WorldWideScience

Sample records for inches diameter breast

  1. Fabrication of 0.5-inch diameter FBR mixed oxide fuel pellets

    International Nuclear Information System (INIS)

    Rasmussen, D.E.; Benecke, M.W.; McCord, R.B.

    1979-01-01

    Large diameter (0.535 inch) mixed oxide fuel pellets for Fast Breeder Reactor application were successfully fabricated by the cold-press-and-sinter technique. Enriched UO 2 , PuO 2 -UO 2 , and PuO 2 -ThO 2 compositions were fabricated into nominally 90% theoretical density pellets for the UO 2 and PuO 2 -UO 2 compositions, and 88% and 93% T.D. for the PuO 2 -ThO 2 compositions. Some processing adjustments were required to achieve satisfactory pellet quality and density. Furnace heating rate was reduced from 200 to 50 0 C/h for the organic binder burnout cycle for the large, 0.535-inch diameter pellets to eliminate pellet cracking during sintering. Additional preslugging steps and die wall lubrication during pressing were used to eliminate pressing cracks in the PuO 2 -ThO 2 pellets

  2. DEVELOPMENT OF A NINE INCH DIAMETER, MACH 5.5, MONORAIL, ROCKET SLED.

    Science.gov (United States)

    A nine inch diameter monorail rocket sled was designed, fabricated and tested at Holloman Air Force Base. The vehicle was designed to allow easy...replacement of appendages which were subject to severe aerodynamic heating and/or high wear rates. The monorail vehicle as described was shown to be

  3. Interim results: fines recycle testing using the 4-inch diameter primary graphite burner

    International Nuclear Information System (INIS)

    Palmer, W.B.

    1975-05-01

    The results of twenty-two HTGR primary burner runs in which graphite fines were recycled pneumatically to the 4-inch diameter pilot-plant primary fluidized-bed burner are described. The result of the tests showed that zero fines accumulation can easily be achieved while operating at plant equivalent burn rates. (U.S.)

  4. The dimensional changes of a 24 inch diameter vessel during a campaign of successive glass making runs

    International Nuclear Information System (INIS)

    Chidley, B.E.

    1983-01-01

    Throughout the life of a 24 inch diameter Glass Making Vessel used on the inactive Harvest Vitrification Plant dimensional measurements have been recorded. When glass is present the diameter increases due to thermal stresses. Some permanent longitudinal extension (about 1%) occurred over the 20 runs comprising the glass-making campaign. (author)

  5. Preparatory Study of Photomultiplier Tubes of 10-inch and 3-inch Diameter for KM3NeT Underwater Neutrino Telescope

    International Nuclear Information System (INIS)

    Aiello, S.; Giordano, V.; Leonora, E.

    2015-01-01

    Large area photomultipliers are widely used in neutrino and astro-particle detectors to measure Cherenkov light in media like water or ice. The key element of these detectors are the so-called 'optical module', which consists of a photodetector enclosed in a transparent pressure-resistant container to protect it and ensure good light transmission. KM3NeT collaboration aims to construct an underwater 'hybrid' neutrino telescope by using two models detection unit. The 'tower' detection unit will be composed of large area 10-inch photomultipliers tube enclosed into 13-inch glass vessel sphere. In the 'string' detection unit instead, the light detector will be the 'digital optical module' (DOM) a glass vessel of 17-inch with 31 photomultipliers of 3- inch diameter looking upwards and downwards. The choice of two different kinds of photomultipliers, obliges us to investigate their main characteristics. Noise pulses at the anode of each photomultiplier strongly affect the performance of the detector. A large study was conducted on noise pulses of large area photomultipliers, considering time and charge distributions of dark pulses, pre-pulses, delayed pulses, and after-pulses. The contribution to noise pulses due to the presence of the external glass vessels was also studied. Moreover the presence of the Earth's magnetic field should modify quantities like gain and transit time spread in photomultipliers and we will deeply investigate on this. (authors)

  6. Seismic fragility test of a 6-inch diameter pipe system

    International Nuclear Information System (INIS)

    Chen, W.P.; Onesto, A.T.; DeVita, V.

    1987-02-01

    This report contains the test results and assessments of seismic fragility tests performed on a 6-inch diameter piping system. The test was funded by the US Nuclear Regulatory Commission (NRC) and conducted by ETEC. The objective of the test was to investigate the ability of a representative nuclear piping system to withstand high level dynamic seismic and other loadings. Levels of loadings achieved during seismic testing were 20 to 30 times larger than normal elastic design evaluations to ASME Level D limits would permit. Based on failure data obtained during seismic and other dynamic testing, it was concluded that nuclear piping systems are inherently able to withstand much larger dynamic seismic loadings than permitted by current design practice criteria or predicted by the probabilistic risk assessment (PRA) methods and several proposed nonlinear methods of failure analysis

  7. Tree diameter at breast height in relation to stump diameter by species group

    Science.gov (United States)

    Arthur G. Horn; Richard C. Keller

    1957-01-01

    A stump tally is one method of determining the volume of timber previously removed from an area in a logging operation. To estimate volume of standing timber from stumps, foresters must first know the relationship between stump diameters and tree diameters at breast height (d.b.h.).

  8. High spatial resolution gamma imaging detector based on a 5 inch diameter R3292 Hamamatsu PSPMT

    International Nuclear Information System (INIS)

    Wojcik, R.; Majewski, S.; Kross, B.; Weisenberger, A.G.; Steinbach, D.

    1998-01-01

    High resolution imaging gamma-ray detectors were developed using Hamamatsu's 5 inch diameter R3292 position sensitive PMT (PSPMT) and a variety of crystal scintillator arrays. Special readout techniques were used to maximize the active imaging area while reducing the number of readout channels. Spatial resolutions approaching 1 mm were obtained in a broad energy range from 20 to 511 keV. Results are also presented of coupling the scintillator arrays to the PMT via imaging light guides consisting of acrylic optical fibers

  9. Nuclear criticality safety calculational analysis for small-diameter containers

    International Nuclear Information System (INIS)

    LeTellier, M.S.; Smallwood, D.J.; Henkel, J.A.

    1995-11-01

    This report documents calculations performed to establish a technical basis for the nuclear criticality safety of favorable geometry containers, sometimes referred to as 5-inch containers, in use at the Portsmouth Gaseous Diffusion Plant. A list of containers currently used in the plant is shown in Table 1.0-1. These containers are currently used throughout the plant with no mass limits. The use of containers with geometries or material types other than those addressed in this evaluation must be bounded by this analysis or have an additional analysis performed. The following five basic container geometries were modeled and bound all container geometries in Table 1.0-1: (1) 4.32-inch-diameter by 50-inch-high polyethylene bottle; (2) 5.0-inch-diameter by 24-inch-high polyethylene bottle; (3) 5.25-inch-diameter by 24-inch-high steel can (open-quotes F-canclose quotes); (4) 5.25-inch-diameter by 15-inch-high steel can (open-quotes Z-canclose quotes); and (5) 5.0-inch-diameter by 9-inch-high polybottle (open-quotes CO-4close quotes). Each container type is evaluated using five basic reflection and interaction models that include single containers and multiple containers in normal and in credible abnormal conditions. The uranium materials evaluated are UO 2 F 2 +H 2 O and UF 4 +oil materials at 100% and 10% enrichments and U 3 O 8 , and H 2 O at 100% enrichment. The design basis safe criticality limit for the Portsmouth facility is k eff + 2σ < 0.95. The KENO study results may be used as the basis for evaluating general use of these containers in the plant

  10. Experimental and numerical approach on fracture behaviour of four inches diameter carbon-manganese cracked welded pipes in four point bending

    International Nuclear Information System (INIS)

    Semete, P.; Faidy, C.; Lautier, J.L.

    2001-01-01

    EDF has conducted a research programme to demonstrate the fracture resistance of carbon-manganese welded pipes. The main task of this programme consisted of testing three four inches diameter (114.3 mm O.D.) thin welded pipes (8.56 mm thick) which are representative of those of the sites. The three pipes were loaded under four point bending at a quasi-static rate at -20 C till their maximum bending moment was reached. This paper presents the experimental results, finite element calculations and their comparison with the simplified fracture assessment method of the RSE-M Code. (author)

  11. Project W320 52-inch diameter equipment container load test: Test report

    International Nuclear Information System (INIS)

    Bellomy, J.R.

    1995-01-01

    This test report summarizes testing activities and documents the results of the load tests performed on-site and off-site to structural qualify the 52-inch equipment containers designed and fabricated under Project W-320

  12. 40 CFR Table 25 to Subpart G of... - Effective Column Diameter (Fc)

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Effective Column Diameter (Fc) 25 Table..., Table 25 Table 25 to Subpart G of Part 63—Effective Column Diameter (Fc) Column type Fc (feet) 9-inch by 7-inch built-up columns 1.1 8-inch-diameter pipe columns 0.7 No construction details known 1.0 ...

  13. A study of performance and cost improvement potential of the 120 inch (3.05 m) diameter solid rocket motor. Volume 1: Summary report

    Science.gov (United States)

    Backlund, S. J.; Rossen, J. N.

    1971-01-01

    A parametric study of ballistic modifications to the 120 inch diameter solid propellant rocket engine which forms part of the Air Force Titan 3 system is presented. 576 separate designs were defined and 24 were selected for detailed analysis. Detailed design descriptions, ballistic performance, and mass property data were prepared for each design. It was determined that a relatively simple change in design parameters could provide a wide range of solid propellant rocket engine ballistic characteristics for future launch vehicle applications.

  14. Extraction of Trees Stem Diameters at Breast Height by Terrestrial Laser Sensor for Selective Cutting

    Directory of Open Access Journals (Sweden)

    Yili ZHENG

    2014-02-01

    Full Text Available In order to assist the operators of the logging harvester automatically and quickly select the appropriate trees for selective cutting, using two-dimensional laser scanner and inertial measurement system, the two-dimensional cloud points of the trunks at breast-height are obtained for several trees. After projection, clustering, linear transformation and fitting for the point clouds data, the parameters of the breast-height-diameters and center locations of the trees are obtained. The calculation is implemented in MATLAB by Polak-Ribiere-Polyak (PRP conjugate gradient algorithm and the result is shown in VC++ environment. Using this method, absolute errors of the breast-height- diameters and center locations are 2.3 cm and (12.4, 11.4 cm respectively, and meet the requirements on the automatically selective cutting of the logging harvester.

  15. Nineteen-Foot Diameter Explosively Driven Blast Simulator; TOPICAL

    International Nuclear Information System (INIS)

    VIGIL, MANUEL G.

    2001-01-01

    This report describes the 19-foot diameter blast tunnel at Sandia National Laboratories. The blast tunnel configuration consists of a 6 foot diameter by 200 foot long shock tube, a 6 foot diameter to 19 foot diameter conical expansion section that is 40 feet long, and a 19 foot diameter test section that is 65 feet long. Therefore, the total blast tunnel length is 305 feet. The development of this 19-foot diameter blast tunnel is presented. The small scale research test results using 4 inch by 8 inch diameter and 2 foot by 6 foot diameter shock tube facilities are included. Analytically predicted parameters are compared to experimentally measured blast tunnel parameters in this report. The blast tunnel parameters include distance, time, static, overpressure, stagnation pressure, dynamic pressure, reflected pressure, shock Mach number, flow Mach number, shock velocity, flow velocity, impulse, flow duration, etc. Shadowgraphs of the shock wave are included for the three different size blast tunnels

  16. SAFT 4{1/2} inch nickel hydrogen battery cells

    Energy Technology Data Exchange (ETDEWEB)

    Duquesne, D.; Lacout, B.; Sennet, A. [SAFT Advanced Batteries, Poitiers (France)

    1995-12-31

    SAFT Advanced Batteries has now produced over 400 high capacity 4{1/2} inch Nickel Hydrogen Battery Cells for flight programs. The 4.5 inch diameter, rabbit-ear cell design is designed to provide the anticipated energy required at the lowest practical weight. SAFT has incorporated into the design of the dry-powder nickel electrode, truly hermetic ceramic to metal seals, qualified terminal feedthroughs, high reliability mechanical design, composite pure platinum negative electrode, and zircar separator, plus more than 25 years experience in aerospace nickel cell technology, resulting in a 4{1/2} inch configuration with the 3{1/2} inch cell design carryover heritage. General performance requirements for GEO missions that SAFT cells meet are 15 years in orbit lifetime, 80% DOD, low mass to energy ratios, and flexible capacity by modifying number of electrodes in the stack. This design is qualified for geostationary orbits based on SAFT`s 3{1/2} inch qualification heritage, design verification, and cycling performed by customer Space Systems/LORAL in support of the INTELSAT VIIA and N-STAR flight programs.

  17. Growth of magnesium diboride films on 2 inch diameter copper discs by hybrid physical–chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Withanage, Wenura K.; Xi, X. X.; Nassiri, Alireza; Lee, Namhoon; Wolak, Matthäus A.; Tan, Teng; Welander, Paul B.; Franzi, Matthew; Tantawi, Sami; Kustom, Robert L.

    2017-02-16

    Magnesium diboride (MgB2) coating is a potential candidate to replace bulk niobium (Nb) for superconducting radio frequency cavities due to the appealing superconducting properties of MgB2. MgB2 coating on copper may allow cavity operation near 20–25 K as a result of the high transition temperature (T c) of MgB2 and excellent thermal conductivity of Cu. We have grown MgB2 films on 2 inch diameter Cu discs by hybrid physical–chemical vapor deposition for radio frequency characterization. Structural and elemental analyses showed a uniform MgB2 coating on top of a Mg–Cu alloy layer with occasional intrusion of Mg–Cu alloy regions. High T c values of around 37 K and high critical current density (J c) on the order of 107 A cm-2 at zero field were observed. Radio frequency measurements at 11.4 GHz confirmed a high T c and showed a quality factor (Q 0) much higher than for Cu and close to that of Nb.

  18. Growth of magnesium diboride films on 2 inch diameter copper discs by hybrid physical-chemical vapor deposition

    Science.gov (United States)

    Withanage, Wenura K.; Xi, X. X.; Nassiri, Alireza; Lee, Namhoon; Wolak, Matthäus A.; Tan, Teng; Welander, Paul B.; Franzi, Matthew; Tantawi, Sami; Kustom, Robert L.

    2017-04-01

    Magnesium diboride (MgB2) coating is a potential candidate to replace bulk niobium (Nb) for superconducting radio frequency cavities due to the appealing superconducting properties of MgB2. MgB2 coating on copper may allow cavity operation near 20-25 K as a result of the high transition temperature (T c) of MgB2 and excellent thermal conductivity of Cu. We have grown MgB2 films on 2 inch diameter Cu discs by hybrid physical-chemical vapor deposition for radio frequency characterization. Structural and elemental analyses showed a uniform MgB2 coating on top of a Mg-Cu alloy layer with occasional intrusion of Mg-Cu alloy regions. High T c values of around 37 K and high critical current density (J c) on the order of 107 A cm-2 at zero field were observed. Radio frequency measurements at 11.4 GHz confirmed a high T c and showed a quality factor (Q 0) much higher than for Cu and close to that of Nb.

  19. Test procedure for the Master-Lee and the modified Champion four inch hydraulic cutters

    International Nuclear Information System (INIS)

    Crystal, J.B.

    1995-01-01

    The Master-Lee and the modified Champion 4 Inch hydraulic cutters are being retested to gather and document information related to the following: determine if the Master-Lee cutters will cut the trunnions of an Aluminum fuel canister and a Stainless Steel fuel canister; determine if the Master-Lee cutters will cut 1 1/2 inch diameter fire hose; determine if the modified Champion 4 inch blade will cut sections of piping; and determine the effectiveness of the centering device for the Champion 4 Inch cutters. Determining the limitations of the hydraulic cutter will aid in the process of debris removal in the K-Basin. Based on a previous test, the cutters were returned to the manufacturer for modifications. The modifications to the Champion 4 Inch Cutter and further testing of the Master-Lee Cutter are the subjects of these feature tests

  20. Shiitake mushroom production on small diameter oak logs in Ohio

    Science.gov (United States)

    S.M. Bratkovich

    1991-01-01

    Yields of different strains of shiitake mushrooms (Lentinus edodes) were evaluated when produced on small diameter oak logs in Ohio. Logs averaging between 3-4 inches in diameter were inoculated with four spawn strains in 1985.

  1. Am/Cm TTR testing - 3/8-inch glass beads evaluation in CIM5

    International Nuclear Information System (INIS)

    Witt, D. C.

    2000-01-01

    To facilitate the procurement and handling of the glass former for Am/Cm vitrification in the F-Canyon MPPF, 1/4 inch and 3/8 inch diameter glass beads were purchased from Corning for evaluation in the 5 inch Cylindrical Induction Melter (CIM5). Prior to evaluating the beads in the CIM5, tests were conducted in the Drain Tube Test Stand (DTTS) with 1/4 inch beads, 3/8 inch beads, and a 50/50 mixture to identify any process concerns. Results of the DTTS tests are summarized in Attachment 1. A somewhat larger volume expansion was experienced in all three DTTS runs as compared to a standard run using cullet. Further testing of the use of glass beads in the CIM5 was requested by the Design Authority as Task 1.02 of Technical Task Request 99-MNSS/SE-006. Since the Technical Task Plan was not yet approved, the completion of this task was conducted under an authorization request approved by the SRTC Laboratory Director, S. Wood. This request is included as Attachment 2

  2. Development and evaluation of height diameter at breast models for native Chinese Metasequoia.

    Science.gov (United States)

    Liu, Mu; Feng, Zhongke; Zhang, Zhixiang; Ma, Chenghui; Wang, Mingming; Lian, Bo-Ling; Sun, Renjie; Zhang, Li

    2017-01-01

    Accurate tree height and diameter at breast height (dbh) are important input variables for growth and yield models. A total of 5503 Chinese Metasequoia trees were used in this study. We studied 53 fitted models, of which 7 were linear models and 46 were non-linear models. These models were divided into two groups of single models and multivariate models according to the number of independent variables. The results show that the allometry equation of tree height which has diameter at breast height as independent variable can better reflect the change of tree height; in addition the prediction accuracy of the multivariate composite models is higher than that of the single variable models. Although tree age is not the most important variable in the study of the relationship between tree height and dbh, the consideration of tree age when choosing models and parameters in model selection can make the prediction of tree height more accurate. The amount of data is also an important parameter what can improve the reliability of models. Other variables such as tree height, main dbh and altitude, etc can also affect models. In this study, the method of developing the recommended models for predicting the tree height of native Metasequoias aged 50-485 years is statistically reliable and can be used for reference in predicting the growth and production of mature native Metasequoia.

  3. Development and evaluation of height diameter at breast models for native Chinese Metasequoia.

    Directory of Open Access Journals (Sweden)

    Mu Liu

    Full Text Available Accurate tree height and diameter at breast height (dbh are important input variables for growth and yield models. A total of 5503 Chinese Metasequoia trees were used in this study. We studied 53 fitted models, of which 7 were linear models and 46 were non-linear models. These models were divided into two groups of single models and multivariate models according to the number of independent variables. The results show that the allometry equation of tree height which has diameter at breast height as independent variable can better reflect the change of tree height; in addition the prediction accuracy of the multivariate composite models is higher than that of the single variable models. Although tree age is not the most important variable in the study of the relationship between tree height and dbh, the consideration of tree age when choosing models and parameters in model selection can make the prediction of tree height more accurate. The amount of data is also an important parameter what can improve the reliability of models. Other variables such as tree height, main dbh and altitude, etc can also affect models. In this study, the method of developing the recommended models for predicting the tree height of native Metasequoias aged 50-485 years is statistically reliable and can be used for reference in predicting the growth and production of mature native Metasequoia.

  4. Operational maneuvers and pipelines activities repairs for the 32 inches scraper tool recovering

    Energy Technology Data Exchange (ETDEWEB)

    Valdivia, Jose; Salguero, Luis; Villanueva, Pedro [Compania Operadora del Gas Amazonas, Lima (Peru)

    2009-07-01

    Transportadora de Gas del Peru and the Compania Operadora de Gas del Amazonas, responsible companies of the transport, operation and maintenance of the pipelines who transport natural gas and natural gas liquids respectively of the Camisea Project - Peru, following the internal policies and the maintenance plan of the pipeline transportation system was planned the activities for the internal pipeline inspection of these activities for 729.3 Km of natural gas pipeline covering diameters of 32 inches, 24 inches and 18 inches. After the first run of the cleaning tool, was scheduled the launch of the dummy scraper (scraper tool) along to the first 210 Km of the 32 inches natural gas pipeline , given changes in elevation along the trace and the low flow of transport. This scraper tool could not reach the final destination. After many series operational maneuvers as venting, creation of differential pressure in valves, the scraper tool only reach the first 75 Km of the trace. After an exhaustive analysis of trending pressure variations, it was concluded that this scraper showed intermittent progress of short durations, concluding that this scraper had not reach the next check point. In this way was decided to conduct operational maneuvers in order to locate, relocated and retrieve the scrapper tool from de 32 inches natural gas pipeline. (author)

  5. Development of a 10-inch HPD with integrated readout electronics

    CERN Document Server

    Braem, André; Joram, C; Séguinot, Jacques; Weilhammer, Peter; Giunta, M; Malakhov, N; Menzione, A; Pegna, R; Piccioli, A; Raffaelli, F; Sartori, G

    2003-01-01

    A round 10-in. diameter Hybrid Photodiode (HPD) with spherical entrance window is under development for Cherenkov imaging applications in cosmic ray astronomy. The HPD adopts the fountain focusing electron optics, which, as already demonstrated in the 5 inch Pad HPD, allows for a linear demagnification of the image over practically the full tube diameter. Self-triggering front-end electronics providing also sparse readout capability, has been tested. High-efficiency Rb//2Te cathodes have been produced on a UV extended borosilicate glass windows with very thin conductive underlayers of Indium Tin Oxide. We report on the design of the 10- in. HPD, the fabrication procedure and first tests of a 5-in. HPD with Rb//2Te photocathode and 2048 channels.

  6. Comparision of Incidental Reflection From Containerized Maintenance/Housekeeping Solutions and One Inch of Water

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Bryan Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); MacQuigg, Michael Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wysong, Andrew Russell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-12-15

    This document addresses the incidental reflector reactivity worth of containerized maintenance/housekeeping fluids for use in PF-4 at Los Alamos National Laboratory (LANL). The intent of the document is to analyze containerized maintenance/housekeeping fluids which will be analyzed as water that may be present under normal conditions of an operation. The reactivity worth is compared to the reactivity worth due to I-inch of close-fitting 4n water reflection and I-inch of close-fitting radial water reflection. Both have been used to bound incidental reflection by 2-liter bottles in criticality safety evaluations. The conclusion is that, when the maintenance/housekeeping fluids are containerized the reactivity increase from a configuration which is bounding of normal conditions (up to eight bottles modeled with 2-liters of solution at varying diameter) is bound by I-inch of close fitting 4n water relection.

  7. Project Waiver of American Iron and Steel Requirements to the Napa Sanitation District for 24-Inch Diameter Butterfly Valves

    Science.gov (United States)

    Waiver approval by EPA pursuant to the American Iron and Steel Requirements of the Clean Water Act Section 608 to the Napa Sanitation District in California for the purchase of 24-inch butterfly valves.

  8. Project W420 Air Sampler Probe Placement Qualification Tests for Four 6-Inch Diameter Stacks: 296-A-25, 296-B-28, 296-S-22, and 296-T-18

    International Nuclear Information System (INIS)

    Maughan, A.D.; Glissmeyer, J.A.

    1998-01-01

    The W420 project covers the upgrading of effluent monitoring systems at six ventilation exhaust stacks in tank-farm facilities at the U.S. Department of Energy's Hanford Site. The discharge stacks of five of the six systems will be completely replaced. Four of these (296-A-25, 296-B-28, 296-S-22, and 296-T-18) will be of the same size, 6-inches in diameter and about 12-ft high. This report documents tests that were conducted to verify that these four stacks meet the applicable regulatory criteria regarding the placement of the air sampling probe. These criteria ensure that the contaminants in the stack are well mixed with the airflow at the location of the probe such that the extracted sample represents the whole. There are also criteria addressing the transport of the sample to the collection device. These are not covered in this report, but will need to be addressed later. These tests were conducted by Pacific Northwest National Laboratory on a full-scale model of the 6-inch stick. The sequence of tests addresses the acceptability of the flow angle relative to the probe and the uniformity of air velocity and gaseous and particle tracers in the cross section of the stack. All tests were successful, and all acceptance criteria were met

  9. Production and cost of harvesting, processing, and transporting small-diameter (< 5 inches) trees for energy

    Science.gov (United States)

    Fei Pan; Han-Sup Han; Leonard R. Johnson; William J. Elliot

    2008-01-01

    Dense, small-diameter stands generally require thinning from below to improve fire-tolerance. The resulting forest biomass can be used for energy production. The cost of harvesting, processing, and transporting small-diameter trees often exceeds revenues due to high costs associated with harvesting and transportation and low market values for forest biomass....

  10. Comparison of four harvesting systems in a loblolly pine plantation

    Science.gov (United States)

    J. Klepac; Dana Mitchell

    2016-01-01

    Felling and skidding operations were monitored while clearcut harvesting a 12-acre area of a 14-year old loblolly pine (Pinus taeda) plantation. The study area contained 465 trees per acre for trees 2.0 inches Diameter at Breast Height (DBH) and larger with a Quadratic Mean Diameter (QMD) of 7.26 inches. Two feller-bunchers (tracked and rubber-tired) and two skidders (...

  11. Reduction of the Areolar Diameter After Ultrasound-Assisted Liposuction for Gynecomastia.

    Science.gov (United States)

    Keskin, Mustafa; Sutcu, Mustafa; Hanci, Mustafa; Cigsar, Bulent

    2017-08-01

    One of the clinical aspects characterizing gynecomastia is the enlargement of the nipple-areolar complex (NAC) due to hypertrophic breast glands, and the excessive fatty tissue underneath. The purpose of this study was to quantify the reduction of the areolar diameter after ultrasound-assisted liposuction (UAL) of the male breast. The horizontal diameters of the NACs of 30 men who underwent UAL were measured before surgery, 1 month after surgery and 6 months after surgery in a standard fashion. Those patients with surgical gland removals of any kind were not included in this study. The mean age of the patients was 27.9 years, and all of the patients had bilateral grade I, II, or III gynecomastia. The mean diameter of the NACs before surgery was 35.36 mm (range, 26-55 mm), and after surgery, the mean diameter of the NACs was initially reduced to 28.8 mm (range, 23-44 mm) and later to 28.57 mm (range, 23-42 mm). The mean volume of breast tissue aspirated was 382 mL per breast, and the percentage of reduction was 17.3%. The reduction of areola diameter was statistically significant after first month. A significant positive correlation was identified between the liposuction volume and areolar diameter reduction. In cases of gynecomastia, the removal of the glandular and fatty tissue underneath the areola releases the expanding forces and pressure that enlarge it. In many cases of gynecomastia, UAL alone is effective in reducing the size of the NAC and allows the surgeon to avoid placing scars on the breast.

  12. The effects of Earth's magnetic field on 3-inch diameter photomultipliers used in KM3NeT neutrino telescope

    Directory of Open Access Journals (Sweden)

    Giordano V.

    2016-01-01

    Full Text Available The KM3NeT neutrino telescope will be the largest underwater neutrino telescope and will be located in the abyss of the Mediterranean Sea. In neutrino telescopes the key element of the detector is the optical module and for KM3NeT it consists of 31 PMTs stored inside a transparent pressure-resistant glass sphere of 17-inch that serves as mechanical protection while ensuring good light transmission. Since the PMTs installed into an underwater neutrino telescope can change their orientation because of movements of the detector structure due to sea currents, the influence of Earth's magnetic field has been investigated. Magnetic shielding by means of a mu-metal cage is used to reduce magnetic effects and to make the response of the PMT sufficiently orientation independent. In order to quantify the effect on magnetic field, we compared measurements on variation of gain, transit time spread and detection efficiency for a 3-inch PMT in shielded and unshielded condition at 3 PMT inclinations. Data shows that variations are sufficiently low especially for timing properties.

  13. A technique to identify annual growth rings in Eucalyptus grandis using annual measurements of diameter at breast height and gamma ray densitometry

    CSIR Research Space (South Africa)

    Naidoo, Sasha

    2010-06-01

    Full Text Available A technique was developed to identify annual growth rings in E. grandis using a combination of annual measurements of diameter at breast height (DBH) from permanent sample plot (PSP) datasets and bark-pith density profiles. By assessing the pattern...

  14. New Hybrid Algorithms for Estimating Tree Stem Diameters at Breast Height Using a Two Dimensional Terrestrial Laser Scanner

    Directory of Open Access Journals (Sweden)

    Jianlei Kong

    2015-07-01

    Full Text Available In this paper, a new algorithm to improve the accuracy of estimating diameter at breast height (DBH for tree trunks in forest areas is proposed. First, the information is collected by a two-dimensional terrestrial laser scanner (2DTLS, which emits laser pulses to generate a point cloud. After extraction and filtration, the laser point clusters of the trunks are obtained, which are optimized by an arithmetic means method. Then, an algebraic circle fitting algorithm in polar form is non-linearly optimized by the Levenberg-Marquardt method to form a new hybrid algorithm, which is used to acquire the diameters and positions of the trees. Compared with previous works, this proposed method improves the accuracy of diameter estimation of trees significantly and effectively reduces the calculation time. Moreover, the experimental results indicate that this method is stable and suitable for the most challenging conditions, which has practical significance in improving the operating efficiency of forest harvester and reducing the risk of causing accidents.

  15. Size of silicon strip sensor from 6 inch wafer (right) compared to that from a 4 inch wafer (left).

    CERN Multimedia

    Honma, Alan

    1999-01-01

    Silicon strip sensors made from 6 inch wafers will allow for much larger surface area coverage at a reduced cost per unit surface area. A prototype sensor of size 8cm x 11cm made by Hamamatsu from a 6 inch wafer is shown next to a traditional 6cm x 6cm sensor from a 4 inch wafer.

  16. Approximation of the breast height diameter distribution of two-cohort stands by mixture models III Kernel density estimators vs mixture models

    Science.gov (United States)

    Rafal Podlaski; Francis A. Roesch

    2014-01-01

    Two-component mixtures of either the Weibull distribution or the gamma distribution and the kernel density estimator were used for describing the diameter at breast height (dbh) empirical distributions of two-cohort stands. The data consisted of study plots from the Å wietokrzyski National Park (central Poland) and areas close to and including the North Carolina section...

  17. Pipe rupture test results; 4 inch pipe whip tests under BWR operational condition-clearance parameter experiments

    International Nuclear Information System (INIS)

    Ueda, Syuzo; Isozaki, Toshikuni; Miyazaki, Noriyuki; Kurihara, Ryoichi; Kato, Rokuro; Saito, Kazuo; Miyazono, Shohachiro

    1981-05-01

    The purpose of pipe rupture studies in JAERI is to perform the model tests on pipe whip, restraint behavior, jet impingement and jet thrust force, and to establish the computational method for analyzing these phenomena. This report describes the experimental results of pipe whip on the pipe specimens of 4 inch in diameter under BWR condition on which the pressure is 6.77 MPa and the temperature is 285 0 C. The pipe specimens were 114.3 mm (4 inch) in diameter and 8.6 mm in thickness and 4500 mm in length. Four pipe whip restraints used in the tests were the U-bar type of 8 mm in diameter and fabricated from type 304 stainless steel. The experimental parameter was the clearance (30, 50 and 100 mm). The dynamic strain behavior of the pipe specimen and the restraints was investigated by strain gages and their residual deformation was obtained by measuring marking points provided on their surface. The Pressure-time history in the pipe specimens was also obtained by pressure gages. The maximum pipe strain is caused near the restraints and increases with increase of the clearance. The experimental results of pipe whip tests indicate the effectiveness of pipe whip restraints. The ratio of absorbed strain energy of the pipe specimen to that of the restraints is nearly constant for different clearances at the overhang length of 400 mm. (author)

  18. The impact of wire caliber on ERCP outcomes: a multicenter randomized controlled trial of 0.025-inch and 0.035-inch guidewires.

    Science.gov (United States)

    Bassan, Milan S; Sundaralingam, Praka; Fanning, Scott B; Lau, James; Menon, Jayaram; Ong, Evan; Rerknimitr, Rungsun; Seo, Dong-Wan; Teo, Eng Kiong; Wang, Hsiu-Po; Reddy, D Nageshwar; Goh, Khean Lee; Bourke, Michael J

    2018-06-01

    Wire-guided biliary cannulation has been demonstrated to improve cannulation rates and reduce post-ERCP pancreatitis (PEP), but the impact of wire caliber has not been studied. This study compares successful cannulation rates and ERCP adverse events by using a 0.025-inch and 0.035-inch guidewire. A randomized, single blinded, prospective, multicenter trial at 9 high-volume tertiary-care referral centers in the Asia-Pacific region was performed. Patients with an intact papilla and conventional anatomy who did not have malignancy in the head of the pancreas or ampulla and were undergoing ERCP were recruited. ERCP was performed by using a standardized cannulation algorithm, and patients were randomized to either a 0.025-inch or 0.035-inch guidewire. The primary outcomes of the study were successful wire-guided cannulation and the incidence of PEP. Overall successful cannulation and ERCP adverse events also were studied. A total of 710 patients were enrolled in the study. The primary wire-guided biliary cannulation rate was similar in 0.025-inch and 0.035-inch wire groups (80.7% vs 80.3%; P = .90). The rate of PEP between the 0.025-inch and the 0.035-inch wire groups did not differ significantly (7.8% vs 9.3%; P = .51). No differences were noted in secondary outcomes. Similar rates of successful cannulation and PEP were demonstrated in the use of 0.025-inch and 0.035-inch guidewires. (Clinical trial registration number: NCT01408264.). Copyright © 2018. Published by Elsevier Inc.

  19. IMPACT TESTING OF MATERIALS USING AN EIGHT-INCH AIR GUN AND COMPUTER REDUCTION OF DATA

    Energy Technology Data Exchange (ETDEWEB)

    Thorne, L. F.

    1973-10-01

    A mechanical shock actuator has been converted into an air gun capable of firing 8-inch-·diameter (20.32 cm) projectiles to velocities exceeding 1000 fps (304.8 m/ s). This new capability has been used to study the effect of impact velocity upon the energy.absorbed by crushable materials. Shockpulse data is reduced by computer techniques and test results are displayed in either tabular or graphic format by use of the C DC 6600 Calcomp plotter.

  20. A small diameter, flexible, all attitude, self-contained germanium spectrometer. Operator's manual

    International Nuclear Information System (INIS)

    Bordzindki, R.L.; Lepel, E.A.; Reeves, J.H.; Kohli, R.

    1997-05-01

    The end of the Cold War has brought about tremendous changes in the nuclear complex of the Department of Energy. One of the many changes has been the shutdown or decommissioning of many facilities that performed nuclear work. One of the steps in the process of decommissioning a facility involves the decontamination or removal of drain lines or pipes that may have carried radioactive materials at one time. The removal of all these pipes and drain lines to a nuclear disposal facility could be quite costly. It was suggested by Pacific Northwest National Laboratory (PNNL) that a germanium spectrometer could be built that could fit through straight pipes with a diameter as small as 5.08 cm (2 inches) and pass through curved pipes with a diameter as small as 7.6 cm (3 inches) such as that of a 3-inch p-trap in a drain line. The germanium spectrometer could then be used to simultaneously determine all gamma-ray emitting radionuclides in or surrounding the pipe. By showing the absence of any gamma-ray emitting radionuclides, the pipes could then be reused in place or disposed of as non-radioactive material, thus saving significantly in disposal costs. A germanium spectrometer system has been designed by PNNL and fabricated by Princeton Gamma Tech (PGT) that consists of three segments, each 4.84 cm in diameter and about 10 cm in length. Flexible stainless steel bellows were used to connect the segments. Segment 1 is a small liquid nitrogen reservoir. The reservoir is filled with a sponge-like material which enables the detector to be used in any orientation. A Stirling cycle refrigerator is under development which can replace the liquid nitrogen reservoir to provide continuous cooling and operation

  1. Relationships between diameter and height of trees in natural ...

    African Journals Online (AJOL)

    Relationships between diameter and height of trees in natural tropical forest in Tanzania. Wilson A Mugasha, Ole M Bollandsås, Tron Eid. Abstract. The relationship between tree height (h) and tree diameter at breast height (dbh) is an important element describing forest stands. In addition, h often is a required variable in ...

  2. Bark thickness related to tree diameter in sugar maple (Acer saccharum Marsh.)

    Science.gov (United States)

    H. Clay Smith

    1969-01-01

    Bark thickness for sugar maple trees in Vermont was found to be related to tree diameter at breast height (d.b.h.). The relationship was positive-as the diameter increased, the bark thickness increased.

  3. 8-inch IBM floppy disk

    CERN Multimedia

    1971-01-01

    The 8-inch floppy disk was a magnetic storage disk for the data introduced commercially by IBM in 1971. It was designed by an IBM team as an inexpensive way to load data into the IBM System / 370. Plus it was a read-only bare disk containing 80 KB of data. The first read-write version was introduced in 1972 by Memorex and could contain 175 KB on 50 tracks (with 8 sectors per track). Other improvements have led to various coatings and increased capacities. Finally, it was surpassed by the mini diskette of 5.25 inches introduced in 1976.

  4. Refurbishment and modification of existing protective shipping packages (for 30-inch UF{sub 6} cylinders) per USDOT specification No. USA-DOT-21PF-1A

    Energy Technology Data Exchange (ETDEWEB)

    Housholder, W.R. [Nuclear Containers, Incorporated, Elizabethton, TN (United States)

    1991-12-31

    This paper addresses the refurbishment procedures for existing shipping containers for 30-inch diameter UF{sub 6} cylinders in accordance with DOT Specification 21PF-1 and the criteria used to determine rejection when such packages are unsuitable for refurbishment.

  5. Structural reinforcement of a {theta}16 inches tee made during operation with composite material

    Energy Technology Data Exchange (ETDEWEB)

    Beim, Andre [Tresca Engenharia Ltda., Sao Paulo, SP (Brazil); Vilani, Eduardo Cesar [Rust Engenharia Ltda., Diadema, SP (Brazil)

    2009-07-01

    An industrial installation went through a turnaround to increase capacity. A tie-in line had to be made for this, and a 16 inches diameter branch was required to be made on an existing 16 inches pipe. The joining of these elements resulted in a 'tee' that was supposed to receive a reinforcement plate. This reinforcement plate was not installed before the plant start-up. Code calculations and a finite element stress analysis showed that reinforcement was necessary. The only viable solution was the application of a composite material reinforcement, designed to substitute the missing reinforcement plate, and reduce the stresses to allowable levels. A new finite element stress analysis was made to determine the required thickness of this reinforcement. The first part of this work shows the results of the finite element stress analysis. Figures with stress contours of the analyses show the results. The second part shows the details of the installation of the reinforcement, which was made during normal operation of the plant. Pictures illustrate the main steps of the installation procedure. (author)

  6. 83-inch cyclotron research program. Final report

    International Nuclear Information System (INIS)

    Parkinson, W.C.

    1983-07-01

    In June of 1960 the US Atomic Energy Commission authorized the construction of a modern variable energy cyclotron facility at The University of Michigan to be used for research in nuclear spectroscopy. The Legislature of the State of Michigan made available funds for construction of a building to house the 83-inch cyclotron and auxiliary equipment as well as the University's remodeled 42-inch cyclotron. The research program centered around the 83-inch cyclotron was funded by the AEC and its successors, the Energy Research and Development Administration (ERDA) and the Department of Energy (DOE), from September 1964 through March 1977. The program represented a continuation of the research effort using the 42-inch cyclotron facility which had been supported continuously by the AEC since February 1950. This final report to DOE briefly describes the research facility, the research program, and highlights the principal accomplishments of the effort. It begins with a historical note to place this effort within the context of nuclear physics research in the Department of Physics of the University of Michigan

  7. Investigation of the ductile fracture properties of Type 304 stainless steel plate, welds, and 4-inch pipe

    International Nuclear Information System (INIS)

    Vassilaros, M.G.; Hays, R.A.; Gudas, J.P.

    1985-01-01

    J-integral fracture toughness tests were performed on welded 304 stainless steel 2-inch plate and 4-inch diameter pipe. The 2-inch plate was welded using a hot-wire automatic gas tungsten arc process. The tests were performed at 550 0 F, 300 0 F and room temperature. The results of the J-integral tests indicate that the Jsub(Ic) of the base plate ranged from 4400 to 6100 in lbs/in 2 at 550 0 F. The Jsub(Ic) values for the tests performed at 300 0 F and room temperature were beyond the measurement capacity of the specimens and appear to indicate that Jsub(Ic) was greater than 8000 in lb/in 2 . The J-integral tests performed on the weld metal specimens indicate that the Jsub(Ic) values ranged from 930 to 2150 in lbs/in 2 at 550 0 F. The Jsub(Ic) values of the weld metal specimens tested at 300 0 F and room temperature were 2300 and 3000 in lbs/in 2 respectively. One HAZ specimen was tested at 550 0 F and found to have a Jsub(Ic) value of 2980 in lbs/in 2 which indicates that the HAZ is an average of the base metal and weld metal toughness. These test results indicate that there is a significant reduction in the initiation fracture toughness as a result of welding. The second phase of this task dealt with the fracture toughness testing of 4-inch diameter 304 stainless steel pipes containing a gas tungsten arc weld. The pipes were tested at 550 0 F in four point bending. Three tests were performed, two with a through wall flaw growing circumferentially and the third pipe had a part through radial flaw in combination with the circumferential flaw. These tests were performed using unloading compliance and d.c. potential drop crack length estimate methods. The results of these tests indicate that the presence of a complex crack (radial and circumferential) reduces in the initiation toughness and the tearing modulus of the pipe material compared to a pipe with only a circumferentially growing crack. (orig.)

  8. Multicenter prospective study of magnetic resonance imaging prior to breast-conserving surgery for breast cancer.

    Science.gov (United States)

    Liu, Qian; Liu, Yinhua; Xu, Ling; Duan, Xuening; Li, Ting; Qin, Naishan; Kang, Hua; Jiang, Hongchuan; Yang, Deqi; Qu, Xiang; Jiang, Zefei; Yu, Chengze

    2014-01-01

    This multicenter prospective study aimed to assess the utility of dynamic enhanced magnetic resonance imaging (MRI) prior to breast-conserving surgery for breast cancer. The research subjects were drawn from patients with primary early resectable breast cancer treated in the breast disease centers of six three-level hospitals in Beijing from 1 January 2010 to 31 December 2012. The participants were allocated to a breast-conserving surgery group (breast-conserving group) or a total mastectomy group (total mastectomy group). Enhanced MRI was used to measure breast volume, longest diameter of tumor and tumor volume. The correlations between these measurements and those derived from histopathologic findings were assessed. The relationships between the success rate of breast-conserving surgery and MRI- and pathology-based measurement results were statistically analyzed in the breast-conserving group. The study included 461 cases in the total mastectomy group and 195 in the breast-conserving group. Allocation to these groups was based on clinical indications and patient preferences. The cut-off for concurrence between MRI- and pathology-based measurements of the longest diameter of tumor was set at 0.3 cm. In the total mastectomy group, the confidence interval for 95% concurrence of these measurements was 35.41%-44.63%. Correlation coefficients for MRI and histopathology-based measurements of breast volume, tumor volume and tumor volume/breast volume ratio were r = 0.861, 0.569, and 0.600, respectively (all P surgery were 100% and 88.54%, respectively. There were significant correlations between dynamic enhanced MRI- and histopathology-based measurements of the longest diameter of breast lesions, breast and tumor volumes, and breast volume/tumor volume ratios. Preoperative MRI examination improves the success rate of breast-conserving surgery.

  9. Test Report for MSFC Test No. 83-2: Pressure scaled water impact test of a 12.5 inch diameter model of the Space Shuttle solid rocket booster filament wound case and external TVC PCD

    Science.gov (United States)

    1983-01-01

    Water impact tests using a 12.5 inch diameter model representing a 8.56 percent scale of the Space Shuttle Solid Rocket Booster configuration were conducted. The two primary objectives of this SRB scale model water impact test program were: 1. Obtain cavity collapse applied pressure distributions for the 8.56 percent rigid body scale model FWC pressure magnitudes as a function of full-scale initial impact conditions at vertical velocities from 65 to 85 ft/sec, horizontal velocities from 0 to 45 ft/sec, and angles from -10 to +10 degrees. 2. Obtain rigid body applied pressures on the TVC pod and aft skirt internal stiffener rings at initial impact and cavity collapse loading events. In addition, nozzle loads were measured. Full scale vertical velocities of 65 to 85 ft/sec, horizontal velocities of 0 to 45 ft/sec, and impact angles from -10 to +10 degrees simulated.

  10. Ductile fracture behavior of 6-inch diameter type 304 stainless steel and STS 42 carbon steel piping containing a through-wall or part-through crack

    International Nuclear Information System (INIS)

    Shibata, Katsuyuki; Ohba, Toshihiro; Kawamura, Takaichi; Miyazono, Shohachiro; Kaneko, Tadashi; Yokoyama, Norio.

    1986-05-01

    The double ended guillotine break philosophy in the design base accident of the nuclear power plant is considered to be overly conservative from the view point of piping design. Through the past experiences and developments of the fabrication, inspection, and operation of nuclear power plants, it has been recognized that the Leak-Before-Break (LBB) concept can be justified in the LWR pressure boundary pipings. In order to verify the LBB concept, extensive experimental and theoretical works are being conducted in many countries. Furthermore, a revised piping design standard, in which LBB concept is introduced, is under preparation in Japan, U.S.A., and European countries. At JAERI, a research program to investigate the unstable ductile fracture behavior of LWR piping under bending load has been carried out as a part of the LBB verification researches since 1983. This report summarizes the result of the ductile fracture tests conducted at room temperature in 1983 and 84. The 6-inch diameter pipes of type 304 stainless steel and STS 42 carbon steel pipe with a through-wall or part-through crack were tested under bending load with low or high compliance condition at room temperature. Pipe fracture data were obtained from the test as regards to load- displacement curve, crack extension, net section stress, J-resistance curve, and so on. Besides, the influence of the compliance on the fracture behavior was examined. Discussions are performed on the ductile pipe fracture criterion, flaw evaluation criterion, and LBB evaluation method. (author)

  11. Neratinib: Inching up on the cure rate of HER2+ breast cancer?

    Science.gov (United States)

    Unni, Nisha; Sudhan, Dhivya R; Arteaga, Carlos L

    2018-05-25

    Neratinib was recently approved by FDA for extended adjuvant treatment of HER-2 positive breast cancer. ExteNET trial showed improvement in invasive disease-free survival (iDFS) in the neratinib arm compared to placebo. The benefit was more pronounced in patients with ER+/HER2+ tumors, suggesting bidirectional crosstalk between the two pathways. Copyright ©2018, American Association for Cancer Research.

  12. Effect of logging wounds on diameter growth of sawlog-size Appalachian hardwood crop trees

    Science.gov (United States)

    Neil I. Lamson; H. Clay Smith; H. Clay Smith

    1988-01-01

    In previously thinned, even-aged Appalachian hardwood stands, 5-year diameter growth of 102 wounded and 102 unwounded codominant crop trees were compared. A wounded crop tre was defined as one with at least one exposed sapwood logging wound at least 100 inch2 in size. An unwounded crop tree of the same species and size was selected near each of the 102 wounded trees....

  13. Numerical Investigation of Liquid Carryover in T-Junction with Different Diameter Ratios

    Science.gov (United States)

    Pao, William; Sam, Ban; Saieed, Ahmed; Tran, Cong Minh

    2018-03-01

    In offshore Malaysia, T-junction is installed at the production header as a compact separator to tap produced gas from reservoir as fuel gas for power generation. However, excessive liquid carryover in T-junction presents a serious operational issue because it trips the whole production platform. The primary objective of present study is to numerically investigate the liquid carryover due to formation of slug, subsequently its liquid carryover at different diameter ratio. The analyses were carried out on a model with 0.0254 m (1 inch) diameter horizontal main arm and a vertically upward side arm using Volume of Fluid Method. Three different sides to main arm diameter ratio of 1.0, 0.5 and 0.3 were investigated with different gas and liquid superficial velocities. The results showed that, while the general trend is true that smaller diameter ratio T-junction has lesser liquid take off capacity, it has a very high frequency of low liquid carryover threshold. In other words, under slug flow, smaller diameter ratio T-junction is constantly transporting liquid even though at a lesser volume in comparison to regular T-junction.

  14. TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

    International Nuclear Information System (INIS)

    Hernandez, A; Gazi, P; Seibert, J; Boone, J

    2015-01-01

    Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R 2 ) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R 2 values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image

  15. TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A; Gazi, P [Biomedical Engineering Graduate Group, University of California Davis, Davis, CA (United States); Department of Radiology, UC Davis Medical Center, Sacramento, CA (United States); Seibert, J; Boone, J [Department of Radiology, UC Davis Medical Center, Sacramento, CA (United States); Department of Biomedical Engineering, University of California Davis, Davis, CA (United States)

    2015-06-15

    Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R{sup 2}) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R{sup 2} values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image.

  16. Development of 52 inches last stage blade for steam turbines

    International Nuclear Information System (INIS)

    Suzuki, Atsuhide; Hisa, Shoichi; Nagao, Shinichiro; Ogata, Hisao

    1986-01-01

    The last stage blades of steam turbines are the important component controlling the power output and performance of plants. In order to realize a unit of large capacity and high efficiency, the proper exhaust area and the last stage blades having good performance are indispensable. Toshiba Corp. has completed the development of the 52 inch last stage blades for 1500 and 1800 rpm steam turbines. The 52 inch last stage blades are the longest in the world, which have the annular exhaust area nearly 1.5 times as much as that of 41 inch blades used for 1100 MW, 1500 rpm turbines in nuclear power stations. By adopting these 52 inch blades, the large capacity nuclear power plants up to 1800 MW can be economically constructed, the rate of heat consumption of 1350 MW plants is improved by 3 ∼ 4 % as compared with 41 inch blades, and in the plants up to 1100 MW, LP turbines can be reduced from three sets to two. The features of 52 inch blades, the flow pattern and blade form design, the structural strength analysis and the erosion withstanding property, and the verification by the rotation test of the actual blades, the performance test using a test turbine, the vibration analysis of the actually loaded blades and the analysis of wet steam behavior are reported. (Kako, I.)

  17. A novel 2D silicon nano-mold fabrication technique for linear nanochannels over a 4 inch diameter substrate

    Science.gov (United States)

    Yin, Zhifu; Qi, Liping; Zou, Helin; Sun, Lei

    2016-01-01

    A novel low-cost 2D silicon nano-mold fabrication technique was developed based on Cu inclined-deposition and Ar+ (argon ion) etching. With this technique, sub-100 nm 2D (two dimensional) nano-channels can be etched economically over the whole area of a 4 inch n-type  silicon wafer. The fabricating process consists of only 4 steps, UV (Ultraviolet) lithography, inclined Cu deposition, Ar+ sputter etching, and photoresist & Cu removing. During this nano-mold fabrication process, we investigated the influence of the deposition angle on the width of the nano-channels and the effect of Ar+ etching time on their depth. Post-etching measurements showed the accuracy of the nanochannels over the whole area: the variation in width is 10%, in depth it is 11%. However, post-etching measurements also showed the accuracy of the nanochannels between chips: the variation in width is 2%, in depth it is 5%. With this newly developed technology, low-cost and large scale 2D nano-molds can be fabricated, which allows commercial manufacturing of nano-components over large areas. PMID:26752559

  18. Risk assessment of K Basin twelve-inch and four-inch drain valve failure from a postulated seismic initiating event

    Energy Technology Data Exchange (ETDEWEB)

    MORGAN, R.G.

    1999-06-23

    The Spent Nuclear Fuel (SNF) Project will transfer metallic SNF from the Hanford 105 K-East and 105 K-West Basins to safe interim storage in the Canister Storage Building in the 200 Area. The initial basis for design, fabrication, installation, and operation of the fuel removal systems was that the basin leak rate which could result from a postulated accident condition would not be excessive relative to reasonable recovery operations. However, an additional potential K Basin water leak path is through the K Basin drain valves. Three twelve-inch drain valves are located in the main basin bays along the north wall. Five four-inch drain valves are located in the north and south loadout pits (NLOP and SLOP), the weasel pit, the technical viewing pit, and the discharge chute pit. The sumps containing the valves are filled with concrete which covers the drain valve body. Visual observations indicate that only the valve's bonnet and stem are exposed above the basin concrete floor for the twelve-inch drain valve and that much less of the valve's bonnet and stem are exposed above the basin concrete floor for the five four-inch drain valves. It was recognized, however, that damage of the drain valve bonnet or stem during a seismic initiating event could provide a potential K Basin water leak path. The objectives of this analysis are to: (1) evaluate the likelihood of damaging the three twelve-inch drain valves located along the north wall of the main basin and the five four-inch drain valves located in the pits from a seismic initiating event, and (2) determine the likelihood of exceeding a specific consequence (initial leak rate) from a damaged valve. The analysis process is a risk-based uncertainty analysis where each variable is modeled using available information and engineering judgement. The uncertainty associated with each variable is represented by a probability distribution (probability density function). Uncertainty exists because of the inherent

  19. The influence of patient positioning in breast CT on breast tissue coverage and patient comfort

    Energy Technology Data Exchange (ETDEWEB)

    Roessler, A.C.; Althoff, F.; Kalender, W. [Erlangen Univ. (Germany). Inst. of Medical Physics; Wenkel, E. [University Hospital of Erlangen (Germany). Radiological Inst.

    2015-02-15

    The presented study aimed at optimizing a patient table design for breast CT (BCT) systems with respect to breast tissue coverage and patient comfort. Additionally, the benefits and acceptance of an immobilization device for BCT using underpressure were evaluated. Three different study parts were carried out. In a positioning study women were investigated on an MRI tabletop with exchangeable inserts (flat and cone-shaped with different opening diameters) to evaluate their influence on breast coverage and patient comfort in various positioning alternatives. Breast length and volume were calculated to compare positioning modalities including various opening diameters and forms. In the second study part, an underpressure system was tested for its functionality and comfort on a stereotactic biopsy table mimicking a future CT scanner table. In the last study part, this system was tested regarding breast tissue coverage. Best results for breast tissue coverage were shown for cone-shaped table inserts with an opening of 180 mm. Flat inserts did not provide complete coverage of breast tissue. The underpressure system showed robust function and tended to pull more breast tissue into the field of view. Patient comfort was rated good for all table inserts, with highest ratings for cone-shaped inserts. Cone-shaped tabletops appeared to be adequate for BCT systems and to allow imaging of almost the complete breast. An underpressure system proved promising for the fixation of the breast during imaging and increased coverage. Patient comfort appears to be adequate.

  20. Study on water leak-tightness of small leaks on a 1 inch cylinder valve

    International Nuclear Information System (INIS)

    Miyazawa, T.; Kasai, Y.; Inabe, N.; Aritomi, M.

    2002-01-01

    Practical thresholds for water leak-tightness of small leaks were determined by experimentation. Measurements for small leak samples were taken of air leakage rates and water leakage rates for identical leak samples in order to identify parameters that influence water leak-tightness threshold. Four types of leaks were evaluated: a fine wire inserted in an O-ring seal, a glass capillary tube, a stainless steel orifice, and a scratched valve stem on a 1 inch UF 6 cylinder valve. Experimental results demonstrated that the key parameter for water leak-tightness is the opening size of the leak hole. The maximum allowable hole size to achieve water leak-tightness ranged from 10 to 20 μm in diameter in this study. Experimental results with 1 inch UF 6 cylinder valve samples demonstrated that the acceptance criteria for preshipment leakage test, 1x10 -3 ref-cm 3 .s -1 , as prescribed in ANSI N14.5 is an appropriate value from the point of view of water leak-tightness for enriched UF 6 packages. The mechanism of water leak-tightness is plugging by tiny particles existing in water. The water used in experiments in this study contained far fewer particles than in water assumed to be encountered under accident conditions of transport. Therefore, the water leak-tightness threshold determined in this study is a conservative value in a practical evaluation. (author)

  1. Adaptability of black walnut, black cherry, and Northern red oak to Northern California

    Science.gov (United States)

    Philip M. McDonald

    1987-01-01

    When planted in sheltered sites in northern California, only 49% of black walnut (Juglans nigra L.) and 58% of black cherry (Prunus serotina Ehrh.) survived for 15 years, and 20% of northern red oak (Quercus rubra L.) survived for 10 years. The black walnut trees averaged 0.6 inches diameter at breast...

  2. Individual tree diameter, height, and volume functions for longleaf pine

    Science.gov (United States)

    Carlos A. Gonzalez-Benecke; Salvador A. Gezan; Timothy A. Martin; Wendell P. Cropper; Lisa J. Samuelson; Daniel J. Leduc

    2014-01-01

    Currently, little information is available to estimate individual tree attributes for longleaf pine (Pinus palustris Mill.), an important tree species of the southeastern United States. The majority of available models are local, relying on stem diameter outside bark at breast height (dbh, cm) and not including stand-level parameters. We developed...

  3. A semi-empirical model for predicting crown diameter of cedrela ...

    African Journals Online (AJOL)

    A semi-empirical model relating age and breast height has been developed to predict individual tree crown diameter for Cedrela odorata (L) plantation in the moist evergreen forest zones of Ghana. The model was based on field records of 269 trees, and could determine the crown cover dynamics, forecast time of canopy ...

  4. Regional Models of Diameter as a Function of Individual Tree Attributes, Climate and Site Characteristics for Six Major Tree Species in Alberta, Canada

    Directory of Open Access Journals (Sweden)

    Dan A. MacIsaac

    2011-09-01

    Full Text Available We investigated the relationship of stem diameter to tree, site and stand characteristics for six major tree species (trembling aspen, white birch, balsam fir, lodgepole pine, black spruce, and white spruce in Alberta (Canada with data from Alberta Sustainable Resource Development Permanent Sample Plots. Using non-linear mixed effects modeling techniques, we developed models to estimate diameter at breast height using height, crown and stand attributes. Mixed effects models (with plot as subject using height, crown area, and basal area of the larger trees explained on average 95% of the variation in diameter at breast height across the six species with a root mean square error of 2.0 cm (13.4% of mean diameter. Fixed effects models (without plot as subject including the Natural Sub-Region (NSR information explained on average 90% of the variation in diameter at breast height across the six species with a root mean square error equal to 2.8 cm (17.9% of mean diameter. Selected climate variables provided similar results to models with NSR information. The inclusion of nutrient regime and moisture regime did not significantly improve the predictive ability of these models.

  5. Pile load test on large diameter steel pipe piles in Timan-Pechora, Russia

    Energy Technology Data Exchange (ETDEWEB)

    McKeown, S. [Golder Associates Inc., Houston, TX (United States); Tart, B. [Golder Associates Inc., Anchorage, AK (United States); Swartz, R. [Paragon Engineering Services Inc., Houston, TX (United States)

    1994-12-31

    Pile load testing conducted in May and June of 1993 at the Polar Lights Ardalin project in Arkangelsk province, Russia, was documented. Pile load testing was conducted to determine the ultimate and allowable pile loads for varying pile lengths and ground temperature conditions and to provide creep test data for deformation under constant load. The piles consisted of 20 inch diameter steel pipe piles driven open ended through prebored holes into the permafrost soils. Ultimate pile capacities, adfreeze bond, and creep properties observed were discussed. 10 figs., 4 tabs.

  6. Celiac Disease: Four Inches and Seven Pounds...

    Science.gov (United States)

    ... Disease" Articles Celiac Disease Changes Everything / What is Celiac Disease? / Symptoms, Diagnosis & Treatment / Four Inches and Seven Pounds… / Learning to Live Well with Celiac Disease / Living Gluten-Free Spring 2015 Issue: Volume 10 ...

  7. Evaluation of a cut-to-length system implementing fuel reduction treatments on the Coconino National Forest in Arizona

    Science.gov (United States)

    John Klepac; Bob Rummer; Jason Thompson

    2006-01-01

    A Cut-to-Length (CTL) system was evaluated for production and cost while implementing fuel reduction treatments in two stands on the Coconino National Forest in Arizona. Product recovery and fire behavior within each stand after treatment were also examined. Only trees less than 16 inches diameter breast height (DBH) were harvested. After logs were forwarded to a...

  8. PROFIT-PC: a program for estimating maximum net revenue from multiproduct harvests in Appalachian hardwoods

    Science.gov (United States)

    Chris B. LeDoux; John E. Baumgras; R. Bryan Selbe

    1989-01-01

    PROFIT-PC is a menu driven, interactive PC (personal computer) program that estimates optimum product mix and maximum net harvesting revenue based on projected product yields and stump-to-mill timber harvesting costs. Required inputs include the number of trees/acre by species and 2 inches diameter at breast-height class, delivered product prices by species and product...

  9. Equations for predicting diameter, height, crown width, and leaf area of San Joaquin Valley street trees

    Science.gov (United States)

    P.J. Peper; E.G. McPherson; S.M. Mori

    2001-01-01

    Although the modeling of energy-use reduction, air pollution uptake, rainfall interception, and microclimate modification associated with urban trees depends on data relating diameter at breast height (dbh) , crown height, crown diameter, and leaf area to tree age or dbh, scant information is available for common municipal tree species . I n this study , tree height ,...

  10. Real-time precision measuring device of tree diameter growth

    Science.gov (United States)

    Guo, Mingming; Chen, Aijun; Li, Dongsheng; Liu, Nan; Yao, Jingyuan

    2016-01-01

    DBH(diameter at breast height) is an important factor to reflect of the quality of plant growth, also an important parameter indispensable in forest resources inventory and forest carbon sink, the accurate measurement of DBH or not is directly related to the research of forest resources inventory and forest carbon sink. In this paper, the principle and the mathematical model of DBH measurement device were introduced, the fixture measuring device and the hardware circuit for this tree diameter were designed, the measurement software programs were compiled, and the precision measuring device of tree diameter growth was developed. Some experiments with Australia fir were conducted. Based on experiment data, the correlations among the DBH variation of Australian fir, the environment temperature, air humility and PAR(photosynthetically active radiation) were obtained. The effects of environmental parameters (environment temperature, air humility and PAR) on tree diameter were analyzed. Experimental results show that there is a positive correlation between DBH variation of Australian fir and environment temperature, a negative correlation between DBH variation of Australian fir and air humility , so is PAR.

  11. Torque expression of 0.018 and 0.022 inch conventional brackets

    NARCIS (Netherlands)

    Sifakakis, I.; Pandis, N.; Makou, M.; Eliades, T.; Katsaros, C.; Bourauel, C.

    2013-01-01

    The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond(R) Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch.

  12. Correlations between some physiographic factors and diameter, height and cone characteristics in stone pine (Pinus pinea L. afforestation areas in Balıkesir-Burhaniye region

    Directory of Open Access Journals (Sweden)

    Ali Ömer Üçler

    2017-11-01

    Full Text Available In this study, effects of some physiographic factors (aspect, slope and elevation on breast diameter, height and cone properties (cone weight, number of cones, cone width and cone length in stone pine (Pinus pinea L. afforestation areas in Balıkesir-Burhaniye region were investigated. To determine to effects of physiographic conditions, study area is separated according to aspect, slope and elevation groups. Aspect is separated two groups which are shady aspect (B1 and sunny aspect (B2. Slope is separated two groups which are small from 36 percent (E1 and big from 36 percent (E2. Elevation also is separated two groups which are under 400 meters (Y1 and over 400 meters (Y2. Sample areas were scattering to land classifications by using Stratified Sampling Method. Thus, each aspect, slope and elevation classifications were obtained from sample area where are provided from 32 different areas. Tree heights, the diameter at breast height and cone number were measured on saplings. In addition, in each sample area five Pinus pinea trees were selected. It was measured cone diameter, cone height and air-dries weight values of cones which are picked from selecting trees. According to statistical analysis results, aspect effects to tree heights, cone number and cone weight; slope effects the diameter at breast height, cone number and cone diameter; elevation effects the diameter at breast height, tree height, cone number and cone weight. In terms of tree height and diameter values; the highest average breast height diameter was found in the B1E1Y1 with 13.6 cm, and the highest average height value was found in the B2E2Y2 by interaction. In terms of cone characteristics; with the highest average cone number of 8.5 in B1E1Y1, the highest mean cone weight in B1E1Y1 with 232 gr and the highest cone diameter in B2E2Y1 with 5.4 cm. According to the results of correlation analysis; it was determined that slope and elevation factors have positive effect on breast

  13. Numerical simulation of two-phase slug flow with liquid carryover in different diameter ratio T-junction

    Science.gov (United States)

    Pao, W.; Hon, L.; Saieed, A.; Ban, S.

    2017-10-01

    A smaller diameter conduit pointing at 12 o’clock position is typically hot-tapped to a horizontal laying production header in offshore platform to tap produced gas for downstream process train. This geometric feature is commonly known as T-junction. The nature of multiphase fluid splitting at the T-junction is a major operational challenge due to unpredictable production environment. Often, excessive liquid carryover occurs in the T-junction, leading to complete platform trip and halt production. This is because the downstream process train is not designed to handle excessive liquid. The objective of this research is to quantify the effect of different diameter ratio on phase separation efficiency in T-junction. The liquid carryover is modelled as two-phase air-water flow using Eulerian Mixture Model coupled with Volume of Fluid Method to mimic the slug flow in the main pipe. The focus in this paper is 0.0254 m (1 inch) diameter horizontal main arm and vertical branch arm with diameter ratio of 1.0, 0.5 and 0.3. The present research narrowed the investigation to only slug flow regime using Baker’s map as reference. The investigation found that, contrary to common believe, smaller diameter ratio T-junction perform worse than larger diameter ratio T-junction.

  14. The urban forests of Philadelphia

    Science.gov (United States)

    David J. Nowak; Allison R. Bodine; Robert Hoehn; Alexis Ellis; Sarah C. Low; Lara A. Roman; Jason G. Henning; Emily Stephan; Tom Taggert; Ted. Endreny

    2016-01-01

    An analysis of the urban forest in Philadelphia, Pennsylvania, reveals that this city has an estimated 2.9 million trees (encompassing all woody plants greater than 1 inch diameter at breast height [d.b.h]) with tree canopy that covers 20 percent of the city. The most common tree species are spicebush, black cherry, ash, tree-of-heaven, and boxelder, but the most...

  15. Analysis of harvesting opportunities for thinning eastern hardwoods on steep terrain

    Science.gov (United States)

    Chris B. LeDoux; John E. Baumgras

    1988-01-01

    Harvesting cost and revenue models were used to evaluate yarding costs by yarder type and to compare stump-to-mill harvesting costs to revenues available from multiproduct thinnings in eastern hardwoods. This analysis includes six types of cable yarders and thinnings in stands where the average diameter at breast height of trees harvested ranged from 7 to 12 inches. To...

  16. Corrosion and deposit determination in large diameter pipes by radiography

    International Nuclear Information System (INIS)

    Harara, W.

    2006-08-01

    Two steel reference pipes with outer diameters of 8 and 12 inches were machined to make artificial defects on each of them, such as inside and outside steps of different wall thicknesses, inside and outside flat bottomed holes (FBH) of different diameters and depths on steps, flat area (FA), and ground patch (GP). The artificial defect were made to simulate natural corrosion attack as regular corrosion and pitting. The two reference pipes were tested according to tangential radiography technique and double wall single image technique. Tangential radiography technique had been applied using Co-60 radio-isotope to determine the steps thicknesses, the FBH, the remaining wall thickness under the FA, the remaining wall thickness above the GP, and the minimum detectable thickness of the artificial cement deposit on the two reference pipes, with and without insulation. Double wall single image technique had also been applied on the two reference pipes with and without insulation using Ir-192 radio-isotope to measure the flat bottomed holes depths, GP depth, and FA depth by density measurement. The measurement results obtained from the radiographs confirm that, tangential radiography technique can be applied to detect and evaluate the inside and outside regular corrosion attack in the large diameter pipes. It can also be applied to detect and evaluate the outside FBH with depth equal or greater than 10%. Inside 10% FBH and inside 20% FBH can not be detected if their diameters are not larger than certain value related to diameter and wall thickness of the pipe under test. Increasing the film density up to 5 outside the pipe did not provide any detection improvement of 10% and 20% inside FBH. Tangential radiography technique can also be applied to detect and measure the deposit inside the pipes. Double wall technique can be applied as an alternative method of the tangential radiography technique to detect and to evaluate the shallow and small diameter, 10% and 20% inside FBH

  17. Relationships between stem diameter at breast height (DBH), tree ...

    African Journals Online (AJOL)

    buba

    amount of light that the tree intercepts for photosynthesis. The tree stem size has its ... the amount of solar radiation intercepted by a tree. (Tanka, 2006). .... 7. Stem Diameter. C ro w n le n g th. Figure 2. Graph of the relationship between stem dbh vs. crown crown length. 0.7. 0.6. 0.5. 0.4. 0.3. 15. 14. 13. 12. 11. 10. 9. 8. 7. 6. 5.

  18. Distance-independent individual tree diameter-increment model for Thuya [Tetraclinis articulata (VAHL.) MAST.] stands in Tunisia

    OpenAIRE

    T. Sghaier; M. Tome; J. Tome; M. Sanchez-Gonzalez; I. Cañellas; R. Calama

    2013-01-01

    Aim of study: The aim of the work was to develop an individual tree diameter-increment model for Thuya (Tetraclinis articulata) in Tunisia.Area of study: The natural Tetraclinis articulata stands at Jbel Lattrech in north-eastern of Tunisia.Material and methods:  Data came from 200 trees located in 50 sample plots. The diameter at age t and the diameter increment for the last five years obtained from cores taken at breast height were measured for each tree. Four difference equations derived f...

  19. Image and pathological changes after microwave ablation of breast cancer: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Wenbin [Department of Breast Surgery, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China); Jiang, Yanni [Department of Radiology, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China); Chen, Lin; Ling, Lijun; Liang, Mengdi; Pan, Hong [Department of Breast Surgery, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China); Wang, Siqi [Department of Radiology, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China); Ding, Qiang [Department of Breast Surgery, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China); Liu, Xiaoan, E-mail: liuxiaoan@126.com [Department of Breast Surgery, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China); Wang, Shui, E-mail: ws0801@hotmail.com [Department of Breast Surgery, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China)

    2014-10-15

    Highlights: • We report successful experience of MWA in breast cancer under local anesthesia. • We report MR imaging evaluation of microwave ablation zone in breast cancer. • Pathological changes after microwave ablation in breast cancer was reported. • 2 min MWA caused an ablation zone with three diameters > 2 cm in breast cancer. - Abstract: Purpose: To prospectively assess MR imaging evaluation of the ablation zone and pathological changes after microwave ablation (MWA) in breast cancer. Materials and methods: Twelve enrolled patients, diagnosed with non-operable locally advanced breast cancer (LABC), were treated by MWA and then neoadjuvant chemotherapy, followed by surgery. MR imaging was applied to evaluate the effect of MWA. Hematoxylin-eosin (HE) staining and transmission electron microscopy (TEM) were applied to analyze the ablated area. Results: All MWA procedures were performed successfully under local anesthesia. For a mean duration of 2.15 min, the mean largest, middle and smallest diameters in the ablated zone 24-h post-ablation in MR imaging were 2.98 cm ± 0.53, 2.51 cm ± 0.41 and 2.23 cm ± 0.41, respectively. The general shape of the ablation zone was close to a sphere. The ablated area became gradually smaller in MR imaging. No adverse effects related to MWA were noted in all 12 patients during and after MWA. HE staining could confirm the effect about 3 months after MWA, which was confirmed by TEM. Conclusions: 2 min MWA can cause an ablation zone with three diameters larger than 2 cm in breast cancer, which may be suitable for the local treatment of breast cancer up to 2 cm in largest diameter. However, the long-term effect of MWA in the treatment of small breast cancer should be determined in the future.

  20. CT measurement of breast glandular tissue and its association with testicular cancer

    Energy Technology Data Exchange (ETDEWEB)

    Klang, Eyal [Tel Aviv University, Department of Radiology, Chaim Sheba Medical Center, Tel Aviv (Israel); The Chaim Sheba Medical Center, Tel Hashomer (Israel); Rozendorn, Noa; Raskin, Steve; Portnoy, Orith; Sklair, Miri; Marom, Edith M.; Konen, Eli; Amitai, Michal M. [Tel Aviv University, Department of Radiology, Chaim Sheba Medical Center, Tel Aviv (Israel)

    2017-02-15

    To evaluate the associations between breast glandular tissues diameters as determined by CT and b-hCG levels, histological types, tumour spread and prognosis in patients with testicular germ cell tumour. Ninety-four patients with pre-treatment CT scan and markers (b-hCG, AFP, LDH) were retrospectively collected. A radiologist measured diameters in all CT examinations and correlation between diameters and log (b-hCG) was assessed (Pearson's coefficient). The ability of measured diameters to predict lymphatic and distant haematogenous metastatic spread was evaluated (ROC curves). The associations between measured diameter cut-off values of 20 and 25 mm and International Germ Cell Cancer Collaborative Group (IGCCCG) classification, lymphatic and distant haematogenous metastatic spread and histological subtypes were evaluated (chi squared test). Breast glandular diameters correlated to log(b-hCG) (r = 0.579) and predicted distant haematogenous metastatic spread (AUC = 0.78). Worse prognosis (intermediate or poor IGCCCG) was shown for 20 mm (27.3 vs. 4.2 %, p = 0.005) and 25 mm (33.3 vs. 6.1 %, p = 0.014). A diameter of 25 mm was associated with non-seminoma (91.7 vs. 48.8 %, p = 0.005). Breast glandular tissue diameters correlated with log(b-hCG) and predicted distant haematogenous metastases. Twenty and 25 mm were associated with worse prognosis and 25 mm was able to distinguish between seminoma and non-seminoma. (orig.)

  1. Growth and yield of a managed 30-year-old noble fir plantation.

    Science.gov (United States)

    Marshall D. Murray

    1988-01-01

    A thinned and fertilized noble fir plantation produced 3,450 cubic feet per acre 30 years after it was planted in western Washington. More than half of this volume was in trees with diameter at breast height of 10 inches and larger. Current annual increment the last 6 years was 295 cubic feet per acre. Ornamental boughs have been harvested annually for about a 15-year...

  2. Validation and Application of Computed Radiography (CR) Tangential Technique for Wall Thickness Measurement of 10 Inch Carbon Steel Pipe

    International Nuclear Information System (INIS)

    Norhazleena Azaman; Khairul Anuar Mohd Salleh; Amry Amin Abas; Arshad Yassin; Sukhri Ahmad

    2016-01-01

    Oil and gas industry requires Non Destructive Testing (NDT) to ensure each components, in-service and critical, are fit-for-purpose. Pipes that are used to transfer oil or gas are amongst the critical component that needs to be well maintained and inspected. Typical pipe discontinuities that may lead to unintended incidents are erosion, corrosion, dent, welding defects, etc. Wall thickness assessment, with Radiography Testing (RT) is normally used to inspect such discontinuities and can be performed with two approaches; (a) center line beam tangential technique (b) offset from the centre pipe tangential technique. The latter is a method of choice for this work because of the pipe dimension and limited radiation safe distance at site. Two successful validation approaches (simulation and experimental) were performed to determine the probability of successfulness before the actual RT work with tangential technique is carried out. The pipe was a 10 inch diameter in-service wrapped carbon steel. A 9 Ci Ir-192 and white Imaging Plate (IP) were used as a gamma radiation source and to record the radiographic image. Result of this work suggest that RT with tangential technique for 10 inch wrapped in-service carbon steel pipe can be successfully performed. (author)

  3. Buckling Test Results and Preliminary Test and Analysis Correlation from the 8-Foot-Diameter Orthogrid-Stiffened Cylinder Test Article TA02

    Science.gov (United States)

    Hilburger, Mark W.; Waters, W. Allen, Jr.; Haynie, Waddy T.; Thornburgh, Robert P

    2017-01-01

    Results from the testing of cylinder test article SBKF-P2-CYL-TA02 (referred to herein as TA02) are presented. TA02 is an 8-foot-diameter (96-inches), 78.0-inch-long, aluminum-lithium (Al-Li), orthogrid-stiffened cylindrical shell similar to those used in current state-of-the-art launch-vehicle structures and was designed to exhibit global buckling when subjected to combined compression and bending loads. The testing was conducted at the Marshall Space Flight Center (MSFC), February 3-6, 2009, in support of the Shell Buckling Knockdown Factor Project (SBKF). The test was used to verify the performance of a newly constructed buckling test facility at MSFC and to verify the test article design and analysis approach used by the SBKF researchers.

  4. Aero-acoustic design and test of a multiple splitter exhaust noise suppressor for a 0.914m diameter lift fan

    Science.gov (United States)

    Stimpert, D. L.

    1973-01-01

    A lift fan exhaust suppression system to meet future VTOL aircraft noise goals was designed and tested. The test vehicle was a 1.3 pressure ratio, 36 inch (91.44 cm) diameter lift fan with two chord rotor to stator spacing. A two splitter fan exhaust suppression system thirty inches (76.2 cm) long achieved 10 PNdB exhaust suppression in the aft quadrant compared to a design value of 20 PNdB. It was found that a broadband noise floor limited the realizable suppression. An analytical investigation of broadband noise generated by flow over the treatment surfaces provided very good agreement with the measured suppression levels and noise floor sound power levels. A fan thrust decrement of 22% was measured for the fully suppressed configuration of which 11.1% was attributed to the exhaust suppression hardware.

  5. Modeling Caribbean tree stem diameters from tree height and crown width measurements

    Science.gov (United States)

    Thomas Brandeis; KaDonna Randolph; Mike Strub

    2009-01-01

    Regression models to predict diameter at breast height (DBH) as a function of tree height and maximum crown radius were developed for Caribbean forests based on data collected by the U.S. Forest Service in the Commonwealth of Puerto Rico and Territory of the U.S. Virgin Islands. The model predicting DBH from tree height fit reasonably well (R2 = 0.7110), with...

  6. Progress in Electron Beam Mastering of 100 Gbit/inch2 Density Disc

    Science.gov (United States)

    Takeda, Minoru; Furuki, Motohiro; Yamamoto, Masanobu; Shinoda, Masataka; Saito, Kimihiro; Aki, Yuichi; Kawase, Hiroshi; Koizumi, Mitsuru; Miyokawa, Toshiaki; Mutou, Masao; Handa, Nobuo

    2004-07-01

    We developed an electron beam recorder (EBR) capable of recording master discs under atmospheric conditions using a novel differential pumping head. Using the EBR and optimized fabrication process for Si-etched discs with reactive ion etching (RIE), a bottom signal jitter of 9.6% was obtained from a 36 Gbit/inch2 density disc, readout using a near-field optical pickup with an effective numerical aperture (NA) of 1.85 and a wavelength of 405 nm. We also obtained the eye patterns from a 70 Gbit/inch2 density disc readout using an optical pickup with a 2.05 NA and the same wavelength, and showed almost the same modulation ratio as the simulation value. Moreover, the capability of producing pit patterns corresponding to a 104 Gbit/inch2 density is demonstrated.

  7. Reducing radiation dose to the female breast during conventional and dedicated breast computed tomography

    Science.gov (United States)

    Rupcich, Franco John

    The purpose of this study was to quantify the effectiveness of techniques intended to reduce dose to the breast during CT coronary angiography (CTCA) scans with respect to task-based image quality, and to evaluate the effectiveness of optimal energy weighting in improving contrast-to-noise ratio (CNR), and thus the potential for reducing breast dose, during energy-resolved dedicated breast CT. A database quantifying organ dose for several radiosensitive organs irradiated during CTCA, including the breast, was generated using Monte Carlo simulations. This database facilitates estimation of organ-specific dose deposited during CTCA protocols using arbitrary x-ray spectra or tube-current modulation schemes without the need to run Monte Carlo simulations. The database was used to estimate breast dose for simulated CT images acquired for a reference protocol and five protocols intended to reduce breast dose. For each protocol, the performance of two tasks (detection of signals with unknown locations) was compared over a range of breast dose levels using a task-based, signal-detectability metric: the estimator of the area under the exponential free-response relative operating characteristic curve, AFE. For large-diameter/medium-contrast signals, when maintaining equivalent AFE, the 80 kV partial, 80 kV, 120 kV partial, and 120 kV tube-current modulated protocols reduced breast dose by 85%, 81%, 18%, and 6%, respectively, while the shielded protocol increased breast dose by 68%. Results for the small-diameter/high-contrast signal followed similar trends, but with smaller magnitude of the percent changes in dose. The 80 kV protocols demonstrated the greatest reduction to breast dose, however, the subsequent increase in noise may be clinically unacceptable. Tube output for these protocols can be adjusted to achieve more desirable noise levels with lesser dose reduction. The improvement in CNR of optimally projection-based and image-based weighted images relative to photon

  8. Microcalcification detectability using a bench-top prototype photon-counting breast CT based on a Si strip detector.

    Science.gov (United States)

    Cho, Hyo-Min; Ding, Huanjun; Barber, William C; Iwanczyk, Jan S; Molloi, Sabee

    2015-07-01

    To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on energy-resolved photon-counting silicon (Si) strip detectors. The proposed photon-counting breast CT system and a bench-top prototype photon-counting breast CT system were simulated using a simulation package written in matlab to determine the smallest detectable μCa. A 14 cm diameter cylindrical phantom made of breast tissue with 20% glandularity was used to simulate an average-sized breast. Five different size groups of calcium carbonate grains, from 100 to 180 μm in diameter, were simulated inside of the cylindrical phantom. The images were acquired with a mean glandular dose (MGD) in the range of 0.7-8 mGy. A total of 400 images was used to perform a reader study. Another simulation study was performed using a 1.6 cm diameter cylindrical phantom to validate the experimental results from a bench-top prototype breast CT system. In the experimental study, a bench-top prototype CT system was constructed using a tungsten anode x-ray source and a single line 256-pixels Si strip photon-counting detector with a pixel pitch of 100 μm. Calcium carbonate grains, with diameter in the range of 105-215 μm, were embedded in a cylindrical plastic resin phantom to simulate μCas. The physical phantoms were imaged at 65 kVp with an entrance exposure in the range of 0.6-8 mGy. A total of 500 images was used to perform another reader study. The images were displayed in random order to three blinded observers, who were asked to give a 4-point confidence rating on each image regarding the presence of μCa. The μCa detectability for each image was evaluated by using the average area under the receiver operating characteristic curve (AUC) across the readers. The simulation results using a 14 cm diameter breast phantom showed that the proposed photon-counting breast CT system can achieve high detection accuracy with an average AUC greater

  9. Quantitative ultrasound characterization of locally advanced breast cancer by estimation of its scatterer properties

    Energy Technology Data Exchange (ETDEWEB)

    Tadayyon, Hadi [Physical Sciences, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Medical Biophysics, Faculty of Medicine, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Sadeghi-Naini, Ali; Czarnota, Gregory, E-mail: Gregory.Czarnota@sunnybrook.ca [Physical Sciences, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Medical Biophysics, Faculty of Medicine, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Radiation Oncology, Faculty of Medicine, University of Toronto, Toronto, Ontario M5T 1P5 (Canada); Wirtzfeld, Lauren [Department of Physics, Ryerson University, Toronto, Ontario M5B 2K3 (Canada); Wright, Frances C. [Division of Surgical Oncology, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada)

    2014-01-15

    Purpose: Tumor grading is an important part of breast cancer diagnosis and currently requires biopsy as its standard. Here, the authors investigate quantitative ultrasound parameters in locally advanced breast cancers that can potentially separate tumors from normal breast tissue and differentiate tumor grades. Methods: Ultrasound images and radiofrequency data from 42 locally advanced breast cancer patients were acquired and analyzed. Parameters related to the linear regression of the power spectrum—midband fit, slope, and 0-MHz-intercept—were determined from breast tumors and normal breast tissues. Mean scatterer spacing was estimated from the spectral autocorrelation, and the effective scatterer diameter and effective acoustic concentration were estimated from the Gaussian form factor. Parametric maps of each quantitative ultrasound parameter were constructed from the gated radiofrequency segments in tumor and normal tissue regions of interest. In addition to the mean values of the parametric maps, higher order statistical features, computed from gray-level co-occurrence matrices were also determined and used for characterization. Finally, linear and quadratic discriminant analyses were performed using combinations of quantitative ultrasound parameters to classify breast tissues. Results: Quantitative ultrasound parameters were found to be statistically different between tumor and normal tissue (p < 0.05). The combination of effective acoustic concentration and mean scatterer spacing could separate tumor from normal tissue with 82% accuracy, while the addition of effective scatterer diameter to the combination did not provide significant improvement (83% accuracy). Furthermore, the two advanced parameters, including effective scatterer diameter and mean scatterer spacing, were found to be statistically differentiating among grade I, II, and III tumors (p = 0.014 for scatterer spacing, p = 0.035 for effective scatterer diameter). The separation of the tumor

  10. Quantitative ultrasound characterization of locally advanced breast cancer by estimation of its scatterer properties

    International Nuclear Information System (INIS)

    Tadayyon, Hadi; Sadeghi-Naini, Ali; Czarnota, Gregory; Wirtzfeld, Lauren; Wright, Frances C.

    2014-01-01

    Purpose: Tumor grading is an important part of breast cancer diagnosis and currently requires biopsy as its standard. Here, the authors investigate quantitative ultrasound parameters in locally advanced breast cancers that can potentially separate tumors from normal breast tissue and differentiate tumor grades. Methods: Ultrasound images and radiofrequency data from 42 locally advanced breast cancer patients were acquired and analyzed. Parameters related to the linear regression of the power spectrum—midband fit, slope, and 0-MHz-intercept—were determined from breast tumors and normal breast tissues. Mean scatterer spacing was estimated from the spectral autocorrelation, and the effective scatterer diameter and effective acoustic concentration were estimated from the Gaussian form factor. Parametric maps of each quantitative ultrasound parameter were constructed from the gated radiofrequency segments in tumor and normal tissue regions of interest. In addition to the mean values of the parametric maps, higher order statistical features, computed from gray-level co-occurrence matrices were also determined and used for characterization. Finally, linear and quadratic discriminant analyses were performed using combinations of quantitative ultrasound parameters to classify breast tissues. Results: Quantitative ultrasound parameters were found to be statistically different between tumor and normal tissue (p < 0.05). The combination of effective acoustic concentration and mean scatterer spacing could separate tumor from normal tissue with 82% accuracy, while the addition of effective scatterer diameter to the combination did not provide significant improvement (83% accuracy). Furthermore, the two advanced parameters, including effective scatterer diameter and mean scatterer spacing, were found to be statistically differentiating among grade I, II, and III tumors (p = 0.014 for scatterer spacing, p = 0.035 for effective scatterer diameter). The separation of the tumor

  11. Development of laser cladding system to repair wall thinning of 1-inch heat exchanger tube

    International Nuclear Information System (INIS)

    Terada, Takaya

    2013-01-01

    We developed a laser cladding system to repair the inner wall wastage of heat exchanger tubes. Our system, which is designed to repair thinning tube walls within 100 mm from the edge of a heat exchanger tube, consists of a fiber laser, a composite-type optical fiberscope, a coupling device, a laser processing head, and a wire-feeding device. All of these components were reconfigured from the technologies of FBR maintenance. The laser processing head, which has a 15-mm outer diameter, was designed to be inserted into a 1-inch heat exchanger tube. We mounted a heatproof broadband mirror for laser cladding and fiberscope observation with visible light inside the laser processing head. The wire-feeding device continuously supplied 0.4-mm wire to the laser irradiation spot with variable feeding speeds from 0.5 to 20 mm/s. We are planning to apply our proposed system to the maintenance of aging industrial plants. (author)

  12. Tannins gravimetric yield condensed in Anadenanthera peregrina bark in different diameter classes

    Directory of Open Access Journals (Sweden)

    Caroline Junqueira Sartori

    2014-06-01

    Full Text Available This work aimed to determine the gravimetric yield of condensed tannins in the Anadenanthera peregrina bark in different diameter classes. Fifty-nine trees samples were collected of Anadenanthera peregrina, at 1.30m of the ground (diameter at breast height - DBH, distributed in seven diameter classes. The barks were dried and crushed in mill of hammer. Composite sample was made to prepare the extract. The extraction was done using water in the ratio 15:1 (v/w, added 3% sodium sulfite (w/w in water-bath at 70°C for 4 hours. The material was filtered using fine cloth strainer and concentrated on a heating plate at approximately 150 g. It was determined the extract mass and removed 10 g for obtaining solids content and 20g for the Stiasny's index. The average values of total solids content, Stiasny's index, condensed tannin content and the compound content non-tannin were 11.34%; 75.79%; 12.76% and 4.07%, respectively. The content of solids, Stiasny's index, compound content non-tannin show significant differences between diameter classes. For the condensed tannins production, the diameter class parameter there was no influence.

  13. Comparison of silicon strip tracker module size using large sensors from 6 inch wafers

    CERN Multimedia

    Honma, Alan

    1999-01-01

    Two large silicon strip sensor made from 6 inch wafers are placed next to each other to simulate the size of a CMS outer silicon tracker module. On the left is a prototype 2 sensor CMS inner endcap silicon tracker module made from 4 inch wafers.

  14. Selection of large diameter drills with the aid of a computer, between diesel and electric alternatives for sedimentary mining. Seleccion de perforadoras de gran diametro con ayuda de ordenador, alternativa diesel electrica en mineria sedimentaria

    Energy Technology Data Exchange (ETDEWEB)

    Colomo Gomez, M. (ENCASUR, Ciudad Real (Spain))

    1988-01-01

    The communication develops a rotary drill rig selection study carried out in Mina Emma, ENCASUR Puertollano (Open pit coal mine), for diameters extended from 9 7/8 to 15 inches and bench heights 10, 15 and 20 meters. Since the choice of diameters is in the transition area from diesel to electric machines, the conclusions are specially interesting in making buying decisions of this kind. 6 figs., 6 tabs.

  15. THE CLINICAL SIGNIFICANCE OF 99mTc-MIBI BREAST IMAGING IN THE DIAGNOSIS OF EARLY BREAST CANCER

    Institute of Scientific and Technical Information of China (English)

    任长才; 金少津; 邹强; 朱汇庆; 王红鹰; 梁春立

    2001-01-01

    Objective: To find an effective, sensitive, specific and noninvasive diagnostic method of breast cancer. Methods: 109 masses of 102 patients with breast lesions smaller than 2 cm in diameter were divided into three groups to undergo 99mTc-MIBI imaging and compared with the results of pathology examination. 20 cases without breast lesions were selected as control. Abnormal condensation of 99mTc-MIBI in the breast reaching 10% higher than that in the counterpart of the healthy breast was regarded as positive. Results: Of 32 breast cancers, positive imaging appeared in 25. Negative imaging were found in 31 of 38 benign breast lesions. Of 39 occult breast lesions, positive imaging appeared in 6 and 3 of them were breast cancer, 2 of 3 patients with slightly increased 99mTc-MIBI imaging threshold were breast cancer also. No positive imaging was found in the control group. The diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value of 99mTc-MIBI was 88.4%, 89.2%, 88.0%, 75.0% and 95.3%, respectively. Conclusion: 99mTc-MIBI imaging had higher sensitivity and accuracy in the diagnosis of breast cancer and differentiation between benign and malignant breast lesions. It could provide useful information for the diagnosis of clinically suspected breast cancer.

  16. Heavy-ion mammography and breast cancer

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Tobias, C.A.; Capp, M.P.; Holley, W.R.; Woodruff, K.H.; Sickles, E.A.

    1980-01-01

    Heavy-ion radiography is a new diagnostic imaging technique developed in our laboratory that produces superior density resolution at low radiation doses. Heavy-ion mammography has now emerged as a low-dose, safe, reliable, noninvasive diagnostic radiological procedure that can quantitate and image very small differences in soft tissue densities in the breast tissues of patients with clinical breast disease. The improved density resolution of heavy-ion mammography over conventional X-ray mammography and breast xerography provides the potential of detecting small breast cancers of less than 1 cm diameter. The radiation dose to the breast from carbon-ion mammorgraphy is about 50 mrad or less, and can potentially be only a fraction of this level. The results of the present clinical trial in progress of heavy-ion mammography in 37 patients, thus far studied, are extremely encouraging, and warrant continued study for application to the early diagnosis of breast cancer in women

  17. Compatible above-ground biomass equations and carbon stock estimation for small diameter Turkish pine (Pinus brutia Ten.).

    Science.gov (United States)

    Sakici, Oytun Emre; Kucuk, Omer; Ashraf, Muhammad Irfan

    2018-04-15

    Small trees and saplings are important for forest management, carbon stock estimation, ecological modeling, and fire management planning. Turkish pine (Pinus brutia Ten.) is a common coniferous species and comprises 25.1% of total forest area of Turkey. Turkish pine is also important due to its flammable fuel characteristics. In this study, compatible above-ground biomass equations were developed to predict needle, branch, stem wood, and above-ground total biomass, and carbon stock assessment was also described for Turkish pine which is smaller than 8 cm diameter at breast height or shorter than breast height. Compatible biomass equations are useful for biomass prediction of small diameter individuals of Turkish pine. These equations will also be helpful in determining fire behavior characteristics and calculating their carbon stock. Overall, present study will be useful for developing ecological models, forest management plans, silvicultural plans, and fire management plans.

  18. Design of Evaporator for Liquid Radioactive Waste Treatment-NPP 1000 MW, PWR

    International Nuclear Information System (INIS)

    Mulyono Daryoko

    2007-01-01

    The evaporator for liquid radioactive waste treatment of 1000 MW NPP-PWR has been designed. The basic calculate of this design was capacity 7000 l/hr, which 5 mg/l solid content. The system used was superheated steam 3.4 atmosphere, 281°F. The data required from design of evaporator are evaporator part (heat exchanger): diameter of shell is 33 inch (82.50 cm), nominal diameter tube is 1.5 inch (3.75 cm), number of tube is 215, tube arrangement triangular pitch is 1 inch pitch, height 600 cm; Mist separator: diameter is 200 inch (500 cm), height 600 inch (1500 cm); Condenser: diameter of shell is 33 inch (82.50 cm), nominal diameter tube is 1.5 inch (3.75 cm), number of tube is 215, tube arrangement triangular pitch is 1 inch pitch, height 600 cm. (author)

  19. Extra-nodal extension is a significant prognostic factor in lymph node positive breast cancer.

    Directory of Open Access Journals (Sweden)

    Sura Aziz

    Full Text Available Presence of lymph node (LN metastasis is a strong prognostic factor in breast cancer, whereas the importance of extra-nodal extension and other nodal tumor features have not yet been fully recognized. Here, we examined microscopic features of lymph node metastases and their prognostic value in a population-based cohort of node positive breast cancer (n = 218, as part of the prospective Norwegian Breast Cancer Screening Program NBCSP (1996-2009. Sections were reviewed for the largest metastatic tumor diameter (TD-MET, nodal afferent and efferent vascular invasion (AVI and EVI, extra-nodal extension (ENE, number of ENE foci, as well as circumferential (CD-ENE and perpendicular (PD-ENE diameter of extra-nodal growth. Number of positive lymph nodes, EVI, and PD-ENE were significantly increased with larger primary tumor (PT diameter. Univariate survival analysis showed that several features of nodal metastases were associated with disease-free (DFS or breast cancer specific survival (BCSS. Multivariate analysis demonstrated an independent prognostic value of PD-ENE (with 3 mm as cut-off value in predicting DFS and BCSS, along with number of positive nodes and histologic grade of the primary tumor (for DFS: P = 0.01, P = 0.02, P = 0.01, respectively; for BCSS: P = 0.02, P = 0.008, P = 0.02, respectively. To conclude, the extent of ENE by its perpendicular diameter was independently prognostic and should be considered in line with nodal tumor burden in treatment decisions of node positive breast cancer.

  20. Simulation of adsorber tube diameter's effect on new design silica gel-water adsorption chiller

    Science.gov (United States)

    Nasruddin, Taufan, A.; Manga, A.; Budiman, D.

    2017-03-01

    A new design of silica gel-water adsorption chiller is proposed. The design configuration is composed of two sorption chambers with compact fin tube heat exchangers as adsorber, condenser, and evaporator. Heat and mass recovery were adopted in order to increase the cooling capacity. Numerical modelling and calculation were used to show the performance of the chiller with different adsorber tube diameter. Under typical condition for hot water inlet/cooling water inlet/chilled water outlet temperatures are 90/30/7°C, respectively, the simulation results showed the best average value of COP, SCP, and cooling power are 0.19, 15.88 W/kg and 279.89 W using 3/8 inch tube.

  1. Cholestrol granuloma of the breast incidentally detected on dynamic abdominal CT: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Sun Hye; Lee, Eun Hye; Hong, Hyun Sook; Kwak, Jeong Ja [Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2016-01-15

    A breast cholesterol granuloma is an uncommon nodular breast lesion. We incidentally detected a persistently enhancing breast mass on the dynamic abdominal computed tomography (CT) of a 78-year-old woman. The mass decreased in diameter over 50 days following a core needle biopsy. This report is the first to describe the dynamic-enhanced CT features of a breast cholesterol granuloma.

  2. Reduction mammaplasty and radiation therapy can allow breast conservation in patients with breast cancers not initially treatable by tumor-ectomy

    International Nuclear Information System (INIS)

    Otmezguine, Y.; Calitchi, E.; Cothier, I.; Feuilhade, F.; Le Bourgeois, J.P.; Baruch, J.

    1997-01-01

    A protocol combining reduction mammaplasty (RM) and radiation therapy was developed as an alternative of mastectomy in patients with breast cancers larger than 3 cm in diameter. This protocol was used in 51 patients between 1983 and 1990. Indications were extensive microcalcifications (n = 17; 33 %) ; residual tumor after neo-adjuvant therapy larger than 4 cm in diameter (n 18 ; 35 %); extensive DCIS (n = 4; 8 %) or tumor located within an area of fibrocystic disease (n = 6; 12 %); presence of a bifocal lesion (n = 12 %. area of fibrocystic disease (n = 6; 12 %); and presence of bifocal lesion (n 6; 12 %). Surgery consisted of tumor-ectomy removing a wide margin of skin and mammary gland, followed by immediate remodeling of the breast, same-side axillary node clearance, and symmetrization of the other breast. A radiation dose of 45 Gy was delivered to the entire mammary gland. Adjuvant therapy was given before and/or after therapy according to the institution's routine breast cancer protocol. During the mean follow-up of 8.1 years, four patients (8 %) developed a local recurrence, which has treated surgically. The five-year disease-free survival rate was 76 %. The cosmetic result was good or very good in 78% of cases. RM plus RT is a reasonable alternative to mastectomy in patients with large breast cancers, although further work is needed to refine its indications. (authors)

  3. Clinical, mammographic, and pathologic concordance in breast cancer

    International Nuclear Information System (INIS)

    Rodriguez Cascaret, Argenis; Martin Rodriguez, Andres; Hernandez Castellanos, Kirenia

    2011-01-01

    An observational descriptive and cross-sectional study was carried out in 100 patients with breast cancer, who attended the Breast Care Department at 'Conrado Benitez' Teaching Oncology Hospital in Santiago de Cuba from August 2009 to July 2010, to characterize them according to imaging, pathological, clinical, and general variables. Percentage as summary measure to statically validate the results and Kappa index to determine diagnostic concordance were used. Women between 40-49 years with history of fibrocystic breast disease and palpable lesions, as well as lump in the right breast, upper outer quadrant and periphery of the breast, tumor greater than one centimeter in diameter and infiltrating ductal carcinoma in the stages III-b and IV prevailed in the case material.(author)

  4. Packing configuration performance for small stem diameters

    International Nuclear Information System (INIS)

    Aikin, J.A.; Spence, C.G.; Cumming, D.

    1997-01-01

    The extensive use of graphite packing and its excellent track record for large isolating valves in CANDU, Primary Heat Transfer (PHT) systems has resulted in an increased application of graphite packing on the conventional side. Many of these applications are in air operated valves (AOVs) where the packing sets are used on small stem diameters (<1 inch) with frequent short-cycling strokes (± 10% of full stroke). The direct application of the proven packing configurations for large isolated valves to control valve application has generated problems such as stiction, packing wear and, in isolated cases, stem stall. To address this issue, a test program was conducted at AECL, CRL by MED branch. The testing showed that by reconfiguring the packing sets and using PTFE wafers reductions in stem friction of 50% at ambient conditions, a 3 fold at hot conditions are achievable. The test program also demonstrated benefits gained in packing wear with different stem roughness finishes and the potential need to exercise small stems valves that see less than full stroke cycling. The paper describes the tests results and provides field support experience. (author)

  5. Normalized glandular dose (DgN) coefficients for flat-panel CT breast imaging

    International Nuclear Information System (INIS)

    Thacker, Samta C; Glick, Stephen J

    2004-01-01

    The development of new digital mammography techniques such as dual-energy imaging, tomosynthesis and CT breast imaging will require investigation of optimal camera design parameters and optimal imaging acquisition parameters. In optimizing these acquisition protocols and imaging systems it is important to have knowledge of the radiation dose to the breast. This study presents a methodology for estimating the normalized glandular dose to the uncompressed breast using the geometry proposed for flat-panel CT breast imaging. The simulation uses the GEANT 3 Monte Carlo code to model x-ray transport and absorption within the breast phantom. The Monte Carlo software was validated for breast dosimetry by comparing results of the normalized glandular dose (DgN) values of the compressed breast to those reported in the literature. The normalized glandular dose was then estimated for a range of breast diameters from 10 cm to 18 cm using an uncompressed breast model with a homogeneous composition of adipose and glandular tissue, and for monoenergetic x-rays from 10 keV to 120 keV. These data were fit providing expressions for the normalized glandular dose. Using these expressions for the DgN coefficients and input variables such as the diameter, height and composition of the breast phantom, the mean glandular dose for any spectra can be estimated. A computer program to provide normalized glandular dose values has been made available online. In addition, figures displaying energy deposition maps are presented to better understand the spatial distribution of dose in CT breast imaging

  6. Test results of a jet impingement from a 4 inch pipe under BWR LOCA conditions

    International Nuclear Information System (INIS)

    Isozaki, Toshikuni; Yano, Toshikazu; Miyazaki, Noriyuki; Kato, Rokuro; Kurihara, Ryoichi; Ueda, Shuzo; Miyazono, Shohachiro

    1982-09-01

    Hypothetical instantaneous pipe rupture is now considered to be one of the design basis accidents during the operation of the light water reactor. If a pipe rupture accidnet occurs, the pipe will start moving with the sudden discharge of internal fluid. So, the various apparatus such as pipe whip restraints and jet deflectors are being installed near the postulated break location to protect the nuclear power plants against the effect of postulated pipe rupture. Pipe whipping test and jet discharge test are now being conducted at the Division of Reactor Safety of the Japan Atomic Energy Research Institute. This report describes the test results of the jet discharge from a 4 inch pipe under BWR LOCA condition. In front of the pipe exit the target disk of 1000 mm in diameter was installed. The distance between the pipe exit and the target was 500 mm. 13 pressure transducers and 13 thermocouples were mounted on the target disk to measure the pressure and temperature increase due to jet impingement on the target. (author)

  7. Contralateral breast cancer adjacent to a fibroadenoma: report of a case.

    Science.gov (United States)

    Iwamoto, Miki; Takei, Hiroyuki; Iida, Shinya; Yamashita, Kouji; Yanagihara, Keiko; Kurita, Tomoko; Tsuchiya, Shinichi; Kanazawa, Yoshikazu; Uchida, Eiji

    2014-01-01

    A 64-year-old woman noticed a lump of the right breast and consulted our outpatient clinic. She had undergone multiple excisional biopsies of fibroadenomas in both breasts and mastectomy for invasive ductal carcinoma (IDC) of the left breast. After completing 5 years of treatment with adjuvant tamoxifen, she had undergone screening with annual physical examinations and occasional computed tomography. She was declared recurrence-free 13 years after breast cancer surgery, although lumps were detected in the right breast, probably due to fibroadenomas. Mammography, ultrasonography, and magnetic resonance imaging revealed that the lump was irregularly shaped, 2 cm in diameter, and adjacent to a fibroadenoma with macrocalcification. Two axillary lymph nodes were enlarged and suggestive of metastasis. A core needle biopsy revealed IDC of the right breast. She underwent a right partial mastectomy with axillary lymph node dissection. The IDC was 2 cm in diameter, of nuclear grade 2, and adjacent to a 0.7-cm fibroadenoma with a macrocalcification. The margins of the IDC close to the fibroadenoma were clearly demarcated by the fibrous capsule of the fibroadenoma. Four axillary lymph nodes were positive for metastasis. In the present case the presence of fibroadenoma might have interfered with the early detection of the contralateral IDC. The history of multiple excisions of fibroadenomas and mastectomy for breast cancer suggests an increased risk of contralateral breast cancer for the patient's entire life; therefore, regular annual follow-up, such as physical examinations and mammography, is recommended.

  8. Diameter growth performance of tree functional groups in Puerto Rican secondary tropical forests

    Directory of Open Access Journals (Sweden)

    Patricia Adame

    2014-04-01

    Full Text Available Aim of study: Understanding the factors that control tree growth in successional stands is particularly important for quantifying the carbon sequestration potential and timber yield of secondary tropical forests. Understanding the factors that control tree growth in successional stands is particularly important for quantifying the carbon sequestration potential and timber yield of secondary tropical forests. Yet, the high species diversity of mixed tropical forests, including many uncommon species, hinders the development of species-specific diameter growth models.Area of study: In these analyses, we grouped 82 species from secondary forests distributed across 93 permanent plots on the island of Puerto Rico.Material and Methods: Species were classified according to regeneration strategy and adult height into six functional groups. This classification allowed us to develop a robust diameter growth model using growth data collected from 1980-1990. We used mixed linear model regression to analyze tree diameter growth as a function of individual tree characteristics, stand structure, functional group and site factors.Main results: The proportion of variance in diameter growth explained by the model was 15.1%, ranging from 7.9 to 21.7%. Diameter at breast height, stem density and functional group were the most important predictors of tree growth in Puerto Rican secondary forest. Site factors such as soil and topography failed to predict diameter growth.Keywords: Caribbean forests; growth model; tropical forest succession; Puerto Rico.

  9. Study of mammography in mass screening for breast cancer

    International Nuclear Information System (INIS)

    Kitada, Masahiro; Sakai, Hiroko; Kubo, Yoshihiko; Samejima, Natsuki; Kurowarabi, Kunio; Iwabuchi, Shuji.

    1995-01-01

    In order to examine the rate of correct diagnosis by mammography at initial mass screening for breast cancer, we carried out a retrospective study of mammography findings in 267 cases of breast cancer detected at Asahikawa Cancer Screening Center. The screening was performed by physical examination, and in cases where disease was suspected, mammography, ultrasonography, and needle biopsy were done. Mammographically, 172 cases (64.4%) were cancer-positive, 58 cases (21.7%) were suspicious for cancer, and 37 cases (13.9%) were cancer-negative. Patients below 50 years of age and those with tumors of small diameter (<20 mm) showed a significantly lower rate of cancer positivity than patients aged 50 years or more and those with tumors 20 mm or more in diameter. Mammographic abnormalities were not specific, since these changes were also found in normal subjects and patients with benign diseases. Therefore, we concluded that mammography without physical examination at initial mass screening has a high risk of missing breast cancer. Mass screening for breast cancer should be performed by physical examination involving inspection and palpation at the first instance. If any suspicious findings are obtained, mammography, ultrasonography, and needle biopsy should be done. (author)

  10. Breast carcinomas: variations in sonoelastographic appearance

    Directory of Open Access Journals (Sweden)

    Fleury E

    2014-08-01

    Full Text Available Eduardo de Faria Castro Fleury,1 Maria do Carmo Guedes Alcoforado Assunção-Queiros,2 Decio Roveda Jr1 1Faculdade de Cências Médicas da Santa Casa de São Paulo, São Paulo, Brazil; 2Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil Background: This study assessed factors influencing the sonoelastographic presentation of breast carcinoma. Methods: A prospective collaborative study was conducted by the Santa Casa de São Paulo and CTC-Center, on 540 breast lesions in women referred for percutaneous breast biopsy. Eighty-four carcinomas showing lesions on ultrasonography were included. These lesions were classified into four sonoelastographic scores, where scores of 1, 2, and 3 were considered false-negative, and a score of 4 was considered true-positive. Scores were compared against histopathologic results, which were divided into two groups, ie, soft lesions (group 1 and hard lesions (group 2. False-negative and true-positive results were also assessed for variation according to patient age and mean lesion diameter. Results: Of the 84 lesions studied, nine yielded false-negative results on sonoelastography and 75 yielded true-positive results. In terms of histopathologic classification, eight were assigned to group 1 and 76 to group 2. The chi-squared test showed a correlation between sonoelastographic scores and histopathologic lesion type. No statistically significant differences were observed according to patient age or largest lesion diameter. Conclusion: Our results revealed an association between sonoelastographic presentation of breast lesions and histology. False-negative results on sonoelastography were influenced by histologic type of lesion and not by lesion size or patient age. Keywords: ultrasound, breast, carcinoma, elastography

  11. Correlation between PET/CT results and histological and immunohistochemical findings in breast carcinomas

    International Nuclear Information System (INIS)

    Bitencourt, Almir Galvao Vieira; Lima, Eduardo Nobrega Pereira; Chojniak, Rubens; Marques, Elvira Ferreira; Souza, Juliana Alves de; Graziano, Luciana; Andrade, Wesley Pereira; Osorio, Cynthia Aparecida Bueno de Toledo

    2014-01-01

    Objective: to correlate the results of 18 F-fluoro-2-deoxy-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) performed with a specific protocol for assessment of breasts with histological/immunohistochemical findings in breast carcinoma patients. Materials and methods: cross-sectional study with prospective data collection, where patients with biopsy-confirmed breast carcinomas were studied. The patients underwent PET/CT examination in prone position, with a specific protocol for assessment of breasts. PET/CT findings were compared with histological and immunohistochemical data. Results: the authors identified 59 malignant breast lesions in 50 patients. The maximum diameter of the lesions ranged from 6 to 80 mm (mean: 32.2 mm). Invasive ductal carcinoma was the most common histological type (n = 47; 79.7%). At PET/CT, 53 (89.8%) of the lesions demonstrated anomalous concentrations of 18 F-FDG, with maximum SUV ranging from 0.8 to 23.1 (mean: 5.5). A statistically significant association was observed between higher values of maximum SUV and histological type, histological grade, molecular subtype, tumor diameter, mitotic index and Ki-67 expression. Conclusion: PET/CT performed with specific protocol for assessment of breasts has demonstrated good sensitivity and was associated with relevant histological/immunohistochemical factors related to aggressiveness and prognosis of breast carcinomas. (author)

  12. Evaluation of a Hanging-Breast PET System for Primary Tumor Visualization in Patients With Stage I-III Breast Cancer: Comparison With Standard PET/CT.

    Science.gov (United States)

    Teixeira, Suzana C; Rebolleda, José Ferrér; Koolen, Bas B; Wesseling, Jelle; Jurado, Raúl Sánchez; Stokkel, Marcel P M; Del Puig Cózar Santiago, María; van der Noort, Vincent; Rutgers, Emiel J Th; Valdés Olmos, Renato A

    2016-06-01

    The purposes of this study were to evaluate the performance of a mammography with molecular imaging PET (MAMMI-PET) system for breast imaging in the hanging-breast position for the visualization of primary breast cancer lesions and to compare this method with whole-body PET/CT. Between March 2011 and March 2014, a prospective evaluation included women with one or more histologically confirmed primary breast cancer lesions (index lesions). After injection of 180-240 MBq of (18)F-FDG, whole-body PET/CT and MAMMI-PET acquisitions were performed, index lesions were scored 0, 1, or 2 for FDG uptake relative to background. Detection and FDG uptake were compared by breast length, maximal tumor diameter, affected breast quadrants, tumor grade, and histologic and immunologic sub-types. Finally, the two PET modalities were compared for detection of index lesions. For 234 index lesions (diameter, 5-170 mm), the overall sensitivity was 88.9% for MAMMI-PET and 91% for PET/CT (p = 0.61). Twenty-three (9.8%) index lesions located too close to the pectoral muscle were missed with MAMMI-PET, and 20 index lesions were missed with PET/CT. Lesion visibility on MAMMI-PET images was influenced by tumor grade (p = 0.034) but not by cancer subtype (p = 0.65). Although in an overall evaluation MAMMI-PET was not superior to PET/CT, MAMMI-PET does have higher sensitivity for primary breast cancer lesions within the scanning range of the device. Optimization of the positioning device may increase visualization of the most dorsal lesions.

  13. [Specific features of mammographic visualization of "small" breast tumors developing on the background of fibrocystic disease].

    Science.gov (United States)

    Bukharin, D G; Velichko, S A; Slonimskaia, E M; Frolova, I G; Luneva, S V; Garbukov, E Iu; Doroshenko, A V

    2011-01-01

    All complications diagnosed at early stages of breast cancer were associated with small tumors, especially with those arising in the aftermath of fibrocystic disease. Hence, our task was to study the XR-semiotics of lesions of less than 15 mm in diameter and of the same origin. 100 mammograms of breast cancer patients with benign disease of the breast were studied. The presence of moderate-to-severe fibrocystic disease significantly affected the visualization of lesions of less than 10 mm in diameter. Since the XR-semiotics of small tumors failed to reveal malignancy features, all lesions visualized by mammography required additional diagnostic procedures using ultrasound and invasive radiology.

  14. Optical biopsy of breast tissue using differential path-length spectroscopy

    International Nuclear Information System (INIS)

    Veen, Robert L P van; Amelink, Arjen; Menke-Pluymers, Marian; Pol, Carmen van der; Sterenborg, Henricus J C M

    2005-01-01

    Differential path-length spectroscopy (DPS) was used to determine the local optical properties of breast tissue in vivo. DPS measurements were made on healthy and malignant breast tissue using a fibre-optic needle probe, and were correlated to the histological outcome of core-needle biopsies taken from the same location as the measurements. DPS yields information on the local tissue blood content, the local blood oxygenation, the average micro-vessel diameter, the β-carotene concentration and the scatter slope. Our data show that malignant breast tissue is characterized by a significant decrease in tissue oxygenation and a higher blood content compared to normal breast tissue

  15. 12-inch x-ray image intensifier with thin metal input window

    Energy Technology Data Exchange (ETDEWEB)

    Obata, Yoshiharu; Anno, Hidero; Harao, Norio [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1982-08-01

    Borosilicate glass has been used for X-ray input window of image intensifiers (I.I.) up to now. Now two new types of 12-inch metal I.I., RT12301C and RT12302C, have been developed. They use convex 1-mm aluminum (instead of 5-mm borosilicate glass) for the input window. Adopting a high-performance penta-electronic lens and a new type of light guide CsI film, these intensifiers have greatly improved contrast, quantum detection efficiency (QDE) and resolution capability. In spite of low dosage, image quality equivalent to that in the conventional direct radiograph is obtained through combined use of the new-type 12-inch metal I.I. with 0.3-mm small-focal-spot X-ray tube. Great contribution to digital radiography is expected of this I.I.

  16. Metastasis of breast cancer rectum

    International Nuclear Information System (INIS)

    Suárez, L.; Santander, G.

    2004-01-01

    Introduction: Metastases to the breast are rare, corresponding approximately to 3% of breast cancers. Primary tumors that spread more commonly are own breast, often following them in melanomas, neuroendocrine, ovarian and lymphoma. Medical history: A 59-year consultation rectoragias repeated and thinning. It is studied and finally intervenes (low anterior resection) diagnosed with rectal cancer whose Histopathology revealed a poorly differentiated adenocarcinoma stage III. Concomitantly the patient has a left breast lump that was studied with mammography, which revealed a dense mass of larger diameter 4 cm in topografiada 3 hour left breast with well defined contours and ultrasonographic structure solid. MI lumpectomy is performed whose pathology reports a poorly differentiated adenocarcinoma with cytoarchitectural features matching the lesion of rectum. Hormone receptors were negative. The patient is treated as a rectal cancer with RT spread over QT (5FU i /c). Died 7 months after diagnosis. Discusion: In literature are reported only 3 cases of breast metastases secondary to rectal cancer; how unusual this presentation justify this report.In this event they occurred in patients with a previous diagnosis of rectal cancer and in the context of systemic lesion progression. In our case clinician early diagnosis of rectal and breast metastases was synchronous. The mammographic image consistent with those described for these cases in the literature.The development of metastases in breast tissue is associated with a poor prognosis as which correlates with the survival of the patient

  17. Immediate breast reconstruction using autologous skin graft associated with breast implant.

    Science.gov (United States)

    Dutra, A K; Andrade, W P; Carvalho, S M T; Makdissi, F B A; Yoshimatsu, E K; Domingues, M C; Maciel, M S

    2012-02-01

    Immediate breast reconstruction with skin graft is still little mentioned in the literature. Follow-up studies regarding the technique aspects are particularly scarce. The objective was to detail immediate breast reconstruction using autologous skin graft. Patients (n = 49) who underwent mastectomies and autologous immediate breast reconstruction with skin graft associated with a breast implant at A. C. Camargo Hospital (São Paulo, Brazil) between January 2007 and July 2010 were included. Information on clinical data, technique details and clinical outcome were prospectively collected. Following mastectomy, the autologous full-thickness skin graft was obtained through an inframammary fold incision along the contralateral breast in most patients. The skin graft was placed on the surface of the pectoralis major muscle after adjustments to conform to the mastectomy defect. A minimum of 10-month follow-up period was established. Patients' age ranged from 35 to 55 years and all received a silicone gel textured surface implant to obtain the necessary breast mound. The mean surgical time was 45 min, and the mean amount of skin resection was 4.5 cm in the largest diameter. Follow-up ranged from 10 to 35 months (median 23). All patients had silicone-gel textured surface implants to perform the breast mound reconstruction. No complications were observed in 87.8% of reconstructions. Forty-six patients (94%) had no complaints about the donor-site aesthetics. The result was a breast mound with a central ellipse of healed skin graft. Three (6%) poor results were observed. Thirty-six patients (67%) reported the results as good or very good. Our results lead us to conclude that autologous skin graft provided a reliable option in immediate breast reconstruction to skin-sparing mastectomy defects. The technique accomplished a single-stage implant breast reconstruction when there is inadequate skin coverage. Copyright © 2011 British Association of Plastic, Reconstructive and

  18. Breast-conserving surgery in locally advanced breast cancer submitted to neoadjuvant chemotherapy. Safety and effectiveness based on ipsilateral breast tumor recurrence and long-term follow-up

    Directory of Open Access Journals (Sweden)

    Guilherme Freire Angotti Carrara

    Full Text Available OBJECTIVE: To evaluate ipsilateral breast tumor recurrence after breast-conserving surgery for locally advanced breast cancer. METHODS: A retrospective observational cohort study was performed in patients with locally advanced breast cancer submitted to breast-conserving surgery after neoadjuvant chemotherapy based on an adriamycin-cyclophosphamide-paclitaxel regimen. We evaluated the clinical, pathologic, immunohistochemistry, and surgical factors that contribute to ipsilateral breast tumor recurrence and locoregional recurrence. A Kaplan-Meier analysis and Cox model were used to evaluate the main factors related to disease-free survival. RESULTS: Of the 449 patients who received neoadjuvant chemotherapy, 98 underwent breast-conserving surgery. The average diameter of the tumors was 5.3 cm, and 87.2% reached a size of up to 3 cm. Moreover, 86.7% were classified as clinical stage III, 74.5% had T3-T4 tumors, 80.5% had N1-N2 axilla, and 89.8% had invasive ductal carcinoma. A pathologic complete response was observed in 27.6% of the tumors, and 100.0% of samples had free margins. The 5-year actuarial overall survival rate was 81.2%, and the mean follow-up was 72.8 months. The rates of ipsilateral breast tumor recurrence and locoregional recurrence were 11.2% and 15.3%, respectively. Multifocal morphology response was the only factor related to ipsilateral breast tumor recurrence disease-free survival (p=0.04. A multivariate analysis showed that the pathologic response evaluation criteria in solid tumors (RECIST-breast cutoff was the only factor related to locoregional recurrence disease-free survival (p=0.01. CONCLUSIONS: Breast-conserving surgery is a safe and effective therapy for selected locally advanced breast tumors.

  19. Avoiding preoperative breast MRI when conventional imaging is sufficient to stage patients eligible for breast conserving therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pengel, Kenneth E., E-mail: k.pengel@nki.nl [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Loo, Claudette E. [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Wesseling, Jelle [Department of Pathology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Pijnappel, Ruud M. [Department of Radiology/Image Sciences Institute, University Medical Center Utrecht Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Rutgers, Emiel J.Th. [Department of Surgical Oncology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Gilhuijs, Kenneth G.A. [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Radiology/Image Sciences Institute, University Medical Center Utrecht Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2014-02-15

    Aim: To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT). Methods: We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC). Results: MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68. Conclusions: It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted.

  20. Avoiding preoperative breast MRI when conventional imaging is sufficient to stage patients eligible for breast conserving therapy

    International Nuclear Information System (INIS)

    Pengel, Kenneth E.; Loo, Claudette E.; Wesseling, Jelle; Pijnappel, Ruud M.; Rutgers, Emiel J.Th.; Gilhuijs, Kenneth G.A.

    2014-01-01

    Aim: To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT). Methods: We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC). Results: MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68. Conclusions: It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted

  1. Correlation between PET/CT results and histological and immunohistochemical findings in breast carcinomas

    Directory of Open Access Journals (Sweden)

    Almir Galvão Vieira Bitencourt

    2014-04-01

    Full Text Available Objective To correlate the results of 18F-fluoro-2-deoxy-D-glucose (18F-FDG positron emission tomography/computed tomography (PET/CT performed with a specific protocol for assessment of breasts with histological/immunohistochemical findings in breast carcinoma patients. Materials and Methods Cross-sectional study with prospective data collection, where patients with biopsy-confirmed breast carcinomas were studied. The patients underwent PET/CT examination in prone position, with a specific protocol for assessment of breasts. PET/CT findings were compared with histological and immunohistochemical data. Results The authors identified 59 malignant breast lesions in 50 patients. The maximum diameter of the lesions ranged from 6 to 80 mm (mean: 32.2 mm. Invasive ductal carcinoma was the most common histological type (n = 47; 79.7%. At PET/CT, 53 (89.8% of the lesions demonstrated anomalous concentrations of 18F-FDG, with maximum SUV ranging from 0.8 to 23.1 (mean: 5.5. A statistically significant association was observed between higher values of maximum SUV and histological type, histological grade, molecular subtype, tumor diameter, mitotic index and Ki-67 expression. Conclusion PET/CT performed with specific protocol for assessment of breasts has demonstrated good sensitivity and was associated with relevant histological/immunohistochemical factors related to aggressiveness and prognosis of breast carcinomas.

  2. Wegener’s granulomatosis of the breast: A case report

    International Nuclear Information System (INIS)

    Szabo-Moskal, Jadwiga

    2014-01-01

    Differential diagnosis and detection of malignant lesions in mammography poses a challenge for many diagnosticians. Although mammography continues to be the best and cost-effective way to detect breast cancer, it has its limitations due in part to the radiological appearance of changes of a very rare condition. We are presented with changes that have met well-known radiologic criteria for the diagnosis of malignancy, yet they turn out to be benign, because they belong to a group of extraordinary lesions. In June 2010, a 56-year-old woman found a lump in her right breast. Mammography performed at another medical center, revealed a change 12 mm in diameter, rated as BI-RADS 4C. Physical examination revealed a palpable lesion, 15 mm in diameter. Ultrasonography revealed hypoechogenic change with ill-defined outlines, size 14×10 mm – BI-RADS 5. Fine needle aspiration biopsy was done and revealed no atypical cells. The patient underwent an open surgical biopsy and a histopathological diagnosis was suggested to be a type of Wegener’s granulomatosis. Exclusion of cancer enabled the continuation of medical treatment of the underlying disease. There were no changes in the breast in follow-up studies. The differential diagnosis of breast tumors should include rare conditions that can sometimes mimic breast cancer. One of them is Wegener’s granulomatosis. Both, the diagnosis and treatment of the disease, require the cooperation of specialists from various fields, including clinicians, pathologists and radiologists

  3. Point and Fixed Plot Sampling Inventory Estimates at the Savannah River Site, South Carolina.

    Energy Technology Data Exchange (ETDEWEB)

    Parresol, Bernard, R.

    2004-02-01

    This report provides calculation of systematic point sampling volume estimates for trees greater than or equal to 5 inches diameter breast height (dbh) and fixed radius plot volume estimates for trees < 5 inches dbh at the Savannah River Site (SRS), Aiken County, South Carolina. The inventory of 622 plots was started in March 1999 and completed in January 2002 (Figure 1). Estimates are given in cubic foot volume. The analyses are presented in a series of Tables and Figures. In addition, a preliminary analysis of fuel levels on the SRS is given, based on depth measurements of the duff and litter layers on the 622 inventory plots plus line transect samples of down coarse woody material. Potential standing live fuels are also included. The fuels analyses are presented in a series of tables.

  4. Child seat belt guidelines: Examining the 4 feet 9 inches rule as the standard.

    Science.gov (United States)

    Morse, Amber M; Aitken, Mary E; Mullins, Samantha H; Miller, Beverly K; Pomtree, Mindy M; Ulloa, Erin M; Montgomery, Jeffrey S; Saylors, Marie E

    2017-08-01

    Current American Academy of Pediatrics recommendations regarding transition from child safety/booster seat to adult safety belt use indicate that children should be at least 4 feet 9 inches, 8 years old, or 80 pounds. Proper fit in the vehicle seat, assessed with a five-point fit test, should also be met. Although most children reach 4 feet 9 inches around age 8 years, each child and vehicle presents a unique combination; thus a child may not fit appropriately in all vehicle types using only the 4 feet 9 inches requirement. We enrolled children, aged 7 years to 12 years, into our study. Height, weight, and demographic data were obtained. A Child Passenger Safety Technician then performed the five-point fit test in each of a uniform lineup of five vehicles. Data were collected on fit in the standard vehicle seat and also in a booster seat. We set 90% as the threshold proportion of children who meet all criteria for proper fit to validate current recommendations of a height of 4 feet 9 inches. Data were collected on 388 children. The percentage of 90% proper fit was met in the compact car and small sport-utility vehicle (SUV). However, only 80 (77%) of 104 students (p vehicles (large SUVs and trucks). This emphasizes the need for evaluation of fit by a trained personnel and/or development of standard back seat dimensions in all vehicles for maximum safety. Epidemiologic study, level III; Therapeutic study, level V.

  5. Worcester 1 Inch Solenoid-Actuated Gas-Operated VPS System Ball Valve

    International Nuclear Information System (INIS)

    VAN KATWIJK, C.

    2000-01-01

    1 inch Gas-operated full-port ball valve incorporates a solenoid and limit switches as integral parts of the actuator. The valve is normally open and fails safe to the closed position. The associated valve position switch is class GS

  6. Conservative treatment versus mastectomy in breast cancer tumors with macroscopic diameter of 20 millimeters or less. The experience of the Institut Gustave-Roussy

    International Nuclear Information System (INIS)

    Sarrazin, D.; Le, M.; Roueesse, J.; Contesso, G.; Petit, J.Y.; Lacour, J.; Viguier, J.; Hill, C.

    1984-01-01

    A clinical trial was conducted at the Institut Gustave Roussy between October 1972 and December 1980 to compare mastectomy with local excision plus Cobalt-irradiation, in patients with breast cancer tumors of 20 mm in diameter or less at macroscopic examination. Low-axillary dissection and extemporaneous histologic examination were carried out for all patients. If one or more positive nodes were found, complete axillary dissection was performed. The study included 179 patients. No significant difference was detected in either overall or relapse-free survival between the two groups, although the conservatively treated group showed slightly better results. The results of conservative treatment were esthetically satisfactory in 92% of the cases. The trial included a second randomization for the patients with positive axillary nodes to assess the value of nodal area irradiation; 72 patients were studied in this part of the trial. No significant differences were found between the two groups after adjustment for the number of positive axillary nodes, although the no-nodal irradiation group showed better results and less complications than the nodal irradiation group

  7. Usefulness of Thallium Scan for Differential Diagnosis of Breast Mass

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Sang Kyun; Yum, Ha Yong; Lee, Chung Han; Choi, Kyung Hyun [Kosin University College of Medicine, Pusan (Korea, Republic of)

    1994-07-15

    The purpose of this study is to evaluate thallium scanning as a potential test in differentiating malignant from benign lesions of breast. Thirty-one female patients underwent thallium scan of the breast. After intravenous injection of 74-111 MBq(2-3 mCi)of thallium-201, anterior and lateral images were obtained. We compared thallium scans with pathological results. Of 11 patients with breast cancers, 10 cases (90.9%) were detected using thallium scan. Thallium scan obtained in one patient who had breast cancer but received several cycles of chemotherapy did not show thallium uptake. The smallest detectable cancer was 1.5 cm in diameter. In contrast, there is no thallium accumulation in breasts of 17 of 20 patients with benign disease (85%), Three cases of 13 fibrocystic disease show thallium uptake in their breast. In conclusion, thallium scan is an effective test in differentiating benign from malignant lesion.

  8. Usefulness of Thallium Scan for Differential Diagnosis of Breast Mass

    International Nuclear Information System (INIS)

    Bae, Sang Kyun; Yum, Ha Yong; Lee, Chung Han; Choi, Kyung Hyun

    1994-01-01

    The purpose of this study is to evaluate thallium scanning as a potential test in differentiating malignant from benign lesions of breast. Thirty-one female patients underwent thallium scan of the breast. After intravenous injection of 74-111 MBq(2-3 mCi)of thallium-201, anterior and lateral images were obtained. We compared thallium scans with pathological results. Of 11 patients with breast cancers, 10 cases (90.9%) were detected using thallium scan. Thallium scan obtained in one patient who had breast cancer but received several cycles of chemotherapy did not show thallium uptake. The smallest detectable cancer was 1.5 cm in diameter. In contrast, there is no thallium accumulation in breasts of 17 of 20 patients with benign disease (85%), Three cases of 13 fibrocystic disease show thallium uptake in their breast. In conclusion, thallium scan is an effective test in differentiating benign from malignant lesion.

  9. [Application of serratus anterior muscle flap combined with breast implants for breast reconstruction after modified radical mastectomy].

    Science.gov (United States)

    Chai, Lijun; Zhang, Xuehui

    2017-09-01

    To investigate effectiveness of the combination of serratus anterior muscle flap and breast implants for breast reconstruction after modified radical mastectomy. Between January 2015 and December 2015, 25 female patients with breast cancer were enrolled, aged 24-62 years (mean, 40.6 years). The tumor located at left side in 9 cases and right side in 16 cases; 14 cases were in the left upper quadrant, 4 cases were in the left lower quadrant, 7 cases were on the top of the breast. All cases were invasive ductal carcinoma. According to TNM staging, 14 cases were at stageⅠand 11 cases were at stageⅡA. The diameter of lumps were all less than 3 cm. All those lumps were solitary and without distant metastasis. The sentinel nodes were all negative. After modified radical mastectomy, the breasts were reconstructed by serratus anterior muscle flap and breast implants. The nipples were spared in 22 cases. The operation time was 113-148 minutes (mean, 136 minutes). All breasts survived and incisions healed at stageⅠ. There was no complication such as hematoma, infection, etc . All patients were followed up 6-18 months (mean, 15 months). Except 1 case, the others were evaluated according to the criteria of the reconstructed breast at 12 months after operation. Among them, 23 cases were evaluated as good and 1 case as fair. There was no tumor recurrence during the follow-up period. The combination of serratus anterior muscle flap and breast implants after the modified radical mastectomy is a handy approach of breast reconstruction which is less harmful with few postoperative complications. It also gains a high degree of satisfaction from patients for good breast shape.

  10. Child seat belt guidelines: Examining the 4 feet 9 inches rule as the standard.

    Science.gov (United States)

    Morse, Amber M; Aitken, Mary E; Mullins, Samantha H; Miller, Beverly K; Pomtree, Mindy M; Ulloa, Erin M; Montgomery, Jeffrey S; Saylors, Marie E

    2017-11-01

    Current American Academy of Pediatrics recommendations regarding transition from child safety/booster seat to adult safety belt use indicate that children should be at least 4 feet 9 inches, 8 years old, or 80 pounds. Proper fit in the vehicle seat, assessed with a five-point fit test, should also be met. Although most children reach 4 feet 9 inches around age 8 years, each child and vehicle presents a unique combination; thus a child may not fit appropriately in all vehicle types using only the 4 feet 9 inches requirement. We enrolled children, aged 7 years to 12 years, into our study. Height, weight, and demographic data were obtained. A Child Passenger Safety Technician then performed the five-point fit test in each of a uniform lineup of five vehicles. Data were collected on fit in the standard vehicle seat and also in a booster seat. We set 90% as the threshold proportion of children who meet all criteria for proper fit to validate current recommendations of a height of 4 feet 9 inches. Data were collected on 388 children. The percentage of 90% proper fit was met in the compact car and small sport-utility vehicle (SUV). However, only 80 (77%) of 104 students (p guidelines for an adult seat belt do not meet safety requirements for fit, especially in larger, commonly used vehicles (large SUVs and trucks). This emphasizes the need for evaluation of fit by a trained personnel and/or development of standard back seat dimensions in all vehicles for maximum safety. Epidemiologic level 1.

  11. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2005-01-01

    Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple cast-iron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1 (Program Management) and Task 2 (Establishment of Detailed Design Specifications) were completed in prior quarters while Task 3 (Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves) has progressed to installing prototype sleeves in cast-iron test pipe segments. Efforts in the current quarter continued to focus on Tasks 4-8. Highly valuable lessons were learned from field tests of the 4-inch gas pipe repair robot in cast-iron pipe at Public Service Electric & Gas. (These field tests were conducted and reported last quarter.) These tests identified several design issues which need to be implemented in both the small- and large-diameter

  12. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2004-11-01

    & Fabricate Large Diameter Live Access System) progressed to completing the detailed design of the entry fitting for 12-inch diameter cast iron pipe in the previous quarter. Field tests with the 4-inch size fitting were completely successful and did not reveal any significant design issues. The primary suggestion from the PSE&G field crew was to produce a version which completely bolts together and does not require a long seam weld. This could be used in low-pressure cast iron mains to reduce installation time. A bolt-on version is now being designed based on this recommendation. Task 8 (System Integration and Laboratory Validation) continued with the development of the robot module inter-connects and of a master LabView-based system display and control software.

  13. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari, Gerard T. Pittard

    2004-01-01

    optimize the design of the robot elements and surface control electronics and software. Task 6 (Design & Build Surface Control and Monitoring System) has been completed with the control and computer display functions being operated through LabView. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to the design, fabrication and testing of a entry fitting in a 4-inch prototype and is now being used to complete drawings for use in 12-inch diameter pipe. Task 8--System Integration and Laboratory Validation continued developing the robot module inter-connects and development of a master LabView-based system display and control software.

  14. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M Kothari; Gerard T. Pittard

    2004-07-01

    ) continued with additional in-pipe testing required to optimize the design of the robot elements and surface control electronics and software. Task 6 (Design & Build Surface Control and Monitoring System) has been completed with the control and computer display functions being operated through LabView. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to completing the detailed design of the entry fitting for 12-inch diameter cast iron pipe. The fitting is now being manufactured. The 12-inch ball valve for allowing no-blow access was also procured. Task 8 (System Integration and Laboratory Validation) continued with the development of the robot module inter-connects and of a master LabView-based system display and control software.

  15. Mastectomy or breast conserving surgery? Factors affecting type of surgical treatment for breast cancer – a classification tree approach

    International Nuclear Information System (INIS)

    Martin, Michael A; Meyricke, Ramona; O'Neill, Terry; Roberts, Steven

    2006-01-01

    A critical choice facing breast cancer patients is which surgical treatment – mastectomy or breast conserving surgery (BCS) – is most appropriate. Several studies have investigated factors that impact the type of surgery chosen, identifying features such as place of residence, age at diagnosis, tumor size, socio-economic and racial/ethnic elements as relevant. Such assessment of 'propensity' is important in understanding issues such as a reported under-utilisation of BCS among women for whom such treatment was not contraindicated. Using Western Australian (WA) data, we further examine the factors associated with the type of surgical treatment for breast cancer using a classification tree approach. This approach deals naturally with complicated interactions between factors, and so allows flexible and interpretable models for treatment choice to be built that add to the current understanding of this complex decision process. Data was extracted from the WA Cancer Registry on women diagnosed with breast cancer in WA from 1990 to 2000. Subjects' treatment preferences were predicted from covariates using both classification trees and logistic regression. Tumor size was the primary determinant of patient choice, subjects with tumors smaller than 20 mm in diameter preferring BCS. For subjects with tumors greater than 20 mm in diameter factors such as patient age, nodal status, and tumor histology become relevant as predictors of patient choice. Classification trees perform as well as logistic regression for predicting patient choice, but are much easier to interpret for clinical use. The selected tree can inform clinicians' advice to patients

  16. One-inch field of view imaging probe for breast cancer sentinel node location

    International Nuclear Information System (INIS)

    D'Errico, Giovanni; Scafe, Raffaele; Soluri, Alessandro; Schiaratura, Alfiero; Maria Mangano, Anna; David, Vincenzo; Scopinaro, Francesco

    2003-01-01

    The already reported 1-in. 2 field of view mini gamma camera known since 1998 with the name of Imaging Probe (IP), has been used for sentinel node localization by a medical equipe that, though trained by the group of nuclear physicians of the University 'La Sapienza' who first conceived and used this detector, has used IP in its own Hospital to: (1) gain experience for future use during operations--a cooperative work on IP radio guided orthopaedic operations has already started working, and (2) to start with IP multicenter trials. In six patients with breast cancer, who underwent lymphoscintigraphy for sentinel node biopsy, sentinel node was checked and located with IP and non-imaging Neoprobe 2000 CdTe (Zn) probe, independent of location by means of large field of view Anger camera. Operators who used Neoprobe and IP were blinded to each other and not aware of the results of Anger camera imaging. Anger camera, as well as IP and neoprobe detected 7 nodes in 6 pts. Detection time was 2', 06'' SD 26'' with IP and 2', 18'' SD 47'' with neoprobe 2000. The most difficult to find node required 2 min and 56 s--inside sd--for IP detection and 3 min and 45 s with neoprobe. Subjective impression of being sure of having detected sentinel node was: absolutely sure on 7/7 nodes with IP and on 5/7 nodes with neoprobe

  17. Survey of the Role of Combined Screening Method with Ultrasonography in the Diagnosis of Breast Cancer

    Directory of Open Access Journals (Sweden)

    F. Gharekhanloo

    2011-01-01

    Full Text Available Introduction & Objective: The breast cancer is the most common malignancy in women and in recent years it is seen in younger ages. Because of dense breast tissue in these ages, the mammography sensitivity for breast cancer detection is reduced, so high quality ultrasonography (US as a combined screening method is effective. The aim of this study is the evaluation of the mammographic finding with the positive finding of ultrasonogarphy.Materials & Methods: In this cross-sectional study 300 cases were referred to the Mehr Medical Imaging Center for breast US and sonography of breast and axilla was performed. Mammography before or after US was also performed by another radiologist. All suspicious patients were referred for biopsy or surgery.Results: Mean age of patients was 46 y/o with the range of 32-76 y/o. Pathologic specimens approved malignancy in 21 patients and abscess in 1 patient. The most frequent symptom was palpable breast mass with mean diameter of 29 mm. Mean diameter of lymph nodes was 17.3 mm. Positive mammographic findings were seen in 85.7%and negative findings or only an asymmetric density in 14.3%.Conclusion: According to dense breast tissue especially in young women sensitivity of single screening by mammography is reduced in breast cancer detection, so combined screening with sonography and mammography especially in younger women improves the detection rate of breast carcinoma. (Sci J Hamadan Univ Med Sci 2011;17(4:57-60

  18. Usefulness limitation of 3D-ultrasound diagnosis of breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Yong Seok; Chung, Soo Young; Yang, Ik; Lee, Kyung Won; Kim, Hong Dae; Shin, Sang Joon; Chung, Bong Wha [College of Medicine, Hallym Univ., Seoul (Korea, Republic of)

    2001-09-01

    To compare 3D ultrasound (3D-US) with 2D ultrasound (2D-US) in terms of their usefulness and limitations in the diagnosis of breast masses. We obtained 2D and 3D US images of 37 breast lesions present in 20 cases of fibroadenoma, nine of cancer, and eight of fibrocystic disease proven in a total of 26 cases [ fibroadenoma (n=13), breast cancer (n=9), fibrocystic disease (n=4)] by histologic examination, and by clinical evaluation and clinical evaluation with sonographic imaging in eleven. When comparing 3D and 2D-US images we had no prior information regarding detection rate according to the size of lesions, whether or not internal and boundary echo patterns could be interpreted, accurate differentiation between tumorous and non-tumorous lesions, or the accuracy with which benign and malignant tumors could be differentiated. For lesions of 1 cm or less in diameter the detection rate of 3D-US was lower than that of 2D-US, but for lesions over 1 cm there was no difference between the two modalities. In fibroadenoma and breast cancer, 3D-US was more useful than 2D-US for the evaluation of both internal and boundary echo, but with fibrocystic disease and in the diagnosis of tumor/non-tumor, there was no significant difference. In breast cancer, however, 3D-US more accurately determined malignancy, and in fibroadenoma, because of the pseudospicule revealed by 3D-US, this modality was less exact in determining benignancy. In the evaluation of internal and boundary echo in breast mass diagnosis, 3D-US was more useful than its 2D counterpart. For lesions of 1 cm or less in diameter, however, the detection rate of 3D-US was more useful than its 2D counterpart. For lesions of 1 cm or less in diameter, however, the detection rate of 3D-US was low, and since in some benign cases a pseudospicule was apparent, the possibility of confusion with malignancy arose. For these reasons, the usefulness of 3D-US was limited.

  19. Usefulness limitation of 3D-ultrasound diagnosis of breast masses

    International Nuclear Information System (INIS)

    Cheon, Yong Seok; Chung, Soo Young; Yang, Ik; Lee, Kyung Won; Kim, Hong Dae; Shin, Sang Joon; Chung, Bong Wha

    2001-01-01

    To compare 3D ultrasound (3D-US) with 2D ultrasound (2D-US) in terms of their usefulness and limitations in the diagnosis of breast masses. We obtained 2D and 3D US images of 37 breast lesions present in 20 cases of fibroadenoma, nine of cancer, and eight of fibrocystic disease proven in a total of 26 cases [ fibroadenoma (n=13), breast cancer (n=9), fibrocystic disease (n=4)] by histologic examination, and by clinical evaluation and clinical evaluation with sonographic imaging in eleven. When comparing 3D and 2D-US images we had no prior information regarding detection rate according to the size of lesions, whether or not internal and boundary echo patterns could be interpreted, accurate differentiation between tumorous and non-tumorous lesions, or the accuracy with which benign and malignant tumors could be differentiated. For lesions of 1 cm or less in diameter the detection rate of 3D-US was lower than that of 2D-US, but for lesions over 1 cm there was no difference between the two modalities. In fibroadenoma and breast cancer, 3D-US was more useful than 2D-US for the evaluation of both internal and boundary echo, but with fibrocystic disease and in the diagnosis of tumor/non-tumor, there was no significant difference. In breast cancer, however, 3D-US more accurately determined malignancy, and in fibroadenoma, because of the pseudospicule revealed by 3D-US, this modality was less exact in determining benignancy. In the evaluation of internal and boundary echo in breast mass diagnosis, 3D-US was more useful than its 2D counterpart. For lesions of 1 cm or less in diameter, however, the detection rate of 3D-US was more useful than its 2D counterpart. For lesions of 1 cm or less in diameter, however, the detection rate of 3D-US was low, and since in some benign cases a pseudospicule was apparent, the possibility of confusion with malignancy arose. For these reasons, the usefulness of 3D-US was limited

  20. Breast MR imaging in women at high-risk of breast cancer. Is something changing in early breast cancer detection?

    International Nuclear Information System (INIS)

    Sardanelli, Francesco; Podo, Franca

    2007-01-01

    In the last few years, several papers have addressed the introduction of contrast-enhanced MR imaging for screening women at high risk for breast cancer. Taking in consideration five prospective studies, on 3,571 screened women with hereditary predisposition to the disease and 9,652 rounds, we found that 168 patients were diagnosed with breast cancer (155 screen-detected, eight interval, and five cancers excluded from analysis) with a detection rate per year of 1.7%. These cancers were small (49% equal to or less than 10 mm in diameter) but aggressive, 82% being invasive and 49% with histologic grade 3; however, only 19% of these invasive cancers were associated with nodal involvement. The pooled sensitivity was 16% for clinical breast examination, 40% for mammography, 43% for ultrasound, and 81% for MR. The positive predictive value (calculated on the basis of the number of invasive diagnostic procedures due to false positives) was 33%, 47%, 18%, and 53%, respectively. Aim of the present article is to present the historical development of MR imaging of breast tumors that made this application theoretically and technically possible, to explain what strategic problems we face in the presence of a hereditary predisposition to the disease, to review the main results of the published studies, and to outline open problems and future perspectives. (orig.)

  1. Worcester 1 Inch Solenoid-Actuated Gas Operated SCHe System Valves

    International Nuclear Information System (INIS)

    VAN KATWIJK, C.

    2000-01-01

    1 inch Gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fail closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated

  2. Flooding experiments with steam and water in a large diameter vertical tube

    International Nuclear Information System (INIS)

    Williams, S.N.; Solom, M.; Draznin, O.; Choutapalli, I.; Vierow, K.

    2009-01-01

    An experimental study on flooding in a large diameter tube is being conducted. In a countercurrent, two-phase flow system, flooding can be defined as the onset of flow reversal of the liquid component which results in cocurrent flow. Flooding can be perceived as a limit to two-phase countercurrent flow, meaning that pairs of liquid and gas flow rates exist that define the envelope for stable countercurrent flow for a given system. Flooding in the AP600 pressurizer surge line can affect the vessel refill rate following a small break LOCA. Analysis of hypothetical severe accidents with current simplified flooding models show that these models represent the largest uncertainty in steam generator tube creep rupture. During a hypothetical station blackout scenario without auxiliary feedwater recovery, should the hot leg become voided, the pressurizer liquid will drain to the hot leg and flooding may occur in the surge line. Experiments have been conducted in a 3-inch (76.2 mm) diameter tube with subcooled water and superheated steam as the working fluids at atmospheric pressure. Water flows down the inside of the tube as an annulus while the steam flows upward in the middle. Water flow rates vary from 3.5 to 12 GPM (0.00022 to 0.00076 m 3 /s) and the water inlet temperature is about 70degC. The steam inlet temperature is about 110degC. It was found that a larger steam flow rate was needed to achieve flooding for a lower water flow rate and for a higher water flow rate. This unique data for flooding in steam-water systems in large diameter tubes will reduce uncertainty in flooding models currently utilized in reactor safety codes. (author)

  3. Health physics challenges involved with opening a "seventeen-inch" concrete waste vault.

    Science.gov (United States)

    Sullivan, Patrick T; Pizzulli, Michelle

    2005-05-01

    This paper describes the various activities involved with opening a sealed legacy "Seventeen-inch" concrete vault and the health physics challenges and solutions employed. As part of a legacy waste stream that was removed from the former Hazardous Waste Management Facility at Brookhaven National Laboratory, the "Seventeen-inch" concrete vault labeled 1-95 was moved to the new Waste Management Facility for ultimate disposal. Because the vault contained 239Pu foils with a total activity in excess of the transuranic waste limits, the foils needed to be removed and repackaged for disposal. Conventional diamond wire saws could not be used because of facility constraints, so this project relied mainly on manual techniques. The planning and engineering controls put in place enabled personnel to open the vault and remove the waste while keeping dose as low as reasonably achievable.

  4. Metaplastic Breast Cancer and EGFR Expression

    Directory of Open Access Journals (Sweden)

    Nilufer Avci

    2014-03-01

    Full Text Available Aim: Metaplastic breast cancer has poor prognosis and is usually triple negative. Although it is morphologically more heterogeneous than triple negative breast cancers, expression profile is more homogeneous. In this study, we investigated our metaplastic breast cancer cases regarding their pathology and clinical characteristics. Material and Method: 16 metaplastic breast cancer cases from four different center were included in the study. Pathology and clinical characteristics of the cases were evaluated retrospectively. Results: All the cases are female and median age is 48 (39-45. Tumor is commonly localized to the outer quadrant and mean diameter of the mass is 37.5 (15-100 mm. Tumor diameter is ≤20 mm in 3 (15.8%, >20-≤50 mm in 11 (57.9% and >50 mm in 3 (10.51% of the cases. Only 4 (16.1% patients have axillary lymph node involvement. When considering histological subtypes, five of the cases has squamous cell, five of them has spindle cell, one of them has mucoepidermoid, and in five cases the subtype was not identified. Considering hormone receptor status ER and PR was negative in 78.9%, 63.2% respectively. HER2 protein expression was positive by immunohistochemical staining in 1 (5.3% case. CK5/6 and CK17 was both positive in 7 (36.8% cases. EGFR expression was positive in 4 (21.1% cases, was negative in 5 (26.3% cases and not identified in 7 (36.8% cases. Three of the cases were offered neoadjuvant chemotherapy. As neoadjuvant chemotherapy, anthracycline and taxane combination (n:2 TAC, n:1 AC-paclitaxel was preferred. Mean follow-up was 41 months. Mean survival was 42.4 months in EGFR negative patients and 47.5 months in EGFR positive patients. This difference was not statistically significant. During follow-up 3 cases had recurrence. Discussion: EGFR expression is seen in metaplastic breast cancer. Although EGFR expression is related to poor prognosis, it is not a predictive marker. Therefore, predictive molecular markers are

  5. MLEP-Fail calibration for 1/8 inch thick cast plate of 17-4 steel.

    Energy Technology Data Exchange (ETDEWEB)

    Corona, Edmundo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    The purpose of the work presented in this memo was to calibrate the Sierra material model Multilinear Elastic-Plastic Hardening Model with Failure (MLEP-Fail) for 1/8 inch thick cast plate of 17-4 steel. The calibration approach is essentially the same as that recently used in a previous memo using data from smooth and notched tensile specimens. The notched specimens were manufactured with three notch radii R = 1=8, 1/32 and 1/64 inches. The dimensions of the smooth and notched specimens are given in the prints in Appendix A. Two cast plates, Plate 3 and Plate 4, with nominally identical properties were considered.

  6. A Case of Conjunctival Melanoma Presenting with Breast Metastasis

    Directory of Open Access Journals (Sweden)

    Mustafa Canhoroz

    2014-03-01

    Full Text Available Most breast masses arise from the breast. Metastasis to the breast is fairly uncommon, but can occur in breast skin and parenchyma. In particular, leukemia and lung cancers, and MM may metastasize to the breast. Breast metastasis might be the first symptom or may occur during the course of other malignancies. Our case presented with a fixed mass in the upper-medial quadrant of her left breast during regular follow-up visits. The mean time to breast metastasis in patients with MM is 62 months (13-178. In our case this time was 48 months. In a case series with 7 patients hematological malignancies (Hodgkin lymphoma, non-Hodgkin lymphoma, and leukemia were the leading cause of breast metastasis, whereas in only 1 case the cause was MM. In another case series of 15 MM patients with metastasis to the breast, the primary tumor was frequently localized to the upper extremities and trunk. In a report of 250 conjunctival MM cases the mortality rate was significantly higher in patients with tumors >4 mm in vertical thickness. In another 45-case MM series tumors with a diameter >10 mm were associated with higher mortality rates. In our case the thickness of the tumor was 5 mm. In conclusion, histopathological evaluation should be mandatory in patients with known primary malignancies in order to differentiate new primary tumors, metastases, and benign tumors.

  7. A full Monte Carlo simulation of the YAP-PEM prototype for breast tumor detection

    Science.gov (United States)

    Motta, A.; Righi, S.; Del Guerra, A.; Belcari, N.; Vaiano, A.; De Domenico, G.; Zavattini, G.; Campanini, R.; Lanconelli, N.; Riccardi, A.

    2004-07-01

    A prototype for Positron Emission Mammography, the YAP-PEM, is under development within a collaboration of the Italian Universities of Pisa, Ferrara, and Bologna. The aim is to detect breast lesions, with dimensions of 5 mm in diameter, and with a specific activity ratio of 10:1 between the cancer and breast tissue. The YAP-PEM is composed of two stationary detection heads of 6×6 cm 2, composed of a matrix of 30×30 YAP:Ce finger crystals of 2×2×30 mm 3 each. The EGSnrc Monte Carlo code has been used to simulate several characteristics of the prototype. A fast EM algorithm has been adapted to reconstruct all of the collected lines of flight, also at large incidence angles, by achieving 3D positioning capability of the lesion in the FOV. The role of the breast compression has been studied. The performed study shows that a 5 mm diameter tumor of 37 kBq/cm 3 (1 μCi/cm 3), embedded in active breast tissue with 10:1 tumor/background specific activity ratio, is detected in 10 min with a Signal-to-Noise Ratio of 8.7±1.0. Two hot lesions in the active breast phantom are clearly visible in the reconstructed image.

  8. The 52-inch last-stage blades for steam turbines

    International Nuclear Information System (INIS)

    Suzuki, Atsuhide; Hisa, Shoichi; Nagao, Shin-ichiro; Ogata, Hisao

    1986-01-01

    The last-stage blades (LSB) of steam turbines are one of the most important components determining the plant's maximum capacity and efficiency. The development of LSBs necessitates high-technology including advanced methods of analyses and verifications as well as ample accumulation of technical data. The 52-inch LSB recently developed by Toshiba has raised nuclear power plant's capacity up to 1,300 ∼ 1,800 MW, has effected compact design of turbine units, and has improved thermal efficiency, keeping high reliability. (author)

  9. Radiotherapy as a conservative treatment in breast cancer

    International Nuclear Information System (INIS)

    Pfuhl, O.R. von; Miola, U.J.; Campos, J.C.F. de

    1977-01-01

    The review of 545 cases of cancer of the breast, 10% of which were treated by exclusive radiotherapy, emphasized the trend towards conservative treatment, because 29,8% of mastectomized women died within two years from the operation with distant metastases. As it is possible with radiotherapy to cause fibrosis or keep inactive breast tumors up to 5 cm diameter for two years or longer, one must consider irradiation as a good option for young women with small tumors. A combination was used of tangencial radiotherapy up to 5.000 rads to the whole breast with a boost dose two weeks later of 3.000 to 4.000 rads by means of intersticial radiotherapy given only to the palpable tumor. This was fulfilled by the afterloading method according to a system described as geometrization of the breast by parallel plates where holes were drilled for the needles. No recurrence was seen in 4 years in the selected group of 12 patients submitted to the mentioned treatment [pt

  10. COLLAGENOUS SPHERULES OF THE BREAST: A DIAGNOSTIC ENIGMA

    Directory of Open Access Journals (Sweden)

    Amrit Kaur

    2016-05-01

    Full Text Available INTRODUCTION Collagenous spherule (CS is an enigmatic finding in a breast lesion involving the lobular acini and ductules and is defined with the presence of eosinophilic intraluminal collagen rich spherules measuring 20-100 microns in diameter, surrounded by flattened myoepithelial cells. 1 It is an uncommon incidental finding in less than 1-2% of biopsies associated with various benign and malignant diseases occurring in isolation or multifocally. 2 A major growing concern surrounding collagenous spherules is that it might be misinterpreted as atypical ductal hyperplasia (ADH, cribriform ductal carcinoma in situ (DCIS, cribriform carcinoma or adenoid cystic carcinoma of breast. We present a case of mobile cystic mass of the breast reported as fibrocystic disease of the breast with focal areas showing adenosis and hyperplastic changes with multiple ducts displayed a peculiar change with the presence of extracellular concentric hyaline material present within the intraluminal space, diagnostic of collagenous spherules.

  11. Failure Diameter Resolution Study

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-19

    Previously the SURFplus reactive burn model was calibrated for the TATB based explosive PBX 9502. The calibration was based on fitting Pop plot data, the failure diameter and the limiting detonation speed, and curvature effect data for small curvature. The model failure diameter is determined utilizing 2-D simulations of an unconfined rate stick to find the minimum diameter for which a detonation wave propagates. Here we examine the effect of mesh resolution on an unconfined rate stick with a diameter (10mm) slightly greater than the measured failure diameter (8 to 9 mm).

  12. Ultrasonographic findings of nonlactiferous breast abscess

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Sung Su; Kim, Hak Hee; Lee, Myung Hee; Rho, Sang Chun; Jung, Seon Ok; Jung, So Leoung; Cha, Eun Sook; Shinn, Kyung Sub [Catholic University Medical College, Seoul (Korea, Republic of)

    1995-04-15

    To evaluate the ultrasonographic features of nonlactiferous breast abscess. We retrospectively reviewed ultrasonograms of 21 cases with surgically and clinically proved nonlactiferous breast abscess. The cases included 17 cases of acute or chronic inflammation and 4 cases of tuberculosis. Location of the lesion was subareolar in 15 cases and peripheral in 6. Mean anteroposterior/transverse diameter ratio was 0.49. Internal echogenicitiy of the lesion was variable, with heterogeneous mixed-echoic echotexture in 18 cases and homogeneous hypoechoic in 3. Margin of the lesion was irregular in 18 cases (85.7%) and posterior sonic enhancement was observed in 17 cases (81%). There were also noted obliteration of adjacent superficial fascia, localized skin thickening, and sinus tract or ductal ectasia in 19 (90.5%), 9 (42.9%), and 9(42.9%) cases respectively. Major ultrasonographic findings of nonlactiferous breast abscess was subareolar located, variable shaped mass with posterior enhancement. Additional findings were fistular formation, loss of superficial fascia, and axillary lymphadenopathy.

  13. Ultrasonographic findings of nonlactiferous breast abscess

    International Nuclear Information System (INIS)

    Hwang, Sung Su; Kim, Hak Hee; Lee, Myung Hee; Rho, Sang Chun; Jung, Seon Ok; Jung, So Leoung; Cha, Eun Sook; Shinn, Kyung Sub

    1995-01-01

    To evaluate the ultrasonographic features of nonlactiferous breast abscess. We retrospectively reviewed ultrasonograms of 21 cases with surgically and clinically proved nonlactiferous breast abscess. The cases included 17 cases of acute or chronic inflammation and 4 cases of tuberculosis. Location of the lesion was subareolar in 15 cases and peripheral in 6. Mean anteroposterior/transverse diameter ratio was 0.49. Internal echogenicitiy of the lesion was variable, with heterogeneous mixed-echoic echotexture in 18 cases and homogeneous hypoechoic in 3. Margin of the lesion was irregular in 18 cases (85.7%) and posterior sonic enhancement was observed in 17 cases (81%). There were also noted obliteration of adjacent superficial fascia, localized skin thickening, and sinus tract or ductal ectasia in 19 (90.5%), 9 (42.9%), and 9(42.9%) cases respectively. Major ultrasonographic findings of nonlactiferous breast abscess was subareolar located, variable shaped mass with posterior enhancement. Additional findings were fistular formation, loss of superficial fascia, and axillary lymphadenopathy

  14. The Effect of Different Competition Indices on Diameter Growth of Individual Tree Growth in Mixed Stands of Caucasion fir and Oriental spruce

    Directory of Open Access Journals (Sweden)

    Aydın Kahriman

    2012-11-01

    Full Text Available The aim of this study is to investigate statistical relations between each of 12 competition indices (both distance-dependent and distance-independent and diameter growth of trees. Also we investigated the relations between each of 12 competition indices together with diameter at breast height and diameter growth. For that reason, six sampling plots (ranging from 1000 to 2000 m2 in size were taken from in mixed stands of Caucasion fir and Oriental spruce located within the Forest Management Districts of Torul and Artvin. Our results from those sampling plots were in agreement with general growth models. Regression analysis between each of competition indexes and diameter growth resulted in coefficients of determination (R2 values ranging from 30 to 64%. The distance-dependent competition indices gave stronger correlations with diameter growth than the distance-independent competition indexes. Coefficients of determination were even higher when competition indexes and dbh were used together as independent variables (R2 = 0.31 - 0.82.

  15. Artist autonomy in a digital era: The case of Nine Inch Nails

    Directory of Open Access Journals (Sweden)

    Steven C. Brown

    2012-09-01

    Full Text Available A 2009 presentation by Michael Masnick (CEO and founder of insight company Floor64 entitled ‘How Trent Reznor and Nine Inch Nails represent the Future of the Music Business’ brought the success of the business models employed by Reznor in distributing Nine Inch Nails’ music into the spotlight. The present review provides a comprehensive timeline of the band circa 2005-2010, evaluating the success of the distribution methods employed in accordance with Masnick’s (2009 proposed business model of connecting with fans and providing them with a reason to buy. The model is conceptualised in the wider context in which Reznor’s distribution methods take place (including a brief consideration of Radiohead’s much cited pay-what-you- want model, addressing the perceived gaps in the model by exploring the involvement of musical preferences; age and consumer purchasing behavior and fan worship. Implications are discussed concerning the applicability of the model for new and emerging bands.

  16. Distance-independent individual tree diameter-increment model for Thuya [Tetraclinis articulata (VAHL. MAST.] stands in Tunisia

    Directory of Open Access Journals (Sweden)

    T. Sghaier

    2013-12-01

    Full Text Available Aim of study: The aim of the work was to develop an individual tree diameter-increment model for Thuya (Tetraclinis articulata in Tunisia.Area of study: The natural Tetraclinis articulata stands at Jbel Lattrech in north-eastern of Tunisia.Material and methods:  Data came from 200 trees located in 50 sample plots. The diameter at age t and the diameter increment for the last five years obtained from cores taken at breast height were measured for each tree. Four difference equations derived from the base functions of Richards, Lundqvist, Hossfeld IV and Weibull were tested using the age-independent formulations of the growth functions. Both numerical and graphical analyses were used to evaluate the performance of the candidate models.Main results: Based on the analysis, the age-independent difference equation derived from the base function Richards model was selected. Two of the three parameters (growth rate and shape parameter of the retained model were related to site quality, represented by a Growth Index, stand density and the basal area in larger trees divided by diameter of the subject tree expressing the inter-tree competition.Research highlights: The proposed model can be useful for predicting the diameter growth of Tetraclinis articulata in Tunisia when age is not available or for trees growing in uneven-aged stands.Keywords: Age-independent growth model; difference equations; Tetraclinis articulata; Tunisia.

  17. Incorporating shape constraints in generalized additive modelling of the height-diameter relationship for Norway spruce

    Directory of Open Access Journals (Sweden)

    Natalya Pya

    2016-02-01

    Full Text Available Background: Measurements of tree heights and diameters are essential in forest assessment and modelling. Tree heights are used for estimating timber volume, site index and other important variables related to forest growth and yield, succession and carbon budget models. However, the diameter at breast height (dbh can be more accurately obtained and at lower cost, than total tree height. Hence, generalized height-diameter (h-d models that predict tree height from dbh, age and other covariates are needed. For a more flexible but biologically plausible estimation of covariate effects we use shape constrained generalized additive models as an extension of existing h-d model approaches. We use causal site parameters such as index of aridity to enhance the generality and causality of the models and to enable predictions under projected changeable climatic conditions. Methods: We develop unconstrained generalized additive models (GAM and shape constrained generalized additive models (SCAM for investigating the possible effects of tree-specific parameters such as tree age, relative diameter at breast height, and site-specific parameters such as index of aridity and sum of daily mean temperature during vegetation period, on the h-d relationship of forests in Lower Saxony, Germany. Results: Some of the derived effects, e.g. effects of age, index of aridity and sum of daily mean temperature have significantly non-linear pattern. The need for using SCAM results from the fact that some of the model effects show partially implausible patterns especially at the boundaries of data ranges. The derived model predicts monotonically increasing levels of tree height with increasing age and temperature sum and decreasing aridity and social rank of a tree within a stand. The definition of constraints leads only to marginal or minor decline in the model statistics like AIC. An observed structured spatial trend in tree height is modelled via 2-dimensional surface

  18. US findings of fibroadenomatoid hyperplasia of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Mi Gyung; Hwang, Mi Soo; Lee, Jae Kyo; Park, Bok Hwan [Yeungnam University College of Medicine, Taegu (Korea, Republic of)

    2000-09-15

    To evaluate the ultrasonographic appearance of fibroadenomatoid hyperplasia of the breast. We retrospectively reviewed US findings including size, shape, border, boundary echo, internal echo, posterior echo, lateral echo, and transverse/anteroposterior diameter of 19 patients (mean age 36.6 years) with pathologically proven fibrodenomatoid hyperplasia. Mammogramas were available in 18 patients. On US size, shape, border, internal echo, boundary echo, posterior echo, lateral echo, the ratio of transverse to anteroposterior diameter were analyzed by two radiologist in agreement. Fifteen of 19 patients presented with palpable masses. On US, the mean size of the masses was 13 mm (range, 4-26 mm). The shape of lesions were round to oval in 10 cases (53%), lobulated in 6 cases (32%), irregular in 3 cases (15%). The borders of the lesions were sharp-well defined in 11 cases (58%), unsharp-ill defined in 8 cases (42%). Fourteen cases(74%) showed fine homogeneous internal echo and 5 cases (26%) showed coarse heterogeneous internal echo. Nonexistent or regular fine boundary echo was shown in 11 cases (58%) and irregular thick boundary echo was shown in 8 cases (42%).Posterior sonic enhancement was shown in 10 cases (53%), posterior sonic shadowing in 6 cases (32%). And three cases (15%) showed no posterior echo. Marked lateral echo was demonstrated in 11 cases (58%). The transverse/anteroposterior diameter ratio ranged between 1.0 and 1.5 in 1 case (5.5%), below 1.0 in 1 case (5.5%), and above 1.5 and 17 cases (89%). Mammogram showed no abnormality in ten patients with dense breast, mass like density in seven patients, and clustered microcalcification in one patient. Fibroadenomatoid hyperplasia was usually presented in fourth decade as a palpable breast mass and common US findings were similar to fibroadenoma. However, histopathologic confirmation was needed for the diagnosis because fibroadenomatoid hyperplasia sometimes showed the US features of malignancy.

  19. Which factors influence MRI-pathology concordance of tumour size measurements in breast cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Rominger, M.; Frauenfelder, T. [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Berg, D. [Urbankrankenhaus Berlin, Anesthesiology, Berlin (Germany); Ramaswamy, A. [University Hospital Marburg, Pathology, Marburg (Germany); Timmesfeld, N. [Philipps University Marburg, Institute for Medical Biometry and Epidemiology, Marburg (Germany)

    2016-05-15

    To assess MRI-pathology concordance and factors influencing tumour size measurement in breast cancer. MRI tumour size (greatest diameter in anatomical planes (MRI-In-Plane) and greatest diameter along main tumour axis (MRI-MPR)) of 115 consecutive breast lesions (59 invasive lobular carcinoma, 46 invasive ductal carcinoma, and 10 ductal carcinoma in situ) was retrospectively compared to size measured at histopathology (pT size (Path-TNM) and greatest tumour diameter as relevant for excision (Path-Diameter; reference standard)). Histopathological tumour types, preoperative palpability, surgical management, additional high-risk lesions, and BI-RADS lesion type (mass versus non-mass enhancements) were assessed as possible influencing factors. Systematic errors were most pronounced between MRI-MPR and Path-TNM (7.1 mm, limits of agreement (LoA) [-21.7; 35.9]), and were lowest between MRI-In-Plane and Path-Diameter (0.2 mm, LoA [-19.7; 20.1]). Concordance rate of MRI-In-Plane with Path-Diameter was 86 % (97/113), overestimation 9 % (10/113) and underestimation 5 % (6/113); BI-RADS mass lesions were overestimated in 7 % (6/81) versus 41 % (13/32) for non-mass enhancements. On multivariate analysis only BI-RADS lesion type significantly influenced MRI-pathology concordance (p < 0.001). 2/59 (3 %) ILC did not enhance. Concordance rate varies according to the execution of MRI and histopathological measurements. Beyond this only non-mass enhancement significantly predicted discordance. (orig.)

  20. Treatment of unilateral giant fibroadenoma by breast reduction skin ...

    African Journals Online (AJOL)

    Background: Giant fibroadenoma (GFA) has been defined as fibroadenoma greater than 5 cm in it's the widest diameter and/or weighing more than 500 g. A benign lesion, its size also raises the possibility of malignancy requiring differentiation from a malignant breast disease. When unilateral GFA presents with a severe ...

  1. Preclinical study of diagnostic performances of contrast-enhanced spectral mammography versus MRI for breast diseases in China.

    Science.gov (United States)

    Wang, Qingguo; Li, Kangan; Wang, Lihui; Zhang, Jianbing; Zhou, Zhiguo; Feng, Yan

    2016-01-01

    To evaluate diagnostic performances of CESM for breast diseases with comparison to breast MRI in China. Sixty-eight patients with 77 breast lesions underwent MR and CESM. Two radiologists interpreted either MRI or CESM images, separately and independently. BI-RADS 1-3 and BI-RADS 4-5 were classified into the suspicious benign and suspicious malignant groups. Diagnostic accuracy parameters were calculated. Receiver operating characteristic (ROC) curves were constructed for the two modalities. The agreement and correlation between maximum lesion diameter based on CESM and MRI, or CESM and pathology were analyzed. Diagnostic accuracy parameters for CESM were sensitivity 95.8 %, specificity 65.5 %, PPV 82.1 %, NPV 90.5 % and accuracy 84.4 %. The diagnostic accuracy parameters for breast MRI were sensitivity 93.8 %, specificity 82.8 %, PPV 88.2 %, NPV 92.3 %and accuracy 89.6 %. Area under the curve (AUC) of ROC was 0.96 for breast MRI and 0.88 for CESM. The Bland-Altman plots showed a mean difference of 0.7 mm with 95 % limits of agreement of 11.4 mm in tumor diameter measured using CESM and breast MRI. The differences of size measurement between CESM and breast MRI were significant, whereas no difference was observed between CESM and pathology as well as between breast MRI and pathology. The better correlation with pathological results was found in CESM than breast MRI. Our study demonstrates that CESM possesses better diagnostic performances than breast MRI in terms of diagnostic sensitivity and lesion size assessment. And CESM is a good alternative method of screening breast cancer in high-risk people.

  2. Dedicated breast CT: radiation dose for circle-plus-line trajectory

    International Nuclear Information System (INIS)

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; Noo, Frederic

    2012-01-01

    Purpose: Dedicated breast CT prototypes used in clinical investigations utilize single circular source trajectory and cone-beam geometry with flat-panel detectors that do not satisfy data-sufficiency conditions and could lead to cone beam artifacts. Hence, this work investigated the glandular dose characteristics of a circle-plus-line trajectory that fulfills data-sufficiency conditions for image reconstruction in dedicated breast CT. Methods: Monte Carlo-based computer simulations were performed using the GEANT4 toolkit and was validated with previously reported normalized glandular dose coefficients for one prototype breast CT system. Upon validation, Monte Carlo simulations were performed to determine the normalized glandular dose coefficients as a function of x-ray source position along the line scan. The source-to-axis of rotation distance and the source-to-detector distance were maintained constant at 65 and 100 cm, respectively, in all simulations. The ratio of the normalized glandular dose coefficient at each source position along the line scan to that for the circular scan, defined as relative normalized glandular dose coefficient (RD g N), was studied by varying the diameter of the breast at the chest wall, chest-wall to nipple distance, skin thickness, x-ray beam energy, and glandular fraction of the breast. Results: The RD g N metric when stated as a function of source position along the line scan, relative to the maximum length of line scan needed for data sufficiency, was found to be minimally dependent on breast diameter, chest-wall to nipple distance, skin thickness, glandular fraction, and x-ray photon energy. This observation facilitates easy estimation of the average glandular dose of the line scan. Polynomial fit equations for computing the RD g N and hence the average glandular dose are provided. Conclusions: For a breast CT system that acquires 300-500 projections over 2π for the circular scan, the addition of a line trajectory with equal

  3. [The estimation of systemic chemotherapy treatment administered in breast cancer on lysozyme activity in tears--preliminary report].

    Science.gov (United States)

    Wojciechowska, Katarzyna; Jurowski, Piotr; Wieckowska-Szakiel, Marzena; Rózalska, Barbara

    2012-01-01

    Estimation of cytostatics influence used in breast cancer treatment on lysozyme activity in human tears depend on time of treatment. 8 women were treated at the base of chemotherapy schema: docetaxel with doxorubicin and 4 women treated with schema CMF: cyclophosphamide, methotrexate, 5-fluorouracil. Lysozyme activity in tears was assessed by measurement of diameter zone of Micrococcus lysodeicticus growth inhibition. It was revealed that both chemotherapy schema caused statistically significant reduction of diameter zone of M. lysodeicticus growth inhibition, after first and second course of chemotherapy treatment. After second chemotherapy course CMF schema induced loss of lysozyme activity in patient's tears (zero mm of M. lysodeicticus diameter zone growth inhibition). Systemic chemotherapy administered in breast cancer induce reduction of lysozyme activity in tears, that may cause higher morbidity of ocular surface infections caused by Gram-positive bacteria.

  4. Instability of Reference Diameter in the Evaluation of Stenosis After Coronary Angioplasty: Percent Diameter Stenosis Overestimates Dilative Effects Due to Reference Diameter Reduction

    International Nuclear Information System (INIS)

    Hirami, Ryouichi; Iwasaki, Kohichiro; Kusachi, Shozo; Murakami, Takashi; Hina, Kazuyoshi; Matano, Shigeru; Murakami, Masaaki; Kita, Toshimasa; Sakakibara, Noburu; Tsuji, Takao

    2000-01-01

    Purpose: To examine changes in the reference segment luminal diameter after coronary angioplasty.Methods: Sixty-one patients with stable angina pectoris or old myocardial infarction were examined. Coronary angiograms were recorded before coronary angioplasty (pre-angioplasty) and immediately after (post-angioplasty), as well as 3 months after. Artery diameters were measured on cine-film using quantitative coronary angiographic analysis.Results: The diameters of the proximal segment not involved in the balloon inflation and segments in the other artery did not change significantly after angioplasty, but the reference segment diameter significantly decreased (4.7%). More than 10% luminal reduction was observed in seven patients (11%) and more than 5% reduction was observed in 25 patients (41%). More than 5% underestimation of the stenosis was observed in 22 patients (36%) when the post-angioplasty reference diameter was used as the reference diameter, compared with when the pre-angioplasty measurement was used and more than 10% underestimation was observed in five patients (8%).Conclusion: This study indicated that evaluation by percent diameter stenosis, with the reference diameter from immediately after angioplasty, overestimates the dilative effects of coronary angioplasty, and that it is thus better to evaluate the efficacy of angioplasty using the absolute diameter in addition to percent luminal stenosis

  5. Background parenchymal enhancement in breast MRIs of breast cancer patients: Impact on tumor size estimation

    International Nuclear Information System (INIS)

    Baek, Ji Eun; Kim, Sung Hun; Lee, Ah Won

    2014-01-01

    Objective: To evaluate whether the degree of background parenchymal enhancement affects the accuracy of tumor size estimation based on breast MRI. Methods: Three hundred and twenty-two patients who had known breast cancer and underwent breast MRIs were recruited in our study. The total number of breast cancer cases was 339. All images were assessed retrospectively for the level of background parenchymal enhancement based on the BI-RADS criteria. Maximal lesion diameters were measured on the MRIs, and tumor types (mass vs. non-mass) were assessed. Tumor size differences between the MRI-based estimates and estimates based on pathological examinations were analyzed. The relationship between accuracy and tumor types and clinicopathologic features were also evaluated. Results: The cases included minimal (47.5%), mild (28.9%), moderate (12.4%) and marked background parenchymal enhancement (11.2%). The tumors of patients with minimal or mild background parenchymal enhancement were more accurately estimated than those of patients with moderate or marked enhancement (72.1% vs. 56.8%; p = 0.003). The tumors of women with mass type lesions were significantly more accurately estimated than those of the women with non-mass type lesions (81.6% vs. 28.6%; p < 0.001). The tumor of women negative for HER2 was more accurately estimated than those of women positive for HER2 (72.2% vs. 51.6%; p = 0.047). Conclusion: Moderate and marked background parenchymal enhancement is related to the inaccurate estimation of tumor size based on MRI. Non-mass type breast cancer and HER2-positive breast cancer are other factors that may cause inaccurate assessment of tumor size

  6. Eighteen cases of small breast cancer: a comparative study of mammography, CT scan and pathology

    International Nuclear Information System (INIS)

    Wu Yaopan; Lin Haogao; Cai Peiqiang; Ouyang Yi; Zhang Weizhang; Lu Bingui

    2003-01-01

    Objective: To improve the early diagnosis of breast cancer through a study of the mammography and CT findings of small breast cancer. Methods: The mammography and CT findings of 18 cases of small breast cancer (φ≤2.0 cm in diameter) were studied and compared with pathological results. Results: The diagnostic accuracy of CT and mammography was 83% and 61%, respectively. There was a statistical difference between both modalities (P<0.05), CT scan was superior to mammography. However, there was no difference between them when assessing the lesion arising in F-type breast. In detecting breast fine cluster of calcification, the sensitivity of mammography was better than CT scan. Conclusion: The patient suspected of small breast cancer should take mammography as the first evaluation. CT scan is reserved for the further investigation. The mammography combined with CT scan can improve the early diagnostic rate of breast cancer

  7. Effectiveness of ultrasonography for diagnosis of breast cancer according to detection opportunity

    International Nuclear Information System (INIS)

    Yasuda, Jun; Kamada, Hidetoshi; Goto, Takeshi

    2007-01-01

    One hundred eighty-five cases of primary breast cancer cases treated surgically at our hospital between January 2001 and December 2005 were divided into three groups based on the disease state at the time of discovery. These three groups included 40 asymptomatic cases detected by breast cancer screening (screening group), 23 cases of benign conditions detected at follow-up (follow-up group), and 122 cases detected as a result of symptoms (symptomatic group). These groups were then evaluated retrospectively to assess the usefulness of ultrasonography (US) for breast cancer detection. The average tumor diameter was 14.0 mm in the screening group, 10.8 mm in the follow-up group, and 24.6 mm in the symptomatic group. In these groups, the sensitivity of US was 90.0%, 95.7%, and 100%, respectively, when each category over 3 was considered as positive. The sensitivity of mammography (MMG) was 85.0%, 73.9%, and 96.7%, respectively. Among three cases that were false-negative by US, two were due only to microcalcification and all three were categorized as 2. The average tumor diameter in 16 cases that were false-negative by MMG was 12.9 mm, and all were invasive cancers. The present results indicate that the sensitivity of US is superior to that of MMG for diagnosis of breast cancer. Regular follow-up using US is thought to contribute to the early detection of small invasive cancers. US is complementary to MMG for detection of breast cancer, and therefore the two techniques together are thought to provide better screening sensitivity. (author)

  8. The usefulness of US with contrast agent on breast tumors

    International Nuclear Information System (INIS)

    Jung, Hye An; Jung, Jung Im; Kim, Hak Hee; Son, Sang Bum; Byun, Jae Young; Lee, Jae Mun; Hahn, Sung Tae; Kim, Choon Yul

    2000-01-01

    To evaluate the usefulness of US with contrast agent breast tumors. Fifteen breast tumors in fourteen patients underwent color Doppler US before and after intravenous injection of a microbubble contrast agent (Levovist, Schering AG, Berlin, Germany). Benign lesions were 8 and malignant lesions were 7 among these. Real-time power Doppler ultrasonographic images were recorded on a videotape and representative images were color-printed. Tumor vascularity was analyzed on real-time images in regard to its presence or absence, and changes in diameter and number of vessels, presence or absence of blush around the vessels. Two observers reached a consensus. Results of malignant tumors were compared with those of benign tumors. Color Doppler signal intensity increased in 12 of 15 cases (80%). Number of vessel increased in 9 of 15 cases (60%) and diameter of vessel increased in 12 of 15 cases (80%). Vascular blush around the enhanced vessel was present in 5 of 15 patients (53%). Color Doppler signal increased in 5 of 8 benign lesions (63%) and 7 of 7 malignant lesions (100%). Number of vessel increased in 4 of 8 benign lesion (50%) and 5 of 7 malignant lesions (71%). Diameter of vessel increased in 5 of 8 benign lesions (63%) and 7 of 7 malignant lesions (100%). Blush around the enhanced vessel was present in one of 8 benign lesions (13%) and 4 of 7 malignant lesions (57%). The time to peak enhancement was shorter in malignant cases (mean=45 sec) than benign cases (mean=82 sec). US with contrast agent on breast tumors is effective to detect blood flow within the mass and may be helpful to differentiate malignant from benign lesions.

  9. WE-EF-207-06: Dedicated Cone-Beam Breast CT with Laterally-Shifted Detector: Monte Carlo Evaluation of X-Ray Scatter Distribution and Scatter-To-Primary Ratio

    International Nuclear Information System (INIS)

    Shi, L; Vedantham, S; Karellas, A

    2015-01-01

    Purpose: To determine the spatial distribution of x-ray scatter and scatter-to-primary ratio (SPR) in projections during cone-beam breast CT (CBBCT) with laterally-shifted detector that results in coronal (fan-angle) truncation. Methods: We hypothesized that CBBCT with coronal truncation would lower SPR due to reduction in irradiated breast volume, and that the location of maximum x-ray scatter fluence (scatter-peak) in the detector plane can be determined from the ratio of irradiated-to-total breast volume, breast dimensions and system geometry. Monte Carlo simulations (GEANT4) reflecting a prototype CBBCT system were used to record the position-dependent primary and scatter x-ray photon fluence incident on the detector without coronal truncation (full fan-angle, 2f=24-degrees) and with coronal truncation (fan-angle, f+ f=12+2.7-degrees). Semi-ellipsoidal breasts (10/14/18-cm diameter, chest-wall to nipple length: 0.75xdiameter, 2%/14%/100% fibroglandular content) aligned with the axis-of-rotation (AOR) were modeled. Mono-energy photons were simulated and weighted for 2 spectra (49kVp, 1.4-mm Al HVL; 60kVp, 3.76-mm Al HVL). In addition to SPR, the scatter maps were analyzed to identify the location of the scatter-peak. Results: For CBBCT without fan-angle truncation, the scatter-peaks were aligned with the projection of the AOR onto the detector for all breasts. With truncated fan-beam, the scatter-peaks were laterally-shifted from the projection of the AOR along the fan-angle direction by 14/38/70-pixels for 10/14/18-cm diameter breasts. The corresponding theoretical shifts were 14.8/39.7/68-pixels (p=0.47, 2-tailed paired-ratio t-test). Along the cone-angle, the shift in scatter-peaks between truncated and full-fan angle CBBCT were 2/2/4 -pixels for 10/14/18-cm diameter breasts. CBBCT with fan-angle truncation reduced SPR by 14/22/28% for 10/14/18-cm diameter breasts. 60kVp reduced SPR by 21–25% compared to 49kVp. Peak SPR for CBBCT with fan-angle truncation

  10. Evaluation of diagnosis of small breast cancer with high frequency and color doppler ultrasound

    International Nuclear Information System (INIS)

    Xia Guobing; Hu Chunhong; Jing Qiulong

    2008-01-01

    Objective: To probe the features of high frequency ultrasonography (HFU) and color Doppler ultrasound (CDU) in the case of small breast cancers in order to evaluate the diagnostic value for small breast cancer with CDU. Methods: The features of HFU and CDU were respective analyzed in 67 small breast masses, the biggest diameter of which was under 2cm identified with pathology. Results Partially characteristic changes of small breast cancers were displayed, and micro-calcification within the mass was an important characteristic, in addition, the Resistant Index (RI) ≥ 0.70 on Pulsed Doppler (PD) and the grade of blood flow on Color Doppler Flow Imaging (CDFI)≥T2 implied much more positive malignancy prediction. Conclusion: HFU integrated with CDU can be used for the early and accurate diagnosis of the small breast cancer. (authors)

  11. Sugar maple height-diameter and age-diameter relationships in an uneven-aged northern hardwood stand

    Science.gov (United States)

    Laura S. Kenefic; R.D. Nyland

    1999-01-01

    Sugar maple (Acer saccharum Marsh.) height-diameter and age-diameter relationships are explored in a balanced uneven-aged northern hardwood stand in central New York. Results show that although both height and age vary considerably with diameter, these relationships can be described by statistically valid equations. The age-diameter relationship...

  12. Assessment of cardiac exposure in left-tangential breast irradiation

    International Nuclear Information System (INIS)

    Vees, H.; Bigler, R.; Gruber, G.; Bieri, S.

    2011-01-01

    Purpose. - To assess the value of treatment-planning related parameters namely, the breast volume; the distance of the inferior field border to diaphragm; and the cardio-thoracic ratio for left-tangential breast irradiation. Patients and methods. - Treatment plans of 27 consecutively left-sided breast cancer patients after breast conserving surgery were evaluated for several parameters concerning heart-irradiation. We measured the heart distance respective to the cardio-thoracic ratio and the distance of the inferior field border to diaphragm, as well as the breast volume in correlation with the irradiated heart volume. Results. - The mean heart and left breast volumes were 504 cm 3 and 672.8 cm 3 , respectively. The mean heart diameter was 13.4 cm; the mean cardio-thoracic ratio 0.51 and the mean distance of the inferior field border to diaphragm was 1.4 cm. Cardio-thoracic ratio (p = 0.01), breast volume (p = 0.0002), distance of the inferior field border to diaphragm (p = 0.02) and central lung distance (p = 0.02) were significantly correlated with the measured heart distance. A significant correlation was also found between cardio-thoracic ratio, breast volume and distance of the inferior field border to diaphragm with the irradiated heart volume measured by V10, V20 and V40. Conclusion. - The verification of parameters like cardio-thoracic ratio, distance of the inferior field border to diaphragm and breast volume in left-sided breast cancer patients may help in determining which patients could benefit from more complex planning techniques such as intensity-modulated radiotherapy to reduced risk of late cardiac injury. (authors)

  13. Drill-Core Scanning for Radioelements by Gamma-Ray Spectrometry

    DEFF Research Database (Denmark)

    Løvborg, Leif; Wollenberg, H.; Rose-Hansen, J.

    1972-01-01

    A system has been developed for the continuous and stepwise scanning of rock drill cores for gamma-ray spectrometric determinations of uranium, thorium, and potassium. The apparatus accomodates 3- to 4-cm-diameter core as it passes two opposing 2-inch diameter by 3-inch- thick NaI(Tl) detectors, ......, disclosing detailed variations of U and Th. Contents of U and Th determined by scanning of drill core were consistent with the gross gamma-ray counting rates measured in the boreholes. ©1972 Society of Exploration Geophysicists......A system has been developed for the continuous and stepwise scanning of rock drill cores for gamma-ray spectrometric determinations of uranium, thorium, and potassium. The apparatus accomodates 3- to 4-cm-diameter core as it passes two opposing 2-inch diameter by 3-inch- thick NaI(Tl) detectors...

  14. Replacement of 13 valves by using an isolation plug in the 20 inches diameter main offshore gas pipeline at Cantarell oil field, Campeche Bay, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Carvahal Reyes, Jorge Omar; Ulloa Ochoa, Carlos Manuel [PEMEX, Exploracion y Produccion, MX (Mexico)

    2009-12-19

    In 2002 we changed 13 valves on deck of one gas production platform called Nohoch-A-Enlace at Cantarell Offshore Oil Field. The 20'' diameter gas pipeline and 200 km of length, transport and deliver gas for others production platforms in the Gas Lift System, So 2 millions of oil barrels per day depends of the operation of this gas pipeline but there was 13 valves on pig traps to be changed after 20 years of service to high pressure (64 to 63 kg/cm{sup 2}). We could not stop the operation of this pipeline and some little gas leaks were eliminated in some parts of the valves. This pipeline has two risers so the gas can be injected by two sides of the ring of 20 Km. So we found the proper technology in order to isolate one riser nad change 8 valves and the isolate the other and change the 5, and the gas lift system never stop during the plug and maintenance operations on platform. In the first isolation plug operation this tool run 20 mts inside the riser and was actionated and resists 65 Kg/cm{sup 2} of gas pressure during 44 hours so we changed 8 valves: 2 of 20'', 2 of 10'', 3 of 4'' and 1 of 8'' diameter. In the second isolation the plug run 30 mts inside the second risers and resist 64 Kg/cm{sup 2} of gas during 46 hours and we changed 5 valves of 20'' diameter. In the paper I will describe all the details of this successful operations and procedures. Also the aspects of Health, Security and Environment that we prepared one year before this operations at platform. Pemex save almost 2.5 millions of dollars because the gas lift system never stop and all valves were changed and now we can run cleaning and inspection tools inside the full ring. We used the first isolation plug in Latin America and we want to share this experience to all the pipeline operators in the world as a good practice in pipeline maintenance using plugging technology in the main and large pipelines of high pressure. (author)

  15. 7 CFR 51.2932 - Damage.

    Science.gov (United States)

    2010-01-01

    ... apparent. (e) Scab spots when cracked or aggregating more than three-eighths inch (9.5 mm) in diameter. (f... scattered and aggregating more than one-fourth inch (6.3 mm) in diameter. (g) Hail when the skin has been...

  16. Cryogenic vacuum pumping at the LBL 88-inch cyclotron

    International Nuclear Information System (INIS)

    Elo, D.; Morris, D.; Clark, D.J.; Gough, R.A.

    1978-09-01

    A cryogenic vacuum pumping panel has been in operation at the 88-inch cyclotron since 1974. The nude pumping panel is located in the acceleration chamber. The pumping surface consists of tubing cooled to 20 0 K by a closed loop helium refrigeration system. The pumping surfaces are shielded from radiation heat loads and water vapors by liquid nitrogen cooled baffles. The panel was designed for an average pumping speed of 14,000 liters/sec. for air. This approximately tripled the total effective pumping on the acceleration chamber from the existing diffusion pumped system, significantly reducing charge exchange losses of heavy ions during acceleration. Design, installation and performance characteristics are described

  17. Metallurgical Evaluation of the Five-Inch Cylindrical Induction Melter

    International Nuclear Information System (INIS)

    Imrich, K.J.

    2000-01-01

    A metallurgical evaluation of the 5-inch cylindrical induction melter (CIM) vessel was performed by the Materials Technology Section to evaluate the metallurgical condition after operating for approximately 375 hours at 1400 to 1500 Degrees Celsius during a 2 year period. Results indicate that wall thinning and significant grain growth occurred in the lower portion of the conical section and the drain tube. No through-wall penetrations were found in the cylindrical and conical sections of the CIM vessel and only one leak site was identified in the drain tube. Failure of the drain tube was associated with a localized over heating and intercrystalline fracture

  18. Effect of Calcifications on Breast Ultrasound Shear Wave Elastography: An Investigational Study.

    Science.gov (United States)

    Gregory, Adriana; Mehrmohammadi, Mohammad; Denis, Max; Bayat, Mahdi; Stan, Daniela L; Fatemi, Mostafa; Alizad, Azra

    2015-01-01

    To investigate the effects of macrocalcifications and clustered microcalcifications associated with benign breast masses on shear wave elastography (SWE). SuperSonic Imagine (SSI) and comb-push ultrasound shear elastography (CUSE) were performed on three sets of phantoms to investigate how calcifications of different sizes and distributions influence measured elasticity. To demonstrate the effect in vivo, three female patients with benign breast masses associated with mammographically-identified calcifications were evaluated by CUSE. Apparent maximum elasticity (Emax) estimates resulting from individual macrocalcifications (with diameters of 2mm, 3mm, 5mm, 6mm, 9mm, 11mm, and 15mm) showed values over 50 kPa for all cases, which represents more than 100% increase over background (~21kPa). We considered a 2cm-diameter circular region of interest for all phantom experiments. Mean elasticity (Emean) values varied from 26 kPa to 73 kPa, depending on the macrocalcification size. Highly dense clusters of microcalcifications showed higher Emax values than clusters of microcalcification with low concentrations, but the difference in Emean values was not significant. Our results demonstrate that the presence of large isolated macrocalcifications and highly concentrated clusters of microcalcifications can introduce areas with apparent high elasticity in SWE. Considering that benign breast masses normally have significantly lower elasticity values than malignant tumors, such areas with high elasticity appearing due to presence of calcification in benign breast masses may lead to misdiagnosis.

  19. Effect of Calcifications on Breast Ultrasound Shear Wave Elastography: An Investigational Study.

    Directory of Open Access Journals (Sweden)

    Adriana Gregory

    Full Text Available To investigate the effects of macrocalcifications and clustered microcalcifications associated with benign breast masses on shear wave elastography (SWE.SuperSonic Imagine (SSI and comb-push ultrasound shear elastography (CUSE were performed on three sets of phantoms to investigate how calcifications of different sizes and distributions influence measured elasticity. To demonstrate the effect in vivo, three female patients with benign breast masses associated with mammographically-identified calcifications were evaluated by CUSE.Apparent maximum elasticity (Emax estimates resulting from individual macrocalcifications (with diameters of 2mm, 3mm, 5mm, 6mm, 9mm, 11mm, and 15mm showed values over 50 kPa for all cases, which represents more than 100% increase over background (~21kPa. We considered a 2cm-diameter circular region of interest for all phantom experiments. Mean elasticity (Emean values varied from 26 kPa to 73 kPa, depending on the macrocalcification size. Highly dense clusters of microcalcifications showed higher Emax values than clusters of microcalcification with low concentrations, but the difference in Emean values was not significant.Our results demonstrate that the presence of large isolated macrocalcifications and highly concentrated clusters of microcalcifications can introduce areas with apparent high elasticity in SWE. Considering that benign breast masses normally have significantly lower elasticity values than malignant tumors, such areas with high elasticity appearing due to presence of calcification in benign breast masses may lead to misdiagnosis.

  20. Water-Reflected 233U Uranyl Nitrate Solutions in Simple Geometry

    International Nuclear Information System (INIS)

    Elam, K.R.

    2001-01-01

    A number of critical experiments involving 233 U were performed in the Oak Ridge National Laboratory Building 9213 Critical Experiments Facility during the years 1952 and 1953. These experiments, reported in Reference 1, were directed toward determining bounding values for the minimum critical mass, minimum critical volume, and maximum safe pipe size of water-moderated solutions of 233 U. Additional information on the critical experiments was found in the experimental logbooks. Two experiments utilizing uranyl nitrate (UO 2 (NO 3 ) 2 ) solutions in simple geometry are evaluated in this report. Experiment 37 is in a 10.4-inch diameter sphere, and Experiment 39 is in a 10-inch diameter cylinder. The 233 U concentration ranges from 49 to 62 g 233 U/l. Both experiments were reflected by at least 6 inches of water in all directions. Paraffin-reflected uranyl nitrate experiments, also reported in Reference 1, are evaluated elsewhere. Experiments with smaller paraffin reflected 5-, 6-, and 7.5-inch diameter cylinders are evaluated in U233-SOL-THERM-004. Experiments with paraffin reflected 8-, 8.5-, 9-, 10-, and 12-inch diameter cylinders are evaluated in U233-SOL-THERM-002. Later experiments with highly-enriched 235 U uranyl fluoride solution in the same 10.4-inch diameter sphere are reported in HEU-SOL-THERM-010. Both experiments were judged acceptable for use as criticality-safety benchmark experiments

  1. Accuracy of determining preoperative cancer extent measured by automated breast ultrasonography.

    Science.gov (United States)

    Tozaki, Mitsuhiro; Fukuma, Eisuke

    2010-12-01

    The aim of this study was to determine the accuracy of measuring preoperative cancer extent using automated breast ultrasonography (US). This retrospective study consisted of 40 patients with histopathologically confirmed breast cancer. All of the patients underwent automated breast US (ABVS; Siemens Medical Solutions, Mountain View, CA, USA) on the day before the surgery. The sizes of the lesions on US were measured on coronal multiplanar reconstruction images using the ABVS workstation. Histopathological measurement of tumor size included not only the invasive foci but also any in situ component and was used as the gold standard. The discrepancy of the tumor extent between automated breast US and the histological examination was calculated. Automated breast US enabled visualization of the breast carcinomas in all patients. The mean size of the lesions on US was 12 mm (range 4-62 mm). The histopathological diagnosis was ductal carcinoma in situ (DCIS) in seven patients and invasive ductal carcinoma in 33 patients (18 without an intraductal component, 15 with an intraductal component). Lesions ranged in diameter from 4 to 65 mm (mean 16 mm). The accuracy of determination of the tumor extent with a deviation in length of <2 cm was 98% (39/40). Automated breast US is thought to be useful for evaluating tumor extent preoperatively.

  2. Scintimammography: The new role of Technetium-99 m Sestamibi imaging for the diagnosis of breast carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Khalkhali, I.; Diggles, L. E.; Cutrone, J. A.; Mishkin, F. S. [Los Angeles Medical Center, Torrance (United States). Dept. of Radiology; Iraniha, S. [Los Angeles Medical Center, Torrance (United States). Surgery

    1997-09-01

    Technetium-99-Sestamibi scintimammography has emerged as a new procedure for the imaging of breast tumors, Currently, a large clinical experience has been developed and the results published. At the present time, the major drawback of this procedure appears to be its low sensitivity for the detection of breast carcinomas smaller than 1 cm in diameter. There are other biologic and technical issues that remain to be overcome to optimally image the breasts. Some of these include: development of a dedicated breast imager using nuclear medicine techniques, development of stereotactic needle localization of the abnormalities that demonstrate focal increase uptake in women with normal mammogram and breast physical examination, manufacturing of a breast compression device so that they can immobilize the breast in place for more adequate imaging, overcoming the issue of unilateral or bilateral diffuse breast uptake that is noted in 7 - 10 percent of the cases and finally determination of optimal dose and imaging factors. This review includes their experience at Harbor-University of California, Los Angeles Medical Center with the use of this agent for breast imaging since 1992.

  3. Scintimammography: The new role of Technetium-99 m Sestamibi imaging for the diagnosis of breast carcinoma

    International Nuclear Information System (INIS)

    Khalkhali, I.; Diggles, L. E.; Cutrone, J. A.; Mishkin, F. S.; Iraniha, S.

    1997-01-01

    Technetium-99-Sestamibi scintimammography has emerged as a new procedure for the imaging of breast tumors, Currently, a large clinical experience has been developed and the results published. At the present time, the major drawback of this procedure appears to be its low sensitivity for the detection of breast carcinomas smaller than 1 cm in diameter. There are other biologic and technical issues that remain to be overcome to optimally image the breasts. Some of these include: development of a dedicated breast imager using nuclear medicine techniques, development of stereotactic needle localization of the abnormalities that demonstrate focal increase uptake in women with normal mammogram and breast physical examination, manufacturing of a breast compression device so that they can immobilize the breast in place for more adequate imaging, overcoming the issue of unilateral or bilateral diffuse breast uptake that is noted in 7 - 10 percent of the cases and finally determination of optimal dose and imaging factors. This review includes their experience at Harbor-University of California, Los Angeles Medical Center with the use of this agent for breast imaging since 1992

  4. First report of a permanent breast 103Pd seed implant as adjuvant radiation treatment for early-stage breast cancer

    International Nuclear Information System (INIS)

    Pignol, Jean-Philippe; Keller, Brian; Rakovitch, Eileen; Sankreacha, Raxa; Easton, Harry; Que, William

    2006-01-01

    Purpose: A new technique of adjuvant partial breast irradiation using 103 Pd permanent breast seed implants (PBSI) is presented. The procedure is performed in a single 1-hour session under local anesthesia. Methods and Materials: Patients referred to a single institution for adjuvant radiotherapy after lumpectomy for an infiltrating ductal carcinoma ≤3 cm in diameter, surgical margin ≥2 mm, no extensive in situ carcinoma, no lymphovascular invasion, and minimal or negative lymph node involvement were offered a PBSI. Results: Between May and December 2004, 31 eligible patients underwent CT scan and ultrasound simulations assessing PBSI feasibility. Fifteen were excluded because of feasibility issues, and 16 received PBSI. A minimal peripheral dose of 90 Gy was prescribed to the planning target volume corresponding to the clinical target volume identified on the CT scan plus a margin of 1 cm. The procedure was well tolerated; 56% of the patients reported no pain during the procedure, and 46% of the patients developed National Cancer Institute Common Toxicity Criteria Grade 1 acute reaction. None experienced toxicity Grade 2 or 3. Conclusions: Permanent breast seed implantation seems feasible and well tolerated on these preliminary clinical data and represents an ultimate step in the reduction of treatment fraction for partial breast irradiation

  5. A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging

    International Nuclear Information System (INIS)

    Gong Xing; Glick, Stephen J.; Liu, Bob; Vedula, Aruna A.; Thacker, Samta

    2006-01-01

    Although conventional mammography is currently the best modality to detect early breast cancer, it is limited in that the recorded image represents the superposition of a three-dimensional (3D) object onto a 2D plane. Recently, two promising approaches for 3D volumetric breast imaging have been proposed, breast tomosynthesis (BT) and CT breast imaging (CTBI). To investigate possible improvements in lesion detection accuracy with either breast tomosynthesis or CT breast imaging as compared to digital mammography (DM), a computer simulation study was conducted using simulated lesions embedded into a structured 3D breast model. The computer simulation realistically modeled x-ray transport through a breast model, as well as the signal and noise propagation through a CsI based flat-panel imager. Polyenergetic x-ray spectra of Mo/Mo 28 kVp for digital mammography, Mo/Rh 28 kVp for BT, and W/Ce 50 kVp for CTBI were modeled. For the CTBI simulation, the intensity of the x-ray spectra for each projection view was determined so as to provide a total average glandular dose of 4 mGy, which is approximately equivalent to that given in conventional two-view screening mammography. The same total dose was modeled for both the DM and BT simulations. Irregular lesions were simulated by using a stochastic growth algorithm providing lesions with an effective diameter of 5 mm. Breast tissue was simulated by generating an ensemble of backgrounds with a power law spectrum, with the composition of 50% fibroglandular and 50% adipose tissue. To evaluate lesion detection accuracy, a receiver operating characteristic (ROC) study was performed with five observers reading an ensemble of images for each case. The average area under the ROC curves (A z ) was 0.76 for DM, 0.93 for BT, and 0.94 for CTBI. Results indicated that for the same dose, a 5 mm lesion embedded in a structured breast phantom was detected by the two volumetric breast imaging systems, BT and CTBI, with statistically

  6. Aspiration of breast abscess under ultrasound guidance: outcome obtained and factors affecting success.

    Science.gov (United States)

    Elagili, Faisal; Abdullah, Norlia; Fong, Liew; Pei, Tan

    2007-01-01

    To assess ultrasonographically (US) guided needle aspiration of breast abscesses as an alternative to surgical incision and drainage. In our prospective study, 30 patients with 31 breast abscesses (one patient had bilateral breast abscess) underwent percutaneous breast abscess drainage under US guidance with local anaesthesia and oral antibiotics between 1 January 2004 and 31 March 2005. These patients consisted of 16 (53.3%) non-lactating and 14 (46.7%) lactating women, with ages ranging from 18 to 68 years (median, 28 years). The racial distribution comprised 26 (86.7%) Malays, three (10%) Chinese and one (3.3%) Indian. All patients had the chief complaint of breast swelling and 25 (83.3%) had breast pain. Clinically, 28 (93.3%) were found to have a palpable mass. Nine (30%) lesions were in the upper outer quadrant of the left breast. US diameters ranged from 1 to 15 cm (median, 4 cm). The pus volumes varied from 1 to 200 mL (median, 14 mL). Fifteen (50%) patients required only a single aspiration, 10 required multiple aspirations and five required incision and drainage. Those patients in whom needle aspiration failed had multiloculated lesions irrespective of abscess volume and size. Needle aspiration with ultrasound guidance is an effective treatment for breast abscess irrespective of abscess volume and size.

  7. The POSEIDON Project

    International Nuclear Information System (INIS)

    Benoit, Ph.

    2009-01-01

    Concerns about clean air and global warming led car manufacturers to develop hybrid cars. A few models already reached the market but the manufacturers anticipate that the production figure will hit the million mark at the horizon 2010. Hybrid cars make an extensive use of power electronics, which implies - relatively - large size semi-conductor components. The initial doping of those components is best made by neutron irradiation, which achieves a better doping uniformity than chemical processes. Silicon doping becomes therefore a growing market for a number of research reactors, in supplement to their medical isotopes productions. With the SIDONIE facility in operation since 1992, the doping of silicon is not a new activity in the BR2 reactor. However, SIDONIE is limited to 5 inch diameter ingots whereas the trend is to 6 inch and 8 inch diameter or even 12 inch. The purpose of POSEIDON (POol Side Equipment for Irradiation and DOping of silicon by Neutrons) is to allow the large scale irradiation of 6 inch and 8 inch diameter silicon ingots

  8. Diameter-speed relation of sprite streamers

    International Nuclear Information System (INIS)

    Kanmae, T; Stenbaek-Nielsen, H C; McHarg, M G; Haaland, R K

    2012-01-01

    Propagation and splitting of sprite streamers has been observed at high temporal and spatial resolution using two intensified high-speed CMOS cameras recording at 10 000 and 16 000 frames per second. Concurrent video recordings from a remote site provided data for triangulation allowing us to determine accurate altitude scales for the sprites. Diameters and speeds of the sprite streamers were measured from the high-speed images, and the diameters were scaled to the reduced diameters based on the triangulated locations. The sprite streamers with larger reduced diameter move faster than those with smaller diameter; the relation between the reduced diameter and speed is roughly linear. The reduced diameters at ≈65-70 km altitude are larger than streamer diameters measured at ground pressure in laboratory discharges indicating a deviation from the similarity law possibly due to the effects of the photoionization and an expansion of the streamer head along its propagation over a long distance. The reduced diameter and speed of the sprite streamers agree well with the diameter-velocity relation proposed by Naidis (2009 Phys. Rev. E 79 057401), and the peak electric field of the sprite streamers is estimated to be approximately 3-5 times the breakdown threshold field. (paper)

  9. Two members of the CERN HPD team present their babies. André Braem (left) holds in his hands a 5-inch glass HPD, while a ceramic HPD for medical applications is shown by Christian Joram. The large detector in the middle is a 10-inch HPD developed for an astrophysics experiment.

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    Two members of the CERN HPD team present their babies. André Braem (left) holds in his hands a 5-inch glass HPD, while a ceramic HPD for medical applications is shown by Christian Joram. The large detector in the middle is a 10-inch HPD developed for an astrophysics experiment.

  10. A comparison of R-22, R-134a, R-410a, and R-407c condensation performance in smooth and enhanced tubes: Part 2, Pressure drop

    Energy Technology Data Exchange (ETDEWEB)

    Eckels, S J; Tesene, B A

    1999-07-01

    This paper reports pressure drops during condensation for R-22, R-134a, R-410a, and R-407c in three enhanced tubes and one smooth tube. The test tubes were a 3/8 inch outer diameter smooth tube, a 3/8 inch outer diameter microfin tube, a 5/16 inch outer diameter microfin tube, and a 5/8 inch outer diameter microfin tube. Pressure drops are reported at four mass fluxes, at two saturation temperatures, and over a range of average qualities in the test tubes. The pressure drops for R-410a were approximately 40% lower than those of R-22 in both tubes. R-407c had 10% to 20% lower pressure drops than R-22, while 134-a had slightly larger pressure drops than R-22. The microfin tube pressure drops were, on average, 40% to 80% higher than those for the smooth tube for all refrigerants. The pressure drop penalty of the microfin tube was shown to decrease with increased quality.

  11. POSEIDON project

    International Nuclear Information System (INIS)

    Benoit, P.

    2007-01-01

    Concerns about clean air and global warming among their customers led car manufacturers to develop hybrid cars. A few models already reached the market but the manufacturers anticipate that the production figure will hit the million mark at the horizon 2010. Hybrid cars make an extensive use of power electronics, which implies - relatively - large size semi-conductor components. The initial doping of those components is best made by neutron irradiation, which achieves a better doping uniformity than chemical processes. Silicon doping becomes therefore a growing market for a number of research reactors, in supplement to their medical isotopes productions. With the SIDONIE facility in operation since 1992, the doping of silicon is not a new activity at BR2. However, SIDONIE is limited to 5 inch diameter ingots whereas the trend is to 6 inch and 8 inch diameter. The purpose of POSEIDON is to allow the large scale irradiation of 6 inch and 8 inch diameter silicon ingots

  12. Heat Exchanger Design and Testing for a 6-Inch Rotating Detonation Engine

    Science.gov (United States)

    2013-03-01

    water-cooled rotating detonation engine ( RDE ) run on hydrogen and air. The change in water temperature as it cooled the engine was used to find the...a quick-response resistance temperature detector (RTD) was used in an uncooled RDE of similar dimension to the cooled RDE to estimate the transient...double-checking my design calculations, providing his experience with cooling the 3-inch RDE , and for providing technical expertise in regard to the

  13. Mucinous Breast Cancer: a Review Study of 5 Year Experience from a Hospital-Based Series of Cases.

    Science.gov (United States)

    Dumitru, Adrian; Procop, Alexandru; Iliesiu, Andreea; Tampa, Mircea; Mitrache, Luminita; Costache, Mariana; Sajin, Maria; Lazaroiu, Anca; Cirstoiu, Monica

    2015-03-01

    Mucinous carcinoma (also known as colloid carcinoma) is a particular type of breast cancer characterized by the presence of extracellular mucin and is linked with a more favorable prognosis than invasive breast carcinoma of no special type. Mucinous carcinoma of the breast is an uncommon form of breast tumor, often presenting as a lobulated, moderately well circumscribed mass on mammography, sonography, and MRI imaging. It accounts for 1 to 7% of all breast cancers. Pure mucinous breast carcinomas are rare and account for about 2% of all primary breast carcinomas. Metastatic disease happens at a lower rate than in other types of invasive carcinoma. We present our 5 year experience with this particular pathology in a retrospective review study. We identified 25 patients with mixed and pure mucinous breast cancer, the tumor size varied greatly from 2 to 19 cm in diameter. A subset of mixed mucinous carcinomas (8 cases) showed neuroendocrine differentiation or other associated premalignant lessions. Mucinous carcinoma of the breast is a rare entity with a favorable prognosis due to low incidence of lymph node metastases. Pure mucinous breast carcinoma has an even rare.

  14. Evaluation of a breast software model for 2D and 3D X-ray imaging studies of the breast.

    Science.gov (United States)

    Baneva, Yanka; Bliznakova, Kristina; Cockmartin, Lesley; Marinov, Stoyko; Buliev, Ivan; Mettivier, Giovanni; Bosmans, Hilde; Russo, Paolo; Marshall, Nicholas; Bliznakov, Zhivko

    2017-09-01

    In X-ray imaging, test objects reproducing breast anatomy characteristics are realized to optimize issues such as image processing or reconstruction, lesion detection performance, image quality and radiation induced detriment. Recently, a physical phantom with a structured background has been introduced for both 2D mammography and breast tomosynthesis. A software version of this phantom and a few related versions are now available and a comparison between these 3D software phantoms and the physical phantom will be presented. The software breast phantom simulates a semi-cylindrical container filled with spherical beads of different diameters. Four computational breast phantoms were generated with a dedicated software application and for two of these, physical phantoms are also available and they are used for the side by side comparison. Planar projections in mammography and tomosynthesis were simulated under identical incident air kerma conditions. Tomosynthesis slices were reconstructed with an in-house developed reconstruction software. In addition to a visual comparison, parameters like fractal dimension, power law exponent β and second order statistics (skewness, kurtosis) of planar projections and tomosynthesis reconstructed images were compared. Visually, an excellent agreement between simulated and real planar and tomosynthesis images is observed. The comparison shows also an overall very good agreement between parameters evaluated from simulated and experimental images. The computational breast phantoms showed a close match with their physical versions. The detailed mathematical analysis of the images confirms the agreement between real and simulated 2D mammography and tomosynthesis images. The software phantom is ready for optimization purpose and extrapolation of the phantom to other breast imaging techniques. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. [Right Hemi-Colectomy for a Metastatic Transverse Colon Tumor from Breast Cancer Following Bilateral Breast Cancer Resection - A Case Report].

    Science.gov (United States)

    Okamura, Shu; Yanagisawa, Tetsu; Ohishi, Kazuhito; Murata, Kohei; Nushijima, Yoichiro; Hamano, Rie; Fukuchi, Nariaki; Ebisui, Chikara; Yokouchi, Hideoki; Kinuta, Masakatsu

    2016-11-01

    We herein report the case of a 75-year-old female patient who underwent 4 surgeries for bilateral breast cancer and its recurrence. When she presented at a clinic with an irritable colon, a fist-sized tumor was palpated in the right upper abdomen at her first medical examination. Abdominal CT scan at the clinic revealed a tumor with a maximum diameter of 10 cm on the right side of the transverse colon and multiple swollen mesenteric lymph nodes. Therefore, the patient was referred to our hospital for surgery. Colonoscopy revealed stenosis of the same lesion with an edematous mucosa and sclerosis. Using immunohistochemistry, a biopsy specimen from the lesion tested positive for CK AE1+AE3, and negative for CD20(-)and CD3 (-). As a result, the tumor was diagnosed as a poorly differentiated adenocarcinoma. We performed right hemicolectomy to avoid her intestinal obstruction. Tumor cells were mainly present at the subserosa, according to HEstaining. Using immunostaining, the cells were tested for the following markers: CDX2(-), GCDFP15(weakly positive), CK7(strongly positive), CD20(partially positive), E R(+), PgR(-), and HER2(1+), characterizing the tumor as metastasis of breast cancer. Although gastro-intestinal metastasis from breast cancer is rare, and colon metastasis is even rarer, it might be necessary to rule out the possibility of a metastatic colon tumor from breast cancer when treating patients with a colon tumor who have undergone surgery for breast cancer.

  16. Scintimammography with {sup 99m}Tc-MDP in the detection of primary breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Piccolo, S.; Lastoria, S.; Muto, P.; Bazzicalupo, L.; Bartiromo, A. [National Cancer Institute, Naples (Italy). Dept. of Nuclear Medicine; Salvatore, M. [CNR, Naples (Italy). Center for Nuclear Medicine

    1997-09-01

    Materials and methods. The diagnostic accuracy of scintimammography with {sup 99m}Tc-MDP was evaluated in 400 consecutive women with clinical or mammographic suspicion of breast cancer, candidate to surgery and/or excisional biopsy. Lateral views of both glands were acquired 5-10 min after the injection of 550-740 MBq of {sup 99m}Tc-MDP. The scintigraphic results were compared to mammograms and classified using the histological findings as gold standard. Results. Mammography was suggestive for cancer in 231 (57 %) suspicious in 49 (12 %) and indeterminate in 120 (31 %) patients. Breast carcinoma was histologically proven in 330 women, benign breast diseases in 70. The tumor size ranged from 4 x 5 to 50 x 60 mm. {sup 99m}Tc-MDP visualized as foci of increased uptake 305/330 cancers (92 %). In particular, in women with indeterminate mammograms the SMM had a diagnostic accuracy of 84 % correctly characterizing 101/120 lesions. Twenty missed cancers had largest diameter {<=} 10 mm, 5 {<=} 15 mm. Lack of {sup 99m}Tc-MDP uptake occurred in 64 out of 70 benign lesions. These lesions were classified as truly negative. Conversely, 3 fibroadenoma and 3 epithelial hyperplasia with moderate or severe atypia were falsely positive. The overall specificity was 91.5 %; the accuracy was 92 % the positive and negative predictive values were respectively 98 % and 72 %. Conclusions. The results obtained in this study suggest that {sup 99m}Tc-MDP scintimammography accurately detects breast carcinomas with largest diameter > 10 mm; it differentiates malignant from benign lesions, and it shows promising insights in characterizing breast abnormalities mammographically indeterminate.

  17. Monte Carlo evaluation of glandular dose in cone-beam X-ray computed tomography dedicated to the breast: Homogeneous and heterogeneous breast models.

    Science.gov (United States)

    Sarno, Antonio; Mettivier, Giovanni; Tucciariello, Raffaele M; Bliznakova, Kristina; Boone, John M; Sechopoulos, Ioannis; Di Lillo, Francesca; Russo, Paolo

    2018-06-07

    In cone-beam computed tomography dedicated to the breast (BCT), the mean glandular dose (MGD) is the dose metric of reference, evaluated from the measured air kerma by means of normalized glandular dose coefficients (DgN CT ). This work aimed at computing, for a simple breast model, a set of DgN CT values for monoenergetic and polyenergetic X-ray beams, and at validating the results vs. those for patient specific digital phantoms from BCT scans. We developed a Monte Carlo code for calculation of monoenergetic DgN CT coefficients (energy range 4.25-82.25 keV). The pendant breast was modelled as a cylinder of a homogeneous mixture of adipose and glandular tissue with glandular fractions by mass of 0.1%, 14.3%, 25%, 50% or 100%, enveloped by a 1.45 mm-thick skin layer. The breast diameter ranged between 8 cm and 18 cm. Then, polyenergetic DgN CT coefficients were analytically derived for 49-kVp W-anode spectra (half value layer 1.25-1.50 mm Al), as in a commercial BCT scanner. We compared the homogeneous models to 20 digital phantoms produced from classified 3D breast images. Polyenergetic DgN CT resulted 13% lower than most recent published data. The comparison vs. patient specific breast phantoms showed that the homogeneous cylindrical model leads to a DgN CT percentage difference between -15% and +27%, with an average overestimation of 8%. A dataset of monoenergetic and polyenergetic DgN CT coefficients for BCT was provided. Patient specific breast models showed a different volume distribution of glandular dose and determined a DgN CT 8% lower, on average, than homogeneous breast model. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. Pre-Operative Planning Using Real-Time Virtual Sonography, an MRI/Ultrasound Image Fusion Technique, for Breast-Conserving Surgery in Patients with Non-Mass Enhancement on Breast MRI: A Preliminary Study.

    Science.gov (United States)

    Ando, Takahito; Ito, Yukie; Ido, Mirai; Osawa, Manami; Kousaka, Junko; Mouri, Yukako; Fujii, Kimihito; Nakano, Shogo; Kimura, Junko; Ishiguchi, Tsuneo; Watanebe, Rie; Imai, Tsuneo; Fukutomi, Takashi

    2018-07-01

    The purpose of this retrospective study was to evaluate the effect of pre-operative planning using real-time virtual sonography (RVS), a magnetic resonance imaging (MRI)/ultrasound (US) image fusion technique on breast-conserving surgery (BCS) in patients with non-mass enhancement (NME) on breast MRI. Between 2011 and 2015, we enrolled 12 consecutive patients who had lesions with NME that exceeded the US hypo-echoic area, in which it was particularly difficult to evaluate the tumor margin. During pre-operative planning before breast-conserving surgery, RVS was used to delineate the enhancing area on the breast surface after additional supine breast MRI was performed. We analyzed both the surgical margin positivity rate and the re-operation rate. All NME lesions corresponded to the index cancer. In all patients, the diameter of the NME lesion was greater than that of the hypo-echoic lesion. The median diameters of the NME and hypo-echoic lesions were 24 mm (range: 12-39 mm) and 8.0 mm (range: 4.9-18 mm), respectively (p = 0.0002). After RVS-derived skin marking was performed on the surface of the affected breast, lumpectomy and quadrantectomy were conducted in 7 and 5 patients, respectively. The surgical margins were negative in 10 (83%) patients. Two patients with positive margins were found to have ductal carcinoma in situ in 1 duct each, 2.4 and 3.2 mm from the resection margin, respectively. None of the patients required additional resection. Although further prospective studies are required, the findings of our preliminary study suggest that it is very well possible that the use of RVS-derived skin marking during pre-operative planning for BCS in patients with NME would have resulted in surgical outcomes similar to or better than those obtained without the use of such marking. Copyright © 2018. Published by Elsevier Inc.

  19. Evaluation of the efficiency of bismuth breast shield in CT chest paediatric examinations

    International Nuclear Information System (INIS)

    Sevillano, D.; Espana, M. L.; Castro, P.; Minguez, C.; Albi, G.; Garcia, E.; Lopez Franco, P.

    2006-01-01

    The aim of this study is to evaluate the efficiency of bismuth breast shield in CT chest paediatric examinations when automatic exposure control techniques are used. The influence in the radiation dose and the image quality has been evaluated with and without the breast shield in the scoutview. In addition the radiation dose in shielded and non-shielded areas has been compared. Measurements were made in a 16 cm diameter cylindrical PMMA phantom simulating a newborn, and older children were simulated controlling the maximum intensities allowed by the automatic exposure control system AutomA. The highest dose reduction (59%) was obtained with AutomA system and when the breast shield is not used in the scoutview. This reduction in the radiation dose does not mean a significant increase of noise level. The use of the breast shield in the scoutview yielded an increase in the radiation dose in non-shielded areas. The use of bismuth breast shield is recommended only after the scoutview in order to optimise the radiation dose in CT chest paediatric examination when using automatic exposure control AutomA. (Author)

  20. NO PLIF imaging in the CUBRC 48-inch shock tunnel

    Science.gov (United States)

    Jiang, N.; Bruzzese, J.; Patton, R.; Sutton, J.; Yentsch, R.; Gaitonde, D. V.; Lempert, W. R.; Miller, J. D.; Meyer, T. R.; Parker, R.; Wadham, T.; Holden, M.; Danehy, P. M.

    2012-12-01

    Nitric oxide planar laser-induced fluorescence (NO PLIF) imaging is demonstrated at a 10-kHz repetition rate in the Calspan University at Buffalo Research Center's (CUBRC) 48-inch Mach 9 hypervelocity shock tunnel using a pulse burst laser-based high frame rate imaging system. Sequences of up to ten images are obtained internal to a supersonic combustor model, located within the shock tunnel, during a single ~10-millisecond duration run of the ground test facility. Comparison with a CFD simulation shows good overall qualitative agreement in the jet penetration and spreading observed with an average of forty individual PLIF images obtained during several facility runs.

  1. NO PLIF imaging in the CUBRC 48-inch shock tunnel

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, N.; Bruzzese, J.; Patton, R.; Sutton, J.; Yentsch, R.; Gaitonde, D.V.; Lempert, W.R. [The Ohio State University, Departments of Mechanical and Aerospace Engineering, Columbus, OH (United States); Miller, J.D.; Meyer, T.R. [Iowa State University, Department of Mechanical Engineering, Ames, IA (United States); Parker, R.; Wadham, T.; Holden, M. [CUBRC, Buffalo, NY (United States); Danehy, P.M. [NASA Langley Research Center, Hampton, VA (United States)

    2012-12-15

    Nitric oxide planar laser-induced fluorescence (NO PLIF) imaging is demonstrated at a 10-kHz repetition rate in the Calspan University at Buffalo Research Center's (CUBRC) 48-inch Mach 9 hypervelocity shock tunnel using a pulse burst laser-based high frame rate imaging system. Sequences of up to ten images are obtained internal to a supersonic combustor model, located within the shock tunnel, during a single {proportional_to}10-millisecond duration run of the ground test facility. Comparison with a CFD simulation shows good overall qualitative agreement in the jet penetration and spreading observed with an average of forty individual PLIF images obtained during several facility runs. (orig.)

  2. Sub-mSV breast XACT scanner: concept and design

    Science.gov (United States)

    Tang, Shanshan; Ren, Liqiang; Samant, Pratik; Chen, Jian; Liu, Hong; Xiang, Liangzhong

    2016-04-01

    Excessive exposure to radiation increases the risk of cancer. We present the concept and design of a new imaging paradigm, X-ray induced acoustic computed tomography (XACT). Applying this innovative technology to breast imaging, one single X-ray exposure can generate a 3D acoustic image, which dramatically reduces the radiation dose to patients when compared to beast CT. A theoretical model is developed to analyze the sensitivity of XACT. A noise equivalent pressure model is used for calculating the minimal radiation dose in XACT imaging. Furthermore, K-Wave simulation is employed to study the acoustic wave propagation in breast tissue. Theoretical analysis shows that the X-ray induced acoustic signal has a 100% relative sensitivity to the X-ray absorption (given that the percentage change in the X-ray absorption coefficient yields the same percentage change in the acoustic signal amplitude), but not to X-ray scattering. The final detection sensitivity is primarily limited by the thermal noise. The radiation dose can be reduced by a factor of 100 compared with the newly FDA approved breast CT. Reconstruction result shows that breast calcification with diameter of 80 μm can be observed in XACT image by using ultrasound transducers with 5.5 MHz center frequency. Therefore, with the proposed innovative technology, one can potentially reduce radiation dose to patient in breast imaging as compared with current x-ray modalities.

  3. Fabrication of a 40-inch diameter ceramic to metal seal for PLT

    International Nuclear Information System (INIS)

    Lewin, G.; Mullaney, D.

    1976-01-01

    The design and fabrication details for the ceramic to metal seal for PLT are presented. The method used for the successful casting and firing of the 90% Al 2 O 3 ceramic body and the subsequent grinding and brazing of the ceramic to 430 S.S. are discussed

  4. Breast cancer imaging with mouse monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Major, P.; Wang Taqui; Unger, M.; Rosenthall, L.

    1989-10-01

    The localization of /sup 111/In-labelled MA5 monoclonal antibody, reactive with a breast tumor associated antigen, was studied in 17 patients. MA5 was selected because (1) it reacts with >95% of primary and metastatic lesions, (2) the recognized antigen is present on the cell surface in vivo and (3) MA5 gives excellent localization in human breast tumor xenografts. Each patient received 2 mg antibody labeled with 5 mCi /sup 111/In and in some cases, 3 mg or 18 mg unlabeled carrier antibody. No serious allergic reactions were noted. There was a large uptake in the liver, less significant uptake in the spleen and bone and minimal accumulation in the bowel. Bone lesions, primary tumors, soft tissue recurrences and lung metastases larger than 3 cm diameter were imaged, while only 1 lesion smaller than 3 cm was detected. Non specific accumulation of tracer was noted at the site of a port-a-cath, in a hematoma, in fibrocystic lesions, and at sites of previous radiation treatment. Extensive fibrosis and poor vascularization characteristic of breast tumors may explain in part the limited sensitivity of the imaging. (orig.).

  5. Optimization of registration template of cone-beam CT guided whole breast irradiation after lumpectomy of breast cancer

    International Nuclear Information System (INIS)

    Wang Dongqing; Li Hongsheng; Zhou Tao; Liu Tonghai; Yu Ningsha; Li Baosheng

    2010-01-01

    Objective: To optimize the registration template of kilovoltage cone-beam CT (CBCT) guided radiotherapy in whole breast irradiation (WBI) after lumpectomy of breast cancer. Methods: From April 2006 to July 2009, twelve patients undergoing WBI with intensity-modulated radiotherapy (IMRT) were recruited in this study. All patients were performed with both conventional planning CT and CBCT integrated on Varian 23EX. Six distinguishable reference points (the diameter 1 mm) around the lumpectomy cavity and the surrounding gland on the planning CT image were marked. The images were manually registered offline based on the breast surface, surgical clips, breast gland, contiguous rib, ipsilateral lung and its external contours, respectively. The same six reference points were then marked on the CBCT image. The performance of the five registration templates was compared using the concept of registration error, while the registration time was taken into account. The registration error was calculated based on the six reference points' translations between the planning CT image and CBCT image, and analyzed with SPSS 13.0 software using one-way ANOVA. Results: The values of the registration error for the breast surface, surgical clips, breast gland, contiguous rib, ipsilateral lung and its external contours were (0.60±0.20), (0.43±0.15), (0.49±0.19), (0.69±0.36) and (0.94±0.49) cm, respectively, and the registration time were (3.8±1.1), (3.0±0.9), (4.7±1.7), (4.3±1.3) and (4.5±1.3) min, respectively. There was no statistical difference between the breast surface, surgical clips and breast gland registration template (t=0.48-1.36, P<0.05), the same result trend to contiguous rib compared with ipsilateral lung (t=2.00, P=0.055), however, there was significant difference between surgical clips and the last two registration methods (t=2.08-4.08, P<0.05). Conclusions: In this initial study with a modest number of patients, surgical clips show a best registration template

  6. Efficacy of helical CT in evaluating local tumor extent of breast cancer

    International Nuclear Information System (INIS)

    Ozaki, Yutaka

    2001-01-01

    The purpose of this study is to clarify the diagnostic accuracy of helical CT (HCT) in the determination of local tumor extent of breast cancer. One hundred forty consecutive patients with breast cancer, including 87 invasive ductal carcinomas without extensive intraductal components (EIC), 44 invasive ductal carcinomas with EIC, 2 non-invasive ductal carcinomas, and 7 invasive lobular carcinomas, were included in the study. Three-dimensional tumor diameter including whole extent was measured on HCT, and the amount of invasion to fat tissue, skin, pectoral muscle, and chest wall was estimated using a three-step scale. These results were then compared with the pathological findings. Breast cancers appeared as areas of high attenuation compared with the surrounding breast tissue in all patients. Tumor extent was correctly diagnosed by HCT to within a maximum difference of 1 cm in 88 patients (63%) and within 2 cm in 122 patients (87%). Sensitivity, specificity, and accuracy in diagnosing muscular invasion of breast cancer using HCT were 100%, 99%, and 99%, respectively. Sensitivity, specificity, and accuracy in diagnosing skin invasion of breast cancer using HCT were 84%, 93%, and 91%, respectively. HCT was able to visualize all of the tumors and detect the correct tumor extent in most patients. (author)

  7. Efficacy of helical CT in evaluating local tumor extent of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Yutaka [Juntendo Univ., Chiba (Japan). Urayasu Hospital

    2001-04-01

    The purpose of this study is to clarify the diagnostic accuracy of helical CT (HCT) in the determination of local tumor extent of breast cancer. One hundred forty consecutive patients with breast cancer, including 87 invasive ductal carcinomas without extensive intraductal components (EIC), 44 invasive ductal carcinomas with EIC, 2 non-invasive ductal carcinomas, and 7 invasive lobular carcinomas, were included in the study. Three-dimensional tumor diameter including whole extent was measured on HCT, and the amount of invasion to fat tissue, skin, pectoral muscle, and chest wall was estimated using a three-step scale. These results were then compared with the pathological findings. Breast cancers appeared as areas of high attenuation compared with the surrounding breast tissue in all patients. Tumor extent was correctly diagnosed by HCT to within a maximum difference of 1 cm in 88 patients (63%) and within 2 cm in 122 patients (87%). Sensitivity, specificity, and accuracy in diagnosing muscular invasion of breast cancer using HCT were 100%, 99%, and 99%, respectively. Sensitivity, specificity, and accuracy in diagnosing skin invasion of breast cancer using HCT were 84%, 93%, and 91%, respectively. HCT was able to visualize all of the tumors and detect the correct tumor extent in most patients. (author)

  8. In line inspection of multi-diameter and high-pressure pipelines in Brazil using combined technologies: magnetic flux leakage and ultrasonic testing

    Energy Technology Data Exchange (ETDEWEB)

    Ginten, Markus; Brockhaus, Stephan; Bouaoua, Nourreddine; Klein, Stefan [ROSEN Technology and Research Center, Lingen (Germany); Bruening, Franz [ROSEN Brazil, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The simultaneous use of the magnetic flux leakage (MFL) method and the ultrasonic testing (UT) method on a single in line inspection (ILI) tool has been identified as a versatile and accurate solution for liquid pipelines. The combination of the two methods is complementary to the restrictions of each other. Also, the overall scope of the inspection is enlarged. General wall thinning and largely corroded areas are accurately and reliably scanned with the UT unit, while very detailed information about pitting corrosion is obtained from the MFL measurement. Blind spots of echo loss, as occasionally observed for the UT channels is compensated by the more robust measurement from the MFL sensors. Consequently, this technology has been the method of choice in an in line inspection project of an onshore long distance pipeline in Brazil, facing a variety of corrosion threats. The pipeline consists of several multi-diameter sections of 18/20 inches and 20/22 inches. Furthermore, the high gravity of product in combination with a height profile, an altitude of 1152 m MSL (Mean Sea Level) had to be crossed, leads to a maximum pressure of 220 bar. These boundary conditions had to be considered during the design of the ILI-tool. The paper discusses the experience made so far with the combined technology MFL and UT. The effective use of the inspection tool for the above mentioned pipeline as well as field results from a previous inspection are described. (author)

  9. BREAST RECONSTRUCTIONS AFTER BREAST CANCER TREATING

    Directory of Open Access Journals (Sweden)

    Erik Vrabič

    2018-02-01

    Full Text Available Background. Breasts are an important symbol of physical beauty, feminity, mothering and sexual desire through the entire history of mankind. Lost of the whole or part of the breast is functional and aesthetic disturbance for woman. It is understandable, that the woman, who is concerned over breast loss, is as appropriate as another person´s concern over the loss of a limb or other body part. Before the 1960, breast reconstruction was considered as a dangerous procedure and it was almost prohibited. Considering the psychological importance of the breast in modern society, the possibility of breast reconstruction for the woman about to undergo a mastectomy is a comforting alternative. We can perform breast reconstruction with autologous tissue (autologous reconstruction, with breast implants and combination of both methods. For autologous reconstruction we can use local tissue (local flaps, or tissue from distant parts of the body (free vascular tissue transfer. Tissue expansion must be performed first, in many cases of breast reconstructions with breast implants. Conclusions. Possibility of breast reconstruction made a big progress last 3 decades. Today we are able to reconstruct almost every defect of the breast and the entire breast. Breast reconstruction rise the quality of life for breast cancer patients. Breast reconstruction is a team work of experts from many medicine specialites. In Slovenia we can offer breast reconstruction for breast cancer patients in Ljubljana, where plastic surgeons from Clinical Department for Plastic Surgery and Burns cooperate with oncologic surgeons. Ten years ago a similar cooperation between plastic surgeons and surgeons of the Centre for Breast Diseases was established in Maribor.

  10. 7 CFR 51.3157 - Damage.

    Science.gov (United States)

    2010-01-01

    ...) When the skin is blistered, cracked, or decidedly flattened; (2) When the normal color of the skin or... exceeds three-sixteenths inch in diameter; (c) Scab or bacterial spot when cracked, or when the aggregate... one-fourth inch in diameter; (e) Drought spots or external gum spots which have an aggregate area...

  11. 7 CFR 51.2340 - Classification of defects.

    Science.gov (United States)

    2010-01-01

    ... inch (9.5 mm) in diameter which materially detract from the appearance, edible or shipping quality When... which seriously detract from the appearance, edible or shipping quality. Leaf or Limbrubs When not... inch (9.5 mm) in diameter. Insects When feeding injury is evident on fruit or any insect is present in...

  12. Variability Among Breast Radiation Oncologists in Delineation of the Postsurgical Lumpectomy Cavity

    International Nuclear Information System (INIS)

    Landis, Daniel M.; Luo Weixiu; Song Jun; Bellon, Jennifer R.; Punglia, Rinaa S.; Wong, Julia S.; Killoran, Joseph H.; Gelman, Rebecca; Harris, Jay R.

    2007-01-01

    Purpose: Partial breast irradiation (PBI) is becoming more widely used. Accurate determination of the surgical lumpectomy cavity volume is more critical with PBI than with whole breast radiation therapy. We examined the interobserver variability in delineation of the lumpectomy cavity among four academic radiation oncologists who specialize in the treatment of breast cancer. Methods and Materials: Thirty-four lumpectomy cavities in 33 consecutive patients were evaluated. Each physician contoured the cavity and a 1.5-cm margin was added to define the planning target volume (PTV). A cavity visualization score (CVS) was assigned (1-5). To eliminate bias, the physician of record was eliminated from the analysis in all cases. Three measures of variability of the PTV were developed: average shift of the center of mass (COM), average percent overlap between the PTV of two physicians (PVO), and standard deviation of the PTV. Results: Of variables examined, pathologic resection volume was significantly correlated with CVS, with larger volumes more easily visualized. Shift of the COM decreased and PVO increased significantly as CVS increased. For CVS 4 and 5 cases, the average COM shift was 3 mm and 2 mm, respectively, and PVO was 77% and 87%, respectively. In multiple linear regression, pathologic diameter >4 cm and CVS ≥3 were significantly associated with smaller COM shift. When CVS was omitted from analysis, PVO was significantly larger with pathologic diameter ≥5 cm, days to planning <36, and older age. Conclusions: Even among radiation oncologists who specialize in breast radiotherapy, there can be substantial differences in delineation of the postsurgical radiotherapy target volume. Large treatment margins may be prudent if the cavity is not clearly defined

  13. Design of a 18F production system at ORNL 86-inch cyclotron

    International Nuclear Information System (INIS)

    Shaeffer, M.C.; Barreto, F.; Datesh, J.R.; Goldstein, B.R.

    1977-01-01

    A target system for the production of 18 F by proton bombardment of H 2 18 O was designed for the ORNL 86-inch cyclotron facility. The system consists of concentric titanium and aluminum cylinders. Oxygen-18-enriched H 2 O circulates through the inner titanium cylinder and through an external heat exchanger with cooling water flowing in the annulus. Yields of 5.0 curies are expected for a 250-μA proton beam current and 24-min irradiation time

  14. Treatment of unilateral giant fibroadenoma by breast reduction skin incision: the inverted "T" technique.

    Science.gov (United States)

    Achebe, J U; Njeze, G E; Okwesili, O R

    2014-01-01

    Giant fibroadenoma (GFA) has been defined as fibroadenoma greater than 5 cm in it's the widest diameter and/or weighing more than 500 g. A benign lesion, its size also raises the possibility of malignancy requiring differentiation from a malignant breast disease. When unilateral GFA presents with a severe breast asymmetry, due to its size, it is not correctable by simple enucleation alone. Postoperative asymmetry from volume and ptosis disparity results, which needs to be addressed at the primary surgery. The inverted "T" technique, which is effective in volume reduction and ptosis correction in breast hypertrophy, can be applied in the treatment of unilateral GFA. This is a retrospective review of all GFA treated by inverted "T" method. A retrospective review was carried out on all patients with GFA treated by inverted "T" skin pattern method over a period of 20 years (January 1988 to December 2007). The procedures were carried out at the University of Nigeria Teaching Hospital and the National Orthopedic Hospital, Enugu. Information, which included patients' demographics, pre-operative assessment, operative findings and outcome of surgery were obtained from the case files of the patients. The degree of ptosis was recorded for each patient. Diagnosis of GFA was made after clinical evaluation and pre-operative tissue biopsy. Immediate results of treatment were based on the patients' satisfaction, visual assessment of symmetry of size of breasts, correction of ptosis and position of nipple areola complex (NAC). A total of 27 patients underwent inverted "T" technique for excision of GFA in their breasts. Their average age was 17.5 years (range 12-25 years) delay in presentation ranged from 2 months to 15 months. In 16 patients (59.2%), the left breast was involved in GFA whilst the tumor occurred on the right breast in 11 (40.7%). The tumor weighed on the average 1500 g (range 655-2200 g). Average diameter of the tumor was 15 cm (range 12-20 cm). All quadrants of the

  15. Reduction mammaplasty and radiation therapy can allow breast conservation in patients with breast cancers not initially treatable by tumor-ectomy; Apport de la plastie mammaire de reduction, associee a la radiotherapie, dans le traitement conservateur des cancers du sein non accessibles a une tumorectomie de premiere intention

    Energy Technology Data Exchange (ETDEWEB)

    Otmezguine, Y.; Calitchi, E.; Cothier, I.; Feuilhade, F.; Le Bourgeois, J.P.; Baruch, J. [Hopital Henri-Mondor, 94 - Creteil (France)

    1997-09-01

    A protocol combining reduction mammaplasty (RM) and radiation therapy was developed as an alternative of mastectomy in patients with breast cancers larger than 3 cm in diameter. This protocol was used in 51 patients between 1983 and 1990. Indications were extensive microcalcifications (n = 17; 33 %) ; residual tumor after neo-adjuvant therapy larger than 4 cm in diameter (n 18 ; 35 %); extensive DCIS (n = 4; 8 %) or tumor located within an area of fibrocystic disease (n = 6; 12 %); presence of a bifocal lesion (n = 12 %); area of fibrocystic disease (n = 6; 12 %); and presence of bifocal lesion (n 6; 12 %). Surgery consisted of tumor-ectomy removing a wide margin of skin and mammary gland, followed by immediate remodeling of the breast, same-side axillary node clearance, and symmetrization of the other breast. A radiation dose of 45 Gy was delivered to the entire mammary gland. Adjuvant therapy was given before and/or after therapy according to the institution`s routine breast cancer protocol. During the mean follow-up of 8.1 years, four patients (8 %) developed a local recurrence, which has treated surgically. The five-year disease-free survival rate was 76 %. The cosmetic result was good or very good in 78% of cases. RM plus RT is a reasonable alternative to mastectomy in patients with large breast cancers, although further work is needed to refine its indications. (authors). 15 refs.

  16. Overview of Breast Cancer in Malaysian Women: A Problem with Late Diagnosis

    Directory of Open Access Journals (Sweden)

    Abdullah N. Hisham

    2004-04-01

    Full Text Available Breast cancer is the most common cancer among Malaysian women. There is a marked geographical difference in the worldwide incidence of breast cancer, with a higher incidence in developed countries compared to developing countries. From 1998 to 2001, new cases of breast cancer presenting to the breast clinics at Hospital Kuala Lumpur and University Malaya Medical Centre, Malaysia, were reviewed; the race, age and stage at presentation were analysed. Of 774 cases seen in Hospital Kuala Lumpur, only 5.2% (40/774 were impalpable breast cancers diagnosed on mammography. The prevalent age group was 40 to 49 years, and the median age was 50 years. The average size of the tumour was 5.4 cm in diameter. Malay women appear to have larger tumours and a later stage at presentation than other ethnic groups; 50% to 60% were in late stages (Stages 3 and 4. During the same period, 752 new cases of breast cancer were seen in the University Malaya Medical Centre. The average tumour size was 4.2 cm, and 30% to 40% were in late stages. The age incidence was similar. The delay in presentation of breast cancer was attributed to a strong belief in traditional medicine, the negative perception of the disease, poverty and poor education, coupled with fear and denial. A prospective, population-based study is required to determine the demographic pattern of breast cancer and the factors delaying presentation. These findings will have important implications in future programmes to promote the early detection of breast cancer, as well as in understanding geographical as well as racial variations in the incidence of breast cancer.

  17. 49 CFR 230.38 - Telltale holes.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Telltale holes. 230.38 Section 230.38... Staybolts § 230.38 Telltale holes. (a) Staybolts less than 8 inches long. All staybolts shorter than 8 inches, except flexible bolts, shall have telltale holes 3/16 inch to 7/32 inch diameter and at least 11...

  18. Evaluation of 3 Inch SN-219 Failure and S and SX Tank Farm Saltwell Piping

    International Nuclear Information System (INIS)

    ELSEN, J.J.

    2000-01-01

    Evaluation of direct buried piping currently in use or designated for future Saltwell pumping in S and SX Farms. Documented evaluation of failed S-103 saltwell pumping transfer line 3 inch SN-219. This evaluation is intended to reflect current status of Saltwell piping, when taken in context with referenced documents

  19. Richness and Abundance of Lianas with Different Diameter Classes in Permanent Plots in the Amazon in Mato Grosso

    Directory of Open Access Journals (Sweden)

    D. G. Ferraz

    2013-11-01

    Full Text Available Lianas are an important component of the structure and diversity of tropical forests and the Amazon biome is one of few natural protected areas that still support the highest level of biodiversity in the world. Generally in disturbed forests high densities of lianas are found than mature forests. The aim of this study is to investigate the richness among families and lianas abundance with different diameter classes in permanent plots in the Amazon of Mato Grosso. To the survey were placed 8 plots of 40 x 250 in a forest fragment that has been management for 30 years, where we sampled lianas species with diameter breast height (DBH ≥ 1 cm. There were sampled 3970 stems in the permanent plots, and the two most abundant were 2 and 6 with 594 and 573 individuals respectively. The richest families were Sapindaceae, Dilleniaceae, Menispermaceae and Fabaceae. These results confirm the hypothesis that disturbed areas have more density of lianas with small DBH.

  20. 7 CFR 51.316 - Injury.

    Science.gov (United States)

    2010-01-01

    ... spots, other similar depressions or scars: (1) When the skin is broken, whether healed or unhealed; (2... spots which affect an area of more than one-fourth inch in diameter. (3) Red skin spots which are thinly... the aggregate affected area of such spots exceeds one-half inch in diameter. (e) Bruises which are not...

  1. 7 CFR 51.311 - Marking requirements.

    Science.gov (United States)

    2010-01-01

    ..., the minimum diameter and weight as designated in table II, shall be plainly stamped, stenciled or... fractions thereof in the following manner: “A” inches or “B” grams, where “A” corresponds to one of the diameter measurements in terms of inches listed in table II and “B” corresponds to the weight measurement...

  2. A new alignment procedure for the South African Astronomical Observatory's 74-inch telescope

    Science.gov (United States)

    Crause, Lisa A.; Booth, John A.; Doss, David; Loubser, Egan; O'Connor, James E.; Sass, Craig; Sickafoose, Amanda A.; Worters, Hannah L.

    2016-07-01

    Considerable effort has gone into improving the performance and reliability of the SAAO's 74-inch telescope. This included replacing the telescope encoders, refining the pointing model and increasing the telescope throughput. The latter involved re-aluminising the primary and formulating a procedure to ensure optimal alignment of the telescope mirrors. To this end, we developed the necessary hardware and techniques to ensure that such alignment is achieved and maintained, particularly following re-aluminising of the mirrors. In essence, the procedure involves: placing a Taylor Hobson Alignment Telescope on the mechanical rotation axis of the 74-inch (which we define to be the optical axis, since the Cassegrain instruments attach to the associated turntable), then adjusting the tip/tilt of the secondary mirror to get it onto that axis and, lastly, adjusting the tip/tilt of the primary mirror to eliminate coma. An eyepiece (or wavefront camera) is installed at the Cassegrain port for this final step since comatic star images indicate the need to tip/tilt the primary mirror to align it to the secondary. Tuning out any brightness gradients seen in an out-of-focus image of a bright star may also be used for feedback when adjusting the tip/tilt of the primary mirror to null coma.

  3. Why did the breast cancer lymph node status distribution improve in Denmark in the pre-mammography screening period of 1978-1994?

    International Nuclear Information System (INIS)

    Rostgaard, Klaus; Lynge, Elsebeth; Vaeth, Michael; Rootzen, Helle

    2010-01-01

    Background. Danish breast cancer patients diagnosed in 1978-1994 experienced a trend over time towards a more favourable distribution of lymph node status at time of diagnosis, which was not due to mammography screening. We investigated how this trend could be explained by patient characteristics at diagnosis: age (biological processes), calendar period (e.g. environmental changes), birth cohort (living conditions over a life time), post-menopausal status (a predictor of less favourable nodal status), and tumour diameter (a marker of detection time). Material and methods. The data set consisted of 22 955 patients aged 30-69 years at time of diagnosis with known lymph node status, known tumour diameter, known menopausal status, and clinically detected tumours, available from the Danish Breast Cancer Cooperative Group (DBCG). Age, period, cohort, menopausal status, and tumour diameter were used as predictors in generalised linear models with either node-positive status (at least one of the excised lymph nodes being tumour-positive) or severely node-positive status (at least half of the excised lymph nodes being tumour-positive) as outcomes. Lymph node status was assessed both empirically and estimated using an EM algorithm in order to reduce misclassification. Results and discussion. We found that the improved lymph node status distribution was most likely a period effect due to a combination of earlier detection of clinical tumours, explaining most of the trend in node-positive breast cancer and half of the trend in severely node-positive breast cancer, and some unknown factor affecting lymph node status but not necessarily other tumour characteristics

  4. Posterior breast cancer: Mammographic and ultrasonographic features

    Directory of Open Access Journals (Sweden)

    Janković Ana

    2013-01-01

    Full Text Available Background/Aim. Posterior breast cancers are located in the prepectoral region of the breast. Owing to this distinctive anatomical localization, physical examination and mammographic or ultrasonographic evaluation can be difficult. The purpose of the study was to assess possibilities of diagnostic mammography and breast ultrasonography in detection and differentiation of posterior breast cancers. Methods. The study included 40 women with palpable, histopathological confirmed posterior breast cancer. Mammographic and ultrasonographic features were defined according to Breast Imaging Reporting and Data System (BI-RADS lexicon. Results. Based on standard two-view mammography 87.5%, of the cases were classified as BI-RADS 4 and 5 categories, while after additional mammographic views all the cases were defined as BIRADS 4 and 5 categories. Among 96 mammographic descriptors, the most frequent were: spiculated mass (24.0%, architectural distortion (16.7%, clustered microcalcifications (12.6% and focal asymmetric density (12.6%. The differentiation of the spiculated mass was significantly associated with the possibility to visualize the lesion at two-view mammography (p = 0.009, without the association with lesion diameter (p = 0.083 or histopathological type (p = 0.055. Mammographic signs of invasive lobular carcinoma were significantly different from other histopathological types (architectural distortion, p = 0.003; focal asymmetric density, p = 0.019; association of four or five subtle signs of malignancy, p = 0.006. All cancers were detectable by ultrasonography. Mass lesions were found in 82.0% of the cases. Among 153 ultrasonographic descriptors, the most frequent were: irregular mass (15.7%, lobulated mass (7.2%, abnormal color Doppler signals (20.3%, posterior acoustic attenuation (18.3%. Ultrasonographic BI-RADS 4 and 5 categories were defined in 72.5% of the cases, without a significant difference among various histopathological types (p = 0

  5. Long-Term Exposure to Fine Particulate Matter and Breast Cancer Incidence in the Danish Nurse Cohort Study

    DEFF Research Database (Denmark)

    Andersen, Zorana J; Ravnskjaer, Line; Andersen, Klaus Kaae

    BACKGROUND: An association between air pollution and breast cancer risk has been suggested but evidence is sparse and inconclusive. METHODS: We included 22,877 female nurses from the Danish Nurse cohort who were recruited in 1993 or 1999, and followed them for incidence of breast cancer (N=1......,145) until 2013 in the Danish Cancer Register. We estimated annual mean concentrations of particulate matter with diameter nurses' residences since 1990 using an atmospheric chemistry transport model. We examined the association between...

  6. ORALLOY (93.15 235U) METAL ANNULI WITH BERYLLIUM CORE

    International Nuclear Information System (INIS)

    Bess, John D.; Montierth, Leland M.; Reed, Raymond L.; Mihalczo, John T.

    2010-01-01

    A variety of critical experiments were constructed of enriched uranium metal during the 1960s and 1970s at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. The purposes of these experiments included the evaluation of storage, casting, and handling limits for the Y-12 Plant and providing data for verification of calculation methods and cross-sections for nuclear criticality safety applications. These included solid cylinders of various diameters, annuli of various inner and outer diameters, two and three interacting cylinders of various diameters, and graphite and polyethylene reflected cylinders and annuli. Of the hundreds of delayed critical experiments, two were performed that consisted of uranium metal annuli with a solid beryllium metal core. The outer diameter of the annuli was approximately 13 or 15 inches with an inner diameter of 7 inches. The diameter of the core was approximately 7 inches. The critical height of the configurations was approximately 5 and 4 inches, respectively. The uranium annuli consisted of multiple stacked rings with diametral thicknesses of approximately 2 inches apiece and varying heights. The 15-inch experiment was performed on June 4, 1963, and the 13-inch experiment on July 12, 1963 by J. T. Mihalczo and R. G. Taylor (Ref. 1) with accompanying logbook. Both detailed and simplified model specifications are provided in this evaluation. Both of these fast-spectra experiments were determined to represent acceptable benchmarks. The calculated eigenvalues for both the detailed and simple models are within approximately 0.6% of the benchmark values, but significantly greater than 3s from the benchmark value because the uncertainty in the benchmark is very small: eff of ∼0.67%. Unreflected and unmoderated experiments with the same highly enriched uranium metal parts were performed at the Oak Ridge Critical Experiments Facility in the 1960s and are evaluated in HEU MET

  7. The Relationship amongst Intervertebral Disc Vertical Diameter, Lateral Foramen Diameter and Nerve Root Impingement in Lumbar Vertebra

    Directory of Open Access Journals (Sweden)

    Yusof MI

    2018-03-01

    Full Text Available Introduction: The vertical diameter of the foramen is dependent upon the vertical diameter of the corresponding intervertebral disc. A decrease in disc vertical diameter has direct anatomic consequences to the foraminal diameter and area available for the nerve root passing through it. This study is to establish the relationship amongst the intervertebral disc vertical diameter, lateral foramen diameters and nerve root compression in the lumbar vertebra. Materials and Methods: Measurements of the study parameters were performed using sagittal MRI images. The parameters studied were: intervertebral disc vertical diameter (DVD, foraminal vertical diameter (FVD, foraminal transverse diameter (FTD and nerve root diameter (NRD of both sides. The relationship between the measured parameters were then analyzed. Results: A total of 62 MRI images were available for this study. Statistical analysis showed moderate to strong correlation between DVD and FVD at all the lumbar levels except at left L23 and L5S1 and right L3L4 and L4L5. Correlation between DVD and FTD were not significant at all lumbar levels. Regression analysis showed that a decrease of 1mm of DVD was associated with 1.3, 1.7, 3.3, 3.3 and 1.3mm reduction of FVD at L1L2, L2L3, L3L4, L4L5 and L5S1 respectively. Conclusion: Reduction of DVD was associated with reduction of FVD. However, FVD was relatively wide for the nerve root even with complete loss of DVD. FTD was much narrower than the FVD making it more likely to cause nerve root compression at the exit foramina. These anatomical details should be given consideration in treating patients with lateral canal stenosis.

  8. Hybrid propulsion technology program. Volume 2: Technology definition package

    Science.gov (United States)

    Jensen, Gordon E.; Holzman, Allen L.; Leisch, Steven O.; Keilbach, Joseph; Parsley, Randy; Humphrey, John

    1989-01-01

    A concept design study was performed to configure two sizes of hybrid boosters; one which duplicates the advanced shuttle rocket motor vacuum thrust time curve and a smaller, quarter thrust level booster. Two sizes of hybrid boosters were configured for either pump-fed or pressure-fed oxygen feed systems. Performance analyses show improved payload capability relative to a solid propellant booster. Size optimization and fuel safety considerations resulted in a 4.57 m (180 inch) diameter large booster with an inert hydrocarbon fuel. The preferred diameter for the quarter thrust level booster is 2.53 m (96 inches). The demonstration plan would culminate with test firings of a 3.05 m (120 inch) diameter hybrid booster.

  9. Addendum 3 to CSAR 80-027, Use of calorimeter 109B for fissile material measurement

    International Nuclear Information System (INIS)

    Chiao, T.

    1994-01-01

    This modification to the Plutonium Finishing Plant (PFP) calorimeter system involves removing current calorimeter No. 3 from the water bath and replacing it with a calorimeter that can accommodate larger diameter items (an oversize can). The inside diameters of both the sample and the reference cells will be increased to 5.835 inches at the top opening and to 5.22 inches at the bottom, the 8 inch high measurement zone. This Addendum 3 to Criticality Safety Analysis Report 80-027 examines criticality safety during the use of the modified calorimeter (Calorimeter 109B) with enlarged cell tube diameters to assure that an adequate margin of subcriticality is maintained for all normal and contingency conditions

  10. Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips.

    Science.gov (United States)

    Schulz-Wendtland, R; Dankerl, P; Dilbat, G; Bani, M; Fasching, P A; Heusinger, K; Lux, M P; Loehberg, C R; Jud, S M; Rauh, C; Bayer, C M; Beckmann, M W; Wachter, D L; Uder, M; Meier-Meitinger, M; Brehm, B

    2015-01-01

    Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography.

  11. 77 FR 29905 - Sea Turtle Conservation; Shrimp and Summer Flounder Trawling Requirements

    Science.gov (United States)

    2012-05-21

    ... is typically constructed of steel rod with a minimum outside diameter of \\3/8\\ inch for the frame and... horizontal and vertical measurements of 36.5 and 48 inches, respectively, with a \\1/4\\-inch steel rod frame...) and 48 inches (121.9 cm), respectively. The frame must be constructed of steel rod with a minimum...

  12. Effects of Diameter on Initial Stiffness of P-Y Curves for Large-Diameter Piles in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Ibsen, Lars Bo; Augustesen, Anders Hust

    2010-01-01

    is developed for slender piles with diameters up to approximately 2.0 m. Hence, the method is not validated for piles with diameters of 4–6 m. The aim of the paper is to extend the p-y curve method to large-diameter non-slender piles in sand by considering the effects of the pile diameter on the soil-pile...... interaction. Hence, a modified expression for the p-y curves for statically loaded piles in sand is proposed in which the initial slope of the p-y curves depends on the depth below the soil surface, the pile diameter and the internal angle of friction. The evaluation is based on three-dimensional numerical...... analyses by means of the commercial program FLAC3D incorporating a Mohr-Coulomb failure criterion. The numerical model is validated with laboratory tests in a pressure tank at Aalborg University....

  13. 7 CFR 51.3067 - Serious damage.

    Science.gov (United States)

    2010-01-01

    ... serious damage: (a) Anthracnose when any spot exceeds the area of a circle one-fourth inch in diameter, or when more than 3 spots each of which exceeds the area of a circle three-sixteenths inch in diameter; (b) Cuts or other skin breaks when not healed and penetrating into the flesh of the fruit, or the aggregate...

  14. Production of exotic beams at the LBL 88-Inch Cyclotron by the ISOL method

    International Nuclear Information System (INIS)

    1990-04-01

    The Users of the LBL 88-Inch Cyclotron are preparing a proposal to produce exotic, i.e., radioactive beams. The facility will consist of a high-current 30 MeV cyclotron to generate the radioactive nuclei, an ECR source that can be coupled to different production targets, and the 88-Inch Cyclotron to accelerate the radioactive ions. Thus, the basic concept is that of the double cyclotron system pioneered at Louvain-la-Neuve, although the initial emphasis will be on producing a variety of light proton-rich beams at energies up to 10 MeV/A. At this workshop we wish to outline what is being planned, to invite comments and suggestions, and, especially, to encourage participation. We believe that this facility will be an important step toward establishing the scientific and technical basis for a National High Intensity Facility. This can be achieved through active participation by members of the radioactive beam (RB) community in (1) experiments with high quality radioactive beams of moderate intensity and, (2) R ampersand D on high beam-power targets and highly efficient ion sources. 5 refs., 4 figs

  15. Fission tracks diameters in glasses

    International Nuclear Information System (INIS)

    Garzon Ruiperez, L.; Veiguela, J.

    1974-01-01

    Standard glass microscope slides have been irradiated with fission fragments from the uranium. The etching track conditions have been the same for the series, having changed the etching time only for each specimen. For each glass, a minimum of 250 measurements of the tracks diameters have been made, the distributions of which are the bimodal type. Diameters-etching dependence with time is roughly lineal. Energy determinations have been made with the help of the diameters-energy relations. The calculated values agree very well with the know ones. (author) [es

  16. Alopecia neoplastica: An uncommon presentation of metastatic breast carcinoma

    Directory of Open Access Journals (Sweden)

    Felipe Ladeira de Oliveira

    2016-12-01

    Full Text Available Cutaneous metastasis may correspond to the initial clinical presentation of hidden internal malignancies. In patients presenting said neoplasia, clinical manifestations of breast cancer reaches 23.9%. Considering that neoplastic alopecia appears as an unusual pattern of the said metastasis, this report describes a case of such uncommon neoplastic alopecia which presents itself as a cutaneous metastasis of rapid progression in a patient with prior breast cancer history. We present a 47-year-old female patient reporting lesions at the scalp, and who was asymptomatic with a 1-year evolution. The patient reported prior breast cancer history and presence of lung metastasis, and was undergoing chemotherapy at the time of consultation. A dermatological evaluation showed only a nodular lesion with erythematous surface and a diameter measuring about 4 cm, firm in consistency, and immovable. She was routed to the Department of Dermatological Surgery, and the results from histopathology were consistent with a diagnosis of metastatic breast adenocarcinoma. Neoplastic alopecia appears as an unusual form of cutaneous metastasis which is predominantly described in association with breast cancer. The lesion’s clinical features play a crucial role at the differential diagnosis, as the presence of erythema could distinguish neoplastic alopecia from alopecia areata. The existence of cutaneous metastasis leads to unfavorable outcomes. As a conclusion, cutaneous evaluation of patients is essential for treating visceral metastases, since the forms of cutaneous metastasis are diverse and can also affect the scalp.

  17. Diameter-dependent coloration of silver nanowires

    International Nuclear Information System (INIS)

    Stewart, Mindy S; Qiu Chao; Jiang Chaoyang; Kattumenu, Ramesh; Singamaneni, Srikanth

    2011-01-01

    Silver nanowires were synthesized with a green method and characterized with microscopic and diffractometric methods. The correlation between the colors of the nanowires deposited on a solid substrate and their diameters was explored. Silver nanowires that appear similar in color in the optical micrographs have very similar diameters as determined by atomic force microscopy. We have summarized the diameter-dependent coloration for these silver nanowires. An optical interference model was applied to explain such correlation. In addition, microreflectance spectra were obtained from individual nanowires and the observed spectra can be explained with the optical interference theory. This work provides a cheap, quick and simple screening method for studying the diameter distribution of silver nanowires, as well as the diameter variations of individual silver nanowires, without complicated sample preparation.

  18. Correlation between PET/CT results and histological and immunohistochemical findings in breast carcinomas; Correlacao entre resultado do PET/CT e achados histologicos e imuno-histoquimicos em carcinomas mamarios

    Energy Technology Data Exchange (ETDEWEB)

    Bitencourt, Almir Galvao Vieira; Lima, Eduardo Nobrega Pereira; Chojniak, Rubens; Marques, Elvira Ferreira; Souza, Juliana Alves de; Graziano, Luciana; Andrade, Wesley Pereira; Osorio, Cynthia Aparecida Bueno de Toledo, E-mail: almirgvb@yahoo.com.br [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil)

    2014-03-15

    Objective: to correlate the results of {sup 18}F-fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) positron emission tomography/computed tomography (PET/CT) performed with a specific protocol for assessment of breasts with histological/immunohistochemical findings in breast carcinoma patients. Materials and methods: cross-sectional study with prospective data collection, where patients with biopsy-confirmed breast carcinomas were studied. The patients underwent PET/CT examination in prone position, with a specific protocol for assessment of breasts. PET/CT findings were compared with histological and immunohistochemical data. Results: the authors identified 59 malignant breast lesions in 50 patients. The maximum diameter of the lesions ranged from 6 to 80 mm (mean: 32.2 mm). Invasive ductal carcinoma was the most common histological type (n = 47; 79.7%). At PET/CT, 53 (89.8%) of the lesions demonstrated anomalous concentrations of {sup 18}F-FDG, with maximum SUV ranging from 0.8 to 23.1 (mean: 5.5). A statistically significant association was observed between higher values of maximum SUV and histological type, histological grade, molecular subtype, tumor diameter, mitotic index and Ki-67 expression. Conclusion: PET/CT performed with specific protocol for assessment of breasts has demonstrated good sensitivity and was associated with relevant histological/immunohistochemical factors related to aggressiveness and prognosis of breast carcinomas. (author)

  19. 50 CFR Figure 12 to Part 223 - Escape Opening & Cover Dimensions for 71-inch TED

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Escape Opening & Cover Dimensions for 71-inch TED 12 Figure 12 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE MARINE MAMMALS THREATENED MARINE AND ANADROMOUS SPECIES Pt. 223, Fig. 12 Figure 12 to...

  20. System geometry optimization for molecular breast tomosynthesis with focusing multi-pinhole collimators

    Science.gov (United States)

    van Roosmalen, Jarno; Beekman, Freek J.; Goorden, Marlies C.

    2018-01-01

    Imaging of 99mTc-labelled tracers is gaining popularity for detecting breast tumours. Recently, we proposed a novel design for molecular breast tomosynthesis (MBT) based on two sliding focusing multi-pinhole collimators that scan a modestly compressed breast. Simulation studies indicate that MBT has the potential to improve the tumour-to-background contrast-to-noise ratio significantly over state-of-the-art planar molecular breast imaging. The aim of the present paper is to optimize the collimator-detector geometry of MBT. Using analytical models, we first optimized sensitivity at different fixed system resolutions (ranging from 5 to 12 mm) by tuning the pinhole diameters and the distance between breast and detector for a whole series of automatically generated multi-pinhole designs. We evaluated both MBT with a conventional continuous crystal detector with 3.2 mm intrinsic resolution and with a pixelated detector with 1.6 mm pixels. Subsequently, full system simulations of a breast phantom containing several lesions were performed for the optimized geometry at each system resolution for both types of detector. From these simulations, we found that tumour-to-background contrast-to-noise ratio was highest for systems in the 7 mm-10 mm system resolution range over which it hardly varied. No significant differences between the two detector types were found.

  1. Isotachophoresis system having larger-diameter channels flowing into channels with reduced diameter and with selectable counter-flow

    Energy Technology Data Exchange (ETDEWEB)

    Mariella, Jr., Raymond P.

    2018-03-06

    An isotachophoresis system for separating a sample containing particles into discrete packets including a flow channel, the flow channel having a large diameter section and a small diameter section; a negative electrode operably connected to the flow channel; a positive electrode operably connected to the flow channel; a leading carrier fluid in the flow channel; a trailing carrier fluid in the flow channel; and a control for separating the particles in the sample into discrete packets using the leading carrier fluid, the trailing carrier fluid, the large diameter section, and the small diameter section.

  2. 7 CFR 51.320 - Diameter.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946... Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter...

  3. Benign breast disease, mammographic breast density, and the risk of breast cancer.

    Science.gov (United States)

    Tice, Jeffrey A; O'Meara, Ellen S; Weaver, Donald L; Vachon, Celine; Ballard-Barbash, Rachel; Kerlikowske, Karla

    2013-07-17

    Benign breast disease and high breast density are prevalent, strong risk factors for breast cancer. Women with both risk factors may be at very high risk. We included 42818 women participating in the Breast Cancer Surveillance Consortium who had no prior diagnosis of breast cancer and had undergone at least one benign breast biopsy and mammogram; 1359 women developed incident breast cancer in 6.1 years of follow-up (78.1% invasive, 21.9% ductal carcinoma in situ). We calculated hazard ratios (HRs) using Cox regression analysis. The referent group was women with nonproliferative changes and average density. All P values are two-sided. Benign breast disease and breast density were independently associated with breast cancer. The combination of atypical hyperplasia and very high density was uncommon (0.6% of biopsies) but was associated with the highest risk for breast cancer (HR = 5.34; 95% confidence interval [CI] = 3.52 to 8.09, P < .001). Proliferative disease without atypia (25.6% of biopsies) was associated with elevated risk that varied little across levels of density: average (HR = 1.37; 95% CI = 1.11 to 1.69, P = .003), high (HR = 2.02; 95% CI = 1.68 to 2.44, P < .001), or very high (HR = 2.05; 95% CI = 1.54 to 2.72, P < .001). Low breast density (4.5% of biopsies) was associated with low risk (HRs <1) for all benign pathology diagnoses. Women with high breast density and proliferative benign breast disease are at very high risk for future breast cancer. Women with low breast density are at low risk, regardless of their benign pathologic diagnosis.

  4. Remote target removal for the Oak Ridge 86-inch Cyclotron

    International Nuclear Information System (INIS)

    Walls, A.A.

    1982-01-01

    A remotely operated target remover has been plaed in operation at the 86-Inch Cyclotron located in Oak Ridge. The system provides for the remote removal of a target from inside the cyclotron, loading it into a cask, and the removal of the cask from the 1.5 m (5-ft) shielding walls. The remote system consists of multiple electrical and pneumatically operated equipment which is designed for controlled step-by-step operation, operated with an electrical control panel, and monitored by a television system. The target remover has reduced the radiation exposures to operating personnel at the facility and has increased the effective operating time. The system is fast, requires a minimum of skill to operate, and has demonstrated both reliability and durability

  5. [Fibrocystic breast disease--breast cancer sequence].

    Science.gov (United States)

    Habor, V; Habor, A; Copotoiu, C; Panţîru, A

    2010-01-01

    Fibrocystic breast disease has developed a major issue: the breast cancer sequence. Its involvement regarding the increse of breast cancer risk has 2 aspects: it may be either the marker of a prone tissue or a premalignant hystological deffect. Difficult differential diagnosis of benign proliferative breast lession and carcinoma led to the idea of sequency between the two: cancer does not initiate on normal mammary epithelia; it takes several proliferative stages for it to occur. In our series we analized a number of 677 breast surgical procedures where the pathologic examination reveals 115 cases (17%) of coexistence between cancer and fibrocystic breast disease. This aspect has proved to be related to earlier debut of breast cancer, suggesting that epithelial hyperplasia is a risk factor for breast cancer.

  6. First thin AC-coupled silicon strip sensors on 8-inch wafers

    Energy Technology Data Exchange (ETDEWEB)

    Bergauer, T., E-mail: thomas.bergauer@oeaw.ac.at [Institute of High Energy Physics of the Austrian Academy of Sciences, Nikolsdorfer Gasse 18, 1050 Wien (Vienna) (Austria); Dragicevic, M.; König, A. [Institute of High Energy Physics of the Austrian Academy of Sciences, Nikolsdorfer Gasse 18, 1050 Wien (Vienna) (Austria); Hacker, J.; Bartl, U. [Infineon Technologies Austria AG, Siemensstrasse 2, 9500 Villach (Austria)

    2016-09-11

    The Institute of High Energy Physics (HEPHY) in Vienna and the semiconductor manufacturer Infineon Technologies Austria AG developed a production process for planar AC-coupled silicon strip sensors manufactured on 200 μm thick 8-inch p-type wafers. In late 2015, the first wafers were delivered featuring the world's largest AC-coupled silicon strip sensors. Detailed electrical measurements were carried out at HEPHY, where single strip and global parameters were measured. Mechanical studies were conducted and the long-term behavior was investigated using a climate chamber. Furthermore, the electrical properties of various test structures were investigated to validate the quality of the manufacturing process.

  7. Elemental Water Impact Test: Phase 2 36-Inch Aluminum Tank Head

    Science.gov (United States)

    Vassilakos, Gregory J.

    2014-01-01

    Spacecraft are being designed based on LS-DYNA simulations of water landing impacts. The Elemental Water Impact Test (EWIT) series was undertaken to assess the accuracy of LS-DYNA water impact simulations. EWIT Phase 2 featured a 36-inch aluminum tank head. The tank head was outfitted with one accelerometer, twelve pressure transducers, three string potentiometers, and four strain gages. The tank head was dropped from heights of 1 foot and 2 feet. The focus of this report is the correlation of analytical models against test data. As a measure of prediction accuracy, peak responses from the baseline LS-DYNA model were compared to peak responses from the tests.

  8. The prognostic value of oncogenic antigen 519 (OA-519) expression and proliferative activity detected by antibody MIB-1 in node-negative breast cancer

    DEFF Research Database (Denmark)

    Jensen, V; Ladekarl, M; Holm-Nielsen, P

    1995-01-01

    The prognostic value of oncogenic antigen 519 (OA-519) expression and tumour proliferative activity was evaluated in a retrospective series of 118 patients with low-risk breast cancer. Low risk was defined as negative axillary nodes, tumour diameter histological evidence...... analysis, both the MIB-1 index and OA-519 expression were of independent prognostic value (2p breast cancer who might benefit from adjuvant therapy....

  9. Handbook for inventorying downed woody material

    Science.gov (United States)

    James K. Brown

    1974-01-01

    To facilitate debris management, procedures for inventorying downed woody material are presented. Instructions show how to estimate weights and volumes of downed woody material, fuel depth, and duff depth. Using the planar intersect technique, downed material is inventoried by 0- to 0.25-inch, 0.25- to 1-inch, and 1- to 3-inch diameter classes; and by 1-inch classes...

  10. Sector resection with and without radiotherapy in early breast cancer

    International Nuclear Information System (INIS)

    Holmberg, L.

    1989-01-01

    In 1982 a prospective, multicentre randomized trial of breast preserving surgery for invasive histopathological stage I breast cancer was started in the Uppsala-Oerebro health care region in Sweden. After identical preoperative investigation and surgical treatment, patients are randomly allocated to receive postoperative radiation with 54 Gy to the remaining breast for five weeks, or to serve as controls. The primary aim of the trial is to determine whether a standardized surgical technique aiming at local tumour radicality can reduce the rate of local recurrence to an acceptable level without postoperative radiotherapy. In December 1987 a second trial was initiated, with an almost identical design but including women with tumours mammographically 21-30 mm in diameter and with histopathologically negative nodes. The first trial is near the termination of patient accrual. Studies of the cosmetic result and of the psychosocial adjustment after breast conserving therapy as compared with mastectomy have been coupled to the trials. Among 263 patients who answered a questionnaire, 96.5% found the new appearance of the treated breast good or acceptable. The psychosocial adjustment was assessed in semi-structured interviews 4 and 13 months postoperatively in 99 women, 37 of whom underwent breast conserving surgery and the remainder modified radical mastectomy. There was a consistent but statistically non-significant tendency for the conservatively treated women to adjust better. Overall 5% of the women in the conservatively treated group and 22% of the mastectomized women are still suffering substantial psychosocial disturbance after 13 months. (orig.)

  11. Three-dimensional vascular mapping of the breast by using contrast-enhanced MRI: association of unilateral increased vascularity with ipsilateral breast cancer.

    Science.gov (United States)

    Orgüç, Şebnem; Başara, Işıl; Coşkun, Teoman; Pekindil, Gökhan

    2012-01-01

    We aimed to retrospectively compare three-dimensional vascular maps of both breasts obtained by dynamic magnetic resonance imaging (MRI) and determine the association of one-sided vascular prominence with ipsilateral breast cancer. MRI was performed using gadolinium in 194 cases. Two readers scored vascular density using maximum intensity projections (MIPs). Dynamic fat-saturated T1-weighted gradientecho MIPs were acquired. Two readers evaluated the MIPs, and vessels greater than 2 mm in diameter and longer than 3 cm were counted. The difference in vessel numbers detected in the two breasts determined the score. A total of 54 patients had malignant lesions (prevalence, 28%), including invasive ductal carcinoma (n=40), invasive mixed ductal-lobular carcinoma (n=5), invasive lobular carcinoma (n=3), ductal carcinoma in situ (n=3), mucinous carcinoma (n=1), medullary carcinoma (n=1), and leukemic metastasis (n=1). In 62 patients, there were benign lesions (fibroadenomas, fibrocysts), and four patients had inflammation (granulomatous mastitis in two patients, breast tuberculosis in two patients). There were 78 normal cases. When a difference of at least two vessels was scored as vascular asymmetry, the sensitivity, specificity, positive likelihood ratio (+LR), and negative (-LR) of unilaterally increased vascularity associated with ipsilateral malignancy were 69%, 92%, 8.72, and 0.34, respectively. When four infection and three post-operative cases with vascular asymmetry were excluded; prevalence, specificity, and +LR increased to 29%, 97%, and 22.8, respectively, with the same sensitivity and -LR. Differences in mean vascularity scores were evaluated with regard to tumor size. T1 and T2 tumors were not significantly different from each other. The mean score of T3 tumors differed significantly from T1 and T2 tumors. MRI vascular mapping is an effective method for determining breast tissue vascularization. Ipsilateral increased vascularity was commonly associated with

  12. Close relationship between diameters at 30cm height and at breast height (DBH Relações entre diametros a 30 cm de altura e à altura do peito (DAP

    Directory of Open Access Journals (Sweden)

    Christoph Gehring

    2008-01-01

    Full Text Available This paper proposes the establishment of a second diameter measuring standard at 30cm shoot extension ('diam30' as input variable for allometric biomass estimation of small and mid-sized plant shoots. This diameter standard is better suited than the diameter at breast height (DBH, i.e. diameter at 1.30m shoot extension for adequate characterization of plant dimensions in low bushy vegetation or in primary forest undergrowth. The relationships between both diameter standards are established based on a dataset of 8645 tree, liana and palm shoots in secondary and primary forests of central Amazonia (ranging from 1-150mm dbh. Dbh can be predicted from the diam(30 with high precision, the error introduced by diameter transformation is only 2-3% for trees and palms, and 5% for lianas. This is well acceptable for most field study purposes. Relationships deviate slightly from linearity and differ between growth forms. Relationships were markedly similar for different vegetation types (low secondary regrowth vs. primary forests, soils, and selected genera or species. This points to a general validity and applicability of diameter transformations for other field studies. This study provides researchers with a tool for the allometric estimation of biomass in low or structurally heterogeneous vegetation. Rather than applying a uniform diameter standard, the measuring position which best represents the respective plant can be decided on shoot-by-shoot. Plant diameters measured at 30cm height can be transformed to dbh for subsequent allometric biomass estimation. We recommend the use of these diameter transformations only for plants extending well beyond the theoretical minimum shoot length (i.e., >2m height. This study also prepares the ground for the comparability and compatability of future allometric equations specifically developed for small- to mid-sized vegetation components (i.e., bushes, undergrowth which are based on the diam(30 measuring standard

  13. Spectrophotometer-Integrating-Sphere System for Computing Solar Absorptance

    Science.gov (United States)

    Witte, William G., Jr.; Slemp, Wayne S.; Perry, John E., Jr.

    1991-01-01

    A commercially available ultraviolet, visible, near-infrared spectrophotometer was modified to utilize an 8-inch-diameter modified Edwards-type integrated sphere. Software was written so that the reflectance spectra could be used to obtain solar absorptance values of 1-inch-diameter specimens. A descriptions of the system, spectral reflectance, and software for calculation of solar absorptance from reflectance data are presented.

  14. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2005-04-01

    Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple cast-iron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of old cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1 (Program Management) and Task 2 (Establishment of Detailed Design Specifications) were completed previously. Task 3 (Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves) has progressed to installing prototype sleeves in test cast-iron pipe segments. Efforts in the current quarter continued to be focused on Tasks 4-8. Highly valuable lessons were learned from field tests of the 4-inch gas pipe repair robot in cast-iron pipe at Public Service Electric & Gas. (These field tests were conducted and reported previously.) Several design issues were identified which need to be implemented in both the small- and large-diameter repair

  15. Breast asymmetry and predisposition to breast cancer

    OpenAIRE

    Scutt, Diane; Lancaster, Gillian A; Manning, John T

    2006-01-01

    INTRODUCTION: It has been shown in our previous work that breast asymmetry is related to several of the known risk factors for breast cancer, and that patients with diagnosed breast cancer have more breast volume asymmetry, as measured from mammograms, than age-matched healthy women. METHODS: In the present study, we compared the breast asymmetry of women who were free of breast disease at time of mammography, but who had subsequently developed breast cancer, with that of age-matched healthy ...

  16. Full scale ambient water flow tests of a 10-inch emergency release coupling for LNG transfer

    NARCIS (Netherlands)

    Putte, L.J. van der; Webber, T.; Bokhorst, E. van; Revell, C.

    2016-01-01

    For LNG transfer in ship-to-ship and ship-to-shore configurations emergency release couplings (F.RC) in combination with loading arms and multi-composite hoses are applied In view of a demand for increasing transfer flow rates in offshore LNG applications a 10-inch ERC has been developed intended

  17. Appendiceal diameter: CT versus sonographic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orscheln, Emily S. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati, OH (United States); Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-03-15

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  18. Appendiceal diameter: CT versus sonographic measurements

    International Nuclear Information System (INIS)

    Orscheln, Emily S.; Trout, Andrew T.

    2016-01-01

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  19. SU-F-I-01: Normalized Mean Glandular Dose Values for Dedicated Breast CT Using Realistic Breast-Shaped Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A [Department of Radiology, Biomedical Engineering Graduate Group, University of California Davis, Sacramento, CA (United States); Boone, J [Departments of Radiology and Biomedical Engineering, Biomedical Engeering Graduate Group, University of California Davis, Sacramento, CA (United States)

    2016-06-15

    Purpose: To estimate normalized mean glandular dose values for dedicated breast CT (DgN-CT) using breast CT-derived phantoms and compare to estimations using cylindrical phantoms. Methods: Segmented breast CT (bCT) volume data sets (N=219) were used to measure effective diameter profiles and were grouped into quintiles by volume. The profiles were averaged within each quintile to represent the range of breast sizes found clinically. These profiles were then used to generate five voxelized computational phantoms (V1, V2, V3, V4, V5 for the small to large phantom sizes, respectively), and loaded into the MCNP6 lattice geometry to simulate normalized mean glandular dose coefficients (DgN-CT) using the system specifications of the Doheny-prototype bCT scanner in our laboratory. The DgN-CT coefficients derived from the bCT-derived breast-shaped phantoms were compared to those generated using a simpler cylindrical phantom using a constant volume, and the following constraints: (1) Length=1.5*radius; (2) radius determined at chest wall (Rcw), and (3) radius determined at the phantom center-of-mass (Rcm). Results: The change in Dg-NCT coefficients averaged across all phantom sizes, was - 0.5%, 19.8%, and 1.3%, for constraints 1–3, respectively. This suggests that the cylindrical assumption is a good approximation if the radius is taken at the breast center-of-mass, but using the radius at the chest wall results in an underestimation of the glandular dose. Conclusion: The DgN-CT coefficients for bCT-derived phantoms were compared against the assumption of a cylindrical phantom and proved to be essentially equivalent when the cylinder radius was set to r=1.5/L or Rcm. While this suggests that for dosimetry applications a patient’s breast can be approximated as a cylinder (if the correct radius is applied), this assumes a homogenous composition of breast tissue and the results may be different if the realistic heterogeneous distribution of glandular tissue is considered

  20. NO PLIF Imaging in the CUBRC 48 Inch Shock Tunnel

    Science.gov (United States)

    Jiang, N.; Bruzzese, J.; Patton, R.; Sutton J.; Lempert W.; Miller, J. D.; Meyer, T. R.; Parker, R.; Wadham, T.; Holden, M.; hide

    2011-01-01

    Nitric Oxide Planar Laser-Induced Fluorescence (NO PLIF) imaging is demonstrated at a 10 kHz repetition rate in the Calspan-University at Buffalo Research Center s (CUBRC) 48-inch Mach 9 hypervelocity shock tunnel using a pulse burst laser-based high frame rate imaging system. Sequences of up to ten images are obtained internal to a supersonic combustor model, located within the shock tunnel, during a single approx.10-millisecond duration run of the ground test facility. This represents over an order of magnitude improvement in data rate from previous PLIF-based diagnostic approaches. Comparison with a preliminary CFD simulation shows good overall qualitative agreement between the prediction of the mean NO density field and the observed PLIF image intensity, averaged over forty individual images obtained during several facility runs.

  1. ECR heavy-ion source for the LBL 88-inch cyclotron

    International Nuclear Information System (INIS)

    Clark, D.J.; Kalnins, J.G.; Lyneis, C.M.

    1983-03-01

    An Electron Cyclotron Resonance (ECR) heavy-ion source is under construction at the LBL 88-Inch Cyclotron. This source will produce very-high-charge-state heavy ions, such as 0 8 + and Ar 12 + , which will increase cyclotron energies by a factor of 2-4, up to A = 80. It is a two-stage source using room-temperature coils, a permanent-magnet sextupole, and a 6-9 GHz microwave system. Design features include adjustable first-to-second-stage plasma coupling, a variable second-stage mirror ratio, high-conductance radial pumping of the second stage, and a beam-diagnostic system. A remotely movable extraction electrode will optimize extraction efficiency. The project includes construction of a transport line and improvements to the cyclotron axial-injection system. The construction period is expected to be two years

  2. Force and work to shear green southern pine logs at slow speed

    Science.gov (United States)

    Peter Koch

    1971-01-01

    When logs of three diameter classes and two specific gravity classes were sheared with a 3/8-inch-thick knife travelling at 2 inches per minute, shearing force and work averaged greatest for dense 13.6-inch logs cut with a knife having a 45o sharpness angle (73,517 pounds; 49,838 foot-pounds). Force and work averaged at least 5.1-inch bolts of...

  3. Cytological Study of Breast Carcinoma Before and After Oncotherapy with Special Reference to Morphometry and Proliferative Activity.

    Science.gov (United States)

    Koley, Sananda; Chakrabarti, Srabani; Pathak, Swapan; Manna, Asim Kumar; Basu, Siddhartha

    2015-12-01

    Our study was done to assess the cytological changes due to oncotherapy in breast carcinoma especially on morphometry and proliferative activity. Cytological aspirates were collected from a total of 32 cases of invasive ductal carcinoma both before and after oncotherapy. Morphometry was done on the stained cytological smears to assess the different morphological parameters of cell dimension by using the ocular morphometer and the software AutoCAD 2007. Staining was done with Ki-67 and proliferating cell nuclear antigen (PCNA) as proliferative markers. Different morphological parameters were compared before and after oncotherapy by unpaired Student's t test. Statistically significant differences were found in morphometric parameters, e.g., mean nuclear diameter, mean nuclear area, mean cell diameter, and mean cell area, and in the expression of proliferative markers (Ki-67 and PCNA). Statistical analysis was done by obtaining p values. There are statistically significant differences between morphological parameter of breast carcinoma cells before and after oncotherapy.

  4. Combined use of 18F-FDG PET/CT and MRI for response monitoring of breast cancer during neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Pengel, Kenneth E.; Loo, Claudette E.; Koolen, Bas B.; Vogel, Wouter V.; Valdes Olmos, Renato A.; Wesseling, Jelle; Lips, Esther H.; Rutgers, Emiel J.T.; Vrancken Peeters, Marie Jeanne T.F.D.; Rodenhuis, Sjoerd; Gilhuijs, Kenneth G.A.

    2014-01-01

    To explore the potential complementary value of PET/CT and dynamic contrast-enhanced MRI in predicting pathological response to neoadjuvant chemotherapy (NAC) of breast cancer and the dependency on breast cancer subtype. We performed 18 F-FDG PET/CT and MRI examinations before and during NAC. The imaging features evaluated on both examinations included baseline and changes in 18 F-FDG maximum standardized uptake value (SUVmax) on PET/CT, and tumour morphology and contrast uptake kinetics on MRI. The outcome measure was a (near) pathological complete response ((near-)pCR) after surgery. Receiver operating characteristic curves with area under the curve (AUC) were used to evaluate the relationships between patient, tumour and imaging characteristics and tumour responses. Of 93 patients, 43 achieved a (near-)pCR. The responses varied among the different breast cancer subtypes. On univariate analysis the following variables were significantly associated with (near-)pCR: age (p = 0.033), breast cancer subtype (p < 0.001), relative change in SUVmax on PET/CT (p < 0.001) and relative change in largest tumour diameter on MRI (p < 0.001). The AUC for the relative reduction in SUVmax on PET/CT was 0.78 (95 % CI 0.68-0.88), and for the relative reduction in tumour diameter at late enhancement on MRI was 0.79 (95 % CI 0.70-0.89). The AUC increased to 0.90 (95 % CI 0.83-0.96) in the final multivariate model with PET/CT, MRI and breast cancer subtype combined (p = 0.012). PET/CT and MRI showed comparable value for monitoring response during NAC. Combined use of PET/CT and MRI had complementary potential. Research with more patients is required to further elucidate the dependency on breast cancer subtype. (orig.)

  5. Breast Pain

    Science.gov (United States)

    ... result in the development of breast cysts. Breast trauma, prior breast surgery or other factors localized to the breast can lead to breast pain. Breast pain may also start outside the breast — in the chest wall, muscles, joints or heart, for example — and ...

  6. Enhancing surface properties of breast implants by using electrospun silk fibroin.

    Science.gov (United States)

    Valencia-Lazcano, A A; Román-Doval, R; De La Cruz-Burelo, E; Millán-Casarrubias, E J; Rodríguez-Ortega, A

    2017-08-24

    In the present study, a new electrospun silk fibroin coating of silicone breast implants with improved biocompatibility and mechanical properties was obtained. Fibrous scaffolds were produced by electrospinning a solution containing silk fibroin, derived from Bombyx mori cocoons, and polyethylene oxide (PEO) to be used as a coating of breast implants. A randomly oriented structure of fibroin/PEO was electrospun on implants as assessed by SEM analysis, roughness measurements and ATR-FTIR spectroscopy. The scaffold showed 0.25 µm diameter fibres, 0.76 µm size superficial pores, arithmetic roughness of 0.632 ± 0.12 µm and texture aspect ratio of 0.893 ± 0.04. ATR-FTIR spectroscopy demonstrates the presence of PEO and fibroin in the coating. The mechanical characterisation of the implants before and after being coated with fibroin/PEO demonstrated that the fibroin/PEO scaffold contributes to the increase in the elastic modulus from 0.392 ± 0.02 to 0.560 ± 0.03 MPa and to a more elastic behaviour of the breast implants. Using the fibroin/PEO coating, human fibroblasts seeded on this matrix increased viability up to 30% compared to conventional breast implants. Electrospun silk fibroin could represent a clinically compatible, viable form to coat breast implants. Low cytotoxicity by the fibroin coating and its physico-chemical and mechanical properties may find application in improving breast implants biocompatibility. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017. © 2017 Wiley Periodicals, Inc.

  7. 29 CFR 1910.219 - Mechanical power-transmission apparatus.

    Science.gov (United States)

    2010-07-01

    ... dimensions specified in this paragraph shall apply to all guards, except horizontal overhead belts, rope... drives of twenty (20) inch centers or under shall be not less than one-fourth inch from the nearest... one-fourth (11/4) inches inside diameter, or larger. If made of metal shapes or bars, their section...

  8. Atypical presentation of a mucinous tumor of the breast as clustered microcalcifications

    International Nuclear Information System (INIS)

    Elorz, M.; Pina, L.; Bastarrika, G.; Bergaz, F.

    2001-01-01

    We present a case of mucinous breast carcinoma in which the only mammographic finding was the presence of a cluster of polymorphic microcalcifications with a maximum diameter of 4 mm. The histological study showed the lesion to correspond to a pure mucinous subtype. A review of the literature confirmed this to be a frankly atypical presentation, for which reason we consider it of interest to the radiologist. (Author) 11 refs

  9. Breast abscesses after breast conserving therapy for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Kazuhisa [National Kyoto Hospital (Japan)

    2001-09-01

    Breast abscess after breast conserving therapy is a rare complication and the study of this cause has not been reported. A retrospective review of 190 patients undergoing breast conserving therapy in our institution revealed 4 patients with breast abscess (mean age, 50.6 years; range, 47-57 years and median follow up 4 months; 1-11 months). Risk factors which were common to all patients were: fine needle aspiration (FNA), surgical treatment; wide excision, adjuvant therapy; oral administration of tamoxifen (TAM), radiation therapy (RT) to ipsilateral whole breast; total dose of 50 Gy and skin desquamation by RT; level I or II. Other important risk factors in 3 patients were repeated aspirations of seroma post operatively and 2 patients received chemotherapy; CAF. Cultures from one abscess grew staphylococcus aureus, one grew staphylococcus epidermidis, and two were sterile. Breast abscess may be caused by a variety of factors and it is often difficult to specify the cause. This suggests that careful observation will be necessary to determine the cause. (author)

  10. Breast abscesses after breast conserving therapy for breast cancer

    International Nuclear Information System (INIS)

    Fujiwara, Kazuhisa

    2001-01-01

    Breast abscess after breast conserving therapy is a rare complication and the study of this cause has not been reported. A retrospective review of 190 patients undergoing breast conserving therapy in our institution revealed 4 patients with breast abscess (mean age, 50.6 years; range, 47-57 years and median follow up 4 months; 1-11 months). Risk factors which were common to all patients were: fine needle aspiration (FNA), surgical treatment; wide excision, adjuvant therapy; oral administration of tamoxifen (TAM), radiation therapy (RT) to ipsilateral whole breast; total dose of 50 Gy and skin desquamation by RT; level I or II. Other important risk factors in 3 patients were repeated aspirations of seroma post operatively and 2 patients received chemotherapy; CAF. Cultures from one abscess grew staphylococcus aureus, one grew staphylococcus epidermidis, and two were sterile. Breast abscess may be caused by a variety of factors and it is often difficult to specify the cause. This suggests that careful observation will be necessary to determine the cause. (author)

  11. Spindle cell carcinoma of the breast as complex cystic lesion: a case report

    International Nuclear Information System (INIS)

    Kitada, Masahiro; Hayashi, Satoshi; Matsuda, Yoshinari; Ishibashi, Kei; Oikawa, Keisuke; Miyokawa, Naoyuki

    2014-01-01

    Spindle cell carcinoma of the breast is a rare tumor. This tumor can proliferate rapidly and cause cystic changes because of internal tissue necrosis. We evaluated a 54-year-old woman with right breast lump. Mammography showed a category four mass with a diameter of 2.5 cm. Ultrasonography (US) revealed a complex cystic lesion, and fine-needle aspiration (FNA) cytology demonstrated bloody fluid and malignant cells. Partial breast resection and sentinel lymph node biopsy were performed. Immunohistology revealed spindle cells with positive results for cytokeratin (AE1/AE3) and vimentin, partially positive results for s-100, and negative results for desmin and α-actin. The pathological stage was IIA, and biochemical characterization showed that the tumor was triple negative. Six courses of FEC-100 chemotherapy (5-fluorouracil 500 mg/m 2 , epirubicin 100 mg/m 2 , and cyclophosphamide 500 mg/m 2 ) were administered. Radiotherapy was performed. This case is discussed with reference to the literature

  12. Experiments with HEU (93.14 wt.%) metal annuli with internal graphite cylinder

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobo [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wehmann, Udo [Idaho National Lab. (INL), Idaho Falls, ID (United States); Mihalczo, John T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-04-01

    A variety of critical experiments were constructed of enriched uranium metal (oralloy ) during the 1960s and 1970s at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. The purposes of these experiments included the evaluation of storage, casting, and handling limits for the Y-12 Plant and providing data for verification of calculation methods and cross-sections for nuclear criticality safety applications. These included solid cylinders of various diameters, annuli of various inner and outer diameters, two and three interacting cylinders of various diameters, and graphite and polyethylene reflected cylinders and annuli. Of the hundreds of delayed critical experiments, only three experimental configurations are described here. They are internal graphite reflected metal uranium assemblies with three different diameter HEU annuli (15-9 inches, 15-7 inches and 13-7 inches). These experiments can be found in Reference 1 and in their associated logbook

  13. Self-detection and clinical breast examination: comparison of the two "classical" physical examination methods for the diagnosis of breast cancer.

    Science.gov (United States)

    Schwab, Fabienne Dominique; Huang, Dorothy Jane; Schmid, Seraina Margaretha; Schötzau, Andreas; Güth, Uwe

    2015-02-01

    This is the first comprehensive analysis comparing specific aspects of tumor detection between the two "traditional" breast cancer detection methods self-detection (SD) and clinical breast examination (CBE). a) Which method is better in detecting smaller tumors? Both methods showed similar mean tumor diameters (SD: 22.1 mm vs. CBE: 21.9 mm; p = 0.991). b) Different frequency distributions of tumor locations would indicate that certain locations in the breast are more difficult to palpate: comparison of both methods showed comparable results (p = 0.835). c) General differences in tumor sizes with regard to certain locations would be of importance because the patients and/or the physicians could be educated to pay particular attention to certain locations during physical examination, where larger tumors tend to be found: tumors located in the central region were with 25.0 mm significantly larger than those in the peripheral regions of the breast (superior: 21.6 mm, p = 0.001; inferior: 21.6 mm, p = 0.015; lateral: 21.9 mm, p = 0.002; medial (20.9 mm, p = 0.001). Tumor sizes within the four peripheral regions did not differ significantly. d) Patients whose tumors were found by CBE were older than those whose tumors were found by SD (67 years vs. 60 years, p < 0.001). annual CBE should be an integral part of general medical care in older women. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Inheritance of proliferative breast disease in breast cancer kindreds

    International Nuclear Information System (INIS)

    Skolnick, M.H.; Cannon-Albright, L.A.; Goldgar, D.E.; Ward, J.H.; Marshall, C.J.; Schumann, G.B.; Hogle, H.; McWhorter, W.P.; Wright, E.C.; Tran, T.D.; Bishop, D.T.; Kushner, J.P.; Eyre, H.J.

    1990-01-01

    Previous studies have emphasized that genetic susceptibility to breast cancer is rare and is expressed primarily as premenopausal breast cancer, bilateral breast cancer, or both. Proliferative breast disease (PBD) is a significant risk factor for the development of breast cancer and appears to be a precursor lesion. PBD and breast cancer were studied in 103 women from 20 kindreds that were selected for the presence of two first degree relatives with breast cancer and in 31 control women. Physical examination, screening mammography, and four-quadrant fine-needle breast aspirates were performed. Cytologic analysis of breast aspirates revealed PBD in 35% of clinically normal female first degree relatives of breast cancer cases and in 13% of controls. Genetic analysis suggests that genetic susceptibility causes both PBD and breast cancer in these kindreds. This study supports the hypothesis that this susceptibility is responsible for a considerable portion of breast cancer, including unilateral and postmenopausal breast cancer

  15. Individual-Tree Diameter Growth Models for Mixed Nothofagus Second Growth Forests in Southern Chile

    Directory of Open Access Journals (Sweden)

    Paulo C. Moreno

    2017-12-01

    Full Text Available Second growth forests of Nothofagus obliqua (roble, N. alpina (raulí, and N. dombeyi (coihue, known locally as RORACO, are among the most important native mixed forests in Chile. To improve the sustainable management of these forests, managers need adequate information and models regarding not only existing forest conditions, but their future states with varying alternative silvicultural activities. In this study, an individual-tree diameter growth model was developed for the full geographical distribution of the RORACO forest type. This was achieved by fitting a complete model by comparing two variable selection procedures: cross-validation (CV, and least absolute shrinkage and selection operator (LASSO regression. A small set of predictors successfully explained a large portion of the annual increment in diameter at breast height (DBH growth, particularly variables associated with competition at both the tree- and stand-level. Goodness-of-fit statistics for this final model showed an empirical coefficient of correlation (R2emp of 0.56, relative root mean square error of 44.49% and relative bias of −1.96% for annual DBH growth predictions, and R2emp of 0.98 and 0.97 for DBH projection at 6 and 12 years, respectively. This model constitutes a simple and useful tool to support management plans for these forest ecosystems.

  16. Investigation of Pipeline Concepts, Materials and Construction Techniques

    Science.gov (United States)

    1976-06-01

    Tite" Ethyl "Bell-Ring" Johns-Manville "Ring-Tite" Rehau "Mechan-O-Joint". Weights for 4 Inch, 6 Inch, and 8 inch diameter pipes are 1.86 LB/FT...415 Avenida Pico San Clemento, California 92672 C58 I Returned Reply Useful Used In By USPS Received Information Concept Rehau Plastiks, Incorporated

  17. 49 CFR 173.314 - Compressed gases in tank cars and multi-unit tank cars.

    Science.gov (United States)

    2010-10-01

    ... or secondary Division 2.1 (flammable gas) hazard. For single unit tank cars, interior pipes of... lading exceeding 1.52 mm (0.060 inch) diameter must be equipped with excess flow valves. For single unit... inches) glass fiber placed over 5.08 cm (2 inches) of ceramic fiber. Tank cars must have excess flow...

  18. Scintigraphic study of palpable breast nodes with 99m Tc-tetrofosmin

    International Nuclear Information System (INIS)

    Pellini, Marcos Pinto; Fonseca, Lea Mirian Barbosa da; Amarante Junior, Jose Luiz de Medeiros; Fabricio, Maria Ines Menescal

    1998-01-01

    In Brazil, breast carcinoma has the greater incidence among women. In 1996, about 31,210 new cases were diagnosed. The purpose of this study is to determine if 99m technetium-tetrofosmin preferentially concentrates within malignant palpable breast nodes, distinguishing them from the benign lumps. Fifth-four consecutive and unsolicited women, mean age 47.5 +- 10.7 years, with palpable nodes in breast, underwent breast scintigraphy with 99m technetium-tetrofosmin and excisional biopsy or fine needle puncture within interval eight weeks. Histopathologic studies demonstrated 13 cysts, 1 cyst with local inflammation, 11 fibroadenoma, 2 fibrodysplasias, 3 fibroadenomas with high cellularity, 1 fibrocystic change with local inflammation, 23 invasive intraductal carcinomas and 1 invasive lobular carcinoma. The nodes ranged from 10 to 100 mm in greater diameter. The scintigraphic study yielded 30 true-negative cases, 24 true-positives, no false-negative and 1 false-positive. This case was a fibrocystic lump with local inflammation. Two patients had metastases in axillary lymph nodes, well detected in scintigraphy. The statistic analysis showed: sensitivity, 100%; specificity, 96.8%; accuracy, 98.2%; negative predictive value, 100%; positive predictive value, 96.0%. Nonparametric tests of Fisher and Chi-square rejected the antithesis at a confidence interval of 99.9% (p 99m technetium-tetrofosmin preferentially concentrates in malignant palpable breast nodes and can help to distinguish them from the benign tumors with with very high accuracy. (author)

  19. Development and Evaluation of Models for the Relationship between Tree Height and Diameter at Breast Height for Chinese-Fir Plantations in Subtropical China.

    Science.gov (United States)

    Li, Yan-qiong; Deng, Xiang-wen; Huang, Zhi-hong; Xiang, Wen-hua; Yan, Wen-de; Lei, Pi-feng; Zhou, Xiao-lu; Peng, Chang-hui

    2015-01-01

    Tree diameter at breast height (dbh) and height are the most important variables used in forest inventory and management as well as forest carbon-stock estimation. In order to identify the key stand variables that influence the tree height-dbh relationship and to develop and validate a suit of models for predicting tree height, data from 5961 tree samples aged from 6 years to 53 years and collected from 80 Chinese-fir plantation plots were used to fit 39 models, including 33 nonlinear models and 6 linear models, were developed and evaluated into two groups. The results showed that composite models performed better in height estimate than one-independent-variable models. Nonlinear composite Model 34 and linear composite Model 6 were recommended for predicting tree height in Chinese fir plantations with a dbh range between 4 cm and 40 cm when the dbh data for each tree and the quadratic mean dbh of the stand (Dq) and mean height of the stand (Hm) were available. Moreover, Hm could be estimated by using the formula Hm = 11.707 × l n(Dq)-18.032. Clearly, Dq was the primary stand variable that influenced the height-dbh relationship. The parameters of the models varied according to stand age and site. The inappropriate application of provincial or regional height-dbh models for predicting small tree height at local scale may result in larger uncertainties. The method and the recommended models developed in this study were statistically reliable for applications in growth and yield estimation for even-aged Chinese-fir plantation in Huitong and Changsha. The models could be extended to other regions and to other tree species only after verification in subtropical China.

  20. WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A [Department of Radiology, Biomedical Engineering Graduate Group, University of California Davis, Sacramento, CA (United States); Boone, J [Departments of Radiology and Biomedical Engineering, University of California Davis, Sacramento, CA (United States)

    2016-06-15

    Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically. These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis

  1. WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

    International Nuclear Information System (INIS)

    Hernandez, A; Boone, J

    2016-01-01

    Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically. These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis

  2. Ultrasound Guided Needle Aspiration versus Surgical Drainage in the management of breast abscesses: a Ugandan experience

    Directory of Open Access Journals (Sweden)

    Chandika Alphonce B

    2012-01-01

    Full Text Available Abstract Background Despite breast abscess becoming less common in developed countries, it has remained one of the leading causes of morbidity in women in developing countries. A randomized controlled trial was conducted at Mulago hospital complex in Kampala Uganda to establish whether ultrasound guided needle aspiration is a feasible alternative treatment option for breast abscesses. Results A total of 65 females with breast abscess were analyzed, of these 33 patients were randomized into the ultrasound guided needle aspiration and 32 patients in the Incision and drainage arm. The mean age was 23.12, most of them were lactating (66.2%, primipararous (44.6% with peripheral abscesses (73.8% located in the upper lateral quadrant (56%.The mean breast size was 3.49 cm. The two groups were comparably in demographic characteristic and breast abscess size. Survival analysis showed no difference in breast abscess healing rate between the two groups (Log rank 0.24 df 1 and P = 0.63. Incision and drainage was found to be more costly than ultrasound guided aspiration (cost effective ratio of 2.85. Conclusion Ultrasound guided needle aspiration is therefore a feasible and cost effective treatment option for both lactating and non lactating breast abscesses with a diameter up to 5 cm by ultrasound in an immune competent patient

  3. Diameter 2 properties and convexity

    Czech Academy of Sciences Publication Activity Database

    Abrahamsen, T. A.; Hájek, Petr Pavel; Nygaard, O.; Talponen, J.; Troyanski, S.

    2016-01-01

    Roč. 232, č. 3 (2016), s. 227-242 ISSN 0039-3223 R&D Projects: GA ČR GA16-07378S Institutional support: RVO:67985840 Keywords : diameter 2 property * midpoint locally uniformly rotund * Daugavet property Subject RIV: BA - General Mathematics Impact factor: 0.535, year: 2016 https://www.impan.pl/pl/wydawnictwa/czasopisma-i-serie-wydawnicze/studia- mathematica /all/232/3/91534/diameter-2-properties-and-convexity

  4. Cosmetic outcome and curative effect of radiotherapy for early breast cancer after conservative surgery

    International Nuclear Information System (INIS)

    Ma Changuo; Ma Yuanyuan; Zhao Shuhong; Wang Hong

    2007-01-01

    Objective: To study the cosmetic outcome and curative effect of 6 MV X-ray tangential field radiotherapy for early stage breast cancer after conservative surgery. Methods: The eligible criteria were single tumor ≤3 cm in diameter, surgical margin negative and lymph node negative. The exclusive criteria were inflammatory carcinoma or male breast cancer. After conservative surgery, 42 patients with stage 0, I or II breast cancer were treated with conventional radiotherapy with a total dose of 50 Gy to the whole breast and 10 Gy boost to the tumor bed. The efficacy and the cosmetic outcome of radiotherapy were evaluated every 3 months for the first 2 years and every 6 months after that and every 12 months after 5 years. Results: The follow up time was 19-90 months (median 56 months). Two patients died of metastasis after 16 months and 36 months, which was diagnosed by CT scan. Excellent or good cosmetic outcome was > 93% at 36 months. The local control rate was 100%. The 1- and 3-year survival rates was 100% and 98%, respectively. Conclusions: Tangential field radiotherapy for early breast cancer after conservative surgery has a satisfied result in both tumor control and cosmetic outcome, which can definitely improve the life quality of the patients. (authors)

  5. Displacer Diameter Effect in Displacer Pulse Tube Refrigerator

    Science.gov (United States)

    Zhu, Shaowei

    2017-12-01

    Gas driving displacer pulse tube refrigerators are one of the work recovery type of pulse tube refrigerators whose theoretical efficiency is the same as Stirling refrigerators'. Its cooling power is from the displacement of the displacer. Displace diameter, rod diameter and pressure drop of the regenerator influence the displacement, which are investigated by numerical simulation. It is shown that the displacement ratio of the displacer over the piston is almost not affected by the displacer diameter at the same rod diameter ratio, or displacer with different diameters almost has the same performance.

  6. Breast Gangrene

    Directory of Open Access Journals (Sweden)

    Husasin Irfan

    2011-08-01

    Full Text Available Abstract Background Breast gangrene is rare in surgical practice. Gangrene of breast can be idiopathic or secondary to some causative factor. Antibiotics and debridement are used for management. Acute inflammatory infiltrate, severe necrosis of breast tissue, necrotizing arteritis, and venous thrombosis is observed on histopathology. The aim of was to study patients who had breast gangrene. Methods A prospective study of 10 patients who had breast gangrene over a period of 6 years were analyzed Results All the patients in the study group were female. Total of 10 patients were encountered who had breast gangrene. Six patients presented with breast gangrene on the right breast whereas four had on left breast. Out of 10 patients, three had breast abscess after teeth bite followed by gangrene, one had iatrogenic trauma by needle aspiration of erythematous area of breast under septic conditions. Four had history of application of belladonna on cutaneous breast abscess and had then gangrene. All were lactating female. Amongst the rest two were elderly, one of which was a diabetic who had gangrene of breast and had no application of belladonna. All except one had debridement under cover of broad spectrum antibiotics. Three patients had grafting to cover the raw area. Conclusion Breast gangrene occurs rarely. Etiology is variable and mutifactorial. Teeth bite while lactation and the iatrogenic trauma by needle aspiration of breast abscess under unsterlised conditions could be causative. Uncontrolled diabetes can be one more causative factor for the breast gangrene. Belladonna application as a topical agent could be inciting factor. Sometimes gangrene of breast can be idiopathic. Treatment is antibiotics and debridement.

  7. Techniques used by United Kingdom consultant plastic surgeons to select implant size for primary breast augmentation.

    Science.gov (United States)

    Holmes, W J M; Timmons, M J; Kauser, S

    2015-10-01

    Techniques used to estimate implant size for primary breast augmentation have evolved since the 1970s. Currently no consensus exists on the optimal method to select implant size for primary breast augmentation. In 2013 we asked United Kingdom consultant plastic surgeons who were full members of BAPRAS or BAAPS what was their technique for implant size selection for primary aesthetic breast augmentation. We also asked what was the range of implant sizes they commonly used. The answers to question one were grouped into four categories: experience, measurements, pre-operative external sizers and intra-operative sizers. The response rate was 46% (164/358). Overall, 95% (153/159) of all respondents performed some form of pre-operative assessment, the others relied on "experience" only. The most common technique for pre-operative assessment was by external sizers (74%). Measurements were used by 57% of respondents and 3% used intra-operative sizers only. A combination of measurements and sizers was used by 34% of respondents. The most common measurements were breast base (68%), breast tissue compliance (19%), breast height (15%), and chest diameter (9%). The median implant size commonly used in primary breast augmentation was 300cc. Pre-operative external sizers are the most common technique used by UK consultant plastic surgeons to select implant size for primary breast augmentation. We discuss the above findings in relation to the evolution of pre-operative planning techniques for breast augmentation. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. Mammographic Breast Density in Malaysian Women with Breast Cancer

    International Nuclear Information System (INIS)

    Noriah Jamal; Humairah Samad Cheung

    2016-01-01

    The objective of this study was to examine the mammographic breast density of women with breast cancer detected on voluntary mammographic screening at two selected screening centers in Malaysia. This was a retrospective study of Full-Field Digital Mammography (FFDM) images of 150 Malaysian women with biopsy-proven breast cancer. The study population comprised 73 Malays (37.7 %), 59 Chinese (39.3 %) and 18 Indians (12.0 %). The Tabar breast density Patterns (I - V) were used to evaluate mammographic breast density. Data were analyzed using descriptive statistics. The results were compared with findings from a similar study on a group of 668 women who did not have breast cancer. The results showed that 44.7 % of the study population had dense breasts (Patterns IV and V), 14.7 % had predominantly fatty breasts (Patterns II and III) while 40.7 % had Pattern I. The proportion of study population with dense breasts decreased with age. In conclusion, the proportion of women with dense breasts decreased with age. Majority of the women with cancer (44.7 %) had dense breasts of Tabar Patterns IV and V, which has been associated with increased risk of breast cancer detected by voluntary mammographic screening. The results support the notion that increased breast density is a risk factor of breast cancer. (author)

  9. Estimating Tree Height and Diameter at Breast Height (DBH from Digital Surface Models and Orthophotos Obtained with an Unmanned Aerial System for a Japanese Cypress (Chamaecyparis obtusa Forest

    Directory of Open Access Journals (Sweden)

    Kotaro Iizuka

    2017-12-01

    Full Text Available Methods for accurately measuring biophysical parameters are a key component for quantitative evaluation regarding to various forest applications. Conventional in situ measurements of these parameters take time and expense, encountering difficultness at locations with heterogeneous microtopography. To obtain precise biophysical data in such situations, we deployed an unmanned aerial system (UAS multirotor drone in a cypress forest in a mountainous area of Japan. The structure from motion (SfM method was used to construct a three-dimensional (3D model of the forest (tree structures from aerial photos. Tree height was estimated from the 3D model and compared to in situ ground data. We also analyzed the relationships between a biophysical parameter, diameter at breast height (DBH, of individual trees with canopy width and area measured from orthorectified images. Despite the constraints of ground exposure in a highly dense forest area, tree height was estimated at an accuracy of root mean square error = 1.712 m for observed tree heights ranging from 16 to 24 m. DBH was highly correlated with canopy width (R2 = 0.7786 and canopy area (R2 = 0.7923, where DBH ranged from 11 to 58 cm. The results of estimating forest parameters indicate that drone-based remote-sensing methods can be utilized to accurately analyze the spatial extent of forest structures.

  10. K+ ion source for the heavy ion induction linac system experiment ILSE

    International Nuclear Information System (INIS)

    Eylon, S.; Henestroza, E.; Chupp, W.W.; Yu, S.

    1993-01-01

    Low emittance singly charged potassium thermionic ion sources are being developed for the ILSE injector. The ILSE, now under study at LBL, will address the physics issues of particle beams in a heavy ion fusion driver scenario. The K + ion beam is emitted thermionically into a diode gap from alumino-silicate layers (zeolite) coated uniformly on a porous tungsten cup. The Injector diode design requires a large diameter (4 inches to 7 inches) source able to deliver high current (∼ 800 mA) low emittance (E n < .5 π mm-mr) beam. The SBTE (Single Beam Test Experiment) 120 keV gun was redesigned and modified with the aid of diode optics calculations using the EGUN code to enable the extraction of high currents of about 90 mA out of a one-inch diameter source. The authors report on the 1 inch source fabrication technique and performance, including total current and current density profile measurements using Faraday cups, emittance and phase space profile measurements using the double slit scanning technique, and life time measurements. Furthermore, they shall report on the extension of the fabricating technique to large diameter sources (up to 7 inches), measured ion emission performance, measured surface temperature uniformity and heating power considerations for large sources

  11. A comparison of R-22, R-134a, R-410a, and R-407c condensation performance in smooth and enhanced tubes: Part 1, Heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Eckels, S J; Tesene, B A

    1999-07-01

    Local and average heat transfer coefficients during condensation are reported for R-22, R-134a, R-410a, and R-407c in one smooth tube and three enhanced surface tubes. The test tubes included a 3/8 inch outer diameter smooth tube, a 3/8 inch outer diameter microfin tube, a 5/16 inch outer diameter microfin tube, and a 5/8 inch outer diameter microfin tube. The local and average heat transfer coefficients were measured over a mass flux range of 92,100 lb/ft{sup 2}{center_dot}h to 442,200 lb/ft{sup 2}{center_dot}h and at saturation temperatures of 104 F and 122 F. A comparison of the performance of the different refrigerants reveals that R-134a has the highest heat transfer performance followed by R-22 and R-410a, which have similar performances. In general, R-407c had the lowest performance of the refrigerants tested. The microfin tube more than doubles the heat transfer coefficient compared to the smooth tube for all refrigerants at the low mass fluxes, but only increases the heat transfer coefficients by 50% at the highest mass flux tested. The measured heat transfer coefficients are also compared with a number of correlations for condensation.

  12. Breast Tomosynthesis

    Science.gov (United States)

    ... in distinguishing non-cancerous breast conditions from breast cancers. Breast implants may also impede accurate mammogram readings because both ... view as much as possible without rupturing the implant. top of ... discuss breast cancer screening options with their doctors: Breast Density and ...

  13. An experimental investigation of forced convection burnout in high pressure water. Part IV, Large diameter tubes at about 1600 p.s.i

    International Nuclear Information System (INIS)

    Lee, D.H.

    1966-11-01

    The report presents 727 burnout results for tubes with uniform and non-uniform axial heat flux profiles. Most of the data are at 1600 p.s.i, although there are a limited number at 1250 and 1800 p.s.i. Tube diameters ranged from 0.5 to 1.8 inches. A new correlation for uniform flax data at these pressures is presented, having R.M.S. errors between 4 and 6%. A table of constant terms for this new uniform flux correlation is given, together with Macbeth's values for pressures of 560, 1000 and 2000 p.s.i. Experimental and predicted burnout powers for non-uniform axial heat fluxes are compared and the existing methods of prediction are found to be in error by up to 20%. A new method for predicting burnout with non-uniform axial heat flux is developed which correlates all published data to an R.M.S. error of 6.7%. (author)

  14. Breast MRI, digital mammography and breast tomosynthesis: comparison of three methods for early detection of breast cancer

    Directory of Open Access Journals (Sweden)

    Dragana Roganovic

    2015-11-01

    Full Text Available Breast cancer is the most common malignancy in women and early detection is important for its successful treatment. The aim of this study was to investigate the sensitivity and specificity of three methods for early detection of breast cancer: breast magnetic resonance imaging (MRI, digital mammography, and breast tomosynthesis in comparison to histopathology, as well as to investigate the intraindividual variability between these modalities.  We included 57 breast lesions, each detected by three diagnostic modalities: digital mammography, breast MRI, and breast tomosynthesis, and subsequently confirmed by histopathology. Breast Imaging-Reporting and Data System (BI-RADS was used for characterizing the lesions. One experienced radiologist interpreted all three diagnostic modalities. Twenty-nine of the breast lesions were malignant while 28 were benign. The sensitivity for digital mammography, breast MRI, and breast tomosynthesis, was 72.4%, 93.1%, and 100%, respectively; while the specificity was 46.4%, 60.7%, and 75%, respectively. Receiver operating characteristics (ROC curve analysis showed an overall diagnostic advantage of breast tomosynthesis over both breast MRI and digital mammography. The difference in performance between breast tomosynthesis and digital mammography was significant (p < 0.001, while the difference between breast tomosynthesis and breast MRI was not significant (p = 0.20. 

  15. Breast MRI, digital mammography and breast tomosynthesis: comparison of three methods for early detection of breast cancer.

    Science.gov (United States)

    Roganovic, Dragana; Djilas, Dragana; Vujnovic, Sasa; Pavic, Dag; Stojanov, Dragan

    2015-11-16

    Breast cancer is the most common malignancy in women and early detection is important for its successful treatment. The aim of this study was to investigate the sensitivity and specificity of three methods for early detection of breast cancer: breast magnetic resonance imaging (MRI), digital mammography, and breast tomosynthesis in comparison to histopathology, as well as to investigate the intraindividual variability between these modalities. We included 57 breast lesions, each detected by three diagnostic modalities: digital mammography, breast MRI, and breast tomosynthesis, and subsequently confirmed by histopathology. Breast Imaging-Reporting and Data System (BI-RADS) was used for characterizing the lesions. One experienced radiologist interpreted all three diagnostic modalities. Twenty-nine of the breast lesions were malignant while 28 were benign. The sensitivity for digital mammography, breast MRI, and breast tomosynthesis, was 72.4%, 93.1%, and 100%, respectively; while the specificity was 46.4%, 60.7%, and 75%, respectively. Receiver operating characteristics (ROC) curve analysis showed an overall diagnostic advantage of breast tomosynthesis over both breast MRI and digital mammography. The difference in performance between breast tomosynthesis and digital mammography was significant (p tomosynthesis and breast MRI was not significant (p=0.20).

  16. Grain Refinement of Steels through Solidification Modification

    Science.gov (United States)

    2017-09-14

    machined the tensile bar samples into 0.5 inch diameter tensile bars that met ASTM E8. Tensile testing occurred on a 450 kN hydraulic mechanical test...frame. The tests followed ASTM E8 guidelines and used gage marks for elongation measurement. An optical emission spectrometer (OES) analyzed the...emission spectrometer samples. Half-inch diameter tensile bars were turned on a Lathe in accordance with ASTM ES and tested on a hydraulic universal

  17. Influence of region of interest size and ultrasound lesion size on the performance of 2D shear wave elastography (SWE) in solid breast masses.

    Science.gov (United States)

    Skerl, K; Vinnicombe, S; Giannotti, E; Thomson, K; Evans, A

    2015-12-01

    To evaluate the influence of the region of interest (ROI) size and lesion diameter on the diagnostic performance of 2D shear wave elastography (SWE) of solid breast lesions. A study group of 206 consecutive patients (age range 21-92 years) with 210 solid breast lesions (70 benign, 140 malignant) who underwent core biopsy or surgical excision was evaluated. Lesions were divided into small (diameter <15 mm, n=112) and large lesions (diameter ≥15 mm, n=98). An ROI with a diameter of 1, 2, and 3 mm was positioned over the stiffest part of the lesion. The maximum elasticity (Emax), mean elasticity (Emean) and standard deviation (SD) for each ROI size were compared to the pathological outcome. Statistical analysis was undertaken using the chi-square test and receiver operating characteristic (ROC) analysis. The ROI size used has a significant impact on the performance of Emean and SD but not on Emax. Youden's indices show a correlation with the ROI size and lesion size: generally, the benign/malignant threshold is lower with increasing ROI size but higher with increasing lesion size. No single SWE parameter has superior performance. Lesion size and ROI size influence diagnostic performance. Copyright © 2015. Published by Elsevier Ltd.

  18. Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Jainil P., E-mail: jainil.shah@duke.edu [Department of Biomedical Engineering, Duke University, Durham, North Carolina 27705 and Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States); Mann, Steve D. [Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 and Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States); McKinley, Randolph L. [ZumaTek, Inc., Research Triangle Park, North Carolina 27709 (United States); Tornai, Martin P. [Department of Biomedical Engineering, Duke University, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 (United States); Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2015-08-15

    Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the

  19. Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

    International Nuclear Information System (INIS)

    Shah, Jainil P.; Mann, Steve D.; McKinley, Randolph L.; Tornai, Martin P.

    2015-01-01

    Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm"3 voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the

  20. Breast cancer screening in Korean woman with dense breast tissue

    International Nuclear Information System (INIS)

    Shin, Hee Jung; Ko, Eun Sook; Yi, Ann

    2015-01-01

    Asian women, including Korean, have a relatively higher incidence of dense breast tissue, compared with western women. Dense breast tissue has a lower sensitivity for the detection of breast cancer and a higher relative risk for breast cancer, compared with fatty breast tissue. Thus, there were limitations in the mammographic screening for women with dense breast tissue, and many studies for the supplemental screening methods. This review included appropriate screening methods for Korean women with dense breasts. We also reviewed the application and limitation of supplemental screening methods, including breast ultrasound, digital breast tomosynthesis, and breast magnetic resonance imaging; and furthermore investigated the guidelines, as well as the study results

  1. Breast cancer screening in Korean woman with dense breast tissue

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hee Jung [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Ko, Eun Sook [Dept. of Radiology, Sungkyunkwan University School of Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Yi, Ann [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul (Korea, Republic of)

    2015-11-15

    Asian women, including Korean, have a relatively higher incidence of dense breast tissue, compared with western women. Dense breast tissue has a lower sensitivity for the detection of breast cancer and a higher relative risk for breast cancer, compared with fatty breast tissue. Thus, there were limitations in the mammographic screening for women with dense breast tissue, and many studies for the supplemental screening methods. This review included appropriate screening methods for Korean women with dense breasts. We also reviewed the application and limitation of supplemental screening methods, including breast ultrasound, digital breast tomosynthesis, and breast magnetic resonance imaging; and furthermore investigated the guidelines, as well as the study results.

  2. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  3. A patient with angiosarcoma of the breast after breast-conserving surgery and radiotherapy for breast cancer

    International Nuclear Information System (INIS)

    Yasuoka, Rie; Mitsuo, Manabu; Hanioka, Keisuke

    2014-01-01

    An 89-year-old woman underwent breast-conserving surgery and axillary lymph node dissection (right AC region, T2N0M0, stage 2A, invasive ductal carcinoma, papillotubular type) for right breast cancer in February 2005. She received postoperative radiotherapy to the residual breast. She then developed marked edema of the right arm and right breast. A mass developed in the right breast in March 2011 and March 2013. This was originally suspected to be an ipsilateral breast recurrence of the cancer, but turned to be angiosarcoma after developing recurrent mass in March 2013, which histopathology was proved to be showed angiosarcoma of the breast. The patient subsequently had repeated intradermal and subcutaneous metastases and recurrence. She is currently receiving chemotherapy with docetaxel (30 mg/m 2 biweekly). This interesting case of angiosarcoma of the breast after breast-conserving surgery for breast cancer is reported. (author)

  4. Diameter effect on critical heat flux

    International Nuclear Information System (INIS)

    Tanase, A.; Cheng, S.C.; Groeneveld, D.C.; Shan, J.Q.

    2009-01-01

    The critical heat flux look-up table (CHF LUT) is widely used to predict CHF for various applications, including design and safety analysis of nuclear reactors. Using the CHF LUT for round tubes having inside diameters different from the reference 8 mm involves conversion of CHF to 8 mm. Different authors [Becker, K.M., 1965. An Analytical and Experimental Study of Burnout Conditions in Vertical Round Ducts, Aktiebolaget Atomenergie Report AE 177, Sweden; Boltenko, E.A., et al., 1989. Effect of tube diameter on CHF at various two phase flow regimes, Report IPE-1989; Biasi, L., Clerici, G.C., Garriba, S., Sala, R., Tozzi, A., 1967. Studies on Burnout, Part 3, Energia Nucleare, vol. 14, pp. 530-536; Groeneveld, D.C., Cheng, S.C., Doan, T., 1986. AECL-UO critical heat flux look-up table. Heat Transfer Eng., 7, 46-62; Groeneveld et al., 1996; Hall, D.D., Mudawar, I., 2000. Critical heat flux for water flow in tubes - II subcooled CHF correlations. Int. J. Heat Mass Transfer, 43, 2605-2640; Wong, W.C., 1996. Effect of tube diameter on critical heat flux, MaSC dissertation, Ottawa Carleton Institute for Mechanical and Aeronautical Engineering, University of Ottawa] have proposed several types of correlations or factors to describe the diameter effect on CHF. The present work describes the derivation of new diameter correction factor and compares it with several existing prediction methods

  5. BREAST RECONSTRUCTIONS AFTER BREAST CANCER TREATING

    OpenAIRE

    Erik Vrabič

    2018-01-01

    Background. Breasts are an important symbol of physical beauty, feminity, mothering and sexual desire through the entire history of mankind. Lost of the whole or part of the breast is functional and aesthetic disturbance for woman. It is understandable, that the woman, who is concerned over breast loss, is as appropriate as another person´s concern over the loss of a limb or other body part. Before the 1960, breast reconstruction was considered as a dangerous procedure and it was almost prohi...

  6. SPECIFIC CHARACTERISTICS OF BRAIN METASTASIZING IN PATIENTS WITH LUMINAL SUBTYPE OF BREAST CANCER

    Directory of Open Access Journals (Sweden)

    A. S. Balkanov

    2016-01-01

    Full Text Available Background: More than half of female patients with breast cancer are diagnosed with a  luminal subtype of the disease; however, specific characteristics of its metastases to the brain have been not well studied, unlike those of HER2 positive and triple negative subtypes. Aim: A  comparative analysis of characteristics of metastatic brain lesions in patients with luminal breast cancer. Materials and methods: The time from surgery for breast cancer to the first recurrence and to metastatic brain lesions (assessed by contrast-enhanced MRI imaging was measured in 41 patients with luminal subtype of breast cancer (median age, 49.5±9.6  years, depending on a  diameter of the primary tumor and numbers of involved axillary lymph nodes. Results: The time interval to occurrence of brain metastases in luminal subtype of breast cancer is not associated with the size of the tumor. If≥4  axillary lymph nodes are involved (N2–3, brain metastases are identified much earlier (p<0.05 than in patients with N0–1 (34.5±23.9 months and 62.7±50 months, respectively. Neither the size nor the involvement of axillary lymph nodes has any impact on the rates of metastatic lesion to the brain during the first recurrence. Conclusion: Brain metastases occur at a much shorter time in those patients of luminal subtype of breast cancer who have metastases in≥4  axillary lymph nodes. Brain metastases develop in 50% of patients with the first recurrence of the luminal subtype of breast cancer.

  7. Abnormal splenic artery diameter/hepatic artery diameter ratio in cirrhosis-induced portal hypertension

    Science.gov (United States)

    Zeng, Dao-Bing; Dai, Chuan-Zhou; Lu, Shi-Chun; He, Ning; Wang, Wei; Li, Hong-Jun

    2013-01-01

    AIM: To determine an optimal cutoff value for abnormal splenic artery diameter/proper hepatic artery diameter (S/P) ratio in cirrhosis-induced portal hypertension. METHODS: Patients with cirrhosis and portal hypertension (n = 770) and healthy volunteers (n = 31) underwent volumetric computed tomography three-dimensional vascular reconstruction to measure the internal diameters of the splenic artery and proper hepatic artery to calculate the S/P ratio. The cutoff value for abnormal S/P ratio was determined using receiver operating characteristic curve analysis, and the prevalence of abnormal S/P ratio and associations between abnormal S/P ratio and major complications of portal hypertension were studied using logistic regression. RESULTS: The receiver operating characteristic analysis showed that the cutoff points for abnormal splenic artery internal diameter and S/P ratio were > 5.19 mm and > 1.40, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value were 74.2%, 45.2%, 97.1%, and 6.6%, respectively. The prevalence of an abnormal S/P ratio in the patients with cirrhosis and portal hypertension was 83.4%. Patients with a higher S/P ratio had a lower risk of developing ascites [odds ratio (OR) = 0.708, 95%CI: 0.508-0.986, P = 0.041] and a higher risk of developing esophageal and gastric varices (OR = 1.483, 95%CI: 1.010-2.175, P = 0.044) and forming collateral circulation (OR = 1.518, 95%CI: 1.033-2.230, P = 0.034). After splenectomy, the portal venous pressure and maximum and mean portal venous flow velocities were reduced, while the flow rate and maximum and minimum flow velocities of the hepatic artery were increased (P portal hypertension, and it can be used as an important marker of splanchnic hemodynamic disturbances. PMID:23483462

  8. Database and prediction model for CANDU pressure tube diameter

    Energy Technology Data Exchange (ETDEWEB)

    Jung, J.Y.; Park, J.H. [Korea Atomic Energy Research Inst., Daejeon (Korea, Republic of)

    2014-07-01

    The pressure tube (PT) diameter is basic data in evaluating the CCP (critical channel power) of a CANDU reactor. Since the CCP affects the operational margin directly, an accurate prediction of the PT diameter is important to assess the operational margin. However, the PT diameter increases by creep owing to the effects of irradiation by neutron flux, stress, and reactor operating temperatures during the plant service period. Thus, it has been necessary to collect the measured data of the PT diameter and establish a database (DB) and develop a prediction model of PT diameter. Accordingly, in this study, a DB for the measured PT diameter data was established and a neural network (NN) based diameter prediction model was developed. The established DB included not only the measured diameter data but also operating conditions such as the temperature, pressure, flux, and effective full power date. The currently developed NN based diameter prediction model considers only extrinsic variables such as the operating conditions, and will be enhanced to consider the effect of intrinsic variables such as the micro-structure of the PT material. (author)

  9. Quantitative DCE-MRI for prediction of pathological complete response following neoadjuvant treatment for locally advanced breast cancer: the impact of breast cancer subtypes on the diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Drisis, Stylianos; Stathopoulos, Konstantinos; Chao, Shih-Li; Lemort, Marc [Institute Jules Bordet, Radiology Department, Brussels (Belgium); Metens, Thierry [Erasme University Hospital, Radiology Department, Brussels (Belgium); Ignatiadis, Michael [Institute Jules Bordet, Oncology Department, Brussels (Belgium)

    2016-05-15

    To assess whether DCE-MRI pharmacokinetic (PK) parameters obtained before and during chemotherapy can predict pathological complete response (pCR) differently for different breast cancer groups. Eighty-four patients who received neoadjuvant chemotherapy for locally advanced breast cancer were retrospectively included. All patients underwent two DCE-MRI examinations, one before (EX1) and one during treatment (EX2). Tumours were classified into different breast cancer groups, namely triple negative (TNBC), HER2+ and ER+/HER2-, and compared with the whole population (WP). PK parameters Ktrans and Ve were extracted using a two-compartment Tofts model. At EX1, Ktrans predicted pCR for WP and TNBC. At EX2, maximum diameter (Dmax) predicted pCR for WP and ER+/HER2-. Both PK parameters predicted pCR in WP and TNBC and only Ktrans for the HER2+. pCR was predicted from relative difference (EX1 - EX2)/EX1 of Dmax and both PK parameters in the WP group and only for Ve in the TNBC group. No PK parameter could predict response for ER+/HER-. ROC comparison between WP and breast cancer groups showed higher but not statistically significant values for TNBC for the prediction of pCR Quantitative DCE-MRI can better predict pCR after neoadjuvant treatment for TNBC but not for the ER+/HER2- group. (orig.)

  10. Leak in spiral weld in a 16 inches gas pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Fazzini, Pablo G; Bona, Jeremias de [GIE S.A., Mar del Plata (Argentina); Otegui, Jose L [University of Mar del Plata (Argentina)

    2009-07-01

    This paper discusses a failure analysis after a leak in the spiral weld of a 16 inches natural gas pipeline, in service since 1974. The leak was the result of the coalescence of two different defects, on each surface of the pipe wall, located in the center of the inner cord of the helical DSAW weld. Fractographic and metallographic studies revealed that the leak was a combination of three conditions. During fabrication of the pipe, segregation in grain boundary grouped in mid weld. During service, these segregations underwent a process of selective galvanic corrosion. One of these volumetric defects coincided with a tubular pore in the outer weld. Pigging of the pipeline in 2005 for cleaning likely contributed to the increase of the leak flow, when eliminating corrosion product plugs. Although these defects are likely to repeat, fracture mechanics shows that a defect of this type is unlikely to cause a blowout. (author)

  11. Radiation effects testing at the 88-Inch Cyclotron at LBNL

    International Nuclear Information System (INIS)

    McMahan, Margaret A.; Koga, Rokotura

    2002-01-01

    The effects of ionizing particles on sensitive microelectronics is an important component of the design of systems as diverse as satellites and space probes, detectors for high energy physics experiments and even internet server farms. Understanding the effects of radiation on human cells is an equally important endeavor directed towards future manned missions in space and towards cancer therapy. At the 88-Inch Cyclotron at the Berkeley Laboratory, facilities are available for radiation effects testing (RET) with heavy ions and with protons. The techniques for doing these measurements and the advantages of using a cyclotron will be discussed, and the Cyclotron facilities will be compared with other facilities worldwide. RET of the same part at several facilities of varying beam energy can provide tests of the simple models used in this field and elucidate the relative importance of atomic and nuclear effects. The results and implications of such measurements will be discussed

  12. [MRI findings and pathological features of occult breast cancer].

    Science.gov (United States)

    Zhang, J J; Yang, X T; Du, X S; Zhang, J X; Hou, L N; Niu, J L

    2018-01-23

    Objective: To investigate the magnetic resonance imaging (MRI) findings and clinicopathological features of primary lesions in patients with occult breast cancer (OBC). Methods: The imaging reports from the Breast Imaging Reporting and Data System in 2013 were retrospectively analyzed to investigate the morphology and the time signal intensity curve (TIC) of breast lesions in patients with OBC. The clinical and pathological characteristics of these patients were also included. Results: A total of 34 patients were enrolled. Among these patients, 24 patients underwent modified radical mastectomy and 18 of them had primary breast carcinoma in pathological sections. MRI detected 17 cases of primary lesions, including six masse lesions with a diameter of 0.6-1.2 cm (average 0.9 cm), and 11 non-mass lesions with four linear distributions, three segmental distributions, three focal distributions, and one regions distribution. Five patients had TIC typeⅠprimary lesions, ten had TIC type Ⅱ primary lesions, and two had TIC type Ⅲ primary lesions. Among all 34 cases, 23 of them had complete results of immunohistochemistry: 11 estrogen receptor (ER) positive lesions (47.8%), tenprogesterone receptor (PR) positive lesions (43.5%), seven human epidermal growth factor receptor 2 (HER-2) positive lesions (30.4%), and 20high expression(>14%) of Ki-67 (87.0%). The proportion of type luminal A was 4.3%, type luminal B was 43.5%, triple negative breast cancer (TNBC) was 30.4%, and HER-2 over expression accounted for 21.7%. Conclusions: The primary lesions of OBC usually manifested as small mass lesions, or focal, linear or segmental distribution of non-mass lesions. The positive rate of ER and PR was low, but the positive rate of HER-2 and the proliferation index of Ki-67 was high. Type luminal B is the most common molecular subtype.

  13. Breast-Lesion Characterization using Textural Features of Quantitative Ultrasound Parametric Maps.

    Science.gov (United States)

    Sadeghi-Naini, Ali; Suraweera, Harini; Tran, William Tyler; Hadizad, Farnoosh; Bruni, Giancarlo; Rastegar, Rashin Fallah; Curpen, Belinda; Czarnota, Gregory J

    2017-10-20

    This study evaluated, for the first time, the efficacy of quantitative ultrasound (QUS) spectral parametric maps in conjunction with texture-analysis techniques to differentiate non-invasively benign versus malignant breast lesions. Ultrasound B-mode images and radiofrequency data were acquired from 78 patients with suspicious breast lesions. QUS spectral-analysis techniques were performed on radiofrequency data to generate parametric maps of mid-band fit, spectral slope, spectral intercept, spacing among scatterers, average scatterer diameter, and average acoustic concentration. Texture-analysis techniques were applied to determine imaging biomarkers consisting of mean, contrast, correlation, energy and homogeneity features of parametric maps. These biomarkers were utilized to classify benign versus malignant lesions with leave-one-patient-out cross-validation. Results were compared to histopathology findings from biopsy specimens and radiology reports on MR images to evaluate the accuracy of technique. Among the biomarkers investigated, one mean-value parameter and 14 textural features demonstrated statistically significant differences (p feature selection method could classify the legions with a sensitivity of 96%, a specificity of 84%, and an AUC of 0.97. Findings from this study pave the way towards adapting novel QUS-based frameworks for breast cancer screening and rapid diagnosis in clinic.

  14. Characterization of breast tissue using energy-dispersive X-ray diffraction computed tomography

    International Nuclear Information System (INIS)

    Pani, S.; Cook, E.J.; Horrocks, J.A.; Jones, J.L.; Speller, R.D.

    2010-01-01

    A method for sample characterization using energy-dispersive X-ray diffraction computed tomography (EDXRDCT) is presented. The procedures for extracting diffraction patterns from the data and the corrections applied are discussed. The procedures were applied to the characterization of breast tissue samples, 6 mm in diameter. Comparison with histological sections of the samples confirmed the possibility of grouping the patterns into five families, corresponding to adipose tissue, fibrosis, poorly differentiated cancer, well differentiated cancer and benign tumour.

  15. Invasive lobular carcinoma of the breast: MRI pathological correlation following bilateral total mastectomy

    International Nuclear Information System (INIS)

    Stivalet, Aude; Pigneur, Frederic; Luciani, Alain

    2012-01-01

    Background: Invasive lobular carcinoma (ILC) is more often multifocal and bilateral than invasive ductal carcinoma. MRI is usually recommended for detection of all ILC sites. The performance of known diagnostic breast MRI criteria for ILC characterization has not been evaluated to date using bilateral mastectomy specimens as gold standard. Purpose: To determine the value of BI-RADS 2006 MRI criteria for ILC detection and characterization, using pathological examination of bilateral mastectomy specimens as the reference standard. Material and Methods: Between 2004 and 2007, we retrospectively included all patients with pathologically documented ILC referred to our institution for bilateral mastectomy and preoperative bilateral breast MRI. The location, diameter, and characteristics (BI-RADS) of all lesions were compared with pathological findings. The sensitivity and positive predictive value of bilateral breast MRI for the diagnosis of ILC were calculated. Association of MRI BI-RADS categorical variables and characterization of ILC were assessed (Fisher exact test). Results: Among 360 patients treated for ILC in 2004-2007, 15 patients qualified for this study. Thirty-one ILC foci were found on pathological examination (30 ipsilateral and 1 contralateral tumor; mean diameter 23 mm; range 2-60 mm) and all were identified on MRI, with 90% of masses and 10% non-mass-like enhancements; MRI features significantly associated with ILC included absence of smooth margins (P = 0.02) and rim-shaped enhancement (P = 0.039). Enhancement kinetics of the 31 foci were evenly distributed among wash-out, plateau, and persistent profiles. Eleven additional lesions were seen on MRI, mainly corresponding to fibrocystic disease; 91% presented as masses and 9% had a wash-out profile. Conclusion: Based on the 2006 BI-RADS criteria, breast MRI shows a high sensitivity for ILC detection, at the expense of a 26% false-positive rate, suggesting that a pathological proof by US- or MR

  16. Invasive lobular carcinoma of the breast: MRI pathological correlation following bilateral total mastectomy

    Energy Technology Data Exchange (ETDEWEB)

    Stivalet, Aude; Pigneur, Frederic (AP-HP, Groupe Henri Mondor Albert Chenevier, Imagerie Medicale, Creteil (France)); Luciani, Alain (AP-HP, Groupe Henri Mondor Albert Chenevier, Imagerie Medicale, Creteil (France); INSERM Unite U 955, Equipe 17, Univ. Paris Est Creteil, Creteil (France)), email: alain.luciani@hmn.aphp.fr (and others)

    2012-05-15

    Background: Invasive lobular carcinoma (ILC) is more often multifocal and bilateral than invasive ductal carcinoma. MRI is usually recommended for detection of all ILC sites. The performance of known diagnostic breast MRI criteria for ILC characterization has not been evaluated to date using bilateral mastectomy specimens as gold standard. Purpose: To determine the value of BI-RADS 2006 MRI criteria for ILC detection and characterization, using pathological examination of bilateral mastectomy specimens as the reference standard. Material and Methods: Between 2004 and 2007, we retrospectively included all patients with pathologically documented ILC referred to our institution for bilateral mastectomy and preoperative bilateral breast MRI. The location, diameter, and characteristics (BI-RADS) of all lesions were compared with pathological findings. The sensitivity and positive predictive value of bilateral breast MRI for the diagnosis of ILC were calculated. Association of MRI BI-RADS categorical variables and characterization of ILC were assessed (Fisher exact test). Results: Among 360 patients treated for ILC in 2004-2007, 15 patients qualified for this study. Thirty-one ILC foci were found on pathological examination (30 ipsilateral and 1 contralateral tumor; mean diameter 23 mm; range 2-60 mm) and all were identified on MRI, with 90% of masses and 10% non-mass-like enhancements; MRI features significantly associated with ILC included absence of smooth margins (P = 0.02) and rim-shaped enhancement (P = 0.039). Enhancement kinetics of the 31 foci were evenly distributed among wash-out, plateau, and persistent profiles. Eleven additional lesions were seen on MRI, mainly corresponding to fibrocystic disease; 91% presented as masses and 9% had a wash-out profile. Conclusion: Based on the 2006 BI-RADS criteria, breast MRI shows a high sensitivity for ILC detection, at the expense of a 26% false-positive rate, suggesting that a pathological proof by US- or MR

  17. Endocrine determinants of breast density and breast cancer

    NARCIS (Netherlands)

    Verheus, M.

    2007-01-01

    Worldwide, breast cancer is the most common malignancy among females. The total breast area on a mammogram can be dived in a radiologicaly dense area (glandular and stromal tissue) and a non-dense area (mainly fat tissue). Women with a high proportion of dense breast tissue (percent breast density)

  18. Circulating insulin-like growth factor-I, insulin-like growth factor binding protein-3 and terminal duct lobular unit involution of the breast: a cross-sectional study of women with benign breast disease.

    Science.gov (United States)

    Horne, Hisani N; Sherman, Mark E; Pfeiffer, Ruth M; Figueroa, Jonine D; Khodr, Zeina G; Falk, Roni T; Pollak, Michael; Patel, Deesha A; Palakal, Maya M; Linville, Laura; Papathomas, Daphne; Geller, Berta; Vacek, Pamela M; Weaver, Donald L; Chicoine, Rachael; Shepherd, John; Mahmoudzadeh, Amir Pasha; Wang, Jeff; Fan, Bo; Malkov, Serghei; Herschorn, Sally; Hewitt, Stephen M; Brinton, Louise A; Gierach, Gretchen L

    2016-02-18

    Terminal duct lobular units (TDLUs) are the primary structures from which breast cancers and their precursors arise. Decreased age-related TDLU involution and elevated mammographic density are both correlated and independently associated with increased breast cancer risk, suggesting that these characteristics of breast parenchyma might be linked to a common factor. Given data suggesting that increased circulating levels of insulin-like growth factors (IGFs) factors are related to reduced TDLU involution and increased mammographic density, we assessed these relationships using validated quantitative methods in a cross-sectional study of women with benign breast disease. Serum IGF-I, IGFBP-3 and IGF-I:IGFBP-3 molar ratios were measured in 228 women, ages 40-64, who underwent diagnostic breast biopsies yielding benign diagnoses at University of Vermont affiliated centers. Biopsies were assessed for three separate measures inversely related to TDLU involution: numbers of TDLUs per unit of tissue area ("TDLU count"), median TDLU diameter ("TDLU span"), and number of acini per TDLU ("acini count"). Regression models, stratified by menopausal status and adjusted for potential confounders, were used to assess the associations of TDLU count, median TDLU span and median acini count per TDLU with tertiles of circulating IGFs. Given that mammographic density is associated with both IGF levels and breast cancer risk, we also stratified these associations by mammographic density. Higher IGF-I levels among postmenopausal women and an elevated IGF-I:IGFBP-3 ratio among all women were associated with higher TDLU counts, a marker of decreased lobular involution (P-trend = 0.009 and breast cancer risk. If confirmed in prospective studies with cancer endpoints, these data may suggest that evaluation of IGF signaling and its downstream effects may have value for risk prediction and suggest strategies for breast cancer chemoprevention through inhibition of the IGF system.

  19. Nuclear Morphometry in Ductal Breast Carcinoma with Correlation to Cell Proliferative Activity and Prognosis

    International Nuclear Information System (INIS)

    Radwan, M.M.; Amer, K.A.; Mokhtar, N.M.

    2003-01-01

    Morphometry is the quantitative description of biologic structures. This study was designed to evaluate the efficiency of morphometric measurements in diagnosis and prognosis of patients with breast carcinoma. Methods: Histological samples from 61 patients of invasive duct carcinoma (IDC) of no special type (NST), 12 cases of ductal carcinoma in situ (DCIS) and 14 control breast samples taken from fibrocystic change disease were retrospectively analyzed by computerized nuclear morphometry. All IDC patients underwent modified radical mastectomy without preoperative chemotherapy. The mean follow up was 28±19 months (range] -71). In each case, 25-50 nuclei were measured and the mean nuclear area (MNA), mean nuclear perimeter (MNP), mean maximum nuclear diameter (MMNO) and mean minimal nuclear diameter (Mmnd) were measured. The mean axis ratio (MAR), mean nuclear compactness (MNC), mean nuclear size (MNS) and mean shape factor (MSHF), were calculated mathematically. To measure the nuclear diameters, a new method was employed using the AutoCAD program. Morphometric parameters were compared with different clinico pathologic features, patient's survival and cell proliferative activity as determined by Ki-67 immunostaining which was evaluated quantitatively. Most of the morphometric parameters were significantly higher in DCIS and IDC groups than benign one. In IDC group morphometric features related to nuclear size (MNA, MNP, MMNO, Mmnd and MNS) were significantly correlated to most clinico pathologic features and cell proliferative activity assessed by Ki-67 immunostaining. However, the shape factor failed to achieve this correlation. The univariate analysis using Kaplan Meier curves indicated that short survival time was correlated with high nuclear morphometric values (MNA. MNP, MMND, Mmnd, MNS and MSHF). Moreover, the Spear man correlation analysis showed that Mmnd has the highest converse correlation with survival (r= -0.75, (ρ < 0.0001). In multivariate analysis

  20. Electronic transport behavior of diameter-graded Ag nanowires

    International Nuclear Information System (INIS)

    Wang Xuewei; Yuan Zhihao

    2010-01-01

    Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.

  1. Electronic transport behavior of diameter-graded Ag nanowires

    Science.gov (United States)

    Wang, Xue Wei; Yuan, Zhi Hao

    2010-05-01

    Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.

  2. Lysosome Transport as a Function of Lysosome Diameter

    Science.gov (United States)

    Bandyopadhyay, Debjyoti; Cyphersmith, Austin; Zapata, Jairo A.; Kim, Y. Joseph; Payne, Christine K.

    2014-01-01

    Lysosomes are membrane-bound organelles responsible for the transport and degradation of intracellular and extracellular cargo. The intracellular motion of lysosomes is both diffusive and active, mediated by motor proteins moving lysosomes along microtubules. We sought to determine how lysosome diameter influences lysosome transport. We used osmotic swelling to double the diameter of lysosomes, creating a population of enlarged lysosomes. This allowed us to directly examine the intracellular transport of the same organelle as a function of diameter. Lysosome transport was measured using live cell fluorescence microscopy and single particle tracking. We find, as expected, the diffusive component of intracellular transport is decreased proportional to the increased lysosome diameter. Active transport of the enlarged lysosomes is not affected by the increased lysosome diameter. PMID:24497985

  3. Buckling Test Results from the 8-Foot-Diameter Orthogrid-Stiffened Cylinder Test Article TA01. [Test Dates: 19-21 November 2008

    Science.gov (United States)

    Hilburger, Mark W.; Waters, W. Allen, Jr.; Haynie, Waddy T.

    2015-01-01

    Results from the testing of cylinder test article SBKF-P2-CYLTA01 (referred to herein as TA01) are presented. The testing was conducted at the Marshall Space Flight Center (MSFC), November 19?21, 2008, in support of the Shell Buckling Knockdown Factor (SBKF) Project.i The test was used to verify the performance of a newly constructed buckling test facility at MSFC and to verify the test article design and analysis approach used by the SBKF project researchers. TA01 is an 8-foot-diameter (96-inches), 78.0-inch long, aluminum-lithium (Al-Li), orthogrid-stiffened cylindrical shell similar to those used in current state-of-the-art launch vehicle structures and was designed to exhibit global buckling when subjected to compression loads. Five different load sequences were applied to TA01 during testing and included four sub-critical load sequences, i.e., loading conditions that did not cause buckling or material failure, and one final load sequence to buckling and collapse. The sub-critical load sequences consisted of either uniform axial compression loading or combined axial compression and bending and the final load sequence subjected TA01 to uniform axial compression. Traditional displacement transducers and strain gages were used to monitor the test article response at nearly 300 locations and an advanced digital image correlation system was used to obtain low-speed and high-speed full-field displacement measurements of the outer surface of the test article. Overall, the test facility and test article performed as designed. In particular, the test facility successfully applied all desired load combinations to the test article and was able to test safely into the postbuckling range of loading, and the test article failed by global buckling. In addition, the test results correlated well with initial pretest predictions.

  4. Breast Prothesis Leakage and Malignant Changes of the Breast

    OpenAIRE

    Al-Lawati, Taha; Kutty, Rajyashree

    2009-01-01

    A breast implant is a prosthesis used to enhance the size of a woman’s breasts. Silicon implants are most commonly used, but as with all surgical implants it has some complications. The question is whether it can induce breast cancer? During the last year, a case of reconstructed breast with prosthesis which leaked was presented. The aim of this report is to review current literature to evaluate whether there are reported correlations between breast cancer and breast implants. The conclusion ...

  5. Breast MRI in pregnancy-associated breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Shin Jung; Shin, Sang Soo [Dept. of of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Lim, Hyo Soon; Baek, Jang Mi; Seon, Hyun Ju; Heo, Suk Hee; Kim, Jin Woong; Park, Min Ho [Chonnam National University Medical School, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of)

    2017-03-15

    The purpose of this study was to evaluate the usefulness of MR imaging and to describe the MR imaging findings of pregnancy-associated breast cancer. From 2006 to 2013, MR images of 23 patients with pregnancy-associated breast cancer were retrospectively evaluated. MR images were reviewed to evaluate lesion detection and imaging findings of pregnancy-associated breast cancer. MR images were analyzed by using the Breast Imaging Reporting and Data System and an additional MR-detected lesion with no mammographic or sonographic abnormality was determined. MR imaging depicted breast cancer in all patients, even in marked background parenchymal enhancement. Pregnancy-associated breast cancer was seen as a mass in 20 patients and as non-mass enhancement with segmental distribution in 3 patients. The most common features of the masses were irregular shape (85%), non-circumscribed margin (85%), and heterogeneous enhancement (60%). An additional site of cancer was detected with MR imaging in 5 patients (21.7%) and the type of surgery was changed. Pregnancy-associated breast cancer was usually seen as an irregular mass with heterogeneous enhancement on MR images. Although these findings were not specific, MR imaging was useful in evaluating the disease extent of pregnancy-associated breast cancer.

  6. Breast MRI in pregnancy-associated breast cancer

    International Nuclear Information System (INIS)

    Kim, Shin Jung; Shin, Sang Soo; Lim, Hyo Soon; Baek, Jang Mi; Seon, Hyun Ju; Heo, Suk Hee; Kim, Jin Woong; Park, Min Ho

    2017-01-01

    The purpose of this study was to evaluate the usefulness of MR imaging and to describe the MR imaging findings of pregnancy-associated breast cancer. From 2006 to 2013, MR images of 23 patients with pregnancy-associated breast cancer were retrospectively evaluated. MR images were reviewed to evaluate lesion detection and imaging findings of pregnancy-associated breast cancer. MR images were analyzed by using the Breast Imaging Reporting and Data System and an additional MR-detected lesion with no mammographic or sonographic abnormality was determined. MR imaging depicted breast cancer in all patients, even in marked background parenchymal enhancement. Pregnancy-associated breast cancer was seen as a mass in 20 patients and as non-mass enhancement with segmental distribution in 3 patients. The most common features of the masses were irregular shape (85%), non-circumscribed margin (85%), and heterogeneous enhancement (60%). An additional site of cancer was detected with MR imaging in 5 patients (21.7%) and the type of surgery was changed. Pregnancy-associated breast cancer was usually seen as an irregular mass with heterogeneous enhancement on MR images. Although these findings were not specific, MR imaging was useful in evaluating the disease extent of pregnancy-associated breast cancer

  7. Breast cancer diagnoses in 'Carlos Manuel de Cespedes Hospital' (Bayamo, Granma) in the Middle of the '90 and 20 years

    International Nuclear Information System (INIS)

    Serrat Gomez, Francisco; Tomatis, Mariano; Ponti, Antonio; APOF Working Group

    2009-01-01

    Aim: To evaluate the breast cancer diagnostic performance after the settlement of a clinical breast and Fine-Needle Aspiration service at the histopathology department of Carlos Manuel Cespedes provincial Hospital in Bayamo (Cuba). Two breast cancer case-series occurred in the period 1992-1995 (127 cases) and 2004-2008 (307 cases) in the 'Carlos Manuel de Cespedes' hospital were compared in order to evaluate the following indicators: proportion of in situ and pT1 cancers, number of lymph nodes from axillary dissection mentioned in the histopathological report, sensitivity of the cytological diagnoses and proportion of conservative surgery in the pT1 tumours . Data were imputed in the software QT (Quality Treatment audit system of breast cancer diagnoses) which includes outcome measures defined by the European Society Of Mastology (EUSOMA); QT was developed by a multidisciplinary team from the European Breast Cancer Network and provided by CPO-Piedmont, Turin (Italy). The Italian NGO Patologi Oltre Frontiera (APOF) was in charge of the improvement of the cytological laboratory and local pathologist's training for breast fine needle aspiration procedures. For the descriptive statistics the QT software was used. No is situ breast cancers were accounted among the 127 patients diagnosed in 1992-95, whereas in the period 2004-08 they were 15 on 307 cases (4.8%). In the latter period lump's mean diameter was mm 27.3 and 158 cases (51.5%) were pT1 cancers; in 1992-95 the mean diameter was mm 29.7 and the pT1 tumours were 60 on 127 (47.2%). In 2004-08 96 on 156 pT1 cancers (63.2%) were treated with conservative surgery which accounted for 17 on the 55 pT1 cases (30.9%) diagnosed in 1992-95 . A number of 9 or more lymph nodes were mentioned in 146 on 250 reports of the period 2004-08 (58.4%); they were 59 on 118 reports of the period 1992-95 (50.0%). The sensitivity of FNA diagnoses in 2004-08 was 72.7%; it was 69.4% in the period 1992-95. There is some evidence that the

  8. Library based x-ray scatter correction for dedicated cone beam breast CT

    International Nuclear Information System (INIS)

    Shi, Linxi; Zhu, Lei; Vedantham, Srinivasan; Karellas, Andrew

    2016-01-01

    Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal

  9. Library based x-ray scatter correction for dedicated cone beam breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Linxi; Zhu, Lei, E-mail: leizhu@gatech.edu [Nuclear and Radiological Engineering and Medical Physics Programs, The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Vedantham, Srinivasan; Karellas, Andrew [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States)

    2016-08-15

    Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal

  10. Evaluation of the BreastSimulator software platform for breast tomography

    Science.gov (United States)

    Mettivier, G.; Bliznakova, K.; Sechopoulos, I.; Boone, J. M.; Di Lillo, F.; Sarno, A.; Castriconi, R.; Russo, P.

    2017-08-01

    The aim of this work was the evaluation of the software BreastSimulator, a breast x-ray imaging simulation software, as a tool for the creation of 3D uncompressed breast digital models and for the simulation and the optimization of computed tomography (CT) scanners dedicated to the breast. Eight 3D digital breast phantoms were created with glandular fractions in the range 10%-35%. The models are characterised by different sizes and modelled realistic anatomical features. X-ray CT projections were simulated for a dedicated cone-beam CT scanner and reconstructed with the FDK algorithm. X-ray projection images were simulated for 5 mono-energetic (27, 32, 35, 43 and 51 keV) and 3 poly-energetic x-ray spectra typically employed in current CT scanners dedicated to the breast (49, 60, or 80 kVp). Clinical CT images acquired from two different clinical breast CT scanners were used for comparison purposes. The quantitative evaluation included calculation of the power-law exponent, β, from simulated and real breast tomograms, based on the power spectrum fitted with a function of the spatial frequency, f, of the form S(f)  =  α/f   β . The breast models were validated by comparison against clinical breast CT and published data. We found that the calculated β coefficients were close to that of clinical CT data from a dedicated breast CT scanner and reported data in the literature. In evaluating the software package BreastSimulator to generate breast models suitable for use with breast CT imaging, we found that the breast phantoms produced with the software tool can reproduce the anatomical structure of real breasts, as evaluated by calculating the β exponent from the power spectral analysis of simulated images. As such, this research tool might contribute considerably to the further development, testing and optimisation of breast CT imaging techniques.

  11. Knowledge of breast density and awareness of related breast cancer risk.

    Science.gov (United States)

    Manning, Mark A; Duric, Neb; Littrup, Peter; Bey-Knight, Lisa; Penner, Louis; Albrecht, Terrance L

    2013-06-01

    Little is known about women's knowledge of breast density or between-race differences in this knowledge. In the current study, we examined knowledge of breast density and awareness of its role as a breast cancer risk factor among women who had previously taken part in a breast imaging study. Seventy-seven women (54.5 % Black) returned a survey assessing perceptions and accuracy of breast density knowledge, knowledge of one's own breast density, and breast cancer risk awareness. White women had greater perceived knowledge of breast density compared to Black women; however, differences in the accuracy of definitions of breast density were due to education. Black women were less likely to know how dense their own breasts were. Black and White women both lacked awareness that having dense breast increased breast cancer risk. The results highlight the need to disseminate information regarding breast density to women, while ensuring that the information is equally accessible to both Black and White women.

  12. Combining quantitative and qualitative breast density measures to assess breast cancer risk.

    Science.gov (United States)

    Kerlikowske, Karla; Ma, Lin; Scott, Christopher G; Mahmoudzadeh, Amir P; Jensen, Matthew R; Sprague, Brian L; Henderson, Louise M; Pankratz, V Shane; Cummings, Steven R; Miglioretti, Diana L; Vachon, Celine M; Shepherd, John A

    2017-08-22

    Accurately identifying women with dense breasts (Breast Imaging Reporting and Data System [BI-RADS] heterogeneously or extremely dense) who are at high breast cancer risk will facilitate discussions of supplemental imaging and primary prevention. We examined the independent contribution of dense breast volume and BI-RADS breast density to predict invasive breast cancer and whether dense breast volume combined with Breast Cancer Surveillance Consortium (BCSC) risk model factors (age, race/ethnicity, family history of breast cancer, history of breast biopsy, and BI-RADS breast density) improves identifying women with dense breasts at high breast cancer risk. We conducted a case-control study of 1720 women with invasive cancer and 3686 control subjects. We calculated ORs and 95% CIs for the effect of BI-RADS breast density and Volpara™ automated dense breast volume on invasive cancer risk, adjusting for other BCSC risk model factors plus body mass index (BMI), and we compared C-statistics between models. We calculated BCSC 5-year breast cancer risk, incorporating the adjusted ORs associated with dense breast volume. Compared with women with BI-RADS scattered fibroglandular densities and second-quartile dense breast volume, women with BI-RADS extremely dense breasts and third- or fourth-quartile dense breast volume (75% of women with extremely dense breasts) had high breast cancer risk (OR 2.87, 95% CI 1.84-4.47, and OR 2.56, 95% CI 1.87-3.52, respectively), whereas women with extremely dense breasts and first- or second-quartile dense breast volume were not at significantly increased breast cancer risk (OR 1.53, 95% CI 0.75-3.09, and OR 1.50, 95% CI 0.82-2.73, respectively). Adding continuous dense breast volume to a model with BCSC risk model factors and BMI increased discriminatory accuracy compared with a model with only BCSC risk model factors (C-statistic 0.639, 95% CI 0.623-0.654, vs. C-statistic 0.614, 95% CI 0.598-0.630, respectively; P breasts and fourth

  13. Tetrofosmin in metastatic breast cancer

    International Nuclear Information System (INIS)

    Berghammer, P.; Obwegeser, R.; Ulm, M.; Wiltschke, C.; Kubista, E.; Sinzinger, H.; Zielinski, C.

    1997-01-01

    Tetrofosmin (1,2-bis[bis(2-ethoxyethyl)phosphino]ethan) is currently under investigation for its tumor seeking properties, encouraged by the incidental finding of a malignant breast-lesion on myocardial scintigraphy in 1995 (Rambaldi et al, Clin Nucl Med 1995) using tetrofosmin. Recent reports have confirmed tetrofosmins role in detecting primary tumors in breast cancer. To investigate whether tetrofosmin significantly helps detect metastatic lesions in such patients we performed tetrofosmin scintigraphy in 21 patients with metastatic breast cancer. Patients and methods: Median age of patients was 61 years. In one patient the primary site was unknown. All patients had at least one distant metastasis. 550 MBq of 99m-Tc-tetrofosmin was administered ten minutes before imaging was begun. After obtaining a planar image, a single photon emission computed tomography (SPECT) was done of every suspected distant lesion. CT-scans or MRI were used to confirm positive correlation with tetrofosmin scintigraphy. Results: Tetrofosmin scintigraphy correctly diagnosed metastatic disease in 71 % of patients with no false negative and two false positive results. In each of the two patients a mediastinal hot spot suggestive of malignancy was found, but none of those lesions could be proven using CT scans. Excluding patients with liver metastasis from the present analysis, 91 % of all metastasis would have been correctly diagnosed. The first patient in our department had a large metastasis in the upper mediastinum which could not be seen on regular chest films. In the patient in whom the primary site of cancer was unknown, tetrofosmin scintigraphy showed three consecutive nodules in the left mammary, gland in a coronary fashion. Magnetic resonance imaging then confirmed two single nodules of 0.8 cm in diameter. Conclusions: Evaluating 21 patients, the present study was performed to investigate tetrofosmins properties of detecting metastatic lesions in patients with breast cancer. A 91

  14. [Effect of elastic strain rate ratio method and virtual touch tissue quantification on the diagnosis of breast masses].

    Science.gov (United States)

    Gong, LiJie; He, Yan; Tian, Peng; Yan, Yan

    2016-07-01

    To determine the effect of elastic strain rate ratio method and virtual touch tissue quantification (VTQ) on the diagnosis of breast masses.
 Sixty female patients with breast cancer, who received surgical treatment in Daqing Oilfield General Hospital, were enrolled. All patients signed the informed consent paperwork and they were treated by routine ultrasound examination, compression elastography (CE) examination, and VTQ examination in turn. Strain ratio (SR) was checked by CE and shear wave velocity (SWV) value was measured by VTQ. The diagnostic values of different methods were evaluated by receiver operating characteristic (ROC) curves in the diagnosis of benign and malignant breast tumors.
 The maximum diameter and SWV value of the benign tumors were lower than those of the malignant tumors, and the SR ratio of benign masses was higher than that of malignant tumors (Pbreast mass than that used alone.

  15. Risk assessment of K basin twelve-inch drain valve failure from a postulated seismic initiating event

    International Nuclear Information System (INIS)

    MORGAN, R.G.

    1999-01-01

    The Spent Nuclear Fuel (SNF) Project will transfer metallic SNF from the Hanford 105 K-East and 105 K-West Basins to safe interim storage in the Canister Storage Building in the 200 Area. The initial basis for design, fabrication, installation, and operation of the fuel removal systems was that the basin leak rates which could result from a postulated accident condition would not be excessive relative to reasonable recovery operations. However, an additional potential K Basin water leak path is through the K Basin drain valves. Three twelve-inch drain valves are located in the main basin bays along the north wall. The sumps containing the valves are filled with concrete which covers the drain valve body. Visual observations suggest that only the valve's bonnet and stem are exposed above the basin concrete floor. It was recognized, however, that damage of the drain valve bonnet or stem during a seismic initiating event could provide a potential K Basin water leak path. The objectives of this activity are to: (1) evaluate the risk of damaging the three twelve-inch drain valves located along the north wall of the main basin from a seismic initiating event, and (2) determine the associated potential leak rate from a damaged valve

  16. Risk assessment of K basin twelve-inch drain valve failure from a postulated seismic initiating event

    Energy Technology Data Exchange (ETDEWEB)

    MORGAN, R.G.

    1999-04-06

    The Spent Nuclear Fuel (SNF) Project will transfer metallic SNF from the Hanford 105 K-East and 105 K-West Basins to safe interim storage in the Canister Storage Building in the 200 Area. The initial basis for design, fabrication, installation, and operation of the fuel removal systems was that the basin leak rates which could result from a postulated accident condition would not be excessive relative to reasonable recovery operations. However, an additional potential K Basin water leak path is through the K Basin drain valves. Three twelve-inch drain valves are located in the main basin bays along the north wall. The sumps containing the valves are filled with concrete which covers the drain valve body. Visual observations suggest that only the valve's bonnet and stem are exposed above the basin concrete floor. It was recognized, however, that damage of the drain valve bonnet or stem during a seismic initiating event could provide a potential K Basin water leak path. The objectives of this activity are to: (1) evaluate the risk of damaging the three twelve-inch drain valves located along the north wall of the main basin from a seismic initiating event, and (2) determine the associated potential leak rate from a damaged valve.

  17. Breast Cancer Treatment

    Science.gov (United States)

    ... of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Cancer Treatment (PDQ®)–Patient Version General Information About Breast Cancer Go to Health Professional Version Key Points Breast ...

  18. Stand mid-diameter extraction mid-distances influence in the harvesting costs of Eucalyptus globulus forest system in the Chile central zone

    International Nuclear Information System (INIS)

    Barrios, Alonso; Lopez, Ana M; Nieto, Victor M

    2008-01-01

    A whole tree and in-wood chipping harvesting system was studied by modelling and dynamic simulation. The iThink environment was used to build an application for simulating the operation of the harvesting system, using both deterministic and stochastic models (Isee systems, Inc. 2007). The variables used in this study were the mean diameter at breast height and the mean skidding distance of the stand. In this way, the influence of these variables in the systems cost per cubic meter was determined. This study exhibits a technical approach for establishing more appropriate payment fees, considering that the harvesting costs vary according to the stand characteristics.

  19. Breast Density and Benign Breast Disease: Risk Assessment to Identify Women at High Risk of Breast Cancer.

    Science.gov (United States)

    Tice, Jeffrey A; Miglioretti, Diana L; Li, Chin-Shang; Vachon, Celine M; Gard, Charlotte C; Kerlikowske, Karla

    2015-10-01

    Women with proliferative breast lesions are candidates for primary prevention, but few risk models incorporate benign findings to assess breast cancer risk. We incorporated benign breast disease (BBD) diagnoses into the Breast Cancer Surveillance Consortium (BCSC) risk model, the only breast cancer risk assessment tool that uses breast density. We developed and validated a competing-risk model using 2000 to 2010 SEER data for breast cancer incidence and 2010 vital statistics to adjust for the competing risk of death. We used Cox proportional hazards regression to estimate the relative hazards for age, race/ethnicity, family history of breast cancer, history of breast biopsy, BBD diagnoses, and breast density in the BCSC. We included 1,135,977 women age 35 to 74 years undergoing mammography with no history of breast cancer; 17% of the women had a prior breast biopsy. During a mean follow-up of 6.9 years, 17,908 women were diagnosed with invasive breast cancer. The BCSC BBD model slightly overpredicted risk (expected-to-observed ratio, 1.04; 95% CI, 1.03 to 1.06) and had modest discriminatory accuracy (area under the receiver operator characteristic curve, 0.665). Among women with proliferative findings, adding BBD to the model increased the proportion of women with an estimated 5-year risk of 3% or higher from 9.3% to 27.8% (P<.001). The BCSC BBD model accurately estimates women's risk for breast cancer using breast density and BBD diagnoses. Greater numbers of high-risk women eligible for primary prevention after BBD diagnosis are identified using the BCSC BBD model. © 2015 by American Society of Clinical Oncology.

  20. Breast cancer screening

    Science.gov (United States)

    Mammogram - breast cancer screening; Breast exam - breast cancer screening; MRI - breast cancer screening ... is performed to screen women to detect early breast cancer when it is more likely to be cured. ...

  1. Awareness of Breast Cancer and Breast Self Examination Among ...

    African Journals Online (AJOL)

    Background: Breast cancer is the commonest malignancy affecting women in Nigeria. Regular breast self examination reduces morbidity and mortality from this disease. Objective: To assess the knowledge of breast cancer, breast self examination and practice amongst secondary school teachers in Enugu , Nigeria.

  2. On-line ultrasonic inside-diameter control system for Zircaloy

    International Nuclear Information System (INIS)

    Tanaka, Y.; Fujii, N.; Komatsu, M.; Kubota, H.

    1984-01-01

    An ultrasonic inside-diameter (ID) control system was used during the final etching process for producing Zircaloy nuclear fuel cladding tubes. This results in establishing automatic inside-diameter control during etching with an automatic etching system. In this system, the inside-diameter at the center point in the length of each tube is continuously measured with the ultrasonic inside-diameter measuring equipment during the etching process and the etching is automatically stopped by a signal from the control equipment when the inside-diameter reaches the target value. This made the final etching process economical and suitable for large-scale production, having an equal or better level at the inside-diameter of tubes etched with this system than those made by a process controlled by an air-micrometer

  3. Quantitative contrast-enhanced ultrasound evaluation of pathological complete response in patients with locally advanced breast cancer receiving neoadjuvant chemotherapy.

    Science.gov (United States)

    Wan, Cai-Feng; Liu, Xue-Song; Wang, Lin; Zhang, Jie; Lu, Jin-Song; Li, Feng-Hua

    2018-06-01

    To clarify whether the quantitative parameters of contrast-enhanced ultrasound (CEUS) can be used to predict pathological complete response (pCR) in patients with locally advanced breast cancer receiving neoadjuvant chemotherapy (NAC). Fifty-one patients with histologically proved locally advanced breast cancer scheduled for NAC were enrolled. The quantitative data for CEUS and the tumor diameter were collected at baseline and before surgery, and compared with the pathological response. Multiple logistic regression analysis was performed to examine quantitative parameters at CEUS and the tumor diameter to predict the pCR, and receiver operating characteristic (ROC) curve analysis was used as a summary statistic. Multiple logistic regression analysis revealed that PEAK (the maximum intensity of the time-intensity curve during bolus transit), PEAK%, TTP% (time to peak), and diameter% were significant independent predictors of pCR, and the area under the ROC curve was 0.932(Az 1 ), and the sensitivity and specificity to predict pCR were 93.7% and 80.0%. The area under the ROC curve for the quantitative parameters was 0.927(Az 2 ), and the sensitivity and specificity to predict pCR were 81.2% and 94.3%. For diameter%, the area under the ROC curve was 0.786 (Az 3 ), and the sensitivity and specificity to predict pCR were 93.8% and 54.3%. The values of Az 1 and Az 2 were significantly higher than that of Az 3 (P = 0.027 and P = 0.034, respectively). However, there was no significant difference between the values of Az 1 and Az 2 (P = 0.825). Quantitative analysis of tumor blood perfusion with CEUS is superior to diameter% to predict pCR, and can be used as a functional technique to evaluate tumor response to NAC. Copyright © 2018. Published by Elsevier B.V.

  4. The evolving role of the breast physician in the multidisciplinary breast team.

    Science.gov (United States)

    Brennan, Meagan; Spillane, Andrew

    2007-10-01

    Breast physicians are medical practitioners trained in the diagnosis and management of breast disease. This relatively small group of specialized clinicians has a unique and expanding role in multidisciplinary breast teams in Australia and New Zealand. With minimal available published works, this article studies the varied roles that breast physicians carry out and the way they participate in the multidisciplinary team. Investigation of their current roles in breast medicine identified breast physicians providing a broad range of clinical care in public and private breast clinics and breast screening programmes as well as holding academic and administrative positions in clinical and non-clinical organizations. Numerous benefits for patients and for specialist breast clinicians working in partnership with breast physicians were identified. Breast surgeons are often the most advantaged by the contributions made by the breast physician to the multidisciplinary breast-care team with breast physicians particularly adding value to the service provided by breast surgeons. Breast physicians are well-trained, highly valuable members of the multidisciplinary breast team with a skill set that may enhance patient care at all stages from diagnosis to treatment to follow up.

  5. John Day Lock and Dam Juvenile Fish Bypass System, Columbia River, Oregon-Washington. Supplement No. 3 to General Letter Report, Transportation Conduit and Outfall

    Science.gov (United States)

    1983-06-01

    integral with the chute section. The chute section is supported vertically by a column and beam frame and is connected horizon- tally to existing...inch diameter steel pipe piles concreted into 42-inch diameter drilled holes. The pipe piles will be connected at the top by a precast concrete beam ...frames. A typical frame has 2-foot square columns , a 2-foot by 3-foot cross beam , and a 6-foot by 15-foot footing. One frame will support the

  6. Breast Cancer Prevention

    Science.gov (United States)

    ... of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Cancer Prevention (PDQ®)–Patient Version What is prevention? Go ... from starting. Risk-reducing surgery . General Information About Breast Cancer Key Points Breast cancer is a disease in ...

  7. Nanoparticles target early-stage breast cancer metastasis in vivo

    Science.gov (United States)

    Goldman, Evgeniya; Zinger, Assaf; da Silva, Dana; Yaari, Zvi; Kajal, Ashima; Vardi-Oknin, Dikla; Goldfeder, Mor; Schroeder, Josh E.; Shainsky-Roitman, Janna; Hershkovitz, Dov; Schroeder, Avi

    2017-10-01

    Despite advances in cancer therapy, treating cancer after it has metastasized remains an unmet clinical challenge. In this study we demonstrate that 100 nm liposomes target triple-negative murine breast-cancer metastases post intravenous administration. Metastatic breast cancer was induced in BALB/c mice either experimentally, by a tail vein injection of 4T1 cells, or spontaneously, after implanting a primary tumor xenograft. To track their biodistribution in vivo the liposomes were labeled with multi-modal diagnostic agents, including indocyanine green and rhodamine for whole-animal fluorescent imaging, gadolinium for magnetic resonance imaging (MRI), and europium for a quantitative biodistribution analysis. The accumulation of liposomes in the metastases peaked at 24 h post the intravenous administration, similar to the time they peaked in the primary tumor. The efficiency of liposomal targeting to the metastatic tissue exceeded that of a non-liposomal agent by 4.5-fold. Liposomes were detected at very early stages in the metastatic progression, including metastatic lesions smaller than 2 mm in diameter. Surprisingly, while nanoparticles target breast cancer metastasis, they may also be found in elevated levels in the pre-metastatic niche, several days before metastases are visualized by MRI or histologically in the tissue. This study highlights the promise of diagnostic and therapeutic nanoparticles for treating metastatic cancer, possibly even for preventing the onset of the metastatic dissemination by targeting the pre-metastatic niche.

  8. Breast Abscess Mimicking Breast Carcinoma in Male.

    Science.gov (United States)

    Gochhait, Debasis; Dehuri, Priyadarshini; Umamahesweran, Sandyya; Kamat, Rohan

    2018-01-01

    Male breast can show almost all pathological entities described in female breast. Inflammatory conditions of the breast in male are not common; however, occasionally, it can be encountered in the form of an abscess. Clinically, gynecomastia always presents as a symmetric unilateral or bilateral lump in the retroareolar region, and any irregular asymmetric lump raises a possibility of malignancy. Radiology should be used as a part of the triple assessment protocol for breast lump along with fine-needle aspiration cytology for definite diagnosis and proper management.

  9. ED breast cases and other breast emergencies.

    Science.gov (United States)

    Khadem, Nasim; Reddy, Sravanthi; Lee, Sandy; Larsen, Linda; Walker, Daphne

    2016-02-01

    Patients with pathologic processes of the breast commonly present in the Emergency Department (ED). Familiarity with the imaging and management of the most common entities is essential for the radiologist. Additionally, it is important to understand the limitations of ED imaging and management in the acute setting and to recognize when referrals to a specialty breast center are necessary. The goal of this article is to review the clinical presentations, pathophysiology, imaging, and management of emergency breast cases and common breast pathology seen in the ED.

  10. Association between breast cancer, breast density, and body adiposity evaluated by MRI

    International Nuclear Information System (INIS)

    Zhu, Wenlian; Huang, Peng; Macura, Katarzyna J.; Artemov, Dmitri

    2016-01-01

    Despite the lack of reliable methods with which to measure breast density from 2D mammograms, numerous studies have demonstrated a positive association between breast cancer and breast density. The goal of this study was to study the association between breast cancer and body adiposity, as well as breast density quantitatively assessed from 3D MRI breast images. Breast density was calculated from 3D T1-weighted MRI images. The thickness of the upper abdominal adipose layer was used as a surrogate marker for body adiposity. We evaluated the correlation between breast density, age, body adiposity, and breast cancer. Breast density was calculated for 410 patients with unilateral invasive breast cancer, 73 patients with ductal carcinoma in situ (DCIS), and 361 controls without breast cancer. Breast density was inversely related to age and the thickness of the upper abdominal adipose layer. Breast cancer was only positively associated with body adiposity and age. Age and body adiposity are predictive of breast density. Breast cancer was not associated with breast density; however, it was associated with the thickness of the upper abdominal adipose layer, a surrogate marker for body adiposity. Our results based on a limited number of patients warrant further investigations. (orig.)

  11. Ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage

    International Nuclear Information System (INIS)

    Naper, M.A.; Shaikh, M.S.; Dholia, K.R.

    2017-01-01

    To evaluate the outcome and assess the success rate of ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage. Methodology: A prospective descriptive study was carried out at Department of Surgery, Chandka Medical College Hospital, Larkana, Pakistan, from January 2015 to December 2015. A total of 111 patients of breast abscess who underwent ultrasound guided aspiration without anesthesias with oral antibiotic cover were studied. Females with breast abscess within seven days, and the abscess size was <3cm were included in the study. Males, antibioma and inflammatory carcinoma were excluded from the study. Outcome of success or failure was observed within two weeks and recorded. Results: Out of 111 patients, 68.46% were lactating and 31.53% were non-lactating women, with ages ranging from 18 to 60 years (mean 36.5 years). The successful rate with complete resolution after ultrasound guided aspiration was observed in 94.5%. 80.82% responded after single aspiration, 12.38% after two times aspiration, and 6.66% after multiple aspirations, while 5.4% of patients required incision and drainage. Conclusion: Ultrasound guided aspiration of breast abscess is an effective treatment option with a diameter of <3cm, which can be recommended as a routine outpatient procedure. (author)

  12. Laser direct writing using submicron-diameter fibers.

    Science.gov (United States)

    Tian, Feng; Yang, Guoguang; Bai, Jian; Xu, Jianfeng; Hou, Changlun; Liang, Yiyong; Wang, Kaiwei

    2009-10-26

    In this paper, a novel direct writing technique using submicron-diameter fibers is presented. The submicron-diameter fiber probe serves as a tightly confined point source and it adopts micro touch mode in the process of writing. The energy distribution of direct writing model is analyzed by Three-Dimension Finite-Difference Time-Domain method. Experiments demonstrate that submicron-diameter fiber direct writing has some advantages: simple process, 350-nm-resolution (lower than 442-nm-wavelength), large writing area, and controllable width of lines. In addition, by altering writing direction of lines, complex submicron patterns can be fabricated.

  13. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2004-04-01

    optimize the design of the robot elements and surface control electronics and software. Task 6 (Design & Build Surface Control and Monitoring System) has been completed with the control and computer display functions being operated through LabView. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to completing the detailed design of the entry fitting for 12-inch diameter cast iron pipe. The fitting is now being placed into manufacture. Task 8--System Integration and Laboratory Validation continued developing the robot module inter-connects and development of a master LabView-based system display and control software.

  14. Sensitivity of imaging for multifocal-multicentric breast carcinoma

    Directory of Open Access Journals (Sweden)

    Viale Giuseppe

    2008-09-01

    .5%. Re-reviewed Mx detected only 3 additional lesions. The sensitivity of Mx was affected by the presence of dense breast tissue which obscured lesions or by an incorrect interpretation of suspicious findings. US detected 73/80 index cancers (sensitivity of 91.2%, US missed 117 malignant foci with a mean tumor diameter of 6.5 mm; the sensitivity was 52.9% Undetected lesions by US were those smallest in size and present in fatty breast or in the presence of microcalcifications without a visible mass. US sensitivity was affected by the presence of fatty tissue or by the extent of calcification. Conclusion Mx missed MMBC malignant foci more often in dense or fibroglandular breasts. US missed small lesions in mainly fatty breasts or when there were only microcalcifications. The combined sensitivity of both techniques to assess MMBC was 58%. We suggest larger studies on multimodality imaging.

  15. Different Patterns of Changes in the Dry Season Diameter at Breast Height of Dominant and Evergreen Tree Species in a Mature Subtropical Forest in South China

    Institute of Scientific and Technical Information of China (English)

    Jun-Hua Yan; Guo-Yi Zhou; De-Qiang Zhang; Xu-Li Tang; Xu Wang

    2006-01-01

    Information on changes in diameter at breast height (DBH) is important for net primary production (NPP)estimates, timing of forest inventory, and forest management. In the present study, patterns of DBH change were measured under field conditions during the dry season for three dominant and native tree species in a monsoon evergreen broad-leaved forest in the Dinghushan Biosphere Reserve. For each tree species,different patterns of DBH change were observed. In the case of the fast-growing tree species Castanopsis chinensis Hance, large diurnal fluctuations occur, with a peak DBH in the early morning (around 05:00 h) that decreases to a minimum by about 14:00 h. Both Schima superba Gardn. et Chemp and Cryptocarya chinensis (Hance) Hemsl. exhibited less diurnal swelling and shrinkage. Diurnal fluctuations for these species were observed on a few occasions over the period of observation. Graphical comparisons and statistical analysis of changes in DBH with meteorological variables indicate that for different trees, the different changes in DBH observed responded to different meteorological variables. Large stem changes were found to occur for Ca. chinensis trees that were associated with variations in solar radiation. However, both S. superba and Cr. chinensis were found to be less sensitive to solar radiation. Changes in the DBH of these two species were found to be controlled mainly by soil temperature and soil moisture. During the later dry season, with a lower soil temperature and soil moisture, all three tree species stopped growing and only negligible shrinkage, expansion, or fluctuation occurred, suggesting that the optimum time to measure tree growth in the Dinghushan Biosphere Reserve is the later dry season.

  16. Breast cancer detection using sonography in women with mammographically dense breasts

    International Nuclear Information System (INIS)

    Okello, Jimmy; Kisembo, Harriet; Bugeza, Sam; Galukande, Moses

    2014-01-01

    Mammography, the gold standard for breast cancer screening misses some cancers, especially in women with dense breasts. Breast ultrasonography as a supplementary imaging tool for further evaluation of symptomatic women with mammographically dense breasts may improve the detection of mass lesions otherwise missed at mammography. The purpose of this study was to determine the incremental breast cancer detection rate using US scanning in symptomatic women with mammographically dense breasts in a resource poor environment. A cross sectional descriptive study. Women referred for mammography underwent bilateral breast ultrasound, and mammography for symptom evaluation. The lesions seen by both modalities were described using sonographic BI-RADS lexicon and categorized. Ultrasound guided core biopsies were performed. IRB approval was obtained and all participants provided informed written consent. In total 148 women with mammographically dense breasts were recruited over six months. The prevalence of breast cancer in symptomatic women with mammographically dense breasts was 22/148 (15%). Mammography detected 16/22 (73%) of these cases and missed 6/22 (27%). The six breast cancer cases missed were correctly diagnosed on breast ultrasonography. Sonographic features typical of breast malignancy were irregular shape, non-parallel orientation, non circumscribed margin, echogenic halo, and increased lesion vascularity (p values < 0.005). Typical sonofeatures of benign mass lesions were: oval shape, parallel orientation and circumscribed margin (p values <0.005). Breast ultrasound scan as a supplementary imaging tool detected 27% more malignant mass lesions otherwise missed by mammography among these symptomatic women with mammographically dense breasts. We recommend that ultra sound scanning in routine evaluation of symptomatic women with mammographically dense breasts

  17. Efficacy of breast conservation therapy in early stage bilateral breast cancer

    International Nuclear Information System (INIS)

    Lee, Misa M.; Chen, Luci M.; Heimann, Ruth; Powers, Claire; Weichselbaum, Ralph R.

    1996-01-01

    PURPOSE: To evaluate outcome of patients with bilateral breast cancer as compared to unilateral breast cancer treated with breast conservation therapy. This is a complex issue, however, we address this by comparing (1) synchronous bilateral breast cancer patients, (2) metachronous bilateral breast cancer patients from the time of diagnosis of the second breast primary, and (3) unilateral breast cancer patients. The authors recognize that there are inherent biases in these comparisons. MATERIALS AND METHODS: A total of 60 bilateral patients and 1080 unilateral patients treated with breast conservation therapy from 1977-1994 were analyzed for outcome. Of the 60 bilateral patients, 44 were metachronous bilateral breast cancer patients (MBBC) and 16 were synchronous breast cancer patients (SBBC). Patients with bilateral breast cancer had local-regional disease with the following tumor stages: DCIS=8%, T1=80%, T2=12%, pathologic N0=90%, pathologic N+=10%. Unilateral patients had the following tumor stages: DCIS=10%, T1=66%, T2=20%, T3=1.2%, Tx=2%, pathological N0=80%, pathological N+=19%, and NX=1%. The majority of patients received lumpectomy and axillary node dissection followed by radiation therapy. The median size of the lesions were 1.4cm and 1.5cm for bilateral and unilateral patients, respectively. Median total dose to the primary tumor was 60Gy for both unilateral and bilateral patients. Of the 44 metachronous bilateral breast cancer patients, 14 patients received breast conservation for both the first and second lesions while 30 patients had breast conservation for only the second metachronous breast lesion. Thus 58 lesions in the 44 patients were treated with breast conservation therapy in the patients with metachronous bilateral breast cancer. Of the synchronous bilateral breast cancer patients, 13 out of 16 patients had breast conserving therapy for both breasts, and 3 patients received mastectomy for the second synchronous breast tumor. The median follow

  18. Breast Abscess Mimicking Breast Carcinoma in Male

    Directory of Open Access Journals (Sweden)

    Debasis Gochhait

    2018-01-01

    Full Text Available Male breast can show almost all pathological entities described in female breast. Inflammatory conditions of the breast in male are not common; however, occasionally, it can be encountered in the form of an abscess. Clinically, gynecomastia always presents as a symmetric unilateral or bilateral lump in the retroareolar region, and any irregular asymmetric lump raises a possibility of malignancy. Radiology should be used as a part of the triple assessment protocol for breast lump along with fine-needle aspiration cytology for definite diagnosis and proper management.

  19. First clinical experience with a dedicated MRI-guided high-intensity focused ultrasound system for breast cancer ablation

    Energy Technology Data Exchange (ETDEWEB)

    Merckel, Laura G.; Knuttel, Floor M.; Peters, Nicky H.G.M.; Mali, Willem P.T.M.; Bosch, Maurice A.A.J. van den [University Medical Center Utrecht, Department of Radiology, HP E 01.132, Utrecht (Netherlands); Deckers, Roel; Moonen, Chrit T.W.; Bartels, Lambertus W. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Dalen, Thijs van [Diakonessenhuis Utrecht, Department of Surgery, Utrecht (Netherlands); Schubert, Gerald [Philips Healthcare, Best (Netherlands); Weits, Teun [Diakonessenhuis Utrecht, Department of Radiology, Utrecht (Netherlands); Diest, Paul J. van [University Medical Center Utrecht, Department of Pathology, Utrecht (Netherlands); Vaessen, Paul H.H.B. [University Medical Center Utrecht, Department of Anesthesiology, Utrecht (Netherlands); Gorp, Joost M.H.H. van [Diakonessenhuis Utrecht, Department of Pathology, Utrecht (Netherlands)

    2016-11-15

    To assess the safety and feasibility of MRI-guided high-intensity focused ultrasound (MR-HIFU) ablation in breast cancer patients using a dedicated breast platform. Patients with early-stage invasive breast cancer underwent partial tumour ablation prior to surgical resection. MR-HIFU ablation was performed using proton resonance frequency shift MR thermometry and an MR-HIFU system specifically designed for breast tumour ablation. The presence and extent of tumour necrosis was assessed by histopathological analysis of the surgical specimen. Pearson correlation coefficients were calculated to assess the relationship between sonication parameters, temperature increase and size of tumour necrosis at histopathology. Ten female patients underwent MR-HIFU treatment. No skin redness or burns were observed in any of the patients. No correlation was found between the applied energy and the temperature increase. In six patients, tumour necrosis was observed with a maximum diameter of 3-11 mm. In these patients, the number of targeted locations was equal to the number of areas with tumour necrosis. A good correlation was found between the applied energy and the size of tumour necrosis at histopathology (Pearson = 0.76, p = 0.002). Our results show that MR-HIFU ablation with the dedicated breast system is safe and results in histopathologically proven tumour necrosis. (orig.)

  20. Initial clinical test of a breast-PET scanner

    International Nuclear Information System (INIS)

    Raylman, Raymond R.; Koren, Courtney; Schreiman, Judith S.; Majewski, Stan; Marano, Gary D.; Abraham, Jame; Kurian, Sobha; Hazard, Hannah; Filburn, Shannon

    2011-01-01

    The goal of this initial clinical study was to test a new positron emission/tomography imager and biopsy system (PEM/PET) in a small group of selected subjects to assess its clinical imaging capabilities. Specifically, the main task of this study is to determine whether the new system can successfully be used to produce images of known breast cancer and compare them to those acquired by standard techniques. The PEM/PET system consists of two pairs of rotating radiation detectors located beneath a patient table. The scanner has a spatial resolution of ∼2 mm in all three dimensions. The subjects consisted of five patients diagnosed with locally advanced breast cancer ranging in age from 40 to 55 years old scheduled for pre-treatment, conventional whole body PET imaging with F-18 Fluorodeoxyglucose (FDG). The primary lesions were at least 2 cm in diameter. The images from the PEM/PET system demonstrated that this system is capable of identifying some lesions not visible in standard mammograms. Furthermore, while the relatively large lesions imaged in this study where all visualised by a standard whole body PET/CT scanner, some of the morphology of the tumours (ductal infiltration, for example) was better defined with the PEM/PET system. Significantly, these images were obtained immediately following a standard whole body PET scan. The initial testing of the new PEM/PET system demonstrated that the new system is capable of producing good quality breast-PET images compared standard methods.

  1. Breast Cancer Surgery

    Science.gov (United States)

    FACTS FOR LIFE Breast Cancer Surgery The goal of breast cancer surgery is to remove the whole tumor from the breast. Some lymph nodes ... might still be in the body. Types of breast cancer surgery There are two types of breast cancer ...

  2. EXPERIMENTAL BUBBLE FORMATION IN A LARGE SCALE SYSTEM FOR NEWTONIAN AND NONNEWTONIAN FLUIDS

    Energy Technology Data Exchange (ETDEWEB)

    Leishear, R; Michael Restivo, M

    2008-06-26

    The complexities of bubble formation in liquids increase as the system size increases, and a photographic study is presented here to provide some insight into the dynamics of bubble formation for large systems. Air was injected at the bottom of a 28 feet tall by 30 inch diameter column. Different fluids were subjected to different air flow rates at different fluid depths. The fluids were water and non-Newtonian, Bingham plastic fluids, which have yield stresses requiring an applied force to initiate movement, or shearing, of the fluid. Tests showed that bubble formation was significantly different in the two types of fluids. In water, a field of bubbles was formed, which consisted of numerous, distributed, 1/4 to 3/8 inch diameter bubbles. In the Bingham fluid, large bubbles of 6 to 12 inches in diameter were formed, which depended on the air flow rate. This paper provides comprehensive photographic results related to bubble formation in these fluids.

  3. The role of cone-beam breast-CT for breast cancer detection relative to breast density.

    Science.gov (United States)

    Wienbeck, Susanne; Uhlig, Johannes; Luftner-Nagel, Susanne; Zapf, Antonia; Surov, Alexey; von Fintel, Eva; Stahnke, Vera; Lotz, Joachim; Fischer, Uwe

    2017-12-01

    To evaluate the impact of breast density on the diagnostic accuracy of non-contrast cone-beam breast computed tomography (CBBCT) in comparison to mammography for the detection of breast masses. A retrospective study was conducted from August 2015 to July 2016. Fifty-nine patients (65 breasts, 112 lesions) with BI-RADS, 5th edition 4 or 5 assessment in mammography and/or ultrasound of the breast received an additional non-contrast CBBCT. Independent double blind reading by two radiologists was performed for mammography and CBBCT imaging. Sensitivity, specificity and AUC were compared between the modalities. Breast lesions were histologically examined in 85 of 112 lesions (76%). The overall sensitivity for CBBCT (reader 1: 91%, reader 2: 88%) was higher than in mammography (both: 68%, pdensity group (pdensity breasts. • Overall sensitivity for non-contrast CBBCT ranged between 88%-91%. • Sensitivity was higher for CBBCT than mammography in both density types (pdensity types (pdensity types (p<0.001).

  4. Pseudomonal breast infection

    Science.gov (United States)

    Rastall, S; Catchpole, C; Bright-Thomas, R; Thrush, S

    2010-01-01

    Breast infection and breast sepsis secondary to Pseudomonas aeruginosa is uncommon. We report two cases of pseudomonal breast infection leading to septic shock and abscess formation in women with non-responding breast infection. The management of breast infection is broad-spectrum antibiotics and ultrasound with aspiration of any collection. To treat breast infection effectively, the causative organism must be isolated to enable appropriate antibiotic therapy. PMID:20412664

  5. Diagnostic features of quantitative comb-push shear elastography for breast lesion differentiation.

    Science.gov (United States)

    Bayat, Mahdi; Denis, Max; Gregory, Adriana; Mehrmohammadi, Mohammad; Kumar, Viksit; Meixner, Duane; Fazzio, Robert T; Fatemi, Mostafa; Alizad, Azra

    2017-01-01

    Lesion stiffness measured by shear wave elastography has shown to effectively separate benign from malignant breast masses. The aim of this study was to evaluate different aspects of Comb-push Ultrasound Shear Elastography (CUSE) performance in differentiating breast masses. With written signed informed consent, this HIPAA- compliant, IRB approved prospective study included patients from April 2014 through August 2016 with breast masses identified on conventional imaging. Data from 223 patients (19-85 years, mean 59.93±14.96 years) with 227 suspicious breast masses identifiable by ultrasound (mean size 1.83±2.45cm) were analyzed. CUSE was performed on all patients. Three regions of interest (ROI), 3 mm in diameter each, were selected inside the lesion on the B-mode ultrasound which also appeared in the corresponding shear wave map. Lesion elasticity values were measured in terms of the Young's modulus. In correlation to pathology results, statistical analyses were performed. Pathology revealed 108 lesions as malignant and 115 lesions as benign. Additionally, 4 lesions (BI-RADS 2 and 3) were considered benign and were not biopsied. Average lesion stiffness measured by CUSE resulted in 84.26% sensitivity (91 of 108), 89.92% specificity (107 of 119), 85.6% positive predictive value, 89% negative predictive value and 0.91 area under the curve (P 0.21). CUSE was able to distinguish between benign and malignant breast masses with high sensitivity and specificity. Continuity of stiffness maps allowed for choosing multiple quantification ROIs which covered large areas of lesions and resulted in similar diagnostic performance based on average and maximum elasticity. The overall results of this study, highlights the clinical value of CUSE in differentiation of breast masses based on their stiffness.

  6. Diagnostic features of quantitative comb-push shear elastography for breast lesion differentiation.

    Directory of Open Access Journals (Sweden)

    Mahdi Bayat

    Full Text Available Lesion stiffness measured by shear wave elastography has shown to effectively separate benign from malignant breast masses. The aim of this study was to evaluate different aspects of Comb-push Ultrasound Shear Elastography (CUSE performance in differentiating breast masses.With written signed informed consent, this HIPAA- compliant, IRB approved prospective study included patients from April 2014 through August 2016 with breast masses identified on conventional imaging. Data from 223 patients (19-85 years, mean 59.93±14.96 years with 227 suspicious breast masses identifiable by ultrasound (mean size 1.83±2.45cm were analyzed. CUSE was performed on all patients. Three regions of interest (ROI, 3 mm in diameter each, were selected inside the lesion on the B-mode ultrasound which also appeared in the corresponding shear wave map. Lesion elasticity values were measured in terms of the Young's modulus. In correlation to pathology results, statistical analyses were performed.Pathology revealed 108 lesions as malignant and 115 lesions as benign. Additionally, 4 lesions (BI-RADS 2 and 3 were considered benign and were not biopsied. Average lesion stiffness measured by CUSE resulted in 84.26% sensitivity (91 of 108, 89.92% specificity (107 of 119, 85.6% positive predictive value, 89% negative predictive value and 0.91 area under the curve (P 0.21.CUSE was able to distinguish between benign and malignant breast masses with high sensitivity and specificity. Continuity of stiffness maps allowed for choosing multiple quantification ROIs which covered large areas of lesions and resulted in similar diagnostic performance based on average and maximum elasticity. The overall results of this study, highlights the clinical value of CUSE in differentiation of breast masses based on their stiffness.

  7. Breast MRI scan

    Science.gov (United States)

    ... or breast ultrasound Evaluate for possible rupture of breast implants Find any cancer that remains after surgery or chemotherapy Show blood ... Mean Abnormal results may be due to: Breast cancer Cysts Leaking or ruptured breast implants Abnormal breast tissue that is not cancer Scar ...

  8. Normal ureteral diameter in infancy and childhood

    International Nuclear Information System (INIS)

    Hellstroem, M.; Hjaelmaas, K.; Jacobsson, B.; Jodal, U.; Oden, A.; Oestra Sjukhuset, Goeteborg; Oestra Sjukhuset, Goeteborg; Goeteborg Univ.

    1985-01-01

    Ureteral diameters were estimated on films from intravenous urography in 194 children (100 boys and 94 girls) aged 0-16 years. Children with signs of urinary tract infection, calculi, obstruction, duplication or malformation were excluded. Films obtained without abdominal compression were used for measurements, including only ureters visualized over 50 per cent of their lengths. A good correlation was demonstrated between ureteral diameter and age and between ureteral diameter and the length of a segment of the lumbar spine. The widest part of the ureter was most often located just above the crossing of the iliac vessels. The right ureter was slightly wider than the left one. No difference between boys and girls was noted. The results are in good agreement with those of others obtained at autopsy. Bearing in mind the possible physiologic variations, it would seem that measuring the ureteral diameter can be of value for a more objective differentiation between dilated and non-dilated ureters. (orig.)

  9. Imaging Management of Breast Density, a Controversial Risk Factor for Breast Cancer.

    Science.gov (United States)

    Falcon, Shannon; Williams, Angela; Weinfurtner, Jared; Drukteinis, Jennifer S

    2017-04-01

    Breast density is well recognized as an independent risk factor for the development of breast cancer. However, the magnitude of risk is controversial. As the public becomes increasingly aware of breast density as a risk factor, legislation and notification laws in relation to breast density have become common throughout the United States. Awareness of breast density as a risk factor for breast cancer presents new challenges for the clinician in the approach to the management and screening of women with dense breasts. The evidence and controversy surrounding breast density as a risk factor for the development of breast cancer are discussed. Common supplemental screening modalities for breast cancer are also discussed, including tomosynthesis, ultrasonography, and magnetic resonance imaging. A management strategy for screening women with dense breasts is also presented. The American College of Radiology recognizes breast density as a controversial risk factor for breast cancer, whereas the American Congress of Obstetricians and Gynecologists recognizes breast density as a modest risk factor. Neither organization recommends the routine use of supplemental screening in women with dense breasts without considering additional patient-related risk factors. Breast density is a poorly understood and controversial risk factor for the development of breast cancer. Mammography is a screening modality proven to reduce breast cancer-related mortality rates and is the single most appropriate tool for population-based screening. Use of supplemental screening modalities should be tailored to individual risk assessment.

  10. Nodular Fasciitis of the Breast Mimicking Breast Cancer

    Directory of Open Access Journals (Sweden)

    Shinya Yamamoto

    2014-01-01

    Full Text Available Nodular fasciitis is a benign proliferative lesion that is usually found in the soft tissue of the upper extremity and trunk in young to middle-aged persons. It has rarely been described in the breast. A 35-year-old woman had noticed a mass in her left breast. It was elastic-hard, 13 mm in size, and located mainly in the upper inner quadrant of the left breast. Mammography did not detect the mass. Ultrasonography revealed a hypoechoic lesion with an irregular margin. Neither fine-needle aspiration cytology nor core needle biopsy established a definitive diagnosis. Excisional biopsy was therefore performed. Histologically, the excised tumor tissue results were consistent with a diagnosis of nodular fasciitis of the breast. We report a case of nodular fasciitis of the breast, a rare histological type of breast tumor.

  11. LOFT transient thermal analysis for 10 inch primary coolant blowdown piping weld

    International Nuclear Information System (INIS)

    Howell, S.K.

    1978-01-01

    A flaw in a weld in the 10 inch primary coolant blowdown piping was discovered by LOFT personnel. As a result of this, a thermal analysis and fracture mechanics analysis was requested by LOFT personnel. The weld and pipe section were analyzed for a complete thermal cycle, heatup and Loss of Coolant Experiment (LOCE), using COUPLE/MOD2, a two-dimensional finite element heat conduction code. The finite element representation used in this analysis was generated by the Applied Mechanics Branch. The record of nodal temperatures for the entire transient was written on tape VSN=T9N054, and has been forwarded to the Applied Mechanics Branch for use in their mechanical analysis. Specific details and assumptions used in this analysis are found in appropriate sections of this report

  12. Nanoencapsulation of pomegranate bioactive compounds for breast cancer chemoprevention.

    Science.gov (United States)

    Shirode, Amit B; Bharali, Dhruba J; Nallanthighal, Sameera; Coon, Justin K; Mousa, Shaker A; Reliene, Ramune

    2015-01-01

    Pomegranate polyphenols are potent antioxidants and chemopreventive agents but have low bioavailability and a short half-life. For example, punicalagin (PU), the major polyphenol in pomegranates, is not absorbed in its intact form but is hydrolyzed to ellagic acid (EA) moieties and rapidly metabolized into short-lived metabolites of EA. We hypothesized that encapsulation of pomegranate polyphenols into biodegradable sustained release nanoparticles (NPs) may circumvent these limitations. We describe here the development, characterization, and bioactivity assessment of novel formulations of poly(D,L-lactic-co-glycolic acid)-poly(ethylene glycol) (PLGA-PEG) NPs loaded with pomegranate extract (PE) or individual polyphenols such as PU or EA. Monodispersed, spherical 150-200 nm average diameter NPs were prepared by the double emulsion-solvent evaporation method. Uptake of Alexa Fluor-488-labeled NPs was evaluated in MCF-7 breast cancer cells over a 24-hour time course. Confocal fluorescent microscopy revealed that PLGA-PEG NPs were efficiently taken up, and the uptake reached the maximum at 24 hours. In addition, we examined the antiproliferative effects of PE-, PU-, and/or EA-loaded NPs in MCF-7 and Hs578T breast cancer cells. We found that PE, PU, and EA nanoprototypes had a 2- to 12-fold enhanced effect on cell growth inhibition compared to their free counterparts, while void NPs did not affect cell growth. PU-NPs were the most potent nanoprototype of pomegranates. Thus, PU may be the polyphenol of choice for further chemoprevention studies with pomegranate nanoprototypes. These data demonstrate that nanotechnology-enabled delivery of pomegranate polyphenols enhances their anticancer effects in breast cancer cells. Thus, pomegranate polyphenols are promising agents for nanochemoprevention of breast cancer.

  13. MO-F-CAMPUS-I-02: Accuracy in Converting the Average Breast Dose Into the Mean Glandular Dose (MGD) Using the F-Factor in Cone Beam Breast CT- a Monte Carlo Study Using Homogeneous and Quasi-Homogeneous Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Lai, C; Zhong, Y; Wang, T; Shaw, C [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To investigate the accuracy in estimating the mean glandular dose (MGD) for homogeneous breast phantoms by converting from the average breast dose using the F-factor in cone beam breast CT. Methods: EGSnrc-based Monte Carlo codes were used to estimate the MGDs. 13-cm in diameter, 10-cm high hemi-ellipsoids were used to simulate pendant-geometry breasts. Two different types of hemi-ellipsoidal models were employed: voxels in quasi-homogeneous phantoms were designed as either adipose or glandular tissue while voxels in homogeneous phantoms were designed as the mixture of adipose and glandular tissues. Breast compositions of 25% and 50% volume glandular fractions (VGFs), defined as the ratio of glandular tissue voxels to entire breast voxels in the quasi-homogeneous phantoms, were studied. These VGFs were converted into glandular fractions by weight and used to construct the corresponding homogeneous phantoms. 80 kVp x-rays with a mean energy of 47 keV was used in the simulation. A total of 109 photons were used to image the phantoms and the energies deposited in the phantom voxels were tallied. Breast doses in homogeneous phantoms were averaged over all voxels and then used to calculate the MGDs using the F-factors evaluated at the mean energy of the x-rays. The MGDs for quasi-homogeneous phantoms were computed directly by averaging the doses over all glandular tissue voxels. The MGDs estimated for the two types of phantoms were normalized to the free-in-air dose at the iso-center and compared. Results: The normalized MGDs were 0.756 and 0.732 mGy/mGy for the 25% and 50% VGF homogeneous breasts and 0.761 and 0.733 mGy/mGy for the corresponding quasi-homogeneous breasts, respectively. The MGDs estimated for the two types of phantoms were similar within 1% in this study. Conclusion: MGDs for homogeneous breast models may be adequately estimated by converting from the average breast dose using the F-factor.

  14. MO-F-CAMPUS-I-02: Accuracy in Converting the Average Breast Dose Into the Mean Glandular Dose (MGD) Using the F-Factor in Cone Beam Breast CT- a Monte Carlo Study Using Homogeneous and Quasi-Homogeneous Phantoms

    International Nuclear Information System (INIS)

    Lai, C; Zhong, Y; Wang, T; Shaw, C

    2015-01-01

    Purpose: To investigate the accuracy in estimating the mean glandular dose (MGD) for homogeneous breast phantoms by converting from the average breast dose using the F-factor in cone beam breast CT. Methods: EGSnrc-based Monte Carlo codes were used to estimate the MGDs. 13-cm in diameter, 10-cm high hemi-ellipsoids were used to simulate pendant-geometry breasts. Two different types of hemi-ellipsoidal models were employed: voxels in quasi-homogeneous phantoms were designed as either adipose or glandular tissue while voxels in homogeneous phantoms were designed as the mixture of adipose and glandular tissues. Breast compositions of 25% and 50% volume glandular fractions (VGFs), defined as the ratio of glandular tissue voxels to entire breast voxels in the quasi-homogeneous phantoms, were studied. These VGFs were converted into glandular fractions by weight and used to construct the corresponding homogeneous phantoms. 80 kVp x-rays with a mean energy of 47 keV was used in the simulation. A total of 109 photons were used to image the phantoms and the energies deposited in the phantom voxels were tallied. Breast doses in homogeneous phantoms were averaged over all voxels and then used to calculate the MGDs using the F-factors evaluated at the mean energy of the x-rays. The MGDs for quasi-homogeneous phantoms were computed directly by averaging the doses over all glandular tissue voxels. The MGDs estimated for the two types of phantoms were normalized to the free-in-air dose at the iso-center and compared. Results: The normalized MGDs were 0.756 and 0.732 mGy/mGy for the 25% and 50% VGF homogeneous breasts and 0.761 and 0.733 mGy/mGy for the corresponding quasi-homogeneous breasts, respectively. The MGDs estimated for the two types of phantoms were similar within 1% in this study. Conclusion: MGDs for homogeneous breast models may be adequately estimated by converting from the average breast dose using the F-factor

  15. Evidence that breast tissue stiffness is associated with risk of breast cancer.

    Science.gov (United States)

    Boyd, Norman F; Li, Qing; Melnichouk, Olga; Huszti, Ella; Martin, Lisa J; Gunasekara, Anoma; Mawdsley, Gord; Yaffe, Martin J; Minkin, Salomon

    2014-01-01

    Evidence from animal models shows that tissue stiffness increases the invasion and progression of cancers, including mammary cancer. We here use measurements of the volume and the projected area of the compressed breast during mammography to derive estimates of breast tissue stiffness and examine the relationship of stiffness to risk of breast cancer. Mammograms were used to measure the volume and projected areas of total and radiologically dense breast tissue in the unaffected breasts of 362 women with newly diagnosed breast cancer (cases) and 656 women of the same age who did not have breast cancer (controls). Measures of breast tissue volume and the projected area of the compressed breast during mammography were used to calculate the deformation of the breast during compression and, with the recorded compression force, to estimate the stiffness of breast tissue. Stiffness was compared in cases and controls, and associations with breast cancer risk examined after adjustment for other risk factors. After adjustment for percent mammographic density by area measurements, and other risk factors, our estimate of breast tissue stiffness was significantly associated with breast cancer (odds ratio = 1.21, 95% confidence interval = 1.03, 1.43, p = 0.02) and improved breast cancer risk prediction in models with percent mammographic density, by both area and volume measurements. An estimate of breast tissue stiffness was associated with breast cancer risk and improved risk prediction based on mammographic measures and other risk factors. Stiffness may provide an additional mechanism by which breast tissue composition is associated with risk of breast cancer and merits examination using more direct methods of measurement.

  16. Geological-geotechnical studies for siting the Superconducting Super Collider in Illinois: results of drilling large-diameter holes in 1986. Environmental geology notes

    International Nuclear Information System (INIS)

    Vaiden, R.C.; Hasek, M.J.; Gendron, C.R.; Curry, B.B.; Graese, A.M.

    1988-01-01

    The Illinois State Geological Survey (ISGS) has completed an extensive four-year exploration of the area near Fermi National Accelerator Laboratory (Fermilab) at Batavia, 30 miles west of Chicago. The comprehensive investigation was conducted to locate the most suitable site for construction and operation of the Superconducting Super Collider (SSC) - a 20-trillion electron volt (TeV) subatomic particle accelerator. Underlying the proposed site in northeastern Illinois, between 250 and 600 feet deep, are the Galena and Platteville dolomites - strong, stable, nearly impermeable bedrock. To confirm that these bedrock units are suitable for construction of the SSC, ISGS geologists designed a four-year study including test drilling, rock sampling and analysis, geophysical logging, hydrogeologic studies, and seismic exploration. Initially, the study covered parts of six counties. Subsequent research focused on successively smaller areas until the final stage of test drilling in spring 1986 concentrated on a proposed corridor for the SSC tunnel. From 1984 to 1986, thirty 3-inch-diameter test holes were drilled and more than 2 miles of bedrock core was recovered for stratigraphic description and geotechnical analysis

  17. Breast infection

    Science.gov (United States)

    Mastitis; Infection - breast tissue; Breast abscess ... must continue to breastfeed or pump to relieve breast swelling from milk production. In case if the abscess does not go away, needle aspiration under ultrasound ...

  18. Breast Diseases

    Science.gov (United States)

    ... bumps, and discharges (fluids that are not breast milk). If you have a breast lump, pain, discharge or skin irritation, see your health care provider. Minor and serious breast problems have similar ...

  19. Fibroadenoma - breast

    Science.gov (United States)

    Breast lump - fibroadenoma; Breast lump - noncancerous; Breast lump - benign ... The cause of fibroadenomas is not known. They may be related to hormones. Girls who are going through puberty and women who are ...

  20. Prospective study of growth and development in older girls and risk of benign breast disease in young women.

    Science.gov (United States)

    Berkey, Catherine S; Willett, Walter C; Frazier, A Lindsay; Rosner, Bernard; Tamimi, Rulla M; Colditz, Graham A

    2011-04-15

    In adult women with retrospective data, childhood adiposity, pubertal growth and development were associated with benign breast disease (BBD) and/or breast cancer. The authors prospectively evaluated these childhood/adolescent characteristics and BBD risk. The Growing Up Today Study (GUTS) included females, aged 9-15 years in 1996, who completed annual questionnaires through 2001, then 2003, 2005, and 2007. Participants annually/biennially provided information on menarche, height, and weight, from which the authors derived body mass index (BMI in kg/m(2) ). Peak height growth velocity (PHV in cm/year) was estimated from longitudinal data. On 2005-2007 surveys, 6899 females (18-27 years of age) reported whether a healthcare provider ever diagnosed BBD (n = 147), and whether it was confirmed by biopsy (n = 67). Logistic models investigated risk factors adjusted for age, alcohol, pregnancy, and maternal history. More childhood adiposity (odds ratio [OR], 0.91/[kg/m(2) ]; P = .04) and shorter adult height (OR, 0.93/inch shorter; P = .07) were associated with lower risk of biopsy-confirmed BBD. Girls with most rapid height growth were at increased risk (OR, 2.12; P = .09) relative to those with the slowest growth. Age at menarche was not associated (OR, 1.11/year; P = .32) nor was adult BMI (adjusted for childhood BMI: OR, 1.01/[kg/m(2) ]; P = .98); larger BMI increases (childhood to adulthood) were not protective (OR + 1.04/[kg/m(2) ]; P = .37). Among girls with maternal breast cancer, those with more rapid growth had higher risk (OR, 1.47/[cm/year]; P = .02). All estimates were age-adjusted. Increased BBD risk (likely evolving to elevated breast cancer risk) was observed in thinner girls, girls with the most rapid growth, and taller women. Contrary to expectations, later menarche age was not protective against BBD, consistent with studies that found BBD patients are not protected against breast cancer by later menarche. Copyright © 2011 American Cancer Society.

  1. Breast cancer

    Science.gov (United States)

    ... can help you know how to prevent breast cancer. Breast implants, using antiperspirants, and wearing underwire bras do not increase the risk for breast cancer. There is also no evidence of a direct ...

  2. Techniques for chamfer and taper grinding of oxide fuel pellets (LWBR Development Program)

    International Nuclear Information System (INIS)

    Johnson, R.G.R.; Allison, J.W.

    1981-10-01

    Floor mounted centerless grinding machines were adapted for shaping the edges of cylindrical oxide fuel pellets for the Light Water Breeder Reactor (LWBR) by plunge grinding. Edge configurations consisted of chamfers, either 0.015 inch x 45 0 or 0.006 inch x 45 0 , or tapers 0.150 inch long x .0025 inch deep. Grinding was done by plunging the pellet against a shaped grinding wheel which ground both the diameter to the required size and shaped the edges of the pellet. Two plunges per pellet were required to complete the operation. Separate wheels were needed for grinding either a chamfer or a taper, the set up was adjustable to vary the size of the chamfer or taper as needed. The set up also had the flexibility to accommodate the multiple pellet lengths and diameters required by the LWBR design. Tight manufacturing tolerances in the chamfer and taper dimensions required the use of dimensional control charts and statistical sampling plans as process controls

  3. [Management of breast cancer in a woman with breast implants].

    Science.gov (United States)

    Remacle, S; Lifrange, E; Nizet, J-L

    2015-01-01

    The incidence of breast cancer, currently one woman on eight, also concerns patients who underwent augmentation surgery. Breast implants have already been the subject of numerous publications concerning the risk of inducing breast cancer or of delaying its diagnosis; however, no significant causal relationship has been established. The purpose of this article is to assess the diagnostic and therapeutic consequences when breast cancer is identified in a patient with breast implants.

  4. The role of cone-beam breast-CT for breast cancer detection relative to breast density

    Energy Technology Data Exchange (ETDEWEB)

    Wienbeck, Susanne; Uhlig, Johannes; Fintel, Eva von; Stahnke, Vera; Lotz, Joachim [University Medical Center Goettingen, Institute for Diagnostic and Interventional Radiology, Goettingen (Germany); Luftner-Nagel, Susanne; Fischer, Uwe [Diagnostic Breast Center Goettingen, Goettingen (Germany); Zapf, Antonia [University Medical Center Goettingen, Department of Medical Statistics, Goettingen (Germany); Surov, Alexey [University of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany)

    2017-12-15

    To evaluate the impact of breast density on the diagnostic accuracy of non-contrast cone-beam breast computed tomography (CBBCT) in comparison to mammography for the detection of breast masses. A retrospective study was conducted from August 2015 to July 2016. Fifty-nine patients (65 breasts, 112 lesions) with BI-RADS, 5th edition 4 or 5 assessment in mammography and/or ultrasound of the breast received an additional non-contrast CBBCT. Independent double blind reading by two radiologists was performed for mammography and CBBCT imaging. Sensitivity, specificity and AUC were compared between the modalities. Breast lesions were histologically examined in 85 of 112 lesions (76%). The overall sensitivity for CBBCT (reader 1: 91%, reader 2: 88%) was higher than in mammography (both: 68%, p<0.001), and also for the high-density group (p<0.05). The specificity and AUC was higher for mammography in comparison to CBBCT (p<0.05 and p<0.001). The interobserver agreement (ICC) between the readers was 90% (95% CI: 86-93%) for mammography and 87% (95% CI: 82-91%) for CBBCT. Compared with two-view mammography, non-contrast CBBCT has higher sensitivity, lower specificity, and lower AUC for breast mass detection in both high and low density breasts. (orig.)

  5. Investigating the prediction value of multiparametric magnetic resonance imaging at 3 T in response to neoadjuvant chemotherapy in breast cancer

    International Nuclear Information System (INIS)

    Minarikova, Lenka; Bogner, Wolfgang; Zaric, Olgica; Trattnig, Siegfried; Gruber, Stephan; Pinker, Katja; Valkovic, Ladislav; Bago-Horvath, Zsuzsanna; Bartsch, Rupert; Helbich, Thomas H.

    2017-01-01

    To explore the predictive value of parameters derived from diffusion-weighted imaging (DWI) and contrast-enhanced (CE)-MRI at different time-points during neoadjuvant chemotherapy (NACT) in breast cancer. Institutional review board approval and written, informed consent from 42 breast cancer patients were obtained. The patients were investigated before and at three different time-points during neoadjuvant chemotherapy (NACT) using tumour diameter and volume from CE-MRI and ADC values obtained from drawn 2D and segmented 3D regions of interest. Prediction of pathologic complete response (pCR) was evaluated using the area under the curve (AUC) of receiver operating characteristic analysis. There was no significant difference between pathologic complete response and non-pCR in baseline size measures (p > 0.39). Diameter change was significantly different in pCR (p < 0.02) before the mid-therapy point. The best predictor was lesion diameter change observed before mid-therapy (AUC = 0.93). Segmented volume was not able to differentiate between pCR and non-pCR at any time-point. The ADC values from 3D-ROI were not significantly different from 2D data (p = 0.06). The best AUC (0.79) for pCR prediction using DWI was median ADC measured before mid-therapy of NACT. The results of this study should be considered in NACT monitoring planning, especially in MRI protocol designing and time point selection. (orig.)

  6. Investigating the prediction value of multiparametric magnetic resonance imaging at 3 T in response to neoadjuvant chemotherapy in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Minarikova, Lenka; Bogner, Wolfgang; Zaric, Olgica; Trattnig, Siegfried; Gruber, Stephan [Medical University of Vienna, High-field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna (Austria); Pinker, Katja [Medical University of Vienna, Division of Molecular and Gender Imaging, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Memorial Sloan-Kettering Cancer Center, Molecular Imaging and Therapy Service, New York, NY (United States); Valkovic, Ladislav [Medical University of Vienna, High-field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna (Austria); Slovak Academy of Sciences, Department of Imaging Methods, Institute of Measurement Science, Bratislava (Slovakia); University of Oxford, John Radcliffe Hospital, Oxford Centre for Clinical Magnetic Resonance Research, Oxford (United Kingdom); Bago-Horvath, Zsuzsanna [Medical University of Vienna, Department of Pathology, Comprehensive Cancer Center, Vienna (Austria); Bartsch, Rupert [Medical University of Vienna, Clinical Division of Oncology, Department of Medicine I, Vienna (Austria); Helbich, Thomas H. [Medical University of Vienna, Division of Molecular and Gender Imaging, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria)

    2017-05-15

    To explore the predictive value of parameters derived from diffusion-weighted imaging (DWI) and contrast-enhanced (CE)-MRI at different time-points during neoadjuvant chemotherapy (NACT) in breast cancer. Institutional review board approval and written, informed consent from 42 breast cancer patients were obtained. The patients were investigated before and at three different time-points during neoadjuvant chemotherapy (NACT) using tumour diameter and volume from CE-MRI and ADC values obtained from drawn 2D and segmented 3D regions of interest. Prediction of pathologic complete response (pCR) was evaluated using the area under the curve (AUC) of receiver operating characteristic analysis. There was no significant difference between pathologic complete response and non-pCR in baseline size measures (p > 0.39). Diameter change was significantly different in pCR (p < 0.02) before the mid-therapy point. The best predictor was lesion diameter change observed before mid-therapy (AUC = 0.93). Segmented volume was not able to differentiate between pCR and non-pCR at any time-point. The ADC values from 3D-ROI were not significantly different from 2D data (p = 0.06). The best AUC (0.79) for pCR prediction using DWI was median ADC measured before mid-therapy of NACT. The results of this study should be considered in NACT monitoring planning, especially in MRI protocol designing and time point selection. (orig.)

  7. Human in-vivo 31P MR spectroscopy of benign and malignant breast tumors

    International Nuclear Information System (INIS)

    Park, Jeong Mi; Park, Jae Hyung

    2001-01-01

    To assess the potential clinical utility of in-vivo 31P magnetic resonance spectroscopy (MRS) in patients with various malignant and benign breast lesions. Seventeen patients with untreated primary malignant breast lesions (group I), eight patients with untreated benign breast lesions (group II) and seven normal breasts (group III) were included in this study. In-vivo 31P MRS was performed using a 1.5 Tesla MR scanner. Because of the characteristics of the coil, the volume of the tumor had to exceed 12 cc (3x2x2 cm), with a superoinferior diameter at least 3 cm. Mean and standard deviations of each metabolite were calculated and metabolite ratios, such as PME/PCr, PDE/PCr, T-ATP/PCr and PCr/T-ATP were calculated and statistically analyzed. Significant differences in PME were noted between groups I and III (p=0.0213), and between groups II and III (p=0.0213). The metabolite ratios which showed significant differences were PME/PCr (between groups II and III) (p=0.0201), PDE/PCr (between groups I and III, and between groups II and III) (p=0.0172), T-ATP/PCr (between groups II and III) (p=0.0287), and PCr/T-ATP (between groups II and III) (p=0.0287). There were no significant parameters between groups I and II. In-vivo 31P MRS is not helpful for establishing a differential diagnosis between benign and malignant breast lesions, at least with relatively large lesions greater than 3 cm in one or more dimensions

  8. Breast density does not impact the ability of Videssa® Breast to detect breast cancer in women under age 50.

    Directory of Open Access Journals (Sweden)

    David E Reese

    Full Text Available Breast density is associated with reduced imaging resolution in the detection of breast cancer. A biochemical approach that is not affected by density would provide an important tool to healthcare professionals who are managing women with dense breasts and suspicious imaging findings. Videssa® Breast is a combinatorial proteomic biomarker assay (CPBA, comprised of Serum Protein Biomarkers (SPB and Tumor Associated Autoantibodies (TAAb integrated with patient-specific clinical data to produce a diagnostic score that reliably detects breast cancer (BC as an adjunctive tool to imaging. The performance of Videssa® Breast was evaluated in the dense (a and b and non-dense (c and d groups in a population of n = 545 women under age 50. The sensitivity and specificity in the dense breast group were calculated to be 88.9% and 81.2%, respectively, and 92.3% and 86.6%, respectively, for the non-dense group. No significant differences were observed in the sensitivity (p = 1.0 or specificity (p = 0.18 between these groups. The NPV was 99.3% and 99.1% in non-dense and dense groups, respectively. Unlike imaging, Videssa® Breast does not appear to be impacted by breast density; it can effectively detect breast cancer in women with dense and non-dense breasts alike. Thus, Videssa® Breast provides a powerful tool for healthcare providers when women with dense breasts present with challenging imaging findings. In addition, Videssa® Breast provides assurance to women with dense breasts that they do not have breast cancer, reducing further anxiety in this higher risk patient population.

  9. Diameter Control and Photoluminescence of ZnO Nanorods from Trialkylamines

    Directory of Open Access Journals (Sweden)

    Tamar Andelman

    2007-01-01

    Full Text Available A novel solution method to control the diameter of ZnO nanorods is reported. Small diameter (2-3 nm nanorods were synthesized from trihexylamine, and large diameter (50–80 nm nanorods were synthesized by increasing the alkyl chain length to tridodecylamine. The defect (green emission of the photoluminescence (PL spectra of the nanorods varies with diameter, and can thus be controlled by the diameter control. The small ZnO nanorods have strong green emission, while the large diameter nanorods exhibit a remarkably suppressed green band. We show that this observation supports surface oxygen vacancies as the defect that gives rise to the green emission.

  10. High quality single atomic layer deposition of hexagonal boron nitride on single crystalline Rh(111) four-inch wafers

    Energy Technology Data Exchange (ETDEWEB)

    Hemmi, A.; Bernard, C.; Cun, H.; Roth, S.; Klöckner, M.; Kälin, T.; Osterwalder, J.; Greber, T., E-mail: greber@physik.uzh.ch [Physik-Institut, Universität Zürich, CH-8057 Zürich (Switzerland); Weinl, M.; Gsell, S.; Schreck, M. [Institut für Physik, Universität Augsburg, D-86135 Augsburg (Germany)

    2014-03-15

    The setup of an apparatus for chemical vapor deposition (CVD) of hexagonal boron nitride (h-BN) and its characterization on four-inch wafers in ultra high vacuum (UHV) environment is reported. It provides well-controlled preparation conditions, such as oxygen and argon plasma assisted cleaning and high temperature annealing. In situ characterization of a wafer is accomplished with target current spectroscopy. A piezo motor driven x-y stage allows measurements with a step size of 1 nm on the complete wafer. To benchmark the system performance, we investigated the growth of single layer h-BN on epitaxial Rh(111) thin films. A thorough analysis of the wafer was performed after cutting in atmosphere by low energy electron diffraction, scanning tunneling microscopy, and ultraviolet and X-ray photoelectron spectroscopies. The apparatus is located in a clean room environment and delivers high quality single layers of h-BN and thus grants access to large area UHV processed surfaces, which had been hitherto restricted to expensive, small area single crystal substrates. The facility is versatile enough for customization to other UHV-CVD processes, e.g., graphene on four-inch wafers.

  11. Breast lump

    Science.gov (United States)

    ... with milk). These cysts can occur with breastfeeding. Breast abscess . These typically occur if you are breastfeeding or ... Breast infections are treated with antibiotics. Sometimes a breast abscess needs to be drained with a needle or ...

  12. Breast cancer imaging

    International Nuclear Information System (INIS)

    Funke, M.; Villena, C.

    2008-01-01

    Advances in female breast imaging have substantially influenced the diagnosis, therapy, and prognosis of breast cancer in the past few years. Mammography using conventional or digital technique is considered the gold standard for the early detection of breast cancer. Other modalities such as breast ultrasound and contrast-enhanced magnetic resonance imaging of the breast play an important role in diagnostic imaging, staging, and follow-up of breast cancer. Percutaneous needle biopsy is a faster, less invasive, and more cost-effective method than surgical biopsy for verifying the histological diagnosis. New methods such as breast tomosynthesis, contrast-enhanced mammography, and positron emission tomography promise to further improve breast imaging. Further studies are mandatory to adapt these new methods to clinical needs and to evaluate their performance in clinical practice. (orig.) [de

  13. Inferring diameters of spheres and cylinders using interstitial water.

    Science.gov (United States)

    Herrera, Sheryl L; Mercredi, Morgan E; Buist, Richard; Martin, Melanie

    2018-06-04

    Most early methods to infer axon diameter distributions using magnetic resonance imaging (MRI) used single diffusion encoding sequences such as pulsed gradient spin echo (SE) and are thus sensitive to axons of diameters > 5 μm. We previously simulated oscillating gradient (OG) SE sequences for diffusion spectroscopy to study smaller axons including the majority constituting cortical connections. That study suggested the model of constant extra-axonal diffusion breaks down at OG accessible frequencies. In this study we present data from phantoms to test a time-varying interstitial apparent diffusion coefficient. Diffusion spectra were measured in four samples from water packed around beads of diameters 3, 6 and 10 μm; and 151 μm diameter tubes. Surface-to-volume ratios, and diameters were inferred. The bead pore radii estimates were 0.60±0.08 μm, 0.54±0.06 μm and 1.0±0.1 μm corresponding to bead diameters ranging from 2.9±0.4 μm to 5.3±0.7 μm, 2.6±0.3 μm to 4.8±0.6 μm, and 4.9±0.7 μm to 9±1 μm. The tube surface-to-volume ratio estimate was 0.06±0.02 μm -1 corresponding to a tube diameter of 180±70 μm. Interstitial models with OG inferred 3-10 μm bead diameters from 0.54±0.06 μm to 1.0±0.1 μm pore radii and 151 μm tube diameters from 0.06±0.02 μm -1 surface-to-volume ratios.

  14. Bilateral breast carcinoma

    International Nuclear Information System (INIS)

    Kim, Eung Jo; Oh, Ki Keun

    1990-01-01

    We evaluate 311 breast cancer patients admitted to Yong Dong Severance Hospital Between October 1st 1985 and July 31th 1989, and were able to obtain the following conclusions. 1) There were 14(4.5%) bilateral breast cancers among the 311 confirmed breast cancers. 2) Among the bilateral breast cancers, 5(31%) were synchronous and 9(69%) metachronous. 3) Average interval between the first and the second breast cancer in metachronous cancers was 3.8 year(1-15 years). 4) Bilateral breast cancer was most prevalent in the fifth decade (6/14) with the mean age of 47 years. 5) Film mammogram and sonomammogram showed findings of typical breast malignancies. There was no additional specific findings for each cancer in bilateral breast cancers which was different from unilateral cancers. Therefor, in the patients with unilateral breast cancer, possibility of the second lesion in the contralateral side must be considered and a close follow up observation should be done for at least 3 years

  15. Hypofractionated Whole-Breast Radiation Therapy: Does Breast Size Matter?

    International Nuclear Information System (INIS)

    Hannan, Raquibul; Thompson, Reid F.; Chen Yu; Bernstein, Karen; Kabarriti, Rafi; Skinner, William; Chen, Chin C.; Landau, Evan; Miller, Ekeni; Spierer, Marnee; Hong, Linda; Kalnicki, Shalom

    2012-01-01

    Purpose: To evaluate the effects of breast size on dose-volume histogram parameters and clinical toxicity in whole-breast hypofractionated radiation therapy using intensity modulated radiation therapy (IMRT). Materials and Methods: In this retrospective study, all patients undergoing breast-conserving therapy between 2005 and 2009 were screened, and qualifying consecutive patients were included in 1 of 2 cohorts: large-breasted patients (chest wall separation >25 cm or planning target volume [PTV] >1500 cm 3 ) (n=97) and small-breasted patients (chest wall separation 3 ) (n=32). All patients were treated prone or supine with hypofractionated IMRT to the whole breast (42.4 Gy in 16 fractions) followed by a boost dose (9.6 Gy in 4 fractions). Dosimetric and clinical toxicity data were collected and analyzed using the R statistical package (version 2.12). Results: The mean PTV V95 (percentage of volume receiving >= 95% of prescribed dose) was 90.18% and the mean V105 percentage of volume receiving >= 105% of prescribed dose was 3.55% with no dose greater than 107%. PTV dose was independent of breast size, whereas heart dose and maximum point dose to skin correlated with increasing breast size. Lung dose was markedly decreased in prone compared with supine treatments. Radiation Therapy Oncology Group grade 0, 1, and 2 skin toxicities were noted acutely in 6%, 69%, and 25% of patients, respectively, and at later follow-up (>3 months) in 43%, 57%, and 0% of patients, respectively. Large breast size contributed to increased acute grade 2 toxicity (28% vs 12%, P=.008). Conclusions: Adequate PTV coverage with acceptable hot spots and excellent sparing of organs at risk was achieved by use of IMRT regardless of treatment position and breast size. Although increasing breast size leads to increased heart dose and maximum skin dose, heart dose remained within our institutional constraints and the incidence of overall skin toxicity was comparable to that reported in the

  16. Measuring Electrospun Nanofibre Diameter: a Novel Approach

    International Nuclear Information System (INIS)

    Ziabari, M.; Mottaghitalab, V.; Haghi, A. K.; McGovern, S. T.

    2008-01-01

    A new method based on image analysis for electrospun nanofibre diameter measurement is presented. First, the SEM micrograph of the nanofibre web obtained by electrospinning process is converted to binary image using local thresholding method. In the next step, skeleton and distance transformed image are generated. Then, the intersection points which bring about untrue measurements are identified and removed from the skeleton. Finally, the resulting skeleton and distance transformed image are used to determine fibre diameter. The method is evaluated by a simulated image with known characteristics generated by ?-randomness procedure. The results indicate that this approach is successful in making fast, accurate automated measurements of electrospun fibre diameters. (cross-disciplinary physics and related areas of science and technology)

  17. Performance of patch repaired composite panels under fatigue loads

    International Nuclear Information System (INIS)

    Darwish, Feras H.; Hamoush, S.; Shivakumar, K.

    2006-01-01

    This paper evaluates the performance of bonded patch-scarf repairs of full scale laminated composite panels under cyclic load conditions. Nondestructive testing to characterize the quality of repairs and destructive testing to evaluate the performance of repaired panels were used in this study. Carbon/Epoxy prepreg material used was used to lay up six-ply (12 in. x 27 in. /305x686mm) (-60/60/0) s quasi-isotropic laminates. 7-ply scarf repair with a gradient of 0.5 inch (12.7mm) per layer was used to perform the repair of a damaged zone. The patch consisted of 7.5 inches (190mm) diameter adhesive film, 1 inch (25.4mm) diameter filler ply at 90fiber orientation, and six plies (2-7 inches (51-178mm) diameter) to match the lay-up of the parent material. The study was extended to include defective repairs. The defect was engineered by inserting a 1 inch (25.4 mm) circular Teflon flaw between the fifth and sixth layers of the patch. A total of 28 panels were prepared and divided into five categories: (1) three pristine panels (undamaged parental materials); (2) three damaged panels (1-inch-centered-hole); (3) two repaired panels with wrong fiber orientation; (4) nine good repaired panels, and (5) eleven defective repair panels (1 inch flaw). A nondestructive evaluation to check the conditions of the repairs was performed on most of the tested panels that include the pulse-echo C-scan and pseudo through transmission air coupled and water coupled C-scan. Based on the results of the experimental evaluation of this study, good repair restored 95% of the tensile strength while defective repair restored 90% of the tensile strength of the pristine panels. Under fatigue loading, panels repaired with a 1 inch delamination flaw within the patch layers showed a major reduction in fatigue life compared to the good repair panels under similar loading conditions. (author)

  18. Breast lift

    Science.gov (United States)

    ... and areola may be moved. Sometimes, women have breast augmentation (enlargement with implants) when they have a breast lift. Why the ... MD, FACS, general surgery practice specializing in breast cancer, Virginia Mason Medical Center, Seattle, WA. Also reviewed ...

  19. Breast metastasis from cutaneous malignant melanoma mimicking a breast cancer.

    Science.gov (United States)

    Maniglio, Marina; Capalbo, Emanuela; Viganò, Sara; Trecate, Giovanna; Scaperrotta, Gianfranco Paride; Panizza, Pietro

    2015-06-25

    Breast metastases are very uncommon, either from solid tumors or malignant melanoma. We present the case of a 42-year-old woman with a history of cutaneous melanoma of the shoulder excised 21 years ago. She presented with a palpable lump in the upper outer quadrant of the right breast. Ultrasound demonstrated a solid mass within a cystic lesion. A core biopsy was taken and first histology reported a poorly differentiated primary breast cancer suspected to be triple negative. MRI detected a satellite lesion in the same breast, a focus of suspected enhancement in the other breast, and the extramammary finding of an enhancing pulmonary lesion. Staging computed tomography detected widespread metastases to the lungs, brain, subcutaneous left shoulder, liver, pancreas, and hepatorenal recess. A core biopsy was taken from the left breast lesion and the previous slides were reviewed; histopathology and immunohistochemistry were in keeping with metastasis from melanoma. The possibility of a metastatic lesion to the breast should be taken into account in any patient presenting with a breast lump and a previous history of melanoma. Breast involvement cannot be considered an isolated finding, as it might be the first manifestation of widespread disease.

  20. Defense Standardization Program Journal. April/September 2012

    Science.gov (United States)

    2012-01-01

    were magnified. In 1905, a committee of the National Fire Protection Association established a national standard for the diameter and threads per inch...for fire hydrants and hose couplings. The standard specifies that fire hydrants have 2.5-inch hose connections with 7.5 threads per inch and that...dsp.dla.mil I Field of view, lens material haze, luminous transmittance, and lens abrasion resistance (APR) I Communications (APR) I Fogging (APR

  1. Non-Surgical Breast-Conserving Treatment (KORTUC-BCT Using a New Radiosensitization Method (KORTUC II for Patients with Stage I or II Breast Cancer

    Directory of Open Access Journals (Sweden)

    Yasuhiro Ogawa

    2015-11-01

    Full Text Available The purpose of the present study was to establish a non-surgical breast-conserving treatment (BCT using KORTUC II radiosensitization treatment. A new radiosensitizing agent containing 0.5% hydrogen peroxide and 0.83% sodium hyaluronate (a CD44 ligand has been developed for intra-tumoral injection into various tumors. This new method, named KORTUC II, was approved by our local ethics committee for the treatment of breast cancer and metastatic lymph nodes. A total of 72 early-stage breast cancer patients (stage 0, 1 patient; stage I, 23; stage II, 48 were enrolled in the KORTUC II trial after providing fully informed consent. The mean age of the patients was 59.7 years. A maximum of 6 mL (usually 3 mL for tumors of less than approximately 3 cm in diameter of the agent was injected into breast tumor tissue twice a week under ultrasonographic guidance. For radiotherapy, hypofraction radiotherapy was administered using a tangential fields approach including an ipsilateral axillary region and field-in-field method; the energy level was 4 MV, and the total radiation dose was 44 Gy administered as 2.75 Gy/fraction. An electron boost of 3 Gy was added three times. Treatment was well tolerated with minimal adverse effects in all 72 patients. No patients showed any significant complications other than mild dermatitis. A total of 24 patients under 75 years old with stage II breast cancer underwent induction chemotherapy (EC and/or taxane prior to KORTUC II treatment, and 58 patients with estrogen receptor-positive tumors also received hormonal therapy following KORTUC II. The mean duration of follow-up as of the end of September 2014 was 51.1 months, at which time 68 patients were alive without any distant metastases. Only one patient had local recurrence and died of cardiac failure at 6.5 years. Another one patient had bone metastases. For two of the 72 patients, follow-up ended after several months following KORTUC II treatment. In conclusion, non

  2. Breast cancer screening with digital breast tomosynthesis.

    Science.gov (United States)

    Skaane, Per

    2017-01-01

    To give an overview of studies comparing full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) in breast cancer screening. The implementation of tomosynthesis in breast imaging is rapidly increasing world-wide. Experimental clinical studies of relevance for DBT screening have shown that tomosynthesis might have a great potential in breast cancer screening, although most of these retrospective reading studies are based on small populations, so that final conclusions are difficult to draw from individual reports. Several retrospective studies and three prospective trials on tomosynthesis in breast cancer screening have been published so far, confirming the great potential of DBT in mammography screening. The main results of these screening studies are presented. The retrospective screening studies from USA have all shown a significant decrease in the recall rate using DBT as adjunct to mammography. Most of these studies have also shown an increase in the cancer detection rate, and the non-significant results in some studies might be explained by a lack of statistical power. All the three prospective European trials have shown a significant increase in the cancer detection rate. The retrospective and the prospective screening studies comparing FFDM and DBT have all demonstrated that tomosynthesis has a great potential for improving breast cancer screening. DBT should be regarded as a better mammogram that could improve or overcome limitations of the conventional mammography, and tomosynthesis might be considered as the new technique in the next future of breast cancer screening.

  3. Testing of one-inch UF{sub 6} cylinder valves under simulated fire conditions

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, P.G. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    Accurate computational models which predict the behavior of UF{sub 6} cylinders exposed to fires are required to validate existing firefighting and emergency response procedures. Since the cylinder valve is a factor in the containment provided by the UF{sub 6} cylinder, its behavior under fire conditions has been a necessary assumption in the development of such models. Consequently, test data is needed to substantiate these assumptions. Several studies cited in this document provide data related to the behavior of a 1-inch UF{sub 6} cylinder valve in fire situations. To acquire additional data, a series of tests were conducted at the Paducah Gaseous Diffusion Plant (PGDP) under a unique set of test conditions. This document describes this testing and the resulting data.

  4. Accelerated partial breast irradiation using intensity-modulated radiotherapy technique compared to whole breast irradiation for patients aged 70 years or older: subgroup analysis from a randomized phase 3 trial.

    Science.gov (United States)

    Meattini, Icro; Saieva, Calogero; Marrazzo, Livia; Di Brina, Lucia; Pallotta, Stefania; Mangoni, Monica; Meacci, Fiammetta; Bendinelli, Benedetta; Francolini, Giulio; Desideri, Isacco; De Luca Cardillo, Carla; Scotti, Vieri; Furfaro, Ilaria Francesca; Rossi, Francesca; Greto, Daniela; Bonomo, Pierluigi; Casella, Donato; Bernini, Marco; Sanchez, Luis; Orzalesi, Lorenzo; Simoncini, Roberta; Nori, Jacopo; Bianchi, Simonetta; Livi, Lorenzo

    2015-10-01

    The purpose of this study was to report the efficacy and the safety profile on the subset of selected early breast cancer (BC) patients aged 70 years or older from a single-center phase 3 trial comparing whole breast irradiation (WBI) to accelerated partial breast irradiation (APBI) using intensity-modulated radiation therapy technique. Between 2005 and 2013, 520 patients aged more than 40 years old were enrolled and randomly assigned to receive either WBI or APBI in a 1:1 ratio. Eligible patients were women with early BC (maximum diameter 2.5 cm) suitable for breast conserving surgery. This study is registered with ClinicalTrials.gov, NCT02104895. A total of 117 patients aged 70 years or more were analyzed (58 in the WBI arm, 59 in the APBI arm). At a median follow-up of 5-years (range 3.4-7.0), the ipsilateral breast tumor recurrence (IBTR) rate was 1.9 % in both groups. No significant difference between the two groups was identified (log-rank test p = 0.96). The 5-year disease-free survival (DFS) rates in the WBI group and APBI group were 6.1 and 1.9 %, respectively (p = 0.33). The APBI group presented significantly better results in terms of acute skin toxicity, considering both any grade (p = 0.0001) and grade 2 or higher (p = 0.0001). Our subgroup analyses showed a very low rate and no significant difference in terms of IBTR, using both WBI and APBI. A significant impact on patients compliance in terms of acute and early late toxicity was shown, which could translate in a consistent improvement of overall quality of life.

  5. Pathological features of Breast Cancer seen in Northwestern Tanzania: a nine years retrospective study

    Directory of Open Access Journals (Sweden)

    Manyama Mange M

    2011-06-01

    Full Text Available Abstract Background Breast cancer is more common in Western Countries compared to African populations. However in African population, it appears that the disease tends to be more aggressive and occurring at a relatively young age at the time of presentation. The aim of this study was to describe the trend of Breast Cancer in Northwestern Tanzania. Methods This was a retrospective study which involved all cases of breast cancer diagnosed histologically at Bugando Medical Center from 2002 to 2010. Histological results and slides were retrieved from the records in the Pathology department, clinical information and demographic data for patients were retrieved from surgical wards and department of medical records. Histology slides were re-evaluated for the histological type, grade (By modified Bloom-Richardson score, and presence of necrosis and skin involvement. Data was entered and analyzed by SPSS computer software version 15. Findings There were 328 patients histologically confirmed to have breast cancer, the mean age at diagnosis was 48.7 years (+/- 13.1. About half of the patients (52.4% were below 46 years of age, and this group of patients had significantly higher tendency for lymph node metastasis (p = 0.012. The tumor size ranged from 1 cm to 18 cm in diameter with average (mean of 5.5 cm (+/- 2.5, and median size of 6 cm. Size of the tumor (above 6 cm in diameter and presence of necrosis within the tumor was significantly associated with high rate of lymph node metastasis (p = 0.000. Of all patients, 64% were at clinical stage III (specifically IIIB and 70.4% had lymph node metastasis at the time of diagnosis. Only 4.3% of the patients were in clinical stage I at the time of diagnosis. Majority of the patients had invasive ductal carcinoma (91.5% followed by mucinous carcinoma (5.2%, Invasive lobular carcinoma (3% and in situ ductal carcinoma (0.3%. In all patients, 185 (56.4% had tumor with histological grade 3. Conclusion Breast cancer

  6. Stages of Breast Cancer

    Science.gov (United States)

    ... of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Cancer Treatment (PDQ®)–Patient Version General Information About Breast Cancer Go to Health Professional Version Key Points Breast ...

  7. Nuclear medicine in breast cancer diagnostics: Primary tumor and lymphatic metastasis

    Science.gov (United States)

    Sinilkin, I.; Medvedeva, A.; Chernov, V.; Slonimskaya, E.; Zelchan, R.; Bragina, O.

    2017-09-01

    The purpose of the study: to assess the possibility of using nuclear medicine techniques at the stages of diagnosis and treatment of breast cancer. Materials and Methods: The study included 290 patients with breast cancer and 70 patients with benign breast tumors. The study was used as a radiopharmaceutical 99mTc-MIBI, 199Tl for imaging tumors and colloid 99mTc-Aloteh for visualization sentinel lymph nodes (SLN), colloid was injected peritumoral in four points to 80 MBq one day prior to the planned operation. Results: The sensitivity of SPECT using both 99mTc-MIBI and 199Tl for breast cancer detection was shown to be rather high, being 98.5% and 98%, respectively. It should be noted that the sensitivity of SPECT in detection of small tumors (less than 1 cm in diameter) and multicentric tumors was not high irrespective of the radioisotope used (60% and 65% with 99mTc-MIBI and 65% and 59% with 199Tl, respectively). The difference in the sensitivity was found between 99mTc-MIBI and 199T for the detection of regional lymph node metastasis (91% vs 70%). SLN were detected in 31 patients. The most commonly SLN were defined in the axillary region of 96.7%. In 22 (70.9%) patients there was no metastasis SLN. The sensitivity of the method was 91.2%, specificity of 100%. Conclusion: The specificity of SPECT with 199Tl was higher than that with 99mTc-MIBI. The data obtained show that SPECT with 199Tl can be recommended for its use as an additional breast cancer detection method in cases when other imaging techniques and histological findings are not accurate enough. The clinical study of 99mTc-Aloteh, a new radiopharmaceutical agent, has shown that the studied colloid has high uptake level in SLN and can be successfully used for visualization of SLN in patients with breast cancer.

  8. Should breast density influence patient selection for breast-conserving surgery?

    Science.gov (United States)

    Kapoor, Nimmi S; Eaton, Anne; King, Tari A; Patil, Sujata; Stempel, Michelle; Morris, Elizabeth; Brogi, Edi; Morrow, Monica

    2013-02-01

    In a previous study of the relationship between breast density and primary tumor features, we observed a higher mastectomy rate in patients with extremely dense breasts. Here we examine possible reasons for this finding. Data were obtained from a prospectively maintained database of 1,056 invasive breast cancer patients from January 2005 to June 2007. Mammographic density was assigned by Breast Imaging-Reporting and Data System (BI-RADS) classification. Initial and final surgical procedures, and patient and tumor variables were recorded. Breast-conserving surgery (BCS) was attempted in 758 patients (72 %), 385 (51 %) of whom had preoperative magnetic resonance imaging (MRI). Initial BCS was less common among patients with the highest (BI-RADS 4) breast density compared to patients with less-dense breasts (52 vs. 74 %; p mastectomy compared to patients with less-dense breasts. After initial BCS, 387 patients (51 %) had positive shaved margins, 96 (25 %) of whom converted to mastectomy. MRI did not correlate with the rate of positive margins overall or among those with dense breasts. Adjusting for clinical and pathologic variables, density did not predict margin status or conversion to mastectomy. In a multivariate model, age, histologic grade, extensive intraductal component, and multicentricity/multifocality were independently associated with conversion to mastectomy. Density alone seems to influence the decision to proceed with initial mastectomy. When BCS was attempted, breast density was not associated with positive margins or conversion to mastectomy. A benefit of MRI in decreasing positive margins was not observed. These data do not support the use of breast density as a selection criterion for BCS.

  9. A compact, discrete CsI(Tl) scintillator/Si photodiode gamma camera for breast cancer imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, Gregory J. [Univ. of California, Berkeley, CA (United States)

    2000-01-01

    Recent clinical evaluations of scintimammography (radionuclide breast imaging) are promising and suggest that this modality may prove a valuable complement to X-ray mammography and traditional breast cancer detection and diagnosis techniques. Scintimammography, however, typically has difficulty revealing tumors that are less than 1 cm in diameter, are located in the medial part of the breast, or are located in the axillary nodes. These shortcomings may in part be due to the use of large, conventional Anger cameras not optimized for breast imaging. In this thesis I present compact single photon camera technology designed specifically for scintimammography which strives to alleviate some of these limitations by allowing better and closer access to sites of possible breast tumors. Specific applications are outlined. The design is modular, thus a camera of the desired size and geometry can be constructed from an array (or arrays) of individual modules and a parallel hole lead collimator for directional information. Each module consists of: (1) an array of 64 discrete, optically-isolated CsI(Tl) scintillator crystals 3 x 3 x 5 mm3 in size, (2) an array of 64 low-noise Si PIN photodiodes matched 1-to-1 to the scintillator crystals, (3) an application-specific integrated circuit (ASIC) that amplifies the 64 photodiode signals and selects the signal with the largest amplitude, and (4) connectors and hardware for interfacing the module with a motherboard, thereby allowing straightforward computer control of all individual modules within a camera.

  10. A compact, discrete CsI(Tl) scintillator/Si photodiode gamma camera for breast cancer imaging

    International Nuclear Information System (INIS)

    Gruber, Gregory J.

    2000-01-01

    Recent clinical evaluations of scintimammography (radionuclide breast imaging) are promising and suggest that this modality may prove a valuable complement to X-ray mammography and traditional breast cancer detection and diagnosis techniques. Scintimammography, however, typically has difficulty revealing tumors that are less than 1 cm in diameter, are located in the medial part of the breast, or are located in the axillary nodes. These shortcomings may in part be due to the use of large, conventional Anger cameras not optimized for breast imaging. In this thesis I present compact single photon camera technology designed specifically for scintimammography which strives to alleviate some of these limitations by allowing better and closer access to sites of possible breast tumors. Specific applications are outlined. The design is modular, thus a camera of the desired size and geometry can be constructed from an array (or arrays) of individual modules and a parallel hole lead collimator for directional information. Each module consists of: (1) an array of 64 discrete, optically-isolated CsI(Tl) scintillator crystals 3 x 3 x 5 mm 3 in size, (2) an array of 64 low-noise Si PIN photodiodes matched 1-to-1 to the scintillator crystals, (3) an application-specific integrated circuit (ASIC) that amplifies the 64 photodiode signals and selects the signal with the largest amplitude, and (4) connectors and hardware for interfacing the module with a motherboard, thereby allowing straightforward computer control of all individual modules within a camera

  11. Quantitative Maximum Shear-Wave Stiffness of Breast Masses as a Predictor of Histopathologic Severity.

    Science.gov (United States)

    Berg, Wendie A; Mendelson, Ellen B; Cosgrove, David O; Doré, Caroline J; Gay, Joel; Henry, Jean-Pierre; Cohen-Bacrie, Claude

    2015-08-01

    The objective of our study was to compare quantitative maximum breast mass stiffness on shear-wave elastography (SWE) with histopathologic outcome. From September 2008 through September 2010, at 16 centers in the United States and Europe, 1647 women with a sonographically visible breast mass consented to undergo quantitative SWE in this prospective protocol; 1562 masses in 1562 women had an acceptable reference standard. The quantitative maximum stiffness (termed "Emax") on three acquisitions was recorded for each mass with the range set from 0 (very soft) to 180 kPa (very stiff). The median Emax and interquartile ranges (IQRs) were determined as a function of histopathologic diagnosis and were compared using the Mann-Whitney U test. We considered the impact of mass size on maximum stiffness by performing the same comparisons for masses 9 mm or smaller and those larger than 9 mm in diameter. The median patient age was 50 years (mean, 51.8 years; SD, 14.5 years; range, 21-94 years), and the median lesion diameter was 12 mm (mean, 14 mm; SD, 7.9 mm; range, 1-53 mm). The median Emax of the 1562 masses (32.1% malignant) was 71 kPa (mean, 90 kPa; SD, 65 kPa; IQR, 31-170 kPa). Of 502 malignancies, 23 (4.6%) ductal carcinoma in situ (DCIS) masses had a median Emax of 126 kPa (IQR, 71-180 kPa) and were less stiff than 468 invasive carcinomas (median Emax, 180 kPa [IQR, 138-180 kPa]; p = 0.002). Benign lesions were much softer than malignancies (median Emax, 43 kPa [IQR, 24-83 kPa] vs 180 kPa [IQR, 129-180 kPa]; p masses. Despite overlap in Emax values, maximum stiffness measured by SWE is a highly effective predictor of the histopathologic severity of sonographically depicted breast masses.

  12. Mutation analysis of breast cancer gene BRCA among breast cancer Jordanian females

    International Nuclear Information System (INIS)

    Atoum, Manar F.; Al-Kayed, Sameer A.

    2004-01-01

    To screen mutations of the tumor suppressor breast cancer susceptibility gene 1 (BRCA1) within 3 exons among Jordanian breast cancer females. A total of 135 Jordanian breast cancer females were genetically analyzed by denaturing gradient electrophoresis (DGGE) for mutation detection in 3 BRCA1 exons (2, 11 and 20) between 2000-2002 in Al-Basheer Hospital, Amman, Jordan. Of the studied patients 50 had a family history of breast cancer, 28 had a family history of cancer other than breast cancer, and 57 had no family history of any cancer. Five germline mutations were detected among breast cancer females with a family history of breast cancers (one in exon 2 and 4 mutations in exon 11). Another germline mutation (within exon 11) was detected among breast cancer females with family history of cancer other than breast cancer, and no mutation was detected among breast cancer females with no family history of any cancer or among normal control females. Screening mutations within exon 2, exon 11 and exon 20 showed that most screened mutations were within BRCA1 exon 11 among breast cancer Jordanian families with a family history of breast cancer. (author)

  13. Catalytic growth of carbon nanotubes with large inner diameters

    Directory of Open Access Journals (Sweden)

    WEI REN ZHONG

    2005-02-01

    Full Text Available Carbon nanotubes (2.4 g/g catalyst, with large inner diameters were successfully synthesized through pyrolysis of methane on a Ni–Cu–Al catalyst by adding sodium carbonate into the carbon nanotubes growth system. The inner diameter of the carbon nanotubes prepared by this method is about 20–60 nm, while their outer diameter is about 40–80 nm. Transmission electron microscopy and X-ray diffraction were employed to investigate the morphology and microstructures of the carbon nanotubes. The analyses showed that these carbon nanotubes have large inner diameters and good graphitization. The addition of sodium carbonate into the reaction system brings about a slight decrease in the methane conversion and the yield of carbon. The experimental results showed that sodium carbonate is a mildly toxic material which influenced the catalytic activity of the Ni–Cu–Al catalyst and resulted in the formation of carbon nanotubes with large inner diameters. The growth mechanism of the carbon nanotubes with large inner diameters is discussed in this paper.

  14. Radiotracer technique for leakage detection under simulated conditions

    International Nuclear Information System (INIS)

    Yelgaonkar, V.N.; Sharma, V.K.; Tapase, A.S.

    2001-01-01

    Radiotracer techniques are often used to locate leaks in underground pipelines. An attempt was made to standardize radiotracer pulse migration in terms of minimum detectable limit. For this purpose a 6 inch diameter 1200 long steel pipe was used. Two leak rates viz. 10 litres per minute and 1 litre per minute with an accuracy of ± 10% were simulated. The experiments on this pipeline showed that this method could be used to locate a leak of the order of 1 litre per minute in a 6 inch diameter isolated underground pipeline. (author)

  15. Metallurgical analysis of high pressure gas pipelines rupture

    International Nuclear Information System (INIS)

    Hasan, F.; Ahmed, F.

    2007-01-01

    On 6 July 2004, two parallel-running gas pipelines (18-inch and 24-inch diameters), in the main transmission network of SNGPL (a gas company in Pakistan) were ruptured. The ruptures occurred in the early hours of the morning about 8 miles downstream of the compressor station AC-4. The ruptures were indicated by the increased gas flow at the outlet of AC-4 (1), first at about 0648 hours and then again about 20 minutes later. The gas escaping from the ruptured lines had caught fire, and the flames had also 'affected' a third parallel-running pipeline of 30-inch diameter, lying next to the 24-inch line. The metallurgical examination of the two ruptured lines showed that the 24-inch line was ruptured with the help of an explosive device that had been placed on the underside of the pipe. An examination of the 18-inch line showed that this pipe had failed as a result of the heating of the pipe-wall, presumably, by the flame emanating from the 24-inch line. These two observations clearly suggested that the 24-inch line was the first to rupture (by explosives), and the fire following this rupture had heated the 18-inch pipe to a temperature where its yield strength was unable to support the inside gas pressure. The 20 minutes time interval between the two ruptures was obviously the time taken by the 18 inch pipe to be heated upto the level where it started to yield. The 30-inch line lying next to the 24-inch line was affected to the extent that its coating had been burnt-off over a length of about 40-50 feet. However, the pipe did not exhibit any signs of deshaping or deformation what-so-ever. A replica metallographic examination indicated that the microstructure of the pipe was not measurably affected by the heat. It was thus decided not to replace the affected part of the 30-inch pipe, but only to re-coat this affected portion. (author)

  16. The relationships between breast volume, breast dense volume and volumetric breast density with body mass index, body fat mass and ethnicity

    Science.gov (United States)

    Zakariyah, N.; Pathy, N. B.; Taib, N. A. M.; Rahmat, K.; Judy, C. W.; Fadzil, F.; Lau, S.; Ng, K. H.

    2016-03-01

    It has been shown that breast density and obesity are related to breast cancer risk. The aim of this study is to investigate the relationships of breast volume, breast dense volume and volumetric breast density (VBD) with body mass index (BMI) and body fat mass (BFM) for the three ethnic groups (Chinese, Malay and Indian) in Malaysia. We collected raw digital mammograms from 2450 women acquired on three digital mammography systems. The mammograms were analysed using Volpara software to obtain breast volume, breast dense volume and VBD. Body weight, BMI and BFM of the women were measured using a body composition analyser. Multivariable logistic regression was used to determine the independent predictors of increased overall breast volume, breast dense volume and VBD. Indians have highest breast volume and breast dense volume followed by Malays and Chinese. While Chinese are highest in VBD, followed by Malay and Indian. Multivariable analysis showed that increasing BMI and BFM were independent predictors of increased overall breast volume and dense volume. Moreover, BMI and BFM were independently and inversely related to VBD.

  17. Breast cancer

    International Nuclear Information System (INIS)

    Tokunaga, Masayoshi

    1992-01-01

    More than 20-year follow-up of A-bomb survivors in Hiroshima and Nagasaki has a crucial role in determining the relationship of radiation to the occurrence of breast cancer. In 1967, Wanebo et al have first reported 27 cases of breast cancer during the period 1950-1966 among the Adult Health Study population of A-bomb survivors. Since then, follow-up surveys for breast cancer have been made using the Life Span Study (LSS) cohort, and the incidence of breast cancer has increased year by year; that is breast cancer was identified in 231 cases by the first LSS series (1950-1969), 360 cases by the second LSS series (1950-1974), 564 cases by the third LSS series (1950-1980), and 816 cases in the fourth LSS series (1950-1085). The third LSS series have revealed a high risk for radiation-induced breast cancer in women aged 10 or less at the time of exposure (ATE). Both relative and absolute risks are found to be decreased with increasing ages ATE. Based on the above-mentioned findings and other studies on persons exposed medical radiation, radiation-induced breast cancer is characterized by the following: (1) the incidence of breast cancer is linearly increased with increasing radiation doses; (2) both relative and absolute risks for breast cancer are high in younger persons ATE; (3) age distribution of breast cancer in proximally exposed A-bomb survivors is the same as that in both distally A-bomb survivors and non-exposed persons, and there is no difference in histology between the former and latter groups. Thus, immature mammary gland cells before the age of puberty are found to be most radiosensitive. (N.K.)

  18. Breast tissue, oral and urinary microbiomes in breast cancer

    OpenAIRE

    Wang, Hannah; Altemus, Jessica; Niazi, Farshad; Green, Holly; Calhoun, Benjamin C.; Sturgis, Charles; Grobmyer, Stephen R.; Eng, Charis

    2017-01-01

    It has long been proposed that the gut microbiome contributes to breast carcinogenesis by modifying systemic estrogen levels. This is often cited as a possible mechanism linking breast cancer and high-fat, low-fiber diets as well as antibiotic exposure, associations previously identified in population-based studies. More recently, a distinct microbiome has been identified within breast milk and tissue, but few studies have characterized differences in the breast tissue microbiota of patients ...

  19. 7 CFR 51.3152 - Standard pack.

    Science.gov (United States)

    2010-01-01

    ... outside a diameter range of one-fourth inch; when the average diameter of nectarines in any container is.... (g) “Diameter” means the greatest dimension measured at right angles to a line from stem to blossom...

  20. On the diameter of dot-critical graphs

    Directory of Open Access Journals (Sweden)

    Doost Ali Mojdeh

    2009-01-01

    Full Text Available A graph G is \\(k\\-dot-critical (totaly \\(k\\-dot-critical if \\(G\\ is dot-critical (totaly dot-critical and the domination number is \\(k\\. In the paper [T. Burtona, D. P. Sumner, Domination dot-critical graphs, Discrete Math, 306 (2006, 11-18] the following question is posed: What are the best bounds for the diameter of a \\(k\\-dot-critical graph and a totally \\(k\\-dot-critical graph \\(G\\ with no critical vertices for \\(k \\geq 4\\? We find the best bound for the diameter of a \\(k\\-dot-critical graph, where \\(k \\in\\{4,5,6\\}\\ and we give a family of \\(k\\-dot-critical graphs (with no critical vertices with sharp diameter \\(2k-3\\ for even \\(k \\geq 4\\.

  1. Nanomanipulation of 2 inch wafer fabrication of vertically aligned carbon nanotube arrays by nanoimprint lithography

    DEFF Research Database (Denmark)

    Bu, Ian Y. Y.; Eichhorn, Volkmar; Carlson, Kenneth

    2011-01-01

    Carbon nanotube (CNT) arrays are typically defined by electron beam lithography (EBL), and hence limited to small areas due to the low throughput. To obtain wafer‐scale fabrication we propose large area thermal nanoimprint lithography (NIL). A 2‐inch stamp master is defined using EBL for subsequent......, efficient production of wafer‐scale/larger arrays of CNTs has been achieved. The CNTs have been deposited by wafer‐scale plasma enhanced chemical vapour deposition (PECVD) of C2H2/NH3. Substrates containing such nanotubes have been used to automate nanorobotic manipulation sequences of individual CNTs...

  2. Dynamic contrast-enhanced MRI and sonography in patients receiving primary chemotherapy for breast cancer

    International Nuclear Information System (INIS)

    Montemurro, Filippo; Aglietta, Massimo; Martincich, Laura; Rosa, Giovanni De; Cirillo, Stefano; Marra, Vincenzo; Regge, Daniele; Biglia, Nicoletta; Sismondi, Piero; Gatti, Marco

    2005-01-01

    We compared dynamic contrast-enhanced MRI (DCE-MRI) and sonography (US) for monitoring tumour size in 21 patients with breast cancer undergoing primary chemotherapy (PCT) followed by surgery. The correlation between DCE-MRI and US measurements of tumour size, defined as the product of the two major diameters, was 0.555 (P=0.009), 0.782 (P 2 , P 2 , P=0.009). After PCT, the median tumour size measured by the two techniques was similar (256 vs 289 mm 2 for DCE-MRI and US, respectively, P=0.859). The correlation with the histopathological major tumour diameter was 0.824 (P<0.001) and 0.705 (P<0.001) for post-treatment DCE-MRI and US, respectively. Measurements of the final major tumour diameter by DCE-MRI tended to be more precise, including cases achieving a pathological complete response. Randomized trials are warranted to establish the clinical impact of the initial discrepancy in tumour size estimates between DCE-MRI and US, and the trend towards a better definition of the final tumour size provided by DCE-MRI in this clinical setting. (orig.)

  3. Breast Cancer

    Science.gov (United States)

    Breast cancer affects one in eight women during their lives. No one knows why some women get breast cancer, but there are many risk factors. Risks that ... who have family members with breast or ovarian cancer may wish to be tested for the genes. ...

  4. On the performance of small diameter gas cyclones

    International Nuclear Information System (INIS)

    Halasz, Marcos Roberto Teixeira

    2002-02-01

    Small diameter cyclones represent a potential alternative for the removal of small diameter particles from gaseous mixtures as well as the environmental control of their emission. In order to establish feasible configurations of a small diameter cyclone applied in the separation of solid particles dispersed in a gas and considering a large quantify of experimental data in literature, neural networks were used to estimate the equipment grade efficiency and pressure drop. In order to evaluate a performance of many small diameters configurations and analysis was carried of parametrical sensibility which determines the most important variables on separation efficiency determination. A set of experimental runs was carried out in a lab-scale mini-cyclone in order to obtain the separation efficiency and pressure drop for different configurations, and evaluate the feasibility of coupling a post-cyclone device to improve the equipment overall performance. The cyclones used presented diameters of 0.03 and 0.05 m and the remaining dimensions varied proportionally about those found in Stairmand high-efficiency cyclones. Experimental separation efficiencies up to 99% were obtained in this work. These results confirm the feasibility of the experimental set-up configuration proposed. (author)

  5. Breast Cancer Overview

    Science.gov (United States)

    ... are here Home > Types of Cancer > Breast Cancer Breast Cancer This is Cancer.Net’s Guide to Breast Cancer. Use the menu below to choose the Overview/ ... social workers, and patient advocates. Cancer.Net Guide Breast Cancer Introduction Statistics Medical Illustrations Risk Factors and Prevention ...

  6. Prone breast radiotherapy in early-stage breast cancer: a preliminary analysis

    International Nuclear Information System (INIS)

    Grann, Alison; McCormick, Beryl; Chabner, Elizabeth S.; Gollamudi, Smitha V.; Schupak, Karen D.; Mychalczak, Borys R.; Heerdt, Alexandra S.; Merchant, Thomas E.; Hunt, Margie A.

    2000-01-01

    Purpose: Women with large breasts have marked dose inhomogeneity and often an inferior cosmetic outcome when treated with breast conservation compared to smaller-sized patients. We designed a prone breast board, which both minimizes breast separation and irradiated lung or heart volume. We report feasibility, cosmesis, and preliminary local control and survival for selected women with Stage 0-II breast cancer. Materials and Methods: Fifty-six patients with clinical Stage 0-II breast cancer were treated with lumpectomy and breast irradiation utilizing a prototype prone breast board. A total of 59 breasts were treated. Indications for treatment in the prone position were large or pendulous breast size (n = 57), or a history of cardiopulmonary disease (n = 2). The median bra size was 41D (range, 34D-44EE). Cosmesis was evaluated on a 1-10 (worst-to-best) scale. Results: Acute toxicity included skin erythema (80% of patients experienced Grade I or Grade II erythema), breast edema (72% of patients experienced mild edema), pruritus (20% of patients), and fatigue (20% of patients reported mild fatigue). One patient required a treatment break. The only late toxicity was related to long-term cosmesis. The mean overall cosmesis score for 53 patients was 9.37 (range, 8-10). Actuarial 3- and 5-year local control rates are 98%. Actuarial overall survival at 3 and 5 years are 98% and 94%. Conclusion: Our data indicate that treating selected women with prone breast radiotherapy is feasible and tolerated. The approach results in excellent cosmesis, and short-term outcome is comparable to traditional treatment techniques. This technique offers an innovative alternative to women who might not otherwise be considered candidates for breast conservation

  7. A dedicated breast-PET/CT scanner: Evaluation of basic performance characteristics.

    Science.gov (United States)

    Raylman, Raymond R; Van Kampen, Will; Stolin, Alexander V; Gong, Wenbo; Jaliparthi, Gangadhar; Martone, Peter F; Smith, Mark F; Sarment, David; Clinthorne, Neal H; Perna, Mark

    2018-04-01

    Application of advanced imaging techniques, such as PET and x ray CT, can potentially improve detection of breast cancer. Unfortunately, both modalities have challenges in the detection of some lesions. The combination of the two techniques, however, could potentially lead to an overall improvement in diagnostic breast imaging. The purpose of this investigation is to test the basic performance of a new dedicated breast-PET/CT. The PET component consists of a rotating pair of detectors. Its performance was evaluated using the NEMA NU4-2008 protocols. The CT component utilizes a pulsed x ray source and flat panel detector mounted on the same gantry as the PET scanner. Its performance was assessed using specialized phantoms. The radiation dose to a breast during CT imaging was explored by the measurement of free-in-air kerma and air kerma measured at the center of a 16 cm-diameter PMMA cylinder. Finally, the combined capabilities of the system were demonstrated by imaging of a micro-hot-rod phantom. Overall, performance of the PET component is comparable to many pre-clinical and other dedicated breast-PET scanners. Its spatial resolution is 2.2 mm, 5 mm from the center of the scanner using images created with the single-sliced-filtered-backprojection algorithm. Peak NECR is 24.6 kcps; peak sensitivity is 1.36%; the scatter fraction is 27%. Spatial resolution of the CT scanner is 1.1 lp/mm at 10% MTF. The free-in-air kerma is 2.33 mGy, while the PMMA-air kerma is 1.24 mGy. Finally, combined imaging of a micro-hot-rod phantom illustrated the potential utility of the dual-modality images produced by the system. The basic performance characteristics of a new dedicated breast-PET/CT scanner are good, demonstrating that its performance is similar to current dedicated PET and CT scanners. The potential value of this system is the capability to produce combined duality-modality images that could improve detection of breast disease. The next stage in development of this system

  8. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    International Nuclear Information System (INIS)

    Kang, Yun Dan; Kim, You Me

    2016-01-01

    The purpose of this study was to compare needle aspiration and vacuum-assisted biopsy in the ultrasound-guided treatment of lactational breast abscesses. Between January 2005 and December 2014, a total of 74 patients presented with lactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated with needle aspiration (n=25) or vacuum-assisted biopsy (n=19). Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student's t test and the chi-square test were used to compare the variables. No significant difference was found in the cure rate between the needle aspiration group (22/25, 88%) and the vacuum-assisted biopsy group (18/19, 94.7%) (P=0.441). However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days) than in the needle aspiration group (9.0 days) (P=0.001). Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses

  9. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    Directory of Open Access Journals (Sweden)

    Yun-Dan Kang

    2016-04-01

    Full Text Available Purpose: The purpose of this study was to compare needle aspiration and vacuum-assistedbiopsy in the ultrasound-guided treatment of lactational breast abscesses. Methods: Between January 2005 and December 2014, a total of 74 patients presented withlactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated withneedle aspiration (n=25 or vacuum-assisted biopsy (n=19. Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student’s t test and the chi-square test were used to compare the variables. Results: No significant difference was found in the cure rate between the needle aspirationgroup (22/25, 88% and the vacuum-assisted biopsy group (18/19, 94.7% (P=0.441. However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days than in the needle aspiration group (9.0 days (P=0.001. Conclusion: Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses.

  10. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yun Dan; Kim, You Me [Dankook University College of Medicine, Cheonan (Korea, Republic of)

    2016-03-15

    The purpose of this study was to compare needle aspiration and vacuum-assisted biopsy in the ultrasound-guided treatment of lactational breast abscesses. Between January 2005 and December 2014, a total of 74 patients presented with lactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated with needle aspiration (n=25) or vacuum-assisted biopsy (n=19). Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student's t test and the chi-square test were used to compare the variables. No significant difference was found in the cure rate between the needle aspiration group (22/25, 88%) and the vacuum-assisted biopsy group (18/19, 94.7%) (P=0.441). However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days) than in the needle aspiration group (9.0 days) (P=0.001). Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses.

  11. Best estimate small break LOCA analysis for KNGR SIS optimization

    International Nuclear Information System (INIS)

    Song, JIn Ho; Lim, Hong Sik; Bae, Kyoo Hwan; Lee, Joon

    1996-01-01

    The KNGR has an advanced ECCS design feature which employs four mechanically-separated SI trains where each train consisting of one HPSI pump and one SIT injects ECC water directly into the reactor vessel downcomer annulus. To demonstrate that the KNGR ECCS design features meet the EPRI ALWR requirements of no core uncovery for a break of up to 6 inch diameter, small break LOCA cases with various break sizes were analyzed using a best-estimate analytical procedure. Two kinds of break locations are considered: cold leg and DVI line breaks. It was observed that the KNGR ECCS design can tolerate a cold leg break of up to 10 inches with no core uncovery. However, since DVI line break with 6 inch diameter undergoes slight core uncovery, further investigation is required for KNGR SIS optimization

  12. Characterization of Breast Lesions: Comparison of Digital Breast Tomosynthesis and Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Sun Ah; Chang, Jung Min; Cho, Nariya; Yi, Ann; Moon, Woo Kyung

    2015-01-01

    To compare the diagnostic performance of digital breast tomosynthesis (DBT) and conventional breast ultrasound (US) to characterize breast lesions as benign or malignant. A total of 332 women, presenting for screening examinations or for breast biopsy between March and June 2012 were recruited to undergo digital mammography (DM), DBT, and breast US examination. Among them, 113 patients with 119 breast lesions depicted on DM were finally included. Three blinded radiologists performed an enriched reader study and reviewed the DBT and US images. Each reader analyzed the lesions in random order, assigned Breast Imaging Reporting and Data System (BI-RADS) descriptors, rated the images for the likelihood of malignancy (%) and made a BI-RADS final assessment. Diagnostic accuracy, as assessed by the area under the receiver operating characteristic curve, sensitivity, and specificity of DBT and US were compared. Among the 119 breast lesions depicted on DM, 75 were malignant and the remaining 44 were benign. The average diagnostic performance for characterizing breast lesions as benign or malignant in terms of area under the curve was 0.899 for DBT and 0.914 for US (p = 0.394). Mean sensitivity (97.3% vs. 98.7%, p = 0.508) and specificity (44.7% vs. 39.4%, p = 0.360) were also not significantly different. Digital breast tomosynthesis may provide similar reader lesion characterization performance to that of US for breast lesions depicted on DM

  13. Characterization of Breast Lesions: Comparison of Digital Breast Tomosynthesis and Ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Ah [Department of Radiology, Human Medical Imaging & Intervention Center, Seoul 135-120 (Korea, Republic of); Chang, Jung Min; Cho, Nariya [Department of Radiology, Seoul National University Hospital, Seoul 110-744 (Korea, Republic of); Yi, Ann [Department of Radiology, Seoul National University Hospital Healthcare System Gangnam Center, Seoul 135-984 (Korea, Republic of); Moon, Woo Kyung [Department of Radiology, Seoul National University Hospital, Seoul 110-744 (Korea, Republic of)

    2015-11-01

    To compare the diagnostic performance of digital breast tomosynthesis (DBT) and conventional breast ultrasound (US) to characterize breast lesions as benign or malignant. A total of 332 women, presenting for screening examinations or for breast biopsy between March and June 2012 were recruited to undergo digital mammography (DM), DBT, and breast US examination. Among them, 113 patients with 119 breast lesions depicted on DM were finally included. Three blinded radiologists performed an enriched reader study and reviewed the DBT and US images. Each reader analyzed the lesions in random order, assigned Breast Imaging Reporting and Data System (BI-RADS) descriptors, rated the images for the likelihood of malignancy (%) and made a BI-RADS final assessment. Diagnostic accuracy, as assessed by the area under the receiver operating characteristic curve, sensitivity, and specificity of DBT and US were compared. Among the 119 breast lesions depicted on DM, 75 were malignant and the remaining 44 were benign. The average diagnostic performance for characterizing breast lesions as benign or malignant in terms of area under the curve was 0.899 for DBT and 0.914 for US (p = 0.394). Mean sensitivity (97.3% vs. 98.7%, p = 0.508) and specificity (44.7% vs. 39.4%, p = 0.360) were also not significantly different. Digital breast tomosynthesis may provide similar reader lesion characterization performance to that of US for breast lesions depicted on DM.

  14. Hypofractionated Whole-Breast Radiation Therapy: Does Breast Size Matter?

    Energy Technology Data Exchange (ETDEWEB)

    Hannan, Raquibul, E-mail: Raquibul.Hannan@gmail.com [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Thompson, Reid F.; Chen Yu; Bernstein, Karen; Kabarriti, Rafi; Skinner, William [Department of Radiation Oncology, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York (United States); Chen, Chin C. [Department of Radiation Oncology, Columbia University Medical Center, New York, New York (United States); Landau, Evan; Miller, Ekeni; Spierer, Marnee; Hong, Linda; Kalnicki, Shalom [Department of Radiation Oncology, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York (United States)

    2012-11-15

    Purpose: To evaluate the effects of breast size on dose-volume histogram parameters and clinical toxicity in whole-breast hypofractionated radiation therapy using intensity modulated radiation therapy (IMRT). Materials and Methods: In this retrospective study, all patients undergoing breast-conserving therapy between 2005 and 2009 were screened, and qualifying consecutive patients were included in 1 of 2 cohorts: large-breasted patients (chest wall separation >25 cm or planning target volume [PTV] >1500 cm{sub 3}) (n=97) and small-breasted patients (chest wall separation <25 cm and PTV <1500 cm{sub 3}) (n=32). All patients were treated prone or supine with hypofractionated IMRT to the whole breast (42.4 Gy in 16 fractions) followed by a boost dose (9.6 Gy in 4 fractions). Dosimetric and clinical toxicity data were collected and analyzed using the R statistical package (version 2.12). Results: The mean PTV V95 (percentage of volume receiving >= 95% of prescribed dose) was 90.18% and the mean V105 percentage of volume receiving >= 105% of prescribed dose was 3.55% with no dose greater than 107%. PTV dose was independent of breast size, whereas heart dose and maximum point dose to skin correlated with increasing breast size. Lung dose was markedly decreased in prone compared with supine treatments. Radiation Therapy Oncology Group grade 0, 1, and 2 skin toxicities were noted acutely in 6%, 69%, and 25% of patients, respectively, and at later follow-up (>3 months) in 43%, 57%, and 0% of patients, respectively. Large breast size contributed to increased acute grade 2 toxicity (28% vs 12%, P=.008). Conclusions: Adequate PTV coverage with acceptable hot spots and excellent sparing of organs at risk was achieved by use of IMRT regardless of treatment position and breast size. Although increasing breast size leads to increased heart dose and maximum skin dose, heart dose remained within our institutional constraints and the incidence of overall skin toxicity was comparable

  15. Ultrasound screening of contralateral breast after surgery for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ja [Department of Radiology, Seoul Metropolitan Government Seoul National University, Boramae Medical Center (Korea, Republic of); Chung, Se-Yeong; Chang, Jung Min; Cho, Nariya [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Han, Wonshik [Department of Surgery, Seoul National University Hospital (Korea, Republic of); Moon, Woo Kyung, E-mail: moonwk@snu.ac.kr [Department of Radiology, Seoul National University Hospital (Korea, Republic of)

    2015-01-15

    Highlights: • The addition of supplemental US to mammography depicted additional 5.0 cancers per 1000 postoperative women. • Positive biopsy rate of mammography-detected lesions was 66.7% (4 of 6) and that of US-detected lesions was 40.0% (6 of 15). • US can be helpful to detect mammographically occult breast cancer in the contralateral breast in women with previous history of cancer and dense breast. - Abstract: Objective: To determine whether supplemental screening ultrasound (US) to mammography could improve cancer detection rate of the contralateral breast in patients with a personal history of breast cancer and dense breasts. Materials and methods: During a one-year study period, 1314 screening patients with a personal history of breast cancer and dense breasts simultaneously underwent mammography and breast US. BI-RADS categories were given for mammography or US-detected lesions in the contralateral breast. The reference standard was histology and/or 1-year imaging follow-up, and the cancer rate according to BI-RADS categories and cancer detection rate and positive biopsy rate according to detection modality were analyzed. Results: Of 1314 patients, 84 patients (6.4%) were categorized as category 3 with one interval cancer and one cancer which was upgraded to category 4A after 6-month follow-up US (2.5% cancer rate, 95% CIs 1.5–9.1%). Fifteen patients (1.1%) had category 4A or 4B lesions in the contralateral breast. Four lesions were detected on mammography (two lesions were also visible on US) and 11 lesions were detected on US and 5 cancers were confirmed (33.3%, 95% CIs 15.0–58.5%). Six patients (0.5%) had category 4C lesions, 2 detected on mammography and 4 on US and 4 cancers were confirmed (66.7%, 95% CIs 29.6–90.8%). No lesions were categorized as category 5 in the contralateral breast. Cancer detection rate by mammography was 3.3 per 1000 patients and that by US was 5.0 per 1000 patients, therefore overall cancer detection rate by

  16. Ultrasound screening of contralateral breast after surgery for breast cancer

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Chung, Se-Yeong; Chang, Jung Min; Cho, Nariya; Han, Wonshik; Moon, Woo Kyung

    2015-01-01

    Highlights: • The addition of supplemental US to mammography depicted additional 5.0 cancers per 1000 postoperative women. • Positive biopsy rate of mammography-detected lesions was 66.7% (4 of 6) and that of US-detected lesions was 40.0% (6 of 15). • US can be helpful to detect mammographically occult breast cancer in the contralateral breast in women with previous history of cancer and dense breast. - Abstract: Objective: To determine whether supplemental screening ultrasound (US) to mammography could improve cancer detection rate of the contralateral breast in patients with a personal history of breast cancer and dense breasts. Materials and methods: During a one-year study period, 1314 screening patients with a personal history of breast cancer and dense breasts simultaneously underwent mammography and breast US. BI-RADS categories were given for mammography or US-detected lesions in the contralateral breast. The reference standard was histology and/or 1-year imaging follow-up, and the cancer rate according to BI-RADS categories and cancer detection rate and positive biopsy rate according to detection modality were analyzed. Results: Of 1314 patients, 84 patients (6.4%) were categorized as category 3 with one interval cancer and one cancer which was upgraded to category 4A after 6-month follow-up US (2.5% cancer rate, 95% CIs 1.5–9.1%). Fifteen patients (1.1%) had category 4A or 4B lesions in the contralateral breast. Four lesions were detected on mammography (two lesions were also visible on US) and 11 lesions were detected on US and 5 cancers were confirmed (33.3%, 95% CIs 15.0–58.5%). Six patients (0.5%) had category 4C lesions, 2 detected on mammography and 4 on US and 4 cancers were confirmed (66.7%, 95% CIs 29.6–90.8%). No lesions were categorized as category 5 in the contralateral breast. Cancer detection rate by mammography was 3.3 per 1000 patients and that by US was 5.0 per 1000 patients, therefore overall cancer detection rate by

  17. Comparison of fluorine-18 fluorodeoxyglucose positron emission tomography and technetium-99m methoxyisobutylisonitrile scintimammography in the detection of breast tumours

    Energy Technology Data Exchange (ETDEWEB)

    Palmedo, H.; Bender, H.; Gruenwald, F.; Zamora, P.; Biersack, H.J. [Department of Nuclear Medicine, University of Bonn (Germany); Mallmann, P.; Krebs, D. [Department of Gynecology and Obstetrics, University of Bonn (Germany)

    1997-09-01

    The aim of this study was to compare, in breast cancer patients, the diagnostic accuracy of positron emission tomography (PET) using fluorine-18 fluorodeoxyglucose (FDG) and scintimammography (SMM) using technetium-99m methoxyisobutylisonitrile (MIBI). A total of 20 patients (40 breasts with 22 lesions) were evaluated serially with MIBI and, on the following day, with FDG. For SMM, planar and single-photon emission tomography imaging in the prone position was performed starting at 10 min following the injection of MIBI (740 MBq). For PET, scans were acquired 45-60 min after the injection of FDG (370 MBq) and attentuation correction was performed following transmission scans. Results from SMM and PET were subsequently compared with the histopathology results. True-positive results were obtained in 12/13 primary breast cancers (mean diameter=29 mm, range 8-53 mm) with both FDG and MIBI. False-negative results were obtained in two local recurrences (diameter <9 mm) with both FDG and MIBI. In benign disease, FDG and MIBI did not localize three fibrocystic lesions, two fibroadenomas and one inflammatory lesion (true-negative), but both localized one fibroadenoma (false-positive). Collectively, the results demonstrate a sensitivity of 92%, and a specificity of 86%, for primary breast cancer regardless of whether FDG or MIBI was used. In contrast to MIBI scintigraphy, FDG PET scored the axillae correctly as either positive (metastatic disease) or negative (no axillary disease) in all 12 patients. The tumour/non-tumour ratio for MIBI was 1.97 (range 1.43-3.1). The mean standard uptake value (SUV) for FDG uptake was 2.57 (range 0.3-6.2). The diagnostic accuracy of SMM was equivalent to that of FDG PET for the detection of primary breast cancer. For the detection of in situ lymph node metastases of the axilla, FDG seems to be more sensitive than {sup 99m}Tc-MIBI. (orig.). With 4 figs., 2 tabs.

  18. Diameter dependent electron transfer kinetics in semiconductor-enzyme complexes.

    Science.gov (United States)

    Brown, Katherine A; Song, Qing; Mulder, David W; King, Paul W

    2014-10-28

    Excited state electron transfer (ET) is a fundamental step for the catalytic conversion of solar energy into chemical energy. To understand the properties controlling ET between photoexcited nanoparticles and catalysts, the ET kinetics were measured for solution-phase complexes of CdTe quantum dots and Clostridium acetobutylicum [FeFe]-hydrogenase I (CaI) using time-resolved photoluminescence spectroscopy. Over a 2.0-3.5 nm diameter range of CdTe nanoparticles, the observed ET rate (kET) was sensitive to CaI concentration. To account for diameter effects on CaI binding, a Langmuir isotherm and two geometric binding models were created to estimate maximal CaI affinities and coverages at saturating concentrations. Normalizing the ET kinetics to CaI surface coverage for each CdTe diameter led to k(ET) values that were insensitive to diameter, despite a decrease in the free energy for photoexcited ET (ΔGET) with increasing diameter. The turnover frequency (TOF) of CaI in CdTe-CaI complexes was measured at several molar ratios. Normalization for diameter-dependent changes in CaI coverage showed an increase in TOF with diameter. These results suggest that k(ET) and H2 production for CdTe-CaI complexes are not strictly controlled by ΔG(ET) and that other factors must be considered.

  19. Impact of contra-lateral breast reshaping on mammographic surveillance in women undergoing breast reconstruction following mastectomy for breast cancer.

    Science.gov (United States)

    Nava, Maurizio B; Rocco, Nicola; Catanuto, Giuseppe; Falco, Giuseppe; Capalbo, Emanuela; Marano, Luigi; Bordoni, Daniele; Spano, Andrea; Scaperrotta, Gianfranco

    2015-08-01

    The ultimate goal of breast reconstruction is to achieve symmetry with the contra-lateral breast. Contra-lateral procedures with wide parenchymal rearrangements are suspected to impair mammographic surveillance. This study aims to evaluate the impact on mammographic detection of mastopexies and breast reductions for contralateral adjustment in breast reconstruction. We retrospectively evaluated 105 women affected by uni-lateral breast cancer who underwent mastectomy and immediate two-stage reconstruction between 2002 and 2007. We considered three groups according to the contra-lateral reshaping technique: mastopexy or breast reduction with inferior dermoglandular flap (group 1); mastopexy or breast reduction without inferior dermoglandular flap (group 2); no contra-lateral reshaping (group 3). We assessed qualitative mammographic variations and breast density in the three groups. Statistically significant differences have been found when comparing reshaped groups with non reshaped groups regarding parenchymal distortions, skin thickening and stromal edema, but these differences did not affect cancer surveillance. The surveillance mammography diagnostic accuracy in contra-lateral cancer detection was not significantly different between the three groups (p = 0.56), such as the need for MRI for equivocal findings at mammographic contra-lateral breast (p = 0.77) and the need for core-biopsies to confirm mammographic suspect of contra-lateral breast cancer (p = 0.90). This study confirms previous reports regarding the safety of mastopexies and breast reductions when performed in the setting of contra-lateral breast reshaping after breast reconstruction. Mammographic accuracy, sensitivity and specificity are not affected by the glandular re-arrangement. These results provide a further validation of the safety of current reconstructive paradigms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Breast Cancer -- Male

    Science.gov (United States)

    ... Home > Types of Cancer > Breast Cancer in Men Breast Cancer in Men This is Cancer.Net’s Guide to Breast Cancer in Men. Use the menu below to choose ... social workers, and patient advocates. Cancer.Net Guide Breast Cancer in Men Introduction Statistics Risk Factors and Prevention ...

  1. Adherence to Guidelines for Breast Surveillance in Breast Cancer Survivors.

    Science.gov (United States)

    Ruddy, Kathryn J; Sangaralingham, Lindsey; Freedman, Rachel A; Mougalian, Sarah; Neuman, Heather; Greenberg, Caprice; Jemal, Ahmedin; Duma, Narjust; Haddad, Tufia C; Lemaine, Valerie; Ghosh, Karthik; Hieken, Tina J; Hunt, Katie; Vachon, Celine; Gross, Cary; Shah, Nilay D

    2018-05-01

    Background: Guidelines recommend annual mammography after curative-intent treatment for breast cancer. The goal of this study was to assess contemporary patterns of breast imaging after breast cancer treatment. Methods: Administrative claims data were used to identify privately insured and Medicare Advantage beneficiaries with nonmetastatic breast cancer who had residual breast tissue (not bilateral mastectomy) after breast surgery between January 2005 and May 2015. We calculated the proportion of patients who had a mammogram, MRI, both, or neither during each of 5 subsequent 13-month periods. Multinomial logistic regression was used to assess associations between patient characteristics, healthcare use, and breast imaging in the first and fifth years after surgery. Results: A total of 27,212 patients were followed for a median of 2.9 years (interquartile range, 1.8-4.6) after definitive breast cancer surgery. In year 1, 78% were screened using mammography alone, 1% using MRI alone, and 8% using both tests; 13% did not undergo either. By year 5, the proportion of the remaining cohort (n=4,790) who had no breast imaging was 19%. Older age was associated with an increased likelihood of mammography and a decreased likelihood of MRI during the first and fifth years. Black race, mastectomy, chemotherapy, and no MRI at baseline were all associated with a decreased likelihood of both types of imaging. Conclusions: Even in an insured cohort, a substantial proportion of breast cancer survivors do not undergo annual surveillance breast imaging, particularly as time passes. Understanding factors associated with imaging in cancer survivors may help improve adherence to survivorship care guidelines. Copyright © 2018 by the National Comprehensive Cancer Network.

  2. Modelling of tomato stem diameter growth rate based on physiological responses

    International Nuclear Information System (INIS)

    Li, L.; Tan, J.; Lv, T.

    2017-01-01

    The stem diameter is an important parameter describing the growth of tomato plant during vegetative growth stage. A stem diameter growth model was developed to predict the response of plant growth under different conditions. By analyzing the diurnal variations of stem diameter in tomato (Solanum lycopersicum L.), it was found that the stem diameter measured at 3:00 am was the representative value as the daily basis of tomato stem diameter. Based on the responses of growth rate in stem diameter to light and temperature, a linear regression relationship was applied to establish the stem diameter growth rate prediction model for the vegetative growth stage in tomato and which was further validated by experiment. The root mean square error (RMSE) and relative error (RE) were used to test the correlation between measured and modeled stem diameter variations. Results showed that the model can be used in prediction for stem diameter growth rate at vegetative growth stage in tomato. (author)

  3. Breast development and anatomy.

    Science.gov (United States)

    Pandya, Sonali; Moore, Richard G

    2011-03-01

    In this article, the development of the female breast, as well as the functional anatomy, blood supply, innervation and lymphatic drainage are described. A thorough understanding of the breast anatomy is an important adjunct to a meticulous clinical breast examination. Breast examination is a complex skill involving key maneuvers, including careful inspection and palpation. Clinical breast examination can provide an opportunity for the clinician to educate patients about their breast and about breast cancer, its symptoms, risk factors, early detection, and normal breast composition, and specifically variability. Clinical breast examination can help to detect some cancers not found by mammography, and clinicians should not override their examination findings if imaging is not supportive of the physical findings.

  4. Breast Reconstruction After Mastectomy

    Science.gov (United States)

    ... Cancer Prevention Genetics of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Reconstruction After Mastectomy On This Page What is breast reconstruction? How do surgeons use implants to reconstruct a woman’s breast? How do surgeons ...

  5. Calibration of the Diameter Distribution Derived from the Area-based Approach with Individual Tree-based Diameter Estimates Using the Airborne Laser Scanning

    Science.gov (United States)

    Xu, Q.; Hou, Z.; Maltamo, M.; Tokola, T.

    2015-12-01

    Diameter distributions of trees are important indicators of current forest stand structure and future dynamics. A new method was proposed in the study to combine the diameter distributions derived from the area-based approach (ABA) and the diameter distribution derived from the individual tree detection (ITD) in order to obtain more accurate forest stand attributes. Since dominant trees can be reliably detected and measured by the Lidar data via the ITD, the focus of the study is to retrieve the suppressed trees (trees that were missed by the ITD) from the ABA. Replacement and histogram matching were respectively employed at the plot level to retrieve the suppressed trees. Cut point was detected from the ITD-derived diameter distribution for each sample plot to distinguish dominant trees from the suppressed trees. The results showed that calibrated diameter distributions were more accurate in terms of error index and the entire growing stock estimates. Compared with the best performer between the ABA and the ITD, calibrated diameter distributions decreased the relative RMSE of the estimated entire growing stock, saw log and pulpwood fractions by 2.81%, 3.05% and 7.73% points respectively. Calibration improved the estimation of pulpwood fraction significantly, resulting in a negligible bias of the estimated entire growing stock.

  6. Bexarotene in Preventing Breast Cancer in Patients at High Risk for Breast Cancer

    Science.gov (United States)

    2018-03-02

    Atypical Ductal Breast Hyperplasia; Atypical Lobular Breast Hyperplasia; BRCA1 Gene Mutation; BRCA2 Gene Mutation; Ductal Breast Carcinoma In Situ; Invasive Breast Carcinoma; Lobular Breast Carcinoma In Situ; No Evidence of Disease

  7. Optimization of Region of Interest Drawing for Quantitative Analysis: Differentiation Between Benign and Malignant Breast Lesions on Contrast-Enhanced Sonography.

    Science.gov (United States)

    Nakata, Norio; Ohta, Tomoyuki; Nishioka, Makiko; Takeyama, Hiroshi; Toriumi, Yasuo; Kato, Kumiko; Nogi, Hiroko; Kamio, Makiko; Fukuda, Kunihiko

    2015-11-01

    This study was performed to evaluate the diagnostic utility of quantitative analysis of benign and malignant breast lesions using contrast-enhanced sonography. Contrast-enhanced sonography using the perflubutane-based contrast agent Sonazoid (Daiichi Sankyo, Tokyo, Japan) was performed in 94 pathologically proven palpable breast mass lesions, which could be depicted with B-mode sonography. Quantitative analyses using the time-intensity curve on contrast-enhanced sonography were performed in 5 region of interest (ROI) types (manually traced ROI and circular ROIs of 5, 10, 15, and 20 mm in diameter). The peak signal intensity, initial slope, time to peak, positive enhancement integral, and wash-out ratio were investigated in each ROI. There were significant differences between benign and malignant lesions in the time to peak (P benign and malignant lesions in the time to peak (P benign and malignant breast lesions. © 2015 by the American Institute of Ultrasound in Medicine.

  8. Delayed breast reconstruction with implants after invasive breast cancer does not impair prognosis

    DEFF Research Database (Denmark)

    Holmich, L.R.; During, M.; Henriksen, T.F.

    2008-01-01

    We investigated if delayed breast implant reconstruction after breast cancer impairs prognosis. Using data from the Danish Breast Cancer Cooperative Group register, we identified all women......We investigated if delayed breast implant reconstruction after breast cancer impairs prognosis. Using data from the Danish Breast Cancer Cooperative Group register, we identified all women...

  9. A rare case of fibrocystic disease at vulval accessory breast tissue.

    Science.gov (United States)

    Das, Sudip; Roy, Alok Kumar; Kar, Chinmoy; Giri, Parag Prasun

    2007-11-01

    A 40-year-old female presented with a non-itchy ulcerative nodular lesion at left labium majus since last 1 1/2 years. The lesion progressed to increase in size from 0.5 cm to 1.5 cm in diameter. It was incised and drained. After that a non-healing ulcerative nodule formed. The nodule was firm in consistency and movable on all sides. The ulcer healed with a 5 days course of ceftriaxone. If was excised and biopsy of the lesion showed fibrocystic changes of accessory breast tissue. It is a rare disease entity for which the case report is presented.

  10. Breast cancer and breast health awareness as an evolving health promotion concept

    International Nuclear Information System (INIS)

    Plesnicar, A.; Kralj, B.; Kovac, V.

    2004-01-01

    Background. Breast cancer is the most frequent malignant disease in the majority of developed countries. In the last few years the introduction of mammography screening programmes has resulted in an improved survival of breast cancer patients. However, the incidence of the disease in these countries is still on the increase. Present focus on secondary breast cancer prevention activities, consisting of early detection and treatment, cannot ensure a decrease of breast cancer incidence. Improved breast health awareness could therefore represent a part of specific health promotion activities aimed at decreasing the incidence of breast cancer. Conclusions. In developed countries breast cancer is a significant health care issue. Secondary breast cancer prevention activities should therefore be complemented by specific health promotion activities in order to reduce its incidence in the future. Primary breast cancer prevention would include health promotion activities aimed at enhancement of the individual as well as collective breast health awareness. Properly enlightened members of the influential population groups could attain appropriate changes in the fields of legislation, taxation, customs and commercial regulations that would enable women to control their own breast health. (author)

  11. Multi-diameter pigging: factors affecting the design and selection of pigging tools for multi-diameter pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, Karl [Pipeline Engineering and Supply Co. Ltd., Richmond, NY (United States)

    2009-07-01

    This paper will consider the process involved in pigging tool selection for pipelines with two or more significant internal diameters which require pigging tools capable of negotiating the different internal diameters whilst also carrying out the necessary pipeline cleaning operation. The paper will include an analysis of pipeline features that affect pigging tool selection and then go on to look at other variables that determine the pigging tool design; this will include a step by step guide outlining how the tool is designed, the development of prototype pigs and the importance of testing and validation prior to final deployment in operational pigging programmes. (author)

  12. Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Chao-Jen, E-mail: cjlai3711@gmail.com; Zhong, Yuncheng; Yi, Ying; Wang, Tianpeng; Shaw, Chris C. [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009 (United States)

    2015-06-15

    Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical

  13. Increasing Breast Cancer Surveillance among African American Breast Cancer Survivors

    National Research Council Canada - National Science Library

    Thompson, Hayley

    2005-01-01

    ...; they also are at considerable risk for breast cancer recurrence. According to the American Society of Clinical Oncology, survivors should undergo careful breast cancer surveillance, including annual mammography and breast self-exam...

  14. The 88-Inch Cyclotron: A One-Stop Facility for Electronics Radiation and Detector Testing

    Energy Technology Data Exchange (ETDEWEB)

    Kireeff Covo, M.; Albright, R. A.; Ninemire, B. F.; Johnson, M. B.; Hodgkinson, A.; Loew, T.; Benitez, J. Y.; Todd, D. S.; Xie, D. Z.; Perry, T.; Phair, L.; Bernsteiny, L. A.; Bevins, J.; Brown, J. A.; Goldblum, B. L.; Harasty, M.; Harrig, K. P.; Laplace, T. A.; Matthews, E. F.; Bushmaker, A.; Walker, D.; Oklejas, V.; Hopkins, A. R.; Bleuel, D. L.; Chen, J.; Cronin, S. B.

    2017-10-01

    In outer space down to the altitudes routinely flown by larger aircrafts, radiation can pose serious issues for microelectronics circuits. The 88-Inch Cyclotron at Lawrence Berkeley National Laboratory is a sector-focused cyclotron and home of the Berkeley Accelerator Space Effects Facility, where the effects of energetic particles on sensitive microelectronics are studied with the goal of designing electronic systems for the space community. This paper describes the flexibility of the facility and its capabilities for testing the bombardment of electronics by heavy ions, light ions, and neutrons. Experimental capabilities for the generation of neutron beams from deuteron breakups and radiation testing of carbon nanotube field effect transistor will be discussed.

  15. Heritability of retinal vessel diameters and blood pressure

    DEFF Research Database (Denmark)

    Taarnhøj, Nina C B B; Larsen, Michael; Sander, Birgit

    2006-01-01

    PURPOSE: To assess the relative influence of genetic and environmental effects on retinal vessel diameters and blood pressure in healthy adults, as well as the possible genetic connection between these two characteristics. METHODS: In 55 monozygotic and 50 dizygotic same-sex healthy twin pairs......%-80%) for CRAE, 83% (95% CI: 73%-89%) for CRVE, and 61% (95% CI: 44%-73%) for mean arterial blood pressure (MABP). Retinal artery diameter decreased with increasing age and increasing arterial blood pressure. Mean vessel diameters in the population were 165.8 +/- 14.9 microm for CRAE, 246.2 +/- 17.7 microm...... for CRVE, and 0.67 +/- 0.05 microm for AVR. No significant influence on artery or vein diameters was found for gender, smoking, body mass index (BMI), total cholesterol, fasting blood glucose, or 2-hour oral glucose tolerance test values. CONCLUSIONS: In healthy young adults with normal blood pressure...

  16. Awareness of breast cancer and breast self-examination among ...

    African Journals Online (AJOL)

    Awareness of breast cancer and breast self-examination among female undergraduate students in a higher teachers training college in Cameroon. ... Conclusion: Though most students are aware of the existence of breast cancer, their overall knowledge on its risk factors and clinical presentation is insufficient with a ...

  17. Breast cancer screening (breast self-examination, clinical breast exam, and mammography) in women referred to health centers in Tabriz, Iran.

    Science.gov (United States)

    Khalili, Azizeh Farshbaf; Shahnazi, Mahnaz

    2010-04-01

    Breast cancer is the most common cancer and the most common cause of death in Iranian women aged 35-55 years. Breast cancer screening comprises breast self-examination (BSE), clinical breast examination (CBE) and mammography. The study aimed to examine the performance of screening methods among women referring to health centers of Tabriz, Iran. This was a descriptive-analytical research carried out on 400 women aged 20-50 years. The samples were chosen through random multistage sampling among health centers of Tabriz then active records of women. A questionnaire and observational checklist was used to elicit socio-demographic information and performance of women towards breast cancer screening methods. Descriptive and inferential statistics (chi-square and Fisher's exact test) were used to analyze the data. Only 18.8% of women did breast self-examination, 19.1% had clinical breast examination and 3.3% had mammogram. Statistical test showed a significant relationship between performing BSE and educational level, employment, income, number of children, breastfeeding history, breastfeeding quality and family history of breast cancer. There was a significant correlation between performing CBE and history of breast tumor and also, between performing the mammography and family history of breast cancer and history of breast tumor (P pre marriage counseling periods seems necessary.

  18. Concurrent breast stroma sarcoma and breast carcinoma: a case report

    Directory of Open Access Journals (Sweden)

    Carvalho Teresa

    2010-12-01

    Full Text Available Abstract Introduction Breast cancer is one of the most important health problems in the world and affects a great number of women over the entire globe. This group of tumors rarely presents as bilateral disease and, when it does happen, normally occurs within the same histological type. We report a rare case of concurrent bilateral breast cancer with two different histology types, a breast carcinoma and a breast sarcoma, in a 42-year-old woman referred to our hospital. Case presentation A 42-year-old Caucasian woman admitted to our institute in August 1999, presented with a nodule in the left breast of 3.0 × 2.5 cm, and, in the right breast, one of 1.0 cm, suspected of malignancy and with a clinically negative armpit. Biopsies had revealed invasive mammary carcinoma (right breast and sarcoma (left breast. She was submitted to bilateral modified radical mastectomy. A histological study showed an invasive mammary carcinoma degree II lobular pleomorphic type with invasion of seven of the 19 excised axillary nodes in the right breast and, in the left breast, a sarcoma of the mammary stroma, for which the immunohistochemistry study was negative for epithelial biomarkers and positive for vimentin. Later, she was submitted for chemotherapy (six cycles of 75 mg/m2 5-fluorouracil, epirubicin and cyclophosphamide followed by radiotherapy of the thoracic wall and axillary nodes on the left. Hormone receptors were positive in the tumor of the right breast, and tamoxifen, 20 mg, was prescribed on a daily basis (five years followed by letrozole, 2.5 mg, also daily (five years. She presented no sign of negative evolution in the last consultation. Conclusion The risk of development of bilateral breast cancer is about 1% each year within a similar histological type, but it is higher in tumors with lobular histology. In this case, the patient presented, simultaneously, two histologically distinct tumors, thus evidencing a rare situation.

  19. Lumbar Vertebral Canal Diameters in Adult Ugandan Skeletons ...

    African Journals Online (AJOL)

    Background: Normal values of lumbar vertebral canal diameters are useful in facilitating diagnosis of lumbar vertebral canal stenosis. Various studies have established variation on values between different populations, gender, age, and ethnic groups. Objectives: To determine the lumbar vertebral canal diameters in adult ...

  20. Analysis of ATLAS 6-inch cold leg break simulation with MARS-KS code

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Se Yun; Jun, Hwang Yong; Ha, Sang Jun [Korea Electric Power Company, Daejeon (Korea, Republic of)

    2011-05-15

    A Domestic Standard Problem (DSP) exercise using ATLAS facility has been organized by KAERI. As the second DSP exercise, the 6-inch cold leg bottom break was determined. This experiment is the counterpart test to the DVI line break to verify the safety performance of the DVI method over the traditional CLI method. Compared with the large break LOCA, the phases of the small break LOCA prior to core recovery occur over a long period. The blowdown, natural circulation, loop seal clearance, boil-off, and core recovery phase should be investigated minutely with relevant models of safety analysis codes in order to predict these thermal hydraulic phenomena correctly. To investigate the ECC bypass phenomena, a finer study on the thermalhydraulic behavior in upper annulus downcomer was carried out

  1. Moisture monitoring in large diameter boreholes

    International Nuclear Information System (INIS)

    Tyler, S.

    1985-01-01

    The results of both laboratory and field experiments indicate that the neutron moisture gauge traditionally used in soil physics experiments can be extended for use in large diameter (up to 15 cm) steel-cased boreholes with excellent results. This application will permit existing saturated zone monitoring wells to be used for unsaturated zone monitoring of recharge, redistribution and leak detection from waste disposal facilities. Its applicability to large diameter cased wells also gives the soil physicist and ground-water hydrologist and new set of monitoring points in the unsaturated zone to study recharge and aquifer properties. 6 refs., 6 figs., 2 tabs

  2. Diameter dependent failure current density of gold nanowires

    International Nuclear Information System (INIS)

    Karim, S; Maaz, K; Ali, G; Ensinger, W

    2009-01-01

    Failure current density of single gold nanowires is investigated in this paper. Single wires with diameters ranging from 80 to 720 nm and length 30 μm were electrochemically deposited in ion track-etched single-pore polycarbonate membranes. The maximum current density was investigated while keeping the wires embedded in the polymer matrix and ramping up the current until failure occurred. The current density is found to increase with diminishing diameter and the wires with a diameter of 80 nm withstand 1.2 x 10 12 A m -2 before undergoing failure. Possible reasons for these results are discussed in this paper.

  3. Reduced arterial diameter during static exercise in humans

    DEFF Research Database (Denmark)

    Olesen, H L; Mitchell, J H; Friedman, D B

    1995-01-01

    In eight subjects luminal diameter of the resting limb radial and dorsalis pedis arteries was determined by high-resolution ultrasound (20 MHz). This measurement was followed during rest and during 2 min of static handgrip or of one-leg knee extension at 30% of maximal voluntary contraction...... exertion was approximately 15 units after both types of exercise. The dorsalis pedis arterial diameter was 1.50 +/- 0.20 mm (mean and SE) and the radial AD 2.45 +/- 0.12 mm. During both types of contractions the luminal diameters decreased approximately 3.5% within the first 30 s (P

  4. Effective diameters and corresponding states of fluids

    Science.gov (United States)

    Del Río, Fernando

    Effective hard-sphere diameters of fluids with purely repulsive interactions are derived from a generalized corresponding-states principle of Leland, Rowlinson and coworkers. Various alternative definitions are discussed and related. Virial expansions of the effective diameters and their corresponding volumes are obtained and compared with results of perturbation theory. Applications are made to inverse-power potentials, the repulsive part of the Lennard-Jones potential and hard spherocylinders and dumbells.

  5. Ultrasound imaging-guided intracardiac injection to develop a mouse model of breast cancer brain metastases followed by longitudinal MRI.

    Science.gov (United States)

    Zhou, Heling; Zhao, Dawen

    2014-03-06

    Breast cancer brain metastasis, occurring in 30% of breast cancer patients at stage IV, is associated with high mortality. The median survival is only 6 months. It is critical to have suitable animal models to mimic the hemodynamic spread of the metastatic cells in the clinical scenario. Here, we are introducing the use of small animal ultrasound imaging to guide an accurate injection of brain tropical breast cancer cells into the left ventricle of athymic nude mice. Longitudinal MRI is used to assessing intracranial initiation and growth of brain metastases. Ultrasound-guided intracardiac injection ensures not only an accurate injection and hereby a higher successful rate but also significantly decreased mortality rate, as compared to our previous manual procedure. In vivo high resolution MRI allows the visualization of hyperintense multifocal lesions, as small as 310 µm in diameter on T2-weighted images at 3 weeks post injection. Follow-up MRI reveals intracranial tumor growth and increased number of metastases that distribute throughout the whole brain.

  6. Comparison between transcerebellar diameter with biparietal diameter of ultrasound for gestational age measurement in third trimester of pregnancy

    International Nuclear Information System (INIS)

    Naseem, F.; Fatima, N.; Yasmeen, S.; Saleem, S.

    2013-01-01

    To determine the frequency of correct assessment by transcerebeller diameter (TCD) versus biparietal diameter (BPD) for gestational age measurement at 36 weeks of pregnancy using first day of last menstrual period (LMP) for actual period of gestation. Study Design: Quasi experimental. Place and Duration of Study: Department of Obstetrics and Gynaecology, Bahawal Victoria Hospital, Bahawalpur from May to November 2010. Methodology: This study was performed on 228 patients at 36 weeks of pregnancy fulfilling the inclusion criteria. Ultrasound measurements of TCD and BPD was made and compared with LMP. Collected data was analyzed by SPSS version 10. Proportoin of correct diagnosis by each measurement was determined and compared using chi-square test with significance at p < 0.05. Results: Out of 228 patients, TCD was found to give correct assessment in 209 patients (91.7%; p = 0.001) corresponding to the gestational age by LMP i.e 36 weeks. BPD was found to give correct assessment corresponding to the gestational age by LMP in 176 patients (77.2%). Conclusion: Although both BPD and TCD are accurate biometric parameters at 36 weeks of gestation, transcerebellar diameter is more reliable method of gestational age determination in third trimester of pregnancy than biparietal diameter. TCD can be used as a tool to assist in the assessment of gestational age in third trimester. (author)

  7. Performance differences when using 26- and 29-inch-wheel bikes in Swiss National Team cross-country mountain bikers.

    Science.gov (United States)

    Steiner, Thomas; Müller, Beat; Maier, Thomas; Wehrlin, Jon Peter

    2016-08-01

    The purpose of this study was to analyse the effect of bike type - the 26-inch-wheel bike (26" bike) and the 29-inch-wheel bike (29" bike) - on performance in elite mountain bikers. Ten Swiss National Team athletes (seven males, three females) completed six trials with individual start on a simulated cross-country course with 35 min of active recovery between trials (three trials on a 26" bike and three trials on a 29" bike, alternate order, randomised start-bike). The course consisted of two separate sections expected to favour either the 29" bike (section A) or the 26" bike (section B). For each trial performance, power output, cadence and heart rate were recorded and athletes' experiences were documented. Mean overall performance (time: 304 ± 27 s vs. 311 ± 29 s; P < 0.01) and performance in sections A (P < 0.001) and B (P < 0.05) were better when using the 29" bike. No significant differences were observed for power output, cadence or heart rate. Athletes rated the 29" bike as better for performance in general, passing obstacles and traction. The 29" bike supports superior performance for elite mountain bikers, even on sections supposed to favour the 26" bike.

  8. Evaluation of a mass screening of breast cancer with mammography in personnel of regional public schools

    International Nuclear Information System (INIS)

    Saito, Yoshihiro; Muto, Taisei; Asanuma, Taku; Horikoshi, Akira; Tsuchihara, Katsuo

    2009-01-01

    We have examined a total of 15,224 women in our hospital aiming at a mass screening of breast cancer with mammography (MMG) during the last 8 years. Subjected women were teachers or staffs of public schools in six prefectures in the Tohoku area. More than 90% of them were under 50 years old and women younger than 49 accounted for about half of them. A recall rate was 3.8%, and breast cancer was found in 55 women (0.36%) and the ratio of cancers diagnosed among recalled women was 9.5%. Twenty-one point eight percent of detected cancers were associated with calcification. The average diameter of the detected tumors in the screening group was 1.6 cm, whereas that of outpatients (controls) was 2.5 cm. Stage 0 and I cancer cases in the screening group accounted for 82.0%, whereas those in the outpatient group, 49.6%, indicating a significant increase in detection rate of early breast cancer in the screening compared to the outpatients group. However, detection rate of breast masses was 76.7% of all cases of breast tumor by means of MMG, versus 86.0% by means of physical examination. These results suggest that the mass screening by using physical examination and MMG, as well as ultrasonography, may provide a better clinical application for precise diagnosis, when it is done for working women in the regional public schools who are younger. (author)

  9. Common breast cancer susceptibility loci are associated with triple negative breast cancer

    Science.gov (United States)

    Stevens, Kristen N.; Vachon, Celine M.; Lee, Adam M.; Slager, Susan; Lesnick, Timothy; Olswold, Curtis; Fasching, Peter A.; Miron, Penelope; Eccles, Diana; Carpenter, Jane E.; Godwin, Andrew K.; Ambrosone, Christine; Winqvist, Robert; Schmidt, Marjanka K.; Cox, Angela; Cross, Simon S.; Sawyer, Elinor; Hartmann, Arndt; Beckmann, Matthias W.; Schulz-Wendtland, Rüdiger; Ekici, Arif B.; Tapper, William J; Gerty, Susan M; Durcan, Lorraine; Graham, Nikki; Hein, Rebecca; Nickels, Stephan; Flesch-Janys, Dieter; Heinz, Judith; Sinn, Hans-Peter; Konstantopoulou, Irene; Fostira, Florentia; Pectasides, Dimitrios; Dimopoulos, Athanasios M.; Fountzilas, George; Clarke, Christine L.; Balleine, Rosemary; Olson, Janet E.; Fredericksen, Zachary; Diasio, Robert B.; Pathak, Harsh; Ross, Eric; Weaver, JoEllen; Rüdiger, Thomas; Försti, Asta; Dünnebier, Thomas; Ademuyiwa, Foluso; Kulkarni, Swati; Pylkäs, Katri; Jukkola-Vuorinen, Arja; Ko, Yon-Dschun; Van Limbergen, Erik; Janssen, Hilde; Peto, Julian; Fletcher, Olivia; Giles, Graham G.; Baglietto, Laura; Verhoef, Senno; Tomlinson, Ian; Kosma, Veli-Matti; Beesley, Jonathan; Greco, Dario; Blomqvist, Carl; Irwanto, Astrid; Liu, Jianjun; Blows, Fiona M.; Dawson, Sarah-Jane; Margolin, Sara; Mannermaa, Arto; Martin, Nicholas G.; Montgomery, Grant W; Lambrechts, Diether; dos Santos Silva, Isabel; Severi, Gianluca; Hamann, Ute; Pharoah, Paul; Easton, Douglas F.; Chang-Claude, Jenny; Yannoukakos, Drakoulis; Nevanlinna, Heli; Wang, Xianshu; Couch, Fergus J.

    2012-01-01

    Triple negative breast cancers are an aggressive subtype of breast cancer with poor survival, but there remains little known about the etiological factors which promote its initiation and development. Commonly inherited breast cancer risk factors identified through genome wide association studies (GWAS) display heterogeneity of effect among breast cancer subtypes as defined by estrogen receptor (ER) and progesterone receptor (PR) status. In the Triple Negative Breast Cancer Consortium (TNBCC), 22 common breast cancer susceptibility variants were investigated in 2,980 Caucasian women with triple negative breast cancer and 4,978 healthy controls. We identified six single nucleotide polymorphisms (SNPs) significantly associated with risk of triple negative breast cancer, including rs2046210 (ESR1), rs12662670 (ESR1), rs3803662 (TOX3), rs999737 (RAD51L1), rs8170 (19p13.11) and rs8100241 (19p13.11). Together, our results provide convincing evidence of genetic susceptibility for triple negative breast cancer. PMID:21844186

  10. Breast Cancer Screening

    International Nuclear Information System (INIS)

    Altaf, Fadwa J.

    2004-01-01

    Breast cancer is a very common health problem in Saudi females that can be reduced by early detection through introducing breast cancer screening. Literature review reveals significant reduction in breast cancer incidence and outcome after the beginning of breast cancer screening. The objectives of this article are to highlight the significance of breast cancer screening in different international societies and to write the major guidelines of breast cancer screening in relation to other departments involved with more emphasis on the Pathology Department guidelines in tissue handling, diagnostic criteria and significance of the diagnosis. This article summaries and acknowledges major work carried out before, and recommends similar modified work in order to meet the requirement for the Saudi society. (author)

  11. Polydimethylsiloxane: a new contrast material for localization of occult breast lesions

    International Nuclear Information System (INIS)

    Vitral, Geraldo Sérgio Farinazzo; Raposo, Nádia Rezende Barbosa

    2011-01-01

    The radioguided localization of occult breast lesions (ROLL) technique often utilizes iodinated radiographic contrast to assure that the local injection of 99m Tc-MAA corresponds to the location of the lesion under investigation. However, for this application, this contrast has several shortcomings. The objective of this study was to evaluate the safety, effectiveness and technical feasibility of the use of polydimethylsiloxane (PDMS) as radiological contrast and tissue marker in ROLL. The safety assessment was performed by the acute toxicity study in Wistar rats (n = 50). The radiological analysis of breast tissue (n = 32) from patients undergoing reductive mammoplasty was used to verify the effectiveness of PDMS as contrast media. The technical feasibility was evaluated through the scintigraphic and histologic analysis. We found no toxic effects of PDMS for this use during the observational period. It has been demonstrated in human breast tissue that the average diameter of the tissue marked by PDMS was lower than when marked by the contrast medium (p <0.001). PDMS did not interfere with the scintigraphic uptake (p = 0.528) and there was no injury in histological processing of samples. This study demonstrated not only the superiority of PDMS as radiological contrast in relation to the iodinated contrast, but also the technical feasibility for the same applicability in the ROLL

  12. Heritability of optic disc diameters: a twin study

    DEFF Research Database (Denmark)

    Drobnjak, Dragana; Taarnhøj, Nina Charlotte; Mitchell, Paul

    2011-01-01

    , additive genetic factors (i.e. heritability) explained 77% (95% CI: 65-85%) of variation of vertical disc diameters, whereas estimated unshared environmental effect was 23% (95% CI: 15-35%). For vertical cup diameters, heritability accounted for 70% (95% CI: 55-80%) and environmental factors 30% (95% CI...

  13. Breast-Conserving Surgery Followed by Radiation Therapy With MRI-Detected Stage I or Stage II Breast Cancer

    Science.gov (United States)

    2011-12-07

    Ductal Breast Carcinoma in Situ; Estrogen Receptor-negative Breast Cancer; Estrogen Receptor-positive Breast Cancer; HER2-negative Breast Cancer; HER2-positive Breast Cancer; Invasive Ductal Breast Carcinoma; Invasive Lobular Breast Carcinoma; Male Breast Cancer; Medullary Ductal Breast Carcinoma With Lymphocytic Infiltrate; Mucinous Ductal Breast Carcinoma; Papillary Ductal Breast Carcinoma; Progesterone Receptor-negative Breast Cancer; Progesterone Receptor-positive Breast Cancer; Stage I Breast Cancer; Stage II Breast Cancer; Tubular Ductal Breast Carcinoma

  14. Pattern of breast diseases: preliminary report of breast clinic

    International Nuclear Information System (INIS)

    Siddiqui, K.; Rasool, I.

    2001-01-01

    Objective: To find out the pattern of breast disease in this part of the county and create public awareness about breast diseases especially cancer. Design: Ac cross sectional and cohort study. Place and Duration of Study: The study was conducted at Department of Surgery, Jinnah Hospital /Allama Iqbal Medical College, Lahore from March 1999 to July 2000. Subjects and Methods: All the female patients reported were included in this study. They were diagnosed by history, physical examination and rel event investigations like ultrasonography, mammography, FNAS and biopsy. Appropriate medical and surgical management was carried out. The breast cancer was treated according to TNA staging system by multidisciplinary approach. Method of breast self examination (BSE) was taught with the help of charts and brochures. Results: The age ranged from 10 years to 75 years. Maximum number of patients (30%) was seen between 20-29 years of age while 15 (1%) cases did not suffer from any disease. Among 1485 patients the common conditions were non cyclical mastalgia in 362 (24.37%), fibroadenoma in 289 (19.46%), fibrocystic disease in 276(17.98%) breast abscess in 149 (10%) and breast cancer (6.19%). Other diseases were puberty mastitis 49(3.2%), galactocele 40(2.69%), accessory breast 45(3%) and nipple discharge 28(1.88%). Among the palpable lumps, breast caner accounted for 11.75%. The commonest age of presentation of breast cancer was 5th decade (31%) followed by 4th decade (26%). Majority of cancer patients (45%) presented in stage III. All the women with beast abscesses were lactating. Non cyclical mastalgia was commonly seen in 4th decade (30.66%) while 44.63% patients of fibroadenoma reported in the 2nd decade. Fibrocystic disease was reported between 3rd and 4th decade (62.17%). Conclusion: Commonest being conditions were non cyclical mastalgia followed by fibroadenoma while breast cancer contributed a significant percentage of palpable lumps. Due to effective public awareness

  15. Localized morphea after breast implant for breast cancer: A case report.

    Science.gov (United States)

    Moretti, A; Bianchi, F; Abbate, I V; Gherardi, G; Bonavita, M; Passoni, E; Nazzaro, G; Bramati, A; Dazzani, M C; Piva, S; Paternò, E; Frungillo, N; Farina, G; La Verde, N

    2018-03-01

    Early breast cancer follow-up guidelines for patients who underwent surgery suggest a regular and accurate clinical examination of the breast area, for an early identification of cutaneous or subcutaneous breast cancer relapse. Nonetheless, breast skin lesions arising in patients treated with mastectomy for breast cancer can be caused by several diseases. A series of diagnostic hypotheses should be considered, not only focusing on cutaneous metastasis, but also on dermatologic and systemic diseases. In February 2015, a 37-year-old patient underwent a right subcutaneous mastectomy for stage IIA breast cancer. Five months after beginning adjuvant chemotherapy, she noted hyperpigmentation and thickening of the skin on the right breast. Differential diagnosis included local relapse, skin infection, lymphoma, or primary cutaneous disease, and a skin biopsy was performed. The histopathologic specimen showed full-thickness sclerosis, with features of localized morphea. Therapy with clobetasol was prescribed, with progressive resolution of the thickness. The collaboration between many professionals in a multidisciplinary team (oncologist, dermatologist, plastic surgeon, and pathologist) was crucial to achieving the diagnosis. In the literature, some articles describe correlation between connective tissue diseases and silicone breast implants, but the pathogenetic mechanisms are unknown. We report a rare case of breast morphea after positioning a silicone implant in a patient who had undergone mastectomy. This clinical report represents an interesting model of multidisciplinary management of a patient with breast cancer who developed an uncommon dermatologic disease. Further studies are needed to clarify the association between silicone implants and breast morphea.

  16. Primary Angiosarcoma of the Breast after Bilateral Breast Reduction

    Directory of Open Access Journals (Sweden)

    Justus Philip

    2018-01-01

    Full Text Available Angiosarcoma of the breast is a rare malignancy of endothelial cell origin, representing less than 1% of all breast malignancy. Primary angiosarcomas can occur in the setting of chronic lymphedema, but it also may occur spontaneously without any preceding treatment. Surgery is the primary therapeutic intervention for breast angiosarcomas with radiation and chemotherapy as adjuvant treatment. Angiosarcomas are aggressive and tend to have a high risk of local and metastatic recurrence. We present a case of primary angiosarcoma that developed in a patient who had bilateral breast reduction surgery in the past.

  17. Brain Arterial Diameters as a Risk Factor for Vascular Events.

    Science.gov (United States)

    Gutierrez, Jose; Cheung, Ken; Bagci, Ahmet; Rundek, Tatjana; Alperin, Noam; Sacco, Ralph L; Wright, Clinton B; Elkind, Mitchell S V

    2015-08-06

    Arterial luminal diameters are routinely used to assess for vascular disease. Although small diameters are typically considered pathological, arterial dilatation has also been associated with disease. We hypothesize that extreme arterial diameters are biomarkers of the risk of vascular events. Participants in the Northern Manhattan Study who had a time-of-flight magnetic resonance angiography were included in this analysis (N=1034). A global arterial Z-score, called the brain arterial remodeling (BAR) score, was obtained by averaging the measured diameters within each individual. Individuals with a BAR score -2 and 2 SDs had the largest diameters. All vascular events were recorded prospectively after the brain magnetic resonance imaging. Spline curves and incidence rates were used to test our hypothesis. The association of the BAR score with death (P=0.001), vascular death (P=0.02), any vascular event (P=0.05), and myocardial infarction (P=0.10) was U-shaped except for ischemic stroke (P=0.74). Consequently, incidence rates for death, vascular death, myocardial infarction, and any vascular event were higher in individuals with the largest diameters, whereas individuals with the smallest diameters had a higher incidence of death, vascular death, any vascular event, and ischemic stroke compared with individuals with average diameters. The risk of death, vascular death, and any vascular event increased at both extremes of brain arterial diameters. The pathophysiology linking brain arterial remodeling to systemic vascular events needs further research. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  18. MRI evaluation of the contralateral breast in patients with recently diagnosed breast cancer

    International Nuclear Information System (INIS)

    Taneja, Sangeeta; Jena, Amarnath; Zaidi, Syed Mohd. Shuaib; Khurana, Anuj

    2012-01-01

    Contralateral breast cancer can be synchronous and/or metachronous in patients with cancer of one breast. Detection of a synchronous breast cancer may affect patient management. Dynamic contrast-enhanced MRI of the breast (DCE-MRI) is a sensitive technique for detecting contralateral lesions occult on the other imaging modalities in women already diagnosed with cancer of one breast. The aim was to assess the incidence of mammographically occult synchronous contralateral breast cancer in patients undergoing MRI mammography for the evaluation of a malignant breast lesion. A total of 294 patients with recently diagnosed breast cancer who underwent MRI of the breast were evaluated for lesions in the opposite breast. The incidence of synchronous contralateral malignancy detected by preoperative MRI mammography done for evaluation of extent of disease was 4.1%. Preoperative breast MRI may detect clinically and mammographically occult synchronous contralateral cancer, and can help the patient avoid an additional second surgery or a second course of chemotherapy later; also, as theoretically these lesions are smaller, there may be a survival benefit as well

  19. Comparative study of diagnostic efficiency of mammography and ultrasonography for breast cancer

    International Nuclear Information System (INIS)

    Koike, Yasuo; Terai, Naoki; Wakabayashi, Toru; Tsuchiya, Shin-ichi

    1995-01-01

    We performed a study of 448 women with breast cancer who visited the breast clinic of Nagano Cancer Center, and underwent mammography (MMG) and ultrasonography (US) at the last examination, between October 1983 and December 1993. These women subsequently underwent surgery at several hospitals after referral from our center. Definitive diagnoses of breast cancer were made histopathologically. Both MMG and US findings were graded using five-step criteria (indicating the level of malignancy) from I (normal) to V (definite malignancy). The diagnostic efficiencies of the two examinations were then compared clinicopathologically. Furthermore, on the basis of the results obtained, we considered supplemental diagnostic methods that could be introduced for mass screening of breast cancer. There was a significant difference between the incidence of cases diagnosed as V IV III b (malignancy) by US (71.9%) and those diagnosed by MMG (60.9%). Among cases suspected to be breast cancer by palpation, the proportion diagnosed as V IV III b (malignancy) by US (83.3%) was significantly higher than that diagnosed by MMG (73.7%). Among cases suspected to be mastopathy by palpation, the proportion diagnosed as malignant by US was higher than that diagnosed by MMG. The false negativity rate for palpation combined with MMG was higher than that for palpation with US. Among cases without palpable masses, the proportion diagnosed as malignant by MMG was higher than that diagnosed by US. However, for palpable tumors less than 5.0 cm in diameter, the proportion of cases diagnosed as malignant by US was higher than that diagnosed by MMG. In terms of the gross appearance of the cut surface, grade of cancer invasion, histological type and grade of chubbiness, the diagnostic efficiency of US was shown to be slightly better than that of MMG. The above results suggest that US should be considered as a supplemental method for introduction to mass screening of breast cancer. (author)

  20. Design evaluation of the 20-cm (8-inch) secondary burner system

    International Nuclear Information System (INIS)

    Rode, J.S.

    1977-08-01

    This report describes an evaluation of the design of the existing 20-cm (8-inch) engineering-scale secondary burner system in the HTGR reprocessing cold pilot plant at General Atomic Co. The purpose of this evaluation is to assess the suitability of the existing design as a prototype of the HTGR Recycle Demonstration Facility (HRDF) secondary burner system and to recommend alternatives where the existing design is thought to be unsuitable as a prototype. This evaluation has led to recommendations for the parallel development of two integrated design concepts for a prototype secondary burner system. One concept utilizes the existing burner heating and cooling subsystems in order to minimize development risk, but simplifies a number of other features associated with remote maintenance and burner operation. The other concept, which offers maximum cost reduction, utilizes internal gas cooling of the burner, retains the existing heating subsystem for design compatibility, but requires considerable development to reduce the risk to acceptable limits. These concepts, as well as other design alternatives, are described and evaluated

  1. Primary breast osteosarcoma mimicking calcified fibroadenoma on screening digital breast tomosynthesis mammogram

    Directory of Open Access Journals (Sweden)

    Debbie Lee Bennett, MD

    2017-12-01

    Full Text Available Primary breast osteosarcoma is a rare malignancy, with mostly case reports in the literature. The appearance of breast osteosarcoma on digital breast tomosynthesis imaging has not yet been described. A 69-year-old woman presents for routine screening mammography and is found to have a calcified mass in her right breast. Pattern of calcification appeared “sunburst” on digital breast tomosynthesis images. This mass was larger than on the previous year's mammogram, at which time it had been interpreted as a benign calcified fibroadenoma. The subsequent workup demonstrated the mass to reflect primary breast osteosarcoma. The patient's workup and treatment are detailed in this case. Primary breast osteosarcoma, although rare, should be included as a diagnostic consideration for breast masses with a sunburst pattern of calcifications, particularly when the mammographic appearance has changed.

  2. 30 GHz monolithic balanced mixers using an ion-implanted FET-compatible 3-inch GaAs wafer process technology

    Science.gov (United States)

    Bauhahn, P.; Contolatis, A.; Sokolov, V.; Chao, C.

    1986-01-01

    An all ion-implanted Schottky barrier mixer diode which has a cutoff frequency greater than 1000 GHz has been developed. This new device is planar and FET-compatible and employs a projection lithography 3-inch wafer process. A Ka-band monolithic balanced mixer based on this device has been designed, fabricated and tested. A conversion loss of 8 dB has been measured with a LO drive of 10 dBm at 30 GHz.

  3. The clinical course of immediate breast implant reconstruction after breast cancer

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Friis, Søren; Frederiksen, Kirsten

    2011-01-01

    The number of women suitable for breast conserving treatment as well as immediate reconstruction after breast cancer has been increasing, and studies of complications hereafter are needed.......The number of women suitable for breast conserving treatment as well as immediate reconstruction after breast cancer has been increasing, and studies of complications hereafter are needed....

  4. Awareness of Breast Cancer and Practice of Breast Self ...

    African Journals Online (AJOL)

    Background and Objective: Breast cancer is the commonest cancer among women in globally and in Nigeria. In Nigeria, cases of breast cancer cases have been prevalent for three decades and more than 90% of cases can be detected by women themselves through breast self – examination. The objective of this study ...

  5. DEGRO practical guidelines. Radiotherapy of breast cancer I. Radiotherapy following breast conserving therapy for invasive breast cancer

    International Nuclear Information System (INIS)

    Sedlmayer, F.

    2013-01-01

    Background and purpose: The aim of the present paper is to update the practical guidelines for postoperative adjuvant radiotherapy of breast cancer published in 2007 by the breast cancer expert panel of the German Society for Radiooncology (Deutsche Gesellschaft fuer Radioonkologie, DEGRO). The present recommendations are based on a revision of the German interdisciplinary S-3 guidelines published in July 2012. Methods: A comprehensive survey of the literature concerning radiotherapy following breast conserving therapy (BCT) was performed using the search terms 'breast cancer', 'radiotherapy', and 'breast conserving therapy'. Data from lately published meta-analyses, recent randomized trials, and guidelines of international breast cancer societies, yielding new aspects compared to 2007, provided the basis for defining recommendations according to the criteria of evidence-based medicine. In addition to the more general statements of the DKG (Deutsche Krebsgesellschaft), this paper addresses indications, target definition, dosage, and technique of radiotherapy of the breast after conservative surgery for invasive breast cancer. Results: Among numerous reports on the effect of radiotherapy during BCT published since the last recommendations, the recent EBCTCG report builds the largest meta-analysis so far available. In a 15 year follow-up on 10,801 patients, whole breast irradiation (WBI) halves the average annual rate of disease recurrence (RR 0.52, 0.48-0.56) and reduces the annual breast cancer death rate by about one sixth (RR 0.82, 0.75-0.90), with a similar proportional, but different absolute benefit in prognostic subgroups (EBCTCG 2011). Furthermore, there is growing evidence that risk-adapted dose augmentation strategies to the tumor bed as well as the implementation of high precision RT techniques (e.g., intraoperative radiotherapy) contribute substantially to a further reduction of local relapse rates. A main focus of ongoing research lies in partial breast

  6. Breast Cancer Immunotherapy

    Institute of Scientific and Technical Information of China (English)

    Juhua Zhou; Yin Zhong

    2004-01-01

    Breast cancer is a leading cause of cancer-related deaths in women worldwide. Although tumorectomy,radiotherapy, chemotherapy and hormone replacement therapy have been used for the treatment of breast cancer, there is no effective therapy for patients with invasive and metastatic breast cancer. Immunotherapy may be proved effective in treating patients with advanced breast cancer. Breast cancer immunotherapy includes antibody based immunotherapy, cancer vaccine immunotherapy, adoptive T cell transfer immunotherapy and T cell receptor gene transfer immunotherapy. Antibody based immunotherapy such as the monoclonal antibody against HER-2/neu (trastuzumab) is successfully used in the treatment of breast cancer patients with over-expressed HER-2/neu, however, HER-2/neu is over-expressed only in 25-30% of breast cancer patients. Cancer vaccine immunotherapy is a promising method to treat cancer patients. Cancer vaccines can be used to induce specific anti-tumor immunity in breast cancer patients, but cannot induce objective tumor regression. Adoptive T cell transfer immunotherapy is an effective method in the treatment of melanoma patients. Recent advances in anti-tumor T cell generation ex vivo and limited clinical trial data have made the feasibility of adoptive T cell transfer immunotherapy in the treatment of breast cancer patients. T cell receptor gene transfer can redirect the specificity of T cells. Chimeric receptor, scFv(anti-HER-2/neu)/zeta receptor, was successfully used to redirect cytotoxic T lymphocyte hybridoma cells to obtain anti-HER-2/neu positive tumor cells, suggesting the feasibility of treatment of breast cancer patients with T cell receptor gene transfer immunotherapy. Clinical trials will approve that immunotherapy is an effective method to cure breast cancer disease in the near future.

  7. Breast Cancer Immunotherapy

    Institute of Scientific and Technical Information of China (English)

    JuhuaZhou; YinZhong

    2004-01-01

    Breast cancer is a leading cause of cancer-related deaths in women worldwide. Although tumorectomy, radiotherapy, chemotherapy and hormone replacement therapy have been used for the treatment of breast cancer, there is no effective therapy for patients with invasive and metastatic breast cancer. Immunotherapy may be proved effective in treating patients with advanced breast cancer. Breast cancer immunotherapy includes antibody based immunotherapy, cancer vaccine immunotherapy, adoptive T cell transfer immunotherapy and T cell receptor gene transfer immunotherapy. Antibody based immunotherapy such as the monoclonal antibody against HER-2/neu (trastuzumab) is successfully used in the treatment of breast cancer patients with over-expressed HER-2/neu, however, HER-2/neu is over-expressed only in 25-30% of breast cancer patients. Cancer vaccine immunotherapy is a promising method to treat cancer patients. Cancer vaccines can be used to induce specific anti-tumor immunity in breast cancer patients, but cannot induce objective tumor regression. Adoptive T cell transfer immunotherapy is an effective method in the treatment of melanoma patients. Recent advances in anti-tumor T cell generation ex vivo and limited clinical trial data have made the feasibility of adoptive T cell transfer immunotherapy in the treatment of breast cancer patients. T cell receptor gene transfer can redirect the specificity of T cells. Chimeric receptor, scFv(anti-HER-2/neu)/zeta receptor, was successfully used to redirect cytotoxic T lymphocyte hybridoma cells to obtain anti-HER-2/neu positive tumor cells, suggesting the feasibility of treatment of breast cancer patients with T cell receptor gene transfer immunotherapy. Clinical trials will approve that immunotherapy is an effective method to cure breast cancer disease in the near future. Cellular & Molecular Immunology.

  8. Diameter of the thoracic and abdominal aorta in healthy Japanese

    International Nuclear Information System (INIS)

    Matsunaga, Wakako

    1989-01-01

    In 300 cases, diameter of thoracic and abdominal aorta in healthy Japanese is measured by computed tomography (CT) and the values are analyzed in relation to the age, sex and the level of the aorta on CT scan. Aorta becomes dilated with age. In female diameter of the aorta is correlated with age, on the other hand, diameter of those is not correlated with age in male. Diameter in male is larger than in female. Aorta tapers off and the ratio of tapering of the thoracic aorta is more prominent than that of the abdominal aorta. Therefore the calculations of the landmarks of tapering of the aorta and the ratio of diameter of the aorta to transverse diameter of the vertebral body at the levels of 10th thoracic and 3rd lumber vertebrae on CT scan are useful for judgement of normal range of diameter of the aorta. Calcifications of the wall of the aorta are seen initially at the age of 5th decade in the abdominal aorta and 6th decade in the thoracic aorta in healthy Japanese. They are noted in almost of the persons after the age of seventy years old. The presence of calcification is not correlated with diameter of the aorta at the same level on CT scan. (author)

  9. Small Diameter Bomb Increment II (SDB II)

    Science.gov (United States)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-439 Small Diameter Bomb Increment II (SDB II) As of FY 2017 President’s Budget Defense... Bomb Increment II (SDB II) DoD Component Air Force Joint Participants Department of the Navy Responsible Office References SAR Baseline (Production...Mission and Description Small Diameter Bomb Increment II (SDB II) is a joint interest United States Air Force (USAF) and Department of the Navy

  10. Breast conservation therapy for breast cancer. Radiation oncologist's point of view

    International Nuclear Information System (INIS)

    Hiraoka, Masahiro; Mitsumori, Michihide; Kokubo, Masaki; Fujishiro, Satsuki

    1998-01-01

    The roles and problems of radiation therapy in breast conserving therapy for breast cancer were presented. The roles of radiation therapy include decrease in breast recurrence, an alternative to axillary dissection for N0 cases, and neo-adjuvant radiation therapy. On the other hand, problems associated with radiation therapy are question of using radiation therapy for all cases, complications and worsening of cosmetics, and relatively high breast recurrence rates for margin-positive cases. The concept of breast conserving therapy is to improve QOL without decreasing treatment outcomes. It is considered that we should be more concentrated on the aspects of QOL because treatment outcomes of breast conserving therapy in Japan demonstrated sofar appear excellent. (author)

  11. Mammography in breast screening and in the evaluation and management of breast cancer

    International Nuclear Information System (INIS)

    Onyesoh, C.N.

    2006-01-01

    This paper aims to discuss the importance of breast screening most especially amongst women above the age of 40 years.the limitation of the screening procedure is due to lack of special machines and power awareness campaigns. the application of Mammography and ultrasound in the examination of the breast and other breast imaging techniques will be considered in this paper. The paper will look at the indications for mammography, indications for breast ultrasound, signs of breast carcinoma on mammography, breast enlargement and also the need for breast ultrasound in cases of discrete Mammography

  12. MRI-Guided Intervention for Breast Lesions Using the Freehand Technique in a 3.0-T Closed-Bore MRI Scanner: Feasibility and Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hye Young [Department of Radiology, Gyeongsang National University Hospital, Jinju 660-702 (Korea, Republic of); Kim, Sun Mi; Jang, Mijung; Yun, Bo La [Department of Radiology, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Kim, Sung-Won; Kang, Eunyoung [Department of Surgery, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Park, So Yeon [Department of Pathology, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Moon, Woo Kyung [Department of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul 110-744 (Korea, Republic of); Ko, Eun Sook [Department of Radiology, Samsung Medical Center, Seoul 135-710 (Korea, Republic of)

    2013-07-01

    To report the feasibility of magnetic resonance imaging (MRI)-guided intervention for diagnosing suspicious breast lesions detectable by MRI only, using the freehand technique with a 3.0-T closed-bore MRI scanner. Five women with 5 consecutive MRI-only breast lesions underwent MRI-guided intervention: 3 underwent MRI-guided needle localization and 2, MRI-guided vacuum-assisted biopsy. The interventions were performed in a 3.0-T closed-bore MRI system using a dedicated phased-array breast coil with the patients in the prone position; the freehand technique was used. Technical success and histopathologic outcome were analyzed. MRI showed that four lesions were masses (mean size, 11.5 mm; range, 7-18 mm); and 1, a nonmass-like enhancement (maximum diameter, 21 mm). The locations of the lesions with respect to the breast with index cancer were as follows: different quadrant, same breast - 3 cases; same quadrant, same breast - 1 case; and contralateral breast - 1 case. Histopathologic evaluation of the lesions treated with needle localization disclosed perilobular hemangioma, fibrocystic change, and fibroadenomatous change. The lesions treated with vacuum-assisted biopsy demonstrated a radial scar and atypical apocrine hyperplasia. Follow-up MRI after 2-7 months (mean, 4.6 months) confirmed complete lesion removal in all cases. MRI-guided intervention for breast lesions using the freehand technique with a 3.0-T closed-bore MRI scanner is feasible and accurate for diagnosing MRI-only lesions.

  13. MRI-Guided Intervention for Breast Lesions Using the Freehand Technique in a 3.0-T Closed-Bore MRI Scanner: Feasibility and Initial Results

    International Nuclear Information System (INIS)

    Choi, Hye Young; Kim, Sun Mi; Jang, Mijung; Yun, Bo La; Kim, Sung-Won; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Ko, Eun Sook

    2013-01-01

    To report the feasibility of magnetic resonance imaging (MRI)-guided intervention for diagnosing suspicious breast lesions detectable by MRI only, using the freehand technique with a 3.0-T closed-bore MRI scanner. Five women with 5 consecutive MRI-only breast lesions underwent MRI-guided intervention: 3 underwent MRI-guided needle localization and 2, MRI-guided vacuum-assisted biopsy. The interventions were performed in a 3.0-T closed-bore MRI system using a dedicated phased-array breast coil with the patients in the prone position; the freehand technique was used. Technical success and histopathologic outcome were analyzed. MRI showed that four lesions were masses (mean size, 11.5 mm; range, 7-18 mm); and 1, a nonmass-like enhancement (maximum diameter, 21 mm). The locations of the lesions with respect to the breast with index cancer were as follows: different quadrant, same breast - 3 cases; same quadrant, same breast - 1 case; and contralateral breast - 1 case. Histopathologic evaluation of the lesions treated with needle localization disclosed perilobular hemangioma, fibrocystic change, and fibroadenomatous change. The lesions treated with vacuum-assisted biopsy demonstrated a radial scar and atypical apocrine hyperplasia. Follow-up MRI after 2-7 months (mean, 4.6 months) confirmed complete lesion removal in all cases. MRI-guided intervention for breast lesions using the freehand technique with a 3.0-T closed-bore MRI scanner is feasible and accurate for diagnosing MRI-only lesions

  14. Risk Factors of Developing Long-Lasting Breast Pain After Breast Cancer Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lundstedt, Dan, E-mail: dan.lundstedt@vgregion.se [Division of Clinical Cancer Epidemiology, Department of Oncology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg (Sweden); Department of Oncology, Sahlgrenska University Hospital, Gothenburg (Sweden); Gustafsson, Magnus [Division of Clinical Cancer Epidemiology, Department of Oncology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg (Sweden); Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Gothenburg (Sweden); Steineck, Gunnar [Division of Clinical Cancer Epidemiology, Department of Oncology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg (Sweden); Division of Clinical Cancer Epidemiology, Department of Oncology-Pathology, the Karolinska Institute, Stockholm (Sweden); Malmstroem, Per [Skane Department of Oncology, Skane University Hospital, Lund (Sweden); Alsadius, David [Division of Clinical Cancer Epidemiology, Department of Oncology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg (Sweden); Department of Oncology, Sahlgrenska University Hospital, Gothenburg (Sweden); Sundberg, Agnetha [Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Gothenburg (Sweden); Wilderaeng, Ulrica [Division of Clinical Cancer Epidemiology, Department of Oncology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg (Sweden); Holmberg, Erik [Oncologic Centre, Sahlgrenska University Hospital, Gothenburg (Sweden); Johansson, Karl-Axel [Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Gothenburg (Sweden); Karlsson, Per [Department of Oncology, Sahlgrenska University Hospital, Gothenburg (Sweden)

    2012-05-01

    Purpose: Postoperative radiotherapy decreases breast cancer mortality. However, studies have revealed a long-lasting breast pain among some women after radiotherapy. The purpose of this study was to identify risk factors that contribute to breast pain after breast cancer radiotherapy. Methods and Materials: We identified 1,027 recurrence-free women in two cohorts of Swedish women treated for breast cancer. The women had breast-conserving surgery and postoperative radiotherapy, the breast was treated to 48 Gy in 2.4-Gy fractions or to 50 Gy in 2.0-Gy fractions. Young women received a boost of up to 16 Gy. Women with more than three lymph node metastases had locoregional radiotherapy. Systemic treatments were given according to health-care guidelines. Three to 17 years after radiotherapy, we collected data using a study-specific questionnaire. We investigated the relation between breast pain and potential risk modifiers: age at treatment, time since treatment, chemotherapy, photon energy, fractionation size, boost, loco-regional radiotherapy, axillary surgery, overweight, and smoking. Results: Eight hundred seventy-seven women (85%) returned the questionnaires. Among women up to 39 years of age at treatment, 23.1% had breast pain, compared with 8.7% among women older than 60 years (RR 2.66; 95% CI 1.33-5.36). Higher age at treatment (RR 0.96; 95% CI 0.94-0.98, annual decrease) and longer time since treatment (RR 0.93; 95% CI 0.88-0.98, annual decrease) were related to a lower occurrence of breast pain. Chemotherapy increased the occurrence of breast pain (RR 1.72; 95% CI 1.19-2.47). In the multivariable model only age and time since treatment were statistically significantly related to the occurrence of breast pain. We found no statistically significant relation between breast pain and the other potential risk modifiers. Conclusions: Younger women having undergone breast-conserving surgery with postoperative radiotherapy report a higher occurrence of long

  15. A prospective study of breast anthropomorphic measurements, volume and ptosis in 605 Asian patients with breast cancer or benign breast disease.

    Directory of Open Access Journals (Sweden)

    Nai-Si Huang

    Full Text Available The current study aims to summarize breast anthropomorphic measurement features in Chinese patients with breast diseases and to investigate their potential correlations with demographic factors.Fifteen breast anthropomorphic parameters of 605 Chinese female patients were collected prospectively. Breast ptosis status was scaled by two methods and breast volume was calculated according to a modified formula of BREAST-V.Among 1210 breasts, the average breast volume was 340.0±109.1 ml (91.8-919.2 ml. The distance from the nipple to the inframammary fold was 7.5±1.6 cm in the standing position. The width of the breast base was 14.3±1.4 cm (8.5-23.5 cm. The incidence of breast ptosis was 22.8% (274/1204, of which 37 (23.5% and 79 (31.7% women had severe ptosis assessed by different criteria. Increased height (OR[odds ratio] = 1.500, P<0.001, post-menopausal status (OR = 1.463, P = 0.02, increased BMI, breastfeeding for 7-12 months (OR = 1.882, P = 0.008 and more than one year (OR = 2.367, P = 0.001 were risk factors for an increased breast volume. Post-menopausal status (OR = 2.390, P<0.001 and OR = 2.621, P<0.001 for different scales, BMI≥24.7 kg/m2 (OR = 3.149, P<0.001 and OR = 2.495, P = 0.002, breastfeeding for 7-12 months (OR = 4.136, P = 0.004 and OR = 4.010, P = 0.002, and breastfeeding for more than one year (OR = 6.934, P<0.001 and OR = 6.707, P<0.001 were independent risk factors for breast ptosis.The current study provides anthropomorphic measurements data of Chinese women with breast diseases, which are useful for cosmetic and reconstructive breast surgery decisions. Post-menopausal status, increased BMI, and breastfeeding for more than six months were independent risk factors for both increased breast volume and breast ptosis.

  16. Diameter measurements of polystyrene particles with atomic force microscopy

    International Nuclear Information System (INIS)

    Garnaes, J

    2011-01-01

    The size of (nano) particles is a key parameter used in controlling their function. The particle size is also important in order to understand their physical and chemical properties and regulate their number in health and safety issues. In this work, the geometric diameters of polystyrene spheres of nominal diameter 100 nm are measured using atomic force microscopy. The measurements are based on the apex height and on the average distance between neighbouring spheres when they form a close-packed monolayer on a flat mica substrate. The most important influence parameters for the determination of the geometric diameter are the lateral air gaps and deformation of the spheres. The lateral air gaps are caused by significant size variations of the individual spheres, and a correction is calculated based on the simulation of packing of spheres. The deformation of the spheres is caused mainly by capillary forces acting when they are in contact with each other or with the mica substrate. Based on calculated capillary forces and the literature values of the elastic properties of the polystyrene and mica, the deformation is estimated to be 2 nm with a standard uncertainty of 2 nm. The geometric diameter of the polystyrene spheres was measured with a combined standard uncertainty of ≈3 nm. The measured vertical diameter of 92.3 nm and the certified mobility equivalent diameter measured by differential mobility analysis (DMA) are marginally consistent at a confidence level of 95%. However, the measured lateral geometric diameter was 98.9 nm and is in good agreement with DMA

  17. Breast cancer screening effect across breast density strata: A case-control study.

    Science.gov (United States)

    van der Waal, Daniëlle; Ripping, Theodora M; Verbeek, André L M; Broeders, Mireille J M

    2017-01-01

    Breast cancer screening is known to reduce breast cancer mortality. A high breast density may affect this reduction. We assessed the effect of screening on breast cancer mortality in women with dense and fatty breasts separately. Analyses were performed within the Nijmegen (Dutch) screening programme (1975-2008), which invites women (aged 50-74 years) biennially. Performance measures were determined. Furthermore, a case-control study was performed for women having dense and women having fatty breasts. Breast density was assessed visually with a dichotomized Wolfe scale. Breast density data were available for cases. The prevalence of dense breasts among controls was estimated with age-specific rates from the general population. Sensitivity analyses were performed on these estimates. Screening performance was better in the fatty than in the dense group (sensitivity 75.7% vs 57.8%). The mortality reduction appeared to be smaller for women with dense breasts, with an odds ratio (OR) of 0.87 (95% CI 0.52-1.45) in the dense and 0.59 (95% CI 0.44-0.79) in the fatty group. We can conclude that high density results in lower screening performance and appears to be associated with a smaller mortality reduction. Breast density is thus a likely candidate for risk-stratified screening. More research is needed on the association between density and screening harms. © 2016 UICC.

  18. 30 CFR 57.13021 - High-pressure hose connections.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-pressure hose connections. 57.13021... Air and Boilers § 57.13021 High-pressure hose connections. Except where automatic shutoff valves are...-pressure hose lines of 3/4-inch inside diameter or larger, and between high-pressure hose lines of 3/4-inch...

  19. Mammographic density and breast cancer risk in breast screening assessment cases and women with a family history of breast cancer.

    Science.gov (United States)

    Duffy, Stephen W; Morrish, Oliver W E; Allgood, Prue C; Black, Richard; Gillan, Maureen G C; Willsher, Paula; Cooke, Julie; Duncan, Karen A; Michell, Michael J; Dobson, Hilary M; Maroni, Roberta; Lim, Yit Y; Purushothaman, Hema N; Suaris, Tamara; Astley, Susan M; Young, Kenneth C; Tucker, Lorraine; Gilbert, Fiona J

    2018-01-01

    Mammographic density has been shown to be a strong independent predictor of breast cancer and a causative factor in reducing the sensitivity of mammography. There remain questions as to the use of mammographic density information in the context of screening and risk management, and of the association with cancer in populations known to be at increased risk of breast cancer. To assess the association of breast density with presence of cancer by measuring mammographic density visually as a percentage, and with two automated volumetric methods, Quantra™ and VolparaDensity™. The TOMosynthesis with digital MammographY (TOMMY) study of digital breast tomosynthesis in the Breast Screening Programme of the National Health Service (NHS) of the United Kingdom (UK) included 6020 breast screening assessment cases (of whom 1158 had breast cancer) and 1040 screened women with a family history of breast cancer (of whom two had breast cancer). We assessed the association of each measure with breast cancer risk in these populations at enhanced risk, using logistic regression adjusted for age and total breast volume as a surrogate for body mass index (BMI). All density measures showed a positive association with presence of cancer and all declined with age. The strongest effect was seen with Volpara absolute density, with a significant 3% (95% CI 1-5%) increase in risk per 10 cm 3 of dense tissue. The effect of Volpara volumetric density on risk was stronger for large and grade 3 tumours. Automated absolute breast density is a predictor of breast cancer risk in populations at enhanced risk due to either positive mammographic findings or family history. In the screening context, density could be a trigger for more intensive imaging. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. The impact of breast cancer biological subtyping on tumor size assessment by ultrasound and mammography - a retrospective multicenter cohort study of 6543 primary breast cancer patients

    International Nuclear Information System (INIS)

    Stein, Roland Gregor; Wollschläger, Daniel; Kreienberg, Rolf; Janni, Wolfgang; Wischnewsky, Manfred; Diessner, Joachim; Stüber, Tanja; Bartmann, Catharina; Krockenberger, Mathias; Wischhusen, Jörg; Wöckel, Achim; Blettner, Maria; Schwentner, Lukas

    2016-01-01

    Mammography and ultrasound are the gold standard imaging techniques for preoperative assessment and for monitoring the efficacy of neoadjuvant chemotherapy in breast cancer. Maximum accuracy in predicting pathological tumor size non-invasively is critical for individualized therapy and surgical planning. We therefore aimed to assess the accuracy of tumor size measurement by ultrasound and mammography in a multicentered health services research study. We retrospectively analyzed data from 6543 patients with unifocal, unilateral primary breast cancer. The maximum tumor diameter was measured by ultrasound and/or mammographic imaging. All measurements were compared to final tumor diameter determined by postoperative histopathological examination. We compared the precision of each imaging method across different patient subgroups as well as the method-specific accuracy in each patient subgroup. Overall, the correlation with histology was 0.61 for mammography and 0.60 for ultrasound. Both correlations were higher in pT2 cancers than in pT1 and pT3. Ultrasound as well as mammography revealed a significantly higher correlation with histology in invasive ductal compared to lobular cancers (p < 0.01). For invasive lobular cancers, the mammography showed better correlation with histology than ultrasound (p = 0.01), whereas there was no such advantage for invasive ductal cancers. Ultrasound was significantly superior for HR negative cancers (p < 0.001). HER2/neu positive cancers were also more precisely assessed by ultrasound (p < 0.001). The size of HER2/neu negative cancers could be more accurately predicted by mammography (p < 0.001). This multicentered health services research approach demonstrates that predicting tumor size by mammography and ultrasound provides accurate results. Biological tumor features do, however, affect the diagnostic precision