WorldWideScience

Sample records for incident monochromatic radiation

  1. Light trapping for emission from a photovoltaic cell under normally incident monochromatic illumination

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Yasuhiko, E-mail: takeda@mosk.tytlabs.co.jp; Iizuka, Hideo; Mizuno, Shintaro; Hasegawa, Kazuo; Ichikawa, Tadashi; Ito, Hiroshi; Kajino, Tsutomu [Toyota Central Research and Development Laboratories, Inc., 41-1, Yokomichi, Nagakute, Aichi 480-1192 (Japan); Ichiki, Akihisa; Motohiro, Tomoyoshi [Green Mobility Collaborative Research Center, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601 (Japan)

    2014-09-28

    We have theoretically demonstrated a new light-trapping mechanism to reduce emission from a photovoltaic (PV) cell used for a monochromatic light source, which improves limiting conversion efficiency determined by the detailed balance. A multilayered bandpass filter formed on the surface of a PV cell has been found to prevent the light generated inside by radiative recombination from escaping the cell, resulting in a remarkable decrease of the effective solid angle for the emission. We have clarified a guide to design a suitable configuration of the bandpass filter and achieved significant reduction of the emission. The resultant gain in monochromatic conversion efficiency in the radiative limit due to the optimally designed 18-layerd bandpass filters is as high as 6% under normally incident 1064 nm illumination of 10 mW/cm²~ 1 kW/cm², compared with the efficiency for the perfect anti-reflection treatment to the surface of a conventional solar cell.

  2. Optimum angle of incidence for monochromatic interference in transparent films on absorbing substrates

    International Nuclear Information System (INIS)

    Muller, R.H.; Sand, M.L.

    1980-01-01

    Angles of incidence for s- and p-polarized light have been computed and confirmed experimentally for which monochromatic interference in transparent thin films on absorbing substrates results in optimum interference fringe contrast (visibility=1). Under these angles of incidence and with polarized light, film thickness determinations which are not possible at normal incidence or with unpolarized light can be carried out by use of thin-film interference

  3. Monochromatization of synchrotron radiation for studies in photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Murty, P.S.

    1981-01-01

    Synchrotron radiation provides a tunable photon source which bridges the wavelength gap between HeI and AlKsub(α) radiation sources in photoelectron spectroscopy. The essential component for using synchrotron radiation is a monochromator. Some design features of the monochromators fabricated at Stanford, U.S.A., and Orsay, France, are described. The Stanford monochromator is a silicon crystal monochromator yielding 8 keV X-ray beam and is used with SPEAR storage ring facility, while the Orsay monochromator is a grazing incidence grating monochromator used for UPS studies. (M.G.B.)

  4. Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jost, Gregor; Mensing, Tristan; Golfier, Sven; Lawaczeck, Ruediger; Pietsch, Hubertus; Huetter, Joachim; Cibik, Levent; Gerlach, Martin; Krumrey, Michael; Fratzscher, Daniel; Arkadiev, Vladimir; Wedell, Reiner; Haschke, Michael; Langhoff, Norbert; Wust, Peter; Luedemann, Lutz [TRG Diagnostic Imaging, Bayer Schering Pharma AG, 13353 Berlin (Germany); Department of Radiotherapy, Charite Medical Centre, 13353 Berlin (Germany); TRG Diagnostic Imaging, Bayer Schering Pharma AG, 13353 Berlin (Germany); Physikalisch-Technische Bundesanstalt, 10587 Berlin (Germany); Institute of Applied Photonics e.V., 12489 Berlin (Germany); Institute for Scientific Instruments GmbH, 12489 Berlin (Germany); Department of Radiotherapy, Charite Medical Centre, 13353 Berlin (Germany)

    2009-06-15

    Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detection system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasi-monochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten K{alpha} emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement

  5. Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography

    International Nuclear Information System (INIS)

    Jost, Gregor; Mensing, Tristan; Golfier, Sven; Lawaczeck, Ruediger; Pietsch, Hubertus; Huetter, Joachim; Cibik, Levent; Gerlach, Martin; Krumrey, Michael; Fratzscher, Daniel; Arkadiev, Vladimir; Wedell, Reiner; Haschke, Michael; Langhoff, Norbert; Wust, Peter; Luedemann, Lutz

    2009-01-01

    Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detection system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasi-monochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten Kα emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement factor

  6. Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography.

    Science.gov (United States)

    Jost, Gregor; Mensing, Tristan; Golfier, Sven; Lawaczeck, Rüdiger; Pietsch, Hubertus; Hütter, Joachim; Cibik, Levent; Gerlach, Martin; Krumrey, Michael; Fratzscher, Daniel; Arkadiev, Vladimir; Wedell, Reiner; Haschke, Michael; Langhoff, Norbert; Wust, Peter; Lüdemann, Lutz

    2009-06-01

    Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detection system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasimonochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten Kalpha emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement

  7. A Superpowerful Source of Far-Ultraviolet Monochromatic Radiation

    International Nuclear Information System (INIS)

    Ivanova, E.P.; Ivanov, A.L.

    2005-01-01

    In several independent experiments investigating the interaction between the optical field of an intense laser pulse and a xenon cluster beam, we recorded an anomalously high quantum yield of the plasma radiation in the region 10-15 nm. In several cases, the conversion efficiency into the hemisphere reached 10% of the pumping pulse energy. The nature of this phenomenon has not yet been adequately explained. A high conversion efficiency is shown to be possible when producing a plasma with optimal parameters for the amplification of spontaneous radiation on Ni-like xenon transitions to be generated. In a collisional-radiative model, we performed detailed atomic-kinetic calculations of the gains and radiation spectra on the transitions with λ ≅ 4, 10, and 11.3 nm and in the region 13-13.9 nm. For each transition, we determined the time dependences of the gains on plasma parameters. The theoretical and experimental values of the optimal plasma parameters and energy yields of the radiation are in close agreement. Using a theoretical model, we propose possible plasma pumping schemes to achieve the maximum yield of the intense, narrowly beamed soft X-ray radiation. At a pumping pulse repetition rate of 10 4 Hz, the output power for various Ni-like xenon transitions ranges from 100 to 5 x 10 3 W

  8. Three-dimensional monochromatic x-ray computed tomography using synchrotron radiation

    Science.gov (United States)

    Saito, Tsuneo; Kudo, Hiroyuki; Takeda, Tohoru; Itai, Yuji; Tokumori, Kenji; Toyofuku, Fukai; Hyodo, Kazuyuki; Ando, Masami; Nishimura, Katsuyuki; Uyama, Chikao

    1998-08-01

    We describe a technique of 3D computed tomography (3D CT) using monochromatic x rays generated by synchrotron radiation, which performs a direct reconstruction of a 3D volume image of an object from its cone-beam projections. For the development, we propose a practical scanning orbit of the x-ray source to obtain complete 3D information on an object, and its corresponding 3D image reconstruction algorithm. The validity and usefulness of the proposed scanning orbit and reconstruction algorithm were confirmed by computer simulation studies. Based on these investigations, we have developed a prototype 3D monochromatic x-ray CT using synchrotron radiation, which provides exact 3D reconstruction and material-selective imaging by using the K-edge energy subtraction technique.

  9. Total reflection X-ray fluorescence analysis with synchrotron radiation monochromatized by multilayer structures

    International Nuclear Information System (INIS)

    Rieder, R.; Wobrauschek, P.; Ladisich, W.; Streli, C.; Aiginger, H.; Garbe, S.; Gaul, G.; Knoechel, A.; Lechtenberg, F.

    1995-01-01

    To achieve lowest detection limits in total reflection X-ray fluorescence analysis (TXRF) synchrotron radiation has been monochromatized by a multilayer structure to obtain a relative broad energy band compared to Bragg single crystals for an efficient excitation. The energy has been set to 14 keV, 17.5 keV, 31 keV and about 55 keV. Detection limits of 20 fg and 150 fg have been achieved for Sr and Cd, respectively. ((orig.))

  10. Radiation incidents in dentistry

    International Nuclear Information System (INIS)

    Lovelock, D.J.

    1996-01-01

    Most dental practitioners act as their own radiographer and radiologist, unlike their medical colleagues. Virtually all dental surgeons have a dental X-ray machine for intraoral radiography available to them and 40% of dental practices have equipment for dental panoramic tomography. Because of the low energy of X-ray equipment used in dentistry, radiation incidents tend to be less serious than those associated with other aspects of patient care. Details of 47 known incidents are given. The advent of the 1985 and 1988 Ionising Radiation Regulations has made dental surgeons more aware of the hazards of radiation. These regulations, and general health and safety legislation, have led to a few dental surgeons facing legal action. Because of the publicity associated with these court cases, it is expected that there will be a decrease in radiation incidents arising from the practice of dentistry. (author)

  11. A zone plate soft x-ray microscope using monochromatized undulator radiation at the beamline NE1B of the TRISTAN Accumulation Ring

    International Nuclear Information System (INIS)

    Wang, J.; Kagoshima, Y.; Miyahara, T.; Ando, M.; Aoki, S.; Anderson, E.; Attwood, D.; Kern, D.

    1995-01-01

    A soft x-ray microscope has been developed at the beamline NE1B of the 6.5-GeV TRISTAN Accumulation Ring (AR). It makes use of undulator radiation as its source and a zone plate with the outermost zone width of 50 nm as its imaging element. It has two main features. First, the undulator radiation is monochromatized by a grazing incidence grating monochromator to match to the monochromaticity requirement of the zone plate. Second, a visible light prefocus unit consisting of two objectives has been designed and installed in the x-ray microscope. The x-ray optical system of the microscope can be adjusted easily, quickly, and precisely by using this unit. The microscope can resolve 55-nm lines and spaces in a zone plate test pattern

  12. Nitrogen capillary plasma as a source of intense monochromatic radiation at 2.88 nm

    Energy Technology Data Exchange (ETDEWEB)

    Vrba, P., E-mail: vrbovmir@fbmi.cvut.cz [Institute of Plasma Physics, Academy of Sciences, Za Slovankou 3, Prague 8 (Czech Republic); Vrbova, M. [Faculty of Biomedical Engineering, CTU in Prague, Sitna 3105, Kladno 2 (Czech Republic); Zakharov, S.V. [EPPRA sas, Villebon/Yvette (France); Zakharov, V.S. [EPPRA sas, Villebon/Yvette (France); KIAM RAS, Moscow (Russian Federation); Jancarek, A.; Nevrkla, M. [Faculty of Nuclear Science and Physical Engineering, CTU in Prague, Brehova 7, Prague 1 (Czech Republic)

    2014-10-15

    Highlights: • Pinching capillary discharge is studied as a source of monochromatic SXR. • Modeling of the laboratory device was performed by RMHD Z* code. • Results of computer and laboratory experiments are presented. - Abstract: Capillary discharge plasma related to our laboratory device is modeled and the results are compared with experimental data. Time dependences of selected plasma quantities (e.g. plasma mass density, electron temperature and density and emission intensities) evaluated by 2D Radiation-Magneto-Hydro-Dynamic code Z* describe plasma evolution. The highest output pulse energy at 2.88 nm wavelength is achieved for nitrogen filling pressure ∼100 Pa. The estimated output energy of monochromatic radiation 5.5 mJ sr{sup −1} (∼10{sup 14} photons sr{sup −1}) corresponds properly to observe experimental value ∼3 × 10{sup 13} photons sr{sup −1}. Ray tracing inspection along the capillary axis proves an influence of radiation self-absorption for the investigated wavelength. The spectra, evaluated using the FLY code, agree to the measured ones.

  13. Thickness determination of thin solid films by angle-resolved X-ray fluorescence spectrometry using monochromatized synchrotron radiation

    Science.gov (United States)

    Schmitt, W.; Drotbohm, P.; Rothe, J.; Hormes, J.; Ottermann, C. R.; Bange, K.

    1995-05-01

    Thickness measurements by the method of angle-resolved, self-ratio X-ray fluorescence spectrometry (AR/SR/XFS) have been carried out on thin solid films using monochromatized synchrotron radiation at the Bonn storage ring ELSA. Synchrotron radiation was monochromatized by means of a double-crystal monochromator and fluorescence radiation was detected by a Si(Li) semiconductor detector. The results for sample systems consisting of Au on Si, Cr on SiO2 and TiO2 on alkali-free glass are very satisfactory and agree well with results obtained by other methods.

  14. Combined tunable diode laser absorption spectroscopy and monochromatic radiation thermometry in ammonium dinitramide-based thruster

    Science.gov (United States)

    Zeng, Hui; Ou, Dongbin; Chen, Lianzhong; Li, Fei; Yu, Xilong

    2018-02-01

    Nonintrusive temperature measurements for a real ammonium dinitramide (ADN)-based thruster by using tunable diode laser absorption spectroscopy and monochromatic radiation thermometry are proposed. The ADN-based thruster represents a promising future space propulsion employing green, nontoxic propellant. Temperature measurements in the chamber enable quantitative thermal analysis for the thruster, providing access to evaluate thermal properties of the thruster and optimize thruster design. A laser-based sensor measures temperature of combustion gas in the chamber, while a monochromatic thermometry system based on thermal radiation is utilized to monitor inner wall temperature in the chamber. Additional temperature measurements of the outer wall temperature are conducted on the injector, catalyst bed, and combustion chamber of the thruster by using thermocouple, respectively. An experimental ADN thruster is redesigned with optimizing catalyst bed length of 14 mm and steady-state firing tests are conducted under various feed pressures over the range from 5 to 12 bar at a typical ignition temperature of 200°C. A threshold of feed pressure higher than 8 bar is required for the thruster's normal operation and upstream movement of the heat release zone is revealed in the combustion chamber out of temperature evolution in the chamber.

  15. Incidents with hazardous radiation sources

    International Nuclear Information System (INIS)

    Schoenhacker, Stefan

    2016-01-01

    Incidents with hazardous radiation sources can occur in any country, even those without nuclear facilities. Preparedness for such incidents is supposed to fulfill globally agreed minimum standards. Incidents are categorized in incidents with licensed handling of radiation sources as for material testing, transport accidents of hazardous radiation sources, incidents with radionuclide batteries, incidents with satellites containing radioactive inventory, incidents wit not licensed handling of illegally acquired hazardous radiation sources. The emergency planning in Austria includes a differentiation according to the consequences: incidents with release of radioactive materials resulting in restricted contamination, incidents with release of radioactive materials resulting in local contamination, and incidents with the hazard of e@nhanced exposure due to the radiation source.

  16. The effect of exposure to enhanced UV-B radiation on the penetration of monochromatic and polychromatic UV-B radiation in leaves of Brassica napus

    International Nuclear Information System (INIS)

    Cen, Y.-P.; Bornman, J.F.

    1993-01-01

    Using quartz optical fibres, penetration of both monochromatic (310 nm) and polychromatic UV-B (280–320 nm) radiation in leaves of Brassica napus L. (cv. Ceres) was measured. Plants were grown under either visible light (750 μmol m −2 s −1 photosynthetically active radiation) or with the addition of 8. 9 KJ m −2 day −1 biologically effective UV-B (UV-B BE ) radiation. Results showed that of the 310 nm radiation that penetreated the leaf, 90% was within the intial one third of the leaf with high attenuation in the leaf epidermis, especially in UV-treated plants. Polychromatic UV-B radiation, relative to incident radiation, showed a relatively uniform spectral distribution within the leaf, except for collimated radiation. Over 30% of the UV-screening pigments in the leaf, including flavonoids, were found in the adaxial epidermal layer, making this layer less transparent to UV-B radiation than the abaxial epidermis, which contained less than 12% of the UV-screening pigments. UV-screening pigments increased by 20% in UV-treated leaves relative to control leaves. Densely arranged epicuticular wax on the adaxial leaf surface of UV-treated plants may have further decreased penetration of UV-B radiation by reflectance. An increased leaf thickness, and decreases in leaf area and leaf dry weight were also found for UV-treated plants. (author)

  17. Monochromaticity of optical radiation of Smith-Purcell generated by electron beam with 75 keV energy

    International Nuclear Information System (INIS)

    Adishchev, Yu.N.; Vukolov, A.V.; Karlovets, D.V.; Potylitsyn, A.P.; Kube, G.

    2005-01-01

    The monochromatism of the Smith-Purcell optical radiation generated by a 75-keV electron beam with a final emittance of ε = 0.65 x 10 -4 mm rad that passes over an optical grating with a period of D = 0.833 μm has been analyzed. It has been shown that the monochromatism (line width) of the Smith-Purcell radiation is determined not only by the angular aperture of a monochromator but also by the divergence of the electron beam [ru

  18. Studies on auger enhancement of biological systems with the use of monochromatic synchrotron radiation

    International Nuclear Information System (INIS)

    Shinohara, K.

    1985-01-01

    HeLa cells were incubated either with BrdUrd (5 x 10 -5 M) and deoxycytidine (10 -5 M) for 18 hr (corresponding to one generation time) or with gallium citrate (10 -5 M) for 24 hr. The cells on the membrane filter were irradiated with monochromatic synchrotron radiation at 0.90 A, 1.00 A, or 1.14 A and cell survival was determined by colony-forming ability. The results show that the sensitivity of BrdUrd-labeled cells was higher when they were irradiated at 0.90 a than at 100 A, but cells without BrdUrd showed no difference in sensitivity when irradiated at these two wavelengths. The growth curve of HeLa cells in the presence of gallium citrate (10 -4 M). Shows that during the test period of 20-60 hr of colony-forming ability was not affected although the growth rate decreased slightly. Data show no increase in the sensitivity of gallium-labeled HeLa cells over that of controls to irradiation with monochromatic synchrotron radiation at 1.14 A, slightly shorter than the K absorption edge for the gallium (1.196 A). Since gallium has been shown to concentrate in lysosome, the present results, suggest that the range of Auger enhancement is not great enough for interaction with DNA in nucleus from lysosome in cytoplasm, although the possibility should be considered that the accumulated number of gallium atoms (∼ 5 x 10 7 /cell) may not be enough to produce detectable enhancement effects

  19. Thermoluminescence dependence on the wavelength of monochromatic UV-radiation in Cu-doped KCl and KBr at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Perez R, A.; Piters, T.; Aceves, R.; Rodriguez M, R.; Perez S, R., E-mail: rperez@cifus.uson.mx [Universidad de Sonora, Departamento de Investigaciones en Fisica, Apdo. Postal 5-088, 83190 Hermosillo, Sonora (Mexico)

    2014-08-15

    Thermoluminescence (Tl) dependence on the UV irradiation wavelengths from 200 to 500 nm in Cu-doped KCl and KBr crystals with different thermal treatment has been analyzed. Spectrum of the Tl intensity of each material show lower intensity at wavelengths longer than 420 nm. The Tl intensity depends on the irradiation wavelength. Structure of the Tl intensity spectrum of each sample is very similar to the structure of its optical absorption spectrum, indicating that at each wavelength, monochromatic radiation is absorbed to produce electronic transitions and electron hole pairs. Thermoluminescence of materials with thermal treatment at high temperature shows electron-hole trapping with less efficiency. The results show that Cu-doped alkali-halide materials are good detectors of a wide range of UV monochromatic radiations and could be used to measure UV radiation doses. (Author)

  20. Thermoluminescence dependence on the wavelength of monochromatic UV-radiation in Cu-doped KCl and KBr at room temperature

    International Nuclear Information System (INIS)

    Perez R, A.; Piters, T.; Aceves, R.; Rodriguez M, R.; Perez S, R.

    2014-08-01

    Thermoluminescence (Tl) dependence on the UV irradiation wavelengths from 200 to 500 nm in Cu-doped KCl and KBr crystals with different thermal treatment has been analyzed. Spectrum of the Tl intensity of each material show lower intensity at wavelengths longer than 420 nm. The Tl intensity depends on the irradiation wavelength. Structure of the Tl intensity spectrum of each sample is very similar to the structure of its optical absorption spectrum, indicating that at each wavelength, monochromatic radiation is absorbed to produce electronic transitions and electron hole pairs. Thermoluminescence of materials with thermal treatment at high temperature shows electron-hole trapping with less efficiency. The results show that Cu-doped alkali-halide materials are good detectors of a wide range of UV monochromatic radiations and could be used to measure UV radiation doses. (Author)

  1. Dichromatic and monochromatic laser radiation effects on antibiotic resistance, biofilm formation, and division rate of Pantoea agglomerans

    Science.gov (United States)

    Thomé, A. M. C.; Souza, B. P.; Mendes, J. P. M.; Cardoso, A. F. R.; Soares, L. C.; Trajano, E. T. L.; Fonseca, A. S.

    2018-06-01

    Since infection is a common cause of delayed wound healing, it is important to understand the effect of low-level laser therapy (LLLT) in bacterial mechanisms. In this study we evaluated the effects of LLLT on antibiotic resistance, division rate, and biofilm formation of Pantoea agglomerans. P. agglomerans samples were isolated from human pressure injuries in humans and cultures were exposed to low-level monochromatic and simultaneous dichromatic laser radiation to study the susceptibility of an antimicrobial to ampicillin and piperacillin  +  tazobactam, quantification of areas of bacterial colonies, and biofilm formation of bacterial cells. Fluence, wavelength, and emission mode were used in the therapeutic protocols for wound healing. The data showed no changes in the areas of the colonies, but dichromatic laser radiation decreased biofilm formation, while a monochromatic red laser at low dose increased biofilm formation and infrared at high dose decreased antibiotic resistance to ampicillin. LLLT modulates antibiotic resistance and biofilm formation of P. agglomerans, but these depend on the laser irradiation parameters, since dichromatic laser radiation induces biological effects that differ from those induced by monochromatic laser radiation. Thus, simultaneous dichromatic low-level red and infrared lasers could be a new option for the treatment of infected wounds, reducing biofilm formation, without altering antibiotic resistance and the division rate of P. agglomerans cultures.

  2. Construction of x-ray Kβ filters to monochromatize the radiation of a conventional x-ray tube

    International Nuclear Information System (INIS)

    Moreira, M.V.B.; Oliveira, A.G.

    1987-01-01

    The construction of Zr and Nb Kβ filters to produce monochromatic radiation of a conventional X-ray Mo-tube (λK a = 0.7107 A) is described. Disks of NB and Zr, 6.4 mm in diameter and 0.03 to 0.06 mm thick, were prepared. The filters performance was tested by means of NaCl powder difraction patterns. (author) [pt

  3. Comparison of UV action spectra for lethality and mutation in Salmonella typhimurium using a broad band source and monochromatic radiations

    International Nuclear Information System (INIS)

    Calkins, John; Selby, Christopher; Enoch, H.G.

    1987-01-01

    The UV-B region (280-320 nm) is thought to be primarily responsible for the mutagenic, lethal, and carcinogenic effects of solar radiation. We have conducted UV-B action spectroscopy for mutagenesis and survival of Ames' Salmonella typhimurium strain TA98 (uvrB, pKM101) using both monochromatic radiation from a dye laser and broader bandwidth radiation emitted from FS-20 sunlamps. A series of optical filters having different transmission cut-offs together with the sunlamp source provided bandwidths having successively less short wavelength components from which a ''broad band'' action spectrum was deduced. The two sets of action spectra differed both qualitatively and quantitatively: in comparison to the monochromatic action spectra, the ''broad band'' spectra showed up to a 200-fold reduced efficiency for both mutation induction and lethality by UV-B wavelengths. These results suggest a large protective effect of the background UV-A and/or visible radiations which were present during the broad spectrum irradiations and which are also present in solar radiation. Additional experiments show that to the extent tested this protective effect is not due to photo-reactivation or irradiance (dose rate) effects. (author)

  4. Nonlinear real index of refraction variations of a gas medium due to a monochromatic radiation near resonance

    International Nuclear Information System (INIS)

    Vasconcellos, J.I.C.

    1982-01-01

    The nonlinear real index of refraction variations of a gas medium due to a strong monochromatic radiation causing saturation effects is calculated. The gas is supposed to be composed of two-level molecules with which the external field is nearly resonant. It is assumed homogeneous (hard collisions, spontaneous decay) and inhomogeneous (Doppler effect) broadening mechanisms acting on the real index of refraction of the medium. The nonlinear dispersion of the medium is studied as a function of the detuning frequencies, saturation conditions and for various ratios between the homogeneous and inhomogeneous linewidths. In particular, the modification of the index of refraction due to saturation effects are emphasized. (Author) [pt

  5. Photon activation therapy of RG2 glioma carrying Fischer rats using stable thallium and monochromatic synchrotron radiation.

    Science.gov (United States)

    Ceberg, Crister; Jönsson, Bo-Anders; Prezado, Yolanda; Pommer, Tobias; Nittby, Henrietta; Englund, Elisabet; Grafström, Gustav; Edvardsson, Anneli; Stenvall, Anna; Strömblad, Susanne; Wingårdh, Karin; Persson, Bertil; Elleaume, Hélène; Baldetorp, Bo; Salford, Leif G; Strand, Sven-Erik

    2012-12-21

    75 RG2 glioma-carrying Fischer rats were treated by photon activation therapy (PAT) with monochromatic synchrotron radiation and stable thallium. Three groups were treated with thallium in combination with radiation at different energy; immediately below and above the thallium K-edge, and at 50 keV. Three control groups were given irradiation only, thallium only, or no treatment at all. For animals receiving thallium in combination with radiation to 15 Gy at 50 keV, the median survival time was 30 days, which was 67% longer than for the untreated controls (p = 0.0020) and 36% longer than for the group treated with radiation alone (not significant). Treatment with thallium and radiation at the higher energy levels were not effective at the given absorbed dose and thallium concentration. In the groups treated at 50 keV and above the K-edge, several animals exhibited extensive and sometimes contra-lateral edema, neuronal death and frank tissue necrosis. No such marked changes were seen in the other groups. The results were discussed with reference to Monte Carlo calculated electron energy spectra and dose enhancement factors.

  6. RADIATION CONTAMINATION INCIDENT AT ISOLDE

    CERN Multimedia

    2000-01-01

    On 27 June 2000 three specialists were investigating a problem with the extraction electrode of the high-resolution separator (HRS) in Isolde. Whilst using an endoscope in order to have a closer look at the interior, they came into contact with radioactive dust and became contaminated. The level of contamination was low and the radiation dose received by the 3 persons was far below the effective dose limit given in the CERN Radiation Safety Manual and in the regulations of the Host States.According to the usual procedure, the Director General has set up a Fact-Finding Group and an Accident Board in order to advise him on the steps and decisions tobe taken following this incident and in particular to avoid a recurrence.

  7. Computed tomography for light materials using a monochromatic X-ray beam produced by parametric X-ray radiation

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, Y., E-mail: yahayak@lebra.nihon-u.ac.jp [Laboratory for Electron Beam Research and Application, Nihon University, Narashinodai 7-24-1, Funabashi 274-8501 (Japan); Hayakawa, K.; Inagaki, M. [Laboratory for Electron Beam Research and Application, Nihon University, Narashinodai 7-24-1, Funabashi 274-8501 (Japan); Kaneda, T. [Nihon University School of Dentistry at Matsudo, Sakaecho-Nishi 2-870-1, Matsudo 271-8587 (Japan); Nakao, K.; Nogami, K. [Laboratory for Electron Beam Research and Application, Nihon University, Narashinodai 7-24-1, Funabashi 274-8501 (Japan); Sakae, T. [Nihon University School of Dentistry at Matsudo, Sakaecho-Nishi 2-870-1, Matsudo 271-8587 (Japan); Sakai, T.; Sato, I. [Laboratory for Electron Beam Research and Application, Nihon University, Narashinodai 7-24-1, Funabashi 274-8501 (Japan); Takahashi, Y. [Institute of Materials Structure Science, High Energy Accelerator Research Organization (KEK), Oho, Tsukuba 305-8501 (Japan); Tanaka, T. [Laboratory for Electron Beam Research and Application, Nihon University, Narashinodai 7-24-1, Funabashi 274-8501 (Japan)

    2013-08-15

    Computed tomography (CT) for light materials such as soft biological tissues was performed using a monochromatic X-ray beam provided by a parametric X-ray radiation (PXR) source at the Laboratory for Electron Beam Research and Application (LEBRA) of Nihon University. Using a high-efficiency flat panel detector (FPD), each projection image for CT was taken with exposure times of 5 or 10 s, and 60–360 projection images in each run were obtained with total measurement time of 5 min to 1 h. CT images were obtained from the projection images using the conventional calculation method. The typical tomograms obtained had sharp outlines, which are likely attributable to the propagation-based phase contrast.

  8. Photosensitized inactivation of DNA by monochromatic 334-nm radiation in the presence of 2-thiouracil: genetic activity and backbone breaks

    International Nuclear Information System (INIS)

    Peak, M.J.; Ito, A.; Peak, J.G.; Foote, C.S.

    1988-01-01

    Monochromatic 334-nm radiation delivered under aerobic conditions inactivates the genetic activity (ability to transform auxotrophic recipient cells to nutritional prototrophy) of isolated transforming Bacillus subtilis DNA. The presence of superoxide dismutase (SOD), catalase, and mannitol reduces the 334-nm inactivation. The rate of inactivation of the genetic activity by 334-nm radiation is enhanced fivefold by the sensitizer 2-thiouracil (s 2 Ura). This enhancement is substantially reversed when the irradiations are performed in the presence of mannitol, and, to a lesser extent, SOD. Catalase slightly reduces the s 2 Ura enhancement of 334-nm inactivation of transforming activity. Backbone breaks induced in the same DNA by aerobic 334-nm radiation were also enhanced markedly by the presence of s 2 Ura; this enhancement was reversed by the presence of mannitol and, to a lesser extent, SOD during irradiation. Catalase had no effect upon s 2 Ura-enhanced, 334-nm-induced SSBs. Whereas DNA breakage may be responsible for a portion of the inactivation of the DNA by the photosensitized reaction between s 2 Ura and 334-nm radiation, it is not the only inactivating lesion, because the yield of SSBs per lethal hit per unit length of DNA is not constant for all the irradiation conditions studied. (author)

  9. Quantum effects induced by a gap in the spectrum of atom-bath coupling constants: ''Freezing'' of atomic decay and monochromatic collective radiation

    International Nuclear Information System (INIS)

    Mogilevtsev, D.S.; Kilin, S.Ya.

    1994-08-01

    A specific kind of inhibition of atomic decay (''freezing of decay) and intense monochromatic collective radiation are predicted for a single two-level atom and for a system of atoms interacting with the field bath having the gap in the spectrum of coupling constants. (author). 10 refs, 5 figs

  10. Imaging of exploding wire plasmas by high-luminosity monochromatic X-ray backlighting using an X-pinch radiation source

    Energy Technology Data Exchange (ETDEWEB)

    Pikuz, S A; Shelkovenko, T A; Romanova, V M [Russian Academy of Sciences, Moscow (Russian Federation). P.N. Lebedev Physical Inst.; Hammer, D A [Cornell Univ., Ithaca, NY (United States). Laboratory of Plasma Studies; Faenov, A Ya; Pikuz, T A [VNIIFTRI, Mendeleevo (Russian Federation). Multicharged Ions Spectral Data Center

    1997-12-31

    A new diagnostic method for dense plasmas, monochromatic x-ray backlighting, is described. In this method, shadow images of a bright, dense plasma can be obtained with high spatial resolution using monochromatic radiation from a separate plasma, permitting a major reduction in the required backlighting source power. The object plasma is imaged utilizing spherically bent mica crystals as the x-ray optical elements. Images of test objects obtained using x-ray radiation having different photon energies are presented. Shadow images of exploding Al wire plasmas in the ls{sup 2}-1s3p line radiation of He-like Al XII are also shown. Spatial resolution as fine as 4 {mu}m is demonstrated. The scheme described is useful for backlighting extended high density plasmas, and could be a less costly alternative to using X-ray lasers for such purposes. (author). 7 figs., 10 refs.

  11. Nitrogen capillary plasma as a source of intense monochromatic radiation at 2.88 nm

    Czech Academy of Sciences Publication Activity Database

    Vrba, Pavel; Vrbová, M.; Zakharov, S.V.; Zakharov, V.S.; Jančárek, A.; Nevrkla, M.

    2014-01-01

    Roč. 196, October (2014), s. 24-30 ISSN 0368-2048 R&D Projects: GA ČR GAP102/12/2043; GA MŠk(CZ) LG13029 Grant - others:GA MŠk(CZ) CZ.1.07/2.3.00/20.0092 Institutional support: RVO:61389021 Keywords : Capillary Z-pinch * Water window radiation source * RHMD Code Z* Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.436, year: 2014 http://dx.doi.org/10.1016/j.elspec.2013.12.015

  12. Interactions of monochromatic visible light and near-IR radiation with cells: currently discussed mechanisms

    Science.gov (United States)

    Karu, Tiina I.

    1995-05-01

    Biological responses of cells to visible and near IR (laser) radiation occur due to physical and/or chemical changes in photoacceptor molecules, components of respiratory chains (cyt a/a3 in mitochondria, and cyt d in E. coli). As a result of the photoexcitation of electronic states, the following physical and/or chemical changes can occur: alteration of redox properties and acceleration of electron transfer, changes in biochemical activity due to local transient heating of chromophores, one-electron auto-oxidation and O2- production, and photodynamic action and 1O2 production. Different reaction channels can be activated to achieve the photobiological macroeffect. The primary physical and/or chemical changes induced by light in photoacceptor molecules are followed by a cascade of biochemical reactions in the cell that do not need further light activation and occur in the dark (photosignal transduction and amplification chains). These reactions are connected with changes in cellular homeostasis parameters. The crucial step here is thought to be an alteration of the cellular redox state: a shift towards oxidation is associated with stimulation of cellular vitality, and a shift towards reduction is linked to inhibition. Cells with a lower than normal pH, where the redox state is shifted in the reduced direction, are considered to be more sensitive to the stimulative action of light than those with the respective parameters being optimal or near optimal. This circumstance explains the possible variations in observed magnitudes of low-power laser effects. Light action on the redox state of a cell via the respiratory chain also explains the diversity of low-power laser effects. Beside explaining many controversies in the field of low-power laser effects (i.e., the diversity of effects, the variable magnitude or absence of effects in certain studies), the proposed redox-regulation mechanism may be a fundamental explanation of some clinical effects of irradiation, for

  13. Semiclassical interaction between monochromatic electromagnetic radiation and an atom with two unstable levels; some fallacious works by Kamenov-Bonchev

    International Nuclear Information System (INIS)

    Romashev, Yu. A.; Skorobogatov, G.A.

    1999-01-01

    The solution of the time-dependent Hamiltonian for the classical dipole interaction of a two-level atom with a monochromatic electromagnetic wave is presented. Both atomic energy levels are assumed to be unstable. The amplitudes and probabilities of transitions between the energy levels as well as the cross-sections of resonance absorption and induced emission are obtained explicitly. It is shown that in both stationary and nonstationary limits the instability of the lower level does not lead to a differential cross section of induced emission larger than those obtained from the Breit-Wigner formula in the standard collision theory. (authors)

  14. Orbital effects of a monochromatic plane gravitational wave with ultra-low frequency incident on a gravitationally bound two-body system

    Directory of Open Access Journals (Sweden)

    Lorenzo Iorio

    2014-09-01

    Full Text Available We analytically compute the long-term orbital variations of a test particle orbiting a central body acted upon by an incident monochromatic plane gravitational wave. We assume that the characteristic size of the perturbed two-body system is much smaller than the wavelength of the wave. Moreover, we also suppose that the wave's frequency νg is much smaller than the particle's orbital one nb. We make neither a priori assumptions about the direction of the wavevector kˆ nor on the orbital configuration of the particle. While the semi-major axis a is left unaffected, the eccentricity e, the inclination I, the longitude of the ascending node Ω, the longitude of pericenter ϖ and the mean anomaly ℳ undergo non-vanishing long-term changes of the form dΨ/dt=F(Kij;e,I,Ω,ω,Ψ=e,I,Ω,ϖ,M, where Kij, i,j=1,2,3 are the coefficients of the tidal matrix K. Thus, in addition to the variations of its orientation in space, the shape of the orbit would be altered as well. Strictly speaking, such effects are not secular trends because of the slow modulation introduced by K and by the orbital elements themselves: they exhibit peculiar long-term temporal patterns which would be potentially of help for their detection in multidecadal analyses of extended data records of planetary observations of various kinds. In particular, they could be useful in performing independent tests of the inflation-driven ultra-low gravitational waves whose imprint may have been indirectly detected in the Cosmic Microwave Background by the Earth-based experiment BICEP2. Our calculation holds, in general, for any gravitationally bound two-body system whose orbital frequency nb is much larger than the frequency νg of the external wave, like, e.g., extrasolar planets and the stars orbiting the Galactic black hole. It is also valid for a generic perturbation of tidal type with constant coefficients over timescales of the order of the orbital period of the perturbed particle.

  15. Natural background radiation and oncologic disease incidence

    International Nuclear Information System (INIS)

    Burenin, P.I.

    1982-01-01

    Cause and effect relationships between oncologic disease incidence in human population and environmental factors are examined using investigation materials of Soviet and foreign authors. The data concerning US white population are adduced. The role and contribution of natural background radiation oncologic disease prevalence have been determined with the help of system information analysis. The probable damage of oncologic disease is shown to decrease as the background radiation level diminishes. The linear nature of dose-response relationspip has been established. The necessity to include the life history of the studied population along with environmental factors in epidemiological study under conditions of multiplicity of cancerogenesis causes is emphasized

  16. Incidents with hazardous radiation sources; Zwischenfaelle mit gefaehrlichen Strahlenquellen

    Energy Technology Data Exchange (ETDEWEB)

    Schoenhacker, Stefan [Bundesministerium fuer Inneres, Traiskirchen (Austria). Abt. 1/9 - Zivilschutzschule

    2016-07-01

    Incidents with hazardous radiation sources can occur in any country, even those without nuclear facilities. Preparedness for such incidents is supposed to fulfill globally agreed minimum standards. Incidents are categorized in incidents with licensed handling of radiation sources as for material testing, transport accidents of hazardous radiation sources, incidents with radionuclide batteries, incidents with satellites containing radioactive inventory, incidents wit not licensed handling of illegally acquired hazardous radiation sources. The emergency planning in Austria includes a differentiation according to the consequences: incidents with release of radioactive materials resulting in restricted contamination, incidents with release of radioactive materials resulting in local contamination, and incidents with the hazard of e@nhanced exposure due to the radiation source.

  17. Analysis of monochromatic and quasi-monochromatic X-ray sources in imaging and therapy

    Science.gov (United States)

    Westphal, Maximillian; Lim, Sara; Nahar, Sultana; Orban, Christopher; Pradhan, Anil

    2017-04-01

    We studied biomedical imaging and therapeutic applications of recently developed quasi-monochromatic and monochromatic X-ray sources. Using the Monte Carlo code GEANT4, we found that the quasi-monochromatic 65 keV Gaussian X-ray spectrum created by inverse Compton scattering with relatavistic electron beams were capable of producing better image contrast with less radiation compared to conventional 120 kV broadband CT scans. We also explored possible experimental detection of theoretically predicted K α resonance fluorescence in high-Z elements using the European Synchrotron Research Facility with a tungsten (Z = 74) target. In addition, we studied a newly developed quasi-monochromatic source generated by converting broadband X-rays to monochromatic K α and β X-rays with a zirconium target (Z = 40). We will further study how these K α and K β dominated spectra can be implemented in conjunction with nanoparticles for targeted therapy. Acknowledgement: Ohio Supercomputer Center, Columbus, OH.

  18. Radiation incident in oil well logging

    International Nuclear Information System (INIS)

    Lozada, J.A.

    1998-01-01

    On June 4th 1997 equipment failure and violation of approved procedures by a crew of workers initiated a series of events that resulted in the unnecessary exposure to neutron and gamma radiation, from a 666 GBq Am 241 Be source, of forty two workers from a well logging company in Venezuela. Due to the presence of dry mud or drilling fluids inside the logging tool, the nosepiece was screwed off the rest of the source holder; this piece was mistaken for the entire source holder thus leaving the source inside the tool. The tool was labelled for maintenance and electronic laboratory personal worked near the source for seven hours before they identify its presence. As soon as the incident was detected a contingency plan was implemented and the source could be retrieved from the tool and placed in its shipping container. The TLD badges indicate doses well below the annual limit of 20 mSv, and none of the workers involved in the incident seem to show serious health consequences from it. After the incident, in order to avoid the occurrence of similar situations, a better source and tool maintenance program was implemented, all the workers were re-trained, and area monitors were installed in all operations bases. (author)

  19. Absorption coefficient measurrement of monochromatized synchrotron radiation at 0.65 - 1.3 A interval for some biological objects

    International Nuclear Information System (INIS)

    Avakian, Ts.M.; Karabekov, I.P.; Martirossian, M.A.

    1977-01-01

    The results of the measurement of absorption coefficients for some biological objects such as pea (Pissum sativum), wheat (Triticum aestivum), tobacco (Nicotiana-tabacum-α) seeds, as well as the distilled water are presented. The measurement has been carried out on the Erevan Physical Institute Electron Accelerator synchrotron radiation beam. The good agreement of experimental and calculated data for water confirms the accuracy of the results related to other objects

  20. Mutation induction by and mutational interaction between monochromatic wavelength radiations in the near-ultraviolet and visible ranges

    International Nuclear Information System (INIS)

    Tyrrell, R.M.

    1980-01-01

    The induction of mutations (reversion to tryptophan independence) by various UV (254, 313, 334 and 365 nm) and visible (405 and 434 nm) wavelengths was measured in exponential phase populations of Escherichia coli B/r thy trp and B/r thy trp uvr A by assay of irradiated populations on semi-enriched media. No mutations were induced in the repair proficient strain at wavelengths longer than 313 nm. Mutations were induced to the excisionless strain at wavelengths as long as 405 nm but less than expected from the known amount of DNA damage induced. Irradiation at the long wavelenths (434, 405, 365 and 334 nm) suppressed the appearance of 254- or 313 nm-induced mutations in the repair competent strain but not in the excision deficient strain. The relative dose-requirement for mutation suppression was related to the relative efficiency of these wavelengths in inducing growth delay. These results suggest that the growth delay induced by near-UV and visible wavelenghts allows more time for the 'error-free' excision repair process to act on the potentially mutagenic lesions induced by 254- and 313-nm radiations, thereby reducing the mutation frequency observed in the repair-proficient strain. The level of near-UV mutation induced in the excision deficient strain is lower than expected from the DNA damage known to be induced. It is possible that near-UV radiation induces a class of lethal lesions that are not susceptible to error-prone repair. (author)

  1. Discriminating electromagnetic radiation based on angle of incidence

    Science.gov (United States)

    Hamam, Rafif E.; Bermel, Peter; Celanovic, Ivan; Soljacic, Marin; Yeng, Adrian Y. X.; Ghebrebrhan, Michael; Joannopoulos, John D.

    2015-06-16

    The present invention provides systems, articles, and methods for discriminating electromagnetic radiation based upon the angle of incidence of the electromagnetic radiation. In some cases, the materials and systems described herein can be capable of inhibiting reflection of electromagnetic radiation (e.g., the materials and systems can be capable of transmitting and/or absorbing electromagnetic radiation) within a given range of angles of incidence at a first incident surface, while substantially reflecting electromagnetic radiation outside the range of angles of incidence at a second incident surface (which can be the same as or different from the first incident surface). A photonic material comprising a plurality of periodically occurring separate domains can be used, in some cases, to selectively transmit and/or selectively absorb one portion of incoming electromagnetic radiation while reflecting another portion of incoming electromagnetic radiation, based upon the angle of incidence. In some embodiments, one domain of the photonic material can include an isotropic dielectric function, while another domain of the photonic material can include an anisotropic dielectric function. In some instances, one domain of the photonic material can include an isotropic magnetic permeability, while another domain of the photonic material can include an anisotropic magnetic permeability. In some embodiments, non-photonic materials (e.g., materials with relatively large scale features) can be used to selectively absorb incoming electromagnetic radiation based on angle of incidence.

  2. Oxygen-independent inactivation of Haemophilus influenzae transforming DNA by monochromatic radiation: action spectrum, effect of histidine and repair

    Energy Technology Data Exchange (ETDEWEB)

    Cabrera-Juarez, E; Setlow, J K; Swenson, P A; Peak, M J

    1976-01-01

    The action spectrum for the oxygen-independent inactivation of native transforming DNA from Haemophilus influenzae with near-uv radiation revealed a shoulder beginning at 334 and extending to 460 nm. The presence of 0.2 M histidine during irradiation produced a small increase in inactivation at 254, 290 and 313 nm, a large increase at 334 nm and a decrease in inactivation at 365, 405, and 460 nm. Photoreactivation did not reverse the DNA damage produced at pH 7.0 at 334, 365, 405 and 460 nm, but did reactivate the DNA after irradiation at 254, 290 and 313 nm. The inactivation of DNA irradiated at 254, 290 and 313 nm was considerably greater when the transforming ability was assayed in an excision-defective mutant compared with the wild type, although DNA irradiated at 334, 365, 405 and 460 nm showed smaller differences. These results suggest that the oxygen-independent inactivation of H. influenzae DNA at pH 7 by irradiation at 334, 365, 405 and 460 nm is caused by lesions other than pyrimidine dimers.

  3. Photoelectron and Auger-electron spectra of Cl{sub 3}SiSi(CH{sub 3}){sub 3} obtained by using monochromatized synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Shin-ichi, E-mail: nagaoka@ehime-u.ac.jp [Department of Chemistry, Faculty of Science and Graduate School of Science and Engineering, Ehime University, Matsuyama 790-8577 (Japan); Endo, Hikaru; Nagai, Kanae [Department of Chemistry, Faculty of Science and Graduate School of Science and Engineering, Ehime University, Matsuyama 790-8577 (Japan); Takahashi, Osamu [Institute for Sustainable Sciences and Development, Hiroshima University, Higashi-Hiroshima 739-8511 (Japan); Tamenori, Yusuke [Synchrotron Radiation Research Institute/SPring-8, 1-1-1 Kouto, Sayo-cho, Sayo-gun 679-5198 (Japan); Suzuki, Isao H. [Institute of Materials Structure Science, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba 305-0801 (Japan); Advanced Institute of Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba 305-8568 (Japan)

    2014-08-15

    Highlights: • Various photo- and Auger-electron spectra of Cl{sub 3}SiSi(CH{sub 3}){sub 3} vapor were measured. • The measured spectra were interpreted with the aid of some calculations. • The spectra showed profiles close to those expected from SiCl{sub 4} and Si(CH{sub 3}){sub 4}. • These results were discussed in conjunction with site-specific fragmentation. - Abstract: A variety of photoelectron and Auger-electron spectra of 1,1,1-trimethyltrichlorodisilane vapor (Cl{sub 3}SiSi(CH{sub 3}){sub 3}) were measured by using monochromatized synchrotron radiation and a hemispherical electron energy analyzer. The measured spectra were interpreted with the aid of some calculations by means of the outer valence Green's function (OVGF) method or the density-functional-theory (DFT) method. Since Cl{sub 3}SiSi(CH{sub 3}){sub 3} consists of -SiCl{sub 3} and -Si(CH{sub 3}){sub 3} moieties, the experimental core-electron binding-energies were compared with those of tetrachlorosilane and tetramethylsilane (SiCl{sub 4} and Si(CH{sub 3}){sub 4}, respectively). This comparison showed that electronic properties of Cl{sub 3}SiSi(CH{sub 3}){sub 3} hold a close correlation with those of SiCl{sub 4} and Si(CH{sub 3}){sub 4}. Si:L{sub 23}VV, Cl:L{sub 23}VV and C:KVV Auger-electron spectra of Cl{sub 3}SiSi(CH{sub 3}){sub 3} also showed profiles close to those expected from the spectra of SiCl{sub 4} and Si(CH{sub 3}){sub 4}. The results obtained here were discussed in conjunction with electronic relaxation leading to site-specific fragmentation.

  4. Prostate cancer incidence in Australia correlates inversely with solar radiation.

    Science.gov (United States)

    Loke, Tim W; Seyfi, Doruk; Sevfi, Doruk; Khadra, Mohamed

    2011-11-01

    What's known on the subject? and What does the study add? Increased sun exposure and blood levels of vitamin D have been postulated to be protective against prostate cancer. This is controversial. We investigated the relationship between prostate cancer incidence and solar radiation in non-urban Australia, and found a lower incidence in regions receiving more sunlight. In landmark ecological studies, prostate cancer mortality rates have been shown to be inversely related to ultraviolet radiation exposure. Investigators have hypothesised that ultraviolet radiation acts by increasing production of vitamin D, which inhibits prostate cancer cells in vitro. However, analyses of serum levels of vitamin D in men with prostate cancer have failed to support this hypothesis. This study has found an inverse correlation between solar radiation and prostate cancer incidence in Australia. Our population (previously unstudied) represents the third group to exhibit this correlation. Significantly, the demographics and climate of Australia differ markedly from those of previous studies conducted on men in the United Kingdom and the United States. • To ascertain if prostate cancer incidence rates correlate with solar radiation among non-urban populations of men in Australia. • Local government areas from each state and territory were selected using explicit criteria. Urban areas were excluded from analysis. • For each local government area, prostate cancer incidence rates and averaged long-term solar radiation were obtained. • The strength of the association between prostate cancer incidence and solar radiation was determined. • Among 70 local government areas of Australia, age-standardized prostate cancer incidence rates for the period 1998-2007 correlated inversely with daily solar radiation averaged over the last two decades. •  There exists an association between less solar radiation and higher prostate cancer incidence in Australia. © 2011 THE AUTHORS. BJU

  5. Monochromatic neutrino beams

    International Nuclear Information System (INIS)

    Bernabeu, Jose; Burguet-Castell, Jordi; Espinoza, Catalina; Lindroos, Mats

    2005-01-01

    In the last few years spectacular results have been achieved with the demonstration of non vanishing neutrino masses and flavour mixing. The ultimate goal is the understanding of the origin of these properties from new physics. In this road, the last unknown mixing [U e3 ] must be determined. If it is proved to be non-zero, the possibility is open for Charge Conjugation-Parity (CP) violation in the lepton sector. This will require precision experiments with a very intense neutrino source. Here a novel method to create a monochromatic neutrino beam, an old dream for neutrino physics, is proposed based on the recent discovery of nuclei that decay fast through electron capture. Such nuclei will generate a monochromatic directional neutrino beam when decaying at high energy in a storage ring with long straight sections. We also show that the capacity of such a facility to discover new physics is impressive, so that fine tuning of the boosted neutrino energy allows precision measurements of the oscillation parameters even for a [U e3 ] mixing as small as 1 degree. We can thus open a window to the discovery of CP violation in neutrino oscillations

  6. Radiation produced by electrons incident on molecules

    International Nuclear Information System (INIS)

    Moehlman, G.R.

    1977-01-01

    The work described in this thesis deals with light intensity measurements of emission spectra (1850-9000 A) produced by a continuous or pulsed beam of monoenergetic electrons (0 - 2000 eV) incident on a variety of molecular gases like H 2 , D 2 , H 2 O, HCl, NH 3 and several hydrocarbons. The emission spectra are dominated by fluorescence from excited fragments produced via dissociative excitation, besides fluorescence from excited parent molecules themselves. The experimental results thus obtained are expressed in terms of emission cross sections and lifetimes

  7. IRID: specifications for the Ionising Radiations Incident Database

    International Nuclear Information System (INIS)

    Thomas, G.O.; Croft, J.R.; Williams, M.K.; McHugh, J.O.

    1996-01-01

    Technologies that make use of ionising radiations are widespread. They provide many benefits but, as with other technologies, the use of ionising radiations carries with it the potential for incidents and accidents. Their severity can vary from the trivial to the fatal and may involve substantial economic penalties. In order to minimise the number of incidents and their consequences it is important that there is a mechanism to learn the lessons from those that do occur. To help pursue this objective the National Radiological Protection Board, the Health and Safety Executive and the Environment Agency have established a national Ionising Radiations Incident Database (IRID) to cover radiation incidents in industry, medicine, research and teaching. This publication details the specifications for IRID and its methods of operation. All information in the database will be unattributable and names of persons or organisations will not be included. It is a personal computer based system with 24 fields to categorise an incident, including a text field that will provide a description of the incident giving the causes, consequences, follow-up actions and lessons to be learned. These descriptions will be used in subsequent publications to provide feedback to the users. (UK)

  8. The management of radiation treatment error through incident learning

    International Nuclear Information System (INIS)

    Clark, Brenda G.; Brown, Robert J.; Ploquin, Jodi L.; Kind, Anneke L.; Grimard, Laval

    2010-01-01

    Purpose: To assess efficacy of an incident learning system in the management of error in radiation treatment. Materials and methods: We report an incident learning system implementation customized for radiation therapy where any 'unwanted or unexpected change from normal system behaviour that causes or has the potential to cause an adverse effect to persons or equipment' is reported, investigated and learned from. This system thus captures near-miss (potential) and actual events. Incidents are categorized according to severity, type and origin. Results: Our analysis spans a period of 3 years with an average accrual of 11.6 incidents per week. We found a significant reduction in actual incidents of 28% and 47% in the second and third year when compared to the first year (p < 0.001), which we attribute to the many interventions prompted by the analysis of incidents reported. We also saw a similar significant reduction in incidents generated at the treatment unit correlating with the introduction of direct treatment parameter transfer and electronic imaging (p < 0.001). Conclusions: Implementation of an incident learning system has helped us to establish a just environment where all staff members report deviations from normal system behaviour and thus generate evidence to initiate safety improvements.

  9. Radiation protection aspects of the incident recovery

    International Nuclear Information System (INIS)

    Tibor, Bujtas; Arpad, Nenyei

    2006-01-01

    On the 10. April 2003 a serious accident occurred at PAKS nuclear power plant. The cleaning of fuel assemblies unloaded from the reactor of unit 2 was commencing under water in the fuel-cleaning equipment in the maintenance shaft number 1. There was no chain reaction in the cleaning tank but the fission products, accumulated in the previous operational time still produced a significant heat. Due to the inadequate cooling of the cleaning tank the assemblies overheated within a few hours. After opening the lid of the tank the entering cold water caused thermal shock and significant damage to the fuel assemblies. cladding of the fuel elements opened up and the uranium dioxide pellets got also damaged. The removal of the damaged fuel assemblies and the released debris must be managed. There are technical difficulties and radiation protection problems to reduce the radiation exposure of the workers as well as the minimization of the radioactive materials released into the environment. The description of the situation and the different actions are detailed. (N.C.)

  10. Ascertaining directionality information from incident nuclear radiation

    Energy Technology Data Exchange (ETDEWEB)

    Archambault, Brian C. [Purdue University (United States); Lapinskas, Joseph R. [QSA Global, Inc. (United States); Wang Jing; Webster, Jeffrey A. [Purdue University (United States); McDeavitt, Sean [Texas A and M University (United States); Taleyarkhan, Rusi P., E-mail: rusi@purdue.edu [Purdue University (United States)

    2011-10-15

    Highlights: > Use of tensioned metastable fluids for detection of fast neutron radiation. > Monitored neutrons with 100% gamma photon blindness capability. > Monitored direction of incoming neutron radiation from special nuclear material emissions. > Ascertained directionality of neutron source to within 30 deg. and with 80% confidence with 2000 detection events at rate of 30-40 per second. > Conducted successful blind test for determining source of neutrons from a hidden neutron emitting source. > Compared results with MCNP5-COMSOL based multi-physics model. - Abstract: Unprecedented capabilities for the detection of nuclear particles via tailored resonant acoustic systems such as the acoustic tensioned metastable fluid detection (ATMFD) systems were assessed for determining directionality of incoming fast neutrons. This paper presents advancements that expand on these accomplishments, thereby increasing the accuracy and precision of ascertaining directionality information utilizing enhanced signal processing-cum-signal analysis, refined computational algorithms, and on demand enlargement of the detector sensitive volume. Advances in the development of ATMFD systems were accomplished utilizing a combination of experimentation and theoretical modeling. Modeling methodologies include Monte-Carlo based nuclear particle transport using MCNP5 and multi-physics based assessments accounting for acoustic, structural, and electromagnetic coupling of the ATMFD system via COMSOL's multi-physics simulation platform. Benchmarking and qualification studies have been conducted with a 1 Ci Pu-Be neutron-gamma source. These results show that the specific ATMFD system used for this study can enable detection of directionality of incoming fast neutrons from the neutron source to within 30{sup o} with 80% confidence; this required {approx}2000 detection events which could be collected within {approx}50 s at a detection rate of {approx}30-40 per second. Blind testing was

  11. Ascertaining directionality information from incident nuclear radiation

    International Nuclear Information System (INIS)

    Archambault, Brian C.; Lapinskas, Joseph R.; Wang Jing; Webster, Jeffrey A.; McDeavitt, Sean; Taleyarkhan, Rusi P.

    2011-01-01

    Highlights: → Use of tensioned metastable fluids for detection of fast neutron radiation. → Monitored neutrons with 100% gamma photon blindness capability. → Monitored direction of incoming neutron radiation from special nuclear material emissions. → Ascertained directionality of neutron source to within 30 deg. and with 80% confidence with 2000 detection events at rate of 30-40 per second. → Conducted successful blind test for determining source of neutrons from a hidden neutron emitting source. → Compared results with MCNP5-COMSOL based multi-physics model. - Abstract: Unprecedented capabilities for the detection of nuclear particles via tailored resonant acoustic systems such as the acoustic tensioned metastable fluid detection (ATMFD) systems were assessed for determining directionality of incoming fast neutrons. This paper presents advancements that expand on these accomplishments, thereby increasing the accuracy and precision of ascertaining directionality information utilizing enhanced signal processing-cum-signal analysis, refined computational algorithms, and on demand enlargement of the detector sensitive volume. Advances in the development of ATMFD systems were accomplished utilizing a combination of experimentation and theoretical modeling. Modeling methodologies include Monte-Carlo based nuclear particle transport using MCNP5 and multi-physics based assessments accounting for acoustic, structural, and electromagnetic coupling of the ATMFD system via COMSOL's multi-physics simulation platform. Benchmarking and qualification studies have been conducted with a 1 Ci Pu-Be neutron-gamma source. These results show that the specific ATMFD system used for this study can enable detection of directionality of incoming fast neutrons from the neutron source to within 30 o with 80% confidence; this required ∼2000 detection events which could be collected within ∼50 s at a detection rate of ∼30-40 per second. Blind testing was successfully

  12. Environmental exposure to ionizing radiation and childhood leukaemia incidence

    International Nuclear Information System (INIS)

    Evrard, Anne-Sophie

    2006-01-01

    This thesis aimed at providing an epidemiological approach of the hypothesis of the existence of an association between environmental exposure to ionizing radiation and childhood leukaemia incidence. From 1990 to 2001, 5,330 cases of acute leukaemia were registered by the French National Registry of Childhood Leukemia and Lymphoma in children under 15 years of age and living in mainland France at the time of diagnosis. Indoor radon concentration was estimated using 13,240 measurements carried out by the Institute for Radiation Protection and Nuclear Safety (IRSN), and covering the whole country. Exposure to terrestrial gamma radiation was based on continuous measurements, using thermoluminescent dosimeters, at about 1,000 sites covering the whole of France, in order to monitor the level of environmental radioactivity in France. Analyses were conducted using Poisson regressions, including ecological co-variates, at the level of the 'Departments' (95 administrative geographical units in France). A significant positive ecological association between indoor radon concentration and the incidence of acute myeloid leukaemia was evidenced (SIR=1.19 per 100 Bq/m 3 - 95% confidence interval=[1.03-1.38]) and remained significant in multivariate regression analyses including exposure to terrestrial gamma radiation and/or some ecological co-variates. Conversely, there was no evidence of an ecological association between exposure to terrestrial gamma radiation and childhood leukaemia incidence. The epidemiological studies of the incidence of childhood leukaemia around nuclear sites analyzed incidence with respect to the distance from the plants, without considering any information on the levels or geographic distribution of the radiation dose due to discharges from the plants. The present study investigated for the first time the incidence of childhood leukaemia around French nuclear installations using a geographic zoning based on estimated doses due to gaseous

  13. Medical management of three workers following a radiation exposure incident

    International Nuclear Information System (INIS)

    House, R.A.; Sax, S.E.; Rumack, E.R.; Holness, D.L.

    1992-01-01

    The medical management of three individuals involved in an exposure incident to whole-body radiation at a nuclear generating plant of a Canadian electrical utility is described. The exposure incident resulted in the two highest whole-body radiation doses ever received in a single event by workers in a Canadian nuclear power plant. The individual whole-body doses (127.4 mSv, 92.0 mSv, 22.4 mSv) were below the threshold for acute radiation sickness but the exposures still presented medical management problems related to assessment and counseling. Serial blood counting and lymphocyte cytogenetic analysis to corroborate the physical dosimetry were performed. All three employees experienced somatic symptoms due to stress and one employee developed post-traumatic stress disorder. This incident indicates that there is a need in such radiation exposure accidents for early and continued counseling of exposed employees to minimize the risk of development of stress-related symptoms

  14. Medical management of three workers following a radiation exposure incident

    Energy Technology Data Exchange (ETDEWEB)

    House, R.A.; Sax, S.E.; Rumack, E.R.; Holness, D.L. (Department of Occupational and Environmental Health, St. Michael' s Hospital, Toronto, Ontario (Canada))

    1992-01-01

    The medical management of three individuals involved in an exposure incident to whole-body radiation at a nuclear generating plant of a Canadian electrical utility is described. The exposure incident resulted in the two highest whole-body radiation doses ever received in a single event by workers in a Canadian nuclear power plant. The individual whole-body doses (127.4 mSv, 92.0 mSv, 22.4 mSv) were below the threshold for acute radiation sickness but the exposures still presented medical management problems related to assessment and counseling. Serial blood counting and lymphocyte cytogenetic analysis to corroborate the physical dosimetry were performed. All three employees experienced somatic symptoms due to stress and one employee developed post-traumatic stress disorder. This incident indicates that there is a need in such radiation exposure accidents for early and continued counseling of exposed employees to minimize the risk of development of stress-related symptoms.

  15. Phenomenological modelling of second cancer incidence for radiation treatment planning

    International Nuclear Information System (INIS)

    Pfaffenberger, Asja; Oelfke, Uwe; Schneider, Uwe; Poppe, Bjoern

    2009-01-01

    It is still an unanswered question whether a relatively low dose of radiation to a large volume or a higher dose to a small volume produces the higher cancer incidence. This is of interest in view of modalities like IMRT or rotation therapy where high conformity to the target volume is achieved at the cost of a large volume of normal tissue exposed to radiation. Knowledge of the shape of the dose response for radiation-induced cancer is essential to answer the question of what risk of second cancer incidence is implied by which treatment modality. This study therefore models the dose response for radiation-induced second cancer after radiation therapy of which the exact mechanisms are still unknown. A second cancer risk estimation tool for treatment planning is presented which has the potential to be used for comparison of different treatment modalities, and risk is estimated on a voxel basis for different organs in two case studies. The presented phenomenological model summarises the impact of microscopic biological processes into effective parameters of mutation and cell sterilisation. In contrast to other models, the effective radiosensitivities of mutated and non-mutated cells are allowed to differ. Based on the number of mutated cells present after irradiation, the model is then linked to macroscopic incidence by summarising model parameters and modifying factors into natural cancer incidence and the dose response in the lower-dose region. It was found that all principal dose-response functions discussed in the literature can be derived from the model. However, from the investigation and due to scarcity of adequate data, rather vague statements about likelihood of dose-response functions can be made than a definite decision for one response. Based on the predicted model parameters, the linear response can probably be rejected using the dynamics described, but both a flattening response and a decrease appear likely, depending strongly on the effective cell

  16. Simulating Space Radiation-Induced Breast Tumor Incidence Using Automata.

    Science.gov (United States)

    Heuskin, A C; Osseiran, A I; Tang, J; Costes, S V

    2016-07-01

    Estimating cancer risk from space radiation has been an ongoing challenge for decades primarily because most of the reported epidemiological data on radiation-induced risks are derived from studies of atomic bomb survivors who were exposed to an acute dose of gamma rays instead of chronic high-LET cosmic radiation. In this study, we introduce a formalism using cellular automata to model the long-term effects of ionizing radiation in human breast for different radiation qualities. We first validated and tuned parameters for an automata-based two-stage clonal expansion model simulating the age dependence of spontaneous breast cancer incidence in an unexposed U.S. We then tested the impact of radiation perturbation in the model by modifying parameters to reflect both targeted and nontargeted radiation effects. Targeted effects (TE) reflect the immediate impact of radiation on a cell's DNA with classic end points being gene mutations and cell death. They are well known and are directly derived from experimental data. In contrast, nontargeted effects (NTE) are persistent and affect both damaged and undamaged cells, are nonlinear with dose and are not well characterized in the literature. In this study, we introduced TE in our model and compared predictions against epidemiologic data of the atomic bomb survivor cohort. TE alone are not sufficient for inducing enough cancer. NTE independent of dose and lasting ∼100 days postirradiation need to be added to accurately predict dose dependence of breast cancer induced by gamma rays. Finally, by integrating experimental relative biological effectiveness (RBE) for TE and keeping NTE (i.e., radiation-induced genomic instability) constant with dose and LET, the model predicts that RBE for breast cancer induced by cosmic radiation would be maximum at 220 keV/μm. This approach lays the groundwork for further investigation into the impact of chronic low-dose exposure, inter-individual variation and more complex space radiation

  17. Learning from radiation incidents: the new OTHEA website

    International Nuclear Information System (INIS)

    Shaw, P V; Ely, S Y; Croueail, P; Bataille, C

    2010-01-01

    OTHEA is the name of a new website (www.othea.net), created by the Health Protection Agency (UK) and the Centre d'etude sur l'evaluation de la protection dans le domaine nucleaire (CEPN, France), and supported by several other stakeholders including national societies and associations. The website is bi-lingual (French and English) and the purpose is to share the lessons learnt from radiological incidents that have occurred in the industrial, medical, research and teaching, and other non-nuclear sectors. OTHEA contains a collection of incident reports, categorised according to the sector and the type of application, and a search facility. The reports can be freely downloaded and printed, for example for use in radiation protection training activities. To encourage dissemination, the incident reports have been made anonymous, i.e. any information that could identify a particular individual, organisation or site has been removed. Each report contains a brief summary of the incident, the radiological consequences, and the lessons learnt. The aim is not to capture every single incident, but to provide a range of reports selected according to the value of the lessons learnt. For OTHEA to be a long-term success, it needs to be sustained with new reports. Therefore users are encouraged to submit incident reports that can be considered for inclusion in OTHEA. This note summarises the background to OTHEA, and provides a description of the operating features and content at its launch in summer 2010. (note)

  18. Radiation incidents with a cobalt-60 teletherapy unit

    Energy Technology Data Exchange (ETDEWEB)

    Lane, R G; Tolbert, D D; Pailwal, B R; Radtke, R R [Wisconsin Univ., Madison (USA). Dept. of Radiology

    1976-08-01

    Three radiation incidents associated with source drive failures on one particular /sup 60/Co teletherapy unit, which took place during a single year's operation, are discussed. In each case the extra treatment time of the patient, the exposure to the technician, the cause of the breakdown and the subsequent action taken are detailed. Recommendations for users of /sup 60/Co teletherapy units to minimise the results of the malfunctioning of such a system are given.

  19. Radiation incidents with a cobalt-60 teletherapy unit

    International Nuclear Information System (INIS)

    Lane, R.G.; Tolbert, D.D.; Pailwal, B.R.; Radtke, R.R.

    1976-01-01

    Three radiation incidents associated with source drive failures on one particular 60 Co teletherapy unit, which took place during a single year's operation, are discussed. In each case the extra treatment time of the patient, the exposure to the technician, the cause of the breakdown and the subsequent action taken are detailed. Recommendations for users of 60 Co teletherapy units to minimise the results of the malfunctioning of such a system are given. (U.K.)

  20. Influence of radiation and non-radiation factors on pancreatic cancer incidence among Mayak PA workers

    Energy Technology Data Exchange (ETDEWEB)

    Zhuntova, G.V.; Tokarskaya, Z.B.; Belyaeva, Z.D. [Southern Ural Biophysics Institute (SUBI), Ozyorsk (Russian Federation); Syrchikov, V.A.; Grigoryeva, E.S. [Mayak Production Association (Mayak PA), Ozyorsk (Russian Federation)

    2006-07-01

    The finding of this nested case-control study suggests that high levels of 239 Pu incorporation (239 Pu body burden > 3.7), alcohol abuse and smoking were associated with increasing the risk of pancreatic cancer among Mayak PA workers chronically exposed to ionizing radiation. The contribution of non radiation factors (alcohol abuse and smoking) to pancreatic tumor incidence is greater (AR=51%) than 239 Pu incorporation kBq; AR = 7%). No significant effect of external gamma rays ({<=} 6.8 Gy), prior exposure to chemical agents, or chronic digestive diseases was found on the incidence of pancreatic tumor. Evaluation of the absorbed alpha-radiation pancreatic dose will permit to make more exact the 239 Pu risk estimation in the further extended study.

  1. Influence of radiation and non-radiation factors on pancreatic cancer incidence among Mayak PA workers

    International Nuclear Information System (INIS)

    Zhuntova, G.V.; Tokarskaya, Z.B.; Belyaeva, Z.D.; Syrchikov, V.A.; Grigoryeva, E.S.

    2006-01-01

    The finding of this nested case-control study suggests that high levels of 239 Pu incorporation (239 Pu body burden > 3.7), alcohol abuse and smoking were associated with increasing the risk of pancreatic cancer among Mayak PA workers chronically exposed to ionizing radiation. The contribution of non radiation factors (alcohol abuse and smoking) to pancreatic tumor incidence is greater (AR=51%) than 239 Pu incorporation kBq; AR = 7%). No significant effect of external gamma rays (≤ 6.8 Gy), prior exposure to chemical agents, or chronic digestive diseases was found on the incidence of pancreatic tumor. Evaluation of the absorbed alpha-radiation pancreatic dose will permit to make more exact the 239 Pu risk estimation in the further extended study

  2. Lessons Learnt from Past Incidents and Accidents in Radiation Oncology.

    Science.gov (United States)

    Knöös, T

    2017-09-01

    The purpose of this report is to review and compile what have been and can be learnt from incidents and accidents in radiation oncology, especially in external beam and brachytherapy. Some major accidents from the last 20 years will be discussed. The relationship between major events and minor or so-called near misses is mentioned, leading to the next topic of exploring the knowledge hidden among them. The main lessons learnt from the discussion here and elsewhere are that a well-functioning and safe radiotherapy department should help staff to work with awareness and alertness and that documentation and procedures should be in place and known by everyone. It also requires that trained and educated staff with the required competences are in place and, finally, functions and responsibilities are defined and well known. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  3. Using mortality data to estimate radiation effects on breast cancer incidence

    International Nuclear Information System (INIS)

    Hoel, D.G.; Dinse, G.E.

    1990-01-01

    In this paper we combine Japanese data on radiation exposure and cancer mortality with U.S. data on cancer incidence and lethality to estimate the effects of ionizing radiation on cancer incidence. The analysis is based on the mathematical relationship between the mortality rate and the incidence and lethality rates, as well as on statistical models that relate Japanese incidence rates to U.S. incidence rates and radiation risk factors. Our approach assumes that the risk of death from causes other than the cancer does not depend on whether or not the cancer is present, and among individuals with the cancer, the risk of death attributable to the cancer is the same in Japan and the U.S. and is not affected by radiation exposure. In particular, we focus on the incidence of breast cancer in Japanese women and how this incidence is affected by radiation risk factors. The analysis uses Japanese exposure and mortality data from the Radiation Effects Research Foundation study of atomic bomb survivors and U.S. incidence and lethality data from the Surveillance, Epidemiology, and End Results Registry. Even without Japanese incidence data, we obtain reasonable estimates of the incidence of breast cancer in unexposed Japanese women and identify the radiation risk factors that affect this incidence. Our analysis demonstrates that the age at exposure is an important risk factor, but that the incidence of breast cancer is not affected by the city of residence (Nagasaki versus Hiroshima) or the time since exposure

  4. Alteration in murine epidermal Langerhans cell population by various UV irradiations: quantitative and morphologic studies on the effects of various wavelengths of monochromatic radiation on Ia-bearing cells

    International Nuclear Information System (INIS)

    Obata, M.; Tagami, H.

    1985-01-01

    The present study was undertaken in order to clarify the exact mode of the Langerhans cell (LC) depleting process caused by UV irradiation. Following irradiation with a single dose of various wavelengths of monochromatic UV radiation (UVR), the number of Ia-positive cells were studied in mouse epidermal sheets quantitatively, particularly with regard to dose-response relationships, action spectrum, and time course change. In addition, morphologic alterations of these cells were studied using electron- and immunoelectron microscopy (EM and IEM). The authors obtained the following results after a single dose of UVB radiation (200 mJ/cm2 of 300 nm) or PUVA (1% of 8-methoxypsoralen (8-MOP) 20 microliter and 1 J/cm2 of 360 nm): (1) EM and IEM showed that while some LCs simply lost their Ia marker without any structural alterations, the majority of the LCs disappeared due to actual cell damage. (2) During an ''injury phase,'' the initial 48 h, and a ''recovery phase,'' lasting from 4-14 days after irradiation, enlargement of the size of remaining Ia-positive LCs occurred. The degree of enlargement was closely related to the degree of reduction in number, suggesting a process compensating for the loss of the LC population. (3) It was found that the recovery rate of LCs after irradiation damage was slower than that of keratinocytes, indicating different cell kinetics between these distinct cell populations in the epidermis, i.e., restoration of LCs after irradiation seems to be achieved at least partially through a repopulation process originating in the bone marrow

  5. Dependence of extinction cross-section on incident polarization state and particle orientation

    International Nuclear Information System (INIS)

    Yang Ping; Wendisch, Manfred; Bi Lei; Kattawar, George; Mishchenko, Michael; Hu, Yongxiang

    2011-01-01

    This note reports on the effects of the polarization state of an incident quasi-monochromatic parallel beam of radiation and the orientation of a hexagonal ice particle with respect to the incident direction on the extinction process. When the incident beam is aligned with the six-fold rotational symmetry axis, the extinction is independent of the polarization state of the incident light. For other orientations, the extinction cross-section for linearly polarized light can be either larger or smaller than its counterpart for an unpolarized incident beam. Therefore, the attenuation of a quasi-monochromatic radiation beam by an ice cloud depends on the polarization state of the beam if ice crystals within the cloud are not randomly oriented. Furthermore, a case study of the extinction of light by a quartz particle is also presented to illustrate the dependence of the extinction cross-section on the polarization state of the incident light.

  6. Modification of radiation-induced murine thymic lymphoma incidence by curcumin

    International Nuclear Information System (INIS)

    Dange, P.S.; Yadav, H.D.; Kumar, Vimalesh; Bhilwade, H.N.; Pandey, B.N.; Sarma, H.D.

    2017-01-01

    Curcumin is a known antioxidant, preventing radiation damage including carcinogenesis. However, concentration and feeding schedule of curcumin in modification of radiation induced thymic lymphoma incidence in vivo model has not been studied. We report here modification of incidence of γ-radiation-induced thymic lymphoma in mice fed with different doses of curcumin (0.05 to 1 %) in diet. Results: Female Swiss mice (6-8 weeks) fed with normal diet and exposed to 3 Gy whole body "6"0Co γ-irradiation (WBI) showed 85 % incidence of thymic lymphoma (TL) at 120 days post-irradiation. A concentration of 1 % curcumin was found the most effective in TL incidence prevention than other fed concentrations. The TL incidence was remarkably reduced when curcumin was fed to the mice before than after the radiation exposure. These results suggest modification of TL incidence by curcumin in irradiated mice involving DNA damage and apoptotic death mechanisms

  7. Analysis of a radiation incident with intraoral dental radiological equipment

    International Nuclear Information System (INIS)

    Malone, J.F.

    1996-01-01

    A case is described involving a serious incident with dental radiological equipment, containing many lessons that may be applied to the preparation of other cases. The description includes an account of the incident, the circumstances surrounding it, the dosimetry, risk estimates and the medical consequences of the incident. In addition, some aspects of the associated legal proceedings are reviewed and assessed. As a result of the incident described, a number of conclusions are drawn with respect to important practices in ensuring the safety of installations and the value of evidence brought forward by expert witnesses. (author)

  8. Electromagnetic Radiation of Electrons in Periodic Structures

    CERN Document Server

    Potylitsyn, Alexander Petrovich

    2011-01-01

    Periodic magnetic structures (undulators) are widely used in accelerators to generate monochromatic undulator radiation (UR) in the range from far infrared to the hard X-ray region. Another periodic crystalline structure is used to produce quasimonochromatic polarized photon beams via the coherent bremsstrahlung mechanism (CBS). Due to such characteristics as monochromaticity, polarization and adjustability, these types of radiation is of large interest for applied and basic research of accelerator-emitted radiation. The book provides a detailed overview of the fundamental principles behind electromagnetic radiation emitted from accelerated charged particles (e.g. UR, CBS, radiation of fast electrons in Laser flash fields) as well as a unified description of relatively new radiation mechanisms which attracted great interest in recent years. This are the so-called polarization radiation excited by the Coulomb field of incident particles in periodic structures, parametric X-rays, resonant transition radiation a...

  9. Simulation of Solar Radiation Incident on Horizontal and Inclined Surfaces

    Directory of Open Access Journals (Sweden)

    MA Basunia

    2012-12-01

    Full Text Available A computer model was developed to simulate the hourly, daily and monthly average of daily solar radiation on horizontal and inclined surfaces. The measured hourly and daily solar radiation was compared with simulated radiation, and favourable agreement was observed for the measured and predicted values on clear days. The measured and simulated monthly averages of total (diffuse and beam daily solar radiation were compared and a reasonable agreement was observed for a number of stations in Japan. The simulation showed that during the rice harvesting season, September to October, there is a daily average of 14.7 MJ/m2 of solar irradiation on a horizontal surface in Matsuyama, Japan. There is a similar amount of solar radiation on a horizontal surface during the major rice harvesting season, November to December, in Bangladesh. This radiation can be effectively utilized for drying rough rice and other farm crops.

  10. Monochromatic x-rays for low-dose digital mammography: preliminary results.

    Science.gov (United States)

    Yoon, Kwon-Ha; Kwon, Young Man; Choi, Byoung-Jung; Son, Hyun Hwa; Ryu, Cheol Woo; Chon, Kwon Su; Park, Seong Hoon; Juhng, Sun Kwan

    2012-12-01

    The feasibility of using monochromatic x-ray imaging generated from an x-ray tube and a multilayer reflector for digital mammography with a low radiation dose was examined. A multilayer mirror was designed to select the x-ray peak with an energy of 21.5 keV generated from an x-ray tube with a tungsten target and was fabricated by the ion-beam sputtering deposition system. Monochromatic x-ray images were obtained from an experimental digital mammography setup with a scanning stage. The performance of the system was evaluated using a breast phantom, a spectrometer, and a radiation dosimeter. We measured the contrast-to-noise ratio and performed the 10% modulation function test to determine image quality and resolution. The monochromatic beam from the multilayer reflector had a full-width-at-half-maximum of 0.9 keV at 21.5 keV, and the reflectivity was 0.70, which was 90% of the designed value. The polychromatic and monochromatic x-rays showed radiation doses of 0.497 and 0.0415 mGy, respectively. The monochromatic x-ray image shows fibers, calcifications, and masses more clearly than the polychromatic x-ray images do. The image contrast of the monochromatic x-rays was 1.85 times higher than that of the polychromatic x-rays. The experimental mammography setup had a spatial resolution of 7 lp/mm with both x-rays. Monochromatic x-rays generated using a multilayer mirror may be a useful diagnostic tool for breast examination by providing high contrast imaging with a low radiation dose.

  11. The Equivalent Uniform Dose as a severity metric for radiation treatment incidents

    International Nuclear Information System (INIS)

    Dunscombe, Peter B.; Iftody, Sandra; Ploquin, Nicolas; Ekaette, Edidiong U.; Lee, Robert C.

    2007-01-01

    In allocating resources within a risk management program, ideally we would like to know both the probabilities and consequences of potential incidents. We simulate, on a treatment planning computer, several commonly reported incidents in radiation treatment and explore their consequences for the EUDs of targets and organs at risk

  12. Radiation effects in silicon and gallium arsenide solar cells using isotropic and normally incident radiation

    Science.gov (United States)

    Anspaugh, B. E.; Downing, R. G.

    1984-01-01

    Several types of silicon and gallium arsenide solar cells were irradiated with protons with energies between 50 keV and 10 MeV at both normal and isotropic incidence. Damage coefficients for maximum power relative to 10 MeV were derived for these cells for both cases of omni-directional and normal incidence. The damage coefficients for the silicon cells were found to be somewhat lower than those quoted in the Solar Cell Radiation Handbook. These values were used to compute omni-directional damage coefficients suitable for solar cells protected by coverglasses of practical thickness, which in turn were used to compute solar cell degradation in two proton-dominated orbits. In spite of the difference in the low energy proton damage coefficients, the difference between the handbook prediction and the prediction using the newly derived values was negligible. Damage coefficients for GaAs solar cells for short circuit current, open circuit voltage, and maximum power were also computed relative to 10 MeV protons. They were used to predict cell degradation in the same two orbits and in a 5600 nmi orbit. Results show the performance of the GaAs solar cells in these orbits to be superior to that of the Si cells.

  13. Gamma radiation influences postharvest disease incidence of pineapple fruits

    International Nuclear Information System (INIS)

    Damayanti, M.; Sharma, G.J.; Kundu, S.C.

    1992-01-01

    The application of gamma radiation for improving the storage of pineapple fruits [Ananas comosus (L.) Merr. cv. Queen] has been studied in an attempt to reduce decay caused by fungal pathogens such as Ceratocystis paradoxa (Dade)-Moreau and Penicillium purpurogenum Stoll. Gamma radiation at 50, 75, 100, 150, and 250 Gy improved shelf life. The maximum tolerable dose was approximately 250 Gy. Fruits irradiated with up to 150 Gy and then stored at 25 to 28C maintained their texture better than did the controls. Radiation, particularly at doses 250 Gy, caused browning of the skin and softening of tissues. Browning increased with increasing radiation dose and storage duration. Excessively high doses promoted spoilage. Doses in the range of 50 to 250 Gy, in combination with storage at 11 to 13C, can be used to reduce postharvest losses in pineapple due to fungal diseases and senescence, thereby extending shelf life

  14. An evaluation of the effect of natural background radiation on cancer incidence

    International Nuclear Information System (INIS)

    Cohen, Jerry J.

    1978-01-01

    Previous studies on the relationship between levels of natural background radiation and cancer incidence indicate no significant correlation. This observation is shown to be consistent with certain predicted effect levels of ionizing radiation on malignancy production (BEIR, ICRP). Other theoretical predictions on the effects of ionizing radiation indicate induction rates to be as high as 8 x 10 -3 cancers/person-rem. Assuming this factor were correct, then roughly one-half of the cancer incidence in the USA could be attributed to exposure to natural background radiation. By statistically testing various hypothetically assigned cancer induction rates against observed data, it is possible to develop a probabilistic perspective on the cause-effect relationship. Tests have been performed using normalized (by age, death rate, etc.) cancer incidence by state against levels of background radiation. This evaluation allows for the determination of the probability of observing the actual data given that the hypotheses were correct. Graphic relationships between hypothetically assigned radiation induced cancer rates vs. the probability of observing the actual incidence are developed and presented. It is shown that if the cancer induction rate were in excess of ∼10 -3 cancers/person-rem, it would be highly improbable that there would, in fact, be a lack of correlation between the rates of natural background radiation and cancer incidence. (author)

  15. Monochromatic X-ray probing of a superdense plasma

    International Nuclear Information System (INIS)

    Pikuz, S.A.; Shelkovenko, T.A.; Romanova, V.M.; Faenov, A.Ya.; Dyakin, V.A.; Pikuz, T.A.

    1995-01-01

    Investigation results are presented of the superdense plasma of an exploding wire by means of a new scheme of X-ray monochromatic probing. The scheme permits not only to obtain the shadow images of bright plasma objects in separate spectral lines with a high spatial resolution but and to lower requirements to a radiation source. Experimental results confirm existence of a small-dense plasma coronae, appeared during the initial stage of a discharge through a wire, and a dense core, existing at the pinch axis in the discharge process. 13 refs.; 3 figs

  16. Are passive smoking, air pollution and obesity a greater mortality risk than major radiation incidents?

    Directory of Open Access Journals (Sweden)

    Smith Jim T

    2007-04-01

    Full Text Available Abstract Background Following a nuclear incident, the communication and perception of radiation risk becomes a (perhaps the major public health issue. In response to such incidents it is therefore crucial to communicate radiation health risks in the context of other more common environmental and lifestyle risk factors. This study compares the risk of mortality from past radiation exposures (to people who survived the Hiroshima and Nagasaki atomic bombs and those exposed after the Chernobyl accident with risks arising from air pollution, obesity and passive and active smoking. Methods A comparative assessment of mortality risks from ionising radiation was carried out by estimating radiation risks for realistic exposure scenarios and assessing those risks in comparison with risks from air pollution, obesity and passive and active smoking. Results The mortality risk to populations exposed to radiation from the Chernobyl accident may be no higher than that for other more common risk factors such as air pollution or passive smoking. Radiation exposures experienced by the most exposed group of survivors of Hiroshima and Nagasaki led to an average loss of life expectancy significantly lower than that caused by severe obesity or active smoking. Conclusion Population-averaged risks from exposures following major radiation incidents are clearly significant, but may be no greater than those from other much more common environmental and lifestyle factors. This comparative analysis, whilst highlighting inevitable uncertainties in risk quantification and comparison, helps place the potential consequences of radiation exposures in the context of other public health risks.

  17. Calorie restriction reduces the incidence of radiation-induced myeloid leukemia and spontaneous tumor

    International Nuclear Information System (INIS)

    Yoshida, Kazuko

    1999-01-01

    The host-defense mechanisms against cancers are known to be modulated by changing the environmental factor(s). The spontaneous incidence of myeloid leukemia is about 1% in C3H/He mice, and the incidence increases up to 23.3% when a single dose of radiation, 3 Gy X-ray, is exposed to a whole-body. Since calorie restriction was known to reduce the incidence of spontaneous tumors, a question as to whether such radiation induced-increase of myeloid leukemia would be also decreased by calorie restriction, was aimed to answer to elucidate possible mechanism of radiation-induced myeloid leukemia. By the calorie restriction, the incidence of myeloid leukemia was significantly decreased; it was reduced to 7.9% and 10.7% when restriction was started before (6 weeks old) and after (10 weeks old) irradiation, respectively. In addition, the latent period of the myeloid leukemia in the groups for calorie restriction was significantly extended at a greater extent as compared with the control diet groups. Number of hematopoietic stem cells, the possible target cells for radiation-induced leukemias, in the groups for the calorie restriction demonstrated a significant decrease, especially in the spleen, as compared with that in the control, when the evaluation was made at the time of radiation exposure. Then, we examined whether the decreased number of target cells at the time of exposure is caused by the reduction of radiation-induced myeloid leukemia with caloric restriction. The third restricted groups were fed 65 kcal diet (restricted diet) for the first 4 weeks i.e. from 6 weeks to 10 weeks old, then, the mice were fed with control diet after radiation. The incidence of myeloid leukemia in this group was slightly decreased but did not show statistically significance. Therefore, the caloric restriction seems to be more effective in the promotion stage than the initiation stage on radiation-induced leukemogenesis. It is well known that C3H/He mice develop hepatoma spontaneously

  18. The cryogenic source of slow monochromatic positrons

    International Nuclear Information System (INIS)

    Meshkov, I.N.; Pavlov, V.N.; Sidorin, A.O.; Yakovenko, S.L.

    2008-01-01

    The cryogenic source of slow monochromatic positrons based on the 22 Na isotope has been designed and constructed at JINR. Positrons emitted from radioactive source 22 Na have a very broad energy spectrum up to 0.5 MeV. To generate monochromatic beam of slow positrons the solid neon is used as a moderator. The solid neon allows forming slow positron beam of the energy of 1.2 eV at the spectrum width of 1 eV. The efficiency of moderation is 1 % of total positron flux

  19. An analysis of the incidence and related factors for radiation dermatitis in breast cancer patients who receive radiation therapy

    International Nuclear Information System (INIS)

    Lee, Sun Young; Kwon, Hyoung Cheol; Kim, Jung Soo; Lee, Heui Kwan

    2010-01-01

    We analyzed the incidence and related factors of radiation dermatitis; at first, to recognize whether a decrease in radiation dermatitis is possible or not in breast cancer patients who received radiation therapy. Of 338 patients, 284 with invasive breast cancer who received breast conservation surgery with radiotherapy at Chonbuk National University Hospital from January 2007 to June 2009 were evaluated. Patients who also underwent bolus, previous contralateral breast irradiation and irradiation on both breasts were excluded. For patients who appeared to have greater than moderate radiation dermatitis, the incidence and relating factors for radiation dermatitis were analyzed retrospectively. A total of 207 and 77 patients appeared to have RTOG grade 0/1 or above RTOG grade 2 radiation dermatitis, respectively. The factors found to be statistically significant for the 77 patients who appeared to have greater than moderate radiation dermatitis include the presence of lymphocele due to the stasis of lymph and lymph edema which affect the healing disturbance of radiation dermatitis (p=0.003, p=0.001). Moreover, an allergic reaction to plaster due to the immune cells of skin and the activation of cytokine and concomitant hormonal therapy were also statistically significant factors (p=0.001, p=0.025). Most of the breast cancer patients who received radiation therapy appeared to have a greater than mild case of radiation dermatitis. Lymphocele, lymphedema, an allergy to plaster and concomitant hormonal therapy which affect radiation dermatitis were found to be significant factors. Consequently, we should eliminate lymphocele prior to radiation treatment for patients who appear to have an allergic reaction to plaster. We should also instruct patients of methods to maintain skin moisture if they appear to have a greater than moderate case of radiation dermatitis.

  20. Relationship of cancer incidence to terrestrial radiation and population density in Connecticut, 1935-1974

    International Nuclear Information System (INIS)

    Walter, S.D.; Meigs, J.W.; Heston, J.F.

    1986-01-01

    The relationship of cancer incidence to terrestrial radiation and population density was investigated. Cancer incidence was obtained using 40 years of age-standardized data from the Connecticut Tumor Registry, and environmental radiation was estimated using data from an airborne gamma radiation survey of the entire state. These variables were examined ecologically, using the 169 towns of the state as the analytic units in a weighted regression analysis. The study design involves a large population base in a state having relatively high terrestrial radiation exposure levels overall and reasonable variation in exposure between towns. For all cancer combined, only one of the eight sex-specific analyses by decade yielded a significant radiation regression coefficient, and this was negative. In the sex- and site-specific analyses, almost all the coefficients for radiation were not significantly different from zero. In contrast, significant positive relationships of cancer incidence with population density were found for all cancer, for cancer of the lung for both sexes, for stomach, colonic, and prostatic cancer for males, and for lymphomas, thyroid, breast, and ovarian cancer for females. Both the radiation and population density relationships were adjusted for socioeconomic status. Socioeconomic status was significantly negatively associated with stomach and lung cancer in males and with cervical cancer in females; it was also positively associated with lymphomas and breast cancer in females. A power calculation revealed that, despite the relatively large size of this study, there was only a small probability of detecting a radiation effect of the strength anticipated from previous estimates

  1. Identifying Predictive Factors for Incident Reports in Patients Receiving Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Elnahal, Shereef M., E-mail: selnaha1@jhmi.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Blackford, Amanda [Department of Oncology Biostatistics, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Smith, Koren; Souranis, Annette N.; Briner, Valerie; McNutt, Todd R.; DeWeese, Theodore L.; Wright, Jean L.; Terezakis, Stephanie A. [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, Maryland (United States)

    2016-04-01

    Purpose: To describe radiation therapy cases during which voluntary incident reporting occurred; and identify patient- or treatment-specific factors that place patients at higher risk for incidents. Methods and Materials: We used our institution's incident learning system to build a database of patients with incident reports filed between January 2011 and December 2013. Patient- and treatment-specific data were reviewed for all patients with reported incidents, which were classified by step in the process and root cause. A control group of patients without events was generated for comparison. Summary statistics, likelihood ratios, and mixed-effect logistic regression models were used for group comparisons. Results: The incident and control groups comprised 794 and 499 patients, respectively. Common root causes included documentation errors (26.5%), communication (22.5%), technical treatment planning (37.5%), and technical treatment delivery (13.5%). Incidents were more frequently reported in minors (age <18 years) than in adult patients (37.7% vs 0.4%, P<.001). Patients with head and neck (16% vs 8%, P<.001) and breast (20% vs 15%, P=.03) primaries more frequently had incidents, whereas brain (18% vs 24%, P=.008) primaries were less frequent. Larger tumors (17% vs 10% had T4 lesions, P=.02), and cases on protocol (9% vs 5%, P=.005) or with intensity modulated radiation therapy/image guided intensity modulated radiation therapy (52% vs 43%, P=.001) were more likely to have incidents. Conclusions: We found several treatment- and patient-specific variables associated with incidents. These factors should be considered by treatment teams at the time of peer review to identify patients at higher risk. Larger datasets are required to recommend changes in care process standards, to minimize safety risks.

  2. Identifying Predictive Factors for Incident Reports in Patients Receiving Radiation Therapy

    International Nuclear Information System (INIS)

    Elnahal, Shereef M.; Blackford, Amanda; Smith, Koren; Souranis, Annette N.; Briner, Valerie; McNutt, Todd R.; DeWeese, Theodore L.; Wright, Jean L.; Terezakis, Stephanie A.

    2016-01-01

    Purpose: To describe radiation therapy cases during which voluntary incident reporting occurred; and identify patient- or treatment-specific factors that place patients at higher risk for incidents. Methods and Materials: We used our institution's incident learning system to build a database of patients with incident reports filed between January 2011 and December 2013. Patient- and treatment-specific data were reviewed for all patients with reported incidents, which were classified by step in the process and root cause. A control group of patients without events was generated for comparison. Summary statistics, likelihood ratios, and mixed-effect logistic regression models were used for group comparisons. Results: The incident and control groups comprised 794 and 499 patients, respectively. Common root causes included documentation errors (26.5%), communication (22.5%), technical treatment planning (37.5%), and technical treatment delivery (13.5%). Incidents were more frequently reported in minors (age <18 years) than in adult patients (37.7% vs 0.4%, P<.001). Patients with head and neck (16% vs 8%, P<.001) and breast (20% vs 15%, P=.03) primaries more frequently had incidents, whereas brain (18% vs 24%, P=.008) primaries were less frequent. Larger tumors (17% vs 10% had T4 lesions, P=.02), and cases on protocol (9% vs 5%, P=.005) or with intensity modulated radiation therapy/image guided intensity modulated radiation therapy (52% vs 43%, P=.001) were more likely to have incidents. Conclusions: We found several treatment- and patient-specific variables associated with incidents. These factors should be considered by treatment teams at the time of peer review to identify patients at higher risk. Larger datasets are required to recommend changes in care process standards, to minimize safety risks.

  3. Optimizing Monochromatic Focusing on ThALES

    Czech Academy of Sciences Publication Activity Database

    Čermák, P.; Boehm, M.; Kulda, J.; Roux, S.; Hiess, A.; Steffens, P.; Šaroun, Jan

    2014-01-01

    Roč. 82, A (2014), SA026 ISSN 0031-9015 Institutional support: RVO:61389005 Keywords : Monte Carlo ray-tracing * inelastic neutron scattering * Triple-Axis spectrometer * monochromatic focusing Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.585, year: 2014

  4. Medical treatment of radiation damages and medical emergency planning in case of nuclear power plant incidents and accidents

    International Nuclear Information System (INIS)

    Ohlenschlaeger, L.

    1981-03-01

    Medical measures in case of radiation damages are discussed on the basis of five potential categories of radiation incidents and accidents, respectively, viz. contaminations, incorporations, external local and general radiation over-exposures, contaminated wounds, and combinations of radiation damages and conventional injuries. Considerations are made for diagnostic and therapeutic initial measures especially in case of minor and moderate radiation accidents. The medical emergency planning is reviewed by means of definations used in the practical handling of incidents or accidents. The parameters are: extent of the incident or accident, number of persons involved, severity of radiation damage. Based on guiding symptoms the criteria for the classification into minor, moderate or severe radiation accidents are discussed. Reference is made to the Medical Radiation Protection Centers existing in the Federal Republic of Germany and the possibility of getting advices in case of radiation incidents and accidents. (orig.) [de

  5. Leakage of an irradiator source: The June 1988 Georgia RSI [Radiation Sterilizers, Inc.] incident

    International Nuclear Information System (INIS)

    1990-02-01

    On June 6, 1988, operators of a pool irradiator in Decatur, Georgia, were prevented by a safety system from raising sources from the pool. Radiation levels of 60 millirem per hour at the surface of the pool water were found, indicative of a leak of one or more of the 252 Cs-137 source capsules used at the irradiator. A summary of the Incident Evaluation Task Force's First Interim Report has been prepared for person's needing an overview of the incident and lessons learned to date. This report provides a summary of Agreement States' views and recommendations on some of the issues raised by the incident

  6. Characteristics of a multi-keV monochromatic point x-ray source

    Indian Academy of Sciences (India)

    Temporal, spatial and spectral characteristics of a multi-keV monochromatic point x-ray source based on vacuum diode with laser-produced plasma as cathode are presented. Electrons from a laser-produced aluminium plasma were accelerated towards a conical point tip titanium anode to generate K-shell x-ray radiation.

  7. A mirror for lab-based quasi-monochromatic parallel x-rays.

    Science.gov (United States)

    Nguyen, Thanhhai; Lu, Xun; Lee, Chang Jun; Jung, Jin-Ho; Jin, Gye-Hwan; Kim, Sung Youb; Jeon, Insu

    2014-09-01

    A multilayered parabolic mirror with six W/Al bilayers was designed and fabricated to generate monochromatic parallel x-rays using a lab-based x-ray source. Using this mirror, curved bright bands were obtained in x-ray images as reflected x-rays. The parallelism of the reflected x-rays was investigated using the shape of the bands. The intensity and monochromatic characteristics of the reflected x-rays were evaluated through measurements of the x-ray spectra in the band. High intensity, nearly monochromatic, and parallel x-rays, which can be used for high resolution x-ray microscopes and local radiation therapy systems, were obtained.

  8. Radiation-Induced Breast Cancer Incidence and Mortality From Digital Mammography Screening: A Modeling Study.

    Science.gov (United States)

    Miglioretti, Diana L; Lange, Jane; van den Broek, Jeroen J; Lee, Christoph I; van Ravesteyn, Nicolien T; Ritley, Dominique; Kerlikowske, Karla; Fenton, Joshua J; Melnikow, Joy; de Koning, Harry J; Hubbard, Rebecca A

    2016-02-16

    Estimates of risk for radiation-induced breast cancer from mammography screening have not considered variation in dose exposure or diagnostic work-up after abnormal screening results. To estimate distributions of radiation-induced breast cancer incidence and mortality from digital mammography screening while considering exposure from screening and diagnostic mammography and dose variation among women. 2 simulation-modeling approaches. U.S. population. Women aged 40 to 74 years. Annual or biennial digital mammography screening from age 40, 45, or 50 years until age 74 years. Lifetime breast cancer deaths averted (benefits) and radiation-induced breast cancer incidence and mortality (harms) per 100,000 women screened. Annual screening of 100,000 women aged 40 to 74 years was projected to induce 125 breast cancer cases (95% CI, 88 to 178) leading to 16 deaths (CI, 11 to 23), relative to 968 breast cancer deaths averted by early detection from screening. Women exposed at the 95th percentile were projected to develop 246 cases of radiation-induced breast cancer leading to 32 deaths per 100,000 women. Women with large breasts requiring extra views for complete examination (8% of population) were projected to have greater radiation-induced breast cancer risk (266 cancer cases and 35 deaths per 100,000 women) than other women (113 cancer cases and 15 deaths per 100,000 women). Biennial screening starting at age 50 years reduced risk for radiation-induced cancer 5-fold. Life-years lost from radiation-induced breast cancer could not be estimated. Radiation-induced breast cancer incidence and mortality from digital mammography screening are affected by dose variability from screening, resultant diagnostic work-up, initiation age, and screening frequency. Women with large breasts may have a greater risk for radiation-induced breast cancer. Agency for Healthcare Research and Quality, U.S. Preventive Services Task Force, National Cancer Institute.

  9. Adverse radiation effect after stereotactic radiosurgery for brain metastases : incidence, time course, and risk factors

    NARCIS (Netherlands)

    Sneed, Penny K.; Mendez, Joe; Vemer-van den Hoek, Johanna; Seymour, Zachary A.; Ma, Lijun; Molinaro, Annette M.; Fogh, Shannon E.; Nakamura, Jean L.; McDermott, Michael W.

    OBJECT The authors sought to determine the incidence, time course, and risk factors for overall adverse radiation effect (ARE) and symptomatic ARE after stereotactic radiosurgery (SRS) for brain metastases. METHODS All cases of brain metastases treated from 1998 through 2009 with Gamma Knife SRS at

  10. Emergency reception of accidents and incidents in working with ionizing radiation

    International Nuclear Information System (INIS)

    Abrahamse, J.C.; Gispen, J.G.W.

    1989-01-01

    This manual is intended to be a general manual for the responsible expert regarding radiation hygienics in order to assist him in establishing an organization for combat of accidents and incidents. First attention is paid considerations underlying emergency measures and aid, subsequently the demands and desirabilities in the practical organization are discussed. (author). 3 figs

  11. SU-E-T-524: Web-Based Radiation Oncology Incident Reporting and Learning System (ROIRLS)

    International Nuclear Information System (INIS)

    Kapoor, R; Palta, J; Hagan, M; Grover, S; Malik, G

    2014-01-01

    Purpose: Describe a Web-based Radiation Oncology Incident Reporting and Learning system that has the potential to improve quality of care for radiation therapy patients. This system is an important facet of continuing effort by our community to maintain and improve safety of radiotherapy.Material and Methods: The VA National Radiation Oncology Program office has embarked on a program to electronically collect adverse events and near miss data of radiation treatment of over 25,000 veterans treated with radiotherapy annually. Software used for this program is deployed on the VAs intranet as a Website. All data entry forms (adverse event or near miss reports, work product reports) utilize standard causal, RT process step taxonomies and data dictionaries defined in AAPM and ASTRO reports on error reporting (AAPM Work Group Report on Prevention of Errors and ASTROs safety is no accident report). All reported incidents are investigated by the radiation oncology domain experts. This system encompasses the entire feedback loop of reporting an incident, analyzing it for salient details, and developing interventions to prevent it from happening again. The operational workflow is similar to that of the Aviation Safety Reporting System. This system is also synergistic with ROSIS and SAFRON. Results: The ROIRLS facilitates the collection of data that help in tracking adverse events and near misses and develop new interventions to prevent such incidents. The ROIRLS electronic infrastructure is fully integrated with each registered facility profile data thus minimizing key strokes and multiple entries by the event reporters. Conclusions: OIRLS is expected to improve the quality and safety of a broad spectrum of radiation therapy patients treated in the VA and fulfills our goal of Effecting Quality While Treating Safely The Radiation Oncology Incident Reporting and Learning System software used for this program has been developed, conceptualized and maintained by TSG Innovations

  12. SU-E-T-524: Web-Based Radiation Oncology Incident Reporting and Learning System (ROIRLS)

    Energy Technology Data Exchange (ETDEWEB)

    Kapoor, R; Palta, J; Hagan, M [Virginia Commonwealth University, Richmond, VA (United States); National Radiation Oncology Program (10P4H), Richmond, VA (United States); Grover, S; Malik, G [TSG Innovations Inc., Richmond, VA (United States)

    2014-06-01

    Purpose: Describe a Web-based Radiation Oncology Incident Reporting and Learning system that has the potential to improve quality of care for radiation therapy patients. This system is an important facet of continuing effort by our community to maintain and improve safety of radiotherapy.Material and Methods: The VA National Radiation Oncology Program office has embarked on a program to electronically collect adverse events and near miss data of radiation treatment of over 25,000 veterans treated with radiotherapy annually. Software used for this program is deployed on the VAs intranet as a Website. All data entry forms (adverse event or near miss reports, work product reports) utilize standard causal, RT process step taxonomies and data dictionaries defined in AAPM and ASTRO reports on error reporting (AAPM Work Group Report on Prevention of Errors and ASTROs safety is no accident report). All reported incidents are investigated by the radiation oncology domain experts. This system encompasses the entire feedback loop of reporting an incident, analyzing it for salient details, and developing interventions to prevent it from happening again. The operational workflow is similar to that of the Aviation Safety Reporting System. This system is also synergistic with ROSIS and SAFRON. Results: The ROIRLS facilitates the collection of data that help in tracking adverse events and near misses and develop new interventions to prevent such incidents. The ROIRLS electronic infrastructure is fully integrated with each registered facility profile data thus minimizing key strokes and multiple entries by the event reporters. Conclusions: OIRLS is expected to improve the quality and safety of a broad spectrum of radiation therapy patients treated in the VA and fulfills our goal of Effecting Quality While Treating Safely The Radiation Oncology Incident Reporting and Learning System software used for this program has been developed, conceptualized and maintained by TSG Innovations

  13. The Response of the Ocean Thermal Skin Layer to Variations in Incident Infrared Radiation

    Science.gov (United States)

    Wong, Elizabeth W.; Minnett, Peter J.

    2018-04-01

    Ocean warming trends are observed and coincide with the increase in concentrations of greenhouse gases in the atmosphere resulting from human activities. At the ocean surface, most of the incoming infrared (IR) radiation is absorbed within the top micrometers of the ocean's surface where the thermal skin layer (TSL) exists. Thus, the incident IR radiation does not directly heat the upper few meters of the ocean. This paper investigates the physical mechanism between the absorption of IR radiation and its effect on heat transfer at the air-sea boundary. The hypothesis is that given the heat lost through the air-sea interface is controlled by the TSL, the TSL adjusts in response to variations in incident IR radiation to maintain the surface heat loss. This modulates the flow of heat from below and hence controls upper ocean heat content. This hypothesis is tested using the increase in incoming longwave radiation from clouds and analyzing vertical temperature profiles in the TSL retrieved from sea-surface emission spectra. The additional energy from the absorption of increasing IR radiation adjusts the curvature of the TSL such that the upward conduction of heat from the bulk of the ocean into the TSL is reduced. The additional energy absorbed within the TSL supports more of the surface heat loss. Thus, more heat beneath the TSL is retained leading to the observed increase in upper ocean heat content.

  14. Female all cancer incidence in medical radiation workers in Latvia 1982-2002

    International Nuclear Information System (INIS)

    Matisane, L.; Carpenter, L.; Venables, K.

    2005-01-01

    Medical radiation workers belong to one of the oldest occupational groups exposed to external radiation. Since the various radiological protection recommendations have been introduced, now ths process has resulted in low-dose exposure, regular monitoring of exposure and establishment of national dose registration bodies. In order to provide additional information to studies on cancer incidence among medical radiation workers (specially female workers) and in order to assess all cancer incidence in female medical radiation workers in Latvia, a retrospective cohort study based on the National Dose Register was set up in Latvia. The study cohort consisted of all workers employed in health care, occupationally exposed to ionising radiation for more than one year in any of the public health care establishments in Latvia, except military ones, between 1 January 1972 and 1 January 2002 and who were registered in the National Dose Register of Latvia. The cohort consisted of 1416 female medical radiation workers either in hospitals or outpatient departments, or both. The cohort included diagnostic and therapeutic radiologists with predominantly medical qualification, it also included radiotechnologits, nurses, junior nurses, but it did not include academic, physicists and dentists. In all cases the calculated SIR was over than expected or close to expected. Several major differences in study design makes ir difficult to compare the results of this study with the results of the studies carried out in other countries

  15. Estimating photosynthetic radiation use efficiency using incident light and photosynthesis of individual leaves.

    Science.gov (United States)

    Rosati, A; Dejong, T M

    2003-06-01

    It has been theorized that photosynthetic radiation use efficiency (PhRUE) over the course of a day is constant for leaves throughout a canopy if leaf nitrogen content and photosynthetic properties are adapted to local light so that canopy photosynthesis over a day is optimized. To test this hypothesis, 'daily' photosynthesis of individual leaves of Solanum melongena plants was calculated from instantaneous rates of photosynthesis integrated over the daylight hours. Instantaneous photosynthesis was estimated from the photosynthetic responses to photosynthetically active radiation (PAR) and from the incident PAR measured on individual leaves during clear and overcast days. Plants were grown with either abundant or scarce N fertilization. Both net and gross daily photosynthesis of leaves were linearly related to daily incident PAR exposure of individual leaves, which implies constant PhRUE over a day throughout the canopy. The slope of these relationships (i.e. PhRUE) increased with N fertilization. When the relationship was calculated for hourly instead of daily periods, the regressions were curvilinear, implying that PhRUE changed with time of the day and incident radiation. Thus, linearity (i.e. constant PhRUE) was achieved only when data were integrated over the entire day. Using average PAR in place of instantaneous incident PAR increased the slope of the relationship between daily photosynthesis and incident PAR of individual leaves, and the regression became curvilinear. The slope of the relationship between daily gross photosynthesis and incident PAR of individual leaves increased for an overcast compared with a clear day, but the slope remained constant for net photosynthesis. This suggests that net PhRUE of all leaves (and thus of the whole canopy) may be constant when integrated over a day, not only when the incident PAR changes with depth in the canopy, but also when it varies on the same leaf owing to changes in daily incident PAR above the canopy. The

  16. Incidence of Second Malignancies Among Patients Treated With Proton Versus Photon Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Christine S., E-mail: chungc1@sutterhealth.org [Department of Radiation Oncology, Alta Bates Summit Medical Center, Berkeley, California (United States); Yock, Torunn I. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Nelson, Kerrie [Department of Biostatistics, Boston University School of Public Health, Boston, Massachusetts (United States); Xu, Yang [Department of Health Care Policy, Harvard Medical School, Boston, Massachusetts (United States); Keating, Nancy L. [Department of Health Care Policy, Harvard Medical School, Boston, Massachusetts (United States); Department of General Internal Medicine, Brigham and Women' s Hospital, Boston, Massachusetts (United States); Tarbell, Nancy J. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Office of the Executive Dean, Harvard Medical School, Boston, Massachusetts (United States)

    2013-09-01

    Purpose: Proton radiation, when compared with photon radiation, allows delivery of increased radiation dose to the tumor while decreasing dose to adjacent critical structures. Given the recent expansion of proton facilities in the United States, the long-term sequelae of proton therapy should be carefully assessed. The objective of this study was to compare the incidence of second cancers in patients treated with proton radiation with a population-based cohort of matched patients treated with photon radiation. Methods and Materials: We performed a retrospective cohort study of 558 patients treated with proton radiation from 1973 to 2001 at the Harvard Cyclotron in Cambridge, MA and 558 matched patients treated with photon therapy in the Surveillance, Epidemiology, and End Results (SEER) Program cancer registry. Patients were matched by age at radiation treatment, sex, year of treatment, cancer histology, and site. The main outcome measure was the incidence of second malignancies after radiation. Results: We matched 558 proton patients with 558 photon patients from the Surveillance, Epidemiology, and End Results registry. The median duration of follow-up was 6.7 years (interquartile range, 7.4) and 6.0 years (interquartile range, 9.3) in the proton and photon cohorts, respectively. The median age at treatment was 59 years in each cohort. Second malignancies occurred in 29 proton patients (5.2%) and 42 photon patients (7.5%). After we adjusted for sex, age at treatment, primary site, and year of diagnosis, proton therapy was not associated with an increased risk of second malignancy (adjusted hazard ratio, 0.52 [95% confidence interval, 0.32-0.85]; P=.009). Conclusions: The use of proton radiation therapy was not associated with a significantly increased risk of secondary malignancies compared with photon therapy. Longer follow-up of these patients is needed to determine if there is a significant decrease in second malignancies. Given the limitations of the study

  17. Incidence of Second Malignancies Among Patients Treated With Proton Versus Photon Radiation

    International Nuclear Information System (INIS)

    Chung, Christine S.; Yock, Torunn I.; Nelson, Kerrie; Xu, Yang; Keating, Nancy L.; Tarbell, Nancy J.

    2013-01-01

    Purpose: Proton radiation, when compared with photon radiation, allows delivery of increased radiation dose to the tumor while decreasing dose to adjacent critical structures. Given the recent expansion of proton facilities in the United States, the long-term sequelae of proton therapy should be carefully assessed. The objective of this study was to compare the incidence of second cancers in patients treated with proton radiation with a population-based cohort of matched patients treated with photon radiation. Methods and Materials: We performed a retrospective cohort study of 558 patients treated with proton radiation from 1973 to 2001 at the Harvard Cyclotron in Cambridge, MA and 558 matched patients treated with photon therapy in the Surveillance, Epidemiology, and End Results (SEER) Program cancer registry. Patients were matched by age at radiation treatment, sex, year of treatment, cancer histology, and site. The main outcome measure was the incidence of second malignancies after radiation. Results: We matched 558 proton patients with 558 photon patients from the Surveillance, Epidemiology, and End Results registry. The median duration of follow-up was 6.7 years (interquartile range, 7.4) and 6.0 years (interquartile range, 9.3) in the proton and photon cohorts, respectively. The median age at treatment was 59 years in each cohort. Second malignancies occurred in 29 proton patients (5.2%) and 42 photon patients (7.5%). After we adjusted for sex, age at treatment, primary site, and year of diagnosis, proton therapy was not associated with an increased risk of second malignancy (adjusted hazard ratio, 0.52 [95% confidence interval, 0.32-0.85]; P=.009). Conclusions: The use of proton radiation therapy was not associated with a significantly increased risk of secondary malignancies compared with photon therapy. Longer follow-up of these patients is needed to determine if there is a significant decrease in second malignancies. Given the limitations of the study

  18. Validating FMEA output against incident learning data: A study in stereotactic body radiation therapy.

    Science.gov (United States)

    Yang, F; Cao, N; Young, L; Howard, J; Logan, W; Arbuckle, T; Sponseller, P; Korssjoen, T; Meyer, J; Ford, E

    2015-06-01

    Though failure mode and effects analysis (FMEA) is becoming more widely adopted for risk assessment in radiation therapy, to our knowledge, its output has never been validated against data on errors that actually occur. The objective of this study was to perform FMEA of a stereotactic body radiation therapy (SBRT) treatment planning process and validate the results against data recorded within an incident learning system. FMEA on the SBRT treatment planning process was carried out by a multidisciplinary group including radiation oncologists, medical physicists, dosimetrists, and IT technologists. Potential failure modes were identified through a systematic review of the process map. Failure modes were rated for severity, occurrence, and detectability on a scale of one to ten and risk priority number (RPN) was computed. Failure modes were then compared with historical reports identified as relevant to SBRT planning within a departmental incident learning system that has been active for two and a half years. Differences between FMEA anticipated failure modes and existing incidents were identified. FMEA identified 63 failure modes. RPN values for the top 25% of failure modes ranged from 60 to 336. Analysis of the incident learning database identified 33 reported near-miss events related to SBRT planning. Combining both methods yielded a total of 76 possible process failures, of which 13 (17%) were missed by FMEA while 43 (57%) identified by FMEA only. When scored for RPN, the 13 events missed by FMEA ranked within the lower half of all failure modes and exhibited significantly lower severity relative to those identified by FMEA (p = 0.02). FMEA, though valuable, is subject to certain limitations. In this study, FMEA failed to identify 17% of actual failure modes, though these were of lower risk. Similarly, an incident learning system alone fails to identify a large number of potentially high-severity process errors. Using FMEA in combination with incident learning may

  19. Immune responsiveness and incidence of reticulum cell sarcoma in long-term syngeneic radiation chimeras

    International Nuclear Information System (INIS)

    Adorini, L.; Gorini, G.; Covelli, V.; Ballardin, E.; di Michele, A.; Bassani, B.; Metalli, P.; Doria, G.

    1976-01-01

    Long-term syngeneic radiation chimeras displayed a very low incidence of reticulum cell sarcoma as compared with control mice. Immune reactivity of these animals was studied in vivo by anti-dinitrophenyl antibody titer and affinity and in vitro by mitotic responsiveness to phytohemagglutinin, concanavalin A and lipopolysaccharide. Antibody titer and affinity as well as the response to T lectins were found to be increased in chimeras. These results were attributed to increased function of mature T2 cells, which could explain the reduced incidence of reticulum cell sarcoma in chimeras

  20. Three-dimensional monochromatic x-ray CT

    Science.gov (United States)

    Saito, Tsuneo; Kudo, Hiroyuki; Takeda, Tohoru; Itai, Yuji; Tokumori, Kenji; Toyofuku, Fukai; Hyodo, Kazuyuki; Ando, Masami; Nishimura, Ktsuyuki; Uyama, Chikao

    1995-08-01

    In this paper, we describe a 3D computed tomography (3D CT) using monochromatic x-rays generated by synchrotron radiation, which performs a direct reconstruction of 3D volume image of an object from its cone-beam projections. For the develpment of 3D CT, scanning orbit of x-ray source to obtain complete 3D information about an object and corresponding 3D image reconstruction algorithm are considered. Computer simulation studies demonstrate the validities of proposed scanning method and reconstruction algorithm. A prototype experimental system of 3D CT was constructed. Basic phantom examinations and specific material CT image by energy subtraction obtained in this experimental system are shown.

  1. Radiation protection measures in the case of incidents and radiation accidents

    International Nuclear Information System (INIS)

    Herzberg, B.

    1976-01-01

    Measures to be taken in the case of radiation accidents connected with an unusually high radiation exposure to persons, the amounts of which exceed the limiting values, with depend on whether there has been an external or an internal exposure. In order to give further treatment in the case of whole-body or partial-body irradiation, it is necessary to estimate the exposure dose. In nuclear medicine the accident doses are generally low, i.e. acute radiation damage does not occur here, and immediate measures are not necessary. Therapeutic measures in the case of incorporation accidents are only necessary when the maximum amounts for the nuclide in question recommended by the ICRP has been reached or exceeded in the organism. However, decorporation measures ought to be carried out only by qualified radiation protection physicians. The type of radiation accident which occurs most frequently in nuclear medicine is radiation exposure as a result of contamination. If in the case of contamination of a person the measurement exceeds the radioactivity limit, the decontamination measures are necessary. In the present contribution, these measures for cases without injuries are described in detail. (orig./HP) [de

  2. Radiating low back pain in general practice : Incidence, prevalence, diagnosis, and long-term clinical course of illness

    NARCIS (Netherlands)

    Spijker-Huiges, Antje; Groenhof, Feikje; Winters, Jan C.; van Wijhe, Marten; Groenier, Klaas H.; van der Meer, Klaas

    Objective. The aim of this study was to calculate the incidence and prevalence of radiating low back pain, to explore the long-term clinical course of radiating low back pain including the influence of radiculopathy (in a subsample of the study population) and non-radiating low back pain thereon,

  3. Radiation risk factors in incidence anortality among exposed individuals of East Kazakhstand m

    Directory of Open Access Journals (Sweden)

    Kazbek Apsalikov

    2014-01-01

    Full Text Available Introduction: Lengthy clinical and epidemiological studies at the Research Institute of Radiation Medicine and Ecology have discovered basic patterns of long-term effects from ionizing radiation in population groups exposed to radiation risk. Methodology for calculating injury from radiation risk factors has been developed and implemented to minimize the effects of the Semipalatinsk nuclear test site (SNTS. Material and methods: We analyzed materials from the database of the Scientific Medical Register that were exposed to radiation as a result of SNTS. We analyzed both male and female populations of the Abay, Beskaragai and Zhanasemei, Kokpekti (control areas of East-Kazakhstan region (EKR from 2008-2012. These populations were split into three groups allocated by the generation. The first group represented persons born from the period of 01/01/1930 -08/01/1949 and their children born from the period of 10/09/1949-12/31/1962. The second group were persons born after 01/01/1963. The third group served as the control and were persons who immigrated to these areas after 1990. Results: There was an increased incidence of cancer (21.5%, p < 0.000734, cardiovascular diseases (10.2%; respiratory problems (9.6%, gastrointestinal issues (9.1%, p < 0.00371-0.00679 in the first group. The effect of the radiation dose has not been fully stuided among the subjects in the second group.The major causes of excess mortality in the first group were neoplams (30.6%, hypertension (23.8%, and myocardial infarction (22.6%. The effects of radiation influenced mortality in the second group were 2-2.5 times lower than the first group.Conclusion: There is a correlation between the size of the radiation dose, the risk profile, and age at the moment of radiation exposure with trends of morbidity and mortality in the radiation exposed areas.

  4. Improved sensitivity in patients with peripheral neuropathy: effects of monochromatic infrared photo energy.

    Science.gov (United States)

    DeLellis, Salvatore L; Carnegie, Dale H; Burke, Thomas J

    2005-01-01

    The medical records of 1,047 patients (mean age, 73 years) with established peripheral neuropathy were examined to determine whether treatment with monochromatic infrared photo energy was associated with increased foot sensitivity to the 5.07 Semmes-Weinstein monofilament. The peripheral neuropathy in 790 of these patients (75%) was due to diabetes mellitus. Before treatment with monochromatic infrared photo energy, of the ten tested sites (five on each foot), a mean +/- SD of 7.9 +/- 2.4 sites were insensitive to the 5.07 Semmes-Weinstein monofilament, and 1,033 patients exhibited loss of protective sensation. After treatment, the mean +/- SD number of insensate sites on both feet was 2.3 +/- 2.4, an improvement of 71%. Only 453 of 1,033 patients (43.9%) continued to have loss of protective sensation after treatment. Therefore, monochromatic infrared photo energy treatment seems to be associated with significant clinical improvement in foot sensation in patients, primarily Medicare aged, with peripheral neuropathy. Because insensitivity to the 5.07 Semmes-Weinstein monofilament has been reported to be a major risk factor for diabetic foot wounds, the use of monochromatic infrared photo energy may be associated with a reduced incidence of diabetic foot wounds and amputations.

  5. Has the incidence of radiation-induced bowel damage following treatment of uterine carcinoma changed in the last 20 years

    International Nuclear Information System (INIS)

    Allen-Mersh, T.C.; Wilson, E.J.; Hope-Stone, H.F.; Mann, C.V.

    1986-01-01

    Radiation-induced bowel damage occurred in 4.3% of patients treated primarily by irradiation for uterine carcinoma during the period 1962-1982. There has been a progressive rise in the incidence of radiation damage and radiation-induced rectovaginal fistula during this 20-year period. Radiation from intracavitary sources was a contributory factor in 92% of injured cases. The rising incidence of bowel damage in our patients may be due to an increase in the number of patients receiving a high rectal dose from the intracavitary source. There was a significantly (P<0.01) higher incidence of radiation injury in cases of cervical carcinoma compared to endometrical carcinoma. This was because cervical carcinoma tended to present at a more advanced stage than endometrial carcinoma and was more frequently treated with combined external and intracavitary irradiation. There was no significant increase in the incidence of complications among patients undergoing hysterectomy. (author)

  6. A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination

    International Nuclear Information System (INIS)

    Jeung, Seung Woon; Lim, Cheong Hwan; Jung, Hong Ryang; Joo, Yeong Cheol; Park, Mi Ja; Han, Beon Hee

    2012-01-01

    cervical vertebra, OID, axis angle, and FID, all of them were shown to have correlations with the incidence angle (p<.01). Conclusively, it was shown that the incidence angle was measured differently from average length of cervical vertebra, OID, FID, and axis slope, as well as from age and sex. Therefore, it can be suggested that the anteroposterior radiation test for cervical vertebra should be conducted by different incidence angles based on age and sex. The data of this study may be used as reference in determining the incidence angle of cervical vertebra tests for the future.

  7. A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination

    Energy Technology Data Exchange (ETDEWEB)

    Jeung, Seung Woon; Lim, Cheong Hwan; Jung, Hong Ryang; Joo, Yeong Cheol; Park, Mi Ja [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of); Han, Beon Hee [Dept. of Radiological Science, Seonam University, Namwon (Korea, Republic of)

    2012-06-15

    of cervical vertebra, OID, axis angle, and FID, all of them were shown to have correlations with the incidence angle (p<.01). Conclusively, it was shown that the incidence angle was measured differently from average length of cervical vertebra, OID, FID, and axis slope, as well as from age and sex. Therefore, it can be suggested that the anteroposterior radiation test for cervical vertebra should be conducted by different incidence angles based on age and sex. The data of this study may be used as reference in determining the incidence angle of cervical vertebra tests for the future.

  8. Medical and policy considerations for nuclear and radiation accidents, incidents and terrorism.

    Science.gov (United States)

    Gale, Robert Peter

    2017-11-01

    The purpose of this review is to address the increasing medical and public concern regarding the health consequences of radiation exposure, a concern shaped not only by fear of another Chernobyl or Fukushima nuclear power facility accident but also by the intentional use of a nuclear weapon, a radiological dispersion device, a radiological exposure device, or an improved nuclear device by rogue states such as North Korea and terrorist organizations such as Al Qaeda and ISIS. The United States has the medical capacity to respond to a limited nuclear or radiation accident or incident but an effective medical response to a catastrophic nuclear event is impossible. Dealing effectively with nuclear and radiation accidents or incidents requires diverse strategies, including policy decisions, public education, and medical preparedness. I review medical consequences of exposures to ionizing radiations, likely concomitant injuries and potential medical intervention. These data should help haematologists and other healthcare professionals understand the principles of medical consequences of nuclear terrorism. However, the best strategy is prevention.

  9. An Evaluation of Departmental Radiation Oncology Incident Reports: Anticipating a National Reporting System

    International Nuclear Information System (INIS)

    Terezakis, Stephanie A.; Harris, Kendra M.; Ford, Eric; Michalski, Jeff; DeWeese, Theodore; Santanam, Lakshmi; Mutic, Sasa; Gay, Hiram

    2013-01-01

    Purpose: Systems to ensure patient safety are of critical importance. The electronic incident reporting systems (IRS) of 2 large academic radiation oncology departments were evaluated for events that may be suitable for submission to a national reporting system (NRS). Methods and Materials: All events recorded in the combined IRS were evaluated from 2007 through 2010. Incidents were graded for potential severity using the validated French Nuclear Safety Authority (ASN) 5-point scale. These incidents were categorized into 7 groups: (1) human error, (2) software error, (3) hardware error, (4) error in communication between 2 humans, (5) error at the human-software interface, (6) error at the software-hardware interface, and (7) error at the human-hardware interface. Results: Between the 2 systems, 4407 incidents were reported. Of these events, 1507 (34%) were considered to have the potential for clinical consequences. Of these 1507 events, 149 (10%) were rated as having a potential severity of ≥2. Of these 149 events, the committee determined that 79 (53%) of these events would be submittable to a NRS of which the majority was related to human error or to the human-software interface. Conclusions: A significant number of incidents were identified in this analysis. The majority of events in this study were related to human error and to the human-software interface, further supporting the need for a NRS to facilitate field-wide learning and system improvement

  10. An Evaluation of Departmental Radiation Oncology Incident Reports: Anticipating a National Reporting System

    Energy Technology Data Exchange (ETDEWEB)

    Terezakis, Stephanie A., E-mail: stereza1@jhmi.edu [Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Harris, Kendra M. [Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Ford, Eric [Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Michalski, Jeff [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri (United States); DeWeese, Theodore [Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Santanam, Lakshmi; Mutic, Sasa; Gay, Hiram [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri (United States)

    2013-03-15

    Purpose: Systems to ensure patient safety are of critical importance. The electronic incident reporting systems (IRS) of 2 large academic radiation oncology departments were evaluated for events that may be suitable for submission to a national reporting system (NRS). Methods and Materials: All events recorded in the combined IRS were evaluated from 2007 through 2010. Incidents were graded for potential severity using the validated French Nuclear Safety Authority (ASN) 5-point scale. These incidents were categorized into 7 groups: (1) human error, (2) software error, (3) hardware error, (4) error in communication between 2 humans, (5) error at the human-software interface, (6) error at the software-hardware interface, and (7) error at the human-hardware interface. Results: Between the 2 systems, 4407 incidents were reported. Of these events, 1507 (34%) were considered to have the potential for clinical consequences. Of these 1507 events, 149 (10%) were rated as having a potential severity of ≥2. Of these 149 events, the committee determined that 79 (53%) of these events would be submittable to a NRS of which the majority was related to human error or to the human-software interface. Conclusions: A significant number of incidents were identified in this analysis. The majority of events in this study were related to human error and to the human-software interface, further supporting the need for a NRS to facilitate field-wide learning and system improvement.

  11. Application of an incident taxonomy for radiation therapy: Analysis of five years of data from three integrated cancer centres.

    Science.gov (United States)

    Greenham, Stuart; Manley, Stephen; Turnbull, Kirsty; Hoffmann, Matthew; Fonseca, Amara; Westhuyzen, Justin; Last, Andrew; Aherne, Noel J; Shakespeare, Thomas P

    2018-01-01

    To develop and apply a clinical incident taxonomy for radiation therapy. Capturing clinical incident information that focuses on near-miss events is critical for achieving higher levels of safety and reliability. A clinical incident taxonomy for radiation therapy was established; coding categories were prescription, consent, simulation, voluming, dosimetry, treatment, bolus, shielding, imaging, quality assurance and coordination of care. The taxonomy was applied to all clinical incidents occurring at three integrated cancer centres for the years 2011-2015. Incidents were managed locally, audited and feedback disseminated to all centres. Across the five years the total incident rate (per 100 courses) was 8.54; the radiotherapy-specific coded rate was 6.71. The rate of true adverse events (unintended treatment and potential patient harm) was 1.06. Adverse events, where no harm was identified, occurred at a rate of 2.76 per 100 courses. Despite workload increases, overall and actual rates both exhibited downward trends over the 5-year period. The taxonomy captured previously unidentified quality assurance failures; centre-specific issues that contributed to variations in incident trends were also identified. The application of a taxonomy developed for radiation therapy enhances incident investigation and facilitates strategic interventions. The practice appears to be effective in our institution and contributes to the safety culture. The ratio of near miss to actual incidents could serve as a possible measure of incident reporting culture and could be incorporated into large scale incident reporting systems.

  12. Analysis of monochromatic signals by using data from the detector of Allegro gravitational waves

    International Nuclear Information System (INIS)

    Oliveira, Fernanda Gomes de

    2010-01-01

    The present work is developed in the searching for monochromatic gravitational waves signals in ALLEGRO's data. We have two procedures for data analysis based on the periodogram of Welch, which a method for the detection of monochromatic signals in the middle of noise which basically makes power spectrum estimates using averaged modified periodograms. By using this method it was possible to obtain a power spectrum for the data which reinforce peaks due to monochromatic signals. The two procedures of analysis for the years 1997 and 1999, were focused on monitoring a peak that appears in the spectral density of ALLEGRO's detector, so called 'mystery mode' (near 887 Hz). We look for variations in the frequency of the mystery mode that agree with the variation of the Doppler effect. In the rst analysis we have used by the variation of daily and annual Doppler shift. For the second one, we have only searched annual Doppler shift. We have applied the periodogram of Welch in both tests in the raw data of the detector in the search for a real signal and we found some peaks that can be candidates of gravitational radiation only the second analysis. In order to test the method we used in both analysis a simulated gravitational wave signal modulated by the Doppler effect injected in the data. We detected in both methods the artificial signal of GW simulated. Therefore we have reason to conclude that both methods are efficient in the search for monochromatic signals. (author)

  13. Effect of incident beam and diffuse radiation on par absorption, photosynthesis and transpiration of sitka spruce - a simulation study

    International Nuclear Information System (INIS)

    Wang, Y.P.; Jarvis, P.G.

    1990-01-01

    A simulation model, Maestro, is used to study the influence of beam fraction in the incident radiation and the radiance distribution of the sky diffuse radiation on PAR absorption, photosynthesis and transpiration of a Sitka spruce (Picea sitchensis (Bong.) Carr) tree crown. It is concluded that inaccurate separation of beam and diffuse radiation leads to significant errors in estimating the amounts of PAR absorbed, photosynthesis and transpiration by a tree in the stand. Much more attention should be paid to adequate descriptions of the radiance distribution of the sky diffuse radiation under different sky conditions. A useful approach is proposed for simulating the incident global radiaiton in a physiological, process-based model

  14. Review of reconstruction of radiation incident air kerma by measurement of absorbed dose in tooth enamel with EPR.

    Science.gov (United States)

    Wieser, A

    2012-03-01

    Electron paramagnetic resonance dosimetry with tooth enamel has been proved to be a reliable method to determine retrospectively exposures from photon fields with minimal detectable doses of 100 mGy or lower, which is lower than achievable with cytogenetic dose reconstruction methods. For risk assessment or validating dosimetry systems for specific radiation incidents, the relevant dose from the incident has to be calculated from the total absorbed dose in enamel by subtracting additional dose contributions from the radionuclide content in teeth, natural external background radiation and medical exposures. For calculating organ doses or evaluating dosimetry systems the absorbed dose in enamel from a radiation incident has to be converted to air kerma using dose conversion factors depending on the photon energy spectrum and geometry of the exposure scenario. This paper outlines the approach to assess individual dose contributions to absorbed dose in enamel and calculate individual air kerma of a radiation incident from the absorbed dose in tooth enamel.

  15. Review of reconstruction of radiation incident air kerma by measurement of absorbed dose in tooth enamel with EPR

    International Nuclear Information System (INIS)

    Wieser, A.

    2012-01-01

    Electron paramagnetic resonance dosimetry with tooth enamel has been proved to be a reliable method to determine retrospectively exposures from photon fields with minimal detectable doses of 100 mGy or lower, which is lower than achievable with cytogenetic dose reconstruction methods. For risk assessment or validating dosimetry systems for specific radiation incidents, the relevant dose from the incident has to be calculated from the total absorbed dose in enamel by subtracting additional dose contributions from the radionuclide content in teeth, natural external background radiation and medical exposures. For calculating organ doses or evaluating dosimetry systems the absorbed dose in enamel from a radiation incident has to be converted to air kerma using dose conversion factors depending on the photon energy spectrum and geometry of the exposure scenario. This paper outlines the approach to assess individual dose contributions to absorbed dose in enamel and calculate individual air kerma of a radiation incident from the absorbed dose in tooth enamel. (author)

  16. Incidence and predictors of Lhermitte’s sign among patients receiving mediastinal radiation for lymphoma

    International Nuclear Information System (INIS)

    Youssef, Bassem; Shank, JoAnn; Reddy, Jay P.; Pinnix, Chelsea C.; Farha, George; Akhtari, Mani; Allen, Pamela K.; Fanale, Michelle A.; Garcia, John A.; Horace, Patricia H.; Milgrom, Sarah; Smith, Grace Li; Nieto, Yago; Arzu, Isadora; Wang, He; Fowler, Nathan; Rodriguez, Maria Alma; Dabaja, Bouthaina

    2015-01-01

    To prospectively examine the risk of developing Lhermitte’s sign (LS) in patients with lymphoma treated with modern-era chemotherapy followed by consolidation intensity-modulated radiation therapy. We prospectively interviewed all patients with lymphoma who received irradiation to the mediastinum from July 2011 through April 2014. We extracted patient, disease, and treatment-related variables from the medical records of those patients and dosimetric variables from treatment-planning systems and analyzed these factors to identify potential predictors of LS with Pearson chi-square tests. During the study period 106 patients received mediastinal radiation for lymphoma, and 31 (29 %) developed LS. No correlations were found between LS and any of the variables examined, including total radiation dose, maximum point dose to the spinal cord, volume receiving 105 % of the dose, and volumes receiving 5 or 15 Gy. In this group of patients, treatment with chemotherapy followed by intensity-modulated radiation therapy led to 29 % developing LS; this symptom was independent of radiation dose and seemed to be an idiosyncratic reaction. This relatively high incidence could have resulted from prospective use of a structured interview

  17. Incidence of neural tube defects in the natural radiation coastal areas of Kerala

    International Nuclear Information System (INIS)

    Jaikrishan, G.; Sudheer, K.R.; Andrews, V.J.; Koya, P.K.M.; Cheriyan, V.D.; Seshadri, M.

    2010-01-01

    All consecutive births in selected government hospitals in and around the high level natural background radiation areas (HLNRA) of Kerala were monitored for congenital malformations observable at birth since 1995. The HLNR area, a coastal strip of land about 55 km in length and 0.5 km in breadth from Purakkad in the north in Alleppey district to Sakthikulangara in the south of Quilon district, stands out among the most prominent background radiation areas of the world. Natural deposit of monazite sand, containing Thorium (8-10%), Uranium (0.3%) and corresponding decay products, is the source of elevated background radiation, ranging from < 1 to 45 mGy/year. Wide variation in dose, due to the patchy and non-uniform distribution of Monazite sand, enables in built controls. High population density, limited migration, ethnic diversity, good literacy, health awareness, institutionalized births and acceptance of small family norm are some of the key features of the population. Areas with a mean radiation dose of more than 1.5 mGy/year were treated as HLNR areas and areas with a dose level of 1.5 mGy/year or less were treated as normal level radiation (NLNR) areas. The study carried out since 1995 does not seem to implicate HLNR in the incidence of neural tube defects among newborns

  18. Incident solar radiation and coronary heart disease mortality rates in Europe

    International Nuclear Information System (INIS)

    Wong, Alfred

    2008-01-01

    The reported low mortality rate from coronary heart disease in Portugal, Spain, Italy, Greece, and France, to a lesser extent, has been attributed in numerous nutritional studies to the consumption of a Mediterranean-type diet. There are still many unresolved issues about the direct causal effect of the Mediterranean dietary regime on low incidence of coronary heart disease. An analysis of coronary heart disease mortality rates in Europe from a latitudinal gradient perspective has shown to have a close correlation to incident solar radiation. It is surmised that the resulting increased in situ biosynthesis of Vitamin D 3 could be the critical missing confounder in the analysis of the beneficial health outcome of the Mediterranean diet

  19. Relation between cancer incidence or mortality and external natural background radiation in Japan

    International Nuclear Information System (INIS)

    Ujeno, Y.

    1983-01-01

    Analysis was performed on the relationships between the organ dose-equivalent rate due to natural background radiation (mSv/a) and three parameters of cancer risk: the age-adjusted cancer incidence (patients x 10 5 persons x a -1 ) in 13 large areas, the standardized mortality ratio of cancers in 46 large areas, and the cancer mortality in the population aged more than 40 years old (cancer deaths x 10 5 persons x a -1 ) in 649 small areas. The age-adjusted liver cancer incidence in males fitted the exponential model significantly (p<0.01) and the relationship of stomach cancer mortality of aged males in small areas fitted the linear model significantly (p<0.05). No relationship was observed with regard to female cancer in either case. The relationships between the three parameters and various other cancers of both sexes were not statistically significant. (author)

  20. Current generation by monochromatic electromagnetic waves

    International Nuclear Information System (INIS)

    Belikov, V.S.; Kolesnichenko, Ya.I.; Plotnik, I.S.

    1983-01-01

    The generation of longitudinal currents in a magnetically confined plasma with travelling monochromatic electromagnetic waves of finite amplitude propagating at some angle to the external magnetic field is considered. By averaging over the particle cyclotron gyration period, the kinetic equation for the distribution function of electrons interacting with an electromagnetic wave is derived. This equation is solved for the case of low-frequency waves, on the assumption that the bounce period of electrons trapped by the wave field is small compared to the typical times of Coulomb collisions (in which case, the driving current is largest). From the solution obtained, analytic expressions for the driving current and the absorbed power, which are valid for a wide range of wave phase velocities, are found. The current drive method considered and the method using the wave packet are compared. (author)

  1. Causality of relationship between paternal radiation exposure and leukaemia incidence in the children of Sellafield workers

    International Nuclear Information System (INIS)

    Wheldon, T.E.; Mairs, R.J.; Barrett, A.

    1992-01-01

    In this letter the author comments on K.E. Baverstock's case (1991) against the likelihood of a causal relationship between reported leukemia incidence and paternal radiation dose in the children of Sellafield workers, and emphasizes the desirability of devising experimental tests of the germ-cell line damage hypothesis as well as the evaluation of its plausibility. Particular reference is made to the role played by dose-rates and by the two-hit model for childhood acute leukemia. (Letter to the Editor)

  2. Association of UV radiation with Parkinson disease incidence: A nationwide French ecologic study

    International Nuclear Information System (INIS)

    Kravietz, Adam; Kab, Sofiane; Wald, Lucien; Dugravot, Aline; Singh-Manoux, Archana; Moisan, Frédéric; Elbaz, Alexis

    2017-01-01

    Background: Vitamin D is thought to contribute to brain health, but it is unclear whether low vitamin D levels are associated with increased incidence of Parkinson's disease (PD). Using ultraviolet B (UV-B) as a surrogate for vitamin D levels, we conducted a nationwide ecologic study in France in order to examine the association of UV-B with PD incidence. Methods: We used French national drug claims databases to identify PD cases using a validated algorithm. UV-B data from the solar radiation database were derived from satellite images. We estimated PD incidence (2010–2012) at the canton level (small administrative French unit) and used multilevel Poisson regression to examine its association with UV-B (2005 annual average), after adjustment for age, sex, deprivation index, density of neurologists, smoking, proportion of agricultural land, and vitamin D supplementation. Results: Analyses are based on 69,010 incident PD patients. The association between UV-B and PD incidence was quadratic (P<0.001) and modified by age (P<0.001). Below 70y, incidence was higher in the bottom quintile (relative risk, RR Q1:45-49y =1.18, 95% CI=1.08–1.29) compared with the middle UV-B quintile, and lower in the top quintile (RR Q5:45-49y =0.85 [0.77–0.94]). An opposite pattern was observed in older subjects (RR Q1:85-89y =0.92 [0.89–0.96]; RR Q5:85-89y =1.06 [1.02–1.11]). Analysis based on continuous UV-B yielded similar conclusions. Conclusions: In this nationwide study, there was an age-dependent quadratic association between UV-B and PD incidence. This study suggests that reasonable UV-B exposure is associated with lower PD risk in younger persons and that future studies should examine dose-response relations and take age into account. - Highlights: • There is an age-dependent quadratic association between UV-B and PD incidence. • Reasonable UV-B exposure is beneficial in younger persons for the risk of PD. • Our findings are consistent with a role of vitamin D

  3. Association of UV radiation with Parkinson disease incidence: A nationwide French ecologic study

    Energy Technology Data Exchange (ETDEWEB)

    Kravietz, Adam [University of Miami Miller School of Medicine, Miami, Florida (United States); Kab, Sofiane [Santé publique France, Direction santé travail, F-94415 Saint-Maurice (France); CESP, Fac. de médecine - Univ. Paris-Sud, Fac. de médecine - UVSQ, INSERM, Université Paris-Saclay, 94805 Villejuif (France); Wald, Lucien [MINES ParisTech, PSL Research University, Sophia Antipolis (France); Dugravot, Aline [CESP, Fac. de médecine - Univ. Paris-Sud, Fac. de médecine - UVSQ, INSERM, Université Paris-Saclay, 94805 Villejuif (France); Singh-Manoux, Archana [CESP, Fac. de médecine - Univ. Paris-Sud, Fac. de médecine - UVSQ, INSERM, Université Paris-Saclay, 94805 Villejuif (France); Department of Epidemiology and Public Health, University College London, London (United Kingdom); Moisan, Frédéric [Santé publique France, Direction santé travail, F-94415 Saint-Maurice (France); Elbaz, Alexis, E-mail: alexis.elbaz@inserm.fr [Santé publique France, Direction santé travail, F-94415 Saint-Maurice (France); CESP, Fac. de médecine - Univ. Paris-Sud, Fac. de médecine - UVSQ, INSERM, Université Paris-Saclay, 94805 Villejuif (France)

    2017-04-15

    Background: Vitamin D is thought to contribute to brain health, but it is unclear whether low vitamin D levels are associated with increased incidence of Parkinson's disease (PD). Using ultraviolet B (UV-B) as a surrogate for vitamin D levels, we conducted a nationwide ecologic study in France in order to examine the association of UV-B with PD incidence. Methods: We used French national drug claims databases to identify PD cases using a validated algorithm. UV-B data from the solar radiation database were derived from satellite images. We estimated PD incidence (2010–2012) at the canton level (small administrative French unit) and used multilevel Poisson regression to examine its association with UV-B (2005 annual average), after adjustment for age, sex, deprivation index, density of neurologists, smoking, proportion of agricultural land, and vitamin D supplementation. Results: Analyses are based on 69,010 incident PD patients. The association between UV-B and PD incidence was quadratic (P<0.001) and modified by age (P<0.001). Below 70y, incidence was higher in the bottom quintile (relative risk, RR{sub Q1:45-49y}=1.18, 95% CI=1.08–1.29) compared with the middle UV-B quintile, and lower in the top quintile (RR{sub Q5:45-49y}=0.85 [0.77–0.94]). An opposite pattern was observed in older subjects (RR{sub Q1:85-89y}=0.92 [0.89–0.96]; RR{sub Q5:85-89y}=1.06 [1.02–1.11]). Analysis based on continuous UV-B yielded similar conclusions. Conclusions: In this nationwide study, there was an age-dependent quadratic association between UV-B and PD incidence. This study suggests that reasonable UV-B exposure is associated with lower PD risk in younger persons and that future studies should examine dose-response relations and take age into account. - Highlights: • There is an age-dependent quadratic association between UV-B and PD incidence. • Reasonable UV-B exposure is beneficial in younger persons for the risk of PD. • Our findings are consistent with a

  4. The monochromatic imaging mode of a RITA-type neutron spectrometer

    International Nuclear Information System (INIS)

    Bahl, C.R.H.; Andersen, P.; Klausen, S.N.; Lefmann, K.

    2004-01-01

    The imaging monochromatic mode of a neutron spectrometer with a multi-bladed RITA analyser system is so far unexplored. We present analytical calculations that define the mode. It is shown that the mode can be realised for PG (0 0 2) analyser crystals, from incident energies of about 3.2 meV and up, allowing the important cases of 3.7, 5.0 and 13.7 meV. Due to beam divergence, the neutron rays from neighbouring analyser blades are found to overlap slightly. Hence, the optimal use of the monochromatic imaging mode would be found by employing an adjustable radial collimator to limit the spread of the ray from each analyser blade

  5. The monochromatic imaging mode of a RITA-type neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bahl, C.R.H. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark) and Department of Physics, Technical University of Denmark, DK-2800 Lyngby (Denmark)]. E-mail: christian.bahl@risoe.dk; Andersen, P. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Niels Bohr Institute for Astronomy, Physics and Geophysics, University of Copenhagen, DK-2100 Copenhagen (Denmark); Klausen, S.N. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Lefmann, K. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)

    2004-12-01

    The imaging monochromatic mode of a neutron spectrometer with a multi-bladed RITA analyser system is so far unexplored. We present analytical calculations that define the mode. It is shown that the mode can be realised for PG (0 0 2) analyser crystals, from incident energies of about 3.2 meV and up, allowing the important cases of 3.7, 5.0 and 13.7 meV. Due to beam divergence, the neutron rays from neighbouring analyser blades are found to overlap slightly. Hence, the optimal use of the monochromatic imaging mode would be found by employing an adjustable radial collimator to limit the spread of the ray from each analyser blade.

  6. SU-E-T-208: Incidence Cancer Risk From the Radiation Treatment for Acoustic Neuroma Patient

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D [Kyung Hee University International Med. Serv., Seoul (Korea, Republic of); Chung, W [Kyung Hee University Hospital at Gangdong, Seoul, Seoul (Korea, Republic of); Shin, D [Kyung Hee University Hospital, Seoul, Seoul (Korea, Republic of); Yoon, M [Korea University, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: The present study aimed to compare the incidence risk of a secondary cancer from therapeutic doses in patients receiving intensitymodulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). Methods: Four acoustic neuroma patients were treated with IMRT, VMAT, or SRS. Their incidnece excess relative risk (ERR), excess absolute risk (EAR), and lifetime attributable risk (LAR) were estimated using the corresponding therapeutic doses measured at various organs by radio-photoluminescence glass dosimeters (RPLGD) placed inside a humanoid phantom. Results: When a prescription dose was delivered in the planning target volume of the 4 patients, the average organ equivalent doses (OED) at the thyroid, lung, normal liver, colon, bladder, prostate (or ovary), and rectum were measured. The OED decreased as the distance from the primary beam increased. The thyroid received the highest OED compared to other organs. A LAR were estimated that more than 0.03% of AN patients would get radiation-induced cancer. Conclusion: The tyroid was highest radiation-induced cancer risk after radiation treatment for AN. We found that LAR can be increased by the transmitted dose from the primary beam. No modality-specific difference in radiation-induced cancer risk was observed in our study.

  7. Molecular dynamics study of radiation damage and microstructure evolution of zigzag single-walled carbon nanotubes under carbon ion incidence

    Science.gov (United States)

    Li, Huan; Tang, Xiaobin; Chen, Feida; Huang, Hai; Liu, Jian; Chen, Da

    2016-07-01

    The radiation damage and microstructure evolution of different zigzag single-walled carbon nanotubes (SWCNTs) were investigated under incident carbon ion by molecular dynamics (MD) simulations. The radiation damage of SWCNTs under incident carbon ion with energy ranging from 25 eV to 1 keV at 300 K showed many differences at different incident sites, and the defect production increased to the maximum value with the increase in incident ion energy, and slightly decreased but stayed fairly stable within the majority of the energy range. The maximum damage of SWCNTs appeared when the incident ion energy reached 200 eV and the level of damage was directly proportional to incident ion fluence. The radiation damage was also studied at 100 K and 700 K and the defect production decreased distinctly with rising temperature because radiation-induced defects would anneal and recombine by saturating dangling bonds and reconstructing carbon network at the higher temperature. Furthermore, the stability of a large-diameter tube surpassed that of a thin one under the same radiation environments.

  8. Spectroscopic and bolometric measurements of radiation loss in DIVA

    International Nuclear Information System (INIS)

    Shiho, Makoto; Odajima, Kazuo; Sugie, Tatsuo; Maeda, Hikosuke; Kasai, Satoshi

    1977-11-01

    Radiation loss due to low- and high-z impurities in DIVA (JFT-2a) was measured by means of a calibrated 3m grazing incidence vacuum monochromater and a calibrated pyroelectric detector. The following results were obtained: 1) Radiation loss power due to low-z impurities becomes insignificant by using clean surfaces for the vacuum wall. 2) Radiation loss power due to pseudo continuum from high-z impurities has influence on the energy balance of the confined plasma. 3) The divertor reduces the radiation loss by a factor of about 3. (auth.)

  9. Spatial variation of natural radiation and childhood leukaemia incidence in Great Britain

    International Nuclear Information System (INIS)

    Richardson, Sylvia; Monfort, Christine; Green, Martyn; Muirhead, Colin; Draper, Gerald

    1995-01-01

    This paper describes an analysis of the geographical variation of childhood leukaemia incidence in Great Britain over a 15 year period in relation to natural radiation (gamma and radon). Data at the level of the 459 district level local authorities in England, Wales and regional districts in Scotland are analysed in two complementary ways: first, by Poisson regressions with the inclusion of environmental covariates and a smooth spatial structure; secondly, by a hierarchical Bayesian model in which extra-Poisson variability is modelled explicitly in terms of spatial and non-spatial components. From this analysis, we deduce a strong indication that a main part of the variability is accounted for by a local neighbourhood 'clustering' structure. This structure is furthermore relatively stable over the 15 year period for the lymphocytic leukaemias which make up the majority of observed cases. We found no evidence of a positive association of childhood leukaemia incidence with outdoor or indoor gamma radiation levels. There is no consistent evidence of any association with radon levels. Indeed, in the Poisson regressions, a significant positive association was only observed for one 5-year period, a result which is not compatible with a stable environmental effect. Moreover, this positive association became clearly non-significant when over-dispersion relative to the Poisson distribution was taken into account. (author)

  10. Unusual reflection of electromagnetic radiation from a stack of graphene layers at oblique incidence

    International Nuclear Information System (INIS)

    Bludov, Yu V; Peres, N M R; Vasilevskiy, M I

    2013-01-01

    We study the interaction of electromagnetic (EM) radiation with single-layer graphene and a stack of parallel graphene sheets at arbitrary angles of incidence. It is found that the behavior is qualitatively different for transverse magnetic (or p-polarized) and transverse electric (or s-polarized) waves. In particular, the absorbance of single-layer graphene attains a minimum (maximum) for the p (s)-polarization at the angle of total internal reflection when the light comes from a medium with a higher dielectric constant. In the case of equal dielectric constants of the media above and beneath graphene, for grazing incidence graphene is almost 100% transparent to p-polarized waves and acts as a tunable mirror for the s-polarization. These effects are enhanced for a stack of graphene sheets, so the system can work as a broad band polarizer. It is shown further that a periodic stack of graphene layers has the properties of a one-dimensional photonic crystal, with gaps (or stop bands) at certain frequencies. When an incident EM wave is reflected from this photonic crystal, the tunability of the graphene conductivity renders the possibility of controlling the gaps, and the structure can operate as a tunable spectral-selective mirror. (paper)

  11. A management plan for hospitals and medical centers facing radiation incidents

    Directory of Open Access Journals (Sweden)

    Fereshteh Davari

    2015-01-01

    Full Text Available Background: Nowadays, application of nuclear technology in different industries has largely expanded worldwide. Proportionately, the risk of nuclear incidents and the resulting injuries have, therefore, increased in recent years. Preparedness is an important part of the crisis management cycle; therefore efficient preplanning seems crucial to any crisis management plan. Equipped with facilities and experienced personnel, hospitals naturally engage with the response to disasters. The main purpose of our study was to present a practical management pattern for hospitals and medical centers in case they encounter a nuclear emergency. Materials and Methods: In this descriptive qualitative study, data were collected through experimental observations, sources like Safety manuals released by the International Atomic Energy Agency and interviews with experts to gather their ideas along with Delphi method for polling, and brainstorming. In addition, the 45 experts were interviewed on three targeted using brainstorming and Delphi method. Results: We finally proposed a management plan along with a set of practicality standards for hospitals and medical centers to optimally respond to nuclear medical emergencies when a radiation incident happens nearby. Conclusion: With respect to the great importance of preparedness against nuclear incidents adoption and regular practice of nuclear crisis management codes for hospitals and medical centers seems quite necessary.

  12. A management plan for hospitals and medical centers facing radiation incidents.

    Science.gov (United States)

    Davari, Fereshteh; Zahed, Arash

    2015-09-01

    Nowadays, application of nuclear technology in different industries has largely expanded worldwide. Proportionately, the risk of nuclear incidents and the resulting injuries have, therefore, increased in recent years. Preparedness is an important part of the crisis management cycle; therefore efficient preplanning seems crucial to any crisis management plan. Equipped with facilities and experienced personnel, hospitals naturally engage with the response to disasters. The main purpose of our study was to present a practical management pattern for hospitals and medical centers in case they encounter a nuclear emergency. In this descriptive qualitative study, data were collected through experimental observations, sources like Safety manuals released by the International Atomic Energy Agency and interviews with experts to gather their ideas along with Delphi method for polling, and brainstorming. In addition, the 45 experts were interviewed on three targeted using brainstorming and Delphi method. We finally proposed a management plan along with a set of practicality standards for hospitals and medical centers to optimally respond to nuclear medical emergencies when a radiation incident happens nearby. With respect to the great importance of preparedness against nuclear incidents adoption and regular practice of nuclear crisis management codes for hospitals and medical centers seems quite necessary.

  13. First Sub-arcsecond Collimation of Monochromatic Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Wagh, Apoorva G; Abbas, Sohrab; Treimer, Wolfgang, E-mail: nintsspd@barc.gov.in

    2010-11-01

    We have achieved the tightest collimation to date of a monochromatic neutron beam by diffracting neutrons from a Bragg prism, viz. a single crystal prism operating in the vicinity of Bragg incidence. An optimised silicon {l_brace}111{r_brace} Bragg prism has collimated 5.26A neutrons down to 0.58 arcsecond. In conjunction with a similarly optimised Bragg prism analyser of opposite asymmetry, this ultra-parallel beam yielded a 0.62 arcsecond wide rocking curve. This beam has produced the first SUSANS spectrum in Q {approx} 10{sup -6} A{sup -1} range with a hydroxyapatite casein protein sample and demonstrated the instrument capability of characterising agglomerates upto 150 {mu}m in size. The super-collimation has also enabled recording of the first neutron diffraction pattern from a macroscopic grating of 200 {mu}m period. An analysis of this pattern yielded the beam transverse coherence length of 175 {mu}m (FWHM), the greatest achieved to date for A wavelength neutrons.

  14. Sci-Fri AM: Quality, Safety, and Professional Issues 06: An Evaluation of Incident Reporting and Learning using the Canadian National System for Incident Reporting – Radiation Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Montgomery, Logan; Kildea, John [McGill University Health Centre (Canada)

    2016-08-15

    We report on the development and clinical deployment of an in-house incident reporting and learning system that implements the taxonomy of the Canadian National System for Incident Reporting – Radiation Treatment (NSIR-RT). In producing our new system, we aimed to: Analyze actual incidents, as well as potentially dangerous latent conditions. Produce recommendations on the NSIR-RT taxonomy. Incorporate features to divide reporting responsibility among clinical staff and expedite incident categorization within the NSIR-RT framework. Share anonymized incident data with the national database. Our multistep incident reporting workflow is focused around an initial report and a detailed follow-up investigation. An investigator, chosen at the time of reporting, is tasked with performing the investigation. The investigation feature is connected to our electronic medical records database to allow automatic field population and quick reference of patient and treatment information. Additional features include a robust visualization suite, as well as the ability to flag incidents for discussion at monthly Risk Management meetings and task ameliorating actions to staff. Our system was deployed into clinical use in January 2016. Over the first three months of use, 45 valid incidents were reported; 31 of which were reported as actual incidents as opposed to near-misses or reportable circumstances. However, we suspect there is ambiguity within our centre in determining the appropriate event type, which may be arising from the taxonomy itself. Preliminary trending analysis aided in revealing workflow issues pertaining to storage of treatment accessories and treatment planning delays. Extensive analysis will be undertaken as more data are accrued.

  15. Sci-Fri AM: Quality, Safety, and Professional Issues 06: An Evaluation of Incident Reporting and Learning using the Canadian National System for Incident Reporting – Radiation Treatment

    International Nuclear Information System (INIS)

    Montgomery, Logan; Kildea, John

    2016-01-01

    We report on the development and clinical deployment of an in-house incident reporting and learning system that implements the taxonomy of the Canadian National System for Incident Reporting – Radiation Treatment (NSIR-RT). In producing our new system, we aimed to: Analyze actual incidents, as well as potentially dangerous latent conditions. Produce recommendations on the NSIR-RT taxonomy. Incorporate features to divide reporting responsibility among clinical staff and expedite incident categorization within the NSIR-RT framework. Share anonymized incident data with the national database. Our multistep incident reporting workflow is focused around an initial report and a detailed follow-up investigation. An investigator, chosen at the time of reporting, is tasked with performing the investigation. The investigation feature is connected to our electronic medical records database to allow automatic field population and quick reference of patient and treatment information. Additional features include a robust visualization suite, as well as the ability to flag incidents for discussion at monthly Risk Management meetings and task ameliorating actions to staff. Our system was deployed into clinical use in January 2016. Over the first three months of use, 45 valid incidents were reported; 31 of which were reported as actual incidents as opposed to near-misses or reportable circumstances. However, we suspect there is ambiguity within our centre in determining the appropriate event type, which may be arising from the taxonomy itself. Preliminary trending analysis aided in revealing workflow issues pertaining to storage of treatment accessories and treatment planning delays. Extensive analysis will be undertaken as more data are accrued.

  16. High resolution monochromatic X-ray imaging system based on spherically bent crystals

    International Nuclear Information System (INIS)

    Aglitskiy, Y.; Lehecka, T.; Obenschain, S.; Bodner, S.; Pawley, C.; Gerber, K.; Sethian, J.; Brown, C.M.; Seely, J.; Feldman, U.; Holland, G.

    1997-01-01

    We have developed a new X-ray imaging system based on spherically curved crystals. It is designed and used for diagnostics of targets ablatively accelerated by the Nike KrF laser [1,2]. The imaging system is used for plasma diagnostics of the main target and for characterization of potential backlighters. A spherically curved quartz crystal (2d=6.687 Angstrom, R=200mm) is used to produce monochromatic backlit images with the He-like Si resonance line (1865 eV) as the source of radiation. The spatial resolution of the X-ray optical system is 3 endash 4 μm. Time resolved backlit monochromatic images of CH planar targets driven by the Nike facility have been obtained with 6 endash 7 μm spatial resolution. copyright 1997 American Institute of Physics

  17. High resolution monochromatic X-ray imaging system based on spherically bent crystals

    International Nuclear Information System (INIS)

    Aglitskiy, Y.; Lehecka, T.; Obenschain, S.; Bodner, S.; Pawley, C.; Gerber, K.; Sethian, J.; Brown, C. M.; Seely, J.; Feldman, U.; Holland, G.

    1997-01-01

    We have developed a new X-ray imaging system based on spherically curved crystals. It is designed and used for diagnostics of targets ablatively accelerated by the Nike KrF laser. The imaging system is used for plasma diagnostics of the main target and for characterization of potential backlighters. A spherically curved quartz crystal (2d=6.687 A, R=200 mm) is used to produce monochromatic backlit images with the He-like Si resonance line (1865 eV) as the source of radiation. The spatial resolution of the X-ray optical system is 3-4 μm. Time resolved backlit monochromatic images of CH planar targets driven by the Nike facility have been obtained with 6-7 μm spatial resolution

  18. High-resolution monochromatic x-ray imaging system based on spherically bent crystals

    International Nuclear Information System (INIS)

    Aglitskiy, Y.; Lehecka, T.; Obenschain, S.; Bodner, S.; Pawley, C.; Gerber, K.; Sethian, J.; Brown, C.M.; Seely, J.; Feldman, U.; Holland, G.

    1998-01-01

    We have developed an improved x-ray imaging system based on spherically curve crystals. It is designed and used for diagnostics of targets ablatively accelerated by the Nike KrF laser. A spherically curved quartz crystal (2d=6.687 Angstrom, R=200 mm) has been used to produce monochromatic backlit images with the He-like Si resonance line (1865 eV) as the source of radiation. The spatial resolution of the x-ray optical system is 1.7 μm in selected places and 2 - 3 μm over a larger area. Time-resolved backlit monochromatic images of polystyrene planar targets driven by the Nike facility have been obtained with a spatial resolution of 2.5 μm in selected places and 5 μm over the focal spot of the Nike laser. copyright 1998 Optical Society of America

  19. Can Angiotensin-Converting Enzyme Inhibitors Reduce the Incidence, Severity, and Duration of Radiation Proctitis?

    International Nuclear Information System (INIS)

    Alashkham, Abduelmenem; Paterson, Catherine; Rauchhaus, Petra; Nabi, Ghulam

    2016-01-01

    Purpose: To determine whether participants taking angiotensin-converting enzyme inhibitors (ACEIs) and treated with radical radiation therapy with neoadjuvant/adjuvant hormone therapy have less incidence, severity, and duration of radiation proctitis. Methods and Materials: A propensity score analysis of 817 patients who underwent radical radiation therapy with neoadjuvant or adjuvant hormone therapy as primary line management in a cohort study during 2009 to 2013 was conducted. Patients were stratified as follows: group 1, hypertensive patients taking ACEIs (as a study group); group 2, nonhypertensive patients not taking ACEIs; and group 3, hypertensive patients not taking ACEIs (both as control groups). The incidence, severity, and duration of proctitis were the main outcome. χ"2 tests, Mann-Whitney U tests, analysis of variance, risk ratio (RR), confidence interval (CI), Kaplan-Meier plots, and log-rank tests were used. Results: The mean age of the participants was 68.91 years, with a follow-up time of 3.38 years. Based on disease and age-matched comparison, there was a statistically significant difference of proctitis grading between the 3 groups: χ"2 (8, n=308) = 72.52, P<.001. The Mann-Whitney U test indicated that grades of proctitis were significantly lower in hypertensive patients taking ACEIs than in nonhypertensive patients not taking ACEIs and hypertensive patients not taking ACEIs (P<.001). The risk ratio (RR) of proctitis in hypertensive patients taking ACEIs was significantly lower than in hypertensive patients not taking ACEIs (RR 0.40, 95% CI 0.30-0.53, P<.001) and in nonhypertensive patients not taking ACEIs (RR 0.58, 95% CI 0.44-0.77, P<.001). Time to event analysis revealed that hypertensive patients taking ACEIs were significantly different from the control groups (P<.0001). Furthermore, hypertensive patients taking ACEIs had significantly faster resolution of proctitis (P<.0001). Conclusion: Patients who were taking ACEIs were

  20. Can Angiotensin-Converting Enzyme Inhibitors Reduce the Incidence, Severity, and Duration of Radiation Proctitis?

    Energy Technology Data Exchange (ETDEWEB)

    Alashkham, Abduelmenem, E-mail: alashkham@yahoo.com [Academic Section of Urology, Division of Cancer Research, School of Medicine, University of Dundee, Scotland (United Kingdom); Paterson, Catherine [Academic Section of Urology, Division of Cancer Research, School of Medicine, University of Dundee, Scotland (United Kingdom); Rauchhaus, Petra [Tayside Clinical Trials Unit, School of Medicine, University of Dundee, Scotland (United Kingdom); Nabi, Ghulam [Academic Section of Urology, Division of Cancer Research, School of Medicine, University of Dundee, Scotland (United Kingdom)

    2016-01-01

    Purpose: To determine whether participants taking angiotensin-converting enzyme inhibitors (ACEIs) and treated with radical radiation therapy with neoadjuvant/adjuvant hormone therapy have less incidence, severity, and duration of radiation proctitis. Methods and Materials: A propensity score analysis of 817 patients who underwent radical radiation therapy with neoadjuvant or adjuvant hormone therapy as primary line management in a cohort study during 2009 to 2013 was conducted. Patients were stratified as follows: group 1, hypertensive patients taking ACEIs (as a study group); group 2, nonhypertensive patients not taking ACEIs; and group 3, hypertensive patients not taking ACEIs (both as control groups). The incidence, severity, and duration of proctitis were the main outcome. χ{sup 2} tests, Mann-Whitney U tests, analysis of variance, risk ratio (RR), confidence interval (CI), Kaplan-Meier plots, and log-rank tests were used. Results: The mean age of the participants was 68.91 years, with a follow-up time of 3.38 years. Based on disease and age-matched comparison, there was a statistically significant difference of proctitis grading between the 3 groups: χ{sup 2} (8, n=308) = 72.52, P<.001. The Mann-Whitney U test indicated that grades of proctitis were significantly lower in hypertensive patients taking ACEIs than in nonhypertensive patients not taking ACEIs and hypertensive patients not taking ACEIs (P<.001). The risk ratio (RR) of proctitis in hypertensive patients taking ACEIs was significantly lower than in hypertensive patients not taking ACEIs (RR 0.40, 95% CI 0.30-0.53, P<.001) and in nonhypertensive patients not taking ACEIs (RR 0.58, 95% CI 0.44-0.77, P<.001). Time to event analysis revealed that hypertensive patients taking ACEIs were significantly different from the control groups (P<.0001). Furthermore, hypertensive patients taking ACEIs had significantly faster resolution of proctitis (P<.0001). Conclusion: Patients who were taking ACEIs were

  1. Role of radiation therapy in the management of plasma cell tumors. [Incidence of complications

    Energy Technology Data Exchange (ETDEWEB)

    Mill, W.B.; Griffith, R.

    1980-02-15

    A retrospective review is reported of 128 patients presenting with multiple myeloma and 16 patients presenting with solitary plasmacytoma. Ninety-one percent of 116 evaluable patients treated for palliation of painful bone disease received some degree of subjective pain relief. The radiation dose most frequently prescribed was between 1500 and 2000 rad. Of the 278 ports treated, only 17 (6.1%) were re-treated to the same area at a later date. There was no increase in incidence of re-treatment with lower radiation doses. Ten of the 13 patients treated for a solitary plasmacytoma with a minimum follow-up period of three years have local tumor control. The median survival in the solitary plasmacytomas is five and one-half years. Data from the literature on 27 additional solitary plasmacytomas combined with our data suggest an improved local control and a decrease in dissemination with doses greater than 5000 rad. It is concluded that low doses of radiation are usually adequate to treat painful bone lesions of multiple myeloma and doses of 5000 to 6500 rad in six to seven weeks are recommended for solitary plasmacytomas.

  2. X-ray radiation damage of organic semiconductor thin films during grazing incidence diffraction experiments

    Energy Technology Data Exchange (ETDEWEB)

    Neuhold, A., E-mail: alfred.neuhold@tugraz.at [Institute of Solid State Physics, Graz University of Technology, Graz (Austria); Novak, J.; Flesch, H.-G.; Moser, A.; Djuric, T. [Institute of Solid State Physics, Graz University of Technology, Graz (Austria); Grodd, L.; Grigorian, S.; Pietsch, U. [Institute of Physics, University Siegen (Germany); Resel, R. [Institute of Solid State Physics, Graz University of Technology, Graz (Austria)

    2012-08-01

    Since modern synchrotrons with highly intense X-ray beams are in use to investigate organic materials, the stability of soft matter materials during beam exposure is a crucial issue. Grazing incidence X-ray diffraction and specular X-ray reflectivity measurements were performed on thin films of organic semiconducting materials, like poly(3-hexylthiophene) (P3HT), sexithiophene and pentacene. These films were irradiated with an average flux density between 10{sup 15} and 10{sup 16} photons/(s mm{sup 2}) and evidenced a different stability in synchrotron X-ray radiation. The semi-crystalline P3HT showed a clear intensity decrease of the 1 0 0 Bragg peak and 0 2 0 Bragg peak compared to the rather stable diffraction features of the molecular crystals sexithiophene and pentacene. The difference in synchrotron X-ray radiation stability is explained by the interaction of the X-ray beam with the individual chemical components in the molecules as well as by the different crystallinities of the materials. Furthermore, the semi-crystalline P3HT film exhibited an increase of film thickness after irradiation and the surface roughness slightly decreased. To summarize, this study shows a strong influence of synchrotron X-ray radiation to specific organic thin films like e.g. P3HT, while others like pentacene and sexithiophene are observed as quite stable.

  3. Compton scattering and γ-quanta monochromatization

    International Nuclear Information System (INIS)

    Goryachev, B.I.; Shevchenko, V.G.

    1979-01-01

    The γ-quanta monochromatization method is proposed for sdudying high-excited states and mechanisms of nuclei photodisintegration. The method is based on the properties of photon Compton scattering. It permits to obtain high energy resolution without accurate analysis of the particle energies taking part in the scattering process. A possible design of the compton γ- monochromator is presented. The γ-quanta scatterer of the elements with a small nucleus charge (e.g. LiH) is placed inside the β-spectrometer of low resolution. The monochromator is expected to operate in the γ-beam of the high-current synchrotron, and it provides for a rather good energy resolution rho(W) while studying the high-excited nucleus states (rho(W) approximately 2% in the range of the giant dipole resonance). With the γ-quanta energy growth rho(W) increases as Wsup(0.6). The monochromator permits to obtain high statistical accuracy for a smaller period of time (at a considerably better energy resolution) than while working with a bremsstrahlung spectrum. The yield of quasimonochromatic photons related to the ΔW(ΔW = rho(W)W) range of energy resolution increases as Wsup(0.6). This fact makes it promjssing to use monochromator in the energy range considerably exceeding the characteristic energy of the gigantic dipole resonance

  4. Assessment of ionizing radiation as a risk factor for breast cancer incidence in Goiania

    International Nuclear Information System (INIS)

    Lage, Leonardo Bastos

    2016-01-01

    This research aims to evaluate whether exposure to ionizing radiation to which women are subjected can be associated with the incidence of breast cancer in Goiania. The defined study area is the central region of Goiania, or the Sanitary Districts of Campinas-Centro and Sul, in which are the seven major accident sources of contamination with Cesium 137, and also, as shown by previous study, the majority of new cases of breast cancer (60,43 %). We used the geographical division of the city in census tracts and health districts. The data collection was divided in two stages: the first, for the survey of radiometric measurements, and the second, for identifying the addresses of women diagnosed with breast cancer. The radiometric survey occurred between 2010 and 2014, in which was used an environmental gamma radiation mobile measuring system. This system was composed by a high-sensitivity detector coupled to a Global Positioning System (GPS) and a microcomputer. The assembly was installed on a motor vehicle so that the height of the detector is found at one meter from the ground, and programmed to obtain a measurement of the doses absorbed in the air rate each second. The data collected were: doses absorbed in the air rate, geographical coordinates, altitude, date and time of acquisition. From Mobisys software, files were generated and from ArcGIS 10.0 platform, geospatial assessment survey through the elaboration of thematic maps and geospatial analysis statistics. The annual averages of effective doses and collective effective doses were estimated from the rate of doses absorbed in air collected by the system and the resident population in the census tracts. The second stage begun from the data collection at the Registry of Goiania's Population Based Cancer (RCBPGO), in which were identified addresses of women diagnosed with breast cancer between 2001 and 2010. Part of the data was geographically referenced and using census data were estimated and compared the

  5. Survey on risk perception of radiation following an incident involving a stuck 60Co source in Henan Province, China

    International Nuclear Information System (INIS)

    Lei, C.; Sun, Q.; Cheng, X.; Zhang, Q.; Fu, Y.; Chu, C.; Zhao, Y.; Qin, W.; Su, X.

    2012-01-01

    In July 2009, an incident involving a stuck Co-60 source led hundreds of thousands of people to escape Qi County, Henan Province, China, although no medical or environmental consequences were related to the incident. To investigate knowledge about radiation, public risk-perception of radiation, and evaluation of the official response, a survey was conducted in Qi and Hui County (control). Face-to-face questionnaire interviews were conducted among three groups with different educational backgrounds. In total, 1340 valid questionnaires were collected from people interviewed. Knowledge about radiation was low in all groups in both counties, although knowledge in Qi County was higher than that in Hui County (control). More than 40 % respondents supported construction of nuclear power plants (NPPs) in China, while only a few supported constructing NPPs in their vicinity. The main reasons for the mass escape following the incident were assumed to be lack of knowledge about radiation, misinformation, the government's failure to disclose information in time and imitation of group behaviour. Over 60 % in Group I and II trusted the local government. About 64 % disapproved the response of the Qi County government. After the incident, the population in Qi County still knows little about radiation. Although people trust the government, they are dissatisfied with the response of the local government regarding the incident. (authors)

  6. Three-dimensional polarization states of monochromatic light fields.

    Science.gov (United States)

    Azzam, R M A

    2011-11-01

    The 3×1 generalized Jones vectors (GJVs) [E(x) E(y) E(z)](t) (t indicates the transpose) that describe the linear, circular, and elliptical polarization states of an arbitrary three-dimensional (3-D) monochromatic light field are determined in terms of the geometrical parameters of the 3-D vibration of the time-harmonic electric field. In three dimensions, there are as many distinct linear polarization states as there are points on the surface of a hemisphere, and the number of distinct 3-D circular polarization states equals that of all two-dimensional (2-D) polarization states on the Poincaré sphere, of which only two are circular states. The subset of 3-D polarization states that results from the superposition of three mutually orthogonal x, y, and z field components of equal amplitude is considered as a function of their relative phases. Interesting contours of equal ellipticity and equal inclination of the normal to the polarization ellipse with respect to the x axis are obtained in 2-D phase space. Finally, the 3×3 generalized Jones calculus, in which elastic scattering (e.g., by a nano-object in the near field) is characterized by the 3-D linear transformation E(s)=T E(i), is briefly introduced. In such a matrix transformation, E(i) and E(s) are the 3×1 GJVs of the incident and scattered waves and T is the 3×3 generalized Jones matrix of the scatterer at a given frequency and for given directions of incidence and scattering.

  7. Assessment of radiation doses due to normal operation, incidents and accidents of the final disposal facility

    International Nuclear Information System (INIS)

    Rossi, J.; Raiko, H.; Suolanen, V.; Ilvonen, M.

    1999-03-01

    Radiation doses for workers of the encapsulation and disposal facility and for inhabitants in the environment caused by the facility during its operation were considered. The study covers both the normal operation of the plant and some hypothetical incidents and accidents. Occupational radiation doses inside the plant during normal operation are based on the design basis, assuming that highest permitted dose levels are prevailing in control rooms during fuel transfer and encapsulation processes. Release through the ventilation stack is assumed to be filtered both in normal operation and in hypothetical incident and accident cases. Calculation of the offsite doses from normal operation is based on the hypothesis that one fuel pin per 100 fuel bundles for all batches of spent fuel transported to the encapsulation facility is leaking. The release magnitude in incidents and accidents is based on the event chains, which lead to loss of fuel pin tightness followed by a discharge of radionuclides into the handling chamber and to some degree through the ventilation stack into atmosphere. The weather data measured at the Olkiluoto meteorological mast was employed for calculating of offsite doses. Therefore doses could be calculated in a large amount of different dispersion conditions, the statistical frequencies of which have, been measured. Finally doses were combined into cumulative distributions, from which a dose value representing the 99.5 % confidence level, is presented. The dose values represent the exposure of a critical group, which is assumed to live at the distance of 200 meters from the encapsulation and disposal plant and thus it will receive the largest doses in most dispersion conditions. Exposure pathways considered were: cloudsnine, inhalation, groundshine and nutrition (milk of cow, meat of cow, green vegetables, grain and root vegetables). Nordic seasonal variation is included in ingestion dose models. The results obtained indicate that offsite doses

  8. High-flux normal incidence monochromator for circularly polarized synchrotron radiation

    International Nuclear Information System (INIS)

    Schaefers, F.; Peatman, W.; Eyers, A.; Heckenkamp, C.; Schoenhense, G.; Heinzmann, U.

    1986-01-01

    A 6.5-m normal incidence monochromator installed at the storage ring BESSY, which is optimized for a high throughput of circularly polarized off-plane radiation at moderate resolution is described. The monochromator employs two exit slits and is specially designed and used for low-signal experiments such as spin- and angle-resolved photoelectron spectroscopy on solids, adsorbates, free atoms, and molecules. The Monk--Gillieson mounting (plane grating in a convergent light beam) allows for large apertures with relatively little astigmatism. With two gratings, a flux of more than 10 11 photons s -1 bandwidth -1 (0.2--0.5 nm) with a circular polarization of more than 90% in the wavelength range from 35 to 675 nm is achieved

  9. Mirror and grating surface figure requirements for grazing incidence synchrotron radiation beamlines: Power loading effects

    Energy Technology Data Exchange (ETDEWEB)

    Hulbert, S.L.; Sharma, S.

    1987-01-01

    At present, grazing incidence mirrors are used almost exclusively as the first optical element in VUV and soft x-ray synchrotron radiation beamlines. The performance of these mirrors is determined by thermal and mechanical stress-induced figure errors as well as by figure errors remaining from the grinding and polishing process. With the advent of VUV and soft x-ray undulators and wigglers has come a new set of thermal stress problems related to both the magnitude and the spatial distribution of power from these devices. In many cases the power load on the entrance slits and gratings in these beamlines is no longer negligible. The dependence of thermally-induced front-end mirror figure errors on various storage ring and insertion device parameters (especially those at the National Synchrotron Light Source) and the effects of these figure errors on two classes of soft x-ray beamlines are presented.

  10. The incidence of other primary cancers in patients with an oral cancer treated with radiation therapy

    International Nuclear Information System (INIS)

    Shimizutani, Kiminari; Koseki, Yonoshin; Ikeda, Hiroshi

    1992-01-01

    From January 1980 through April 1990, a total of 317 patients with an oral cancer were treated with radiation therapy at Department of Radiology, Osaka University Hospital. Twenty-seven (8.5%) of these 317 patients had other primary cancers. For statistical purposes, the expected number of other primary cancers was estimated by multiplying the age-sex specific incidence rates among Osaka residents with the Person-year at risk figures, based on the Osaka Prefectural Cancer Registry. The observed/expected [0/E] ratios were 16.00 (p<0.01) for the esophagus and 28.42 (p<0.01) for the oropharynx. The present study suggested the necessity of following up oral cancer patients, especially those who have had carcinoma of the mouth floor, in order to enable the early diagnosis of upper digestive tract cancer. (author)

  11. Mark IV 'Grasshopper' grazing incidence mono-chromator for the Canadian Synchrotron Radiation Facility (CSRF)

    International Nuclear Information System (INIS)

    Tan, K.H.; Bancroft, G.M.; Coatsworth, L.L.; Yates, B.W.

    1982-01-01

    The vacuum, mechanical, and optical characteristics of a 'Grasshopper' grazing incidence monochromator for use with a synchrotron radiation source in the 30-300 eV range is described. The monochromator is compatible with ultrahigh vacuum ( -10 Torr throughout), and the motor driven scan mechanism is linear and reliable. The monchromator has been calibrated using several known absorption edges between 36 and 102 eV and a nonlinear least squares fit to the scan equation. These same absorption edges, plus a scan over zero order, show that the present resolution of the monochromator (with 10 and 16 μm exit and entrance slits respectively) is 0.16 A (0.06 eV at the AlLsub(2,3) edge). With 10 μm entrance and exit slits the resolution will be very close to the theoretical Δlambda = 0.083 A

  12. Solar ultraviolet radiation in Syria measurements and relationship with skin cancer incidence

    International Nuclear Information System (INIS)

    Othman, I; Baydon, S.A.; Dawood, S.

    1994-11-01

    Seasonal variations of solar UVB (285-320) and UVA (320-400) were measured in three sites in Syria (33-37 N sup O) for two years: 1992-1993. UVB measurements were performed using polysulphone films and Robertson-Berger meter, while UVA measurements were done by NVA intensity meter. Two sets of measurements were carried out : - Maximal daily doses three times a week (every other day) - Diurnal variations from sun-rise to sun-set every two hours twice a month (every fortnight). The biological consequences of ultraviolet radiation withreference to some epidemiological data of skin cancer incidence in Syria since 1980 were discussed .(author). 36 refs., 21 figs., 11 tabs

  13. Determination, through of thermoluminescence dosimetry, of the incident radiation in critical organs, during cephalometric radiographies

    International Nuclear Information System (INIS)

    Hipolito Junior, O. di; Goncalves, N.; Boscolo, F.N.; Montebelo Filho, A.

    1985-01-01

    The object of this paper was to value and to compare the doses of X-ray incident in critical orgas of patient and operator, during cephalometric radiography. Each patient was submited for two radiographics expositions. First of all, they use the followings factors: 85 kVp, 15 mA and 4/10 s of exposition; while of the second radiography the conditions were of 70 kVp, 15 mA and 1.2 s of exposition. The dosimetric method was the thermoluminescent through the LiF-700. Although the cephalometric radiographies showed similars qualities, in bot conditions where the equipment functioned, the situation of high voltage was noted small doses of radiation. (author) [pt

  14. A parameter quantifying radiation damping of bay oscillations excited by incident tsunamis

    Science.gov (United States)

    Endoh, Takahiro; Inazu, Daisuke; Waseda, Takuji; Hibiya, Toshiyuki

    2018-04-01

    The transient response of a bay with a narrow mouth to incident tsunamis is interpreted as the convolution of the input signal with the impulse response obtained by an inverse Fourier transform of the response curve of the oscillatory system with one degree of freedom. The rate of radiation damping associated with energy escaping seaward through the bay mouth is expressed in terms of the quality factor Q, which determines the decaying envelope of the impulse response. The value of Q of the resonant peak is approximated by the ratio of the resonant frequency ω0 to the bandwidth between frequencies at which the power spectral density of sea level within the bay drops to half of the peak value. Since the shape of the frequency power spectrum during the tsunami event is almost similar to that in the normal state in the neighborhood of ω0, Q can be estimated from sea level datasets in the normal state. Although the amplitude and phase of the impulse response need to be adjusted using the first crest or trough of the observed leading wave, this approach proves to work well in examining the transient responses of Miyako Bay and Kushimoto Bay on the Japanese Pacific coast to incident tsunamis.

  15. Recovery from Iridium-192 flakes of a radioactive source for industrial use after a radiation incident

    International Nuclear Information System (INIS)

    Cruz, W.H.; Zapata, L.A.

    2013-01-01

    The Iridium-192 ( 192 Ir) is the most used and ideal for industrial radiography applications, especially in petrochemical plants and pipelines and provides better contrast sensitivity for thick (25.4 mm). This source has constructive sealed double encapsulation, the internal capsule containing stainless steel to radioactive material in the form of flakes and welded with TIG process. The radiological incident happened at a gas station fuel sales in circumstances in which there was a homogeneity test welds a tank, the flakes or Ir-192 fell off his ponytail and left scattered over an area of 2 m 2 , some fell flat areas and other land so collected in lead shielding and metal container and ground source. Full recovery of the leaflets was performed at the Division of radioactive waste management (GRRA) gaining a total of 22 flakes with no radiation risk to staff performance and installation and the conclusion was reached that the misapplicaion of TIG welding was the main cause the incident. (author)

  16. Incidence of Leukoencephalopathy After Whole-Brain Radiation Therapy for Brain Metastases

    International Nuclear Information System (INIS)

    Ebi, Junko; Sato, Hisashi; Nakajima, Masaru; Shishido, Fumio

    2013-01-01

    Purpose: To evaluate the incidence of leukoencephalopathy after whole-brain radiation therapy (WBRT) in patients with brain metastases. Methods and Materials: We retrospectively reviewed 111 patients who underwent WBRT for brain metastases from April 2001 through March 2008 and had evaluable computed tomography (CT) and/or magnetic resonance imaging (MRI) at least 1 month after completion of WBRT. We evaluated the leukoencephalopathy according to the Common Terminology Criteria for Adverse Events, version 3.0. The patients who had brain tumor recurrence after WBRT were censored at the last follow-up CT or MRI without recurrence. To evaluate the risk factors for leukoencephalopathy, bivariate analysis was performed using a logistic regression analysis adjusted for follow-up time. Factors included in the analysis were age, gender, dose fractionation, 5-fluorouracil, methotrexate, cisplatin, and other chemotherapeutic agents. Results: The median age of the 111 patients was 60.0 years (range, 23-89 years). The median follow-up was 3.8 months (range, 1.0-38.1 months). Leukoencephalopathy developed in 23 of the 111 patients. Grades 1, 2, and 3 were observed in 8, 7, and 8 patients, respectively. The incidence was 34.4% (11 of 32), 42.9% (6 of 14), 66.7% (2 of 3), and 100% (2 of 2) of the patients who were followed up for ≥6, ≥12, ≥24, and ≥36 months, respectively. In the bivariate analysis, older age (≥65 years) was significantly correlated with higher risk of leukoencephalopathy (odds ratio 3.31; 95% confidence interval 1.15-9.50; P=.03). Conclusions: The incidence of leukoencephalopathy after WBRT was 34.4% with ≥6 months follow-up, and increased with longer follow-up. Older age was a significant risk factor. The schedule of WBRT for patients with brain metastases should be carefully determined, especially for favorable patients

  17. Infant Brain Tumors: Incidence, Survival, and the Role of Radiation Based on Surveillance, Epidemiology, and End Results (SEER) Data

    International Nuclear Information System (INIS)

    Bishop, Andrew J.; McDonald, Mark W.; Chang, Andrew L.; Esiashvili, Natia

    2012-01-01

    Purpose: To evaluate the incidence of infant brain tumors and survival outcomes by disease and treatment variables. Methods and Materials: The Surveillance, Epidemiology, and End Results (SEER) Program November 2008 submission database provided age-adjusted incidence rates and individual case information for primary brain tumors diagnosed between 1973 and 2006 in infants less than 12 months of age. Results: Between 1973 and 1986, the incidence of infant brain tumors increased from 16 to 40 cases per million (CPM), and from 1986 to 2006, the annual incidence rate averaged 35 CPM. Leading histologies by annual incidence in CPM were gliomas (13.8), medulloblastoma and primitive neuroectodermal tumors (6.6), and ependymomas (3.6). The annual incidence was higher in whites than in blacks (35.0 vs. 21.3 CPM). Infants with low-grade gliomas had the highest observed survival, and those with atypical teratoid rhabdoid tumors (ATRTs) or primary rhabdoid tumors of the brain had the lowest. Between 1979 and 1993, the annual rate of cases treated with radiation within the first 4 months from diagnosis declined from 20.5 CPM to <2 CPM. For infants with medulloblastoma, desmoplastic histology and treatment with both surgery and upfront radiation were associated with improved survival, but on multivariate regression, only combined surgery and radiation remained associated with improved survival, with a hazard ratio for death of 0.17 compared with surgery alone (p = 0.005). For ATRTs, those treated with surgery and upfront radiation had a 12-month survival of 100% compared with 24.4% for those treated with surgery alone (p = 0.016). For ependymomas survival was higher in patients treated in more recent decades (p = 0.001). Conclusion: The incidence of infant brain tumors has been stable since 1986. Survival outcomes varied markedly by histology. For infants with medulloblastoma and ATRTs, improved survival was observed in patients treated with both surgery and early radiation

  18. An evaluation of early countermeasures to reduce the risk of internal radiation exposure after the Fukushima nuclear incident in Japan.

    Science.gov (United States)

    Nomura, Shuhei; Tsubokura, Masaharu; Gilmour, Stuart; Hayano, Ryugo S; Watanabe, Yuni N; Kami, Masahiro; Kanazawa, Yukio; Oikawa, Tomoyoshi

    2016-05-01

    After a radiation-release incident, intake of radionuclides in the initial stage immediately following the incident may be the major contributor to total internal radiation exposure for individuals in affected areas. However, evaluation of early internal contamination risk is greatly lacking. This study assessed the relationship between initial stage evacuation/indoor sheltering and internal radiation contamination levels 4 months after the 2011 Fukushima nuclear incident in Japan and estimated potential pathways of the contamination. The study population comprised 525 participants in the internal radiation screening program at Minamisoma Municipal General Hospital, 23 km north of the Fukushima nuclear plant. The analysed dataset included the results of a screening performed in July 2011, 4 months after the incident, and of a questionnaire on early-incident response behaviours, such as sheltering indoors and evacuations, completed by participants. Association between such early countermeasures and internal contamination levels of cesium-134 were assessed using Tobit multiple regression analyses. Our study shows that individuals who evacuated to areas outside Fukushima Prefecture had similar contamination levels of cesium-134 to individuals who stayed in Fukushima (relative risk: 0.86; 95% confidence interval: 0.74-0.99). Time spent outdoors had no significant relationship with contamination levels. The effects of inhalation from radiological plumes released from the nuclear plant on total internal radiation contamination might be so low as to be undetectable by the whole-body counting unit used to examine participants. Given the apparent limited effectiveness of evacuation and indoor sheltering on internal contamination, the decision to implement such early responses to a radiation-release incident should be made by carefully balancing their potential benefits and health risks. © The Author 2015. Published by Oxford University Press. All rights reserved. For

  19. Mitotic effects of monochromatic ultraviolet radiation at 225, 265, and 280 nm on eleven stages of the cell cycle of the grasshopper neuroblast in culture. I. Overall retardation from the stage irradiated to nuclear membrane breakdown

    International Nuclear Information System (INIS)

    Carlson, J.G.

    1976-01-01

    Neuroblasts of Chortophaga viridifasciata (DeGeer) in culture were exposed to different doses of 225, 265, or 280 nm ultraviolet radiations at 11 different stages and substages of the mitotic cycle and individually selected cells were timed to breakdown of the nuclear membrane. Comparisons of the effectiveness of different wavelengths on the different stages were based on the dose that reduced the cell progression rate to 67 percent of normal (D 67 ) and the slope of the regression line, i.e., the control to treated time (C/T) ratio change/erg/mm 2 at the D 67 level. Cells of the prereplication period (metaphase + anaphase + early telophase) and the S phase (middle and late telophase + interphase + very early prophase) are equally sensitive to uv and contrast sharply with the much lower sensitivity of those in the postreplication period (early and middle prophase). This can best be interpreted if chromosomal DNA is the chromophore for uv-induced mitotic retardation. Cells in the prereplication period at exposure show no wavelength effect. In the S phase all stages except middle telophase and all stages combined are significantly more sensitive to 265 and 280 nm than to 225 nm. Of the postreplication stages, early prophase is retarded significantly more by 280 than by 225 or 265 nm. The C/T ratio/erg/mm 2 is greater after exposure to 265 nm at all prereplication and replication stages, but exhibits no consistent wavelength pattern during the postreplication period. Evidence based on the orientation of the neuroblast with respect to the uv-source suggests that the chromophore for mitotic retardation does not reside within the centrosome and related structures, but may be present, at least partly, in the nucleolus

  20. TU-D-201-04: Veracity of Data Elements in Radiation Oncology Incident Learning Systems

    International Nuclear Information System (INIS)

    Kapur, A; Evans, S; Brown, D; Ezzell, G; Hoopes, D; Dieterich, S; Kapetanovic, K; Tomlinson, C

    2016-01-01

    Purpose: Incident learning systems encompass volumes, varieties, values, and velocities of underlying data elements consistent with the V’s of big data. Veracity, the 5th V however exists only if there is high inter-rater reliability (IRR) within the data elements. The purpose of this work was to assess IRR in the nationally deployed RO-ILS: Radiation Oncology-Incident Learning System (R) sponsored by the American Society for Radiation Oncology (ASTRO) and the American Association of Physicists in Medicine (AAPM). Methods: Ten incident reports covering a wide range of scenarios were created in standardized narrative and video formats and disseminated to 67 volunteers of multiple disciplines from 26 institutions along with two published narratives from the International Commission of Radiological Protection to assess IRR on a nationally representative level. The volunteers were instructed to independently enter the associated data elements in a test version of RO-ILS over a 3-week period. All responses were aggregated into a spreadsheet to assess IRR using free-marginal kappa metrics. Results: 48 volunteers from 21 institutions completed all reports in the study period. The average kappa score for all raters across all critical data elements was 0.659 [range 0.326–1.000]. Statistically significant differences (p <0.05) were noted between reporters of different disciplines and raters with varying levels of experience. Kappa scores were high for event classification (0.781) and contributory factors (0.777) and low for likelihood-of-harm (0.326). IRR was highest among AAPM-ASTRO members (0.672) and lowest among trainees (0.463). Conclusion: A moderate-to-substantial level of IRR in RO-ILS was noted in this study. Although the number of events reviewed in this study was small, opportunities for improving the taxonomy for the lower scoring data elements as well as specific educational targets for training were identified by assessing data veracity quantitatively

  1. TU-D-201-04: Veracity of Data Elements in Radiation Oncology Incident Learning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Kapur, A [Northwell Health System, New Hyde Park, NY (United States); Evans, S [Yale University New Haven, CT (United States); Brown, D [University of California, San Diego, La Jolla, CA (United States); Ezzell, G [Mayo Clinic Arizona, Phoenix, AZ (United States); Hoopes, D [The University of California San Diego, San Diego, CA (United States); Dieterich, S [UC Davis Medical Center, Sacramento, CA (United States); Kapetanovic, K; Tomlinson, C [American Society for Radiation Oncology, Fairfax, VA (United States)

    2016-06-15

    Purpose: Incident learning systems encompass volumes, varieties, values, and velocities of underlying data elements consistent with the V’s of big data. Veracity, the 5th V however exists only if there is high inter-rater reliability (IRR) within the data elements. The purpose of this work was to assess IRR in the nationally deployed RO-ILS: Radiation Oncology-Incident Learning System (R) sponsored by the American Society for Radiation Oncology (ASTRO) and the American Association of Physicists in Medicine (AAPM). Methods: Ten incident reports covering a wide range of scenarios were created in standardized narrative and video formats and disseminated to 67 volunteers of multiple disciplines from 26 institutions along with two published narratives from the International Commission of Radiological Protection to assess IRR on a nationally representative level. The volunteers were instructed to independently enter the associated data elements in a test version of RO-ILS over a 3-week period. All responses were aggregated into a spreadsheet to assess IRR using free-marginal kappa metrics. Results: 48 volunteers from 21 institutions completed all reports in the study period. The average kappa score for all raters across all critical data elements was 0.659 [range 0.326–1.000]. Statistically significant differences (p <0.05) were noted between reporters of different disciplines and raters with varying levels of experience. Kappa scores were high for event classification (0.781) and contributory factors (0.777) and low for likelihood-of-harm (0.326). IRR was highest among AAPM-ASTRO members (0.672) and lowest among trainees (0.463). Conclusion: A moderate-to-substantial level of IRR in RO-ILS was noted in this study. Although the number of events reviewed in this study was small, opportunities for improving the taxonomy for the lower scoring data elements as well as specific educational targets for training were identified by assessing data veracity quantitatively

  2. Curved crystal x-ray optics for monochromatic imaging with a clinical source.

    Science.gov (United States)

    Bingölbali, Ayhan; MacDonald, C A

    2009-04-01

    Monochromatic x-ray imaging has been shown to increase contrast and reduce dose relative to conventional broadband imaging. However, clinical sources with very narrow energy bandwidth tend to have limited intensity and field of view. In this study, focused fan beam monochromatic radiation was obtained using doubly curved monochromator crystals. While these optics have been in use for microanalysis at synchrotron facilities for some time, this work is the first investigation of the potential application of curved crystal optics to clinical sources for medical imaging. The optics could be used with a variety of clinical sources for monochromatic slot scan imaging. The intensity was assessed and the resolution of the focused beam was measured using a knife-edge technique. A simulation model was developed and comparisons to the measured resolution were performed to verify the accuracy of the simulation to predict resolution for different conventional sources. A simple geometrical calculation was also developed. The measured, simulated, and calculated resolutions agreed well. Adequate resolution and intensity for mammography were predicted for appropriate source/optic combinations.

  3. Effects of radiation on the incidence of prostate cancer among Nagasaki atomic bomb survivors.

    Science.gov (United States)

    Kondo, Hisayoshi; Soda, Midori; Mine, Mariko; Yokota, Kenichi

    2013-10-01

    Atomic bomb survivors have been reported to have an increased risk of some cancers, especially leukemia. However, the risk of prostate cancer in atomic bomb survivors is not known to have been examined previously. This study examined the association between atomic bomb radiation and the incidence of prostate cancer among male Nagasaki atomic bomb survivors. The subjects were classified by distance from the hypocenter into a proximal group (bomb survivors who were alive in 1996. The Cox proportional hazard model was used to estimate the risk of prostate cancer development, with adjustment for age at atomic bomb explosion, attained age, smoking status, and alcohol consumption. Compared with the distal group, the proximal group had significant increased risks of total, localized, and high-grade prostate cancer (relative risk and 95% confidence interval: 1.51 [1.21-1.89]; 1.80 [1.26-2.57]; and 1.88 [1.20-2.94], respectively). This report is the first known to reveal a significant relationship between atomic bomb radiation and prostate cancer. © 2013 Japanese Cancer Association.

  4. Electromagnetic radiation of electrons in periodic structures

    International Nuclear Information System (INIS)

    Potylitsyn, Alexander Petrovich

    2011-01-01

    Periodic magnetic structures (undulators) are widely used in accelerators to generate monochromatic undulator radiation (UR) in the range from far infrared to the hard X-ray region. Another periodic crystalline structure is used to produce quasimonochromatic polarized photon beams via the coherent bremsstrahlung mechanism (CBS). Due to such characteristics as monochromaticity, polarization and adjustability, these types of radiation is of large interest for applied and basic research of accelerator-emitted radiation. The book provides a detailed overview of the fundamental principles behind electromagnetic radiation emitted from accelerated charged particles (e.g. UR, CBS, radiation of fast electrons in Laser flash fields) as well as a unified description of relatively new radiation mechanisms which attracted great interest in recent years. This are the so-called polarization radiation excited by the Coulomb field of incident particles in periodic structures, parametric X-rays, resonant transition radiation and the Smith-Purcell effect. Characteristics of such radiation sources and perspectives of their usage are discussed. The recent experimental results as well as their interpretation are presented. (orig.)

  5. Infant brain tumors: incidence, survival, and the role of radiation based on Surveillance, Epidemiology, and End Results (SEER) Data.

    Science.gov (United States)

    Bishop, Andrew J; McDonald, Mark W; Chang, Andrew L; Esiashvili, Natia

    2012-01-01

    To evaluate the incidence of infant brain tumors and survival outcomes by disease and treatment variables. The Surveillance, Epidemiology, and End Results (SEER) Program November 2008 submission database provided age-adjusted incidence rates and individual case information for primary brain tumors diagnosed between 1973 and 2006 in infants less than 12 months of age. Between 1973 and 1986, the incidence of infant brain tumors increased from 16 to 40 cases per million (CPM), and from 1986 to 2006, the annual incidence rate averaged 35 CPM. Leading histologies by annual incidence in CPM were gliomas (13.8), medulloblastoma and primitive neuroectodermal tumors (6.6), and ependymomas (3.6). The annual incidence was higher in whites than in blacks (35.0 vs. 21.3 CPM). Infants with low-grade gliomas had the highest observed survival, and those with atypical teratoid rhabdoid tumors (ATRTs) or primary rhabdoid tumors of the brain had the lowest. Between 1979 and 1993, the annual rate of cases treated with radiation within the first 4 months from diagnosis declined from 20.5 CPM to incidence of infant brain tumors has been stable since 1986. Survival outcomes varied markedly by histology. For infants with medulloblastoma and ATRTs, improved survival was observed in patients treated with both surgery and early radiation compared with those treated with surgery alone. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. [Monochromatic aberration in accommodation. Dynamic wavefront analysis].

    Science.gov (United States)

    Fritzsch, M; Dawczynski, J; Jurkutat, S; Vollandt, R; Strobel, J

    2011-06-01

    Monochromatic aberrations may influence the visual acuity of the eye. They are not stable and can be affected by different factors. The subject of the following paper is the dynamic investigation of the changes in wavefront aberration with accommodation. Dynamic measurement of higher and lower order aberrations was performed with a WASCA Wavefront Analyzer (Carl-Zeiss-Meditec) and a specially constructed target device for aligning objects in far and near distances on 25 subjects aged from 15 to 27 years old. Wavefront aberrations showed some significant changes in accommodation. In addition to the characteristic sphere reaction accompanying miosis and changes in horizontal prism (Z(1) (1)) in the sense of a convergence movement of the eyeball also occurred. Furthermore defocus rose (Z(2) (0)) and astigmatism (Z(2) (-2)) changed. In higher-order aberrations a decrease in coma-like Zernike polynomials (Z(3) (-1), Z(3) (1)) was found. The most obvious change appeared in spherical aberration (Z(4) (0)) which increased and changed from positive to negative. In addition the secondary astigmatism (Z(4) (-2)) and quadrafoil (Z(4) (4)) rise also increased. The total root mean square (RMS), as well as the higher-order aberrations (RMS-HO) significantly increased in accommodation which is associated with a theoretical reduction of visual acuity. An analysis of the influence of pupil size on aberrations showed significant increases in defocus, spherical aberration, quadrafoil, RMS and RMS HO by increasing pupil diameter. By accommodation-associated miosis, the growing aberrations are partially compensated by focusing on near objects. Temporal analysis of the accommodation process with dynamic wavefront analysis revealed significant delays in pupil response and changing of prism in relation to the sphere reaction. In accommodation to near objects a discrete time ahead of third order aberrations in relation to the sphere response was found. Using dynamic wavefront measurement

  7. Ambient ultraviolet radiation exposure and hepatocellular carcinoma incidence in the United States.

    Science.gov (United States)

    VoPham, Trang; Bertrand, Kimberly A; Yuan, Jian-Min; Tamimi, Rulla M; Hart, Jaime E; Laden, Francine

    2017-08-18

    Hepatocellular carcinoma (HCC), the most commonly occurring type of primary liver cancer, has been increasing in incidence worldwide. Vitamin D, acquired from sunlight exposure, diet, and dietary supplements, has been hypothesized to impact hepatocarcinogenesis. However, previous epidemiologic studies examining the associations between dietary and serum vitamin D reported mixed results. The purpose of this study was to examine the association between ambient ultraviolet (UV) radiation exposure and HCC risk in the U.S. The Surveillance, Epidemiology, and End Results (SEER) database provided information on HCC cases diagnosed between 2000 and 2014 from 16 population-based cancer registries across the U.S. Ambient UV exposure was estimated by linking the SEER county with a spatiotemporal UV exposure model using a geographic information system. Poisson regression with robust variance estimation was used to calculate incidence rate ratios (IRRs) and 95% confidence intervals (CIs) for the association between ambient UV exposure per interquartile range (IQR) increase (32.4 mW/m 2 ) and HCC risk adjusting for age at diagnosis, sex, race, year of diagnosis, SEER registry, and county-level information on prevalence of health conditions, lifestyle, socioeconomic, and environmental factors. Higher levels of ambient UV exposure were associated with statistically significant lower HCC risk (n = 56,245 cases; adjusted IRR per IQR increase: 0.83, 95% CI 0.77, 0.90; p ambient UV and HCC risk was observed among males (p for interaction = 0.01) and whites (p for interaction = 0.01). Higher ambient UV exposure was associated with a decreased risk of HCC in the U.S. UV exposure may be a potential modifiable risk factor for HCC that should be explored in future research.

  8. Incidence, causative mechanisms, and anatomic localization of stroke in pituitary adenoma patients treated with postoperative radiation therapy versus surgery alone

    NARCIS (Netherlands)

    Sattler, Margriet; Vroomen, Patrick; Sluiter, Wim J.; Schers, Henk J.; van den Berg, Gerrit; Langendijk, Johannes A.; Wolffenbuttel, Bruce H. R.; van den Bergh, Alphons C. M.; van Beek, Andre P.

    2013-01-01

    PURPOSE: To assess and compare the incidence of stroke and stroke subtype in pituitary adenoma patients treated with postoperative radiation therapy (RT) and surgery alone. METHODS AND MATERIALS: A cohort of 462 pituitary adenoma patients treated between 1959 and 2008 at the University Medical

  9. Inhibition of motility in the cyanobacterium, Phormidium uncinatum, by solar and monochromatic UV irradiation

    International Nuclear Information System (INIS)

    Häder, D.P.; Watanabe, M.; Furuya, M.

    1986-01-01

    The effect of solar radiation and monochromatic UV radiation on the motility of the filamentous cyanobacterium Phormidium uncinatum was determined. Solar radiation (mid-day, in midsummer at a location near Lisboa, Portugal) was found to impair motility within about 30 min. This effect is neither a result of a temperature increase nor of visible light. The spectral sensitivity determined using the Okazaki Largé Spectrograph shows the maximal effectiveness of radiation of ≤300 nm. The short time requirement for the response and the lack of any photoreactivation of motility argues against DNA being the UV target. Investigations using reagents diagnostic of superoxide free radicals and singlet oxygen failed to confirm the involvement of photodynamic effects as the molecular mechanism causing UV inhibition of motility

  10. Variations with time and age in the relative risks of solid cancer incidence after radiation exposure

    International Nuclear Information System (INIS)

    Little, M.P.; Muirhead, C.R.; de Vathaire, F.; Charles, M.W.

    1997-01-01

    The Japanese atomic bomb survivor cancer incidence dataset and data on five groups exposed to radiation for medical reasons in childhood are analysed and evidence found for a reduction in the radiation-induced relative risk of cancers other than leukaemia with increasing time since exposure and age at exposure. The rate of the reductions in relative risk with time since exposure are not significantly different for those exposed in childhood and for those exposed in adulthood, if adjustment is made for the effects on the relative risk of age at exposure. For those irradiated in childhood, there is a statistically significant annual reduction of 5.8% (95% Cl 2.8, 8.9) in excess relative risk, and there are no strong indications of inter-cohort heterogeniety in the speed of reduction of relative risk. After adjustment for the effects of age at exposure, there is a significant annual reduction of 3.6% (95% Cl 1.6, 5.6) in excess relative risk in all age-at-exposure groups. There are significant reductions of 5.2% (95% Cl 3.7, 6.8) in excess relative risk per year of age at exposure. There are statistically significant (P = 0.04) interactions between the exponential adjustments to the excess relative risk for age at exposure and time since exposure in the Japanese data, but no indications (P = 0.38) of such interactions when powers of time since exposure and attained age are used to adjust the excess relative risk, so that the fit of the model with power adjustments is to be preferred to that of the model with exponential adjustments. (author)

  11. Development of highly polished, grazing incidence mirrors for synchrotron radiation beam lines at SSRL

    Energy Technology Data Exchange (ETDEWEB)

    Tirsell, K.G.; Berglin, E.J.; Fuchs, B.A.; Holdener, F.R.; Humpal, H.H.; Karpenko, V.P.; Kulkarni, S.; Fantone, S.D.

    1987-08-01

    New platinum-coated grazing incidence mirrors with low surface roughnesses have been developed to focus bending magnet radiation from the SSRL/SLAC SPEAR storage ring on the entrance slits of two Beam Line VIII grating monochromators. The first mirror in the toroidal grating monochromator (TGM) branch is a cooled SiC cylinder capable of absorbing synchrotron radiation power levels of up to 260 watts without excessive distortion. This mirror deflects the beam vertically through a 12/degree/ angle and focuses it sagitally on the TGM entrance slit plane. The second TGM optical element is a fused-silica spherical mirror with a large radius of curvature that deflects the beam vertically through an additional 12/degree/ and focuses it tangentially with 3/1 demagnification. The first mirror in our spherical grating branch is a 5/degree/-vertically deflecting, cooled SiC toroid designed to focus tangentially on the monochromator entrance slits and sagitally in the exit slits. A 4/degree/-deflecting fused silica mirror is used after the exit sites in each beam line to refocus on to the sample. For this application a thin cylinder is bent to approximate an ellipsoid. The mirrors are now installed at SSRL and performance measurements are planned. Qualitatively the focus of the TGM optics at the entrance slit plane appears very good. In this paper we discuss considerations leading to the choice of SiC for each of the two first mirrors. We present highlights of the development of these mirrors with some emphasis on SiC polishing techniques. In addition, the specialized metrology developed to produce the more difficult figure of the toroid will be described. Measured surface roughness and figure results will be presented. 19 refs., 11 figs.

  12. Development of highly polished, grazing incidence mirrors for synchrotron radiation beam lines at SSRL

    International Nuclear Information System (INIS)

    Tirsell, K.G.; Berglin, E.J.; Fuchs, B.A.; Holdener, F.R.; Humpal, H.H.; Karpenko, V.P.; Kulkarni, S.; Fantone, S.D.

    1987-08-01

    New platinum-coated grazing incidence mirrors with low surface roughnesses have been developed to focus bending magnet radiation from the SSRL/SLAC SPEAR storage ring on the entrance slits of two Beam Line VIII grating monochromators. The first mirror in the toroidal grating monochromator (TGM) branch is a cooled SiC cylinder capable of absorbing synchrotron radiation power levels of up to 260 watts without excessive distortion. This mirror deflects the beam vertically through a 12/degree/ angle and focuses it sagitally on the TGM entrance slit plane. The second TGM optical element is a fused-silica spherical mirror with a large radius of curvature that deflects the beam vertically through an additional 12/degree/ and focuses it tangentially with 3/1 demagnification. The first mirror in our spherical grating branch is a 5/degree/-vertically deflecting, cooled SiC toroid designed to focus tangentially on the monochromator entrance slits and sagitally in the exit slits. A 4/degree/-deflecting fused silica mirror is used after the exit sites in each beam line to refocus on to the sample. For this application a thin cylinder is bent to approximate an ellipsoid. The mirrors are now installed at SSRL and performance measurements are planned. Qualitatively the focus of the TGM optics at the entrance slit plane appears very good. In this paper we discuss considerations leading to the choice of SiC for each of the two first mirrors. We present highlights of the development of these mirrors with some emphasis on SiC polishing techniques. In addition, the specialized metrology developed to produce the more difficult figure of the toroid will be described. Measured surface roughness and figure results will be presented. 19 refs., 11 figs

  13. Enhancing monochromatic multipole emission by a subwavelength enclosure of degenerate Mie resonances

    KAUST Repository

    Zhao, Jiajun

    2017-07-06

    Sound emission is inefficient at low frequencies as limited by source size. This letter presents enhancing emission of monochromatic monopole and multipole sources by enclosing the source with a subwavelength circular enclosure filled of an anisotropic material of a low radial sound speed. The anisotropy is associated with an infinite tangential density along the azimuth. Numerical simulations show that emission gain is produced at frequencies surrounding degenerate Mie resonant frequencies of the enclosure, and meanwhile the radiation directivity pattern is well preserved. The degeneracy is theoretically analyzed. A realization of the material is suggested by using a space-coiling structure.

  14. Local Adaptive Calibration of the GLASS Surface Incident Shortwave Radiation Product Using Smoothing Spline

    Science.gov (United States)

    Zhang, X.; Liang, S.; Wang, G.

    2015-12-01

    Incident solar radiation (ISR) over the Earth's surface plays an important role in determining the Earth's climate and environment. Generally, can be obtained from direct measurements, remotely sensed data, or reanalysis and general circulation models (GCMs) data. Each type of product has advantages and limitations: the surface direct measurements provide accurate but sparse spatial coverage, whereas other global products may have large uncertainties. Ground measurements have been normally used for validation and occasionally calibration, but transforming their "true values" spatially to improve the satellite products is still a new and challenging topic. In this study, an improved thin-plate smoothing spline approach is presented to locally "calibrate" the Global LAnd Surface Satellite (GLASS) ISR product using the reconstructed ISR data from surface meteorological measurements. The influences of surface elevation on ISR estimation was also considered in the proposed method. The point-based surface reconstructed ISR was used as the response variable, and the GLASS ISR product and the surface elevation data at the corresponding locations as explanatory variables to train the thin plate spline model. We evaluated the performance of the approach using the cross-validation method at both daily and monthly time scales over China. We also evaluated estimated ISR based on the thin-plate spline method using independent ground measurements at 10 sites from the Coordinated Enhanced Observation Network (CEON). These validation results indicated that the thin plate smoothing spline method can be effectively used for calibrating satellite derived ISR products using ground measurements to achieve better accuracy.

  15. Incidence of radiation pneumonitis after thoracic irradiation: Dose-volume correlates

    International Nuclear Information System (INIS)

    Schallenkamp, John M.; Miller, Robert C.; Brinkmann, Debra H.; Foote, Tyler; Garces, Yolanda I.

    2007-01-01

    Purpose: To define clinical and dosimetric parameters correlated with the risk of clinically relevant radiation pneumonitis (RP) after thoracic radiotherapy. Methods and Materials: Records of consecutive patients treated with definitive thoracic radiotherapy were retrospectively reviewed for the incidence of RP of Grade 2 or greater by the Common Toxicity Criteria. Dose-volume histograms using total lung volume (TL) and TL minus gross tumor volume (TL-G) were created with and without heterogeneity corrections. Mean lung dose (MLD), effective lung volume (V eff ), and percentage of TL or TL-G receiving greater than or equal to 10, 13, 15, 20, and 30 Gy (V10-V30, respectively) were analyzed by logistic regression. Receiver operating characteristic (ROC) curves were generated to estimate RP predictive values. Results: Twelve cases of RP were identified in 92 eligible patients. Mean lung dose, V10, V13, V15, V20, and V eff were significantly correlated to RP. Combinations of MLD, V eff , V20, and V30 lost significance using TL-G and heterogeneity corrections. Receiver operating characteristic analysis determined V10 and V13 as the best predictors of RP risk, with a decrease in predictive value above those volumes. Conclusions: Intrathoracic radiotherapy should be planned with caution when using radiotherapy techniques delivering doses of 10 to 15 Gy to large lung volumes

  16. Incidence, Causative Mechanisms, and Anatomic Localization of Stroke in Pituitary Adenoma Patients Treated With Postoperative Radiation Therapy Versus Surgery Alone

    Energy Technology Data Exchange (ETDEWEB)

    Sattler, Margriet G.A., E-mail: g.a.sattler@umcg.nl [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON (Canada); Vroomen, Patrick C. [Department of Neurology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Sluiter, Wim J. [Department of Endocrinology and Metabolic Diseases, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Schers, Henk J. [Department of Primary and Community Care, Radboud University Nijmegen Medical Centre (Netherlands); Berg, Gerrit van den [Department of Endocrinology and Metabolic Diseases, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Langendijk, Johannes A. [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Wolffenbuttel, Bruce H.R. [Department of Endocrinology and Metabolic Diseases, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Bergh, Alphons C.M. van den [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Beek, André P. van [Department of Endocrinology and Metabolic Diseases, University of Groningen, University Medical Center Groningen, Groningen (Netherlands)

    2013-09-01

    Purpose: To assess and compare the incidence of stroke and stroke subtype in pituitary adenoma patients treated with postoperative radiation therapy (RT) and surgery alone. Methods and Materials: A cohort of 462 pituitary adenoma patients treated between 1959 and 2008 at the University Medical Center Groningen in The Netherlands was studied. Radiation therapy was administered in 236 patients. The TOAST (Trial of ORG 10172 in Acute Stroke Treatment) and the Oxfordshire Community Stroke Project classification methods were used to determine causative mechanism and anatomic localization of stroke. Stroke incidences in patients treated with RT were compared with that observed after surgery alone. Risk factors for stroke incidence were studied by log–rank test, without and with stratification for other significant risk factors. In addition, the stroke incidence was compared with the incidence rate in the general Dutch population. Results: Thirteen RT patients were diagnosed with stroke, compared with 12 surgery-alone patients. The relative risk (RR) for stroke in patients treated with postoperative RT was not significantly different compared with surgery-alone patients (univariate RR 0.62, 95% confidence interval [CI] 0.28-1.35, P=.23). Stroke risk factors were coronary or peripheral artery disease (univariate and multivariate RR 10.4, 95% CI 4.7-22.8, P<.001) and hypertension (univariate RR 3.9, 95% CI 1.6-9.8, P=.002). There was no difference in TOAST and Oxfordshire classification of stroke. In this pituitary adenoma cohort 25 strokes were observed, compared with 16.91 expected (standard incidence ratio 1.48, 95% CI 1.00-1.96, P=.049). Conclusions: In pituitary adenoma patients, an increased incidence of stroke was observed compared with the general population. However, postoperative RT was not associated with an increased incidence of stroke or differences in causative mechanism or anatomic localization of stroke compared with surgery alone. The primary stroke risk

  17. Incidence, Causative Mechanisms, and Anatomic Localization of Stroke in Pituitary Adenoma Patients Treated With Postoperative Radiation Therapy Versus Surgery Alone

    International Nuclear Information System (INIS)

    Sattler, Margriet G.A.; Vroomen, Patrick C.; Sluiter, Wim J.; Schers, Henk J.; Berg, Gerrit van den; Langendijk, Johannes A.; Wolffenbuttel, Bruce H.R.; Bergh, Alphons C.M. van den; Beek, André P. van

    2013-01-01

    Purpose: To assess and compare the incidence of stroke and stroke subtype in pituitary adenoma patients treated with postoperative radiation therapy (RT) and surgery alone. Methods and Materials: A cohort of 462 pituitary adenoma patients treated between 1959 and 2008 at the University Medical Center Groningen in The Netherlands was studied. Radiation therapy was administered in 236 patients. The TOAST (Trial of ORG 10172 in Acute Stroke Treatment) and the Oxfordshire Community Stroke Project classification methods were used to determine causative mechanism and anatomic localization of stroke. Stroke incidences in patients treated with RT were compared with that observed after surgery alone. Risk factors for stroke incidence were studied by log–rank test, without and with stratification for other significant risk factors. In addition, the stroke incidence was compared with the incidence rate in the general Dutch population. Results: Thirteen RT patients were diagnosed with stroke, compared with 12 surgery-alone patients. The relative risk (RR) for stroke in patients treated with postoperative RT was not significantly different compared with surgery-alone patients (univariate RR 0.62, 95% confidence interval [CI] 0.28-1.35, P=.23). Stroke risk factors were coronary or peripheral artery disease (univariate and multivariate RR 10.4, 95% CI 4.7-22.8, P<.001) and hypertension (univariate RR 3.9, 95% CI 1.6-9.8, P=.002). There was no difference in TOAST and Oxfordshire classification of stroke. In this pituitary adenoma cohort 25 strokes were observed, compared with 16.91 expected (standard incidence ratio 1.48, 95% CI 1.00-1.96, P=.049). Conclusions: In pituitary adenoma patients, an increased incidence of stroke was observed compared with the general population. However, postoperative RT was not associated with an increased incidence of stroke or differences in causative mechanism or anatomic localization of stroke compared with surgery alone. The primary stroke risk

  18. Comment on "Collision monochromatization in e+e- colliders"

    Science.gov (United States)

    Shatilov, D.

    2018-02-01

    Bogomyagkov and Levichev [Phys. Rev. Accel. Beams 20, 051001 (2017), 10.1103/PhysRevAccelBeams.20.051001] have recently reported on monochromatization in collision schemes with crossing angle. From their results, in particular, it may seem that: (1) horizontal dispersion at the IP can provide monochromatization factor Λ ≫1 while retaining Piwinski angle ϕ >1 , (2) production rate in such a scheme for FCC-ee at 62.5 GeV can be larger than that in the nominal crab waist collision, and (3) strong rf focusing can be used for monochromatization purposes. We demonstrate here that the first two statements are not correct, and the last one is very doubtful.

  19. Adverse radiation effect after stereotactic radiosurgery for brain metastases: incidence, time course, and risk factors.

    Science.gov (United States)

    Sneed, Penny K; Mendez, Joe; Vemer-van den Hoek, Johanna G M; Seymour, Zachary A; Ma, Lijun; Molinaro, Annette M; Fogh, Shannon E; Nakamura, Jean L; McDermott, Michael W

    2015-08-01

    The authors sought to determine the incidence, time course, and risk factors for overall adverse radiation effect (ARE) and symptomatic ARE after stereotactic radiosurgery (SRS) for brain metastases. All cases of brain metastases treated from 1998 through 2009 with Gamma Knife SRS at UCSF were considered. Cases with less than 3 months of follow-up imaging, a gap of more than 8 months in imaging during the 1st year, or inadequate imaging availability were excluded. Brain scans and pathology reports were reviewed to ensure consistent scoring of dates of ARE, treatment failure, or both; in case of uncertainty, the cause of lesion worsening was scored as indeterminate. Cumulative incidence of ARE and failure were estimated with the Kaplan-Meier method with censoring at last imaging. Univariate and multivariate Cox proportional hazards analyses were performed. Among 435 patients and 2200 brain metastases evaluable, the median patient survival time was 17.4 months and the median lesion imaging follow-up was 9.9 months. Calculated on the basis of 2200 evaluable lesions, the rates of treatment failure, ARE, concurrent failure and ARE, and lesion worsening with indeterminate cause were 9.2%, 5.4%, 1.4%, and 4.1%, respectively. Among 118 cases of ARE, approximately 60% were symptomatic and 85% occurred 3-18 months after SRS (median 7.2 months). For 99 ARE cases managed without surgery or bevacizumab, the probabilities of improvement observed on imaging were 40%, 57%, and 76% at 6, 12, and 18 months after onset of ARE. The most important risk factors for ARE included prior SRS to the same lesion (with 20% 1-year risk of symptomatic ARE vs 3%, 4%, and 8% for no prior treatment, prior whole brain radiotherapy [WBRT], or concurrent WBRT) and any of these volume parameters: target, prescription isodose, 12-Gy, or 10-Gy volume. Excluding lesions treated with repeat SRS, the 1-year probabilities of ARE were 2.1 cm, target volume > 1.2 cm(3), prescription isodose volume > 1.8 cm(3

  20. Imaging-therapy computed tomography with quasi-monochromatic X-rays

    International Nuclear Information System (INIS)

    Jost, Gregor; Golfier, Sven; Lawaczeck, Ruediger; Weinmann, Hanns-Joachim; Gerlach, Martin; Cibik, Levent; Krumrey, Michael; Fratzscher, Daniel; Rabe, Johannis; Arkadiev, Vladimir; Haschke, Michael; Langhoff, Norbert; Wedell, Reiner

    2008-01-01

    Introduction: Computed tomography (CT) is a widespread and highly precise technique working in the energy range around 50-100 keV. For radiotherapy, however, the MeV energy range enables a better dose distribution. This gap between diagnosis and therapy can be overcome by the use of a modified CT machine in combination with heavy elements targeted to the tumour and used as photoelectric radiation enhancer. Materials and methods: The experimental setup consists of an X-ray optical module mounted at the exit of the X-ray tube of a clinical CT. The module converts the standard fan-shaped beam into a high intensity, monochromatized and focused beam. The radiation was characterized using an energy-dispersive detection system calibrated by synchrotron radiation and gel dosimetry. The photoelectric radiation enhancement for different elements was calculated and experimentally verified. Results: The X-ray optical module filters selectively the energy of the tungsten Kα-emission line (59.3 keV) with a full width at half maximum (FWHM) of 5 keV and focused the radiation onto a focal spot which coincides with the isocentre of the gantry. This results in a steep dose gradient at the centre of rotation qualified for locoregional radiation therapy. The photon energy of the quasi-monochromatic radiation agrees with the energy range of maximal photoelectric dose enhancement for gadolinium and iodine. Conclusion: An additional X-ray optical module optimized for targeted therapy and photoelectric dose enhancement allows the combination of diagnosis and radiotherapy on a clinical CT

  1. Imaging-therapy computed tomography with quasi-monochromatic X-rays.

    Science.gov (United States)

    Jost, Gregor; Golfier, Sven; Lawaczeck, Ruediger; Weinmann, Hanns-Joachim; Gerlach, Martin; Cibik, Levent; Krumrey, Michael; Fratzscher, Daniel; Rabe, Johannis; Arkadiev, Vladimir; Haschke, Michael; Langhoff, Norbert; Wedell, Reiner; Luedemann, Lutz; Wust, Peter; Pietsch, Hubertus

    2008-12-01

    Computed tomography (CT) is a widespread and highly precise technique working in the energy range around 50-100 keV. For radiotherapy, however, the MeV energy range enables a better dose distribution. This gap between diagnosis and therapy can be overcome by the use of a modified CT machine in combination with heavy elements targeted to the tumour and used as photoelectric radiation enhancer. The experimental setup consists of an X-ray optical module mounted at the exit of the X-ray tube of a clinical CT. The module converts the standard fan-shaped beam into a high intensity, monochromatized and focused beam. The radiation was characterized using an energy-dispersive detection system calibrated by synchrotron radiation and gel dosimetry. The photoelectric radiation enhancement for different elements was calculated and experimentally verified. The X-ray optical module filters selectively the energy of the tungsten K alpha-emission line (59.3 keV) with a full width at half maximum (FWHM) of 5 keV and focused the radiation onto a focal spot which coincides with the isocentre of the gantry. This results in a steep dose gradient at the centre of rotation qualified for locoregional radiation therapy. The photon energy of the quasi-monochromatic radiation agrees with the energy range of maximal photoelectric dose enhancement for gadolinium and iodine. An additional X-ray optical module optimized for targeted therapy and photoelectric dose enhancement allows the combination of diagnosis and radiotherapy on a clinical CT.

  2. Imaging-therapy computed tomography with quasi-monochromatic X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Jost, Gregor [Bayer Schering Pharma AG, Contrast Media Research, Muellerstrasse 178, 13353 Berlin (Germany)], E-mail: gregor.jost@bayerhealthcare.com; Golfier, Sven [Bayer Schering Pharma AG, Contrast Media Research, Muellerstrasse 178, 13353 Berlin (Germany)], E-mail: sven.golfier@bayerhealthcare.com; Lawaczeck, Ruediger [Bayer Schering Pharma AG, Contrast Media Research, Muellerstrasse 178, 13353 Berlin (Germany)], E-mail: ruediger.lawaczeck@bayerhealthcare.com; Weinmann, Hanns-Joachim [Bayer Schering Pharma AG, Contrast Media Research, Muellerstrasse 178, 13353 Berlin (Germany)], E-mail: hanns-joachim.weinmann@bayerhealthcare.com; Gerlach, Martin [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany)], E-mail: martin.gerlach@ptb.de; Cibik, Levent [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany)], E-mail: levent.cibik@ptb.de; Krumrey, Michael [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany)], E-mail: michael.krumrey@ptb.de; Fratzscher, Daniel [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Fratzscher@ifg-adlershof.de; Rabe, Johannis [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Rabe@ifg-adlershof.de; Arkadiev, Vladimir [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Arkadiev@ifg-adlershof.de; Haschke, Michael [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Haschke@ifg-adlershof.de; Langhoff, Norbert [Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: Langhoff@ifg-adlershof.de; Wedell, Reiner [Institut fuer angewandte Photonik e.V., Rudower Chaussee 29/31, 12489 Berlin (Germany)], E-mail: wedell-iap@ifg-adlershof.de (and others)

    2008-12-15

    Introduction: Computed tomography (CT) is a widespread and highly precise technique working in the energy range around 50-100 keV. For radiotherapy, however, the MeV energy range enables a better dose distribution. This gap between diagnosis and therapy can be overcome by the use of a modified CT machine in combination with heavy elements targeted to the tumour and used as photoelectric radiation enhancer. Materials and methods: The experimental setup consists of an X-ray optical module mounted at the exit of the X-ray tube of a clinical CT. The module converts the standard fan-shaped beam into a high intensity, monochromatized and focused beam. The radiation was characterized using an energy-dispersive detection system calibrated by synchrotron radiation and gel dosimetry. The photoelectric radiation enhancement for different elements was calculated and experimentally verified. Results: The X-ray optical module filters selectively the energy of the tungsten K{alpha}-emission line (59.3 keV) with a full width at half maximum (FWHM) of 5 keV and focused the radiation onto a focal spot which coincides with the isocentre of the gantry. This results in a steep dose gradient at the centre of rotation qualified for locoregional radiation therapy. The photon energy of the quasi-monochromatic radiation agrees with the energy range of maximal photoelectric dose enhancement for gadolinium and iodine. Conclusion: An additional X-ray optical module optimized for targeted therapy and photoelectric dose enhancement allows the combination of diagnosis and radiotherapy on a clinical CT.

  3. Stress measurements by multi-reflection grazing-incidence X-ray diffraction method (MGIXD) using different radiation wavelengths and different incident angles

    International Nuclear Information System (INIS)

    Marciszko, Marianna; Baczmański, Andrzej; Braham, Chedly; Wróbel, Mirosław; Wroński, Sebastian; Cios, Grzegorz

    2017-01-01

    The presented study introduces the development of the multi-reflection grazing-incidence X-ray diffraction method (MGIXD) for residual stress determination. The proposed new methodology is aimed at obtaining more reliable experimental data and increasing the depth of non-destructive stress determination below the sample surface. To verify proposed method measurements were performed on a classical X-ray diffractometer (Cu Kα radiation) and using synchrotron radiation (three different wavelengths: λ = 1.2527 Å, λ = 1.5419 Å and λ = 1.7512 Å). The Al2017 alloy subjected to three different surface treatments was investigated in this study. The obtained results showed that the proposed development of MGIXD method, in which not only different incident angles but also different wavelengths of X-ray are used, can be successfully applied for residual stress determination, especially when stress gradients are present in the sample.

  4. Monochromatic and identifiable photons used in photonuclear research

    International Nuclear Information System (INIS)

    Beil, Hans; Bergere, Roland.

    1980-07-01

    A general overview is given of the most common experimental procedures for the production and utilisation of monochromatic and (or) identifiable photon probes actually operational in 1979. Their basic characteristics, merits and drawbacks, together with their respective major domains of experimental physics to which they are usually applied, are also investigated. Methods for producing such monochromatic and (or) identifiable photon probes, with a continuously variable energy from a few MeV up till about 180 GeV, are treated in some detail. Some of the most promising future trends in the ulterior development of such electromagnetic probes are also mentioned

  5. MO-G-BRE-09: Validating FMEA Against Incident Learning Data: A Study in Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Yang, F; Cao, N; Young, L; Howard, J; Sponseller, P; Logan, W; Arbuckle, T; Korssjoen, T; Meyer, J; Ford, E

    2014-01-01

    Purpose: Though FMEA (Failure Mode and Effects Analysis) is becoming more widely adopted for risk assessment in radiation therapy, to our knowledge it has never been validated against actual incident learning data. The objective of this study was to perform an FMEA analysis of an SBRT (Stereotactic Body Radiation Therapy) treatment planning process and validate this against data recorded within an incident learning system. Methods: FMEA on the SBRT treatment planning process was carried out by a multidisciplinary group including radiation oncologists, medical physicists, and dosimetrists. Potential failure modes were identified through a systematic review of the workflow process. Failure modes were rated for severity, occurrence, and detectability on a scale of 1 to 10 and RPN (Risk Priority Number) was computed. Failure modes were then compared with historical reports identified as relevant to SBRT planning within a departmental incident learning system that had been active for two years. Differences were identified. Results: FMEA identified 63 failure modes. RPN values for the top 25% of failure modes ranged from 60 to 336. Analysis of the incident learning database identified 33 reported near-miss events related to SBRT planning. FMEA failed to anticipate 13 of these events, among which 3 were registered with severity ratings of severe or critical in the incident learning system. Combining both methods yielded a total of 76 failure modes, and when scored for RPN the 13 events missed by FMEA ranked within the middle half of all failure modes. Conclusion: FMEA, though valuable, is subject to certain limitations, among them the limited ability to anticipate all potential errors for a given process. This FMEA exercise failed to identify a significant number of possible errors (17%). Integration of FMEA with retrospective incident data may be able to render an improved overview of risks within a process

  6. Pilot Study for the Creation of a European Union Radiation Accident and Incident Data Exchange System (EURAIDE)

    International Nuclear Information System (INIS)

    Stewart, J.E.; Lefaure, C; Czarwinski, R.

    2004-01-01

    This study has had the objective of evaluating the feasibility of: (i) facilitating the establishment of national radiation accident and incident databases where there are none and to encourage the compatibility of such databases, (ii) establishing a European network to exchange radiological protection feedback from accidents and incidents, (iii) establishing summary reports of relevant accidents and incidents with the aim of identifying lessons to be learned, so that they can be used in radiation protection training programs, and (iv) upgrading the radiological safety in the countries applying to join the EU, by integrating them into the above efficient feedback exchange system. This report details the first stage of the project, which was to review the status of existing (or proposed) national mechanisms for collating data on radiation incidents. The objectives of this initial review were to: i) obtain detailed information regarding the means of capturing and collating data, the format of established or proposed data systems and accessibility of the final data, ii) to use this information to consider how a European platform to gather relevant data/accident reports might be established., and iii) to consider how the various elements of national data systems might be harmonised in order to facilitate the presentation and distribution of lessons learned. It was considered that the key aspects that would need to be addressed in order to determine the feasibility of a European wide data exchange mechanism were: - the criteria used for the classification and categorisation of incidents, - criteria for the selection of incidents from national data systems for inclusion in a European-wide system, - the implication of possible language problems. In order to illicit the required information a detailed questionnaire was sent to a total of 31 countries, being existing European Member States, applicant or associated countries. A full list of the countries and institutions

  7. Vegetative and reproductive plasticity of broccoli at three levels of incident photosynthetically active radiation

    International Nuclear Information System (INIS)

    Francescangeli, N.; Martí, H.R.; Sangiacomo, M.A.

    2007-01-01

    To study the effects of shading on the growth, development, dry matter partitioning, and plant architecture of broccoli, ‘Legacy’ hybrid plants were grown in pots in a greenhouse under black shading meshes to generate different levels of photosynthetically active radiation (PAR). The average incident PAR was 23 mol PPF m –2 d –1 under control conditions, 15.2 under a 35% mesh, and 6.7 under a 70% mesh. The air temperature was within the range 15-22°C. As shading increased so did the duration of the growth cycle and the leaf area (LA). Shading did not affect the number of leaves, although the upper ones were more erect. The stem length and the accumulated intercepted PAR (IPAR) were negatively related. Inflorescence diameter and commercial fresh weight decreased only with the 70% mesh. Shading did not affect stem dry weight (DW) but altered dry matter allocation in the root and spear. The DW of the leaves maintained an average 45.7% of the total DW despite the greater LA developed under shade. The net assimilation rate diminished with the reduction of IPAR, and the LA increased; the plant relative growth rate was therefore practically constant. With increased shading, the leaves and the stem became the dominant photosynthate sinks. The commercial fresh weight achieved with 15.2 mol photosynthetic photon flux (PPF) m –2 d –1 was equivalent to that obtained with 23 mol PPF m –2 d –1 , but the cycle was extended for 4.5 days. With 6.7 mol PPF m –2 d –1 , yield diminished because of the lower DW produced in a cycle extended by 15 days, and because more dry matter was allocated to the stem than to the spear. Based on these results, broccoli could be considered a shade-tolerant plant. (author) [es

  8. Incidence of primary hypothyroidism in patients exposed to therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland

    Directory of Open Access Journals (Sweden)

    B A Laway

    2012-01-01

    Full Text Available Introduction: Hypothyroidism is a known consequence of external-beam radiotherapy to the neck encompassing a part or whole of the thyroid gland. In this non-randomized prospective study, we have tried to evaluate the response of the thyroid gland to radiation by assessing thyroid function before irradiation and at regular intervals after irradiation. Aims and Objectives: The aim of this study were to assess in the cancer patients, who were exposed to the therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland: the incidence of primary hypothyroidism, the time required to become hypothyroid, any relation between the total dose for the development of hypothyroidism, and whether there are any patient or treatment-related factors that are predictive for the development of hypothyroidism, including the use of concurrent chemotherapy. Materials and Methods: This non-randomized, prospective study was conducted for a period of 2 years in which thyroid function was assessed in 59 patients (cases of head and neck cancer, breast cancer, lymphoma patients and other malignancies, who had received radiotherapy to the neck region. 59 euthyroid healthy patients (controls were also taken, who had not received the neck irradiation. These patients/controls were assessed periodically for 2 years. Results: The incidence of hypothyroidism after external beam radiation therapy (EBRT to neck where radiation portals include part or whole of the thyroid gland was 16.94%, seven cases had subclinical hypothyroidism (11.86% and three cases had clinical hypothyroidism (5.08%. Mean time for development of hypothyroidism was 4.5 months. There was no effect of age, gender, primary tumor site, radiation dose and chemotherapy, whether neoadjuvant or concurrent with the development of hypothyroidism. Conclusion: In summary, we found that thyroid dysfunction is a prevalent, yet easily treatable source of morbidity in patients

  9. High efficiency quasi-monochromatic infrared emitter

    Energy Technology Data Exchange (ETDEWEB)

    Brucoli, Giovanni; Besbes, Mondher; Benisty, Henri, E-mail: henri.benisty@institutoptique.fr; Greffet, Jean-Jacques [Laboratoire Charles Fabry, UMR 8501, Institut d’Optique, CNRS, Université Paris-Sud 11, 2, Avenue Augustin Fresnel, 91127 Palaiseau Cedex (France); Bouchon, Patrick; Haïdar, Riad [Office National d’Études et de Recherches Aérospatiales, Chemin de la Hunière, 91761 Palaiseau (France)

    2014-02-24

    Incandescent radiation sources are widely used as mid-infrared emitters owing to the lack of alternative for compact and low cost sources. A drawback of miniature hot systems such as membranes is their low efficiency, e.g., for battery powered systems. For targeted narrow-band applications such as gas spectroscopy, the efficiency is even lower. In this paper, we introduce design rules valid for very generic membranes demonstrating that their energy efficiency for use as incandescent infrared sources can be increased by two orders of magnitude.

  10. Suppressing effect of low-dose ionizing radiation on incidence of type I diabetes of NOD mice

    International Nuclear Information System (INIS)

    Nomura, T.; Makino, N.; Oda, T.; Sakai, K.

    2002-01-01

    In the present study we examined the effects of 0.5 Gy of ionizing radiation, given acutely or chronically, on the incidence of type I diabetes in non-obese diabetic mice was examined. NOD mice are characterized by a progressive loss of insulin-producing cells in the pancreas by autoimmune mechanisms. The results suggest that the suppressive effects on the onset of he diabetes by the low dose irradiation are explain by the induction of the antioxidative activity

  11. L-shell radiative transition rates by selective synchrotron ionization

    International Nuclear Information System (INIS)

    Bonetto, R D; Carreras, A C; Trincavelli, J; Castellano, G

    2004-01-01

    Relative L-shell radiative transition rates were obtained for a number of decays in Gd, Dy, Er, Yb, Hf, Ta and Re by means of a method for refining atomic and experimental parameters involved in the spectral analysis of x-ray irradiated samples. For this purpose, pure samples were bombarded with monochromatic synchrotron radiation tuning the incident x-ray energy in order to allow selective ionization of the different atomic shells. The results presented are compared to experimental and theoretical values published by other authors. A good general agreement was found and some particular discrepancies are discussed

  12. Observed linkages between the northern annular mode/North Atlantic Oscillation, cloud incidence, and cloud radiative forcing

    Science.gov (United States)

    Li, Ying; Thompson, David W. J.; Huang, Yi; Zhang, Minghong

    2014-03-01

    The signature of the northern annular mode/North Atlantic Oscillation (NAM/NAO) in the vertical and horizontal distribution of tropospheric cloudiness is investigated in CloudSat and CALIPSO data from June 2006 to April 2011. During the Northern Hemisphere winter, the positive polarity of the NAM/NAO is marked by increases in zonally averaged cloud incidence north of ~60°N, decreases between ~25 and 50°N, and increases in the subtropics. The tripolar-like anomalies in cloud incidence associated with the NAM/NAO are largest over the North Atlantic Ocean basin/Middle East and are physically consistent with the NAM/NAO-related anomalies in vertical motion. Importantly, the NAM/NAO-related anomalies in tropospheric cloud incidence lead to significant top of atmosphere cloud radiative forcing anomalies that are comparable in amplitude to those associated with the NAM/NAO-related temperature anomalies. The results provide observational evidence that the most prominent pattern of Northern Hemisphere climate variability is significantly linked to variations in cloud radiative forcing. Implications for two-way feedback between extratropical dynamics and cloud radiative forcing are discussed.

  13. Incidence of and factors related to late complications in conformal and conventional radiation treatment of cancer of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Schultheiss, Timothy E; Hanks, Gerald E; Hunt, Margie A; Lee, W Robert

    1995-06-15

    Purpose: The fundament hypothesis of conformal radiation therapy is that tumor control can be increased by using conformal treatment techniques that allow a higher tumor dose while maintaining an acceptable level of complications. To test this hypothesis, it is necessary first to estimate the incidence of morbidity for both standard and conformal fields. In this study, we examine factors that influence the incidence of late Grade 3 and 4 morbidity in patients treated with conformal and standard radiation treatment for prostate cancer. Methods and Materials: Six hundred sixteen consecutive patients treated with conformal or standard techniques between 1986 and 1994 to doses greater than 65 Gy and with more than 3 months follow-up were analyzed. No patients treated with prostatectomies were included in the analysis. The conformal technique includes special immobilization by a cast, careful identification of the target volume in three dimensions, localization of the inferior border of the prostate using a retrograde urethrogram, and individually shaped portals that conform to the Planning Target Volume (PTV). Multivariate analysis using a proportional hazards model compares differences in the incidence of Radiation Therapy Oncology Group/European Organization for Research and Center Treatment (RTOG/EORTC) Grade 3 and 4 late gastrointestinal (GI) and genitourinary (GU) morbidity by technique, T-stage, grade, age, hormonal treatment, irradiated volume, dose, and comorbid conditions. Grade 3 rectal bleeding was defined as requiring three or more cautery procedures. Results: The overall actuarial incidence of genitourinary (GU) toxicities at 5 years was 3.4%, with the crude incidence being six cases in 616 patients satisfying the selection criteria; for gastrointestinal (GI) toxicities, the overall actuarial incidence was 2.7%, with the crude incidence being 13 cases out of 616 patients. The average time to complication for our patients was 12.8 months for GI toxicity and

  14. Ultraviolet Radiation Exposure and the Incidence of Oral, Pharyngeal and Cervical Cancer and Melanoma: An Analysis of the SEER Data.

    Science.gov (United States)

    Adams, Spencer; Lin, Jie; Brown, Derek; Shriver, Craig D; Zhu, Kangmin

    2016-01-01

    Based on the hypothesis that ultraviolet radiation (UVR) exposure can cause DNA damage that may activate dormant viruses such as human papilloma virus, a recent ecological study, which estimated state-level UVR exposure, reported positive correlations between annual UVR exposure and the incidence of oral, pharyngeal, and cervical cancer in 16 U.S. states using the International Agency for Research on Cancer (IARC) data. The purpose of the current study was to further investigate whether the annual UVR level, estimated on a county level, is associated with incidence rates of such cancers using the National Cancer Institute's Surveillance, Epidemiology, and End Results (SEER) 18 data. If UVR exposure is associated with incidence of these cancer types, we would expect to see a similar or stronger association with melanoma because UVR exposure is a well-demonstrated risk factor for this disease. Thus, we also included melanoma in the study. The study subjects were White and Black individuals with oral, pharyngeal, cervical cancer or melanoma diagnosed between 1973 and 2011 from the SEER 18 data. UVR was estimated at the county level and grouped into high-, medium- and low-exposure levels. Age-adjusted incidence rates of cancer were calculated and compared among the UVR exposure groups. The comparisons were also stratified by sex and race. There was an inverse association between UVR exposure and incidence of oral, pharyngeal, and cervical cancer. The inverse association was also observed for melanoma. When stratified by race and sex, the inverse associations remained except for melanoma among Blacks. In contrast to a previous study, our study found that there were inverse associations between UVR exposure and the incidence of oral, pharyngeal, and cervical cancer, as well as of melanoma. Our findings are in agreement with several other published studies reporting no positive correlation between UVR exposure and the incidence rates of oral, pharyngeal, and cervical

  15. The incidence of breast cancer following mantle field radiation therapy as a function of dose and technique

    International Nuclear Information System (INIS)

    Tinger, Alfred; Wasserman, Todd H.; Klein, Eric E.; Miller, Elizabeth A.; Roberts, Tracy; Piephoff, James V.; Kucik, Nancy A.

    1997-01-01

    Purpose: There is an increased incidence of breast cancer following mantle field radiation therapy for Hodgkin's disease (HD). We reviewed the experience at the Mallinckrodt Institute of Radiology (MIR) for radiation factors related to the development of breast cancer after mantle field radiation therapy for HD. Methods: The radiation therapy records of 152 women treated with mantle field irradiation for HD at MIR between 1966-1985 were reviewed for the development of breast cancer and treatment-related factors. All patients had a minimum of 5 years of follow-up. The treatment era (1966-1974 vs. 1975-1985), stage of HD, mediastinal dose, axillary dose, maximum dose from the anterior field (anterior d max dose), the anterior-posterior:posterior-anterior (AP:PA) ratio, age at the time of treatment, length of follow-up, and history of splenectomy were analyzed as possible contributing factors for the development of breast cancer. The observed number of breast cancers was compared to the expected number based on age-adjusted incidences from the Connecticut Tumor Registry. Results: Ten breast cancers occurred in the population. Eight involved an upper outer quadrant. In a multivariate analysis, the development of breast cancer was significantly associated with axillary dose. Patients in the early treatment era were at an increased risk for the development of breast cancer due to high anterior d max and breast doses from weighting the fields anteriorly on a low energy linear accelerator. The use of current radiation therapy techniques was not related to an increased risk of breast cancer with a median follow-up of 13 years. Conclusions: A high dose to the axilla and the anterior d max point is significantly associated with the development of breast cancer after mantle field irradiation for HD. Efforts to protect the breast from high doses will likely lessen the increased risk of breast cancer in women treated with radiation therapy for HD

  16. Pathophysiological effects of radiation on atherosclerosis development and progression, and the incidence of cardiovascular complications

    International Nuclear Information System (INIS)

    Basavaraju, Sekhara Rao; Easterly, Clay E.

    2002-01-01

    Radiation therapy while important in the management of several diseases, is implicated in the causation of atherosclerosis and other cardiovascular complications. Cancer and atherosclerosis go through the same stages of initiation, promotion, and complication, beginning with a mutation in a single cell. Clinical observations before the 1960s lead to the belief that the heart is relatively resistant to the doses of radiation used in radiotherapy. Subsequently, it was discovered that the heart is sensitive to radiation and many cardiac structures may be damaged by radiation exposure. A significantly higher risk of death due to ischemic heart disease has been reported for patients treated with radiation for Hodgkin's disease and breast cancer. Certain cytokines and growth factors, such as TGF-β1 and IL-1 β, may stimulate radiation-induced endothelial proliferation, fibroblast proliferation, collagen deposition, and fibrosis leading to advanced lesions of atherosclerosis. The treatment for radiation-induced ischemic heart disease includes conventional pharmacological therapy, balloon angioplasty, and bypass surgery. Endovascular irradiation has been shown to be effective in reducing restenosis-like response to balloon-catheter injury in animal models. Caution must be exercised when radiation therapy is combined with doxorubicin because there appears to be a synergistic toxic effect on the myocardium. Damage to endothelial cells is a central event in the pathogenesis of damage to the coronary arteries. Certain growth factors that interfere with the apoptotic pathway may provide new therapeutic strategies for reducing the risk of radiation-induced damage to the heart. Exposure to low level occupational or environmental radiation appears to pose no undue risk of atherosclerosis development or cardiovascular mortality. But, other radiation-induced processes such as the bystander effects, abscopal effects, hormesis, and individual variations in radiosensitivity may be

  17. Thermal radiation heat transfer in participating media by finite volume discretization using collimated beam incidence

    Science.gov (United States)

    Harijishnu, R.; Jayakumar, J. S.

    2017-09-01

    The main objective of this paper is to study the heat transfer rate of thermal radiation in participating media. For that, a generated collimated beam has been passed through a two dimensional slab model of flint glass with a refractive index 2. Both Polar and azimuthal angle have been varied to generate such a beam. The Temperature of the slab and Snells law has been validated by Radiation Transfer Equation (RTE) in OpenFOAM (Open Field Operation and Manipulation), a CFD software which is the major computational tool used in Industry and research applications where the source code is modified in which radiation heat transfer equation is added to the case and different radiation heat transfer models are utilized. This work concentrates on the numerical strategies involving both transparent and participating media. Since Radiation Transfer Equation (RTE) is difficult to solve, the purpose of this paper is to use existing solver buoyantSimlpeFoam to solve radiation model in the participating media by compiling the source code to obtain the heat transfer rate inside the slab by varying the Intensity of radiation. The Finite Volume Method (FVM) is applied to solve the Radiation Transfer Equation (RTE) governing the above said physical phenomena.

  18. Combined effects of radiation and other agents on the stomach cancer incidence among Mayak Atomic Plant workers

    Energy Technology Data Exchange (ETDEWEB)

    Zhuntova, G.V.; Tokarskaya, Z.B.; Belyaeva, Z.D. [Branch No 1 of State Research Center of Public Health Ministry of the Russian Federation, Ozyorsk (Russian Federation). Biophysics Inst.; Rovny, S.I.; Sirchikov, V.A.

    2000-05-01

    The gravity of a problem of the combined action of radiation and other factors again was confirmed sessions UNSCEAR in May, 1998. It especially is important at study of cancer diseases in connection with the polyetiology and multistage of them development. The estimation of radiation, medico-biological factors and condition of life in occurrence of a stomach cancer among Mayak personnel was specified by case-cohort research. For a quota 503 men (157 cases of a stomach cancer, 346 men of the healthy personnel) attributive risk of the radiation factors was 8.8%, medico-biological - 57,2% (from them by greatest was influence chronic gastritis with secreting insufficiency - 35.4%), tobacco consumption - 31,6%. At an estimation of risk of a stomach cancer depending on external {gamma}-irradiation best fitting was received at use of square-law model. The excess relative risk was 0,27 Gr{sup -2} (F=44,5; P=0,007). For {sup 239}Pu incorporation was not revealed of distinct connection with stomach cancer incidences. Interaction of the radiation and non-radiation factors also was appreciated. The interaction of gastritis with external {gamma}-irradiation or {sup 239}Pu was multiplicate. The interaction of smoking with {gamma}-irradiation or {sup 239}Pu incorporation was multiplicate also. The distribution histological types of a stomach cancer among the workers of Mayak plant differed in comparison with not working. Among the workers the increase poorly differentiated adenocarcinoma was observed. (author)

  19. Combined effects of radiation and other agents on the stomach cancer incidence among Mayak Atomic Plant workers

    International Nuclear Information System (INIS)

    Zhuntova, G.V.; Tokarskaya, Z.B.; Belyaeva, Z.D.; Rovny, S.I.; Sirchikov, V.A.

    2000-01-01

    The gravity of a problem of the combined action of radiation and other factors again was confirmed sessions UNSCEAR in May, 1998. It especially is important at study of cancer diseases in connection with the polyetiology and multistage of them development. The estimation of radiation, medico-biological factors and condition of life in occurrence of a stomach cancer among Mayak personnel was specified by case-cohort research. For a quota 503 men (157 cases of a stomach cancer, 346 men of the healthy personnel) attributive risk of the radiation factors was 8.8%, medico-biological - 57,2% (from them by greatest was influence chronic gastritis with secreting insufficiency - 35.4%), tobacco consumption - 31,6%. At an estimation of risk of a stomach cancer depending on external γ-irradiation best fitting was received at use of square-law model. The excess relative risk was 0,27 Gr -2 (F=44,5; P=0,007). For 239 Pu incorporation was not revealed of distinct connection with stomach cancer incidences. Interaction of the radiation and non-radiation factors also was appreciated. The interaction of gastritis with external γ-irradiation or 239 Pu was multiplicate. The interaction of smoking with γ-irradiation or 239 Pu incorporation was multiplicate also. The distribution histological types of a stomach cancer among the workers of Mayak plant differed in comparison with not working. Among the workers the increase poorly differentiated adenocarcinoma was observed. (author)

  20. Higher order monochromatic aberrations of the human infant eye

    OpenAIRE

    Wang, Jingyun; Candy, T. Rowan

    2005-01-01

    The monochromatic optical aberrations of the eye degrade retinal image quality. Any significant aberrations during postnatal development could contribute to infants’ immature visual performance and provide signals for the control of eye growth. Aberrations of human infant eyes from 5 to 7 weeks old were compared with those of adult subjects using a model of an adultlike infant eye that accounted for differences in both eye and pupil size. Data were collected using the COAS Shack-Hartmann wave...

  1. Monte Carlo mixture model of lifetime cancer incidence risk from radiation exposure on shuttle and international space station

    International Nuclear Information System (INIS)

    Peterson, L.E.; Cucinotta, F.A.

    1999-01-01

    Estimating uncertainty in lifetime cancer risk for human exposure to space radiation is a unique challenge. Conventional risk assessment with low-linear-energy-transfer (LET)-based risk from Japanese atomic bomb survivor studies may be inappropriate for relativistic protons and nuclei in space due to track structure effects. This paper develops a Monte Carlo mixture model (MCMM) for transferring additive, National Institutes of Health multiplicative, and multiplicative excess cancer incidence risks based on Japanese atomic bomb survivor data to determine excess incidence risk for various US astronaut exposure profiles. The MCMM serves as an anchor point for future risk projection methods involving biophysical models of DNA damage from space radiation. Lifetime incidence risks of radiation-induced cancer for the MCMM based on low-LET Japanese data for nonleukemia (all cancers except leukemia) were 2.77 (90% confidence limit, 0.75-11.34) for males exposed to 1 Sv at age 45 and 2.20 (90% confidence limit, 0.59-10.12) for males exposed at age 55. For females, mixture model risks for nonleukemia exposed separately to 1 Sv at ages of 45 and 55 were 2.98 (90% confidence limit, 0.90-11.70) and 2.44 (90% confidence limit, 0.70-10.30), respectively. Risks for high-LET 200 MeV protons (LET=0.45 keV/μm), 1 MeV α-particles (LET=100 keV/μm), and 600 MeV iron particles (LET=180 keV/μm) were scored on a per particle basis by determining the particle fluence required for an average of one particle per cell nucleus of area 100 μm 2 . Lifetime risk per proton was 2.68x10 -2 % (90% confidence limit, 0.79x10 -3 %-0.514x10 -2 %). For α-particles, lifetime risk was 14.2% (90% confidence limit, 2.5%-31.2%). Conversely, lifetime risk per iron particle was 23.7% (90% confidence limit, 4.5%-53.0%). Uncertainty in the DDREF for high-LET particles may be less than that for low-LET radiation because typically there is very little dose-rate dependence. Probability density functions for

  2. Photofission of NAT Pt by monochromatic and polarized photons in the quasi-deuteron region

    International Nuclear Information System (INIS)

    Paiva, Eduardo de.

    1992-01-01

    The measurement of the Nat Pt photofission yield at 69 MeV of effective average energy of the incident photon is made using a polarized and monochromatic photon beam from the LADON system of the National Laboratory of Frascati, Italy, produced by inverse Compton scattering of laser light by high energy electrons of the ADONE Accelerator and using as fission track solid detector the Makrofol, being the developing made by usual procedure. The experimental value of the nuclear fissionability is compared to a theoretical value obtained following a model at two stages: in the first, the photon energy is absorbed by a neutron-proton pair inducing to the nucleus excitation, and in the second the nucleus de-excites due to the competition between nucleon evaporation and fission. The effect of fast nucleon emission during the first stage and the successive evaporation of neutrons in the second stage are considered. 40 refs, 12 figs, 9 tabs

  3. New optical scheme for differential measurements of diffraction reflection intensity on X-radiation sliding incidence

    International Nuclear Information System (INIS)

    Golovin, A.L.; Mas', E.T.

    1989-01-01

    An X-ray optical scheme for differential measurements of X-ray diffraction under sliding incidence conditions is proposed and an attachment design realizng this scheme, using standard equipment, is described. The main feature of the scheme is the following: collimation according to the Bragg angle is carried out for the reflected beam rather than the incident one. Goniometers can be used from DRON, TRS, GS-5 and other spectrometers. The goniometer head carrying the sample is standard, it is a part of the DRON, TRS and DTS. The crystal analyzer is fixed on the attachment. The angular position of the crystal monochromator is controlled by an inductive sensor. The experimental differential curves of X-ray diffraction under conditions of sliding incidence, taken for a silicon crystal having the 111 orientation, are given as well

  4. Factors influencing incidence of acute grade 2 morbidity in conformal and standard radiation treatment of prostate cancer

    International Nuclear Information System (INIS)

    Hanks, Gerald E.; Schultheiss, Timothy E.; Hunt, Margie A.; Epstein, Barry

    1995-01-01

    Purpose: The fundament hypothesis of conformal radiation therapy is that tumor control can be increased by using conformal treatment techniques that allow a higher tumor dose while maintaining an acceptable level of complications. To test this hypothesis, it is necessary first to estimate the incidence of morbidity for both standard and conformal fields. In this study, we examine factors that influence the incidence of acute grade 2 morbidity in patients treated with conformal and standard radiation treatment for prostate cancer. Methods and Materials: Two hundred and forty-seven consecutive patients treated with conformal technique are combined with and compared to 162 consecutive patients treated with standard techniques. The conformal technique includes special immobilization by a cast, careful identification of the target volume in three dimensions, localization of the inferior border of the prostate using the retrograde urethrogram, and individually shaped portals that conform to the Planning Target Volume (PTV). Univariate analysis compares differences in the incidence of RTOG-EORTC grade two acute morbidity by technique, T stage, age, irradiated volume, and dose. Multivariate logistic regression includes these same variables. Results: In nearly all categories, the conformal treatment group experienced significantly fewer acute grade 2 complications than the standard treatment group. Only volume (prostate ± whole pelvis) and technique (conformal vs. standard) were significantly related to incidence of morbidity on multivariate analysis. When dose is treated as a continuous variable (rather than being dichotomized into two levels), a trend is observed on multivariate analysis, but it does not reach significant levels. The incidence of acute grade 2 morbidity in patients 65 years or older is significantly reduced by use of the conformal technique. Conclusion: The conformal technique is associated with fewer grade 2 acute toxicities for all patients. This

  5. Effect of γ-radiation on the incidence of plant tumors (to the problem of carcinogenesis)

    International Nuclear Information System (INIS)

    Kuzin, A.M.; Yurov, S.S.; Vagabova, M.Eh.; Shchelkaeva, N.V.

    1986-01-01

    In experiments on two plant species: of Kalanchoe diagremontiana and potato (Solanum tuberosum) it was shown that γ-irradiation of the plant tissues, before infecting with Ti-plasmide Agrobacterium tumefaciens C-58, with doses stimulating the development of the plants markedly increases the incidence of tumors, promotes their growth, and increases the probability of inverse differentiation of tumor cells

  6. Tables extracted from Messel and Crawford for electrons incident on 1 radiation length Pb plates

    International Nuclear Information System (INIS)

    Loos, J.

    1977-01-01

    Tables were extracted from the extensive tables of Messel and Crawford. The numbers given should be good for 1 r.1. Ta plates and may be helpful when looking at showers in these plates. The tables should be largely self-explanatory. An example is given of how to use these tables given a 1000-MeV incident electron

  7. Emergency preparedness incident response and radiation monitoring in Finland. Annual report 1999

    International Nuclear Information System (INIS)

    Ristonmaa, S.

    2000-04-01

    The Radiation and Nuclear Safety Authority (STUK) publishes annually a report about STUK's preparedness measures. The report describes notifications received by STUK's on duty system and further measures carried out after receiving a message. In addition, the emergence exercises STUK participated in during the year are described. The radiation situation in Finland is continuously monitored. STUK is the authority who carries out a wide range of environmental measurements, sampling and sensitive laboratory analyses. The measurement results are presented in the form of tables and graphically. (editor)

  8. Emergency preparedness incident response and radiation monitoring in Finland. Annual report 1998

    International Nuclear Information System (INIS)

    Ristonmaa, S.

    1999-03-01

    The Radiation and Nuclear Safety Authority (STUK) publishes annually a report about STUK's preparedness measures. The report describes notifications received by STUK's on duty system and further measures carried out after receiving a message. In addition, the emergence exercises STUK participated in during the year are described. The radiation situation in Finland is continuously monitored. STUK is the authority who carries out a wide range of environmental measurements, sampling and sensitive laboratory analyses. The measurement results are presented in the form of tables and graphically. (editor)

  9. Radiation factors and smoking interaction at lung cancer incidence for workers at a nuclear enterprise

    International Nuclear Information System (INIS)

    Tokarskaya, Z.B.; Khokhryakov, V.F.; Okladnikova, N.D.; Belyaeva, Z.D.; Zhuntova, G.V.

    1997-01-01

    It was shown on the basis of retrospective investigation of 500 workers at a nuclear enterprise (162 cases of lung cancer, 338 persons as matching control) that the interaction of external gamma-irradiation (> 2.0 Gy) and the body - burden of 239 Pu (> 9.3 kBq) at lung cancer is characterized as the multiplicative effect. Combined influence of smoking and radiation factors dependent on smoking index (SI): it changed from additive up to multiplicative and than to antagonistic with the increase of the smoking effect. The received results could be explained on the basis of a two - mutation model of radiation carcinogenesis

  10. Thyroid cancer incidence in iodine deficient areas exposed to radiation after Chernobyl accident

    International Nuclear Information System (INIS)

    Szybinski, Z.; Mazurek-Przybylik, E.

    1996-01-01

    In two districts of Southern Poland; Krakow and Nowy Sacz (2 million people), standardized thyroid cancer incidence rate IR was evaluated from 1976 to 1992. This area was classified as a moderate iodine deficiency endemic goiter region and belonged to the most contaminated areas in Poland after Chernobyl accident. Recalculated - in terms of real iodine intake-thyroid commitment equivalent dose in the youngest age groups reached 100 mSv. The aim of the study was to evaluate, 6 years after Chernobyl accident, thyroid cancer incidence rate and histotype. Age and sex specific incidence rate in Krakow for male was 0.827 and for female 3.093 and 0.93 and 2.164 for Nowy Sacz respectively. There was no increase of IR in the group of age 0-19 yrs, however in the group over 44 yrs in females in the period of time 1989-1992 significant increase of follicular cancer was observed. In the histotype, the follicular cancerpredominated over the papillary one: 42,9% against 33,6%. Predominance of the follicular cancer is typical for iodine deficient area. Significant increase of the follicular cancer may be due to the increase of iodine deficiency. (author). 14 refs, 1 fig., 5 tabs

  11. Thyroid cancer incidence in iodine deficient areas exposed to radiation after Chernobyl accident

    Energy Technology Data Exchange (ETDEWEB)

    Szybinski, Z; Mazurek-Przybylik, E [Jagiellonian Univ., Cracow (Poland). Dept. of Endocrinology; Pawlega, J [Institute of Oncology, Cracow (Poland)

    1996-08-01

    In two districts of Southern Poland; Krakow and Nowy Sacz (2 million people), standardized thyroid cancer incidence rate IR was evaluated from 1976 to 1992. This area was classified as a moderate iodine deficiency endemic goiter region and belonged to the most contaminated areas in Poland after Chernobyl accident. Recalculated - in terms of real iodine intake-thyroid commitment equivalent dose in the youngest age groups reached 100 mSv. The aim of the study was to evaluate, 6 years after Chernobyl accident, thyroid cancer incidence rate and histotype. Age and sex specific incidence rate in Krakow for male was 0.827 and for female 3.093 and 0.93 and 2.164 for Nowy Sacz respectively. There was no increase of IR in the group of age 0-19 yrs, however in the group over 44 yrs in females in the period of time 1989-1992 significant increase of follicular cancer was observed. In the histotype, the follicular cancerpredominated over the papillary one: 42,9% against 33,6%. Predominance of the follicular cancer is typical for iodine deficient area. Significant increase of the follicular cancer may be due to the increase of iodine deficiency. (author). 14 refs, 1 fig., 5 tabs.

  12. Radiation safety education reduces the incidence of adult fingers on neonatal chest radiographs

    International Nuclear Information System (INIS)

    Sahota, N; Burbridge, B E; Duncan, M D

    2014-01-01

    A previous audit revealed a high frequency of adult fingers visualised on neonatal intensive care unit (NICU) chest radiographs—representing an example of inappropriate occupational radiation exposure. Radiation safety education was provided to staff and we hypothesised that the education would reduce the frequency of adult fingers visualised on NICU chest radiographs. Two cross-sectional samples taken before and after the administration of the education were compared. We examined fingers visualised directly in the beam, fingers in the direct beam but eliminated by technologists editing the image, and fingers under the cones of the portable x-ray machine. There was a 46.2% reduction in fingers directly in the beam, 50.0% reduction in fingers directly in the beam but cropped out, and 68.4% reduction in fingers in the coned area. There was a 57.1% overall reduction in adult fingers visualised, which was statistically significant (Z value − 7.48, P < 0.0001). This study supports radiation safety education in minimising inappropriate occupational radiation exposure. (paper)

  13. Relationship between incident radiation, leaf area and dry-matter yield in wheat

    International Nuclear Information System (INIS)

    Saini, A.D.; Nanda, R.

    1986-01-01

    Light-utilization efficiency was evaluated between 20 and 50 days of crop growth period in 'Kalyansona', 'Sonalika' (semi-dwarf), 'Hindi 62' (tall) varieties of bread-wheat (Triticum aestivum Linn. emend., Fiori and Paol.) and semi-dwarf 'HD 4502' variety of macaroni wheat (T. durum Desf.). In the first model, the relationship between absorbed photosynthetic radiation and crop growth rates showed above-ground dry matter of 2.9 g in 'Sonalika', 2.5 g each in 'Kalyansona' and 'HD 4502' and 1.8 g in 'Hindi 62' were produced for each megajoule of absorbed photosynthetic radiation corresponding to the growth efficiency of 5.1, 4.4 and 3.1% respectively. In the second model of partial regression analysis, the rate of change in dry matter due to mean green area index as well as photosynthetic radiation was low in 'Hindi 62'. However, the dry matter changes due to mean green area index were similar in 'Kalyansona', 'HD4502' and 'Sonalika', but was high due to photosynthetic radiation in 'Sonalika' only. Both models gave similar conclusion

  14. Ionizing radiation increases primary cilia incidence and induces multiciliation in C2C12 myoblasts

    Czech Academy of Sciences Publication Activity Database

    Filipová, A.; Diaz-Garcia, D.; Bezrouk, A.; Čížková, D.; Havelek, R.; Vávrová, J.; Dayanithi, Govindan; Řezáčová, M.

    2015-01-01

    Roč. 39, č. 8 (2015), s. 943-953 ISSN 1065-6995 Institutional support: RVO:68378041 Keywords : cell line * ionizing radiation * multiple cilia * myoblast * primary cilium * serum starvation stress Subject RIV: FP - Other Medical Disciplines Impact factor: 1.663, year: 2015

  15. Measuring Solar Radiation Incident on Earth: Solar Constant-3 (SOLCON-3)

    Science.gov (United States)

    Crommelynck, Dominique; Joukoff, Alexandre; Dewitte, Steven

    2002-01-01

    Life on Earth is possible because the climate conditions on Earth are relatively mild. One element of the climate on Earth, the temperature, is determined by the heat exchanges between the Earth and its surroundings, outer space. The heat exchanges take place in the form of electromagnetic radiation. The Earth gains energy because it absorbs solar radiation, and it loses energy because it emits thermal infrared radiation to cold space. The heat exchanges are in balance: the heat gained by the Earth through solar radiation equals the heat lost through thermal radiation. When the balance is perturbed, a temperature change and hence a climate change of the Earth will occur. One possible perturbation of the balance is the CO2 greenhouse effect: when the amount of CO2 in the atmosphere increases, this will reduce the loss of thermal infrared radiation to cold space. Earth will gain more heat and hence the temperature will rise. Another perturbation of the balance can occur through variation of the amount of energy emitted by the sun. When the sun emits more energy, this will directly cause a rise of temperature on Earth. For a long time scientists believed that the energy emitted by the sun was constant. The 'solar constant' is defined as the amount of solar energy received per unit surface at a distance of one astronomical unit (the average distance of Earth's orbit) from the sun. Accurate measurements of the variations of the solar constant have been made since 1978. From these we know that the solar constant varies approximately with the 11-year solar cycle observed in other solar phenomena, such as the occurrence of sunspots, dark spots that are sometimes visible on the solar surface. When a sunspot occurs on the sun, since the spot is dark, the radiation (light) emitted by the sun drops instantaneously. Oddly, periods of high solar activity, when a lot of sunspot numbers increase, correspond to periods when the average solar constant is high. This indicates that

  16. Contribution of Topography and Incident Solar Radiation to Variation of Soil and Plant Litter at an Area with Heterogeneous Terrain

    Directory of Open Access Journals (Sweden)

    Felipe Cito Nettesheim

    2015-06-01

    Full Text Available Natural processes that determine soil and plant litter properties are controlled by multiple factors. However, little attention has been given to distinguishing the effects of environmental factors from the effects of spatial structure of the area on the distribution of soil and litter properties in tropical ecosystems covering heterogeneous topographies. The aim of this study was to assess patterns of soil and litter variation in a tropical area that intercepts different levels of solar radiation throughout the year since its topography has slopes predominantly facing opposing geographic directions. Soil data (pH, C, N, P, H+Al, Ca, Mg, K, Al, Na, sand, and silt and plant litter data (N, K, Ca, P, and Mg were gathered together with the geographic coordinates (to model the spatial structure of 40 sampling units established at two sites composed of slopes predominantly facing northwest and southeast (20 units each. Soil and litter chemical properties varied more among slopes within similar geographic orientations than between the slopes facing opposing directions. Both the incident solar radiation and the spatial structure of the area were relevant in explaining the patterns detected in variation of soil and plant litter. Individual contributions of incident solar radiation to explain the variation in the properties evaluated suggested that this and other environmental factors may play a particularly relevant role in determining soil and plant litter distribution in tropical areas with heterogeneous topography. Furthermore, this study corroborates that the spatial structure of the area also plays an important role in the distribution of soil and litter within this type of landscape, which appears to be consistent with the action of water movement mechanisms in such areas.

  17. Accidents and incidents with external and/or internal radiation-exposure

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    An individual radiation exposure accident is an unexpected and unintended event which gives rise to an overexposure (external or internal). By overexposure one means all external or internal exposure which could lead to the exceeding of the regulatory norms. Going beyond these limits does not always produce pathological manifestations. The term radiological accident is, in practice, used only when there is an occurrence of some biological or clinical response, or when some therapeutic action is required. A radio-exposure accident can occur: within or from a nuclear power plant or from a center employing ionizing radiation. These are the most frequent; and during the transport of radioactive materials. These are exceptional events. The tanks and containers used in the transport of highly radioactive substances are exhaustively studied for their resistance to accidents, and the conditions of transport determined by very strict national and international regulations. The transport of substances of low radioactivity (labelled molecules, radiopharmaceuticals...) carries only minor risks

  18. Preliminary studies into profiling DNA recovered from a radiation or radioactivity incident

    International Nuclear Information System (INIS)

    Hodgson, A.; Baxter, A.

    2013-01-01

    The examination and profiling of human DNA recovered from a scene of crime is an essential aspect of criminal investigations. However, it is currently not known whether DNA recovered from a scene where an ionising radiation source or radioactive contamination is present can be successfully profiled. The direct examination and analysis of radioactively contaminated DNA has not been widely explored using the current procedures employed by forensic service providers. As a result, AWE is putting in place an extensive research and development programme to better understand the effects that radiation has on the ability to profile human DNA, and assess the associated retention of different radioactive contaminants within each step of the profiling procedure. A summary will be provided on the aims of this project and progress that has been made to date; together with a discussion of the lessons that have been learnt during the course of the programme's development. (author)

  19. Acoustic radiation force due to arbitrary incident fields on spherical particles in soft tissue

    Energy Technology Data Exchange (ETDEWEB)

    Treweek, Benjamin C., E-mail: btreweek@utexas.edu; Ilinskii, Yurii A.; Zabolotskaya, Evgenia A.; Hamilton, Mark F. [Applied Research Laboratories, The University of Texas at Austin, P.O. Box 8029, Austin, TX 78713-8029 (United States)

    2015-10-28

    Acoustic radiation force is of interest in a wide variety of biomedical applications ranging from tissue characterization (e.g. elastography) to tissue treatment (e.g. high intensity focused ultrasound, kidney stone fragment removal). As tissue mechanical properties are reliable indicators of tissue health, the former is the focus of the present contribution. This is accomplished through an investigation of the acoustic radiation force on a spherical scatterer embedded in tissue. Properties of both the scatterer and the surrounding tissue are important in determining the magnitude and the direction of the force. As these properties vary, the force computation shows changes in magnitude and direction, which may enable more accurate noninvasive determination of tissue properties.

  20. Low Incidence of Fatigue after Hypofractionated Stereotactic Body Radiation Therapy (SBRT for Localized Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Chiranjeev eDash

    2012-10-01

    Full Text Available Background: Fatigue is a common side-effect of conventional prostate cancer radiation therapy. The increased delivery precision necessitated by the high dose per fraction of stereotactic body radiation therapy (SBRT offers the potential of reduce target volumes and hence the exposure of normal tissues to high radiation doses. Herein, we examine the level of fatigue associated with SBRT treatment.Methods: Forty patients with localized prostate cancer treated with hypofractionated SBRT, and a minimum of 12 months follow-up were included in this analysis. Self-reported fatigue and other quality of life measures were assessed at baseline and at 1, 3, 6, 9, and 12 months post-SBRT.Results: Mean levels of fatigue were elevated at 1 month post-SBRT compared to baseline values (p=0.02. Fatigue at the 3-month follow-up and later were higher but not statistically significantly different compared to baseline. African-American patients reported higher fatigue post-SBRT than Caucasian patients. Fatigue was correlated with hormonal symptoms as measured by the Expanded Prostate Cancer Index Composite (EPIC quality of life questionnaire, but not with urinary, bowel, or sexual symptoms. Age, co-morbidities, smoking, prostate specific antigen (PSA levels, testosterone levels, and tumor stage were not associated with fatigue. Conclusion: This is the first study to investigate fatigue as a side-effect of SBRT. In contrast to standard radiation therapy, results suggest SBRT-related fatigue is short-term rather than a long-term side effect of SBRT. These results also suggest post-SBRT fatigue to be a more frequent complication in African-Americans than Caucasians.

  1. Estimating Photosynthetic Radiation Use Efficiency Using Incident Light and Photosynthesis of Individual Leaves

    OpenAIRE

    ROSATI, A.; DEJONG, T. M.

    2003-01-01

    It has been theorized that photosynthetic radiation use efficiency (PhRUE) over the course of a day is constant for leaves throughout a canopy if leaf nitrogen content and photosynthetic properties are adapted to local light so that canopy photosynthesis over a day is optimized. To test this hypothesis, ‘daily’ photosynthesis of individual leaves of Solanum melongena plants was calculated from instantaneous rates of photosynthesis integrated over the daylight hours. Instantaneous photosynthes...

  2. Detection of fissionable materials in cargoes using monochromatic photon radiography

    Science.gov (United States)

    Danagoulian, Areg; Lanza, Richard; O'Day, Buckley; LNSP Team

    2015-04-01

    The detection of Special Nuclear Materials (e.g. Pu and U) and nuclear devices in the commercial cargo traffic is one of the challenges posed by the threat of nuclear terrorism. Radiography and active interrogation of heavily loaded cargoes require ~ 1 - 10MeV photons for penetration. In a proof-of-concept system under development at MIT, the interrogating monochromatic photon beam is produced via a 11B(d , nγ) 12C reaction. To achieve this, a boron target is used along with the 3 MeV d+ RFQ accelerator at MIT-Bates. The reactions results in the emission of very narrow 4.4 MeV and 15.1 MeV gammas lines. The photons, after traversing the cargo, are detected by an array of NaI(Tl) detectors. A spectral analysis of the transmitted gammas allows to independently determine the areal density and the atomic number (Z) of the cargo. The proposed approach could revolutionize cargo inspection, which, in its current fielded form has to rely on simple but high dose bremsstrahlung sources. Use of monochromatic sources would significantly reduce the necessary dose and allow for better determination of the cargo's atomic number. The general methodology will be described and the preliminary results from the proof-of-concept system will be presented and discussed. Supported by NSF/DNDO Collaborative Research ARI-LA Award ECCS-1348328.

  3. A versatile lattice for a tau-charm factory that includes a monochromatization scheme

    International Nuclear Information System (INIS)

    Faus-Golfe, A.; Le Duff, J.

    1992-02-01

    A double ring system with multibunch scheme and high luminosity is discussed. An attempt for beam monochromatization at the crossing point was made by increasing the vertical bending angle, and it succeeded in providing a proper matching. The next step consisted of demonstrating that the new ring geometry that permits a monochromatization scheme could be returned and rematched to operate without monochromatization, allowing only relocation of quadrupoles and readjustment of their gradient in the sloping region. The results of this work are reported after a brief recall of the monochromatization scheme requirements. (K.A.) 10 refs., 13 figs., 2 tabs

  4. Calculation of radiation and pair production probabilities at arbitrary incidence angles to crystal planes

    International Nuclear Information System (INIS)

    Tikhonirov, V.V.

    1993-01-01

    The results of calculations of the intensity and polarization of radiation from channeled and unchanneled e +- are presented. The Fourier transformation (FT) is used to calculate numerous matrix elements. The calculations for channeled e + showed fast approach of spectral intensity to its value calculated in the approximation of self-consistent field (ASCF) with growing photon energy. In the case of 150 GeV unchanneled e - in Ge at T=293 K the ASCF gives a significantly higher value as compared to the FT. 4 refs., 3 figs

  5. Radiation factors and smoking interaction at lung cancer incidence for workers at a nuclear enterprise

    International Nuclear Information System (INIS)

    Tokarskaya, Z.B.; Khokhryakov, V.T.; Okladnikova, N.D.; Belyaeva, Z.D.; Zhuntova, G.V.; Fleck, C.M.; Schollnberger, H.; Drozhko, E.G.

    1998-01-01

    A study is reported which is a continuation of a previous investigation of lung cancer incidence in workers at a nuclear enterprise and its relation to three basic etiological factors: the body burden due to 239 Pu, chronic external gamma irradiation, and smoking. Whereas previously each of the factors was assessed separately, in the present study the attempt was made to assess the interaction of the factors. A statistical analysis of the data revealed that for the following pairs of factors a superposition effect could be seen: external gamma irradiation and 239 Pu body burden; external gamma irradiation and a medium level of smoking; and 239 Pu body burden and a medium level of smoking. (A.K.)

  6. Incident report and estimates of personnel exposure for a staff present in maze corridor of linac room while radiation beam on

    International Nuclear Information System (INIS)

    Ravichandran, R.; Davis, C.A.; Ghamrawy, Kamal El; Arunkumar, L.S.

    2007-01-01

    The radiation safety features of high energy linear accelerator installations include primary and secondary barriers made of concrete (radiation bunkers), provision of maze wall for eliminating first scatter reaching the entrance door, locating room entrance perpendicular to maze corridor to reduce neutron dose. In addition, special motorized doors with lead lining and paraffin blocks, electrically interlocked to beam on-off system is provided for radiation safety. A radiation incident took place involving presence of a staff inside the Clinac 2300 CD room in September 2006 has been described

  7. Correlation between the time-series of air temperature and incident solar radiation at Port Harcourt, Nigeria

    International Nuclear Information System (INIS)

    Adjepong, S.K.; Okujagu, C.

    1987-12-01

    We present the preliminary results of an investigation of the correlation between the temporal variations of the time-series of ground air temperature and incident solar radiation recorded at Port Harcourt (lat. 4 deg. 51' N, long. 7 deg. 01' E), Nigeria, during a five-year period (1981 through 1985). Computed cross-correlation functions of the daily time-series reveal correlation at time lags which are approximate harmonics of the 27-day solar rotation cycle. The cross-correlation function of the mean monthly series shows correlation at a time lag of 12 months implying a dominant annual-cycle component in the variation of either series. (author). 12 refs, 2 figs

  8. Use of risk projection models to estimate mortality and incidence from radiation-induced breast cancer in screening programs

    International Nuclear Information System (INIS)

    Ramos, M; Ferrer, S; Villaescusa, J I; Verdu, G; Salas, M D; Cuevas, M D

    2005-01-01

    The authors report on a method to calculate radiological risks, applicable to breast screening programs and other controlled medical exposures to ionizing radiation. In particular, it has been applied to make a risk assessment in the Valencian Breast Cancer Early Detection Program (VBCEDP) in Spain. This method is based on a parametric approach, through Markov processes, of hazard functions for radio-induced breast cancer incidence and mortality, with mean glandular breast dose, attained age and age-at-exposure as covariates. Excess relative risk functions of breast cancer mortality have been obtained from two different case-control studies exposed to ionizing radiation, with different follow-up time: the Canadian Fluoroscopy Cohort Study (1950-1987) and the Life Span Study (1950-1985 and 1950-1990), whereas relative risk functions for incidence have been obtained from the Life Span Study (1958-1993), the Massachusetts tuberculosis cohorts (1926-1985 and 1970-1985), the New York post-partum mastitis patients (1930-1981) and the Swedish benign breast disease cohort (1958-1987). Relative risks from these cohorts have been transported to the target population undergoing screening in the Valencian Community, a region in Spain with about four and a half million inhabitants. The SCREENRISK software has been developed to estimate radiological detriments in breast screening. Some hypotheses corresponding to different screening conditions have been considered in order to estimate the total risk associated with a woman who takes part in all screening rounds. In the case of the VBCEDP, the total radio-induced risk probability for fatal breast cancer is in a range between [5 x 10 -6 , 6 x 10 -4 ] versus the natural rate of dying from breast cancer in the Valencian Community which is 9.2 x 10 -3 . The results show that these indicators could be included in quality control tests and could be adequate for making comparisons between several screening programs

  9. Epidemiological studies on disturbances of human fetal development in areas with various doses of natural background radiation. I. Relationship between incidences of Down's syndrome or visible malformation and gonad dose equivalent rate of natural background radiation

    International Nuclear Information System (INIS)

    Ujeno, Y.

    1985-01-01

    The relationship between environmental radiation to the gonads and incidences of Down's syndrome and visible malformation was analyzed using Kendall's rank correlation method. The subjects, studied during a 3-yr period (1979-1981), were inhabitants of 46 prefectures in Japan that had various dose rates of natural background ionizing radiation. Results showed that the natural background very low-dose radiation rate was not a predominant factor responsible for inducing Down's syndrome or other visible malformations

  10. The incidence of radiation necrosis following stereotactic radiotherapy for melanoma brain metastases: the potential impact of immunotherapy.

    Science.gov (United States)

    Kaidar-Person, Orit; Zagar, Timothy M; Deal, Allison; Moschos, Stergios J; Ewend, Matthew G; Sasaki-Adams, Deanna; Lee, Carrie B; Collichio, Frances A; Fried, David; Marks, Lawrence B; Chera, Bhishamjit S

    2017-07-01

    Stereotactic radiotherapy (SRT) is the standard treatment for patients with limited number of brain metastases. In the past few years, newer immunotherapies (immune checkpoint inhibitors) have been proven to prolong survival in patients with metastatic melanoma. The safety of the combination of SRT and immunotherapy for brain metastases is unknown. We retrospectively identified patients with melanoma brain metastases treated with SRT between 2007 and 2015. Patients who did not have at least 3 months of follow-up with imaging after SRT were excluded from the analysis. Outcomes were compared between patients who were treated with or without immunotherapy. A total of 58 patients were included; of these, 29 were treated with SRT and immunotherapy. MAPK inhibitors (BRAF, MEK inhibitors) were used more often in the immunotherapy group (nine vs. two patients). There was a higher incidence of intracranial complications in patients treated with immunotherapy and SRT. Eight patients had radiation necrosis; all occurred in patients who were treated with immunotherapy. Nine patients had hemorrhage, of which seven occurred in patients who were treated with immunotherapy (P=0.08). However, patients treated with immunotherapy and SRT had a significant overall survival advantage compared with SRT without immunotherapy (15 vs. 6 months, P=0.0013). Patients treated with SRT and immunotherapy have a higher incidence/risk of intracranial complications, but a longer overall survival.

  11. Monochromatic minibeam radiotherapy: theoretical and experimental dosimetry for preclinical treatment plans

    Energy Technology Data Exchange (ETDEWEB)

    Deman, P; Vautrin, M; Stupar, V; Barbier, E L; Elleaume, H; Esteve, F; Adam, J F, E-mail: adam@esrf.fr [INSERM, U836, BP 170, Grenoble Cedex 9, F-38042 (France)

    2011-07-21

    Monochromatic x-ray minibeam radiotherapy is a new radiosurgery approach based on arrays of submillimetric interlaced planar x-ray beams. The aim of this study was to characterize the dose distributions obtained with this new modality when being used for preclinical trials. Monte Carlo simulations were performed in water phantoms. Percentage depth-dose curves and dose profiles were computed for single incidences and interleaved incidences of 80 keV planar x-ray minibeam (0.6 x 5 mm) arrays. Peak to valley dose ratios were also computed at various depths for an increasing number of minibeams. 3D experimental polymer gel (nPAG) dosimetry measurements were performed using MRI devices designed for small animal imaging. These very high spatial resolution (50 {mu}m) dose maps were compared to the simulations. Preclinical minibeams dose distributions were fully characterized. Experimental dosimetry correlated well with Monte Carlo calculations (Student t-tests: p > 0.1). F98 tumor-bearing rats were also irradiated with interleaved minibeams (80 keV, prescribed dose: 25 Gy). This associated preclinical trial serves as a proof of principle of the technique. The mean survival time of irradiated glioma-bearing rats increased significantly, when compared to the untreated animals (59.6 {+-} 2.8 days versus 28.25 {+-} 0.75 days, p < 0.001).

  12. Atmospheric turbidity parameters affecting the incident solar solar radiation for two different areas in (Eg))

    International Nuclear Information System (INIS)

    Tadros, M.T.Y.; Mosalam, M.A.; El-metwally, M.

    1999-01-01

    Atmospheric turbidity parameters such as Linke turbidity (L-0) and true Angstrom parameters (Bita o , Alpha 0 ) have been determined from the measurements of direct solar radiation for entire spectrum and for specified spectral bands during one year starting from june 1992 to may 1993. Comparison between the industrial area in Helwan (south Cairo) with that of the agricultural area in Mansoura, in (Eg), was done. Analysis of data revealed that the atmospheric turbidity parameters (L Beta) in Helwan is higher than that in Mansoura, except for hot wet months. The increase of L in Mansoura, in summer, is due to the increase of water vapor content. The wavelength exponent Alpha shows that the size the size of particles in Helwan is larger than that in Mansoura

  13. Earth Reflected Solar Radiation Incident upon an Arbitrarily Oriented Spinning Flat Plate

    Science.gov (United States)

    Cunningham, Fred G.

    1963-01-01

    A general derivation is given for the earth reflected solar radiation input to a flat plate--a solar cell paddle, for example--which is spinning about an axis coincident with the axis of symmetry of the satellite to which it is affixed. The resulting equations are written for the general case so that arbitrary orientations of the spin axis with respect to the earth-satellite line and arbitrary orientations of the normal to the plate with respect to the spin axis can be treated. No attempt is made to perform the resulting integrations because of the complexity of the equations; nor is there any attempt to delineate the integration limits for the general case. However, the equations governing these limits are given. The appendixes contain: the results, in graphical form, of two representative examples; the general computer program for the calculation is given in Fortran notation; and the results of a calculation of the distribution of albedo energy on the proposed Echo II satellite. The value of the mean solar constant used is 1.395 times 10 (sup 4) ergs per centimeters-squared per second; the mean albedo of the earth is assumed to be 0.34; and the earth is assumed to be a diffuse reflector.

  14. High resolution, monochromatic x-ray topography capability at CHESS

    Energy Technology Data Exchange (ETDEWEB)

    Finkelstein, K. D., E-mail: kdf1@cornell.edu; Pauling, A.; Brown, Z. [CHESS, Cornell University, Ithaca, NY (United States); Jones, R. [Department of Physics, University of Connecticut, Storrs, CT (United States); Tarun, A.; Misra, D. S. [IIa Technologies (Singapore); Jupitz, S. [St. Mary’s College of Maryland, St. Mary’s City, MD (United States); Sagan, D. C. [CLASSE, Cornell University, Ithaca, NY (United States)

    2016-07-27

    CHESS has a monochromatic x-ray topography capability serving continually expanding user interest. The setup consists of a beam expanding monochromator, 6-circle diffactometer, and CHESS designed CMOS camera with real time sample-alignment capability. This provides rocking curve mapping with angle resolution as small as 2 µradians, spatial resolution to 3 microns, and field of view up to 7mm. Thus far the capability has been applied for: improving CVD-diamond growth, evaluating perfection of ultra-thin diamond membranes, correlating performance of diamond-based electronics with crystal defect structure, and defect analysis of single crystal silicon carbide. This paper describes our topography system, explains its capabilities, and presents experimental results from several applications.

  15. High resolution, monochromatic x-ray topography capability at CHESS

    International Nuclear Information System (INIS)

    Finkelstein, K. D.; Pauling, A.; Brown, Z.; Jones, R.; Tarun, A.; Misra, D. S.; Jupitz, S.; Sagan, D. C.

    2016-01-01

    CHESS has a monochromatic x-ray topography capability serving continually expanding user interest. The setup consists of a beam expanding monochromator, 6-circle diffactometer, and CHESS designed CMOS camera with real time sample-alignment capability. This provides rocking curve mapping with angle resolution as small as 2 µradians, spatial resolution to 3 microns, and field of view up to 7mm. Thus far the capability has been applied for: improving CVD-diamond growth, evaluating perfection of ultra-thin diamond membranes, correlating performance of diamond-based electronics with crystal defect structure, and defect analysis of single crystal silicon carbide. This paper describes our topography system, explains its capabilities, and presents experimental results from several applications.

  16. Physics Reach with a Monochromatic Neutrino Beam from Electron Capture

    CERN Document Server

    Bernabeu, J.; Espinoza, C.; Lindroos, M.

    2005-01-01

    Neutrino oscillation experiments from different sources have demonstrated non-vanishing neutrino masses and flavour mixings. The next experiments have to address the determination of the connecting mixing U(e3) and the existence of the CP violating phase. Whereas U(e3) measures the strength of the oscillation probability in appearance experiments, the CP phase acts as a phase-shift in the interference pattern. Here we propose to separate these two parameters by energy dependence, using the novel idea of a monochromatic neutrino beam facility based on the acceleration of ions that decay fast through electron capture. Fine tuning of the boosted neutrino energy allows precision measurements able to open a window for the discovery of CP violation, even for a mixing as small as 1 degree

  17. Late effects of selected immunosuppressants on immunocompetence, disease incidence, and mean life-span. III. Disease incidence and life expectancy. [Mice, x radiation

    Energy Technology Data Exchange (ETDEWEB)

    Peter, C P; Perkins, E H; Peterson, W J; Walburg, H E; Makinodan, T

    1975-01-01

    The effect of various immunosuppressive treatments on mean life-span and disease incidence have been studied. Significant life shortening was seen only in mice which received X-irradiation early in life and can be ascribed primarily to an increased incidence of certain malignancies. Marginal life shortening was seen in cyclophosphamide-treated animals, however, survival patterns between those and control animals did not differ until 30 months of age and the magnitude of life-shortening never approached that seen in X-irradiated animals. Thymectomy, splenectomy or cortisone treatment did not alter survival. All immunosuppressive treatments enhanced mortality due to non-neoplastic diseases, however, only a small percentage of animals die with these disease entities. With the exception of cortisone all immunosuppressive treatments increased the incidence of neoplastic disease. However, their effects on various neoplastic processes were variable and unpredictable. Four primary patterns in terms of relative immune competence, disease incidence and life expectancy were seen. Thus, immunodepression may or may not correlate with increased disease incidence, which in turn may or may not have a life-shortening effect. These findings are discussed in terms of the marked reduction of both humoral and cell-mediated immunity normally seen in aged mice and the significance of postulated immune surveillance mechanisms to survival.

  18. Modeling Photosynthetically Active Radiation in Water of Tampa Bay, Florida, with Emphasis on the Geometry of Incident Irradiance

    Science.gov (United States)

    Miller, Ronald L.; McPherson, Benjamin F.

    1995-04-01

    Field studies that compare the spatial and temporal variation in light attenuation often neglect effects of solar elevation angle, yet these effects can be significant. To approximately correct for these angular effects, we developed a model that uses a simplified geometric description of incident direct solar beam and diffuse skylight. The model incorporates effects of solar elevation angle and cloudiness on the amount of in-air photosynthetically active radiation (PAR) that passes through the air-water interface and on K0in waters of relatively low turbidity. The model was calibrated with 3266 5-min averages of scalar PAR measured in air and at two depths in water and permits the value of K0to be adjusted approximately for the effects of time of day, season and cloudiness. The model was then used with 255 days of in-air PAR data (15-min averages) to evaluate irradiance that entered the water and attenuation in the water. On an annual basis, 49% of the incident scalar irradiance, or 380 μmol m -2s -1, was estimated to enter the water of Tampa Bay. The value of K0was estimated to vary as much as 41% on a clear summer day due to changes in solar elevation angle. The model was used to make estimates of the depth to which sea-grasses might receive adequate light for survival for a range of values of K0. This approach should be useful for projecting the effect of changes in water clarity on the depth of sea-grass survival and for comparing values of K0collected at different times of day and in different seasons.

  19. Training of an incidence of radiation on surfaces by vectorial representation; Didactica del analisis de la incidencia de radiacion solar mediante una representacion vectorial

    Energy Technology Data Exchange (ETDEWEB)

    Luis, F. J. de; Perez-Garcia, M.; Barbero, F. J.; Batlles, F. J.

    2004-07-01

    This work gathers and it exposes a set of educational contents extracted from the general bibliography and from the own experience in Engineering studies and courses on the application of a vector representation to the description of the apparent movement of the sun, the shading evaluation and the incidence of radiation on surfaces. (Author)

  20. Measurement of the radiation incident on ALS NdFeB permanent magnet insertion device structures and a determination of their lifetime

    International Nuclear Information System (INIS)

    Krebs, G.F.; Holmes, M.

    1997-05-01

    Measurements of the radiation incident on ALS insertion device NdFeB permanent magnet structures were carried out using thermoluminescence dosimeters. A plastic scintillator gamma telescope was utilized to unravel the various contributions to the integrated dose. Magnet lifetimes were calculated for various operational conditions

  1. Error sources in the real-time NLDAS incident surface solar radiation and an evaluation against field observations and the NARR

    Science.gov (United States)

    Park, G.; Gao, X.; Sorooshian, S.

    2005-12-01

    The atmospheric model is sensitive to the land surface interactions and its coupling with Land surface Models (LSMs) leads to a better ability to forecast weather under extreme climate conditions, such as droughts and floods (Atlas et al. 1993; Beljaars et al. 1996). However, it is still questionable how accurately the surface exchanges can be simulated using LSMs, since terrestrial properties and processes have high variability and heterogeneity. Examinations with long-term and multi-site surface observations including both remotely sensed and ground observations are highly needed to make an objective evaluation on the effectiveness and uncertainty of LSMs at different circumstances. Among several atmospheric forcing required for the offline simulation of LSMs, incident surface solar radiation is one of the most significant components, since it plays a major role in total incoming energy into the land surface. The North American Land Data Assimilation System (NLDAS) and North American Regional Reanalysis (NARR) are two important data sources providing high-resolution surface solar radiation data for the use of research communities. In this study, these data are evaluated against field observations (AmeriFlux) to identify their advantages, deficiencies and sources of errors. The NLDAS incident solar radiation shows a pretty good agreement in monthly mean prior to the summer of 2001, while it overestimates after the summer of 2001 and its bias is pretty close to the EDAS. Two main error sources are identified: 1) GOES solar radiation was not used in the NLDAS for several months in 2001 and 2003, and 2) GOES incident solar radiation when available, was positively biased in year 2002. The known snow detection problem is sometimes identified in the NLDAS, since it is inherited from GOES incident solar radiation. The NARR consistently overestimates incident surface solar radiation, which might produce erroneous outputs if used in the LSMs. Further attention is given to

  2. Fusion of colour and monochromatic images with edge emphasis

    Directory of Open Access Journals (Sweden)

    Rade M. Pavlović

    2014-02-01

    Full Text Available We propose a novel method to fuse true colour images with monochromatic non-visible range images that seeks to encode important structural information from monochromatic images efficiently but also preserve the natural appearance of the available true chromacity information. We utilise the β colour opponency channel of the lαβ colour as the domain to fuse information from the monochromatic input into the colour input by the way of robust grayscale fusion. This is followed by an effective gradient structure visualisation step that enhances the visibility of monochromatic information in the final colour fused image. Images fused using this method preserve their natural appearance and chromacity better than conventional methods while at the same time clearly encode structural information from the monochormatic input. This is demonstrated on a number of well-known true colour fusion examples and confirmed by the results of subjective trials on the data from several colour fusion scenarios. Introduction The goal of image fusion can be broadly defined as: the representation of visual information contained in a number of input images into a single fused image without distortion or loss of information. In practice, however, a representation of all available information from multiple inputs in a single image is almost impossible and fusion is generally a data reduction task.  One of the sensors usually provides a true colour image that by definition has all of its data dimensions already populated by the spatial and chromatic information. Fusing such images with information from monochromatic inputs in a conventional manner can severely affect natural appearance of the fused image. This is a difficult problem and partly the reason why colour fusion received only a fraction of the attention than better behaved grayscale fusion even long after colour sensors became widespread. Fusion method Humans tend to see colours as contrasts between opponent

  3. Evaluation of the Reanalysis Surface Incident Shortwave Radiation Products from NCEP, ECMWF, GSFC, and JMA Using Satellite and Surface Observations

    Directory of Open Access Journals (Sweden)

    Xiaotong Zhang

    2016-03-01

    Full Text Available Solar radiation incident at the Earth’s surface (Rs is an essential component of the total energy exchange between the atmosphere and the surface. Reanalysis data have been widely used, but a comprehensive validation using surface measurements is still highly needed. In this study, we evaluated the Rs estimates from six current representative global reanalyses (NCEP–NCAR, NCEP-DOE; CFSR; ERA-Interim; MERRA; and JRA-55 using surface measurements from different observation networks [GEBA; BSRN; GC-NET; Buoy; and CMA] (674 sites in total and the Earth’s Radiant Energy System (CERES EBAF product from 2001 to 2009. The global mean biases between the reanalysis Rs and surface measurements at all sites ranged from 11.25 W/m2 to 49.80 W/m2. Comparing with the CERES-EBAF Rs product, all the reanalyses overestimate Rs, except for ERA-Interim, with the biases ranging from −2.98 W/m2 to 21.97 W/m2 over the globe. It was also found that the biases of cloud fraction (CF in the reanalyses caused the overestimation of Rs. After removing the averaged bias of CERES-EBAF, weighted by the area of the latitudinal band, a global annual mean Rs values of 184.6 W/m2, 180.0 W/m2, and 182.9 W/m2 were obtained over land, ocean, and the globe, respectively.

  4. Comparison of incidences of normal tissue complications with tumor response in a phase III trial comparing heat plus radiation to radiation alone

    International Nuclear Information System (INIS)

    Dewhirst, M.W.; Sim, D.A.; Grochowski, K.J.

    1984-01-01

    The success of hyperthermia (/sup Δ/) as an adjuvant to radiation (XRT) will depend on whether the increase in tumor control is greater than that for normal tissue reactions. One hundred and thirty dogs and cats were stratified by histology and randomized to receive XRT (460 rads per fraction, two fractions per week, for eight fractions) or /sup Δ/ + XRT (30 min. at 44 +-2 0 C; one fraction per week, four fractions; immediately prior to XRT). Heat induced changes in tumor and normal tissue responses were made by comparing ratios of incidence for /sup Δ/ + XRT and XRT alone (TRR; Thermal Relative Risk). Change in tumor response duration was calculated from statistical analysis of response duration curves (RRR; Relative Relapse Rate). Heat increased early normal tissue reactions (moist desquamation and mucositis by a factor of 1.08. Tumor complete response, by comparison, was significantly improved (TRR = 2.12, p < .001). Late skin fibrosis was also increased (TRR = 1.51), but the prolongation in tumor response was greater (RRR 1.85). The degree of thermal enhancement for all tissues was dependent on the minimum temperature achieved on the first treatment, but the values for tumor were consistently greater than those achieved for normal tissues

  5. Isolated lung events following radiation for early stage breast cancer: incidence and predictors for primary lung vs metastatic breast cancer

    International Nuclear Information System (INIS)

    Van Buren, Teresa A; Harris, Jay R; Sugarbaker, David J; Schneider, Lindsey; Healey, Elizabeth A

    1995-01-01

    Purpose: 1) To define the incidence of isolated lung events in a cohort of women treated with conservative surgery (CS) and radiation therapy (RT) for early stage breast cancer. 2) Among such patients, to define the relative distribution of primary lung cancer, metastatic breast cancer, and indeterminate lesions; and to identify any predictors for a diagnosis of lung vs metastatic breast cancer. 3) To examine the cohort with respect to whether a higher than expected incidence of lung cancer is seen following breast irradiation. Materials and Methods: Between 1968 and 1986, 1865 patients with clinical stage I-II breast cancer were treated with CS and RT; the median follow-up for surviving patients is 129 months. The study population was limited to patients who developed a subsequent isolated lung event as the first site of distant disease. Isolated lung event was defined as disease limited to the thoracic cavity, without evidence of either uncontrolled local breast disease or metastatic disease elsewhere. Diagnosis of the lung event as a primary lung cancer, a metastatic breast lesion, or an indeterminate lesion was documented from the viewpoint of 1) the pathologic analysis and 2) the clinical impression at the time of the lung event. Results: Sixty six of the 1865 patients (3.5%) developed an isolated lung event. The relative distribution of the pathologic and clinical diagnoses is shown below: The 66 lung events were characterized either as a solitary pulmonary nodule (27), multiple nodules (23), pleural effusion alone (10), unknown (2), or miscellaneous other findings (4). Among the 47 patients for whom pathology was available, the diagnosis remained indeterminate for 24 (51%). For patients with a definitive pathologic diagnosis, 69% ((9(13))) of smokers had a new lung cancer compared to 20% ((2(10))) of non-smokers (p=0.036), and 67% ((10(15))) of patients with a solitary pulmonary nodule had lung cancer compared to 14% ((1(7))) for other lung presentations (p

  6. Cell response to quasi-monochromatic light with different coherence

    Energy Technology Data Exchange (ETDEWEB)

    Budagovsky, A V; Solovykh, N V [I.V.Michurin All-Russian Recearch Institute of Fruit Crops Genetics and Breeding (Russian Federation); Budagovskaya, O N [I.V.Michurin All-Russia Research and Development Institute of Gardening, Michurinsk, Tambov region (Russian Federation); Budagovsky, I A [P N Lebedev Physics Institute, Russian Academy of Sciences, Moscow (Russian Federation)

    2015-04-30

    The problem of the light coherence effect on the magnitude of the photoinduced cell response is discussed. The origins of ambiguous interpretation of the known experimental results are considered. Using the biological models, essentially differing in anatomy, morphology and biological functions (acrospires of radish, blackberry microsprouts cultivated in vitro, plum pollen), the effect of statistical properties of quasi-monochromatic light (λ{sub max} = 633 nm) on the magnitude of the photoinduced cell response is shown. It is found that for relatively low spatial coherence, the cell functional activity changes insignificantly. The maximal enhancement of growing processes (stimulating effect) is observed when the coherence length L{sub coh} and the correlation radius r{sub cor} are greater than the cell size, i.e., the entire cell fits into the field coherence volume. In this case, the representative indicators (germination of seeds and pollen, the spears length) exceeds those of non-irradiated objects by 1.7 – 3.9 times. For more correct assessment of the effect of light statistical properties on photocontrol processes, it is proposed to replace the qualitative description (coherent – incoherent) with the quantitative one, using the determination of spatial and temporal correlation functions and comparing them with the characteristic dimensions of the biological structures, e.g., the cell size. (biophotonics)

  7. Properties of light transition radiation of 660 MeV proton inclined incidence (γ=1.7) on a thick nickel plate. II

    International Nuclear Information System (INIS)

    Zrelov, V.P.; Pavlovic, P.; Ruzicka, J.

    1975-01-01

    The basic properties of transition radiation in the visible fraction of the spectrum have been calculated for 660 MeV protons (γ=1.7) obliquely incident on a thick nickel plate in vacuum. The angular distributions of the summary radiation (i.e. the sums of radiations of various polarizations) both 'forward' and 'backward' for different azimuthal planes are presented in tables and diagrams for different particle inclination angles to the separation boundary. The examples of angular distributions of radiation having various polarizations (at the inclination angle of 45 0 ) show that they differ considerably. The spectra of summary radiation are of a monotonous character. The calculations have shown that in a relativistic case the forward radiation is concentrated near the direction of particle motion and backward radiation moves in an opposite direction with respect to that of the particle inclination. The dependence of the total yield of forward and backward transition radiations upon the particle inclination angle is approximately cos 2 psi. (Auth.)

  8. Calibration of photographic dosemeters to evaluate the personal equivalent dose, Hp (10), irradiated by different radiation qualities and angles of incidence

    International Nuclear Information System (INIS)

    Santoro, Christiana; Antonio Filho, Joao

    2013-01-01

    To use radiation detectors, should periodically perform tests and calibrations on instruments in order to verify its good functionality. One way to ascertain the quality of the instrument is to conduct a study of the angular dependence of the response of the radiation detectors. The photographic dosimetry has been used widely to quantify the radiation doses and to estimate levels of doses received by workers involved with X-and gamma radiation. Photographic dosimeters are used because provide wide range of exposure and good accuracy. One of the sources of error have been introduced by different irradiation geometries between calibration and measurement in radiation fields used in x-ray and gamma ray sources, therefore, there is a need for an evaluation of the sensitivity of dosimeters with variation of the angle of the incident beam. In this study were tested 190 photographic dosemeters in the Metrology Laboratory of the Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE) using the phantom H p (10), where the dosimeters are evaluated on the basis of the new operational magnitude for individual monitoring, the equivalent personal dose, H p (10). Angular dependence of these radiation detectors was studied in X radiation fields (in the range of 45 keV energy to 164 keV) and gamma radiation ( 137 Cs-662 keV e 60 Co - 1250 keV)

  9. Maximum dose angle for oblique incidence on primary beam protective barriers in the design of medical radiation therapy facilities

    International Nuclear Information System (INIS)

    Fondevila, Damian; Arbiser, Silvio; Sansogne, Rosana; Brunetto, Monica; Dosoretz, Bernardo

    2008-01-01

    Primary barrier determinations for the shielding of medical radiation therapy facilities are generally made assuming normal beam incidence on the barrier, since this is geometrically the most unfavorable condition for that shielding barrier whenever the occupation line is allowed to run along the barrier. However, when the occupation line (for example, the wall of an adjacent building) runs perpendicular to the barrier (especially roof barrier), then two opposing factors come in to play: increasing obliquity angle with respect to the barrier increases the attenuation, while the distance to the calculation point decreases, hence, increasing the dose. As a result, there exists an angle (α max ) for which the equivalent dose results in a maximum, constituting the most unfavorable geometric condition for that shielding barrier. Based on the usual NCRP Report No. 151 model, this article presents a simple formula for obtaining α max , which is a function of the thickness of the barrier (t E ) and the equilibrium tenth-value layer (TVL e ) of the shielding material for the nominal energy of the beam. It can be seen that α max increases for increasing TVL e (hence, beam energy) and decreases for increasing t E , with a range of variation that goes from 13 to 40 deg for concrete barriers thicknesses in the range of 50-300 cm and most commercially available teletherapy machines. This parameter has not been calculated in the existing literature for radiotherapy facilities design and has practical applications, as in calculating the required unoccupied roof shielding for the protection of a nearby building located in the plane of the primary beam rotation

  10. Maximum dose angle for oblique incidence on primary beam protective barriers in the design of medical radiation therapy facilities.

    Science.gov (United States)

    Fondevila, Damián; Arbiser, Silvio; Sansogne, Rosana; Brunetto, Mónica; Dosoretz, Bernardo

    2008-05-01

    Primary barrier determinations for the shielding of medical radiation therapy facilities are generally made assuming normal beam incidence on the barrier, since this is geometrically the most unfavorable condition for that shielding barrier whenever the occupation line is allowed to run along the barrier. However, when the occupation line (for example, the wall of an adjacent building) runs perpendicular to the barrier (especially roof barrier), then two opposing factors come in to play: increasing obliquity angle with respect to the barrier increases the attenuation, while the distance to the calculation point decreases, hence, increasing the dose. As a result, there exists an angle (alpha(max)) for which the equivalent dose results in a maximum, constituting the most unfavorable geometric condition for that shielding barrier. Based on the usual NCRP Report No. 151 model, this article presents a simple formula for obtaining alpha(max), which is a function of the thickness of the barrier (t(E)) and the equilibrium tenth-value layer (TVL(e)) of the shielding material for the nominal energy of the beam. It can be seen that alpha(max) increases for increasing TVL(e) (hence, beam energy) and decreases for increasing t(E), with a range of variation that goes from 13 to 40 deg for concrete barriers thicknesses in the range of 50-300 cm and most commercially available teletherapy machines. This parameter has not been calculated in the existing literature for radiotherapy facilities design and has practical applications, as in calculating the required unoccupied roof shielding for the protection of a nearby building located in the plane of the primary beam rotation.

  11. Monochromatic neutron beam production at Brazilian nuclear research reactors

    Science.gov (United States)

    Stasiulevicius, Roberto; Rodrigues, Claudio; Parente, Carlos B. R.; Voi, Dante L.; Rogers, John D.

    2000-12-01

    Monochomatic beams of neutrons are obtained form a nuclear reactor polychromatic beam by the diffraction process, suing a single crystal energy selector. In Brazil, two nuclear research reactors, the swimming pool model IEA-R1 and the Argonaut type IEN-R1 have been used to carry out measurements with this technique. Neutron spectra have been measured using crystal spectrometers installed on the main beam lines of each reactor. The performance of conventional- artificial and natural selected crystals has been verified by the multipurpose neutron diffractometers installed at IEA-R1 and simple crystal spectrometer in operator at IEN- R1. A practical figure of merit formula was introduced to evaluate the performance and relative reflectivity of the selected planes of a single crystal. The total of 16 natural crystals were selected for use in the neutron monochromator, including a total of 24 families of planes. Twelve of these natural crystal types and respective best family of planes were measured directly with the multipurpose neutron diffractometers. The neutron spectrometer installed at IEN- R1 was used to confirm test results of the better specimens. The usually conventional-artificial crystal spacing distance range is limited to 3.4 angstrom. The interplane distance range has now been increased to approximately 10 angstrom by use of naturally occurring crystals. The neutron diffraction technique with conventional and natural crystals for energy selection and filtering can be utilized to obtain monochromatic sub and thermal neutrons with energies in the range of 0.001 to 10 eV. The thermal neutron is considered a good tool or probe for general applications in various fields, such as condensed matter, chemistry, biology, industrial applications and others.

  12. The quasi-monochromatic photon beam used in photoneutron experiments from 20-120 MeV at the 600 MeV Saclay Linac

    International Nuclear Information System (INIS)

    Veyssiere, A.; Beil, H.; Bergere, R.; Carlos, P.; Fagot, J.; Lepretre, A.; Ahrens, J.

    1979-01-01

    A beam of 20-130 MeV positrons, with average intensities between 10 nA and 50 nA, is used at the 600 MeV Saclay Linac to create a quasi-monochromatic photon beam with a continuously variable energy. This beam was used to measure photoneutron cross sections and the corresponding photonuclear facility is first described. The computer-controlled methods, implemented to measure the energy spectrum and the emittance of the positron beam are described. The quasi-monochromatic photon lines are produced by the annihilation in flight of monoenergetic positrons in two annihilation radiators with different Z successively. The photon beam emission angle theta is shown to be the most critical parameter in the search for an optimum overall signal to background ratio for a specific photoneutron experiment. The choice of an angle theta approximately 4 0 is explained for absolute measurements of sigma(γ, xn) cross-sections, for which the used average intensities of monochromatic photons were thus purposely reduced to approximately 5 X 10 3 s -1 , with an energy resolution approximately 12%. (Auth.)

  13. A wavelet-coupled support vector machine model for forecasting global incident solar radiation using limited meteorological dataset

    International Nuclear Information System (INIS)

    Deo, Ravinesh C.; Wen, Xiaohu; Qi, Feng

    2016-01-01

    Highlights: • A forecasting model for short- and long-term global incident solar radiation (R_n) has been developed. • The support vector machine and discrete wavelet transformation algorithm has been integrated. • The precision of the wavelet-coupled hybrid model is assessed using several prediction score metrics. • The proposed model is an appealing tool for forecasting R_n in the present study region. - Abstract: A solar radiation forecasting model can be utilized is a scientific contrivance for investigating future viability of solar energy potentials. In this paper, a wavelet-coupled support vector machine (W-SVM) model was adopted to forecast global incident solar radiation based on the sunshine hours (S_t), minimum temperature (T_m_a_x), maximum temperature (T_m_a_x), windspeed (U), evaporation (E) and precipitation (P) as the predictor variables. To ascertain conclusive results, the merit of the W-SVM was benchmarked with the classical SVM model. For daily forecasting, sixteen months of data (01-March-2014 to 30-June-2015) partitioned into the train (65%) and test (35%) set for the three metropolitan stations (Brisbane City, Cairns Aero and Townsville Aero) were utilized. Data were decomposed into their wavelet sub-series by discrete wavelet transformation algorithm and summed up to create new series with one approximation and four levels of detail using Daubechies-2 mother wavelet. For daily forecasting, six model scenarios were formulated where the number of input was increased and the forecast was assessed by statistical metrics (correlation coefficient r; Willmott’s index d; Nash-Sutcliffe coefficient E_N_S; peak deviation P_d_v), distribution statistics and prediction errors (mean absolute error MAE; root mean square error RMSE; mean absolute percentage error MAPE; relative root mean square error RMSE). Results for daily forecasts showed that the W-SVM model outperformed the classical SVM model for optimum input combinations. A sensitivity

  14. The measurement and analysis of normal incidence solar UVB radiation and its application to the photoclimatherapy protocol for psoriasis at the Dead Sea, Israel.

    Science.gov (United States)

    Kudish, Avraham I; Harari, Marco; Evseev, Efim G

    2011-01-01

    The broad-band normal incidence UVB beam radiation has been measured at Neve Zohar, Dead Sea basin, using a prototype tracking instrument composed of a Model 501A UV-Biometer mounted on an Eppley Solar Tracker Model St-1. The diffuse and beam fraction of the solar global UVB radiation have been determined using the concurrently measured solar global UVB radiation. The diffuse fraction was observed to exceed 80% throughout the year. The application of the results of these measurements to the possible revision of the photoclimatherapy protocol for psoriasis patients at the Dead Sea medical spas is now under investigation. The suggested revision would enable the sun-exposure treatment protocol to take advantage of the very high diffuse fraction by allowing the patient to receive the daily dose of UVB radiation without direct exposure to the sun, viz. receive the diffuse UVB radiation under a sunshade. This would require an increase in sun-exposure time intervals, as the UVB radiation intensity beneath a sunshade is less than that on an exposed surface. © 2010 The Authors. Photochemistry and Photobiology © 2010 The American Society of Photobiology.

  15. Increased incidence of myelodysplastic syndrome and acute myeloid leukemia following breast cancer treatment with radiation alone or combined with chemotherapy: a registry cohort analysis 1990-2005

    International Nuclear Information System (INIS)

    Kaplan, Henry G; Malmgren, Judith A; Atwood, Mary K

    2011-01-01

    Our objective was to measure myelodysplastic syndrome (MDS) and acute myelogenous leukemia (AML) risk associated with radiation and/or chemotherapy breast cancer (BC) treatment. Our study cohort was composed of BC patients diagnosed from 1990 to 2005 and followed up for blood disorders, mean length of follow up = 7.17 years, range 2-18 years. 5790 TNM stage 0-III patients treated with surgery alone, radiation and/or chemotherapy were included. Patients without surgery (n = 111), with stem cell transplantation (n = 98), unknown or non-standard chemotherapy regimens (n = 94), lost to follow up (n = 66) or 'cancer status unknown' (n = 67) were excluded. Rates observed at our community based cancer care institution were compared to SEER incidence data for rate ratio (RR) calculations. 17 cases of MDS/AML (10 MDS/7 AML) occurred during the follow up period, crude rate .29% (95% CI = .17, .47), SEER comparison RR = 3.94 (95% CI = 2.34, 6.15). The RR of MDS in patients age < 65 comparing our cohort incidence to SEER incidence data was 10.88 (95% CI = 3.84, 24.03) and the RR of AML in patients age < 65 was 5.32 (95% CI = 1.31, 14.04). No significant increased risk of MDS or AML was observed in women ≥ 65 or the surgery/chemotherapy-only group. A RR of 3.32 (95% CI = 1.42, 6.45) was observed in the surgery/radiation-only group and a RR of 6.32 (95% CI = 3.03, 11.45) in the surgery/radiation/chemotherapy group. 3 out of 10 MDS cases died of disease at an average 3.8 months post diagnosis and five of seven AML cases died at an average 9 months post diagnosis. An elevated rate of MDS and AML was observed among breast cancer patients < 65, those treated with radiation and those treated with radiation and chemotherapy compared to available population incidence data. Although a small number of patients are affected, leukemia risk associated with treatment and younger age is significant

  16. The influence of incident beam's angle offset of Fourier transform infrared spectrometer on the spectrum measurement explored with synchrotron radiation

    International Nuclear Information System (INIS)

    Chen Wenhao; Chen Min; Xiao Tiqiao

    2011-01-01

    Effects of the incident angle offset on FT-IR spectra are investigated in this paper. The simulated FT-IR spectra are obtained by Fourier inverse transform. The results show that this frequency shift varies with the angle offset of the incident beam in FT-IR. As an example,the factors that affect the angle of incident IR light at SSRF are analyzed. According to performance specifications of the IR beamline, requirements of the optical component installation precision and position drift of the light source are given. (authors)

  17. Review of incidents to be reported under the Radiation Protection Ordinance for the years 1987 and 1988

    International Nuclear Information System (INIS)

    1989-01-01

    The total of 80 incidents were caused by human failure, intentional disruption, theft, fire, violation of rules, transport losses, accidents, equipment deficiencies. 15 ionization smoke detectors were reported lost or stolen. (HP) [de

  18. The Semipalatinsk nuclear test site: a first analysis of solid cancer incidence (selected sites) due to test-related radiation.

    Science.gov (United States)

    Gusev, B I; Rosenson, R I; Abylkassimova, Z N

    1998-10-01

    Since 1956, cancer incidences have been analysed in several rayons of the Semipalatinsk oblast, with cross-sectional analyses being conducted every 5 years. Data on different tumor localizations were recorded within a heavily contaminated so-called main area of nine villages (estimated average effective equivalent dose about 2000 mSv) and a so-called control area (estimated average effective equivalent dose about 70 mSv), each including approximately 10000 persons. Up to 1970, the excess cancer incidence in the exposed villages was observed to have increased; after 1970, a decrease was noted, followed by a second increase in the late 1980s. The main sites of excess cancer included the esophagus, stomach, and liver. Up to 1970, the esophagus cancer incidence was predominant, but it decreased thereafter, while the incidence of stomach and liver cancers increased. The second peak of excess cancer rates was mainly due to lung, breast, and thyroid carcinomas.

  19. The electronics in fluorescent bulbs and light emitting diodes (LED), rather than ultraviolet radiation, cause increased malignant melanoma incidence in indoor office workers and tanning bed users.

    Science.gov (United States)

    Milham, Samuel; Stetzer, Dave

    2018-07-01

    The epidemiology of cutaneous malignant melanoma (CMM) has a number of facets that do not fit with sunlight and ultraviolet light as the primary etiologic agents. Indoor workers have higher incidence and mortality rates of CMM than outdoor workers; CMM occurs in body locations never exposed to sunlight; CMM incidence is increasing in spite of use of UV blocking agents and small changes in solar radiation. Installation of two new fluorescent lights in the milking parlor holding area of a Minnesota dairy farm in 2015 caused an immediate drop in milk production. This lead to measurement of body amperage in humans exposed to modern non-incandescent lighting. People exposed to old and new fluorescent lights, light emitting diodes (LED) and compact fluorescent lights (CFL) had body amperage levels above those considered carcinogenic. We hypothesize that modern electric lighting is a significant health hazard, a carcinogen, and is causing increasing CMM incidence in indoor office workers and tanning bed users. These lights generate dirty electricity (high frequency voltage transients), radio frequency (RF) radiation, and increase body amperage, all of which have been shown to be carcinogenic. This could explain the failure of ultraviolet blockers to stem the malignant melanoma pandemic. Tanning beds and non-incandescent lighting could be made safe by incorporating a grounded Faraday cage which allows passage of ultraviolet and visible light frequencies and blocks other frequencies. Modern electric lighting should be fabricated to be electrically clean. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Incidence and mortality of solid cancer among emergency workers of the Chernobyl accident: assessment of radiation risks for the follow-up period of 1992-2009

    Energy Technology Data Exchange (ETDEWEB)

    Kashcheev, V.V.; Chekin, S.Yu.; Maksioutov, M.A.; Tumanov, K.A.; Kochergina, E.V.; Kashcheeva, P.V.; Shchukina, N.V.; Ivanov, V.K. [Russian Ministry of Health, Federal State Institution, Medical Radiological Research Center, Obninsk, Kaluga Region (Russian Federation)

    2015-03-15

    This paper presents the results of a retrospective cohort study of cancer incidence and mortality among emergency workers of the Chernobyl accident, for the follow-up period 1992-2009. The cohort selected for analysis consists of 67,568 emergency workers who worked in the Chernobyl exclusion zone in 1986-1987. External radiation whole-body absorbed dose varied from 0.0001 gray (Gy) to 1.24 Gy, with a median of 0.102 Gy. Over the follow-up period 1992-2009, a total of 4,002 solid cancers of different sites were identified as the result of annual compulsory health examination, and a total of 2,442 deaths from all solid cancers in the study cohort were reported. Poisson regression was applied for the analysis of cancer incidence and mortality. The analysis of the standardized incidence ratio (SIR) has shown a statistically significant increase in cancer incidence in the cohort as compared with baseline cancer incidence among males of Russia. The average excess over the entire follow-up period is 18 % [SIR = 1.18, 95 % confidence interval (CI) 1.15; 1.22]. In contrast, however, no increase in the mortality from all cancers among the emergency workers as compared to the baseline mortality in Russian men was found. Values of excess relative risk of cancer incidence and mortality per 1 Gy (ERR Gy{sup -1}) are 0.47 (95 % CI 0.03; 0.96, p value = 0.034) and 0.58 (95 % CI 0.002; 1.25, p value = 0.049), respectively. These values are statistically significant. (orig.)

  1. Radiation tolerance of the cervical spinal cord: incidence and dose-volume relationship of symptomatic and asymptomatic late effects following high dose irradiation of paraspinal tumors

    International Nuclear Information System (INIS)

    Liu, Mitchell C.C.; Munzenrider, John E.; Finkelstein, Dianne; Liebsch, Norbert; Adams, Judy; Hug, Eugen B.

    1997-01-01

    Purpose: Low grade chordomas and chondrosarcomas require high radiation doses for effective, lasting tumor control. Fractionated, 3-D planned, conformal proton radiation therapy has been used for lesions along the base of skull and spine to deliver high target doses, while respecting constraints of critical, normal tissues. In this study, we sought to determine the incidence of myelopathy after high dose radiotherapy to the cervical spine and investigated the influence of various treatment parameters, including dose-volume relationship. Methods and Materials: Between December 1980 and March 1996, 78 patients were treated at the Massachusetts General Hospital and Harvard Cyclotron Laboratory for primary or recurrent chordomas and chondrosarcomas of the cervical spine using combined proton and photon radiation therapy. In general, the tumor dose given was between 64.5 to 79.2 CGE (Cobalt Gray Equivalent). The guidelines for maximum permissible doses to spinal cord were: ≤ 64 CGE to the spinal cord surface and ≤ 53 CGE to the spinal cord center. Dose volume histograms of the spinal cord were analyzed to investigate a possible dose and volume relationship. Results: With a mean follow-up period of 46.6 months (range: 3 - 157 months), 4 of 78 patients (5.1%) developed high-grade (RTOG Grade 3 and 4) late toxicity: 3 patients (3.8%) experienced sensory deficits without motor deficits, none had any limitations of daily activities. One patient (1.2%) developed motor deficit with loss of motor function of one upper extremity. The only patient, who developed permanent motor damage had received additional prior radiation treatment and therefore received a cumulative spinal cord dose higher than the treatment guidelines. No patient treated within the guidelines experienced any motor impairment. Six patients (7.7%) experienced transient Lhermitt's syndrome and 1 patient (1.2%) developed asymptomatic radiographic MR findings only. Time to onset of symptoms of radiographic

  2. Performance study of monochromatic synchrotron X-ray computed tomography using a linear array detector

    Energy Technology Data Exchange (ETDEWEB)

    Kazama, Masahiro; Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Akiba, Masahiro; Yuasa, Tetsuya; Hyodo, Kazuyuki; Ando, Masami; Akatsuka, Takao

    1997-09-01

    Monochromatic x-ray computed tomography (CT) using synchrotron radiation (SR) is being developed for detection of non-radioactive contrast materials at low concentration for application in clinical diagnosis. A new SR-CT system with improved contrast resolution, was constructed using a linear array detector which provides wide dynamic ranges and a double monochromator. The performance of this system was evaluated in a phantom and a rat model of brain ischemia. This system consists of a silicon (111) double crystal monochromator, an x-ray shutter, an ionization chamber, x-ray slits, a scanning table for the target organ, and an x-ray linear array detector. The research was carried out at the BLNE-5A bending magnet beam line of the Tristan Accumulation Ring in KEK, Japan. In this experiment, the reconstructed image of the spatial-resolution phantom clearly showed the 1 mm holes. At 1 mm slice thickness, the above K-edge image of the phantom showed contrast resolution at the concentration of 200 {mu}g/ml iodine-based contrast materials whereas the K-edge energy subtraction image showed contrast resolution at the concentration of 500 {mu}g/ml contrast materials. The cerebral arteries filled with iodine microspheres were clearly revealed, and the ischemic regions at the right temporal lobe and frontal lobe were depicted as non-vascular regions. The measured minimal detectable concentration of iodine on the above K-edge image is about 6 times higher than the expected value of 35.3 {mu}g/ml because of the high dark current of this detector. Thus, the use of a CCD detector which is cooled by liquid nitrogen to improve the dynamic range of the detector, is being under construction. (author)

  3. Updated estimates of the proportion of childhood leukaemia incidence in Great Britain that may be caused by natural background ionising radiation

    International Nuclear Information System (INIS)

    Little, Mark P; Wakeford, Richard; Kendall, Gerald M

    2009-01-01

    The aetiology of childhood leukaemia remains generally unknown, although exposure to moderate and high levels of ionising radiation, such as was experienced during the atomic bombings of Japan or from radiotherapy, is an established cause. Risk models based primarily upon studies of the Japanese A-bomb survivors imply that low-level exposure to ionising radiation, including to ubiquitous natural background radiation, also raises the risk of childhood leukaemia. In a recent paper (Wakeford et al 2009 Leukaemia 23 770-6) we estimated the proportion of childhood leukaemia incidence in Great Britain attributable to natural background radiation to be about 20%. In this paper we employ the two sets of published leukaemia risk models used previously, but use recently published revised estimates of natural background radiation doses received by the red bone marrow of British children to update the previous results. Using the newer dosimetry we calculate that the best estimate of the proportion of cases of childhood leukaemia in Great Britain predicted to be attributable to this source of exposure is 15-20%, although the uncertainty associated with certain stages in the calculation (e.g. the nature of the transfer of risk between populations and the pertinent dose received from naturally occurring alpha-particle-emitting radionuclides) is significant. The slightly lower attributable proportions compared with those previously derived by Wakeford et al (Leukaemia 2009 23 770-6) are largely due to the lower doses (and in particular lower high LET doses) for the first year of life.

  4. Perceived Incidence and Importance of Lay-Ideas on Ionizing Radiation: Results of a Delphi-Study among Radiation-Experts.

    Science.gov (United States)

    Eijkelhof, H. M. C.; And Others

    1990-01-01

    Described are lay-ideas which may exist about ionizing radiation, the importance of these ideas for risk management, and the relationships between various lay-ideas. Lay-ideas were used to gain a better insight into the problems of learning about ionizing radiation and to construct appropriate teaching materials and strategies. (KR)

  5. Biodosimetry: Medicine, Science, and Systems to Support the Medical Decision-Maker Following a Large Scale Nuclear or Radiation Incident

    International Nuclear Information System (INIS)

    Coleman, C. Norman; Koerner, John F.

    2016-01-01

    The public health and medical response to a radiological or nuclear incident requires the capability to sort, assess, treat, triage and to ultimately discharge, refer or transport people to their next step in medical care. The size of the incident and scarcity of resources at the location of each medical decision point will determine how patients are triaged and treated. This will be a rapidly evolving situation impacting medical responders at regional, national and international levels. As capabilities, diagnostics and medical countermeasures improve, a dynamic system-based approach is needed to plan for and manage the incident, and to adapt effectively in real time. In that the concepts and terms can be unfamiliar and possibly confusing, resources and a concept of operations must be considered well in advance. An essential underlying tenet is that medical evaluation and care will be managed by health-care professionals with biodosimetry assays providing critical supporting data. (authors)

  6. Comment on “Collision monochromatization in e^{+}e^{-} colliders”

    Directory of Open Access Journals (Sweden)

    D. Shatilov

    2018-02-01

    Full Text Available Bogomyagkov and Levichev [Phys. Rev. Accel. Beams 20, 051001 (2017PRABCJ2469-988810.1103/PhysRevAccelBeams.20.051001] have recently reported on monochromatization in collision schemes with crossing angle. From their results, in particular, it may seem that: (1 horizontal dispersion at the IP can provide monochromatization factor Λ≫1 while retaining Piwinski angle ϕ>1, (2 production rate in such a scheme for FCC-ee at 62.5 GeV can be larger than that in the nominal crab waist collision, and (3 strong rf focusing can be used for monochromatization purposes. We demonstrate here that the first two statements are not correct, and the last one is very doubtful.

  7. Monochromatic computed tomography of the human brain using synchrotron x rays: Technical feasibility

    International Nuclear Information System (INIS)

    Nachaliel, E.; Dilmanian, F.A.; Garrett, R.F.; Thomlinson, W.C.; Chapman, L.D.; Gmuer, N.F.; Lazarz, N.M.; Moulin, H.R.; Rivers, M.L.; Rarback, H.; Stefan, P.M.; Spanne, P.; Luke, P.N.; Pehl, R.; Thompson, A.C.; Miller, M.

    1991-01-01

    A monochromatic computed tomography (CT) scanner is being developed at the X17 superconducting wiggler beamline at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, to image the human head and neck. The system configuration is one of a horizontal fan beam and an upright seated rotating subject. The purpose of the project are to demonstrate improvement in the image contrast and in the image quantitative accuracy that can be obtained in monochromatic CT and to apply the system to specific clinical research programs in neuroradiology. This paper describes the first phantom studies carried out with a prototype system, using the dual photon absorptiometry (DPA) method at energies of 20 and 39 Kev. The results show that improvements in image contrast and quantitative accuracy are possible with monochromatic DPA CT. Estimates of the clinical performance of the planned CT system are made on the basis of these initial results

  8. Estimation of incident solar radiation on the roof of the cultural and sports university centre of the Foundation University Los Libertadores

    International Nuclear Information System (INIS)

    Jiménez, S A; Carrillo, V M; Rátiva, L C

    2016-01-01

    This document shows the estimate of the total solar irradiance incident for the set of solar collectors to be located on the roof of cultural and sports university centre (CSUC) of the Foundation University Los Libertadores (FULL) in Bogotá, Colombia, and they will be part of the climate control system of the pool built inside. The calculation was based on experimental data of global solar radiation on the horizontal surface on March, July, October, November and December, through the three most commonly models used to determine the total solar radiation on tilted surfaces: isotropic sky, HDKR and Perez. The results show differences of less than 5% between the values calculated by the three models for December, the month with lower irradiance. For this month, reductions up to 15% and 19% were observed in the estimated irradiance, relative to those obtained on a horizontal surface on a surface under ideal orientation and inclination, respectively. (paper)

  9. Estimation of incident solar radiation on the roof of the cultural and sports university centre of the Foundation University Los Libertadores

    Science.gov (United States)

    Jiménez, S. A.; Carrillo, V. M.; Rátiva, L. C.

    2016-02-01

    This document shows the estimate of the total solar irradiance incident for the set of solar collectors to be located on the roof of cultural and sports university centre (CSUC) of the Foundation University Los Libertadores (FULL) in Bogotá, Colombia, and they will be part of the climate control system of the pool built inside. The calculation was based on experimental data of global solar radiation on the horizontal surface on March, July, October, November and December, through the three most commonly models used to determine the total solar radiation on tilted surfaces: isotropic sky, HDKR and Perez. The results show differences of less than 5% between the values calculated by the three models for December, the month with lower irradiance. For this month, reductions up to 15% and 19% were observed in the estimated irradiance, relative to those obtained on a horizontal surface on a surface under ideal orientation and inclination, respectively.

  10. Radiation background and the incidence of cataracta among the population groups of the Far North. [Radioisotopes: sup(210)Pb; sup(210)Po; sup(137)Cs; sup(90)Sr

    Energy Technology Data Exchange (ETDEWEB)

    Nizhnikov, A I; Miretskij, G I; Ramzaev, P V; Troitskaya, M N [Nauchno-Issledovatel' skij Inst. Radiatsionnoj Gigieny, Leningrad (USSR)

    1984-07-01

    The incidence of senile cataracta in the residents of the Far North regions and the newcomers differing in the effective equivalent dose due to all types of radiation (except radon decay products for lungs) approximately by 2 times, is studied. The data on the age and sex composition of population with initially established diagnosis of senile cataracta are presented. Lens injury is found to occur earlier in men than in women (the difference is about 5 years). Cataracta frequency increases with age. In the native population of the Far North at 65 and older, cataracta takes place by 2-3 times oftener. Investigations are continued to specify the role of the radiation factor in the integrated effect of the environment on the formation of cataracta in population.

  11. Effect of the time spent by the photon in the absorbed state on the time-dependent transfer of radiation

    International Nuclear Information System (INIS)

    Rao, D.M.; Rangarajan, K.E.; Peraiah, A.

    1990-01-01

    The time-dependent transfer equation is derived for a two-level atomic model which takes both bound-bound and bound-free transitions into account. A numerical scheme is proposed for solving the monochromatic time-dependent transfer equation when the time spent by the photon in the absorbed state is significant. The method can be easily extended to solve the problem of time-dependent line formation of the bound-free continuum. It is used here to study three types of boundary conditions of the incident radiation incident on a scattering atmosphere. The quantitative results show that the relaxation of the radiation field depends on the optical depth of the medium and on the ray's angle of emergence. 21 refs

  12. Inelastic neutron scattering experiments with the monochromatic imaging mode of the RITA-II spectrometer

    International Nuclear Information System (INIS)

    Bahl, C.R.H.; Lefmann, K.; Abrahamsen, A.B.; Ronnow, H.M.; Saxild, F.; Jensen, T.B.S.; Udby, L.; Andersen, N.H.; Christensen, N.B.; Jakobsen, H.S.; Larsen, T.; Haefliger, P.S.; Streule, S.; Niedermayer, Ch.

    2006-01-01

    Recently a monochromatic multiple data taking mode has been demonstrated for diffraction experiments using a RITA type cold neutron spectrometer with a multi-bladed analyser and a position-sensitive detector. Here, we show how this mode can be used in combination with a flexible radial collimator to perform real inelastic neutron scattering experiments. We present the results from inelastic powder, single crystal dispersion and single crystal constant energy mapping experiments. The advantages and complications of performing these experiments are discussed along with a comparison between the imaging mode and the traditional monochromatic focussing mode

  13. Inelastic neutron scattering experiments with the monochromatic imaging mode of the RITA-II spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bahl, C.R.H. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark) and Department of Physics, Technical University of Denmark, DK-2800 Lyngby (Denmark)]. E-mail: christian.bahl@risoe.dk; Lefmann, K. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)]. E-mail: kim.lefmann@risoe.dk; Abrahamsen, A.B. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Ronnow, H.M. [Laboratory for Neutron Scattering, Paul Scherrer Institute, CH-5232 Villigen (Switzerland); Saxild, F. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Jensen, T.B.S. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Udby, L. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Andersen, N.H. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Christensen, N.B. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Laboratory for Neutron Scattering, Paul Scherrer Institute, CH-5232 Villigen (Switzerland); Jakobsen, H.S. [Niels Bohr Institute for Astronomy, Physics and Geophysics, University of Copenhagen, DK-2100 Copenhagen (Denmark); Larsen, T. [Niels Bohr Institute for Astronomy, Physics and Geophysics, University of Copenhagen, DK-2100 Copenhagen (Denmark); Haefliger, P.S. [Laboratory for Neutron Scattering, Paul Scherrer Institute, CH-5232 Villigen (Switzerland); Streule, S.; Niedermayer, Ch. [Laboratory for Neutron Scattering, Paul Scherrer Institute, CH-5232 Villigen (Switzerland)

    2006-05-15

    Recently a monochromatic multiple data taking mode has been demonstrated for diffraction experiments using a RITA type cold neutron spectrometer with a multi-bladed analyser and a position-sensitive detector. Here, we show how this mode can be used in combination with a flexible radial collimator to perform real inelastic neutron scattering experiments. We present the results from inelastic powder, single crystal dispersion and single crystal constant energy mapping experiments. The advantages and complications of performing these experiments are discussed along with a comparison between the imaging mode and the traditional monochromatic focussing mode.

  14. Monochromatic Minibeams Radiotherapy: From Healthy Tissue-Sparing Effect Studies Toward First Experimental Glioma Bearing Rats Therapy

    International Nuclear Information System (INIS)

    Deman, Pierre; Vautrin, Mathias; Edouard, Magali; Stupar, Vasile; Bobyk, Laure; Farion, Régine; Elleaume, Hélène; Rémy, Chantal; Barbier, Emmanuel L.; Estève, François; Adam, Jean-François

    2012-01-01

    Purpose: The purpose of this study was to evaluate high-dose single fraction delivered with monochromatic X-rays minibeams for the radiotherapy of primary brain tumors in rats. Methods and Materials: Two groups of healthy rats were irradiated with one anteroposterior minibeam incidence (four minibeams, 123 Gy prescribed dose at 1 cm depth in the brain) or two interleaved incidences (54 Gy prescribed dose in a 5 × 5 × 4.8 mm 3 volume centered in the right hemisphere), respectively. Magnetic resonance imaging (MRI) follow-up was performed over 1 year. T2-weighted (T2w) images, apparent diffusion coefficient (ADC), and blood vessel permeability maps were acquired. F98 tumor bearing rats were also irradiated with interleaved minibeams to achieve a homogeneous dose of 54 Gy delivered to an 8 × 8 × 7.8 mm 3 volume centered on the tumor. Anatomic and functional MRI follow-up was performed every 10 days after irradiation. T2w images, ADC, and perfusion maps were acquired. Results: All healthy rats were euthanized 1 year after irradiation without any clinical alteration visible by simple examination. T2w and ADC measurements remain stable for the single incidence irradiation group. Localized Gd-DOTA permeability, however, was observed 9 months after irradiation for the interleaved incidences group. The survival time of irradiated glioma bearing rats was significantly longer than that of untreated animals (49 ± 12.5 days versus 23.3 ± 2 days, p < 0.001). The tumoral cerebral blood flow and blood volume tend to decrease after irradiation. Conclusions: This study demonstrates the sparing effect of minibeams on healthy tissue. The increased life span achieved for irradiated glioma bearing rats was similar to the one obtained with other radiotherapy techniques. This experimental tumor therapy study shows the feasibility of using X-ray minibeams with high doses in brain tumor radiotherapy.

  15. Monochromatic Minibeams Radiotherapy: From Healthy Tissue-Sparing Effect Studies Toward First Experimental Glioma Bearing Rats Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Deman, Pierre [INSERM, Grenoble (France); Universite Joseph Fourier, Institut des Neurosciences, Grenoble (France); European Synchrotron Radiation Facility, Grenoble (France); Vautrin, Mathias [INSERM, Grenoble (France); Universite Joseph Fourier, Institut des Neurosciences, Grenoble (France); European Synchrotron Radiation Facility, Grenoble (France); DOSIsoft, Cachan (France); Edouard, Magali [INSERM, Grenoble (France); Universite Joseph Fourier, Institut des Neurosciences, Grenoble (France); European Synchrotron Radiation Facility, Grenoble (France); Stupar, Vasile [INSERM, Grenoble (France); Universite Joseph Fourier, Institut des Neurosciences, Grenoble (France); Bobyk, Laure; Farion, Regine [INSERM, Grenoble (France); Universite Joseph Fourier, Institut des Neurosciences, Grenoble (France); European Synchrotron Radiation Facility, Grenoble (France); Elleaume, Helene [INSERM, Grenoble (France); Universite Joseph Fourier, Institut des Neurosciences, Grenoble (France); European Synchrotron Radiation Facility, Grenoble (France); Grenoble University Hospital, Grenoble (France); Remy, Chantal; Barbier, Emmanuel L. [INSERM, Grenoble (France); Universite Joseph Fourier, Institut des Neurosciences, Grenoble (France); Esteve, Francois [INSERM, Grenoble (France); Universite Joseph Fourier, Institut des Neurosciences, Grenoble (France); European Synchrotron Radiation Facility, Grenoble (France); Grenoble University Hospital, Grenoble (France); Adam, Jean-Francois, E-mail: adam@esrf.fr [INSERM, Grenoble (France); Universite Joseph Fourier, Institut des Neurosciences, Grenoble (France); European Synchrotron Radiation Facility, Grenoble (France); Grenoble University Hospital, Grenoble (France)

    2012-03-15

    Purpose: The purpose of this study was to evaluate high-dose single fraction delivered with monochromatic X-rays minibeams for the radiotherapy of primary brain tumors in rats. Methods and Materials: Two groups of healthy rats were irradiated with one anteroposterior minibeam incidence (four minibeams, 123 Gy prescribed dose at 1 cm depth in the brain) or two interleaved incidences (54 Gy prescribed dose in a 5 Multiplication-Sign 5 Multiplication-Sign 4.8 mm{sup 3} volume centered in the right hemisphere), respectively. Magnetic resonance imaging (MRI) follow-up was performed over 1 year. T2-weighted (T2w) images, apparent diffusion coefficient (ADC), and blood vessel permeability maps were acquired. F98 tumor bearing rats were also irradiated with interleaved minibeams to achieve a homogeneous dose of 54 Gy delivered to an 8 Multiplication-Sign 8 Multiplication-Sign 7.8 mm{sup 3} volume centered on the tumor. Anatomic and functional MRI follow-up was performed every 10 days after irradiation. T2w images, ADC, and perfusion maps were acquired. Results: All healthy rats were euthanized 1 year after irradiation without any clinical alteration visible by simple examination. T2w and ADC measurements remain stable for the single incidence irradiation group. Localized Gd-DOTA permeability, however, was observed 9 months after irradiation for the interleaved incidences group. The survival time of irradiated glioma bearing rats was significantly longer than that of untreated animals (49 {+-} 12.5 days versus 23.3 {+-} 2 days, p < 0.001). The tumoral cerebral blood flow and blood volume tend to decrease after irradiation. Conclusions: This study demonstrates the sparing effect of minibeams on healthy tissue. The increased life span achieved for irradiated glioma bearing rats was similar to the one obtained with other radiotherapy techniques. This experimental tumor therapy study shows the feasibility of using X-ray minibeams with high doses in brain tumor radiotherapy.

  16. Asymmetric rotator as a detector of monochromatic gravitational waves

    International Nuclear Information System (INIS)

    Gliner, Eh.B.; Mitrofanov, I.G.

    1979-01-01

    The interaction between a rotating asymmetric (principal moments of inertia are different) body with a gravitational wave is considered. A resonance rotational detector of monocrhomatic gravitational waves is proposed in which the turning due to the incident wave and the rotation which ensures resonance between the detector and wave correspond to different degrees of freedom. This significantly facilitates the creation of such detectors. The interference due to the gradient of the gravitational acceleration of the Earth and to rotation of the detector as a whole is estimated

  17. Radiation

    International Nuclear Information System (INIS)

    2013-01-01

    The chapter one presents the composition of matter and atomic theory; matter structure; transitions; origin of radiation; radioactivity; nuclear radiation; interactions in decay processes; radiation produced by the interaction of radiation with matter

  18. 2011 Japanese Nuclear Incident

    Science.gov (United States)

    EPA’s RadNet system monitored the environmental radiation levels in the United States and parts of the Pacific following the Japanese Nuclear Incident. Learn about EPA’s response and view historical laboratory data and news releases.

  19. Emergency preparedness incident response and radiation monitoring in Finland. Annual report 1998; Valmiustapahtumat ja valtakunnallinen saeteilyvalvonta. Vuosiraportti 1998

    Energy Technology Data Exchange (ETDEWEB)

    Ristonmaa, S. [ed.

    1999-03-01

    The Radiation and Nuclear Safety Authority (STUK) publishes annually a report about STUK's preparedness measures. The report describes notifications received by STUK's on duty system and further measures carried out after receiving a message. In addition, the emergence exercises STUK participated in during the year are described. The radiation situation in Finland is continuously monitored. STUK is the authority who carries out a wide range of environmental measurements, sampling and sensitive laboratory analyses. The measurement results are presented in the form of tables and graphically. (editor)

  20. Emergency preparedness incident response and radiation monitoring in Finland. Annual report 1999; Valmiustapahtumat ja saeteilyvalvonta. Vuosiraportti 1999

    Energy Technology Data Exchange (ETDEWEB)

    Ristonmaa, S. [ed.

    2000-04-01

    The Radiation and Nuclear Safety Authority (STUK) publishes annually a report about STUK's preparedness measures. The report describes notifications received by STUK's on duty system and further measures carried out after receiving a message. In addition, the emergence exercises STUK participated in during the year are described. The radiation situation in Finland is continuously monitored. STUK is the authority who carries out a wide range of environmental measurements, sampling and sensitive laboratory analyses. The measurement results are presented in the form of tables and graphically. (editor)

  1. Mitotic effects of monochromatic ultraviolet radiation at 225, 265, and 280 nm on eleven stages of the cell cycle of the grasshopper neuroblast in culture. II. Changes in progression rate and cell sequence between the stage irradiated and nuclear membrane breakdown

    International Nuclear Information System (INIS)

    Carlson, J.G.

    1976-01-01

    Portions of embryos of the grasshopper, Chortophaga viridifasciata (DeGeer), were cultured in hanging drops under quartz cover slips. Immediately after exposure to 225, 265, or 280 nm radiation, microscope observations at 38 0 C were begun. The morphologically identified stage and the time after treatment of selected neuroblasts were recorded at short-time intervals until prometaphase was reached. Mitotic retardation induced by irradiation of prereplication stages (metaphase, anaphase, or early telophase) or S phase (middle or late telophase, interphase, or very early prophase) is greatest in postreplication stages (early, middle, and late prophase) and absent or minimal in stages morphologically identified as parts of S phase. Ultraviolet irradiation superimposes on the normal diversity of progression rates an additional variation factor, so that cells do not necessarily reach prometaphase in the order of their sequence at the time of treatment. This suggests the need for caution in ascribing particular radiosensitivities to substages of limited duration on the basis of the order in which they attain a subsequent stage

  2. Cancer incidence among a cohort of subjects exposed to low-dose rate chronic radiation exposure in utero and after birth in the techa riverbank villages

    International Nuclear Information System (INIS)

    Ostroumova, E.V.; Akleyev, A.V.; Akleyev, A.V.; Hall, P.

    2003-01-01

    As a result of releases of liquid radioactive waste by the Mayak Production Association (PA) into the Techa River since 1949 till 1956 the population of the Riverside villages was exposed to a protracted effect of combined (external and internal) radiation. The 1-st-generation offspring of exposed residents born on 01.01.1950 and later were exposed both in utero and after birth. In all, 46 cancer cases, including 4 cases of leukemia, were registered among the study cohort members numbering 7,890 subjects born in the Techa Riverside villages in the Chelyabinsk province over the period since 1950 till 1998. No significant differences were noted in cancer incidence rates between men and women. Cancer incidence in the offspring's cohort was by 30-35% higher compared with the unexposed population of the USSR and Russia, the differences, however, are statistically insignificant. No influence of the parents total gonadal dose on cancer development in offspring was observed. The positive dose-effect dependence of cancer incidence on both antenatal and postnatal exposure was traced

  3. The Use of Categorized Time-Trend Reporting of Radiation Oncology Incidents: A Proactive Analytical Approach to Improving Quality and Safety Over Time

    International Nuclear Information System (INIS)

    Arnold, Anthony; Delaney, Geoff P.; Cassapi, Lynette; Barton, Michael

    2010-01-01

    Purpose: Radiotherapy is a common treatment for cancer patients. Although incidence of error is low, errors can be severe or affect significant numbers of patients. In addition, errors will often not manifest until long periods after treatment. This study describes the development of an incident reporting tool that allows categorical analysis and time trend reporting, covering first 3 years of use. Methods and Materials: A radiotherapy-specific incident analysis system was established. Staff members were encouraged to report actual errors and near-miss events detected at prescription, simulation, planning, or treatment phases of radiotherapy delivery. Trend reporting was reviewed monthly. Results: Reports were analyzed for the first 3 years of operation (May 2004-2007). A total of 688 reports was received during the study period. The actual error rate was 0.2% per treatment episode. During the study period, the actual error rates reduced significantly from 1% per year to 0.3% per year (p < 0.001), as did the total event report rates (p < 0.0001). There were 3.5 times as many near misses reported compared with actual errors. Conclusions: This system has allowed real-time analysis of events within a radiation oncology department to a reduced error rate through focus on learning and prevention from the near-miss reports. Plans are underway to develop this reporting tool for Australia and New Zealand.

  4. The use of Co2+ for crystallization and structure determination, using a conventional monochromatic X-ray source, of flax rust avirulence protein

    International Nuclear Information System (INIS)

    Gunčar, Gregor; Wang, Ching-I A.; Forwood, Jade K.; Teh, Trazel; Catanzariti, Ann-Maree; Ellis, Jeffrey G.; Dodds, Peter N.; Kobe, Boštjan

    2007-01-01

    It is demonstrated that anomalous diffraction based on the signal from a cobalt ion measured on a conventional monochromatic X-ray source can be used to determine the structure of a protein with a novel fold (M. lini avirulence protein AvrL567-A). The approach could be applicable to many metal-binding proteins, particularly when synchrotron radiation is not readily available. Metal-binding sites are ubiquitous in proteins and can be readily utilized for phasing. It is shown that a protein crystal structure can be solved using single-wavelength anomalous diffraction based on the anomalous signal of a cobalt ion measured on a conventional monochromatic X-ray source. The unique absorption edge of cobalt (1.61 Å) is compatible with the Cu Kα wavelength (1.54 Å) commonly available in macromolecular crystallography laboratories. This approach was applied to the determination of the structure of Melampsora lini avirulence protein AvrL567-A, a protein with a novel fold from the fungal pathogen flax rust that induces plant disease resistance in flax plants. This approach using cobalt ions may be applicable to all cobalt-binding proteins and may be advantageous when synchrotron radiation is not readily available

  5. Periprosthetic Artifact Reduction Using Virtual Monochromatic Imaging Derived From Gemstone Dual-Energy Computed Tomography and Dedicated Software.

    Science.gov (United States)

    Reynoso, Exequiel; Capunay, Carlos; Rasumoff, Alejandro; Vallejos, Javier; Carpio, Jimena; Lago, Karen; Carrascosa, Patricia

    2016-01-01

    The aim of this study was to explore the usefulness of combined virtual monochromatic imaging and metal artifact reduction software (MARS) for the evaluation of musculoskeletal periprosthetic tissue. Measurements were performed in periprosthetic and remote regions in 80 patients using a high-definition scanner. Polychromatic images with and without MARS and virtual monochromatic images were obtained. Periprosthetic polychromatic imaging (PI) showed significant differences compared with remote areas among the 3 tissues explored (P remote tissues using monochromatic imaging with MARS (P = 0.053 bone, P = 0.32 soft tissue, and P = 0.13 fat). However, such differences were significant using PI with MARS among bone (P = 0.005) and fat (P = 0.02) tissues. All periprosthetic areas were noninterpretable using PI, compared with 11 (9%) using monochromatic imaging. The combined use of virtual monochromatic imaging and MARS reduced periprosthetic artifacts, achieving attenuation levels comparable to implant-free tissue.

  6. Response of TAPS to monochromatic photons with energies between 45 and 790 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Gabler, A.R. (II. Physikalisches Institut, Universitaet Giessen, D-35392 Giessen (Germany)); Doering, W. (II. Physikalisches Institut, Universitaet Giessen, D-35392 Giessen (Germany)); Fuchs, M. (II. Physikalisches Institut, Universitaet Giessen, D-35392 Giessen (Germany)); Krusche, B. (II. Physikalisches Institut, Universitaet Giessen, D-35392 Giessen (Germany)); Metag, V. (II. Physikalisches Institut, Universitaet Giessen, D-35392 Giessen (Germany)); Novotny, R. (II. Physikalisches Institut, Universitaet Giessen, D-35392 Giessen (Germany)); Roebig-Landau, M. (II. Physikalisches Institut, Universitaet Giessen, D-35392 Giessen (Germany)); Stroeher, H. (II. Physikalisches Institut, Universitaet Giessen, D-35392 Giessen (Germany)); Tries, V. (II. Physikalisches Institut, Universitaet Giessen, D-35392 Giessen (Germany)); Molenaar, C. (Kernfysisch Versneller Instituut, Groningen (Netherlands)); Loehner, H. (Kernfysisch Versneller Instituut, Groningen (Netherlands)); Van Pol, J.H

    1994-07-15

    The Two Arm Photon Spectrometer TAPS - comprising 384 plastic-BaF[sub 2] scintillator telescopes - was tested with monochromatic photons in the energy range between 45 and 790 MeV. The energy resolution for a collimated photon beam hitting the central detector module was determined to [sigma]/E=0.59%xE[sup -1/2][sub [gamma

  7. Pustular Palmoplantar Psoriasis Successfully Treated with Nb-UVB Monochromatic Excimer Light: A Case-Report

    Directory of Open Access Journals (Sweden)

    Serena Gianfaldoni

    2017-07-01

    Full Text Available Barber’s palmoplantar pustulosis (PPP is a form of localised pustular psoriasis, affecting the palmar and plantar surfaces. It is a chronic disease, with a deep impact on the patients’ quality of life. The Authors discuss a case of Baber Psoriasis successfully treated with monochromatic excimer light.

  8. Inelastic neutron scattering experiments with the monochromatic imaging mode of the RITA-II spectrometer

    DEFF Research Database (Denmark)

    Bahl, Christian Robert Haffenden; Lefmann, Kim; Abrahamsen, Asger Bech

    2006-01-01

    Recently a monochromatic multiple data taking mode has been demonstrated for diffraction experiments using a RITA type cold neutron spectrometer with a multi-bladed analyser and a position-sensitive detector. Here, we show how this mode can be used in combination with a flexible radial collimator...

  9. Nonlinear behavior of a monochromatic wave in a one-dimensional Vlasov plasma

    International Nuclear Information System (INIS)

    Shoucri, M.M.; Gagne, R.R.J.

    1978-01-01

    The nonlinear evolution of a monochromatic wave in a one-dimensional Vlasov plasma is studied numerically. The numerical results are carried out far enough in time for phase mixing to dominate the asymptotic state of the system. A qualitative comparison with previously reported simulations is given

  10. Wave-flume experiments of soft-rock cliff erosion under monochromatic waves

    Science.gov (United States)

    Regard, Vincent; Astruc, Dominique; Caplain, Bastien

    2017-04-01

    We investigate how cliffs erode under wave attack. Rocky coast erosion works through cycles, each one corresponding to three successive phases: (i) notch creation at cliff toe by mechanical action of waves, (ii) cliff fracturation leading to collapse, and (iii) evacuation of scree aprons by waves and currents. We performed experiments in a 5m x 14cm x 25cm wave flume (15 cm water depth) to investigate how waves are eroding a rocky coast. The cliff is made of wet sand and models a relatively soft rock. We used 3 different grain size (D50 = 0.28-0.41-0.48 mm), changing the cliff rheology. Waves are monochromatic; their height and period differ for the various experiments. Actual wave parameters are estimated by capacitive probes located offshore. The experiments are monitored by two video cameras both on the side and above the flume. Pictures are taken at a rate of 1Hz during the first 4h and then the rate is decreased to 0.1Hz till the end of experiment (about 1 day). The monitoring ensure a confident characterization of experiments in terms of waves (surf similarity parameter ξ and the incident wave energy flux F) and in terms of sediment (Dean number Ω and Shields number θb at breakers). Experiments begin by an initial phase of quick cliff retreat. Then the system evolves with slower cliff retreat. We focus on bottom morphology which we characterize in function of wave forcing (ξ, F). We show that the bottom morphology mainly depends on ξ. For our reference sediment (Dm = 0.41 mm), we observed: (i) surging breakers on a steep terrace (type T1) for ξ > 0.65; (ii)collapsing breakers on a bared profile attached to the inner platform (type T2) for 0.55< ξ <0.6; (iii) spilling breakers on gentle terrace (type T3) for F < 1.3 W/m and 0.55< ξ <0.6. Another bottom morphology, type T4, displays two sub-systems, an outer system with a double-bar profile where breaking waves are plunging, and an inner system with a T1, T2 or T3 profile. Some of these bottom

  11. Incidence of radiation-induced Graves' disease in patients treated with radioiodine for thyroid autonomy before and after introduction of a high-sensitivity TSH receptor antibody assay

    International Nuclear Information System (INIS)

    Dunkelmann, Simone; Wolf, Ricarda; Koch, Annedore; Kittner, Christian; Groth, Peter; Schuemichen, Carl

    2004-01-01

    Autoimmune hyperthyroidism may occur several months after radioiodine therapy (RIT) for functional thyroid autonomy. Exacerbation of pre-existing subclinical Graves' disease (GD) has been held responsible for this phenomenon. Determination of TSH receptor antibody using solubilised porcine epithelial cell membranes is insensitive and may have failed to diagnose GD in these patients before RIT. Following the introduction of a more sensitive assay, using the human TSH receptor as an antigen, it has been expected that the incidence of radiation-induced GD after RIT for functional thyroid autonomy will be reduced. In a first group of 1,428 patients treated between November 1993 and March 1997 (group I) we used the porcine TRAb assay to exclude GD, while in a second group comprising 1,408 patients treated between January 2000 and December 2001 (group II), GD was excluded using the human TRAb assay. A matched control group of 231 patients was derived from group II. In group I a total of 15 (1.05%) patients developed obvious or suspected radiation-induced GD, while in group II 17 (1.2%) did so; the interval until development of GD was 8.4 and 8.8 months, respectively, after RIT. Serum anti-thyroid peroxidase levels before RIT were elevated in 36.4% of group I patients and 47.1% of group II patients, but in only 5.6% of the control group. Other non-specific signs of mild immunopathy of the thyroid were seen retrospectively in 73.3%, 64.7% and 16.0% of the patients in these three groups, respectively. In conclusion, the introduction of a high-sensitivity TRAb assay did not reduce the incidence of autoimmune hyperthyroidism occurring late after RIT for functional thyroid autonomy, but mild immunopathy of the thyroid is seen more frequently in these patients and seems to be a predisposing factor in the development of radiation-induced GD. (orig.)

  12. Damage to adenosine-triphosphate induced by monochromatic X rays around the K shell absorption edge of phosphorus

    International Nuclear Information System (INIS)

    Watanabe, Ritsuko; Ishikawa, Mitsuo; Takakura, Kaoru; Kobayashi, Katsumi

    1992-01-01

    Adenosine-triphosphate (ATP) is well known to have an important role in the energy metabolism in biological systems. The purpose of this study is to clarify the radiation effects on ATP specific to inner shell ionization. ATP, in concentrated aqueous solution, was irradiated with monochromatic X rays having energies of the resonance absorption peak of the phosphorus K shell, 2.153 keV, and slightly below and above the peak, 2.145 keV and 2.160 keV, selected from synchrotron radiation. Adenine, Adenosine 5'monophosphate (5'AMP) and Adenosine 5'diphosphate (5'ADP) were obtained as radioproducts by the method of high performance liquid chromatography (HPLC). G values of these products were calculated on the basis of the absorbed energy. When the ATP solution of 0.282 mol/l was irradiated with 2.160 keV X rays which can ionize the K shell of phosphorus, G values of Adenine, 5'AMP and 5'ADP were estimated to be 1.4, 0.40 and 0.46, respectively. These values were respectively 1.3, 2.9 and 3.8 times higher than those obtained upon irradiation with 2.146 keV X rays which cannot ionize the K shell of phosphorus. These energy dependent enhancements may reflect the difference in energy absorption processes, especially the Auger cascade in phosphorus may be suspected to play an important role in these enhancements

  13. The effects of low-level ionizing radiation and copper exposure on the incidence of antibiotic resistance in lentic biofilm bacteria.

    Science.gov (United States)

    McArthur, J Vaun; Dicks, Christian A; Bryan, A Lawrence; Tuckfield, R Cary

    2017-09-01

    Environmental reservoirs of antibiotic resistant bacteria are poorly understood. Understanding how the environment selects for resistance traits in the absence of antibiotics is critical in developing strategies to mitigate this growing menace. Indirect or co-selection of resistance by environmental pollution has been shown to increase antibiotic resistance. However no attention has been given to the effects of low-level ionizing radiation or the interactions between radiation and heavy metals on the maintenance or selection for antibiotic resistance (AR) traits. Here we explore the effect of radiation and copper on antibiotic resistance. Bacteria were collected from biofilms in two ponds - one impacted by low-level radiocesium and the other an abandoned farm pond. Through laboratory controlled experiments we examined the effects of increasing concentrations of copper on the incidence of antibiotic resistance. Differences were detected in the resistance profiles of the controls from each pond. Low levels (0.01 mM) of copper sulfate increased resistance but 0.5 mM concentrations of copper sulfate depressed the AR response in both ponds. A similar pattern was observed for levels of multiple antibiotic resistance per isolate. The first principal component response of isolate exposure to multiple antibiotics showed significant differences among the six isolate treatment combinations. These differences were clearly visualized through a discriminant function analysis, which showed distinct antibiotic resistance response patterns based on the six treatment groups. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Incidence of thyroid cancer in women in relation to previous exposure to radiation therapy and history of thyroid disease

    International Nuclear Information System (INIS)

    McTiernan, A.M.; Weiss, N.S.; Daling, J.R.

    1984-01-01

    Female residents of 13 counties of Western Washington, in whom papillary, follicular, or mixed papillary-follicular thyroid carcinomas had been diagnosed between 1974 and 1979 were interviewed regarding their medical and reproductive histories and past exposure to radiation treatments. For comparison, a random sample of women from the same population was interviewed. Women who had received radiation treatments to the head or neck prior to 5 years before interview were 16.5 times (95% confidence interval . 8.1-33.5) more likely than unexposed women to develop cancer. The relative risk (RR) was highest for papillary cancer (19.4) but also was elevated substantially for follicular and mixed papillary-follicular tumors. Women first irradiated at age 19 years or younger had a much higher RR than did women irradiated at age 20 or older. Regardless of prior radiation exposure, women who ever had had a goiter were at increased risk of developing thyroid cancer. Women who had ever developed a goiter had 17 times the risk of developing follicular cancer and almost 7 times the risk of developing papillary cancer as compared with women who never had had a goiter. Risk of thyroid cancer was elevated even among women who had had a history of goiter many years prior to diagnosis. A history of thyroid nodules was also a risk factor for papillary and mixed thyroid cancer. Neither a history of hypothyroidism nor hyperthyroidism was found to increase the risk of thyroid cancer

  15. Elevated UV-B radiation incident on Quercus robur leaf canopies enhances decomposition of resulting leaf litter in soil

    International Nuclear Information System (INIS)

    Newsham, K.K.; Greenslade, P.D.; Kennedy, V.H.; McLeod, A.R.

    1999-01-01

    We examined whether the exposure of Quercus robur L. to elevated UV-B radiation (280–315 nm) during growth would influence leaf decomposition rate through effects on litter quality. Saplings were exposed for eight months at an outdoor facility in the UK to a 30% elevation above the ambient level of erythemally weighted UV-B radiation under UV-B treatment arrays of fluorescent lamps filtered with cellulose diacetate, which transmitted both UV-B and UV-A (315–400 nm) radiation. Saplings were exposed to elevated UV-A alone under control arrays of lamps filtered with polyester and to ambient radiation under unenergised arrays of lamps. Abscised leaves from saplings were enclosed in 1 mm2 mesh nylon bags, placed in a Quercus–Fraxinus woodland and were sampled at 0.11, 0.53, 1.10 and 1.33 years for dry weight loss, chemical composition and saprotrophic fungal colonization. At abscission, litters from UV-A control arrays had ≈ 7.5% higher lignin/nitrogen ratios than those from UV-B treatment and ambient arrays (P < 0.06). Dry weight loss of leaves treated with elevated UV-B radiation during growth was 2.5% and 5% greater than that of leaves from UV-A control arrays at 0.53 and 1.33 years, respectively. Litter samples from UV-B treatment arrays lost more nitrogen and phosphorus than samples from ambient arrays and more carbon than samples from UV-A control arrays. The annual fractional weight loss of litter from UV-B treatment arrays was 8% and 6% greater than that of litter from UV-A control and ambient arrays, respectively. Regression analyses indicated that the increased decomposition rate of UV-B treated litters was associated with enhanced colonization of leaves by basidiomycete fungi, the most active members of the soil fungal community, and that the frequency of these fungi was negatively associated with the initial lignin/nitrogen ratio of leaves. (author)

  16. Evaluation of moving-coil loudspeaker and passive radiator parameters using normal-incidence sound transmission measurements: theoretical developments.

    Science.gov (United States)

    Leishman, Timothy W; Anderson, Brian E

    2013-07-01

    The parameters of moving-coil loudspeaker drivers are typically determined using direct electrical excitation and measurement. However, as electro-mechano-acoustical devices, their parameters should also follow from suitable mechanical or acoustical evaluations. This paper presents the theory of an acoustical method of excitation and measurement using normal-incidence sound transmission through a baffled driver as a plane-wave tube partition. Analogous circuits enable key parameters to be extracted from measurement results in terms of open and closed-circuit driver conditions. Associated tools are presented that facilitate adjacent field decompositions and derivations of sound transmission coefficients (in terms of driver parameters) directly from the circuits. The paper also clarifies the impact of nonanechoic receiving tube terminations and the specific benefits of downstream field decompositions.

  17. WE-G-BRA-03: Developing a Culture of Patient Safety Utilizing the National Radiation Oncology Incident Learning System (ROILS)

    Energy Technology Data Exchange (ETDEWEB)

    Hasson, B; Workie, D; Geraghty, C [Anne Arundel Medical Center, Annapolis, MD (United States)

    2015-06-15

    Purpose: To transition from an in-house incident reporting system to a ROILS standards system with the intent to develop a safety focused culture in the Department and enroll in ROILS. Methods: Since the AAPM Safety Summit (2010) several safety and reporting systems have been implemented within the Department. Specific checklists and SBAR reporting systems were introduced. However, the active learning component was lost due to reporting being viewed with distrust and possible retribution.To Facilitate introducing ROILS each leader in the Department received a copy of the ROILS participation guide. Four specific tasks were assigned to each leader: develop a reporting tree, begin the ROILS based system, facilitate adopting ROILS Terminology, and educate the staff on expectations of safety culture. Next, the ROILS questions were broken down into area specific questions (10–15) per departmental area. Excel spreadsheets were developed for each area and setup for error reporting entries. The Role of the Process Improvement Committee (PI) has been modified to review and make recommendations based on the ROILS entries. Results: The ROILS based Reporting has been in place for 4 months. To date 64 reports have been entered. Since the adoption of ROILS the reporting of incidents has increased from 2/month to 18/month on average. Three reports had a dosimetric effect on the patient (<5%) dose variance. The large majority of entries have been Characterized as Processes not followed or not sure how to Characterize, and Human Behavior. Conclusion: The majority of errors are typo’s that create confusion. The introduction of the ROILS standards has provided a platform for making changes to policies that increase patient safety. The goal is to develop a culture that sees reporting at a national level as a safe and effective way to improve our safety, and to dynamically learn from other institutions reporting.

  18. WE-G-BRA-03: Developing a Culture of Patient Safety Utilizing the National Radiation Oncology Incident Learning System (ROILS)

    International Nuclear Information System (INIS)

    Hasson, B; Workie, D; Geraghty, C

    2015-01-01

    Purpose: To transition from an in-house incident reporting system to a ROILS standards system with the intent to develop a safety focused culture in the Department and enroll in ROILS. Methods: Since the AAPM Safety Summit (2010) several safety and reporting systems have been implemented within the Department. Specific checklists and SBAR reporting systems were introduced. However, the active learning component was lost due to reporting being viewed with distrust and possible retribution.To Facilitate introducing ROILS each leader in the Department received a copy of the ROILS participation guide. Four specific tasks were assigned to each leader: develop a reporting tree, begin the ROILS based system, facilitate adopting ROILS Terminology, and educate the staff on expectations of safety culture. Next, the ROILS questions were broken down into area specific questions (10–15) per departmental area. Excel spreadsheets were developed for each area and setup for error reporting entries. The Role of the Process Improvement Committee (PI) has been modified to review and make recommendations based on the ROILS entries. Results: The ROILS based Reporting has been in place for 4 months. To date 64 reports have been entered. Since the adoption of ROILS the reporting of incidents has increased from 2/month to 18/month on average. Three reports had a dosimetric effect on the patient (<5%) dose variance. The large majority of entries have been Characterized as Processes not followed or not sure how to Characterize, and Human Behavior. Conclusion: The majority of errors are typo’s that create confusion. The introduction of the ROILS standards has provided a platform for making changes to policies that increase patient safety. The goal is to develop a culture that sees reporting at a national level as a safe and effective way to improve our safety, and to dynamically learn from other institutions reporting

  19. Fluorescent X-ray computed tomography using synchrotron radiation for imaging nonradioactive tracer materials

    Energy Technology Data Exchange (ETDEWEB)

    Akiba, Masahiro; Yuasa, Tetsuya; Uchida, Akira; Akatsuka, Takao [Yamagata Univ., Yonezawa (Japan). Electrical and Information of Engineering; Takeda, Tohoru; Hyodo, Kazuyuki; Itai, Yuji

    1997-09-01

    We describe a system of fluorescent X-ray computed tomography using synchrotron radiation (SR-FXCT) to image nonradioactive contrast materials. The system operates on the basis of computed tomography (CT) scanned by the pencil beam. In the previous experiment, we have imaged an acrylic cylindrical phantom with cross-shaped channel, filled with a diluted iodine-based tracer material of 200 {mu}g/ml. This research is aimed to improve image quality, to select the optimum energy of the incident X-ray, to confirm quantitative evaluation of the image, and to demonstrate FXCT image for living body. First, we simulated output energy profile by the Monte Carlo simulation and confirmed to predetermine the incident X-ray energy at 37 keV, in order to separate the fluorescent photons from background scattering components. Next, the imaging experiment was performed by using conventional CT algorithm under the optimum parameter at the Tristan Accumulation Ring, KEK, Japan. An acrylic phantom containing five paraxial channels of 5 and 4 mm in diameter, could be imaged; where each channel was respectively filled with diluted iodine-based contrast materials of 50, 100, 200 and 500 {mu}g/ml. From the reconstructed image, we confirmed quantitativity in the FXCT image. Finally, a rat`s brain was imaged in vitro by FXCT and monochromatic transmission CT. The comparison between these results showed that the iodine-rich region in the FXCT image corresponded with that in the monochromatic transmission CT image. (author)

  20. New sub-Doppler absorption resonances in a thin gas cell produced by means of a running monochromatic wave

    International Nuclear Information System (INIS)

    Tajalli, H; Ahmadi, S; Izmailov, A Ch

    2002-01-01

    A theoretical investigation is carried out through the interaction of the plane running monochromatic light wave, having an arbitrary intensity, with atoms (molecules) of a rarefied gas in the plane cell (at the normal incidence of the wave). Cases of closed and open resonance transitions from the non-degenerate ground (or metastable) quantum level are considered. Possible sub-Doppler resonances are analysed in the wave absorption, caused by the transient establishment of the optical coherence on the transition, Rabi oscillations between its levels, and optical pumping during the free flights of particles between the walls of the cell. Results of the previous works on given problems are generalized, which were obtained at definite restrictions on the wave intensity and cell length. Moreover, non-trivial sub-Doppler spectral structures, resulting as a consequence of the dependence of the absorption saturation on the transit relaxation of particles, have been established and investigated. Such structures may consist of a number of peaks and dips caused by Rabi oscillations between the transition levels. The results obtained can be used in sub-Doppler spectroscopy and for the stabilization of laser frequencies in thin gas cells

  1. Progress towards monochromatic imaging of mix at the NIF

    Science.gov (United States)

    Kyrala, G. A.; Murphy, T. J.; Bradley, P. A.; Krashenninnikova, N. S.; Tregillis, I. L.; Obrey, K.; Shah, R. C.; Hakel, P.; Kline, J. L.; Grim, G. P.; Schmitt, M. J.; Kanzleiter, R. J.; Regan, S. P.; Barrios, M. A.

    2013-10-01

    Mix of non-hydrogenic (Z >1) material into the hydrogenic (D and T) ICF capsule fuel degrades implosion performance. The amount of degradation depends on the degree and the spatial distribution of mix. Experiments are underway at NIF to quantify the mix of shell material into fuel using directly driven capsules. CH or CD shells with various dopants, implanted at different depths in the shell are being used to change the amount of dopant mix. Spatially and spectrally resolved emission from the ionized dopants will be used to generate spatially and temporally dependent density and temperature maps of the ionized dopants that are mixed and heated in the core plasma. This information will be used to validate different mix models. This talk will describe the search for the appropriate dopant that gave a radiation spectrum that could be used to record images with the MMI diagnostic. This work is supported by US DOE/NNSA, performed at LANL, operated by LANS LLC under contract DE-AC52-06NA25396.

  2. Monochromatic Measurements of the JPSS-1 VIIRS Polarization Sensitivity

    Science.gov (United States)

    McIntire, Jeff; Moyer, David; Brown, Steven W.; Lykke, Keith R.; Waluschka, Eugene; Oudrari, Hassan; Xiong, Xiaoxiong

    2016-01-01

    Polarization sensitivity is a critical property that must be characterized for spaceborne remote sensing instruments designed to measure reflected solar radiation. Broadband testing of the first Joint Polar-orbiting Satellite System (JPSS-1) Visible Infrared Imaging Radiometer Suite (VIIRS) showed unexpectedly large polarization sensitivities for the bluest bands on VIIRS (centered between 400 and 600 nm). Subsequent ray trace modeling indicated that large diattenuation on the edges of the bandpass for these spectral bands was the driver behind these large sensitivities. Additional testing using the National Institute of Standards and Technologies Traveling Spectral Irradiance and Radiance Responsivity Calibrations Using Uniform Sources was added to the test program to verify and enhance the model. The testing was limited in scope to two spectral bands at two scan angles; nonetheless, this additional testing provided valuable insight into the polarization sensitivity. Analysis has shown that the derived diattenuation agreed with the broadband measurements to within an absolute difference of about0.4 and that the ray trace model reproduced the general features of the measured data. Additionally, by deriving the spectral responsivity, the linear diattenuation is shown to be explicitly dependent on the changes in bandwidth with polarization state.

  3. Multiple scattering of polarized light: comparison of Maxwell theory and radiative transfer theory.

    Science.gov (United States)

    Voit, Florian; Hohmann, Ansgar; Schäfer, Jan; Kienle, Alwin

    2012-04-01

    For many research areas in biomedical optics, information about scattering of polarized light in turbid media is of increasing importance. Scattering simulations within this field are mainly performed on the basis of radiative transfer theory. In this study a polarization sensitive Monte Carlo solution of radiative transfer theory is compared to exact Maxwell solutions for all elements of the scattering Müller matrix. Different scatterer volume concentrations are modeled as a multitude of monodisperse nonabsorbing spheres randomly positioned in a cubic simulation volume which is irradiated with monochromatic incident light. For all Müller matrix elements effects due to dependent scattering and multiple scattering are analysed. The results are in overall good agreement between the two methods with deviations related to dependent scattering being prominent for high volume concentrations and high scattering angles.

  4. Selecting optimal monochromatic level with spectral CT imaging for improving imaging quality in hepatic venography

    International Nuclear Information System (INIS)

    Sun Jun; Luo Xianfu; Wang Shou'an; Wang Jun; Sun Jiquan; Wang Zhijun; Wu Jingtao

    2013-01-01

    Objective: To investigate the effect of spectral CT monochromatic images for improving imaging quality in hepatic venography. Methods: Thirty patients underwent spectral CT examination on a GE Discovery CT 750 HD scanner. During portal phase, 1.25 mm slice thickness polychromatic images and optimal monochromatic images were obtained, and volume rendering and maximum intensity projection were created to show the hepatic veins respectively. The overall imaging quality was evaluated on a five-point scale by two radiologists. Inter-observer agreement in subjective image quality grading was assessed by Kappa statistics. Paired-sample t test were used to compare hepatic vein attenuation, hepatic parenchyma attenuation, CT value difference between the hepatic vein and the liver parenchyma, image noise, vein-to-liver contrast-to-noise ratio (CNR), the image quality score of hepatic venography between the two image data sets. Results: The monochromatic images at 50 keV were found to demonstrate the best CNR for hepatic vein.The hepatic vein attenuation [(329 ± 47) HU], hepatic parenchyma attenuation [(178 ± 33) HU], CT value difference between the hepatic vein and the liver parenchyma [(151 ± 33) HU], image noise (17.33 ± 4.18), CNR (9.13 ± 2.65), the image quality score (4.2 ± 0.6) of optimal monochromatic images were significantly higher than those of polychromatic images [(149 ± 18) HU], [(107 ± 14) HU], [(43 ±11) HU], 12.55 ± 3.02, 3.53 ± 1.03, 3.1 ± 0.8 (t values were 24.79, 13.95, 18.85, 9.07, 13.25 and 12.04, respectively, P < 0.01). In the comparison of image quality, Kappa value was 0.81 with optimal monochromatic images and 0.69 with polychromatic images. Conclusion: Monochromatic images of spectral CT could improve CNR for displaying hepatic vein and improve the image quality compared to the conventional polychromatic images. (authors)

  5. Gamma-H2AX biodosimetry for use in large scale radiation incidents: comparison of a rapid ‘96 well lyse/fix’ protocol with a routine method

    Directory of Open Access Journals (Sweden)

    Jayne Moquet

    2014-03-01

    Full Text Available Following a radiation incident, preliminary dose estimates made by γ-H2AX foci analysis can supplement the early triage of casualties based on clinical symptoms. Sample processing time is important when many individuals need to be rapidly assessed. A protocol was therefore developed for high sample throughput that requires less than 0.1 ml blood, thus potentially enabling finger prick sampling. The technique combines red blood cell lysis and leukocyte fixation in one step on a 96 well plate, in contrast to the routine protocol, where lymphocytes in larger blood volumes are typically separated by Ficoll density gradient centrifugation with subsequent washing and fixation steps. The rapid ‘96 well lyse/fix’ method reduced the estimated sample processing time for 96 samples to about 4 h compared to 15 h using the routine protocol. However, scoring 20 cells in 96 samples prepared by the rapid protocol took longer than for the routine method (3.1 versus 1.5 h at zero dose; 7.0 versus 6.1 h for irradiated samples. Similar foci yields were scored for both protocols and consistent dose estimates were obtained for samples exposed to 0, 0.2, 0.6, 1.1, 1.2, 2.1 and 4.3 Gy of 250 kVp X-rays at 0.5 Gy/min and incubated for 2 h. Linear regression coefficients were 0.87 ± 0.06 (R2 = 97.6% and 0.85 ± 0.05 (R2 = 98.3% for estimated versus actual doses for the routine and lyse/fix method, respectively. The lyse/fix protocol can therefore facilitate high throughput processing for γ-H2AX biodosimetry for use in large scale radiation incidents, at the cost of somewhat longer foci scoring times.

  6. Mechanisms of interaction of monochromatic visible light with cells

    Science.gov (United States)

    Karu, Tiina I.

    1996-01-01

    Biological responses of cells to visible and near IR (laser) radiation occur due to physical and/or chemical changes in photoacceptor molecules, components of respiratory chains (cyt a/a3 in mitochondria). As a result of the photoexcitation of electronic states, the following physical and/or chemical changes can occur: alteration of redox properties and acceleration of electron transfer, changes in biochemical activity due to local transient heating of chromophores, one-electron auto-oxidation and O'2- production, and photodynamic action and 1O2 production. Different reaction channels can be activated to achieve the photobiological macroeffect. The primary physical and/or chemical changes induced by light in photoacceptor molecules are followed by a cascade of biochemical reactions in the cell that do not need further light activation and occur in the dark (photosignal transduction and amplification chains). These reactions are connected with changes in cellular homeostasis parameters. The crucial step here is thought to be an alteration of the cellular redox state: a shift towards oxidation is associated with stimulation of cellular vitality, and a shift towards reduction is linked to inhibition. Cells with a lower than normal pH, where the redox state is shifted in the reduced direction, are considered to be more sensitive to the stimulative action of light than those with the respective parameters being optimal or near optimal. This circumstance explains the possible variations in observed magnitudes of low- power laser effects. Light action on the redox state of a cell via the respiratory chain also explains the diversity of low-power laser effects. Besides explaining many controversies in the field of low-power laser effects (i.e., the diversity of effects, the variable magnitude or absence of effects in certain studies), the proposed redox-regulation mechanism may be a fundamental explanation for some clinical effects of irradiation, for example the positive

  7. Population exposure to ultraviolet radiation in Finland 1920-1995: Exposure trends and a time-series analysis of exposure and cutaneous melanoma incidence

    International Nuclear Information System (INIS)

    Kojo, Katja; Jansen, Christer T.; Nybom, Pia; Huurto, Laura; Laihia, Jarmo; Ilus, Taina; Auvinen, Anssi

    2006-01-01

    Ultraviolet radiation (UVR) is the principal cause of cutaneous malignant melanoma (CMM). However, the relation between CMM and UVR exposure is not clear. We present the trends of population exposure to UVR and conduct a time-series analysis of the relation between UVR exposure and incidence of CMM. Data on CMM incidence were obtained from the Finnish Cancer Registry. Clothing coverage of the body was scored from archival photographs and the proportion of uncovered skin was used as a measure of solar exposure. Information on the number of sunny resort holidays, duration of annual holidays, and sunscreen sales were obtained from various sources. Exposed skin area doubled from 1920 to 1985. The average duration of annual holidays increased 30-fold. The number of sunny resort holidays and the sales of sunscreens increased rapidly from 1980. CMM was most strongly associated with solar exposure of 5-19 years earlier. There is a considerable decrease in clothing coverage during the 20th century. UVR exposure preceding CMM occurrence 4 years or less does not appear relevant, whereas the period 5-19 years prior to CMM occurrence might be the most relevant period. However, findings of ecological studies may not be applicable at the individual level

  8. Application Research of Quasi-monochromatic X-ray Machine Replacing 241Am Radioactive Source in Thickness Measurement

    Directory of Open Access Journals (Sweden)

    LIN Hui1;XIAO Xue-fu2;HOU Yue-xin3;ZHAO Jing1;JIAN Li-min1

    2014-02-01

    Full Text Available In the research of BS-03 thickness detector, a self-designed quasi-monochromatic (50-60 keV X-ray machine was studied as a substitution to Am-241 low energy photon source(1.11×109 Bq)The range of output current, the attenuation of X rays through the steel plate, the aluminum plate, and the organic glass plate and stability of quasi-monochromatic X-ray machine was tested. The result showed that quasi-monochromatic X-ray machine could be an applicable replacement of Am-241 radioactive source.

  9. Synthesizing monochromatic 3-D images by multiple-exposure rainbow holography with vertical area-partition approach

    Institute of Scientific and Technical Information of China (English)

    翟宏琛; 王明伟; 刘福民; 母国光

    2002-01-01

    We report for the first time the theoretical analysis and experimental results of a white-light reconstructed monochromatic 3-D image synthesizing tomograms by multiple rainbow holo-graphy with vertical-area partition (VAP) approach. The theoretical and experimental results show that 3-D monochromatic image can be synthesized by recording the master hologram by VAP ap-proach without any distortions either in gray scale or in geometrical position. A 3-D monochromatic image synthesized from a series of medical tomograms is presented in this paper for the first time.

  10. Investigation of absorbed radiation dose in refraction-enhanced breast tomosynthesis by a Laue case analyser

    International Nuclear Information System (INIS)

    Sato, H.; Ando, M.; Shimao, D.

    2011-01-01

    An early diagnosis system for breast cancer using refraction-enhanced breast tomosynthesis is under development. Tomograms of breast specimens based on refraction-contrast were demonstrated using the simplest shift-and-add tomosynthesis algorithm. Raw projection image data of breast specimens for tomosynthesis were acquired for a total of 51 views over an angle of 50 deg., in increments of 1 deg., by rotating the object. The incident X ray was monochromatic synchrotron radiation with 20 keV. The purpose of this study was to estimate the absorbed dose of a new X-ray imaging method. As breast cancer almost always arises in glandular breast tissue, the average absorbed dose in such glandular tissue should be measured to estimate the radiation risk associated with mammography. The absorbed dose of the mammary gland due to monochromatic X rays was calculated by the Monte Carlo method, and the optimal X ray energy range for refraction-enhanced breast tomosynthesis was investigated through actual measurements. Compared with the conventional method, it was found to be below one-sixth per inspection. (authors)

  11. Establishment Of Illumination System For Investigation Of Monochromatic Lights Combination Effects On In Vitro Plant Growth

    International Nuclear Information System (INIS)

    Le Tien Thanh; Le Ngoc Trieu; Nguyen Tuong Mien; Huynh Thi Trung; Phan Quoc Minh

    2014-01-01

    Super blue and red light LEDs and other electric, electronic components are used to design and establish 11 independent illumination systems, each system can arbitrarily control to operate at 55 molarities of illumination which are different from together in monochromatic lights combination and total illumination intensity based on the microcontrollers. Programs for loading to microcontrollers were created to base on theoretical calculation and experimental correction. The illumination cycles can be controlled by setting the timer. These 11 systems and another fluorescent light illumination were used to execute the experiment for investigation the effects of monochromatic lights combination on in vitro shoot proliferation stage in Chrysanthemum and Phalaenopsis orchid. Results from this experiment showed that illumination intensity of 400 lux is suitable for chrysanthemum, 750 lux is suitable for Phalaenopsis orchid and rate of 70% red light-30% blue light are suitable for both kinds of these plants. (author)

  12. Electromagnetically Induced Transparency and Absorption of A Monochromatic Light Controlled by a Radio Frequency Field

    International Nuclear Information System (INIS)

    Cai Xun-Ming

    2015-01-01

    Electromagnetically induced transparency and absorption of a monochromatic light controlled by a radio frequency field in the cold multi-Zeeman-sublevel atoms are theoretically investigated. These Zeeman sublevels are coupled by a radio frequency (RF) field. Both electromagnetically induced transparency and electromagnetically induced absorption can be obtained by tuning the frequency of RF field for both the linear polarization and elliptical polarization monochromatic lights. When the transfer of coherence via spontaneous emission from the excited state to the ground state is considered, electromagnetically induced absorption can be changed into electromagnetically induced transparency with the change of intensity of radio field. The transparency windows controlled by the RF field can have potential applications in the magnetic-field measurement and quantum information processing. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  13. Towards a Monochromatization Scheme for Direct Higgs Production at FCC-ee

    CERN Document Server

    Valdivia Garcia, Marco Alan; Zimmermann, Frank

    2016-01-01

    Direct Higgs production in e+e− collisions at the FCC is of interest if the centre-of-mass energy spread can be reduced by at least an order of magnitude. A monochromatization scheme, to accomplish this, can be realized with horizontal dispersion of opposite sign for the two colliding beams at the interaction point (IP). We recall historical approaches to monochromatization, then derive a set of IP parameters which would provide the required performance in FCC e+e− collisions at 62.5 GeV beam energy, compare these with the baseline optics parameters at neighbouring energies (45.6 and 80 GeV), comment on the effect of beamstrahlung, and indicate the modifications of the FCC-ee final-focus optics needed to obtain the required parameters.

  14. X-ray imaging with monochromatic synchrotron radiation. Fluorescent and phase-contrast method

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-05-01

    To obtain the high sensitive x-ray images of biomedical object, new x-ray imaging techniques using fluorescent x-ray and phase-contrast x-ray are being developed in Japan. Fluorescent x-ray CT can detect very small amounts of specific elements in the order of ppm at one pixel, whereas phase-contrast x-ray imaging with interferometer can detect minute differences of biological object. Here, our recent experimental results are presented. (author)

  15. Feasibility of Strong and Quasi-Monochromatic Gamma-Ray Generation by the Laser Compton Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jiyoung; Rehman, Haseeb ur; Kim, Yonghee [KAIST, Daejeon (Korea, Republic of)

    2015-10-15

    This is because LCS γ-rays are energy-tunable, quasi-monochromatic, and beam-like. The photon intensity of the mono-chromatic LCS gamma-ray should be high or strong for efficient and high transmutation rate. It was recently reported that a so-called energy-recovery linac system is able to produce a very high-intensity LCS photons in the order of approximately 1013 photons/s economically. It however did not evaluate quality of the LCS photon beam although a quasi-monoenergetic LCS beam is of huge importance in the photo-nuclear transmutation reactions. It is upon this observation that this paper was prepared. Specifically, this work attempts to quantify intensity of the quasi-monochromatic LCS beam from the said linac system. In addition, this paper aims to discuss general characteristics of the LCS photon, and possible approaches to increase its intensity. This paper presents essential characteristics of the laser Compton scattering (LCS) in terms of its photon energy, cross-section and photon intensity. By using different combinations of electron energy, laser energy and scattering angle, we can effectively generate high-intensity and highly-chromatic LCS gamma-rays. Our preliminary analyses indicate that, in view of Compton cross-section, higher-energy photon can be better generated by increasing the electron energy rather than increasing the laser energy. However, in order to maximize the intensity of monochromatic beam, the laser energy should be maximized for a targeted LCS photon energy.

  16. Optimal Monochromatic Energy Levels in Spectral CT Pulmonary Angiography for the Evaluation of Pulmonary Embolism

    Science.gov (United States)

    Wu, Huawei; Zhang, Qing; Hua, Jia; Hua, Xiaolan; Xu, Jianrong

    2013-01-01

    Background The aim of this study was to determine the optimal monochromatic spectral CT pulmonary angiography (sCTPA) levels to obtain the highest image quality and diagnostic confidence for pulmonary embolism detection. Methods The Institutional Review Board of the Shanghai Jiao Tong University School of Medicine approved this study, and written informed consent was obtained from all participating patients. Seventy-two patients with pulmonary embolism were scanned with spectral CT mode in the arterial phase. One hundred and one sets of virtual monochromatic spectral (VMS) images were generated ranging from 40 keV to 140 keV. Image noise, clot diameter and clot to artery contrast-to-noise ratio (CNR) from seven sets of VMS images at selected monochromatic levels in sCTPA were measured and compared. Subjective image quality and diagnostic confidence for these images were also assessed and compared. Data were analyzed by paired t test and Wilcoxon rank sum test. Results The lowest noise and the highest image quality score for the VMS images were obtained at 65 keV. The VMS images at 65 keV also had the second highest CNR value behind that of 50 keV VMS images. There was no difference in the mean noise and CNR between the 65 keV and 70 keV VMS images. The apparent clot diameter correlated with the keV levels. Conclusions The optimal energy level for detecting pulmonary embolism using dual-energy spectral CT pulmonary angiography was 65–70 keV. Virtual monochromatic spectral images at approximately 65–70 keV yielded the lowest image noise, high CNR and highest diagnostic confidence for the detection of pulmonary embolism. PMID:23667583

  17. Studying the effect of spectral variations intensity of the incident solar radiation on the Si solar cells performance

    Directory of Open Access Journals (Sweden)

    Ahmed Elsayed Ghitas

    2012-12-01

    Full Text Available Solar spectral variation is important in characterization of photovoltaic devices. We present results of an experimental investigation of the effects of the daily spectral variation on the device performance of multicrystalline silicon photovoltaic module. The investigation concentrate on the analysis of outdoor solar spectral measurements carried out at 1 min intervals on clear sky days. Short circuit current and open circuit voltage have been measured to describe the module electrical performance. We have shown that the shift in the solar spectrum towards infrared has a negative impact on the device performance of the module. The spectral bands in the visible region contribute more to the short circuit current than the bands in the infrared region while the ultraviolet region contributes least. The quantitative effect of the spectral variation on the performance of the photovoltaic module is reflected on their respective device performance parameters. The decrease in the visible and the increase in infrared of the radiation spectra account for the decreased current collection and hence power of the module.

  18. Comparison of the incidence and time patterns of radiation-induced skin cancer in humans and rats

    International Nuclear Information System (INIS)

    Albert, R.E.; Burns, F.J.; Shore, R.

    1978-01-01

    Cancer induction in rat skin and human skin are compared following exposure to X-rays. The human data were obtained by follow-up of 2213 children irradiated between 1940 and 1959 for tinea capitis (ringworm) of the scalp. The scalp was irradiated at one session using five fields of 100 kVp X-rays. The scalp dose ranged from 500-800 rads. The rats were irradiated on their dorsal skin with a 1100-rad dose of 30 kVp X-rays. The tumours were predominantly basal cell carcinomas in both species. The proportion of people with tumours as a function of elapsed time since exposure was consistent with a power function with an exponent of 5.4, and had reached 3% or 0.08 tumours per person in most recent survey (35 years after exposure). Of the 64 tumours observed in human skin, a substantial proportion was on the directly irradiated skin just outside the hair-covered regions of the scalp. So far there are no tumours among the 530 irradiated nonwhites in the study when about eight cases would be expected in a comparable group of irradiated whites. Only four skin tumours have been observed in 1396 control patients. The temporal curve of radiation-induced tumours for human skin could be approximately superimposed on that for rats by contracting the time scale by a factor of 37.1. The temporal response of the two species is approximately proportional to their median life spans. (author)

  19. Medical applications of synchrotron radiation. Ch. 10

    International Nuclear Information System (INIS)

    Giacomini, J.C.; Gordon, H.J.

    1991-01-01

    Synchrotron radiation has a number of properties which make it uniquely suited for medical diagnostic imaging. The radiation is intense and can be readily monochromatized. With these highly intense, mono-chromatized X-ray beams, iodine K-edge di-chromatography can yield images which greatly enhance the visualization of iodine containing structures. As this technology continues to improve, the possibility of performing diagnostic cardiac, neuroradiological, and other vascular examinations with minimally invasive peripheral venous injections of iodinated contrast agent becomes increasingly practical. (author). 10 refs.; 6 figs

  20. Incidence of fruit flies on coffee and citrus and quarantine treatment of citrus fruits by gamma radiation

    International Nuclear Information System (INIS)

    Raga, Adalton

    1996-01-01

    The objective of this study was to evaluate the fruit fly infestation on coffee and citrus, and also to determine gamma radiation doses for immature stages of Ceratitis capitata and Anastrepha fraterculus, in order to satisfy quarantine regulations. Coffee arabica varieties Icatu Vermelho, Catuai Amarelo, Mundo Novo and Sarchimor showed the highest infestation indices (pupa/berry): 0.53; 0,41; 0.33 and 0.36. respectively Icatu Vermelho and Catuai Vermelho showed the highest values of pupa/berry weight (0.49 and 0.39, respectively), and Robusta (Coffea canephora) presented the lowest index (0.01). The following fruit flies were found in coffee berries: C. capitata (76.6%) Anastrepha spp. (7.4%) and Lonchaeidae (17.0%). In area near coffee plantation, fruit fly infestation indices in sweet oranges were of 4.77 larvae/kg and 0.55 larva/fruit. The infestation indices for sweet orange, collected from five regions of the State of Sao Paulo ranged from 0.73 to 7.60 pupa/kg and 0.12 to 1.27 pupa/fruit. The same species of fruit flies were found in oranges. In the case of C. capitata eggs with 24-48 hours old, 20 Gy prevented completely adult emergence (artificial diet and orange). No emergence of adult occurred when C. capitata larvae of third instar were irradiated at 20 Gy in their rearing medium. But at 25 Gy, the number of adults was reduced by 54% and 97% from larval infestation in oranges and grapefruit, respectively. A dose of 30 Gy was required to prevent medfly emergence from third instar larvae in grapefruit. A dose of 15 Gy was required for third instar, to prevent adult emergence of A. fraterculus. No adult emerged from C third instar, to prevent adult emergence of A. fraterculus. No adult emerged from C capitata pre-pupa irradiated at 30 Gy. One medfly adult emerged from pupa (3-4 days after pupating) irradiated at 120 Gy. At the same dose, sixteen A. fraterculus adults emergency from irradiated pupa with 5-6 days old. (author)

  1. Variation in yield ratios of fragment ions and of ion-pairs from CF2Cl2 following monochromatic soft X-ray absorption

    International Nuclear Information System (INIS)

    Suzuki, I.H.; Saito, N.; Bozek, J.D.

    1995-01-01

    Fragment ions produced from CF 2 Cl 2 have been measured from 44 to 1200eV using a time-of-flight mass spectrometer and monochromatized synchrotron radiation. Positively charged ion pairs from this molecule were observed in the inner-shell excitation regions using a Selected photoion-photoion coincidence technique. Obtained yield ratios of fragment ions indicate that the atomic chlorine ion, Cl + , has the greatest intensity at all photon energies above 60eV and exhibits a steep increase at the Cl L 2,3 -edges. Some fragment ions, in particular CF 2 + , have a clear intensity increase at the transitions of inner-shell electrons to unoccupied molecular orbitals. The ion pair F + - Cl + exhibits the highest yield at most photon energies, and some of the branching ratios for ion-pair production changed significantly near the Cl L 2,3 -edges. (author)

  2. Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

    International Nuclear Information System (INIS)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Mueller, P.; Ulm, G.

    2009-01-01

    Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation.

  3. Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

    Science.gov (United States)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Müller, P.; Ulm, G.

    2009-09-01

    Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation.

  4. Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, M. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Krumrey, M. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)], E-mail: Michael.Krumrey@ptb.de; Cibik, L.; Mueller, P.; Ulm, G. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)

    2009-09-11

    Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation.

  5. Circadian rhythms in the incidence of apoptotic cells and number of clonogenic cells in intestinal crypts after radiation using normal and reversed light conditions

    International Nuclear Information System (INIS)

    Ijiri, K.; Potten, C.S.

    1988-01-01

    Variations in the number of radiation-induced morphologically dead or dying cells (apoptotic cells) in the crypts in the small intestine of the mouse have been studied throughout a 24-h period under a normal light regimen. A clear circadian rhythm was displayed in the apoptotic incidence 3 or 6 h after irradiation for each gamma-ray dose studied (range 0.14-9.0 Gy). The most prominent circadian rhythm was obtained after 0.5 Gy. Peak time of day for inducing apoptosis was 06.00-09.00 h, and the trough occurred at 18.00-21.00 h. Some mice were also transferred to a reversed light cycle, and irradiated on different days after transfer. Apoptosis induced by 0.5 Gy or 9.0 Gy, or number of surviving crypts (microcolonies) after 11.0 Gy or 13.0 Gy was examined. The transition point for reversal of circadian rhythm in apoptosis (after 0.5 Gy) occurred 7 days after transfer and the rhythm was reversed by 14 days. The rhythm for crypt survival (i.e. for clonogenic cell radiosensitivity) was disturbed on 1 day and transition point for reversal occurred 3 days after transfer. The rhythm became reversed by 7 days. (author)

  6. In situ electrochemical impedance spectroscopy/synchrotron radiation grazing incidence X-ray diffraction-A powerful new technique for the characterization of electrochemical surfaces and interfaces

    Energy Technology Data Exchange (ETDEWEB)

    De Marco, Roland [Nanochemistry Research Institute, Department of Applied Chemistry, Curtin University of Technology, GPO Box U 1987, Perth, WA 6845 (Australia)]. E-mail: r.demarco@exchange.curtin.edu.au; Jiang, Z.-T. [Nanochemistry Research Institute, Department of Applied Chemistry, Curtin University of Technology, GPO Box U 1987, Perth, WA 6845 (Australia); Martizano, Jay [Nanochemistry Research Institute, Department of Applied Chemistry, Curtin University of Technology, GPO Box U 1987, Perth, WA 6845 (Australia); Lowe, Alex [Nanochemistry Research Institute, Department of Applied Chemistry, Curtin University of Technology, GPO Box U 1987, Perth, WA 6845 (Australia); Pejcic, Bobby [Nanochemistry Research Institute, Department of Applied Chemistry, Curtin University of Technology, GPO Box U 1987, Perth, WA 6845 (Australia); Riessen, Arie van [Materials Research Group, Department of Applied Physics, Curtin University of Technology, GPO Box U 1987, Perth, WA 6845 (Australia)

    2006-08-15

    A marriage of electrochemical impedance spectroscopy (EIS) and in situ synchrotron radiation grazing incidence X-ray diffraction (SR-GIXRD) has provided a powerful new technique for the elucidation of the mechanistic chemistry of electrochemical systems. In this study, EIS/SR-GIXRD has been used to investigate the influence of metal ion buffer calibration ligands, along with natural organic ligands in seawater, on the behaviour of the iron chalcogenide glass ion-selective electrode (ISE). The SR-GIXRD data demonstrated that citrate - a previously reported poor iron calibration ligand for the analysis of seawater - induced an instantaneous and total dissolution of crystalline GeSe and Sb{sub 2}Se{sub 3} in the modified surface layer (MSL) of the ISE, while natural organic ligands in seawater and a mixture of ligands in a mimetic seawater ligand system protected the MSL's crystalline inclusions of GeSe and Sb{sub 2}Se{sub 3} from oxidative attack. Expectedly, the EIS data showed that citrate induced a loss in the medium frequency time constant for the MSL of the ISE, while seawater's natural organic ligands and the mimetic ligand system preserved the medium frequency EIS response characteristics of the ISE's MSL. The new EIS/SR-GIXRD technique has provided insights into the suitability of iron calibration ligands for the analysis of iron in seawater.

  7. Radiological incidents in radiotherapy

    International Nuclear Information System (INIS)

    Hobzova, L.; Novotny, J.

    2008-01-01

    In many countries a reporting system of radiological incidents to national regulatory body exists and providers of radiotherapy treatment are obliged to report all major and/or in some countries all incidents occurring in institution. State Office for Nuclear Safety (SONS) is providing a systematic guidance for radiotherapy departments from 1997 by requiring inclusion of radiation safety problems into Quality assurance manual, which is the basic document for obtaining a license of SONS for handling with sources of ionizing radiation. For that purpose SONS also issued the recommendation 'Introduction of QA system for important sources in radiotherapy-radiological incidents' in which the radiological incidents are defined and the basic guidance for their classification (category A, B, C, D), investigation and reporting are given. At regular periods the SONS in co-operation with radiotherapy centers is making a survey of all radiological incidents occurring in institutions and it is presenting obtained information in synoptic communication (2003 Motolske dny, 2005 Novy Jicin). This presentation is another summary report of radiological incidents that occurred in our radiotherapy institutions during last 3 years. Emphasis is given not only to survey and statistics, but also to analysis of reasons of the radiological incidents and to their detection and prevention. Analyses of incidents in radiotherapy have led to a much broader understanding of incident causation. Information about the error should be shared as early as possible during or after investigation by all radiotherapy centers. Learning from incidents, errors and near misses should be a part of improvement of the QA system in institutions. Generally, it is recommended that all radiotherapy facilities should participate in the reporting, analyzing and learning system to facilitate the dissemination of knowledge throughout the whole country to prevent errors in radiotherapy.(authors)

  8. Comparison of monochromatic aberrations in young adults with different visual acuity and refractive errors.

    Science.gov (United States)

    Yazar, Seyhan; Hewitt, Alex W; Forward, Hannah; McKnight, Charlotte M; Tan, Alex; Mountain, Jenny A; Mackey, David A

    2014-03-01

    To compare the monochromatic aberrations in a large cohort of 20-year-old Australians with differing levels of visual acuity and explore the relationship between these aberrations and refractive error. Lions Eye Institute, Perth, Western Australia, Australia. Cross-sectional analysis of a population-based cohort. Monochromatic aberrations were measured using a Zywave II wavefront aberrometer with natural pupils in a dark room. The logMAR corrected distance visual acuity (CDVA) was measured monocularly under normal illumination. Cycloplegic autorefraction was also performed. The study enrolled 2039 eyes of 1040 participants. Data from 1007 right eyes were analyzed. The median CDVA and spherical equivalent were -0.06 logMAR (interquartile range [IQR], -0.10 to 0.00) and +0.25 diopters (D) (IQR, -0.38 to 0.63), respectively. The median 6.0 mm higher-order aberration (HOA) was 0.58 μm (IQR, 0.44 to 0.79). Coma-like aberrations and 3rd-, 4th-, and 5th-order HOAs were significantly different between subjects with a CDVA of -0.10 logMAR or better and those with a CDVA worse than -0.10 logMAR. Fourth-order aberrations Z(4,-4) (P=.024) and Z(4,-2) (P=.029) and 2nd-order aberration Z(2,0) (Peyes, emmetropic eyes, and hyperopic eyes. Subjects with higher myopia had slightly higher total HOAs. The HOAs in this population were marginally higher than previously reported values. The findings confirm there is a difference in monochromatic aberrations between different vision and refractive groups. Results in this study will benefit decision-making processes in the clinical setting. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Low luminance/eyes closed and monochromatic stimulations reduce variability of flash visual evoked potential latency

    Directory of Open Access Journals (Sweden)

    Senthil Kumar Subramanian

    2013-01-01

    Full Text Available Context: Visual evoked potentials are useful in investigating the physiology and pathophysiology of the human visual system. Flash visual evoked potential (FVEP, though technically easier, has less clinical utility because it shows great variations in both latency and amplitude for normal subjects. Aim: To study the effect of eye closure, low luminance, and monochromatic stimulation on the variability of FVEPs. Subjects and Methods: Subjects in self-reported good health in the age group of 18-30 years were divided into three groups. All participants underwent FVEP recording with eyes open and with white light at 0.6 J luminance (standard technique. Next recording was done in group 1 with closed eyes, group 2 with 1.2 and 20 J luminance, and group 3 with red and blue lights, while keeping all the other parameters constant. Two trials were given for each eye, for each technique. The same procedure was repeated at the same clock time on the following day. Statistical Analysis: Variation in FVEP latencies between the individuals (interindividual variability and the variations within the same individual for four trials (intraindividual variability were assessed using coefficient of variance (COV. The technique with lower COV was considered the better method. Results: Recording done with closed eyes, 0.6 J luminance, and monochromatic light (blue > red showed lower interindividual and intraindividual variability in P2 and N2 as compared to standard techniques. Conclusions: Low luminance flash stimulations and monochromatic light will reduce FVEP latency variability and may be clinically useful modifications of FVEP recording technique.

  10. Optimal Adaptive Statistical Iterative Reconstruction Percentage in Dual-energy Monochromatic CT Portal Venography.

    Science.gov (United States)

    Zhao, Liqin; Winklhofer, Sebastian; Yang, Zhenghan; Wang, Keyang; He, Wen

    2016-03-01

    The aim of this article was to study the influence of different adaptive statistical iterative reconstruction (ASIR) percentages on the image quality of dual-energy computed tomography (DECT) portal venography in portal hypertension patients. DECT scans of 40 patients with cirrhosis (mean age, 56 years) at the portal venous phase were retrospectively analyzed. Monochromatic images at 60 and 70 keV were reconstructed with four ASIR percentages: 0%, 30%, 50%, and 70%. Computed tomography (CT) numbers of the portal veins (PVs), liver parenchyma, and subcutaneous fat tissue in the abdomen were measured. The standard deviation from the region of interest of the liver parenchyma was interpreted as the objective image noise (IN). The contrast-noise ratio (CNR) between PV and liver parenchyma was calculated. The diagnostic acceptability (DA) and sharpness of PV margins were obtained using a 5-point score. The IN, CNR, DA, and sharpness of PV were compared among the eight groups with different keV + ASIR level combinations. The IN, CNR, DA, and sharpness of PV of different keV + ASIR groups were all statistically different (P ASIR and 70 keV + 0% ASIR (filtered back-projection [FBP]) combination, respectively, whereas the largest and smallest objective IN were obtained in the 60 keV + 0% ASIR (FBP) and 70 keV + 70% combination. The highest DA and sharpness values of PV were obtained at 50% ASIR for 60 keV. An optimal ASIR percentage (50%) combined with an appropriate monochromatic energy level (60 keV) provides the highest DA in portal venography imaging, whereas for the higher monochromatic energy (70 keV) images, 30% ASIR provides the highest image quality, with less IN than 60 keV with 50% ASIR. Copyright © 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  11. Response of vegetable organisms to quasi-monochromatic light of different duration, intensity and wavelength

    Energy Technology Data Exchange (ETDEWEB)

    Budagovsky, A V; Solovykh, N V [I.V.Michurin All-Russian Recearch Institute of Fruit Crops Genetics and Breeding (Russian Federation); Budagovskaya, O N [I.V.Michurin All-Russia Research and Development Institute of Gardening, Michurinsk, Tambov region (Russian Federation); Budagovsky, I A [P N Lebedev Physics Institute, Russian Academy of Sciences, Moscow (Russian Federation)

    2015-04-30

    By the example of vegetable organisms differing in structure and functional properties it is shown that their response to the action of quasi-monochromatic light from laser sources does not obey the Bunsen – Roscoe dose law. The dependence of biological effect on the irradiation time has the multimodal (multiextremal) form with alternating maxima and minima of the stimulating effect. Such a property manifests itself in the spectral ranges, corresponding to photoinduced conversion of chromoproteins of photocontrol systems and is probably related to the cyclic variations of metabolic activity in vegetable cells. (biophotonics)

  12. Solar monochromatic images in magneto-sensitive spectral lines and maps of vector magnetic fields

    Science.gov (United States)

    Shihui, Y.; Jiehai, J.; Minhan, J.

    1985-01-01

    A new method which allows by use of the monochromatic images in some magneto-sensitive spectra line to derive both the magnetic field strength as well as the angle between magnetic field lines and line of sight for various places in solar active regions is described. In this way two dimensional maps of vector magnetic fields may be constructed. This method was applied to some observational material and reasonable results were obtained. In addition, a project for constructing the three dimensional maps of vector magnetic fields was worked out.

  13. X-ray topography under conditions of monochromatic spherical wave diffraction

    International Nuclear Information System (INIS)

    Aristov, V.V.; Polovinkina, V.I.; Ibhikawa, Tetsuya; Kiduta, Seishi.

    1981-01-01

    An X-ray topographic scheme was developed in which there is a large distance between the X-ray source and the specimen. A monochromatic X-ray beam with an angular divergence 6 x 10 - 5 rad obtained by double successive diffraction in the (n 1 , +n 2 ) setting was used. This scheme enables diffraction focusing of a weakly absorbed wave field onto the exit surface of the crystal to be performed. Topographs of a wedge-shaped silicon crystal were obtained. Interference effects such as focusing, anomalous and ordinary Pendelloesung effects peculiar to X-ray spherical wave diffraction were observed in the topographs with high resolution. (author)

  14. Ascent of arches of a monochromatic corona during the eclipse on July 31, 1981

    Energy Technology Data Exchange (ETDEWEB)

    Delone, A B; Makarova, E A; Sikora, Yu [Moskovskij Gosudarstvennyj Univ. (USSR). Gosudarstvennyj Astronomicheskij Inst. ' ' GAISh' ' ; Slovenska Akademia Vied, Bratislava [Czechoslovakia

    1984-04-01

    Velocities of some details of monochromatic corona on July 31, 1981, were measured in the sky plane at the west limb. The ascent of arches and plasmoids clots in the condensations with velocities of about 10 km/s were observed in the green line Fe 14lambda5303. In the red line Fe10lambda6374 the velocities of ascent of two arches were about 11-25 km/s. Each of the investigated details is seen only in one emission line and is absent bout 11-25 km/s.

  15. Blue cone monochromatism in a female due to skewed X-inactivation

    DEFF Research Database (Denmark)

    Frederiksen, Anja Lisbeth; Duno, Morten; Welinder, Lotte G

    2012-01-01

    Blue cone monochromatism (BCM) is a rare cone dystrophy with recessive X-linked inheritance and therefore diagnosed in males whereas females are clinically unaffected. We present a female with clinically manifested BCM. The diagnosis was genetically verified with the identification of one single...... red-green OPN1LW/MW hybrid gene harboring a point mutation c.607C>G, p.Cys203Arg that associates with BCM and in addition a completely biased X-inactivation in DNA isolated from full blood and buccal mucosa. The present case illustrates that females may develop symptoms of recessive X-linked eye...

  16. Towards an Optimized Monochromatization for direct Higgs Production in Future Circular e+ e- Colliders

    CERN Document Server

    García, M A Valdivia

    2017-01-01

    Direct s-channel Higgs production in e+e- collisions is of interest if the centre-of-mass energy spread can be reduced to be comparable to the width of the standard model Higgs boson. A monochromatization principle, previously proposed for several earlier lower-energy colliders, could be employed in order to achieve the desired reduction, by introducing a nonzero horizontal dispersion of opposite sign for the two colliding beams at the interaction point. In high-energy high-luminosity circular colliders, beamstrahlung may increase the energy spread and bunch length. The horizontal emittance blow up due to beamstrahlung, a new effect which was not present in past monochromatization proposals, may degrade the performance, especially the luminosity. We study, for the FCC-ee at 62.5~GeV beam energy, how we can optimize the IP optics parameters, along with the number of particles per bunch so as to obtain maximum luminosity at a desired target value of the collision energy spread.

  17. Frequency-locked pulse sequencer for high-frame-rate monochromatic tissue motion imaging.

    Science.gov (United States)

    Azar, Reza Zahiri; Baghani, Ali; Salcudean, Septimiu E; Rohling, Robert

    2011-04-01

    To overcome the inherent low frame rate of conventional ultrasound, we have previously presented a system that can be implemented on conventional ultrasound scanners for high-frame-rate imaging of monochromatic tissue motion. The system employs a sector subdivision technique in the sequencer to increase the acquisition rate. To eliminate the delays introduced during data acquisition, a motion phase correction algorithm has also been introduced to create in-phase displacement images. Previous experimental results from tissue- mimicking phantoms showed that the system can achieve effective frame rates of up to a few kilohertz on conventional ultrasound systems. In this short communication, we present a new pulse sequencing strategy that facilitates high-frame-rate imaging of monochromatic motion such that the acquired echo signals are inherently in-phase. The sequencer uses the knowledge of the excitation frequency to synchronize the acquisition of the entire imaging plane to that of an external exciter. This sequencing approach eliminates any need for synchronization or phase correction and has applications in tissue elastography, which we demonstrate with tissue-mimicking phantoms. © 2011 IEEE

  18. Monochromatic light-emitting diode (LED source in layers hens during the second production cycle

    Directory of Open Access Journals (Sweden)

    Rodrigo Borille

    2015-09-01

    Full Text Available ABSTRACTLight is an important environmental factor for birds, allowing not only their vision, but also influencing their physiological responses, such as behavioral and reproductive activity. The objective of this experiment was to evaluate the impact of different colors of monochromatic light (LED sources in laying hens production during the second laying cycle. The study was conducted in an experimental laying house during 70 days. A total of 300 laying hens Isa Brown® genetic strain, aged 95 weeks, in the second laying cycle were used in the study. The artificial light sources used were blue, yellow, green, red and white. The light regimen was continuous illumination of 17 h per day (12 h natural and 5 h artificial in a daily light regimen of 17L:5D (light: dark. The Latin Square design was adopted with five treatments (five colors divided into five periods, and five boxes, with six replicates of ten birds in each box. The production and egg quality were evaluated. The different colors of light source did not affect production parameters or egg quality (p > 0.05. The monochromatic light source may be considered as an alternative to artificial lighting in laying hens during the second production cycle.

  19. A pulsed neutron monochromatic beam at the ET-RR-1 reactor

    International Nuclear Information System (INIS)

    Adib, M.; Abdel-Kawy, A.; Eid, Y.; Maayouf, R.M.A.

    1985-01-01

    A pulsed neutron monochromatic beam, at the ET-RR-1 reactor, is produced by two 32 cm diameter rotors suspended in magnetic fields, whose centres are 126 cm apart rotating at speeds up to 16,000 rev/min. Each of the rotors has two slots, which are of constant cross-section in area - 7x10mm 2 , and are curved so that they have a maximum transmission for neutrons whose speed is 8.2 times that of the rotor tip. The jitter of the phase between the rotors at different rotation rates is found not to exceed +-1 μs. It has been found that both the observed time distribution and the TOF distribution of the neutrons at different rotation rates are in good agreement with the calculated ones. The observed intensity of the monochromatic neutrons of wavelength 2.74+-0.09 A, obtained by the rotors rotating at a speed of 10,500 rev/min with 864+-1 μs difference in phase between them, is 66.8 n/s. This value is found to be less than the predicted one by a factor of 5.5. (author)

  20. Analysis of the Relation Between Exposure to Ionising Radiation from Computed Tomography Scans in Childhood and Cancer Incidence within the 'Cohorte Enfant Scanner' Study

    International Nuclear Information System (INIS)

    Journy, Neige

    2014-01-01

    Computed tomography (CT) is a powerful imaging technique that provides great benefits for diagnosis and medical management of patients. Nonetheless, the widespread use of this procedure raises many concerns about the potential adverse effects induced by X-rays exposure, both in clinical practice and in terms of public health. First epidemiological studies have suggested an increased risk of cancer associated with CT scan exposures in childhood or adolescence. The interpretation of these results is, however, controversial, and evidence about radiation-induced risks of cancer is still limited at this level of exposure and during childhood. In France, the 'Enfant Scanner' cohort was set up by IRSN to study the incidence of cancer among more than 100,000 children who received CT scans before the age of 10 in 21 university hospitals. This study is part of the European Epi-CT project - coordinated by the International Agency for Research on Cancer - which includes nine national cohorts set up on the basis of a common protocol. The current thesis, based on the French cohort, focuses on characterizing the exposure of children receiving diagnostic CT scans and quantifying the risk of cancer associated with these exposures. Dosimetric assessment was performed from the radiological protocols used in paediatrics between 2000 and 2011 in the participating hospitals. This study presents the evolution of the exposures during the period and the variability of practices in the radiology departments. The results show that there is a leeway for optimizing the procedures and limiting the exposure of patients, especially for scans of the head that account for most of the examinations in paediatrics. A quantitative assessment of cancer risk potentially induced by CT scans in paediatrics was performed - on the basis of estimates of risk in other contexts of ionizing radiation exposure. The results show that each CT scan could be associated with an excess risk of tumours of the

  1. A compact soft x-ray (0.1–1.2 keV) calibration bench for radiometric measurements using an original versatile Rowland circle grazing incidence monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Hubert, S., E-mail: sebastien.hubert@cea.fr

    2017-05-21

    This paper describes an original Rowland circle grazing incidence spectrometer used as a monochromator for a soft x-ray Manson source in order to calibrate both the source and detectors over the 0.1–1.2 keV spectral range. The originality of the instrument lies on a patented vacuum manipulator which allows the simultaneous boarding of two detectors, one (reference) for measuring the monochromatic radiation and the second to be calibrated. In order to achieve this, the vacuum manipulator is able to interchange, in vacuum, one detector with the other in front of the exit slit of the monochromatizing stage. One purpose of this apparatus was to completely eliminate the intrinsic bremsstrahlung emission of the x-ray diode source and isolate each characteristic line for quantitative detector calibrations. Obtained spectral resolution (Δλ/λ<10{sup −2}) and spectral purity (>98%) fully meet this objective. Initially dimensioned to perform calibration of bulky x-ray cameras unfolded on the Laser MégaJoule Facility, other kinds of detector can be obviously calibrated using this instrument. A brief presentation of the first calibration of an x-ray CCD through its quantum efficiency (QE) measurement is included in this paper as example. Comparison with theoretical model for QE and previous measurements at higher energy are finally presented and discussed.

  2. Radiations

    International Nuclear Information System (INIS)

    Pujol Mora, J.

    1999-01-01

    The exposition to ionizing radiations is a constant fact in the life of the human being and its utilization as diagnostic and therapeutic method is generalized. However, it is notorious how as years go on, the fear to the ionizing radiation seems to persist too, and this fact is not limited to the common individual, but to the technical personnel and professional personnel that labors with them same. (S. Grainger) [es

  3. Radiation

    International Nuclear Information System (INIS)

    Davidson, J.H.

    1986-01-01

    The basic facts about radiation are explained, along with some simple and natural ways of combating its ill-effects, based on ancient healing wisdom as well as the latest biochemical and technological research. Details are also given of the diet that saved thousands of lives in Nagasaki after the Atomic bomb attack. Special comment is made on the use of radiation for food processing. (U.K.)

  4. Radiation

    International Nuclear Information System (INIS)

    Winther, J.F.; Ulbak, K.; Dreyer, L.; Pukkala, E.; Oesterlind, A.

    1997-01-01

    Exposure to solar and ionizing radiation increases the risk for cancer in humans. Some 5% of solar radiation is within the ultraviolet spectrum and may cause both malignant melanoma and non-melanocytic skin cancer; the latter is regarded as a benign disease and is accordingly not included in our estimation of avoidable cancers. Under the assumption that the rate of occurrence of malignant melanoma of the buttocks of both men and women and of the scalp of women would apply to all parts of the body in people completely unexposed to solar radiation, it was estimated that approximately 95% of all malignant melanomas arising in the Nordic populations around the year 2000 will be due to exposure to natural ultraviolet radiation, equivalent to an annual number of about 4700 cases, with 2100 in men and 2600 in women, or some 4% of all cancers notified. Exposure to ionizing radiation in the Nordic countries occurs at an average effective dose per capita per year of about 3 mSv (Iceland, 1.1 mSv) from natural sources, and about 1 mSv from man-made sources. While the natural sources are primarily radon in indoor air, natural radionuclides in food, cosmic radiation and gamma radiation from soil and building materials, the man-made sources are dominated by the diagnostic and therapeutic use of ionizing radiation. On the basis of measured levels of radon in Nordic dwellings and associated risk estimates for lung cancer derived from well-conducted epidemiological studies, we estimated that about 180 cases of lung cancer (1% of all lung cancer cases) per year could be avoided in the Nordic countries around the year 2000 if indoor exposure to radon were eliminated, and that an additional 720 cases (6%) could be avoided annually if either radon or tobacco smoking were eliminated. Similarly, it was estimated that the exposure of the Nordic populations to natural sources of ionizing radiation other than radon and to medical sources will each give rise to an annual total of 2120

  5. Single source dual energy CT: What is the optimal monochromatic energy level for the analysis of the lung parenchyma?

    Energy Technology Data Exchange (ETDEWEB)

    Ohana, M., E-mail: mickael.ohana@gmail.com [iCube Laboratory, Université de Strasbourg/CNRS, UMR 7357, 67400 Illkirch (France); Service de Radiologie B, Nouvel Hôpital Civil – Hôpitaux Universitaires de Strasbourg, 1 place de l’hôpital, 67000 Strasbourg (France); Labani, A., E-mail: aissam.labani@chru-strasbourg.fr [Service de Radiologie B, Nouvel Hôpital Civil – Hôpitaux Universitaires de Strasbourg, 1 place de l’hôpital, 67000 Strasbourg (France); Severac, F., E-mail: francois.severac@chru-strasbourg.fr [Département de Biostatistiques et d’Informatique Médicale, Hôpital Civil – Hôpitaux Universitaires de Strasbourg,1 place de l’hôpital, 67000 Strasbourg (France); Jeung, M.Y., E-mail: Mi-Young.Jeung@chru-strasbourg.fr [Service de Radiologie B, Nouvel Hôpital Civil – Hôpitaux Universitaires de Strasbourg, 1 place de l’hôpital, 67000 Strasbourg (France); Gaertner, S., E-mail: Sebastien.Gaertner@chru-strasbourg.fr [Service de Médecine Vasculaire, Nouvel Hôpital Civil – Hôpitaux Universitaires de Strasbourg,1 place de l’hôpital, 67000 Strasbourg (France); and others

    2017-03-15

    Highlights: • Lung parenchyma aspect varies with the monochromatic energy level in spectral CT. • Optimal diagnostic and image quality is obtained at 50–55 keV. • Mediastinum and parenchyma could be read on the same monochromatic energy level. - Abstract: Objective: To determine the optimal monochromatic energy level for lung parenchyma analysis in spectral CT. Methods: All 50 examinations (58% men, 64.8 ± 16yo) from an IRB-approved prospective study on single-source dual energy chest CT were retrospectively included and analyzed. Monochromatic images in lung window reconstructed every 5 keV from 40 to 140 keV were independently assessed by two chest radiologists. Based on the overall image quality and the depiction/conspicuity of parenchymal lesions, each reader had to designate for every patient the keV level providing the best diagnostic and image quality. Results: 72% of the examinations exhibited parenchymal lesions. Reader 1 picked the 55 keV monochromatic reconstruction in 52% of cases, 50 in 30% and 60 in 18%. Reader 2 chose 50 keV in 52% cases, 55 in 40%, 60 in 6% and 40 in 2%. The 50 and 55 keV levels were chosen by at least one reader in 64% and 76% of all patients, respectively. Merging 50 and 55 keV into one category results in an optimal setting selected by reader 1 in 82% of patients and by reader 2 in 92%, with a 74% concomitant agreement. Conclusion: The best image quality for lung parenchyma in spectral CT is obtained with the 50–55 keV monochromatic reconstructions.

  6. Brain tumors and synchrotron radiation: new methods for mini-beams radiation therapy and treatment follow-up by functional imaging

    International Nuclear Information System (INIS)

    Deman, P.

    2012-01-01

    An innovative method of synchrotron radiation therapy, called mini-beams, was proposed by A. Dilmanian et al. in 2006. Mini-beams consists in tumor irradiation with monochromatic sub-millimetric x-ray beams spatially fractionated produced by a synchrotron source. To obtain a homogeneous dose in the target volume, an interleaving is realized using two orthogonal incidences. Adjacent healthy tissue is only partially irradiated by mini-beams, the areas between the beams only receive scattered radiation and therefore the energy deposited is 10 to 15 times lower than on one mini-beam axis, leading to a sparing effect of healthy tissue even when a high dose is deposited in the target volume. The thesis project is the development of this experimental method of monochromatic mini-beams, which involves the control of the irradiation geometry, the control of dosimetry and its modeling by Monte Carlo simulations. To evaluate the method, preclinical experiments on models of brain tumors implanted in rats (F98) are performed. Follow-up by anatomical and functional imaging is carried out to evaluate the effectiveness of the treatment. Functional imaging of cerebral perfusion (volume and cerebral blood flow, mean transit time of heavy elements) appears to be associated in the literature as a relevant method for monitoring prognostic. The key parameters of the cerebral vasculature are mainly studied in magnetic resonance imaging (MRI), because of the harmlessness of this imaging modality. The relation between MRI signal and contrast agent concentration is very complex and no quantitative relationship is well known. Synchrotron Radiation Computed Tomography (SRCT) is an imaging modality with performances to measure absolute contrast agent concentration very close to the theoretical limits and can be used as gold-standard. The used pharmacokinetic models need as input parameters a contrast agent concentration versus time. A comparison of perfusion measurements between MRI and SRCT

  7. Wheelchair incidents

    NARCIS (Netherlands)

    Drongelen AW van; Roszek B; Hilbers-Modderman ESM; Kallewaard M; Wassenaar C; LGM

    2002-01-01

    This RIVM study was performed to gain insight into wheelchair-related incidents with powered and manual wheelchairs reported to the USA FDA, the British MDA and the Dutch Center for Quality and Usability Research of Technical Aids (KBOH). The data in the databases do not indicate that incidents with

  8. The optimal monochromatic spectral computed tomographic imaging plus adaptive statistical iterative reconstruction algorithm can improve the superior mesenteric vessel image quality

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Xiao-Ping; Zuo, Zi-Wei; Xu, Ying-Jin; Wang, Jia-Ning [CT/MRI room, Affiliated Hospital of Hebei University, Baoding, Hebei, 071000 (China); Liu, Huai-Jun, E-mail: hebeiliu@outlook.com [Department of Medical Imaging, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050000 (China); Liang, Guang-Lu [CT/MRI room, Affiliated Hospital of Hebei University, Baoding, Hebei, 071000 (China); Gao, Bu-Lang, E-mail: browngao@163.com [Department of Medical Research, Shijiazhuang First Hospital, Shijiazhuang, Hebei, 050011 (China)

    2017-04-15

    Objective: To investigate the effect of the optimal monochromatic spectral computed tomography (CT) plus adaptive statistical iterative reconstruction on the improvement of the image quality of the superior mesenteric artery and vein. Materials and methods: The gemstone spectral CT angiographic data of 25 patients were reconstructed in the following three groups: 70 KeV, the optimal monochromatic imaging, and the optimal monochromatic plus 40%iterative reconstruction mode. The CT value, image noises (IN), background CT value and noises, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and image scores of the vessels and surrounding tissues were analyzed. Results: In the 70 KeV, the optimal monochromatic and the optimal monochromatic images plus 40% iterative reconstruction group, the mean scores of image quality were 3.86, 4.24 and 4.25 for the superior mesenteric artery and 3.46, 3.78 and 3.81 for the superior mesenteric vein, respectively. The image quality scores for the optimal monochromatic and the optimal monochromatic plus 40% iterative reconstruction groups were significantly greater than for the 70 KeV group (P < 0.05). The vascular CT value, image noise, background noise, CNR and SNR were significantly (P < 0.001) greater in the optimal monochromatic and the optimal monochromatic images plus 40% iterative reconstruction group than in the 70 KeV group. The optimal monochromatic plus 40% iterative reconstruction group had significantly (P < 0.05) lower image and background noise but higher CNR and SNR than the other two groups. Conclusion: The optimal monochromatic imaging combined with 40% iterative reconstruction using low-contrast agent dosage and low injection rate can significantly improve the image quality of the superior mesenteric artery and vein.

  9. Poster - 27: Incident Learning Practices in Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Angers, Crystal; Medlam, Gaylene; Liszewski, Brian; Simniceanu, Carina [The Ottawa Hospital Cancer Centre, Mississauga Halton/Central West Regional Cancer Center, Odette Cancer Centre, Cancer Care Ontario (Canada)

    2016-08-15

    Purpose: The Radiation Incident and Safety Committee (RISC), established and supported by Cancer Care Ontario (CCO), is responsible for advising the Provincial Head of the Radiation Treatment program on matters relating to provincial reporting of radiation incidents with the goal of improved risk mitigation. Methods: The committee is made up of Radiation Incident Leads (RILs) with representation from each of the 14 radiation medicine programs in the province. RISC routinely meets to review recent critical incidents and to discuss provincial reporting processes and future directions of the committee. Regular face to face meetings have provided an excellent venue for sharing incident learning practices. A summary of the incident learning practices across Ontario has been compiled. Results: Almost all programs in Ontario employ an incident learning committee to review incidents and identify corrective actions or process improvements. Tools used for incident reporting include: paper based reporting, a number of different commercial products and software solutions developed in-house. A wide range of classification schema (data taxonomies) are employed, although most have been influenced by national guidance documents. The majority of clinics perform root cause analyses but utilized methodologies vary significantly. Conclusions: Most programs in Ontario employ a committee approach to incident learning. However, the reporting tools and taxonomies in use vary greatly which represents a significant challenge to provincial reporting. RISC is preparing to adopt the National System for Incident Reporting – Radiation Therapy (NSIR-RT) which will standardize incident reporting and facilitate data analyses aimed at identifying targeted improvement initiatives.

  10. Poster - 27: Incident Learning Practices in Ontario

    International Nuclear Information System (INIS)

    Angers, Crystal; Medlam, Gaylene; Liszewski, Brian; Simniceanu, Carina

    2016-01-01

    Purpose: The Radiation Incident and Safety Committee (RISC), established and supported by Cancer Care Ontario (CCO), is responsible for advising the Provincial Head of the Radiation Treatment program on matters relating to provincial reporting of radiation incidents with the goal of improved risk mitigation. Methods: The committee is made up of Radiation Incident Leads (RILs) with representation from each of the 14 radiation medicine programs in the province. RISC routinely meets to review recent critical incidents and to discuss provincial reporting processes and future directions of the committee. Regular face to face meetings have provided an excellent venue for sharing incident learning practices. A summary of the incident learning practices across Ontario has been compiled. Results: Almost all programs in Ontario employ an incident learning committee to review incidents and identify corrective actions or process improvements. Tools used for incident reporting include: paper based reporting, a number of different commercial products and software solutions developed in-house. A wide range of classification schema (data taxonomies) are employed, although most have been influenced by national guidance documents. The majority of clinics perform root cause analyses but utilized methodologies vary significantly. Conclusions: Most programs in Ontario employ a committee approach to incident learning. However, the reporting tools and taxonomies in use vary greatly which represents a significant challenge to provincial reporting. RISC is preparing to adopt the National System for Incident Reporting – Radiation Therapy (NSIR-RT) which will standardize incident reporting and facilitate data analyses aimed at identifying targeted improvement initiatives.

  11. Contaminated Mexican steel incident

    International Nuclear Information System (INIS)

    1985-01-01

    This report documents the circumstances contributing to the inadvertent melting of cobalt 60 (Co-60) contaminated scrap metal in two Mexican steel foundries and the subsequent distribution of contaminated steel products into the United States. The report addresses mainly those actions taken by US Federal and state agencies to protect the US population from radiation risks associated with the incident. Mexico had much more serious radiation exposure and contamination problems to manage. The United States Government maintained a standing offer to provide technical and medical assistance to the Mexican Government. The report covers the tracing of the source to its origin, response actions to recover radioactive steel in the United States, and return of the contaminated materials to Mexico. The incident resulted in significant radiation exposures within Mexico, but no known significant exposure within the United States. Response to the incident required the combined efforts of the Nuclear Regulatory Commission (NRC), Department of Energy, Department of Transportation, Department of State, and US Customs Service (Department of Treasury) personnel at the Federal level and representatives of all 50 State Radiation Control Programs and, in some instances, local and county government personnel. The response also required a diplomatic interface with the Mexican Government and cooperation of numerous commercial establishments and members of the general public. The report describes the factual information associated with the event and may serve as information for subsequent recommendations and actions by the NRC. 8 figures

  12. Composites with carbon nanotube for radiation shielding application

    International Nuclear Information System (INIS)

    Fontainha, Críssia C.P.; Nunes, Modesto; Rosas, Víctor A.

    2017-01-01

    Polymeric composites filled with attenuating metals and functionalized with carbon nanotubes (NTC) are being largely developed. New attenuators materials have been widely investigated for radiation shielding to apply in procedures as interventional radiology, Computed Tomography (CT) and nuclear medicine. In this work composites for radiation attenuation in radiodiagnostic imaging procedures made of inorganic material as filler, by a sol-gel method, in poly(vinylidene fluoride-tryfluorethylene) [P(VDF-TrFE] copolymers that are used as the polymeric matrix. Two different metal attenuators were used as fillers: zirconia stabilized by yttria (8% wt.) and bismuth oxide. Carbon nanotubes were added with different concentrations at the solution of attenuator metal under controlled magnetic stirring. Characterization of composites by FTIR, UV-Vis, DSC and SEM-EDS were carried out. In a previous analysis of radiation attenuation, was used an incident monochromatic X-ray beam from the RIGAKU diffractometer. In this setup, one reference measure is directly exposed to the x-rays being diffracted by single crystal of Si (111). Another measure the attenuated beam is performed with the composite sample under detector. The functionalization of the carbon nanotube of multiple walls (MWNCT) in the in the P(VDF-TrFE) was evaluated. The samples present a good dispersion of the attenuator metal into presence at methacrylic acid. The cheap tube presented better dispersion in the polymer matrix than the 3100 nanotubes. Bismuth oxidation composites showed a better attenuation factor compared to Zirconia stabilized by yttria composites. (author)

  13. Composites with carbon nanotube for radiation shielding application

    Energy Technology Data Exchange (ETDEWEB)

    Fontainha, Críssia C.P.; Nunes, Modesto; Rosas, Víctor A., E-mail: crissia@gmail.com [Universidade Federal de Minas Gerais (IMA/UFMG), Belo Horizonte, MG (Brazil). Dept. de Anatomia e Imagem; Santos, Adelina P.; Furtado, Clascídia A.; Faria, Luiz O., E-mail: farialo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Polymeric composites filled with attenuating metals and functionalized with carbon nanotubes (NTC) are being largely developed. New attenuators materials have been widely investigated for radiation shielding to apply in procedures as interventional radiology, Computed Tomography (CT) and nuclear medicine. In this work composites for radiation attenuation in radiodiagnostic imaging procedures made of inorganic material as filler, by a sol-gel method, in poly(vinylidene fluoride-tryfluorethylene) [P(VDF-TrFE] copolymers that are used as the polymeric matrix. Two different metal attenuators were used as fillers: zirconia stabilized by yttria (8% wt.) and bismuth oxide. Carbon nanotubes were added with different concentrations at the solution of attenuator metal under controlled magnetic stirring. Characterization of composites by FTIR, UV-Vis, DSC and SEM-EDS were carried out. In a previous analysis of radiation attenuation, was used an incident monochromatic X-ray beam from the RIGAKU diffractometer. In this setup, one reference measure is directly exposed to the x-rays being diffracted by single crystal of Si (111). Another measure the attenuated beam is performed with the composite sample under detector. The functionalization of the carbon nanotube of multiple walls (MWNCT) in the in the P(VDF-TrFE) was evaluated. The samples present a good dispersion of the attenuator metal into presence at methacrylic acid. The cheap tube presented better dispersion in the polymer matrix than the 3100 nanotubes. Bismuth oxidation composites showed a better attenuation factor compared to Zirconia stabilized by yttria composites. (author)

  14. Parametric plasma surface instabilities with s-polarized radiation

    International Nuclear Information System (INIS)

    Rappaport, H.L.

    1994-01-01

    The authors argue that parametric plasma surface mode excitation is a viable broadband instability mechanism in the microwave regime since the wavelength of incident radiation ca be large compared to plasma ion density gradient scale lengths. They restrict their attention to plasmas which are uniform in the planes perpendicular to the density gradients. The boundary is characterized by three parameters: (1) the ion density gradient scale length, (2) the electron Debye length, and (3) the excursion of boundary electrons as they move in response to monochromatic radiation. For s-polarized radiation, equilibrium fluid motion is parallel to the boundary when the ratio of the pump quiver velocity to the speed of light is small. In this case, an abruptly bounded plasma may be modeled with no transition width. If in this case the cold fluid approximation is used as well, the specular and diffuse boundary approximations become the same. A new formation is presented in which pump induced perturbations are expressed as an explicit superposition of linear and non-linear plasma half-space modes. A four-wave interaction is found to produce instability as well as surface wave frequency-shift. This mode is compared against other modes known to exist in this geometry. The theory of surface wave linear mode conversion is reviewed with special attention paid to power flow and energy conservation in this system

  15. An experimental evaluation of monochromatic x-ray beam position monitors at diamond light source

    Energy Technology Data Exchange (ETDEWEB)

    Bloomer, Chris, E-mail: chris.bloomer@diamond.ac.uk; Rehm, Guenther; Dolbnya, Igor P. [Diamond Light Source Ltd, Oxfordshire (United Kingdom)

    2016-07-27

    Maintaining the stability of the X-ray beam relative to the sample point is of paramount importance for beamlines and users wanting to perform cutting-edge experiments. The ability to detect, and subsequently compensate for, variations in X-ray beam position with effective diagnostics has multiple benefits: a reduction in commissioning and start-up time, less ‘down-time’, and an improvement in the quality of acquired data. At Diamond Light Source a methodical evaluation of a selection of monochromatic X-ray Beam Position Monitors (XBPMs), using a range of position detection techniques, and from a range of suppliers, was carried out. The results of these experiments are presented, showing the measured RMS noise on the position measurement of each device for a given flux, energy, beam size, and bandwidth. A discussion of the benefits and drawbacks of each of the various devices and techniques is also included.

  16. An experimental evaluation of monochromatic x-ray beam position monitors at diamond light source

    International Nuclear Information System (INIS)

    Bloomer, Chris; Rehm, Guenther; Dolbnya, Igor P.

    2016-01-01

    Maintaining the stability of the X-ray beam relative to the sample point is of paramount importance for beamlines and users wanting to perform cutting-edge experiments. The ability to detect, and subsequently compensate for, variations in X-ray beam position with effective diagnostics has multiple benefits: a reduction in commissioning and start-up time, less ‘down-time’, and an improvement in the quality of acquired data. At Diamond Light Source a methodical evaluation of a selection of monochromatic X-ray Beam Position Monitors (XBPMs), using a range of position detection techniques, and from a range of suppliers, was carried out. The results of these experiments are presented, showing the measured RMS noise on the position measurement of each device for a given flux, energy, beam size, and bandwidth. A discussion of the benefits and drawbacks of each of the various devices and techniques is also included.

  17. Response of TAPS to monochromatic photons with energies between 45 and 790 MeV

    International Nuclear Information System (INIS)

    Gabler, A.R.; Doering, W.; Fuchs, M.; Krusche, B.; Metag, V.; Novotny, R.; Roebig-Landau, M.; Stroeher, H.; Tries, V.; Molenaar, C.; Loehner, H.; Van Pol, J.H.G.; Raschke, A.; Sumbera, M.; Venema, L.B.; Wilschut, H.W.; Averbeck, R.; Niebur, W.; Schubert, A.; Simon, R.S.; Beck, R.; Peise, J.; Miller, G.J.; Owens, R.O.; Anton, G.

    1994-01-01

    The Two Arm Photon Spectrometer TAPS - comprising 384 plastic-BaF 2 scintillator telescopes - was tested with monochromatic photons in the energy range between 45 and 790 MeV. The energy resolution for a collimated photon beam hitting the central detector module was determined to σ/E=0.59%xE -1/2 γ +1.9% (E γ given in GeV). For the the fast scintillation component alone σ/E=0.79%xE -1/2 γ +1.8% has been measured. The position resolution of the point of impact amounts to Δx=2 cm (FWHM) at the highest energies which corresponds to 30% of the diameter of an individual module. Monte Carlo simulations using the code GEANT3 are in good agreement with the experimental results. ((orig.))

  18. Energy dependence of CP-violation reach for monochromatic neutrino beam

    Science.gov (United States)

    Bernabéu, José; Espinoza, Catalina

    2008-06-01

    The ultimate goal of future neutrino facilities is the determination of CP violation in neutrino oscillations. Besides | U (e 3) | ≠ 0, this will require precision experiments with a very intense neutrino source and energy control. With this objective in mind, the creation of monochromatic neutrino beams from the electron capture decay of boosted ions by the SPS of CERN has been proposed. We discuss the capabilities of such a facility as a function of the energy of the boost and the baseline for the detector. We compare the physics potential for two different configurations: (I) γ = 90 and γ = 195 (maximum achievable at present SPS) to Frejus; (II) γ = 195 and γ = 440 (maximum achievable at upgraded SPS) to Canfranc. We conclude that the SPS upgrade to 1000 GeV is important to reach a better sensitivity to CP violation iff it is accompanied by a longer baseline.

  19. Energy dependence of CP-violation reach for monochromatic neutrino beam

    International Nuclear Information System (INIS)

    Bernabeu, Jose; Espinoza, Catalina

    2008-01-01

    The ultimate goal of future neutrino facilities is the determination of CP violation in neutrino oscillations. Besides |U(e3)|≠0, this will require precision experiments with a very intense neutrino source and energy control. With this objective in mind, the creation of monochromatic neutrino beams from the electron capture decay of boosted ions by the SPS of CERN has been proposed. We discuss the capabilities of such a facility as a function of the energy of the boost and the baseline for the detector. We compare the physics potential for two different configurations: (I) γ=90 and γ=195 (maximum achievable at present SPS) to Frejus; (II) γ=195 and γ=440 (maximum achievable at upgraded SPS) to Canfranc. We conclude that the SPS upgrade to 1000 GeV is important to reach a better sensitivity to CP violation iff it is accompanied by a longer baseline

  20. Monochromatic neutrinos from massive fourth generation neutrino annihilation in the Sun and Earth

    International Nuclear Information System (INIS)

    Belotskij, K.M.; Khlopov, M.Yu.; Shibaev, K.I.

    2001-01-01

    Accumulation inside the Earth and Sun of heavy (with the mass of 50 GeV) primordial neutrinos and antineutrinos of the fourth generation and their successive annihilation is considered. The minimal estimations of annihilational fluxes of monochromatic e, μ, τ neutrinos (neutrinos and antineutrinos) with the energy of 50 GeV are 4.1·10 -6 cm -2 ·s -1 from the Earth core and 1.1·10 -7 cm -2 ·s -1 from the Sun core. That makes the analysis of underground neutrino observatory data the additional source of information on the existence of massive stable 4th generation neutrino. It is shown that due to the kinetic equilibrium between the influx of the neutrinos and their annihilation the existence of new U(1)-gauge interaction of the 4th generation neutrino does not virtually influence the estimations of annihilational e-, μ-, τ-neutrino fluxes

  1. Statistical analysis of monochromatic whistler waves near the Moon detected by Kaguya

    Directory of Open Access Journals (Sweden)

    Y. Tsugawa

    2011-05-01

    Full Text Available Observations are presented of monochromatic whistler waves near the Moon detected by the Lunar Magnetometer (LMAG on board Kaguya. The waves were observed as narrowband magnetic fluctuations with frequencies close to 1 Hz, and were mostly left-hand polarized in the spacecraft frame. We performed a statistical analysis of the waves to identify the distributions of their intensity and occurrence. The results indicate that the waves were generated by the solar wind interaction with lunar crustal magnetic anomalies. The conditions for observation of the waves strongly depend on the solar zenith angle (SZA, and a high occurrence rate is recognized in the region of SZA between 40° to 90° with remarkable north-south and dawn-dusk asymmetries. We suggest that ion beams reflected by the lunar magnetic anomalies are a possible source of the waves.

  2. Computational study of nonlinear plasma waves. I. Simulation model and monochromatic wave propagation

    International Nuclear Information System (INIS)

    Matsuda, Y.; Crawford, F.W.

    1975-01-01

    An economical low-noise plasma simulation model originated by Denavit is applied to a series of problems associated with electrostatic wave propagation in a one-dimensional, collisionless, Maxwellian plasma, in the absence of magnetic field. The model is described and tested, first in the absence of an applied signal, and then with a small amplitude perturbation. These tests serve to establish the low-noise features of the model, and to verify the theoretical linear dispersion relation at wave energy levels as low as 10 -6 of the plasma thermal energy: Better quantitative results are obtained, for comparable computing time, than can be obtained by conventional particle simulation models, or direct solution of the Vlasov equation. The method is then used to study propagation of an essentially monochromatic plane wave. Results on amplitude oscillation and nonlinear frequency shift are compared with available theories

  3. Computational study of nonlinear plasma waves. I. Simulation model and monochromatic wave propagtion

    International Nuclear Information System (INIS)

    Matda, Y.; Crawford, F.W.

    1974-12-01

    An economical low noise plasma simulation model is applied to a series of problems associated with electrostatic wave propagation in a one-dimensional, collisionless, Maxwellian plasma, in the absence of magnetic field. The model is described and tested, first in the absence of an applied signal, and then with a small amplitude perturbation, to establish the low noise features and to verify the theoretical linear dispersion relation at wave energy levels as low as 0.000,001 of the plasma thermal energy. The method is then used to study propagation of an essentially monochromatic plane wave. Results on amplitude oscillation and nonlinear frequency shift are compared with available theories. The additional phenomena of sideband instability and satellite growth, stimulated by large amplitude wave propagation and the resulting particle trapping, are described. (auth)

  4. A compact design for monochromatic OSL measurements in the wavelength range 380-1020 NM

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Poolton, N.R.J.; Willumsen, F.

    1994-01-01

    automated Riso TL/OSL dating apparatus, thus allowing for either routine scanning or more detailed thermo-optical investigations. The high throughput efficiency of the unit means that the existing 75 W tungsten-halogen lamp can be directly used for such measurements on both quartz and feldspar samples......The development and performance of a compact module is described that allows for the monochromatic illumination of samples in the wavelength range 380-1020 nm, enabling the measurement of energy-resolved optically stimulated luminescence. The unit is designed to couple directly to the existing....... The design allows for rapid spectral scanning with a choice of resolution of anywhere between 10 and 80 nm: stray light levels are less than 0.01%. The unit can equally be used for recording wavelength-resolved emission spectra, whether photo-excited or thermally stimulated; the capabilities of the system...

  5. Multiple energy computed tomography with monochromatic x rays from the NSLS

    International Nuclear Information System (INIS)

    Dilmanian, F.A.; Nachaliel, E.; Garrett, R.F.; Thomlinson, W.C.; Chapman, L.D.; Moulin, H.R.; Oversluizen, T.; Rarback, H.M.; Rivers, M.; Spanne, P.; Thompson, A.C.; Zeman, H.D.

    1991-01-01

    We used monochromatic x rays from the X17 superconducting wiggler beamline at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, for dual-energy quantitative computed tomography (CT) of a 27 mm-diameter phantom containing solutions of different KOH concentrations in cylindrical holes of 5-mm diameter. The CT configuration was a fixed horizontal fan-shaped beam of 1.5 mm height and 30 mm width, and a subject rotating around a vertical axis. The transmitted x rays were detected by a linear-array Si(Li) detector with 120 elements of 0.25 mm width each. We used a two-crystal Bragg-Bragg fixed-exit monochromator with Si crystals. Dual photon absorptiometry (DPA) CT data were taken at 20 and 38 keV. The reconstructed phantom images show the potential of the system for quantitative CT

  6. Interstrand DNA crosslinking by 4,5',8-trimethylpsoralen plus monochromatic ultraviolet light

    International Nuclear Information System (INIS)

    Cohen, L.F.; Ewig, R.A.G.; Kohn, K.W.; Glaubiger, D.

    1980-01-01

    DNA crosslinking by 4,5',8-trimethylpsoralen plus monochromatic ultraviolet light of wavelength 365 nm was studied in mouse L1210 leukemia cells. DNA breaks and crosslinking were evaluated by alkaline elution of DNA from poly(vinyl chloride) filters. Trimethylpsoralen plus 365 nm light produced DNA crosslinks but not breaks. The kinetics of crosslinging were linear with respect to concentration and second-order with respect to light exposure time. The latter finding supports the proposed two photon mechanism for the formation of diadducts. In contrast to DNA crosslinking agents such as nitrogen mustard, nitrosoureas and platinums, trimethylpsoralen crosslinks were resistant to proteolytic digestion. Thus, trimethylpsoralen plus 365 nm light produced interstrand crosslinks, as proposed for a bifunctional agent binding to bases on opposite DNA strands. (Auth.)

  7. Inactivation of the lactose permease of Escherichia coli by monochromatic ultraviolet light

    Energy Technology Data Exchange (ETDEWEB)

    Robb, F T; Peak, M J [Rhodes Univ., Grahamstown (South Africa)

    1979-09-01

    The lactose permease of E. coli was inactivated exponetially by seven wavelengths of monochromatic UV light. An action spectrum revealed that the shorter wavelengths (243, 290 and 313 nm) were much more efficient than longer wavelengths. Inactivation at 290 nm was most efficient and was not due to generalized membrane damage. The rate of counterflux of intracellular ..beta..-galactoside in response to externally added ..beta..-galactoside was slowed by 290 nm irradiation, indicating destruction of the facilitated diffusion mechanism. The induction of ..beta..-galactosidase and ..beta..-galactoside permease was co-ordinate both with and without pre-irradiation by 290 nm light. The ..beta.. galactosidase was approximately 26-fold more resistant to 290 nm than the permease. These results are discussed in terms of a greater sensitivity of membrane proteins to 290 nm light, which may be due to the role of aromatic amino acids in conferring stability to the permease in the membrane.

  8. A quasi-monochromatic X-rays source for art painting pigments investigation

    Energy Technology Data Exchange (ETDEWEB)

    Albertin, F.; Franconieri, A.; Gambaccini, M.; Petrucci, F.; Chiozzi, S. [University of Ferrara, Department of Physics and INFN, Ferrara (Italy); Moro, D. [University of Padova, Department of Physics, Padova (Italy); LNL - INFN, Legnaro, Padova (Italy)

    2009-08-15

    Monochromatic X-ray sources can be used for several applications, like in medicine or in studying our cultural heritage. We are investigating imaging systems based on a tuneable energy band X-ray source, to obtain an element mapping of painting layers using the K-edge technique. The narrow energy band beams are obtained with conventional X-ray source via Bragg diffraction on a mosaic crystal; such an analysis has been performed at different diffraction angles, tuning the energy to investigate spectra of interest from the artistic point of view, like zinc and copper. In this paper the characteristics of the system in terms of fluence rate are reported, and first results of this technique on canvas samples and painting are presented. (orig.)

  9. A Photodegradation Study of Three Common Paint and Plaster Biocides under monochromatic UV Light

    DEFF Research Database (Denmark)

    Minelgaite, Greta; Vollertsen, Jes; Nielsen, Asbjørn Haaning

    2014-01-01

    Photodegradation of the three common paint-and-plaster biocides (carbendazim, diuron and terbutryn) was investigated at controlled laboratory conditions. Samples prepared in two types of water (demineralized water and pond water) were subjected to 254 nm monochromatic UV light. Light intensity (W m......-2) in the experimental chamber was measured by a fiber optic spectrometer. The observed decline in biocide concentration was related with the light energy, accumulated during the time of degradation (kJ m-2), and 1st order photodegradation rate constants (m2 kJ-1) were determined. The obtained...... at selected laboratory conditions, as well as emphasize the importance of water type when investigating pollutant’s photo fate, as certain constituents might act as reaction enhancers or inhibitors....

  10. A magnet lattice for a tau-charm factory suitable for both standard scheme and monochromatization scheme

    International Nuclear Information System (INIS)

    Beloshitsky, P.

    1992-06-01

    A versatile magnet lattice for a tau-charm factory is considered in this report. The main feature of this lattice is the possibility to use it for both standard flat beam scheme and beam monochromatization scheme. The detailed description of the lattice is given. The restrictions following the compatibility of both schemes are discussed

  11. Coherence properties of blackbody radiation and application to energy harvesting and imaging with nanoscale rectennas

    Science.gov (United States)

    Lerner, Peter B.; Cutler, Paul H.; Miskovsky, Nicholas M.

    2015-01-01

    Modern technology allows the fabrication of antennas with a characteristic size comparable to the electromagnetic wavelength in the optical region. This has led to the development of new technologies using nanoscale rectifying antennas (rectennas) for solar energy conversion and sensing of terahertz, infrared, and visible radiation. For example, a rectenna array can collect incident radiation from an emitting source and the resulting conversion efficiency and operating characteristics of the device will depend on the spatial and temporal coherence properties of the absorbed radiation. For solar radiation, the intercepted radiation by a micro- or nanoscale array of devices has a relatively narrow spatial and angular distribution. Using the Van Cittert-Zernike theorem, we show that the coherence length (or radius) of solar radiation on an antenna array is, or can be, tens of times larger than the characteristic wavelength of the solar spectrum, i.e., the thermal wavelength, λT=2πℏc/(kBT), which for T=5000 K is about 3 μm. Such an effect is advantageous, making possible the rectification of solar radiation with nanoscale rectenna arrays, whose size is commensurate with the coherence length. Furthermore, we examine the blackbody radiation emitted from an array of antennas at temperature T, which can be quasicoherent and lead to a modified self-image, analogous to the Talbot-Lau self-imaging process but with thermal rather than monochromatic radiation. The self-emitted thermal radiation may be important as a nondestructive means for quality control of the array.

  12. The potential of dual-energy virtual monochromatic imaging in reducing renal cyst pseudoenhancement. A phantom study

    International Nuclear Information System (INIS)

    Yamada, Sachiko; Ueguchi, Takashi; Ukai, Isao; Nagai, Yumiko; Yamakawa, Masanobu; Shimosegawa, Eku; Shimazu, Takeshi; Hatazawa, Jun

    2012-01-01

    Renal cyst pseudoenhancement, an artifactual increase of computed tomography (CT) attenuation for cysts with increased iodine concentrations in the renal parenchyma, complicates the classification of cysts and may thus lead to the mischaracterization of a benign non-enhancing lesion as an enhancing mass. The purpose of this study was to use a phantom model to assess the ability of dual-energy virtual monochromatic imaging to reduce renal pseudoenhancement. A water-filled cylindrical cyst model suspended in varying concentrations of iodine solution, to simulate varying levels of parenchymal enhancement, was scanned with a dual-energy CT scanner using the following three scanning protocols with different combinations of tube voltage: 80 and 140 kV; 80 and 140 kV with tin filter; and 100 and 140 kV with tin filter. Virtual monochromatic images were then synthesized for each dual-energy scan. Single-energy scan with a tube voltage of 120 kV was also performed to obtain polychromatic images as controls. Mean attenuation values (in Hounsfield units) of cyst proxies were measured on both polychromatic and virtual monochromatic images. Pseudoenhancement was considered to be present when the cyst attenuation level increased by more than 10 HU (Hounsfield Unit) as the background iodine concentration increased from 0.0% to 0.4%, 1.5%, or 2.5%. Our results revealed that pseudoenhancement was not observed on any of the monochromatic images, but appeared on polychromatic images at a background iodine concentration of 2.5%. We thus conclude that dual-energy virtual monochromatic images have a potential to reduce renal pseudoenhancement. (author)

  13. Incidents analysis

    International Nuclear Information System (INIS)

    Francois, P.

    1996-01-01

    We undertook a study programme at the end of 1991. To start with, we performed some exploratory studies aimed at learning some preliminary lessons on this type of analysis: Assessment of the interest of probabilistic incident analysis; possibility of using PSA scenarios; skills and resources required. At the same time, EPN created a working group whose assignment was to define a new approach for analysis of incidents on NPPs. This working group gave thought to both aspects of Operating Feedback that EPN wished to improve: Analysis of significant incidents; analysis of potential consequences. We took part in the work of this group, and for the second aspects, we proposed a method based on an adaptation of the event-tree method in order to establish a link between existing PSA models and actual incidents. Since PSA provides an exhaustive database of accident scenarios applicable to the two most common types of units in France, they are obviously of interest for this sort of analysis. With this method we performed some incident analyses, and at the same time explores some methods employed abroad, particularly ASP (Accident Sequence Precursor, a method used by the NRC). Early in 1994 EDF began a systematic analysis programme. The first, transient phase will set up methods and an organizational structure. 7 figs

  14. Incidents analysis

    Energy Technology Data Exchange (ETDEWEB)

    Francois, P

    1997-12-31

    We undertook a study programme at the end of 1991. To start with, we performed some exploratory studies aimed at learning some preliminary lessons on this type of analysis: Assessment of the interest of probabilistic incident analysis; possibility of using PSA scenarios; skills and resources required. At the same time, EPN created a working group whose assignment was to define a new approach for analysis of incidents on NPPs. This working group gave thought to both aspects of Operating Feedback that EPN wished to improve: Analysis of significant incidents; analysis of potential consequences. We took part in the work of this group, and for the second aspects, we proposed a method based on an adaptation of the event-tree method in order to establish a link between existing PSA models and actual incidents. Since PSA provides an exhaustive database of accident scenarios applicable to the two most common types of units in France, they are obviously of interest for this sort of analysis. With this method we performed some incident analyses, and at the same time explores some methods employed abroad, particularly ASP (Accident Sequence Precursor, a method used by the NRC). Early in 1994 EDF began a systematic analysis programme. The first, transient phase will set up methods and an organizational structure. 7 figs.

  15. Predominance of membrane damage in yeast cells in suspension with monochromatic 163-nm vacuum ultraviolet light

    International Nuclear Information System (INIS)

    Ito, T.; Ito, A.

    1980-01-01

    Effects of monochromatic 163-nm ultraviolet light on aqueous suspensions of yeast cells were studied under N 2 and O 2 bubbling conditions. This is a continuation of previous attempts at using a bromine resonance lamp immersed in cell suspension as a means of treating cells with water radicals (163-nm photons decompose water molecules into H atoms and OH' radicals). We found that inactivation occurred only under O 2 bubbling. Genetic changes were induced, but this was attributed to the effects of far-uv components which contaminate the emission. A characteristic feature of the vacuum uv inactivation was a decrease in survival when cells were held in liquid after irradiation. The presence of p-nitrosodimethylaniline (a known OH' scavenger) during irradiation prevented the O 2 -dependent enhancement of inactivation. Cells irradiated under N 2 bubbling showed no such enhancement. Thus, the fast access of oxygen is a necessary condition for fixing initial damage. Initial damage of this type seems to be amplified during subsequent incubation, causing further killing. Cells irradiated under N 2 bubbling were not, however, free of damage, since dye permeability across the cell membrane of irradiated samples increased markedly with both N 2 and O 2 as tested by photodynamic induction of genetic changes using normally unpenetrable dye as a sensitizer. Spectrophotometric evidence for the presence of toluidine blue in the irradiated cells are also presented

  16. Magnetic orientation in birds: non-compass responses under monochromatic light of increased intensity.

    Science.gov (United States)

    Wiltschko, Wolfgang; Munro, Ursula; Ford, Hugh; Wiltschko, Roswitha

    2003-10-22

    Migratory Australian silvereyes (Zosterops lateralis) were tested under monochromatic light at wavelengths of 424 nm blue and 565 nm green. At a low light level of 7 x 10(15) quanta m(-2) s(-1) in the local geomagnetic field, the birds preferred their seasonally appropriate southern migratory direction under both wavelengths. Their reversal of headings when the vertical component of the magnetic field was inverted indicated normal use of the avian inclination compass. A higher light intensity of 43 x 10(15) quanta m(-2) s(-1), however, caused a fundamental change in behaviour: under bright blue, the silvereyes showed an axial tendency along the east-west axis; under bright green, they showed a unimodal preference of a west-northwesterly direction that followed a shift in magnetic north, but was not reversed by inverting the vertical component of the magnetic field. Hence it is not based on the inclination compass. The change in behaviour at higher light intensities suggests a complex interaction between at least two receptors. The polar nature of the response under bright green cannot be explained by the current models of light-dependent magnetoreception and will lead to new considerations on these receptive processes.

  17. The capabilities of monochromatic EC neutrino beams with the SPS upgrade

    International Nuclear Information System (INIS)

    Espinoza, C; Bernabeu, J

    2008-01-01

    The goal for future neutrino facilities is the determination of the U(e3) mixing and CP violation in neutrino oscillations. This will require precision experiments with a very intense neutrino source and energy control. With this objective in mind, the creation of monochromatic neutrino beams from the electron capture decay of boosted ions by the SPS of CERN has been proposed. We discuss the capabilities of such a facility as a function of the energy of the boost and the baseline for the detector. We conclude that the SPS upgrade to 1000 GeV is crucial to reach a better sensitivity to CP violation iff it is accompanied by a longer baseline. We compare the physics potential for two different configurations: I) γ = 90 and γ = 195 (maximum achievable at present SPS) to Frejus; II) γ = 195 and γ = 440 (maximum achievable at upgraded SPS) to Canfranc. The main conclusion is that, whereas the gain in the determination of U(e3) is rather modest, setup II provides much better sensitivity to CP violation

  18. The capabilities of monochromatic EC neutrino beams with the SPS upgrade

    Science.gov (United States)

    Espinoza, C.; Bernabéu, J.

    2008-05-01

    The goal for future neutrino facilities is the determination of the U(e3) mixing and CP violation in neutrino oscillations. This will require precision experiments with a very intense neutrino source and energy control. With this objective in mind, the creation of monochromatic neutrino beams from the electron capture decay of boosted ions by the SPS of CERN has been proposed. We discuss the capabilities of such a facility as a function of the energy of the boost and the baseline for the detector. We conclude that the SPS upgrade to 1000 GeV is crucial to reach a better sensitivity to CP violation iff it is accompanied by a longer baseline. We compare the physics potential for two different configurations: I) γ = 90 and γ = 195 (maximum achievable at present SPS) to Frejus; II) γ = 195 and γ = 440 (maximum achievable at upgraded SPS) to Canfranc. The main conclusion is that, whereas the gain in the determination of U(e3) is rather modest, setup II provides much better sensitivity to CP violation.

  19. Experimental and Numerical Studies on Wave Breaking Characteristics over a Fringing Reef under Monochromatic Wave Conditions

    Directory of Open Access Journals (Sweden)

    Jong-In Lee

    2014-01-01

    Full Text Available Fringing reefs play an important role in protecting the coastal area by inducing wave breaking and wave energy dissipation. However, modeling of wave transformation and energy dissipation on this topography is still difficult due to the unique structure. In the present study, two-dimensional laboratory experiments were conducted to investigate the cross-shore variations of wave transformation, setup, and breaking phenomena over an idealized fringing reef with the 1/40 reef slope and to verify the Boussinesq model under monochromatic wave conditions. One-layer and two-layer model configurations of the Boussinesq model were used to figure out the model capability. Both models predicted well (r2>0.8 the cross-shore variation of the wave heights, crests, troughs, and setups when the nonlinearity is not too high (A0/h0<0.07 in this study. However, as the wave nonlinearity and steepness increase, the one-layer model showed problems in prediction and stability due to the error on the vertical profile of fluid velocity. The results in this study revealed that one-layer model is not suitable in the highly nonlinear wave condition over a fringing reef bathymetry. This data set can contribute to the numerical model verification.

  20. On the stochastic interaction of monochromatic Alfven waves with toroidally trapped particles

    International Nuclear Information System (INIS)

    Krlin, L.; Pavlo, P.; Tluchor, Z.; Gasek, Z.

    1987-07-01

    Monochromatic Alfven wave interaction with toroidaly trapped particles in the intrinsic stochasticity regime is discussed. Both the diffusion in velocities and in the radial position of bananas is studied. Using a suitable Hamiltonian formalism, the effect of wave parallel components E-tilde paral and B-tilde paral is investigated. The stochasticity threshold is estimated for plasma electrons and for thermonuclear alpha-particles (neglecting the effect of B-tilde paral ) by means of direct numerical integration of the corresponding canonical equations. Stochasticity causes transfer between trapped and untrapped regimes and the induced radial diffusion of bananas. The latter effect can considerably exceed neoclassical diffusion. The effect of B-tilde paral was only estimated analytically. It consisted in frequency modulation of the banana periodic motion coupled with a possible Mathieu instability. Nevertheless, for B-tilde paral corresponding to E-tilde paral , the effect seems to be weaker than the effect of E-tilde paral when the thermonuclear regime is considered. (author). 14 figs., 36 refs

  1. Conceptual Design of Dielectric Accelerating Structures for Intense Neutron and Monochromatic X-ray Sources

    Science.gov (United States)

    Blanovsky, Anatoly

    2004-12-01

    Bright compact photon sources, which utilize electron beam interaction with periodic structures, may benefit a broad range of medical, industrial and scientific applications. A class of dielectric-loaded periodic structures for hard and soft X-ray production has been proposed that would provide a high accelerating gradient when excited by an external RF and/or primary electron beam. Target-distributed accelerators (TDA), in which an additional electric field compensates for lost beam energy in internal targets, have been shown to provide the necessary means to drive a high flux subcritical reactor (HFSR) for nuclear waste transmutation. The TDA may also be suitable for positron and nuclear isomer production, X-ray lithography and monochromatic computer tomography. One of the early assumptions of the theory of dielectric wake-field acceleration was that, in electrodynamics, the vector potential was proportional to the scalar potential. The analysis takes into consideration a wide range of TDA design aspects including the wave model of observed phenomena, a layered compound separated by a Van der Waals gap and a compact energy source based on fission electric cells (FEC) with a multistage collector. The FEC is a high-voltage power source that directly converts the kinetic energy of the fission fragments into electrical potential of about 2MV.

  2. SNAPSHOT SPECTRAL AND COLOR IMAGING USING A REGULAR DIGITAL CAMERA WITH A MONOCHROMATIC IMAGE SENSOR

    Directory of Open Access Journals (Sweden)

    J. Hauser

    2017-10-01

    Full Text Available Spectral imaging (SI refers to the acquisition of the three-dimensional (3D spectral cube of spatial and spectral data of a source object at a limited number of wavelengths in a given wavelength range. Snapshot spectral imaging (SSI refers to the instantaneous acquisition (in a single shot of the spectral cube, a process suitable for fast changing objects. Known SSI devices exhibit large total track length (TTL, weight and production costs and relatively low optical throughput. We present a simple SSI camera based on a regular digital camera with (i an added diffusing and dispersing phase-only static optical element at the entrance pupil (diffuser and (ii tailored compressed sensing (CS methods for digital processing of the diffused and dispersed (DD image recorded on the image sensor. The diffuser is designed to mix the spectral cube data spectrally and spatially and thus to enable convergence in its reconstruction by CS-based algorithms. In addition to performing SSI, this SSI camera is capable to perform color imaging using a monochromatic or gray-scale image sensor without color filter arrays.

  3. Micron-CT using quasi-monochromatic x-rays produced in micro-PIXE

    International Nuclear Information System (INIS)

    Ishii, K.

    2009-01-01

    In ion-atom collision, characteristic X-rays are intensively produced and can be considered as a monochromatic X-ray source. We apply this feature to X-ray CT. By using micro-beams, cross sectional images can be provided with a spatial resolution of about 1 μm. On the basis of this idea, we developed a micron-CT consisting of a micro-beam system and an X-ray CCD camera. A tube holding samples was rotated by a stepping motor and the transmission images of the sample were taken with characteristic K-X-rays of Ti (4.558 keV) produced by 3 MeV proton micro-beams. After image reconstruction, images of cross sections of small objects were obtained with a spatial resolution of 3 μm. Using an absorption edge, we can identify an element in a sample. It is expected that our micron-CT can provide cross sectional images of in-vivo cellular samples and can be applied to a wide range of researches in biology and medicine. (author)

  4. A review of monochromatic light devices for the treatment of alopecia areata.

    Science.gov (United States)

    Darwin, Evan; Arora, Harleen; Hirt, Penelope A; Wikramanayake, Tongyu Cao; Jimenez, Joaquin J

    2018-02-01

    There are many laser technologies that are being tested that claim to support hair regrowth for patients with alopecia areata (AA). In this paper, we will determine whether the body of evidence supports the use of devices using monochromatic light sources to treat AA. Articles were gathered from PubMed, Embase, and the Cochrane database using these keywords: lasers, excimer laser, low-level laser therapy (LLLT), low-level light therapy, alopecia, alopecia areata, and hair loss with a category modifier of English. Ten clinical trials and seven case reports/abstracts were assessed. Eight clinical trials and two case reports demonstrated hair regrowth with the 308-nm excimer laser/light in men, women, and children. One case report demonstrated hair regrowth with the ALBA 355® laser. One clinical trial and two case reports demonstrated hair regrowth with LLLT. While two case reports demonstrated hair regrowth with fractional laser therapy, one clinical trial showed no improvement. The 308-nm excimer laser is a safe and effective treatment for men, women, and children with refractory AA of the scalp and beard. Larger, double-blinded clinical trials should be conducted to compare excimer laser therapy to standard treatments. More data is needed to determine the efficacy of LLLT and fractional laser therapy in the treatment of AA.

  5. An ultrabright and monochromatic electron point source made of a LaB6 nanowire

    Science.gov (United States)

    Zhang, Han; Tang, Jie; Yuan, Jinshi; Yamauchi, Yasushi; Suzuki, Taku T.; Shinya, Norio; Nakajima, Kiyomi; Qin, Lu-Chang

    2016-03-01

    Electron sources in the form of one-dimensional nanotubes and nanowires are an essential tool for investigations in a variety of fields, such as X-ray computed tomography, flexible displays, chemical sensors and electron optics applications. However, field emission instability and the need to work under high-vacuum or high-temperature conditions have imposed stringent requirements that are currently limiting the range of application of electron sources. Here we report the fabrication of a LaB6 nanowire with only a few La atoms bonded on the tip that emits collimated electrons from a single point with high monochromaticity. The nanostructured tip has a low work function of 2.07 eV (lower than that of Cs) while remaining chemically inert, two properties usually regarded as mutually exclusive. Installed in a scanning electron microscope (SEM) field emission gun, our tip shows a current density gain that is about 1,000 times greater than that achievable with W(310) tips, and no emission decay for tens of hours of operation. Using this new SEM, we acquired very low-noise, high-resolution images together with rapid chemical compositional mapping using a tip operated at room temperature and at 10-times higher residual gas pressure than that required for W tips.

  6. Instability of surface electron cyclotron TM-modes influenced by non-monochromatic alternating electric field

    International Nuclear Information System (INIS)

    Girka, I. O.; Girka, V. O.; Sydora, R. D.; Thumm, M.

    2016-01-01

    The influence of non-monochromaticity of an external alternating electric field on excitation of TM eigenmodes at harmonics of the electron cyclotron frequency is considered here. These TM-modes propagate along the plasma interface in a metal waveguide. An external static constant magnetic field is oriented perpendicularly to the plasma interface. The problem is solved theoretically using the kinetic Vlasov-Boltzmann equation for description of plasma particles motion and the Maxwell equations for description of the electromagnetic mode fields. The external alternating electric field is supposed to be a superposition of two waves, whose amplitudes are different and their frequencies correlate as 2:1. An infinite set of equations for electric field harmonics of these modes is derived with the aid of nonlinear boundary conditions. This set is solved using the wave packet approach consisting of the main harmonic frequency and two nearest satellite temporal harmonics. Analytical studies of the obtained set of equations allow one to find two different regimes of parametric instability, namely, enhancement and suppression of the instability. Numerical analysis of the instability is carried out for the three first electron cyclotron harmonics.

  7. Study of the initial processes of radiation effects using synchrotron radiation

    International Nuclear Information System (INIS)

    Kobayashi, Katsumi

    1990-01-01

    Necessity for the research of production mechanisms of molecular damages in biological system and usefulness of monochromatic soft X-ray in these studies are described. Synchrotron radiation are introduced as a strong light source with continuous spectrum. Practically, it is the only light source in soft X-ray and vacuum UV region. Development of irradiation apparatus for radiation biology and recent results using various biological systems are reviewed. (author)

  8. Parametric plasma surface instabilities with p-polarized radiation

    International Nuclear Information System (INIS)

    Rappaport, H.L.

    1994-01-01

    The authors argue that parametric plasma surface mode excitation is a viable broadband instability mechanism in the microwave regime since the wavelength of incident radiation can be large compared to plasma ion density gradient scale lengths. The authors restrict their attention to plasmas which are uniform in the planes perpendicular to the density gradients. The boundary region is characterized by three parameters: (1) the ion density gradient length; (2) the electron Debye length; and (3) the excursion of boundary electrons as they move in response to monochromatic p-polarized radiation. A thin vacuum plasma transition layer, in which the ion density gradient scale length is large compared with the Debye length and the electron excursion, is included in the analysis of plasma stability. The recently proposed Lagrangian Frame Two-Plasmon Decay mode (LFTPD) is investigated in the regime in which the instability is not resonantly coupled to surface waves propagating along the boundary region. In this case they have found both spatially dependent growth rate profiles and spatially dependent transit layer magnetic fields due to nonlinear surface currents. LFTPD growth rate profiles are displayed as a function of pump amplitude. The results of a time domain simulation of this mode is also shown

  9. Investigation of the effects of monochromatic lights combination on Phalaenopsis orchid and chrysanthemum in vitro plant growth

    International Nuclear Information System (INIS)

    Le Tien Thanh; Nguyen Tuong Mien; Huynh Thi Trung; Vu Thi Trac; Pham Van Nhi

    2016-01-01

    Eleven independent monochromatic light combination systems were established using super blue and red light LEDs. These are adjustable for mixing ratio of red and blue lights, the intensity and time for illumination. A fluorescent light illumination system was included as control. These were used to implement experiments for investigation effects of monochromatic lights combination in in vitro plantlet fully-forming stage on in vitro plantlet fully-forming and on the development of plant in nursery of chrysanthemum and Phalaenopsis orchid. Results from these experiments showed that illumination with intensity of 750 lx and light mixture of 20% blue-80% red is suitable for Phalaenopsis orchid; illumination with intensity of 1100 lx and light mixture of 90% red light-10% blue light is suitable for chrysanthemum. (author)

  10. Performance of computed tomography for contrast agent concentration measurements with monochromatic x-ray beams: comparison of K-edge versus temporal subtraction

    International Nuclear Information System (INIS)

    Elleaume, H.; Charvet, A.M.; Corde, S.; Esteve, F.; Le Bas, J.F.

    2002-01-01

    We investigated the performance of monochromatic computed tomography for the quantification of contrast agent concentrations. Two subtraction methods (K-edge subtraction and temporal subtraction) were evaluated and compared theoretically and experimentally in terms of detection limit, precision and accuracy. Measurements were performed using synchrotron x-rays with Lucite phantoms (10 cm and 17.5 cm in diameter) containing iodine or gadolinium solutions ranging from 50 μg ml -1 to 5 mg ml -1 . The experiments were carried out using monochromators developed at the European Synchrotron Radiation Facility (ESRF) medical beamline. The phantoms were imaged either above and below the contrast agent K-edge, or before and after the addition of the contrast agent. Both methods gave comparable performance for phantoms less than 10 cm in diameter. For large phantoms, equivalent to a human head, the temporal subtraction is more suitable for detecting elements such as iodine, keeping a reasonable x-ray dose delivered to the phantom. A good agreement was obtained between analytical calculations, simulations and measurements. The beam harmonic content was taken into account in the simulations. It explains the performance degradation with high contrast agent concentrations. The temporal subtraction technique has the advantage of energy tunability and is well suited for imaging elements, such as iodine or gadolinium, in highly absorbing samples. For technical reasons, the K-edge method is preferable when the imaged organ is moving since the two measurements can be performed simultaneously, which is mandatory for obtaining a good subtraction. (author)

  11. Base substitution spectra of nalidixylate resistant mutations induced by monochromatic soft X and 60Co γ-rays in bacillus subtilis spores

    International Nuclear Information System (INIS)

    Takahashi, Nobuhiro; Hieda, Kotaro; Morohoshi, Fumiko; Munakata, Nobuo

    1999-01-01

    Bacillus subtilis spores were exposed to three types of photons, monochromatic soft X-rays with the energy corresponding to the absorption peak of phosphorus K-shell electron (2,153 eV) and with the slightly lower energy (2,147 eV), and 60 Co γ-rays. From the irradiated spores, 233 mutants exhibiting nalidixic acid resistance were isolated, and together with 94 spontaneous mutants, the sequence changes in the 5'-terminal region of the gyrA gene coding for DNA gyrase subunit A were determined. Among eighteen alleles of the gyrA mutations, eight were single-base substitutions, nine were tandem double-base substitutions, and one was a double substitution skipping a middle base pair. About 6% of the radiation-induced mutations were tandem double-base substitutions, whereas none was observed among the spontaneous ones. Among spontaneous mutations, A:T and G:C pairs were equally subjected to mutations, whereas the substitutions from G:C pairs and those to A:T pairs predominated among those induced with soft X-rays. The peak-energy X-rays were more effective in killing and causing mutations than the low-energy X-rays, however, there seemed no base-change events uniquely attributable to phosphorus K-shell absorption. (author)

  12. Energy-angle correlation correction algorithm for monochromatic computed tomography based on Thomson scattering X-ray source

    Science.gov (United States)

    Chi, Zhijun; Du, Yingchao; Huang, Wenhui; Tang, Chuanxiang

    2017-12-01

    The necessity for compact and relatively low cost x-ray sources with monochromaticity, continuous tunability of x-ray energy, high spatial coherence, straightforward polarization control, and high brightness has led to the rapid development of Thomson scattering x-ray sources. To meet the requirement of in-situ monochromatic computed tomography (CT) for large-scale and/or high-attenuation materials based on this type of x-ray source, there is an increasing demand for effective algorithms to correct the energy-angle correlation. In this paper, we take advantage of the parametrization of the x-ray attenuation coefficient to resolve this problem. The linear attenuation coefficient of a material can be decomposed into a linear combination of the energy-dependent photoelectric and Compton cross-sections in the keV energy regime without K-edge discontinuities, and the line integrals of the decomposition coefficients of the above two parts can be determined by performing two spectrally different measurements. After that, the line integral of the linear attenuation coefficient of an imaging object at a certain interested energy can be derived through the above parametrization formula, and monochromatic CT can be reconstructed at this energy using traditional reconstruction methods, e.g., filtered back projection or algebraic reconstruction technique. Not only can monochromatic CT be realized, but also the distributions of the effective atomic number and electron density of the imaging object can be retrieved at the expense of dual-energy CT scan. Simulation results validate our proposal and will be shown in this paper. Our results will further expand the scope of application for Thomson scattering x-ray sources.

  13. Effects of the chromatic defocus caused by interchange of two monochromatic lights on refraction and ocular dimension in guinea pigs.

    Science.gov (United States)

    Qian, Yi-Feng; Dai, Jin-Hui; Liu, Rui; Chen, Min-Jie; Zhou, Xing-Tao; Chu, Ren-Yuan

    2013-01-01

    To investigate refractive and axial responses to the shift of focal plane resulting from the interchange of two monochromatic lights separately corresponding to the peak wavelengths of the cones absorption spectrum in retina, fifty 2-week-old pigmented guinea pigs were randomly assigned to five groups based on the mode of illumination: short-wavelength light (SL), middle-wavelength light (ML) and broad-band white light (BL) for 20 weeks, SL for 10 weeks followed by ML for 10 weeks (STM), as well as ML for 10 weeks followed by SL for 10 weeks (MTS). Biometric and refractive measurements were then performed every 2 weeks. After 10 weeks, SL and STM groups became more hyperopic and had less vitreous elongation than BL group. However, ML and MTS groups became more myopic and had more vitreous elongation. After interchange of the monochromatic light, the refractive error decreased rapidly by about 1.93D and the vitreous length increased by 0.14 mm in STM group from 10 to 12 weeks. After that, there were no significant intergroup differences between STM and BL groups. The interchange from ML to SL quickly increased the refractive error by about 1.53D and decreased the vitreous length by about 0.13 mm in MTS group after two weeks. At this time, there were also no significant intergroup differences between MTS and BL groups. The guinea pig eye can accurately detect the shift in focal plane caused by interchange of two monochromatic lights and rapidly generate refractive and axial responses. However, an excessive compensation was induced. Some properties of photoreceptors or retina may be changed by the monochromatic light to influence the following refractive development.

  14. Effects of the chromatic defocus caused by interchange of two monochromatic lights on refraction and ocular dimension in guinea pigs.

    Directory of Open Access Journals (Sweden)

    Yi-Feng Qian

    Full Text Available To investigate refractive and axial responses to the shift of focal plane resulting from the interchange of two monochromatic lights separately corresponding to the peak wavelengths of the cones absorption spectrum in retina, fifty 2-week-old pigmented guinea pigs were randomly assigned to five groups based on the mode of illumination: short-wavelength light (SL, middle-wavelength light (ML and broad-band white light (BL for 20 weeks, SL for 10 weeks followed by ML for 10 weeks (STM, as well as ML for 10 weeks followed by SL for 10 weeks (MTS. Biometric and refractive measurements were then performed every 2 weeks. After 10 weeks, SL and STM groups became more hyperopic and had less vitreous elongation than BL group. However, ML and MTS groups became more myopic and had more vitreous elongation. After interchange of the monochromatic light, the refractive error decreased rapidly by about 1.93D and the vitreous length increased by 0.14 mm in STM group from 10 to 12 weeks. After that, there were no significant intergroup differences between STM and BL groups. The interchange from ML to SL quickly increased the refractive error by about 1.53D and decreased the vitreous length by about 0.13 mm in MTS group after two weeks. At this time, there were also no significant intergroup differences between MTS and BL groups. The guinea pig eye can accurately detect the shift in focal plane caused by interchange of two monochromatic lights and rapidly generate refractive and axial responses. However, an excessive compensation was induced. Some properties of photoreceptors or retina may be changed by the monochromatic light to influence the following refractive development.

  15. Monochromatic Spectral Computed Tomography with Low Iodine Concentration Contrast Medium in a Rabbit VX2 Liver Model:: Investigation of Image Quality and Detection Rate.

    Science.gov (United States)

    Zhou, Yue; Xu, Han; Hou, Ping; Dong, Jun Q; Wang, Ming Y; Gao, Jian B

    2016-04-01

    This study aimed to validate the feasibility of using virtual monochromatic spectral computed tomography (CT) with isotonic low iodine concentration contrast medium for VX2 hepatic tumors. Sixty New Zealand white rabbits with implanted VX2 hepatic tumors underwent two-phase contrast-enhanced spectral CT imaging on the 14th day after tumor implantation. They were randomly divided into groups A, B, and C, with 20 rabbits each (group A: 270 mg I/mL, monochromatic spectral images; group B: 370 mg I/mL, conventional 120 kVp images, 100% filtered back projection [FBP]; group C: 270 mg I/mL, conventional 120 kVp images, 100% FBP). Group A was further divided into two subgroups (subgroup A1: 100% FBP; subgroup A2: 50% FBP + 50% adaptive statistical iterative reconstruction). Objective evaluation (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], and image noise), subjective rating score (image noise score, anatomical details score, overall image quality score, and lesion conspicuity score), CT dose index volume, and dose length product were compared between groups during two-phase contrast enhancement. The detection rates of the four groups were calculated as percentages. Image noise (SNR and CNR) among the four groups was statistically significant (P noise in group A2 was lower than in group A1, but higher than that in groups B and C (P noise score of group A2 was higher than that of the other three groups. In terms of the anatomic details score, the overall image quality score, and the lesion conspicuity score, the images of group A2 were superior to that of groups A1 and C. For hepatic tumor diameters more than or equal to 1.0 cm and less than 3.0 cm, group A achieved a higher detection rate than groups B and C. The CT dose index volume, dose length product, and effective dose in group A were significantly lower than that in groups B and C (P noise, increase detection rate for small tumors, and decrease radiation dose and iodine load in

  16. Impact of curcumin supplementation in monochromatic light on lipid serum profile of sexually mature female Magelang ducks

    Directory of Open Access Journals (Sweden)

    K. Kasiyati

    2018-03-01

    Full Text Available An experiment was conducted to study the effect of curcumin supplementation inexpose monochromatic light on serum lipid concentrations of sexually mature female magelang duck. One hundred and ninety two female magelang ducks were assigned into a completely randomized design with a 4×4 factorial arrangement and each experimental unit was repeated 3 times, each with 4 female magelang ducks. The first factor was dose of curcumin supplementation consisted of 4 levels i.e., 0, 9, 18, and 36 mg/duck/day. The second factor was the color of monochromatic light consisted of 4 levels i.e., white, red, green, and blue colors. The data were analyzed by two-way ANOVA. The result showed that serum concentrations of triglyceride, cholesterol, very low density lipoprotein (VLDL, and low density lipoprotein (LDL were lower (P<0.05 while high density lipoprotein (HDL were higher (P<0.05 in experimental ducks supplemented with a curcumin dose of 36 mg/duck/day in variety of monochromatic light colors compared to control experimental ducks without curcumin supplementation. The curcumin doses of 18 or 36 mg/duck/day within red, green, or blue light had the potential to modulate lipid metabolism, as indicated by the increased serum concentration of HDL and the decreased serum concentrations of triglyceride, cholesterol, VLDL, and LDL of the experimental female magelang ducks.

  17. Photofission of {sup NAT} Pt by monochromatic and polarized photons in the quasi-deuteron region; Fotofissao da {sup NAT} Pt por fotons monocromaticos e polarizados na regiao do quase-deuteron

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Eduardo de

    1992-01-01

    The measurement of the Nat Pt photofission yield at 69 MeV of effective average energy of the incident photon is made using a polarized and monochromatic photon beam from the LADON system of the National Laboratory of Frascati, Italy, produced by inverse Compton scattering of laser light by high energy electrons of the ADONE Accelerator and using as fission track solid detector the Makrofol, being the developing made by usual procedure. The experimental value of the nuclear fissionability is compared to a theoretical value obtained following a model at two stages: in the first, the photon energy is absorbed by a neutron-proton pair inducing to the nucleus excitation, and in the second the nucleus de-excites due to the competition between nucleon evaporation and fission. The effect of fast nucleon emission during the first stage and the successive evaporation of neutrons in the second stage are considered. 40 refs, 12 figs, 9 tabs.

  18. Biologically based analysis of lung cancer incidence in a large Canadian occupational cohort with low-LET low-dose radiation exposure, and comparison with Japanese atomic bomb survivors

    International Nuclear Information System (INIS)

    Hazelton, W.D.; Curtis, S.B.; Moolgavkar, S.H.; Hutchinson, F.; Krewski, D.

    2003-01-01

    Lung cancer incidence is analyzed in a large Canadian National Dose Registry (CNDR) cohort with individual annual dosimetry for low-dose occupational exposure to gamma and tritium radiation using several types of multistage models. The primary analysis utilizes the two-stage clonal expansion model (TSCE), with sensitivity analyses using extensions of this model incorporating additional stages. Characteristic and distinct temporal patterns of risk are found for dose-response affecting early, middle, or late stages of carcinogenesis, e.g. initiation with one or more stages, clonal expansion, or malignant conversion. Fixed lag or lag distributions are used to model time from first malignant cell to incidence. Background rates are analyzed by gender, job classification and birth cohort. Lacking individual smoking data, surrogate doses based on US annual per capita cigarette consumption appear to account for much of the birth cohort effect. Males, with mean cumulative exposure for gamma and tritium of 11.5 mSv and 322 incident lung cancer cases have a significant dose-response with 33 cases attributable to radiation. Female dose-response, with mean cumulative exposure of 1.7 mSv and 78 incident cases, appears similar but is not statistically significant. Findings for males include an inverse-dose-rate effect (increased risk with protraction of a given dose) and dose-response effects on initiation, promotion and malignant conversion, although the effect on initiation is not statistically significant. The excess relative risk (ERR) and excess absolute risk (EAR) depend on age at exposure, duration, dose, and age at follow-up. The ERR increases with dose, tapering off at higher doses, making a plot of ERR against dose concave-downward, similar to apparent low-dose results seen below 1 Sv for solid tumor mortality of atomic bomb survivors. The concave-downward trend of ERR and the inverse-dose-rate effect are both counter to prevailing beliefs about effects of low

  19. Radiation injury

    International Nuclear Information System (INIS)

    Hubner, K.F.

    1988-01-01

    Radiation accidents and incidents continue to be of great interest and concern to the public. Issues such as the threat of nuclear war, the Chernobyl reactor accident, or reports of sporadic incidences of accidental radiation exposure keep this interest up and maintain a high level of fear among the public. In this climate of real concern and radiation phobia, physicians should not only be prepared to answer questions about acute or late effects of ionizing radiation, but also be able to participate in the initial assessment and management of individuals who have been exposed to ionizing radiation or contaminated with radioactive material. Some of the key facts about radiation injury and its medical treatment are discussed by the author

  20. SU-D-BRA-06: Dual-Energy Chest CT: The Effects of Virtual Monochromatic Reconstructions On Texture Analysis Features

    International Nuclear Information System (INIS)

    Sorensen, J; Duran, C; Stingo, F; Wei, W; Rao, A; Zhang, L; Court, L; Erasmus, J; Godoy, M

    2015-01-01

    Purpose: To characterize the effect of virtual monochromatic reconstructions on several commonly used texture analysis features in DECT of the chest. Further, to assess the effect of monochromatic energy levels on the ability of these textural features to identify tissue types. Methods: 20 consecutive patients underwent chest CTs for evaluation of lung nodules using Siemens Somatom Definition Flash DECT. Virtual monochromatic images were constructed at 10keV intervals from 40–190keV. For each patient, an ROI delineated the lesion under investigation, and cylindrical ROI’s were placed within 5 different healthy tissues (blood, fat, muscle, lung, and liver). Several histogram- and Grey Level Cooccurrence Matrix (GLCM)-based texture features were then evaluated in each ROI at each energy level. As a means of validation, these feature values were then used in a random forest classifier to attempt to identify the tissue types present within each ROI. Their predictive accuracy at each energy level was recorded. Results: All textural features changed considerably with virtual monochromatic energy, particularly below 70keV. Most features exhibited a global minimum or maximum around 80keV, and while feature values changed with energy above this, patient ranking was generally unaffected. As expected, blood demonstrated the lowest inter-patient variability, for all features, while lung lesions (encompassing many different pathologies) exhibited the highest. The accuracy of these features in identifying tissues (76% accuracy) was highest at 80keV, but no clear relationship between energy and classification accuracy was found. Two common misclassifications (blood vs liver and muscle vs fat) accounted for the majority (24 of the 28) errors observed. Conclusion: All textural features were highly dependent on virtual monochromatic energy level, especially below 80keV, and were more stable above this energy. However, in a random forest model, these commonly used features were

  1. SU-D-BRA-06: Dual-Energy Chest CT: The Effects of Virtual Monochromatic Reconstructions On Texture Analysis Features

    Energy Technology Data Exchange (ETDEWEB)

    Sorensen, J; Duran, C; Stingo, F; Wei, W; Rao, A; Zhang, L; Court, L; Erasmus, J; Godoy, M [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To characterize the effect of virtual monochromatic reconstructions on several commonly used texture analysis features in DECT of the chest. Further, to assess the effect of monochromatic energy levels on the ability of these textural features to identify tissue types. Methods: 20 consecutive patients underwent chest CTs for evaluation of lung nodules using Siemens Somatom Definition Flash DECT. Virtual monochromatic images were constructed at 10keV intervals from 40–190keV. For each patient, an ROI delineated the lesion under investigation, and cylindrical ROI’s were placed within 5 different healthy tissues (blood, fat, muscle, lung, and liver). Several histogram- and Grey Level Cooccurrence Matrix (GLCM)-based texture features were then evaluated in each ROI at each energy level. As a means of validation, these feature values were then used in a random forest classifier to attempt to identify the tissue types present within each ROI. Their predictive accuracy at each energy level was recorded. Results: All textural features changed considerably with virtual monochromatic energy, particularly below 70keV. Most features exhibited a global minimum or maximum around 80keV, and while feature values changed with energy above this, patient ranking was generally unaffected. As expected, blood demonstrated the lowest inter-patient variability, for all features, while lung lesions (encompassing many different pathologies) exhibited the highest. The accuracy of these features in identifying tissues (76% accuracy) was highest at 80keV, but no clear relationship between energy and classification accuracy was found. Two common misclassifications (blood vs liver and muscle vs fat) accounted for the majority (24 of the 28) errors observed. Conclusion: All textural features were highly dependent on virtual monochromatic energy level, especially below 80keV, and were more stable above this energy. However, in a random forest model, these commonly used features were

  2. Ionizing radiations

    International Nuclear Information System (INIS)

    Newton, W.

    1984-01-01

    The purpose of this article is to simplify some of the relevant points of legislation, biological effects and protection for the benefit of the occupational health nurse not familiar with the nuclear industries. The subject is dealt with under the following headings; Understanding atoms. What is meant by ionizing radiation. Types of ionizing radiation. Effects of radiation: long and short term somatic effects, genetic effects. Control of radiation: occupational exposure, women of reproductive age, medical aspects, principles of control. The occupational health nurse's role. Emergency arrangements: national arrangements for incidents involving radiation, action to be taken by the nurse. Decontamination procedures: external and internal contamination. (U.K.)

  3. Radiation imaging

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.

    1986-05-21

    A detector for the detection of radiation such as X-ray radiation comprises an array of scintillation elements embedded in a sheet of radiation absorbing material. The scintillation elements are monitored individually, for example by a corresponding array of photodiodes, to build up a picture of the incident radiation. The front face of the sheet and the inner walls of the bores may be coated with a reflective material. The detector finds particular application in weld radiography. The detector may be stepped relative to the radiation source, the signals produced by the rows of the detector as they pass a predetermined point being summed.

  4. Radiation imaging

    International Nuclear Information System (INIS)

    Redmayne, Ian.

    1986-01-01

    A detector for the detection of radiation such as X-ray radiation comprises an array of scintillation elements embedded in a sheet of radiation absorbing material. The scintillation elements are monitored individually, for example by a corresponding array of photodiodes, to build up a picture of the incident radiation. The front face of the sheet and the inner walls of the bores may be coated with a reflective material. The detector finds particular application in weld radiography. The detector may be stepped relative to the radiation source, the signals produced by the rows of the detector as they pass a predetermined point being summed. (author)

  5. Monochromatic filter with multiple manipulation approaches by the layered all-dielectric patch array

    International Nuclear Information System (INIS)

    Liu, Xiaoshan; Liu, Guiqiang; Fu, Guolan; Liu, Mulin; Liu, Zhengqi

    2016-01-01

    Monochromatic filtering with ultra-narrowband and high spectral contrast is desirable for wide applications in display, image, and other optoelectronics. However, owing to the inherent omhic losses in the metallic materials, a broadband spectrum with a low Q-factor down to 10 inevitably limits the device performance. Herein, we for the first time theoretically propose and demonstrate an ultra-narrowband color-filtering platform based on the layered all-dielectric meta-material (LADM), which consists of a triple-layer high/low/high-index dielectrics cavity structure. Owing to the lossless dielectric materials used, sharp resonances with the bandwidth down to sub-10 nm are observed in the sub-wavelength LADM-based filters. A spectral Q-factor of 361.6 is achieved, which is orders of magnitude larger than that of the plasmonic resonators. Moreover, for the other significant factor for evaluation of filtering performance, the spectral contrast reaches 94.5%. These optical properties are the main results of the excitation of the resonant modes in the LADMs. Furthermore, polarization-manipulated light filtering is realized in this LADM. The classical Malus law is also confirmed in the reflective spectrum by tuning the polarization state. More interestingly and importantly, the filtering phenomenon shows novel features of the wavelength-independent and tunable resonant intensity for the reflective spectrum when the LADM-based filter is illuminated under an oblique state. High scalability of the sharp reflective spectrum is obtained by tuning the structural parameters. A single-wavelength reflective filtering window is also achieved in the visible frequencies. These features hold promise for the LADM-based filter with wide applications in color engineering, displaying, imaging, etc. (paper)

  6. Effect of monochromatic light on circadian rhythmic expression of clock genes in the hypothalamus of chick.

    Science.gov (United States)

    Jiang, Nan; Wang, Zixu; Cao, Jing; Dong, Yulan; Chen, Yaoxing

    2017-08-01

    To clarify the effect of monochromatic light on circadian clock gene expression in chick hypothalamus, a total 240 newly hatched chickens were reared under blue light (BL), green light (GL), red light (RL) and white light (WL), respectively. On the post-hatched day 14, 24-h profiles of seven core clock genes (cClock, cBmal1, cBmal2, cCry1, cCry2, cPer2 and cPer3) were measured at six time points (CT 0, CT 4, CT 8, CT 12, CT 16, CT 20, circadian time). We found all these clock genes expressed with a significant rhythmicity in different light wavelength groups. Meanwhile, cClock and cBmal1 showed a high level under GL, and followed a corresponding high expression of cCry1. However, RL decreased the expression levels of these genes. Be consistent with the mRNA level, CLOCK and BMAL1 proteins also showed a high level under GL. The CLOCK-like immunoreactive neurons were observed not only in the SCN, but also in the non-SCN brain region such as the nucleus anterior medialis hypothalami, the periventricularis nucleus, the paraventricular nucleus and the median eminence. All these results are consistent with the auto-regulatory circadian feedback loop, and indicate that GL may play an important role on the circadian time generation and development in the chick hypothalamus. Our results also suggest that the circadian clock in the chick hypothalamus such as non-SCN brain region were involved in the regulation of photo information. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Monochromatic green light induces an aberrant accumulation of geranylgeranyled chlorophylls in plants.

    Science.gov (United States)

    Materová, Zuzana; Sobotka, Roman; Zdvihalová, Barbora; Oravec, Michal; Nezval, Jakub; Karlický, Václav; Vrábl, Daniel; Štroch, Michal; Špunda, Vladimír

    2017-07-01

    Light quality is an important environmental factor affecting the biosynthesis of photosynthetic pigments whose production seems to be affected not only quantitatively but also qualitatively. In this work, we set out to identify unusual pigment detected in leaves of barley (Hordeum vulgare L.) and explain its presence in plants grown under monochromatic green light (GL; 500-590 nm). The chromatographic analysis (HPLC-DAD) revealed that a peak belonging to this unknown pigment is eluted between chlorophyll (Chl) a and b. This pigment exhibited the same absorption spectrum and fluorescence excitation and emission spectra as Chl a. It was negligible in control plants cultivated under white light of the same irradiance (photosynthetic photon flux density of 240 μmol m -2  s -1 ). Mass spectrometry analysis of this pigment (ions m/z = 889 [M-H] - ; m/z = 949 [M+acetic acid-H] - ) indicates that it is Chl a with a tetrahydrogengeranylgeraniol side chain (containing two double bonds in a phytyl side chain; Chl a THGG ), which is an intermediate in Chl a synthesis. In plants grown under GL, the proportion of Chl a THGG to total Chl content rose to approximately 8% and 16% after 7 and 14 days of cultivation, respectively. Surprisingly, plants cultivated under GL exhibited drastically increased concentration of the enzyme geranylgeranyl reductase, which is responsible for the reduction of phytyl chain double bonds in the Chl synthesis pathway. This indicates impaired activity of this enzyme in GL-grown plants. A similar effect of GL on Chl synthesis was observed for distinct higher plant species. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Melatonin modulates monochromatic light-induced melatonin receptor expression in the hypothalamus of chicks.

    Science.gov (United States)

    Zhang, Liwei; Chen, Funing; Cao, Jing; Dong, Yulan; Wang, Zixu; Chen, Yaoxing

    2017-09-01

    To study the mechanism of the effect of monochromatic light on physiological function in chicken, a total of 192 newly hatched chicks were randomly divided into intact, sham-operated and pinealectomy groups then exposed to white light (WL), red light (RL), green light (GL) and blue light (BL) using a light-emitting diode (LED) system for two weeks. At P14, the hypothalami were immediately collected for immunohistochemical staining of melatonin receptor subtypes (Mel1a and Mel1b) and detection of Mel1a and Mel1b expressions using RT-PCR and western blot. Immunohistochemical staining of the hypothalamus showed that the Mel1a-ir cells were distributed in the preoptic area (POA), nucleus preopticus periventricularis (POP) and suprachiasmatic nuclei (SCN), and the Mel1b-ir cells were presented in the POA and SCN. Analysis of RT-PCR and western blot showed that the mRNA and protein levels of Mel1a and Mel1b in the hypothalamus of chick exposed to GL were increased by 10.7-29.3%, 9.18-35.9% and 8.97-27.3% compared to those in the chicks exposed to WL (P=0.029-0.002), RL (P=0.027-0.001) and BL (P=0.038-0.007) in the intact group, respectively. After pinealectomy, however, these parameters decreased and there were no significant differences among the WL, RL, GL and BL groups. These findings suggested that melatonin plays a critical role in GL illumination-enhanced Mel1a and Mel1b expressions in the hypothalamus of chicks. Copyright © 2017 Elsevier GmbH. All rights reserved.

  9. A monochromatic, aberration-corrected, dual-beam low energy electron microscope.

    Science.gov (United States)

    Mankos, Marian; Shadman, Khashayar

    2013-07-01

    The monochromatic, aberration-corrected, dual-beam low energy electron microscope (MAD-LEEM) is a novel instrument aimed at imaging of nanostructures and surfaces at sub-nanometer resolution that includes a monochromator, aberration corrector and dual beam illumination. The monochromator reduces the energy spread of the illuminating electron beam, which significantly improves spectroscopic and spatial resolution. The aberration corrector utilizes an electron mirror with negative aberrations that can be used to compensate the aberrations of the LEEM objective lens for a range of electron energies. Dual flood illumination eliminates charging generated when a conventional LEEM is used to image insulating specimens. MAD-LEEM is designed for the purpose of imaging biological and insulating specimens, which are difficult to image with conventional LEEM, Low-Voltage SEM, and TEM instruments. The MAD-LEEM instrument can also be used as a general purpose LEEM with significantly improved resolution. The low impact energy of the electrons is critical for avoiding beam damage, as high energy electrons with keV kinetic energies used in SEMs and TEMs cause irreversible change to many specimens, in particular biological materials. A potential application for MAD-LEEM is in DNA sequencing, which demands imaging techniques that enable DNA sequencing at high resolution and speed, and at low cost. The key advantages of the MAD-LEEM approach for this application are the low electron impact energies, the long read lengths, and the absence of heavy-atom DNA labeling. Image contrast simulations of the detectability of individual nucleotides in a DNA strand have been developed in order to refine the optics blur and DNA base contrast requirements for this application. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Incidence of radiation-induced Graves' disease in patients treated with radioiodine for thyroid autonomy before and after introduction of a high-sensitivity TSH receptor antibody assay

    Energy Technology Data Exchange (ETDEWEB)

    Dunkelmann, Simone; Wolf, Ricarda; Koch, Annedore; Kittner, Christian; Groth, Peter; Schuemichen, Carl [University of Rostock, Clinic of Nuclear Medicine, Rostock (Germany)

    2004-10-01

    Autoimmune hyperthyroidism may occur several months after radioiodine therapy (RIT) for functional thyroid autonomy. Exacerbation of pre-existing subclinical Graves' disease (GD) has been held responsible for this phenomenon. Determination of TSH receptor antibody using solubilised porcine epithelial cell membranes is insensitive and may have failed to diagnose GD in these patients before RIT. Following the introduction of a more sensitive assay, using the human TSH receptor as an antigen, it has been expected that the incidence of radiation-induced GD after RIT for functional thyroid autonomy will be reduced. In a first group of 1,428 patients treated between November 1993 and March 1997 (group I) we used the porcine TRAb assay to exclude GD, while in a second group comprising 1,408 patients treated between January 2000 and December 2001 (group II), GD was excluded using the human TRAb assay. A matched control group of 231 patients was derived from group II. In group I a total of 15 (1.05%) patients developed obvious or suspected radiation-induced GD, while in group II 17 (1.2%) did so; the interval until development of GD was 8.4 and 8.8 months, respectively, after RIT. Serum anti-thyroid peroxidase levels before RIT were elevated in 36.4% of group I patients and 47.1% of group II patients, but in only 5.6% of the control group. Other non-specific signs of mild immunopathy of the thyroid were seen retrospectively in 73.3%, 64.7% and 16.0% of the patients in these three groups, respectively. In conclusion, the introduction of a high-sensitivity TRAb assay did not reduce the incidence of autoimmune hyperthyroidism occurring late after RIT for functional thyroid autonomy, but mild immunopathy of the thyroid is seen more frequently in these patients and seems to be a predisposing factor in the development of radiation-induced GD. (orig.)

  11. The protection of operating personnel in nuclear power plants against the risk of nuclear incidents and ionizing radiation arising from normal operation of the plant. Rules and problems

    International Nuclear Information System (INIS)

    Ortore, F.; Scalera, D.

    1980-03-01

    After an analysis of the nuclear third party liability insurance policy to be taken out in Italy in implementation of Act no. 1860 of 31 December 1962 and Decree No. 519 of 10 May 1979, the collective policy against radiation injuries taken out for operating personnel in nuclear installations is described. The author is in favour of further harmonization of the legal system presently in force in this respect. (NEA) [fr

  12. The incidence of unstable chromosome aberrations in peripheral blood lymphocytes from occupationally exposed people in Boris Kidric Institute of nuclear sciences (Radiation protection department)

    Energy Technology Data Exchange (ETDEWEB)

    Zunic, Z; Markovic, S; Bajic, V; Milic, O; Radotic, N; Horvat, Dj; Nikolic, M; Lakoski, A [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1989-07-01

    The results of the chromosome analysis of 17 employees of Radiation protection department of Boris Kidric Institute of Nuclear Sciences were related to the corresponding values of thermoluminescence dosimetry (TLD) measurements within the past eight years. The results obtained show the biological effects (structural chromosome aberrations) of chronic of fractionated exposures, low-level acute doses, even in the cases when the individual cumulative equivalent doses were 10 times lower than the order of maximum permissible occupational exposures (author)

  13. Assessment of ionizing radiation as a risk factor for breast cancer incidence in Goiania; Avaliacao da radiacao ionizante como fator de risco para a incidencia de cancer de mama em Goiania

    Energy Technology Data Exchange (ETDEWEB)

    Lage, Leonardo Bastos

    2016-11-01

    This research aims to evaluate whether exposure to ionizing radiation to which women are subjected can be associated with the incidence of breast cancer in Goiania. The defined study area is the central region of Goiania, or the Sanitary Districts of Campinas-Centro and Sul, in which are the seven major accident sources of contamination with Cesium 137, and also, as shown by previous study, the majority of new cases of breast cancer (60,43 %). We used the geographical division of the city in census tracts and health districts. The data collection was divided in two stages: the first, for the survey of radiometric measurements, and the second, for identifying the addresses of women diagnosed with breast cancer. The radiometric survey occurred between 2010 and 2014, in which was used an environmental gamma radiation mobile measuring system. This system was composed by a high-sensitivity detector coupled to a Global Positioning System (GPS) and a microcomputer. The assembly was installed on a motor vehicle so that the height of the detector is found at one meter from the ground, and programmed to obtain a measurement of the doses absorbed in the air rate each second. The data collected were: doses absorbed in the air rate, geographical coordinates, altitude, date and time of acquisition. From Mobisys software, files were generated and from ArcGIS 10.0 platform, geospatial assessment survey through the elaboration of thematic maps and geospatial analysis statistics. The annual averages of effective doses and collective effective doses were estimated from the rate of doses absorbed in air collected by the system and the resident population in the census tracts. The second stage begun from the data collection at the Registry of Goiania's Population Based Cancer (RCBPGO), in which were identified addresses of women diagnosed with breast cancer between 2001 and 2010. Part of the data was geographically referenced and using census data were estimated and compared the

  14. Reversal of diabetic peripheral neuropathy and new wound incidence: the role of MIRE.

    Science.gov (United States)

    Powell, Mark W; Carnegie, Dale E; Burke, Thomas J

    2004-01-01

    To determine if improved foot sensitivity to the Semmes-Weinstein 10-g (5.07) monofilament, originally impaired because of diabetic peripheral neuropathy, might be associated with a reduced incidence of new diabetic foot wounds. Retrospective cohort study using a health status questionnaire. Sixty-eight individuals over age 64 with diabetes, diabetic peripheral neuropathy, and loss of protective sensation who had clinically demonstrable increases in foot sensation to the Semmes-Weinstein monofilament after treatment with monochromatic near infrared photo energy. After reversal of diabetic peripheral neuropathy following treatment with monochromatic near infrared photo energy, only 1 of 68 patients developed a new diabetic foot wound, for an incidence of 1.5%. Comparatively, the incidence previously reported in the Medicare-aged population with diabetes was 7.3%. Improved foot sensitivity to the Semmes-Weinstein monofilament in patients previously suffering from loss of protective sensation due to diabetic neuropathy appears to be associated with a lower incidence of new diabetic foot ulcers when compared with the expected incidence in the Medicare-aged population with diabetes. Therapeutic interventions that effectively improve foot sensitivity that has been previously diminished due to diabetic peripheral neuropathy may substantially reduce the incidence of new foot wounds in the Medicare-aged population with diabetes.

  15. Incidence and Predictive Factors of Pain Flare After Spine Stereotactic Body Radiation Therapy: Secondary Analysis of Phase 1/2 Trials

    International Nuclear Information System (INIS)

    Pan, Hubert Y.; Allen, Pamela K.; Wang, Xin S.; Chang, Eric L.; Rhines, Laurence D.; Tatsui, Claudio E.; Amini, Behrang; Wang, Xin A.; Tannir, Nizar M.; Brown, Paul D.; Ghia, Amol J.

    2014-01-01

    Purpose/Objective(s): To perform a secondary analysis of institutional prospective spine stereotactic body radiation therapy (SBRT) trials to investigate posttreatment acute pain flare. Methods and Materials: Medical records for enrolled patients were reviewed. Study protocol included baseline and follow-up surveys with pain assessment by Brief Pain Inventory and documentation of pain medications. Patients were considered evaluable for pain flare if clinical note or follow-up survey was completed within 2 weeks of SBRT. Pain flare was defined as a clinical note indicating increased pain at the treated site or survey showing a 2-point increase in worst pain score, a 25% increase in analgesic intake, or the initiation of steroids. Binary logistic regression was used to determine predictive factors for pain flare occurrence. Results: Of the 210 enrolled patients, 195 (93%) were evaluable for pain flare, including 172 (88%) clinically, 135 (69%) by survey, and 112 (57%) by both methods. Of evaluable patients, 61 (31%) had undergone prior surgery, 57 (29%) had received prior radiation, and 34 (17%) took steroids during treatment, mostly for prior conditions. Pain flare was observed in 44 patients (23%). Median time to pain flare was 5 days (range, 0-20 days) after the start of treatment. On multivariate analysis, the only independent factor associated with pain flare was the number of treatment fractions (odds ratio = 0.66, P=.004). Age, sex, performance status, spine location, number of treated vertebrae, prior radiation, prior surgery, primary tumor histology, baseline pain score, and steroid use were not significant. Conclusions: Acute pain flare after spine SBRT is a relatively common event, for which patients should be counseled. Additional study is needed to determine whether prophylactic or symptomatic intervention is preferred

  16. Incidence and Predictive Factors of Pain Flare After Spine Stereotactic Body Radiation Therapy: Secondary Analysis of Phase 1/2 Trials

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Hubert Y.; Allen, Pamela K. [Department of Radiation Oncology, University of Texas MD Anderson Cancer, Houston, Texas (United States); Wang, Xin S. [Department of Symptom Research, University of Texas MD Anderson Cancer, Houston, Texas (United States); Chang, Eric L. [Department of Radiation Oncology, University of Texas MD Anderson Cancer, Houston, Texas (United States); Department of Radiation Oncology, USC Norris Cancer Center, Los Angeles, California (United States); Rhines, Laurence D.; Tatsui, Claudio E. [Department of Neurosurgery, University of Texas MD Anderson Cancer, Houston, Texas (United States); Amini, Behrang [Department of Diagnostic Radiology, University of Texas MD Anderson Cancer, Houston, Texas (United States); Wang, Xin A. [Department of Radiation Physics, University of Texas MD Anderson Cancer, Houston, Texas (United States); Tannir, Nizar M. [Department of Genitourinary Medical Oncology, University of Texas MD Anderson Cancer, Houston, Texas (United States); Brown, Paul D. [Department of Radiation Oncology, University of Texas MD Anderson Cancer, Houston, Texas (United States); Ghia, Amol J., E-mail: AJGhia@mdanderson.org [Department of Radiation Oncology, University of Texas MD Anderson Cancer, Houston, Texas (United States)

    2014-11-15

    Purpose/Objective(s): To perform a secondary analysis of institutional prospective spine stereotactic body radiation therapy (SBRT) trials to investigate posttreatment acute pain flare. Methods and Materials: Medical records for enrolled patients were reviewed. Study protocol included baseline and follow-up surveys with pain assessment by Brief Pain Inventory and documentation of pain medications. Patients were considered evaluable for pain flare if clinical note or follow-up survey was completed within 2 weeks of SBRT. Pain flare was defined as a clinical note indicating increased pain at the treated site or survey showing a 2-point increase in worst pain score, a 25% increase in analgesic intake, or the initiation of steroids. Binary logistic regression was used to determine predictive factors for pain flare occurrence. Results: Of the 210 enrolled patients, 195 (93%) were evaluable for pain flare, including 172 (88%) clinically, 135 (69%) by survey, and 112 (57%) by both methods. Of evaluable patients, 61 (31%) had undergone prior surgery, 57 (29%) had received prior radiation, and 34 (17%) took steroids during treatment, mostly for prior conditions. Pain flare was observed in 44 patients (23%). Median time to pain flare was 5 days (range, 0-20 days) after the start of treatment. On multivariate analysis, the only independent factor associated with pain flare was the number of treatment fractions (odds ratio = 0.66, P=.004). Age, sex, performance status, spine location, number of treated vertebrae, prior radiation, prior surgery, primary tumor histology, baseline pain score, and steroid use were not significant. Conclusions: Acute pain flare after spine SBRT is a relatively common event, for which patients should be counseled. Additional study is needed to determine whether prophylactic or symptomatic intervention is preferred.

  17. Risk of cancer incidence before the age of 15 years after exposure to ionising radiation from computed tomography: results from a German cohort study

    Energy Technology Data Exchange (ETDEWEB)

    Krille, L. [University Medical Center Mainz, Institute of Medical Biostatistics, Epidemiology and Informatics, Mainz (Germany); International Agency for Research on Cancer, Lyon (France); Dreger, S.; Zeeb, H. [University of Bremen, Leibniz - Institute for Prevention Research and Epidemiology - BIPS, Research Focus Health Sciences Bremen, Bremen (Germany); Schindel, R.; Blettner, M. [University Medical Center Mainz, Institute of Medical Biostatistics, Epidemiology and Informatics, Mainz (Germany); Albrecht, T. [Vivantes, Klinikum Neukoelln, Institut fuer Radiologie und Interventionelle Therapie, Berlin (Germany); Asmussen, M. [Zentralinstitut fuer Bildgebende Diagnostik, Staedtisches Klinikum Karlsruhe, Karlsruhe (Germany); Barkhausen, J. [Universitaetsklinikum Schleswig Holstein, Klinik fuer Radiologie und Nuklearmedizin, Campus Luebeck, Luebeck (Germany); Berthold, J.D. [Medizinische Hochschule Hannover, Institut fuer Diagnostische und Interventionelle Radiologie, Hannover (Germany); Chavan, A. [Klinikum Oldenburg GmbH, Institut fuer Diagnostische and Interventionelle Radiologie, Oldenburg (Germany); Claussen, C. [Universitaetsklinikum Tuebingen, Abt. fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Forsting, M. [Universitaetsklinikum Essen, Institut fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Essen (Germany); Gianicolo, E.A.L. [University Medical Center Mainz, Institute of Medical Biostatistics, Epidemiology and Informatics, Mainz (Germany); National Research Council, Institute of Clinical Physiology, Lecce (Italy); Jablonka, K. [Klinikum Bremen-Mitte, Klinik fuer Radiologische Diagnostik und Nuklearmedizin, Bremen (Germany); Jahnen, A. [Centre de Recherche Public Henri Tudor, Luxembourg (Luxembourg); Langer, M. [Universitaetsklinikum Freiburg, Klinik fuer Radiologie, Freiburg (Germany); Laniado, M. [Universitaetsklinikum Carl Gustav Carus Dresden, Institut und Poliklinik fuer Radiologische Diagnostik, Dresden (Germany); Lotz, J. [Universitaetsmedizin Goettingen, Institut fuer Diagnostische und Interventionelle Radiologie, Goettingen (Germany); Mentzel, H.J. [Universitaetsklinikum Jena, Institut fuer Diagnostische und Interventionelle Radiologie, Sektion Kinderradiologie, Jena (Germany); Queisser-Wahrendorf, A. [Universitaetsmedizin Mainz, Zentrum fuer Kinder- und Jugendmedizin, Mainz (Germany); Rompel, O. [Universitaetsklinikum Erlangen, Radiologisches Institut, Erlangen (Germany); Schlick, I. [Klinikum Nuernberg Sued, Institut fuer Radiologie und Neuroradiologie, Nuremberg (Germany); Schneider, K.; Seidenbusch, M. [Institut fuer Klinische Radiologie, Klinikum der Universitaet Muenchen, Dr. von Haunersches Kinderspital, Munich (Germany); Schumacher, M. [Universitaetsklinik Freiburg, Klinik fuer Neuroradiologie, Neurozentrum, Freiburg (Germany); Spix, C. [University Medical Center Mainz, German Childhood Cancer Registry, Mainz (Germany); Spors, B. [Charite - Universitaetsmedizin Berlin, Kinderradiologie, Standort Campus Virchow Klinikum, Berlin (Germany); Staatz, G. [Universitaetsmedizin Mainz, Klinik und Poliklinik fuer diagnostische und interventionelle Radiologie, Sektion Kinderradiologie, Mainz (Germany); Vogl, T. [Klinikum der Johann Wolfgang Goethe-Universitaet Frankfurt/Main, Institut fuer Diagnostische und Interventionelle Radiologie, Frankfurt (Germany); Wagner, J. [Vivantes, Klinikum im Friedrichshain, Institut fuer Radiologie und Interventionelle Therapie, Berlin (Germany); Weisser, G. [Universitaetsklinikum Mannheim, Institut fuer Klinische Radiologie und Nuklearmedizin, Mannheim (Germany)

    2015-03-15

    The aim of this cohort study was to assess the risk of developing cancer, specifically leukaemia, tumours of the central nervous system and lymphoma, before the age of 15 years in children previously exposed to computed tomography (CT) in Germany. Data for children with at least one CT between 1980 and 2010 were abstracted from 20 hospitals. Cancer cases occurring between 1980 and 2010 were identified by stochastic linkage with the German Childhood Cancer Registry (GCCR). For all cases and a sample of non-cases, radiology reports were reviewed to assess the underlying medical conditions at time of the CT. Cases were only included if diagnosis occurred at least 2 years after the first CT and no signs of cancer were recorded in the radiology reports. Standardised incidence ratios (SIR) using incidence rates from the general population were estimated. The cohort included information on 71,073 CT examinations in 44,584 children contributing 161,407 person-years at risk with 46 cases initially identified through linkage with the GCCR. Seven cases had to be excluded due to signs possibly suggestive of cancer at the time of first CT. Overall, more cancer cases were observed (O) than expected (E), but this was mainly driven by unexpected and possibly biased results for lymphomas. For leukaemia, the SIR (SIR = O/E) was 1.72 (95 % CI 0.89-3.01, O = 12), and for CNS tumours, the SIR was 1.35 (95 % CI 0.54-2.78, O = 7). Despite careful examination of the medical information, confounding by indication or reverse causation cannot be ruled out completely and may explain parts of the excess. Furthermore, the CT exposure may have been underestimated as only data from the participating clinics were available. This should be taken into account when interpreting risk estimates. (orig.)

  18. Risk of cancer incidence before the age of 15 years after exposure to ionising radiation from computed tomography: results from a German cohort study.

    Science.gov (United States)

    Krille, L; Dreger, S; Schindel, R; Albrecht, T; Asmussen, M; Barkhausen, J; Berthold, J D; Chavan, A; Claussen, C; Forsting, M; Gianicolo, E A L; Jablonka, K; Jahnen, A; Langer, M; Laniado, M; Lotz, J; Mentzel, H J; Queißer-Wahrendorf, A; Rompel, O; Schlick, I; Schneider, K; Schumacher, M; Seidenbusch, M; Spix, C; Spors, B; Staatz, G; Vogl, T; Wagner, J; Weisser, G; Zeeb, H; Blettner, M

    2015-03-01

    The aim of this cohort study was to assess the risk of developing cancer, specifically leukaemia, tumours of the central nervous system and lymphoma, before the age of 15 years in children previously exposed to computed tomography (CT) in Germany. Data for children with at least one CT between 1980 and 2010 were abstracted from 20 hospitals. Cancer cases occurring between 1980 and 2010 were identified by stochastic linkage with the German Childhood Cancer Registry (GCCR). For all cases and a sample of non-cases, radiology reports were reviewed to assess the underlying medical conditions at time of the CT. Cases were only included if diagnosis occurred at least 2 years after the first CT and no signs of cancer were recorded in the radiology reports. Standardised incidence ratios (SIR) using incidence rates from the general population were estimated. The cohort included information on 71,073 CT examinations in 44,584 children contributing 161,407 person-years at risk with 46 cases initially identified through linkage with the GCCR. Seven cases had to be excluded due to signs possibly suggestive of cancer at the time of first CT. Overall, more cancer cases were observed (O) than expected (E), but this was mainly driven by unexpected and possibly biased results for lymphomas. For leukaemia, the SIR (SIR = O/E) was 1.72 (95 % CI 0.89-3.01, O = 12), and for CNS tumours, the SIR was 1.35 (95 % CI 0.54-2.78, O = 7). Despite careful examination of the medical information, confounding by indication or reverse causation cannot be ruled out completely and may explain parts of the excess. Furthermore, the CT exposure may have been underestimated as only data from the participating clinics were available. This should be taken into account when interpreting risk estimates.

  19. Generation of virtual monochromatic CBCT from dual kV/MV beam projections

    International Nuclear Information System (INIS)

    Li, Hao; Liu, Bo; Yin, Fang-Fang

    2013-01-01

    Purpose: To develop a novel on-board imaging technique which allows generation of virtual monochromatic (VM) cone-beam CT (CBCT) with a selected energy from combined kilovoltage (kV)/megavoltage (MV) beam projections. Methods: With the current orthogonal kV/MV imaging hardware equipped in modern linear accelerators, both MV projections (from gantry angle of 0°–100°) and kV projections (90°–200°) were acquired as gantry rotated a total of 110°. A selected range of overlap projections between 90° to 100° were then decomposed into two material projections using experimentally determined parameters from orthogonally stacked aluminum and acrylic step-wedges. Given attenuation coefficients of aluminum and acrylic at a predetermined energy, one set of VM projections could be synthesized from two corresponding sets of decomposed projections. Two linear functions were generated using projection information at overlap angles to convert kV and MV projections at nonoverlap angles to approximate VM projections for CBCT reconstruction. The contrast-to-noise ratios (CNRs) were calculated for different inserts in VM CBCTs of a CatPhan phantom with various selected energies and compared with those in kV and MV CBCTs. The effect of overlap projection number on CNR was evaluated. Additionally, the effect of beam orientation was studied by scanning the CatPhan sandwiched with two 5 cm solid-water phantoms on both lateral sides and an electronic density phantom with two metal bolt inserts. Results: Proper selection of VM energy [30 and 40 keV for low-density polyethylene (LDPE), polymethylpentene, 2 MeV for Delrin] provided comparable or even better CNR results as compared with kV or MV CBCT. An increased number of overlap kV and MV projection demonstrated only marginal improvements of CNR for different inserts (with the exception of LDPE) and therefore one projection overlap was found to be sufficient for the CatPhan study. It was also evident that the optimal CBCT image

  20. THE CALIBRATION OF MONOCHROMATIC FAR-INFRARED STAR FORMATION RATE INDICATORS

    International Nuclear Information System (INIS)

    Calzetti, D.; Wu, S.-Y.; Hong, S.; Kennicutt, R. C.; Hao, C.-N.; Begum, A.; Johnson, B.; Lee, J. C.; Dale, D. A.; Engelbracht, C. W.; Block, M.; Van Zee, L.; Draine, B. T.; Gordon, K. D.; Regan, M.; Moustakas, J.; Murphy, E. J.; Dalcanton, J.; Funes, J.; Gil de Paz, A.

    2010-01-01

    Spitzer data at 24, 70, and 160 μm and ground-based Hα images are analyzed for a sample of 189 nearby star-forming and starburst galaxies to investigate whether reliable star formation rate (SFR) indicators can be defined using the monochromatic infrared dust emission centered at 70 and 160 μm. We compare recently published recipes for SFR measures using combinations of the 24 μm and observed Hα luminosities with those using 24 μm luminosity alone. From these comparisons, we derive a reference SFR indicator for use in our analysis. Linear correlations between SFR and the 70 μm and 160 μm luminosity are found for L(70) ∼> 1.4 x 10 42 erg s -1 and L(160) ∼> 2 x 10 42 erg s -1 , corresponding to SFR ∼> 0.1-0.3 M sun yr -1 , and calibrations of SFRs based on L(70) and L(160) are proposed. Below those two luminosity limits, the relation between SFR and 70 μm (160 μm) luminosity is nonlinear and SFR calibrations become problematic. A more important limitation is the dispersion of the data around the mean trend, which increases for increasing wavelength. The scatter of the 70 μm (160 μm) data around the mean is about 25% (factor ∼2) larger than the scatter of the 24 μm data. We interpret this increasing dispersion as an effect of the increasing contribution to the infrared emission of dust heated by stellar populations not associated with the current star formation. Thus, the 70 (160) μm luminosity can be reliably used to trace SFRs in large galaxy samples, but will be of limited utility for individual objects, with the exception of infrared-dominated galaxies. The nonlinear relation between SFR and the 70 and 160 μm emission at faint galaxy luminosities suggests a variety of mechanisms affecting the infrared emission for decreasing luminosity, such as increasing transparency of the interstellar medium, decreasing effective dust temperature, and decreasing filling factor of star-forming regions across the galaxy. In all cases, the calibrations hold

  1. Receiver-supported radiometry with cryoradiometers and monochromatized synchrotron radiation; Empfaengergestuetzte Radiometrie mit Kryoradiometern und monochromatisierter Synchrotronstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Gottwald, Alexander [Physikalisch-Technische Bundesanstalt (PTB), Berlin (Germany). Arbeitsgruppe ' UV- und VUV-Radiometrie' ; Kroth, Udo; Krumrey, Michael; Mueller, Peter; Scholze, Frank

    2014-09-15

    The cryoradiometers SYRES I and SYRES II used at the PTB are described. They consist of a cavity absorber and are operated at temperatures slightly above the boiling point of liquid helium. The calibration of the spectral sensitivity in the range from 3 eV to 100 keV is described. (HSI)

  2. Effect of an external alternating electric field non-monochromaticity on parametric excitation of surface ion cyclotron X-modes

    International Nuclear Information System (INIS)

    Girka, V O; Puzyrkov, S Yu; Shpagina, V O; Shpagina, L O

    2012-01-01

    The application of an external alternating electric field in the range of ion cyclotron frequencies is a well-known method for the excitation of surface electromagnetic waves. The present paper is devoted to the development of a kinetic theory of parametric excitation of these eigenwaves propagating across an external steady magnetic field along the plasma boundary at the second harmonic of the ion cyclotron frequency. Unlike previous papers on this subject, parametric excitation of surface ion cyclotron X-modes is studied here under the condition of non-monochromaticity of an external alternating electric field. Non-monochromaticity of the external alternating electric field is modeled by the superposition of two uniform and monochromatic electric fields with different amplitudes and frequencies. The nonlinear boundary condition is formulated for a tangential magnetic field of the studied surface waves. An infinite set of equations for the harmonics of a tangential electric field is solved using the approximation of the wave packet consisting of the main harmonic and two nearest satellite harmonics. Two different regimes of instability have been considered. If one of the applied generators has an operation frequency that is close to the ion cyclotron frequency, then changing the amplitude of the second generator allows one to enhance the growth rate of the parametric instability or to diminish it. But if the operation frequencies of the both generators are not close to the ion cyclotron frequency, then changing the amplitudes of their fields allows one to decrease the growth rate of the instability and even to suppress its development. The problem is studied both analytically and numerically.

  3. Observation of Intravascular Changes of Superabsorbent Polymer Microsphere (SAP-MS) with Monochromatic X-Ray Imaging

    International Nuclear Information System (INIS)

    Tanimoto, Daigo; Ito, Katsuyoshi; Yamamoto, Akira; Sone, Teruki; Kobatake, Makito; Tamada, Tsutomu; Umetani, Keiji

    2010-01-01

    This study was designed to evaluate the intravascular transformation behavior of superabsorbent polymer microsphere (SAP-MS) in vivo macroscopically by using monochromatic X-ray imaging and to quantitatively compare the expansion rate of SAP-MS among different kinds of mixtures. Fifteen rabbits were used for our study and transcatheter arterial embolization (TAE) was performed for their auricular arteries using monochromatic X-ray imaging. We used three kinds of SAP-MS (particle diameter 100-150 μm) mixture as embolic spherical particles: SAP-MS(H) absorbed with sodium meglumine ioxaglate (Hexabrix 320), SAP-MS(V) absorbed with isosmolar contrast medium (Visipaque 270), and SAP-MS(S) absorbed with 0.9% sodium saline. The initial volume of SAP-MS particles just after TAE and its final volume 10 minutes after TAE in the vessel were measured to calculate the expansion rate (ER) (n = 30). Intravascular behavior of SAP-MS particles was clearly observed in real time at monochromatic X-ray imaging. Averaged initial volumes of SAP-MS (H) (1.24 x 10 7 μm 3 ) were significantly smaller (p 7 μm 3 ) and SAP-MS (S) (5.85 x 10 7 μm 3 ). Averaged final volumes of SAP-MS (H) were significantly larger than averaged initial volumes (4.41 x 10 7 μm 3 vs. 1.24 x 10 7 μm 3 ; p < 0.0001, ER = 3.55). There were no significant difference between averaged final volumes and averaged initial volumes of SAP-MS (V) and SAP-MS (S). SAP-MS (H), which first travels distally, reaches to small arteries, and then expands to adapt to the vessel lumen, is an effective particle as an embolic agent, causing effective embolization.

  4. Studies and comparisons of two photon-tagging systems for the production of monochromatic photon beams for photonuclear experiments

    International Nuclear Information System (INIS)

    Aniel, Thierry.

    1982-06-01

    The performance of photon beams obtained by two different tagging processes (tagging of ''hard'' annihilation photons with ''soft'' associated photons, tagging of bremstrahlung photons with associated electrons) on the same facility was studied. The two processes are described and experimental results on the characteristics of the resulting beams given. The respective advantages of both methods are compared with one another and with those of a quasi-monochromatic beam obtained by the in-flight annihilation of a positron beam. A development based on the second process is then studied together with its applications to photonuclear physics [fr

  5. Note: Diagnosing femtosecond laser-solid interactions with monochromatic Kα imager and x-ray pinhole camera

    International Nuclear Information System (INIS)

    Lin, X. X.; Li, Y. T.; Liu, F.; Du, F.; Wang, S. J.; Chen, L. M.; Zhang, L.; Zheng, Y.; Liu, X.; Liu, X. L.; Wang, Z. H.; Ma, J. L.; Wei, Z. Y.; Liu, B. C.; Zhang, J.

    2011-01-01

    An x-ray pinhole camera and a monochromatic K α imager are used to measure the interactions of intense femtosecond laser pulses with Cu foil targets. The two diagnostics give different features in the spot size and the laser energy scaling, which are resulted from different physical processes. Under our experimental conditons, the K α emission is mainly excited by the fast electrons transporting inside the cold bulk target. In contrast, the x-ray pinhole signals are dominated by the broadband thermal x-ray emission from the hot plasma at the front target surface.

  6. Recovery from Iridium-192 flakes of a radioactive source for industrial use after a radiation incident; Recuperacion de hojuelas de Iridio-192 provenientes de una fuente radiactivas de uso industrial despues de un incidente radiologico

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, W.H.; Zapata, L.A., E-mail: wcruz@ipen.gob.pe, E-mail: lzapata@ipen.gob.pe [Instituto Peruano de Energia Nuclear (GRRA/IPEN), Lima (Peru). Division de Gestion de Residuos Radiactivos

    2013-07-01

    The Iridium-192 ({sup 192}Ir) is the most used and ideal for industrial radiography applications, especially in petrochemical plants and pipelines and provides better contrast sensitivity for thick (25.4 mm). This source has constructive sealed double encapsulation, the internal capsule containing stainless steel to radioactive material in the form of flakes and welded with TIG process. The radiological incident happened at a gas station fuel sales in circumstances in which there was a homogeneity test welds a tank, the flakes or Ir-192 fell off his ponytail and left scattered over an area of 2 m{sup 2}, some fell flat areas and other land so collected in lead shielding and metal container and ground source. Full recovery of the leaflets was performed at the Division of radioactive waste management (GRRA) gaining a total of 22 flakes with no radiation risk to staff performance and installation and the conclusion was reached that the misapplicaion of TIG welding was the main cause the incident. (author)

  7. Nasopharyngeal carcinoma in a low incidence European area. A prospective observational analysis from the Head and Neck Study Group of the Italian Society of Radiation Oncology (AIRO)

    Energy Technology Data Exchange (ETDEWEB)

    Tonoli, S.; Bruschieri, L. [Brescia University, Istituto del Radio, Brescia (Italy); Alterio, D. [European Institute of Oncology, Milan (Italy); Caspiani, O. [Isola Tiberina Hospital, Rome (Italy); Bacigalupo, A. [IRCCS A.O.U. San Martino IST Genoa, Genoa (Italy); Bunkheila, F. [S. Orsola Hospital, Bologna (Italy); Cianciulli, M. [S. Camillo Hospital, Rome (Italy); Merlotti, A. [Busto Arsizio Hospital, Busto Arsizio (Italy); Podhradska, A. [Milan University - Monza S. Gerardo Hospital, Milan (Italy); Rampino, M. [Turin University, Turin (Italy); Cante, D. [Treviglio Hospital, Treviglio (Italy); Gatta, R. [Brescia University, Istituto del Radio, Brescia (Italy); Prato Hospital, Prato (Italy); Magrini, S.M.

    2016-12-15

    To evaluate the outcomes with respect to long-term survival and toxicity in patients with nasopharyngeal carcinoma (NPC) treated in a European country with low incidence. A prospective observational study carried out by the AIRO Head and Neck group in 12 Italian institutions included 136 consecutive patients treated with radiotherapy (RT) ± chemotherapy (CHT) for NPC (without distant metastasis) between January 1, 2008 and December 31, 2010. The disease-specific survival (DSS), overall survival (OS), and disease-free survival (DFS) at 5 years were 92 (±2), 91 (±3), and 69 % (±5 %), respectively. Distant failure was the most frequent modality of relapse. The local, regional, and locoregional control at 5 years were 89 (±3), 93 (±3), and 84 % (±4 %), respectively. The incidence of acute and late toxicity and the correlations with different clinical/technical variables were analyzed. Neoadjuvant CHT prolongs radiotherapy overall treatment time (OTT) and decreases treatment adherence during concomitant chemoradiotherapy. An adequate minimum dose coverage to PTV(T) is a predictive variable well related to outcome. Our data do not substantially differ in terms of survival and toxicity outcomes from those reported in larger series of patients treated in countries with higher incidences of NPC. The T stage (TNM 2002 UICC classification) is predictive of DSS and OS. The GTV volume (T ± N) and an adequate minimum PTV(T) coverage dose (D95 %) were also identified as potential predictive variables. Sophisticated technologies of dose delivery (IMRT) with image-guided radiotherapy could help to obtain better minimum PTV(T) coverage dose with increased DFS; distant metastasis after treatment still remains an unresolved issue. (orig.) [German] Bewertung von langfristigem Ueberleben und Toxizitaet bei Patienten mit Nasopharynxkarzinom (NPC), die in einem europaeischen Land mit geringer Inzidenz behandelt wurden. Die prospektive Beobachtungsanalyse, durchgefuehrt von der

  8. Leukaemia incidence in Welsh children linked with low level radiation-making sense of some erroneous results published in the media

    International Nuclear Information System (INIS)

    Steward, John A; White, Ceri; Reynolds, Shelagh

    2008-01-01

    A series of self-published epidemiological reports purporting to show a major excess risk of leukaemia in pre-school children living near the Irish Sea coast of Wales have been presented in the media as evidence of the harmful effects of low level radiation arising from Sellafield. The Welsh Cancer Intelligence and Surveillance Unit (WCISU), the body responsible for population-based cancer information in Wales, can provide insights into the validity of these reports, which appear to be a consequence of various mistakes. This raises important questions about the research governance of such reports and the communication of scientific findings via the mass media. Without suitable safeguards the media are in danger of promulgating misinformation

  9. The change in color matches with retinal angle of incidence of the colorimeter beams.

    Science.gov (United States)

    Alpern, M; Kitahara, H; Fielder, G H

    1987-01-01

    Differences between W.D.W. chromaticities of monochromatic lights obtained with all colorimeter beams incident on the retina "off-axis" and those found for lights striking the retina normally have been studied throughout the visible spectrum on 4 normal trichromats. The results are inconsistent with: (i) the assumption in Weale's theories of the Stiles-Crawford hue shift that the sets of absorption spectra of the visual pigments catching normally and obliquely incident photons are identical, and (ii) "self-screening" explanations for the change in color with angle of incidence on the retina. The color matching functions of a protanomalous trichromat are inconsistent with the hypothesis that the absorption spectra of the visual pigments catching normally incident photons in his retina are those catching obliquely incident photons in the normal retina.

  10. Enhancing monochromatic multipole emission by a subwavelength enclosure of degenerate Mie resonances

    KAUST Repository

    Zhao, Jiajun; Zhang, Likun; Wu, Ying

    2017-01-01

    of the enclosure, and meanwhile the radiation directivity pattern is well preserved. The degeneracy is theoretically analyzed. A realization of the material is suggested by using a space-coiling structure.

  11. Interim report of the DOE [Department of Energy] Type B Investigation Group: Appendix C, Oral statements about the RSI [Radiation Sterilizers, Inc.] incident

    International Nuclear Information System (INIS)

    Hultgren, R.O.

    1990-07-01

    Sometime between April 28, 1988, and June 5, 1988, a 22-inch long by 2.625-inch diameter doubly encapsulated cesium-137 irradiation source began leaking in the RSI-Decatur, Georgia, irradiation facility. By November 1988 when the source was isolated, between 7 and 8 curies (0.4 grams) leaked. This source was one of 1576 produced at Hanford to isolate the highly radioactive elements of wastes stored in single-walled tanks there. The capsule was designed for long term storage in a benign controlled pool environment on the Hanford reservation. An investigation was conducted to evaluate the cause of the incident, the management and administrative matters including leasing and licensing, the capsule design and manufacture, and the capsule qualification process. This Appendix presents transcripts of oral testimony taken during this investigation and is include as an integral part of the factual data upon which the Findings of this report are based. The transcriptions in every case were made available to the individuals involved for correction of factual misstatements and to be cleaned of verbal idiosyncrasies that detract from the meaning of the text

  12. Repair kinetics of DNA double-strand breaks and incidence of apoptosis in mouse neural stem/progenitor cells and their differentiated neurons exposed to ionizing radiation.

    Science.gov (United States)

    Kashiwagi, Hiroki; Shiraishi, Kazunori; Sakaguchi, Kenta; Nakahama, Tomoya; Kodama, Seiji

    2018-05-01

    Neuronal loss leads to neurodegenerative disorders, including Alzheimer's disease, Parkinson's disease and Huntington's disease. Because of their long lifespans, neurons are assumed to possess highly efficient DNA repair ability and to be able to protect themselves from deleterious DNA damage such as DNA double-strand breaks (DSBs) produced by intrinsic and extrinsic sources. However, it remains largely unknown whether the DSB repair ability of neurons is more efficient compared with that of other cells. Here, we investigated the repair kinetics of X-ray-induced DSBs in mouse neural cells by scoring the number of phosphorylated 53BP1 foci post irradiation. We found that p53-independent apoptosis was induced time dependently during differentiation from neural stem/progenitor cells (NSPCs) into neurons in culture for 48 h. DSB repair in neurons differentiated from NSPCs in culture was faster than that in mouse embryonic fibroblasts (MEFs), possibly due to the higher DNA-dependent protein kinase activity, but it was similar to that in NSPCs. Further, the incidence of p53-dependent apoptosis induced by X-irradiation in neurons was significantly higher than that in NSPCs. This difference in response of X-ray-induced apoptosis between neurons and NSPCs may reflect a difference in the fidelity of non-homologous end joining or a differential sensitivity to DNA damage other than DSBs.

  13. Low incidence of chest wall pain with a risk-adapted lung stereotactic body radiation therapy approach using three or five fractions based on chest wall dosimetry.

    Directory of Open Access Journals (Sweden)

    Thibaud P Coroller

    Full Text Available PURPOSE: To examine the frequency and potential of dose-volume predictors for chest wall (CW toxicity (pain and/or rib fracture for patients receiving lung stereotactic body radiotherapy (SBRT using treatment planning methods to minimize CW dose and a risk-adapted fractionation scheme. METHODS: We reviewed data from 72 treatment plans, from 69 lung SBRT patients with at least one year of follow-up or CW toxicity, who were treated at our center between 2010 and 2013. Treatment plans were optimized to reduce CW dose and patients received a risk-adapted fractionation of 18 Gy×3 fractions (54 Gy total if the CW V30 was less than 30 mL or 10-12 Gy×5 fractions (50-60 Gy total otherwise. The association between CW toxicity and patient characteristics, treatment parameters and dose metrics, including biologically equivalent dose, were analyzed using logistic regression. RESULTS: With a median follow-up of 20 months, 6 (8.3% patients developed CW pain including three (4.2% grade 1, two (2.8% grade 2 and one (1.4% grade 3. Five (6.9% patients developed rib fractures, one of which was symptomatic. No significant associations between CW toxicity and patient and dosimetric variables were identified on univariate nor multivariate analysis. CONCLUSIONS: Optimization of treatment plans to reduce CW dose and a risk-adapted fractionation strategy of three or five fractions based on the CW V30 resulted in a low incidence of CW toxicity. Under these conditions, none of the patient characteristics or dose metrics we examined appeared to be predictive of CW pain.

  14. Radiation biology using synchrotron radiation. In relation to radiation chemistry as an initial process

    International Nuclear Information System (INIS)

    Kobayashi, Katsumi

    1995-01-01

    Radiation biology using synchrotron radiation have been investigated, focusing on the mechanism of the formation of molecular damage. This paper introduces recent outcome of these studies. First, the process from imparted energy to the formation of molecular damage is outlined. The previous studies can be largely categorized as dealing with (1) biological effects of inner-shell ionization on elements composing the living body and (2) X-ray energy dependence of biological effects. Bromine and phosphorus are used as elements for the study of inner-cell ionization. In the study on lethal effects of monochromatic soft X-rays on the BrdUMP-incorporated yeast cells, Auger enhancement was found to occur. The first report on the effects of K-shell absorption of cellular phosphorus atoms has revealed that biological effects on cellular lethality and genetic changes was enhanced by 40%. Plasmid DNA and oligonucleotide have been used to study biological effects of vacuum ultraviolet rays to monochromatic soft X-ray, which makes it possible to study strand breaks. Because experimental production of energy required for the formation of double strand breaks has become possible, synchrotron radiation plays a very important role in radiation biological studies. Finally, future issues are presented. (N.K.)

  15. Analysis of gas exchange, stomatal behaviour and micronutrients uncovers dynamic response and adaptation of tomato plants to monochromatic light treatments.

    Science.gov (United States)

    O'Carrigan, Andrew; Babla, Mohammad; Wang, Feifei; Liu, Xiaohui; Mak, Michelle; Thomas, Richard; Bellotti, Bill; Chen, Zhong-Hua

    2014-09-01

    Light spectrum affects the yield and quality of greenhouse tomato, especially over a prolonged period of monochromatic light treatments. Physiological and chemical analysis was employed to investigate the influence of light spectral (blue, green and red) changes on growth, photosynthesis, stomatal behaviour, leaf pigment, and micronutrient levels. We found that plants are less affected under blue light treatment, which was evident by the maintenance of higher A, gs, Tr, and stomatal parameters and significantly lower VPD and Tleaf as compared to those plants grown in green and red light treatments. Green and red light treatments led to significantly larger increase in the accumulation of Fe, B, Zn, and Cu than blue light. Moreover, guard cell length, width, and volume all showed highly significant positive correlations to gs, Tr and negative links to VPD. There was negative impact of monochromatic lights-induced accumulation of Mn, Cu, and Zn on photosynthesis, leaf pigments and plant growth. Furthermore, most of the light-induced significant changes of the physiological traits were partially recovered at the end of experiment. A high degree of morphological and physiological plasticity to blue, green and red light treatments suggested that tomato plants may have developed mechanisms to adapt to the light treatments. Thus, understanding the optimization of light spectrum for photosynthesis and growth is one of the key components for greenhouse tomato production. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  16. Dual Energy CT (DECT) Monochromatic Imaging: Added Value of Adaptive Statistical Iterative Reconstructions (ASIR) in Portal Venography.

    Science.gov (United States)

    Zhao, Liqin; Winklhofer, Sebastian; Jiang, Rong; Wang, Xinlian; He, Wen

    2016-01-01

    To investigate the effect of the adaptive statistical iterative reconstructions (ASIR) on image quality in portal venography by dual energy CT (DECT) imaging. DECT scans of 45 cirrhotic patients obtained in the portal venous phase were analyzed. Monochromatic images at 70keV were reconstructed with the following 4 ASIR percentages: 0%, 30%, 50%, and 70%. The image noise (IN) (standard deviation, SD) of portal vein (PV), the contrast-to-noise-ratio (CNR), and the subjective score for the sharpness of PV boundaries, and the diagnostic acceptability (DA) were obtained. The IN, CNR, and the subjective scores were compared among the four ASIR groups. The IN (in HU) of PV (10.05±3.14, 9.23±3.05, 8.44±2.95 and 7.83±2.90) decreased and CNR values of PV (8.04±3.32, 8.95±3.63, 9.80±4.12 and 10.74±4.73) increased with the increase in ASIR percentage (0%, 30%, 50%, and 70%, respectively), and were statistically different for the 4 ASIR groups (pASIR percentages (pASIR (pASIR addition in DECT portal venography could improve the 70 keV monochromatic image quality.

  17. Contact microscopy with synchrotron radiation

    International Nuclear Information System (INIS)

    Panessa-Warren, B.J.

    1985-10-01

    Soft x-ray contact microscopy with synchrotron radiation offers the biologist and especially the microscopist, a way to morphologically study specimens that could not be imaged by conventional TEM, STEM or SEM methods (i.e. hydrated samples, samples easily damaged by an electron beam, electron dense samples, thick specimens, unstained low contrast specimens) at spatial resolutions approaching those of the TEM, with the additional possibility to obtain compositional (elemental) information about the sample as well. Although flash x-ray sources offer faster exposure times, synchrotron radiation provides a highly collimated, intense radiation that can be tuned to select specific discrete ranges of x-ray wavelengths or specific individual wavelengths which optimize imaging or microanalysis of a specific sample. This paper presents an overview of the applications of x-ray contact microscopy to biological research and some current research results using monochromatic synchrotron radiation to image biological samples. 24 refs., 10 figs

  18. Medical applications of synchrotron radiation

    International Nuclear Information System (INIS)

    Thomlinson, W.

    1992-01-01

    Ever since the first diagnostic X-ray was done in the United States on February 3, 1896, the application of ionizing radiation to the field of medicine has become incrasingly important. Both in clinical medicine and basic research the use of X-rays for diagnostic imaging and radiotherapy is now widespread. Radiography, angiography, CAT and PETT scanning, mammography, and nuclear medicine are all examples of technologies developed to image the human anatomy. In therapeutic applications, both external and internal sources of radiation are applied to the battle against cancer. The development of dedicated synchrotron radiation sources has allowed exciting advances to take place in many of these applications. The new sources provide tunable, high-intensity monochromatic beams over a wide range of energies which can be tailored to specific programmatic needs. This paper surveys those areas of medical research in which synchrotron radiation facilities are actively involved. (orig.)

  19. Medical applications of synchrotron radiation

    International Nuclear Information System (INIS)

    Thomlinson, W.

    1991-10-01

    Ever since the first diagnostic x-ray was done in the United States on February 3, 1896, the application of ionizing radiation to the field of medicine has become increasingly important. Both in clinical medicine and basic research the use of x-rays for diagnostic imaging and radiotherapy is now widespread. Radiography, angiography, CAT and PETT scanning, mammography, and nuclear medicine are all examples of technologies developed to image the human anatomy. In therapeutic applications, both external and internal sources of radiation are applied to the battle against cancer. The development of dedicated synchrotron radiation sources has allowed exciting advances to take place in many of these applications. The new sources provide tunable, high-intensity monochromatic beams over a wide range of energies which can be tailored to specific programmatic needs. This paper surveys those areas of medical research in which synchrotron radiation facilities are actively involved

  20. Studies for the development of a micro-focus monochromatic x-ray source with making use of a highly charged heavy ion beam

    International Nuclear Information System (INIS)

    Nakamura, Nobuyuki; Yoshiyasu, Nobuo; Nakayama, Ryo; Watanabe, Hirofumi

    2008-01-01

    We propose a new scheme for a micro-focus monochromatic X-ray source using a focused highly charged ion beam colliding with a solid surface. When highly charged ion approaches a surface, many electrons are captured into the ion and the so-called hollow atom is produced. The hollow atom will decay by emitting X-rays before and after hitting the surface. Such X-rays do not contain any contribution from bremsstrahlung, so that monochromatic X-rays can be obtained by using proper filters. For the first step of realizing the proposed scheme, an ion focusing system with a glass capillary has been developed. In order to study the monochromaticity of the emission, X-ray spectra from hollow atoms produced in the collisions between highly charged heavy ions and several surfaces have been observed. (author)

  1. Radiation carcinogenesis

    International Nuclear Information System (INIS)

    Fry, R.J.M.

    1976-01-01

    The risk of iatrogenic tumors with radiation therapy is so outweighed by the benefit of cure that estimates of risk have not been considered necessary. However, with the introduction of chemotherapy, combined therapy, and particle radiation therapy, the comparative risks should be examined. In the case of radiation, total dose, fractionation, dose rate, dose distribution, and radiation quality should be considered in the estimation of risk. The biological factors that must be considered include incidence of tumors, latent period, degree of malignancy, and multiplicity of tumors. The risk of radiation induction of tumors is influenced by the genotype, sex, and age of the patient, the tissues that will be exposed, and previous therapy. With chemotherapy the number of cells at risk is usually markedly higher than with radiation therapy. Clearly the problem of the estimation of comparative risks is complex. This paper presents the current views on the comparative risks and the importance of the various factors that influence the estimation of risk

  2. Development of an EDV-supported decision instrument for site pre-selection of nuclear power plants. EDV-supported instrument for calculation of the space distribution of the collective dose rate and area contamination. Vol. 1. Radiation exposure through air- and water paths under authorized operating conditions and during incidents

    Energy Technology Data Exchange (ETDEWEB)

    Bruessermann, K; Eschhaus, M; Kreymborg, A; Muenster, M; Schommer, N

    1980-01-01

    The collective dose rate and the area contamination form a basis for site criteria going beyond the individual considerations of distribution of the population, hydrology, meteorology etc. The possibilities of radio-ecological models on the radiation exposure through air- and water paths during operation and incidents are described by example of Biblis, Muelheim-Kaerlich and Esensham. Comparative evaluations were effected for Fessenheim.

  3. Enhanced possibilities of section topography at a third-generation synchrotron radiation facility

    International Nuclear Information System (INIS)

    Medrano, C.; Rejmankova, P.; Ohler, M.; Matsouli, I.

    1997-01-01

    The authors show the new possibilities of section topography techniques at a third-generation synchrotron radiation facility, taking advantage of the high performances of this machine. Examples of the 1) so-called multiple sections, 2) visibility of weakly misoriented regions, 3) study of thick samples, 4) monochromatic and 5) realtime sections are presented

  4. Concept of quasi-periodic undulator - control of radiation spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Shigemi [Japan Atomic Energy Research Institute, Ibaraki (Japan)

    1995-02-01

    A new type of undulator, the quasi-periodic undulator (QPU) is considered which generates the irrational harmonics in the radiation spectrum. This undulator consists of the arrays of magnet blocks aligned in a quasi-periodic order, and consequentially lead to a quasi-periodic motion of electron. A combination of the QPU and a conventional crystal/grating monochromator provides pure monochromatic photon beam for synchrotron radiation users because the irrational harmonics do not be diffracted in the same direction by a monochromator. The radiation power and width of each radiation peak emitted from this undulator are expected to be comparable with those of the conventional periodic undulator.

  5. [Skin cancer incidence in Zacatecas].

    Science.gov (United States)

    Pinedo-Vega, José Luis; Castañeda-López, Rosalba; Dávila-Rangel, J Ignacio; Mireles-García, Fernando; Ríos-Martínez, Carlos; López-Saucedo, Adrián

    2014-01-01

    Skin cancer is the most frequent cancer related to ultraviolet radiation. The aim was to estimate the incidence of skin cancer type, melanoma and non-melanoma in Zacatecas, Mexico. An epidemiological study was carried out during the period from 2008 to 2012. The data were obtained from the Instituto Mexicano del Seguro Social (IMSS), Instituto de Seguridad y Servicios Sociales de los Trabajadores del Estado (ISSSTE), Secretaría de Salud de Zacatecas (SSZ) and a private source, the Centro Médico Alameda. The incidence and the global prevalence were estimated. We studied 958 skin cancer cases, histopathologically confirmed. The cases were distributed as: 63.6 % basal cell carcinomas, 25.8 % squamous cell carcinomas, and 10.6 % melanoma. Significantly higher proportions were observed in women in the basal cell carcinomas (60.4 %) and squamous cell carcinomas (53.4 %). However, in the case of melanoma, the major proportion was observed in men (55.9 %). The more frequent skin cancer location was the face and for basal cell carcinoma was the nose (53 %); for squamous cell carcinomas were the lips (36 %), and for melanoma it was also the nose (40 %). The skin cancer incidence was estimated in 20 cases for each 100 000 inhabitants. Linear regression analysis showed that the skin cancer is increasing at an annual rate of 10.5 %. The anatomical location indicates that solar UV radiation is a risk factor, since the face is the zone with major exposure to solar radiation.

  6. Electrostatic quasi-monochromatic waves in the downstream region of the Earth's bow shock based on Geotail observations

    Science.gov (United States)

    Shin, K.; Kojima, H.; Matsumoto, H.; Mukai, T.

    2007-02-01

    Geotail plasma wave observations show the existence of intense electrostatic quasi-monochromatic (EQM) waves in the downstream region of the Earth's bow shock. They oscillate parallel to the ambient magnetic field and appear at frequencies between the electron plasma and ion plasma frequencies. Although these waves have been believed to be Doppler-shifted ion acoustic waves, the typical plasma parameters observed in the downstream region do not support the generation conditions for ion acoustic waves. In this paper, the existence of cold electron beam-like components accompanying EQM waves is considered based on waveform and statistical analyses. Linear dispersion analyses using realistic plasma parameters revealed that the cold electron beams cause destabilization of electron acoustic waves at frequencies consistent with those of observed EQM waves. The results of observations and linear analyses suggest that EQM waves are generated by the destabilization of the electron acoustic mode.

  7. Nonlinear excitation of electron cyclotron waves by a monochromatic strong microwave: computer simulation analysis of the MINIX results

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, H.; Kimura, T.

    1986-01-01

    Triggered by the experimental results of the MINIX, a computer simulation study was initiated on the nonlinear excitation of electrostatic electron cyclotron waves by a monochromatic electromagnetic wave such as the transmitted microwave in the MINIX. The model used assumes that both of the excited waves and exciting (pumping) electromagnetic wave as well as the idler electromagnetic wave propagate in the direction perpendicular to the external magnetic field. The simulation code used for this study was the one-and-two-half dimensional electromagnetic particle code named KEMPO. The simulation result shows the high power electromagnetic wave produces both the backscattered electromagnetic wave and electrostatic electron cyclotron waves as a result of nonlinear parametric instability. Detailed nonlinear microphysics related to the wave excitation is discussed in terms of the nonlinear wave-wave couplings and associated ponderomotive force produced by the high power electromagnetic waves. 2 references, 4 figures.

  8. Nonlinear excitation of electron cyclotron waves by a monochromatic strong microwave: computer simulation analysis of the MINIX results

    International Nuclear Information System (INIS)

    Matsumoto, H.; Kimura, T.

    1986-01-01

    Triggered by the experimental results of the MINIX, a computer simulation study was initiated on the nonlinear excitation of electrostatic electron cyclotron waves by a monochromatic electromagnetic wave such as the transmitted microwave in the MINIX. The model used assumes that both of the excited waves and exciting (pumping) electromagnetic wave as well as the idler electromagnetic wave propagate in the direction perpendicular to the external magnetic field. The simulation code used for this study was the one-and-two-half dimensional electromagnetic particle code named KEMPO. The simulation result shows the high power electromagnetic wave produces both the backscattered electromagnetic wave and electrostatic electron cyclotron waves as a result of nonlinear parametric instability. Detailed nonlinear microphysics related to the wave excitation is discussed in terms of the nonlinear wave-wave couplings and associated ponderomotive force produced by the high power electromagnetic waves. 2 references, 4 figures

  9. Effects of monochromatic light sources on sex hormone levels in serum and on semen quality of ganders.

    Science.gov (United States)

    Chang, Shen-Chang; Zhuang, Zi-Xuan; Lin, Min-Jung; Cheng, Chuen-Yu; Lin, Tsung-Yi; Jea, Yu-Shine; Huang, San-Yuan

    2016-04-01

    Light is an essential external factor influencing various physiological processes, including reproductive performance, in birds. Although several attempts have been made to understand the effect of light on poultry production, the effect of light of a particular wavelength (color) on the reproductive function in geese remains unclear. This study evaluated the effect of various monochromatic light sources on the levels of sex hormone and on semen quality of ganders. Of 30 male White Roman geese in their third reproductive season (average age=3 years), 27 were divided into three groups receiving monochromatic white or red or blue lights. The birds were kept in an environmentally controlled house with a lighting photoperiod of 7L:17D for six weeks as the adaptation period. The photoperiod was subsequently changed to 9L:15D and maintained for 24 weeks. Three ganders at the beginning of the study and three from each group at the end of the adjusting period and the 20th and 30th week of the study period were sacrificed, and their testes and blood samples were collected for determining the sex hormone levels. Semen samples were collected for determining semen quality parameters, including the semen collection index, sperm concentration, semen volume, sperm motility, sperm viability, sperm morphology, and semen quality factor. The results showed that the testosterone and estradiol levels remained unchanged in all three groups at all time points. The ratio of testosterone to estradiol of ganders exposed to white light was significantly higher than that of ganders exposed to red light at the 30th week (PSemen collection index and sperm viability of ganders exposed to blue light were significantly the lowest (Psemen quality than that with red or blue lights in ganders. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Systematic error in the precision measurement of the mean wavelength of a nearly monochromatic neutron beam due to geometric errors

    Energy Technology Data Exchange (ETDEWEB)

    Coakley, K.J., E-mail: kevin.coakley@nist.go [National Institute of Standards and Technology, 325 Broadway, Boulder, CO 80305 (United States); Dewey, M.S. [National Institute of Standards and Technology, Gaithersburg, MD (United States); Yue, A.T. [University of Tennessee, Knoxville, TN (United States); Laptev, A.B. [Tulane University, New Orleans, LA (United States)

    2009-12-11

    Many experiments at neutron scattering facilities require nearly monochromatic neutron beams. In such experiments, one must accurately measure the mean wavelength of the beam. We seek to reduce the systematic uncertainty of this measurement to approximately 0.1%. This work is motivated mainly by an effort to improve the measurement of the neutron lifetime determined from data collected in a 2003 in-beam experiment performed at NIST. More specifically, we seek to reduce systematic uncertainty by calibrating the neutron detector used in this lifetime experiment. This calibration requires simultaneous measurement of the responses of both the neutron detector used in the lifetime experiment and an absolute black neutron detector to a highly collimated nearly monochromatic beam of cold neutrons, as well as a separate measurement of the mean wavelength of the neutron beam. The calibration uncertainty will depend on the uncertainty of the measured efficiency of the black neutron detector and the uncertainty of the measured mean wavelength. The mean wavelength of the beam is measured by Bragg diffracting the beam from a nearly perfect silicon analyzer crystal. Given the rocking curve data and knowledge of the directions of the rocking axis and the normal to the scattering planes in the silicon crystal, one determines the mean wavelength of the beam. In practice, the direction of the rocking axis and the normal to the silicon scattering planes are not known exactly. Based on Monte Carlo simulation studies, we quantify systematic uncertainties in the mean wavelength measurement due to these geometric errors. Both theoretical and empirical results are presented and compared.

  11. Dual Energy CT (DECT Monochromatic Imaging: Added Value of Adaptive Statistical Iterative Reconstructions (ASIR in Portal Venography.

    Directory of Open Access Journals (Sweden)

    Liqin Zhao

    Full Text Available To investigate the effect of the adaptive statistical iterative reconstructions (ASIR on image quality in portal venography by dual energy CT (DECT imaging.DECT scans of 45 cirrhotic patients obtained in the portal venous phase were analyzed. Monochromatic images at 70keV were reconstructed with the following 4 ASIR percentages: 0%, 30%, 50%, and 70%. The image noise (IN (standard deviation, SD of portal vein (PV, the contrast-to-noise-ratio (CNR, and the subjective score for the sharpness of PV boundaries, and the diagnostic acceptability (DA were obtained. The IN, CNR, and the subjective scores were compared among the four ASIR groups.The IN (in HU of PV (10.05±3.14, 9.23±3.05, 8.44±2.95 and 7.83±2.90 decreased and CNR values of PV (8.04±3.32, 8.95±3.63, 9.80±4.12 and 10.74±4.73 increased with the increase in ASIR percentage (0%, 30%, 50%, and 70%, respectively, and were statistically different for the 4 ASIR groups (p<0.05. The subjective scores showed that the sharpness of portal vein boundaries (3.13±0.59, 2.82±0.44, 2.73±0.54 and 2.07±0.54 decreased with higher ASIR percentages (p<0.05. The subjective diagnostic acceptability was highest at 30% ASIR (p<0.05.30% ASIR addition in DECT portal venography could improve the 70 keV monochromatic image quality.

  12. Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses

    NARCIS (Netherlands)

    Wellenberg, R. H. H.; Boomsma, M. F.; van Osch, J. A. C.; Vlassenbroek, A.; Milles, J.; Edens, M. A.; Streekstra, G. J.; Slump, C. H.; Maas, M.

    2017-01-01

    To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer

  13. Preparation of a rhodium catalyst from rhodium trichloride on a flat, conducting alumina support studied with static secondary ion mass spectrometry and monochromatic x-ray photoelectron spectroscopy

    NARCIS (Netherlands)

    Borg, H.J.; Oetelaar, van den L.C.A.; Niemantsverdriet, J.W.

    1993-01-01

    A Rh catalyst was prepd. by electrostatic adsorption of RhCl3-derived species in aq. soln. on a model support, consisting of a 4-5 mm thick layer of Al oxide on an Al foil. The conversion of the Rh precursor species into metallic Rh was studied by monochromatic XPS and static SIMS. Freshly prepd.

  14. Sensitivity and specificity of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen and optic disc oedema: optic disc drusen and oedema.

    Science.gov (United States)

    Gili, Pablo; Flores-Rodríguez, Patricia; Yangüela, Julio; Orduña-Azcona, Javier; Martín-Ríos, María Dolores

    2013-03-01

    Evaluation of the efficacy of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen (ONHD) and optic disc oedema (ODE). Sixty-six patients with ONHD, 31 patients with ODE and 70 healthy subjects were studied. Colour and monochromatic fundus photography with different filters (green, red and autofluorescence) were performed. The results were analysed blindly by two observers. The sensitivity, specificity and interobserver agreement (k) of each test were assessed. Colour photography offers 65.5 % sensitivity and 100 % specificity for the diagnosis of ONHD. Monochromatic photography improves sensitivity and specificity and provides similar results: green filter (71.20 % sensitivity, 96.70 % specificity), red filter (80.30 % sensitivity, 96.80 % specificity), and autofluorescence technique (87.8 % sensitivity, 100 % specificity). The interobserver agreement was good with all techniques used: autofluorescence (k = 0.957), green filter (k = 0.897), red filter (k = 0.818) and colour (k = 0.809). Monochromatic fundus photography permits ONHD and ODE to be differentiated, with good sensitivity and very high specificity. The best results were obtained with autofluorescence and red filter study.

  15. Scheme for Generation highly monochromatic X-Rays from a baseline XFEL undulator

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2010-03-01

    One goal of XFEL facilities is the production of narrow bandwidth X-ray radiation. The self-seeding scheme was proposed to obtain a bandwidth narrower than that achievable with conventional X-ray SASE FELs. A self-seeded FEL is composed of two undulators separated by a monochromator and an electron beam bypass that must compensate for the path delay of X-rays in the monochromator. This leads to a long bypass, with a length in the order of 40-60 m, which requires modifications of the baseline undulator configuration. As an attempt to get around this obstacle, together with a study of the self-seeding scheme for the European XFEL, here we propose a novel technique based on a pulse doubler concept. Using a crystal monochromator installed within a short magnetic chicane in the baseline undulator, it is possible to decrease the bandwidth of the radiation well beyond the XFEL design down to 10 -5 . The magnetic chicane can be installed without any perturbation of the XFEL focusing structure, and does not interfere with the baseline mode of operation. We present a feasibility study and we make exemplifications with the parameters of the SASE2 line of the European XFEL. (orig.)

  16. Biological implications of radiation

    International Nuclear Information System (INIS)

    Bond, V.P.

    1977-01-01

    Some topics discussed are as follows: effects of diagnostic and therapeutic radiation on dividing cells, DNA, and blood cells; radiation sickness in relation to dose; early and late effects of radiation; effects of low dose irradiation; dose-effect curves; radioinduction of tumors in animals; and incidence of cancer in children following in utero exposure to diagnostic x rays

  17. Theoretical study of the thermal radiation of rough surfaces. Development of a device for the measurement of emissivity, and application to AISI 316 stainless steel

    International Nuclear Information System (INIS)

    Heinisch, Bruno

    1982-01-01

    Within the frame of the study of heat transfers by radiation, this research thesis addresses the theoretical and experimental determination of the directional monochromatic emissivity. After some theoretical recalls, the author presents models for a direct calculation of emissivity, which in fact calculate bidirectional reflectivity by using laws of physical optics. An experimental device has been developed for the direct measurement of directional monochromatic emissivity of materials in the infrared (wavelength from 2 to 15 microns) in a polarised radiation. This device uses double beam with double modulation. Experimental results are presented for the 316 stainless steel [fr

  18. Sample Environment in Experiments using X-Ray Synchrotron Radiation

    DEFF Research Database (Denmark)

    Buras, B

    1984-01-01

    beam experiments with wavelength chosen at will from the continuous spectrum. Another type of insertion device, called undulator produces quasi-monochromatic radiation. The insertion devices enable the tailoring of the emitted S.R. to the requirements of the users and can be treated as the first......Modern electron (positron) storage rings are able to emit very intense X-ray radiation with a continuous spectrum extending to 0.1 A, from bending magnets and insertion devices (wavelength shifters and multipole wigglers). It can be used directly for white beam experiments and/or for monochromatic...... optical element of the beam line. This feature is especially important for experiments with samples in special environment because the latter imposes limitations both on scattering and absorption experiments. However, these limitations can be minimized in each case by finding the best match between...

  19. Medical applications with synchrotron radiation in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, T.; Itai, Y. [Univ. of Tsukuba, Inst. of Clinical Medicine, Tsukuba (Japan); Hyodo, K.; Ando, M. [KEK, Tsukuba (Japan); Akatsuka, T. [Yamagata Univ., Faculty of Engineering, Yamagata (Japan); Uyama, C. [National Cardiovascular Centre, Suita (Japan)

    1998-05-01

    In Japan, various medical applications of synchrotron X-ray imaging, such as angiography, monochromatic X-ray computed tomography (CT), radiography and radiation therapy, are being developed. In particular, coronary arteriography (CAG) is quite an important clinical application of synchrotron radiation. Using a two-dimensional imaging method, the first human intravenous CAG was carried out at KEK in May 1996; however, further improvements of image quality are required in clinical practice. On the other hand, two-dimensional aortographic CAG revealed canine coronary arteries as clearly as those on selective CAG, and coronary arteries less than 0.2 mm in diameter. Among applications of synchrotron radiation to X-ray CT, phase-contrast X-ray CT and fluorescent X-ray CT are expected to be very interesting future applications of synchrotron radiation. For actual clinical applications of synchrotron radiation, a medical beamline and a laboratory are now being constructed at SPring-8 in Harima. 55 refs.

  20. Calibration of photographic dosemeters to evaluate the personal equivalent dose, Hp (10), irradiated by different radiation qualities and angles of incidence; Calibracao de dosimetros fotograficos para avaliar o equivalente de dose pessoal, Hp(10), irradiados por diferentes qualidades de radiacao e angulos de incidencia

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, Christiana; Antonio Filho, Joao, E-mail: chsantoro@gmail.com, E-mail: jaf@ufpe.br [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Santos, Marcus Aurelio P.; Goncalves Filho, Luiz Carlos, E-mail: masantos@cnen.gov.br, E-mail: l.filho@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, Pe (Brazil)

    2013-07-01

    To use radiation detectors, should periodically perform tests and calibrations on instruments in order to verify its good functionality. One way to ascertain the quality of the instrument is to conduct a study of the angular dependence of the response of the radiation detectors. The photographic dosimetry has been used widely to quantify the radiation doses and to estimate levels of doses received by workers involved with X-and gamma radiation. Photographic dosimeters are used because provide wide range of exposure and good accuracy. One of the sources of error have been introduced by different irradiation geometries between calibration and measurement in radiation fields used in x-ray and gamma ray sources, therefore, there is a need for an evaluation of the sensitivity of dosimeters with variation of the angle of the incident beam. In this study were tested 190 photographic dosemeters in the Metrology Laboratory of the Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE) using the phantom H{sub p} (10), where the dosimeters are evaluated on the basis of the new operational magnitude for individual monitoring, the equivalent personal dose, H{sub p} (10). Angular dependence of these radiation detectors was studied in X radiation fields (in the range of 45 keV energy to 164 keV) and gamma radiation ({sup 137}Cs-662 keV e {sup 60}Co - 1250 keV)

  1. Goiania incident case study

    International Nuclear Information System (INIS)

    Petterson, J.S.

    1988-06-01

    The reasons for wanting to document this case study and present the findings are simple. According to USDOE technical risk assessments (and our own initial work on the Hanford socioeconomic study), the likelihood of a major accident involving exposure to radioactive materials in the process of site characterization, construction, operation, and closure of a high-level waste repository is extremely remote. Most would agree, however, that there is a relatively high probability that a minor accident involving radiological contamination will occur sometime during the lifetime of the repository -- for example, during transport, at an MRS site or at the permanent site itself during repacking and deposition. Thus, one of the major concerns of the Yucca Mountain Socioeconomic Study is the potential impact of a relatively minor radiation-related accident. A large number of potential impact of a relatively minor radiation-related accident. A large number of potential accident scenarios have been under consideration (such as a transportation or other surface accident which results in a significant decline in tourism, the number of conventions, or the selection of Nevada as a retirement residence). The results of the work in Goiania make it clear, however, that such a significant shift in established social patterns and trends is not likely to occur as a direct outcome of a single nuclear-related accident (even, perhaps, a relatively major one), but rather, are likely to occur as a result of the enduring social interpretations of such an accident -- that is, as a result of the process of understanding, communicating, and socially sustaining a particular set of associations with respect to the initial incident

  2. WE-FG-207B-10: Dual-Energy CT Monochromatic Image Consistency Across Vendors and Platforms

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, M; Wood, C; Cody, D [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: Although dual-energy CT provides improved sensitivity of HU for certain tissue types at lower simulated energy levels, if these values vary by scanner type they may impact clinical patient management decisions. Each manufacturer has selected a specific dual-energy CT approach (or in one case, three different approaches); understanding HU variability among low monochromatic images may be required when more than one dual-energy CT scanner type is available for use. Methods: A large elliptical dualenergy quality control phantom (Gammex Inc.; Middleton, WI) containing several standard tissue type materials was scanned at least three times on each of the following systems: GE HD750, prototype GE Revolution CT with GSI, Siemens Flash, Siemens Edge, Siemens AS 128, and Philips IQon. Images were generated at 50, 70, and 140 keV. Soft tissue and Iodine HU were measured on a single central 5mm-thick image; NIST constants were used to calculate the ideal HU for each material. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were held as consistent as possible (thickness, kernel, no noise reduction). Results: Measured soft tissue (29 HU at 120 kVp) varied from 28 HU to 44 HU at 50 keV (excluding one outlier), from 21 HU to 31 HU at 70 keV, and from 19 HU to 32 HU at 140 keV. Measured iodine (5mg/ml, 106 HU at 120 kVp) varied from 246 HU to 280 HU at 50 keV, from 123 HU to 129 HU at 70 keV, and from 22 HU to 32 HU at 140 keV. Conclusion: Measured HU in standard rods across 3 dual-energy CT manufacturers and 6 scanner models varied directly with monochromatic level, with the most variability was observed at 50 keV and least variability at 70keV. Future work will include additional scanner platforms and how measurement variability impacts radiologists. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

  3. Investigation of fingerprints for small polar molecules by using a tunable monochromatic THz source

    Science.gov (United States)

    Sun, Hongqian

    Over the past 20 years, considerable efforts have been dedicated to the generation and the application of electromagnetic waves in the Terahertz (THz) regime. Among all of the proposed applications, the THz spectroscopy is probably the most mature and promising one. According to the previous reports, the THz spectroscopy has been extensively applied into many analysis fields, including the investigation of vibrational modes for the crystalline solids, the characterization of electron transport in the condense matters and the identification of explosive materials at a standoff distance. More interestingly, since most gas phase chemicals exhibit unique transition peaks in the THz spectra, one could in principle achieve highly accurate molecular fingerprinting and chemical sensing as well. However, all of the practical THz spectroscopy applications were still greatly hampered by the lack of suitable sources and detectors. In this thesis, a unique approach to measure the THz spectrum is developed based on a novel tunable narrowband source. Unlike the previous THz systems, high power THz pulses were generated by the difference frequency generation processes between two collinearly propagated near infrared laser beams. To tune the output THz signal frequency, one can simply adjust one of the incident beam frequencies. Therefore, based on a convenient wavelength tuning scheme, the transmission spectra can be measured for a series of polar gases with either similar or distinct molecular structures. According to the measured spectra, it is found that the obtained transition frequencies, absorption intensities and molecular constants are all in good agreement with the theoretical results tabulated in the molecular spectroscopic databases, such as the HITRAN database. By further analyzing the transition frequencies, it is also discovered that one can confidently identify each polar molecule and differentiate between various isotopic variants based on their characteristic

  4. Brain tumors and synchrotron radiation: Methodological developments in quantitative brain perfusion imaging and radiation therapy

    International Nuclear Information System (INIS)

    Adam, Jean-Francois

    2005-01-01

    High-grade gliomas are the most frequent type of primary brain tumors in adults. Unfortunately, the management of glioblastomas is still mainly palliative and remains a difficult challenge, despite advances in brain tumor molecular biology and in some emerging therapies. Synchrotron radiation opens fields for medical imaging and radiation therapy by using monochromatic intense x-ray beams. It is now well known that angiogenesis plays a critical role in the tumor growth process and that brain perfusion is representative of the tumor mitotic activity. Synchrotron radiation quantitative computed tomography (SRCT) is one of the most accurate techniques for measuring in vivo contrast agent concentration and thus computing precise and accurate absolute values of the brain perfusion key parameters. The methodological developments of SRCT absolute brain perfusion measurements as well as their preclinical validation are detailed in this thesis. In particular, absolute cerebral volume and blood brain barrier permeability high-resolution (pixel size 2 ) parametric maps were reported. In conventional radiotherapy, the treatment of these tumors remains a delicate challenge, because the damages to the surrounding normal brain tissue limit the amount of radiation that can be delivered. One strategy to overcome this limitation is to infuse an iodinated contrast agent to the patient during the irradiation. The contrast agent accumulates in the tumor, through the broken blood brain barrier, and the irradiation is performed with kilovoltage x rays, in tomography mode, the tumor being located at the center of rotation and the beam size adjusted to the tumor dimensions. The dose enhancement results from the photoelectric effect on the heavy element and from the irradiation geometry. Synchrotron beams, providing high intensity, tunable monochromatic x rays, are ideal for this treatment. The beam properties allow the selection of monochromatic irradiation, at the optimal energy, for a

  5. Wavelength dispersive X-ray absorption fine structure imaging by parametric X-ray radiation

    International Nuclear Information System (INIS)

    Inagaki, Manabu; Sakai, Takeshi; Sato, Isamu; Hayakawa, Yasushi; Nogami, Kyoko; Tanaka, Toshinari; Hayakawa, Ken; Nakao, Keisuke

    2008-01-01

    The parametric X-ray radiation (PXR) generator system at Laboratory for Electron Beam Research and Application (LEBRA) in Nihon University is a monochromatic and coherent X-ray source with horizontal wavelength dispersion. The energy definition of the X-rays, which depends on the horizontal size of the incident electron beam on the generator target crystal, has been investigated experimentally by measuring the X-ray absorption near edge structure (XANES) spectra on Cu and CuO associated with conventional X-ray absorption imaging technique. The result demonstrated the controllability of the spectrum resolution of XANES by adjusting of the horizontal electron beam size on the target crystal. The XANES spectra were obtained with energy resolution of several eV at the narrowest case, which is in qualitative agreement with the energy definition of the PXR X-rays evaluated from geometrical consideration. The result also suggested that the wavelength dispersive X-ray absorption fine structure measurement associated with imaging technique is one of the promising applications of PXR. (author)

  6. High-resolution imaging of coronary calcifications by intense low-energy fluoroscopic X-ray obtained from synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Ohtsuka, S.; Sugishita, Y.; Takeda, T.; Itai, Y.; Tada, J.; Hyodo, K.; Ando, M. [Inst. of Clinical Medicine, Univ. of Tsukuba, Ibaraki (Japan). Dept. of Cardiology

    2000-07-01

    In order to obtain an intense monochromatic low-energy X-ray from synchrotron radiation (SR) and apply it to detect coronary calcifications, the SR beam was reflected with a silicon crystal to be expanded (150 mm in height and 80 mm in width) and to be monochromatized at an energy level of 37 keV. The X-ray was intermittently irradiated to obtain dynamic imaging of 30 images/s. Images were recorded by a digital fluorography system. The low-energy X-ray from SR sharply visualized calcification of coronary arteries, while conventional X-ray could not visualize coronary calcification. The intense monochromatic low-energy X-ray from SR is sensitive, has high-resolution for imaging coronary calcification and may serve as a screening method for coronary artery disease.

  7. Mobile and embedded fast high resolution image stitching for long length rectangular monochromatic objects with periodic structure

    Science.gov (United States)

    Limonova, Elena; Tropin, Daniil; Savelyev, Boris; Mamay, Igor; Nikolaev, Dmitry

    2018-04-01

    In this paper we describe stitching protocol, which allows to obtain high resolution images of long length monochromatic objects with periodic structure. This protocol can be used for long length documents or human-induced objects in satellite images of uninhabitable regions like Arctic regions. The length of such objects can reach notable values, while modern camera sensors have limited resolution and are not able to provide good enough image of the whole object for further processing, e.g. using in OCR system. The idea of the proposed method is to acquire a video stream containing full object in high resolution and use image stitching. We expect the scanned object to have straight boundaries and periodic structure, which allow us to introduce regularization to the stitching problem and adapt algorithm for limited computational power of mobile and embedded CPUs. With the help of detected boundaries and structure we estimate homography between frames and use this information to reduce complexity of stitching. We demonstrate our algorithm on mobile device and show image processing speed of 2 fps on Samsung Exynos 5422 processor

  8. Induction of DNA-protein cross-linking in Chinese hamster cells by monochromatic 365 and 405 NM ultraviolet light

    International Nuclear Information System (INIS)

    Han, A.; Peak, M.J.; Peak, J.G.

    1984-01-01

    The survival, the induction of DNA-protein cross-linking, and the number of T4-endonuclease sensitive sites were measured in Chinese hamster cells that had been irradiated with 365 and 405 nm monochromatic light. The survival measurements show that cells are somewhat less sensitive to 405 nm light than to 365 nm light. The difference is expressed predominantly in the shoulder widths of the survival curves, whereas the slopes of the two curves are about the same. Induction of pyrimidine dimers, as indicated by the number of endonuclease-sensitive sites, after exposures that produce about 10% survival is very low at 365 nm (approx. 4 endonuclease sites per 2 x 10 8 daltons), while no dimers are detected at 405 nm. In contrast, DNA-protein cross-links are induced rather effectively at either wavelength even after exposures that result in a relatively high survival (60-20%). These measurements support the conclusion that lethality in mammalian cells after irradiations with 365 or 405 nm light is caused by a nondimer damage, possibly DNA-protein cross-links. (author)

  9. Application of FEL technique for constructing high-intensity, monochromatic, polarized gamma-sources at storage rings

    Energy Technology Data Exchange (ETDEWEB)

    Saldin, E.L.; Schneidmiller, E.A.; Ulyanov, Yu.N. [Automatic Systems Corporation, Samara (Russian Federation)] [and others

    1995-12-31

    A possibility to construct high-intensity tunable monochromatic{gamma}-source at high energy storage rings is discussed. It is proposed to produce {gamma}-quanta by means of Compton backscattering of laser photons on electrons circulating in the storage. The laser light wavelength is chosen in such a way that after the scattering, the electron does not leave the separatrix. So as the probability of the scattering is rather small, energy oscillations are damped prior the next scattering. As a result, the proposed source can operate in {open_quotes}parasitic{close_quote} mode not interfering with the main mode of the storage ring operation. Analysis of parameters of existent storage rings (PETRA, ESRF, Spring-8, etc) shows that the laser light wavelength should be in infrared, {lambda}{approximately} 10 - 400 {mu}m, wavelength band. Installation at storage rings of tunable free-electron lasers with the peak and average output power {approximately} 10 MW and {approximately} 1 kW, respectively, will result in the intensity of the {gamma}-source up to {approximately} 10{sup 14}s{sup -1} with tunable {gamma}-quanta energy from several MeV up to several hundreds MeV. Such a {gamma}-source will reveal unique possibilities for precision investigations in nuclear physics.

  10. Electron magnetic chiral dichroism in CrO2 thin films using monochromatic probe illumination in a transmission electron microscope

    International Nuclear Information System (INIS)

    Loukya, B.; Zhang, X.; Gupta, A.; Datta, R.

    2012-01-01

    Electron magnetic chiral dichroism (EMCD) has been studied in CrO 2 thin films (with (100) and (110) growth orientations on TiO 2 substrates) using a gun monochromator in an aberration corrected transmission electron microscope operating at 300 kV. Excellent signal-to-noise ratio is obtained at spatial resolution ∼10 nm using a monochromatic probe as compared to conventional parallel illumination, large area convergent beam electron diffraction and scanning transmission electron microscopy techniques of EMCD. Relatively rapid exposure using mono probe illumination enables collection of EMCD spectra in total of 8–9 min in energy filtered imaging mode for a given Cr L 2,3 energy scan (energy range ∼35 eV). We compared the EMCD signal obtained by extracting the Cr L 2,3 spectra under three beam diffraction geometry of two different reciprocal vectors (namely g=110 and 200) and found that the g=200 vector enables acquisition of excellent EMCD signal from relatively thicker specimen area due to the associated larger extinction distance. Orbital to spin moment ratio has been calculated using EMCD sum rules for 3d elements and dichroic spectral features associated with CrO 2 are compared and discussed with XMCD theoretical spectra. - Highlights: ► Electron magnetic circular dichroism (EMCD) of CrO 2 thin film with two different orientations. ► Improved EMCD signal with Gun monochromator illumination. ► Improved EMCD signal with higher g vector.

  11. Neutron imaging of a commercial Li-ion battery during discharge: Application of monochromatic imaging and polychromatic dynamic tomography

    International Nuclear Information System (INIS)

    Butler, Leslie G.; Schillinger, Burkhard; Ham, Kyungmin; Dobbins, Tabbetha A.; Liu, Ping; Vajo, John J.

    2011-01-01

    A commercial lithium-ion polymer battery of prismatic construction was imaged in 2D by monochromatic neutron radiography at wavelengths around a LiC 6 spectral feature. Over the range of 3-4 A, the neutron attenuation spectra for charged and discharged batteries are distinctly different. In a real-time experiment, a battery was observed during discharge at wavelengths spanning the LiC 6 spectral feature and its disappearance monitored. No evidence of 'staging' was detected in this preliminary experiment. A similar battery was imaged in 3D with a new tomographic data acquisition scheme based on the Greek golden ratio; the scheme allows convenient post-processing to establish 'time windows' for 3D image reconstruction. The 3D images at 5% state of charge intervals are compromised by beam hardening, but still show some asymmetric battery volume change with discharge. Finally comments on the future of neutron imaging for battery experiments, whether at continuous sources at nuclear reactors or at pulsed spallation sources, are discussed.

  12. Multiple energy computed tomography for neuroradiology with monochromatic x-rays from the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Dilmanian, F.A.; Garrett, R.F.; Thomlinson, W.C.; Berman, L.E.; Chapman, L.D.; Gmuer, N.F.; Lazarz, N.M.; Moulin, H.R.; Oversluizen, T.; Slatkin, D.N.; Stojanoff, V.; Volkow, N.D.; Zeman, H.D.; Luke, P.N.; Thompson, A.C.

    1990-01-01

    Monochromatic and tunable 33--100 keV x-rays from the X17 superconducting wiggler of the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL) will be used for computed tomography (CT) of the human head and neck. The CT configuration will be one of a fixed horizontal fan-shaped beam and a seated rotating subject. The system, which is under development, will employ a two-crystal monochromator with an energy bandwidth of about 0.1%, and high-purity germanium linear array detector with 0.5 mm element width and 200 mm total width. Narrow energy bands not only eliminate beam hardening but are ideal for carrying out the following dial-energy methods: (a) dual-photon absorptiometry CT, that provides separate images of the low-Z and the intermediate-Z elements; and (b) K-edge subtraction CT of iodine and perhaps of heavier contrast elements. As a result, the system should provide ∼10-fold improvement in image contrast resolution and in quantitative precision over conventional CT. A prototype system for a 45 mm subject diameter will be ready in 1991, which will be used for studies with phantoms and small animals. The human imaging system will have a field of view of 200 mm. The in-plane spatial resolution in both systems will be 0.5 mm FWHM. 34 refs., 6 figs

  13. Development of quasi-monochromatic p-7Li neutron generating system for 80-210 MeV

    International Nuclear Information System (INIS)

    Nakao, Noriaki; Shibata, Tokushi; Nakamura, Takashi; Uwamino, Yoshitomo; Nakanishi, Noriyoshi; Kurosawa, Tadahiro; Kim, Unju.

    1996-01-01

    Recently the requirements for the experimental data on the response characteristics of neutron detector and the cross section for neutron generation by charged particles have been increasing for shield designing. Here, a system for quasi-monochromatic neutron generation was developed in the facility of ring-cyclotron in Institute of Physical and Chemical Sciences. In this study, H 2 + accelerated to an energy range of 80-135 MeV/n and P + to 150-210 MeV was irradiated to E4 beam course and NE102A plastic scintillator was used for monitoring the neutron flux. The amount of neutrons generated was estimated from the radioactivity of 7 Be produced in 7 Li-target. The neutron spectres thus estimated as an energy range of 80-210 MeV were presented and the lower limit of these spectres was about 20 MeV. The peaks in the range of 150 and 210 MeV were comparatively wide because of the inferiority of energy resolving power at a higher energy level. (M.N.)