hodgkin's disease and breast cancer. Certain cytokines and growth factors, such as TGF-β1 and IL-1 β, may stimulate radiation-induced endothelial proliferation, fibroblast proliferation, collagen deposition, and fibrosis leading to advanced lesions of atherosclerosis. The treatment for radiation-induced ischemic heart disease includes conventional pharmacological therapy, balloon angioplasty, and bypass surgery. Endovascular irradiation has been shown to be effective in reducing restenosis-like response to balloon-catheter injury in animal models. Caution must be exercised when radiation therapy is combined with doxorubicin because there appears to be a synergistic toxic effect on the myocardium. Damage to endothelial cells is a central event in the pathogenesis of damage to the coronary arteries. Certain growth factors that interfere with the apoptotic pathway may provide new therapeutic strategies for reducing the risk of radiation-induced damage to the heart. Exposure to low level occupational or environmental radiation appears to pose no undue risk of atherosclerosis development or cardiovascular mortality. But, other radiation-induced processes such as the bystander effects, abscopal effects, hormesis, and individual variations in radiosensitivity may be

  14. Combined effects of radiation and other agents on the stomach cancer incidence among Mayak Atomic Plant workers

    International Nuclear Information System (INIS)

    Zhuntova, G.V.; Tokarskaya, Z.B.; Belyaeva, Z.D.; Rovny, S.I.; Sirchikov, V.A.

    2000-01-01

    The gravity of a problem of the combined action of radiation and other factors again was confirmed sessions UNSCEAR in May, 1998. It especially is important at study of cancer diseases in connection with the polyetiology and multistage of them development. The estimation of radiation, medico-biological factors and condition of life in occurrence of a stomach cancer among Mayak personnel was specified by case-cohort research. For a quota 503 men (157 cases of a stomach cancer, 346 men of the healthy personnel) attributive risk of the radiation factors was 8.8%, medico-biological - 57,2% (from them by greatest was influence chronic gastritis with secreting insufficiency - 35.4%), tobacco consumption - 31,6%. At an estimation of risk of a stomach cancer depending on external γ-irradiation best fitting was received at use of square-law model. The excess relative risk was 0,27 Gr -2 (F=44,5; P=0,007). For 239 Pu incorporation was not revealed of distinct connection with stomach cancer incidences. Interaction of the radiation and non-radiation factors also was appreciated. The interaction of gastritis with external γ-irradiation or 239 Pu was multiplicate. The interaction of smoking with γ-irradiation or 239 Pu incorporation was multiplicate also. The distribution histological types of a stomach cancer among the workers of Mayak plant differed in comparison with not working. Among the workers the increase poorly differentiated adenocarcinoma was observed. (author)

  15. Combined effects of radiation and other agents on the stomach cancer incidence among Mayak Atomic Plant workers

    Energy Technology Data Exchange (ETDEWEB)

    Zhuntova, G.V.; Tokarskaya, Z.B.; Belyaeva, Z.D. [Branch No 1 of State Research Center of Public Health Ministry of the Russian Federation, Ozyorsk (Russian Federation). Biophysics Inst.; Rovny, S.I.; Sirchikov, V.A.

    2000-05-01

    The gravity of a problem of the combined action of radiation and other factors again was confirmed sessions UNSCEAR in May, 1998. It especially is important at study of cancer diseases in connection with the polyetiology and multistage of them development. The estimation of radiation, medico-biological factors and condition of life in occurrence of a stomach cancer among Mayak personnel was specified by case-cohort research. For a quota 503 men (157 cases of a stomach cancer, 346 men of the healthy personnel) attributive risk of the radiation factors was 8.8%, medico-biological - 57,2% (from them by greatest was influence chronic gastritis with secreting insufficiency - 35.4%), tobacco consumption - 31,6%. At an estimation of risk of a stomach cancer depending on external {gamma}-irradiation best fitting was received at use of square-law model. The excess relative risk was 0,27 Gr{sup -2} (F=44,5; P=0,007). For {sup 239}Pu incorporation was not revealed of distinct connection with stomach cancer incidences. Interaction of the radiation and non-radiation factors also was appreciated. The interaction of gastritis with external {gamma}-irradiation or {sup 239}Pu was multiplicate. The interaction of smoking with {gamma}-irradiation or {sup 239}Pu incorporation was multiplicate also. The distribution histological types of a stomach cancer among the workers of Mayak plant differed in comparison with not working. Among the workers the increase poorly differentiated adenocarcinoma was observed. (author)

  16. Higher order monochromatic aberrations of the human infant eye

    OpenAIRE

    Wang, Jingyun; Candy, T. Rowan

    2005-01-01

    The monochromatic optical aberrations of the eye degrade retinal image quality. Any significant aberrations during postnatal development could contribute to infants’ immature visual performance and provide signals for the control of eye growth. Aberrations of human infant eyes from 5 to 7 weeks old were compared with those of adult subjects using a model of an adultlike infant eye that accounted for differences in both eye and pupil size. Data were collected using the COAS Shack-Hartmann wave...

  17. Photofission of NAT Pt by monochromatic and polarized photons in the quasi-deuteron region

    International Nuclear Information System (INIS)

    Paiva, Eduardo de.

    1992-01-01

    The measurement of the Nat Pt photofission yield at 69 MeV of effective average energy of the incident photon is made using a polarized and monochromatic photon beam from the LADON system of the National Laboratory of Frascati, Italy, produced by inverse Compton scattering of laser light by high energy electrons of the ADONE Accelerator and using as fission track solid detector the Makrofol, being the developing made by usual procedure. The experimental value of the nuclear fissionability is compared to a theoretical value obtained following a model at two stages: in the first, the photon energy is absorbed by a neutron-proton pair inducing to the nucleus excitation, and in the second the nucleus de-excites due to the competition between nucleon evaporation and fission. The effect of fast nucleon emission during the first stage and the successive evaporation of neutrons in the second stage are considered. 40 refs, 12 figs, 9 tabs

  18. Developing Multivariable Normal Tissue Complication Probability Model to Predict the Incidence of Symptomatic Radiation Pneumonitis among Breast Cancer Patients.

    Directory of Open Access Journals (Sweden)

    Tsair-Fwu Lee

    Full Text Available Symptomatic radiation pneumonitis (SRP, which decreases quality of life (QoL, is the most common pulmonary complication in patients receiving breast irradiation. If it occurs, acute SRP usually develops 4-12 weeks after completion of radiotherapy and presents as a dry cough, dyspnea and low-grade fever. If the incidence of SRP is reduced, not only the QoL but also the compliance of breast cancer patients may be improved. Therefore, we investigated the incidence SRP in breast cancer patients after hybrid intensity modulated radiotherapy (IMRT to find the risk factors, which may have important effects on the risk of radiation-induced complications.In total, 93 patients with breast cancer were evaluated. The final endpoint for acute SRP was defined as those who had density changes together with symptoms, as measured using computed tomography. The risk factors for a multivariate normal tissue complication probability model of SRP were determined using the least absolute shrinkage and selection operator (LASSO technique.Five risk factors were selected using LASSO: the percentage of the ipsilateral lung volume that received more than 20-Gy (IV20, energy, age, body mass index (BMI and T stage. Positive associations were demonstrated among the incidence of SRP, IV20, and patient age. Energy, BMI and T stage showed a negative association with the incidence of SRP. Our analyses indicate that the risk of SPR following hybrid IMRT in elderly or low-BMI breast cancer patients is increased once the percentage of the ipsilateral lung volume receiving more than 20-Gy is controlled below a limitation.We suggest to define a dose-volume percentage constraint of IV20< 37% (or AIV20< 310cc for the irradiated ipsilateral lung in radiation therapy treatment planning to maintain the incidence of SPR below 20%, and pay attention to the sequelae especially in elderly or low-BMI breast cancer patients. (AIV20: the absolute ipsilateral lung volume that received more than

  19. Effect of γ-radiation on the incidence of plant tumors (to the problem of carcinogenesis)

    International Nuclear Information System (INIS)

    Kuzin, A.M.; Yurov, S.S.; Vagabova, M.Eh.; Shchelkaeva, N.V.

    1986-01-01

    In experiments on two plant species: of Kalanchoe diagremontiana and potato (Solanum tuberosum) it was shown that γ-irradiation of the plant tissues, before infecting with Ti-plasmide Agrobacterium tumefaciens C-58, with doses stimulating the development of the plants markedly increases the incidence of tumors, promotes their growth, and increases the probability of inverse differentiation of tumor cells

  20. Unstructured-Mesh Terrain Analysis and Incident Solar Radiation for Continuous Hydrologic Modeling in Mountain Watersheds

    Directory of Open Access Journals (Sweden)

    Hernan A. Moreno

    2018-03-01

    Full Text Available This article presents a methodology for estimating total incoming solar radiation from Triangular Irregular Network (TIN topographic meshes. The algorithm also computes terrain slope degree and aspect (slope orientation and accounts for self shading and cast shadows, sky view fractions for diffuse radiation, remote albedo and atmospheric backscattering, by using a vectorial approach within a topocentric coordinate system establishing geometric relations between groups of TIN elements and the sun position. A normal vector to the surface of each TIN element describes its slope and aspect while spherical trigonometry allows computing a unit vector defining the position of the sun at each hour and day of the year. Sky view fraction, useful to determine diffuse and backscattered radiation, is computed for each TIN element at prescribed azimuth intervals targeting the steepest elevation gradient. A comparison between the sun zenith angle and the steepest gradient allows deciding whether or not the pivot element is shaded. Finally, remote albedo is computed from the sky view fraction complementary functions for observed albedo values of the surrounding terrain. The sensitivity of the different radiative components to seasonal changes in atmospheric transmissivitties and surrounding albedo is tested in a mountainous watershed in Wyoming. This methodology represents an improvement on the current algorithms to compute terrain and radiation values on unstructured-mesh terrain models. All terrain-related features (e.g., slope, aspect, sky view fraction can be pre-computed and stored for easy access into a subsequent, progressive-in-time, numerical simulation.

  1. Monochromatic radiography of high energy density physics experiments on the MAGPIE generator.

    Science.gov (United States)

    Hall, G N; Burdiak, G C; Suttle, L; Stuart, N H; Swadling, G F; Lebedev, S V; Smith, R A; Patankar, S; Suzuki-Vidal, F; de Grouchy, P; Harvey-Thompson, A J; Bennett, M; Bland, S N; Pickworth, L; Skidmore, J

    2014-11-01

    A monochromatic X-ray backlighter based on Bragg reflection from a spherically bent quartz crystal has been developed for the MAGPIE pulsed power generator at Imperial College (1.4 MA, 240 ns) [I. H. Mitchell et al., Rev. Sci. Instrum. 67, 1533 (2005)]. This instrument has been used to diagnose high energy density physics experiments with 1.865 keV radiation (Silicon He-α) from a laser plasma source driven by a ∼7 J, 1 ns pulse from the Cerberus laser. The design of the diagnostic, its characterisation and performance, and initial results in which the instrument was used to radiograph a shock physics experiment on MAGPIE are discussed.

  2. Automatic Suppression of Intense Monochromatic Light in Electro-Optical Sensors

    Science.gov (United States)

    Ritt, Gunnar; Eberle, Bernd

    2012-01-01

    Electro-optical imaging sensors are widely distributed and used for many different tasks. Due to technical improvements, their pixel size has been steadily decreasing, resulting in a reduced saturation capacity. As a consequence, this progress makes them susceptible to intense point light sources. Developments in laser technology have led to very compact and powerful laser sources of any wavelength in the visible and near infrared spectral region, offered as laser pointers. The manifold of wavelengths makes it difficult to encounter sensor saturation over the complete operating waveband by conventional measures like absorption or interference filters. We present a concept for electro-optical sensors to suppress overexposure in the visible spectral region. The key element of the concept is a spatial light modulator in combination with wavelength multiplexing. This approach allows spectral filtering within a localized area in the field of view of the sensor. The system offers the possibility of automatic reduction of overexposure by monochromatic laser radiation. PMID:23202039

  3. Radiation factors and smoking interaction at lung cancer incidence for workers at a nuclear enterprise

    International Nuclear Information System (INIS)

    Tokarskaya, Z.B.; Khokhryakov, V.F.; Okladnikova, N.D.; Belyaeva, Z.D.; Zhuntova, G.V.

    1997-01-01

    It was shown on the basis of retrospective investigation of 500 workers at a nuclear enterprise (162 cases of lung cancer, 338 persons as matching control) that the interaction of external gamma-irradiation (> 2.0 Gy) and the body - burden of 239 Pu (> 9.3 kBq) at lung cancer is characterized as the multiplicative effect. Combined influence of smoking and radiation factors dependent on smoking index (SI): it changed from additive up to multiplicative and than to antagonistic with the increase of the smoking effect. The received results could be explained on the basis of a two - mutation model of radiation carcinogenesis

  4. Ionizing radiation increases primary cilia incidence and induces multiciliation in C2C12 myoblasts

    Czech Academy of Sciences Publication Activity Database

    Filipová, A.; Diaz-Garcia, D.; Bezrouk, A.; Čížková, D.; Havelek, R.; Vávrová, J.; Dayanithi, Govindan; Řezáčová, M.

    2015-01-01

    Roč. 39, č. 8 (2015), s. 943-953 ISSN 1065-6995 Institutional support: RVO:68378041 Keywords : cell line * ionizing radiation * multiple cilia * myoblast * primary cilium * serum starvation stress Subject RIV: FP - Other Medical Disciplines Impact factor: 1.663, year: 2015

  5. Imaging radiation pneumonitis in a rat model of a radiological terrorism incident

    Science.gov (United States)

    Molthen, Robert; Wu, QingPing; Krenz, Gary; Medhora, Meetha; Jacobs, Elizabeth; Moulder, John E.

    2009-02-01

    We have developed a rat model of single, sub-lethal thoracic irradiation. Our irradiation protocol is considered representative of exposures near the detonation site of a dirty bomb or small nuclear device. The model is being used to investigate techniques for identifying, triaging and treating possible victims. In addition to physiological markers of right ventricular hypertrophy, pulmonary vascular resistance, and arterial distensibility, we present two methods for quantifying microvascular density. We used methods including microfocal X-ray imaging to investigate changes in lung structure/function resulting from radiation exposure. Radiation pneumonitis is a complication in subjects receiving thoracic irradiation. A radiographic hallmark of acute radiation pneumonitis is a diffuse infiltrate corresponding to the radiation treatment field. We describe two methods for quantifying small artery dropout that occurs in the model at the same time-period. Rats were examined 3-days, 2-weeks, 1-month (m), 2-m, 5-m, and 12-m post-irradiation and compared with aged-matched controls. Right ventricular hypertrophy and increases in pulmonary vascular resistance were present during the pneumonitis phase. Vascular injury was dependent on dose and post-irradiation duration. Rats irradiated with 5 Gy had few detectable changes, whereas 10 Gy resulted in a significant decrease in both microvascular density and arterial distensibility around 2- m, the decrease in each lessening, but extending through 12-m. In conclusion, rats irradiated with a 10 Gy dose had changes in vascular structure concurrent with the onset of radiation pneumonitis that were detectable with our imaging techniques and these structural changes persist after resolution of the pneumonitis.

  6. Thyroid cancer incidence in iodine deficient areas exposed to radiation after Chernobyl accident

    International Nuclear Information System (INIS)

    Szybinski, Z.; Mazurek-Przybylik, E.

    1996-01-01

    In two districts of Southern Poland; Krakow and Nowy Sacz (2 million people), standardized thyroid cancer incidence rate IR was evaluated from 1976 to 1992. This area was classified as a moderate iodine deficiency endemic goiter region and belonged to the most contaminated areas in Poland after Chernobyl accident. Recalculated - in terms of real iodine intake-thyroid commitment equivalent dose in the youngest age groups reached 100 mSv. The aim of the study was to evaluate, 6 years after Chernobyl accident, thyroid cancer incidence rate and histotype. Age and sex specific incidence rate in Krakow for male was 0.827 and for female 3.093 and 0.93 and 2.164 for Nowy Sacz respectively. There was no increase of IR in the group of age 0-19 yrs, however in the group over 44 yrs in females in the period of time 1989-1992 significant increase of follicular cancer was observed. In the histotype, the follicular cancerpredominated over the papillary one: 42,9% against 33,6%. Predominance of the follicular cancer is typical for iodine deficient area. Significant increase of the follicular cancer may be due to the increase of iodine deficiency. (author). 14 refs, 1 fig., 5 tabs

  7. Acoustic radiation force due to arbitrary incident fields on spherical particles in soft tissue

    Energy Technology Data Exchange (ETDEWEB)

    Treweek, Benjamin C., E-mail: btreweek@utexas.edu; Ilinskii, Yurii A.; Zabolotskaya, Evgenia A.; Hamilton, Mark F. [Applied Research Laboratories, The University of Texas at Austin, P.O. Box 8029, Austin, TX 78713-8029 (United States)

    2015-10-28

    Acoustic radiation force is of interest in a wide variety of biomedical applications ranging from tissue characterization (e.g. elastography) to tissue treatment (e.g. high intensity focused ultrasound, kidney stone fragment removal). As tissue mechanical properties are reliable indicators of tissue health, the former is the focus of the present contribution. This is accomplished through an investigation of the acoustic radiation force on a spherical scatterer embedded in tissue. Properties of both the scatterer and the surrounding tissue are important in determining the magnitude and the direction of the force. As these properties vary, the force computation shows changes in magnitude and direction, which may enable more accurate noninvasive determination of tissue properties.

  8. Preliminary studies into profiling DNA recovered from a radiation or radioactivity incident

    International Nuclear Information System (INIS)

    Hodgson, A.; Baxter, A.

    2013-01-01

    The examination and profiling of human DNA recovered from a scene of crime is an essential aspect of criminal investigations. However, it is currently not known whether DNA recovered from a scene where an ionising radiation source or radioactive contamination is present can be successfully profiled. The direct examination and analysis of radioactively contaminated DNA has not been widely explored using the current procedures employed by forensic service providers. As a result, AWE is putting in place an extensive research and development programme to better understand the effects that radiation has on the ability to profile human DNA, and assess the associated retention of different radioactive contaminants within each step of the profiling procedure. A summary will be provided on the aims of this project and progress that has been made to date; together with a discussion of the lessons that have been learnt during the course of the programme's development. (author)

  9. Accidents and incidents with external and/or internal radiation-exposure

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    An individual radiation exposure accident is an unexpected and unintended event which gives rise to an overexposure (external or internal). By overexposure one means all external or internal exposure which could lead to the exceeding of the regulatory norms. Going beyond these limits does not always produce pathological manifestations. The term radiological accident is, in practice, used only when there is an occurrence of some biological or clinical response, or when some therapeutic action is required. A radio-exposure accident can occur: within or from a nuclear power plant or from a center employing ionizing radiation. These are the most frequent; and during the transport of radioactive materials. These are exceptional events. The tanks and containers used in the transport of highly radioactive substances are exhaustively studied for their resistance to accidents, and the conditions of transport determined by very strict national and international regulations. The transport of substances of low radioactivity (labelled molecules, radiopharmaceuticals...) carries only minor risks

  10. Study and production of polarized monochromatic thermal neutron beams

    International Nuclear Information System (INIS)

    Beiln, H.

    1963-06-01

    Results obtained with a recently built neutron spectrometer producing monochromatic polarized neutron beams,in the energy rang (10 -3 - 10) eV and using a series of artificial (Co: 92 per cent - Fe: 8 per cent) monocrystal as polarizers and analysers, are given. A high precision method for cutting monocrystals is explained. A description of the installation itself as well as some results obtained with Fe 3 O 4 crystals are also given. Experimental result pertaining to various magnetic guide and 'spin flip' system, as required in the handling of such polarized neutron beams, are also discussed. (author) [fr

  11. A radiation contamination incident involving strontium 90 in a private home

    International Nuclear Information System (INIS)

    Fleischmann, A.W.; Button, J.C.E.

    1977-01-01

    In October 1975 a private electronic service contractor, operating in his home workshop, drilled a hole through a Strontium 90 (15 mCi) capsule while attempting to repair a thickness gauge. Four days passed before he became aware of the resultant contamination and notified the authorities. Contamination was spead over himself, his wife, the family pet (a dog), the wokshop and living area of his home, furniture, garden and paths around the house. It took four officers from the Health Commission of New South Wales and another four from the Australian Atomic Energy Commission four weeks to clean the home and surrounds to the levels where the premises would be again occupied. A large amount of electronic equipment, personal belongings and furniture could not be decontaminated and has had to be stored for ultimate disposal. This, in itself, represents a problem because there is no Australian waste burial site and some of the objects, for disposal, are relatively large (e.g. carpets, pieces of furniture, furniture covers, etc.) It is proposed to discuss the incident, decontamination, health aspects and some of the consequences of the incident

  12. Epidemiological studies on disturbances of human fetal development in areas with various doses of natural background radiation. I. Relationship between incidences of Down's syndrome or visible malformation and gonad dose equivalent rate of natural background radiation

    International Nuclear Information System (INIS)

    Ujeno, Y.

    1985-01-01

    The relationship between environmental radiation to the gonads and incidences of Down's syndrome and visible malformation was analyzed using Kendall's rank correlation method. The subjects, studied during a 3-yr period (1979-1981), were inhabitants of 46 prefectures in Japan that had various dose rates of natural background ionizing radiation. Results showed that the natural background very low-dose radiation rate was not a predominant factor responsible for inducing Down's syndrome or other visible malformations

  13. Correlation between the time-series of air temperature and incident solar radiation at Port Harcourt, Nigeria

    International Nuclear Information System (INIS)

    Adjepong, S.K.; Okujagu, C.

    1987-12-01

    We present the preliminary results of an investigation of the correlation between the temporal variations of the time-series of ground air temperature and incident solar radiation recorded at Port Harcourt (lat. 4 deg. 51' N, long. 7 deg. 01' E), Nigeria, during a five-year period (1981 through 1985). Computed cross-correlation functions of the daily time-series reveal correlation at time lags which are approximate harmonics of the 27-day solar rotation cycle. The cross-correlation function of the mean monthly series shows correlation at a time lag of 12 months implying a dominant annual-cycle component in the variation of either series. (author). 12 refs, 2 figs

  14. Use of risk projection models to estimate mortality and incidence from radiation-induced breast cancer in screening programs

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, M [Chemical and Nuclear Engineering Department, Polytechnic University of Valencia, Camino de Vera s/n 46022 Valencia (Spain); Ferrer, S [Chemical and Nuclear Engineering Department, Polytechnic University of Valencia, Camino de Vera s/n 46022 Valencia (Spain); Villaescusa, J I [Radiation Protection Service, Hospital Universitario La Fe, Avda Campanar, 21 46009 Valencia (Spain); Verdu, G [Chemical and Nuclear Engineering Department, Polytechnic University of Valencia, Camino de Vera s/n 46022 Valencia (Spain); Salas, M D [Public Health General Direction, Conselleria de Sanitat de Valencia, C/Micer Masco, 31 46021 Valencia (Spain); Cuevas, M D [Assistential Service General Direction, Conselleria de Sanitat de Valencia, C/Micer Masco, 31 46021 Valencia (Spain)

    2005-02-07

    The authors report on a method to calculate radiological risks, applicable to breast screening programs and other controlled medical exposures to ionizing radiation. In particular, it has been applied to make a risk assessment in the Valencian Breast Cancer Early Detection Program (VBCEDP) in Spain. This method is based on a parametric approach, through Markov processes, of hazard functions for radio-induced breast cancer incidence and mortality, with mean glandular breast dose, attained age and age-at-exposure as covariates. Excess relative risk functions of breast cancer mortality have been obtained from two different case-control studies exposed to ionizing radiation, with different follow-up time: the Canadian Fluoroscopy Cohort Study (1950-1987) and the Life Span Study (1950-1985 and 1950-1990), whereas relative risk functions for incidence have been obtained from the Life Span Study (1958-1993), the Massachusetts tuberculosis cohorts (1926-1985 and 1970-1985), the New York post-partum mastitis patients (1930-1981) and the Swedish benign breast disease cohort (1958-1987). Relative risks from these cohorts have been transported to the target population undergoing screening in the Valencian Community, a region in Spain with about four and a half million inhabitants. The SCREENRISK software has been developed to estimate radiological detriments in breast screening. Some hypotheses corresponding to different screening conditions have been considered in order to estimate the total risk associated with a woman who takes part in all screening rounds. In the case of the VBCEDP, the total radio-induced risk probability for fatal breast cancer is in a range between [5 x 10{sup -6}, 6 x 10{sup -4}] versus the natural rate of dying from breast cancer in the Valencian Community which is 9.2 x 10{sup -3}. The results show that these indicators could be included in quality control tests and could be adequate for making comparisons between several screening programs.

  15. Use of risk projection models to estimate mortality and incidence from radiation-induced breast cancer in screening programs

    International Nuclear Information System (INIS)

    Ramos, M; Ferrer, S; Villaescusa, J I; Verdu, G; Salas, M D; Cuevas, M D

    2005-01-01

    The authors report on a method to calculate radiological risks, applicable to breast screening programs and other controlled medical exposures to ionizing radiation. In particular, it has been applied to make a risk assessment in the Valencian Breast Cancer Early Detection Program (VBCEDP) in Spain. This method is based on a parametric approach, through Markov processes, of hazard functions for radio-induced breast cancer incidence and mortality, with mean glandular breast dose, attained age and age-at-exposure as covariates. Excess relative risk functions of breast cancer mortality have been obtained from two different case-control studies exposed to ionizing radiation, with different follow-up time: the Canadian Fluoroscopy Cohort Study (1950-1987) and the Life Span Study (1950-1985 and 1950-1990), whereas relative risk functions for incidence have been obtained from the Life Span Study (1958-1993), the Massachusetts tuberculosis cohorts (1926-1985 and 1970-1985), the New York post-partum mastitis patients (1930-1981) and the Swedish benign breast disease cohort (1958-1987). Relative risks from these cohorts have been transported to the target population undergoing screening in the Valencian Community, a region in Spain with about four and a half million inhabitants. The SCREENRISK software has been developed to estimate radiological detriments in breast screening. Some hypotheses corresponding to different screening conditions have been considered in order to estimate the total risk associated with a woman who takes part in all screening rounds. In the case of the VBCEDP, the total radio-induced risk probability for fatal breast cancer is in a range between [5 x 10 -6 , 6 x 10 -4 ] versus the natural rate of dying from breast cancer in the Valencian Community which is 9.2 x 10 -3 . The results show that these indicators could be included in quality control tests and could be adequate for making comparisons between several screening programs

  16. The incidence of radiation necrosis following stereotactic radiotherapy for melanoma brain metastases: the potential impact of immunotherapy.

    Science.gov (United States)

    Kaidar-Person, Orit; Zagar, Timothy M; Deal, Allison; Moschos, Stergios J; Ewend, Matthew G; Sasaki-Adams, Deanna; Lee, Carrie B; Collichio, Frances A; Fried, David; Marks, Lawrence B; Chera, Bhishamjit S

    2017-07-01

    Stereotactic radiotherapy (SRT) is the standard treatment for patients with limited number of brain metastases. In the past few years, newer immunotherapies (immune checkpoint inhibitors) have been proven to prolong survival in patients with metastatic melanoma. The safety of the combination of SRT and immunotherapy for brain metastases is unknown. We retrospectively identified patients with melanoma brain metastases treated with SRT between 2007 and 2015. Patients who did not have at least 3 months of follow-up with imaging after SRT were excluded from the analysis. Outcomes were compared between patients who were treated with or without immunotherapy. A total of 58 patients were included; of these, 29 were treated with SRT and immunotherapy. MAPK inhibitors (BRAF, MEK inhibitors) were used more often in the immunotherapy group (nine vs. two patients). There was a higher incidence of intracranial complications in patients treated with immunotherapy and SRT. Eight patients had radiation necrosis; all occurred in patients who were treated with immunotherapy. Nine patients had hemorrhage, of which seven occurred in patients who were treated with immunotherapy (P=0.08). However, patients treated with immunotherapy and SRT had a significant overall survival advantage compared with SRT without immunotherapy (15 vs. 6 months, P=0.0013). Patients treated with SRT and immunotherapy have a higher incidence/risk of intracranial complications, but a longer overall survival.

  17. Estimating incident ultraviolet radiation exposure in the northern Gulf of Mexico during the Deepwater Horizon oil spill.

    Science.gov (United States)

    Bridges, Kristin N; Lay, Claire R; Alloy, Matthew M; Gielazyn, Michel L; Morris, Jeffrey M; Forth, Heather P; Takeshita, Ryan; Travers, Constance L; Oris, James T; Roberts, Aaron P

    2018-02-23

    Millions of barrels of oil were released into the Gulf of Mexico following the 2010 explosion of the Deepwater Horizon oil rig. Polycyclic aromatic hydrocarbons (PAHs) are toxic components of crude oil, which may become more toxic in the presence of ultraviolet (UV) radiation, a phenomenon known as photo-induced toxicity. The Deepwater Horizon spill impacted offshore and estuarine sites, where biota may be co-exposed to UV and PAHs. Penetration of UV into the water column is affected by site-specific factors. Therefore, measurements and/or estimations of UV are necessary when one is assessing the risk to biota posed by photo-induced toxicity. We describe how estimates of incident UV were determined for the area impacted by the Deepwater Horizon oil spill, using monitoring data from radiometers near the spill, in conjunction with reference spectra characterizing the composition of solar radiation. Furthermore, we provide UV attenuation coefficients for both near- and offshore sites in the Gulf of Mexico. These estimates are specific to the time and location of the spill, and fall within the range of intensities utilized during photo-induced toxicity tests performed in support of the Deepwater Horizon Natural Resource Damage Assessment (NRDA). These data further validate the methodologies and findings of phototoxicity tests included in the Deepwater Horizon NRDA, while underscoring the importance of considering UV exposure when assessing possible risks following oil spills. Environ Toxicol Chem 2018;9999:1-9. © 2018 SETAC. © 2018 SETAC.

  18. Earth Reflected Solar Radiation Incident upon an Arbitrarily Oriented Spinning Flat Plate

    Science.gov (United States)

    Cunningham, Fred G.

    1963-01-01

    A general derivation is given for the earth reflected solar radiation input to a flat plate--a solar cell paddle, for example--which is spinning about an axis coincident with the axis of symmetry of the satellite to which it is affixed. The resulting equations are written for the general case so that arbitrary orientations of the spin axis with respect to the earth-satellite line and arbitrary orientations of the normal to the plate with respect to the spin axis can be treated. No attempt is made to perform the resulting integrations because of the complexity of the equations; nor is there any attempt to delineate the integration limits for the general case. However, the equations governing these limits are given. The appendixes contain: the results, in graphical form, of two representative examples; the general computer program for the calculation is given in Fortran notation; and the results of a calculation of the distribution of albedo energy on the proposed Echo II satellite. The value of the mean solar constant used is 1.395 times 10 (sup 4) ergs per centimeters-squared per second; the mean albedo of the earth is assumed to be 0.34; and the earth is assumed to be a diffuse reflector.

  19. Incident particle range dependence of radiation damage in a power bipolar junction transistor

    Science.gov (United States)

    Liu, Chao-Ming; Li, Xing-Ji; Geng, Hong-Bin; Rui, Er-Ming; Guo, Li-Xin; Yang, Jian-Qun

    2012-10-01

    The characteristic degradations in silicon NPN bipolar junction transistors (BJTs) of type 3DD155 are examined under the irradiations of 25-MeV carbon (C), 40-MeV silicon (Si), and 40-MeV chlorine (Cl) ions respectively. Different electrical parameters are measured in-situ during the exposure of heavy ions. The experimental data shows that the changes in the reciprocal of the gain variation (Δ(1/β)) of 3DD155 transistors irradiated respectively by 25-MeV C, 40-MeV Si, and 40-MeV Cl ions each present a nonlinear behaviour at a low fluence and a linear response at a high fluence. The Δ(1/β) of 3DD155 BJT irradiated by 25-MeV C ions is greatest at a given fluence, a little smaller when the device is irradiated by 40-MeV Si ions, and smallest in the case of the 40-MeV Cl ions irradiation. The measured and calculated results clearly show that the range of heavy ions in the base region of BJT affects the level of radiation damage.

  20. Intersexual variation in the foraging ecology of sexually monochromatic Western Wood-Pewees

    Science.gov (United States)

    Alissa M. Fogg; T. Luke George; Kathryn L. Purcell

    2013-01-01

    Investigators generally pool observations of males and females in studies of the foraging behavior of sexually monochromatic songbirds. However, such pooling can obscure possible intersexual differences. We compared the foraging behavior of male and female Western Wood-Pewees (Contopus sordidulus), a sexually monochromatic species, in the Sierra...

  1. High resolution, monochromatic x-ray topography capability at CHESS

    Energy Technology Data Exchange (ETDEWEB)

    Finkelstein, K. D., E-mail: kdf1@cornell.edu; Pauling, A.; Brown, Z. [CHESS, Cornell University, Ithaca, NY (United States); Jones, R. [Department of Physics, University of Connecticut, Storrs, CT (United States); Tarun, A.; Misra, D. S. [IIa Technologies (Singapore); Jupitz, S. [St. Mary’s College of Maryland, St. Mary’s City, MD (United States); Sagan, D. C. [CLASSE, Cornell University, Ithaca, NY (United States)

    2016-07-27

    CHESS has a monochromatic x-ray topography capability serving continually expanding user interest. The setup consists of a beam expanding monochromator, 6-circle diffactometer, and CHESS designed CMOS camera with real time sample-alignment capability. This provides rocking curve mapping with angle resolution as small as 2 µradians, spatial resolution to 3 microns, and field of view up to 7mm. Thus far the capability has been applied for: improving CVD-diamond growth, evaluating perfection of ultra-thin diamond membranes, correlating performance of diamond-based electronics with crystal defect structure, and defect analysis of single crystal silicon carbide. This paper describes our topography system, explains its capabilities, and presents experimental results from several applications.

  2. High resolution, monochromatic x-ray topography capability at CHESS

    International Nuclear Information System (INIS)

    Finkelstein, K. D.; Pauling, A.; Brown, Z.; Jones, R.; Tarun, A.; Misra, D. S.; Jupitz, S.; Sagan, D. C.

    2016-01-01

    CHESS has a monochromatic x-ray topography capability serving continually expanding user interest. The setup consists of a beam expanding monochromator, 6-circle diffactometer, and CHESS designed CMOS camera with real time sample-alignment capability. This provides rocking curve mapping with angle resolution as small as 2 µradians, spatial resolution to 3 microns, and field of view up to 7mm. Thus far the capability has been applied for: improving CVD-diamond growth, evaluating perfection of ultra-thin diamond membranes, correlating performance of diamond-based electronics with crystal defect structure, and defect analysis of single crystal silicon carbide. This paper describes our topography system, explains its capabilities, and presents experimental results from several applications.

  3. Quasi-monochromatic parallel radiography utilizing a computed radiography system

    International Nuclear Information System (INIS)

    Sato, E.; Hayasi, Y.; Germer, R.; Tanaka, E.; Mori, H.; Kawai, T.; Ichimaru, T.; Sato, S.; Takayama, K.; Ido, H.

    2004-01-01

    A fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a copper-target X-ray tube is described. The X-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an X-ray tube. The negative high-voltage is applied to the cathode electrode, and the anode electrode is connected to the ground. In this experiment, the tube voltage was regulated from12-25 kV, and the tube current was regulated within 3.0 mA by the filament temperature. The exposure time was controlled in order to obtain optimum X-ray intensity, and the maximum focal spot dimensions were approximately 2 mmx1.5 mm. The polycapillary plate was J5022-21 (Hamamatsu Photonics Inc.), and the plate thickness was 1.0 mm. The outer, effective, and hole diameters were 87 mm, 77 mm, and 25 μm, respectively. Quasi-monochromatic X-rays were produced using a 10 μm-thick copper filter, and these rays were formed into parallel beams by the polycapillary, and the radiogram was taken using a computed radiography system utilizing imaging plates. In the measurement of image resolution, the resolution fell according to increases in the distance between the chart and imaging plate using a polycapillary. We could observe a 50 μm tungsten wire clearly, and fine blood vessels of approximately 100 μm were visible in angiography

  4. Training of an incidence of radiation on surfaces by vectorial representation; Didactica del analisis de la incidencia de radiacion solar mediante una representacion vectorial

    Energy Technology Data Exchange (ETDEWEB)

    Luis, F. J. de; Perez-Garcia, M.; Barbero, F. J.; Batlles, F. J.

    2004-07-01

    This work gathers and it exposes a set of educational contents extracted from the general bibliography and from the own experience in Engineering studies and courses on the application of a vector representation to the description of the apparent movement of the sun, the shading evaluation and the incidence of radiation on surfaces. (Author)

  5. Measurement of the radiation incident on ALS NdFeB permanent magnet insertion device structures and a determination of their lifetime

    International Nuclear Information System (INIS)

    Krebs, G.F.; Holmes, M.

    1997-05-01

    Measurements of the radiation incident on ALS insertion device NdFeB permanent magnet structures were carried out using thermoluminescence dosimeters. A plastic scintillator gamma telescope was utilized to unravel the various contributions to the integrated dose. Magnet lifetimes were calculated for various operational conditions

  6. Evaluation of the Reanalysis Surface Incident Shortwave Radiation Products from NCEP, ECMWF, GSFC, and JMA Using Satellite and Surface Observations

    Directory of Open Access Journals (Sweden)

    Xiaotong Zhang

    2016-03-01

    Full Text Available Solar radiation incident at the Earth’s surface (Rs is an essential component of the total energy exchange between the atmosphere and the surface. Reanalysis data have been widely used, but a comprehensive validation using surface measurements is still highly needed. In this study, we evaluated the Rs estimates from six current representative global reanalyses (NCEP–NCAR, NCEP-DOE; CFSR; ERA-Interim; MERRA; and JRA-55 using surface measurements from different observation networks [GEBA; BSRN; GC-NET; Buoy; and CMA] (674 sites in total and the Earth’s Radiant Energy System (CERES EBAF product from 2001 to 2009. The global mean biases between the reanalysis Rs and surface measurements at all sites ranged from 11.25 W/m2 to 49.80 W/m2. Comparing with the CERES-EBAF Rs product, all the reanalyses overestimate Rs, except for ERA-Interim, with the biases ranging from −2.98 W/m2 to 21.97 W/m2 over the globe. It was also found that the biases of cloud fraction (CF in the reanalyses caused the overestimation of Rs. After removing the averaged bias of CERES-EBAF, weighted by the area of the latitudinal band, a global annual mean Rs values of 184.6 W/m2, 180.0 W/m2, and 182.9 W/m2 were obtained over land, ocean, and the globe, respectively.

  7. Fusion of colour and monochromatic images with edge emphasis

    Directory of Open Access Journals (Sweden)

    Rade M. Pavlović

    2014-02-01

    Full Text Available We propose a novel method to fuse true colour images with monochromatic non-visible range images that seeks to encode important structural information from monochromatic images efficiently but also preserve the natural appearance of the available true chromacity information. We utilise the β colour opponency channel of the lαβ colour as the domain to fuse information from the monochromatic input into the colour input by the way of robust grayscale fusion. This is followed by an effective gradient structure visualisation step that enhances the visibility of monochromatic information in the final colour fused image. Images fused using this method preserve their natural appearance and chromacity better than conventional methods while at the same time clearly encode structural information from the monochormatic input. This is demonstrated on a number of well-known true colour fusion examples and confirmed by the results of subjective trials on the data from several colour fusion scenarios. Introduction The goal of image fusion can be broadly defined as: the representation of visual information contained in a number of input images into a single fused image without distortion or loss of information. In practice, however, a representation of all available information from multiple inputs in a single image is almost impossible and fusion is generally a data reduction task.  One of the sensors usually provides a true colour image that by definition has all of its data dimensions already populated by the spatial and chromatic information. Fusing such images with information from monochromatic inputs in a conventional manner can severely affect natural appearance of the fused image. This is a difficult problem and partly the reason why colour fusion received only a fraction of the attention than better behaved grayscale fusion even long after colour sensors became widespread. Fusion method Humans tend to see colours as contrasts between opponent

  8. Isolated lung events following radiation for early stage breast cancer: incidence and predictors for primary lung vs metastatic breast cancer

    International Nuclear Information System (INIS)

    Van Buren, Teresa A; Harris, Jay R; Sugarbaker, David J; Schneider, Lindsey; Healey, Elizabeth A

    1995-01-01

    Purpose: 1) To define the incidence of isolated lung events in a cohort of women treated with conservative surgery (CS) and radiation therapy (RT) for early stage breast cancer. 2) Among such patients, to define the relative distribution of primary lung cancer, metastatic breast cancer, and indeterminate lesions; and to identify any predictors for a diagnosis of lung vs metastatic breast cancer. 3) To examine the cohort with respect to whether a higher than expected incidence of lung cancer is seen following breast irradiation. Materials and Methods: Between 1968 and 1986, 1865 patients with clinical stage I-II breast cancer were treated with CS and RT; the median follow-up for surviving patients is 129 months. The study population was limited to patients who developed a subsequent isolated lung event as the first site of distant disease. Isolated lung event was defined as disease limited to the thoracic cavity, without evidence of either uncontrolled local breast disease or metastatic disease elsewhere. Diagnosis of the lung event as a primary lung cancer, a metastatic breast lesion, or an indeterminate lesion was documented from the viewpoint of 1) the pathologic analysis and 2) the clinical impression at the time of the lung event. Results: Sixty six of the 1865 patients (3.5%) developed an isolated lung event. The relative distribution of the pathologic and clinical diagnoses is shown below: The 66 lung events were characterized either as a solitary pulmonary nodule (27), multiple nodules (23), pleural effusion alone (10), unknown (2), or miscellaneous other findings (4). Among the 47 patients for whom pathology was available, the diagnosis remained indeterminate for 24 (51%). For patients with a definitive pathologic diagnosis, 69% ((9(13))) of smokers had a new lung cancer compared to 20% ((2(10))) of non-smokers (p=0.036), and 67% ((10(15))) of patients with a solitary pulmonary nodule had lung cancer compared to 14% ((1(7))) for other lung presentations (p

  9. Absolute calibration of a cold and thermal neutron detector using monochromatic neutron beam

    Science.gov (United States)

    Choi, Jin Ha; Cude-Woods, Christopher; Ito, Takeyasu; Young, Albert

    2017-09-01

    Time of flight spectra for cold neutrons exiting the moderator volume of the LANSCE UCN source has been obtained using a commercial neutron scintillator, EJ-426, coupled to a Hamamatsu R1355. The absolute efficiency for this detector system was determined using a 37.4 meV (monochromatic) neutron beam from the Neutron Powder Diffraction Facility (NPDF) at North Carolina State University's PULSTAR reactor. We measured the absolute neutron flux at the NPDF through thin foil activation and explored threshold effects through analysis of the measured pulse height distribution for effectively pure neutron signals from the NPDF beam. Non-uniformity of the flux profile across the detector and the detection efficiency as a function of the point of incidence of neutrons on the scintillator was explored using a X-Y translation system to perform scans using either fixed or movable apertures. The results are generally consistent with our expectations for this system, and provide a quantitative assessment of the sensitivity of this system to cold and thermal neutrons. This project was funded by the National Science Foundation and the Department of Energy.

  10. Photobiological interactions of blue light and photosynthetic photon flux: effects of monochromatic and broad-spectrum light sources.

    Science.gov (United States)

    Cope, Kevin R; Snowden, M Chase; Bugbee, Bruce

    2014-01-01

    Photosynthesis (Pn) and photomorphogenesis (Pm) are affected by light quality, light intensity and photoperiod. Although blue light (BL) is necessary for normal development, it is less efficient in driving Pn than other wavelengths of photosynthetically active radiation. The effects of BL on Pm are highly species dependent. Here we report the interacting effects of BL and photosynthetic photon flux (PPF) on growth and development of lettuce, radish and pepper. We used light-emitting diode (LED) arrays to provide BL fractions from 11% to 28% under broad-spectrum white LEDs, and from 0.3% to 92% under monochromatic LEDs. All treatments were replicated three times at each of two PPFs (200 and 500 μmol m(-2) s(-1)). Other than light quality, environmental conditions were uniformly maintained across chambers. Regardless of PPF, BL was necessary to prevent shade-avoidance responses in radish and lettuce. For lettuce and radish, increasing BL reduced stem length, and for both species, there were significant interactions of BL with PPF for leaf expansion. Increasing BL reduced petiole length in radish and flower number in pepper. BL minimally affected pepper growth and other developmental parameters. Pepper seedlings were more photobiologically sensitive than older plants. Surprisingly, there were few interactions between monochromatic and broad-spectrum light sources. © 2013 The American Society of Photobiology.

  11. Properties of light transition radiation of 660 MeV proton inclined incidence (γ=1.7) on a thick nickel plate. II

    International Nuclear Information System (INIS)

    Zrelov, V.P.; Pavlovic, P.; Ruzicka, J.

    1975-01-01

    The basic properties of transition radiation in the visible fraction of the spectrum have been calculated for 660 MeV protons (γ=1.7) obliquely incident on a thick nickel plate in vacuum. The angular distributions of the summary radiation (i.e. the sums of radiations of various polarizations) both 'forward' and 'backward' for different azimuthal planes are presented in tables and diagrams for different particle inclination angles to the separation boundary. The examples of angular distributions of radiation having various polarizations (at the inclination angle of 45 0 ) show that they differ considerably. The spectra of summary radiation are of a monotonous character. The calculations have shown that in a relativistic case the forward radiation is concentrated near the direction of particle motion and backward radiation moves in an opposite direction with respect to that of the particle inclination. The dependence of the total yield of forward and backward transition radiations upon the particle inclination angle is approximately cos 2 psi. (Auth.)

  12. Cell response to quasi-monochromatic light with different coherence

    Energy Technology Data Exchange (ETDEWEB)

    Budagovsky, A V; Solovykh, N V [I.V.Michurin All-Russian Recearch Institute of Fruit Crops Genetics and Breeding (Russian Federation); Budagovskaya, O N [I.V.Michurin All-Russia Research and Development Institute of Gardening, Michurinsk, Tambov region (Russian Federation); Budagovsky, I A [P N Lebedev Physics Institute, Russian Academy of Sciences, Moscow (Russian Federation)

    2015-04-30

    The problem of the light coherence effect on the magnitude of the photoinduced cell response is discussed. The origins of ambiguous interpretation of the known experimental results are considered. Using the biological models, essentially differing in anatomy, morphology and biological functions (acrospires of radish, blackberry microsprouts cultivated in vitro, plum pollen), the effect of statistical properties of quasi-monochromatic light (λ{sub max} = 633 nm) on the magnitude of the photoinduced cell response is shown. It is found that for relatively low spatial coherence, the cell functional activity changes insignificantly. The maximal enhancement of growing processes (stimulating effect) is observed when the coherence length L{sub coh} and the correlation radius r{sub cor} are greater than the cell size, i.e., the entire cell fits into the field coherence volume. In this case, the representative indicators (germination of seeds and pollen, the spears length) exceeds those of non-irradiated objects by 1.7 – 3.9 times. For more correct assessment of the effect of light statistical properties on photocontrol processes, it is proposed to replace the qualitative description (coherent – incoherent) with the quantitative one, using the determination of spatial and temporal correlation functions and comparing them with the characteristic dimensions of the biological structures, e.g., the cell size. (biophotonics)

  13. Maximum dose angle for oblique incidence on primary beam protective barriers in the design of medical radiation therapy facilities

    International Nuclear Information System (INIS)

    Fondevila, Damian; Arbiser, Silvio; Sansogne, Rosana; Brunetto, Monica; Dosoretz, Bernardo

    2008-01-01

    Primary barrier determinations for the shielding of medical radiation therapy facilities are generally made assuming normal beam incidence on the barrier, since this is geometrically the most unfavorable condition for that shielding barrier whenever the occupation line is allowed to run along the barrier. However, when the occupation line (for example, the wall of an adjacent building) runs perpendicular to the barrier (especially roof barrier), then two opposing factors come in to play: increasing obliquity angle with respect to the barrier increases the attenuation, while the distance to the calculation point decreases, hence, increasing the dose. As a result, there exists an angle (α max ) for which the equivalent dose results in a maximum, constituting the most unfavorable geometric condition for that shielding barrier. Based on the usual NCRP Report No. 151 model, this article presents a simple formula for obtaining α max , which is a function of the thickness of the barrier (t E ) and the equilibrium tenth-value layer (TVL e ) of the shielding material for the nominal energy of the beam. It can be seen that α max increases for increasing TVL e (hence, beam energy) and decreases for increasing t E , with a range of variation that goes from 13 to 40 deg for concrete barriers thicknesses in the range of 50-300 cm and most commercially available teletherapy machines. This parameter has not been calculated in the existing literature for radiotherapy facilities design and has practical applications, as in calculating the required unoccupied roof shielding for the protection of a nearby building located in the plane of the primary beam rotation

  14. Application of Monochromatic Ocean Wave Forecasts to Prediction of Wave-Induced Currents

    Science.gov (United States)

    Poole, L. R.

    1975-01-01

    Stoke's wave-induced currents are compared, for variety of wind conditions resulting in partially developed seas and for two water depths, with currents induced by average and significant monochromatic waves related to Bretschneider spectrum.

  15. A monochromatic gravity wave observed by the Flatland Atmospheric Observatory

    Science.gov (United States)

    Vanzandt, T. E.; Chun, Hye-Yeong; Clark, W. L.; Einaudi, F.; Nastrom, G. D.; Riddle, A. C.; Warnock, J. M.

    1993-01-01

    On 21 December 1991 from approximately 1300 to approximately 1600 UTC a monochromatic wave train with an 8.2-min period was observed by the suite of instruments at the Flatland Atmospheric Observatory (FAO), located in very flat terrain near Champaign-Urbana, Illinois. A 915-MHz radar measured the vertical wind velocity w every 60 s from 0.55 km MSL (0.34 km AGL) to approximately 3 km with 250-m range gates, and a 50-MHz radar measured the oblique wind in four directions, as well as w, every 130 s from 2.75 to approximately 7.25 km with 750-m range gates. A meteorological ground station measured the surface pressure P, wind speed vector u and azimuth alpha, temperature, solar insolation, etc., every 30 s. P was also measured every 120 s by six digital barograph stations within 30 km of Flatland. Using the hodograph of surface vector u and alpha and the impedance relation, we estimated the azimuthal direction of propagation phi to be 45 deg +/- 15 deg clockwise from north, the intrinsic and apparent horizontal phase speeds C(sub i) and C(sub o), respectively, (which are about equal since the direction of propagation is about normal to the mean wind) to be 21 +/- 5 m/s, and the horizontal wavelength lambda to be 10.0 +/- 2.5 km. The peak-to-peak surface horizontal perturbation velocity varied from approximately 2 to 5 m/s from cycle to cycle.

  16. Radiation

    International Nuclear Information System (INIS)

    2013-01-01

    The chapter one presents the composition of matter and atomic theory; matter structure; transitions; origin of radiation; radioactivity; nuclear radiation; interactions in decay processes; radiation produced by the interaction of radiation with matter

  17. The measurement and analysis of normal incidence solar UVB radiation and its application to the photoclimatherapy protocol for psoriasis at the Dead Sea, Israel.

    Science.gov (United States)

    Kudish, Avraham I; Harari, Marco; Evseev, Efim G

    2011-01-01

    The broad-band normal incidence UVB beam radiation has been measured at Neve Zohar, Dead Sea basin, using a prototype tracking instrument composed of a Model 501A UV-Biometer mounted on an Eppley Solar Tracker Model St-1. The diffuse and beam fraction of the solar global UVB radiation have been determined using the concurrently measured solar global UVB radiation. The diffuse fraction was observed to exceed 80% throughout the year. The application of the results of these measurements to the possible revision of the photoclimatherapy protocol for psoriasis patients at the Dead Sea medical spas is now under investigation. The suggested revision would enable the sun-exposure treatment protocol to take advantage of the very high diffuse fraction by allowing the patient to receive the daily dose of UVB radiation without direct exposure to the sun, viz. receive the diffuse UVB radiation under a sunshade. This would require an increase in sun-exposure time intervals, as the UVB radiation intensity beneath a sunshade is less than that on an exposed surface. © 2010 The Authors. Photochemistry and Photobiology © 2010 The American Society of Photobiology.

  18. Increased incidence of myelodysplastic syndrome and acute myeloid leukemia following breast cancer treatment with radiation alone or combined with chemotherapy: a registry cohort analysis 1990-2005

    International Nuclear Information System (INIS)

    Kaplan, Henry G; Malmgren, Judith A; Atwood, Mary K

    2011-01-01

    Our objective was to measure myelodysplastic syndrome (MDS) and acute myelogenous leukemia (AML) risk associated with radiation and/or chemotherapy breast cancer (BC) treatment. Our study cohort was composed of BC patients diagnosed from 1990 to 2005 and followed up for blood disorders, mean length of follow up = 7.17 years, range 2-18 years. 5790 TNM stage 0-III patients treated with surgery alone, radiation and/or chemotherapy were included. Patients without surgery (n = 111), with stem cell transplantation (n = 98), unknown or non-standard chemotherapy regimens (n = 94), lost to follow up (n = 66) or 'cancer status unknown' (n = 67) were excluded. Rates observed at our community based cancer care institution were compared to SEER incidence data for rate ratio (RR) calculations. 17 cases of MDS/AML (10 MDS/7 AML) occurred during the follow up period, crude rate .29% (95% CI = .17, .47), SEER comparison RR = 3.94 (95% CI = 2.34, 6.15). The RR of MDS in patients age < 65 comparing our cohort incidence to SEER incidence data was 10.88 (95% CI = 3.84, 24.03) and the RR of AML in patients age < 65 was 5.32 (95% CI = 1.31, 14.04). No significant increased risk of MDS or AML was observed in women ≥ 65 or the surgery/chemotherapy-only group. A RR of 3.32 (95% CI = 1.42, 6.45) was observed in the surgery/radiation-only group and a RR of 6.32 (95% CI = 3.03, 11.45) in the surgery/radiation/chemotherapy group. 3 out of 10 MDS cases died of disease at an average 3.8 months post diagnosis and five of seven AML cases died at an average 9 months post diagnosis. An elevated rate of MDS and AML was observed among breast cancer patients < 65, those treated with radiation and those treated with radiation and chemotherapy compared to available population incidence data. Although a small number of patients are affected, leukemia risk associated with treatment and younger age is significant

  19. Perceived Incidence and Importance of Lay-Ideas on Ionizing Radiation: Results of a Delphi-Study among Radiation-Experts.

    Science.gov (United States)

    Eijkelhof, H. M. C.; And Others

    1990-01-01

    Described are lay-ideas which may exist about ionizing radiation, the importance of these ideas for risk management, and the relationships between various lay-ideas. Lay-ideas were used to gain a better insight into the problems of learning about ionizing radiation and to construct appropriate teaching materials and strategies. (KR)

  20. Updated estimates of the proportion of childhood leukaemia incidence in Great Britain that may be caused by natural background ionising radiation

    International Nuclear Information System (INIS)

    Little, Mark P; Wakeford, Richard; Kendall, Gerald M

    2009-01-01

    The aetiology of childhood leukaemia remains generally unknown, although exposure to moderate and high levels of ionising radiation, such as was experienced during the atomic bombings of Japan or from radiotherapy, is an established cause. Risk models based primarily upon studies of the Japanese A-bomb survivors imply that low-level exposure to ionising radiation, including to ubiquitous natural background radiation, also raises the risk of childhood leukaemia. In a recent paper (Wakeford et al 2009 Leukaemia 23 770-6) we estimated the proportion of childhood leukaemia incidence in Great Britain attributable to natural background radiation to be about 20%. In this paper we employ the two sets of published leukaemia risk models used previously, but use recently published revised estimates of natural background radiation doses received by the red bone marrow of British children to update the previous results. Using the newer dosimetry we calculate that the best estimate of the proportion of cases of childhood leukaemia in Great Britain predicted to be attributable to this source of exposure is 15-20%, although the uncertainty associated with certain stages in the calculation (e.g. the nature of the transfer of risk between populations and the pertinent dose received from naturally occurring alpha-particle-emitting radionuclides) is significant. The slightly lower attributable proportions compared with those previously derived by Wakeford et al (Leukaemia 2009 23 770-6) are largely due to the lower doses (and in particular lower high LET doses) for the first year of life.

  1. Radiation tolerance of the cervical spinal cord: incidence and dose-volume relationship of symptomatic and asymptomatic late effects following high dose irradiation of paraspinal tumors

    International Nuclear Information System (INIS)

    Liu, Mitchell C.C.; Munzenrider, John E.; Finkelstein, Dianne; Liebsch, Norbert; Adams, Judy; Hug, Eugen B.

    1997-01-01

    Purpose: Low grade chordomas and chondrosarcomas require high radiation doses for effective, lasting tumor control. Fractionated, 3-D planned, conformal proton radiation therapy has been used for lesions along the base of skull and spine to deliver high target doses, while respecting constraints of critical, normal tissues. In this study, we sought to determine the incidence of myelopathy after high dose radiotherapy to the cervical spine and investigated the influence of various treatment parameters, including dose-volume relationship. Methods and Materials: Between December 1980 and March 1996, 78 patients were treated at the Massachusetts General Hospital and Harvard Cyclotron Laboratory for primary or recurrent chordomas and chondrosarcomas of the cervical spine using combined proton and photon radiation therapy. In general, the tumor dose given was between 64.5 to 79.2 CGE (Cobalt Gray Equivalent). The guidelines for maximum permissible doses to spinal cord were: ≤ 64 CGE to the spinal cord surface and ≤ 53 CGE to the spinal cord center. Dose volume histograms of the spinal cord were analyzed to investigate a possible dose and volume relationship. Results: With a mean follow-up period of 46.6 months (range: 3 - 157 months), 4 of 78 patients (5.1%) developed high-grade (RTOG Grade 3 and 4) late toxicity: 3 patients (3.8%) experienced sensory deficits without motor deficits, none had any limitations of daily activities. One patient (1.2%) developed motor deficit with loss of motor function of one upper extremity. The only patient, who developed permanent motor damage had received additional prior radiation treatment and therefore received a cumulative spinal cord dose higher than the treatment guidelines. No patient treated within the guidelines experienced any motor impairment. Six patients (7.7%) experienced transient Lhermitt's syndrome and 1 patient (1.2%) developed asymptomatic radiographic MR findings only. Time to onset of symptoms of radiographic

  2. Incidence and mortality of solid cancer among emergency workers of the Chernobyl accident: assessment of radiation risks for the follow-up period of 1992-2009

    Energy Technology Data Exchange (ETDEWEB)

    Kashcheev, V.V.; Chekin, S.Yu.; Maksioutov, M.A.; Tumanov, K.A.; Kochergina, E.V.; Kashcheeva, P.V.; Shchukina, N.V.; Ivanov, V.K. [Russian Ministry of Health, Federal State Institution, Medical Radiological Research Center, Obninsk, Kaluga Region (Russian Federation)

    2015-03-15

    This paper presents the results of a retrospective cohort study of cancer incidence and mortality among emergency workers of the Chernobyl accident, for the follow-up period 1992-2009. The cohort selected for analysis consists of 67,568 emergency workers who worked in the Chernobyl exclusion zone in 1986-1987. External radiation whole-body absorbed dose varied from 0.0001 gray (Gy) to 1.24 Gy, with a median of 0.102 Gy. Over the follow-up period 1992-2009, a total of 4,002 solid cancers of different sites were identified as the result of annual compulsory health examination, and a total of 2,442 deaths from all solid cancers in the study cohort were reported. Poisson regression was applied for the analysis of cancer incidence and mortality. The analysis of the standardized incidence ratio (SIR) has shown a statistically significant increase in cancer incidence in the cohort as compared with baseline cancer incidence among males of Russia. The average excess over the entire follow-up period is 18 % [SIR = 1.18, 95 % confidence interval (CI) 1.15; 1.22]. In contrast, however, no increase in the mortality from all cancers among the emergency workers as compared to the baseline mortality in Russian men was found. Values of excess relative risk of cancer incidence and mortality per 1 Gy (ERR Gy{sup -1}) are 0.47 (95 % CI 0.03; 0.96, p value = 0.034) and 0.58 (95 % CI 0.002; 1.25, p value = 0.049), respectively. These values are statistically significant. (orig.)

  3. Biodosimetry: Medicine, Science, and Systems to Support the Medical Decision-Maker Following a Large Scale Nuclear or Radiation Incident

    International Nuclear Information System (INIS)

    Coleman, C. Norman; Koerner, John F.

    2016-01-01

    The public health and medical response to a radiological or nuclear incident requires the capability to sort, assess, treat, triage and to ultimately discharge, refer or transport people to their next step in medical care. The size of the incident and scarcity of resources at the location of each medical decision point will determine how patients are triaged and treated. This will be a rapidly evolving situation impacting medical responders at regional, national and international levels. As capabilities, diagnostics and medical countermeasures improve, a dynamic system-based approach is needed to plan for and manage the incident, and to adapt effectively in real time. In that the concepts and terms can be unfamiliar and possibly confusing, resources and a concept of operations must be considered well in advance. An essential underlying tenet is that medical evaluation and care will be managed by health-care professionals with biodosimetry assays providing critical supporting data. (authors)

  4. Estimation of incident solar radiation on the roof of the cultural and sports university centre of the Foundation University Los Libertadores

    International Nuclear Information System (INIS)

    Jiménez, S A; Carrillo, V M; Rátiva, L C

    2016-01-01

    This document shows the estimate of the total solar irradiance incident for the set of solar collectors to be located on the roof of cultural and sports university centre (CSUC) of the Foundation University Los Libertadores (FULL) in Bogotá, Colombia, and they will be part of the climate control system of the pool built inside. The calculation was based on experimental data of global solar radiation on the horizontal surface on March, July, October, November and December, through the three most commonly models used to determine the total solar radiation on tilted surfaces: isotropic sky, HDKR and Perez. The results show differences of less than 5% between the values calculated by the three models for December, the month with lower irradiance. For this month, reductions up to 15% and 19% were observed in the estimated irradiance, relative to those obtained on a horizontal surface on a surface under ideal orientation and inclination, respectively. (paper)

  5. Quenching of natural cyclotron instability by large amplitude monochromatic waves propagating in an inhomogeneous medium

    International Nuclear Information System (INIS)

    Cornilleau-Wehrlin, N.; Gendrin, R.

    1979-01-01

    Recent experiments have shown that a long duration monochromatic wave generated by a high power VLF transmitter may quench natural magnetospheric hiss emissions over a frequency range Δf of the order of 50-150 Hz below the transmitter frequency. The authors show that this effect can be interpreted by trapping, inside the monochromatic wave, of a certain amount of particles which were contributing to the generation of hiss in the equatorial region before the transmitter was switched on. The competition between the trapping and detrapping forces (the last one being due to the inhomogeneity of the medium) is studied. They show that the frequency range Δf which is concerned by this effect is proportional to b 2 , where b is the field intensity of the monochromatic wave. Δf is also an increasing function of the transmitter frequency. (Auth.)

  6. Cycles and transitivity by monochromatic paths in arc-coloured digraphs

    Directory of Open Access Journals (Sweden)

    Enrique Casas-Bautista

    2015-11-01

    The result by Sands et al. (1982 that asserts: Every 2-coloured digraph has a kernel by monochromatic paths, and the result by Galeana-Sánchez et al. (2011 that asserts: If D is a finite m-coloured digraph that admits a partition {C1,C2} of the set of colours of D such that for each i∈{1,2} every cycle in the subdigraph D[Ci] spanned by the arcs with colours in Ci is monochromatic, C(D does not contain neither rainbow triangles nor rainbow P3⃗ (path of length 3 involving colours of both C1 and C2; then D has a kernel by monochromatic paths.

  7. Two-color monochromatic x-ray imaging with a single short-pulse laser

    Science.gov (United States)

    Sawada, H.; Daykin, T.; McLean, H. S.; Chen, H.; Patel, P. K.; Ping, Y.; Pérez, F.

    2017-06-01

    Simultaneous monochromatic crystal imaging at 4.5 and 8.0 keV with x-rays produced by a single short-pulse laser is presented. A layered target consisting of thin foils of titanium and copper glued together is irradiated by the 50 TW Leopard short-pulse laser housed at the Nevada Terawatt Facility. Laser-accelerated MeV fast electrons transmitting through the target induce Kα fluorescence from both foils. Two energy-selective curved crystals in the imaging diagnostic form separate monochromatic images on a single imaging detector. The experiment demonstrates simultaneous two-color monochromatic imaging of the foils on a single detector as well as Kα x-ray production at two different photon energies with a single laser beam. Application of the diagnostic technique to x-ray radiography of a high density plasma is also presented.

  8. Decay of a weakly bound level in a monochromatic electromagnetic field and a static magnetic field

    International Nuclear Information System (INIS)

    Rylyuk, V.M.; Ortner, J.

    2003-01-01

    We consider an electron that is bound by a zero-range potential and a constant magnetic field and which becomes disturbed by a monochromatic laser beam with elliptical polarization. The exact solution of the Schroedinger equation for an electron in the presence of an arbitrary electromagnetic wave and a static magnetic field is obtained. Exact expressions have been found for the complex energy, whose real and imaginary parts yield the level position and the width of an electron in a zero-range force field, a constant magnetic field, and a monochromatic electromagnetic field. These expressions have been analyzed in details for the case of a circularly polarized laser light

  9. Mitotic effects of monochromatic ultraviolet radiation at 225, 265, and 280 nm on eleven stages of the cell cycle of the grasshopper neuroblast in culture. II. Changes in progression rate and cell sequence between the stage irradiated and nuclear membrane breakdown

    International Nuclear Information System (INIS)

    Carlson, J.G.

    1976-01-01

    Portions of embryos of the grasshopper, Chortophaga viridifasciata (DeGeer), were cultured in hanging drops under quartz cover slips. Immediately after exposure to 225, 265, or 280 nm radiation, microscope observations at 38 0 C were begun. The morphologically identified stage and the time after treatment of selected neuroblasts were recorded at short-time intervals until prometaphase was reached. Mitotic retardation induced by irradiation of prereplication stages (metaphase, anaphase, or early telophase) or S phase (middle or late telophase, interphase, or very early prophase) is greatest in postreplication stages (early, middle, and late prophase) and absent or minimal in stages morphologically identified as parts of S phase. Ultraviolet irradiation superimposes on the normal diversity of progression rates an additional variation factor, so that cells do not necessarily reach prometaphase in the order of their sequence at the time of treatment. This suggests the need for caution in ascribing particular radiosensitivities to substages of limited duration on the basis of the order in which they attain a subsequent stage

  10. Directional radiation detectors

    Science.gov (United States)

    Dowell, Jonathan L.

    2017-09-12

    Directional radiation detectors and systems, methods, and computer-readable media for using directional radiation detectors to locate a radiation source are provided herein. A directional radiation detector includes a radiation sensor. A radiation attenuator partially surrounds the radiation sensor and defines an aperture through which incident radiation is received by the radiation sensor. The aperture is positioned such that when incident radiation is received directly through the aperture and by the radiation sensor, a source of the incident radiation is located within a solid angle defined by the aperture. The radiation sensor senses at least one of alpha particles, beta particles, gamma particles, or neutrons.

  11. Monochromatic Minibeams Radiotherapy: From Healthy Tissue-Sparing Effect Studies Toward First Experimental Glioma Bearing Rats Therapy

    International Nuclear Information System (INIS)

    Deman, Pierre; Vautrin, Mathias; Edouard, Magali; Stupar, Vasile; Bobyk, Laure; Farion, Régine; Elleaume, Hélène; Rémy, Chantal; Barbier, Emmanuel L.; Estève, François; Adam, Jean-François

    2012-01-01

    Purpose: The purpose of this study was to evaluate high-dose single fraction delivered with monochromatic X-rays minibeams for the radiotherapy of primary brain tumors in rats. Methods and Materials: Two groups of healthy rats were irradiated with one anteroposterior minibeam incidence (four minibeams, 123 Gy prescribed dose at 1 cm depth in the brain) or two interleaved incidences (54 Gy prescribed dose in a 5 × 5 × 4.8 mm 3 volume centered in the right hemisphere), respectively. Magnetic resonance imaging (MRI) follow-up was performed over 1 year. T2-weighted (T2w) images, apparent diffusion coefficient (ADC), and blood vessel permeability maps were acquired. F98 tumor bearing rats were also irradiated with interleaved minibeams to achieve a homogeneous dose of 54 Gy delivered to an 8 × 8 × 7.8 mm 3 volume centered on the tumor. Anatomic and functional MRI follow-up was performed every 10 days after irradiation. T2w images, ADC, and perfusion maps were acquired. Results: All healthy rats were euthanized 1 year after irradiation without any clinical alteration visible by simple examination. T2w and ADC measurements remain stable for the single incidence irradiation group. Localized Gd-DOTA permeability, however, was observed 9 months after irradiation for the interleaved incidences group. The survival time of irradiated glioma bearing rats was significantly longer than that of untreated animals (49 ± 12.5 days versus 23.3 ± 2 days, p < 0.001). The tumoral cerebral blood flow and blood volume tend to decrease after irradiation. Conclusions: This study demonstrates the sparing effect of minibeams on healthy tissue. The increased life span achieved for irradiated glioma bearing rats was similar to the one obtained with other radiotherapy techniques. This experimental tumor therapy study shows the feasibility of using X-ray minibeams with high doses in brain tumor radiotherapy.

  12. Characterisation of corrosion deposits induced by carbon dioxide on mild steel using grazing incidence x-ray and synchrotron radiation diffraction

    International Nuclear Information System (INIS)

    Sembiring, S.; O'Connor, B; Li, D.; Buckley, C.; Van Riessen, A.; De Marco, R.

    1999-01-01

    Full text: Grazing incidence diffraction, using x-rays (GIXRD) and synchrotron radiation (GISRD), is being applied for near-surface characterisation of corrosion deposits formed on the internal surfaces of mild steel pipelines which are used to deliver natural gas from offshore deposits in Western Australia. These techniques are being employed to construct phase composition depth-profiles of corrosion product phases. The GIXRD data are being measured with CuKα radiation using a Siemens D5000 x-ray diffractometer, fitted with a primary beam slit system for incidence angle control and also with a diffracted beam monochromator; and the GISRD data have been acquired with the BIGDIFF instrument on the ANBF beamline in Tsukuba, Japan. The mild steel test samples are prepared with a laboratory reactor in which the corrosion conditions are simulated in a controlled manner. Results obtained to date have shown that two phases are readily observed in addition to the a-Fe phase from the mild steel substrate: (1) FeCO 3 (siderite) induced by CO 2 dissolved in the water flowing through the pipeline, and (2) CaCO 3 (calcite) deposited on the mild steel surface by reaction between the CO 2 and calcium ions which are also present in the water flowing through the pipeline. Supporting measurements from SEM imaging and associated EDS analysis will also be presented

  13. High-throughput estimation of incident light, light interception and radiation-use efficiency of thousands of plants in a phenotyping platform.

    Science.gov (United States)

    Cabrera-Bosquet, Llorenç; Fournier, Christian; Brichet, Nicolas; Welcker, Claude; Suard, Benoît; Tardieu, François

    2016-10-01

    Light interception and radiation-use efficiency (RUE) are essential components of plant performance. Their genetic dissections require novel high-throughput phenotyping methods. We have developed a suite of methods to evaluate the spatial distribution of incident light, as experienced by hundreds of plants in a glasshouse, by simulating sunbeam trajectories through glasshouse structures every day of the year; the amount of light intercepted by maize (Zea mays) plants via a functional-structural model using three-dimensional (3D) reconstructions of each plant placed in a virtual scene reproducing the canopy in the glasshouse; and RUE, as the ratio of plant biomass to intercepted light. The spatial variation of direct and diffuse incident light in the glasshouse (up to 24%) was correctly predicted at the single-plant scale. Light interception largely varied between maize lines that differed in leaf angles (nearly stable between experiments) and area (highly variable between experiments). Estimated RUEs varied between maize lines, but were similar in two experiments with contrasting incident light. They closely correlated with measured gas exchanges. The methods proposed here identified reproducible traits that might be used in further field studies, thereby opening up the way for large-scale genetic analyses of the components of plant performance. © 2016 INRA New Phytologist © 2016 New Phytologist Trust.

  14. The Use of Categorized Time-Trend Reporting of Radiation Oncology Incidents: A Proactive Analytical Approach to Improving Quality and Safety Over Time

    International Nuclear Information System (INIS)

    Arnold, Anthony; Delaney, Geoff P.; Cassapi, Lynette; Barton, Michael

    2010-01-01

    Purpose: Radiotherapy is a common treatment for cancer patients. Although incidence of error is low, errors can be severe or affect significant numbers of patients. In addition, errors will often not manifest until long periods after treatment. This study describes the development of an incident reporting tool that allows categorical analysis and time trend reporting, covering first 3 years of use. Methods and Materials: A radiotherapy-specific incident analysis system was established. Staff members were encouraged to report actual errors and near-miss events detected at prescription, simulation, planning, or treatment phases of radiotherapy delivery. Trend reporting was reviewed monthly. Results: Reports were analyzed for the first 3 years of operation (May 2004-2007). A total of 688 reports was received during the study period. The actual error rate was 0.2% per treatment episode. During the study period, the actual error rates reduced significantly from 1% per year to 0.3% per year (p < 0.001), as did the total event report rates (p < 0.0001). There were 3.5 times as many near misses reported compared with actual errors. Conclusions: This system has allowed real-time analysis of events within a radiation oncology department to a reduced error rate through focus on learning and prevention from the near-miss reports. Plans are underway to develop this reporting tool for Australia and New Zealand.

  15. Incidence of radiation-induced Graves' disease in patients treated with radioiodine for thyroid autonomy before and after introduction of a high-sensitivity TSH receptor antibody assay

    International Nuclear Information System (INIS)

    Dunkelmann, Simone; Wolf, Ricarda; Koch, Annedore; Kittner, Christian; Groth, Peter; Schuemichen, Carl

    2004-01-01

    Autoimmune hyperthyroidism may occur several months after radioiodine therapy (RIT) for functional thyroid autonomy. Exacerbation of pre-existing subclinical Graves' disease (GD) has been held responsible for this phenomenon. Determination of TSH receptor antibody using solubilised porcine epithelial cell membranes is insensitive and may have failed to diagnose GD in these patients before RIT. Following the introduction of a more sensitive assay, using the human TSH receptor as an antigen, it has been expected that the incidence of radiation-induced GD after RIT for functional thyroid autonomy will be reduced. In a first group of 1,428 patients treated between November 1993 and March 1997 (group I) we used the porcine TRAb assay to exclude GD, while in a second group comprising 1,408 patients treated between January 2000 and December 2001 (group II), GD was excluded using the human TRAb assay. A matched control group of 231 patients was derived from group II. In group I a total of 15 (1.05%) patients developed obvious or suspected radiation-induced GD, while in group II 17 (1.2%) did so; the interval until development of GD was 8.4 and 8.8 months, respectively, after RIT. Serum anti-thyroid peroxidase levels before RIT were elevated in 36.4% of group I patients and 47.1% of group II patients, but in only 5.6% of the control group. Other non-specific signs of mild immunopathy of the thyroid were seen retrospectively in 73.3%, 64.7% and 16.0% of the patients in these three groups, respectively. In conclusion, the introduction of a high-sensitivity TRAb assay did not reduce the incidence of autoimmune hyperthyroidism occurring late after RIT for functional thyroid autonomy, but mild immunopathy of the thyroid is seen more frequently in these patients and seems to be a predisposing factor in the development of radiation-induced GD. (orig.)

  16. Multiple scattering of polarized light: comparison of Maxwell theory and radiative transfer theory.

    Science.gov (United States)

    Voit, Florian; Hohmann, Ansgar; Schäfer, Jan; Kienle, Alwin

    2012-04-01

    For many research areas in biomedical optics, information about scattering of polarized light in turbid media is of increasing importance. Scattering simulations within this field are mainly performed on the basis of radiative transfer theory. In this study a polarization sensitive Monte Carlo solution of radiative transfer theory is compared to exact Maxwell solutions for all elements of the scattering Müller matrix. Different scatterer volume concentrations are modeled as a multitude of monodisperse nonabsorbing spheres randomly positioned in a cubic simulation volume which is irradiated with monochromatic incident light. For all Müller matrix elements effects due to dependent scattering and multiple scattering are analysed. The results are in overall good agreement between the two methods with deviations related to dependent scattering being prominent for high volume concentrations and high scattering angles.

  17. Blue cone monochromatism in a female due to skewed X-inactivation

    DEFF Research Database (Denmark)

    Frederiksen, Anja L; Duno, Morten; Welinder, Lotte Gjesing

    2014-01-01

    Blue cone monochromatism (BCM) is a rare cone dystrophy with recessive X-linked inheritance and therefore diagnosed in males whereas females are clinically unaffected. We present a female with clinically manifested BCM. The diagnosis was genetically verified with the identification of one single ...

  18. Effect of a combination of green and blue monochromatic light on broiler immune response.

    Science.gov (United States)

    Zhang, Ziqiang; Cao, Jing; Wang, Zixu; Dong, Yulan; Chen, Yaoxing

    2014-09-05

    Our previous study suggested that green light or blue light would enhance the broiler immune response; this study was conducted to evaluate whether a combination of green and blue monochromatic light would result in improved immune response. A total of 192 Arbor Acre male broilers were exposed to white light, red light, green light, and blue light from 0 to 26 days. From 27 to 49 days, half of the broilers in green light and blue light were switched to blue light (G-B) and green light (B-G), respectively. The levels of anti-Newcastle disease virus (NDV) and anti-bovine serum albumin (BSA) IgG in G-B group were elevated by 11.9-40.3% and 17.4-48.7%, respectively, compared to single monochromatic lights (Plight groups. However, the serum TNF-α concentration in the G-B group was reduced by 3.64-40.5% compared to other groups, and no significant difference was found between the G-B and B-G groups in any type of detection index at the end of the experiment. These results suggested that the combination of G-B and B-G monochromatic light could effectively enhance the antibody titer, the proliferation index of lymphocytes and alleviate the stress response in broilers. Therefore, the combination of green and blue monochromatic light can improve the immune function of broilers. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. A Photodegradation Study of Three Common Paint and Plaster Biocides under monochromatic UV Light

    DEFF Research Database (Denmark)

    Minelgaite, Greta; Vollertsen, Jes; Nielsen, Asbjørn Haaning

    2014-01-01

    Photodegradation of the three common paint-and-plaster biocides (carbendazim, diuron and terbutryn) was investigated at controlled laboratory conditions. Samples prepared in two types of water (demineralized water and pond water) were subjected to 254 nm monochromatic UV light. Light intensity (W m...

  20. Nonlinear behavior of a monochromatic wave in a one-dimensional Vlasov plasma

    International Nuclear Information System (INIS)

    Shoucri, M.M.; Gagne, R.R.J.

    1978-01-01

    The nonlinear evolution of a monochromatic wave in a one-dimensional Vlasov plasma is studied numerically. The numerical results are carried out far enough in time for phase mixing to dominate the asymptotic state of the system. A qualitative comparison with previously reported simulations is given

  1. Pustular Palmoplantar Psoriasis Successfully Treated with Nb-UVB Monochromatic Excimer Light: A Case-Report

    Directory of Open Access Journals (Sweden)

    Serena Gianfaldoni

    2017-07-01

    Full Text Available Barber’s palmoplantar pustulosis (PPP is a form of localised pustular psoriasis, affecting the palmar and plantar surfaces. It is a chronic disease, with a deep impact on the patients’ quality of life. The Authors discuss a case of Baber Psoriasis successfully treated with monochromatic excimer light.

  2. The effects of low-level ionizing radiation and copper exposure on the incidence of antibiotic resistance in lentic biofilm bacteria.

    Science.gov (United States)

    McArthur, J Vaun; Dicks, Christian A; Bryan, A Lawrence; Tuckfield, R Cary

    2017-09-01

    Environmental reservoirs of antibiotic resistant bacteria are poorly understood. Understanding how the environment selects for resistance traits in the absence of antibiotics is critical in developing strategies to mitigate this growing menace. Indirect or co-selection of resistance by environmental pollution has been shown to increase antibiotic resistance. However no attention has been given to the effects of low-level ionizing radiation or the interactions between radiation and heavy metals on the maintenance or selection for antibiotic resistance (AR) traits. Here we explore the effect of radiation and copper on antibiotic resistance. Bacteria were collected from biofilms in two ponds - one impacted by low-level radiocesium and the other an abandoned farm pond. Through laboratory controlled experiments we examined the effects of increasing concentrations of copper on the incidence of antibiotic resistance. Differences were detected in the resistance profiles of the controls from each pond. Low levels (0.01 mM) of copper sulfate increased resistance but 0.5 mM concentrations of copper sulfate depressed the AR response in both ponds. A similar pattern was observed for levels of multiple antibiotic resistance per isolate. The first principal component response of isolate exposure to multiple antibiotics showed significant differences among the six isolate treatment combinations. These differences were clearly visualized through a discriminant function analysis, which showed distinct antibiotic resistance response patterns based on the six treatment groups. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Intermanufacturer Comparison of Dual-Energy CT Iodine Quantification and Monochromatic Attenuation: A Phantom Study.

    Science.gov (United States)

    Jacobsen, Megan C; Schellingerhout, Dawid; Wood, Cayla A; Tamm, Eric P; Godoy, Myrna C; Sun, Jia; Cody, Dianna D

    2018-04-01

    Purpose To determine the accuracy of dual-energy computed tomographic (CT) quantitation in a phantom system comparing fast kilovolt peak-switching, dual-source, split-filter, sequential-scanning, and dual-layer detector systems. Materials and Methods A large elliptical phantom containing iodine (2, 5, and 15 mg/mL), simulated contrast material-enhanced blood, and soft-tissue inserts with known elemental compositions was scanned three to five times with seven dual-energy CT systems and a total of 10 kilovolt peak settings. Monochromatic images (50, 70, and 140 keV) and iodine concentration images were created. Mean iodine concentration and monochromatic attenuation for each insert and reconstruction energy level were recorded. Measurement bias was assessed by using the sum of the mean signed errors measured across relevant inserts for each monochromatic energy level and iodine concentration. Iodine and monochromatic errors were assessed by using the root sum of the squared error of all measurements. Results At least one acquisition paradigm per scanner had iodine biases (range, -2.6 to 1.5 mg/mL) with significant differences from zero. There were no significant differences in iodine error (range, 0.44-1.70 mg/mL) among the top five acquisition paradigms (one fast kilovolt peak switching, three dual source, and one sequential scanning). Monochromatic bias was smallest for 70 keV (-12.7 to 15.8 HU) and largest for 50 keV (-80.6 to 35.2 HU). There were no significant differences in monochromatic error (range, 11.4-52.0 HU) among the top three acquisition paradigms (one dual source and two fast kilovolt peak switching). The lowest accuracy for both measures was with a split-filter system. Conclusion Iodine and monochromatic accuracy varies among systems, but dual-source and fast kilovolt-switching generally provided the most accurate results in a large phantom. © RSNA, 2017 Online supplemental material is available for this article.

  4. Wave-flume experiments of soft-rock cliff erosion under monochromatic waves

    Science.gov (United States)

    Regard, Vincent; Astruc, Dominique; Caplain, Bastien

    2017-04-01

    We investigate how cliffs erode under wave attack. Rocky coast erosion works through cycles, each one corresponding to three successive phases: (i) notch creation at cliff toe by mechanical action of waves, (ii) cliff fracturation leading to collapse, and (iii) evacuation of scree aprons by waves and currents. We performed experiments in a 5m x 14cm x 25cm wave flume (15 cm water depth) to investigate how waves are eroding a rocky coast. The cliff is made of wet sand and models a relatively soft rock. We used 3 different grain size (D50 = 0.28-0.41-0.48 mm), changing the cliff rheology. Waves are monochromatic; their height and period differ for the various experiments. Actual wave parameters are estimated by capacitive probes located offshore. The experiments are monitored by two video cameras both on the side and above the flume. Pictures are taken at a rate of 1Hz during the first 4h and then the rate is decreased to 0.1Hz till the end of experiment (about 1 day). The monitoring ensure a confident characterization of experiments in terms of waves (surf similarity parameter ξ and the incident wave energy flux F) and in terms of sediment (Dean number Ω and Shields number θb at breakers). Experiments begin by an initial phase of quick cliff retreat. Then the system evolves with slower cliff retreat. We focus on bottom morphology which we characterize in function of wave forcing (ξ, F). We show that the bottom morphology mainly depends on ξ. For our reference sediment (Dm = 0.41 mm), we observed: (i) surging breakers on a steep terrace (type T1) for ξ > 0.65; (ii)collapsing breakers on a bared profile attached to the inner platform (type T2) for 0.55< ξ <0.6; (iii) spilling breakers on gentle terrace (type T3) for F < 1.3 W/m and 0.55< ξ <0.6. Another bottom morphology, type T4, displays two sub-systems, an outer system with a double-bar profile where breaking waves are plunging, and an inner system with a T1, T2 or T3 profile. Some of these bottom

  5. Incidence of thyroid cancer in women in relation to previous exposure to radiation therapy and history of thyroid disease

    International Nuclear Information System (INIS)

    McTiernan, A.M.; Weiss, N.S.; Daling, J.R.

    1984-01-01

    Female residents of 13 counties of Western Washington, in whom papillary, follicular, or mixed papillary-follicular thyroid carcinomas had been diagnosed between 1974 and 1979 were interviewed regarding their medical and reproductive histories and past exposure to radiation treatments. For comparison, a random sample of women from the same population was interviewed. Women who had received radiation treatments to the head or neck prior to 5 years before interview were 16.5 times (95% confidence interval . 8.1-33.5) more likely than unexposed women to develop cancer. The relative risk (RR) was highest for papillary cancer (19.4) but also was elevated substantially for follicular and mixed papillary-follicular tumors. Women first irradiated at age 19 years or younger had a much higher RR than did women irradiated at age 20 or older. Regardless of prior radiation exposure, women who ever had had a goiter were at increased risk of developing thyroid cancer. Women who had ever developed a goiter had 17 times the risk of developing follicular cancer and almost 7 times the risk of developing papillary cancer as compared with women who never had had a goiter. Risk of thyroid cancer was elevated even among women who had had a history of goiter many years prior to diagnosis. A history of thyroid nodules was also a risk factor for papillary and mixed thyroid cancer. Neither a history of hypothyroidism nor hyperthyroidism was found to increase the risk of thyroid cancer

  6. 2011 Japanese Nuclear Incident

    Science.gov (United States)

    EPA’s RadNet system monitored the environmental radiation levels in the United States and parts of the Pacific following the Japanese Nuclear Incident. Learn about EPA’s response and view historical laboratory data and news releases.

  7. Assessment of radiation doses due to normal operation, incidents and accidents of the final disposal facility; Kaeytetyn ydinpolttoaineen loppusijoituslaitoksen normaalikaeytoen, kaeyttoehaeirioeiden ja onnettomuustilanteiden aiheuttamien saeteilyannosten arviointi

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, J.; Raiko, H.; Suolanen, V.; Ilvonen, M. [VTT Energy, Espoo (Finland)

    1999-03-01

    Radiation doses for workers of the encapsulation and disposal facility and for inhabitants in the environment caused by the facility during its operation were considered. The study covers both the normal operation of the plant and some hypothetical incidents and accidents. Occupational radiation doses inside the plant during normal operation are based on the design basis, assuming that highest permitted dose levels are prevailing in control rooms during fuel transfer and encapsulation processes. Release through the ventilation stack is assumed to be filtered both in normal operation and in hypothetical incident and accident cases. Calculation of the offsite doses from normal operation is based on the hypothesis that one fuel pin per 100 fuel bundles for all batches of spent fuel transported to the encapsulation facility is leaking. The release magnitude in incidents and accidents is based on the event chains, which lead to loss of fuel pin tightness followed by a discharge of radionuclides into the handling chamber and to some degree through the ventilation stack into atmosphere. The weather data measured at the Olkiluoto meteorological mast was employed for calculating of offsite doses. Therefore doses could be calculated in a large amount of different dispersion conditions, the statistical frequencies of which have, been measured. Finally doses were combined into cumulative distributions, from which a dose value representing the 99.5 % confidence level, is presented. The dose values represent the exposure of a critical group, which is assumed to live at the distance of 200 meters from the encapsulation and disposal plant and thus it will receive the largest doses in most dispersion conditions. Exposure pathways considered were: cloudsnine, inhalation, groundshine and nutrition (milk of cow, meat of cow, green vegetables, grain and root vegetables). Nordic seasonal variation is included in ingestion dose models. The results obtained indicate that offsite doses

  8. Evaluation of moving-coil loudspeaker and passive radiator parameters using normal-incidence sound transmission measurements: theoretical developments.

    Science.gov (United States)

    Leishman, Timothy W; Anderson, Brian E

    2013-07-01

    The parameters of moving-coil loudspeaker drivers are typically determined using direct electrical excitation and measurement. However, as electro-mechano-acoustical devices, their parameters should also follow from suitable mechanical or acoustical evaluations. This paper presents the theory of an acoustical method of excitation and measurement using normal-incidence sound transmission through a baffled driver as a plane-wave tube partition. Analogous circuits enable key parameters to be extracted from measurement results in terms of open and closed-circuit driver conditions. Associated tools are presented that facilitate adjacent field decompositions and derivations of sound transmission coefficients (in terms of driver parameters) directly from the circuits. The paper also clarifies the impact of nonanechoic receiving tube terminations and the specific benefits of downstream field decompositions.

  9. WE-G-BRA-03: Developing a Culture of Patient Safety Utilizing the National Radiation Oncology Incident Learning System (ROILS)

    Energy Technology Data Exchange (ETDEWEB)

    Hasson, B; Workie, D; Geraghty, C [Anne Arundel Medical Center, Annapolis, MD (United States)

    2015-06-15

    Purpose: To transition from an in-house incident reporting system to a ROILS standards system with the intent to develop a safety focused culture in the Department and enroll in ROILS. Methods: Since the AAPM Safety Summit (2010) several safety and reporting systems have been implemented within the Department. Specific checklists and SBAR reporting systems were introduced. However, the active learning component was lost due to reporting being viewed with distrust and possible retribution.To Facilitate introducing ROILS each leader in the Department received a copy of the ROILS participation guide. Four specific tasks were assigned to each leader: develop a reporting tree, begin the ROILS based system, facilitate adopting ROILS Terminology, and educate the staff on expectations of safety culture. Next, the ROILS questions were broken down into area specific questions (10–15) per departmental area. Excel spreadsheets were developed for each area and setup for error reporting entries. The Role of the Process Improvement Committee (PI) has been modified to review and make recommendations based on the ROILS entries. Results: The ROILS based Reporting has been in place for 4 months. To date 64 reports have been entered. Since the adoption of ROILS the reporting of incidents has increased from 2/month to 18/month on average. Three reports had a dosimetric effect on the patient (<5%) dose variance. The large majority of entries have been Characterized as Processes not followed or not sure how to Characterize, and Human Behavior. Conclusion: The majority of errors are typo’s that create confusion. The introduction of the ROILS standards has provided a platform for making changes to policies that increase patient safety. The goal is to develop a culture that sees reporting at a national level as a safe and effective way to improve our safety, and to dynamically learn from other institutions reporting.

  10. Gamma-H2AX biodosimetry for use in large scale radiation incidents: comparison of a rapid ‘96 well lyse/fix’ protocol with a routine method

    Directory of Open Access Journals (Sweden)

    Jayne Moquet

    2014-03-01

    Full Text Available Following a radiation incident, preliminary dose estimates made by γ-H2AX foci analysis can supplement the early triage of casualties based on clinical symptoms. Sample processing time is important when many individuals need to be rapidly assessed. A protocol was therefore developed for high sample throughput that requires less than 0.1 ml blood, thus potentially enabling finger prick sampling. The technique combines red blood cell lysis and leukocyte fixation in one step on a 96 well plate, in contrast to the routine protocol, where lymphocytes in larger blood volumes are typically separated by Ficoll density gradient centrifugation with subsequent washing and fixation steps. The rapid ‘96 well lyse/fix’ method reduced the estimated sample processing time for 96 samples to about 4 h compared to 15 h using the routine protocol. However, scoring 20 cells in 96 samples prepared by the rapid protocol took longer than for the routine method (3.1 versus 1.5 h at zero dose; 7.0 versus 6.1 h for irradiated samples. Similar foci yields were scored for both protocols and consistent dose estimates were obtained for samples exposed to 0, 0.2, 0.6, 1.1, 1.2, 2.1 and 4.3 Gy of 250 kVp X-rays at 0.5 Gy/min and incubated for 2 h. Linear regression coefficients were 0.87 ± 0.06 (R2 = 97.6% and 0.85 ± 0.05 (R2 = 98.3% for estimated versus actual doses for the routine and lyse/fix method, respectively. The lyse/fix protocol can therefore facilitate high throughput processing for γ-H2AX biodosimetry for use in large scale radiation incidents, at the cost of somewhat longer foci scoring times.

  11. Mapping the Ionization State of Laser-Irradiated Ar Gas Jets With Multi-Wavelength Monochromatic X-Ray Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kugland, N L; Doppner, T; Kemp, A; Schaeffer, D; Glenzer, S H; Niemann, C

    2010-04-08

    Two-dimensional monochromatic images of fast-electron stimulated Ar K{alpha} and He-{alpha} x-ray self-emission have recorded a time-integrated map of the extent of Ar{sup {approx}6+} and Ar{sup 16+} ions, respectively, within a high density (10{sup 20} cm{sup -3} atomic density) Ar plasma. This plasma was produced by irradiating a 2 mm wide clustering Ar gas jet with an ultra-high intensity (10{sup 19} W/cm{sup 2}, 200 fs) Ti:Sapphire laser operating at 800 nm. Spherically bent quartz crystals in the 200 (for K{alpha}) and 201 (for He-{alpha}) planes were used as near-normal incidence reflective x-ray optics. We see that a large (830 {micro}m long) region of plasma emits K{alpha} primarily along the laser axis, while the He-{alpha} emission is confined to smaller hot spot (230 {micro}m long) region that likely corresponds to the focal volume of the f/8 laser beam. X-ray spectra from a Bragg spectrometer operating in the von Hamos geometry, which images in one dimension, indicate that the centroids of the K{alpha} and He-{alpha} emission regions are separated by approximately 330 {micro}m along the laser axis.

  12. Mapping the ionization state of laser-irradiated Ar gas jets with multiwavelength monochromatic x-ray imaging.

    Science.gov (United States)

    Kugland, N L; Döppner, T; Kemp, A; Schaeffer, D; Glenzer, S H; Niemann, C

    2010-10-01

    Two-dimensional monochromatic images of fast-electron stimulated Ar Kα and He-α x-ray self-emission have recorded a time-integrated map of the extent of Ar(≈6+) and Ar(16+) ions, respectively, within a high density (10(20) cm(-3) atomic density) Ar plasma. This plasma was produced by irradiating a 2 mm wide clustering Ar gas jet with an ultrahigh intensity (10(19) W/cm(2), 50 TW) Ti:sapphire laser operating at 800 nm. Spherically bent quartz crystals in the 200 (for Kα) and 201 (for He-α) planes were used as near-normal incidence reflective x-ray optics. We see that a large (830 μm long) region of plasma emits Kα primarily along the laser axis, while the He-α emission is confined to smaller hot spot (230 μm long) region that likely corresponds to the focal volume of the f/8 laser beam. X-ray spectra from a Bragg spectrometer operating in the von Hamos geometry indicate that the centroids of the Kα and He-α emission regions are separated by approximately 330 μm along the laser axis.

  13. Progress towards monochromatic imaging of mix at the NIF

    Science.gov (United States)

    Kyrala, G. A.; Murphy, T. J.; Bradley, P. A.; Krashenninnikova, N. S.; Tregillis, I. L.; Obrey, K.; Shah, R. C.; Hakel, P.; Kline, J. L.; Grim, G. P.; Schmitt, M. J.; Kanzleiter, R. J.; Regan, S. P.; Barrios, M. A.

    2013-10-01

    Mix of non-hydrogenic (Z >1) material into the hydrogenic (D and T) ICF capsule fuel degrades implosion performance. The amount of degradation depends on the degree and the spatial distribution of mix. Experiments are underway at NIF to quantify the mix of shell material into fuel using directly driven capsules. CH or CD shells with various dopants, implanted at different depths in the shell are being used to change the amount of dopant mix. Spatially and spectrally resolved emission from the ionized dopants will be used to generate spatially and temporally dependent density and temperature maps of the ionized dopants that are mixed and heated in the core plasma. This information will be used to validate different mix models. This talk will describe the search for the appropriate dopant that gave a radiation spectrum that could be used to record images with the MMI diagnostic. This work is supported by US DOE/NNSA, performed at LANL, operated by LANS LLC under contract DE-AC52-06NA25396.

  14. Population exposure to ultraviolet radiation in Finland 1920-1995: Exposure trends and a time-series analysis of exposure and cutaneous melanoma incidence

    International Nuclear Information System (INIS)

    Kojo, Katja; Jansen, Christer T.; Nybom, Pia; Huurto, Laura; Laihia, Jarmo; Ilus, Taina; Auvinen, Anssi

    2006-01-01

    Ultraviolet radiation (UVR) is the principal cause of cutaneous malignant melanoma (CMM). However, the relation between CMM and UVR exposure is not clear. We present the trends of population exposure to UVR and conduct a time-series analysis of the relation between UVR exposure and incidence of CMM. Data on CMM incidence were obtained from the Finnish Cancer Registry. Clothing coverage of the body was scored from archival photographs and the proportion of uncovered skin was used as a measure of solar exposure. Information on the number of sunny resort holidays, duration of annual holidays, and sunscreen sales were obtained from various sources. Exposed skin area doubled from 1920 to 1985. The average duration of annual holidays increased 30-fold. The number of sunny resort holidays and the sales of sunscreens increased rapidly from 1980. CMM was most strongly associated with solar exposure of 5-19 years earlier. There is a considerable decrease in clothing coverage during the 20th century. UVR exposure preceding CMM occurrence 4 years or less does not appear relevant, whereas the period 5-19 years prior to CMM occurrence might be the most relevant period. However, findings of ecological studies may not be applicable at the individual level

  15. Application Research of Quasi-monochromatic X-ray Machine Replacing 241Am Radioactive Source in Thickness Measurement

    Directory of Open Access Journals (Sweden)

    LIN Hui1;XIAO Xue-fu2;HOU Yue-xin3;ZHAO Jing1;JIAN Li-min1

    2014-02-01

    Full Text Available In the research of BS-03 thickness detector, a self-designed quasi-monochromatic (50-60 keV X-ray machine was studied as a substitution to Am-241 low energy photon source(1.11×109 Bq)The range of output current, the attenuation of X rays through the steel plate, the aluminum plate, and the organic glass plate and stability of quasi-monochromatic X-ray machine was tested. The result showed that quasi-monochromatic X-ray machine could be an applicable replacement of Am-241 radioactive source.

  16. Radiation emission and its influence on the motion of multi-GeV electrons and positrons incident on a single diamond crystal

    CERN Document Server

    Kirsebom, K; Uggerhøj, Erik; Elsener, K; Ballestrero, S; Sona, P; Connell, S H; Sellschop, J P Friedel; Vilakazi, Z Z

    2001-01-01

    A few years ago the CERN NA-43 collaboration installed an upgraded detector system which allows a detailed analysis of the particle motion before, during and after penetration of a crystal. Also, essentially perfect diamond crystals were produced by the collaborators from Schonland Research Centre. These facts have led to new and very detailed investigations of QED-processes in strong crystalline fields. Along axial directions the radiation emission is enhanced by more than two orders of magnitude. For incidence on a 0.7 mm thick diamond crystal of well-aligned 149 GeV electrons, 35% give rise to a high energy photon peak at approximately=120 GeV. For 243 GeV electrons and approximately=200 GeV photons, this number decreases to 25%-which may be an indication of quantum suppression. Different measurements of the photon multiplicities show that in most cases positrons and electrons emit equal number of photons. The dramatic radiation emission leads to a strong reduction in transverse energy and all electrons in...

  17. Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

    International Nuclear Information System (INIS)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Mueller, P.; Ulm, G.

    2009-01-01

    Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation.

  18. Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

    Science.gov (United States)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Müller, P.; Ulm, G.

    2009-09-01

    Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation.

  19. Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, M. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Krumrey, M. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)], E-mail: Michael.Krumrey@ptb.de; Cibik, L.; Mueller, P.; Ulm, G. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)

    2009-09-11

    Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation.

  20. Monochromatization of femtosecond XUV light pulses with the use of reflection zone plates.

    Science.gov (United States)

    Metje, Jan; Borgwardt, Mario; Moguilevski, Alexandre; Kothe, Alexander; Engel, Nicholas; Wilke, Martin; Al-Obaidi, Ruba; Tolksdorf, Daniel; Firsov, Alexander; Brzhezinskaya, Maria; Erko, Alexei; Kiyan, Igor Yu; Aziz, Emad F

    2014-05-05

    We report on a newly built laser-based tabletop setup which enables generation of femtosecond light pulses in the XUV range employing the process of high-order harmonic generation (HHG) in a gas medium. The spatial, spectral, and temporal characteristics of the XUV beam are presented. Monochromatization of XUV light with minimum temporal pulse distortion is the central issue of this work. Off-center reflection zone plates are shown to be advantageous when selection of a desired harmonic is carried out with the use of a single optical element. A cross correlation technique was applied to characterize the performance of the zone plates in the time domain. By using laser pulses of 25 fs length to pump the HHG process, a pulse duration of 45 fs for monochromatized harmonics was achieved in the present setup.

  1. Electromagnetically Induced Transparency and Absorption of A Monochromatic Light Controlled by a Radio Frequency Field

    International Nuclear Information System (INIS)

    Cai Xun-Ming

    2015-01-01

    Electromagnetically induced transparency and absorption of a monochromatic light controlled by a radio frequency field in the cold multi-Zeeman-sublevel atoms are theoretically investigated. These Zeeman sublevels are coupled by a radio frequency (RF) field. Both electromagnetically induced transparency and electromagnetically induced absorption can be obtained by tuning the frequency of RF field for both the linear polarization and elliptical polarization monochromatic lights. When the transfer of coherence via spontaneous emission from the excited state to the ground state is considered, electromagnetically induced absorption can be changed into electromagnetically induced transparency with the change of intensity of radio field. The transparency windows controlled by the RF field can have potential applications in the magnetic-field measurement and quantum information processing. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  2. Studying the effect of spectral variations intensity of the incident solar radiation on the Si solar cells performance

    Directory of Open Access Journals (Sweden)

    Ahmed Elsayed Ghitas

    2012-12-01

    Full Text Available Solar spectral variation is important in characterization of photovoltaic devices. We present results of an experimental investigation of the effects of the daily spectral variation on the device performance of multicrystalline silicon photovoltaic module. The investigation concentrate on the analysis of outdoor solar spectral measurements carried out at 1 min intervals on clear sky days. Short circuit current and open circuit voltage have been measured to describe the module electrical performance. We have shown that the shift in the solar spectrum towards infrared has a negative impact on the device performance of the module. The spectral bands in the visible region contribute more to the short circuit current than the bands in the infrared region while the ultraviolet region contributes least. The quantitative effect of the spectral variation on the performance of the photovoltaic module is reflected on their respective device performance parameters. The decrease in the visible and the increase in infrared of the radiation spectra account for the decreased current collection and hence power of the module.

  3. Evaluating MTCLIM for incident daily solar radiation and humidity in diverse meteorological and topographical environments in the main Hawaiian Islands

    Science.gov (United States)

    Giambelluca, T. W.; Needham, H.; Longman, R. J.

    2017-12-01

    Continuous and high resolution climatologies are important inputs in determining future scenarios for land processes. In Hawaíi, a lack of continuous meteorological data has been a problem for both ecological and hydrological research of land-surface processes at daily time scales. For downward shortwave radiation (SWdown) and relative humidity (RH) climate variables, the number of surface stations which record daily values are limited and tend to be situated at city airports or in convenient locations leaving large sections of the islands underrepresented. The aim of this study is to evaluate the rationale behind using the mountain microclimate simulator MTCLIM to obtain a gridded observation based ensemble of SWdown and RH data at a daily increment for the period of 1990-2014 for the main Hawaiian Islands. Preliminary results, testing model output with observed data, show mean bias errors (%MBE) of 1.15 W/m2 for SWdown and -0.8% for RH. Mean absolute errors (%MAE) of 32.83 W/m2 SWdown and 14.96% RH, with root mean square errors (%RMSE) of 40.17 W/m2 SWdown and 11.75% RH. Further optimization of the model and additional methods to reduce errors are being investigated to improve the model's functionality with Hawaíi's extreme climate gradients.

  4. Near monochromatic X-rays for digital slot-scan mammography: initial findings

    International Nuclear Information System (INIS)

    Diekmann, Felix; Diekmann, S.; Richter, K.; Bick, U.; Fischer, T.; Hamm, B.; Lawaczeck, R.; Press, W.R.; Schoen, K.; Weinmann, H.J.; Arkadiev, V.; Bjeoumikhov, A.; Langhoff, N.; Rabe, J.; Roth, P.; Tilgner, J.; Wedell, R.; Krumrey, M.; Linke, U.; Ulm, G.

    2004-01-01

    X-ray spectra are composed of a broad bremsspectrum and anode-characteristic emission lines. In mammography typically molybdenum (Mo), rhodium (Rh) or tungsten (W) anodes are used in combination with Mo, Rh or aluminium filters. Only the photons with energies between 17 and 22 keV of the resulting spectrum are suitable for the soft tissue imaging needed for mammography. The aim of this article is to present first results obtained with a monochromator module mounted at the exit of the X-ray tube of a conventional clinical mammography unit. The experimental setup consists of a Siemens Mammomat 300, an X-ray monochromator module and a linear array detector for image acquisition. The technique is similar to the slot-scan technique known from digital mammography. The experimental machine allows to obtain images both with polychromatic and monochromatic X-rays. Initial evaluation of the system was performed by examination of a contrast-detail phantom (CD-MAM-phantom, Nijmegen, The Netherlands). Images done with the new monochromatic technique were compared to images of the phantom done with polychromatic spectra, with film-screen mammography as well as with digital mammography. The new technique with monochromatic slot-scan mammography resulted in correct identification of 93% of the phantom. Digital slot-scan mammography with polychromatic beam resulted in correct identification of 87%, digital full-field mammography in 83% and conventional film-screen mammography in 70% of the phantom. The results suggest that monochromatization has a potential for improving image quality or decreasing dose in X-ray mammography. (orig.)

  5. Melatonin modulates monochromatic light-induced GHRH expression in the hypothalamus and GH secretion in chicks.

    Science.gov (United States)

    Zhang, Liwei; Cao, Jing; Wang, Zixu; Dong, Yulan; Chen, Yaoxing

    2016-04-01

    To study the mechanism by which monochromatic lights affect the growth of broilers, a total of 192 newly hatched broilers, including the intact, sham-operated and pinealectomy groups, were exposed to white light (WL), red light (RL), green light (GL) and blue light (BL) using a light-emitting diode (LED) system for 2 weeks. The results showed that the GHRH-ir neurons were distributed in the infundibular nucleus (IN) of the chick hypothalamus. The mRNA and protein levels of GHRH in the hypothalamus and the plasma GH concentrations in the chicks exposed to GL were increased by 6.83-31.36%, 8.71-34.52% and 6.76-9.19% compared to those in the chicks exposed to WL (P=0.022-0.001), RL (P=0.002-0.000) and BL (P=0.290-0.017) in the intact group, respectively. The plasma melatonin concentrations showed a positive correlation with the expression of GHRH (r=0.960) and the plasma GH concentrations (r=0.993) after the various monochromatic light treatments. After pinealectomy, however, these parameters decreased and there were no significant differences between GL and the other monochromatic light treatments. These findings suggest that melatonin plays a critical role in GL illumination-enhanced GHRH expression in the hypothalamus and plasma GH concentrations in young broilers. Copyright © 2016 Elsevier GmbH. All rights reserved.

  6. Antibacterial and Antifungal Effect of 405 nm Monochromatic Laser on Endodontopathogenic Microorganisms

    Directory of Open Access Journals (Sweden)

    Takahiro Imamura

    2014-01-01

    Full Text Available The purpose of this study is to evaluate the usefulness of 405 nm monochromatic laser irradiation as an alternative management for prevention and/or treatment of endodontic infections. A monochromatic laser-emitting device equipped with a 405-nm laser diode was developed. Using this device, the effect of 405 nm laser irradiation on the growth of Porphyromonas gingivalis, Prevotella intermedia, Enterococcus faecalis, and Candida albicans, which are microorganisms associated with persistent endodontic infections, was evaluated by viable colony counting. As a result, the irradiation with a 405 nm laser had a significant bactericidal/fungicidal effect on P. gingivalis, P. intermedia, and C. albicans, whereas the growth of E. faecalis was not affected by the irradiation. The inhibition rate in P. gingivalis and P. intermedia was ~60% and ~80%, respectively, following irradiation at 0.2 W for 300 sec. The inhibition rate in C. albicans was ~90% following irradiation at 0.2 W for 1200 sec. These results indicate that 405 nm monochromatic laser irradiation exerts a bactericidal/fungicidal effect on these microorganisms. The present study clearly demonstrates that 405 nm laser irradiation is a promising alternative management strategy for prevention and/or treatment of endodontic infections.

  7. Radiation

    International Nuclear Information System (INIS)

    Davidson, J.H.

    1986-01-01

    The basic facts about radiation are explained, along with some simple and natural ways of combating its ill-effects, based on ancient healing wisdom as well as the latest biochemical and technological research. Details are also given of the diet that saved thousands of lives in Nagasaki after the Atomic bomb attack. Special comment is made on the use of radiation for food processing. (U.K.)

  8. Incidence of fruit flies on coffee and citrus and quarantine treatment of citrus fruits by gamma radiation

    International Nuclear Information System (INIS)

    Raga, Adalton

    1996-01-01

    The objective of this study was to evaluate the fruit fly infestation on coffee and citrus, and also to determine gamma radiation doses for immature stages of Ceratitis capitata and Anastrepha fraterculus, in order to satisfy quarantine regulations. Coffee arabica varieties Icatu Vermelho, Catuai Amarelo, Mundo Novo and Sarchimor showed the highest infestation indices (pupa/berry): 0.53; 0,41; 0.33 and 0.36. respectively Icatu Vermelho and Catuai Vermelho showed the highest values of pupa/berry weight (0.49 and 0.39, respectively), and Robusta (Coffea canephora) presented the lowest index (0.01). The following fruit flies were found in coffee berries: C. capitata (76.6%) Anastrepha spp. (7.4%) and Lonchaeidae (17.0%). In area near coffee plantation, fruit fly infestation indices in sweet oranges were of 4.77 larvae/kg and 0.55 larva/fruit. The infestation indices for sweet orange, collected from five regions of the State of Sao Paulo ranged from 0.73 to 7.60 pupa/kg and 0.12 to 1.27 pupa/fruit. The same species of fruit flies were found in oranges. In the case of C. capitata eggs with 24-48 hours old, 20 Gy prevented completely adult emergence (artificial diet and orange). No emergence of adult occurred when C. capitata larvae of third instar were irradiated at 20 Gy in their rearing medium. But at 25 Gy, the number of adults was reduced by 54% and 97% from larval infestation in oranges and grapefruit, respectively. A dose of 30 Gy was required to prevent medfly emergence from third instar larvae in grapefruit. A dose of 15 Gy was required for third instar, to prevent adult emergence of A. fraterculus. No adult emerged from C third instar, to prevent adult emergence of A. fraterculus. No adult emerged from C capitata pre-pupa irradiated at 30 Gy. One medfly adult emerged from pupa (3-4 days after pupating) irradiated at 120 Gy. At the same dose, sixteen A. fraterculus adults emergency from irradiated pupa with 5-6 days old. (author)

  9. Dependence of radiation dose on the behavioral patterns among school children. A retrospective analysis 18 to 20 months following the 2011 Fukushima nuclear incident in Japan

    International Nuclear Information System (INIS)

    Nomura, Shuhei; Tsubokura, Masaharu; Kanazawa, Yukio; Oikawa, Tomoyoshi; Furutani, Tomoyuki; Hayano, Ryugo S.; Kami, Masahiro

    2016-01-01

    After radioactive incidents, the exposure risk in daily activities among children is a major public concern. However, there are limited methods available for evaluation of this risk, which is essential to future health risk management. To this end, this study assessed the relationship between behavioral patterns of school children and radiation exposure for a period of 18–20 months following the 2011 Fukushima nuclear incident. The assessed population comprised 520 school children from Minamisoma city, located 20 km north of the nuclear plant. Data for the doses were obtained using individual dosimeters and from results of a behavior survey administered by the City Office. The mean value of the doses in the study period was 0.34 mSv, with a standard deviation of 0.14 mSv, indicating an annual dose of ∼1.36 mSv, which includes doses from natural sources. Our results showed that behavior with respect to outdoor activities had no statistically significant relationship to the dose. A 0.1 μSv/h increase in the air dose rate at home was associated with a 10% increase in the dose; however, a 0.01 μSv/h increase in the air dose rate on the school grounds was associated with a 2% increase in the dose. This study indicates that the air contamination levels at the places where children spend most of their day are the significant predictors of the dose, as opposed to the levels at those outdoor locations in which short periods of time spent. (author)

  10. Incident learning in pursuit of high reliability: implementing a comprehensive, low-threshold reporting program in a large, multisite radiation oncology department.

    Science.gov (United States)

    Gabriel, Peter E; Volz, Edna; Bergendahl, Howard W; Burke, Sean V; Solberg, Timothy D; Maity, Amit; Hahn, Stephen M

    2015-04-01

    Incident learning programs have been recognized as cornerstones of safety and quality assurance in so-called high reliability organizations in industries such as aviation and nuclear power. High reliability organizations are distinguished by their drive to continuously identify and proactively address a broad spectrum of latent safety issues. Many radiation oncology institutions have reported on their experience in tracking and analyzing adverse events and near misses but few have incorporated the principles of high reliability into their programs. Most programs have focused on the reporting and retrospective analysis of a relatively small number of significant adverse events and near misses. To advance a large, multisite radiation oncology department toward high reliability, a comprehensive, cost-effective, electronic condition reporting program was launched to enable the identification of a broad spectrum of latent system failures, which would then be addressed through a continuous quality improvement process. A comprehensive program, including policies, work flows, and information system, was designed and implemented, with use of a low reporting threshold to focus on precursors to adverse events. In a 46-month period from March 2011 through December 2014, a total of 8,504 conditions (average, 185 per month, 1 per patient treated, 3.9 per 100 fractions [individual treatments]) were reported. Some 77.9% of clinical staff members reported at least 1 condition. Ninety-eight percent of conditions were classified in the lowest two of four severity levels, providing the opportunity to address conditions before they contribute to adverse events. Results after approximately four years show excellent employee engagement, a sustained rate of reporting, and a focus on low-level issues leading to proactive quality improvement interventions.

  11. Bunch length measurement using coherent Cherenkov radiation

    International Nuclear Information System (INIS)

    Kan, K.; Yang, J.; Ogata, A.; Kondoh, T.; Norizawa, K.; Yoshida, Y.

    2011-01-01

    A new method for bunch diagnostic based on multimode Coherent Cherenkov Radiation (CCR) was proposed. Generation of quasi-monochromatic terahertz (THz) using multimode CCR on the order of 0.1 THz was carried out. The intensity and frequency of CCR were measured directly by a Michelson interferometer and a bolometer. (author)

  12. In situ electrochemical impedance spectroscopy/synchrotron radiation grazing incidence X-ray diffraction-A powerful new technique for the characterization of electrochemical surfaces and interfaces

    International Nuclear Information System (INIS)

    De Marco, Roland; Jiang, Z.-T.; Martizano, Jay; Lowe, Alex; Pejcic, Bobby; Riessen, Arie van

    2006-01-01

    A marriage of electrochemical impedance spectroscopy (EIS) and in situ synchrotron radiation grazing incidence X-ray diffraction (SR-GIXRD) has provided a powerful new technique for the elucidation of the mechanistic chemistry of electrochemical systems. In this study, EIS/SR-GIXRD has been used to investigate the influence of metal ion buffer calibration ligands, along with natural organic ligands in seawater, on the behaviour of the iron chalcogenide glass ion-selective electrode (ISE). The SR-GIXRD data demonstrated that citrate - a previously reported poor iron calibration ligand for the analysis of seawater - induced an instantaneous and total dissolution of crystalline GeSe and Sb 2 Se 3 in the modified surface layer (MSL) of the ISE, while natural organic ligands in seawater and a mixture of ligands in a mimetic seawater ligand system protected the MSL's crystalline inclusions of GeSe and Sb 2 Se 3 from oxidative attack. Expectedly, the EIS data showed that citrate induced a loss in the medium frequency time constant for the MSL of the ISE, while seawater's natural organic ligands and the mimetic ligand system preserved the medium frequency EIS response characteristics of the ISE's MSL. The new EIS/SR-GIXRD technique has provided insights into the suitability of iron calibration ligands for the analysis of iron in seawater

  13. Propensity-score-matched evaluation of the incidence of radiation pneumonitis and secondary cancer risk for breast cancer patients treated with IMRT/VMAT.

    Science.gov (United States)

    Chao, Pei-Ju; Lee, Hsiao-Fei; Lan, Jen-Hong; Guo, Shih-Sian; Ting, Hui-Min; Huang, Yu-Jie; Chen, Hui-Chun; Lee, Tsair-Fwu

    2017-10-23

    Propensity score matching evaluates the treatment incidence of radiation-induced pneumonitis (RP) and secondary cancer risk (SCR) after intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for breast cancer patients. Of 32 patients treated with IMRT and 58 who received VMAT were propensity matched in a 1:1 ratio. RP and SCR were evaluated as the endpoints of acute and chronic toxicity, respectively. Self-fitted normal tissue complication probability (NTCP) parameter values were used to analyze the risk of RP. SCRs were evaluated using the preferred Schneider's parameterization risk models. The dosimetric parameter of the ipsilateral lung volume receiving 40 Gy (IV 40 ) was selected as the dominant risk factor for the RP NTCP model. The results showed that the risks of RP and NTCP, as well as that of SCR of the ipsilateral lung, were slightly lower than the values in patients treated with VMAT versus IMRT (p ≤ 0.01). However, the organ equivalent dose and excess absolute risk values in the contralateral lung and breast were slightly higher with VMAT than with IMRT (p ≤ 0.05). When compared to IMRT, VMAT is a rational radiotherapy option for breast cancer patients, based on its reduced potential for inducing secondary malignancies and RP complications.

  14. Radiation protection incidents implying individuals that have been indicated to O.P.R.I. in 1998 and 1999; Incidents de radioprotection impliquant des individus signales a l'OPRI en 1998 et 1999

    Energy Technology Data Exchange (ETDEWEB)

    Challeton-de Vathaire, C.; Biau, A.; Boisson, P.; Dubuquoy, E.; Valero, M.; Bourguignon, M. [Office de Protection contre les Rayonnements Ionisants, Dir. Medicale, 78 - le Vesinet (France)

    2001-07-01

    The purpose is to present among the incidents that occurred in 1998 and 1999 these ones susceptible to have consequences in term of external or internal exposure of workers or public members. Only the incidents been the subject of a measurement or a dosimetry individual evaluation have been taken into account in this study. (N.C.)

  15. Low luminance/eyes closed and monochromatic stimulations reduce variability of flash visual evoked potential latency

    Directory of Open Access Journals (Sweden)

    Senthil Kumar Subramanian

    2013-01-01

    Full Text Available Context: Visual evoked potentials are useful in investigating the physiology and pathophysiology of the human visual system. Flash visual evoked potential (FVEP, though technically easier, has less clinical utility because it shows great variations in both latency and amplitude for normal subjects. Aim: To study the effect of eye closure, low luminance, and monochromatic stimulation on the variability of FVEPs. Subjects and Methods: Subjects in self-reported good health in the age group of 18-30 years were divided into three groups. All participants underwent FVEP recording with eyes open and with white light at 0.6 J luminance (standard technique. Next recording was done in group 1 with closed eyes, group 2 with 1.2 and 20 J luminance, and group 3 with red and blue lights, while keeping all the other parameters constant. Two trials were given for each eye, for each technique. The same procedure was repeated at the same clock time on the following day. Statistical Analysis: Variation in FVEP latencies between the individuals (interindividual variability and the variations within the same individual for four trials (intraindividual variability were assessed using coefficient of variance (COV. The technique with lower COV was considered the better method. Results: Recording done with closed eyes, 0.6 J luminance, and monochromatic light (blue > red showed lower interindividual and intraindividual variability in P2 and N2 as compared to standard techniques. Conclusions: Low luminance flash stimulations and monochromatic light will reduce FVEP latency variability and may be clinically useful modifications of FVEP recording technique.

  16. Brain tumors and synchrotron radiation: new methods for mini-beams radiation therapy and treatment follow-up by functional imaging

    International Nuclear Information System (INIS)

    Deman, P.

    2012-01-01

    An innovative method of synchrotron radiation therapy, called mini-beams, was proposed by A. Dilmanian et al. in 2006. Mini-beams consists in tumor irradiation with monochromatic sub-millimetric x-ray beams spatially fractionated produced by a synchrotron source. To obtain a homogeneous dose in the target volume, an interleaving is realized using two orthogonal incidences. Adjacent healthy tissue is only partially irradiated by mini-beams, the areas between the beams only receive scattered radiation and therefore the energy deposited is 10 to 15 times lower than on one mini-beam axis, leading to a sparing effect of healthy tissue even when a high dose is deposited in the target volume. The thesis project is the development of this experimental method of monochromatic mini-beams, which involves the control of the irradiation geometry, the control of dosimetry and its modeling by Monte Carlo simulations. To evaluate the method, preclinical experiments on models of brain tumors implanted in rats (F98) are performed. Follow-up by anatomical and functional imaging is carried out to evaluate the effectiveness of the treatment. Functional imaging of cerebral perfusion (volume and cerebral blood flow, mean transit time of heavy elements) appears to be associated in the literature as a relevant method for monitoring prognostic. The key parameters of the cerebral vasculature are mainly studied in magnetic resonance imaging (MRI), because of the harmlessness of this imaging modality. The relation between MRI signal and contrast agent concentration is very complex and no quantitative relationship is well known. Synchrotron Radiation Computed Tomography (SRCT) is an imaging modality with performances to measure absolute contrast agent concentration very close to the theoretical limits and can be used as gold-standard. The used pharmacokinetic models need as input parameters a contrast agent concentration versus time. A comparison of perfusion measurements between MRI and SRCT

  17. Cliff retreat and sea bed morphology under monochromatic wave forcing: Experimental study

    Science.gov (United States)

    Caplain, Bastien; Astruc, Dominique; Regard, Vincent; Moulin, Frédéric Y.

    2011-07-01

    Wave flume experiments have been performed to investigate a sandy cliff recession under monochromatic wave forcing. We varied the wave climate through the wave energy flux F and the surf similarity parameter ξ. The various processes of the cliff erosion cycle are depicted. The sea bed evolution mostly depends on the surf similarity parameter ξ. Steep planar (ξ > 0.7), gentle planar (0.5 bared (ξ bared profile. However it is similar for both a bared profile and a steep planar profile. The cliff recession rate is not a monotonic function of the cliff height as the type of bottom profile influences the wave energy at the cliff.

  18. Inelastic neutron scattering experiments with the monochromatic imaging mode of the RITA-II spectrometer

    DEFF Research Database (Denmark)

    Bahl, Christian Robert Haffenden; Lefmann, Kim; Abrahamsen, Asger Bech

    2006-01-01

    to perform real inelastic neutron scattering experiments. We present the results from inelastic powder, single crystal dispersion and single crystal constant energy mapping experiments. The advantages and complications of performing these experiments are discussed along with a comparison between the imaging......Recently a monochromatic multiple data taking mode has been demonstrated for diffraction experiments using a RITA type cold neutron spectrometer with a multi-bladed analyser and a position-sensitive detector. Here, we show how this mode can be used in combination with a flexible radial collimator...

  19. Influence of 8 MOP and monochromatic or polychromatic UV light on phagocytosis of neutrophil granulocytes

    International Nuclear Information System (INIS)

    Schaarschmidt, H.; Mueller, M.B.; Knopf, B.; Walther, T.; Rytter, M.; Gast, W.

    1990-01-01

    The inhibition of granulocyte phagocytosis by 8-MOP and monochromatic or polychromatic UV light was investigated. After application of 8-MOP and UV there was an additional inactivation compared with UV alone, as expected from studies on other cell species. This additional inhibition of phagocytosis was found to be increasing with 8-MOP level. The action spectra of granulocyte inactivation by 8-MOP and UV involves the investigated UVB range (until 300 nm). A marked inactivation of granulocytes was seen after erythemogenic fluences only. Therefore it is assumed that inactivation of granulocytes by direct UV action does not play an essential role in UV therapy in vivo. (author)

  20. Mediating surface mode for intensive quasi-monochromatic evanescent wave tunneling

    Science.gov (United States)

    Jia, Zi-xun; Shuai, Yong; Zhang, Jia-hui; Tan, He-ping

    2017-11-01

    In this study, a quasi-monochromatic photon tunneling peak has been achieved in substrate-comb-substrate three bodies system. The near-field tunneling peak results from coupling between spoof surface mode and cavity mode, which has been further amplified by three bodies effect. The spoof surface mode originates from phonon vibration, and is manipulated by the structure into new surface mode. As a non-contact approach to generate high intensity and narrow bandwidth tunneling mode, current study has many application points in near-field spectroscopy and energy-conversion.

  1. Composites with carbon nanotube for radiation shielding application

    International Nuclear Information System (INIS)

    Fontainha, Críssia C.P.; Nunes, Modesto; Rosas, Víctor A.

    2017-01-01

    Polymeric composites filled with attenuating metals and functionalized with carbon nanotubes (NTC) are being largely developed. New attenuators materials have been widely investigated for radiation shielding to apply in procedures as interventional radiology, Computed Tomography (CT) and nuclear medicine. In this work composites for radiation attenuation in radiodiagnostic imaging procedures made of inorganic material as filler, by a sol-gel method, in poly(vinylidene fluoride-tryfluorethylene) [P(VDF-TrFE] copolymers that are used as the polymeric matrix. Two different metal attenuators were used as fillers: zirconia stabilized by yttria (8% wt.) and bismuth oxide. Carbon nanotubes were added with different concentrations at the solution of attenuator metal under controlled magnetic stirring. Characterization of composites by FTIR, UV-Vis, DSC and SEM-EDS were carried out. In a previous analysis of radiation attenuation, was used an incident monochromatic X-ray beam from the RIGAKU diffractometer. In this setup, one reference measure is directly exposed to the x-rays being diffracted by single crystal of Si (111). Another measure the attenuated beam is performed with the composite sample under detector. The functionalization of the carbon nanotube of multiple walls (MWNCT) in the in the P(VDF-TrFE) was evaluated. The samples present a good dispersion of the attenuator metal into presence at methacrylic acid. The cheap tube presented better dispersion in the polymer matrix than the 3100 nanotubes. Bismuth oxidation composites showed a better attenuation factor compared to Zirconia stabilized by yttria composites. (author)

  2. Composites with carbon nanotube for radiation shielding application

    Energy Technology Data Exchange (ETDEWEB)

    Fontainha, Críssia C.P.; Nunes, Modesto; Rosas, Víctor A., E-mail: crissia@gmail.com [Universidade Federal de Minas Gerais (IMA/UFMG), Belo Horizonte, MG (Brazil). Dept. de Anatomia e Imagem; Santos, Adelina P.; Furtado, Clascídia A.; Faria, Luiz O., E-mail: farialo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Polymeric composites filled with attenuating metals and functionalized with carbon nanotubes (NTC) are being largely developed. New attenuators materials have been widely investigated for radiation shielding to apply in procedures as interventional radiology, Computed Tomography (CT) and nuclear medicine. In this work composites for radiation attenuation in radiodiagnostic imaging procedures made of inorganic material as filler, by a sol-gel method, in poly(vinylidene fluoride-tryfluorethylene) [P(VDF-TrFE] copolymers that are used as the polymeric matrix. Two different metal attenuators were used as fillers: zirconia stabilized by yttria (8% wt.) and bismuth oxide. Carbon nanotubes were added with different concentrations at the solution of attenuator metal under controlled magnetic stirring. Characterization of composites by FTIR, UV-Vis, DSC and SEM-EDS were carried out. In a previous analysis of radiation attenuation, was used an incident monochromatic X-ray beam from the RIGAKU diffractometer. In this setup, one reference measure is directly exposed to the x-rays being diffracted by single crystal of Si (111). Another measure the attenuated beam is performed with the composite sample under detector. The functionalization of the carbon nanotube of multiple walls (MWNCT) in the in the P(VDF-TrFE) was evaluated. The samples present a good dispersion of the attenuator metal into presence at methacrylic acid. The cheap tube presented better dispersion in the polymer matrix than the 3100 nanotubes. Bismuth oxidation composites showed a better attenuation factor compared to Zirconia stabilized by yttria composites. (author)

  3. Analysis of the Relation Between Exposure to Ionising Radiation from Computed Tomography Scans in Childhood and Cancer Incidence within the 'Cohorte Enfant Scanner' Study

    International Nuclear Information System (INIS)

    Journy, Neige

    2014-01-01

    Computed tomography (CT) is a powerful imaging technique that provides great benefits for diagnosis and medical management of patients. Nonetheless, the widespread use of this procedure raises many concerns about the potential adverse effects induced by X-rays exposure, both in clinical practice and in terms of public health. First epidemiological studies have suggested an increased risk of cancer associated with CT scan exposures in childhood or adolescence. The interpretation of these results is, however, controversial, and evidence about radiation-induced risks of cancer is still limited at this level of exposure and during childhood. In France, the 'Enfant Scanner' cohort was set up by IRSN to study the incidence of cancer among more than 100,000 children who received CT scans before the age of 10 in 21 university hospitals. This study is part of the European Epi-CT project - coordinated by the International Agency for Research on Cancer - which includes nine national cohorts set up on the basis of a common protocol. The current thesis, based on the French cohort, focuses on characterizing the exposure of children receiving diagnostic CT scans and quantifying the risk of cancer associated with these exposures. Dosimetric assessment was performed from the radiological protocols used in paediatrics between 2000 and 2011 in the participating hospitals. This study presents the evolution of the exposures during the period and the variability of practices in the radiology departments. The results show that there is a leeway for optimizing the procedures and limiting the exposure of patients, especially for scans of the head that account for most of the examinations in paediatrics. A quantitative assessment of cancer risk potentially induced by CT scans in paediatrics was performed - on the basis of estimates of risk in other contexts of ionizing radiation exposure. The results show that each CT scan could be associated with an excess risk of tumours of the

  4. Prophylactic plastic surgery closure of neurosurgical scalp incisions reduces the incidence of wound complications in previously-operated patients treated with bevacizumab (Avastin®) and radiation.

    Science.gov (United States)

    Golas, Alyssa Reiffel; Boyko, Tatiana; Schwartz, Theodore H; Stieg, Philip E; Boockvar, John A; Spector, Jason A

    2014-09-01

    Neurosurgical craniotomy, craniectomy, or other trans-galeal interventions are performed for a variety of indications, including the resection of benign or malignant tumors, hematoma evacuation, and for the management of intractable seizure disorders. Despite an overall low complication rate of intervention, wound healing complications such as dehiscence, surgical site infection, and cerebrospinal fluid leak are not uncommon. A retrospective review was performed of all patients who underwent scalp incision closure at a single institution by a single plastic surgeon between 2006 and 2013. Sixty patients (83 procedures) were included in the study. Fifty-seven patients (95.0 %) underwent previous craniotomy, craniectomy, or other trans-galeal procedure. Of the total 60 patients, 35 patients received preoperative radiation. Sixteen patients received bevacizumab prior to their index case, while 12 received bevacizumab postoperatively. Ten patients (16.7 %) required additional plastic surgical intervention for wound complications after their index plastic surgery procedure. Plastic surgery was consulted prophylactically in 34 patients (38 procedures). When plastic surgery was consulted prophylactically, 4 patients (11.8 %) required further wound revision. None of the 14 patients who underwent prophylactic plastic surgery closure for previous scalp incision, preoperative bevacizumab, and XRT administration required re-intervention. Plastic surgery closure of complex scalp incisions reduces the incidence of wound complications among patients who underwent previous neurosurgical intervention, XRT administration, and preoperative bevacizumab administration. This is particularly true when plastic surgery closure is performed "prophylactically." Further collaboration between the neurosurgical and plastic surgery teams is therefore warranted, particularly in the setting of these high-risk cases.

  5. A compact soft x-ray (0.1–1.2 keV) calibration bench for radiometric measurements using an original versatile Rowland circle grazing incidence monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Hubert, S., E-mail: sebastien.hubert@cea.fr

    2017-05-21

    This paper describes an original Rowland circle grazing incidence spectrometer used as a monochromator for a soft x-ray Manson source in order to calibrate both the source and detectors over the 0.1–1.2 keV spectral range. The originality of the instrument lies on a patented vacuum manipulator which allows the simultaneous boarding of two detectors, one (reference) for measuring the monochromatic radiation and the second to be calibrated. In order to achieve this, the vacuum manipulator is able to interchange, in vacuum, one detector with the other in front of the exit slit of the monochromatizing stage. One purpose of this apparatus was to completely eliminate the intrinsic bremsstrahlung emission of the x-ray diode source and isolate each characteristic line for quantitative detector calibrations. Obtained spectral resolution (Δλ/λ<10{sup −2}) and spectral purity (>98%) fully meet this objective. Initially dimensioned to perform calibration of bulky x-ray cameras unfolded on the Laser MégaJoule Facility, other kinds of detector can be obviously calibrated using this instrument. A brief presentation of the first calibration of an x-ray CCD through its quantum efficiency (QE) measurement is included in this paper as example. Comparison with theoretical model for QE and previous measurements at higher energy are finally presented and discussed.

  6. Monochromatic light-emitting diode (LED source in layers hens during the second production cycle

    Directory of Open Access Journals (Sweden)

    Rodrigo Borille

    2015-09-01

    Full Text Available ABSTRACTLight is an important environmental factor for birds, allowing not only their vision, but also influencing their physiological responses, such as behavioral and reproductive activity. The objective of this experiment was to evaluate the impact of different colors of monochromatic light (LED sources in laying hens production during the second laying cycle. The study was conducted in an experimental laying house during 70 days. A total of 300 laying hens Isa Brown® genetic strain, aged 95 weeks, in the second laying cycle were used in the study. The artificial light sources used were blue, yellow, green, red and white. The light regimen was continuous illumination of 17 h per day (12 h natural and 5 h artificial in a daily light regimen of 17L:5D (light: dark. The Latin Square design was adopted with five treatments (five colors divided into five periods, and five boxes, with six replicates of ten birds in each box. The production and egg quality were evaluated. The different colors of light source did not affect production parameters or egg quality (p > 0.05. The monochromatic light source may be considered as an alternative to artificial lighting in laying hens during the second production cycle.

  7. Towards an Optimized Monochromatization for direct Higgs Production in Future Circular e+ e- Colliders

    CERN Document Server

    García, M A Valdivia

    2017-01-01

    Direct s-channel Higgs production in e+e- collisions is of interest if the centre-of-mass energy spread can be reduced to be comparable to the width of the standard model Higgs boson. A monochromatization principle, previously proposed for several earlier lower-energy colliders, could be employed in order to achieve the desired reduction, by introducing a nonzero horizontal dispersion of opposite sign for the two colliding beams at the interaction point. In high-energy high-luminosity circular colliders, beamstrahlung may increase the energy spread and bunch length. The horizontal emittance blow up due to beamstrahlung, a new effect which was not present in past monochromatization proposals, may degrade the performance, especially the luminosity. We study, for the FCC-ee at 62.5~GeV beam energy, how we can optimize the IP optics parameters, along with the number of particles per bunch so as to obtain maximum luminosity at a desired target value of the collision energy spread.

  8. Radiological incidents in radiotherapy

    International Nuclear Information System (INIS)

    Hobzova, L.; Novotny, J.

    2008-01-01

    In many countries a reporting system of radiological incidents to national regulatory body exists and providers of radiotherapy treatment are obliged to report all major and/or in some countries all incidents occurring in institution. State Office for Nuclear Safety (SONS) is providing a systematic guidance for radiotherapy departments from 1997 by requiring inclusion of radiation safety problems into Quality assurance manual, which is the basic document for obtaining a license of SONS for handling with sources of ionizing radiation. For that purpose SONS also issued the recommendation 'Introduction of QA system for important sources in radiotherapy-radiological incidents' in which the radiological incidents are defined and the basic guidance for their classification (category A, B, C, D), investigation and reporting are given. At regular periods the SONS in co-operation with radiotherapy centers is making a survey of all radiological incidents occurring in institutions and it is presenting obtained information in synoptic communication (2003 Motolske dny, 2005 Novy Jicin). This presentation is another summary report of radiological incidents that occurred in our radiotherapy institutions during last 3 years. Emphasis is given not only to survey and statistics, but also to analysis of reasons of the radiological incidents and to their detection and prevention. Analyses of incidents in radiotherapy have led to a much broader understanding of incident causation. Information about the error should be shared as early as possible during or after investigation by all radiotherapy centers. Learning from incidents, errors and near misses should be a part of improvement of the QA system in institutions. Generally, it is recommended that all radiotherapy facilities should participate in the reporting, analyzing and learning system to facilitate the dissemination of knowledge throughout the whole country to prevent errors in radiotherapy.(authors)

  9. Single source dual energy CT: What is the optimal monochromatic energy level for the analysis of the lung parenchyma?

    Energy Technology Data Exchange (ETDEWEB)

    Ohana, M., E-mail: mickael.ohana@gmail.com [iCube Laboratory, Université de Strasbourg/CNRS, UMR 7357, 67400 Illkirch (France); Service de Radiologie B, Nouvel Hôpital Civil – Hôpitaux Universitaires de Strasbourg, 1 place de l’hôpital, 67000 Strasbourg (France); Labani, A., E-mail: aissam.labani@chru-strasbourg.fr [Service de Radiologie B, Nouvel Hôpital Civil – Hôpitaux Universitaires de Strasbourg, 1 place de l’hôpital, 67000 Strasbourg (France); Severac, F., E-mail: francois.severac@chru-strasbourg.fr [Département de Biostatistiques et d’Informatique Médicale, Hôpital Civil – Hôpitaux Universitaires de Strasbourg,1 place de l’hôpital, 67000 Strasbourg (France); Jeung, M.Y., E-mail: Mi-Young.Jeung@chru-strasbourg.fr [Service de Radiologie B, Nouvel Hôpital Civil – Hôpitaux Universitaires de Strasbourg, 1 place de l’hôpital, 67000 Strasbourg (France); Gaertner, S., E-mail: Sebastien.Gaertner@chru-strasbourg.fr [Service de Médecine Vasculaire, Nouvel Hôpital Civil – Hôpitaux Universitaires de Strasbourg,1 place de l’hôpital, 67000 Strasbourg (France); and others

    2017-03-15

    Highlights: • Lung parenchyma aspect varies with the monochromatic energy level in spectral CT. • Optimal diagnostic and image quality is obtained at 50–55 keV. • Mediastinum and parenchyma could be read on the same monochromatic energy level. - Abstract: Objective: To determine the optimal monochromatic energy level for lung parenchyma analysis in spectral CT. Methods: All 50 examinations (58% men, 64.8 ± 16yo) from an IRB-approved prospective study on single-source dual energy chest CT were retrospectively included and analyzed. Monochromatic images in lung window reconstructed every 5 keV from 40 to 140 keV were independently assessed by two chest radiologists. Based on the overall image quality and the depiction/conspicuity of parenchymal lesions, each reader had to designate for every patient the keV level providing the best diagnostic and image quality. Results: 72% of the examinations exhibited parenchymal lesions. Reader 1 picked the 55 keV monochromatic reconstruction in 52% of cases, 50 in 30% and 60 in 18%. Reader 2 chose 50 keV in 52% cases, 55 in 40%, 60 in 6% and 40 in 2%. The 50 and 55 keV levels were chosen by at least one reader in 64% and 76% of all patients, respectively. Merging 50 and 55 keV into one category results in an optimal setting selected by reader 1 in 82% of patients and by reader 2 in 92%, with a 74% concomitant agreement. Conclusion: The best image quality for lung parenchyma in spectral CT is obtained with the 50–55 keV monochromatic reconstructions.

  10. Statistical analysis of monochromatic whistler waves near the Moon detected by Kaguya

    Directory of Open Access Journals (Sweden)

    Y. Tsugawa

    2011-05-01

    Full Text Available Observations are presented of monochromatic whistler waves near the Moon detected by the Lunar Magnetometer (LMAG on board Kaguya. The waves were observed as narrowband magnetic fluctuations with frequencies close to 1 Hz, and were mostly left-hand polarized in the spacecraft frame. We performed a statistical analysis of the waves to identify the distributions of their intensity and occurrence. The results indicate that the waves were generated by the solar wind interaction with lunar crustal magnetic anomalies. The conditions for observation of the waves strongly depend on the solar zenith angle (SZA, and a high occurrence rate is recognized in the region of SZA between 40° to 90° with remarkable north-south and dawn-dusk asymmetries. We suggest that ion beams reflected by the lunar magnetic anomalies are a possible source of the waves.

  11. An experimental evaluation of monochromatic x-ray beam position monitors at diamond light source

    Energy Technology Data Exchange (ETDEWEB)

    Bloomer, Chris, E-mail: chris.bloomer@diamond.ac.uk; Rehm, Guenther; Dolbnya, Igor P. [Diamond Light Source Ltd, Oxfordshire (United Kingdom)

    2016-07-27

    Maintaining the stability of the X-ray beam relative to the sample point is of paramount importance for beamlines and users wanting to perform cutting-edge experiments. The ability to detect, and subsequently compensate for, variations in X-ray beam position with effective diagnostics has multiple benefits: a reduction in commissioning and start-up time, less ‘down-time’, and an improvement in the quality of acquired data. At Diamond Light Source a methodical evaluation of a selection of monochromatic X-ray Beam Position Monitors (XBPMs), using a range of position detection techniques, and from a range of suppliers, was carried out. The results of these experiments are presented, showing the measured RMS noise on the position measurement of each device for a given flux, energy, beam size, and bandwidth. A discussion of the benefits and drawbacks of each of the various devices and techniques is also included.

  12. An experimental evaluation of monochromatic x-ray beam position monitors at diamond light source

    International Nuclear Information System (INIS)

    Bloomer, Chris; Rehm, Guenther; Dolbnya, Igor P.

    2016-01-01

    Maintaining the stability of the X-ray beam relative to the sample point is of paramount importance for beamlines and users wanting to perform cutting-edge experiments. The ability to detect, and subsequently compensate for, variations in X-ray beam position with effective diagnostics has multiple benefits: a reduction in commissioning and start-up time, less ‘down-time’, and an improvement in the quality of acquired data. At Diamond Light Source a methodical evaluation of a selection of monochromatic X-ray Beam Position Monitors (XBPMs), using a range of position detection techniques, and from a range of suppliers, was carried out. The results of these experiments are presented, showing the measured RMS noise on the position measurement of each device for a given flux, energy, beam size, and bandwidth. A discussion of the benefits and drawbacks of each of the various devices and techniques is also included.

  13. A Preliminary Study on Sources of Banding Artifacts for the Identification of Monochromatic Laser Printers.

    Science.gov (United States)

    Liu, Ning; Zhang, Lichao; Chen, Chuntao

    2017-11-01

    The analysis of questioned documents printed with monochromatic toner has been a great challenge to document examiners. Banding artifacts, which are often perceived in the outputs of laser printers, could be a solution to the identification of printers. In this study, sources other than the gear transmission errors were discovered for some primary banding frequency components. By detecting the angular velocity variation of photosensitive drums and other rotating parts of the tested printers and comparing them with the banding signals extracted from the printouts, the authors located the sources of banding frequency components. It was shown that the sources of some primary and persistent banding signals, which were previously unknown, were traced to the periodic velocity variations of the motors or the timing belts. As inherent signatures, banding artifacts could be promising features for discriminating documents printed by individual laser printers. © 2017 American Academy of Forensic Sciences.

  14. A quasi-monochromatic X-rays source for art painting pigments investigation

    International Nuclear Information System (INIS)

    Albertin, F.; Franconieri, A.; Gambaccini, M.; Petrucci, F.; Chiozzi, S.; Moro, D.

    2009-01-01

    Monochromatic X-ray sources can be used for several applications, like in medicine or in studying our cultural heritage. We are investigating imaging systems based on a tuneable energy band X-ray source, to obtain an element mapping of painting layers using the K-edge technique. The narrow energy band beams are obtained with conventional X-ray source via Bragg diffraction on a mosaic crystal; such an analysis has been performed at different diffraction angles, tuning the energy to investigate spectra of interest from the artistic point of view, like zinc and copper. In this paper the characteristics of the system in terms of fluence rate are reported, and first results of this technique on canvas samples and painting are presented. (orig.)

  15. Electrical properties of SiO2-based graphene under monochromatic visible light irradiation

    Science.gov (United States)

    Li, Xiangdi; Liu, Xianming; Cao, Xueying; Zhang, Peng; Lei, Xiaohua; Chen, Weimin

    2017-08-01

    The purpose of this study is to investigate the electrical properties of graphene transparent conductive film under visible light irradiation. Sample in the study is chemical vapor deposition (CVD) growth graphene on the surface of copper foils and then transferred to the SiO2 substrate. Three monochromatic visible lights with wavelength of 635nm, 520nm and 450nm representing red (R), green (G) and blue (B) lights are used as irradiation sources. Results show that the graphene resistances increase slowly under light irradiation with all the three different wavelengths, while decrease slowly after the light is switched off. Light irradiation with higher power density will induce larger relative resistance change. When graphene is irradiated at the same density, blue light irradiation may result in the largest resistance change.

  16. Influence of laser non-monochromaticity on stimulated Raman scattering in the laser plasma interaction

    International Nuclear Information System (INIS)

    Bonnaud, G.; Reisse, C.

    1986-04-01

    Laser-irradiated plasma were simulated by means of an electromagnetic particle code 1 D 1/2. The aim was to study the influence of the laser wave spectral band width on stimulated Raman scattering. The results given were obtained with two different kinds of laser source: a purely monochromatic wave, used to study the effect of the plasma density, and a source with several distinct frequencies of the same intensity. The main results on the Raman scattering growth rate, the back-scattering and forward-scattering rates and the production of suprathermal electrons are given. The influence of irradiance and ion mobility is investigated. Part of this work was presented at the 14th Anomalous Absorption Conference held in May 1984 at Charlottesville (Virgina - United States) [fr

  17. Treatment of Bell's Palsy Using Monochromatic Infrared Energy: A Report of 2 Cases

    Science.gov (United States)

    Ng, Shu Yan; Chu, Ming Him E.

    2014-01-01

    Objective The purpose of the study is to describe the use of monochromatic infrared energy (MIRE) therapy in the management of 2 patients with Bell's palsy. Clinical features Two patients presented to a chiropractic clinic with Bell's palsy that was diagnosed by a medical physician. Both patients were treated using MIRE. The acute patient was a 32-year-old male. He presented with left facial palsy 1 day before the consultation. He was unable to puff the left cheek and close the left eyelid. He had difficulty raising the left eyebrow. The chronic case was a 46-year-old lady. Prior to the first consultation, she was treated with corticosteroid and electro-acupuncture for one and a half years, with incomplete recovery. When first seen, the left corner of mouth drooped and she had difficulty raising her left eyebrow. Intervention and outcome Monochromatic infrared energy therapy, emitting 890 nm infrared light, was placed on the post-auricular area, pre-auricular area, the temple and mandibular area of the affected side. Each treatment lasted 30 minutes. Photographs were taken every week to document changes. The acute case received 19 treatments in 6 weeks. He reported an improvement of 95%. The chronic case received a total of 45 treatments in 9 months. She rated an improvement of 50%. At the conclusion of treatment, she was able to close her left eyelid and puff her left cheek but still could not raise her left eyebrow. Conclusion These 2 patients seemed to respond to a different degree to the MIRE therapy. As 71% of patients with Bell's palsy recover uneventfully without any treatment, the present study describes the course of care but cannot confirm the effectiveness of MIRE therapy in the management of Bell's palsy. PMID:25685117

  18. Daytime Effect of Monochromatic Blue Light on EEG Activity Depends on Duration and Timing of Exposure in Young Men.

    Science.gov (United States)

    Iskra-Golec, Irena; Golonka, Krystyna; Wyczesany, Miroslaw; Smith, Lawrence; Siemiginowska, Patrycja; Wątroba, Joanna

    2017-01-01

    Growing evidence suggests an alerting effect of monochromatic blue light on brain activity. Little is known about the moderation of those effects by timing and duration of exposure. The present electroencephalography (EEG ) study examined such moderations on delta, theta, alpha1, alpha2, and beta EEG bands. A counterbalanced repeated-measures design was applied. The 16-hr daytime period was divided into three sessions: 07:00-12:20, 12:20-17:40, and 17:40-23:00 (timing of exposure). Two light conditions comparable in luminance but differing in wavelength were applied, namely polychromatic white light and monochromatic blue light (460 nm). There were two durations of exposure-the shorter one lasting 30 min and the longer one lasting 4 hrs. Thirty male students participated in the study. Four factors analyses of variance (ANOV As, for light conditions, timing of exposure, duration of exposure, and brain area) were performed on each EEG band. Results indicated an alerting effect of short exposure to monochromatic blue light at midday and in the evening, which was demonstrated by a decrease in lower frequency bands (alpha1, delta, and theta, respectively). Long exposure to blue light may have a reverse effect, especially in the morning and at midday, when increases in lower frequency bands (theta in the morning and theta and alpha1 at midday) were observed. It can be concluded that the daytime effect of monochromatic blue light on EEG activity depends on timing and duration of exposure.

  19. Contaminated Mexican steel incident

    International Nuclear Information System (INIS)

    1985-01-01

    This report documents the circumstances contributing to the inadvertent melting of cobalt 60 (Co-60) contaminated scrap metal in two Mexican steel foundries and the subsequent distribution of contaminated steel products into the United States. The report addresses mainly those actions taken by US Federal and state agencies to protect the US population from radiation risks associated with the incident. Mexico had much more serious radiation exposure and contamination problems to manage. The United States Government maintained a standing offer to provide technical and medical assistance to the Mexican Government. The report covers the tracing of the source to its origin, response actions to recover radioactive steel in the United States, and return of the contaminated materials to Mexico. The incident resulted in significant radiation exposures within Mexico, but no known significant exposure within the United States. Response to the incident required the combined efforts of the Nuclear Regulatory Commission (NRC), Department of Energy, Department of Transportation, Department of State, and US Customs Service (Department of Treasury) personnel at the Federal level and representatives of all 50 State Radiation Control Programs and, in some instances, local and county government personnel. The response also required a diplomatic interface with the Mexican Government and cooperation of numerous commercial establishments and members of the general public. The report describes the factual information associated with the event and may serve as information for subsequent recommendations and actions by the NRC. 8 figures

  20. Parametric plasma surface instabilities with p-polarized radiation

    International Nuclear Information System (INIS)

    Rappaport, H.L.

    1994-01-01

    The authors argue that parametric plasma surface mode excitation is a viable broadband instability mechanism in the microwave regime since the wavelength of incident radiation can be large compared to plasma ion density gradient scale lengths. The authors restrict their attention to plasmas which are uniform in the planes perpendicular to the density gradients. The boundary region is characterized by three parameters: (1) the ion density gradient length; (2) the electron Debye length; and (3) the excursion of boundary electrons as they move in response to monochromatic p-polarized radiation. A thin vacuum plasma transition layer, in which the ion density gradient scale length is large compared with the Debye length and the electron excursion, is included in the analysis of plasma stability. The recently proposed Lagrangian Frame Two-Plasmon Decay mode (LFTPD) is investigated in the regime in which the instability is not resonantly coupled to surface waves propagating along the boundary region. In this case they have found both spatially dependent growth rate profiles and spatially dependent transit layer magnetic fields due to nonlinear surface currents. LFTPD growth rate profiles are displayed as a function of pump amplitude. The results of a time domain simulation of this mode is also shown

  1. Approximate response of a two-level system to intense multimode radiation

    International Nuclear Information System (INIS)

    Geltman, S.

    1981-01-01

    The rotating wave solution for a two-level atom in an intense monochromatic radiation field is extended by an approximation to the case of a multimode radiation field. Expressions for the resultant average excitation probability of the upper state are presented for rectangular and triangular pulses. (orig.)

  2. Wheelchair incidents

    NARCIS (Netherlands)

    Drongelen AW van; Roszek B; Hilbers-Modderman ESM; Kallewaard M; Wassenaar C; LGM

    2002-01-01

    This RIVM study was performed to gain insight into wheelchair-related incidents with powered and manual wheelchairs reported to the USA FDA, the British MDA and the Dutch Center for Quality and Usability Research of Technical Aids (KBOH). The data in the databases do not indicate that incidents with

  3. Radiation imaging

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.

    1986-05-21

    A detector for the detection of radiation such as X-ray radiation comprises an array of scintillation elements embedded in a sheet of radiation absorbing material. The scintillation elements are monitored individually, for example by a corresponding array of photodiodes, to build up a picture of the incident radiation. The front face of the sheet and the inner walls of the bores may be coated with a reflective material. The detector finds particular application in weld radiography. The detector may be stepped relative to the radiation source, the signals produced by the rows of the detector as they pass a predetermined point being summed.

  4. Radiation imaging

    International Nuclear Information System (INIS)

    Redmayne, Ian.

    1986-01-01

    A detector for the detection of radiation such as X-ray radiation comprises an array of scintillation elements embedded in a sheet of radiation absorbing material. The scintillation elements are monitored individually, for example by a corresponding array of photodiodes, to build up a picture of the incident radiation. The front face of the sheet and the inner walls of the bores may be coated with a reflective material. The detector finds particular application in weld radiography. The detector may be stepped relative to the radiation source, the signals produced by the rows of the detector as they pass a predetermined point being summed. (author)

  5. Laser-plasma SXR/EUV sources: adjustment of radiation parameters for specific applications

    Science.gov (United States)

    Bartnik, A.; Fiedorowicz, H.; Fok, T.; Jarocki, R.; Kostecki, J.; Szczurek, A.; Szczurek, M.; Wachulak, P.; Wegrzyński, Ł.

    2014-12-01

    In this work soft X-ray (SXR) and extreme ultraviolet (EUV) laser-produced plasma (LPP) sources employing Nd:YAG laser systems of different parameters are presented. First of them is a 10-Hz EUV source, based on a double-stream gaspuff target, irradiated with the 3-ns/0.8J laser pulse. In the second one a 10 ns/10 J/10 Hz laser system is employed and the third one utilizes the laser system with the pulse shorten to approximately 1 ns. Using various gases in the gas puff targets it is possible to obtain intense radiation in different wavelength ranges. This way intense continuous radiation in a wide spectral range as well as quasi-monochromatic radiation was produced. To obtain high EUV or SXR fluence the radiation was focused using three types of grazing incidence collectors and a multilayer Mo/Si collector. First of them is a multfoil gold plated collector consisted of two orthogonal stacks of ellipsoidal mirrors forming a double-focusing device. The second one is the ellipsoidal collector being part of the axisymmetrical ellipsoidal surface. Third of the collectors is composed of two aligned axisymmetrical paraboloidal mirrors optimized for focusing of SXR radiation. The last collector is an off-axis ellipsoidal multilayer Mo/Si mirror allowing for efficient focusing of the radiation in the spectral region centered at λ = 13.5 ± 0.5 nm. In this paper spectra of unaltered EUV or SXR radiation produced in different LPP source configurations together with spectra and fluence values of focused radiation are presented. Specific configurations of the sources were assigned to various applications.

  6. A study on application of monochromatic dual energy CT algorithm to polychromatic energy and its acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Sung Ho

    2010-02-15

    Micro CT has been used widely in research fields of specimens and small animals for its ability of non-destructive or in vivo imaging. Micro CT with dual energy options has become particularly important in the preclinical studies such as obesity. In this study a simple post-reconstruction dual energy CT method is proposed. A dual energy CT algorithm for monochromatic x-rays was adopted and applied to the dual energy CT of poly-chromatic x-rays. The algorithm for monochromatic x-rays was implemented and tested with a mathematical phantom. In order to test the sensitivity of this algorithm to errors of x-ray energies values a simulation study was performed with the mathematical phantom. To represent a polychromatic x-ray energy spectrum with a single energy, mean energy of the normalized spectrum and equivalent energy were used as representative energy of polychromatic x-ray. The proposed method was experimentally tested with two different micro CT scanners and a test phantom made of PMMA, water and graphite. CT scans were taken at 40 kV{sub p}, 50 kV{sub p}, 60 kV{sub p}, 70 kV{sub p} and 80 kV{sub p} of energy. The dual energy calculations to extract the effective atomic number (Z{sub eff}) and the electron density information of the phantom materials were carried out with CT images of all energy pairs. The effective atomic number and the electron density values obtained from the proposed method were compared with the theoretical values. The results showed that, using the mean energy to represent a polychromatic spectrum, errors less than 6.0 % in the extracted values can be achieved. Computation acceleration techniques, such as OpenMP and CUDA, were used for fast computation. These techniques reduced computation timeup to a few hundred times. The proposed method showed the simplicity of calculation, practicality and thus the feasibility to use with a general polychromatic CT.

  7. Base substitution spectra of nalidixylate resistant mutations induced by monochromatic soft X and 60Co γ-rays in bacillus subtilis spores

    International Nuclear Information System (INIS)

    Takahashi, Nobuhiro; Hieda, Kotaro; Morohoshi, Fumiko; Munakata, Nobuo

    1999-01-01

    Bacillus subtilis spores were exposed to three types of photons, monochromatic soft X-rays with the energy corresponding to the absorption peak of phosphorus K-shell electron (2,153 eV) and with the slightly lower energy (2,147 eV), and 60 Co γ-rays. From the irradiated spores, 233 mutants exhibiting nalidixic acid resistance were isolated, and together with 94 spontaneous mutants, the sequence changes in the 5'-terminal region of the gyrA gene coding for DNA gyrase subunit A were determined. Among eighteen alleles of the gyrA mutations, eight were single-base substitutions, nine were tandem double-base substitutions, and one was a double substitution skipping a middle base pair. About 6% of the radiation-induced mutations were tandem double-base substitutions, whereas none was observed among the spontaneous ones. Among spontaneous mutations, A:T and G:C pairs were equally subjected to mutations, whereas the substitutions from G:C pairs and those to A:T pairs predominated among those induced with soft X-rays. The peak-energy X-rays were more effective in killing and causing mutations than the low-energy X-rays, however, there seemed no base-change events uniquely attributable to phosphorus K-shell absorption. (author)

  8. The Quasi-monochromatic ULF Wave Boundary in the Venusian Foreshock: Venus Express Observations

    Science.gov (United States)

    Shan, Lican; Mazelle, Christian; Meziane, Karim; Romanelli, Norberto; Ge, Yasong S.; Du, Aimin; Lu, Quanming; Zhang, Tielong

    2018-01-01

    The location of ultralow-frequency (ULF) quasi-monochromatic wave onset upstream of Venus bow shock is explored using Venus Express magnetic field data. We report the existence of a spatial foreshock boundary behind which ULF waves are present. We have found that the ULF wave boundary at Venus is sensitive to the interplanetary magnetic field (IMF) direction like the terrestrial one and appears well defined for a cone angle larger than 30°. In the Venusian foreshock, the inclination angle of the wave boundary with respect to the Sun-Venus direction increases with the IMF cone angle. We also found that for the IMF nominal direction (θBX = 36°) at Venus' orbit, the value of this inclination angle is 70°. Moreover, we have found that the inferred velocity of an ion traveling along the ULF boundary is in a qualitative agreement with a quasi-adiabatic reflection of a portion of the solar wind at the bow shock. For an IMF nominal direction at Venus, the inferred bulk speed of ions traveling along this boundary is 1.07 VSW, sufficiently enough to overcome the solar wind convection. This strongly suggests that the backstreaming ions upstream of the Venusian bow shock provide the main energy source for the ULF waves.

  9. Using monochromatic design views to avoid a premature fixation on design solutions.

    Science.gov (United States)

    Damle, Amod

    2010-02-01

    This study investigates whether the availability of a monochromatic design view can prevent an early fixation on details during the preliminary stages of a design task. Design students are trained to tentatively sketch the overall form of a design concept before attending to its details. Literature suggests that using multiple colors for sketching a concept causes a gestalt-like grouping phenomenon and influences designers to adopt a contrasting strategy of adding details before sketching the overall form. An empirical study was conducted to assess the validity of these findings. In the study, 20 participants, randomly assigned to two groups, were allowed to use multiple colors to sketch a design concept within a digital sketching environment. However, only the single-color group had the ability to view a sketch, as it would appear in monochrome. Both groups parsed the design concepts into their basic components and used colors as a means of distinguishing one component from another. However, the single-color group added significantly more details than the first or the multicolor group after sketching the overall form. Verbal reports suggest that the single-color group was able to avoid an early fixation on details because the single-color view eliminated the discontinuities induced by the variation in color and allowed the participants to attend to the overall form instead of the individual components. The current findings highlight the importance of providing a monochrome design view within a sketching environment to avoid an early fixation on a specific design solution.

  10. Experimental and Numerical Studies on Wave Breaking Characteristics over a Fringing Reef under Monochromatic Wave Conditions

    Directory of Open Access Journals (Sweden)

    Jong-In Lee

    2014-01-01

    Full Text Available Fringing reefs play an important role in protecting the coastal area by inducing wave breaking and wave energy dissipation. However, modeling of wave transformation and energy dissipation on this topography is still difficult due to the unique structure. In the present study, two-dimensional laboratory experiments were conducted to investigate the cross-shore variations of wave transformation, setup, and breaking phenomena over an idealized fringing reef with the 1/40 reef slope and to verify the Boussinesq model under monochromatic wave conditions. One-layer and two-layer model configurations of the Boussinesq model were used to figure out the model capability. Both models predicted well (r2>0.8 the cross-shore variation of the wave heights, crests, troughs, and setups when the nonlinearity is not too high (A0/h0<0.07 in this study. However, as the wave nonlinearity and steepness increase, the one-layer model showed problems in prediction and stability due to the error on the vertical profile of fluid velocity. The results in this study revealed that one-layer model is not suitable in the highly nonlinear wave condition over a fringing reef bathymetry. This data set can contribute to the numerical model verification.

  11. Quasi-Monochromatic Flash X-Ray Generator Utilizing Disk-Cathode Molybdenum Tube

    Science.gov (United States)

    Sato, Eiichi; Sagae, Michiaki; Tanaka, Etsuro; Hayasi, Yasuomi; Germer, Rudolf; Mori, Hidezo; Kawai, Toshiaki; Ichimaru, Toshio; Sato, Shigehiro; Takayama, Kazuyoshi; Ido, Hideaki

    2004-10-01

    High-voltage condensers in a polarity-inversion two-stage Marx surge generator are charged from -40 to -60 kV using a power supply, and the electric charges in the condensers are discharged to an X-ray tube after closing the gap switches in the surge generator using a trigger device. The X-ray tube is a demountable diode, and the turbomolecular pump evacuates air from the tube with a pressure of approximately 1 mPa. Sharp K-series characteristic X-rays of molybdenum are produced without using a monochromatic filter, since the tube utilizes a disk cathode and a rod target, and bremsstrahlung rays are not emitted in the opposite direction to that of electron acceleration. The peak tube voltage increased with increasing charging voltage and increasing space between the target and cathode electrodes. At a charging voltage of -60 kV and a target-cathode space of 1.0 mm, the peak tube voltage and current were 110 kV and 0.75 kA, respectively. The pulse width ranged from 40 to 100 ns, and the maximum dimension of the X-ray source was 3.0 mm in diameter. The number of generator-produced K photons was approximately 7× 1014 photons/cm2\\cdots at 0.5 m from the source.

  12. A Photodegradation Study of Three Common Paint and Plaster Biocides under monochromatic UV Light

    DEFF Research Database (Denmark)

    Minelgaite, Greta; Vollertsen, Jes; Nielsen, Asbjørn Haaning

    2014-01-01

    Photodegradation of the three common paint-and-plaster biocides (carbendazim, diuron and terbutryn) was investigated at controlled laboratory conditions. Samples prepared in two types of water (demineralized water and pond water) were subjected to 254 nm monochromatic UV light. Light intensity (W m...... results demonstrated that diuron and terbutryn were readily degradable at the tested conditions, while carbendazim remained stable throughout the 28 – 34 hours of the experiments. Photodegradation rate constants of diuron and terbutryn were found to be slightly higher in demineralized water (0.0183 – 0.......0227 m2 kJ-1 and 0.0279 – 0.0341 m2 kJ-1 for diuron and terbutryn, respectively) compared with pond water (0.0152 – 0.02 m2 kJ-1 and 0.0233 – 0.0283 m2 kJ-1 for diuron and terbutryn, respectively). The findings of this study demonstrate the general photodegradation tendencies of the three biocides...

  13. Modulatory Effect of Monochromatic Blue Light on Heat Stress Response in Commercial Broilers.

    Science.gov (United States)

    Abdo, Safaa E; El-Kassas, Seham; El-Nahas, Abeer F; Mahmoud, Shawky

    2017-01-01

    In a novel approach, monochromatic blue light was used to investigate its modulatory effect on heat stress biomarkers in two commercial broiler strains (Ross 308 and Cobb 500). At 21 days old, birds were divided into four groups including one group housed in white light, a second group exposed to blue light, a 3rd group exposed to white light + heat stress, and a 4th group exposed to blue light + heat stress. Heat treatment at 33°C lasted for five h for four successive days. Exposure to blue light during heat stress reduced MDA concentration and enhanced SOD and CAT enzyme activities as well as modulated their gene expression. Blue light also reduced the degenerative changes that occurred in the liver tissue as a result of heat stress. It regulated, though variably, liver HSP70 , HSP90 , HSF1 , and HSF3 gene expression among Ross and Cobb chickens. Moreover, the Cobb strain showed better performance than Ross manifested by a significant reduction of rectal temperature in the case of H + B. Furthermore, a significant linear relationship was found between the lowered rectal temperature and the expression of all HSP genes. Generally, the performance of both strains by most assessed parameters under heat stress is improved when using blue light.

  14. On the stochastic interaction of monochromatic Alfven waves with toroidally trapped particles

    International Nuclear Information System (INIS)

    Krlin, L.; Pavlo, P.; Tluchor, Z.; Gasek, Z.

    1987-07-01

    Monochromatic Alfven wave interaction with toroidaly trapped particles in the intrinsic stochasticity regime is discussed. Both the diffusion in velocities and in the radial position of bananas is studied. Using a suitable Hamiltonian formalism, the effect of wave parallel components E-tilde paral and B-tilde paral is investigated. The stochasticity threshold is estimated for plasma electrons and for thermonuclear alpha-particles (neglecting the effect of B-tilde paral ) by means of direct numerical integration of the corresponding canonical equations. Stochasticity causes transfer between trapped and untrapped regimes and the induced radial diffusion of bananas. The latter effect can considerably exceed neoclassical diffusion. The effect of B-tilde paral was only estimated analytically. It consisted in frequency modulation of the banana periodic motion coupled with a possible Mathieu instability. Nevertheless, for B-tilde paral corresponding to E-tilde paral , the effect seems to be weaker than the effect of E-tilde paral when the thermonuclear regime is considered. (author). 14 figs., 36 refs

  15. Conceptual Design of Dielectric Accelerating Structures for Intense Neutron and Monochromatic X-ray Sources

    Science.gov (United States)

    Blanovsky, Anatoly

    2004-12-01

    Bright compact photon sources, which utilize electron beam interaction with periodic structures, may benefit a broad range of medical, industrial and scientific applications. A class of dielectric-loaded periodic structures for hard and soft X-ray production has been proposed that would provide a high accelerating gradient when excited by an external RF and/or primary electron beam. Target-distributed accelerators (TDA), in which an additional electric field compensates for lost beam energy in internal targets, have been shown to provide the necessary means to drive a high flux subcritical reactor (HFSR) for nuclear waste transmutation. The TDA may also be suitable for positron and nuclear isomer production, X-ray lithography and monochromatic computer tomography. One of the early assumptions of the theory of dielectric wake-field acceleration was that, in electrodynamics, the vector potential was proportional to the scalar potential. The analysis takes into consideration a wide range of TDA design aspects including the wave model of observed phenomena, a layered compound separated by a Van der Waals gap and a compact energy source based on fission electric cells (FEC) with a multistage collector. The FEC is a high-voltage power source that directly converts the kinetic energy of the fission fragments into electrical potential of about 2MV.

  16. Simulation and analysis of time-gated monochromatic radiographs of cryogenic implosions on OMEGA

    Science.gov (United States)

    Epstein, R.; Stoeckl, C.; Goncharov, V. N.; McKenty, P. W.; Marshall, F. J.; Regan, S. P.; Betti, R.; Bittle, W.; Harding, D. R.; Hu, S. X.; Igumenshchev, I. V.; Jacobs-Perkins, D.; Janezic, R. T.; Kelly, J. H.; Kosc, T. Z.; Mileham, C.; Morse, S. F. B.; Radha, P. B.; Rice, B.; Sangster, T. C.; Shoup, M. J., III; Shmayda, W. T.; Sorce, C.; Ulreich, J.; Wittman, M. D.

    2017-06-01

    Spherical polymer shells containing cryogenic DT ice layers have been imploded on the OMEGA Laser System and radiographed using Si backlighter targets (hν = 1.865 keV) driven with 20-ps IR pulses from the OMEGA EP Laser System. We report on a series of implosions in which the deuterium-tritium (DT) shell is imaged for a range of convergence ratios and in-flight aspect ratios. The shadows of the converging DT ice and polymer shells are recorded while the self-emission is minimized using a time-resolved (40-ps) monochromatic crystal imaging system. The images acquired have been analyzed for the level of ablator mixing into the DT fuel (even 0.1% of carbon mix can be reliably inferred). Simulations are compared with measured x-ray radiographs to provide insight into the early time and stagnation stages of an implosion, to guide the modeling efforts to improve the target designs, and to guide the development of this and other imagining techniques, such as Compton radiography.

  17. SNAPSHOT SPECTRAL AND COLOR IMAGING USING A REGULAR DIGITAL CAMERA WITH A MONOCHROMATIC IMAGE SENSOR

    Directory of Open Access Journals (Sweden)

    J. Hauser

    2017-10-01

    Full Text Available Spectral imaging (SI refers to the acquisition of the three-dimensional (3D spectral cube of spatial and spectral data of a source object at a limited number of wavelengths in a given wavelength range. Snapshot spectral imaging (SSI refers to the instantaneous acquisition (in a single shot of the spectral cube, a process suitable for fast changing objects. Known SSI devices exhibit large total track length (TTL, weight and production costs and relatively low optical throughput. We present a simple SSI camera based on a regular digital camera with (i an added diffusing and dispersing phase-only static optical element at the entrance pupil (diffuser and (ii tailored compressed sensing (CS methods for digital processing of the diffused and dispersed (DD image recorded on the image sensor. The diffuser is designed to mix the spectral cube data spectrally and spatially and thus to enable convergence in its reconstruction by CS-based algorithms. In addition to performing SSI, this SSI camera is capable to perform color imaging using a monochromatic or gray-scale image sensor without color filter arrays.

  18. A review of monochromatic light devices for the treatment of alopecia areata.

    Science.gov (United States)

    Darwin, Evan; Arora, Harleen; Hirt, Penelope A; Wikramanayake, Tongyu Cao; Jimenez, Joaquin J

    2018-02-01

    There are many laser technologies that are being tested that claim to support hair regrowth for patients with alopecia areata (AA). In this paper, we will determine whether the body of evidence supports the use of devices using monochromatic light sources to treat AA. Articles were gathered from PubMed, Embase, and the Cochrane database using these keywords: lasers, excimer laser, low-level laser therapy (LLLT), low-level light therapy, alopecia, alopecia areata, and hair loss with a category modifier of English. Ten clinical trials and seven case reports/abstracts were assessed. Eight clinical trials and two case reports demonstrated hair regrowth with the 308-nm excimer laser/light in men, women, and children. One case report demonstrated hair regrowth with the ALBA 355® laser. One clinical trial and two case reports demonstrated hair regrowth with LLLT. While two case reports demonstrated hair regrowth with fractional laser therapy, one clinical trial showed no improvement. The 308-nm excimer laser is a safe and effective treatment for men, women, and children with refractory AA of the scalp and beard. Larger, double-blinded clinical trials should be conducted to compare excimer laser therapy to standard treatments. More data is needed to determine the efficacy of LLLT and fractional laser therapy in the treatment of AA.

  19. Defect generation in silicon dioxide from synchrotron radiation below 41 eV

    International Nuclear Information System (INIS)

    Williams, C.K.; Reisman, A.; Bhattacharya, P.

    1989-01-01

    Generation of fixed positive charge, neutral electron traps, and fixed negative charge in SiO 2 due to exposure to x radiation in the photon energy range below 41 eV from a synchrotron source is reported. For constant incident x-radiation exposure levels of 120 mJ/cm 2 with both monochromatic and broadband radiation, the number of defects generated in the monitoring devices was at or below the detection limit of the equipment. This is in sharp contrast with the results obtained at photon energies above 300 eV reported earlier [C. K. Williams, A. Reisman, P. K. Bhattacharya, and W. Ng, J. Appl. Phys. 64, 1145 (1988)] in which a large number of each of the three defects mentioned above were generated. The lack of damage indicates that the problems associated with x-ray-induced insulator damage due to x-ray lithography may be solved by tailoring the photon energy, provided suitable mask and photoresist materials can be developed

  20. Comparison of virtual monochromatic series, iodine overlay maps, and single energy CT equivalent images in head and neck cancer conspicuity.

    Science.gov (United States)

    Kraft, Michael; Ibrahim, Mohannad; Spector, Matthew; Forghani, Reza; Srinivasan, Ashok

    2017-09-29

    To compare lesion conspicuity amongst DECT monochromatic series (40, 45, 50keV), and single-energy CT (SECT) equivalent images in head and neck squamous cell carcinomas (HNSCC). Two readers compared DECT images to 70keV SECT equivalent series in 39 patients with HNSCC on lesion margin, enhancement, and overall conspicuity. The 45keV and 50keV images were significantly better (p-values ≤0.001) than the SECT equivalent in lesion enhancement, margins, and overall conspicuity for both readers. Readers mostly preferred the 50keV monochromatic series. DECT can provide better lesion visualization than SECT in HNSCC. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Metal artifacts reduction using monochromatic images from spectral CT: Evaluation of pedicle screws in patients with scoliosis

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yang, E-mail: wangzhang227@163.com [Department of Radiology, The Affiliated Nanjing Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008 (China); Qian, Bangping, E-mail: qianbangping@163.com [Spine Service, Drum Tower Hospital, Nanjing University Medical School, Nanjing 210008 (China); Li, Baoxin, E-mail: wangzhi68@163.com [Department of Radiology, The Affiliated Nanjing Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008 (China); Qin, Guochu, E-mail: qgc7605@yahoo.com.cn [Department of Radiology, The Affiliated Nanjing Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008 (China); Zhou, Zhengyang, E-mail: zyzhou@nju.edu.cn [Department of Radiology, The Affiliated Nanjing Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008 (China); Qiu, Yong, E-mail: scoliosis2002@sina.com [Spine Service, Drum Tower Hospital, Nanjing University Medical School, Nanjing 210008 (China); Sun, Xizhao, E-mail: sunxizhaonj@163.com [Department of Radiology and Urology, The Affiliated Nanjing Drum Tower Hospital of Nanjing University Medical School, No. 321 Zhongshan Road, Nanjing 210008 (China); Zhu, Bin, E-mail: gobin10266@163.com [Department of Radiology, The Affiliated Nanjing Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008 (China)

    2013-08-15

    Purpose: To evaluate the effectiveness of spectral CT in reducing metal artifacts caused by pedicle screws in patients with scoliosis. Materials and methods: Institutional review committee approval and written informed consents from patients were obtained. 18 scoliotic patients with a total of 228 pedicle screws who underwent spectral CT imaging were included in this study. Monochromatic image sets with and without the additional metal artifacts reduction software (MARS) correction were generated with photon energy at 65 keV and from 70 to 140 keV with 10 keV interval using the 80 kVp and 140 kVp projection sets. Polychromatic images corresponded to the conventional 140 kVp imaging were also generated from the same scan data as a control group. Both objective evaluation (screw width and quantitative artifacts index measurements) and subjective evaluation (depiction of pedicle screws, surrounding structures and their relationship) were performed. Results: Image quality of monochromatic images in the range from 110 to 140 keV (0.97 ± 0.28) was rated superior to the conventional polychromatic images (2.53 ± 0.54) and also better than monochromatic images with lower energy. Images of energy above 100 keV also give accurate measurement of the width of screws and relatively low artifacts index. The form of screws was slightly distorted in MARS reconstruction. Conclusions: Compared to conventional polychromatic images, monochromatic images acquired from dual-energy CT provided superior image quality with much reduced metal artifacts of pedicle screws in patients with scoliosis. Optimal energy range was found between 110 and 140 keV.

  2. Energy-angle correlation correction algorithm for monochromatic computed tomography based on Thomson scattering X-ray source

    Science.gov (United States)

    Chi, Zhijun; Du, Yingchao; Huang, Wenhui; Tang, Chuanxiang

    2017-12-01

    The necessity for compact and relatively low cost x-ray sources with monochromaticity, continuous tunability of x-ray energy, high spatial coherence, straightforward polarization control, and high brightness has led to the rapid development of Thomson scattering x-ray sources. To meet the requirement of in-situ monochromatic computed tomography (CT) for large-scale and/or high-attenuation materials based on this type of x-ray source, there is an increasing demand for effective algorithms to correct the energy-angle correlation. In this paper, we take advantage of the parametrization of the x-ray attenuation coefficient to resolve this problem. The linear attenuation coefficient of a material can be decomposed into a linear combination of the energy-dependent photoelectric and Compton cross-sections in the keV energy regime without K-edge discontinuities, and the line integrals of the decomposition coefficients of the above two parts can be determined by performing two spectrally different measurements. After that, the line integral of the linear attenuation coefficient of an imaging object at a certain interested energy can be derived through the above parametrization formula, and monochromatic CT can be reconstructed at this energy using traditional reconstruction methods, e.g., filtered back projection or algebraic reconstruction technique. Not only can monochromatic CT be realized, but also the distributions of the effective atomic number and electron density of the imaging object can be retrieved at the expense of dual-energy CT scan. Simulation results validate our proposal and will be shown in this paper. Our results will further expand the scope of application for Thomson scattering x-ray sources.

  3. Polychromatic excitation improves detection limits in total reflection X-ray fluorescence analysis compared with monochromatic excitation.

    Science.gov (United States)

    Kunimura, Shinsuke; Kawai, Jun

    2010-08-01

    Detection limits obtained by a portable total reflection X-ray fluorescence (TXRF) spectrometer with or without a monochromator are compared. A 1 W X-ray tube (tube voltage: 20 kV) is used in this spectrometer. Polychromatic excitation improves the detection limits in TXRF analysis with the low power X-ray tube compared with monochromatic excitation. A detection limit of 26 pg is achieved for Co when using the weak polychromatic X-rays.

  4. Incidents analysis

    International Nuclear Information System (INIS)

    Francois, P.

    1996-01-01

    We undertook a study programme at the end of 1991. To start with, we performed some exploratory studies aimed at learning some preliminary lessons on this type of analysis: Assessment of the interest of probabilistic incident analysis; possibility of using PSA scenarios; skills and resources required. At the same time, EPN created a working group whose assignment was to define a new approach for analysis of incidents on NPPs. This working group gave thought to both aspects of Operating Feedback that EPN wished to improve: Analysis of significant incidents; analysis of potential consequences. We took part in the work of this group, and for the second aspects, we proposed a method based on an adaptation of the event-tree method in order to establish a link between existing PSA models and actual incidents. Since PSA provides an exhaustive database of accident scenarios applicable to the two most common types of units in France, they are obviously of interest for this sort of analysis. With this method we performed some incident analyses, and at the same time explores some methods employed abroad, particularly ASP (Accident Sequence Precursor, a method used by the NRC). Early in 1994 EDF began a systematic analysis programme. The first, transient phase will set up methods and an organizational structure. 7 figs

  5. Biologically based analysis of lung cancer incidence in a large Canadian occupational cohort with low-LET low-dose radiation exposure, and comparison with Japanese atomic bomb survivors

    International Nuclear Information System (INIS)

    Hazelton, W.D.; Curtis, S.B.; Moolgavkar, S.H.; Hutchinson, F.; Krewski, D.

    2003-01-01

    Lung cancer incidence is analyzed in a large Canadian National Dose Registry (CNDR) cohort with individual annual dosimetry for low-dose occupational exposure to gamma and tritium radiation using several types of multistage models. The primary analysis utilizes the two-stage clonal expansion model (TSCE), with sensitivity analyses using extensions of this model incorporating additional stages. Characteristic and distinct temporal patterns of risk are found for dose-response affecting early, middle, or late stages of carcinogenesis, e.g. initiation with one or more stages, clonal expansion, or malignant conversion. Fixed lag or lag distributions are used to model time from first malignant cell to incidence. Background rates are analyzed by gender, job classification and birth cohort. Lacking individual smoking data, surrogate doses based on US annual per capita cigarette consumption appear to account for much of the birth cohort effect. Males, with mean cumulative exposure for gamma and tritium of 11.5 mSv and 322 incident lung cancer cases have a significant dose-response with 33 cases attributable to radiation. Female dose-response, with mean cumulative exposure of 1.7 mSv and 78 incident cases, appears similar but is not statistically significant. Findings for males include an inverse-dose-rate effect (increased risk with protraction of a given dose) and dose-response effects on initiation, promotion and malignant conversion, although the effect on initiation is not statistically significant. The excess relative risk (ERR) and excess absolute risk (EAR) depend on age at exposure, duration, dose, and age at follow-up. The ERR increases with dose, tapering off at higher doses, making a plot of ERR against dose concave-downward, similar to apparent low-dose results seen below 1 Sv for solid tumor mortality of atomic bomb survivors. The concave-downward trend of ERR and the inverse-dose-rate effect are both counter to prevailing beliefs about effects of low

  6. Impact of curcumin supplementation in monochromatic light on lipid serum profile of sexually mature female Magelang ducks

    Directory of Open Access Journals (Sweden)

    K. Kasiyati

    2018-03-01

    Full Text Available An experiment was conducted to study the effect of curcumin supplementation inexpose monochromatic light on serum lipid concentrations of sexually mature female magelang duck. One hundred and ninety two female magelang ducks were assigned into a completely randomized design with a 4×4 factorial arrangement and each experimental unit was repeated 3 times, each with 4 female magelang ducks. The first factor was dose of curcumin supplementation consisted of 4 levels i.e., 0, 9, 18, and 36 mg/duck/day. The second factor was the color of monochromatic light consisted of 4 levels i.e., white, red, green, and blue colors. The data were analyzed by two-way ANOVA. The result showed that serum concentrations of triglyceride, cholesterol, very low density lipoprotein (VLDL, and low density lipoprotein (LDL were lower (P<0.05 while high density lipoprotein (HDL were higher (P<0.05 in experimental ducks supplemented with a curcumin dose of 36 mg/duck/day in variety of monochromatic light colors compared to control experimental ducks without curcumin supplementation. The curcumin doses of 18 or 36 mg/duck/day within red, green, or blue light had the potential to modulate lipid metabolism, as indicated by the increased serum concentration of HDL and the decreased serum concentrations of triglyceride, cholesterol, VLDL, and LDL of the experimental female magelang ducks.

  7. Photofission of {sup NAT} Pt by monochromatic and polarized photons in the quasi-deuteron region; Fotofissao da {sup NAT} Pt por fotons monocromaticos e polarizados na regiao do quase-deuteron

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Eduardo de

    1992-01-01

    The measurement of the Nat Pt photofission yield at 69 MeV of effective average energy of the incident photon is made using a polarized and monochromatic photon beam from the LADON system of the National Laboratory of Frascati, Italy, produced by inverse Compton scattering of laser light by high energy electrons of the ADONE Accelerator and using as fission track solid detector the Makrofol, being the developing made by usual procedure. The experimental value of the nuclear fissionability is compared to a theoretical value obtained following a model at two stages: in the first, the photon energy is absorbed by a neutron-proton pair inducing to the nucleus excitation, and in the second the nucleus de-excites due to the competition between nucleon evaporation and fission. The effect of fast nucleon emission during the first stage and the successive evaporation of neutrons in the second stage are considered. 40 refs, 12 figs, 9 tabs.

  8. Incident air kerma to absorbed organ dose conversion factors for breast and lung in PA thorax radiography: The effect of patient thickness and radiation quality.

    Science.gov (United States)

    Kelaranta, A; Toroi, P; Vock, P

    2016-12-01

    Converting the measurable quantities to patient organ doses in projection radiography is usually based on a standard-sized patient model and a specific radiation quality, which are likely to differ from the real situation. Large inaccuracies can therefore be obtained in organ doses, because organ doses are dependent on the exposure parameters, exposure geometry and patient anatomy. In this study, the effect of radiation quality and patient thickness on the organ dose conversion factors were determined. In this study, the posterior-anterior projection radiograph of the thorax was selected in order to determine the effect of radiation quality (tube voltages of 70-130kV and total filtrations of 3mmAl to 4mmAl+0.2 mmCu) and patient thickness (anterior-posterior thicknesses of 19.4-30.8cm) on the breast and lung dose conversion factors. For this purpose, Monte Carlo simulation programs ImpactMC and PCXMC were used with computed tomography examination data of adult male and female patients and mathematical hermaphrodite phantoms, respectively. Compared to the reference beam quality and patient thickness, the relative variation range in organ dose conversion factors was up to 74% for different radiation qualities and 122% for different patient thicknesses. Conversion factors should only be used with comprehensive understanding of the exposure conditions, considering the exposure parameters, exposure geometry and patient anatomy they are valid for. This study demonstrates that patient thickness-specific and radiation quality-specific conversion factors are needed in projection radiography. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. SU-D-BRA-06: Dual-Energy Chest CT: The Effects of Virtual Monochromatic Reconstructions On Texture Analysis Features

    Energy Technology Data Exchange (ETDEWEB)

    Sorensen, J; Duran, C; Stingo, F; Wei, W; Rao, A; Zhang, L; Court, L; Erasmus, J; Godoy, M [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To characterize the effect of virtual monochromatic reconstructions on several commonly used texture analysis features in DECT of the chest. Further, to assess the effect of monochromatic energy levels on the ability of these textural features to identify tissue types. Methods: 20 consecutive patients underwent chest CTs for evaluation of lung nodules using Siemens Somatom Definition Flash DECT. Virtual monochromatic images were constructed at 10keV intervals from 40–190keV. For each patient, an ROI delineated the lesion under investigation, and cylindrical ROI’s were placed within 5 different healthy tissues (blood, fat, muscle, lung, and liver). Several histogram- and Grey Level Cooccurrence Matrix (GLCM)-based texture features were then evaluated in each ROI at each energy level. As a means of validation, these feature values were then used in a random forest classifier to attempt to identify the tissue types present within each ROI. Their predictive accuracy at each energy level was recorded. Results: All textural features changed considerably with virtual monochromatic energy, particularly below 70keV. Most features exhibited a global minimum or maximum around 80keV, and while feature values changed with energy above this, patient ranking was generally unaffected. As expected, blood demonstrated the lowest inter-patient variability, for all features, while lung lesions (encompassing many different pathologies) exhibited the highest. The accuracy of these features in identifying tissues (76% accuracy) was highest at 80keV, but no clear relationship between energy and classification accuracy was found. Two common misclassifications (blood vs liver and muscle vs fat) accounted for the majority (24 of the 28) errors observed. Conclusion: All textural features were highly dependent on virtual monochromatic energy level, especially below 80keV, and were more stable above this energy. However, in a random forest model, these commonly used features were

  10. Bounce-averaged advection and diffusion coefficients for monochromatic electromagnetic ion cyclotron wave: Comparison between test-particle and quasi-linear models

    Science.gov (United States)

    Su, Z.; Zhu, H.; Xiao, F.; Zheng, H.; Shen, C.; Wang, Y.; Wang, S.

    2012-12-01

    The electromagnetic ion cyclotron (EMIC) wave has been long suggested to be responsible for the rapid loss of radiation belt relativistic electrons. The test-particle simulations are performed to calculate the bounce-averaged pitch-angle advection and diffusion coefficients for parallel-propagating monochromatic EMIC waves. The comparison between test-particle (TP) and quasi-linear (QL) transport coefficients is further made to quantify the influence of nonlinear processes. For typical EMIC waves, four nonlinear physical processes, i.e., the boundary reflection effect, finite perturbation effect, phase bunching and phase trapping, are found to occur sequentially from small to large equatorial pitch angles. The pitch-angle averaged finite perturbation effect yields slight differences between the transport coefficients of TP and QL models. The boundary reflection effect and phase bunching produce an average reduction of >80% in the diffusion coefficients but a small change in the corresponding average advection coefficients, tending to lower the loss rate predicted by QL theory. In contrast, the phase trapping causes continuous negative advection toward the loss cone and a minor change in the corresponding diffusion coefficients, tending to increase the loss rate predicted by QL theory. For small amplitude EMIC waves, the transport coefficients grow linearly with the square of wave amplitude. As the amplitude increases, the boundary reflection effect, phase bunching and phase trapping start to occur. Consequently, the TP advection coefficients deviate from the linear growth with the square of wave amplitude, and the TP diffusion coefficients become saturated with the amplitude approaching 1nT or above. The current results suggest that these nonlinear processes can cause significant deviation of transport coefficients from the prediction of QL theory, which should be taken into account in the future simulations of radiation belt dynamics driven by the EMIC waves.

  11. Effect of monochromatic light on circadian rhythmic expression of clock genes in the hypothalamus of chick.

    Science.gov (United States)

    Jiang, Nan; Wang, Zixu; Cao, Jing; Dong, Yulan; Chen, Yaoxing

    2017-08-01

    To clarify the effect of monochromatic light on circadian clock gene expression in chick hypothalamus, a total 240 newly hatched chickens were reared under blue light (BL), green light (GL), red light (RL) and white light (WL), respectively. On the post-hatched day 14, 24-h profiles of seven core clock genes (cClock, cBmal1, cBmal2, cCry1, cCry2, cPer2 and cPer3) were measured at six time points (CT 0, CT 4, CT 8, CT 12, CT 16, CT 20, circadian time). We found all these clock genes expressed with a significant rhythmicity in different light wavelength groups. Meanwhile, cClock and cBmal1 showed a high level under GL, and followed a corresponding high expression of cCry1. However, RL decreased the expression levels of these genes. Be consistent with the mRNA level, CLOCK and BMAL1 proteins also showed a high level under GL. The CLOCK-like immunoreactive neurons were observed not only in the SCN, but also in the non-SCN brain region such as the nucleus anterior medialis hypothalami, the periventricularis nucleus, the paraventricular nucleus and the median eminence. All these results are consistent with the auto-regulatory circadian feedback loop, and indicate that GL may play an important role on the circadian time generation and development in the chick hypothalamus. Our results also suggest that the circadian clock in the chick hypothalamus such as non-SCN brain region were involved in the regulation of photo information. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Human wavelength discrimination of monochromatic light explained by optimal wavelength decoding of light of unknown intensity.

    Directory of Open Access Journals (Sweden)

    Li Zhaoping

    Full Text Available We show that human ability to discriminate the wavelength of monochromatic light can be understood as maximum likelihood decoding of the cone absorptions, with a signal processing efficiency that is independent of the wavelength. This work is built on the framework of ideal observer analysis of visual discrimination used in many previous works. A distinctive aspect of our work is that we highlight a perceptual confound that observers should confuse a change in input light wavelength with a change in input intensity. Hence a simple ideal observer model which assumes that an observer has a full knowledge of input intensity should over-estimate human ability in discriminating wavelengths of two inputs of unequal intensity. This confound also makes it difficult to consistently measure human ability in wavelength discrimination by asking observers to distinguish two input colors while matching their brightness. We argue that the best experimental method for reliable measurement of discrimination thresholds is the one of Pokorny and Smith, in which observers only need to distinguish two inputs, regardless of whether they differ in hue or brightness. We mathematically formulate wavelength discrimination under this wavelength-intensity confound and show a good agreement between our theoretical prediction and the behavioral data. Our analysis explains why the discrimination threshold varies with the input wavelength, and shows how sensitively the threshold depends on the relative densities of the three types of cones in the retina (and in particular predict discriminations in dichromats. Our mathematical formulation and solution can be applied to general problems of sensory discrimination when there is a perceptual confound from other sensory feature dimensions.

  13. Melatonin modulates monochromatic light-induced melatonin receptor expression in the hypothalamus of chicks.

    Science.gov (United States)

    Zhang, Liwei; Chen, Funing; Cao, Jing; Dong, Yulan; Wang, Zixu; Chen, Yaoxing

    2017-09-01

    To study the mechanism of the effect of monochromatic light on physiological function in chicken, a total of 192 newly hatched chicks were randomly divided into intact, sham-operated and pinealectomy groups then exposed to white light (WL), red light (RL), green light (GL) and blue light (BL) using a light-emitting diode (LED) system for two weeks. At P14, the hypothalami were immediately collected for immunohistochemical staining of melatonin receptor subtypes (Mel1a and Mel1b) and detection of Mel1a and Mel1b expressions using RT-PCR and western blot. Immunohistochemical staining of the hypothalamus showed that the Mel1a-ir cells were distributed in the preoptic area (POA), nucleus preopticus periventricularis (POP) and suprachiasmatic nuclei (SCN), and the Mel1b-ir cells were presented in the POA and SCN. Analysis of RT-PCR and western blot showed that the mRNA and protein levels of Mel1a and Mel1b in the hypothalamus of chick exposed to GL were increased by 10.7-29.3%, 9.18-35.9% and 8.97-27.3% compared to those in the chicks exposed to WL (P=0.029-0.002), RL (P=0.027-0.001) and BL (P=0.038-0.007) in the intact group, respectively. After pinealectomy, however, these parameters decreased and there were no significant differences among the WL, RL, GL and BL groups. These findings suggested that melatonin plays a critical role in GL illumination-enhanced Mel1a and Mel1b expressions in the hypothalamus of chicks. Copyright © 2017 Elsevier GmbH. All rights reserved.

  14. The protection of operating personnel in nuclear power plants against the risk of nuclear incidents and ionizing radiation arising from normal operation of the plant. Rules and problems

    International Nuclear Information System (INIS)

    Ortore, F.; Scalera, D.

    1980-03-01

    After an analysis of the nuclear third party liability insurance policy to be taken out in Italy in implementation of Act no. 1860 of 31 December 1962 and Decree No. 519 of 10 May 1979, the collective policy against radiation injuries taken out for operating personnel in nuclear installations is described. The author is in favour of further harmonization of the legal system presently in force in this respect. (NEA) [fr

  15. Assessment of ionizing radiation as a risk factor for breast cancer incidence in Goiania; Avaliacao da radiacao ionizante como fator de risco para a incidencia de cancer de mama em Goiania

    Energy Technology Data Exchange (ETDEWEB)

    Lage, Leonardo Bastos

    2016-11-01

    This research aims to evaluate whether exposure to ionizing radiation to which women are subjected can be associated with the incidence of breast cancer in Goiania. The defined study area is the central region of Goiania, or the Sanitary Districts of Campinas-Centro and Sul, in which are the seven major accident sources of contamination with Cesium 137, and also, as shown by previous study, the majority of new cases of breast cancer (60,43 %). We used the geographical division of the city in census tracts and health districts. The data collection was divided in two stages: the first, for the survey of radiometric measurements, and the second, for identifying the addresses of women diagnosed with breast cancer. The radiometric survey occurred between 2010 and 2014, in which was used an environmental gamma radiation mobile measuring system. This system was composed by a high-sensitivity detector coupled to a Global Positioning System (GPS) and a microcomputer. The assembly was installed on a motor vehicle so that the height of the detector is found at one meter from the ground, and programmed to obtain a measurement of the doses absorbed in the air rate each second. The data collected were: doses absorbed in the air rate, geographical coordinates, altitude, date and time of acquisition. From Mobisys software, files were generated and from ArcGIS 10.0 platform, geospatial assessment survey through the elaboration of thematic maps and geospatial analysis statistics. The annual averages of effective doses and collective effective doses were estimated from the rate of doses absorbed in air collected by the system and the resident population in the census tracts. The second stage begun from the data collection at the Registry of Goiania's Population Based Cancer (RCBPGO), in which were identified addresses of women diagnosed with breast cancer between 2001 and 2010. Part of the data was geographically referenced and using census data were estimated and compared the

  16. Medical applications of synchrotron radiation

    International Nuclear Information System (INIS)

    Thomlinson, W.

    1991-10-01

    Ever since the first diagnostic x-ray was done in the United States on February 3, 1896, the application of ionizing radiation to the field of medicine has become increasingly important. Both in clinical medicine and basic research the use of x-rays for diagnostic imaging and radiotherapy is now widespread. Radiography, angiography, CAT and PETT scanning, mammography, and nuclear medicine are all examples of technologies developed to image the human anatomy. In therapeutic applications, both external and internal sources of radiation are applied to the battle against cancer. The development of dedicated synchrotron radiation sources has allowed exciting advances to take place in many of these applications. The new sources provide tunable, high-intensity monochromatic beams over a wide range of energies which can be tailored to specific programmatic needs. This paper surveys those areas of medical research in which synchrotron radiation facilities are actively involved

  17. Contact microscopy with synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Panessa-Warren, B.J.

    1985-10-01

    Soft x-ray contact microscopy with synchrotron radiation offers the biologist and especially the microscopist, a way to morphologically study specimens that could not be imaged by conventional TEM, STEM or SEM methods (i.e. hydrated samples, samples easily damaged by an electron beam, electron dense samples, thick specimens, unstained low contrast specimens) at spatial resolutions approaching those of the TEM, with the additional possibility to obtain compositional (elemental) information about the sample as well. Although flash x-ray sources offer faster exposure times, synchrotron radiation provides a highly collimated, intense radiation that can be tuned to select specific discrete ranges of x-ray wavelengths or specific individual wavelengths which optimize imaging or microanalysis of a specific sample. This paper presents an overview of the applications of x-ray contact microscopy to biological research and some current research results using monochromatic synchrotron radiation to image biological samples. 24 refs., 10 figs.

  18. Medical Applications of Synchrotron Radiation

    Science.gov (United States)

    Thomlinson, W.

    1991-10-01

    Ever since the first diagnostic x-ray was done in the United States on February 3, 1896, the application of ionizing radiation to the field of medicine has become increasingly important. Both in clinical medicine and basic research the use of x-rays for diagnostic imaging and radiotherapy is now widespread. Radiography, angiography, CAT and PETT scanning, mammography, and nuclear medicine are all examples of technologies developed to image the human anatomy. In therapeutic applications, both external and internal sources of radiation are applied to the battle against cancer. The development of dedicated synchrotron radiation sources has allowed exciting advances to take place in many of these applications. The new sources provide tunable, high-intensity monochromatic beams over a wide range of energies which can be tailored to specific programmatic needs. This paper surveys those areas of medical research in which synchrotron radiation facilities are actively involved.

  19. Radiation carcinogenesis

    International Nuclear Information System (INIS)

    Fry, R.J.M.

    1976-01-01

    The risk of iatrogenic tumors with radiation therapy is so outweighed by the benefit of cure that estimates of risk have not been considered necessary. However, with the introduction of chemotherapy, combined therapy, and particle radiation therapy, the comparative risks should be examined. In the case of radiation, total dose, fractionation, dose rate, dose distribution, and radiation quality should be considered in the estimation of risk. The biological factors that must be considered include incidence of tumors, latent period, degree of malignancy, and multiplicity of tumors. The risk of radiation induction of tumors is influenced by the genotype, sex, and age of the patient, the tissues that will be exposed, and previous therapy. With chemotherapy the number of cells at risk is usually markedly higher than with radiation therapy. Clearly the problem of the estimation of comparative risks is complex. This paper presents the current views on the comparative risks and the importance of the various factors that influence the estimation of risk

  20. Incidence and Predictive Factors of Pain Flare After Spine Stereotactic Body Radiation Therapy: Secondary Analysis of Phase 1/2 Trials

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Hubert Y.; Allen, Pamela K. [Department of Radiation Oncology, University of Texas MD Anderson Cancer, Houston, Texas (United States); Wang, Xin S. [Department of Symptom Research, University of Texas MD Anderson Cancer, Houston, Texas (United States); Chang, Eric L. [Department of Radiation Oncology, University of Texas MD Anderson Cancer, Houston, Texas (United States); Department of Radiation Oncology, USC Norris Cancer Center, Los Angeles, California (United States); Rhines, Laurence D.; Tatsui, Claudio E. [Department of Neurosurgery, University of Texas MD Anderson Cancer, Houston, Texas (United States); Amini, Behrang [Department of Diagnostic Radiology, University of Texas MD Anderson Cancer, Houston, Texas (United States); Wang, Xin A. [Department of Radiation Physics, University of Texas MD Anderson Cancer, Houston, Texas (United States); Tannir, Nizar M. [Department of Genitourinary Medical Oncology, University of Texas MD Anderson Cancer, Houston, Texas (United States); Brown, Paul D. [Department of Radiation Oncology, University of Texas MD Anderson Cancer, Houston, Texas (United States); Ghia, Amol J., E-mail: AJGhia@mdanderson.org [Department of Radiation Oncology, University of Texas MD Anderson Cancer, Houston, Texas (United States)

    2014-11-15

    Purpose/Objective(s): To perform a secondary analysis of institutional prospective spine stereotactic body radiation therapy (SBRT) trials to investigate posttreatment acute pain flare. Methods and Materials: Medical records for enrolled patients were reviewed. Study protocol included baseline and follow-up surveys with pain assessment by Brief Pain Inventory and documentation of pain medications. Patients were considered evaluable for pain flare if clinical note or follow-up survey was completed within 2 weeks of SBRT. Pain flare was defined as a clinical note indicating increased pain at the treated site or survey showing a 2-point increase in worst pain score, a 25% increase in analgesic intake, or the initiation of steroids. Binary logistic regression was used to determine predictive factors for pain flare occurrence. Results: Of the 210 enrolled patients, 195 (93%) were evaluable for pain flare, including 172 (88%) clinically, 135 (69%) by survey, and 112 (57%) by both methods. Of evaluable patients, 61 (31%) had undergone prior surgery, 57 (29%) had received prior radiation, and 34 (17%) took steroids during treatment, mostly for prior conditions. Pain flare was observed in 44 patients (23%). Median time to pain flare was 5 days (range, 0-20 days) after the start of treatment. On multivariate analysis, the only independent factor associated with pain flare was the number of treatment fractions (odds ratio = 0.66, P=.004). Age, sex, performance status, spine location, number of treated vertebrae, prior radiation, prior surgery, primary tumor histology, baseline pain score, and steroid use were not significant. Conclusions: Acute pain flare after spine SBRT is a relatively common event, for which patients should be counseled. Additional study is needed to determine whether prophylactic or symptomatic intervention is preferred.

  1. Incidence and Predictive Factors of Pain Flare After Spine Stereotactic Body Radiation Therapy: Secondary Analysis of Phase 1/2 Trials

    International Nuclear Information System (INIS)

    Pan, Hubert Y.; Allen, Pamela K.; Wang, Xin S.; Chang, Eric L.; Rhines, Laurence D.; Tatsui, Claudio E.; Amini, Behrang; Wang, Xin A.; Tannir, Nizar M.; Brown, Paul D.; Ghia, Amol J.

    2014-01-01

    Purpose/Objective(s): To perform a secondary analysis of institutional prospective spine stereotactic body radiation therapy (SBRT) trials to investigate posttreatment acute pain flare. Methods and Materials: Medical records for enrolled patients were reviewed. Study protocol included baseline and follow-up surveys with pain assessment by Brief Pain Inventory and documentation of pain medications. Patients were considered evaluable for pain flare if clinical note or follow-up survey was completed within 2 weeks of SBRT. Pain flare was defined as a clinical note indicating increased pain at the treated site or survey showing a 2-point increase in worst pain score, a 25% increase in analgesic intake, or the initiation of steroids. Binary logistic regression was used to determine predictive factors for pain flare occurrence. Results: Of the 210 enrolled patients, 195 (93%) were evaluable for pain flare, including 172 (88%) clinically, 135 (69%) by survey, and 112 (57%) by both methods. Of evaluable patients, 61 (31%) had undergone prior surgery, 57 (29%) had received prior radiation, and 34 (17%) took steroids during treatment, mostly for prior conditions. Pain flare was observed in 44 patients (23%). Median time to pain flare was 5 days (range, 0-20 days) after the start of treatment. On multivariate analysis, the only independent factor associated with pain flare was the number of treatment fractions (odds ratio = 0.66, P=.004). Age, sex, performance status, spine location, number of treated vertebrae, prior radiation, prior surgery, primary tumor histology, baseline pain score, and steroid use were not significant. Conclusions: Acute pain flare after spine SBRT is a relatively common event, for which patients should be counseled. Additional study is needed to determine whether prophylactic or symptomatic intervention is preferred

  2. Receiver-supported radiometry with cryoradiometers and monochromatized synchrotron radiation; Empfaengergestuetzte Radiometrie mit Kryoradiometern und monochromatisierter Synchrotronstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Gottwald, Alexander [Physikalisch-Technische Bundesanstalt (PTB), Berlin (Germany). Arbeitsgruppe ' UV- und VUV-Radiometrie' ; Kroth, Udo; Krumrey, Michael; Mueller, Peter; Scholze, Frank

    2014-09-15

    The cryoradiometers SYRES I and SYRES II used at the PTB are described. They consist of a cavity absorber and are operated at temperatures slightly above the boiling point of liquid helium. The calibration of the spectral sensitivity in the range from 3 eV to 100 keV is described. (HSI)

  3. Radiation stability of protein crystals grown by nanostructured templates: synchrotron microfocus analysis

    International Nuclear Information System (INIS)

    Pechkova, Eugenia; Tropiano, Giuseppe; Riekel, Christian; Nicolini, Claudio

    2004-01-01

    X-ray radiation damage of lysozyme single crystals by an intense monochromatic beam from a focussed third-generation synchrotron radiation source has been studied. The preliminary results show a significantly higher resistance to synchrotron radiation of lysozyme microcrystals produced by means of nanotechnology-based template with respect to those prepared by classical methodology. The implications of this finding for protein crystallography are discussed

  4. Risk of cancer incidence before the age of 15 years after exposure to ionising radiation from computed tomography: results from a German cohort study

    Energy Technology Data Exchange (ETDEWEB)

    Krille, L. [University Medical Center Mainz, Institute of Medical Biostatistics, Epidemiology and Informatics, Mainz (Germany); International Agency for Research on Cancer, Lyon (France); Dreger, S.; Zeeb, H. [University of Bremen, Leibniz - Institute for Prevention Research and Epidemiology - BIPS, Research Focus Health Sciences Bremen, Bremen (Germany); Schindel, R.; Blettner, M. [University Medical Center Mainz, Institute of Medical Biostatistics, Epidemiology and Informatics, Mainz (Germany); Albrecht, T. [Vivantes, Klinikum Neukoelln, Institut fuer Radiologie und Interventionelle Therapie, Berlin (Germany); Asmussen, M. [Zentralinstitut fuer Bildgebende Diagnostik, Staedtisches Klinikum Karlsruhe, Karlsruhe (Germany); Barkhausen, J. [Universitaetsklinikum Schleswig Holstein, Klinik fuer Radiologie und Nuklearmedizin, Campus Luebeck, Luebeck (Germany); Berthold, J.D. [Medizinische Hochschule Hannover, Institut fuer Diagnostische und Interventionelle Radiologie, Hannover (Germany); Chavan, A. [Klinikum Oldenburg GmbH, Institut fuer Diagnostische and Interventionelle Radiologie, Oldenburg (Germany); Claussen, C. [Universitaetsklinikum Tuebingen, Abt. fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Forsting, M. [Universitaetsklinikum Essen, Institut fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Essen (Germany); Gianicolo, E.A.L. [University Medical Center Mainz, Institute of Medical Biostatistics, Epidemiology and Informatics, Mainz (Germany); National Research Council, Institute of Clinical Physiology, Lecce (Italy); Jablonka, K. [Klinikum Bremen-Mitte, Klinik fuer Radiologische Diagnostik und Nuklearmedizin, Bremen (Germany); Jahnen, A. [Centre de Recherche Public Henri Tudor, Luxembourg (Luxembourg); Langer, M. [Universitaetsklinikum Freiburg, Klinik fuer Radiologie, Freiburg (Germany); Laniado, M. [Universitaetsklinikum Carl Gustav Carus Dresden, Institut und Poliklinik fuer Radiologische Diagnostik, Dresden (Germany); Lotz, J. [Universitaetsmedizin Goettingen, Institut fuer Diagnostische und Interventionelle Radiologie, Goettingen (Germany); Mentzel, H.J. [Universitaetsklinikum Jena, Institut fuer Diagnostische und Interventionelle Radiologie, Sektion Kinderradiologie, Jena (Germany); Queisser-Wahrendorf, A. [Universitaetsmedizin Mainz, Zentrum fuer Kinder- und Jugendmedizin, Mainz (Germany); Rompel, O. [Universitaetsklinikum Erlangen, Radiologisches Institut, Erlangen (Germany); Schlick, I. [Klinikum Nuernberg Sued, Institut fuer Radiologie und Neuroradiologie, Nuremberg (Germany); Schneider, K.; Seidenbusch, M. [Institut fuer Klinische Radiologie, Klinikum der Universitaet Muenchen, Dr. von Haunersches Kinderspital, Munich (Germany); Schumacher, M. [Universitaetsklinik Freiburg, Klinik fuer Neuroradiologie, Neurozentrum, Freiburg (Germany); Spix, C. [University Medical Center Mainz, German Childhood Cancer Registry, Mainz (Germany); Spors, B. [Charite - Universitaetsmedizin Berlin, Kinderradiologie, Standort Campus Virchow Klinikum, Berlin (Germany); Staatz, G. [Universitaetsmedizin Mainz, Klinik und Poliklinik fuer diagnostische und interventionelle Radiologie, Sektion Kinderradiologie, Mainz (Germany); Vogl, T. [Klinikum der Johann Wolfgang Goethe-Universitaet Frankfurt/Main, Institut fuer Diagnostische und Interventionelle Radiologie, Frankfurt (Germany); Wagner, J. [Vivantes, Klinikum im Friedrichshain, Institut fuer Radiologie und Interventionelle Therapie, Berlin (Germany); Weisser, G. [Universitaetsklinikum Mannheim, Institut fuer Klinische Radiologie und Nuklearmedizin, Mannheim (Germany)

    2015-03-15

    The aim of this cohort study was to assess the risk of developing cancer, specifically leukaemia, tumours of the central nervous system and lymphoma, before the age of 15 years in children previously exposed to computed tomography (CT) in Germany. Data for children with at least one CT between 1980 and 2010 were abstracted from 20 hospitals. Cancer cases occurring between 1980 and 2010 were identified by stochastic linkage with the German Childhood Cancer Registry (GCCR). For all cases and a sample of non-cases, radiology reports were reviewed to assess the underlying medical conditions at time of the CT. Cases were only included if diagnosis occurred at least 2 years after the first CT and no signs of cancer were recorded in the radiology reports. Standardised incidence ratios (SIR) using incidence rates from the general population were estimated. The cohort included information on 71,073 CT examinations in 44,584 children contributing 161,407 person-years at risk with 46 cases initially identified through linkage with the GCCR. Seven cases had to be excluded due to signs possibly suggestive of cancer at the time of first CT. Overall, more cancer cases were observed (O) than expected (E), but this was mainly driven by unexpected and possibly biased results for lymphomas. For leukaemia, the SIR (SIR = O/E) was 1.72 (95 % CI 0.89-3.01, O = 12), and for CNS tumours, the SIR was 1.35 (95 % CI 0.54-2.78, O = 7). Despite careful examination of the medical information, confounding by indication or reverse causation cannot be ruled out completely and may explain parts of the excess. Furthermore, the CT exposure may have been underestimated as only data from the participating clinics were available. This should be taken into account when interpreting risk estimates. (orig.)

  5. Generation of virtual monochromatic CBCT from dual kV/MV beam projections

    International Nuclear Information System (INIS)

    Li, Hao; Liu, Bo; Yin, Fang-Fang

    2013-01-01

    Purpose: To develop a novel on-board imaging technique which allows generation of virtual monochromatic (VM) cone-beam CT (CBCT) with a selected energy from combined kilovoltage (kV)/megavoltage (MV) beam projections. Methods: With the current orthogonal kV/MV imaging hardware equipped in modern linear accelerators, both MV projections (from gantry angle of 0°–100°) and kV projections (90°–200°) were acquired as gantry rotated a total of 110°. A selected range of overlap projections between 90° to 100° were then decomposed into two material projections using experimentally determined parameters from orthogonally stacked aluminum and acrylic step-wedges. Given attenuation coefficients of aluminum and acrylic at a predetermined energy, one set of VM projections could be synthesized from two corresponding sets of decomposed projections. Two linear functions were generated using projection information at overlap angles to convert kV and MV projections at nonoverlap angles to approximate VM projections for CBCT reconstruction. The contrast-to-noise ratios (CNRs) were calculated for different inserts in VM CBCTs of a CatPhan phantom with various selected energies and compared with those in kV and MV CBCTs. The effect of overlap projection number on CNR was evaluated. Additionally, the effect of beam orientation was studied by scanning the CatPhan sandwiched with two 5 cm solid-water phantoms on both lateral sides and an electronic density phantom with two metal bolt inserts. Results: Proper selection of VM energy [30 and 40 keV for low-density polyethylene (LDPE), polymethylpentene, 2 MeV for Delrin] provided comparable or even better CNR results as compared with kV or MV CBCT. An increased number of overlap kV and MV projection demonstrated only marginal improvements of CNR for different inserts (with the exception of LDPE) and therefore one projection overlap was found to be sufficient for the CatPhan study. It was also evident that the optimal CBCT image

  6. Low incidence of new biochemical and clinical hypogonadism following hypofractionated stereotactic body radiation therapy (SBRT monotherapy for low- to intermediate-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Pahira John

    2011-03-01

    Full Text Available Abstract Background The CyberKnife is an appealing delivery system for hypofractionated stereotactic body radiation therapy (SBRT because of its ability to deliver highly conformal radiation therapy to moving targets. This conformity is achieved via 100s of non-coplanar radiation beams, which could potentially increase transitory testicular irradiation and result in post-therapy hypogonadism. We report on our early experience with CyberKnife SBRT for low- to intermediate-risk prostate cancer patients and assess the rate of inducing biochemical and clinical hypogonadism. Methods Twenty-six patients were treated with hypofractionated SBRT to a dose of 36.25 Gy in 5 fractions. All patients had histologically confirmed low- to intermediate-risk prostate adenocarcinoma (clinical stage ≤ T2b, Gleason score ≤ 7, PSA ≤ 20 ng/ml. PSA and total testosterone levels were obtained pre-treatment, 1 month post-treatment and every 3 months thereafter, for 1 year. Biochemical hypogonadism was defined as a total serum testosterone level below 8 nmol/L. Urinary and gastrointestinal toxicity was assessed using Common Toxicity Criteria v3; quality of life was assessed using the American Urological Association Symptom Score, Sexual Health Inventory for Men and Expanded Prostate Cancer Index Composite questionnaires. Results All 26 patients completed the treatment with a median 15 months (range, 13-19 months follow-up. Median pre-treatment PSA was 5.75 ng/ml (range, 2.3-10.3 ng/ml, and a decrease to a median of 0.7 ng/ml (range, 0.2-1.8 ng/ml was observed by one year post-treatment. The median pre-treatment total serum testosterone level was 13.81 nmol/L (range, 5.55 - 39.87 nmol/L. Post-treatment testosterone levels slowly decreased with the median value at one year follow-up of 10.53 nmol/L, significantly lower than the pre-treatment value (p Conclusions Hypofractionated SBRT offers the radiobiological benefit of a large fraction size and is well-tolerated by

  7. Effect of an external alternating electric field non-monochromaticity on parametric excitation of surface ion cyclotron X-modes

    International Nuclear Information System (INIS)

    Girka, V O; Puzyrkov, S Yu; Shpagina, V O; Shpagina, L O

    2012-01-01

    The application of an external alternating electric field in the range of ion cyclotron frequencies is a well-known method for the excitation of surface electromagnetic waves. The present paper is devoted to the development of a kinetic theory of parametric excitation of these eigenwaves propagating across an external steady magnetic field along the plasma boundary at the second harmonic of the ion cyclotron frequency. Unlike previous papers on this subject, parametric excitation of surface ion cyclotron X-modes is studied here under the condition of non-monochromaticity of an external alternating electric field. Non-monochromaticity of the external alternating electric field is modeled by the superposition of two uniform and monochromatic electric fields with different amplitudes and frequencies. The nonlinear boundary condition is formulated for a tangential magnetic field of the studied surface waves. An infinite set of equations for the harmonics of a tangential electric field is solved using the approximation of the wave packet consisting of the main harmonic and two nearest satellite harmonics. Two different regimes of instability have been considered. If one of the applied generators has an operation frequency that is close to the ion cyclotron frequency, then changing the amplitude of the second generator allows one to enhance the growth rate of the parametric instability or to diminish it. But if the operation frequencies of the both generators are not close to the ion cyclotron frequency, then changing the amplitudes of their fields allows one to decrease the growth rate of the instability and even to suppress its development. The problem is studied both analytically and numerically.

  8. Recovery from Iridium-192 flakes of a radioactive source for industrial use after a radiation incident; Recuperacion de hojuelas de Iridio-192 provenientes de una fuente radiactivas de uso industrial despues de un incidente radiologico

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, W.H.; Zapata, L.A., E-mail: wcruz@ipen.gob.pe, E-mail: lzapata@ipen.gob.pe [Instituto Peruano de Energia Nuclear (GRRA/IPEN), Lima (Peru). Division de Gestion de Residuos Radiactivos

    2013-07-01

    The Iridium-192 ({sup 192}Ir) is the most used and ideal for industrial radiography applications, especially in petrochemical plants and pipelines and provides better contrast sensitivity for thick (25.4 mm). This source has constructive sealed double encapsulation, the internal capsule containing stainless steel to radioactive material in the form of flakes and welded with TIG process. The radiological incident happened at a gas station fuel sales in circumstances in which there was a homogeneity test welds a tank, the flakes or Ir-192 fell off his ponytail and left scattered over an area of 2 m{sup 2}, some fell flat areas and other land so collected in lead shielding and metal container and ground source. Full recovery of the leaflets was performed at the Division of radioactive waste management (GRRA) gaining a total of 22 flakes with no radiation risk to staff performance and installation and the conclusion was reached that the misapplicaion of TIG welding was the main cause the incident. (author)

  9. Nasopharyngeal carcinoma in a low incidence European area. A prospective observational analysis from the Head and Neck Study Group of the Italian Society of Radiation Oncology (AIRO)

    Energy Technology Data Exchange (ETDEWEB)

    Tonoli, S.; Bruschieri, L. [Brescia University, Istituto del Radio, Brescia (Italy); Alterio, D. [European Institute of Oncology, Milan (Italy); Caspiani, O. [Isola Tiberina Hospital, Rome (Italy); Bacigalupo, A. [IRCCS A.O.U. San Martino IST Genoa, Genoa (Italy); Bunkheila, F. [S. Orsola Hospital, Bologna (Italy); Cianciulli, M. [S. Camillo Hospital, Rome (Italy); Merlotti, A. [Busto Arsizio Hospital, Busto Arsizio (Italy); Podhradska, A. [Milan University - Monza S. Gerardo Hospital, Milan (Italy); Rampino, M. [Turin University, Turin (Italy); Cante, D. [Treviglio Hospital, Treviglio (Italy); Gatta, R. [Brescia University, Istituto del Radio, Brescia (Italy); Prato Hospital, Prato (Italy); Magrini, S.M.

    2016-12-15

    To evaluate the outcomes with respect to long-term survival and toxicity in patients with nasopharyngeal carcinoma (NPC) treated in a European country with low incidence. A prospective observational study carried out by the AIRO Head and Neck group in 12 Italian institutions included 136 consecutive patients treated with radiotherapy (RT) ± chemotherapy (CHT) for NPC (without distant metastasis) between January 1, 2008 and December 31, 2010. The disease-specific survival (DSS), overall survival (OS), and disease-free survival (DFS) at 5 years were 92 (±2), 91 (±3), and 69 % (±5 %), respectively. Distant failure was the most frequent modality of relapse. The local, regional, and locoregional control at 5 years were 89 (±3), 93 (±3), and 84 % (±4 %), respectively. The incidence of acute and late toxicity and the correlations with different clinical/technical variables were analyzed. Neoadjuvant CHT prolongs radiotherapy overall treatment time (OTT) and decreases treatment adherence during concomitant chemoradiotherapy. An adequate minimum dose coverage to PTV(T) is a predictive variable well related to outcome. Our data do not substantially differ in terms of survival and toxicity outcomes from those reported in larger series of patients treated in countries with higher incidences of NPC. The T stage (TNM 2002 UICC classification) is predictive of DSS and OS. The GTV volume (T ± N) and an adequate minimum PTV(T) coverage dose (D95 %) were also identified as potential predictive variables. Sophisticated technologies of dose delivery (IMRT) with image-guided radiotherapy could help to obtain better minimum PTV(T) coverage dose with increased DFS; distant metastasis after treatment still remains an unresolved issue. (orig.) [German] Bewertung von langfristigem Ueberleben und Toxizitaet bei Patienten mit Nasopharynxkarzinom (NPC), die in einem europaeischen Land mit geringer Inzidenz behandelt wurden. Die prospektive Beobachtungsanalyse, durchgefuehrt von der

  10. Note: Diagnosing femtosecond laser-solid interactions with monochromatic Kα imager and x-ray pinhole camera

    International Nuclear Information System (INIS)

    Lin, X. X.; Li, Y. T.; Liu, F.; Du, F.; Wang, S. J.; Chen, L. M.; Zhang, L.; Zheng, Y.; Liu, X.; Liu, X. L.; Wang, Z. H.; Ma, J. L.; Wei, Z. Y.; Liu, B. C.; Zhang, J.

    2011-01-01

    An x-ray pinhole camera and a monochromatic K α imager are used to measure the interactions of intense femtosecond laser pulses with Cu foil targets. The two diagnostics give different features in the spot size and the laser energy scaling, which are resulted from different physical processes. Under our experimental conditons, the K α emission is mainly excited by the fast electrons transporting inside the cold bulk target. In contrast, the x-ray pinhole signals are dominated by the broadband thermal x-ray emission from the hot plasma at the front target surface.

  11. Interim report of the DOE [Department of Energy] Type B Investigation Group: Appendix C, Oral statements about the RSI [Radiation Sterilizers, Inc.] incident

    International Nuclear Information System (INIS)

    Hultgren, R.O.

    1990-07-01

    Sometime between April 28, 1988, and June 5, 1988, a 22-inch long by 2.625-inch diameter doubly encapsulated cesium-137 irradiation source began leaking in the RSI-Decatur, Georgia, irradiation facility. By November 1988 when the source was isolated, between 7 and 8 curies (0.4 grams) leaked. This source was one of 1576 produced at Hanford to isolate the highly radioactive elements of wastes stored in single-walled tanks there. The capsule was designed for long term storage in a benign controlled pool environment on the Hanford reservation. An investigation was conducted to evaluate the cause of the incident, the management and administrative matters including leasing and licensing, the capsule design and manufacture, and the capsule qualification process. This Appendix presents transcripts of oral testimony taken during this investigation and is include as an integral part of the factual data upon which the Findings of this report are based. The transcriptions in every case were made available to the individuals involved for correction of factual misstatements and to be cleaned of verbal idiosyncrasies that detract from the meaning of the text

  12. Reference-free total reflection X-ray fluorescence analysis of semiconductor surfaces with synchrotron radiation.

    Science.gov (United States)

    Beckhoff, Burkhard; Fliegauf, Rolf; Kolbe, Michael; Müller, Matthias; Weser, Jan; Ulm, Gerhard

    2007-10-15

    Total reflection X-ray fluorescence (TXRF) analysis is a well-established method to monitor lowest level contamination on semiconductor surfaces. Even light elements on a wafer surface can be excited effectively when using high-flux synchrotron radiation in the soft X-ray range. To meet current industrial requirements in nondestructive semiconductor analysis, the Physikalisch-Technische Bundesanstalt (PTB) operates dedicated instrumentation for analyzing light element contamination on wafer pieces as well as on 200- and 300-mm silicon wafer surfaces. This instrumentation is also suited for grazing incidence X-ray fluorescence analysis and conventional energy-dispersive X-ray fluorescence analysis of buried and surface nanolayered structures, respectively. The most prominent features are a high-vacuum load-lock combined with an equipment front end module and a UHV irradiation chamber with an electrostatic chuck mounted on an eight-axis manipulator. Here, the entire surface of a 200- or a 300-mm wafer can be scanned by monochromatized radiation provided by the plane grating monochromator beamline for undulator radiation in the PTB laboratory at the electron storage ring BESSY II. This beamline provides high spectral purity and high photon flux in the range of 0.078-1.86 keV. In addition, absolutely calibrated photodiodes and Si(Li) detectors are used to monitor the exciting radiant power respectively the fluorescence radiation. Furthermore, the footprint of the excitation radiation at the wafer surface is well-known due to beam profile recordings by a CCD during special operation conditions at BESSY II that allow for drastically reduced electron beam currents. Thus, all the requirements of completely reference-free quantitation of TXRF analysis are fulfilled and are to be presented in the present work. The perspectives to arrange for reference-free quantitation using X-ray tube-based, table-top TXRF analysis are also addressed.

  13. Solar ultraviolet radiation incident upon reef snorkelers determined by consideration of the partial immersion of dosimeters in the natural ocean environment

    International Nuclear Information System (INIS)

    Downs, Nathan; Parisi, Alfio; Schouten, Peter

    2011-01-01

    Reef snorkelling is potentially a high-risk activity for persons visiting tropical and sub-tropical waters due to possible overexposure to solar ultraviolet radiation (UVR). Measurements and modelled estimates of the UVR received by human subjects are presented for a 10° latitudinal gradient of Australia's Great Barrier Reef and some Melanesian Islands (15°S to 25°S). A technique is described to measure the erythemally effective UVR received by the neck and the lower back. Measurements were made by application of a hybrid in-air and submerged calibration for polysulphone dosimeters. Measured exposures were used to model UVR exposure distributions at a number of popular snorkelling sites. A total of 11 snorkelling trials were held between 29 September 2009 and 26 January 2010. Exposures measured to the back and expressed relative to the horizontal plane ambient UVR have shown there to be some variation in the UVR distribution, with the neck receiving the greatest proportion of ambient UVR (0.56 ± 0.14 (1σ)), followed by the lower back (0.36 ± 0.14 (1σ)). Similarly high UVR exposures were determined at neck and lower back sites for different seasons, different times of day and over the latitudinal range of the study

  14. Effects of monochromatic light stimuli during embryogenesis on some performance traits, behavior, and fear responses in Japanese quails.

    Science.gov (United States)

    Sabuncuoglu, Kübra Melis; Korkmaz, Firdevs; Gürcan, Eser Kemal; Narinç, Dogan; Saml X, Hasan Ersin

    2018-04-14

    Lighting is crucial in poultry rearing and the subjects with light intensity, source, and color having been addressed in numerous studies. Numerous studies with monochromatic light from light-emitting diode (LED) bulbs have been reported. In the current study, fertile Japanese quail eggs were exposed to a dark environment (Control) or monochromatic green (560 nm) and blue (480 nm) lighting throughout incubation. There were no significant differences in hatch weight, hatchability, total embryonic mortality, hatch time, growth performance, and slaughter-carcass traits in the study (P > 0.05). Furthermore, the lowest mean in terms of early embryonic mortalities (12.37%) was determined in the group treated with green LED lighting (P < 0.05), whereas it was discovered that the lowest mean in terms of late embryonic mortalities (13.59%) was in the group treated with blue LED lighting (P < 0.05). During the test time, the green LED group showed higher averages in terms of the number of peeps and first defecation time as response to environmental stimuli (P < 0.05). The highest mean for jumping (7.6 times) was detected in the group treated with blue LED lighting (P < 0.05). In conclusion, it was revealed that the blue and green LED lighting applied to the Japanese quail eggs in incubation had no effects on incubation traits, growth, and slaughter-carcass traits but had positive effects on some behavioral traits.

  15. Analysis of gas exchange, stomatal behaviour and micronutrients uncovers dynamic response and adaptation of tomato plants to monochromatic light treatments.

    Science.gov (United States)

    O'Carrigan, Andrew; Babla, Mohammad; Wang, Feifei; Liu, Xiaohui; Mak, Michelle; Thomas, Richard; Bellotti, Bill; Chen, Zhong-Hua

    2014-09-01

    Light spectrum affects the yield and quality of greenhouse tomato, especially over a prolonged period of monochromatic light treatments. Physiological and chemical analysis was employed to investigate the influence of light spectral (blue, green and red) changes on growth, photosynthesis, stomatal behaviour, leaf pigment, and micronutrient levels. We found that plants are less affected under blue light treatment, which was evident by the maintenance of higher A, gs, Tr, and stomatal parameters and significantly lower VPD and Tleaf as compared to those plants grown in green and red light treatments. Green and red light treatments led to significantly larger increase in the accumulation of Fe, B, Zn, and Cu than blue light. Moreover, guard cell length, width, and volume all showed highly significant positive correlations to gs, Tr and negative links to VPD. There was negative impact of monochromatic lights-induced accumulation of Mn, Cu, and Zn on photosynthesis, leaf pigments and plant growth. Furthermore, most of the light-induced significant changes of the physiological traits were partially recovered at the end of experiment. A high degree of morphological and physiological plasticity to blue, green and red light treatments suggested that tomato plants may have developed mechanisms to adapt to the light treatments. Thus, understanding the optimization of light spectrum for photosynthesis and growth is one of the key components for greenhouse tomato production. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  16. The effect of pupil size on stimulation of the melanopsin containing retinal ganglion cells, as evaluated by monochromatic pupillometry

    DEFF Research Database (Denmark)

    Nissen, Claus Jeppe; Sander, Birgit; Lund-Andersen, Henrik

    2012-01-01

    or contracted, the entire sequence of red and blue light exposure repeated. After at least 3¿days, when the effect of the eye drop had subsided, the entire experiment was repeated, this time employing the other substance. Results: Prior dilatation of the left pupil augmented the post light contraction to blue...... (660¿nm) and in a following session, blue (470¿nm) light. The consensual pupillary diameter in the right eye was continuously measured before, during, and after light exposure. Subsequently, Tropicamide 1% or Pilocarpine 2% was instilled into the left eye and when the pupil was either maximally dilated......Purpose: To evaluate the influence of the size of the light exposed pupil in one eye on the pupillary light reflex of the other eye. Method: Using a monochromatic pupillometer, the left eye in each of 10 healthy subjects was exposed to 20¿s of monochromatic light of luminance 300¿cd/m(2), first red...

  17. Biological implications of radiation

    International Nuclear Information System (INIS)

    Bond, V.P.

    1977-01-01

    Some topics discussed are as follows: effects of diagnostic and therapeutic radiation on dividing cells, DNA, and blood cells; radiation sickness in relation to dose; early and late effects of radiation; effects of low dose irradiation; dose-effect curves; radioinduction of tumors in animals; and incidence of cancer in children following in utero exposure to diagnostic x rays

  18. Studies for the development of a micro-focus monochromatic x-ray source with making use of a highly charged heavy ion beam

    International Nuclear Information System (INIS)

    Nakamura, Nobuyuki; Yoshiyasu, Nobuo; Nakayama, Ryo; Watanabe, Hirofumi

    2008-01-01

    We propose a new scheme for a micro-focus monochromatic X-ray source using a focused highly charged ion beam colliding with a solid surface. When highly charged ion approaches a surface, many electrons are captured into the ion and the so-called hollow atom is produced. The hollow atom will decay by emitting X-rays before and after hitting the surface. Such X-rays do not contain any contribution from bremsstrahlung, so that monochromatic X-rays can be obtained by using proper filters. For the first step of realizing the proposed scheme, an ion focusing system with a glass capillary has been developed. In order to study the monochromaticity of the emission, X-ray spectra from hollow atoms produced in the collisions between highly charged heavy ions and several surfaces have been observed. (author)

  19. Decision analysis model evaluating the cost of a temporary hydrogel rectal spacer before prostate radiation therapy to reduce the incidence of rectal complications.

    Science.gov (United States)

    Hutchinson, Ryan C; Sundaram, Varun; Folkert, Michael; Lotan, Yair

    2016-07-01

    We conducted a decision analysis to evaluate the cost effectiveness of a newly Food and Drug Administration approved rectal spacer gel (SpaceOAR, Augmenix) for the reduction of rectal toxicity of prostate radiation therapy (RT). A decision tree model (TreeAge Pro) was used to compare the strategy of pretherapy placement of a spacing hydrogel before RT to RT alone. The model compared costs associated with rectal complications because of rectal toxicity over a 10-year period across 3 different RT modalities. Rectal toxicity rates were estimated from studies on conformal RT dose escalation, high-dose stereotactic body radiotherapy (SBRT) and low-dose SBRT. Rectal toxicity reduction rates (baseline reduction 70%) were estimated from recently published 15 month data using a rectal spacer. Direct and indirect cost estimates for established grades of rectal toxicity were based on national and institutional costs. Reduction in short-term complications were assumed to carry forward to a reduction in long-term toxicity. One-way and two-way sensitivity analyses were performed. The overall standard management cost for conformal RT was $3,428 vs. $3,946 with rectal spacer for an incremental cost of $518 over 10 years. A 1-way sensitivity analyses showed the breakeven cost of spacer at $2,332 or a breakeven overall risk reduction of 86% at a cost of $2,850. For high-dose SBRT, spacer was immediately cost effective with a savings of $2,640 and breakeven risk reduction at 36%. However, 2-way spacer cost to risk reduction sensitivity analyses were performed. The use of a rectal spacer for conformal RT results in a marginal cost increase with a significant reduction in rectal toxicity assuming recently published 15 month rectal toxicity reduction is maintained over 10 years. For high-dose SBRT it was cost effective. Further studies would be necessary to validate the long-term benefits of rectal spacers. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Theoretical study of the thermal radiation of rough surfaces. Development of a device for the measurement of emissivity, and application to AISI 316 stainless steel

    International Nuclear Information System (INIS)

    Heinisch, Bruno

    1982-01-01

    Within the frame of the study of heat transfers by radiation, this research thesis addresses the theoretical and experimental determination of the directional monochromatic emissivity. After some theoretical recalls, the author presents models for a direct calculation of emissivity, which in fact calculate bidirectional reflectivity by using laws of physical optics. An experimental device has been developed for the direct measurement of directional monochromatic emissivity of materials in the infrared (wavelength from 2 to 15 microns) in a polarised radiation. This device uses double beam with double modulation. Experimental results are presented for the 316 stainless steel [fr

  1. A phase-space beam position monitor for synchrotron radiation

    International Nuclear Information System (INIS)

    Samadi, Nazanin; Bassey, Bassey; Martinson, Mercedes; Belev, George; Dallin, Les; Jong, Mark de; Chapman, Dean

    2015-01-01

    A system has been developed to measure the vertical position and angle of the electron beam at a single location from a synchrotron source. The system uses a monochromator tuned to the absorption edge of a contrast material and has a sensitivity comparable with other beam position monitors. The stability of the photon beam position on synchrotron beamlines is critical for most if not all synchrotron radiation experiments. The position of the beam at the experiment or optical element location is set by the position and angle of the electron beam source as it traverses the magnetic field of the bend-magnet or insertion device. Thus an ideal photon beam monitor would be able to simultaneously measure the photon beam’s position and angle, and thus infer the electron beam’s position in phase space. X-ray diffraction is commonly used to prepare monochromatic beams on X-ray beamlines usually in the form of a double-crystal monochromator. Diffraction couples the photon wavelength or energy to the incident angle on the lattice planes within the crystal. The beam from such a monochromator will contain a spread of energies due to the vertical divergence of the photon beam from the source. This range of energies can easily cover the absorption edge of a filter element such as iodine at 33.17 keV. A vertical profile measurement of the photon beam footprint with and without the filter can be used to determine the vertical centroid position and angle of the photon beam. In the measurements described here an imaging detector is used to measure these vertical profiles with an iodine filter that horizontally covers part of the monochromatic beam. The goal was to investigate the use of a combined monochromator, filter and detector as a phase-space beam position monitor. The system was tested for sensitivity to position and angle under a number of synchrotron operating conditions, such as normal operations and special operating modes where the photon beam is intentionally altered

  2. Effect of monochromatic light on circadian rhythmic expression of clock genes and arylalkylamine N-acetyltransferase in chick retina.

    Science.gov (United States)

    Cao, Jing; Bian, Jiang; Wang, Zixu; Dong, Yulan; Chen, Yaoxing

    2017-01-01

    Birds have more developed visual function. They not only have the ability to detect light and darkness but also have the color vision. Previous study showed that monochromatic light influenced avian physiological processes, which were controlled by clock genes. Therefore, bird's eye is a good model to studying the impact of color of light on circadian rhythms. Avian retina is one of the most important central oscillations. The study was designed to investigate the effect of color of light on the expression of clock genes and arylalkylamine N-acetyltransferase (Aanat) mRNA expression in chick retina. A total of 240 post-hatching day (P) 0 broiler chickens were exposed to blue (BL), green (GL), red (RL) and white light (WL) from a LED system under a light-dark cycle 12L:12D for 14 d. The results show that the significant daily variations existed in the gene expression of cBmal1, cBmal2, cCry1, cCry2, cPer2 and cPer3, but not for cClock under four light treatments. The genes cBmal1, cCry1, cPer2 and cPer3 presented circadian rhythmic expression under the various monochromatic lights. When compared with WL, GL elevated the expression of positive regulators of cellular clock (cBmal1, cBmal2 and cClock) and cAanat mRNA level, whereas RL increased the mRNA levels of negative regulators of cellular clock (cCry1, cCry2, cPer2 and cPer3) and decreased the cAanat mRNA expression in the retina. These results demonstrated that monochromatic light affect the periodic expression levels of the biological clock mRNA by positive and negative feedback loop interactions, GL activated the transcription of cAanat; while RL suppressed the transcription of cAanat. Thereby, color of light regulates ocular cAanat expression by affecting on expression of cellular clock regulators.

  3. Preliminary design of a zone plate based hard X-ray monochromatic diffraction nanoprobe for materials studies at APS

    Science.gov (United States)

    Cai, Zhonghou; Liu, Wenjun; Tischler, Jonathan Z.; Shu, Deming; Xu, Ruqing; Schmidt, Oliver

    2013-09-01

    Aiming at studies of the micro/nano-structures of a broad range materials and electronic devices, Advance Photon Source (APS) is developing a dedicated diffraction nanoprobe (DNP) beamline for the needs arising from a multidiscipline research community. As a part of the APS Upgrade Project, the planed facility, named Sub-micron 3-D Diffraction (S3DD) beamline1, integrates the K-B mirror based polychromatic Laue diffraction and the Fresnel zone-plate based monochromatic diffraction techniques that currently support 3D/2D microdiffraction programs at the 34-ID-E and 2-ID-D of the APS, respectively. Both diffraction nanoprobes are designed to have a 50-nm or better special resolution. The zone-plate based monochromatic DNP has been preliminarily designed and will be constructed at the sector 34-ID. It uses an APS-3.0-cm period or APS-3.3-cm period undulator, a liquid-nitrogen cooled mirror as its first optics, and a water cooled small gap silicon double-crystal monochromator with an energy range of 5-30 keV. A set of zone plates have been designed to optimize for focusing efficiency and the working distance based on the attainable beamline length and the beam coherence. To ensure the nanoprobe performance, high stiffness and high precision flexure stage systems have been designed or demonstrated for optics mounting and sample scanning, and high precision temperature control of the experimental station will be implemented to reduce thermal instability. Designed nanoprobe beamline has a good management on thermal power loading on optical components and allows high degree of the preservation of beam brilliance for high focal flux and coherence. Integrated with variety of X-ray techniques, planed facility provides nano-XRD capability with the maximum reciprocal space accessibility and allows micro/nano-spectroscopy studies with K-edge electron binding energies of most elements down to Vanadium in the periodic table. We will discuss the preliminary design of the zone

  4. Nonlinear excitation of electron cyclotron waves by a monochromatic strong microwave: computer simulation analysis of the MINIX results

    International Nuclear Information System (INIS)

    Matsumoto, H.; Kimura, T.

    1986-01-01

    Triggered by the experimental results of the MINIX, a computer simulation study was initiated on the nonlinear excitation of electrostatic electron cyclotron waves by a monochromatic electromagnetic wave such as the transmitted microwave in the MINIX. The model used assumes that both of the excited waves and exciting (pumping) electromagnetic wave as well as the idler electromagnetic wave propagate in the direction perpendicular to the external magnetic field. The simulation code used for this study was the one-and-two-half dimensional electromagnetic particle code named KEMPO. The simulation result shows the high power electromagnetic wave produces both the backscattered electromagnetic wave and electrostatic electron cyclotron waves as a result of nonlinear parametric instability. Detailed nonlinear microphysics related to the wave excitation is discussed in terms of the nonlinear wave-wave couplings and associated ponderomotive force produced by the high power electromagnetic waves. 2 references, 4 figures

  5. Photon activated therapy (PAT using monochromatic Synchrotron x-rays and iron oxide nanoparticles in a mouse tumor model: feasibility study of PAT for the treatment of superficial malignancy

    Directory of Open Access Journals (Sweden)

    Choi Gi-Hwan

    2012-10-01

    Full Text Available Abstract Background X-rays are known to interact with metallic nanoparticles, producing photoelectric species as radiosensitizing effects, and have been exploited in vivo mainly with gold nanoparticles. The purpose of this study was to investigate the potential of sensitizing effect of iron oxide nanoparticles for photon activated therapy. Methods X-rays photon activated therapy (PAT was studied by treating CT26 tumor cells and CT26 tumor-bearing mice loaded with 13-nm diameter FeO NP, and irradiating them at 7.1 keV near the Fe K-edge using synchrotron x-rays radiation. Survival of cells was determined by MTT assay, and tumor regression assay was performed for in vivo model experiment. The results of PAT treated groups were compared with x-rays alone control groups. Results A more significant reduction in viability and damage was observed in the FeO NP-treated irradiated cells, compared to the radiation alone group (p Conclusions An iron oxide nanoparticle enhanced therapeutic effect with relatively low tissue concentration of iron and 10 Gy of monochromatic X-rays. Since 7.1 keV X-rays is attenuated very sharply in the tissue, FeO NP-PAT may have promise as a potent treatment option for superficial malignancies in the skin, like chest wall recurrence of breast cancer.

  6. Systematic error in the precision measurement of the mean wavelength of a nearly monochromatic neutron beam due to geometric errors

    Energy Technology Data Exchange (ETDEWEB)

    Coakley, K.J., E-mail: kevin.coakley@nist.go [National Institute of Standards and Technology, 325 Broadway, Boulder, CO 80305 (United States); Dewey, M.S. [National Institute of Standards and Technology, Gaithersburg, MD (United States); Yue, A.T. [University of Tennessee, Knoxville, TN (United States); Laptev, A.B. [Tulane University, New Orleans, LA (United States)

    2009-12-11

    Many experiments at neutron scattering facilities require nearly monochromatic neutron beams. In such experiments, one must accurately measure the mean wavelength of the beam. We seek to reduce the systematic uncertainty of this measurement to approximately 0.1%. This work is motivated mainly by an effort to improve the measurement of the neutron lifetime determined from data collected in a 2003 in-beam experiment performed at NIST. More specifically, we seek to reduce systematic uncertainty by calibrating the neutron detector used in this lifetime experiment. This calibration requires simultaneous measurement of the responses of both the neutron detector used in the lifetime experiment and an absolute black neutron detector to a highly collimated nearly monochromatic beam of cold neutrons, as well as a separate measurement of the mean wavelength of the neutron beam. The calibration uncertainty will depend on the uncertainty of the measured efficiency of the black neutron detector and the uncertainty of the measured mean wavelength. The mean wavelength of the beam is measured by Bragg diffracting the beam from a nearly perfect silicon analyzer crystal. Given the rocking curve data and knowledge of the directions of the rocking axis and the normal to the scattering planes in the silicon crystal, one determines the mean wavelength of the beam. In practice, the direction of the rocking axis and the normal to the silicon scattering planes are not known exactly. Based on Monte Carlo simulation studies, we quantify systematic uncertainties in the mean wavelength measurement due to these geometric errors. Both theoretical and empirical results are presented and compared.

  7. Systematic error in the precision measurement of the mean wavelength of a nearly monochromatic neutron beam due to geometric errors

    Science.gov (United States)

    Coakley, K. J.; Dewey, M. S.; Yue, A. T.; Laptev, A. B.

    2009-12-01

    Many experiments at neutron scattering facilities require nearly monochromatic neutron beams. In such experiments, one must accurately measure the mean wavelength of the beam. We seek to reduce the systematic uncertainty of this measurement to approximately 0.1%. This work is motivated mainly by an effort to improve the measurement of the neutron lifetime determined from data collected in a 2003 in-beam experiment performed at NIST. More specifically, we seek to reduce systematic uncertainty by calibrating the neutron detector used in this lifetime experiment. This calibration requires simultaneous measurement of the responses of both the neutron detector used in the lifetime experiment and an absolute black neutron detector to a highly collimated nearly monochromatic beam of cold neutrons, as well as a separate measurement of the mean wavelength of the neutron beam. The calibration uncertainty will depend on the uncertainty of the measured efficiency of the black neutron detector and the uncertainty of the measured mean wavelength. The mean wavelength of the beam is measured by Bragg diffracting the beam from a nearly perfect silicon analyzer crystal. Given the rocking curve data and knowledge of the directions of the rocking axis and the normal to the scattering planes in the silicon crystal, one determines the mean wavelength of the beam. In practice, the direction of the rocking axis and the normal to the silicon scattering planes are not known exactly. Based on Monte Carlo simulation studies, we quantify systematic uncertainties in the mean wavelength measurement due to these geometric errors. Both theoretical and empirical results are presented and compared.

  8. Sensitivity and specificity of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen and optic disc oedema: optic disc drusen and oedema.

    Science.gov (United States)

    Gili, Pablo; Flores-Rodríguez, Patricia; Yangüela, Julio; Orduña-Azcona, Javier; Martín-Ríos, María Dolores

    2013-03-01

    Evaluation of the efficacy of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen (ONHD) and optic disc oedema (ODE). Sixty-six patients with ONHD, 31 patients with ODE and 70 healthy subjects were studied. Colour and monochromatic fundus photography with different filters (green, red and autofluorescence) were performed. The results were analysed blindly by two observers. The sensitivity, specificity and interobserver agreement (k) of each test were assessed. Colour photography offers 65.5 % sensitivity and 100 % specificity for the diagnosis of ONHD. Monochromatic photography improves sensitivity and specificity and provides similar results: green filter (71.20 % sensitivity, 96.70 % specificity), red filter (80.30 % sensitivity, 96.80 % specificity), and autofluorescence technique (87.8 % sensitivity, 100 % specificity). The interobserver agreement was good with all techniques used: autofluorescence (k = 0.957), green filter (k = 0.897), red filter (k = 0.818) and colour (k = 0.809). Monochromatic fundus photography permits ONHD and ODE to be differentiated, with good sensitivity and very high specificity. The best results were obtained with autofluorescence and red filter study.

  9. Calibration of photographic dosemeters to evaluate the personal equivalent dose, Hp (10), irradiated by different radiation qualities and angles of incidence; Calibracao de dosimetros fotograficos para avaliar o equivalente de dose pessoal, Hp(10), irradiados por diferentes qualidades de radiacao e angulos de incidencia

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, Christiana; Antonio Filho, Joao, E-mail: chsantoro@gmail.com, E-mail: jaf@ufpe.br [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Santos, Marcus Aurelio P.; Goncalves Filho, Luiz Carlos, E-mail: masantos@cnen.gov.br, E-mail: l.filho@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, Pe (Brazil)

    2013-07-01

    To use radiation detectors, should periodically perform tests and calibrations on instruments in order to verify its good functionality. One way to ascertain the quality of the instrument is to conduct a study of the angular dependence of the response of the radiation detectors. The photographic dosimetry has been used widely to quantify the radiation doses and to estimate levels of doses received by workers involved with X-and gamma radiation. Photographic dosimeters are used because provide wide range of exposure and good accuracy. One of the sources of error have been introduced by different irradiation geometries between calibration and measurement in radiation fields used in x-ray and gamma ray sources, therefore, there is a need for an evaluation of the sensitivity of dosimeters with variation of the angle of the incident beam. In this study were tested 190 photographic dosemeters in the Metrology Laboratory of the Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE) using the phantom H{sub p} (10), where the dosimeters are evaluated on the basis of the new operational magnitude for individual monitoring, the equivalent personal dose, H{sub p} (10). Angular dependence of these radiation detectors was studied in X radiation fields (in the range of 45 keV energy to 164 keV) and gamma radiation ({sup 137}Cs-662 keV e {sup 60}Co - 1250 keV)

  10. [Skin cancer incidence in Zacatecas].

    Science.gov (United States)

    Pinedo-Vega, José Luis; Castañeda-López, Rosalba; Dávila-Rangel, J Ignacio; Mireles-García, Fernando; Ríos-Martínez, Carlos; López-Saucedo, Adrián

    2014-01-01

    Skin cancer is the most frequent cancer related to ultraviolet radiation. The aim was to estimate the incidence of skin cancer type, melanoma and non-melanoma in Zacatecas, Mexico. An epidemiological study was carried out during the period from 2008 to 2012. The data were obtained from the Instituto Mexicano del Seguro Social (IMSS), Instituto de Seguridad y Servicios Sociales de los Trabajadores del Estado (ISSSTE), Secretaría de Salud de Zacatecas (SSZ) and a private source, the Centro Médico Alameda. The incidence and the global prevalence were estimated. We studied 958 skin cancer cases, histopathologically confirmed. The cases were distributed as: 63.6 % basal cell carcinomas, 25.8 % squamous cell carcinomas, and 10.6 % melanoma. Significantly higher proportions were observed in women in the basal cell carcinomas (60.4 %) and squamous cell carcinomas (53.4 %). However, in the case of melanoma, the major proportion was observed in men (55.9 %). The more frequent skin cancer location was the face and for basal cell carcinoma was the nose (53 %); for squamous cell carcinomas were the lips (36 %), and for melanoma it was also the nose (40 %). The skin cancer incidence was estimated in 20 cases for each 100 000 inhabitants. Linear regression analysis showed that the skin cancer is increasing at an annual rate of 10.5 %. The anatomical location indicates that solar UV radiation is a risk factor, since the face is the zone with major exposure to solar radiation.

  11. Ionizing radiations

    International Nuclear Information System (INIS)

    2009-01-01

    After having recalled some fundamental notions and measurement units related to ionizing radiations, this document describes various aspects of natural and occupational exposures: exposure modes and sources, exposure levels, biological effects, health impacts. Then, it presents prevention principles aimed at, in an occupational context of use of radiation sources (nuclear industry excluded), reducing and managing these exposures: risk assessment, implementation of safety from the front end. Some practical cases illustrate the radiation protection approach. The legal and regulatory framework is presented: general notions, worker exposure, measures specific to some worker categories (pregnant and breast feeding women, young workers, temporary workers). A last part describes what is to be done in case of incident or accident (dissemination of radioactive substances from unsealed sources, anomaly occurring when using a generator or a sealed source, post-accident situation)

  12. Radiofrequency radiation

    International Nuclear Information System (INIS)

    Elder, J.A.; Czerski, P.A.; Stuchly, M.A.; Mild, K.H.; Sheppard, A.R.

    1989-01-01

    High-level radiofrequency radiation is a source of thermal energy that carries all of the known implications of heating for biological systems, including burns, temporary and permanent changes in reproduction, cataracts, and death. In general, no changes in chromosomes, DNA or the reproductive potential of animals exposed to RF radiation have been reported in the absence of significant rises in temperature, though there are limited data on DNA and chromosomal changes at non-thermal levels. Human data are currently limited and do not provide adequate information about the relationship between prolonged low-level RF radiation exposure and increased mortality or morbidity, including cancer incidence. In epidemiological studies and clinical reports of RF effects in man, the problems of quantification are numerous and include uncertainties about ''dose'', health effects, latent periods, dose-response relationships, and interactions with other physical or chemical agents. 228 refs, 6 figs, 2 tabs

  13. Predictive markers of radiation pneumonitis.

    Science.gov (United States)

    Provatopoulou, X; Athanasiou, E; Gounaris, A

    2008-01-01

    Radiation pneumonitis is an acute-phase response to radiation therapy and a common complication that affects a patient's quality of life. Under the need to reduce the incidence and severity of radiation-induced pulmonary complications as well as to identify patients at risk, several investigations on potential predictive markers of radiation pneumonitis have been conducted. The present study reviews the currently available knowledge on biomolecules of potential predictive value for radiation pneumonitis.

  14. Indoor ionizing radiation

    International Nuclear Information System (INIS)

    Ericson, S.O.; Lindvall, T.; Maansson, L-G.

    1986-01-01

    Radiation in indoor air is discussed in the perspective of the effective dose equivalents from other sources of radiation. Estimates of effective doses equivalents from indoor radon and its contribution to lung cancer incidence are reviewed. Swedish experiences with cost effective remedial actions are presented. The authors present optimal strategies for screening measurements and remedial actions in cost-benefit perspective. (author.)

  15. Online analysis of sulfur in diesel line by a monochromatic wavelength dispersive x-ray fluorescence spectrometry

    Science.gov (United States)

    Pérez-Careta, Eduardo; López-Ramírez, Juan Antonio; Reynoso-Whitaker, Gilberto; Sánchez-Mondragon, Javier; Torres-Cisneros, Miguel

    2009-09-01

    This paper proposes the application of a monochromatic wavelength dispersive X-ray fluorescence (MWDXRF) technique developed in the X-ray Optical Systems laboratory Inc. The technique measures low-level sulfur (uls) in fuel. Data for ultra low sulfur in diesel were collected and analyzed using the combination of the mentioned technique and the usage of engineering tools as a fastloop array and a measurement technique. This provides a qualitative method for Diesel sulfur analysis of the Refinery Ing. Antonio M Amor (RIAMA) in Salamanca, Guanajuato. The pooled limit of quantification (PLOQ) for ultra-low-sulfur diesel was found to be less than 1.5 ppm in this study. The reproducibility of 15-ppm sulfur diesel fuel was determined to be better than 3 ppm (95 % confident level). This work shows the performance of the production of Diesel with less than 15-ppm in sulfur lines in the Hydrodesulfurizer Unit of Diesel (HDD) of the refinery. Results and conclusions discusses the better and cheaper method for the production of ultra low sulfur Diesel in the refinery.

  16. Comparison of Ocular Monochromatic Higher-order Aberrations in Normal Refractive Surgery Candidates of Arab and South Asian Origin.

    Science.gov (United States)

    Prakash, Gaurav; Srivastava, Dhruv; Choudhuri, Sounak; Bacero, Ruthchel

    2016-01-01

    To compare the ocular monochromatic higher-order aberration. (HOA) profile in normal refractive surgery candidates of Arab and South Asian origin. This cross-sectional, observational, comparative study was performed in the cornea department of a specialty hospital. Normal refractive surgery candidates with no ocular morbidity except refractive error were recruited. Refractive surgery candidates underwent a preoperative evaluation, including wavefront aberrometry with the iDesign aberrometer (AMO, Inc., Santa Ana, California, United States). The HOA from right eyes were analyzed for HOA signed, absolute, and polar Zernike coefficients. Two hundred Arab participants (group 1) and 200 participants of South-Asian origin (group 2) comprised the study sample. The age and refractive status were comparable between groups. The mean of the HOA root mean square (RMS) was 0.36 ± 17 μ and 0.38 ± 18 μ for Arab and South-Asian eyes, respectively (P 0.002 [0.05/22]). The polar coefficients for coma, trefoil, spherical aberration, and tetrafoil were comparable between groups (P > 0.05, RST). Combined RMS values of third, fourth, fifth, and sixth order also were comparable between groups (P > 0.05, RST). Preoperative whole eye HOA were similar for refractive surgery candidates of Arab and South-Asian origin. The values were comparable to historical data for Caucasian eyes and were lower than Asian (Chinese) eyes. These findings may aid in refining refractive nomograms for wavefront ablations.

  17. Application of FEL technique for constructing high-intensity, monochromatic, polarized gamma-sources at storage rings

    Energy Technology Data Exchange (ETDEWEB)

    Saldin, E.L.; Schneidmiller, E.A.; Ulyanov, Yu.N. [Automatic Systems Corporation, Samara (Russian Federation)] [and others

    1995-12-31

    A possibility to construct high-intensity tunable monochromatic{gamma}-source at high energy storage rings is discussed. It is proposed to produce {gamma}-quanta by means of Compton backscattering of laser photons on electrons circulating in the storage. The laser light wavelength is chosen in such a way that after the scattering, the electron does not leave the separatrix. So as the probability of the scattering is rather small, energy oscillations are damped prior the next scattering. As a result, the proposed source can operate in {open_quotes}parasitic{close_quote} mode not interfering with the main mode of the storage ring operation. Analysis of parameters of existent storage rings (PETRA, ESRF, Spring-8, etc) shows that the laser light wavelength should be in infrared, {lambda}{approximately} 10 - 400 {mu}m, wavelength band. Installation at storage rings of tunable free-electron lasers with the peak and average output power {approximately} 10 MW and {approximately} 1 kW, respectively, will result in the intensity of the {gamma}-source up to {approximately} 10{sup 14}s{sup -1} with tunable {gamma}-quanta energy from several MeV up to several hundreds MeV. Such a {gamma}-source will reveal unique possibilities for precision investigations in nuclear physics.

  18. The Effect of Monochromatic Infrared Photo Energy on the Irritability of Myofascial Trigger Spot of Rabbit Skeletal Muscle

    Directory of Open Access Journals (Sweden)

    Ta-Shen Kuan

    2015-01-01

    Full Text Available Objective. To determine whether the vasodilatation effect of monochromatic infrared photo energy (MIRE had the potential for the treatment of myofascial trigger spot (MTrS in rabbits. Design. A randomized-controlled animal study. Subjects. Twelve adult New Zealand rabbits. Methods. For each rabbit, a MTrS (equivalent to a myofascial trigger point in humans in one side of the biceps femoris muscle was randomly selected for MIRE treatment (experimental side, while another MTrS in the other side (control side received a sham treatment. The intervention consisted of a daily 40 minutes treatment, three times per week for 2 weeks. The prevalence of endplate noise (EPN loci in the MTrS was assessed before, immediately after, and one week after the completion of the 2-week treatment. Results. MIRE could suppress the prevalence of EPN in the MTrS. The degree of reduction in EPN prevalence in the MTrS between the experimental side and the control side was significantly different immediately after MIRE treatment, but not significantly different one week after MIRE treatment. Conclusion. Our study suggests that MIRE may be a useful therapeutic option for the management of the myofascial trigger point in humans.

  19. Dual energy computed tomography quantification of carotid plaques calcification: comparison between monochromatic and polychromatic energies with pathology correlation

    Energy Technology Data Exchange (ETDEWEB)

    Mannelli, Lorenzo [University of Washington, Departments of Radiology, Seattle, WA (United States); Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY (United States); MacDonald, Lawrence; Ferguson, Marina; Shuman, William P.; Xu, Dongxiang; Yuan, Chun; Mitsumori, Lee M. [University of Washington, Departments of Radiology, Seattle, WA (United States); Mancini, Marcello; Ragucci, Monica; Monti, Serena [IRCCS Fondazione SDN, Naples (Italy)

    2015-05-01

    We compared carotid plaque calcification detection sensitivity and apparent cross-sectional area on CT as a function of CT beam energy using conventional CT techniques and virtual mono-energetic CT images generated from dual-energy acquisitions. Five ex-vivo carotid endarterectomy (CEA) specimens were imaged with dual-energy computed tomography. Virtual monochromatic spectrum (VMS) CT images were reconstructed at energies between 40-140 keV. The same specimens were imaged using conventional polyenergetic spectrum (PS) CT with peak beam energies 80, 100, 120, and 140 kVp. The histological calcium areas on each corresponding CEA specimen were traced manually on digitized images of Toluidine-Blue/Basic-Fuchsin stained plastic sections. 40 keV VMS CT images provided high detection sensitivity (97 %) similar to conventional PS CT images (∝96 %). The calcification size measured on CT decreased systematically with increasing CT beam energy; the rate of change was larger for the VMS images than for PS images. From a single dual-energy CT, multiple VMS-CT images can be generated, yielding equivalent detection sensitivity and size correlations as conventional PS-CT in CEA calcification imaging. VMS-CT at 80-100 keV provided the most accurate estimates of calcification size, as compared to histology, but detection sensitivity was reduced for smaller calcifications on these images. (orig.)

  20. Effects of White Leds on Growth and Phytonutrients of Outredgeous Romaine Lettuce When Supplemented with Various Monochromatic Wavelengths

    Science.gov (United States)

    Mickens, Matthew; Skoog, Emilie J.; Barnwell, Payton; Massa, Gioia; Wheeler, Raymond

    2017-01-01

    Growing plants in space will be an essential part of sustaining astronauts during long-range missions. To drive photosynthesis, light-emitting diodes (LEDs) are becoming superior because of their efficiency, longevity, small size, safety, and wavelength versatility. Isolating the effects of certain wavelengths on plant growth when combined with white light is attracting attention. To optimize crop production/quality in space, this study has aimed to configure novel light recipes for the Advanced Plant Habitat currently aboard the International Space Station (ISS). By using white light as a background to maintain normal growth, the addition of monochromatic wavelengths provides a clearer understanding of how each part of the visible spectrum affects plant growth. By growing Outredgeous lettuce under six treatments of White (W) LEDs, W + blue (B), W+ green (G), W + red (R), W + far red (FR), and RGB + FR LEDs with ratios similar to natural sunlight, this investigation has assessed differences in biomass, morphology, chlorophyll, and the synthesis of key phytonutrients. The potential for Outredgeous to produce anthocyanin, lutein, potassium, magnesium, and iron is paramount to maintaining astronaut health. The crop responses to each treatment have been evaluated and the optimal LED combination for both plant yield and nutrient content will be presented.

  1. Development of quasi-monochromatic p-7Li neutron generating system for 80-210 MeV

    International Nuclear Information System (INIS)

    Nakao, Noriaki; Shibata, Tokushi; Nakamura, Takashi; Uwamino, Yoshitomo; Nakanishi, Noriyoshi; Kurosawa, Tadahiro; Kim, Unju.

    1996-01-01

    Recently the requirements for the experimental data on the response characteristics of neutron detector and the cross section for neutron generation by charged particles have been increasing for shield designing. Here, a system for quasi-monochromatic neutron generation was developed in the facility of ring-cyclotron in Institute of Physical and Chemical Sciences. In this study, H 2 + accelerated to an energy range of 80-135 MeV/n and P + to 150-210 MeV was irradiated to E4 beam course and NE102A plastic scintillator was used for monitoring the neutron flux. The amount of neutrons generated was estimated from the radioactivity of 7 Be produced in 7 Li-target. The neutron spectres thus estimated as an energy range of 80-210 MeV were presented and the lower limit of these spectres was about 20 MeV. The peaks in the range of 150 and 210 MeV were comparatively wide because of the inferiority of energy resolving power at a higher energy level. (M.N.)

  2. Study and production of polarized monochromatic thermal neutron beams; Etude et production de faisceaux monochromatiques polarises de neutrons lents

    Energy Technology Data Exchange (ETDEWEB)

    Beiln, H. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-06-15

    Results obtained with a recently built neutron spectrometer producing monochromatic polarized neutron beams,in the energy rang (10{sup -3} - 10) eV and using a series of artificial (Co: 92 per cent - Fe: 8 per cent) monocrystal as polarizers and analysers, are given. A high precision method for cutting monocrystals is explained. A description of the installation itself as well as some results obtained with Fe{sub 3}O{sub 4} crystals are also given. Experimental result pertaining to various magnetic guide and 'spin flip' system, as required in the handling of such polarized neutron beams, are also discussed. (author) [French] Nous donnons les resultats obtenus avec un spectrometre produisant des neutrons monochromatiques polarises d'energie comprise entre quelques milliemes d'electronvolts et quelques electronvotts qui utilise une serie de monocristaux artificiels de Co: 92 pour cent - Fe: 8 pour cent, comme polariseurs et analyseurs. Nous discutons egalement une methode de taille de monocristaux a tres haute precision. Le dispositif experimental ainsi que quelques resultats preliminaires obtenus avec des monocristaux de Fe{sub 3}O{sub 4} sont egalement donnes. Nous discutons egalement des resultats experimentaux obtenus avec differents systemes de guidage magnetique et de renversement du spin. (auteur)

  3. Goiania incident case study

    International Nuclear Information System (INIS)

    Petterson, J.S.

    1988-06-01

    The reasons for wanting to document this case study and present the findings are simple. According to USDOE technical risk assessments (and our own initial work on the Hanford socioeconomic study), the likelihood of a major accident involving exposure to radioactive materials in the process of site characterization, construction, operation, and closure of a high-level waste repository is extremely remote. Most would agree, however, that there is a relatively high probability that a minor accident involving radiological contamination will occur sometime during the lifetime of the repository -- for example, during transport, at an MRS site or at the permanent site itself during repacking and deposition. Thus, one of the major concerns of the Yucca Mountain Socioeconomic Study is the potential impact of a relatively minor radiation-related accident. A large number of potential impact of a relatively minor radiation-related accident. A large number of potential accident scenarios have been under consideration (such as a transportation or other surface accident which results in a significant decline in tourism, the number of conventions, or the selection of Nevada as a retirement residence). The results of the work in Goiania make it clear, however, that such a significant shift in established social patterns and trends is not likely to occur as a direct outcome of a single nuclear-related accident (even, perhaps, a relatively major one), but rather, are likely to occur as a result of the enduring social interpretations of such an accident -- that is, as a result of the process of understanding, communicating, and socially sustaining a particular set of associations with respect to the initial incident

  4. Investigating phase behavior and structural changes in NiO/Ni-YSZ composite with monochromatic in-situ 2D and static 3D neutron imaging

    DEFF Research Database (Denmark)

    Makowska, Malgorzata G.; Strobl, Markus; Kardjilov, Nikolay

    2017-01-01

    In this work, we report neutron imaging studies of redox cycling of NiO/Ni-8YSZ (nickel/nickel oxide – yttria stabilized zirconia) composite used for electrodes in solid oxide electrochemical cells for efficient energy conversion (power-to-gas and vice versa) purposes (i.e. for anodes in solid...... source SINQ of Paul Scherrer Institut (PSI, Switzerland) by means of monochromatic neutron imaging, and post mortem monochromatic neutron tomography was performed at Helmholtz Zentrum Berlin (HZB) at the BER II reactor using the CONRAD-2 imaging instrument. Combining both time resolved radiography...... oxide fuel cells, and for cathodes in solid oxide electrolysis cells). Results of in-situ 2D and ex-situ 3D measurements are presented. In-situ observation of phase transition between NiO and Ni were performed at the test Beamline for neutron Optics and other Applications (BOA) at the continuous neutron...

  5. Accuracy of Dual-Energy Virtual Monochromatic CT Numbers: Comparison between the Single-Source Projection-Based and Dual-Source Image-Based Methods.

    Science.gov (United States)

    Ueguchi, Takashi; Ogihara, Ryota; Yamada, Sachiko

    2018-03-21

    To investigate the accuracy of dual-energy virtual monochromatic computed tomography (CT) numbers obtained by two typical hardware and software implementations: the single-source projection-based method and the dual-source image-based method. A phantom with different tissue equivalent inserts was scanned with both single-source and dual-source scanners. A fast kVp-switching feature was used on the single-source scanner, whereas a tin filter was used on the dual-source scanner. Virtual monochromatic CT images of the phantom at energy levels of 60, 100, and 140 keV were obtained by both projection-based (on the single-source scanner) and image-based (on the dual-source scanner) methods. The accuracy of virtual monochromatic CT numbers for all inserts was assessed by comparing measured values to their corresponding true values. Linear regression analysis was performed to evaluate the dependency of measured CT numbers on tissue attenuation, method, and their interaction. Root mean square values of systematic error over all inserts at 60, 100, and 140 keV were approximately 53, 21, and 29 Hounsfield unit (HU) with the single-source projection-based method, and 46, 7, and 6 HU with the dual-source image-based method, respectively. Linear regression analysis revealed that the interaction between the attenuation and the method had a statistically significant effect on the measured CT numbers at 100 and 140 keV. There were attenuation-, method-, and energy level-dependent systematic errors in the measured virtual monochromatic CT numbers. CT number reproducibility was comparable between the two scanners, and CT numbers had better accuracy with the dual-source image-based method at 100 and 140 keV. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  6. Feasibility and accuracy of relative electron density determined by virtual monochromatic CT value subtraction at two different energies using the gemstone spectral imaging

    International Nuclear Information System (INIS)

    Ogata, Toshiyuki; Ogawa, Kazuhiko; Koizumi, Masahiko; Ueguchi, Takashi; Yagi, Masashi; Yamada, Sachiko; Tanaka, Chikako; Ogihara, Ryota; Isohashi, Fumiaki; Yoshioka, Yasuo; Tomiyama, Noriyuki

    2013-01-01

    Recent work by Saito (2012) has demonstrated a simple conversion from energy-subtracted computed tomography (CT) values (ΔHU) obtained using dual-energy CT to relative electron density (RED) via a single linear relationship. The purpose of this study was to investigate the feasibility of this method to obtain RED from virtual monochromatic CT images obtained by the gemstone spectral imaging (GSI) mode with fast-kVp switching. A tissue characterization phantom with 13 inserts made of different materials was scanned using the GSI mode on a Discovery CT750 HD. Four sets of virtual monochromatic CT images (60, 77, 100 and 140 keV) were obtained from a single GSI acquisition. When we define Δ HU in terms of the weighting factor for the subtraction α, Δ HU ≡ (1 + α)H - αL (H and L represent the CT values for high and low energy respectively), the relationship between Δ HU and RED is approximated as a linear function, a × Δ HU/1000 + b (a, b = unity). We evaluated the agreement between the determined and nominal RED. We also have investigated reproducibility over short and long time periods. For the 13 insert materials, the RED determined by monochromatic CT images agreed with the nominal values within 1.1% and the coefficient of determination for this calculation formula was greater than 0.999. The observed reproducibility (1 standard deviation) of calculation error was within 0.5% for all materials. These findings indicate that virtual monochromatic CT scans at two different energies using GSI mode can provide an accurate method for estimating RED

  7. Committee on Medical Aspects of Radiation in the Environment (COMARE) 4. report. The incidence of cancer and leukaemia in young people in the vicinity of the Sellafield site, West Cumbria: Further studies and an update of the situation since the publication of the report of the Black Advisory Group in 1984

    International Nuclear Information System (INIS)

    Bridges, B.A.

    1996-01-01

    The Fourth Report of the Committee on Medical Aspects of Radiation in the Environment (COMARE) updates the information on the incidence of cancer and leukaemia in young people in the vicinity of the Sellafield site since the publication of the Black Advisory Group report in 1984. Data are reviewed on radiation exposure and the risk of radiation-induced leukaemia and cancer in young people living in Seascale; possible effects of paternal preconception irradiation in cancer; exposure to chemicals used at and discharged from the Sellafield site and the risk to the general population and offspring of site workers; and the infectious aetiology of childhood cancer. The history of the Royal Ordnance Factories sited at Sellafield and Drigg in the 1940s and a historical review of childhood cancer in Seascale is also given. (UK)

  8. Long-term Results of Carbon Ion Radiation Therapy for Locally Advanced or Unfavorably Located Choroidal Melanoma: Usefulness of CT-based 2-Port Orthogonal Therapy for Reducing the Incidence of Neovascular Glaucoma

    Energy Technology Data Exchange (ETDEWEB)

    Toyama, Shingo [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Department of Heavy Particle Therapy and Radiation Oncology, Faculty of Medicine, Saga University, Saga (Japan); Tsuji, Hiroshi, E-mail: h_tsuji@nirs.go.jp [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Mizoguchi, Nobutaka; Nomiya, Takuma; Kamada, Tadashi [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Tokumaru, Sunao [Department of Heavy Particle Therapy and Radiation Oncology, Faculty of Medicine, Saga University, Saga (Japan); Mizota, Atsushi [Department of Ophthalmology, Teikyo University School of Medicine, Tokyo (Japan); Ohnishi, Yoshitaka [Department of Ophthalmology, Wakayama Medical University, Wakayama (Japan); Tsujii, Hirohiko [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan)

    2013-06-01

    Purpose: To determine the long-term results of carbon ion radiation therapy (C-ion RT) in patients with choroidal melanoma, and to assess the usefulness of CT-based 2-port irradiation in reducing the risk of neovascular glaucoma (NVG). Methods and Materials: Between January 2001 and February 2012, a total of 116 patients with locally advanced or unfavorably located choroidal melanoma received CT-based C-ion RT. Of these patients, 114 were followed up for more than 6 months and their data analyzed. The numbers of T3 and T2 patients (International Union Against Cancer [UICC], 5th edition) were 106 and 8, respectively. The total dose of C-ion RT varied from 60 to 85 GyE, with each dose given in 5 fractions. Since October 2005, 2-port therapy (51 patients) has been used in an attempt to reduce the risk of NVG. A dose-volume histogram analysis was also performed in 106 patients. Results: The median follow-up was 4.6 years (range, 0.5-10.6 years). The 5-year overall survival, cause-specific survival, local control, distant metastasis-free survival, and eye retention rates were 80.4% (95% confidence interval 89.0%-71.8%), 82.2% (90.6%-73.8%), 92.8% (98.5%-87.1%), 72.1% (81.9%-62.3%), and 92.8% (98.1%-87.5%), respectively. The overall 5-year NVG incidence rate was 35.9% (25.9%-45.9%) and that of 1-port group and 2-port group were 41.6% (29.3%-54.0%) and 13.9% (3.2%-24.6%) with statistically significant difference (P<.001). The dose-volume histogram analysis showed that the average irradiated volume of the iris-ciliary body was significantly lower in the non-NVG group than in the NVG group at all dose levels, and significantly lower in the 2-port group than in the 1-port group at high dose levels. Conclusions: The long-term results of C-ion RT for choroidal melanoma are satisfactory. CT-based 2-port C-ion RT can be used to reduce the high-dose irradiated volume of the iris-ciliary body and the resulting risk of NVG.

  9. Medical application of Synchrotron Radiation

    International Nuclear Information System (INIS)

    Hyodo, Kazuyuki; Nishimura, Katsuyuki.

    1990-01-01

    The number of patients suffering from ischemic heart disease is also increasing rapidly in Japan. The standard method for assessing coronary artery diseases is the coronary angiography. Excellent images are taken by this method, however, it is an invasive method in which a catheter into a peripheral artery. The patients would obtain great benefit if the coronary arteries could be distinguished by intravenous injection of the contrast material. The K-edge subtraction method, which uses the K-edge discontinuity in the attenuation coefficient of the contrast material, is considered to be the most suitable method for coronary angiography by peripheral venous injection. Synchrotron Radiation (SR) is so intense that it allows selection of monochromatic X-rays, and studies on K-edge subtraction using SR has been started at some facilities. Recent activities K-edge subtraction method at the Accumulation Ring are briefly described here. (author)

  10. Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Juil [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Choi, Young Hun [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Pak, Seong Yong [Siemens Healthineers, Seoul (Korea, Republic of); Krauss, Bernhard [Siemens Healthineers, Forchheim (Germany)

    2017-11-15

    Advanced virtual monochromatic reconstruction from dual-energy brain CT has not been evaluated in children. To determine the most effective advanced virtual monochromatic imaging energy level for maximizing pediatric brain parenchymal image quality in dual-energy unenhanced brain CT and to compare this technique with conventional monochromatic reconstruction and polychromatic scanning. Using both conventional (Mono) and advanced monochromatic reconstruction (Mono+) techniques, we retrospectively reconstructed 13 virtual monochromatic imaging energy levels from 40 keV to 100 keV in 5-keV increments from dual-source, dual-energy unenhanced brain CT scans obtained in 23 children. We analyzed gray and white matter noise ratios, signal-to-noise ratios and contrast-to-noise ratio, and posterior fossa artifact. We chose the optimal mono-energetic levels and compared them with conventional CT. For Mono+maximum optima were observed at 60 keV, and minimum posterior fossa artifact at 70 keV. For Mono, optima were at 65-70 keV, with minimum posterior fossa artifact at 75 keV. Mono+ was superior to Mono and to polychromatic CT for image-quality measures. Subjective analysis rated Mono+superior to other image sets. Optimal virtual monochromatic imaging using Mono+ algorithm demonstrated better image quality for gray-white matter differentiation and reduction of the artifact in the posterior fossa. (orig.)

  11. Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography.

    Science.gov (United States)

    Park, Juil; Choi, Young Hun; Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One; Pak, Seong Yong; Krauss, Bernhard

    2017-11-01

    Advanced virtual monochromatic reconstruction from dual-energy brain CT has not been evaluated in children. To determine the most effective advanced virtual monochromatic imaging energy level for maximizing pediatric brain parenchymal image quality in dual-energy unenhanced brain CT and to compare this technique with conventional monochromatic reconstruction and polychromatic scanning. Using both conventional (Mono) and advanced monochromatic reconstruction (Mono+) techniques, we retrospectively reconstructed 13 virtual monochromatic imaging energy levels from 40 keV to 100 keV in 5-keV increments from dual-source, dual-energy unenhanced brain CT scans obtained in 23 children. We analyzed gray and white matter noise ratios, signal-to-noise ratios and contrast-to-noise ratio, and posterior fossa artifact. We chose the optimal mono-energetic levels and compared them with conventional CT. For Mono+maximum optima were observed at 60 keV, and minimum posterior fossa artifact at 70 keV. For Mono, optima were at 65-70 keV, with minimum posterior fossa artifact at 75 keV. Mono+ was superior to Mono and to polychromatic CT for image-quality measures. Subjective analysis rated Mono+superior to other image sets. Optimal virtual monochromatic imaging using Mono+ algorithm demonstrated better image quality for gray-white matter differentiation and reduction of the artifact in the posterior fossa.

  12. Data on incident solar energy

    Science.gov (United States)

    Thekaekara, M. P.

    1974-01-01

    Instrumentation for solar irradiance monitoring, and radiation scales are discussed in a survey of incident solar energy data. The absolute accuracy and intrinsic reliability of the values of the solar constant and zero air mass solar spectrum proposed by the Institute of Environmental Sciences as an ASTM standard are evaluated. Extraterrestrial observations are used for deriving solar irradiance data at ground level for widely varying atmospheric parameters, with special reference to air pollution. The effects of diffuse sky radiance and those of varying slopes of the solar energy collecting surface are examined. Average values of solar energy available at different locations in the United States are included.

  13. Extension and Spatial Distribution of Atherosclerotic Burden Using Virtual Monochromatic Imaging Derived From Dual-energy Computed Tomography.

    Science.gov (United States)

    Rodríguez-Granillo, Gastón A; Carrascosa, Patricia; Deviggiano, Alejandro; Capunay, Carlos; de Zan, Macarena C; Goldsmit, Alejandro

    2016-10-01

    We explored the differences between atherosclerotic burden with invasive coronary angiography and virtual monochromatic imaging derived from dual-energy computed tomography coronary angiography. Eighty consecutive patients referred for invasive coronary angiography underwent dual-energy computed tomography coronary angiography and were categorized according to the atherosclerotic burden extent using the modified Duke prognostic coronary artery disease index, coronary artery disease extension score, segment involvement score, and the segment stenosis score. The mean segment involvement score (8.2 ± 3.9 vs 6.0 ± 3.7; P < .0001), modified Duke index (4.33 ± 1.6 vs 4.0 ± 1.7; P = .003), coronary artery disease extension score (4.84 ± 1.8 vs 4.43 ± 2.1; P = .005), and the median segment stenosis score (13.5 [9.0-18.0] vs 9.5 [5.0-15.0]; P < .0001) were significantly higher on dual-energy computed tomography compared with invasive angiography. Dual-energy computed tomography showed a significantly higher number of patients with any left main coronary artery lesion (46 [58%] vs 18 [23%]; P < .0001) and with severe proximal lesions (0.28 ± 0.03 vs 0.26 ± 0.03; P < .0001) than invasive angiography. Levels of coronary artery calcification below and above the median showed a sensitivity, specificity, positive predictive value, and negative predictive value of 100% and 97%; 86% and 50%; 93% and 95%; 100% and 67% for the identification of ≥ 50% stenosis. Dual-energy computed tomography coronary angiography identified a significantly larger atherosclerotic burden compared with invasive coronary angiography, particularly involving the proximal segments. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  14. Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager.

    Science.gov (United States)

    Nagayama, T; Mancini, R C; Mayes, D; Tommasini, R; Florido, R

    2015-11-01

    Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. Here, we synthetically quantify the accuracy of images and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ∼6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ∼10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. It is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application.

  15. Impact of different monochromatic LED light colours and bird age on the behavioural output and fear response in ducks

    Directory of Open Access Journals (Sweden)

    Shabiha Sultana

    2013-12-01

    Full Text Available This study was performed to observe the effect of monochromatic light emitting diode (LED light colour and bird age on the behaviour and fear response of ducks. A total of 200 1-day-old ducklings were used in the experiment (two replications, 25 ducklings/pen, and lighting was set up as follows: white (W, control, 400-770 nm, yellow (Y, 600 nm, green (G, 520 nm and blue (B, 460 nm LED lights. Ducks were subjected to 23L: 1D h lighting with 0.1 Watt/m2 light intensity. Video was recorded twice per day (2 h in the morning and 2 h in the afternoon and observed five consecutive days per week. Duration of feeding, drinking, sitting, walking, standing, preening, wing flapping, wing stretching, tail wagging, head shaking, body shaking, ground pecking, peck object, and social interaction behaviour were recorded. At 3 and 6 weeks of age, 10 birds per treatment were subjected to the tonic immobility (TI test (three times/duck. Ducks reared in Y and W light were more active, as expressed by more walking, ground pecking, drinking and social interaction activities than those of ducks under the B light treatment (P<0.05. Ducks showed more time sitting, standing, and preening under B light (P<0.05. Feeding, sitting, standing and drinking behaviours increased, and walking and social interaction behaviours decreased with age of the ducks (P<0.05. Differences in behaviours among different light colours were observed. In addition, the TI test results indicated that B and G light reduced the fear response of the ducks.

  16. Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager

    Science.gov (United States)

    Nagayama, T.; Mancini, R. C.; Mayes, D.; Tommasini, R.; Florido, R.

    2015-11-01

    Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. Here, we synthetically quantify the accuracy of images and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ˜6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ˜10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. It is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application.

  17. Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager

    International Nuclear Information System (INIS)

    Nagayama, T.; Mancini, R. C.; Mayes, D.; Tommasini, R.; Florido, R.

    2015-01-01

    Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. Here, we synthetically quantify the accuracy of images and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ∼6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ∼10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. It is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application

  18. Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Wellenberg, R.H.H., E-mail: r.h.wellenberg@amc.uva.nl [Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Boomsma, M.F., E-mail: m.f.boomsma@isala.nl [Department of Radiology, Isala, Zwolle (Netherlands); Osch, J.A.C. van, E-mail: j.a.c.van.osch@isala.nl [Department of Radiology, Isala, Zwolle (Netherlands); Vlassenbroek, A., E-mail: alain.vlassenbroek@philips.com [Philips Medical Systems, Brussels (Belgium); Milles, J., E-mail: julien.milles@philips.com [Philips Medical Systems, Eindhoven (Netherlands); Edens, M.A., E-mail: m.a.edens@isala.nl [Department of Innovation and Science, Isala, Zwolle (Netherlands); Streekstra, G.J., E-mail: g.j.streekstra@amc.uva.nl [Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Slump, C.H., E-mail: c.h.slump@utwente.nl [MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede (Netherlands); Maas, M., E-mail: m.maas@amc.uva.nl [Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands)

    2017-03-15

    Highlights: • Dual-layer detector CT reduces metal artefacts at high monochromatic energies (keV). • 130 keV images were optimal based on quantitative analysis on CNRs. • Optimal keVs varied from 74 to 150 keV for different hip prostheses configurations. • The Titanium alloy resulted in less severe artefacts compared to the Cobalt alloy. • Severe metal artefacts, caused by extensive photon-starvation, were not reduced. - Abstract: Purpose: To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. Methods: The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer detector Spectral CT scanner at 120-kVp and 140-kVp at a standard computed tomography dose index of 20.0 mGy. Several unilateral and bilateral hip prostheses consisting of different metal alloys were inserted and combined which were surrounded by 18 hydroxyapatite calcium carbonate pellets representing bone. Images were reconstructed with iterative reconstruction and analysed at monochromatic energies ranging from 40 to 200 keV. CT numbers in Hounsfield Units (HU), noise measured as the standard deviation in HU, signal-to-noise-ratios (SNRs) and contrast-to-noise-ratios (CNRs) were analysed within fixed regions-of-interests placed in and around the pellets. Results: In 70 and 74 keV virtual monochromatic images the CT numbers of the pellets were similar to 120-kVp and 140-kVp polychromatic results, therefore serving as reference. A separation into three categories of metal artefacts was made (no, mild/moderate and severe) where pellets were categorized based on HU deviations. At high keV values overall image contrast was reduced. For mild/moderate artefacts, the highest average CNRs were attained with virtual monochromatic 130 keV images, acquired at 140-kVp. Severe metal artefacts were not reduced. In 130 keV images

  19. Photomorphogenic effects of UV-B radiation on plants: consequences for light competition

    International Nuclear Information System (INIS)

    Barnes, P.W.; Ballaré, C.L.; Caldwell, M.M.

    1996-01-01

    A combination of field and labotatory studies were conducted to explore the nature of photomorphogenic effects of ultraviolet-B radiation (UV-B; 280–320 nm) on plant morphology and to evaluate the ecological consequences of these alterations in morphology for interspecific competition. Under laboratory conditions, seedlings of cucumber (Cucumis sativus L.) and tomato (Lycopersicon esculentum Mill.) exhibited appreciable (ca. 50%) and rapid (< 3h) inhibition in hypocotyl elongation in response to UV-B exposure. In cucumber, this inhibition was reversible, occurred without any associated changes in dry matter production and was caused by UV-B incident on the cotyledons and not the stem or growing tip. Inhibition of stem elongation in etiolated tomato seedlings occurred at least 3 h prior to the onset of accumulation of UV-absorbing pigments and monochromatic UV supplied against a background of visible radiation revealed maximum effectiveness in inhibition around 300 nm. Collectively, these findings suggest that a specific, but yet unidentified, UV-B photoreceptor is involved in mediating certain morphological responses to UV-B. For mixtures of wheat (Triticum aestivum L.) and wild oat (Avena fatua L.), a common weedy competitor, supplemental UV-B irradiation in the field differentially altered shoot morphology which resulted in changes in canopy structure, light interception and calculated stand photosynthesis. It is argued that, because of its asymmetrical nature, competition for light can potentially amplify the effects of UV-B on shoot morphology and may, therefore, be an important mechanism by which changes in the solar UV-B spectrum associated with stratospheric ozone reduction could alter the composition and character of terrestrial vegetation

  20. MCFRS Incidents by Station

    Data.gov (United States)

    Montgomery County of Maryland — This dataset contains the monthly summary data indicating incident occurred in each fire station response area. The summary data is the incident count broken down by...

  1. Police Incident Reports Written

    Data.gov (United States)

    Town of Chapel Hill, North Carolina — This table contains incident reports filed with the Chapel Hill Police Department. Multiple incidents may have been reported at the same time. The most serious...

  2. Radiation-shielded double crystal X-ray monochromator for JET

    International Nuclear Information System (INIS)

    Barnsley, R.; Morsi, H.W.; Rupprecht, G.; Kaellne, E.

    1989-01-01

    A double crystal X-ray monochromator for absolute wavelength and intensity measurements with very effective shielding of its detector against neutrons and hard X-rays was brought into operation at JET. Fast wavelength scans were taken of impurity line radiation in the wavelength region from about 0.1 nm to 2.3 nm, and monochromatic as well as spectral line scans, for different operational modes of JET. (author) 5 refs., 4 figs

  3. Parallel beam microradiography of dental hard tissue using synchrotron radiation and X-ray image magnification

    International Nuclear Information System (INIS)

    Takagi, S.; Chow, L.C.; Brown, W.E.; Dobbyn, R.C.; Kuriyama, M.

    1984-01-01

    A novel technique utilizing a highly parallel beam of monochromatic synchrotron radiation combined with X-ray image magnification has been used to obtain microradiographs of caries lesions in relatively thick tooth sections. Preliminary results reveal structural features not previously reported. This technique holds the promise of allowing one to follow the structural changes accompanying the formation, destruction and chemical repair of mineralized tissue in real time. (orig.)

  4. AlGaAs/GaAs photovoltaic converters for high power narrowband radiation

    Energy Technology Data Exchange (ETDEWEB)

    Khvostikov, Vladimir; Kalyuzhnyy, Nikolay; Mintairov, Sergey; Potapovich, Nataliia; Shvarts, Maxim; Sorokina, Svetlana; Andreev, Viacheslav [Ioffe Physical-Technical Institute, 26 Polytechnicheskaya, St. Petersburg, 194021 (Russian Federation); Luque, Antonio [Ioffe Physical-Technical Institute, 26 Polytechnicheskaya, St. Petersburg, 194021, Russia and Instituto de Energia Solar, Universidad Politecnica de Madrid, Madrid (Spain)

    2014-09-26

    AlGaAs/GaAs-based laser power PV converters intended for operation with high-power (up to 100 W/cm{sup 2}) radiation were fabricated by LPE and MOCVD techniques. Monochromatic (λ = 809 nm) conversion efficiency up to 60% was measured at cells with back surface field and low (x = 0.2) Al concentration 'window'. Modules with a voltage of 4 V and the efficiency of 56% were designed and fabricated.

  5. [Clinical applications of synchrotron radiation X-ray].

    Science.gov (United States)

    Uyama, C

    1994-09-01

    Synchrotron Radiation X-ray (SR X-ray) is an extremely strong X-ray source with a photon number more than 10(4) compared with that of the current X-ray tube. X-rays obtained by monochromatizing SR X-ray have been applied to new techniques for medical diagnosis. Several studies are now being conducted at the beam site for medical use at the Accumulation Ring of the High Energy Physics Research Institute, Tsukuba. Applications being studied include (1) energy subtraction coronary angiography. (2) microdetection of metas in samples excised from subjects. (3) monochromatic X-ray computed tomography and so on. Energy subtraction coronary angiography might have a safety advantage over the current selective coronary angiography. Microdetection of mandatory metals and poisonous heavy metals in in vivo samples contributes to the development of pathologic knowledge and clinical treatment of cancer and heavy metal toxications. Monochromatic X-ray CT is expected to detect diseases in the early stage due to increased accuracy in CT values.

  6. Radiation control

    International Nuclear Information System (INIS)

    Uchida, Akira

    1981-01-01

    This paper describes on how the condition of radiation level in the ring (storage ring) experimentation room changes corresponding to the operating stage of SOR-ring (synchrotron radiation storage ring), and does not describe on the present radiation control in the SOR facility. The operating stage of SOR is divided into the following five: (1) 307 MeV electron injection, (2) 307 MeV electron storage (used for SOR experiments), (3) energy increase from 307 to 380 MeV, (4) 380 MeV electron storage, (5) re-injection and completion of operation. Gamma and X ray levels are shown when electron beam is injected from the electron synchrotron to the SOR-ring. Two main causes of the high level are reported. Spatial dose rate in storing 307 MeV electrons in also illustrated. This is sufficiently lower than that at electron incidence. The measurement of radiation level at the time of energy increase from 307 to 380 MeV has just started. Since the radiation level in 380 MeV storage, measured at the points about 20 cm apart from the electron orbit, showed several mR/h, the level seems to be negligible at the points where experiments are carried out, 1 m away from the measurement points. The radiation level in electron reinjection and completion of operation may be large during a short period (a few Roentgen) like the time of energy increase. Therefore, the beam shall be re-injected or decreased after confirming that all experimenters have retreated into the predetermined place. (Wakatsuki, Y.)

  7. GLERL Radiation Transfer Through Freshwater Ice

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Radiation transmittance (ratio of transmitted to incident radiation) through clear ice, refrozen slush ice and brash ice, from ice surface to ice-water interface in...

  8. Incident Information Management Tool

    CERN Document Server

    Pejovic, Vladimir

    2015-01-01

    Flaws of\tcurrent incident information management at CMS and CERN\tare discussed. A new data\tmodel for future incident database is\tproposed and briefly described. Recently developed draft version of GIS-­‐based tool for incident tracking is presented.

  9. Radiative defluorination of poly (vinylidene fluoride) under soft X-ray radiation

    International Nuclear Information System (INIS)

    Chebotaryov, S.S.; Baitinger, E.M.; Volegov, A.A.; Margamov, I.G.; Gribov, I.V.; Moskvina, N.A.; Kuznetsov, V.L.; Evsyukov, S.E.; Pesin, L.A.

    2006-01-01

    The rates of poly (vinylidene fluoride) (PVDF) degradation under synchrotron (SR) and conventional X-ray radiation have been measured and compared. NEXAFS spectra of fluorine show significant changes in their shape and intensity with elevation of radiation dose (or duration of SR exposure). Non-monochromatic AlK α radiation and the flow of secondary electrons accompanying it also cause surface degradation of PVDF. XPS allows one to measure relative content of fluorine by three ways: via relative intensities of F2s/C1s, F1s/C1s, spectra and using the features arising due to of C1s peaks in CF 2 and CF groups

  10. Design of a dedicated beamline for THz coherent synchrotron radiation at UVSOR-III

    International Nuclear Information System (INIS)

    Kimura, Shin-ichi; Nakamura, Eiken; Imura, Keiichiro; Katoh, Masahiro; Hosaka, Masahito; Takahashi, Toshiharu

    2012-01-01

    We report the design of a THz beamline for coherent synchrotron radiation (CSR) at the UVSOR-III very-low-emittance synchrotron radiation light source. The emitted THz-CSR is collected by a three-dimensional 'magic mirror', which is a perfect collecting mirror for bending-magnet radiation with an acceptance angle of 288 mrad (H) × 80 mrad (V). A quasi-monochromatic THz-CSR with an average flux of 104 μW/0.1 % b.w. and a peak power of 120 nJ/pulse/0.1 % b.w. is expected at the beamline.

  11. Theory of the special Smith-Purcell radiation from a rectangular grating

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Weihao, E-mail: liuwhao@ustc.edu.cn; He, Zhigang, E-mail: hezhg@ustc.edu.cn; Jia, Qika [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui, 230029 (China); Li, Weiwei [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui, 230029 (China); Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, via E. Fermi 40, 00044 Frascati, RM (Italy)

    2015-12-15

    The recently uncovered special Smith-Purcell radiation (S-SPR) from the rectangular grating has significantly higher intensity than the ordinary Smith-Purcell radiation (SPR). Its monochromaticity and directivity are also much better. Here we explored the mechanism of the S-SPR by applying the fundamental electromagnetic theory and simulations. We have confirmed that the S-SPR is exactly from the radiating eigen modes of the grating. Its frequency and direction are well correlated with the beam velocity and structure parameters, which indicates its promising applications in tunable wave generation and beam diagnostic.

  12. Theory of the special Smith-Purcell radiation from a rectangular grating

    International Nuclear Information System (INIS)

    Liu, Weihao; He, Zhigang; Jia, Qika; Li, Weiwei

    2015-01-01

    The recently uncovered special Smith-Purcell radiation (S-SPR) from the rectangular grating has significantly higher intensity than the ordinary Smith-Purcell radiation (SPR). Its monochromaticity and directivity are also much better. Here we explored the mechanism of the S-SPR by applying the fundamental electromagnetic theory and simulations. We have confirmed that the S-SPR is exactly from the radiating eigen modes of the grating. Its frequency and direction are well correlated with the beam velocity and structure parameters, which indicates its promising applications in tunable wave generation and beam diagnostic

  13. Workplace photon radiation fields

    International Nuclear Information System (INIS)

    Burgess, P.H.; Bartlett, D.T.; Ambrosi, P.

    1999-01-01

    The knowledge of workplace radiation fields is essential for measures in radiation protection. Information about the energy and directional distribution of the incident photon radiation was obtained by several devices developed by the National Radiation Protection Board, United Kingdom, by the Statens Stralskyddsinstitut, Sweden, together with EURADOS and by the Physikalisch-Technische Bundesanstalt, Germany. The devices are described and some results obtained at workplaces in nuclear industry, medicine and science in the photon energy range from 20 keV to 7 MeV are given. (author)

  14. An introduction to radiation protection

    CERN Document Server

    Martin, Alan; Beach, Karen; Cole, Peter

    2012-01-01

    The sixth edition of this established text takes the reader through the general background to the subject, the technical principles underlying the control of radiation hazards, radiation detection and measurement and the biological effects of radiation. These are followed by a consideration of radiation protection issues in the nuclear industry, the non-nuclear sector and the medical field. Further specialised topics include risk assessment, waste management and decommissioning, radiological incidents and emergencies, relevant legislation and organizational issues.

  15. Changes of plasma growth hormone, insulin-like growth factors-I, thyroid hormones, and testosterone concentrations in embryos and broiler chickens incubated under monochromatic green light

    Directory of Open Access Journals (Sweden)

    Lin Zhang

    2014-07-01

    Full Text Available Previous studies showed that monochromatic green light stimuli during embryogenesis accelerated posthatch body weight and pectoral muscle growth of broilers. In this experiment, we further investigated whether the regulation of broiler embryonic or posthatch growth by green light stimulus during incubation is associated with the changes of some important hormones at different ages of embryos and broiler chickens. Fertile broiler eggs (Arbor Acres, n=880 were pre-weighed and randomly assigned 1 of 2 incubation treatment groups: i dark condition (control group, and ii monochromatic green light group (560 nm. The monochromatic lighting systems sourced from light-emitting diode lamps were equalised at the intensity of 15 lux (lx at eggshell level. The dark condition was set as a commercial control from day one until hatching. After hatch, 120 day-old male chicks from each group were housed under white light with an intensity of 30 lx at bird-head level. Compared with the dark condition, chicks incubated under the green light showed significantly higher growth hormone (GH levels from 19 d of embryogenesis (E19 to 5 d of posthatch (H5, and higher plasma insulinlike growth factor (IGF-I levels from both E17 to E19 and H3 to H35. No significant differences were found in plasma thyroxine, triiodothyronine, and testosterone in embryos or hatched birds between the 2 groups. These results indicate that somatotropic axis hormones (GH and IGF-I may be the most important contributor to chicken growth promoted by green light stimuli during embryogenesis.

  16. Health of radiation workers

    International Nuclear Information System (INIS)

    Myers, D.K.

    1979-11-01

    Radiation workers are healthier than the average person in the general population and appear to be as healthy as workers in other ΣsafeΣ industries. It is, however, assumed that there is no safe dose of radiation and that any exposure to radiation will cause a small increase in the incidence of cancer, this increase being directly proportional to the total radiation dose. On the basis of the risk estimates given by ICRP, radiation exposures up to 1 rem per year for 47 years are predicted to cause fewer work-related deaths than expected for the average worker in Canadian industry. Radiation exposures of 5 rem per year from age 18 to 65 would result in predicted risk which is about four times higher than that for most workers in Canada and might increase the chances of death before age 75 to nearly the same level as for the average member of the general public. (auth)

  17. Free-Free Transitions in the Presence of Laser Fields and Debye Potential at Very Low Incident Electron Energies

    Science.gov (United States)

    Bhatia, Anand

    2012-01-01

    We study the free-free transition in electron-helium ion in the ground state and embedded in a Debye potential in the presence of an external laser field at very low incident electron energies. The laser field is treated classically while the collision dynamics is treated quantum mechanically. The laser field is chosen as monochromatic, linearly polarized and homogeneous. The incident electron is considered to be dressed by the laser field in a nonperturbative manner by choosing Volkov wave function for it. The scattering wave function for the incident electron on the target embedded in a Debye potential is solved numerically by taking into account the effect of electron exchange. We calculate the laser-assisted differential and total cross sections for free-free transition for absorption/emission of a single photon or no photon exchange. The results will be presented at the conference.

  18. Naturally occurring and radiation-induced tumors in SPF mice, and genetic influence in radiation leukemogenesis

    International Nuclear Information System (INIS)

    Kasuga, T.

    1979-01-01

    The data obtained so far in this study point to a strong genetic influence not only on the types and incidence of naturally occurring and radiation-induced tumors but also on radiation leukemogenesis. (Auth.)

  19. Study of electron densities of normal and neoplastic human breast tissues by Compton scattering using synchrotron radiation

    International Nuclear Information System (INIS)

    Antoniassi, M.; Conceição, A.L.C.; Poletti, M.E.

    2012-01-01

    Electron densities of 33 samples of normal (adipose and fibroglangular) and neoplastic (benign and malignant) human breast tissues were determined through Compton scattering data using a monochromatic synchrotron radiation source and an energy dispersive detector. The area of Compton peaks was used to determine the electron densities of the samples. Adipose tissue exhibits the lowest values of electron density whereas malignant tissue the highest. The relationship with their histology was discussed. Comparison with previous results showed differences smaller than 4%. - Highlights: ► Electron density of normal and neoplastic breast tissues was measured using Compton scattering. ► Monochromatic synchrotron radiation was used to obtain the Compton scattering data. ► The area of Compton peaks was used to determine the electron densities of samples. ► Adipose tissue shows the lowest electron density values whereas the malignant tissue the highest. ► Comparison with previous results showed differences smaller than 4%.

  20. Two-Dimensional Electron System in Electromagnetic Radiation Field

    Science.gov (United States)

    Lungu, Radu Paul; Manolescu, Andrei

    We consider a two-dimensional electron gas in the presence of a monochromatic linear polarized electromagnetic field, within the Floquet formalism. The Floquet states have a simple relation with the energy eigenstates in the absence of the field. Therefore the single-particle and the two-particle Green functions of the many-body system with Coulomb interactions, in the radiation field, can be formally calculated by the standard diagrammatic techniques, as for the conservative system. We derive the elementary excitations of quasi-particle type, the plasma dispersion relation, and the ground state quasi-energy, and we relate them to the corresponding results for the conservative system.

  1. Direct detection of darkmatter in radiative seesaw model

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Daniel; Schwetz, Thomas [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Toma, Takashi [Institute for Theoretical Physics, Kanazawa University (Japan)

    2012-07-01

    In the radiative seesaw model proposed by Ma, we assume that the lightest right-handed neutrino is the Dark Matter candidate and almost degenerated with the second lightest right-handed neutrino. Thus, elastic Dark Matter-nucleus scattering is suppressed. Inelastic scattering is induced by a lepton-loop coupled to the photon. Effectively, there are charge-charge, dipole-charge and dipole-dipole interactions. We present the event rate of the model and compare it with existing data. Moreover, monochromatic photons from the decay of the excited Dark Matter state are discussed.

  2. Breast tomography with synchrotron radiation: preliminary results

    International Nuclear Information System (INIS)

    Pani, Silvia; Longo, Renata; Dreossi, Diego; Montanari, Francesco; Olivo, Alessandro; Arfelli, Fulvia; Bergamaschi, Anna; Poropat, Paolo; Rigon, Luigi; Zanconati, Fabrizio; Palma, Ludovico Dalla; Castelli, Edoardo

    2004-01-01

    A system for in vivo breast imaging with monochromatic x-rays has been designed and built at the synchrotron radiation facility Elettra in Trieste (Italy) and will be operational in 2004. The system design involves the possibility of performing both planar mammography and breast tomography. In the present work, the first results obtained with a test set-up for breast tomography are shown and discussed. Tomographic images of in vitro breasts were acquired using monochromatic x-ray beams in the energy range 20-28 keV and a linear array silicon pixel detector. Tomograms were reconstructed using standard filtered backprojection algorithms; the effect of different filters was evaluated. The attenuation coefficients of fibroglandular and adipose tissue were measured, and a quantitative comparison of images acquired at different energies was performed by calculating the differential signal-to-noise ratio of fibroglandular details in adipose tissue. All images required a dose comparable to the dose delivered in clinical, conventional mammography and showed a high resolution of the breast structures without the overlapping effects that limit the visibility of the structures in 2D mammography. A quantitative evaluation of the images proves that the image quality at a given dose increases in the considered energy range and for the considered breast sizes

  3. Cancer incidence study in Mesa County, Colorado

    International Nuclear Information System (INIS)

    Ouimette, D.R.; Ferguson, S.W.; Zoglo, D.; Murphy, S.; Alley, S.; Bahler, S.

    1983-01-01

    In November of 1982 the Colorado Department of Health completed an epidemiologic investigation of leukemia, multiple myeloma, and cancers of the lung, stomach, pancreas and colon in Mesa County, Colorado for the years 1970 to 1979. This investigation was performed in response to a concern that the presence of uranium mill tailings in some Mesa County homes presents a potential cancer hazard. The results of the investigation show that the incidence of multiple myeloma, colon, stomach and pancreatic cancer are not above expected rates. The incidence of leukemia is not above expected rates for the entire study period, 1970 to 1979. The incidence of lung cancer appears elevated when compared to the The Third National Cancer Survey data for Colorado but lower than expected when compared to Surveillance, Epidemiology and End Results data. To further examine the leukemia and lung cancer incidence findings, a case/control study was conducted. The controls consisted of colon, stomach and pancreatic cancer cases. The results of the leukemia case/control analysis show no association with the radiation exposure variables: occupational radiation exposure; uranium mining exposure; having ever lived in a type A home (uranium tailings home); and radiation therapy. The lung cancer case/control analysis shows a significant association with only the radiation exposure variable, uranium mining history, indicating cases were more likely to have been uranium miners than were controls. As with leukemia, the study found no association between lung cancer and living in a uranium mill tailings home. The relatively low radiation exposures typical of type A homes and the small number of persons exposed make it very difficult to establish, by epidemiologic methods, that a risk exists

  4. Cancer incidence among Nordic airline cabin crew.

    Science.gov (United States)

    Pukkala, Eero; Helminen, Mika; Haldorsen, Tor; Hammar, Niklas; Kojo, Katja; Linnersjö, Anette; Rafnsson, Vilhjálmur; Tulinius, Hrafn; Tveten, Ulf; Auvinen, Anssi

    2012-12-15

    Airline cabin crew are occupationally exposed to cosmic radiation and jet lag with potential disruption of circadian rhythms. This study assesses the influence of work-related factors in cancer incidence of cabin crew members. A cohort of 8,507 female and 1,559 male airline cabin attendants from Finland, Iceland, Norway and Sweden was followed for cancer incidence for a mean follow-up time of 23.6 years through the national cancer registries. Standardized incidence ratios (SIRs) were defined as ratios of observed and expected numbers of cases. A case-control study nested in the cohort (excluding Norway) was conducted to assess the relation between the estimated cumulative cosmic radiation dose and cumulative number of flights crossing six time zones (indicator of circadian disruption) and cancer risk. Analysis of breast cancer was adjusted for parity and age at first live birth. Among female cabin crew, a significantly increased incidence was observed for breast cancer [SIR 1.50, 95% confidence interval (95% CI) 1.32-1.69], leukemia (1.89, 95% CI 1.03-3.17) and skin melanoma (1.85, 95% CI 1.41-2.38). Among men, significant excesses in skin melanoma (3.00, 95% CI 1.78-4.74), nonmelanoma skin cancer (2.47, 95% CI 1.18-4.53), Kaposi sarcoma (86.0, 95% CI 41.2-158) and alcohol-related cancers (combined SIR 3.12, 95% CI 1.95-4.72) were found. This large study with complete follow-up and comprehensive cancer incidence data shows an increased incidence of several cancers, but according to the case-control analysis, excesses appear not to be related to the cosmic radiation or circadian disruptions from crossing multiple time zones. Copyright © 2012 UICC.

  5. Rapid determination of trace phosphorus, sulfur, chlorine, bromine and iodine by energy dispersive X-ray fluorescence analysis with monochromatic excitations

    International Nuclear Information System (INIS)

    Wakisaka, Tatsushi; Morita, Naoki; Hirabayashi, Tadashi; Nakahara, Taketoshi

    1998-01-01

    A useful and rapid procedure is described for the determination of trace phosphorus, sulfur, chlorine, bromine, and iodine by means of an energy dispersive X-ray fluorescence spectrometer (EDXRF) with monochromatic excitations. Using monochromatic excitations, the detection limits for phosphorus, sulfur, chlorine (Cr-Kα, 5.41 keV), bromine (Mo-Kα, 17.44 keV), and iodine (W-continuum, 40 keV) were found to be 4.6, 1.7, 0.7, 0.09 and 0.5 μg g -1 , respectively. The relative standard deviations in five replicate measurements were 0.9-1.3%. The proposed method was applied to the direct determination of sulfur in the NIST Residual Fuel Oil, and others. The results obtained by the proposed method were in good agreement with the certified values. Bromine in a seawater sample, as well as iodine and bromine in a brine sample were determined by the proposed method. The obtained results were in good agreement with those obtained by ion chromatography. (author)

  6. Relative efficiency calibration between two silicon drift detectors performed with a monochromatized X-ray generator over the 0.1-1.5 keV range

    Science.gov (United States)

    Hubert, S.; Boubault, F.

    2018-03-01

    In this article, we present the first X-ray calibration performed over the 0.1-1.5 keV spectral range by means of a soft X-ray Manson source and the monochromator SYMPAX. This monochromator, based on a classical Rowland geometry, presents the novelty to be able to board simultaneously two detectors and move them under vacuum in front of the exit slit of the monochromatizing stage. This provides the great advantage to perform radiometric measurements of the monochromatic X-ray photon flux with one reference detector while calibrating another X-ray detector. To achieve this, at least one secondary standard must be operated with SYMPAX. This paper presents thereby an efficiency transfer experiment between a secondary standard silicon drift detector (SDD), previously calibrated on BESSY II synchrotron Facility, and another one ("unknown" SDD), devoted to be used permanently with SYMPAX. The associated calibration process is described as well as corresponding results. Comparison with calibrated measurements performed at the Physikalisch-Technische Bundesanstalt (PTB) Radiometric Laboratory shows a very good agreement between the secondary standard and the unknown SDD.

  7. Acute incidents during anaesthesia

    African Journals Online (AJOL)

    Incidents can occur during induction, maintenance and emergence from anaesthesia. The following acute critical incidents are discussed in this article: • Anaphylaxis. • Aspiration ..... Already used in South Africa and Malawi, a scale-up of the technique is under way in Tanzania, Rwanda and Ghana. The report found that.

  8. Electron density measurement with dual-energy x-ray CT using synchrotron radiation

    International Nuclear Information System (INIS)

    Torikoshi, Masami; Tsunoo, Takanori; Sasaki, Makoto; Endo, Masahiro; Noda, Yutaka; Ohno, Yumiko; Kohno, Toshiyuki; Hyodo, Kazuyuki; Uesugi, Kentaro; Yagi, Naoto

    2003-01-01

    Monochromatic x-ray computed tomography (CT) at two different energies provides information about electron density of human tissue without ambiguity due to the beam hardening effect. This information makes the treatment planning for proton and heavy-ion radiotherapy more precise. We have started a feasibility study on dual energy x-ray CT by using synchrotron radiation. A translation-rotation scanning CT system was developed for quantitative measurement in order to clarify what precision in the measurement was achieved. Liquid samples of solutions of K 2 HPO 4 and solid samples of tissue equivalent materials were used to simulate human tissue. The experiments were carried out using monochromatic x-rays with energies of 40, 70 and 80 keV produced by monochromatizing synchrotron radiation. The solid samples were also measured in a complementary method using high-energy carbon beams to evaluate the electron densities. The measured electron densities were compared with the theoretical values or the values measured in the complementary method. It was found that these values were in agreement in 0.9% on average. Effective atomic numbers were obtained as well from dual-energy x-ray CT. The tomographic image based on each of the electron densities and the effective atomic number presents a different feature of the material, and its contrast drastically differs from that in a conventional CT image

  9. Numerically stable algorithm for discrete-ordinate-method radiative transfer in multiple scattering and emitting layered media

    Science.gov (United States)

    Stamnes, Knut; Tsay, S.-CHEE; Jayaweera, Kolf; Wiscombe, Warren

    1988-01-01

    The transfer of monochromatic radiation in a scattering, absorbing, and emitting plane-parallel medium with a specified bidirectional reflectivity at the lower boundary is considered. The equations and boundary conditions are summarized. The numerical implementation of the theory is discussed with attention given to the reliable and efficient computation of eigenvalues and eigenvectors. Ways of avoiding fatal overflows and ill-conditioning in the matrix inversion needed to determine the integration constants are also presented.

  10. Effect of radiation environment on radiation use efficiency and growth of sunflower

    International Nuclear Information System (INIS)

    Bange, M.P.; Hammer, G.L.; Rickert, K.G.

    1997-01-01

    The level of incident radiation and the proportion of radiation that is diffuse affects radiation use efficiency (RUE) in crops. However, the degree of this effect, and its importance to growth and yield of sunflower (Helianthus annuus L.) have not been established. A field experiment was conducted to investigate the effects of radiation environment on RUE, growth, and yield of sunflower. A fully irrigated crop was sown on an alluvial-prairie soil (Fluventic Haplustoll) and was exposed to three distinct radiation environments. In two treatments, the level of incident radiation was reduced by 14 and 20% by suspending two different types of polyethylene plastic films well above the crop. In addition to the reductions in incident radiation, the proportion of radiation that was diffuse was increased by about 14% in these treatments. Lower incident radiation and increased proportion of diffuse radiation had no effect on total biomass, phenology, leaf area, and the canopy light extinction coefficient (k = 0.89). However, yield was reduced in shaded treatments due to smaller grain size and lower harvest index. Although crop RUE measured over the entire crop cycle (1.25 g/MJ) did not differ significantly among treatments, there was a trend where RUE compensated for less intercepted incident radiation. Theoretical derivations of the response of RUE to different levels of incident radiation supported this finding. Shaded sunflower crops have the ability to produce biomass similar to unshaded crops by increasing RUE, but have lower harvest indices

  11. Low dose radiation and plant growth

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Jae; Lee, Hae Youn; Park, Hong Sook

    2001-03-01

    Ionizing radiation includes cosmic radiation, earth radiation, radionuclides for the medical purpose and nuclear industry, fallout radiation. From the experimental results of various radiation effects on seeds or seedlings, it was found that germination rate, development, respiration rate, reproduction and blooming were accelerated compared with the control. In mammal, hormesis phenomenon manifested itself in increased disease resistance, lifespan, and decreased rate of tumor incidence. In plants, it was shown that germination, sprouting, growth, development, blooming and resistance to disease were accelerated.

  12. The hazards of low-level radiation

    International Nuclear Information System (INIS)

    Blackith, R.

    1979-01-01

    Safety standards are questioned, particularly in relation to the risk of inducing cancer at low doses of radiation. Statements are made on the following topics: incidence of leukaemia among children around reactors, general aging effect due to radiation, leukaemia among radiation workers in a shipyard repairing nuclear submarines, official withdrawal of funds from research workers in the field of radiation hazards, discrepancies between different measurements of radiation near nuclear power plants. (U.K.)

  13. Low dose radiation and plant growth

    International Nuclear Information System (INIS)

    Kim, Sung Jae; Lee, Hae Youn; Park, Hong Sook

    2001-03-01

    Ionizing radiation includes cosmic radiation, earth radiation, radionuclides for the medical purpose and nuclear industry, fallout radiation. From the experimental results of various radiation effects on seeds or seedlings, it was found that germination rate, development, respiration rate, reproduction and blooming were accelerated compared with the control. In mammal, hormesis phenomenon manifested itself in increased disease resistance, lifespan, and decreased rate of tumor incidence. In plants, it was shown that germination, sprouting, growth, development, blooming and resistance to disease were accelerated

  14. Non-Directional Radiation Spread Modeling and Non-Invasive Estimating the Radiation Scattering and Absorption Parameters in Biological Tissue

    Directory of Open Access Journals (Sweden)

    S. Yu. Makarov

    2015-01-01

    Full Text Available The article dwells on a development of new non-invasive measurement methods of optical parameters of biological tissues, which are responsible for the scattering and absorption of monochromatic radiation. It is known from the theory of radiation transfer [1] that for strongly scattering media, to which many biological tissues pertain, such parameters are parameters of diffusion approximation, as well as a scattering coefficient and an anisotropy parameter.Based on statistical modeling the paper examines a spread of non-directional radiation from a Lambert light beam with the natural polarization that illuminates a surface of the biological tissue. Statistical modeling is based on the Monte Carlo method [2]. Thus, to have the correct energy coefficient values of Fresnel reflection and transmission in simulation of such radiation by Monte Carlo method the author uses his finding that is a function of the statistical representation for the incidence of model photons [3]. The paper describes in detail a principle of fixing the power transmitted by the non-directional radiation into biological tissue [3], and the equations of a power balance in this case.Further, the paper describes the diffusion approximation of a radiation transfer theory, often used in simulation of radiation propagation in strongly scattering media and shows its application in case of fixing the power transmitted into the tissue. Thus, to represent an uneven power distribution is used an approximating expression in conditions of fixing a total input power. The paper reveals behavior peculiarities of solution on the surface of the biological tissue inside and outside of the incident beam. It is shown that the solution in the region outside of the incident beam (especially far away from it, essentially, depends neither on the particular power distribution across the surface, being a part of the tissue, nor on the refractive index of the biological tissue. It is determined only by

  15. Psoriasis and ultraviolet radiation

    International Nuclear Information System (INIS)

    Farber, E.M.; Nall, L.

    1993-01-01

    Prevention and detection screening programs as a public health service in curtailing the ever-increasing incidence of all forms of skin cancer are reviewed. The effect of solar and artificial ultraviolet radiation on the general population and persons with psoriasis is examined. 54 refs

  16. Vector radiative transfer code SORD: Performance analysis and quick start guide

    Science.gov (United States)

    Korkin, Sergey; Lyapustin, Alexei; Sinyuk, Alexander; Holben, Brent; Kokhanovsky, Alexander

    2017-10-01

    We present a new open source polarized radiative transfer code SORD written in Fortran 90/95. SORD numerically simulates propagation of monochromatic solar radiation in a plane-parallel atmosphere over a reflecting surface using the method of successive orders of scattering (hence the name). Thermal emission is ignored. We did not improve the method in any way, but report the accuracy and runtime in 52 benchmark scenarios. This paper also serves as a quick start user's guide for the code available from ftp://maiac.gsfc.nasa.gov/pub/skorkin, from the JQSRT website, or from the corresponding (first) author.

  17. Radiation protection

    International Nuclear Information System (INIS)

    Koelzer, W.

    1975-01-01

    Physical and radiological terms, quantities, and units. Basic principles of radiation protection (ICRP, IAEA, EURATOM, FRG). Biological effects of ionizing radiation. Objectives of practical radiation protection. (HP) [de

  18. Critical incident stress management.

    Science.gov (United States)

    Lim, J J; Childs, J; Gonsalves, K

    2000-10-01

    Recent studies have indicated implementation of the CISM Program has impacted and reduced the cost of workers' compensation claims for stress related conditions and the number of lost work days (Ott, 1997; Western Management Consultants, 1996). Occupational health professionals need to be ready to develop and implement a comprehensive critical incident stress management process in anticipation of a major event. The ability to organize, lead, or administer critical incident stress debriefings for affected employees is a key role for the occupational health professional. Familiarity with these concepts and the ability to identify a critical incident enhances value to the business by mitigating the stress and impact to the workplace. Critical Incident Stress Management Systems have the potential for decreasing stress and restoring employees to normal life function--a win/win situation for both the employees and the organization.

  19. Marine Animal Incident Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Large whale stranding, death, ship strike and entanglement incidents are all recorded to monitor the health of each population and track anthropogenic factors that...

  20. Police Incident Blotter (Archive)

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Police Blotter Archive contains crime incident data after it has been validated and processed to meet Uniform Crime Reporting (UCR) standards, published on a...

  1. Prediction of Safety Incidents

    Data.gov (United States)

    National Aeronautics and Space Administration — Safety incidents, including injuries, property damage and mission failures, cost NASA and contractors thousands of dollars in direct and indirect costs. This project...

  2. Light scattering reviews 8 radiative transfer and light scattering

    CERN Document Server

    Kokhanovsky, Alexander A

    2013-01-01

    Light scattering review (vol 8) is aimed at the presentation of recent advances in radiative transfer and light scattering optics. The topics to be covered include: scattering of light by irregularly shaped particles suspended in atmosphere (dust, ice crystals), light scattering by particles much larger as compared the wavelength of incident radiation, atmospheric radiative forcing, astrophysical radiative transfer, radiative transfer and optical imaging in biological media, radiative transfer of polarized light, numerical aspects of radiative transfer.

  3. Information Security Incident Management

    Directory of Open Access Journals (Sweden)

    D. I. Persanov

    2010-03-01

    Full Text Available The present report highlights the points of information security incident management in an enterprise. Some aspects of the incident and event classification are given. The author presents his view of the process scheme over the monitoring and processing information security events. Also, the report determines a few critical points of the listed process and gives the practical recommendations over its development and optimization.

  4. Minimal and maximal incidence rates of skin cancer in Caucasians estimated by use of sigmoidal UV dose-incidence curves.

    Science.gov (United States)

    Juzeniene, Asta; Grigalavicius, Mantas; Baturaite, Zivile; Moan, Johan

    2014-11-01

    Sigmoidal (S-shaped) dose-cancer incidence relationships are often observed in animal bioassays for carcinogenicity. Ultraviolet (UV) radiation is an established skin carcinogen. The aim of this study is to examine if S-shaped curves describe the relationship between solar UV doses and skin cancer incidences, and if such relationships can be used to estimate threshold levels of non-carcinogenic UV exposure, as well as maximal incidence rates. We studied the incidence rate-annual erythema-effective UV dose relationship for squamous cell carcinoma (SCC), basal cell carcinoma (BCC) and cutaneous melanoma (CM) among different Caucasian populations in Europe, Australia and New Zealand. Our analysis indicates that S-shaped associations describe the data well (P skin cancer was absent. Avoidance of UV radiation has a potential to reduce the incidence of skin cancer in fair-skinned population. Copyright © 2014 Elsevier GmbH. All rights reserved.

  5. Annual Conference on Nuclear and Space Radiation Effects, 15th, University of New Mexico, Albuquerque, N. Mex., July 18-21, 1978, Proceedings

    Science.gov (United States)

    Simons, M.

    1978-01-01

    Radiation effects in MOS devices and circuits are considered along with radiation effects in materials, space radiation effects and spacecraft charging, SGEMP, IEMP, EMP, fabrication of radiation-hardened devices, radiation effects in bipolar devices and circuits, simulation, energy deposition, and dosimetry. Attention is given to the rapid anneal of radiation-induced silicon-sapphire interface charge trapping, cosmic ray induced errors in MOS memory cells, a simple model for predicting radiation effects in MOS devices, the response of MNOS capacitors to ionizing radiation at 80 K, trapping effects in irradiated and avalanche-injected MOS capacitors, inelastic interactions of electrons with polystyrene, the photoelectron spectral yields generated by monochromatic soft X radiation, and electron transport in reactor materials.

  6. Self-powered radiation detector

    International Nuclear Information System (INIS)

    Playfoot, K.C.; Bauer, R.F.; Goldstein, N.P.

    1980-01-01

    This invention relates to a self powered radiation detector requiring no excitation potential to generate a signal indicating a radiation flux. Such detectors comprise two electrically insulated electrodes, at a distance from each other. These electrodes are made of conducting materials having a different response for neutron and/or gamma ray radiation flux levels, as in nuclear power stations. This elongated detector generates an electric signal in terms of an incident flux of radiations cooperating with coaxial conductors insulated from each other and with different radiation reaction characteristics. The conductor with the greatest reaction to the radiations forms the central emitting electrode and the conductor with the least reaction to the radiations forms a tubular coaxial collecting electrode. The rhodium or cobalt tubular emitting electrode contains a ductile central conducting cable placed along the longitudinal axis of the detector. The latter is in high nickel steel with a low reaction to radiation [fr

  7. Low-level radiation

    International Nuclear Information System (INIS)

    Myers, D.K.

    1982-05-01

    It is known that the normal incidence of cancer in human populations is increased by exposure to moderately high doses of ionizing radiation. At background radiation levels or at radiation levels which are 100 times greater, the potential health risks are considered to be directly proportional to the total accumulated dose of radiation. Some of the uncertainties associated with this assumption and with the accepted risk estimates have been critically reviewed in this document. The general scientific consensus at present suggests that the accepted risk estimates may exaggerate the actual risk of low levels of sparsely ionizing radiations (beta-, gamma- or X-rays) somewhat but are unlikely to overestimate the actual risks of densely ionizing radiations (fast neutrons, alpha-particles). At the maximum permissible levels of exposure for radiation workers in nuclear power stations, the potential health hazards in terms of life expectancy would be comparable to those encountered in transportation and public utilities or in the construction industry. At the average radiation exposures received by these workers in practice, the potential health hazards are similar to those associated with safe categories of industries. Uranium mining remains a relativly hazardous occupation. In terms of absolute numbers, the genetic hazards, which are less well established, are thought to be smaller than the carcinogenic hazards of radiation when only the first generation is considered but to be of the same order of magnitude as the carcinogenic hazards when the total number of induced genetic disorders is summed over all generations

  8. Radiation enteritis

    Science.gov (United States)

    Radiation enteropathy; Radiation-induced small bowel injury; Post-radiation enteritis ... Radiation therapy uses high-powered x-rays, particles, or radioactive seeds to kill cancer cells. The therapy ...

  9. Cancer incidence in atomic bomb survivors. Part IV: Comparison of cancer incidence and mortality

    International Nuclear Information System (INIS)

    Ron, E.; Preston, D.L.; Mabuchi, Kiyohiko; Thompson, D.E.; Soda, Midori

    1994-01-01

    This report compares cancer incidence and mortality among atomic bomb survivors in the Radiation Effects Research Foundation Life Span Study (LSS) cohort. Because the incidence data are derived from the Hiroshima and Nagasaki tumor registries, case ascertainment is limited to the time (1958-1987) and geographic restrictions (Hiroshima and Nagasaki) of the registries, whereas mortality data are available from 1950-1987 anywhere in Japan. With these conditions, there were 9,014 first primary incident cancer cases identified among LSS cohort members compared with 7,308 deaths for which cancer was listed as the underlying cause of death on death certificates. When deaths were limited to those occurring between 1958-1987 in Hiroshima or Nagasaki, there were 3,155 more incident cancer cases overall, and 1,262 more cancers of the digestive system. For cancers of the oral cavity and pharynx, skin, breast, female and male genital organs, urinary system and thyroid, the incidence series was at least twice as large as the comparable mortality series. Although the incidence and mortality data are dissimilar in many ways, the overall conclusions regarding which solid cancers provide evidence of a significant dose response generally confirm the mortality findings. When either incidence or mortality data are evaluated, significant excess risks are observed for all solid cancers, stomach, colon, liver (when it is defined as primary liver cancer or liver cancer not otherwise specified on the death certificate), lung, breast, ovary and urinary bladder. No significant radiation effect is seen for cancers of the pharynx, rectum, gallbladder, pancreas, nose, larynx, uterus, prostate or kidney in either series. There is evidence of a significant excess of nonmelanoma skin cancer in the incidence data, but not in the mortality series. 19 refs., 2 figs., 10 tabs

  10. Radiation biology

    International Nuclear Information System (INIS)

    Neumeister, K.

    1977-01-01

    This chapter is included in a textbook which is primarily intended for medical students. The following topics are dealt with: radiation effects on molecules; chemical and biochemical radiation effects; modification of radiation effects and radiosensitivity; radiation-induced pathomorphological and pathophysiological effects in organs and organ systems; radiation syndrome; radiation effects in embryos and fetuses; genetic radiation effects; carcinogenesis and leukemogenesis after irradiation; and radiation effects after intake of radionuclides

  11. A possibility of parallel and anti-parallel diffraction measurements on neu- tron diffractometer employing bent perfect crystal monochromator at the monochromatic focusing condition

    Science.gov (United States)

    Choi, Yong Nam; Kim, Shin Ae; Kim, Sung Kyu; Kim, Sung Baek; Lee, Chang-Hee; Mikula, Pavel

    2004-07-01

    In a conventional diffractometer having single monochromator, only one position, parallel position, is used for the diffraction experiment (i.e. detection) because the resolution property of the other one, anti-parallel position, is very poor. However, a bent perfect crystal (BPC) monochromator at monochromatic focusing condition can provide a quite flat and equal resolution property at both parallel and anti-parallel positions and thus one can have a chance to use both sides for the diffraction experiment. From the data of the FWHM and the Delta d/d measured on three diffraction geometries (symmetric, asymmetric compression and asymmetric expansion), we can conclude that the simultaneous diffraction measurement in both parallel and anti-parallel positions can be achieved.

  12. Inactivation and potential reactivation of pathogenic Escherichia coli O157:H7 in apple juice following ultraviolet light exposure at three monochromatic wavelengths.

    Science.gov (United States)

    Yin, Fugui; Zhu, Yan; Koutchma, Tatiana; Gong, Joshua

    2015-04-01

    Ultraviolet (UV) light irradiation at 254 nm is considered as a novel non-thermal method for decontamination of foodborne pathogenic bacteria. However, lower penetration depth of UV light at 254 nm in apple juice resulted in higher UV dose consumption during apple juice decontamination. In addition, no studies are available on the reactivation of pathogens following exposure to UV light in drinks and beverages. Two novel monochromatic UV light sources (λ = 222 and 282 nm) have been developed for bacterial disinfection. However, the inactivation of pathogenic Escherichia coli O157:H7 following exposure to these UV wavelengths is still unclear. Therefore, the present study was conducted to determine the inactivation and reactivation potential of pathogenic E. coli O157:H7 in apple juice following exposure to UV light at three monochromatic wavelengths: Far UV (λ = 222 nm), Far UV+ (λ = 282 nm) and UVC light (λ = 254 nm). The results showed that E. coli O157:H7 is acid-resistant, and up to 99.50% of cells survived in apple juice when incubated at 20 °C for 24 h. Inactivation of E. coli O157:H7 following exposure to Far UV light (2.81 Log reduction) was higher (P light (1.95 Log reduction) and Far UV+ light (1.83 Log reduction) at the similar levels of UV fluence of 75 mJ/cm(2). No any reactivation potential was observed for E. coli O157:H7 in dark incubation phases after exposure to UV light as determined by the regular plating method. In addition, the exposure to Far UV light at 222 nm followed by incubating at 37 °C significantly decreased (P light. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Microscopic properties of xenon plasmas for density and temperature regimes of laboratory astrophysics experiments on radiative shocks.

    Science.gov (United States)

    Rodríguez, R; Espinosa, G; Gil, J M; Stehlé, C; Suzuki-Vidal, F; Rubiano, J G; Martel, P; Mínguez, E

    2015-05-01

    This work is divided into two parts. In the first one, a study of radiative properties (such as monochromatic and the Rosseland and Planck mean opacities, monochromatic emissivities, and radiative power loss) and of the average ionization and charge state distribution of xenon plasmas in a range of plasma conditions of interest in laboratory astrophysics and extreme ultraviolet lithography is performed. We have made a particular emphasis in the analysis of the validity of the assumption of local thermodynamic equilibrium and the influence of the atomic description in the calculation of the radiative properties. Using the results obtained in this study, in the second part of the work we have analyzed a radiative shock that propagated in xenon generated in an experiment carried out at the Prague Asterix Laser System. In particular, we have addressed the effect of plasma self-absorption in the radiative precursor, the influence of the radiation emitted from the shocked shell and the plasma self-emission in the radiative precursor, the cooling time in the cooling layer, and the possibility of thermal instabilities in the postshock region.

  14. Effect of scatter on image quality in synchrotron radiation mammography

    Science.gov (United States)

    Moeckli, Raphael; Verdun, Francis R.; Fiedler, Stefan; Pachoud, Marc; Schnyder, Pierre; Valley, Jean-Francois

    2001-06-01

    The display of low-contrast structures and fine microcalcifications is essential for the early diagnosis of breast cancer. In order to achieve a high image quality level with a minimum amount of radiation delivered to the patient, the use of different spectra (Mo or Rh anode and filters) was introduced. The European Synchrotron Radiation Facility is able to produce a monochromatic beam with a high photon flux. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. Our image quality assessment is based on the calculation of the size of the smallest microcalcification detectable on a radiograph, derived from the statistical decision theory. The mean glandular dose is simultaneously measured. Compared with conventional mammography units, the monochromaticity of synchrotron beams improves contrast and the use of a slit instead of an anti-scatter grid leads to a higher primary beam transmission. The relative contribution of these two effects on image quality and dose is discussed.

  15. Development of a Standardized Method for Contouring the Lumbosacral Plexus: A Preliminary Dosimetric Analysis of this Organ at Risk Among 15 Patients Treated With Intensity-Modulated Radiotherapy for Lower Gastrointestinal Cancers and the Incidence of Radiation-Induced Lumbosacral Plexopathy

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Sun K., E-mail: sun.yi@ucdmc.ucdavis.edu [Department of Radiation Oncology, University of California, Davis Cancer Center, Sacramento, CA (United States); Mak, Walter [Department of Radiology, University of California, Davis Medical Center, Sacramento, CA (United States); Yang, Claus C.; Liu Tianxiao [Department of Radiation Oncology, University of Mississippi Medical Center, Jackson, MS (United States); Cui Jing; Chen, Allen M.; Purdy, James A.; Monjazeb, Arta M. [Department of Radiation Oncology, University of California, Davis Cancer Center, Sacramento, CA (United States); Do, Ly [Cancer Care Institute, San Jose, CA (United States)

    2012-10-01

    Purpose: To generate a reproducible step-wise guideline for the delineation of the lumbosacral plexus (LSP) on axial computed tomography (CT) planning images and to provide a preliminary dosimetric analysis on 15 representative patients with rectal or anal cancers treated with an intensity-modulated radiotherapy (IMRT) technique. Methods and Materials: A standardized method for contouring the LSP on axial CT images was devised. The LSP was referenced to identifiable anatomic structures from the L4-5 interspace to the level of the sciatic nerve. It was then contoured retrospectively on 15 patients treated with IMRT for rectal or anal cancer. No dose limitations were placed on this organ at risk during initial treatment planning. Dosimetric parameters were evaluated. The incidence of radiation-induced lumbosacral plexopathy (RILSP) was calculated. Results: Total prescribed dose to 95% of the planned target volume ranged from 50.4 to 59.4 Gy (median 54 Gy). The mean ({+-}standard deviation [SD]) LSP volume for the 15 patients was 100 {+-} 22 cm{sup 3} (range, 71-138 cm{sup 3}). The mean maximal dose to the LSP was 52.6 {+-} 3.9 Gy (range, 44.5-58.6 Gy). The mean irradiated volumes of the LSP were V40Gy = 58% {+-} 19%, V50Gy = 22% {+-} 23%, and V55Gy = 0.5% {+-} 0.9%. One patient (7%) was found to have developed RILSP at 13 months after treatment. Conclusions: The true incidence of RILSP in the literature is likely underreported and is not a toxicity commonly assessed by radiation oncologists. In our analysis the LSP commonly received doses approaching the prescribed target dose, and 1 patient developed RILSP. Identification of the LSP during IMRT planning may reduce RILSP. We have provided a reproducible method for delineation of the LSP on CT images and a preliminary dosimetric analysis for potential future dose constraints.

  16. Coherent radiation characteristics of modulated electron bunch formed in stack of two plates

    Science.gov (United States)

    Gevorgyan, H. L.; Gevorgian, L. A.

    2017-07-01

    The present article is devoted to the radiation from the electron bunch with modulated density passes through the stack consisting of two plates with different thicknesses and electrodynamic properties. The new elegant expression for the frequency-angular distribution of transition radiation is obtained. Using the existence of resonant frequency at which the longitudinal form-factor of bunch not suppresses radiation coherence and choosing parameters for the stack of plates, one can also avoid suppression of the radiation coherence by transverse form-factor of bunch. The radiation from a bunch with modulated density in the process SASE (self-amplified spontaneous emission) FEL can be partially coherent at a resonant frequency. Then the intense sub monochromatic beam of X-ray photons is formed. On the other hand one can define an important parameter of the bunch density modulation depth which is unknown to this day.

  17. General Purpose Fortran Program for Discrete-Ordinate-Method Radiative Transfer in Scattering and Emitting Layered Media: An Update of DISORT

    Science.gov (United States)

    Tsay, Si-Chee; Stamnes, Knut; Wiscombe, Warren; Laszlo, Istvan; Einaudi, Franco (Technical Monitor)

    2000-01-01

    This update reports a state-of-the-art discrete ordinate algorithm for monochromatic unpolarized radiative transfer in non-isothermal, vertically inhomogeneous, but horizontally homogeneous media. The physical processes included are Planckian thermal emission, scattering with arbitrary phase function, absorption, and surface bidirectional reflection. The system may be driven by parallel or isotropic diffuse radiation incident at the top boundary, as well as by internal thermal sources and thermal emission from the boundaries. Radiances, fluxes, and mean intensities are returned at user-specified angles and levels. DISORT has enjoyed considerable popularity in the atmospheric science and other communities since its introduction in 1988. Several new DISORT features are described in this update: intensity correction algorithms designed to compensate for the 8-M forward-peak scaling and obtain accurate intensities even in low orders of approximation; a more general surface bidirectional reflection option; and an exponential-linear approximation of the Planck function allowing more accurate solutions in the presence of large temperature gradients. DISORT has been designed to be an exemplar of good scientific software as well as a program of intrinsic utility. An extraordinary effort has been made to make it numerically well-conditioned, error-resistant, and user-friendly, and to take advantage of robust existing software tools. A thorough test suite is provided to verify the program both against published results, and for consistency where there are no published results. This careful attention to software design has been just as important in DISORT's popularity as its powerful algorithmic content.

  18. Clinical observation of radiation urinary bladder disease

    International Nuclear Information System (INIS)

    Jin Yuke; Liu Libo; Zhang Haiying; Liang Shuo; Chen Dawei; Wu Zhenfeng; Dong Lihua; Lu Xuejun

    2004-01-01

    Objective: Clinical characteristic, diagnosis and treatment of radiation urinary bladder disease induced by radiation therapy for cancers in the pelvis were inquired into for providing diagnostic basis. Methods: Statistical analysis for the clinical cases was carried out. Results: The incidence of radiation bladder diseases induced by radiation therapy of cervix cancer are about 0.8%-2.96%, with an average of 2.14%. Radiation bladder disease is divided into acute radiation cystitis, chronic radiation cystitis and radiation vesical fistula. Chronic radiation cystitis is seen most often in the clinic and its main clinical symptom is painless macroscopic hematuria, which is again subdivided into slight and severe degrees. Diagnosis should include history of exposure to radiation, which dose exceed the dose threshold, and typical clinical characteristics. Conclusion: The characteristics, types and diagnostic basis of radiation urinary bladder disease analyzed in this study can provide the reference for drawing up diagnostic standard

  19. Incidents with materials (natural radioactive materials) in Saxony; Vorkommnisse mit Materialien (radioaktive Stoffe natuerlichen Ursprungs) im Freistaat Sachsen

    Energy Technology Data Exchange (ETDEWEB)

    Flesch, Klaus [Saechsisches Landesamt fuer Umwelt, Landwirtschaft und Geologie, Dresden (Germany). Strahlenschutz; Philipp, Thomas [Saechsisches Landesamt fuer Umwelt, Landwirtschaft und Geologie, Dresden-Pillnitz (Germany). Strahlenschutz

    2017-04-01

    In Saxony materials with unknown origin have to be registered and tested with mobile or stationary radiation monitoring facilities and classified according the radiation protection regulations. Experiences with respective incidents are discussed in the contribution.

  20. Near-ultraviolet radiation blocks SOS responses to DNA damage in Escherichia coli

    Energy Technology Data Exchange (ETDEWEB)

    Turner, M.A.; Eisenstark, A.

    1984-01-01

    Escherichia coli cells in which the recA promoter is fused to a lac structural gene, (Mu) Mud(Ap,lac)::rec, were irradiated with two far-ultraviolet light wavelengths (254 and 290 nm), selected monochromatic near-ultraviolet (NUV) wavelengths 313 nm, 334 nm, 365 nm, or broad band solar-UV (290-420 nm) from a solar simulator. Irradiation with the two far-ultraviolet wavelengths was followed by high yields of ..beta..-galactosidase, lambda prophage induction, and Weigle reactivation. These end points were not observed after irradiation with the selected NUV wavelengths or the broad spectrum solar-UV. Thus, neither broad spectrum solar-UV nor monochromatic NUV wavelengths resulted in the derepression of the recA promoter. Further, prior exposure of the cells either to the selected monochromatic NUV wavelengths or to solar-UV inhibited a) the induction of ..beta..-galactosidase by subsequent 254-nm radiation, b) subsequent 254-nm induction of lambda prophage, c) Weigle reactivation, and d) mutation frequency. These observations are consistent with the hypothesis that NUV blocks subsequent recA protease action.

  1. Measurement of the radiative vacancy transfer probabilities from the $L_{3}$ to M and to N shells for W, Re and Pb using synchrotron radiation

    CERN Document Server

    Bonzi, E V

    2006-01-01

    The radiative vacancy transfer probabilities from L/sub 3/ to M shell, eta/sub L3/M(R) and L/sub 3/ to N shell, eta/sub L3/N(R), have been determined for W, Re and Pb. The pure elements samples were excited by monochromatic synchrotron radiation. The X-rays were generated by excitation of L/sub 3/ edge and measured using a high resolution Si(Li) detector. The experimentally determined radiative vacancy transfer probabilities were compared with the theoretical values deduced using radiative X-ray emission rates based on the relativistic Dirac-Hartree-Slater (RDHS) model. In the case of Pb, the experimental data were compared as well with experimental values of Simsek. In both cases, a good agreement was found between the datasets.

  2. Incidents in nuclear installations

    International Nuclear Information System (INIS)

    Franzen, L.F.; Wienhold, W.

    1976-09-01

    With reference to the incident list of the Ministry for the period 1971-74, Prof. Bechert has expressed a lot of questions and statements in a letter to the Government. The letter is quoted in full. Inadequate conclusions drawn by Prof. Bechert in connection with quotations from daily newspapers and other documents are put right. (HP) [de

  3. Lightning incidents in Mongolia

    Directory of Open Access Journals (Sweden)

    Myagmar Doljinsuren

    2015-11-01

    Full Text Available This is one of the first studies that has been conducted in Mongolia on the distribution of lightning incidents. The study covers a 10-year period from 2004 to 2013. The country records a human death rate of 15.4 deaths per 10 million people per year, which is much higher than that of many countries with similar isokeraunic level. The reason may be the low-grown vegetation observed in most rural areas of Mongolia, a surface topography, typical to steppe climate. We suggest modifications to Gomes–Kadir equation for such countries, as it predicts a much lower annual death rate for Mongolia. The lightning incidents spread over the period from May to August with the peak of the number of incidents occurring in July. The worst lightning affected region in the country is the central part. Compared with impacts of other convective disasters such as squalls, thunderstorms and hail, lightning stands as the second highest in the number of incidents, human deaths and animal deaths. Economic losses due to lightning is only about 1% of the total losses due to the four extreme weather phenomena. However, unless precautionary measures are not promoted among the public, this figure of losses may significantly increase with time as the country is undergoing rapid industrialization at present.

  4. Fire Incident Reporting Manual

    Science.gov (United States)

    1984-02-01

    the result of an incident that requires (or should require) treatment by a practitioner of medicine , a registered emergency medical technician, or a...UNANNOUNCED AIRCRAFT EMERGENCYS ~~PRIOR TO TAKE OFF OR AFTERLADN 5 FUEL OPERATIONS REQUIRING 1AREING G A FIRE10 ARRESTING GEAR’BARRIER FR . ENGAGEMENTS AND

  5. Radiation emitter-detector package

    International Nuclear Information System (INIS)

    O'Brien, J.T.; Limm, A.C.; Nyul, P.; Tassia, V.S. Jr.

    1978-01-01

    Mounted on the metallic base of a radiation emitter-detector is a mounting block is a first projection, and a second projection. A radiation detector is on the first projection and a semiconductor electroluminescent device, i.e., a radiation emitter, is on the second projection such that the plane of the recombination region of the electroluminescent device is perpendicular to the radiation incident surface of the radiation detector. The electroluminescent device has a primary emission and a secondary emission in a direction different from the primary emission. A radiation emitter-detector package as described is ideally suited to those applications wherein the secondary radiation of the electroluminescent device is fed into a feedback circuit regulating the biasing current of the electroluminescent device

  6. Incidence Probability of Delayed Health Consequences of the Chernobyl Accident

    International Nuclear Information System (INIS)

    Abdel-Ghani, A.H.; El-Naggar, A.M.; El-Kadi, A.A.

    2000-01-01

    During the first international Conference on the long -term consequences of the Chernobyl disaster in 1995 at Kiev, and also during the 1996 International Conference at Vienna, Summing up the consequences of the Chernobyl accident, the data regarding the delayed health consequences were mainly related to thyroid cancer, hereditary disorders, general morbidity, mortality and psychological disturbances. Contrary to expectations, the incidences of Leukemia and Soft Tissue tumors were similar to the spontaneous incident. The expected delayed effects, however, among the accident survivors, the liquidators and populations resident in contaminated areas would show higher incidence probability to Leukemia. These population groups have been continuously exposed to low level radiation both externally and internally. Application of the new ICRP concept of radiation-induced Detriment, and the Nominal Probability Coefficient for Cancer and hereditary effects for both workers and populations are used as the rationale to calculate the incidence probability of occurrence of delayed health effects of the Chernobyl accidents

  7. Comparação de produtos de radiação solar incidente à superfície para a América do Sul Product comparison of solar radiation incident surface for South America

    Directory of Open Access Journals (Sweden)

    Lucía Iracema Chipponelli Pinto

    2010-12-01

    Full Text Available Para algumas aplicações meteorológicas, o conhecimento da radiação solar incidente à superfície (Sin é muito importante. Métodos convencionais de medida deste fluxo são pontuais e, portanto, representativos de pequenas áreas. Por outro lado, os satélites meteorológicos possibilitam uma cobertura regular de todo o globo terrestre, proporcionando estimativas de fluxos radiativos sobre grandes áreas com resolução espacial do sensor (apenas alguns quilômetros. Além disso, produtos de reanálise fornecem estimativas alternativas de Sin, que precisam ser adequadamente validadas. Este trabalho compara quatro bancos de dados de radiação solar incidente para a América do Sul: três produtos provenientes de reanálise (NCEP/NCAR, ERA-40 e Eta/CPTEC e o produto gerado pelo algoritmo GL1.2, que produz estimativas da Sin a partir do conjunto de imagens do satélite GOES. Os resultados mostram que os campos de radiação solar incidente dos produtos de reanálise do NCEP/NCAR, ERA-40 e as estimativas do satélite GOES apresentam valores médios mensais bem próximos para todos os biomas e bacias estudados. Já a reanálise do Eta/CPTEC apresentou valores bem mais elevados para à radiação sobre a América do Sul, tanto para a média anual como nas médias mensais analisadas.For some meteorological applications, knowledge of incoming solar radiation at surface level (Sin is very important. Conventional measurements of this flux by individual sensors are representative of small areas only. On the other hand, meteorological satellites allow a regular cover of the entire globe, providing estimates of radiative fluxes over wide areas, within the spatial resolution of the sensor (a few km. In addition, reanalysis products provide alternative Sin estimates that must be adequately validated. This work compares four long-term Sin databases for South America: three reanalysis products (NCEP/NCAR, ERA-40 e Eta/CPTEC and the database produced by

  8. Rating of transport and radiation source events. Draft additional guidance for the INES national officers for pilot use and feedback; Echelle de classement des incidents de radioprotection: document d'application du systeme international propose par l'AIEA pour les sources radioactives et les transports

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-09-15

    The International Nuclear Event Scale (INES) is a means for promptly communicating to the public in consistent terms the safety significance of any reported event associated with radioactive material and/or radiation and to any event occurring during the transport of radioactive material. As described in the 2001 Edition of the INES User.s Manual, events are classified on the scale at seven levels: the upper levels (4-7) are termed accidents. and the lower levels (1-3) incidents. Events which have no safety significance are classified below scale at Level 0 and termed deviations. An overview of the principles for the rating under INES together with flow charts summarizing the rating process is provided in Appendix I. The 2001 Edition of the INES User.s Manual provides some guidance for the rating of transport and radiation source events. At the technical meeting held in 2002 the INES National Officers requested the IAEA/NEA Secretariat to prepare additional guidance. Progress was reported at the Technical Meeting of the INES National Officers in March 2004 where preparation of this draft additional guidance was requested for pilot use. This note provides additional guidance on the rating of transport and radiation source events. It is for pilot use and feedback and is broadly consistent with the INES User.s Manual. It provides more detailed information and an expanded approach for the rating based on actual exposure of workers and members of the public. It is designed to be used as a self-standing document with limited need for reference to the INES User Manual. (author)

  9. Risk management of radiation therapy. Survey by north Japan radiation therapy oncology group

    International Nuclear Information System (INIS)

    Aoki, Masahiko; Abe, Yoshinao; Yamada, Shogo; Hareyama, Masato; Nakamura, Ryuji; Sugita, Tadashi; Miyano, Takashi

    2004-01-01

    A North Japan Radiation Oncology Group (NJRTOG) survey was carried out to disclose the risk management of radiation therapy. During April 2002, we sent questionnaires to radiation therapy facilities in northern Japan. There were 31 replies from 27 facilities. Many incidents and accidents were reported, including old cases. Although 60% of facilities had a risk management manual and/or risk manager, only 20% had risk management manuals for radiation therapy. Eighty five percent of radiation oncologists thought that incidents may be due to a lack of manpower. Ninety percent of radiation oncologists want to know the type of cases happened in other facilities. The risk management system is still insufficient for radiation therapy. We hope that our data will be a great help to develop risk management strategies for radiation therapy for all radiation oncologists in Japan. (author)

  10. Chromosome aberrations in Japanese fishermen exposed to fallout radiation 420-1200 km distant from the nuclear explosion test site at Bikini Atoll: report 60 years after the incident

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Kimio [Hiroshima University, Research Institute for Radiation Biology and Medicine, Hiroshima City, Hiroshima (Japan); Institute for Environmental Sciences, Kakimita, Aomori (Japan); Ohtaki, Megu; Hoshi, Masaharu [Hiroshima University, Research Institute for Radiation Biology and Medicine, Hiroshima City, Hiroshima (Japan)

    2016-08-15

    During the period from March to May, 1954, the USA conducted six nuclear weapon tests at the ''Bravo'' detonation sites at the Bikini and Enewetak Atolls, Marshall Islands. At that time, the crew of tuna fishing boats and cargo ships that were operating approximately 150-1200 km away from the test sites were exposed to radioactive fallout. The crew of the fishing boats and those on cargo ships except the ''5th Fukuryu-maru'' did not undergo any health examinations at the time of the incident. In the present study, chromosome aberrations in peripheral blood lymphocytes were examined in detail by the G-banding method in 17 crew members from 8 fishing boats and 2 from one cargo ship, 60 years after the tests. None of the subjects examined had suffered from cancer. The percentages of both stable-type aberrations such as translocation, inversion and deletion, and unstable-type aberrations such as dicentric and centric ring in the study group were significantly higher (1.4- and 2.3-fold, respectively) than those in nine age-matched controls. In the exposed and control groups, the percentages of stable-type aberrations were 3.35 % and 2.45 %, respectively, and the numbers of dicentric and centric ring chromosomes per 100 cells were 0.35 and 0.15, respectively. Small clones were observed in three members of the exposed group. These results suggest that the crews were exposed to slightly higher levels of fallout than had hitherto been assumed. (orig.)

  11. Chromosome aberrations in Japanese fishermen exposed to fallout radiation 420-1200 km distant from the nuclear explosion test site at Bikini Atoll: report 60 years after the incident.

    Science.gov (United States)

    Tanaka, Kimio; Ohtaki, Megu; Hoshi, Masaharu

    2016-08-01

    During the period from March to May, 1954, the USA conducted six nuclear weapon tests at the "Bravo" detonation sites at the Bikini and Enewetak Atolls, Marshall Islands. At that time, the crew of tuna fishing boats and cargo ships that were operating approximately 150-1200 km away from the test sites were exposed to radioactive fallout. The crew of the fishing boats and those on cargo ships except the "5th Fukuryu-maru" did not undergo any health examinations at the time of the incident. In the present study, chromosome aberrations in peripheral blood lymphocytes were examined in detail by the G-banding method in 17 crew members from 8 fishing boats and 2 from one cargo ship, 60 years after the tests. None of the subjects examined had suffered from cancer. The percentages of both stable-type aberrations such as translocation, inversion and deletion, and unstable-type aberrations such as dicentric and centric ring in the study group were significantly higher (1.4- and 2.3-fold, respectively) than those in nine age-matched controls. In the exposed and control groups, the percentages of stable-type aberrations were 3.35 % and 2.45 %, respectively, and the numbers of dicentric and centric ring chromosomes per 100 cells were 0.35 and 0.15, respectively. Small clones were observed in three members of the exposed group. These results suggest that the crews were exposed to slightly higher levels of fallout than had hitherto been assumed.

  12. Chernobyl fallout and cancer incidence in Finland.

    Science.gov (United States)

    Auvinen, Anssi; Seppä, Karri; Pasanen, Kari; Kurttio, Päivi; Patama, Toni; Pukkala, Eero; Heinävaara, Sirpa; Arvela, Hannu; Verkasalo, Pia; Hakulinen, Timo

    2014-05-01

    Twenty-five years have passed since the Chernobyl accident, but its health consequences remain to be well established. Finland was one of the most heavily affected countries by the radioactive fallout outside the former Soviet Union. We analyzed the relation of the estimated external radiation exposure from the fallout to cancer incidence in Finland in 1988-2007. The study cohort comprised all ∼ 3.8 million Finns who had lived in the same dwelling for 12 months following the accident (May 1986-April 1987). Radiation exposure was estimated using data from an extensive mobile dose rate survey. Cancer incidence data were obtained for the cohort divided into four exposure categories (the lowest with the first-year committed dose fallout [excess rate ratio per increment in exposure category 0.06, 95% confidence interval (CI) 0.02-0.11]. No such effect was observed for men, or other cancer sites. Our analysis of a large cohort over two decades did not reveal an increase in cancer incidence following the Chernobyl accident, with the possible exception of colon cancer among women. The largely null findings are consistent with extrapolation from previous studies suggesting that the effect is likely to remain too small to be empirically detectable and of little public health impact.

  13. Proceedings of the symposium on molecular biology and radiation protection

    International Nuclear Information System (INIS)

    Marko, A.M.

    1996-02-01

    The symposium on molecular biology and radiation protection was organized in sessions with the following titles: Radiation protection and the human genome; Molecular changes in DNA induced by radiation; Incidence of genetic changes - pre-existing, spontaneous and radiation-induced; Research directions and ethical implications. The ten papers in the symposium have been abstracted individually

  14. Spatio-temporal coherence of free-electron laser radiation in the extreme ultraviolet determined by a Michelson interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Hilbert, V.; Rödel, C.; Zastrau, U., E-mail: ulf.zastrau@uni-jena.de [Institut für Optik und Quantenelektronik, Friedrich-Schiller-Universität, Max-Wien-Platz 1, 07743 Jena (Germany); Brenner, G.; Düsterer, S.; Dziarzhytski, S.; Harmand, M.; Przystawik, A.; Redlin, H.; Toleikis, S. [Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg (Germany); Döppner, T.; Ma, T. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States); Fletcher, L. [Department of Physics, University of California, Berkeley, California 94720 (United States); Förster, E. [Institut für Optik und Quantenelektronik, Friedrich-Schiller-Universität, Max-Wien-Platz 1, 07743 Jena (Germany); Helmholtz-Institut Jena, Fröbelstieg 3, 07743 Jena (Germany); Glenzer, S. H.; Lee, H. J. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Hartley, N. J. [Department of Physics, Clarendon Laboratory, University of Oxford, Parks Road, Oxford OX1 3PU (United Kingdom); Kazak, L.; Komar, D.; Skruszewicz, S. [Institut für Physik, Universität Rostock, 18051 Rostock (Germany); and others

    2014-09-08

    A key feature of extreme ultraviolet (XUV) radiation from free-electron lasers (FELs) is its spatial and temporal coherence. We measured the spatio-temporal coherence properties of monochromatized FEL pulses at 13.5 nm using a Michelson interferometer. A temporal coherence time of (59±8) fs has been determined, which is in good agreement with the spectral bandwidth given by the monochromator. Moreover, the spatial coherence in vertical direction amounts to about 15% of the beam diameter and about 12% in horizontal direction. The feasibility of measuring spatio-temporal coherence properties of XUV FEL radiation using interferometric techniques advances machine operation and experimental studies significantly.

  15. Asymmetric-cut variable-incident-angle monochromator.

    Science.gov (United States)

    Smither, R K; Graber, T J; Fernandez, P B; Mills, D M

    2012-03-01

    A novel asymmetric-cut variable-incident-angle monochromator was constructed and tested in 1997 at the Advanced Photon Source of Argonne National Laboratory. The monochromator was originally designed as a high heat load monochromator capable of handling 5-10 kW beams from a wiggler source. This was accomplished by spreading the x-ray beam out on the surface an asymmetric-cut crystal and by using liquid metal cooling of the first crystal. The monochromator turned out to be a highly versatile monochromator that could perform many different types of experiments. The monochromator consisted of two 18° asymmetrically cut Si crystals that could be rotated about 3 independent axes. The first stage (Φ) rotates the crystal around an axis perpendicular to the diffraction plane. This rotation changes the angle of the incident beam with the surface of the crystal without changing the Bragg angle. The second rotation (Ψ) is perpendicular to the first and is used to control the shape of the beam footprint on the crystal. The third rotation (Θ) controls the Bragg angle. Besides the high heat load application, the use of asymmetrically cut crystals allows one to increase or decrease the acceptance angle for crystal diffraction of a monochromatic x-ray beam and allows one to increase or decrease the wavelength bandwidth of the diffraction of a continuum source like a bending-magnet beam or a normal x-ray-tube source. When the monochromator is used in the doubly expanding mode, it is possible to expand the vertical size of the double-diffracted beam by a factor of 10-15. When this was combined with a bending magnet source, it was possible to generate an 8 keV area beam, 16 mm wide by 26 mm high with a uniform intensity and parallel to 1.2 arc sec that could be applied in imaging experiments.

  16. Results of the implementation of a learning system with incidents in an radiotherapy department

    International Nuclear Information System (INIS)

    Radicchi, Lucas Augusto; Vilela, Ellen Pedroso Severino; Faustino, Fabio de Lima C.; Rodrigues, Fernanda Arantes C.; Gomes, Franciele N.; Souza, Guilherme Vicente de; Silva, Rose Marta S.; Toledo, Jose Carlos de

    2016-01-01

    An incident learning system (ILS) is an important tool for improving aspects of patient and staff safety. In radiation oncology, ILS has been implemented both at the institutional level as at the national level, allowing to share lessons learned from incidents that have already occurred. The objective of this study is to present the preliminary results of the ILS implemented in a radiation oncology department. In total, 128 incidents were reviewed by a multidisciplinary committee, and the professional groups that registered more were medical physicists, radiation oncologists and radiation therapists. In addition, incidents have occurred and have been detected mainly in the treatment step. The incident learning system proved to be an important process improvement tool, according to the results shown,the improvement actions proposed and the perception of the people involved. (author)

  17. Radiation practices. Annual report 2008

    International Nuclear Information System (INIS)

    Rantanen, E.

    2009-09-01

    1775 safety licences for the use of radiation were current at the end of 2008. 1831 responsible parties were engaged in notifiable licence-exempt dental X-ray activities. Use of radiation was controlled through regular inspections performed at places of use, test packages sent by post to dental X-ray facilities and maintenance of the Dose Register. Radiation safety guides were also published and research was conducted in support of regulatory control. STUK conducted 424 inspections of licensed practices and 18 inspections of notifiable licence-exempt dental X-ray practices in 2008. 209 repair orders and recommendations were issued. Use of one appliance was prohibited. A total of just over 11 500 workers were subject to individual monitoring in 2008, and about 140 000 dose entries were made in the Dose Register maintained by STUK. Regulatory control of natural radiation focused on radon at workplaces and exposure of aircrews to cosmic radiation. 89 workplaces including a total of 201 work areas were subject to radon monitoring during 2008. Some 3700 pilots and cabin crew members were monitored for exposure to cosmic radiation. Metrological activities continued with calibration and development work as in previous years. Regulatory control of the use of non-ionizing radiation in 2008 focused particularly on mobile phones, sunbeds and lasers. Ten mobile phone types and five baby monitors were tested in market surveillance of wireless communication devices. 25 sunbed facilities were inspected and nine laser display inspections were performed. There were 22 abnormal incidents involving the use of radiation in 2008. Seventeen of these incidents concerned the use of radiation in industry, research or transportation, four concerned the use of radiation in health care, and one concerned the use of non-ionizing radiation. None of these incidents had serious consequences. (orig.)

  18. Radiation monitor

    International Nuclear Information System (INIS)

    Pao, C.T.; Green, W.K.

    1978-01-01

    A system for indicating radiation from a radioactive fluid such as a gas wherein simultaneous indications of the activity concentration of radioactivity of the gas, the radiation dose rate and average energy of the radiation are provided

  19. Radiation protection

    International Nuclear Information System (INIS)

    Ures Pantazi, M.

    1994-01-01

    This work define procedures and controls about ionizing radiations. Between some definitions it found the following topics: radiation dose, risk, biological effects, international radioprotection bodies, workers exposure, accidental exposure, emergencies and radiation protection

  20. Grazing incidence optics; Proceedings of the Meeting, Orlando, FL, Apr. 3, 4, 1986

    Science.gov (United States)

    Osantowski, John F. (Editor); Van Speybroeck, Leon (Editor)

    1986-01-01

    Papers are presented on the diffraction-limited performance of grazing incidence optical systems; transverse ray aberrations of Wolter type 1 telescopes; hybrid X-ray telescope systems; surface characterization of grazing incidence optics in the extreme UV and X-ray regions; and the surface roughness properties of synchrotron radiation optics. Topics discussed include the simulation of free-abrasive grinding of grazing incidence mirrors with vertical-honing and flexible blades; mirrors for the Extreme Ultraviolet Explorer; the design and development of conical X-ray imaging mirrors; thermal loading considerations for synchrotron radiation mirrors; and grazing incidence optics for synchrotron radiation insertion-device beams. Consideration is given to the interpretation of glancing incidence scattering measurements; damage processes in short wavelength coated FEL optics; the replication of grain incidence optics; and the assembly and alignment of the Technology Mirror Assembly.

  1. Radiation-induced enteropathy

    Energy Technology Data Exchange (ETDEWEB)

    Sher, M.E.; Bauer, J. (Mount Sinai Hospital, New York, NY (USA))

    1990-02-01

    The incidence of chronic radiation enteritis appears to have risen in recent years due to the increasing utilization of radiotherapy for abdominal and pelvic malignancies. The etiology, pathogenesis, and management of radiation enteritis are discussed. Two case reports exemplify the progressive nature of the disease. Case 1 demonstrates the classical picture of multiple exacerbations and remissions of partial small bowel obstruction and the eventual need for surgical management ten years after radiation therapy. Case 2 presents the more severe sequelae of an acute perforation with a 14-yr latency period. Predisposing factors in the progression of radiation injury include excessive radiation, underlying cardiovascular disease, fixation of the bowel, and an asthenic habitus. In both cases, radiation injury was localized to a discrete segment of bowel; therefore, resection with a primary end-to-end anastomosis was performed. In addition, diseased bowel was eliminated and, therefore, would not cause further complications such as intractable bleeding or fistula formation. The review focuses on current knowledge which may be applied to the treatment and prevention of radiation enteritis.

  2. Constipation and Incident CKD.

    Science.gov (United States)

    Sumida, Keiichi; Molnar, Miklos Z; Potukuchi, Praveen K; Thomas, Fridtjof; Lu, Jun Ling; Matsushita, Kunihiro; Yamagata, Kunihiro; Kalantar-Zadeh, Kamyar; Kovesdy, Csaba P

    2017-04-01

    Constipation is one of the most prevalent conditions in primary care settings and increases the risk of cardiovascular disease, potentially through processes mediated by altered gut microbiota. However, little is known about the association of constipation with CKD. In a nationwide cohort of 3,504,732 United States veterans with an eGFR ≥60 ml/min per 1.73 m 2 , we examined the association of constipation status and severity (absent, mild, or moderate/severe), defined using diagnostic codes and laxative use, with incident CKD, incident ESRD, and change in eGFR in Cox models (for time-to-event analyses) and multinomial logistic regression models (for change in eGFR). Among patients, the mean (SD) age was 60.0 (14.1) years old; 93.2% of patients were men, and 24.7% were diabetic. After multivariable adjustments, compared with patients without constipation, patients with constipation had higher incidence rates of CKD (hazard ratio, 1.13; 95% confidence interval [95% CI], 1.11 to 1.14) and ESRD (hazard ratio, 1.09; 95% CI, 1.01 to 1.18) and faster eGFR decline (multinomial odds ratios for eGFR slope constipation associated with an incrementally higher risk for each renal outcome. In conclusion, constipation status and severity associate with higher risk of incident CKD and ESRD and with progressive eGFR decline, independent of known risk factors. Further studies should elucidate the underlying mechanisms. Copyright © 2017 by the American Society of Nephrology.

  3. Cancer incidence among firefighters

    DEFF Research Database (Denmark)

    Pukkala, Eero; Martinsen, Jan Ivar; Weiderpass, Elisabete

    2014-01-01

    .51), adenocarcinoma of the lung (SIR=1.90, 95% CI 1.34 to 2.62), and mesothelioma (SIR=2.59, 95% CI 1.24 to 4.77). By contrast with earlier studies, the incidence of testicular cancer was decreased (SIR=0.51, 95% CI 0.23 to 0.98). CONCLUSIONS: Some of these associations have been observed previously, and potential...

  4. Effect of contamination on gynecological disease incidence in women

    International Nuclear Information System (INIS)

    Agamova, K.A.; Sotnikova, E.N.; Gladunova, Z.D.; Novikova, E.G.; Aleksandrova, L.M.

    1995-01-01

    Epithelial tissues of neck of the womb, cervical canal and endometritis in women residing on the territories with increased radiation background after the Chernobyl accident have been examined. The cytologic diagnosis method employed demonstrated a high information content. Incidence of background, precancer and inflammatory processes has been ascertained in compliance with cytological classification. Cytomorphological signs of possible radiation-induced injury of cells have been studied

  5. Cancer incidence among waiters

    DEFF Research Database (Denmark)

    Reijula, Jere; Kjaerheim, Kristina; Lynge, Elsebeth

    2015-01-01

    AIMS: To study cancer risk patterns among waiters in the Nordic countries. METHODS: We identified a cohort of 16,134 male and 81,838 female waiters from Denmark, Finland, Iceland, Norway and Sweden. During the follow-up period from 1961 to 2005, we found that 19,388 incident cancer cases were...... diagnosed. Standardised incidence ratio (SIR) was defined as the observed number of cancer cases divided by the expected number, based on national age, time period and gender-specific cancer incidence rates in the general population. RESULTS: The SIR of all cancers in waiters, in the five countries combined......, was 1.46 (95% CI 1.41-1.51) in men and 1.09 (1.07-1.11) in women. In male waiters, the SIR decreased from 1.79 (1.63-1.96) in 1961-1975, to 1.33 (1.26-1.40) in 1991-2005, but remained stable among women. The SIR among male waiters was highest for cancers in the pharynx (6.11; 95% CI 5.02-7.37), oral...

  6. Ionizing radiation

    International Nuclear Information System (INIS)

    Kruger, J.

    1989-01-01

    Ionizing radiation results in biological damage that differs from other hazardous substances and is highly dangerous to man. Ionizing radiation cannot be perceived by man's sense organs and the biological damage cannot be detected immediately afterwards (except in very high doses). Every human being is exposed to low doses of radiation. The structure of the atom; sources of ionizing radiation; radiation units; biological effects; norms for radiation protection; and the national control in South Africa are discussed. 1 fig., 5 refs

  7. Radiation dosimetry

    CERN Document Server

    Hine, Gerald J; Hine, Gerald J

    1956-01-01

    Radiation Dosimetry focuses on the advancements, processes, technologies, techniques, and principles involved in radiation dosimetry, including counters and calibration and standardization techniques. The selection first offers information on radiation units and the theory of ionization dosimetry and interaction of radiation with matter. Topics include quantities derivable from roentgens, determination of dose in roentgens, ionization dosimetry of high-energy photons and corpuscular radiations, and heavy charged particles. The text then examines the biological and medical effects of radiation,

  8. Radiation induced liver disease: A clinical update

    International Nuclear Information System (INIS)

    Benson, R.; Madan, R.; Chander, S.; Kilambi, R.

    2016-01-01

    Radiation-induced liver disease (RILD) or radiation hepatitis is a sub-acute form of liver injury due to radiation. It is one of the most dreaded complications of radiation which prevents radiation dose escalation and re irradiation for hepatobiliary or upper gastrointestinal malignancies. This complication should be kept in mind whenever a patient is planned for irradiation of these malignancies. Although, incidence of RILD is decreasing due to better knowledge of liver tolerance, improved investigation modalities and modern radiation delivery techniques, treatment options are still limited. In this review article, we have focussed on pathophysiology, risk factors, prevention and management of RILD

  9. Safety-related incidents at the Finnish nuclear power plants

    International Nuclear Information System (INIS)

    Lehtinen, P.

    1985-01-01

    This report contains detailed descriptions of operating incidents and other safety-related matters at the Finnish nuclear power plants regarded as significant by the regulatory authority, the Finnish Centre for Radiation and Nuclear Safety. In this connection, an account is given of the practical actions caused by the incidents, and their significance to reactor safety is evaluated. The main features of the incidents are also described in the general Quartely Reports, Operation of Finnish Nuclear Power Plants, which are supplemented by this report intended for experts. (author)

  10. Incidence of fruit flies on coffee and citrus and quarantine treatment of citrus fruits by gamma radiation; Incidencia de moscas-das-frutas em cafe e citros e tratamento quarentenario de frutos citricos com radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Raga, Adalton

    1996-12-31

    The objective of this study was to evaluate the fruit fly infestation on coffee and citrus, and also to determine gamma radiation doses for immature stages of Ceratitis capitata and Anastrepha fraterculus, in order to satisfy quarantine regulations. Coffee arabica varieties Icatu Vermelho, Catuai Amarelo, Mundo Novo and Sarchimor showed the highest infestation indices (pupa/berry): 0.53; 0,41; 0.33 and 0.36. respectively Icatu Vermelho and Catuai Vermelho showed the highest values of pupa/berry weight (0.49 and 0.39, respectively), and Robusta (Coffea canephora) presented the lowest index (0.01). The following fruit flies were found in coffee berries: C. capitata (76.6%) Anastrepha spp. (7.4%) and Lonchaeidae (17.0%). In area near coffee plantation, fruit fly infestation indices in sweet oranges were of 4.77 larvae/kg and 0.55 larva/fruit. The infestation indices for sweet orange, collected from five regions of the State of Sao Paulo ranged from 0.73 to 7.60 pupa/kg and 0.12 to 1.27 pupa/fruit. The same species of fruit flies were found in oranges. In the case of C. capitata eggs with 24-48 hours old, 20 Gy prevented completely adult emergence (artificial diet and orange). No emergence of adult occurred when C. capitata larvae of third instar were irradiated at 20 Gy in their rearing medium. But at 25 Gy, the number of adults was reduced by 54% and 97% from larval infestation in oranges and grapefruit, respectively. A dose of 30 Gy was required to prevent medfly emergence from third instar larvae in grapefruit. A dose of 15 Gy was required for third instar, to prevent adult emergence of A. fraterculus. No adult emerged from C third instar, to prevent adult emergence of A. fraterculus. No adult emerged from C capitata pre-pupa irradiated at 30 Gy. One medfly adult emerged from pupa (3-4 days after pupating) irradiated at 120 Gy. At the same dose, sixteen A. fraterculus adults emergency from irradiated pupa with 5-6 days old. (author) 85 refs., 2 figs., 13 tabs.

  11. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    International Nuclear Information System (INIS)

    Troussel, Ph.; Dennetiere, D.; Maroni, R.; Høghøj, P.; Hedacq, S.; Cibik, L.; Krumrey, M.

    2014-01-01

    The “Commissariat à l’énergie atomique et aux énergies alternatives” (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin

  12. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    Energy Technology Data Exchange (ETDEWEB)

    Troussel, Ph., E-mail: philippe.troussel@cea.fr [CEA, DAM, DIF, F-91297 Arpajon (France); Dennetiere, D. [Synchrotron Soleil, L’orme des Merisiers, 91190 Saint-Aubin (France); Maroni, R. [CEA, DAM, DIF, F-91297 Arpajon (France); Høghøj, P.; Hedacq, S. [Xenocs SA, 19, rue François Blumet, F-38360 Sassenage (France); Cibik, L.; Krumrey, M. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany)

    2014-12-11

    The “Commissariat à l’énergie atomique et aux énergies alternatives” (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin.

  13. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    Science.gov (United States)

    Troussel, Ph.; Dennetiere, D.; Maroni, R.; Høghøj, P.; Hedacq, S.; Cibik, L.; Krumrey, M.

    2014-12-01

    The "Commissariat à l'énergie atomique et aux énergies alternatives" (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin.

  14. Health effects of radiation and the implications for radiation safety

    International Nuclear Information System (INIS)

    Gonzalez, A.J.; Anderer, J.

    1991-01-01

    In this Paper two elements of a multiphase analysis of radiation exposures in the living environment - the human health effects of ionizing radiation and the implications for radiation safety policy and practices - are presented. Part 1 draws together the current state of scientific knowledge and insight about the human health effects of radiation, describing these in terms of known cause-related deterministic effects and of the estimated incidence of stochastic effects as defined by biostatistics and biological models. The 1988 UNSCEAR report provides an authoritative basis for such an examination. Part 2 explores some of the major implications that the state-of-the-art of radiation biology has - or should have - for radiation safety policy and practices. (author)

  15. Significant incidents in nuclear fuel cycle facilities

    International Nuclear Information System (INIS)

    1996-03-01

    In contrast to nuclear power plants, events in nuclear fuel cycle facilities are not well documented. The INES database covers all the nuclear fuel cycle facilities; however, it was developed in the early 1990s and does not contain information on events prior to that. The purpose of the present report is to collect significant events and analyze them in order to give a safety related overview of nuclear fuel cycle facilities. Significant incidents were selected using the following criteria: release of radioactive material or exposure to radiation; degradation of items important to safety; and deficiencies in design, quality assurance, etc. which include criticality incidents, fire, explosion, radioactive release and contamination. This report includes an explanation, where possible, of root causes, lessons learned and action taken. 4 refs, 4 tabs

  16. Radiation, accidents, society

    International Nuclear Information System (INIS)

    1988-01-01

    This book is meant to be used as a reference book for information officers at the event of a nuclear accident. The main part is edited in alphabetical order to facilitate use under stress. The book gives a short review of the health risks of radiation, and descriptions of accidents that have occured. The index words that have been chosen for the main part of the book have been selected due to experiences in connection with incidents and accidents. (L.E.)

  17. Medication incidents reported to an online incident reporting system.

    LENUS (Irish Health Repository)

    Alrwisan, Adel

    2011-01-15

    AIMS: Approximately 20% of deaths from adverse events are related to medication incidents, costing the NHS an additional £500 million annually. Less than 5% of adverse events are reported. This study aims to assess the reporting rate of medication incidents in NHS facilities in the north east of Scotland, and to describe the types and outcomes of reported incidents among different services. Furthermore, we wished to quantify the proportion of reported incidents according to the reporters\\' profession. METHODS: A retrospective description was made of medication incidents reported to an online reporting system (DATIX) over a 46-month-period (July 2005 to April 2009). Reports originated from acute and community hospitals, mental health, and primary care facilities. RESULTS: Over the study period there were 2,666 incidents reported with a mean monthly reporting rate of 78.2\\/month (SD±16.9). 6.1% of all incidents resulted in harm, with insulin being the most commonly implicated medication. Nearly three-quarters (74.2%, n=1,978) of total incidents originated from acute hospitals. Administration incidents were implicated in the majority of the reported medication incidents (59%), followed by prescribing (10.8%) and dispensing (9.9%), while the nondescript "other medication incidents" accounted for 20.3% of total incidents. The majority of reports were made by nursing and midwifery staff (80%), with medical and dental professionals reporting the lowest number of incidents (n=56, 2%). CONCLUSIONS: The majority of medication incidents in this study were reported by nursing and midwifery staff, and were due to administration incidents. There is a clear need to elucidate the reasons for the limited contribution of the medical and dental professionals to reporting medication incidents.

  18. Synchrotron-radiation experiments with recoil ions

    International Nuclear Information System (INIS)

    Levin, J.C.

    1989-01-01

    Studies of atoms, ions and molecules with synchrotron radiation have generally focused on measurements of properties of the electrons ejected during, or after, the photoionization process. Much can also be learned, however, about the atomic or molecular relaxation process by studies of the residual ions or molecular fragments following inner-shell photoionization. Measurements are reported of mean kinetic energies of highly charged argon, krypton, and xenon recoil ions produced by vacancy cascades following inner-shell photoionization using white and monochromatic synchrotron x radiation. Energies are much lower than for the same charge-state ions produced by charged-particle impact. The results may be applicable to design of future angle-resolved ion-atom collision experiments. Photoion charge distributions are presented and compared with other measurements and calculations. Related experiments with synchrotron-radiation produced recoil ion, including photoionization of stored ions and measurement of shakeoff in near-threshold excitation, are briefly discussed. 24 refs., 6 figs., 1 tab

  19. Free-Free Transitions in the Presence of Laser Fields at Very Low Incident Electron Energy

    Science.gov (United States)

    Bhatia, A. K.; Sinha, Chandana

    2010-01-01

    We study the free-free transition in electron-hydrogenic systems in ground state in presence of an external laser field at very loud incident energies. The laser field is treated classically while the collision dynamics is treated quantum mechanically. The laser field is chosen to be monochromatic, linearly polarized and homogeneous. The incident electron is considered to be dressed by the laser in a nonperturbative manner by choosing a Volkov wave function for it. The scattering weave function for the electron is solved numerically by taking into account the effect of the electron exchange, short-range as well as of the long-range interactions to get the S and P wave phase shifts while for the higher angular momentum phase shifts the exchange approximation has only been considered. We calculate the laser assisted differential cross sections (LADCS) for the aforesaid free-free transition process for single photon absorption/emission. The laser intensity is chosen to be much less than the atomic field intensity. A strong suppression is noted in the LADCS as compared to the field free (FF) cross sections. Unlike the FF ones, the LADCS exhibit some oscillations having a distinct maximum at a low value of the scattering angle depending on the laser parameters as well as on the incident energies.

  20. ERMS - Environmental Radiation Monitoring System

    International Nuclear Information System (INIS)

    Vax, Eran; Sarusi, Benny; Sheinfeld, Mati; Levinson, Shmuel; Brandys, Irad; Sattinger, Danny; Wengrowicz, Udi; Tshuva, Avi; Tirosh, Dan

    2008-01-01

    A new Environmental Radiation Monitoring System (ERMS) has been developed in the NRCN as an extensive tool to be applied in case of nuclear malfunction or Nuclear Disposal Device (NDD) incident, as well as for routine radiation monitoring of the reactor's vicinity. The system collects real-time environmental data such as: gamma radiation, wind speed, wind direction, and temperature for monitoring purposes. The ERMS consists of a main Control Center and an array of monitoring stations. Fixed, environmental, gamma radiation monitoring stations are installed at the reactor's surroundings while portable stations can be posted rapidly along the wind direction, enhancing the spatial sampling of the radiation measurements and providing better hazard assessment at an emergency event. The presented ERMS, based on industrial standards for hardware and network protocols, is a reliable standalone system which upgrades the readiness to face a nuclear emergency event by supplying real-time, integrated meteorological and radiation data. (author)

  1. Gravitational scattering of electromagnetic radiation

    Science.gov (United States)

    Brooker, J. T.; Janis, A. I.

    1980-01-01

    The scattering of electromagnetic radiation by linearized gravitational fields is studied to second order in a perturbation expansion. The incoming electromagnetic radiation can be of arbitrary multipole structure, and the gravitational fields are also taken to be advanced fields of arbitrary multipole structure. All electromagnetic multipole radiation is found to be scattered by gravitational monopole and time-varying dipole fields. No case has been found, however, in which any electromagnetic multipole radiation is scattered by gravitational fields of quadrupole or higher-order multipole structure. This lack of scattering is established for infinite classes of special cases, and is conjectured to hold in general. The results of the scattering analysis are applied to the case of electromagnetic radiation scattered by a moving mass. It is shown how the mass and velocity may be determined by a knowledge of the incident and scattered radiation.

  2. Radiation Practices. Annual report 2004

    International Nuclear Information System (INIS)

    Rantanen, E.

    2005-06-01

    particularly concerned assessments of the health risks of mobile communications and methods of determining radiation exposure caused by mobile phones. There were 18 abnormal incidents involving the use of radiation in 2004. Six of these incidents concerned the use of radiation in industry, research and education, eleven involved medical uses of radiation and one concerned the use of non-ionizing radiation. None of these incidents resulted in serious consequences. (orig.)

  3. Radiological incidents in industrial gamma radiography in the Philippines, 1979-1993

    International Nuclear Information System (INIS)

    Borras, A.M.

    1994-01-01

    Among the many practices of radiation sources, the practice of industrial gamma radiography in the country has the most number of reported radiological incidents. During the past fourteen (14) years, from 1979-1993, twenty (20) incidents that have occurred were reported to the Institute. This paper presents the nature and extent of the 20 reported incidents as well as the results of the analysis of why these incidents happened. The results of the analysis showed that the causes of these incidents are mainly human error and equipment failure. Hence, the factors that can minimize or prevent the chance of occurrence and/or recurrence of incidents and in minimizing the hazard in case of radiological incidents are: a) proper training and re-training of personnel; b) proper and regular inspection and maintenance of equipment; c) adequate radiation survey; and d) proper storage and inventory of the radiography sealed sources. (author). 3 refs.; 5 figs.; 1 tab

  4. Laser synchrotron radiation and beam cooling

    Energy Technology Data Exchange (ETDEWEB)

    Esarey, E.; Sprangle, P.; Ting, A. [Naval Research Lab., Washington, DC (United States)] [and others

    1995-12-31

    The interaction of intense {approx_gt} 10{sup 18} W/cm{sup 2}, short pulse ({approx_lt} 1 ps) lasers with electron beams and plasmas can lead to the generation of harmonic radiation by several mechanisms. Laser synchrotron radiation may provide a practical method for generating tunable, near monochromatic, well collimated, short pulse x-rays in compact, relatively inexpensive source. The mechanism for the generation of laser synchrotron radiation is nonlinear Thomson scattering. Short wavelengths can be generated via Thomson scattering by two methods, (i) backscattering from relativistic electron beams, in which the radiation frequency is upshifted by the relativistic factor 4{gamma}{sup 2}, and (ii) harmonic scattering, in which a multitude of harmonics are generated with harmonic numbers extending out to the critical harmonic number nc{approx_equal}a{sub 0}{sup 3} {much_gt} 1, where a{sub 0} {approx_equal}10{sup -9}{lambda}I{sup 1/2}, {lambda} is the laser wavelength in {mu}m and I is the laser intensity in W/cm{sup 2}. Laser synchrotron sources are capable of generating short ({approx_lt} ps) x-ray pulses with high peak flux ({approx_gt} 10{sup 21} photons/s) and brightness ({approx_gt}{sup 19} photons/s-mm{sup 2}-mrad{sup 2} 0.1%BW. As the electron beam radiates via Thomson scattering, it can subsequently be cooled, i.e., the beam emittance and energy spread can be reduced. This cooling can occur on rapid ({approximately} ps) time scales. In addition, electron distributions with sufficiently small axial energy spreads can be used to generate coherent XUV radiation via a laser-pumped FEL mechanism.

  5. Classical and ablative Richtmyer-Meshkov instability and other ICF-relevant plasma flows diagnosed with monochromatic x-ray imaging

    International Nuclear Information System (INIS)

    Aglitskiy, Y; Metzler, N; Karasik, M; Velikovich, A L; Zalesak, S T; Schmitt, A J; Serlin, V; Weaver, J; Obenschain, S P; Gardner, J H

    2008-01-01

    In inertial confinement fusion (ICF) and high-energy density physics (HEDP), the most important manifestations of the hydrodynamic instabilities and other mixing processes involve lateral motion of the accelerated plasmas. In order to understand the experimental observations and to advance the numerical simulation codes to the point of predictive capability, it is critically important to accurately diagnose the motion of the dense plasma mass. The most advanced diagnostic technique recently developed for this purpose is the monochromatic x-ray imaging that combines large field of view with high contrast, high spatial resolution and large throughput, ensuring high temporal resolution at large magnification. Its application made it possible for the experimentalists to observe for the first time important hydrodynamic effects that trigger compressible turbulent mixing in laser targets, such as ablative Richtmyer-Meshkov (RM) instability, feedout, interaction of an RM-unstable interface with shock and rarefaction waves. It also helped to substantially improve the accuracy of diagnosing many other important plasma flows, ranging from laser-produced jets to electromagnetically driven wires in a Z-pinch, and to test various methods suggested for mitigation of the Rayleigh-Taylor instability. We will review the results obtained with the aid of this technique in ICF-HEDP studies at the Naval Research Laboratory and the prospects of its future applications.

  6. Imaging of monochromatic beams by measuring secondary electron bremsstrahlung for carbon-ion therapy using a pinhole x-ray camera

    Science.gov (United States)

    Yamaguchi, Mitsutaka; Nagao, Yuto; Ando, Koki; Yamamoto, Seiichi; Sakai, Makoto; Parajuli, Raj Kumar; Arakawa, Kazuo; Kawachi, Naoki

    2018-02-01

    A feasibility study on the imaging of monochromatic carbon-ion beams for carbon-ion therapy was performed. The evaluation was based on Monte Carlo simulations and beam-irradiation experiments, using a pinhole x-ray camera, which measured secondary electron bremsstrahlung (SEB). The simulation results indicated that the trajectories of the carbon-ion beams with injection energies of 278, 249 and 218 MeV/u in a water phantom, were clearly imaged by measuring the SEB with energies from 30 to 60 keV, using a pinhole camera. The Bragg-peak positions for these three injection energies were located at the positions where the ratios of the counts of SEB acquisitions to the maximum counts were approximately 0.23, 0.26 and 0.29, respectively. Moreover, we experimentally demonstrated that it was possible to identify the Bragg-peak positons, at the positions where the ratios coincided with the simulation results. However, the estimated Bragg-peak positions for the injection energies of 278 and 249 MeV/u were slightly deeper than the expected positions. In conclusion, for both the simulations and experiments, we found that the 25 mm shifts in the Bragg-peak positions can be observed by this method.

  7. Incident users of antipsychotics

    DEFF Research Database (Denmark)

    Baandrup, Lone; Kruse, Marie

    2016-01-01

    PURPOSE: In Denmark, as well as in many other countries, consumption of antipsychotics is on the rise, partly due to increasing off-label use. The aim of this study was to analyze and quantify the extent of off-label use and polypharmacy in incident users of antipsychotic medication, and to examine...... initial antipsychotic prescribing patterns and associated use of mental health care services. METHOD: Population-based cohort study linking the following Danish national registers: the Central Psychiatric Research Register, the Register of Medicinal Product Statistics, and Statistics Denmark. RESULTS...

  8. Improving freight crash incident management.

    Science.gov (United States)

    2015-06-01

    The objective of this study was to determine the most effective way to mitigate the effect of freight : crash incidents on Louisiana freeways. Candidate incident management strategies were reviewed from : practice in other states and from those publi...

  9. Common Causes of Pesticide Incidents

    Science.gov (United States)

    There are many types of pesticide incidents. EPA staff analyze pesticide incident reports involving people (including children and farm workers), pets, domestic animals, wildlife including bees and other pollinators, and the environment.

  10. Radiation protection

    CERN Multimedia

    CERN. Geneva

    2001-01-01

    This will be a simple explanation of the reasons why CERN has to be careful about radiation protections issues, a practical guide on how to recognize radiation dangers, the monitoring systems that make sure radiation levels are well tolerable norms, and a quick summary of what radiation levels mean in terms of personal risk.

  11. Biological assessment of radiation damage of ATP by soft X-rays

    International Nuclear Informatio