WorldWideScience

Sample records for imtek zeiss nanomagnetics

  1. Molecular nanomagnets

    CERN Document Server

    Gatteschi, Dante; Villain, Jacques

    2006-01-01

    Nanomagnetism is a rapidly expanding area of research which appears to be able to provide novel applications. Magnetic molecules are at the very bottom of the possible size of nanomagnets and they provide a unique opportunity to observe the coexistence of classical and quantum properties. The discovery in the early 90's that a cluster comprising twelve manganese ions shows hysteresis of molecular origin, and later proved evidence of quantum effects, opened a new research area whichis still flourishing through the collaboration of chemists and physicists. This book is the first attempt to cover

  2. Nanomagnetic Logic

    Science.gov (United States)

    Carlton, David Bryan

    The exponential improvements in speed, energy efficiency, and cost that the computer industry has relied on for growth during the last 50 years are in danger of ending within the decade. These improvements all have relied on scaling the size of the silicon-based transistor that is at the heart of every modern CPU down to smaller and smaller length scales. However, as the size of the transistor reaches scales that are measured in the number of atoms that make it up, it is clear that this scaling cannot continue forever. As a result of this, there has been a great deal of research effort directed at the search for the next device that will continue to power the growth of the computer industry. However, due to the billions of dollars of investment that conventional silicon transistors have received over the years, it is unlikely that a technology will emerge that will be able to beat it outright in every performance category. More likely, different devices will possess advantages over conventional transistors for certain applications and uses. One of these emerging computing platforms is nanomagnetic logic (NML). NML-based circuits process information by manipulating the magnetization states of single-domain nanomagnets coupled to their nearest neighbors through magnetic dipole interactions. The state variable is magnetization direction and computations can take place without passing an electric current. This makes them extremely attractive as a replacement for conventional transistor-based computing architectures for certain ultra-low power applications. In most work to date, nanomagnetic logic circuits have used an external magnetic clocking field to reset the system between computations. The clocking field is then subsequently removed very slowly relative to the magnetization dynamics, guiding the nanomagnetic logic circuit adiabatically into its magnetic ground state. In this dissertation, I will discuss the dynamics behind this process and show that it is greatly

  3. The Planetarium and the Carl Zeiss Corporation, 1923-1933

    Science.gov (United States)

    Boyce-Jacino, Katherine

    2018-01-01

    The Carl Zeiss Company of Jena, Germany, introduced the first prototype planetarium in the fall of 1923. By 1933, there were a dozen planetaria in Germany alone, and nearly a dozen more abroad. This talk argues that on one hand, Zeiss saw the planetarium as an opportunity to reintroduce German engineering to a skeptical international market. On the other, Zeiss recognized that a large part of the planetarium’s domestic appeal lay in the romance of its German origins. Through an examination of Zeiss’ corporate correspondence, propaganda, and contemporary international and domestic press, this talk argues that in advertising the planetarium in Germany and abroad, the Zeiss company relied on competing constructions of a post-war German identity rooted in conflicting understandings of space.

  4. Computational logic with square rings of nanomagnets

    Science.gov (United States)

    Arava, Hanu; Derlet, Peter M.; Vijayakumar, Jaianth; Cui, Jizhai; Bingham, Nicholas S.; Kleibert, Armin; Heyderman, Laura J.

    2018-06-01

    Nanomagnets are a promising low-power alternative to traditional computing. However, the successful implementation of nanomagnets in logic gates has been hindered so far by a lack of reliability. Here, we present a novel design with dipolar-coupled nanomagnets arranged on a square lattice to (i) support transfer of information and (ii) perform logic operations. We introduce a thermal protocol, using thermally active nanomagnets as a means to perform computation. Within this scheme, the nanomagnets are initialized by a global magnetic field and thermally relax on raising the temperature with a resistive heater. We demonstrate error-free transfer of information in chains of up to 19 square rings and we show a high level of reliability with successful gate operations of ∼94% across more than 2000 logic gates. Finally, we present a functionally complete prototype NAND/NOR logic gate that could be implemented for advanced logic operations. Here we support our experiments with simulations of the thermally averaged output and determine the optimal gate parameters. Our approach provides a new pathway to a long standing problem concerning reliability in the use of nanomagnets for computation.

  5. Integration of spintronic interface for nanomagnetic arrays

    Directory of Open Access Journals (Sweden)

    Andrew Lyle

    2011-12-01

    Full Text Available An experimental demonstration utilizing a spintronic input/output (I/O interface for arrays of closely spaced nanomagnets is presented. The free layers of magnetic tunnel junctions (MTJs form dipole coupled nanomagnet arrays which can be applied to different contexts including Magnetic Quantum Cellular Automata (MQCA for logic applications and self-biased devices for field sensing applications. Dipole coupled nanomagnet arrays demonstrate adaptability to a variety of contexts due to the ability for tuning of magnetic response. Spintronics allows individual nanomagnets to be manipulated with spin transfer torque and monitored with magnetoresistance. This facilitates measurement of the magnetic coupling which is important for (yet to be demonstrated data propagation reliability studies. In addition, the same magnetic coupling can be tuned to reduce coercivity for field sensing. Dipole coupled nanomagnet arrays have the potential to be thousands of times more energy efficient than CMOS technology for logic applications, and they also have the potential to form multi-axis field sensors.

  6. Study of switching behavior of exchange-coupled nanomagnets by transverse magnetization metrology

    Science.gov (United States)

    Dey, Himadri S.; Csaba, Gyorgy; Bernstein, Gary H.; Porod, Wolfgang

    2017-05-01

    We investigate the static switching modes of nanomagnets patterned from antiferromagnetically exchange-coupled magnetic multilayers, and compare them to nanomagnets having only dipole coupling between the ferromagnetic layers. Vibrating sample magnetometry experiments, supported by micromagnetic simulations, reveal two distinct switching mechanisms between the exchange-coupled and only dipole-coupled nanomagnets. The exchange-coupled nanomagnets exhibit gradual switching of the layers, dictated by the strong antiferromagnetic exchange coupling present between the layers. However, the layers of the only dipole-coupled nanomagnets show abrupt nucleation/growth type switching. A comprehensive understanding of the switching modes of such layered and patterned systems can add new insight into the reversal mechanisms of similar systems employed for spintronic and magneto-logic device applications.

  7. Zeiss ΣIGMA VP-FE-SEM User Guide

    Science.gov (United States)

    User guide for analyzing carbon based nanomaterials on a Zeiss Sigma microscope. The guide includes helpful steps for sample preparation and loading. Specific topics utilizing the scanning electron microscope are instrumentation startup and imagining. A variety of detectors in...

  8. Magnetization-induced dynamics of a Josephson junction coupled to a nanomagnet

    Science.gov (United States)

    Ghosh, Roopayan; Maiti, Moitri; Shukrinov, Yury M.; Sengupta, K.

    2017-11-01

    We study the superconducting current of a Josephson junction (JJ) coupled to an external nanomagnet driven by a time-dependent magnetic field both without and in the presence of an external ac drive. We provide an analytic, albeit perturbative, solution for the Landau-Lifshitz (LL) equations governing the coupled JJ-nanomagnet system in the presence of a magnetic field with arbitrary time dependence oriented along the easy axis of the nanomagnet's magnetization and in the limit of weak dimensionless coupling ɛ0 between the JJ and the nanomagnet. We show the existence of Shapiro-type steps in the I -V characteristics of the JJ subjected to a voltage bias for a constant or periodically varying magnetic field and explore the effect of rotation of the magnetic field and the presence of an external ac drive on these steps. We support our analytic results with exact numerical solution of the LL equations. We also extend our results to dissipative nanomagnets by providing a perturbative solution to the Landau-Lifshitz-Gilbert (LLG) equations for weak dissipation. We study the fate of magnetization-induced Shapiro steps in the presence of dissipation both from our analytical results and via numerical solution of the coupled LLG equations. We discuss experiments which can test our theory.

  9. 2D scattering of unpolarized beams of electrons by charged nanomagnets

    Energy Technology Data Exchange (ETDEWEB)

    Senbeta, Teshome, E-mail: teshearada@yahoo.com [Department of Physics, Addis Ababa University, P.O. Box 1176, Addis Ababa (Ethiopia); Mal' nev, V.N., E-mail: vnmalnev@aau.edu.et [Department of Physics, Addis Ababa University, P.O. Box 1176, Addis Ababa (Ethiopia)

    2012-07-15

    2D spin-dependent scattering of slow unpolarized beams of electrons by charged nanomagnets is analyzed in the Born approximation. The obtained scattering lengths are larger than those from the neutral nanomagnets approximately by one order. It is shown that for particular parameters of the system it is possible to polarize completely the scattered electrons in a narrow range of scattering angles. The most suitable system for realization of these effects is 2D Si electron gas with immersed nanomagnets. - Highlights: Black-Right-Pointing-Pointer We study 2D spin dependent electron scattering by charged nanomagnets. Black-Right-Pointing-Pointer The applicability of the Born approximation to the problem is discussed. Black-Right-Pointing-Pointer Unpolarized incident beams used to obtain completely polarized scattered electrons. Black-Right-Pointing-Pointer The study shows peculiarities of 2D spin dependent scattering enhanced by Coulomb potential. Black-Right-Pointing-Pointer The result obtained can be used as one method of controlling spin currents.

  10. The influence of shape anisotropy on vortex nucleation in Pacman-like nanomagnets

    International Nuclear Information System (INIS)

    Cambel, V.; Tóbik, J.; Šoltýs, J.; Fedor, J.; Precner, M.; Gaži, Š.; Karapetrov, G.

    2013-01-01

    In this paper we explore magnetic properties of Permalloy Pacman-like (PL) nanomagnets in external in-plain magnetic field. PL nanomagnets represent unique magnetic systems with broken symmetry, which are perspective as non-volatile memory elements. In these nanomagnets both bits, chirality and polarity of a single vortex state, can be easily read and written by in-plane magnetic field only. In the experimental part of this work we show that namely chirality of the∼1-μm large PL nanomagnet can be red easily by magnetic force microscopy method. The easy bit reading is enabled due to coupling of the polarity magnetization vector to the magnetic charges located at the surface of the PL missing sector. Using micromagnetic simulations we show the influence of spatial anisotropy on vortex nucleation and annihilation fields in the PL nanomagnets. Angular dependence of the vortex nucleation field is analysed in detail for PL nanomagnets of different diameter, thickness, and missing-sector dimensions. Best control of the ground state can be achieved for diameters not exceeding 100 nm, thicknesses from 40 to 45 nm, and for the missing sector angles from 30 to 60°. - Highlights: ► We explore magnetization dynamics in mesoscopic magnets with broken symmetry. ► We explain how to read and write chirality and polarity into such systems. ► Angular dependence of the vortex nucleation field in the systems is analysed

  11. Superradiance from crystals of molecular nanomagnets.

    Science.gov (United States)

    Chudnovsky, E M; Garanin, D A

    2002-10-07

    We show that crystals of molecular nanomagnets can exhibit giant magnetic relaxation due to the Dicke superradiance of electromagnetic waves. Rigorous theory is presented that combines superradiance with the Landau-Zener effect.

  12. Controlling the switching field in nanomagnets by means of domain-engineered antiferromagnets

    Science.gov (United States)

    Folven, E.; Linder, J.; Gomonay, O. V.; Scholl, A.; Doran, A.; Young, A. T.; Retterer, S. T.; Malik, V. K.; Tybell, T.; Takamura, Y.; Grepstad, J. K.

    2015-09-01

    Using soft x-ray spectromicroscopy, we investigate the magnetic domain structure in embedded nanomagnets defined in L a0.7S r0.3Mn O3 thin films and LaFe O3/L a0.7S r0.3Mn O3 bilayers. We find that shape-controlled antiferromagnetic domain states give rise to a significant reduction of the switching field of the rectangular nanomagnets. This is discussed within the framework of competition between an intrinsic spin-flop coupling and shape anisotropy. The data demonstrates that shape effects in antiferromagnets may be used to control the magnetic properties in nanomagnets.

  13. Nanomagnetism and spintronics

    CERN Document Server

    Shinjo, Teruya

    2014-01-01

    The concise and accessible chapters of Nanomagnetism and Spintronics, Second Edition, cover the most recent research in areas of spin-current generation, spin-calorimetric effect, voltage effects on magnetic properties, spin-injection phenomena, giant magnetoresistance (GMR), and tunnel magnetoresistance (TMR). Spintronics is a cutting-edge area in the field of magnetism that studies the interplay of magnetism and transport phenomena, demonstrating how electrons not only have charge but also spin. This second edition provides the background to understand this novel physical phenomeno

  14. Electric field control of magnetic states in isolated and dipole-coupled FeGa nanomagnets delineated on a PMN-PT substrate.

    Science.gov (United States)

    Ahmad, Hasnain; Atulasimha, Jayasimha; Bandyopadhyay, Supriyo

    2015-10-09

    We report observation of a 'non-volatile' converse magneto-electric effect in elliptical FeGa nanomagnets delineated on a piezoelectric PMN-PT substrate. The nanomagnets are first magnetized with a magnetic field directed along their nominal major axes. Subsequent application of a strong electric field across the piezoelectric substrate generates strain in the substrate, which is partially transferred to the nanomagnets and rotates the magnetizations of some of them away from their initial orientations. The rotated magnetizations remain in their new orientations after the field is removed, resulting in 'non-volatility'. In isolated nanomagnets, the magnetization rotates by <90° upon application of the electric field, but in a dipole-coupled pair consisting of one 'hard' and one 'soft' nanomagnet, which are both initially magnetized in the same direction by the magnetic field, the soft nanomagnet's magnetization rotates by [Formula: see text] upon application of the electric field because of the dipole influence of the hard nanomagnet. This effect can be utilized for a nanomagnetic NOT logic gate.

  15. 2D Spin-Dependent Diffraction of Electrons From Periodical Chains of Nanomagnets

    Directory of Open Access Journals (Sweden)

    Teshome Senbeta

    2012-03-01

    Full Text Available The scattering of the unpolarized beams of electrons by nanomagnets in the vicinity of some scattering angles leads to complete spin polarized electrons. This result is obtained with the help of the perturbation theory. The dipole-dipole interaction between the magnetic moment of the nanomagnet and the magnetic moment of electron is treated as perturbation. This interaction is not spherically symmetric. Rather it depends on the electron spin variables. It in turn results in spinor character of the scattering amplitudes. Due to the smallness of the magnetic interactions, the scattering length of this process is very small to be proved experimentally. To enhance the relevant scattering lengths, we considered the diffraction of unpolarized beams of electrons by linear chains of nanomagnets. By tuning the distance between the scatterers it is possible to obtain the diffraction maximum of the scattered electrons at scattering angles which corresponds to complete spin polarization of electrons. It is shown that the total differential scattering length is proportional to N2 (N is a number of scatterers. Even small number of nanomagnets in the chain helps to obtain experimentally visible enhancement of spin polarization of the scattered electrons.

  16. Voltage-controlled low-energy switching of nanomagnets through Ruderman-Kittel-Kasuya-Yosida interactions for magnetoelectric device applications

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Bahniman, E-mail: bghosh@utexas.edu; Dey, Rik; Register, Leonard F.; Banerjee, Sanjay K. [Microelectronics Research Center, University of Texas at Austin, 10100 Burnet Road, Bldg. 160, Austin, Texas 78758 (United States)

    2016-07-21

    In this article, we consider through simulation low-energy switching of nanomagnets via electrostatically gated inter-magnet Ruderman-Kittel-Kasuya-Yosida (RKKY) interactions on the surface of three-dimensional topological insulators, for possible memory and nonvolatile logic applications. We model the possibility and dynamics of RKKY-based switching of one nanomagnet by coupling to one or more nanomagnets of set orientation. Potential applications to both memory and nonvolatile logic are illustrated. Sub-attojoule switching energies, far below conventional spin transfer torque (STT)-based memories and even below CMOS logic appear possible. Switching times on the order of a few nanoseconds, comparable to times for STT switching, are estimated for ferromagnetic nanomagnets, but the approach also appears compatible with the use of antiferromagnets which may allow for faster switching.

  17. Voltage-controlled low-energy switching of nanomagnets through Ruderman-Kittel-Kasuya-Yosida interactions for magnetoelectric device applications

    International Nuclear Information System (INIS)

    Ghosh, Bahniman; Dey, Rik; Register, Leonard F.; Banerjee, Sanjay K.

    2016-01-01

    In this article, we consider through simulation low-energy switching of nanomagnets via electrostatically gated inter-magnet Ruderman-Kittel-Kasuya-Yosida (RKKY) interactions on the surface of three-dimensional topological insulators, for possible memory and nonvolatile logic applications. We model the possibility and dynamics of RKKY-based switching of one nanomagnet by coupling to one or more nanomagnets of set orientation. Potential applications to both memory and nonvolatile logic are illustrated. Sub-attojoule switching energies, far below conventional spin transfer torque (STT)-based memories and even below CMOS logic appear possible. Switching times on the order of a few nanoseconds, comparable to times for STT switching, are estimated for ferromagnetic nanomagnets, but the approach also appears compatible with the use of antiferromagnets which may allow for faster switching.

  18. Phonon superradiance and phonon laser effect in nanomagnets.

    Science.gov (United States)

    Chudnovsky, E M; Garanin, D A

    2004-12-17

    We show that the theory of spin-phonon processes in paramagnetic solids must take into account the coherent generation of phonons by the magnetic centers. This effect should drastically enhance spin-phonon rates in nanoscale paramagnets and in crystals of molecular nanomagnets.

  19. On the discrimination between nucleation and propagation in nanomagnetic logic devices

    Science.gov (United States)

    Ziemys, Grazvydas; Csaba, Gyorgy; Becherer, Markus

    2018-05-01

    In this paper we present the extensive nucleation and propagation characterization of fabricated nanomagnets by applying ns-range magnetic field pulses. For that, an artificial nucleation center (ANC) is created by focused ion beam irradiation (FIB) of a 50 x 50 nm area at the side of a Co/Pt island as typically used in Nanomagnetic Logic with perpendicular anisotropy (pNML). Laser-Kerr Microscope is applied for statistical evaluation of the switching probability of the whole magnet, while the wide-field-Kerr microscopy is employed to discriminate between the nucleation process (which takes place at the irradiated ANC area) and the domain wall propagation process along the magnet. We show that the nanomagnet can be treated as a single Stoner-Wolfhart particle above 100 ns field-pulse width, as the whole magnetization is switched during the field-pulse. By contrary, for field-pulse width below 100 ns, the domain wall (DW) motion is the limiting process hindering full magnetization reversal on that time-scale. However, the nucleation still follows the Arrhenius law. The results allow precise understanding of the reversal process and highlight the need for faster DW speed in pNML materials.

  20. On the discrimination between nucleation and propagation in nanomagnetic logic devices

    Directory of Open Access Journals (Sweden)

    Grazvydas Ziemys

    2018-05-01

    Full Text Available In this paper we present the extensive nucleation and propagation characterization of fabricated nanomagnets by applying ns-range magnetic field pulses. For that, an artificial nucleation center (ANC is created by focused ion beam irradiation (FIB of a 50 x 50 nm area at the side of a Co/Pt island as typically used in Nanomagnetic Logic with perpendicular anisotropy (pNML. Laser-Kerr Microscope is applied for statistical evaluation of the switching probability of the whole magnet, while the wide-field-Kerr microscopy is employed to discriminate between the nucleation process (which takes place at the irradiated ANC area and the domain wall propagation process along the magnet. We show that the nanomagnet can be treated as a single Stoner-Wolfhart particle above 100 ns field-pulse width, as the whole magnetization is switched during the field-pulse. By contrary, for field-pulse width below 100 ns, the domain wall (DW motion is the limiting process hindering full magnetization reversal on that time-scale. However, the nucleation still follows the Arrhenius law. The results allow precise understanding of the reversal process and highlight the need for faster DW speed in pNML materials.

  1. Dynamic separation of nanomagnet sublattices by orientation of elliptical elements

    Science.gov (United States)

    Yahagi, Y.; Berk, C. R.; Harteneck, B. D.; Cabrini, S. D.; Schmidt, H.

    2014-04-01

    We report the separation of the magnetization dynamics of densely packed nanomagnets depending on their orientation. The arrays consist of interleaved sublattices of identical nickel elliptical disks. By controlling the orientation of the elliptic disks relative to the external field in each sublattice, we simultaneously analyzed the magnetization dynamics in each sublattice using a time-resolved magnetooptic Kerr effect (TR-MOKE) microscopy system. The Fourier spectra showed clearly separated precession modes for sublattices with different orientations. The spectra were shown to be robust against the error in applied field orientation. The sublattice response can be tuned to a single collective frequency by choosing a symmetric field orientation. We analyzed the effect of the interelement coupling with various spacing between nanomagnets and found a relatively weak dependence on dipolar interactions in good agreement with micromagnetic simulations.

  2. Experiment-based thermal micromagnetic simulations of the magnetization reversal for ns-range clocked nanomagnetic logic

    Science.gov (United States)

    Ziemys, Grazvydas; Breitkreutz-v. Gamm, Stephan; Csaba, Gyorgy; Schmitt-Landsiedel, Doris; Becherer, Markus

    2017-05-01

    Extensive thermal micromagnetic simulations, based on experimental data and parameters, were performed to investigate the magnetization reversal in Co/Pt nanomagnets with locally reduced perpendicular anisotropy on the nanosecond range. The simulations were supported by experimental data gained on manufactured Co/Pt nanomagnets, as used in nanomagnetic logic. It is known that magnetization reversal is governed by two mechanisms. At pulse lengths longer than 100 ns, thermal activation dominates the magnetization reversal processes and follows the common accepted Arrhenius law. For pulse lengths shorter than 100 ns, the dynamic reversal dominates. With the help of thermal micro-magnetic simulations we found out that the point where the both mechanisms meet is determined by the damping constant α of the multilayer film stack. The optimization of ferromagnetic multilayer film stacks enables higher clocking rates with lower power consumption and, therefore, further improve the performance of pNML.

  3. Real time visualization of dynamic magnetic fields with a nanomagnetic ferrolens

    Science.gov (United States)

    Markoulakis, Emmanouil; Rigakis, Iraklis; Chatzakis, John; Konstantaras, Antonios; Antonidakis, Emmanuel

    2018-04-01

    Due to advancements in nanomagnetism and latest nanomagnetic materials and devices, a new potential field has been opened up for research and applications which was not possible before. We herein propose a new research field and application for nanomagnetism for the visualization of dynamic magnetic fields in real-time. In short, Nano Magnetic Vision. A new methodology, technique and apparatus were invented and prototyped in order to demonstrate and test this new application. As an application example the visualization of the dynamic magnetic field on a transmitting antenna was chosen. Never seen before high-resolution, photos and real-time color video revealing the actual dynamic magnetic field inside a transmitting radio antenna rod has been captured for the first time. The antenna rod is fed with six hundred volts, orthogonal pulses. This unipolar signal is in the very low frequency (i.e. VLF) range. The signal combined with an extremely short electrical length of the rod, ensures the generation of a relatively strong fluctuating magnetic field, analogue to the signal transmitted, along and inside the antenna. This field is induced into a ferrolens and becomes visible in real-time within the normal human eyes frequency spectrum. The name we have given to the new observation apparatus is, SPIONs Superparamagnetic Ferrolens Microscope (SSFM), a powerful passive scientific observation tool with many other potential applications in the near future.

  4. Non-monotonic probability of thermal reversal in thin-film biaxial nanomagnets with small energy barriers

    Directory of Open Access Journals (Sweden)

    N. Kani

    2017-05-01

    Full Text Available The goal of this paper is to investigate the short time-scale, thermally-induced probability of magnetization reversal for an biaxial nanomagnet that is characterized with a biaxial magnetic anisotropy. For the first time, we clearly show that for a given energy barrier of the nanomagnet, the magnetization reversal probability of an biaxial nanomagnet exhibits a non-monotonic dependence on its saturation magnetization. Specifically, there are two reasons for this non-monotonic behavior in rectangular thin-film nanomagnets that have a large perpendicular magnetic anisotropy. First, a large perpendicular anisotropy lowers the precessional period of the magnetization making it more likely to precess across the x^=0 plane if the magnetization energy exceeds the energy barrier. Second, the thermal-field torque at a particular energy increases as the magnitude of the perpendicular anisotropy increases during the magnetization precession. This non-monotonic behavior is most noticeable when analyzing the magnetization reversals on time-scales up to several tens of ns. In light of the several proposals of spintronic devices that require data retention on time-scales up to 10’s of ns, understanding the probability of magnetization reversal on the short time-scales is important. As such, the results presented in this paper will be helpful in quantifying the reliability and noise sensitivity of spintronic devices in which thermal noise is inevitably present.

  5. Current-induced magnetization dynamics in nanomagnets

    International Nuclear Information System (INIS)

    Bertotti, G.; Serpico, C.; Mayergoyz, I.D.; Bonin, R.; D'Aquino, M.

    2007-01-01

    An overview is given of the various approaches that have been proposed for the interpretation of spin-transfer-driven magnetization dynamics. Models of critical currents and critical fields for switching as well as for the onset of magnetization oscillations are discussed, together with methods for the construction of field-current stability diagrams. Finally, the role of thermal fluctuations is analyzed. Particular emphasis is given to the study of uniformly magnetized nanomagnets, which represents an essential step before moving to the numerical computation of more complex micromagnetic configurations

  6. Current-induced magnetization dynamics in nanomagnets

    Energy Technology Data Exchange (ETDEWEB)

    Bertotti, G. [INRIM-Istituto Nazionale di Ricerca Metrologica, Strada delle Cacce 91, 10135 Turin (Italy)]. E-mail: g.bertotti@inrim.it; Serpico, C. [Department of Electrical Engineering, Universita degli Studi Federico II, Via Claudio 21, 80125 Naples (Italy); Mayergoyz, I.D. [Department of Electrical and Computer Engineering, University of Maryland, College Park, MD 20742 (United States); Bonin, R. [INRIM-Istituto Nazionale di Ricerca Metrologica, Strada delle Cacce 91, 10135 Turin (Italy); D' Aquino, M. [Department of Electrical Engineering, Universita degli Studi Federico II, Via Claudio 21, 80125 Naples (Italy)

    2007-09-15

    An overview is given of the various approaches that have been proposed for the interpretation of spin-transfer-driven magnetization dynamics. Models of critical currents and critical fields for switching as well as for the onset of magnetization oscillations are discussed, together with methods for the construction of field-current stability diagrams. Finally, the role of thermal fluctuations is analyzed. Particular emphasis is given to the study of uniformly magnetized nanomagnets, which represents an essential step before moving to the numerical computation of more complex micromagnetic configurations.

  7. Single-Molecule Nanomagnets

    Science.gov (United States)

    Friedman, Jonathan R.; Sarachik, Myriam P.

    2010-04-01

    Single-molecule magnets straddle the classical and quantum mechanical worlds, displaying many fascinating phenomena. They may have important technological applications in information storage and quantum computation. We review the physical properties of two prototypical molecular nanomagnets, Mn12-acetate and Fe8: Each behaves as a rigid, spin-10 object and exhibits tunneling between up and down directions. As temperature is lowered, the spin-reversal process evolves from thermal activation to pure quantum tunneling. At low temperatures, magnetic avalanches occur in which the magnetization of an entire sample rapidly reverses. We discuss the important role that symmetry-breaking fields play in driving tunneling and in producing Berry-phase interference. Recent experimental advances indicate that quantum coherence can be maintained on timescales sufficient to allow a meaningful number of quantum computing operations to be performed. Efforts are under way to create monolayers and to address and manipulate individual molecules.

  8. Controlling the influence of elastic eigenmodes on nanomagnet dynamics through pattern geometry

    Energy Technology Data Exchange (ETDEWEB)

    Berk, C., E-mail: crberk@soe.ucsc.edu [School of Engineering, University of California Santa Cruz, 1156 High Street, Santa Cruz, CA 95064 (United States); Yahagi, Y. [School of Engineering, University of California Santa Cruz, 1156 High Street, Santa Cruz, CA 95064 (United States); Dhuey, S.; Cabrini, S. [Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Schmidt, H. [School of Engineering, University of California Santa Cruz, 1156 High Street, Santa Cruz, CA 95064 (United States)

    2017-03-15

    The effect of the nanoscale array geometry on the interaction between optically generated surface acoustic waves (SAWs) and nanomagnet dynamics is investigated using Time-Resolved Magneto-Optical Kerr Effect Microscopy (TR-MOKE). It is demonstrated that altering the nanomagnet geometry from a periodic to a randomized aperiodic pattern effectively removes the magneto-elastic effect of SAWs on the magnetization dynamics. The efficiency of this method depends on the extent of any residual spatial correlations and is quantified by spatial Fourier analysis of the two structures. Randomization allows observation and extraction of intrinsic magnetic parameters such as spin wave frequencies and damping to be resolvable using all-optical methods, enabling the conclusion that the fabrication process does not affect the damping.

  9. Controlling the influence of elastic eigenmodes on nanomagnet dynamics through pattern geometry

    Science.gov (United States)

    Berk, C.; Yahagi, Y.; Dhuey, S.; Cabrini, S.; Schmidt, H.

    2017-03-01

    The effect of the nanoscale array geometry on the interaction between optically generated surface acoustic waves (SAWs) and nanomagnet dynamics is investigated using Time-Resolved Magneto-Optical Kerr Effect Microscopy (TR-MOKE). It is demonstrated that altering the nanomagnet geometry from a periodic to a randomized aperiodic pattern effectively removes the magneto-elastic effect of SAWs on the magnetization dynamics. The efficiency of this method depends on the extent of any residual spatial correlations and is quantified by spatial Fourier analysis of the two structures. Randomization allows observation and extraction of intrinsic magnetic parameters such as spin wave frequencies and damping to be resolvable using all-optical methods, enabling the conclusion that the fabrication process does not affect the damping.

  10. Iron oxide-based nanomagnets in nanomedicine: fabrication and applications

    Directory of Open Access Journals (Sweden)

    Meng Meng Lin

    2010-02-01

    Full Text Available Iron oxide-based nanomagnets have attracted a great deal of attention in nanomedicine over the past decade. Down to the nanoscale, superparamagnetic iron oxide nanoparticles can only be magnetized in the presence of an external magnetic field, which makes them capable of forming stable colloids in a physio-biological medium. Their superparamagnetic property, together with other intrinsic properties, such as low cytotoxicity, colloidal stability, and bioactive molecule conjugation capability, makes such nanomagnets ideal in both in-vitro and in-vivo biomedical applications. In this review, a chemical, physical, and biological synthetic approach to prepare iron oxide-based nanomagnets with different physicochemical properties was illustrated and compared. The growing interest in iron oxide-based nanomagnets with multifunctionalities was explored in cancer diagnostics and treatment, focusing on their combined roles in a magnetic resonance contrast agent, hyperthermia, and magnetic force assisted drug delivery. Iron oxides as magnetic carriers in gene therapy were reviewed with a focus on the sophisticated design and construction of magnetic vectors. Finally, the iron oxide-based nanomagnet also represents a very promising tool in particle/cell interfacing in controlling cellular functionalities, such as adhesion, proliferation, differentiation, and cell patterning, in stem cell therapy and tissue engineering applications. Meng Meng Lin received a BSc in biotechnology at the University of Hong Kong, China in 2004 and an MSc in biomedical nanotechnology at Newcastle University, UK, in 2005. She is currently working toward her PhD at the Institute of Science and Technology in Medicine, Keele University, UK. She was a visiting student at the Royal Institute of Technology, Sweden, in 2006. Her research interests include nanoparticles preparation, cell/nanomaterials interface, and cancer-oriented drug delivery. Hyung-Hwan Kim received an MSc degree in

  11. Recent Trends in Spintronics-Based Nanomagnetic Logic

    Science.gov (United States)

    Das, Jayita; Alam, Syed M.; Bhanja, Sanjukta

    2014-09-01

    With the growing concerns of standby power in sub-100-nm CMOS technologies, alternative computing techniques and memory technologies are explored. Spin transfer torque magnetoresistive RAM (STT-MRAM) is one such nonvolatile memory relying on magnetic tunnel junctions (MTJs) to store information. It uses spin transfer torque to write information and magnetoresistance to read information. In 2012, Everspin Technologies, Inc. commercialized the first 64Mbit Spin Torque MRAM. On the computing end, nanomagnetic logic (NML) is a promising technique with zero leakage and high data retention. In 2000, Cowburn and Welland first demonstrated its potential in logic and information propagation through magnetostatic interaction in a chain of single domain circular nanomagnetic dots of Supermalloy (Ni80Fe14Mo5X1, X is other metals). In 2006, Imre et al. demonstrated wires and majority gates followed by coplanar cross wire systems demonstration in 2010 by Pulecio et al. Since 2004 researchers have also investigated the potential of MTJs in logic. More recently with dipolar coupling between MTJs demonstrated in 2012, logic-in-memory architecture with STT-MRAM have been investigated. The architecture borrows the computing concept from NML and read and write style from MRAM. The architecture can switch its operation between logic and memory modes with clock as classifier. Further through logic partitioning between MTJ and CMOS plane, a significant performance boost has been observed in basic computing blocks within the architecture. In this work, we have explored the developments in NML, in MTJs and more recent developments in hybrid MTJ/CMOS logic-in-memory architecture and its unique logic partitioning capability.

  12. Nanomagnets with high shape anisotropy and strong crystalline anisotropy: perspectives on magnetic force microscopy

    International Nuclear Information System (INIS)

    Campanella, H; Llobet, J; Esteve, J; Plaza, J A; Jaafar, M; Vázquez, M; Asenjo, A; Del Real, R P

    2011-01-01

    We report on a new approach for magnetic imaging, highly sensitive even in the presence of external, strong magnetic fields. Based on FIB-assisted fabricated high-aspect-ratio rare-earth nanomagnets, we produce groundbreaking magnetic force tips with hard magnetic character where we combine a high aspect ratio (shape anisotropy) together with strong crystalline anisotropy (rare-earth-based alloys). Rare-earth hard nanomagnets are then FIB-integrated to silicon microcantilevers as highly sharpened tips for high-field magnetic imaging applications. Force resolution and domain reversing and recovery capabilities are at least one order of magnitude better than for conventional magnetic tips. This work opens new, pioneering research fields on the surface magnetization process of nanostructures based either on relatively hard magnetic materials—used in magnetic storage media—or on materials like superparamagnetic particles, ferro/antiferromagnetic structures or paramagnetic materials.

  13. Superradiance From Molecular Nanomagnets

    Science.gov (United States)

    Chudnovsky, Eugene M.

    2003-03-01

    Magnetic dipolar transitions in individual magnetic molecules occur with a very low probability. However, typical wavelengths of the corresponding electromagnetic radiation are in the millimeter range, that is, comparable to the crystal size. This may result in the superradiance: The coherent emission of the electromagnetic radiation by the entire crystal, with the rate increased by the total number of molecules as compared to the rate of the individual emission. Rigorous theory of the superradiant resonant magnetic relaxation will be presented, that generalizes the Landau-Zener effect for the case of a macroscopic number of magnetic molecules coupled through the electromagnetic radiation [1]. Possible evidence of coherent electromagnetic effects in crystals of molecular nanomagnets placed inside a resonant cavity will be reported [2]. (This work has been supported by the NSF grant No. DMR-9978882.) [1] E. M. Chudnovsky and D. A. Garanin, Phys. Rev. Lett. 89, 157201 (7 Oct 2002). [2] J. Tejada, E. M. Chudnovsky, R. Amigo, and J. M. Hernandez, cond-mat/0210340 (16 Oct 2002).

  14. Nuclear Spin Nanomagnet in an Optically Excited Quantum Dot

    Science.gov (United States)

    Korenev, V. L.

    2007-12-01

    Linearly polarized light tuned slightly below the optical transition of the negatively charged exciton (trion) in a single quantum dot causes the spontaneous nuclear spin polarization (self-polarization) at a level close to 100%. The effective magnetic field of spin-polarized nuclei shifts the optical transition energy close to resonance with photon energy. The resonantly enhanced Overhauser effect sustains the stability of the nuclear self-polarization even in the absence of spin polarization of the quantum dot electron. As a result the optically selected single quantum dot represents a tiny magnet with the ferromagnetic ordering of nuclear spins—the nuclear spin nanomagnet.

  15. Molecular nanomagnets: Syntheses and characterization of high nuclearity transition metal complexes

    Science.gov (United States)

    Foguet-Albiol, Maria D.

    2006-12-01

    High nuclearity transition metal complexes have attracted a lot of attention because of their aesthetically pleasant structures and/or their potential applications. The fusion of the world of magnetism with the exciting research in physics and chemistry led to the realization of interesting types of materials that can function as nanoscale magnetic particles. The study of the magnetism of inorganic complexes and especially the study of these molecular nanomagnets (or single-molecule magnets, SMMs) is a field that has generated intense interest in the scientific community. Interest in these molecular nanomagnets arises as part of a broader investigation of nanomagnetism (and nanotechnology), as these represent the ultimate step in device miniaturization. The primary purpose of this dissertation is the development of new synthetic methods intended for the preparation of novel single-molecule magnets (SMMs). The definition of the "bottom-up approach" is to increase the size of molecules by adding new magnetic centers; this is attractive but does not actually reflect how the chemistry takes place. Various strategies have been employed in developing the aforementioned synthetic methods which include the use of mononuclear as well as preformed clusters as starting materials; and the introduction of new alcohol based ligands as N-methyldiethanolamine (mdaH2) and triethanolamine (teaH3), since currently only a few alcohol based ligands have been used by different research groups. Many of these efforts have led to the isolation of new polynuclear Mn clusters with nuclearities ranging all the way from four to thirty-one. Additionally, a family of related Fe7 complexes has been synthesized. The transition metal cluster chemistry has also been extended to nickel-containing species. Many of these polynulear transition metal complexes function as single-molecule magnets. An additional research direction discussed herein is the study of the exchange-coupled dimer of single

  16. EDITORIAL: Opposites attract: nanomagnetism in theory and practice Opposites attract: nanomagnetism in theory and practice

    Science.gov (United States)

    Demming, Anna

    2012-09-01

    Putting theory into practice in nanotechnology can be far from trivial. Magnetic artificial atoms have been an example of the gulf that can sometimes separate idea from experiment. The step from regular semiconductor artificial atoms to magnetic may not confound the imagination, but it poses no mean fabrication challenge to experimental physicists. In this issue researchers in Germany have successfully fabricated a magnetic artificial atom [1]. As the researchers point out, the systems look promising for further study of the transport properties of 0D magnetic objects. Magnetic behavior in nanoscale systems has inspired a number of technological developments, such as energetically efficient digital logic circuitry [2]. Theory dictates that less energy is dissipated in the manipulation of nanomagnet logic bits than in the manipulation of electrical charges in transistor switches. Among the challenges when putting this into practice is the issue of sequential clocking. The nanomagnets' polarizations need to be rotated through 90° from the easy to the hard axis ready to be set before propagating the logic bits from one stage to the next. Ideally this would be a localized process to allow the efficiencies of a pipe-line computer architecture. Researchers at Virginia Commonwealth University in the US showed that a small voltage applied to a multiferroic nanomagnet can cause this polarization rotation [3]. They further showed that the switching delay of this process is not impracticably long, suggesting that the process is promising for logic circuits that are very fast as well as energy efficient [4]. Researchers in Germany have demonstrated magnetic force microscopy for high resolution imaging using a carbon nanotube filled with iron [5]. A magnetic dipole moment in the iron extends from end to end of the iron nanowire in the carbon nanotube. As a result of the extreme aspect ratio of the nanowire only the pole at one end is involved in the imaging process. The

  17. Leveraging the Radiation-Resistance and Power Efficiency of Nano-Magnetic Logic to Develop More Affordable, Efficient, and Reliable Space Technologies

    Data.gov (United States)

    National Aeronautics and Space Administration — I am researching nano-magnetic logic (NML) because it has low power consumption, high density of computing and memory elements, CMOS integration capabilities, and...

  18. Exploring the no-man's land between molecular nanomagnets and magnetic nanoparticles.

    Science.gov (United States)

    Gatteschi, Dante; Fittipaldi, Maria; Sangregorio, Claudio; Sorace, Lorenzo

    2012-05-14

    The comparison of the structural and magnetic properties of molecular nanomagnets (MNM) and magnetic nanoparticles (MNP) can be instructive to get a deeper understanding of the magnetic behavior on the intermediate scale between molecular and bulk objects. In this respect iron oxo based clusters are particularly interesting, since they provide an increasing number of molecular systems with sizes close to that of iron oxide MNP. In this Minireview we report a survey of literature data aimed at improving our understanding of the emergence of MNP properties from MNM ones. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Evaluation of the magnetic field requirements for nanomagnetic gene transfection

    Science.gov (United States)

    Fouriki, A.; Farrow, N.; Clements, M.A.; Dobson, J.

    2010-01-01

    The objective of this work was to examine the effects of magnet distance (and by proxy, field strength) on nanomagnetic transfection efficiency. Methods non-viral magnetic nanoparticle-based transfection was evaluated using both static and oscillating magnet arrays. Results Fluorescence intensity (firefly luciferase) of transfected H292 cells showed no increase using a 96-well NdFeB magnet array when the magnets were 5 mm from the cell culture plate or nearer. At 6 mm and higher, fluorescence intensity decreased systematically. Conclusion In all cases, fluorescence intensity was higher when using an oscillating array compared to a static array. For distances closer than 5 mm, the oscillating system also outperformed Lipofectamine 2000™. PMID:22110859

  20. Evaluation of the magnetic field requirements for nanomagnetic gene transfection

    Directory of Open Access Journals (Sweden)

    A. Fouriki

    2010-07-01

    Full Text Available The objective of this work was to examine the effects of magnet distance (and by proxy, field strength on nanomagnetic transfection efficiency. Methods: non-viral magnetic nanoparticle-based transfection was evaluated using both static and oscillating magnet arrays. Results: Fluorescence intensity (firefly luciferase of transfected H292 cells showed no increase using a 96-well NdFeB magnet array when the magnets were 5 mm from the cell culture plate or nearer. At 6 mm and higher, fluorescence intensity decreased systematically. Conclusion: In all cases, fluorescence intensity was higher when using an oscillating array compared to a static array. For distances closer than 5 mm, the oscillating system also outperformed Lipofectamine 2000™.

  1. Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster.

    Science.gov (United States)

    Olsen, Thomas

    2007-02-01

    This study aimed to demonstrate how the level of accuracy in intraocular lens (IOL) power calculation can be improved with optical biometry using partial optical coherence interferometry (PCI) (Zeiss IOLMaster) and current anterior chamber depth (ACD) prediction algorithms. Intraocular lens power in 461 consecutive cataract operations was calculated using both PCI and ultrasound and the accuracy of the results of each technique were compared. To illustrate the importance of ACD prediction per se, predictions were calculated using both a recently published 5-variable method and the Haigis 2-variable method and the results compared. All calculations were optimized in retrospect to account for systematic errors, including IOL constants and other off-set errors. The average absolute IOL prediction error (observed minus expected refraction) was 0.65 dioptres with ultrasound and 0.43 D with PCI using the 5-variable ACD prediction method (p ultrasound, respectively (p power calculation can be significantly improved using calibrated axial length readings obtained with PCI and modern IOL power calculation formulas incorporating the latest generation ACD prediction algorithms.

  2. Quantum Effects in Molecule-Based Nanomagnets

    Science.gov (United States)

    Hill, Stephen

    2005-11-01

    Research into molecule-based-magnets has made immense strides in recent years, with the discoveries of all organic molecular magnets, room temperature 3D ordered permanent magnets, and single-molecule magnets (SMMs), the latter exhibiting a host of spectacular quantum phenomena; for a review, see ref. [1]. SMMs represent a molecular approach to nanoscale and sub-nanoscale magnetic particles. They offer all of the advantages of molecular chemistry as well as displaying the superparamagnetic properties of mesoscale magnetic particles of much larger dimensions. They also straddle the interface between classical and quantum behavior; for example, they exhibit quantum tunneling of their magnetization. I will give a general introduction to this area of research, followed by an overview of recent results obtained using high-frequency (40-800 GHz) electron paramagnetic resonance techniques developed at the University of Florida. These results include: an elucidation of the role of molecular symmetry in the magnetic quantum tunneling phenomenon [2]; and the observation of quantum entanglement between pairs of nanomagnets within a supramolecular dimer [3]. 1. D. Gatteschi and R. Sessoli, Angew. Chem. 42, 268 (2003). 2. E. del Barco et al., J. Low Temp. Phys. 140, 119-174 (2005). 3. S. Hill et al., Science 302, 1015 (2003).

  3. Nano-magnetic particles used in biomedicine: core and coating materials.

    Science.gov (United States)

    Karimi, Z; Karimi, L; Shokrollahi, H

    2013-07-01

    Magnetic nanoparticles for medical applications have been developed by many researchers. Separation, immunoassay, drug delivery, magnetic resonance imaging and hyperthermia are enhanced by the use of suitable magnetic nanoparticles and coating materials in the form of ferrofluids. Due to their low biocompatibility and low dispersion in water solutions, nanoparticles that are used for biomedical applications require surface treatment. Various kinds of coating materials including organic materials (polymers), inorganic metals (gold, platinum) or metal oxides (aluminum oxide, cobalt oxide) have been attracted during the last few years. Based on the recent advances and the importance of nanomedicine in human life, this paper attempts to give a brief summary on the different ferrite nano-magnetic particles and coatings used in nanomedicine. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Vortical structures for nanomagnetic memory induced by dipole-dipole interaction in monolayer disks

    Science.gov (United States)

    Liu, Zhaosen; Ciftja, Orion; Zhang, Xichao; Zhou, Yan; Ian, Hou

    2018-05-01

    It is well known that magnetic domains in nanodisks can be used as storage units for computer memory. Using two quantum simulation approaches, we show here that spin vortices on magnetic monolayer nanodisks, which are chirality-free, can be induced by dipole-dipole interaction (DDI) on the disk-plane. When DDI is sufficiently strong, vortical and anti-vortical multi-domain textures can be generated simultaneously. Especially, a spin vortex can be easily created and deleted through either external magnetic or electrical signals, making them ideal to be used in nanomagnetic memory and logical devices. We demonstrate these properties in our simulations.

  5. Field-dependent spin chirality and frustration in V3 and Cu3 nanomagnets in transverse magnetic field. 2. Spin configurations, chirality and intermediate spin magnetization in distorted trimers

    International Nuclear Information System (INIS)

    Belinsky, Moisey I.

    2014-01-01

    Highlights: • Distorted spin configurations determine field behavior of the variable chiralities. • Distortions change spin chiralities, intermediate M 12 ± and staggered magnetization. • Magnetizations, distorted vector and scalar chiralities are strongly correlated. • Distorted V 3 , Cu 3 nanomagnets possess large vector chirality in the ground state in B ⊥ . • Chiralities and distortions in EPR, INS and NMR spectra were considered. - Abstract: Correlated spin configurations, magnetizations, frustration, vector κ ¯ z and scalar χ ¯ chiralities are considered for distorted V ‾ 3 , /Cu 3 / anisotropic DM nanomagnets in transverse B x ‖X and longitudinal B‖Z fields. Different planar configurations in the ground and excited states of distorted nanomagnets in B x determine different field behavior of the vector chiralities and the degenerate frustration in these states correlated with the M ~ 12 ± (B x ) intermediate spin (IS) magnetization which describes the S 12 characteristics, χ=0. Distortion results in the reduced κ ¯ z <1 chirality in the ground distorted configuration and in the maximum κ z =±1 in the excited states with the planar 120° configurations at avoided level crossing. In B‖Z, distorted longitudinal spin-collinear configurations are characterized by the reduced degenerate frustration, out-of-plane staggered and IS M ~ 12 ± (B z ) magnetizations, and in-plane toroidal moments, correlated with the κ ¯ z , χ ¯ chiralities, χ ¯ =±|κ ¯ z |. The chiralities and IS magnetization in EPR, INS and NMR spectra are considered. The quantitative correlations describe variable spin chirality, frustration and field manipulation of chiralities in nanomagnets

  6. Magnetization Switching of a Co /Pt Multilayered Perpendicular Nanomagnet Assisted by a Microwave Field with Time-Varying Frequency

    Science.gov (United States)

    Suto, Hirofumi; Kanao, Taro; Nagasawa, Tazumi; Mizushima, Koichi; Sato, Rie

    2018-05-01

    Microwave-assisted magnetization switching (MAS) is attracting attention as a method for reversing nanomagnets with a high magnetic anisotropy by using a small-amplitude magnetic field. We experimentally study MAS of a perpendicularly magnetized nanomagnet by applying a microwave magnetic field with a time-varying frequency. Because the microwave field frequency can follow the nonlinear decrease of the resonance frequency, larger magnetization excitation than that in a constant-frequency microwave field is induced, which enhances the MAS effect. The switching field decreases almost linearly as the start value of the time-varying microwave field frequency increases, and it becomes smaller than the minimum switching field in a constant-frequency microwave field. To obtain this enhancement of the MAS effect, the end value of the time-varying microwave field frequency needs to be almost the same as or lower than the critical frequency for MAS in a constant-frequency microwave field. In addition, the frequency change typically needs to take 1 ns or longer to make the rate of change slow enough for the magnetization to follow the frequency change. This switching behavior is qualitatively explained by the theory based on the macrospin model.

  7. Adaptive silicone-membrane lenses: planar vs. shaped membrane

    CSIR Research Space (South Africa)

    Schneider, F

    2009-08-01

    Full Text Available Engineering, Georges-Koehler-Allee 102, Freiburg 79110, Germany florian.schneider@imtek.uni-freiburg.de ABSTRACT We compare the performance and optical quality of two types of adaptive fluidic silicone-membrane lenses. The membranes feature either a...-membrane lenses: planar vs. shaped membrane Florian Schneider1,2, Philipp Waibel2 and Ulrike Wallrabe2 1 CSIR, Materials Science and Manufacturing, PO Box 395, Pretoria 0001, South Africa 2 University of Freiburg – IMTEK, Department of Microsystems...

  8. Comparing the Zeiss Callisto Eye and the Alcon Verion Image Guided System Toric Lens Alignment Technologies.

    Science.gov (United States)

    Hura, Arjan S; Osher, Robert H

    2017-07-01

    To compare the alignment meridian generated by the Zeiss Callisto Eye (Carl Zeiss AG, Dublin, CA) and the Alcon Verion Image Guided System (Alcon Laboratories, Inc., Fort Worth, TX). In this retrospective comparative evaluation of technology, intraoperative images were captured at different steps in the same surgery, allowing the comparison of the guidance lines generated by the Verion system to the parallel guidance lines generated by the Callisto Eye system. Measurements of each hemi-meridian were quantified using Adobe Photoshop 2015 CC software (Adobe Systems, San Jose, CA). The numbers of degrees separating these alignment meridians were calculated, entered into a database, and analyzed. The authors found that of 98 captured images of 16 eyes, the two technologies were identical in 0 eyes (θ 1 = θ 2 = 0), similar by 3° in 52 (53%) captured images (θ 1 ≠ θ 2 ≠ 0), and different by at least 3° in 46 (47%) captured images (θ 1 ≠ θ 2 ≠ 0). The target meridians were superimposed, the target lines were minimally separated, and the target lines were dissimilar. It was noted that some intraoperative variation occurred from measurement to measurement. Within the small group of 16 cases of routine toric lens implantation in this study, the absolute average number of degrees of misalignment between the Verion and Callisto Eye systems was 3.355 for θ 1 and 3.838 for θ 2 . On average, the intraoperative variation termed "drift" was noted to be 3.963° for θ 1 , and 4.557° for θ 2 . The authors found that small deviations were frequent when comparing two sophisticated technologies. Although deviations greater than 3° occurred in less than 47% of captured images from 16 eyes, smaller but significant variations of less than 3° occurred in 53% of captured images from 16 eyes. It was rare to identify a large deviation. However, the authors identified "drift" in the same eye when measurements were taken at different times. The results indicate that the two

  9. Facile synthesis of a boronate affinity sorbent from mesoporous nanomagnetic polyhedral oligomeric silsesquioxanes composite and its application for enrichment of catecholamines in human urine

    Energy Technology Data Exchange (ETDEWEB)

    He, Haibo, E-mail: hbhe2006@shu.edu.cn [Department of Chemistry, Shanghai University, Shanghai 200444 (China); Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072 (China); Zhou, Ziqing; Dong, Chen; Wang, Xin [Department of Chemistry, Shanghai University, Shanghai 200444 (China); Yu, Qiong-wei [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072 (China); Lei, Yunyi; Luo, Liqiang [Department of Chemistry, Shanghai University, Shanghai 200444 (China); Feng, Yuqi [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072 (China)

    2016-11-09

    A boronate-decorated nanomagnetic organic-inorganic hybrid material was facilely synthesized by utilizing the nanomagnetic polyhedral oligomeric silsesquioxanes (POSS) composite (Fe{sub 3}O{sub 4}@POSS) as the base platform. A simple copolymerization occurred between 3-acrylamidophenylboronic acid (AAPBA) and the residual end vinyl groups supplied by the substrate. Here the special emphasis was placed on the octavinyl POSS, which not only acted as the building blocks for a hybrid architecture but also facilitated the process of grafting boronate groups onto the surface of POSS based nanomagnetic composite (Fe{sub 3}O{sub 4}@POSS). The successful immobilization of affinity ligand-AAPBA on the Fe{sub 3}O{sub 4}@POSS was confirmed by Fourier transform infrared (FT-IR), elemental analysis, inductively coupled plasma atomic emission spectrometer (ICP-AES), field emission scanning electron microscope. A magnetic solid-phase extraction (MSPE) for cis-diols enrichment was developed using the as-prepared Fe{sub 3}O{sub 4}@POSS-AAPBA material as an affinity sorbent and three catecholamines (CAs), namely noradrenaline, epinephrine and isoprenaline, as model analytes. Under the optimal extraction conditions, sensitive and simultaneous analysis of three CAs from the urine sample was achieved by high-performance liquid chromatography with UV detection (HPLC-UV). The limits of detection (LOD, S/N = 3) and the limits of quantitation (LOQ, S/N = 10) for the target analytes were 0.81–1.32 ng mL{sup −1} and 2.70–4.40 ng mL{sup −1}, respectively. Also good recoveries (85.5–101.7%) and repeatability (RSD≤10.1%) were obtained by this method. This work not only showed a facility for the utilization of Fe{sub 3}O{sub 4}@POSS as a substrate for constructing a boronate functionalized nanomagnetic sorbent, but also demonstrated the capability of the derived material for recognition of trace amount of cis-diols biomolecules presented in complicated biological matrices

  10. Nanomagnetic domains of chromium deposited on vertically-aligned carbon nanotubes

    International Nuclear Information System (INIS)

    Wright, Andrew C.; Faulkner, Michael K.; Harris, Robert C.; Goddard, Alex; Abbott, Andrew P.

    2012-01-01

    The drive to create ever smaller magnetic memory devices has led to the development of new nanomagnetic domains on surfaces. This paper reports the development of nano-chromium magnetic domains obtained using electrodeposition on vertically aligned carbon nanofibers arrays. Attempts to achieve this using conventional aqueous solutions were unsuccessful even after thin nickel underlayers were applied. The use of a novel electrolyte, a deep eutectic solvent, made from choline chloride: chromium (III) chloride enabled highly conformal overcoatings of chromium on individual bare carbon nanotubes to be obtained. Very high aspect ratio metal microstructures could be obtained by this novel technology. Magnetic imaging of the coated nanoarrays showed there to be clear magnetic character to the coating when the thin coatings were applied but this disappeared when the deposits were thicker and more contiguous. - Highlights: ► Nanoscale chromium deposited from non-aqueous electrolyte shows magnetic behavior. ► Vertically aligned carbon nanotubes conformally coated with chromium metal. ► Ionic liquid electrolyte superior to chromic acid for plating high aspect ratio structures.

  11. Nanomagnetic domains of chromium deposited on vertically-aligned carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Andrew C., E-mail: a.wright@glyndwr.ac.uk [Advanced Materials Research Laboratory, Materials Science Research Center, Glyndwr University, Wrexham LL11 2AW (United Kingdom); Faulkner, Michael K., E-mail: m.faulkner@manchester.ac.uk [Manchester Materials Science Centre, University of Manchester, Grosvenor Street, Manchester M13 9PL (United Kingdom); Harris, Robert C.; Goddard, Alex; Abbott, Andrew P., E-mail: apa1@le.ac.uk [Department of Chemistry, University of Leicester, Leicester LE1 7RH (United Kingdom)

    2012-12-15

    The drive to create ever smaller magnetic memory devices has led to the development of new nanomagnetic domains on surfaces. This paper reports the development of nano-chromium magnetic domains obtained using electrodeposition on vertically aligned carbon nanofibers arrays. Attempts to achieve this using conventional aqueous solutions were unsuccessful even after thin nickel underlayers were applied. The use of a novel electrolyte, a deep eutectic solvent, made from choline chloride: chromium (III) chloride enabled highly conformal overcoatings of chromium on individual bare carbon nanotubes to be obtained. Very high aspect ratio metal microstructures could be obtained by this novel technology. Magnetic imaging of the coated nanoarrays showed there to be clear magnetic character to the coating when the thin coatings were applied but this disappeared when the deposits were thicker and more contiguous. - Highlights: Black-Right-Pointing-Pointer Nanoscale chromium deposited from non-aqueous electrolyte shows magnetic behavior. Black-Right-Pointing-Pointer Vertically aligned carbon nanotubes conformally coated with chromium metal. Black-Right-Pointing-Pointer Ionic liquid electrolyte superior to chromic acid for plating high aspect ratio structures.

  12. Molecular nanomagnets and magnetic nanoparticles: the EMR contribution to a common approach.

    Science.gov (United States)

    Fittipaldi, M; Sorace, L; Barra, A-L; Sangregorio, C; Sessoli, R; Gatteschi, D

    2009-08-21

    The current status and future developments of the use of electron magnetic resonance (EMR) for the investigation of magnetic nano-systems is here reviewed. The aim is to stimulate efforts to provide a unified view of the properties of magnetic nanoparticles (MNP) comprising a few hundred magnetic centres, and molecular nanomagnets which contain up to ca. one hundred magnetic centres (MNM). The size of the systems is becoming the same but the approaches to the interpretation of their properties are still different, being bottom up for the latter and top down for the former. We make the point here of the need for a common viewpoint, highlighting the status of the two fields and giving some hints for the future developments. EMR has been a powerful tool for the investigation of magnetic nano-objects and it can provide a tool of fundamental importance for the development of a unified view.

  13. Micromagnetic simulation of energy consumption and excited eigenmodes in elliptical nanomagnetic switches

    International Nuclear Information System (INIS)

    Carlotti, G.; Madami, M.; Gubbiotti, G.; Tacchi, S.

    2014-01-01

    Sub-200 nm patterned magnetic dots are key elements for the design of magnetic switches, memory cells or elementary units of nanomagnetic logic circuits. In this paper, we analyse by micromagnetic simulations the magnetization reversal, the dissipated energy and the excited spin eigenmodes in bistable magnetic switches, consisting of elliptical nanodots with 100×60 nm lateral dimensions. Two different strategies for reversal are considered and the relative results compared: (i) the irreversible switching obtained by the application of an external field along the easy axis, in the direction opposite to the initial magnetization; (ii) the precessional switching accomplished by the application of a short magnetic field pulse, oriented perpendicular to the initial magnetization direction. The obtained results are discussed in terms of deviation from the macrospin behavior, energy dissipation and characteristics of the spectrum of spin eigenmodes excited during the magnetization reversal process

  14. Adaptation and performance of the Cartesian coordinates fast multipole method for nanomagnetic simulations

    International Nuclear Information System (INIS)

    Zhang Wen; Haas, Stephan

    2009-01-01

    An implementation of the fast multiple method (FMM) is performed for magnetic systems with long-ranged dipolar interactions. Expansion in spherical harmonics of the original FMM is replaced by expansion of polynomials in Cartesian coordinates, which is considerably simpler. Under open boundary conditions, an expression for multipole moments of point dipoles in a cell is derived. These make the program appropriate for nanomagnetic simulations, including magnetic nanoparticles and ferrofluids. The performance is optimized in terms of cell size and parameter set (expansion order and opening angle) and the trade off between computing time and accuracy is quantitatively studied. A rule of thumb is proposed to decide the appropriate average number of dipoles in the smallest cells, and an optimal choice of parameter set is suggested. Finally, the superiority of Cartesian coordinate FMM is demonstrated by comparison to spherical harmonics FMM and FFT.

  15. Reproducibility of disc and macula optical coherence tomography using the Canon OCT-HS100 as compared with the Zeiss Cirrus HD-OCT.

    Science.gov (United States)

    Brautaset, Rune; Birkeldh, Ulrika; Rosén, Rebecka; Ramsay, Marika Wahlberg; Nilsson, Maria

    2014-01-01

    In a clinical setting, the usefulness of optical coherence tomography (OCT) is strongly dependent on reproducibility of the measurement. The aim of the present study was to evaluate macula and optic disc measurement reproducibility with the new spectral-domain OCT (SD-OCT) from Canon (Canon OCT-HS100) and to compare reproducibility and obtained measurements with the Zeiss Cirrus HD-OCT. Macula and optic disc parameters from the right eyes of 31 subjects were obtained twice with both instruments. Interoperator reproducibility was evaluated by use of the coefficient of repeatability (CR), and the obtained measurements were compared between the instruments. No difference in interoperator reproducibility could be found when comparing the 2 instruments and reproducibility ranged from 3.94% to 12.77% for optic disc parameters and from 1.19% to 3.54% for macula parameters. The lowest reproducibility was found for cup volume and vertical cup/disc ratio with both instruments. For all macula and retinal nerve fiber layer (RNFL) thickness measurements, there was a statistical difference when comparing the 2 instruments, except for RFNL measurements of the superior quadrant, with the Canon OCT-HS100 always evaluating the thickness to be thicker; however, the 2 instruments correlated well. The Canon OCT-HS100 is a reproducible instrument that matches the Zeiss Cirrus HD-OCT well. It remains to be evaluated how sensitive the Canon OCT-HS100 is to detect small subtle changes in optic disc parameters and macular nerve fiber layer thickness. Furthermore, due to the differences in thickness estimation, it is important to emphasize that SD-OCTs are not interchangeable.

  16. Realization of the manipulation of ultracold atoms with a reconfigurable nanomagnetic system of domain walls.

    Science.gov (United States)

    West, Adam D; Weatherill, Kevin J; Hayward, Thomas J; Fry, Paul W; Schrefl, Thomas; Gibbs, Mike R J; Adams, Charles S; Allwood, Dan A; Hughes, Ifan G

    2012-08-08

    Planar magnetic nanowires have been vital to the development of spintronic technology. They provide an unparalleled combination of magnetic reconfigurability, controllability, and scalability, which has helped to realize such applications as racetrack memory and novel logic gates. Microfabricated atom optics benefit from all of these properties, and we present the first demonstration of the amalgamation of spintronic technology with ultracold atoms. A magnetic interaction is exhibited through the reflection of a cloud of (87)Rb atoms at a temperature of 10 μK, from a 2 mm × 2 mm array of nanomagnetic domain walls. In turn, the incident atoms approach the array at heights of the order of 100 nm and are thus used to probe magnetic fields at this distance.

  17. A hysteresis phenomenon in NMR spectra of molecular nanomagnets Fe8: a resonant quantum tunneling system

    Science.gov (United States)

    Yamasaki, Tomoaki; Ueda, Miki; Maegawa, Satoru

    2003-05-01

    A molecular nanomagnet Fe8 with a total spin S=10 in the ground state attracts much attention as a substance which exhibits the quantum tunneling of magnetization below 300 mK. We performed 1H NMR measurements for a single crystal of Fe8 in temperature range between 20 and 800 mK. The spectra below 300 mK strongly depend on the sequence of the applied field and those in the positive and negative fields are not symmetric about zero field, while they are symmetric above 300 mK. We discuss the origin of this hysteresis phenomenon, relating to the initial spin state of molecules, the resonant quantum tunneling and the nuclear spin relaxation process.

  18. A hysteresis phenomenon in NMR spectra of molecular nanomagnets Fe8: a resonant quantum tunneling system

    International Nuclear Information System (INIS)

    Yamasaki, Tomoaki; Ueda, Miki; Maegawa, Satoru

    2003-01-01

    A molecular nanomagnet Fe8 with a total spin S=10 in the ground state attracts much attention as a substance which exhibits the quantum tunneling of magnetization below 300 mK. We performed 1 H NMR measurements for a single crystal of Fe8 in temperature range between 20 and 800 mK. The spectra below 300 mK strongly depend on the sequence of the applied field and those in the positive and negative fields are not symmetric about zero field, while they are symmetric above 300 mK. We discuss the origin of this hysteresis phenomenon, relating to the initial spin state of molecules, the resonant quantum tunneling and the nuclear spin relaxation process

  19. Reversal time of jump-noise magnetization dynamics in nanomagnets via Monte Carlo simulations

    Science.gov (United States)

    Parthasarathy, Arun; Rakheja, Shaloo

    2018-06-01

    The jump-noise is a nonhomogeneous Poisson process which models thermal effects in magnetization dynamics, with special applications in low temperature escape rate phenomena. In this work, we develop improved numerical methods for Monte Carlo simulation of the jump-noise dynamics and validate the method by comparing the stationary distribution obtained empirically against the Boltzmann distribution. In accordance with the Néel-Brown theory, the jump-noise dynamics display an exponential relaxation toward equilibrium with a characteristic reversal time, which we extract for nanomagnets with uniaxial and cubic anisotropy. We relate the jump-noise dynamics to the equivalent Landau-Lifshitz dynamics up to second order correction for a general energy landscape and obtain the analogous Néel-Brown theory's solution of the reversal time. We find that the reversal time of jump-noise dynamics is characterized by Néel-Brown theory's solution at the energy saddle point for small noise. For large noise, the magnetization reversal due to jump-noise dynamics phenomenologically represents macroscopic tunneling of magnetization.

  20. Speeding up nanomagnetic logic by DMI enhanced Pt/Co/Ir films

    Science.gov (United States)

    Ziemys, Grazvydas; Ahrens, Valentin; Mendisch, Simon; Csaba, Gyorgy; Becherer, Markus

    2018-05-01

    We investigated a new type of multilayer film for Nanomagnetic Logic with perpendicular anisotropy (pNML) enhanced by the Dzyaloshinskii-Moriya interaction (DMI). The DMI effect provides an additional energy term and widens the design space for pNML film optimization. In this work we added an Ir layer between Co and Pt to our standard pNML multilayer (ML) film stack - [Co/Pt]x4. Multilayer stacks of films with and w/o Ir were sputtered and patterned to nanowires of 400 nm width by means of focused ion beam lithography (FIB). For comparability of the films they were tuned to show identical anisotropy for multilayer stacks with and w/o Ir. The field-driven domain wall (DW) velocity in the nanowires was measured by using wide-field MOKE microscopy. We found a strong impact of Ir on the DW velocity being up to 2 times higher compared to the standard [Co/Pt]x4 ML films. Moreover, the maximum velocity is reached at much lower magnetic field, which is beneficial for pNML operation. These results pave the way for pNML with higher clocking rates and at the same time allow a further reduce power consumption.

  1. Agile machining and inspection thrust area team-on-machine probing / compatibility assessment of Parametric Technology Corporation (PTC) pro/CMM DMIS with Zeiss DMISEngine.

    Energy Technology Data Exchange (ETDEWEB)

    Wade, James Rokwel; Tomlinson, Kurt; Bryce, Edwin Anthony

    2008-09-01

    The charter goal of the Agile Machining and Inspection Thrust Area Team is to identify technical requirements, within the nuclear weapons complex (NWC), for Agile Machining and Inspection capabilities. During FY 2008, the team identified Parametric Technology Corporation (PTC) Pro/CMM as a software tool for use in off-line programming of probing routines--used for measurement--for machining and turning centers. The probing routine would be used for in-process verification of part geometry. The same Pro/CMM program used on the machine tool could also be employed for program validation / part verification using a coordinate measuring machine (CMM). Funding was provided to determine the compatibility of the Pro/CMM probing program with CMM software (Zeiss DMISEngine).

  2. Nonlocal vibration of Y-shaped CNT conveying nano-magnetic viscous fluid under magnetic field

    Directory of Open Access Journals (Sweden)

    A. Ghorbanpour Arani

    2015-06-01

    Full Text Available This study deals with the vibration and stability analysis of a Y-shaped single-walled carbon nanotube (SWCNT embedded in visco-Pasternak foundation and conveying nano-magnetic viscous fluid (NMF based on nonlocal elasticity theory and Euler–Bernoulli beam model. The fluid is two-phases due to the existence of magnetic nanoparticles which its volume fraction is much little in comparison with the base fluid where the influence of 2D magnetic field is taken into account. Also, Knudsen number is used to correct the velocity profile of fluid. The Galerkin method is applied to solve the equation of motion which is obtained by employing Hamilton’s principle. The detail parametric study is conducted, focusing on the combined effects of carbon nanotube and Y-shaped junction fitted at the downstream end, fluid velocity, Knudsen number and elastic medium. The results indicate that increasing the angle between centerline of the CNT and the downstream elbows decreases stability of system.

  3. Linear stability analysis of a levitated nanomagnet in a static magnetic field: Quantum spin stabilized magnetic levitation

    Science.gov (United States)

    Rusconi, C. C.; Pöchhacker, V.; Cirac, J. I.; Romero-Isart, O.

    2017-10-01

    We theoretically study the levitation of a single magnetic domain nanosphere in an external static magnetic field. We show that, apart from the stability provided by the mechanical rotation of the nanomagnet (as in the classical Levitron), the quantum spin origin of its magnetization provides two additional mechanisms to stably levitate the system. Despite the Earnshaw theorem, such stable phases are present even in the absence of mechanical rotation. For large magnetic fields, the Larmor precession of the quantum magnetic moment stabilizes the system in full analogy with magnetic trapping of a neutral atom. For low magnetic fields, the magnetic anisotropy stabilizes the system via the Einstein-de Haas effect. These results are obtained with a linear stability analysis of a single magnetic domain rigid nanosphere with uniaxial anisotropy in a Ioffe-Pritchard magnetic field.

  4. Magnetic switching of optical reflectivity in nanomagnet/micromirror suspensions: colloid displays as a potential alternative to liquid crystal displays.

    Science.gov (United States)

    Bubenhofer, S B; Athanassiou, E K; Grass, R N; Koehler, F M; Rossier, M; Stark, W J

    2009-12-02

    Two-particle colloids containing nanomagnets and microscale mirrors can be prepared from iron oxide nanoparticles, microscale metal flakes and high-density liquids stabilizing the mirror suspension against sedimentation by matching the constituent's density. The free Brownian rotation of the micromirrors can be magnetically controlled through an anisotropic change in impulse transport arising from impacts of the magnetic nanoparticles onto the anisotropic flakes. The resulting rapid mirror orientation allows large changes in light transmission and switchable optical reflectivity. The preparation of a passive display was conceptually demonstrated through colloid confinement in a planar cavity over an array of individually addressable solenoids and resulted in 4 x 4 digit displays with a reaction time of less than 100 ms.

  5. Mechanisms of relaxation and spin decoherence in nanomagnets

    Science.gov (United States)

    van Tol, Johan

    Relaxation in spin systems is of great interest with respect to various possible applications like quantum information processing and storage, spintronics, and dynamic nuclear polarization (DNP). The implementation of high frequencies and fields is crucial in the study of systems with large zero-field splitting or large interactions, as for example molecular magnets and low dimensional magnetic materials. Here we will focus on the implementation of pulsed Electron Paramagnetic Resonance (ERP) at multiple frequencies of 10, 95, 120, 240, and 336 GHz, and the relaxation and decoherence processes as a function of magnetic field and temperature. Firstly, at higher frequencies the direct single-phonon spin-lattice relaxation (SLR) is considerably enhanced, and will more often than not be the dominant relaxation mechanism at low temperatures, and can be much faster than at lower fields and frequencies. In principle the measurement of the SLR rates as a function of the frequency provides a means to map the phonon density of states. Secondly, the high electron spin polarization at high fields has a strong influence on the spin fluctuations in relatively concentrated spin systems, and the contribution of the electron-electron dipolar interactions to the coherence rate can be partially quenched at low temperatures. This not only allows the study of relatively concentrated spin systems by pulsed EPR (as for example magnetic nanoparticles and molecular magnets), it enables the separation of the contribution of the fluctuations of the electron spin system from other decoherence mechanisms. Besides choice of temperature and field, several strategies in sample design, pulse sequences, or clock transitions can be employed to extend the coherence time in nanomagnets. A review will be given of the decoherence mechanisms with an attempt at a quantitative comparison of experimental rates with theory.

  6. Nanomagnet-based removal of lead and digoxin from living rats

    Science.gov (United States)

    Herrmann, Inge K.; Schlegel, Andrea; Graf, Rolf; Schumacher, Christoph M.; Senn, Nico; Hasler, Melanie; Gschwind, Sabrina; Hirt, Ann-Marie; Günther, Detlef; Clavien, Pierre-Alain; Stark, Wendelin J.; Beck-Schimmer, Beatrice

    2013-08-01

    In a number of clinical conditions such as intoxication, bacteraemia or autoimmune diseases the removal of the disease-causing factor from blood would be the most direct cure. However, physicochemical characteristics of the target compounds limit the applicability of classical filtration and diffusion-based processes. In this work, we present a first in vivo magnetic blood purification rodent animal model and demonstrate its ability to rapidly clear toxins from blood circulation using two model toxins with stable plasma levels (lead (Pb2+) and digoxin). Ultra-strong functionalized metal nanomagnets are employed to eliminate the toxin from whole blood in an extracorporeal circuit. In the present experimental demonstration over 40% of the toxin (i.e. lead or digoxin) was removed within the first 10 minutes and over 75% within 40 minutes. After capturing the target substance, a magnetic trap prevents the toxin-loaded nanoparticles from entering the blood circulation. Elemental analysis and magnetic hysteresis measurements confirm full particle recovery by simple magnetic separation (residual particle concentration below 1 μg mL-1 (detection limit)). We demonstrate that magnetic separation-based blood purification offers rapid blood cleaning from noxious agents, germs or other deleterious materials with relevance to a number of clinical conditions. Based on this new approach, current blood purification technologies can be extended to efficiently remove disease-causing factors, e.g. overdosed drugs, bacteria or cancer cells without being limited by filter cut-offs or column surface saturation.

  7. Spin-frustrated V3 and Cu3 nanomagnets with Dzialoshinsky-Moriya exchange. 2. Spin structure, spin chirality and tunneling gaps

    International Nuclear Information System (INIS)

    Belinsky, Moisey I.

    2009-01-01

    The spin chirality and spin structure of the Cu 3 and V 3 nanomagnets with the Dzialoshinsky-Moriya (DM) exchange interaction are analyzed. The correlations between the vector κ and the scalar χ chirality are obtained. The DM interaction forms the spin chirality which is equal to zero in the Heisenberg clusters. The dependences of the spin chirality on magnetic field and deformations are calculated. The cluster distortions reduce the spin chirality. The vector chirality is reduced partially and the scalar chirality vanishes in the transverse magnetic field. In the isosceles clusters, the DM exchange and distortions determine the sign and degree of the spin chirality κ. The correlations between the chirality parameters κ n and the intensities of the EPR and INS transitions are obtained. The vector chirality κ n describes the spin chirality of the Cu 3 and V 3 nanomagnets, the scalar chirality describes the pseudoorbital moment of the DM cluster. It is shown that in the consideration of the DM exchange, the spin states DM mixing and tunneling gaps at level crossing fields depend on the coordinate system of the DM model. The calculations in the DM exchange models in the right-handed and left-handed frame show opposite magnetic behavior at the level crossing field and allow to explain the opposite schemes of the tunneling gaps and levels crossing, which have been obtained in different treatments. The results of the DM model in the right-handed frame are consistent with the results of the group-theoretical analysis, whereas the results in the left-handed frame are inconsistent with that. The correlations between the spin chirality of the ground state and tunneling gaps at the level crossing field are obtained for the equilateral and isosceles nanoclusters.

  8. Structural and magnetic properties of Mn{sub 12}-Stearate nanomagnets

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Shilpi [Quantum Phenomena and Applications Division, National Physical Laboratory, Dr K. S. Krishnan Road, New Delhi 110012 (India); Academy of Scientific and Innovative Research (AcSIR), Chennai 600113 (India); Verma, Apoorva [Quantum Phenomena and Applications Division, National Physical Laboratory, Dr K. S. Krishnan Road, New Delhi 110012 (India); Srivastava, Avanish K. [Electron and Ion Microscopy Division, National Physical Laboratory, Dr K. S. Krishnan Road, New Delhi 110012 (India); Gupta, Anurag, E-mail: anurag@mail.nplindia.org [Quantum Phenomena and Applications Division, National Physical Laboratory, Dr K. S. Krishnan Road, New Delhi 110012 (India); Singh, Surinder P. [Electron and Ion Microscopy Division, National Physical Laboratory, Dr K. S. Krishnan Road, New Delhi 110012 (India); Academy of Scientific and Innovative Research (AcSIR), Chennai 600113 (India); Singh, Priti, E-mail: pritichem@gmail.com [Quantum Phenomena and Applications Division, National Physical Laboratory, Dr K. S. Krishnan Road, New Delhi 110012 (India); Academy of Scientific and Innovative Research (AcSIR), Chennai 600113 (India)

    2016-07-01

    We present the synthesis and characterization of a fatty acid ligated Mn{sub 12}, [Mn{sub 12}O{sub 12}(CH{sub 3}(CH{sub 2}){sub 16}CO{sub 2}){sub 11}(CH{sub 3}CO{sub 2}){sub 5}(H{sub 2}O){sub 4}], Mn{sub 12}-Stearate (2), a molecular nanomagnet of Mn{sub 12} family that exhibits the enhanced solubility (in organic solvents) and aqueous stability. The chemical composition and morphology of Mn{sub 12}-Stearate have been established using FT-IR, UV–Vis, Raman and {sup 1}H NMR spectroscopy, XRD, elemental analysis, TGA and electron microscopic techniques. The powder XRD and HR-TEM of compound 2 have revealed the formation of crystalline structure. The FC and ZFC magnetization (M) as a function of temperature (T) shows a blocking temperature T{sub B} ∼ 3.0 K. At T ≤ 3 K, the presence of hysteresis and periodic steps in the measured M-H loops indicate the presence of quantum tunnelling of magnetization (QTM). In the same T region, the observed decrease of magnetic relaxation rate with a decrease in T further implies the QTM to be thermally assisted. The estimated anisotropy energy barrier is found to be ∼35 K. - Highlights: • A fatty acid ligated mixed-carboxylate SMM, Mn{sub 12}-Stearate, has been synthesized. • Powder XRD and HRTEM images show crystalline ordering in the synthesized cluster. • The cluster exhibits higher blocking temperature and periodic steps in hysteresis.

  9. Nanoscale zero-valent iron incorporated with nanomagnetic diatomite for catalytic degradation of methylene blue in heterogeneous Fenton system.

    Science.gov (United States)

    Zha, Yiming; Zhou, Ziqing; He, Haibo; Wang, Tianlin; Luo, Liqiang

    2016-01-01

    Nanoscale zero-valent iron (nZVI) incorporated with nanomagnetic diatomite (DE) composite material was prepared for catalytic degradation of methylene blue (MB) in heterogeneous Fenton system. The material was constructed by two facile steps: Fe3O4 magnetic nanoparticles were supported on DE by chemical co-precipitation method, after which nZVI was incorporated into magnetic DE by liquid-phase chemical reduction strategy. The as-prepared catalyst was characterized by scanning electron microscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, magnetic properties measurement and nitrogen adsorption-desorption isotherm measurement. The novel nZVI@Fe3O4-diatomite nanocomposites showed a distinct catalytic activity and a desirable effect for degradation of MB. MB could be completely decolorized within 8 min and the removal efficiency of total organic carbon could reach to 90% after reaction for 1 h.

  10. Quantum Interference in the Longitudinal Oscillations of the Total Spin of a Dimeric Molecular Nanomagnet

    Science.gov (United States)

    Ramsey, Christopher; Del Barco, Enrique; Hill, Stephen; Shah, Sonali; Beedle, Christopher; Hendrickson, David

    2008-03-01

    The synthetic flexibility of molecular magnets allows one to systematically produce samples with desirable properties such as those with entangled spin states for implementation in quantum logic gates. Here we report direct evidence of quantum oscillations of the total spin length of a dimeric molecular nanomagnet through the observation of quantum interference associated with tunneling trajectories between states having different spin quantum numbers. As we outline, this is a consequence of the unique characteristics of a molecular Mn12 wheel which behaves as a (weak) ferromagnetic exchange-coupled molecular dimer: each half of the molecule acts as a single-molecule magnet (SMM), while the weak coupling between the two halves gives rise to an additional internal spin degree of freedom within the molecule, namely that its total spin may fluctuate. This extra degree of freedom accounts for several magnetization tunneling resonances that cannot be explained within the usual giant spin approximation. More importantly, the observation of quantum interference provides unambiguous evidence for the quantum mechanical superposition involving entangled states of both halves of the wheel.

  11. 13C NMR and relaxation studies of the nanomagnet Mn12-acetate

    Science.gov (United States)

    Achey, Randall M.; Kuhns, Philip L.; Reyes, Arneil P.; Moulton, William G.; Dalal, Naresh S.

    2001-08-01

    The nanomagnet [Mn12O12(CH3COO)16(H2O)4].2CH3COOH.4H2O, also known as Mn12, has been synthesized with 13C labeling at the CH3 groups, and investigated by 13C NMR at fields up to 23 T. Using oriented samples, it is possible to resolve four distinct 13C peaks at room temperature, located on both sides of the unshifted Larmor frequency. These peaks were assigned to the four hyperfine-shifted, magnetically inequivalent sets of 13CH3 groups in the Mn12 lattice, based on a comparison with the crystal structure and point-dipole and spin-density calculations. These results establish that the unpaired electron spin density of the S=10 system in this cluster extends over the entire molecular framework, not just the core. These results are discussed in relationship to inelastic neutron scattering measurements. The temperature and field dependence of the 13C nuclear-spin-lattice-relaxation time T1 on the least shifted peak was measured. A single weakly field-dependent minimum at about 60 K is observed in the temperature dependence of the measured T1. The relaxation mechanism responsible for the T1 minimum is ascribed mainly to hindered rotation of the methyl group of the acetate ligand at higher temperature, and to electronic spin fluctuations at lower temperature.

  12. EELS data acquisition, processing and display for the Zeiss CEM 902 based on LOTUS 1-2-3: application examples from a biological system and inorganic transition metal compounds.

    Science.gov (United States)

    Drechsler, M; Cantow, H J

    1991-04-01

    A personal computer combined with LOTUS 1-2-3 software, including the RS232 module of LOTUS MEASURE and a 12-bit ADC, has been used for data acquisition of electron energy-loss spectroscopy (EELS) spectra with the Zeiss CEM 902. The internal macro language of LOTUS 1-2-3 allows a menu-driven procedure. Macro-programs partly combined with external FORTRAN programs can be chosen from the menu for background subtraction, removal of multiple scattering effects by deconvolution, elemental quantification and several utilities. For special applications or conditions the macro programs can easily be modified. Spectra from crystals of two inorganic transition metal compounds, ruthenium trichloride and vanadium disulphide, and from a biological sample are presented as examples of the application of this software.

  13. Acquisition of an Electron Back Scatter Diffraction (EBSD) system for the Zeiss Sigma SEM at Portland State University -- Planetary Major Equipment

    Science.gov (United States)

    Ruzicka, Alex

    To build on our parent Origins program award, entitled "Shock histories of chondrites as revealed by combined microstructural (TEM), petrographic, and X-ray microtomographic (micro-CT) analysis", we are requesting as Planetary Major Equipment the acquisition of an Electron Back Scatter Diffraction (EBSD) system, which will integrate with a Zeiss Sigma SEM that was installed at Portland State University last year (2010). This EBSD system will greatly augment the science return of the parent grant by allowing quantitative measurements of strain and textural fabrics in grains of all sizes and types across an entire thin section. Such measurements will help link data that are already being obtained with optical light microscopy, transmission electron microscopy, and micro- tomography methods. More generally, the EBSD system will augment the PI's research on the petrology of extraterrestrial materials by providing an additional tool for petrographic analyses, with data that can be used to evaluate strain, grain orientations, grain size distributions, phase proportions, and mineralogy. The equipment will enable quantitative characterization of the crystallography of primitive extraterrestrial materials, which will contribute to a better understanding of the formation and evolution of planetary systems, a major goal of NASA.

  14. Acquisition of an Electron Back Scatter Diffraction (EBSD) system for the Zeiss Sigma SEM at Portland State University Planetary Major Equipment

    Science.gov (United States)

    Ruzicka, Alex

    To build on our parent Origins program award, entitled "Shock histories of chondrites as revealed by combined microstructural (TEM), petrographic, and X-ray microtomographic (micro-CT) analysis", we are requesting as Planetary Major Equipment the acquisition of an Electron Back Scatter Diffraction (EBSD) system, which will integrate with a Zeiss Sigma SEM that was installed at Portland State University last year (2010). This EBSD system will greatly augment the science return of the parent grant by allowing quantitative measurements of strain and textural fabrics in grains of all sizes and types across an entire thin section. Such measurements will help link data that are already being obtained with optical light microscopy, transmission electron microscopy, and micro- tomography methods. More generally, the EBSD system will augment the PI's research on the petrology of extraterrestrial materials by providing an additional tool for petrographic analyses, with data that can be used to evaluate strain, grain orientations, grain size distributions, phase proportions, and mineralogy. The equipment will enable quantitative characterization of the crystallography of primitive extraterrestrial materials, which will contribute to a better understanding of the formation and evolution of planetary systems, a major goal of NASA.

  15. Magnetization switching and microwave oscillations in nanomagnets driven by spin-polarized currents

    International Nuclear Information System (INIS)

    Bertotti, G.; Magni, A.; Serpico, C.; d'Aquino, M.; Mayergoyz, I. D.; Bonin, R.

    2005-01-01

    Full text: Considerable interest has been generated in recent years by the discovery that a current of spin-polarized electrons can apply appreciable torques to a nanoscale ferromagnet. This mechanism was theoretically predicted and subsequently confirmed by a number of experiments which have shown that spin transfer can indeed induce switching or microwave oscillations of the magnetization. Significant efforts have been devoted to the explanation of these results, in view of the new physics involved and of the possible applications to new types of current-controlled memory cells or microwave sources and resonators . However, the precise nature of magnetization dynamics when spin-polarized currents and external magnetic fields are simultaneously present has not yet been fully understood. The spin-transfer-driven nanomagnet is a nonlinear open system that is forced far from equilibrium by the injection of the current. Thus, the appropriate framework for the study of the problem is nonlinear dynamical system theory and bifurcation theory. In this talk, it is shown that within this framework the complexity and subtlety of spin-torque effects are fully revealed and quantified, once it is recognized that both intrinsic damping and spin transfer can be treated as perturbations of the free precessional dynamics typical of ferromagnetic resonance. Complete stability diagrams are derived for the case where spin torques and external magnetic fields are simultaneously present. Quantitative predictions are made for the critical currents and fields inducing magnetization switching; for the amplitude and frequency of magnetization self-oscillations; for the conditions leading to hysteretic transitions between self-oscillations and stationary states

  16. Preparation, characterization, and efficient transfection of cationic liposomes and nanomagnetic cationic liposomes

    Directory of Open Access Journals (Sweden)

    Samadikhah HR

    2011-10-01

    Full Text Available Hamid Reza Samadikhah1,*, Asia Majidi2,*, Maryam Nikkhah2, Saman Hosseinkhani11Department of Biochemistry, 2Department of Nanobiotechnology, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, Iran *These authors contributed equally to this work Purpose: Cationic liposomes (CLs are composed of phospholipid bilayers. One of the most important applications of these particles is in drug and gene delivery. However, using CLs to deliver therapeutic nucleic acids and drugs to target organs has some problems, including low transfection efficiency in vivo. The aim of this study was to develop novel CLs containing magnetite to overcome the deficiencies. Patients and methods: CLs and magnetic cationic liposomes (MCLs were prepared using the freeze-dried empty liposome method. Luciferase-harboring vectors (pGL3 were transferred into liposomes and the transfection efficiencies were determined by luciferase assay. Firefly luciferase is one of most popular reporter genes often used to measure the efficiency of gene transfer in vivo and in vitro. Different formulations of liposomes have been used for delivery of different kinds of gene reporters. Lipoplex (liposome–plasmid DNA complexes formation was monitored by gel retardation assay. Size and charge of lipoplexes were determined using particle size analysis. Chinese hamster ovary cells were transfected by lipoplexes (liposome-pGL3; transfection efficiency and gene expression level was evaluated by luciferase assay. Results: High transfection efficiency of plasmid by CLs and novel nanomagnetic CLs was achieved. Moreover, lipoplexes showed less cytotoxicity than polyethyleneimine and Lipofectamine™. Conclusion: Novel liposome compositions (1,2-dipalmitoyl-sn-glycero-3-phosphocholine [DPPC]/dioctadecyldimethylammonium bromide [DOAB] and DPPC/cholesterol/DOAB with high transfection efficiency can be useful in gene delivery in vitro. MCLs can also be used for targeted gene delivery, due to

  17. From micro- to nanomagnetic dots: evolution of the eigenmode spectrum on reducing the lateral size

    International Nuclear Information System (INIS)

    Carlotti, G; Madami, M; Gubbiotti, G; Tacchi, S; Hartmann, F; Emmerling, M; Kamp, M; Worschech, L

    2014-01-01

    Brillouin light scattering experiments and micromagnetic simulations have been exploited to investigate the spectrum of thermally excited magnetic eigenmodes in 10 nm-thick elliptical Permalloy dots, when the longer axis D is scaled down from about 1000 to 100 nm. It is shown that for D larger than about 200 nm the characteristics of the spin-wave eigenmodes are dominated by dipolar energy, while for D in the range of about 100 to 200 nm exchange energy effects cause qualitative and quantitative differences in the spin-wave spectrum. In this ‘mesoscopic’ regime, the usual classification scheme, involving one fundamental mode with large average magnetization and many other modes collected in families with specific symmetries, no longer holds. Rather, one finds the simultaneous presence of two modes with ‘fundamental’ character, i.e. with a significant and comparable value of the average dynamical magnetization: the former is at larger frequency and has its maximum amplitude at the dot's centre, while the latter occurs at lower frequency and is localized at the dot's edges. Interestingly, the maximum intensity swaps from the higher frequency mode to the lower frequency one, just when the dot size is reduced from about 200 to 100 nm. This is relevant in view of the exploitation of nanodots for the design of nanomagnetic devices with lateral dimensions in the above interval, such as memory cells, logic gates, reading heads and spin-torque oscillators. (paper)

  18. From micro- to nanomagnetic dots: evolution of the eigenmode spectrum on reducing the lateral size

    Science.gov (United States)

    Carlotti, G.; Gubbiotti, G.; Madami, M.; Tacchi, S.; Hartmann, F.; Emmerling, M.; Kamp, M.; Worschech, L.

    2014-07-01

    Brillouin light scattering experiments and micromagnetic simulations have been exploited to investigate the spectrum of thermally excited magnetic eigenmodes in 10 nm-thick elliptical Permalloy dots, when the longer axis D is scaled down from about 1000 to 100 nm. It is shown that for D larger than about 200 nm the characteristics of the spin-wave eigenmodes are dominated by dipolar energy, while for D in the range of about 100 to 200 nm exchange energy effects cause qualitative and quantitative differences in the spin-wave spectrum. In this ‘mesoscopic’ regime, the usual classification scheme, involving one fundamental mode with large average magnetization and many other modes collected in families with specific symmetries, no longer holds. Rather, one finds the simultaneous presence of two modes with ‘fundamental’ character, i.e. with a significant and comparable value of the average dynamical magnetization: the former is at larger frequency and has its maximum amplitude at the dot's centre, while the latter occurs at lower frequency and is localized at the dot's edges. Interestingly, the maximum intensity swaps from the higher frequency mode to the lower frequency one, just when the dot size is reduced from about 200 to 100 nm. This is relevant in view of the exploitation of nanodots for the design of nanomagnetic devices with lateral dimensions in the above interval, such as memory cells, logic gates, reading heads and spin-torque oscillators.

  19. Avaliação do desempenho visual da lente intraocular difrativa multifocal - Zeiss AT Lisa 809 MTM

    Directory of Open Access Journals (Sweden)

    Lucas Monferrari Monteiro Vianna

    2014-04-01

    Full Text Available Objetivo: Avaliar a função visual dos pacientes com implante bilateral da LIO multifocal difrativa AT-Lisa 809 MTM por meio dos exames de acuidade visual com e sem correção óptica, curva de sensibilidade ao contraste, curva de desfoco e questionário de qualidade de função visual (VQF39. Métodos: Estudo clínico, prospectivo e de intervenção, que avaliou os resultados de 20 olhos de 10 pacientes, submetidos à facoemulsificação e implante de LIO, entre fevereiro e junho de 2012. Resultados: A ametropia residual média pós-operatória foi de 0,05 ± 0,42 (-0,75 a +1,25 D dioptrias esféricas e -0,30 ± 0,42 (0 a -1,25 D dioptrias cilíndricas. Na curva de desenfoque mono e binocular, a melhor acuidade visual média obtida com 0.00 D de desenfoque (AV de longe. O segundo pico foi obtido com desenfoque de -3,00 D, o que equivale à visão de perto a 33 cm. Entre esses picos, observamos uma perda de desempenho visual, com desenfoque de -2,00 D, que equivale a visão intermediária a 50 cm. A sensibilidade ao contraste foi similar aos relatados na literatura com este tipo de LIO, tanto com quanto sem ofuscamento, e é mostrada em gráficos. O questionário de função visual (VFQ-39 teve valor médio de 91,91 +- 6,82. Conclusão: A LIO multifocal difrativa AT-Lisa 809MTM (Carl Zeiss Meditec Company - Alemanha apresentou resultados condizentes com a literatura quando avaliada pelos exames de acuidade visual com e sem correção óptica, sensibilidade ao contraste, curva de desfoco e questionário de qualidade de função visual (VQF 39.

  20. Magnetization switching of a metallic nanomagnet via current-induced surface spin-polarization of an underlying topological insulator

    International Nuclear Information System (INIS)

    Roy, Urmimala; Dey, Rik; Pramanik, Tanmoy; Ghosh, Bahniman; Register, Leonard F.; Banerjee, Sanjay K.

    2015-01-01

    We consider a thermally stable, metallic nanoscale ferromagnet (FM) subject to spin-polarized current injection and exchange coupling from the spin-helically locked surface states of a topological insulator (TI) to evaluate possible non-volatile memory applications. We consider parallel transport in the TI and the metallic FM, and focus on the efficiency of magnetization switching as a function of transport between the TI and the FM. Transport is modeled as diffusive in the TI beneath the FM, consistent with the mobility in the TI at room temperature, and in the FM, which essentially serves as a constant potential region albeit spin-dependent except in the low conductivity, diffusive limit. Thus, it can be captured by drift-diffusion simulation, which allows for ready interpretation of the results. We calculate switching time and energy consumed per write operation using self-consistent transport, spin-transfer-torque (STT), and magnetization dynamics calculations. Calculated switching energies and times compare favorably to conventional spin-torque memory schemes for substantial interlayer conductivity. Nevertheless, we find that shunting of current from the TI to a metallic nanomagnet can substantially limit efficiency. Exacerbating the problem, STT from the TI effectively increases the TI resistivity. We show that for optimum performance, the sheet resistivity of the FM layer should be comparable to or larger than that of the TI surface layer. Thus, the effective conductivity of the FM layer becomes a critical design consideration for TI-based non-volatile memory

  1. Spin Chirality of Cu3 and V3 Nanomagnets. 1. Rotation Behavior of Vector Chirality, Scalar Chirality, and Magnetization in the Rotating Magnetic Field, Magnetochiral Correlations.

    Science.gov (United States)

    Belinsky, Moisey I

    2016-05-02

    The rotation behavior of the vector chirality κ, scalar chirality χ, and magnetization M in the rotating magnetic field H1 is considered for the V3 and Cu3 nanomagnets, in which the Dzialoshinsky-Moriya coupling is active. The polar rotation of the field H1 of the given strength H1 results in the energy spectrum characterized by different vector and scalar chiralities in the ground and excited states. The magnetochiral correlations between the vector and scalar chiralities, energy, and magnetization in the rotating field were considered. Under the uniform polar rotation of the field H1, the ground-state chirality vector κI performs sawtooth oscillations and the magnetization vector MI performs the sawtooth oscillating rotation that is accompanied by the correlated transformation of the scalar chirality χI. This demonstrates the magnetochiral effect of the joint rotation behavior and simultaneous frustrations of the spin chiralities and magnetization in the rotating field, which are governed by the correlation between the chiralities and magnetization.

  2. Micromagnetic simulation of exploratory magnetic logic device with missing corner defect

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiaokuo, E-mail: yangxk0123@163.com; Cai, Li; Zhang, Bin; Cui, Huanqing; Zhang, Mingliang

    2015-11-15

    Magnetic film nanostructures are attractive components of nonvolatile magnetoresistive memories and nanomagnet logic circuits. Recently, we studied switching properties (i.e., null logic preserving) of rectangle shape nanomagnet subjected to fabrication imperfections. Specifically, we presented typical missing corner material-related imperfections and adopted an isosceles triangle to model this defect for nanomagnets. Micromagnetic simulation shows that this kind of imperfections modeling method agrees well with previous experimental observations. Using the proposed defect modeling scheme, we investigate in detail the switching characteristics of different defective stand-alone and coupled nanomagnets. The results suggest that the state transition of defective nanomagnet element highly depends on defect type and device’s aspect ratio, and the defect type B{sub d} needs the largest coercive field, while the defect type D requires the largest null field for switching. These findings can provide key technical parameters and guides for nanomagnet logic circuit design. - Highlights: • We have modeled missing corner defect issue for nanomagnet logic device. • The logic state of defective NML element highly depends on defect type and AR. • The NML device with defect type B{sub d} needs the largest coercive field to reverse state. • The defect type D in the NML devices requires the largest null field to switch.

  3. The Role of Antisymmetric Exchange on the Quantum Interference between States of Different Spin Length in a dimeric Molecular Nanomagnet.

    Science.gov (United States)

    Del Barco, Enrique

    2009-03-01

    We report direct evidence of quantum oscillations of the total spin length of a dimeric molecular nanomagnet through the observation of quantum interference associated with tunneling trajectories between states having different spin quantum numbers. As we outline, this is a consequence of the unique characteristics of a molecular Mn12 wheel which behaves as a (weak) ferromagnetic exchange-coupled molecular dimer: each half of the molecule acts as a single-molecule magnet (SMM), while the weak coupling between the two halves gives rise to an additional internal spin degree of freedom within the molecule, namely that its total spin may fluctuate. This extra degree of freedom accounts for several magnetization tunneling resonances that cannot be explained within the usual giant spin approximation. More importantly, the observation of quantum interference provides unambiguous evidence for the quantum mechanical superposition involving entangled states of both halves of the wheel. Magnetization results obtained in two other versions of this compound, in which the ligands have been modified, show that slight variations of the relative distance between the Mn ions determine whether the molecule behaves as a rigid magnetic unit of spin S = 7 or as two exchange-coupled halves of spin S = 7/2. We analyze the effect of the Dzyaloshinskii-Moriya antisymmetric exchange interaction in a molecule with a centre of inversion symmetry and propose a formal model to account for the observed broken degeneracy that preserves the molecular inversion symmetry.

  4. Spin nutation effects in molecular nanomagnet–superconductor tunnel junctions

    International Nuclear Information System (INIS)

    Abouie, J; Abdollahipour, B; Rostami, A A

    2013-01-01

    We study the spin nutation effects of a molecular nanomagnet on the Josephson current through a superconductor|molecular nanomagnet|superconductor tunnel junction. We explicitly demonstrate that, due to the spin nutation of the molecular nanomagnet, two oscillatory terms emerge in the ac Josephson current in addition to the conventional ac Josephson current. Some resonances occur in the junction due to the interactions of the transported quasiparticles with the bias voltage and molecular nanomagnet spin dynamics. Their appearance indicates that the energy exchanged during these interactions is in the range of the superconducting energy gap. We also show that the spin nutation is able to convert the ac Josephson current to a dc current, which is interesting for applications. (paper)

  5. Automatization Project for the Carl-Zeiss-Jena Coudè Telescope of the Simón Bolívar Planetarium I. The Electro-Mechanic System

    Science.gov (United States)

    Núñez, A.; Maharaj, A.; Muñoz, A. G.

    2009-05-01

    The ``Complejo Científico, Cultural y Turístico Simón Bolívar'' (CCCTSB), located in Maracaibo, Venezuela, lodges the Simón Bolívar Planetarium and an 150 mm aperture, 2250 mm focal length Carl-Zeiss-Jena Coudè refractor telescope. In this work we discuss the schematics for the automatization project of this Telescope, the planned improvements, methodology, engines, micro-controllers, interfaces and the uptodate status of the project. This project is working on the first two levels of the automation pyramid, the sensor -- actuator level and the control or Plant floor level. The Process control level correspond to the software related section. This mean that this project work immediately with the electrical, electronic and mechanical stuffs, and with the assembler micro controller language. All the pc related stuff, like GUI (Graphic user interfaces), remote control, Grid database, and others, correspond to the next two automation pyramid levels. The idea is that little human intervention will be required to manipulate the telescope, only giving a pair of coordinates to ubicate and follow an object on the sky. A set of three servomotors, coupling it with the telescope with a gear box, are going to manipulate right ascension, declination and focus movement. For the dome rotation, a three phase induction motor will be used. For dome aperture/closure it is suggested a DC motor powered with solar panels. All those actuators are controlled by a 8 bits micro-controller, which receive the coordinate imput, the signal from the position sensors and have the PID control algorithm. This algorithm is tuned based on the mathematical model of the telescope electro-mechanical instrumentation.

  6. The effect of the size of the system, aspect ratio and impurities concentration on the dynamic of emergent magnetic monopoles in artificial spin ice systems

    Science.gov (United States)

    León, Alejandro

    2013-08-01

    In this work we study the dynamical properties of a finite array of nanomagnets in artificial kagome spin ice at room temperature. The dynamic response of the array of nanomagnets is studied by implementing a "frustrated celular autómata" (FCA), based in the charge model and dipolar model. The FCA simulations allow us to study in real-time and deterministic way, the dynamic of the system, with minimal computational resource. The update function is defined according to the coordination number of vertices in the system. Our results show that for a set geometric parameters of the array of nanomagnets, the system exhibits high density of Dirac strings and high density emergent magnetic monopoles. A study of the effect of disorder in the arrangement of nanomagnets is incorporated in this work.

  7. Mixed hemimicelles solid-phase extraction based on sodium dodecyl sulfate (SDS)-coated nano-magnets for the spectrophotometric determination of Fingolomid in biological fluids

    Science.gov (United States)

    Azari, Zhila; Pourbasheer, Eslam; Beheshti, Abolghasem

    2016-01-01

    In this study, mixed hemimicelles solid-phase extraction (SPE) based on sodium dodecyl sulfate (SDS)-coated nano-magnets Fe3O4 was investigated as a novel method for the separation and determination of Fingolimod (FLM) in water, urine and plasma samples prior to spectrophotometeric determination. Due to the high surface area of these new sorbents and the excellent adsorption capacity after surface modification by SDS, satisfactory extraction recoveries can be produced. The main factors affecting the adsolubilization of analysts, such as pH, surfactant and adsorbent amounts, ionic strength, extraction time and desorption conditions were studied and optimized. Under the selected conditions, FLM has been quantitatively extracted. The accuracy of the method was evaluated by recovery measurements on spiked samples, and good recoveries of 96%, 95% and 88% were observed for water, urine and plasma respectively. Proper linear behaviors over the investigated concentration ranges of 2-26, 2-17 and 2-13 mg/L with good coefficients of determination, 0.998, 0.997 and 0.995 were achieved for water, urine and plasma samples, respectively. To the best of our knowledge, this is the first time that a mixed hemimicelles SPE method based on magnetic separation and nanoparticles has been used as a simple and sensitive method for monitoring of FLM in water and biological samples.

  8. Magnetic force microscopy and simulation studies on Co 50 Fe 50 ...

    Indian Academy of Sciences (India)

    We studied the magnetization reversal mechanism of single-layered Co50Fe50 nanomagnets by measuring the magnetization reversal and using the micromagnetic simulations. The magnetization reversal strongly depends on the thickness of the nanomagnets. In the remanent state, the magnetic force microscopy studies ...

  9. Study of system-size effects on the emergent magnetic monopoles and Dirac strings in artificial kagome spin ice

    Science.gov (United States)

    Leon, Alejandro

    2012-02-01

    In this work we study the dynamical properties of a finite array of nanomagnets in artificial kagome spin ice at room temperature. The dynamic response of the array of nanomagnets is studied by implementing a ``frustrated celular aut'omata'' (FCA), based in the charge model. In this model, each dipole is replaced by a dumbbell of two opposite charges, which are situated at the neighbouring vertices of the honeycomb lattice. The FCA simulations, allow us to study in real-time and deterministic way, the dynamic of the system, with minimal computational resource. The update function is defined according to the coordination number of vertices in the system. Our results show that for a set geometric parameters of the array of nanomagnets, the system exhibits high density of Dirac strings and high density emergent magnetic monopoles. A study of the effect of disorder in the arrangement of nanomagnets is incorporated in this work.

  10. Nanomagnetics

    CERN Document Server

    Skomski, R

    2003-01-01

    Magnetic nanostructures, such as dots and dot arrays, nanowires, multilayers and nanojunctions, are reviewed and compared with bulk magnets. The emphasis is on the involved physics, but some applications are also outlined, including permanent magnets, soft magnets, magnetic recording media, sensors, and structures and materials for spin electronics. The considered structural length scales range from a few interatomic distances to about one micrometre, bridging the gap between atomic-scale magnetism and the macroscopic magnetism of extended bulk and thin-film magnets. This leads to a rich variety of physical phenomena, differently affecting intrinsic and extrinsic magnetic properties. Some specific phenomena discussed in this review are exchange-spring magnetism, random-anisotropy scaling, narrow-wall and constricted-wall phenomena, Curie temperature changes due to nanostructuring and nanoscale magnetization dynamics. (topical review)

  11. Josephson Junction as a Magnetic Switch

    Science.gov (United States)

    Cai, Liufei; Chudnovsky, Eugene

    2011-03-01

    We study electromagnetic interaction of a nanomagnet with a weak superconducting link. Equations that govern coupled dynamics of the two systems are derived and investigated numerically. We show that despite very weak magnetic field generated by the weak link, a time-dependent bias voltage applied to the link can initiate a non-linear dynamics of the nanomagnet that leads to the reversal of its magnetic moment. We also consider quantum problem in which a nanomagnet interacting with a weak link is treated as a two-state spin system due to quantum tunneling between spin-up and spin-down states. L. Cai and E. M. Chudnovsky, Phys. Rev B 82, 104429 (2010).

  12. The effect of the size of the system, aspect ratio and impurities concentration on the dynamic of emergent magnetic monopoles in artificial spin ice systems

    Energy Technology Data Exchange (ETDEWEB)

    León, Alejandro, E-mail: alejandro.leon@udp.cl

    2013-08-15

    In this work we study the dynamical properties of a finite array of nanomagnets in artificial kagome spin ice at room temperature. The dynamic response of the array of nanomagnets is studied by implementing a “frustrated celular autómata” (FCA), based in the charge model and dipolar model. The FCA simulations allow us to study in real-time and deterministic way, the dynamic of the system, with minimal computational resource. The update function is defined according to the coordination number of vertices in the system. Our results show that for a set geometric parameters of the array of nanomagnets, the system exhibits high density of Dirac strings and high density emergent magnetic monopoles. A study of the effect of disorder in the arrangement of nanomagnets is incorporated in this work. - Highlights: • The dynamics of magnetic monopoles in spin ice systems strongly dependent on the size of the system. • Number of emerging magnetic monopoles, in the phase of magnetic reversal, depend of the aspect. • Different systems can be created based on this idea, for information technology.

  13. Quantum dynamics of crystals of molecular magnets inside microwave resonators

    Energy Technology Data Exchange (ETDEWEB)

    Amigo, R.; Tejada, J.; Chudnovsky, E.M.; Hernandez, J.M.; Garcia-Santiago, A. E-mail: antonio@ubxlab.comtoni@ubxlab.com

    2004-05-01

    It is shown that crystals of molecular nanomagnets exhibit enhanced magnetic relaxation when placed inside a resonant cavity. Strong dependence of the magnetization curve on the geometry of the cavity has been observed, providing evidence of the coherent microwave radiation by the crystals. These observations open the possibility of building a nanomagnetic microwave laser pumped by the magnetic field.

  14. Quantum dynamics of crystals of molecular magnets inside microwave resonators

    International Nuclear Information System (INIS)

    Amigo, R.; Tejada, J.; Chudnovsky, E.M.; Hernandez, J.M.; Garcia-Santiago, A.

    2004-01-01

    It is shown that crystals of molecular nanomagnets exhibit enhanced magnetic relaxation when placed inside a resonant cavity. Strong dependence of the magnetization curve on the geometry of the cavity has been observed, providing evidence of the coherent microwave radiation by the crystals. These observations open the possibility of building a nanomagnetic microwave laser pumped by the magnetic field

  15. Reliability analysis of magnetic logic interconnect wire subjected to magnet edge imperfections

    Science.gov (United States)

    Zhang, Bin; Yang, Xiaokuo; Liu, Jiahao; Li, Weiwei; Xu, Jie

    2018-02-01

    Nanomagnet logic (NML) devices have been proposed as one of the best candidates for the next generation of integrated circuits thanks to its substantial advantages of nonvolatility, radiation hardening and potentially low power. In this article, errors of nanomagnetic interconnect wire subjected to magnet edge imperfections have been evaluated for the purpose of reliable logic propagation. The missing corner defects of nanomagnet in the wire are modeled with a triangle, and the interconnect fabricated with various magnetic materials is thoroughly investigated by micromagnetic simulations under different corner defect amplitudes and device spacings. The results show that as the defect amplitude increases, the success rate of logic propagation in the interconnect decreases. More results show that from the interconnect wire fabricated with materials, iron demonstrates the best defect tolerance ability among three representative and frequently used NML materials, also logic transmission errors can be mitigated by adjusting spacing between nanomagnets. These findings can provide key technical guides for designing reliable interconnects. Project supported by the National Natural Science Foundation of China (No. 61302022) and the Scientific Research Foundation for Postdoctor of Air Force Engineering University (Nos. 2015BSKYQD03, 2016KYMZ06).

  16. Spin and Charge Transport in 2D Materials and Magnetic Insulator/Metal Heterostructures

    Science.gov (United States)

    Amamou, Walid

    Spintronic devices are very promising for future information storage, logic operations and computation and have the potential to replace current CMOS technology approaching the scaling limit. In particular, the generation and manipulation of spin current enables the integration of storage and logic within the same circuit for more powerful computing architectures. In this thesis, we examine the manipulation of spins in 2D materials such as graphene and metal/magnetic insulator heterostructures. In particular, we investigate the feasibility for achieving magnetization switching of a nanomagnet using graphene as a nonmagnetic channel material for All Spin Logic Device applications. Using in-situ MBE deposition of nanomagnet on graphene spin valve, we demonstrate the presence of an interfacial spin dephasing at the interface between the graphene and the nanomagnet. By introducing a Cu spacer between the nanomagnet and graphene, we demonstrate that this interfacial effect is related to an exchange interaction between the spin current and the disordered magnetic moment of the nanomagnet in the first monolayer. In addition to the newly discovered interfacial spin relaxation effect, the extracted contact resistance area product of the nanomagnet/graphene interface is relatively high on the order of 1Omicrom2. In practice, reducing the contact resistance will be as important as eliminating the interfacial relaxation in order to achieve magnetization switching. Furthermore, we examine spin manipulation in a nonmagnetic Pt using an internal magnetic exchange field produced by the adjacent magnetic insulator CoFe2O4 grown by MBE. Here, we report the observation of a strong magnetic proximity effect of Pt deposited on top of a perpendicular magnetic anisotropy (PMA) inverse spinel material Cobalt Ferrite (CFO, CoFe 2O4). The CFO was grown by MBE and its magnetization was characterized by Vibrating Sample Magnetometry (VSM) demonstrating the strong out of plane magnetic

  17. Imaging magnetic domains in Ni nanostructures

    International Nuclear Information System (INIS)

    Asenjo, A.; Jaafar, M.; Gonzalez, E.M.; Martin, J.I.; Vazquez, M.; Vicent, J.L.

    2007-01-01

    The study of nanomagnets is the subject of increasing scientific effort. The size, the thickness and the geometric shape of the elements determine the magnetic properties and then the domain configuration. In this work, we fabricated by electron-beam lithography the three different arrays of Ni nanostructures keeping the size, the thickness and also the distance constant between the elements but varying the geometry: square, triangular and circular. The domain structure of the nanomagnets is studied by magnetic force microscopy

  18. Vector spin modeling for magnetic tunnel junctions with voltage dependent effects

    International Nuclear Information System (INIS)

    Manipatruni, Sasikanth; Nikonov, Dmitri E.; Young, Ian A.

    2014-01-01

    Integration and co-design of CMOS and spin transfer devices requires accurate vector spin conduction modeling of magnetic tunnel junction (MTJ) devices. A physically realistic model of the MTJ should comprehend the spin torque dynamics of nanomagnet interacting with an injected vector spin current and the voltage dependent spin torque. Vector spin modeling allows for calculation of 3 component spin currents and potentials along with the charge currents/potentials in non-collinear magnetic systems. Here, we show 4-component vector spin conduction modeling of magnetic tunnel junction devices coupled with spin transfer torque in the nanomagnet. Nanomagnet dynamics, voltage dependent spin transport, and thermal noise are comprehended in a self-consistent fashion. We show comparison of the model with experimental magnetoresistance (MR) of MTJs and voltage degradation of MR with voltage. Proposed model enables MTJ circuit design that comprehends voltage dependent spin torque effects, switching error rates, spin degradation, and back hopping effects

  19. Material Targets for Scaling All-Spin Logic

    Science.gov (United States)

    Manipatruni, Sasikanth; Nikonov, Dmitri E.; Young, Ian A.

    2016-01-01

    All-spin-logic devices are promising candidates to augment and complement beyond-CMOS integrated circuit computing due to nonvolatility, ultralow operating voltages, higher logical efficiency, and high density integration. However, the path to reach lower energy-delay product performance compared to CMOS transistors currently is not clear. We show that scaling and engineering the nanoscale magnetic materials and interfaces is the key to realizing spin-logic devices that can surpass the energy-delay performance of CMOS transistors. With validated stochastic nanomagnetic and vector spin-transport numerical models, we derive the target material and interface properties for the nanomagnets and channels. We identify promising directions for material engineering and discovery focusing on the systematic scaling of magnetic anisotropy (Hk ) and saturation magnetization (Ms ), the use of perpendicular magnetic anisotropy, and the interface spin-mixing conductance of the ferromagnet-spin-channel interface (Gmix ). We provide systematic targets for scaling a spin-logic energy-delay product toward 2 aJ ns, comprehending the stochastic noise for nanomagnets.

  20. Instantons and magnetization tunneling: Beyond the giant-spin approximation

    International Nuclear Information System (INIS)

    Florez, J.M.; Vargas, P.; Nunez, Alvaro S.

    2009-01-01

    In this work we show that commonly neglected fluctuations of the net total spin of a molecular nanomagnet strongly modified its tunneling properties and provide a scenario to explain some discrepancies between theory and experiment. Starting off from an effective spin Hamiltonian, we study the quantum tunneling of the magnetization of molecular nanomagnets in the regime where the giant-spin approximation is breaking down. This study is done using an instanton description of the tunneling path. The instanton is calculated considering its coupling to quantum fluctuations.

  1. Extensive degeneracy, Coulomb phase and magnetic monopoles in artificial square ice.

    Science.gov (United States)

    Perrin, Yann; Canals, Benjamin; Rougemaille, Nicolas

    2016-12-15

    Artificial spin-ice systems are lithographically patterned arrangements of interacting magnetic nanostructures that were introduced as way of investigating the effects of geometric frustration in a controlled manner. This approach has enabled unconventional states of matter to be visualized directly in real space, and has triggered research at the frontier between nanomagnetism, statistical thermodynamics and condensed matter physics. Despite efforts to create an artificial realization of the square-ice model-a two-dimensional geometrically frustrated spin-ice system defined on a square lattice-no simple geometry based on arrays of nanomagnets has successfully captured the macroscopically degenerate ground-state manifold of the model. Instead, square lattices of nanomagnets are characterized by a magnetically ordered ground state that consists of local loop configurations with alternating chirality. Here we show that all of the characteristics of the square-ice model are observed in an artificial square-ice system that consists of two sublattices of nanomagnets that are vertically separated by a small distance. The spin configurations we image after demagnetizing our arrays reveal unambiguous signatures of a Coulomb phase and algebraic spin-spin correlations, which are characterized by the presence of 'pinch' points in the associated magnetic structure factor. Local excitations-the classical analogues of magnetic monopoles-are free to evolve in an extensively degenerate, divergence-free vacuum. We thus provide a protocol that could be used to investigate collective magnetic phenomena, including Coulomb phases and the physics of ice-like materials.

  2. Generic mechanisms of decoherence of quantum oscillations in magnetic double-well systems

    International Nuclear Information System (INIS)

    Chudnovsky, Eugene M.

    2004-01-01

    Fundamental conservation laws mandate parameter-free generic mechanisms of decoherence of quantum oscillations in double-well systems. We consider two examples: tunneling of the magnetic moment in nanomagnets and tunneling between macroscopic current states in SQUIDs. In both cases the decoherence occurs via emission of phonons and photons at the oscillation frequency. We also show that in a system of identical qubits the decoherence greatly increases due to the superradiance of electromagnetic and sound waves. Our findings have important implications for building elements of quantum computers based upon nanomagnets and SQUIDs

  3. Generic mechanisms of decoherence of quantum oscillations in magnetic double-well systems

    Energy Technology Data Exchange (ETDEWEB)

    Chudnovsky, Eugene M. E-mail: chudnov@lehman.cuny.edu

    2004-05-01

    Fundamental conservation laws mandate parameter-free generic mechanisms of decoherence of quantum oscillations in double-well systems. We consider two examples: tunneling of the magnetic moment in nanomagnets and tunneling between macroscopic current states in SQUIDs. In both cases the decoherence occurs via emission of phonons and photons at the oscillation frequency. We also show that in a system of identical qubits the decoherence greatly increases due to the superradiance of electromagnetic and sound waves. Our findings have important implications for building elements of quantum computers based upon nanomagnets and SQUIDs.

  4. Mechanisms of antibacterial activity and stability of silver ...

    Indian Academy of Sciences (India)

    using scanning electron microscopy revealed that the size and surface density of AgNPs grown by the photoreduc- tion of silver ... doped TiO2 nanosheet films against S. aureus and E. coli in the dark .... Zeiss) with an attached Axiovert 200M (Zeiss) inverted flu- ... SEM imaging of TiO2 and AgNPs/TiO2 coatings as well as.

  5. Molecules as nanomagnets

    Energy Technology Data Exchange (ETDEWEB)

    Caneschi, A.; Gatteschi, D.; Sessoli, R. [Florence Univ. (Italy). Dep. di Chimica

    1998-12-01

    The design and the synthesis of molecular clusters which give rise to slow relaxation of the magnetization at low temperature are the focus of a great interdisciplinary interest, because they provide unique materials to test the theories of quantum tunneling of the magnetization. A short review is provided here of the best systems so far discovered, outlining the possible relevance of this new class of materials to future applications. [Italiano] La progettazione e la sintesi di cluster molecolari che danno luogo a rilassamento lento della magnetizzazione a bassa temperatura sono oggetto di un grande interesse interdisciplinare, perche` sono materiali unici per mettere alla prova le teorie sugli effetti quantistici che si possono osservare in sintesi macroscopici. In questo articolo vengono brevemente passati in rassegna i migliori sistemi fin qui scoperti e vengono date alcune indicazioni per la possibile importanza di questa nuova classe di materiali per applicazioni future.

  6. Molecules as nanomagnets

    International Nuclear Information System (INIS)

    Caneschi, A.; Gatteschi, D.; Sessoli, R.

    1998-01-01

    The design and the synthesis of molecular clusters which give rise to slow relaxation of the magnetization at low temperature are the focus of a great interdisciplinary interest, because they provide unique materials to test the theories of quantum tunneling of the magnetization. A short review is provided here of the best systems so far discovered, outlining the possible relevance of this new class of materials to future applications [it

  7. Nanomagnetics with lasers

    Indian Academy of Sciences (India)

    Wintec

    scopic property such as magnetization, which is a conse- quence of the cooperative ..... cally with film thickness, and if the bulk lattice parameter of the structure that is ... superconducting quantum interference device based mag- netometer.

  8. The Oviduct and Serous Cancer Risk Assessment

    Science.gov (United States)

    2016-10-01

    genes deregulated in putative stem cells (Yamamoto et al) has been made public. Page 4 What was the impact on society beyond science and...Interline CCD camera and NIS-Elements Advanced Research v.4.13 software (Nikon, Japan) or an LSM 780 confocal microscope (Carl Zeiss, Germany ) with LSM...Carl Zeiss, Germany ) and each selected cell population from different slides of the same patient was pooled. Total RNAs were extracted using the Pico

  9. Preclinical Validation of Anti-Nuclear Factor Kappa B Therapy against Vestibular Schwannoma and Neurofibromatosis Type II

    Science.gov (United States)

    2015-06-01

    Thomsen, J., Nielsen, F.C., 2010. Deregulated genes in sporadic vestibular schwannomas. Otol. Neurotol. 31 (2), 256e266. Cioffi, J.A., Yue, W.Y., Mendolia...Thomas, R., Gope, M.L., Doddaballapur, S.K., Gope, R., 2006. Age dependent phosphorylation and deregulation of p53 in human vestibular schwannomas. Mol...tissue was visualized and imaged using a Carl Zeiss 2000 upright microscope (Carl Zeiss, Jena, Germany ). Schwann and schwannoma cell isolation and

  10. Shapiro like steps reveals molecular nanomagnets’ spin dynamics

    International Nuclear Information System (INIS)

    Abdollahipour, Babak; Abouie, Jahanfar; Ebrahimi, Navid

    2015-01-01

    We present an accurate way to detect spin dynamics of a nutating molecular nanomagnet by inserting it in a tunnel Josephson junction and studying the current voltage (I-V) characteristic. The spin nutation of the molecular nanomagnet is generated by applying two circularly polarized magnetic fields. We demonstrate that modulation of the Josephson current by the nutation of the molecular nanomagnet’s spin appears as a stepwise structure like Shapiro steps in the I-V characteristic of the junction. Width and heights of these Shapiro-like steps are determined by two parameters of the spin nutation, frequency and amplitude of the nutation, which are simply tuned by the applied magnetic fields

  11. Safety implications of high-field MRI: actuation of endogenous magnetic iron oxides in the human body.

    Directory of Open Access Journals (Sweden)

    Jon Dobson

    Full Text Available Magnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla are becoming increasingly common. In light of recent European Union moves to limit high-field exposure for those working with MRI scanners, we have evaluated the potential for detrimental cellular effects via nanomagnetic actuation of endogenous iron oxides in the body.Theoretical models and experimental data on the composition and magnetic properties of endogenous iron oxides in human tissue were used to analyze the forces on iron oxide particles.Results show that, even at 9.4 Tesla, forces on these particles are unlikely to disrupt normal cellular function via nanomagnetic actuation.

  12. Magnetic Molecules from Chemist's Point of View

    Science.gov (United States)

    Hendrickson, David

    2002-03-01

    A single-molecule magnet (SMM) is a molecule that functions as a nanoscale, single-domain magnetic particle that, below its blocking temperature, exhibits magnetization hysteresis [1]. SMMs have attracted considerable interest because they : (1) can serve as the smallest nanomagnet, monodisperse in size, shape and anisotropy; (2) exhibit quantum tunneling of magnetization (QTM); and (3) may function as memory devices in a quantum computer. SMM’s are synthetically designed nanomagnets, built from a core containing metal ion unpaired spin carriers bridged by oxide or other simple ions which is surrounded by organic ligands. Many systematic changes can be made in the structure of these molecular nanomagnets. Manganese-containing SMM’s are known with from Mn4 to Mn_30 compositions. The magnetic bistability, which is desirable for data storage applications, is achievable at temperatures below 3K. The largest spin of the ground state of a SMM is presently S = 13. Appreciable largely uniaxial magnetoanisotropy in the ground state leads to magnetic bistability. Rather than a continuum of higher energy states separating the “spin-up” and “spin-down” ground states, the quantum nature of the molecular nanomagnets result in a well defined ladder of discrete quantum states. Recent studies have definitively shown that, under conditions that can be controlled via the application of external perturbations, quantum tunneling may occur through the energy separating the “spin-up” and “spin-down” states. The tunneling is due to weak symmetry breaking perturbations that give rise to long-lived quantum states consisting of coherent superpositions of the “spin-up” and “spin-down” states. It is the ability to manipulate these coherent states that makes SMMs particularly attractive for quantum computation. Reference: [1] G. Christou, D. Gatteschi, D. N. Hendrickson, R. Sessoli, “Single-molecule Magnets”, M.R.S. Bull. 25, 66 (2001).

  13. Prototyping of Microfluidic Systems with Integrated Waveguides in Cyclin Olefin Copolymer

    DEFF Research Database (Denmark)

    Bundgaard, Frederik

    2007-01-01

    , in a collaboration with IMTEK in Freiburg, Germany, an optical detection principle was developed. Using the principle of total internal reflection of a laser beam incident on a fluidic channel, detection of air bubbles is possible. The principle was used on a rotating platform as well as on non-moving systems....... the substrate, optical layers and the lid in the microfluidic systems. • Thermal bonding of polymer structures, including roll lamination of foil onto substrates. • Laser bonding of two polymer layers, including transparent on black, and transparent on transparent with a particle doped spin coating. • Thermal...... treatment of waveguides to improve the surface roughness and lower the propagation loss. The fabrication methods have been characterised, and have been optimised to minimise parameters like fabrication time, surface roughness and interface bonding strength. Using these fabrication methods, microfluidic...

  14. CTC-Endothelial Cell Interactions during Metastasis

    Science.gov (United States)

    2014-06-01

    equipped with a Zeiss AxioCam MRm camera . A syringe pump (KDS 230, IITC Life Science, Woodland Hills, CA) was used to control the shear stress of the...HUVECs in 2 ml growth medium at 180 x g for 5 min. Measure the cell concentration using a neubauer hemocytometer and prepare 107 HUVEC cells/100 µl...selectin (R&D Systems, Minneapolis, MN). Coated microtubes were mounted on an inverted microscope equipped with a Zeiss AxioCam MRm camera . A syringe pump

  15. Electrical manipulation of dynamic magnetic impurity and spin texture of helical Dirac fermions

    Science.gov (United States)

    Wang, Rui-Qiang; Zhong, Min; Zheng, Shi-Han; Yang, Mou; Wang, Guang-Hui

    2016-05-01

    We have theoretically investigated the spin inelastic scattering of helical electrons off a high-spin nanomagnet absorbed on a topological surface. The nanomagnet is treated as a dynamic quantum spin and driven by the spin transfer torque effect. We proposed a mechanism to electrically manipulate the spin texture of helical Dirac fermions rather than by an external magnetic field. By tuning the bias voltage and the direction of impurity magnetization, we present rich patterns of spin texture, from which important fingerprints exclusively associated with the spin helical feature are obtained. Furthermore, it is found that the nonmagnetic potential can create the resonance state in the spin density with different physics as the previously reported resonance of charge density.

  16. Mixed hemimicelles solid-phase extraction based on sodium dodecyl sulfate-coated nano-magnets for selective adsorption and enrichment of illegal cationic dyes in food matrices prior to high-performance liquid chromatography-diode array detection detection.

    Science.gov (United States)

    Qi, Ping; Liang, Zhi-An; Wang, Yu; Xiao, Jian; Liu, Jia; Zhou, Qing-Qiong; Zheng, Chun-Hao; Luo, Li-Ni; Lin, Zi-Hao; Zhu, Fang; Zhang, Xue-Wu

    2016-03-11

    In this study, mixed hemimicelles solid-phase extraction (MHSPE) based on sodium dodecyl sulfate (SDS) coated nano-magnets Fe3O4 was investigated as a novel method for the extraction and separation of four banned cationic dyes, Auramine O, Rhodamine B, Basic orange 21 and Basic orange 22, in condiments prior to HPLC detection. The main factors affecting the extraction of analysts, such as pH, surfactant and adsorbent concentrations and zeta potential were studied and optimized. Under optimized conditions, the proposed method was successful applied for the analysis of banned cationic dyes in food samples such as chili sauce, soybean paste and tomato sauce. Validation data showed the good recoveries in the range of 70.1-104.5%, with relative standard deviations less than 15%. The method limits of determination/quantification were in the range of 0.2-0.9 and 0.7-3μgkg(-1), respectively. The selective adsorption and enrichment of cationic dyes were achieved by the synergistic effects of hydrophobic interactions and electrostatic attraction between mixed hemimicelles and the cationic dyes, which also resulted in the removal of natural pigments interferences from sample extracts. When applied to real samples, RB was detected in several positive samples (chili powders) within the range from 0.042 to 0.177mgkg(-1). These results indicate that magnetic MHSPE is an efficient and selective sample preparation technique for the extraction of banned cationic dyes in a complex matrix. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Nanomodulation of molecular nanomagnets.

    Science.gov (United States)

    Feng, Patrick L; Koo, Changhyun; Henderson, John J; Manning, Paul; Nakano, Motohiro; del Barco, Enrique; Hill, Stephen; Hendrickson, David N

    2009-04-20

    Detailed synthetic, structural, and magnetic characterizations for a family of six [Mn(3)Zn(2)](13+) complexes are presented. These complexes have planar [Mn(3)(III)-(mu(3)-oxo)](7+) core magnetic units and have formulas represented by [cation](3)[Mn(3)Zn(2)(R-salox)(3)O(N(3))(6)X(2)], where [cation](+) = [NEt(4)](3)(+) or [AsPh(4)](3)(+); R = H or Me; and X = Cl(-), Br(-), I(-), or N(3)(-). Least-squares fits to the magnetic susceptibility data for these complexes indicate large negative values of the axial zero field splitting (ZFS) parameter D (approximately -1.1 K) and spin ground states ranging from a highly spin-mixed S approximately 1 to a reasonably isolated S = 6 (DeltaE(S = 5) = 69.2 K). The strength and magnitude of the intramolecular exchange interactions have been observed to change with the crystal packing as a result of systematic variations in the co-crystallizing cation, terminal ion, and oximate ligand. Alternating current susceptibility data were collected from 1.8-7 K at 10-997 Hz, revealing strong frequency-dependent peaks in the out-of-phase susceptibility (chi''(M)) for ferromagnetic S = 6 complexes 1, 2, and 6. Fitting of these data to the Arrhenius equation gave U(eff) = 44.0 K and tau(0) = 3.8 x 10(-8) s for [NEt(4)](3)[Mn(3)Zn(2)(salox)(3)O(N(3))(6)Cl(2)] (1), and U(eff) = 45.6 K and tau(0) = 2.1 x 10(-7) s for [NEt(4)](3)[Mn(3)Zn(2)(Me-salox)(3)O(N(3))(6)Cl(2)] (6). The enhanced relaxation behavior in complex 6 is associated with stronger ferromagnetic exchange interactions and a more isolated S = 6 ground state than in 1 and 2. Comprehensive high-frequency electron paramagnetic resonance (HFEPR) experiments were conducted on single crystals of complexes 1, 2, and 6, revealing sharp absorption peaks and allowing for the precise determination of ZFS parameters. Similar experiments on [AsPh(4)](3)[Mn(3)Zn(2)(salox)(3)O(N(3))(6)Cl(2)] (4) resulted in the observation of a broad absorption peak, consistent with the highly spin-mixed ground state. Single crystal magnetization hysteresis measurements on complexes 1 and 2 indicate SMM behavior via temperature- and sweep-rate dependent hysteresis loops and the observance of very sharp quantum tunneling resonances. Additionally, the Hamiltonian parameters derived from the magnetic data, HFEPR, and hysteresis measurements are in good agreement and highlight the relationships between superexchange, spin-orbit interactions, and the varied relaxation behavior in these complexes.

  18. The Nuclear Spin Nanomagnet

    OpenAIRE

    Korenev, V. L.

    2007-01-01

    Linearly polarized light tuned slightly below the optical transition of the negatively charged exciton (trion) in a single quantum dot causes the spontaneous nuclear spin polarization (self-polarization) at a level close to 100%. The effective magnetic field of spin-polarized nuclei brings the optical transition energy into resonance with photon energy. The resonantly enhanced Overhauser effect sustains the stability of the nuclear self-polarization even in the absence of spin polarization of...

  19. Evaluation of actual vs expected photodynamic therapy spot size.

    Science.gov (United States)

    Ranchod, Tushar M; Brucker, Alexander J; Liu, Chengcheng; Cukras, Catherine A; Hopkins, Tim B; Ying, Gui-Shuang

    2009-05-01

    To determine the accuracy of the photodynamic therapy (PDT) laser spot size on the retina as generated by 2 Food and Drug Administration (FDA)-approved lasers. Prospective observational case series. Fundus photographs were taken of 1 eye of each of 10 subjects with the WinStation 4000 fundus photography system (OIS; Ophthalmic Imaging Systems, Sacramento, California, USA); disc size was calculated using OIS software. Slit-lamp photographs were taken of the PDT laser spot focused on the retina adjacent to the optic disc, using various spot sizes in combination with 3 different contact lenses and 2 different lasers. Spot size at the retina was determined by measuring the ratio of disc diameter to spot diameter in Adobe Photoshop (San Jose, California, USA) and applying this ratio to the OIS disc measurements. Spot size at the retina averaged 87% of expected spot size for the Coherent Opal laser (Coherent Inc, Santa Clara, California, USA) and 104% of expected spot size for the Zeiss Visulas laser (Carl Zeiss Meditec Inc, Dublin, California, USA)(P = .002). Multivariate analysis demonstrated that percentage of expected spot size decreased with larger spot diameter (P = .01 for Coherent laser; P = .02 for Zeiss laser). PDT spot size at the retina appears to be consistently smaller than expected for the Coherent laser while the spot size was consistently within 10% of expected size for the Zeiss laser. The deviation from expected size increased with larger spot size using the Coherent laser.

  20. Microscopic Origin of Interfacial Dzyaloshinskii-Moriya Interaction

    KAUST Repository

    Kim, Sanghoon; Ueda, Kohei; Go, Gyungchoon; Jang, Peong-Hwa; Lee, Kyung-Jin; Belabbes, Abderrezak; Manchon, Aurelien; Suzuki, Motohiro; Kotani, Yoshinori; Nakamura, Tetsuya; Nakamura, Kohji; Koyama, Tomohiro; Chiba, Daichi; Yamada, Kihiro; Kim, Duck-Ho; Moriyama, Takahiro; Kim, Kab-Jin; Ono, Teruo

    2017-01-01

    Chiral spin textures at the interface between ferromagnetic and heavy nonmagnetic metals, such as Neel-type domain walls and skyrmions, have been studied intensively because of their great potential for future nanomagnetic devices

  1. Magnetic polyoxometalates: from molecular magnetism to molecular spintronics and quantum computing.

    Science.gov (United States)

    Clemente-Juan, Juan M; Coronado, Eugenio; Gaita-Ariño, Alejandro

    2012-11-21

    In this review we discuss the relevance of polyoxometalate (POM) chemistry to provide model objects in molecular magnetism. We present several potential applications in nanomagnetism, in particular, in molecular spintronics and quantum computing.

  2. Profiling and quantitative evaluation of three Nickel-Coated magnetic matrices for purification of recombinant proteins: lelpful hints for the optimized nanomagnetisable matrix preparation

    Directory of Open Access Journals (Sweden)

    Zarei Saeed

    2011-08-01

    Full Text Available Abstract Background Several materials are available in the market that work on the principle of protein magnetic fishing by their histidine (His tags. Little information is available on their performance and it is often quoted that greatly improved purification of histidine-tagged proteins from crude extracts could be achieved. While some commercial magnetic matrices could be used successfully for purification of several His-tagged proteins, there are some which have been proved to operate just for a few extent of His-tagged proteins. Here, we address quantitative evaluation of three commercially available Nickel nanomagnetic beads for purification of two His-tagged proteins expressed in Escherichia coli and present helpful hints for optimized purification of such proteins and preparation of nanomagnetisable matrices. Results Marked differences in the performance of nanomagnetic matrices, principally on the basis of their specific binding capacity, recovery profile, the amount of imidazole needed for protein elution and the extent of target protein loss and purity were obtained. Based on the aforesaid criteria, one of these materials featured the best purification results (SiMAG/N-NTA/Nickel for both proteins at the concentration of 4 mg/ml, while the other two (SiMAC-Nickel and SiMAG/CS-NTA/Nickel did not work well with respect to specific binding capacity and recovery profile. Conclusions Taken together, functionality of different types of nanomagnetic matrices vary considerably. This variability may not only be dependent upon the structure and surface chemistry of the matrix which in turn determine the affinity of interaction, but, is also influenced to a lesser extent by the physical properties of the protein itself. Although the results of the present study may not be fully applied for all nanomagnetic matrices, but provide a framework which could be used to profiling and quantitative evaluation of other magnetisable matrices and also

  3. Gratings for synchrotron and FEL beamlines: a project for the manufacture of ultra-precise gratings at Helmholtz Zentrum Berlin.

    Science.gov (United States)

    Siewert, F; Löchel, B; Buchheim, J; Eggenstein, F; Firsov, A; Gwalt, G; Kutz, O; Lemke, St; Nelles, B; Rudolph, I; Schäfers, F; Seliger, T; Senf, F; Sokolov, A; Waberski, Ch; Wolf, J; Zeschke, T; Zizak, I; Follath, R; Arnold, T; Frost, F; Pietag, F; Erko, A

    2018-01-01

    Blazed gratings are of dedicated interest for the monochromatization of synchrotron radiation when a high photon flux is required, such as, for example, in resonant inelastic X-ray scattering experiments or when the use of laminar gratings is excluded due to too high flux densities and expected damage, for example at free-electron laser beamlines. Their availability became a bottleneck since the decommissioning of the grating manufacture facility at Carl Zeiss in Oberkochen. To resolve this situation a new technological laboratory was established at the Helmholtz Zentrum Berlin, including instrumentation from Carl Zeiss. Besides the upgraded ZEISS equipment, an advanced grating production line has been developed, including a new ultra-precise ruling machine, ion etching technology as well as laser interference lithography. While the old ZEISS ruling machine GTM-6 allows ruling for a grating length up to 170 mm, the new GTM-24 will have the capacity for 600 mm (24 inch) gratings with groove densities between 50 lines mm -1 and 1200 lines mm -1 . A new ion etching machine with a scanning radiofrequency excited ion beam (HF) source allows gratings to be etched into substrates of up to 500 mm length. For a final at-wavelength characterization, a new reflectometer at a new Optics beamline at the BESSY-II storage ring is under operation. This paper reports on the status of the grating fabrication, the measured quality of fabricated items by ex situ and in situ metrology, and future development goals.

  4. Bulk magnetic properties of CdFe2 O4 in nano-regime

    Indian Academy of Sciences (India)

    TECS

    In recent years, the design and synthesis of nano-magnetic particles ... 1998). Two different types of spin structure were suggested .... rule integration of the pseudo-Voigt function. ... differences between measured and calculated values) that.

  5. Separating read and write units in multiferroic devices.

    Science.gov (United States)

    Roy, Kuntal

    2015-06-18

    Strain-mediated multiferroic composites, i.e., piezoelectric-magnetostrictive heterostructures, hold profound promise for energy-efficient computing in beyond Moore's law era. While reading a bit of information stored in the magnetostrictive nanomagnets using a magnetic tunnel junction (MTJ), a material selection issue crops up since magnetostrictive materials in general cannot be utilized as the free layer of the MTJ. This is an important issue since we need to achieve a high magnetoresistance for technological applications. We show here that magnetically coupling the magnetostrictive nanomagnet and the free layer e.g., utilizing the magnetic dipole coupling between them can circumvent this issue. By solving stochastic Landau-Lifshitz-Gilbert equation of magnetization dynamics in the presence of room-temperature thermal fluctuations, we show that such design can eventually lead to a superior energy-delay product.

  6. Systems of imaging digital systems in case of glaucoma

    International Nuclear Information System (INIS)

    Fernandez Argones, Liamet; Piloto Diaz, Ibrain; Coba Penna, Maria Josefa; Perez Tamayo, Bertila; Dominguez Randulfe, Marerneda; Trujillo Fonseca, Katia

    2009-01-01

    Now a day we can't consider the strict follow up in Glaucoma without the use of the digital analysis of image system of the optic nerve head and the retinal nerve fiber layer. This is a review about some contributions of Scanning Laser Polarimetry (GDx VCC, Carl Zeiss Meditec, Dublin, CA), Confocal Scanning Laser (Heidelberg Retina Tomograph HRT, Heidelberg Engineering Inc.) and Optical Coherence Tomography (Stratus OCT, Carl Zeiss Meditec, Alemania) in the diagnosis and follow up of Glaucoma. It's considered that objective measurement giving by them must be incorporate in the rigorous analysis of each glaucomatous patient

  7. Use of optical microscopes in research work in the field of work safety in mines

    Energy Technology Data Exchange (ETDEWEB)

    Piskorska-Kalisz, Z

    1979-05-01

    Notes that coal dust in mine air is measured by means of optical microscopes. The microscope is part of a dust counter called a konimeter. With the help of optical microscopes dust particles in a sample are counted. The Cawood-Patterson network is inserted in the eyepiece of a microscope. At present konimeters produced by Zeiss Works are used in Poland. In predicting rock burst hazard microscopes (light reflecting system) are used, e.g. Zeiss microscope Ng. With its help microcracks in coal samples are counted. An optical stereoscopic microscope is used for calculating the range of flames during coal dust explosions.

  8. Correlation of the Dzyaloshinskii–Moriya interaction with Heisenberg exchange and orbital asphericity

    KAUST Repository

    Kim, Sanghoon; Ueda, Kohei; Go, Gyungchoon; Jang, Peong-Hwa; Lee, Kyung-Jin; Belabbes, Abderrezak; Manchon, Aurelien; Suzuki, Motohiro; Kotani, Yoshinori; Nakamura, Tetsuya; Nakamura, Kohji; Koyama, Tomohiro; Chiba, Daichi; Yamada, Kihiro. T.; Kim, Duck-Ho; Moriyama, Takahiro; Kim, Kab-Jin; Ono, Teruo

    2018-01-01

    Chiral spin textures of a ferromagnetic layer in contact to a heavy non-magnetic metal, such as Néel-type domain walls and skyrmions, have been studied intensively because of their potential for future nanomagnetic devices. The Dyzaloshinskii

  9. Lateral spin transfer torque induced magnetic switching at room temperature demonstrated by x-ray microscopy

    Science.gov (United States)

    Buhl, M.; Erbe, A.; Grebing, J.; Wintz, S.; Raabe, J.; Fassbender, J.

    2013-10-01

    Changing and detecting the orientation of nanomagnetic structures, which can be used for durable information storage, needs to be developed towards true nanoscale dimensions for keeping up the miniaturization speed of modern nanoelectronic components. Therefore, new concepts for controlling the state of nanomagnets are currently in the focus of research in the field of nanoelectronics. Here, we demonstrate reproducible switching of a purely metallic nanopillar placed on a lead that conducts a spin-polarized current at room temperature. Spin diffusion across the metal-metal (Cu to CoFe) interface between the pillar and the lead causes spin accumulation in the pillar, which may then be used to set the magnetic orientation of the pillar. In our experiments, the detection of the magnetic state of the nanopillar is performed by direct imaging via scanning transmission x-ray microscopy (STXM).

  10. Quantum chemical study of regular and irregular geometries of MgO nanoclusters : Effects on magnetizability, electronic properties and physical characteristics

    NARCIS (Netherlands)

    Manzetti, Sergio; Yakovlev, Alexei

    2017-01-01

    Advanced materials and surfaces are key components in nanotechnology and are applied by their magnetizable and spintronic properties, high-frequency scattering, and properties attributing to nanoelectronics and nanomagnetic components. Earth oxides are a group of materials with catalytic effects in

  11. Selective Adsorption of Uranium (VI) on NaHCO 3 Leached ...

    African Journals Online (AJOL)

    Ion imprinted nano-magnetic composite polymers for selective removal of hexavalent uranium were prepared by a precipitation polymerization technique in the presence of γ-methacryloxypropyltrimethoxysilane (γ-MPS) coated magnetite and other pre-polymerization reagents. The synthesized magnetic polymers were then ...

  12. Pramana – Journal of Physics | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    This review summarizes recent experimental investigations using neutron scattering on layered nanomagnetic systems (accentuating my contribution), which have applications in spintronics also. Polarized neutron investigations of such artificially structured materials are basically done to understand the interplay between ...

  13. Molecular nanomagnets and related phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Song (ed.) [Peking Univ., Beijing (China). College of Chemistry and Molecular Engineering

    2015-07-01

    The series Structure and Bonding publishes critical reviews on topics of research concerned with chemical structure and bonding. The scope of the series spans the entire Periodic Table and addresses structure and bonding issues associated with all of the elements. It also focuses attention on new and developing areas of modern structural and theoretical chemistry such as nanostructures, molecular electronics, designed molecular solids, surfaces, metal clusters and supramolecular structures. Physical and spectroscopic techniques used to determine, examine and model structures fall within the purview of Structure and Bonding to the extent that the focus is on the scientific results obtained and not on specialist information concerning the techniques themselves. Issues associated with the development of bonding models and generalizations that illuminate the reactivity pathways and rates of chemical processes are also relevant. The individual volumes in the series are thematic. The goal of each volume is to give the reader, whether at a university or in industry, a comprehensive overview of an area where new insights are emerging that are of interest to a larger scientific audience. Thus each review within the volume critically surveys one aspect of that topic and places it within the context of the volume as a whole. The most significant developments of the last 5 to 10 years should be presented using selected examples to illustrate the principles discussed. A description of the physical basis of the experimental techniques that have been used to provide the primary data may also be appropriate, if it has not been covered in detail elsewhere. The coverage need not be exhaustive in data, but should rather be conceptual, concentrating on the new principles being developed that will allow the reader, who is not a specialist in the area covered, to understand the data presented. Discussion of possible future research directions in the area is welcomed. Review articles for the individual volumes are invited by the volume editors. Readership: research scientists at universities or in industry, graduate students Special offer for all customers who have a standing order to the print version of Structure and Bonding, we offer free access to the electronic volumes of the Series published in the current year via SpringerLink.

  14. Molecular nanomagnets and related phenomena

    International Nuclear Information System (INIS)

    Gao, Song

    2015-01-01

    The series Structure and Bonding publishes critical reviews on topics of research concerned with chemical structure and bonding. The scope of the series spans the entire Periodic Table and addresses structure and bonding issues associated with all of the elements. It also focuses attention on new and developing areas of modern structural and theoretical chemistry such as nanostructures, molecular electronics, designed molecular solids, surfaces, metal clusters and supramolecular structures. Physical and spectroscopic techniques used to determine, examine and model structures fall within the purview of Structure and Bonding to the extent that the focus is on the scientific results obtained and not on specialist information concerning the techniques themselves. Issues associated with the development of bonding models and generalizations that illuminate the reactivity pathways and rates of chemical processes are also relevant. The individual volumes in the series are thematic. The goal of each volume is to give the reader, whether at a university or in industry, a comprehensive overview of an area where new insights are emerging that are of interest to a larger scientific audience. Thus each review within the volume critically surveys one aspect of that topic and places it within the context of the volume as a whole. The most significant developments of the last 5 to 10 years should be presented using selected examples to illustrate the principles discussed. A description of the physical basis of the experimental techniques that have been used to provide the primary data may also be appropriate, if it has not been covered in detail elsewhere. The coverage need not be exhaustive in data, but should rather be conceptual, concentrating on the new principles being developed that will allow the reader, who is not a specialist in the area covered, to understand the data presented. Discussion of possible future research directions in the area is welcomed. Review articles for the individual volumes are invited by the volume editors. Readership: research scientists at universities or in industry, graduate students Special offer for all customers who have a standing order to the print version of Structure and Bonding, we offer free access to the electronic volumes of the Series published in the current year via SpringerLink.

  15. Quantum Properties of Molecular Nanomagnets

    Science.gov (United States)

    2017-08-28

    Emilia) Italy. Prof. Stephen Hill, Florida State University and National High Magnetic Field Laboratory (USA) Prof. Takeji Takui, Osaka City University...November 2016 Prof. Stephen Hill visited our laboratory in Modena PRESENTATION AT INTERNATIONAL CONFERENCES AND MEETINGS. M. Affronte: 2016... Stephen ; Vitorica-Yrezabal, Inigo; Timco, Grigore; Winpenny, Richard; Affronte, Marco J. Phys. Chem. Lett., 2015, 6 (24), pp 5062–5066 DOI: 10.1021

  16. NMR study of the molecular nanomagnet [Fe8(N3C6H15)6O2(OH)12]·[Br8·9H2O] in the high-spin magnetic ground state

    International Nuclear Information System (INIS)

    Furukawa, Y.; Kumagai, K.; Lascialfari, A.; Aldrovandi, S.; Borsa, F.; Sessoli, R.; Gatteschi, D.

    2001-01-01

    The magnetic molecular cluster [Fe 8 (N 3 C 6 H 15 ) 6 O 2 (OH) 12 ] 8+ [Br 8 ·9H 2 O] 8- , in short Fe8, has been investigated at low temperature by 1 H-NMR and relaxation measurements. Some measurements of 2 D-NMR in partially deuterated Fe8 clusters will also be reported. Upon decreasing temperature the NMR spectra display a very broad and structured signal which is the result of the internal local fields at the proton sites due to the local moments of the Fe(III) ions in the total S=10 magnetic ground state. The proton and deuteron NMR spectra have been analyzed and the different resonance peaks have been attributed to the different proton groups in the molecule. The simulation of the spectra by using a dipolar hyperfine field and the accepted model for the orientation of the Fe(III) local moments do not agree with the experiments even when the magnitude of the local Fe(III) moments is allowed to vary. It is concluded that a positive contact hyperfine interaction of the same order of magnitude as the dipolar interaction is present for all proton sites except the water molecules. The temperature and magnetic field dependence of the nuclear spin-lattice relaxation rate is ascribed to the fluctuations of the local Fe(III) moments, which follow rigidly the fluctuations of the total ground state magnetization of the nanomagnet. By using a simple model already utilized for the Mn12 cluster, we derive the value of the spin phonon coupling constant which determines the lifetime broadening of the different magnetic quantum number m substates of the S=10 ground state. It is shown that the lifetime broadening decreases rapidly on lowering the temperature. When the lifetime becomes longer than the reciprocal of the frequency shift of the proton lines a structure emerges in the NMR spectrum reflecting the ''frozen'' local moment configuration

  17. Ferromagnetic nanostructures by laser manipulation

    NARCIS (Netherlands)

    Bosch, R.C.M.

    2002-01-01

    Lithography based on laser focusing of a beam of neutral iron atoms shows great promise for creating nanomagnetic structures. Laser focusing is a relatively new area, where successful experiments have been performed with, e.g., chromium atoms. Iron is perhaps one of the most difficult elements for

  18. Emergent reduced dimensionality by vertex frustration in artificial spin ice

    Science.gov (United States)

    Gilbert, Ian; Lao, Yuyang; Carrasquillo, Isaac; O'Brien, Liam; Watts, Justin D.; Manno, Michael; Leighton, Chris; Scholl, Andreas; Nisoli, Cristiano; Schiffer, Peter

    2016-02-01

    Reducing the dimensionality of a physical system can have a profound effect on its properties, as in the ordering of low-dimensional magnetic materials, phonon dispersion in mercury chain salts, sliding phases, and the electronic states of graphene. Here we explore the emergence of quasi-one-dimensional behaviour in two-dimensional artificial spin ice, a class of lithographically fabricated nanomagnet arrays used to study geometrical frustration. We extend the implementation of artificial spin ice by fabricating a new array geometry, the so-called tetris lattice. We demonstrate that the ground state of the tetris lattice consists of alternating ordered and disordered bands of nanomagnetic moments. The disordered bands can be mapped onto an emergent thermal one-dimensional Ising model. Furthermore, we show that the level of degeneracy associated with these bands dictates the susceptibility of island moments to thermally induced reversals, thus establishing that vertex frustration can reduce the relevant dimensionality of physical behaviour in a magnetic system.

  19. Thermally induced magnetic relaxation in square artificial spin ice

    Science.gov (United States)

    Andersson, M. S.; Pappas, S. D.; Stopfel, H.; Östman, E.; Stein, A.; Nordblad, P.; Mathieu, R.; Hjörvarsson, B.; Kapaklis, V.

    2016-11-01

    The properties of natural and artificial assemblies of interacting elements, ranging from Quarks to Galaxies, are at the heart of Physics. The collective response and dynamics of such assemblies are dictated by the intrinsic dynamical properties of the building blocks, the nature of their interactions and topological constraints. Here we report on the relaxation dynamics of the magnetization of artificial assemblies of mesoscopic spins. In our model nano-magnetic system - square artificial spin ice - we are able to control the geometrical arrangement and interaction strength between the magnetically interacting building blocks by means of nano-lithography. Using time resolved magnetometry we show that the relaxation process can be described using the Kohlrausch law and that the extracted temperature dependent relaxation times of the assemblies follow the Vogel-Fulcher law. The results provide insight into the relaxation dynamics of mesoscopic nano-magnetic model systems, with adjustable energy and time scales, and demonstrates that these can serve as an ideal playground for the studies of collective dynamics and relaxations.

  20. Out-of-plane and in-plane magnetization behavior of dipolar interacting FeNi nanoislands around the percolation threshold

    Czech Academy of Sciences Publication Activity Database

    Stupakov, Alexandr; Bagdinov, A.V.; Prokhorov, V.V.; Bagdinova, A.N.; Demikhov, E.I.; Dejneka, Alexandr; Kugel, K.I.; Gorbatsevich, A.A.; Pudonin, F.A.; Kovaleva, Natalia

    2016-01-01

    Roč. 2016, Oct (2016), s. 1-9, č. článku 3190260. ISSN 1687-4110 R&D Projects: GA ČR GA15-13778S Institutional support: RVO:68378271 Keywords : FeNi nanoisland * nanomagnetism Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.871, year: 2016

  1. Dialkylamide as Both Capping Agent and Surfactant in a Direct Solvothermal Synthesis of Magnetite and Titania Nanoparticles

    Czech Academy of Sciences Publication Activity Database

    Cara, C.; Musinu, A.; Mameli, V.; Ardu, A.; Nižňanský, D.; Buršík, Josef; Scorciapino, M. A.; Manzo, G.; Cannas, C.

    2015-01-01

    Roč. 15, č. 5 (2015), s. 2364-2372 ISSN 1528-7483 R&D Projects: GA ČR(CZ) GA14-18392S Institutional support: RVO:61388980 Keywords : Nanomagnetics * Nanoparticles * Nuclear magnetic resonance * Fourier transform infrared spectroscopy Subject RIV: CA - Inorganic Chemistry Impact factor: 4.425, year: 2015

  2. Quercetin - A Flavonoid Compound from Sarcopyramis bodinieri var ...

    African Journals Online (AJOL)

    The flavonoid compound was identified as quercetin by 1H-. NMR and ESI-MS ... phenolic compounds were isolated, and their .... scored under a fluorescence microscope (Carl. Zeiss .... Antioxidant Properties of Sarcopyramis bodinieri.

  3. Further development of the instrument and technique for photometric evaluation of autoradiograms

    Energy Technology Data Exchange (ETDEWEB)

    Freyer, K; Baumbach, H; Birkholz, W; Kiese, H J [Akademie der Wissenschaften der DDR, Leipzig. Zentralinstitut fuer Isotopen- und Strahlenforschung

    1976-01-01

    Analogous and digital techniques for evaluation of autoradiograms are compared and measured for critical evaluation of autoradiograms. Additional instruments to a Zeiss-Photometer for digital and analogous evaluation of autoradiograms are described.

  4. Low temperature synthesis of nanosized Mn1–xZnxFe2O4 ferrites ...

    Indian Academy of Sciences (India)

    Administrator

    spectrum analysis were carried out to confirm the spinel phase formation as well as to ascertain the cation distri- bution in the ferrite ... structured materials technology opening up in the last few ... recent years, the design and synthesis of nano-magnetic particles ..... complex system like the ferrites where many cations are.

  5. Molecular nanomagnets: the first 10 years

    International Nuclear Information System (INIS)

    Gatteschi, Dante; Sessoli, Roberta

    2004-01-01

    We review here the main achievements reached in the field of magnetic molecules in the first 10 years of activity. After introducing the concept of magnetic molecules we report at some length on the archetypal Mn12Ac, pointing out what is understood and what is still left to do. Other systems will also be reported including Fe8 and Mn4. A section will be devoted to magnetic chains and a final section will give perspectives for future developments

  6. Spin Tunneling in a Rotating Nanomagnet

    Science.gov (United States)

    O'Keeffe, Michael; Chudnovsky, Eugene; Lehman College Theoretical Condensed Matter Physics Team

    2011-03-01

    We study spin tunneling in a magnetic nanoparticle with biaxial anisotropy that is free to rotate about its anisotropy axis. Exact instanton of the coupled equations of motion is found that connects degenerate classical energy minima. We show that mechanical freedom of the particle renormalizes magnetic anisotropy and increases the tunnel splitting. M. F. O'Keeffe and E. M. Chudnovsky, cond-mat, arXiv:1011.3134.

  7. Molecular nanomagnets: the first 10 years

    Energy Technology Data Exchange (ETDEWEB)

    Gatteschi, Dante E-mail: dante.gatteschi@unifi.it; Sessoli, Roberta

    2004-05-01

    We review here the main achievements reached in the field of magnetic molecules in the first 10 years of activity. After introducing the concept of magnetic molecules we report at some length on the archetypal Mn12Ac, pointing out what is understood and what is still left to do. Other systems will also be reported including Fe8 and Mn4. A section will be devoted to magnetic chains and a final section will give perspectives for future developments.

  8. Archaeological applications of naturally occurring nanomagnets

    Energy Technology Data Exchange (ETDEWEB)

    Linford, Neil [English Heritage, Fort Cumberland, Fort Cumberland Road, Eastney, Portsmouth PO4 9LD (United Kingdom)

    2005-01-01

    The ubiquitous presence of iron minerals within the soils and sediments forming archaeological sites can often provide a valuable record of past human activity. These records are formed through the alteration of weakly magnetic minerals to fine grained iron oxides, such as magnetite or maghaemite, that leave an almost indelible magnetic 'finger print' on the landscape. Archaeologists have exploited these magnetic records at a variety of levels from geophysical survey to reveal the location of a site, to determining how old a particular excavated feature may be through archaeomagnetic dating. More recent studies have investigated the process of magnetic enhancement through the often complex interaction of pedogenic, microbial and anthropogenic mechanisms and pathways. This research has revealed many unique magnetic signatures within archaeological sediments that may help to identify a range of significant environmental conditions, such as the effects of climate change or the deliberate use of fire. This paper aims to provide an overview of how the techniques of environmental magnetism may be applied to the analysis of archaeological remains. Both field based geophysical prospecting and the measurement of magnetic properties from samples recovered during excavation will be considered. The interpretation of the resulting magnetic measurements will also be addressed through the use of an unmixing algorithm applied to hysteresis data.

  9. Archaeological applications of naturally occurring nanomagnets

    International Nuclear Information System (INIS)

    Linford, Neil

    2005-01-01

    The ubiquitous presence of iron minerals within the soils and sediments forming archaeological sites can often provide a valuable record of past human activity. These records are formed through the alteration of weakly magnetic minerals to fine grained iron oxides, such as magnetite or maghaemite, that leave an almost indelible magnetic 'finger print' on the landscape. Archaeologists have exploited these magnetic records at a variety of levels from geophysical survey to reveal the location of a site, to determining how old a particular excavated feature may be through archaeomagnetic dating. More recent studies have investigated the process of magnetic enhancement through the often complex interaction of pedogenic, microbial and anthropogenic mechanisms and pathways. This research has revealed many unique magnetic signatures within archaeological sediments that may help to identify a range of significant environmental conditions, such as the effects of climate change or the deliberate use of fire. This paper aims to provide an overview of how the techniques of environmental magnetism may be applied to the analysis of archaeological remains. Both field based geophysical prospecting and the measurement of magnetic properties from samples recovered during excavation will be considered. The interpretation of the resulting magnetic measurements will also be addressed through the use of an unmixing algorithm applied to hysteresis data

  10. Childhood Eye Diseases in Bayelsa State, Nigeria: A Tertiary Eye ...

    African Journals Online (AJOL)

    -Streit) and a posterior segement examination using a direct and indirect ophthalmoscopes (KeelerR) as necessary. Those requiring refraction was sent to the optometrist. Objective refraction was done using a Carl Zeiss 599 autorefractometer ...

  11. Morning Glory Disc Anomaly: A Case Report

    African Journals Online (AJOL)

    Ocular complications in affected eye may include strabismus, retinal detachment and reduced visual acuity. Contralateral ... near acuity was OD J3 and OS J1+ according to Jaeger. ... Using the Automated Humphrey Field analyser (Carl Zeiss.

  12. Effect of nanocrystalline surface of substrate on microstructure and ...

    Indian Academy of Sciences (India)

    surface layers or bulk nanocrystalline metals and alloys more effectively. ... severe plastic deformation on surface layers of bulk met- als at high strains and strain rates. .... scanning electron microscopy (SEM) (Zeiss, model: Sigma. VP), energy ...

  13. Anisotropy evolution of nanoparticles under annealing: Benefits of isothermal remanent magnetization simulation

    Science.gov (United States)

    Tournus, Florent; Tamion, Alexandre; Hillion, Arnaud; Dupuis, Véronique

    2016-12-01

    Isothermal remanent magnetization (IRM) combined with Direct current demagnetization (DcD) are powerful tools to qualitatively study the interactions (through the Δm parameter) between magnetic particles in a granular media. For magnetic nanoparticles diluted in a matrix, it is possible to reach a regime where Δm is equal to zero, i.e. where interparticle interactions are negligible: one can then infer the intrinsic properties of nanoparticles through measurements on an assembly, which are analyzed by a combined fit procedure (based on the Stoner-Wohlfarth and Néel models). Here we illustrate the benefits of a quantitative analysis of IRM curves, for Co nanoparticles embedded in amorphous carbon (before and after annealing): while a large anisotropy increase may have been deduced from the other measurements, IRM curves provide an improved characterization of the nanomagnets intrinsic properties, revealing that it is in fact not the case. This shows that IRM curves, which only probe the irreversible switching of nanomagnets, are complementary to widely used low field susceptibility curves.

  14. Anisotropy evolution of nanoparticles under annealing: Benefits of isothermal remanent magnetization simulation

    International Nuclear Information System (INIS)

    Tournus, Florent; Tamion, Alexandre; Hillion, Arnaud; Dupuis, Véronique

    2016-01-01

    Isothermal remanent magnetization (IRM) combined with Direct current demagnetization (DcD) are powerful tools to qualitatively study the interactions (through the Δm parameter) between magnetic particles in a granular media. For magnetic nanoparticles diluted in a matrix, it is possible to reach a regime where Δm is equal to zero, i.e. where interparticle interactions are negligible: one can then infer the intrinsic properties of nanoparticles through measurements on an assembly, which are analyzed by a combined fit procedure (based on the Stoner–Wohlfarth and Néel models). Here we illustrate the benefits of a quantitative analysis of IRM curves, for Co nanoparticles embedded in amorphous carbon (before and after annealing): while a large anisotropy increase may have been deduced from the other measurements, IRM curves provide an improved characterization of the nanomagnets intrinsic properties, revealing that it is in fact not the case. This shows that IRM curves, which only probe the irreversible switching of nanomagnets, are complementary to widely used low field susceptibility curves.

  15. Anisotropy evolution of nanoparticles under annealing: Benefits of isothermal remanent magnetization simulation

    Energy Technology Data Exchange (ETDEWEB)

    Tournus, Florent, E-mail: florent.tournus@univ-lyon1.fr; Tamion, Alexandre; Hillion, Arnaud; Dupuis, Véronique

    2016-12-01

    Isothermal remanent magnetization (IRM) combined with Direct current demagnetization (DcD) are powerful tools to qualitatively study the interactions (through the Δm parameter) between magnetic particles in a granular media. For magnetic nanoparticles diluted in a matrix, it is possible to reach a regime where Δm is equal to zero, i.e. where interparticle interactions are negligible: one can then infer the intrinsic properties of nanoparticles through measurements on an assembly, which are analyzed by a combined fit procedure (based on the Stoner–Wohlfarth and Néel models). Here we illustrate the benefits of a quantitative analysis of IRM curves, for Co nanoparticles embedded in amorphous carbon (before and after annealing): while a large anisotropy increase may have been deduced from the other measurements, IRM curves provide an improved characterization of the nanomagnets intrinsic properties, revealing that it is in fact not the case. This shows that IRM curves, which only probe the irreversible switching of nanomagnets, are complementary to widely used low field susceptibility curves.

  16. Nematoda: Dorylaimida

    African Journals Online (AJOL)

    1992-04-02

    sedimenta- tion method (Loubser 1985), killed by gentle heat, fixed in. FAA, processed into glycerine by Thome's slow method and mounted on permanent slides. Measurements and draw- ings were made with the aid of a Zeiss ...

  17. Micrometer and CCD measurements of double stars (Series 51

    Directory of Open Access Journals (Sweden)

    Popović G.M.

    1998-01-01

    Full Text Available 36 micrometric measurements of 20 double or multiple systems carried out with the Zeiss 65/1055 cm Refractor of Belgrade Observatory are communicated. Also 35 CCD measurements of 15 double or multiple systems are included.

  18. The potential of postharvest silicon dips to regulate phenolics in ...

    African Journals Online (AJOL)

    ACCI

    2013-03-27

    Mar 27, 2013 ... This study investigated the ability of silicon dips to enhance the phenolic content in order to .... observed under a scanning electron microscope equipped with. EDX detector (Zeiss EVO LS15, Oxford XMax detector, and INCA.

  19. Clean Energy for the Commonwealth Powered by UMass

    Science.gov (United States)

    2009-04-15

    Nanomagnetics Zeolite membranes Polymer-inorganic nanocomposites MEMS Nanostructured catalysts Plant Biotechnology Biochem., Cell wall struct., Agronomy Crambe...power management Low-power device networks Energy scavenging Flame Modeling Combustion chemistry Molecular-beam mass spectrometry Building Design...Thayumanavan, PhD. UMass Amherst Professor of Chemistry and Director, Fueling the Future Center for Chemical Innovation – Paul Osenar, PhD. Chief

  20. Contrasting magnetism in dilute and supersaturated cobalt-fullerene mixture films

    Czech Academy of Sciences Publication Activity Database

    Lavrentiev, Vasyl; Stupakov, Alexandr; Pokorný, Jan; Lavrentieva, Inna; Vacík, Jiří; Dejneka, Alexandr; Barchuk, M.; Čapková, P.

    2015-01-01

    Roč. 48, č. 33 (2015), s. 335002 ISSN 0022-3727 R&D Projects: GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:68378271 ; RVO:61389005 Keywords : cobalt * fullerene * nanomagnetism * nanostructure * self-organization Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders; BM - Solid Matter Physics ; Magnetism (FZU-D) Impact factor: 2.772, year: 2015

  1. Installation of a technological center for highly efficient optical gratings at Helmholtz-Zentrum Berlin (HZB)

    International Nuclear Information System (INIS)

    Loechel, B; Erko, A; Lemke, St; Senf, F; Nelles, B; Schmidt, M

    2013-01-01

    In 2009 Carl Zeiss stopped the manufacture of precision gratings. All users of their gratings were very concerned about this decision, since they all need precision gratings for their experiments. One of the institutes of the HZB, the Institute for Nanometer Optics and Technology (INT), has extensive experience in micro fabrication (technology group). In spring 2010, HZB decided to take over the old C. Zeiss grating fabrication and build up its own technology center for grating fabrication. In March 2010, the INT applied to the Senate of Berlin for funding for our project from the European Regional Development Fund (ERDF). In October 2010, HZB received an approval of its application from the Senate of Berlin (contract No 20072013 2/43). Using this governmental support, HZB will install all necessary equipment and processes to fulfill these demands until end of 2013.

  2. Whither a "National Planetarium"?

    Science.gov (United States)

    DeVorkin, David

    2018-01-01

    In Spring 1927 Zeiss contacted the Smithsonian Institution about its new wonderful planetarium projector, sending along brochures and testimonials from astronomers. By the end of the year after much back and forth, Zeiss even found backers to underwrite the planetarium for the Smithsonian, feeling that the first planetarium should be built in Washington. Over the following decades, the push for a “national planetarium” revived several times, as a possible option for Jefferson’s Memorial or as a commercial enterprise to revitalize the southwest quadrant of the city. It was even the topic for a student essay contest. Nothing caught on, though planetariums soon proved to be wildly popular in the cities that nurtured them. Here I’ll outline the efforts for Washington, D.C. and ask what the campaigns reveal about the perception of astronomy on the National Mall.

  3. Optimization and validation of a method for the determination of the refractive index of milk serum based on the reaction between milk and copper(II) sulfate to detect milk dilutions.

    Science.gov (United States)

    Rezende, Patrícia Sueli; Carmo, Geraldo Paulo do; Esteves, Eduardo Gonçalves

    2015-06-01

    We report the use of a method to determine the refractive index of copper(II) serum (RICS) in milk as a tool to detect the fraudulent addition of water. This practice is highly profitable, unlawful, and difficult to deter. The method was optimized and validated and is simple, fast and robust. The optimized method yielded statistically equivalent results compared to the reference method with an accuracy of 0.4% and quadrupled analytical throughput. Trueness, precision (repeatability and intermediate precision) and ruggedness are determined to be satisfactory at a 95.45% confidence level. The expanded uncertainty of the measurement was ±0.38°Zeiss at the 95.45% confidence level (k=3.30), corresponding to 1.03% of the minimum measurement expected in adequate samples (>37.00°Zeiss). Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Association between physical and geochemical characteristics of ...

    African Journals Online (AJOL)

    Algae were identified with a Carl Zeiss inverted light microscope (magnification of 400 or 1 000). Sub- samples were taken until no new species .... An interesting picture that emerges from Table 2 is that certain algae are confined to specific ...

  5. Hydrothermal Synthesis of NiFe2O4 nano-particles: Structural ...

    Indian Academy of Sciences (India)

    10

    Cole plots are drawn to study electrical conduction mechanism and the kind of ... Zeiss), Transmission Electron Microscope (TEM: Model Tecnai G20, FEI, USA), JASCO ...... Z' Vs. Z" plot (Nyquist plot) of NiFe2O4 at room temperature (RT).

  6. Macular volume and central foveal thickness measurements in ...

    African Journals Online (AJOL)

    Objective: To determine macular volume and central foveal thickness measurements in normal eyes of healthy. Nigerian adults using Stratus optical coherence tomography. Subjects and Methods: Consenting 100 adults Nigerians with normal eyes were recruited and examined using Carl. Zeiss Stratus Optical Coherence ...

  7. Journal of Astrophysics and Astronomy | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... Keywords. Telescopes; method: observational; stars: oscillation. Abstract. The Maidanak One-meter Telescope (MOT) is a Ritchey-Chretien telescope by Carl Zeiss, located atop Maidanak in Uzbekistan, where site parameters indicate excellent atmospheric seeing conditions. An effort to computerize the ...

  8. Small Incision Lenticule Extraction (SMILE) vs. Femtosecond Laser in Situ Keratomileusis (FS-LASIK) for treatment of myopia

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Justesen, Birgitte

    Purpose: - 67 ord LASIK has been the dominating corneal refractive procedure for almost two decades, but the new flap-free SMILE procedure has shown promising results. The aim of this study was to evaluate and compare refractive predictability, uncorrected and corrected distance visual acuity (UDVA...... and CDVA), and safety at 1 day, 1 week and 3 months after SMILE and FS-LASIK for all degrees of myopia, but in particular high myopia. Setting: Department of Ophthalmology, Odense University Hospital, Odense, Denmark Methods: - 157 ord Retrospective study of results after SMILE and FS-LASIK for all degrees...... having undergone re-treatment. The SMILE treatments and FS-LASIK flaps were performed with a VisuMax® femtosecond laser (Carl Zeiss-Meditec, Jena, Germany). The FS-LASIK photoablation was performed with a MEL-80 flying-spot excimer laser with eye-tracker (Carl Zeiss-Meditec, Jena, Germany). In SMILE...

  9. The response of microalgal biomass and community composition to ...

    African Journals Online (AJOL)

    2011-06-06

    Jun 6, 2011 ... Estuary (33º 43' S; 25º 51' E), and is permanently open to the sea (Fig. 1). .... visualised using the Imaplan V 2.06 image analysis programme. (IMATEC ... using the Zeiss IM 35 inverted microscope at 630x magnifica- tion.

  10. A new rhodamine based 'turn-on' ion selective chemosensor in ...

    Indian Academy of Sciences (India)

    ABHISHEK MAJI

    2017-08-03

    Aug 3, 2017 ... working under a physiological condition with a fast response is highly .... fluorescence microscope (Carl Zeiss, Germany) using an oil immersion lens at 63X ... mg/mL PBS) was added to each well of a 96-well culture plate and ...

  11. The Replication Stress Response in Pancreatic Cancer

    Science.gov (United States)

    2014-12-01

    both causes cell death. We hypothesize that novel RSR genes maintain genome integrity and that deregulation of RSR genes and their cancer barrier...Microscopy, Jena, Germany ) microscope with Axiovision Rei 4.8 software (Zeiss, Jena. Germany ) using the x 63 oil objective. Foci quantitation was

  12. Dual Beam System (SEM/FIB) Equipment for the Kleberg Advanced Microscopy Center

    Science.gov (United States)

    2015-06-05

    PRODUCT, INCLUDING SPECIFICALLY, BUT WITHOUT LIMITATION, LIABILITY FOR NEGLIGENCE OR STRICT LIABILITY IN TORT . NOTWITHSTANDING ANY OTHER PROVISION OF THIS...CONTRACT OR TORT ) TO BUYER OR ANY OTHER PERSON FOR ANY PUNITIVE, SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WITH RESPECT TO ZEISS’S OBLIGATIONS HEREUNDER

  13. Anisotropic magnetization of Fe8 molecular nanomagnet

    International Nuclear Information System (INIS)

    Ueda, Miki; Maegawa, Satoru

    2002-01-01

    The magnetization of the single crystal of a molecular magnet [(C 6 H 15 N 3 ) 6 Fe 8 O 2 (OH) 12 ] Br 7 (H 2 O) Br·8H 2 O, Fe8, has been measured in the temperature down to 1.8 K and the field up to 5 T. The molecule Fe8 consists of eight Fe 3+ ions with spins s=5/2. The magnetization at low temperatures shows large anisotropy depending on the orientation of the external magnetic field. The temperature and magnetic field dependences of the magnetization are well explained by the Hamiltonian for the isolated molecules with total spins S=10. The anisotropies of D and E are estimated to be -0.276 K and -0.035 K, respectively. (author)

  14. Vortex jump behavior in coupled nanomagnetic heterostructures

    International Nuclear Information System (INIS)

    Zhang, S.; Phatak, C.; Petford-Long, A. K.; Heinonen, O.

    2014-01-01

    The spin configuration and magnetic behavior in patterned nanostructures can be controlled by manipulating the interplay between the competing energy terms. This in turn requires fundamental knowledge of the magnetic interactions at the local nanometer scale. Here, we report on the spin structure and magnetization behavior of patterned discs containing exchange coupled ferromagnetic layers with additional exchange bias to an antiferromagnetic layer. The magnetization reversal was explored by direct local visualization of the domain behavior using in-situ Lorentz transmission electron microscopy, from which quantitative magnetic induction maps were reconstructed. The roles of the main competing energy terms were elucidated and the reversal mechanism was identified as a coupled phenomenon of incoherent rotation in the exchange-biased layer and localized vortex nucleation and discontinuous propagation in the free layer, including an anomalous jump in the trajectory. The observations were supported by micromagnetic simulations and modeled phase shift simulations. The work presented here provides fundamental insights into opportunities for macroscopic control of the energy landscape of magnetic heterostructures for functional applications

  15. Ultrathin magnetic structures IV applications of nanomagnetism

    CERN Document Server

    Heinrich, Bretislav

    2004-01-01

    The ability to understand and control the unique properties of interfaces has created an entirely new field of magnetism which already has a profound impact in technology and is providing the basis for a revolution in electronics. The last decade has seen dramatic progress in the development of magnetic devices for information technology but also in the basic understanding of the physics of magnetic nanostructures. Volume III describes thin film magnetic properties and methods for characterising thin film structure topics that underpin the present 'spintronics' revolution in which devices are based on combined magnetic materials and semiconductors. The present volume (IV) deals with the fundamentals of spintronics: magnetoelectronic materials, spin injection and detection, micromagnetics and the development of magnetic random access memory based on GMR and tunnel junction devices. Together these books provide readers with a comprehensive account of an exciting and rapidly developing field. The treatment is de...

  16. Ultrathin magnetic structures III fundamentals of nanomagnetism

    CERN Document Server

    Bland, JAC

    2004-01-01

    The ability to understand and control the unique properties of interfaces has created an entirely new field of magnetism which already has a profound impact in technology and is providing the basis for a revolution in electronics. The last decade has seen dramatic progress in the development of magnetic devices for information technology but also in the basic understanding of the physics of magnetic nanostructures. This volume describes thin film magnetic properties and methods for characterising thin film structure topics that underpin the present 'spintronics' revolution in which devices are based on combined magnetic materials and semiconductors. Volume IV deals with the fundamentals of spintronics: magnetoelectronic materials, spin injection and detection, micromagnetics and the development of magnetic random access memory based on GMR and tunnel junction devices. Together these books provide readers with a comprehensive account of an exciting and rapidly developing field. The treatment is designed to be ...

  17. Vortex jump behavior in coupled nanomagnetic heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, S.; Phatak, C., E-mail: cd@anl.gov [Materials Science Division, Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, Illinois 60439 (United States); Petford-Long, A. K. [Materials Science Division, Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, Illinois 60439 (United States); Department of Materials Science and Engineering, Northwestern University, 2220 Campus Drive, Evanston, Illinois 60208 (United States); Heinonen, O. [Materials Science Division, Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, Illinois 60439 (United States); Department of Physics and Astronomy, Northwestern University, 2145 Sheridan Rd, Evanston, Illinois 60208-3112 (United States)

    2014-11-24

    The spin configuration and magnetic behavior in patterned nanostructures can be controlled by manipulating the interplay between the competing energy terms. This in turn requires fundamental knowledge of the magnetic interactions at the local nanometer scale. Here, we report on the spin structure and magnetization behavior of patterned discs containing exchange coupled ferromagnetic layers with additional exchange bias to an antiferromagnetic layer. The magnetization reversal was explored by direct local visualization of the domain behavior using in-situ Lorentz transmission electron microscopy, from which quantitative magnetic induction maps were reconstructed. The roles of the main competing energy terms were elucidated and the reversal mechanism was identified as a coupled phenomenon of incoherent rotation in the exchange-biased layer and localized vortex nucleation and discontinuous propagation in the free layer, including an anomalous jump in the trajectory. The observations were supported by micromagnetic simulations and modeled phase shift simulations. The work presented here provides fundamental insights into opportunities for macroscopic control of the energy landscape of magnetic heterostructures for functional applications.

  18. Molecular nanomagnetism in actinide-based coordination complexes

    International Nuclear Information System (INIS)

    Caciuffo, R.; Colineau; Magnani, N.; Santini, G.; Amoretti, S.; Carretta, P.; Mougel, J.; Pécaut, L.; Chatelain, S.; Gambarelli, J.; Hermle, M.; Mazzanti, V.; Degeyer, A.; Tuna, E.F.

    2014-01-01

    We present very recent results obtained for a hetero-metallic U(V)-Mn(II) one-dimensional chain assembled through cation-cation interactions , and for a triangular molecule containing three U(V)O2+ (5f1) ions . The former is the first example of an actinidecontaining single-chain magnet (SCM), with a relaxation barrier of 134 K, a blocking temperature of 6 K, and an impressive coercive field Bc = 3.4 tesla at 2 K. The latter is characterized by a non-magnetic ground doublet corresponding to two oppositely twisted chiral arrangements of the U moments, and (in presence of a magnetic field orthogonal to the triangle plane) by quantum tunnelling of the noncollinear magnetization accompanied by oscillations of the anapole (toroidal) moment

  19. Symposium I: Nanoscale Magnetic Materials and Applications. Held in Boston, Massachusetts on November 25-30, 2007

    Science.gov (United States)

    2008-06-01

    on anodized aluminum oxide ( AAO ) templates[1,2] with further tailored nano-magnet configurations will also be discussed. For evaluation of ultra...North Carolina State University, Raleigh, North Carolina. Unlike other nanoporous membranes , nanoporous alumina (also known as anodized aluminum oxide ... oxide ( AAO ) membrane is used as the template with gallium indium (Gain) as a seed layer. After fabrication, the nanowires are removed from the template

  20. Nanofluidic Pre-Concentration Devices for Enhancing the Detection Sensitivity and Selectivity of Biomarkers for Human Performance Monitoring

    Science.gov (United States)

    2012-12-01

    approximately 1.5 V/cm field strength. The preconcentration of fluorescently labeled strep- tavidin protein samples (52.8 kDa, Molecular Probes, Engene , OR, USA...Molecular Probes, Engene , OR) or ~50 nm silica nanoparticles (Corpuscular Inc., Cold Spring, NY) using an inverted microscope (Zeiss Observer A1

  1. Heating ability and biocompatibility study of silica-coated magnetic ...

    Indian Academy of Sciences (India)

    systems, MNPs are normally coated with a thermosensitive polymer ... and dispersed in water alkalized by adding some drops of ammonia ... The morphology and particle size distribution of nanoparti- cles were examined using a Zeiss-EM10C transmission elec- tron microscope (TEM) operated at an acceleration voltage.

  2. Newly designed, simple relief phase contrast for microscopy of microorganisms

    Czech Academy of Sciences Publication Activity Database

    Žižka, Zdeněk

    2010-01-01

    Roč. 55, č. 6 (2010), s. 662-665 ISSN 0015-5632 R&D Projects: GA MŠk LC06066 Institutional research plan: CEZ:AV0Z50200510 Keywords : optical microscopy * Zeiss NG 10/1 * microphotography Subject RIV: EE - Microbiology, Virology Impact factor: 0.977, year: 2010

  3. Objective detection of apoptosis in rat renal tissue sections using light microscopy and free image analysis software with subsequent machine learning: Detection of apoptosis in renal tissue.

    Science.gov (United States)

    Macedo, Nayana Damiani; Buzin, Aline Rodrigues; de Araujo, Isabela Bastos Binotti Abreu; Nogueira, Breno Valentim; de Andrade, Tadeu Uggere; Endringer, Denise Coutinho; Lenz, Dominik

    2017-02-01

    The current study proposes an automated machine learning approach for the quantification of cells in cell death pathways according to DNA fragmentation. A total of 17 images of kidney histological slide samples from male Wistar rats were used. The slides were photographed using an Axio Zeiss Vert.A1 microscope with a 40x objective lens coupled with an Axio Cam MRC Zeiss camera and Zen 2012 software. The images were analyzed using CellProfiler (version 2.1.1) and CellProfiler Analyst open-source software. Out of the 10,378 objects, 4970 (47,9%) were identified as TUNEL positive, and 5408 (52,1%) were identified as TUNEL negative. On average, the sensitivity and specificity values of the machine learning approach were 0.80 and 0.77, respectively. Image cytometry provides a quantitative analytical alternative to the more traditional qualitative methods more commonly used in studies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Combined anti-tumor therapeutic effect of targeted gene, hyperthermia, radionuclide brachytherapy in breast carcinoma

    International Nuclear Information System (INIS)

    Chen Daozhen; Tang Qiusha; Xiang Jingying; Xu Fei; Zhang Li; Wang Junfeng

    2011-01-01

    Objective: To investigate the antitumor therapeutic effect of combined therapy of magnetic induction heating by nano-magnetic particles, herpes simplex virus thymidine kinase gene (HSV-tk suicide gene) and internal radiation in mice bearing MCF-7 breast carcinoma. Methods: The transfection reagents, plasmids heat shock protein-HSV-tk (pHSP-HSV-tk), ferroso-ferric oxide nano-magnetic fluid flow and 188 Re-ganciclovir-bovine serum albumin-nanopaticles (GCV-BSA-NP) were prepared. The heating experiments in vivo were carried out using ferroso-ferric oxide nano-magnetic fluid flow. Sixty mice tumor models bearing MCF-7 breast carcinoma were established and randomly divided into six groups. Group A was the control group, B was gene transfection therapy group, C was hyperthermia group, D was gene transfection therapy combined with radionuclide brachytherapy group, E was gene therapy combined with hyperthermia group, and F was gene therapy, hyperthermia combined with radionuclide brachytherapy group. The tumor growth, tumor mass and histopathological changes were evaluated. The expression of HSV-tk in the groups of B, D, E and F was detected by RT-PCR. Poisson distribution and one-way analysis of variance (ANOVA) were used for statistical analysis by SPSS 10.0 software. Results: In the animal heating experiments, the temperature of tumor increased up to 39.6 degree C, 43.2 degree C, and 48.1 degree C quickly with different injected doses (2, 4 and 6 mg respectively) of nano-magnetic particles and maintained for 40 min. The temperature of tumor tissue reduced to 36.8 degree C, 37.5 degree C and 37.8 degree C in 10 min when alternating magnetic field (AMF) stopped. The tumor mass in Groups C ((452.50±30.29) mg), D ((240.98±35.32)mg), E((231.87±27.41) mg) and F ((141.55±23.78) mg) were much lower than that in Group A ((719.12±22.65) mg) (F=800.07, P<0.01), with the most significant treatment effect in Group F.The tumor mass in Group B((684.05±24.02) mg) was higher than

  5. CIRCLE Enhancement After Myopic SMILE.

    Science.gov (United States)

    Siedlecki, Jakob; Luft, Nikolaus; Mayer, Wolfgang J; Siedlecki, Martin; Kook, Daniel; Meyer, Bertram; Bechmann, Martin; Wiltfang, Rainer; Priglinger, Siegfried G; Dirisamer, Martin

    2018-05-01

    To report the outcomes of enhancement after small incision lenticule extraction (SMILE) using the VisuMax CIRCLE option (Carl Zeiss Meditec AG, Jena, Germany), which converts the SMILE cap into a femtosecond LASIK flap for secondary excimer laser application. Of 2,065 SMILE procedures, 22 eyes (1.1%) re-treated with CIRCLE with a follow-up of 3 months were included in the analysis. SMILE was performed in the usual manner. For re-treatment, the CIRCLE procedure was performed with pattern D flap creation on the VisuMax system and subsequent excimer laser ablation with a Zeiss MEL 90 laser (Carl Zeiss Meditec) with plano target in all cases. Spherical equivalent was -5.56 ± 2.22 diopters (D) before SMILE and -0.51 ± 1.08 D before CIRCLE. CIRCLE enhancement was performed after a mean of 10.0 ± 7.9 months, allowed for safe flap lifting in all eyes, and resulted in a final manifest refraction spherical equivalent of 0.18 ± 0.31 D at 3 months (P line of UDVA. Corrected distance visual acuity (CDVA) remained unchanged at all time points (before vs after CIRCLE, P = .40). Two eyes (9.1 %) lost one line of CDVA; no eye lost two or more lines. The safety and efficacy indices were 1.03 and 0.97 at 3 months. The CIRCLE procedure represents an effective re-treatment option after SMILE. Compared to surface ablation re-treatment after SMILE, CIRCLE seems to offer advantages in respect to speed of visual recovery, safety, and predictability, but at the price of flap creation. [J Refract Surg. 2018;34(5):304-309.]. Copyright 2018, SLACK Incorporated.

  6. Logic operations and data storage using vortex magnetization states in mesoscopic permalloy rings, and optical readout

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, S R; Gibson, U J, E-mail: u.gibson@dartmouth.ed [Thayer School of Engineering, Dartmouth College, Hanover, NH 03755-8000 (United States)

    2010-01-01

    Optical coatings applied to one-half of thin film magnetic rings allow real-time readout of the chirality of the vortex state of micro- and nanomagnetic structures by breaking the symmetry of the optical signal. We use this technique to demonstrate data storage, operation of a NOT gate that uses exchange interactions between slightly overlapping rings, and to investigate the use of chains of rings as connecting wires for linking gates.

  7. Neutron scattering. Lectures

    Energy Technology Data Exchange (ETDEWEB)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner (eds.)

    2010-07-01

    The following topics are dealt with: Neutron sources, neutron properties and elastic scattering, correlation functions measured by scattering experiments, symmetry of crystals, applications of neutron scattering, polarized-neutron scattering and polarization analysis, structural analysis, magnetic and lattice excitation studied by inelastic neutron scattering, macromolecules and self-assembly, dynamics of macromolecules, correlated electrons in complex transition-metal oxides, surfaces, interfaces, and thin films investigated by neutron reflectometry, nanomagnetism. (HSI)

  8. Neutron scattering. Lectures

    International Nuclear Information System (INIS)

    Brueckel, Thomas; Heger, Gernot; Richter, Dieter; Roth, Georg; Zorn, Reiner

    2010-01-01

    The following topics are dealt with: Neutron sources, neutron properties and elastic scattering, correlation functions measured by scattering experiments, symmetry of crystals, applications of neutron scattering, polarized-neutron scattering and polarization analysis, structural analysis, magnetic and lattice excitation studied by inelastic neutron scattering, macromolecules and self-assembly, dynamics of macromolecules, correlated electrons in complex transition-metal oxides, surfaces, interfaces, and thin films investigated by neutron reflectometry, nanomagnetism. (HSI)

  9. Linear reciprocating wear behaviour of plasma-sprayed Al2O3 ...

    Indian Academy of Sciences (India)

    Balmukund Dhakar

    2017-08-31

    Aug 31, 2017 ... However, few reports are available on the compound effects of the variations in ... polished samples is studied by using field emission scan- ning electron microscope (FESEM, Zeiss Supra-55). The phases present in the ... calculated by measured track depth and width by Altisurf. 500 optical profiler (figure ...

  10. Porcine circovirus type 2 ORF4 protein binds heavy chain ferritin

    Indian Academy of Sciences (India)

    2015-08-13

    Aug 13, 2015 ... protein is a newly identified viral protein of PCV2 and is involved in ... The porcine alveolar macrophages (PAMs) of a healthy, 2- .... firmation by restriction analysis and DNA sequencing, the ... croscope (Model LSM510 META, Zeiss). ..... circovirus-like viruses from pigs with a wasting disease in the.

  11. Moving vortex matter with coexisting vortices and anti-vortices

    International Nuclear Information System (INIS)

    Carneiro, Gilson

    2009-01-01

    Moving vortex matter, driven by transport currents independent of time, in which vortices and anti-vortices coexist is investigated theoretically in thin superconducting films with nanostructured defects. A simple London model is proposed for the vortex dynamics in films with periodic arrays of nanomagnets or cylindrical holes (antidots). Common to these films is that vortex anti-vortex pairs may be created in the vicinity of the defects by relatively small transport currents, because it adds to the current generated by the defects - the nanomagnets screening current, or the antidots backflow current - and may exceed locally the critical value for vortex anti-vortex pair creation. The model assumes that vortex matter dynamics is governed by Langevin equations, modified to account for creation and annihilation of vortex anti-vortex pairs. For pair creation, it is assumed that whenever the total current at some location exceeds a critical value, equal to that needed to separate a vortex from an anti-vortex by a vortex core diameter, a pair is created instantaneously around this location. Pair annihilation occurs by vortex anti-vortex collisions. The model is applied to films at zero external magnetic field and low temperatures. It is found that several moving vortex matter steady-states with equal numbers of vortices and anti-vortices are possible.

  12. AC susceptometry on the single-molecule magnet Ni{sub 2}Dy

    Energy Technology Data Exchange (ETDEWEB)

    Wendler, Pascal; Sundt, Alexander; Waldmann, Oliver [Physikalisches Institut, Universitaet Freiburg (Germany); Khan, Amin; Lan, Yanhua; Powell, Annie K. [Institute of Inorganic Chemistry, Karlsruhe Institute of Technology (Germany)

    2013-07-01

    Molecular nanomagnets are molecules which show novel and fascinating magnetic properties. The best known phenomenon is the observation of magnetic hysteresis on the molecular scale in the single-molecule magnets (SMMs), such as Mn{sub 12}ac. In addition, quantum mechanical effects, such as the tunneling of the magnetization, can be observed in bulk samples of SMMs. A key goal for understanding the underlying physics is the measurement of the magnetization dynamics, which can be accomplished using ac susceptometry. However, the magnetic moments of samples of SMMs are weak since the volume density of the magnetic ions is very small as compared to e.g. inorganic compounds. In this talk we will describe the construction of an ac susceptometer suitable for investigating molecular nanomagnets. A particular goal was to reach frequencies of the ac field of 100 kHz, extending the frequency range of commercial devices typically used in this research area by two decades. The device can be operated in the temperature range of 1.5 to 300 K and was characterized by comparing data recorded on Mn{sub 19} with available literature results. Lastly, we will present our experimental results on the novel SMM Ni{sub 2}Dy and discuss the different magnetic relaxation regimes observed in it.

  13. Synthesis and optimization of chitosan nanoparticles: Potential applications in nanomedicine and biomedical engineering.

    Science.gov (United States)

    Ghadi, Arezou; Mahjoub, Soleiman; Tabandeh, Fatemeh; Talebnia, Farid

    2014-01-01

    Chitosan nanoparticles have become of great interest for nanomedicine, biomedical engineering and development of new therapeutic drug release systems with improved bioavailability, increased specificity and sensitivity, and reduced pharmacological toxicity. The aim of the present study was to synthesis and optimize of the chitosan nanoparticles for industrial and biomedical applications. Fe3O4 was synthesized and optimized as magnetic core nanoparticles and then chitosan covered this magnetic core. The size and morphology of the nano-magnetic chitosan was analyzed by scanning electron microscope (SEM). Topography and size distribution of the nanoparticles were shown with two-dimensional and three-dimensional images of atomic force microscopy (AFM). The nanoparticles were analyzed using transmission electron microscopy (TEM). The chitosan nanoparticles prepared in the experiment exhibited white powder shape. The SEM micrographs of the nano-magnetic chitosan showed that they were approximately uniform spheres. The unmodified chitosan nanoparticles composed of clusters of nanoparticles with sizes ranging from 10 nm to 80 nm. AFM provides a three-dimensional surface profile. The TEM image showed physical aggregation of the chitosan nanoparticles. The results show that a novel chitosan nanoparticle was successfully synthesized and characterized. It seems that this nanoparticle like the other chitosan nano particles has potential applications for nanomedicine, biomedical engineering, industrial and pharmaceutical fields.

  14. Simulation and design method in advanced nanomaterials fine-tuning for some perovskites type AHE study

    International Nuclear Information System (INIS)

    Mohorianu, S.; Lozovan, M.; Rusu, F.-V.

    2009-01-01

    Nanostructured materials with tailored properties are now essential for future applications in the current industrial manufacturing. Extracting valuable information from data by using the distributed computer processing and storage technologies, as well the Artificial Neural Network (ANN) and the development of advanced algorithms for knowledge discovery are the purpose of our work. We describe how a Simulation and Design Method (SDM) attempt, based on our last results, is applied on two perovskites type materials, La 0.7 Ca 0.3 MnO 3 and La 0.7 Sr 0.3 MnO 3 in order to study the Anomalous Hall Effect (AHE). Our new ANN model, is intended to contribute to the effort to improve some properties of new materials. It implements and uses the basic building blocks of neural computation, such as multi-layer perceptrons. ANN can learn associative patterns and approximate the functional relationship between a set of input and output. Modeling and simulation techniques affect all stages in the development and improvement of new materials, from the initial formation of concepts to synthesis and characterization of properties. A new SDM with ANN for some nanomagnetic materials was given. Neural networks have been applied successfully in the identification and classification of some nanomagnetic characteristics from a large amount of data. (authors)

  15. Compilation of 1993 Annual Reports of the Navy ELF Communications System Ecological Monitoring Program. Volume 3. Tabs G-I

    Science.gov (United States)

    1994-04-01

    10 2 2 Regulus satrapa Ruby-crowned Kinglet 2 10 2 2 Regulus calendula Blue-gray Gnatcatcher 3 10 1 3 Polioptila caerulea Eastern Bluebird 4 12 5 2...on a Zeiss microscope equipped with phase contrast illumination and an oil immersion 10OX Neofluar phase objective with numerical aperture of 1.30

  16. Ants Colony Optimisation of a Measuring Path of Prismatic Parts on a CMM

    Directory of Open Access Journals (Sweden)

    Stojadinovic Slavenko M.

    2016-03-01

    Full Text Available This paper presents optimisation of a measuring probe path in inspecting the prismatic parts on a CMM. The optimisation model is based on: (i the mathematical model that establishes an initial collision-free path presented by a set of points, and (ii the solution of Travelling Salesman Problem (TSP obtained with Ant Colony Optimisation (ACO. In order to solve TSP, an ACO algorithm that aims to find the shortest path of ant colony movement (i.e. the optimised path is applied. Then, the optimised path is compared with the measuring path obtained with online programming on CMM ZEISS UMM500 and with the measuring path obtained in the CMM inspection module of Pro/ENGINEER® software. The results of comparing the optimised path with the other two generated paths show that the optimised path is at least 20% shorter than the path obtained by on-line programming on CMM ZEISS UMM500, and at least 10% shorter than the path obtained by using the CMM module in Pro/ENGINEER®.

  17. Thermal behaviour of strontium tartrate single crystals grown in gel

    Indian Academy of Sciences (India)

    Unknown

    Keywords. Strontium tartrate; dopant; effect of magnetic field; thermal behaviour. 1. Introduction ... tals of such type of compounds cannot be grown by either slow evaporation or ... is observed under a stereo binocular microscope (Carl. Zeiss) and ... a depth of 1⋅8 cm due to the diffusion of the top solution. After about a week ...

  18. Determination of Serum Lithium by Flame Emission Spectroscopy

    Directory of Open Access Journals (Sweden)

    R. Nafissy

    1976-07-01

    Full Text Available Lithum can be de termined both by atomic absorption spectroscopy andflame emission spectroscopy. We have used the later method with a Zeiss Model pMQlI spectro photometer fitt ed with ante-chamber atomizer and a potensiome rric line recorder. Accurate ana lysis for the clement was acco mplished due to a sophisracared measuring instrument.

  19. Artificial ferroic systems: novel functionality from structure, interactions and dynamics

    International Nuclear Information System (INIS)

    Heyderman, L J; Stamps, R L

    2013-01-01

    Lithographic processing and film growth technologies are continuing to advance, so that it is now possible to create patterned ferroic materials consisting of arrays of sub-1 μm elements with high definition. Some of the most fascinating behaviour of these arrays can be realised by exploiting interactions between the individual elements to create new functionality. The properties of these artificial ferroic systems differ strikingly from those of their constituent components, with novel emergent behaviour arising from the collective dynamics of the interacting elements, which are arranged in specific designs and can be activated by applying magnetic or electric fields. We first focus on artificial spin systems consisting of arrays of dipolar-coupled nanomagnets and, in particular, review the field of artificial spin ice, which demonstrates a wide range of fascinating phenomena arising from the frustration inherent in particular arrangements of nanomagnets, including emergent magnetic monopoles, domains of ordered macrospins, and novel avalanche behaviour. We outline how demagnetisation protocols have been employed as an effective thermal anneal in an attempt to reach the ground state, comment on phenomena that arise in thermally activated systems and discuss strategies for selectively generating specific configurations using applied magnetic fields. We then move on from slow field and temperature driven dynamics to high frequency phenomena, discussing spinwave excitations in the context of magnonic crystals constructed from arrays of patterned magnetic elements. At high frequencies, these arrays are studied in terms of potential applications including magnetic logic, linear and non-linear microwave optics, and fast, efficient switching, and we consider the possibility to create tunable magnonic crystals with artificial spin ice. Finally, we discuss how functional ferroic composites can be incorporated to realise magnetoelectric effects. Specifically, we discuss

  20. Artificial ferroic systems: novel functionality from structure, interactions and dynamics.

    Science.gov (United States)

    Heyderman, L J; Stamps, R L

    2013-09-11

    Lithographic processing and film growth technologies are continuing to advance, so that it is now possible to create patterned ferroic materials consisting of arrays of sub-1 μm elements with high definition. Some of the most fascinating behaviour of these arrays can be realised by exploiting interactions between the individual elements to create new functionality. The properties of these artificial ferroic systems differ strikingly from those of their constituent components, with novel emergent behaviour arising from the collective dynamics of the interacting elements, which are arranged in specific designs and can be activated by applying magnetic or electric fields. We first focus on artificial spin systems consisting of arrays of dipolar-coupled nanomagnets and, in particular, review the field of artificial spin ice, which demonstrates a wide range of fascinating phenomena arising from the frustration inherent in particular arrangements of nanomagnets, including emergent magnetic monopoles, domains of ordered macrospins, and novel avalanche behaviour. We outline how demagnetisation protocols have been employed as an effective thermal anneal in an attempt to reach the ground state, comment on phenomena that arise in thermally activated systems and discuss strategies for selectively generating specific configurations using applied magnetic fields. We then move on from slow field and temperature driven dynamics to high frequency phenomena, discussing spinwave excitations in the context of magnonic crystals constructed from arrays of patterned magnetic elements. At high frequencies, these arrays are studied in terms of potential applications including magnetic logic, linear and non-linear microwave optics, and fast, efficient switching, and we consider the possibility to create tunable magnonic crystals with artificial spin ice. Finally, we discuss how functional ferroic composites can be incorporated to realise magnetoelectric effects. Specifically, we discuss

  1. Electron holography for the study of nanomagnetic materials

    DEFF Research Database (Denmark)

    Thomas, John Meurig; Simpson, Edward T.; Kasama, Takeshi

    2008-01-01

    provide important quantitative information, with nanometer-scale spatial resolution, pertaining to such materials’ magnetic properties. In this Account, with the aid of representative examples embracing solid-state chemistry, geochemistry, and bio-inorganic phenomena, we illustrate how off-axis electron...

  2. Nano-Magnets and Additive Manufacturing for Electric Motors

    Science.gov (United States)

    Misra, Ajay K.

    2014-01-01

    High power density is required for application of electric motors in hybrid electric propulsion. Potential path to achieve high power density in electric motors include advanced materials, lightweight thermal management, lightweight structural concepts, high power density power electronics, and advanced manufacturing. This presentation will focus on two key technologies for achieving high power density, advanced magnets and additive manufacturing. The maximum energy product in current magnets is reaching their theoretical limits as a result of material and process improvements. Future improvements in the maximum energy product for magnets can be achieved through development of nanocomposite magnets combining the hard magnetic phase and soft magnetic phase at the nanoscale level. The presentation will provide an overview of the current state of development for nanocomposite magnets and the future path for doubling the maximum energy product. The other part of the presentation will focus on the role of additive manufacturing in fabrication of high power density electric motors. The presentation will highlight the potential opportunities for applying additive manufacturing to fabricate electric motors.

  3. Magnetization behavior of nanomagnets for patterned media application

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, S.; Kikuchi, N.; Kato, T.; Kitakami, O. [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai 980-8577 (Japan); Mitsuzuka, K.; Shimatsu, T.; Muraoka, H.; Aoi, H. [Research Institute of Electrical Communication, Tohoku University, Sendai 980-8577 (Japan); Lodder, J.C. [Information Storage Group, MESA, University of Twente, Enschede 7500 AE (Netherlands)], E-mail: j.c.lodder@el.utwente.nl

    2008-11-15

    Bit patterned media (BPM) which utilize each magnetic nanostructured dot as one recorded bit has attracted much interest as a promising candidate for future high-density magnetic recording. In this study, the magnetization reversal behaviors of nanostructured L1{sub 0}-FePt, Co/Pt multilayer (ML), and CoPt/Ru dots are investigated. For Co/Pt and CoPt/Ru nanodots, the bi-stable state is maintained in a very wide size range up to several hundred nm, and the magnetization reversal is dominated by the nucleation of a small reversed nucleus with the dimension of domain wall width. On the other hand, the critical size for the bi-stability of L1{sub 0}-FePt is about 60 nm, and its magnetization reversal proceeds via domain wall displacement even for such a small dot size. These reversal behaviors, depending on the magnetic materials, might be attributed to the difference in structural inhomogeneity, such as defects. In addition to the magnetic properties, the structural uniformity of the material could be crucial for the BPM application.

  4. Magnetic resonance imaging by using nano-magnetic particles

    Energy Technology Data Exchange (ETDEWEB)

    Shokrollahi, H., E-mail: Shokrollahi@sutech.ac.ir [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Khorramdin, A. [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Isapour, Gh. [Department of Materials and Engineering, Hakim Sabzevari University (Iran, Islamic Republic of)

    2014-11-15

    Magnetism and magnetic materials play a major role in various biological applications, such as magnetic bioseparation, magnetic resonance imaging (MRI), hyperthermia treatment of cancer and drug delivery. Among these techniques, MRI is a powerful method not only for diagnostic radiology but also for therapeutic medicine that utilizes a magnetic field and radio waves. Recently, this technique has contributed greatly to the promotion of the human quality life. Thus, this paper presents a short review of the physical principles and recent advances of MRI, as well as providing a summary of the synthesis methods and properties of contrast agents, like different core materials and surfactants. - Highlights: • This paper studies the physics of MRI as a powerful diagnostic technique. • MRI uses the differentiation between healthy and pathological tissues. • The relaxation times can be shortened by the use of a magnetic contrast agent. • The magnetic nanoparticles act as contrast agents, helping to increase the resolution. • Different synthesis methods can influence the magnetic resonance behavior.

  5. Control of entanglement transitions in quantum spin clusters

    Science.gov (United States)

    Irons, Hannah R.; Quintanilla, Jorge; Perring, Toby G.; Amico, Luigi; Aeppli, Gabriel

    2017-12-01

    Quantum spin clusters provide a platform for the experimental study of many-body entanglement. Here we address a simple model of a single-molecule nanomagnet featuring N interacting spins in a transverse field. The field can control an entanglement transition (ET). We calculate the magnetization, low-energy gap, and neutron-scattering cross section and find that the ET has distinct signatures, detectable at temperatures as high as 5% of the interaction strength. The signatures are stronger for smaller clusters.

  6. Low-power non-volatile spintronic memory: STT-RAM and beyond

    International Nuclear Information System (INIS)

    Wang, K L; Alzate, J G; Khalili Amiri, P

    2013-01-01

    The quest for novel low-dissipation devices is one of the most critical for the future of semiconductor technology and nano-systems. The development of a low-power, universal memory will enable a new paradigm of non-volatile computation. Here we consider STT-RAM as one of the emerging candidates for low-power non-volatile memory. We show different configurations for STT memory and demonstrate strategies to optimize key performance parameters such as switching current and energy. The energy and scaling limits of STT-RAM are discussed, leading us to argue that alternative writing mechanisms may be required to achieve ultralow power dissipation, a necessary condition for direct integration with CMOS at the gate level for non-volatile logic purposes. As an example, we discuss the use of the giant spin Hall effect as a possible alternative to induce magnetization reversal in magnetic tunnel junctions using pure spin currents. Further, we concentrate on magnetoelectric effects, where electric fields are used instead of spin-polarized currents to manipulate the nanomagnets, as another candidate solution to address the challenges of energy efficiency and density. The possibility of an electric-field-controlled magnetoelectric RAM as a promising candidate for ultralow-power non-volatile memory is discussed in the light of experimental data demonstrating voltage-induced switching of the magnetization and reorientation of the magnetic easy axis by electric fields in nanomagnets. (paper)

  7. Macroscopic and microscopic structural integrity in magnetic colloids-cationic micellar solution: Rheology, SANS and magneto-optical study

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rajesh, E-mail: rjp@bhavuni.ed [Department of Physics, Bhavnagar University, Bhavnagar 364 022 (India); Upadhyay, R.V., E-mail: rvu.as@ecchanga.ac.i [Charotar Institute of Applied Sciences, Education Campus, Changa 388421, Anand, Gujarat (India); Aswal, V.K. [Solid State Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Joshi, J.V.; Goyal, P.S. [UGC- DAE Consortium for Scientific Research, Mumbai Centre, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India)

    2011-03-15

    A stable mixture of two colloid system composed of double surfactant coated aqueous nanomagnetic fluid and aqueous micellar solution of cationic micelles of cetyletrymethyl ammonium bromide (CTABr) is prepared as a function of nanomagnetic fluid concentration. This mixed system is analyzed using three techniques such as zero field and field induced viscosity measurements, Small Angle Neutron Scattering technique and magneto-optical birefringence measurements. In field induced viscosity measurement it is observed that even 20% magnetic fluid concentration in CTABr aqueous solution shows 75% increase in viscosity compared to pure magnetic fluid. This suggests that in presence of CTABr micelles, a novel magneto rheological effect for low concentration of magnetic fluid is observed. From SANS measurements it is observed that aggregation number and a/b ratio increases with magnetic fluid concentration and magnetic birefringence reveals non-superimpose behavior of normalized field induced retardation. Results of these experiments are compared and indicate zero fields and field induced structural integrity between magnetic particles and soft micelles. - Research Highlights: {yields} This study exhibits zero field and field induced structural integrity between soft micelles and magnetic nanoparticles. {yields} The techniques used are viscosity measurements, Small Angle Neutron Scattering technique and magneto-optical birefringence. {yields} Study is useful for magnetic hyperthermia via micelles, as soft actuators, as an artificial micro-muscles, micro-manipulators, etc.

  8. Effet de l'amendement au carbonate de calcium (mikhart) de ...

    African Journals Online (AJOL)

    SARAH

    31 janv. 2017 ... control substratum, SCa10 (S0 + 10 % powder of calcium carbonate), SCa20 (S0 + 20 % powder of calcium carbonate), SCa30 (S0 ..... puis montés sur un microscope électronique FEG Supra. 40 VP Zeiss à balayage et pression variable. Dès lors, ..... substrats amendés d'un apport en quantité et en qualité.

  9. Compilation of 1991 Annual Reports of the Navy ELF Communications Systems Ecological Monitoring Program

    Science.gov (United States)

    1992-08-01

    crowned Kinglet 46 36 48 31 49 40 7 12 15 11 Reaulus satraoaa I Ruby-crowned Kinglet 19 9 4 2 1 0 0 0 1 0 Regulus calendula I Eastern Bluebird 0 0 3 2 0 0...determinations was done at 1250X magnification on a Zeiss microscope equipped with phase contrast illumination and an oil immersion 10OX Neofluar phase

  10. Effect of thermal fluctuations in spin-torque driven magnetization dynamics

    International Nuclear Information System (INIS)

    Bonin, R.; Bertotti, G.; Serpico, C.; Mayergoyz, I.D.; D'Aquino, M.

    2007-01-01

    Nanomagnets with uniaxial symmetry driven by an external field and spin-polarized currents are considered. Anisotropy, applied field, and spin polarization are all aligned along the symmetry axis. Thermal fluctuations are described by adding a Gaussian white noise stochastic term to the Landau-Lifshitz-Gilbert equation for the deterministic dynamics. The corresponding Fokker-Planck equation is derived. It is shown that deterministic dynamics, thermal relaxation, and transition rate between stable states are governed by an effective potential including the effect of current injection

  11. Effect of thermal fluctuations in spin-torque driven magnetization dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Bonin, R. [INRiM, I-10135 Turin (Italy)]. E-mail: bonin@inrim.it; Bertotti, G. [INRiM, I-10135 Turin (Italy); Serpico, C. [Dipartimento di Ingegneria Elettrica, Universita di Napoli ' Federico II' I-80125 Naples (Italy); Mayergoyz, I.D. [Department of Electrical and Computer Engineering, University of Maryland, College Park, MD 20742 (United States); D' Aquino, M. [Dipartimento per le Tecnologie, Universita di Napoli ' Parthenope' , I-80133 Naples (Italy)

    2007-09-15

    Nanomagnets with uniaxial symmetry driven by an external field and spin-polarized currents are considered. Anisotropy, applied field, and spin polarization are all aligned along the symmetry axis. Thermal fluctuations are described by adding a Gaussian white noise stochastic term to the Landau-Lifshitz-Gilbert equation for the deterministic dynamics. The corresponding Fokker-Planck equation is derived. It is shown that deterministic dynamics, thermal relaxation, and transition rate between stable states are governed by an effective potential including the effect of current injection.

  12. Analytical study of synchronization in spin-transfer-driven magnetization dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Bonin, Roberto [Politecnico di Torino - sede di Verres, via Luigi Barone 8, I-11029 Verres (Italy); Bertotti, Giorgio; Bortolotti, Paolo [Istituto Nazionale di Ricerca Metrologica, Strada delle Cacce 91, I-10135 Torino (Italy); Serpico, Claudio [Dipartimento di Ingegneria Elettrica, Universita di Napoli ' Federico II' , via Claudio 21, I-80125 Napoli (Italy); D' Aquino, Massimiliano [Dipartimento per le Tecnologie, Universita di Napoli ' Parthenope' , via Medina 40, I-80133 Napoli (Italy); Mayergoyz, Isaak D, E-mail: p.bortolotti@inrim.i [Electrical and Computer Engineering Department and UMIACS, University of Maryland, College Park MD 20742 (United States)

    2010-01-01

    An analytical study of the synchronization effects in spin-transfer-driven nanomagnets subjected to either microwave magnetic fields or microwave electrical currents is discussed. Appropriate stability diagrams are constructed and the conditions under which the current-induced magnetization precession is synchronized by the microwave external excitation are derived and discussed. Analytical predictions are given for the existence of phase-locking effects in current-induced magnetization precessions and for the occurrence of hysteresis in phase-locking as a function of the spin-polarized current.

  13. Development of Novel Magnetic Metal Oxide Thin Films and Carbon Nanotube Materials for Potential Device Applications

    Science.gov (United States)

    2016-05-09

    9 3 Fe/MWCNTs/ SiO2 and Nano...magnetization measurements -1.5 0.0 1.5 To rq ue (a .u .) IP H = 1.9 T CoFe2 on glass in-Field -1.5 0.0 1.5 To rq ue (a . u .) 360300240180120600 Field Angle...deg.) IP H = 1.9 T CoFe2 on glass no-Field a b Fig. 2.3: Torque magnetometry for CoFe2 layer deposited (a) in-field and (b) deposited with no

  14. Efeitos da hiperprolactinemia sobre o útero de camundongos no proestro Hyperprolactinemia effects on the female mice uterus during proestrous

    Directory of Open Access Journals (Sweden)

    Regina Célia Teixeira Gomes

    2009-08-01

    Full Text Available OBJETIVO: avaliar o efeito da hiperprolactinemia induzida pela metoclopramida sobre o endométrio e miométrio de camundongos fêmeas na fase de proestro. MÉTODOS: 24 camundongos fêmeas foram divididas aleatoriamente em dois grupos: GCtr/controle e GExp/tratadas com metoclopramida (6,7 µg/g por dia. Após 50 dias, os animais foram sacrificados na fase de proestro, e o sangue foi coletado para determinação dos níveis de estradiol, progesterona e prolactina. Os cornos uterinos foram removidos e fixados em formol a 10%; foram, então, processados para inclusão em parafina. Cortes de 4 µm foram corados pela hematoxilina-eosina (H/E. Na análise morfológica, foi utilizado microscópio de luz, da marca Carl Zeiss, com objetivas variando de 4 a 400 X, para caracterização de cada corte histológico. Na análise morfométrica, foi avaliada a espessura do epitélio superficial, da lâmina própria e do miométrio, com auxílio de um analisador de imagem (AxionVision, Carl Zeiss acoplado ao microscópio de luz (Carl Zeiss. A análise estatística foi realizada pela ANOVA seguida pelo teste Wilcoxon. O valor de p foi considerado significante quando PURPOSE: to evaluate the effect of hyperprolactinemia induced by metoclopramide on the endometrium and myometrium of female mice in the proestrus phase. METHODS: 24 female mice were randomly divided in two groups: CtrG/control and ExpG/treated with metoclopramide (6.7 mg/g daily. After 50 days, the animals were sacrificed in the proestrus phase, and the blood was collected to determine the levels of estradiol, progesterone and prolactin. The uterine horns were removed, fixed in 10% formaldehyde and processed before being included in paraffin. Slices of 4 µm were stained by hematoxylin and eosin (H/E. In the morphological analysis, a Carl Zeiss light microscope, with objectives varying from 4 to 400 X was used for each histological slice characterization. In the morphometrical analysis, the superficial

  15. INTRASURGICAL MICROSCOPE-INTEGRATED SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY-ASSISTED MEMBRANE PEELING.

    Science.gov (United States)

    Falkner-Radler, Christiane I; Glittenberg, Carl; Gabriel, Max; Binder, Susanne

    2015-10-01

    To evaluate microscope-integrated intrasurgical spectral domain optical coherence tomography during macular surgery in a prospective monocenter study. Before pars plana vitrectomy and before, during, and after membrane peeling, 512 × 128 macular cube scans were performed using a Carl Zeiss Meditec Cirrus high-definition OCT system adapted to the optical pathway of a Zeiss OPMI VISU 200 surgical microscope and compared with retinal staining. The study included 51 patients with epiretinal membranes, with 8 of those having additional lamellar macular holes, 11 patients with vitreomacular traction, and 8 patients with full-thickness macular holes. Intraoperative spectral domain optical coherence tomography allowed performing membrane peeling without using retinal dyes in 40% of cases (28 of 70 patients). No residual membranes were found in 94.3% of patients (66 of 70 patients) in intrasurgical spectral domain optical coherence tomography and subsequent (re)staining. In patients with vitreomacular traction, intrasurgical spectral domain optical coherence tomography scans facilitated decisions on the need for an intraocular tamponade after membrane peeling. Intraoperative spectral domain optical coherence tomography was comparable with retinal dyes in confirming success after membrane peeling. However, the visualization of flat membranes was better after staining.

  16. Pseudo-gonio synechia: an artifact on two-mirror gonioscopy.

    Science.gov (United States)

    Garudadri, Chandra Sekhar

    2010-01-01

    Gonioscopy is an important component of evaluation of any glaucoma patient. Goldmann two-mirror and Sussman or Zeiss four-mirror are the commonly used gonioscopes. Presence of synechia in the angle is diagnostic of angle closure disease in an occludable angle. A patient with pseudo-gonio synechia that disappeared on indentation gonioscopy with Sussman lens but persisted with manipulation gonioscopy with a Goldmann lens is reported.

  17. Pseudo-gonio synechia: An artifact on two-mirror gonioscopy

    OpenAIRE

    Garudadri, Chandra Sekhar

    2010-01-01

    Gonioscopy is an important component of evaluation of any glaucoma patient. Goldmann two-mirror and Sussman or Zeiss four-mirror are the commonly used gonioscopes. Presence of synechia in the angle is diagnostic of angle closure disease in an occludable angle. A patient with pseudo-goniosynechia that disappeared on indentation gonioscopy with Sussman lens but persisted with manipulation gonioscopy with a Goldmann lens is reported.

  18. Superconductivity and magnetism: Materials properties and developments

    International Nuclear Information System (INIS)

    Andersen, N.H.; Bay, N.; Grivel, J.C.

    2003-01-01

    The 24th Risoe International Symposium on Materials Science focuses on development of new materials, devices and applications, as well as experimental and theoretical studies of novel and unexplained phenomena in superconductivity and magnetism, e.g. within high.T c superconductivity, magnetic superconductors, MgB 2 , CMR materials, nanomagnetism and spin-tronics. The aim is to stimulate exchange of ideas and establish new collaborations between leading Danish and international scientists. The topics are addressed by presentations from 24 invited speakers and by 41 contributed papers. (ln)

  19. Nonadiabatic Berry phase in nanocrystalline magnets

    Directory of Open Access Journals (Sweden)

    R. Skomski

    2017-05-01

    Full Text Available It is investigated how a Berry phase is created in polycrystalline nanomagnets and how the phase translates into an emergent magnetic field and into a topological Hall-effect contribution. The analysis starts directly from the spin of the conduction electrons and does not involve any adiabatic Hamiltonian. Completely random spin alignment in the nanocrystallites does not lead to a nonzero emergent field, but a modulation of the local magnetization does. As an explicit example, we consider a wire with a modulated cone angle.

  20. Comparison of the biometric measurements calculated with Zeiss IOL-Master and WaveLight OB-820

    Directory of Open Access Journals (Sweden)

    Labiris G

    2017-04-01

    Full Text Available Georgios Labiris,1,2 Panagiota Ntonti,2 Konstantinos Ntitsos,2 Andreas Katsanos,2 Haris Sideroudi,2 Vasilios Kozobolis1,2 1Department of Ophthalmology, University Hospital of Alexandroupolis, 2Eye Institute of Thrace, Alexandroupolis, Greece Background: The primary objective of this study was to investigate the level of agreement between IOL-Master and OB-820 ocular biometers.Materials and methods: In this prospective randomized case series, we measured the anterior chamber depth (ACD, the axial length (AL, the corneal radii (R1, R2, the ratio of mean corneal radius and spherical equivalent and the corneal astigmatism (cylinder [Cyl] before and after cataract extraction surgery.Results: Significant differences between pre- and postoperative data were observed for ACD for both biometric devices (P<0.01 and Cyl parameter in IOL-Master. Range and 95% limits of agreement (LoA were clinically significantly different for AL parameter pre- and postoperatively and for R2 and radius and spherical equivalent postoperatively (P<0.001. The rest of the parameters presented sufficient 95% LoA, which imply good agreement.Conclusion: In clinical practice, the IOL-master and OB-820 should not be used interchangeably due to discrepancy in the important AL parameter. Both biometers may provide consistent results regarding Cyl, ACD and R1. Keywords: cataract, IOL-Master, OB-820, biometry, level of agreement

  1. Stochastic p -Bits for Invertible Logic

    Science.gov (United States)

    Camsari, Kerem Yunus; Faria, Rafatul; Sutton, Brian M.; Datta, Supriyo

    2017-07-01

    Conventional semiconductor-based logic and nanomagnet-based memory devices are built out of stable, deterministic units such as standard metal-oxide semiconductor transistors, or nanomagnets with energy barriers in excess of ≈40 - 60 kT . In this paper, we show that unstable, stochastic units, which we call "p -bits," can be interconnected to create robust correlations that implement precise Boolean functions with impressive accuracy, comparable to standard digital circuits. At the same time, they are invertible, a unique property that is absent in standard digital circuits. When operated in the direct mode, the input is clamped, and the network provides the correct output. In the inverted mode, the output is clamped, and the network fluctuates among all possible inputs that are consistent with that output. First, we present a detailed implementation of an invertible gate to bring out the key role of a single three-terminal transistorlike building block to enable the construction of correlated p -bit networks. The results for this specific, CMOS-assisted nanomagnet-based hardware implementation agree well with those from a universal model for p -bits, showing that p -bits need not be magnet based: any three-terminal tunable random bit generator should be suitable. We present a general algorithm for designing a Boltzmann machine (BM) with a symmetric connection matrix [J ] (Ji j=Jj i) that implements a given truth table with p -bits. The [J ] matrices are relatively sparse with a few unique weights for convenient hardware implementation. We then show how BM full adders can be interconnected in a partially directed manner (Ji j≠Jj i) to implement large logic operations such as 32-bit binary addition. Hundreds of stochastic p -bits get precisely correlated such that the correct answer out of 233 (≈8 ×1 09) possibilities can be extracted by looking at the statistical mode or majority vote of a number of time samples. With perfect directivity (Jj i=0 ) a small

  2. Localized magnetic fields in arbitrary directions using patterned nanomagnets

    DEFF Research Database (Denmark)

    McNeil, Robert P G; Schneble, Jeff; Kataoka, Masaya

    2010-01-01

    Control of the local magnetic fields desirable for spintronics and quantum information technology is not well developed. Existing methods produce either moderately small local fields or one held orientation. We present designs of patterned magnetic elements that produce remanent fields of 50 mT (...

  3. Rational design and modelling of f-block molecular nanomagnets

    OpenAIRE

    Baldoví Jachán, José Jaime

    2016-01-01

    Los imanes monomoleculares o moléculas imán, por sus siglas en inglés SMMs, han suscitado una gran atención en los últimos años debido a sus extraordinarias propiedades físicas. Los cristales de este tipo de moléculas se caracterizan por presentar relajación lenta de la magnetización a baja temperatura, así como curvas de histeresis magnética. Estas moléculas se encuentran entre las entidades con comportamiento magnético más complejas, mostrando fenómenos cuánticos tales como efecto túnel en ...

  4. Bringing nanomagnetism to the mesoscale with artificial amorphous structures

    Science.gov (United States)

    Muscas, G.; Brucas, R.; Jönsson, P. E.

    2018-05-01

    In the quest for materials with emergent or improved properties, an effective route is to create artificial superstructures. Novel properties emerge from the coupling between the phases, but the strength of this coupling depends on the quality of the interfaces. Atomic control of crystalline interfaces is notoriously complicated and to elude that obstacle, we suggest here an all-amorphous design. Starting from a model amorphous iron alloy, we locally tune the magnetic behavior by creating boron-doped regions by means of ion implantation through a lithographic mask. This process preserves the amorphous environment, creating a non-topographic magnetic superstructure with smooth interfaces and no structural discontinuities. The absence of inhomogeneities acting as pinning centers for the magnetization reversal is demonstrated by the formation of magnetic vortexes for ferromagnetic disks as large as 20 µm in diameter embedded within a paramagnetic matrix. Rigid exchange coupling between two amorphous ferromagnetic phases in a microstructured sample is evidenced by an investigation involving first-order reversal curves. The sample consists of a soft matrix with embedded elements constituting a hard phase where the anisotropy originates from an elongated shape of the elements. We provide an intuitive explanation for the micrometer-range exchange coupling mechanism and discuss how to tailor the properties of all-amorphous superstructures.

  5. Nano-magnetic particles as multifunctional microreactor for deep desulfurization

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Xinai; Yao, Dongdong [Engineering Research Center of Historical and Cultural Heritage Protection, Ministry of Education, School of Materials Science and Engineering, Shaanxi Normal University, Xi' an 710062 (China); Li, Hong [College of Environment and Chemical Engineering, Xi' an Polytechnic University, Xi' an 710048 (China); Yang, Juxiang [Department of Chemistry, Xi' an University of Arts and Science, Xi' an 710065 (China); Hu, Daodao, E-mail: daodaohu@snnu.edu.cn [Engineering Research Center of Historical and Cultural Heritage Protection, Ministry of Education, School of Materials Science and Engineering, Shaanxi Normal University, Xi' an 710062 (China)

    2012-02-29

    Highlights: Black-Right-Pointing-Pointer An easy-separated amphiphilic catalyst with small size was prepared for deep desulfurization. Black-Right-Pointing-Pointer The effects of several factors on desulfurization reactivity were systematically investigated. Black-Right-Pointing-Pointer The catalyst demonstrates high performance in the deep desulfurization. Black-Right-Pointing-Pointer The material could make integration of micro-reactor and micro-extractor into one system. - Abstract: Oxidation of dibenzothiophene with hydrogen peroxide using a recyclable amphiphilic catalyst has been studied. The catalyst was synthesized by surfacely covering magnetic silica nanospheres (MSN) with the complexes between 3-(trimethoxysilyl)-propyldimethyloctadecyl ammonium chloride (AEM) and phosphotungstic acid (PTA). The morphology and components of the composite material were characterized by TEM, EDX, XPS, FT-IR, and VSM, respectively. The effects of several factors on desulfurization reactivity were systematically investigated. The results showed that the composite nanospheres have core/shell structure with the properties of amphiphilicity and superparamagnetism. The composite nanospheres have high catalytic activity in the oxidation of dibenzothiophene to corresponding sulfones by hydrogen peroxide under mild reaction conditions. The sulfur level could be lowered from 487 ppm to less than 0.8 ppm under optimal conditions. Additionally, the amphiphilic catalyst and the oxidized product could be simultaneously separated from medium by external magnetism, and the recovered composite material could be recycled for three times with almost constant activity.

  6. Nano-magnetic particles as multifunctional microreactor for deep desulfurization

    International Nuclear Information System (INIS)

    Cui, Xinai; Yao, Dongdong; Li, Hong; Yang, Juxiang; Hu, Daodao

    2012-01-01

    Highlights: ► An easy-separated amphiphilic catalyst with small size was prepared for deep desulfurization. ► The effects of several factors on desulfurization reactivity were systematically investigated. ► The catalyst demonstrates high performance in the deep desulfurization. ► The material could make integration of micro-reactor and micro-extractor into one system. - Abstract: Oxidation of dibenzothiophene with hydrogen peroxide using a recyclable amphiphilic catalyst has been studied. The catalyst was synthesized by surfacely covering magnetic silica nanospheres (MSN) with the complexes between 3-(trimethoxysilyl)-propyldimethyloctadecyl ammonium chloride (AEM) and phosphotungstic acid (PTA). The morphology and components of the composite material were characterized by TEM, EDX, XPS, FT-IR, and VSM, respectively. The effects of several factors on desulfurization reactivity were systematically investigated. The results showed that the composite nanospheres have core/shell structure with the properties of amphiphilicity and superparamagnetism. The composite nanospheres have high catalytic activity in the oxidation of dibenzothiophene to corresponding sulfones by hydrogen peroxide under mild reaction conditions. The sulfur level could be lowered from 487 ppm to less than 0.8 ppm under optimal conditions. Additionally, the amphiphilic catalyst and the oxidized product could be simultaneously separated from medium by external magnetism, and the recovered composite material could be recycled for three times with almost constant activity.

  7. Ultrastructural features of Mimulus aurantiacus (Scrophulariaceae) pollen tubes in vivo

    OpenAIRE

    Ekici,Nuran; Dane,Feruzan; Olgun,Göksel

    2009-01-01

    The aim of this study is to give information on ultrastructure of in vivo pollen tubes of Mimulus aurantiacus which were collected from the Botanical Garden of the University of California at Berkeley. Materials were prepared according to electron microscopy methods and examined under Zeiss electron microscope. Four zones were examined in the pollen tubes of Mimulus aurantiacus. APICAL ZONE: Mitochondria, smooth endoplasmic reticulum, rough endoplasmic reticulum, dictyosomes and secretory ves...

  8. Direct Functionalization of Kevlar (registered trademark) with Copolymers Containing Sulfonyl Nitrene

    Science.gov (United States)

    2016-01-01

    alumina plug. Methacrylic acid was purified by vacuum distillation. Penta- fluorophenol acrylate was synthesized according to a pre- viously published...megapixel digital camera on a Zeiss AX10 Observer inverted microscope with an X-cite Series 120 fluorescent light source and Chroma Technol- ogy filter...Polypentafluorophenolacrylate-co-styrene sulfonyl azide (pPFPA-co-SSAz) (7) 1.0 g (4.2 mmol) of pentafluorophenol acrylate , 46 mg (0.22 mmol) styrene

  9. Diabetes induces changes in neuroretina before retinal vessels: a spectral-domain optical coherence tomography study

    OpenAIRE

    Rodrigues, Eduardo B?chele; Urias, M?ller Gon?alves; Penha, Fernando Marcondes; Badar?, Emmerson; Novais, Eduardo; Meirelles, Rodrigo; Farah, Michel Eid

    2015-01-01

    Purpose To investigate retinal changes prior to vascular signs in patients with type 2 diabetes without diabetic retinopathy or with mild non proliferative diabetic retinopathy. Methods A cross-sectional study was performed in three groups: patients without diabetes, patients with type 2 diabetes without diabetic retinopathy, and patients with diabetes with mild diabetic retinopathy. Analysis of retinal layers was performed objectively with the Cirrus Review Software 6.0 (Carl Zeiss Meditec, ...

  10. Pseudo-gonio synechia: An artifact on two-mirror gonioscopy

    Directory of Open Access Journals (Sweden)

    Garudadri Chandra

    2010-01-01

    Full Text Available Gonioscopy is an important component of evaluation of any glaucoma patient. Goldmann two-mirror and Sussman or Zeiss four-mirror are the commonly used gonioscopes. Presence of synechia in the angle is diagnostic of angle closure disease in an occludable angle. A patient with pseudo-goniosynechia that disappeared on indentation gonioscopy with Sussman lens but persisted with manipulation gonioscopy with a Goldmann lens is reported.

  11. Superconductivity and magnetism: Materials properties and developments

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, N H; Bay, N; Grivel, J C [and others

    2003-07-01

    The 24th Risoe International Symposium on Materials Science focuses on development of new materials, devices and applications, as well as experimental and theoretical studies of novel and unexplained phenomena in superconductivity and magnetism, e.g. within high.T{sub c} superconductivity, magnetic superconductors, MgB{sub 2}, CMR materials, nanomagnetism and spin-tronics. The aim is to stimulate exchange of ideas and establish new collaborations between leading Danish and international scientists. The topics are addressed by presentations from 24 invited speakers and by 41 contributed papers. (ln)

  12. Inter-cluster coupling effects in high-spin molecular magnets

    International Nuclear Information System (INIS)

    Affronte, M.; Lasjaunias, J.C.; Wernsdorfer, W.; Sessoli, R.; Gatteschi, D.; Heath, S.L.; Fort, A.; Rettori, A.

    2004-01-01

    We report evidences of antiferromagnetic (AF) transition in Fe 19 metheidi, a new molecular nanomagnet with a total spin S=((33)/(2)), among the highest known so far. The temperature (T) dependence of specific heat (C) shows a λ-anomaly at 1.19 K and at the same temperature an anomaly is also observed in the low field (B<0.12 T) magnetization M-vs.-T curves. Since the dipolar interaction between clusters is estimated to be ∼190 mK, the origin of the AF transition is probably due to superexchange

  13. Inter-cluster coupling effects in high-spin molecular magnets

    Energy Technology Data Exchange (ETDEWEB)

    Affronte, M.; Lasjaunias, J.C.; Wernsdorfer, W.; Sessoli, R.; Gatteschi, D.; Heath, S.L.; Fort, A. E-mail: fort@fi.infn.it; Rettori, A

    2004-05-01

    We report evidences of antiferromagnetic (AF) transition in Fe{sub 19}metheidi, a new molecular nanomagnet with a total spin S=((33)/(2)), among the highest known so far. The temperature (T) dependence of specific heat (C) shows a {lambda}-anomaly at 1.19 K and at the same temperature an anomaly is also observed in the low field (B<0.12 T) magnetization M-vs.-T curves. Since the dipolar interaction between clusters is estimated to be {approx}190 mK, the origin of the AF transition is probably due to superexchange.

  14. Challenges and opportunities with spin-based logic

    Science.gov (United States)

    Perricone, Robert; Niemier, Michael; Hu, X. Sharon

    2017-09-01

    In this paper, we provide a short overview of efforts to process information with spin as a state variable. We highlight initial efforts in spintronics where devices concepts such as spinwaves, field coupled nanomagnets, etc. were are considered as vehicles for processing information. We also highlight more recent work where spintronic logic and memory devices are considered in the context of information processing hardware for the internet of things (IoT), and where the ability to constantly "checkpoint" processor state can support computing in environments with unreliable power supplies.

  15. Comparison of LED and Conventional Fluorescence Microscopy for Detection of Acid Fast Bacilli in a Low-Incidence Setting

    Science.gov (United States)

    Minion, Jessica; Pai, Madhukar; Ramsay, Andrew; Menzies, Dick; Greenaway, Christina

    2011-01-01

    Introduction Light emitting diode fluorescence microscopes have many practical advantages over conventional mercury vapour fluorescence microscopes, which would make them the preferred choice for laboratories in both low- and high-resource settings, provided performance is equivalent. Methods In a nested case-control study, we compared diagnostic accuracy and time required to read slides with the Zeiss PrimoStar iLED, LW Scientific Lumin, and a conventional fluorescence microscope (Leica DMLS). Mycobacterial culture was used as the reference standard, and subgroup analysis by specimen source and organism isolated were performed. Results There was no difference in sensitivity or specificity between the three microscopes, and agreement was high for all comparisons and subgroups. The Lumin and the conventional fluorescence microscope were equivalent with respect to time required to read smears, but the Zeiss iLED was significantly time saving compared to both. Conclusions Light emitting diode microscopy should be considered by all tuberculosis diagnostic laboratories, including those in high income countries, as a replacement for conventional fluorescence microscopes. Our findings provide support to the recent World Health Organization policy recommending that conventional fluorescence microscopy be replaced by light emitting diode microscopy using auramine staining in all settings where fluorescence microscopy is currently used. PMID:21811622

  16. Comparison of LED and conventional fluorescence microscopy for detection of acid fast bacilli in a low-incidence setting.

    Directory of Open Access Journals (Sweden)

    Jessica Minion

    Full Text Available INTRODUCTION: Light emitting diode fluorescence microscopes have many practical advantages over conventional mercury vapour fluorescence microscopes, which would make them the preferred choice for laboratories in both low- and high-resource settings, provided performance is equivalent. METHODS: In a nested case-control study, we compared diagnostic accuracy and time required to read slides with the Zeiss PrimoStar iLED, LW Scientific Lumin, and a conventional fluorescence microscope (Leica DMLS. Mycobacterial culture was used as the reference standard, and subgroup analysis by specimen source and organism isolated were performed. RESULTS: There was no difference in sensitivity or specificity between the three microscopes, and agreement was high for all comparisons and subgroups. The Lumin and the conventional fluorescence microscope were equivalent with respect to time required to read smears, but the Zeiss iLED was significantly time saving compared to both. CONCLUSIONS: Light emitting diode microscopy should be considered by all tuberculosis diagnostic laboratories, including those in high income countries, as a replacement for conventional fluorescence microscopes. Our findings provide support to the recent World Health Organization policy recommending that conventional fluorescence microscopy be replaced by light emitting diode microscopy using auramine staining in all settings where fluorescence microscopy is currently used.

  17. The effect of laser unit on photodynamic therapy spot size.

    Science.gov (United States)

    Ansari-Shahrezaei, Siamak; Binder, Susanne; Stur, Michael

    2011-01-01

    To determine the effect of the laser unit on photodynamic therapy (PDT) spot size. A calibrated Gullstrand-type model eye was used for this study. The axial length of the model eye was set to different values ranging from 22.2 to 27.0 mm, and the actual spot size from the laser console was recorded for treating a spot of 4 mm in the center of the artificial fundus using two different laser units (Coherent Opal laser; Coherent Inc, Santa Clara, California, USA and Zeiss Visulas laser; Carl Zeiss Meditec Inc, Dublin, California, USA) and two indirect contact laser lenses (Volk PDT laser lens and Volk Area Centralis lens; Volk Optical Inc, Mentor, Ohio, USA). From myopia to hyperopia, the total deviation from the intended spot size was -22.5% to -7.5% (Opal laser and PDT laser lens), and -17.5% to +2.5% (Visulas laser and PDT laser lens), -12.5% to +7.5% (Opal laser and Area Centralis lens), and -7.5% to +10% (Visulas laser and Area Centralis lens). The used laser unit has a significant effect on PDT spot size in this model. These findings may be important for optimizing PDT of choroidal neovascular lesions.

  18. Topological laser speckle analyzer of differentiation and proliferation activity during morphogenesis in cell cultures

    OpenAIRE

    Notchenko A.V.; Gradov O.V.

    2011-01-01

    An automated system for morpho-topological determination of cell division phases and structur al differentiation of tissues during morphogenesis was implemented on the basis of topological properties of cell cultures, considered within the framework of set and manifold theories. A simple robotic hardware and software system based on Zeiss microscope with a modified stage and a Velleman manipulator KSR-1 allow to control the laser module position, carrying out the angular irradiation of s...

  19. Magnetic properties of a classical XY spin dimer in a “planar” magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Ciftja, Orion, E-mail: ogciftja@pvamu.edu [Department of Physics, Prairie View A& M University, Prairie View, TX 77446 (United States); Prenga, Dode [Department of Physics, Faculty of Natural Sciences, University of Tirana, Bul. Zog I, Tirana (Albania)

    2016-10-15

    Single-molecule magnetism originates from the strong intra-molecular magnetic coupling of a small number of interacting spins. Such spins generally interact very weakly with the neighboring spins in the other molecules of the compound, therefore, inter-molecular spin couplings are negligible. In certain cases the number of magnetically coupled spins is as small as a dimer, a system that can be considered the smallest nanomagnet capable of storing non-trivial magnetic information on the molecular level. Additional interesting patterns arise if the spin motion is confined to a two-dimensional space. In such a scenario, clusters consisting of spins with large-spin values are particularly attractive since their magnetic interactions can be described well in terms of classical Heisenberg XY spins. In this work we calculate exactly the magnetic properties of a nanomagnetic dimer of classical XY spins in a “planar” external magnetic field. The problem is solved by employing a mathematical approach whose idea is the introduction of auxiliary spin variables into the starting expression of the partition function. Results for the total internal energy, total magnetic moment, spin–spin correlation function and zero-field magnetic susceptibility can serve as a basis to understand the magnetic properties of large-spin dimer building blocks. - Highlights: • Exact magnetic properties of a dimer system of classical XY spins in magnetic field. • Partition function in nonzero magnetic field obtained in closed-form. • Novel exact analytic results are important for spin models in a magnetic field. • Result provides benchmarks to gauge the accuracy of computational techniques.

  20. Investment Casting vs Replicast CS Considered in Terms of the Ceramic Mould Making and Dimensional Accuracy of Castings

    Directory of Open Access Journals (Sweden)

    Karwiński A.

    2014-03-01

    Full Text Available The article presents an analysis of the applicability of the Replicast CS process as an alternative to the investment casting process, considered in terms of the dimensional accuracy of castings. Ceramic shell moulds were based on the Ekosil binder and a wide range of ceramic materials, such as crystalline quartz, fused silica, aluminosilicates and zirconium silicate. The linear dimensions were measured with a Zeiss UMC 550 machine that allowed reducing to minimum the measurement uncertainty

  1. Effect of Bleaching on Color Change and Surface Topography of Composite Restorations

    OpenAIRE

    Pruthi, Gunjan; Jain, Veena; Kandpal, H. C.; Mathur, Vijay Prakash; Shah, Naseem

    2010-01-01

    This study was conducted to determine the effect of 15% carbamide peroxide bleaching agent on color change and surface topography of different composite veneering materials (Filtek Z350 (3M ESPE), Esthet X (Dentsply India), and Admira (Voco, Germany). Methods. 30 samples were fabricated for evaluation of color change using CIELAB color system and Gonioreflectometer (GK 311/M, ZEISS). 45 disc-shaped specimens were made for evaluation of surface topography after bleaching (Nupro White Gold; Den...

  2. Fluorimetric routine determination of uranium in urine samples

    International Nuclear Information System (INIS)

    Widua, L.; Schieferdecker, H.; Hezel, U.

    With a modified RA 2 reflectance accessory for the Zeiss PMQII/PMQ3 spectrophotometer, uranium in urine was detected with higher sensitivity. A quick method is now available with a detection limit of <2 μg U/1 urine for the determination of possible uranium incorporations, whose sensitivity meets the requirements of radiation protection. Compared with other extraction methods, the instrument outlay and the required working time are small. The total error of the method is below 5 percent

  3. Tunnel splitting for a high-spin molecule in an in-plane field

    Science.gov (United States)

    Zhu, Jia-Lin

    2000-08-01

    Direction and strength effects of a magnetic field on the ground-state tunnel splitting for a biaxial spin molecule with the model Hamiltonian H = k1Sz2 + k2Sy2- gµBHzSz- gµBHySy have been investigated within a continuous-spin approach including the Wess-Zumino-Berry term. The topological oscillation and the non-Kramers freezing indicated in the approach are in agreement with those observed in a recent experiment on Fe8 molecular nanomagnets. The behaviour of tunnel splitting with multiple orbits induced by strong fields has been revealed clearly.

  4. The electronic structure and ferromagnetism of TM (TM=V, Cr, and Mn)-doped BN(5, 5) nanotube: A first-principles study

    International Nuclear Information System (INIS)

    He, K.H.; Zheng, G.; Chen, G.; Wan, M.; Ji, G.F.

    2008-01-01

    We study the electronic structure and ferromagnetism of V-, Cr-, and Mn-doped single-wall BN(5, 5) nanotube by using polarized spin calculations within first principles. The optimized structures show that the transition-metal atoms move outwards and the calculated electronic properties demonstrate that the isolated V-, Cr-, and Mn-doped BN(5, 5) nanotubes show half-metallicity. The total ferromagnetic moments are 2μ B , 3.02μ B , and 3.98μ B for V-, Cr-, and Mn-doped BN(5, 5), respectively. The study suggests that such transition-metal (TM)-doped nanotubes may be useful in spintronics and nanomagnets

  5. Spin-orbit driven ferromagnetic resonance: a nanoscale magnetic characterisation technique

    Czech Academy of Sciences Publication Activity Database

    Fang, D.; Kurebayashi, H.; Wunderlich, Joerg; Výborný, Karel; Zarbo, Liviu; Campion, R. P.; Casiraghi, A.; Gallagher, B. L.; Jungwirth, Tomáš; Ferguson, A.J.

    2011-01-01

    Roč. 6, č. 7 (2011), s. 413-417 ISSN 1748-3387 R&D Projects: GA AV ČR KAN400100652; GA MŠk LC510; GA AV ČR KJB100100802; GA MŠk(CZ) 7E08087 EU Projects: European Commission(XE) 214499 - NAMASTE; European Commission(XE) 215368 - SemiSpinNet Grant - others:AV ČR(CZ) AP0801 Program:Akademická prémie - Praemium Academiae Institutional research plan: CEZ:AV0Z10100521 Keywords : ferromagnetic resonance * spin-orbit coupling * nanomagnets Subject RIV: BM - Solid Matter Physics ; Magnet ism Impact factor: 27.270, year: 2011

  6. Chirality effect on nearly half-metallic properties in systematic endo-doping of 3d transition metals of narrow carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Malehmir, M.; Khoshnevisan, B., E-mail: b.khosh@kashanu.ac.ir

    2016-10-20

    Spin polarized density functional calculations were employed to study chirality effect on electronic and magnetic properties of 3d transition metals (TMs) endo-doped co-diameter (∼7 Å) narrow (5,5) and (9,0) single walled carbon nanotubes (CNTs). Various magnetizations up to ∼6μ{sub B} was obtained for different 3dTM-CNT systems (recall that the magnetization of fcc structure cobalt is ∼1.6μ{sub B}). In addition nearly half-metallic magnetic behavior has been observed for the most of considered systems. These results would be useful for spintronic and nano-magnetic technology.

  7. High-Speed Non-Volatile Optical Memory: Achievements and Challenges

    Directory of Open Access Journals (Sweden)

    Vadym Zayets

    2017-01-01

    Full Text Available We have proposed, fabricated, and studied a new design of a high-speed optical non-volatile memory. The recoding mechanism of the proposed memory utilizes a magnetization reversal of a nanomagnet by a spin-polarized photocurrent. It was shown experimentally that the operational speed of this memory may be extremely fast above 1 TBit/s. The challenges to realize both a high-speed recording and a high-speed reading are discussed. The memory is compact, integratable, and compatible with present semiconductor technology. If realized, it will advance data processing and computing technology towards a faster operation speed.

  8. Quantum Spin Stabilized Magnetic Levitation

    Science.gov (United States)

    Rusconi, C. C.; Pöchhacker, V.; Kustura, K.; Cirac, J. I.; Romero-Isart, O.

    2017-10-01

    We theoretically show that, despite Earnshaw's theorem, a nonrotating single magnetic domain nanoparticle can be stably levitated in an external static magnetic field. The stabilization relies on the quantum spin origin of magnetization, namely, the gyromagnetic effect. We predict the existence of two stable phases related to the Einstein-de Haas effect and the Larmor precession. At a stable point, we derive a quadratic Hamiltonian that describes the quantum fluctuations of the degrees of freedom of the system. We show that, in the absence of thermal fluctuations, the quantum state of the nanomagnet at the equilibrium point contains entanglement and squeezing.

  9. Nanoscale magnetic field mapping with a single spin scanning probe magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Rondin, L.; Tetienne, J.-P.; Spinicelli, P.; Roch, J.-F.; Jacques, V. [Laboratoire de Photonique Quantique et Moleculaire, Ecole Normale Superieure de Cachan and CNRS UMR 8537, 94235 Cachan Cedex (France); Dal Savio, C.; Karrai, K. [Attocube systems AG, Koeniginstrasse 11A RGB, Munich 80539 (Germany); Dantelle, G. [Laboratoire de Physique de la Matiere Condensee, Ecole Polytechnique and CNRS UMR 7643, 91128 Palaiseau (France); Thiaville, A.; Rohart, S. [Laboratoire de Physique des Solides, Universite Paris-Sud and CNRS UMR 8502, 91405 Orsay (France)

    2012-04-09

    We demonstrate quantitative magnetic field mapping with nanoscale resolution, by applying a lock-in technique on the electron spin resonance frequency of a single nitrogen-vacancy defect placed at the apex of an atomic force microscope tip. In addition, we report an all-optical magnetic imaging technique which is sensitive to large off-axis magnetic fields, thus extending the operation range of diamond-based magnetometry. Both techniques are illustrated by using a magnetic hard disk as a test sample. Owing to the non-perturbing and quantitative nature of the magnetic probe, this work should open up numerous perspectives in nanomagnetism and spintronics.

  10. Radiation dose determines the method for quantification of DNA double strand breaks

    International Nuclear Information System (INIS)

    Bulat, Tanja; Keta, Olitija; Korićanac, Lela; Žakula, Jelena; Petrović, Ivan; Ristić-Fira, Aleksandra; Todorović, Danijela

    2016-01-01

    Ionizing radiation induces DNA double strand breaks (DSBs) that trigger phosphorylation of the histone protein H2AX (γH2AX). Immunofluorescent staining visualizes formation of γH2AX foci, allowing their quantification. This method, as opposed to Western blot assay and Flow cytometry, provides more accurate analysis, by showing exact position and intensity of fluorescent signal in each single cell. In practice there are problems in quantification of γH2AX. This paper is based on two issues: the determination of which technique should be applied concerning the radiation dose, and how to analyze fluorescent microscopy images obtained by different microscopes. HTB140 melanoma cells were exposed to γ-rays, in the dose range from 1 to 16 Gy. Radiation effects on the DNA level were analyzed at different time intervals after irradiation by Western blot analysis and immunofluorescence microscopy. Immunochemically stained cells were visualized with two types of microscopes: AxioVision (Zeiss, Germany) microscope, comprising an ApoTome software, and AxioImagerA1 microscope (Zeiss, Germany). Obtained results show that the level of γH2AX is time and dose dependent. Immunofluorescence microscopy provided better detection of DSBs for lower irradiation doses, while Western blot analysis was more reliable for higher irradiation doses. AxioVision microscope containing ApoTome software was more suitable for the detection of γH2AX foci. (author)

  11. Intraoperative Optical Coherence Tomography Using the RESCAN 700: Preliminary Results in Collagen Crosslinking.

    Science.gov (United States)

    Pahuja, Natasha; Shetty, Rohit; Jayadev, Chaitra; Nuijts, Rudy; Hedge, Bharath; Arora, Vishal

    2015-01-01

    To compare the penetration of riboflavin using a microscope-integrated real time spectral domain optical coherence tomography (ZEISS OPMI LUMERA 700 and ZEISS RESCAN 700) in keratoconus patients undergoing accelerated collagen crosslinking (ACXL) between epithelium on (epi-on) and epithelium off (epi-off). Intraoperative images were obtained during each of the procedures. Seven keratoconus patients underwent epi-on ACXL and four underwent epi-off ACXL. A software tool was developed using Microsoft.NET and Open Computer Vision (OpenCV) libraries for image analysis. Pre- and postprocedure images were analyzed for changes in the corneal hyperreflectance pattern as a measure of the depth of riboflavin penetration. The mean corneal hyperreflectance in the epi-on group was 12.97 ± 1.49 gray scale units (GSU) before instillation of riboflavin and 14.46 ± 2.09 GSU after AXCL (P = 0.019) while in the epi-off group it was 11.43 ± 2.68 GSU and 16.98 ± 8.49 GSU, respectively (P = 0.002). The average depth of the band of hyperreflectance in the epi-on group was 149.39 ± 15.63 microns and in the epi-off group it was 191.04 ± 32.18 microns. This novel in vivo, real time imaging study demonstrates riboflavin penetration during epi-on and epi-off ACXL.

  12. Intraoperative Optical Coherence Tomography Using the RESCAN 700: Preliminary Results in Collagen Crosslinking

    Directory of Open Access Journals (Sweden)

    Natasha Pahuja

    2015-01-01

    Full Text Available Purpose. To compare the penetration of riboflavin using a microscope-integrated real time spectral domain optical coherence tomography (ZEISS OPMI LUMERA 700 and ZEISS RESCAN 700 in keratoconus patients undergoing accelerated collagen crosslinking (ACXL between epithelium on (epi-on and epithelium off (epi-off. Methods. Intraoperative images were obtained during each of the procedures. Seven keratoconus patients underwent epi-on ACXL and four underwent epi-off ACXL. A software tool was developed using Microsoft.NET and Open Computer Vision (OpenCV libraries for image analysis. Pre- and postprocedure images were analyzed for changes in the corneal hyperreflectance pattern as a measure of the depth of riboflavin penetration. Results. The mean corneal hyperreflectance in the epi-on group was 12.97 ± 1.49 gray scale units (GSU before instillation of riboflavin and 14.46 ± 2.09 GSU after AXCL (P = 0.019 while in the epi-off group it was 11.43 ± 2.68 GSU and 16.98 ± 8.49 GSU, respectively (P = 0.002. The average depth of the band of hyperreflectance in the epi-on group was 149.39 ± 15.63 microns and in the epi-off group it was 191.04 ± 32.18 microns. Conclusion. This novel in vivo, real time imaging study demonstrates riboflavin penetration during epi-on and epi-off ACXL.

  13. Effect of Intracytoplasmic Sperm Injection (ICSI on Mouse Embryos Preimplantational Development

    Directory of Open Access Journals (Sweden)

    Claudia Cârstea

    2012-05-01

    Full Text Available It is known that the in vitro culture (IVC of preimplantation embryos is associated with changes in gene expression. It is however, not known if the method of fertilization affects the global pattern of gene expression. We compared the development of mouse blastocysts produced by intracytoplasmic sperm injection (ICSI versus blastocysts fertilized in vivo and cultured in vitro from the zygote stage (IVC. At the end of cultivation (96 hrs for blastocyst stage embryos, expanded blastocysts of each group were randomly selected, and ICM and total cells number were differentially stained. The total cell number of blastocysts was estimated by counting the total number of nuclei using DAPI staining. Cell number for inner cell mass (ICM was estimated by counting the OCT4 (POU5FL positive cells. Digitally recombined, composite images were analyzed using the Zeiss Axion Vision software and Zeiss Apotome. All 5–10 optical sections were divided using a standard grid over each layer to count all. Comparing the total cells and the ICM cells number, it appears that each method of fertilization has a unique pattern development. The developmental rate and the total cell number of the blastocyst were significantly lower in ICSI versus in vivo fertilized embryos which affect the embryonic developmental rate and the total cell number of blastocysts.

  14. Radiation dose determines the method for quantification of DNA double strand breaks

    Energy Technology Data Exchange (ETDEWEB)

    Bulat, Tanja; Keta, Olitija; Korićanac, Lela; Žakula, Jelena; Petrović, Ivan; Ristić-Fira, Aleksandra [University of Belgrade, Vinča Institute of Nuclear Sciences, Belgrade (Serbia); Todorović, Danijela, E-mail: dtodorovic@medf.kg.ac.rs [University of Kragujevac, Faculty of Medical Sciences, Kragujevac (Serbia)

    2016-03-15

    Ionizing radiation induces DNA double strand breaks (DSBs) that trigger phosphorylation of the histone protein H2AX (γH2AX). Immunofluorescent staining visualizes formation of γH2AX foci, allowing their quantification. This method, as opposed to Western blot assay and Flow cytometry, provides more accurate analysis, by showing exact position and intensity of fluorescent signal in each single cell. In practice there are problems in quantification of γH2AX. This paper is based on two issues: the determination of which technique should be applied concerning the radiation dose, and how to analyze fluorescent microscopy images obtained by different microscopes. HTB140 melanoma cells were exposed to γ-rays, in the dose range from 1 to 16 Gy. Radiation effects on the DNA level were analyzed at different time intervals after irradiation by Western blot analysis and immunofluorescence microscopy. Immunochemically stained cells were visualized with two types of microscopes: AxioVision (Zeiss, Germany) microscope, comprising an ApoTome software, and AxioImagerA1 microscope (Zeiss, Germany). Obtained results show that the level of γH2AX is time and dose dependent. Immunofluorescence microscopy provided better detection of DSBs for lower irradiation doses, while Western blot analysis was more reliable for higher irradiation doses. AxioVision microscope containing ApoTome software was more suitable for the detection of γH2AX foci. (author)

  15. Magnetization reversal processes of single nanomagnets and their energy barrier

    International Nuclear Information System (INIS)

    Krone, P.; Makarov, D.; Albrecht, M.; Schrefl, T.; Suess, D.

    2010-01-01

    Micromagnetic simulations were performed to investigate the influence of geometry and magnetic anisotropy constant on energy barrier and magnetization reversal mechanism of individual bits important for the bit patterned media concept in magnetic data storage. It is shown that dependency of the energy barrier on magnetic and geometric properties of bits can be described by an analytical approach in the case of quasi-coherent magnetization rotation process. However, when the bit size exceeds a critical size, for which an incoherent magnetization reversal is preferred, the analytical approach becomes invalid and no self-consistent theory is available. By systematically investigating the influence of bit size on the magnetization reversal mode, it was found that the transition from quasi-coherent to incoherent magnetization reversal mode can still be described analytically if an activation volume is considered instead of the bit volume. In this case, the nucleation volume is an important parameter determining thermal stability of the bit. If the volume of the bit is larger than twice the activation volume, the energy barrier stays nearly constant; with further increase in bit size, no gain in thermal stability can be achieved.

  16. Multi-parameter optimization of a nanomagnetic system for spintronic applications

    International Nuclear Information System (INIS)

    Morales Meza, Mishel; Zubieta Rico, Pablo F.; Horley, Paul P.; Sukhov, Alexander; Vieira, Vítor R.

    2014-01-01

    Magnetic properties of nano-particles feature many interesting physical phenomena that are essentially important for the creation of a new generation of spin-electronic devices. The magnetic stability of the nano-particles can be improved by formation of ordered particle arrays, which should be optimized over several parameters. Here we report successful optimization regarding inter-particle distance and applied field frequency allowing to obtain about three-times reduction of coercivity of a particle array compared to that of a single particle, which opens new perspectives for development of new spintronic devices

  17. Multi-parameter optimization of a nanomagnetic system for spintronic applications

    Energy Technology Data Exchange (ETDEWEB)

    Morales Meza, Mishel [Centro de Investigación en Materiales Avanzados, S.C. (CIMAV), Chihuahua/Monterrey, 120 Avenida Miguel de Cervantes, 31109 Chihuahua (Mexico); Zubieta Rico, Pablo F. [Centro de Investigación en Materiales Avanzados, S.C. (CIMAV), Chihuahua/Monterrey, 120 Avenida Miguel de Cervantes, 31109 Chihuahua (Mexico); Centro de Investigación y de Estudios Avanzados del IPN (CINVESTAV) Querétaro, Libramiento Norponiente 2000, Fracc. Real de Juriquilla, 76230 Querétaro (Mexico); Horley, Paul P., E-mail: paul.horley@cimav.edu.mx [Centro de Investigación en Materiales Avanzados, S.C. (CIMAV), Chihuahua/Monterrey, 120 Avenida Miguel de Cervantes, 31109 Chihuahua (Mexico); Sukhov, Alexander [Institut für Physik, Martin-Luther Universität Halle-Wittenberg, 06120 Halle (Saale) (Germany); Vieira, Vítor R. [Centro de Física das Interacções Fundamentais (CFIF), Instituto Superior Técnico, Universidade Técnica de Lisboa, Avenida Rovisco Pais, 1049-001 Lisbon (Portugal)

    2014-11-15

    Magnetic properties of nano-particles feature many interesting physical phenomena that are essentially important for the creation of a new generation of spin-electronic devices. The magnetic stability of the nano-particles can be improved by formation of ordered particle arrays, which should be optimized over several parameters. Here we report successful optimization regarding inter-particle distance and applied field frequency allowing to obtain about three-times reduction of coercivity of a particle array compared to that of a single particle, which opens new perspectives for development of new spintronic devices.

  18. Emergent 1/f noise in systems of oscillating nanomagnetic dots

    Science.gov (United States)

    Costanzi, Barry Nicholas

    No one makes it this far alone, and I am no exception; here I offer my thanks and gratitude to the many individuals who have helped me make it to where I am today. First and foremost, my adviser Dan Dahlberg. Dan's committment to his students above all else shows in both his advisory style, and his being a strong advocate for his students above all others. His advisement struck the perfect balance of offering direction while still allowing me to come into my own as an independent experimentalist, and really feel that I owned the work I did in the lab, embracing Herb Broida's decree (that was posted all over the lab) to make mistakes as quickly as possible to learn as quickly as possible. He also was always willing to go to bat for students over any University issue; knowing Dan was always in my corner was a huge help many times over. The other graduate students in the Dahlberg lab{Tanner and Feng for showing me the ropes in my early days in the lab, Dan E and Bern for composing the other two- thirds of `The St. Olaf Mafia" and being both imcomparably helpful peers, and great inspirations for the scientist I aspired to be, Dave for his unquenchable enthusiasm for grad school in the face of my increasing jadedness, and for being an unbelievably quick learner and indispensible lab mate, and James and Ben for injecting yet more new life into the lab, to carry on the maximization of JP products. Abstract not available.

  19. Studies on The Mechanism of The Microfilarial Periodicity(FN-4) : Studies on the essential feature of the autofluorescent substance(s) in the nocturnalmicronlariae (B)

    OpenAIRE

    真喜志, 金造; Makaishi, Kinzo; 琉球大学医学部第一内科学教室

    1981-01-01

    1. The night specimens of Mf. immitis emitted significantly more photons in 5seconds,excited by near 400nm, than those emitted from the daytime specimens. 2. Laser-Raman analysis detected in Mf. immitis the presence of Vitamin A, showing prominent Raman line near 1600cm-1, just samely with that of authentic V. A palmitate. 3. The similarity to rhodopsin and its intermediates was pursued. Microscopic fluorescence spectra, taken using UMSP-1 Zeiss, equipped with a Farrand-fluorescenee recorder,...

  20. Bursting Smoke as an Infrared Countermeasure

    OpenAIRE

    Amarjit Singh; P. J. Kamale; S. A. Joshi; L. K. Bankar

    1998-01-01

    This paper describes the experimental setup for the evaluation of bursting smoke for anti-infrared role using SR-5000 spectroradiometer and a source of IR radiation (8-13 micrometer) using cadmium-mercury-telluride (CMI) detector cooled by liquid nitrogen. The particle size and shape of the powders used in the bursting smokes were determined microscopically using Carl Zeiss Jena Neophot- 21. Highest attenuation of 97 -lOO percent was produced for about 12 s using a mixture of bronze fl...

  1. Novel chitosan coated magnetic nanocarriers for the targeted Diclofenac delivery.

    Science.gov (United States)

    Agotegaray, Mariela; Palma, Santiago; Lassalle, Verónica

    2014-05-01

    New magnetic devices consisting of magnetite functionalized with oleic acid and chitosan have been synthesized and employed to the loading of Diclofenac as potential tool for treatment of targeted inflammatory diseases. Magnetic loaded and un-loaded nanoparticles have been thoroughly characterized by infrared spectroscopy, transmission electron microscopy, determination of hydrodynamic diameter by Dynamic light scattering and zeta potential measurements at different pH conditions. A study of the release of Diclofenac has been performed in vitro and available mathematical models have been used to determine the release kinetic. Both properties and release data reveal that this nanomagnetic platform would be suitable for in vivo assays.

  2. Critical analysis and remedy of switching failures in straintronic logic using Bennett clocking in the presence of thermal fluctuations

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Kuntal, E-mail: royk@purdue.edu [School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907 (United States)

    2014-01-06

    Straintronic logic is a promising platform for beyond Moore's law computing. Using Bennett clocking mechanism, information can propagate through an array of strain-mediated multiferroic nanomagnets, exploiting the dipolar coupling between the magnets without having to physically interconnect them. Here, we perform a critical analysis of switching failures, i.e., error in information propagation due to thermal fluctuations through a chain of such straintronic devices. We solved stochastic Landau-Lifshitz-Gilbert equation considering room-temperature thermal perturbations and show that magnetization switching may fail due to inherent magnetization dynamics accompanied by thermally broadened switching delay distribution. Avenues available to circumvent such issue are proposed.

  3. Magnetic Nanostructures Spin Dynamics and Spin Transport

    CERN Document Server

    Farle, Michael

    2013-01-01

    Nanomagnetism and spintronics is a rapidly expanding and increasingly important field of research with many applications already on the market and many more to be expected in the near future. This field started in the mid-1980s with the discovery of the GMR effect, recently awarded with the Nobel prize to Albert Fert and Peter Grünberg. The present volume covers the most important and most timely aspects of magnetic heterostructures, including spin torque effects, spin injection, spin transport, spin fluctuations, proximity effects, and electrical control of spin valves. The chapters are written by internationally recognized experts in their respective fields and provide an overview of the latest status.

  4. Magnetization Reversal of Nanoscale Islands: How Size and Shape Affect the Arrhenius Prefactor

    Science.gov (United States)

    Krause, S.; Herzog, G.; Stapelfeldt, T.; Berbil-Bautista, L.; Bode, M.; Vedmedenko, E. Y.; Wiesendanger, R.

    2009-09-01

    The thermal switching behavior of individual in-plane magnetized Fe/W(110) nanoislands is investigated by a combined study of variable-temperature spin-polarized scanning tunneling microscopy and Monte Carlo simulations. Even for islands consisting of less than 100 atoms the magnetization reversal takes place via nucleation and propagation. The Arrhenius prefactor is found to strongly depend on the individual island size and shape, and based on the experimental results a simple model is developed to describe the magnetization reversal in terms of metastable states. Complementary Monte Carlo simulations confirm the model and provide new insight into the microscopic processes involved in magnetization reversal of smallest nanomagnets.

  5. Origin of second-order transverse magnetic anisotropy in Mn12-acetate

    International Nuclear Information System (INIS)

    Cornia, A.; Sessoli, R.; Sorace, L.; Gatteschi, D.; Barra, A. L.; Daiguebonne, C.

    2002-01-01

    The symmetry breaking effects for quantum tunneling of the magnetization in Mn 12 -acetate, a molecular nanomagnet, represent an open problem. We present structural evidence that the disorder of the acetic acid of crystallization induces sizable distortion of the Mn(III) sites, giving rise to six different isomers. Four isomers have symmetry lower than tetragonal and a nonzero second-order transverse magnetic anisotropy, which has been evaluated using a ligand field approach. The result of the calculation leads to an improved simulation of electron paramagnetic resonance spectra and justifies the tunnel splitting distribution derived from the field sweep rate dependence of the hysteresis loops

  6. Iron filled carbon nanotubes as novel monopole-like sensors for quantitative magnetic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wolny, F; Muehl, T; Weissker, U; Lipert, K; Schumann, J; Leonhardt, A; Buechner, B, E-mail: f.wolny@ifw-dresden.de, E-mail: t.muehl@ifw-dresden.de [Leibniz Institute for Solid State and Materials Research (IFW) Dresden, Helmholtzstrasse 20, 01069 Dresden (Germany)

    2010-10-29

    We present a novel ultrahigh stability sensor for quantitative magnetic force microscopy (MFM) based on an iron filled carbon nanotube. In contrast to the complex magnetic structure of conventional MFM probes, this sensor constitutes a nanomagnet with defined properties. The long iron nanowire can be regarded as an extended dipole of which only the monopole close to the sample surface is involved in the imaging process. We demonstrate its potential for high resolution imaging. Moreover, we present an easy routine to determine its monopole moment and prove that this calibration, unlike other approaches, is universally applicable. For the first time this enables straightforward quantitative MFM measurements.

  7. Fabrication of High Energy Density Tin/Carbon Anode Using Reduction Expansion Synthesis and Aerosol Through Plasma Techniques

    Science.gov (United States)

    2017-03-01

    his assistance with the analysis of samples using the TEM, as well as teaching me the safe use of XRD and SEM. Special thanks also go out to Ryan Adams...from the energy and construct a greyscale image for display. Figure 19. Zeiss NEON 40 SEM. Setup of SEM. Left: SEM and movement of stage using...delithiation cycling,” J. Electrochem. Soc., vol. 161, no. 11, pp. 3019– 3024, Jun. 2014. [20] P. L. Walker, Chemistry and Physics of Carbon: A Series of

  8. Fundus auto fluorescence and spectral domain ocular coherence tomography in the early detection of chloroquine retinopathy

    Directory of Open Access Journals (Sweden)

    Megan B. Goodman

    2015-08-01

    Full Text Available Purpose: To determine the sensitivity of spectral domain ocular coherence tomography (SD-OCT and fundus auto fluorescence (FAF images as a screening test to detect early changes in the retina prior to the onset of chloroquine retinopathy. Method: The study was conducted using patients taking chloroquine (CQ, referred by the Rheumatology Department to the Ophthalmology Department at Tygerberg Academic Hospital. Group A consisted of 59 patients on CQ for less than 5 years, and Group B consisted of 53 patients on CQ for more than 5 years. A 200 × 200 macula thickness map, 5-line raster SD-OCT on a Carl Zeiss Meditec Cirrus HD-OCT and FAF images on a Carl Zeiss Meditec Visucam 500 were recorded for 223 eyes. Images were reviewed independently, and then those of Groups A and B compared. Results: There were no statistically significant differences between Groups A and B. The criteria included the internal limiting membrane and the retinal pigment epithelium (ILM-RPE thickness, interdigitation zone integrity (p = 0.891, df = 1, χ² = 0.1876, ellipsoid zone integrity (p = 0.095, df = 2, χ² = 4.699 and FAF image irregularities (p = 0.479, df = 1, χ²= 4995978. Conclusion: The inclusion of SD-OCT and FAF as objective tests into the prescribed screening guidelines does not appear to simplify the detection of subclinical injury in patients on chloroquine treatment.

  9. Low-cost, smartphone based frequency doubling technology visual field testing using virtual reality (Conference Presentation)

    Science.gov (United States)

    Alawa, Karam A.; Sayed, Mohamed; Arboleda, Alejandro; Durkee, Heather A.; Aguilar, Mariela C.; Lee, Richard K.

    2017-02-01

    Glaucoma is the leading cause of irreversible blindness worldwide. Due to its wide prevalence, effective screening tools are necessary. The purpose of this project is to design and evaluate a system that enables portable, cost effective, smartphone based visual field screening based on frequency doubling technology. The system is comprised of an Android smartphone to display frequency doubling stimuli and handle processing, a Bluetooth remote for user input, and a virtual reality headset to simulate the exam. The LG Nexus 5 smartphone and BoboVR Z3 virtual reality headset were used for their screen size and lens configuration, respectively. The system is capable of running the C-20, N-30, 24-2, and 30-2 testing patterns. Unlike the existing system, the smartphone FDT tests both eyes concurrently by showing the same background to both eyes but only displaying the stimulus to one eye at a time. Both the Humphrey Zeiss FDT and the smartphone FDT were tested on five subjects without a history of ocular disease with the C-20 testing pattern. The smartphone FDT successfully produced frequency doubling stimuli at the correct spatial and temporal frequency. Subjects could not tell which eye was being tested. All five subjects preferred the smartphone FDT to the Humphrey Zeiss FDT due to comfort and ease of use. The smartphone FDT is a low-cost, portable visual field screening device that can be used as a screening tool for glaucoma.

  10. PERFLUOROCARBON LIQUIDS' ABILITY TO PROTECT THE MACULA FROM INTRAOCULAR DROPPING OF METALLIC FOREIGN BODIES: A Model Eye Study.

    Science.gov (United States)

    Shah, Chirag M; Gentile, Ronald C; Mehta, Mitul C

    2016-07-01

    To examine the utility of perfluoro-n-octane (PFO) in balanced salt solution (BSS) to shield the macula from the impact of dropped metallic intraocular foreign bodies (IOFBs) by modeling scenarios in which they may fall during surgical removal. Model eyes were filled with various fluid mixtures (Group 1: 10% PFO/90% BSS; Group 2: 100% BSS; Group 3: 100% PFO; Group 4: 10% PFO/90% air; Group 5: 10% BSS/90% air). In Groups 1, 4, and 5, the 10% fluid volume covered the theoretical macula. For each fluid mixture, up to 30 IOFB drop scenarios were performed for each of the 5 sample IOFBs from 3 locations. Trajectories were recorded using a camera attached to a Zeiss operating microscope (Carl Zeiss, Jena, Germany). The percentages of IOFBs impacting the macula were calculated and Fisher exact test was used to assess differences. In Group 1, 93% (417/450) of the dropped IOFBs were deflected by the PFO-BSS interface compared with 0% (0/500) in Groups 2, 3, 4, and 5 (P macula in 30% of tests when dropped from the superior posterior segment (P < 0.01), all other IOFBs (2.8-13.4 mg) were deflected by the PFO-BSS interface in 100% of Group 1 drops (P < 0.01). As demonstrated by these simulations, the PFO-BSS interface can deflect IOFBs dropped during surgery in a wide range of scenarios, especially when the IOFB is of lower mass.

  11. Image quality characteristics of a novel colour scanning digital ophthalmoscope (SDO) compared with fundus photography.

    Science.gov (United States)

    Strauss, Rupert W; Krieglstein, Tina R; Priglinger, Siegfried G; Reis, Werner; Ulbig, Michael W; Kampik, Anselm; Neubauer, Aljoscha S

    2007-11-01

    To establish a set of quality parameters for grading image quality and apply those to evaluate the fundus image quality obtained by a new scanning digital ophthalmoscope (SDO) compared with standard slide photography. On visual analogue scales a total of eight image characteristics were defined: overall quality, contrast, colour brilliance, focus (sharpness), resolution and details, noise, artefacts and validity of clinical assessment. Grading was repeated after 4 months to assess repeatability. Fundus images of 23 patients imaged digitally by SDO and by Zeiss 450FF fundus camera using Kodak film were graded side-by-side by three graders. Lens opacity was quantified with the Interzeag Lens Opacity Meter 701. For all of the eight scales of image quality, good repeatability within the graders (mean Kendall's W 0.69) was obtained after 4 months. Inter-grader agreement ranged between 0.31 and 0.66. Despite the SDO's limited nominal image resolution of 720 x 576 pixels, the Zeiss FF 450 camera performed better in only two of the subscales - noise (p = 0.001) and artefacts (p = 0.01). Lens opacities significantly influenced only the two subscales 'resolution' and 'details', which deteriorated with increasing media opacities for both imaging systems. Distinct scales to grade image characteristics of different origin were developed and validated. Overall SDO digital imaging was found to provide fundus pictures of a similarly high level of quality as expert photography on slides.

  12. Confocal scanning microscopy

    DEFF Research Database (Denmark)

    Bariani, Paolo

    This report is based on a metrological investigation on confocal microscopy technique carried out by Uffe Rolf Arlø Theilade and Paolo Bariani. The purpose of the experimental activity was twofold a metrological instrument characterization and application to assessment of rough PP injection moulded...... replicated topography. Confocal microscopy is seen to be a promising technique in metrology of microstructures. Some limitations with respect to surface metrology were found during the experiments. The experiments were carried out using a Zeiss LSM 5 Pascal microscope owned by the Danish Polymer Centre...

  13. Observing Fluorescent Probes in Living Cells using a Low-Cost LED Flashlight Retrofitted to a Common Vintage Light Microscope

    Directory of Open Access Journals (Sweden)

    G. A. Babbitt

    2013-03-01

    Full Text Available While the application of molecular biological techniques based upon fluorescent probes has rapidly expanded over recent decades, the equipment cost of fluorescent microscopy has largely prevented its adoption in the college and high school classroom. We offer a simple solution to this problem by describing in detail how to build with simple tools, a fluorescent microscope using a common brand of colored LED flashlights and second-hand components of vintage Nikon microscopes. This extremely low cost solution is qualitatively compared to an expensive modern Zeiss system.

  14. Five HSFA telescopes and spectrographs - family silver or Greek gift?

    Science.gov (United States)

    Kotrč, P.

    2010-12-01

    A quarter-century ago five horizontal solar telescopes were delivered to Czechoslovakia from the Carl Zeiss Jena Company. Two of them have been installed in Ondrejov and one each in Hurbanovo, and Stará Lesná, with the last one reaching a mountain observatory near Alma Ata, Kazakhstan. The paper summarizes the brief history and characteristics of the instruments, different ways of their use, and realistic plans for their development. The users of the equipment received a dozen questions. The answers help us understand the importance of these instruments for the individual observatories.

  15. DOLOČITEV POVRŠINSKE NAPETOSTI Z METODO KAPILARNEGA DVIGA DVOFAZNIH SISTEMOV

    OpenAIRE

    Kravanja, Gregor

    2014-01-01

    Namen magistrske naloge je bil postavitev merilne naprave in razvoj nove metode merjenja površinske napetosti s kapilarnim dvigom dvofaznih sistemov v okolici kritične točke. Za pridobitev natančnih in primerljivih meritev je bilo potrebno poznati natančni notranji premer tankih kapilar. Določili smo ga z metodo laserskega tipanja na nemški koordinatni merilni napravi ZEISS tipa UMC-850 s pomočjo merilne programske opreme CALYPSO 5.1.4. Za merjenje ravnotežne višine smo uporabili računalniški...

  16. Using laser technological unit ALTI "Karavella" for precision components of IEP production

    Science.gov (United States)

    Labin, N. A.; Chursin, A. D.; Paramonov, V. S.; Klimenko, V. I.; Paramonova, G. M.; Kolokolov, I. S.; Vinogradov, K. Y.; Betina, L. L.; Bulychev, N. A.; Dyakov, Yu. A.; Zakharyan, R. A.; Kazaryan, M. A.; Koshelev, K. K.; Kosheleva, O. K.; Grigoryants, A. G.; Shiganov, I. N.; Krasovskii, V. I.; Sachkov, V. I.; Plyaka, P. S.; Feofanov, I. N.; Chen, C.

    2015-12-01

    The paper revealed the using of industrial production equipment ALTI "Karavella-1", "Karavella-1M", "Karavella-2" and "Karavella-2M" precision components of IEP production [1-4]. The basis for the ALTI using in the IEP have become the positive results of research and development of technologies of foil (0.01-0.2 mm) and thin sheets (0.3-1 mm) materials micromachining by pulsed radiation CVL [5, 6]. To assess the micromachining quality and precision the measuring optical microscope (UHL VMM200), projection microscope (Mitutoyo PV5100) and Carl Zeiss microscope were used.

  17. Microstructure characterization of ceramic nuclear fuel

    International Nuclear Information System (INIS)

    Boehmert, J.; Gaessner, W.

    1984-08-01

    A system of characterizing methods is described based on quantitative ceramographic methods. This system is applicable in quality assurance of UO 2 nuclear fuel in small-scale production and for determining microstructural parameters in scientific investigations. The system is based essentially on the measuring of microstructural parameters by the methods of linear analysis by the VEB Carl Zeiss Jena EPIQUANT mechanical optical microstructural analyzer. It is completed by measuring the pore size using automatic the television analyzer QTM. Before the quantitative microstructural characterization, in each case the morphology of the structure is estimated qualitatively. (author)

  18. The Possibility of Quantum Deflagration in the Fe8 Nano-Magnet

    Science.gov (United States)

    Leviant, Tom; Zeldov, Eli; Myasoedov, Yuri; Keren, Amit

    2014-03-01

    We report spatially resolved, time-dependent, magnetization reversal measurements of Fe8 single crystals using a microscopic Hall bar array. We found that in some samples the molecules reverse their spin direction at the resonance field in the form of deflagration. The deflagration front velocity is on the order of 1 m/sec and sensitive to field gradients and sweep rates. We discuss the possibility that this slow deflagration can be explained by flipping rates determined by the tunnel splitting only, with no over-the-barrier motion.

  19. New insights into nano-magnetism by spin-polarized scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Sander, Dirk, E-mail: sander@mpi-halle.de [Max-Planck-Institut für Mikrostrukturphysik, Weinberg 2, D-06120 Halle/Saale (Germany); Oka, Hirofumi; Corbetta, Marco; Stepanyuk, Valeri; Kirschner, Jürgen [Max-Planck-Institut für Mikrostrukturphysik, Weinberg 2, D-06120 Halle/Saale (Germany)

    2013-08-15

    Highlights: ► We measure the magnetization reversal of individual nm small Co island by spin-STM. ► We identify an inhomogeneous magnetic anisotropy within a single Co island. ► The magnetic anisotropy near the rim is negligible as compared to 0.148 meV/atom at the island center. ► A crossover of the magnetization reversal from an exchange-spring behavior to domain wall formation is suggested. ► The impact of the observed spatial variation of the spin-dependent electronic properties on reversal is discussed. -- Abstract: We study the magnetization reversal and the position dependence of the spin-dependent electronic properties of nm small bilayer Co islands on Cu(1 1 1) by spin-polarized scanning tunneling microscopy in magnetic fields at low temperatures of 8 K. The analysis of the energy barrier of magnetization reversal from measurements of the switching field suggests a crossover of the magnetization reversal mode with increasing island size around 7500 atoms from exchange-spring behavior to domain wall formation. The quantitative analysis of the island size dependence of the energy barrier indicates an inhomogeneous magnetic anisotropy of the island. The island rim is magnetically soft, whereas the center shows a pronounced effective anisotropy of 0.148 meV/atom. We speculate that this inhomogeneity of the magnetic anisotropy might be a consequence of the spatial dependence of the spin-dependent electronic properties. We measure a spin-polarization and a tunnel magneto resistance ratio of opposite sign at the rim as compared to the island center.

  20. New insights into nano-magnetism by spin-polarized scanning tunneling microscopy

    International Nuclear Information System (INIS)

    Sander, Dirk; Oka, Hirofumi; Corbetta, Marco; Stepanyuk, Valeri; Kirschner, Jürgen

    2013-01-01

    Highlights: ► We measure the magnetization reversal of individual nm small Co island by spin-STM. ► We identify an inhomogeneous magnetic anisotropy within a single Co island. ► The magnetic anisotropy near the rim is negligible as compared to 0.148 meV/atom at the island center. ► A crossover of the magnetization reversal from an exchange-spring behavior to domain wall formation is suggested. ► The impact of the observed spatial variation of the spin-dependent electronic properties on reversal is discussed. -- Abstract: We study the magnetization reversal and the position dependence of the spin-dependent electronic properties of nm small bilayer Co islands on Cu(1 1 1) by spin-polarized scanning tunneling microscopy in magnetic fields at low temperatures of 8 K. The analysis of the energy barrier of magnetization reversal from measurements of the switching field suggests a crossover of the magnetization reversal mode with increasing island size around 7500 atoms from exchange-spring behavior to domain wall formation. The quantitative analysis of the island size dependence of the energy barrier indicates an inhomogeneous magnetic anisotropy of the island. The island rim is magnetically soft, whereas the center shows a pronounced effective anisotropy of 0.148 meV/atom. We speculate that this inhomogeneity of the magnetic anisotropy might be a consequence of the spatial dependence of the spin-dependent electronic properties. We measure a spin-polarization and a tunnel magneto resistance ratio of opposite sign at the rim as compared to the island center

  1. Effect of resistance feedback on spin torque-induced switching of nanomagnets

    International Nuclear Information System (INIS)

    Garzon, Samir; Webb, Richard A.; Covington, Mark; Kaka, Shehzaad; Crawford, Thomas M.

    2009-01-01

    In large magnetoresistance devices spin torque-induced changes in resistance can produce GHz current and voltage oscillations which can affect magnetization reversal. In addition, capacitive shunting in large resistance devices can further reduce the current, adversely affecting spin torque switching. Here, we simultaneously solve the Landau-Lifshitz-Gilbert equation with spin torque and the transmission line telegrapher's equations to study the effects of resistance feedback and capacitance on magnetization reversal of both spin valves and magnetic tunnel junctions. While for spin valves parallel (P) to anti-parallel (AP) switching is adversely affected by the resistance feedback due to saturation of the spin torque, in low resistance magnetic tunnel junctions P-AP switching is enhanced. We study the effect of resistance feedback on the switching time of magnetic tunnel junctions, and show that magnetization switching is only affected by capacitive shunting in the pF range.

  2. Ultra - Low - Power Asynchronous Processor and FPGA Design using Straintronics Nanomagnets

    Science.gov (United States)

    2013-05-01

    i‐th filter BW  The  coefficients   are  generated  inside  the  controller.  The  architecture  avoids  multipliers  and  shares  the  coefficients ...illustrated  in  Fig  25  –b.  i)  The  E‐field  causes  a  strain  in  PZT   leading  to a deformation S =  .  ii) Strain gets  transformed  to  free NM.  iii... PZT  is a parallel place capacitance while MTJ  is a variable resistance. This  is shown  in Fig  26. Shape anisotropy and uniaxial crystalline

  3. Energy efficient hybrid computing systems using spin devices

    Science.gov (United States)

    Sharad, Mrigank

    Emerging spin-devices like magnetic tunnel junctions (MTJ's), spin-valves and domain wall magnets (DWM) have opened new avenues for spin-based logic design. This work explored potential computing applications which can exploit such devices for higher energy-efficiency and performance. The proposed applications involve hybrid design schemes, where charge-based devices supplement the spin-devices, to gain large benefits at the system level. As an example, lateral spin valves (LSV) involve switching of nanomagnets using spin-polarized current injection through a metallic channel such as Cu. Such spin-torque based devices possess several interesting properties that can be exploited for ultra-low power computation. Analog characteristic of spin current facilitate non-Boolean computation like majority evaluation that can be used to model a neuron. The magneto-metallic neurons can operate at ultra-low terminal voltage of ˜20mV, thereby resulting in small computation power. Moreover, since nano-magnets inherently act as memory elements, these devices can facilitate integration of logic and memory in interesting ways. The spin based neurons can be integrated with CMOS and other emerging devices leading to different classes of neuromorphic/non-Von-Neumann architectures. The spin-based designs involve `mixed-mode' processing and hence can provide very compact and ultra-low energy solutions for complex computation blocks, both digital as well as analog. Such low-power, hybrid designs can be suitable for various data processing applications like cognitive computing, associative memory, and currentmode on-chip global interconnects. Simulation results for these applications based on device-circuit co-simulation framework predict more than ˜100x improvement in computation energy as compared to state of the art CMOS design, for optimal spin-device parameters.

  4. In situ transmission electron microscopy for magnetic nanostructures

    DEFF Research Database (Denmark)

    Ngo, Duc-The; Kuhn, Luise Theil

    2016-01-01

    Nanomagnetism is a subject of great interest because of both application and fundamental aspects in which understanding of the physical and electromagnetic structure of magnetic nanostructures is essential to explore the magnetic properties. Transmission electron microscopy (TEM) is a powerful tool...... that allows understanding of both physical structure and micromagnetic structure of the thin samples at nanoscale. Among TEM techniques, in situ TEM is the state-of-the-art approach for imaging such structures in dynamic experiments, reconstructing a real-time nanoscale picture of the properties......-structure correlation. This paper aims at reviewing and discussing in situ TEM magnetic imaging studies, including Lorentz microscopy and electron holography in TEM, applied to the research of magnetic nanostructures....

  5. Influence of Shape Anisotropy on Magnetization Dynamics Driven by Spin Hall Effect

    Directory of Open Access Journals (Sweden)

    X. G. Li

    2016-01-01

    Full Text Available As the lateral dimension of spin Hall effect based magnetic random-access memory (SHE-RAM devices is scaled down, shape anisotropy has varied influence on both the magnetic field and the current-driven switching characteristics. In this paper, we study such influences on elliptic film nanomagnets and theoretically investigate the switching characteristics for SHE-RAM element with in-plane magnetization. The analytical expressions for critical current density are presented and the results are compared with those obtained from macrospin and micromagnetic simulation. It is found that the key performance indicators for in-plane SHE-RAM, including thermal stability and spin torque efficiency, are highly geometry dependent and can be effectively improved by geometric design.

  6. The effect of surfactant addition on high-energy milling upon the magnetic properties and microstructure of the Pr-Fe-B HDDR magnetic powders

    International Nuclear Information System (INIS)

    Santos, P.B.; Silva, S.C.; Faria, R.N.; Takiishia, H.

    2010-01-01

    Nanomagnetic powders based on the composition Pr 12 Fe 65.9 Co 16 B 6 Nb 0.1 have been obtained from using (a) the hydrogenation, disproportionation, desorption and recombination (HDDR) process; (b) by varying of milling time and (c) with the addition of an oleic acid as a surfactant. The latter has been used to enhance milling condition by preventing the agglomeration of particles and hence to improve the intrinsic coercivity of the material. High-energy mechanical milling has been used to yield magnetic nanoparticles. Powders were characterized magnetically using vibrating sample magnetometer (VSM) and microstructurally by Scanning Electron Microscopy (SEM), Field Emission Gun SEM (FEG-SEM) and X-ray diffraction. (author)

  7. The First Homoleptic Complex of Seven-Coordinated Osmium: Synthesis and Crystallographical Evidence of Pentagonal Bipyramidal Polyhedron of Heptacyanoosmate(IV

    Directory of Open Access Journals (Sweden)

    Eugenia V. Peresypkina

    2016-08-01

    Full Text Available The ligand exchange in (n-Bu4N2OsIVCl6 (n-Bu4N = tetra-n-butylammonium leads to the formation of the osmium(IV heptacyanide, the first fully inorganic homoleptic complex of heptacoordinated osmium. The single-crystal X-ray diffraction (SC-XRD study reveals the pentagonal bipyramidal molecular structure of the [Os(CN7]3− anion. The latter being a diamagnetic analogue of the highly anisotropic paramagnetic synthon, [ReIV(CN7]3− can be used for the synthesis of the model heterometallic coordination compounds for the detailed study and simulation of the magnetic properties of the low-dimensional molecular nanomagnets involving 5d metal heptacyanides.

  8. The effect of surfactant addition on high-energy milling upon the magnetic properties and microstructure of the Pr-Fe-B HDDR magnetic powders; Efeito da adicao de surfactantes nas propriedades e microestrutura de pos magneticos a base de Pr-Fe-B obtidos via HDDR e moagem de alta energia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, P.B.; Silva, S.C.; Faria, R.N.; Takiishia, H., E-mail: pbsantos@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2010-07-01

    Nanomagnetic powders based on the composition Pr{sub 12}Fe{sub 65.9}Co{sub 16}B{sub 6}Nb{sub 0.1} have been obtained from using (a) the hydrogenation, disproportionation, desorption and recombination (HDDR) process; (b) by varying of milling time and (c) with the addition of an oleic acid as a surfactant. The latter has been used to enhance milling condition by preventing the agglomeration of particles and hence to improve the intrinsic coercivity of the material. High-energy mechanical milling has been used to yield magnetic nanoparticles. Powders were characterized magnetically using vibrating sample magnetometer (VSM) and microstructurally by Scanning Electron Microscopy (SEM), Field Emission Gun SEM (FEG-SEM) and X-ray diffraction. (author)

  9. Scanning laser polarimetry and spectral domain optical coherence tomography for the detection of retinal changes in Parkinson's disease.

    Science.gov (United States)

    Stemplewitz, Birthe; Keserü, Matthias; Bittersohl, Diana; Buhmann, Carsten; Skevas, Christos; Richard, Gisbert; Hassenstein, Andrea

    2015-12-01

    Whether retinal degeneration is part of the degenerative processes in patients with Parkinson's disease (PD) is still unclear. This cross-sectional study was undertaken to compare the retinal morphology of patients with PD and healthy controls using spectral domain optical coherence tomography (SD-OCT) and scanning laser polarimetry (SLP). Both eyes of patients with PD (n = 108) and healthy controls (n = 165) were examined using SD-OCT and SLP on the same day. Data on the thickness of the retinal nerve fibre layer (RNFL) of all quadrants and the macular area were acquired by OCT (Cirrus, Zeiss). The SLP device (Glaucoma diagnostics (GDx), Zeiss) measured the RNFL and calculated the nerve fibre index (NFI). All patients and probands were checked for concomitant ocular disorders by an ophthalmologist. Visual acuity, intraocular pressure (IOP), objective refraction and the anterior and posterior segment were assessed. Patients with PD showed a reduced macular volume and a reduced central subfield thickness in OCT examinations. The RNFL in the different quadrants did not differ significantly from that of controls. SLP data showed a reduced average RNFL thickness, a decreased thickness of the inferior quadrant and an increase of the NFI in patients with PD. PD may be associated with reduced thickness and volume of the macula and a reduced thickness of the RNFL in the inferior quadrant of the retina. Investigations using SD-OCT and SLP revealed distinct but significant differences between patients with PD and healthy controls. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. Efficacy and safety of multifocal intraocular lenses following cataract and refractive lens exchange: Metaanalysis of peer-reviewed publications.

    Science.gov (United States)

    Rosen, Emanuel; Alió, Jorge L; Dick, H Burkhard; Dell, Steven; Slade, Stephen

    2016-02-01

    We performed a metaanaysis of peer-reviewed studies involving implantation of a multifocal intraocular lens (IOL) in presbyopic patients with cataract or having refractive lens exchange (RLE). Previous reviews have considered the use of multifocal IOLs after cataract surgery but not after RLE, whereas greater insight might be gained from examining the full range of studies. Selected studies were examined to collate outcomes with monocular and binocular uncorrected distance, intermediate, and near visual acuity; spectacle independence; contrast sensitivity; visual symptoms; adverse events; and patient satisfaction. In 8797 eyes, the mean postoperative monocular uncorrected distance visual acuity (UDVA) was 0.05 logMAR ± 0.006 (SD) (Snellen equivalent 20/20(-3)). In 6334 patients, the mean binocular UDVA was 0.04 ± 0.00 logMAR (Snellen equivalent 20/20(-2)), with a mean spectacle independence of 80.1%. Monocular mean UDVA did not differ significantly between those who had a cataract procedure and those who had an RLE procedure. Neural adaptation to multifocality may vary among patients. Dr. Alió is a clinical research investigator for Hanita Lenses, Carl Zeiss Meditec AG, Topcon Medical Systems, Inc., Oculentis GmbH, and Akkolens International BV. Dr. Dell is a consultant to Bausch & Lomb and Abbott Medical Optics, Inc. Dr. Slade is a consultant to Alcon Surgical, Inc., Carl Zeiss Meditec AG, and Bausch & Lomb. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Comportamiento de la cromósfera solar en la línea H-alfa durante el período enero/05-agosto/06

    Science.gov (United States)

    Missio, H.; Davoli, D.; Aquilano, R.

    Using the instrument at Observatorio Astronómico Municipal de Rosario (OAMR), we analyze the solar chromospheric activity during the period January/05-August/06. The instrument is a Carl Zeiss refractor telescope of 150 mm aperture and 2250 mm of focal distance with a monochromatic filter in the H-alpha line. We take as proxy for the solar activity the area covered by chromospheric ``plages''. The measurements are done using photographic registers. We describe our technique and the results obtained. We observe a decrease of solar activity that corresponds to the end of cycle 23. FULL TEXT IN SPANISH

  12. Compilation of 1989 Annual Reports of the Navy ELF Communications System Ecological Monitoring Program. Volume 3. Tabs G, H

    Science.gov (United States)

    1990-08-01

    Regulus calendula ! Eastern Bluebird 1 0 2 1 0 0 0 0 0 0 Sialia sialis 3 Veery 0 0 20 18 17 25 1 0 2 0 Catharus fuscescens Swainson’s Thrush 0 0 0 2 0 0...Regulus satrapa3 Ruby-crowned -Kinglet 1 0 2 1 0 0 0 0 3 0 Regulus calendula Veery 1 0- 12 4 2 2 0- 3 0 0 Catharus fuscescens -Swainson’s Thrush 0 0- 0...calculations, andIspecies determinations was done at 1250X magnification on a Zeiss microscope equipped with phase contrast illumination and an oil

  13. Small-incision lenticule extraction (SMILE)

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    2016-01-01

    surgery was 0.07 ± 0.03 (logMAR). However, 12 eyes (1.6 %) lost 2 or more lines of CDVA from before surgery to 3 months postoperatively. Simultaneous treatment of up to 3.00 D of astigmatism was not associated with less predictable refractive outcomes. CONCLUSIONS: In the short term, SMILE seemed......PURPOSE: To study the outcomes of small-incision lenticule extraction (SMILE) for treatment of myopia and myopic astigmatism. METHODS: Retrospective study of patients treated for myopia or myopic astigmatism with SMILE, using a VisuMax(®) femtosecond laser (Carl Zeiss Meditec, Jena, Germany...

  14. The response of an individual vortex to local mechanical contact

    Science.gov (United States)

    Kremen, Anna; Wissberg, Shai; Shperber, Yishai; Kalisky, Beena

    2016-05-01

    Recently we reported a new way to manipulate vortices in thin superconducting films by local mechanical contact without magnetic field, current or altering the pinning landscape [1]. We use scanning superconducting interference device (SQUID) microscopy to image the vortices, and a piezo element to push the tip of a silicon chip into contact with the sample. As a result of the stress applied at the contact point, vortices in the proximity of the contact point change their location. Here we study the characteristics of this vortex manipulation, by following the response of individual vortices to single contact events. Mechanical manipulation of vortices provides local view of the interaction between strain and nanomagnetic objects, as well as controllable, effective, localized, and reproducible manipulation technique.

  15. Microscopic Origin of Interfacial Dzyaloshinskii-Moriya Interaction

    KAUST Repository

    Kim, Sanghoon

    2017-04-10

    Chiral spin textures at the interface between ferromagnetic and heavy nonmagnetic metals, such as Neel-type domain walls and skyrmions, have been studied intensively because of their great potential for future nanomagnetic devices. The Dyzaloshinskii-Moriya interaction (DMI) is an essential phenomenon for the formation of such chiral spin textures. In spite of recent theoretical progress aiming at understanding the microscopic origin of the DMI, an experimental investigation unravelling the physics at stake is still required. Here, we experimentally demonstrate the close correlation of the DMI with the anisotropy of the orbital magnetic moment and with the magnetic dipole moment of the ferromagnetic metal. The density functional theory and the tight-binding model calculations reveal that asymmetric electron occupation in orbitals gives rise to this correlation.

  16. Spin-wave interference patterns created by spin-torque nano-oscillators for memory and computation

    International Nuclear Information System (INIS)

    Macia, Ferran; Kent, Andrew D; Hoppensteadt, Frank C

    2011-01-01

    Magnetization dynamics in nanomagnets has attracted broad interest since it was predicted that a dc current flowing through a thin magnetic layer can create spin-wave excitations. These excitations are due to spin momentum transfer, a transfer of spin angular momentum between conduction electrons and the background magnetization, that enables new types of information processing. Here we show how arrays of spin-torque nano-oscillators can create propagating spin-wave interference patterns of use for memory and computation. Memristic transponders distributed on the thin film respond to threshold tunnel magnetoresistance values, thereby allowing spin-wave detection and creating new excitation patterns. We show how groups of transponders create resonant (reverberating) spin-wave interference patterns that may be used for polychronous wave computation and information storage.

  17. Functionalized nanoparticles for AMF-induced gene and drug delivery

    Science.gov (United States)

    Biswas, Souvik

    The properties and broad applications of nano-magnetic colloids have generated much interest in recent years. Specially, Fe3O4 nanoparticles have attracted a great deal of attention since their magnetic properties can be used for hyperthermia treatment or drug targeting. For example, enhanced levels of intracellular gene delivery can be achieved using Fe3O4 nano-vectors in the presence of an external magnetic field, a process known as 'magnetofection'. The low cytotoxicity, tunable particle size, ease of surface functionalization, and ability to generate thermal energy using an external alternating magnetic field (AMF) are properties have propelled Fe3O4 research to the forefront of nanoparticle research. The strategy of nanoparticle-mediated, AMF-induced heat generation has been used to effect intracellular hyperthermia. One application of this 'magnetic hyperthermia' is heat activated local delivery of a therapeutic effector (e.g.; drug or polynucleotide). This thesis describes the development of a magnetic nano-vector for AMF-induced, heat-activated pDNA and small molecule delivery. The use of heat-inducible vectors, such as heat shock protein ( hsp) genes, is a promising mode of gene therapy that would restrict gene expression to a local region by focusing a heat stimulus only at a target region. We thus aimed to design an Fe3O4 nanoparticle-mediated gene transfer vehicle for AMF-induced localized gene expression. We opted to use 'click' oximation techniques to assemble the magnetic gene transfer vector. Chapter 2 describes the synthesis, characterization, and transfection studies of the oxime ether lipid-based nano-magnetic vectors MLP and dMLP. The synthesis and characterization of a novel series of quaternary ammonium aminooxy reagents (2.1--2.4) is described. These cationic aminooxy compounds were loaded onto nanoparticles for ligation with carbonyl groups and also to impart a net positive charge on the nanoparticle surface. Our studies indicated that the

  18. Nuclear spin bath effects in molecular nanomagnets: Direct quantum mechanical simulations

    Science.gov (United States)

    Sinitsyn, N. A.; Dobrovitski, V. V.

    2004-11-01

    We investigate the influence of nuclear spins on the electronic spin tunneling in magnetic molecules such as Fe8 , focusing on the role of the spin diffusion in the nuclear spin bath. We simulate the quantum spin dynamics by numerically solving the time-dependent Schrödinger equation for the compound system (the electronic spin plus the bath spins). Our results demonstrate that the effect of the spin bath cannot always be modeled as a randomly varying magnetic field acting on the electronic spin. We consider two dynamical regimes: the spin relaxation in a constant magnetic field, and the spin tunneling in the linearly varying magnetic field passing the avoided level crossing, so-called Landau-Zener-Stückelberg (LZS) transition. For the first regime, we confirmed that the hole in the magnetization distribution has the width of the hyperfine fields distribution. For the second regime, we found that the transition probability for moderately slow sweeps deviates from the standard LZS prediction, while for the fast sweeps the deviation is negligible.

  19. Quantum tunneling of magnetization in molecular nanomagnet Fe8 studied by NMR

    International Nuclear Information System (INIS)

    Maegawa, Satoru; Ueda, Miki

    2003-01-01

    Magnetization and NMR measurements have been performed for single crystals of molecular magnet Fe8. The field and temperature dependences of magnetization below 25 K are well described in terms of the isolated clusters with the total spin S=10. The stepwise recoveries of 1 H-NMR signals at the level crossing fields caused by the resonant quantum tunneling of magnetization were observed below 400 mK. The recovery of the NMR signals are explained by the fluctuation caused by the transition between the energy states of Fe magnetizations governed by Landau-Zener quantum transitions

  20. Isotopic effect on the quantum tunneling of the magnetization of molecular nanomagnets

    International Nuclear Information System (INIS)

    Sessoli, Roberta; Caneschi, Andrea; Gatteschi, Dante; Sorace, Lorenzo; Cornia, Andrea; Wernsdorfer, Wolfgang

    2001-01-01

    The molecular cluster [Fe 8 (tacn) 6 O 2 (OH) 12 ]Br 8 ·9H 2 O, Fe 8 , characterized by S=10, with biaxial magnetic anisotropy is an ideal system to investigate quantum effects in the dynamics of the magnetization. Resonant quantum tunneling gives rise to stepped hysteresis cycles and below 0.35 K pure quantum tunneling of the magnetization has been observed. The role of hyperfine fields in promoting the tunneling as a source of dynamic broadening of the states involved in the tunnel transition is investigated by preparing and characterizing two isotopically enriched samples using 57 Fe and 2 H. The relaxation rate in the tunneling regime is proportional to the hyperfine field generated by the nuclei. Also, the intrinsic linewidth of the tunneling resonance scales with the hyperfine field as confirmed by calculations of the super (or transfer) and direct hyperfine interactions. Preliminary results on a novel cluster of formula [Fe 4 (OCH 3 ) 6 (dpm) 6 ], Fe 4 , suited for a more dramatic isotope effect on the tunneling rate are also reported

  1. Isotopic effect on the quantum tunneling of the magnetization of molecular nanomagnets

    Energy Technology Data Exchange (ETDEWEB)

    Sessoli, Roberta E-mail: sessoli@chim1.unifi.it; Caneschi, Andrea; Gatteschi, Dante; Sorace, Lorenzo; Cornia, Andrea; Wernsdorfer, Wolfgang

    2001-05-01

    The molecular cluster [Fe{sub 8}(tacn){sub 6}O{sub 2}(OH){sub 12}]Br{sub 8}{center_dot}9H{sub 2}O, Fe{sub 8}, characterized by S=10, with biaxial magnetic anisotropy is an ideal system to investigate quantum effects in the dynamics of the magnetization. Resonant quantum tunneling gives rise to stepped hysteresis cycles and below 0.35 K pure quantum tunneling of the magnetization has been observed. The role of hyperfine fields in promoting the tunneling as a source of dynamic broadening of the states involved in the tunnel transition is investigated by preparing and characterizing two isotopically enriched samples using {sup 57}Fe and {sup 2}H. The relaxation rate in the tunneling regime is proportional to the hyperfine field generated by the nuclei. Also, the intrinsic linewidth of the tunneling resonance scales with the hyperfine field as confirmed by calculations of the super (or transfer) and direct hyperfine interactions. Preliminary results on a novel cluster of formula [Fe{sub 4}(OCH{sub 3}){sub 6}(dpm){sub 6}], Fe{sub 4}, suited for a more dramatic isotope effect on the tunneling rate are also reported.

  2. Spin-torque oscillation in large size nano-magnet with perpendicular magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Linqiang, E-mail: LL6UK@virginia.edu [Department of Physics, University of Virginia, Charlottesville, VA 22904 (United States); Kabir, Mehdi [Department of Electrical & Computer Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Dao, Nam; Kittiwatanakul, Salinporn [Department of Materials Science & Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Cyberey, Michael [Department of Electrical Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Wolf, Stuart A. [Department of Physics, University of Virginia, Charlottesville, VA 22904 (United States); Department of Materials Science & Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Institute of Defense Analyses, Alexandria, VA 22311 (United States); Stan, Mircea [Department of Electrical & Computer Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Lu, Jiwei [Department of Materials Science & Engineering, University of Virginia, Charlottesville, VA 22904 (United States)

    2017-06-15

    Highlights: • 500 nm size nano-pillar device was fabricated by photolithography techniques. • A magnetic hybrid structure was achieved with perpendicular magnetic fields. • Spin torque switching and oscillation was demonstrated in the large sized device. • Micromagnetic simulations accurately reproduced the experimental results. • Simulations demonstrated the synchronization of magnetic inhomogeneities. - Abstract: DC current induced magnetization reversal and magnetization oscillation was observed in 500 nm large size Co{sub 90}Fe{sub 10}/Cu/Ni{sub 80}Fe{sub 20} pillars. A perpendicular external field enhanced the coercive field separation between the reference layer (Co{sub 90}Fe{sub 10}) and free layer (Ni{sub 80}Fe{sub 20}) in the pseudo spin valve, allowing a large window of external magnetic field for exploring the free-layer reversal. A magnetic hybrid structure was achieved for the study of spin torque oscillation by applying a perpendicular field >3 kOe. The magnetization precession was manifested in terms of the multiple peaks on the differential resistance curves. Depending on the bias current and applied field, the regions of magnetic switching and magnetization precession on a dynamical stability diagram has been discussed in details. Micromagnetic simulations are shown to be in good agreement with experimental results and provide insight for synchronization of inhomogeneities in large sized device. The ability to manipulate spin-dynamics on large size devices could be proved useful for increasing the output power of the spin-transfer nano-oscillators (STNOs).

  3. A facile approach for screening isolated nanomagnetic behavior for bit-patterned media

    International Nuclear Information System (INIS)

    Thiyagarajah, Naganivetha; Ng, Vivian; Asbahi, Mohamed; Yakovlev, Nikolai L; Yang, Joel K W; Wong, Rick T J; Low, Kendrick W M

    2014-01-01

    Bit-patterned media (BPM) fabricated by the direct deposition of magnetic material onto prepatterned arrays of nanopillars is a promising approach for increasing magnetic recording of areal density. One of the key challenges of this approach is to identify and control the magnetic interaction between the bits (on top of the nanopillars) and the trench material between the pillars. Using independent techniques, including magnetic force microscopy, the variable-angle magneto-optic Kerr effect, and remanence curves, we were able to determine the presence and relative intensities of exchange and dipolar interactions in Co-Pd multilayer-based BPM fabricated by direct deposition. We found that for pitches of 30 nm or less, there were negligible exchange interactions, and the bits were found to be magnetically isolated. As we move to higher densities, the absence of exchange interactions indicates that direct deposition is a promising approach to BPM fabrication. (papers)

  4. Accuracy of Visante and Zeiss-Humphrey Optical Coherence Tomographers and their cross calibration with optical pachymetry and physical references

    Directory of Open Access Journals (Sweden)

    Jyotsna Maram

    2011-10-01

    Conclusions: Using references lenses with refractive index of the cornea (1.376 allows rapid and simple calibration and cross calibration of instruments for measuring the corneal thickness. The Visante and OCT II do not produce measurements that are equal to physical references with refractive index equal to the human cornea.

  5. Photographic Observations of Major Planets and Their Moons During 1961-1990 at the MAO NAS of Ukraine

    Science.gov (United States)

    Yizhakevych, O. M.; Andruk, V. M.; Pakuliak, L. K.

    We present the results of photographic observations' processing of Saturn's moons, Uranus, Neptune and their moons on the basis of MAO NAS of Ukraine photographic observational archive. The analysis of the results is given. Observations were obtained using 4 telescopes: Double Long-Focus Astrograph (DLFA, D/F = 400/5500), Zeiss Double Astrograph (DAZ, D/F= 400/3000), Reflector Zeiss-600 (D/F= 600/7500), Wideangle Astrograph, (DWA, D/F= 400/2000). Observations were carried out during 1961 - 1990 (http://gua.db.ukrvo. org). Digitizing of plates has been done by EPSON EXPRESSION 10000XL (EE) flatbed scanner in 16-bit gray color range with resolution 1200dpi.(Andruk et al.: 2005, 2012; Golovnja et al.: 2010;. Protsyuk et al. 2014a, 2014b). The reduction of plates was made using the software developed in MAO NASU in the enhanced LINUX-MIDAS software kit. (Andruk V. et al.: 2016a, 2016b). Tycho2 was used as a reference system. The internal accuracy of the reduction for the first three instruments is ±0.08 - ±0.13 arcsec for both coordinates. For the wide angle astrograph DWA, RMS errors appeared 2 - 2.5 times higher. The total amount of processed plates with images of Saturn's moons is 209 (511 frames), 33 plates contain the images of Uranus and U1,U2,U3,U4 moons, 29 plates have images of Neptune and N1 moon (Yizhakevych et al., 2015, 2016, 2017; Protsyuk et al., 2015). The online comparison of calculated positions of objects with IMCCE ephemeris data was made (http://lnfm1.sai.msu.ru/neb/nss/nssephmf.htm).

  6. Using Donor Lenticules Obtained Through SMILE for an Epikeratophakia Technique Combined With Phototherapeutic Keratectomy.

    Science.gov (United States)

    Zhao, Jing; Sun, Ling; Shen, Yang; Tian, Mi; Yao, Peijun; Zhou, Xingtao

    2016-12-01

    To investigate the feasibility, safety, and efficacy of using a donor lenticule created during small incision lenticule extraction (SMILE) in an epikeratophakia technique combined with phototherapeutic keratectomy (PTK). Six patients with decreased visual acuity due to a recurrence of corneal dystrophy were included in this prospective pilot study. PTK was performed using the MEL 80 excimer laser (Carl Zeiss Meditec, Jena, Germany) followed by the transplantation of donor lenticules onto the recipient eyes. These lenticules were extracted during SMILE procedures using the VisuMax femtosecond laser (Carl Zeiss Meditec) on 6 donors with myopia and served as the epikeratophakia tissue. The surgeries and postoperative follow-up examinations were uneventful and no complications were noted over 6 months of follow-up. The epithelium remodelling was achieved within 1 month. At the last measurement, the corrected distance visual acuity of all recipient eyes gained at least two lines. Five eyes (83.3%) gained at least two lines of uncorrected distance visual acuity compared to their preoperative levels. Mean keratometric power increased by 5.97 ± 3.73 diopters and central corneal thickness increased by 55.25 ± 36.38 µm. The epithelium healed and the lenticules remained clear over the follow-up period as observed under slit-lamp examination. Anterior segment optical coherence tomography observation showed the lenticule was transparent with a visible demarcation line during the follow-up examination. The use of a SMILE lenticule as a donor lenticule for an epikeratophakia technique appears feasible and safe in the short term. The predictability and long-term effects need further investigation. [J Refract Surg. 2016;32(12):840-845.]. Copyright 2016, SLACK Incorporated.

  7. Professor Ernst Bresslau, founder of the Zoology Departments at the Universities of Cologne and Sao Paulo: lessons to learn from his life history.

    Science.gov (United States)

    Pflüger, Hans-Joachim

    2017-06-01

    In this article, the life history of the founding father of the departments of Zoology at the Universities of Cologne and Sao Paulo, Prof. Ernst Bresslau, is described on occasion of the establishing of the "Ernst Bresslau Guest Professorship" at the University of Cologne. His main scientific achievements are discussed, in particular his research on the evolutionary origin of the mammary apparatus, in addition to his broad interest in biological topics. Among the many technical advancements that he introduced was the micro slow-motion camera developed together with the Zeiss Company which allowed to film ciliary beats at high speeds. Copyright © 2017 Elsevier GmbH. All rights reserved.

  8. Use of X-ray fluorescence analysis in studying vertical element migration in weathering zone

    International Nuclear Information System (INIS)

    Houdkova, Z.; Hally, J.

    1980-01-01

    The vertical migration of elements was studied in a model area of the Zelivka river basin. The VRS 2 Zeiss GDR analyzer, connected to automatic processor KSR 4 100, were used for the study of concentration variations. Soil samples were taken from bore holes drilled to a depth of the solid bedrock (0 to 6 m). The contents of SiO 2 , Al 2 O 3 , Fe 2 O 3 , K 2 O, CaO, TiO 2 , P 2 O 5 and MnO were determined in concentration ranges from 10 -2 to 10 1 %. The method was tested in comparative measurements against conventional methods of chemical analysis. (author)

  9. Application of stereo photogrammetric techniques for measuring African Elephants

    Directory of Open Access Journals (Sweden)

    A. J Hall-Martin

    1979-12-01

    Full Text Available Measurements of shoulder height and back length of African elephants were obtained by means of stereo photogrammetric techniques. A pair of Zeiss UMK 10/1318 cameras, mounted on a steel frame on the back of a vehicle, were used to photograph the elephants in the Addo Elephant National Park, Republic of South Africa. Several modifications of normal photogrammetry procedure applicable to the field situation (eg. control points and the computation of results (eg. relative orientation are briefly mentioned. Six elephants were immobilised after being photographed and the measurements obtained from them agreed within a range of 1 cm-10 cm with the photogrammetric measurements.

  10. Gross anatomy of central nervous system in firefly, Pteroptyx tener (Coleoptera: Lampyridae)

    Science.gov (United States)

    Hudawiyah, Nur; Wahida, O. Nurul; Norela, S.

    2015-09-01

    This paper describes for the first time the organization and fine structure of the central nervous system (CNS) in the fireflies, Pteroptyx tener (Coleoptera: Lampyridae). The morphology of the CNS was examined by using Carl Zeiss AxioScope A1 photomicroscope with iSolution Lite software. Some specific structural features such as the localization of protocerebrum, deutocerebrum and tritocerebrum in the brain region were analyzed. Other than that, the nerve cord and its peripheral structure were also analyzed. This study suggests that, there is a very obvious difference between male and female central nervous system which illustrates that they may differ in function in controlling physiological and behavioral activities.

  11. Towards developing a compact model for magnetization switching in straintronics magnetic random access memory devices

    International Nuclear Information System (INIS)

    Barangi, Mahmood; Erementchouk, Mikhail; Mazumder, Pinaki

    2016-01-01

    Strain-mediated magnetization switching in a magnetic tunneling junction (MTJ) by exploiting a combination of piezoelectricity and magnetostriction has been proposed as an energy efficient alternative to spin transfer torque (STT) and field induced magnetization switching methods in MTJ-based magnetic random access memories (MRAM). Theoretical studies have shown the inherent advantages of strain-assisted switching, and the dynamic response of the magnetization has been modeled using the Landau-Lifshitz-Gilbert (LLG) equation. However, an attempt to use LLG for simulating dynamics of individual elements in large-scale simulations of multi-megabyte straintronics MRAM leads to extremely time-consuming calculations. Hence, a compact analytical solution, predicting the flipping delay of the magnetization vector in the nanomagnet under stress, combined with a liberal approximation of the LLG dynamics in the straintronics MTJ, can lead to a simplified model of the device suited for fast large-scale simulations of multi-megabyte straintronics MRAMs. In this work, a tensor-based approach is developed to study the dynamic behavior of the stressed nanomagnet. First, using the developed method, the effect of stress on the switching behavior of the magnetization is investigated to realize the margins between the underdamped and overdamped regimes. The latter helps the designer realize the oscillatory behavior of the magnetization when settling along the minor axis, and the dependency of oscillations on the stress level and the damping factor. Next, a theoretical model to predict the flipping delay of the magnetization vector is developed and tested against LLG-based numerical simulations to confirm the accuracy of findings. Lastly, the obtained delay is incorporated into the approximate solutions of the LLG dynamics, in order to create a compact model to liberally and quickly simulate the magnetization dynamics of the MTJ under stress. Using the developed delay equation, the

  12. Towards developing a compact model for magnetization switching in straintronics magnetic random access memory devices

    Energy Technology Data Exchange (ETDEWEB)

    Barangi, Mahmood, E-mail: barangi@umich.edu; Erementchouk, Mikhail; Mazumder, Pinaki [Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109-2121 (United States)

    2016-08-21

    Strain-mediated magnetization switching in a magnetic tunneling junction (MTJ) by exploiting a combination of piezoelectricity and magnetostriction has been proposed as an energy efficient alternative to spin transfer torque (STT) and field induced magnetization switching methods in MTJ-based magnetic random access memories (MRAM). Theoretical studies have shown the inherent advantages of strain-assisted switching, and the dynamic response of the magnetization has been modeled using the Landau-Lifshitz-Gilbert (LLG) equation. However, an attempt to use LLG for simulating dynamics of individual elements in large-scale simulations of multi-megabyte straintronics MRAM leads to extremely time-consuming calculations. Hence, a compact analytical solution, predicting the flipping delay of the magnetization vector in the nanomagnet under stress, combined with a liberal approximation of the LLG dynamics in the straintronics MTJ, can lead to a simplified model of the device suited for fast large-scale simulations of multi-megabyte straintronics MRAMs. In this work, a tensor-based approach is developed to study the dynamic behavior of the stressed nanomagnet. First, using the developed method, the effect of stress on the switching behavior of the magnetization is investigated to realize the margins between the underdamped and overdamped regimes. The latter helps the designer realize the oscillatory behavior of the magnetization when settling along the minor axis, and the dependency of oscillations on the stress level and the damping factor. Next, a theoretical model to predict the flipping delay of the magnetization vector is developed and tested against LLG-based numerical simulations to confirm the accuracy of findings. Lastly, the obtained delay is incorporated into the approximate solutions of the LLG dynamics, in order to create a compact model to liberally and quickly simulate the magnetization dynamics of the MTJ under stress. Using the developed delay equation, the

  13. Relaxation of the magnetization in magnetic molecules

    Science.gov (United States)

    Carretta, S.; Bianchi, A.; Liviotti, E.; Santini, P.; Amoretti, G.

    2006-04-01

    Several mechanisms characterize the relaxation dynamics in magnetic molecules. We investigate two of them, spin-lattice coupling and incoherent quantum tunneling. The effect of the phonon heat bath is studied by analyzing the exponential time decay of the autocorrelation of the magnetization. We show that in ferromagnetic (Cu6) and antiferromagnetic (Fe6) molecular rings this decay is characterized by a single characteristic time. At very low temperature, relaxation through incoherent quantum tunneling may occur in nanomagnets such as Fe8 or Ni4. The mixing between levels with different values of the total spin (S mixing) greatly influences this mechanism. In particular, we demonstrate that a fourth-order anisotropy term O44, required to interpret experimental electron paramagnetic resonance and relaxation data in Ni4, naturally arises when S mixing is considered in calculations.

  14. Nanoscience The Science of the Small in Physics, Engineering, Chemistry, Biology and Medicine

    CERN Document Server

    Schaefer, Hans-Eckhardt

    2010-01-01

    Nanoscience stands out for its interdisciplinarity. Barriers between disciplines disappear and the fields tend to converge at the very smallest scale, where basic principles and tools are universal. Novel properties are inherent to nanosized systems due to quantum effects and a reduction in dimensionality: nanoscience is likely to continue to revolutionize many areas of human activity, such as materials science, nanoelectronics, information processing, biotechnology and medicine. This textbook spans all fields of nanoscience, covering its basics and broad applications. After an introduction to the physical and chemical principles of nanoscience, coverage moves on to the adjacent fields of microscopy, nanoanalysis, synthesis, nanocrystals, nanowires, nanolayers, carbon nanostructures, bulk nanomaterials, nanomechanics, nanophotonics, nanofluidics, nanomagnetism, nanotechnology for computers, nanochemistry, nanobiology, and nanomedicine. Consequently, this broad yet unified coverage addresses research in academ...

  15. Short-Range Correlated Magnetic Core-Shell CrO₂/Cr₂O₃ Nanorods: Experimental Observations and Theoretical Considerations.

    Science.gov (United States)

    Gandhi, Ashish C; Li, Tai-Yue; Chan, Ting Shan; Wu, Sheng Yun

    2018-05-09

    With the evolution of synthesis and the critical characterization of core-shell nanostructures, short-range magnetic correlation is of prime interest in employing their properties to develop novel devices and widespread applications. In this regard, a novel approach of the magnetic core-shell saturated magnetization (CSSM) cylinder model solely based on the contribution of saturated magnetization in one-dimensional CrO₂/Cr₂O₃ core-shell nanorods (NRs) has been developed and applied for the determination of core-diameter and shell-thickness. The nanosized effect leads to a short-range magnetic correlation of ferromagnetic core-CrO₂ extracted from CSSM, which can be explained using finite size scaling method. The outcome of this study is important in terms of utilizing magnetic properties for the critical characterization of core-shell nanomagnetic materials.

  16. Carbon coated Fe, Co and Ni Nanoparticles produced by high pressure CVD and their potential for medical applications

    Energy Technology Data Exchange (ETDEWEB)

    El-Gendy, A.A.; Ibrahim, E.M.M.; Khavrus, V.; Krupskaya, Y.; Leonhardt, A.; Klingeler, R.; Buechner, B. [Leibniz Institute for Solid State and Materials Research (IFW), Dresden (Germany)

    2009-07-01

    Fe rate at C, Co rate at C and Ni rate at C nanocapsules have been produced by high pressure chemical vapour deposition (HPCVD). Scanning electron microscopy images prove that most of the particles are coated with carbon. High resolution transmission electron microscopy imaging confirms that these particles have a broad size distribution and a core/shell structure. In addition, individual nanoparticles are found inside a carbon capsule as well as several particles together in one shell. X-ray diffraction confirms the phases and allows calculating the average particle size from the width of the peaks. Our magnetisation studies confirm that the coated particles are ferromagnetic up to 400 K. AC magnetic heating studies have been performed which imply the potential of carbon coated nanomagnets for applications in hyperthermia therapies.

  17. Use of magnetic resonance to study biodistribution of dextran-coated magnetic fluid intravenously administered in mice

    International Nuclear Information System (INIS)

    Lacava, L.M.; Lacava, Z.G.M.; Azevedo, R.B.; Chaves, S.B.; Garcia, V.A.P.; Silva, O.; Pelegrini, F.; Buske, N.; Gansau, C.; Da Silva, M.F.; Morais, P.C.

    2002-01-01

    Magnetic resonance was used to investigate the kinetic disposition and the subsequent biodistribution of dextran-coated magnetite nanoparticles (9.4 nm core diameter) after intravenous injection of a bolus dose in female Swiss mice. The X-band spectra show a broad single-line at g∼2, typical of nanomagnetic particles suspended in a non-magnetic matrix. In the first 90 min the time-decay of the nanoparticle concentration in the bloodstream follows the one-exponential (one-compartment) model with a half-life of 6.9 min. With respect to blood the clearance (90 μl/min) and the volume of distribution (900 μl) were obtained from the magnetic resonance data. Magnetite nanoparticles were found 90 min after administration in liver and spleen with a typical absorption half-life of 14 min

  18. 2nd international conference on advanced nanomaterials and nanotechnology

    CERN Document Server

    Goswami, D; Perumal, A

    2013-01-01

    Nanoscale science and technology have occupied centre stage globally in modern scientific research and discourses in the early twenty first century. The enabling nature of the technology makes it important in modern electronics, computing, materials, healthcare, energy and the environment. This volume contains selected articles presented (as Invited/Oral/Poster presentations) at the 2nd international conference on advanced materials and nanotechnology (ICANN-2011) held recently at the Indian Institute of Technology Guwahati, during Dec 8-10, 2011. The list of topics covered in this proceedings include: Synthesis and self assembly of nanomaterials Nanoscale characterisation Nanophotonics & Nanoelectronics Nanobiotechnology Nanocomposites  F   Nanomagnetism Nanomaterials for Enery Computational Nanotechnology Commercialization of Nanotechnology The conference was represented by around 400 participants from several countries including delegates invited from USA, Germany, Japan, UK, Taiwan, Italy, Singapor...

  19. Magnetic system for small-angle neutron scattering investigation at YUMO instrument of nanomaterials

    International Nuclear Information System (INIS)

    Balasoiu, M.; Kirilov, A.S.; Kutuzov, S.A.; Smirnov, A.A.; Kuklin, A.I.; Kappel, W.; Cios, M.; Cios, A.

    2009-01-01

    SANS measurements using unpolarized neutron beams are able to provide quantitative information on the magnetic microstructure and the magnitude and microstructure of the magnetic anisotropy of nanomagnetic materials. Here we describe a new magnetic system for SANS at YUMO spectrometer. The system includes 2.5 T electromagnet established on a two-axes goniometric table, power supply, cooling system, PC-based control equipment. Main features of magnetic system are: big changeable gap for the samples (up to 130 mm size), computer controlled horizontal and vertical rotation and sufficiently large space for the sample holders. The system has been developed in cooperation with the INCDIE ICPE-CA (Bucharest) and CIPEC SRL (Bucharest). First experimental results of SANS in ferrofluids and magnetic elastomers obtained at YUMO spectrometer equipped with the new magnetic system are presented

  20. Phase-dependent deterministic switching of magnetoelectric spin wave detector in the presence of thermal noise via compensation of demagnetization

    Energy Technology Data Exchange (ETDEWEB)

    Dutta, Sourav, E-mail: sdutta38@gatech.edu; Naeemi, Azad [School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Nikonov, Dmitri E.; Manipatruni, Sasikanth; Young, Ian A. [Components Research, Intel Corporation, Hillsboro, Oregon 97124 (United States)

    2015-11-09

    The possibility of achieving phase-dependent deterministic switching of the magnetoelectric spin wave detector in the presence of thermal noise has been discussed. The proposed idea relies on the modification of the energy landscape by partially canceling the out-of-plane demagnetizing field and the resultant change in the intrinsic magnetization dynamics to drive the nanomagnet towards a preferential final magnetization state. The remarkable increase in the probability of successful switching can be accounted for by the shift in the location of the saddle point in the energy landscape and a resultant change in the nature of the relaxation dynamics of the magnetization from a highly precessional to a fairly damped one and an increased dependence on the initial magnetization values, a crucial requirement for phase-dependent spin wave detection.

  1. Optical coherence tomography for glaucoma diagnosis: An evidence based meta-analysis

    Science.gov (United States)

    Armstrong, James J.; Pintwala, Robert; Hutnik, Cindy

    2018-01-01

    Purpose Early detection, monitoring and understanding of changes in the retina are central to the diagnosis of glaucomatous optic neuropathy, and vital to reduce visual loss from this progressive condition. The main objective of this investigation was to compare glaucoma diagnostic accuracy of commercially available optical coherence tomography (OCT) devices (Zeiss Stratus, Zeiss Cirrus, Heidelberg Spectralis and Optovue RTVue, and Topcon 3D-OCT). Patients 16,104 glaucomatous and 11,543 normal eyes reported in 150 studies. Methods Between Jan. 2017 and Feb 2017, MEDLINE®, EMBASE®, CINAHL®, Cochrane Library®, Web of Science®, and BIOSIS® were searched for studies assessing glaucoma diagnostic accuracy of the aforementioned OCT devices. Meta-analysis was performed pooling area under the receiver operating characteristic curve (AUROC) estimates for all devices, stratified by OCT type (RNFL, macula), and area imaged. Results 150 studies with 16,104 glaucomatous and 11,543 normal control eyes were included. Key findings: AUROC of glaucoma diagnosis for RNFL average for all glaucoma patients was 0.897 (0.887–0.906, n = 16,782 patient eyes), for macula ganglion cell complex (GCC) was 0.885 (0.869–0.901, n = 4841 eyes), for macula ganglion cell inner plexiform layer (GCIPL) was 0.858 (0.835–0.880, n = 4211 eyes), and for total macular thickness was 0.795 (0.754–0.834, n = 1063 eyes). Conclusion The classification capability was similar across all 5 OCT devices. More diagnostically favorable AUROCs were demonstrated in patients with increased glaucoma severity. Diagnostic accuracy of RNFL and segmented macular regions (GCIPL, GCC) scans were similar and higher than total macular thickness. This study provides a synthesis of contemporary evidence with features of robust inclusion criteria and large sample size. These findings may provide guidance to clinicians when navigating this rapidly evolving diagnostic area characterized by numerous options. PMID:29300765

  2. Utilizing Neon Ion Microscope for GaSb nanopatterning studies: Nanostructure formation and comparison with low energy nanopatterning

    International Nuclear Information System (INIS)

    El-Atwani, Osman; Huynh, Chuong; Norris, Scott

    2016-01-01

    Graphical abstract: - Highlights: • Carl Zeiss-neon ion microscope was used to irradiated GaSb surfaces with 5 keV neon. • In-situ imaging using helium beam and ex-situ imaging using an electron beam were performed. • Differences in imaging output between the helium and the electron beam were observed. • Transition occurred in the nanostructure type and formation mechanism as the energy is changed from 2 to 5 keV. • Collision cascade simulations suggested a transition toward bulk-driven mechanisms. - Abstract: Low energy irradiation of GaSb surfaces has been shown to lead to nanopillar formation. Being performed ex-situ, controlling the parameters of the ion beam for controlled nanopattern formation is challenging. While mainly utilized for imaging and cutting purposes, the development of multibeam (helium/neon) ion microscopes has opened the path towards the use of these microscopes for in-situ ion irradiation and nanopatterning studies. In this study, in-situ irradiation (neon ions)/imaging (helium ions) of GaSb surfaces is performed using Carl Zeiss-neon ion microscope at low energies (5 and 10 keV). Imaging with helium ions, nanodots were shown to form at particular fluences after which are smoothed. Ex-situ imaging with SEM showed nanopore formation of size controlled by the ion energy and fluence. Compared to lower energy ex-situ neon ion irradiation at similar fluxes, where nanopillars are formed, the results demonstrated a transition in the nanostructure type and formation mechanism as the energy is changed from 2 to 5 keV. Simulations show an increase in the ballistic diffusion and a decrease in the strength of phase separation as a function of ion energy in agreement with the suppression of nanopillar formation at higher energies. Collision cascade simulations suggest a transition toward bulk-driven mechanisms.

  3. VARIABILITY IN FOVEAL AVASCULAR ZONE AND CAPILLARY DENSITY USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY MACHINES IN HEALTHY EYES.

    Science.gov (United States)

    Magrath, George N; Say, Emil Anthony T; Sioufi, Kareem; Ferenczy, Sandor; Samara, Wasim A; Shields, Carol L

    2017-11-01

    To evaluate the variability in foveal avascular zone (FAZ) and capillary density measurements on optical coherence tomography angiography using Optovue RTVue XR Avanti (OA) (Optovue) and Zeiss Cirrus HD-OCT 5000 (ZC) (Carl Zeiss Meditec). In this prospective, comparative case series, parafoveal (3 × 3 mm) optical coherence tomography angiography scans were obtained on healthy volunteers using both the Avanti and Cirrus. The FAZ area and capillary density at the level of both the superficial and deep capillary plexus were measured automatically using the built-in ReVue software (Optovue) with the Avanti as well as manually using ImageJ (National Institutes of Health) with both machines. There were 50 eyes in 25 healthy volunteers included in the analysis. Mean subject age was 33 years and there were 14 women (56%). On optical coherence tomography, mean central macular thickness was significantly greater on OA (259.1 μm) than ZC (257.6 μm, P = 0.0228). On optical coherence tomography angiography, mean superficial and deep plexus FAZ measured 0.2855 mm and 0.3465 mm on Avanti automated (A-A), 0.2739 mm and 0.3637 mm on Avanti manual (A-M), and 0.2657 mm and 0.3993 mm on Cirrus manual (C-M), respectively. There were no statistically significant differences in superficial plexus FAZ measurements between the A-A and A-M (P = 0.4019) or A-A and C-M (P = 0.1336). The A-M measured significantly larger than C-M (P = 0.0396). Deep plexus FAZ measurements were similar on A-A and A-M (P = 0.6299), but both were significantly less compared with C-M (P machine and technique are consistent and reliable between fellow eyes, significant variability exists in FAZ and capillary density measurements among different machines and techniques. Comparison of measurements across machines and techniques should be considered with caution.

  4. Theaters of time and space: The American planetarium community, 1930-1970

    Science.gov (United States)

    Marche, Jordan Dale, II

    American astronomy education was transformed by the introduction of a remarkable teaching tool---the projection planetarium. Conceived at the Carl Zeiss firm of Jena, Germany, the first prototype was exhibited at the Deutsches Museum, Munich, in 1923. Between 1930 and 1970, more than 700 planetaria were completed or remained under construction in the Unite States, Canada, and Mexico. Members of the American planetarium community united to form the first continent-wide professional association and to launch its quarterly journal, signifying that disciplinary maturity had been achieved. Social developments in the American planetarium community are examined in light of three principal issues (along with the role of gender): patronage, professionalization, and popularization. The analytical narrative is supplemented by quantitative analysis of North American planetaria and their personnel. Utilizing methods employed in collective biography, the Appendix contains further assessments derived from five professional traits of the community's 919 known planetarium directors. On the basis of technological developments and the changing nature of patronage, three distinct periods of historical development are recognized. In the formative stage (1930--1946), the community was dominated by Zeiss-equipped facilities installed at five metropolitan cities. During the second period (1947--1957), inexpensive pinhole-style projectors, marketed by Philadelphia entrepreneur Armand N. Spitz, revolutionized the availability of 'artificial skies'. In response to the "crisis of confidence" triggered by Sputnik's launch, a third developmental period (1958--1970) ensued. The necessity of offering a space science education to rapidly growing numbers of young people justified the construction of hundreds of new planetaria through the 1960s. Originally created for teaching the confirmation of scientific theories, planetaria became important tools for researching other biological and educational

  5. [Comparison of film-screen combinations with contrast detail diagram and interactive image analysis. 2: Linear assessment of grey scale ranges with interactive image analysis].

    Science.gov (United States)

    Stamm, G; Eichbaum, G; Hagemann, G

    1997-09-01

    The following three screen-film combinations were compared: a) a combination of anticrossover film and UV-light emitting screens, b) a combination of blue-light emitting screens and film, and c) a conventional green fluorescing screen-film combination. Radiographs of a specially designed plexiglass phantom (0.2 x 0.2 x 0.12 m3) with bar patterns of lead and plaster and of air, respectively were obtained using the following parameters: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminum pre-filter, a grid with 40 lines/cm (12:1) and a focus-detector distance of 1.15 m. Image analysis was performed using an IBAS system and a Zeiss Kontron computer. Display conditions were the following: display distance 0.12 m, a vario film objective 35/70 (Zeiss), a video camera tube with a PbO photocathode, 625 lines (Siemens Heimann), an IBAS image matrix of 512 x 512 pixels with a resolution of 7 lines/mm, the projected matrix area was 5000 microns2. Grey scale ranges were measured on a line perpendicular to the grouped bar patterns. The difference between the maximum and minimum density value served as signal. The spatial resolution of the detector system was measured when the signal value was three times higher than the standard deviation of the means of multiple density measurements. The results showed considerable advantages of the two new screen-film combinations as compared to the conventional screen-film combination. The result was contradictory to the findings with pure visual assessment of thresholds (part I) that had found no differences. The authors concluded that (automatic) interactive image analysis algorithms serve as an objective measure and are specifically advantageous when small differences in image quality are to be evaluated.

  6. Utilizing Neon Ion Microscope for GaSb nanopatterning studies: Nanostructure formation and comparison with low energy nanopatterning

    Energy Technology Data Exchange (ETDEWEB)

    El-Atwani, Osman, E-mail: oelatwan25@gmail.com [School of Nuclear Engineering, Purdue University, West Lafayette, Indiana 47907 (United States); Huynh, Chuong [Carl Zeiss Microscopy, LLC, One Corporation Way, Peabody, MA 01960 (United States); Norris, Scott [Department of Mathematics, Southern Methodist University, Dallas, TX 75275 (United States)

    2016-05-01

    Graphical abstract: - Highlights: • Carl Zeiss-neon ion microscope was used to irradiated GaSb surfaces with 5 keV neon. • In-situ imaging using helium beam and ex-situ imaging using an electron beam were performed. • Differences in imaging output between the helium and the electron beam were observed. • Transition occurred in the nanostructure type and formation mechanism as the energy is changed from 2 to 5 keV. • Collision cascade simulations suggested a transition toward bulk-driven mechanisms. - Abstract: Low energy irradiation of GaSb surfaces has been shown to lead to nanopillar formation. Being performed ex-situ, controlling the parameters of the ion beam for controlled nanopattern formation is challenging. While mainly utilized for imaging and cutting purposes, the development of multibeam (helium/neon) ion microscopes has opened the path towards the use of these microscopes for in-situ ion irradiation and nanopatterning studies. In this study, in-situ irradiation (neon ions)/imaging (helium ions) of GaSb surfaces is performed using Carl Zeiss-neon ion microscope at low energies (5 and 10 keV). Imaging with helium ions, nanodots were shown to form at particular fluences after which are smoothed. Ex-situ imaging with SEM showed nanopore formation of size controlled by the ion energy and fluence. Compared to lower energy ex-situ neon ion irradiation at similar fluxes, where nanopillars are formed, the results demonstrated a transition in the nanostructure type and formation mechanism as the energy is changed from 2 to 5 keV. Simulations show an increase in the ballistic diffusion and a decrease in the strength of phase separation as a function of ion energy in agreement with the suppression of nanopillar formation at higher energies. Collision cascade simulations suggest a transition toward bulk-driven mechanisms.

  7. Validation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening.

    Science.gov (United States)

    Rajalakshmi, Ramachandran; Arulmalar, Subramanian; Usha, Manoharan; Prathiba, Vijayaraghavan; Kareemuddin, Khaji Syed; Anjana, Ranjit Mohan; Mohan, Viswanathan

    2015-01-01

    To evaluate the sensitivity and specificity of "fundus on phone' (FOP) camera, a smartphone based retinal imaging system, as a screening tool for diabetic retinopathy (DR) detection and DR severity in comparison with 7-standard field digital retinal photography. Single-site, prospective, comparative, instrument validation study. 301 patients (602 eyes) with type 2 diabetes underwent standard seven-field digital fundus photography with both Carl Zeiss fundus camera and indigenous FOP at a tertiary care diabetes centre in South India. Grading of DR was performed by two independent retina specialists using modified Early Treatment of Diabetic Retinopathy Study grading system. Sight threatening DR (STDR) was defined by the presence of proliferative DR(PDR) or diabetic macular edema. The sensitivity, specificity and image quality were assessed. The mean age of the participants was 53.5 ±9.6 years and mean duration of diabetes 12.5±7.3 years. The Zeiss camera showed that 43.9% had non-proliferative DR(NPDR) and 15.3% had PDR while the FOP camera showed that 40.2% had NPDR and 15.3% had PDR. The sensitivity and specificity for detecting any DR by FOP was 92.7% (95%CI 87.8-96.1) and 98.4% (95%CI 94.3-99.8) respectively and the kappa (ĸ) agreement was 0.90 (95%CI-0.85-0.95 p<0.001) while for STDR, the sensitivity was 87.9% (95%CI 83.2-92.9), specificity 94.9% (95%CI 89.7-98.2) and ĸ agreement was 0.80 (95%CI 0.71-0.89 p<0.001), compared to conventional photography. Retinal photography using FOP camera is effective for screening and diagnosis of DR and STDR with high sensitivity and specificity and has substantial agreement with conventional retinal photography.

  8. Validation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening.

    Directory of Open Access Journals (Sweden)

    Ramachandran Rajalakshmi

    Full Text Available To evaluate the sensitivity and specificity of "fundus on phone' (FOP camera, a smartphone based retinal imaging system, as a screening tool for diabetic retinopathy (DR detection and DR severity in comparison with 7-standard field digital retinal photography.Single-site, prospective, comparative, instrument validation study.301 patients (602 eyes with type 2 diabetes underwent standard seven-field digital fundus photography with both Carl Zeiss fundus camera and indigenous FOP at a tertiary care diabetes centre in South India. Grading of DR was performed by two independent retina specialists using modified Early Treatment of Diabetic Retinopathy Study grading system. Sight threatening DR (STDR was defined by the presence of proliferative DR(PDR or diabetic macular edema. The sensitivity, specificity and image quality were assessed.The mean age of the participants was 53.5 ±9.6 years and mean duration of diabetes 12.5±7.3 years. The Zeiss camera showed that 43.9% had non-proliferative DR(NPDR and 15.3% had PDR while the FOP camera showed that 40.2% had NPDR and 15.3% had PDR. The sensitivity and specificity for detecting any DR by FOP was 92.7% (95%CI 87.8-96.1 and 98.4% (95%CI 94.3-99.8 respectively and the kappa (ĸ agreement was 0.90 (95%CI-0.85-0.95 p<0.001 while for STDR, the sensitivity was 87.9% (95%CI 83.2-92.9, specificity 94.9% (95%CI 89.7-98.2 and ĸ agreement was 0.80 (95%CI 0.71-0.89 p<0.001, compared to conventional photography.Retinal photography using FOP camera is effective for screening and diagnosis of DR and STDR with high sensitivity and specificity and has substantial agreement with conventional retinal photography.

  9. Hydroxychloroquine Induced Retinopathy: A Case Series

    Directory of Open Access Journals (Sweden)

    Maryam Mobini

    2016-10-01

    Full Text Available Background and Purpose: Occular toxicity is one of the most important complications of Hydroxychloroquine. Not any type of treatment has so far been found and recommended for this disorder. The purpose of this study was to report some characteristics of patients with Hydroxychloroquine Induced Retinopathy.    Materials and Methods: From 107 patients with rheumatoid arthritis (RA and/or systemic lupus erythematosus (SLE during 2013-14 in Sari, Iran, who were selected by a simple sampling method and were referred to hospitals for ophthalmologic examinations, 21 patients were found with HCQ induced retinopathy. The Examination for HCQ-induced maculopathy was performed through fundoscopy, perimetry or optical coherence tomography (OCT, and the physicians had their own discretion based on the examination. Although the patients were examined by different ophthalmologists, all of them were evaluated by the same device (Zeiss cirrus HD OCT4000.USA for OCT, Zeiss Humphrey Field analyzer 2i. USA for visual field, and Topcon. TRC.50Dx. Japan for angiography. Based on the collected data, the characteristics of clinical and ophthalmologic changes were reported, and the data were analysed through Independent Sample t Test and χ2.    Results: 21 patients (19 females with a mean age of 49.86 (±15.6 were evaluated during 4.95 (±4.7 years of therapy. The mean of cumulative dose was calculated to be 313.18±269.8 grams. Based on the findings, hypertension was detected in 5 (23.8% of the patients. Conclusion: In the present study, it was found that HCQ induced retinal toxicity may occur even in recommended doses or for less than 5 years. Other risk factors such as hypertension in addition to the dose or duration of toxicity could also accelerate retinal toxicity.

  10. The Role of the Modern Planetarium as an Effective Tool in Astronomy Education and Public Outreach

    Science.gov (United States)

    Albin, Edward F.

    2016-01-01

    As the planetarium approaches its 100th anniversary, today's planetarium educator must reflect on the role of such technology in contemporary astronomy education and outreach. The projection planetarium saw "first light" in 1923 at the Carl Zeiss factory in Jena, Germany. During the 20th century, the concept of a star projector beneath a dome flourished as an extraordinary device for the teaching of astronomy. The evolution of digital technology over the past twenty years has dramatically changed the perception / utilization of the planetarium. The vast majority of modern star theaters have shifted entirely to fulldome digital projection systems, abandoning the once ubiquitous electromechanical star projector altogether. These systems have evolved into ultra-high resolution theaters, capable of projecting imagery, videos, and any web-based media onto the dome. Such capability has rendered the planetarium as a multi-disciplinary tool, broadening its educational appeal to a wide variety of fields -- including life sciences, the humanities, and even entertainment venues. However, we suggest that what is at the heart of the planetarium appeal is having a theater adept at projecting a beautiful / accurate star-field. To this end, our facility chose to keep / maintain its aging Zeiss V star projector while adding fulldome digital capability. Such a hybrid approach provides an excellent compromise between presenting state of the art multimedia while at the same time maintaining the ability to render a stunning night sky. In addition, our facility maintains two portable StarLab planetariums for outreach purposes, one unit with a classic electromechanical star projector and the other having a relatively inexpensive fulldome projection system. With a combination of these technologies, it is possible for the planetarium to be an effective tool for astronomical education / outreach well into the 21st century.

  11. Comparison of screen-film combinations: results of a contrast detail study and interactive image quality analysis. Pt. 2. Linear assessment of grey scale ranges with interactive (automatic) image analysis

    International Nuclear Information System (INIS)

    Stamm, G.; Eichbaum, G.; Hagemann, G.

    1997-01-01

    The following three screen-film combinations were compared: (a) A combination of anticross-over film and UV-light emitting screens, (b) a combination of blue-light emitting screens and film, and (c) a conventional green fluorescing screen-film combination. Radiographs of a specially designed plexiglass phantom (0.2x0.2x0.12 m 3 ) with bar patterns of lead and plaster and of air, respectively were obtained using the following parameters: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminium prefilter, a grid with 40 lines/cm (12:1) and a focus-detector distance of 1.15 m. Image analysis was performed using an IBAS system and a Zeiss Kontron computer. Display conditions were the following: Display distance 0.12 m, a vario film objective 35/70 (Zeiss), a video camera tube with a Pb0 photocathode, 625 lines (Siemens Heimann), an IBAS image matrix of 512x512 pixels with a resolution of 7 lines/mm, the projected matrix area was 5000 μm 2 . Grey scale ranges were measured on a line perpendicular to the grouped bar patterns. The difference between the maximum and minimum density value served as signal. The spatial resolution of the detector system was measured when the signal value was three times higher than the standard deviation of the means of multiple density measurements. The results showed considerable advantages of the two new screen-film combinations as compared to the conventional screen-film combination. The result was contradictory to the findings with pure visual assessment of thresholds (part I) that had found no differences. The authors concluded that (automatic) interactive image analysis algorithms serve as an objective measure and are specifically advantageous when small differences in image quality are to be evaluated. (orig.) [de

  12. Morfometria do tecido conjuntivo do coração de equinos PSI

    Directory of Open Access Journals (Sweden)

    Eduardo Pecorali Leite

    2004-06-01

    Full Text Available Objetivou-se, neste trabalho, estudar a proporção de tecido conjuntivo existente na fração ventricular direita e esquerda do músculo cardíaco de eqüinos da raça puro sangue inglês, buscando, através da morfometria, dados referentes à inter-relação entre o tecido conjuntivo e o tecido muscular cardíaco. Utilizaram-se corações eqüinos, machos, com idade entre 20 e 120 meses, sem alterações cardíacas. Preparou-se o material oriundo da região média do terço médio dos ventrículos, tanto da face direita quanto da esquerda, segundo as técnicas histológicas convencionais e corados com Picrosirius red, Fucsina-Paraldeido associada ao Tricromo de Gomori e Tricromo de Masson, para evidenciação das fibras conjuntivas. As lâminas foram analisadas com auxílio do Axioscópio Zeiss® acoplado ao programa de análise de imagens KS-400 Zeiss. A quantidade de tecido conjuntivo no Ventrículo Esquerdo variou de 0,008 a 24,695%; no Ventrículo Direito variou de 0,029 a 20,921%; nos corações de eqüinos da raça puro sangue inglês. Os resultados obtidos mostram que há uma complexa rede de fibras conjuntivas envolvendo as fibras do tecido muscular cardíaco e que sua quantidade e disposição é muito variada, dependendo da região estudada, animais mais jovens exibem baixa quantidade de tecido conjuntivo, também dependendo de sua atividade física.

  13. The efficiency of aspheric intraocular lens according to biometric measurements.

    Science.gov (United States)

    Whang, Woong-Joo; Piao, Junjie; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2017-01-01

    To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm (CT ASPHINA 509M; Carl Zeiss Meditec Inc., Germany). The IOLMaster (version 5.0; Carl Zeiss AG, Germany) was used for preoperative biometric measurements (axial length, anterior chamber depth, central corneal power) and the measurement of postoperative anterior chamber depth. The spherical aberrations were measured preoperatively and 3 months postoperatively using the iTrace (Tracey Technologies, Houston, TX, USA) at a pupil diameter of 5.0 mm. We investigated the relationships between preoperative biometric data and postoperative internal spherical aberration, and compared biometric measurements between 2 subgroups stratified according to internal spherical aberration (spherical aberration ≤ -0.06 μm vs. spherical aberration > -0.06 μm). The mean postoperative internal spherical aberration was -0.087 ± 0.063 μm. Preoperative axial length and residual total spherical aberration showed statistically significant correlations with internal spherical aberration (p = 0.041, 0.002). Preoperative axial length, postoperative anterior chamber depth, IOL power, and residual spherical aberration showed significant differences between the 2 subgroups stratified according to internal spherical aberration (p = 0.020, 0.029, 0.048, 0.041 respectively). The corrective effect of an aspheric IOL is influenced by preoperative axial length and postoperative anterior chamber depth. Not only the amount of negative spherical aberration on the IOL surface but also the preoperative axial length should be considered to optimize spherical aberration after aspheric IOL implantation.

  14. Quantum interference oscillations of the superparamagnetic blocking in an Fe8 molecular nanomagnet

    OpenAIRE

    Burzurí, E.; Luis, F.; Montero, O.; Barbara, B.; Ballou, R.; Maegawa, S.

    2013-01-01

    We show that the dynamic magnetic susceptibility and the superparamagnetic blocking temperature of an Fe8 single molecule magnet oscillate as a function of the magnetic field Hx applied along its hard magnetic axis. These oscillations are associated with quantum interferences, tuned by Hx, between different spin tunneling paths linking two excited magnetic states. The oscillation period is determined by the quantum mixing between the ground S=10 and excited multiplets. These experiments enabl...

  15. Quantum Interference Oscillations of the Superparamagnetic Blocking in an Fe8 Molecular Nanomagnet

    Science.gov (United States)

    Burzurí, E.; Luis, F.; Montero, O.; Barbara, B.; Ballou, R.; Maegawa, S.

    2013-08-01

    We show that the dynamic magnetic susceptibility and the superparamagnetic blocking temperature of an Fe8 single molecule magnet oscillate as a function of the magnetic field Hx applied along its hard magnetic axis. These oscillations are associated with quantum interferences, tuned by Hx, between different spin tunneling paths linking two excited magnetic states. The oscillation period is determined by the quantum mixing between the ground S=10 and excited multiplets. These experiments enable us to quantify such mixing. We find that the weight of excited multiplets in the magnetic ground state of Fe8 amounts to approximately 11.6%.

  16. High-field torque magnetometry for investigating magnetic anisotropy in Mn12-acetate nanomagnets

    International Nuclear Information System (INIS)

    Cornia, Andrea; Affronte, Marco; Gatteschi, Dante; Jansen, Aloysius G.M.; Caneschi, Andrea; Sessoli, Roberta

    2001-01-01

    The single-molecule superparamagnet [Mn 12 O 12 (OAc) 16 (H 2 O) 4 ]·2AcOH·4H 2 O (Mn 12 -acetate) has attracted considerable attention because it shows exceedingly slow paramagnetic relaxation at low temperature. The cluster has S 4 symmetry in the solid state and comprises four Mn(IV) ions (S=((3)/(2))) and eight Mn(III) ions (S=2) which are magnetically coupled to give an S=10 ground state. The ground manifold is largely split in zero magnetic field and many efforts have been spent to determine the zero-field splitting (zfs) parameters α, β and γ appearing in the fourth-order spin-Hamiltonian H=αS z 2 +βS z 4 +γ(S + 4 +S - 4 )+μ B B·g·S. These are of paramount importance for defining the magnetic anisotropy of the cluster, which in turn determines the slow relaxation of the magnetization and quantum tunneling effects at low temperatures. We want to show that cantilever torque magnetometry in high fields is a suitable technique for determining second- and fourth-order anisotropic contributions in high-spin molecules, such as Mn 12 -acetate. The main advantage of the method lies in its high sensitivity which allows to use very small single crystals. Torque curves have been recorded at 4.2 K by applying the magnetic field (0-28 T) very close to the ab-plane of the tetragonal unit cell. The zfs parameters obtained by this procedure [α=-0.389(5) cm -1 and β=-8.4(5)x10 -4 cm -1 ] are in excellent agreement with those determined by spectroscopic techniques, such as high-frequency EPR and inelastic neutron scattering

  17. Improved longitudinal magneto-optic Kerr effect signal contrast from nanomagnets with dielectric coatings

    Science.gov (United States)

    Holiday, L. F.; Gibson, U. J.

    2006-12-01

    We report on the use of dielectric coatings to improve the contrast of longitudinal magneto-optic Kerr effect signals from submicron magnetic structures. Electron-beam lithography was used to define disks in 22 nm thick Ni films deposited on Si substrates. The structures were measured in four configurations: as-deposited, through a fused silica prism using index-matching fluid, coated with ZnS, and using a prism on top of the ZnS layer. The modified samples show up to 20 times improvement in the MOKE contrast due to admittance matching to the magnetic material and suppression of the substrate reflectance. The behavior is successfully predicted by a model that includes the magneto-optic response of the nickel layer and accounts for the fraction of the beam intercepted by the magnetic structure.

  18. [Morphometrical analyze of the middle cerebral artery system at the 13-15 weeks fetuses].

    Science.gov (United States)

    Macovei, Georgeta Nataşa; Varlam, H; St Antohe, D

    2002-01-01

    Tele-encephalization process is accompanied by the appearance and progressive complication of the middle cerebral artery system. The aim of our study is to analyze the morphometrical parameters of the middle cerebral artery branches in the beginning of the edification of its system. We used 162 cerebral hemispheres from 88 fetuses aged of 13-15 weeks. Middle cerebral artery system was injected with a gelatin-China ink mixture and images recorded by means of a Zeiss surgical microscope. Parameters evaluation (length, proximal and distal diameters, external surface, volume, angles of bifurcation) was realized with KS-300 program. At this early age middle cerebral artery system has only 4-5 generations of branches usually resulting from acute angle bifurcations.

  19. PREFACE: The International Conference on Superconductivity and Magnetism (ICSM2008) (Side, Turkey, 25-29 August 2008) The International Conference on Superconductivity and Magnetism (ICSM2008) (Side, Turkey, 25-29 August 2008)

    Science.gov (United States)

    Gencer, Ali; Grasso, Gianni

    2009-03-01

    generous contributions from Turkish research institutions, and an Italian firm, Columbus Superconductors SpA. The list of contributors is as follows: TÜBİTAK Boren Columbus Superconductors Ankara University Research Fund. The following small research companies also contributed: Boronsan IMTEK Zeiss Nanomagnetics Optomek Side Municipality Belek Municipality. It is a pleasure to thank them all for their pivotal role in the organization of the conference. We would also like to thank the speakers, the participants, the exhibitors and the Ankara University staff and students for their efforts which made ICSM2008 a very successful meeting. The list of people involved in the organization is given below. More information about the conference can be found at http://www.icsm2008side.org. It is due to the immense demand from most of the attendees that we are planning to organize the second International Conference on Superconductivity and Magnetism (ICSM2010) for April 2010, in Antalya. Further details will be made clear and circulated soon. We will be very happy to host the next conference and look forward to welcoming you again. Conference Director A Gencer Ankara University Conference Co-directors B Aktas GYTE, Gebze M E Yakinci Inonu University Scientific Committee D Abukay IYTE, İzmir M Altunbas KTU, Trabzon I Askerzade Ankara University I Belenli AIBU, Bolu G Grasso Columbus Superconductors SpA, Genova N Guclu G O Pasa University K Kiymac Çukurova University S Nezir Kirikkale University A Oral Sabanci University B Ozcelik Çukurova University Y Oner IYTE, İzmir L Ozyuzer IYTE, İzmir O Uzun G O Pasa University E Yanmaz KTU, Trabzon—Coordinator C Terzioglu AIBU, Bolu International Advisory Board M Tachiki Tokyo University E Aksu TAEK H Akalin Renko O Atiker Boronsan R Cubitt Institut Laue-Langevin, Grenoble G Crabtree Argonne National Laboratory A Elmali Ankara University C Ferdeghini CNR INFM, Genova R Flukiger Genova University W Goldacker FZ Karlsruhe C E Gough

  20. PREFACE: International Conference on Superconductivity and Magnetism-ICSM2008

    Science.gov (United States)

    Gencer, Ali; Grasso, Gianni

    2009-03-01

    generous contributions from Turkish research institutions, and an Italian firm, Columbus Superconductors SpA. The list of contributors is as follows: TÜBİTAK Boren Columbus Superconductors Ankara University Research Fund. The following small research companies also contributed: Boronsan IMTEK Zeiss Nanomagnetics Optomek Side Municipality Belek Municipality. It is a pleasure to thank them all for their pivotal role in the organization of the conference. We would also like to thank the speakers, the participants, the exhibitors and the Ankara University staff and students for their efforts which made ICSM2008 a very successful meeting. The list of people involved in the organization is given below. More information about the conference can be found at http://www.icsm2008side.org. It is due to the immense demand from most of the attendees that we are planning to organize the second International Conference on Superconductivity and Magnetism (ICSM2010) for April 2010, in Antalya. Further details will be made clear and circulated soon. We will be very happy to host the next conference and look forward to welcoming you again. Conference Director A Gencer Ankara University Conference Co-directors B Aktas GYTE, Gebze M E Yakinci Inonu University Conference photograph Scientific Committee D Abukay IYTE, İzmir M Altunbas KTU, Trabzon I Askerzade Ankara University I Belenli AIBU, Bolu G Grasso Columbus Superconductors SpA, Genova N Guclu G O Pasa University K Kiymac Çukurova University S Nezir Kirikkale University A Oral Sabanci University B Ozcelik Çukurova University Y Oner IYTE, İzmir L Ozyuzer IYTE, İzmir O Uzun G O Pasa University E Yanmaz KTU, Trabzon—Coordinator C Terzioglu AIBU, Bolu International Advisory Board M Tachiki Tokyo University E Aksu TAEK H Akalin Renko O Atiker Boronsan R Cubitt Institut Laue-Langevin, Grenoble G Crabtree Argonne National Laboratory A Elmali Ankara University C Ferdeghini CNR INFM, Genova R Flukiger Genova University W Goldacker FZ

  1. High-Frequency Dynamics Modulated by Collective Magnetization Reversal in Artificial Spin Ice

    Energy Technology Data Exchange (ETDEWEB)

    Jungfleisch, Matthias B.; Sklenar, Joseph; Ding, Junjia; Park, Jungsik; Pearson, John E.; Novosad, Valentine; Schiffer, Peter; Hoffmann, Axel

    2017-12-01

    Spin-torque ferromagnetic resonance arises in heavy metal-ferromagnet heterostructures when an alternating charge current is passed through the bilayer stack. The methodology to detect the resonance is based on the anisotropic magnetoresistance, which is the change in the electrical resistance due to different orientations of the magnetization. In connected networks of ferromagnetic nanowires, known as artificial spin ice, the magnetoresistance is rather complex owing to the underlying collective behavior of the geometrically frustrated magnetic domain structure. Here, we demonstrate spin-torque ferromagnetic resonance investigations in a square artificial spin-ice system and correlate our observations to magneto-transport measurements. The experimental findings are described using a simulation approach that highlights the importance of the correlated dynamics response of the magnetic system. Our results open the possibility of designing reconfigurable microwave oscillators and magnetoresistive devices based on connected networks of nanomagnets.

  2. Investigation of spin-polarized transport in GaAs nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Tierney, B D; Day, T E; Goodnick, S M [Department of Electrical Engineering and Center for Solid State Electronics Research Arizona State University, Tempe, AZ 85287-5706 (United States)], E-mail: brian.tierney@asu.edu

    2008-03-15

    A spin field effect transistor (spin-FET) has been fabricated that employs nanomagnets as components of quantum point contact (QPC) structures to inject spin-polarized carriers into the high-mobility two-dimensional electron gas (2DEG) of a GaAs quantum well and to detect them. A centrally-placed non-magnetic Rashba gate controls both the density of electrons in the 2DEG and the electronic spin precession. Initial results are presented for comparable device structures modeled with an ensemble Monte Carlo (EMC) method. In the EMC the temporal and spatial evolution of the ensemble carrier spin polarization is governed by a spin density matrix formalism that incorporates the Dresselhaus and Rashba contributions to the D'yakanov-Perel spin-flip scattering mechanism, the predominant spin scattering mechanism in AlGaAs/GaAs heterostructures from 77-300K.

  3. High-Frequency Dynamics Modulated by Collective Magnetization Reversal in Artificial Spin Ice

    Science.gov (United States)

    Jungfleisch, Matthias B.; Sklenar, Joseph; Ding, Junjia; Park, Jungsik; Pearson, John E.; Novosad, Valentine; Schiffer, Peter; Hoffmann, Axel

    2017-12-01

    Spin-torque ferromagnetic resonance arises in heavy metal-ferromagnet heterostructures when an alternating charge current is passed through the bilayer stack. The methodology to detect the resonance is based on the anisotropic magnetoresistance, which is the change in the electrical resistance due to different orientations of the magnetization. In connected networks of ferromagnetic nanowires, known as artificial spin ice, the magnetoresistance is rather complex owing to the underlying collective behavior of the geometrically frustrated magnetic domain structure. Here, we demonstrate spin-torque ferromagnetic resonance investigations in a square artificial spin-ice system and correlate our observations to magnetotransport measurements. The experimental findings are described using a simulation approach that highlights the importance of the correlated dynamics response of the magnetic system. Our results open the possibility of designing reconfigurable microwave oscillators and magnetoresistive devices based on connected networks of nanomagnets.

  4. Magnetic model for Mn{sub 2}La{sub 2} developed from spectroscopic studies with inelastic neutron scattering and frequency-domain Fourier-transform THz EPR

    Energy Technology Data Exchange (ETDEWEB)

    Milazzo, R.; Nehrkorn, J.; Stuiber, S.; Waldmann, O. [Physikalisches Institut, Universitaet Freiburg (Germany); Akhtar, M.N.; Lan, Y.; Powell, A.K. [Institut fuer Anorganische Chemie, Universitaet Karlsruhe, KIT (Germany); Mutka, H. [Institut Laue Langevin, Grenoble (France); Dreiser, J. [Swiss Light Source, Paul Scherrer Institut (Switzerland); Schnegg, A. [Helmholtz-Zentrum Berlin, Institut fuer Silizium-Photovoltaik (Germany); Holldack, K. [Helmholtz-Zentrum Berlin, Institut fuer Synchrotonstrahlung (Germany)

    2011-07-01

    Molecular nanomagnets which contain several magnetic centers with a large single-ion magnetic anisotropy are of general interest, because they could lead to interesting phenomena such as single-molecule magnet (SMM) behavior. We performed spectroscopic experiments on Mn{sub 2}La{sub 2} using inelastic neutron scattering at the direct time-of-flight disc chopper spectrometer IN5 at ILL and the newly developed frequency-domain Fourier-transform THz EPR at BESSY. Based on the experimental results a magnetic model has been developed. It is discussed why no SMM behavior was observed, even though Mn{sub 2}La{sub 2} exhibits a remarkably high energy barrier of about 37 K for spin relaxation. Furthermore our results can be applied to analogous clusters, with the diamagnetic La{sup I}II ions replaced by magnetic rare earth ions.

  5. Disorder effects in Mn(12)-acetate at 83 K.

    Science.gov (United States)

    Cornia, Andrea; Fabretti, Antonio Costantino; Sessoli, Roberta; Sorace, Lorenzo; Gatteschi, Dante; Barra, Anne-Laure; Daiguebonne, Carole; Roisnel, Thierry

    2002-07-01

    The structure of hexadeca-mu-acetato-tetraaquadodeca-mu(3)-oxo-dodecamanganese bis(acetic acid) tetrahydrate, [Mn(12)O(12)(CH(3)COO)(16)(H(2)O)(4)] x 2CH(3)COOH x 4H(2)O, known as Mn(12)-acetate, has been determined at 83 (2) K by X-ray diffraction methods. The fourfold (S(4)) molecular symmetry is disrupted by a strong hydrogen-bonding interaction with the disordered acetic acid molecule of solvation, which displaces one of the acetate ligands in the cluster. Up to six Mn(12) isomers are potentially present in the crystal lattice, which differ in the number and arrangement of hydrogen-bonded acetic acid molecules. These results considerably improve the structural information available on this molecular nanomagnet, which was first synthesized and characterized by Lis [Acta Cryst. (1980), B36, 2042-2046].

  6. Interacting adiabatic quantum motor

    Science.gov (United States)

    Bruch, Anton; Kusminskiy, Silvia Viola; Refael, Gil; von Oppen, Felix

    2018-05-01

    We present a field-theoretic treatment of an adiabatic quantum motor. We explicitly discuss a motor called the Thouless motor which is based on a Thouless pump operating in reverse. When a sliding periodic potential is considered to be the motor degree of freedom, a bias voltage applied to the electron channel sets the motor in motion. We investigate a Thouless motor whose electron channel is modeled as a Luttinger liquid. Interactions increase the gap opened by the periodic potential. For an infinite Luttinger liquid the coupling-induced friction is enhanced by electron-electron interactions. When the Luttinger liquid is ultimately coupled to Fermi liquid reservoirs, the dissipation reduces to its value for a noninteracting electron system for a constant motor velocity. Our results can also be applied to a motor based on a nanomagnet coupled to a quantum spin Hall edge.

  7. Near-infrared-responsive, superparamagnetic Au@Co nanochains

    Directory of Open Access Journals (Sweden)

    Varadee Vittur

    2017-08-01

    Full Text Available This manuscript describes a new type of nanomaterial, namely superparamagnetic Au@Co nanochains with optical extinctions in the near infrared (NIR. The Au@Co nanochains were synthesized via a one-pot galvanic replacement route involving a redox-transmetalation process in aqueous medium, where Au salt was reduced to form Au shells on Co seed templates, affording hollow Au@Co nanochains. The Au shells serve not only as a protective coating for the Co nanochain cores, but also to give rise to the optical properties of these unique nanostructures. Importantly, these bifunctional, magneto-optical Au@Co nanochains combine the advantages of nanophotonics (extinction at ca. 900 nm and nanomagnetism (superparamagnetism and provide a potentially useful new nanoarchitecture for biomedical or catalytic applications that can benefit from both activation by light and manipulation using an external magnetic field.

  8. Short-Range Correlated Magnetic Core-Shell CrO2/Cr2O3 Nanorods: Experimental Observations and Theoretical Considerations

    Directory of Open Access Journals (Sweden)

    Ashish C. Gandhi

    2018-05-01

    Full Text Available With the evolution of synthesis and the critical characterization of core-shell nanostructures, short-range magnetic correlation is of prime interest in employing their properties to develop novel devices and widespread applications. In this regard, a novel approach of the magnetic core-shell saturated magnetization (CSSM cylinder model solely based on the contribution of saturated magnetization in one-dimensional CrO2/Cr2O3 core-shell nanorods (NRs has been developed and applied for the determination of core-diameter and shell-thickness. The nanosized effect leads to a short-range magnetic correlation of ferromagnetic core-CrO2 extracted from CSSM, which can be explained using finite size scaling method. The outcome of this study is important in terms of utilizing magnetic properties for the critical characterization of core-shell nanomagnetic materials.

  9. Proceedings of the second national seminar on new materials research and nanotechnology

    International Nuclear Information System (INIS)

    Joseph John, N.

    2013-01-01

    The contents of the presentations cover new materials, advanced materials, biomaterials, carbon nanomaterials, computational material science, diamond and diamond related materials, electronic materials, ferroelectric materials, fiber optics, fluorescent materials, functional materials, inorganic materials, lasers materials processing, laser and plasma technology, luminescence materials, magnetic and superconducting materials, materials for defence applications, mesoporous materials, materials for solar energy and energy storing devices, NLO materials, organic materials/electronics, photonic materials, piezoelectric materials, semiconductor materials, smart materials, nanomaterials and composites, nanoelectronics and spintronics, environment and nanotechnology, nano environmental devices, nano fluids, nanobiotechnology, nanomedicine, nanomagnetism, nanopharmacy, sensors, nano sensors/actuatoes, nanotechnology for hill area development, simulation and modeling of nanodevices, crystals, crystal growth, crystal growth methods, characterization techniques, crystal defects, liquid crystals, optoelectronic crystals, polymers, polymer composites, nano polymers, spectroscopy, thin films, deposition, characterization, applications and ultrasonics. Papers relevant to INIS are indexed separately. (author)

  10. Magnetic x-ray microdiffraction

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Paul G [Computer-Aided Engineering Center, University of Wisconsin, Madison, WI 53706 (United States); Isaacs, Eric D [Center for Nanoscale Materials, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2006-08-07

    Magnetic x-ray microdiffraction uses the structural specificity of x-ray diffraction to probe complex magnetic structures at the length scales relevant to physical phenomena including domain dynamics and phase transitions. Conventional magnetic crystallography techniques such as neutron or x-ray diffraction lack this spatial resolution. The combination of both reciprocal space and real space resolution with a rich magnetic cross section allows new microscopy techniques to be developed and applied to magnetism at the scale of single domains. Potential applications include a wide range of magnetic problems in nanomagnetism, the interaction of strain, polarization and magnetization in complex oxides and spatially resolved studies of magnetic phase transitions. We present the physical basis for x-ray microdiffraction and magnetic scattering processes, review microdiffraction domain imaging techniques in antiferromagnetic and ferromagnetic materials and discuss potential directions for studies. (topical review)

  11. Magnetic droplets in nano-contact spin-torque oscillators with perpendicular magnetic anisotropy

    Science.gov (United States)

    Åkerman, Johan

    2013-03-01

    The theoretical prediction, by Ivanov and Kosevich, of ``magnon drop'' solitons in thin films with perpendicular magnetic anisotropy (PMA) and zero damping, dates back to the 1970s. More recently, Hoefer, Silva and Keller, demonstrated analytically and numerically that related ``magnetic droplet'' solitons should be possible to excite in nano-contact spin-torque oscillators (NC-STOs) based on PMA materials, where spin transfer torque locally realizes the zero-damping condition required in. In my talk, I will present the first experimental demonstration of such magnetic droplets, realized using 50-100 nm diameter nano-contacts (NCs) fabricated on top of orthogonal GMR stacks of Co8/Cu/Co0.3[Ni0.8/Co0.4]x4 (thicknesses in nm). The nucleation of a magnetic droplet manifests itself as a dramatic 10 GHz drop in microwave signal frequency at a drive-current dependent critical perpendicular field of the order of 0.5 - 1 T. The drop in frequency is accompanied by a simultaneous sharp resistance increase of the device and a sign change of its magnetoresistance, directly indicating the existence of a reversed magnetization in a region of the [Co/Ni] free layer underneath the NC. As predicted by numerical simulations the droplet exhibits rich magnetodynamic properties, experimentally observed as auto-modulation at approximately 1 GHz and sometimes sidebands at 1/2 and 3/2 of the fundamental droplet frequency. The 1 GHz modulation can be shown numerically to be related to the drift instability of the droplet, albeit with enough restoring force to make the droplet perform a periodic motion instead of leaving the NC region. The sidebands at 1/2 and 3/2 the droplet frequency are related to eigenmodes of the droplet perimeter. Magnetic droplet nucleation is found to be robust and reproducible over a wide number of NC-STOs with different NC sizes, making this new nanomagnetic object as fundamental and potentially useful to nanomagnetism as e.g. domain walls and vortices. Support

  12. Studying fatigue damage evolution in uni-directional composites using x-ray computed tomography

    DEFF Research Database (Denmark)

    Mikkelsen, Lars Pilgaard

    , it will be possible to lower the costs of energy for wind energy based electricity. In the present work, a lab-source x-ray computed tomography equipment (Zeiss Xradia 520 Versa) has been used in connection with ex-situ fatigue testing of uni-directional composites in order to identify fibre failure during...... comparable x-ray studies) have been used in order to ensure a representative test volume during the ex-situ fatigue testing. Using the ability of the x-ray computed tomography to zoom into regions of interest, non-destructive, the fatigue damage evolution in a repeating ex-situ fatigue loaded test sample has...... improving the fatigue resistance of non-crimp fabric used in the wind turbine industry can be made....

  13. Revealing fatigue damage evolution in unidirectional composites for wind turbine blades using x-ray computed tomography

    DEFF Research Database (Denmark)

    Mikkelsen, Lars Pilgaard

    ’. Thereby, it will be possible to lower the cost of energy for wind energy based electricity. In the presented work, a lab-source x-ray computed tomography equipment (Zeiss Xradia 520 Versa) has been used in connection with ex-situ fatigue testing of uni-directional composites in order to identify fibre...... to other comparable x-ray studies) have been used in order to ensure a representative test volume during the ex-situ fatigue testing. Using the ability of the x-ray computed tomography to zoom into regions of interest, non-destructive, the fatigue damage evolution in a repeating ex-situ fatigue loaded test...... improving the fatigue resistance of non-crimp fabric used in the wind turbine industry can be made....

  14. Digital Archive of the Astrograph Plates Stored at the Inasan Zvenigorod Observatory

    Directory of Open Access Journals (Sweden)

    Vereshchagin S. V.

    2012-09-01

    Full Text Available The plate collection of the Zvenigorod 40-cm Carl Zeiss astrograph, obtained in 1972-2003, contains direct photographs of star fields, comets, asteroids, Pluto, and Mars. The electronic library of images from photographic plates was created from scanning the astronomical negatives. We present information on programs scheduled at the telescope and the structure and maintenance of the plate stacks. We also list the plates with images of asteroids and comets. Access to all our plate lists is provided at the web sites of the Institute of Astronomy (INASAN and WFPDB. It is possible to select plates by the date of observation, by the coordinates of the sky area, by the object type. Preview images can be inspected.

  15. Comportamiento de la cromósfera solar en la línea H-alpha durante el ciclo 23

    Science.gov (United States)

    Davoli, D.; Aquilano, R.; Missio, H.

    Using the instrumental of the Observatorio Astronómico Municipal de Rosario (OAMR), we analyze the solar chromospheric activity during an approximate period of 11 years. The instrument is a Carl Zeiss refractor telescope of 150 mm aperture and 2250 mm of focal distance with monochromatic filter in the H-alpha line. We take as proxy for the solar activity the area covered by chromospheric plages. Simultaneously, we determine the relative wolf number from observations of the solar photosphere. We describe our technique and the results obtained. We observe 2 maxima of solar activity in the years 2000 and 2001 respectively, and a later decrease of this activity with low average values starting around 2006 that corresponds to the end of cycle 23. FULL TEXT IN SPANISH

  16. Automation of technological processes at surface mines in the GDR as one of the main directions of increased coal extraction effectiveness by surface mining

    Energy Technology Data Exchange (ETDEWEB)

    Jona, U.

    1987-12-01

    In the GDR, about 53% of brown coal is mined with the use of overburden conveyor bridges, 27% with the use of belt conveyors, and 20% with the use of rail transport. Compares efficiency and cost per 1 m/sup 3/ of these transport methods. The overburden conveyor bridges, their specifications and microcomputer control are described. Describes utilization of microcomputer techniques, especially the stereochart system of Carl Zeiss Jena, for automated processing of data on surface mine geometry. Other computer applications are also presented, e.g. for surveying, slope stability calculation, and conveyor bridge control. Maintains that application of the KED/KEM microcomputer system for overburden conveyor bridge control increases its effectiveness by 10%, i.e. by 8 million m/sup 3//a.

  17. Prize for Industrial Applications of Physics Talk: Low energy spread Ion source for focused ion beam systems-Search for the holy grail

    Science.gov (United States)

    Ward, Bill

    2011-03-01

    In this talk I will cover my personal experiences as a serial entrepreneur and founder of a succession of focused ion beam companies (1). Ion Beam Technology, which developed a 200kv (FIB) direct ion implanter (2). Micrion, where the FIB found a market in circuit edit and mask repair, which eventually merged with FEI corporation. and (3). ALIS Corporation which develop the Orion system, the first commercially successful sub-nanometer helium ion microscope, that was ultimately acquired by Carl Zeiss corporation. I will share this adventure beginning with my experiences in the early days of ion beam implantation and e-beam lithography which lead up to the final breakthrough understanding of the mechanisms that govern the successful creation and operation of a single atom ion source.

  18. Microstructure and Service Properties of Copper Alloys

    Directory of Open Access Journals (Sweden)

    Polok-Rubiniec M.

    2016-09-01

    Full Text Available This elaboration shows the effect of combined heat treatment and cold working on the structure and utility properties of alloyed copper. As the test material, alloyed copper CuTi4 was employed. The samples were subjected to treatment according to the following schema: 1st variant – supersaturation and ageing, 2nd variant – supersaturation, cold rolling and ageing. The paper presents the results of microstructure, hardness, and abrasion resistance. The analysis of the wipe profile geometry was realized using a Zeiss LSM 5 Exciter confocal microscope. Cold working of the supersaturated solid solution affects significantly its hardness but the cold plastic deformation causes deterioration of the wear resistance of the finally aged CuTi4 alloy.

  19. Compilation of 1990 Annual Reports of the Navy ELF Communications System Ecological Monitoring Program. Volume 3. Tabs G thru I.

    Science.gov (United States)

    1991-08-01

    crowned Kinglet 12 11 1 3 5 0 0 9 3 4 i Reciulus calendula _Gnatcatcher 0 1 0 0 0 0 00 0Blue-grayGattce Polioptila caerulea Eastern Bluebird 0 0 0 0 1 0 6 0...and species determinations was done at 1250X magnification on a Zeiss microscope equipped with phase contrast illumination and an oil immersion 10OX...xx MMN M M N NŘ N NMN NM M N II~ ~ 0 a MM NM 333 30661 6961 x x x 39961 x x xK x x S996 x K K U I *c E I I. i~~ 0* oil ] o o I4 33 0) x LL 5 I. CoI

  20. A Study of Precataclysmic Binaries Through Theoretic Modeling of Light Curves and Spectra

    Science.gov (United States)

    Mitrofanova, A. A.; Shimansky, V. V.; Borisov, N. V.

    2017-06-01

    The article presents results of three pre-cataclysmic binaries (PN G068.1+11.0, TW Crv and RE J2013+4002) investigation. Spectroscopic and photometric observations were obtained on BTA and Zeiss-1000 of SAO RAS and on RTT-150. We used the modeling of light curves and spectra to determine the fundamental parameters for all three systems. The PN G068.1+11.0 parameters were obtained with the use of the evolutionary tracks for the nuclei of planetary nebulae of different masses. According to the results of the study, it was found that the secondary components of PN G068.1+11.0 and TW Crv have luminosity excess, but secondary component of RE J2013+4002 doesn't have one.

  1. Multi-directional emission and detection of spin waves propagating in yttrium iron garnet with wavelengths down to about 100 nm

    Science.gov (United States)

    Maendl, Stefan; Grundler, Dirk

    2018-05-01

    We performed broadband spin-wave spectroscopy on 200 nm thick yttrium iron garnet containing arrays of partially embedded magnetic nanodisks. Using integrated coplanar waveguides (CPWs), we studied the excitation and transmission of spin waves depending on the presence of nanomagnet arrays of different lateral extensions. By means of the grating coupler effect, we excited spin waves propagating in multiple lateral directions with wavelengths down to 111 nm. They exhibited group velocities of up to 1 km/s. Detection of such short-wavelength spin waves was possible only in symmetrically designed emitter/detector configurations, not with a bare CPW. We report spin waves propagating between grating couplers under oblique angles exhibiting a wave vector component parallel to the CPW. The effective propagation distance amounted to about 80 μm. Such transmission signals were not addressed before and substantiate the versatility of the grating coupler effect for implementing nanomagnonic circuits.

  2. Optimal spin current pattern for fast domain wall propagation in nanowires

    Science.gov (United States)

    Yan, Peng; Sun, Zhouzhou; Schliemann, John; Wang, Xiangrong

    2011-03-01

    One of the important issues in nanomagnetism is to lower the current needed for a technologically useful domain wall (DW) propagation speed. Based on the modified Landau-Lifshitz-Gilbert (LLG) equation with both Slonczewski spin-transfer torque and the field-like torque, we derive an optimal temporally and spatially varying spin current pattern for fast DW propagation along nanowires. Under such conditions, the DW velocity in biaxial wires can be enhanced as much as tens of times higher than that achieved in experiments so far. Moreover, the fast variation of spin polarization can efficiently help DW depinning. Possible experimental realizations are discussed. This work is supported by Hong Kong RGC grants (#603508, 604109, RPC10SC05 and HKU10/CRF/08-HKUST17/CRF/08), and by Deutsche Forschungsgemeinschaft via SFB 689. ZZS thanks the Alexander von Humboldt Foundation (Germany) for a grant.

  3. The need for control of magnetic parameters for energy efficient performance of magnetic tunnel junctions

    Science.gov (United States)

    Farhat, I. A. H.; Gale, E.; Alpha, C.; Isakovic, A. F.

    2017-07-01

    Optimizing energy performance of Magnetic Tunnel Junctions (MTJs) is the key for embedding Spin Transfer Torque-Random Access Memory (STT-RAM) in low power circuits. Due to the complex interdependencies of the parameters and variables of the device operating energy, it is important to analyse parameters with most effective control of MTJ power. The impact of threshold current density, Jco , on the energy and the impact of HK on Jco are studied analytically, following the expressions that stem from Landau-Lifshitz-Gilbert-Slonczewski (LLGS-STT) model. In addition, the impact of other magnetic material parameters, such as Ms , and geometric parameters such as tfree and λ is discussed. Device modelling study was conducted to analyse the impact at the circuit level. Nano-magnetism simulation based on NMAGTM package was conducted to analyse the impact of controlling HK on the switching dynamics of the film.

  4. Magneto-plasmonic nanoantennas: Basics and applications

    Directory of Open Access Journals (Sweden)

    Ivan S. Maksymov

    2016-11-01

    Full Text Available Plasmonic nanoantennas are a hot and rapidly expanding research field. Here we overview basic operating principles and applications of novel magneto-plasmonic nanoantennas, which are made of ferromagnetic metals and driven not only by light, but also by external magnetic fields. We demonstrate that magneto-plasmonic nanoantennas enhance the magneto-optical effects, which introduces additional degrees of freedom in the control of light at the nano-scale. This property is used in conceptually new devices such as magneto-plasmonic rulers, ultra-sensitive biosensors, one-way subwavelength waveguides and extraordinary optical transmission structures, as well as in novel biomedical imaging modalities. We also point out that in certain cases ‘non-optical’ ferromagnetic nanostructures may operate as magneto-plasmonic nanoantennas. This undesigned extra functionality capitalises on established optical characterisation techniques of magnetic nanomaterials and it may be useful for the integration of nanophotonics and nanomagnetism on a single chip.

  5. The influence of the edge effect on the skyrmion generation in a magnetic nanotrack

    Directory of Open Access Journals (Sweden)

    N. Ran

    2017-02-01

    Full Text Available Magnetic skyrmions might be used for building next-generation nanomagnetic and spintronic devices, as they have several perspective properties, such as topologically protected stability, nanoscale size, and ultra-low depinning current density. Here we study the influence of the edge effect on the current-induced generation of a magnetic skyrmion in a finite-length thin-film ferromagnetic nanotrack with interface-induced Dzyaloshinskii-Moriya interaction. It shows that a stable skyrmion or a bunch of skyrmions can be successfully generated as long as the distance between the current injection region and the nanotrack terminal is larger than a certain threshold. We investigate the failed skyrmion generation caused by the edge effect, which will lead to an error writing event. We also present the phase diagrams of the skyrmion generation obtained for different material and geometric parameters. Our results could be useful for designing skyrmion-based information storage devices.

  6. Fingerprint signatures based on nanomagnets as markers in materials for tracing and counterfeit protection

    International Nuclear Information System (INIS)

    Szielasko, Klaus; Youssef, Amir; Sporn, Dieter; Mandel, Karl

    2016-01-01

    Identification and tracing of objects is a challenge of great current importance. Ideally, this can be achieved via small markers, which equip an object with a fingerprint identity. Herein, we communicate an approach that is based on structural arrangements of magnetic nano-entities to generate a kind of security key in an object. The nano-markers, which are applied as inks, can remotely be read out in a fast and simple way with a GMR sensor and yield an unmistakable signal pattern.Graphical abstract

  7. High-field torque magnetometry for investigating magnetic anisotropy in Mn{sub 12}-acetate nanomagnets

    Energy Technology Data Exchange (ETDEWEB)

    Cornia, Andrea E-mail: acornia@unimo.it; Affronte, Marco; Gatteschi, Dante; Jansen, Aloysius G.M.; Caneschi, Andrea; Sessoli, Roberta

    2001-05-01

    The single-molecule superparamagnet [Mn{sub 12}O{sub 12}(OAc){sub 16}(H{sub 2}O){sub 4}]{center_dot}2AcOH{center_dot}4H{sub 2}O (Mn{sub 12}-acetate) has attracted considerable attention because it shows exceedingly slow paramagnetic relaxation at low temperature. The cluster has S{sub 4} symmetry in the solid state and comprises four Mn(IV) ions (S=((3)/(2))) and eight Mn(III) ions (S=2) which are magnetically coupled to give an S=10 ground state. The ground manifold is largely split in zero magnetic field and many efforts have been spent to determine the zero-field splitting (zfs) parameters {alpha}, {beta} and {gamma} appearing in the fourth-order spin-Hamiltonian H={alpha}S{sub z}{sup 2}+{beta}S{sub z}{sup 4}+{gamma}(S{sub +}{sup 4}+S{sub -}{sup 4})+{mu}{sub B}B{center_dot}g{center_dot}S. These are of paramount importance for defining the magnetic anisotropy of the cluster, which in turn determines the slow relaxation of the magnetization and quantum tunneling effects at low temperatures. We want to show that cantilever torque magnetometry in high fields is a suitable technique for determining second- and fourth-order anisotropic contributions in high-spin molecules, such as Mn{sub 12}-acetate. The main advantage of the method lies in its high sensitivity which allows to use very small single crystals. Torque curves have been recorded at 4.2 K by applying the magnetic field (0-28 T) very close to the ab-plane of the tetragonal unit cell. The zfs parameters obtained by this procedure [{alpha}=-0.389(5) cm{sup -1} and {beta}=-8.4(5)x10{sup -4} cm{sup -1}] are in excellent agreement with those determined by spectroscopic techniques, such as high-frequency EPR and inelastic neutron scattering.

  8. Fingerprint signatures based on nanomagnets as markers in materials for tracing and counterfeit protection

    Energy Technology Data Exchange (ETDEWEB)

    Szielasko, Klaus; Youssef, Amir [Fraunhofer Institute for Nondestructive Testing IZFP (Germany); Sporn, Dieter; Mandel, Karl, E-mail: karl-sebastian.mandel@isc.fraunhofer.de [Fraunhofer Institute for Silicate Research ISC (Germany)

    2016-05-15

    Identification and tracing of objects is a challenge of great current importance. Ideally, this can be achieved via small markers, which equip an object with a fingerprint identity. Herein, we communicate an approach that is based on structural arrangements of magnetic nano-entities to generate a kind of security key in an object. The nano-markers, which are applied as inks, can remotely be read out in a fast and simple way with a GMR sensor and yield an unmistakable signal pattern.Graphical abstract.

  9. Voltage induced magnetostrictive switching of nanomagnets: Strain assisted strain transfer torque random access memory

    International Nuclear Information System (INIS)

    Khan, Asif; Nikonov, Dmitri E.; Manipatruni, Sasikanth; Ghani, Tahir; Young, Ian A.

    2014-01-01

    A spintronic device, called the “strain assisted spin transfer torque (STT) random access memory (RAM),” is proposed by combining the magnetostriction effect and the spin transfer torque effect which can result in a dramatic improvement in the energy dissipation relative to a conventional STT-RAM. Magnetization switching in the device which is a piezoelectric-ferromagnetic heterostructure via the combined magnetostriction and STT effect is simulated by solving the Landau-Lifshitz-Gilbert equation incorporating the influence of thermal noise. The simulations show that, in such a device, each of these two mechanisms (magnetostriction and spin transfer torque) provides in a 90° rotation of the magnetization leading a deterministic 180° switching with a critical current significantly smaller than that required for spin torque alone. Such a scheme is an attractive option for writing magnetic RAM cells.

  10. Voltage induced magnetostrictive switching of nanomagnets: Strain assisted strain transfer torque random access memory

    Science.gov (United States)

    Khan, Asif; Nikonov, Dmitri E.; Manipatruni, Sasikanth; Ghani, Tahir; Young, Ian A.

    2014-06-01

    A spintronic device, called the "strain assisted spin transfer torque (STT) random access memory (RAM)," is proposed by combining the magnetostriction effect and the spin transfer torque effect which can result in a dramatic improvement in the energy dissipation relative to a conventional STT-RAM. Magnetization switching in the device which is a piezoelectric-ferromagnetic heterostructure via the combined magnetostriction and STT effect is simulated by solving the Landau-Lifshitz-Gilbert equation incorporating the influence of thermal noise. The simulations show that, in such a device, each of these two mechanisms (magnetostriction and spin transfer torque) provides in a 90° rotation of the magnetization leading a deterministic 180° switching with a critical current significantly smaller than that required for spin torque alone. Such a scheme is an attractive option for writing magnetic RAM cells.

  11. DIMENSIONAL VERIFICATION AND QUALITY CONTROL OF IMPLANTS PRODUCED BY ADDITIVE MANUFACTURING

    Directory of Open Access Journals (Sweden)

    Teodor Toth

    2015-07-01

    Full Text Available Purpose: Development of computer technology and alternative manufacturing methods in form of additive manufacturing leads to the manufacture of products with complex shapes. In the field of medicine they include, inter alia, custom-made implants manufactured for a particular patient, such as cranial implants, maxillofacial implants, etc. With regard to the fact that such implants are inserted into a patient’s body, it is necessary to perform the verification, including the shape and dimensional verification. The article deals with the application of the industrial computer tomography within the process of inspection and verification of selected custom-made implant types.Methodology/Approach: The Department of Biomedical Engineering and Measurement performs the verification of medicinal products manufactured by the additive manufacturing technologies from the Ti-6Al-4V (Grade 5 titanium alloy, using the coordinate measuring machine Carl Zeiss Contura G2 and the industrial computed tomography machine Carl Zeiss Metrotom 1500. These equipment fulfil the requirements for the identification and evaluation of dimensions of both, the external and the internal structures. Findings: The article presents the possibilities of the computed tomography utilisation in the inspection of individual implant manufacture using the additive manufacturing technologies. The results indicate that with the adjustment of appropriate input parameters (alignment, this technology is appropriate for the analysis of shape deviations, when compared with the CAD model.Research Limitation/implication: With the increasing distance of measured object from X-ray source, the machine’s resolution function decreases. Decreasing of resolution has a minor impact on the measured dimensions (relatively high tolerances, but has a significant impact on the evaluation of porosity and inclusions. Originality/Value of paper: Currently, the verification of a manufactured implant  can be

  12. [Comparison of film-screen combinations in contrast-detail diagram and with interactive image analysis. 3: Trimodal histograms of gray scale distribution in bar groups of lead pattern images].

    Science.gov (United States)

    Hagemann, G; Eichbaum, G; Stamm, G

    1998-05-01

    The following four screen film combinations were compared: a) a combination of anticrossover film and UV-light emitting screens, b) a combination of blue-light emitting screens and film and c) two conventional green fluorescing screen film combinations. Radiographs of a specially designed plexiglass phantom (0.2 x 0.2 x 0.12 m3) with bar patterns of lead and plaster and of air, respectively were obtained using the following parameters: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminum prefilter, a grid with 40 lines/cm (12:1) and a focus-detector distance of 1.15 m. Image analysis was performed using an Ibas system and a Zeiss Kontron computer. Display conditions were the following: display distance 0.12 m, a vario film objective 35/70 (Zeiss), a video camera tube with a PbO photocathode, 625 lines (Siemens Heimann), an Ibas image matrix of 512 x 512 pixels with a spatial resolution of ca. 7 cycles/mm, the projected matrix area was 5000 micron 2. Maxima in the histograms of a grouped bar pattern were estimated as mean values from the bar and gap regions ("mean value method"). They were used to calculate signal contrast, standard deviations of the means and scatter fraction. Comparing the histograms with respect to spatial resolution and kV setting a clear advantage of the UVR system becomes obvious. The quantitative analysis yielded a maximum spatial resolution of approx. 3 cycles/mm for the UVR system at 60 kV which decreased to half of this value at 117 kV caused by the increasing influence of scattered radiation. A ranking of screen-film systems with respect to image quality and dose requirement is presented. For its evaluation an interactive image analysis using the mean value method was found to be superior to signal/noise ratio measurements and visual analysis in respect to diagnostic relevance and saving of time.

  13. Optic coherence tomography in a patient with diffuse unilateral subacute neuroretinitis Tomografia de coerência óptica em neuretinite subaguda difusa unilateral

    Directory of Open Access Journals (Sweden)

    Alexandre Henrique Gomes

    2009-04-01

    Full Text Available PURPOSE: To measure retinal nervous fiber layer (RNFL thickness using OCT3 (Carl-Zeiss in patients with diffuse unilateral subacute neuroretinitis (DUSN with or without live worm and correlate it with visual acuity. METHODS: RNFL thickness, using RNFL thickness 3.4 program and best corrected visual acuity were measured in patients with DUSN between January 2005 and December 2006. RESULTS: Thirty-eight patients, aged 9 - 42 years were selected, of whom 20 had live worm. Mean RNFL was 71.55 ± 27.26 in the DUSN eye and 103.07 ± 20.66 in the contralateral eye (pOBJETIVO: Avaliar o uso do OCT3 (Carl-Zeiss para medir a espessura da camada de fibras nervosas em pacientes com neuroretinite unilateral subaguda difusa (DUSN e correlacionar com a acuidade visual. MÉTODOS: Foi medido a espessura da camada de fibras nervosas, utilizando programa "RNFL thickness 3.4" e a melhor acuidade visual de pacientes com DUSN entre janeiro de 2005 e dezembro 2006. RESULTADOS: Trinta e oito pacientes, com idade entre 9-42 anos foram selecionados para este estudo, sendo que 20 casos apresentavam larva viva localizada. A média da RNFL foi 71,55 ± 27,26 nos olhos com DUSN e 103,07 ± 20,66 nos olhos contralaterais (p<0,001. Correlação de Pearson entre a acuidade visual e a espessura da camada de fibras nervosas foi r= -0,522 (p<0,001 nos olhos com DUSN e r= -0,097 (p=0,509 nos olhos contralaterais. CONCLUSÃO: A espessura da camada de fibras nervosas de pacientes com DUSN apresenta uma correlação diretamente proporcional com a acuidade visual. Novos estudos são necessários para reforçar a correlação entre a acuidade visual e a espessura da camada de fibras nervosas nos pacientes com DUSN com a finalidade de acompanhar os pacientes após o tratamento.

  14. Spectral domain OCT versus time domain OCT in the evaluation of macular features related to wet age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Isola V

    2012-02-01

    Full Text Available Luisa Pierro1, Elena Zampedri1, Paolo Milani2, Marco Gagliardi1, Vincenzo Isola2, Alfredo Pece21Department of Ophthalmology, University Vita-Salute, Scientific Institute San Raffaele, Milano, Italy, 2Fondazione Retina 3000, Milano, ItalyBackground: The aim of this study was to compare the agreement between spectral domain optical coherence tomography (SD OCT and time domain stratus OCT (TD OCT in evaluating macular morphology alterations in wet age-related macular degeneration (AMD.Methods: This retrospective study was performed on 77 eyes of 77 patients with primary or recurring subfoveal choroidal neovascularization secondary to AMD. All patients underwent OCT examination using Zeiss Stratus OCT 3 (Carl Zeiss Meditec Inc, Dublin, CA and Opko OTI Spectral SLO/OCT (Ophthalmic Technologies Inc, Toronto, Canada. In all radial line scans, the presence of intraretinal edema (IRE, serous pigment epithelium detachment (sPED, neurosensory serous retinal detachment (NSRD, epiretinal membrane (EM, inner limiting membrane thickening (ILMT, and hard exudates (HE were evaluated. The degree of matching was quantified by Kappa measure of agreement.Results: The percentage distribution of TD OCT findings versus SD OCT findings was: IRE 36.3% versus 77.9%, sPED 57.1% versus 85.7%, NSRD 38.9% versus 53.2%, EM 10.5% versus 26.3%, ILMT 3.8% versus 32.4%, and HE 6.4% versus 54.5%. The agreement was as follows: sPED: kappa value 0.15; NSRD: kappa value 0.61; IRE: kappa value 0.18; EM: kappa value 0.41; ILMT: kappa value 0.02; HE: kappa value 0.06.Conclusion: The agreement in the evaluation of macular lesions between the two techniques is poor and depends on the lesion considered. SD OCT allows better detection of the alterations typically related to choroidal neovascularization such as IRE, PED, ILM thickening, and HE. Consequently its use should be strongly considered in patients with wet AMD.Keywords: spectral domain, OCT, time domain, macular degeneration, AMD

  15. Comparison of screen film combinations: results of a contrast detail study and interactive image quality analysis. Pt. III. Trimodal histograms of grey-value distributions found in the images of grouped lead bar pattern

    International Nuclear Information System (INIS)

    Hagemann, G.; Eichbaum, G.; Stamm, G.

    1998-01-01

    The following four screen film combinations were compared: (a) a combination of anticrossover film and UV-light emitting screens, (b) a combination of blue-light emitting screens and film and (c) two conventional green fluorescing screen film combinations. Radiographs of a specially designed plexiglass phantom (0.2 x 0.2 x 0.12 m 3 ) with bar patterns of lead and plaster and of air, respectively were obtained using the following parameters: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminum prefilter, a grid with 40 lines/cm (12:1) and a focus-detector distance of 1.15 m. Image analyses was performed using an Ibas system and a Zeiss Kontron computer. Display conditions were the following: display distance 0.12 m, a vario film objective 35/70 (Zeiss), a video camera tube with a PbO photocathode, 625 lines (Siemens Heimann), an Ibas image matrix of 512 x 512 pixels with a spatial resolution of ca. 7 cycles/mm, the projected matrix area was 5000 μm 2 . Maxima in the histograms of a grouped bar pattern were estimated as mean values from the bar and gap regions ('mean value method'). They were used to calculate signal contrast, standard deviations of the means and scatter fraction. Comparing the histograms with respect to spatial resolution and kV setting a clear advantage of the UVR system becomes obvious. The quantitative analysis yielded a maximum spatial resolution of approx. 3 cycles/mm for the UVR system at 60 kV which decreased to half of this value at 117 kV caused by the increasing influence of scattered radiation. A ranking of screen-film systems with respect to image quality and dose requirement is presented. For its evaluation an interactive image analysis using the mean value method was found to be superior to signal/noise ratio measurements and visual analysis in respect to diagnostic relevance and saving of time. (orig./MG) [de

  16. Quantificação de tecido conjuntivo do músculo cardíaco de cães

    Directory of Open Access Journals (Sweden)

    Hildebrando Gomes Benedicto

    2003-01-01

    Full Text Available Objetivou-se, neste trabalho, estudar a proporção de tecido conjuntivo existente na fração ventricular direita e esquerda do músculo cardíaco de cães, buscando, através da morfometria, dados referentes a inter-relação entre o tecido conjuntivo e o tecido muscular cardíaco, para o conhecimento das relações anátomo-funcionais da estrutura cardíaca, característica de determinados processos ligados a diminuição do trabalho do órgão. Utilizou-se 6 corações de cães SRD, machos e fêmeas, com idade entre 48 e 150 meses, pesando entre 18 e 30 Kg, sem alterações cardíacas, confirmado mediante exames eletrocardiográfico e ecocardiográfico. Preparou-se o material oriundo de três regiões ventriculares em relação a sua base, proximal, média e distal, tanto da face direita quanto da esquerda, segundo as técnicas histológicas convencionais e corados com Picrosirius red, Fucsina-Paraldeido e Tricromo de Gomori, para evidenciação das fibras conjuntivas. As lâminas foram analisadas com auxílio do Axioscópio Zeiss acoplado ao programa de análise de imagens KS-400 Zeiss. A quantidade de tecido conjuntivo no Ventrículo Esquerdo variou de 0,44 a 26,26%; no Ventrículo Direito variou de 0,97 a 21,18%; no ápice variou de 1,32 a 29,24% e no septo interventricular variou de 5,41 a 11,24%. Os resultados obtidos mostram que há uma complexa rede de fibras conjuntivas envolvendo as fibras do tecido muscular cardíaco e que sua quantidade e disposição é muito variada, dependendo da região estudada.

  17. Comparison of retina specialist preferences regarding spectral-domain and swept-source optical coherence tomography angiography

    Directory of Open Access Journals (Sweden)

    Su GL

    2017-05-01

    Full Text Available Grace L Su,1 Douglas M Baughman,2 Qinqin Zhang,3 Kasra Rezaei,2 Aaron Y Lee,2 Cecilia S Lee2 1Lewis Katz School of Medicine, Temple University, Philadelphia, PA, 2Department of Ophthalmology, 3Department of Bioengineering, University of Washington, Seattle, WA, USA Purpose: The aim of this study was to compare physician preferences regarding the commercially available spectral-domain (SD optical coherence tomography angiography (OCTA and swept-source (SS OCTA prototype device.Design: Comparative analysis of diagnostic instruments was performed.Patients and methods: Subjects at the University of Washington Eye Institute and Harborview Medical Center were prospectively recruited and imaged with the Zeiss SD OCTA (HD-5000, Angioplex and Zeiss SS OCTA (Plex Elite, Everest devices on the same day. The study included 10 eyes from 10 subjects diagnosed with a retinal/choroidal disease. Deidentified images were compiled into a survey and sent to retina specialists in various countries. The survey presented masked SD and SS images of each eye for each retinal sublayer side by side. Respondents were asked about their image preference and impact on clinical management. A priori and post hoc preferences for SD vs SS were collected.Results: Fifty-four retina specialists responded to the survey. Median years in practice was 3.00 (interquartile range [IQR] 1.50–17.00. At baseline, 23 (48% physicians owned an OCTA machine. The majority of physician responses showed a preference for the SS over SD OCTA, independent of the retinal pathology shown (n=454 overall responses, 74%. Nevertheless, the majority indicated that both SD and SS would be equally valuable in informing clinical decisions (n=374 overall responses, 61%.Conclusion: These findings indicate that the majority of retina specialists surveyed prefer SS over SD OCTA based on image quality, regardless of the retinal pathology shown. Regarding the clinical utility of each modality, the majority of

  18. Virtual microscopy: an evaluation of its validity and diagnostic performance in routine histologic diagnosis of skin tumors

    DEFF Research Database (Denmark)

    Nielsen, Patricia Switten; Lindebjerg, Jan; Rasmussen, Jan

    2010-01-01

    Digitization of histologic slides is associated with many advantages, and its use in routine diagnosis holds great promise. Nevertheless, few articles evaluate virtual microscopy in routine settings. This study is an evaluation of the validity and diagnostic performance of virtual microscopy...... in routine histologic diagnosis of skin tumors. Our aim is to investigate whether conventional microscopy of skin tumors can be replaced by virtual microscopy. Ninety-six skin tumors and skin-tumor-like changes were consecutively gathered over a 1-week period. Specimens were routinely processed, and digital...... slides were captured on Mirax Scan (Carl Zeiss MicroImaging, Göttingen, Germany). Four pathologists evaluated the 96 virtual slides and the associated 96 conventional slides twice with intermediate time intervals of at least 3 weeks. Virtual slides that caused difficulties were reevaluated to identify...

  19. Digital Levelling in Subterranean Spaces

    Directory of Open Access Journals (Sweden)

    Tomáš Jiřikovský

    2007-06-01

    Full Text Available For precision levelling works are now more often used digital levels and code-scale staffs. Advantages in (and problems with their application to the regular line-levelling are well known and described. However, when using the digital levelling for measurements in specific local geodetic networks, monitoring networks and inside of buildings and underground spaces, new problems appear with the signalisation of the observed points, readability of the code (non-uniform illumination, temperature changes etc. The article informs about the application of two types of digital levels (Sokkia SDL-2, Trimble Zeiss DiNi 12T in the experimental subterranean levelling network for the basement settlement monitoring of a ten-floor building; the solution of marking of the points, field calibration and the system calibration of digital levels.

  20. Investigation of the surface morphology of ion-bombarded biocompatible materials with a SEM and profilograph

    International Nuclear Information System (INIS)

    Kowalski, Z.W.

    1984-01-01

    The surface morphology (topography and roughness) is a very important factor which affects the response of biological tissue to an implant material. The effect of an incident ion beam on surface morphology of various biocompatible materials was studied. All materials were bombarded by Ar + ions at an applied voltage of 7 kV at various incident angles from 0 to 1.4 rad (0 to 80 deg) and at a beam current up to 0.1 mA. The surface topographies of ion-bombarded samples were examined with a Japan Electron Optics Laboratory, model JSM-35, scanning electron microscope. The roughness of the surface was calculated from the shape of a surface profile, which was recorded by a profilograph, the ME 10 (supplied by VEB Carl Zeiss, Jena). (author)

  1. Comparasion of Optic Nerve Head with Stereophotometric and Scanning Laser Ophthalmoscopic Imaging

    Directory of Open Access Journals (Sweden)

    Serek Tekin

    2016-01-01

    Full Text Available Aim: To compare theevaluation results of two experienced clinicians about examination of optic discs in glaucoma patients and healthy inidividuals by stereophotometry and scanning laser ophthalmoscopy. Material and Method: We studied 116 individuals (217 eyes who were divided as normal, glaucoma and suspected glaucoma in numbers of 54, 42 and 20 respectively. Stereophotometric photographs of optic disc were examined with fundus camera (Zeiss, FF 450 plus. Optic disc was also evaluated with HRT-3 in the same visit. Two experienced clinicians evaluated the cup/disc ratios and whether the optic discs were glaucomatous or not. Evaluation results were analysed and compared with HRT-3 examinations. Results:There were no significant age and gende rdifferences between the groups(p>0.05.Stereophotographic C/D ratio correlations between the clinicians were 0.79 (p

  2. Magnetic hysteresis of an artificial square ice studied by in-plane Bragg x-ray resonant magnetic scattering

    Directory of Open Access Journals (Sweden)

    J. P. Morgan

    2012-06-01

    Full Text Available We report X-ray resonant magnetic scattering studies of a Permalloy artificial square ice nanomagnet array, focussing on the field-driven evolution of the sum Σ and difference Δ signals of left and right handed circularly polarized synchrotron X-rays at different lateral positions in reciprocal space Qx. We used X-rays tuned to the Fe L3 resonance energy, with the scattering plane aligned along a principal symmetry axis of the array. Details of the specular Δ hysteresis curve are discussed, following the system magnetization from an initial demagnetized state. The periodic structure gives rise to distinct peaks at in-plane reciprocal Bragg positions, as shown by fitting Σ(Qx to a model based on a simple unit cell structure. Diffraction order-dependent hysteresis in Δ is observed, indicative of the reordering of magnetization on the system's two interpenetrating sublattices, which markedly deviates from an ideal Ising picture under strong applied fields.

  3. Nuclear resonant scattering of synchrotron radiation: Applications in magnetism of layered structures

    International Nuclear Information System (INIS)

    Schlage, Kai; Röhlsberger, Ralf

    2013-01-01

    Highlights: •Depth-resolved determination of magnetic spin structures. •Isotopic probe layers allow for probing selected depths in the sample. •High sensitivity to magnetic domain patterns via diffuse scattering. -- Abstract: Nuclear resonant scattering of synchrotron radiation has become an established tool within condensed-matter research. Synchrotron radiation with its outstanding brilliance, transverse coherence and polarization has opened this field for many unique studies, for fundamental research in the field of light-matter interaction as well as for materials science. This applies in particular for the electronic and magnetic structure of very small sample volumes like micro- and nano-structures and samples under extreme conditions of temperature and pressure. This article is devoted to the application of the technique to nanomagnetic systems such as thin films and multilayers. After a basic introduction into the method, a number of our experiments are presented to illustrate how magnetic spin structures within such layer systems can be revealed

  4. Controlled data storage for non-volatile memory cells embedded in nano magnetic logic

    Science.gov (United States)

    Riente, Fabrizio; Ziemys, Grazvydas; Mattersdorfer, Clemens; Boche, Silke; Turvani, Giovanna; Raberg, Wolfgang; Luber, Sebastian; Breitkreutz-v. Gamm, Stephan

    2017-05-01

    Among the beyond-CMOS technologies, perpendicular Nano Magnetic Logic (pNML) is a promising candidate due to its low power consumption, its non-volatility and its monolithic 3D integrability, which makes it possible to integrate memory and logic into the same device by exploiting the interaction of bi-stable nanomagnets with perpendicular magnetic anisotropy. Logic computation and signal synchronization are achieved by focus ion beam irradiation and by pinning domain walls in magnetic notches. However, in realistic circuits, the information storage and their read-out are crucial issues, often ignored in the exploration of beyond-CMOS devices. In this paper we address these issues by experimentally demonstrating a pNML memory element, whose read and write operations can be controlled by two independent pulsed currents. Our results prove the correct behavior of the proposed structure that enables high density memory embedded in the logic plane of 3D-integrated pNML circuits.

  5. Controlled data storage for non-volatile memory cells embedded in nano magnetic logic

    Directory of Open Access Journals (Sweden)

    Fabrizio Riente

    2017-05-01

    Full Text Available Among the beyond-CMOS technologies, perpendicular Nano Magnetic Logic (pNML is a promising candidate due to its low power consumption, its non-volatility and its monolithic 3D integrability, which makes it possible to integrate memory and logic into the same device by exploiting the interaction of bi-stable nanomagnets with perpendicular magnetic anisotropy. Logic computation and signal synchronization are achieved by focus ion beam irradiation and by pinning domain walls in magnetic notches. However, in realistic circuits, the information storage and their read-out are crucial issues, often ignored in the exploration of beyond-CMOS devices. In this paper we address these issues by experimentally demonstrating a pNML memory element, whose read and write operations can be controlled by two independent pulsed currents. Our results prove the correct behavior of the proposed structure that enables high density memory embedded in the logic plane of 3D-integrated pNML circuits.

  6. Correlation of the Dzyaloshinskii–Moriya interaction with Heisenberg exchange and orbital asphericity

    KAUST Repository

    Kim, Sanghoon

    2018-04-19

    Chiral spin textures of a ferromagnetic layer in contact to a heavy non-magnetic metal, such as Néel-type domain walls and skyrmions, have been studied intensively because of their potential for future nanomagnetic devices. The Dyzaloshinskii–Moriya interaction (DMI) is an essential phenomenon for the formation of such chiral spin textures. In spite of recent theoretical progress aiming at understanding the microscopic origin of the DMI, an experimental investigation unravelling the physics at stake is still required. Here we experimentally demonstrate the close correlation of the DMI with the anisotropy of the orbital magnetic moment and with the magnetic dipole moment of the ferromagnetic metal in addition to Heisenberg exchange. The density functional theory and the tight-binding model calculations reveal that inversion symmetry breaking with spin–orbit coupling gives rise to the orbital-related correlation. Our study provides the experimental connection between the orbital physics and the spin–orbit-related phenomena, such as DMI.

  7. Stochastic Spiking Neural Networks Enabled by Magnetic Tunnel Junctions: From Nontelegraphic to Telegraphic Switching Regimes

    Science.gov (United States)

    Liyanagedera, Chamika M.; Sengupta, Abhronil; Jaiswal, Akhilesh; Roy, Kaushik

    2017-12-01

    Stochastic spiking neural networks based on nanoelectronic spin devices can be a possible pathway to achieving "brainlike" compact and energy-efficient cognitive intelligence. The computational model attempt to exploit the intrinsic device stochasticity of nanoelectronic synaptic or neural components to perform learning or inference. However, there has been limited analysis on the scaling effect of stochastic spin devices and its impact on the operation of such stochastic networks at the system level. This work attempts to explore the design space and analyze the performance of nanomagnet-based stochastic neuromorphic computing architectures for magnets with different barrier heights. We illustrate how the underlying network architecture must be modified to account for the random telegraphic switching behavior displayed by magnets with low barrier heights as they are scaled into the superparamagnetic regime. We perform a device-to-system-level analysis on a deep neural-network architecture for a digit-recognition problem on the MNIST data set.

  8. Structural, Chemical and Physical Properties of Mn12

    Science.gov (United States)

    Sessoli, Roberta

    1997-03-01

    Recent investigations on the physical properties of the first molecular nanomagnet, Mn12ac, will be reported. Among them very high field EPR spectra (up to 25 T) (A. L. Barra, D. Gatteschi, R. Sessoli Phys. Rev. B. submitted) have provided precise information on the spin hamiltonian up to the fourth order terms. These new findings justify the irregularities in the step separations in the quantum hysteresis that we have observed performing the measurements on a single crystal (L. Thomas et al, Nature.383, 145 (1996)), and confirm that we are observing resonant quantum tunneling of the magnetization. The magnetic hysteresis has been also optically detected in collaboration with Prof. A. Thomson of the University of East Anglia, UK. Possible modifications to the Mn12 cluster as well as an iron cluster showing MQT of the magnetization (C. Sangregorio, T. Ohm, C. Paulsen, R. Sessoli, D. Gatteschi, submitted) will be briefly presented.

  9. Amplified Sensitivity of Nitrogen-Vacancy Spins in Nanodiamonds Using All-Optical Charge Readout.

    Science.gov (United States)

    Hopper, David A; Grote, Richard R; Parks, Samuel M; Bassett, Lee C

    2018-04-23

    Nanodiamonds containing nitrogen-vacancy (NV) centers offer a versatile platform for sensing applications spanning from nanomagnetism to in vivo monitoring of cellular processes. In many cases, however, weak optical signals and poor contrast demand long acquisition times that prevent the measurement of environmental dynamics. Here, we demonstrate the ability to perform fast, high-contrast optical measurements of charge distributions in ensembles of NV centers in nanodiamonds and use the technique to improve the spin-readout signal-to-noise ratio through spin-to-charge conversion. A study of 38 nanodiamonds with sizes ranging between 20 and 70 nm, each hosting a small ensemble of NV centers, uncovers complex, multiple time scale dynamics due to radiative and nonradiative ionization and recombination processes. Nonetheless, the NV-containing nanodiamonds universally exhibit charge-dependent photoluminescence contrasts and the potential for enhanced spin readout using spin-to-charge conversion. We use the technique to speed up a T 1 relaxometry measurement by a factor of 5.

  10. Spin switches for compact implementation of neuron and synapse

    Energy Technology Data Exchange (ETDEWEB)

    Quang Diep, Vinh, E-mail: vdiep@purdue.edu; Sutton, Brian; Datta, Supriyo [School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907 (United States); Behin-Aein, Behtash [GLOBALFOUNDRIES, Inc., Sunnyvale, California 94085 (United States)

    2014-06-02

    Nanomagnets driven by spin currents provide a natural implementation for a neuron and a synapse: currents allow convenient summation of multiple inputs, while the magnet provides the threshold function. The objective of this paper is to explore the possibility of a hardware neural network implementation using a spin switch (SS) as its basic building block. SS is a recently proposed device based on established technology with a transistor-like gain and input-output isolation. This allows neural networks to be constructed with purely passive interconnections without intervening clocks or amplifiers. The weights for the neural network are conveniently adjusted through analog voltages that can be stored in a non-volatile manner in an underlying CMOS layer using a floating gate low dropout voltage regulator. The operation of a multi-layer SS neural network designed for character recognition is demonstrated using a standard simulation model based on coupled Landau-Lifshitz-Gilbert equations, one for each magnet in the network.

  11. NMR-MRI, μSR and Mössbauer Spectroscopies in Molecular Magnets

    CERN Document Server

    Carretta, Pietro

    2007-01-01

    The discovery of molecular nanomagnets showing novel quantum effects, as the quantum tunneling of the magnetization, has brought to a renewed interest for the study of molecular magnetism and multifunctional molecular material. These materials have recently triggered an intense research activity in view of their possible applicabilities as, for example, as nanosized information storage units and as magnetic nanoparticles for bio-medicine. Several fundamental aspects of the microscopic static and dynamic properties of these molecular materials have been obtained by means of spectroscopies using local probes, as nuclei and muons. In this book an extensive overview on the results obtained during the last decade and on recent achievements in the study of molecular magnets by means of Nuclear Magnetic Resonance, Muon Spin Rotation, Magnetic Resonance Imaging and Mossbauer techniques is presented. The aim is to introduce the reader to these techniques and to give a general background on their application to molecul...

  12. Development of 40m SANS and Its Utilization Techniques

    International Nuclear Information System (INIS)

    Choi, Sung Min; Kim, Tae Hwan

    2010-06-01

    Small angle neutron scattering (SANS) has been a very powerful tool to study nanoscale (1-100 nm) bulk structures in various materials such as polymer, self assembled materials, nano-porous materials, nano-magnetic materials, metal and ceramics. Understanding the importance of the SANS instrument, the 8m SANS instrument was installed at the CN beam port of HANARO in 2001. However, without having a cold neutron source, the beam intensity is fairly low and the Q-range is rather limited due to short instrument length. In July 1, 2003, therefore, the HANARO cold neutron research facility project was launched and a state of the art 40m SANS instrument was selected as top-priority instrument. The development of the 40m SANS instrument was completed as a joint project between Korea Advanced Institute of Science and Technology and the HANARO in 2010. Here, we report the specification of a state of art 40m SANS instrument at HANARO

  13. Spin switches for compact implementation of neuron and synapse

    International Nuclear Information System (INIS)

    Quang Diep, Vinh; Sutton, Brian; Datta, Supriyo; Behin-Aein, Behtash

    2014-01-01

    Nanomagnets driven by spin currents provide a natural implementation for a neuron and a synapse: currents allow convenient summation of multiple inputs, while the magnet provides the threshold function. The objective of this paper is to explore the possibility of a hardware neural network implementation using a spin switch (SS) as its basic building block. SS is a recently proposed device based on established technology with a transistor-like gain and input-output isolation. This allows neural networks to be constructed with purely passive interconnections without intervening clocks or amplifiers. The weights for the neural network are conveniently adjusted through analog voltages that can be stored in a non-volatile manner in an underlying CMOS layer using a floating gate low dropout voltage regulator. The operation of a multi-layer SS neural network designed for character recognition is demonstrated using a standard simulation model based on coupled Landau-Lifshitz-Gilbert equations, one for each magnet in the network

  14. NANOBIOCATALYTIC SYSTEMS BASED ON LIPASE-Fe3O4 AND CONVENTIONAL SYSTEMS FOR ISONIAZID SYNTHESIS: A COMPARATIVE STUDY

    Directory of Open Access Journals (Sweden)

    V. M. Costa

    Full Text Available Abstract Superparamagnetic nanomaterials have attracted interest in many areas due to the high saturation magnetization and surface area. For enzyme immobilization, these properties favor the enzyme-support contact during the immobilization reaction and easy separation from the reaction mixture by use of low-cost magnetic processes. Iron oxide magnetic nanoparticles (Fe3O4, MNPs, produced by the co-precipitation method, functionalized with 3-aminopropyltriethoxysilane (APTES and glutaraldehyde (GLU, were evaluated as a solid support for Candida antarctica lipase B (CALB immobilization. The nanomagnetic derivative (11nm obtained after CALB immobilization (MNPs/APTES/GLU/CALB was evaluated as biocatalyst in isoniazide (INH synthesis using ethyl isonicotinate (INE and hydrazine hydrate (HID as substrates, in 1,4-dioxane. The results showed that MNPs/APTES/CALB had a similar performance when compared to a commercial enzyme Novozym 435, showing significant advantages over other biocatalysts, such as Rhizhomucor miehei lipase (RML and CALB immobilized on non-conventional, low-cost, chitosan-based supports.

  15. Nanoscale magnetic ratchets based on shape anisotropy

    Science.gov (United States)

    Cui, Jizhai; Keller, Scott M.; Liang, Cheng-Yen; Carman, Gregory P.; Lynch, Christopher S.

    2017-02-01

    Controlling magnetization using piezoelectric strain through the magnetoelectric effect offers several orders of magnitude reduction in energy consumption for spintronic applications. However strain is a uniaxial effect and, unlike directional magnetic field or spin-polarized current, cannot induce a full 180° reorientation of the magnetization vector when acting alone. We have engineered novel ‘peanut’ and ‘cat-eye’ shaped nanomagnets on piezoelectric substrates that undergo repeated deterministic 180° magnetization rotations in response to individual electric-field-induced strain pulses by breaking the uniaxial symmetry using shape anisotropy. This behavior can be likened to a magnetic ratchet, advancing magnetization clockwise with each piezostrain trigger. The results were validated using micromagnetics implemented in a multiphysics finite elements code to simulate the engineered spatial and temporal magnetic behavior. The engineering principles start from a target device function and proceed to the identification of shapes that produce the desired function. This approach opens a broad design space for next generation magnetoelectric spintronic devices.

  16. Spin Dynamics and Quantum Tunneling in Fe8 Nanomagnet and in AFM Rings by NMR

    Energy Technology Data Exchange (ETDEWEB)

    Ho-Baek, Seung [Iowa State Univ., Ames, IA (United States)

    2004-01-01

    In this thesis, our main interest has been to investigate the spin dynamics and quantum tunneling in single molecule magnets (SMMs), For this we have selected two different classes of SMMs: a ferrimagnetic total high spin S = 10 cluster Fe8 and antiferromagnetic (AFM) ring-type clusters. For Fe8, our efforts have been devoted to the investigation of the quantum tunneling of magnetization in the very low temperature region. The most remarkable experimental finding in Fe8 is that the nuclear spin-lattice relaxation rate (1/T{sub l}) at low temperatures takes place via strong collision mechanism, and thus it allows to measure directly the tunneling rate vs T and H for the first time. For AFM rings, we have shown that 1/T{sub l} probes the thermal fluctuations of the magnetization in the intermediate temperature range. We find that the fluctuations are dominated by a single characteristic frequency which has a power law T-dependence indicative of fluctuations due to electron-acoustic phonon interactions.

  17. Spin dynamics and quantum tunneling in Fe8 nanomagnet and in AFM rings by NMR

    Science.gov (United States)

    Baek, Seung-Ho

    In this thesis, our main interest has been to investigate the spin dynamics and quantum tunneling in single molecule magnets (SMMs). For this we have selected two different classes of SMMs: a ferromagnetic total high spin S = 10 cluster Fe8 and antiferromagnetic (AFM) ring-type clusters. For Fe8, our efforts have been devoted to the investigation of the quantum tunneling of magnetization in the very low temperature region. The most remarkable experimental finding in Fe8 is that the nuclear spin-lattice relaxation rate (1/T1) at low temperatures takes place via strong collision mechanism, and thus it allows to measure directly the tunneling rate vs. T and H for the first time. For AFM rings, we have shown that 1/T1 probes the thermal fluctuations of the magnetization in the intermediate temperature range. We find that the fluctuations are dominated by a single characteristic frequency which has a power-law T-dependence indicative of fluctuations due to electron-acoustic phonon interactions.

  18. Spin Dynamics and Quantum Tunneling in Fe8 Nanomagnet and in AFM Rings by NMR

    International Nuclear Information System (INIS)

    Seung-Ho-Baek

    2004-01-01

    In this thesis, our main interest has been to investigate the spin dynamics and quantum tunneling in single molecule magnets (SMMs), For this we have selected two different classes of SMMs: a ferrimagnetic total high spin S = 10 cluster Fe8 and antiferromagnetic (AFM) ring-type clusters. For Fe8, our efforts have been devoted to the investigation of the quantum tunneling of magnetization in the very low temperature region. The most remarkable experimental finding in Fe8 is that the nuclear spin-lattice relaxation rate (1/T l ) at low temperatures takes place via strong collision mechanism, and thus it allows to measure directly the tunneling rate vs T and H for the first time. For AFM rings, we have shown that 1/T l probes the thermal fluctuations of the magnetization in the intermediate temperature range. We find that the fluctuations are dominated by a single characteristic frequency which has a power law T-dependence indicative of fluctuations due to electron-acoustic phonon interactions

  19. Nanoelectronics, Nanophotonics, and Nanomagnetics: Report of the National Nanotechnology Initiative Workshop February 11-13, 2004

    Science.gov (United States)

    2004-02-01

    of Intel. Magnetic cobalt nanoparticles self-assembled into bracelet-like “ nanorings ,” courtesy of Alexander Wei and Purdue University News Service...corrugation. The concentric ring pattern was milled into a sapphire substrate, which was then overcoated with 300 nm of silver . As a final step, a...Malicka, I. Gryczynski, Z. Gryczynski, J. R. Lakowicz, Effects of fluorophore-to- silver distance on the emission of cyanine-dye-labeled

  20. Circuit Simulation of All-Spin Logic

    KAUST Repository

    Alawein, Meshal

    2016-05-01

    With the aggressive scaling of complementary metal-oxide semiconductor (CMOS) nearing an inevitable physical limit and its well-known power crisis, the quest for an alternative/augmenting technology that surpasses the current semiconductor electronics is needed for further technological progress. Spintronic devices emerge as prime candidates for Beyond CMOS era by utilizing the electron spin as an extra degree of freedom to decrease the power consumption and overcome the velocity limit connected with the charge. By using the nonvolatility nature of magnetization along with its direction to represent a bit of information and then manipulating it by spin-polarized currents, routes are opened for combined memory and logic. This would not have been possible without the recent discoveries in the physics of nanomagnetism such as spin-transfer torque (STT) whereby a spin-polarized current can excite magnetization dynamics through the transfer of spin angular momentum. STT have expanded the available means of switching the magnetization of magnetic layers beyond old classical techniques, promising to fulfill the need for a new generation of dense, fast, and nonvolatile logic and storage devices. All-spin logic (ASL) is among the most promising spintronic logic switches due to its low power consumption, logic-in-memory structure, and operation on pure spin currents. The device is based on a lateral nonlocal spin valve and STT switching. It utilizes two nanomagnets (whereby information is stored) that communicate with pure spin currents through a spin-coherent nonmagnetic channel. By using the well-known spin physics and the recently proposed four-component spin circuit formalism, ASL can be thoroughly studied and simulated. Previous attempts to model ASL in the linear and diffusive regime either neglect the dynamic characteristics of transport or do not provide a scalable and robust platform for full micromagnetic simulations and inclusion of other effects like spin Hall

  1. Application of differential interference contrast with inverted microscopes to the in vitro perfused nephron.

    Science.gov (United States)

    Horster, M; Gundlach, H

    1979-12-01

    The study of in vitro perfused individual nephron segments requires a microscope which provides: (1) easy access to the specimen for measurement of cellular solute flux and voltage; (2) an image with high resolution and contrast; (3) optical sectioning of the object at different levels; and (4) rapid recording of the morphological phenomena. This paper describes an example of commercially available apparatus meeting the above requirements, and illustrates its efficiency. The microscope is of the inverted type (Zeiss IM 35) equipped with differential-interference-contrast (DIC) with a long working distance, and an automatically controlled camera system. The microscopic image exhibits cellular and intercellular details in the unstained transporting mammalian nephron segments despite their tubular structure and great thickness and makes obvious function-structure correlations (e.g. cell volume changes); luminal and contraluminal cell borders are well resolved for controlled microelectrode impalement.

  2. Photogrammetry experiments with a model eye.

    Science.gov (United States)

    Rosenthal, A R; Falconer, D G; Pieper, I

    1980-01-01

    Digital photogrammetry was performed on stereophotographs of the optic nerve head of a modified Zeiss model eye in which optic cups of varying depths could be simulated. Experiments were undertaken to determine the impact of both photographic and ocular variables on the photogrammetric measurements of cup depth. The photogrammetric procedure tolerates refocusing, repositioning, and realignment as well as small variations in the geometric position of the camera. Progressive underestimation of cup depth was observed with increasing myopia, while progressive overestimation was noted with increasing hyperopia. High cylindrical errors at axis 90 degrees led to significant errors in cup depth estimates, while high cylindrical errors at axis 180 degrees did not materially affect the accuracy of the analysis. Finally, cup depths were seriously underestimated when the pupil diameter was less than 5.0 mm. Images PMID:7448139

  3. Seven year follow-up after advanced surface ablation with excimer laser for treatment of myopia: Long-term outcomes of cooling PRK and LASEK

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    Purpose: To evaluate and compare refractive predictability, uncorrected and corrected distance visual acuity (UDVA and CDVA), corneal haze, corneal densitometry and patient satisfaction up to 7 years after Photorefractive Keratectomy with cooling (cPRK) and Laser-Assisted Sub-epithelial Keratectomy...... (LASEK) for all degrees of myopia, but in particular high myopia. Setting: Department of Ophthalmology, Odense University Hospital, Odense, Denmark. Methods: Retrospective follow-up study of eyes treated with cPRK or LASEK for all degrees of myopia from 2007 to 2009 at the Department of Ophthalmology...... laser with eye-tracker (Carl Zeiss Meditec AG, Jena, Germany) was used for photoablation in both procedures. Optical zone size ranged from 5.50 to 6.00 mm in both procedures, and maximum attempted spherical correction was -8.50 D. cPRK was performed as a standard PRK procedure, but with immediately...

  4. Approach for investigations of progressive fatigue damage in 3D in fibre composites using X-ray tomography

    DEFF Research Database (Denmark)

    Mikkelsen, Lars Pilgaard; Jespersen, Kristine Munk

    (Jespersen & Mikkelsen, 2016) has been performed. An ex-situ study where it has been important to design a good gripping strategy inside the scanning machine. Doing this, it has been possible to scan the same region multiple times. Thereby, a progressive fatigue damage evolution has been observed.......Understanding fatigue damage initiation and evolution in the load carrying laminates inside wind turbine blade plays a key factor designing longer and lighter turbine blades. Thereby, it is possible to lower the Cost of Energy for the wind energy based electricity production either by simply...... building larger wind turbines or by upgrading existing turbines for lower wind classes’ . In the presented work, a Zeiss Xradia Versa 520 scanner has been used in connection with ex-situ fatigue testing with the purpose of identifying fibre failure during the fatigue loading. The load carrying laminates...

  5. Measuring large aspherics using a commercially available 3D-coordinate measuring machine

    Science.gov (United States)

    Otto, Wolfgang; Matthes, Axel; Schiehle, Heinz

    2000-07-01

    A CNC-controlled precision measuring machine is a very powerful tool in the optical shop not only to determine the surface figure, but also to qualify the radius of curvature and conic constant of aspherics. We used a commercially available 3D-coordinate measuring machine (CMM, ZEISS UPMC 850 CARAT S-ACC) to measure the shape of the GEMINI 1-m convex secondary mirrors at different lapping and polishing stages. To determine the measuring accuracy we compared the mechanical measurements with the results achieved by means of an interferometrical test setup. The data obtained in an early stage of polishing were evaluated in Zernike polynomials which show a very good agreement. The deviation concerning long wave rotational symmetrical errors was 20 nm rms, whereas the accuracy measuring of mid spatial frequency deviations was limited to about 100 nm rms.

  6. A possible early sign of hydroxychloroquine macular toxicity.

    Science.gov (United States)

    Brandao, Livia M; Palmowski-Wolfe, Anja M

    2016-02-01

    Hydroxychloroquine (HCQ) has a low risk of retinal toxicity which increases dramatically with a cumulative dose of >1000 g. Here we report a case of HCQ macular toxicity presentation in a young patient with a cumulative dose of 438 g. A 15-year-old female started attending annual consultations for retinal toxicity screening in our clinic after 3 years of HCQ treatment for juvenile idiopathic dermatomyositis. She had been diagnosed at age 12 and had been on hydroxychloroquine 200 mg/day, cyclosporin 150 mg/day and vitamin D3 since. Screening consultations included: complete ophthalmologic examination, automated perimetry (AP, M Standard, Octopus 101, Haag-Streit), multifocal electroretinogram (VERIS 6.06™, FMSIII), optical coherence tomography (OCT, fast macular protocol, Cirrus SD-OCT, Carl Zeiss), fundus autofluorescence imaging (Spectralis OCT, Heidelberg Engineering Inc.) and color testing (Farnsworth-Panel-D-15). After 5 years of treatment, AP demonstrated reduced sensibility in only one extra-foveal point in each eye (p < 0.2). Even though other exams showed no alteration and the cumulative dose was only around 353 g, consultations were increased to every 6 months. After 2-year follow-up, that is, 7 years of HCQ, a bilateral paracentral macula thinning was evident on OCT, suggestive of bull's eye maculopathy. However, the retinal pigmented epithelium appeared intact and AP was completely normal in both eyes. Further evaluation with ganglion cell analysis (GCA = ganglion cell + inner plexiform layer, Cirrus SD-OCT, Carl Zeiss) showed a concentric thinning of this layer in the same area. Although daily and cumulative doses were still under the high toxicity risk parameters, HCQ was suspended. At a follow-up 1 year later, visual acuity was 20/16 without any further changes in OCT or on any other exam. This may be the first case report of insidious bull's eye maculopathy exclusively identified using OCT thickness analysis, in a patient in whom both cumulative

  7. Wilhelm Winkler (1842-1910) - a Thuringian private astronomer and maecenas

    Science.gov (United States)

    Weise, Wilfried; Dorschner, Johann; Schielicke, Reinhardt E.

    Wilhelm Winkler was born in 1842 in Eisenberg, Thuringia, as the son of a lawyer. After attending the trading high school in Gera, Winkler worked as a merchant in Eisenberg, following in the footsteps of his grandfather. In 1875 he gave up this trade and devoted his time entirely to astronomy. Advised by Carl Bruhns, director of the Leipzig University Observatory, he established an observatory on his estate in Gohlis near Leipzig. From 1878 Winkler regularly observed sunspots; other fields of his observational interests were comets, occultations of stars by the Moon, and Jupiter's satellites. In 1887 he went to Jena, where he contacted Ernst Abbe, who was the head of the Jena observatory, too. For some years, Winkler's instruments were used in the new observatory erected by Abbe, which replaced the old Ducal Observatory of the Goethe era. Winkler donated the precision pendulum clock and some other instruments to this observatory. He also offered his observational assistance whenever it was wanted. In 1893 Winkler built up his own observatory in Jena and published annual reports on his work in the Vierteljahrsschrift of the Astronomische Gesellschaft. His observational results mainly appeared in the journal Astronomische Nachrichten. In 1902 he was awarded an honorary doctor's degree by the Philosophical Faculty of Jena University. However, at that time his physical constitution began gradually to fade. He lost his left eye due to a sarcoma, and finally he died at the age of 68. In his will, he left 100 000 Mark in form of securities to Jena University (Winkler Foundation). The University Observatory got his 4.5 m dome, the transport of which from his residence to the final site was also paid for by him, several instruments, and a lot of books. In 1936 Winkler's dome was closed by the University. The observatory was transferred from the University to the Zeiss works in exchange for the observatory in the Jena Forst. Zeiss sponsored the reconstruction of the old dome

  8. Clinical Prediction Performance of Glaucoma Progression Using a 2-Dimensional Continuous-Time Hidden Markov Model with Structural and Functional Measurements.

    Science.gov (United States)

    Song, Youngseok; Ishikawa, Hiroshi; Wu, Mengfei; Liu, Yu-Ying; Lucy, Katie A; Lavinsky, Fabio; Liu, Mengling; Wollstein, Gadi; Schuman, Joel S

    2018-03-20

    Previously, we introduced a state-based 2-dimensional continuous-time hidden Markov model (2D CT HMM) to model the pattern of detected glaucoma changes using structural and functional information simultaneously. The purpose of this study was to evaluate the detected glaucoma change prediction performance of the model in a real clinical setting using a retrospective longitudinal dataset. Longitudinal, retrospective study. One hundred thirty-four eyes from 134 participants diagnosed with glaucoma or as glaucoma suspects (average follow-up, 4.4±1.2 years; average number of visits, 7.1±1.8). A 2D CT HMM model was trained using OCT (Cirrus HD-OCT; Zeiss, Dublin, CA) average circumpapillary retinal nerve fiber layer (cRNFL) thickness and visual field index (VFI) or mean deviation (MD; Humphrey Field Analyzer; Zeiss). The model was trained using a subset of the data (107 of 134 eyes [80%]) including all visits except for the last visit, which was used to test the prediction performance (training set). Additionally, the remaining 27 eyes were used for secondary performance testing as an independent group (validation set). The 2D CT HMM predicts 1 of 4 possible detected state changes based on 1 input state. Prediction accuracy was assessed as the percentage of correct prediction against the patient's actual recorded state. In addition, deviations of the predicted long-term detected change paths from the actual detected change paths were measured. Baseline mean ± standard deviation age was 61.9±11.4 years, VFI was 90.7±17.4, MD was -3.50±6.04 dB, and cRNFL thickness was 74.9±12.2 μm. The accuracy of detected glaucoma change prediction using the training set was comparable with the validation set (57.0% and 68.0%, respectively). Prediction deviation from the actual detected change path showed stability throughout patient follow-up. The 2D CT HMM demonstrated promising prediction performance in detecting glaucoma change performance in a simulated clinical setting

  9. Outcomes for Myopic LASIK With the MEL 90 excimer laser.

    Science.gov (United States)

    Reinstein, Dan Z; Carp, Glenn I; Lewis, Tariq A; Archer, Timothy J; Gobbe, Marine

    2015-05-01

    To evaluate the visual outcomes of myopic LASIK performed with the MEL 90 excimer laser (Carl Zeiss Meditec AG, Jena, Germany) using the Triple-A profile with a 500-Hz pulse rate. Retrospective analysis of the first 286 myopic LASIK procedures (147 patients) by two experienced surgeons in which the VisuMax femtosecond laser and MEL 90 excimer laser (Carl Zeiss Meditec) were used following a standardized surgical technique. Inclusion criteria were preoperative spherical equivalent refraction (SEQ) up to -10.38 diopters (D), cylinder up to 5.00 D, and corrected distance visual acuity (CDVA) of 20/25 or better. No nomogram adjustments were made. Patients were observed for 3 months. Flap thickness was between 80 and 110 µm and optical zone was between 6 and 7 mm. Standard outcomes analysis was performed. Preoperatively, mean SEQ was -3.83 ± 1.83 D (range: -0.13 to -10.38 D) and mean cylinder was -0.94 ± 0.86 D (range: 0.00 to -5.00 D). Mean age was 36.4 years (range: 18.2 to 74.1 years) with 50% female patients. Of this population, 138 eyes were treated by one surgeon and 148 eyes by another. The mean predictability of SEQ was -0.13 ± 0.34 D (range: -1.00 to +1.00 D). Postoperative SEQ was ± 0.50 D in 88% and ± 1.00 D in 100% of eyes. Preoperative CDVA was 20/20 or better in 97% of eyes. Postoperative uncorrected distance visual acuity was 20/20 or better in 92% and 20/25 or better in 99% of eyes. One line of CDVA was lost in 6% of eyes and no eyes lost two or more lines. There was statistically significant improvement in mesopic contrast sensitivity (CSV-1000) at 3 (P = .021), 6, 12, and 18 (all P ≤.001) cycles per degree. The MEL 90 excimer laser using the Triple-A ablation profile with a 500-Hz pulse rate was found to achieve a small but real increase in contrast sensitivity and high efficacy for myopia up to -10.00 D and cylinder up to 5.00 D without the need for a nomogram adjustment. Copyright 2015, SLACK Incorporated.

  10. Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage

    DEFF Research Database (Denmark)

    Zheng, Yi; Yang, Yan; Rogowska, M.

    2017-01-01

    to achieve this is to find a suitable condition to create a stable 3D space in carbonate rock by injecting liquid to prepare space for the later CO2 injection. Micro-CT imaging is a non-destructive 3D method that can be used to study the property changes of carbonate rocks during and after CO2 injection....... The advance in lab source based micro-CT has made it capable of in situ experiments. We used a commercial bench top micro-CT (Zeiss Versa XRM410) to study the microstructure changes of chalk during liquid injection. Flexible temporal CT resolution is essential in this study because that the time scales...... of coupled physical and chemical processes can be very different. The results validated the feasibility of using a bench top CT system with a pressure cell to monitor the mesoscale multiphase interactions in chalk....

  11. Thermodynamics of small systems by nanocalorimetry: From physical to biological nano-objects

    International Nuclear Information System (INIS)

    Garden, J.-L.; Guillou, H.; Lopeandia, A.F.; Richard, J.; Heron, J.-S.; Souche, G.M.; Ong, F.R.; Vianay, B.; Bourgeois, O.

    2009-01-01

    Membrane based nanocalorimeters have been developed for ac-calorimetry experiments. It has allowed highly sensitive measurements of heat capacity from solid state physics to complex systems like polymers and proteins. In this article we review what has been developed in ac-calorimetry toward the measurement of very small systems. Firstly, at low temperature ac-calorimetry using silicon membrane permits the measurement of superconducting sample having geometry down to the nanometer scale. New phase transitions have been found in these nanosystems illustrated by heat capacity jumps versus the applied magnetic field. Secondly, a sensor based on ultra-thin polymer membrane will be presented. It has been devoted to thermal measurements of nanomagnetic systems at intermediate temperature (20-300 K). Thirdly, three specific polyimide membrane based sensors have been designed for room temperature measurements. One is devoted to phase transitions detection in polymer, the second one to protein folding/unfolding studies and the third one will be used for the study of heat release in living cells. The possibility of measuring systems out of equilibrium will be emphasized.

  12. The synthesis of Cu/Fe/Fe3O4 catalyst through the aqueous solution ball milling method assisted by high-frequency electromagnetic field

    Science.gov (United States)

    Yingzhe, Zhang; Yuxing, He; Qingdong, Qin; Fuchun, Wang; Wankun, Wang; Yongmei, Luo

    2018-06-01

    In this paper, nano-magnetic Cu/Fe/Fe3O4 catalyst was prepared by a new aqueous solution ball milling method assisted by high-frequency electromagnetic field at room temperature. The products were characterized by means of X-ray diffraction (XRD), high-resolution transmission electron microscope (HRTEM), selected area electron diffraction (SAED), and vibrating sample magnetometer (VSM). Microwave induced catalytic degradation of methylene blue (MB) was carried out in the presence of Cu/Fe/Fe3O4. The concentration of methylene blue was determined by UV-Vis spectrophotometry. The solid catalyst showed high catalytic activity of degrade MB and considerable saturation magnetization, lower remanence and coercivity. It indicate that the catalyst can be effectively separated for reuse by simply applying an external magnetic field and it can greatly promote their potential industrial application to eliminate organic pollutants from waste-water. Finally, we found that it is the non-thermal effect of microwave that activated the catalytic activity of Cu/Fe/Fe3O4 to degrade MB.

  13. Scaling Projections on Spin-Transfer Torque Magnetic Tunnel Junctions

    Science.gov (United States)

    Das, Debasis; Tulapurkar, Ashwin; Muralidharan, Bhaskaran

    2018-02-01

    We investigate scaling of technologically relevant magnetic tunnel junction devices in the trilayer and pentalayer configurations by varying the cross-sectional area along the transverse direction using the non-equilibrium Green's function spin transport formalism. We study the geometry dependence by considering square and circular cross-sections. As the transverse dimension in each case reduces, we demonstrate that the transverse mode energy profile plays a major role in the resistance-area product. Both types of devices show constant tunnel magnetoresistance at larger cross-sectional areas but achieve ultra-high magnetoresistance at small cross-sectional areas, while maintaining low resistance-area products. We notice that although the critical switching voltage for switching the magnetization of the free layer nanomagnet in the trilayer case remains constant at larger areas, it needs more energy to switch at smaller areas. In the pentalayer case, we observe an oscillatory behavior at smaller areas as a result of double barrier tunneling. We also describe how switching characteristics of both kinds of devices are affected by the scaling.

  14. Multi-frequency EPR studies of a mononuclear holmium single-molecule magnet based on the polyoxometalate [Ho(III)(W5O18)2]9-.

    Science.gov (United States)

    Ghosh, Sanhita; Datta, Saiti; Friend, Lisa; Cardona-Serra, Salvador; Gaita-Ariño, Alejandro; Coronado, Eugenio; Hill, Stephen

    2012-11-28

    Continuous-wave, multi-frequency electron paramagnetic resonance (EPR) studies are reported for a series of single-crystal and powder samples containing different dilutions of a recently discovered mononuclear Ho(III) (4f(10)) single-molecule magnet (SMM) encapsulated in a highly symmetric polyoxometalate (POM) cage. The encapsulation offers the potential for applications in molecular spintronics devices, as it preserves the intrinsic properties of the nanomagnet outside of the crystal. A significant magnetic anisotropy arises due to a splitting of the Hund's coupled total angular momentum (J = L + S = 8) ground state in the POM ligand field. Thus, high-frequency (50.4 GHz) EPR studies reveal a highly anisotropic eight line spectrum corresponding to transitions within the lowest m(J) = ±4 doublet, split by a strong hyperfine interaction with the I = 7/2 Ho nucleus (100% natural abundance). X-band EPR studies reveal the presence of an appreciable tunneling gap between the m(J) = ±4 doublet states having the same nuclear spin projection, leading to a highly non-linear field-dependence of the spectrum at low-frequencies.

  15. Fe3O4/PS magnetic nanoparticles: Synthesis, characterization and their application as sorbents of oil from waste water

    Science.gov (United States)

    Yu, Liuhua; Hao, Gazi; Gu, Junjun; Zhou, Shuai; Zhang, Ning; Jiang, Wei

    2015-11-01

    In this work, Fe3O4/PS composites with a rough surface and different coating rates were successfully designed and synthesized by emulsion polymerization. We carried out some comparative experiments to compare magnetic properties and oil absorption properties of the nano-magnetic materials. It had been found that several prepared groups of magnetic nanocomposites have a core-shell structure and good coating rates. These nanoparticles combined with unsinked, highly hydrophobic and superoleophilic properties. The absorption capacity of Fe3O4/PS composites for organic solvents and the composites could absorb diesel oil up to 2.492 times of its own weight. It is more important that the oil could be readily removed from the surfaces of nanoparticles by a simple ultrasonic treatment whereas the nanocomposites particles still kept highly hydrophobic and superoleophilic characteristics. With a combination of simple synthesis process, low density, magnetic responsibility and excellent hydrophobicity, Fe3O4/PS nanocomposites as a promising absorbent have great potential in the application of spilled oil recovery and environmental protection.

  16. A phenomenological approach to study the effect of uniaxial anisotropy on the magnetization of ferromagnetic nanoparticles

    Science.gov (United States)

    Sánchez-Marín, N.; Cuchillo, A.; Knobel, M.; Vargas, P.

    2018-04-01

    We study the effect of the uniaxial anisotropy in a system of ideal, noninteracting ferromagnetic nanoparticles by means of a thermodynamical model. We show that the effect of the anisotropy can be easily assimilated in a temperature shift Ta∗, in analogy to what was proposed by Allia et al. (2001) in the case of interacting nanomagnets. The phenomenological anisotropic Ta∗ parameter can be negative, indicating an antiferromagnetic-like behavior, or positive, indicating a ferromagnetic-like character as seen in the inverse susceptibility behavior as a function of temperature. The study is done considering an easy axis distribution to take into account the anisotropy axis dispersion in real samples (texture). In the case of a volumetric uniform distribution of anisotropy axes, the net effect makes Ta∗ to vanish, and the magnetic susceptibility behaves like a conventional superparamagnetic system, whereas in the others a finite value is obtained for Ta∗ . When magnetic moment distribution is considered, the effect is to enhance the Ta∗ parameter, when the dispersion of the magnetic moments becomes wider.

  17. Tailor-made nano-structured materials for perpendicular recording media and head-precise control of direct/indirect exchange coupling

    International Nuclear Information System (INIS)

    Takahashi, Migaku; Tsunoda, Masakiyo; Saito, Shin

    2009-01-01

    Tailor-made nano-structured spin materials obtained by precisely controlled nano-scale fabrication technologies for use in ultra-high density hard disk drives (HDDs), as well as an understanding of their nanomagnetics, are essential from the view point of materials, processes, and physics. Artificial control of the exchange coupling among ferromagnetic layers through the RKKY interaction (indirect) and direct exchange coupling represented as the exchange bias at the ferromagnetic (FM)/antiferromagnetic (AFM) interface are of great interest and have received significant attention to induce new modulated spin structures in conventional simple FM materials. In particular, soft magnetic under layer (SUL) with strong synthetic antiferromagnetic (SAF) coupling between two adjacent soft magnetic layers, exchange coupled stacked media introducing exchange coupling between FM layers and giant exchange anisotropy at the FM/AFM interface have attracted significant attention from the view point of applications. Within the framework of the present paper, we discuss future technical trends for SUL, granular media and the spin-valve head from the viewpoint of direct and/or indirect exchange coupling based on our recent results

  18. Vortex formation in narrow ferromagnetic rings

    International Nuclear Information System (INIS)

    Klaeui, M; Vaz, C A F; Lopez-Diaz, L; Bland, J A C

    2003-01-01

    The high-symmetry ring geometry is shown to exhibit a wide range of intriguing magnetostatic and magnetodynamic properties, which we survey in this topical review. We consider first the patterning and deposition techniques, which are used to fabricate ring structures (diameters between 0.1 and 2 μm) and discuss their respective advantages and disadvantages. The results of direct nanoscale imaging of the novel magnetization configurations present in rings with different geometrical parameters (including discs) are discussed. These results give valuable insight into the influence of the magnetic anisotropies governing the magnetic states. The different types of domain walls that arise are compared quantitatively to micromagnetic simulations. The magnetodynamic switching between the different magnetic states is described in detail. In particular we elaborate on the different geometry-dependent magnetic switchings, since the different transitions occurring allow us to determine which energy terms govern the reversal process. We discuss a process by which fast (sub-ns) and controlled switching can be achieved, therefore making rings an attractive geometry for applications, in addition to studying fundamental issues of nanomagnetism. (topical review)

  19. Magnetization reversal in magnetic dot arrays: Nearest-neighbor interactions and global configurational anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Van de Wiele, Ben [Department of Electrical Energy, Systems and Automation, Ghent University, Technologiepark 913, B-9052 Ghent-Zwijnaarde (Belgium); Fin, Samuele [Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, 44122 Ferrara (Italy); Pancaldi, Matteo [CIC nanoGUNE, E-20018 Donostia-San Sebastian (Spain); Vavassori, Paolo [CIC nanoGUNE, E-20018 Donostia-San Sebastian (Spain); IKERBASQUE, Basque Foundation for Science, E-48013 Bilbao (Spain); Sarella, Anandakumar [Physics Department, Mount Holyoke College, 211 Kendade, 50 College St., South Hadley, Massachusetts 01075 (United States); Bisero, Diego [Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, 44122 Ferrara (Italy); CNISM, Unità di Ferrara, 44122 Ferrara (Italy)

    2016-05-28

    Various proposals for future magnetic memories, data processing devices, and sensors rely on a precise control of the magnetization ground state and magnetization reversal process in periodically patterned media. In finite dot arrays, such control is hampered by the magnetostatic interactions between the nanomagnets, leading to the non-uniform magnetization state distributions throughout the sample while reversing. In this paper, we evidence how during reversal typical geometric arrangements of dots in an identical magnetization state appear that originate in the dominance of either Global Configurational Anisotropy or Nearest-Neighbor Magnetostatic interactions, which depends on the fields at which the magnetization reversal sets in. Based on our findings, we propose design rules to obtain the uniform magnetization state distributions throughout the array, and also suggest future research directions to achieve non-uniform state distributions of interest, e.g., when aiming at guiding spin wave edge-modes through dot arrays. Our insights are based on the Magneto-Optical Kerr Effect and Magnetic Force Microscopy measurements as well as the extensive micromagnetic simulations.

  20. Biological Derived Nanomotors in a ``Domino Fashion''

    Science.gov (United States)

    Maksoed, W. H.

    2015-11-01

    For disproportionation of H2 O2 , we also considers an electrokinetic mechanism they appear.So far, the more efficient micro/nanoscale motors are derived from biological systems [2003]. Besides, a control experimenting using 3 stripped Au/Pt/Au rods with catalyzed the composition of H2 O2 , at a similar rate-Walter F Paxton: ``Catalytic Nanomotors,'' JACS, 2004. We also intended to accomaplishes the HCCI quotes from Marcin Frackowiak, dissertation, 2009, just in several characters seems as twin of IGNITION through IceCube document project held since Oct 11, 2001 ever concludes as ``saw none'' so they can be follows the ITER/IFMIF. Refers to S29286 file in UI retrieved: ``magnetic quantum-dot cellular automata which is nonvolatile & lower power consist of nanomagnets. Since they are magnetically coupled, logic can be performed by switching, on the other hand in a DOMINO fashion..'' [A. Klenm: ``Fabrication of Magnetic Tunnel Junction-based Spintronic Devices..,'' convocation, Aug 11-14, 2010]. Acknowledgments devotes to BB Mandelbrot: ``Fractal Geometry: What is it & What Does it do?''.

  1. A nanomagnetic study of phase transition in manganite thin films and ballistic magnetoresistance in magnetic nanocontacts

    Science.gov (United States)

    Chung, Seok-Hwan

    This work focuses on two largely unexplored phenomena in micromagnetics: the temperature-driven paramagnetic insulator to ferromagnetic (FM) metallic phase transition in perovskite manganite and ballistic magnetoresistance in spin-polarized nanocontacts. To investigate the phase transition, an off-the-shelf commercial scanning force microscope was redesigned for operation at temperatures from 350 K to 100 K. This adaptation is elaborated in this thesis. Using this system, both ferromagnetic and charge-ordered domain structures of (La 1-xPrx)0.67Ca0.33MnO3 thin film were observed by magnetic force microscopy (MFM) and electric force microscopy (EFM) operated in the vicinity of the peak resistance temperature (Tp). Predominantly in-plane oriented FM domains of sub-micrometer size emerge below Tp and their local magnetic moment increased as the temperature is reduced. Charge-ordered insulating regions show a strong electrostatic interaction with an EFM tip at a few degrees above Tp and the interaction correlates well with the temperature dependence of resistivity of the film. Cross-correlation analysis between topography and magnetic structure on several substrates indicates FM domains form on the flat regions of the surface, while charge ordering occurs at surface protrusions. In the investigation of ballistic magnetoresistance, new results on half-metallic ferromagnets formed by atomic or nanometer contacts of CrO2-CrO 2 and CrO2-Ni are presented showing magnetoconductance as high as 400%. Analysis of the magnetoconductance versus conductance data for all materials known to exhibit so-called ballistic magnetoresistance strongly suggests that magnetoconductance of nanocontacts follows a universal mechanism. If the maximum magnetoconductance is normalized to unity and the conductance is scaled with the resistivity of the material, then all data points fall onto a universal curve independent of the contact material and the transport mechanism. The analysis has been applied to all available magnetoconductance data of magnetic nanocontacts in the literature. The results are in agreement with a theory that takes into account only the spin-scattering within a magnetic domain wall and are independent of whether the transport is ballistic or diffusive.

  2. Development and structural characterization of exchange-spring-like nanomagnets in (Fe,Co)-Pt bulk nanocrystalline alloys

    Energy Technology Data Exchange (ETDEWEB)

    Crisan, O.; Crisan, A.D.; Mercioniu, I. [National Institute for Materials Physics, P.O. Box MG-7, 077125 Magurele, Bucharest (Romania); Nicula, R. [Empa, Swiss Federal Laboratories for Materials Science and Technology, Advanced Materials Processing, Feuerwerkerstr. 39, CH-3602 Thun (Switzerland); Vasiliu, F., E-mail: fvasiliu@infim.ro [National Institute for Materials Physics, P.O. Box MG-7, 077125 Magurele, Bucharest (Romania)

    2016-03-01

    FePt-based alloys are currently under scrutiny for their possible use as materials for perpendicular magnetic recording. Another possible application is in the field of permanent magnets without rare-earths, magnets that may operate at higher temperatures than the classic Nd–Fe–B magnets. Within this study, FeCoPt alloys prepared by rapid solidification from the melt are structurally and magnetically characterized. In the as-cast FeCoPt ribbons, a three-phase structure comprising well-ordered CoFePt and CoPt L1{sub 0} phases embedded in a disordered fcc FePt matrix was evidenced by XRD, HREM and SAED. Extended transmission electron microscopy analysis demonstrates the incipient formation of ordered L1{sub 0} phases. X-ray diffraction was used to characterize the phase structure and to obtain the structural parameters of interest for L1{sub 0} ordering. In the as-cast state, the co-existence of hard magnetic CoFePt and CoPt L1{sub 0} tetragonal phases with the soft fcc FePt phase is obtained within a refined microstructure made of alternatively disposed grains (grain sizes from 1 to 7 nm). Following a thermal treatment of 1 h at 670 °C, the soft magnetic fcc matrix phase transforms to tetragonal L1{sub 0} phases (disorder–order transition). The resulting CoPt and CoFePt L1{sub 0} phases have grains of around 5–20 nm in size. In the as-cast state, magnetic measurements show a quite large remanence (0.75 T), close to the value of the parent L1{sub 0} FePt phase. Coercive fields of about 200 kA/m at 5 K were obtained, comparable with those reported for some FePt-based bulk alloys. Upon annealing both remanence and coercivity are increased and values of up to 254 kA/m at 300 K are obtained. The polycrystalline structure of the annealed FeCoPt samples, as well as the formation of multiple c-axis domains in different CoPt and CoFePt regions (which leads to a reduction of the magneto-crystalline anisotropy) may account for the observed coercive fields that are lower than in the case of very thin FeCoPt films. A Curie temperature of about 820 K (close to 550 °C) is reported for the Fe{sub 35}Co{sub 15}Pt{sub 50} alloy which opens wide possibilities for the use of such magnets in high operating temperature industrial applications. The present results indicate that ternary FeCoPt alloys hold a great potential as a novel class of rare earth free exchange-spring coupled nanocomposite magnets. - Highlights: • Melt-spun FeCoPt alloy ribbons are structurally and magnetically characterized. • In as-cast state there are well-ordered CoFePt and CoPt L10 grains in fcc FePt. • After annealing, the soft magnetic fcc phase transforms to tetragonal L10 phases. • A large remanence and coercivity are obtained in as-cast and annealed state.

  3. Detection of Ustilago nuda (Jensen Rostrup in winter barley seed

    Directory of Open Access Journals (Sweden)

    Ignjatov Maja

    2011-01-01

    Full Text Available Barley is one of the most important cereals grown in our agroecological conditions. The causal agent of loose smut on barley Ustilago nuda (Jensen Rostrup occurs frequently as varieties susceptible to this pathogen are present in the production. Disease symptoms are manifested on barley head (spike. Parasite is transmitted by seed (seedborne and stays in the embryo tissue of the infected kernel as dormant mycelium. Recommended method for detection of U. nuda is given by ISTA Rules (method 7-013. In tests, nine samples (weighing 120 g each of naturally infected barley seed (about 1000 seeds, depending on the absolute mass of seed were examined, observed and described using a Zeiss microscope with sub stage illumination with magnification range x 40 or higher. Mycelium of the fungus approximately 3 μ thick, golden brown in colour was detected and visible without a stain. The percentage of infected embryos in the examined samples of barley seeds ranged from 0.8% to 5.2%.

  4. On the construction of a 2-metre mirror blank for the universal reflecting telescope in Tautenburg (German Title: Über die Fertigung eines 2-Meter-Spiegelträgers für das Universal-Spiegelteleskop in Tautenburg )

    Science.gov (United States)

    Lödel, Wolfgang

    The astronomers' desire to penetrate deeper into space transforms into a demand for larger telescopes. The primary mirror constitutes the main part of a reflecting telescope, and it determines all subsequent activities. Already in the 1930s activities existed in the Schott company to manufacture mirror blanks up to diameters of 2 metres, which could not be pursued because of political constraints. This ambitious goal was again picked up a few years after the war. At a time when the procurement of raw materials was extremely difficult, the glass workers of Schott in Jena attacked this large project. After some failures, a good mirror blank could be delivered to the Carl Zeiss Company in 1951 for further processing and for the construction of the first 2-metre reflecting telescope. From 1960 to 1986, this mirror made from optical glass ZK7 served its purpose at the Karl Schwarzschild Observatory in Tautenburg. lt was then replaced by a zero expansion glass ceramics mirror.

  5. [Regeneration of the ciliary beat of human ciliated cells].

    Science.gov (United States)

    Wolf, G; Koidl, B; Pelzmann, B

    1991-10-01

    The influence of an isotonic, alkaline saline solution (diluted "Emser Sole" or brine from the spa of Bad Ems) on the ciliary beat of isolated cultured human ciliated cells of the upper respiratory tract was investigated. The ciliary beat was observed via an inverted phase contrast microscope (Zeiss Axiomat IDPC) and measured microphotometrically under physiological conditions and after the damaging influence of 1% propanal solution. Under physiological conditions the saline solution had a positive, although statistically not significant influence on the frequency of the ciliary beat. After damage of the cultivated cells by 1% propanal solution, the saline solution had a significant better influence on the regeneration of the cultured cells than a physiological sodium chloride solution. It is concluded that diluted brine from Bad Ems has a positive effect on the ciliary beat of the respiratory epithelium and accelerates its regeneration after damage by viral and bacterial infections, surgery or inhaled noxae.

  6. Sample Preparation and Mounting of Drosophila Embryos for Multiview Light Sheet Microscopy.

    Science.gov (United States)

    Schmied, Christopher; Tomancak, Pavel

    2016-01-01

    Light sheet fluorescent microscopy (LSFM), and in particular its most widespread flavor Selective Plane Illumination Microscopy (SPIM), promises to provide unprecedented insights into developmental dynamics of entire living systems. By combining minimal photo-damage with high imaging speed and sample mounting tailored toward the needs of the specimen, it enables in toto imaging of embryogenesis with high spatial and temporal resolution. Drosophila embryos are particularly well suited for SPIM imaging because the volume of the embryo does not change from the single cell embryo to the hatching larva. SPIM microscopes can therefore image Drosophila embryos embedded in rigid media, such as agarose, from multiple angles every few minutes from the blastoderm stage until hatching. Here, we describe sample mounting strategies to achieve such a recording. We also provide detailed protocols to realize multiview, long-term, time-lapse recording of Drosophila embryos expressing fluorescent markers on the commercially available Zeiss Lightsheet Z.1 microscope and the OpenSPIM.

  7. Hungarian repeat station survey, 2010

    Directory of Open Access Journals (Sweden)

    Péter Kovács

    2013-03-01

    Full Text Available The last Hungarian repeat station survey was completed between October 2010 and February 2011. Declination, inclination and the total field were observed using one-axial DMI fluxgate magnetometer mounted on Zeiss20A theodolite and GSM 19 Overhauser magnetometer. The magnetic elements of the sites were reduced to the epoch of 2010.5 on the basis of the continuous recordings of Tihany Geophysical Observatory. In stations located far from the reference observatory, the observations were carried out in the morning and afternoon in order to decrease the effect of the distant temporal correction. To further increase the accuracy, on-site dIdD variometer has also been installed near the Aggtelek station, in the Baradla cave, during the survey of the easternmost sites. The paper presents the technical details and the results of our last campaign. The improvement of the accuracy of the temporal reduction by the use of the local variometer is also reported.

  8. Radiographically detectable intracortical porosity

    International Nuclear Information System (INIS)

    Meema, H.E.

    1986-01-01

    Since the measurement of intracortical resorptive spaces by histologic methods is difficult and very few data are available in normal humans, we have measured their lengths and widths and calculated the intracortical porosity in metacarpals and phalanges of 79 normal women and 69 normal men, using fine-detail radiographs of the hands and a computerized semi-automatic image analysis system (Zeiss MOP-3), this being the first study of this kind. Several methodological problems were solved satisfactorily, and the results of this study could serve as a data bank for further investigations concerned with intracortical resorption. Significant differences were found between age and sex versus several intracortical resorptive parameters; also significant correlations were found with age in some cases. Normal intracortical porosity was found to be about three times greater in the proximal phalanges than in the metacarpals. It is concluded that this methodology could be used for further studies of intracortical resorption in osteoporosis and other metabolic bone diseases. (orig.)

  9. Classic Telescopes A Guide to Collecting, Restoring, and Using Telescopes of Yesteryear

    CERN Document Server

    English, Neil

    2013-01-01

    Classic Telescopes explores the exciting world of telescopes past, as well as the possibilities involved in acquiring these instruments. What are classic telescopes? First, the book takes a look at the more traditional telescopes built by the great instrument makers of the eighteenth and nineteenth centuries and the dynastic houses founded by the likes of John Dollond, Alvan Clark, Thomas Cooke & Sons and Carl Zeiss, plus some lesser-known luminaries, including John Brashear, John Calver, and Henry Fitz. Instruments constructed from the 1950s until as recently as the early 1990s are now also considered 'classic.' There is thus a very active market for buying and selling these 'modern' classics. The author examines some of the most talked about instruments on the amateur Internet forums, including the Unitron refractors, the Questar 90, a classic 6-inch reflector, the RV-6; a 3-inch F/15 achromat by Fullerscopes; the time-honored AstroScan Richfield reflector; and many, many more. Classic telescopes are of...

  10. Suitability of N2 plasma for the RIE etching of thin Ag layers

    International Nuclear Information System (INIS)

    Hrkut, P.; Matay, L.; Kostic, I.; Bencurova, A.; Konecnikova, A.; Nemec, P.; Andok, R.; Hacsik, S.

    2013-01-01

    Silver layers of 48 nm thickness were evaporated using EB PVD on Si wafers. The masking resist layers were spin-coated and patterned by the EBDW lithography on the ZBA 21 (20 keV) (Carl-Zeiss, Jena; currently Vistec, Ltd.) variable shaped e-beam pattern generator in II SAS. In order to check the etching process in N 2 , we covered a part of the samples containing Ag with a layer of various resists. The samples were dried on a hot-plate and RIE etched in SCM 600 (1 Pa; 20 sccm; 500 W). After 8 minutes the non-masked Ag layer was completely etched away, what testified suitability of N 2 as an etching gas. Also the etch time of 4 minutes showed to be sufficient for etching through the Ag layer. In order to optimize the etching process it was necessary to estimate the etch-rate (E.R.) of suitable resist layers and of the silver layer. The (authors)

  11. Four-year to seven-year outcomes of advanced surface ablation with excimer laser for high myopia

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    2015-01-01

    Purpose: To evaluate and compare long-term outcomes ofafter photorefractive keratectomy with cooling (cPRK) and laser-assisted subepithelial keratectomy (LASEK) for high myopia. Methods: Retrospective single-masked follow-up study of patients treated for myopia between 2007 and 2009 with cPRK...... or LASEK, using a high-frequency flying-spot excimer laser with eye-tracker (MEL80; Carl Zeiss, Jena, Germany). One eye of each patient was randomly chosen for analysis. Re-treated eyes were excluded. Results: Forty-six cPRK patients and 35 LASEK patients were included. Spherical equivalent averaged -7.......69 ± 1.47 diopters (D) in cPRK eyes and -7.98 ± 2.06 D in LASEK eyes (P=0.31) before surgery. Average follow-up time was 4.6 years in cPRK patients and 6.0 years in LASEK patients (PPRK eyes and 1 LASEK eye (P=0.46) had lost 2 lines of corrected distance visual acuity...

  12. Intraoperative magnetic resonance imaging to update interactive navigation in neurosurgery: method and preliminary experience.

    Science.gov (United States)

    Wirtz, C R; Bonsanto, M M; Knauth, M; Tronnier, V M; Albert, F K; Staubert, A; Kunze, S

    1997-01-01

    We report on the first successful intraoperative update of interactive image guidance based on an intraoperatively acquired magnetic resonance imaging (MRI) date set. To date, intraoperative imaging methods such as ultrasound, computerized tomography (CT), or MRI have not been successfully used to update interactive navigation. We developed a method of imaging patients intraoperatively with the surgical field exposed in an MRI scanner (Magnetom Open; Siemens Corp., Erlangen, Germany). In 12 patients, intraoperatively acquired 3D data sets were used for successful recalibration of neuronavigation, accounting for any anatomical changes caused by surgical manipulations. The MKM Microscope (Zeiss Corp., Oberkochen, Germany) was used as navigational system. With implantable fiducial markers, an accuracy of 0.84 +/- 0.4 mm for intraoperative reregistration was achieved. Residual tumor detected on MRI was consequently resected using navigation with the intraoperative data. No adverse effects were observed from intraoperative imaging or the use of navigation with intraoperative images, demonstrating the feasibility of recalibrating navigation with intraoperative MRI.

  13. [A comparison of rebound tonometry (ICare) with TonoPenXL and Goldmann applanation tonometry].

    Science.gov (United States)

    Schreiber, W; Vorwerk, C K; Langenbucher, A; Behrens-Baumann, W; Viestenz, A

    2007-04-01

    Goldmann applanation tonometry and dynamic contour tonometry (PASCAL) are two well established slit lamp mounted tonometric methods. Intraocular pressure measurement in bedridden patients and children is often only possible using hand held tonometers (TonoPenXL, Perkins tonometer, Draeger tonometer). This study was performed to evaluate the hand held ICare tonometer, which is based on the rebound method. A total of 102 eyes were examined by two highly experienced ophthalmologists for: 1) ophthalmological status, 2) central corneal power (Zeiss IOL-Master), 3) central corneal thickness (Tomey ultrasound pachymetry, five successive measurements, SDr=0.592-0.642; p<0.001). There was a great intra-individual variability of up to 17 mmHg between the GAT, TonoPenXL and ICare methods. The ICare tonometer is easy to handle and high reliability. The data are comparable with those from the Goldmann tonometer. A tonography effect of 0.6 mmHg in the successive measurement series was found.

  14. Oculometry findings in high myopia at adult age: considerations based on oculometric follow-up data over 28 years in a cohort-based Danish high-myopia series

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Goldschmidt, Ernst

    2010-01-01

    PURPOSE: To present and discuss oculometry data in a series of adults with high myopia followed between the ages of 26 and 54 years. Emphasis is on axial length (AL) findings and corneal curvature radius (Crad). METHODS: Thirty-four out of the 39 individuals recruited as teenagers from a Copenhagen...... 1948 birth cohort with myopia of at least 6 D have had current follow-up exams, to include AL measurements (by ultrasound, 1974-2002; the latter year also with the Zeiss IOLMaster) and keratometry. The cross-sectional and longitudinal analyses are based primarily on the eyes with high myopia; however......, the fellow eye is also assessed in unilateral cases. RESULTS: At age 54 years, the maximum myopia in the series was -26 D; the highest AL value was 35.4 mm. The myopia had increased in most, with an increase from the 26-year oculometry baseline averaging 1.0 D [standard deviation (SD) 1.84]. Ultrasound...

  15. Cone dysfunctions in retinitis pigmentosa with retinal nerve fiber layer thickening.

    Science.gov (United States)

    Sobacı, Güngör; Ozge, Gökhan; Gündoğan, Fatih Ç

    2012-01-01

    To investigate whether or not thicker retinal nerve fiber layer (RNFL) in retinitis pigmentosa (RP) patients relates to functional abnormalities of the photoreceptors. Optical coherence tomography-based RNFL thickness was measured by Stratus-3™ (Zeiss, Basel, Switzerland) optical coherence tomography and electroretinogram (ERG) recordings made using the RETI-port(®) system (Roland, Wiesbaden, Germany) in 27 patients with retinitis pigmentosa and in 30 healthy subjects. Photopic ERG b-wave amplitude, cone ERG b-wave latency, 30 Hz flicker amplitude, and 30 Hz flicker latency had significant correlations to the RNFL-temporal (r = -0.55, P = 0.004, r = 0.68, P = 0.001, r = -0.65, P = 0.001, and r = -0.52, P = 0.007, respectively). Eyes with thicker RNFL (ten eyes) differed significantly from those with thinner RNFL (eight eyes) regarding cone ERG b-wave latency values only (P = 0.001). Thicker RNFL in patients with retinitis pigmentosa may be associated with functional abnormality of the cone system.

  16. Contributions to the History of Astronomy, Vol. 7 (German Title: Beiträge zur Astronomiegeschichte, Band 7)

    Science.gov (United States)

    Dick, Wolfgang R.; Hamel, Jürgen

    The topics of this volume extend from the work of the islamic scienticst al-Tusi in the 13th century to the development of astronomical instrumentation at the Carl Zeiss Jena Company in the second half of the 20th century. The contents of the remaining articles are found between these limits: the well-known textbooks of Johannes de Sacrobosco, Tycho Brahe's stays in Augsburg, Gottfried Kirch's calendars, published around 1700, a portrait of Bessel, made during his Königsberg time, Fraunhofer's successors at the Munich Optical Institute, and Einstein's cosmological ideas in his ``Four lectures on the Theory of Relativity''. The earliest disputation of the learned Jesuit Christoph Scheiner is printed for the first time in a German translation. The volume is concluded by a bibliographical overview on historical Venus transits, additional short notes, an obituary of Jerzy Dobrzycki, and book reviews. Most papers are written in German. Main papers have English abstracts.

  17. Griffith Observatory: Hollywood's Celestial Theater

    Science.gov (United States)

    Margolis, Emily A.; Dr. Stuart W. Leslie

    2018-01-01

    The Griffith Observatory, perched atop the Hollywood Hills, is perhaps the most recognizable observatory in the world. Since opening in 1935, this Los Angeles icon has brought millions of visitors closer to the heavens. Through an analysis of planning documentation, internal newsletters, media coverage, programming and exhibition design, I demonstrate how the Observatory’s Southern California location shaped its form and function. The astronomical community at nearby Mt. Wilson Observatory and Caltech informed the selection of instrumentation and programming, especially for presentations with the Observatory’s Zeiss Planetarium, the second installed in the United States. Meanwhile the Observatory staff called upon some of Hollywood’s best artists, model makers, and scriptwriters to translate the latest astronomical discoveries into spectacular audiovisual experiences, which were enhanced with Space Age technological displays on loan from Southern California’s aerospace companies. The influences of these three communities- professional astronomy, entertainment, and aerospace- persist today and continue to make Griffith Observatory one of the premiere sites of public astronomy in the country.

  18. American Society for Therapeutic Radiology and Oncology (ASTRO) Emerging Technology Committee Report on Electronic Brachytherapy

    International Nuclear Information System (INIS)

    Park, Catherine C.; Yom, Sue S.; Podgorsak, Matthew B.; Harris, Eleanor; Price, Robert A.; Bevan, Alison; Pouliot, Jean; Konski, Andre A.; Wallner, Paul E.

    2010-01-01

    The development of novel technologies for the safe and effective delivery of radiation is critical to advancing the field of radiation oncology. The Emerging Technology Committee of the American Society for Therapeutic Radiology and Oncology appointed a Task Group within its Evaluation Subcommittee to evaluate new electronic brachytherapy methods that are being developed for, or are already in, clinical use. The Task Group evaluated two devices, the Axxent Electronic Brachytherapy System by Xoft, Inc. (Fremont, CA), and the Intrabeam Photon Radiosurgery Device by Carl Zeiss Surgical (Oberkochen, Germany). These devices are designed to deliver electronically generated radiation, and because of their relatively low energy output, they do not fall under existing regulatory scrutiny of radioactive sources that are used for conventional radioisotope brachytherapy. This report provides a descriptive overview of the technologies, current and future projected applications, comparison of competing technologies, potential impact, and potential safety issues. The full Emerging Technology Committee report is available on the American Society for Therapeutic Radiology and Oncology Web site.

  19. Nanomagnetic intergrowths in Fe-Ni meteoritic metal: The potential for time-resolved records of planetesimal dynamo fields

    DEFF Research Database (Denmark)

    Bryson, James F.J.; Church, Nathan S.; Kasama, Takeshi

    2014-01-01

    been imaged using off-axis electron holography. The CZ is revealed to be a natural nanocomposite of magnetically hard islands of tetrataenite (ordered FeNi) embedded in a magnetically soft matrix of ordered Fe3Ni. In the remanent state, each tetrataenite island acts as a uniaxial single domain particle......) varies with the length scale of the matrix phase (Lm), with Hs > 1 T for Lm ∼10 nm (approaching the intrinsic switching field for isolated single domain tetrataenite) and 0.2hard tetrataenite...... field could have been present during nanostructure formation. This observation demonstrates the potential for stable chemical transformation remanent magnetisation to be encoded by the nanostructure, with variations in the proportions of the six possible magnetisation states reflecting the intensity...

  20. Few-nanosecond pulse switching with low write error for in-plane nanomagnets using the spin-Hall effect

    Science.gov (United States)

    Aradhya, Sriharsha; Rowlands, Graham; Shi, Shengjie; Oh, Junseok; Ralph, D. C.; Buhrman, Robert

    Magnetic random access memory (MRAM) using spin transfer torques (STT) holds great promise for replacing existing best-in-class memory technologies in several application domains. Research on conventional two-terminal STT-MRAM thus far has revealed the existence of limitations that constrain switching reliability and speed for both in-plane and perpendicularly magnetized devices. Recently, spin torque arising from the giant spin-Hall effect in Ta, W and Pt has been shown to be an efficient mechanism to switch magnetic bits in a three-terminal geometry. Here we report highly reliable, nanosecond timescale pulse switching of three-terminal devices with in-plane magnetized magnetic tunnel junctions. We obtain write error rates (WER) down to ~10-5 using pulses as short as 2 ns, in contrast to conventional in-plane STT-MRAM devices where write speeds were limited to a few tens of nanoseconds for comparable WER. Utilizing micro-magnetic simulations, we discuss the differences from conventional MRAM that allow for this unanticipated and significant performance improvement. Finally, we highlight the path towards practical application enabled by the ability to separately optimize the read and write pathways in three-terminal devices.

  1. Nanomagnetic behavior of fullerene thin films in Earth magnetic field in dark and under polarization light influences.

    Science.gov (United States)

    Koruga, Djuro; Nikolić, Aleksandra; Mihajlović, Spomenko; Matija, Lidija

    2005-10-01

    In this paper magnetic fields intensity of C60 thin films of 60 nm and 100 nm thickness under the influence of polarization lights are presented. Two proton magnetometers were used for measurements. Significant change of magnetic field intensity in range from 2.5 nT to 12.3 nT is identified as a difference of dark and polarization lights of 60 nm and 100 nm thin films thickness, respectively. Specific power density of polarization light was 40 mW/cm2. Based on 200 measurement data average value of difference between magnetic intensity of C60 thin films, with 60 nm and 100 nm thickness, after influence of polarization light, were 3.9 nT and 9.9 nT respectively.

  2. Efeito do meio Erd Schreiber no cultivo das microalgas Dunaliella salina, Tetraselmis chuii e Isochrysis galbana = Erd Schreiber medium effect in culture of microalgae Dunaliella salina, Tetraselmis chuii and Isochrysis galbana

    Directory of Open Access Journals (Sweden)

    Vera Lucia Mota Klein

    2006-04-01

    Full Text Available As microalgas são utilizadas como fonte de alimento em aqüicultura. Neste trabalho cultivaram-se D. salina, T. chuii e I. galbana. O objetivo do trabalho consistiu em determinar o efeito do meio Erd Schreiber sobre o seu crescimento. Iniciou-se o cultivo com a mistura de 200 mg de Na2HPO4,7H2O, 100 mg de NaNO3 e 50 mL de extrato de solo. No monitoramento, manteve-se a temperatura entre 24 - 28 oC, a salinidade a 34 ppt, à iluminação constante, a densidade celular com uma câmara de Neubauer e um microscópio binocular modelo ZEISS. Como resultado, I. galbana, D. salina e T. chuii atingiram 969 104 cel/mL, 457 x 104 cel/mL e 258,66 x 104 cel/mL, respectivamente, e oscoeficientes angulares b foram 3,76 x 104 cel./mL/dia, 6,84 x 104 cel./mL/dia e 2,08 x 104 cel./mL/dia respectivamente, indicando bom desempenho de todas as microalgas no meio Erd Shreiber.The microalgae is used as food source in aqüicultura. In this work they had cultivated D. salina , T. chuii and I. galbana . The objective of the work is to determine the effect of Erd Schreiber´s culture medium on the microalgae growth. The culture initiated mixting 200mg of Na2HPO4,7H2O, 100 mg of NaNO3 and 50 mL of soil extract. During the culture the temperature had varied between 24 and 28oC, the salinity was fixed on 34 %o, and the illumination was maintained constant. The assessment of the culture was made by a chamber of Neubauer and a binocular microscope ZEISS model. As result I. galbana D. salina and T.chuii reached 969 104 cel/mL, 457 x 104cel/mL and 258,66 x 104 cel/mL respectively and as angular coefficient 3,76 x 104 cel/mL/dia, 6,84 x 104 cel/mL/dia and 2,08 104 x cel/mL/dia respectively, showing good answer of the microalgae to the effect of Erd Schreiber´ s medium.

  3. Nitric oxide-dependent vasodilation and Ca2+ signalling induced by erythrodiol in rat aorta

    Directory of Open Access Journals (Sweden)

    Fidèle Ntchapda

    2015-06-01

    Full Text Available Objective: To evaluate the pharmacological property of erythrodiol, a natural triterpenoid contained in propolis, as vasodilatory agent, and to determine its mechanism of action. Methods: Rats aortic rings were isolated and suspended in organ baths, and the effects of erythrodiol were studied by means of isometric tension recording experiments. Nitric oxide (NO was detected by ozone-induced chemiluminescence. The technique used to evaluate changes in intracellular Ca2+ concentration in intact endothelium was opened aortic ring and loaded with 16 µmol Fura-2/AM for 60 min at room temperature, washed and fixed by small pins with the luminal face up. In situ, ECs were visualized by an upright epifluorescence Axiolab microscope (Carl Zeiss, Oberkochen, Germany equipped with a Zeiss×63 Achroplan objective (water immersion, 2.0 mm working distance, 0.9 numerical apertures. ECs were excited alternately at 340 and 380 nm, and the emitted light was detected at 510 nm. Results: In aortic rings with intact endothelium pre-contracted with norepinephrine (10-4 mol/L, the addition of erythrodiol (10-8-10-4 mol/L induced vasorelaxation in a concentration-dependent manner; in endothelium-denuded rings, the relaxant response induced by erythrodiol was almost completely abolished suggesting that vasorelaxation was endothelium-dependent. They had almost no relaxant effect on depolarised or endothelium-denuded aortic segments. The relaxation was significantly attenuated by pre-treatment with the NO synthase inhibitor Nvnitro-L-arginine-methylester. Erythrodiol (10-4 mol/L was able to significantly increase NOx levels. This effect was completely abolished after removal of the vascular endothelium. Erythrodiol (100 µmol/L caused a slow, long-lasting increase in intracellular Ca2+ concentration. These results further supported the hypothesis that erythrodiol can induce activation of the NO/soluble guanylate cyclase/cyclic guanosine monophosphate pathway, as

  4. MORPHOLOGICAL CHANGES IN THE HIPPOCAMPUS OF RATS IN ACCELERATED AGING

    Directory of Open Access Journals (Sweden)

    K. Yu. Maksimova

    2014-01-01

    Full Text Available The aim of this work was the analysis of structural changes with age in the hippocampus of senescenceaccelerated OXYS rats when signs of accelerated brain aging are missing (age 14 days, developments (age 5 months, and active progresses (age 15 months. The study was performed on 15 OXYS rats and 15 Wistar rats (as a control. After dislocation, brains were dissected, fixed with 10% formalin, embedded in paraffin, and serially cut in coronal sections (5μm thickness. These sections were stained with Cresyl violet and examined with a photomicroscope (Carl Zeiss Axiostar plus, Germany. The total number of hippocampal pyramidal cells in the CA1, CA3 and the dentate gyrus regions were estimated in 14-dayold, 5and 15-month-old OXYS and Wistar rats (n = 5 on the 5 slices of each brain sections. The number of neurons with chromatolysis, hyperchromatic with darkly stained cytoplasm and shrunken neurons were calculated as degenerative neurons. The pictures obtained with the program Carl Zeiss Axio Vision 8.0 with increasing 10  100, determined the average area bodies and nuclei of neurons (mkm2. The significant structural changes of neurons in the CA1, CA3 and dentate gyrus regions of the hippocampus in OXYS rats at 5 month of age are revealed by light microscopy. This results indicates the early develop neurodegeneration in OXYS rats. The most pronounced morphological changes occur in the CA1 region of the hippocampus of OXYS rats and irreversible. The degenerative changes of neurons in the hippocampus increases by the age of 15 months. Morphometric analysis of the average area of bodies and the nuclei of hippocampal neurons in CA1, CA3 and the dentate gyrus regions of OXYS and Wistar rats at 14 days of age showed no significant interline differences. At 5 months of age in the CA1 region of the hippocampus of OXYS rats was determined a significantly lower average body size and nuclei of pyramidal neurons compared with Wistar rats. With age, these

  5. TARGIT-E(lderly—Prospective phase II study of intraoperative radiotherapy (IORT in elderly patients with small breast cancer

    Directory of Open Access Journals (Sweden)

    Neumaier Christian

    2012-05-01

    Full Text Available Abstract Background Patients ≥ 70 years with small, low-risk breast cancer who are operated but not irradiated how local relapse rates around 4% after 4 years. With adjuvant whole breast radiotherapy (WBRT the local relapse rate drops to 1% after 4 years under Tamoxifen. It has been demonstrated that the efficacy of radiotherapy of the tumor bed only in a selected group can be non-inferior to WBRT. Methods/Design This prospective, multicentric single arm phase II study is based on the protocol of the international TARGIT-A study. The TARGIT-E study should confirm the efficacy of a single dose of intraoperative radiotherapy (IORT in a well selected group of elderly patients with small breast cancer and absence of risk factors. Patients will receive IORT (20 Gy with Intrabeam system/Carl Zeiss during breast conserving surgery. In presence of risk factors postoperative WBRT will be added to complete the radiotherapeutic treatment according to international guidelines. Endpoints are the local relapse rate (within 2 cm of the tumor bed, ipsilateral in breast relapse, cancer-specific and overall survival and contralateral breast cancer as well as documentation of quality of life and cosmetic outcome. The expected local relapse rates are 0.5/1/1.5% after 2.5/5/7.5 years, respectively. Discontinuation of the trial is scheduled if rates of local relapse rates rise to 3/4/6% after 2.5/5/7.5 years. Power calculations result in 540 patients with a calculated dropout rate of 20% and loss to follow-up of 20%, an alpha of 0.01 and a beta 0.05. There will be a pre- and a post-pathology stratum (n = 270 each. Discussion It is a pragmatic trial in which each participating centre has the option to modify entry criteria and criteria for WBRT according to this core protocol after consultation with the steering committee and local ethics committee (e.g. size, free margins. Only centers with access to the Intrabeam system (Carl Zeiss can

  6. Magnetization reversal in single molecule magnets

    Science.gov (United States)

    Bokacheva, Louisa

    2002-09-01

    I have studied the magnetization reversal in single molecule magnets (SMMs). SMMs are Van der Waals crystals, consisting of identical molecules containing transition metal ions, with high spin and large uniaxial magnetic anisotropy. They can be considered as ensembles of identical, iso-oriented nanomagnets. At high temperature, these materials behave as superparamagnets and their magnetization reversal occurs by thermal activation. At low temperature they become blocked, and their magnetic relaxation occurs via thermally assisted tunneling or pure quantum tunneling through the anisotropy barrier. We have conducted detailed experimental studies of the magnetization reversal in SMM material Mn12-acetate (Mn12) with S = 10. Low temperature measurements were conducted using micro-Hall effect magnetometry. We performed hysteresis and relaxation studies as a function of temperature, transverse field, and magnetization state of the sample. We identified magnetic sublevels that dominate the tunneling at a given field, temperature and magnetization. We observed a crossover between thermally assisted and pure quantum tunneling. The form of this crossover depends on the magnitude and direction of the applied field. This crossover is abrupt (first-order) and occurs in a narrow temperature interval (tunneling mechanisms in Mn12.

  7. Spin orbit torque based electronic neuron

    Energy Technology Data Exchange (ETDEWEB)

    Sengupta, Abhronil, E-mail: asengup@purdue.edu; Choday, Sri Harsha; Kim, Yusung; Roy, Kaushik [School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907 (United States)

    2015-04-06

    A device based on current-induced spin-orbit torque (SOT) that functions as an electronic neuron is proposed in this work. The SOT device implements an artificial neuron's thresholding (transfer) function. In the first step of a two-step switching scheme, a charge current places the magnetization of a nano-magnet along the hard-axis, i.e., an unstable point for the magnet. In the second step, the SOT device (neuron) receives a current (from the synapses) which moves the magnetization from the unstable point to one of the two stable states. The polarity of the synaptic current encodes the excitatory and inhibitory nature of the neuron input and determines the final orientation of the magnetization. A resistive crossbar array, functioning as synapses, generates a bipolar current that is a weighted sum of the inputs. The simulation of a two layer feed-forward artificial neural network based on the SOT electronic neuron shows that it consumes ∼3× lower power than a 45 nm digital CMOS implementation, while reaching ∼80% accuracy in the classification of 100 images of handwritten digits from the MNIST dataset.

  8. Spin orbit torque based electronic neuron

    International Nuclear Information System (INIS)

    Sengupta, Abhronil; Choday, Sri Harsha; Kim, Yusung; Roy, Kaushik

    2015-01-01

    A device based on current-induced spin-orbit torque (SOT) that functions as an electronic neuron is proposed in this work. The SOT device implements an artificial neuron's thresholding (transfer) function. In the first step of a two-step switching scheme, a charge current places the magnetization of a nano-magnet along the hard-axis, i.e., an unstable point for the magnet. In the second step, the SOT device (neuron) receives a current (from the synapses) which moves the magnetization from the unstable point to one of the two stable states. The polarity of the synaptic current encodes the excitatory and inhibitory nature of the neuron input and determines the final orientation of the magnetization. A resistive crossbar array, functioning as synapses, generates a bipolar current that is a weighted sum of the inputs. The simulation of a two layer feed-forward artificial neural network based on the SOT electronic neuron shows that it consumes ∼3× lower power than a 45 nm digital CMOS implementation, while reaching ∼80% accuracy in the classification of 100 images of handwritten digits from the MNIST dataset

  9. Magnetic nanoparticles of NiCuZn tested in different conditions in catalysis for biodiesel; Nanoparticulas magneticas de NiCuZn testadas em diferentes condicoes na catalise para biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, J.; Silva, F.N.; Silva, A.S.; Pereira, K.R.O.; Costa, A.C.F.M., E-mail: joeldadantas@yahoo.com.br [Universidade Federal de Campina Grande (LabSMaC/UFCG), PB (Brazil). Laboratorio de Sintese de Materiais Ceramicos

    2014-07-01

    In this work it was used magnetic nanoparticles Ni{sub 0,2}Cu{sub 0,3}Zn{sub 0,5}Fe{sub 2}O{sub 4}, chemical and thermally stable, under different conditions in catalysis for biodiesel. The magnetic characteristic of such material allows the catalyst recovery after the reactions by applying a permanent magnet. It was proposed to evaluate the performance of the nanomagnetic catalyst Ni{sub 0,2}Cu{sub 0,3}Zn{sub 0,5}Fe{sub 2}O{sub 4} in the transesterification, modifying the processing variables (temperature, time, molar ratio of oil:alcohol and catalyst amount). The nanoparticles were synthesized by combustion reaction and characterized by XRD, TG, BET, magnetic measurements and gas chromatography. The results revealed the formation of inverse spinel phase, type B(AB){sub 2}O{sub 4}, presenting isotherm profile classified as type V, with hysteresis loop of type 3 (H3). The magnetic hysteresis curve showed a characteristic behavior of soft magnetic material. GC analysis confirmed that nanoparticles were catalytically active, since they were superior to the reaction conducted without the catalyst presence. Besides, the reactions suffered considerable influence due to the changes of the independent variables. (author)

  10. Magnetic nanoparticles of NiCuZn tested in different conditions in catalysis for biodiesel

    International Nuclear Information System (INIS)

    Dantas, J.; Silva, F.N.; Silva, A.S.; Pereira, K.R.O.; Costa, A.C.F.M.

    2014-01-01

    In this work it was used magnetic nanoparticles Ni_0_,_2Cu_0_,_3Zn_0_,_5Fe_2O_4, chemical and thermally stable, under different conditions in catalysis for biodiesel. The magnetic characteristic of such material allows the catalyst recovery after the reactions by applying a permanent magnet. It was proposed to evaluate the performance of the nanomagnetic catalyst Ni_0_,_2Cu_0_,_3Zn_0_,_5Fe_2O_4 in the transesterification, modifying the processing variables (temperature, time, molar ratio of oil:alcohol and catalyst amount). The nanoparticles were synthesized by combustion reaction and characterized by XRD, TG, BET, magnetic measurements and gas chromatography. The results revealed the formation of inverse spinel phase, type B(AB)_2O_4, presenting isotherm profile classified as type V, with hysteresis loop of type 3 (H3). The magnetic hysteresis curve showed a characteristic behavior of soft magnetic material. GC analysis confirmed that nanoparticles were catalytically active, since they were superior to the reaction conducted without the catalyst presence. Besides, the reactions suffered considerable influence due to the changes of the independent variables. (author)

  11. First-principles studies on 3d transition metal atom adsorbed twin graphene

    Science.gov (United States)

    Li, Lele; Zhang, Hong; Cheng, Xinlu; Miyamoto, Yoshiyuki

    2018-05-01

    Twin graphene is a new two-dimensional semiconducting carbon allotrope which is proposed recently. The structural, magnetic and electronic properties are investigated for 3d transition metal (TM) atom adsorbed twin graphene by means of GGA+U calculations. The results show most of single 3d transition metal atom except Zn can make twin graphene magnetization. The adsorption of single TM atom can also make the twin graphene systems turn to half metal (V adsorption), half-semiconductor (Fe adsorption) or metal (Sc, Cr, Mn, Co and Cu adsorption). The semiconducting nature still exists for Ti, Ni and Zn adsorption. All the 3d TM adatoms belong to n-type doping for transferring charge to the neighboring C atoms and have strong covalent bond with these C atoms. The influence of Hubbard U value on half-metallic V adsorbed system is also considered. As the U increases, the system can gradually transform from metal to half metal and metal. The effect of the coverage is investigated for two TM atoms (Sc-Fe) adsorption, too. We can know TM atoms adsorbed twin graphene have potentials to be spintronic device and nanomagnets from the results.

  12. Nanotechnology in hyperthermia cancer therapy: From fundamental principles to advanced applications.

    Science.gov (United States)

    Beik, Jaber; Abed, Ziaeddin; Ghoreishi, Fatemeh S; Hosseini-Nami, Samira; Mehrzadi, Saeed; Shakeri-Zadeh, Ali; Kamrava, S Kamran

    2016-08-10

    In this work, we present an in-depth review of recent breakthroughs in nanotechnology for hyperthermia cancer therapy. Conventional hyperthermia methods do not thermally discriminate between the target and the surrounding normal tissues, and this non-selective tissue heating can lead to serious side effects. Nanotechnology is expected to have great potential to revolutionize current hyperthermia methods. To find an appropriate place in cancer treatment, all nanotechnology-based hyperthermia methods and their risks/benefits must be thoroughly understood. In this review paper, we extensively examine and compare four modern nanotechnology-based hyperthermia methods. For each method, the possible physical mechanisms of heat generation and enhancement due to the presence of nanoparticles are explained, and recent in vitro and in vivo studies are reviewed and discussed. Nano-Photo-Thermal Therapy (NPTT) and Nano-Magnetic Hyperthermia (NMH) are reviewed as the two first exciting approaches for targeted hyperthermia. The third novel hyperthermia method, Nano-Radio-Frequency Ablation (NaRFA) is discussed together with the thermal effects of novel nanoparticles in the presence of radiofrequency waves. Finally, Nano-Ultrasound Hyperthermia (NUH) is described as the fourth modern method for cancer hyperthermia. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Electrical and magnetic behavior of iron doped nickel titanate (Fe{sup 3+}/NiTiO{sub 3}) magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Lenin, Nayagam; Karthik, Arumugam; Sridharpanday, Mathu; Selvam, Mohanraj; Srither, Saturappan Ravisekaran; Arunmetha, Sundarmoorthy; Paramasivam, Palanisamy; Rajendran, Venkatachalam, E-mail: veerajendran@gmail.com

    2016-01-01

    Iron doped nickel titanate (Fe{sup 3+}/NiTiO{sub 3}) ferromagnetic nanoparticles with different concentrations of Fe (0.2, 0.4, and 0.6 mol) were synthesized using precipitation route with precursor source such as nickel nitrate and iron nitrate solutions. The prepared magnetic nanopowders were investigated through X-ray diffraction (XRD), Fourier transform infrared, scanning electron microscope, X-ray fluorescence, Brunauer–Emmett–Teller, vibrating sample magnetometer, and electrochemical impedance spectroscopy to explore the structural, ferromagnetic, and dielectric properties. The obtained XRD pattern shows formation of iron doped nickel titanate in orthorhombic structure. The crystallite size ranges from 57 to 21 nm and specific surface area ranges from 11 to 137 m{sup 2} g{sup −1}. The hysteresis loops of nanomagnetic materials show ferromagnetic behavior with higher magnitude of coercivity (H{sub c}) 867–462 Oe. The impedance analysis of ferromagnetic materials explores the ferro-dielectric behavior with enhanced properties of Fe{sup 3+}/NiTiO{sub 3} nanoparticles at higher Fe content. - Highlights: • Iron doped nickel titanate magnetic nanoparticles. • Ferromagnetic magnetism behavior with higher magnitude of coercivity. • Dielectric behavior of ferromagnetic nanoparticles with increase of Fe content.

  14. Safety assessment of nanoparamagnetic contrast agents with different coatings for molecular MRI

    Science.gov (United States)

    Azizian, Gholamreza; Riyahi-Alam, Nader; Haghgoo, Soheila; Saffari, Mojtaba; Zohdiaghdam, Reza; Gorji, Ensieh

    2013-04-01

    Despite the wide application of gadolinium as a contrast agent for magnetic resonance imaging (MRI), there is a serious lack of information on its toxicity. Gadolinium and gadolinium oxide (Gd-oxide) are used as contrast agents for magnetic resonance imaging (MRI). There are methods for reducing toxicity of these materials, such as core nanoparticles coating or conjugating. Therefore, for toxicity evaluation, we compared the viability of commercial contrast agents in MRI (Gd-DTPA) and three nanoparticles with the same core Gd2O3 and small particulate gadolinium oxide or SPGO (DTPA. The MTT and LDH assay results showed that Gd2O3-DEG nanoparticles were more toxic than Gd-DTPA and other nanoparticles. Also, SPGO-mPEG-silane2000 was more biocompatible than other nanoparticles. The obtained results did not show any significant increase in cytotoxicity of the nanoparticles and Gd-DTPA, neither dose-dependent nor time-dependent. Therefore, DEG and PEG, due to their considerable properties and irregular sizes (different molecular weights), were selected as the useful surface covering materials of nanomagnetic particles that could reveal noticeable relaxivity and biocompatibility characteristics.

  15. Influence of the aggregation, concentration, and viscosity on the nanomagnetism of iron oxide nanoparticle colloids for magnetic hyperthermia

    International Nuclear Information System (INIS)

    Cabrera, David; Camarero, Julio; Ortega, Daniel; Teran, Francisco J.

    2015-01-01

    Iron oxide nanoparticles have become ubiquitous in many biomedical applications, acting as core elements in an increasing number of therapeutic and diagnostic modalities. These applications mainly rely on their static and dynamic magnetic properties, through which they can be remotely actuated. However, little attention has been paid to understand the variation of the magnetic response of nanoparticles inside cells or tissues, despite of the remarkable changes reported to date. In this article, we provide some hints to analyze the influence of the biological matrix on the magnetism of iron oxide nanoparticles. To this aim, we propose the assessment of the heating efficiency of magnetic colloids against nanoparticle aggregation, concentration, and viscosity in order to mimic the fate of nanoparticles upon cell internalization

  16. Acoustically assisted spin-transfer-torque switching of nanomagnets: An energy-efficient hybrid writing scheme for non-volatile memory

    International Nuclear Information System (INIS)

    Biswas, Ayan K.; Bandyopadhyay, Supriyo; Atulasimha, Jayasimha

    2013-01-01

    We show that the energy dissipated to write bits in spin-transfer-torque random access memory can be reduced by an order of magnitude if a surface acoustic wave (SAW) is launched underneath the magneto-tunneling junctions (MTJs) storing the bits. The SAW-generated strain rotates the magnetization of every MTJs' soft magnet from the easy towards the hard axis, whereupon passage of a small spin-polarized current through a target MTJ selectively switches it to the desired state with > 99.99% probability at room temperature, thereby writing the bit. The other MTJs return to their original states at the completion of the SAW cycle

  17. Influence of the aggregation, concentration, and viscosity on the nanomagnetism of iron oxide nanoparticle colloids for magnetic hyperthermia

    Energy Technology Data Exchange (ETDEWEB)

    Cabrera, David; Camarero, Julio; Ortega, Daniel; Teran, Francisco J., E-mail: francisco.teran@imdea.org [Ciudad Universitaria de Cantoblanco, IMDEA Nanociencia (Spain)

    2015-03-15

    Iron oxide nanoparticles have become ubiquitous in many biomedical applications, acting as core elements in an increasing number of therapeutic and diagnostic modalities. These applications mainly rely on their static and dynamic magnetic properties, through which they can be remotely actuated. However, little attention has been paid to understand the variation of the magnetic response of nanoparticles inside cells or tissues, despite of the remarkable changes reported to date. In this article, we provide some hints to analyze the influence of the biological matrix on the magnetism of iron oxide nanoparticles. To this aim, we propose the assessment of the heating efficiency of magnetic colloids against nanoparticle aggregation, concentration, and viscosity in order to mimic the fate of nanoparticles upon cell internalization.

  18. Custom Coordination Environments for Lanthanoids: Tripodal Ligands Achieve Near-Perfect Octahedral Coordination for Two Dysprosium-Based Molecular Nanomagnets.

    Science.gov (United States)

    Lim, Kwang Soo; Baldoví, José J; Jiang, ShangDa; Koo, Bong Ho; Kang, Dong Won; Lee, Woo Ram; Koh, Eui Kwan; Gaita-Ariño, Alejandro; Coronado, Eugenio; Slota, Michael; Bogani, Lapo; Hong, Chang Seop

    2017-05-01

    Controlling the coordination sphere of lanthanoid complexes is a challenging critical step toward controlling their relaxation properties. Here we present the synthesis of hexacoordinated dysprosium single-molecule magnets, where tripodal ligands achieve a near-perfect octahedral coordination. We perform a complete experimental and theoretical investigation of their magnetic properties, including a full single-crystal magnetic anisotropy analysis. The combination of electrostatic and crystal-field computational tools (SIMPRE and CONDON codes) allows us to explain the static behavior of these systems in detail.

  19. Ciliary body toxicities of systemic oxcarbazepine and valproic acid treatments: electron microscopic study.

    Science.gov (United States)

    Göktaş, Güleser; Aktaş, Zeynep; Erdoğan, Deniz; Seymen, Cemile Merve; Karaca, Emine Esra; Cansu, Ali; Serdaroğlu, Ayşe; Kaplanoğlu, Gülnur Take

    2015-01-01

    Ciliary body is responsible for humour aqueous production in posterior chamber. Valproic acid (VPA) has been widely used for the treatment of epilepsy and other neuropsychiatric diseases such as bipolar disease and major depression. Oxcarbazepine (OXC) is a new anti-epileptic agent that has been used recently for childhood epilepsies such as VPA. In this study, we aimed to investigate the effects of VPA and OXC treatments used as antiepileptic in ciliary body by electron microscopy. In our study, 40 Wistar rats (21 days old) were divided equally into four groups which were applied saline (group 1), VPA (group 2), OXC (group 3) and VPA + OXC (group 4). The as-prepared ocular tissues were characterized by transmission electron microscopy (TEM) technique in scanning and transmission electron microscopy (SEM-TEM) (Carl Zeiss EVO LS10). The results confirmed that VPA caused dense ciliary body degeneration. Additionally, ciliary body degeneration in group 4 was supposed to be due to VPA treatment. Ciliary body damage and secondary outcomes should be considered in patients with long-term VPA therapy.

  20. High-NA EUV lithography enabling Moore's law in the next decade

    Science.gov (United States)

    van Schoot, Jan; Troost, Kars; Bornebroek, Frank; van Ballegoij, Rob; Lok, Sjoerd; Krabbendam, Peter; Stoeldraijer, Judon; Loopstra, Erik; Benschop, Jos P.; Finders, Jo; Meiling, Hans; van Setten, Eelco; Kneer, Bernhard; Kuerz, Peter; Kaiser, Winfried; Heil, Tilmann; Migura, Sascha; Neumann, Jens Timo

    2017-10-01

    While EUV systems equipped with a 0.33 Numerical Aperture lenses are readying to start volume manufacturing, ASML and Zeiss are ramping up their activities on a EUV exposure tool with Numerical Aperture of 0.55. The purpose of this scanner, targeting an ultimate resolution of 8nm, is to extend Moore's law throughout the next decade. A novel, anamorphic lens design, capable of providing the required Numerical Aperture has been investigated; This lens will be paired with new, faster stages and more accurate sensors enabling Moore's law economical requirements, as well as the tight focus and overlay control needed for future process nodes. The tighter focus and overlay control budgets, as well as the anamorphic optics, will drive innovations in the imaging and OPC modelling. Furthermore, advances in resist and mask technology will be required to image lithography features with less than 10nm resolution. This paper presents an overview of the target specifications, key technology innovations and imaging simulations demonstrating the advantages as compared to 0.33NA and showing the capabilities of the next generation EUV systems.

  1. The future of EUV lithography: enabling Moore's Law in the next decade

    Science.gov (United States)

    Pirati, Alberto; van Schoot, Jan; Troost, Kars; van Ballegoij, Rob; Krabbendam, Peter; Stoeldraijer, Judon; Loopstra, Erik; Benschop, Jos; Finders, Jo; Meiling, Hans; van Setten, Eelco; Mika, Niclas; Dredonx, Jeannot; Stamm, Uwe; Kneer, Bernhard; Thuering, Bernd; Kaiser, Winfried; Heil, Tilmann; Migura, Sascha

    2017-03-01

    While EUV systems equipped with a 0.33 Numerical Aperture lenses are readying to start volume manufacturing, ASML and Zeiss are ramping up their development activities on a EUV exposure tool with Numerical Aperture greater than 0.5. The purpose of this scanner, targeting a resolution of 8nm, is to extend Moore's law throughout the next decade. A novel, anamorphic lens design, has been developed to provide the required Numerical Aperture; this lens will be paired with new, faster stages and more accurate sensors enabling Moore's law economical requirements, as well as the tight focus and overlay control needed for future process nodes. The tighter focus and overlay control budgets, as well as the anamorphic optics, will drive innovations in the imaging and OPC modelling, and possibly in the metrology concepts. Furthermore, advances in resist and mask technology will be required to image lithography features with less than 10nm resolution. This paper presents an overview of the key technology innovations and infrastructure requirements for the next generation EUV systems.

  2. An exercise to establish optimum procedures for the characterisation of porosity in UO2 fuel pellets

    International Nuclear Information System (INIS)

    Small, G.J.

    1980-05-01

    A standard metallographic preparation technique for UO 2 is proposed. The criteria for choosing the optimum route are that the specimen should be scratch-free and that the pores inherent to any sintered UO 2 pellet should be neither enlarged nor filled-in during preparation. Having met these criteria one has a specimen suitable for quantitative metallography which can be used to monitor porosity changes due to in-pile sintering. A procedure for analysing the porosity is suggested. This consists of imaging the specimen surface over a range of magnifications using both optical and Scanning Electron Microscopy in order to cover the range of pore sizes of interest (0.1 μm to 10 μm diameter). These images are then analysed to obtain figures for the distribution of pores as a function of diameter. Two methods of pore-size analysis are reviewed, the manual Zeiss Particle Size Analyser and a more sophisticated electronic instrument - the Quantimet. A comparison is made between these two instruments on the basis of accuracy, reproducibility and ease of operation. (author)

  3. American Society for Therapeutic Radiology and Oncology (ASTRO) Emerging Technology Committee report on electronic brachytherapy.

    Science.gov (United States)

    Park, Catherine C; Yom, Sue S; Podgorsak, Matthew B; Harris, Eleanor; Price, Robert A; Bevan, Alison; Pouliot, Jean; Konski, Andre A; Wallner, Paul E

    2010-03-15

    The development of novel technologies for the safe and effective delivery of radiation is critical to advancing the field of radiation oncology. The Emerging Technology Committee of the American Society for Therapeutic Radiology and Oncology appointed a Task Group within its Evaluation Subcommittee to evaluate new electronic brachytherapy methods that are being developed for, or are already in, clinical use. The Task Group evaluated two devices, the Axxent Electronic Brachytherapy System by Xoft, Inc. (Fremont, CA), and the Intrabeam Photon Radiosurgery Device by Carl Zeiss Surgical (Oberkochen, Germany). These devices are designed to deliver electronically generated radiation, and because of their relatively low energy output, they do not fall under existing regulatory scrutiny of radioactive sources that are used for conventional radioisotope brachytherapy. This report provides a descriptive overview of the technologies, current and future projected applications, comparison of competing technologies, potential impact, and potential safety issues. The full Emerging Technology Committee report is available on the American Society for Therapeutic Radiology and Oncology Web site. Copyright 2010. Published by Elsevier Inc.

  4. Optical coherence tomography can be used in evaluation of morphological and functional results after successful rhegmatogenous retinal detachment surgery with different tamponade agents

    Directory of Open Access Journals (Sweden)

    Tat'yana Andreevna Avanesova

    2015-03-01

    Full Text Available Background: Optical coherence tomography (OCT findings are helpful in assessing the cause of reduced visual acuity (VA after successful rhegmatogenous retinal detachment (RRD surgery. Objective: To study anatomical and functional results after successful RRD surgery with gas-air mixture or silicone oil (SO tamponade using OCT. Materials and methods. 70 patients were divided into 2 groups: group I (n = 34 - gas-air mixture tamponade; group II (n = 36 - SO tamponade. At baseline, were no significant differences by gender, age and VA between the groups. Follow-up was 12 months after the surgery. OCT was performed with the Cirrus HD-OCT 4000, CARL ZEISS MEDITEC, USA. Results: VA increased significantly in both groups. Regression analysis showed lower VA in group II and statistically significant association between VA and IS/OS and ELM defects. Сonclusions. There is a strong association of disruption of the IS/OS and ELM with reduced vision after successful retinal detachment surgery. Gas-air mixture tamponade showed some benefits in comparison with SO tamponade.

  5. Orbital single particle tracking on a commercial confocal microscope using piezoelectric stage feedback

    International Nuclear Information System (INIS)

    Lanzanò, L; Gratton, E

    2014-01-01

    Single Particle Tracking (SPT) is a technique used to locate fluorescent particles with nanometer precision. In the orbital tracking method the position of a particle is obtained analyzing the distribution of intensity along a circular orbit scanned around the particle. In combination with an active feedback this method allows tracking of particles in 2D and 3D with millisecond temporal resolution. Here we describe a SPT setup based on a feedback approach implemented with minimal modification of a commercially available confocal laser scanning microscope, the Zeiss LSM 510, in combination with an external piezoelectric stage scanner. The commercial microscope offers the advantage of a user-friendly software interface and pre-calibrated hardware components. The use of an external piezo-scanner allows the addition of feedback into the system but also represents a limitation in terms of its mechanical response. We describe in detail this implementation of the orbital tracking method and discuss advantages and limitations. As an example of application to live cell experiments we perform the 3D tracking of acidic vesicles in live polarized epithelial cells. (paper)

  6. Ultrastructural features of Mimulus aurantiacus (Scrophulariaceae) pollen tubes in vivo.

    Science.gov (United States)

    Ekici, Nuran; Dane, Feruzan; Olgun, Göksel

    2009-03-01

    The aim of this study is to give information on ultrastructure of in vivo pollen tubes of Mimulus aurantiacus which were collected from the Botanical Garden of the University of California at Berkeley. Materials were prepared according to electron microscopy methods and examined under Zeiss electron microscope. Four zones were examined in the pollen tubes of Mimulus aurantiacus. Apical zone: Mitochondria, smooth endoplasmic reticulum, rough endoplasmic reticulum, dictyosomes and secretory vesicles were observed. Subapical zone: This area contained abundant rough endoplasmic reticulum and occasionally some smooth endoplasmic reticulum. The polysomes, mitochondria, proplastids that contain starch, small vacuoles and a few lipid bodies were detected. Nuclear zone: Both generative and vegetative cell nuclei lie in this zone. The vegetative cell nucleus was large and long. Rough endoplasmic reticulum, mitochondria, ribosomes, dictyosomes, and amyloplasts that are rich of starch were observed. Vacuolation and plug formation zone: Cytoplasm of the tubes was full of large vacuoles. Few organelles such as mitochondria, dictyosome and rough endoplasmic reticulum were detected along their periphery.

  7. [Peripheral refraction and retinal contour in children with myopia by results of refractometry and partial coherence interferometry].

    Science.gov (United States)

    Tarutta, E P; Milash, S V; Tarasova, N A; Romanova, L I; Markosian, G A; Epishina, M V

    2014-01-01

    To determine the posterior pole contour of the eye based on the relative peripheral refractive error and relative eye length. A parallel study was performed, which enrolled 38 children (76 eyes) with myopia from -1.25 to -10.82 diopters. The patients underwent peripheral refraction assessment with WR-5100K Binocular Auto Refractometer ("Grand Seiko", Japan) and partial coherence tomography with IOLMaster ("Carl Zeiss", Germany) for the relative eye length in areas located 15 and 30 degrees nasal and temporal from the central fovea along the horizontal meridian. In general, refractometry and interferometry showed high coincidence of defocus signs and values for the areas located 15 and 30 degrees nasal as well as 15 degrees temporal from the fovea. However, in 41% of patients defocus signs determined by the two methods mismatched in one or more areas. Most of the mismatch cases were mild myopia. We suppose that such a mismatch is caused by optical peculiarities of the anterior eye segment that have an impact on refractometry results.

  8. Comparative analysis of imaging configurations and objectives for Fourier microscopy.

    Science.gov (United States)

    Kurvits, Jonathan A; Jiang, Mingming; Zia, Rashid

    2015-11-01

    Fourier microscopy is becoming an increasingly important tool for the analysis of optical nanostructures and quantum emitters. However, achieving quantitative Fourier space measurements requires a thorough understanding of the impact of aberrations introduced by optical microscopes that have been optimized for conventional real-space imaging. Here we present a detailed framework for analyzing the performance of microscope objectives for several common Fourier imaging configurations. To this end, we model objectives from Nikon, Olympus, and Zeiss using parameters that were inferred from patent literature and confirmed, where possible, by physical disassembly. We then examine the aberrations most relevant to Fourier microscopy, including the alignment tolerances of apodization factors for different objective classes, the effect of magnification on the modulation transfer function, and vignetting-induced reductions of the effective numerical aperture for wide-field measurements. Based on this analysis, we identify an optimal objective class and imaging configuration for Fourier microscopy. In addition, the Zemax files for the objectives and setups used in this analysis have been made publicly available as a resource for future studies.

  9. Synthesis, characterization and a.c. magnetic analysis of magnetite nanoparticles

    International Nuclear Information System (INIS)

    Riani, P.; Napoletano, M.; Canepa, F.

    2011-01-01

    In the last years, the study of Fe-based magnetic nanoparticles (MNP) has attracted increasing interest either for the physical properties shown by nanosized materials (electric and magnetic properties are strongly affected by dimension and surface effects) either for the different technological applications of these materials (catalysis, drug delivery, magnetic resonance imaging, contaminants removal from groundwater, new exchange coupled magnets, soft nanomagnets for high frequency applications, etc.). In this article, the results obtained in the synthesis and characterization of the Fe 3 O 4 MNP is reported. The magnetite nanoparticles were synthesized by a modified Massart method. Structural characterization was performed using X-ray diffraction analysis and a complete morphological and dimensional study was carried out by means of Transmission Electron Microscopy, and a.c. magnetic susceptibility measured as a function of the frequency of the applied magnetic field. Diameters of the superparamagnetic Fe 3 O 4 nanoparticles are ranging from 2 to 10 nm, as evidenced by all the techniques employed. The size distribution of the hydrated aggregates in solution has been obtained by quantitative analysis of the frequency dependence of the a.c. susceptibility. The mathematical approach adopted will be described and all the obtained results will be compared and discussed.

  10. Spin wave eigenmodes in single and coupled sub-150 nm rectangular permalloy dots

    Energy Technology Data Exchange (ETDEWEB)

    Carlotti, G., E-mail: giovanni.carlotti@fisica.unipg.it; Madami, M. [Dipartimento di Fisica e Geologia, Università di Perugia, Perugia (Italy); Tacchi, S. [Istituto Officina dei Materiali del CNR (CNR-IOM), Dipartimento di Fisica e Geologia, Perugia (Italy); Gubbiotti, G.; Dey, H.; Csaba, G.; Porod, W. [Center for Nano Science and Technology, Department of Electrical Engineering, University of Notre Dame, Notre Dame, Indiana 46556 (United States)

    2015-05-07

    We present the results of a Brillouin light scattering investigation of thermally excited spin wave eigenmodes in square arrays of either isolated rectangular dots of permalloy or twins of dipolarly coupled elements, placed side-by-side or head-to-tail. The nanodots, fabricated by e-beam lithography and lift-off, are 20 nm thick and have the major size D in the range between 90 nm and 150 nm. The experimental spectra show the presence of two main peaks, corresponding to modes localized either at the edges or in the center of the dots. Their frequency dependence on the dot size and on the interaction with adjacent elements has been measured and successfully interpreted on the basis of dynamical micromagnetic simulations. The latter enabled us also to describe the spatial profile of the eigenmodes, putting in evidence the effects induced by the dipolar interaction between coupled dots. In particular, in twinned dots the demagnetizing field is appreciably modified in proximity of the “internal edges” if compared to the “external” ones, leading to a splitting of the edge mode. These results can be relevant for the exploitation of sub-150 nm magnetic dots in new applications, such as magnonic metamaterials, bit-patterned storage media, and nano-magnetic logic devices.

  11. Simulation of the magnetocaloric effect in Tb nanofilms

    Energy Technology Data Exchange (ETDEWEB)

    Anselmo, Dory Hélio A. L., E-mail: doryh@dfte.ufrn.br [Departamento de Física Teórica e Experimental (DFTE), Universidade Federal do Rio Grande do Norte (UFRN), Natal-RN (Brazil); Mello, Vamberto D. [Departamento de Física,Universidade do Estado do Rio Grande do Norte (UERN), Mossoró-RN (Brazil); Vasconcelos, Manoel S. [Escola de Ciência e Tecnologia (ECT), Universidade Federal do Rio Grande do Norte (UFRN), Natal-RN (Brazil)

    2014-03-31

    Rare-earth (RE) metals have different magnetic structures resulting from the competition between the crystal-field and exchange interactions. When a magnetic field is applied it creates a third interaction and the magnetic structures are more complicated. In thin films, it is expected that even the magnetic arrangement itself can be strongly modified. Rare-earth helimagnets such as Terbium (Tb), Holmium (Ho) and Dysprosium (Dy) represent the best candidates to evidence such finite-size effects. This finite-size effect is caused by the reduced number of atoms in the direction perpendicular to the film plane that leads to a decrease of the total magnetic exchange energy. We report this contribution to the investigation of magnetocaloric effect (MCE) of thin Terbium films in the helimagnetic temperature range, from T{sub C} = 219 K to T{sub N} = 231 K, for external fields of the order of 1 kOe. We find that for strong fields, H = 50 kOe, the adiabatic temperature change ΔT near the Néel temperature is around 15 K for any thickness of Tb films. However large thickness effects are found for small values of the magnetic field. For field strength of the order of a few kOe, the thermocaloric efficiency increases significantly for ultrathin (nanomagnetic) films.

  12. Rotating magnetic field induced oscillation of magnetic particles for in vivo mechanical destruction of malignant glioma.

    Science.gov (United States)

    Cheng, Yu; Muroski, Megan E; Petit, Dorothée C M C; Mansell, Rhodri; Vemulkar, Tarun; Morshed, Ramin A; Han, Yu; Balyasnikova, Irina V; Horbinski, Craig M; Huang, Xinlei; Zhang, Lingjiao; Cowburn, Russell P; Lesniak, Maciej S

    2016-02-10

    Magnetic particles that can be precisely controlled under a magnetic field and transduce energy from the applied field open the way for innovative cancer treatment. Although these particles represent an area of active development for drug delivery and magnetic hyperthermia, the in vivo anti-tumor effect under a low-frequency magnetic field using magnetic particles has not yet been demonstrated. To-date, induced cancer cell death via the oscillation of nanoparticles under a low-frequency magnetic field has only been observed in vitro. In this report, we demonstrate the successful use of spin-vortex, disk-shaped permalloy magnetic particles in a low-frequency, rotating magnetic field for the in vitro and in vivo destruction of glioma cells. The internalized nanomagnets align themselves to the plane of the rotating magnetic field, creating a strong mechanical force which damages the cancer cell structure inducing programmed cell death. In vivo, the magnetic field treatment successfully reduces brain tumor size and increases the survival rate of mice bearing intracranial glioma xenografts, without adverse side effects. This study demonstrates a novel approach of controlling magnetic particles for treating malignant glioma that should be applicable to treat a wide range of cancers. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Magnetization oscillations and waves driven by pure spin currents

    Energy Technology Data Exchange (ETDEWEB)

    Demidov, V.E. [Institute for Applied Physics and Center for Nanotechnology, University of Muenster, Corrensstrasse 2-4, 48149 Muenster (Germany); Urazhdin, S. [Department of Physics, Emory University, Atlanta, GA 30322 (United States); Loubens, G. de [SPEC, CEA, CNRS, Université Paris-Saclay, CEA Saclay, 91191 Gif-sur-Yvette (France); Klein, O. [INAC-SPINTEC, CEA/CNRS and Univ. Grenoble Alpes, 38000 Grenoble (France); Cros, V.; Anane, A. [Unité Mixte de Physique CNRS, Thales, Univ. Paris Sud, Université Paris-Saclay, 91767 Palaiseau (France); Demokritov, S.O., E-mail: demokrit@uni-muenster.de [Institute for Applied Physics and Center for Nanotechnology, University of Muenster, Corrensstrasse 2-4, 48149 Muenster (Germany); Institute of Metal Physics, Ural Division of RAS, Yekaterinburg 620041 (Russian Federation)

    2017-02-23

    Recent advances in the studies of pure spin currents–flows of angular momentum (spin) not accompanied by the electric currents–have opened new horizons for the emerging technologies based on the electron’s spin degree of freedom, such as spintronics and magnonics. The main advantage of pure spin current, as compared to the spin-polarized electric current, is the possibility to exert spin transfer torque on the magnetization in thin magnetic films without the electrical current flow through the material. In addition to minimizing Joule heating and electromigration effects, this enables the implementation of spin torque devices based on the low-loss insulating magnetic materials, and offers an unprecedented geometric flexibility. Here we review the recent experimental achievements in investigations of magnetization oscillations excited by pure spin currents in different nanomagnetic systems based on metallic and insulating magnetic materials. We discuss the spectral properties of spin-current nano-oscillators, and relate them to the spatial characteristics of the excited dynamic magnetic modes determined by the spatially-resolved measurements. We also show that these systems support locking of the oscillations to external microwave signals, as well as their mutual synchronization, and can be used as efficient nanoscale sources of propagating spin waves.

  14. Linear field demagnetisation of artificial magnetic square ice

    Directory of Open Access Journals (Sweden)

    Jason Phillip Morgan

    2013-12-01

    Full Text Available We have studied experimentally the states formed in artificial square ice nanomagnet systems following demagnetisation in a rotating in-plane applied magnetic field that reduces to zero in a manner that is linear in time. The final states are found to be controlled via the system's lattice constant, which determines the strength of the magnetostatic interactions between the elements, as well as the field ramping rate. We understand these effects as a requirement that the system undergoes a sufficiently large number of active rotations within the critical field window in which elements may be reversed, such that the interactions are allowed to locally exert their influence if the ground state is to be approached. On the other hand, if quenched disorder is too strong when compared to the interaction strength, any close approach to the ground state is impossible. These results show that it is not necessary for there to be any ac component to the field amplitude that is applied to the system during demagnetisation, which is the method almost exclusively employed in field protocols reported to date. Furthermore, by optimising the parameters of our linear demagnetisation protocol, the largest field-generated ground state domains yet reported are found.

  15. Localized spin-wave modes in a triangular magnetic element studied by micro-focused Brillouin light scattering

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, S.; Kwon, J.-H. [School of Materials Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005 (Korea, Republic of); Grünberg, P. [Grünberg Center for Magnetic Nanomaterials, Gwangju Institute of Science and Technology (GIST), Gwangju 61005 (Korea, Republic of); Cho, B.K., E-mail: chobk@gist.ac.kr [School of Materials Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005 (Korea, Republic of)

    2017-09-01

    Highlights: • Direct evidence of localized mode in a triangular nano-magnet using μ-BLS. • Localized regions are identified by the internal field distribution. • The spatially resolved measurement was performed to obtain 2-D intensity map. • Spin modes in same positions can be distinguish comparing with simulated spectrum. • Localized modes were identified by comparing with the simulated spatial profiles. - Abstract: Localized spin-wave modes, which were thermally excited at a specific position in a triangular magnetic element, were investigated using micro-focused Brillouin light scattering in two saturated states, the buckle and Y-states, with an applied magnetic field of 0.24 T parallel and perpendicular to the basal edge, respectively. The measured frequency spectrum at a specific beam spot position, rather than an integrated spectrum, was analyzed by comparing it with the simulation data at a precisely selected position within the beam spot area. The analyzed results were used to plot a two-dimensional intensity map and simulation spatial profile to verify the validity of the analysis. From the analysis process, two localized spin-wave modes in a triangular magnetic element were successfully identified near the apex region in the buckle state and near the basal edge region in the Y-state.

  16. Remodeling of adipose tissue at experimental diabetes mellitus

    Directory of Open Access Journals (Sweden)

    O. A. Konovalova

    2013-08-01

    Full Text Available Introduction Diabetes mellitus (DM type 1 is chronіc disease whith progressive selective destruction of β- cells pancreatic islets (of Langerhans and whith development of absolute insulin failure. Active immune mechanisms take part in pathogenesis of this disease. Recently many publication appeared which report about the role of adipose tissue. In such way adipose tissue is not only the main metabolic regulator and endocrine organ synthesizing more than 30 regulatory proteins- adipokines, but it is one of the organs of immune system. Dysregulation of adipose tissue leads to morphological restructuring- remodeling of adipocytes, and the development of inflammation of adipose tissue in its turn is integral component of progression of many diseases. The aim of research The aim of this study was to investigate the morphological and functional state of parapancreatic fibre adipocytes in male Wistar rats in experimental diabetes mellitus. Materials and methods The study has been carried out on 20 male Wistar rats with weight 115-135 g. The animals were divided into 2 groups. The control group, which were injected 0,5 ml 0,1 М citrate buffer intraperitoneally (1group. Rats with 7 day experimental streptozotocin-induced diabetes mellitus were in the 2nd group. Adipose tissue was examined on the seventh day. For histological examination sections were colored with haematoxylin and eosin. Images were taken by using a fluorescence microscope PrimoStar(ZEISS,Germany with a computer-assisted video system AxioCam 5c (ZEISS,Germany including the NIH-Image software (NIH Image version 1·46. All statistical analyses were performed using EXCEL MS Office 2010 (Microsoft Corp., USA, STATISTICA 6.0 (Stat-Soft, 2001 software. Results were expressed as mean values ± SEM. Differences were considered statistically significant if the p value was <0.05. Results Injection of streptozotocin to experimental animals led to the development of experimental diabetes mellitus

  17. Effect of experimental ileitis on expression of tlr-2 in lymphfocytes of small intestine

    Directory of Open Access Journals (Sweden)

    A. S. Zherebiatiev

    2013-08-01

    Full Text Available Introduction Crohn’s disease and ulcerative colitis are the main clinical phenotypes of inflammatory bowel disease (IBD. Both forms of IBD can increase the incidence of gastrointestinal and colon cancers, and both ones are associated with significant morbidity and mortality worldwide. In addition, they can begin early in life and persist for long periods. The pathogenesis of IBD is complex and multifactorial. Differential alteration of Toll-like receptor (TLR expression in inflammatory bowel disease was first described 15 years ago. Studies have led to the current concept that TLRs represent key mediators of innate host defense in the intestine, and they are involved in mucosa maintaining as well as commensal homeostasis. Recent findings in diverse murine models of ileitis have helped to reveal the importance of TLR dysfunction mechanisms in IBD pathogenesis. The aim of research The aim of this study was to investigate the effect of acute ileitis on expression intensity of TLR-2 in lymphocytes of small intestine. Materials and methods Male Wistar rats with weight 200–250 g were housed in standard wire-mesh bottom cages at constant temperature of 25°C and 12/12 h light/dark cycles. The rats were given water and standard laboratory diet with no restriction prior to indomethacin injection. A total number of 20 rats were examined, including control group (n = 10. For induction of acute ileitis, rats received one subcutaneous dose of indomethacin (Sigma, 15 mg/kg. Tissue was examined on the fifth day. For histological examination sections were colored with haematoxylin and eosin. The TLR-2+cells were determined using a direct immunofluorescence technique with using monoclonal rat anti-TLR-2 antibodies. Images were taken by using a fluorescence microscope PrimoStar (ZEISS, Germany with a computer-assisted video system AxioCam 5c (ZEISS, Germany including the NIH-Image software (NIH Image version 1·46. All statistical analyses were performed

  18. Avaliação da resistência adesiva e do padrão de descolagem de diferentes sistemas de colagem de braquetes associados à clorexidina Evaluation of the bond strength and debonding pattern of different bracket bonding systems associated with chlorhexidine

    Directory of Open Access Journals (Sweden)

    Jorge Luís de Oliveira Ribeiro

    2008-08-01

    Full Text Available OBJETIVOS: o objetivo deste estudo in vitro foi avaliar a resistência adesiva e o padrão de descolagem de diferentes sistemas de colagem de braquetes (Sistema Transbond XT / 3M-Unitek e Sistema Enlight / Ormco cujos respectivos adesivos foram pré-misturados ao verniz de clorexidina (Cervitec / Ivoclar-Vivadent. METODOLOGIA: a amostra utilizada foi constituída por 60 pré-molares humanos, extraídos por indicações ortodônticas, incluídos em cilindros de PVC e divididos aleatoriamente em quatro grupos: grupo 1 - Sistema Transbond XT conforme prescrito pelo fabricante; grupo 2 - Sistema Transbond XT associado a verniz de clorexidina; grupo 3 - Sistema Enlight conforme prescrito pelo fabricante; grupo 4 - Sistema Enlight associado a verniz de clorexidina. A resistência adesiva foi avaliada pelo teste de cisalhamento na máquina de ensaios universal EMIC (0,5mm/min; o padrão de descolagem foi avaliado, através da lupa estereoscópica STEMI 2000-C / Zeiss (20x, pela observação do Índice de Adesivo Remanescente (IAR na superfície do esmalte dentário, após a descolagem dos braquetes. RESULTADOS: não houve diferença estatisticamente significante (p AIM: The objective of this in vitro study was to evaluate the bond strength and the debonding pattern of different bracket bonding systems (Transbond XT System / 3M-Unitek and Enlight System / Ormco whose respective adhesives were pre-mixed with chlorhexidine varnish (Cervitec / Ivoclar-Vivadent. METHODS: The sample used consisted of sixty human pre-molars extracted for orthodontic purposes, included in PVC cylinder and randomly divided in four experimental groups: group 1 - Transbond XT System according to the manufacturer’s instructions; group 2 - Transbond XT System combined with chlorhexidine varnish; group 3 - Enlight System according to the manufacturer’s instructions; group 4 - Enlight System combined with chlorhexidine varnish. The bond strength evaluation was obtained through

  19. Electron energy loss spectroscopy microanalysis and imaging in the transmission electron microscope: example of biological applications

    International Nuclear Information System (INIS)

    Diociaiuti, Marco

    2005-01-01

    This paper reports original results obtained in our laboratory over the past few years in the application of both electron energy loss spectroscopy (EELS) and electron spectroscopy imaging (ESI) to biological samples, performed in two transmission electron microscopes (TEM) equipped with high-resolution electron filters and spectrometers: a Gatan model 607 single magnetic sector double focusing EEL serial spectrometer attached to a Philips 430 TEM and a Zeiss EM902 Energy Filtering TEM. The primary interest was on the possibility offered by the combined application of these spectroscopic techniques with those offered by the TEM. In particular, the electron beam focusing available in a TEM allowed us to perform EELS and ESI on very small sample volumes, where high-resolution imaging and electron diffraction techniques can provide important structural information. I show that ESI was able to improve TEM performance, due to the reduced chromatic aberration and the possibility of avoiding the sample staining procedure. Finally, the analysis of the oscillating extended energy loss fine structure (EXELFS) beyond the ionization edges characterizing the EELS spectra allowed me, in a manner very similar to the extended X-ray absorption fine structure (EXAFS) analysis of the X-ray absorption spectra, to obtain short-range structural information for such light elements of biological interest as O or Fe. The Philips EM430 (250-300 keV) TEM was used to perform EELS microanalysis on Ca, P, O, Fe, Al and Si. The assessment of the detection limits of this method was obtained working with well-characterized samples containing Ca and P, and mimicking the actual cellular matrix. I applied EELS microanalysis to Ca detection in bone tissue during the mineralization process and to P detection in the cellular membrane of erythrocytes treated with an anti-tumoral drug, demonstrating that the cellular membrane is a drug target. I applied EELS microanalysis and selected area electron

  20. Engineered nano-magnetic iron oxide-urea-activated carbon nanolayer sorbent for potential removal of uranium (VI) from aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Mahmoud, Mohamed E., E-mail: memahmoud10@yahoo.com [Faculty of Sciences, Alexandria University, P.O. Box 426, Ibrahimia, 21321, Alexandria (Egypt); Khalifa, Mohamed A.; El Wakeel, Yasser M.; Header, Mennatllah S. [Faculty of Sciences, Alexandria University, P.O. Box 426, Ibrahimia, 21321, Alexandria (Egypt); Abdel-Fattah, Tarek M. [Applied Research Center Thomas Jefferson National Accelerator Facility, Department of Molecular Biology and Chemistry, Christopher Newport University, Newport News, VA 23606 (United States)

    2017-04-15

    A novel magnetic nanosorbent was designed using chemical grafting of nano-magnetite (Nano-Fe{sub 3}O{sub 4}) with nanolayer of activated carbon (AC) via urea intermediate for the formation of Nano-Fe{sub 3}O{sub 4}-Urea-AC. Characterizing was carried out using FT-IR, SEM, HR-TEM, TGA, point of zero charge (Pzc) and surface area analysis. The designed sorbent maintained its magnetic properties and nanosized structure in the range of 8.7–14.1 nm. The surface area was identified as 389 m{sup 2}/g based on the BET method. Sorption of uranyl ions from aqueous solutions was studied and evaluated in different experimental conditions. Removal of uranyl ions increased with increasing in pH value and the maximum percentage removal was established at pH 5.0. The removal and sorption processes of uranyl ions by Nano-Fe{sub 3}O{sub 4}-Urea-AC sorbent were studied and optimized using the batch technique. The key variables affecting removal of uranyl ions were studied including the effect of the contact time, dosage of Nano-Fe{sub 3}O{sub 4}-Urea-AC sorbent, reaction temperature, initial uranyl ions concentration and interfering anions and cations. - Highlights: •A novel magnetic nanosorbent was designed and synthesized. •Nano-Fe{sub 3}O{sub 4}) was coated with nanolayer of activated carbon. •The particle size of magnetic nanosorbent in the range of 8.65–14.06 nm. •Optimization of experimental controlling factors. •Maximum percentage removal uranyl ions was established at pH 5.0.

  1. Testing EDM of Total Stations

    Directory of Open Access Journals (Sweden)

    Cirbus Ján

    2001-03-01

    Full Text Available The paper is devoted to testing electrooptical distance measuring devices (EDM built in total stations, than can be used for various tasks in the contemporary geodetic works. A rich market offer and availability of these universal measuring systems with satisfying distance range, excellent accuracy and other parameters, make total stations as dominant terrestrial geodetic instruments.For succesfully applying these instruments, above all for relliable distance measurements, the stability of the modulation frequency is the most important pre-condition. In the article, therefore, there are given some methods to verify the modulation frequency stability. In addition, some ways for determining the EDM distance constant and periodical corrections of the phase measuring unit are introduced for 4 types of EDM : LEICA 1700L, TOPCON GTS6A, TOPCON GTS2, C.ZEISS ELTA50. It were also investigated their possibilities for precise distance survey. Values of the determined constants and periodical corrections are presented in Tab. 2.Based on the investigation results of the 4 EDM types and using the values m obtained for different distances S, equations of the a posteriori standard deviations in form : m = (a+b.S were derived too.

  2. Using an electron paramagnetic resonance method for testing motor oils

    Energy Technology Data Exchange (ETDEWEB)

    Krais, S; Tkac, T

    1982-01-01

    Using an ER-9 spectrometer from the Karl Zeiss company, the relative effectiveness is studied of antioxidation additives. Motor oils of the E group, M6AD, 465, M6AD, 466, M6AD 467, 15 W/40, S-3/2 M/4, R-950, which contain the antioxidation additive were tested in Petter AV-1 motors at a temperature of 50 degrees for 120 hours and Petter AVB at a temperature of 90 degrees for 53 hours. To measure the concentration of free radicals of the antioxidation additives one part of 2,2-diphenyl-1-picrylhydrazine (I), which forms stable dimagnetic products with the radicals of the antioxidation additives was introduced into each three parts of the oil. The reduction in the intensity of the signal of I was the measure of the radical concentration. The spectrum was taken for 1 to 2 minutes. The graphs of the dependence of the electron paramagnetic resonance on the test time and the concentration of I are built. The beginning and end of the induction period of oxidation of the oils and the change in the hourly activity of the PP was recorded.

  3. Structure-function correlations using scanning laser polarimetry in primary angle-closure glaucoma and primary open-angle glaucoma.

    Science.gov (United States)

    Lee, Pei-Jung; Liu, Catherine Jui-Ling; Wojciechowski, Robert; Bailey-Wilson, Joan E; Cheng, Ching-Yu

    2010-05-01

    To assess the correlations between retinal nerve fiber layer (RNFL) thickness measured with scanning laser polarimetry and visual field (VF) sensitivity in primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). Prospective, comparative, observational cases series. Fifty patients with POAG and 56 patients with PACG were examined using scanning laser polarimetry with variable corneal compensation (GDx VCC; Laser Diagnostic Technologies, Inc.) and Humphrey VF analyzer (Carl Zeiss Meditec, Inc.) between August 2005 and July 2006 at Taipei Veterans General Hospital. Correlations between RNFL thickness and VF sensitivity, expressed as mean sensitivity in both decibel and 1/Lambert scales, were estimated by the Spearman rank correlation coefficient (r(s)) and multivariate median regression models (pseudo R(2)). The correlations were determined globally and for 6 RNFL sectors and their corresponding VF regions. The correlation between RNFL thickness and mean sensitivity (in decibels) was weaker in the PACG group (r(s) = 0.38; P = .004; pseudo R(2) = 0.17) than in the POAG group (r(s) = 0.51; P polarimetry. Compared with eyes with POAG, fewer RNFL sectors have significant structure-function correlations in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  4. Scanning electron microscopy and X-ray energy dispersive spectroscopy - useful tools in the analysis of pharmaceutical products

    Science.gov (United States)

    Sarecka-Hujar, Beata; Balwierz, Radoslaw; Ostrozka-Cieslik, Aneta; Dyja, Renata; Lukowiec, Dariusz; Jankowski, Andrzej

    2017-11-01

    The quality of the drug, its purity and identification of degradation products provide the highest quality of pharmaceutical products. The energy dispersive spectroscopy (EDS) method analyses the percentage of each element form as well as their distribution, and morphological characteristics of the drug form. We analysed the usefulness of EDS method in testing orally disintegrating tablets (ODT) with trimetazidine hydrochloride with high resolution scanning electron microscopy (SEM, SUPRA25 Carl Zeiss company) with spectrophotometer equipped with an X-ray energy dispersion (EDAX Company). The samples of the analysed tablets were imaged after applying conductive layers of gold on their surface. In the EDS analysis the compositions of each sample of the obtained tablets were observed to be virtually identical. The differences in the content of carbon and oxygen came from differences in the composition of particular tablets. The presence of gold in the composition resulted from the sputtering the surface of tablets with gold during the analysis. Knowing the composition of the tablet, SEM-EDS method helps to locate and identify the impurities and degradation products of the compounds, leading to a better understanding of the mechanisms of their formation.

  5. Prevalence of Diabetic retinopathy in Kashmir, India - A hospital based study

    Directory of Open Access Journals (Sweden)

    Tariq Qureshi

    2013-03-01

    Full Text Available Objective To assess the prevalence of diabetic retinopathy among Kashmiri population. Material and Method In a cross-sectional hospital based study, 500 patients with established diabetes who attended eye OPD at Govt Medical College Srinagar were evaluated for the presence or absence of retinopathy. Relevant clinical examination was done and the findings were recorded at one point of time. No follow-up findings of the patients were included in this study. Direct Ophthalmoscope (Heinzand slit lamp bio-microscope (Zeiss were used for examination. Statistical package for Social Sciences (SPSS was used for statistical analysis. p60 yrs of age and 49 patients (36.2% were between 40-68 yrs of age. 33 (24.5% were males and 102 (75.5% were females. 30 patients (12.8% with diabetes of = 15 yr. Mild DR was present in 67 (37.4% patients, moderate to severe DR in 46 (9.2% patients, proliferative DR in 5(1% patients and diabetic maculopathy in 17(3.4%patients. Patients who were managed with insulin, either alone or with oral hypoglycemic drugs, had more prevalence of DR. Conclusion The present study concluded that DR is highly prevalent in this part

  6. Inter-Rater Reliability of Cyclotorsion Measurements Using Fundus Photography.

    Science.gov (United States)

    Dysli, Muriel; Kanku, Madeleine; Traber, Ghislaine L

    2018-04-01

    The foveo-papillary angle (FPA) on fundus photographs is the accepted standard for the measurement of ocular cyclotorsion. We assessed the inter-rater reliability of this method in healthy subjects and in patients with trochlear nerve palsies. In this methodological study, fundus photographs of healthy subjects and of patients with trochlear nerve palsies were made with a fundus camera (Zeiss Fundus Camera FF 450 plus, Jena, Germany). Three independent observers measured the FPA on the fundus photographs of all subjects in synedra View (synedra View 16, Version 16.0.0.11, Innsbruck, Austria). One hundred and four eyes of 52 subjects (26 healthy controls and 26 patients) were assessed. The mean FPA of the healthy controls was 5.80 degrees (°) [± 0.44 standard error of the mean (SEM)] compared to 11.55° (± 0.80 SEM) for patients with trochlear nerve palsies. The inter-rater reliability of all measured FPAs showed an intraclass correlation coefficient (ICC) of 0.98 (95% CI 0.97 - 0.98). The inter-rater reliability of objective cyclotorsion measurements using fundus photographs was very high. Georg Thieme Verlag KG Stuttgart · New York.

  7. Optimization of hole generation in Ti/CFRP stacks

    Science.gov (United States)

    Ivanov, Y. N.; Pashkov, A. E.; Chashhin, N. S.

    2018-03-01

    The article aims to describe methods for improving the surface quality and hole accuracy in Ti/CFRP stacks by optimizing cutting methods and drill geometry. The research is based on the fundamentals of machine building, theory of probability, mathematical statistics, and experiment planning and manufacturing process optimization theories. Statistical processing of experiment data was carried out by means of Statistica 6 and Microsoft Excel 2010. Surface geometry in Ti stacks was analyzed using a Taylor Hobson Form Talysurf i200 Series Profilometer, and in CFRP stacks - using a Bruker ContourGT-Kl Optical Microscope. Hole shapes and sizes were analyzed using a Carl Zeiss CONTURA G2 Measuring machine, temperatures in cutting zones were recorded with a FLIR SC7000 Series Infrared Camera. Models of multivariate analysis of variance were developed. They show effects of drilling modes on surface quality and accuracy of holes in Ti/CFRP stacks. The task of multicriteria drilling process optimization was solved. Optimal cutting technologies which improve performance were developed. Methods for assessing thermal tool and material expansion effects on the accuracy of holes in Ti/CFRP/Ti stacks were developed.

  8. Influence of Magnetite Nanoparticles on the Dielectric Properties of Metal Oxide/Polymer Nanocomposites Based on Polypropylene

    Science.gov (United States)

    Maharramov, A. A.; Ramazanov, M. A.; Di Palma, Luca; Shirinova, H. A.; Hajiyeva, F. V.

    2018-01-01

    Structure and dielectric properties of polymer nanocomposites based on isotactic polypropylene and iron oxide (Fe3O4) nanoparticles are studied. Distribution of magnetite nanoparticles in a polymer matrix was studied by scanning electron microscopy (SEM, Carl Zeiss). Dielectric properties of nanocomposites were examined by means of E7-21 impedance spectrometer in the frequency range of 102-106 Hz and temperature interval of 298-433 K. The frequency and temperature dependences of the dielectric permittivity ɛ, as well as the temperature dependence of log (ρ) were constructed. It is shown that introduction of the magnetite (Fe3O4) nanoparticles into a polypropylene matrix increases the dielectric permittivity of nanocomposites. An increase in the dielectric permittivity is explained by the increase in the polarization ability of nanocomposites. It is found that a decrease in the specific resistance with increasing temperature up to 318 K is associated with an increase in the ionic conductivity of nanocomposites. An increase in the resistance at temperatures higher than 358 K is due to the destruction of the crystalline phase of the polymer, as a result of which the distance between the Fe3O4 nanoparticles increases.

  9. APA/APAGS Award for Distinguished Graduate Student in Professional Psychology.

    Science.gov (United States)

    2016-11-01

    The APA/APAGS Award for Distinguished Graduate Student in Professional Psychology is awarded on an annual basis by the APA Board of Professional Affairs (BPA) and the American Psychological Association of Graduate Students (APAGS) to a graduate student who has demonstrated outstanding practice and application of psychology. A qualified candidate must demonstrate exemplary performance in working with an underserved population in an applied setting or have developed an innovative method for delivering health services to an underserved population. The 2016 recipient of the APA/APAGS Award for Distinguished Graduate Student in Professional Psychology was selected by the 2015 Board of Professional Affairs (BPA) and the 2015 APAGS Scholarship and Awards Selection Committee. Members of the 2015 BPA were Patricia Arredondo, EdD; Helen L. Coons, PhD, ABPP; Vickie Mays, PhD, MSPH; Linda A. Reddy, PhD; Lois O. Condi, PhD; Antonette M. Zeiss, PhD; Timothy A. Cavell, PhD; Robert T. Kinscherff, PhD, JD; and Jared L. Skillings, PhD, ABPP. Members of the 2015 APAGS Scholarship and Awards Selection Committee were Emily Voelkel, PhD; Blaire Schembari; and Yolanda Perkins-Volk. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  10. Effect of bleaching on color change and surface topography of composite restorations.

    Science.gov (United States)

    Pruthi, Gunjan; Jain, Veena; Kandpal, H C; Mathur, Vijay Prakash; Shah, Naseem

    2010-01-01

    This study was conducted to determine the effect of 15% carbamide peroxide bleaching agent on color change and surface topography of different composite veneering materials (Filtek Z350 (3M ESPE), Esthet X (Dentsply India), and Admira (Voco, Germany). Methods. 30 samples were fabricated for evaluation of color change using CIELAB color system and Gonioreflectometer (GK 311/M, ZEISS). 45 disc-shaped specimens were made for evaluation of surface topography after bleaching (Nupro White Gold; Dentsply) using SEM. Statistical analysis. One way ANOVA and Multiple comparison tests were used to analyze the data. Statistical significance was declared if the P value was .05 or less. Results and conclusion. All the specimens showed significant discoloration (ΔE > 3.3) after their immersion in solutions representing food and beverages. The total color change after bleaching as compared to baseline color was significant in Filtek Z350 (P = .000) and Esthet X (P = .002), while it was insignificant for Admira (P = .18). Esthet X showed maximum surface roughness followed by Admira and Filtek Z350. Bleaching was effective in reducing the discoloration to a clinically acceptable value in all the three groups (ΔE < 3.3).

  11. Effect of Bleaching on Color Change and Surface Topography of Composite Restorations

    Directory of Open Access Journals (Sweden)

    Gunjan Pruthi

    2010-01-01

    Full Text Available This study was conducted to determine the effect of 15% carbamide peroxide bleaching agent on color change and surface topography of different composite veneering materials (Filtek Z350 (3M ESPE, Esthet X (Dentsply India, and Admira (Voco, Germany. Methods. 30 samples were fabricated for evaluation of color change using CIELAB color system and Gonioreflectometer (GK 311/M, ZEISS. 45 disc-shaped specimens were made for evaluation of surface topography after bleaching (Nupro White Gold; Dentsply using SEM. Statistical analysis. One way ANOVA and Multiple comparison tests were used to analyze the data. Statistical significance was declared if the P value was .05 or less. Results and conclusion. All the specimens showed significant discoloration (ΔE>3.3 after their immersion in solutions representing food and beverages. The total color change after bleaching as compared to baseline color was significant in Filtek Z350 (P=.000 and Esthet X (P=.002, while it was insignificant for Admira (P=.18. Esthet X showed maximum surface roughness followed by Admira and Filtek Z350. Bleaching was effective in reducing the discoloration to a clinically acceptable value in all the three groups (ΔE<3.3.

  12. Optical coherence tomography in anterior segment imaging

    Science.gov (United States)

    Kalev-Landoy, Maya; Day, Alexander C.; Cordeiro, M. Francesca; Migdal, Clive

    2008-01-01

    Purpose To evaluate the ability of optical coherence tomography (OCT), designed primarily to image the posterior segment, to visualize the anterior chamber angle (ACA) in patients with different angle configurations. Methods In a prospective observational study, the anterior segments of 26 eyes of 26 patients were imaged using the Zeiss Stratus OCT, model 3000. Imaging of the anterior segment was achieved by adjusting the focusing control on the Stratus OCT. A total of 16 patients had abnormal angle configurations including narrow or closed angles and plateau irides, and 10 had normal angle configurations as determined by prior full ophthalmic examination, including slit-lamp biomicroscopy and gonioscopy. Results In all cases, OCT provided high-resolution information regarding iris configuration. The ACA itself was clearly visualized in patients with narrow or closed angles, but not in patients with open angles. Conclusions Stratus OCT offers a non-contact, convenient and rapid method of assessing the configuration of the anterior chamber. Despite its limitations, it may be of help during the routine clinical assessment and treatment of patients with glaucoma, particularly when gonioscopy is not possible or difficult to interpret. PMID:17355288

  13. Synthesis and structural characterization of bulk Sb2Te3 single crystal

    Science.gov (United States)

    Sultana, Rabia; Gahtori, Bhasker; Meena, R. S.; Awana, V. P. S.

    2018-05-01

    We report the growth and characterization of bulk Sb2Te3 single crystal synthesized by the self flux method via solid state reaction route from high temperature melt (850˚C) and slow cooling (2˚C/hour) of constituent elements. The single crystal X-ray diffraction pattern showed the 00l alignment and the high crystalline nature of the resultant sample. The rietveld fitted room temperature powder XRD revealed the phase purity and rhombohedral structure of the synthesized crystal. The formation and analysis of unit cell structure further verified the rhombohedral structure composed of three quintuple layers stacked one over the other. The SEM image showed the layered directional growth of the synthesized crystal carried out using the ZEISS-EVOMA-10 scanning electron microscope The electrical resistivity measurement was carried out using the conventional four-probe method on a quantum design Physical Property Measurement System (PPMS). The temperature dependent electrical resistivity plot for studied Sb2Te3 single crystal depicts metallic behaviour in the absence of any applied magnetic field. The synthesis as well as the structural characterization of as grown Sb2Te3 single crystal is reported and discussed in the present letter.

  14. Carcinoma de glándulas sebáceas limitado a conjuntiva bulbar

    Directory of Open Access Journals (Sweden)

    Manuel Fernando Buitrago-Torrado

    Full Text Available El carcinoma de glándulas sebáceas es un tumor infrecuente que puede desarrollarse a partir de cualquier glándula sebácea en la piel. El 75 % de las veces es de origen ocular y afecta principalmente las glándulas de Zeiss, Meibomio y de la carúncula. Se caracteriza por un comportamiento agresivo, con alta probabilidad de invasión a piel, conjuntiva y córnea. Sin embargo, el compromiso de la conjuntiva como localización primaria es raro. Se presenta un caso con diagnóstico de carcinoma sebáceo de patrón nodular primario de la conjuntiva bulbar, atendido en el Hospital Universitario de Santander durante los años 2014-2016. El propósito del presente estudio es dar a conocer el caso de una patología infrecuente con pocos casos reportados en la literatura, enfatizar su importancia dentro de los diagnósticos diferenciales de masas en la conjuntiva y del estudio histopatológico como método para obtener un diagnóstico definitivo y realizar un abordaje temprano.

  15. Modified surface based on magnetic nanocomposite of dithiooxamide/Fe{sub 3}O{sub 4} as a sorbent for preconcentration and determination of trace amounts of copper

    Energy Technology Data Exchange (ETDEWEB)

    Mirabi, Ali, E-mail: mirabi2012@yahoo.com [Department of Chemistry, Qaemshahr Branch, Islamic Azad University, Qaemshahr (Iran, Islamic Republic of); Shokuhi Rad, Ali, E-mail: a.shokuhi@gmail.com [Department of Chemical Engineering, Qaemshahr Branch, Islamic Azad University, Qaemshahr (Iran, Islamic Republic of); Khodadad, Hadiseh [Department of Chemistry, Qaemshahr Branch, Islamic Azad University, Qaemshahr (Iran, Islamic Republic of)

    2015-09-01

    Magnetic nanocomposites surface (MNCS) which has anionic surfactant sodium dodecyl sulfate (SDS) coating and has undergone dithiooxamide treatment as the sorbent could be an easy and useful method to extract and make a pre-concentrated in detecting the copper ions before they are determined via the flame atomic absorption spectrometry (FAAS). The influences of the experimental parameters such as the pH of the sample, the type and concentration of the eluent, dithiooxamide concentration and volume, amount of sorbent and the interactions of ions with respect to the copper ion detection have been studied. The calibration graph was linear in the range of 2–600 ng ml{sup −1} with detection limit of 0.2 ng ml{sup −1}. Relative standard deviation (RSD) for 6 replicate measurements was 1.8%. This method of detection has been applied to the determination of Cu ions at levels in real samples such as wheat flour, tomatoes, potatoes, red beans, oat, tap water, river water and sea water with satisfactory results. - Highlights: • Fe{sub 3}O{sub 4} nano-magnetic improved by SDS/dithiooxamide. • It can be used in both the pre-concentration function and detecting of Cu ions. • This modified surface shows high adsorptive characteristics. • This procedure is relatively simple, fast and imposes less test analysis expenses.

  16. Direct surface magnetometry with photoemission magnetic x-ray dichroism

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, J.G.; Goodman, K.W. [Lawrence Berkeley National Lab., CA (United States); Schumann, F.O. [Pennsylvania State Univ., University Park, PA (United States)] [and others

    1997-04-01

    Element specific surface magnetometry remains a central goal of synchrotron radiation based studies of nanomagnetic structures. One appealing possibility is the combination of x-ray absorption dichroism measurements and the theoretical framework provided by the {open_quotes}sum rules.{close_quotes} Unfortunately, sum rule analysis are hampered by several limitations including delocalization of the final state, multi-electronic phenomena and the presence of surface dipoles. An alternative experiment, Magnetic X-Ray Dichroism in Photoelectron Spectroscopy, holds out promise based upon its elemental specificity, surface sensitivity and high resolution. Computational simulations by Tamura et al. demonstrated the relationship between exchange and spin orbit splittings and experimental data of linear and circular dichroisms. Now the authors have developed an analytical framework which allows for the direct extraction of core level exchange splittings from circular and linear dichroic photoemission data. By extending a model initially proposed by Venus, it is possible to show a linear relation between normalized dichroism peaks in the experimental data and the underlying exchange splitting. Since it is reasonable to expect that exchange splittings and magnetic moments track together, this measurement thus becomes a powerful new tool for direct surface magnetometry, without recourse to time consuming and difficult spectral simulations. The theoretical derivation will be supported by high resolution linear and circular dichroism data collected at the Spectromicroscopy Facility of the Advanced Light Source.

  17. Building Composite Fe-Mn Oxide Flower-Like Nanostructures: A Detailed Magnetic Study

    KAUST Repository

    Zuddas, Efisio; Lentijo Mozo, Sergio; Casu, Alberto; Deiana, Davide; Falqui, Andrea

    2017-01-01

    Here we show that it’s possible to produce different magnetic core-multiple shells heterostructures from monodispersed iron oxide spherical magnetic seeds by finely controlling the amount of a manganese precursor and using in a smart and simple way a cation exchange synthetic approach. In particular, by increasing the amount of precursor we were able to produce nanostructures ranging from Fe3O4/Mn-ferrite core/single shell nanospheres to larger, flower-like Fe3O4/Mn-ferrite/Mn3O4 core-double shell nanoparticles. We first demonstrate how the formation of the initial thin manganese-ferrite shell determines a dramatic reduction of the superficial disorder in the starting iron oxide, bringing to nanomagnets with lower hardness. Then, the growth of the second and most external manganese oxide shell causes the magnetical hardening of the heterostructures, while its magnetic exchange coupling with the rest of the heterostructure can be antiferromagentic or ferromagnetic, depending on the strength of the applied external magnetic field. This response is similar to that of an iron oxide-manganese oxide core-shell system but differs from what observed in multiple-shell heterostructures. Finally, we report as the most external shell becomes magnetically irrelevant above the ferrimagnetic-paramagnetic transition of the manganese oxide and the resulting magnetic behavior of the flower-like structures is then studied in-depth.

  18. Modified surface based on magnetic nanocomposite of dithiooxamide/Fe3O4 as a sorbent for preconcentration and determination of trace amounts of copper

    International Nuclear Information System (INIS)

    Mirabi, Ali; Shokuhi Rad, Ali; Khodadad, Hadiseh

    2015-01-01

    Magnetic nanocomposites surface (MNCS) which has anionic surfactant sodium dodecyl sulfate (SDS) coating and has undergone dithiooxamide treatment as the sorbent could be an easy and useful method to extract and make a pre-concentrated in detecting the copper ions before they are determined via the flame atomic absorption spectrometry (FAAS). The influences of the experimental parameters such as the pH of the sample, the type and concentration of the eluent, dithiooxamide concentration and volume, amount of sorbent and the interactions of ions with respect to the copper ion detection have been studied. The calibration graph was linear in the range of 2–600 ng ml −1 with detection limit of 0.2 ng ml −1 . Relative standard deviation (RSD) for 6 replicate measurements was 1.8%. This method of detection has been applied to the determination of Cu ions at levels in real samples such as wheat flour, tomatoes, potatoes, red beans, oat, tap water, river water and sea water with satisfactory results. - Highlights: • Fe 3 O 4 nano-magnetic improved by SDS/dithiooxamide. • It can be used in both the pre-concentration function and detecting of Cu ions. • This modified surface shows high adsorptive characteristics. • This procedure is relatively simple, fast and imposes less test analysis expenses

  19. Les tüchlein et les succhi d’erba 

    Directory of Open Access Journals (Sweden)

    Aurélie Minet

    2010-11-01

    Full Text Available Les tüchlein et les succhi d’erba sont deux techniques de peinture sur toile qui suscitent la curiosité et le questionnement du grand public comme des spécialistes du patrimoine artistique. Dans le cadre d’un mémoire de fin d’études réalisé en 2009, ces deux techniques ont été confrontées du point de vue sémantique, technique et technologique. Une proposition de traitement à l’aide d’« éponges nanomagnétiques » fut également étudiée. Cet article présente la méthodologie utilisée lors de cette recherche et réalise une synthèse des résultats obtenus par les différentes investigations et expérimentations.The tüchlein and the succhi d’erba are two canvas painting techniques which have promoted great interest not only from the general public but also from expert specialized in artistic heritage. In 2009, the semantic, the technical and technological skills of the two techniques were examined. A suggested treatment for this type of work of art with “nanomagnetical sponges” was also studied. This article shows the methodology used in this research and combines the results obtained by the different experiments and investigations.

  20. Probing spin dynamics and quantum relaxation in Li Y0.998 Ho0.002 F4 via 19F NMR

    Science.gov (United States)

    Graf, M. J.; Lascialfari, A.; Borsa, F.; Tkachuk, A. M.; Barbara, B.

    2006-01-01

    We report measurements of F19 nuclear spin-lattice relaxation 1/T1 as a function of temperature and external magnetic field in a LiY0.998Ho0.002F4 single crystal, a single-ion magnet exhibiting interesting quantum effects. The F19 1/T1 is found to depend on the coupling with the diluted rare-earth (RE) moments, making it an effective probe of the rare-earth spin dynamics. The results for 1/T1 show a behavior similar to that observed in molecular nanomagnets, a result which we attribute to the discreteness of the energy levels in both cases. At intermediate temperatures the lifetime broadening of the crystal field split RE magnetic levels follows a T3 power law. At low temperature the field dependence of 1/T1 shows peaks in correspondence to the critical magnetic fields for energy level crossings (LC). A key result of this study is that the broadening of the levels at LC is found to become extremely small at low temperatures, about 1.7mT , a value which is comparable to the weak dipolar fields at the RE lattice positions. Thus, unlike the molecular magnets, decoherence effects are strongly suppressed, and it may be possible to measure directly the level repulsions at avoided level crossings.