WorldWideScience

Sample records for improved reconstruction quality

  1. Improvement of Quality of Reconstructed Images in Multi-Frame Fresnel Digital Holography

    International Nuclear Information System (INIS)

    Xiao-Wei, Lu; Jing-Zhen, Li; Hong-Yi, Chen

    2010-01-01

    A modified reconstruction algorithm to improve the quality of reconstructed images of multi-frame Fresnel digital holography is presented. When the reference beams are plane or spherical waves with azimuth encoding, by introducing two spherical wave factors, images can be reconstructed with only one time Fourier transform. In numerical simulation, this algorithm could simplify the reconstruction process and improve the signal-to-noise ratio of the reconstructed images. In single-frame reconstruction experiments, the accurate reconstructed image is obtained with this simplified algorithm

  2. Statistical iterative reconstruction to improve image quality for digital breast tomosynthesis

    International Nuclear Information System (INIS)

    Xu, Shiyu; Chen, Ying; Lu, Jianping; Zhou, Otto

    2015-01-01

    Purpose: Digital breast tomosynthesis (DBT) is a novel modality with the potential to improve early detection of breast cancer by providing three-dimensional (3D) imaging with a low radiation dose. 3D image reconstruction presents some challenges: cone-beam and flat-panel geometry, and highly incomplete sampling. A promising means to overcome these challenges is statistical iterative reconstruction (IR), since it provides the flexibility of accurate physics modeling and a general description of system geometry. The authors’ goal was to develop techniques for applying statistical IR to tomosynthesis imaging data. Methods: These techniques include the following: a physics model with a local voxel-pair based prior with flexible parameters to fine-tune image quality; a precomputed parameter λ in the prior, to remove data dependence and to achieve a uniform resolution property; an effective ray-driven technique to compute the forward and backprojection; and an oversampled, ray-driven method to perform high resolution reconstruction with a practical region-of-interest technique. To assess the performance of these techniques, the authors acquired phantom data on the stationary DBT prototype system. To solve the estimation problem, the authors proposed an optimization-transfer based algorithm framework that potentially allows fewer iterations to achieve an acceptably converged reconstruction. Results: IR improved the detectability of low-contrast and small microcalcifications, reduced cross-plane artifacts, improved spatial resolution, and lowered noise in reconstructed images. Conclusions: Although the computational load remains a significant challenge for practical development, the superior image quality provided by statistical IR, combined with advancing computational techniques, may bring benefits to screening, diagnostics, and intraoperative imaging in clinical applications

  3. Statistical iterative reconstruction to improve image quality for digital breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Shiyu, E-mail: shiyu.xu@gmail.com; Chen, Ying, E-mail: adachen@siu.edu [Department of Electrical and Computer Engineering, Southern Illinois University Carbondale, Carbondale, Illinois 62901 (United States); Lu, Jianping; Zhou, Otto [Department of Physics and Astronomy and Curriculum in Applied Sciences and Engineering, University of North Carolina Chapel Hill, Chapel Hill, North Carolina 27599 (United States)

    2015-09-15

    Purpose: Digital breast tomosynthesis (DBT) is a novel modality with the potential to improve early detection of breast cancer by providing three-dimensional (3D) imaging with a low radiation dose. 3D image reconstruction presents some challenges: cone-beam and flat-panel geometry, and highly incomplete sampling. A promising means to overcome these challenges is statistical iterative reconstruction (IR), since it provides the flexibility of accurate physics modeling and a general description of system geometry. The authors’ goal was to develop techniques for applying statistical IR to tomosynthesis imaging data. Methods: These techniques include the following: a physics model with a local voxel-pair based prior with flexible parameters to fine-tune image quality; a precomputed parameter λ in the prior, to remove data dependence and to achieve a uniform resolution property; an effective ray-driven technique to compute the forward and backprojection; and an oversampled, ray-driven method to perform high resolution reconstruction with a practical region-of-interest technique. To assess the performance of these techniques, the authors acquired phantom data on the stationary DBT prototype system. To solve the estimation problem, the authors proposed an optimization-transfer based algorithm framework that potentially allows fewer iterations to achieve an acceptably converged reconstruction. Results: IR improved the detectability of low-contrast and small microcalcifications, reduced cross-plane artifacts, improved spatial resolution, and lowered noise in reconstructed images. Conclusions: Although the computational load remains a significant challenge for practical development, the superior image quality provided by statistical IR, combined with advancing computational techniques, may bring benefits to screening, diagnostics, and intraoperative imaging in clinical applications.

  4. Adaptive statistical iterative reconstruction for volume-rendered computed tomography portovenography. Improvement of image quality

    International Nuclear Information System (INIS)

    Matsuda, Izuru; Hanaoka, Shohei; Akahane, Masaaki

    2010-01-01

    Adaptive statistical iterative reconstruction (ASIR) is a reconstruction technique for computed tomography (CT) that reduces image noise. The purpose of our study was to investigate whether ASIR improves the quality of volume-rendered (VR) CT portovenography. Institutional review board approval, with waived consent, was obtained. A total of 19 patients (12 men, 7 women; mean age 69.0 years; range 25-82 years) suspected of having liver lesions underwent three-phase enhanced CT. VR image sets were prepared with both the conventional method and ASIR. The required time to make VR images was recorded. Two radiologists performed independent qualitative evaluations of the image sets. The Wilcoxon signed-rank test was used for statistical analysis. Contrast-noise ratios (CNRs) of the portal and hepatic vein were also evaluated. Overall image quality was significantly improved by ASIR (P<0.0001 and P=0.0155 for each radiologist). ASIR enhanced CNRs of the portal and hepatic vein significantly (P<0.0001). The time required to create VR images was significantly shorter with ASIR (84.7 vs. 117.1 s; P=0.014). ASIR enhances CNRs and improves image quality in VR CT portovenography. It also shortens the time required to create liver VR CT portovenographs. (author)

  5. Enhancing Tomo-PIV reconstruction quality by reducing ghost particles

    International Nuclear Information System (INIS)

    De Silva, C M; Baidya, R; Marusic, I

    2013-01-01

    A technique to enhance the reconstruction quality and consequently the accuracy of the velocity vector field obtained in Tomo-PIV experiments is presented here. The methodology involves detecting and eliminating spurious outliers in the reconstructed intensity field (ghost particles). A simulacrum matching-based reconstruction enhancement (SMRE) technique is proposed, which utilizes the characteristic shape and size of actual particles to remove ghost particles in the reconstructed intensity field. An assessment of SMRE is performed by a quantitative comparison of Tomo-PIV simulation results and DNS data, together with a comparison to Tomo-PIV experimental data measured in a turbulent channel flow at a matched Reynolds number (Re τ = 937) to the DNS study. For the simulation data, a comparative study is performed on the reconstruction quality based on an ideal reconstruction determined from known particle positions. The results suggest that a significant improvement in the reconstruction quality and flow statistics is achievable at typical seeding densities used in Tomo-PIV experiments. This improvement is further amplified at higher seeding densities, enabling the use of up to twice the typical seeding densities currently used in Tomo-PIV experiments. A reduction of spurious vectors present in the velocity field is also observed based on a median outlier detection criterion. The application of SMRE to Tomo-PIV experimental data shows an improvement in flow statistics, comparable to the improvement seen in simulations. Finally, due to the non-iterative nature of SMRE, the increase in processing time is marginal since only a single pass of the reconstruction algorithm is required. (paper)

  6. Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction

    International Nuclear Information System (INIS)

    Hosch, Waldemar; Stiller, Wolfram; Mueller, Dirk; Gitsioudis, Gitsios; Welzel, Johanna; Dadrich, Monika; Buss, Sebastian J.; Giannitsis, Evangelos; Kauczor, Hans U.; Katus, Hugo A.; Korosoglou, Grigorios

    2012-01-01

    Purpose: To assess the impact of body mass index (BMI)-adapted protocols and iterative reconstruction algorithms (iDose) on patient radiation exposure and image quality in patients undergoing prospective ECG-triggered 256-slice coronary computed tomography angiography (CCTA). Methods: Image quality and radiation exposure were systematically analyzed in 100 patients. 60 Patients underwent prospective ECG-triggered CCTA using a non-tailored protocol and served as a ‘control’ group (Group 1: 120 kV, 200 mA s). 40 Consecutive patients with suspected coronary artery disease (CAD) underwent prospective CCTA, using BMI-adapted tube voltage and standard (Group 2: 100/120 kV, 100–200 mA s) versus reduced tube current (Group 3: 100/120 kV, 75–150 mA s). Iterative reconstructions were provided with different iDose levels and were compared to filtered back projection (FBP) reconstructions. Image quality was assessed in consensus of 2 experienced observers and using a 5-grade scale (1 = best to 5 = worse), and signal- and contrast-to-noise ratios (SNR and CNR) were quantified. Results: CCTA was performed without adverse events in all patients (n = 100, heart rate of 47–87 bpm and BMI of 19–38 kg/m 2 ). Patients examined using the non-tailored protocol in Group 1 had the highest radiation exposure (3.2 ± 0.4 mSv), followed by Group 2 (1.7 ± 0.7 mSv) and Group 3 (1.2 ± 0.6 mSv) (radiation savings of 47% and 63%, respectively, p < 0.001). Iterative reconstructions provided increased SNR and CNR, particularly when higher iDose level 5 was applied with Multi-Frequency reconstruction (iDose5 MFR) (14.1 ± 4.6 versus 21.2 ± 7.3 for SNR and 12.0 ± 4.2 versus 18.1 ± 6.6 for CNR, for FBP versus iDose5 MFR, respectively, p < 0.001). The combination of BMI adaptation with iterative reconstruction reduced radiation exposure and simultaneously improved image quality (subjective image quality of 1.4 ± 0.4 versus 1.9 ± 0.5 for Group 2 reconstructed using iDose5 MFR versus

  7. The optimal monochromatic spectral computed tomographic imaging plus adaptive statistical iterative reconstruction algorithm can improve the superior mesenteric vessel image quality

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Xiao-Ping; Zuo, Zi-Wei; Xu, Ying-Jin; Wang, Jia-Ning [CT/MRI room, Affiliated Hospital of Hebei University, Baoding, Hebei, 071000 (China); Liu, Huai-Jun, E-mail: hebeiliu@outlook.com [Department of Medical Imaging, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050000 (China); Liang, Guang-Lu [CT/MRI room, Affiliated Hospital of Hebei University, Baoding, Hebei, 071000 (China); Gao, Bu-Lang, E-mail: browngao@163.com [Department of Medical Research, Shijiazhuang First Hospital, Shijiazhuang, Hebei, 050011 (China)

    2017-04-15

    Objective: To investigate the effect of the optimal monochromatic spectral computed tomography (CT) plus adaptive statistical iterative reconstruction on the improvement of the image quality of the superior mesenteric artery and vein. Materials and methods: The gemstone spectral CT angiographic data of 25 patients were reconstructed in the following three groups: 70 KeV, the optimal monochromatic imaging, and the optimal monochromatic plus 40%iterative reconstruction mode. The CT value, image noises (IN), background CT value and noises, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and image scores of the vessels and surrounding tissues were analyzed. Results: In the 70 KeV, the optimal monochromatic and the optimal monochromatic images plus 40% iterative reconstruction group, the mean scores of image quality were 3.86, 4.24 and 4.25 for the superior mesenteric artery and 3.46, 3.78 and 3.81 for the superior mesenteric vein, respectively. The image quality scores for the optimal monochromatic and the optimal monochromatic plus 40% iterative reconstruction groups were significantly greater than for the 70 KeV group (P < 0.05). The vascular CT value, image noise, background noise, CNR and SNR were significantly (P < 0.001) greater in the optimal monochromatic and the optimal monochromatic images plus 40% iterative reconstruction group than in the 70 KeV group. The optimal monochromatic plus 40% iterative reconstruction group had significantly (P < 0.05) lower image and background noise but higher CNR and SNR than the other two groups. Conclusion: The optimal monochromatic imaging combined with 40% iterative reconstruction using low-contrast agent dosage and low injection rate can significantly improve the image quality of the superior mesenteric artery and vein.

  8. Color quality improvement of reconstructed images in color digital holography using speckle method and spectral estimation

    Science.gov (United States)

    Funamizu, Hideki; Onodera, Yusei; Aizu, Yoshihisa

    2018-05-01

    In this study, we report color quality improvement of reconstructed images in color digital holography using the speckle method and the spectral estimation. In this technique, an object is illuminated by a speckle field and then an object wave is produced, while a plane wave is used as a reference wave. For three wavelengths, the interference patterns of two coherent waves are recorded as digital holograms on an image sensor. Speckle fields are changed by moving a ground glass plate in an in-plane direction, and a number of holograms are acquired to average the reconstructed images. After the averaging process of images reconstructed from multiple holograms, we use the Wiener estimation method for obtaining spectral transmittance curves in reconstructed images. The color reproducibility in this method is demonstrated and evaluated using a Macbeth color chart film and staining cells of onion.

  9. SU-E-I-93: Improved Imaging Quality for Multislice Helical CT Via Sparsity Regularized Iterative Image Reconstruction Method Based On Tensor Framelet

    International Nuclear Information System (INIS)

    Nam, H; Guo, M; Lee, K; Li, R; Xing, L; Gao, H

    2014-01-01

    Purpose: Inspired by compressive sensing, sparsity regularized iterative reconstruction method has been extensively studied. However, its utility pertinent to multislice helical 4D CT for radiotherapy with respect to imaging quality, dose, and time has not been thoroughly addressed. As the beginning of such an investigation, this work carries out the initial comparison of reconstructed imaging quality between sparsity regularized iterative method and analytic method through static phantom studies using a state-of-art 128-channel multi-slice Siemens helical CT scanner. Methods: In our iterative method, tensor framelet (TF) is chosen as the regularization method for its superior performance from total variation regularization in terms of reduced piecewise-constant artifacts and improved imaging quality that has been demonstrated in our prior work. On the other hand, X-ray transforms and its adjoints are computed on-the-fly through GPU implementation using our previous developed fast parallel algorithms with O(1) complexity per computing thread. For comparison, both FDK (approximate analytic method) and Katsevich algorithm (exact analytic method) are used for multislice helical CT image reconstruction. Results: The phantom experimental data with different imaging doses were acquired using a state-of-art 128-channel multi-slice Siemens helical CT scanner. The reconstructed image quality was compared between TF-based iterative method, FDK and Katsevich algorithm with the quantitative analysis for characterizing signal-to-noise ratio, image contrast, and spatial resolution of high-contrast and low-contrast objects. Conclusion: The experimental results suggest that our tensor framelet regularized iterative reconstruction algorithm improves the helical CT imaging quality from FDK and Katsevich algorithm for static experimental phantom studies that have been performed

  10. Improving the reconstruction quality with extension and apodization of the digital hologram

    International Nuclear Information System (INIS)

    Zhang Yancao; Zhao Jianlin; Fan Qi; Zhang Wei; Yang Sheng

    2009-01-01

    To suppress the aperture diffraction and spectral leakage effects in the reconstruction process of the digital hologram and to maintain the original information recorded in the hologram, a novel reconstruction method based on extension and apodization of the digital hologram is presented, by which the original hologram can be extended by filling the average intensity values of the boundary, and the extended hologram is apodized by use of the constructed window function. As a sample, the digital hologram of the static particle field is recorded and numerically extended and then apodized with the appointed window. Finally, an unabridged and clear digital holographic image is reconstructed from the extended and apodized hologram. The experimental results confirm that this method cannot only eliminate the black-and-white diffraction fringes in the reconstructed image, but also attain the unabridged image with high quality.

  11. Image quality improvements using adaptive statistical iterative reconstruction for evaluating chronic myocardial infarction using iodine density images with spectral CT.

    Science.gov (United States)

    Kishimoto, Junichi; Ohta, Yasutoshi; Kitao, Shinichiro; Watanabe, Tomomi; Ogawa, Toshihide

    2018-04-01

    Single-source dual-energy CT (ssDECT) allows the reconstruction of iodine density images (IDIs) from projection based computing. We hypothesized that adding adaptive statistical iterative reconstruction (ASiR) could improve image quality. The aim of our study was to evaluate the effect and determine the optimal blend percentages of ASiR for IDI of myocardial late iodine enhancement (LIE) in the evaluation of chronic myocardial infarction using ssDECT. A total of 28 patients underwent cardiac LIE using a ssDECT scanner. IDIs between 0 and 100% of ASiR contributions in 10% increments were reconstructed. The signal-to-noise ratio (SNR) of remote myocardia and the contrast-to-noise ratio (CNR) of infarcted myocardia were measured. Transmural extent of infarction was graded using a 5-point scale. The SNR, CNR, and transmural extent were assessed for each ASiR contribution ratio. The transmural extents were compared with MRI as a reference standard. Compared to 0% ASiR, the use of 20-100% ASiR resulted in a reduction of image noise (p ASiR images, reconstruction with 100% ASiR image showed the highest improvement in SNR (229%; p ASiR above 80% showed the highest ratio (73.7%) of accurate transmural extent classification. In conclusion, ASiR intensity of 80-100% in IDIs can improve image quality without changes in signal and maximizes the accuracy of transmural extent in infarcted myocardium.

  12. Comparison of adaptive statistical iterative reconstruction (ASiRTM) and model-based iterative reconstruction (VeoTM) for paediatric abdominal CT examinations: an observer performance study of diagnostic image quality

    International Nuclear Information System (INIS)

    Hultenmo, Maria; Caisander, Haakan; Mack, Karsten; Thilander-Klang, Anne

    2016-01-01

    The diagnostic image quality of 75 paediatric abdominal computed tomography (CT) examinations reconstructed with two different iterative reconstruction (IR) algorithms-adaptive statistical IR (ASiR TM ) and model-based IR (Veo TM )-was compared. Axial and coronal images were reconstructed with 70 % ASiR with the Soft TM convolution kernel and with the Veo algorithm. The thickness of the reconstructed images was 2.5 or 5 mm depending on the scanning protocol used. Four radiologists graded the delineation of six abdominal structures and the diagnostic usefulness of the image quality. The Veo reconstruction significantly improved the visibility of most of the structures compared with ASiR in all subgroups of images. For coronal images, the Veo reconstruction resulted in significantly improved ratings of the diagnostic use of the image quality compared with the ASiR reconstruction. This was not seen for the axial images. The greatest improvement using Veo reconstruction was observed for the 2.5 mm coronal slices. (authors)

  13. Image quality in children with low-radiation chest CT using adaptive statistical iterative reconstruction and model-based iterative reconstruction.

    Directory of Open Access Journals (Sweden)

    Jihang Sun

    Full Text Available OBJECTIVE: To evaluate noise reduction and image quality improvement in low-radiation dose chest CT images in children using adaptive statistical iterative reconstruction (ASIR and a full model-based iterative reconstruction (MBIR algorithm. METHODS: Forty-five children (age ranging from 28 days to 6 years, median of 1.8 years who received low-dose chest CT scans were included. Age-dependent noise index (NI was used for acquisition. Images were retrospectively reconstructed using three methods: MBIR, 60% of ASIR and 40% of conventional filtered back-projection (FBP, and FBP. The subjective quality of the images was independently evaluated by two radiologists. Objective noises in the left ventricle (LV, muscle, fat, descending aorta and lung field at the layer with the largest cross-section area of LV were measured, with the region of interest about one fourth to half of the area of descending aorta. Optimized signal-to-noise ratio (SNR was calculated. RESULT: In terms of subjective quality, MBIR images were significantly better than ASIR and FBP in image noise and visibility of tiny structures, but blurred edges were observed. In terms of objective noise, MBIR and ASIR reconstruction decreased the image noise by 55.2% and 31.8%, respectively, for LV compared with FBP. Similarly, MBIR and ASIR reconstruction increased the SNR by 124.0% and 46.2%, respectively, compared with FBP. CONCLUSION: Compared with FBP and ASIR, overall image quality and noise reduction were significantly improved by MBIR. MBIR image could reconstruct eligible chest CT images in children with lower radiation dose.

  14. Uncut Esophagojejunostomy with Double Jejunal Pouch: An Alternative Reconstruction Method that Improves the Quality of Life of Patients after Total Gastrectomy.

    Science.gov (United States)

    Gong, Jia Qing; Cao, Yong Kuan; Zhang, Guo Hu; Wang, Pei Hong; Luo, Guo De

    2017-04-01

    Currently, there is no optimal digestive tract reconstruction technique well recognized by scholars after total gastrectomy. In this study, a new reconstruction method, which is modified from the classic Roux-en-Y procedure, an uncut jejunal esophageal anastomosis with double jejunal pouch (UJEA-DJP) was established, and its advantages for improving the quality of life of patients who undergo total gastrectomy were analyzed. Altogether 160 patients with gastric cancer enrolled in our center from September 2009 to March 2012 received radical D2 total gastrectomy. According to the reconstruction methods used, these patients were divided into three groups: UJEA-DJP (n = 63), Roux-en-Y (n = 45), and P-loop with Roux-en-Y esophagojejunostomy (P-RY; n = 52). The operation time for reconstruction, complications, prognostic nutritional index (PNI), and the Visick classification among the three groups were analyzed. We found that UJEA-DJP has advantages over Roux-en-Y and P-RY regarding the time of digestive tract reconstruction, incidence rates for long-term complications, postoperative nutritional index, body weight recovery, and the Visick classification for subjective feelings (p quality of life of patients after surgical procedure.

  15. Iterative model reconstruction: Improved image quality of low-tube-voltage prospective ECG-gated coronary CT angiography images at 256-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Oda, Seitaro, E-mail: seisei0430@nifty.com [Department of Cardiology, MedStar Washington Hospital Center, 110 Irving Street, NW, Washington, DC 20010 (United States); Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556 (Japan); Weissman, Gaby, E-mail: Gaby.Weissman@medstar.net [Department of Cardiology, MedStar Washington Hospital Center, 110 Irving Street, NW, Washington, DC 20010 (United States); Vembar, Mani, E-mail: mani.vembar@philips.com [CT Clinical Science, Philips Healthcare, c595 Miner Road, Cleveland, OH 44143 (United States); Weigold, Wm. Guy, E-mail: Guy.Weigold@MedStar.net [Department of Cardiology, MedStar Washington Hospital Center, 110 Irving Street, NW, Washington, DC 20010 (United States)

    2014-08-15

    Objectives: To investigate the effects of a new model-based type of iterative reconstruction (M-IR) technique, the iterative model reconstruction, on image quality of prospectively gated coronary CT angiography (CTA) acquired at low-tube-voltage. Methods: Thirty patients (16 men, 14 women; mean age 52.2 ± 13.2 years) underwent coronary CTA at 100-kVp on a 256-slice CT. Paired image sets were created using 3 types of reconstruction, i.e. filtered back projection (FBP), a hybrid type of iterative reconstruction (H-IR), and M-IR. Quantitative parameters including CT-attenuation, image noise, and contrast-to-noise ratio (CNR) were measured. The visual image quality, i.e. graininess, beam-hardening, vessel sharpness, and overall image quality, was scored on a 5-point scale. Lastly, coronary artery segments were evaluated using a 4-point scale to investigate the assessability of each segment. Results: There was no significant difference in coronary arterial CT attenuation among the 3 reconstruction methods. The mean image noise of FBP, H-IR, and M-IR images was 29.3 ± 9.6, 19.3 ± 6.9, and 12.9 ± 3.3 HU, respectively, there were significant differences for all comparison combinations among the 3 methods (p < 0.01). The CNR of M-IR was significantly better than of FBP and H-IR images (13.5 ± 5.0 [FBP], 20.9 ± 8.9 [H-IR] and 39.3 ± 13.9 [M-IR]; p < 0.01). The visual scores were significantly higher for M-IR than the other images (p < 0.01), and 95.3% of the coronary segments imaged with M-IR were of assessable quality compared with 76.7% of FBP- and 86.9% of H-IR images. Conclusions: M-IR can provide significantly improved qualitative and quantitative image quality in prospectively gated coronary CTA using a low-tube-voltage.

  16. The Impact of Facial Aesthetic and Reconstructive Surgeries on Patients' Quality of Life.

    Science.gov (United States)

    Yıldız, Tülin; Selimen, Deniz

    2015-12-01

    The aim of the present prospective and descriptive study was to assess the impact of facial aesthetic and reconstructive surgeries on quality of life. Ninety-one patients, of whom 43 had aesthetic surgery and 48 had reconstructive surgery, were analysed. The data were collected using the patient information form, body cathexis scale, and short form (SF)-36 quality of life scale. There were significant differences between before and after the surgery in both groups in terms of body cathexis scale and quality of life (p aesthetic and reconstructive surgery patients before the surgery. However, the problems were decreased, and the quality of life was enhanced after the surgery. Among the parameters of SF-36 quality of life scale, particularly the mean scores of social functioning, physical role functioning, emotional role functioning, mental health, and vitality/fatigue were found low before the surgery, whereas the mean scores were significantly improved after the surgery. The results revealed that facial aesthetic and reconstructive surgical interventions favourably affected the body image perception and self-esteem and that positive reflections in emotional, social, and mental aspects were effective in enhancing self-confidence and quality of life of the individual.

  17. Improved magnetic resonance fingerprinting reconstruction with low-rank and subspace modeling.

    Science.gov (United States)

    Zhao, Bo; Setsompop, Kawin; Adalsteinsson, Elfar; Gagoski, Borjan; Ye, Huihui; Ma, Dan; Jiang, Yun; Ellen Grant, P; Griswold, Mark A; Wald, Lawrence L

    2018-02-01

    This article introduces a constrained imaging method based on low-rank and subspace modeling to improve the accuracy and speed of MR fingerprinting (MRF). A new model-based imaging method is developed for MRF to reconstruct high-quality time-series images and accurate tissue parameter maps (e.g., T 1 , T 2 , and spin density maps). Specifically, the proposed method exploits low-rank approximations of MRF time-series images, and further enforces temporal subspace constraints to capture magnetization dynamics. This allows the time-series image reconstruction problem to be formulated as a simple linear least-squares problem, which enables efficient computation. After image reconstruction, tissue parameter maps are estimated via dictionary-based pattern matching, as in the conventional approach. The effectiveness of the proposed method was evaluated with in vivo experiments. Compared with the conventional MRF reconstruction, the proposed method reconstructs time-series images with significantly reduced aliasing artifacts and noise contamination. Although the conventional approach exhibits some robustness to these corruptions, the improved time-series image reconstruction in turn provides more accurate tissue parameter maps. The improvement is pronounced especially when the acquisition time becomes short. The proposed method significantly improves the accuracy of MRF, and also reduces data acquisition time. Magn Reson Med 79:933-942, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  18. Imaging reconstruction based on improved wavelet denoising combined with parallel-beam filtered back-projection algorithm

    Science.gov (United States)

    Ren, Zhong; Liu, Guodong; Huang, Zhen

    2012-11-01

    The image reconstruction is a key step in medical imaging (MI) and its algorithm's performance determinates the quality and resolution of reconstructed image. Although some algorithms have been used, filter back-projection (FBP) algorithm is still the classical and commonly-used algorithm in clinical MI. In FBP algorithm, filtering of original projection data is a key step in order to overcome artifact of the reconstructed image. Since simple using of classical filters, such as Shepp-Logan (SL), Ram-Lak (RL) filter have some drawbacks and limitations in practice, especially for the projection data polluted by non-stationary random noises. So, an improved wavelet denoising combined with parallel-beam FBP algorithm is used to enhance the quality of reconstructed image in this paper. In the experiments, the reconstructed effects were compared between the improved wavelet denoising and others (directly FBP, mean filter combined FBP and median filter combined FBP method). To determine the optimum reconstruction effect, different algorithms, and different wavelet bases combined with three filters were respectively test. Experimental results show the reconstruction effect of improved FBP algorithm is better than that of others. Comparing the results of different algorithms based on two evaluation standards i.e. mean-square error (MSE), peak-to-peak signal-noise ratio (PSNR), it was found that the reconstructed effects of the improved FBP based on db2 and Hanning filter at decomposition scale 2 was best, its MSE value was less and the PSNR value was higher than others. Therefore, this improved FBP algorithm has potential value in the medical imaging.

  19. Accuracy improvement of CT reconstruction using tree-structured filter bank

    International Nuclear Information System (INIS)

    Ueda, Kazuhiro; Morimoto, Hiroaki; Morikawa, Yoshitaka; Murakami, Junichi

    2009-01-01

    Accuracy improvement of 'CT reconstruction algorithm using TSFB (Tree-Structured Filter Bank)' that is high-speed CT reconstruction algorithm, was proposed. TSFB method could largely reduce the amount of computation in comparison with the CB (Convolution Backprojection) method, but it was the problem that an artifact occurred in a reconstruction image since reconstruction was performed with disregard to a signal out of the reconstruction domain in stage processing. Also the whole band filter being the component of a two-dimensional synthesis filter was IIR filter and then an artifact occurred at the end of the reconstruction image. In order to suppress these artifacts the proposed method enlarged the processing range by the TSFB method in the domain outside by the width control of the specimen line and line addition to the reconstruction domain outside. And, furthermore, to avoid increase of the amount of computation, the algorithm was proposed such as to decide the needed processing range depending on the number of steps processing with the TSFB and the degree of incline of filter, and then update the position and width of the specimen line to process the needed range. According to the simulation to realize a high-speed and highly accurate CT reconstruction in this way, the quality of the reconstruction image of the proposed method was improved in comparison with the TSFB method and got the same result with the CB method. (T. Tanaka)

  20. Do psychosocial interventions improve rehabilitation outcomes after anterior cruciate ligament reconstruction? A systematic review.

    Science.gov (United States)

    Coronado, Rogelio A; Bird, Mackenzie L; Van Hoy, Erin E; Huston, Laura J; Spindler, Kurt P; Archer, Kristin R

    2018-03-01

    To examine the role of psychosocial interventions in improving patient-reported clinical outcomes, including return to sport/activity, and intermediary psychosocial factors after anterior cruciate ligament reconstruction. MEDLINE/PubMed, CINAHL, PsycINFO, and Web of Science were searched from each database's inception to March 2017 for published studies in patients after anterior cruciate ligament reconstruction. Studies were included if they reported on the effects of a postoperative psychosocial intervention on a patient-reported clinical measure of disability, function, pain, quality of life, return to sport/activity, or intermediary psychosocial factor. Data were extracted using a standardized form and summary effects from each article were compiled. The methodological quality of randomized trials was assessed using the Physiotherapy Evidence Database Scale and scores greater than 5/10 were considered high quality. A total of 893 articles were identified from the literature search. Of these, four randomized trials ( N = 210) met inclusion criteria. The four articles examined guided imagery and relaxation, coping modeling, and visual imagery as postoperative psychosocial interventions. Methodological quality scores of the studies ranged from 5 to 9. There were inconsistent findings for the additive benefit of psychosocial interventions for improving postoperative function, pain, or self-efficacy and limited evidence for improving postoperative quality of life, anxiety, or fear of reinjury. No study examined the effects of psychosocial interventions on return to sport/activity. Overall, there is limited evidence on the efficacy of postoperative psychosocial interventions for improving functional recovery after anterior cruciate ligament reconstruction.

  1. CT coronary angiography: Influence of different cardiac reconstruction intervals on image quality and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Department of Radiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: marc.dewey@charite.de; Teige, Florian [Department of Radiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany); Rutsch, Wolfgang [Department of Cardiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: wolfgang.rutsch@charite.de; Schink, Tania [Department of Medical Biometry, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: peter.martus@charite.de; Hamm, Bernd [Department of Radiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)

    2008-07-15

    Purpose: To prospectively analyze image quality and diagnostic accuracy of different reconstruction intervals of coronary angiography using multislice computed tomography (MSCT). Materials and methods: For each of 47 patients, 10 ECG-gated MSCT reconstructions were generated throughout the RR interval from 0 to 90%, resulting in altogether 470 datasets. These datasets were randomly analyzed for image quality and accuracy and compared with conventional angiography. Statistical comparison of intervals was performed using nonparametric analysis for repeated measurements to account for clustering of arteries within patients. Results: Image reconstruction intervals centered at 80, 70, and 40% of the RR interval resulted (in that order) in the best overall image quality for all four main coronary vessels. Eighty percent reconstructions also yielded the highest diagnostic accuracy of all intervals. The combination of the three best intervals (80, 70, and 40%) significantly reduced the nondiagnostic rate as compared with 80% alone (p = 0.005). However, the optimal reconstruction interval combination achieved significantly improved specificities and nondiagnostic rates (p < 0.05). The optimal combination consisted of 1.7 {+-} 0.9 reconstruction intervals on average. In approximately half of the patients (49%, 23/47) a single reconstruction was optimal. In 18 (38%), 3 (6%), and 3 (6%) patients one, two, and three additional reconstruction intervals were required, respectively, to achieve optimal quality. In 28% of the patients the optimal combination consisted of reconstructions other than the three best intervals (80, 70, and 40%). Conclusion: Multiple image reconstruction intervals are essential to ensure high image quality and accuracy of CT coronary angiography.

  2. New reconstruction algorithm for digital breast tomosynthesis: better image quality for humans and computers.

    Science.gov (United States)

    Rodriguez-Ruiz, Alejandro; Teuwen, Jonas; Vreemann, Suzan; Bouwman, Ramona W; van Engen, Ruben E; Karssemeijer, Nico; Mann, Ritse M; Gubern-Merida, Albert; Sechopoulos, Ioannis

    2017-01-01

    Background The image quality of digital breast tomosynthesis (DBT) volumes depends greatly on the reconstruction algorithm. Purpose To compare two DBT reconstruction algorithms used by the Siemens Mammomat Inspiration system, filtered back projection (FBP), and FBP with iterative optimizations (EMPIRE), using qualitative analysis by human readers and detection performance of machine learning algorithms. Material and Methods Visual grading analysis was performed by four readers specialized in breast imaging who scored 100 cases reconstructed with both algorithms (70 lesions). Scoring (5-point scale: 1 = poor to 5 = excellent quality) was performed on presence of noise and artifacts, visualization of skin-line and Cooper's ligaments, contrast, and image quality, and, when present, lesion visibility. In parallel, a three-dimensional deep-learning convolutional neural network (3D-CNN) was trained (n = 259 patients, 51 positives with BI-RADS 3, 4, or 5 calcifications) and tested (n = 46 patients, nine positives), separately with FBP and EMPIRE volumes, to discriminate between samples with and without calcifications. The partial area under the receiver operating characteristic curve (pAUC) of each 3D-CNN was used for comparison. Results EMPIRE reconstructions showed better contrast (3.23 vs. 3.10, P = 0.010), image quality (3.22 vs. 3.03, P algorithm provides DBT volumes with better contrast and image quality, fewer artifacts, and improved visibility of calcifications for human observers, as well as improved detection performance with deep-learning algorithms.

  3. SU-E-I-82: Improving CT Image Quality for Radiation Therapy Using Iterative Reconstruction Algorithms and Slightly Increasing Imaging Doses

    International Nuclear Information System (INIS)

    Noid, G; Chen, G; Tai, A; Li, X

    2014-01-01

    Purpose: Iterative reconstruction (IR) algorithms are developed to improve CT image quality (IQ) by reducing noise without diminishing spatial resolution or contrast. For CT in radiation therapy (RT), slightly increasing imaging dose to improve IQ may be justified if it can substantially enhance structure delineation. The purpose of this study is to investigate and to quantify the IQ enhancement as a result of increasing imaging doses and using IR algorithms. Methods: CT images were acquired for phantoms, built to evaluate IQ metrics including spatial resolution, contrast and noise, with a variety of imaging protocols using a CT scanner (Definition AS Open, Siemens) installed inside a Linac room. Representative patients were scanned once the protocols were optimized. Both phantom and patient scans were reconstructed using the Sinogram Affirmed Iterative Reconstruction (SAFIRE) and the Filtered Back Projection (FBP) methods. IQ metrics of the obtained CTs were compared. Results: IR techniques are demonstrated to preserve spatial resolution as measured by the point spread function and reduce noise in comparison to traditional FBP. Driven by the reduction in noise, the contrast to noise ratio is doubled by adopting the highest SAFIRE strength. As expected, increasing imaging dose reduces noise for both SAFIRE and FBP reconstructions. The contrast to noise increases from 3 to 5 by increasing the dose by a factor of 4. Similar IQ improvement was observed on the CTs for selected patients with pancreas and prostrate cancers. Conclusion: The IR techniques produce a measurable enhancement to CT IQ by reducing the noise. Increasing imaging dose further reduces noise independent of the IR techniques. The improved CT enables more accurate delineation of tumors and/or organs at risk during RT planning and delivery guidance

  4. Intraoperative Nerve Blocks Fail to Improve Quality of Recovery after Tissue Expander Breast Reconstruction: A Prospective, Double-Blinded, Randomized, Placebo-Controlled Clinical Trial.

    Science.gov (United States)

    Lanier, Steven T; Lewis, Kevin C; Kendall, Mark C; Vieira, Brittany L; De Oliveira, Gildasio; Nader, Anthony; Kim, John Y S; Alghoul, Mohammed

    2018-03-01

    The authors' study represents the first level I evidence to assess whether intraoperative nerve blocks improve the quality of recovery from immediate tissue expander/implant breast reconstruction. A prospective, randomized, double-blinded, placebo-controlled clinical trial was conducted in which patients undergoing immediate tissue expander/implant breast reconstruction were randomized to either (1) intraoperative intercostal and pectoral nerve blocks with 0.25% bupivacaine with 1:200,000 epinephrine and 4 mg of dexamethasone or (2) sham nerve blocks with normal saline. The 40-item Quality of Recovery score, pain score, and opioid use in the postoperative period were compared statistically between groups. Power analysis ensured 80 percent power to detect a 10-point (clinically significant) difference in the 40-item Quality of Recovery score. Forty-seven patients were enrolled. Age, body mass index, laterality, mastectomy type, and lymph node dissection were similar between groups. There were no statistical differences in quality of recovery, pain burden as measured by visual analogue scale, opioid consumption, antiemetic use, or length of hospital stay between groups at 24 hours after surgery. Mean global 40-item Quality of Recovery scores were 169 (range, 155 to 182) for the treatment arm and 165 (range, 143 to 179) for the placebo arm (p = 0.36), indicating a high quality of recovery in both groups. Although intraoperative nerve blocks can be a safe adjunct to a comprehensive postsurgical recovery regimen, the authors' results indicate no effect on overall quality of recovery from tissue expander/implant breast reconstruction. Therapeutic, I.

  5. Bayesian image reconstruction for improving detection performance of muon tomography.

    Science.gov (United States)

    Wang, Guobao; Schultz, Larry J; Qi, Jinyi

    2009-05-01

    Muon tomography is a novel technology that is being developed for detecting high-Z materials in vehicles or cargo containers. Maximum likelihood methods have been developed for reconstructing the scattering density image from muon measurements. However, the instability of maximum likelihood estimation often results in noisy images and low detectability of high-Z targets. In this paper, we propose using regularization to improve the image quality of muon tomography. We formulate the muon reconstruction problem in a Bayesian framework by introducing a prior distribution on scattering density images. An iterative shrinkage algorithm is derived to maximize the log posterior distribution. At each iteration, the algorithm obtains the maximum a posteriori update by shrinking an unregularized maximum likelihood update. Inverse quadratic shrinkage functions are derived for generalized Laplacian priors and inverse cubic shrinkage functions are derived for generalized Gaussian priors. Receiver operating characteristic studies using simulated data demonstrate that the Bayesian reconstruction can greatly improve the detection performance of muon tomography.

  6. Influence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography.

    Science.gov (United States)

    Precht, Helle; Thygesen, Jesper; Gerke, Oke; Egstrup, Kenneth; Waaler, Dag; Lambrechtsen, Jess

    2016-12-01

    Coronary computed tomography angiography (CCTA) requires high spatial and temporal resolution, increased low contrast resolution for the assessment of coronary artery stenosis, plaque detection, and/or non-coronary pathology. Therefore, new reconstruction algorithms, particularly iterative reconstruction (IR) techniques, have been developed in an attempt to improve image quality with no cost in radiation exposure. To evaluate whether adaptive statistical iterative reconstruction (ASIR) enhances perceived image quality in CCTA compared to filtered back projection (FBP). Thirty patients underwent CCTA due to suspected coronary artery disease. Images were reconstructed using FBP, 30% ASIR, and 60% ASIR. Ninety image sets were evaluated by five observers using the subjective visual grading analysis (VGA) and assessed by proportional odds modeling. Objective quality assessment (contrast, noise, and the contrast-to-noise ratio [CNR]) was analyzed with linear mixed effects modeling on log-transformed data. The need for ethical approval was waived by the local ethics committee as the study only involved anonymously collected clinical data. VGA showed significant improvements in sharpness by comparing FBP with ASIR, resulting in odds ratios of 1.54 for 30% ASIR and 1.89 for 60% ASIR ( P  = 0.004). The objective measures showed significant differences between FBP and 60% ASIR ( P  < 0.0001) for noise, with an estimated ratio of 0.82, and for CNR, with an estimated ratio of 1.26. ASIR improved the subjective image quality of parameter sharpness and, objectively, reduced noise and increased CNR.

  7. Optimization of the alpha image reconstruction. An iterative CT-image reconstruction with well-defined image quality metrics

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, Sergej; Sawall, Stefan; Knaup, Michael; Kachelriess, Marc [German Cancer Research Center, Heidelberg (Germany).

    2017-10-01

    Optimization of the AIR-algorithm for improved convergence and performance. TThe AIR method is an iterative algorithm for CT image reconstruction. As a result of its linearity with respect to the basis images, the AIR algorithm possesses well defined, regular image quality metrics, e.g. point spread function (PSF) or modulation transfer function (MTF), unlike other iterative reconstruction algorithms. The AIR algorithm computes weighting images α to blend between a set of basis images that preferably have mutually exclusive properties, e.g. high spatial resolution or low noise. The optimized algorithm uses an approach that alternates between the optimization of rawdata fidelity using an OSSART like update and regularization using gradient descent, as opposed to the initially proposed AIR using a straightforward gradient descent implementation. A regularization strength for a given task is chosen by formulating a requirement for the noise reduction and checking whether it is fulfilled for different regularization strengths, while monitoring the spatial resolution using the voxel-wise defined modulation transfer function for the AIR image. The optimized algorithm computes similar images in a shorter time compared to the initial gradient descent implementation of AIR. The result can be influenced by multiple parameters that can be narrowed down to a relatively simple framework to compute high quality images. The AIR images, for instance, can have at least a 50% lower noise level compared to the sharpest basis image, while the spatial resolution is mostly maintained. The optimization improves performance by a factor of 6, while maintaining image quality. Furthermore, it was demonstrated that the spatial resolution for AIR can be determined using regular image quality metrics, given smooth weighting images. This is not possible for other iterative reconstructions as a result of their non linearity. A simple set of parameters for the algorithm is discussed that provides

  8. Optimization of the alpha image reconstruction. An iterative CT-image reconstruction with well-defined image quality metrics

    International Nuclear Information System (INIS)

    Lebedev, Sergej; Sawall, Stefan; Knaup, Michael; Kachelriess, Marc

    2017-01-01

    Optimization of the AIR-algorithm for improved convergence and performance. TThe AIR method is an iterative algorithm for CT image reconstruction. As a result of its linearity with respect to the basis images, the AIR algorithm possesses well defined, regular image quality metrics, e.g. point spread function (PSF) or modulation transfer function (MTF), unlike other iterative reconstruction algorithms. The AIR algorithm computes weighting images α to blend between a set of basis images that preferably have mutually exclusive properties, e.g. high spatial resolution or low noise. The optimized algorithm uses an approach that alternates between the optimization of rawdata fidelity using an OSSART like update and regularization using gradient descent, as opposed to the initially proposed AIR using a straightforward gradient descent implementation. A regularization strength for a given task is chosen by formulating a requirement for the noise reduction and checking whether it is fulfilled for different regularization strengths, while monitoring the spatial resolution using the voxel-wise defined modulation transfer function for the AIR image. The optimized algorithm computes similar images in a shorter time compared to the initial gradient descent implementation of AIR. The result can be influenced by multiple parameters that can be narrowed down to a relatively simple framework to compute high quality images. The AIR images, for instance, can have at least a 50% lower noise level compared to the sharpest basis image, while the spatial resolution is mostly maintained. The optimization improves performance by a factor of 6, while maintaining image quality. Furthermore, it was demonstrated that the spatial resolution for AIR can be determined using regular image quality metrics, given smooth weighting images. This is not possible for other iterative reconstructions as a result of their non linearity. A simple set of parameters for the algorithm is discussed that provides

  9. Distance weighting for improved tomographic reconstructions

    International Nuclear Information System (INIS)

    Koeppe, R.A.; Holden, J.E.

    1984-01-01

    An improved method for the reconstruction of emission computed axial tomography images has been developed. The method is a modification of filtered back-projection, where the back projected values are weighted to reflect the loss of formation, with distance from the camera, which is inherent in gamma camera imaging. This information loss is a result of: loss of spatial resolution with distance, attenuation, and scatter. The weighting scheme can best be described by considering the contributions of any two opposing views to the reconstruction image pixels. The weight applied to the projections of one view is set to equal the relative amount of the original activity that was initially received in that projection, assuming a uniform attenuating medium. This yields a weighting value which is a function of distance into the image with a value of one for pixels ''near the camera'', a value of .5 at the image center, and a value of zero on the opposite side. Tomographic reconstructions produced with this method show improved spatial resolution when compared to conventional 360 0 reconstructions. The improvement is in the tangential direction, where simulations have indicated a FWHM improvement of 1 to 1.5 millimeters. The resolution in the radial direction is essentially the same for both methods. Visual inspection of the reconstructed images show improved resolution and contrast

  10. Assessment of noise reduction potential and image quality improvement of a new generation adaptive statistical iterative reconstruction (ASIR-V) in chest CT.

    Science.gov (United States)

    Tang, Hui; Yu, Nan; Jia, Yongjun; Yu, Yong; Duan, Haifeng; Han, Dong; Ma, Guangming; Ren, Chenglong; He, Taiping

    2018-01-01

    To evaluate the image quality improvement and noise reduction in routine dose, non-enhanced chest CT imaging by using a new generation adaptive statistical iterative reconstruction (ASIR-V) in comparison with ASIR algorithm. 30 patients who underwent routine dose, non-enhanced chest CT using GE Discovery CT750HU (GE Healthcare, Waukesha, WI) were included. The scan parameters included tube voltage of 120 kVp, automatic tube current modulation to obtain a noise index of 14HU, rotation speed of 0.6 s, pitch of 1.375:1 and slice thickness of 5 mm. After scanning, all scans were reconstructed with the recommended level of 40%ASIR for comparison purpose and different percentages of ASIR-V from 10% to 100% in a 10% increment. The CT attenuation values and SD of the subcutaneous fat, back muscle and descending aorta were measured at the level of tracheal carina of all reconstructed images. The signal-to-noise ratio (SNR) was calculated with SD representing image noise. The subjective image quality was independently evaluated by two experienced radiologists. For all ASIR-V images, the objective image noise (SD) of fat, muscle and aorta decreased and SNR increased along with increasing ASIR-V percentage. The SD of 30% ASIR-V to 100% ASIR-V was significantly lower than that of 40% ASIR (p ASIR-V reconstructions had good diagnostic acceptability. However, the 50% ASIR-V to 70% ASIR-V series showed significantly superior visibility of small structures when compared with the 40% ASIR and ASIR-V of other percentages (p ASIR-V was the best series of all ASIR-V images, with a highest subjective image quality. The image sharpness was significantly decreased in images reconstructed by 80% ASIR-V and higher. In routine dose, non-enhanced chest CT, ASIR-V shows greater potential in reducing image noise and artefacts and maintaining image sharpness when compared to the recommended level of 40%ASIR algorithm. Combining both the objective and subjective evaluation of images, non

  11. Influence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Helle Precht

    2016-12-01

    Full Text Available Background Coronary computed tomography angiography (CCTA requires high spatial and temporal resolution, increased low contrast resolution for the assessment of coronary artery stenosis, plaque detection, and/or non-coronary pathology. Therefore, new reconstruction algorithms, particularly iterative reconstruction (IR techniques, have been developed in an attempt to improve image quality with no cost in radiation exposure. Purpose To evaluate whether adaptive statistical iterative reconstruction (ASIR enhances perceived image quality in CCTA compared to filtered back projection (FBP. Material and Methods Thirty patients underwent CCTA due to suspected coronary artery disease. Images were reconstructed using FBP, 30% ASIR, and 60% ASIR. Ninety image sets were evaluated by five observers using the subjective visual grading analysis (VGA and assessed by proportional odds modeling. Objective quality assessment (contrast, noise, and the contrast-to-noise ratio [CNR] was analyzed with linear mixed effects modeling on log-transformed data. The need for ethical approval was waived by the local ethics committee as the study only involved anonymously collected clinical data. Results VGA showed significant improvements in sharpness by comparing FBP with ASIR, resulting in odds ratios of 1.54 for 30% ASIR and 1.89 for 60% ASIR (P = 0.004. The objective measures showed significant differences between FBP and 60% ASIR (P < 0.0001 for noise, with an estimated ratio of 0.82, and for CNR, with an estimated ratio of 1.26. Conclusion ASIR improved the subjective image quality of parameter sharpness and, objectively, reduced noise and increased CNR.

  12. Novel edge treatment method for improving the transmission reconstruction quality in Tomographic Gamma Scanning.

    Science.gov (United States)

    Han, Miaomiao; Guo, Zhirong; Liu, Haifeng; Li, Qinghua

    2018-05-01

    Tomographic Gamma Scanning (TGS) is a method used for the nondestructive assay of radioactive wastes. In TGS, the actual irregular edge voxels are regarded as regular cubic voxels in the traditional treatment method. In this study, in order to improve the performance of TGS, a novel edge treatment method is proposed that considers the actual shapes of these voxels. The two different edge voxel treatment methods were compared by computing the pixel-level relative errors and normalized mean square errors (NMSEs) between the reconstructed transmission images and the ideal images. Both methods were coupled with two different interative algorithms comprising Algebraic Reconstruction Technique (ART) with a non-negativity constraint and Maximum Likelihood Expectation Maximization (MLEM). The results demonstrated that the traditional method for edge voxel treatment can introduce significant error and that the real irregular edge voxel treatment method can improve the performance of TGS by obtaining better transmission reconstruction images. With the real irregular edge voxel treatment method, MLEM algorithm and ART algorithm can be comparable when assaying homogenous matrices, but MLEM algorithm is superior to ART algorithm when assaying heterogeneous matrices. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Improvements for real-time magnetic equilibrium reconstruction on ASDEX Upgrade

    International Nuclear Information System (INIS)

    Giannone, L.; Fischer, R.; McCarthy, P.J.; Odstrcil, T.; Zammuto, I.; Bock, A.; Conway, G.; Fuchs, J.C.; Gude, A.; Igochine, V.; Kallenbach, A.; Lackner, K.; Maraschek, M.; Rapson, C.; Ruan, Q.; Schuhbeck, K.H.; Suttrop, W.; Wenzel, L.

    2015-01-01

    Highlights: • Spline basis current functions with second-order linear regularisation. • Perturbations of magnetic probe measurements due to ferromagnetic tiles on the inner wall and from oscillations in the fast position coil current are corrected. • A constraint of the safety factor on the magnetic axis is introduced. Soft X-ray tomography is used to assess the quality of the real-time magnetic equilibrium reconstruction. • External loop voltage measurements and magnetic probe pairs inside and outside the vessel wall were used to measure the vacuum vessel wall resistivity. - Abstract: Real-time magnetic equilibria are needed for NTM stabilization and disruption avoidance experiments on ASDEX Upgrade. Five improvements to real-time magnetic equilibrium reconstruction on ASDEX Upgrade have been investigated. The aim is to include as many features of the offline magnetic equilibrium reconstruction code in the real-time equilibrium reconstruction code. Firstly, spline current density basis functions with regularization are used in the offline equilibrium reconstruction code, CLISTE [1]. It is now possible to have the same number of spline basis functions in the real-time code. Secondly, in the presence of edge localized modes, (ELM's), it is found to be necessary to include the low pass filter effect of the vacuum vessel on the fast position control coil currents to correctly compensate the magnetic probes for current oscillations in these coils. Thirdly, the introduction of ferromagnetic tiles in ASDEX Upgrade means that a real-time algorithm for including the perturbations of the magnetic equilibrium generated by these tiles is required. A methodology based on tile surface currents is described. Fourthly, during current ramps it was seen that the difference between fitted and measured magnetic measurements in the equilibrium reconstruction were larger than in the constant current phase. External loop voltage measurements and magnetic probe pairs inside and

  14. Improvements for real-time magnetic equilibrium reconstruction on ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Giannone, L.; Fischer, R. [Max Planck Institute for Plasma Physics, 85748 Garching (Germany); McCarthy, P.J. [Department of Physics, University College Cork, Cork (Ireland); Odstrcil, T.; Zammuto, I.; Bock, A.; Conway, G.; Fuchs, J.C.; Gude, A.; Igochine, V.; Kallenbach, A.; Lackner, K.; Maraschek, M.; Rapson, C. [Max Planck Institute for Plasma Physics, 85748 Garching (Germany); Ruan, Q. [National Instruments, Austin, TX 78759-3504 (United States); Schuhbeck, K.H.; Suttrop, W. [Max Planck Institute for Plasma Physics, 85748 Garching (Germany); Wenzel, L. [National Instruments, Austin, TX 78759-3504 (United States)

    2015-11-15

    Highlights: • Spline basis current functions with second-order linear regularisation. • Perturbations of magnetic probe measurements due to ferromagnetic tiles on the inner wall and from oscillations in the fast position coil current are corrected. • A constraint of the safety factor on the magnetic axis is introduced. Soft X-ray tomography is used to assess the quality of the real-time magnetic equilibrium reconstruction. • External loop voltage measurements and magnetic probe pairs inside and outside the vessel wall were used to measure the vacuum vessel wall resistivity. - Abstract: Real-time magnetic equilibria are needed for NTM stabilization and disruption avoidance experiments on ASDEX Upgrade. Five improvements to real-time magnetic equilibrium reconstruction on ASDEX Upgrade have been investigated. The aim is to include as many features of the offline magnetic equilibrium reconstruction code in the real-time equilibrium reconstruction code. Firstly, spline current density basis functions with regularization are used in the offline equilibrium reconstruction code, CLISTE [1]. It is now possible to have the same number of spline basis functions in the real-time code. Secondly, in the presence of edge localized modes, (ELM's), it is found to be necessary to include the low pass filter effect of the vacuum vessel on the fast position control coil currents to correctly compensate the magnetic probes for current oscillations in these coils. Thirdly, the introduction of ferromagnetic tiles in ASDEX Upgrade means that a real-time algorithm for including the perturbations of the magnetic equilibrium generated by these tiles is required. A methodology based on tile surface currents is described. Fourthly, during current ramps it was seen that the difference between fitted and measured magnetic measurements in the equilibrium reconstruction were larger than in the constant current phase. External loop voltage measurements and magnetic probe pairs inside

  15. Investigation of various reconstruction parameters for algebraic reconstruction technique in a newly developed chest digital tomosynthesis

    International Nuclear Information System (INIS)

    Lee, H.; Choi, S.; Kim, Y.-S.; Park, H.-S.; Seo, C.-W.; Kim, H.-J.; Lee, D.; Lee, Y.

    2017-01-01

    Chest digital tomosynthesis (CDT) is a promising new modality that provides 3D information by reconstructing limited projection views. CDT systems have been developed to improve the limitations of conventional radiography such as image degradation and low sensitivity. However, the development of reconstruction methods is challenging because of the limited projection views within various angular ranges. Optimization of reconstruction parameters for various reconsturction methods in CDT system also is needed. The purpose of this study was to investigate the feasibility of algebraic reconstruction technique (ART) method, and to evaluate the effect of the reconstruction parameters for our newly developed CDT system. We designed ART method with 41 projection views over an angular range of ±20°. To investigate the effect of reconstruction parameters, we measured the contrast-to-noise ratio (CNR), artifact spread function (ASF), and quality factor (QF) using LUNGMAN phantom included tumors. We found that the proper choice of reconstruction parameters such as relaxation parameter, initial guess, and number of iterations improved the quality of reconstructed images from the same projection views. Optimal values of ART relaxation parameter with uniform (UI) and back-projection (BP) initial guesses were 0.4 and 0.6, respectively. BP initial guess improved image quality in comparison with UI initial guess, in terms of providing a higher CNR and QF values with a faster speed. CNR and QF values improved with increasing number of iteration. Particularly, ART method with BP initial guess (when β = 0.6) after 3-terations provide satisfactory reconstructed image. In conclusion, the use of ART method with proper reconstruction parameters provided better image quality than FBP method as well as conventional radiography. These results indicated that the ART method with optimal reconstruction parameters could improve image quality for nodule detection using the CDT system.

  16. Investigation of various reconstruction parameters for algebraic reconstruction technique in a newly developed chest digital tomosynthesis

    Science.gov (United States)

    Lee, H.; Choi, S.; Lee, D.; Kim, Y.-s.; Park, H.-S.; Lee, Y.; Seo, C.-W.; Kim, H.-J.

    2017-08-01

    Chest digital tomosynthesis (CDT) is a promising new modality that provides 3D information by reconstructing limited projection views. CDT systems have been developed to improve the limitations of conventional radiography such as image degradation and low sensitivity. However, the development of reconstruction methods is challenging because of the limited projection views within various angular ranges. Optimization of reconstruction parameters for various reconsturction methods in CDT system also is needed. The purpose of this study was to investigate the feasibility of algebraic reconstruction technique (ART) method, and to evaluate the effect of the reconstruction parameters for our newly developed CDT system. We designed ART method with 41 projection views over an angular range of ±20°. To investigate the effect of reconstruction parameters, we measured the contrast-to-noise ratio (CNR), artifact spread function (ASF), and quality factor (QF) using LUNGMAN phantom included tumors. We found that the proper choice of reconstruction parameters such as relaxation parameter, initial guess, and number of iterations improved the quality of reconstructed images from the same projection views. Optimal values of ART relaxation parameter with uniform (UI) and back-projection (BP) initial guesses were 0.4 and 0.6, respectively. BP initial guess improved image quality in comparison with UI initial guess, in terms of providing a higher CNR and QF values with a faster speed. CNR and QF values improved with increasing number of iteration. Particularly, ART method with BP initial guess (when β = 0.6) after 3-terations provide satisfactory reconstructed image. In conclusion, the use of ART method with proper reconstruction parameters provided better image quality than FBP method as well as conventional radiography. These results indicated that the ART method with optimal reconstruction parameters could improve image quality for nodule detection using the CDT system.

  17. Initial phantom study comparing image quality in computed tomography using adaptive statistical iterative reconstruction and new adaptive statistical iterative reconstruction v.

    Science.gov (United States)

    Lim, Kyungjae; Kwon, Heejin; Cho, Jinhan; Oh, Jongyoung; Yoon, Seongkuk; Kang, Myungjin; Ha, Dongho; Lee, Jinhwa; Kang, Eunju

    2015-01-01

    The purpose of this study was to assess the image quality of a novel advanced iterative reconstruction (IR) method called as "adaptive statistical IR V" (ASIR-V) by comparing the image noise, contrast-to-noise ratio (CNR), and spatial resolution from those of filtered back projection (FBP) and adaptive statistical IR (ASIR) on computed tomography (CT) phantom image. We performed CT scans at 5 different tube currents (50, 70, 100, 150, and 200 mA) using 3 types of CT phantoms. Scanned images were subsequently reconstructed in 7 different scan settings, such as FBP, and 3 levels of ASIR and ASIR-V (30%, 50%, and 70%). The image noise was measured in the first study using body phantom. The CNR was measured in the second study using contrast phantom and the spatial resolutions were measured in the third study using a high-resolution phantom. We compared the image noise, CNR, and spatial resolution among the 7 reconstructed image scan settings to determine whether noise reduction, high CNR, and high spatial resolution could be achieved at ASIR-V. At quantitative analysis of the first and second studies, it showed that the images reconstructed using ASIR-V had reduced image noise and improved CNR compared with those of FBP and ASIR (P ASIR-V had significantly improved spatial resolution than those of FBP and ASIR (P ASIR-V provides a significant reduction in image noise and a significant improvement in CNR as well as spatial resolution. Therefore, this technique has the potential to reduce the radiation dose further without compromising image quality.

  18. Software metrics to improve software quality in HEP

    International Nuclear Information System (INIS)

    Lancon, E.

    1996-01-01

    The ALEPH reconstruction program maintainability has been evaluated with a case tool implementing an ISO standard methodology based on software metrics. It has been found that the overall quality of the program is good and has shown improvement over the past five years. Frequently modified routines exhibits lower quality; most buys were located in routines with particularly low quality. Implementing from the beginning a quality criteria could have avoided time losses due to bug corrections. (author)

  19. Improving automated 3D reconstruction methods via vision metrology

    Science.gov (United States)

    Toschi, Isabella; Nocerino, Erica; Hess, Mona; Menna, Fabio; Sargeant, Ben; MacDonald, Lindsay; Remondino, Fabio; Robson, Stuart

    2015-05-01

    This paper aims to provide a procedure for improving automated 3D reconstruction methods via vision metrology. The 3D reconstruction problem is generally addressed using two different approaches. On the one hand, vision metrology (VM) systems try to accurately derive 3D coordinates of few sparse object points for industrial measurement and inspection applications; on the other, recent dense image matching (DIM) algorithms are designed to produce dense point clouds for surface representations and analyses. This paper strives to demonstrate a step towards narrowing the gap between traditional VM and DIM approaches. Efforts are therefore intended to (i) test the metric performance of the automated photogrammetric 3D reconstruction procedure, (ii) enhance the accuracy of the final results and (iii) obtain statistical indicators of the quality achieved in the orientation step. VM tools are exploited to integrate their main functionalities (centroid measurement, photogrammetric network adjustment, precision assessment, etc.) into the pipeline of 3D dense reconstruction. Finally, geometric analyses and accuracy evaluations are performed on the raw output of the matching (i.e. the point clouds) by adopting a metrological approach. The latter is based on the use of known geometric shapes and quality parameters derived from VDI/VDE guidelines. Tests are carried out by imaging the calibrated Portable Metric Test Object, designed and built at University College London (UCL), UK. It allows assessment of the performance of the image orientation and matching procedures within a typical industrial scenario, characterised by poor texture and known 3D/2D shapes.

  20. A fully three-dimensional reconstruction algorithm with the nonstationary filter for improved single-orbit cone beam SPECT

    International Nuclear Information System (INIS)

    Cao, Z.J.; Tsui, B.M.

    1993-01-01

    Conventional single-orbit cone beam tomography presents special problems. They include incomplete sampling and inadequate three-dimensional (3D) reconstruction algorithm. The commonly used Feldkamp reconstruction algorithm simply extends the two-dimensional (2D) fan beam algorithm to 3D cone beam geometry. A truly 3D reconstruction formulation has been derived for the single-orbit cone beam SPECT based on the 3D Fourier slice theorem. In the formulation, a nonstationary filter which depends on the distance from the central plane of the cone beam was derived. The filter is applied to the 2D projection data in directions along and normal to the axis-of-rotation. The 3D reconstruction algorithm with the nonstationary filter was evaluated using both computer simulation and experimental measurements. Significant improvement in image quality was demonstrated in terms of decreased artifacts and distortions in cone beam reconstructed images. However, compared with the Feldkamp algorithm, a five-fold increase in processing time is required. Further improvement in image quality needs complete sampling in frequency space

  1. An improved cone-beam filtered backprojection reconstruction algorithm based on x-ray angular correction and multiresolution analysis

    International Nuclear Information System (INIS)

    Sun, Y.; Hou, Y.; Yan, Y.

    2004-01-01

    With the extensive application of industrial computed tomography in the field of non-destructive testing, how to improve the quality of the reconstructed image is receiving more and more concern. It is well known that in the existing cone-beam filtered backprojection reconstruction algorithms the cone angle is controlled within a narrow range. The reason of this limitation is the incompleteness of projection data when the cone angle increases. Thus the size of the tested workpiece is limited. Considering the characteristic of X-ray cone angle, an improved cone-beam filtered back-projection reconstruction algorithm taking account of angular correction is proposed in this paper. The aim of our algorithm is to correct the cone-angle effect resulted from the incompleteness of projection data in the conventional algorithm. The basis of the correction is the angular relationship among X-ray source, tested workpiece and the detector. Thus the cone angle is not strictly limited and this algorithm may be used to detect larger workpiece. Further more, adaptive wavelet filter is used to make multiresolution analysis, which can modify the wavelet decomposition series adaptively according to the demand for resolution of local reconstructed area. Therefore the computation and the time of reconstruction can be reduced, and the quality of the reconstructed image can also be improved. (author)

  2. Improving Filtered Backprojection Reconstruction by Data-Dependent Filtering

    NARCIS (Netherlands)

    D.M. Pelt (Daniël); K.J. Batenburg (Joost)

    2014-01-01

    htmlabstractFiltered backprojection, one of the most widely used reconstruction methods in tomography, requires a large number of low-noise projections to yield accurate reconstructions. In many applications of tomography, complete projection data of high quality cannot be obtained, because of

  3. Oral rehabilitation with dental implants and quality of life following mandibular reconstruction with free fibular flap.

    Science.gov (United States)

    Jacobsen, Hans-Christian; Wahnschaff, Falko; Trenkle, Thomas; Sieg, Peter; Hakim, Samer G

    2016-01-01

    Bony reconstruction of jaw defects using the free fibular flap and dental rehabilitation mostly requires insertion of dental implants within the transferred fibula bone. The aim of this paper was to discuss results of the implant stability with data on the possible benefit for the patient's quality of life after such treatment. For clinical outcome of implants, we evaluated 26 patients with a total number of 94 dental implants after a follow-up period of 12 to 132 months. A group of 38 patients who underwent mandibular reconstruction with free fibular flap could be included in the life-quality study. Evaluation included 23 patients with and 15 patients without implant-borne restoration. The quality of life was assessed using the standard QLQ C-30 questionnaire and the H&N35 module of the European Organisation for Research and Treatment of Cancer (EORTC). Of implants, 94.7 % were stable at the time of investigation and could be used for prosthesis. Patients with dental implants reported improvement of life quality along with better scores in most function and symptom scales; however, only values for global health status (QL2), absence of dyspnea (DY) and absence of feeding tube (HNFE) were significantly better than in the control group. Dental implant insertion in fibula grafts along with implant-borne restoration is a proven concept and might lead to improved quality of life following ablative surgery of the jaw. The effect on the quality of life is not as predictable as on the implant stability. Patients with bony defects of the jaw require bony reconstruction. This allows further masticatory rehabilitation using dental implants and might lead to improved quality of life.

  4. Improved proton computed tomography by dual modality image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, David C., E-mail: dch@ki.au.dk; Bassler, Niels [Experimental Clinical Oncology, Aarhus University, 8000 Aarhus C (Denmark); Petersen, Jørgen Breede Baltzer [Medical Physics, Aarhus University Hospital, 8000 Aarhus C (Denmark); Sørensen, Thomas Sangild [Computer Science, Aarhus University, 8000 Aarhus C, Denmark and Clinical Medicine, Aarhus University, 8200 Aarhus N (Denmark)

    2014-03-15

    Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full 360° rotation. In this paper the authors propose a method to overcome the problem using a dual modality reconstruction (DMR) combining the proton data with a cone-beam x-ray prior. Methods: A Catphan 600 phantom was scanned using a cone beam x-ray CT scanner. A digital replica of the phantom was created in the Monte Carlo code Geant4 and a 360° proton CT scan was simulated, storing the entrance and exit position and momentum vector of every proton. Proton CT images were reconstructed using a varying number of angles from the scan. The proton CT images were reconstructed using a constrained nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully sampled case and the 90° interval case, with the MTF = 0.5 (modulation transfer function) ranging from 5.22 to 5.65 linepairs/cm. In the 45° interval case, the MTF = 0.5 dropped to 3.91 linepairs/cm For the fully sampled DMR, the maximal root mean square (RMS) error was 0.006 in units of relative stopping power. For the limited angle cases the maximal RMS error was 0.18, an almost five-fold improvement over the cone beam CT estimate. Conclusions: Dual modality reconstruction yields the high spatial resolution of cone beam x-ray CT while maintaining the improved stopping power estimation of proton CT. In the case of limited angles, the use of prior image proton CT greatly improves the resolution and stopping power estimate, but does not fully achieve the quality of a 360

  5. Improved proton computed tomography by dual modality image reconstruction

    International Nuclear Information System (INIS)

    Hansen, David C.; Bassler, Niels; Petersen, Jørgen Breede Baltzer; Sørensen, Thomas Sangild

    2014-01-01

    Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full 360° rotation. In this paper the authors propose a method to overcome the problem using a dual modality reconstruction (DMR) combining the proton data with a cone-beam x-ray prior. Methods: A Catphan 600 phantom was scanned using a cone beam x-ray CT scanner. A digital replica of the phantom was created in the Monte Carlo code Geant4 and a 360° proton CT scan was simulated, storing the entrance and exit position and momentum vector of every proton. Proton CT images were reconstructed using a varying number of angles from the scan. The proton CT images were reconstructed using a constrained nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully sampled case and the 90° interval case, with the MTF = 0.5 (modulation transfer function) ranging from 5.22 to 5.65 linepairs/cm. In the 45° interval case, the MTF = 0.5 dropped to 3.91 linepairs/cm For the fully sampled DMR, the maximal root mean square (RMS) error was 0.006 in units of relative stopping power. For the limited angle cases the maximal RMS error was 0.18, an almost five-fold improvement over the cone beam CT estimate. Conclusions: Dual modality reconstruction yields the high spatial resolution of cone beam x-ray CT while maintaining the improved stopping power estimation of proton CT. In the case of limited angles, the use of prior image proton CT greatly improves the resolution and stopping power estimate, but does not fully achieve the quality of a 360

  6. High quality digital holographic reconstruction on analog film

    Science.gov (United States)

    Nelsen, B.; Hartmann, P.

    2017-05-01

    High quality real-time digital holographic reconstruction, i.e. at 30 Hz frame rates, has been at the forefront of research and has been hailed as the holy grail of display systems. While these efforts have produced a fascinating array of computer algorithms and technology, many applications of reconstructing high quality digital holograms do not require such high frame rates. In fact, applications such as 3D holographic lithography even require a stationary mask. Typical devices used for digital hologram reconstruction are based on spatial-light-modulator technology and this technology is great for reconstructing arbitrary holograms on the fly; however, it lacks the high spatial resolution achievable by its analog counterpart, holographic film. Analog holographic film is therefore the method of choice for reconstructing highquality static holograms. The challenge lies in taking a static, high-quality digitally calculated hologram and effectively writing it to holographic film. We have developed a theoretical system based on a tunable phase plate, an intensity adjustable high-coherence laser and a slip-stick based piezo rotation stage to effectively produce a digitally calculated hologram on analog film. The configuration reproduces the individual components, both the amplitude and phase, of the hologram in the Fourier domain. These Fourier components are then individually written on the holographic film after interfering with a reference beam. The system is analogous to writing angularly multiplexed plane waves with individual component phase control.

  7. Incomplete projection reconstruction of computed tomography based on the modified discrete algebraic reconstruction technique

    Science.gov (United States)

    Yang, Fuqiang; Zhang, Dinghua; Huang, Kuidong; Gao, Zongzhao; Yang, YaFei

    2018-02-01

    Based on the discrete algebraic reconstruction technique (DART), this study aims to address and test a new improved algorithm applied to incomplete projection data to generate a high quality reconstruction image by reducing the artifacts and noise in computed tomography. For the incomplete projections, an augmented Lagrangian based on compressed sensing is first used in the initial reconstruction for segmentation of the DART to get higher contrast graphics for boundary and non-boundary pixels. Then, the block matching 3D filtering operator was used to suppress the noise and to improve the gray distribution of the reconstructed image. Finally, simulation studies on the polychromatic spectrum were performed to test the performance of the new algorithm. Study results show a significant improvement in the signal-to-noise ratios (SNRs) and average gradients (AGs) of the images reconstructed from incomplete data. The SNRs and AGs of the new images reconstructed by DART-ALBM were on average 30%-40% and 10% higher than the images reconstructed by DART algorithms. Since the improved DART-ALBM algorithm has a better robustness to limited-view reconstruction, which not only makes the edge of the image clear but also makes the gray distribution of non-boundary pixels better, it has the potential to improve image quality from incomplete projections or sparse projections.

  8. CT image quality in sinogram affirmed iterative reconstruction phantom study - is there a point of diminishing returns?

    Energy Technology Data Exchange (ETDEWEB)

    Infante, Juan C. [University of Miami, Department of Radiology, Miami, FL (United States); Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Liu, Yu [Medical College of Wisconsin, Department of Radiology, Milwaukee, WI (United States); Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Pediatrics, Chicago, IL (United States)

    2017-03-15

    In our pediatric practice, we have observed qualitatively limited improvement in the image quality of images generated with sinogram affirmed iterative reconstruction (SAFIRE) compared to series generated with filtered back projection (FBP), particularly in cases near or below a CT dose index volume (CTDI{sub vol}) of 1-mGy. To determine whether the image quality advantage of SAFIRE remains constant across clinically used CT dose levels in an American College of Radiology (ACR) CT accreditation phantom including the lower dose range used in pediatric imaging. An exemption from institutional review board approval was obtained for this phantom-based study. An ACR quality phantom was scanned in incremental kV steps and effective tube current intervals. Acquisitions were reconstructed with FBP and SAFIRE strengths of 1, 3 and 5. Image quality measures were calculated including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), low-contrast resolution and high-contrast resolution. Peak SNR was also calculated. Descriptive and nonparametric statistics were used to compare these image quality metrics while normalizing to CT dose index (CTDI). The percent improvement in SNR and peak SNR of SAFIRE reconstructions compared to FBP decreased from about 70% for image sets acquired above a 1.42 mGy CTDI to 25% at a 0.25 mGy CTDI. CNR improvement with SAFIRE did not vary with dose. No significant difference was seen in the low-contrast resolution or high-contrast resolution of SAFIRE images compared to FBP. SNR did not improve equally after applying SAFIRE across a spectrum clinically used CTDIs. Below a threshold CTDI, the incremental improvement of SAFIRE compared to FBP decreased. (orig.)

  9. Accelerated barrier optimization compressed sensing (ABOCS) for CT reconstruction with improved convergence

    International Nuclear Information System (INIS)

    Niu, Tianye; Fruhauf, Quentin; Petrongolo, Michael; Zhu, Lei; Ye, Xiaojing

    2014-01-01

    Recently, we proposed a new algorithm of accelerated barrier optimization compressed sensing (ABOCS) for iterative CT reconstruction. The previous implementation of ABOCS uses gradient projection (GP) with a Barzilai–Borwein (BB) step-size selection scheme (GP-BB) to search for the optimal solution. The algorithm does not converge stably due to its non-monotonic behavior. In this paper, we further improve the convergence of ABOCS using the unknown-parameter Nesterov (UPN) method and investigate the ABOCS reconstruction performance on clinical patient data. Comparison studies are carried out on reconstructions of computer simulation, a physical phantom and a head-and-neck patient. In all of these studies, the ABOCS results using UPN show more stable and faster convergence than those of the GP-BB method and a state-of-the-art Bregman-type method. As shown in the simulation study of the Shepp–Logan phantom, UPN achieves the same image quality as those of GP-BB and the Bregman-type methods, but reduces the iteration numbers by up to 50% and 90%, respectively. In the Catphan©600 phantom study, a high-quality image with relative reconstruction error (RRE) less than 3% compared to the full-view result is obtained using UPN with 17% projections (60 views). In the conventional filtered-backprojection reconstruction, the corresponding RRE is more than 15% on the same projection data. The superior performance of ABOCS with the UPN implementation is further demonstrated on the head-and-neck patient. Using 25% projections (91 views), the proposed method reduces the RRE from 21% as in the filtered backprojection (FBP) results to 7.3%. In conclusion, we propose UPN for ABOCS implementation. As compared to GP-BB and the Bregman-type methods, the new method significantly improves the convergence with higher stability and fewer iterations. (paper)

  10. Using GRAPPA to improve autocalibrated coil sensitivity estimation for the SENSE family of parallel imaging reconstruction algorithms.

    Science.gov (United States)

    Hoge, W Scott; Brooks, Dana H

    2008-08-01

    Two strategies are widely used in parallel MRI to reconstruct subsampled multicoil image data. SENSE and related methods employ explicit receiver coil spatial response estimates to reconstruct an image. In contrast, coil-by-coil methods such as GRAPPA leverage correlations among the acquired multicoil data to reconstruct missing k-space lines. In self-referenced scenarios, both methods employ Nyquist-rate low-frequency k-space data to identify the reconstruction parameters. Because GRAPPA does not require explicit coil sensitivities estimates, it needs considerably fewer autocalibration signals than SENSE. However, SENSE methods allow greater opportunity to control reconstruction quality though regularization and thus may outperform GRAPPA in some imaging scenarios. Here, we employ GRAPPA to improve self-referenced coil sensitivity estimation in SENSE and related methods using very few auto-calibration signals. This enables one to leverage each methods' inherent strength and produce high quality self-referenced SENSE reconstructions. (c) 2008 Wiley-Liss, Inc.

  11. Improvement on image quality of single photon ECT with converging collimator system

    International Nuclear Information System (INIS)

    Murayama, Hideo; Nohara, Norimasa; Tanaka, Eiichi

    1986-01-01

    Single photon emission computed tomography (SPECT) with converging collimator system was proposed to improve quality of reconstructed images. The collimator system was designed to enhance sensitivity at the center region of field-of-view, where the probability photons escape the attenuating medium is smaller than at the off-center region. In order to evaluate efficiency of the improvement on image quality, the weighting function of projection, which is defined as relative sensitivity to the average on the lateral sampling of projection, was adopted to the image reconstruction algorithm of Radial Post Correction method. Statistical mean square noise in a reconstructed image was formulated in this method. Simulation studies using typical weighting function showed that center-enhanced weighting function brings effective improvement on image quality, especially, at the center region of cold area surrounded by annularly distributed activity. A new SPECT system was proposed as one example of the converging collimator systems. The system is composed of four gamma cameras with four fan-beam collimators, which have different focal distances one another. Simple simulation studies showed that the proposed system has reasonable center-enhanced weighting function, and the image quality based on the proposed system was fairly improved as compared with one based on uniform weighting function at the center region of the field-of-view. (author)

  12. Influence of heart rate on image quality of 64-slice spiral computed coronary angiography and optimization on reconstruction of phase window

    International Nuclear Information System (INIS)

    Luo Xuemao; Lan Yong; Li Wei; Long Wansheng; Zhang Chaotong; Zhong Xiangyang; Yi Lan

    2009-01-01

    Objective: To evaluate the influence of heart rate on the image quality of 64-slice spiral computed coronary angiography (MSCTCA) and optimize the image reconstruction window. Methods: According to the heart rate, 86 patients were classified into 5 groups: group A, the heart rate ≤60 beat per minute(BMP); group B,61-70BMP, group C,71-80BMP, and group D>80BMP. The image quality of MSCTCA was scored 5 grades from 1-5 according to heart motion artifact. The influences of heart rate and reconstruction phase on the image quality of MSCTCA were evaluated. Results: Average heart rate was 64.4 ±10.1BMP. Diagnostic image quality (score>3) was attained in 277 of 344 segments at the best reconstruction interval. There was a significant corxelation between average heart rate and image quality, but there was no difference between relative delay (%) reconstruction and absolute delay (ms) reconstruction on the image quality. Conclusion: Reducing average heart rate is beneficial for improving the image quality. (authors)

  13. Image quality of multiplanar reconstruction of pulmonary CT scans using adaptive statistical iterative reconstruction.

    Science.gov (United States)

    Honda, O; Yanagawa, M; Inoue, A; Kikuyama, A; Yoshida, S; Sumikawa, H; Tobino, K; Koyama, M; Tomiyama, N

    2011-04-01

    We investigated the image quality of multiplanar reconstruction (MPR) using adaptive statistical iterative reconstruction (ASIR). Inflated and fixed lungs were scanned with a garnet detector CT in high-resolution mode (HR mode) or non-high-resolution (HR) mode, and MPR images were then reconstructed. Observers compared 15 MPR images of ASIR (40%) and ASIR (80%) with those of ASIR (0%), and assessed image quality using a visual five-point scale (1, definitely inferior; 5, definitely superior), with particular emphasis on normal pulmonary structures, artefacts, noise and overall image quality. The mean overall image quality scores in HR mode were 3.67 with ASIR (40%) and 4.97 with ASIR (80%). Those in non-HR mode were 3.27 with ASIR (40%) and 3.90 with ASIR (80%). The mean artefact scores in HR mode were 3.13 with ASIR (40%) and 3.63 with ASIR (80%), but those in non-HR mode were 2.87 with ASIR (40%) and 2.53 with ASIR (80%). The mean scores of the other parameters were greater than 3, whereas those in HR mode were higher than those in non-HR mode. There were significant differences between ASIR (40%) and ASIR (80%) in overall image quality (pASIR did not suppress the severe artefacts of contrast medium. In general, MPR image quality with ASIR (80%) was superior to that with ASIR (40%). However, there was an increased incidence of artefacts by ASIR when CT images were obtained in non-HR mode.

  14. Pelvic floor physical therapy: impact on quality of life 6 months after vaginal reconstructive surgery.

    Science.gov (United States)

    Pauls, Rachel N; Crisp, Catrina C; Novicki, Kathleen; Fellner, Angela N; Kleeman, Steven D

    2014-01-01

    Pelvic floor physical therapy (PFPT) is often used as a treatment of pelvic floor disorders and may improve function after pelvic reconstructive surgery. However, the long-term impact of this modality is not understood. This randomized controlled trial compared PFPT to the standard care in women undergoing vaginal reconstruction. The intervention group received PFPT biweekly until 12 weeks postoperatively, in conjunction with a physician assessment. Control subjects underwent a physician assessment alone at all postoperative intervals. The final follow-up was at 24 weeks. Physical examinations (pelvic organ prolapse quantification assessment), intravaginal electromyography, voiding diaries, and validated questionnaires were completed by all subjects. The primary outcome was change in the World Health Organization Quality of Life-BREF. Forty-nine women completed the study, 24 in the PFPT group and 25 in the control group. Although electromyography measures showed better muscular function in PFPT subjects after 12 weeks, at 6 months after surgery, this was no longer noted. However, quality of life parameters improved for the entire sample at 24 weeks, with no difference between groups. Positive change from 12 to 24 weeks was also documented in scores on the Pelvic Floor Distress Inventory-20 (P = 0.04) and Pelvic Floor Impact Questionnaire-7 (P = 0.018), corresponding with continued improvement in bladder symptoms. Finally, Prolapse and Incontinence Sexual Questionnaire-12 and Female Sexual Function Index scores improved between 12 and 24 weeks, suggesting better sexual function overall with time elapsed from surgery. Quality of life improves in all subjects after vaginal reconstructive surgery, with ongoing benefit between 3 and 6 months. Nevertheless, standardized PFPT was not associated with differences at 24 weeks in this cohort of women.

  15. Quality of life before reconstructive breast surgery: A preoperative comparison of patients with immediate, delayed, and major revision reconstruction.

    Science.gov (United States)

    Rosson, Gedge D; Shridharani, Sachin M; Magarakis, Michael; Manahan, Michele A; Basdag, Basak; Gilson, Marta M; Pusic, Andrea L

    2013-05-01

    Women undergo breast reconstruction at different time-points in their cancer care; knowing patients' preoperative quality of life (QoL) is critical in the overall care of the patient with breast cancer. Our objective was to describe presurgical QoL among women undergoing immediate, delayed, or major revision breast reconstructive surgery at our institution. From March 2008 to February 2009, we administered preoperative BREAST-Q questionnaires to women who presented to our institution for breast reconstruction. Univariate and multivariate analyses were performed to compare patient cohorts across multiple QoL domains including body image, physical well-being, psychosocial well-being, and sexual well-being. Of the 231 patients who presented for preoperative consultation, 176 returned the questionnaire (response rate 76%; 117 from the immediate, 21 from the delayed, and 32 from the major revision reconstruction groups, plus 6 mixed or unknown). The three groups differed significantly (P < 0.05) across four of the six domains: body image (satisfaction with breasts), psychosocial well-being, sexual well-being, and physical well-being of the chest and upper body. The immediate reconstruction group had higher (better) scores than the delayed reconstruction group, which had higher (better) scores than the major revision group. These data suggest that women presenting for breast reconstruction at different stages of reconstruction have different baseline QoL. Such data may help us better understand patient selection, education, and expectations, and may lead to improved patient-surgeon communication. Copyright © 2013 Wiley Periodicals, Inc.

  16. A protocol for generating a high-quality genome-scale metabolic reconstruction.

    Science.gov (United States)

    Thiele, Ines; Palsson, Bernhard Ø

    2010-01-01

    Network reconstructions are a common denominator in systems biology. Bottom-up metabolic network reconstructions have been developed over the last 10 years. These reconstructions represent structured knowledge bases that abstract pertinent information on the biochemical transformations taking place within specific target organisms. The conversion of a reconstruction into a mathematical format facilitates a myriad of computational biological studies, including evaluation of network content, hypothesis testing and generation, analysis of phenotypic characteristics and metabolic engineering. To date, genome-scale metabolic reconstructions for more than 30 organisms have been published and this number is expected to increase rapidly. However, these reconstructions differ in quality and coverage that may minimize their predictive potential and use as knowledge bases. Here we present a comprehensive protocol describing each step necessary to build a high-quality genome-scale metabolic reconstruction, as well as the common trials and tribulations. Therefore, this protocol provides a helpful manual for all stages of the reconstruction process.

  17. Predictors of satisfaction and quality of life following post-mastectomy breast reconstruction.

    Science.gov (United States)

    Matthews, Hannah; Carroll, Natalie; Renshaw, Derek; Turner, Andrew; Park, Alan; Skillman, Jo; McCarthy, Kate; Grunfeld, Elizabeth A

    2017-11-01

    Breast reconstruction is associated with multiple psychological benefits. However, few studies have identified clinical and psychological factors associated with improved satisfaction and quality of life. This study examined factors, which predict satisfaction with breast appearance, outcome satisfaction and quality of life following post-mastectomy breast reconstruction. Women who underwent post-mastectomy breast reconstruction between 2010 and 2016 received a postal questionnaire consisting of The BREAST-Q Patient Reported Outcomes Instrument, The European Organisation for Research and Treatment of Cancer QLQ-30 Questionnaire, The Patient and Observer Scar Assessment Scale, and a series of Visual-Analogue Scales. One hundredforty-eight women completed the questionnaire, a 56% response rate. Hierarchical multiple regression analyses revealed psychosocial factors accounted for 75% of the variance in breast satisfaction, 68% for outcome satisfaction, and 46% forquality of life. Psychosocial well-being emerged as a significant predictor of satisfaction with breast appearance (β = .322) and outcome satisfaction (β = .406). Deep inferior epigastric perforator flap patients reported greater satisfaction with breast appearance (β = .120) and outcome satisfaction (β = .167). This study extends beyond the limited research by distinguishing between satisfaction with breast appearance and outcome satisfaction. The study provides evidence for the role of psychosocial factors predicting key patient reported outcomes and demonstrates the importance of psychosocial well-being and reconstruction type. The findings also highlight the need for healthcare providers to consider the psychosocial well-being of patients both preoperatively and post operatively and provide preliminary evidence for the use of deep inferior epigastric perforator reconstructions over other types of reconstructive procedures. Copyright © 2017 John Wiley & Sons, Ltd.

  18. The quality of reconstructed 3D images in multidetector-row helical CT: experimental study involving scan parameters

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Lee, Ho Kyu; Choi, Choong Gon; Suh, Dae Chul; Lim, Tae Hwan; Kang, Weechang

    2002-01-01

    To determine which multidetector-row helical CT scanning technique provides the best-quality reconstructed 3D images, and to assess differences in image quality according to the levels of the scanning parameters used. Four objects with different surfaces and contours were scanned using multidetector-row helical CT at three detector-row collimations (1.25, 2.50, 5.00 mm), two pitches (3.0, 6.0), and three different degrees of overlap between the reconstructed slices (0%, 25%, 50%). Reconstructed 3D images of the resulting 72 sets of data were produced using volumetric rendering. The 72 images were graded on a scale from 1 (worst) to 5 (best) for each of four rating criteria, giving a mean score for each criterion and an overall mean score. Statistical analysis was used to assess differences in image quality according to scanning parameter levels. The mean score for each rating criterion, and the overall mean score, varied significantly according to the scanning parameter levels used. With regard to detector-row collimation and pitch, all levels of scanning parameters gave rise to significant differences, while in the degree of overlap of reconstructed slices, there were significant differences between overlap of 0% and of 50% in all levels of scanning parameters, and between overlap of 25% and of 50% in overall accuracy and overall mean score. Among the 18 scanning sequences, the highest score (4.94) was achieved with 1.25 mm detector-row collimation, 3.0 pitch, and 50% overlap between reconstructed slices. Comparison of the quality of reconstructed 3D images obtained using multidetector-row helical CT and various scanning techniques indicated that the 1.25 mm, 3.0, 50% scanning sequence was best. Quality improved as detector-row collimation decreased; as pitch was reduced from 6.0 to 3.0; and as overlap between reconstructed slices increased

  19. iCN718, an Updated and Improved Genome-Scale Metabolic Network Reconstruction of Acinetobacter baumannii AYE.

    Science.gov (United States)

    Norsigian, Charles J; Kavvas, Erol; Seif, Yara; Palsson, Bernhard O; Monk, Jonathan M

    2018-01-01

    Acinetobacter baumannii has become an urgent clinical threat due to the recent emergence of multi-drug resistant strains. There is thus a significant need to discover new therapeutic targets in this organism. One means for doing so is through the use of high-quality genome-scale reconstructions. Well-curated and accurate genome-scale models (GEMs) of A. baumannii would be useful for improving treatment options. We present an updated and improved genome-scale reconstruction of A. baumannii AYE, named iCN718, that improves and standardizes previous A. baumannii AYE reconstructions. iCN718 has 80% accuracy for predicting gene essentiality data and additionally can predict large-scale phenotypic data with as much as 89% accuracy, a new capability for an A. baumannii reconstruction. We further demonstrate that iCN718 can be used to analyze conserved metabolic functions in the A. baumannii core genome and to build strain-specific GEMs of 74 other A. baumannii strains from genome sequence alone. iCN718 will serve as a resource to integrate and synthesize new experimental data being generated for this urgent threat pathogen.

  20. Improving Conductivity Image Quality Using Block Matrix-based Multiple Regularization (BMMR Technique in EIT: A Simulation Study

    Directory of Open Access Journals (Sweden)

    Tushar Kanti Bera

    2011-06-01

    Full Text Available A Block Matrix based Multiple Regularization (BMMR technique is proposed for improving conductivity image quality in EIT. The response matrix (JTJ has been partitioned into several sub-block matrices and the highest eigenvalue of each sub-block matrices has been chosen as regularization parameter for the nodes contained by that sub-block. Simulated boundary data are generated for circular domain with circular inhomogeneity and the conductivity images are reconstructed in a Model Based Iterative Image Reconstruction (MoBIIR algorithm. Conductivity images are reconstructed with BMMR technique and the results are compared with the Single-step Tikhonov Regularization (STR and modified Levenberg-Marquardt Regularization (LMR methods. It is observed that the BMMR technique reduces the projection error and solution error and improves the conductivity reconstruction in EIT. Result show that the BMMR method also improves the image contrast and inhomogeneity conductivity profile and hence the reconstructed image quality is enhanced. ;doi:10.5617/jeb.170 J Electr Bioimp, vol. 2, pp. 33-47, 2011

  1. The effects of slice thickness and reconstructive parameters on VR image quality in multi-slice CT

    International Nuclear Information System (INIS)

    Gao Zhenlong; Wang Qiang; Liu Caixia

    2005-01-01

    Objective: To explore the effects of slice thickness, reconstructive thickness and reconstructive interval on VR image quality in multi-slice CT, in order to select the best slice thickness and reconstructive parameters for the imaging. Methods: Multi-slice CT scan was applied on a rubber dinosaur model with different slice thickness. VR images were reconstructed with different reconstructive thickness and reconstructive interval. Five radiologists were invited to evaluate the quality of the images without knowing anything about the parameters. Results: The slice thickness, reconstructive thickness and reconstructive interval did have effects on VR image quality and the effective degree was different. The effective coefficients were V 1 =1413.033, V 2 =563.733, V 3 =390.533, respectively. The parameters interacted with the others (P<0.05). The smaller of those parameters, the better of the image quality. With a small slice thickness and a reconstructive slice equal to slice thickness, the image quality had no obvious difference when the reconstructive interval was 1/2, 1/3, 1/4 of the slice thickness. Conclusion: A relative small scan slice thickness, a reconstructive slice equal to slice thickness and a reconstructive interval 1/2 of the slice thickness should be selected for the best VR image quality. The image quality depends mostly on the slice thickness. (authors)

  2. Can use of adaptive statistical iterative reconstruction reduce radiation dose in unenhanced head CT? An analysis of qualitative and quantitative image quality

    International Nuclear Information System (INIS)

    Østerås, Bjørn Helge; Heggen, Kristin Livelten; Pedersen, Hans Kristian; Andersen, Hilde Kjernlie; Martinsen, Anne Catrine T

    2016-01-01

    Iterative reconstruction can reduce image noise and thereby facilitate dose reduction. To evaluate qualitative and quantitative image quality for full dose and dose reduced head computed tomography (CT) protocols reconstructed using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR). Fourteen patients undergoing follow-up head CT were included. All patients underwent full dose (FD) exam and subsequent 15% dose reduced (DR) exam, reconstructed using FBP and 30% ASIR. Qualitative image quality was assessed using visual grading characteristics. Quantitative image quality was assessed using ROI measurements in cerebrospinal fluid (CSF), white matter, peripheral and central gray matter. Additionally, quantitative image quality was measured in Catphan and vendor’s water phantom. There was no significant difference in qualitative image quality between FD FBP and DR ASIR. Comparing same scan FBP versus ASIR, a noise reduction of 28.6% in CSF and between −3.7 and 3.5% in brain parenchyma was observed. Comparing FD FBP versus DR ASIR, a noise reduction of 25.7% in CSF, and −7.5 and 6.3% in brain parenchyma was observed. Image contrast increased in ASIR reconstructions. Contrast-to-noise ratio was improved in DR ASIR compared to FD FBP. In phantoms, noise reduction was in the range of 3 to 28% with image content. There was no significant difference in qualitative image quality between full dose FBP and dose reduced ASIR. CNR improved in DR ASIR compared to FD FBP mostly due to increased contrast, not reduced noise. Therefore, we recommend using caution if reducing dose and applying ASIR to maintain image quality

  3. Dual-source CT coronary imaging in heart transplant recipients: image quality and optimal reconstruction interval

    International Nuclear Information System (INIS)

    Bastarrika, Gorka; Arraiza, Maria; Pueyo, Jesus C.; Cecco, Carlo N. de; Ubilla, Matias; Mastrobuoni, Stefano; Rabago, Gregorio

    2008-01-01

    The image quality and optimal reconstruction interval for coronary arteries in heart transplant recipients undergoing non-invasive dual-source computed tomography (DSCT) coronary angiography was evaluated. Twenty consecutive heart transplant recipients who underwent DSCT coronary angiography were included (19 male, one female; mean age 63.1±10.7 years). Data sets were reconstructed in 5% steps from 30% to 80% of the R-R interval. Two blinded independent observers assessed the image quality of each coronary segments using a five-point scale (from 0 = not evaluative to 4=excellent quality). A total of 289 coronary segments in 20 heart transplant recipients were evaluated. Mean heart rate during the scan was 89.1±10.4 bpm. At the best reconstruction interval, diagnostic image quality (score ≥2) was obtained in 93.4% of the coronary segments (270/289) with a mean image quality score of 3.04± 0.63. Systolic reconstruction intervals provided better image quality scores than diastolic reconstruction intervals (overall mean quality scores obtained with the systolic and diastolic reconstructions 3.03±1.06 and 2.73±1.11, respectively; P<0.001). Different systolic reconstruction intervals (35%, 40%, 45% of RR interval) did not yield to significant differences in image quality scores for the coronary segments (P=0.74). Reconstructions obtained at the systolic phase of the cardiac cycle allowed excellent diagnostic image quality coronary angiograms in heart transplant recipients undergoing DSCT coronary angiography. (orig.)

  4. Image quality in thoracic 4D cone-beam CT: A sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing

    International Nuclear Information System (INIS)

    Shieh, Chun-Chien; Kipritidis, John; O’Brien, Ricky T.; Keall, Paul J.; Kuncic, Zdenka

    2014-01-01

    Purpose: Respiratory signal, binning method, and reconstruction algorithm are three major controllable factors affecting image quality in thoracic 4D cone-beam CT (4D-CBCT), which is widely used in image guided radiotherapy (IGRT). Previous studies have investigated each of these factors individually, but no integrated sensitivity analysis has been performed. In addition, projection angular spacing is also a key factor in reconstruction, but how it affects image quality is not obvious. An investigation of the impacts of these four factors on image quality can help determine the most effective strategy in improving 4D-CBCT for IGRT. Methods: Fourteen 4D-CBCT patient projection datasets with various respiratory motion features were reconstructed with the following controllable factors: (i) respiratory signal (real-time position management, projection image intensity analysis, or fiducial marker tracking), (ii) binning method (phase, displacement, or equal-projection-density displacement binning), and (iii) reconstruction algorithm [Feldkamp–Davis–Kress (FDK), McKinnon–Bates (MKB), or adaptive-steepest-descent projection-onto-convex-sets (ASD-POCS)]. The image quality was quantified using signal-to-noise ratio (SNR), contrast-to-noise ratio, and edge-response width in order to assess noise/streaking and blur. The SNR values were also analyzed with respect to the maximum, mean, and root-mean-squared-error (RMSE) projection angular spacing to investigate how projection angular spacing affects image quality. Results: The choice of respiratory signals was found to have no significant impact on image quality. Displacement-based binning was found to be less prone to motion artifacts compared to phase binning in more than half of the cases, but was shown to suffer from large interbin image quality variation and large projection angular gaps. Both MKB and ASD-POCS resulted in noticeably improved image quality almost 100% of the time relative to FDK. In addition, SNR

  5. Image quality in thoracic 4D cone-beam CT: A sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing

    Energy Technology Data Exchange (ETDEWEB)

    Shieh, Chun-Chien [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, NSW 2006, Australia and Institute of Medical Physics, School of Physics, University of Sydney, NSW 2006 (Australia); Kipritidis, John; O’Brien, Ricky T.; Keall, Paul J., E-mail: paul.keall@sydney.edu.au [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, NSW 2006 (Australia); Kuncic, Zdenka [Institute of Medical Physics, School of Physics, University of Sydney, NSW 2006 (Australia)

    2014-04-15

    Purpose: Respiratory signal, binning method, and reconstruction algorithm are three major controllable factors affecting image quality in thoracic 4D cone-beam CT (4D-CBCT), which is widely used in image guided radiotherapy (IGRT). Previous studies have investigated each of these factors individually, but no integrated sensitivity analysis has been performed. In addition, projection angular spacing is also a key factor in reconstruction, but how it affects image quality is not obvious. An investigation of the impacts of these four factors on image quality can help determine the most effective strategy in improving 4D-CBCT for IGRT. Methods: Fourteen 4D-CBCT patient projection datasets with various respiratory motion features were reconstructed with the following controllable factors: (i) respiratory signal (real-time position management, projection image intensity analysis, or fiducial marker tracking), (ii) binning method (phase, displacement, or equal-projection-density displacement binning), and (iii) reconstruction algorithm [Feldkamp–Davis–Kress (FDK), McKinnon–Bates (MKB), or adaptive-steepest-descent projection-onto-convex-sets (ASD-POCS)]. The image quality was quantified using signal-to-noise ratio (SNR), contrast-to-noise ratio, and edge-response width in order to assess noise/streaking and blur. The SNR values were also analyzed with respect to the maximum, mean, and root-mean-squared-error (RMSE) projection angular spacing to investigate how projection angular spacing affects image quality. Results: The choice of respiratory signals was found to have no significant impact on image quality. Displacement-based binning was found to be less prone to motion artifacts compared to phase binning in more than half of the cases, but was shown to suffer from large interbin image quality variation and large projection angular gaps. Both MKB and ASD-POCS resulted in noticeably improved image quality almost 100% of the time relative to FDK. In addition, SNR

  6. Anisotropic modeling and joint-MAP stitching for improved ultrasound model-based iterative reconstruction of large and thick specimens

    Energy Technology Data Exchange (ETDEWEB)

    Almansouri, Hani [Purdue University; Venkatakrishnan, Singanallur V. [ORNL; Clayton, Dwight A. [ORNL; Polsky, Yarom [ORNL; Bouman, Charles [Purdue University; Santos-Villalobos, Hector J. [ORNL

    2018-04-01

    One-sided non-destructive evaluation (NDE) is widely used to inspect materials, such as concrete structures in nuclear power plants (NPP). A widely used method for one-sided NDE is the synthetic aperture focusing technique (SAFT). The SAFT algorithm produces reasonable results when inspecting simple structures. However, for complex structures, such as heavily reinforced thick concrete structures, SAFT results in artifacts and hence there is a need for a more sophisticated inversion technique. Model-based iterative reconstruction (MBIR) algorithms, which are typically equivalent to regularized inversion techniques, offer a powerful framework to incorporate complex models for the physics, detector miscalibrations and the materials being imaged to obtain high quality reconstructions. Previously, we have proposed an ultrasonic MBIR method that signifcantly improves reconstruction quality compared to SAFT. However, the method made some simplifying assumptions on the propagation model and did not disucss ways to handle data that is obtained by raster scanning a system over a surface to inspect large regions. In this paper, we propose a novel MBIR algorithm that incorporates an anisotropic forward model and allows for the joint processing of data obtained from a system that raster scans a large surface. We demonstrate that the new MBIR method can produce dramatic improvements in reconstruction quality compared to SAFT and suppresses articfacts compared to the perviously presented MBIR approach.

  7. Adaptive Statistical Iterative Reconstruction-V Versus Adaptive Statistical Iterative Reconstruction: Impact on Dose Reduction and Image Quality in Body Computed Tomography.

    Science.gov (United States)

    Gatti, Marco; Marchisio, Filippo; Fronda, Marco; Rampado, Osvaldo; Faletti, Riccardo; Bergamasco, Laura; Ropolo, Roberto; Fonio, Paolo

    The aim of this study was to evaluate the impact on dose reduction and image quality of the new iterative reconstruction technique: adaptive statistical iterative reconstruction (ASIR-V). Fifty consecutive oncologic patients acted as case controls undergoing during their follow-up a computed tomography scan both with ASIR and ASIR-V. Each study was analyzed in a double-blinded fashion by 2 radiologists. Both quantitative and qualitative analyses of image quality were conducted. Computed tomography scanner radiation output was 38% (29%-45%) lower (P ASIR-V examinations than for the ASIR ones. The quantitative image noise was significantly lower (P ASIR-V. Adaptive statistical iterative reconstruction-V had a higher performance for the subjective image noise (P = 0.01 for 5 mm and P = 0.009 for 1.25 mm), the other parameters (image sharpness, diagnostic acceptability, and overall image quality) being similar (P > 0.05). Adaptive statistical iterative reconstruction-V is a new iterative reconstruction technique that has the potential to provide image quality equal to or greater than ASIR, with a dose reduction around 40%.

  8. Image quality of ct angiography using model-based iterative reconstruction in infants with congenital heart disease: Comparison with filtered back projection and hybrid iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Qianjun, E-mail: jiaqianjun@126.com [Southern Medical University, Guangzhou, Guangdong (China); Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Department of Catheterization Lab, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Zhuang, Jian, E-mail: zhuangjian5413@tom.com [Department of Cardiac Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Jiang, Jun, E-mail: 81711587@qq.com [Department of Radiology, Shenzhen Second People’s Hospital, Shenzhen, Guangdong (China); Li, Jiahua, E-mail: 970872804@qq.com [Department of Catheterization Lab, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Huang, Meiping, E-mail: huangmeiping_vip@163.com [Department of Catheterization Lab, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Southern Medical University, Guangzhou, Guangdong (China); Liang, Changhong, E-mail: cjr.lchh@vip.163.com [Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Southern Medical University, Guangzhou, Guangdong (China)

    2017-01-15

    Purpose: To compare the image quality, rate of coronary artery visualization and diagnostic accuracy of 256-slice multi-detector computed tomography angiography (CTA) with prospective electrocardiographic (ECG) triggering at a tube voltage of 80 kVp between 3 reconstruction algorithms (filtered back projection (FBP), hybrid iterative reconstruction (iDose{sup 4}) and iterative model reconstruction (IMR)) in infants with congenital heart disease (CHD). Methods: Fifty-one infants with CHD who underwent cardiac CTA in our institution between December 2014 and March 2015 were included. The effective radiation doses were calculated. Imaging data were reconstructed using the FBP, iDose{sup 4} and IMR algorithms. Parameters of objective image quality (noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)); subjective image quality (overall image quality, image noise and margin sharpness); coronary artery visibility; and diagnostic accuracy for the three algorithms were measured and compared. Results: The mean effective radiation dose was 0.61 ± 0.32 mSv. Compared to FBP and iDose{sup 4}, IMR yielded significantly lower noise (P < 0.01), higher SNR and CNR values (P < 0.01), and a greater subjective image quality score (P < 0.01). The total number of coronary segments visualized was significantly higher for both iDose{sup 4} and IMR than for FBP (P = 0.002 and P = 0.025, respectively), but there was no significant difference in this parameter between iDose{sup 4} and IMR (P = 0.397). There was no significant difference in the diagnostic accuracy between the FBP, iDose{sup 4} and IMR algorithms (χ{sup 2} = 0.343, P = 0.842). Conclusions: For infants with CHD undergoing cardiac CTA, the IMR reconstruction algorithm provided significantly increased objective and subjective image quality compared with the FBP and iDose{sup 4} algorithms. However, IMR did not improve the diagnostic accuracy or coronary artery visualization compared with iDose{sup 4}.

  9. Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

    Energy Technology Data Exchange (ETDEWEB)

    Rohkohl, Christopher; Bruder, Herbert; Stierstorfer, Karl [Siemens AG, Healthcare Sector, Siemensstrasse 1, 91301 Forchheim (Germany); Flohr, Thomas [Siemens AG, Healthcare Sector, Siemensstrasse 1, 91301 Forchheim (Germany); Institute of Diagnostic Radiology, Eberhard Karls University, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)

    2013-03-15

    Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum

  10. Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

    International Nuclear Information System (INIS)

    Rohkohl, Christopher; Bruder, Herbert; Stierstorfer, Karl; Flohr, Thomas

    2013-01-01

    Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum

  11. Cranial CT with adaptive statistical iterative reconstruction: improved image quality with concomitant radiation dose reduction.

    Science.gov (United States)

    Rapalino, O; Kamalian, Shervin; Kamalian, Shahmir; Payabvash, S; Souza, L C S; Zhang, D; Mukta, J; Sahani, D V; Lev, M H; Pomerantz, S R

    2012-04-01

    To safeguard patient health, there is great interest in CT radiation-dose reduction. The purpose of this study was to evaluate the impact of an iterative-reconstruction algorithm, ASIR, on image-quality measures in reduced-dose head CT scans for adult patients. Using a 64-section scanner, we analyzed 100 reduced-dose adult head CT scans at 6 predefined levels of ASIR blended with FBP reconstruction. These scans were compared with 50 CT scans previously obtained at a higher routine dose without ASIR reconstruction. SNR and CNR were computed from Hounsfield unit measurements of normal GM and WM of brain parenchyma. A blinded qualitative analysis was performed in 10 lower-dose CT datasets compared with higher-dose ones without ASIR. Phantom data analysis was also performed. Lower-dose scans without ASIR had significantly lower mean GM and WM SNR (P = .003) and similar GM-WM CNR values compared with higher routine-dose scans. However, at ASIR levels of 20%-40%, there was no statistically significant difference in SNR, and at ASIR levels of ≥60%, the SNR values of the reduced-dose scans were significantly higher (P ASIR levels of ≥40% (P ASIR levels ≥60% (P ASIR in adult head CT scans reduces image noise and increases low-contrast resolution, while allowing lower radiation doses without affecting spatial resolution.

  12. Use of a hybrid iterative reconstruction technique to reduce image noise and improve image quality in obese patients undergoing computed tomographic pulmonary angiography.

    Science.gov (United States)

    Kligerman, Seth; Mehta, Dhruv; Farnadesh, Mahmmoudreza; Jeudy, Jean; Olsen, Kathryn; White, Charles

    2013-01-01

    To determine whether an iterative reconstruction (IR) technique (iDose, Philips Healthcare) can reduce image noise and improve image quality in obese patients undergoing computed tomographic pulmonary angiography (CTPA). The study was Health Insurance Portability and Accountability Act compliant and approved by our institutional review board. A total of 33 obese patients (average body mass index: 42.7) underwent CTPA studies following standard departmental protocols. The data were reconstructed with filtered back projection (FBP) and 3 iDose strengths (iDoseL1, iDoseL3, and iDoseL5) for a total of 132 studies. FBP data were collected from 33 controls (average body mass index: 22) undergoing CTPA. Regions of interest were drawn at 6 identical levels in the pulmonary artery (PA), from the main PA to a subsegmental branch, in both the control group and study groups using each algorithm. Noise and attenuation were measured at all PA levels. Three thoracic radiologists graded each study on a scale of 1 (very poor) to 5 (ideal) by 4 categories: image quality, noise, PA enhancement, and "plastic" appearance. Statistical analysis was performed using an unpaired t test, 1-way analysis of variance, and linear weighted κ. Compared with the control group, there was significantly higher noise with FBP, iDoseL1, and iDoseL3 algorithms (Pnoise in the control group and iDoseL5 algorithm in the study group. Analysis within the study group showed a significant and progressive decrease in noise and increase in the contrast-to-noise ratio as the level of IR was increased (Pnoise and PA enhancement with increasing levels of iDose. The use of an IR technique leads to qualitative and quantitative improvements in image noise and image quality in obese patients undergoing CTPA.

  13. CT reconstruction techniques for improved accuracy of lung CT airway measurement

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, A. [Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53705 (United States); Ranallo, F. N. [Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53705 and Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53792 (United States); Judy, P. F. [Brigham and Women’s Hospital, Boston, Massachusetts 02115 (United States); Gierada, D. S. [Department of Radiology, Washington University, St. Louis, Missouri 63110 (United States); Fain, S. B., E-mail: sfain@wisc.edu [Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53705 (United States); Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53792 (United States); Department of Biomedical Engineering,University of Wisconsin School of Engineering, Madison, Wisconsin 53706 (United States)

    2014-11-01

    Purpose: To determine the impact of constrained reconstruction techniques on quantitative CT (qCT) of the lung parenchyma and airways for low x-ray radiation dose. Methods: Measurement of small airways with qCT remains a challenge, especially for low x-ray dose protocols. Images of the COPDGene quality assurance phantom (CTP698, The Phantom Laboratory, Salem, NY) were obtained using a GE discovery CT750 HD scanner for helical scans at x-ray radiation dose-equivalents ranging from 1 to 4.12 mSv (12–100 mA s current–time product). Other parameters were 40 mm collimation, 0.984 pitch, 0.5 s rotation, and 0.625 mm thickness. The phantom was sandwiched between 7.5 cm thick water attenuating phantoms for a total length of 20 cm to better simulate the scatter conditions of patient scans. Image data sets were reconstructed using STANDARD (STD), DETAIL, BONE, and EDGE algorithms for filtered back projection (FBP), 100% adaptive statistical iterative reconstruction (ASIR), and Veo reconstructions. Reduced (half) display field of view (DFOV) was used to increase sampling across airway phantom structures. Inner diameter (ID), wall area percent (WA%), and wall thickness (WT) measurements of eight airway mimicking tubes in the phantom, including a 2.5 mm ID (42.6 WA%, 0.4 mm WT), 3 mm ID (49.0 WA%, 0.6 mm WT), and 6 mm ID (49.0 WA%, 1.2 mm WT) were performed with Airway Inspector (Surgical Planning Laboratory, Brigham and Women’s Hospital, Boston, MA) using the phase congruency edge detection method. The average of individual measures at five central slices of the phantom was taken to reduce measurement error. Results: WA% measures were greatly overestimated while IDs were underestimated for the smaller airways, especially for reconstructions at full DFOV (36 cm) using the STD kernel, due to poor sampling and spatial resolution (0.7 mm pixel size). Despite low radiation dose, the ID of the 6 mm ID airway was consistently measured accurately for all methods other than STD

  14. CT reconstruction techniques for improved accuracy of lung CT airway measurement

    International Nuclear Information System (INIS)

    Rodriguez, A.; Ranallo, F. N.; Judy, P. F.; Gierada, D. S.; Fain, S. B.

    2014-01-01

    Purpose: To determine the impact of constrained reconstruction techniques on quantitative CT (qCT) of the lung parenchyma and airways for low x-ray radiation dose. Methods: Measurement of small airways with qCT remains a challenge, especially for low x-ray dose protocols. Images of the COPDGene quality assurance phantom (CTP698, The Phantom Laboratory, Salem, NY) were obtained using a GE discovery CT750 HD scanner for helical scans at x-ray radiation dose-equivalents ranging from 1 to 4.12 mSv (12–100 mA s current–time product). Other parameters were 40 mm collimation, 0.984 pitch, 0.5 s rotation, and 0.625 mm thickness. The phantom was sandwiched between 7.5 cm thick water attenuating phantoms for a total length of 20 cm to better simulate the scatter conditions of patient scans. Image data sets were reconstructed using STANDARD (STD), DETAIL, BONE, and EDGE algorithms for filtered back projection (FBP), 100% adaptive statistical iterative reconstruction (ASIR), and Veo reconstructions. Reduced (half) display field of view (DFOV) was used to increase sampling across airway phantom structures. Inner diameter (ID), wall area percent (WA%), and wall thickness (WT) measurements of eight airway mimicking tubes in the phantom, including a 2.5 mm ID (42.6 WA%, 0.4 mm WT), 3 mm ID (49.0 WA%, 0.6 mm WT), and 6 mm ID (49.0 WA%, 1.2 mm WT) were performed with Airway Inspector (Surgical Planning Laboratory, Brigham and Women’s Hospital, Boston, MA) using the phase congruency edge detection method. The average of individual measures at five central slices of the phantom was taken to reduce measurement error. Results: WA% measures were greatly overestimated while IDs were underestimated for the smaller airways, especially for reconstructions at full DFOV (36 cm) using the STD kernel, due to poor sampling and spatial resolution (0.7 mm pixel size). Despite low radiation dose, the ID of the 6 mm ID airway was consistently measured accurately for all methods other than STD

  15. Cardiac CT for planning redo cardiac surgery: effect of knowledge-based iterative model reconstruction on image quality

    International Nuclear Information System (INIS)

    Oda, Seitaro; Weissman, Gaby; Weigold, W. Guy; Vembar, Mani

    2015-01-01

    The purpose of this study was to investigate the effects of knowledge-based iterative model reconstruction (IMR) on image quality in cardiac CT performed for the planning of redo cardiac surgery by comparing IMR images with images reconstructed with filtered back-projection (FBP) and hybrid iterative reconstruction (HIR). We studied 31 patients (23 men, 8 women; mean age 65.1 ± 16.5 years) referred for redo cardiac surgery who underwent cardiac CT. Paired image sets were created using three types of reconstruction: FBP, HIR, and IMR. Quantitative parameters including CT attenuation, image noise, and contrast-to-noise ratio (CNR) of each cardiovascular structure were calculated. The visual image quality - graininess, streak artefact, margin sharpness of each cardiovascular structure, and overall image quality - was scored on a five-point scale. The mean image noise of FBP, HIR, and IMR images was 58.3 ± 26.7, 36.0 ± 12.5, and 14.2 ± 5.5 HU, respectively; there were significant differences in all comparison combinations among the three methods. The CNR of IMR images was better than that of FBP and HIR images in all evaluated structures. The visual scores were significantly higher for IMR than for the other images in all evaluated parameters. IMR can provide significantly improved qualitative and quantitative image quality at in cardiac CT for planning of reoperative cardiac surgery. (orig.)

  16. Path integration guided with a quality map for shape reconstruction in the fringe reflection technique

    Science.gov (United States)

    Jing, Xiaoli; Cheng, Haobo; Wen, Yongfu

    2018-04-01

    A new local integration algorithm called quality map path integration (QMPI) is reported for shape reconstruction in the fringe reflection technique. A quality map is proposed to evaluate the quality of gradient data locally, and functions as a guideline for the integrated path. The presented method can be employed in wavefront estimation from its slopes over the general shaped surface with slope noise equivalent to that in practical measurements. Moreover, QMPI is much better at handling the slope data with local noise, which may be caused by the irregular shapes of the surface under test. The performance of QMPI is discussed by simulations and experiment. It is shown that QMPI not only improves the accuracy of local integration, but can also be easily implemented with no iteration compared to Southwell zonal reconstruction (SZR). From an engineering point-of-view, the proposed method may also provide an efficient and stable approach for different shapes with high-precise demand.

  17. Image quality at low tube voltage (70 kV) and sinogram-affirmed iterative reconstruction for computed tomography in infants with congenital heart disease

    International Nuclear Information System (INIS)

    Nakagawa, Motoo; Ozawa, Yoshiyuki; Sakurai, Keita; Shimohira, Masashi; Shibamoto, Yuta; Ohashi, Kazuya; Asano, Miki; Yamaguchi, Sachiko

    2015-01-01

    Lower tube voltage has advantages for CT angiography, such as improved contrast To evaluate the image quality of low-voltage (70 kV) CT for congenital heart disease and the ability of sinogram-affirmed iterative reconstruction to improve image quality. Forty-six children with congenital heart disease (median age: 109 days) were examined using dual-source CT. Scans were performed at 80 kV and 70 kV in 21 and 25 children, respectively. A nonionic iodinated contrast medium (300 mg I/ml) was used for the 80-kV protocol. The contrast medium was diluted to 75% (225 mgI/mL) with saline for the 70-kV protocol. Image noise was measured in the two protocols for each group by extracting the standard deviations of a region of interest placed on the descending aorta. We then determined whether sinogram-affirmed iterative reconstruction reduced the image noise at 70 kV. There was more noise at 70 kV than at 80 kV (29 ± 12 vs 20 ± 4.8; P < 0.01). Sinogram-affirmed iterative reconstruction with grade 4 strength settings improved the noise (20 ± 5.9; P < 0.01) for the 70-kV group. Sinogram-affirmed iterative reconstruction improved the image quality of CT in congenital heart disease. (orig.)

  18. Image quality at low tube voltage (70 kV) and sinogram-affirmed iterative reconstruction for computed tomography in infants with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Motoo; Ozawa, Yoshiyuki; Sakurai, Keita; Shimohira, Masashi; Shibamoto, Yuta [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, Nagoya (Japan); Ohashi, Kazuya [Nagoya City University Hospital, Division of Central Radiology, Nagoya (Japan); Asano, Miki [Nagoya City University Graduate School of Medical Sciences, Department of Cardiovascular Surgery, Nagoya (Japan); Yamaguchi, Sachiko [Nagoya City University Graduate School of Medical Sciences, Department of Pediatrics and Neonatology, Nagoya (Japan)

    2015-09-15

    Lower tube voltage has advantages for CT angiography, such as improved contrast To evaluate the image quality of low-voltage (70 kV) CT for congenital heart disease and the ability of sinogram-affirmed iterative reconstruction to improve image quality. Forty-six children with congenital heart disease (median age: 109 days) were examined using dual-source CT. Scans were performed at 80 kV and 70 kV in 21 and 25 children, respectively. A nonionic iodinated contrast medium (300 mg I/ml) was used for the 80-kV protocol. The contrast medium was diluted to 75% (225 mgI/mL) with saline for the 70-kV protocol. Image noise was measured in the two protocols for each group by extracting the standard deviations of a region of interest placed on the descending aorta. We then determined whether sinogram-affirmed iterative reconstruction reduced the image noise at 70 kV. There was more noise at 70 kV than at 80 kV (29 ± 12 vs 20 ± 4.8; P < 0.01). Sinogram-affirmed iterative reconstruction with grade 4 strength settings improved the noise (20 ± 5.9; P < 0.01) for the 70-kV group. Sinogram-affirmed iterative reconstruction improved the image quality of CT in congenital heart disease. (orig.)

  19. Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR).

    Science.gov (United States)

    Notohamiprodjo, S; Deak, Z; Meurer, F; Maertz, F; Mueck, F G; Geyer, L L; Wirth, S

    2015-01-01

    The purpose of this study was to compare cranial CT (CCT) image quality (IQ) of the MBIR algorithm with standard iterative reconstruction (ASiR). In this institutional review board (IRB)-approved study, raw data sets of 100 unenhanced CCT examinations (120 kV, 50-260 mAs, 20 mm collimation, 0.984 pitch) were reconstructed with both ASiR and MBIR. Signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated from attenuation values measured in caudate nucleus, frontal white matter, anterior ventricle horn, fourth ventricle, and pons. Two radiologists, who were blinded to the reconstruction algorithms, evaluated anonymized multiplanar reformations of 2.5 mm with respect to depiction of different parenchymal structures and impact of artefacts on IQ with a five-point scale (0: unacceptable, 1: less than average, 2: average, 3: above average, 4: excellent). MBIR decreased artefacts more effectively than ASiR (p ASiR was 2 (p ASiR (p ASiR. As CCT is an examination that is frequently required, the use of MBIR may allow for substantial reduction of radiation exposure caused by medical diagnostics. • Model-Based iterative reconstruction (MBIR) effectively decreased artefacts in cranial CT. • MBIR reconstructed images were rated with significantly higher scores for image quality. • Model-Based iterative reconstruction may allow reduced-dose diagnostic examination protocols.

  20. Synthesis method from low-coherence digital holograms for improvement of image quality in holographic display.

    Science.gov (United States)

    Mori, Yutaka; Nomura, Takanori

    2013-06-01

    In holographic displays, it is undesirable to observe the speckle noises with the reconstructed images. A method for improvement of reconstructed image quality by synthesizing low-coherence digital holograms is proposed. It is possible to obtain speckleless reconstruction of holograms due to low-coherence digital holography. An image sensor records low-coherence digital holograms, and the holograms are synthesized by computational calculation. Two approaches, the threshold-processing and the picking-a-peak methods, are proposed in order to reduce random noise of low-coherence digital holograms. The reconstructed image quality by the proposed methods is compared with the case of high-coherence digital holography. Quantitative evaluation is given to confirm the proposed methods. In addition, the visual evaluation by 15 people is also shown.

  1. Patient involvement in the decision-making process improves satisfaction and quality of life in postmastectomy breast reconstruction.

    Science.gov (United States)

    Ashraf, Azra A; Colakoglu, Salih; Nguyen, John T; Anastasopulos, Alexandra J; Ibrahim, Ahmed M S; Yueh, Janet H; Lin, Samuel J; Tobias, Adam M; Lee, Bernard T

    2013-09-01

    The patient-physician relationship has evolved from the paternalistic, physician-dominant model to the shared-decision-making and informed-consumerist model. The level of patient involvement in this decision-making process can potentially influence patient satisfaction and quality of life. In this study, patient-physician decision models are evaluated in patients undergoing postmastectomy breast reconstruction. All women who underwent breast reconstruction at an academic hospital from 1999-2007 were identified. Patients meeting inclusion criteria were mailed questionnaires at a minimum of 1 y postoperatively with questions about decision making, satisfaction, and quality of life. There were 707 women eligible for our study and 465 completed surveys (68% response rate). Patients were divided into one of three groups: paternalistic (n = 18), informed-consumerist (n = 307), shared (n = 140). There were differences in overall general satisfaction (P = 0.034), specifically comparing the informed group to the paternalistic group (66.7% versus 38.9%, P = 0.020) and the shared to the paternalistic group (69.3% versus 38.9%, P = 0.016). There were no differences in aesthetic satisfaction. There were differences found in the SF-12 physical component summary score across all groups (P = 0.033), and a difference was found between the informed and paternalistic groups (P mental component score (P = 0.42). Women undergoing breast reconstruction predominantly used the informed model of decision making. Patients who adopted a more active role, whether using an informed or shared approach, had higher general patient satisfaction and physical component summary scores compared with patients whose decision making was paternalistic. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Adaptive algebraic reconstruction technique

    International Nuclear Information System (INIS)

    Lu Wenkai; Yin Fangfang

    2004-01-01

    Algebraic reconstruction techniques (ART) are iterative procedures for reconstructing objects from their projections. It is proven that ART can be computationally efficient by carefully arranging the order in which the collected data are accessed during the reconstruction procedure and adaptively adjusting the relaxation parameters. In this paper, an adaptive algebraic reconstruction technique (AART), which adopts the same projection access scheme in multilevel scheme algebraic reconstruction technique (MLS-ART), is proposed. By introducing adaptive adjustment of the relaxation parameters during the reconstruction procedure, one-iteration AART can produce reconstructions with better quality, in comparison with one-iteration MLS-ART. Furthermore, AART outperforms MLS-ART with improved computational efficiency

  3. Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality--preliminary findings.

    Science.gov (United States)

    Miéville, Frédéric A; Gudinchet, François; Rizzo, Elena; Ou, Phalla; Brunelle, Francis; Bochud, François O; Verdun, Francis R

    2011-09-01

    Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI(vol) 4.8-7.9 mGy, DLP 37.1-178.9 mGy·cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. The best image quality for all clinical images was obtained with 20% and 40% ASIR (p ASIR above 50%, image quality significantly decreased (p ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone.

  4. Improving image quality of parallel phase-shifting digital holography

    International Nuclear Information System (INIS)

    Awatsuji, Yasuhiro; Tahara, Tatsuki; Kaneko, Atsushi; Koyama, Takamasa; Nishio, Kenzo; Ura, Shogo; Kubota, Toshihiro; Matoba, Osamu

    2008-01-01

    The authors propose parallel two-step phase-shifting digital holography to improve the image quality of parallel phase-shifting digital holography. The proposed technique can increase the effective number of pixels of hologram twice in comparison to the conventional parallel four-step technique. The increase of the number of pixels makes it possible to improve the image quality of the reconstructed image of the parallel phase-shifting digital holography. Numerical simulation and preliminary experiment of the proposed technique were conducted and the effectiveness of the technique was confirmed. The proposed technique is more practical than the conventional parallel phase-shifting digital holography, because the composition of the digital holographic system based on the proposed technique is simpler.

  5. Improved reconstruction for IDEAL spiral CSI

    DEFF Research Database (Denmark)

    Hansen, Rie Beck; Mariager, Christian; Laustsen, Christoffer

    2017-01-01

    In this study we demonstrate how reconstruction for IDEAL spiral CSI (spectroscopic imaging scheme developed for hyperpolarized dynamic metabolic MR imaging) can be improved by using regularization with a sparsity constraint. By exploiting sparsity of the spectral domain, IDEAL spiral CSI can...

  6. Improving head and neck CTA with hybrid and model-based iterative reconstruction techniques

    NARCIS (Netherlands)

    Niesten, J. M.; van der Schaaf, I. C.; Vos, P. C.; Willemink, MJ; Velthuis, B. K.

    2015-01-01

    AIM: To compare image quality of head and neck computed tomography angiography (CTA) reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR) and model-based iterative reconstruction (MIR) algorithms. MATERIALS AND METHODS: The raw data of 34 studies were

  7. Improved image quality for asymmetric double-focal cone-beam SPECT

    International Nuclear Information System (INIS)

    Cao, Z.J.; Tsui, B.M.W.

    1993-01-01

    To optimize both spatial resolution and detection efficiency in brain SPECT imaging using a rectangular camera, an asymmetric double-focal cone-beam collimator is proposed with the focal points located near the base plane of the patient's head. To fit the entire head into the field-of-view of the collimator with dimensions of 50cmx40cm and at a radius-of-rotation of 15 cm, the focal lengths of the collimator are 55 and 70 cm, respectively, in the transverse and axial directions. With this geometry, the artifacts in the reconstructed image produced by the Feldkamp algorithm are more severe compared to those in a symmetric cone-beam geometry, due to the larger vertex angle between the top of the head and the base plane. To improve the reconstructed image quality, a fully three-dimensional (3D) reconstruction algorithm developed previously for single-focal cone-beam SPECT was extended to the asymmetric double-focal cone-beam geometry. The algorithm involves nonstationary 2D filtering and a reprojection technique for estimation of the missing data caused by a single-orbit cone-beam geometry. The results from simulation studies with the 3D Defrise slab phantom demonstrated that the fully 3D algorithm provided a much improved image quality in terms of reduced slice-to-slice cross talks and shape elongation compared to that produced by the conventional Feldkamp algorithm

  8. Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)

    Energy Technology Data Exchange (ETDEWEB)

    Notohamiprodjo, S.; Deak, Z.; Meurer, F.; Maertz, F.; Mueck, F.G.; Geyer, L.L.; Wirth, S. [Ludwig-Maximilians University Hospital of Munich, Institute for Clinical Radiology, Munich (Germany)

    2015-01-15

    The purpose of this study was to compare cranial CT (CCT) image quality (IQ) of the MBIR algorithm with standard iterative reconstruction (ASiR). In this institutional review board (IRB)-approved study, raw data sets of 100 unenhanced CCT examinations (120 kV, 50-260 mAs, 20 mm collimation, 0.984 pitch) were reconstructed with both ASiR and MBIR. Signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated from attenuation values measured in caudate nucleus, frontal white matter, anterior ventricle horn, fourth ventricle, and pons. Two radiologists, who were blinded to the reconstruction algorithms, evaluated anonymized multiplanar reformations of 2.5 mm with respect to depiction of different parenchymal structures and impact of artefacts on IQ with a five-point scale (0: unacceptable, 1: less than average, 2: average, 3: above average, 4: excellent). MBIR decreased artefacts more effectively than ASiR (p < 0.01). The median depiction score for MBIR was 3, whereas the median value for ASiR was 2 (p < 0.01). SNR and CNR were significantly higher in MBIR than ASiR (p < 0.01). MBIR showed significant improvement of IQ parameters compared to ASiR. As CCT is an examination that is frequently required, the use of MBIR may allow for substantial reduction of radiation exposure caused by medical diagnostics. (orig.)

  9. Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)

    International Nuclear Information System (INIS)

    Notohamiprodjo, S.; Deak, Z.; Meurer, F.; Maertz, F.; Mueck, F.G.; Geyer, L.L.; Wirth, S.

    2015-01-01

    The purpose of this study was to compare cranial CT (CCT) image quality (IQ) of the MBIR algorithm with standard iterative reconstruction (ASiR). In this institutional review board (IRB)-approved study, raw data sets of 100 unenhanced CCT examinations (120 kV, 50-260 mAs, 20 mm collimation, 0.984 pitch) were reconstructed with both ASiR and MBIR. Signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated from attenuation values measured in caudate nucleus, frontal white matter, anterior ventricle horn, fourth ventricle, and pons. Two radiologists, who were blinded to the reconstruction algorithms, evaluated anonymized multiplanar reformations of 2.5 mm with respect to depiction of different parenchymal structures and impact of artefacts on IQ with a five-point scale (0: unacceptable, 1: less than average, 2: average, 3: above average, 4: excellent). MBIR decreased artefacts more effectively than ASiR (p < 0.01). The median depiction score for MBIR was 3, whereas the median value for ASiR was 2 (p < 0.01). SNR and CNR were significantly higher in MBIR than ASiR (p < 0.01). MBIR showed significant improvement of IQ parameters compared to ASiR. As CCT is an examination that is frequently required, the use of MBIR may allow for substantial reduction of radiation exposure caused by medical diagnostics. (orig.)

  10. Improvement of brain perfusion SPET using iterative reconstruction with scatter and non-uniform attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Kauppinen, T.; Vanninen, E.; Kuikka, J.T. [Kuopio Central Hospital (Finland). Dept. of Clinical Physiology; Koskinen, M.O. [Dept. of Clinical Physiology and Nuclear Medicine, Tampere Univ. Hospital, Tampere (Finland); Alenius, S. [Signal Processing Lab., Tampere Univ. of Technology, Tampere (Finland)

    2000-09-01

    Filtered back-projection (FBP) is generally used as the reconstruction method for single-photon emission tomography although it produces noisy images with apparent streak artefacts. It is possible to improve the image quality by using an algorithm with iterative correction steps. The iterative reconstruction technique also has an additional benefit in that computation of attenuation correction can be included in the process. A commonly used iterative method, maximum-likelihood expectation maximisation (ML-EM), can be accelerated using ordered subsets (OS-EM). We have applied to the OS-EM algorithm a Bayesian one-step late correction method utilising median root prior (MRP). Methodological comparison was performed by means of measurements obtained with a brain perfusion phantom and using patient data. The aim of this work was to quantitate the accuracy of iterative reconstruction with scatter and non-uniform attenuation corrections and post-filtering in SPET brain perfusion imaging. SPET imaging was performed using a triple-head gamma camera with fan-beam collimators. Transmission and emission scans were acquired simultaneously. The brain phantom used was a high-resolution three-dimensional anthropomorphic JB003 phantom. Patient studies were performed in ten chronic pain syndrome patients. The images were reconstructed using conventional FBP and iterative OS-EM and MRP techniques including scatter and nonuniform attenuation corrections. Iterative reconstructions were individually post-filtered. The quantitative results obtained with the brain perfusion phantom were compared with the known actual contrast ratios. The calculated difference from the true values was largest with the FBP method; iteratively reconstructed images proved closer to the reality. Similar findings were obtained in the patient studies. The plain OS-EM method improved the contrast whereas in the case of the MRP technique the improvement in contrast was not so evident with post-filtering. (orig.)

  11. Improvement of brain perfusion SPET using iterative reconstruction with scatter and non-uniform attenuation correction

    International Nuclear Information System (INIS)

    Kauppinen, T.; Vanninen, E.; Kuikka, J.T.; Alenius, S.

    2000-01-01

    Filtered back-projection (FBP) is generally used as the reconstruction method for single-photon emission tomography although it produces noisy images with apparent streak artefacts. It is possible to improve the image quality by using an algorithm with iterative correction steps. The iterative reconstruction technique also has an additional benefit in that computation of attenuation correction can be included in the process. A commonly used iterative method, maximum-likelihood expectation maximisation (ML-EM), can be accelerated using ordered subsets (OS-EM). We have applied to the OS-EM algorithm a Bayesian one-step late correction method utilising median root prior (MRP). Methodological comparison was performed by means of measurements obtained with a brain perfusion phantom and using patient data. The aim of this work was to quantitate the accuracy of iterative reconstruction with scatter and non-uniform attenuation corrections and post-filtering in SPET brain perfusion imaging. SPET imaging was performed using a triple-head gamma camera with fan-beam collimators. Transmission and emission scans were acquired simultaneously. The brain phantom used was a high-resolution three-dimensional anthropomorphic JB003 phantom. Patient studies were performed in ten chronic pain syndrome patients. The images were reconstructed using conventional FBP and iterative OS-EM and MRP techniques including scatter and nonuniform attenuation corrections. Iterative reconstructions were individually post-filtered. The quantitative results obtained with the brain perfusion phantom were compared with the known actual contrast ratios. The calculated difference from the true values was largest with the FBP method; iteratively reconstructed images proved closer to the reality. Similar findings were obtained in the patient studies. The plain OS-EM method improved the contrast whereas in the case of the MRP technique the improvement in contrast was not so evident with post-filtering. (orig.)

  12. Improving Weak Lensing Mass Map Reconstructions using Gaussian and Sparsity Priors: Application to DES SV

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey, N.; et al.

    2018-01-26

    Mapping the underlying density field, including non-visible dark matter, using weak gravitational lensing measurements is now a standard tool in cosmology. Due to its importance to the science results of current and upcoming surveys, the quality of the convergence reconstruction methods should be well understood. We compare three different mass map reconstruction methods: Kaiser-Squires (KS), Wiener filter, and GLIMPSE. KS is a direct inversion method, taking no account of survey masks or noise. The Wiener filter is well motivated for Gaussian density fields in a Bayesian framework. The GLIMPSE method uses sparsity, with the aim of reconstructing non-linearities in the density field. We compare these methods with a series of tests on the public Dark Energy Survey (DES) Science Verification (SV) data and on realistic DES simulations. The Wiener filter and GLIMPSE methods offer substantial improvement on the standard smoothed KS with a range of metrics. For both the Wiener filter and GLIMPSE convergence reconstructions we present a 12% improvement in Pearson correlation with the underlying truth from simulations. To compare the mapping methods' abilities to find mass peaks, we measure the difference between peak counts from simulated {\\Lambda}CDM shear catalogues and catalogues with no mass fluctuations. This is a standard data vector when inferring cosmology from peak statistics. The maximum signal-to-noise value of these peak statistic data vectors was increased by a factor of 3.5 for the Wiener filter and by a factor of 9 using GLIMPSE. With simulations we measure the reconstruction of the harmonic phases, showing that the concentration of the phase residuals is improved 17% by GLIMPSE and 18% by the Wiener filter. We show that the correlation between the reconstructions from data and the foreground redMaPPer clusters is increased 18% by the Wiener filter and 32% by GLIMPSE. [Abridged

  13. Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality - preliminary findings

    International Nuclear Information System (INIS)

    Mieville, Frederic A.; Gudinchet, Francois; Rizzo, Elena; Ou, Phalla; Brunelle, Francis; Bochud, Francois O.; Verdun, Francis R.

    2011-01-01

    Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI vol 4.8-7.9 mGy, DLP 37.1-178.9 mGy.cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. The best image quality for all clinical images was obtained with 20% and 40% ASIR (p < 0.001) whereas with ASIR above 50%, image quality significantly decreased (p < 0.001). With 100% ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone. (orig.)

  14. Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality - preliminary findings

    Energy Technology Data Exchange (ETDEWEB)

    Mieville, Frederic A. [University Hospital Center and University of Lausanne, Institute of Radiation Physics, Lausanne (Switzerland); University Hospital Center and University of Lausanne, Institute of Radiation Physics - Medical Radiology, Lausanne (Switzerland); Gudinchet, Francois; Rizzo, Elena [University Hospital Center and University of Lausanne, Department of Radiology, Lausanne (Switzerland); Ou, Phalla; Brunelle, Francis [Necker Children' s Hospital, Department of Radiology, Paris (France); Bochud, Francois O.; Verdun, Francis R. [University Hospital Center and University of Lausanne, Institute of Radiation Physics, Lausanne (Switzerland)

    2011-09-15

    Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI{sub vol} 4.8-7.9 mGy, DLP 37.1-178.9 mGy.cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. The best image quality for all clinical images was obtained with 20% and 40% ASIR (p < 0.001) whereas with ASIR above 50%, image quality significantly decreased (p < 0.001). With 100% ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone. (orig.)

  15. Approaches for improving image quality in magnetic induction tomography

    International Nuclear Information System (INIS)

    Maimaitijiang, Y; Roula, M A; Kahlert, J

    2010-01-01

    Magnetic induction tomography (MIT) is a contactless and non-invasive method for imaging the passive electrical properties of objects. Measuring the weak signal produced by eddy currents within biological soft tissues can be challenging in the presence of noise and the large signals resulting from the direct excitation–detection coil coupling. To detect haemorrhagic stroke in the brain, for instance, high measurement accuracy is required to enable images with enough contrast to differentiate between normal and haemorrhaged brain tissues. The reconstructed images are often very sensitive to inevitable measurement noise from the environment, system instabilities and patient-related artefacts such as movement and sweating. We propose methods for mitigating signal noise and improving image reconstruction. We evaluated and compared the use of a range wavelet transforms for signal denoising. Adaptive regularization methods including L-curve, generalized cross validation (GCV) and noise estimation were also compared. We evaluated all these described methods with measurements of in vitro tissues resembling a peripheral haemorrhagic cerebral stroke created by placing a bio-membrane package filled with 10 ml blood in a swine brain of 100 ml. We show that wavelet packet denoising combined with adaptive regularization can improve the quality of reconstructed images

  16. Improving Weak Lensing Mass Map Reconstructions using Gaussian and Sparsity Priors: Application to DES SV

    Science.gov (United States)

    Jeffrey, N.; Abdalla, F. B.; Lahav, O.; Lanusse, F.; Starck, J.-L.; Leonard, A.; Kirk, D.; Chang, C.; Baxter, E.; Kacprzak, T.; Seitz, S.; Vikram, V.; Whiteway, L.; Abbott, T. M. C.; Allam, S.; Avila, S.; Bertin, E.; Brooks, D.; Rosell, A. Carnero; Kind, M. Carrasco; Carretero, J.; Castander, F. J.; Crocce, M.; Cunha, C. E.; D'Andrea, C. B.; da Costa, L. N.; Davis, C.; De Vicente, J.; Desai, S.; Doel, P.; Eifler, T. F.; Evrard, A. E.; Flaugher, B.; Fosalba, P.; Frieman, J.; García-Bellido, J.; Gerdes, D. W.; Gruen, D.; Gruendl, R. A.; Gschwend, J.; Gutierrez, G.; Hartley, W. G.; Honscheid, K.; Hoyle, B.; James, D. J.; Jarvis, M.; Kuehn, K.; Lima, M.; Lin, H.; March, M.; Melchior, P.; Menanteau, F.; Miquel, R.; Plazas, A. A.; Reil, K.; Roodman, A.; Sanchez, E.; Scarpine, V.; Schubnell, M.; Sevilla-Noarbe, I.; Smith, M.; Soares-Santos, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Thomas, D.; Walker, A. R.

    2018-05-01

    Mapping the underlying density field, including non-visible dark matter, using weak gravitational lensing measurements is now a standard tool in cosmology. Due to its importance to the science results of current and upcoming surveys, the quality of the convergence reconstruction methods should be well understood. We compare three methods: Kaiser-Squires (KS), Wiener filter, and GLIMPSE. KS is a direct inversion, not accounting for survey masks or noise. The Wiener filter is well-motivated for Gaussian density fields in a Bayesian framework. GLIMPSE uses sparsity, aiming to reconstruct non-linearities in the density field. We compare these methods with several tests using public Dark Energy Survey (DES) Science Verification (SV) data and realistic DES simulations. The Wiener filter and GLIMPSE offer substantial improvements over smoothed KS with a range of metrics. Both the Wiener filter and GLIMPSE convergence reconstructions show a 12% improvement in Pearson correlation with the underlying truth from simulations. To compare the mapping methods' abilities to find mass peaks, we measure the difference between peak counts from simulated ΛCDM shear catalogues and catalogues with no mass fluctuations (a standard data vector when inferring cosmology from peak statistics); the maximum signal-to-noise of these peak statistics is increased by a factor of 3.5 for the Wiener filter and 9 for GLIMPSE. With simulations we measure the reconstruction of the harmonic phases; the phase residuals' concentration is improved 17% by GLIMPSE and 18% by the Wiener filter. The correlation between reconstructions from data and foreground redMaPPer clusters is increased 18% by the Wiener filter and 32% by GLIMPSE.

  17. Computed tomography imaging with the Adaptive Statistical Iterative Reconstruction (ASIR) algorithm: dependence of image quality on the blending level of reconstruction.

    Science.gov (United States)

    Barca, Patrizio; Giannelli, Marco; Fantacci, Maria Evelina; Caramella, Davide

    2018-06-01

    Computed tomography (CT) is a useful and widely employed imaging technique, which represents the largest source of population exposure to ionizing radiation in industrialized countries. Adaptive Statistical Iterative Reconstruction (ASIR) is an iterative reconstruction algorithm with the potential to allow reduction of radiation exposure while preserving diagnostic information. The aim of this phantom study was to assess the performance of ASIR, in terms of a number of image quality indices, when different reconstruction blending levels are employed. CT images of the Catphan-504 phantom were reconstructed using conventional filtered back-projection (FBP) and ASIR with reconstruction blending levels of 20, 40, 60, 80, and 100%. Noise, noise power spectrum (NPS), contrast-to-noise ratio (CNR) and modulation transfer function (MTF) were estimated for different scanning parameters and contrast objects. Noise decreased and CNR increased non-linearly up to 50 and 100%, respectively, with increasing blending level of reconstruction. Also, ASIR has proven to modify the NPS curve shape. The MTF of ASIR reconstructed images depended on tube load/contrast and decreased with increasing blending level of reconstruction. In particular, for low radiation exposure and low contrast acquisitions, ASIR showed lower performance than FBP, in terms of spatial resolution for all blending levels of reconstruction. CT image quality varies substantially with the blending level of reconstruction. ASIR has the potential to reduce noise whilst maintaining diagnostic information in low radiation exposure CT imaging. Given the opposite variation of CNR and spatial resolution with the blending level of reconstruction, it is recommended to use an optimal value of this parameter for each specific clinical application.

  18. Improvements to ATLAS Track Reconstruction for Run-II

    CERN Document Server

    Cairo, Valentina Maria; The ATLAS collaboration

    2015-01-01

    Run-II of the LHC will provide new challenges to track and vertex reconstruction with higher energies, denser jets and higher rates. In addition, the Insertable B-layer (IBL) is a fourth pixel layer, which has been inserted at the centre of ATLAS during the shutdown of the LHC. We will discuss improvements to track reconstruction developed during the two year shutdown of the LHC. These include novel techniques developed to improve the performance in the dense cores of jets, optimisation for the expected conditions, and a big software campaign which lead to more than a factor of three decrease in the CPU time needed to process each recorded event.

  19. Reconstruction of magnetic resonance imaging by three-dimensional dual-dictionary learning.

    Science.gov (United States)

    Song, Ying; Zhu, Zhen; Lu, Yang; Liu, Qiegen; Zhao, Jun

    2014-03-01

    To improve the magnetic resonance imaging (MRI) data acquisition speed while maintaining the reconstruction quality, a novel method is proposed for multislice MRI reconstruction from undersampled k-space data based on compressed-sensing theory using dictionary learning. There are two aspects to improve the reconstruction quality. One is that spatial correlation among slices is used by extending the atoms in dictionary learning from patches to blocks. The other is that the dictionary-learning scheme is used at two resolution levels; i.e., a low-resolution dictionary is used for sparse coding and a high-resolution dictionary is used for image updating. Numerical experiments are carried out on in vivo 3D MR images of brains and abdomens with a variety of undersampling schemes and ratios. The proposed method (dual-DLMRI) achieves better reconstruction quality than conventional reconstruction methods, with the peak signal-to-noise ratio being 7 dB higher. The advantages of the dual dictionaries are obvious compared with the single dictionary. Parameter variations ranging from 50% to 200% only bias the image quality within 15% in terms of the peak signal-to-noise ratio. Dual-DLMRI effectively uses the a priori information in the dual-dictionary scheme and provides dramatically improved reconstruction quality. Copyright © 2013 Wiley Periodicals, Inc.

  20. Health-related quality of life after maxillectomy: obturator rehabilitation compared with flap reconstruction.

    Science.gov (United States)

    Breeze, J; Rennie, A; Morrison, A; Dawson, D; Tipper, J; Rehman, K; Grew, N; Snee, D; Pigadas, N

    2016-10-01

    Health-related quality of life (QoL) reported by patients has the potential to improve care after ablative surgery of the midface, as existing treatment algorithms still generally revolve around outcomes assessed traditionally only by clinicians. Decisions in particular relate to reconstruction with a flap compared with rehabilitation with an obturator, the need for adjuvant treatment, and morbidity related to the size of the defect. We prospectively collected health-related QoL assessments for 39 consecutive patients treated by maxillectomy between 01 January 2010 and 31 December 2014 using the University of Washington Quality of Life Questionnaire, and who had a mean (SD) duration of follow-up of 14 (4). We made sub-group analyses using paired t tests and analysis of variance (ANOVA) to compare reconstruction with a flap with rehabilitation with obturators, size of the vertical defect, and whether adjuvant treatment with radiotherapy or chemoradiotherapy adversely affected it. Overall there was a significant decrease in health-related QoL after treatment compared with before (p<0.001), but there was no significant difference in the effects of any of the paired reconstructive and rehabilitation treatments on it. Obturators remain an important option for rehabilitation in selected patients in addition to reconstruction with a flap. We found that neither increasing the size of the vertical defect (in an attempt to ensure clear margins) nor the use of postoperative radiotherapy seemed to have any adverse effect on QoL. More patients are required before we can conclude that the potential survival benefits of such measures may outweigh any adverse effects. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Fast GPU-based Monte Carlo code for SPECT/CT reconstructions generates improved 177Lu images.

    Science.gov (United States)

    Rydén, T; Heydorn Lagerlöf, J; Hemmingsson, J; Marin, I; Svensson, J; Båth, M; Gjertsson, P; Bernhardt, P

    2018-01-04

    Full Monte Carlo (MC)-based SPECT reconstructions have a strong potential for correcting for image degrading factors, but the reconstruction times are long. The objective of this study was to develop a highly parallel Monte Carlo code for fast, ordered subset expectation maximum (OSEM) reconstructions of SPECT/CT images. The MC code was written in the Compute Unified Device Architecture language for a computer with four graphics processing units (GPUs) (GeForce GTX Titan X, Nvidia, USA). This enabled simulations of parallel photon emissions from the voxels matrix (128 3 or 256 3 ). Each computed tomography (CT) number was converted to attenuation coefficients for photo absorption, coherent scattering, and incoherent scattering. For photon scattering, the deflection angle was determined by the differential scattering cross sections. An angular response function was developed and used to model the accepted angles for photon interaction with the crystal, and a detector scattering kernel was used for modeling the photon scattering in the detector. Predefined energy and spatial resolution kernels for the crystal were used. The MC code was implemented in the OSEM reconstruction of clinical and phantom 177 Lu SPECT/CT images. The Jaszczak image quality phantom was used to evaluate the performance of the MC reconstruction in comparison with attenuated corrected (AC) OSEM reconstructions and attenuated corrected OSEM reconstructions with resolution recovery corrections (RRC). The performance of the MC code was 3200 million photons/s. The required number of photons emitted per voxel to obtain a sufficiently low noise level in the simulated image was 200 for a 128 3 voxel matrix. With this number of emitted photons/voxel, the MC-based OSEM reconstruction with ten subsets was performed within 20 s/iteration. The images converged after around six iterations. Therefore, the reconstruction time was around 3 min. The activity recovery for the spheres in the Jaszczak phantom was

  2. GPU accelerated CT reconstruction for clinical use: quality driven performance

    Science.gov (United States)

    Vaz, Michael S.; Sneyders, Yuri; McLin, Matthew; Ricker, Alan; Kimpe, Tom

    2007-03-01

    We present performance and quality analysis of GPU accelerated FDK filtered backprojection for cone beam computed tomography (CBCT) reconstruction. Our implementation of the FDK CT reconstruction algorithm does not compromise fidelity at any stage and yields a result that is within 1 HU of a reference C++ implementation. Our streaming implementation is able to perform reconstruction as the images are acquired; it addresses low latency as well as fast throughput, which are key considerations for a "real-time" design. Further, it is scaleable to multiple GPUs for increased performance. The implementation does not place any constraints on image acquisition; it works effectively for arbitrary angular coverage with arbitrary angular spacing. As such, this GPU accelerated CT reconstruction solution may easily be used with scanners that are already deployed. We are able to reconstruct a 512 x 512 x 340 volume from 625 projections, each sized 1024 x 768, in less than 50 seconds. The quoted 50 second timing encompasses the entire reconstruction using bilinear interpolation and includes filtering on the CPU, uploading the filtered projections to the GPU, and also downloading the reconstructed volume from GPU memory to system RAM.

  3. Impact of the adaptive statistical iterative reconstruction technique on image quality in ultra-low-dose CT

    International Nuclear Information System (INIS)

    Xu, Yan; He, Wen; Chen, Hui; Hu, Zhihai; Li, Juan; Zhang, Tingting

    2013-01-01

    Aim: To evaluate the relationship between different noise indices (NIs) and radiation dose and to compare the effect of different reconstruction algorithm applications for ultra-low-dose chest computed tomography (CT) on image quality improvement and the accuracy of volumetric measurement of ground-glass opacity (GGO) nodules using a phantom study. Materials and methods: A 11 cm thick transverse phantom section with a chest wall, mediastinum, and 14 artificial GGO nodules with known volumes (919.93 ± 64.05 mm 3 ) was constructed. The phantom was scanned on a Discovery CT 750HD scanner with five different NIs (NIs = 20, 30, 40, 50, and 60). All data were reconstructed with a 0.625 mm section thickness using the filtered back-projection (FBP), 50% adaptive statistical iterative reconstruction (ASiR), and Veo model-base iterative reconstruction algorithms. Image noise was measured in six regions of interest (ROIs). Nodule volumes were measured using a commercial volumetric software package. The image quality and the volume measurement errors were analysed. Results: Image noise increased dramatically from 30.7 HU at NI 20 to 122.4 HU at NI 60, with FBP reconstruction. Conversely, Veo reconstruction effectively controlled the noise increase, with an increase from 9.97 HU at NI 20 to only 15.1 HU at NI 60. Image noise at NI 60 with Veo was even lower (50.8%) than that at NI 20 with FBP. The contrast-to-noise ratio (CNR) of Veo at NI 40 was similar to that of FBP at NI 20. All artificial GGO nodules were successfully identified and measured with an average relative volume measurement error with Veo at NI 60 of 4.24%, comparable to a value of 10.41% with FBP at NI 20. At NI 60, the radiation dose was only one-tenth that at NI 20. Conclusion: The Veo reconstruction algorithms very effectively reduced image noise compared with the conventional FBP reconstructions. Using ultra-low-dose CT scanning and Veo reconstruction, GGOs can be detected and quantified with an acceptable

  4. WE-AB-207A-08: BEST IN PHYSICS (IMAGING): Advanced Scatter Correction and Iterative Reconstruction for Improved Cone-Beam CT Imaging On the TrueBeam Radiotherapy Machine

    Energy Technology Data Exchange (ETDEWEB)

    Wang, A; Paysan, P; Brehm, M; Maslowski, A; Lehmann, M; Messmer, P; Munro, P; Yoon, S; Star-Lack, J; Seghers, D [Varian Medical Systems, Palo Alto, CA (United States)

    2016-06-15

    Purpose: To improve CBCT image quality for image-guided radiotherapy by applying advanced reconstruction algorithms to overcome scatter, noise, and artifact limitations Methods: CBCT is used extensively for patient setup in radiotherapy. However, image quality generally falls short of diagnostic CT, limiting soft-tissue based positioning and potential applications such as adaptive radiotherapy. The conventional TrueBeam CBCT reconstructor uses a basic scatter correction and FDK reconstruction, resulting in residual scatter artifacts, suboptimal image noise characteristics, and other artifacts like cone-beam artifacts. We have developed an advanced scatter correction that uses a finite-element solver (AcurosCTS) to model the behavior of photons as they pass (and scatter) through the object. Furthermore, iterative reconstruction is applied to the scatter-corrected projections, enforcing data consistency with statistical weighting and applying an edge-preserving image regularizer to reduce image noise. The combined algorithms have been implemented on a GPU. CBCT projections from clinically operating TrueBeam systems have been used to compare image quality between the conventional and improved reconstruction methods. Planning CT images of the same patients have also been compared. Results: The advanced scatter correction removes shading and inhomogeneity artifacts, reducing the scatter artifact from 99.5 HU to 13.7 HU in a typical pelvis case. Iterative reconstruction provides further benefit by reducing image noise and eliminating streak artifacts, thereby improving soft-tissue visualization. In a clinical head and pelvis CBCT, the noise was reduced by 43% and 48%, respectively, with no change in spatial resolution (assessed visually). Additional benefits include reduction of cone-beam artifacts and reduction of metal artifacts due to intrinsic downweighting of corrupted rays. Conclusion: The combination of an advanced scatter correction with iterative reconstruction

  5. Improvements in image quality with pseudo-parallel imaging in the phase-scrambling fourier transform technique

    International Nuclear Information System (INIS)

    Ito, Satoshi; Kawawa, Yasuhiro; Yamada, Yoshifumi

    2010-01-01

    The signal obtained in the phase-scrambling Fourier transform (PSFT) imaging technique can be transformed to the signal described by the Fresnel transform of the objects, in which the amplitude of the PSFT presents some kind of blurred image of the objects. Therefore, the signal can be considered to exist in the object domain as well as the Fourier domain of the object. This notable feature makes it possible to assign weights to the reconstructed images by applying a weighting function to the PSFT signal after data acquisition, and as a result, pseudo-parallel image reconstruction using these aliased image data with different weights on the images is feasible. In this study, the improvements in image quality with such pseudo-parallel imaging were examined and demonstrated. The weighting function of the PSFT signal that provides a given weight on the image is estimated using the obtained image data and is iteratively updated after sensitivity encoding (SENSE)-based image reconstruction. Simulation studies showed that reconstruction errors were dramatically reduced and that the spatial resolution was also improved in almost all image spaces. The proposed method was applied to signals synthesized from MR image data with phase variations to verify its effectiveness. It was found that the image quality was improved and that images almost entirely free of aliasing artifacts could be obtained. (author)

  6. Improvements to ATLAS track reconstruction for Run II

    Energy Technology Data Exchange (ETDEWEB)

    Cairo, Valentina Maria Martina, E-mail: valentina.maria.cairo@cern.ch [University of Calabria, Arcavacata di Rende (Italy); CERN, Meyrin (Switzerland)

    2016-07-11

    Run II of the LHC will provide new challenges to track and vertex reconstruction with higher energies, denser jets and higher rates. A major change to the Inner Detector layout during the shutdown period has been the installation of the Insertable B-Layer, a fourth pixel layer located at a radius of 33 mm. This contribution discusses improvements to track reconstruction developed during the two year shutdown of the LHC. These include novel techniques developed to improve the performance in the dense cores of jets, optimisation for the expected conditions, and a big software campaign which lead to more than a factor of three decrease in the CPU time needed to process each recorded event.

  7. Quantitative research versus quality assurance, quality improvement, total quality management, and continuous quality improvement.

    Science.gov (United States)

    Vogelsang, J

    1999-04-01

    The purpose of this report is to provide a review of the scientific method used in the quantitative research studies for consumers, evaluators, and applied nurse researchers. The fundamental characteristics of the problem-solving/ performance-improvement processes of quality assurance, quality improvement, total quality management, and continuous quality improvement are described. Research is compared with these processes, and is followed by a discussion about the publication of quantitative research findings.

  8. Recent advances in iterative reconstruction for clinical SPECT/PET and CT.

    Science.gov (United States)

    Hutton, Brian F

    2011-08-01

    Statistical iterative reconstruction is now widely used in clinical practice and has contributed to significant improvement in image quality in recent years. Although primarily used for reconstruction in emission tomography (both single photon emission computed tomography (SPECT) and positron emission tomography (PET)) there is increasing interest in also applying similar algorithms to x-ray computed tomography (CT). There is increasing complexity in the factors that are included in the reconstruction, a demonstration of the versatility of the approach. Research continues with exploration of methods for further improving reconstruction quality with effective correction for various sources of artefact.

  9. Implementation and Analysis of a Lean Six Sigma Program in Microsurgery to Improve Operative Throughput in Perforator Flap Breast Reconstruction.

    Science.gov (United States)

    Hultman, Charles Scott; Kim, Sendia; Lee, Clara N; Wu, Cindy; Dodge, Becky; Hultman, Chloe Elizabeth; Roach, S Tanner; Halvorson, Eric G

    2016-06-01

    Perforator flaps have become a preferred method of breast reconstruction but can consume considerable resources. We examined the impact of a Six Sigma program on microsurgical breast reconstruction at an academic medical center. Using methods developed by Motorola and General Electric, we applied critical pathway planning, workflow analysis, lean manufacturing, continuous quality improvement, and defect reduction to microsurgical breast reconstruction. Primary goals were to decrease preoperative-to-cut time and total operative time, through reduced variability and improved efficiency. Secondary goals were to reduce length of stay, complications, and reoperation. The project was divided into 3 phases: (1) Pre-Six Sigma (24 months), (2) Six Sigma (10 months), (3) and Post-Six Sigma (24 months). These periods (baseline, intervention, control) were compared by Student t test and χ analysis. Over a 5-year period, 112 patients underwent 168 perforator flaps for breast reconstructions, by experienced microsurgeons. Total operative time decreased from 714 to 607 minutes (P Six Sigma program in microsurgical breast reconstruction was associated with better operational and financial outcomes. These incremental gains were maintained over the course of the study, suggesting that these benefits were due, in part, to process improvements. However, continued reductions in total operative time and length of stay, well after the intervention period, support the possibility that "learning curve" phenomenon may have contributed to the improvement in these outcomes.

  10. Task-based image quality evaluation of iterative reconstruction methods for low dose CT using computer simulations

    Science.gov (United States)

    Xu, Jingyan; Fuld, Matthew K.; Fung, George S. K.; Tsui, Benjamin M. W.

    2015-04-01

    Iterative reconstruction (IR) methods for x-ray CT is a promising approach to improve image quality or reduce radiation dose to patients. The goal of this work was to use task based image quality measures and the channelized Hotelling observer (CHO) to evaluate both analytic and IR methods for clinical x-ray CT applications. We performed realistic computer simulations at five radiation dose levels, from a clinical reference low dose D0 to 25% D0. A fixed size and contrast lesion was inserted at different locations into the liver of the XCAT phantom to simulate a weak signal. The simulated data were reconstructed on a commercial CT scanner (SOMATOM Definition Flash; Siemens, Forchheim, Germany) using the vendor-provided analytic (WFBP) and IR (SAFIRE) methods. The reconstructed images were analyzed by CHOs with both rotationally symmetric (RS) and rotationally oriented (RO) channels, and with different numbers of lesion locations (5, 10, and 20) in a signal known exactly (SKE), background known exactly but variable (BKEV) detection task. The area under the receiver operating characteristic curve (AUC) was used as a summary measure to compare the IR and analytic methods; the AUC was also used as the equal performance criterion to derive the potential dose reduction factor of IR. In general, there was a good agreement in the relative AUC values of different reconstruction methods using CHOs with RS and RO channels, although the CHO with RO channels achieved higher AUCs than RS channels. The improvement of IR over analytic methods depends on the dose level. The reference dose level D0 was based on a clinical low dose protocol, lower than the standard dose due to the use of IR methods. At 75% D0, the performance improvement was statistically significant (p < 0.05). The potential dose reduction factor also depended on the detection task. For the SKE/BKEV task involving 10 lesion locations, a dose reduction of at least 25% from D0 was achieved.

  11. A combination-weighted Feldkamp-based reconstruction algorithm for cone-beam CT

    International Nuclear Information System (INIS)

    Mori, Shinichiro; Endo, Masahiro; Komatsu, Shuhei; Kandatsu, Susumu; Yashiro, Tomoyasu; Baba, Masayuki

    2006-01-01

    The combination-weighted Feldkamp algorithm (CW-FDK) was developed and tested in a phantom in order to reduce cone-beam artefacts and enhance cranio-caudal reconstruction coverage in an attempt to improve image quality when utilizing cone-beam computed tomography (CBCT). Using a 256-slice cone-beam CT (256CBCT), image quality (CT-number uniformity and geometrical accuracy) was quantitatively evaluated in phantom and clinical studies, and the results were compared to those obtained with the original Feldkamp algorithm. A clinical study was done in lung cancer patients under breath holding and free breathing. Image quality for the original Feldkamp algorithm is degraded at the edge of the scan region due to the missing volume, commensurate with the cranio-caudal distance between the reconstruction and central planes. The CW-FDK extended the reconstruction coverage to equal the scan coverage and improved reconstruction accuracy, unaffected by the cranio-caudal distance. The extended reconstruction coverage with good image quality provided by the CW-FDK will be clinically investigated for improving diagnostic and radiotherapy applications. In addition, this algorithm can also be adapted for use in relatively wide cone-angle CBCT such as with a flat-panel detector CBCT

  12. Knowledge-based iterative model reconstruction technique in computed tomography of lumbar spine lowers radiation dose and improves tissue differentiation for patients with lower back pain

    International Nuclear Information System (INIS)

    Yang, Cheng Hui; Wu, Tung-Hsin; Lin, Chung-Jung; Chiou, Yi-You; Chen, Ying-Chou; Sheu, Ming-Huei; Guo, Wan-Yuo; Chiu, Chen Fen

    2016-01-01

    Highlights: • Knowledge-based IMR improves tissue differentiation in CT of L-spine better than hybrid IR (iDose 4 ). • Higher strength IMR improves image qualities of the IVD and IVF in spinal stenosis. • IMR provides diagnostic lower dose CT of L-spine. - Abstract: Purpose: To evaluate the image quality and diagnostic confidence of reduced-dose computed tomography (CT) of the lumbar spine (L-spine) reconstructed with knowledge-based iterative model reconstruction (IMR). Materials and methods: Prospectively, group A consisted of 55 patients imaged with standard acquisition reconstructed with filtered back-projection. Group B consisted of 58 patients imaged with half tube current, reconstructed with hybrid iterative reconstruction (iDose 4 ) in Group B1 and knowledge-based IMR in Group B2. Signal-to-noise ratio (SNR) of different regions, the contrast-to-noise ratio between the intervetebral disc (IVD) and dural sac (D-D CNR), and subjective image quality of different regions were compared. Higher strength IMR was also compared in spinal stenosis cases. Results: The SNR of the psoas muscle and D-D CNR were significantly higher in the IMR group. Except for the facet joint, subjective image quality of other regions including IVD, intervertebral foramen (IVF), dural sac, peridural fat, ligmentum flavum, and overall diagnostic acceptability were best for the IMR group. Diagnostic confidence of narrowing IVF and IVD was good (kappa = 0.58–0.85). Higher strength IMR delineated IVD better in spinal stenosis cases. Conclusion: Lower dose CT of L-spine reconstructed with IMR demonstrates better tissue differentiation than iDose 4 and standard dose CT with FBP.

  13. Knowledge-based iterative model reconstruction technique in computed tomography of lumbar spine lowers radiation dose and improves tissue differentiation for patients with lower back pain

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Cheng Hui [Department of Medical Imaging, Pojen General Hopsital, Taipei, Taiwan (China); School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Wu, Tung-Hsin [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan (China); Lin, Chung-Jung, E-mail: bcjlin@me.com [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan (China); Chiou, Yi-You; Chen, Ying-Chou; Sheu, Ming-Huei; Guo, Wan-Yuo; Chiu, Chen Fen [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan (China)

    2016-10-15

    Highlights: • Knowledge-based IMR improves tissue differentiation in CT of L-spine better than hybrid IR (iDose{sup 4}). • Higher strength IMR improves image qualities of the IVD and IVF in spinal stenosis. • IMR provides diagnostic lower dose CT of L-spine. - Abstract: Purpose: To evaluate the image quality and diagnostic confidence of reduced-dose computed tomography (CT) of the lumbar spine (L-spine) reconstructed with knowledge-based iterative model reconstruction (IMR). Materials and methods: Prospectively, group A consisted of 55 patients imaged with standard acquisition reconstructed with filtered back-projection. Group B consisted of 58 patients imaged with half tube current, reconstructed with hybrid iterative reconstruction (iDose{sup 4}) in Group B1 and knowledge-based IMR in Group B2. Signal-to-noise ratio (SNR) of different regions, the contrast-to-noise ratio between the intervetebral disc (IVD) and dural sac (D-D CNR), and subjective image quality of different regions were compared. Higher strength IMR was also compared in spinal stenosis cases. Results: The SNR of the psoas muscle and D-D CNR were significantly higher in the IMR group. Except for the facet joint, subjective image quality of other regions including IVD, intervertebral foramen (IVF), dural sac, peridural fat, ligmentum flavum, and overall diagnostic acceptability were best for the IMR group. Diagnostic confidence of narrowing IVF and IVD was good (kappa = 0.58–0.85). Higher strength IMR delineated IVD better in spinal stenosis cases. Conclusion: Lower dose CT of L-spine reconstructed with IMR demonstrates better tissue differentiation than iDose{sup 4} and standard dose CT with FBP.

  14. An analytical statistical approach to the 3D reconstruction problem

    Energy Technology Data Exchange (ETDEWEB)

    Cierniak, Robert [Czestochowa Univ. of Technology (Poland). Inst. of Computer Engineering

    2011-07-01

    The presented here approach is concerned with the reconstruction problem for 3D spiral X-ray tomography. The reconstruction problem is formulated taking into considerations the statistical properties of signals obtained in X-ray CT. Additinally, image processing performed in our approach is involved in analytical methodology. This conception significantly improves quality of the obtained after reconstruction images and decreases the complexity of the reconstruction problem in comparison with other approaches. Computer simulations proved that schematically described here reconstruction algorithm outperforms conventional analytical methods in obtained image quality. (orig.)

  15. MO-C-18A-01: Advances in Model-Based 3D Image Reconstruction

    International Nuclear Information System (INIS)

    Chen, G; Pan, X; Stayman, J; Samei, E

    2014-01-01

    Recent years have seen the emergence of CT image reconstruction techniques that exploit physical models of the imaging system, photon statistics, and even the patient to achieve improved 3D image quality and/or reduction of radiation dose. With numerous advantages in comparison to conventional 3D filtered backprojection, such techniques bring a variety of challenges as well, including: a demanding computational load associated with sophisticated forward models and iterative optimization methods; nonlinearity and nonstationarity in image quality characteristics; a complex dependency on multiple free parameters; and the need to understand how best to incorporate prior information (including patient-specific prior images) within the reconstruction process. The advantages, however, are even greater – for example: improved image quality; reduced dose; robustness to noise and artifacts; task-specific reconstruction protocols; suitability to novel CT imaging platforms and noncircular orbits; and incorporation of known characteristics of the imager and patient that are conventionally discarded. This symposium features experts in 3D image reconstruction, image quality assessment, and the translation of such methods to emerging clinical applications. Dr. Chen will address novel methods for the incorporation of prior information in 3D and 4D CT reconstruction techniques. Dr. Pan will show recent advances in optimization-based reconstruction that enable potential reduction of dose and sampling requirements. Dr. Stayman will describe a “task-based imaging” approach that leverages models of the imaging system and patient in combination with a specification of the imaging task to optimize both the acquisition and reconstruction process. Dr. Samei will describe the development of methods for image quality assessment in such nonlinear reconstruction techniques and the use of these methods to characterize and optimize image quality and dose in a spectrum of clinical

  16. GPU-accelerated Kernel Regression Reconstruction for Freehand 3D Ultrasound Imaging.

    Science.gov (United States)

    Wen, Tiexiang; Li, Ling; Zhu, Qingsong; Qin, Wenjian; Gu, Jia; Yang, Feng; Xie, Yaoqin

    2017-07-01

    Volume reconstruction method plays an important role in improving reconstructed volumetric image quality for freehand three-dimensional (3D) ultrasound imaging. By utilizing the capability of programmable graphics processing unit (GPU), we can achieve a real-time incremental volume reconstruction at a speed of 25-50 frames per second (fps). After incremental reconstruction and visualization, hole-filling is performed on GPU to fill remaining empty voxels. However, traditional pixel nearest neighbor-based hole-filling fails to reconstruct volume with high image quality. On the contrary, the kernel regression provides an accurate volume reconstruction method for 3D ultrasound imaging but with the cost of heavy computational complexity. In this paper, a GPU-based fast kernel regression method is proposed for high-quality volume after the incremental reconstruction of freehand ultrasound. The experimental results show that improved image quality for speckle reduction and details preservation can be obtained with the parameter setting of kernel window size of [Formula: see text] and kernel bandwidth of 1.0. The computational performance of the proposed GPU-based method can be over 200 times faster than that on central processing unit (CPU), and the volume with size of 50 million voxels in our experiment can be reconstructed within 10 seconds.

  17. Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children.

    Science.gov (United States)

    Kim, Hyun Gi; Lee, Ho-Joon; Lee, Seung-Koo; Kim, Hyun Ji; Kim, Myung-Joon

    2017-09-01

    To investigate the quality of images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V), using pediatric head CT protocols. A phantom was scanned at decreasing 20% mA intervals using our standard pediatric head CT protocols. Each study was then reconstructed at 10% ASIR-V intervals. After the phantom study, we reduced mA by 10% in the protocol for ASIR-V and by 30% in the protocol for 3- to 15-year-old patients and applied 40% ASIR-V. Increasing the percentage of ASIR-V resulted in lower noise and higher contrast-to-noise ratio (CNR) and preserved spatial resolution in the phantom study. Compared to a conventional-protocol, reduced-dose protocol with ASIR-V achieved 12.8% to 34.0% of dose reduction and showed images of lower noise (9.22 vs. 10.73, P = 0.043) and higher CNR in different levels (centrum semiovale, 2.14 vs. 1.52, P = 0.003; basal ganglia, 1.46 vs. 1.07, P = 0.001; and cerebellum, 2.18 vs. 1.33, P ASIR-V. Use of ASIR-V allowed a 12.8% to 34.0% dose reduction in each age group with potential to improve image quality. • It is possible to reduce radiation dose and improve image quality with ASIR-V. • We improved noise and CNR and decreased radiation dose. • Sharpness improved with ASIR-V. • Total radiation dose was decreased by 12.8% to 34.0%.

  18. Improving image quality in Electrical Impedance Tomography (EIT using Projection Error Propagation-based Regularization (PEPR technique: A simulation study

    Directory of Open Access Journals (Sweden)

    Tushar Kanti Bera

    2011-03-01

    Full Text Available A Projection Error Propagation-based Regularization (PEPR method is proposed and the reconstructed image quality is improved in Electrical Impedance Tomography (EIT. A projection error is produced due to the misfit of the calculated and measured data in the reconstruction process. The variation of the projection error is integrated with response matrix in each iterations and the reconstruction is carried out in EIDORS. The PEPR method is studied with the simulated boundary data for different inhomogeneity geometries. Simulated results demonstrate that the PEPR technique improves image reconstruction precision in EIDORS and hence it can be successfully implemented to increase the reconstruction accuracy in EIT.>doi:10.5617/jeb.158 J Electr Bioimp, vol. 2, pp. 2-12, 2011

  19. Task-based statistical image reconstruction for high-quality cone-beam CT

    Science.gov (United States)

    Dang, Hao; Webster Stayman, J.; Xu, Jennifer; Zbijewski, Wojciech; Sisniega, Alejandro; Mow, Michael; Wang, Xiaohui; Foos, David H.; Aygun, Nafi; Koliatsos, Vassilis E.; Siewerdsen, Jeffrey H.

    2017-11-01

    Task-based analysis of medical imaging performance underlies many ongoing efforts in the development of new imaging systems. In statistical image reconstruction, regularization is often formulated in terms to encourage smoothness and/or sharpness (e.g. a linear, quadratic, or Huber penalty) but without explicit formulation of the task. We propose an alternative regularization approach in which a spatially varying penalty is determined that maximizes task-based imaging performance at every location in a 3D image. We apply the method to model-based image reconstruction (MBIR—viz., penalized weighted least-squares, PWLS) in cone-beam CT (CBCT) of the head, focusing on the task of detecting a small, low-contrast intracranial hemorrhage (ICH), and we test the performance of the algorithm in the context of a recently developed CBCT prototype for point-of-care imaging of brain injury. Theoretical predictions of local spatial resolution and noise are computed via an optimization by which regularization (specifically, the quadratic penalty strength) is allowed to vary throughout the image to maximize local task-based detectability index ({{d}\\prime} ). Simulation studies and test-bench experiments were performed using an anthropomorphic head phantom. Three PWLS implementations were tested: conventional (constant) penalty; a certainty-based penalty derived to enforce constant point-spread function, PSF; and the task-based penalty derived to maximize local detectability at each location. Conventional (constant) regularization exhibited a fairly strong degree of spatial variation in {{d}\\prime} , and the certainty-based method achieved uniform PSF, but each exhibited a reduction in detectability compared to the task-based method, which improved detectability up to ~15%. The improvement was strongest in areas of high attenuation (skull base), where the conventional and certainty-based methods tended to over-smooth the data. The task-driven reconstruction method presents a

  20. Including RNA secondary structures improves accuracy and robustness in reconstruction of phylogenetic trees.

    Science.gov (United States)

    Keller, Alexander; Förster, Frank; Müller, Tobias; Dandekar, Thomas; Schultz, Jörg; Wolf, Matthias

    2010-01-15

    In several studies, secondary structures of ribosomal genes have been used to improve the quality of phylogenetic reconstructions. An extensive evaluation of the benefits of secondary structure, however, is lacking. This is the first study to counter this deficiency. We inspected the accuracy and robustness of phylogenetics with individual secondary structures by simulation experiments for artificial tree topologies with up to 18 taxa and for divergency levels in the range of typical phylogenetic studies. We chose the internal transcribed spacer 2 of the ribosomal cistron as an exemplary marker region. Simulation integrated the coevolution process of sequences with secondary structures. Additionally, the phylogenetic power of marker size duplication was investigated and compared with sequence and sequence-structure reconstruction methods. The results clearly show that accuracy and robustness of Neighbor Joining trees are largely improved by structural information in contrast to sequence only data, whereas a doubled marker size only accounts for robustness. Individual secondary structures of ribosomal RNA sequences provide a valuable gain of information content that is useful for phylogenetics. Thus, the usage of ITS2 sequence together with secondary structure for taxonomic inferences is recommended. Other reconstruction methods as maximum likelihood, bayesian inference or maximum parsimony may equally profit from secondary structure inclusion. This article was reviewed by Shamil Sunyaev, Andrea Tanzer (nominated by Frank Eisenhaber) and Eugene V. Koonin. Reviewed by Shamil Sunyaev, Andrea Tanzer (nominated by Frank Eisenhaber) and Eugene V. Koonin. For the full reviews, please go to the Reviewers' comments section.

  1. Multicenter evaluation of quality of life and patient satisfaction after breast reconstruction, a long-term retrospective study.

    Science.gov (United States)

    Ménez, T; Michot, A; Tamburino, S; Weigert, R; Pinsolle, V

    2018-04-01

    Breast reconstruction techniques are multiple and they should be chosen in order to improve women's satisfaction and well-being, thus obtaining a personalized treatment. This report's major purpose was to study, through the Breast-Q questionnaire, how the functional and aesthetic outcomes, as well as the complications, of the main autologous breast reconstruction techniques, can affect patients quality of life and well-being at long-term. The secondary purpose was to analyse, thus to identify, the independent factors characterizing the different reconstructive techniques, which may affect patients' satisfaction. Women who underwent autologous breast reconstruction through deep inferior epigastric artery perforator or Latissimus dorsi muscle flap from May 2006 to May 2013 were included. The assessment was based on the Breast-Q reconstruction questionnaire. All times of post-mastectomy reconstruction were concerned: immediate, delayed, after previous procedure failure or conversion to another reconstructive technique due to the patient's dissatisfaction. A total of 98 patients were included. Concerning patients satisfaction, the breast-Q score is highest in patients who underwent immediate breast reconstruction, while scores after delayed breast reconstruction, previous surgery failure or conversion to another technique are generally equivalent. Higher scores have been observed in patients who underwent reconstruction through autologous Latissimus dorsi compared to Latissimus dorsi with prosthetic implant reconstruction. The authors identified factors of higher patients' satisfaction, like absence of major complication and advanced patient's age, in order to personalize the surgical planning according to the patient's priorities. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Mieville, Frederic A.; Bochud, Francois O.; Verdun, Francis R. [Lausanne University Hospital, Institute of Radiation Physics, Lausanne (Switzerland); Berteloot, Laureline; Brunelle, Francis [Necker Children' s Hospital of Paris and University of Paris Descartes, Department of Pediatric Radiology, Paris (France); Grandjean, Albane; Ayestaran, Paul [General Electric Medical Systems Europe, Paris (France); Gudinchet, Francois; Schmidt, Sabine [Lausanne University Hospital, Department of Radiology, Lausanne (Switzerland)

    2013-03-15

    The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEO trademark is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. To evaluate the potential of VEO trademark on diagnostic image quality and dose reduction in pediatric chest CT examinations. Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDI{sub vol} 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection. (orig.)

  3. EnzDP: improved enzyme annotation for metabolic network reconstruction based on domain composition profiles.

    Science.gov (United States)

    Nguyen, Nam-Ninh; Srihari, Sriganesh; Leong, Hon Wai; Chong, Ket-Fah

    2015-10-01

    Determining the entire complement of enzymes and their enzymatic functions is a fundamental step for reconstructing the metabolic network of cells. High quality enzyme annotation helps in enhancing metabolic networks reconstructed from the genome, especially by reducing gaps and increasing the enzyme coverage. Currently, structure-based and network-based approaches can only cover a limited number of enzyme families, and the accuracy of homology-based approaches can be further improved. Bottom-up homology-based approach improves the coverage by rebuilding Hidden Markov Model (HMM) profiles for all known enzymes. However, its clustering procedure relies firmly on BLAST similarity score, ignoring protein domains/patterns, and is sensitive to changes in cut-off thresholds. Here, we use functional domain architecture to score the association between domain families and enzyme families (Domain-Enzyme Association Scoring, DEAS). The DEAS score is used to calculate the similarity between proteins, which is then used in clustering procedure, instead of using sequence similarity score. We improve the enzyme annotation protocol using a stringent classification procedure, and by choosing optimal threshold settings and checking for active sites. Our analysis shows that our stringent protocol EnzDP can cover up to 90% of enzyme families available in Swiss-Prot. It achieves a high accuracy of 94.5% based on five-fold cross-validation. EnzDP outperforms existing methods across several testing scenarios. Thus, EnzDP serves as a reliable automated tool for enzyme annotation and metabolic network reconstruction. Available at: www.comp.nus.edu.sg/~nguyennn/EnzDP .

  4. Collaborative quality improvement.

    Science.gov (United States)

    Luckenbaugh, Amy N; Miller, David C; Ghani, Khurshid R

    2017-07-01

    Quality improvement collaboratives were developed in many medical and surgical disciplines with the goal of measuring and improving the quality of care provided to patients. The aim of this review is to provide an overview of surgical quality improvement collaboratives, and in particular those aimed at improving urological care. Quality improvement collaboratives collect high-quality data using standardized methodologies, and use the data to provide feedback to physicians and practices, and then implement processes to improve patient outcomes. The largest regional collaborative in urology is the Michigan Urological Surgery Improvement Collaborative (MUSIC). Recent efforts by this group have been focused at understanding variation in care, improving patient selection for treatment, reducing treatment morbidity and measuring and optimizing technical skill. The American Urological Association has also recently launched a national quality registry (AQUA), with an initial focus on prostate cancer care. By understanding factors that result in exemplary performance, quality improvement collaboratives are able to develop best practices around areas of care with high variation that have the potential to improve outcomes and reduce costs. These developments have been made possible by the unique model offered by the collaborative structure with the goal of improving patient care at a population level.

  5. A biomechanical modeling-guided simultaneous motion estimation and image reconstruction technique (SMEIR-Bio) for 4D-CBCT reconstruction

    Science.gov (United States)

    Huang, Xiaokun; Zhang, You; Wang, Jing

    2018-02-01

    Reconstructing four-dimensional cone-beam computed tomography (4D-CBCT) images directly from respiratory phase-sorted traditional 3D-CBCT projections can capture target motion trajectory, reduce motion artifacts, and reduce imaging dose and time. However, the limited numbers of projections in each phase after phase-sorting decreases CBCT image quality under traditional reconstruction techniques. To address this problem, we developed a simultaneous motion estimation and image reconstruction (SMEIR) algorithm, an iterative method that can reconstruct higher quality 4D-CBCT images from limited projections using an inter-phase intensity-driven motion model. However, the accuracy of the intensity-driven motion model is limited in regions with fine details whose quality is degraded due to insufficient projection number, which consequently degrades the reconstructed image quality in corresponding regions. In this study, we developed a new 4D-CBCT reconstruction algorithm by introducing biomechanical modeling into SMEIR (SMEIR-Bio) to boost the accuracy of the motion model in regions with small fine structures. The biomechanical modeling uses tetrahedral meshes to model organs of interest and solves internal organ motion using tissue elasticity parameters and mesh boundary conditions. This physics-driven approach enhances the accuracy of solved motion in the organ’s fine structures regions. This study used 11 lung patient cases to evaluate the performance of SMEIR-Bio, making both qualitative and quantitative comparisons between SMEIR-Bio, SMEIR, and the algebraic reconstruction technique with total variation regularization (ART-TV). The reconstruction results suggest that SMEIR-Bio improves the motion model’s accuracy in regions containing small fine details, which consequently enhances the accuracy and quality of the reconstructed 4D-CBCT images.

  6. Optimization of PET image quality by means of 3D data acquisition and iterative image reconstruction

    International Nuclear Information System (INIS)

    Doll, J.; Zaers, J.; Trojan, H.; Bellemann, M.E.; Adam, L.E.; Haberkorn, U.; Brix, G.

    1998-01-01

    The experiments were performed at the latest-generation whole-body PET system ECAT EXACT HR + . For 2D data acquisition, a collimator of thin tungsten septa was positioned in the field-of-view. Prior to image reconstruction, the measured 3D data were sorted into 2D sinograms by using the Fourier rebinning (FORE) algorithm developed by M. Defrise. The standard filtered backprojection (FBP) method and an optimized ML/EM algorithm with overrelaxation for accelerated convergence were employed for image reconstruction. The spatial resolution of both methods as well as the convergence and noise properties of the ML/EM algorithm were studied in phantom measurements. Furthermore, patient data were acquired in the 2D mode as well as in the 3D mode and reconstructed with both techniques. At the same spatial resolution, the ML/EM-reconstructed images showed fewer and less prominent artefacts than the FBP-reconstructed images. The resulting improved detail conspicuously was achieved for the data acquired in the 2D mode as well as in the 3D mode. The best image quality was obtained by iterative 2D reconstruction of 3D data sets which were previously rebinned into 2D sinograms with help of the FORE algorithm. The phantom measurements revealed that 50 iteration steps with the otpimized ML/EM algorithm were sufficient to keep the relative quantitation error below 5%. (orig./MG) [de

  7. An Advanced Pre-Processing Pipeline to Improve Automated Photogrammetric Reconstructions of Architectural Scenes

    Directory of Open Access Journals (Sweden)

    Marco Gaiani

    2016-02-01

    Full Text Available Automated image-based 3D reconstruction methods are more and more flooding our 3D modeling applications. Fully automated solutions give the impression that from a sample of randomly acquired images we can derive quite impressive visual 3D models. Although the level of automation is reaching very high standards, image quality is a fundamental pre-requisite to produce successful and photo-realistic 3D products, in particular when dealing with large datasets of images. This article presents an efficient pipeline based on color enhancement, image denoising, color-to-gray conversion and image content enrichment. The pipeline stems from an analysis of various state-of-the-art algorithms and aims to adjust the most promising methods, giving solutions to typical failure causes. The assessment evaluation proves how an effective image pre-processing, which considers the entire image dataset, can improve the automated orientation procedure and dense 3D point cloud reconstruction, even in the case of poor texture scenarios.

  8. Effects of silicone expanders and implants on echocardiographic image quality after breast reconstruction.

    Science.gov (United States)

    Pignatti, Marco; Mantovani, Francesca; Bertelli, Luca; Barbieri, Andrea; Pacchioni, Lucrezia; Loschi, Pietro; De Santis, Giorgio

    2013-08-01

    Use of silicone expanders and implants is the most common breast reconstruction technique after mastectomy. Postmastectomy patients often need echocardiographic monitoring of potential cardiotoxicity induced by cancer chemotherapy. The impairment of the echocardiographic acoustic window caused by silicone implants for breast augmentation has been reported. This study investigates whether the echocardiographic image quality was impaired in women reconstructed with silicone expanders and implants. The records of 44 consecutive women who underwent echocardiographic follow-up after breast reconstruction with expanders and implants at the authors' institution from January of 2000 to August of 2012 were reviewed. The population was divided into a study group (left or bilateral breast expanders/implants, n=30) and a control group (right breast expanders/implants, n=14). The impact of breast expanders/implants on echocardiographic image quality was tested (analysis of covariance model). Patients with a breast expander/implant (left or bilateral and right breast expanders/implants) were included. The mean volume of the breast devices was 353.2±125.5 cc. The quality of the echocardiographic images was good or sufficient in the control group; in the study group, it was judged as adequate in only 50 percent of cases (15 patients) and inadequate in the remaining 15 patients (pimplants in postmastectomy left breast reconstruction considerably reduce the image quality of echocardiography. This may have important clinical implications, given the need for periodic echocardiographic surveillance before and during chemotherapy. Therapeutic, III.

  9. Adaptive statistical iterative reconstruction improves image quality without affecting perfusion CT quantitation in primary colorectal cancer

    Directory of Open Access Journals (Sweden)

    D. Prezzi

    Full Text Available Objectives: To determine the effect of Adaptive Statistical Iterative Reconstruction (ASIR on perfusion CT (pCT parameter quantitation and image quality in primary colorectal cancer. Methods: Prospective observational study. Following institutional review board approval and informed consent, 32 patients with colorectal adenocarcinoma underwent pCT (100 kV, 150 mA, 120 s acquisition, axial mode. Tumour regional blood flow (BF, blood volume (BV, mean transit time (MTT and permeability surface area product (PS were determined using identical regions-of-interests for ASIR percentages of 0%, 20%, 40%, 60%, 80% and 100%. Image noise, contrast-to-noise ratio (CNR and pCT parameters were assessed across ASIR percentages. Coefficients of variation (CV, repeated measures analysis of variance (rANOVA and Spearman’ rank order correlation were performed with statistical significance at 5%. Results: With increasing ASIR percentages, image noise decreased by 33% while CNR increased by 61%; peak tumour CNR was greater than 1.5 with 60% ASIR and above. Mean BF, BV, MTT and PS differed by less than 1.8%, 2.9%, 2.5% and 2.6% across ASIR percentages. CV were 4.9%, 4.2%, 3.3% and 7.9%; rANOVA P values: 0.85, 0.62, 0.02 and 0.81 respectively. Conclusions: ASIR improves image noise and CNR without altering pCT parameters substantially. Keywords: Perfusion imaging, Multidetector computed tomography, Colorectal neoplasms, Computer-assisted image processing, Radiation dosage

  10. Evaluating climate field reconstruction techniques using improved emulations of real-world conditions

    Science.gov (United States)

    Wang, J.; Emile-Geay, J.; Guillot, D.; Smerdon, J. E.; Rajaratnam, B.

    2014-01-01

    Pseudoproxy experiments (PPEs) have become an important framework for evaluating paleoclimate reconstruction methods. Most existing PPE studies assume constant proxy availability through time and uniform proxy quality across the pseudoproxy network. Real multiproxy networks are, however, marked by pronounced disparities in proxy quality, and a steep decline in proxy availability back in time, either of which may have large effects on reconstruction skill. A suite of PPEs constructed from a millennium-length general circulation model (GCM) simulation is thus designed to mimic these various real-world characteristics. The new pseudoproxy network is used to evaluate four climate field reconstruction (CFR) techniques: truncated total least squares embedded within the regularized EM (expectation-maximization) algorithm (RegEM-TTLS), the Mann et al. (2009) implementation of RegEM-TTLS (M09), canonical correlation analysis (CCA), and Gaussian graphical models embedded within RegEM (GraphEM). Each method's risk properties are also assessed via a 100-member noise ensemble. Contrary to expectation, it is found that reconstruction skill does not vary monotonically with proxy availability, but also is a function of the type and amplitude of climate variability (forced events vs. internal variability). The use of realistic spatiotemporal pseudoproxy characteristics also exposes large inter-method differences. Despite the comparable fidelity in reconstructing the global mean temperature, spatial skill varies considerably between CFR techniques. Both GraphEM and CCA efficiently exploit teleconnections, and produce consistent reconstructions across the ensemble. RegEM-TTLS and M09 appear advantageous for reconstructions on highly noisy data, but are subject to larger stochastic variations across different realizations of pseudoproxy noise. Results collectively highlight the importance of designing realistic pseudoproxy networks and implementing multiple noise realizations of PPEs

  11. Contrast improvement of continuous wave diffuse optical tomography reconstruction by hybrid approach using least square and genetic algorithm

    Science.gov (United States)

    Patra, Rusha; Dutta, Pranab K.

    2015-07-01

    Reconstruction of the absorption coefficient of tissue with good contrast is of key importance in functional diffuse optical imaging. A hybrid approach using model-based iterative image reconstruction and a genetic algorithm is proposed to enhance the contrast of the reconstructed image. The proposed method yields an observed contrast of 98.4%, mean square error of 0.638×10-3, and object centroid error of (0.001 to 0.22) mm. Experimental validation of the proposed method has also been provided with tissue-like phantoms which shows a significant improvement in image quality and thus establishes the potential of the method for functional diffuse optical tomography reconstruction with continuous wave setup. A case study of finger joint imaging is illustrated as well to show the prospect of the proposed method in clinical diagnosis. The method can also be applied to the concentration measurement of a region of interest in a turbid medium.

  12. Cross-sectional analysis of Quality-of-Life of patients undergoing reconstructive surgery for tongue cancer

    International Nuclear Information System (INIS)

    Yoshimoto, Seiichi; Kimata, Yasuhiro; Kurita, Tomoyuki

    2009-01-01

    Organs with important functions for daily life are concentrated in the head and neck area, and maintaining post-treatment Quality-of-Life (QOL) is also important when treating cancers of the head and neck, in addition to improving survival rate. Free flap reconstruction techniques are expected to contribute to maintaining post-treatment QOL, but these techniques have not been adequately evaluated in Japan. We performed a cross-sectional analysis of QOL, using the Japanese version of the UWQOL (version 4) from the University of Washington in the United States, with 202 patients from 10 institutions who had undergone reconstructive surgery for tongue cancer. In addition to the survey form, we collected clinical information (age, sex, time since surgery, flap donor site, whether radiotherapy was administered, and other factors), and analyzed whether differences in postoperative QOL were seen depending on each of these factors and the hospital at which the surgery was performed. Although a relationship was found between QOL following reconstructive surgery for tongue cancer and the extent of resection, age and whether radiotherapy was administered, fairly good QOL was maintained overall. (author)

  13. Application of project design peer review to improve quality assurance

    International Nuclear Information System (INIS)

    McClure, F.E.

    1989-01-01

    DOE ORDER 5481.1B Safety Analysis and Review Systems and DOE ORDER 6430.1A General Design Criteria require that the design of facilities shall incorporate the necessary Quality Assurance review requirements to assure that the established program quality assurance objectives are met in the design criteria and the construction documents. The use of Project Design Peer Review to satisfy these requirements is presented. The University of California manages the Lawrence Berkeley Laboratory, the Lawrence Livermore National Laboratory, and the Los Alamos National Scientific Laboratory. The 1988 University Seismic Safety Policy requires the use of independent Project Design Peer Review in its capital improvement and seismic reconstruction program

  14. Effect of masking phase-only holograms on the quality of reconstructed images.

    Science.gov (United States)

    Deng, Yuanbo; Chu, Daping

    2016-04-20

    A phase-only hologram modulates the phase of the incident light and diffracts it efficiently with low energy loss because of the minimum absorption. Much research attention has been focused on how to generate phase-only holograms, and little work has been done to understand the effect and limitation of their partial implementation, possibly due to physical defects and constraints, in particular as in the practical situations where a phase-only hologram is confined or needs to be sliced or tiled. The present study simulates the effect of masking phase-only holograms on the quality of reconstructed images in three different scenarios with different filling factors, filling positions, and illumination intensity profiles. Quantitative analysis confirms that the width of the image point spread function becomes wider and the image quality decreases, as expected, when the filling factor decreases, and the image quality remains the same for different filling positions as well. The width of the image point spread function as derived from different filling factors shows a consistent behavior to that as measured directly from the reconstructed image, especially as the filling factor becomes small. Finally, mask profiles of different shapes and intensity distributions are shown to have more complicated effects on the image point spread function, which in turn affects the quality and textures of the reconstructed image.

  15. Teaching quality improvement.

    Science.gov (United States)

    Murray, Marry Ellen; Douglas, Stephen; Girdley, Diana; Jarzemsky, Paula

    2010-08-01

    Practicing nurses are required to engage in quality improvement work as a part of their clinical practice, but few undergraduate nursing education programs offer course work and applied experience in this area. This article presents a description of class content and teaching strategies, assignments, and evaluation strategies designed to achieve the Quality and Safety Education in Nursing competencies related to quality improvement and interdisciplinary teams. Students demonstrate their application of the quality improvement process by designing and implementing a small-scale quality improvement project that they report in storyboard format on a virtual conference Web site.

  16. Including RNA secondary structures improves accuracy and robustness in reconstruction of phylogenetic trees

    Directory of Open Access Journals (Sweden)

    Dandekar Thomas

    2010-01-01

    Full Text Available Abstract Background In several studies, secondary structures of ribosomal genes have been used to improve the quality of phylogenetic reconstructions. An extensive evaluation of the benefits of secondary structure, however, is lacking. Results This is the first study to counter this deficiency. We inspected the accuracy and robustness of phylogenetics with individual secondary structures by simulation experiments for artificial tree topologies with up to 18 taxa and for divergency levels in the range of typical phylogenetic studies. We chose the internal transcribed spacer 2 of the ribosomal cistron as an exemplary marker region. Simulation integrated the coevolution process of sequences with secondary structures. Additionally, the phylogenetic power of marker size duplication was investigated and compared with sequence and sequence-structure reconstruction methods. The results clearly show that accuracy and robustness of Neighbor Joining trees are largely improved by structural information in contrast to sequence only data, whereas a doubled marker size only accounts for robustness. Conclusions Individual secondary structures of ribosomal RNA sequences provide a valuable gain of information content that is useful for phylogenetics. Thus, the usage of ITS2 sequence together with secondary structure for taxonomic inferences is recommended. Other reconstruction methods as maximum likelihood, bayesian inference or maximum parsimony may equally profit from secondary structure inclusion. Reviewers This article was reviewed by Shamil Sunyaev, Andrea Tanzer (nominated by Frank Eisenhaber and Eugene V. Koonin. Open peer review Reviewed by Shamil Sunyaev, Andrea Tanzer (nominated by Frank Eisenhaber and Eugene V. Koonin. For the full reviews, please go to the Reviewers' comments section.

  17. Qualitative and quantitative improvements of PET reconstruction on GPU architecture

    International Nuclear Information System (INIS)

    Autret, Awen

    2016-01-01

    In positron emission tomography, reconstructed images suffer from a high noise level and a low resolution. Iterative reconstruction processes require an estimation of the system response (scanner and patient) and the quality of the images depends on the accuracy of this estimate. Accurate and fast to compute models already exists for the attenuation, scattering, random coincidences and dead times. Thus, this thesis focuses on modeling the system components associated with the detector response and the positron range. A new multi-GPU parallelization of the reconstruction based on a cutting of the volume is also proposed to speed up the reconstruction exploiting the computing power of such architectures. The proposed detector response model is based on a multi-ray approach that includes all the detector effects as the geometry and the scattering in the crystals. An evaluation study based on data obtained through Mote Carlo simulation (MCS) showed this model provides reconstructed images with a better contrast to noise ratio and resolution compared with those of the methods from the state of the art. The proposed positron range model is based on a simplified MCS, integrated into the forward projector during the reconstruction. A GPU implementation of this method allows running MCS three order of magnitude faster than the same simulation on GATE, while providing similar results. An evaluation study shows this model integrated in the reconstruction gives images with better contrast recovery and resolution while avoiding artifacts. (author)

  18. Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Gonca; Courtier, Jesse L.; Phelps, Andrew; Marcovici, Peter A.; MacKenzie, John D. [UCSF Benioff Children' s Hospital, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States)

    2014-07-15

    Computed tomography (CT) is extremely important in characterizing blood vessel anatomy and vascular lesions in children. Recent advances in CT reconstruction technology hold promise for improved image quality and also reductions in radiation dose. This report evaluates potential improvements in image quality for the depiction of small pediatric vessels with model-based iterative reconstruction (Veo trademark), a technique developed to improve image quality and reduce noise. To evaluate Veo trademark as an improved method when compared to adaptive statistical iterative reconstruction (ASIR trademark) for the depiction of small vessels on pediatric CT. Seventeen patients (mean age: 3.4 years, range: 2 days to 10.0 years; 6 girls, 11 boys) underwent contrast-enhanced CT examinations of the chest and abdomen in this HIPAA compliant and institutional review board approved study. Raw data were reconstructed into separate image datasets using Veo trademark and ASIR trademark algorithms (GE Medical Systems, Milwaukee, WI). Four blinded radiologists subjectively evaluated image quality. The pulmonary, hepatic, splenic and renal arteries were evaluated for the length and number of branches depicted. Datasets were compared with parametric and non-parametric statistical tests. Readers stated a preference for Veo trademark over ASIR trademark images when subjectively evaluating image quality criteria for vessel definition, image noise and resolution of small anatomical structures. The mean image noise in the aorta and fat was significantly less for Veo trademark vs. ASIR trademark reconstructed images. Quantitative measurements of mean vessel lengths and number of branches vessels delineated were significantly different for Veo trademark and ASIR trademark images. Veo trademark consistently showed more of the vessel anatomy: longer vessel length and more branching vessels. When compared to the more established adaptive statistical iterative reconstruction algorithm, model

  19. Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction

    International Nuclear Information System (INIS)

    Koc, Gonca; Courtier, Jesse L.; Phelps, Andrew; Marcovici, Peter A.; MacKenzie, John D.

    2014-01-01

    Computed tomography (CT) is extremely important in characterizing blood vessel anatomy and vascular lesions in children. Recent advances in CT reconstruction technology hold promise for improved image quality and also reductions in radiation dose. This report evaluates potential improvements in image quality for the depiction of small pediatric vessels with model-based iterative reconstruction (Veo trademark), a technique developed to improve image quality and reduce noise. To evaluate Veo trademark as an improved method when compared to adaptive statistical iterative reconstruction (ASIR trademark) for the depiction of small vessels on pediatric CT. Seventeen patients (mean age: 3.4 years, range: 2 days to 10.0 years; 6 girls, 11 boys) underwent contrast-enhanced CT examinations of the chest and abdomen in this HIPAA compliant and institutional review board approved study. Raw data were reconstructed into separate image datasets using Veo trademark and ASIR trademark algorithms (GE Medical Systems, Milwaukee, WI). Four blinded radiologists subjectively evaluated image quality. The pulmonary, hepatic, splenic and renal arteries were evaluated for the length and number of branches depicted. Datasets were compared with parametric and non-parametric statistical tests. Readers stated a preference for Veo trademark over ASIR trademark images when subjectively evaluating image quality criteria for vessel definition, image noise and resolution of small anatomical structures. The mean image noise in the aorta and fat was significantly less for Veo trademark vs. ASIR trademark reconstructed images. Quantitative measurements of mean vessel lengths and number of branches vessels delineated were significantly different for Veo trademark and ASIR trademark images. Veo trademark consistently showed more of the vessel anatomy: longer vessel length and more branching vessels. When compared to the more established adaptive statistical iterative reconstruction algorithm, model

  20. New designs in the reconstruction of coke-sorting systems

    Energy Technology Data Exchange (ETDEWEB)

    A.S. Larin; V.V. Demenko; V.L. Voitanik [Giprokoks, the State Institute for the Design of Coke-Industry Enterprises, Kharkov (Ukraine)

    2009-07-15

    In recent Giprokoks designs for the reconstruction of coke-sorting systems, high-productivity vibrational-inertial screens have been employed. This permits single-stage screening and reduction in capital and especially operating expenditures, without loss of coke quality. In two-stage screening, >80 mm coke (for foundry needs) is additionally separated, with significant improvement in quality of the metallurgical coke (25-80 mm). New designs for the reconstruction of coke-sorting systems employ mechanical treatment of the coke outside the furnace, which offers new scope for stabilization of coke quality and permits considerable improvement in mechanical strength and granulometric composition of the coke by mechanical crushing.

  1. Improved immediate breast reconstruction as a result of oncoplastic multidisciplinary meeting

    Directory of Open Access Journals (Sweden)

    El Gammal MM

    2017-04-01

    Full Text Available Mohsen M El Gammal,1 Maria Lim,1 Rajan Uppal,2 Richard Sainsbury1 1Department of Breast Surgery, Parapet Breast Centre, Frimley Health Foundation Trust, Windsor, 2Department of Plastic and Reconstructive Surgery, Wexham and Heatherwood Hospital, Frimley Health Foundation Trust, Slough, UK Introduction: The National Institute for Health and Clinical Excellence guidelines recommend that breast reconstruction should be available to all women undergoing mastectomy and discussed at the initial surgical consultation (2002, and updated 2009. The National Mastectomy and Breast Reconstruction Audit (2009 showed that 21% of mastectomy patients underwent immediate breast reconstruction (IBR and 11% had delayed breast reconstruction (DBR. Breast reconstruction has been shown to have a positive effect on quality of life postmastectomy. This retrospective study investigated the impact of the introduction of a dedicated oncoplastic multidisciplinary meeting (OP MDM on our unit’s breast reconstruction rate.Patients and methods: A retrospective analysis of 229 women who underwent mastectomy, of whom 81 (35% underwent breast reconstruction between April 2014 and March 2016. Data were analyzed before and after introduction of OP MDM in April 2015. Data on patient age, type of surgery (mastectomy only, mastectomy and reconstruction, timing of reconstruction (IBR, DBR, and type of reconstruction (implant, autologous were collected.Results: Between April 2015 and March 2016, following establishment of OP multidisciplinary team in April 2015, of the 120 patients who had mastectomy, 50 (42% underwent breast reconstruction with 78% (39/50 choosing IBR (56% implant reconstruction and 22% autologous. Compared to the period between April 2014 and March 2015 preceding the OP MDM, of 109 patients who underwent mastectomy, only 31 (28% had breast reconstruction with 64% (20/31 choosing IBR (45% implant reconstruction and 19% autologous. The rate of DBR was lower, 22% (11

  2. Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography

    International Nuclear Information System (INIS)

    Sato, Jiro; Akahane, Masaaki; Inano, Sachiko; Terasaki, Mariko; Akai, Hiroyuki; Katsura, Masaki; Matsuda, Izuru; Kunimatsu, Akira; Ohtomo, Kuni

    2012-01-01

    The purpose of this study was to assess the effects of dose and adaptive statistical iterative reconstruction (ASIR) on image quality of pulmonary computed tomography (CT). Inflated and fixed porcine lungs were scanned with a 64-slice CT system at 10, 20, 40 and 400 mAs. Using automatic exposure control, 40 mAs was chosen as standard dose. Scan data were reconstructed with filtered back projection (FBP) and ASIR. Image pairs were obtained by factorial combination of images at a selected level. Using a 21-point scale, three experienced radiologists independently rated differences in quality between adjacently displayed paired images for image noise, image sharpness and conspicuity of tiny nodules. A subjective quality score (SQS) for each image was computed based on Anderson's functional measurement theory. The standard deviation was recorded as a quantitative noise measurement. At all doses examined, SQSs improved with ASIR for all evaluation items. No significant differences were noted between the SQSs for 40%-ASIR images obtained at 20 mAs and those for FBP images at 40 mAs. Compared to the FBP algorithm, ASIR for lung CT can enable an approximately 50% dose reduction from the standard dose while preserving visualization of small structures. (author)

  3. CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT

    International Nuclear Information System (INIS)

    Gervaise, Alban; Osemont, Benoit; Lecocq, Sophie; Blum, Alain; Noel, Alain; Micard, Emilien; Felblinger, Jacques

    2012-01-01

    To evaluate the impact of Adaptive Iterative Dose Reduction (AIDR) on image quality and radiation dose in phantom and patient studies. A phantom was examined in volumetric mode on a 320-detector CT at different tube currents from 25 to 550 mAs. CT images were reconstructed with AIDR and with Filtered Back Projection (FBP) reconstruction algorithm. Image noise, Contrast-to-Noise Ratio (CNR), Signal-to-Noise Ratio (SNR) and spatial resolution were compared between FBP and AIDR images. AIDR was then tested on 15 CT examinations of the lumbar spine in a prospective study. Again, FBP and AIDR images were compared. Image noise and SNR were analysed using a Wilcoxon signed-rank test. In the phantom, spatial resolution assessment showed no significant difference between FBP and AIDR reconstructions. Image noise was lower with AIDR than with FBP images with a mean reduction of 40%. CNR and SNR were also improved with AIDR. In patients, quantitative and subjective evaluation showed that image noise was significantly lower with AIDR than with FBP. SNR was also greater with AIDR than with FBP. Compared to traditional FBP reconstruction techniques, AIDR significantly improves image quality and has the potential to decrease radiation dose. (orig.)

  4. Developing a theoretical framework to illustrate associations among patient satisfaction, body image and quality of life for women undergoing breast reconstruction.

    Science.gov (United States)

    Fingeret, Michelle Cororve; Nipomnick, Summer W; Crosby, Melissa A; Reece, Gregory P

    2013-10-01

    Within the field of breast reconstruction there is increasing focus on patient-reported outcomes related to satisfaction, body image, and quality of life. These outcomes are deemed highly relevant because the primary goal of breast reconstruction is to recreate the appearance of a breast (or breasts) that is satisfying to the patient. Prominent researchers have suggested the need to develop improved standards for outcome evaluation which can ultimately benefit patients as well as physicians. The purpose of this article is to summarize key findings in the area of patient-reported outcomes for breast reconstruction and introduce a theoretical framework for advancing research in this field. We conducted an extensive literature review of outcome studies for breast reconstruction focusing on patient-reported results. We developed a theoretical framework illustrating core patient-reported outcomes related to breast reconstruction and factors associated with these outcomes. Our theoretical model highlights domains and distinguishing features of patient satisfaction, body image, and quality of life outcomes for women undergoing breast reconstruction. This model further identifies a broad range of variables (e.g., historical/premorbid influences, disease and treatment-related factors) that have been found to influence patient-reported outcomes and need to be taken into consideration when designing future research in this area. Additional attention is given to examining the relationship between patient reported outcomes and outside evaluation of breast reconstruction. Our proposed theoretical framework suggests key opportunities to expand research in this area with the goal of optimizing body image adjustment, satisfaction, and psychosocial outcomes for the individual patient. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Abdominal wall reconstruction for incisional hernia optimizes truncal function and quality of life

    DEFF Research Database (Denmark)

    Jensen, Kristian K.; Munim, Kanzah; Kjaer, Michael

    2017-01-01

    Objective: The aim of the study was to examine abdominal wall function in patients undergoing abdominal wall reconstruction (AWR) for incisional hernia. Background: The literature on abdominal wall function in patients with incisional hernia is sparse. It has been suggested that AWR leads...... to improvement in function, but it is unknown whether this is specific to the abdominal wall or due to an improvement in overall physical fitness. Methods: We performed a prospective case-control study of 18 consecutive patients with large incisional hernia undergoing AWR with linea alba restoration. Truncal...... flexion and extension strength, hand grip strength, leg extension power, and quality of life (SF-36 and Carolinas Comfort Scale) were assessed preoperatively and 1 year postoperatively. Patients were compared with a control group of patients with an intact abdominal wall undergoing colorectal resection (n...

  6. Robust framework for PET image reconstruction incorporating system and measurement uncertainties.

    Directory of Open Access Journals (Sweden)

    Huafeng Liu

    Full Text Available In Positron Emission Tomography (PET, an optimal estimate of the radioactivity concentration is obtained from the measured emission data under certain criteria. So far, all the well-known statistical reconstruction algorithms require exactly known system probability matrix a priori, and the quality of such system model largely determines the quality of the reconstructed images. In this paper, we propose an algorithm for PET image reconstruction for the real world case where the PET system model is subject to uncertainties. The method counts PET reconstruction as a regularization problem and the image estimation is achieved by means of an uncertainty weighted least squares framework. The performance of our work is evaluated with the Shepp-Logan simulated and real phantom data, which demonstrates significant improvements in image quality over the least squares reconstruction efforts.

  7. Impact of cleft lip and/or palate in children on family quality of life before and after reconstructive surgery.

    Science.gov (United States)

    Macho, P; Bohac, M; Fedeles, J; Fekiacova, D; Fedeles, J

    2017-01-01

    The aim of the study was to evaluate the impact of cleft lip/palate children together with consequent treatment on quality of family life using standardized questionnaire. Different to previous studies the evaluation of quality of family life by questionnaire was realized twice in the same group of families (before the reconstructive surgery and several months after palatoplasty). The study was conducted in 40 families divided in two groups: 20 families with children with cleft lip (CL), 20 families with children with cleft lip and palate (CLP). The questionnaire of the Impact on Family Scale was used for evaluation of the influence of orofacial clefts on parent´s quality of life. Evaluations were made at the second month of child´s life and at one year of child´s life with reciprocally comparison. The higher impact of children with CLP on quality of family life was noted at 2 months and 1 year of child's age as compared to the impact of children with CL. The reduction of impact on quality of life after surgical correction was observed in families of children with CL at one year of child's age. This decrease of influence on family quality of life was due to significantly lower impact in strain and economic dimensions in families with CL children after operation. However, in the group of families with CLP children no significant changes in the impact on family quality of life were noted when compared to the values before and shortly after the reconstructive surgery. This study showed that orofacial clefts in children influence markedly the quality of their family life. The higher impact of children with CLP on quality of family life as compared to children with CL was noted and this impact in CLP group was not influenced shortly after reconstructive surgery. It is suggested that appropriate medical care in Cleft Centre with special psychological support may lead to improvement in quality of life for families with cleft lip and palate children (Tab. 2, Fig. 2, Ref

  8. Coronary CT angiography: Comparison of a novel iterative reconstruction with filtered back projection for reconstruction of low-dose CT—Initial experience

    International Nuclear Information System (INIS)

    Takx, Richard A.P.; Schoepf, U. Joseph; Moscariello, Antonio; Das, Marco; Rowe, Garrett; Schoenberg, Stefan O.; Fink, Christian; Henzler, Thomas

    2013-01-01

    Objective: To prospectively compare subjective and objective image quality in 20% tube current coronary CT angiography (cCTA) datasets between an iterative reconstruction algorithm (SAFIRE) and traditional filtered back projection (FBP). Materials and methods: Twenty patients underwent a prospectively ECG-triggered dual-step cCTA protocol using 2nd generation dual-source CT (DSCT). CT raw data was reconstructed using standard FBP at full-dose (Group 1 a) and 80% tube current reduced low-dose (Group 1 b). The low-dose raw data was additionally reconstructed using iterative raw data reconstruction (Group 2 ). Attenuation and image noise were measured in three regions of interest and signal-to-noise-ratio (SNR) as well as contrast-to-noise-ratio (CNR) was calculated. Subjective diagnostic image quality was evaluated using a 4-point Likert scale. Results: Mean image noise of group 2 was lowered by 22% on average when compared to group 1 b (p 2 compared to group 1 b (p 2 (1.88 ± 0.63) was also rated significantly higher when compared to group 1 b (1.58 ± 0.63, p = 0.004). Conclusions: Image quality of 80% tube current reduced iteratively reconstructed cCTA raw data is significantly improved when compared to standard FBP and consequently may improve the diagnostic accuracy of cCTA

  9. Quality of image and exposure dose according to kVp, mA and lterative reconstruction in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Sang Young [Dept. of Radiology, Inha University Hospital, Incheon (Korea, Republic of); Park, Jae Yoon [Dept. of Radiology, Incheon Christian Hospital, Incheon (Korea, Republic of); Lee, Yong Ki [Dept. of Radiological Technology, DongNam Health University, Suwon (Korea, Republic of); Kim, Jeon Hun [Dept. of Radiatioin Oncology, Konyang University Hospital, Daejeon (Korea, Republic of); Choi, Jae Ho [Dept. of Radiological Technology, Ansan University, Ansan (Korea, Republic of)

    2017-09-15

    The purpose of this study is to investigate the image quality and exposure dose according to kVp and mAs in CT and to confirm improvement in image quality according to None IR and IR(Iterative Reconstruction) levels. Measurement results of image quality using Image J, HU(Hounsfield units) and BN(Background Noise) are decreased, while SNR(Signal to Noise Ratio) and CTDIvol(CT dose index volume) are increased as the kVp increases and there was no change of BHU(Background Hounsfield units). BN was reduced due to increased kVp, while SNR and CTDIvol were increased. Also, the higher IR stage, the lower BN, SI(Signal Intensity) and HU while SNR was improved by about 10∼60%. Based on this, when applying IR for clinical applications, it is necessary to finely adjust kVp and mA with a phased approach.

  10. Comparison of the image qualities of filtered back-projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction for CT venography at 80 kVp

    International Nuclear Information System (INIS)

    Kim, Jin Hyeok; Choo, Ki Seok; Moon, Tae Yong; Lee, Jun Woo; Jeon, Ung Bae; Kim, Tae Un; Hwang, Jae Yeon; Yun, Myeong-Ja; Jeong, Dong Wook; Lim, Soo Jin

    2016-01-01

    To evaluate the subjective and objective qualities of computed tomography (CT) venography images at 80 kVp using model-based iterative reconstruction (MBIR) and to compare these with those of filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) using the same CT data sets. Forty-four patients (mean age: 56.1 ± 18.1) who underwent 80 kVp CT venography (CTV) for the evaluation of deep vein thrombosis (DVT) during 4 months were enrolled in this retrospective study. The same raw data were reconstructed using FBP, ASIR, and MBIR. Objective and subjective image analysis were performed at the inferior vena cava (IVC), femoral vein, and popliteal vein. The mean CNR of MBIR was significantly greater than those of FBP and ASIR and images reconstructed using MBIR had significantly lower objective image noise (p <.001). Subjective image quality and confidence of detecting DVT by MBIR group were significantly greater than those of FBP and ASIR (p <.005), and MBIR had the lowest score for subjective image noise (p <.001). CTV at 80 kVp with MBIR was superior to FBP and ASIR regarding subjective and objective image qualities. (orig.)

  11. Mutual information as a measure of reconstruction quality in 3D dynamic lung EIT

    International Nuclear Information System (INIS)

    Crabb, M G; Lionheart, W R B; Davidson, J L; Wright, P; McCann, H; Little, R; Naish, J H; Parker, G J M; Kikinis, R

    2013-01-01

    We report on a pilot study with healthy subjects who had an MR scan in addition to EIT data acquired with the Manchester fEITER system. The MR images are used to inform the external shape of a 3D EIT reconstruction model of the thorax, and small changes in the boundary that occur during respiration are addressed by incorporating the sensitivity with respect to boundary shape into a robust reconstruction algorithm. A quantitative comparison of the image quality for different EIT reconstructions is achieved through calculation of their mutual information with a segmented MR image. A shape corrected reconstruction algorithm reduces boundary artefacts relative to a standard reconstruction, and has a greater mutual information of approximately 4% with the segmented MR image.

  12. Quality Analysis on 3d Buidling Models Reconstructed from Uav Imagery

    Science.gov (United States)

    Jarzabek-Rychard, M.; Karpina, M.

    2016-06-01

    Recent developments in UAV technology and structure from motion techniques have effected that UAVs are becoming standard platforms for 3D data collection. Because of their flexibility and ability to reach inaccessible urban parts, drones appear as optimal solution for urban applications. Building reconstruction from the data collected with UAV has the important potential to reduce labour cost for fast update of already reconstructed 3D cities. However, especially for updating of existing scenes derived from different sensors (e.g. airborne laser scanning), a proper quality assessment is necessary. The objective of this paper is thus to evaluate the potential of UAV imagery as an information source for automatic 3D building modeling at LOD2. The investigation process is conducted threefold: (1) comparing generated SfM point cloud to ALS data; (2) computing internal consistency measures of the reconstruction process; (3) analysing the deviation of Check Points identified on building roofs and measured with a tacheometer. In order to gain deep insight in the modeling performance, various quality indicators are computed and analysed. The assessment performed according to the ground truth shows that the building models acquired with UAV-photogrammetry have the accuracy of less than 18 cm for the plannimetric position and about 15 cm for the height component.

  13. QUALITY ANALYSIS ON 3D BUIDLING MODELS RECONSTRUCTED FROM UAV IMAGERY

    Directory of Open Access Journals (Sweden)

    M. Jarzabek-Rychard

    2016-06-01

    Full Text Available Recent developments in UAV technology and structure from motion techniques have effected that UAVs are becoming standard platforms for 3D data collection. Because of their flexibility and ability to reach inaccessible urban parts, drones appear as optimal solution for urban applications. Building reconstruction from the data collected with UAV has the important potential to reduce labour cost for fast update of already reconstructed 3D cities. However, especially for updating of existing scenes derived from different sensors (e.g. airborne laser scanning, a proper quality assessment is necessary. The objective of this paper is thus to evaluate the potential of UAV imagery as an information source for automatic 3D building modeling at LOD2. The investigation process is conducted threefold: (1 comparing generated SfM point cloud to ALS data; (2 computing internal consistency measures of the reconstruction process; (3 analysing the deviation of Check Points identified on building roofs and measured with a tacheometer. In order to gain deep insight in the modeling performance, various quality indicators are computed and analysed. The assessment performed according to the ground truth shows that the building models acquired with UAV-photogrammetry have the accuracy of less than 18 cm for the plannimetric position and about 15 cm for the height component.

  14. Influence of sampling interval and number of projections on the quality of SR-XFMT reconstruction

    International Nuclear Information System (INIS)

    Deng Biao; Yu Xiaohan; Xu Hongjie

    2007-01-01

    Synchrotron Radiation based X-ray Fluorescent Microtomography (SR-XFMT) is a nondestructive technique for detecting elemental composition and distribution inside a specimen with high spatial resolution and sensitivity. In this paper, computer simulation of SR-XFMT experiment is performed. The influence of the sampling interval and the number of projections on the quality of SR-XFMT image reconstruction is analyzed. It is found that the sampling interval has greater effect on the quality of reconstruction than the number of projections. (authors)

  15. Increasing reconstruction quality of diffractive optical elements displayed with LC SLM

    Science.gov (United States)

    Cheremkhin, Pavel A.; Evtikhiev, Nikolay N.; Krasnov, Vitaly V.; Rodin, Vladislav G.; Starikov, Sergey N.

    2015-03-01

    Phase liquid crystal (LC) spatial light modulators (SLM) are actively used in various applications. However, majority of scientific applications require stable phase modulation which might be hard to achieve with commercially available SLM due to its consumer origin. The use of digital voltage addressing scheme leads to phase temporal fluctuations, which results in lower diffraction efficiency and reconstruction quality of displayed diffractive optical elements (DOE). Due to high periodicity of fluctuations it should be possible to use knowledge of these fluctuations during DOE synthesis to minimize negative effect. We synthesized DOE using accurately measured phase fluctuations of phase LC SLM "HoloEye PLUTO VIS" to minimize its negative impact on displayed DOE reconstruction. Synthesis was conducted with versatile direct search with random trajectory (DSRT) method in the following way. Before DOE synthesis begun, two-dimensional dependency of SLM phase shift on addressed signal level and time from frame start was obtained. Then synthesis begins. First, initial phase distribution is created. Second, random trajectory of consecutive processing of all DOE elements is generated. Then iterative process begins. Each DOE element sequentially has its value changed to one that provides better value of objective criterion, e.g. lower deviation of reconstructed image from original one. If current element value provides best objective criterion value then it left unchanged. After all elements are processed, iteration repeats until stagnation is reached. It is demonstrated that application of SLM phase fluctuations knowledge in DOE synthesis with DSRT method leads to noticeable increase of DOE reconstruction quality.

  16. Prompt data reconstruction at the ATLAS experiment

    International Nuclear Information System (INIS)

    Andrew Stewart, Graeme; Boyd, Jamie; Unal, Guillaume; Firmino da Costa, João; Tuggle, Joseph

    2012-01-01

    The ATLAS experiment at the LHC collider recorded more than 5 fb −1 data of pp collisions at a centre-of-mass energy of 7 TeV during 2011. The recorded data are promptly reconstructed in two steps at a large computing farm at CERN to provide fast access to high quality data for physics analysis. In the first step, a subset of the data, corresponding to the express stream and having 10Hz of events, is processed in parallel with data taking. Data quality, detector calibration constants, and the beam spot position are determined using the reconstructed data within 48 hours. In the second step all recorded data are processed with the updated parameters. The LHC significantly increased the instantaneous luminosity and the number of interactions per bunch crossing in 2011; the data recording rate by ATLAS exceeds 400 Hz. To cope with these challenges the performance and reliability of the ATLAS reconstruction software have been improved. In this paper we describe how the prompt data reconstruction system quickly and stably provides high quality data to analysers.

  17. Volume reconstruction optimization for tomo-PIV algorithms applied to experimental data

    Science.gov (United States)

    Martins, Fabio J. W. A.; Foucaut, Jean-Marc; Thomas, Lionel; Azevedo, Luis F. A.; Stanislas, Michel

    2015-08-01

    Tomographic PIV is a three-component volumetric velocity measurement technique based on the tomographic reconstruction of a particle distribution imaged by multiple camera views. In essence, the performance and accuracy of this technique is highly dependent on the parametric adjustment and the reconstruction algorithm used. Although synthetic data have been widely employed to optimize experiments, the resulting reconstructed volumes might not have optimal quality. The purpose of the present study is to offer quality indicators that can be applied to data samples in order to improve the quality of velocity results obtained by the tomo-PIV technique. The methodology proposed can potentially lead to significantly reduction in the time required to optimize a tomo-PIV reconstruction, also leading to better quality velocity results. Tomo-PIV data provided by a six-camera turbulent boundary-layer experiment were used to optimize the reconstruction algorithms according to this methodology. Velocity statistics measurements obtained by optimized BIMART, SMART and MART algorithms were compared with hot-wire anemometer data and velocity measurement uncertainties were computed. Results indicated that BIMART and SMART algorithms produced reconstructed volumes with equivalent quality as the standard MART with the benefit of reduced computational time.

  18. Volume reconstruction optimization for tomo-PIV algorithms applied to experimental data

    International Nuclear Information System (INIS)

    Martins, Fabio J W A; Foucaut, Jean-Marc; Stanislas, Michel; Thomas, Lionel; Azevedo, Luis F A

    2015-01-01

    Tomographic PIV is a three-component volumetric velocity measurement technique based on the tomographic reconstruction of a particle distribution imaged by multiple camera views. In essence, the performance and accuracy of this technique is highly dependent on the parametric adjustment and the reconstruction algorithm used. Although synthetic data have been widely employed to optimize experiments, the resulting reconstructed volumes might not have optimal quality. The purpose of the present study is to offer quality indicators that can be applied to data samples in order to improve the quality of velocity results obtained by the tomo-PIV technique. The methodology proposed can potentially lead to significantly reduction in the time required to optimize a tomo-PIV reconstruction, also leading to better quality velocity results. Tomo-PIV data provided by a six-camera turbulent boundary-layer experiment were used to optimize the reconstruction algorithms according to this methodology. Velocity statistics measurements obtained by optimized BIMART, SMART and MART algorithms were compared with hot-wire anemometer data and velocity measurement uncertainties were computed. Results indicated that BIMART and SMART algorithms produced reconstructed volumes with equivalent quality as the standard MART with the benefit of reduced computational time. (paper)

  19. Image improvement and three-dimensional reconstruction using holographic image processing

    Science.gov (United States)

    Stroke, G. W.; Halioua, M.; Thon, F.; Willasch, D. H.

    1977-01-01

    Holographic computing principles make possible image improvement and synthesis in many cases of current scientific and engineering interest. Examples are given for the improvement of resolution in electron microscopy and 3-D reconstruction in electron microscopy and X-ray crystallography, following an analysis of optical versus digital computing in such applications.

  20. Multi-slice spiral CT coronary angiography: influence of heart rate and reconstruction window on image quality

    International Nuclear Information System (INIS)

    Mao Dingbiao; Hua Yanqing; Wang Mingpeng; Zhang Guozhen; Wu Weilan; Hu Fei; Ge Xiaojun; Ding Qiyong

    2004-01-01

    Objective: To evaluate the influence of heart rate and reconstruction window on image quality of multi-slice spiral CT coronary angiography. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 80 healthy cases. Results: Four coronary (RCA, LM, LAD, LCX) segments were analyzed in each patient with regard to image quality. 82.1% (46/56) of the coronary segments were sufficient for analysis in patients with heart rate ≤60 bpm, 63.4% (104/164) with 61-70 bpm, 41.2%(28/68) with 71-80 bpm, and 31.2%(10/32) with>80 bpm, respectively. The left anterior descending artery, left circumflex artery, and the right coronary artery were best visualized when the reconstruction window was 60%-70%, 50%-60%, and 50%-70%, respectively. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate and reconstruction window

  1. Influence of model based iterative reconstruction algorithm on image quality of multiplanar reformations in reduced dose chest CT

    International Nuclear Information System (INIS)

    Barras, Heloise; Dunet, Vincent; Hachulla, Anne-Lise; Grimm, Jochen; Beigelman-Aubry, Catherine

    2016-01-01

    Model-based iterative reconstruction (MBIR) reduces image noise and improves image quality (IQ) but its influence on post-processing tools including maximal intensity projection (MIP) and minimal intensity projection (mIP) remains unknown. To evaluate the influence on IQ of MBIR on native, mIP, MIP axial and coronal reformats of reduced dose computed tomography (RD-CT) chest acquisition. Raw data of 50 patients, who underwent a standard dose CT (SD-CT) and a follow-up RD-CT with a CT dose index (CTDI) of 2–3 mGy, were reconstructed by MBIR and FBP. Native slices, 4-mm-thick MIP, and 3-mm-thick mIP axial and coronal reformats were generated. The relative IQ, subjective IQ, image noise, and number of artifacts were determined in order to compare different reconstructions of RD-CT with reference SD-CT. The lowest noise was observed with MBIR. RD-CT reconstructed by MBIR exhibited the best relative and subjective IQ on coronal view regardless of the post-processing tool. MBIR generated the lowest rate of artefacts on coronal mIP/MIP reformats and the highest one on axial reformats, mainly represented by distortions and stairsteps artifacts. The MBIR algorithm reduces image noise but generates more artifacts than FBP on axial mIP and MIP reformats of RD-CT. Conversely, it significantly improves IQ on coronal views, without increasing artifacts, regardless of the post-processing technique

  2. Influence of iterative image reconstruction on CT-based calcium score measurements

    NARCIS (Netherlands)

    van Osch, Jochen A. C.; Mouden, Mohamed; van Dalen, Jorn A.; Timmer, Jorik R.; Reiffers, Stoffer; Knollema, Siert; Greuter, Marcel J. W.; Ottervanger, Jan Paul; Jager, Piet L.

    Iterative reconstruction techniques for coronary CT angiography have been introduced as an alternative for traditional filter back projection (FBP) to reduce image noise, allowing improved image quality and a potential for dose reduction. However, the impact of iterative reconstruction on the

  3. Continuous quality improvement

    International Nuclear Information System (INIS)

    Bourne, P.B.

    1985-01-01

    This paper describes the various statistical tools used at the Hanford Engineering Development Laboratory to achieve continuous quality improvement in the development of Breeder Reactor Technology and in reactor operations. The role of the quality assurance professionals in this process, including quantifiable measurements using actual examples, is provided. The commitment to quality improvement through top management involvement is dramatically illustrated

  4. MO-DE-207A-07: Filtered Iterative Reconstruction (FIR) Via Proximal Forward-Backward Splitting: A Synergy of Analytical and Iterative Reconstruction Method for CT

    International Nuclear Information System (INIS)

    Gao, H

    2016-01-01

    Purpose: This work is to develop a general framework, namely filtered iterative reconstruction (FIR) method, to incorporate analytical reconstruction (AR) method into iterative reconstruction (IR) method, for enhanced CT image quality. Methods: FIR is formulated as a combination of filtered data fidelity and sparsity regularization, and then solved by proximal forward-backward splitting (PFBS) algorithm. As a result, the image reconstruction decouples data fidelity and image regularization with a two-step iterative scheme, during which an AR-projection step updates the filtered data fidelity term, while a denoising solver updates the sparsity regularization term. During the AR-projection step, the image is projected to the data domain to form the data residual, and then reconstructed by certain AR to a residual image which is in turn weighted together with previous image iterate to form next image iterate. Since the eigenvalues of AR-projection operator are close to the unity, PFBS based FIR has a fast convergence. Results: The proposed FIR method is validated in the setting of circular cone-beam CT with AR being FDK and total-variation sparsity regularization, and has improved image quality from both AR and IR. For example, AIR has improved visual assessment and quantitative measurement in terms of both contrast and resolution, and reduced axial and half-fan artifacts. Conclusion: FIR is proposed to incorporate AR into IR, with an efficient image reconstruction algorithm based on PFBS. The CBCT results suggest that FIR synergizes AR and IR with improved image quality and reduced axial and half-fan artifacts. The authors was partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000), and the Shanghai Pujiang Talent Program (#14PJ1404500).

  5. Comparing and improving reconstruction methods for proxies based on compositional data

    Science.gov (United States)

    Nolan, C.; Tipton, J.; Booth, R.; Jackson, S. T.; Hooten, M.

    2017-12-01

    Many types of studies in paleoclimatology and paleoecology involve compositional data. Often, these studies aim to use compositional data to reconstruct an environmental variable of interest; the reconstruction is usually done via the development of a transfer function. Transfer functions have been developed using many different methods. Existing methods tend to relate the compositional data and the reconstruction target in very simple ways. Additionally, the results from different methods are rarely compared. Here we seek to address these two issues. First, we introduce a new hierarchical Bayesian multivariate gaussian process model; this model allows for the relationship between each species in the compositional dataset and the environmental variable to be modeled in a way that captures the underlying complexities. Then, we compare this new method to machine learning techniques and commonly used existing methods. The comparisons are based on reconstructing the water table depth history of Caribou Bog (an ombrotrophic Sphagnum peat bog in Old Town, Maine, USA) from a new 7500 year long record of testate amoebae assemblages. The resulting reconstructions from different methods diverge in both their resulting means and uncertainties. In particular, uncertainty tends to be drastically underestimated by some common methods. These results will help to improve inference of water table depth from testate amoebae. Furthermore, this approach can be applied to test and improve inferences of past environmental conditions from a broad array of paleo-proxies based on compositional data

  6. Ultralow-dose CT of the craniofacial bone for navigated surgery using adaptive statistical iterative reconstruction and model-based iterative reconstruction: 2D and 3D image quality.

    Science.gov (United States)

    Widmann, Gerlig; Schullian, Peter; Gassner, Eva-Maria; Hoermann, Romed; Bale, Reto; Puelacher, Wolfgang

    2015-03-01

    OBJECTIVE. The purpose of this article is to evaluate 2D and 3D image quality of high-resolution ultralow-dose CT images of the craniofacial bone for navigated surgery using adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in comparison with standard filtered backprojection (FBP). MATERIALS AND METHODS. A formalin-fixed human cadaver head was scanned using a clinical reference protocol at a CT dose index volume of 30.48 mGy and a series of five ultralow-dose protocols at 3.48, 2.19, 0.82, 0.44, and 0.22 mGy using FBP and ASIR at 50% (ASIR-50), ASIR at 100% (ASIR-100), and MBIR. Blinded 2D axial and 3D volume-rendered images were compared with each other by three readers using top-down scoring. Scores were analyzed per protocol or dose and reconstruction. All images were compared with the FBP reference at 30.48 mGy. A nonparametric Mann-Whitney U test was used. Statistical significance was set at p ASIR-100 at 3.48 mGy, ASIR-100 at 2.19 mGy, and MBIR at 0.82 mGy. MBIR at 2.19 and 3.48 mGy scored statistically significantly better than the FBP reference (p = 0.032 and 0.001, respectively). For 3D images, the FBP reference at 30.48 mGy did not statistically significantly differ from all reconstructions at 3.48 mGy; FBP and ASIR-100 at 2.19 mGy; FBP, ASIR-100, and MBIR at 0.82 mGy; MBIR at 0.44 mGy; and MBIR at 0.22 mGy. CONCLUSION. MBIR (2D and 3D) and ASIR-100 (2D) may significantly improve subjective image quality of ultralow-dose images and may allow more than 90% dose reductions.

  7. Online dose reconstruction for tracked volumetric arc therapy: Real-time implementation and offline quality assurance for prostate SBRT.

    Science.gov (United States)

    Kamerling, Cornelis Ph; Fast, Martin F; Ziegenhein, Peter; Menten, Martin J; Nill, Simeon; Oelfke, Uwe

    2017-11-01

    Firstly, this study provides a real-time implementation of online dose reconstruction for tracked volumetric arc therapy (VMAT). Secondly, this study describes a novel offline quality assurance tool, based on commercial dose calculation algorithms. Online dose reconstruction for VMAT is a computationally challenging task in terms of computer memory usage and calculation speed. To potentially reduce the amount of memory used, we analyzed the impact of beam angle sampling for dose calculation on the accuracy of the dose distribution. To establish the performance of the method, we planned two single-arc VMAT prostate stereotactic body radiation therapy cases for delivery with dynamic MLC tracking. For quality assurance of our online dose reconstruction method we have also developed a stand-alone offline dose reconstruction tool, which utilizes the RayStation treatment planning system to calculate dose. For the online reconstructed dose distributions of the tracked deliveries, we could establish strong resemblance for 72 and 36 beam co-planar equidistant beam samples with less than 1.2% deviation for the assessed dose-volume indicators (clinical target volume D98 and D2, and rectum D2). We could achieve average runtimes of 28-31 ms per reported MLC aperture for both dose computation and accumulation, meeting our real-time requirement. To cross-validate the offline tool, we have compared the planned dose to the offline reconstructed dose for static deliveries and found excellent agreement (3%/3 mm global gamma passing rates of 99.8%-100%). Being able to reconstruct dose during delivery enables online quality assurance and online replanning strategies for VMAT. The offline quality assurance tool provides the means to validate novel online dose reconstruction applications using a commercial dose calculation engine. © 2017 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  8. Preliminary investigations of equilibrium reconstruction quality during ELMy and ELM-free phases on JET

    International Nuclear Information System (INIS)

    Gelfusa, M.; Murari, A.; Peluso, E.; Gaudio, P.; Orsitto, F.P.; Gerasimov, S.

    2013-01-01

    On JET, the magnetic topology is normally derived from the code EFIT, which solves the Grad–Shafranov equation with constraints imposed by the available measurements, typically the pick-up coils. Both the code and the measurements are expected to perform worse during ELMs. To assess this hypothesis, various statistical indicators, based on the values of the residuals and their probability distribution, have been calculated. They all show that the quality of EFIT reconstructions is clearly better in absence of ELMs. How the responsibility, for the lower quality of the reconstructions, is shared between the measurements and EFIT is a subject under investigation. © 2001 Elsevier Science. All rights reserved

  9. The CMS Data Quality Monitoring software experience and future improvements

    CERN Document Server

    De Guio, Federico

    2013-01-01

    The Data Quality Monitoring (DQM) Software proved to be a central tool in the CMS experiment. Its flexibility allowed its integration in several environments Online, for real-time detector monitoring; Offline, for the final, fine-grained Data Certification; Release Validation, to constantly validate the functionality and the performance of the reconstruction software; in Monte Carlo productions. The central tool to deliver Data Quality information is a web site for browsing data quality histograms (DQM GUI). In this contribution the usage of the DQM Software in the different environments and its integration in the CMS Reconstruction Software Framework and in all production workflows are presented.

  10. Improving tritium exposure reconstructions using accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Love, A.H.; Hunt, J.R.; Vogel, J.S.; Knezovich, J.P.

    2004-01-01

    Direct measurement of tritium atoms by accelerator mass spectrometry (AMS) enables rapid low-activity tritium measurements from milligram-sized samples and permits greater ease of sample collection, faster throughput, and increased spatial and/or temporal resolution. Because existing methodologies for quantifying tritium have some significant limitations, the development of tritium AMS has allowed improvements in reconstructing tritium exposure concentrations from environmental measurements and provides an important additional tool in assessing the temporal and spatial distribution of chronic exposure. Tritium exposure reconstructions using AMS were previously demonstrated for a tree growing on known levels of tritiated water and for trees exposed to atmospheric releases of tritiated water vapor. In these analyses, tritium levels were measured from milligram-sized samples with sample preparation times of a few days. Hundreds of samples were analyzed within a few months of sample collection and resulted in the reconstruction of spatial and temporal exposure from tritium releases. Although the current quantification limit of tritium AMS is not adequate to determine natural environmental variations in tritium concentrations, it is expected to be sufficient for studies assessing possible health effects from chronic environmental tritium exposure. (orig.)

  11. Improving tritium exposure reconstructions using accelerator mass spectrometry

    Science.gov (United States)

    Hunt, J. R.; Vogel, J. S.; Knezovich, J. P.

    2010-01-01

    Direct measurement of tritium atoms by accelerator mass spectrometry (AMS) enables rapid low-activity tritium measurements from milligram-sized samples and permits greater ease of sample collection, faster throughput, and increased spatial and/or temporal resolution. Because existing methodologies for quantifying tritium have some significant limitations, the development of tritium AMS has allowed improvements in reconstructing tritium exposure concentrations from environmental measurements and provides an important additional tool in assessing the temporal and spatial distribution of chronic exposure. Tritium exposure reconstructions using AMS were previously demonstrated for a tree growing on known levels of tritiated water and for trees exposed to atmospheric releases of tritiated water vapor. In these analyses, tritium levels were measured from milligram-sized samples with sample preparation times of a few days. Hundreds of samples were analyzed within a few months of sample collection and resulted in the reconstruction of spatial and temporal exposure from tritium releases. Although the current quantification limit of tritium AMS is not adequate to determine natural environmental variations in tritium concentrations, it is expected to be sufficient for studies assessing possible health effects from chronic environmental tritium exposure. PMID:14735274

  12. Improved image quality in pinhole SPECT by accurate modeling of the point spread function in low magnification systems

    International Nuclear Information System (INIS)

    Pino, Francisco; Roé, Nuria; Aguiar, Pablo; Falcon, Carles; Ros, Domènec; Pavía, Javier

    2015-01-01

    Purpose: Single photon emission computed tomography (SPECT) has become an important noninvasive imaging technique in small-animal research. Due to the high resolution required in small-animal SPECT systems, the spatially variant system response needs to be included in the reconstruction algorithm. Accurate modeling of the system response should result in a major improvement in the quality of reconstructed images. The aim of this study was to quantitatively assess the impact that an accurate modeling of spatially variant collimator/detector response has on image-quality parameters, using a low magnification SPECT system equipped with a pinhole collimator and a small gamma camera. Methods: Three methods were used to model the point spread function (PSF). For the first, only the geometrical pinhole aperture was included in the PSF. For the second, the septal penetration through the pinhole collimator was added. In the third method, the measured intrinsic detector response was incorporated. Tomographic spatial resolution was evaluated and contrast, recovery coefficients, contrast-to-noise ratio, and noise were quantified using a custom-built NEMA NU 4–2008 image-quality phantom. Results: A high correlation was found between the experimental data corresponding to intrinsic detector response and the fitted values obtained by means of an asymmetric Gaussian distribution. For all PSF models, resolution improved as the distance from the point source to the center of the field of view increased and when the acquisition radius diminished. An improvement of resolution was observed after a minimum of five iterations when the PSF modeling included more corrections. Contrast, recovery coefficients, and contrast-to-noise ratio were better for the same level of noise in the image when more accurate models were included. Ring-type artifacts were observed when the number of iterations exceeded 12. Conclusions: Accurate modeling of the PSF improves resolution, contrast, and recovery

  13. Improved image quality in pinhole SPECT by accurate modeling of the point spread function in low magnification systems

    Energy Technology Data Exchange (ETDEWEB)

    Pino, Francisco [Unitat de Biofísica, Facultat de Medicina, Universitat de Barcelona, Barcelona 08036, Spain and Servei de Física Mèdica i Protecció Radiològica, Institut Català d’Oncologia, L’Hospitalet de Llobregat 08907 (Spain); Roé, Nuria [Unitat de Biofísica, Facultat de Medicina, Universitat de Barcelona, Barcelona 08036 (Spain); Aguiar, Pablo, E-mail: pablo.aguiar.fernandez@sergas.es [Fundación Ramón Domínguez, Complexo Hospitalario Universitario de Santiago de Compostela 15706, Spain and Grupo de Imagen Molecular, Instituto de Investigacións Sanitarias de Santiago de Compostela (IDIS), Galicia 15782 (Spain); Falcon, Carles; Ros, Domènec [Institut d’Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona 08036, Spain and CIBER en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona 08036 (Spain); Pavía, Javier [Institut d’Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona 080836 (Spain); CIBER en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona 08036 (Spain); and Servei de Medicina Nuclear, Hospital Clínic, Barcelona 08036 (Spain)

    2015-02-15

    Purpose: Single photon emission computed tomography (SPECT) has become an important noninvasive imaging technique in small-animal research. Due to the high resolution required in small-animal SPECT systems, the spatially variant system response needs to be included in the reconstruction algorithm. Accurate modeling of the system response should result in a major improvement in the quality of reconstructed images. The aim of this study was to quantitatively assess the impact that an accurate modeling of spatially variant collimator/detector response has on image-quality parameters, using a low magnification SPECT system equipped with a pinhole collimator and a small gamma camera. Methods: Three methods were used to model the point spread function (PSF). For the first, only the geometrical pinhole aperture was included in the PSF. For the second, the septal penetration through the pinhole collimator was added. In the third method, the measured intrinsic detector response was incorporated. Tomographic spatial resolution was evaluated and contrast, recovery coefficients, contrast-to-noise ratio, and noise were quantified using a custom-built NEMA NU 4–2008 image-quality phantom. Results: A high correlation was found between the experimental data corresponding to intrinsic detector response and the fitted values obtained by means of an asymmetric Gaussian distribution. For all PSF models, resolution improved as the distance from the point source to the center of the field of view increased and when the acquisition radius diminished. An improvement of resolution was observed after a minimum of five iterations when the PSF modeling included more corrections. Contrast, recovery coefficients, and contrast-to-noise ratio were better for the same level of noise in the image when more accurate models were included. Ring-type artifacts were observed when the number of iterations exceeded 12. Conclusions: Accurate modeling of the PSF improves resolution, contrast, and recovery

  14. Coronary artery plaques: Cardiac CT with model-based and adaptive-statistical iterative reconstruction technique

    International Nuclear Information System (INIS)

    Scheffel, Hans; Stolzmann, Paul; Schlett, Christopher L.; Engel, Leif-Christopher; Major, Gyöngi Petra; Károlyi, Mihály; Do, Synho; Maurovich-Horvat, Pál; Hoffmann, Udo

    2012-01-01

    Objectives: To compare image quality of coronary artery plaque visualization at CT angiography with images reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model based iterative reconstruction (MBIR) techniques. Methods: The coronary arteries of three ex vivo human hearts were imaged by CT and reconstructed with FBP, ASIR and MBIR. Coronary cross-sectional images were co-registered between the different reconstruction techniques and assessed for qualitative and quantitative image quality parameters. Readers were blinded to the reconstruction algorithm. Results: A total of 375 triplets of coronary cross-sectional images were co-registered. Using MBIR, 26% of the images were rated as having excellent overall image quality, which was significantly better as compared to ASIR and FBP (4% and 13%, respectively, all p < 0.001). Qualitative assessment of image noise demonstrated a noise reduction by using ASIR as compared to FBP (p < 0.01) and further noise reduction by using MBIR (p < 0.001). The contrast-to-noise-ratio (CNR) using MBIR was better as compared to ASIR and FBP (44 ± 19, 29 ± 15, 26 ± 9, respectively; all p < 0.001). Conclusions: Using MBIR improved image quality, reduced image noise and increased CNR as compared to the other available reconstruction techniques. This may further improve the visualization of coronary artery plaque and allow radiation reduction.

  15. Quality improvement - the future begins

    International Nuclear Information System (INIS)

    Boissy, G.J.

    1987-01-01

    The comprehensive quality improvement program of the Florida Power and Light Co. is described: management commitment, quality improvement process, quality improvement teams, policy development, and quality in daily work are discussed

  16. Improving parallel imaging by jointly reconstructing multi-contrast data.

    Science.gov (United States)

    Bilgic, Berkin; Kim, Tae Hyung; Liao, Congyu; Manhard, Mary Kate; Wald, Lawrence L; Haldar, Justin P; Setsompop, Kawin

    2018-08-01

    To develop parallel imaging techniques that simultaneously exploit coil sensitivity encoding, image phase prior information, similarities across multiple images, and complementary k-space sampling for highly accelerated data acquisition. We introduce joint virtual coil (JVC)-generalized autocalibrating partially parallel acquisitions (GRAPPA) to jointly reconstruct data acquired with different contrast preparations, and show its application in 2D, 3D, and simultaneous multi-slice (SMS) acquisitions. We extend the joint parallel imaging concept to exploit limited support and smooth phase constraints through Joint (J-) LORAKS formulation. J-LORAKS allows joint parallel imaging from limited autocalibration signal region, as well as permitting partial Fourier sampling and calibrationless reconstruction. We demonstrate highly accelerated 2D balanced steady-state free precession with phase cycling, SMS multi-echo spin echo, 3D multi-echo magnetization-prepared rapid gradient echo, and multi-echo gradient recalled echo acquisitions in vivo. Compared to conventional GRAPPA, proposed joint acquisition/reconstruction techniques provide more than 2-fold reduction in reconstruction error. JVC-GRAPPA takes advantage of additional spatial encoding from phase information and image similarity, and employs different sampling patterns across acquisitions. J-LORAKS achieves a more parsimonious low-rank representation of local k-space by considering multiple images as additional coils. Both approaches provide dramatic improvement in artifact and noise mitigation over conventional single-contrast parallel imaging reconstruction. Magn Reson Med 80:619-632, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  17. Regularization design for high-quality cone-beam CT of intracranial hemorrhage using statistical reconstruction

    Science.gov (United States)

    Dang, H.; Stayman, J. W.; Xu, J.; Sisniega, A.; Zbijewski, W.; Wang, X.; Foos, D. H.; Aygun, N.; Koliatsos, V. E.; Siewerdsen, J. H.

    2016-03-01

    Intracranial hemorrhage (ICH) is associated with pathologies such as hemorrhagic stroke and traumatic brain injury. Multi-detector CT is the current front-line imaging modality for detecting ICH (fresh blood contrast 40-80 HU, down to 1 mm). Flat-panel detector (FPD) cone-beam CT (CBCT) offers a potential alternative with a smaller scanner footprint, greater portability, and lower cost potentially well suited to deployment at the point of care outside standard diagnostic radiology and emergency room settings. Previous studies have suggested reliable detection of ICH down to 3 mm in CBCT using high-fidelity artifact correction and penalized weighted least-squared (PWLS) image reconstruction with a post-artifact-correction noise model. However, ICH reconstructed by traditional image regularization exhibits nonuniform spatial resolution and noise due to interaction between the statistical weights and regularization, which potentially degrades the detectability of ICH. In this work, we propose three regularization methods designed to overcome these challenges. The first two compute spatially varying certainty for uniform spatial resolution and noise, respectively. The third computes spatially varying regularization strength to achieve uniform "detectability," combining both spatial resolution and noise in a manner analogous to a delta-function detection task. Experiments were conducted on a CBCT test-bench, and image quality was evaluated for simulated ICH in different regions of an anthropomorphic head. The first two methods improved the uniformity in spatial resolution and noise compared to traditional regularization. The third exhibited the highest uniformity in detectability among all methods and best overall image quality. The proposed regularization provides a valuable means to achieve uniform image quality in CBCT of ICH and is being incorporated in a CBCT prototype for ICH imaging.

  18. [Qilin Pills for obstructive azoospermia after ejaculatory duct reconstruction].

    Science.gov (United States)

    Zhang, Lei; Gao, Ping; Ren, Fei-Qiang; Chang, De-Gui; Yu, Xu-Jun; Zhang, Pei-Hai

    2016-09-01

    To observe the clinical effect of Qilin Pills in the treatment of severe oligozoospermia after microsurgical ejaculatory duct reconstruction for obstructive azoospermia. We retrospectively analyzed 75 cases of obstructive azoospermia treated by ejaculatory duct reconstruction followed by administration of Qilin Pills. The patients were divided into a Qilin group (n=42) and a control group (n=33) postoperatively, treated with Qilin Pills and placebo, respectively. After 3 months of medication, we compared the sperm quality between the two groups of patients. After 3 months' treatment, all the patients experienced remarkable improvement in sperm quality (P0.05). The total effectiveness rate was higher in the Qilin group than in the controls (88.1% vs 72.7%), but with no significant difference between the two groups (P>0.05). Qilin Pills are fairly effective in improving the quantity of sperm in obstructive azoospermia patients after ejaculatory duct reconstruction.

  19. Adaptive statistical iterative reconstruction versus filtered back projection in the same patient: 64 channel liver CT image quality and patient radiation dose

    International Nuclear Information System (INIS)

    Mitsumori, Lee M.; Shuman, William P.; Busey, Janet M.; Kolokythas, Orpheus; Koprowicz, Kent M.

    2012-01-01

    To compare routine dose liver CT reconstructed with filtered back projection (FBP) versus low dose images reconstructed with FBP and adaptive statistical iterative reconstruction (ASIR). In this retrospective study, patients had a routine dose protocol reconstructed with FBP, and again within 17 months (median 6.1 months), had a low dose protocol reconstructed twice, with FBP and ASIR. These reconstructions were compared for noise, image quality, and radiation dose. Nineteen patients were included. (12 male, mean age 58). Noise was significantly lower in low dose images reconstructed with ASIR compared to routine dose images reconstructed with FBP (liver: p <.05, aorta: p < 0.001). Low dose FBP images were scored significantly lower for subjective image quality than low dose ASIR (2.1 ± 0.5, 3.2 ± 0.8, p < 0.001). There was no difference in subjective image quality scores between routine dose FBP images and low dose ASIR images (3.6 ± 0.5, 3.2 ± 0.8, NS).Radiation dose was 41% less for the low dose protocol (4.4 ± 2.4 mSv versus 7.5 ± 5.5 mSv, p < 0.05). Our initial results suggest low dose CT images reconstructed with ASIR may have lower measured noise, similar image quality, yet significantly less radiation dose compared with higher dose images reconstructed with FBP. (orig.)

  20. Adaptive statistical iterative reconstruction versus filtered back projection in the same patient: 64 channel liver CT image quality and patient radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Mitsumori, Lee M.; Shuman, William P.; Busey, Janet M.; Kolokythas, Orpheus; Koprowicz, Kent M. [University of Washington School of Medicine, Department of Radiology, Seattle, WA (United States)

    2012-01-15

    To compare routine dose liver CT reconstructed with filtered back projection (FBP) versus low dose images reconstructed with FBP and adaptive statistical iterative reconstruction (ASIR). In this retrospective study, patients had a routine dose protocol reconstructed with FBP, and again within 17 months (median 6.1 months), had a low dose protocol reconstructed twice, with FBP and ASIR. These reconstructions were compared for noise, image quality, and radiation dose. Nineteen patients were included. (12 male, mean age 58). Noise was significantly lower in low dose images reconstructed with ASIR compared to routine dose images reconstructed with FBP (liver: p <.05, aorta: p < 0.001). Low dose FBP images were scored significantly lower for subjective image quality than low dose ASIR (2.1 {+-} 0.5, 3.2 {+-} 0.8, p < 0.001). There was no difference in subjective image quality scores between routine dose FBP images and low dose ASIR images (3.6 {+-} 0.5, 3.2 {+-} 0.8, NS).Radiation dose was 41% less for the low dose protocol (4.4 {+-} 2.4 mSv versus 7.5 {+-} 5.5 mSv, p < 0.05). Our initial results suggest low dose CT images reconstructed with ASIR may have lower measured noise, similar image quality, yet significantly less radiation dose compared with higher dose images reconstructed with FBP. (orig.)

  1. Integrating multisensor satellite data merging and image reconstruction in support of machine learning for better water quality management.

    Science.gov (United States)

    Chang, Ni-Bin; Bai, Kaixu; Chen, Chi-Farn

    2017-10-01

    Monitoring water quality changes in lakes, reservoirs, estuaries, and coastal waters is critical in response to the needs for sustainable development. This study develops a remote sensing-based multiscale modeling system by integrating multi-sensor satellite data merging and image reconstruction algorithms in support of feature extraction with machine learning leading to automate continuous water quality monitoring in environmentally sensitive regions. This new Earth observation platform, termed "cross-mission data merging and image reconstruction with machine learning" (CDMIM), is capable of merging multiple satellite imageries to provide daily water quality monitoring through a series of image processing, enhancement, reconstruction, and data mining/machine learning techniques. Two existing key algorithms, including Spectral Information Adaptation and Synthesis Scheme (SIASS) and SMart Information Reconstruction (SMIR), are highlighted to support feature extraction and content-based mapping. Whereas SIASS can support various data merging efforts to merge images collected from cross-mission satellite sensors, SMIR can overcome data gaps by reconstructing the information of value-missing pixels due to impacts such as cloud obstruction. Practical implementation of CDMIM was assessed by predicting the water quality over seasons in terms of the concentrations of nutrients and chlorophyll-a, as well as water clarity in Lake Nicaragua, providing synergistic efforts to better monitor the aquatic environment and offer insightful lake watershed management strategies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Improved nanostructure reconstruction by performing data refinement in optical scatterometry

    Science.gov (United States)

    Zhu, Jinlong; Jiang, Hao; Shi, Yating; Chen, Xiuguo; Zhang, Chuanwei; Liu, Shiyuan

    2016-01-01

    Recently, we have indirectly demonstrated that nanostructure reconstruction accuracy is degraded by the outliers in optical scatterometry, and we have applied the robust estimation method to suppress these outliers. However, the existence of a possible heavy masking effect could result in the risk of low measurement accuracy, since the detection of outliers is simply based on the judgment of residual value. In this work, a novel method is introduced to directly detect outliers, which can provide the intuitional display of outliers in a two-dimensional coordinate system. Moreover, a robust correction step based on the principle of least trimmed squared estimator regression is proposed to replace the conventional Gauss-Newton iteration step, by which the more reliable and accurate nanostructure reconstruction is achieved. The improved reconstruction of a one-dimensional etched Si grating has demonstrated the feasibility of the proposed methods.

  3. Improved nanostructure reconstruction by performing data refinement in optical scatterometry

    International Nuclear Information System (INIS)

    Zhu, Jinlong; Jiang, Hao; Shi, Yating; Chen, Xiuguo; Zhang, Chuanwei; Liu, Shiyuan

    2016-01-01

    Recently, we have indirectly demonstrated that nanostructure reconstruction accuracy is degraded by the outliers in optical scatterometry, and we have applied the robust estimation method to suppress these outliers. However, the existence of a possible heavy masking effect could result in the risk of low measurement accuracy, since the detection of outliers is simply based on the judgment of residual value. In this work, a novel method is introduced to directly detect outliers, which can provide the intuitional display of outliers in a two-dimensional coordinate system. Moreover, a robust correction step based on the principle of least trimmed squared estimator regression is proposed to replace the conventional Gauss–Newton iteration step, by which the more reliable and accurate nanostructure reconstruction is achieved. The improved reconstruction of a one-dimensional etched Si grating has demonstrated the feasibility of the proposed methods. (paper)

  4. Definition of quality indicators in microsurgery in head and neck reconstruction based on a 5-year follow-up without a loss.

    Science.gov (United States)

    Kessler, P; Poort, L; Böckmann, R; Lethaus, B

    2013-01-01

    Microsurgical tissue transfer is a standard procedure in reconstructive surgery of defects in head and neck oncology patients. According to the literature vascular thrombosis occurs in 8-14% of cases and is considered to be the main reason for flap failure. A review of the literature on this subject was carried out and related to the quality guidelines of the Department of Cranio-Maxillofacial Surgery in the Maastricht University Medical Centre. We defined quality indicators and quality goals for the reconstruction of head and neck defects. We investigated whether or not these parameters are practicable in a specialized head and neck cancer unit. We included 81 consecutive patients with oral cancer/osteoradionecrosis of the mandible who received a microsurgical free tissue transfer for reconstruction. The patients were treated in our institution between August 2007 and December 2011. Patient data were collected in a prospective database. Follow-up was conducted in the Department of Cranio-Maxillofacial Surgery. Data were analysed for the defined reference groups, and the results were compared with the quality goals. Median follow-up was 29.1 (range 1-55) months. There were only six (7.4%) immediate complications leading to compromised flaps. Among the complications were four (5.0%) anastomosis-related complications and two haematomas (2.5%). There was no flap loss. Based on the quality goals we were able to reach an overall flap success rate of 100%. Most of the defined quality goals can be attained in a specialized head and neck unit. Careful patient selection, pharmacologic, non-pharmacologic and surgical measures for preventing thrombosis, such as meticulous micro-vascular surgery are considered to be essential. No consensus in the literature was found on how complications could best be prevented. The role of a standardized pre-, peri- and postoperative management is presented. The importance of thorough planning and the technical skill of the reconstructive

  5. Relationships of clinical protocols and reconstruction kernels with image quality and radiation dose in a 128-slice CT scanner: Study with an anthropomorphic and water phantom

    International Nuclear Information System (INIS)

    Paul, Jijo; Krauss, B.; Banckwitz, R.; Maentele, W.; Bauer, R.W.; Vogl, T.J.

    2012-01-01

    Research highlights: ► Clinical protocol, reconstruction kernel, reconstructed slice thickness, phantom diameter or the density of material it contains directly affects the image quality of DSCT. ► Dual energy protocol shows the lowest DLP compared to all other protocols examined. ► Dual-energy fused images show excellent image quality and the noise is same as that of single- or high-pitch mode protocol images. ► Advanced CT technology improves image quality and considerably reduce radiation dose. ► An important finding is the comparatively higher DLP of the dual-source high-pitch protocol compared to other single- or dual-energy protocols. - Abstract: Purpose: The aim of this study was to explore the relationship of scanning parameters (clinical protocols), reconstruction kernels and slice thickness with image quality and radiation dose in a DSCT. Materials and methods: The chest of an anthropomorphic phantom was scanned on a DSCT scanner (Siemens Somatom Definition flash) using different clinical protocols, including single- and dual-energy modes. Four scan protocols were investigated: 1) single-source 120 kV, 110 mA s, 2) single-source 100 kV, 180 mA s, 3) high-pitch 120 kV, 130 mA s and 4) dual-energy with 100/Sn140 kV, eff.mA s 89, 76. The automatic exposure control was switched off for all the scans and the CTDIvol selected was in between 7.12 and 7.37 mGy. The raw data were reconstructed using the reconstruction kernels B31f, B80f and B70f, and slice thicknesses were 1.0 mm and 5.0 mm. Finally, the same parameters and procedures were used for the scanning of water phantom. Friedman test and Wilcoxon-Matched-Pair test were used for statistical analysis. Results: The DLP based on the given CTDIvol values showed significantly lower exposure for protocol 4, when compared to protocol 1 (percent difference 5.18%), protocol 2 (percent diff. 4.51%), and protocol 3 (percent diff. 8.81%). The highest change in Hounsfield Units was observed with dual

  6. A cluster-randomised quality improvement study to improve two inpatient stroke quality indicators.

    Science.gov (United States)

    Williams, Linda; Daggett, Virginia; Slaven, James E; Yu, Zhangsheng; Sager, Danielle; Myers, Jennifer; Plue, Laurie; Woodward-Hagg, Heather; Damush, Teresa M

    2016-04-01

    Quality indicator collection and feedback improves stroke care. We sought to determine whether quality improvement training plus indicator feedback was more effective than indicator feedback alone in improving inpatient stroke indicators. We conducted a cluster-randomised quality improvement trial, randomising hospitals to quality improvement training plus indicator feedback versus indicator feedback alone to improve deep vein thrombosis (DVT) prophylaxis and dysphagia screening. Intervention sites received collaborative-based quality improvement training, external facilitation and indicator feedback. Control sites received only indicator feedback. We compared indicators pre-implementation (pre-I) to active implementation (active-I) and post-implementation (post-I) periods. We constructed mixed-effect logistic models of the two indicators with a random intercept for hospital effect, adjusting for patient, time, intervention and hospital variables. Patients at intervention sites (1147 admissions), had similar race, gender and National Institutes of Health Stroke Scale scores to control sites (1017 admissions). DVT prophylaxis improved more in intervention sites during active-I period (ratio of ORs 4.90, pimproved similarly in both groups during active-I, but control sites improved more in post-I period (ratio of ORs 0.67, p=0.04). In logistic models, the intervention was independently positively associated with DVT performance during active-I period, and negatively associated with dysphagia performance post-I period. Quality improvement training was associated with early DVT improvement, but the effect was not sustained over time and was not seen with dysphagia screening. External quality improvement programmes may quickly boost performance but their effect may vary by indicator and may not sustain over time. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Consistent reconstruction of 4D fetal heart ultrasound images to cope with fetal motion.

    Science.gov (United States)

    Tanner, Christine; Flach, Barbara; Eggenberger, Céline; Mattausch, Oliver; Bajka, Michael; Goksel, Orcun

    2017-08-01

    4D ultrasound imaging of the fetal heart relies on reconstructions from B-mode images. In the presence of fetal motion, current approaches suffer from artifacts, which are unrecoverable for single sweeps. We propose to use many sweeps and exploit the resulting redundancy to automatically recover from motion by reconstructing a 4D image which is consistent in phase, space, and time. An interactive visualization framework to view animated ultrasound slices from 4D reconstructions on arbitrary planes was developed using a magnetically tracked mock probe. We first quantified the performance of 10 4D reconstruction formulations on simulated data. Reconstructions of 14 in vivo sequences by a baseline, the current state-of-the-art, and the proposed approach were then visually ranked with respect to temporal quality on orthogonal views. Rankings from 5 observers showed that the proposed 4D reconstruction approach significantly improves temporal image quality in comparison with the baseline. The 4D reconstructions of the baseline and the proposed methods were then inspected interactively for accessibility to clinically important views and rated for their clinical usefulness by an ultrasound specialist in obstetrics and gynecology. The reconstructions by the proposed method were rated as 'very useful' in 71% and were statistically significantly more useful than the baseline reconstructions. Multi-sweep fetal heart ultrasound acquisitions in combination with consistent 4D image reconstruction improves quality as well as clinical usefulness of the resulting 4D images in the presence of fetal motion.

  8. A high-throughput system for high-quality tomographic reconstruction of large datasets at Diamond Light Source.

    Science.gov (United States)

    Atwood, Robert C; Bodey, Andrew J; Price, Stephen W T; Basham, Mark; Drakopoulos, Michael

    2015-06-13

    Tomographic datasets collected at synchrotrons are becoming very large and complex, and, therefore, need to be managed efficiently. Raw images may have high pixel counts, and each pixel can be multidimensional and associated with additional data such as those derived from spectroscopy. In time-resolved studies, hundreds of tomographic datasets can be collected in sequence, yielding terabytes of data. Users of tomographic beamlines are drawn from various scientific disciplines, and many are keen to use tomographic reconstruction software that does not require a deep understanding of reconstruction principles. We have developed Savu, a reconstruction pipeline that enables users to rapidly reconstruct data to consistently create high-quality results. Savu is designed to work in an 'orthogonal' fashion, meaning that data can be converted between projection and sinogram space throughout the processing workflow as required. The Savu pipeline is modular and allows processing strategies to be optimized for users' purposes. In addition to the reconstruction algorithms themselves, it can include modules for identification of experimental problems, artefact correction, general image processing and data quality assessment. Savu is open source, open licensed and 'facility-independent': it can run on standard cluster infrastructure at any institution.

  9. Model-based iterative reconstruction for reduction of radiation dose in abdominopelvic CT: comparison to adaptive statistical iterative reconstruction.

    Science.gov (United States)

    Yasaka, Koichiro; Katsura, Masaki; Akahane, Masaaki; Sato, Jiro; Matsuda, Izuru; Ohtomo, Kuni

    2013-12-01

    To evaluate dose reduction and image quality of abdominopelvic computed tomography (CT) reconstructed with model-based iterative reconstruction (MBIR) compared to adaptive statistical iterative reconstruction (ASIR). In this prospective study, 85 patients underwent referential-, low-, and ultralow-dose unenhanced abdominopelvic CT. Images were reconstructed with ASIR for low-dose (L-ASIR) and ultralow-dose CT (UL-ASIR), and with MBIR for ultralow-dose CT (UL-MBIR). Image noise was measured in the abdominal aorta and iliopsoas muscle. Subjective image analyses and a lesion detection study (adrenal nodules) were conducted by two blinded radiologists. A reference standard was established by a consensus panel of two different radiologists using referential-dose CT reconstructed with filtered back projection. Compared to low-dose CT, there was a 63% decrease in dose-length product with ultralow-dose CT. UL-MBIR had significantly lower image noise than L-ASIR and UL-ASIR (all pASIR and UL-ASIR (all pASIR in diagnostic acceptability (p>0.65), or diagnostic performance for adrenal nodules (p>0.87). MBIR significantly improves image noise and streak artifacts compared to ASIR, and can achieve radiation dose reduction without severely compromising image quality.

  10. Improvement of image quality and dose management in CT fluoroscopy by iterative 3D image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Grosser, Oliver S.; Kupitz, Dennis; Powerski, Maciej; Mohnike, Konrad; Ricke, Jens [University Hospital Magdeburg, Department of Radiology and Nuclear Medicine, Magdeburg (Germany); Wybranski, Christian [University Hospital Magdeburg, Department of Radiology and Nuclear Medicine, Magdeburg (Germany); University Hospital Cologne, Institute for Diagnostic and Interventional Radiology, Cologne (Germany); Pech, Maciej [University Hospital Magdeburg, Department of Radiology and Nuclear Medicine, Magdeburg (Germany); Medical University of Gdansk, Second Department of Radiology, Gdansk (Poland); Amthauer, Holger [University Hospital Magdeburg, Department of Radiology and Nuclear Medicine, Magdeburg (Germany); Charite, Department of Nuclear Medicine, Berlin (Germany)

    2017-09-15

    The objective of this study was to assess the influence of an iterative CT reconstruction algorithm (IA), newly available for CT-fluoroscopy (CTF), on image noise, readers' confidence and effective dose compared to filtered back projection (FBP). Data from 165 patients (FBP/IA = 82/74) with CTF in the thorax, abdomen and pelvis were included. Noise was analysed in a large-diameter vessel. The impact of reconstruction and variables (e.g. X-ray tube current I) influencing noise and effective dose were analysed by ANOVA and a pairwise t-test with Bonferroni-Holm correction. Noise and readers' confidence were evaluated by three readers. Noise was significantly influenced by reconstruction, I, body region and circumference (all p ≤ 0.0002). IA reduced the noise significantly compared to FBP (p = 0.02). The effect varied for body regions and circumferences (p ≤ 0.001). The effective dose was influenced by the reconstruction, body region, interventional procedure and I (all p ≤ 0.02). The inter-rater reliability for noise and readers' confidence was good (W ≥ 0.75, p < 0.0001). Noise and readers' confidence were significantly better in AIDR-3D compared to FBP (p ≤ 0.03). Generally, IA yielded a significant reduction of the median effective dose. The CTF reconstruction by IA showed a significant reduction in noise and effective dose while readers' confidence increased. (orig.)

  11. Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom

    International Nuclear Information System (INIS)

    Ryu, Young Jin; Choi, Young Hun; Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One; Ha, Seongmin

    2016-01-01

    CT of pediatric phantoms can provide useful guidance to the optimization of knowledge-based iterative reconstruction CT. To compare radiation dose and image quality of CT images obtained at different radiation doses reconstructed with knowledge-based iterative reconstruction, hybrid iterative reconstruction and filtered back-projection. We scanned a 5-year anthropomorphic phantom at seven levels of radiation. We then reconstructed CT data with knowledge-based iterative reconstruction (iterative model reconstruction [IMR] levels 1, 2 and 3; Philips Healthcare, Andover, MA), hybrid iterative reconstruction (iDose 4 , levels 3 and 7; Philips Healthcare, Andover, MA) and filtered back-projection. The noise, signal-to-noise ratio and contrast-to-noise ratio were calculated. We evaluated low-contrast resolutions and detectability by low-contrast targets and subjective and objective spatial resolutions by the line pairs and wire. With radiation at 100 peak kVp and 100 mAs (3.64 mSv), the relative doses ranged from 5% (0.19 mSv) to 150% (5.46 mSv). Lower noise and higher signal-to-noise, contrast-to-noise and objective spatial resolution were generally achieved in ascending order of filtered back-projection, iDose 4 levels 3 and 7, and IMR levels 1, 2 and 3, at all radiation dose levels. Compared with filtered back-projection at 100% dose, similar noise levels were obtained on IMR level 2 images at 24% dose and iDose 4 level 3 images at 50% dose, respectively. Regarding low-contrast resolution, low-contrast detectability and objective spatial resolution, IMR level 2 images at 24% dose showed comparable image quality with filtered back-projection at 100% dose. Subjective spatial resolution was not greatly affected by reconstruction algorithm. Reduced-dose IMR obtained at 0.92 mSv (24%) showed similar image quality to routine-dose filtered back-projection obtained at 3.64 mSv (100%), and half-dose iDose 4 obtained at 1.81 mSv. (orig.)

  12. Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom.

    Science.gov (United States)

    Ryu, Young Jin; Choi, Young Hun; Cheon, Jung-Eun; Ha, Seongmin; Kim, Woo Sun; Kim, In-One

    2016-03-01

    CT of pediatric phantoms can provide useful guidance to the optimization of knowledge-based iterative reconstruction CT. To compare radiation dose and image quality of CT images obtained at different radiation doses reconstructed with knowledge-based iterative reconstruction, hybrid iterative reconstruction and filtered back-projection. We scanned a 5-year anthropomorphic phantom at seven levels of radiation. We then reconstructed CT data with knowledge-based iterative reconstruction (iterative model reconstruction [IMR] levels 1, 2 and 3; Philips Healthcare, Andover, MA), hybrid iterative reconstruction (iDose(4), levels 3 and 7; Philips Healthcare, Andover, MA) and filtered back-projection. The noise, signal-to-noise ratio and contrast-to-noise ratio were calculated. We evaluated low-contrast resolutions and detectability by low-contrast targets and subjective and objective spatial resolutions by the line pairs and wire. With radiation at 100 peak kVp and 100 mAs (3.64 mSv), the relative doses ranged from 5% (0.19 mSv) to 150% (5.46 mSv). Lower noise and higher signal-to-noise, contrast-to-noise and objective spatial resolution were generally achieved in ascending order of filtered back-projection, iDose(4) levels 3 and 7, and IMR levels 1, 2 and 3, at all radiation dose levels. Compared with filtered back-projection at 100% dose, similar noise levels were obtained on IMR level 2 images at 24% dose and iDose(4) level 3 images at 50% dose, respectively. Regarding low-contrast resolution, low-contrast detectability and objective spatial resolution, IMR level 2 images at 24% dose showed comparable image quality with filtered back-projection at 100% dose. Subjective spatial resolution was not greatly affected by reconstruction algorithm. Reduced-dose IMR obtained at 0.92 mSv (24%) showed similar image quality to routine-dose filtered back-projection obtained at 3.64 mSv (100%), and half-dose iDose(4) obtained at 1.81 mSv.

  13. Adaptive statistical iterative reconstruction and Veo: assessment of image quality and diagnostic performance in CT colonography at various radiation doses.

    Science.gov (United States)

    Yoon, Min A; Kim, Se Hyung; Lee, Jeong Min; Woo, Hyoun Sik; Lee, Eun Sun; Ahn, Se Jin; Han, Joon Koo

    2012-01-01

    To evaluate the diagnostic performance of computed tomography (CT) colonography (CTC) reconstructed with different levels of adaptive statistical iterative reconstruction (ASiR, GE Healthcare) and Veo (model-based iterative reconstruction, GE Healthcare) at various tube currents in detection of polyps in porcine colon phantoms. Five porcine colon phantoms with 46 simulated polyps were scanned at different radiation doses (10, 30, and 50 mA s) and were reconstructed using filtered back projection (FBP), ASiR (20%, 40%, and 60%) and Veo. Eleven data sets for each phantom (10-mA s FBP, 10-mA s 20% ASiR, 10-mA s 40% ASiR, 10-mA s 60% ASiR, 10-mA s Veo, 30-mA s FBP, 30-mA s 20% ASiR, 30-mA s 40% ASiR, 30-mA s 60% ASiR, 30-mA s Veo, and 50-mA s FBP) yielded a total of 55 data sets. Polyp detection sensitivity and confidence level of 2 independent observers were evaluated with the McNemar test, the Fisher exact test, and receiver operating characteristic curve analysis. Comparative analyses of overall image quality score, measured image noise, and interpretation time were also performed. Per-polyp detection sensitivities and specificities were highest in 10-mA s Veo, 30-mA s FBP, 30-mA s 60% ASiR, and 50-mA s FBP (sensitivity, 100%; specificity, 100%). The area-under-the-curve values for the overall performance of each data set was also highest (1.000) at 50-mA s FBP, 30-mA s FBP, 30-mA s 60% ASiR, and 10-mA s Veo. Images reconstructed with ASiR showed statistically significant improvement in per-polyp detection sensitivity as the percent level of per-polyp sensitivity increased (10-mA s FBP vs 10-mA s 20% ASiR, P = 0.011; 10-mA s FBP vs 10-mA s 40% ASiR, P = 0.000; 10-mA s FBP vs 10-mA s 60% ASiR, P = 0.000; 10-mA s 20% ASiR vs 40% ASiR, P = 0.034). Overall image quality score was highest at 30-mA s Veo and 50-mA s FBP. The quantitative measurement of the image noise was lowest at 30-mA s Veo and second lowest at 10-mA s Veo. There was a trend of decrease in time

  14. Image Reconstruction Algorithm For Electrical Capacitance Tomography (ECT)

    International Nuclear Information System (INIS)

    Arko

    2001-01-01

    ). Most image reconstruction algorithms for electrical capacitance tomography (ECT) use sensitivity maps as weighting factors. The computation is fast, involving a simple multiply-and- accumulate (MAC) operation, but the resulting image suffers from blurring due to the soft-field effect of the sensor. This paper presents a low cost iterative method employing proportional thresholding, which improves image quality dramatically. The strategy for implementation, computational cost, and achievable speed is examined when using a personal computer (PC) and Digital Signal Processor (DSP). For PC implementation, Watcom C++ 10.6 and Visual C++ 5.0 compilers were used. The experimental results are compared to the images reconstructed by commercially available software. The new algorithm improves the image quality significantly at a cost of a few iterations. This technique can be readily exploited for online applications

  15. Gaussian mixture models and semantic gating improve reconstructions from human brain activity

    Directory of Open Access Journals (Sweden)

    Sanne eSchoenmakers

    2015-01-01

    Full Text Available Better acquisition protocols and analysis techniques are making it possible to use fMRI to obtain highly detailed visualizations of brain processes. In particular we focus on the reconstruction of natural images from BOLD responses in visual cortex. We expand our linear Gaussian framework for percept decoding with Gaussian mixture models to better represent the prior distribution of natural images. Reconstruction of such images then boils down to probabilistic inference in a hybrid Bayesian network. In our set-up, different mixture components correspond to different character categories. Our framework can automatically infer higher-order semantic categories from lower-level brain areas. Furthermore the framework can gate semantic information from higher-order brain areas to enforce the correct category during reconstruction. When categorical information is not available, we show that automatically learned clusters in the data give a similar improvement in reconstruction. The hybrid Bayesian network leads to highly accurate reconstructions in both supervised and unsupervised settings.

  16. A shape-based quality evaluation and reconstruction method for electrical impedance tomography.

    Science.gov (United States)

    Antink, Christoph Hoog; Pikkemaat, Robert; Malmivuo, Jaakko; Leonhardt, Steffen

    2015-06-01

    Linear methods of reconstruction play an important role in medical electrical impedance tomography (EIT) and there is a wide variety of algorithms based on several assumptions. With the Graz consensus reconstruction algorithm for EIT (GREIT), a novel linear reconstruction algorithm as well as a standardized framework for evaluating and comparing methods of reconstruction were introduced that found widespread acceptance in the community. In this paper, we propose a two-sided extension of this concept by first introducing a novel method of evaluation. Instead of being based on point-shaped resistivity distributions, we use 2759 pairs of real lung shapes for evaluation that were automatically segmented from human CT data. Necessarily, the figures of merit defined in GREIT were adjusted. Second, a linear method of reconstruction that uses orthonormal eigenimages as training data and a tunable desired point spread function are proposed. Using our novel method of evaluation, this approach is compared to the classical point-shaped approach. Results show that most figures of merit improve with the use of eigenimages as training data. Moreover, the possibility of tuning the reconstruction by modifying the desired point spread function is shown. Finally, the reconstruction of real EIT data shows that higher contrasts and fewer artifacts can be achieved in ventilation- and perfusion-related images.

  17. A shape-based quality evaluation and reconstruction method for electrical impedance tomography

    International Nuclear Information System (INIS)

    Antink, Christoph Hoog; Pikkemaat, Robert; Leonhardt, Steffen; Malmivuo, Jaakko

    2015-01-01

    Linear methods of reconstruction play an important role in medical electrical impedance tomography (EIT) and there is a wide variety of algorithms based on several assumptions. With the Graz consensus reconstruction algorithm for EIT (GREIT), a novel linear reconstruction algorithm as well as a standardized framework for evaluating and comparing methods of reconstruction were introduced that found widespread acceptance in the community.In this paper, we propose a two-sided extension of this concept by first introducing a novel method of evaluation. Instead of being based on point-shaped resistivity distributions, we use 2759 pairs of real lung shapes for evaluation that were automatically segmented from human CT data. Necessarily, the figures of merit defined in GREIT were adjusted. Second, a linear method of reconstruction that uses orthonormal eigenimages as training data and a tunable desired point spread function are proposed.Using our novel method of evaluation, this approach is compared to the classical point-shaped approach. Results show that most figures of merit improve with the use of eigenimages as training data. Moreover, the possibility of tuning the reconstruction by modifying the desired point spread function is shown. Finally, the reconstruction of real EIT data shows that higher contrasts and fewer artifacts can be achieved in ventilation- and perfusion-related images. (paper)

  18. STAR reconstruction improvements for tracking with the heavy flavor tracker

    Science.gov (United States)

    Webb, Jason C.; Lauret, Jérôme; Perevotchikov, Victor; Smirnov, Dmitri; Van Buren, Gene

    2017-10-01

    The reconstruction and identification of charmed hadron decays provides an important tool for the study of heavy quark behavior in the Quark Gluon Plasma. Such measurements require high resolution to topologically identify decay daughters at vertices displaced demands on track reconstruction software. To enable these measurements at RHIC, the STAR experiment has designed and employed the Heavy Flavor Tracker (HFT). It is composed of silicon-based tracking detectors, providing four layers of high-precision position measurements which are used in combination with hits from the Time Projection Chamber (TPC) to reconstruct track candidates. The STAR integrated tracking software (Sti) has delivered a decade of world-class physics. It was designed to leverage the discrete azimuthal symmetry of the detector and its simple radial ordering of components, permitting a flat representation of the detector geometry in terms of concentric cylinders and planes, and an approximate track propagation code. These design choices reflected a careful balancing of competing priorities, trading precision for speed in track reconstruction. To simplify the task of integrating new detectors, tools were developed to automatically generate the Sti geometry model, tying both reconstruction and simulation to the single source AgML geometry model. The increased precision and complexity of the HFT detector required a careful reassessment of this single geometry path and implementation choices. In this paper we will discuss the test suite and regression tools developed to improve reconstruction with the HFT, our lessons learned in tracking with high precision detectors and the tradeoffs between precision, speed and ease of use which were required.

  19. Optimizing the reconstruction filter in cone-beam CT to improve periodontal ligament space visualization: An in vitro study

    International Nuclear Information System (INIS)

    Houno, Yuuki; Kodera, Yoshie; Hishikawa, Toshimitsu; Naitoh, Munetaka; Mitani, Akio; Noguchi, Toshihide; Ariji, Eiichiro; Gotoh, Kenichi

    2017-01-01

    Evaluation of alveolar bone is important in the diagnosis of dental diseases. The periodontal ligament space is difficult to clearly depict in cone-beam computed tomography images because the reconstruction filter conditions during image processing cause image blurring, resulting in decreased spatial resolution. We examined different reconstruction filters to assess their ability to improve spatial resolution and allow for a clearer visualization of the periodontal ligament space. Cone-beam computed tomography projections of 2 skull phantoms were reconstructed using 6 reconstruction conditions and then compared using the Thurstone paired comparison method. Physical evaluations, including the modulation transfer function and the Wiener spectrum, as well as an assessment of space visibility, were undertaken using experimental phantoms. Image reconstruction using a modified Shepp-Logan filter resulted in better sensory, physical, and quantitative evaluations. The reconstruction conditions substantially improved the spatial resolution and visualization of the periodontal ligament space. The difference in sensitivity was obtained by altering the reconstruction filter. Modifying the characteristics of a reconstruction filter can generate significant improvement in assessments of the periodontal ligament space. A high-frequency enhancement filter improves the visualization of thin structures and will be useful when accurate assessment of the periodontal ligament space is necessary

  20. Optimizing the reconstruction filter in cone-beam CT to improve periodontal ligament space visualization: An in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Houno, Yuuki; Kodera, Yoshie [Graduate School of Medicine, Nagoya University, Nagoya (Japan); Hishikawa, Toshimitsu; Naitoh, Munetaka; Mitani, Akio; Noguchi, Toshihide; Ariji, Eiichiro [Aichi Gakuin University, Nisshin (Japan); Gotoh, Kenichi [Div. of Radiology, Dental Hospital, Aichi Gakuin University, Nisshin (Japan)

    2017-09-15

    Evaluation of alveolar bone is important in the diagnosis of dental diseases. The periodontal ligament space is difficult to clearly depict in cone-beam computed tomography images because the reconstruction filter conditions during image processing cause image blurring, resulting in decreased spatial resolution. We examined different reconstruction filters to assess their ability to improve spatial resolution and allow for a clearer visualization of the periodontal ligament space. Cone-beam computed tomography projections of 2 skull phantoms were reconstructed using 6 reconstruction conditions and then compared using the Thurstone paired comparison method. Physical evaluations, including the modulation transfer function and the Wiener spectrum, as well as an assessment of space visibility, were undertaken using experimental phantoms. Image reconstruction using a modified Shepp-Logan filter resulted in better sensory, physical, and quantitative evaluations. The reconstruction conditions substantially improved the spatial resolution and visualization of the periodontal ligament space. The difference in sensitivity was obtained by altering the reconstruction filter. Modifying the characteristics of a reconstruction filter can generate significant improvement in assessments of the periodontal ligament space. A high-frequency enhancement filter improves the visualization of thin structures and will be useful when accurate assessment of the periodontal ligament space is necessary.

  1. Algebraic 2D PET image reconstruction using depth-of-interaction information

    International Nuclear Information System (INIS)

    Yamaya, Taiga; Obi, Takashi; Yamaguchi, Masahiro; Kita, Kouichi

    2001-01-01

    Recently a high-performance PET scanner, which measures depth-of-interaction (DOI) information, is being developed for molecular imaging. DOI measurement of multi-layered thin crystals can improve spatial resolution and scanner sensitivity simultaneously. In this paper, we apply an algebraic image reconstruction method to 2-dimensional (2D) DOI-PET scanners using accurate system modeling, in order to evaluate the effects of using DOI information on PET image quality. Algebraic image reconstruction methods have been successfully used to improve PET image quality, compared with the conventional filtered backprojection method. The proposed method is applied to simulated data for a small 2D DOI-PET scanner. The results show that accurate system modeling improves spatial resolution without noise emphasis, and that DOI information improves uniformity of spatial resolution. (author)

  2. Does quality improvement work in neonatology improve clinical outcomes?

    Science.gov (United States)

    Ellsbury, Dan L; Clark, Reese H

    2017-04-01

    Quality improvement initiatives in neonatology have been promoted as an important way of improving outcomes of newborns. The purpose of this review is to examine the effectiveness of recent quality improvement work in improving the outcomes of infants requiring neonatal intensive care. Quality improvement collaboratives and single-center projects demonstrate improvement of clinical processes and outcomes in neonatology that impact both preterm and term infants. Declines in morbidities, resource use, and length of stay have been associated with reductions in healthcare costs. Recent quality improvement work has shown evidence of improvement in clinical outcomes in neonatal intensive care patients. These improvements have important implications for the reduction of healthcare costs in this population.

  3. 256-Slice coronary computed tomographic angiography in patients with atrial fibrillation: optimal reconstruction phase and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Oda, Seitaro; Yuki, Hideaki; Kidoh, Masafumi; Utsunomiya, Daisuke; Nakaura, Takeshi; Namimoto, Tomohiro; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Faculty of Life Sciences, Chuou-ku, Kumamoto (Japan); Honda, Keiichi; Yoshimura, Akira; Katahira, Kazuhiro [Kumamoto Chuo Hospital, Department of Diagnostic Radiology, Minami-ku, Kumamoto (Japan); Noda, Katsuo; Oshima, Shuichi [Kumamoto Chuo Hospital, Department of Cardiology, Minami-ku, Kumamoto (Japan)

    2016-01-15

    To assess the optimal reconstruction phase and the image quality of coronary computed tomographic angiography (CCTA) in patients with atrial fibrillation (AF). We performed CCTA in 60 patients with AF and 60 controls with sinus rhythm. The images were reconstructed in multiple phases in all parts of the cardiac cycle, and the optimal reconstruction phase with the fewest motion artefacts was identified. The coronary artery segments were visually evaluated to investigate their assessability. In 46 (76.7 %) patients, the optimal reconstruction phase was end-diastole, whereas in 6 (10.0 %) patients it was end-systole or mid-diastole, and in 2 (3.3 %) patients it was another cardiac phase. In 53 (88.3 %) of the controls, the optimal reconstruction phase was mid-diastole, whereas it was end-systole in 4 (6.7 %), and in 3 (5.0 %) it was another cardiac phase. There was a significant difference between patients with AF and the controls in the optimal phase (p < 0.01) but not in the visual image quality score (p = 0.06). The optimal reconstruction phase in most patients with AF was the end-diastolic phase. The end-systolic phase tended to be optimal in AF patients with higher average heart rates. (orig.)

  4. Quality improvement: the nurse's role.

    Science.gov (United States)

    Moran, M J; Johnson, J E

    1992-06-01

    Continuous quality improvement is a concept which includes: Quality assurance--the provision of services that meet an appropriate standard. Problem resolution--including all departments involved in the issue at hand. Quality improvement--a continuous process involving all levels of the organization working together across departmental lines to produce better services for health care clients. Deming (1982b) and others have espoused total system reform to achieve quality improvement--not merely altering the current system, but radically changing it. It must be assumed that those who provide services at the staff level are acting in good faith and are not willfully failing to do what is correct (Berwick, 1991). Those who perform direct services are in an excellent position to identify the need for change in service delivery processes. Based on this premise, the staff nurse--who is at the heart of the system--is the best person to assess the status of health care services and to work toward improving the processes by which these services are provided to clients in the health care setting. The nurse manager must structure the work setting to facilitate the staff nurse's ability to undertake constructive action for improving care. The use of quality circles, quality councils, or quality improvement forums to facilitate the coordination of quality improvement efforts is an effective way to achieve success. The QA coordinator assists departments in documenting that the quality improvement efforts are effective across all departments of the organization, and aggregates data to demonstrate that they meet the requirements of external regulatory agencies, insurers, and professional standards. The nurse executive provides the vision and secures the necessary resources to ensure that the organization's quality improvement efforts are successful. By inspiring and empowering the staff in their efforts to improve the process by which health care is provided, nurse managers

  5. Aesthetic outcome, patient satisfaction, and health-related quality of life in women at high risk undergoing prophylactic mastectomy and immediate breast reconstruction.

    Science.gov (United States)

    Isern, A E; Tengrup, I; Loman, N; Olsson, H; Ringberg, A

    2008-10-01

    Prophylactic mastectomy is an effective risk-reducing option in women with hereditary increased risk of breast cancer. It may be combined with immediate reconstruction, with the intention of improving aesthetic outcome and health-related quality of life. Sixty-one women underwent prophylactic mastectomy and immediate breast reconstruction in Malmö, Sweden, between 1995 and 2003. Forty women underwent bilateral prophylactic mastectomy and immediate reconstruction. Ten of these had a previous breast cancer diagnosis. Twenty-one women underwent contralateral prophylactic mastectomy and immediate reconstruction after a previous breast cancer. Fifty-four of the women (89%) were evaluated clinically for aesthetic results and complications. Patient satisfaction and quality of life were evaluated with one study-specific and two standardised health-related questionnaires administered at time of clinical follow-up. Median follow-up time was 42 months (range 7-99 months). The position of the reconstructed breasts was judged as satisfactory in 77% of breasts. Symmetry in relation to the midline was adequate in 89% of breasts. A capsular contracture grade III according to Baker and indentation tonometry was observed in 1% of breasts (1/104). The complication rate was 18% (7% early and 11% late). Secondary corrections were carried out in 11% of breasts. The study-specific questionnaire revealed a high degree of satisfaction. No woman regretted the procedure, and all women would have chosen the same type of surgery again. An age-stratified comparison of Swedish women using the Short Form 36 Health Survey Questionnaire (SF-36) questionnaire was carried out for this study. The study population scores were high, suggesting that prophylactic mastectomy and immediate reconstruction on both physical and psychological issues in this retrospective study had no negative effect. Also, the Hospital Anxiety and Depression Scale (HAD) questionnaire did not suggest any increased anxiety or

  6. The use of anatomical information for molecular image reconstruction algorithms: Attention/Scatter correction, motion compensation, and noise reduction

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Se Young [School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan (Korea, Republic of)

    2016-03-15

    PET and SPECT are important tools for providing valuable molecular information about patients to clinicians. Advances in nuclear medicine hardware technologies and statistical image reconstruction algorithms enabled significantly improved image quality. Sequentially or simultaneously acquired anatomical images such as CT and MRI from hybrid scanners are also important ingredients for improving the image quality of PET or SPECT further. High-quality anatomical information has been used and investigated for attenuation and scatter corrections, motion compensation, and noise reduction via post-reconstruction filtering and regularization in inverse problems. In this article, we will review works using anatomical information for molecular image reconstruction algorithms for better image quality by describing mathematical models, discussing sources of anatomical information for different cases, and showing some examples.

  7. Reconstructions with identical filling (RIF) of the heart: a physiological approach to image reconstruction in coronary CT angiography

    International Nuclear Information System (INIS)

    Reinartz, S.D.; Diefenbach, B.S.; Kuhl, C.K.; Mahnken, A.H.; Allmendinger, T.

    2012-01-01

    To compare image quality in coronary artery computed tomography angiography (cCTA) using reconstructions with automated phase detection and Reconstructions computed with Identical Filling of the heart (RIF). Seventy-four patients underwent ECG-gated dual source CT (DSCT) between November 2009 and July 2010 for suspected coronary heart disease (n = 35), planning of transcatheter aortic valve replacement (n = 34) or evaluation of ventricular function (n = 5). Image data sets by the RIF formula and automated phase detection were computed and evaluated with the AHA 15-segment model and a 5-grade Likert scale (1: poor, 5: excellent quality). Subgroups regarding rhythm (sinus rhythm = SR; arrhythmia = ARR) and potential premedication were evaluated by a per-segment, per-vessel and per-patient analysis. RIF significantly improved image quality in 10 of 15 coronary segments (P < 0.05). More diagnostic segments were provided by RIF regarding the entire cohort (n = 693 vs. 590, P < 0.001) and all of the subgroups (e.g. ARR: n = 143 vs. 72, P < 0.001). In arrhythmic patients (n = 19), more diagnostic vessels (e.g. LAD: n = 10 vs. 3; P < 0.014) and complete data sets (n = 7 vs. 1; P < 0.001) were produced. RIF reconstruction is superior to automatic diastolic non-edited reconstructions, especially in arrhythmic patients. RIF theory provides a physiological approach for determining the optimal image reconstruction point in ECG-gated CT angiography. (orig.)

  8. Iterative Reconstruction Techniques in Abdominopelvic CT: Technical Concepts and Clinical Implementation.

    Science.gov (United States)

    Patino, Manuel; Fuentes, Jorge M; Singh, Sarabjeet; Hahn, Peter F; Sahani, Dushyant V

    2015-07-01

    This article discusses the clinical challenge of low-radiation-dose examinations, the commonly used approaches for dose optimization, and their effect on image quality. We emphasize practical aspects of the different iterative reconstruction techniques, along with their benefits, pitfalls, and clinical implementation. The widespread use of CT has raised concerns about potential radiation risks, motivating diverse strategies to reduce the radiation dose associated with CT. CT manufacturers have developed alternative reconstruction algorithms intended to improve image quality on dose-optimized CT studies, mainly through noise and artifact reduction. Iterative reconstruction techniques take unique approaches to noise reduction and provide distinct strength levels or settings.

  9. Using Lean to Advance Quality Improvement Research.

    Science.gov (United States)

    Blackmore, Christopher Craig; Williams, Barbara L; Ching, Joan M; Chafetz, Lynne A; Kaplan, Gary S

    2016-01-01

    Quality improvement research skills are not commonplace among quality improvement practitioners, and research on the effectiveness of quality improvement has not always kept pace with improvement innovation. However, the Lean tools applied to quality improvement should be equally relevant to the advancement of quality improvement research. We applied the Lean methods to develop a simplified quality improvement publication pathway enabling a small research methodology group to increase quality improvement research throughout the institution. The key innovations of the pathway are horizontal integration of the quality improvement research methods group across the institution, implementation of a Lean quality improvement research pathway, and application of a just-in-time quality improvement research toolkit. This work provides a road map and tools for the acceleration of quality improvement research. At our institution, the Lean quality improvement research approach was associated with statistically significant increases in the number (annual mean increase from 3.0 to 8.5, p = .03) and breadth of published quality improvement research articles, and in the number of quality improvement research projects currently in process. Application of Lean methods to the quality improvement research process can aid in increasing publication of quality improvement articles from across the institution.

  10. A low-count reconstruction algorithm for Compton-based prompt gamma imaging

    Science.gov (United States)

    Huang, Hsuan-Ming; Liu, Chih-Chieh; Jan, Meei-Ling; Lee, Ming-Wei

    2018-04-01

    The Compton camera is an imaging device which has been proposed to detect prompt gammas (PGs) produced by proton–nuclear interactions within tissue during proton beam irradiation. Compton-based PG imaging has been developed to verify proton ranges because PG rays, particularly characteristic ones, have strong correlations with the distribution of the proton dose. However, accurate image reconstruction from characteristic PGs is challenging because the detector efficiency and resolution are generally low. Our previous study showed that point spread functions can be incorporated into the reconstruction process to improve image resolution. In this study, we proposed a low-count reconstruction algorithm to improve the image quality of a characteristic PG emission by pooling information from other characteristic PG emissions. PGs were simulated from a proton beam irradiated on a water phantom, and a two-stage Compton camera was used for PG detection. The results show that the image quality of the reconstructed characteristic PG emission is improved with our proposed method in contrast to the standard reconstruction method using events from only one characteristic PG emission. For the 4.44 MeV PG rays, both methods can be used to predict the positions of the peak and the distal falloff with a mean accuracy of 2 mm. Moreover, only the proposed method can improve the estimated positions of the peak and the distal falloff of 5.25 MeV PG rays, and a mean accuracy of 2 mm can be reached.

  11. Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR)

    International Nuclear Information System (INIS)

    Shieh, Chun-Chien; Kipritidis, John; O'Brien, Ricky T; Cooper, Benjamin J; Keall, Paul J; Kuncic, Zdenka

    2015-01-01

    did not suffer from residual noise/streaking and motion blur migrated from the prior image as in PICCS. AAIR was also found to be more computationally efficient than both ASD-POCS and PICCS, with a reduction in computation time of over 50% compared to ASD-POCS. The use of anatomy segmentation was, for the first time, demonstrated to significantly improve image quality and computational efficiency for thoracic 4D CBCT reconstruction. Further developments are required to facilitate AAIR for practical use. (paper)

  12. Blind compressed sensing image reconstruction based on alternating direction method

    Science.gov (United States)

    Liu, Qinan; Guo, Shuxu

    2018-04-01

    In order to solve the problem of how to reconstruct the original image under the condition of unknown sparse basis, this paper proposes an image reconstruction method based on blind compressed sensing model. In this model, the image signal is regarded as the product of a sparse coefficient matrix and a dictionary matrix. Based on the existing blind compressed sensing theory, the optimal solution is solved by the alternative minimization method. The proposed method solves the problem that the sparse basis in compressed sensing is difficult to represent, which restrains the noise and improves the quality of reconstructed image. This method ensures that the blind compressed sensing theory has a unique solution and can recover the reconstructed original image signal from a complex environment with a stronger self-adaptability. The experimental results show that the image reconstruction algorithm based on blind compressed sensing proposed in this paper can recover high quality image signals under the condition of under-sampling.

  13. MRI reconstruction of multi-image acquisitions using a rank regularizer with data reordering

    Energy Technology Data Exchange (ETDEWEB)

    Adluru, Ganesh, E-mail: gadluru@gmail.com; Anderson, Jeffrey [UCAIR, Department of Radiology, University of Utah, Salt Lake City, Utah 84108 (United States); Gur, Yaniv [IBM Almaden Research Center, San Jose, California 95120 (United States); Chen, Liyong; Feinberg, David [Advanced MRI Technologies, Sebastpool, California, 95472 (United States); DiBella, Edward V. R. [UCAIR, Department of Radiology, University of Utah, Salt Lake City, Utah 84108 and Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112 (United States)

    2015-08-15

    Purpose: To improve rank constrained reconstructions for undersampled multi-image MRI acquisitions. Methods: Motivated by the recent developments in low-rank matrix completion theory and its applicability to rapid dynamic MRI, a new reordering-based rank constrained reconstruction of undersampled multi-image data that uses prior image information is proposed. Instead of directly minimizing the nuclear norm of a matrix of estimated images, the nuclear norm of reordered matrix values is minimized. The reordering is based on the prior image estimates. The method is tested on brain diffusion imaging data and dynamic contrast enhanced myocardial perfusion data. Results: Good quality images from data undersampled by a factor of three for diffusion imaging and by a factor of 3.5 for dynamic cardiac perfusion imaging with respiratory motion were obtained. Reordering gave visually improved image quality over standard nuclear norm minimization reconstructions. Root mean squared errors with respect to ground truth images were improved by ∼18% and ∼16% with reordering for diffusion and perfusion applications, respectively. Conclusions: The reordered low-rank constraint is a way to inject prior image information that offers improvements over a standard low-rank constraint for undersampled multi-image MRI reconstructions.

  14. MRI reconstruction of multi-image acquisitions using a rank regularizer with data reordering

    International Nuclear Information System (INIS)

    Adluru, Ganesh; Anderson, Jeffrey; Gur, Yaniv; Chen, Liyong; Feinberg, David; DiBella, Edward V. R.

    2015-01-01

    Purpose: To improve rank constrained reconstructions for undersampled multi-image MRI acquisitions. Methods: Motivated by the recent developments in low-rank matrix completion theory and its applicability to rapid dynamic MRI, a new reordering-based rank constrained reconstruction of undersampled multi-image data that uses prior image information is proposed. Instead of directly minimizing the nuclear norm of a matrix of estimated images, the nuclear norm of reordered matrix values is minimized. The reordering is based on the prior image estimates. The method is tested on brain diffusion imaging data and dynamic contrast enhanced myocardial perfusion data. Results: Good quality images from data undersampled by a factor of three for diffusion imaging and by a factor of 3.5 for dynamic cardiac perfusion imaging with respiratory motion were obtained. Reordering gave visually improved image quality over standard nuclear norm minimization reconstructions. Root mean squared errors with respect to ground truth images were improved by ∼18% and ∼16% with reordering for diffusion and perfusion applications, respectively. Conclusions: The reordered low-rank constraint is a way to inject prior image information that offers improvements over a standard low-rank constraint for undersampled multi-image MRI reconstructions

  15. Improved compressed sensing-based cone-beam CT reconstruction using adaptive prior image constraints

    Science.gov (United States)

    Lee, Ho; Xing, Lei; Davidi, Ran; Li, Ruijiang; Qian, Jianguo; Lee, Rena

    2012-04-01

    Volumetric cone-beam CT (CBCT) images are acquired repeatedly during a course of radiation therapy and a natural question to ask is whether CBCT images obtained earlier in the process can be utilized as prior knowledge to reduce patient imaging dose in subsequent scans. The purpose of this work is to develop an adaptive prior image constrained compressed sensing (APICCS) method to solve this problem. Reconstructed images using full projections are taken on the first day of radiation therapy treatment and are used as prior images. The subsequent scans are acquired using a protocol of sparse projections. In the proposed APICCS algorithm, the prior images are utilized as an initial guess and are incorporated into the objective function in the compressed sensing (CS)-based iterative reconstruction process. Furthermore, the prior information is employed to detect any possible mismatched regions between the prior and current images for improved reconstruction. For this purpose, the prior images and the reconstructed images are classified into three anatomical regions: air, soft tissue and bone. Mismatched regions are identified by local differences of the corresponding groups in the two classified sets of images. A distance transformation is then introduced to convert the information into an adaptive voxel-dependent relaxation map. In constructing the relaxation map, the matched regions (unchanged anatomy) between the prior and current images are assigned with smaller weight values, which are translated into less influence on the CS iterative reconstruction process. On the other hand, the mismatched regions (changed anatomy) are associated with larger values and the regions are updated more by the new projection data, thus avoiding any possible adverse effects of prior images. The APICCS approach was systematically assessed by using patient data acquired under standard and low-dose protocols for qualitative and quantitative comparisons. The APICCS method provides an

  16. Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Gi [Ajou University School of Medicine, Ajou University Medical Center, Department of Radiology, Yeongtong-gu, Suwon (Korea, Republic of); Lee, Ho-Joon; Lee, Seung-Koo; Kim, Myung-Joon [Severance Hospital, Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Seodaemun-gu, Seoul (Korea, Republic of); Kim, Hyun Ji [Ajou University School of Medicine, Office of Biostatistics, Department of Humanities and Social Medicine, Yeongtong-gu, Suwon (Korea, Republic of)

    2017-09-15

    To investigate the quality of images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V), using pediatric head CT protocols. A phantom was scanned at decreasing 20% mA intervals using our standard pediatric head CT protocols. Each study was then reconstructed at 10% ASIR-V intervals. After the phantom study, we reduced mA by 10% in the protocol for <3-year-old patients and applied 30% ASIR-V and by 30% in the protocol for 3- to 15-year-old patients and applied 40% ASIR-V. Increasing the percentage of ASIR-V resulted in lower noise and higher contrast-to-noise ratio (CNR) and preserved spatial resolution in the phantom study. Compared to a conventional-protocol, reduced-dose protocol with ASIR-V achieved 12.8% to 34.0% of dose reduction and showed images of lower noise (9.22 vs. 10.73, P = 0.043) and higher CNR in different levels (centrum semiovale, 2.14 vs. 1.52, P = 0.003; basal ganglia, 1.46 vs. 1.07, P = 0.001; and cerebellum, 2.18 vs. 1.33, P < 0.001). Qualitative analysis showed higher gray-white matter differentiation and sharpness and preserved overall diagnostic quality in the images with ASIR-V. Use of ASIR-V allowed a 12.8% to 34.0% dose reduction in each age group with potential to improve image quality. (orig.)

  17. Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children

    International Nuclear Information System (INIS)

    Kim, Hyun Gi; Lee, Ho-Joon; Lee, Seung-Koo; Kim, Myung-Joon; Kim, Hyun Ji

    2017-01-01

    To investigate the quality of images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V), using pediatric head CT protocols. A phantom was scanned at decreasing 20% mA intervals using our standard pediatric head CT protocols. Each study was then reconstructed at 10% ASIR-V intervals. After the phantom study, we reduced mA by 10% in the protocol for <3-year-old patients and applied 30% ASIR-V and by 30% in the protocol for 3- to 15-year-old patients and applied 40% ASIR-V. Increasing the percentage of ASIR-V resulted in lower noise and higher contrast-to-noise ratio (CNR) and preserved spatial resolution in the phantom study. Compared to a conventional-protocol, reduced-dose protocol with ASIR-V achieved 12.8% to 34.0% of dose reduction and showed images of lower noise (9.22 vs. 10.73, P = 0.043) and higher CNR in different levels (centrum semiovale, 2.14 vs. 1.52, P = 0.003; basal ganglia, 1.46 vs. 1.07, P = 0.001; and cerebellum, 2.18 vs. 1.33, P < 0.001). Qualitative analysis showed higher gray-white matter differentiation and sharpness and preserved overall diagnostic quality in the images with ASIR-V. Use of ASIR-V allowed a 12.8% to 34.0% dose reduction in each age group with potential to improve image quality. (orig.)

  18. Accelerate Water Quality Improvement

    Science.gov (United States)

    EPA is committed to accelerating water quality improvement and minimizing negative impacts to aquatic life from contaminants and other stressors in the Bay Delta Estuary by working with California Water Boards to strengthen water quality improvement plans.

  19. Clinical evaluation of image quality and radiation dose reduction in upper abdominal computed tomography using model-based iterative reconstruction; comparison with filtered back projection and adaptive statistical iterative reconstruction

    International Nuclear Information System (INIS)

    Nakamoto, Atsushi; Kim, Tonsok; Hori, Masatoshi; Onishi, Hiromitsu; Tsuboyama, Takahiro; Sakane, Makoto; Tatsumi, Mitsuaki; Tomiyama, Noriyuki

    2015-01-01

    Highlights: • MBIR significantly improves objective image quality. • MBIR reduces the radiation dose by 87.5% without increasing objective image noise. • A half dose will be needed to maintain the subjective image quality. - Abstract: Purpose: To evaluate the image quality of upper abdominal CT images reconstructed with model-based iterative reconstruction (MBIR) in comparison with filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) on scans acquired with various radiation exposure dose protocols. Materials and methods: This prospective study was approved by our institutional review board, and informed consent was obtained from all 90 patients who underwent both control-dose (CD) and reduced-dose (RD) CT of the upper abdomen (unenhanced: n = 45, contrast-enhanced: n = 45). The RD scan protocol was randomly selected from three protocols; Protocol A: 12.5% dose, Protocol B: 25% dose, Protocol C: 50% dose. Objective image noise, signal-to-noise (SNR) ratio for the liver parenchyma, visual image score and lesion conspicuity were compared among CD images of FBP and RD images of FBP, ASIR and MBIR. Results: RD images of MBIR yielded significantly lower objective image noise and higher SNR compared with RD images of FBP and ASIR for all protocols (P < .01) and CD images of FBP for Protocol C (P < .05). Although the subjective image quality of RD images of MBIR was almost acceptable for Protocol C, it was inferior to that of CD images of FBP for Protocols A and B (P < .0083). The conspicuity of the small lesions in RD images of MBIR tended to be superior to that in RD images of FBP and ASIR and inferior to that in CD images for Protocols A and B, although the differences were not significant (P > .0083). Conclusion: Although 12.5%-dose MBIR images (mean size-specific dose estimates [SSDE] of 1.13 mGy) yielded objective image noise and SNR comparable to CD-FBP images, at least a 50% dose (mean SSDE of 4.63 mGy) would be needed to

  20. Clinical evaluation of image quality and radiation dose reduction in upper abdominal computed tomography using model-based iterative reconstruction; comparison with filtered back projection and adaptive statistical iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Nakamoto, Atsushi, E-mail: a-nakamoto@radiol.med.osaka-u.ac.jp; Kim, Tonsok, E-mail: kim@radiol.med.osaka-u.ac.jp; Hori, Masatoshi, E-mail: mhori@radiol.med.osaka-u.ac.jp; Onishi, Hiromitsu, E-mail: h-onishi@radiol.med.osaka-u.ac.jp; Tsuboyama, Takahiro, E-mail: t-tsuboyama@radiol.med.osaka-u.ac.jp; Sakane, Makoto, E-mail: m-sakane@radiol.med.osaka-u.ac.jp; Tatsumi, Mitsuaki, E-mail: m-tatsumi@radiol.med.osaka-u.ac.jp; Tomiyama, Noriyuki, E-mail: tomiyama@radiol.med.osaka-u.ac.jp

    2015-09-15

    Highlights: • MBIR significantly improves objective image quality. • MBIR reduces the radiation dose by 87.5% without increasing objective image noise. • A half dose will be needed to maintain the subjective image quality. - Abstract: Purpose: To evaluate the image quality of upper abdominal CT images reconstructed with model-based iterative reconstruction (MBIR) in comparison with filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) on scans acquired with various radiation exposure dose protocols. Materials and methods: This prospective study was approved by our institutional review board, and informed consent was obtained from all 90 patients who underwent both control-dose (CD) and reduced-dose (RD) CT of the upper abdomen (unenhanced: n = 45, contrast-enhanced: n = 45). The RD scan protocol was randomly selected from three protocols; Protocol A: 12.5% dose, Protocol B: 25% dose, Protocol C: 50% dose. Objective image noise, signal-to-noise (SNR) ratio for the liver parenchyma, visual image score and lesion conspicuity were compared among CD images of FBP and RD images of FBP, ASIR and MBIR. Results: RD images of MBIR yielded significantly lower objective image noise and higher SNR compared with RD images of FBP and ASIR for all protocols (P < .01) and CD images of FBP for Protocol C (P < .05). Although the subjective image quality of RD images of MBIR was almost acceptable for Protocol C, it was inferior to that of CD images of FBP for Protocols A and B (P < .0083). The conspicuity of the small lesions in RD images of MBIR tended to be superior to that in RD images of FBP and ASIR and inferior to that in CD images for Protocols A and B, although the differences were not significant (P > .0083). Conclusion: Although 12.5%-dose MBIR images (mean size-specific dose estimates [SSDE] of 1.13 mGy) yielded objective image noise and SNR comparable to CD-FBP images, at least a 50% dose (mean SSDE of 4.63 mGy) would be needed to

  1. Spectral reconstruction for a 6 MV linear accelerator

    International Nuclear Information System (INIS)

    Hernandez-Bojorquez, M.; Martinez-Davalos, A.; Larraga, J. M.

    2004-01-01

    In this work we present the first results of an x-ray spectral reconstruction for a 6 MV Varian LINAC. The shape of the spectrum will be used in Monte Carlo treatment planning in order to improve the quality and accuracy of the calculated dose distributions. We based our simulation method on the formalism proposed by Francois et al. In this method the spectrum is reconstructed from transmission measurements under narrow beam geometry for multiple attenuator thicknesses. These data allowed us to reconstruct the x-ray spectrum through direct solution of matrix systems using spectral algebra formalism

  2. "Rheum to Improve": Quality Improvement in Outpatient Rheumatology.

    Science.gov (United States)

    Chow, Shirley L; Shojania, Kaveh G

    2017-09-01

    The commitment to improve care processes and patient outcomes is a professional mandate for clinicians and is also seen as an operational priority for institutions. Quality improvement now figures in the accreditation of training programs, specialty examinations, and hospital scorecards. Rheumatologists have traditionally focused primarily on quality problems such as guideline adherence; however, improvement goals should also include other aspects of care that are helpful to patients and are professionally rewarding for practitioners. This review makes use of improvement projects in outlining tangible tools rheumatologists can use to resolve quality concerns in their practices.

  3. A fast sparse reconstruction algorithm for electrical tomography

    International Nuclear Information System (INIS)

    Zhao, Jia; Xu, Yanbin; Tan, Chao; Dong, Feng

    2014-01-01

    Electrical tomography (ET) has been widely investigated due to its advantages of being non-radiative, low-cost and high-speed. However, the image reconstruction of ET is a nonlinear and ill-posed inverse problem and the imaging results are easily affected by measurement noise. A sparse reconstruction algorithm based on L 1 regularization is robust to noise and consequently provides a high quality of reconstructed images. In this paper, a sparse reconstruction by separable approximation algorithm (SpaRSA) is extended to solve the ET inverse problem. The algorithm is competitive with the fastest state-of-the-art algorithms in solving the standard L 2 −L 1 problem. However, it is computationally expensive when the dimension of the matrix is large. To further improve the calculation speed of solving inverse problems, a projection method based on the Krylov subspace is employed and combined with the SpaRSA algorithm. The proposed algorithm is tested with image reconstruction of electrical resistance tomography (ERT). Both simulation and experimental results demonstrate that the proposed method can reduce the computational time and improve the noise robustness for the image reconstruction. (paper)

  4. Comparison of different reconstruction algorithms for three-dimensional ultrasound imaging in a neurosurgical setting.

    Science.gov (United States)

    Miller, D; Lippert, C; Vollmer, F; Bozinov, O; Benes, L; Schulte, D M; Sure, U

    2012-09-01

    Freehand three-dimensional ultrasound imaging (3D-US) is increasingly used in image-guided surgery. During image acquisition, a set of B-scans is acquired that is distributed in a non-parallel manner over the area of interest. Reconstructing these images into a regular array allows 3D visualization. However, the reconstruction process may introduce artefacts and may therefore reduce image quality. The aim of the study is to compare different algorithms with respect to image quality and diagnostic value for image guidance in neurosurgery. 3D-US data sets were acquired during surgery of various intracerebral lesions using an integrated ultrasound-navigation device. They were stored for post-hoc evaluation. Five different reconstruction algorithms, a standard multiplanar reconstruction with interpolation (MPR), a pixel nearest neighbour method (PNN), a voxel nearest neighbour method (VNN) and two voxel based distance-weighted algorithms (VNN2 and DW) were tested with respect to image quality and artefact formation. The capability of the algorithm to fill gaps within the sample volume was investigated and a clinical evaluation with respect to the diagnostic value of the reconstructed images was performed. MPR was significantly worse than the other algorithms in filling gaps. In an image subtraction test, VNN2 and DW reliably reconstructed images even if large amounts of data were missing. However, the quality of the reconstruction improved, if data acquisition was performed in a structured manner. When evaluating the diagnostic value of reconstructed axial, sagittal and coronal views, VNN2 and DW were judged to be significantly better than MPR and VNN. VNN2 and DW could be identified as robust algorithms that generate reconstructed US images with a high diagnostic value. These algorithms improve the utility and reliability of 3D-US imaging during intraoperative navigation. Copyright © 2012 John Wiley & Sons, Ltd.

  5. Pore REconstruction and Segmentation (PORES) method for improved porosity quantification of nanoporous materials

    Energy Technology Data Exchange (ETDEWEB)

    Van Eyndhoven, G., E-mail: geert.vaneyndhoven@uantwerpen.be [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Kurttepeli, M. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Van Oers, C.J.; Cool, P. [Laboratory of Adsorption and Catalysis, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Bals, S. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Batenburg, K.J. [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Centrum Wiskunde and Informatica, Science Park 123, NL-1090 GB Amsterdam (Netherlands); Mathematical Institute, Universiteit Leiden, Niels Bohrweg 1, NL-2333 CA Leiden (Netherlands); Sijbers, J. [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium)

    2015-01-15

    Electron tomography is currently a versatile tool to investigate the connection between the structure and properties of nanomaterials. However, a quantitative interpretation of electron tomography results is still far from straightforward. Especially accurate quantification of pore-space is hampered by artifacts introduced in all steps of the processing chain, i.e., acquisition, reconstruction, segmentation and quantification. Furthermore, most common approaches require subjective manual user input. In this paper, the PORES algorithm “POre REconstruction and Segmentation” is introduced; it is a tailor-made, integral approach, for the reconstruction, segmentation, and quantification of porous nanomaterials. The PORES processing chain starts by calculating a reconstruction with a nanoporous-specific reconstruction algorithm: the Simultaneous Update of Pore Pixels by iterative REconstruction and Simple Segmentation algorithm (SUPPRESS). It classifies the interior region to the pores during reconstruction, while reconstructing the remaining region by reducing the error with respect to the acquired electron microscopy data. The SUPPRESS reconstruction can be directly plugged into the remaining processing chain of the PORES algorithm, resulting in accurate individual pore quantification and full sample pore statistics. The proposed approach was extensively validated on both simulated and experimental data, indicating its ability to generate accurate statistics of nanoporous materials. - Highlights: • An electron tomography reconstruction/segmentation method for nanoporous materials. • The method exploits the porous nature of the scanned material. • Validated extensively on both simulation and real data experiments. • Results in increased image resolution and improved porosity quantification.

  6. Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT.

    Science.gov (United States)

    Matenine, Dmitri; Mascolo-Fortin, Julia; Goussard, Yves; Després, Philippe

    2015-11-01

    The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numerical simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can potentially improve the rendering of

  7. Effect of hybrid iterative reconstruction technique on quantitative and qualitative image analysis at 256-slice prospective gating cardiac CT

    International Nuclear Information System (INIS)

    Utsunomiya, Daisuke; Weigold, W. Guy; Weissman, Gaby; Taylor, Allen J.

    2012-01-01

    To evaluate the effect of hybrid iterative reconstruction on qualitative and quantitative parameters at 256-slice cardiac CT. Prospective cardiac CT images from 20 patients were analysed. Paired image sets were created using 3 reconstructions, i.e. filtered back projection (FBP) and moderate- and high-level iterative reconstructions. Quantitative parameters including CT-attenuation, noise, and contrast-to-noise ratio (CNR) were determined in both proximal- and distal coronary segments. Image quality was graded on a 4-point scale. Coronary CT attenuation values were similar for FBP, moderate- and high-level iterative reconstruction at 293 ± 74-, 290 ± 75-, and 283 ± 78 Hounsfield units (HU), respectively. CNR was significantly higher with moderate- and high-level iterative reconstructions (10.9 ± 3.5 and 18.4 ± 6.2, respectively) than FBP (8.2 ± 2.5) as was the visual grading of proximal vessels. Visualisation of distal vessels was better with high-level iterative reconstruction than FBP. The mean number of assessable segments among 289 segments was 245, 260, and 267 for FBP, moderate- and high-level iterative reconstruction, respectively; the difference between FBP and high-level iterative reconstruction was significant. Interobserver agreement was significantly higher for moderate- and high-level iterative reconstruction than FBP. Cardiac CT using hybrid iterative reconstruction yields higher CNR and better image quality than FBP. circle Cardiac CT helps clinicians to assess patients with coronary artery disease circle Hybrid iterative reconstruction provides improved cardiac CT image quality circle Hybrid iterative reconstruction improves the number of assessable coronary segments circle Hybrid iterative reconstruction improves interobserver agreement on cardiac CT. (orig.)

  8. A novel algorithm of super-resolution image reconstruction based on multi-class dictionaries for natural scene

    Science.gov (United States)

    Wu, Wei; Zhao, Dewei; Zhang, Huan

    2015-12-01

    Super-resolution image reconstruction is an effective method to improve the image quality. It has important research significance in the field of image processing. However, the choice of the dictionary directly affects the efficiency of image reconstruction. A sparse representation theory is introduced into the problem of the nearest neighbor selection. Based on the sparse representation of super-resolution image reconstruction method, a super-resolution image reconstruction algorithm based on multi-class dictionary is analyzed. This method avoids the redundancy problem of only training a hyper complete dictionary, and makes the sub-dictionary more representatives, and then replaces the traditional Euclidean distance computing method to improve the quality of the whole image reconstruction. In addition, the ill-posed problem is introduced into non-local self-similarity regularization. Experimental results show that the algorithm is much better results than state-of-the-art algorithm in terms of both PSNR and visual perception.

  9. Image quality of CT angiography in young children with congenital heart disease: a comparison between the sinogram-affirmed iterative reconstruction (SAFIRE) and advanced modelled iterative reconstruction (ADMIRE) algorithms.

    Science.gov (United States)

    Nam, S B; Jeong, D W; Choo, K S; Nam, K J; Hwang, J-Y; Lee, J W; Kim, J Y; Lim, S J

    2017-12-01

    To compare the image quality of computed tomography angiography (CTA) reconstructed by sinogram-affirmed iterative reconstruction (SAFIRE) with that of advanced modelled iterative reconstruction (ADMIRE) in children with congenital heart disease (CHD). Thirty-one children (8.23±13.92 months) with CHD who underwent CTA were enrolled. Images were reconstructed using SAFIRE (strength 5) and ADMIRE (strength 5). Objective image qualities (attenuation, noise) were measured in the great vessels and heart chambers. Two radiologists independently calculated the contrast-to-noise ratio (CNR) by measuring the intensity and noise of the myocardial walls. Subjective noise, diagnostic confidence, and sharpness at the level prior to the first branch of the main pulmonary artery were also graded by the two radiologists independently. The objective image noise of ADMIRE was significantly lower than that of SAFIRE in the right atrium, right ventricle, and myocardial wall (p0.05). The mean CNR values were 21.56±10.80 for ADMIRE and 18.21±6.98 for SAFIRE, which were significantly different (p0.05). CTA using ADMIRE was superior to SAFIRE when comparing the objective and subjective image quality in children with CHD. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  10. Function after oral oncological intervention, reconstruction and rehabilitation

    NARCIS (Netherlands)

    Speksnijder, C.M.

    2011-01-01

    In the Netherlands, the incidence of oral cancer is increasing. Progress in (reconstructive) surgery, radiotherapy and chemotherapy, however, has improved survival and loco-regional control while trying to preserve or restore oral function and quality of life. Despite the progress in treatment,

  11. Analysis of patient satisfaction and donor-site morbidity after different types of breast reconstruction

    NARCIS (Netherlands)

    Benditte-Klepetko, H. C.; Lutgendorff, F.; Kästenbauer, T.; Deutinger, M.; van der Horst, C. M. A. M.

    2014-01-01

    Breast reconstruction has been shown to improve quality of life. However, factors involved in long-term patient satisfaction are largely unknown. Our aim was to evaluate patient satisfaction and donor-site morbidity in five types of breast reconstruction. A prospectively collected database of all

  12. MO-G-17A-07: Improved Image Quality in Brain F-18 FDG PET Using Penalized-Likelihood Image Reconstruction Via a Generalized Preconditioned Alternating Projection Algorithm: The First Patient Results

    International Nuclear Information System (INIS)

    Schmidtlein, CR; Beattie, B; Humm, J; Li, S; Wu, Z; Xu, Y; Zhang, J; Shen, L; Vogelsang, L; Feiglin, D; Krol, A

    2014-01-01

    Purpose: To investigate the performance of a new penalized-likelihood PET image reconstruction algorithm using the 1 1 -norm total-variation (TV) sum of the 1st through 4th-order gradients as the penalty. Simulated and brain patient data sets were analyzed. Methods: This work represents an extension of the preconditioned alternating projection algorithm (PAPA) for emission-computed tomography. In this new generalized algorithm (GPAPA), the penalty term is expanded to allow multiple components, in this case the sum of the 1st to 4th order gradients, to reduce artificial piece-wise constant regions (“staircase” artifacts typical for TV) seen in PAPA images penalized with only the 1st order gradient. Simulated data were used to test for “staircase” artifacts and to optimize the penalty hyper-parameter in the root-mean-squared error (RMSE) sense. Patient FDG brain scans were acquired on a GE D690 PET/CT (370 MBq at 1-hour post-injection for 10 minutes) in time-of-flight mode and in all cases were reconstructed using resolution recovery projectors. GPAPA images were compared PAPA and RMSE-optimally filtered OSEM (fully converged) in simulations and to clinical OSEM reconstructions (3 iterations, 32 subsets) with 2.6 mm XYGaussian and standard 3-point axial smoothing post-filters. Results: The results from the simulated data show a significant reduction in the 'staircase' artifact for GPAPA compared to PAPA and lower RMSE (up to 35%) compared to optimally filtered OSEM. A simple power-law relationship between the RMSE-optimal hyper-parameters and the noise equivalent counts (NEC) per voxel is revealed. Qualitatively, the patient images appear much sharper and with less noise than standard clinical images. The convergence rate is similar to OSEM. Conclusions: GPAPA reconstructions using the 1 1 -norm total-variation sum of the 1st through 4th-order gradients as the penalty show great promise for the improvement of image quality over that currently

  13. MO-G-17A-07: Improved Image Quality in Brain F-18 FDG PET Using Penalized-Likelihood Image Reconstruction Via a Generalized Preconditioned Alternating Projection Algorithm: The First Patient Results

    Energy Technology Data Exchange (ETDEWEB)

    Schmidtlein, CR; Beattie, B; Humm, J [Memorial Sloan Kettering Cancer Center, New York, NY (United States); Li, S; Wu, Z; Xu, Y [Sun Yat-sen University, Guangzhou, Guangdong (China); Zhang, J; Shen, L [Syracuse University, Syracuse, NY (United States); Vogelsang, L [VirtualScopics, Rochester, NY (United States); Feiglin, D; Krol, A [SUNY Upstate Medical University, Syracuse, NY (United States)

    2014-06-15

    Purpose: To investigate the performance of a new penalized-likelihood PET image reconstruction algorithm using the 1{sub 1}-norm total-variation (TV) sum of the 1st through 4th-order gradients as the penalty. Simulated and brain patient data sets were analyzed. Methods: This work represents an extension of the preconditioned alternating projection algorithm (PAPA) for emission-computed tomography. In this new generalized algorithm (GPAPA), the penalty term is expanded to allow multiple components, in this case the sum of the 1st to 4th order gradients, to reduce artificial piece-wise constant regions (“staircase” artifacts typical for TV) seen in PAPA images penalized with only the 1st order gradient. Simulated data were used to test for “staircase” artifacts and to optimize the penalty hyper-parameter in the root-mean-squared error (RMSE) sense. Patient FDG brain scans were acquired on a GE D690 PET/CT (370 MBq at 1-hour post-injection for 10 minutes) in time-of-flight mode and in all cases were reconstructed using resolution recovery projectors. GPAPA images were compared PAPA and RMSE-optimally filtered OSEM (fully converged) in simulations and to clinical OSEM reconstructions (3 iterations, 32 subsets) with 2.6 mm XYGaussian and standard 3-point axial smoothing post-filters. Results: The results from the simulated data show a significant reduction in the 'staircase' artifact for GPAPA compared to PAPA and lower RMSE (up to 35%) compared to optimally filtered OSEM. A simple power-law relationship between the RMSE-optimal hyper-parameters and the noise equivalent counts (NEC) per voxel is revealed. Qualitatively, the patient images appear much sharper and with less noise than standard clinical images. The convergence rate is similar to OSEM. Conclusions: GPAPA reconstructions using the 1{sub 1}-norm total-variation sum of the 1st through 4th-order gradients as the penalty show great promise for the improvement of image quality over that

  14. Improved protein structure reconstruction using secondary structures, contacts at higher distance thresholds, and non-contacts.

    Science.gov (United States)

    Adhikari, Badri; Cheng, Jianlin

    2017-08-29

    Residue-residue contacts are key features for accurate de novo protein structure prediction. For the optimal utilization of these predicted contacts in folding proteins accurately, it is important to study the challenges of reconstructing protein structures using true contacts. Because contact-guided protein modeling approach is valuable for predicting the folds of proteins that do not have structural templates, it is necessary for reconstruction studies to focus on hard-to-predict protein structures. Using a data set consisting of 496 structural domains released in recent CASP experiments and a dataset of 150 representative protein structures, in this work, we discuss three techniques to improve the reconstruction accuracy using true contacts - adding secondary structures, increasing contact distance thresholds, and adding non-contacts. We find that reconstruction using secondary structures and contacts can deliver accuracy higher than using full contact maps. Similarly, we demonstrate that non-contacts can improve reconstruction accuracy not only when the used non-contacts are true but also when they are predicted. On the dataset consisting of 150 proteins, we find that by simply using low ranked predicted contacts as non-contacts and adding them as additional restraints, can increase the reconstruction accuracy by 5% when the reconstructed models are evaluated using TM-score. Our findings suggest that secondary structures are invaluable companions of contacts for accurate reconstruction. Confirming some earlier findings, we also find that larger distance thresholds are useful for folding many protein structures which cannot be folded using the standard definition of contacts. Our findings also suggest that for more accurate reconstruction using predicted contacts it is useful to predict contacts at higher distance thresholds (beyond 8 Å) and predict non-contacts.

  15. Colour-coded three-dimensional reconstruction from spiral CT data sets: Improvement from the physical point of view

    International Nuclear Information System (INIS)

    Wunderlich, A.P.; Lenz, M.; Kirsten, R.; Gerhardt, P.

    1993-01-01

    This paper demonstrates the possibility of improving the spatial depth impression of colour-coded three-dimensional reconstructions by modulation of colour saturation. Patients were observed with spiral computed tomography (slice thickness 10 mm, table feed 10 mm/s, reconstruction of overlapping axial images at 2 mm increment). Interesting anatomical and pathological objects (vessels, organs, tumours, metastases) were segmented, colour-coded, and reconstructed three-dimensionally. Spatial depth impression of the coloured objects could be improved by modulating not only the brightness, but also the colour saturation. (orig.) [de

  16. J-pouch versus Roux-en-Y reconstruction after gastrectomy: functional assessment and quality of life (randomized trial

    Directory of Open Access Journals (Sweden)

    Zonca P

    2016-12-01

    Full Text Available Pavel Zonča,1,2 Tomáš Malý,3 Peter Ihnát,1,2 Matus Peteja,1,2 Otakar Kraft,4 Kamil Kuca2,5 1Department of Surgery, University Hospital Ostrava, 2Department of Surgical Studies, Faculty of Medicine, University of Ostrava, Ostrava, 3Department of Surgery, University Hospital Olomouc, Olomouc, 4Department of Nuclear Medicine, University Hospital Ostrava, Ostrava, 5Biomedical Research Center, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic Purpose: The aim of this study was to evaluate the quality of life and functional emptying of J-pouch versus Roux-en-Y reconstruction after total gastrectomy for malignancy. Methods: This study was designed as a prospective, nonblinded, randomized, parallel clinical trial (Trial Number: MN Ostrava, 200604. With informed consent, patients undergoing gastrectomy for malignancy were randomized to J-pouch or Roux-en-Y reconstruction. The time taken for a test semisolid meal labeled with 99mTc-sulfur colloid to exit the reconstructed parts was measured by dynamic scintigraphy 1 year after resection. Quality of life was measured using the Eypasch questionnaire at the same time as functional emptying assessment. This trial was investigator-initiated. Results: In all, 72 patients were included into the study. The time taken for the test meal to exit the postgastrectomy reconstruction was 16.5±10.0 minutes (mean ± standard deviation in the Roux-en-Y group and 89.4±37.8 minutes in the “J-pouch” group; the difference was statistically significant (P<0.001. Emptying of the J-pouch appeared to be a linear decreasing function compared to the exponential pattern seen in the Roux-en-Y group. The quality of life measurement showed scores of 106±18.8 points (mean ± standard deviation in the Roux-en-Y group compared to 122±22.5 points in the J-pouch group; the difference was statistically significant (P=0.0016. There were no important adverse events. Conclusion: After total gastrectomy, a J

  17. Dosimetric quality assurance of highly conformal external beam treatments: from 2D phantom comparisons to 4D patient dose reconstruction

    International Nuclear Information System (INIS)

    Feygelman, V; Nelms, B

    2013-01-01

    As IMRT technology continues to evolve, so do the dosimetric QA methods. A historical review of those is presented, starting with longstanding techniques such as film and ion chamber in a phantom and progressing towards 3D and 4D dose reconstruction in the patient. Regarding patient-specific QA, we envision that the currently prevalent limited comparison of dose distributions in the phantom by γ-analysis will be eventually replaced by clinically meaningful patient dose analyses with improved sensitivity and specificity. In a larger sense, we envision a future of QA built upon lessons from the rich history of ''quality'' as a science and philosophy. This future will aim to improve quality (and ultimately reduce cost) via advanced commissioning processes that succeed in detecting and rooting out systematic errors upstream of patient treatment, thus reducing our reliance on, and the resource burden associated with, per-beam/per-plan inspection.

  18. Dosimetric quality assurance of highly conformal external beam treatments: from 2D phantom comparisons to 4D patient dose reconstruction

    Science.gov (United States)

    Feygelman, V.; Nelms, B.

    2013-06-01

    As IMRT technology continues to evolve, so do the dosimetric QA methods. A historical review of those is presented, starting with longstanding techniques such as film and ion chamber in a phantom and progressing towards 3D and 4D dose reconstruction in the patient. Regarding patient-specific QA, we envision that the currently prevalent limited comparison of dose distributions in the phantom by γ-analysis will be eventually replaced by clinically meaningful patient dose analyses with improved sensitivity and specificity. In a larger sense, we envision a future of QA built upon lessons from the rich history of "quality" as a science and philosophy. This future will aim to improve quality (and ultimately reduce cost) via advanced commissioning processes that succeed in detecting and rooting out systematic errors upstream of patient treatment, thus reducing our reliance on, and the resource burden associated with, per-beam/per-plan inspection.

  19. Iterative model reconstruction reduces calcified plaque volume in coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Károlyi, Mihály, E-mail: mihaly.karolyi@cirg.hu [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Szilveszter, Bálint, E-mail: szilveszter.balint@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Kolossváry, Márton, E-mail: martonandko@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Takx, Richard A.P, E-mail: richard.takx@gmail.com [Department of Radiology, University Medical Center Utrecht, 100 Heidelberglaan, 3584, CX Utrecht (Netherlands); Celeng, Csilla, E-mail: celengcsilla@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Bartykowszki, Andrea, E-mail: bartyandi@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Jermendy, Ádám L., E-mail: adam.jermendy@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Panajotu, Alexisz, E-mail: panajotualexisz@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Karády, Júlia, E-mail: karadyjulia@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); and others

    2017-02-15

    Objective: To assess the impact of iterative model reconstruction (IMR) on calcified plaque quantification as compared to filtered back projection reconstruction (FBP) and hybrid iterative reconstruction (HIR) in coronary computed tomography angiography (CTA). Methods: Raw image data of 52 patients who underwent 256-slice CTA were reconstructed with IMR, HIR and FBP. We evaluated qualitative, quantitative image quality parameters and quantified calcified and partially calcified plaque volumes using automated software. Results: Overall qualitative image quality significantly improved with HIR as compared to FBP, and further improved with IMR (p < 0.01 all). Contrast-to-noise ratios were improved with IMR, compared to HIR and FBP (51.0 [43.5–59.9], 20.3 [16.2–25.9] and 14.0 [11.2–17.7], respectively, all p < 0.01) Overall plaque volumes were lowest with IMR and highest with FBP (121.7 [79.3–168.4], 138.7 [90.6–191.7], 147.0 [100.7–183.6]). Similarly, calcified volumes (>130 HU) were decreased with IMR as compared to HIR and FBP (105.9 [62.1–144.6], 110.2 [63.8–166.6], 115.9 [81.7–164.2], respectively, p < 0.05 all). High-attenuation non-calcified volumes (90–129 HU) yielded similar values with FBP and HIR (p = 0.81), however it was lower with IMR (p < 0.05 both). Intermediate- (30–89 HU) and low-attenuation (<30 HU) non-calcified volumes showed no significant difference (p = 0.22 and p = 0.67, respectively). Conclusions: IMR improves image quality of coronary CTA and decreases calcified plaque volumes.

  20. Effect of reconstruction algorithm on image quality and identification of ground-glass opacities and partly solid nodules on low-dose thin-section CT: Experimental study using chest phantom

    International Nuclear Information System (INIS)

    Koyama, Hisanobu; Ohno, Yoshiharu; Kono, Atsushi A.; Kusaka, Akiko; Konishi, Minoru; Yoshii, Masaru; Sugimura, Kazuro

    2010-01-01

    Purpose: The purpose of this study was to assess the influence of reconstruction algorithm on identification and image quality of ground-glass opacities (GGOs) and partly solid nodules on low-dose thin-section CT. Materials and methods: A chest CT phantom including simulated GGOs and partly solid nodules was scanned with five different tube currents and reconstructed by using standard (A) and newly developed (B) high-resolution reconstruction algorithms, followed by visually assessment of identification and image quality of GGOs and partly solid nodules by two chest radiologists. Inter-observer agreement, ROC analysis and ANOVA were performed to compare identification and image quality of each data set with those of the standard reference. The standard reference used 120 mA s in conjunction with reconstruction algorithm A. Results: Kappa values (κ) of overall identification and image qualities were substantial or almost perfect (0.60 < κ). Assessment of identification showed that area under the curve of 25 mA reconstructed with reconstruction algorithm A was significantly lower than that of standard reference (p < 0.05), while assessment of image quality indicated that 50 mA s reconstructed with reconstruction algorithm A and 25 mA s reconstructed with both reconstruction algorithms were significantly lower than standard reference (p < 0.05). Conclusion: Reconstruction algorithm may be an important factor for identification and image quality of ground-glass opacities and partly solid nodules on low-dose CT examination.

  1. Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography

    International Nuclear Information System (INIS)

    Yang, Lin; Liang, Changhong; Zhuang, Jian; Huang, Meiping; Liu, Hui

    2017-01-01

    Hybrid iterative reconstruction can reduce image noise and produce better image quality compared with filtered back-projection (FBP), but few reports describe optimization of the iteration level. We optimized the iteration level of iDose"4 and evaluated image quality for pediatric cardiac CT angiography. Children (n = 160) with congenital heart disease were enrolled and divided into full-dose (n = 84) and half-dose (n = 76) groups. Four series were reconstructed using FBP, and iDose"4 levels 2, 4 and 6; we evaluated subjective quality of the series using a 5-grade scale and compared the series using a Kruskal-Wallis H test. For FBP and iDose"4-optimal images, we compared contrast-to-noise ratios (CNR) and size-specific dose estimates (SSDE) using a Student's t-test. We also compared diagnostic-accuracy of each group using a Kruskal-Wallis H test. Mean scores for iDose"4 level 4 were the best in both dose groups (all P < 0.05). CNR was improved in both groups with iDose"4 level 4 as compared with FBP. Mean decrease in SSDE was 53% in the half-dose group. Diagnostic accuracy for the four datasets were in the range 92.6-96.2% (no statistical difference). iDose"4 level 4 was optimal for both the full- and half-dose groups. Protocols with iDose"4 level 4 allowed 53% reduction in SSDE without significantly affecting image quality and diagnostic accuracy. (orig.)

  2. Structured data quality reports to improve EHR data quality.

    Science.gov (United States)

    Taggart, Jane; Liaw, Siaw-Teng; Yu, Hairong

    2015-12-01

    To examine whether a structured data quality report (SDQR) and feedback sessions with practice principals and managers improve the quality of routinely collected data in EHRs. The intervention was conducted in four general practices participating in the Fairfield neighborhood electronic Practice Based Research Network (ePBRN). Data were extracted from their clinical information systems and summarised as a SDQR to guide feedback to practice principals and managers at 0, 4, 8 and 12 months. Data quality (DQ) metrics included completeness, correctness, consistency and duplication of patient records. Information on data recording practices, data quality improvement, and utility of SDQRs was collected at the feedback sessions at the practices. The main outcome measure was change in the recording of clinical information and level of meeting Royal Australian College of General Practice (RACGP) targets. Birth date was 100% and gender 99% complete at baseline and maintained. DQ of all variables measured improved significantly (pImprovement was greatest with allergies. There was no significant change in duplicate records. SDQRs and feedback sessions support general practitioners and practice managers to focus on improving the recording of patient information. However, improved practice DQ, was not sufficient to meet RACGP targets. Randomised controlled studies are required to evaluate strategies to improve data quality and any associated improved safety and quality of care. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. [Quality assurance and quality improvement. Personal experiences and intentions].

    Science.gov (United States)

    Roche, B G; Sommer, C

    1995-01-01

    In may 1994 we were selected by the surgical Swiss association to make a study about quality in USA. During our travel we visited 3 types of institutions: Hospitals, National Institute of standard and Technology, Industry, Johnson & Johnson. We appreciate to compare 2 types of quality programs: Quality Assurance (QA) and Continuous Quality Improvement (CQI). In traditional healthcare circles, QA is the process established to meet external regulatory requirements and to assure that patient care is consistent with established standards. In a modern quality terms, QA outside of healthcare means designing a product or service, as well as controlling its production, so well that quality is inevitable. The ideas of W. Edward Deming is that there is never improvement just by inspection. He developed a theory based on 14 principles. A productive work is accomplished through processes. Understanding the variability of processes is a key to improve quality. Quality management sees each person in an organisation as part of one or more processes. The job of every worker is to receive the work of others, add value to that work, and supply it to the next person in the process. This is called the triple role the workers as customer, processor, and supplier. The main source of quality defects is problems in the process. The old assumption is that quality fails when people do the right thing wrong; the new assumption is that, more often, quality failures arise when people do the wrong think right. Exhortation, incentives and discipline of workers are unlikely to improve quality. If quality is failing when people do their jobs as designed, then exhorting them to do better is managerial nonsense. Modern quality theory is customer focused. Customers are identified internally and externally. The modern approach to quality is thoroughly grounded in scientific and statistical thinking. Like in medicine, the symptom is a defect in quality. The therapist of process must perform diagnostic

  4. Impact of a New Adaptive Statistical Iterative Reconstruction (ASIR)-V Algorithm on Image Quality in Coronary Computed Tomography Angiography.

    Science.gov (United States)

    Pontone, Gianluca; Muscogiuri, Giuseppe; Andreini, Daniele; Guaricci, Andrea I; Guglielmo, Marco; Baggiano, Andrea; Fazzari, Fabio; Mushtaq, Saima; Conte, Edoardo; Annoni, Andrea; Formenti, Alberto; Mancini, Elisabetta; Verdecchia, Massimo; Campari, Alessandro; Martini, Chiara; Gatti, Marco; Fusini, Laura; Bonfanti, Lorenzo; Consiglio, Elisa; Rabbat, Mark G; Bartorelli, Antonio L; Pepi, Mauro

    2018-03-27

    A new postprocessing algorithm named adaptive statistical iterative reconstruction (ASIR)-V has been recently introduced. The aim of this article was to analyze the impact of ASIR-V algorithm on signal, noise, and image quality of coronary computed tomography angiography. Fifty consecutive patients underwent clinically indicated coronary computed tomography angiography (Revolution CT; GE Healthcare, Milwaukee, WI). Images were reconstructed using filtered back projection and ASIR-V 0%, and a combination of filtered back projection and ASIR-V 20%-80% and ASIR-V 100%. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for left main coronary artery (LM), left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA) and were compared between the different postprocessing algorithms used. Similarly a four-point Likert image quality score of coronary segments was graded for each dataset and compared. A cutoff value of P ASIR-V 0%, ASIR-V 100% demonstrated a significant reduction of image noise in all coronaries (P ASIR-V 0%, SNR was significantly higher with ASIR-V 60% in LM (P ASIR-V 0%, CNR for ASIR-V ≥60% was significantly improved in LM (P ASIR-V ≥80%. ASIR-V 60% had significantly better Likert image quality scores compared to ASIR-V 0% in segment-, vessel-, and patient-based analyses (P ASIR-V 60% provides the optimal balance between image noise, SNR, CNR, and image quality. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  5. General surface reconstruction for cone-beam multislice spiral computed tomography

    International Nuclear Information System (INIS)

    Chen Laigao; Liang Yun; Heuscher, Dominic J.

    2003-01-01

    A new family of cone-beam reconstruction algorithm, the General Surface Reconstruction (GSR), is proposed and formulated in this paper for multislice spiral computed tomography (CT) reconstructions. It provides a general framework to allow the reconstruction of planar or nonplanar surfaces on a set of rebinned short-scan parallel beam projection data. An iterative surface formation method is proposed as an example to show the possibility to form nonplanar reconstruction surfaces to minimize the adverse effect between the collected cone-beam projection data and the reconstruction surfaces. The improvement in accuracy of the nonplanar surfaces over planar surfaces in the two-dimensional approximate cone-beam reconstructions is mathematically proved and demonstrated using numerical simulations. The proposed GSR algorithm is evaluated by the computer simulation of cone-beam spiral scanning geometry and various mathematical phantoms. The results demonstrate that the GSR algorithm generates much better image quality compared to conventional multislice reconstruction algorithms. For a table speed up to 100 mm per rotation, GSR demonstrates good image quality for both the low-contrast ball phantom and thorax phantom. All other performance parameters are comparable to the single-slice 180 deg. LI (linear interpolation) algorithm, which is considered the 'gold standard'. GSR also achieves high computing efficiency and good temporal resolution, making it an attractive alternative for the reconstruction of next generation multislice spiral CT data

  6. Solutions to Improve Educational Management Quality

    OpenAIRE

    Ramezan Jahanian; Masoomeh Motahari

    2013-01-01

    Nowadays, enhancing the quality in educational systems of different countries has gained especial importance and stand. Improving utilizing and increasing the quality in our country’s educational system is felt too. One of the utilizing factors in education system is to improve the educational management quality.In this article, effective factors in educational management quality and one of its improving solutions, thorough management quality, is analyzed.

  7. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    International Nuclear Information System (INIS)

    Wenz, Holger; Maros, Máté E.; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O.; Groden, Christoph; Henzler, Thomas

    2016-01-01

    •Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose.•Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT.•State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose. Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT. State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1–5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1–5) when compared to sequential cCT with a mean

  8. Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: comparison of multisegment and halfscan reconstruction approaches

    International Nuclear Information System (INIS)

    Dewey, Marc; Teige, Florian; Hamm, Bernd; Laule, Michael

    2007-01-01

    The lower the heart rate the better image quality in multislice computed tomography (MSCT) coronary angiography. We prospectively assessed the influence of heart rate on per-patient diagnostic accuracy and image quality of MSCT coronary angiography and compared adaptive multisegment and standard halfscan reconstruction. A consecutive cohort of 126 patients scheduled to undergo conventional coronary angiography was examined with 16-slice CT. For all heart rate groups, per-patient diagnostic accuracy was significantly higher for multisegment than halfscan reconstruction with values of 95 vs. 79% (p 74 bpm, 41 patients). Differences in diagnostic accuracy between adjacent heart rate groups were only significant for halfscan reconstruction for the comparison between the 65-74 and >74 bpm group (p < 0.05). The vessel lengths free of motion artifacts were significantly longer with multisegment reconstruction in all heart rate groups and for all coronary arteries (p < 0.005). For noninvasive MSCT coronary angiography, both per-patient diagnostic accuracy and image quality decline with increasing heart rate, and multisegment reconstruction at high heart rates yields similar results as standard halfscan reconstruction at low heart rates. (orig.)

  9. Computed Tomography Imaging of a Hip Prosthesis Using Iterative Model-Based Reconstruction and Orthopaedic Metal Artefact Reduction: A Quantitative Analysis.

    Science.gov (United States)

    Wellenberg, Ruud H H; Boomsma, Martijn F; van Osch, Jochen A C; Vlassenbroek, Alain; Milles, Julien; Edens, Mireille A; Streekstra, Geert J; Slump, Cornelis H; Maas, Mario

    To quantify the combined use of iterative model-based reconstruction (IMR) and orthopaedic metal artefact reduction (O-MAR) in reducing metal artefacts and improving image quality in a total hip arthroplasty phantom. Scans acquired at several dose levels and kVps were reconstructed with filtered back-projection (FBP), iterative reconstruction (iDose) and IMR, with and without O-MAR. Computed tomography (CT) numbers, noise levels, signal-to-noise-ratios and contrast-to-noise-ratios were analysed. Iterative model-based reconstruction results in overall improved image quality compared to iDose and FBP (P < 0.001). Orthopaedic metal artefact reduction is most effective in reducing severe metal artefacts improving CT number accuracy by 50%, 60%, and 63% (P < 0.05) and reducing noise by 1%, 62%, and 85% (P < 0.001) whereas improving signal-to-noise-ratios by 27%, 47%, and 46% (P < 0.001) and contrast-to-noise-ratios by 16%, 25%, and 19% (P < 0.001) with FBP, iDose, and IMR, respectively. The combined use of IMR and O-MAR strongly improves overall image quality and strongly reduces metal artefacts in the CT imaging of a total hip arthroplasty phantom.

  10. High-quality compressive ghost imaging

    Science.gov (United States)

    Huang, Heyan; Zhou, Cheng; Tian, Tian; Liu, Dongqi; Song, Lijun

    2018-04-01

    We propose a high-quality compressive ghost imaging method based on projected Landweber regularization and guided filter, which effectively reduce the undersampling noise and improve the resolution. In our scheme, the original object is reconstructed by decomposing of regularization and denoising steps instead of solving a minimization problem in compressive reconstruction process. The simulation and experimental results show that our method can obtain high ghost imaging quality in terms of PSNR and visual observation.

  11. Image quality of low-dose CCTA in obese patients: impact of high-definition computed tomography and adaptive statistical iterative reconstruction.

    Science.gov (United States)

    Gebhard, Cathérine; Fuchs, Tobias A; Fiechter, Michael; Stehli, Julia; Stähli, Barbara E; Gaemperli, Oliver; Kaufmann, Philipp A

    2013-10-01

    The accuracy of coronary computed tomography angiography (CCTA) in obese persons is compromised by increased image noise. We investigated CCTA image quality acquired on a high-definition 64-slice CT scanner using modern adaptive statistical iterative reconstruction (ASIR). Seventy overweight and obese patients (24 males; mean age 57 years, mean body mass index 33 kg/m(2)) were studied with clinically-indicated contrast enhanced CCTA. Thirty-five patients underwent a standard definition protocol with filtered backprojection reconstruction (SD-FBP) while 35 patients matched for gender, age, body mass index and coronary artery calcifications underwent a novel high definition protocol with ASIR (HD-ASIR). Segment by segment image quality was assessed using a four-point scale (1 = excellent, 2 = good, 3 = moderate, 4 = non-diagnostic) and revealed better scores for HD-ASIR compared to SD-FBP (1.5 ± 0.43 vs. 1.8 ± 0.48; p ASIR as compared to 1.4 ± 0.4 mm for SD-FBP (p ASIR (388.3 ± 109.6 versus 350.6 ± 90.3 Hounsfield Units, HU; p ASIR vs. SD-ASIR respectively). Compared to a standard definition backprojection protocol (SD-FBP), a newer high definition scan protocol in combination with ASIR (HD-ASIR) incrementally improved image quality and visualization of distal coronary artery segments in overweight and obese individuals, without increasing image noise and radiation dose.

  12. Alpha image reconstruction (AIR): A new iterative CT image reconstruction approach using voxel-wise alpha blending

    International Nuclear Information System (INIS)

    Hofmann, Christian; Sawall, Stefan; Knaup, Michael; Kachelrieß, Marc

    2014-01-01

    Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. Among vendors and researchers, however, there is no consensus of how to best achieve these aims. The general approach is to incorporatea priori knowledge into iterative image reconstruction, for example, by adding additional constraints to the cost function, which penalize variations between neighboring voxels. However, this approach to regularization in general poses a resolution noise trade-off because the stronger the regularization, and thus the noise reduction, the stronger the loss of spatial resolution and thus loss of anatomical detail. The authors propose a method which tries to improve this trade-off. The proposed reconstruction algorithm is called alpha image reconstruction (AIR). One starts with generating basis images, which emphasize certain desired image properties, like high resolution or low noise. The AIR algorithm reconstructs voxel-specific weighting coefficients that are applied to combine the basis images. By combining the desired properties of each basis image, one can generate an image with lower noise and maintained high contrast resolution thus improving the resolution noise trade-off. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and low contrast disks is simulated. A filtered backprojection (FBP) reconstruction with a Ram-Lak kernel is used as a reference reconstruction. The results of AIR are compared against the FBP results and against a penalized weighted least squares reconstruction which uses total variation as regularization. The simulations are based on the geometry of the Siemens Somatom Definition Flash scanner. To quantitatively assess image quality, the authors analyze line profiles through resolution patterns to define a contrast

  13. Improved electromagnetic tracking for catheter path reconstruction with application in high-dose-rate brachytherapy.

    Science.gov (United States)

    Lugez, Elodie; Sadjadi, Hossein; Joshi, Chandra P; Akl, Selim G; Fichtinger, Gabor

    2017-04-01

    Electromagnetic (EM) catheter tracking has recently been introduced in order to enable prompt and uncomplicated reconstruction of catheter paths in various clinical interventions. However, EM tracking is prone to measurement errors which can compromise the outcome of the procedure. Minimizing catheter tracking errors is therefore paramount to improve the path reconstruction accuracy. An extended Kalman filter (EKF) was employed to combine the nonlinear kinematic model of an EM sensor inside the catheter, with both its position and orientation measurements. The formulation of the kinematic model was based on the nonholonomic motion constraints of the EM sensor inside the catheter. Experimental verification was carried out in a clinical HDR suite. Ten catheters were inserted with mean curvatures varying from 0 to [Formula: see text] in a phantom. A miniaturized Ascension (Burlington, Vermont, USA) trakSTAR EM sensor (model 55) was threaded within each catheter at various speeds ranging from 7.4 to [Formula: see text]. The nonholonomic EKF was applied on the tracking data in order to statistically improve the EM tracking accuracy. A sample reconstruction error was defined at each point as the Euclidean distance between the estimated EM measurement and its corresponding ground truth. A path reconstruction accuracy was defined as the root mean square of the sample reconstruction errors, while the path reconstruction precision was defined as the standard deviation of these sample reconstruction errors. The impacts of sensor velocity and path curvature on the nonholonomic EKF method were determined. Finally, the nonholonomic EKF catheter path reconstructions were compared with the reconstructions provided by the manufacturer's filters under default settings, namely the AC wide notch and the DC adaptive filter. With a path reconstruction accuracy of 1.9 mm, the nonholonomic EKF surpassed the performance of the manufacturer's filters (2.4 mm) by 21% and the raw EM

  14. Neural network algorithm for image reconstruction using the grid friendly projections

    International Nuclear Information System (INIS)

    Cierniak, R.

    2011-01-01

    Full text: The presented paper describes a development of original approach to the reconstruction problem using a recurrent neural network. Particularly, the 'grid-friendly' angles of performed projections are selected according to the discrete Radon transform (DRT) concept to decrease the number of projections required. The methodology of our approach is consistent with analytical reconstruction algorithms. Reconstruction problem is reformulated in our approach to optimization problem. This problem is solved in present concept using method based on the maximum likelihood methodology. The reconstruction algorithm proposed in this work is consequently adapted for more practical discrete fan beam projections. Computer simulation results show that the neural network reconstruction algorithm designed to work in this way improves obtained results and outperforms conventional methods in reconstructed image quality. (author)

  15. How to Improve the Quality of Screening Endoscopy in Korea: National Endoscopy Quality Improvement Program.

    Science.gov (United States)

    Cho, Yu Kyung

    2016-07-01

    In Korea, gastric cancer screening, either esophagogastroduodenoscopy or upper gastrointestinal series (UGIS), is performed biennially for adults aged 40 years or older. Screening endoscopy has been shown to be associated with localized cancer detection and better than UGIS. However, the diagnostic sensitivity of detecting cancer is not satisfactory. The National Endoscopy Quality Improvement (QI) program was initiated in 2009 to enhance the quality of medical institutions and improve the effectiveness of the National Cancer Screening Program (NCSP). The Korean Society of Gastrointestinal Endoscopy developed quality standards through a broad systematic review of other endoscopic quality guidelines and discussions with experts. The standards comprise five domains: qualifications of endoscopists, endoscopic unit facilities and equipment, endoscopic procedure, endoscopy outcomes, and endoscopic reprocessing. After 5 years of the QI program, feedback surveys showed that the perception of QI and endoscopic practice improved substantially in all domains of quality, but the quality standards need to be revised. How to avoid missing cancer in endoscopic procedures in daily practice was reviewed, which can be applied to the mass screening endoscopy. To improve the quality and effectiveness of NCSP, key performance indicators, acceptable quality standards, regular audit, and appropriate reimbursement are necessary.

  16. Improvement of image quality using interpolated projection data estimation method in SPECT

    International Nuclear Information System (INIS)

    Takaki, Akihiro; Soma, Tsutomu; Murase, Kenya; Kojima, Akihiro; Asao, Kimie; Kamada, Shinya; Matsumoto, Masanori

    2009-01-01

    General data acquisition for single photon emission computed tomography (SPECT) is performed in 90 or 60 directions, with a coarse pitch of approximately 4-6 deg for a rotation of 360 deg or 180 deg, using a gamma camera. No data between adjacent projections will be sampled under these circumstances. The aim of the study was to develop a method to improve SPECT image quality by generating lacking projection data through interpolation of data obtained with a coarse pitch such as 6 deg. The projection data set at each individual degree in 360 directions was generated by a weighted average interpolation method from the projection data acquired with a coarse sampling angle (interpolated projection data estimation processing method, IPDE method). The IPDE method was applied to the numerical digital phantom data, actual phantom data and clinical brain data with Tc-99m ethyle cysteinate dimer (ECD). All SPECT images were reconstructed by the filtered back-projection method and compared with the original SPECT images. The results confirmed that streak artifacts decreased by apparently increasing a sampling number in SPECT after interpolation and also improved signal-to-noise (S/N) ratio of the root mean square uncertainty value. Furthermore, the normalized mean square error values, compared with standard images, had similar ones after interpolation. Moreover, the contrast and concentration ratios increased their effects after interpolation. These results indicate that effective improvement of image quality can be expected with interpolation. Thus, image quality and the ability to depict images can be improved while maintaining the present acquisition time and image quality. In addition, this can be achieved more effectively than at present even if the acquisition time is reduced. (author)

  17. Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT

    International Nuclear Information System (INIS)

    Wang, Jing; Gu, Xuejun

    2013-01-01

    Purpose: Image reconstruction and motion model estimation in four-dimensional cone-beam CT (4D-CBCT) are conventionally handled as two sequential steps. Due to the limited number of projections at each phase, the image quality of 4D-CBCT is degraded by view aliasing artifacts, and the accuracy of subsequent motion modeling is decreased by the inferior 4D-CBCT. The objective of this work is to enhance both the image quality of 4D-CBCT and the accuracy of motion model estimation with a novel strategy enabling simultaneous motion estimation and image reconstruction (SMEIR).Methods: The proposed SMEIR algorithm consists of two alternating steps: (1) model-based iterative image reconstruction to obtain a motion-compensated primary CBCT (m-pCBCT) and (2) motion model estimation to obtain an optimal set of deformation vector fields (DVFs) between the m-pCBCT and other 4D-CBCT phases. The motion-compensated image reconstruction is based on the simultaneous algebraic reconstruction technique (SART) coupled with total variation minimization. During the forward- and backprojection of SART, measured projections from an entire set of 4D-CBCT are used for reconstruction of the m-pCBCT by utilizing the updated DVF. The DVF is estimated by matching the forward projection of the deformed m-pCBCT and measured projections of other phases of 4D-CBCT. The performance of the SMEIR algorithm is quantitatively evaluated on a 4D NCAT phantom. The quality of reconstructed 4D images and the accuracy of tumor motion trajectory are assessed by comparing with those resulting from conventional sequential 4D-CBCT reconstructions (FDK and total variation minimization) and motion estimation (demons algorithm). The performance of the SMEIR algorithm is further evaluated by reconstructing a lung cancer patient 4D-CBCT.Results: Image quality of 4D-CBCT is greatly improved by the SMEIR algorithm in both phantom and patient studies. When all projections are used to reconstruct a 3D-CBCT by FDK, motion

  18. Workers' Objectives in Quality Improvement.

    Science.gov (United States)

    Brossard, Michel

    1990-01-01

    A case study of quality circles in an appliance factory found that circle members and nonmembers obtained better working conditions by improving quality through the direct impact of their work on the company's market position. The study of the quality improvement process shows that workers seek more than psychological rewards for their…

  19. Improved image quality with simultaneously reduced radiation exposure: Knowledge-based iterative model reconstruction algorithms for coronary CT angiography in a clinical setting.

    Science.gov (United States)

    André, Florian; Fortner, Philipp; Vembar, Mani; Mueller, Dirk; Stiller, Wolfram; Buss, Sebastian J; Kauczor, Hans-Ulrich; Katus, Hugo A; Korosoglou, Grigorios

    The aim of this study was to assess the potential for radiation dose reduction using knowledge-based iterative model reconstruction (K-IMR) algorithms in combination with ultra-low dose body mass index (BMI)-adapted protocols in coronary CT angiography (coronary CTA). Forty patients undergoing clinically indicated coronary CTA were randomly assigned to two groups with BMI-adapted (I: quality was significantly better in the ULD group using K-IMR CR 1 compared to FBP, iD 2 and iD 5 in the LD group, resulting in fewer non-diagnostic coronary segments (2.4% vs. 11.6%, 9.2% and 6.1%; p quality compared to LD protocols with FBP or hybrid iterative algorithms. Therefore, K-IMR allows for coronary CTA examinations with high diagnostic value and very low radiation exposure in clinical routine. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  20. Comparison of pure and hybrid iterative reconstruction techniques with conventional filtered back projection: Image quality assessment in the cervicothoracic region

    Energy Technology Data Exchange (ETDEWEB)

    Katsura, Masaki, E-mail: mkatsura-tky@umin.ac.jp [Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 (Japan); Sato, Jiro; Akahane, Masaaki; Matsuda, Izuru; Ishida, Masanori; Yasaka, Koichiro; Kunimatsu, Akira; Ohtomo, Kuni [Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 (Japan)

    2013-02-15

    Objectives: To evaluate the impact on image quality of three different image reconstruction techniques in the cervicothoracic region: model-based iterative reconstruction (MBIR), adaptive statistical iterative reconstruction (ASIR), and filtered back projection (FBP). Methods: Forty-four patients underwent unenhanced standard-of-care clinical computed tomography (CT) examinations which included the cervicothoracic region with a 64-row multidetector CT scanner. Images were reconstructed with FBP, 50% ASIR-FBP blending (ASIR50), and MBIR. Two radiologists assessed the cervicothoracic region in a blinded manner for streak artifacts, pixilated blotchy appearances, critical reproduction of visually sharp anatomical structures (thyroid gland, common carotid artery, and esophagus), and overall diagnostic acceptability. Objective image noise was measured in the internal jugular vein. Data were analyzed using the sign test and pair-wise Student's t-test. Results: MBIR images had significant lower quantitative image noise (8.88 ± 1.32) compared to ASIR images (18.63 ± 4.19, P < 0.01) and FBP images (26.52 ± 5.8, P < 0.01). Significant improvements in streak artifacts of the cervicothoracic region were observed with the use of MBIR (P < 0.001 each for MBIR vs. the other two image data sets for both readers), while no significant difference was observed between ASIR and FBP (P > 0.9 for ASIR vs. FBP for both readers). MBIR images were all diagnostically acceptable. Unique features of MBIR images included pixilated blotchy appearances, which did not adversely affect diagnostic acceptability. Conclusions: MBIR significantly improves image noise and streak artifacts of the cervicothoracic region over ASIR and FBP. MBIR is expected to enhance the value of CT examinations for areas where image noise and streak artifacts are problematic.

  1. Improved Wallis Dodging Algorithm for Large-Scale Super-Resolution Reconstruction Remote Sensing Images

    Directory of Open Access Journals (Sweden)

    Chong Fan

    2017-03-01

    Full Text Available A sub-block algorithm is usually applied in the super-resolution (SR reconstruction of images because of limitations in computer memory. However, the sub-block SR images can hardly achieve a seamless image mosaicking because of the uneven distribution of brightness and contrast among these sub-blocks. An effectively improved weighted Wallis dodging algorithm is proposed, aiming at the characteristic that SR reconstructed images are gray images with the same size and overlapping region. This algorithm can achieve consistency of image brightness and contrast. Meanwhile, a weighted adjustment sequence is presented to avoid the spatial propagation and accumulation of errors and the loss of image information caused by excessive computation. A seam line elimination method can share the partial dislocation in the seam line to the entire overlapping region with a smooth transition effect. Subsequently, the improved method is employed to remove the uneven illumination for 900 SR reconstructed images of ZY-3. Then, the overlapping image mosaic method is adopted to accomplish a seamless image mosaic based on the optimal seam line.

  2. Data on abiotic (nutrients and biotic (phytoplankton quality elements in Fortuna ecologically reconstructed area (Danube Delta Biosphere Reserve - Romania

    Directory of Open Access Journals (Sweden)

    TÖRÖK Liliana

    2013-12-01

    Full Text Available The impact of inorganic nutrient enrichment on reophillic ecosystems has been observed and intensively studied in many rivers. Due to the scarcity of information on ecological conditions in the channel-network of the Danube Delta it is very important to have reliable information on the trend of the abiotic and biotic quality elements in the Danube River and channel system – in order to fulfill the Water Framework Directive objectives and to implement the rehabilitation projects in area affected by nutrient pollution. The purpose of this paper is to present, analyze and discuss the results of evaluation of nutrient variation and phytoplankton quantification obtained in Fortuna area - one of the seven reconstructed areas of the Danube Delta Biosphere Reserve. In order to improve the quality of data on phytoplankton biomass distribution from Fortuna area, in the summer of 2008 there has been used a submersible spectrofluorometer with automatic algae class determination and chlorophyll analysis (bbe Fluoro Probe. According to the results of analyses on relation between phytoplankton communities and water-column, the phytoplankton development in the channel network of the Fortuna reconstructed area seems to be influenced mainly by nitrogen concentration than by phosphorus concentration, as in case of phytoplankton development in Danube Delta’s lakes

  3. Creating Quality Improvement Culture in Public Health Agencies

    Science.gov (United States)

    Mahanna, Elizabeth; Joly, Brenda; Zelek, Michael; Riley, William; Verma, Pooja; Fisher, Jessica Solomon

    2014-01-01

    Objectives. We conducted case studies of 10 agencies that participated in early quality improvement efforts. Methods. The agencies participated in a project conducted by the National Association of County and City Health Officials (2007–2008). Case study participants included health directors and quality improvement team leaders and members. We implemented multiple qualitative analysis processes, including cross-case analysis and logic modeling. We categorized agencies according to the extent to which they had developed a quality improvement culture. Results. Agencies were conducting informal quality improvement projects (n = 4), conducting formal quality improvement projects (n = 3), or creating a quality improvement culture (n = 4). Agencies conducting formal quality improvement and creating a quality improvement culture had leadership support for quality improvement, participated in national quality improvement initiatives, had a greater number of staff trained in quality improvement and quality improvement teams that met regularly with decision-making authority. Agencies conducting informal quality improvement were likely to report that accreditation is the major driver for quality improvement work. Agencies creating a quality improvement culture were more likely to have a history of evidence-based decision-making and use quality improvement to address emerging issues. Conclusions. Our findings support previous research and add the roles of national public health accreditation and emerging issues as factors in agencies’ ability to create and sustain a quality improvement culture. PMID:24228680

  4. Creating quality improvement culture in public health agencies.

    Science.gov (United States)

    Davis, Mary V; Mahanna, Elizabeth; Joly, Brenda; Zelek, Michael; Riley, William; Verma, Pooja; Fisher, Jessica Solomon

    2014-01-01

    We conducted case studies of 10 agencies that participated in early quality improvement efforts. The agencies participated in a project conducted by the National Association of County and City Health Officials (2007-2008). Case study participants included health directors and quality improvement team leaders and members. We implemented multiple qualitative analysis processes, including cross-case analysis and logic modeling. We categorized agencies according to the extent to which they had developed a quality improvement culture. Agencies were conducting informal quality improvement projects (n = 4), conducting formal quality improvement projects (n = 3), or creating a quality improvement culture (n = 4). Agencies conducting formal quality improvement and creating a quality improvement culture had leadership support for quality improvement, participated in national quality improvement initiatives, had a greater number of staff trained in quality improvement and quality improvement teams that met regularly with decision-making authority. Agencies conducting informal quality improvement were likely to report that accreditation is the major driver for quality improvement work. Agencies creating a quality improvement culture were more likely to have a history of evidence-based decision-making and use quality improvement to address emerging issues. Our findings support previous research and add the roles of national public health accreditation and emerging issues as factors in agencies' ability to create and sustain a quality improvement culture.

  5. Iterative reconstruction reduces abdominal CT dose

    International Nuclear Information System (INIS)

    Martinsen, Anne Catrine Trægde; Sæther, Hilde Kjernlie; Hol, Per Kristian; Olsen, Dag Rune; Skaane, Per

    2012-01-01

    Objective: In medical imaging, lowering radiation dose from computed tomography scanning, without reducing diagnostic performance is a desired achievement. Iterative image reconstruction may be one tool to achieve dose reduction. This study reports the diagnostic performance using a blending of 50% statistical iterative reconstruction (ASIR) and filtered back projection reconstruction (FBP) compared to standard FBP image reconstruction at different dose levels for liver phantom examinations. Methods: An anthropomorphic liver phantom was scanned at 250, 185, 155, 140, 120 and 100 mA s, on a 64-slice GE Lightspeed VCT scanner. All scans were reconstructed with ASIR and FBP. Four readers evaluated independently on a 5-point scale 21 images, each containing 32 test sectors. In total 672 areas were assessed. ROC analysis was used to evaluate the differences. Results: There was a difference in AUC between the 250 mA s FBP images and the 120 and 100 mA s FBP images. ASIR reconstruction gave a significantly higher diagnostic performance compared to standard reconstruction at 100 mA s. Conclusion: A blending of 50–90% ASIR and FBP may improve image quality of low dose CT examinations of the liver, and thus give a potential for reducing radiation dose.

  6. Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective

    International Nuclear Information System (INIS)

    Brady, S. L.; Yee, B. S.; Kaufman, R. A.

    2012-01-01

    Purpose: This study demonstrates a means of implementing an adaptive statistical iterative reconstruction (ASiR™) technique for dose reduction in computed tomography (CT) while maintaining similar noise levels in the reconstructed image. The effects of image quality and noise texture were assessed at all implementation levels of ASiR™. Empirically derived dose reduction limits were established for ASiR™ for imaging of the trunk for a pediatric oncology population ranging from 1 yr old through adolescence/adulthood. Methods: Image quality was assessed using metrics established by the American College of Radiology (ACR) CT accreditation program. Each image quality metric was tested using the ACR CT phantom with 0%–100% ASiR™ blended with filtered back projection (FBP) reconstructed images. Additionally, the noise power spectrum (NPS) was calculated for three common reconstruction filters of the trunk. The empirically derived limitations on ASiR™ implementation for dose reduction were assessed using (1, 5, 10) yr old and adolescent/adult anthropomorphic phantoms. To assess dose reduction limits, the phantoms were scanned in increments of increased noise index (decrementing mA using automatic tube current modulation) balanced with ASiR™ reconstruction to maintain noise equivalence of the 0% ASiR™ image. Results: The ASiR™ algorithm did not produce any unfavorable effects on image quality as assessed by ACR criteria. Conversely, low-contrast resolution was found to improve due to the reduction of noise in the reconstructed images. NPS calculations demonstrated that images with lower frequency noise had lower noise variance and coarser graininess at progressively higher percentages of ASiR™ reconstruction; and in spite of the similar magnitudes of noise, the image reconstructed with 50% or more ASiR™ presented a more smoothed appearance than the pre-ASiR™ 100% FBP image. Finally, relative to non-ASiR™ images with 100% of standard dose across the

  7. Iterative CT reconstruction via minimizing adaptively reweighted total variation.

    Science.gov (United States)

    Zhu, Lei; Niu, Tianye; Petrongolo, Michael

    2014-01-01

    Iterative reconstruction via total variation (TV) minimization has demonstrated great successes in accurate CT imaging from under-sampled projections. When projections are further reduced, over-smoothing artifacts appear in the current reconstruction especially around the structure boundaries. We propose a practical algorithm to improve TV-minimization based CT reconstruction on very few projection data. Based on the theory of compressed sensing, the L-0 norm approach is more desirable to further reduce the projection views. To overcome the computational difficulty of the non-convex optimization of the L-0 norm, we implement an adaptive weighting scheme to approximate the solution via a series of TV minimizations for practical use in CT reconstruction. The weight on TV is initialized as uniform ones, and is automatically changed based on the gradient of the reconstructed image from the previous iteration. The iteration stops when a small difference between the weighted TV values is observed on two consecutive reconstructed images. We evaluate the proposed algorithm on both a digital phantom and a physical phantom. Using 20 equiangular projections, our method reduces reconstruction errors in the conventional TV minimization by a factor of more than 5, with improved spatial resolution. By adaptively reweighting TV in iterative CT reconstruction, we successfully further reduce the projection number for the same or better image quality.

  8. Cardiovascular CT angiography in neonates and children : Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

    NARCIS (Netherlands)

    Tricarico, Francesco; Hlavacek, Anthony M.; Schoepf, U. Joseph; Ebersberger, Ullrich; Nance, John W.; Vliegenthart, Rozemarijn; Cho, Young Jun; Spears, J. Reid; Secchi, Francesco; Savino, Giancarlo; Marano, Riccardo; Schoenberg, Stefan O.; Bonomo, Lorenzo; Apfaltrer, Paul

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose

  9. A Hairy Situation: Laser Hair Removal after Oral Reconstruction.

    Science.gov (United States)

    Shields, Bridget E; Moye, Molly S; Bayon, Rodrigo; Sperry, Steven M; Wanat, Karolyn A

    2018-03-01

    To present a case series of 4 patients who underwent postoperative hair removal using the long-pulsed Alexandrite or Nd:YAG laser following intraoral cutaneous flap reconstruction. Patients underwent epilation in dermatology clinic with long-pulsed Alexandrite or Nd:YAG lasers, spaced 8 weeks apart, until hair removal was achieved. All patients achieved improvement in hair removal regardless of initial flap donor site with significant improvement in quality of life and minimal side effects. The long-pulsed Alexandrite and Nd:YAG represent safe and effective treatment options to improve patient quality of life following intraoral flap repair following excision of malignancy.

  10. Compressively sampled MR image reconstruction using generalized thresholding iterative algorithm

    Science.gov (United States)

    Elahi, Sana; kaleem, Muhammad; Omer, Hammad

    2018-01-01

    Compressed sensing (CS) is an emerging area of interest in Magnetic Resonance Imaging (MRI). CS is used for the reconstruction of the images from a very limited number of samples in k-space. This significantly reduces the MRI data acquisition time. One important requirement for signal recovery in CS is the use of an appropriate non-linear reconstruction algorithm. It is a challenging task to choose a reconstruction algorithm that would accurately reconstruct the MR images from the under-sampled k-space data. Various algorithms have been used to solve the system of non-linear equations for better image quality and reconstruction speed in CS. In the recent past, iterative soft thresholding algorithm (ISTA) has been introduced in CS-MRI. This algorithm directly cancels the incoherent artifacts produced because of the undersampling in k -space. This paper introduces an improved iterative algorithm based on p -thresholding technique for CS-MRI image reconstruction. The use of p -thresholding function promotes sparsity in the image which is a key factor for CS based image reconstruction. The p -thresholding based iterative algorithm is a modification of ISTA, and minimizes non-convex functions. It has been shown that the proposed p -thresholding iterative algorithm can be used effectively to recover fully sampled image from the under-sampled data in MRI. The performance of the proposed method is verified using simulated and actual MRI data taken at St. Mary's Hospital, London. The quality of the reconstructed images is measured in terms of peak signal-to-noise ratio (PSNR), artifact power (AP), and structural similarity index measure (SSIM). The proposed approach shows improved performance when compared to other iterative algorithms based on log thresholding, soft thresholding and hard thresholding techniques at different reduction factors.

  11. DQS advisor: a visual interface and knowledge-based system to balance dose, quality, and reconstruction speed in iterative CT reconstruction with application to NLM-regularization

    International Nuclear Information System (INIS)

    Zheng, Z; Papenhausen, E; Mueller, K

    2013-01-01

    Motivated by growing concerns with regards to the x-ray dose delivered to the patient, low-dose computed tomography (CT) has gained substantial interest in recent years. However, achieving high-quality CT reconstructions from the limited projection data collected at reduced x-ray radiation is challenging, and iterative algorithms have been shown to perform much better than conventional analytical schemes in these cases. A problem with iterative methods in general is that they require users to set many parameters, and if set incorrectly high reconstruction time and/or low image quality are likely consequences. Since the interactions among parameters can be complex and thus effective settings can be difficult to identify for a given scanning scenario, these choices are often left to a highly-experienced human expert. To help alleviate this problem, we devise a computer-based assistant for this purpose, called dose, quality and speed (DQS)-advisor. It allows users to balance the three most important CT metrics–-DQS-–by ways of an intuitive visual interface. Using a known gold-standard, the system uses the ant-colony optimization algorithm to generate the most effective parameter settings for a comprehensive set of DQS configurations. A visual interface then presents the numerical outcome of this optimization, while a matrix display allows users to compare the corresponding images. The interface allows users to intuitively trade-off GPU-enabled reconstruction speed with quality and dose, while the system picks the associated parameter settings automatically. Further, once the knowledge has been generated, it can be used to correctly set the parameters for any new CT scan taken at similar scenarios. (paper)

  12. Anatomic single-bundle anterior cruciate ligament reconstruction improves walking economy: hamstrings tendon versus patellar tendon grafts.

    Science.gov (United States)

    Iliopoulos, Efthymios; Galanis, Nikiforos; Zafeiridis, Andreas; Iosifidis, Michael; Papadopoulos, Pericles; Potoupnis, Michael; Geladas, Nikolaos; Vrabas, Ioannis S; Kirkos, John

    2017-10-01

    Anterior cruciate ligament (ACL) injury is associated with a pathologic gait pattern and increased energy cost during locomotion. ACL reconstruction could improve the gait pattern. Hamstrings tendon (HAM) and bone-patellar tendon-bone (BPTB) grafts are usually used for reconstruction. The aim of this study was to compare the efficacy of anatomic ACL reconstruction with HAM and BPTB grafts on improving and normalizing the energy cost and physiologic reserves during flat, uphill, and downhill walking. Twenty male subjects with unilateral ACL injuries were randomly assigned to ACL reconstruction with a HAM (n = 10) or BPTB (n = 10) graft. Ten matched controls were also enrolled. All participants performed three 8-min walking tasks at 0, +10, and -10 % gradients before and 9 months after surgery. Energy cost (oxygen consumption, VO 2 ), heart rate (HR), and ventilation (VE) were measured. Lysholm/IKDC scores were recorded. Pre-operatively, VO 2 , HR, and VE were higher in the HAM and BPTB groups than in controls during walking at 0, +10, and -10 % gradients (p energy cost and nearly normalized locomotion economy and cardiorespiratory reserves during flat, uphill, and downhill walking. The improved locomotion economy is an additional benefit of anatomic ACL reconstruction, irrespective of the type of graft used, that the orthopaedic surgeons should consider. II.

  13. Filter and slice thickness selection in SPECT image reconstruction

    International Nuclear Information System (INIS)

    Ivanovic, M.; Weber, D.A.; Wilson, G.A.; O'Mara, R.E.

    1985-01-01

    The choice of filter and slice thickness in SPECT image reconstruction as function of activity and linear and angular sampling were investigated in phantom and patient imaging studies. Reconstructed transverse and longitudinal spatial resolution of the system were measured using a line source in a water filled phantom. Phantom studies included measurements of the Data Spectrum phantom; clinical studies included tomographic procedures in 40 patients undergoing imaging of the temporomandibular joint. Slices of the phantom and patient images were evaluated for spatial of the phantom and patient images were evaluated for spatial resolution, noise, and image quality. Major findings include; spatial resolution and image quality improve with increasing linear sampling frequencies over the range of 4-8 mm/p in the phantom images, best spatial resolution and image quality in clinical images were observed at a linear sampling frequency of 6mm/p, Shepp and Logan filter gives the best spatial resolution for phantom studies at the lowest linear sampling frequency; smoothed Shepp and Logan filter provides best quality images without loss of resolution at higher frequencies and, spatial resolution and image quality improve with increased angular sampling frequency in the phantom at 40 c/p but appear to be independent of angular sampling frequency at 400 c/p

  14. Does acellular dermal matrix really improve aesthetic outcome in tissue expander/implant-based breast reconstruction?

    Science.gov (United States)

    Ibrahim, Ahmed M S; Koolen, Pieter G L; Ganor, Oren; Markarian, Mark K; Tobias, Adam M; Lee, Bernard T; Lin, Samuel J; Mureau, Marc A M

    2015-06-01

    The expectation for improved results by women undergoing postmastectomy reconstruction has steadily risen. A majority of these operations are tissue expander/implant-based breast reconstructions. Acellular dermal matrix (ADM) offers numerous advantages in these procedures. Thus far, the evidence to justify improved aesthetic outcome has solely been based on surgeon opinion. The purpose of this study was to assess aesthetic outcome following ADM use in tissue expander/implant-based breast reconstruction by a panel of blinded plastic surgeons. Mean aesthetic results of patients who underwent tissue expander/implant-based breast reconstruction with (n = 18) or without ADM (n = 20) were assessed with objective grading of preoperative and postoperative photographs by five independent blinded plastic surgeons. Absolute observed agreement as well as weighted Fleiss Kappa (κ) test statistics were calculated to assess inter-rater variability. When ADM was incorporated, the overall aesthetic score was improved by an average of 12.1 %. In addition, subscale analyses revealed improvements in breast contour (35.2 %), implant placement (20.7 %), lower pole projection (16.7 %), and inframammary fold definition (13.8 %). Contour (p = 0.039), implant placement (p = 0.021), and overall aesthetic score (p = 0.022) reached statistical significance. Inter-rater reliability showed mostly moderate agreement. Mean aesthetic scores were higher in the ADM-assisted breast reconstruction cohort including the total aesthetic score which was statistically significant. Aesthetic outcome alone may justify the added expense of incorporating biologic mesh. Moreover, ADM has other benefits which may render it cost-effective. Larger prospective studies are needed to provide plastic surgeons with more definitive guidelines for ADM use. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the

  15. Do Clinical Practice Guidelines Improve Quality?

    Science.gov (United States)

    Baldassari, Cristina M

    2017-07-01

    Controversy exists surrounding how to best define and assess quality in the health care setting. Clinical practice guidelines (CPGs) have been developed to improve the quality of medical care by highlighting key clinical recommendations based on recent evidence. However, data linking CPGs to improvements in outcomes in otolaryngology are lacking. Numerous barriers contribute to difficulties in translating CPGs to improvements in quality. Future initiatives are needed to improve CPG adherence and define the impact of CPG recommendations on the quality of otolaryngologic care provided to our patients.

  16. SQIMSO: Quality Improvement for Small Software Organizations

    OpenAIRE

    Rabih Zeineddine; Nashat Mansour

    2005-01-01

    Software quality improvement process remains incomplete if it is not initiated and conducted through a wide improvement program that considers process quality improvement, product quality improvement and evolution of human resources. But, small software organizations are not capable of bearing the cost of establishing software process improvement programs. In this work, we propose a new software quality improvement model for small organizations, SQIMSO, based on three ...

  17. Aesthetic refinements in reconstructive microsurgery of the lower leg.

    Science.gov (United States)

    Rainer, Christian; Schwabegger, Anton H; Gardetto, Alexander; Schoeller, Thomas; Hussl, Heribert; Ninkovic, Milomir M

    2004-02-01

    Even if a surgical procedure is performed for reconstructive and functional reasons, a plastic surgeon must be responsible for the visible result of the work and for the social reintegration of the patient; therefore, the aesthetic appearance of a microsurgically reconstructed lower leg must be considered. Based on the experience of 124 free-tissue transfers to the lower leg performed in 112 patients between January 1994 and March 2001 (110 [88.7 percent] were transferred successfully), three cases are presented. Considerations concerning flap selection and technical refinements in designing and tailoring microvascular flaps to improve the quality of reconstruction, also according to the aesthetic appearance, are discussed.

  18. Analytic 3D image reconstruction using all detected events

    International Nuclear Information System (INIS)

    Kinahan, P.E.; Rogers, J.G.

    1988-11-01

    We present the results of testing a previously presented algorithm for three-dimensional image reconstruction that uses all gamma-ray coincidence events detected by a PET volume-imaging scanner. By using two iterations of an analytic filter-backprojection method, the algorithm is not constrained by the requirement of a spatially invariant detector point spread function, which limits normal analytic techniques. Removing this constraint allows the incorporation of all detected events, regardless of orientation, which improves the statistical quality of the final reconstructed image

  19. Comparison of pure and hybrid iterative reconstruction techniques with conventional filtered back projection: Image quality assessment in the cervicothoracic region

    International Nuclear Information System (INIS)

    Katsura, Masaki; Sato, Jiro; Akahane, Masaaki; Matsuda, Izuru; Ishida, Masanori; Yasaka, Koichiro; Kunimatsu, Akira; Ohtomo, Kuni

    2013-01-01

    Objectives: To evaluate the impact on image quality of three different image reconstruction techniques in the cervicothoracic region: model-based iterative reconstruction (MBIR), adaptive statistical iterative reconstruction (ASIR), and filtered back projection (FBP). Methods: Forty-four patients underwent unenhanced standard-of-care clinical computed tomography (CT) examinations which included the cervicothoracic region with a 64-row multidetector CT scanner. Images were reconstructed with FBP, 50% ASIR-FBP blending (ASIR50), and MBIR. Two radiologists assessed the cervicothoracic region in a blinded manner for streak artifacts, pixilated blotchy appearances, critical reproduction of visually sharp anatomical structures (thyroid gland, common carotid artery, and esophagus), and overall diagnostic acceptability. Objective image noise was measured in the internal jugular vein. Data were analyzed using the sign test and pair-wise Student's t-test. Results: MBIR images had significant lower quantitative image noise (8.88 ± 1.32) compared to ASIR images (18.63 ± 4.19, P 0.9 for ASIR vs. FBP for both readers). MBIR images were all diagnostically acceptable. Unique features of MBIR images included pixilated blotchy appearances, which did not adversely affect diagnostic acceptability. Conclusions: MBIR significantly improves image noise and streak artifacts of the cervicothoracic region over ASIR and FBP. MBIR is expected to enhance the value of CT examinations for areas where image noise and streak artifacts are problematic

  20. Optimization of the Reconstruction Interval in Neurovascular 4D-CTA Imaging

    Science.gov (United States)

    Hoogenboom, T.C.H.; van Beurden, R.M.J.; van Teylingen, B.; Schenk, B.; Willems, P.W.A.

    2012-01-01

    Summary Time resolved whole brain CT angiography (4D-CTA) is a novel imaging technology providing information regarding blood flow. One of the factors that influence the diagnostic value of this examination is the temporal resolution, which is affected by the gantry rotation speed during acquisition and the reconstruction interval during post-processing. Post-processing determines the time spacing between two reconstructed volumes and, unlike rotation speed, does not affect radiation burden. The data sets of six patients who underwent a cranial 4D-CTA were used for this study. Raw data was acquired using a 320-slice scanner with a rotation speed of 2 Hz. The arterial to venous passage of an intravenous contrast bolus was captured during a 15 s continuous scan. The raw data was reconstructed using four different reconstruction-intervals: 0.2, 0.3, 0.5 and 1.0 s. The results were rated by two observers using a standardized score sheet. The appearance of each lesion was rated correctly in all readings. Scoring for quality of temporal resolution revealed a stepwise improvement from the 1.0 s interval to the 0.3 s interval, while no discernable improvement was noted between the 0.3 s and 0.2 s interval. An increase in temporal resolution may improve the diagnostic quality of cranial 4D-CTA. Using a rotation speed of 0.5 s, the optimal reconstruction interval appears to be 0.3 s, beyond which, changes can no longer be discerned. PMID:23217631

  1. Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Lin; Liang, Changhong [Southern Medical University, Guangzhou (China); Guangdong Academy of Medical Sciences, Dept. of Radiology, Guangdong General Hospital, Guangzhou (China); Zhuang, Jian [Guangdong Academy of Medical Sciences, Dept. of Cardiac Surgery, Guangdong Cardiovascular Inst., Guangdong Provincial Key Lab. of South China Structural Heart Disease, Guangdong General Hospital, Guangzhou (China); Huang, Meiping [Guangdong Academy of Medical Sciences, Dept. of Radiology, Guangdong General Hospital, Guangzhou (China); Guangdong Academy of Medical Sciences, Dept. of Catheterization Lab, Guangdong Cardiovascular Inst., Guangdong Provincial Key Lab. of South China Structural Heart Disease, Guangdong General Hospital, Guangzhou (China); Liu, Hui [Guangdong Academy of Medical Sciences, Dept. of Radiology, Guangdong General Hospital, Guangzhou (China)

    2017-01-15

    Hybrid iterative reconstruction can reduce image noise and produce better image quality compared with filtered back-projection (FBP), but few reports describe optimization of the iteration level. We optimized the iteration level of iDose{sup 4} and evaluated image quality for pediatric cardiac CT angiography. Children (n = 160) with congenital heart disease were enrolled and divided into full-dose (n = 84) and half-dose (n = 76) groups. Four series were reconstructed using FBP, and iDose{sup 4} levels 2, 4 and 6; we evaluated subjective quality of the series using a 5-grade scale and compared the series using a Kruskal-Wallis H test. For FBP and iDose{sup 4}-optimal images, we compared contrast-to-noise ratios (CNR) and size-specific dose estimates (SSDE) using a Student's t-test. We also compared diagnostic-accuracy of each group using a Kruskal-Wallis H test. Mean scores for iDose{sup 4} level 4 were the best in both dose groups (all P < 0.05). CNR was improved in both groups with iDose{sup 4} level 4 as compared with FBP. Mean decrease in SSDE was 53% in the half-dose group. Diagnostic accuracy for the four datasets were in the range 92.6-96.2% (no statistical difference). iDose{sup 4} level 4 was optimal for both the full- and half-dose groups. Protocols with iDose{sup 4} level 4 allowed 53% reduction in SSDE without significantly affecting image quality and diagnostic accuracy. (orig.)

  2. Multiscale bilateral filtering for improving image quality in digital breast tomosynthesis

    Science.gov (United States)

    Lu, Yao; Chan, Heang-Ping; Wei, Jun; Hadjiiski, Lubomir M.; Samala, Ravi K.

    2015-01-01

    Purpose: Detection of subtle microcalcifications in digital breast tomosynthesis (DBT) is a challenging task because of the large, noisy DBT volume. It is important to enhance the contrast-to-noise ratio (CNR) of microcalcifications in DBT reconstruction. Most regularization methods depend on local gradient and may treat the ill-defined margins or subtle spiculations of masses and subtle microcalcifications as noise because of their small gradient. The authors developed a new multiscale bilateral filtering (MSBF) regularization method for the simultaneous algebraic reconstruction technique (SART) to improve the CNR of microcalcifications without compromising the quality of masses. Methods: The MSBF exploits a multiscale structure of DBT images to suppress noise and selectively enhance high frequency structures. At the end of each SART iteration, every DBT slice is decomposed into several frequency bands via Laplacian pyramid decomposition. No regularization is applied to the low frequency bands so that subtle edges of masses and structured background are preserved. Bilateral filtering is applied to the high frequency bands to enhance microcalcifications while suppressing noise. The regularized DBT images are used for updating in the next SART iteration. The new MSBF method was compared with the nonconvex total p-variation (TpV) method for noise regularization with SART. A GE GEN2 prototype DBT system was used for acquisition of projections at 21 angles in 3° increments over a ±30° range. The reconstruction image quality with no regularization (NR) and that with the two regularization methods were compared using the DBT scans of a heterogeneous breast phantom and several human subjects with masses and microcalcifications. The CNR and the full width at half maximum (FWHM) of the line profiles of microcalcifications and across the spiculations within their in-focus DBT slices were used as image quality measures. Results: The MSBF method reduced contouring artifacts

  3. Quality improvement education to improve performance on ulcerative colitis quality measures and care processes aligned with National Quality Strategy priorities.

    Science.gov (United States)

    Greene, Laurence; Moreo, Kathleen

    2015-01-01

    Studies on inflammatory bowel disease (IBD) have reported suboptimal approaches to patient care. In the United States, the findings have motivated leading gastroenterology organizations to call for initiatives that support clinicians in aligning their practices with quality measures for IBD and priorities of the National Quality Strategy (NQS). We designed and implemented a quality improvement (QI) education program on ulcerative colitis in which patient charts were audited for 30 gastroenterologists before (n = 300 charts) and after (n = 290 charts) they participated in QI-focused educational activities. Charts were audited for nine measures, selected for their alignment with four NQS priorities: making care safer, ensuring patient engagement, promoting communication, and promoting effective treatment practices. Four of the measures, including guideline-directed vaccinations and assessments of disease type and activity, were part of the CMS Physician Quality Reporting System (PQRS). The other five measures involved counseling patients on various topics in ulcerative colitis management, documentation of side effects, assessment of adherence status, and simplification of dosing. The gastroenterologists also completed baseline and post-education surveys designed to assess qualitative outcomes. One of the educational interventions was a private audit feedback session conducted for each gastroenterologist. The sessions were designed to support participants in identifying measures reflecting suboptimal care quality and developing action plans for improvement. In continuous improvement cycles, follow-up interventions included QI tools and educational monographs. Across the nine chart variables, post-education improvements ranged from 0% to 48%, with a mean improvement of 15.9%. Survey findings revealed improvements in self-reported understanding of quality measures and intentions to apply them to practice, and lower rates of perceived significant barriers to high-quality

  4. Hydroxyapatite-doped polycaprolactone nanofiber membrane improves tendon-bone interface healing for anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Han, Fei; Zhang, Peng; Sun, Yaying; Lin, Chao; Zhao, Peng; Chen, Jiwu

    2015-01-01

    Hamstring tendon autograft is a routine graft for anterior cruciate ligament (ACL) reconstruction. However, ways of improving the healing between the tendon and bone is often overlooked in clinical practice. This issue can be addressed by using a biomimetic scaffold. Herein, a biomimetic nanofiber membrane of polycaprolactone/nanohydroxyapatite/collagen (PCL/nHAp/Col) is fabricated that mimics the composition of native bone tissue for promoting tendon-bone healing. This membrane has good cytocompatibility, allowing for osteoblast cell adhesion and growth and bone formation. As a result, MC3T3 cells reveal a higher mineralization level in PCL/nHAp/Col membrane compared with PCL membrane alone. Further in vivo studies in ACL reconstruction in a rabbit model shows that PCL/nHAp/Col-wrapped tendon may afford superior tissue integration to nonwrapped tendon in the interface between the tendon and host bone as well as improved mechanical strength. This study shows that PCL/nHAp/Col nanofiber membrane wrapping of autologous tendon is effective for improving tendon healing with host bone in ACL reconstruction.

  5. Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT

    Energy Technology Data Exchange (ETDEWEB)

    Varrone, Andrea; Sjoeholm, Nils; Gulyas, Balazs; Halldin, Christer; Farde, Lars [Karolinska Hospital, Karolinska Institutet, Department of Clinical Neuroscience, Psychiatry Section and Stockholm Brain Institute, Stockholm (Sweden); Eriksson, Lars [Karolinska Hospital, Karolinska Institutet, Department of Clinical Neuroscience, Psychiatry Section and Stockholm Brain Institute, Stockholm (Sweden); Siemens Molecular Imaging, Knoxville, TN (United States); University of Stockholm, Department of Physics, Stockholm (Sweden)

    2009-10-15

    Image reconstruction including the modelling of the point spread function (PSF) is an approach improving the resolution of the PET images. This study assessed the quantitative improvements provided by the implementation of the PSF modelling in the reconstruction of the PET data using the High Resolution Research Tomograph (HRRT). Measurements were performed on the NEMA-IEC/2001 (Image Quality) phantom for image quality and on an anthropomorphic brain phantom (STEPBRAIN). PSF reconstruction was also applied to PET measurements in two cynomolgus monkeys examined with [{sup 18}F]FE-PE2I (dopamine transporter) and with [{sup 11}C]MNPA (D{sub 2} receptor), and in one human subject examined with [{sup 11}C]raclopride (D{sub 2} receptor). PSF reconstruction increased the recovery coefficient (RC) in the NEMA phantom by 11-40% and the grey to white matter ratio in the STEPBRAIN phantom by 17%. PSF reconstruction increased binding potential (BP{sub ND}) in the striatum and midbrain by 14 and 18% in the [{sup 18}F]FE-PE2I study, and striatal BP{sub ND} by 6 and 10% in the [{sup 11}C]MNPA and [{sup 11}C]raclopride studies. PSF reconstruction improved quantification by increasing the RC and thus reducing the partial volume effect. This method provides improved conditions for PET quantification in clinical studies with the HRRT system, particularly when targeting receptor populations in small brain structures. (orig.)

  6. Health-related quality of life after segmental resection of the lateral mandible: Free fibula flap versus plate reconstruction.

    Science.gov (United States)

    van Gemert, Johannes; Holtslag, Irene; van der Bilt, Andries; Merkx, Matthias; Koole, Ron; Van Cann, Ellen

    2015-06-01

    Segmental resection of the mandible causes functional, aesthetic and social problems affecting health-related quality of life (HRQoL). It is often assumed that reconstruction with composite free flaps guarantees better function and aesthetics than bridging the defect with reconstruction plates. Using the European Organization for Research and Treatment of Cancer questionnaires (EORTC QLQ-C30 version 3.0 and EORTC QLQ-H&N35), we compared HRQoL in patients who received free fibula flaps versus reconstruction plates after segmental resection of the lateral mandible. Thirty-seven completed questionnaires (18 fibula reconstructions and 19 patients with reconstruction plates) were available. Reconstruction with a free fibula flap did not provide clear additional benefit to bridging the defect with a reconstruction plate after segmental resection of the lateral mandible. In particular aspects known to have the most impact on HRQoL like swallowing, speech and chewing were not influenced by the type of reconstruction. Reconstruction of segmental defects of the lateral mandible with free fibula flap and reconstruction plate resulted in comparable HRQoL. If dental rehabilitation by means of dental implants is not anticipated in the fibula, then plate reconstruction with adequate soft tissue remains a suitable technique for the reconstruction of segmental defects of the lateral mandible. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  7. Quality improvement and emerging global health priorities

    Science.gov (United States)

    Mensah Abrampah, Nana; Syed, Shamsuzzoha Babar; Hirschhorn, Lisa R; Nambiar, Bejoy; Iqbal, Usman; Garcia-Elorrio, Ezequiel; Chattu, Vijay Kumar; Devnani, Mahesh; Kelley, Edward

    2018-01-01

    Abstract Quality improvement approaches can strengthen action on a range of global health priorities. Quality improvement efforts are uniquely placed to reorient care delivery systems towards integrated people-centred health services and strengthen health systems to achieve Universal Health Coverage (UHC). This article makes the case for addressing shortfalls of previous agendas by articulating the critical role of quality improvement in the Sustainable Development Goal era. Quality improvement can stimulate convergence between health security and health systems; address global health security priorities through participatory quality improvement approaches; and improve health outcomes at all levels of the health system. Entry points for action include the linkage with antimicrobial resistance and the contentious issue of the health of migrants. The work required includes focussed attention on the continuum of national quality policy formulation, implementation and learning; alongside strengthening the measurement-improvement linkage. Quality improvement plays a key role in strengthening health systems to achieve UHC. PMID:29873793

  8. How far can the radiation dose be lowered in head CT with iterative reconstruction? Analysis of imaging quality and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tung-Hsin; Sun, Jing-Yi [National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China); Hung, Sheng-Che; Lin, Chung-Jung; Chiu, Chen Fen; Liu, Min-Jsuan; Teng, Michael Mu Huo; Guo, Wan-Yuo; Chang, Cheng-Yen [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); National Yang-Ming University, School of Medicine, Taipei (China); Lin, Chung-Hsien [National Taiwan University, Graduate Institute of Epidemiology and Preventive Medicine, Taipei (China)

    2013-09-15

    To evaluate the imaging quality of head CT at lowered radiation dose by combining filtered back projection (FBP) and iterative reconstruction (IR) algorithms. Experimental group A (n = 66) underwent CT with 43 % tube current reduction, and group B (n = 58) received an equivalent reduced dose by lowering the tube voltage. An age- and sex-matched control group (n = 72) receiving the conventional radiation dose was retrospectively collected. Imaging for the control group was reconstructed by FBP only, while images for groups A and B were reconstructed by FBP and IR. The signal-to-noise ratios (SNRs), contrast-to-noise ratios (CNRs), sharpness, number of infarcts and severity of subcortical arteriosclerotic encephalopathy (SAE) were compared to assess imaging quality and diagnostic accuracy. There were no significant differences in SNRs and CNRs between group A and the control group. There were significantly decreased SNRs and increased CNRs in group B. Image sharpness decreased in both groups. Correlations between detected infarcts and severity of SAE across FBP and IR were high (r = 0.73-0.93). Head diameter was the only significant factor inversely correlated with infratentorial imaging quality. Head CT with 43 % reduced tube current reconstructed by IR provides diagnostic imaging quality for outpatient management. (orig.)

  9. Embryo Aggregation in Pig Improves Cloning Efficiency and Embryo Quality.

    Science.gov (United States)

    Buemo, Carla Paola; Gambini, Andrés; Moro, Lucia Natalia; Hiriart, María Inés; Fernández-Martín, Rafael; Collas, Philippe; Salamone, Daniel Felipe

    2016-01-01

    In this study, we analyzed the effects of the cloned embryo aggregation on in vitro embryo development and embryo quality by measuring blastocyst diameter and cell number, DNA fragmentation levels and the expression of genes associated with pluripotency, apoptosis, trophoblast and DNA methylation in the porcine. Zona-free reconstructed cloned embryos were cultured in the well of the well system, placing one (1x non aggregated group) or three (3x group) embryos per microwell. Our results showed that aggregation of three embryos increased blastocyst formation rate and blastocyst diameter of cloned pig embryos. DNA fragmentation levels in 3x aggregated cloned blastocysts were significantly decreased compared to 1x blastocysts. Levels of Oct4, Klf4, Igf2, Bax and Dnmt 1 transcripts were significantly higher in aggregated embryos, whereas Nanog levels were not affected. Transcripts of Cdx2 and Bcl-xl were essentially non-detectable. Our study suggests that embryo aggregation in the porcine may be beneficial for cloned embryo development and embryo quality, through a reduction in apoptotic levels and an improvement in cell reprogramming.

  10. IMPROVING CORRELATION FUNCTION FITTING WITH RIDGE REGRESSION: APPLICATION TO CROSS-CORRELATION RECONSTRUCTION

    International Nuclear Information System (INIS)

    Matthews, Daniel J.; Newman, Jeffrey A.

    2012-01-01

    Cross-correlation techniques provide a promising avenue for calibrating photometric redshifts and determining redshift distributions using spectroscopy which is systematically incomplete (e.g., current deep spectroscopic surveys fail to obtain secure redshifts for 30%-50% or more of the galaxies targeted). In this paper, we improve on the redshift distribution reconstruction methods from our previous work by incorporating full covariance information into our correlation function fits. Correlation function measurements are strongly covariant between angular or spatial bins, and accounting for this in fitting can yield substantial reduction in errors. However, frequently the covariance matrices used in these calculations are determined from a relatively small set (dozens rather than hundreds) of subsamples or mock catalogs, resulting in noisy covariance matrices whose inversion is ill-conditioned and numerically unstable. We present here a method of conditioning the covariance matrix known as ridge regression which results in a more well behaved inversion than other techniques common in large-scale structure studies. We demonstrate that ridge regression significantly improves the determination of correlation function parameters. We then apply these improved techniques to the problem of reconstructing redshift distributions. By incorporating full covariance information, applying ridge regression, and changing the weighting of fields in obtaining average correlation functions, we obtain reductions in the mean redshift distribution reconstruction error of as much as ∼40% compared to previous methods. We provide a description of POWERFIT, an IDL code for performing power-law fits to correlation functions with ridge regression conditioning that we are making publicly available.

  11. How to Begin a Quality Improvement Project.

    Science.gov (United States)

    Silver, Samuel A; Harel, Ziv; McQuillan, Rory; Weizman, Adam V; Thomas, Alison; Chertow, Glenn M; Nesrallah, Gihad; Bell, Chaim M; Chan, Christopher T

    2016-05-06

    Quality improvement involves a combined effort among health care staff and stakeholders to diagnose and treat problems in the health care system. However, health care professionals often lack training in quality improvement methods, which makes it challenging to participate in improvement efforts. This article familiarizes health care professionals with how to begin a quality improvement project. The initial steps involve forming an improvement team that possesses expertise in the quality of care problem, leadership, and change management. Stakeholder mapping and analysis are useful tools at this stage, and these are reviewed to help identify individuals who might have a vested interest in the project. Physician engagement is a particularly important component of project success, and the knowledge that patients/caregivers can offer as members of a quality improvement team should not be overlooked. After a team is formed, an improvement framework helps to organize the scientific process of system change. Common quality improvement frameworks include Six Sigma, Lean, and the Model for Improvement. These models are contrasted, with a focus on the Model for Improvement, because it is widely used and applicable to a variety of quality of care problems without advanced training. It involves three steps: setting aims to focus improvement, choosing a balanced set of measures to determine if improvement occurs, and testing new ideas to change the current process. These new ideas are evaluated using Plan-Do-Study-Act cycles, where knowledge is gained by testing changes and reflecting on their effect. To show the real world utility of the quality improvement methods discussed, they are applied to a hypothetical quality improvement initiative that aims to promote home dialysis (home hemodialysis and peritoneal dialysis). This provides an example that kidney health care professionals can use to begin their own quality improvement projects. Copyright © 2016 by the American

  12. IMPROVING CONCEPTUAL DESIGN QUALITY

    DEFF Research Database (Denmark)

    Bush, Stuart; Robotham, Antony John

    1999-01-01

    designer to identify clear targets for design improvement and to measure the effectiveness of any new solution, whilst attention to QFD ensures customer requirements are still being satisfied.Often, SME's are not aware of many of the best design practices and so are not able to meet the demand......This paper will consider how Quality Function Deployment (QFD) and Design for Manufacture and Assembly (DFMA) processes can be used to improve the design quality of products at the concept stage. We appreciate that both QFD and DFMA are techniques that have been used for some time by mature product...... quality is maintained in design project work. The projects described have been carried out with products manufactured by small to medium sized enterprises (SME's), where we have found significant opportunities for product improvement. The quantitative nature of DFMA analysis results allows the novice...

  13. Mid- and long-term runoff predictions by an improved phase-space reconstruction model

    International Nuclear Information System (INIS)

    Hong, Mei; Wang, Dong; Wang, Yuankun; Zeng, Xiankui; Ge, Shanshan; Yan, Hengqian; Singh, Vijay P.

    2016-01-01

    In recent years, the phase-space reconstruction method has usually been used for mid- and long-term runoff predictions. However, the traditional phase-space reconstruction method is still needs to be improved. Using the genetic algorithm to improve the phase-space reconstruction method, a new nonlinear model of monthly runoff is constructed. The new model does not rely heavily on embedding dimensions. Recognizing that the rainfall–runoff process is complex, affected by a number of factors, more variables (e.g. temperature and rainfall) are incorporated in the model. In order to detect the possible presence of chaos in the runoff dynamics, chaotic characteristics of the model are also analyzed, which shows the model can represent the nonlinear and chaotic characteristics of the runoff. The model is tested for its forecasting performance in four types of experiments using data from six hydrological stations on the Yellow River and the Yangtze River. Results show that the medium-and long-term runoff is satisfactorily forecasted at the hydrological stations. Not only is the forecasting trend accurate, but also the mean absolute percentage error is no more than 15%. Moreover, the forecast results of wet years and dry years are both good, which means that the improved model can overcome the traditional ‘‘wet years and dry years predictability barrier,’’ to some extent. The model forecasts for different regions are all good, showing the universality of the approach. Compared with selected conceptual and empirical methods, the model exhibits greater reliability and stability in the long-term runoff prediction. Our study provides a new thinking for research on the association between the monthly runoff and other hydrological factors, and also provides a new method for the prediction of the monthly runoff. - Highlights: • The improved phase-space reconstruction model of monthly runoff is established. • Two variables (temperature and rainfall) are incorporated

  14. Mid- and long-term runoff predictions by an improved phase-space reconstruction model

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Mei [Research Center of Ocean Environment Numerical Simulation, Institute of Meteorology and oceanography, PLA University of Science and Technology, Nanjing (China); Wang, Dong, E-mail: wangdong@nju.edu.cn [Key Laboratory of Surficial Geochemistry, Ministry of Education, Department of Hydrosciences, School of Earth Sciences and Engineering, Collaborative Innovation Center of South China Sea Studies, State Key Laboratory of Pollution Control and Resource Reuse, Nanjing University, Nanjing 210093 (China); Wang, Yuankun; Zeng, Xiankui [Key Laboratory of Surficial Geochemistry, Ministry of Education, Department of Hydrosciences, School of Earth Sciences and Engineering, Collaborative Innovation Center of South China Sea Studies, State Key Laboratory of Pollution Control and Resource Reuse, Nanjing University, Nanjing 210093 (China); Ge, Shanshan; Yan, Hengqian [Research Center of Ocean Environment Numerical Simulation, Institute of Meteorology and oceanography, PLA University of Science and Technology, Nanjing (China); Singh, Vijay P. [Department of Biological and Agricultural Engineering Zachry Department of Civil Engineering, Texas A & M University, College Station, TX 77843 (United States)

    2016-07-15

    In recent years, the phase-space reconstruction method has usually been used for mid- and long-term runoff predictions. However, the traditional phase-space reconstruction method is still needs to be improved. Using the genetic algorithm to improve the phase-space reconstruction method, a new nonlinear model of monthly runoff is constructed. The new model does not rely heavily on embedding dimensions. Recognizing that the rainfall–runoff process is complex, affected by a number of factors, more variables (e.g. temperature and rainfall) are incorporated in the model. In order to detect the possible presence of chaos in the runoff dynamics, chaotic characteristics of the model are also analyzed, which shows the model can represent the nonlinear and chaotic characteristics of the runoff. The model is tested for its forecasting performance in four types of experiments using data from six hydrological stations on the Yellow River and the Yangtze River. Results show that the medium-and long-term runoff is satisfactorily forecasted at the hydrological stations. Not only is the forecasting trend accurate, but also the mean absolute percentage error is no more than 15%. Moreover, the forecast results of wet years and dry years are both good, which means that the improved model can overcome the traditional ‘‘wet years and dry years predictability barrier,’’ to some extent. The model forecasts for different regions are all good, showing the universality of the approach. Compared with selected conceptual and empirical methods, the model exhibits greater reliability and stability in the long-term runoff prediction. Our study provides a new thinking for research on the association between the monthly runoff and other hydrological factors, and also provides a new method for the prediction of the monthly runoff. - Highlights: • The improved phase-space reconstruction model of monthly runoff is established. • Two variables (temperature and rainfall) are incorporated

  15. Wavelet processing and digital interferometric contrast to improve reconstructions from X-ray Gabor holograms.

    Science.gov (United States)

    Aguilar, Juan C; Misawa, Masaki; Matsuda, Kiyofumi; Suzuki, Yoshio; Takeuchi, Akihisa; Yasumoto, Masato

    2018-05-01

    In this work, the application of an undecimated wavelet transformation together with digital interferometric contrast to improve the resulting reconstructions in a digital hard X-ray Gabor holographic microscope is shown. Specifically, the starlet transform is used together with digital Zernike contrast. With this contrast, the results show that only a small set of scales from the hologram are, in effect, useful, and it is possible to enhance the details of the reconstruction.

  16. The National Surgical Quality Improvement Program 30-Day Challenge: Microsurgical Breast Reconstruction Outcomes Reporting Reliability

    Directory of Open Access Journals (Sweden)

    Austin D. Chen

    2018-03-01

    Conclusion:. For immediate, free-tissue breast reconstruction, the ACS-NSQIP may be reliable for monitoring and comparing SSI, WD, URO, and URA rates. However, clinicians may find it useful to understand limitations of the ACS-NSQIP for complications and risk factors, as it may underreport complications occurring beyond 30 days.

  17. Continuous quality improvement

    NARCIS (Netherlands)

    Rohlin, Madeleine; Schaub, Rob M.H.; Holbrook, Peter; Leibur, Edvitar; Lévy, Gérard; Roubalikova, Lenka; Nilner, Maria; Roger-Leroi, Valerie; Danner, Gunter; Iseri, Haluk; Feldman, Cecile

    2002-01-01

    Versch. in: Eur J Dent Educ; 6 (Suppl. 3): 67–77 Continuous quality improvement (CQI) can be envisaged as a circular process of goal-setting, followed by external and internal evaluations resulting in improvements that can serve as goals for a next cycle. The need for CQI is apparent, because of

  18. Block Compressed Sensing of Images Using Adaptive Granular Reconstruction

    Directory of Open Access Journals (Sweden)

    Ran Li

    2016-01-01

    Full Text Available In the framework of block Compressed Sensing (CS, the reconstruction algorithm based on the Smoothed Projected Landweber (SPL iteration can achieve the better rate-distortion performance with a low computational complexity, especially for using the Principle Components Analysis (PCA to perform the adaptive hard-thresholding shrinkage. However, during learning the PCA matrix, it affects the reconstruction performance of Landweber iteration to neglect the stationary local structural characteristic of image. To solve the above problem, this paper firstly uses the Granular Computing (GrC to decompose an image into several granules depending on the structural features of patches. Then, we perform the PCA to learn the sparse representation basis corresponding to each granule. Finally, the hard-thresholding shrinkage is employed to remove the noises in patches. The patches in granule have the stationary local structural characteristic, so that our method can effectively improve the performance of hard-thresholding shrinkage. Experimental results indicate that the reconstructed image by the proposed algorithm has better objective quality when compared with several traditional ones. The edge and texture details in the reconstructed image are better preserved, which guarantees the better visual quality. Besides, our method has still a low computational complexity of reconstruction.

  19. GRAPPA reconstructed wave-CAIPI MP-RAGE at 7 Tesla.

    Science.gov (United States)

    Schwarz, Jolanda M; Pracht, Eberhard D; Brenner, Daniel; Reuter, Martin; Stöcker, Tony

    2018-04-16

    The aim of this project was to develop a GRAPPA-based reconstruction for wave-CAIPI data. Wave-CAIPI fully exploits the 3D coil sensitivity variations by combining corkscrew k-space trajectories with CAIPIRINHA sampling. It reduces artifacts and limits reconstruction induced spatially varying noise enhancement. The GRAPPA-based wave-CAIPI method is robust and does not depend on the accuracy of coil sensitivity estimations. We developed a GRAPPA-based, noniterative wave-CAIPI reconstruction algorithm utilizing multiple GRAPPA kernels. For data acquisition, we implemented a fast 3D magnetization-prepared rapid gradient-echo wave-CAIPI sequence tailored for ultra-high field application. The imaging results were evaluated by comparing the g-factor and the root mean square error to Cartesian CAIPIRINHA acquisitions. Additionally, to assess the performance of subcortical segmentations (calculated by FreeSurfer), the data were analyzed across five subjects. Sixteen-fold accelerated whole brain magnetization-prepared rapid gradient-echo data (1 mm isotropic resolution) were acquired in 40 seconds at 7T. A clear improvement in image quality compared to Cartesian CAIPIRINHA sampling was observed. For the chosen imaging protocol, the results of 16-fold accelerated wave-CAIPI acquisitions were comparable to results of 12-fold accelerated Cartesian CAIPIRINHA. In comparison to the originally proposed SENSitivity Encoding reconstruction of Wave-CAIPI data, the GRAPPA approach provided similar image quality. High-quality, wave-CAIPI magnetization-prepared rapid gradient-echo images can be reconstructed by means of a GRAPPA-based reconstruction algorithm. Even for high acceleration factors, the noniterative reconstruction is robust and does not require coil sensitivity estimations. By altering the aliasing pattern, ultra-fast whole-brain structural imaging becomes feasible. © 2018 International Society for Magnetic Resonance in Medicine.

  20. Measurement of Outcomes of Upper Limb Reconstructive Surgery for Tetraplegia

    NARCIS (Netherlands)

    Sinnott, K. Anne; Dunn, Jennifer A.; Wangdell, Johanna; Johanson, M. Elise; Hall, Andrew S.; Post, Marcel W.

    Reconstructive arm/hand surgery for tetraplegia is performed to improve arm/hand function and therefore personal well-being for individuals who accept such elective surgeries. However, changes at an impairment level do not always translate into functional or quality of life changes. Therefore,

  1. Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: comparison of multisegment and halfscan reconstruction approaches

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc; Teige, Florian; Hamm, Bernd [Charite - Universitaetsmedizin Berlin, Humboldt-Universitaet zu Berlin, Department of Radiology, Chariteplatz 1, P.O. Box 10098, Berlin (Germany); Laule, Michael [Department of Cardiology, Charite, Berlin (Germany)

    2007-11-15

    The lower the heart rate the better image quality in multislice computed tomography (MSCT) coronary angiography. We prospectively assessed the influence of heart rate on per-patient diagnostic accuracy and image quality of MSCT coronary angiography and compared adaptive multisegment and standard halfscan reconstruction. A consecutive cohort of 126 patients scheduled to undergo conventional coronary angiography was examined with 16-slice CT. For all heart rate groups, per-patient diagnostic accuracy was significantly higher for multisegment than halfscan reconstruction with values of 95 vs. 79% (p < 0.05, <65 bpm, 38 patients), 85 vs. 66% (p < 0.05, 65-74 bpm, 47 patients), and 78% vs. 41% (p < 0.001, >74 bpm, 41 patients). Differences in diagnostic accuracy between adjacent heart rate groups were only significant for halfscan reconstruction for the comparison between the 65-74 and >74 bpm group (p < 0.05). The vessel lengths free of motion artifacts were significantly longer with multisegment reconstruction in all heart rate groups and for all coronary arteries (p < 0.005). For noninvasive MSCT coronary angiography, both per-patient diagnostic accuracy and image quality decline with increasing heart rate, and multisegment reconstruction at high heart rates yields similar results as standard halfscan reconstruction at low heart rates. (orig.)

  2. Does competition improve health care quality?

    Science.gov (United States)

    Scanlon, Dennis P; Swaminathan, Shailender; Lee, Woolton; Chernew, Michael

    2008-12-01

    To identify the effect of competition on health maintenance organizations' (HMOs) quality measures. Longitudinal analysis of a 5-year panel of the Healthcare Effectiveness Data and Information Set (HEDIS) and Consumer Assessment of Health Plans Survey(R) (CAHPS) data (calendar years 1998-2002). All plans submitting data to the National Committee for Quality Assurance (NCQA) were included regardless of their decision to allow NCQA to disclose their results publicly. NCQA, Interstudy, the Area Resource File, and the Bureau of Labor Statistics. Fixed-effects models were estimated that relate HMO competition to HMO quality controlling for an unmeasured, time-invariant plan, and market traits. Results are compared with estimates from models reliant on cross-sectional variation. Estimates suggest that plan quality does not improve with increased levels of HMO competition (as measured by either the Herfindahl index or the number of HMOs). Similarly, increased HMO penetration is generally not associated with improved quality. Cross-sectional models tend to suggest an inverse relationship between competition and quality. The strategies that promote competition among HMOs in the current market setting may not lead to improved HMO quality. It is possible that price competition dominates, with purchasers and consumers preferring lower premiums at the expense of improved quality, as measured by HEDIS and CAHPS. It is also possible that the fragmentation associated with competition hinders quality improvement.

  3. INFLUENCE OF DIFFERENT LEVELS OF SPORTS ACTIVITIES ON THE QUALITY OF LIFE AFTER THE RECONSTRUCTION OF ANTERIOR CRUCIATE LIGAMENT.

    Science.gov (United States)

    Ninković, Srđan; Avramov, Snežana; Harhaji, Vladimir; Obradović, Mirko; Vranješ, Miodrag; Milankov, Miroslav

    2015-01-01

    The goal of this study was to examine the nature and presence of influence of different levels of sports activity on the life quality of the patients a year after the reconstruction of anterior cruciate ligament. The study included 185 patients operated at the Department of Orthopedic Surgery and Traumatology of the Clinical Centre of Vojvodina, who were followed for twelve months. Data were collected using the modified Knee Injury and Osteoarthritis Outcome Score questionnaire which included the Lysholm scale. This study included 146 male and 39 female subjects. The reconstruction of anterior cruciate ligament was equally successful in both gender groups. In relation to different types of sports activity, there were no differences in the overall life quality measured by the questionnaire and its subscales, regardless of the level (professional or recreational). However, regarding the level of sports activities, there were differences among the subjects engaged in sports activities at the national level as compared with those going in for sports activities at the recreational level, and particularly in comparison with physically inactive population. A significant correlation was not found by examining the aforementioned relationship between sports activities. This study has shown that the overall life quality a year after the reconstruction of the anterior cruciate ligament does not differ in relation to either the gender of the subjects or the type of sports activity, while the level of sports activity does have some influence on the quality of life. Professional athletes have proved to train significantly more intensively after this reconstruction than those going in for sports recreationally.

  4. Evaluation of the image quality in digital breast tomosynthesis (DBT) employed with a compressed-sensing (CS)-based reconstruction algorithm by using the mammographic accreditation phantom

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yeonok; Cho, Heemoon; Je, Uikyu; Cho, Hyosung, E-mail: hscho1@yonsei.ac.kr; Park, Chulkyu; Lim, Hyunwoo; Kim, Kyuseok; Kim, Guna; Park, Soyoung; Woo, Taeho; Choi, Sungil

    2015-12-21

    In this work, we have developed a prototype digital breast tomosynthesis (DBT) system which mainly consists of an x-ray generator (28 kV{sub p}, 7 mA s), a CMOS-type flat-panel detector (70-μm pixel size, 230.5×339 mm{sup 2} active area), and a rotational arm to move the x-ray generator in an arc. We employed a compressed-sensing (CS)-based reconstruction algorithm, rather than a common filtered-backprojection (FBP) one, for more accurate DBT reconstruction. Here the CS is a state-of-the-art mathematical theory for solving the inverse problems, which exploits the sparsity of the image with substantially high accuracy. We evaluated the reconstruction quality in terms of the detectability, the contrast-to-noise ratio (CNR), and the slice-sensitive profile (SSP) by using the mammographic accreditation phantom (Model 015, CIRS Inc.) and compared it to the FBP-based quality. The CS-based algorithm yielded much better image quality, preserving superior image homogeneity, edge sharpening, and cross-plane resolution, compared to the FBP-based one. - Highlights: • A prototype digital breast tomosynthesis (DBT) system is developed. • Compressed-sensing (CS) based reconstruction framework is employed. • We reconstructed high-quality DBT images by using the proposed reconstruction framework.

  5. CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction.

    Science.gov (United States)

    Ichikawa, Yasutaka; Kitagawa, Kakuya; Nagasawa, Naoki; Murashima, Shuichi; Sakuma, Hajime

    2013-08-09

    The recently developed model-based iterative reconstruction (MBIR) enables significant reduction of image noise and artifacts, compared with adaptive statistical iterative reconstruction (ASIR) and filtered back projection (FBP). The purpose of this study was to evaluate lesion detectability of low-dose chest computed tomography (CT) with MBIR in comparison with ASIR and FBP. Chest CT was acquired with 64-slice CT (Discovery CT750HD) with standard-dose (5.7 ± 2.3 mSv) and low-dose (1.6 ± 0.8 mSv) conditions in 55 patients (aged 72 ± 7 years) who were suspected of lung disease on chest radiograms. Low-dose CT images were reconstructed with MBIR, ASIR 50% and FBP, and standard-dose CT images were reconstructed with FBP, using a reconstructed slice thickness of 0.625 mm. Two observers evaluated the image quality of abnormal lung and mediastinal structures on a 5-point scale (Score 5 = excellent and score 1 = non-diagnostic). The objective image noise was also measured as the standard deviation of CT intensity in the descending aorta. The image quality score of enlarged mediastinal lymph nodes on low-dose MBIR CT (4.7 ± 0.5) was significantly improved in comparison with low-dose FBP and ASIR CT (3.0 ± 0.5, p = 0.004; 4.0 ± 0.5, p = 0.02, respectively), and was nearly identical to the score of standard-dose FBP image (4.8 ± 0.4, p = 0.66). Concerning decreased lung attenuation (bulla, emphysema, or cyst), the image quality score on low-dose MBIR CT (4.9 ± 0.2) was slightly better compared to low-dose FBP and ASIR CT (4.5 ± 0.6, p = 0.01; 4.6 ± 0.5, p = 0.01, respectively). There were no significant differences in image quality scores of visualization of consolidation or mass, ground-glass attenuation, or reticular opacity among low- and standard-dose CT series. Image noise with low-dose MBIR CT (11.6 ± 1.0 Hounsfield units (HU)) were significantly lower than with low-dose ASIR (21.1 ± 2.6 HU, p standard-dose FBP CT (16.6 ± 2.3 HU, p 70%, MBIR can provide

  6. Reconstruction design before tumour resection: A new concept of through-and-through cheek defect reconstruction.

    Science.gov (United States)

    Gong, Zhao-Jian; Ren, Zhen-Hu; Wang, Kai; Tan, Hong-Yu; Zhang, Sheng; Wu, Han-Jiang

    2017-11-01

    To explore a new method of reconstruction of through-and-through cheek defects and to evaluate this method's efficacy and patient prognosis. This retrospective study included 70 patients who underwent reconstruction of through-and-through cheek defects. The surgical approach, design of facial skin incisions, selection and design of flaps, postoperative quality of life and prognosis of patients were recorded and reported. Postoperative quality of life gradually increased over time, and the mean scores of University of Washington Quality of Life (UW-QOL) Questionnaire was more than 80 at 1-year postoperatively. The appearance, oral competence, chewing, swallowing, speech and other oral functions were well recovered in about 90% of patients at 1-year postoperatively. This new idea of reconstruction before tumour resection, brings the effect of plastic and reconstructive surgery to a new height. Copyright © 2017. Published by Elsevier Ltd.

  7. An ART iterative reconstruction algorithm for computed tomography of diffraction enhanced imaging

    International Nuclear Information System (INIS)

    Wang Zhentian; Zhang Li; Huang Zhifeng; Kang Kejun; Chen Zhiqiang; Fang Qiaoguang; Zhu Peiping

    2009-01-01

    X-ray diffraction enhanced imaging (DEI) has extremely high sensitivity for weakly absorbing low-Z samples in medical and biological fields. In this paper, we propose an Algebra Reconstruction Technique (ART) iterative reconstruction algorithm for computed tomography of diffraction enhanced imaging (DEI-CT). An Ordered Subsets (OS) technique is used to accelerate the ART reconstruction. Few-view reconstruction is also studied, and a partial differential equation (PDE) type filter which has the ability of edge-preserving and denoising is used to improve the image quality and eliminate the artifacts. The proposed algorithm is validated with both the numerical simulations and the experiment at the Beijing synchrotron radiation facility (BSRF). (authors)

  8. Vertex Reconstruction at STAR: Overview and Performance Evaluation

    Science.gov (United States)

    Smirnov, D.; Lauret, J.; Perevoztchikov, V.; Van Buren, G.; Webb, J.

    2017-10-01

    The STAR experiment at the Relativistic Heavy Ion Collider (RHIC) has a rich physics program ranging from studies of the Quark Gluon Plasma to the exploration of the spin structure of the proton. Many measurements carried out by the STAR collaboration rely on the efficient reconstruction and precise knowledge of the position of the primary-interaction vertex. Throughout the years two main vertex finders have been predominantly utilized in event reconstruction by the experiment: MinutVF and PPV with their application domains focusing on heavy ion and proton-proton events respectively. In this work we give a brief overview and discuss recent improvements to the vertex finding algorithms implemented in the STAR software library. In our studies we focus on the finding efficiency and the quality of the reconstructed primary vertex. We examine the effect of an additional constraint, imposed by an independent measurement of the beam line position, when it is applied during the fit. We evaluate the significance of the improved primary vertex resolution on identification of the secondary decay vertices occurring inside the beam pipe. Finally, we present a method and its software implementation developed to measure the performance of the primary vertex reconstruction algorithms.

  9. Moving up the Ladder: How Do States Deliver Quality Improvement Supports within Their Quality Rating and Improvement Systems? Brief

    Science.gov (United States)

    Holod, Aleksandra; Faria, Ann-Marie; Weinberg, Emily; Howard, Eboni

    2015-01-01

    As national attention has increasingly focused on the potential for high-quality early childhood education (ECE) to improve children's school readiness, states have developed quality rating and improvement systems (QRISs) to document the quality of ECE programs, support systematic quality improvement, and provide clear information to families…

  10. Using Quality Tools and Methodologies to Improve a Hospital's Quality Position.

    Science.gov (United States)

    Branco, Daniel; Wicks, Angela M; Visich, John K

    2017-01-01

    The authors identify the quality tools and methodologies most frequently used by quality-positioned hospitals versus nonquality hospitals. Northeastern U.S. hospitals in both groups received a brief, 12-question survey. The authors found that 93.75% of the quality hospitals and 81.25% of the nonquality hospitals used some form of process improvement methodologies. However, there were significant differences between the groups regarding the impact of quality improvement initiatives on patients. The findings indicate that in quality hospitals the use of quality improvement initiatives had a significantly greater positive impact on patient satisfaction and patient outcomes when compared to nonquality hospitals.

  11. The impact of leadership qualities on quality management improvement

    Directory of Open Access Journals (Sweden)

    Ph. D. Radoslaw Wolniak

    2011-05-01

    Full Text Available Currently, the importance of leadership is considered more and more often in quality management. The need of an appropriate leader has been already emphasized in ISO 9000 standards, in TQM philosophy as well as in different models of improvement which are used in the methodologies of prizing quality. Yet, it is in the concept of TQL where the attitude based on the need of leadership in an organization has achieved its best-developed, full shape. On the basis of the conducted studies, the following publication presents the analysis of the dependence between leadership qualities of managers and the improvement of quality management. There has been an attempt to define the qualities, which a manager being responsible for quality management, should have.

  12. The impact of leadership qualities on quality management improvement

    Directory of Open Access Journals (Sweden)

    Radoslaw Wolniak

    2011-12-01

    Full Text Available Currently, the importance of leadership is considered more and more often in quality management. The need of an appropriate leader has been already emphasized in ISO 9000 standards, in TQM philosophy as well as in different models of improvement which are used in the methodologies of prizing quality. Yet, it is in the concept of TQL where the attitude based on the need of leadership in an organization has achieved its best-developed, full shape. On the basis of the conducted studies, the following publication presents the analysis of the dependence between leadership qualities of managers and the improvement of quality management. There has been an attempt to define the qualities, which a manager being responsible for quality management, should have.

  13. Research on reconstruction of steel tube section from few projections

    International Nuclear Information System (INIS)

    Peng Shuaijun; Wu Haifeng; Wang Kai

    2007-01-01

    Most parameters of steel tube can be acquired from CT image of the section so as to evaluate its quality. But large numbers of projections are needed in order to reconstruct the section image, so the collection and calculation of the projections consume lots of time. In order to solve the problem, reconstruction algorithms of steel tube from few projections are researched and the results are validated with simulation data in the paper. Three iterative algorithms, ART, MAP and OSEM, are attempted to reconstruct the section of steel tube by using the simulation model. Considering the prior information distributing of steel tube, we improve the algorithms and get better reconstruction images. The results of simulation experiment indicate that ART, MAP and OSEM can reconstruct accurate section images of steel tube from less than 20 projections and approximate images from 10 projections. (authors)

  14. Can state-of-the-art HVS-based objective image quality criteria be used for image reconstruction techniques based on ROI analysis?

    Science.gov (United States)

    Dostal, P.; Krasula, L.; Klima, M.

    2012-06-01

    Various image processing techniques in multimedia technology are optimized using visual attention feature of the human visual system. Spatial non-uniformity causes that different locations in an image are of different importance in terms of perception of the image. In other words, the perceived image quality depends mainly on the quality of important locations known as regions of interest. The performance of such techniques is measured by subjective evaluation or objective image quality criteria. Many state-of-the-art objective metrics are based on HVS properties; SSIM, MS-SSIM based on image structural information, VIF based on the information that human brain can ideally gain from the reference image or FSIM utilizing the low-level features to assign the different importance to each location in the image. But still none of these objective metrics utilize the analysis of regions of interest. We solve the question if these objective metrics can be used for effective evaluation of images reconstructed by processing techniques based on ROI analysis utilizing high-level features. In this paper authors show that the state-of-the-art objective metrics do not correlate well with subjective evaluation while the demosaicing based on ROI analysis is used for reconstruction. The ROI were computed from "ground truth" visual attention data. The algorithm combining two known demosaicing techniques on the basis of ROI location is proposed to reconstruct the ROI in fine quality while the rest of image is reconstructed with low quality. The color image reconstructed by this ROI approach was compared with selected demosaicing techniques by objective criteria and subjective testing. The qualitative comparison of the objective and subjective results indicates that the state-of-the-art objective metrics are still not suitable for evaluation image processing techniques based on ROI analysis and new criteria is demanded.

  15. Homotopic non-local regularized reconstruction from sparse positron emission tomography measurements

    International Nuclear Information System (INIS)

    Wong, Alexander; Liu, Chenyi; Wang, Xiao Yu; Fieguth, Paul; Bie, Hongxia

    2015-01-01

    Positron emission tomography scanners collect measurements of a patient’s in vivo radiotracer distribution. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule, and the tomograms must be reconstructed from projections. The reconstruction of tomograms from the acquired PET data is an inverse problem that requires regularization. The use of tightly packed discrete detector rings, although improves signal-to-noise ratio, are often associated with high costs of positron emission tomography systems. Thus a sparse reconstruction, which would be capable of overcoming the noise effect while allowing for a reduced number of detectors, would have a great deal to offer. In this study, we introduce and investigate the potential of a homotopic non-local regularization reconstruction framework for effectively reconstructing positron emission tomograms from such sparse measurements. Results obtained using the proposed approach are compared with traditional filtered back-projection as well as expectation maximization reconstruction with total variation regularization. A new reconstruction method was developed for the purpose of improving the quality of positron emission tomography reconstruction from sparse measurements. We illustrate that promising reconstruction performance can be achieved for the proposed approach even at low sampling fractions, which allows for the use of significantly fewer detectors and have the potential to reduce scanner costs

  16. Achieving Improvement Through Nursing Home Quality Measurement

    OpenAIRE

    Harris, Yael; Clauser, Steven B.

    2002-01-01

    CMS has initiated the Nursing Home Quality Initiative (NHQI) to improve the quality of nursing home care. Central to the NHQI is the public reporting of nursing home quality measures that serve as the basis for the Initiative's communication and quality improvement program. This article provides an overview of the NHQI, focusing on the role of nursing home quality measures in achieving improvements in nursing home care. We also describe the evolution of quality measurement in nursing homes, a...

  17. Improved quantitative 90 Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling.

    Science.gov (United States)

    Dewaraja, Yuni K; Chun, Se Young; Srinivasa, Ravi N; Kaza, Ravi K; Cuneo, Kyle C; Majdalany, Bill S; Novelli, Paula M; Ljungberg, Michael; Fessler, Jeffrey A

    2017-12-01

    In 90 Y microsphere radioembolization (RE), accurate post-therapy imaging-based dosimetry is important for establishing absorbed dose versus outcome relationships for developing future treatment planning strategies. Additionally, accurately assessing microsphere distributions is important because of concerns for unexpected activity deposition outside the liver. Quantitative 90 Y imaging by either SPECT or PET is challenging. In 90 Y SPECT model based methods are necessary for scatter correction because energy window-based methods are not feasible with the continuous bremsstrahlung energy spectrum. The objective of this work was to implement and evaluate a scatter estimation method for accurate 90 Y bremsstrahlung SPECT/CT imaging. Since a fully Monte Carlo (MC) approach to 90 Y SPECT reconstruction is computationally very demanding, in the present study the scatter estimate generated by a MC simulator was combined with an analytical projector in the 3D OS-EM reconstruction model. A single window (105 to 195-keV) was used for both the acquisition and the projector modeling. A liver/lung torso phantom with intrahepatic lesions and low-uptake extrahepatic objects was imaged to evaluate SPECT/CT reconstruction without and with scatter correction. Clinical application was demonstrated by applying the reconstruction approach to five patients treated with RE to determine lesion and normal liver activity concentrations using a (liver) relative calibration. There was convergence of the scatter estimate after just two updates, greatly reducing computational requirements. In the phantom study, compared with reconstruction without scatter correction, with MC scatter modeling there was substantial improvement in activity recovery in intrahepatic lesions (from > 55% to > 86%), normal liver (from 113% to 104%), and lungs (from 227% to 104%) with only a small degradation in noise (13% vs. 17%). Similarly, with scatter modeling contrast improved substantially both visually and in

  18. Photoacoustic image reconstruction via deep learning

    Science.gov (United States)

    Antholzer, Stephan; Haltmeier, Markus; Nuster, Robert; Schwab, Johannes

    2018-02-01

    Applying standard algorithms to sparse data problems in photoacoustic tomography (PAT) yields low-quality images containing severe under-sampling artifacts. To some extent, these artifacts can be reduced by iterative image reconstruction algorithms which allow to include prior knowledge such as smoothness, total variation (TV) or sparsity constraints. These algorithms tend to be time consuming as the forward and adjoint problems have to be solved repeatedly. Further, iterative algorithms have additional drawbacks. For example, the reconstruction quality strongly depends on a-priori model assumptions about the objects to be recovered, which are often not strictly satisfied in practical applications. To overcome these issues, in this paper, we develop direct and efficient reconstruction algorithms based on deep learning. As opposed to iterative algorithms, we apply a convolutional neural network, whose parameters are trained before the reconstruction process based on a set of training data. For actual image reconstruction, a single evaluation of the trained network yields the desired result. Our presented numerical results (using two different network architectures) demonstrate that the proposed deep learning approach reconstructs images with a quality comparable to state of the art iterative reconstruction methods.

  19. Novel Low Cost 3D Surface Model Reconstruction System for Plant Phenotyping

    Directory of Open Access Journals (Sweden)

    Suxing Liu

    2017-09-01

    Full Text Available Accurate high-resolution three-dimensional (3D models are essential for a non-invasive analysis of phenotypic characteristics of plants. Previous limitations in 3D computer vision algorithms have led to a reliance on volumetric methods or expensive hardware to record plant structure. We present an image-based 3D plant reconstruction system that can be achieved by using a single camera and a rotation stand. Our method is based on the structure from motion method, with a SIFT image feature descriptor. In order to improve the quality of the 3D models, we segmented the plant objects based on the PlantCV platform. We also deducted the optimal number of images needed for reconstructing a high-quality model. Experiments showed that an accurate 3D model of the plant was successfully could be reconstructed by our approach. This 3D surface model reconstruction system provides a simple and accurate computational platform for non-destructive, plant phenotyping.

  20. Photoelectron holography with improved image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Matsushita, Tomohiro, E-mail: matusita@spring8.or.j [Japan Synchrotron Radiation Research Institute (JASRI), SPring-8, 1-1-1 Kouto, Sayo-cho, Sayo-gun Hyogo 679-5198 (Japan); Matsui, Fumihiko; Daimon, Hiroshi [Nara Institute of Science and Technology (NAIST), 8916-5 Takayama, Ikoma, Nara 630-0192 (Japan); Hayashi, Kouichi [Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan)

    2010-05-15

    Electron holography is a type of atomic structural analysis, and it has unique features such as element selectivity and the ability to analyze the structure around an impurity in a crystal. In this paper, we introduce the measurement system, electron holograms, a theory for the recording process of an electron hologram, and a theory for the reconstruction algorithm. We describe photoelectron holograms, Auger electron holograms, and the inverse mode of an electron hologram. The reconstruction algorithm, scattering pattern extraction algorithm (SPEA), the SPEA with maximum entropy method (SPEA-MEM), and SPEA-MEM with translational operation are also described.

  1. Photoelectron holography with improved image reconstruction

    International Nuclear Information System (INIS)

    Matsushita, Tomohiro; Matsui, Fumihiko; Daimon, Hiroshi; Hayashi, Kouichi

    2010-01-01

    Electron holography is a type of atomic structural analysis, and it has unique features such as element selectivity and the ability to analyze the structure around an impurity in a crystal. In this paper, we introduce the measurement system, electron holograms, a theory for the recording process of an electron hologram, and a theory for the reconstruction algorithm. We describe photoelectron holograms, Auger electron holograms, and the inverse mode of an electron hologram. The reconstruction algorithm, scattering pattern extraction algorithm (SPEA), the SPEA with maximum entropy method (SPEA-MEM), and SPEA-MEM with translational operation are also described.

  2. Improving the quality of care for patients with hypertension in Moshupa District, Botswana: Quality improvement cycle

    Directory of Open Access Journals (Sweden)

    Cathy Kande

    2014-01-01

    Full Text Available Background: Although there are no prevalence studies on hypertension in Botswana, this condition is thought to be common and the quality of care to be poor.Aim: The aim of this project was to assess and improve the quality of primary care forhypertension.Setting: Moshupa clinic and catchment area, Botswana.Methods: Quality improvement cycle.Results: Two hundred participants were included in the audit. Sixty-eight per cent were women with a mean age of 55 years. In the baseline audit none of the target standards were met. During the re-audit six months later, six out of nine structural target standards, five out of 11 process target standards and one out of two outcome target standards were achieved. Statistically-significant improvement in performance (p < 0.05 was shown in 10 criteria although the target standard was not always met. In the re-audit, the target of achieving blood pressure control (< 140/90 in 70% of patients was achieved.Conclusion: The quality of care for hypertension was suboptimal in our setting. Simple interventions were designed and implemented to improve the quality of care. These interventions led to significant improvement in structural and process criteria. A corresponding significant improvement in the control of blood pressure was also seen.

  3. Practical Approaches to Quality Improvement for Radiologists.

    Science.gov (United States)

    Kelly, Aine Marie; Cronin, Paul

    2015-10-01

    Continuous quality improvement is a fundamental attribute of high-performing health care systems. Quality improvement is an essential component of health care, with the current emphasis on adding value. It is also a regulatory requirement, with reimbursements increasingly being linked to practice performance metrics. Practice quality improvement efforts must be demonstrated for credentialing purposes and for certification of radiologists in practice. Continuous quality improvement must occur for radiologists to remain competitive in an increasingly diverse health care market. This review provides an introduction to the main approaches available to undertake practice quality improvement, which will be useful for busy radiologists. Quality improvement plays multiple roles in radiology services, including ensuring and improving patient safety, providing a framework for implementing and improving processes to increase efficiency and reduce waste, analyzing and depicting performance data, monitoring performance and implementing change, enabling personnel assessment and development through continued education, and optimizing customer service and patient outcomes. The quality improvement approaches and underlying principles overlap, which is not surprising given that they all align with good patient care. The application of these principles to radiology practices not only benefits patients but also enhances practice performance through promotion of teamwork and achievement of goals. © RSNA, 2015.

  4. Low rank alternating direction method of multipliers reconstruction for MR fingerprinting.

    Science.gov (United States)

    Assländer, Jakob; Cloos, Martijn A; Knoll, Florian; Sodickson, Daniel K; Hennig, Jürgen; Lattanzi, Riccardo

    2018-01-01

    The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for magnetic resonance fingerprinting. Based on a singular value decomposition of the signal evolution, magnetic resonance fingerprinting is formulated as a low rank (LR) inverse problem in which one image is reconstructed for each singular value under consideration. This LR approximation of the signal evolution reduces the computational burden by reducing the number of Fourier transformations. Also, the LR approximation improves the conditioning of the problem, which is further improved by extending the LR inverse problem to an augmented Lagrangian that is solved by the alternating direction method of multipliers. The root mean square error and the noise propagation are analyzed in simulations. For verification, in vivo examples are provided. The proposed LR alternating direction method of multipliers approach shows a reduced root mean square error compared to the original fingerprinting reconstruction, to a LR approximation alone and to an alternating direction method of multipliers approach without a LR approximation. Incorporating sensitivity encoding allows for further artifact reduction. The proposed reconstruction provides robust convergence, reduced computational burden and improved image quality compared to other magnetic resonance fingerprinting reconstruction approaches evaluated in this study. Magn Reson Med 79:83-96, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  5. The SRT reconstruction algorithm for semiquantification in PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kastis, George A., E-mail: gkastis@academyofathens.gr [Research Center of Mathematics, Academy of Athens, Athens 11527 (Greece); Gaitanis, Anastasios [Biomedical Research Foundation of the Academy of Athens (BRFAA), Athens 11527 (Greece); Samartzis, Alexandros P. [Nuclear Medicine Department, Evangelismos General Hospital, Athens 10676 (Greece); Fokas, Athanasios S. [Department of Applied Mathematics and Theoretical Physics, University of Cambridge, Cambridge CB30WA, United Kingdom and Research Center of Mathematics, Academy of Athens, Athens 11527 (Greece)

    2015-10-15

    Purpose: The spline reconstruction technique (SRT) is a new, fast algorithm based on a novel numerical implementation of an analytic representation of the inverse Radon transform. The mathematical details of this algorithm and comparisons with filtered backprojection were presented earlier in the literature. In this study, the authors present a comparison between SRT and the ordered-subsets expectation–maximization (OSEM) algorithm for determining contrast and semiquantitative indices of {sup 18}F-FDG uptake. Methods: The authors implemented SRT in the software for tomographic image reconstruction (STIR) open-source platform and evaluated this technique using simulated and real sinograms obtained from the GE Discovery ST positron emission tomography/computer tomography scanner. All simulations and reconstructions were performed in STIR. For OSEM, the authors used the clinical protocol of their scanner, namely, 21 subsets and two iterations. The authors also examined images at one, four, six, and ten iterations. For the simulation studies, the authors analyzed an image-quality phantom with cold and hot lesions. Two different versions of the phantom were employed at two different hot-sphere lesion-to-background ratios (LBRs), namely, 2:1 and 4:1. For each noiseless sinogram, 20 Poisson realizations were created at five different noise levels. In addition to making visual comparisons of the reconstructed images, the authors determined contrast and bias as a function of the background image roughness (IR). For the real-data studies, sinograms of an image-quality phantom simulating the human torso were employed. The authors determined contrast and LBR as a function of the background IR. Finally, the authors present plots of contrast as a function of IR after smoothing each reconstructed image with Gaussian filters of six different sizes. Statistical significance was determined by employing the Wilcoxon rank-sum test. Results: In both simulated and real studies, SRT

  6. The SRT reconstruction algorithm for semiquantification in PET imaging

    International Nuclear Information System (INIS)

    Kastis, George A.; Gaitanis, Anastasios; Samartzis, Alexandros P.; Fokas, Athanasios S.

    2015-01-01

    Purpose: The spline reconstruction technique (SRT) is a new, fast algorithm based on a novel numerical implementation of an analytic representation of the inverse Radon transform. The mathematical details of this algorithm and comparisons with filtered backprojection were presented earlier in the literature. In this study, the authors present a comparison between SRT and the ordered-subsets expectation–maximization (OSEM) algorithm for determining contrast and semiquantitative indices of 18 F-FDG uptake. Methods: The authors implemented SRT in the software for tomographic image reconstruction (STIR) open-source platform and evaluated this technique using simulated and real sinograms obtained from the GE Discovery ST positron emission tomography/computer tomography scanner. All simulations and reconstructions were performed in STIR. For OSEM, the authors used the clinical protocol of their scanner, namely, 21 subsets and two iterations. The authors also examined images at one, four, six, and ten iterations. For the simulation studies, the authors analyzed an image-quality phantom with cold and hot lesions. Two different versions of the phantom were employed at two different hot-sphere lesion-to-background ratios (LBRs), namely, 2:1 and 4:1. For each noiseless sinogram, 20 Poisson realizations were created at five different noise levels. In addition to making visual comparisons of the reconstructed images, the authors determined contrast and bias as a function of the background image roughness (IR). For the real-data studies, sinograms of an image-quality phantom simulating the human torso were employed. The authors determined contrast and LBR as a function of the background IR. Finally, the authors present plots of contrast as a function of IR after smoothing each reconstructed image with Gaussian filters of six different sizes. Statistical significance was determined by employing the Wilcoxon rank-sum test. Results: In both simulated and real studies, SRT

  7. The impact of breast reconstruction on the quality of life of women after mastectomy

    Directory of Open Access Journals (Sweden)

    Agnieszka Rzońca

    2017-04-01

    Results: The largest group of respondents were women over 55 years of age.  More than half of the respondents had children. 80% of the women were satisfied with the effects of the re construction. The most common changes that triggered the reconstruction were improvement of mood, improvement of appearance and increased self-confidence.

  8. Statistical reconstruction for cone-beam CT with a post-artifact-correction noise model: application to high-quality head imaging

    International Nuclear Information System (INIS)

    Dang, H; Stayman, J W; Sisniega, A; Xu, J; Zbijewski, W; Siewerdsen, J H; Wang, X; Foos, D H; Aygun, N; Koliatsos, V E

    2015-01-01

    Non-contrast CT reliably detects fresh blood in the brain and is the current front-line imaging modality for intracranial hemorrhage such as that occurring in acute traumatic brain injury (contrast ∼40–80 HU, size  >  1 mm). We are developing flat-panel detector (FPD) cone-beam CT (CBCT) to facilitate such diagnosis in a low-cost, mobile platform suitable for point-of-care deployment. Such a system may offer benefits in the ICU, urgent care/concussion clinic, ambulance, and sports and military theatres. However, current FPD-CBCT systems face significant challenges that confound low-contrast, soft-tissue imaging. Artifact correction can overcome major sources of bias in FPD-CBCT but imparts noise amplification in filtered backprojection (FBP). Model-based reconstruction improves soft-tissue image quality compared to FBP by leveraging a high-fidelity forward model and image regularization. In this work, we develop a novel penalized weighted least-squares (PWLS) image reconstruction method with a noise model that includes accurate modeling of the noise characteristics associated with the two dominant artifact corrections (scatter and beam-hardening) in CBCT and utilizes modified weights to compensate for noise amplification imparted by each correction. Experiments included real data acquired on a FPD-CBCT test-bench and an anthropomorphic head phantom emulating intra-parenchymal hemorrhage. The proposed PWLS method demonstrated superior noise-resolution tradeoffs in comparison to FBP and PWLS with conventional weights (viz. at matched 0.50 mm spatial resolution, CNR = 11.9 compared to CNR = 5.6 and CNR = 9.9, respectively) and substantially reduced image noise especially in challenging regions such as skull base. The results support the hypothesis that with high-fidelity artifact correction and statistical reconstruction using an accurate post-artifact-correction noise model, FPD-CBCT can achieve image quality allowing reliable detection of

  9. Quality of life following total mastectomy with and without reconstruction versus breast-conserving surgery for breast cancer: A case-controlled cohort study.

    Science.gov (United States)

    Howes, Benjamin H L; Watson, David I; Xu, Chris; Fosh, Beverley; Canepa, Maximiliano; Dean, Nicola R

    2016-09-01

    Patient-reported outcomes and quality of life following mastectomy are not well understood. This study evaluates the quality of life following surgery for breast cancer and compares outcomes following breast-conserving surgery versus total mastectomy with or without reconstruction. A case-controlled cross-sectional study was conducted using the validated BREAST-Q™ questionnaire and a study-specific questionnaire to determine patient's views about surgical outcomes. Questionnaires were completed by patients following breast-conserving surgery and total mastectomy with or without reconstruction and by controls without breast cancer. A one-way ANOVA was used to compare mean BREAST-Q™ scores between groups and post hoc analysis using Tukey's and Kruskal-Wallis tests. BREAST-Q™ questionnaires were completed by 400 women (123 controls, 97 breast conservations, 93 mastectomies without reconstruction, 87 mastectomies with reconstruction). Women who had undergone mastectomy and reconstruction had higher scores in satisfaction with breast and sexual well-being domains compared with women who had breast-conserving surgery, and women who had total mastectomy without reconstruction had the lowest scores in these two domains. There was no difference in psychosocial well-being between the groups. Women who had undergone breast-conserving surgery scored the lowest in the physical well-being chest domain and the majority reported breast asymmetry. Our study suggests that women who undergo total mastectomy and breast reconstruction for cancer achieve a quality-of-life outcome that is at least as good as that following breast-conserving surgery. Furthermore, breast conservation has been found to be associated with lower physical well-being (i.e., more pain and discomfort) in the chest area and poorer sexual well-being outcomes. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. All rights reserved.

  10. Optimization of image quality and acquisition time for lab-based X-ray microtomography using an iterative reconstruction algorithm

    Science.gov (United States)

    Lin, Qingyang; Andrew, Matthew; Thompson, William; Blunt, Martin J.; Bijeljic, Branko

    2018-05-01

    Non-invasive laboratory-based X-ray microtomography has been widely applied in many industrial and research disciplines. However, the main barrier to the use of laboratory systems compared to a synchrotron beamline is its much longer image acquisition time (hours per scan compared to seconds to minutes at a synchrotron), which results in limited application for dynamic in situ processes. Therefore, the majority of existing laboratory X-ray microtomography is limited to static imaging; relatively fast imaging (tens of minutes per scan) can only be achieved by sacrificing imaging quality, e.g. reducing exposure time or number of projections. To alleviate this barrier, we introduce an optimized implementation of a well-known iterative reconstruction algorithm that allows users to reconstruct tomographic images with reasonable image quality, but requires lower X-ray signal counts and fewer projections than conventional methods. Quantitative analysis and comparison between the iterative and the conventional filtered back-projection reconstruction algorithm was performed using a sandstone rock sample with and without liquid phases in the pore space. Overall, by implementing the iterative reconstruction algorithm, the required image acquisition time for samples such as this, with sparse object structure, can be reduced by a factor of up to 4 without measurable loss of sharpness or signal to noise ratio.

  11. Analysis of algebraic reconstruction technique for accurate imaging of gas temperature and concentration based on tunable diode laser absorption spectroscopy

    International Nuclear Information System (INIS)

    Xia Hui-Hui; Kan Rui-Feng; Liu Jian-Guo; Xu Zhen-Yu; He Ya-Bai

    2016-01-01

    An improved algebraic reconstruction technique (ART) combined with tunable diode laser absorption spectroscopy(TDLAS) is presented in this paper for determining two-dimensional (2D) distribution of H 2 O concentration and temperature in a simulated combustion flame. This work aims to simulate the reconstruction of spectroscopic measurements by a multi-view parallel-beam scanning geometry and analyze the effects of projection rays on reconstruction accuracy. It finally proves that reconstruction quality dramatically increases with the number of projection rays increasing until more than 180 for 20 × 20 grid, and after that point, the number of projection rays has little influence on reconstruction accuracy. It is clear that the temperature reconstruction results are more accurate than the water vapor concentration obtained by the traditional concentration calculation method. In the present study an innovative way to reduce the error of concentration reconstruction and improve the reconstruction quality greatly is also proposed, and the capability of this new method is evaluated by using appropriate assessment parameters. By using this new approach, not only the concentration reconstruction accuracy is greatly improved, but also a suitable parallel-beam arrangement is put forward for high reconstruction accuracy and simplicity of experimental validation. Finally, a bimodal structure of the combustion region is assumed to demonstrate the robustness and universality of the proposed method. Numerical investigation indicates that the proposed TDLAS tomographic algorithm is capable of detecting accurate temperature and concentration profiles. This feasible formula for reconstruction research is expected to resolve several key issues in practical combustion devices. (paper)

  12. Recent improvements in Hurricane Imaging Radiometer’s brightness temperature image reconstruction

    Directory of Open Access Journals (Sweden)

    Sayak K. Biswas

    Full Text Available NASA MSFCs airborne Hurricane Imaging Radiometer (HIRAD uses interferometric aperture synthesis to produce high resolution wide swath images of scene brightness temperature (Tb distribution at four discrete C-band microwave frequencies (4.0, 5.0, 6.0 and 6.6 GHz. Images of ocean surface wind speed under heavy precipitation such as in tropical cyclones, is inferred from these measurements. The baseline HIRAD Tb reconstruction algorithm had produced prominent along-track streaks in the Tb images. Particularly the 4.0 GHz channel had been so dominated by the streaks as to be unusable.The loss of a frequency channel had compromised the final wind speed retrievals. During 2016, the HIRAD team made substantial progress in developing a quality controlled signal processing technique for the HIRAD data collected in 2015’s Tropical Cyclone Intensity (TCI experiment and reduced the effect of streaks in all channels including 4.0 GHz. 2000 MSC: 41A05, 41A10, 65D05, 65D17, Keywords: Microwave radiometry, Aperture synthesis, Image reconstruction, Hurricane winds

  13. A new approach for quantitative evaluation of reconstruction algorithms in SPECT

    International Nuclear Information System (INIS)

    Raeisi, E.; Rajabi, H.; Aghamiri, S. M. R.

    2006-01-01

    In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems, and practically there is no phantom exclusively designed for the evaluation of the software performance. In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire tomographic and planar image of the same structure. The planar image may be used as the reference image to evaluate the quality of reconstructed slices, using the companion software developed in MATLAB. Materials and Methods: The designed phantom was composed of 4 independent 2D slices that could have been placed juxtapose to the 3D phantom. Each slice was composed of objects of different size and shape (for example: circle, triangle, and rectangle). Each 2D slice was imaged at distances ranging from 0 to 15 cm from the collimator surface. The phantom in 3D configuration was imaged acquiring 128 views of 128*128 matrix size. Reconstruction was performed using different filtering condition and the reconstructed images were compared to the corresponding planar images. The modulation transfer function, scatter fraction and attenuation map were calculated for each reconstructed image. Results: Since all the parameters of the acquisition were identical for the 2D and the 3D imaging, it was assumed that the difference in the quality of the images has exclusively been due to the reconstruction condition. The planar images were assumed to be the most perfect images which could be obtained with the system. The comparison of the reconstructed slices with the corresponding planar images yielded the optimum reconstruction condition. The results clearly showed that Wiener filter yields superior quality image among the entire tested filters. The extent of the improvement has been quantified in terms of universal image quality index. Conclusion : The phantom and the accompanying software were evaluated and found to be quite useful in

  14. Quality Improvement Initiatives in Inflammatory Bowel Disease.

    Science.gov (United States)

    Berry, Sameer K; Siegel, Corey A; Melmed, Gil Y

    2017-08-01

    This article serves as an overview of several quality improvement initiatives in inflammatory bowel disease (IBD). IBD is associated with significant variation in care, suggesting poor quality of care. There have been several efforts to improve the quality of care for patients with IBD. Quality improvement (QI) initiatives in IBD are intended to be patient-centric, improve outcomes for individuals and populations, and reduce costs-all consistent with "the triple aim" put forth by the Institute for Healthcare Improvement (IHI). Current QI initiatives include the development of quality measure sets to standardize processes and outcomes, learning health systems to foster collaborative improvement, and patient-centered medical homes specific to patients with IBD in shared risk models of care. Some of these programs have demonstrated early success in improving patient outcomes, reducing costs, improving patient satisfaction, and facilitating patient engagement. However, further studies are needed to evaluate and compare the effects of these programs over time on clinical outcomes in order to demonstrate long-term value and sustainability.

  15. Multiview 3D sensing and analysis for high quality point cloud reconstruction

    Science.gov (United States)

    Satnik, Andrej; Izquierdo, Ebroul; Orjesek, Richard

    2018-04-01

    Multiview 3D reconstruction techniques enable digital reconstruction of 3D objects from the real world by fusing different viewpoints of the same object into a single 3D representation. This process is by no means trivial and the acquisition of high quality point cloud representations of dynamic 3D objects is still an open problem. In this paper, an approach for high fidelity 3D point cloud generation using low cost 3D sensing hardware is presented. The proposed approach runs in an efficient low-cost hardware setting based on several Kinect v2 scanners connected to a single PC. It performs autocalibration and runs in real-time exploiting an efficient composition of several filtering methods including Radius Outlier Removal (ROR), Weighted Median filter (WM) and Weighted Inter-Frame Average filtering (WIFA). The performance of the proposed method has been demonstrated through efficient acquisition of dense 3D point clouds of moving objects.

  16. Quality of life long-term after body contouring surgery following bariatric surgery: sustained improvement after 7 years.

    Science.gov (United States)

    van der Beek, Eva S J; Geenen, Rinie; de Heer, Francine A G; van der Molen, Aebele B Mink; van Ramshorst, Bert

    2012-11-01

    Bariatric surgery for morbid obesity results in massive weight loss and improvement of health and quality of life. A downside of the major weight loss is the excess of overstretched skin, which may influence the patient's quality of life by causing functional and aesthetic problems. The purpose of the current study was to evaluate the patient's quality of life long-term after body contouring following bariatric surgery. Quality of life was measured with the Obesity Psychosocial State Questionnaire in 33 post-bariatric surgery patients 7.2 years (range, 3.2 to 13.3 years) after body contouring surgery. Data were compared with previous assessments 4.1 years (range, 0.7 to 9.2 years) after body contouring surgery of the quality of life at that time and before body contouring surgery. Compared with appraisals of quality of life before body contouring surgery, a significant, mostly moderate to large, sustained improvement of quality of life was observed in post-bariatric surgery patients 7.2 years after body contouring surgery in six of the seven psychosocial domains. A small deterioration occurred between 4.1- and 7.2-year follow-up on two of the seven domains except for the domain efficacy toward eating, which showed a significant improvement. At 7-year follow-up, 18 patients (55 percent) were satisfied with the result of body contouring surgery. This study indicates a sustained quality-of-life improvement in post-bariatric surgery patients after body contouring surgery. This suggests the importance of including reconstructive surgery as a component in the multidisciplinary approach in the surgical treatment of morbid obesity. Therapeutic, IV.

  17. 3D dictionary learning based iterative cone beam CT reconstruction

    Directory of Open Access Journals (Sweden)

    Ti Bai

    2014-03-01

    Full Text Available Purpose: This work is to develop a 3D dictionary learning based cone beam CT (CBCT reconstruction algorithm on graphic processing units (GPU to improve the quality of sparse-view CBCT reconstruction with high efficiency. Methods: A 3D dictionary containing 256 small volumes (atoms of 3 × 3 × 3 was trained from a large number of blocks extracted from a high quality volume image. On the basis, we utilized cholesky decomposition based orthogonal matching pursuit algorithm to find the sparse representation of each block. To accelerate the time-consuming sparse coding in the 3D case, we implemented the sparse coding in a parallel fashion by taking advantage of the tremendous computational power of GPU. Conjugate gradient least square algorithm was adopted to minimize the data fidelity term. Evaluations are performed based on a head-neck patient case. FDK reconstruction with full dataset of 364 projections is used as the reference. We compared the proposed 3D dictionary learning based method with tight frame (TF by performing reconstructions on a subset data of 121 projections. Results: Compared to TF based CBCT reconstruction that shows good overall performance, our experiments indicated that 3D dictionary learning based CBCT reconstruction is able to recover finer structures, remove more streaking artifacts and also induce less blocky artifacts. Conclusion: 3D dictionary learning based CBCT reconstruction algorithm is able to sense the structural information while suppress the noise, and hence to achieve high quality reconstruction under the case of sparse view. The GPU realization of the whole algorithm offers a significant efficiency enhancement, making this algorithm more feasible for potential clinical application.-------------------------------Cite this article as: Bai T, Yan H, Shi F, Jia X, Lou Y, Xu Q, Jiang S, Mou X. 3D dictionary learning based iterative cone beam CT reconstruction. Int J Cancer Ther Oncol 2014; 2(2:020240. DOI: 10

  18. Process safety improvement-Quality and target zero

    Energy Technology Data Exchange (ETDEWEB)

    Van Scyoc, Karl [Det Norske Veritas (U.S.A.) Inc., DNV Energy Solutions, 16340 Park Ten Place, Suite 100, Houston, TX 77084 (United States)], E-mail: karl.van.scyoc@dnv.com

    2008-11-15

    Process safety practitioners have adopted quality management principles in design of process safety management systems with positive effect, yet achieving safety objectives sometimes remain a distant target. Companies regularly apply tools and methods which have roots in quality and productivity improvement. The 'plan, do, check, act' improvement loop, statistical analysis of incidents (non-conformities), and performance trending popularized by Dr. Deming are now commonly used in the context of process safety. Significant advancements in HSE performance are reported after applying methods viewed as fundamental for quality management. In pursuit of continual process safety improvement, the paper examines various quality improvement methods, and explores how methods intended for product quality can be additionally applied to continual improvement of process safety. Methods such as Kaizen, Poke yoke, and TRIZ, while long established for quality improvement, are quite unfamiliar in the process safety arena. These methods are discussed for application in improving both process safety leadership and field work team performance. Practical ways to advance process safety, based on the methods, are given.

  19. Process safety improvement-Quality and target zero

    International Nuclear Information System (INIS)

    Van Scyoc, Karl

    2008-01-01

    Process safety practitioners have adopted quality management principles in design of process safety management systems with positive effect, yet achieving safety objectives sometimes remain a distant target. Companies regularly apply tools and methods which have roots in quality and productivity improvement. The 'plan, do, check, act' improvement loop, statistical analysis of incidents (non-conformities), and performance trending popularized by Dr. Deming are now commonly used in the context of process safety. Significant advancements in HSE performance are reported after applying methods viewed as fundamental for quality management. In pursuit of continual process safety improvement, the paper examines various quality improvement methods, and explores how methods intended for product quality can be additionally applied to continual improvement of process safety. Methods such as Kaizen, Poke yoke, and TRIZ, while long established for quality improvement, are quite unfamiliar in the process safety arena. These methods are discussed for application in improving both process safety leadership and field work team performance. Practical ways to advance process safety, based on the methods, are given

  20. Process safety improvement--quality and target zero.

    Science.gov (United States)

    Van Scyoc, Karl

    2008-11-15

    Process safety practitioners have adopted quality management principles in design of process safety management systems with positive effect, yet achieving safety objectives sometimes remain a distant target. Companies regularly apply tools and methods which have roots in quality and productivity improvement. The "plan, do, check, act" improvement loop, statistical analysis of incidents (non-conformities), and performance trending popularized by Dr. Deming are now commonly used in the context of process safety. Significant advancements in HSE performance are reported after applying methods viewed as fundamental for quality management. In pursuit of continual process safety improvement, the paper examines various quality improvement methods, and explores how methods intended for product quality can be additionally applied to continual improvement of process safety. Methods such as Kaizen, Poke yoke, and TRIZ, while long established for quality improvement, are quite unfamiliar in the process safety arena. These methods are discussed for application in improving both process safety leadership and field work team performance. Practical ways to advance process safety, based on the methods, are given.

  1. Reconstruction of emission coefficients for a non-axisymmetric coupling arc by algebraic reconstruction technique

    International Nuclear Information System (INIS)

    Zhang Guangjun; Xiong Jun; Gao Hongming; Wu Lin

    2011-01-01

    A preliminary investigation of tomographic reconstruction of an asymmetric arc plasma has been carried out. The objective of this work aims at reconstructing emission coefficients of a non-axisymmetric coupling arc from measured intensities by means of an algebraic reconstruction technique (ART). In order to define the optimal experimental scheme for good quality with limited views, the dependence of the reconstruction quality on three configurations (four, eight, ten projection angles) are presented and discussed via a displaced Gaussian model. Then, the emission coefficients of a free burning arc are reconstructed by the ART with the ten-view configuration and an Abel inversion, respectively, and good agreement is obtained. Finally, the emission coefficient profiles of the coupling arc are successfully achieved with the ten-view configuration. The results show that the distribution of emission coefficient for the coupling arc is different from centrosymmetric shape. The ART is perfectly suitable for reconstructing emission coefficients of the coupling arc with the ten-view configuration, proving the feasibility and utility of the ART to characterize an asymmetric arc.

  2. Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective

    Energy Technology Data Exchange (ETDEWEB)

    Brady, S. L.; Yee, B. S.; Kaufman, R. A. [Department of Radiological Sciences, St. Jude Children' s Research Hospital, Memphis, Tennessee 38105 (United States)

    2012-09-15

    Purpose: This study demonstrates a means of implementing an adaptive statistical iterative reconstruction (ASiR Trade-Mark-Sign ) technique for dose reduction in computed tomography (CT) while maintaining similar noise levels in the reconstructed image. The effects of image quality and noise texture were assessed at all implementation levels of ASiR Trade-Mark-Sign . Empirically derived dose reduction limits were established for ASiR Trade-Mark-Sign for imaging of the trunk for a pediatric oncology population ranging from 1 yr old through adolescence/adulthood. Methods: Image quality was assessed using metrics established by the American College of Radiology (ACR) CT accreditation program. Each image quality metric was tested using the ACR CT phantom with 0%-100% ASiR Trade-Mark-Sign blended with filtered back projection (FBP) reconstructed images. Additionally, the noise power spectrum (NPS) was calculated for three common reconstruction filters of the trunk. The empirically derived limitations on ASiR Trade-Mark-Sign implementation for dose reduction were assessed using (1, 5, 10) yr old and adolescent/adult anthropomorphic phantoms. To assess dose reduction limits, the phantoms were scanned in increments of increased noise index (decrementing mA using automatic tube current modulation) balanced with ASiR Trade-Mark-Sign reconstruction to maintain noise equivalence of the 0% ASiR Trade-Mark-Sign image. Results: The ASiR Trade-Mark-Sign algorithm did not produce any unfavorable effects on image quality as assessed by ACR criteria. Conversely, low-contrast resolution was found to improve due to the reduction of noise in the reconstructed images. NPS calculations demonstrated that images with lower frequency noise had lower noise variance and coarser graininess at progressively higher percentages of ASiR Trade-Mark-Sign reconstruction; and in spite of the similar magnitudes of noise, the image reconstructed with 50% or more ASiR Trade-Mark-Sign presented a more

  3. Ways of improving preparatory stage and reconstruction of coking plants

    Energy Technology Data Exchange (ETDEWEB)

    Rozenfel' d, M.S.; Martynenko, V.M.; Svyatogorov, A.A.; Kvitkin, I.A.; Zhurba, A.I.; Gurtovnik, P.F.

    1987-06-01

    Discusses economic and technological aspects of coking plant reconstruction and modernization in the USSR. Effects of standardized technologies on plant reconstruction are analyzed. A standardized planning procedure jointly developed by research institutes in the USSR for plant modernization or reconstruction is discussed: selecting the optimum reconstruction and repair time, sequence of operations without stoppage of a coke oven battery, coke oven cooling, repair of coke oven liners, heating systems, coke oven equipment, drying, initial heating, testing battery equipment. The procedure is aimed at reducing coke losses and eliminating delays during reconstruction operations. A graphic method for modelling plant reconstruction is discussed.

  4. Quality Improvement and Learning in Productive Systems

    OpenAIRE

    Charles H. Fine

    1986-01-01

    Recent interest in product quality suggests that effort devoted to improving the quality of manufactured products may reduce unit costs. This conjecture---that improving quality can lower costs---challenges the traditional assumption that unit costs increase with increased quality assurance activities and has significant implications for quality management. By introducing the idea of a quality-based learning curve, this paper links the previously disjoint literatures of quality control and le...

  5. Improving care at cystic fibrosis centers through quality improvement.

    Science.gov (United States)

    Kraynack, Nathan C; McBride, John T

    2009-10-01

    Quality improvement (QI) using a clinical microsystems approach provides cystic fibrosis (CF) centers the opportunity to make a significant positive impact on the health of their patients. The availability of center-specific outcomes data and the support of the Cystic Fibrosis Foundation are important advantages for these quality improvement efforts. This article illustrates how the clinical microsystems methodology can improve care delivery and outcomes by describing the gradual application of quality improvement principles over the past 5 years by the CF team at the Lewis Walker Cystic Fibrosis Center at Akron Children's Hospital in Akron, Ohio. Using the example of a project to improve the pulmonary function of the pediatric patients at our center as a framework, we describe the QI process from the initial team-building phase, through the assessment of care processes, standardization of care, and developing a culture of continuous improvement. We outline how enthusiastic commitment from physician leadership, clinical managers and central administration, the availability of coaches, and an appreciation of the importance of measurement, patient involvement, communication, and standardization are critical components for successful process improvement. Copyright Thieme Medical Publishers.

  6. Statistical methods for quality improvement

    National Research Council Canada - National Science Library

    Ryan, Thomas P

    2011-01-01

    ...."-TechnometricsThis new edition continues to provide the most current, proven statistical methods for quality control and quality improvementThe use of quantitative methods offers numerous benefits...

  7. Prospective regularization design in prior-image-based reconstruction

    International Nuclear Information System (INIS)

    Dang, Hao; Siewerdsen, Jeffrey H; Stayman, J Webster

    2015-01-01

    Prior-image-based reconstruction (PIBR) methods leveraging patient-specific anatomical information from previous imaging studies and/or sequences have demonstrated dramatic improvements in dose utilization and image quality for low-fidelity data. However, a proper balance of information from the prior images and information from the measurements is required (e.g. through careful tuning of regularization parameters). Inappropriate selection of reconstruction parameters can lead to detrimental effects including false structures and failure to improve image quality. Traditional methods based on heuristics are subject to error and sub-optimal solutions, while exhaustive searches require a large number of computationally intensive image reconstructions. In this work, we propose a novel method that prospectively estimates the optimal amount of prior image information for accurate admission of specific anatomical changes in PIBR without performing full image reconstructions. This method leverages an analytical approximation to the implicitly defined PIBR estimator, and introduces a predictive performance metric leveraging this analytical form and knowledge of a particular presumed anatomical change whose accurate reconstruction is sought. Additionally, since model-based PIBR approaches tend to be space-variant, a spatially varying prior image strength map is proposed to optimally admit changes everywhere in the image (eliminating the need to know change locations a priori). Studies were conducted in both an ellipse phantom and a realistic thorax phantom emulating a lung nodule surveillance scenario. The proposed method demonstrated accurate estimation of the optimal prior image strength while achieving a substantial computational speedup (about a factor of 20) compared to traditional exhaustive search. Moreover, the use of the proposed prior strength map in PIBR demonstrated accurate reconstruction of anatomical changes without foreknowledge of change locations in

  8. A Qualitative Study of Breast Reconstruction Decision-Making among Asian Immigrant Women Living in the United States.

    Science.gov (United States)

    Fu, Rose; Chang, Michelle Milee; Chen, Margaret; Rohde, Christine Hsu

    2017-02-01

    Despite research supporting improved psychosocial well-being, quality of life, and survival for patients undergoing postmastectomy breast reconstruction, Asian patients remain one-fifth as likely as Caucasians to choose reconstruction. This study investigates cultural factors, values, and perceptions held by Asian women that might impact breast reconstruction rates. The authors conducted semistructured interviews of immigrant East Asian women treated for breast cancer in the New York metropolitan area, investigating social structure, culture, attitudes toward surgery, and body image. Three investigators independently coded transcribed interviews, and then collectively evaluated them through axial coding of recurring themes. Thirty-five immigrant East Asian women who underwent surgical treatment for breast cancer were interviewed. Emerging themes include functionality, age, perceptions of plastic surgery, inconvenience, community/family, fear of implants, language, and information. Patients spoke about breasts as a function of their roles as a wife or mother, eliminating the need for breasts when these roles were fulfilled. Many addressed the fear of multiple operations. Quality and quantity of information, and communication with practitioners, impacted perceptions about treatment. Reconstructive surgery was often viewed as cosmetic. Community and family played a significant role in decision-making. Asian women are statistically less likely than Caucasians to pursue breast reconstruction. This is the first study to investigate culture-specific perceptions of breast reconstruction. Results from this study can be used to improve cultural competency in addressing patient concerns. Improving access to information regarding treatment options and surgical outcomes may improve informed decision-making among immigrant Asian women.

  9. Genital reconstruction in exstrophy patients

    Directory of Open Access Journals (Sweden)

    R B Nerli

    2012-01-01

    Full Text Available Introduction: Surgery for bladder exstrophy has been evolving over the last four to five decades. Because survival has become almost universal, the focus has changed in the exstrophy-epispadias complex to improving quality of life. The most prevalent problem in the long-term function of exstrophy patients is the sexual activity of the adolescent and adult males. The penis in exstrophy patients appears short because of marked congenital deficiency of anterior corporal tissue. Many patients approach for genital reconstruction to improve cosmesis as well as to correct chordee. We report our series of male patients seeking genital reconstruction following exstrophy repair in the past. Materials and Methods: Fourteen adolescent/adult male patients attended urology services during the period January 2000-December 2009 seeking genital reconstruction following exstrophy repair in the past. Results: Three patients underwent epispadias repair, four patients had chordee correction with cosmetic excision of skin tags and seven patients underwent chordee correction with penile lengthening. All patients reported satisfaction in the answered questionnaire. Patients undergoing penile lengthening by partial corporal dissection achieved a mean increase in length of 1.614 ± 0.279 cm dorsally and 1.543 ± 0.230 cm ventrally. The satisfactory rate assessed by the Short Form-36 (SF-36 showed that irrespective of the different genital reconstructive procedures done, the patients were satisfied with cosmetic and functional outcome. Conclusions: Surgical procedures have transformed the management in these patients with bladder exstrophy. Bladders can be safely placed within the pelvis, with most patients achieving urinary continence and cosmetically acceptable external genitalia. Genital reconstruction in the form of correction of chordee, excision of ugly skin tags and lengthening of penis can be performed to give the patients a satisfactory cosmetic and functional

  10. Quality improvement in neurological surgery graduate medical education.

    Science.gov (United States)

    Parker, Scott L; McGirt, Matthew J; Asher, Anthony L; Selden, Nathan R

    2015-04-01

    There has been no formal, standardized curriculum for neurosurgical resident education in quality improvement. There are at least 2 reasons to integrate a formalized quality improvement curriculum into resident education: (1) increased emphasis on the relative quality and value (cost-effectiveness) of health care provided by individual physicians, and (2) quality improvement principles empower broader lifelong learning. An integrated quality improvement curriculum should comprise specific goals and milestones at each level of residency training. This article discusses the role and possible implementation of a national program for quality improvement in neurosurgical resident education. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Distributed 3-D iterative reconstruction for quantitative SPECT

    International Nuclear Information System (INIS)

    Ju, Z.W.; Frey, E.C.; Tsui, B.M.W.

    1995-01-01

    The authors describe a distributed three dimensional (3-D) iterative reconstruction library for quantitative single-photon emission computed tomography (SPECT). This library includes 3-D projector-backprojector pairs (PBPs) and distributed 3-D iterative reconstruction algorithms. The 3-D PBPs accurately and efficiently model various combinations of the image degrading factors including attenuation, detector response and scatter response. These PBPs were validated by comparing projection data computed using the projectors with that from direct Monte Carlo (MC) simulations. The distributed 3-D iterative algorithms spread the projection-backprojection operations for all the projection angles over a heterogeneous network of single or multi-processor computers to reduce the reconstruction time. Based on a master/slave paradigm, these distributed algorithms provide dynamic load balancing and fault tolerance. The distributed algorithms were verified by comparing images reconstructed using both the distributed and non-distributed algorithms. Computation times for distributed 3-D reconstructions running on up to 4 identical processors were reduced by a factor approximately 80--90% times the number of the processors participating, compared to those for non-distributed 3-D reconstructions running on a single processor. When combined with faster affordable computers, this library provides an efficient means for implementing accurate reconstruction and compensation methods to improve quality and quantitative accuracy in SPECT images

  12. Preanalytical quality improvement: in quality we trust.

    Science.gov (United States)

    Lippi, Giuseppe; Becan-McBride, Kathleen; Behúlová, Darina; Bowen, Raffick A; Church, Stephen; Delanghe, Joris; Grankvist, Kjell; Kitchen, Steve; Nybo, Mads; Nauck, Matthias; Nikolac, Nora; Palicka, Vladimir; Plebani, Mario; Sandberg, Sverre; Simundic, Ana-Maria

    2013-01-01

    Total quality in laboratory medicine should be defined as the guarantee that each activity throughout the total testing process is correctly performed, providing valuable medical decision-making and effective patient care. In the past decades, a 10-fold reduction in the analytical error rate has been achieved thanks to improvements in both reliability and standardization of analytical techniques, reagents, and instrumentation. Notable advances in information technology, quality control and quality assurance methods have also assured a valuable contribution for reducing diagnostic errors. Nevertheless, several lines of evidence still suggest that most errors in laboratory diagnostics fall outside the analytical phase, and the pre- and postanalytical steps have been found to be much more vulnerable. This collective paper, which is the logical continuum of the former already published in this journal 2 years ago, provides additional contribution to risk management in the preanalytical phase and is a synopsis of the lectures of the 2nd European Federation of Clinical Chemistry and Laboratory Medicine (EFLM)-Becton Dickinson (BD) European Conference on Preanalytical Phase meeting entitled "Preanalytical quality improvement: in quality we trust" (Zagreb, Croatia, 1-2 March 2013). The leading topics that will be discussed include quality indicators for preanalytical phase, phlebotomy practices for collection of blood gas analysis and pediatric samples, lipemia and blood collection tube interferences, preanalytical requirements of urinalysis, molecular biology hemostasis and platelet testing, as well as indications on best practices for safe blood collection. Auditing of the preanalytical phase by ISO assessors and external quality assessment for preanalytical phase are also discussed.

  13. 16-slice multi-detector row CT coronary angiography: image quality and optimization of the image reconstruction window

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Shim, Sung Shine; Lim, Soo Mee; Hwang, Ji Young; Kim, Yoon Kyung

    2005-01-01

    The purpose of this experiment is to investigate the image quality of CT coronary angiography using a 16-slice multi-detector row CT and to determine the optimal image reconstruction window. CT coronary angiography was obtained in 36 nonsymptomatic volunteers using a 16-slice multi-detector row CT (SOMATOM Sensation, Siemens Medical System). The mean heart rates were 70 beats per minute (bpm) or less in 18 persons and more than 70 bpm in 18 persons. Eleven data sets were obtained for each patient (reconstructed at 30%-80% of the cardiac cycle with an increment of 5%). Image quality of the eight coronary segments [left main coronary artery (LM), proximal and middle segments of left anterior descending artery (p-LAD, m-LAN) and left circumflex coronary artery (p-LCx, m-LCx) and proximal, middle and distal segments of right coronary artery (p-RCA, m-RCA, d-RCA)] was assessed. The optimal reconstruction windows in the cardiac cycle for the best image quality were 60-70% for the segments of the LM, LAD, and LC arteries in two groups (bpm 70) and 55-65% (bpm 70) for the segments of the RCA. On the best dataset for each coronary segment, the following diagnostic image quality was achieved in the two groups: LM: 100%, 83%; p-LAD: 100%, 88% m-LAD: 100%, 72%; p-LCx: 100%, 72%; m-LCx: 100%, 72%; p-RCA: 94%, 72%; m-RCA: 61%, 50%; d-RCA: 100%, 80%. The 16 slice multi-detector row CT scan provided visualization of the coronary arteries with high resolution. Especially in the group with a mean heart rate of 70 bpm or less, all the coronary segments except the RCA showed diagnostic image quality. Optimal image quality was achieved with a 60-70% trigger delay for all coronary arterial segments, but the best images of RCA were achieved in the earlier cardiac phase in the patients with a mean heart rate of more than 70 bpm

  14. Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imaging

    DEFF Research Database (Denmark)

    Enevoldsen, Lotte H; Menashi, Changez A K; Andersen, Ulrik B

    2013-01-01

    time (HT) protocols and Evolution for Cardiac Software. METHODS: We studied 45 consecutive, non-selected patients referred for a clinically indicated routine 2-day stress/rest (99m)Tc-Sestamibi myocardial perfusion SPECT. All patients underwent an FT and an HT scan. Both FT and HT scans were processed......-RR) and for quantitative analysis (FT-FBP, HT-FBP, and HT-RR). The datasets were analyzed using commercially available QGS/QPS software and read by two observers evaluating image quality and clinical interpretation. Image quality was assessed on a 10-cm visual analog scale score. RESULTS: HT imaging was associated......: Use of RR reconstruction algorithms compensates for loss of image quality associated with reduced scan time. Both HT acquisition and RR reconstruction algorithm had significant effects on motion and perfusion parameters obtained with standard software, but these effects were relatively small...

  15. Improve strategic supplier performance using DMAIC to develop a Quality Improvement Plan

    Science.gov (United States)

    Jardim, Kevin P.

    Supplier performance that meets the requirements of the customer has long plagued quality professionals. Despite the vast efforts by organizations to improve supplier performance, little has been done to standardize the plan to improve performance. This project presents a guideline and problem-solving strategy using a Define, Measure, Analyze, Improve, and Control (DMAIC) structured tool that will assist in the management and improvement of supplier performance. An analysis of benchmarked Quality Improvement Plans indicated that this topic needs more focus on how to accomplish improved supplier performance. This project is part of a growing body of supplier continuous improvement efforts. With the input of Zodiac Aerospace quality professionals this project's results provide a solution to Quality Improvement Plans and show objective evidence of its benefits. This project contributes to the future research on similar topics.

  16. Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

    Directory of Open Access Journals (Sweden)

    Hyeon Sik Kim

    2014-10-01

    Full Text Available Objective(s: In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF measurement by dynamic N-13 ammonia positron emission tomography (PET, we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; age: 57, 53, and 76 years were reconstructed, using filtered back projection (FBP and ordered subset expectation maximization (OSEM methods. OSEM reconstruction consisted of OSEM_2I, OSEM_4I, and OSEM_6I with 2, 4, and 6 iterations, respectively. The images, reconstructed and filtered by Gaussian filters of 5, 10, and 15 mm, were obtained, as well as non-filtered images. Visual analysis of image quality (IQ was performed using a 3-grade scoring system by 2 independent readers, blinded to the reconstruction and filtering methods of stress images. Then, signal-to-noise ratio (SNR was calculated by noise and contrast recovery (CR. Stress and rest MBF and coronary flow reserve (CFR were obtained for each method. IQ scores, stress and rest MBF, and CFR were compared between the methods, using Chi-square and Kruskal-Wallis tests. Results: In the visual analysis, IQ was significantly higher by 10 mm Gaussian filtering, compared to other sizes of filter (PP=0.923 and 0.855 for readers 1 and 2, respectively. SNR was significantly higher in 10 mm Gaussian filter. There was a significant difference in stress and rest MBF between several vascular territories. However CFR was not significantly different according to various filtering methods. Conclusion: Post-reconstruction Gaussian filtering with a filter size of 10 mm significantly enhances the IQ of N-13 ammonia PET-CT, without changing the results of CFR calculation. .

  17. Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

    International Nuclear Information System (INIS)

    Kim, Hyeon Sik; Cho, Sang-Geon; Kim, Ju Han; Kwon, Seong Young; Lee, Byeong-il; Bom, Hee-Seung

    2014-01-01

    In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; age: 57, 53, and 76 years) were reconstructed, using filtered back projection (FBP) and ordered subset expectation maximization (OSEM) methods. OSEM reconstruction consisted of OSEM-2I, OSEM-4I, and OSEM-6I with 2, 4, and 6 iterations, respectively. The images, reconstructed and filtered by Gaussian filters of 5, 10, and 15 mm, were obtained, as well as non-filtered images. Visual analysis of image quality (IQ) was performed using a 3-grade scoring system by 2 independent readers, blinded to the reconstruction and filtering methods of stress images. Then, signal-to-noise ratio (SNR) was calculated by noise and contrast recovery (CR). Stress and rest MBF and coronary flow reserve (CFR) were obtained for each method. IQ scores, stress and rest MBF, and CFR were compared between the methods, using Chi-square and Kruskal-Wallis tests. In the visual analysis, IQ was significantly higher by 10 mm Gaussian filtering, compared to other sizes of filter (P<0.001 for both readers). However, no significant difference of IQ was found between FBP and various numbers of iteration in OSEM (P=0.923 and 0.855 for readers 1 and 2, respectively). SNR was significantly higher in 10 mm Gaussian filter. There was a significant difference in stress and rest MBF between several vascular territories. However CFR was not significantly different according to various filtering methods. Post-reconstruction Gaussian filtering with a filter size of 10 mm significantly enhances the IQ of N-13 ammonia PET-CT, without changing the results of CFR calculation

  18. Research of ART method in CT image reconstruction

    International Nuclear Information System (INIS)

    Li Zhipeng; Cong Peng; Wu Haifeng

    2005-01-01

    This paper studied Algebraic Reconstruction Technique (ART) in CT image reconstruction. Discussed the ray number influence on image quality. And the adopting of smooth method got high quality CT image. (authors)

  19. Image Quality of 3rd Generation Spiral Cranial Dual-Source CT in Combination with an Advanced Model Iterative Reconstruction Technique: A Prospective Intra-Individual Comparison Study to Standard Sequential Cranial CT Using Identical Radiation Dose.

    Science.gov (United States)

    Wenz, Holger; Maros, Máté E; Meyer, Mathias; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O; Flohr, Thomas; Leidecker, Christianne; Groden, Christoph; Scharf, Johann; Henzler, Thomas

    2015-01-01

    To prospectively intra-individually compare image quality of a 3rd generation Dual-Source-CT (DSCT) spiral cranial CT (cCT) to a sequential 4-slice Multi-Slice-CT (MSCT) while maintaining identical intra-individual radiation dose levels. 35 patients, who had a non-contrast enhanced sequential cCT examination on a 4-slice MDCT within the past 12 months, underwent a spiral cCT scan on a 3rd generation DSCT. CTDIvol identical to initial 4-slice MDCT was applied. Data was reconstructed using filtered backward projection (FBP) and 3rd-generation iterative reconstruction (IR) algorithm at 5 different IR strength levels. Two neuroradiologists independently evaluated subjective image quality using a 4-point Likert-scale and objective image quality was assessed in white matter and nucleus caudatus with signal-to-noise ratios (SNR) being subsequently calculated. Subjective image quality of all spiral cCT datasets was rated significantly higher compared to the 4-slice MDCT sequential acquisitions (pspiral compared to sequential cCT datasets with mean SNR improvement of 61.65% (p*Bonferroni0.05spiral cCT with an advanced model IR technique significantly improves subjective and objective image quality compared to a standard sequential cCT acquisition acquired at identical dose levels.

  20. Improving Family Meetings in Intensive Care Units: A Quality Improvement Curriculum.

    Science.gov (United States)

    Gruenewald, David A; Gabriel, Michelle; Rizzo, Dorothy; Luhrs, Carol A

    2017-07-01

    Family meetings in the intensive care unit are associated with beneficial outcomes for patients, their families, and health care systems, yet these meetings often do not occur in a timely, effective, reliable way. The Department of Veterans Affairs Comprehensive End-of-Life Care Implementation Center sponsored a national initiative to improve family meetings in Veterans Affairs intensive care units across the United States. Process measures of success for the initiative were identified, including development of a curriculum to support facility-based quality improvement projects to implement high-quality family meetings. Identified curriculum requirements included suitability for distance learning and applicability to many clinical intensive care units. Curriculum modules were cross-mapped to the "Plan-Do-Study-Act" model to aid in planning quality improvement projects. A questionnaire was e-mailed to users to evaluate the curriculum's effectiveness. Users rated the curriculum's effectiveness in supporting and achieving aims of the initiative as 3.6 on a scale of 0 (not effective) to 4 (very effective). Users adapted the curriculum to meet local needs. The number of users increased from 6 to 17 quality improvement teams in 2 years. All but 3 teams progressed to implementation of an action plan. Users were satisfied with the effectiveness and adaptability of a family-meeting quality improvement curriculum to support implementation of a quality improvement project in Veterans Affairs intensive care units. This tool may be useful in facilitating projects to improve the quality of family meetings in other intensive care units. ©2017 American Association of Critical-Care Nurses.

  1. Optimization-based reconstruction for reduction of CBCT artifact in IGRT

    Science.gov (United States)

    Xia, Dan; Zhang, Zheng; Paysan, Pascal; Seghers, Dieter; Brehm, Marcus; Munro, Peter; Sidky, Emil Y.; Pelizzari, Charles; Pan, Xiaochuan

    2016-04-01

    Kilo-voltage cone-beam computed tomography (CBCT) plays an important role in image guided radiation therapy (IGRT) by providing 3D spatial information of tumor potentially useful for optimizing treatment planning. In current IGRT CBCT system, reconstructed images obtained with analytic algorithms, such as FDK algorithm and its variants, may contain artifacts. In an attempt to compensate for the artifacts, we investigate optimization-based reconstruction algorithms such as the ASD-POCS algorithm for potentially reducing arti- facts in IGRT CBCT images. In this study, using data acquired with a physical phantom and a patient subject, we demonstrate that the ASD-POCS reconstruction can significantly reduce artifacts observed in clinical re- constructions. Moreover, patient images reconstructed by use of the ASD-POCS algorithm indicate a contrast level of soft-tissue improved over that of the clinical reconstruction. We have also performed reconstructions from sparse-view data, and observe that, for current clinical imaging conditions, ASD-POCS reconstructions from data collected at one half of the current clinical projection views appear to show image quality, in terms of spatial and soft-tissue-contrast resolution, higher than that of the corresponding clinical reconstructions.

  2. Image quality in thoracic 4D cone-beam CT: A sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing

    OpenAIRE

    Shieh, Chun-Chien; Kipritidis, John; O’Brien, Ricky T.; Kuncic, Zdenka; Keall, Paul J.

    2014-01-01

    Purpose: Respiratory signal, binning method, and reconstruction algorithm are three major controllable factors affecting image quality in thoracic 4D cone-beam CT (4D-CBCT), which is widely used in image guided radiotherapy (IGRT). Previous studies have investigated each of these factors individually, but no integrated sensitivity analysis has been performed. In addition, projection angular spacing is also a key factor in reconstruction, but how it affects image quality is not obvious. An inv...

  3. Development of 'Enhance reconstruction package' software for whole-body PET

    International Nuclear Information System (INIS)

    Mizuta, Tetsuro; Imanishi, Tatsuru; Ishikawa, Akihiro

    2011-01-01

    We have developed 'Enhance Reconstruction Package' Software for our whole-body positron emission tomography (PET) Eminence series. This package improves image quality and streamlines the workflow in clinical PET and PET/CT studies. The present paper describes an outline of the applications for data collection, normalization, etc. and also reports some PET images obtained by the software. The signal to noise ratio was optimized in the phantom study, leading to the improvement in image quality. The real time display tool and the remote control tool would make a contribution to enhancement in operability in the routine workflow. (author)

  4. The impact of heart rate on image quality and reconstruction timing of dual-source CT coronary angiography

    International Nuclear Information System (INIS)

    Wang Yining; Jin Zhengyu; Kong Lingyan; Zhang Zhuhua; Song Lan; Mu Wenbin; Wang Yun; Zhao Wenmin; Zhang Shuyang; Lin Songbai

    2008-01-01

    Objective: To evaluate the impact of patient's heart rate (HR) on coronary CT angiography (CTA) image quality (IQ) and reconstruction timing in dual-source CT (DSCT). Methods Ninety-five patients with suspicion of coronary artery disease were examined with a DSCT scanner (Somatom Definition, Siemens) using 32 x 0.6 mm collimation. All patients were divided three groups according to the heart rate (HR): group 1, HR ≤ 70 beats per minute (bpm), n=26; group 2, HR >70 bpm to ≤90 bpm, n=37; group 3, HR > 90 bpm, n=32. No beta-blockers were taken before CT scan. 50- 60 ml of nonionic contrast agent were injected with a rate of 5 ml/s. Images were reconstructed from 10% to 100% of the R-R interval using single-segment reconstruction. Two readers independently assessed IQ of all coronary, segments using a 3-point scale from excellent (1) to non-assessable (3) for coronary segments and the relationship between IQ and the HR. Results: Overall mean IQ score was 1.31 ± 0.55 for all patients with 1.08 ± 0.27 for group 1, 1.32 ± 0.58 for group 2 and 1.47 ± 0.61 for group 3. The IQ was better in the LAD than the RCA and LCX (P<0.01). Only 1.4% (19/1386) of coronary artery segments were considered non-assessable due to the motion artifacts. Optimal image quality of all coronary segments in 74 patients (77.9%) can be achieved with one reconstruction data set. The best IQ was predominately in diastole (88.5%) in group 1, while the best IQ was in systole (84.4%) in group 3. Conclusions: DSCT can achieve the optimal IQ with a wide range of HR using single-segment reconstruction. With the increasing of HR, the timing of data reconstruction for the best IQ shifts from mid-diastole to systole. (authors)

  5. Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET

    International Nuclear Information System (INIS)

    Ahn, Sangtae; Asma, Evren; Cheng, Lishui; Manjeshwar, Ravindra M; Ross, Steven G; Miao, Jun; Jin, Xiao; Wollenweber, Scott D

    2015-01-01

    Ordered subset expectation maximization (OSEM) is the most widely used algorithm for clinical PET image reconstruction. OSEM is usually stopped early and post-filtered to control image noise and does not necessarily achieve optimal quantitation accuracy. As an alternative to OSEM, we have recently implemented a penalized likelihood (PL) image reconstruction algorithm for clinical PET using the relative difference penalty with the aim of improving quantitation accuracy without compromising visual image quality. Preliminary clinical studies have demonstrated visual image quality including lesion conspicuity in images reconstructed by the PL algorithm is better than or at least as good as that in OSEM images. In this paper we evaluate lesion quantitation accuracy of the PL algorithm with the relative difference penalty compared to OSEM by using various data sets including phantom data acquired with an anthropomorphic torso phantom, an extended oval phantom and the NEMA image quality phantom; clinical data; and hybrid clinical data generated by adding simulated lesion data to clinical data. We focus on mean standardized uptake values and compare them for PL and OSEM using both time-of-flight (TOF) and non-TOF data. The results demonstrate improvements of PL in lesion quantitation accuracy compared to OSEM with a particular improvement in cold background regions such as lungs. (paper)

  6. Performance measurement of PSF modeling reconstruction (True X) on Siemens Biograph TruePoint TrueV PET/CT.

    Science.gov (United States)

    Lee, Young Sub; Kim, Jin Su; Kim, Kyeong Min; Kang, Joo Hyun; Lim, Sang Moo; Kim, Hee-Joung

    2014-05-01

    The Siemens Biograph TruePoint TrueV (B-TPTV) positron emission tomography (PET) scanner performs 3D PET reconstruction using a system matrix with point spread function (PSF) modeling (called the True X reconstruction). PET resolution was dramatically improved with the True X method. In this study, we assessed the spatial resolution and image quality on a B-TPTV PET scanner. In addition, we assessed the feasibility of animal imaging with a B-TPTV PET and compared it with a microPET R4 scanner. Spatial resolution was measured at center and at 8 cm offset from the center in transverse plane with warm background activity. True X, ordered subset expectation maximization (OSEM) without PSF modeling, and filtered back-projection (FBP) reconstruction methods were used. Percent contrast (% contrast) and percent background variability (% BV) were assessed according to NEMA NU2-2007. The recovery coefficient (RC), non-uniformity, spill-over ratio (SOR), and PET imaging of the Micro Deluxe Phantom were assessed to compare image quality of B-TPTV PET with that of the microPET R4. When True X reconstruction was used, spatial resolution was RC with True X reconstruction was higher than that with the FBP method and the OSEM without PSF modeling method on the microPET R4. The non-uniformity with True X reconstruction was higher than that with FBP and OSEM without PSF modeling on microPET R4. SOR with True X reconstruction was better than that with FBP or OSEM without PSF modeling on the microPET R4. This study assessed the performance of the True X reconstruction. Spatial resolution with True X reconstruction was improved by 45 % and its % contrast was significantly improved compared to those with the conventional OSEM without PSF modeling reconstruction algorithm. The noise level was higher than that with the other reconstruction algorithm. Therefore, True X reconstruction should be used with caution when quantifying PET data.

  7. A new reconstruction strategy for image improvement in pinhole SPECT

    International Nuclear Information System (INIS)

    Zeniya, Tsutomu; Watabe, Hiroshi; Kim, Kyeong Min; Teramoto, Noboru; Hayashi, Takuya; Iida, Hidehiro; Aoi, Toshiyuki; Sohlberg, Antti; Kudo, Hiroyuki

    2004-01-01

    Pinhole single-photon emission computed tomography (SPECT) is able to provide information on the biodistribution of several radioligands in small laboratory animals, but has limitations associated with non-uniform spatial resolution or axial blurring. We have hypothesised that this blurring is due to incompleteness of the projection data acquired by a single circular pinhole orbit, and have evaluated a new strategy for accurate image reconstruction with better spatial resolution uniformity. A pinhole SPECT system using two circular orbits and a dedicated three-dimensional ordered subsets expectation maximisation (3D-OSEM) reconstruction method were developed. In this system, not the camera but the object rotates, and the two orbits are at 90 and 45 relative to the object's axis. This system satisfies Tuy's condition, and is thus able to provide complete data for 3D pinhole SPECT reconstruction within the whole field of view (FOV). To evaluate this system, a series of experiments was carried out using a multiple-disk phantom filled with 99m Tc solution. The feasibility of the proposed method for small animal imaging was tested with a mouse bone study using 99m Tc-hydroxymethylene diphosphonate. Feldkamp's filtered back-projection (FBP) method and the 3D-OSEM method were applied to these data sets, and the visual and statistical properties were examined. Axial blurring, which was still visible at the edge of the FOV even after applying the conventional 3D-OSEM instead of FBP for single-orbit data, was not visible after application of 3D-OSEM using two-orbit data. 3D-OSEM using two-orbit data dramatically reduced the resolution non-uniformity and statistical noise, and also demonstrated considerably better image quality in the mouse scan. This system may be of use in quantitative assessment of bio-physiological functions in small animals. (orig.)

  8. Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

    International Nuclear Information System (INIS)

    Tricarico, Francesco; Hlavacek, Anthony M.; Schoepf, U.J.; Ebersberger, Ullrich; Nance, John W.; Vliegenthart, Rozemarijn; Cho, Young Jun; Spears, J.R.; Secchi, Francesco; Savino, Giancarlo; Marano, Riccardo; Bonomo, Lorenzo; Schoenberg, Stefan O.; Apfaltrer, Paul

    2013-01-01

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. (orig.)

  9. Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Tricarico, Francesco [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Catholic University of the Sacred Heart, ' ' A. Gemelli' ' Hospital, Department of Bioimaging and Radiological Sciences, Rome (Italy); Hlavacek, Anthony M. [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Children' s Hospital, Medical University of South Carolina, Division of Pediatric Cardiology, Charleston, SC (United States); Schoepf, U.J. [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Children' s Hospital, Medical University of South Carolina, Division of Pediatric Cardiology, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Ebersberger, Ullrich [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Heart Centre Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany); Nance, John W. [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Johns Hopkins Hospital, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Vliegenthart, Rozemarijn [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); University Medical Centre Groningen/University of Groningen, Centre for Medical Imaging - North East Netherlands, Department of Radiology, Groningen (Netherlands); Cho, Young Jun [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Konyang University School of Medicine, Department of Radiology, Daejeon (Korea, Republic of); Spears, J.R. [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Secchi, Francesco [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Milan School of Medicine IRCCS Policlinico San Donato, Department of Medical and Surgical Sciences, Radiology Unit, Milan (Italy); Savino, Giancarlo; Marano, Riccardo; Bonomo, Lorenzo [Catholic University of the Sacred Heart, ' ' A. Gemelli' ' Hospital, Department of Bioimaging and Radiological Sciences, Rome (Italy); Schoenberg, Stefan O. [University Medical Centre Mannheim, Medical Faculty Mannheim - Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany); Apfaltrer, Paul [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); University Medical Centre Mannheim, Medical Faculty Mannheim - Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany)

    2013-05-15

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. (orig.)

  10. Quality improvement through multiple response optimization

    International Nuclear Information System (INIS)

    Noorossana, R.; Alemzad, H.

    2003-01-01

    The performance of a product is often evaluated by several quality characteristics. Optimizing the manufacturing process with respect to only one quality characteristic will not always lead to the optimum values for other characteristics. Hence, it would be desirable to improve the overall quality of a product by improving quality characteristics, which are considered to be important. The problem consists of optimizing several responses using multiple objective decision making approach and design of experiments. A case study will be discussed to show the application of the proposal method

  11. Power theories for improved power quality

    CERN Document Server

    Pasko, Marian

    2012-01-01

    Power quality describes a set of parameters of electric power and the load’s ability to function properly under specific conditions. It is estimated that problems relating to power quality costs the European industry hundreds of billions of Euros annually. In contrast, financing for the prevention of these problems amount to fragments of these costs. Power Theories for Improved Power Quality addresses this imbalance by presenting and assessing a range of methods and problems related to improving the quality of electric power supply. Focusing particularly on active compensators and the DSP based control algorithms, Power Theories for Improved Power Quality introduces the fundamental problems of electrical power. This introduction is followed by chapters which discuss: •‘Power theories’ including their historical development and application to practical problems, •operational principles of active compensator’s DSP control based algorithms using examples and results from laboratory research, and •t...

  12. Model-based Iterative Reconstruction: Effect on Patient Radiation Dose and Image Quality in Pediatric Body CT

    Science.gov (United States)

    Dillman, Jonathan R.; Goodsitt, Mitchell M.; Christodoulou, Emmanuel G.; Keshavarzi, Nahid; Strouse, Peter J.

    2014-01-01

    Purpose To retrospectively compare image quality and radiation dose between a reduced-dose computed tomographic (CT) protocol that uses model-based iterative reconstruction (MBIR) and a standard-dose CT protocol that uses 30% adaptive statistical iterative reconstruction (ASIR) with filtered back projection. Materials and Methods Institutional review board approval was obtained. Clinical CT images of the chest, abdomen, and pelvis obtained with a reduced-dose protocol were identified. Images were reconstructed with two algorithms: MBIR and 100% ASIR. All subjects had undergone standard-dose CT within the prior year, and the images were reconstructed with 30% ASIR. Reduced- and standard-dose images were evaluated objectively and subjectively. Reduced-dose images were evaluated for lesion detectability. Spatial resolution was assessed in a phantom. Radiation dose was estimated by using volumetric CT dose index (CTDIvol) and calculated size-specific dose estimates (SSDE). A combination of descriptive statistics, analysis of variance, and t tests was used for statistical analysis. Results In the 25 patients who underwent the reduced-dose protocol, mean decrease in CTDIvol was 46% (range, 19%–65%) and mean decrease in SSDE was 44% (range, 19%–64%). Reduced-dose MBIR images had less noise (P > .004). Spatial resolution was superior for reduced-dose MBIR images. Reduced-dose MBIR images were equivalent to standard-dose images for lungs and soft tissues (P > .05) but were inferior for bones (P = .004). Reduced-dose 100% ASIR images were inferior for soft tissues (P ASIR. Conclusion CT performed with a reduced-dose protocol and MBIR is feasible in the pediatric population, and it maintains diagnostic quality. © RSNA, 2013 Online supplemental material is available for this article. PMID:24091359

  13. A Superresolution Image Reconstruction Algorithm Based on Landweber in Electrical Capacitance Tomography

    Directory of Open Access Journals (Sweden)

    Chen Deyun

    2013-01-01

    Full Text Available According to the image reconstruction accuracy influenced by the “soft field” nature and ill-conditioned problems in electrical capacitance tomography, a superresolution image reconstruction algorithm based on Landweber is proposed in the paper, which is based on the working principle of the electrical capacitance tomography system. The method uses the algorithm which is derived by regularization of solutions derived and derives closed solution by fast Fourier transform of the convolution kernel. So, it ensures the certainty of the solution and improves the stability and quality of image reconstruction results. Simulation results show that the imaging precision and real-time imaging of the algorithm are better than Landweber algorithm, and this algorithm proposes a new method for the electrical capacitance tomography image reconstruction algorithm.

  14. Scan time reduction in {sup 23}Na-Magnetic Resonance Imaging using the chemical shift imaging sequence. Evaluation of an iterative reconstruction method

    Energy Technology Data Exchange (ETDEWEB)

    Weingaertner, Sebastian; Konstandin, Simon; Schad, Lothar R. [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine; Wetterling, Friedrich [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine; Dublin Univ. (Ireland) Trinity Inst. of Neuroscience; Fatar, Marc [Heidelberg Univ., Mannheim (Germany). Dept. of Neurology; Neumaier-Probst, Eva [Heidelberg Univ., Mannheim (Germany). Dept. of Neuroradiology

    2015-07-01

    To evaluate potential scan time reduction in {sup 23}Na-Magnetic Resonance Imaging with the chemical shift imaging sequence (CSI) using undersampled data of high-quality datasets, reconstructed with an iterative constrained reconstruction, compared to reduced resolution or reduced signal-to-noise ratio. CSI {sup 23}Na-images were retrospectively undersampled and reconstructed with a constrained reconstruction scheme. The results were compared to conventional methods of scan time reduction. The constrained reconstruction scheme used a phase constraint and a finite object support, which was extracted from a spatially registered {sup 1}H-image acquired with a double-tuned coil. The methods were evaluated using numerical simulations, phantom images and in-vivo images of a healthy volunteer and a patient who suffered from cerebral ischemic stroke. The constrained reconstruction scheme showed improved image quality compared to a decreased number of averages, images with decreased resolution or circular undersampling with weighted averaging for any undersampling factor. Brain images of a stroke patient, which were reconstructed from three-fold undersampled k-space data, resulted in only minor differences from the original image (normalized root means square error < 12%) and an almost identical delineation of the stroke region (mismatch < 6%). The acquisition of undersampled {sup 23}Na-CSI images enables up to three-fold scan time reduction with improved image quality compared to conventional methods of scan time saving.

  15. Improvement of electrolaryngeal speech quality using a supraglottal voice source with compensation of vocal tract characteristics.

    Science.gov (United States)

    Wu, Liang; Wan, Congying; Wang, Supin; Wan, Mingxi

    2013-07-01

    Electrolarynx (EL) is a medical speech-recovery device designed for patients who have lost their original voice box due to laryngeal cancer. As a substitute for human larynx, the current commercial EL voice source cannot reconstruct natural EL speech under laryngectomy conditions. To eliminate the abnormal acoustic properties of EL speech, a supraglottal voice source with compensation of vocal tract characteristics was proposed and provided through an experimental EL(SGVS-EL) system. The acoustic analyses of simulated EL speech and reconstructed EL speech produced with different voice sources were performed in the normal subject and laryngectomee. The results indicated that the supraglottal voice source was successful in improving the acoustic properties of EL speech by enhancing low- frequency energy, correcting the shifted formants to normal range, and eliminating the visible spectral zeros. Both normal subject and laryngectomee also produced more natural vowels using SGVS-EL than commercial EL, even if the vocal tract parameter was substituted and the supraglottal voice source was biased to a certain degree. Therefore, supraglottal voice source is a feasible and effective approach to improving the acoustic quality of EL speech.

  16. Modelling the physics in iterative reconstruction for transmission computed tomography

    Science.gov (United States)

    Nuyts, Johan; De Man, Bruno; Fessler, Jeffrey A.; Zbijewski, Wojciech; Beekman, Freek J.

    2013-01-01

    There is an increasing interest in iterative reconstruction (IR) as a key tool to improve quality and increase applicability of X-ray CT imaging. IR has the ability to significantly reduce patient dose, it provides the flexibility to reconstruct images from arbitrary X-ray system geometries and it allows to include detailed models of photon transport and detection physics, to accurately correct for a wide variety of image degrading effects. This paper reviews discretisation issues and modelling of finite spatial resolution, Compton scatter in the scanned object, data noise and the energy spectrum. Widespread implementation of IR with highly accurate model-based correction, however, still requires significant effort. In addition, new hardware will provide new opportunities and challenges to improve CT with new modelling. PMID:23739261

  17. Research of the system response of neutron double scatter imaging for MLEM reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, M., E-mail: wyj2013@163.com [Northwest Institute of Nuclear Technology, Xi’an 710024 (China); State Key Laboratory of Intense Pulsed Radiation-Simulation and Effect, Xi’an 710024 (China); Peng, B.D.; Sheng, L.; Li, K.N.; Zhang, X.P.; Li, Y.; Li, B.K.; Yuan, Y.; Wang, P.W.; Zhang, X.D.; Li, C.H. [Northwest Institute of Nuclear Technology, Xi’an 710024 (China); State Key Laboratory of Intense Pulsed Radiation-Simulation and Effect, Xi’an 710024 (China)

    2015-03-01

    A Maximum Likelihood image reconstruction technique has been applied to neutron scatter imaging. The response function of the imaging system can be obtained by Monte Carlo simulation, which is very time-consuming if the number of image pixels and particles is large. In this work, to improve time efficiency, an analytical approach based on the probability of neutron interaction and transport in the detector is developed to calculate the system response function. The response function was applied to calculate the relative efficiency of the neutron scatter imaging system as a function of the incident neutron energy. The calculated results agreed with simulations by the MCNP5 software. Then the maximum likelihood expectation maximization (MLEM) reconstruction method with the system response function was used to reconstruct data simulated by Monte Carlo method. The results showed that there was good consistency between the reconstruction position and true position. Compared with back-projection reconstruction, the improvement in image quality was obvious, and the locations could be discerned easily for multiple radiation point sources.

  18. An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering

    Directory of Open Access Journals (Sweden)

    Ming Yan

    2006-01-01

    Full Text Available FDK algorithm is a well-known 3D (three-dimensional approximate algorithm for CT (computed tomography image reconstruction and is also known to suffer from considerable artifacts when the scanning cone angle is large. Recently, it has been improved by performing the ramp filtering along the tangential direction of the X-ray source helix for dealing with the large cone angle problem. In this paper, we present an FDK-type approximate reconstruction algorithm for gantry-tilted CT imaging. The proposed method improves the image reconstruction by filtering the projection data along a proper direction which is determined by CT parameters and gantry-tilted angle. As a result, the proposed algorithm for gantry-tilted CT reconstruction can provide more scanning flexibilities in clinical CT scanning and is efficient in computation. The performance of the proposed algorithm is evaluated with turbell clock phantom and thorax phantom and compared with FDK algorithm and a popular 2D (two-dimensional approximate algorithm. The results show that the proposed algorithm can achieve better image quality for gantry-tilted CT image reconstruction.

  19. Improved specimen reconstruction by Hilbert phase contrast tomography.

    Science.gov (United States)

    Barton, Bastian; Joos, Friederike; Schröder, Rasmus R

    2008-11-01

    The low signal-to-noise ratio (SNR) in images of unstained specimens recorded with conventional defocus phase contrast makes it difficult to interpret 3D volumes obtained by electron tomography (ET). The high defocus applied for conventional tilt series generates some phase contrast but leads to an incomplete transfer of object information. For tomography of biological weak-phase objects, optimal image contrast and subsequently an optimized SNR are essential for the reconstruction of details such as macromolecular assemblies at molecular resolution. The problem of low contrast can be partially solved by applying a Hilbert phase plate positioned in the back focal plane (BFP) of the objective lens while recording images in Gaussian focus. Images recorded with the Hilbert phase plate provide optimized positive phase contrast at low spatial frequencies, and the contrast transfer in principle extends to the information limit of the microscope. The antisymmetric Hilbert phase contrast (HPC) can be numerically converted into isotropic contrast, which is equivalent to the contrast obtained by a Zernike phase plate. Thus, in-focus HPC provides optimal structure factor information without limiting effects of the transfer function. In this article, we present the first electron tomograms of biological specimens reconstructed from Hilbert phase plate image series. We outline the technical implementation of the phase plate and demonstrate that the technique is routinely applicable for tomography. A comparison between conventional defocus tomograms and in-focus HPC volumes shows an enhanced SNR and an improved specimen visibility for in-focus Hilbert tomography.

  20. Preanalytical quality improvement : in quality we trust

    OpenAIRE

    Lippi, Giuseppe; Becan-McBride, Kathleen; Behulova, Darina; Bowen, Raffick A.; Church, Stephen; Delanghe, Joris; Grankvist, Kjell; Kitchen, Steve; Nybo, Mads; Nauck, Matthias; Nikolac, Nora; Palicka, Vladimir; Plebani, Mario; Sandberg, Sverre; Simundic, Ana-Maria

    2013-01-01

    Total quality in laboratory medicine should be defined as the guarantee that each activity throughout the total testing process is correctly performed, providing valuable medical decision-making and effective patient care. In the past decades, a 10-fold reduction in the analytical error rate has been achieved thanks to improvements in both reliability and standardization of analytical techniques, reagents, and instrumentation. Notable advances in information technology, quality control and qu...

  1. Which Breast Is the Best? Successful Autologous or Alloplastic Breast Reconstruction : Patient-Reported Quality-of-Life Outcomes

    NARCIS (Netherlands)

    Eltahir, Yassir; Werners, Lisanne L. C. H.; Dreise, Marieke M.; Zeiffmans van Emmichoven, Ingeborg A.; Werker, Paul M. N.; de Bock, Geertruida H.

    Background: Breast reconstruction is an appropriate option offered to women who are diagnosed with breast cancer or gene mutations. It may be accomplished with implants or autologous procedures. This cross-sectional study evaluated the satisfaction and quality of life in addition to complications

  2. Dose and image quality in low-dose CT for urinary stone disease: added value of automatic tube current modulation and iterative reconstruction techniques

    International Nuclear Information System (INIS)

    Soenen, Olivier; Balliauw, Christophe; Oyen, Raymond; Zanca, Federica

    2017-01-01

    The aim of this study was to compare dose and image quality (IQ) of a baseline low-dose computed tomography (CT) (fix mAs) vs. an ultra-low-dose CT (automatic tube current modulation, ATCM) in patients with suspected urinary stone disease and to assess the added value of iterative reconstruction. CT examination was performed on 193 patients (103 baseline low-dose, 90 ultra-low-dose). Filtered back projection (FBP) was used for both protocols, and Sinogram Affirmed Iterative Reconstruction (SAFIRE) was used for the ultra-low-dose protocol only. Dose and ureter stones information were collected for both protocols. Subjective IQ was assessed by two radiologists scoring noise, visibility of the ureter and overall IQ. Objective IQ (contrast-to-noise ratio, CNR) was assessed for the ultra-low-dose protocol only (FBP and SAFIRE). The ultra-low-dose protocol (ATCM) showed a 22% decrease in mean effective dose ( p < 0.001) and improved visibility of the pelvic ureter (p = 0.02). CNR was higher for SAFIRE (p < 0.0001). SAFIRE improves the objective IQ, but not the subjective IQ for the chosen clinical task. (authors)

  3. Three-dimensional digital tomosynthesis iterative reconstruction, artifact reduction and alternative acquisition geometry

    CERN Document Server

    Levakhina, Yulia

    2014-01-01

    Yulia Levakhina gives an introduction to the major challenges of image reconstruction in Digital Tomosynthesis (DT), particularly to the connection of the reconstruction problem with the incompleteness of the DT dataset. The author discusses the factors which cause the formation of limited angle artifacts and proposes how to account for them in order to improve image quality and axial resolution of modern DT. The addressed methods include a weighted non-linear back projection scheme for algebraic reconstruction and?novel dual-axis acquisition geometry. All discussed algorithms and methods are supplemented by detailed illustrations, hints for practical implementation, pseudo-code, simulation results and real patient case examples.

  4. Use of model-based iterative reconstruction (MBIR) in reduced-dose CT for routine follow-up of patients with malignant lymphoma: dose savings, image quality and phantom study

    International Nuclear Information System (INIS)

    Herin, Edouard; Chiaradia, Melanie; Cavet, Madeleine; Deux, Jean-Francois; Rahmouni, Alain; Gardavaud, Francois; Beaussart, Pauline; Richard, Philippe; Haioun, Corinne; Itti, Emmanuel; Luciani, Alain

    2015-01-01

    To evaluate both in vivo and in phantom studies, dose reduction, and image quality of body CT reconstructed with model-based iterative reconstruction (MBIR), performed during patient follow-ups for lymphoma. This study included 40 patients (mean age 49 years) with lymphoma. All underwent reduced-dose CT during follow-up, reconstructed using MBIR or 50 % advanced statistical iterative reconstruction (ASIR). All had previously undergone a standard dose CT with filtered back projection (FBP) reconstruction. The volume CT dose index (CTDIvol), the density measures in liver, spleen, fat, air, and muscle, and the image quality (noise and signal to noise ratio, SNR) (ANOVA) observed using standard or reduced-dose CT were compared both in patients and a phantom study (Catphan 600) (Kruskal Wallis). The CTDIvol was decreased on reduced-dose body CT (4.06 mGy vs. 15.64 mGy p < 0.0001). SNR was higher in reduced-dose CT reconstructed with MBIR than in 50 % ASIR or than standard dose CT with FBP (patients, p ≤ 0.01; phantoms, p = 0.003). Low contrast detectability and spatial resolution in phantoms were not altered on MBIR-reconstructed CT (p ≥ 0.11). Reduced-dose CT with MBIR reconstruction can decrease radiation dose delivered to patients with lymphoma, while keeping an image quality similar to that obtained on standard-dose CT. (orig.)

  5. Use of model-based iterative reconstruction (MBIR) in reduced-dose CT for routine follow-up of patients with malignant lymphoma: dose savings, image quality and phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Herin, Edouard; Chiaradia, Melanie; Cavet, Madeleine; Deux, Jean-Francois; Rahmouni, Alain [AP-HP, Hopitaux Universitaires Henri Mondor, Imagerie Medicale, Creteil (France); Universite Paris Est Creteil, Faculte de Medecine, Creteil (France); Gardavaud, Francois; Beaussart, Pauline [AP-HP, Hopitaux Universitaires Henri Mondor, Imagerie Medicale, Creteil (France); Richard, Philippe [GE Healthcare France, Buc (France); Haioun, Corinne [Universite Paris Est Creteil, Faculte de Medecine, Creteil (France); AP-HP, Hopitaux Universitaires Henri Mondor, Hemopathies Lymphoides, Creteil (France); Itti, Emmanuel [Universite Paris Est Creteil, Faculte de Medecine, Creteil (France); AP-HP, Hopitaux Universitaires Henri Mondor, Medecine Nucleaire, Creteil (France); Luciani, Alain [AP-HP, Hopitaux Universitaires Henri Mondor, Imagerie Medicale, Creteil (France); Universite Paris Est Creteil, Faculte de Medecine, Creteil (France); INSERM Unite U 955, Creteil (France); AP-HP, Groupe Henri Mondor Albert Chenevier, Imagerie Medicale, CHU Henri Mondor, Creteil Cedex (France)

    2015-08-15

    To evaluate both in vivo and in phantom studies, dose reduction, and image quality of body CT reconstructed with model-based iterative reconstruction (MBIR), performed during patient follow-ups for lymphoma. This study included 40 patients (mean age 49 years) with lymphoma. All underwent reduced-dose CT during follow-up, reconstructed using MBIR or 50 % advanced statistical iterative reconstruction (ASIR). All had previously undergone a standard dose CT with filtered back projection (FBP) reconstruction. The volume CT dose index (CTDIvol), the density measures in liver, spleen, fat, air, and muscle, and the image quality (noise and signal to noise ratio, SNR) (ANOVA) observed using standard or reduced-dose CT were compared both in patients and a phantom study (Catphan 600) (Kruskal Wallis). The CTDIvol was decreased on reduced-dose body CT (4.06 mGy vs. 15.64 mGy p < 0.0001). SNR was higher in reduced-dose CT reconstructed with MBIR than in 50 % ASIR or than standard dose CT with FBP (patients, p ≤ 0.01; phantoms, p = 0.003). Low contrast detectability and spatial resolution in phantoms were not altered on MBIR-reconstructed CT (p ≥ 0.11). Reduced-dose CT with MBIR reconstruction can decrease radiation dose delivered to patients with lymphoma, while keeping an image quality similar to that obtained on standard-dose CT. (orig.)

  6. Quality improvement in pediatrics: past, present, and future.

    Science.gov (United States)

    Schwartz, Stephanie P; Rehder, Kyle J

    2017-01-01

    Almost two decades ago, the landmark report "To Err is Human" compelled healthcare to address the large numbers of hospitalized patients experiencing preventable harm. Concurrently, it became clear that the rapidly rising cost of healthcare would be unsustainable in the long-term. As a result, quality improvement methodologies initially rooted in other high-reliability industries have become a primary focus of healthcare. Multiple pediatric studies demonstrate remarkable quality and safety improvements in several domains including handoffs, catheter-associated blood stream infections, and other serious safety events. While both quality improvement and research are data-driven processes, significant differences exist between the two. Research utilizes a hypothesis driven approach to obtain new knowledge while quality improvement often incorporates a cyclic approach to translate existing knowledge into clinical practice. Recent publications have provided guidelines and methods for effectively reporting quality and safety work and improvement implementations. This review examines not only how quality improvement in pediatrics has led to improved outcomes, but also looks to the future of quality improvement in healthcare with focus on education and collaboration to ensure best practice approaches to caring for children.

  7. [Assessment of the quality of life of oral cancer patients after reconstruction with free anterolateral thigh perforator flaps].

    Science.gov (United States)

    Na, Deng; Wei, He; Rui, Li; Wenlu, Li; Ning, Gao; Wen, Zhang

    2015-04-01

    This study aims to evaluate the quality of life (QOL) of patients who underwent resection of oral cancer and reconstruction by free anierolateral thigh perforator flaps (ALTF). A total of 32 patients with oral and maxillofacial malignancies who had undergone the resection of oral cancer and reconstruction by ALTF were retrospectively analyzed. At 12 months postoperatively, the QOL of these patients was assessed by using the 14-item oral health impact profile (OHIP-14) and the medical outcome study short form-36 (SF-36) questionnaires. A total of 32 questionnaires were collected. In SF-36, the highest scoring domains were bodily pain (78.58 ± 14.82), physical functioning (72.08 ± 27.86), and the role of physical (60.00 ± 42.63), whereas the lowest scoring domains were role-emotional (41.67 ± 39.62), followed by mental health (50.75 ± 13.07) and health transition (54.17 ± 21.75). In OHIP-14, the lowest scoring domains were social disability (34.50 ± 11.32) and handicap (36.04 ± 12.05), indicating the functional recovery was better; and the highest scoring domains were physical pain (73.50 ± 18.96) and psychological discomfort (60.17 ± 20.66), indicating the functional recovery was worse. The ALTF is an ideal selection for the reconstruction of oral defects after cancer resection. In using this flap, the basic social need of patients after surgery can be satisfied. Moreover, the appearance and the functions of chewing, deglutition, and speech can be restored in varying degrees. Thus, ALTF can improve the patients' QOL.

  8. Assessing image quality and dose reduction of a new x-ray computed tomography iterative reconstruction algorithm using model observers

    International Nuclear Information System (INIS)

    Tseng, Hsin-Wu; Kupinski, Matthew A.; Fan, Jiahua; Sainath, Paavana; Hsieh, Jiang

    2014-01-01

    Purpose: A number of different techniques have been developed to reduce radiation dose in x-ray computed tomography (CT) imaging. In this paper, the authors will compare task-based measures of image quality of CT images reconstructed by two algorithms: conventional filtered back projection (FBP), and a new iterative reconstruction algorithm (IR). Methods: To assess image quality, the authors used the performance of a channelized Hotelling observer acting on reconstructed image slices. The selected channels are dense difference Gaussian channels (DDOG).A body phantom and a head phantom were imaged 50 times at different dose levels to obtain the data needed to assess image quality. The phantoms consisted of uniform backgrounds with low contrast signals embedded at various locations. The tasks the observer model performed included (1) detection of a signal of known location and shape, and (2) detection and localization of a signal of known shape. The employed DDOG channels are based on the response of the human visual system. Performance was assessed using the areas under ROC curves and areas under localization ROC curves. Results: For signal known exactly (SKE) and location unknown/signal shape known tasks with circular signals of different sizes and contrasts, the authors’ task-based measures showed that a FBP equivalent image quality can be achieved at lower dose levels using the IR algorithm. For the SKE case, the range of dose reduction is 50%–67% (head phantom) and 68%–82% (body phantom). For the study of location unknown/signal shape known, the dose reduction range can be reached at 67%–75% for head phantom and 67%–77% for body phantom case. These results suggest that the IR images at lower dose settings can reach the same image quality when compared to full dose conventional FBP images. Conclusions: The work presented provides an objective way to quantitatively assess the image quality of a newly introduced CT IR algorithm. The performance of the

  9. Novel Fourier-based iterative reconstruction for sparse fan projection using alternating direction total variation minimization

    International Nuclear Information System (INIS)

    Jin Zhao; Zhang Han-Ming; Yan Bin; Li Lei; Wang Lin-Yuan; Cai Ai-Long

    2016-01-01

    Sparse-view x-ray computed tomography (CT) imaging is an interesting topic in CT field and can efficiently decrease radiation dose. Compared with spatial reconstruction, a Fourier-based algorithm has advantages in reconstruction speed and memory usage. A novel Fourier-based iterative reconstruction technique that utilizes non-uniform fast Fourier transform (NUFFT) is presented in this work along with advanced total variation (TV) regularization for a fan sparse-view CT. The proposition of a selective matrix contributes to improve reconstruction quality. The new method employs the NUFFT and its adjoin to iterate back and forth between the Fourier and image space. The performance of the proposed algorithm is demonstrated through a series of digital simulations and experimental phantom studies. Results of the proposed algorithm are compared with those of existing TV-regularized techniques based on compressed sensing method, as well as basic algebraic reconstruction technique. Compared with the existing TV-regularized techniques, the proposed Fourier-based technique significantly improves convergence rate and reduces memory allocation, respectively. (paper)

  10. WE-FG-207B-02: Material Reconstruction for Spectral Computed Tomography with Detector Response Function

    International Nuclear Information System (INIS)

    Liu, J; Gao, H

    2016-01-01

    Purpose: Different from the conventional computed tomography (CT), spectral CT based on energy-resolved photon-counting detectors is able to provide the unprecedented material composition. However, an important missing piece for accurate spectral CT is to incorporate the detector response function (DRF), which is distorted by factors such as pulse pileup and charge-sharing. In this work, we propose material reconstruction methods for spectral CT with DRF. Methods: The polyenergetic X-ray forward model takes the DRF into account for accurate material reconstruction. Two image reconstruction methods are proposed: a direct method based on the nonlinear data fidelity from DRF-based forward model; a linear-data-fidelity based method that relies on the spectral rebinning so that the corresponding DRF matrix is invertible. Then the image reconstruction problem is regularized with the isotropic TV term and solved by alternating direction method of multipliers. Results: The simulation results suggest that the proposed methods provided more accurate material compositions than the standard method without DRF. Moreover, the proposed method with linear data fidelity had improved reconstruction quality from the proposed method with nonlinear data fidelity. Conclusion: We have proposed material reconstruction methods for spectral CT with DRF, whichprovided more accurate material compositions than the standard methods without DRF. Moreover, the proposed method with linear data fidelity had improved reconstruction quality from the proposed method with nonlinear data fidelity. Jiulong Liu and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000), and the Shanghai Pujiang Talent Program (#14PJ1404500).

  11. STEP: Self-supporting tailored k-space estimation for parallel imaging reconstruction.

    Science.gov (United States)

    Zhou, Zechen; Wang, Jinnan; Balu, Niranjan; Li, Rui; Yuan, Chun

    2016-02-01

    A new subspace-based iterative reconstruction method, termed Self-supporting Tailored k-space Estimation for Parallel imaging reconstruction (STEP), is presented and evaluated in comparison to the existing autocalibrating method SPIRiT and calibrationless method SAKE. In STEP, two tailored schemes including k-space partition and basis selection are proposed to promote spatially variant signal subspace and incorporated into a self-supporting structured low rank model to enforce properties of locality, sparsity, and rank deficiency, which can be formulated into a constrained optimization problem and solved by an iterative algorithm. Simulated and in vivo datasets were used to investigate the performance of STEP in terms of overall image quality and detail structure preservation. The advantage of STEP on image quality is demonstrated by retrospectively undersampled multichannel Cartesian data with various patterns. Compared with SPIRiT and SAKE, STEP can provide more accurate reconstruction images with less residual aliasing artifacts and reduced noise amplification in simulation and in vivo experiments. In addition, STEP has the capability of combining compressed sensing with arbitrary sampling trajectory. Using k-space partition and basis selection can further improve the performance of parallel imaging reconstruction with or without calibration signals. © 2015 Wiley Periodicals, Inc.

  12. Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Eck, Brendan L.; Fahmi, Rachid; Miao, Jun [Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Brown, Kevin M.; Zabic, Stanislav; Raihani, Nilgoun [Philips Healthcare, Cleveland, Ohio 44143 (United States); Wilson, David L., E-mail: dlw@case.edu [Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106 and Department of Radiology, Case Western Reserve University, Cleveland, Ohio 44106 (United States)

    2015-10-15

    Purpose: Aims in this study are to (1) develop a computational model observer which reliably tracks the detectability of human observers in low dose computed tomography (CT) images reconstructed with knowledge-based iterative reconstruction (IMR™, Philips Healthcare) and filtered back projection (FBP) across a range of independent variables, (2) use the model to evaluate detectability trends across reconstructions and make predictions of human observer detectability, and (3) perform human observer studies based on model predictions to demonstrate applications of the model in CT imaging. Methods: Detectability (d′) was evaluated in phantom studies across a range of conditions. Images were generated using a numerical CT simulator. Trained observers performed 4-alternative forced choice (4-AFC) experiments across dose (1.3, 2.7, 4.0 mGy), pin size (4, 6, 8 mm), contrast (0.3%, 0.5%, 1.0%), and reconstruction (FBP, IMR), at fixed display window. A five-channel Laguerre–Gauss channelized Hotelling observer (CHO) was developed with internal noise added to the decision variable and/or to channel outputs, creating six different internal noise models. Semianalytic internal noise computation was tested against Monte Carlo and used to accelerate internal noise parameter optimization. Model parameters were estimated from all experiments at once using maximum likelihood on the probability correct, P{sub C}. Akaike information criterion (AIC) was used to compare models of different orders. The best model was selected according to AIC and used to predict detectability in blended FBP-IMR images, analyze trends in IMR detectability improvements, and predict dose savings with IMR. Predicted dose savings were compared against 4-AFC study results using physical CT phantom images. Results: Detection in IMR was greater than FBP in all tested conditions. The CHO with internal noise proportional to channel output standard deviations, Model-k4, showed the best trade-off between fit

  13. WE-G-18A-04: 3D Dictionary Learning Based Statistical Iterative Reconstruction for Low-Dose Cone Beam CT Imaging

    International Nuclear Information System (INIS)

    Bai, T; Yan, H; Shi, F; Jia, X; Jiang, Steve B.; Lou, Y; Xu, Q; Mou, X

    2014-01-01

    Purpose: To develop a 3D dictionary learning based statistical reconstruction algorithm on graphic processing units (GPU), to improve the quality of low-dose cone beam CT (CBCT) imaging with high efficiency. Methods: A 3D dictionary containing 256 small volumes (atoms) of 3x3x3 voxels was trained from a high quality volume image. During reconstruction, we utilized a Cholesky decomposition based orthogonal matching pursuit algorithm to find a sparse representation on this dictionary basis of each patch in the reconstructed image, in order to regularize the image quality. To accelerate the time-consuming sparse coding in the 3D case, we implemented our algorithm in a parallel fashion by taking advantage of the tremendous computational power of GPU. Evaluations are performed based on a head-neck patient case. FDK reconstruction with full dataset of 364 projections is used as the reference. We compared the proposed 3D dictionary learning based method with a tight frame (TF) based one using a subset data of 121 projections. The image qualities under different resolutions in z-direction, with or without statistical weighting are also studied. Results: Compared to the TF-based CBCT reconstruction, our experiments indicated that 3D dictionary learning based CBCT reconstruction is able to recover finer structures, to remove more streaking artifacts, and is less susceptible to blocky artifacts. It is also observed that statistical reconstruction approach is sensitive to inconsistency between the forward and backward projection operations in parallel computing. Using high a spatial resolution along z direction helps improving the algorithm robustness. Conclusion: 3D dictionary learning based CBCT reconstruction algorithm is able to sense the structural information while suppressing noise, and hence to achieve high quality reconstruction. The GPU realization of the whole algorithm offers a significant efficiency enhancement, making this algorithm more feasible for potential

  14. WE-G-18A-04: 3D Dictionary Learning Based Statistical Iterative Reconstruction for Low-Dose Cone Beam CT Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bai, T [Xi' an Jiaotong University, Xi' an (China); UT Southwestern Medical Center, Dallas, TX (United States); Yan, H; Shi, F; Jia, X; Jiang, Steve B. [UT Southwestern Medical Center, Dallas, TX (United States); Lou, Y [University of California Irvine, Irvine, CA (United States); Xu, Q; Mou, X [Xi' an Jiaotong University, Xi' an (China)

    2014-06-15

    Purpose: To develop a 3D dictionary learning based statistical reconstruction algorithm on graphic processing units (GPU), to improve the quality of low-dose cone beam CT (CBCT) imaging with high efficiency. Methods: A 3D dictionary containing 256 small volumes (atoms) of 3x3x3 voxels was trained from a high quality volume image. During reconstruction, we utilized a Cholesky decomposition based orthogonal matching pursuit algorithm to find a sparse representation on this dictionary basis of each patch in the reconstructed image, in order to regularize the image quality. To accelerate the time-consuming sparse coding in the 3D case, we implemented our algorithm in a parallel fashion by taking advantage of the tremendous computational power of GPU. Evaluations are performed based on a head-neck patient case. FDK reconstruction with full dataset of 364 projections is used as the reference. We compared the proposed 3D dictionary learning based method with a tight frame (TF) based one using a subset data of 121 projections. The image qualities under different resolutions in z-direction, with or without statistical weighting are also studied. Results: Compared to the TF-based CBCT reconstruction, our experiments indicated that 3D dictionary learning based CBCT reconstruction is able to recover finer structures, to remove more streaking artifacts, and is less susceptible to blocky artifacts. It is also observed that statistical reconstruction approach is sensitive to inconsistency between the forward and backward projection operations in parallel computing. Using high a spatial resolution along z direction helps improving the algorithm robustness. Conclusion: 3D dictionary learning based CBCT reconstruction algorithm is able to sense the structural information while suppressing noise, and hence to achieve high quality reconstruction. The GPU realization of the whole algorithm offers a significant efficiency enhancement, making this algorithm more feasible for potential

  15. Sample selection based on kernel-subclustering for the signal reconstruction of multifunctional sensors

    International Nuclear Information System (INIS)

    Wang, Xin; Wei, Guo; Sun, Jinwei

    2013-01-01

    The signal reconstruction methods based on inverse modeling for the signal reconstruction of multifunctional sensors have been widely studied in recent years. To improve the accuracy, the reconstruction methods have become more and more complicated because of the increase in the model parameters and sample points. However, there is another factor that affects the reconstruction accuracy, the position of the sample points, which has not been studied. A reasonable selection of the sample points could improve the signal reconstruction quality in at least two ways: improved accuracy with the same number of sample points or the same accuracy obtained with a smaller number of sample points. Both ways are valuable for improving the accuracy and decreasing the workload, especially for large batches of multifunctional sensors. In this paper, we propose a sample selection method based on kernel-subclustering distill groupings of the sample data and produce the representation of the data set for inverse modeling. The method calculates the distance between two data points based on the kernel-induced distance instead of the conventional distance. The kernel function is a generalization of the distance metric by mapping the data that are non-separable in the original space into homogeneous groups in the high-dimensional space. The method obtained the best results compared with the other three methods in the simulation. (paper)

  16. Faithful reconstruction of digital holograms captured by FINCH using a Hamming window function in the Fresnel propagation.

    Science.gov (United States)

    Siegel, Nisan; Rosen, Joseph; Brooker, Gary

    2013-10-01

    Recent advances in Fresnel incoherent correlation holography (FINCH) increase the signal-to-noise ratio in hologram recording by interference of images from two diffractive lenses with focal lengths close to the image plane. Holograms requiring short reconstruction distances are created that reconstruct poorly with existing Fresnel propagation methods. Here we show a dramatic improvement in reconstructed fluorescent images when a 2D Hamming window function substituted for the disk window typically used to bound the impulse response in the Fresnel propagation. Greatly improved image contrast and quality are shown for simulated and experimentally determined FINCH holograms using a 2D Hamming window without significant loss in lateral or axial resolution.

  17. SU-F-207-02: Use of Postmortem Subjects for Subjective Image Quality Assessment in Abdominal CT Protocols with Iterative Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Mench, A [Salem Hospital, Salem, OR (United States); Lipnharski, I; Carranza, C; Lamoureux, R; Smajdor, L; Cormack, B; Mohammed, T; Rill, L; Arreola, M [University of Florida, Gainesville, FL (United States); Sinclair, L [Oregon Health & Science University, Portland, OR (United States)

    2015-06-15

    Purpose: New radiation dose reduction technologies are emerging constantly in the medical imaging field. The latest of these technologies, iterative reconstruction (IR) in CT, presents the ability to reduce dose significantly and hence provides great opportunity for CT protocol optimization. However, without effective analysis of image quality, the reduction in radiation exposure becomes irrelevant. This work explores the use of postmortem subjects as an image quality assessment medium for protocol optimizations in abdominal CT. Methods: Three female postmortem subjects were scanned using the Abdomen-Pelvis (AP) protocol at reduced minimum tube current and target noise index (SD) settings of 12.5, 17.5, 20.0, and 25.0. Images were reconstructed using two strengths of iterative reconstruction. Radiologists and radiology residents from several subspecialties were asked to evaluate 8 AP image sets including the current facility default scan protocol and 7 scans with the parameters varied as listed above. Images were viewed in the soft tissue window and scored on a 3-point scale as acceptable, borderline acceptable, and unacceptable for diagnosis. The facility default AP scan was identified to the reviewer while the 7 remaining AP scans were randomized and de-identified of acquisition and reconstruction details. The observers were also asked to comment on the subjective image quality criteria they used for scoring images. This included visibility of specific anatomical structures and tissue textures. Results: Radiologists scored images as acceptable or borderline acceptable for target noise index settings of up to 20. Due to the postmortem subjects’ close representation of living human anatomy, readers were able to evaluate images as they would those of actual patients. Conclusion: Postmortem subjects have already been proven useful for direct CT organ dose measurements. This work illustrates the validity of their use for the crucial evaluation of image quality

  18. SU-F-207-02: Use of Postmortem Subjects for Subjective Image Quality Assessment in Abdominal CT Protocols with Iterative Reconstruction

    International Nuclear Information System (INIS)

    Mench, A; Lipnharski, I; Carranza, C; Lamoureux, R; Smajdor, L; Cormack, B; Mohammed, T; Rill, L; Arreola, M; Sinclair, L

    2015-01-01

    Purpose: New radiation dose reduction technologies are emerging constantly in the medical imaging field. The latest of these technologies, iterative reconstruction (IR) in CT, presents the ability to reduce dose significantly and hence provides great opportunity for CT protocol optimization. However, without effective analysis of image quality, the reduction in radiation exposure becomes irrelevant. This work explores the use of postmortem subjects as an image quality assessment medium for protocol optimizations in abdominal CT. Methods: Three female postmortem subjects were scanned using the Abdomen-Pelvis (AP) protocol at reduced minimum tube current and target noise index (SD) settings of 12.5, 17.5, 20.0, and 25.0. Images were reconstructed using two strengths of iterative reconstruction. Radiologists and radiology residents from several subspecialties were asked to evaluate 8 AP image sets including the current facility default scan protocol and 7 scans with the parameters varied as listed above. Images were viewed in the soft tissue window and scored on a 3-point scale as acceptable, borderline acceptable, and unacceptable for diagnosis. The facility default AP scan was identified to the reviewer while the 7 remaining AP scans were randomized and de-identified of acquisition and reconstruction details. The observers were also asked to comment on the subjective image quality criteria they used for scoring images. This included visibility of specific anatomical structures and tissue textures. Results: Radiologists scored images as acceptable or borderline acceptable for target noise index settings of up to 20. Due to the postmortem subjects’ close representation of living human anatomy, readers were able to evaluate images as they would those of actual patients. Conclusion: Postmortem subjects have already been proven useful for direct CT organ dose measurements. This work illustrates the validity of their use for the crucial evaluation of image quality

  19. The CMS Data Quality Monitoring software experience and future improvements

    CERN Document Server

    Batinkov, Atanas Ivanov

    2013-01-01

    The Data Quality Monitoring Software proved to be a central tool in the Compact Muon Solenoid experiment. Its flexibility allowed its integration in several environments: online, for real-time detector monitoring; offline, for the final, fine-grained data certification. The usage of the Data Quality Monitoring software in the different environments and its integration in the Compact Muon Solenoid reconstruction software framework and in all production workflows are presented. The main technical challenges and the adopted solutions to them will be also discussed with emphasis on functionality, long-term robustness and performance.

  20. Integration of quality improvement and cost-efficiency through industrial improvement techniques

    Directory of Open Access Journals (Sweden)

    Vink JP

    2016-06-01

    Full Text Available Jasper P Vink,1 Maxime T Rigaudy,1,2 Karl O Elmqvist11Imperial College Business School, Imperial College London, London, 2Hull York Medical School, York, UKIn this journal, Crema and Verbano1 discussed the importance of defining quality of health care and how quality can be improved through various industrial instruments and techniques. Quality of health care is a heavily debated topic that requires a wide scope of considerations across the many stakeholders of the health system. We acknowledge Crema and Verbano’s arguments that patient safety is a basic pillar of quality, upon which we would like to expand by highlighting the clinical effectiveness and patient-reported outcomes, which are the two further crucial components of quality. The arguments made regarding quality improvement techniques and cost efficiency in health care provision are insightful, yet appear to make a distinction between efforts to improve quality, eliminate waste from processes, and cut costs in health care provision. We would argue that in fact these achievements are all closely related and can be achieved simultaneously, if the industrial techniques of quality management are applied adequately.View the original paper by Crema and Verbano.

  1. An improved three-dimension reconstruction method based on guided filter and Delaunay

    Science.gov (United States)

    Liu, Yilin; Su, Xiu; Liang, Haitao; Xu, Huaiyuan; Wang, Yi; Chen, Xiaodong

    2018-01-01

    Binocular stereo vision is becoming a research hotspot in the area of image processing. Based on traditional adaptive-weight stereo matching algorithm, we improve the cost volume by averaging the AD (Absolute Difference) of RGB color channels and adding x-derivative of the grayscale image to get the cost volume. Then we use guided filter in the cost aggregation step and weighted median filter for post-processing to address the edge problem. In order to get the location in real space, we combine the deep information with the camera calibration to project each pixel in 2D image to 3D coordinate matrix. We add the concept of projection to region-growing algorithm for surface reconstruction, its specific operation is to project all the points to a 2D plane through the normals of clouds and return the results back to 3D space according to these connection relationship among the points in 2D plane. During the triangulation in 2D plane, we use Delaunay algorithm because it has optimal quality of mesh. We configure OpenCV and pcl on Visual Studio for testing, and the experimental results show that the proposed algorithm have higher computational accuracy of disparity and can realize the details of the real mesh model.

  2. The association between complications and quality of life after mastectomy and breast reconstruction for breast cancer.

    Science.gov (United States)

    Browne, John P; Jeevan, Ranjeet; Gulliver-Clarke, Carmel; Pereira, Jerome; Caddy, Christopher M; van der Meulen, Jan H P

    2017-09-15

    Medical treatment for breast cancer is associated with substantial toxicity and patient burden. There is less known about the impact of surgical complications. Understanding this impact could provide important information for patients when they are considering surgical options. Between 2008 and 2009, the UK National Mastectomy and Breast Reconstruction Audit recorded surgical complications for a prospective cohort of 17,844 women treated for breast cancer at 270 hospitals; 6405 of these women were surveyed about their quality of life 18 months after surgery. Breast appearance, emotional well-being, and physical well-being were quantified on 0- to 100-point scales. Linear multiple regression models, controlling for a range of baseline prognostic factors, were used to compare the scores of patients who had complications with the scores of those who did not. The overall complication rate was 10.2%. Complications were associated with little or no impairment in women undergoing mastectomy without reconstruction or with delayed reconstruction. The association was much larger for flap-related complications suffered during immediate reconstruction. The breast-appearance scores (adjusted mean difference, -23.8; 95% confidence interval [CI], -31.0 to -16.6) and emotional well-being scores (adjusted mean difference, -14.0; 95% CI, -22.0 to -6.0) of these patients were much lower than those of any other patient group. Implant-related complications were not associated with a lower quality of life in any surgical group. There is a strong case for prospectively collecting flap-complication rates at the surgeon and surgical unit level and for allowing patients to access these data when they make choices about their breast cancer surgery. Cancer 2017;123:3460-7. © 2017 American Cancer Society. © 2017 American Cancer Society.

  3. Recent advances in head and neck cancer reconstruction

    Directory of Open Access Journals (Sweden)

    Prabha Yadav

    2014-01-01

    Full Text Available Treatment of cancer is race against time! Following radical excision, breathing, speech, mastication and swallowing are hampered. Face is invariably involved. Beside functional normalcy, excellent cosmetic restoration is necessary for patient′s life quality. Primary wound healing, quick resumption of adequate oral intake, prompt initiation of chemo-radiotherapy has direct bearing on cure. Primary reconstruction with pedicle or free flap is the choice of treatment in most protocols. Composite defects are requiring bone, muscle and skin restrict choice of donor site and may have shortfalls in aesthetic and functional requirements. To improve further newer, and newer modalities are being developed and used to give best aesthetic and functions. Navigation, use of three-dimensional imaging, stereo lithic model and custom made implant for reconstruction are recommended as they promise improvement in aesthetics. Robotic surgeries allow access for resection of tumours and reconstruction with free flap in deep oropharynx obviating need of doing mandibulotomy. Researchers in stem cell and tissue engineering are looking forward to regenerating tissues and avoid the need of autologous tissue flaps. Desired tissue combination across counter may be available in the future. Excellent immunosuppressant drugs have made it possible to reconstruct composite facial anatomical units with allotransplant in a single surgery, along sensory and motor recovery! Mythological heterogenic head transplant like clone Ganesha, will be a reality in the near future!!

  4. Improving and monitoring air quality.

    Science.gov (United States)

    DuPont, André

    2018-05-01

    Since the authorization of the Clean Air Act Amendments of 1990, the air quality in the USA has significantly improved because of strong public support. The lessons learned over the last 25 years are being shared with the policy analysts, technical professionals, and scientist who endeavor to improve air quality in their communities. This paper will review how the USA has achieved the "high" standard of air quality that was envisioned in the early 1990s. This document will describe SO 2 gas emission reduction technology and highlight operation of emission monitoring technology. This paper describes the basic process operation of an air pollution control scrubber. A technical review of measures required to operate and maintain a large-scale pollution control system will be described. Also, the author explains how quality assurance procedures in performance of continuous emission monitoring plays a significant role in reducing air pollution.

  5. Protocol for the BRECAR study: a prospective cohort follow-up on the impact of breast reconstruction timing on health-related quality of life in women with breast cancer

    OpenAIRE

    Herrera de la Muela, Maria; García López, Enrique; Frías Aldeguer, Laura; Gómez-Campelo, Paloma

    2017-01-01

    Introduction The completion of postmastectomy breast reconstruction (BR) in women with breast cancer can last from months to years, and to our knowledge, there is a lack of studies that analyse how the different types and times of reconstruction impact on the patient’s quality of life and psychosocial adjustment. The primary aim of the BREast Cancer Reconstruction (BRECAR Study) is twofold. First, to describe health-related quality of life (HRQoL), overall satisfaction with surgery and psycho...

  6. [QUIPS: quality improvement in postoperative pain management].

    Science.gov (United States)

    Meissner, Winfried

    2011-01-01

    Despite the availability of high-quality guidelines and advanced pain management techniques acute postoperative pain management is still far from being satisfactory. The QUIPS (Quality Improvement in Postoperative Pain Management) project aims to improve treatment quality by means of standardised data acquisition, analysis of quality and process indicators, and feedback and benchmarking. During a pilot phase funded by the German Ministry of Health (BMG), a total of 12,389 data sets were collected from six participating hospitals. Outcome improved in four of the six hospitals. Process indicators, such as routine pain documentation, were only poorly correlated with outcomes. To date, more than 130 German hospitals use QUIPS as a routine quality management tool. An EC-funded parallel project disseminates the concept internationally. QUIPS demonstrates that patient-reported outcomes in postoperative pain management can be benchmarked in routine clinical practice. Quality improvement initiatives should use outcome instead of structural and process parameters. The concept is transferable to other fields of medicine. Copyright © 2011. Published by Elsevier GmbH.

  7. Techniques, clinical applications and limitations of 3D reconstruction in CT of the abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Maher, Michael M.; Kalra, Mannudeep K.; Sahani, Dushyant V.; Perumpillichira, James J.; Rizzo, Stephania; Saini, Sanjay; Mueller, Peter R. [Massachusetts General Hospital and Harvard Medical School, Boston (United States)

    2004-03-15

    Enhanced z-axis coverage with thin overlapping slices in breath-hold acquisitions with multidetector CT (MDCT) has considerably enhanced the quality of multiplanar 3D reconstruction. This pictorial essay describes the improvements in 3D reconstruction and technical aspects of 3D reconstruction and rendering techniques available for abdominal imaging. Clinical applications of 3D imaging in abdomen including liver, pancreaticobiliary system, urinary and gastrointestinal tracts and imaging before and after transplantation are discussed. In addition, this article briefly discusses the disadvantages of this-slice acquisitions including increasing numbers of transverse images, which must be reviewed by the radiologist.

  8. Techniques, clinical applications and limitations of 3D reconstruction in CT of the abdomen

    International Nuclear Information System (INIS)

    Maher, Michael M.; Kalra, Mannudeep K.; Sahani, Dushyant V.; Perumpillichira, James J.; Rizzo, Stephania; Saini, Sanjay; Mueller, Peter R.

    2004-01-01

    Enhanced z-axis coverage with thin overlapping slices in breath-hold acquisitions with multidetector CT (MDCT) has considerably enhanced the quality of multiplanar 3D reconstruction. This pictorial essay describes the improvements in 3D reconstruction and technical aspects of 3D reconstruction and rendering techniques available for abdominal imaging. Clinical applications of 3D imaging in abdomen including liver, pancreaticobiliary system, urinary and gastrointestinal tracts and imaging before and after transplantation are discussed. In addition, this article briefly discusses the disadvantages of this-slice acquisitions including increasing numbers of transverse images, which must be reviewed by the radiologist

  9. MR-guided joint reconstruction of activity and attenuation in brain PET-MR

    DEFF Research Database (Denmark)

    Mehranian, Abolfazl; Zaidi, Habib; Reader, Andrew J

    2017-01-01

    by unknown scaling factors. We recently demonstrated that in hybrid PET-MR, the scaling issue of this algorithm can be effectively addressed by imposing MR spatial constraints on the estimation of attenuation maps using a penalized MLAA (P-MLAA(+)) algorithm. With the advent of simultaneous PET-MR systems......, MRI-guided PET image reconstruction has also gained attention for improving the quantitative accuracy of PET images, usually degraded by noise and partial volume effects. The aim of this study is therefore to increase the benefits of MRI information for improving the quantitative accuracy of PET...... as a reference. The simulation results showed that the proposed method can notably improve the visual quality of the PET images by reducing noise while preserving structural boundaries and at the same time improving the quantitative accuracy of the PET images. Our clinical reconstruction results showed...

  10. Automated Reconstruction of Building LoDs from Airborne LiDAR Point Clouds Using an Improved Morphological Scale Space

    Directory of Open Access Journals (Sweden)

    Bisheng Yang

    2016-12-01

    Full Text Available Reconstructing building models at different levels of detail (LoDs from airborne laser scanning point clouds is urgently needed for wide application as this method can balance between the user’s requirements and economic costs. The previous methods reconstruct building LoDs from the finest 3D building models rather than from point clouds, resulting in heavy costs and inflexible adaptivity. The scale space is a sound theory for multi-scale representation of an object from a coarser level to a finer level. Therefore, this paper proposes a novel method to reconstruct buildings at different LoDs from airborne Light Detection and Ranging (LiDAR point clouds based on an improved morphological scale space. The proposed method first extracts building candidate regions following the separation of ground and non-ground points. For each building candidate region, the proposed method generates a scale space by iteratively using the improved morphological reconstruction with the increase of scale, and constructs the corresponding topological relationship graphs (TRGs across scales. Secondly, the proposed method robustly extracts building points by using features based on the TRG. Finally, the proposed method reconstructs each building at different LoDs according to the TRG. The experiments demonstrate that the proposed method robustly extracts the buildings with details (e.g., door eaves and roof furniture and illustrate good performance in distinguishing buildings from vegetation or other objects, while automatically reconstructing building LoDs from the finest building points.

  11. Wobbling and LSF-based maximum likelihood expectation maximization reconstruction for wobbling PET

    International Nuclear Information System (INIS)

    Kim, Hang-Keun; Son, Young-Don; Kwon, Dae-Hyuk; Joo, Yohan; Cho, Zang-Hee

    2016-01-01

    Positron emission tomography (PET) is a widely used imaging modality; however, the PET spatial resolution is not yet satisfactory for precise anatomical localization of molecular activities. Detector size is the most important factor because it determines the intrinsic resolution, which is approximately half of the detector size and determines the ultimate PET resolution. Detector size, however, cannot be made too small because both the decreased detection efficiency and the increased septal penetration effect degrade the image quality. A wobbling and line spread function (LSF)-based maximum likelihood expectation maximization (WL-MLEM) algorithm, which combined the MLEM iterative reconstruction algorithm with wobbled sampling and LSF-based deconvolution using the system matrix, was proposed for improving the spatial resolution of PET without reducing the scintillator or detector size. The new algorithm was evaluated using a simulation, and its performance was compared with that of the existing algorithms, such as conventional MLEM and LSF-based MLEM. Simulations demonstrated that the WL-MLEM algorithm yielded higher spatial resolution and image quality than the existing algorithms. The WL-MLEM algorithm with wobbling PET yielded substantially improved resolution compared with conventional algorithms with stationary PET. The algorithm can be easily extended to other iterative reconstruction algorithms, such as maximum a priori (MAP) and ordered subset expectation maximization (OSEM). The WL-MLEM algorithm with wobbling PET may offer improvements in both sensitivity and resolution, the two most sought-after features in PET design. - Highlights: • This paper proposed WL-MLEM algorithm for PET and demonstrated its performance. • WL-MLEM algorithm effectively combined wobbling and line spread function based MLEM. • WL-MLEM provided improvements in the spatial resolution and the PET image quality. • WL-MLEM can be easily extended to the other iterative

  12. Denoised ordered subset statistically penalized algebraic reconstruction technique (DOS-SPART) in digital breast tomosynthesis

    Science.gov (United States)

    Garrett, John; Li, Yinsheng; Li, Ke; Chen, Guang-Hong

    2017-03-01

    Digital breast tomosynthesis (DBT) is a three dimensional (3D) breast imaging modality in which projections are acquired over a limited angular span around the compressed breast and reconstructed into image slices parallel to the detector. DBT has been shown to help alleviate the breast tissue overlapping issues of two dimensional (2D) mammography. Since the overlapping tissues may simulate cancer masses or obscure true cancers, this improvement is critically important for improved breast cancer screening and diagnosis. In this work, a model-based image reconstruction method is presented to show that spatial resolution in DBT volumes can be maintained while dose is reduced using the presented method when compared to that of a state-of-the-art commercial reconstruction technique. Spatial resolution was measured in phantom images and subjectively in a clinical dataset. Noise characteristics were explored in a cadaver study. In both the quantitative and subjective results the image sharpness was maintained and overall image quality was maintained at reduced doses when the model-based iterative reconstruction was used to reconstruct the volumes.

  13. Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity.

    Science.gov (United States)

    Gong, Kuang; Cheng-Liao, Jinxiu; Wang, Guobao; Chen, Kevin T; Catana, Ciprian; Qi, Jinyi

    2018-04-01

    Positron emission tomography (PET) is a functional imaging modality widely used in oncology, cardiology, and neuroscience. It is highly sensitive, but suffers from relatively poor spatial resolution, as compared with anatomical imaging modalities, such as magnetic resonance imaging (MRI). With the recent development of combined PET/MR systems, we can improve the PET image quality by incorporating MR information into image reconstruction. Previously, kernel learning has been successfully embedded into static and dynamic PET image reconstruction using either PET temporal or MRI information. Here, we combine both PET temporal and MRI information adaptively to improve the quality of direct Patlak reconstruction. We examined different approaches to combine the PET and MRI information in kernel learning to address the issue of potential mismatches between MRI and PET signals. Computer simulations and hybrid real-patient data acquired on a simultaneous PET/MR scanner were used to evaluate the proposed methods. Results show that the method that combines PET temporal information and MRI spatial information adaptively based on the structure similarity index has the best performance in terms of noise reduction and resolution improvement.

  14. Effect of automated tube voltage selection, integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of 3rd generation dual-source aortic CT angiography: An intra-individual comparison.

    Science.gov (United States)

    Mangold, Stefanie; De Cecco, Carlo N; Wichmann, Julian L; Canstein, Christian; Varga-Szemes, Akos; Caruso, Damiano; Fuller, Stephen R; Bamberg, Fabian; Nikolaou, Konstantin; Schoepf, U Joseph

    2016-05-01

    To compare, on an intra-individual basis, the effect of automated tube voltage selection (ATVS), integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of aortic CTA studies using 2nd and 3rd generation dual-source CT (DSCT). We retrospectively evaluated 32 patients who had undergone CTA of the entire aorta with both 2nd generation DSCT at 120kV using filtered back projection (FBP) (protocol 1) and 3rd generation DSCT using ATVS, an integrated circuit detector and advanced iterative reconstruction (protocol 2). Contrast-to-noise ratio (CNR) was calculated. Image quality was subjectively evaluated using a five-point scale. Radiation dose parameters were recorded. All studies were considered of diagnostic image quality. CNR was significantly higher with protocol 2 (15.0±5.2 vs 11.0±4.2; p<.0001). Subjective image quality analysis revealed no significant differences for evaluation of attenuation (p=0.08501) but image noise was rated significantly lower with protocol 2 (p=0.0005). Mean tube voltage and effective dose were 94.7±14.1kV and 6.7±3.9mSv with protocol 2; 120±0kV and 11.5±5.2mSv with protocol 1 (p<0.0001, respectively). Aortic CTA performed with 3rd generation DSCT, ATVS, integrated circuit detector, and advanced iterative reconstruction allow a substantial reduction of radiation exposure while improving image quality in comparison to 120kV imaging with FBP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Assessment of quality of life of patients who underwent anterior cruciate ligament reconstruction and a rehabilitation program

    Directory of Open Access Journals (Sweden)

    Moises Cohen

    2004-12-01

    Full Text Available Introduction: Quality of life can be defined as the expression of aconceptual model that tries to represent patient’s perspectivesand his/her level of satisfaction expressed by numbers. Theobjective of this study is to evaluate the parameters of quality oflife of 23 patients who underwent surgery for anterior cruciateligament reconstruction. Methods: We adopted SF-36, a generichealth-related evaluation questionnaire, to obtain informationregarding several aspects of patients’ health conditions, and theLysholm questionnaire, specific to evaluate the symptoms andfunction of the knee. The questionnaires were applied at two stagesof the treatment: pre- and postoperatively (after the rehabilitationprogram. Results: Before surgery, the Lysholm questionnairepresented the following results: excellent in 4% of the cases, goodin 22%, fair in 22%, and poor in 52%. After surgery (Lysholm e SF-36 the correlation level was approximately 44% (p = 0.041.Discussion: The correlation between the Lysholm and the SF-36questionnaires showed the following: the lower the level of pain,the higher the Lysholm score. The high scores presented by theLysholm questionnaire are directly proportional to physical andemotional aspects, and to functional capacity. Conclusion:Analysis of both questionnaires, as well as of their correlation,showed some improvement in patients´ quality of life. We werealso able to demonstrate the importance and usefulness of applyingthe two questionnaires at three different moments: before, duringand after physiotherapeutic intervention.

  16. Comparison of virtual monoenergetic and polyenergetic images reconstructed from dual-layer detector CT angiography of the head and neck.

    Science.gov (United States)

    Neuhaus, Victor; Große Hokamp, Nils; Abdullayev, Nuran; Maus, Volker; Kabbasch, Christoph; Mpotsaris, Anastasios; Maintz, David; Borggrefe, Jan

    2018-03-01

    To compare the image quality of virtual monoenergetic images and polyenergetic images reconstructed from dual-layer detector CT angiography (DLCTA). Thirty patients who underwent DLCTA of the head and neck were retrospectively identified and polyenergetic as well as virtual monoenergetic images (40 to 120 keV) were reconstructed. Signals (± SD) of the cervical and cerebral vessels as well as lateral pterygoid muscle and the air surrounding the head were measured to calculate the CNR and SNR. In addition, subjective image quality was assessed using a 5-point Likert scale. Student's t-test and Wilcoxon test were used to determine statistical significance. Compared to polyenergetic images, although noise increased with lower keV, CNR (p 0.05) of the cervical, petrous and intracranial vessels were improved in virtual monoenergetic images at 40 keV and virtual monoenergetic images at 45 keV were also rated superior regarding vascular contrast, assessment of arteries close to the skull base and small arterial branches (p virtual monoenergetic images reconstructed from DLCTA at low keV ranging from 40 to 45 keV improve the objective and subjective image quality of extra- and intracranial vessels and facilitate assessment of vessels close to the skull base and of small arterial branches. • Virtual monoenergetic images greatly improve attenuation, while noise only slightly increases. • Virtual monoenergetic images show superior contrast-to-noise ratios compared to polyenergetic images. • Virtual monoenergetic images significantly improve image quality at low keV.

  17. Improved iterative image reconstruction algorithm for the exterior problem of computed tomography

    International Nuclear Information System (INIS)

    Guo, Yumeng; Zeng, Li

    2017-01-01

    In industrial applications that are limited by the angle of a fan-beam and the length of a detector, the exterior problem of computed tomography (CT) uses only the projection data that correspond to the external annulus of the objects to reconstruct an image. Because the reconstructions are not affected by the projection data that correspond to the interior of the objects, the exterior problem is widely applied to detect cracks in the outer wall of large-sized objects, such as in-service pipelines. However, image reconstruction in the exterior problem is still a challenging problem due to truncated projection data and beam-hardening, both of which can lead to distortions and artifacts. Thus, developing an effective algorithm and adopting a scanning trajectory suited for the exterior problem may be valuable. In this study, an improved iterative algorithm that combines total variation minimization (TVM) with a region scalable fitting (RSF) model was developed for a unilateral off-centered scanning trajectory and can be utilized to inspect large-sized objects for defects. Experiments involving simulated phantoms and real projection data were conducted to validate the practicality of our algorithm. Furthermore, comparative experiments show that our algorithm outperforms others in suppressing the artifacts caused by truncated projection data and beam-hardening.

  18. Improved iterative image reconstruction algorithm for the exterior problem of computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Yumeng [Chongqing University, College of Mathematics and Statistics, Chongqing 401331 (China); Chongqing University, ICT Research Center, Key Laboratory of Optoelectronic Technology and System of the Education Ministry of China, Chongqing 400044 (China); Zeng, Li, E-mail: drlizeng@cqu.edu.cn [Chongqing University, College of Mathematics and Statistics, Chongqing 401331 (China); Chongqing University, ICT Research Center, Key Laboratory of Optoelectronic Technology and System of the Education Ministry of China, Chongqing 400044 (China)

    2017-01-11

    In industrial applications that are limited by the angle of a fan-beam and the length of a detector, the exterior problem of computed tomography (CT) uses only the projection data that correspond to the external annulus of the objects to reconstruct an image. Because the reconstructions are not affected by the projection data that correspond to the interior of the objects, the exterior problem is widely applied to detect cracks in the outer wall of large-sized objects, such as in-service pipelines. However, image reconstruction in the exterior problem is still a challenging problem due to truncated projection data and beam-hardening, both of which can lead to distortions and artifacts. Thus, developing an effective algorithm and adopting a scanning trajectory suited for the exterior problem may be valuable. In this study, an improved iterative algorithm that combines total variation minimization (TVM) with a region scalable fitting (RSF) model was developed for a unilateral off-centered scanning trajectory and can be utilized to inspect large-sized objects for defects. Experiments involving simulated phantoms and real projection data were conducted to validate the practicality of our algorithm. Furthermore, comparative experiments show that our algorithm outperforms others in suppressing the artifacts caused by truncated projection data and beam-hardening.

  19. An improved reconstruction of May-June precipitation using tree-ring data from western Turkey and its links to volcanic eruptions.

    Science.gov (United States)

    Köse, Nesibe; Akkemik, Unal; Güner, H Tuncay; Dalfes, H Nüzhet; Grissino-Mayer, Henri D; Ozeren, M Sinan; Kındap, Tayfun

    2013-09-01

    We developed a high quality reconstruction of May-June precipitation for the interior region of southwestern Turkey using regional tree-ring data calibrated with meteorological data from Burdur. In this study, three new climate sensitive black pine chronologies were built. In addition to new chronologies, four previously published black pine chronologies were used for the reconstruction. Two separate reconstructions were developed. The first reconstruction used all site chronologies over the common interval AD 1813-2004. The second reconstruction used four of the chronologies with a common interval AD 1692-2004. R² values of the reconstructions were 0.64 and 0.51 with RE values of 0.63 and 0.51, respectively. During the period AD 1692-1938, 41 dry and 48 wet events were found. Very dry years occurred in AD 1725, 1814, 1851, 1887, 1916, and 1923, while very wet years occurred in AD 1736, 1780, 1788, 1803, and 1892. The longest dry period was 16 years long between 1860 and 1875. We then explored relationships between the reconstructed rainfall patterns and major volcanic eruptions, and discovered that wetter than normal years occurred during or immediately after the years with the largest volcanic eruptions.

  20. Improvement of posture stability by vibratory stimulation following anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Brunetti, O; Filippi, G M; Lorenzini, M; Liti, A; Panichi, R; Roscini, M; Pettorossi, V E; Cerulli, G

    2006-11-01

    Surgical reconstruction of the anterior cruciate ligament (ACL) may reduce, but it does not always eliminate, knee and body instability because of a persisting proprioceptive deficit. In order to enhance body stability, a new protocol of treatment has been proposed consisting of mechanical vibration (100 Hz frequency and < 20 microm amplitude) of the quadriceps muscle in the leg that has undergone ACL reconstruction. In our trials, stimulation was performed when the quadriceps muscle was kept isometrically contracted. Treatment was started one month after surgery. Vibration was applied for short periods over three consecutive days. Nine months after treatment, postural stability was re-evaluated with the subjects standing on one leg with open and with closed eyes. The postural stability of the subjects having undergone vibration treatment, standing on the operated leg was significantly improved one day after treatment when evaluated as mean of speed and elliptic area of the center of pressure. The improvement persisted and increased during the following weeks. Peak torques of the operated leg extensor muscles also increased and reached values close to that of the leg, which had not been operated. Conversely, the balance of the untreated subjects standing on the operated leg did not improve and the restoration of the extensor muscle peak torque was poor. It is concluded that short lasting proprioceptive activation by vibration may lead to a faster and more complete equilibrium recovery probably by permanently changing the network controlling knee posture.

  1. Abdominal wall reconstruction for large incisional hernia restores expiratory lung function

    DEFF Research Database (Denmark)

    Jensen, Kristian K; Backer, Vibeke; Jorgensen, Lars N

    2017-01-01

    BACKGROUND: Respiratory complications secondary to intermittent intra-abdominal hypertension and/or atelectasis are common after abdominal wall reconstruction for large incisional hernias. It is unknown if the respiratory function of this patient group is affected long term or impairs activities...... of daily living. We hypothesized that abdominal wall reconstruction for large incisional hernia would not lead to improved, long-term pulmonary function or respiratory quality of life. METHODS: Eighteen patients undergoing open abdominal wall reconstruction with mesh for a large incisional hernia...... (horizontal fascial defect width >10 cm) were compared with 18 patients with an intact abdominal wall who underwent colorectal resection. Patients were examined pre- and 1-year postoperatively. Examined measures included forced vital capacity, forced expiratory volume in first second, peak expiratory flow...

  2. Matrix completion-based reconstruction for undersampled magnetic resonance fingerprinting data.

    Science.gov (United States)

    Doneva, Mariya; Amthor, Thomas; Koken, Peter; Sommer, Karsten; Börnert, Peter

    2017-09-01

    An iterative reconstruction method for undersampled magnetic resonance fingerprinting data is presented. The method performs the reconstruction entirely in k-space and is related to low rank matrix completion methods. A low dimensional data subspace is estimated from a small number of k-space locations fully sampled in the temporal direction and used to reconstruct the missing k-space samples before MRF dictionary matching. Performing the iterations in k-space eliminates the need for applying a forward and an inverse Fourier transform in each iteration required in previously proposed iterative reconstruction methods for undersampled MRF data. A projection onto the low dimensional data subspace is performed as a matrix multiplication instead of a singular value thresholding typically used in low rank matrix completion, further reducing the computational complexity of the reconstruction. The method is theoretically described and validated in phantom and in-vivo experiments. The quality of the parameter maps can be significantly improved compared to direct matching on undersampled data. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. 42 CFR 441.474 - Quality assurance and improvement plan.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Quality assurance and improvement plan. 441.474... improvement plan. (a) The State must provide a quality assurance and improvement plan that describes the State... pursue opportunities for system improvement. (b) The quality assurance and improvement plan shall also...

  4. Methodology of quality improvement projects for the Texas Medicare population.

    Science.gov (United States)

    Pendergrass, P W; Abel, R L; Bing, M; Vaughn, R; McCauley, C

    1998-07-01

    The Texas Medical Foundation, the quality improvement organization for the state of Texas, develops local quality improvement projects for the Medicare population. These projects are developed as part of the Health Care Quality Improvement Program undertaken by the Health Care Financing Administration. The goal of a local quality improvement project is to collaborate with providers to identify and reduce the incidence of unintentional variations in the delivery of care that negatively impact outcomes. Two factors are critical to the success of a quality improvement project. First, as opposed to peer review that is based on implicit criteria, quality improvement must be based on explicit criteria. These criteria represent key steps in the delivery of care that have been shown to improve outcomes for a specific disease. Second, quality improvement must be performed in partnership with the health care community. As such, the health care community must play an integral role in the design and evaluation of a quality improvement project and in the design and implementation of the resulting quality improvement plan. Specifically, this article provides a historical perspective for the transition from peer review to quality improvement. It discusses key steps used in developing and implementing local quality improvement projects including topic selection, quality indicator development, collaborator recruitment, and measurement of performance/improvement. Two Texas Medical Foundation projects are described to highlight the current methodology and to illustrate the impact of quality improvement projects.

  5. Characterization of a computed tomography iterative reconstruction algorithm by image quality evaluations with an anthropomorphic phantom

    International Nuclear Information System (INIS)

    Rampado, O.; Bossi, L.; Garabello, D.; Davini, O.; Ropolo, R.

    2012-01-01

    Objective: This study aims to investigate the consequences on dose and image quality of the choices of different combinations of NI and adaptive statistical iterative reconstruction (ASIR) percentage, the image quality parameters of GE CT equipment. Methods: An anthropomorphic phantom was used to simulate the chest and upper abdomen of a standard weight patient. Images were acquired with tube current modulation and different values of noise index, in the range 10–22 for a slice thickness of 5 mm and a tube voltage of 120 kV. For each selected noise index, several image series were reconstructed using different percentages of ASIR (0, 40, 50, 60, 70, 100). Quantitative noise was assessed at different phantom locations. Computed tomography dose index (CTDI) and dose length products (DLP) were recorded. Three radiologists reviewed the images in a blinded and randomized manner and assessed the subjective image quality by comparing the image series with the one acquired with the reference protocol (noise index 14, ASIR 40%). The perceived noise, contrast, edge sharpness and overall quality were graded on a scale from −2 (much worse) to +2 (much better). Results: A repeatable trend of noise reduction versus the percentage of ASIR was observed for different noise levels and phantom locations. The different combinations of noise index and percentage of ASIR to obtain a desired dose reduction were assessed. The subjective image quality evaluation evidenced a possible dose reduction between 24 and 40% as a consequence of an increment of ASIR percentage to 50 or 70%, respectively. Conclusion: These results highlighted that the same patient dose reduction can be obtained with several combinations of noise index and percentages of ASIR, providing a model with which to choose these acquisition parameters in future optimization studies, with the aim of reducing patient dose by maintaining image quality in diagnostic levels.

  6. Characterization of a computed tomography iterative reconstruction algorithm by image quality evaluations with an anthropomorphic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Rampado, O., E-mail: orampado@molinette.piemonte.it [S.C. Fisica Sanitaria, San Giovanni Battista Hospital of Turin, Corso Bramante 88, Torino 10126 (Italy); Bossi, L., E-mail: laura-bossi@hotmail.it [S.C. Fisica Sanitaria, San Giovanni Battista Hospital of Turin, Corso Bramante 88, Torino 10126 (Italy); Garabello, D., E-mail: dgarabello@molinette.piemonte.it [S.C. Radiodiagnostica DEA, San Giovanni Battista Hospital of Turin, Corso Bramante 88, Torino 10126 (Italy); Davini, O., E-mail: odavini@molinette.piemonte.it [S.C. Radiodiagnostica DEA, San Giovanni Battista Hospital of Turin, Corso Bramante 88, Torino 10126 (Italy); Ropolo, R., E-mail: rropolo@molinette.piemonte.it [S.C. Fisica Sanitaria, San Giovanni Battista Hospital of Turin, Corso Bramante 88, Torino 10126 (Italy)

    2012-11-15

    Objective: This study aims to investigate the consequences on dose and image quality of the choices of different combinations of NI and adaptive statistical iterative reconstruction (ASIR) percentage, the image quality parameters of GE CT equipment. Methods: An anthropomorphic phantom was used to simulate the chest and upper abdomen of a standard weight patient. Images were acquired with tube current modulation and different values of noise index, in the range 10-22 for a slice thickness of 5 mm and a tube voltage of 120 kV. For each selected noise index, several image series were reconstructed using different percentages of ASIR (0, 40, 50, 60, 70, 100). Quantitative noise was assessed at different phantom locations. Computed tomography dose index (CTDI) and dose length products (DLP) were recorded. Three radiologists reviewed the images in a blinded and randomized manner and assessed the subjective image quality by comparing the image series with the one acquired with the reference protocol (noise index 14, ASIR 40%). The perceived noise, contrast, edge sharpness and overall quality were graded on a scale from -2 (much worse) to +2 (much better). Results: A repeatable trend of noise reduction versus the percentage of ASIR was observed for different noise levels and phantom locations. The different combinations of noise index and percentage of ASIR to obtain a desired dose reduction were assessed. The subjective image quality evaluation evidenced a possible dose reduction between 24 and 40% as a consequence of an increment of ASIR percentage to 50 or 70%, respectively. Conclusion: These results highlighted that the same patient dose reduction can be obtained with several combinations of noise index and percentages of ASIR, providing a model with which to choose these acquisition parameters in future optimization studies, with the aim of reducing patient dose by maintaining image quality in diagnostic levels.

  7. Sparsity-promoting orthogonal dictionary updating for image reconstruction from highly undersampled magnetic resonance data

    International Nuclear Information System (INIS)

    Huang, Jinhong; Guo, Li; Feng, Qianjin; Chen, Wufan; Feng, Yanqiu

    2015-01-01

    Image reconstruction from undersampled k-space data accelerates magnetic resonance imaging (MRI) by exploiting image sparseness in certain transform domains. Employing image patch representation over a learned dictionary has the advantage of being adaptive to local image structures and thus can better sparsify images than using fixed transforms (e.g. wavelets and total variations). Dictionary learning methods have recently been introduced to MRI reconstruction, and these methods demonstrate significantly reduced reconstruction errors compared to sparse MRI reconstruction using fixed transforms. However, the synthesis sparse coding problem in dictionary learning is NP-hard and computationally expensive. In this paper, we present a novel sparsity-promoting orthogonal dictionary updating method for efficient image reconstruction from highly undersampled MRI data. The orthogonality imposed on the learned dictionary enables the minimization problem in the reconstruction to be solved by an efficient optimization algorithm which alternately updates representation coefficients, orthogonal dictionary, and missing k-space data. Moreover, both sparsity level and sparse representation contribution using updated dictionaries gradually increase during iterations to recover more details, assuming the progressively improved quality of the dictionary. Simulation and real data experimental results both demonstrate that the proposed method is approximately 10 to 100 times faster than the K-SVD-based dictionary learning MRI method and simultaneously improves reconstruction accuracy. (paper)

  8. Sparsity-promoting orthogonal dictionary updating for image reconstruction from highly undersampled magnetic resonance data.

    Science.gov (United States)

    Huang, Jinhong; Guo, Li; Feng, Qianjin; Chen, Wufan; Feng, Yanqiu

    2015-07-21

    Image reconstruction from undersampled k-space data accelerates magnetic resonance imaging (MRI) by exploiting image sparseness in certain transform domains. Employing image patch representation over a learned dictionary has the advantage of being adaptive to local image structures and thus can better sparsify images than using fixed transforms (e.g. wavelets and total variations). Dictionary learning methods have recently been introduced to MRI reconstruction, and these methods demonstrate significantly reduced reconstruction errors compared to sparse MRI reconstruction using fixed transforms. However, the synthesis sparse coding problem in dictionary learning is NP-hard and computationally expensive. In this paper, we present a novel sparsity-promoting orthogonal dictionary updating method for efficient image reconstruction from highly undersampled MRI data. The orthogonality imposed on the learned dictionary enables the minimization problem in the reconstruction to be solved by an efficient optimization algorithm which alternately updates representation coefficients, orthogonal dictionary, and missing k-space data. Moreover, both sparsity level and sparse representation contribution using updated dictionaries gradually increase during iterations to recover more details, assuming the progressively improved quality of the dictionary. Simulation and real data experimental results both demonstrate that the proposed method is approximately 10 to 100 times faster than the K-SVD-based dictionary learning MRI method and simultaneously improves reconstruction accuracy.

  9. Assessing the impact of continuous quality improvement/total quality management: concept versus implementation.

    Science.gov (United States)

    Shortell, S M; O'Brien, J L; Carman, J M; Foster, R W; Hughes, E F; Boerstler, H; O'Connor, E J

    1995-01-01

    OBJECTIVE: This study examines the relationships among organizational culture, quality improvement processes and selected outcomes for a sample of up to 61 U. S. hospitals. DATA SOURCES AND STUDY SETTING: Primary data were collected from 61 U. S. hospitals (located primarily in the midwest and the west) on measures related to continuous quality improvement/total quality management (CQI/TQM), organizational culture, implementation approaches, and degree of quality improvement implementation based on the Baldrige Award criteria. These data were combined with independently collected data on perceived impact and objective measures of clinical efficiency (i.e., charges and length of stay) for six clinical conditions. STUDY DESIGN: The study involved cross-sectional examination of the named relationships. DATA COLLECTION/EXTRACTION METHODS: Reliable and valid scales for the organizational culture and quality improvement implementation measures were developed based on responses from over 7,000 individuals across the 61 hospitals with an overall completion rate of 72 percent. Independent data on perceived impact were collected from a national survey and independent data on clinical efficiency from a companion study of managed care. PRINCIPAL FINDINGS: A participative, flexible, risk-taking organizational culture was significantly related to quality improvement implementation. Quality improvement implementation, in turn, was positively associated with greater perceived patient outcomes and human resource development. Larger-size hospitals experienced lower clinical efficiency with regard to higher charges and higher length of stay, due in part to having more bureaucratic and hierarchical cultures that serve as a barrier to quality improvement implementation. CONCLUSIONS: What really matters is whether or not a hospital has a culture that supports quality improvement work and an approach that encourages flexible implementation. Larger-size hospitals face more difficult

  10. Penalised Maximum Likelihood Simultaneous Longitudinal PET Image Reconstruction with Difference-Image Priors.

    Science.gov (United States)

    Ellis, Sam; Reader, Andrew J

    2018-04-26

    reconstructions with increased counts levels. In tumour regions each method produces subtly different results in terms of preservation of tumour quantification and reconstruction root mean-squared error (RMSE). In particular, in the two-scan simulations, the DE-PML method produced tumour means in close agreement with MLEM reconstructions, while the DTV-PML method produced the lowest errors due to noise reduction within the tumour. Across a range of tumour responses and different numbers of scans, similar results were observed, with DTV-PML producing the lowest errors of the three priors and DE-PML producing the lowest bias. Similar improvements were observed in the reconstructions of the real longitudinal datasets, although imperfect alignment of the two PET images resulted in additional changes in the difference image that affected the performance of the proposed methods. Reconstruction of longitudinal datasets by penalising difference images between pairs of scans from a data series allows for noise reduction in all reconstructed images. An appropriate choice of penalty term and penalty strength allows for this noise reduction to be achieved while maintaining reconstruction performance in regions of change, either in terms of quantification of mean intensity via DE-PML, or in terms of tumour RMSE via DTV-PML. Overall, improving the image quality of longitudinal datasets via simultaneous reconstruction has the potential to improve upon currently used methods, allow dose reduction, or reduce scan time while maintaining image quality at current levels. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations

    International Nuclear Information System (INIS)

    Guzinski, Maciej; Waszczuk, Lukasz; Sasiadek, Marek J.

    2016-01-01

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. (orig.)

  12. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations

    Energy Technology Data Exchange (ETDEWEB)

    Guzinski, Maciej; Waszczuk, Lukasz; Sasiadek, Marek J. [Wroclaw Medical University, Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw (Poland)

    2016-10-15

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. (orig.)

  13. Can Quality Improvement System Improve Childcare Site Performance in School Readiness?

    Science.gov (United States)

    Ma, Xin; Shen, Jianping; Lu, Xuejin; Brandi, Karen; Goodman, Jeff; Watson, Grace

    2013-01-01

    The authors evaluated the effectiveness of the Quality Improvement System (QIS) developed and implemented by Children's Services Council of Palm Beach County (Florida) as a voluntary initiative to improve the quality of childcare and education. They adopted a growth model approach to investigate whether childcare sites that participated in QIS…

  14. Optimized image acquisition for breast tomosynthesis in projection and reconstruction space

    International Nuclear Information System (INIS)

    Chawla, Amarpreet S.; Lo, Joseph Y.; Baker, Jay A.; Samei, Ehsan

    2009-01-01

    Breast tomosynthesis has been an exciting new development in the field of breast imaging. While the diagnostic improvement via tomosynthesis is notable, the full potential of tomosynthesis has not yet been realized. This may be attributed to the dependency of the diagnostic quality of tomosynthesis on multiple variables, each of which needs to be optimized. Those include dose, number of angular projections, and the total angular span of those projections. In this study, the authors investigated the effects of these acquisition parameters on the overall diagnostic image quality of breast tomosynthesis in both the projection and reconstruction space. Five mastectomy specimens were imaged using a prototype tomosynthesis system. 25 angular projections of each specimen were acquired at 6.2 times typical single-view clinical dose level. Images at lower dose levels were then simulated using a noise modification routine. Each projection image was supplemented with 84 simulated 3 mm 3D lesions embedded at the center of 84 nonoverlapping ROIs. The projection images were then reconstructed using a filtered backprojection algorithm at different combinations of acquisition parameters to investigate which of the many possible combinations maximizes the performance. Performance was evaluated in terms of a Laguerre-Gauss channelized Hotelling observer model-based measure of lesion detectability. The analysis was also performed without reconstruction by combining the model results from projection images using Bayesian decision fusion algorithm. The effect of acquisition parameters on projection images and reconstructed slices were then compared to derive an optimization rule for tomosynthesis. The results indicated that projection images yield comparable but higher performance than reconstructed images. Both modes, however, offered similar trends: Performance improved with an increase in the total acquisition dose level and the angular span. Using a constant dose level and angular

  15. Improving Indoor Air Quality

    Science.gov (United States)

    Usually the most effective way to improve indoor air quality is to eliminate individual sources of pollution or to reduce their emissions. Some sources, like those that contain asbestos, can be sealed or enclosed.

  16. Stochastic Optical Reconstruction Microscopy (STORM).

    Science.gov (United States)

    Xu, Jianquan; Ma, Hongqiang; Liu, Yang

    2017-07-05

    Super-resolution (SR) fluorescence microscopy, a class of optical microscopy techniques at a spatial resolution below the diffraction limit, has revolutionized the way we study biology, as recognized by the Nobel Prize in Chemistry in 2014. Stochastic optical reconstruction microscopy (STORM), a widely used SR technique, is based on the principle of single molecule localization. STORM routinely achieves a spatial resolution of 20 to 30 nm, a ten-fold improvement compared to conventional optical microscopy. Among all SR techniques, STORM offers a high spatial resolution with simple optical instrumentation and standard organic fluorescent dyes, but it is also prone to image artifacts and degraded image resolution due to improper sample preparation or imaging conditions. It requires careful optimization of all three aspects-sample preparation, image acquisition, and image reconstruction-to ensure a high-quality STORM image, which will be extensively discussed in this unit. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  17. Improving PSA quality of KSNP PSA model

    International Nuclear Information System (INIS)

    Yang, Joon Eon; Ha, Jae Joo

    2004-01-01

    In the RIR (Risk-informed Regulation), PSA (Probabilistic Safety Assessment) plays a major role because it provides overall risk insights for the regulatory body and utility. Therefore, the scope, the level of details and the technical adequacy of PSA, i.e. the quality of PSA is to be ensured for the successful RIR. To improve the quality of Korean PSA, we evaluate the quality of the KSNP (Korean Standard Nuclear Power Plant) internal full-power PSA model based on the 'ASME PRA Standard' and the 'NEI PRA Peer Review Process Guidance.' As a working group, PSA experts of the regulatory body and industry also participated in the evaluation process. It is finally judged that the overall quality of the KSNP PSA is between the ASME Standard Capability Category I and II. We also derive some items to be improved for upgrading the quality of the PSA up to the ASME Standard Capability Category II. In this paper, we show the result of quality evaluation, and the activities to improve the quality of the KSNP PSA model

  18. Modalities of hemodialysis: Quality improvement

    Directory of Open Access Journals (Sweden)

    Ayman Karkar

    2012-01-01

    Full Text Available Hemodialysis (HD treatment had, over many years, improved the survival rate of patients with end-stage renal disease. However, standard or conventional HD prescription is far from being optimal in replacing the function of normal kidneys. Its unphysiologic clearance pattern and inability to remove all types and sizes of uremic toxins results in inter- and intra-dialysis complications and an unacceptably high rate of cardiovascular morbidity and mortality. Efficiency of HD can be improved by increasing blood and dialysate flow rates, dialyzer size and surface area and duration and frequency of dialysis sessions. Home HD, where short daily or long slow nocturnal HD sessions can conveniently be performed, provides an excellent option for quality of life improvement and reduction in morbidity and mortality. Recent innovations in the specifications of HD machines and improvement in dialysis membranes characteristics and water treatment technology paved the way for achieving quality HD. These advancements have resulted in efficient implementation of adsorption, diffusion and/or convection principles using adsorption HD, hemofiltration, hemodiafiltration (HDF and online HDF modalities in order to achieve optimum HD. Implementation of these innovations resulted in better quality care achievements in clinical practice and reduction in morbidity and mortality rates among HD patients.

  19. A quality improvement management model for renal care.

    Science.gov (United States)

    Vlchek, D L; Day, L M

    1991-04-01

    The purpose of this article is to explore the potential for applying the theory and tools of quality improvement (total quality management) in the renal care setting. We believe that the coupling of the statistical techniques used in the Deming method of quality improvement, with modern approaches to outcome and process analysis, will provide the renal care community with powerful tools, not only for improved quality (i.e., reduced morbidity and mortality), but also for technology evaluation and resource allocation.

  20. A deep learning-based reconstruction of cosmic ray-induced air showers

    Science.gov (United States)

    Erdmann, M.; Glombitza, J.; Walz, D.

    2018-01-01

    We describe a method of reconstructing air showers induced by cosmic rays using deep learning techniques. We simulate an observatory consisting of ground-based particle detectors with fixed locations on a regular grid. The detector's responses to traversing shower particles are signal amplitudes as a function of time, which provide information on transverse and longitudinal shower properties. In order to take advantage of convolutional network techniques specialized in local pattern recognition, we convert all information to the image-like grid of the detectors. In this way, multiple features, such as arrival times of the first particles and optimized characterizations of time traces, are processed by the network. The reconstruction quality of the cosmic ray arrival direction turns out to be competitive with an analytic reconstruction algorithm. The reconstructed shower direction, energy and shower depth show the expected improvement in resolution for higher cosmic ray energy.

  1. Improvement image in tomosynthesis

    International Nuclear Information System (INIS)

    Gomi, Tsutomu; Umeda, Tokuo; Takeda, Tohoru; Saito, Kyouko; Sakaguchi, Kazuya; Nakajima, Masahiro; Koshida, Kichirou

    2012-01-01

    We evaluated the X-ray digital tomosynthesis (DT) reconstruction processing method for metal artifact reduction and the application of wavelet denoising to selectively remove quantum noise and suggest the possibility of image quality improvement using a novel application for chest. In orthopedic DT imaging, we developed artifact reduction methods based on a modified Shepp and Logan reconstruction filter kernel realized by taking into account additional weighing by direct current (DC) components in frequency domain space. Processing leads to an increase in the ratio of low-frequency components in an image. The effectiveness of the method in enhancing the visibility of a prosthetic case was quantified in terms of removal of ghosting artifacts. In chest DT imaging, the technique was implemented on a DT system and experimentally evaluated through chest phantom measurements, spatial resolution and compared with an existing post-reconstruction wavelet denoise algorithm by Badea et al. Our wavelet technique with balance sparsity-norm contrast-to-noise ratio (CNR) effectively decreased quantum noise in the reconstructed images with and improvement when applied to pre-reconstruction image for post-reconstruction. The results of our technique showed that although modulation transfer function (MTF) did not vary (preserving spatial resolution), the existing wavelet denoise algorithm caused MTF deterioration. (author)

  2. Improved 3D reconstruction in smart-room environments using ToF imaging

    DEFF Research Database (Denmark)

    Guðmundsson, Sigurjón Árni; Pardas, Montse; Casas, Josep R.

    2010-01-01

    This paper presents the use of Time-of-Flight (ToF) cameras in smart-rooms and how this leads to improved results in segmenting the people in the room from the background and consequently better 3D reconstruction of foreground objects. A calibrated rig consisting of one Swissranger SR3100 Time-of...... of eliminating regional artifacts and therefore creating a more robust input for higher level applications such as people tracking or human motion analysis....

  3. Methods of X-ray CT image reconstruction from few projections

    International Nuclear Information System (INIS)

    Wang, H.

    2011-01-01

    To improve the safety (low dose) and the productivity (fast acquisition) of a X-ray CT system, we want to reconstruct a high quality image from a small number of projections. The classical reconstruction algorithms generally fail since the reconstruction procedure is unstable and suffers from artifacts. A new approach based on the recently developed 'Compressed Sensing' (CS) theory assumes that the unknown image is in some sense 'sparse' or 'compressible', and the reconstruction is formulated through a non linear optimization problem (TV/l1 minimization) by enhancing the sparsity. Using the pixel (or voxel in 3D) as basis, to apply the CS framework in CT one usually needs a 'sparsifying' transform, and combines it with the 'X-ray projector' which applies on the pixel image. In this thesis, we have adapted a 'CT-friendly' radial basis of Gaussian family called 'blob' to the CS-CT framework. The blob has better space-frequency localization properties than the pixel, and many operations, such as the X-ray transform, can be evaluated analytically and are highly parallelizable (on GPU platform). Compared to the classical Kaisser-Bessel blob, the new basis has a multi-scale structure: an image is the sum of dilated and translated radial Mexican hat functions. The typical medical objects are compressible under this basis, so the sparse representation system used in the ordinary CS algorithms is no more needed. 2D simulations show that the existing TV and l1 algorithms are more efficient and the reconstructions have better visual quality than the equivalent approach based on the pixel or wavelet basis. The new approach has also been validated on 2D experimental data, where we have observed that in general the number of projections can be reduced to about 50%, without compromising the image quality. (author) [fr

  4. 45 CFR 1304.60 - Deficiencies and quality improvement plans.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Deficiencies and quality improvement plans. 1304... must correct the deficiency either immediately or pursuant to a Quality Improvement Plan. (c) An Early... Improvement Plan must submit to the responsible HHS official a Quality Improvement Plan specifying, for each...

  5. Robust sliding-window reconstruction for Accelerating the acquisition of MR fingerprinting.

    Science.gov (United States)

    Cao, Xiaozhi; Liao, Congyu; Wang, Zhixing; Chen, Ying; Ye, Huihui; He, Hongjian; Zhong, Jianhui

    2017-10-01

    To develop a method for accelerated and robust MR fingerprinting (MRF) with improved image reconstruction and parameter matching processes. A sliding-window (SW) strategy was applied to MRF, in which signal and dictionary matching was conducted between fingerprints consisting of mixed-contrast image series reconstructed from consecutive data frames segmented by a sliding window, and a precalculated mixed-contrast dictionary. The effectiveness and performance of this new method, dubbed SW-MRF, was evaluated in both phantom and in vivo. Error quantifications were conducted on results obtained with various settings of SW reconstruction parameters. Compared with the original MRF strategy, the results of both phantom and in vivo experiments demonstrate that the proposed SW-MRF strategy either provided similar accuracy with reduced acquisition time, or improved accuracy with equal acquisition time. Parametric maps of T 1 , T 2 , and proton density of comparable quality could be achieved with a two-fold or more reduction in acquisition time. The effect of sliding-window width on dictionary sensitivity was also estimated. The novel SW-MRF recovers high quality image frames from highly undersampled MRF data, which enables more robust dictionary matching with reduced numbers of data frames. This time efficiency may facilitate MRF applications in time-critical clinical settings. Magn Reson Med 78:1579-1588, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. PIRPLE: a penalized-likelihood framework for incorporation of prior images in CT reconstruction

    International Nuclear Information System (INIS)

    Stayman, J Webster; Dang, Hao; Ding, Yifu; Siewerdsen, Jeffrey H

    2013-01-01

    Over the course of diagnosis and treatment, it is common for a number of imaging studies to be acquired. Such imaging sequences can provide substantial patient-specific prior knowledge about the anatomy that can be incorporated into a prior-image-based tomographic reconstruction for improved image quality and better dose utilization. We present a general methodology using a model-based reconstruction approach including formulations of the measurement noise that also integrates prior images. This penalized-likelihood technique adopts a sparsity enforcing penalty that incorporates prior information yet allows for change between the current reconstruction and the prior image. Moreover, since prior images are generally not registered with the current image volume, we present a modified model-based approach that seeks a joint registration of the prior image in addition to the reconstruction of projection data. We demonstrate that the combined prior-image- and model-based technique outperforms methods that ignore the prior data or lack a noise model. Moreover, we demonstrate the importance of registration for prior-image-based reconstruction methods and show that the prior-image-registered penalized-likelihood estimation (PIRPLE) approach can maintain a high level of image quality in the presence of noisy and undersampled projection data. (paper)

  7. Computed Tomography Image Quality Evaluation of a New Iterative Reconstruction Algorithm in the Abdomen (Adaptive Statistical Iterative Reconstruction-V) a Comparison With Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection Reconstructions.

    Science.gov (United States)

    Goodenberger, Martin H; Wagner-Bartak, Nicolaus A; Gupta, Shiva; Liu, Xinming; Yap, Ramon Q; Sun, Jia; Tamm, Eric P; Jensen, Corey T

    The purpose of this study was to compare abdominopelvic computed tomography images reconstructed with adaptive statistical iterative reconstruction-V (ASIR-V) with model-based iterative reconstruction (Veo 3.0), ASIR, and filtered back projection (FBP). Abdominopelvic computed tomography scans for 36 patients (26 males and 10 females) were reconstructed using FBP, ASIR (80%), Veo 3.0, and ASIR-V (30%, 60%, 90%). Mean ± SD patient age was 32 ± 10 years with mean ± SD body mass index of 26.9 ± 4.4 kg/m. Images were reviewed by 2 independent readers in a blinded, randomized fashion. Hounsfield unit, noise, and contrast-to-noise ratio (CNR) values were calculated for each reconstruction algorithm for further comparison. Phantom evaluation of low-contrast detectability (LCD) and high-contrast resolution was performed. Adaptive statistical iterative reconstruction-V 30%, ASIR-V 60%, and ASIR 80% were generally superior qualitatively compared with ASIR-V 90%, Veo 3.0, and FBP (P ASIR-V 60% with respective CNR values of 5.54 ± 2.39, 8.78 ± 3.15, and 3.49 ± 1.77 (P ASIR 80% had the best and worst spatial resolution, respectively. Adaptive statistical iterative reconstruction-V 30% and ASIR-V 60% provided the best combination of qualitative and quantitative performance. Adaptive statistical iterative reconstruction 80% was equivalent qualitatively, but demonstrated inferior spatial resolution and LCD.

  8. Improving patient safety through quality assurance.

    Science.gov (United States)

    Raab, Stephen S

    2006-05-01

    Anatomic pathology laboratories use several quality assurance tools to detect errors and to improve patient safety. To review some of the anatomic pathology laboratory patient safety quality assurance practices. Different standards and measures in anatomic pathology quality assurance and patient safety were reviewed. Frequency of anatomic pathology laboratory error, variability in the use of specific quality assurance practices, and use of data for error reduction initiatives. Anatomic pathology error frequencies vary according to the detection method used. Based on secondary review, a College of American Pathologists Q-Probes study showed that the mean laboratory error frequency was 6.7%. A College of American Pathologists Q-Tracks study measuring frozen section discrepancy found that laboratories improved the longer they monitored and shared data. There is a lack of standardization across laboratories even for governmentally mandated quality assurance practices, such as cytologic-histologic correlation. The National Institutes of Health funded a consortium of laboratories to benchmark laboratory error frequencies, perform root cause analysis, and design error reduction initiatives, using quality assurance data. Based on the cytologic-histologic correlation process, these laboratories found an aggregate nongynecologic error frequency of 10.8%. Based on gynecologic error data, the laboratory at my institution used Toyota production system processes to lower gynecologic error frequencies and to improve Papanicolaou test metrics. Laboratory quality assurance practices have been used to track error rates, and laboratories are starting to use these data for error reduction initiatives.

  9. Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography.

    Science.gov (United States)

    May, Matthias S; Wüst, Wolfgang; Brand, Michael; Stahl, Christian; Allmendinger, Thomas; Schmidt, Bernhard; Uder, Michael; Lell, Michael M

    2011-07-01

    We sought to evaluate the image quality of iterative reconstruction in image space (IRIS) in half-dose (HD) datasets compared with full-dose (FD) and HD filtered back projection (FBP) reconstruction in abdominal computed tomography (CT). To acquire data with FD and HD simultaneously, contrast-enhanced abdominal CT was performed with a dual-source CT system, both tubes operating at 120 kV, 100 ref.mAs, and pitch 0.8. Three different image datasets were reconstructed from the raw data: Standard FD images applying FBP which served as reference, HD images applying FBP and HD images applying IRIS. For the HD data sets, only data from 1 tube detector-system was used. Quantitative image quality analysis was performed by measuring image noise in tissue and air. Qualitative image quality was evaluated according to the European Guidelines on Quality criteria for CT. Additional assessment of artifacts, lesion conspicuity, and edge sharpness was performed. : Image noise in soft tissue was substantially decreased in HD-IRIS (-3.4 HU, -22%) and increased in HD-FBP (+6.2 HU, +39%) images when compared with the reference (mean noise, 15.9 HU). No significant differences between the FD-FBP and HD-IRIS images were found for the visually sharp anatomic reproduction, overall diagnostic acceptability (P = 0.923), lesion conspicuity (P = 0.592), and edge sharpness (P = 0.589), while HD-FBP was rated inferior. Streak artifacts and beam hardening was significantly more prominent in HD-FBP while HD-IRIS images exhibited a slightly different noise pattern. Direct intrapatient comparison of standard FD body protocols and HD-IRIS reconstruction suggest that the latest iterative reconstruction algorithms allow for approximately 50% dose reduction without deterioration of the high image quality necessary for confident diagnosis.

  10. Instrument Variables for Reducing Noise in Parallel MRI Reconstruction

    Directory of Open Access Journals (Sweden)

    Yuchou Chang

    2017-01-01

    Full Text Available Generalized autocalibrating partially parallel acquisition (GRAPPA has been a widely used parallel MRI technique. However, noise deteriorates the reconstructed image when reduction factor increases or even at low reduction factor for some noisy datasets. Noise, initially generated from scanner, propagates noise-related errors during fitting and interpolation procedures of GRAPPA to distort the final reconstructed image quality. The basic idea we proposed to improve GRAPPA is to remove noise from a system identification perspective. In this paper, we first analyze the GRAPPA noise problem from a noisy input-output system perspective; then, a new framework based on errors-in-variables (EIV model is developed for analyzing noise generation mechanism in GRAPPA and designing a concrete method—instrument variables (IV GRAPPA to remove noise. The proposed EIV framework provides possibilities that noiseless GRAPPA reconstruction could be achieved by existing methods that solve EIV problem other than IV method. Experimental results show that the proposed reconstruction algorithm can better remove the noise compared to the conventional GRAPPA, as validated with both of phantom and in vivo brain data.

  11. Microvascular Radial Forearm Fasciocutaneous Free Flap for Palatomaxillary Reconstruction Following Malignant Tumor Resection

    International Nuclear Information System (INIS)

    ELSHERBINY, M.; MEBED, A.; MEBED, H.

    2008-01-01

    The aim of this study is to report on the patient's quality of life and outcomes after reconstruction of palatomaxillary defects by microvascular radial forearm fasciocutaneous free flap (RFFF) and dental obturator. Material and Methods: During the period between 2005-2007, 10 patients who had palato maxillary defects were immediately reconstructed using RFFF to restore physiologic oronasal separation. All patients were treated for malignant tumors of hard palate or maxilla and all had preservation of orbital floor. Vascular anastomoses were done with the facial vessels in the neck. All the patients underwent a lateral thigh split-thickness skin graft for closure of the donor site. Outcome measurements included post-operative assessment of flap survival and healing, speech, swallowing and diet evaluation and quality of life. Dental rehabilitation was done 3 months postoperatively for all patients. Results: Flap survival was successful in all cases. In the first 2 weeks post operatively, 80% of patients had very good swallowing, speech and diet ability in the form of soft chewable foods and by the end of 6 months, all patients had very good swallowing and speech function and were able to eat all types of foods. Dental rehabilitation with obturator was easily applied and the presence of the flap did not interfere with its application. The technique improved chewing ability and cosmosis. Complications included, small oronasal fistula in 2 patients (20%) who required secondary sutures and delayed wound healing of donor site in one patient. Conclusion: RFFF for soft tissue reconstruction after maxillectomy is a reliable technique that provides a definitive physiologic separation between oral and nasal cavity. This allows very early improvement of speech and swallowing without being totally dependent on obturator. Dental rehabilitation to improve chewing and cosmoses can be done easily with minimal home care. Subsequently, the quality of life is markedly improved

  12. A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging.

    Science.gov (United States)

    Yan, Hao; Zhen, Xin; Folkerts, Michael; Li, Yongbao; Pan, Tinsu; Cervino, Laura; Jiang, Steve B; Jia, Xun

    2014-07-01

    4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is invented to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3-0.5 mm for patients 1-3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1-1.5 min per phase. High-quality 4D-CBCT imaging based

  13. A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Hao; Folkerts, Michael; Jiang, Steve B., E-mail: xun.jia@utsouthwestern.edu, E-mail: steve.jiang@UTSouthwestern.edu; Jia, Xun, E-mail: xun.jia@utsouthwestern.edu, E-mail: steve.jiang@UTSouthwestern.edu [Department of Radiation Oncology, The University of Texas, Southwestern Medical Center, Dallas, Texas 75390 (United States); Zhen, Xin [Department of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515 (China); Li, Yongbao [Department of Radiation Oncology, The University of Texas, Southwestern Medical Center, Dallas, Texas 75390 and Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Pan, Tinsu [Department of Imaging Physics, The University of Texas, MD Anderson Cancer Center, Houston, Texas 77030 (United States); Cervino, Laura [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California 92093 (United States)

    2014-07-15

    Purpose: 4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. Methods: The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is invented to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. Results: The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3–0.5 mm for patients 1–3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1–1.5 min per phase

  14. Fast MR image reconstruction for partially parallel imaging with arbitrary k-space trajectories.

    Science.gov (United States)

    Ye, Xiaojing; Chen, Yunmei; Lin, Wei; Huang, Feng

    2011-03-01

    Both acquisition and reconstruction speed are crucial for magnetic resonance (MR) imaging in clinical applications. In this paper, we present a fast reconstruction algorithm for SENSE in partially parallel MR imaging with arbitrary k-space trajectories. The proposed method is a combination of variable splitting, the classical penalty technique and the optimal gradient method. Variable splitting and the penalty technique reformulate the SENSE model with sparsity regularization as an unconstrained minimization problem, which can be solved by alternating two simple minimizations: One is the total variation and wavelet based denoising that can be quickly solved by several recent numerical methods, whereas the other one involves a linear inversion which is solved by the optimal first order gradient method in our algorithm to significantly improve the performance. Comparisons with several recent parallel imaging algorithms indicate that the proposed method significantly improves the computation efficiency and achieves state-of-the-art reconstruction quality.

  15. Improving organizational climate for quality and quality of care: does membership in a collaborative help?

    Science.gov (United States)

    Nembhard, Ingrid M; Northrup, Veronika; Shaller, Dale; Cleary, Paul D

    2012-11-01

    The lack of quality-oriented organizational climates is partly responsible for deficiencies in patient-centered care and poor quality more broadly. To improve their quality-oriented climates, several organizations have joined quality improvement collaboratives. The effectiveness of this approach is unknown. To evaluate the impact of collaborative membership on organizational climate for quality and service quality. Twenty-one clinics, 4 of which participated in a collaborative sponsored by the Institute for Clinical Systems Improvement. Pre-post design. Preassessments occurred 2 months before the collaborative began in January 2009. Postassessments of service quality and climate occurred about 6 months and 1 year, respectively, after the collaborative ended in January 2010. We surveyed clinic employees (eg, physicians, nurses, receptionists, etc.) about the organizational climate and patients about service quality. Prioritization of quality care, high-quality staff relationships, and open communication as indicators of quality-oriented climate and timeliness of care, staff helpfulness, doctor-patient communication, rating of doctor, and willingness to recommend doctor's office as indicators of service quality. There was no significant effect of collaborative membership on quality-oriented climate and mixed effects on service quality. Doctors' ratings improved significantly more in intervention clinics than in control clinics, staff helpfulness improved less, and timeliness of care declined more. Ratings of doctor-patient communication and willingness to recommend doctor were not significantly different between intervention and comparison clinics. Membership in the collaborative provided no significant advantage for improving quality-oriented climate and had equivocal effects on service quality.

  16. Surgical Reconstruction with the Remnant Ligament Improves Joint Position Sense as well as Functional Ankle Instability: A 1-Year Follow-Up Study

    Directory of Open Access Journals (Sweden)

    Kamizato Iwao

    2014-01-01

    Full Text Available Introduction. Chronic functional instability—characterized by repeated ankle inversion sprains and a subjective sensation of instability—is one of the most common residual disabilities after an inversion sprain. However, whether surgical reconstruction improves sensorimotor control has not been reported to date. The purpose of this study was to assess functional improvement of chronic ankle instability after surgical reconstruction using the remnant ligament. Materials and Methods. We performed 10 cases in the intervention group and 20 healthy individuals as the control group. Before and after surgical reconstruction, we evaluated joint position sense and functional ankle instability by means of a questionnaire. Results and Discussion. There was a statistically significant difference between the control and intervention groups before surgical reconstruction. Three months after surgery in the intervention group, the joint position sense was significantly different from those found preoperatively. Before surgery, the mean score of functional ankle instability in the intervention group was almost twice as low. Three months after surgery, however, the score significantly increased. The results showed that surgical reconstruction using the remnant ligament was effective not only for improving mechanical retensioning but also for ameliorating joint position sense and functional ankle instability.

  17. A sparsity-based iterative algorithm for reconstruction of micro-CT images from highly undersampled projection datasets obtained with a synchrotron X-ray source

    Science.gov (United States)

    Melli, S. Ali; Wahid, Khan A.; Babyn, Paul; Cooper, David M. L.; Gopi, Varun P.

    2016-12-01

    Synchrotron X-ray Micro Computed Tomography (Micro-CT) is an imaging technique which is increasingly used for non-invasive in vivo preclinical imaging. However, it often requires a large number of projections from many different angles to reconstruct high-quality images leading to significantly high radiation doses and long scan times. To utilize this imaging technique further for in vivo imaging, we need to design reconstruction algorithms that reduce the radiation dose and scan time without reduction of reconstructed image quality. This research is focused on using a combination of gradient-based Douglas-Rachford splitting and discrete wavelet packet shrinkage image denoising methods to design an algorithm for reconstruction of large-scale reduced-view synchrotron Micro-CT images with acceptable quality metrics. These quality metrics are computed by comparing the reconstructed images with a high-dose reference image reconstructed from 1800 equally spaced projections spanning 180°. Visual and quantitative-based performance assessment of a synthetic head phantom and a femoral cortical bone sample imaged in the biomedical imaging and therapy bending magnet beamline at the Canadian Light Source demonstrates that the proposed algorithm is superior to the existing reconstruction algorithms. Using the proposed reconstruction algorithm to reduce the number of projections in synchrotron Micro-CT is an effective way to reduce the overall radiation dose and scan time which improves in vivo imaging protocols.

  18. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations.

    Science.gov (United States)

    Guziński, Maciej; Waszczuk, Łukasz; Sąsiadek, Marek J

    2016-10-01

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. •With ASiR it is possible to lower radiation dose or improve image quality •Sequentional imaging allows setting scan parameters for brain and posterior-fossa independently •We improved visibility of brainstem structures and decreased radiation dose •Total radiation dose (DLP) was decreased by 19.

  19. A glance at quality score: implication for de novo transcriptome reconstruction of Illumina reads

    Directory of Open Access Journals (Sweden)

    Stanley Kimbung Mbandi

    2014-02-01

    Full Text Available Downstream analyses of short-reads from next-generation sequencing platforms are often preceded by a pre-processing step that removes uncalled and wrongly called bases. Standard approaches rely on their associated base quality scores to retain the read or a portion of it when the score is above a predefined threshold. It is difficult to differentiate sequencing error from biological variation without a reference using quality scores. The effects of quality score based trimming have not been systematically studied in de novo transcriptome assembly. Using RNA-Seq data produced from Illumina, we teased out the effects of quality score base filtering or trimming on de novo transcriptome reconstruction. We showed that assemblies produced from reads subjected to different quality score thresholds contain truncated and missing transfrags when compared to those from untrimmed reads. Our data supports the fact that de novo assembling of untrimmed data is challenging for de Bruijn graph assemblers. However, our results indicates that comparing the assemblies from untrimmed and trimmed read subsets can suggest appropriate filtering parameters and enable selection of the optimum de novo transcriptome assembly in non-model organisms.

  20. Electronic health records improve clinical note quality.

    Science.gov (United States)

    Burke, Harry B; Sessums, Laura L; Hoang, Albert; Becher, Dorothy A; Fontelo, Paul; Liu, Fang; Stephens, Mark; Pangaro, Louis N; O'Malley, Patrick G; Baxi, Nancy S; Bunt, Christopher W; Capaldi, Vincent F; Chen, Julie M; Cooper, Barbara A; Djuric, David A; Hodge, Joshua A; Kane, Shawn; Magee, Charles; Makary, Zizette R; Mallory, Renee M; Miller, Thomas; Saperstein, Adam; Servey, Jessica; Gimbel, Ronald W

    2015-01-01

    The clinical note documents the clinician's information collection, problem assessment, clinical management, and its used for administrative purposes. Electronic health records (EHRs) are being implemented in clinical practices throughout the USA yet it is not known whether they improve the quality of clinical notes. The goal in this study was to determine if EHRs improve the quality of outpatient clinical notes. A five and a half year longitudinal retrospective multicenter quantitative study comparing the quality of handwritten and electronic outpatient clinical visit notes for 100 patients with type 2 diabetes at three time points: 6 months prior to the introduction of the EHR (before-EHR), 6 months after the introduction of the EHR (after-EHR), and 5 years after the introduction of the EHR (5-year-EHR). QNOTE, a validated quantitative instrument, was used to assess the quality of outpatient clinical notes. Its scores can range from a low of 0 to a high of 100. Sixteen primary care physicians with active practices used QNOTE to determine the quality of the 300 patient notes. The before-EHR, after-EHR, and 5-year-EHR grand mean scores (SD) were 52.0 (18.4), 61.2 (16.3), and 80.4 (8.9), respectively, and the change in scores for before-EHR to after-EHR and before-EHR to 5-year-EHR were 18% (pquality scores significantly improved over the 5-year time interval. The EHR significantly improved the overall quality of the outpatient clinical note and the quality of all its elements, including the core and non-core elements. To our knowledge, this is the first study to demonstrate that the EHR significantly improves the quality of clinical notes. © The Author 2014. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  1. Parallel MR image reconstruction using augmented Lagrangian methods.

    Science.gov (United States)

    Ramani, Sathish; Fessler, Jeffrey A

    2011-03-01

    Magnetic resonance image (MRI) reconstruction using SENSitivity Encoding (SENSE) requires regularization to suppress noise and aliasing effects. Edge-preserving and sparsity-based regularization criteria can improve image quality, but they demand computation-intensive nonlinear optimization. In this paper, we present novel methods for regularized MRI reconstruction from undersampled sensitivity encoded data--SENSE-reconstruction--using the augmented Lagrangian (AL) framework for solving large-scale constrained optimization problems. We first formulate regularized SENSE-reconstruction as an unconstrained optimization task and then convert it to a set of (equivalent) constrained problems using variable splitting. We then attack these constrained versions in an AL framework using an alternating minimization method, leading to algorithms that can be implemented easily. The proposed methods are applicable to a general class of regularizers that includes popular edge-preserving (e.g., total-variation) and sparsity-promoting (e.g., l(1)-norm of wavelet coefficients) criteria and combinations thereof. Numerical experiments with synthetic and in vivo human data illustrate that the proposed AL algorithms converge faster than both general-purpose optimization algorithms such as nonlinear conjugate gradient (NCG) and state-of-the-art MFISTA.

  2. LOR-interleaving image reconstruction for PET imaging with fractional-crystal collimation

    International Nuclear Information System (INIS)

    Li, Yusheng; Matej, Samuel; Karp, Joel S; Metzler, Scott D

    2015-01-01

    Positron emission tomography (PET) has become an important modality in medical and molecular imaging. However, in most PET applications, the resolution is still mainly limited by the physical crystal sizes or the detector’s intrinsic spatial resolution. To achieve images with better spatial resolution in a central region of interest (ROI), we have previously proposed using collimation in PET scanners. The collimator is designed to partially mask detector crystals to detect lines of response (LORs) within fractional crystals. A sequence of collimator-encoded LORs is measured with different collimation configurations. This novel collimated scanner geometry makes the reconstruction problem challenging, as both detector and collimator effects need to be modeled to reconstruct high-resolution images from collimated LORs. In this paper, we present a LOR-interleaving (LORI) algorithm, which incorporates these effects and has the advantage of reusing existing reconstruction software, to reconstruct high-resolution images for PET with fractional-crystal collimation. We also develop a 3D ray-tracing model incorporating both the collimator and crystal penetration for simulations and reconstructions of the collimated PET. By registering the collimator-encoded LORs with the collimator configurations, high-resolution LORs are restored based on the modeled transfer matrices using the non-negative least-squares method and EM algorithm. The resolution-enhanced images are then reconstructed from the high-resolution LORs using the MLEM or OSEM algorithm. For validation, we applied the LORI method to a small-animal PET scanner, A-PET, with a specially designed collimator. We demonstrate through simulated reconstructions with a hot-rod phantom and MOBY phantom that the LORI reconstructions can substantially improve spatial resolution and quantification compared to the uncollimated reconstructions. The LORI algorithm is crucial to improve overall image quality of collimated PET, which

  3. How Quality Improvement Practice Evidence Can Advance the Knowledge Base.

    Science.gov (United States)

    OʼRourke, Hannah M; Fraser, Kimberly D

    2016-01-01

    Recommendations for the evaluation of quality improvement interventions have been made in order to improve the evidence base of whether, to what extent, and why quality improvement interventions affect chosen outcomes. The purpose of this article is to articulate why these recommendations are appropriate to improve the rigor of quality improvement intervention evaluation as a research endeavor, but inappropriate for the purposes of everyday quality improvement practice. To support our claim, we describe the differences between quality improvement interventions that occur for the purpose of practice as compared to research. We then carefully consider how feasibility, ethics, and the aims of evaluation each impact how quality improvement interventions that occur in practice, as opposed to research, can or should be evaluated. Recommendations that fit the evaluative goals of practice-based quality improvement interventions are needed to support fair appraisal of the distinct evidence they produce. We describe a current debate on the nature of evidence to assist in reenvisioning how quality improvement evidence generated from practice might complement that generated from research, and contribute in a value-added way to the knowledge base.

  4. Data Quality Assessment and Recommendations to Improve the Quality of Hemodialysis Database

    Directory of Open Access Journals (Sweden)

    Neda Firouraghi

    2018-01-01

    Full Text Available Introduction: Since clinical data contain abnormalities, quality assessment and reporting of data errors are necessary. Data quality analysis consists of developing strategies, making recommendations to avoid future errors and improving the quality of data entry by identifying error types and their causes. Therefore, this approach can be extremely useful to improve the quality of the databases. The aim of this study was to analyze hemodialysis (HD patients’ data in order to improve the quality of data entry and avoid future errors. Method: The study was done on Shiraz University of Medical Sciences HD database in 2015. The database consists of 2367 patients who had at least 12 months follow up (22.34±11.52 months in 2012-2014. Duplicated data were removed; outliers were detected based on statistical methods, expert opinion and the relationship between variables; then, the missing values were handled in 72 variables by using IBM SPSS Statistics 22 in order to improve the quality of the database. According to the results, some recommendations were given to improve the data entry process. Results: The variables had outliers in the range of 0-9.28 percent. Seven variables had missing values over 20 percent and in the others they were between 0 and 19.73 percent. The majority of missing values belong to serum alkaline phosphatase, uric acid, high and low density lipoprotein, total iron binding capacity, hepatitis B surface antibody titer, and parathyroid hormone. The variables with displacement (the values of two or more variables were recorded in the wrong attribute were weight, serum creatinine, blood urea nitrogen, systolic and diastolic blood pressure. These variables may lead to decreased data quality. Conclusion: According to the results and expert opinion, applying some data entry principles, such as defining ranges of values, using the relationship between hemodialysis features, developing alert systems about empty or duplicated data and

  5. The superomedial thigh flap in scrotal reconstruction: Technical steps to improve cosmetic results

    Directory of Open Access Journals (Sweden)

    Ayat Allah Oufkir

    2013-01-01

    Full Text Available The superomedial thigh flap is a reliable and easy method for scrotal reconstruction described in 1980 and infrequently reported in the literature since its description. We used it for four patients presenting scrotal defects after Fournier′s gangrene with some technical modifications to improve the esthetic results and to facilitate the closure of the donor area. We describe the technical steps and the results.

  6. Continuous quality improvement in the ambulatory endoscopy center.

    Science.gov (United States)

    Johanson, John F

    2002-04-01

    What does quality assessment have to do with the practicing gastroenterologist? Why should one spend the time and effort to incorporate CQI activities into an already busy practice? First and foremost, quality improvement should directly benefit the patient by ensuring that they receive the highest quality of care possible. For example, comparing endoscopic use or outcomes, such as procedure success or complications, with national standards or other endoscopists in the same community may identify physicians who could benefit from additional training. Similar analyses may likewise identify outstanding physicians who might serve as resources for other physicians. Surveys of patient satisfaction may reveal deficiencies, which might be unknown to a physician who is otherwise technically excellent; deficiencies that would never have been uncovered by traditional measures of quality. Second, applying the techniques of CQI to study one's own practice can provide a competitive edge when vying for managed care or corporate contracts. In this regard, CQI can be used to document physician or practice performance through tracking of endoscopic use, procedure success and complication rates, and patient satisfaction. Finally, the rising concern among various patient advocacy groups has led to an increased emphasis on quality improvement, and in most cases it is a required activity as part of the accreditation process. Steps to quality improvement There is more to quality improvement than simply selecting and implementing a performance improvement plan. A number of steps have been suggested to achieve fundamental improvement in the quality of medical care [3]. The first is to use outcomes management for improvement rather than for judgment. One of the major criticisms of QA is that it will be used to judge physicians providing care. It is feared that CQI will be used to identify poor performers who will then be punished. This strategy leads to fear and inhibits an honest pursuit

  7. Technological measures to improve automotive product quality

    OpenAIRE

    Gladkov, V.; Kruglov, S.

    2010-01-01

    The paper examines the basic technological measures aimed at improving product quality in automotive industry. While paying due attention to solving organizational and technological problems, including the development of certification systems for production processes, it is also necessary to improve the technical standards of specific technologies, equipment and materials as they largely determine product quality. Special emphasis is given to the importance of improving the production of auto...

  8. An improved muon reconstruction algorithm for INO-ICAL experiment

    International Nuclear Information System (INIS)

    Bhattacharya, Kolahal; MandaI, Naba K.

    2013-01-01

    The charge current interaction of neutrino in INO-ICAL detector will be identified with a muon (μ ± ) in the detector whose kinematics is related with the kinematics of the neutrino. So, muon reconstruction is a very important step in achieving INO physics goals. The existing muon reconstruction package for INO-ICAL has poor performance in specific regimes of experimental interest: (a) for larger zenith angle (θ > 50°), (b) for lower energies (E < 1 GeV); mainly due to poor error propagation scheme insensitive to energy E, angle (θ, φ) and inhomogeneous magnetic field along the muon track. Since, a significant fraction of muons from atmospheric neutrino interactions will have initial energy < 1 GeV and almost uniform distribution in cosθ a robust package for muon reconstruction is essential. We have implemented higher order correction terms in the propagation of the state and error covariance matrices of the Kalman Iter. The algorithm ensures track element merging in most cases and also increases reconstruction efficiency. The performance of this package will be presented in comparison with the previous one. (author)

  9. Framing quality improvement tools and techniques in healthcare the case of improvement leaders' guides.

    Science.gov (United States)

    Millar, Ross

    2013-01-01

    The purpose of this paper is to present a study of how quality improvement tools and techniques are framed within healthcare settings. The paper employs an interpretive approach to understand how quality improvement tools and techniques are mobilised and legitimated. It does so using a case study of the NHS Modernisation Agency Improvement Leaders' Guides in England. Improvement Leaders' Guides were framed within a service improvement approach encouraging the use of quality improvement tools and techniques within healthcare settings. Their use formed part of enacting tools and techniques across different contexts. Whilst this enactment was believed to support the mobilisation of tools and techniques, the experience also illustrated the challenges in distributing such approaches. The paper provides an important contribution in furthering our understanding of framing the "social act" of quality improvement. Given the ongoing emphasis on quality improvement in health systems and the persistent challenges involved, it also provides important information for healthcare leaders globally in seeking to develop, implement or modify similar tools and distribute leadership within health and social care settings.

  10. QUALITY IMPROVEMENT MODEL AT THE MANUFACTURING PROCESS PREPARATION LEVEL

    Directory of Open Access Journals (Sweden)

    Dusko Pavletic

    2009-12-01

    Full Text Available The paper expresses base for an operational quality improvement model at the manufacturing process preparation level. A numerous appropriate related quality assurance and improvement methods and tools are identified. Main manufacturing process principles are investigated in order to scrutinize one general model of manufacturing process and to define a manufacturing process preparation level. Development and introduction of the operational quality improvement model is based on a research conducted and results of methods and tools application possibilities in real manufacturing processes shipbuilding and automotive industry. Basic model structure is described and presented by appropriate general algorithm. Operational quality improvement model developed lays down main guidelines for practical and systematic application of quality improvements methods and tools.

  11. Bringing quality improvement into the intensive care unit.

    Science.gov (United States)

    McMillan, Tracy R; Hyzy, Robert C

    2007-02-01

    During the last several years, many governmental and nongovernmental organizations have championed the application of the principles of quality improvement to the practice of medicine, particularly in the area of critical care. To review the breadth of approaches to quality improvement in the intensive care unit, including measures such as mortality and length of stay, and the use of protocols, bundles, and the role of large, multiple-hospital collaboratives. Several agencies have participated in the application of the quality movement to medicine, culminating in the development of standards such as the intensive care unit core measures of the Joint Commission on Accreditation of Healthcare Organizations. Although "zero defects" may not be possible in all measurable variables of quality in the intensive care unit, several measures, such as catheter-related bloodstream infections, can be significantly reduced through the implementation of improved processes of care, such as care bundles. Large, multiple-center, quality improvement collaboratives, such as the Michigan Keystone Intensive Care Unit Project, may be particularly effective in improving the quality of care by creating a "bandwagon effect" within a geographic region. The quality revolution is having a significant effect in the critical care unit and is likely to be facilitated by the transition to the electronic medical record.

  12. Integrating empowerment evaluation and quality improvement to achieve healthcare improvement outcomes

    Science.gov (United States)

    Wandersman, Abraham; Alia, Kassandra Ann; Cook, Brittany; Ramaswamy, Rohit

    2015-01-01

    While the body of evidence-based healthcare interventions grows, the ability of health systems to deliver these interventions effectively and efficiently lags behind. Quality improvement approaches, such as the model for improvement, have demonstrated some success in healthcare but their impact has been lessened by implementation challenges. To help address these challenges, we describe the empowerment evaluation approach that has been developed by programme evaluators and a method for its application (Getting To Outcomes (GTO)). We then describe how GTO can be used to implement healthcare interventions. An illustrative healthcare quality improvement example that compares the model for improvement and the GTO method for reducing hospital admissions through improved diabetes care is described. We conclude with suggestions for integrating GTO and the model for improvement. PMID:26178332

  13. Clinical investigation of flat panel CT following middle ear reconstruction: a study of 107 patients

    Energy Technology Data Exchange (ETDEWEB)

    Zaoui, K. [University Hospital Heidelberg, Ruprecht Karls University, Department of Otorhinolaryngology, Head and Neck Surgery, Heidelberg (Germany); Kromeier, J. [St. Josefs Hospital, RkK, Department of Radiology, Freiburg (Germany); Neudert, M.; Beleites, T.; Zahnert, T. [University Hospital Dresden, Technical University, Department of Otorhinolaryngology, Head and Neck Surgery, Dresden (Germany); Laszig, R.; Offergeld, C. [University Hospital Freiburg, Albert Ludwigs University, Department of Otorhinolaryngology, Head and Neck Surgery, Freiburg (Germany)

    2014-03-15

    After middle ear reconstruction using partial or total ossicular replacement prostheses (PORP/TORP), an air-bone gap (ABG) may persist because of prosthesis displacement or malposition. So far, CT of the temporal bone has played the main role in the diagnosis of reasons for postoperative insufficient ABG improvement. Recent experimental and clinical studies have evaluated flat panel CT (fpCT) as an alternative imaging technique that provides images with high isovolumetric resolution, fewer metal-induced artefacts and lower irradiation doses. One hundred and seven consecutive patients with chronic otitis media with or without cholesteatoma underwent reconstruction by PORP (n = 52) or TORP (n = 55). All subjects underwent preoperative and postoperative audiometric testing and postoperative fpCT. Statistical evaluation of all 107 patients as well as the sole sub-assembly groups (PORP or TORP) showed a highly significant correlation between hearing improvement and fpCT-determined prosthesis position. FpCT enables detailed postoperative information on patients with middle ear reconstruction. FpCT is a new imaging technique that provides immediate feedback on surgical results after reconstructive middle ear surgery. Specific parameters evaluated by fpCT may serve as a predictive tool for estimated postoperative hearing improvement. Therefore this imaging technique is suitable for postoperative quality control in reconstructive middle ear surgery. (orig.)

  14. Additive manufacturing technology in reconstructive surgery.

    Science.gov (United States)

    Fuller, Scott C; Moore, Michael G

    2016-10-01

    Technological advances have been part and parcel of modern reconstructive surgery, in that practitioners of this discipline are continually looking for innovative ways to perfect their craft and improve patient outcomes. We are currently in a technological climate wherein advances in computers, imaging, and science have coalesced with resulting innovative breakthroughs that are not merely limited to improved outcomes and enhanced patient care, but may provide novel approaches to training the next generation of reconstructive surgeons. New developments in software and modeling platforms, imaging modalities, tissue engineering, additive manufacturing, and customization of implants are poised to revolutionize the field of reconstructive surgery. The interface between technological advances and reconstructive surgery continues to expand. Additive manufacturing techniques continue to evolve in an effort to improve patient outcomes, decrease operative time, and serve as instructional tools for the training of reconstructive surgeons.

  15. The ReACH Collaborative--improving quality home care.

    Science.gov (United States)

    Boyce, Patricia Simino; Pace, Karen B; Lauder, Bonnie; Solomon, Debra A

    2007-08-01

    Research on quality of care has shown that vigorous leadership, clear goals, and compatible incentive systems are critical factors in influencing successful change (Institute of Medicine, 2001). Quality improvement is a complex process, and clinical quality improvement applications are more likely to be effective in organizations that are ready for change and have strong leaders, who are committed to creating and reinforcing a work environment that supports quality goals (Shortell, 1998). Key leadership roles include providing clear and sustained direction, articulating a coherent set of values and incentives to guide group and individual activities, aligning and integrating improvement efforts into organizational priorities, obtaining or freeing up resources to implement improvement activities, and creating a culture of "continuous improvement" that encourages and rewards the pursuit and achievement of shared quality aims (Institute of Medicine, 2001, 70-71). In summary, home health care is a significant and growing sector of the health care system that provides care to millions of vulnerable patients. There seems little doubt that home health agencies want to focus on quality of care issues and provide optimal care to home-based patients. Furthermore, there is a growing awareness of the value for adapting innovative, effective models for improving the culture of home care practice. This awareness stems from the notion that some agencies see quality improvement activities as a way for them to distinguish themselves not only to regulators and customers, but also to meet the cultural and transformational needs to remain viable in a constantly evolving and competitive health care industry.

  16. [Quality assurance and quality improvement in medical practice. Part 3: Clinical audit in medical practice].

    Science.gov (United States)

    Godény, Sándor

    2012-02-05

    The first two articles in the series were about the definition of quality in healthcare, the quality approach, the importance of quality assurance, the advantages of quality management systems and the basic concepts and necessity of evidence based medicine. In the third article the importance and basic steps of clinical audit are summarised. Clinical audit is an integral part of quality assurance and quality improvement in healthcare, that is the responsibility of any practitioner involved in medical practice. Clinical audit principally measures the clinical practice against clinical guidelines, protocols and other professional standards, and sometimes induces changes to ensure that all patients receive care according to principles of the best practice. The clinical audit can be defined also as a quality improvement process that seeks to identify areas for service improvement, develop and carry out plans and actions to improve medical activity and then by re-audit to ensure that these changes have an effect. Therefore, its aims are both to stimulate quality improvement interventions and to assess their impact in order to develop clinical effectiveness. At the end of the article key points of quality assurance and improvement in medical practice are summarised.

  17. A heuristic statistical stopping rule for iterative reconstruction in emission tomography

    International Nuclear Information System (INIS)

    Ben Bouallegue, F.; Mariano-Goulart, D.; Crouzet, J.F.

    2013-01-01

    We propose a statistical stopping criterion for iterative reconstruction in emission tomography based on a heuristic statistical description of the reconstruction process. The method was assessed for maximum likelihood expectation maximization (MLEM) reconstruction. Based on Monte-Carlo numerical simulations and using a perfectly modeled system matrix, our method was compared with classical iterative reconstruction followed by low-pass filtering in terms of Euclidian distance to the exact object, noise, and resolution. The stopping criterion was then evaluated with realistic PET data of a Hoffman brain phantom produced using the Geant4 application in emission tomography (GATE) platform for different count levels. The numerical experiments showed that compared with the classical method, our technique yielded significant improvement of the noise-resolution tradeoff for a wide range of counting statistics compatible with routine clinical settings. When working with realistic data, the stopping rule allowed a qualitatively and quantitatively efficient determination of the optimal image. Our method appears to give a reliable estimation of the optimal stopping point for iterative reconstruction. It should thus be of practical interest as it produces images with similar or better quality than classical post-filtered iterative reconstruction with a mastered computation time. (author)

  18. Shaping the breast in secondary microsurgical breast reconstruction: single- vs. two-esthetic unit reconstruction.

    Science.gov (United States)

    Gravvanis, Andreas; Smith, Roger W

    2010-10-01

    The esthetic outcome is dictated essentially not only by the position, size, and shape of the reconstructed breast, but also by the extra scaring involved. In the present study, we conducted a visual analog scale survey to compare the esthetic outcome in delayed autologous breast reconstruction following two different abdominal flaps inset. Twenty-five patients had their reconstruction using the Single-esthetic Unit principle and were compared with 25 patients that their breast was reconstructed using the Two-Esthetic Unit principle. Photographic images were formulated to a PowerPoint presentation and cosmetic outcomes were assessed from 30 physicians, by means of a Questionnaire and a visual analog scale. Our data showed that the single-esthetic unit breast reconstruction presents significant advantages over the traditional two-esthetic units, due to inconspicuous flap reconstruction, better position of the inframammary fold, and more natural transition from native and reconstructed tissues. Moreover, patient self-evaluation of esthetic outcome and quality of life showed that single-esthetic unit reconstruction is associated with higher patient satisfaction, therefore should be considered the method of choice. © 2010 Wiley-Liss, Inc.

  19. A Simulation-Based Quality Improvement Initiative Improves Pediatric Readiness in Community Hospitals.

    Science.gov (United States)

    Whitfill, Travis; Gawel, Marcie; Auerbach, Marc

    2017-07-17

    The National Pediatric Readiness Project Pediatric Readiness Survey (PRS) measured pediatric readiness in 4149 US emergency departments (EDs) and noted an average score of 69 on a 100-point scale. This readiness score consists of 6 domains: coordination of pediatric patient care (19/100), physician/nurse staffing and training (10/100), quality improvement activities (7/100), patient safety initiatives (14/100), policies and procedures (17/100), and availability of pediatric equipment (33/100). We aimed to assess and improve pediatric emergency readiness scores across Connecticut's hospitals. The aim of this study was to compare the National Pediatric Readiness Project readiness score before and after an in situ simulation-based assessment and quality improvement program in Connecticut hospitals. We leveraged in situ simulations to measure the quality of resuscitative care provided by interprofessional teams to 3 simulated patients (infant septic shock, infant seizure, and child cardiac arrest) presenting to their ED resuscitation bay. Assessments of EDs were made based on a composite quality score that was measured as the sum of 4 distinct domains: (1) adherence to sepsis guidelines, (2) adherence to cardiac arrest guidelines, (3) performance on seizure resuscitation, and (4) teamwork. After the simulation, a detailed report with scores, comparisons to other EDs, and a gap analysis were provided to sites. Based on this report, a regional children's hospital team worked collaboratively with each ED to develop action items and a timeline for improvements. The National Pediatric Readiness Project PRS scores, the primary outcome of this study, were measured before and after participation. Twelve community EDs in Connecticut participated in this project. The PRS scores were assessed before and after the intervention (simulation-based assessment and gap analysis/report-out). The average time between PRS assessments was 21 months. The PRS scores significantly improved 12

  20. Pediatric 320-row cardiac computed tomography using electrocardiogram-gated model-based full iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Shirota, Go; Maeda, Eriko; Namiki, Yoko; Bari, Razibul; Abe, Osamu [The University of Tokyo, Department of Radiology, Graduate School of Medicine, Tokyo (Japan); Ino, Kenji [The University of Tokyo Hospital, Imaging Center, Tokyo (Japan); Torigoe, Rumiko [Toshiba Medical Systems, Tokyo (Japan)

    2017-10-15

    Full iterative reconstruction algorithm is available, but its diagnostic quality in pediatric cardiac CT is unknown. To compare the imaging quality of two algorithms, full and hybrid iterative reconstruction, in pediatric cardiac CT. We included 49 children with congenital cardiac anomalies who underwent cardiac CT. We compared quality of images reconstructed using the two algorithms (full and hybrid iterative reconstruction) based on a 3-point scale for the delineation of the following anatomical structures: atrial septum, ventricular septum, right atrium, right ventricle, left atrium, left ventricle, main pulmonary artery, ascending aorta, aortic arch including the patent ductus arteriosus, descending aorta, right coronary artery and left main trunk. We evaluated beam-hardening artifacts from contrast-enhancement material using a 3-point scale, and we evaluated the overall image quality using a 5-point scale. We also compared image noise, signal-to-noise ratio and contrast-to-noise ratio between the algorithms. The overall image quality was significantly higher with full iterative reconstruction than with hybrid iterative reconstruction (3.67±0.79 vs. 3.31±0.89, P=0.0072). The evaluation scores for most of the gross structures were higher with full iterative reconstruction than with hybrid iterative reconstruction. There was no significant difference between full and hybrid iterative reconstruction for the presence of beam-hardening artifacts. Image noise was significantly lower in full iterative reconstruction, while signal-to-noise ratio and contrast-to-noise ratio were significantly higher in full iterative reconstruction. The diagnostic quality was superior in images with cardiac CT reconstructed with electrocardiogram-gated full iterative reconstruction. (orig.)

  1. Pediatric 320-row cardiac computed tomography using electrocardiogram-gated model-based full iterative reconstruction

    International Nuclear Information System (INIS)

    Shirota, Go; Maeda, Eriko; Namiki, Yoko; Bari, Razibul; Abe, Osamu; Ino, Kenji; Torigoe, Rumiko

    2017-01-01

    Full iterative reconstruction algorithm is available, but its diagnostic quality in pediatric cardiac CT is unknown. To compare the imaging quality of two algorithms, full and hybrid iterative reconstruction, in pediatric cardiac CT. We included 49 children with congenital cardiac anomalies who underwent cardiac CT. We compared quality of images reconstructed using the two algorithms (full and hybrid iterative reconstruction) based on a 3-point scale for the delineation of the following anatomical structures: atrial septum, ventricular septum, right atrium, right ventricle, left atrium, left ventricle, main pulmonary artery, ascending aorta, aortic arch including the patent ductus arteriosus, descending aorta, right coronary artery and left main trunk. We evaluated beam-hardening artifacts from contrast-enhancement material using a 3-point scale, and we evaluated the overall image quality using a 5-point scale. We also compared image noise, signal-to-noise ratio and contrast-to-noise ratio between the algorithms. The overall image quality was significantly higher with full iterative reconstruction than with hybrid iterative reconstruction (3.67±0.79 vs. 3.31±0.89, P=0.0072). The evaluation scores for most of the gross structures were higher with full iterative reconstruction than with hybrid iterative reconstruction. There was no significant difference between full and hybrid iterative reconstruction for the presence of beam-hardening artifacts. Image noise was significantly lower in full iterative reconstruction, while signal-to-noise ratio and contrast-to-noise ratio were significantly higher in full iterative reconstruction. The diagnostic quality was superior in images with cardiac CT reconstructed with electrocardiogram-gated full iterative reconstruction. (orig.)

  2. Error Evaluation in a Stereovision-Based 3D Reconstruction System

    Directory of Open Access Journals (Sweden)

    Kohler Sophie

    2010-01-01

    Full Text Available The work presented in this paper deals with the performance analysis of the whole 3D reconstruction process of imaged objects, specifically of the set of geometric primitives describing their outline and extracted from a pair of images knowing their associated camera models. The proposed analysis focuses on error estimation for the edge detection process, the starting step for the whole reconstruction procedure. The fitting parameters describing the geometric features composing the workpiece to be evaluated are used as quality measures to determine error bounds and finally to estimate the edge detection errors. These error estimates are then propagated up to the final 3D reconstruction step. The suggested error analysis procedure for stereovision-based reconstruction tasks further allows evaluating the quality of the 3D reconstruction. The resulting final error estimates enable lastly to state if the reconstruction results fulfill a priori defined criteria, for example, fulfill dimensional constraints including tolerance information, for vision-based quality control applications for example.

  3. Functional outcome of gastrointestinal tract and quality of life after esophageal reconstruction of esophagus cancer

    International Nuclear Information System (INIS)

    Manochehr Aghajanzade; Feizollah Safarpour; M Reza Koohsari; Hadi Tozandehgani; Ghanaei, Farborz M; Bodaghi, Sadigheh M

    2009-01-01

    Information about functional outcome and quality of life after esophagectomy and esophageal reconstruction (ER) for the treatment of esophageal cancer, as evaluated by the patients themselves is limited. We aimed to study the post-surgical outcome of such patients to detect for the development of any complications that may arise from the surgery as well as to evaluate their quality of life following the surgery. From 1993 to 2003, 240 patients with stage 1, 2, or 3 esophageal carcinoma underwent esophagectomy at Razi Teaching Hospital located in the north of Iran. Of these, 192 patients filled out a questionnaire during a 2-year period (ranging from 12 to 48 months after surgical reconstruction). Among them, there were 134 men (69%) and 58 women (31%), and the mean age at the time of ER was 48 years (ranging from 22 to 75 years). Transhiatal esophagectomy, extended esophagectomy (three field operation), and Ivor-Lewis resection were done in 142 (73.95%), 30 (15.62%), and 20 patients (10.42%), respectively. Intestinal continuity after esophageal resection was established with stomach in 154 patients (80%), colon in 28 patients (14%), and small bowel in 10 patients (5.2%). Cervical anastomosis was established in 172 patients (89.6%), while intrathoracic anastomosis was performed in 20 patients (10.4%). After ER, 66 patients (34.4%) suffered from dysphagia to solids and 50 patients (26%) required at least one or three postoperative dilatations for alleviation of symptoms. Gastroesophageal reflux was seen in 32 patients (16.66%) and was more common in thoracic anastomosis patients than in cervical anastomosis patients. Heartburn was present in 33 cases (17%), 30 of whom required medication (37%). The number of meals per day was three to four in 116 patients (60%), more than four in 51 patients (29%), and less than three in 19 patients (9.82%). The number of bowel movement per day increased in 52 patients (27%), decreased in 60 cases (31%), and unchanged in 80 patients

  4. Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction.

    Science.gov (United States)

    Huang, Hsuan-Ming; Hsiao, Ing-Tsung

    2017-01-01

    Over the past decade, image quality in low-dose computed tomography has been greatly improved by various compressive sensing- (CS-) based reconstruction methods. However, these methods have some disadvantages including high computational cost and slow convergence rate. Many different speed-up techniques for CS-based reconstruction algorithms have been developed. The purpose of this paper is to propose a fast reconstruction framework that combines a CS-based reconstruction algorithm with several speed-up techniques. First, total difference minimization (TDM) was implemented using the soft-threshold filtering (STF). Second, we combined TDM-STF with the ordered subsets transmission (OSTR) algorithm for accelerating the convergence. To further speed up the convergence of the proposed method, we applied the power factor and the fast iterative shrinkage thresholding algorithm to OSTR and TDM-STF, respectively. Results obtained from simulation and phantom studies showed that many speed-up techniques could be combined to greatly improve the convergence speed of a CS-based reconstruction algorithm. More importantly, the increased computation time (≤10%) was minor as compared to the acceleration provided by the proposed method. In this paper, we have presented a CS-based reconstruction framework that combines several acceleration techniques. Both simulation and phantom studies provide evidence that the proposed method has the potential to satisfy the requirement of fast image reconstruction in practical CT.

  5. Denoising of B1+ field maps for noise-robust image reconstruction in electrical properties tomography

    International Nuclear Information System (INIS)

    Michel, Eric; Hernandez, Daniel; Cho, Min Hyoung; Lee, Soo Yeol

    2014-01-01

    Purpose: To validate the use of adaptive nonlinear filters in reconstructing conductivity and permittivity images from the noisy B 1 + maps in electrical properties tomography (EPT). Methods: In EPT, electrical property images are computed by taking Laplacian of the B 1 + maps. To mitigate the noise amplification in computing the Laplacian, the authors applied adaptive nonlinear denoising filters to the measured complex B 1 + maps. After the denoising process, they computed the Laplacian by central differences. They performed EPT experiments on phantoms and a human brain at 3 T along with corresponding EPT simulations on finite-difference time-domain models. They evaluated the EPT images comparing them with the ones obtained by previous EPT reconstruction methods. Results: In both the EPT simulations and experiments, the nonlinear filtering greatly improved the EPT image quality when evaluated in terms of the mean and standard deviation of the electrical property values at the regions of interest. The proposed method also improved the overall similarity between the reconstructed conductivity images and the true shapes of the conductivity distribution. Conclusions: The nonlinear denoising enabled us to obtain better-quality EPT images of the phantoms and the human brain at 3 T

  6. MO-DE-207A-05: Dictionary Learning Based Reconstruction with Low-Rank Constraint for Low-Dose Spectral CT

    International Nuclear Information System (INIS)

    Xu, Q; Liu, H; Xing, L; Yu, H; Wang, G

    2016-01-01

    Purpose: Spectral CT enabled by an energy-resolved photon-counting detector outperforms conventional CT in terms of material discrimination, contrast resolution, etc. One reconstruction method for spectral CT is to generate a color image from a reconstructed component in each energy channel. However, given the radiation dose, the number of photons in each channel is limited, which will result in strong noise in each channel and affect the final color reconstruction. Here we propose a novel dictionary learning method for spectral CT that combines dictionary-based sparse representation method and the patch based low-rank constraint to simultaneously improve the reconstruction in each channel and to address the inter-channel correlations to further improve the reconstruction. Methods: The proposed method has two important features: (1) guarantee of the patch based sparsity in each energy channel, which is the result of the dictionary based sparse representation constraint; (2) the explicit consideration of the correlations among different energy channels, which is realized by patch-by-patch nuclear norm-based low-rank constraint. For each channel, the dictionary consists of two sub-dictionaries. One is learned from the average of the images in all energy channels, and the other is learned from the average of the images in all energy channels except the current channel. With average operation to reduce noise, these two dictionaries can effectively preserve the structural details and get rid of artifacts caused by noise. Combining them together can express all structural information in current channel. Results: Dictionary learning based methods can obtain better results than FBP and the TV-based method. With low-rank constraint, the image quality can be further improved in the channel with more noise. The final color result by the proposed method has the best visual quality. Conclusion: The proposed method can effectively improve the image quality of low-dose spectral

  7. MO-DE-207A-05: Dictionary Learning Based Reconstruction with Low-Rank Constraint for Low-Dose Spectral CT

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Q [Xi’an Jiaotong University, Xi’an (China); Stanford University School of Medicine, Stanford, CA (United States); Liu, H; Xing, L [Stanford University School of Medicine, Stanford, CA (United States); Yu, H [University of Massachusetts Lowell, Lowell, MA (United States); Wang, G [Rensselaer Polytechnic Instute., Troy, NY (United States)

    2016-06-15

    Purpose: Spectral CT enabled by an energy-resolved photon-counting detector outperforms conventional CT in terms of material discrimination, contrast resolution, etc. One reconstruction method for spectral CT is to generate a color image from a reconstructed component in each energy channel. However, given the radiation dose, the number of photons in each channel is limited, which will result in strong noise in each channel and affect the final color reconstruction. Here we propose a novel dictionary learning method for spectral CT that combines dictionary-based sparse representation method and the patch based low-rank constraint to simultaneously improve the reconstruction in each channel and to address the inter-channel correlations to further improve the reconstruction. Methods: The proposed method has two important features: (1) guarantee of the patch based sparsity in each energy channel, which is the result of the dictionary based sparse representation constraint; (2) the explicit consideration of the correlations among different energy channels, which is realized by patch-by-patch nuclear norm-based low-rank constraint. For each channel, the dictionary consists of two sub-dictionaries. One is learned from the average of the images in all energy channels, and the other is learned from the average of the images in all energy channels except the current channel. With average operation to reduce noise, these two dictionaries can effectively preserve the structural details and get rid of artifacts caused by noise. Combining them together can express all structural information in current channel. Results: Dictionary learning based methods can obtain better results than FBP and the TV-based method. With low-rank constraint, the image quality can be further improved in the channel with more noise. The final color result by the proposed method has the best visual quality. Conclusion: The proposed method can effectively improve the image quality of low-dose spectral

  8. Quality Rating and Improvement System State Evaluations and Research

    Science.gov (United States)

    Ferguson, Daniel

    2016-01-01

    A quality rating and improvement system (QRIS) is a method used by states and local jurisdictions to assess the level of quality of child care and early education programs, improve quality, and convey quality ratings to parents and other consumers. A typical QRIS incorporates the following components: quality standards for participating providers;…

  9. Nationwide quality improvement in lung cancer care

    DEFF Research Database (Denmark)

    Jakobsen, Erik Winther; Green, Anders; Oesterlind, Kell

    2013-01-01

    To improve prognosis and quality of lung cancer care the Danish Lung Cancer Group has developed a strategy consisting of national clinical guidelines and a clinical quality and research database. The first edition of our guidelines was published in 1998 and our national lung cancer registry...... was opened for registrations in 2000. This article describes methods and results obtained by multidisciplinary collaboration and illustrates how quality of lung cancer care can be improved by establishing and monitoring result and process indicators....

  10. Early Surgical Site Infection Following Tissue Expander Breast Reconstruction with or without Acellular Dermal Matrix: National Benchmarking Using National Surgical Quality Improvement Program

    Directory of Open Access Journals (Sweden)

    Sebastian Winocour

    2015-03-01

    Full Text Available BackgroundSurgical site infections (SSIs result in significant patient morbidity following immediate tissue expander breast reconstruction (ITEBR. This study determined a single institution's 30-day SSI rate and benchmarked it against that among national institutions participating in the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP.MethodsWomen who underwent ITEBR with/without acellular dermal matrix (ADM were identified using the ACS-NSQIP database between 2005 and 2011. Patient characteristics associated with the 30-day SSI rate were determined, and differences in rates between our institution and the national database were assessed.Results12,163 patients underwent ITEBR, including 263 at our institution. SSIs occurred in 416 (3.4% patients nationwide excluding our institution, with lower rates observed at our institution (1.9%. Nationwide, SSIs were significantly more common in ITEBR patients with ADM (4.5% compared to non-ADM patients (3.2%, P=0.005, and this trend was observed at our institution (2.1% vs. 1.6%, P=1.00. A multivariable analysis of all institutions identified age ≥50 years (odds ratio [OR], 1.4; confidence interval [CI], 1.1-1.7, body mass index ≥30 kg/m2 vs. 4.25 hours (OR, 1.9; CI, 1.5-2.4 as risk factors for SSIs. Our institutional SSI rate was lower than the nationwide rate (OR, 0.4; CI, 0.2-1.1, although this difference was not statistically significant (P=0.07.ConclusionsThe 30-day SSI rate at our institution in patients who underwent ITEBR was lower than the nation. SSIs occurred more frequently in procedures involving ADM both nationally and at our institution.

  11. Evaluation of image reconstruction methods for 123I-MIBG-SPECT. A rank-order study

    International Nuclear Information System (INIS)

    Soederberg, Marcus; Mattsson, Soeren; Oddstig, Jenny; Uusijaervi-Lizana, Helena; Leide-Svegborn, Sigrid; Valind, Sven; Thorsson, Ola; Garpered, Sabine; Prautzsch, Tilmann; Tischenko, Oleg

    2012-01-01

    Background: There is an opportunity to improve the image quality and lesion detectability in single photon emission computed tomography (SPECT) by choosing an appropriate reconstruction method and optimal parameters for the reconstruction. Purpose: To optimize the use of the Flash 3D reconstruction algorithm in terms of equivalent iteration (EI) number (number of subsets times the number of iterations) and to compare with two recently developed reconstruction algorithms ReSPECT and orthogonal polynomial expansion on disc (OPED) for application on 123 I-metaiodobenzylguanidine (MIBG)-SPECT. Material and Methods: Eleven adult patients underwent SPECT 4 h and 14 patients 24 h after injection of approximately 200 MBq 123 I-MIBG using a Siemens Symbia T6 SPECT/CT. Images were reconstructed from raw data using the Flash 3D algorithm at eight different EI numbers. The images were ranked by three experienced nuclear medicine physicians according to their overall impression of the image quality. The obtained optimal images were then compared in one further visual comparison with images reconstructed using the ReSPECT and OPED algorithms. Results: The optimal EI number for Flash 3D was determined to be 32 for acquisition 4 h and 24 h after injection. The average rank order (best first) for the different reconstructions for acquisition after 4 h was: Flash 3D 32 > ReSPECT > Flash 3D 64 > OPED, and after 24 h: Flash 3D 16 > ReSPECT > Flash 3D 32 > OPED. A fair level of inter-observer agreement concerning optimal EI number and reconstruction algorithm was obtained, which may be explained by the different individual preferences of what is appropriate image quality. Conclusion: Using Siemens Symbia T6 SPECT/CT and specified acquisition parameters, Flash 3D 32 (4 h) and Flash 3D 16 (24 h), followed by ReSPECT, were assessed to be the preferable reconstruction algorithms in visual assessment of 123 I-MIBG images

  12. Laboratory quality improvement in Thailand's northernmost provinces.

    Science.gov (United States)

    Kanitvittaya, S; Suksai, U; Suksripanich, O; Pobkeeree, V

    2010-01-01

    In Thailand nearly 1000 public health laboratories serve 65 million people. A qualified indicator of a good quality laboratory is Thailand Medical Technology Council certification. Consequently, Chiang Rai Regional Medical Sciences Center established a development program for laboratory certification for 29 laboratories in the province. This paper seeks to examine this issue. The goal was to improve laboratory service quality by voluntary participation, peer review, training and compliance with standards. The program consisted of specific activities. Training and workshops to update laboratory staffs' quality management knowledge were organized. Staff in each laboratory performed a self-assessment using a standard check-list to evaluate ten laboratory management areas. Chiang Rai Regional Medical Sciences Center staff supported the distribution of quality materials and documents. They provided calibration services for laboratory equipment. Peer groups performed an internal audit and successful laboratories received Thailand Medical Technology Council certification. By December 2007, eight of the 29 laboratories had improved quality sufficiently to be certified. Factors that influenced laboratories' readiness for quality improvement included the number of staff, their knowledge, budget and staff commitment to the process. Moreover, the support of each hospital's laboratory working group or network was essential for success. There was no clear policy for supporting the program. Laboratories voluntarily conducted quality management using existing resources. A bottom-up approach to this kind of project can be difficult to accomplish. Laboratory professionals can work together to illustrate and highlight outcomes for top-level health officials. A top-down, practical approach would be much less difficult to implement. Quality certification is a critical step for laboratory staff, which also encourages them to aspire to international quality standards like ISO. The

  13. Image quality and radiation dose of low dose coronary CT angiography in obese patients: Sinogram affirmed iterative reconstruction versus filtered back projection

    International Nuclear Information System (INIS)

    Wang, Rui; Schoepf, U. Joseph; Wu, Runze; Reddy, Ryan P.; Zhang, Chuanchen; Yu, Wei; Liu, Yi; Zhang, Zhaoqi

    2012-01-01

    Purpose: To investigate the image quality and radiation dose of low radiation dose CT coronary angiography (CTCA) using sinogram affirmed iterative reconstruction (SAFIRE) compared with standard dose CTCA using filtered back-projection (FBP) in obese patients. Materials and methods: Seventy-eight consecutive obese patients were randomized into two groups and scanned using a prospectively ECG-triggered step-and-shot (SAS) CTCA protocol on a dual-source CT scanner. Thirty-nine patients (protocol A) were examined using a routine radiation dose protocol at 120 kV and images were reconstructed with FBP (protocol A). Thirty-nine patients (protocol B) were examined using a low dose protocol at 100 kV and images were reconstructed with SAFIRE. Two blinded observers independently assessed the image quality of each coronary segment using a 4-point scale (1 = non-diagnostic, 4 = excellent) and measured the objective parameters image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Radiation dose was calculated. Results: The coronary artery image quality scores, image noise, SNR and CNR were not significantly different between protocols A and B (all p > 0.05), with image quality scores of 3.51 ± 0.70 versus 3.55 ± 0.47, respectively. The effective radiation dose was significantly lower in protocol B (4.41 ± 0.83 mSv) than that in protocol A (8.83 ± 1.74 mSv, p < 0.01). Conclusion: Compared with standard dose CTCA using FBP, low dose CTCA using SAFIRE can maintain diagnostic image quality with 50% reduction of radiation dose.

  14. Evaluation of imaging protocol for ECT based on CS image reconstruction algorithm

    International Nuclear Information System (INIS)

    Zhou Xiaolin; Yun Mingkai; Cao Xuexiang; Liu Shuangquan; Wang Lu; Huang Xianchao; Wei Long

    2014-01-01

    Single-photon emission computerized tomography and positron emission tomography are essential medical imaging tools, for which the sampling angle number and scan time should be carefully chosen to give a good compromise between image quality and radiopharmaceutical dose. In this study, the image quality of different acquisition protocols was evaluated via varied angle number and count number per angle with Monte Carlo simulation data. It was shown that, when similar imaging counts were used, the factor of acquisition counts was more important than that of the sampling number in emission computerized tomography. To further reduce the activity requirement and the scan duration, an iterative image reconstruction algorithm for limited-view and low-dose tomography based on compressed sensing theory has been developed. The total variation regulation was added to the reconstruction process to improve the signal to noise Ratio and reduce artifacts caused by the limited angle sampling. Maximization of the maximum likelihood of the estimated image and the measured data and minimization of the total variation of the image are alternatively implemented. By using this advanced algorithm, the reconstruction process is able to achieve image quality matching or exceed that of normal scans with only half of the injection radiopharmaceutical dose. (authors)

  15. Key interventions and quality indicators for quality improvement of STEMI care: a RAND Delphi survey.

    Science.gov (United States)

    Aeyels, Daan; Sinnaeve, Peter R; Claeys, Marc J; Gevaert, Sofie; Schoors, Danny; Sermeus, Walter; Panella, Massimiliano; Coeckelberghs, Ellen; Bruyneel, Luk; Vanhaecht, Kris

    2017-12-13

    Identification, selection and validation of key interventions and quality indicators for improvement of in hospital quality of care for ST-elevated myocardial infarction (STEMI) patients. A structured literature review was followed by a RAND Delphi Survey. A purposively selected multidisciplinary expert panel of cardiologists, nurse managers and quality managers selected and validated key interventions and quality indicators prior for quality improvement for STEMI. First, 34 experts (76% response rate) individually assessed the appropriateness of items to quality improvement on a nine point Likert scale. Twenty-seven key interventions, 16 quality indicators at patient level and 27 quality indicators at STEMI care programme level were selected. Eighteen additional items were suggested. Experts received personal feedback, benchmarking their score with group results (response rate, mean, median and content validity index). Consequently, 32 experts (71% response rate) openly discussed items with an item-content validity index above 75%. By consensus, the expert panel validated a final set of 25 key interventions, 13 quality indicators at patient level and 20 quality indicators at care programme level prior for improvement of in hospital care for STEMI. A structured literature review and multidisciplinary expertise was combined to validate a set of key interventions and quality indicators prior for improvement of care for STEMI. The results allow researchers and hospital staff to evaluate and support quality improvement interventions in a large cohort within the context of a health care system.

  16. Quality Function Deployment Application for Improving Quality of Education in Business Schools

    Science.gov (United States)

    Sagnak, Muhittin; Ada, Nesrin; Kazancoglu, Yigit; Tayaksi, Cansu

    2017-01-01

    There is an increasing competition between universities globally to attract students. At this point, to compete, it is imperative for the universities to improve the quality of education provided for their stakeholders, including students, parents, and employers. For improving the quality of education, first of all, the universities should make…

  17. IMPROVING QUALITY MANAGEMENT IN PANIFICATION

    Directory of Open Access Journals (Sweden)

    Cornelia Petroman

    2010-12-01

    Full Text Available Consumers of panification products (as well as consumers of any other type of product or service are concerned about the quality of the products they purchase. Implementing the quality management system in the food industry is not compulsory, but it can bring about numerous, palpable benefits, particularly in reducing the amount of acryl amide. It is a modern system allowing the management analysis aiming at checking and reaching the goals to define new objectives, and the continuous improvement of the quality of processes and products.

  18. Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children

    International Nuclear Information System (INIS)

    Yoon, Haesung; Kim, Myung-Joon; Shin, Hyun Joo; Kim, Hyun Gi; Lee, Mi-Jung; Yoon, Choon-Sik; Choi, Jiin

    2015-01-01

    New CT reconstruction techniques may help reduce the burden of ionizing radiation. To quantify radiation dose reduction when performing pediatric chest CT using a low-dose protocol and 50% adaptive statistical iterative reconstruction (ASIR) compared with age/gender-matched chest CT using a conventional dose protocol and reconstructed with filtered back projection (control group) and to determine its effect on image quality in normal weight and overweight children. We retrospectively reviewed 40 pediatric chest CT (M:F = 21:19; range: 0.1-17 years) in both groups. Radiation dose was compared between the two groups using paired Student's t-test. Image quality including noise, sharpness, artifacts and diagnostic acceptability was subjectively assessed by three pediatric radiologists using a four-point scale (superior, average, suboptimal, unacceptable). Eight children in the ASIR group and seven in the control group were overweight. All radiation dose parameters were significantly lower in the ASIR group (P < 0.01) with a greater than 57% dose reduction in overweight children. Image noise was higher in the ASIR group in both normal weight and overweight children. Only one scan in the ASIR group (1/40, 2.5%) was rated as diagnostically suboptimal and there was no unacceptable study. In both normal weight and overweight children, the ASIR technique is associated with a greater than 57% mean dose reduction, without significantly impacting diagnostic image quality in pediatric chest CT examinations. However, CT scans in overweight children may have a greater noise level, even when using the ASIR technique. (orig.)

  19. Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Haesung; Kim, Myung-Joon; Shin, Hyun Joo; Kim, Hyun Gi; Lee, Mi-Jung [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Seoul (Korea, Republic of); Yoon, Choon-Sik [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Choi, Jiin [Yonsei University College of Medicine, Biostatistics Collaboration Unit, Seoul (Korea, Republic of)

    2015-03-01

    New CT reconstruction techniques may help reduce the burden of ionizing radiation. To quantify radiation dose reduction when performing pediatric chest CT using a low-dose protocol and 50% adaptive statistical iterative reconstruction (ASIR) compared with age/gender-matched chest CT using a conventional dose protocol and reconstructed with filtered back projection (control group) and to determine its effect on image quality in normal weight and overweight children. We retrospectively reviewed 40 pediatric chest CT (M:F = 21:19; range: 0.1-17 years) in both groups. Radiation dose was compared between the two groups using paired Student's t-test. Image quality including noise, sharpness, artifacts and diagnostic acceptability was subjectively assessed by three pediatric radiologists using a four-point scale (superior, average, suboptimal, unacceptable). Eight children in the ASIR group and seven in the control group were overweight. All radiation dose parameters were significantly lower in the ASIR group (P < 0.01) with a greater than 57% dose reduction in overweight children. Image noise was higher in the ASIR group in both normal weight and overweight children. Only one scan in the ASIR group (1/40, 2.5%) was rated as diagnostically suboptimal and there was no unacceptable study. In both normal weight and overweight children, the ASIR technique is associated with a greater than 57% mean dose reduction, without significantly impacting diagnostic image quality in pediatric chest CT examinations. However, CT scans in overweight children may have a greater noise level, even when using the ASIR technique. (orig.)

  20. Image reconstruction of fluorescent molecular tomography based on the tree structured Schur complement decomposition

    Directory of Open Access Journals (Sweden)

    Wang Jiajun

    2010-05-01

    Full Text Available Abstract Background The inverse problem of fluorescent molecular tomography (FMT often involves complex large-scale matrix operations, which may lead to unacceptable computational errors and complexity. In this research, a tree structured Schur complement decomposition strategy is proposed to accelerate the reconstruction process and reduce the computational complexity. Additionally, an adaptive regularization scheme is developed to improve the ill-posedness of the inverse problem. Methods The global system is decomposed level by level with the Schur complement system along two paths in the tree structure. The resultant subsystems are solved in combination with the biconjugate gradient method. The mesh for the inverse problem is generated incorporating the prior information. During the reconstruction, the regularization parameters are adaptive not only to the spatial variations but also to the variations of the objective function to tackle the ill-posed nature of the inverse problem. Results Simulation results demonstrate that the strategy of the tree structured Schur complement decomposition obviously outperforms the previous methods, such as the conventional Conjugate-Gradient (CG and the Schur CG methods, in both reconstruction accuracy and speed. As compared with the Tikhonov regularization method, the adaptive regularization scheme can significantly improve ill-posedness of the inverse problem. Conclusions The methods proposed in this paper can significantly improve the reconstructed image quality of FMT and accelerate the reconstruction process.