WorldWideScience

Sample records for implantation system cais

  1. Particulated articular cartilage: CAIS and DeNovo NT.

    Science.gov (United States)

    Farr, Jack; Cole, Brian J; Sherman, Seth; Karas, Vasili

    2012-03-01

    Cartilage Autograft Implantation System (CAIS; DePuy/Mitek, Raynham, MA) and DeNovo Natural Tissue (NT; ISTO, St. Louis, MO) are novel treatment options for focal articular cartilage defects in the knee. These methods involve the implantation of particulated articular cartilage from either autograft or juvenile allograft donor, respectively. In the laboratory and in animal models, both CAIS and DeNovo NT have demonstrated the ability of the transplanted cartilage cells to "escape" from the extracellular matrix, migrate, multiply, and form a new hyaline-like cartilage tissue matrix that integrates with the surrounding host tissue. In clinical practice, the technique for both CAIS and DeNovo NT is straightforward, requiring only a single surgery to affect cartilage repair. Clinical experience is limited, with short-term studies demonstrating both procedures to be safe, feasible, and effective, with improvements in subjective patient scores, and with magnetic resonance imaging evidence of good defect fill. While these treatment options appear promising, prospective randomized controlled studies are necessary to refine the indications and contraindications for both CAIS and DeNovo NT.

  2. An Object-Oriented Architecture for a Web-Based CAI System.

    Science.gov (United States)

    Nakabayashi, Kiyoshi; Hoshide, Takahide; Seshimo, Hitoshi; Fukuhara, Yoshimi

    This paper describes the design and implementation of an object-oriented World Wide Web-based CAI (Computer-Assisted Instruction) system. The goal of the design is to provide a flexible CAI/ITS (Intelligent Tutoring System) framework with full extendibility and reusability, as well as to exploit Web-based software technologies such as JAVA, ASP (a…

  3. CAI System with Multi-Media Text Through Web Browser for NC Lathe Programming

    Science.gov (United States)

    Mizugaki, Yoshio; Kikkawa, Koichi; Mizui, Masahiko; Kamijo, Keisuke

    A new Computer Aided Instruction (CAI) system for NC lathe programming has been developed with use of multi-media texts including movies, animations, pictures, sound and texts through Web browser. Although many CAI systems developed previously for NC programming consist of text-based instructions, it is difficult for beginners to learn NC programming with use of them. In the developed CAI system, multi-media texts are adopted for the help of users' understanding, and it is available through Web browser anytime and anywhere. Also the error log is automatically recorded for the future references. According to the NC programming coded by a user, the movement of the NC lathe is animated and shown in the monitor screen in front of the user. If its movement causes the collision between a cutting tool and the lathe, some sound and the caution remark are generated. If the user makes mistakes some times at a certain stage in learning NC, the corresponding suggestion is shown in the form of movies, animations, and so forth. By using the multimedia texts, users' attention is kept concentrated during a training course. In this paper, the configuration of the CAI system is explained and the actual procedures for users to learn the NC programming are also explained too. Some beginners tested this CAI system and their results are illustrated and discussed from the viewpoint of the efficiency and usefulness of this CAI system. A brief conclusion is also mentioned.

  4. Development of an intelligent CAI system for a distributed processing environment

    International Nuclear Information System (INIS)

    Fujii, M.; Sasaki, K.; Ohi, T.; Itoh, T.

    1993-01-01

    In order to operate a nuclear power plant optimally in both normal and abnormal situations, the operators are trained using an operator training simulator in addition to classroom instruction. Individual instruction using a CAI (Computer-Assisted Instruction) system has become popular as a method of learning plant information, such as plant dynamics, operational procedures, plant systems, plant facilities, etc. The outline is described of a proposed network-based intelligent CAI system (ICAI) incorporating multi-medial PWR plant dynamics simulation, teaching aids and educational record management using the following environment: existing standard workstations and graphic workstations with a live video processing function, TCP/IP protocol of Unix through Ethernet and X window system. (Z.S.) 3 figs., 2 refs

  5. NALDA (Naval Aviation Logistics Data Analysis) CAI (computer aided instruction)

    Energy Technology Data Exchange (ETDEWEB)

    Handler, B.H. (Oak Ridge K-25 Site, TN (USA)); France, P.A.; Frey, S.C.; Gaubas, N.F.; Hyland, K.J.; Lindsey, A.M.; Manley, D.O. (Oak Ridge Associated Universities, Inc., TN (USA)); Hunnum, W.H. (North Carolina Univ., Chapel Hill, NC (USA)); Smith, D.L. (Memphis State Univ., TN (USA))

    1990-07-01

    Data Systems Engineering Organization (DSEO) personnel developed a prototype computer aided instruction CAI system for the Naval Aviation Logistics Data Analysis (NALDA) system. The objective of this project was to provide a CAI prototype that could be used as an enhancement to existing NALDA training. The CAI prototype project was performed in phases. The task undertaken in Phase I was to analyze the problem and the alternative solutions and to develop a set of recommendations on how best to proceed. The findings from Phase I are documented in Recommended CAI Approach for the NALDA System (Duncan et al., 1987). In Phase II, a structured design and specifications were developed, and a prototype CAI system was created. A report, NALDA CAI Prototype: Phase II Final Report, was written to record the findings and results of Phase II. NALDA CAI: Recommendations for an Advanced Instructional Model, is comprised of related papers encompassing research on computer aided instruction CAI, newly developing training technologies, instructional systems development, and an Advanced Instructional Model. These topics were selected because of their relevancy to the CAI needs of NALDA. These papers provide general background information on various aspects of CAI and give a broad overview of new technologies and their impact on the future design and development of training programs. The paper within have been index separately elsewhere.

  6. SOLAR WIND IMPLANTATION MODEL FOR 10Be IN CALCIUM-ALUMINUM INCLUSIONS

    International Nuclear Information System (INIS)

    Bricker, Glynn E.; Caffee, Marc W.

    2010-01-01

    We propose a model for the incorporation of 10 Be within calcium-aluminum inclusions (CAIs) in primitive carbonaceous meteorites. In this model, 10 Be is produced by energetic particle reactions in the proto-solar atmosphere of a more active proto-Sun characterized by energetic particle fluxes higher than contemporary particle fluxes. This 10 Be is incorporated into the solar wind that is then implanted into CAI precursor material. This production mechanism is operational in the contemporary solar system implanting 10 Be in lunar materials. The contemporary production rate of 10 Be at the surface of the Sun is ∼0.1 10 Be cm -2 s -1 . Scaling up the contemporary 10 Be production in the proto-Sun by a factor of 10 5 would increase the production rate to 10 410 Be cm -2 s -1 . Using this enhanced production value in conjunction with refractory mass inflow rates at 0.06 AU from the proto-Sun we model 10 Be concentrations in CAI precursors. We calculate the content of solar-wind-implanted 10 Be would have been of the order of 10 1210 Be g -1 in CAIs, consistent with initial 10 Be content found from boron-beryllium isotopic systematics in CAIs.

  7. Computers for Your Classroom: CAI and CMI.

    Science.gov (United States)

    Thomas, David B.; Bozeman, William C.

    1981-01-01

    The availability of compact, low-cost computer systems provides a means of assisting classroom teachers in the performance of their duties. Computer-assisted instruction (CAI) and computer-managed instruction (CMI) are two applications of computer technology with which school administrators should become familiar. CAI is a teaching medium in which…

  8. E-CAI: a novel server to estimate an expected value of Codon Adaptation Index (eCAI

    Directory of Open Access Journals (Sweden)

    Garcia-Vallvé Santiago

    2008-01-01

    Full Text Available Abstract Background The Codon Adaptation Index (CAI is a measure of the synonymous codon usage bias for a DNA or RNA sequence. It quantifies the similarity between the synonymous codon usage of a gene and the synonymous codon frequency of a reference set. Extreme values in the nucleotide or in the amino acid composition have a large impact on differential preference for synonymous codons. It is thence essential to define the limits for the expected value of CAI on the basis of sequence composition in order to properly interpret the CAI and provide statistical support to CAI analyses. Though several freely available programs calculate the CAI for a given DNA sequence, none of them corrects for compositional biases or provides confidence intervals for CAI values. Results The E-CAI server, available at http://genomes.urv.es/CAIcal/E-CAI, is a web-application that calculates an expected value of CAI for a set of query sequences by generating random sequences with G+C and amino acid content similar to those of the input. An executable file, a tutorial, a Frequently Asked Questions (FAQ section and several examples are also available. To exemplify the use of the E-CAI server, we have analysed the codon adaptation of human mitochondrial genes that codify a subunit of the mitochondrial respiratory chain (excluding those genes that lack a prokaryotic orthologue and are encoded in the nuclear genome. It is assumed that these genes were transferred from the proto-mitochondrial to the nuclear genome and that its codon usage was then ameliorated. Conclusion The E-CAI server provides a direct threshold value for discerning whether the differences in CAI are statistically significant or whether they are merely artifacts that arise from internal biases in the G+C composition and/or amino acid composition of the query sequences.

  9. CAIs in Semarkona (LL3.0)

    Science.gov (United States)

    Mishra, R. K.; Simon, J. I.; Ross, D. K.; Marhas, K. K.

    2016-01-01

    Calcium, Aluminum-rich inclusions (CAIs) are the first forming solids of the Solar system. Their observed abundance, mean size, and mineralogy vary quite significantly between different groups of chondrites. These differences may reflect the dynamics and distinct cosmochemical conditions present in the region(s) of the protoplanetary disk from which each type likely accreted. Only about 11 such objects have been found in L and LL type while another 57 have been found in H type ordinary chondrites, compared to thousands in carbonaceous chondrites. At issue is whether the rare CAIs contained in ordinary chondrites truly reflect a distinct population from the inclusions commonly found in other chondrite types. Semarkona (LL3.00) (fall, 691 g) is the most pristine chondrite available in our meteorite collection. Here we report petrography and mineralogy of 3 CAIs from Semarkona

  10. Generative Computer Assisted Instruction: An Application of Artificial Intelligence to CAI.

    Science.gov (United States)

    Koffman, Elliot B.

    Frame-oriented computer-assisted instruction (CAI) systems dominate the field, but these mechanized programed texts utilize the computational power of the computer to a minimal degree and are difficult to modify. Newer, generative CAI systems which are supplied with a knowledge of subject matter can generate their own problems and solutions, can…

  11. Numerical simulation and validation of SI-CAI hybrid combustion in a CAI/HCCI gasoline engine

    Science.gov (United States)

    Wang, Xinyan; Xie, Hui; Xie, Liyan; Zhang, Lianfang; Li, Le; Chen, Tao; Zhao, Hua

    2013-02-01

    SI-CAI hybrid combustion, also known as spark-assisted compression ignition (SACI), is a promising concept to extend the operating range of CAI (Controlled Auto-Ignition) and achieve the smooth transition between spark ignition (SI) and CAI in the gasoline engine. In this study, a SI-CAI hybrid combustion model (HCM) has been constructed on the basis of the 3-Zones Extended Coherent Flame Model (ECFM3Z). An ignition model is included to initiate the ECFM3Z calculation and induce the flame propagation. In order to precisely depict the subsequent auto-ignition process of the unburned fuel and air mixture independently after the initiation of flame propagation, the tabulated chemistry concept is adopted to describe the auto-ignition chemistry. The methodology for extracting tabulated parameters from the chemical kinetics calculations is developed so that both cool flame reactions and main auto-ignition combustion can be well captured under a wider range of thermodynamic conditions. The SI-CAI hybrid combustion model (HCM) is then applied in the three-dimensional computational fluid dynamics (3-D CFD) engine simulation. The simulation results are compared with the experimental data obtained from a single cylinder VVA engine. The detailed analysis of the simulations demonstrates that the SI-CAI hybrid combustion process is characterised with the early flame propagation and subsequent multi-site auto-ignition around the main flame front, which is consistent with the optical results reported by other researchers. Besides, the systematic study of the in-cylinder condition reveals the influence mechanism of the early flame propagation on the subsequent auto-ignition.

  12. A risk management approach to CAIS development

    Science.gov (United States)

    Hart, Hal; Kerner, Judy; Alden, Tony; Belz, Frank; Tadman, Frank

    1986-01-01

    The proposed DoD standard Common APSE Interface Set (CAIS) was developed as a framework set of interfaces that will support the transportability and interoperability of tools in the support environments of the future. While the current CAIS version is a promising start toward fulfilling those goals and current prototypes provide adequate testbeds for investigations in support of completing specifications for a full CAIS, there are many reasons why the proposed CAIS might fail to become a usable product and the foundation of next-generation (1990'S) project support environments such as NASA's Space Station software support environment. The most critical threats to the viability and acceptance of the CAIS include performance issues (especially in piggybacked implementations), transportability, and security requirements. To make the situation worse, the solution to some of these threats appears to be at conflict with the solutions to others.

  13. The Relevance of AI Research to CAI.

    Science.gov (United States)

    Kearsley, Greg P.

    This article provides a tutorial introduction to Artificial Intelligence (AI) research for those involved in Computer Assisted Instruction (CAI). The general theme is that much of the current work in AI, particularly in the areas of natural language understanding systems, rule induction, programming languages, and socratic systems, has important…

  14. Thermal and chemical evolution in the early solar system as recorded by FUN CAIs: Part I - Petrology, mineral chemistry, and isotopic composition of Allende FUN CAI CMS-1

    Science.gov (United States)

    Williams, C. D.; Ushikubo, T.; Bullock, E. S.; Janney, P. E.; Hines, R. R.; Kita, N. T.; Hervig, R. L.; MacPherson, G. J.; Mendybaev, R. A.; Richter, F. M.; Wadhwa, M.

    2017-03-01

    Detailed petrologic, geochemical and isotopic analyses of a new FUN CAI from the Allende CV3 meteorite (designated CMS-1) indicate that it formed by extensive melting and evaporation of primitive precursor material(s). The precursor material(s) condensed in a 16O-rich region (δ17O and δ18O ∼ -49‰) of the inner solar nebula dominated by gas of solar composition at total pressures of ∼10-3-10-6 bar. Subsequent melting of the precursor material(s) was accompanied by evaporative loss of magnesium, silicon and oxygen resulting in large mass-dependent isotope fractionations in these elements (δ25Mg = 30.71-39.26‰, δ29Si = 14.98-16.65‰, and δ18O = -41.57 to -15.50‰). This evaporative loss resulted in a bulk composition similar to that of compact Type A and Type B CAIs, but very distinct from the composition of the original precursor condensate(s). Kinetic fractionation factors and the measured mass-dependent fractionation of silicon and magnesium in CMS-1 suggest that ∼80% of the silicon and ∼85% of the magnesium were lost from its precursor material(s) through evaporative processes. These results suggest that the precursor material(s) of normal and FUN CAIs condensed in similar environments, but subsequently evolved under vastly different conditions such as total gas pressure. The chemical and isotopic differences between normal and FUN CAIs could be explained by sorting of early solar system materials into distinct physical and chemical regimes, in conjunction with discrete heating events, within the protoplanetary disk.

  15. A multielement isotopic study of refractory FUN and F CAIs: Mass-dependent and mass-independent isotope effects

    Science.gov (United States)

    Kööp, Levke; Nakashima, Daisuke; Heck, Philipp R.; Kita, Noriko T.; Tenner, Travis J.; Krot, Alexander N.; Nagashima, Kazuhide; Park, Changkun; Davis, Andrew M.

    2018-01-01

    Calcium-aluminum-rich inclusions (CAIs) are the oldest dated objects that formed inside the Solar System. Among these are rare, enigmatic objects with large mass-dependent fractionation effects (F CAIs), which sometimes also have large nucleosynthetic anomalies and a low initial abundance of the short-lived radionuclide 26Al (FUN CAIs). We have studied seven refractory hibonite-rich CAIs and one grossite-rich CAI from the Murchison (CM2) meteorite for their oxygen, calcium, and titanium isotopic compositions. The 26Al-26Mg system was also studied in seven of these CAIs. We found mass-dependent heavy isotope enrichment in all measured elements, but never simultaneously in the same CAI. The data are hard to reconcile with a single-stage melt evaporation origin and may require reintroduction or reequilibration for magnesium, oxygen and titanium after evaporation for some of the studied CAIs. The initial 26Al/27Al ratios inferred from model isochrons span a range from <1 × 10-6 to canonical (∼5 × 10-5). The CAIs show a mutual exclusivity relationship between inferred incorporation of live 26Al and the presence of resolvable anomalies in 48Ca and 50Ti. Furthermore, a relationship exists between 26Al incorporation and Δ17O in the hibonite-rich CAIs (i.e., 26Al-free CAIs have resolved variations in Δ17O, while CAIs with resolved 26Mg excesses have Δ17O values close to -23‰). Only the grossite-rich CAI has a relatively enhanced Δ17O value (∼-17‰) in spite of a near-canonical 26Al/27Al. We interpret these data as indicating that fractionated hibonite-rich CAIs formed over an extended time period and sampled multiple stages in the isotopic evolution of the solar nebula, including: (1) an 26Al-poor nebula with large positive and negative anomalies in 48Ca and 50Ti and variable Δ17O; (2) a stage of 26Al-admixture, during which anomalies in 48Ca and 50Ti had been largely diluted and a Δ17O value of ∼-23‰ had been achieved in the CAI formation region; and (3

  16. CAI and training system for the emergency operation procedure in the advanced thermal reactor, FUGEN

    International Nuclear Information System (INIS)

    Kozaki, T.; Imanaga, K.; Nakamura, S.; Maeda, K.; Sakurai, N.; Miyamoto, M.

    2003-01-01

    In the Advanced Thermal Reactor (ATR ) of the JNC, 'FUGEN', a symptom based Emergency Operating Procedure (EOF) was introduced in order to operate Fugen more safely and it became necessary for the plant operators to master the EOF. However it took a lot of time for the instructor to teach the EOP to operators and to train them. Thus, we have developed a Computer Aided Instruction (CAI) and Training System for the EOP, by which the operators can learn the EOP and can be trained. This system has two major functions, i.e., CAI and training. In the CAI function, there are three learning courses, namely, the EOP procedure, the simulation with guidance and Q and A, and the free simulation. In the training function, all of necessary control instruments (indicators, switches, annunciators and so forth) and physics models for the EOP training are simulated so that the trainees can be trained for all of the EOPs. In addition, 50 kinds of malfunction models are installed in order to perform appropriate accident scenarios for the EOP. The training of the EOP covers the range from AOO (Anticipated Operational Occurrence) to Over-DBAs (Design Based Accidents). This system is built in three personal computers that are connected by the computer network. One of the computers is expected to be used for the instructor and the other two are for the trainees. The EOP is composed of eight guidelines, such as 'Reactor Control' and 'Depression and Cooling', and the operation screens which are corresponded to the guidelines are respectively provided. According to the trial, we have estimated that the efficiency of the learning and the training would be improved about 30% for the trainee and about 75% for the instructor in the actual learning and training. (author)

  17. Developing the Coach Analysis and Intervention System (CAIS): establishing validity and reliability of a computerised systematic observation instrument.

    Science.gov (United States)

    Cushion, Christopher; Harvey, Stephen; Muir, Bob; Nelson, Lee

    2012-01-01

    We outline the evolution of a computerised systematic observation tool and describe the process for establishing the validity and reliability of this new instrument. The Coach Analysis and Interventions System (CAIS) has 23 primary behaviours related to physical behaviour, feedback/reinforcement, instruction, verbal/non-verbal, questioning and management. The instrument also analyses secondary coach behaviour related to performance states, recipient, timing, content and questioning/silence. The CAIS is a multi-dimensional and multi-level mechanism able to provide detailed and contextualised data about specific coaching behaviours occurring in complex and nuanced coaching interventions and environments that can be applied to both practice sessions and competition.

  18. Stable Magnesium Isotope Variation in Melilite Mantle of Allende Type B1 CAI EK 459-5-1

    Science.gov (United States)

    Kerekgyarto, A. G.; Jeffcoat, C. R.; Lapen, T. J.; Andreasen, R.; Righter, M.; Ross, D. K.

    2014-01-01

    Ca-Al-rich inclusions (CAIs) are the earliest formed crystalline material in our solar system and they record early Solar System processes. Here we present petrographic and delta Mg-25 data of melilite mantles in a Type B1 CAI that records early solar nebular processes.

  19. A Model Driven Question-Answering System for a CAI Environment. Final Report (July 1970 to May 1972).

    Science.gov (United States)

    Brown, John S.; And Others

    A question answering system which permits a computer-assisted instruction (CAI) student greater initiative in the variety of questions he can ask is described. A method is presented to represent the dynamic processes of a subject matter area by augmented finite state automata, which permits efficient inferencing about dynamic processes and…

  20. The Vibrio cholerae quorum-sensing autoinducer CAI-1: analysis of the biosynthetic enzyme CqsA

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, R.; Bolitho, M; Higgins, D; Lu, W; Ng, W; Jeffrey, P; Rabinowitz, J; Semmelhack, M; Hughson, F; Bassler, B

    2009-01-01

    Vibrio cholerae, the bacterium that causes the disease cholera, controls virulence factor production and biofilm development in response to two extracellular quorum-sensing molecules, called autoinducers. The strongest autoinducer, called CAI-1 (for cholera autoinducer-1), was previously identified as (S)-3-hydroxytridecan-4-one. Biosynthesis of CAI-1 requires the enzyme CqsA. Here, we determine the CqsA reaction mechanism, identify the CqsA substrates as (S)-2-aminobutyrate and decanoyl coenzyme A, and demonstrate that the product of the reaction is 3-aminotridecan-4-one, dubbed amino-CAI-1. CqsA produces amino-CAI-1 by a pyridoxal phosphate-dependent acyl-CoA transferase reaction. Amino-CAI-1 is converted to CAI-1 in a subsequent step via a CqsA-independent mechanism. Consistent with this, we find cells release {ge}100 times more CAI-1 than amino-CAI-1. Nonetheless, V. cholerae responds to amino-CAI-1 as well as CAI-1, whereas other CAI-1 variants do not elicit a quorum-sensing response. Thus, both CAI-1 and amino-CAI-1 have potential as lead molecules in the development of an anticholera treatment.

  1. Coordinated Oxygen Isotopic and Petrologic Studies of CAIS Record Varying Composition of Protosolar

    Science.gov (United States)

    Simon, Justin I.; Matzel, J. E. P.; Simon, S. B.; Weber, P. K.; Grossman, L.; Ross, D. K.; Hutcheon, I. D.

    2012-01-01

    Ca-, Al-rich inclusions (CAIs) record the O-isotope composition of Solar nebular gas from which they grew [1]. High spatial resolution O-isotope measurements afforded by ion microprobe analysis across the rims and margin of CAIs reveal systematic variations in (Delta)O-17 and suggest formation from a diversity of nebular environments [2-4]. This heterogeneity has been explained by isotopic mixing between the O-16-rich Solar reservoir [6] and a second O-16-poor reservoir (probably nebular gas) with a "planetary-like" isotopic composition [e.g., 1, 6-7], but the mechanism and location(s) where these events occur within the protoplanetary disk remain uncertain. The orientation of large and systematic variations in (Delta)O-17 reported by [3] for a compact Type A CAI from the Efremovka reduced CV3 chondrite differs dramatically from reports by [4] of a similar CAI, A37 from the Allende oxidized CV3 chondrite. Both studies conclude that CAIs were exposed to distinct, nebular O-isotope reservoirs, implying the transfer of CAIs among different settings within the protoplanetary disk [4]. To test this hypothesis further and the extent of intra-CAI O-isotopic variation, a pristine compact Type A CAI, Ef-1 from Efremovka, and a Type B2 CAI, TS4 from Allende were studied. Our new results are equally intriguing because, collectively, O-isotopic zoning patterns in the CAIs indicate a progressive and cyclic record. The results imply that CAIs were commonly exposed to multiple environments of distinct gas during their formation. Numerical models help constrain conditions and duration of these events.

  2. CAI: Overcoming Attitude Barriers.

    Science.gov (United States)

    Netusil, Anton J.; Kockler, Lois H.

    During each of two school quarters, approximately 60 college students enrolled in a mathematics course were randomly assigned to an experimental group or a control group. The control group received instruction by the lecture method only; the experimental group received the same instruction, except that six computer-assisted instruction (CAI) units…

  3. The Instructional Use of CAI in the Education of the Mentally Retarded.

    Science.gov (United States)

    Winters, John J., Jr.; And Others

    Computer assisted instruction (CAI) studies with the mentally retarded in the United States and Canada reveal that the retarded benefit from CAI in academic and social skills. Their learning is enhanced to the same extent as that of the nonretarded. CAI can be cost-effective, especially with the reduced costs of mini and micro-computers; however,…

  4. The Impact of Different Support Vectors on GOSAT-2 CAI-2 L2 Cloud Discrimination

    Directory of Open Access Journals (Sweden)

    Yu Oishi

    2017-11-01

    Full Text Available Greenhouse gases Observing SATellite-2 (GOSAT-2 will be launched in fiscal year 2018. GOSAT-2 will be equipped with two sensors: the Thermal and Near-infrared Sensor for Carbon Observation (TANSO-Fourier Transform Spectrometer 2 (FTS-2 and the TANSO-Cloud and Aerosol Imager 2 (CAI-2. CAI-2 is a push-broom imaging sensor that has forward- and backward-looking bands to observe the optical properties of aerosols and clouds and to monitor the status of urban air pollution and transboundary air pollution over oceans, such as PM2.5 (particles less than 2.5 micrometers in diameter. CAI-2 has important applications for cloud discrimination in each direction. The Cloud and Aerosol Unbiased Decision Intellectual Algorithm (CLAUDIA1, which applies sequential threshold tests to features is used for GOSAT CAI L2 cloud flag processing. If CLAUDIA1 is used with CAI-2, it is necessary to optimize the thresholds in accordance with CAI-2. However, CLAUDIA3 with support vector machines (SVM, a supervised pattern recognition method, was developed, and then we applied CLAUDIA3 for GOSAT-2 CAI-2 L2 cloud discrimination processing. Thus, CLAUDIA3 can automatically find the optimized boundary between clear and cloudy areas. Improvements in CLAUDIA3 using CAI (CLAUDIA3-CAI continue to be made. In this study, we examined the impact of various support vectors (SV on GOSAT-2 CAI-2 L2 cloud discrimination by analyzing (1 the impact of the choice of different time periods for the training data and (2 the impact of different generation procedures for SV on the cloud discrimination efficiency. To generate SV for CLAUDIA3-CAI from MODIS data, there are two times at which features are extracted, corresponding to CAI bands. One procedure is equivalent to generating SV using CAI data. Another procedure generates SV for MODIS cloud discrimination at the beginning, and then extracts decision function, thresholds, and SV corresponding to CAI bands. Our results indicated the following

  5. Oxygen isotope variations at the margin of a CAI records circulation within the solar nebula.

    Science.gov (United States)

    Simon, Justin I; Hutcheon, Ian D; Simon, Steven B; Matzel, Jennifer E P; Ramon, Erick C; Weber, Peter K; Grossman, Lawrence; DePaolo, Donald J

    2011-03-04

    Micrometer-scale analyses of a calcium-, aluminum-rich inclusion (CAI) and the characteristic mineral bands mantling the CAI reveal that the outer parts of this primitive object have a large range of oxygen isotope compositions. The variations are systematic; the relative abundance of (16)O first decreases toward the CAI margin, approaching a planetary-like isotopic composition, then shifts to extremely (16)O-rich compositions through the surrounding rim. The variability implies that CAIs probably formed from several oxygen reservoirs. The observations support early and short-lived fluctuations of the environment in which CAIs formed, either because of transport of the CAIs themselves to distinct regions of the solar nebula or because of varying gas composition near the proto-Sun.

  6. Perancangan Perangkat Lunak Media Pembelajaran Menggunakan Computer Assisted Instruction (CAI untuk Pembelajaran Ilmu Tajwid Berbasis Web

    Directory of Open Access Journals (Sweden)

    Fenny Purwani

    2016-03-01

    Full Text Available Strategi penggunaan Computer Assisted Instruction (CAI sebagai media pembelajaran dibutuhkan untuk mengatasi permasalahan yang muncul dalam proses pembelajaran. Pembelajaran yang dikemas dengan baik memberikan dampak yang positif dalam memajukan potensi pada diri manusia. CAI sebagai media pembelajaran berbasis computer dibangun sebagai pelengkap dan pendukung metode pembelajaran yang selama ini hanya menggunakan metode ceramah, diskusi informasi dan demonstrasi. Tujuan penelitian ini adalah merancang dan membangun media pembelajaran CAI yang interaktif dengan berbasis Web. Kemudian hasilnya berupa rancangan CAI dengan model tutorial, serta dilengkapi dengan latihan soal-soal dari materi yang diberikan. Perancangan CAI ini kemudian digunakan untuk media pembelajaran ilmu Tajwid dengan komputer. Strategic use of Computer Assisted Instruction (CAI as a learning media needed to overcome the problems that appeared in the learning process. Learning that was packaged well gave a positive impact in advancing the potential in human beings. CAI as a computer-based learning media was built to complement and support the learning method which as long as only used the speech, discussions, information and demonstrations method. The purpose of this study was to design and build learning media of CAI which was interactive with Web-based. Then the result was a design of CAI with tutorial model and completed with practicing questions from the material provided. This CAI design was then used for learning media of Tajwid with computer.

  7. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  8. Cognitive Assessment Interview (CAI): Validity as a co-primary measure of cognition across phases of schizophrenia.

    Science.gov (United States)

    Ventura, Joseph; Subotnik, Kenneth L; Ered, Arielle; Hellemann, Gerhard S; Nuechterlein, Keith H

    2016-04-01

    Progress has been made in developing interview-based measures for the assessment of cognitive functioning, such as the Cognitive Assessment Interview (CAI), as co-primary measures that compliment objective neurocognitive assessments and daily functioning. However, a few questions remain, including whether the relationships with objective cognitive measures and daily functioning are high enough to justify the CAI as an co-primary measure and whether patient-only assessments are valid. Participants were first-episode schizophrenia patients (n=60) and demographically-similar healthy controls (n=35), chronic schizophrenia patients (n=38) and demographically similar healthy controls (n=19). Participants were assessed at baseline with an interview-based measure of cognitive functioning (CAI), a test of objective cognitive functioning, functional capacity, and role functioning at baseline, and in the first episode patients again 6 months later (n=28). CAI ratings were correlated with objective cognitive functioning, functional capacity, and functional outcomes in first-episode schizophrenia patients at similar magnitudes as in chronic patients. Comparisons of first-episode and chronic patients with healthy controls indicated that the CAI sensitively detected deficits in schizophrenia. The relationship of CAI Patient-Only ratings with objective cognitive functioning, functional capacity, and daily functioning were comparable to CAI Rater scores that included informant information. These results confirm in an independent sample the relationship of the CAI ratings with objectively measured cognition, functional capacity, and role functioning. Comparison of schizophrenia patients with healthy controls further validates the CAI as an co-primary measure of cognitive deficits. Also, CAI change scores were strongly related to objective cognitive change indicating sensitivity to change. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. INAA of CAIs from the Maralinga CK4 chondrite: Effects of parent body thermal metamorphism

    Science.gov (United States)

    Lindstrom, D. J.; Keller, L. P.; Martinez, R. R.

    1993-01-01

    Maralinga is an anomalous CK4 carbonaceous chondrite which contains numerous Ca-, Al-rich inclusions (CAI's) unlike the other members of the CK group. These CAI's are characterized by abundant green hercynitic spinel intergrown with plagioclase and high-Ca clinopyroxene, and a total lack of melilite. Instrumental Neutron Activation Analysis (INAA) was used to further characterize the meteorite, with special focus on the CAI's. High sensitivity INAA was done on eight sample disks about 100-150 microns in diameter obtained from a normal 30 micron thin section with a diamond microcoring device. The CAI's are enriched by 60-70X bulk meteorite values in Zn, suggesting that the substantial exchange of Fe for Mg that made the spinel in the CAI's hercynitic also allowed efficient scavenging of Zn from the rest of the meteorite during parent body thermal metamorphism. Less mobile elements appear to have maintained their initial heterogeneity.

  10. Implant retention systems for implant-retained overdentures.

    Science.gov (United States)

    Laverty, D P; Green, D; Marrison, D; Addy, L; Thomas, M B M

    2017-03-10

    Implant retained overdentures are being increasingly utilised in both general and specialist practice to rehabilitate patients with missing teeth, particularly those that are edentate. This article aims to inform the reader of a variety of retention systems that are available to retain an implant overdenture and to understand how these systems work, their advantages and disadvantages and to outline some of the clinical and treatment planning considerations involved in selecting the most appropriate retention system for patients.

  11. The Range of Initial 10Be/9Be Ratios in the Early Solar System: A Re-Assessment Based on Analyses of New CAIs and Melilite Composition Glass Standards

    Science.gov (United States)

    Dunham, E.; Wadhwa, M.; Liu, M.-C.

    2017-07-01

    We report a more accurate range of initial 10Be/9Be in CAIs including FUN CAI CMS-1 from Allende (CV3) and a new CAI from NWA 5508 (CV3) using melilite composition glass standards; we suggest 10Be is largely produced by irradiation in the nebula.

  12. Precision of fit between implant impression coping and implant replica pairs for three implant systems.

    Science.gov (United States)

    Nicoll, Roxanna J; Sun, Albert; Haney, Stephan; Turkyilmaz, Ilser

    2013-01-01

    The fabrication of an accurately fitting implant-supported fixed prosthesis requires multiple steps, the first of which is assembling the impression coping on the implant. An imprecise fit of the impression coping on the implant will cause errors that will be magnified in subsequent steps of prosthesis fabrication. The purpose of this study was to characterize the 3-dimensional (3D) precision of fit between impression coping and implant replica pairs for 3 implant systems. The selected implant systems represent the 3 main joint types used in implant dentistry: external hexagonal, internal trilobe, and internal conical. Ten impression copings and 10 implant replicas from each of the 3 systems, B (Brånemark System), R (NobelReplace Select), and A (NobelActive) were paired. A standardized aluminum test body was luted to each impression coping, and the corresponding implant replica was embedded in a stone base. A coordinate measuring machine was used to quantify the maximum range of displacement in a vertical direction as a function of the tightening force applied to the guide pin. Maximum angular displacement in a horizontal plane was measured as a function of manual clockwise or counterclockwise rotation. Vertical and rotational positioning was analyzed by using 1-way analysis of variance (ANOVA). The Fisher protected least significant difference (PLSD) multiple comparisons test of the means was applied when the F-test in the ANOVA was significant (α=.05). The mean and standard deviation for change in the vertical positioning of impression copings was 4.3 ±2.1 μm for implant system B, 2.8 ±4.2 μm for implant system R, and 20.6 ±8.8 μm for implant system A. The mean and standard deviation for rotational positioning was 3.21 ±0.98 degrees for system B, 2.58 ±1.03 degrees for system R, and 5.30 ±0.79 degrees for system A. The P-value for vertical positioning between groups A and B and between groups A and R was <.001. No significant differences were found for

  13. NWA10758: A New CV3 Chondrite Bearing a Giant CAI with Hibonite-Rich Wark-Lovering Rim

    Science.gov (United States)

    Ross, D. K.; Simon, J. I.; Zolensky, M.

    2017-01-01

    Northwest Africa (NWA) 10758 is a newly identified carbonaceous chondrite that is a Bali-like oxidized CV3. The large Ca-Al rich inclusion (CAI) in this sample is approx. 2.4 x 1.4 cm. The CAI is transitional in composition between type A and type B, with interior mineralogy dominated by melilite, plus less abundant spinel and Al-Ti rich diopside, and only very minor anorthite (Fig. 1A). This CAI is largely free of secondary alteration in the exposed section we examined, with almost no nepheline, sodalite or Ca-Fe silicates. The Wark-Lovering (WL) rim on this CAI is dominated by hibonite, with lower abundances of spinel and perovskite, and with hibonite locally overlain by melilite plus perovskite (as in Fig. 1B). Note that the example shown in 1B is exceptional. Around most of the CAI, hibonite + spinel + perovskite form the WL rim, without overlying melilite. The WL rim can be unusually thick, ranging from approx. 20 microns up to approx. 150 microns. A well-developed, stratified accretionary rim infills embayments of the CAI, and thins over protuberances in the convoluted CAI surface.

  14. Structural basis of Na+-independent and cooperative substrate/product antiport in CaiT

    NARCIS (Netherlands)

    Schulze, Sabrina; Köster, Stefan; Geldmacher, Ulrike; Terwisscha van Scheltinga, Anke C.; Kühlbrandt, Werner

    2010-01-01

    Transport of solutes across biological membranes is performed by specialized secondary transport proteins in the lipid bilayer, and is essential for life. Here we report the structures of the sodium-independent carnitine/butyrobetaine antiporter CaiT from Proteus mirabilis (PmCaiT) at 2.3-Å and from

  15. A new system of implant abutment connection: how to improve a two piece implant system sealing.

    Science.gov (United States)

    Grecchi, F; DI Girolamo, M; Cura, F; Candotto, V; Carinci, F

    2017-01-01

    Implant dentistry has become one of the most successful dentistry techniques for replacing missing teeth. The success rate of implant dentistry is above 80%. However, peri-implantitis is a later complication of implant dentistry that if untreated, can lead to implant loss. One of the hypotized causes of peri-implantis is the bacterial leakage at the level of implant-abutment connection. Bacterial leakage is favored to the presence of a micro gap at the implant-abutment interface, allowing microorganisms to penetrate and colonize the inner part of the implant leading to biofilm accumulation and consequently to peri-implantitis development. To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Implants were immerged in a bacterial culture for twenty-four hours and then bacteria amount was measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 9%. The reported results are better to those of previous studies carried out on different implant systems. Until now, none implant-abutment system has been proven to seal the gap between implant and abutment.

  16. 電腦輔助教學與個別教學結合: 電腦輔助教學課堂應用初探 Computer-Assisted Instruction Under the Management of Individualized Instruction: A Classroom Management Approach of CAI

    Directory of Open Access Journals (Sweden)

    Sunny S. J. Lin

    1988-03-01

    Full Text Available 無First reviews the development of Computer. Assisted Instruction (CAI in Taiwan. This study describes the training of teachers from different levels of schools to design CAI coursewares, and the planning of CAI courseware bank possesses 2,000 supplemental coursewares. Some CAI's c1assroom application system should be carefully established to prevent the easy abuse of a CAI courseware as an instructional plan. The study also claims to steer CAI in our elemantary and secondary education could rely on the mastery learning as the instructional plan. In this case, CAI must limit its role as the formative test and remedial material only. In the higher education , the Keller's Personalized System of Instruction could be an effective c1assroom management system. Therefore, CAI will offer study guide and formative test only. Using these 2 instructional system may enhance student's achievement , and speed up the learning rate at the same time. Combining with individualized instruction and CAI will be one of the most workable approach in current c1assroom . The author sets up an experiment 10 varify their effectiveness and efficiency in the near future.

  17. Ca-Fe and Alkali-Halide Alteration of an Allende Type B CAI: Aqueous Alteration in Nebular or Asteroidal Settings

    Science.gov (United States)

    Ross, D. K.; Simon, J. I.; Simon, S. B.; Grossman, L.

    2012-01-01

    Ca-Fe and alkali-halide alteration of CAIs is often attributed to aqueous alteration by fluids circulating on asteroidal parent bodies after the various chondritic components have been assembled, although debate continues about the roles of asteroidal vs. nebular modification processes [1-7]. Here we report de-tailed observations of alteration products in a large Type B2 CAI, TS4 from Allende, one of the oxidized subgroup of CV3s, and propose a speculative model for aqueous alteration of CAIs in a nebular setting. Ca-Fe alteration in this CAI consists predominantly of end-member hedenbergite, end-member andradite, and compositionally variable, magnesian high-Ca pyroxene. These phases are strongly concentrated in an unusual "nodule" enclosed within the interior of the CAI (Fig. 1). The Ca, Fe-rich nodule superficially resembles a clast that pre-dated and was engulfed by the CAI, but closer inspection shows that relic spinel grains are enclosed in the nodule, and corroded CAI primary phases interfinger with the Fe-rich phases at the nodule s margins. This CAI also contains abundant sodalite and nepheline (alkali-halide) alteration that occurs around the rims of the CAI, but also penetrates more deeply into the CAI. The two types of alteration (Ca-Fe and alkali-halide) are adjacent, and very fine-grained Fe-rich phases are associated with sodalite-rich regions. Both types of alteration appear to be replacive; if that is true, it would require substantial introduction of Fe, and transport of elements (Ti, Al and Mg) out of the nodule, and introduction of Na and Cl into alkali-halide rich zones. Parts of the CAI have been extensively metasomatized.

  18. Microstructures of Hibonite From an ALH A77307 (CO3.0) CAI: Evidence for Evaporative Loss of Calcium

    Science.gov (United States)

    Han, Jangmi; Brearley, Adrian J.; Keller, Lindsay P.

    2014-01-01

    Hibonite is a comparatively rare, primary phase found in some CAIs from different chondrite groups and is also common in Wark-Lovering rims [1]. Hibonite is predicted to be one of the earliest refractory phases to form by equilibrium condensation from a cooling gas of solar composition [2] and, therefore, can be a potential recorder of very early solar system processes. In this study, we describe the microstructures of hibonite from one CAI in ALH A77307 (CO3.0) using FIB/TEM techniques in order to reconstruct its formational history.

  19. Northwest Africa 10758: A New CV3 Chondrite Bearing a Giant CAI with Hibonite-Rich Wark-Lovering Rim

    Science.gov (United States)

    Ross, D. K.; Simon, J. I.; Zolensky, M.

    2017-01-01

    Northwest Africa (NWA) 10758 is a newly identified carbonaceous chondrite that is a Bali-like oxidized CV3. The large Ca-Al rich inclusion (CAI) in this sample is approx. 2.4 x 1.4 cm. The CAI is transitional in composition between type A and type B, with interior mineralogy dominated by melilite, plus less abundant spinel and Al-Ti rich diopside, and only very minor anorthite (Fig. 1A). This CAI is largely free of secondary alteration in the exposed section we examined, with almost no nepheline, sodalite or Ca-Fe silicates. The Wark-Lovering (WL) rim on this CAI is dominated by hibonite, with lower abundances of spinel and perovskite, and with hibonite locally overlain by melilite plus perovskite (as in Fig. 1B). Note that the example shown in 1B is exceptional. Around most of the CAI, hibonite + spinel + perovskite form the WL rim, without overlying melilite. The WL rim can be unusually thick, ranging from approx.20 microns up to approx. 150 microns. A well-developed, stratified accretionary rim infills embayments of the CAI, and thins over protuberances in the convoluted CAI surface.

  20. An ion microprobe study of CAIs from CO3 meteorites. [Abstract only

    Science.gov (United States)

    Russell, S. S.; Greenwood, R. C.; Fahey, A. J.; Huss, G. R.; Wasserburg, G. J.

    1994-01-01

    When attempting to interpret the history of Ca, Al-rich inclusions (CAIs) it is often difficult to distinguish between primary features inherited from the nebula and those produced during secondary processing on the parent body. We have undertaken a systematic study of CAIs from 10 CO chondrites, believed to represent a metamorphic sequence with the goal of distinguishing primary and secondary features. ALHA 77307 (3.0), Colony (3.0), Kainsaz (3.1), Felix (3.2), ALH 82101 (3.3), Ornans (3.3), Lance (3.4), ALHA 77003 (3.5), Warrenton (3.6), and Isna (3.7) were examined by Scanning Electron Microscopy (SEM) and optical microscopy. We have identified 141 CAIs within these samples, and studied in detail the petrology of 34 inclusions. The primary phases in the lower petrologic types are spinel, melilite, and hibonite. Perovskite, FeS, ilmenite, anorthite, kirschsteinite, and metallic Fe are present as minor phases. Melilite becomes less abundant in higher petrologic types and was not detected in chondrites of type 3.5 and above, confirming previous reports that this mineral easily breaks down during heating. Iron, an element that would not be expected to condense at high temperatures, has a lower abundance in spinel from low-petrologic-type meteorites than those of higher grade, and CaTiO3 is replaced by FeTiO3 in meteorites of higher petrologic type. The abundance of CAIs is similar in each meteorite. Eight inclusions have been analyzed by ion probe. The results are summarized. The results obtained to date show that CAIs in CO meteorites, like those from other meteorite classes, contain Mg* and that Mg in some inclusions has been redistributed.

  1. Gender Role, Gender Identity and Sexual Orientation in CAIS ("XY-Women") Compared With Subfertile and Infertile 46,XX Women.

    Science.gov (United States)

    Brunner, Franziska; Fliegner, Maike; Krupp, Kerstin; Rall, Katharina; Brucker, Sara; Richter-Appelt, Hertha

    2016-01-01

    The perception of gender development of individuals with complete androgen insensitivity syndrome (CAIS) as unambiguously female has recently been challenged in both qualitative data and case reports of male gender identity. The aim of the mixed-method study presented was to examine the self-perception of CAIS individuals regarding different aspects of gender and to identify commonalities and differences in comparison with subfertile and infertile XX-chromosomal women with diagnoses of Mayer-Rokitansky-Küster-Hauser syndrome (MRKHS) and polycystic ovary syndrome (PCOS). The study sample comprised 11 participants with CAIS, 49 with MRKHS, and 55 with PCOS. Gender identity was assessed by means of a multidimensional instrument, which showed significant differences between the CAIS group and the XX-chromosomal women. Other-than-female gender roles and neither-female-nor-male sexes/genders were reported only by individuals with CAIS. The percentage with a not exclusively androphile sexual orientation was unexceptionally high in the CAIS group compared to the prevalence in "normative" women and the clinical groups. The findings support the assumption made by Meyer-Bahlburg ( 2010 ) that gender outcome in people with CAIS is more variable than generally stated. Parents and professionals should thus be open to courses of gender development other than typically female in individuals with CAIS.

  2. Ion implantation control system

    International Nuclear Information System (INIS)

    Gault, R. B.; Keutzer, L. L.

    1985-01-01

    A control system is disclosed for an ion implantation system of the type in which the wafers to be implanted are mounted around the periphery of a disk which rotates and also moves in a radial direction relative to an ion beam to expose successive sections of each wafer to the radiation. The control system senses beam current which passes through one or more apertures in the disk and is collected by a Faraday cup. This current is integrated to obtain a measure of charge which is compared with a calculated value based upon the desired ion dosage and other parameters. The resultant controls the number of incremental steps the rotating disk moves radially to expose the adjacent sections of each wafer. This process is continued usually with two or more traverses until the entire surface of each wafer has been implanted with the proper ion dosage

  3. Calcium-aluminum-rich inclusions with fractionation and unidentified nuclear effects (FUN CAIs): II. Heterogeneities of magnesium isotopes and 26Al in the early Solar System inferred from in situ high-precision magnesium-isotope measurements

    Science.gov (United States)

    Park, Changkun; Nagashima, Kazuhide; Krot, Alexander N.; Huss, Gary R.; Davis, Andrew M.; Bizzarro, Martin

    2017-03-01

    Calcium-aluminum-rich inclusions with isotopic mass fractionation effects and unidentified nuclear isotopic anomalies (FUN CAIs) have been studied for more than 40 years, but their origins remain enigmatic. Here we report in situ high precision measurements of aluminum-magnesium isotope systematics of FUN CAIs by secondary ion mass spectrometry (SIMS). Individual minerals were analyzed in six FUN CAIs from the oxidized CV3 carbonaceous chondrites Axtell (compact Type A CAI Axtell 2271) and Allende (Type B CAIs C1 and EK1-4-1, and forsterite-bearing Type B CAIs BG82DH8, CG-14, and TE). Most of these CAIs show evidence for excess 26Mg due to the decay of 26Al. The inferred initial 26Al/27Al ratios [(26Al/27Al)0] and the initial magnesium isotopic compositions (δ26Mg0) calculated using an exponential law with an exponent β of 0.5128 are (3.1 ± 1.6) × 10-6 and 0.60 ± 0.10‰ (Axtell 2271), (3.7 ± 1.5) × 10-6 and -0.20 ± 0.05‰ (BG82DH8), (2.2 ± 1.1) × 10-6 and -0.18 ± 0.05‰ (C1), (2.3 ± 2.4) × 10-5 and -2.23 ± 0.37‰ (EK1-4-1), (1.5 ± 1.1) × 10-5 and -0.42 ± 0.08‰ (CG-14), and (5.3 ± 0.9) × 10-5 and -0.05 ± 0.08‰ (TE) with 2σ uncertainties. We infer that FUN CAIs recorded heterogeneities of magnesium isotopes and 26Al in the CAI-forming region(s). Comparison of 26Al-26Mg systematics, stable isotope (oxygen, magnesium, calcium, and titanium) and trace element studies of FUN and non-FUN igneous CAIs indicates that there is a continuum among these CAI types. Based on these observations and evaporation experiments on CAI-like melts, we propose a generic scenario for the origin of igneous (FUN and non-FUN) CAIs: (i) condensation of isotopically normal solids in an 16O-rich gas of approximately solar composition; (ii) formation of CAI precursors by aggregation of these solids together with variable abundances of isotopically anomalous grains-possible carriers of unidentified nuclear (UN) effects; and (iii) melt evaporation of these precursors

  4. The Cognitive Assessment Interview (CAI): development and validation of an empirically derived, brief interview-based measure of cognition.

    Science.gov (United States)

    Ventura, Joseph; Reise, Steven P; Keefe, Richard S E; Baade, Lyle E; Gold, James M; Green, Michael F; Kern, Robert S; Mesholam-Gately, Raquelle; Nuechterlein, Keith H; Seidman, Larry J; Bilder, Robert M

    2010-08-01

    Practical, reliable "real world" measures of cognition are needed to supplement neurocognitive performance data to evaluate possible efficacy of new drugs targeting cognitive deficits associated with schizophrenia. Because interview-based measures of cognition offer one possible approach, data from the MATRICS initiative (n=176) were used to examine the psychometric properties of the Schizophrenia Cognition Rating Scale (SCoRS) and the Clinical Global Impression of Cognition in Schizophrenia (CGI-CogS). We used classical test theory methods and item response theory to derive the 10-item Cognitive Assessment Interview (CAI) from the SCoRS and CGI-CogS ("parent instruments"). Sources of information for CAI ratings included the patient and an informant. Validity analyses examined the relationship between the CAI and objective measures of cognitive functioning, intermediate measures of cognition, and functional outcome. The rater's score from the newly derived CAI (10 items) correlate highly (r=.87) with those from the combined set of the SCoRS and CGI-CogS (41 items). Both the patient (r=.82) and the informant (r=.95) data were highly correlated with the rater's score. The CAI was modestly correlated with objectively measured neurocognition (r=-.32), functional capacity (r=-.44), and functional outcome (r=-.32), which was comparable to the parent instruments. The CAI allows for expert judgment in evaluating a patient's cognitive functioning and was modestly correlated with neurocognitive functioning, functional capacity, and functional outcome. The CAI is a brief, repeatable, and potentially valuable tool for rating cognition in schizophrenia patients who are participating in clinical trials. Copyright 2010 Elsevier B.V. All rights reserved.

  5. Exploring Chondrule and CAI Rims Using Micro- and Nano-Scale Petrological and Compositional Analysis

    Science.gov (United States)

    Cartwright, J. A.; Perez-Huerta, A.; Leitner, J.; Vollmer, C.

    2017-12-01

    As the major components within chondrites, chondrules (mm-sized droplets of quenched silicate melt) and calcium-aluminum-rich inclusions (CAI, refractory) represent the most abundant and the earliest materials that solidified from the solar nebula. However, the exact formation mechanisms of these clasts, and whether these processes are related, remains unconstrained, despite extensive petrological and compositional study. By taking advantage of recent advances in nano-scale tomographical techniques, we have undertaken a combined micro- and nano-scale study of CAI and chondrule rim morphologies, to investigate their formation mechanisms. The target lithologies for this research are Wark-Lovering rims (WLR), and fine-grained rims (FGR) around CAIs and chondrules respectively, present within many chondrites. The FGRs, which are up to 100 µm thick, are of particular interest as recent studies have identified presolar grains within them. These grains predate the formation of our Solar System, suggesting FGR formation under nebular conditions. By contrast, WLRs are 10-20 µm thick, made of different compositional layers, and likely formed by flash-heating shortly after CAI formation, thus recording nebular conditions. A detailed multi-scale study of these respective rims will enable us to better understand their formation histories and determine the potential for commonality between these two phases, despite reports of an observed formation age difference of up to 2-3 Myr. We are using a combination of complimentary techniques on our selected target areas: 1) Micro-scale characterization using standard microscopic and compositional techniques (SEM-EBSD, EMPA); 2) Nano-scale characterization of structures using transmission electron microscopy (TEM) and elemental, isotopic and tomographic analysis with NanoSIMS and atom probe tomography (APT). Preliminary nano-scale APT analysis of FGR morphologies within the Allende carbonaceous chondrite has successfully discerned

  6. Rancangan Perangkat Lunak Computer Assisted Instruction (CAI Untuk Ilmu Tajwid Berbasis Web

    Directory of Open Access Journals (Sweden)

    Fenny Purwani

    2015-08-01

    Full Text Available The development of information technology and science refer to the need of teching-learning concept and mechanism wich are based on information technology, undoubtedly. Regarding the development, it needs qualified human resources and flexible material changing and it should be appropriate with technology and science development. Additionaly, this combines between education based on religious and techology (IMTAK and IPTEK. Internet techology can be used as teaching tool which is known as Computer Assisted Intruction (CAI. CAI software might be one of media or tool in learnig tajwid and it can help people to learn Tajwid easier.

  7. A Braça da Rede, uma Técnica Caiçara de Medir

    Directory of Open Access Journals (Sweden)

    Gilberto Chieus Jr.

    2009-08-01

    Full Text Available Este artigo relata como os caiçaras da cidade de Ubatuba litoral norte paulista medem suas redes de pesca.Mas antes de estar analisando sua técnica de medir estaremos fazendo uma pequena abordagem da cultura caiçara e suas transformações. Em seguida mostraremos alguns momentos históricos da construção do metro. Depois como os caiçaras medem suas redes e o problema ocorrido no Brasil na implantação do sistema métrico decimal e a resistência de determinadas civilizações que se utiliza de outros padrões para realizar suas medidas, ignorando o atual sistema métrico, devidos o seu contexto cultural. Toda esta discussão está enfocada numa perspectiva histórica da Etnomatemática.

  8. Mandibular implant-supported overdentures: attachment systems, and number and locations of implants--Part I.

    Science.gov (United States)

    Warreth, Abdulhadi; Alkadhimi, Aslam Fadel; Sultan, Ahmed; Byrne, Caroline; Woods, Edel

    2015-01-01

    The use of dental implants in replacing missing teeth is an integral part of restorative dental treatment. Use of conventional complete dentures is associated with several problems such as lack of denture stability, support and retention. However, when mandibular complete dentures were used with two or more implants, an improvement in the patients' psychological and social well-being could be seen. There is general consensus that removable implant-supported overdentures (RISOs) with two implants should be considered as the first-choice standard of care for an edentulous mandible. This treatment option necessitates the use of attachment systems that connect the complete denture to the implant. Nevertheless, each attachment system has its inherent advantages and disadvantages, which should be considered when choosing a system. The first part of this article provides an overview on options available to restore the mandibular edentulous arch with dental implants. Different types of attachment systems, their features and drawbacks are also reviewed.

  9. CLINICAL CONSIDERATIONS OF DENTAL IMPLANT SYSTEM IN IMMEDIATE LOADING IMPLANT CASES

    Directory of Open Access Journals (Sweden)

    Carolina Damayanti Marpaung

    2015-06-01

    Full Text Available Immediate loading of dental implant has been researched intensively in the development of Branemark’s early concept of 2 stages implant placement. This was embarked from both patients and practiitioner’s convenience towards a simpler protocol and shorter time frame. Many recent researchers later found that micromotions derived from occlusal loading for a certain degree, instead of resulting a fibrous tissue encapsulation, can enhance the osseointegration process. Dental Implant system enhancement towards maximizing the primary stability held a key factor in Branemark’s concept development. Surgical protocol and implant design was found to give a significant contribution to the prognosis of immediate-loading implants.

  10. OXYGEN ISOTOPIC COMPOSITIONS OF THE ALLENDE TYPE C CAIs: EVIDENCE FOR ISOTOPIC EXCHANGE DURING NEBULAR MELTING AND ASTEROIDAL THERMAL METAMORPHISM

    Energy Technology Data Exchange (ETDEWEB)

    Krot, A N; Chaussidon, M; Yurimoto, H; Sakamoto, N; Nagashima, K; Hutcheon, I D; MacPherson, G J

    2008-02-21

    Based on the mineralogy and petrography, coarse-grained, igneous, anorthite-rich (Type C) calcium-aluminum-rich inclusions (CAIs) in the CV3 carbonaceous chondrite Allende have been recently divided into three groups: (i) CAIs with melilite and Al,Ti-diopside of massive and lacy textures (coarse grains with numerous rounded inclusions of anorthite) in a fine-grained anorthite groundmass (6-1-72, 100, 160), (ii) CAI CG5 with massive melilite, Al,Ti-diopside and anorthite, and (iii) CAIs associated with chondrule material: either containing chondrule fragments in their peripheries (ABC, TS26) or surrounded by chondrule-like, igneous rims (93) (Krot et al., 2007a,b). Here, we report in situ oxygen isotopic measurements of primary (melilite, spinel, Al,Ti-diopside, anorthite) and secondary (grossular, monticellite, forsterite) minerals in these CAIs. Spinel ({Delta}{sup 17}O = -25{per_thousand} to -20{per_thousand}), massive and lacy Al,Ti-diopside ({Delta}{sup 17}O = -20{per_thousand} to -5{per_thousand}) and fine-grained anorthite ({Delta}{sup 17}O = -15{per_thousand} to -2{per_thousand}) in 100, 160 and 6-1-72 are {sup 16}O-enriched relative spinel and coarse-grained Al,Ti-diopside and anorthite in ABC, 93 and TS26 ({Delta}{sup 17}O ranges from -20{per_thousand} to -15{per_thousand}, from -15{per_thousand} to -5{per_thousand}, and from -5{per_thousand} to 0{per_thousand}, respectively). In 6-1-72, massive and lacy Al,Ti-diopside grains are {sup 16}O-depleted ({Delta}{sup 17}O {approx} -13{per_thousand}) relative to spinel ({Delta}{sup 17}O = -23{per_thousand}). Melilite is the most {sup 16}O-depleted mineral in all Allende Type C CAIs. In CAI 100, melilite and secondary grossular, monticellite and forsterite (minerals replacing melilite) are similarly {sup 16}O-depleted, whereas grossular in CAI 160 is {sup 16}O-enriched ({Delta}{sup 17}O = -10{per_thousand} to -6{per_thousand}) relative to melilite ({Delta}{sup 17}O = -5{per_thousand} to -3{per_thousand}). We infer

  11. Multiple Nebular Gas Reservoirs Recorded by Oxygen Isotope Variation in a Spinel-rich CAI in CO3 MIL 090019

    Science.gov (United States)

    Simon, J. I.; Simon, S. B.; Nguyen, A. N.; Ross, D. K.; Messenger, S.

    2017-01-01

    We conducted NanoSIMS O-isotopic imaging of a primitive spinel-rich CAI spherule (27-2) from the MIL 090019 CO3 chondrite. Inclusions such as 27-2 are proposed to record inner nebula processes during an epoch of rapid solar nebula evolution. Mineralogical and textural analyses suggest that this CAI formed by high temperature reactions, partial melting, and condensation. This CAI exhibits radial O-isotopic heterogeneity among multiple occurrences of the same mineral, reflecting interactions with distinct nebular O-isotopic reservoirs.

  12. The enhancement of students’ mathematical representation in junior high school using cognitive apprenticeship instruction (CAI)

    Science.gov (United States)

    Yusepa, B. G. P.; Kusumah, Y. S.; Kartasasmita, B. G.

    2018-03-01

    This study aims to get an in-depth understanding of the enhancement of students’ mathematical representation. This study is experimental research with pretest-posttest control group design. The subject of this study is the students’ of the eighth grade from junior high schools in Bandung: high-level and middle-level. In each school, two parallel groups were chosen as a control group and an experimental group. The experimental group was given cognitive apprenticeship instruction (CAI) treatment while the control group was given conventional learning. The results show that the enhancement of students’ mathematical representation who obtained CAI treatment was better than the conventional one, viewed which can be observed from the overall, mathematical prior knowledge (MPK), and school level. It can be concluded that CAI can be used as a good alternative learning model to enhance students’ mathematical representation.

  13. Cranial implant design using augmented reality immersive system.

    Science.gov (United States)

    Ai, Zhuming; Evenhouse, Ray; Leigh, Jason; Charbel, Fady; Rasmussen, Mary

    2007-01-01

    Software tools that utilize haptics for sculpting precise fitting cranial implants are utilized in an augmented reality immersive system to create a virtual working environment for the modelers. The virtual environment is designed to mimic the traditional working environment as closely as possible, providing more functionality for the users. The implant design process uses patient CT data of a defective area. This volumetric data is displayed in an implant modeling tele-immersive augmented reality system where the modeler can build a patient specific implant that precisely fits the defect. To mimic the traditional sculpting workspace, the implant modeling augmented reality system includes stereo vision, viewer centered perspective, sense of touch, and collaboration. To achieve optimized performance, this system includes a dual-processor PC, fast volume rendering with three-dimensional texture mapping, the fast haptic rendering algorithm, and a multi-threading architecture. The system replaces the expensive and time consuming traditional sculpting steps such as physical sculpting, mold making, and defect stereolithography. This augmented reality system is part of a comprehensive tele-immersive system that includes a conference-room-sized system for tele-immersive small group consultation and an inexpensive, easily deployable networked desktop virtual reality system for surgical consultation, evaluation and collaboration. This system has been used to design patient-specific cranial implants with precise fit.

  14. CAIS/ACSI 2001: Beyond the Web: Technologies, Knowledge and People.

    Science.gov (United States)

    Canadian Journal of Information and Library Science, 2000

    2000-01-01

    Presents abstracts of papers presented at the 29th Annual Conference of the Canadian Association for Information Science (CAIS) held in Quebec on May 27-29, 2001. Topics include: professional development; librarian/library roles; information technology uses; virtual libraries; information seeking behavior; literacy; information retrieval;…

  15. CAI多媒體教學軟體之開發模式 Using an Instructional Design Model for Developing a Multimedia CAI Courseware

    Directory of Open Access Journals (Sweden)

    Hsin-Yih Shyu

    1995-09-01

    Full Text Available 無This article outlined a systematic instructional design model for developing a multimedia computer-aided instruction (CAI courseware. The model illustrated roles and tasks as two dimensions necessary in a CAI production teamwork. Four major components (Analysis, Design, Development, and Revise/Evaluation following by totally 25 steps are provided. Eight roles with each competent skills were identified. The model will be useful in serving as a framework for developing a mulrimedia CAI courseware for educators, instructional designers and CAI industry developers.

  16. Remote powering and data communication for implanted biomedical systems

    CERN Document Server

    Kilinc, Enver Gurhan; Maloberti, Franco

    2016-01-01

    This book describes new circuits and systems for implantable biomedical applications and explains the design of a batteryless, remotely-powered implantable micro-system, designed for long-term patient monitoring.  Following new trends in implantable biomedical applications, the authors demonstrate a system which is capable of efficient, remote powering and reliable data communication.  Novel architecture and design methodologies are used to transfer power with a low-power, optimized inductive link and data is transmitted by a reliable communication link.  Additionally, an electro-mechanical solution is presented for tracking and monitoring the implantable system, while the patient is mobile.  ·         Describes practical example of an implantable batteryless biomedical system; ·         Analyzes and compares various energy harvesting and power transfer methods; ·         Describes design of remote powering link and data communication of the implantable system, comparing differe...

  17. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  18. Implant Angle Monitor System of MC3-II

    International Nuclear Information System (INIS)

    Sato, Fumiaki; Sano, Makoto; Nakaoka, Hiroaki; Fujii, Yoshito; Kudo, Tetuya; Nakanishi, Makoto; Koike, Masazumi; Fujino, Yasushi

    2008-01-01

    Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.

  19. Cone-morse implant connection system significantly reduces bacterial leakage between implant and abutment: an in vitro study.

    Science.gov (United States)

    Baj, A; Bolzoni, A; Russillo, A; Lauritano, D; Palmieri, A; Cura, F; Silvestre, F J; Giannì, A B

    2017-01-01

    Osseointegrated implants are very popular dental treatments today in the world. In osseointegrated implants, the occlusal forces are transmitted from prosthesis through an abutment to a dental implant. The abutment is connected to the implant by mean of a screw. A screw is the most used mean for connecting an implant to an abutment. Frequently the screws break and are lost. There is an alternative to screw retained abutment systems: the cone-morse connection (CMC). The CMC, thanks to the absence of the abutment screw, guarantees no micro-gaps, no micro-movements, and a reduction of bacterial leakage between implant and abutment. As P. gingivalis and T. forsythia penetration might have clinical relevance, it was the purpose of this investigation to evaluate molecular leakage of these two bacteria in a new CMC implants systems (Leone Spa®, Florence, Italy). To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Four cone-morse Leone implants (Leone® Spa, Florence, Italy) were immerged in a bacterial culture for 24 h and bacteria amount was then measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 3% for P. gingivalis and 4% for T. forsythia. Cone-morse connection implant system has very low bacterial leakage percentage and is similar to one-piece implants.

  20. Image-guided navigation system for placing dental implants.

    Science.gov (United States)

    Casap, Nardy; Wexler, Alon; Lustmann, Joshua

    2004-10-01

    Navigation-guided surgery has recently been introduced into various surgical disciplines, including oral and maxillofacial surgery. Since the advent of dental implants, dental computed tomography (CT) scans have been used as a diagnostic tool for preoperative planning, but not as part of the surgical phase. This article explains the principles of computer-assisted surgery and describes the use of a computer-guided navigation system in dental implantology. The system uses preoperative dental CT scans for planning and as an integral part of the surgical procedure. This system allows continuous intraoperative coordination of the implantation phase with the preoperative plan, optimizing the accuracy of implant surgery. Deviations from the planned location of the implants are minimal. Several cases are discussed.

  1. Consumption of fa cai Nostoc soup: a potential for BMAA exposure from Nostoc cyanobacteria in China?

    Science.gov (United States)

    Roney, Britton R; Renhui, Li; Banack, Sandra Anne; Murch, Susan; Honegger, Rosmarie; Cox, Paul Alan

    2009-01-01

    Grown in arid regions of western China the cyanobacterium Nostoc flagelliforme--called fa cai in Mandarin and fat choy in Cantonese--is wild-harvested and used to make soup consumed during New Year's celebrations. High prices, up to $125 USD/kg, led to overharvesting in Inner Mongolia, Ningxia, Gansu, Qinghai, and Xinjiang. Degradation of arid ecosystems, desertification, and conflicts between Nostoc harvesters and Mongol herdsmen concerned the Chinese environmental authorities, leading to a government ban of Nostoc commerce. This ban stimulated increased marketing of a substitute made from starch. We analysed samples purchased throughout China as well as in Chinese markets in the United States and the United Kingdom. Some were counterfeits consisting of dyed starch noodles. A few samples from California contained Nostoc flagelliforme but were adulterated with starch noodles. Other samples, including those from the United Kingdom, consisted of pure Nostoc flagelliforme. A recent survey of markets in Cheng Du showed no real Nostoc flagelliforme to be marketed. Real and artificial fa cai differ in the presence of beta-N-methylamino-L-alanine (BMAA). Given its status as a high-priced luxury food, the government ban on collection and marketing, and the replacement of real fa cai with starch substitutes consumed only on special occasions, it is anticipated that dietary exposure to BMAA from fa cai will be reduced in the future in China.

  2. Hunting and use of terrestrial fauna used by Caiçaras from the Atlantic Forest coast (Brazil

    Directory of Open Access Journals (Sweden)

    Alves Rômulo RN

    2009-11-01

    Full Text Available Abstract Background The Brazilian Atlantic Forest is considered one of the hotspots for conservation, comprising remnants of rain forest along the eastern Brazilian coast. Its native inhabitants in the Southeastern coast include the Caiçaras (descendants from Amerindians and European colonizers, with a deep knowledge on the natural resources used for their livelihood. Methods We studied the use of the terrestrial fauna in three Caiçara communities, through open-ended interviews with 116 native residents. Data were checked through systematic observations and collection of zoological material. Results The dependence on the terrestrial fauna by Caiçaras is especially for food and medicine. The main species used are Didelphis spp., Dasyprocta azarae, Dasypus novemcinctus, and small birds (several species of Turdidae. Contrasting with a high dependency on terrestrial fauna resources by native Amazonians, the Caiçaras do not show a constant dependency on these resources. Nevertheless, the occasional hunting of native animals represents a complimentary source of animal protein. Conclusion Indigenous or local knowledge on native resources is important in order to promote local development in a sustainable way, and can help to conserve biodiversity, particularly if the resource is sporadically used and not commercially exploited.

  3. Patient satisfaction with maxillary 3-implant overdentures using different attachment systems opposing mandibular 2-implant overdentures.

    Science.gov (United States)

    Al-Zubeidi, Mohammed I; Alsabeeha, Nabeel H M; Thomson, W Murray; Payne, Alan G T

    2012-05-01

    Patient-based outcomes with maxillary overdentures on a minimum number of implants, opposing mandibular 2-implant overdentures are not evident in the literature. To evaluate patient's satisfaction with maxillary 3-implant overdentures, opposing mandibular 2-implant overdentures, using two different attachment systems over the first 2 years of service. Forty participants wearing mandibular 2-implant overdentures for 3 years were randomly allocated to one of two similar implant system groups to receive maxillary 3-implant overdentures. Twenty participants were allocated to splinted and unsplinted attachment system treatment groups for each system. Patient satisfaction with pre-treatment complete maxillary dentures, with maxillary 3-implant overdentures at baseline and annually for 2 years, was measured using visual analogue scale questionnaires and the oral health impact profiles. Palatal coverage of the maxillary overdentures was reduced at the first annual recall. Data showed significant improvement in pain reduction, comfort, stability, and function variables of the visual analogue scale after treatment. Analysis by prosthodontic design using visual analogue scale showed no significant difference. The total oral health impact profile-14 scores after treatment for all participants, regardless of prosthodontic design, were significantly lower (more satisfied). The overall oral health impact profile-20E score at baseline was significantly higher (more satisfied) compared with pre-treatment conventional maxillary dentures. No significant changes were observed in the first or second years compared with baseline results. Twenty-two participants (84.6%) preferred reduced palatal coverage, regardless of prosthodontic design, after 1 year. Twenty participants (76.9%) still preferred reduced palatal coverage at the end of the second year. The provision of maxillary 3-implant overdentures to oppose mandibular 2-implant overdentures significantly improve levels of patient

  4. Intra-arterial port implantation for intra-arterial chemotherapy : comparison between PIPS(Percutaneously Implantable Port System) and port system

    International Nuclear Information System (INIS)

    Yoon, Sang Jin; Shim, Hyung Jin; Jung, Hun Young; Choi, Yong Ho; Kim, Yang Soo; Song, In Sup; Kwak, Byung Kook

    1999-01-01

    To compare the techniques and complications of intra-arterial port implantation for intra-arterial chemotherapy between PIPS and the port system. For intra-arterial port implantation, 27 cases in 27 patients were retrospectively evaluated using PIPS(PIPS-200, William Cook Europe, Denmark) while for 21 cases in 19 patients a pediatric venous port system(Port-A-Cath, 5.8F, SIMS Deltec, U. S. A.) was used. All intra-arterial port implantation was performed percuteneously in an angiographic ward. Hepatocellular carcinoma was diagnosed in 18 patients and hepatic metastasis in 16. Peripheral cholangiocarcinoma, and pancreatic gastric, ovarian, renal cell and colon carcinoma were included. We compared the techniques and complications between PIPS and the port system. The follow up period ranged from 23 to 494(mean, 163) days in PIPS and from 12 to 431(mean, 150) days in the port system. In all cases, intra-arterial port implantations were technically successful. Port catheter tips were located in the common hepatic artery(n=8), proper hepatic artery(n=7), right hepatic artery(n=5), gastroduodenal artery(n=2), left hepatic artery(n=1), pancreaticoduodenal artery(n=1), inferior mesenteric artery(n=1), lumbar artery(n=1), and renal artery(n=1) in PIPS, and in the proper hepatic artery(n=6), gastroduodenal artery(n=6), common hepatic artery(n=3), right hepatic artery(n=4), inferior mesenteric artery(n=1), and internal iliac artery(n=1) in the port system. Port chambers were buried in infrainguinal subcutaneous tissue. Using PIPS, complications developed in seven cases(25.9%) and of these, four (57.1%) were catheter or chamber related. In the port system, catheter or chamber related complications developed in four cases(19.0%). Because PIPS and the port system have relative merits and demetrits, successful intra-arterial port implantation is possible if equipment is properly selected

  5. Attachment systems for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Kim, Ha-Young; Lee, Jeong-Yol; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review was to address treatment outcome according to attachment systems for mandibular implant overdentures in terms of implant survival rate, prosthetic maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted using PubMed and hand searching of relevant journals considering inclusion and exclusion criteria. Clinical trial studies on mandibular implant overdentures until August, 2010 were selected if more than one type of overdenture attachment was reported. Twenty four studies from 1098 studies were finally included and the data on implant survival rate, prosthetic maintenance and complications, patient satisfaction were analyzed relative to attachment systems. RESULTS Four studies presented implant survival rates (95.8 - 97.5% for bar, 96.2 - 100% for ball, 91.7% for magnet) according to attachment system. Ten other studies presented an implant survival rate ranging from 93.3% to 100% without respect to the attachment groups. Common prosthetic maintenance and complications were replacement of an assay for magnet attachments, and activation of a matrix or clip for ball or bar attachments. Prosthetic maintenance and complications most commonly occurred in the magnet groups. Conflicting findings were found on the rate of prosthetic maintenance and complications comparing ball and bar attachments. Most studies showed no significant differences in patient satisfaction depending upon attachment systems. CONCLUSION The implant survival rate of mandibular overdentures seemed to be high regardless attachment systems. The prosthetic maintenance and complications may be influenced by attachment systems. However patient satisfaction may be independent of the attachment system. PMID:23236571

  6. CAD/CAM/CAI Application for High-Precision Machining of Internal Combustion Engine Pistons

    Directory of Open Access Journals (Sweden)

    V. V. Postnov

    2014-07-01

    Full Text Available CAD/CAM/CAI application solutions for internal combustion engine pistons machining was analyzed. Low-volume technology of internal combustion engine pistons production was proposed. Fixture for CNC turning center was designed.

  7. Systemic alendronate treatment improves fixation of press-fit implants: a canine study using nonloaded implants

    DEFF Research Database (Denmark)

    Jensen, Thomas B; Bechtold, Joan E; Chen, Xinqian

    2007-01-01

    of alendronate treatment. Bone ongrowth (bone in contact with implant surface) was estimated using the linear intercept technique and shear strength was calculated as the slope on a load-displacement curve. For the press fit implants, alendronate treatment significantly increased bone ongrowth from 24% to 29...... early implant stability is an important predictor of longevity, systemic alendronate treatment could be an important clinical tool to positively influence the early stages of implant incorporation. Udgivelsesdato: 2007-Jun...

  8. Wireless energizing system for an automated implantable sensor

    Energy Technology Data Exchange (ETDEWEB)

    Swain, Biswaranjan; Nayak, Praveen P.; Kar, Durga P.; Bhuyan, Satyanarayan; Mishra, Laxmi P. [Department of Electronics and Instrumentation Engineering, Siksha ‘O’ Anusandhan University, Bhubaneswar 751030 (India)

    2016-07-15

    The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.

  9. Wireless energizing system for an automated implantable sensor

    International Nuclear Information System (INIS)

    Swain, Biswaranjan; Nayak, Praveen P.; Kar, Durga P.; Bhuyan, Satyanarayan; Mishra, Laxmi P.

    2016-01-01

    The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.

  10. Wireless energizing system for an automated implantable sensor.

    Science.gov (United States)

    Swain, Biswaranjan; Nayak, Praveen P; Kar, Durga P; Bhuyan, Satyanarayan; Mishra, Laxmi P

    2016-07-01

    The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.

  11. The Biolink Implantable Telemetry System

    Science.gov (United States)

    Betancourt-Zamora, Rafael J.

    1999-01-01

    Most biotelemetry applications deal with the moderated data rates of biological signals. Few people have studied the problem of transcutaneous data transmission at the rates required by NASA's Life Sciences-Advanced BioTelemetry System (LS-ABTS). Implanted telemetry eliminate the problems associated with wire breaking the skin, and permits experiments with awake and unrestrained subjects. Our goal is to build a low-power 174-216MHz Radio Frequency (RF) transmitter suitable for short range biosensor and implantable use. The BioLink Implantable Telemetry System (BITS) is composed of three major units: an Analog Data Module (ADM), a Telemetry Transmitter Module (TTM), and a Command Receiver Module (CRM). BioLink incorporates novel low-power techniques to implement a monolithic digital RF transmitter operating at 100kbps, using quadrature phase shift keying (QPSK) modulation in the 174-216MHz ISM band. As the ADM will be specific for each application, we focused on solving the problems associated with a monolithic implementation of the TTM and CRM, and this is the emphasis of this report. A system architecture based on a Frequency-Locked Loop (FLL) Frequency Synthesizer is presented, and a novel differential frequency that eliminates the need for a frequency divider is also shown. A self sizing phase modulation scheme suitable for low power implementation was also developed. A full system-level simulation of the FLL was performed and loop filter parameters were determined. The implantable antenna has been designed, simulated and constructed. An implant package compatible with the ABTS requirements is also being proposed. Extensive work performed at 200MHz in 0.5um complementary metal oxide semiconductors (CMOS) showed the feasibility of integrating the RF transmitter circuits in a single chip. The Hajimiri phase noise model was used to optimize the Voltage Controlled Oscillator (VCO) for minimum power consumption. Two test chips were fabricated in a 0.5pm, 3V CMOS

  12. Changes in flavour and microbial diversity during natural fermentation of suan-cai, a traditional food made in Northeast China.

    Science.gov (United States)

    Wu, Rina; Yu, Meiling; Liu, Xiaoyu; Meng, Lingshuai; Wang, Qianqian; Xue, Yating; Wu, Junrui; Yue, Xiqing

    2015-10-15

    We measured changes in the main physical and chemical properties, flavour compounds and microbial diversity in suan-cai during natural fermentation. The results showed that the pH and concentration of soluble protein initially decreased but were then maintained at a stable level; the concentration of nitrite increased in the initial fermentation stage and after reaching a peak it decreased significantly to a low level by the end of fermentation. Suan-cai was rich in 17 free amino acids. All of the free amino acids increased in concentration to different degrees, except histidine. Total free amino acids reached their highest levels in the mid-fermentation stage. The 17 volatile flavour components identified at the start of fermentation increased to 57 by the mid-fermentation stage; esters and aldehydes were in the greatest diversity and abundance, contributing most to the aroma of suan-cai. Bacteria were more abundant and diverse than fungi in suan-cai; 14 bacterial species were identified from the genera Leuconostoc, Bacillus, Pseudomonas and Lactobacillus. The predominant fungal species identified were Debaryomyces hansenii, Candida tropicalis and Penicillium expansum. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Calcium-aluminum-rich inclusions with fractionation and unknown nuclear effects (FUN CAIs)

    DEFF Research Database (Denmark)

    Krot, Alexander N.; Nagashima, Kazuhide; Wasserburg, Gerald J.

    2014-01-01

    We present a detailed characterization of the mineralogy, petrology, and oxygen isotopic compositions of twelve FUN CAIs, including C1 and EK1-4-1 from Allende (CV), that were previously shown to have large isotopic fractionation patterns for magnesium and oxygen, and large isotopic anomalies...

  14. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    Background: Procedure‑related and patient‑related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty‑one patients were included in the study, in which a total of 110 dental ...

  15. Analytical and experimental position stability of the abutment in different dental implant systems with a conical implant?abutment connection

    OpenAIRE

    Semper-Hogg, Wiebke; Kraft, Silvan; Stiller, Sebastian; Mehrhof, Juergen; Nelson, Katja

    2012-01-01

    Objectives Position stability of the abutment should be investigated in four implant systems with a conical implant?abutment connection. Materials and methods Previously developed formulas and an established experimental setup were used to determine the position stability of the abutment in the four implant systems with a conical implant?abutment connection and different positional index designs: The theoretical rotational freedom was calculated by using the dimensions of one randomly selecte...

  16. Numerical investigation of CAI Combustion in the Opposed- Piston Engine with Direct and Indirect Water Injection

    Science.gov (United States)

    Pyszczek, R.; Mazuro, P.; Teodorczyk, A.

    2016-09-01

    This paper is focused on the CAI combustion control in a turbocharged 2-stroke Opposed-Piston (OP) engine. The barrel type OP engine arrangement is of particular interest for the authors because of its robust design, high mechanical efficiency and relatively easy incorporation of a Variable Compression Ratio (VCR). The other advantage of such design is that combustion chamber is formed between two moving pistons - there is no additional cylinder head to be cooled which directly results in an increased thermal efficiency. Furthermore, engine operation in a Controlled Auto-Ignition (CAI) mode at high compression ratios (CR) raises a possibility of reaching even higher efficiencies and very low emissions. In order to control CAI combustion such measures as VCR and water injection were considered for indirect ignition timing control. Numerical simulations of the scavenging and combustion processes were performed with the 3D CFD multipurpose AVL Fire solver. Numerous cases were calculated with different engine compression ratios and different amounts of directly and indirectly injected water. The influence of the VCR and water injection on the ignition timing and engine performance was determined and their application in the real engine was discussed.

  17. Implantable power generation system utilizing muscle contractions excited by electrical stimulation.

    Science.gov (United States)

    Sahara, Genta; Hijikata, Wataru; Tomioka, Kota; Shinshi, Tadahiko

    2016-06-01

    An implantable power generation system driven by muscle contractions for supplying power to active implantable medical devices, such as pacemakers and neurostimulators, is proposed. In this system, a muscle is intentionally contracted by an electrical stimulation in accordance with the demands of the active implantable medical device for electrical power. The proposed system, which comprises a small electromagnetic induction generator, electrodes with an electrical circuit for stimulation and a transmission device to convert the linear motion of the muscle contractions into rotational motion for the magneto rotor, generates electrical energy. In an ex vivo demonstration using the gastrocnemius muscle of a toad, which was 28 mm in length and weighed 1.3 g, the electrical energy generated by the prototype exceeded the energy consumed for electrical stimulation, with the net power being 111 µW. It was demonstrated that the proposed implantable power generation system has the potential to replace implantable batteries for active implantable medical devices. © IMechE 2016.

  18. Sistema de fabrico rápido de implantes ortopédicos Rapid manufacturing system of orthopedics implants

    Directory of Open Access Journals (Sweden)

    Carlos Relvas

    2009-06-01

    /CAM system. After sterilization, the implant is able to be placed on the patient. The concept was developed using low cost technology and commercially available. The system has been tested in an in vivo hip arthroplasty performed on a sheep. The time increase of surgery was 80 minutes being 40 minutes the time of implant manufacturing. The system developed has been tested and the goals defined of the study achieved enabling the rapid manufacture of an implant in a time period compatible with the surgery time.

  19. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  20. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad; Ouda, Mahmoud H.; Marnat, Loic; Shamim, Atif; Salama, Khaled N.

    2013-01-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  1. [Comparative evaluation of two kinds of micro-implant system with different size].

    Science.gov (United States)

    Wang, Zhen-Dong; Li, Qing-Yi; Wang, Lin; Gu, Yong-Jia

    2009-04-01

    To offer some reference for micro-implant's development and population by analyzing clinical application of two kinds of micro-implant systems. 38 patients treated with MIA (micro-implant anchorage) and 28 patients treated with SDIA (self-driven titanium implant for orthodontic anchorage) were included. Analyzing the rate of lost implants, the gum's reactivity and the efficiency of moving teeth summarized the excellences and shortcomings of two systems. 1) Six of MIA implants fell off after being inserted. Seven of SDIA implants lost when they had been implanted for a month. But they were stable after being inserted again. 2) The gum around 12 SDIA implants got inflammation symptom, but the gum around MIA implants was normal. 3) Both MIA implants and SDIA implants could move teeth effectively and persistently when they were stable. When we apply micro-implant in clinic, we should prevent it from closing roots of teeth and choose the small tip micro-implant. The embedded position should be in area of attachment gum. At the same time, the areas around the tip of micro-implant should be keeping clean.

  2. Clinical application of single-tooth replacement with ankylos implant system

    International Nuclear Information System (INIS)

    Yang Xu; Liu Xue; Zhang Heng; Deng Yan; Guo Zhaozhong; Zhang Yufeng

    2011-01-01

    Objective: To evaluate the clinical effects of Ankylos implant system to restore the loss of single-tooth. Methods: 90 cases with loss of single-tooth were selected and treated with routinely two-stage surgery. When the patients presented with deficient alveolar ridge, guided bone regeneration (GBR), osteotome sinus floor elevation, lateral antrostomy surgery with simultaneous placement of implant were applied. They were restored with platinum ceramic crown. All the implants were followed up, and the records were kept about stability of the implant and abutment, the status of surrounding soft tissue, sealability of implant abutment junction and the marginal bone lossing through X-ray checking,and satisfaction of the patients to mastication and aspect of the restorations. The follow-up time was 1-2.5 years. Results: Among the cases,one case had peri-implant inflammation, and one case had porcelain dropped. No loosening occurred in the other implants and abuments. Implant abutment junction was sealed well. The marginal bone loss 1 year after final restoration was less than 1 mm. Soft tissue surrounding implants was healthy. The satisfaction rate was 98.9% (89/90). According to standard of implant success, 88 cases were successful, the 2.5-year cumulative success rate was 97.8%, 2 cases failed, and the failure rate was 2.2 %. Conclusion: A satisfactory treatment effects could be gotten by using Ankylos implant system to restore the loss of single-tooth. (authors)

  3. CO-Bridged H-Cluster Intermediates in the Catalytic Mechanism of [FeFe]-Hydrogenase CaI.

    Science.gov (United States)

    Ratzloff, Michael W; Artz, Jacob H; Mulder, David W; Collins, Reuben T; Furtak, Thomas E; King, Paul W

    2018-06-20

    The [FeFe]-hydrogenases ([FeFe] H 2 ases) catalyze reversible H 2 activation at the H-cluster, which is composed of a [4Fe-4S] H subsite linked by a cysteine thiolate to a bridged, organometallic [2Fe-2S] ([2Fe] H ) subsite. Profoundly different geometric models of the H-cluster redox states that orchestrate the electron/proton transfer steps of H 2 bond activation have been proposed. We have examined this question in the [FeFe] H 2 ase I from Clostridium acetobutylicum (CaI) by Fourier-transform infrared (FTIR) spectroscopy with temperature annealing and H/D isotope exchange to identify the relevant redox states and define catalytic transitions. One-electron reduction of H ox led to formation of H red H + ([4Fe-4S] H 2+ -Fe I -Fe I ) and H red ' ([4Fe-4S] H 1+ -Fe II -Fe I ), with both states characterized by low frequency μ-CO IR modes consistent with a fully bridged [2Fe] H . Similar μ-CO IR modes were also identified for H red H + of the [FeFe] H 2 ase from Chlamydomonas reinhardtii (CrHydA1). The CaI proton-transfer variant C298S showed enrichment of an H/D isotope-sensitive μ-CO mode, a component of the hydride bound H-cluster IR signal, H hyd . Equilibrating CaI with increasing amounts of NaDT, and probed at cryogenic temperatures, showed H red H + was converted to H hyd . Over an increasing temperature range from 10 to 260 K catalytic turnover led to loss of H hyd and appearance of H ox , consistent with enzymatic turnover and H 2 formation. The results show for CaI that the μ-CO of [2Fe] H remains bridging for all of the "H red " states and that H red H + is on pathway to H hyd and H 2 evolution in the catalytic mechanism. These results provide a blueprint for designing small molecule catalytic analogs.

  4. Numerical Investigation Into Effect of Fuel Injection Timing on CAI/HCCI Combustion in a Four-Stroke GDI Engine

    Science.gov (United States)

    Cao, Li; Zhao, Hua; Jiang, Xi; Kalian, Navin

    2006-02-01

    The Controlled Auto-Ignition (CAI) combustion, also known as Homogeneous Charge Compression Ignition (HCCI), was achieved by trapping residuals with early exhaust valve closure in conjunction with direct injection. Multi-cycle 3D engine simulations have been carried out for parametric study on four different injection timings in order to better understand the effects of injection timings on in-cylinder mixing and CAI combustion. The full engine cycle simulation including complete gas exchange and combustion processes was carried out over several cycles in order to obtain the stable cycle for analysis. The combustion models used in the present study are the Shell auto-ignition model and the characteristic-time combustion model, which were modified to take the high level of EGR into consideration. A liquid sheet breakup spray model was used for the droplet breakup processes. The analyses show that the injection timing plays an important role in affecting the in-cylinder air/fuel mixing and mixture temperature, which in turn affects the CAI combustion and engine performance.

  5. Retrospective study investigating the clinical success of two provisional implant systems

    OpenAIRE

    Hotz, Nadine

    2011-01-01

    The use of dental implants allows a reliable stabilisation of prosthesis. Usually, definitive implants can´t be used for fixation of prosthesis during their healing period. Therefore, in many cases it is not possible to follow the demand of patients of an immediate loading of definitive implants to avoid a unfixed dental prosthesis. This is one domain of provisional dental implants. The present study of two provisional implant systems approves the benefit of provisional implants during...

  6. Friction wear and dissolution of orthopedic implant systems

    International Nuclear Information System (INIS)

    Ektessabi, A.M.; Shikine, S.; Hamdi, M.; Kitamura, N.; Rokkum, M.; Johansson, C.

    2000-01-01

    Bio-medical implants release metallic elements during the long periods of time while inserted in the human body. The chemical interactions between the tissues and surface of the implants, and the mechanical friction of implants cause the release of metals into the human tissues. In this study we investigated the distribution and the chemical-state of the metallic elements in the tissues around a failed implant system using PIXE (proton induced x-ray emission) and SR-XRF (synchrotron radiation x-ray fluorescence) spectroscopies. The specimens were from the causes of patients with diagnosed arthritis. The implant consisted of a stem and a metal backing made of Ti-6Al-4V, an implant head made of stainless steel, and a polyethylene (PE) cup. Both the stem and the metal backing had a plasma-sprayed HAp surface coating. Distribution and concentration of dissolved elements in tissues surrounding implants were examined and quantified using PIXE analysis. Similar specimen from the same case was further investigated using SR-XRF analysis. Chemical-states of the dissolved elements were also studied by XAFS (x-ray absorption fine structure) analysis. From results of these measurements, it is confirmed that the tissues surrounding implants contained metallic elements such as Fe, Cr, Ni, and Ti. These elements are originated from the implant. Furthermore, it was made clear that the chemical-state of Fe had changed as a consequence of dissolution of Fe in the organic tissues. (author)

  7. Systemic conditions and treatments as risk for therapy with dental implants

    International Nuclear Information System (INIS)

    Arguedas Vega, Natalia; Alfaro Mayorga, Erika

    2013-01-01

    The possible risks for osseointegration are described in patients with specific systemic conditions, medical treatment such as radiation, cardiovascular diseases, HIV and smoking habit. The principal complications for osseointegration of diseases and systemic treatments are exposed. The review and search of the available literature are realized in databases. The scientific literature obtained from human studies has reported the survival of patients with dental implants. The implants are placed in patients with at least one of the conditions studied. The risks of the surgical procedures required for the placement of implants are analyzed in systemically compromised patients. Comparisons of patients with and without systemic conditions in controlled form have remained without analyzing. The level of evidence of absolute and relative contraindications has been low for the therapy with implants in patients with systemic diseases. The revised information is detailed according the systemic conditions, and each of them are evaluated separately [es

  8. Conhecimento e uso de plantas em uma comunidade caiçara do litoral sul do Estado do Rio de Janeiro, Brasil Knowledge and use of plants in a Caiçara community located on the southern coast of Rio de Janeiro State, Brazil

    Directory of Open Access Journals (Sweden)

    Rodrigo Borges

    2009-09-01

    Full Text Available A Área de Proteção Ambiental de Cairuçu (APA localiza-se no município de Paraty, RJ. É uma unidade de conservação de uso sustentável e dispõe-se a proteger o ambiente natural e as comunidades caiçaras da região. O objetivo deste estudo foi realizar um inventário etnobotânico das plantas conhecidas e utilizadas pela comunidade caiçara que habita a praia de Martim de Sá. Moram no local 30 pessoas das quais 10 foram entrevistadas. As informações etnobotânicas foram obtidas através da observação participante e entrevistas semi-estruturadas. O material botânico coletado foi depositado no Herbário do Instituto de Pesquisas Jardim Botânico do Rio de Janeiro (RB. Foram identificadas 76 espécies pertencentes a 59 gêneros e 30 famílias botânicas consideradas úteis pelos caiçaras. As três espécies mais citadas foram: Sloanea obtusifolia (Sapopema, Scherolobium denudatum (Ingá-ferro e Balizia pedicelaris (Timbuíba. Utilizou-se o Índice de Shannon (H' = 1,81 - base 10 para a análise da diversidade de espécies. O registro sobre o uso dos recursos vegetais na comunidade estudada fornece informações que podem ser utilizadas para programas de conservação baseados no conhecimento local do ambiente.The Cairuçu Environmental Protection Area (APA was created to help assure the protection of the natural environment and its sustainable use by the caiçara communities in the region. This work presents an ethnobotanical inventory of the plants known and used by the caiçara community living on Martim de Sá beach in Paraty municipality, RJ. Thirty people live in the locality and ten of them were interviewed. Ethnobotanical information was obtained through participatory observations and semi-structured interviews with the local residents. All botanical material collected was deposited in the herbarium of the Instituto de Pesquisas Jardim Botânico do Rio de Janeiro (RB. A total of 76 species belonging to 59 genera and 30

  9. Therapeutic interaction of systemically-administered mesenchymal stem cells with peri-implant mucosa.

    Directory of Open Access Journals (Sweden)

    Ryosuke Kondo

    Full Text Available OBJECTIVES: The objective of this study was to investigate the effect of systemically transplanted mesenchymal stem cells (MSCs on the peri-implant epithelial sealing around dental implants. MATERIALS AND METHODS: MSCs were isolated from bone marrow of donor rats and expanded in culture. After recipient rats received experimental titanium dental implants in the bone sockets after extraction of maxillary right first molars, donor rat MSCs were intravenously transplanted into the recipient rats. RESULTS: The injected MSCs were found in the oral mucosa surrounding the dental implants at 24 hours post-transplantation. MSC transplantation accelerated the formation of the peri-implant epithelium (PIE-mediated mucosa sealing around the implants at an early stage after implantation. Subsequently, enhanced deposition of laminin-332 was found along the PIE-implant interface at 4 weeks after the replacement. We also observed enhanced attachment and proliferation of oral mucous epithelial cells. CONCLUSION: Systemically transplanted MSCs might play a critical role in reinforcing the epithelial sealing around dental implants.

  10. CaI and SrI molecules for iodine determination by high-resolution continuum source graphite furnace molecular absorption spectrometry: Greener molecules for practical application.

    Science.gov (United States)

    Zanatta, Melina Borges Teixeira; Nakadi, Flávio Venâncio; da Veiga, Márcia Andreia Mesquita Silva

    2018-03-01

    A new method to determine iodine in drug samples by high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS) has been developed. The method measures the molecular absorption of a diatomic molecule, CaI or SrI (less toxic molecule-forming reagents), at 638.904 or 677.692nm, respectively, and uses a mixture containing 5μg of Pd and 0.5μg of Mg as chemical modifier. The method employs pyrolysis temperatures of 1000 and 800°C and vaporization temperatures of 2300 and 2400°C for CaI and SrI, respectively. The optimized amounts of Ca and Sr as molecule-forming reagents are 100 and 150µg, respectively. On the basis of interference studies, even small chlorine concentrations reduce CaI and SrI absorbance significantly. The developed method was used to analyze different commercial drug samples, namely thyroid hormone pills with three different iodine amounts (15.88, 31.77, and 47.66µg) and one liquid drug with 1% m v -1 active iodine in their compositions. The results agreed with the values informed by the manufacturers (95% confidence level) regardless of whether CaI or SrI was determined. Therefore, the developed method is useful for iodine determination on the basis of CaI or SrI molecular absorption. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. The Computer in a Programmable Implantable Medication System (PIMS)

    OpenAIRE

    Sanders, K. H.; Radford, W. E.

    1982-01-01

    The Programmable Implantable Medication System (PIMS) developed at APL can be used in the treatment of diabetes, reproductive hormone dysfunction, hypertension, cancer, chronic pain, thrombosis, and the delivery of growth hormone. The Implantable Programmable Infusion Pump (IPIP) is the implanted element of PIMS. Under control of a microprocessor, the IPIP administers medication and stores data pertaining to its operation. An external unit can read out the stored data, as well as program the ...

  12. Effects of implant system, impression technique, and impression material on accuracy of the working cast.

    Science.gov (United States)

    Wegner, Kerstin; Weskott, Katharina; Zenginel, Martha; Rehmann, Peter; Wöstmann, Bernd

    2013-01-01

    This in vitro study aimed to identify the effects of the implant system, impression technique, and impression material on the transfer accuracy of implant impressions. The null hypothesis tested was that, in vitro and within the parameters of the experiment, the spatial relationship of a working cast to the placement of implants is not related to (1) the implant system, (2) the impression technique, or (3) the impression material. A steel maxilla was used as a reference model. Six implants of two different implant systems (Standard Plus, Straumann; Semados, Bego) were fixed in the reference model. The target variables were: three-dimensional (3D) shift in all directions, implant axis direction, and rotation. The target variables were assessed using a 3D coordinate measuring machine, and the respective deviations of the plaster models from the nominal values of the reference model were calculated. Two different impression techniques (reposition/pickup) and four impression materials (Aquasil Ultra, Flexitime, Impregum Penta, P2 Magnum 360) were investigated. In all, 80 implant impressions for each implant system were taken. Statistical analysis was performed using multivariate analysis of variance. The implant system significantly influenced the transfer accuracy for most spatial dimensions, including the overall 3D shift and implant axis direction. There was no significant difference between the two implant systems with regard to rotation. Multivariate analysis of variance showed a significant effect on transfer accuracy only for the implant system. Within the limits of the present study, it can be concluded that the transfer accuracy of the intraoral implant position on the working cast is far more dependent on the implant system than on the selection of a specific impression technique or material.

  13. Calcium and Titanium Isotope Fractionation in CAIS: Tracers of Condensation and Inheritance in the Early Solar Protoplanetary Disk

    Science.gov (United States)

    Simon, J. I.; Jordan, M. K.; Tappa, M. J.; Kohl, I. E.; Young, E. D.

    2016-01-01

    The chemical and isotopic compositions of calcium-aluminum-rich inclusions (CAIs) can be used to understand the conditions present in the protoplantary disk where they formed. The isotopic compositions of these early-formed nebular materials are largely controlled by chemical volatility. The isotopic effects of evaporation/sublimation, which are well explained by both theory and experimental work, lead to enrichments of the heavy isotopes that are often exhibited by the moderately refractory elements Mg and Si. Less well understood are the isotopic effects of condensation, which limits our ability to determine whether a CAI is a primary condensate and/or retains any evidence of its primordial formation history.

  14. Retention system for implant-supported dentures used by brazilian dentists who work in implant dentistry

    Directory of Open Access Journals (Sweden)

    Saturnino Aparecido Ramalho

    2010-04-01

    Full Text Available Objective: To provide the dentists with support in the choice of the cement or screw type of retention for implant-supported dentures, according to the patient’s problem. Methods: An opinion questionnaire was applied to a sample of 468 participants, all dentists working in the field of Implant Dentistry, of whom 272 (58.1% participated in the 4th International Congress of Osseointegration of APCD, held in São Paulo (SP from 6 to 9 May 2004, 119 (25.4% participated in the 2nd International Congress of Implant Dentistry of Minas Gerais, between 10 and 12 June 2004 and 77 (16.5% were professors and specialization and master students from São Leopoldo Mandic. Results: The results showed that 254 participants opted for the screw-retained system while 214 opted for the cement-retained system. Conclusion: There was a preference for the use of the screw-retained system, and that both cemented and screw-retained systems have advantages and disadvantages, so that the dentist is left to decide and evaluate them in order to indicate and use them with confidence in different clinical cases.

  15. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

    OpenAIRE

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung; Jeong, Chang-Mo

    2014-01-01

    PURPOSE This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess ...

  16. An experimental study of fuel injection strategies in CAI gasoline engine

    Energy Technology Data Exchange (ETDEWEB)

    Hunicz, J.; Kordos, P. [Department of Combustion Engines and Transport, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin (Poland)

    2011-01-15

    Combustion of gasoline in a direct injection controlled auto-ignition (CAI) single-cylinder research engine was studied. CAI operation was achieved with the use of the negative valve overlap (NVO) technique and internal exhaust gas re-circulation (EGR). Experiments were performed at single injection and split injection, where some amount of fuel was injected close to top dead centre (TDC) during NVO interval, and the second injection was applied with variable timing. Additionally, combustion at variable fuel-rail pressure was examined. Investigation showed that at fuel injection into recompressed exhaust fuel reforming took place. This process was identified via an analysis of the exhaust-fuel mixture composition after NVO interval. It was found that at single fuel injection in NVO phase, its advance determined the heat release rate and auto-ignition timing, and had a strong influence on NO{sub X} emission. However, a delay of single injection to intake stroke resulted in deterioration of cycle-to-cycle variability. Application of split injection showed benefits of this strategy versus single injection. Examinations of different fuel mass split ratios and variable second injection timing resulted in further optimisation of mixture formation. At equal share of the fuel mass injected in the first injection during NVO and in the second injection at the beginning of compression, the lowest emission level and cyclic variability improvement were observed. (author)

  17. The bacterial sealing capacity of morse taper implant-abutment systems in vitro.

    Science.gov (United States)

    Ranieri, Rogerio; Ferreira, Andreia; Souza, Emmanuel; Arcoverde, Joao; Dametto, Fabio; Gade-Neto, Cicero; Seabra, Flavio; Sarmento, Carlos

    2015-05-01

    The use of Morse taper systems in dental implantology has been associated widely with a more precise adaptation between implants and their respective abutments. This may lead to an increase in the stability of the implant system and may also prevent microbial invasion through the implant-abutment interface. The aim of this study was to investigate in vitro the ability of four commercially available Morse taper system units to impede bacterial penetration through their implant-abutment interfaces. Abutments were screwed onto the implants, and the units were subsequently immersed in Streptococcus sanguinis bacterial broth (1 × 10(8) colony forming units/mL) for 48 hours. The units were examined by scanning electron microscopy (SEM) under three conditions: 1) with the implant-abutment components assembled as units to investigate for both the existence of microgaps and the presence of bacteria; 2) with the implants and abutments separated for examination of internal surfaces; and 3) with the implant-abutment components again assembled as units to measure any microgaps detected. The mean size of the microgaps in each unit was determined by measuring, under SEM, their width in four equidistant points. Microgaps were detected in all units with no significant differences in dimension (Kruskal-Wallis test, P >0.05). Within all units, the presence of bacteria was also observed. The seals provided by the interfaces of the commercially available Morse taper implant-abutment units tested were not sufficiently small to shield the implant from bacterial penetration.

  18. [Design and application of implantable medical device information management system].

    Science.gov (United States)

    Cao, Shaoping; Yin, Chunguang; Zhao, Zhenying

    2013-03-01

    Through the establishment of implantable medical device information management system, with the aid of the regional joint sharing of resources, we further enhance the implantable medical device traceability management level, strengthen quality management, control of medical risk.

  19. Sinking and fit of abutment of locking taper implant system

    Science.gov (United States)

    Moon, Seung-Jin; Kim, Hee-Jung; Son, Mee-Kyoung

    2009-01-01

    STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS 10 Bicon® implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS It was evident, that the amount of abutment sinking in Bicon® Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 ± 0.09 mm. CONCLUSION Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location. PMID:21165262

  20. The First Expert CAI System

    Science.gov (United States)

    Feurzeig, Wallace

    1984-01-01

    The first expert instructional system, the Socratic System, was developed in 1964. One of the earliest applications of this system was in the area of differential diagnosis in clinical medicine. The power of the underlying instructional paradigm was demonstrated and the potential of the approach for valuably supplementing medical instruction was recognized. Twenty years later, despite further educationally significant advances in expert systems technology and enormous reductions in the cost of computers, expert instructional methods have found very little application in medical schools.

  1. Three-dimensional accuracy of plastic transfer impression copings for three implant systems.

    Science.gov (United States)

    Teo, Juin Wei; Tan, Keson B; Nicholls, Jack I; Wong, Keng Mun; Uy, Joanne

    2014-01-01

    The purpose of this study was to compare the three-dimensional accuracy of indirect plastic impression copings and direct implant-level impression copings from three implant systems (Nobel Biocare [NB], Biomet 3i [3i], and Straumann [STR]) at three interimplant buccolingual angulations (0, 8, and 15 degrees). Two-implant master models were used to simulate a three-unit implant fixed partial denture. Test models were made from Impregum impressions using direct implant-level impression copings (DR). Abutments were then connected to the master models for impressions using the plastic impression copings (INDR) at three different angulations for a total of 18 test groups (n = 5 in each group). A coordinate measuring machine was used to measure linear distortions, three-dimensional (3D) distortions, angular distortions, and absolute angular distortions between the master and test models. Three-way analysis of variance showed that the implant system had a significant effect on 3D distortions and absolute angular distortions in the x- and y-axes. Interimplant angulation had a significant effect on 3D distortions and absolute angular distortions in the y-axis. Impression technique had a significant effect on absolute angular distortions in the y-axis. With DR, the NB and 3i systems were not significantly different. With INDR, 3i appeared to have less distortion than the other systems. Interimplant angulations did not significantly affect the accuracy of NBDR, 3iINDR, and STRINDR. The accuracy of INDR and DR was comparable at all interimplant angulations for 3i and STR. For NB, INDR was comparable to DR at 0 and 8 degrees but was less accurate at 15 degrees. Three-dimensional accuracy of implant impressions varied with implant system, interimplant angulation, and impression technique.

  2. Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study.

    Science.gov (United States)

    Lenders, Guy D; Collas, Valérie; Hernandez, José Maria; Legrand, Victor; Danenberg, Haim D; den Heijer, Peter; Rodrigus, Inez E; Paelinck, Bernard P; Vrints, Christiaan J; Bosmans, Johan M

    2014-10-20

    Transcatheter Aortic Valve Implantation (TAVI) is now considered an indispensable treatment strategy in high operative risk patients with severe, symptomatic aortic stenosis. However, conduction disturbances and the need for Permanent Pacemaker (PPM) implantation after TAVI with the CoreValve prosthesis still remain frequent. We aimed to evaluate the implantation depth, the incidence and predictors of new conduction disturbances, and the need for PPM implantation within the first month after TAVI, using the new Accutrak CoreValve delivery system (ACV), compared to the previous generation CoreValve (non-ACV). In 5 experienced TAVI-centers, a total of 120 consecutive non-ACV and 112 consecutive ACV patients were included (n=232). The mean depth of valve implantation (DVI) was 8.4±4.0 mm in the non-ACV group and 7.1±4.0 mm in the ACV group (p=0.034). The combined incidence of new PPM implantation and new LBBB was 71.2% in the non-ACV group compared to 50.5% in the ACV group (p=0.014). DVI (p=0.002), first degree AV block (p=0.018) and RBBB (p<0.001) were independent predictors of PPM implantation. DVI (p<0.001) and pre-existing first degree AV-block (p=0.021) were identified as significant predictors of new LBBB. DVI is an independent predictor of TAVI-related conduction disturbances and can be reduced by using the newer CoreValve Accutrak delivery system, resulting in a significantly lower incidence of new LBBB and new PPM implantation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. ISHTE deep-ocean corers and heater-implant system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Olson, L. O.; Harrison, J. G.

    1982-09-01

    Seafloor instrumentation systems are being developed for the In-Situ Heat Transfer Experiment (ISHTE) to determine the thermal conductivity of deep ocean sediments. As part of the experiment, a heat canister will be implanted into the sediment. Also, after about one year on the seafloor, core samplers are to be actuated to gather sediment samples. This report describes the deep ocean piston corers and the heater-implant drive system.

  4. Three-Dimensional Implant Positioning with a Piezosurgery Implant Site Preparation Technique and an Intraoral Surgical Navigation System: Case Report.

    Science.gov (United States)

    Pellegrino, Gerardo; Taraschi, Valerio; Vercellotti, Tomaso; Ben-Nissan, Besim; Marchetti, Claudio

    This case report describes new implant site preparation techniques joining the benefits of using an intraoral navigation system to optimize three-dimensional implant site positioning in combination with an ultrasonic osteotomy. A report of five patients is presented, and the implant positions as planned in the navigation software with the postoperative scan image were compared. The preliminary results are useful, although further clinical studies with larger populations are needed to confirm these findings.

  5. Implant Surface Temperature Changes during Er:YAG Laser Irradiation with Different Cooling Systems.

    Directory of Open Access Journals (Sweden)

    Abbas Monzavi

    2014-04-01

    Full Text Available Peri-implantitis is one of the most common reasons for implant failure. Decontamination of infected implant surfaces can be achieved effectively by laser irradiation; although the associated thermal rise may cause irreversible bone damage and lead to implant loss. Temperature increments of over 10ºC during laser application may suffice for irreversible bone damage.The purpose of this study was to evaluate the temperature increment of implant surface during Er:YAG laser irradiation with different cooling systems.Three implants were placed in a resected block of sheep mandible and irradiated with Er:YAG laser with 3 different cooling systems namely water and air spray, air spray alone and no water or air spray. Temperature changes of the implant surface were monitored during laser irradiation with a K-type thermocouple at the apical area of the fixture.In all 3 groups, the maximum temperature rise was lower than 10°C. Temperature changes were significantly different with different cooling systems used (P<0.001.Based on the results, no thermal damage was observed during implant surface decontamination by Er:YAG laser with and without refrigeration. Thus, Er:YAG laser irradiation can be a safe method for treatment of periimplantitis.

  6. EVIDENCE FOR MULTIPLE SOURCES OF 10Be IN THE EARLY SOLAR SYSTEM

    International Nuclear Information System (INIS)

    Wielandt, Daniel; Krot, Alexander N.; Bizzarro, Martin; Nagashima, Kazuhide; Huss, Gary R.; Ivanova, Marina A.

    2012-01-01

    Beryllium-10 is a short-lived radionuclide (t 1/2 = 1.4 Myr) uniquely synthesized by spallation reactions and inferred to have been present when the solar system's oldest solids (calcium-aluminum-rich inclusions, CAIs) formed. Yet, the astrophysical site of 10 Be nucleosynthesis is uncertain. We report Li-Be-B isotope measurements of CAIs from CV chondrites, including CAIs that formed with the canonical 26 Al/ 27 Al ratio of ∼5 × 10 –5 (canonical CAIs) and CAIs with Fractionation and Unidentified Nuclear isotope effects (FUN-CAIs) characterized by 26 Al/ 27 Al ratios much lower than the canonical value. Our measurements demonstrate the presence of four distinct fossil 10 Be/ 9 Be isochrons, lower in the FUN-CAIs than in the canonical CAIs, and variable within these classes. Given that FUN-CAI precursors escaped evaporation-recondensation prior to evaporative melting, we suggest that the 10 Be/ 9 Be ratio recorded by FUN-CAIs represents a baseline level present in presolar material inherited from the protosolar molecular cloud, generated via enhanced trapping of galactic cosmic rays. The higher and possibly variable apparent 10 Be/ 9 Be ratios of canonical CAIs reflect additional spallogenesis, either in the gaseous CAI-forming reservoir, or in the inclusions themselves: this indicates at least two nucleosynthetic sources of 10 Be in the early solar system. The most promising locale for 10 Be synthesis is close to the proto-Sun during its early mass-accreting stages, as these are thought to coincide with periods of intense particle irradiation occurring on timescales significantly shorter than the formation interval of canonical CAIs.

  7. Changes of Benthic Macroinvertebrates in Thi Vai River and Cai Mep Estuaries Under Polluted Conditions with Industrial Wastewater

    Directory of Open Access Journals (Sweden)

    Huong Nguyen Thi Thanh

    2017-06-01

    Full Text Available The pollution on the Thi Vai River has been spreading out rapidly over the two lasted decades caused by the wastewater from the industrial parks in the left bank of Thi Vai River and Cai Mep Estuaries. The evaluation of the benthic macroinvertebrate changes was very necessary to identify the consequences of the industrial wastewater on water quality and aquatic ecosystem of Thi Vai River and Cai Mep Estuaries. In this study, the variables of benthic macroinvertebrates and water quality were investigated in Thi Vai River and Cai Mep Estuaries, Southern Vietnam. The monitoring data of benthic macroinvertebrates and water quality parameters covered the period from 1989 to 2015 at 6 sampling sites in Thi Vai River and Cai Mep Estuaries. The basic water quality parameters were also tested including pH, dissolved oxygen (DO, total nitrogen, and total phosphorus. The biodiversity indices of benthic macroinvertebrates were applied for water quality assessment. The results showed that pH ranged from 6.4 – 7.6 during the monitoring. The DO concentrations were in between 0.20 - 6.70 mg/L. The concentrations of total nitrogen and total phosphorous ranged from 0.03 - 5.70 mg/L 0.024 - 1.380 mg/L respectively. Macroinvertebrate community in the study area consisted of 36 species of polychaeta, gastropoda, bivalvia, and crustacea, of which, species of polychaeta were dominant in species number. The benthic macroinvertebartes density ranged from 0 - 2.746 individuals/m−1 with the main dominant species of Neanthes caudata, Prionospio malmgreni, Paraprionospio pinnata, Trichochaeta carica, Maldane sarsi, Capitella capitata, Terebellides stroemi, Euditylia polymorpha, Grandidierella lignorum, Apseudes vietnamensis. The biodiversity index values during the monitoring characterized for aquatic environmental conditions of mesotrophic to polytrophic. Besides, species richness positively correlated with DO, total nitrogen, and total phosphorus. The results

  8. Design of an end station for a high current ion implantation system

    International Nuclear Information System (INIS)

    Kranik, J.R.

    1979-01-01

    During the last 4 to 5 years IBM has been involved in an effort to develop a high current Ion Implantation system with pre-deposition capabilities. The system is dedicated to Arsenic implants, involving doses > 1 x 10 15 ions/cm 2 in the energy range of 30 to 60 keV. A major portion of this effort involved the design of an associated end station capable of producing high uniformity implants with beam currents in the 0.5 to 6.0 mA range. The end station contains all components from the exit of the analyzing magnet, including the exit beamline, process chamber, scan system, wafer handling system, high vacuum pumping package, beam optics, dosimetry system, and associated electronic controls. The unit was restricted to a six wafer (82 mm) batch size to maintain process line compatibility. In addition, implant dose non-uniformity objectives were established at +- 3% (2σ) within a wafer and +- 2% (2σ) wafer-to-wafer. Also, the system was to be capable of implanting 24 wafers/hour at a dose of 7.5 x 10 15 ions/cm 2 . Major consideration in the design was afforded to high reliability, ease of maintenance and production level throughput capabilities. The rationale and evolution of the final end station design is described. (author)

  9. Electroacoustic verification of frequency modulation systems in cochlear implant users.

    Science.gov (United States)

    Fidêncio, Vanessa Luisa Destro; Jacob, Regina Tangerino de Souza; Tanamati, Liége Franzini; Bucuvic, Érika Cristina; Moret, Adriane Lima Mortari

    2017-12-26

    The frequency modulation system is a device that helps to improve speech perception in noise and is considered the most beneficial approach to improve speech recognition in noise in cochlear implant users. According to guidelines, there is a need to perform a check before fitting the frequency modulation system. Although there are recommendations regarding the behavioral tests that should be performed at the fitting of the frequency modulation system to cochlear implant users, there are no published recommendations regarding the electroacoustic test that should be performed. Perform and determine the validity of an electroacoustic verification test for frequency modulation systems coupled to different cochlear implant speech processors. The sample included 40 participants between 5 and 18 year's users of four different models of speech processors. For the electroacoustic evaluation, we used the Audioscan Verifit device with the HA-1 coupler and the listening check devices corresponding to each speech processor model. In cases where the transparency was not achieved, a modification was made in the frequency modulation gain adjustment and we used the Brazilian version of the "Phrases in Noise Test" to evaluate the speech perception in competitive noise. It was observed that there was transparency between the frequency modulation system and the cochlear implant in 85% of the participants evaluated. After adjusting the gain of the frequency modulation receiver in the other participants, the devices showed transparency when the electroacoustic verification test was repeated. It was also observed that patients demonstrated better performance in speech perception in noise after a new adjustment, that is, in these cases; the electroacoustic transparency caused behavioral transparency. The electroacoustic evaluation protocol suggested was effective in evaluation of transparency between the frequency modulation system and the cochlear implant. Performing the adjustment of

  10. Clinical evaluation of a novel dental implant system as single implants under immediate loading conditions - 4-month post-loading results from a multicentre randomised controlled trial.

    Science.gov (United States)

    Esposito, Marco; Trullenque-Eriksson, Anna; Blasone, Rodolfo; Malaguti, Giuliano; Gaffuri, Cristiano; Caneva, Marco; Minciarelli, Armando; Luongo, Giuseppe

    To evaluate the safety and clinical effectiveness of a novel dental implant system (GENESIS Implant System, Keystone Dental, Massachusetts, USA) using another dental implant system by the same manufacturer as a control (PRIMA Implant System, Keystone Dental). A total of 53 patients requiring at least two single crowns had their sites randomised according to a split-mouth design to receive both implant systems at six centres. If implants could be placed with a torque superior to 40 Ncm they were to be loaded immediately with provisional crowns, otherwise after 3 months of submerged healing. Provisional crowns were replaced by definitive crowns 4 months after initial loading, when the follow-up period for the initial part of this study was completed. Outcome measures were crown/implant failures, complications, pink esthetic score (PES), peri-implant marginal bone level changes, plaque score, marginal bleeding, patients and preference of the clinician. In total 53 PRIMA and 53 GENESIS implants were placed. Three patients dropped out but all of the remaining patients were followed up to 4-months post-loading. No PRIMA implant failed whereas four GENESIS implants failed. Only two complications were reported for PRIMA implants. There were no statistically significant differences for crown/implant failures (difference in proportions = 0.080; P (McNemar test) = 0.125) and complications (difference in proportions = -0.04; P (McNemar test) = 0.500) between the implant systems. There were no differences at 4-months post-loading for plaque (difference = -0.54, 95% CI: -3.01 to 1.93; P (Paired t-test) = 0.660), marginal bleeding (difference = -3.8, 95% CI: -7.63 to 0.019; P (Paired t-test) = 0.051), PES (difference = 0.47, 95% CI: -0.56 to 1.50; P (Paired t-test) = 0.365) and marginal bone level changes (difference in mm = -0.04, 95% CI: -0.33 to 0.26; P (Paired t-test) = 0.795). The majority of the patients (46) had no

  11. Vehicle/Guideway Interaction in Maglev Systems

    Science.gov (United States)

    1992-03-01

    Technology Division Materials and Components in Maglev Systems Technology Division Materials and Components Technology Division byY. Cai, S. S. Chen, and D. M...Transportation Systems Reports (UC-330, Vehicle/Guideway Interaction in Maglev Systems by Y. Cai and S. S. Chen Materials and Components Technology Division D. M...Surface Irregularities ...................................... 32 4 Vehicle/Guideway Interaction in Transrapid Maglev System .................. 34 4.1

  12. Effects on cuytoskeleton system in pollen tube of pinus thunbergii induced by ion beam implantation

    International Nuclear Information System (INIS)

    Huang Qunce; Liang Qiuxia; Li Guopin

    2008-01-01

    The damage of the cytoskeleton system in the pollen and the pollen tube of Pinus thunbergii induced by ion beam implantation were researched. The results showed that the disorganization of the micro-tubules in the pollen tube was produced by N + implantation. The abnormal states of the pollen tube in morphology were very correlative with the abnormality of the cytoskeleton system. N + implantation was responsible for morphological abnormalities in the pollen tubes. There was a distinct correlation between the damage effects and the ion implantation dose. The add of dose caused more obvious damage effects. Furthermore, the state of the cytoskeleton system in the pollen tube was influenced by the ion implantation. The impact grade depended also on the ion implantation dose. (authors)

  13. On native Danish learners' challenges in distinguishing /tai/, /cai/ and /zai/

    DEFF Research Database (Denmark)

    Sloos, Marjoleine; Zhang, Chun

    2015-01-01

    University participated in an ABX experiment. They were auditorily presented pairs of the critical stimuli tai-cai-zai, te-ce-ze and tuo-cuo-zuo combined with all four tones and alternated with fillers. The subjects indicated for each pair which of the two words matched the pinyin description. The expected...... results show that beginner learners perform on chance level regarding the distinction between t and z and between c and z. The reason is that in Danish, which has an aspiration contrast between plosives (like Chinese) /th/ is variably pronounced as affricated /ts/ and many speakers are unaware...

  14. Processing of microCT implant-bone systems images using Fuzzy Mathematical Morphology

    International Nuclear Information System (INIS)

    Bouchet, A; Pastore, J; Colabella, L; Omar, S; Ballarre, J

    2016-01-01

    The relationship between a metallic implant and the existing bone in a surgical permanent prosthesis is of great importance since the fixation and osseointegration of the system leads to the failure or success of the surgery. Micro Computed Tomography is a technique that helps to visualize the structure of the bone. In this study, the microCT is used to analyze implant-bone systems images. However, one of the problems presented in the reconstruction of these images is the effect of the iron based implants, with a halo or fluorescence scattering distorting the micro CT image and leading to bad 3D reconstructions. In this work we introduce an automatic method for eliminate the effect of AISI 316L iron materials in the implant-bone system based on the application of Compensatory Fuzzy Mathematical Morphology for future investigate about the structural and mechanical properties of bone and cancellous materials. (paper)

  15. A Wireless Implantable Switched-Capacitor Based Optogenetic Stimulating System

    Science.gov (United States)

    Lee, Hyung-Min; Kwon, Ki-Yong; Li, Wen

    2015-01-01

    This paper presents a power-efficient implantable optogenetic interface using a wireless switched-capacitor based stimulating (SCS) system. The SCS efficiently charges storage capacitors directly from an inductive link and periodically discharges them into an array of micro-LEDs, providing high instantaneous power without affecting wireless link and system supply voltage. A custom-designed computer interface in LabVIEW environment wirelessly controls stimulation parameters through the inductive link, and an optrode array enables simultaneous neural recording along with optical stimulation. The 4-channel SCS system prototype has been implemented in a 0.35-μm CMOS process and combined with the optrode array. In vivo experiments involving light-induced local field potentials verified the efficacy of the SCS system. An implantable version of the SCS system with flexible hermetic sealing is under development for chronic experiments. PMID:25570099

  16. Implantable electronics of a closed-loop system for controlling prosthetic hands

    Directory of Open Access Journals (Sweden)

    Nikas Antonios

    2017-09-01

    Full Text Available This paper presents the design of implantable electronics as a part of a system for prosthetic hand control. Purpose of the implant is the sensing of electrical signals originating from biological tissue and the actuation of the same, therefore closing the loop and allowing for an improved control of the prosthetic hand. The implant contains two integrated circuits for eight channel EMG monitoring and four channel stimulation, respectively. An on-board microcontroller allows for local pre-processing. All intracorporeal to extracorporeal communications are running through and are directed by the main processing platform. The external components of the control system include, in addition to the main processing and control platform, the inductive power transfer circuits and the pressure sensors for the sensory feedback. Different assembly and encapsulation options are taken into account for the implantable electronics and are unified in a single PCB design.

  17. Finite element analysis to compare complete denture and implant-retained overdentures with different attachment systems.

    Science.gov (United States)

    Barão, Valentim Adelino Ricardo; Assunção, Wirley Gonçalves; Tabata, Lucas Fernando; Delben, Juliana Aparecida; Gomes, Erica Alves; de Sousa, Edson Antonio Capello; Rocha, Eduardo Passos

    2009-07-01

    This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred in supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

  18. Bird community structure in riparian environments in Cai River, Rio Grande do Sul, Brazil

    OpenAIRE

    Jaqueline Brummelhaus; Marcia Suelí Bohn; Maria Virginia Petry

    2012-01-01

    Urbanization produces changes in riparian environments, causing effects in the structure of bird communities, which present different responses to the impacts. We compare species richness, abundance, and composition of birds in riparian environments with different characteristics in Cai River, Rio Grande do Sul, Brazil. We carried out observations in woodland, grassland, and urban environments, between September 2007 and August 2008. We listed 130 bird species, 29 species unique to woodland e...

  19. The influence of micro and macro-geometry in term of bone-implant interface in two implant systems: an histomorphometrical study.

    Science.gov (United States)

    Rocci, A; Calcaterra, R; DI Girolamo, M; Rocci, M; Rocci, C; Baggi, L

    2015-01-01

    Many factors could affect the osseous healing of implants such as surface topography of biomaterial, the status of the bone/implant site, implant loading conditions, surgical technique and implant design. The aim of this study was to analyze the BIC of 2 different implants systems characterized by different micro and macrogeometry, that were placed in the posterior maxillary and mandibular jaws of humans, clinically unloaded and retrieved for histomorphometric analyses after 12 weeks. The patients were divided in two groups (Group I and II); group I was composed by 4 patients that each received in the posterior areas of mandible one type A implant [GTB-Plan1Health Amaro (UD) Italy] one type B implant (OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). Group II was composed by 3 patients that each received in the posterior areas of jawsbone one type A implant [GTB-Plan1Health Amaro (UD) Italy] one type B implant (OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). After 12 weeks of healing all the implants of both groups were harvested with the peri-implant bone tissues. Osseointegration process was evaluated throughout measurements of BIC. No statistical significance differences were found among the mean percentage of BIC of Group I - type A were 66,51% versus 49,96% in Group I - type B, as well as among the mean percentage of BIC of Group II - type A were 43.7% versus 60.02% in Group II - type B. Our results highlight that the mean percentage of BIC after 12 weeks from the implants placement without functional loading is not influenced by the composition of the implant surface.

  20. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

    Science.gov (United States)

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung; Jeong, Chang-Mo

    2014-12-01

    This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (Pabutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

  1. Architecture and control of a high current ion implanter system

    International Nuclear Information System (INIS)

    Bayer, E.H.; Paul, L.F.; Kranik, J.R.

    1979-01-01

    The design of an ion implant system for use in production requires that special attention be given to areas of design which normally are not emphasized on research or development type ion implanters. Manually operated, local controls are replaced by remote controls, automatic sequencing, and digital displays. For ease of maintenance and replication the individual components are designed as simply as possible and are contained in modules of separate identities, joined only by the beam line and electrical interconnections. A production environment also imposes requirements for the control of contamination and maintainability of clean room integrity. For that reason the major portion of the hardware is separated from the clean operator area and is housed in a maintenance core area. The controls of a production system should also be such that relatively unskilled technicians are able to operate the system with optimum repeatability and minimum operator intervention. An extensive interlock system is required. Most important, for use in production the ion implant system has to have a relatively high rate of throughput. Since the rate of throughput at a given dose is a function of beam current, pumpdown time and wafer handling capacity, design of components affecting these parameters has been optimized. Details of the system are given. (U.K.)

  2. New orthopaedic implant management tool for computer-assisted planning, navigation, and simulation: from implant CAD files to a standardized XML-based implant database.

    Science.gov (United States)

    Sagbo, S; Blochaou, F; Langlotz, F; Vangenot, C; Nolte, L-P; Zheng, G

    2005-01-01

    Computer-Assisted Orthopaedic Surgery (CAOS) has made much progress over the last 10 years. Navigation systems have been recognized as important tools that help surgeons, and various such systems have been developed. A disadvantage of these systems is that they use non-standard formalisms and techniques. As a result, there are no standard concepts for implant and tool management or data formats to store information for use in 3D planning and navigation. We addressed these limitations and developed a practical and generic solution that offers benefits for surgeons, implant manufacturers, and CAS application developers. We developed a virtual implant database containing geometrical as well as calibration information for orthopedic implants and instruments, with a focus on trauma. This database has been successfully tested for various applications in the client/server mode. The implant information is not static, however, because manufacturers periodically revise their implants, resulting in the deletion of some implants and the introduction of new ones. Tracking these continuous changes and keeping CAS systems up to date is a tedious task if done manually. This leads to additional costs for system development, and some errors are inevitably generated due to the huge amount of information that has to be processed. To ease management with respect to implant life cycle, we developed a tool to assist end-users (surgeons, hospitals, CAS system providers, and implant manufacturers) in managing their implants. Our system can be used for pre-operative planning and intra-operative navigation, and also for any surgical simulation involving orthopedic implants. Currently, this tool allows addition of new implants, modification of existing ones, deletion of obsolete implants, export of a given implant, and also creation of backups. Our implant management system has been successfully tested in the laboratory with very promising results. It makes it possible to fill the current gap

  3. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    OpenAIRE

    Sanjay Byakodi; Sachin Kumar; Rajesh Kumar Reddy; Vipin Kumar; Shipra Sepolia; Shivangi Gupta; Harkanwal Preet Singh

    2017-01-01

    Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental i...

  4. In Vitro Evaluation of Leakage at Implant-Abutment Connection of Three Implant Systems Having the Same Prosthetic Interface Using Rhodamine B

    Directory of Open Access Journals (Sweden)

    Antoine Berberi

    2014-01-01

    Full Text Available Objectives. Hollow space between implant and abutment may act as reservoir for commensal and/or pathogenic bacteria representing a potential source of tissue inflammation. Microbial colonization of the interfacial gap may ultimately lead to infection and bone resorption. Using Rhodamine B, a sensitive fluorescent tracer dye, we aim in this study to investigate leakage at implant-abutment connection of three implant systems having the same prosthetic interface. Materials and Methods. Twenty-one implants (seven Astra Tech, seven Euroteknika, and seven Dentium with the same prosthetic interface were connected to their original abutments, according to the manufacturers’ recommendation. After determination of the inner volume of each implant systems, the kinetic quantification of leakage was evaluated for each group using Rhodamine B (10−2 M. For each group, spectrophotometric analysis was performed to detect leakage with a fluorescence spectrophotometer at 1 h (T0 and 48 h (T1 of incubation time at room temperature. Results. Astra Tech had the highest inner volume (6.8 μL, compared to Dentium (4 μL and Euroteknika (2.9 μL. At T0 and T1, respectively, the leakage volume and percentage of each system were as follows: Astra Tech 0.043 μL or 1.48% (SD 0.0022, 0.08 μL or 5.56% (SD 0.0074, Euroteknika 0.09 μL or 6.93% (SD 0.0913, 0.21 μL or 20.55% (SD 0.0035, and Dentium 0.07 μL or 4.6% (SD 0.0029, 0.12 μL or 10.47% (SD 0.0072. Conclusion. The tested internal conical implant-abutment connections appear to be unable to prevent leakage. In average, Astra Tech implants showed the highest inner volume and the least leakage.

  5. Systemic antibiotics and the risk of superinfection in peri-implantitis.

    Science.gov (United States)

    Verdugo, Fernando; Laksmana, Theresia; Uribarri, Agurne

    2016-04-01

    Peri-implantitis has emerged in the last few years as a complication difficult to resolve. The etiopathogenesis consensus is mainly attributed to bacteria. Following the preferred reporting items for systematic reviews and meta-analysis (PRISMA) guidelines, a PubMed/Medline literature search was performed using the US National Library of Medicine database up to 2015 to analyze available scientific data on the rationale and risk of superinfection associated to systemic antimicrobials in human peri-implant disease. A hand search was also conducted on relevant medical and microbiology journals. The methodological index for non-randomized studies (MINORS) was independently assessed for quality on the selected papers. Proposed combined therapies use broad-spectrum antibiotics to halt the disease progression. A major associated risk, particularly when prescribed empirically without microbiological follow-up, is the undetected development of superinfections and overgrowth of opportunistic pathogens difficult to eradicate. Peri-implant superinfections with opportunistic bacteria, yeast and viruses, are plausible risks associated to the use of systemic antibiotics in immunocompetent individuals. Lack of microbiological follow-up and antibiotic susceptibility testing may lead to ongoing microbial challenges that exacerbate the disease progression. The increased proliferation of antimicrobial resistance, modern implant surface topography and indiscriminative empiric antibiotic regimens may promote the escalation of peri-implant disease in years to come. A personalized 3-month supportive therapy may help prevent risks by sustaining a normal ecological balance, decreasing specific pathogen proportions and maintaining ideal plaque control. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Isotopic coherence of refractory inclusions from CV and CK meteorites: Evidence from multiple isotope systems

    Science.gov (United States)

    Shollenberger, Quinn R.; Borg, Lars E.; Render, Jan; Ebert, Samuel; Bischoff, Addi; Russell, Sara S.; Brennecka, Gregory A.

    2018-05-01

    Calcium-aluminum-rich inclusions (CAIs) are the oldest dated materials in the Solar System and numerous previous studies have revealed nucleosynthetic anomalies relative to terrestrial rock standards in many isotopic systems. However, most of the isotopic data from CAIs has been limited to the Allende meteorite and a handful of other CV3 chondrites. To better constrain the isotopic composition of the CAI-forming region, we report the first Sr, Mo, Ba, Nd, and Sm isotopic compositions of two CAIs hosted in the CK3 desert meteorites NWA 4964 and NWA 6254 along with two CAIs from the CV3 desert meteorites NWA 6619 and NWA 6991. After consideration of neutron capture processes and the effects of hot-desert weathering, the Sr, Mo, Ba, Nd, and Sm stable isotopic compositions of the samples show clearly resolvable nucleosynthetic anomalies that are in agreement with previous results from Allende and other CV meteorites. The extent of neutron capture, as manifested by shifts in the observed 149Sm-150Sm isotopic composition of the CAIs is used to estimate the neutron fluence experienced by some of these samples and ranges from 8.40 × 1013 to 2.11 × 1015 n/cm2. Overall, regardless of CAI type or host meteorite, CAIs from CV and CK chondrites have similar nucleosynthetic anomalies within analytical uncertainty. We suggest the region that CV and CK CAIs formed was largely uniform with respect to Sr, Mo, Ba, Nd, and Sm isotopes when CAIs condensed and that CAIs hosted in CV and CK meteorites are derived from the same isotopic reservoir.

  7. The possibility of controlled auto-ignition (CAI) in gasoline engine and gas to liquid (GTL) as a fuel of diesel engine in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, D. [Korea Inst. of Machinery and Materials, Daejou (Korea)

    2005-07-01

    A significant challenge grows from the ever-increasing demands for the optimization of performance, emissions, fuel economy and drivability. The most powerful technologies in the near future to improve these factors are believed Controlled Auto-Ignition (CAI) in gasoline engine and Gas to Liquid (GTL) as a fuel of Diesel engine. In recent years there has been an increasing trend to use more complex valvetrain designs from traditional camshaft driven mechanical systems to camless electromagnetic or electrohydraulic solutions. Comparing to fixed valve actuation systems, variable valve actuation (VVA) should be powerful to optimize the engine cycle. The matching of valve events to the engine performance and to emission requirements at a given engine or vehicle operating condition can be further optimized to the Controlled Auto-Ignition (CAI) in gasoline engine, which has benefits in NOx emission, fuel consumption, combustion stability and intake throttle load. In case of Diesel engine, the increasing demands for NOx and soot emission reduction have introduced aftertreatment technologies recently, but been in need of basic solution for the future, such as a super clean fuel like Gas to Liquid (GTL), which has benefits in comparability to diesel fuel, independency from crude oil and reduction of CO, THC and soot emissions. Korea looks to the future with these kinds of technologies, and tries to find the possibility for reaching the future targets in the internal combustion engine. (orig.)

  8. Selected Topics on Advanced Information Systems Engineering: Editorial Introduction to the Issue 5 of CSIMQ

    Directory of Open Access Journals (Sweden)

    Janis Grabis

    2015-12-01

    Full Text Available The 5th issue of the journal on Complex Systems Informatics and Modeling (CSIMQ presents extended versions of five papers selected from the CAiSE Forum 2015. The forum was part of the 27th edition of international Conference on Advanced Information Systems engineering (CAiSE 2015, which took place in June 2015 in Stockholm, Sweden. Information systems engineering draws its foundation from various interrelated disciplines including, e.g., conceptual modeling, database systems, business process management, requirements engineering, human computer interaction, and enterprise computing to address various practical challenges in development and application of information systems. The guiding subjects of CAiSE 2015 were Creativity, Ability, and Integrity. The CAiSE Forum aimed at presenting and discussing new ideas and tools related to information systems Engineering.

  9. Multiple Nebular Gas Reservoirs Recorded by Oxygen Isotope Variation in a Spinel-Rich CAI in CO3 MIL 090019

    Science.gov (United States)

    Simon, J. I.; Simon, S. B.; Nguyen, A. N.; Ross, D. K.; Messenger, S.

    2017-07-01

    We conducted NanoSIMS ion imaging studies of a primitive spinel-rich CAI from the MIL 090019 CO3 chondrite. It records radial O-isotopic heterogeneity among multiple occurrences of the same mineral, reflecting distinct nebular O-isotopic reservoirs.

  10. The Pathology of Orthopedic Implant Failure Is Mediated by Innate Immune System Cytokines

    Directory of Open Access Journals (Sweden)

    Stefan Landgraeber

    2014-01-01

    Full Text Available All of the over 1 million total joint replacements implanted in the US each year are expected to eventually fail after 15–25 years of use, due to slow progressive subtle inflammation at the bone implant interface. This inflammatory disease state is caused by implant debris acting, primarily, on innate immune cells, that is, macrophages. This slow progressive pathological bone loss or “aseptic loosening” is a potentially life-threatening condition due to the serious complications in older people (>75 yrs of total joint replacement revision surgery. In some people implant debris (particles and ions from metals can influence the adaptive immune system as well, giving rise to the concept of metal sensitivity. However, a consensus of studies agrees that the dominant form of this response is due to innate reactivity by macrophages to implant debris where both danger (DAMP and pathogen (PAMP signalling elicit cytokine-based inflammatory responses. This paper discusses implant debris induced release of the cytokines and chemokines due to activation of the innate (and the adaptive immune system and the subsequent formation of osteolysis. Different mechanisms of implant-debris reactivity related to the innate immune system are detailed, for example, danger signalling (e.g., IL-1β, IL-18, IL-33, etc., toll-like receptor activation (e.g., IL-6, TNF-α, etc., apoptosis (e.g., caspases 3–9, bone catabolism (e.g., TRAP5b, and hypoxia responses (Hif1-α. Cytokine-based clinical and basic science studies are in progress to provide diagnosis and therapeutic intervention strategies.

  11. The Pathology of Orthopedic Implant Failure Is Mediated by Innate Immune System Cytokines

    Science.gov (United States)

    Landgraeber, Stefan; Jäger, Marcus; Jacobs, Joshua J.; Hallab, Nadim James

    2014-01-01

    All of the over 1 million total joint replacements implanted in the US each year are expected to eventually fail after 15–25 years of use, due to slow progressive subtle inflammation at the bone implant interface. This inflammatory disease state is caused by implant debris acting, primarily, on innate immune cells, that is, macrophages. This slow progressive pathological bone loss or “aseptic loosening” is a potentially life-threatening condition due to the serious complications in older people (>75 yrs) of total joint replacement revision surgery. In some people implant debris (particles and ions from metals) can influence the adaptive immune system as well, giving rise to the concept of metal sensitivity. However, a consensus of studies agrees that the dominant form of this response is due to innate reactivity by macrophages to implant debris where both danger (DAMP) and pathogen (PAMP) signalling elicit cytokine-based inflammatory responses. This paper discusses implant debris induced release of the cytokines and chemokines due to activation of the innate (and the adaptive) immune system and the subsequent formation of osteolysis. Different mechanisms of implant-debris reactivity related to the innate immune system are detailed, for example, danger signalling (e.g., IL-1β, IL-18, IL-33, etc.), toll-like receptor activation (e.g., IL-6, TNF-α, etc.), apoptosis (e.g., caspases 3–9), bone catabolism (e.g., TRAP5b), and hypoxia responses (Hif1-α). Cytokine-based clinical and basic science studies are in progress to provide diagnosis and therapeutic intervention strategies. PMID:24891761

  12. Complete genome sequence of Defluviimonas alba cai42T, a microbial exopolysaccharides producer.

    Science.gov (United States)

    Zhao, Jie-Yu; Geng, Shuang; Xu, Lian; Hu, Bing; Sun, Ji-Quan; Nie, Yong; Tang, Yue-Qin; Wu, Xiao-Lei

    2016-12-10

    Defluviimonas alba cai42 T , isolated from the oil-production water in Xinjiang Oilfield in China, has a strong ability to produce exopolysaccharides (EPS). We hereby present its complete genome sequence information which consists of a circular chromosome and three plasmids. The strain characteristically contains various genes encoding for enzymes involved in EPS biosynthesis, modification, and export. According to the genomic and physiochemical data, it is predicted that the strain has the potential to be utilized in industrial production of microbial EPS. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. The Failure Envelope Concept Applied To The Bone-Dental Implant System.

    Science.gov (United States)

    Korabi, R; Shemtov-Yona, K; Dorogoy, A; Rittel, D

    2017-05-17

    Dental implants interact with the jawbone through their common interface. While the implant is an inert structure, the jawbone is a living one that reacts to mechanical stimuli. Setting aside mechanical failure considerations of the implant, the bone is the main component to be addressed. With most failure criteria being expressed in terms of stress or strain values, their fulfillment can mean structural flow or fracture. However, in addition to those effects, the bony structure is likely to react biologically to the applied loads by dissolution or remodeling, so that additional (strain-based) criteria must be taken into account. While the literature abounds in studies of particular loading configurations, e.g. angle and value of the applied load to the implant, a general study of the admissible implant loads is still missing. This paper introduces the concept of failure envelopes for the dental implant-jawbone system, thereby defining admissible combinations of vertical and lateral loads for various failure criteria of the jawbone. Those envelopes are compared in terms of conservatism, thereby providing a systematic comparison of the various failure criteria and their determination of the admissible loads.

  14. Accuracy of a digital impression system based on parallel confocal laser technology for implants with consideration of operator experience and implant angulation and depth.

    Science.gov (United States)

    Giménez, Beatriz; Özcan, Mutlu; Martínez-Rus, Francisco; Pradíes, Guillermo

    2014-01-01

    To evaluate the accuracy of a digital impression system based on parallel confocal red laser technology, taking into consideration clinical parameters such as operator experience and angulation and depth of implants. A maxillary master model with six implants (located bilaterally in the second molar, second premolar, and lateral incisor positions) was fitted with six polyether ether ketone scan bodies. One second premolar implant was placed with 30 degrees of mesial angulation; the opposite implant was positioned with 30 degrees of distal angulation. The lateral incisor implants were placed 2 or 4 mm subgingivally. Two experienced and two inexperienced operators performed intraoral scanning. Five different interimplant distances were then measured. The files obtained from the scans were imported with reverse-engineering software. Measurements were then made with a coordinate measurement machine, with values from the master model used as reference values. The deviations from the actual values were then calculated. The differences between experienced and inexperienced operators and the effects of different implant angulations and depths were compared statistically. Overall, operator 3 obtained significantly less accurate results. The angulated implants did not significantly influence accuracy compared to the parallel implants. Differences were found in the amount of error in the different quadrants. The second scanned quadrant had significantly worse results than the first scanned quadrant. Impressions of the implants placed at the tissue level were less accurate than implants placed 2 and 4 mm subgingivally. The operator affected the accuracy of measurements, but the performance of the operator was not necessarily dependent on experience. Angulated implants did not decrease the accuracy of the digital impression system tested. The scanned distance affected the predictability of the accuracy of the scanner, and the error increased with the increased length of the

  15. Implementation and validation of an implant-based coordinate system for RSA migration calculation.

    Science.gov (United States)

    Laende, Elise K; Deluzio, Kevin J; Hennigar, Allan W; Dunbar, Michael J

    2009-10-16

    An in vitro radiostereometric analysis (RSA) phantom study of a total knee replacement was carried out to evaluate the effect of implementing two new modifications to the conventional RSA procedure: (i) adding a landmark of the tibial component as an implant marker and (ii) defining an implant-based coordinate system constructed from implant landmarks for the calculation of migration results. The motivation for these two modifications were (i) to improve the representation of the implant by the markers by including the stem tip marker which increases the marker distribution (ii) to recover clinical RSA study cases with insufficient numbers of markers visible in the implant polyethylene and (iii) to eliminate errors in migration calculations due to misalignment of the anatomical axes with the RSA global coordinate system. The translational and rotational phantom studies showed no loss of accuracy with the two new measurement methods. The RSA system employing these methods has a precision of better than 0.05 mm for translations and 0.03 degrees for rotations, and an accuracy of 0.05 mm for translations and 0.15 degrees for rotations. These results indicate that the new methods to improve the interpretability, relevance, and standardization of the results do not compromise precision and accuracy, and are suitable for application to clinical data.

  16. A Design of Computer Aided Instructions (CAI) for Undirected Graphs in the Discrete Math Tutorial (DMT). Part 1.

    Science.gov (United States)

    1990-06-01

    The objective of this thesis research is to create a tutorial for teaching aspects of undirected graphs in discrete math . It is one of the submodules...of the Discrete Math Tutorial (DMT), which is a Computer Aided Instructional (CAI) tool for teaching discrete math to the Naval Academy and the

  17. A Design of Computer Aided Instructions (CAI) for Undirected Graphs in the Discrete Math Tutorial (DMT). Part 2

    Science.gov (United States)

    1990-06-01

    The objective of this thesis research is to create a tutorial for teaching aspects of undirected graphs in discrete math . It is one of the submodules...of the Discrete Math Tutorial (DMT), which is a Computer Aided Instructional (CAI) tool for teaching discrete math to the Naval Academy and the

  18. Sexual life and sexual wellness in individuals with complete androgen insensitivity syndrome (CAIS) and Mayer-Rokitansky-Küster-Hauser Syndrome (MRKHS).

    Science.gov (United States)

    Fliegner, Maike; Krupp, Kerstin; Brunner, Franziska; Rall, Katharina; Brucker, Sara Y; Briken, Peer; Richter-Appelt, Hertha

    2014-03-01

    Sexual wellness depends on a person's physical and psychological constitution. Complete Androgen Insensitivity Syndrome (CAIS) and Mayer-Rokitansky-Küster-Hauser Syndrome (MRKHS) can compromise sexual well-being. To compare sexual well-being in CAIS and MRKHS using multiple measures: To assess sexual problems and perceived distress. To gain insight into participants' feelings of inadequacy in social and sexual situations, level of self-esteem and depression. To determine how these psychological factors relate to sexual (dys)function. To uncover what participants see as the source of their sexual problems. Data were collected using a paper-and-pencil questionnaire. Eleven individuals with CAIS and 49 with MRKHS with/without neovagina treatment were included. Rates of sexual dysfunctions, overall sexual function, feelings of inadequacy in social and sexual situations, self-esteem and depression scores were calculated. Categorizations were used to identify critical cases. Correlations between psychological variables and sexual function were computed. Sexually active subjects were compared with sexually not active participants. A qualitative content analysis was carried out to explore causes of sexual problems. An extended list of sexual problems based on the Diagnostic and Statistical Manual of Mental Disorders, 4th ed., text revision, by the American Psychiatric Association and related distress. Female Sexual Function Index (FSFI), German Questionnaire on Feelings of Inadequacy in Social and Sexual Situations (FUSS social scale, FUSS sexual scale), Rosenberg Self-Esteem Scale (RSE), Brief Symptom Inventory (BSI) subscale depression. Open question on alleged causes of sexual problems. The results point to a far-reaching lack of sexual confidence and sexual satisfaction in CAIS. In MRKHS apprehension in sexual situations is a source of distress, but sexual problems seem to be more focused on issues of vaginal functioning. MRKHS women report being satisfied with their

  19. A companion agent for automated training systems

    NARCIS (Netherlands)

    Buiël, E.F.T.; Lubbers, J.

    2007-01-01

    TNO Defence, Security & Safety has a long history of applied research in the area of automated simulator-based training by means of Computer-Assisted Instruction (CAI). Traditionally, a CAI system does not enable a true dialogue between the learner and the virtual instructor. Most frequently, the

  20. Electrophysiology Catheter-Facilitated coronary sinus cannulation and implantation of cardiac resynchronization therapy systems

    Directory of Open Access Journals (Sweden)

    Antonis S. Manolis, MD, FESC, FACC, FHRS

    2018-01-01

    Full Text Available Background: Cardiac resynchronization therapy (CRT device implantation is hampered by difficult placement of the left ventricular (LV lead. We have routinely used a steerable electrophysiology catheter to guide coronary sinus (CS cannulation and facilitate LV lead positioning. The aim of this prospective study is to present our results with this approach in 138 consecutive patients receiving a CRT device over 10 years. Methods: The study included 120 men and 18 women, aged 64.8±11.4 years, with coronary disease (n=63, cardiomyopathy (n=72, or other disease (n=3, and mean ejection fraction of 24.5±4.5%. Devices were implanted for refractory heart failure and dyssynchrony, all but 2 in the presence of left bundle branch block. Implanted devices included biventricular pacemakers (CRT-P (n=33 and cardioverter defibrillators (CRT-D (n=105. Results: Using the electrophysiology catheter, the CS could be engaged in 134 (97.1% patients. In 4 patients failing CS cannulation, a dual-chamber device was implanted in 2, and bifocal right ventricular pacing was effected in 2. Bifocal (n=2 or conventional (n=1 systems were implanted in another 3 patients, in whom the LV lead got dislodged (n=2 or removed because of local dissection (n=1. Thus, finally, a CRT system was successfully established in 131 (94.9% patients. There were 3 patients with CS dissection, of whom 1 was complicated by cardiac tamponade managed with pericardiocentesis. There were no perioperative deaths. During follow-up (31.0±21.2 months, clinical improvement was reported by 108 (82.4% patients. Conclusion: Routine use of an electrophysiology catheter greatly facilitated CS cannulation and successful LV lead placement in ∼95% of patients undergoing CRT system implantation. Keywords: heart failure, cardiac resynchronization therapy, implantable cardioverter defibrillator, coronary sinus, left ventricular lead

  1. Bioelectric analyses of an osseointegrated intelligent implant design system for amputees.

    Science.gov (United States)

    Isaacson, Brad M; Stinstra, Jeroen G; MacLeod, Rob S; Webster, Joseph B; Beck, James P; Bloebaum, Roy D

    2009-07-15

    The projected number of American amputees is expected to rise to 3.6 million by 2050. Many of these individuals depend on artificial limbs to perform routine activities, but prosthetic suspensions using traditional socket technology can prove to be cumbersome and uncomfortable for a person with limb loss. Moreover, for those with high proximal amputations, limited residual limb length may prevent exoprosthesis attachment all together. Osseointegrated implant technology is a novel operative procedure which allows firm skeletal attachment between the host bone and an implant. Preliminary results in European amputees with osseointegrated implants have shown improved clinical outcomes by allowing direct transfer of loads to the bone-implant interface. Despite the apparent advantages of osseointegration over socket technology, the current rehabilitation procedures require long periods of restrictive load bearing prior which may be reduced with expedited skeletal attachment via electrical stimulation. The goal of the osseointegrated intelligent implant design (OIID) system is to make the implant part of an electrical system to accelerate skeletal attachment and help prevent periprosthetic infection. To determine optimal electrode size and placement, we initiated proof of concept with computational modeling of the electric fields and current densities that arise during electrical stimulation of amputee residual limbs. In order to provide insure patient safety, subjects with retrospective computed tomography scans were selected and three dimensional reconstructions were created using customized software programs to ensure anatomical accuracy (Seg3D and SCIRun) in an IRB and HIPAA approved study. These software packages supported the development of patient specific models and allowed for interactive manipulation of electrode position and size. Preliminary results indicate that electric fields and current densities can be generated at the implant interface to achieve the

  2. Adaptation of an aerosol retrieval algorithm using multi-wavelength and multi-pixel information of satellites (MWPM) to GOSAT/TANSO-CAI

    Science.gov (United States)

    Hashimoto, M.; Takenaka, H.; Higurashi, A.; Nakajima, T.

    2017-12-01

    Aerosol in the atmosphere is an important constituent for determining the earth's radiation budget, so the accurate aerosol retrievals from satellite is useful. We have developed a satellite remote sensing algorithm to retrieve the aerosol optical properties using multi-wavelength and multi-pixel information of satellite imagers (MWPM). The method simultaneously derives aerosol optical properties, such as aerosol optical thickness (AOT), single scattering albedo (SSA) and aerosol size information, by using spatial difference of wavelegths (multi-wavelength) and surface reflectances (multi-pixel). The method is useful for aerosol retrieval over spatially heterogeneous surface like an urban region. In this algorithm, the inversion method is a combination of an optimal method and smoothing constraint for the state vector. Furthermore, this method has been combined with the direct radiation transfer calculation (RTM) numerically solved by each iteration step of the non-linear inverse problem, without using look up table (LUT) with several constraints. However, it takes too much computation time. To accelerate the calculation time, we replaced the RTM with an accelerated RTM solver learned by neural network-based method, EXAM (Takenaka et al., 2011), using Rster code. And then, the calculation time was shorternd to about one thouthandth. We applyed MWPM combined with EXAM to GOSAT/TANSO-CAI (Cloud and Aerosol Imager). CAI is a supplement sensor of TANSO-FTS, dedicated to measure cloud and aerosol properties. CAI has four bands, 380, 674, 870 and 1600 nm, and observes in 500 meters resolution for band1, band2 and band3, and 1.5 km for band4. Retrieved parameters are aerosol optical properties, such as aerosol optical thickness (AOT) of fine and coarse mode particles at a wavelenth of 500nm, a volume soot fraction in fine mode particles, and ground surface albedo of each observed wavelength by combining a minimum reflectance method and Fukuda et al. (2013). We will show

  3. Accuracy of various impression materials and methods for two implant systems: An effect size study.

    Science.gov (United States)

    Schmidt, Alexander; Häussling, Teresa; Rehmann, Peter; Schaaf, Heidrun; Wöstmann, Bernd

    2018-04-01

    An accurate impression is required for implant treatment. The aim of this in-vitro study was to determine the effect size of the impression material/method, implant system and implant angulation on impression transfer precision. An upper jaw model with three BEGO and three Straumann implants (angulations 0°, 15°, 20°) in the left and right maxilla was used as a reference model. One polyether (Impregum Penta) and two polyvinyl siloxanes (Flexitime Monophase/Aquasil Ultra Monophase) were examined with two impression techniques (open and closed tray). A total of 60 impressions were made. A coordinate measurement machine was used to measure the target variables for 3D-shift, implant axis inclination and implant axis rotation. All the data were subjected to a four-way ANOVA. The effect size (partial eta-squared [η 2 P ]) was reported. The impression material had a significant influence on the 3D shift and the implant axis inclination deviation (p-values=.000), and both factors had very large effect sizes (3D-shift [η 2 P ]=.599; implant axis inclination [η 2 P ]=.298). Impressions made with polyvinyl siloxane exhibited the highest transfer precision. When the angulation of the implants was larger, more deviations occurred for the implant axis rotational deviation. The implant systems and impression methods showed partially significant variations (p-values=.001-.639) but only very small effect sizes (η 2 P =.001-.031). The impression material had the greatest effect size on accuracy in terms of the 3D shift and the implant axis inclination. For multiunit restorations with disparallel implants, polyvinyl siloxane materials should be considered. In addition, the effect size of a multivariate investigation should be reported. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  4. Recent progress in the development of Terumo implantable left ventricular assist system.

    Science.gov (United States)

    Nojiri, C; Kijima, T; Maekawa, J; Horiuchi, K; Kido, T; Sugiyama, T; Mori, T; Sugiura, N; Asada, T; Shimane, H; Ozaki, T; Suzuki, M; Akamatsu, T; Akutsu, T

    1999-01-01

    The research group of the Terumo Corporation, the NTN Corporation, and Setsunan University (T. Akamatsu) has been developing an implantable left ventricular assist system (ILVAS) featuring a centrifugal blood pump with a magnetically suspended impeller (MSCP). The impeller of the MSCP is suspended by a magnetic bearing, providing contact-free rotation of the impeller inside the pump housing. Thus the MSCP is expected to provide years of long-term durability. Ex vivo chronic sheep experiments using the extracorporeal model (Model I) demonstrated long-term durability, nonthrombogenicity, and a low hemolysis rate (plasma free Hb model (Model II; 196 ml, 400 g) was evaluated ex vivo in 2 sheep and intrathoracically implanted in a small sheep (45 kg). These experiments were terminated at 70, 79, and 17 days, respectively, because of blood leakage through the connector system within the housing of Model II. There was no thrombus formation on the retrieved pump surfaces. A new connector system was introduced to the Model II pump (modified Model II), and the pump was intrathoracically implanted in a sheep. Pump flow rate was maintained at 3-7 L/min at 1700-1800 rpm. The temperature elevation on the surfaces of the motor and the electromagnet inside the pump casing was kept less than 6 degrees C. The temperature of the tissue adjacent to the pump casing became normal 10 days postoperatively. The sheep survived for more than 5 months without any sign of mechanical failure or thromboembolic complication. In vitro real-time endurance tests of motor bearings made of stainless steel and silicone nitride have been conducted for more than 1 year without any sign of bearing wear. The next prototype system (Model III), with an implantable controller and a new MSCP with reduced input power, has been developed with a view toward a totally implantable LVAS.

  5. Ultrasound guided implantation of chest port systems via the lateral subclavian vein

    International Nuclear Information System (INIS)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K.; Warm, M.; Reiser, M.; Toex, U.

    2006-01-01

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  6. Mutual-Information-Based Incremental Relaying Communications for Wireless Biomedical Implant Systems

    Directory of Open Access Journals (Sweden)

    Yangzhe Liao

    2018-02-01

    Full Text Available Network lifetime maximization of wireless biomedical implant systems is one of the major research challenges of wireless body area networks (WBANs. In this paper, a mutual information (MI-based incremental relaying communication protocol is presented where several on-body relay nodes and one coordinator are attached to the clothes of a patient. Firstly, a comprehensive analysis of a system model is investigated in terms of channel path loss, energy consumption, and the outage probability from the network perspective. Secondly, only when the MI value becomes smaller than the predetermined threshold is data transmission allowed. The communication path selection can be either from the implanted sensor to the on-body relay then forwards to the coordinator or from the implanted sensor to the coordinator directly, depending on the communication distance. Moreover, mathematical models of quality of service (QoS metrics are derived along with the related subjective functions. The results show that the MI-based incremental relaying technique achieves better performance in comparison to our previous proposed protocol techniques regarding several selected performance metrics. The outcome of this paper can be applied to intra-body continuous physiological signal monitoring, artificial biofeedback-oriented WBANs, and telemedicine system design.

  7. Approaches and Challenges of Engineering Implantable Microelectromechanical Systems (MEMS Drug Delivery Systems for in Vitro and in Vivo Applications

    Directory of Open Access Journals (Sweden)

    Ken-Tye Yong

    2012-11-01

    Full Text Available Despite the advancements made in drug delivery systems over the years, many challenges remain in drug delivery systems for treating chronic diseases at the personalized medicine level. The current urgent need is to develop novel strategies for targeted therapy of chronic diseases. Due to their unique properties, microelectromechanical systems (MEMS technology has been recently engineered as implantable drug delivery systems for disease therapy. This review examines the challenges faced in implementing implantable MEMS drug delivery systems in vivo and the solutions available to overcome these challenges.

  8. The Syed temporary interstitial iridium gynaecological implant: an inverse planning system

    International Nuclear Information System (INIS)

    Fung, Albert Y.C.

    2002-01-01

    Patients with advanced gynaecological cancer are often treated with a temporary interstitial implant using the Syed template and Ir-192 ribbons at the Memorial Sloan-Kettering Cancer Center. Urgency in planning is great. We created a computerized inverse planning system for the Syed temporary gynaecological implant, which optimized the ribbon strengths a few seconds after catheter digitization. Inverse planning was achieved with simulated annealing. We discovered that hand-drawn target volumes had drawbacks; hence instead of producing a grid of points based on target volume, the optimization points were generated directly from the catheter positions without requiring an explicit target volume. Since all seeds in the same ribbon had the same strength, the minimum doses were located at both ends of the implant. Optimization points generated at both ends ensured coverage of the whole implant. Inverse planning took only a few seconds, and generated plans that provide a good starting point for manual improvement. (author)

  9. A Comparison of Clinical Outcomes with Regular- and Low-Profile Totally Implanted Central Venous Port Systems

    International Nuclear Information System (INIS)

    Teichgraeber, Ulf Karl-Martin; Steitparth, Florian; Cho, Chie Hee; Benter, Thomas; Gebauer, Bernhard

    2009-01-01

    The purpose of this study was to evaluate whether low-profile totally implanted central venous port systems can reduce the late complication of skin perforation. Forty patients (age, 57 ± 13 years; 22 females, 18 males) were randomized for the implantation of a low-profile port system, and another 40 patients (age, 61 ± 14 years; 24 females, 16 males) received a regular port system as control group. Indications for port catheter implantation were malignant disease requiring chemotherapy. All port implantations were performed in the angiography suite using sonographically guided central venous puncture and fluoroscopic guidance of the catheter placement. Procedure time, number of complications (procedure-related immediate, early, and late complications), and number of explantations were assessed. Follow-up was performed for 6 months. All port implantations were successfully completed in both study groups. There were two incidents of skin perforation observed in the control group. One skin perforation occurred 13 weeks and the other 16 weeks after port implantation (incidence, 5%) in patients with regular-profile port systems. Two infections were observed, one port infection in each study group. Both infections were characterized as catheter-related infections (infection rate: 0.15 catheter-related infections per 1000 catheter days). In conclusion, low-profile port systems can be placed as safely as traditional chest ports and reduce the risk of developing skin perforations, which occurs when the port system is too tight within the port pocket.

  10. Patient satisfaction and dissatisfaction with mandibular two-implant overdentures using different attachment systems: 5-year outcomes.

    Science.gov (United States)

    Al-Zubeidi, Mohammed I; Alsabeeha, Nabeel H M; Thomson, W Murray; Payne, Alan G T

    2012-10-01

    Different attachment systems for mandibular two-implant overdentures could influence levels of patient satisfaction. Positive consensus of the majority of patients being satisfied does not preclude the possibility of dissatisfaction for some. To evaluate patient satisfaction and dissatisfaction before and after 5 years of wearing mandibular two implant overdentures using different attachment systems ; to determine the prognostic relevance of pretreatment complete denture complaints to treatment outcomes. A total of 106 edentulous participants enrolled in a clinical trial completed a preliminary self-report inventory of their original complete denture complaints.New complete maxillary dentures and mandibular two-implant overdentures were provided to each participant using one of six different attachment systems. Patient satisfaction was determined at pretreatment; at baseline with mandibular two-implant overdenture insertion; and then annually for 5 years, using visual analogue and Likert-type scales. Patient satisfaction with mandibular two-implant overdentures showed significant changes pre- to posttreatment(baseline) in all domains, but these were significant immediately and maintained without further significance for 5 years, other than pain with the overdenture. After 5 years, no significant differences were observed with all the attachment systems. Highly significant differences were found with some social and psychological aspects by the fifth year compared to baseline. Diagnostic and prognostic indicators from a pretreatment inventory identified 12 participants (13.5%) who were dissatisfied. These indicators revealed a maladaptive predisposition to mandibular two-implant overdentures. The provision of mandibular two-implant overdentures will, in the majority of patients, significantly enhance levels of patient satisfaction for 5 years, as compared to complete mandibular dentures, regardless of the attachment system. Careful evaluation of pretreatment

  11. Bandwidth Efficient Overlapped FSK Coded Secure Command Transmission for Medical Implant Communication Systems

    Directory of Open Access Journals (Sweden)

    Selman KULAÇ

    2018-06-01

    Full Text Available Nowadays, wireless communication systems are exploited in most health care systems. Implantable Medical Systems (IMS also have wireless communication capability. However, it is very important that secure wireless communication should be provided in terms of both patient rights and patient health. Therefore, wireless transmission systems of IMS should also be robust against to eavesdroppers and adversaries. In this study, a specific overlapped and coded frequency shift keying (FSK modulation technique is developed and security containing with low complexity is provided by this proposed technique. The developed method is suitable for wireless implantable medical systems since it provides low complexity and security as well as bandwidth efficiency.

  12. From Corporate Social Responsibility, through Entrepreneurial Orientation, to Knowledge Sharing: A Study in Cai Luong (Renovated Theatre) Theatre Companies

    Science.gov (United States)

    Tuan, Luu Trong

    2015-01-01

    Purpose: This paper aims to examine the role of antecedents such as corporate social responsibility (CSR) and entrepreneurial orientation in the chain effect to knowledge sharing among members of Cai Luong theatre companies in the Vietnamese context. Knowledge sharing contributes to the depth of the knowledge pool of both the individuals and the…

  13. Crystal Growth and Scintillation Properties of Eu2+ doped Cs4CaI6 and Cs4SrI6

    Science.gov (United States)

    Stand, L.; Zhuravleva, M.; Chakoumakos, B.; Johnson, J.; Loyd, M.; Wu, Y.; Koschan, M.; Melcher, C. L.

    2018-03-01

    In this work we present the crystal growth and scintillation properties of two new ternarymetal halide scintillators activated with divalent europium, Cs4CaI6 and Cs4SrI6. Single crystals of each compound were grown in evacuated quartz ampoules via the vertical Bridgman technique using a two-zone transparent furnace. Single crystal X-ray diffraction experiments showed that both crystals have a trigonal (R-3c) structure, with a density of 3.99 g/cm3 and 4.03 g/cm3. The radioluminescence and photoluminescence measurements showed typical luminescence properties due to the 5d-4f radiative transitions in Eu2+. At this early stage of development Cs4SrI6:Eu and Cs4CaI6:Eu have shown very promising scintillation properties, with light yields and energy resolutions of 62,300 ph/MeV and 3.3%, and 51,800 photons/MeV and 3.6% at 662 keV, respectively.

  14. Computer aided information system for a PWR

    International Nuclear Information System (INIS)

    Vaidian, T.A.; Karmakar, G.; Rajagopal, R.; Shankar, V.; Patil, R.K.

    1994-01-01

    The computer aided information system (CAIS) is designed with a view to improve the performance of the operator. CAIS assists the plant operator in an advisory and support role, thereby reducing the workload level and potential human errors. The CAIS as explained here has been designed for a PWR type KLT- 40 used in Floating Nuclear Power Stations (FNPS). However the underlying philosophy evolved in designing the CAIS can be suitably adopted for other type of nuclear power plants too (BWR, PHWR). Operator information is divided into three broad categories: a) continuously available information b) automatically available information and c) on demand information. Two in number touch screens are provided on the main control panel. One is earmarked for continuously available information and the other is dedicated for automatically available information. Both the screens can be used at the operator's discretion for on-demand information. Automatically available information screen overrides the on-demand information screens. In addition to the above, CAIS has the features of event sequence recording, disturbance recording and information documentation. CAIS design ensures that the operator is not overburdened with excess and unnecessary information, but at the same time adequate and well formatted information is available. (author). 5 refs., 4 figs

  15. 3-Coil resonance-based wireless power transfer system for implantable electronic

    KAUST Repository

    Yi, Ying; Buttner, Ulrich; Fan, Yiqiang; Foulds, Ian G.

    2013-01-01

    This paper presents a 3-coil resonance-based wireless power transfer (R-WPT) system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. A theoretical analysis and experimental measurements in terms of quality factor Q and power transfer efficiency (PTE), was done. Our proposed 3-coil scheme can achieve a high PTE with a resonance frequency of 2.46 MHz over a transfer distance of up to 30 mm, by using two 15-mm radius implant coils. The achieved experimental PTE is more than 85%at a 5 mm separation distance, and about 50% PTE at a distance of 20 mm. © 2013 IEEE.

  16. 3-Coil resonance-based wireless power transfer system for implantable electronic

    KAUST Repository

    Yi, Ying

    2013-05-01

    This paper presents a 3-coil resonance-based wireless power transfer (R-WPT) system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. A theoretical analysis and experimental measurements in terms of quality factor Q and power transfer efficiency (PTE), was done. Our proposed 3-coil scheme can achieve a high PTE with a resonance frequency of 2.46 MHz over a transfer distance of up to 30 mm, by using two 15-mm radius implant coils. The achieved experimental PTE is more than 85%at a 5 mm separation distance, and about 50% PTE at a distance of 20 mm. © 2013 IEEE.

  17. Comparative evaluation of the effectiveness of the implantation in the lateral part of the mandible between short tissue level (TE) and bone level (BL) implant systems.

    Science.gov (United States)

    Hadzik, Jakub; Botzenhart, Ute; Krawiec, Maciej; Gedrange, Tomasz; Heinemann, Friedhelm; Vegh, Andras; Dominiak, Marzena

    2017-09-01

    Short dental implants can be an alternative method of treatment to a vertical bone augmentation procedure at sites of reduced alveolar height. However, for successful treatment, an implant system that causes a minimal marginal bone loss (MBL) should be taken into consideration. The aim of the study has been to evaluate implantation effectiveness for bone level and tissue level short implants provided in lateral aspects of partially edentulous mandible and limited alveolar ridge height. The MBL and primary as well as secondary implant stability were determined in the study. Patients were randomly divided into two groups according to the method of treatment provided. Sixteen short Bone Level Implants (OsseoSpeed TX, Astra tech) and 16 short Tissue Level Implants (RN SLActive ® , Straumann) were successfully placed in the edentulous part of the mandible. The determination of the marginal bone level was based on radiographic evaluation after 12 and 36 weeks. Implant stability was measured immediately after insertion and after 12 weeks. The marginal bone level of Bone Level Implants was significantly lower compared to Tissue Level Implants. Furthermore, the Bone Level Implants had greater primary and secondary stability in comparison with Tissue Level Implants (Primary: 77.8 ISQ versus 66.5 ISQ; Secondary: 78.9 ISQ versus 73.9 ISQ, respectively). Since short Bone Level Implants showed a significantly decreased MBL 12 and 36 weeks after implantation as well as better results for the primary stability compared to Tissue Level Implants, they should preferentially be used for this mentioned indication. Copyright © 2017 Elsevier GmbH. All rights reserved.

  18. Retention systems for extraoral maxillofacial prosthetic implants: a critical review.

    Science.gov (United States)

    Cobein, M V; Coto, N P; Crivello Junior, O; Lemos, J B D; Vieira, L M; Pimentel, M L; Byrne, H J; Dias, R B

    2017-10-01

    We describe the techniques available for retention of implant-supported prostheses: bar-clips, O-rings, and magnets. We present reported preferences and, although this is limited by the heterogeneity of methods used and patients studied, we hope we have identified the best retention systems for maxillofacial prosthetic implants. If practitioners know the advantages and disadvantages of each system, they can choose the most natural and comfortable prosthesis. We searched the PubMed and Scopus databases, and restricted our search to papers published 2001-13. MeSH terms used were Maxillofacial prosthesis and Craniofacial prosthesis OR Craniofacial prostheses. We found a total of 2630 papers, and after duplicates had been removed we analysed the rest and found 25 papers for review. Of these, 12 were excluded because they were case reports or non-systematic reviews. Of the remaining 13, 10 described group analyses and seemed appropriate to find practitioner's choices, as cited in the abstract (n=1611 prostheses). Three papers did not mention the type of prosthetic connection used, so were excluded. The most popular choices for different conditions were analysed, though the sites and retention systems were not specified in all 10 papers. The bar-clip system was the most used in auricular (6/10 papers) and nasal prostheses (4/10). For the orbital region, 6/10 favoured magnets. Non-osseointegrated mechanical or adhesive retention techniques are the least expensive and have no contraindications. When osseointegrated implants are possible, each facial region has a favoured system. The choice of system is influenced by two factors: standard practice and the abilities of the maxillofacial surgeon and maxillofacial prosthetist. Copyright © 2017 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Intraoperative implant rod three-dimensional geometry measured by dual camera system during scoliosis surgery.

    Science.gov (United States)

    Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu

    2016-05-12

    Treatment for severe scoliosis is usually attained when the scoliotic spine is deformed and fixed by implant rods. Investigation of the intraoperative changes of implant rod shape in three-dimensions is necessary to understand the biomechanics of scoliosis correction, establish consensus of the treatment, and achieve the optimal outcome. The objective of this study was to measure the intraoperative three-dimensional geometry and deformation of implant rod during scoliosis corrective surgery.A pair of images was obtained intraoperatively by the dual camera system before rotation and after rotation of rods during scoliosis surgery. The three-dimensional implant rod geometry before implantation was measured directly by the surgeon and after surgery using a CT scanner. The images of rods were reconstructed in three-dimensions using quintic polynomial functions. The implant rod deformation was evaluated using the angle between the two three-dimensional tangent vectors measured at the ends of the implant rod.The implant rods at the concave side were significantly deformed during surgery. The highest rod deformation was found after the rotation of rods. The implant curvature regained after the surgical treatment.Careful intraoperative rod maneuver is important to achieve a safe clinical outcome because the intraoperative forces could be higher than the postoperative forces. Continuous scoliosis correction was observed as indicated by the regain of the implant rod curvature after surgery.

  20. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  1. Two years since SSAMS: Status of {sup 14}C AMS at CAIS

    Energy Technology Data Exchange (ETDEWEB)

    Ravi Prasad, G.V.; Cherkinsky, Alexander; Culp, Randy A.; Dvoracek, Doug K.

    2015-10-15

    The NEC 250 kV single stage AMS accelerator (SSAMS) was installed two years ago at the Center for Applied Isotope Studies (CAIS), University of Georgia. The accelerator is primarily being used for radiocarbon measurements to test the authenticity of natural and bio-based samples while all other samples such as geological, atmospheric, marine and archaeological. are run on the 500 kV, NEC 1.5SDH-1 model tandem accelerator, which has been operating since 2001. The data obtained over a six months period for OXI, OXII, ANU sucrose and FIRI-D are discussed. The mean value of ANU sucrose observed to be slightly lower than the consensus value. The processed blanks on SSAMS produce lower apparent age compared to the tandem accelerator as expected.

  2. STAF: A Powerful and Sophisticated CAI System.

    Science.gov (United States)

    Loach, Ken

    1982-01-01

    Describes the STAF (Science Teacher's Authoring Facility) computer-assisted instruction system developed at Leeds University (England), focusing on STAF language and major program features. Although programs for the system emphasize physical chemistry and organic spectroscopy, the system and language are general purpose and can be used in any…

  3. Ultrasound guided implantation of chest port systems via the lateral subclavian vein; Die sonographisch gezielte Implantation von Portkathetersystemen ueber die laterale Vena subclavia

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K. [Inst. fuer Radiologische Diagnostik, Univ. zu Koeln (Germany); Warm, M. [Gynaekologie, Univ. zu Koeln (Germany); Reiser, M. [Medizinische Klinik I, Univ. zu Koeln (Germany); Toex, U. [Medizinische Klinik IV, Univ. zu Koeln (Germany)

    2006-03-15

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  4. The computer aided education and training system for accident management

    International Nuclear Information System (INIS)

    Yoneyama, Mitsuru; Kubota, Ryuji; Fujiwara, Tadashi; Sakuma, Hitoshi

    1999-01-01

    The education and training system for Accident Management was developed by the Japanese BWR group and Hitachi Ltd. The education and training system is composed of two systems. One is computer aided instruction (CAI) education system and the education and training system with computer simulations. Both systems are designed to be executed on personal computers. The outlines of the CAI education system and the education and training system with simulator are reported below. These systems provides plant operators and technical support center staff with the effective education and training for accident management. (author)

  5. An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode.

    Science.gov (United States)

    Shon, Ahnsei; Chu, Jun-Uk; Jung, Jiuk; Kim, Hyungmin; Youn, Inchan

    2017-12-21

    Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.

  6. An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode

    Directory of Open Access Journals (Sweden)

    Ahnsei Shon

    2017-12-01

    Full Text Available Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC-compliant power transmission circuit, a medical implant communication service (MICS-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.

  7. Systemic Assessment of Patients Undergoing Dental Implant Surgeries: A Trans- and Post-operative Analysis.

    Science.gov (United States)

    Byakodi, Sanjay; Kumar, Sachin; Reddy, Rajesh Kumar; Kumar, Vipin; Sepolia, Shipra; Gupta, Shivangi; Singh, Harkanwal Preet

    2017-01-01

    Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI) questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1) absolutely not, (2) slightly, (3) somewhat, or (4) very much. All the results were recorded and statistical analyzed by SPSS software. Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality ( n = 38). Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla ( P < 0.001). The difference of average STAI-State subscore before and after the surgery was statistically significant ( P < 0.05; significant). Mandibular dental implants show more clamping (torque) than maxillary dental implants.

  8. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    Directory of Open Access Journals (Sweden)

    Sanjay Byakodi

    2017-01-01

    Full Text Available Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1 absolutely not, (2 slightly, (3 somewhat, or (4 very much. All the results were recorded and statistical analyzed by SPSS software. Results: Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality (n = 38. Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla (P < 0.001. The difference of average STAI-State subscore before and after the surgery was statistically significant (P < 0.05; significant. Conclusion: Mandibular dental implants show more clamping (torque than maxillary

  9. The KineSpring® Knee Implant System: an implantable joint-unloading prosthesis for treatment of medial knee osteoarthritis

    Directory of Open Access Journals (Sweden)

    Clifford AG

    2013-05-01

    Full Text Available Anton G Clifford,1 Stefan M Gabriel,1 Mary O’Connell,1 David Lowe,1 Larry E Miller,2,3 Jon E Block31Moximed, Inc, Hayward, CA, USA; 2Miller Scientific Consulting, Inc, Arden, NC, USA; 3The Jon Block Group, San Francisco, CA, USAAbstract: Symptomatic medial compartment knee osteoarthritis (OA is the leading cause of musculoskeletal pain and disability in adults. Therapies intended to unload the medial knee compartment have yielded unsatisfactory results due to low patient compliance with conservative treatments and high complication rates with surgical options. There is no widely available joint-unloading treatment for medial knee OA that offers clinically important symptom alleviation, low complication risk, and high patient acceptance. The KineSpring® Knee Implant System (Moximed, Inc, Hayward, CA, USA is a first-of-its-kind, implantable, extra-articular, extra-capsular prosthesis intended to alleviate knee OA-related symptoms by reducing medial knee compartment loading while overcoming the limitations of traditional joint-unloading therapies. Preclinical and clinical studies have demonstrated excellent prosthesis durability, substantial reductions in medial compartment and total joint loads, and clinically important improvements in OA-related pain and function. The purpose of this report is to describe the KineSpring System, including implant characteristics, principles of operation, indications for use, patient selection criteria, surgical technique, postoperative care, preclinical testing, and clinical experience. The KineSpring System has potential to bridge the gap between ineffective conservative treatments and irreversible surgical interventions for medial compartment knee OA.Keywords: KineSpring, knee, medial, osteoarthritis, prosthesis

  10. A wireless power transmission system for implantable devices in freely moving rodents.

    Science.gov (United States)

    Eom, Kyungsik; Jeong, Joonsoo; Lee, Tae Hyung; Kim, Jinhyung; Kim, Junghoon; Lee, Sung Eun; Kim, Sung June

    2014-08-01

    Reliable wireless power delivery for implantable devices in animals is highly desired for safe and effective experimental use. Batteries require frequent replacement; wired connections are inconvenient and unsafe, and short-distance inductive coupling requires the attachment of an exterior transmitter to the animal's body. In this article, we propose a solution by which animals with implantable devices can move freely without attachments. Power is transmitted using coils attached to the animal's cage and is received by a receiver coil implanted in the animal. For a three-dimensionally uniform delivery of power, we designed a columnar dual-transmitter coil configuration. A resonator-based inductive link was adopted for efficient long-range power delivery, and we used a novel biocompatible liquid crystal polymer substrate as the implantable receiver device. Using this wireless power delivery system, we obtain an average power transfer efficiency of 15.2% (minimum efficiency of 10% and a standard deviation of 2.6) within a cage of 15×20×15 cm3.

  11. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. 182Hf-182W age dating of a 26Al-poor inclusion and implications for the origin of short-lived radioisotopes in the early Solar System

    DEFF Research Database (Denmark)

    Holst, Jesper Christian; Olsen, Mia Bjørg Stolberg; Paton, Chad

    2013-01-01

    provide a unique window into the earliest Solar System, including the origin of short-lived radioisotopes. However, their chronology is unknown. Using the 182Hf–182W chronometer, we show that a FUN CAI recording a condensation origin from a solar gas formed coevally with canonical CAIs, but with 26Al/27Al......Refractory inclusions [calcium–aluminum-rich inclusions, (CAIs)] represent the oldest Solar System solids and provide information regarding the formation of the Sun and its protoplanetary disk. CAIs contain evidence of now extinct short-lived radioisotopes (e.g., 26Al, 41Ca, and 182Hf) synthesized...... in one or multiple stars and added to the protosolar molecular cloud before or during its collapse. Understanding how and when short-lived radioisotopes were added to the Solar System is necessary to assess their validity as chronometers and constrain the birthplace of the Sun. Whereas most CAIs formed...

  13. An image guidance system for positioning robotic cochlear implant insertion tools

    Science.gov (United States)

    Bruns, Trevor L.; Webster, Robert J.

    2017-03-01

    Cochlear implants must be inserted carefully to avoid damaging the delicate anatomical structures of the inner ear. This has motivated several approaches to improve the safety and efficacy of electrode array insertion by automating the process with specialized robotic or manual insertion tools. When such tools are used, they must be positioned at the entry point to the cochlea and aligned with the desired entry vector. This paper presents an image guidance system capable of accurately positioning a cochlear implant insertion tool. An optical tracking system localizes the insertion tool in physical space while a graphical user interface incorporates this with patient- specific anatomical data to provide error information to the surgeon in real-time. Guided by this interface, novice users successfully aligned the tool with an mean accuracy of 0.31 mm.

  14. Successful Rehabilitation of Partial Edentulous Maxilla and Mandible with New Type of Implants: Molecular Precision Implants

    Directory of Open Access Journals (Sweden)

    Matteo Danza

    2014-01-01

    Full Text Available The extraction of teeth results in rapid bone resorption both vertically and horizontally in the first month. The loss of alveolar ridge reduces the chance of implant rehabilitation. Atraumatic extraction, implant placement in extraction socket, and an immediate prosthesis have been proposed as alternative therapies to maintain the volume and contours tissue and reduce time and cost of treatment. The immediate load of implants is a universally practiced procedure; nevertheless a successful procedure requires expertise in both the clinical and the reconstructive stages using a solid implant system. Excellent primary stability and high bone-implant contact are only minimal requirements for any type of implant procedure. In this paper we present a case report using a new type of implants. The new type of implants, due to its sophisticated control system of production, provides to the implantologist a safe and reliable implant, with a macromorphology designed to ensure a close contact with the surrounding bone.

  15. In-vitro characterization of a cochlear implant system for recording of evoked compound action potentials

    Science.gov (United States)

    2012-01-01

    Background Modern cochlear implants have integrated recording systems for measuring electrically evoked compound action potentials of the auditory nerve. The characterization of such recording systems is important for establishing a reliable basis for the interpretation of signals acquired in vivo. In this study we investigated the characteristics of the recording system integrated into the MED-EL PULSARCI100 cochlear implant, especially its linearity and resolution, in order to develop a mathematical model describing the recording system. Methods In-vitro setup: The cochlear implant, including all attached electrodes, was fixed in a tank of physiologic saline solution. Sinusoidal signals of the same frequency but with different amplitudes were delivered via a signal generator for measuring and recording on a single electrode. Computer simulations: A basic mathematical model including the main elements of the recording system, i.e. amplification and digitalization stage, was developed. For this, digital output for sinusoidal input signals of different amplitudes were calculated using in-vitro recordings as reference. Results Using an averaging of 100 measurements the recording system behaved linearly down to approximately -60 dB of the input signal range. Using the same method, a system resolution of 10 μV was determined for sinusoidal signals. The simulation results were in very good agreement with the results obtained from in-vitro experiments. Conclusions The recording system implemented in the MED-EL PULSARCI100 cochlear implant for measuring the evoked compound action potential of the auditory nerve operates reliably. The developed mathematical model provides a good approximation of the recording system. PMID:22531599

  16. An Implantable Cardiovascular Pressure Monitoring System with On-Chip Antenna and RF Energy Harvesting

    Directory of Open Access Journals (Sweden)

    Yu-Chun Liu

    2015-08-01

    Full Text Available An implantable wireless system with on-chip antenna for cardiovascular pressure monitor is studied. The implantable device is operated in a batteryless manner, powered by an external radio frequency (RF power source. The received RF power level can be sensed and wirelessly transmitted along with blood pressure signal for feedback control of the external RF power. The integrated electronic system, consisting of a capacitance-to-voltage converter, an adaptive RF powering system, an RF transmitter and digital control circuitry, is simulated using a TSMC 0.18 μm CMOS technology. The implanted RF transmitter circuit is combined with a low power voltage-controlled oscillator resonating at 5.8 GHz and a power amplifier. For the design, the simulation model is setup using ADS and HFSS software. The dimension of the antenna is 1 × 0.6 × 4.8 mm3 with a 1 × 0.6 mm2 on-chip circuit which is small enough to place in human carotid artery.

  17. 182Hf-182W age dating of a 26Al-poor inclusion and implications for the origin of short-lived radioisotopes in the early Solar System.

    Science.gov (United States)

    Holst, Jesper C; Olsen, Mia B; Paton, Chad; Nagashima, Kazuhide; Schiller, Martin; Wielandt, Daniel; Larsen, Kirsten K; Connelly, James N; Jørgensen, Jes K; Krot, Alexander N; Nordlund, Ake; Bizzarro, Martin

    2013-05-28

    Refractory inclusions [calcium-aluminum-rich inclusions, (CAIs)] represent the oldest Solar System solids and provide information regarding the formation of the Sun and its protoplanetary disk. CAIs contain evidence of now extinct short-lived radioisotopes (e.g., (26)Al, (41)Ca, and (182)Hf) synthesized in one or multiple stars and added to the protosolar molecular cloud before or during its collapse. Understanding how and when short-lived radioisotopes were added to the Solar System is necessary to assess their validity as chronometers and constrain the birthplace of the Sun. Whereas most CAIs formed with the canonical abundance of (26)Al corresponding to (26)Al/(27)Al of ∼5 × 10(-5), rare CAIs with fractionation and unidentified nuclear isotope effects (FUN CAIs) record nucleosynthetic isotopic heterogeneity and (26)Al/(27)Al of Solar System, including the origin of short-lived radioisotopes. However, their chronology is unknown. Using the (182)Hf-(182)W chronometer, we show that a FUN CAI recording a condensation origin from a solar gas formed coevally with canonical CAIs, but with (26)Al/(27)Al of ∼3 × 10(-6). The decoupling between (182)Hf and (26)Al requires distinct stellar origins: steady-state galactic stellar nucleosynthesis for (182)Hf and late-stage contamination of the protosolar molecular cloud by a massive star(s) for (26)Al. Admixing of stellar-derived (26)Al to the protoplanetary disk occurred during the epoch of CAI formation and, therefore, the (26)Al-(26)Mg systematics of CAIs cannot be used to define their formation interval. In contrast, our results support (182)Hf homogeneity and chronological significance of the (182)Hf-(182)W clock.

  18. Influence of implant properties and local delivery systems on the outcome in operative fracture care.

    Science.gov (United States)

    Metsemakers, W-J; Moriarty, T F; Nijs, S; Pape, H C; Richards, R G

    2016-03-01

    Fracture fixation devices are implanted into a growing number of patients each year. This may be attributed to an increase in the popularity of operative fracture care and the development of ever more sophisticated implants, which may be used in even the most difficult clinical cases. Furthermore, as the general population ages, fragility fractures become more frequent. With the increase in number of surgical interventions, the absolute number of complications of these surgical treatments will inevitably rise. Implant-related infection and compromised fracture healing remain the most challenging and prevalent complications in operative fracture care. Any strategy that can help to reduce these complications will not only lead to a faster and more complete resumption of activities, but will also help to reduce the socio-economic impact. In this review we describe the influence of implant design and material choice on complication rates in trauma patients. Furthermore, we discuss the importance of local delivery systems, such as implant coatings and bone cement, and how these systems may have an impact on the prevalence, prevention and treatment outcome of these complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Three-dimensional accuracy of a digitally coded healing abutment implant impression system.

    Science.gov (United States)

    Ng, Simon D; Tan, Keson B; Teoh, K H; Cheng, Ansgar C; Nicholls, Jack I

    2014-01-01

    This study examined the three-dimensional (3D) accuracy of the Encode Impression System (EN) in transferring the locations of two implants from master models to test models and compared this to the direct impression (DI) technique. The effect of interimplant angulation on the 3D accuracy of both impression techniques was also evaluated. Seven sectional polymethyl methacrylate mandibular arch master models were fabricated with implants in the first premolar and first molar positions. The implants were placed parallel to each other or angulated mesiodistally or buccolingually with total divergent angles of 10, 20, or 30 degrees. Each master model was secured onto an aluminum block containing a gauge block, which defined the local coordinate references. Encode healing abutments were attached to the implants before impressions were made for the EN test models; pickup impression copings were attached for the DI test models. For the seven test groups of each impression technique, a total of 70 test models were fabricated (n = 5). The EN test models were sent to Biomet 3i for implant analog placement. The centroid of each implant or implant analog and the angular orientation of the long axis relative to the x- and y-axes were measured with a coordinate measuring machine. Statistical analyses were performed. Impression technique had a significant effect on y distortion, global linear distortion, and absolute xz and yz angular distortions. Interimplant angulation had significant effects on x and y distortions. However, neither impression technique nor interimplant angulation had a significant effect on z distortion. Distortions were observed with both impression techniques. However, the results suggest that EN was less accurate than DI.

  20. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    These days, dental implants are becoming routinely used as a treatment option for rehabilitation of lost teeth. Conventionally, it is only after the completion of bone healing that the dental implants are loaded into the bone. Bone healing time is approximately 3 months and. 6 months for the mandible and maxilla, respectively.

  1. Influence of implant abutment material on the color of different ceramic crown systems.

    Science.gov (United States)

    Dede, Doğu Ömür; Armağanci, Arzu; Ceylan, Gözlem; Celik, Ersan; Cankaya, Soner; Yilmaz, Burak

    2016-11-01

    Ceramics are widely used for anterior restorations; however, clinical color reproduction still constitutes a challenge particularly when the ceramic crowns are used on titanium implant abutments. The purpose of this in vitro study was to investigate the effect of implant abutment material on the color of different ceramic material systems. Forty disks (11×1.5 mm, shade A2) were fabricated from medium-opacity (mo) and high-translucency (ht) lithium disilicate (IPS e.max) blocks, an aluminous ceramic (VITA In-Ceram Alumina), and a zirconia (Zirkonzahn) ceramic system. Disks were fabricated to represent 3 different implant abutments (zirconia, gold-palladium, and titanium) and dentin (composite resin, A2 shade) as background (11×2 mm). Disk-shaped composite resin specimens in A2 shade were fabricated to represent the cement layer. The color measurements of ceramic specimens were made on composite resin abutment materials using a spectrophotometer. CIELab color coordinates were recorded, and the color coordinates measured on composite resin background served as the control group. Color differences (ΔE 00 ) between the control and test groups were calculated. The data were analyzed with 2-way analysis of variance (ANOVA) and compared with the Tukey HSD test (α=.05). The ceramics system, abutment material, and their interaction were significant for ΔE 00 values (P2.25) were observed for lithium disilicate ceramics on titanium abutments (2.46-2.50). The ΔE 00 values of lithium disilicate ceramics for gold-palladium and titanium abutments were significantly higher than for other groups (P2.25) of an implant-supported lithium disilicate ceramic restoration may be clinically unacceptable if it is fabricated over a titanium abutment. Zirconia may be a more suitable abutment material for implant-supported ceramic restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Mechanical fatigue resistance of an implantable branched lead system for a distributed set of longitudinal intrafascicular electrodes

    Science.gov (United States)

    Pena, A. E.; Kuntaegowdanahalli, S. S.; Abbas, J. J.; Patrick, J.; Horch, K. W.; Jung, R.

    2017-12-01

    Objective. A neural interface system has been developed that consists of an implantable stimulator/recorder can with a 15-electrode lead that trifurcates into three bundles of five individual wire longitudinal intrafascicular electrodes. This work evaluated the mechanical fatigue resistance of the branched lead and distributed electrode system under conditions designed to mimic anticipated strain profiles that would be observed after implantation in the human upper arm. Approach. Custom test setups and procedures were developed to apply linear or angular strain at four critical stress riser points on the lead and electrode system. Each test was performed to evaluate fatigue under a high repetition/low amplitude paradigm designed to test the effects of arm movement on the leads during activities such as walking, or under a low repetition/high amplitude paradigm designed to test the effects of more strenuous upper arm activities. The tests were performed on representative samples of the implantable lead system for human use. The specimens were fabricated using procedures equivalent to those that will be used during production of human-use implants. Electrical and visual inspections of all test specimens were performed before and after the testing procedures to assess lead integrity. Main results. Measurements obtained before and after applying repetitive strain indicated that all test specimens retained electrical continuity and that electrical impedance remained well below pre-specified thresholds for detection of breakage. Visual inspection under a microscope at 10×  magnification did not reveal any signs of damage to the wires or silicone sheathing at the stress riser points. Significance. These results demonstrate that the branched lead of this implantable neural interface system has sufficient mechanical fatigue resistance to withstand strain profiles anticipated when the system is implanted in an arm. The novel test setups and paradigms may be useful in

  3. Mechanical fatigue resistance of an implantable branched lead system for a distributed set of longitudinal intrafascicular electrodes.

    Science.gov (United States)

    Pena, A E; Kuntaegowdanahalli, S S; Abbas, J J; Patrick, J; Horch, K W; Jung, R

    2017-12-01

    A neural interface system has been developed that consists of an implantable stimulator/recorder can with a 15-electrode lead that trifurcates into three bundles of five individual wire longitudinal intrafascicular electrodes. This work evaluated the mechanical fatigue resistance of the branched lead and distributed electrode system under conditions designed to mimic anticipated strain profiles that would be observed after implantation in the human upper arm. Custom test setups and procedures were developed to apply linear or angular strain at four critical stress riser points on the lead and electrode system. Each test was performed to evaluate fatigue under a high repetition/low amplitude paradigm designed to test the effects of arm movement on the leads during activities such as walking, or under a low repetition/high amplitude paradigm designed to test the effects of more strenuous upper arm activities. The tests were performed on representative samples of the implantable lead system for human use. The specimens were fabricated using procedures equivalent to those that will be used during production of human-use implants. Electrical and visual inspections of all test specimens were performed before and after the testing procedures to assess lead integrity. Measurements obtained before and after applying repetitive strain indicated that all test specimens retained electrical continuity and that electrical impedance remained well below pre-specified thresholds for detection of breakage. Visual inspection under a microscope at 10×  magnification did not reveal any signs of damage to the wires or silicone sheathing at the stress riser points. These results demonstrate that the branched lead of this implantable neural interface system has sufficient mechanical fatigue resistance to withstand strain profiles anticipated when the system is implanted in an arm. The novel test setups and paradigms may be useful in testing other lead systems.

  4. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  5. Clinical and radiological results of patients treated with three treatment modalities for overdentures on implants of the ITI (R) Dental Implant System - A randomized controlled clinical trial

    NARCIS (Netherlands)

    Wismeijer, D; van Waas, MAJ; Mulder, J; Vermeeren, JIJF; Kalk, W

    In a randomized controlled clinical trial carried out at the Ignatius teaching hospital in Breda, The Netherlands, 110 edentulous patients with severe mandibular bone loss were treated with implants of the ITI(R) Dental Implant System using 3 different treatment strategies: a mandibular overdenture

  6. Cutaneous and systemic hypersensitivity reactions to metallic implants

    DEFF Research Database (Denmark)

    Basko-Plluska, Juliana L; Thyssen, Jacob P; Schalock, Peter C

    2011-01-01

    ) following the insertion of intravascular stents, dental implants, cardiac pacemakers, or implanted gynecologic devices. Despite repeated attempts by researchers and clinicians to further understand this difficult area of medicine, the association between metal sensitivity and cutaneous allergic reactions......Cutaneous reactions to metal implants, orthopedic or otherwise, are well documented in the literature. The first case of a dermatitis reaction over a stainless steel fracture plate was described in 1966. Most skin reactions are eczematous and allergic in nature, although urticarial, bullous......, and vasculitic eruptions may occur. Also, more complex immune reactions may develop around the implants, resulting in pain, inflammation, and loosening. Nickel, cobalt, and chromium are the three most common metals that elicit both cutaneous and extracutaneous allergic reactions from chronic internal exposure...

  7. Primary prevention of peri-implantitis: managing peri-implant mucositis.

    Science.gov (United States)

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; Lambert, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni E; Schwarz, Frank; Serino, Giovanni; Tomasi, Cristiano; Zitzmann, Nicola U

    2015-04-01

    comprising oral hygiene instructions and mechanical debridement revealed a reduction in clinical signs of inflammation; (vii) adjunctive measures (antiseptics, local and systemic antibiotics, air-abrasive devices) were not found to improve the efficacy of professionally administered plaque removal in reducing clinical signs of inflammation. Consensus was reached on recommendations for patients with dental implants and oral health care professionals with regard to the efficacy of measures to manage peri-implant mucositis. It was particularly emphasized that implant placement and prosthetic reconstructions need to allow proper personal cleaning, diagnosis by probing and professional plaque removal. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Impact of implant design on primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  9. Precipitation processes in implanted materials

    International Nuclear Information System (INIS)

    Borders, J.A.

    1978-01-01

    Ion implantation is a nonequilibrium process. It is possible to implant materials with impurities to concentration levels which exceed the solid solubilities. The return of the system to thermodynamic equilibrium is often accomplished by precipitation of the implanted species or a compound involving atoms of both the host and the implanted species. This may involve long time scales when taking place at room temperature or it may take place during the implantation

  10. Zero-fluoroscopy permanent pacemaker implantation using Ensite NavX system: Clinical viability or fanciful technique?

    Science.gov (United States)

    Guo, Ping; Qiu, Jie; Wang, Yan; Chen, Guangzhi; Proietti, Riccardo; Fadhle, Al-Selmi; Zhao, Chunxia; Wen Wang, Dao

    2018-02-01

    Fluoroscopy is the imaging modality routinely used for cardiac device implantation and electrophysiological procedures. Due to the rising concern regarding the harmful effects of radiation exposure to both the patients and operation staffs, novel 3D mapping systems have been developed and implemented in electrophysiological procedure for the navigation of catheters inside the heart chambers. Their applicability in cardiac device implantation has been rarely reported. Our aim is to evaluate the feasibility and safety of permanent pacemaker implantation without fluoroscopy. From January 2012 to June 2016, six patients (50 ± 15 years, four of six were female, one of who was at the 25th week of gestation) who underwent permanent pacemaker implantation were included (zero-fluoroscopy group). Data from 20 consecutive cases of implantation performed under fluoroscopy guidance were chosen as a control group (fluoroscopy group). Total implantation procedure time for single-chamber pacemaker was 51.3 ± 13.1 minutes in the zero-fluoroscopy group and 42.6 ± 7.4 minutes in the fluoroscopy group (P  =  0.155). The implantation procedural time for a dual-chamber pacemaker was 88.3 ± 19.6 minutes and 67.3 ± 7.6 minutes in the zero-fluoroscopy and fluoroscopy groups (P  =  0.013), respectively. No complications were observed during the procedure and the follow-up in the two groups, and all pacemakers worked with satisfactory parameters. Ensite NavX system can be used as a reliable and safe zero-fluoroscopy approach for the implantation of single- or dual-chamber permanent pacemakers in specific patients, such as pregnant women or in extreme situations when the x-ray machine is not available. © 2017 The Authors. Pacing and Clinical Electrophysiology published by Wiley Periodicals, Inc.

  11. Long-term amnioinfusion through a subcutaneously implanted amniotic fluid replacement port system for treatment of PPROM in humans.

    Science.gov (United States)

    Tchirikov, Michael; Steetskamp, Joscha; Hohmann, Manfred; Koelbl, Heinz

    2010-09-01

    To introduce a novel method for the treatment of PPROM (preterm premature rupture of membranes) using continuous amnioinfusion via a subcutaneously implanted port system. After development and testing since 2001 in a fetal sheep model, the port system has been successfully implanted in two humans with PPROM. In the first case, the subcutaneous port system was implanted during the 23rd week of gestation in a 39-year-old 5th-gravida with PPROM since the 18th week of gestation; in the second case, the port system was implanted during the 24th week of gestation in a 27-year-old 3rd gravida with PPROM since the 21st week of gestation. After port implantation, 100ml/h saline solution was infused intermittently into the amniotic cavity. The whole course of treatment was supported by tocolysis. In the cases presented, gestation was terminated by cesarean section, in one case in the 29th week of gestation, and in the other case in the 30th week. The newborns showed no signs of lung hypoplasia and were successfully extubated on the 1st or 2nd day after delivery. Six months later the children did not exhibit any deviation from the normal development. Long-term amnioinfusion via a subcutaneously implanted port system could be used in humans with PPROM for prolongation of pregnancy and to avoid lung hypoplasia. Prospective randomized studies are ongoing. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  12. Finite Element Analysis of Stress Distribution in Three Commonly Used Implant Systems in D2 and D4 Bone Densities

    Directory of Open Access Journals (Sweden)

    C Radha

    2016-01-01

    Materials and Methods : Pro-engineer 3-0 software was used to create the geometric models of the three implant systems (Nobel biocare, Biohorizon, Adin and two bone densities D2 and D4. Six 3D models were created to simulate each one of the three implant systems supporting a metal ceramic crown placed in two different densities of bone D2 and D4. The Poisson′s ratio(΅ and Youngs modulus(E of elasticity were assigned to different materials used for the models. Vertical and oblique loads of 450N each were applied on all six models. Von Mises stress analysis was done with ANSYS software. Results : Von Mises stresses were more within D4 type bone than D2 type, for all the three systems of implants and less stresses were seen in Biohorizon implant followed by Nobel Biocare and Adin implant particularly in D4 bone. Conclusion: The study concluded that the selection of a particular implant system should be based on the scientific research rather than on popularity.

  13. Load-Bearing Capacity and Retention of Newly Developed Micro-Locking Implant Prosthetic System: An In Vitro Pilot Study

    Directory of Open Access Journals (Sweden)

    Jae-Won Choi

    2018-04-01

    Full Text Available The aim of this study was to introduce the newly developed micro-locking implant prosthetic system and to evaluate the resulting its characteristics. To evaluate load-bearing capacity, 25 implants were divided into five groups: external-hexagon connection (EH, internal-octagon connection (IO, internal-hexagon connection (IH, one-body implant (OB, micro-locking implant system (ML. The maximum compressive load was measured using a universal testing machine (UTM according to the ISO 14801. Retention was evaluated in two experiments: (1 a tensile test of the structure modifications of the components (attachment and implant and (2 a tensile test after cyclic loading (total 5,000,000 cycles, 100 N, 2 Hz. The load-bearing capacity of the ML group was not significantly different from the other groups (p > 0.05. The number of balls in the attachment and the presence of a hexagonal receptacle did not show a significant correlation with retention (p > 0.05, but the shape of the retentive groove in the implant post had a statistically significant effect on retention (p < 0.05. On the other hand, the retention loss was observed during the initial 1,000,000 cycles, but an overall constant retention was maintained afterward. Various preclinical studies on this novel micro-locking implant prosthetic system should continue so that it can be applied in clinical practice.

  14. The implantation of a grid-connected PV system at CEPEL

    Energy Technology Data Exchange (ETDEWEB)

    Galdino, Marco Antonio, E-mail: marcoag@cepel.br

    2003-07-01

    This technical report presents the experience undertaken by CEPEL for implantation of a grid connected PV system at its headquarters, located in Rio de Janeiro, RJ, Brazil. This technology, although considered far from Brazilian reach, is expected to grow significantly in the near future. The paper describes briefly several aspects concerning the PV system and the DAS (data acquisition system) implemented in order to allow the continuous evaluation of its performance and operational conditions. The system was installed in December, 2002, and the data are still preliminary. (author)

  15. Accounting Information Systems in Healthcare: A Review of the Literature.

    Science.gov (United States)

    Hammour, Hadal; Househ, Mowafa; Razzak, Hira Abdul

    2017-01-01

    As information technology progresses in Saudi Arabia, the manual accounting systems have become graduallyinadequate for decision needs. Subsequently, private and public healthcare divisions in Saudi Arabia perceive Computerized accounting information system (CAIS) as a vehicle to safeguard efficient and effective flow of information during the analysis, processes, and recording of financial data. Efficient and effective flow of information improvesthe decision making of staff, thereby improving the capability of health care sectors to reduce cost of the medical services.In this paper, we define computerized accounting systems from the point of view of health informatics. Also, the challenges and benefits of supporting CAIS applications in hospitals of Saudi Arabia. With these elements, we conclude that CAIS in Saudi Arabia can serve as a valuable tool for evaluating and controlling the cost of medical services in healthcare sectors. Supplementary education on the significance of having systems of computerized accounting within hospitals for nurses, doctors, and accountants with other health care staff is warranted in future.

  16. Hypertext and three-dimensional computer graphics in an all digital PC-based CAI workstation.

    Science.gov (United States)

    Schwarz, D. L.; Wind, G. G.

    1991-01-01

    In the past several years there has been an enormous increase in the number of computer-assisted instructional (CAI) applications. Many medical educators and physicians have recognized the power and utility of hypertext. Some developers have incorporated simple diagrams, scanned monochrome graphics or still frame photographs from a laser disc or CD-ROM into their hypertext applications. These technologies have greatly increased the role of the microcomputer in education and training. There still remain numerous applications for these tools which are yet to be explored. One of these exciting areas involves the use of three-dimensional computer graphics. An all digital platform increases application portability. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:1807767

  17. From Fertilisation to Implantation in Mammalian Pregnancy—Modulation of Early Human Reproduction by the Endocannabinoid System

    Directory of Open Access Journals (Sweden)

    Justin C. Konje

    2010-09-01

    Full Text Available There is an increasing recognition that the endocannabinoid system is the crucial cytokine-hormone system regulating early human pregnancy. The synchronous development of the fertilized embryo and the endometrium to ensure timely implantation has been shown to be one of the pivotal steps to successful implantation. This development is thought to be regulated by a finely balanced relationship between various components of the endocannabinoid system in the endometrium, the embryo and the Fallopian tube. In addition, this system has also been shown to be involved in the regulation of the development and maturation of the gametes prior to fertilization. In this review, we will examine the evidence from animal and human studies to support the role of the endocannabinoid system in gametogenesis, fertilization, implantation, early pregnancy maintenance, and in immunomodulation of pregnancy. We will discuss the role of the cannabinoid receptors and the enzymes involved in the synthesis and degradation of the key endocannabinoid ligands (e.g., anandamide and 2-arachinoylglycerol in early reproduction.

  18. Intraoperative Cochlear Implant Device Testing Utilizing an Automated Remote System: A Prospective Pilot Study.

    Science.gov (United States)

    Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P

    2018-03-01

    Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote automated system in the apical 10 electrodes (standard 185.4 μV, SD 11.69 vs. CR

  19. Periodontal ligament formation around different types of dental titanium implants. I. The self-tapping screw type implant system

    DEFF Research Database (Denmark)

    Warrer, K; Karring, T; Gotfredsen, K

    1993-01-01

    The aim of this study was to determine if a periodontal ligament can form around self-tapping, screw type titanium dental implants. Implants were inserted in contact with the periodontal ligament of root tips retained in the mandibular jaws of 7 monkeys. In each side of the mandible, 1 premolar......, a periodontal ligament can form on self-tapping, screw type titanium dental implants in areas where a void is present between the surrounding bone and the implant at the time of insertion....... and 2 molars were removed in such a manner that in approximately half the cases, the root tips were retained. Following healing, the experimental areas were examined on radiographs, and sites were selected for the insertion of the implants, so that every second implant would have a close contact...

  20. Dietary Changes over Time in a Caiçara Community from the Brazilian Atlantic Forest

    Directory of Open Access Journals (Sweden)

    Priscila L. MacCord

    2006-12-01

    Full Text Available Because they are occurring at an accelerated pace, changes in the livelihoods of local coastal communities, including nutritional aspects, have been a subject of interest in human ecology. The aim of this study is to explore the dietary changes, particularly in the consumption of animal protein, that have taken place in Puruba Beach, a rural community of caiçaras on the São Paulo Coast, Brazil, over the 10-yr period from 1992-1993 to 2002-2003. Data were collected during six months in 1992-1993 and during the same months in 2002-2003 using the 24-hr recall method. We found an increasing dependence on external products in the most recent period, along with a reduction in fish consumption and in the number of fish species eaten. These changes, possibly associated with other nonmeasured factors such as overfishing and unplanned tourism, may cause food delocalization and a reduction in the use of natural resources. Although the consequences for conservation efforts in the Atlantic Forest and the survival of the caiçaras must still be evaluated, these local inhabitants may be finding a way to reconcile both the old and the new dietary patterns by keeping their houses in the community while looking for sources of income other than natural resources. The prospect shown here may reveal facets that can influence the maintenance of this and other communities undergoing similar processes by, for example, shedding some light on the ecological and economical processes that may occur within their environment and in turn affect the conservation of the resources upon which the local inhabitants depend.

  1. An image-guided planning system for endosseous oral implants.

    Science.gov (United States)

    Verstreken, K; Van Cleynenbreugel, J; Martens, K; Marchal, G; van Steenberghe, D; Suetens, P

    1998-10-01

    A preoperative planning system for oral implant surgery was developed which takes as input computed tomographies (CT's) of the jaws. Two-dimensional (2-D) reslices of these axial CT slices orthogonal to a curve following the jaw arch are computed and shown together with three-dimensional (3-D) surface rendered models of the bone and computer-aided design (CAD)-like implant models. A technique is developed for scanning and visualizing an eventual existing removable prosthesis together with the bone structures. Evaluation of the planning done with the system shows a difference between 2-D and 3-D planning methods. Validation studies measure the benefits of the 3-D approach by comparing plans made in 2-D mode only with those further adjusted using the full 3-D visualization capabilities of the system. The benefits of a 3-D approach are then evident where a prosthesis is involved in the planning. For the majority of the patients, clinically important adjustments and optimizations to the 2-D plans are made once the 3-D visualization is enabled, effectively resulting in a better plan. The alterations are related to bone quality and quantity (p biomechanics (p < 0.005), and esthetics (p < 0.005), and are so obvious that the 3-D plan stands out clearly (p < 0.005). The improvements often avoid complications such as mandibular nerve damage, sinus perforations, fenestrations, or dehiscences.

  2. Implant experience with an implantable hemodynamic monitor for the management of symptomatic heart failure.

    Science.gov (United States)

    Steinhaus, David; Reynolds, Dwight W; Gadler, Fredrik; Kay, G Neal; Hess, Mike F; Bennett, Tom

    2005-08-01

    Management of congestive heart failure is a serious public health problem. The use of implantable hemodynamic monitors (IHMs) may assist in this management by providing continuous ambulatory filling pressure status for optimal volume management. The Chronicle system includes an implanted monitor, a pressure sensor lead with passive fixation, an external pressure reference (EPR), and data retrieval and viewing components. The tip of the lead is placed near the right ventricular outflow tract to minimize risk of sensor tissue encapsulation. Implant technique and lead placement is similar to that of a permanent pacemaker. After the system had been successfully implanted in 148 patients, the type and frequency of implant-related adverse events were similar to a single-chamber pacemaker implant. R-wave amplitude was 15.2 +/- 6.7 mV and the pressure waveform signal was acceptable in all but two patients in whom presence of artifacts required lead repositioning. Implant procedure time was not influenced by experience, remaining constant throughout the study. Based on this evaluation, permanent placement of an IHM in symptomatic heart failure patients is technically feasible. Further investigation is warranted to evaluate the use of the continuous hemodynamic data in management of heart failure patients.

  3. A low power flash-FPGA based brain implant micro-system of PID control.

    Science.gov (United States)

    Lijuan Xia; Fattah, Nabeel; Soltan, Ahmed; Jackson, Andrew; Chester, Graeme; Degenaar, Patrick

    2017-07-01

    In this paper, we demonstrate that a low power flash FPGA based micro-system can provide a low power programmable interface for closed-loop brain implant inter- faces. The proposed micro-system receives recording local field potential (LFP) signals from an implanted probe, performs closed-loop control using a first order control system, then converts the signal into an optogenetic control stimulus pattern. Stimulus can be implemented through optoelectronic probes. The long term target is for both fundamental neuroscience applications and for clinical use in treating epilepsy. Utilizing our device, closed-loop processing consumes only 14nJ of power per PID cycle compared to 1.52μJ per cycle for a micro-controller implementation. Compared to an application specific digital integrated circuit, flash FPGA's are inherently programmable.

  4. Polymer-based wireless implantable sensor and platform for systems biology study

    Science.gov (United States)

    Xue, Ning

    Wireless implantable MEMS (microelectromechanical systems) devices have been developed over the past decade based on the combination of bio-MEMS and Radio frequency (RF) MEMS technology. These devices require the components of wireless telemetric antenna and the corresponding circuit. In the meanwhile, biocompatible material needs to be involved in the devices design. To supply maximum power upon the implantable device at given power supply from the external coil circuit, this dissertation theoretically analyzed the mutual inductance under the positions of variety of vertical distances, lateral displacements and angular misalignments between two coils in certain surgical coils misalignment situations. A planar spiral coil has been developed as the receiver coil of the coupling system. To get maximum induced voltage over the receiver circuit, different geometries of the power coil, system operation frequencies were investigated. An intraocular pressure (IOP) sensor has been developed consisting of only biocompatible matierials-SU-8 and gold. Its size is sufficiently small to be implanted in the eye. The measurement results showed that it has relatively linear pressure response, high resolution and relatively long working stability in saline environment. Finally, a simple and low cost micro-wells bio-chip has been developed with sole polydimethylsiloxane (PDMS) to be used for single cell or small group cells isolation. By performing atomic force microscopy (AFM), contact angle and x-ray photoelectron spectroscopy (XPS) measurements on the PDMS surfaces under various surface treatment conditions, the physical and chemical surface natures were thoroughly analyzed as the basis of study of cells attachment and isolation to the surfaces.

  5. Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.

    Science.gov (United States)

    Depprich, Rita; Zipprich, Holger; Ommerborn, Michelle; Mahn, Eduardo; Lammers, Lydia; Handschel, Jörg; Naujoks, Christian; Wiesmann, Hans-Peter; Kübler, Norbert R; Meyer, Ulrich

    2008-11-06

    The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.

  6. Spiral-Shaped Piezoelectric MEMS Cantilever Array for Fully Implantable Hearing Systems

    Directory of Open Access Journals (Sweden)

    Péter Udvardi

    2017-10-01

    Full Text Available Fully implantable, self-powered hearing aids with no external unit could significantly increase the life quality of patients suffering severe hearing loss. This highly demanding concept, however, requires a strongly miniaturized device which is fully implantable in the middle/inner ear and includes the following components: frequency selective microphone or accelerometer, energy harvesting device, speech processor, and cochlear multielectrode. Here we demonstrate a low volume, piezoelectric micro-electromechanical system (MEMS cantilever array which is sensitive, even in the lower part of the voice frequency range (300–700 Hz. The test array consisting of 16 cantilevers has been fabricated by standard bulk micromachining using a Si-on-Insulator (SOI wafer and aluminum nitride (AlN as a complementary metal-oxide-semiconductor (CMOS and biocompatible piezoelectric material. The low frequency and low device footprint are ensured by Archimedean spiral geometry and Si seismic mass. Experimentally detected resonance frequencies were validated by an analytical model. The generated open circuit voltage (3–10 mV is sufficient for the direct analog conversion of the signals for cochlear multielectrode implants.

  7. An Unusual Bone Loss Around Implants

    Directory of Open Access Journals (Sweden)

    Amirreza Rokn

    2013-01-01

    Full Text Available AbstractPre-implant disease is an inflammatory process, which can affect the surrounding tissues of a functional Osseointegrated implant that is usually as a result of a disequilibrium between the micro-flora and the body defense system.This case reports a 57 years old male with unusual bone loss around dental implants.This was an unusual case of peri-implantitis which occurred only in the implants on one side of the mouth although they all were unloaded implants.

  8. DRUGAS: implantable telemetric system for measuring the portal venous pressure: assembly aspects

    Directory of Open Access Journals (Sweden)

    Fischer Roland

    2017-09-01

    Full Text Available Developing an implantable, telemetric pressure measuring system for venous applications makes a high degree of miniaturization necessary. Thus the influence on the measurement environment is minimized and the risk of thrombosis at small flow blood velocities is decreased. But these systems are limited in terms of accuracy and resolution. The asked system requirements could only be reached by optimising the assembly and encapsulation techniques. To achieve the high degree of miniaturization numerical simulations were performed on the shape and size of the implant and led to the development of a specific metal housing consisting of two main components. A small measuring chamber will be placed into the portal vein and is rigidly fixed to a flat circular part that contains the pressure sensor chip and a transponder board and will be located outside on top of the vein. The main focus of the assembly process was based on a stress-free design and mounting of the components.

  9. Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element analysis.

    Science.gov (United States)

    Hong, Hae Ryong; Pae, Ahran; Kim, Yooseok; Paek, Janghyun; Kim, Hyeong-Seob; Kwon, Kung-Rock

    2012-01-01

    The aim of this study was to analyze and compare the level and distribution of peri-implant bone stresses associated with mandibular two-implant overdentures with different implant positions. Mathematical models of mandibles and overdentures were designed using finite element analysis software. Two intraosseous implants and ball attachment systems were placed in the interforaminal region. The overdenture, which was supported by the two implants, was designed to withstand bilateral and unilateral vertical masticatory loads (total 100 N). In all, eight types of models, which differed according to assigned implant positions, height of attachments, and angulation, were tested: MI (model with implants positioned in the lateral incisor sites), MC (implants in canine sites), MP (implants in premolar sites), MI-Hi (greater height of attachments), MC-M (canine implants placed with mesial inclination), MC-D (canine implants placed with distal inclination), MC-B (canine implants placed with buccal inclination), and MC-L (canine implants placed with lingual inclination). Peri-implant bone stress levels associated with overdentures retained by lateral incisor implants resulted in the lowest stress levels and the highest efficiency in distributing peri-implant stress. MI-Hi showed increased stress levels and decreased efficiency in stress distribution. As the implants were inclined, stress levels increased and the efficiency of stress distribution decreased. Among the inclined models, MC-B showed the lowest stress level and best efficiency in stress distribution. The lowest stress and the best stability of implants in mandibular two-implant overdentures were obtained when implants were inserted in lateral incisor areas with shorter attachments and were placed parallel to the long axes of the teeth.

  10. Embedded System for Prosthetic Control Using Implanted Neuromuscular Interfaces Accessed Via an Osseointegrated Implant.

    Science.gov (United States)

    Mastinu, Enzo; Doguet, Pascal; Botquin, Yohan; Hakansson, Bo; Ortiz-Catalan, Max

    2017-08-01

    Despite the technological progress in robotics achieved in the last decades, prosthetic limbs still lack functionality, reliability, and comfort. Recently, an implanted neuromusculoskeletal interface built upon osseointegration was developed and tested in humans, namely the Osseointegrated Human-Machine Gateway. Here, we present an embedded system to exploit the advantages of this technology. Our artificial limb controller allows for bioelectric signals acquisition, processing, decoding of motor intent, prosthetic control, and sensory feedback. It includes a neurostimulator to provide direct neural feedback based on sensory information. The system was validated using real-time tasks characterization, power consumption evaluation, and myoelectric pattern recognition performance. Functionality was proven in a first pilot patient from whom results of daily usage were obtained. The system was designed to be reliably used in activities of daily living, as well as a research platform to monitor prosthesis usage and training, machine-learning-based control algorithms, and neural stimulation paradigms.

  11. A New Type of Foreign Clast in A Polymict Ureilite: A CAI or AL-Rich Chondrule

    Science.gov (United States)

    Goodrich, C. A.; Ross, D. K.; Treiman, A. H.

    2017-01-01

    Introduction: Polymict ureilites are breccias interpreted to represent regolith formed on a ureilitic asteroid [1-3]. They consist of approximately 90-95% clasts of various ureilite types (olivine-pyroxene rocks with Fo 75-95), a few % indigenous feldspathic clasts, and a few % foreign clasts [4-20]. The foreign clasts are diverse, including fragments of H, L, LL and R chondrites, angrites, other achondrites, and dark clasts similar to CC [6,7,9-19]. We report a new type of foreign clast in polymict ureilite DaG 999. Methods: Clast 8 in Dar al Gani (DaG) 999/1 (Museum fur Naturkunde) was discovered during a survey of feldspathic clasts in polymict ureilites [19,20]. It was studied by BEI, EMPA, and X-ray mapping on the JEOL 8530F electron microprobe at ARES, JSC. Petrography and Mineral Compositions: Clast 8 is sub-rounded to irregular in shape, approximately 85 micrometers in diameter, and consists of approximately 68% pyroxene and 32% mesostasis (by area). Part of the pyroxene (top half of clast in Fig. 1a and 2) shows a coarse dendritic morphology; the rest appears massive. Mesostasis may be glassy and contains fine needles/grains of pyroxene. The pyroxene has very high CaO (23.5 wt.%) and Al2O3 (19.7 wt.%), with the formula: (Ca(0.91)Mg(0.63)Fe(0.01)Al(sup VI) (0.38)Cr(0.01)Ti(0.05)1.99 Si2O6. The bulk mesostasis also has very high Al2O3 (approximately 26 wt.%). A bulk composition for the clast was obtained by combining modal abundances with phase compositions (Table 1, Fig. 3). Discussion: The pyroxene in clast 8 has a Ca-Al-(Ti)- rich (fassaitic) composition that is clearly distinct from compositions of pyroxenes in main group ureilites [22] or indigenous feldspathic clasts in polymict ureilites [4-8]. It also has significantly higher Al than fassaite in angrites (up to approximately 12 wt.% [23]), which occur as xenoliths in polymict ureilites. Ca-Al-Ti rich pyroxenes are most commonly found in CAIs, Al-rich chondrules and other types of refractory

  12. [Fusion implants of carbon fiber reinforced plastic].

    Science.gov (United States)

    Früh, H J; Liebetrau, A; Bertagnoli, R

    2002-05-01

    Carbon fiber reinforced plastics (CFRP) are used in the medical field when high mechanical strength, innovative design, and radiolucency (see spinal fusion implants) are needed. During the manufacturing process of the material CFRP carbon fibers are embedded into a resin matrix. This resin material could be thermoset (e.g., epoxy resin EPN/DDS) or thermoplastic (e.g., PEAK). CFRP is biocompatible, radiolucent, and has higher mechanical capabilities compared to other implant materials. This publication demonstrates the manufacturing process of fusion implants made of a thermoset matrix system using a fiber winding process. The material has been used clinically since 1994 for fusion implants of the cervical and lumbar spine. The results of the fusion systems CORNERSTONE-SR C (cervical) and UNION (lumbar) showed no implant-related complications. New implant systems made of this CFRP material are under investigation and are presented.

  13. The influence of direct laser metal sintering implants on the early stages of osseointegration in diabetic mini-pigs

    Directory of Open Access Journals (Sweden)

    Tan NW

    2017-07-01

    Full Text Available Naiwen Tan,1–3,* Xiangwei Liu,1,2,* Yanhui Cai,4 Sijia Zhang,1,2 Bo Jian,1,2 Yuchao Zhou,1,2 Xiaoru Xu,1,2 Shuai Ren,1,2 Hongbo Wei,1,2 Yingliang Song1,2 1State Key Laboratory of Military Stomatology, National Clinical Research Center for Oral Diseases, Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Xi’an, Shaanxi, China; 2Department of Implant Dentistry, School of Stomatology, The Fourth Military Medical University, Xi’an, Shaanxi, China; 3Department of Stomatology, Hospital 463 of PLA, Xi’an, Shaanxi, China; 4Department of Anesthesiology, Xijing Hospital, The Fourth Military Medical University, Xi’an, Shaanxi, China *These authors contributed equally to this work Background: High failure rates of oral implants have been reported in diabetic patients due to the disruption of osseointegration. The aim of this study was to investigate whether direct laser metal sintering (DLMS could improve osseointegration in diabetic animal models. Methods: Surface characterizations were carried out on two types of implants. Cell morphology and the osteogenic-related gene expression of MG63 cells were observed under conditions of DLMS and microarc oxidation (MAO. A diabetes model in mini-pigs was established by intravenous injection of streptozotocin (150 mg/kg, and a total of 36 implants were inserted into the mandibular region. Micro-computed tomography (micro-CT and histologic evaluations were performed 3 and 6 months after implantation. Results: The Ra (the average of the absolute height of all points of MAO surface was 2.3±0.3 µm while the DLMS surface showed the Ra of 27.4±1.1 µm. The cells on DLMS implants spread out more podia than those on MAO implants through cell morphology analysis. Osteogenic-related gene expression was also dramatically increased in the DLMS group. Obvious improvement was observed in the micro-CT and Van Gieson staining analyses of DLMS implants compared with MAO at 3 months

  14. Implanting inequality: empirical evidence of social and ethical risks of implantable radio-frequency identification (RFID) devices.

    Science.gov (United States)

    Monahan, Torin; Fisher, Jill A

    2010-10-01

    The aim of this study was to assess empirically the social and ethical risks associated with implantable radio-frequency identification (RFID) devices. Qualitative research included observational studies in twenty-three U.S. hospitals that have implemented new patient identification systems and eighty semi-structured interviews about the social and ethical implications of new patient identification systems, including RFID implants. The study identified three primary social and ethical risks associated with RFID implants: (i) unfair prioritization of patients based on their participation in the system, (ii) diminished trust of patients by care providers, and (iii) endangerment of patients who misunderstand the capabilities of the systems. RFID implants may aggravate inequalities in access to care without any clear health benefits. This research underscores the importance of critically evaluating new healthcare technologies from the perspective of both normative ethics and empirical ethics.

  15. Complication incidence of two implant systems up to six years: a comparison between internal and external connection implants.

    Science.gov (United States)

    Chae, Sung-Wook; Kim, Young-Sung; Lee, Yong-Moo; Kim, Won-Kyung; Lee, Young-Kyoo; Kim, Su-Hwan

    2015-02-01

    This study was conducted to compare the cumulative survival rates (CSRs) and the incidence of postloading complications (PLCs) between a bone-level internal connection system (ICS-BL) and an external connection system (ECS). The medical records of patients treated with either a ICS-BL or ECS between 2007 and 2010 at Asan Medical Center were reviewed. PLCs were divided into two categories: biological and technical. Biological complications included >4 mm of probing pocket depth, thread exposure in radiographs, and soft tissue complications, whereas technical complications included chipping of the veneering material, fracture of the implant, fracture of the crown, loosening or fracture of the abutment or screw, loss of retention, and loss of access hole filling material. CSRs were determined by a life-table analysis and compared using the log-rank chi-square test. The incidence of PLC was compared with the Pearson chi-squared test. A total of 2,651 implants in 1,074 patients (1,167 ICS-BLs in 551 patients and 1,484 ECSs in 523 patients) were analyzed. The average observation periods were 3.4 years for the ICS-BLs and 3.1 years for the ECSs. The six-year CSR of all implants was 96.1% (94.9% for the ICS-BLs and 97.1% for the ECSs, P=0.619). Soft tissue complications were more frequent with the ECSs (P=0.005) and loosening or fracture of the abutment or screw occurred more frequently with the ICS-BLs (Plimitations of this study, the ICS-BL was more prone to technical complications while the ECS was more vulnerable to biological complications.

  16. A biomechanical testing system to determine micromotion between hip implant and femur accounting for deformation of the hip implant: Assessment of the influence of rigid body assumptions on micromotions measurements.

    Science.gov (United States)

    Leuridan, Steven; Goossens, Quentin; Roosen, Jorg; Pastrav, Leonard; Denis, Kathleen; Mulier, Michiel; Desmet, Wim; Vander Sloten, Jos

    2017-02-01

    Accurate pre-clinical evaluation of the initial stability of new cementless hip stems using in vitro micromotion measurements is an important step in the design process to assess the new stem's potential. Several measuring systems, linear variable displacement transducer-based and other, require assuming bone or implant to be rigid to obtain micromotion values or to calculate derived quantities such as relative implant tilting. An alternative linear variable displacement transducer-based measuring system not requiring a rigid body assumption was developed in this study. The system combined advantages of local unidirectional and frame-and-bracket micromotion measuring concepts. The influence and possible errors that would be made by adopting a rigid body assumption were quantified. Furthermore, as the system allowed emulating local unidirectional and frame-and-bracket systems, the influence of adopting rigid body assumptions were also analyzed for both concepts. Synthetic and embalmed bone models were tested in combination with primary and revision implants. Single-legged stance phase loading was applied to the implant - bone constructs. Adopting a rigid body assumption resulted in an overestimation of mediolateral micromotion of up to 49.7μm at more distal measuring locations. Maximal average relative rotational motion was overestimated by 0.12° around the anteroposterior axis. Frontal and sagittal tilting calculations based on a unidirectional measuring concept underestimated the true tilting by an order of magnitude. Non-rigid behavior is a factor that should not be dismissed in micromotion stability evaluations of primary and revision femoral implants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Ion beam system for implanting industrial products of various shapes

    International Nuclear Information System (INIS)

    Denholm, A.S.; Wittkower, A.

    1985-01-01

    Implantation of metals and ceramics with ions of nitrogen and other species has improved surface properties such as friction, wear and corrosion in numerous industrial applications. Zymet has built a production machine to take advantage of this process which can implant a 2 x 10 17 ions/cm 2 dose of nitrogen ions into a 20 cm x 20 cm area in about 30 min using a 100 keV beam. Treatment is accomplished by mounting the product on a cooled, tiltable, turntable which rotates continuously, or is indexed in 15 0 steps to expose different surfaces in fixed position. Product cooling is accomplished by using a chilled eutectic metal to mount and grip the variously shaped objects. A high voltage supply capable of 10 mA at 100 kV is used, and the equipment is microcomputer controlled via serial light links. All important machine parameters are presented in sequenced displays on a CRT. Uniformity of treatment and accumulated dose are monitored by a Faraday cup system which provides the microprocessor with data for display of time to completion on the process screen. For routine implants the operator requires only two buttons; one for chamber vacuum control, and the other for process start and stop. (orig.)

  18. Implementation of wireless power transfer and communications for an implantable ocular drug delivery system.

    Science.gov (United States)

    Tang, T B; Smith, S; Flynn, B W; Stevenson, J T M; Gundlach, A M; Reekie, H M; Murray, A F; Renshaw, D; Dhillon, B; Ohtori, A; Inoue, Y; Terry, J G; Walton, A J

    2008-09-01

    A wireless power transfer and communication system based on near-field inductive coupling has been designed and implemented. The feasibility of using such a system to remotely control drug release from an implantable drug delivery system is addressed. The architecture of the wireless system is described and the signal attenuation over distance in both water and phosphate buffered saline is studied. Additionally, the health risk due to exposure to radio frequency (RF) radiation is examined using a biological model. The experimental results demonstrate that the system can trigger the release of drug within 5 s, and that such short exposure to RF radiation does not produce any significant (system could replace a chemical battery in an implantable system, eliminating the risks associated with battery failure and leakage and also allowing more compact designs for applications such as drug delivery.

  19. Location of unaccessible implant surface areas during debridement in simulated peri-implantitis therapy

    OpenAIRE

    Steiger-Ronay, Valerie; Merlini, Andrea; Wiedemeier, Daniel B.; Schmidlin, Patrick R.; Attin, Thomas; Sahrmann, Philipp

    2017-01-01

    Background An in vitro model for peri-implantitis treatment was used to identify areas that are clinically difficult to clean by analyzing the pattern of residual stain after debridement with commonly employed instruments. Methods Original data from two previous publications, which simulated surgical (SA) and non-surgical (NSA) implant debridement on two different implant systems respectively, were reanalyzed regarding the localization pattern of residual stains after instrumentation. Two bli...

  20. Electromagnetic Interference in Patients with Implanted Cardioverter-Defibrillators and Implantable Loop Recorders

    Directory of Open Access Journals (Sweden)

    Marcos de Sousa

    2002-07-01

    Full Text Available Modern life exposes us all to an ever-increasing number of potential sources of electromagnetic interference (EMI and patients with Implantable rhythm devices (IRD like pacemakers, implantable cardioverter defibrillators or implantable loop recorders often ask about the use of microwave ovens, walking through airport metal detectors and the use of cellular phones. Electromagnetic interference occurs when electromagnetic waves emitted by one device impede the normal function of another electronic device. The potential for interaction between implanted pacing systems and cardioverter-defibrillators (electromagnetic interference, EMI has been recognized for years.1,2,3,4. It has been shown that EMI can produce clinically significant effects on patients with implanted pacemakers and ICDs. For these reasons the following text discusses the influence of several EMI generating devices on IRD .

  1. Description of the condition of the implant-prosthesis system: a transverse study

    International Nuclear Information System (INIS)

    Salazar Salgado, Walter

    2008-01-01

    Current condition of the implant-prosthesis system of the patients attended in the Facultad de Odontologia de la Universidad de Costa Rica is described, in the included period from January 2001 to December 2006. Parameters of comparison will be established for future evaluations. An appointment was scheduled with each patient to review. A radiovisiograph was used for digital radiography with parallel technique and radiographic positioners, for anterior and posterior sector. In addition, a questionnaire was applied to all patients. The percentage of survival of the implants placed in the years 2001-2006, is 95.2 % and 92.4 % of the patients are satisfied with the aesthetic aspect of their restoration [es

  2. Accuracy of two digital implant impression systems based on confocal microscopy with variations in customized software and clinical parameters.

    Science.gov (United States)

    Giménez, Beatriz; Pradíes, Guillermo; Martínez-Rus, Francisco; Özcan, Mutlu

    2015-01-01

    To evaluate the accuracy of two digital impression systems based on the same technology but different postprocessing correction modes of customized software, with consideration of several clinical parameters. A maxillary master model with six implants located in the second molar, second premolar, and lateral incisor positions was fitted with six cylindrical scan bodies. Scan bodies were placed at different angulations or depths apical to the gingiva. Two experienced and two inexperienced operators performed scans with either 3D Progress (MHT) or ZFX Intrascan (Zimmer Dental). Five different distances between implants (scan bodies) were measured, yielding five data points per impression and 100 per impression system. Measurements made with a high-accuracy three-dimensional coordinate measuring machine (CMM) of the master model acted as the true values. The values obtained from the digital impressions were subtracted from the CMM values to identify the deviations. The differences between experienced and inexperienced operators and implant angulation and depth were compared statistically. Experience of the operator, implant angulation, and implant depth were not associated with significant differences in deviation from the true values with both 3D Progress and ZFX Intrascan. Accuracy in the first scanned quadrant was significantly better with 3D Progress, but ZFX Intrascan presented better accuracy in the full arch. Neither of the two systems tested would be suitable for digital impression of multiple-implant prostheses. Because of the errors, further development of both systems is required.

  3. Influence of Implant Positions and Occlusal Forces on Peri-Implant Bone Stress in Mandibular Two-Implant Overdentures: A 3-Dimensional Finite Element Analysis.

    Science.gov (United States)

    Alvarez-Arenal, Angel; Gonzalez-Gonzalez, Ignacio; deLlanos-Lanchares, Hector; Brizuela-Velasco, Aritza; Dds, Elena Martin-Fernandez; Ellacuria-Echebarria, Joseba

    2017-12-01

    The aim of this study was to evaluate and compare the bone stress around implants in mandibular 2-implant overdentures depending on the implant location and different loading conditions. Four 3-dimensional finite element models simulating a mandibular 2-implant overdenture and a Locator attachment system were designed. The implants were located at the lateral incisor, canine, second premolar, and crossed-implant levels. A 150 N unilateral and bilateral vertical load of different location was applied, as was 40 N when combined with midline load. Data for von Mises stress were produced numerically, color coded, and compared between the models for peri-implant bone and loading conditions. With unilateral loading, in all 4 models much higher peri-implant bone stress values were recorded on the load side compared with the no-load side, while with bilateral occlusal loading, the stress distribution was similar on both sides. In all models, the posterior unilateral load showed the highest stress, which decreased as the load was applied more mesially. In general, the best biomechanical environment in the peri-implant bone was found in the model with implants at premolar level. In the crossed-implant model, the load side greatly altered the biomechanical environment. Overall, the overdenture with implants at second premolar level should be the chosen design, regardless of where the load is applied. The occlusal loading application site influences the bone stress around the implant. Bilateral occlusal loading distributes the peri-implant bone stress symmetrically, while unilateral loading increases it greatly on the load side, no matter where the implants are located.

  4. A simple ion implantation system for solar cells

    International Nuclear Information System (INIS)

    Kenny, M.J.; Bird, J.R.; Broe, H.G.

    1982-11-01

    A project has been initiated to investigate simple but effective ion implantation and pulsed annealing techniques for the fabrication of high efficiency silicon solar cells. In particular, the method aims to eliminate the mass analyser and associated components from the implanter. A solid feed source is used in a clean ultra high vacuum environment to minimise impurities

  5. Localization and Tracking of Implantable Biomedical Sensors

    Directory of Open Access Journals (Sweden)

    Ilknur Umay

    2017-03-01

    Full Text Available Implantable sensor systems are effective tools for biomedical diagnosis, visualization and treatment of various health conditions, attracting the interest of researchers, as well as healthcare practitioners. These systems efficiently and conveniently provide essential data of the body part being diagnosed, such as gastrointestinal (temperature, pH, pressure parameter values, blood glucose and pressure levels and electrocardiogram data. Such data are first transmitted from the implantable sensor units to an external receiver node or network and then to a central monitoring and control (computer unit for analysis, diagnosis and/or treatment. Implantable sensor units are typically in the form of mobile microrobotic capsules or implanted stationary (body-fixed units. In particular, capsule-based systems have attracted significant research interest recently, with a variety of applications, including endoscopy, microsurgery, drug delivery and biopsy. In such implantable sensor systems, one of the most challenging problems is the accurate localization and tracking of the microrobotic sensor unit (e.g., robotic capsule inside the human body. This article presents a literature review of the existing localization and tracking techniques for robotic implantable sensor systems with their merits and limitations and possible solutions of the proposed localization methods. The article also provides a brief discussion on the connection and cooperation of such techniques with wearable biomedical sensor systems.

  6. A detection system for charged-particle decay studies with a continuous-implantation method

    Energy Technology Data Exchange (ETDEWEB)

    Sun, L.J. [China Institute of Atomic Energy, Beijing 102413 (China); Xu, X.X., E-mail: xuxinxing@ciae.ac.cn [China Institute of Atomic Energy, Beijing 102413 (China); Lin, C.J., E-mail: cjlin@ciae.ac.cn [China Institute of Atomic Energy, Beijing 102413 (China); Wang, J.S. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Fang, D.Q. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Li, Z.H. [School of Physic and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Wang, Y.T. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Li, J. [School of Physic and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Yang, L.; Ma, N.R. [China Institute of Atomic Energy, Beijing 102413 (China); Wang, K. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Zang, H.L. [School of Physic and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Wang, H.W.; Li, C.; Shi, C.Z.; Nie, M.W.; Li, X.F.; Li, H. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Ma, J.B.; Ma, P. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); and others

    2015-12-21

    A new detection system with high detection efficiency and low detection threshold has been developed for charged-particle decay studies, including β-delayed proton, α decay or direct proton emission from proton-rich nuclei. The performance was evaluated by using the β-delayed proton emitter {sup 24}Si produced by projectile fragmentation at the First Radioactive Ion Beam Line in Lanzhou. Under a continuous-beam mode, the isotopes of interest were implanted into two double-sided silicon strip detectors, where the subsequent decays were measured and correlated to the preceding implantations by using position and time information. The system allows us to measure protons with energies down to about 200 keV without obvious β background in the proton spectrum. Further application of the detection system can be extended to the measurements of β-delayed proton decay and the direct proton emission of more exotic proton-rich nuclei.

  7. 21 CFR 880.6300 - Implantable radiofrequency transponder system for patient identification and health information.

    Science.gov (United States)

    2010-04-01

    ... patient identification and health information. 880.6300 Section 880.6300 Food and Drugs FOOD AND DRUG... radiofrequency transponder system for patient identification and health information. (a) Identification. An implantable radiofrequency transponder system for patient identification and health information is a device...

  8. A classification of growth friendly spine implants.

    Science.gov (United States)

    Skaggs, David L; Akbarnia, Behrooz A; Flynn, John M; Myung, Karen S; Sponseller, Paul D; Vitale, Michael G

    2014-01-01

    Various types of spinal implants have been used with the objective of minimizing spinal deformities while maximizing the spine and thoracic growth in a growing child with a spinal deformity. The aim of this study was to describe a classification system of growth friendly spinal implants to allow researchers and clinicians to have a common language and facilitate comparative studies. Growth friendly spinal implant systems fall into 3 categories based upon the forces of correction the implants exert on the spine, which are as follows: Distraction-based systems correct spinal deformities by mechanically applying a distractive force across a deformed segment with anchors at the top and bottom of the implants, which commonly attach to the spine, rib, and/or the pelvis. The present examples of distraction-based implants are spine-based or rib-based growing rods, vertical expandable titanium rib prosthesis, and remotely expandable devices. Compression-based systems correct spinal deformities with a compressive force applied to the convexity of the curve causing convex growth inhibition. This compressive force may be generated both mechanically at the time of implantation, as well as over time resulting from longitudinal growth of vertebral endplates hindered by the spinal implants. Examples of compression-based systems are vertebral staples and tethers. Guided growth systems correct spinal deformity by anchoring multiple vertebrae (usually including the apical vertebrae) to rods with mechanical forces including translation at the time of the initial implant. The majority of the anchors are not rigidly attached to the rods, thus permitting longitudinal growth over time as the anchors slide over the rods. Examples of guided growth systems include the Luque trolley and Shilla. Each system has its benefits and shortcomings. Knowledge of the fundamental principles upon which these systems are based may aid the clinician to choose an appropriate treatment for patients. Having a

  9. Augmentation Mammaplasty Using Implants: A Review

    Directory of Open Access Journals (Sweden)

    Susumu Takayanagi

    2012-09-01

    Full Text Available One of the techniques for augmentation mammaplasty is the procedure using implants. Eventhough this technique has been used for many years, there are still several controversial issuesto be discussed and overcome for patient safety. In this review article, capsular contracture,leak or rupture of the implants, possible systemic disease, relation with breast cancer, andrecent problems with Poly Implant Prothese implants are described and discussed.

  10. Randomized study on the effect of single-implant versus two-implant retained overdentures on implant loss and muscle activity: a 12-month follow-up report.

    Science.gov (United States)

    Alqutaibi, A Y; Kaddah, A F; Farouk, M

    2017-06-01

    The objective was to evaluate and compare single- and two-implant retained overdentures for the rehabilitation of the edentulous mandible. Fifty-six edentulous subjects were eligible for inclusion. Using a random sampling system, a single implant or two implants were placed in the mandible. After 3 months, locator attachments were connected to the implants and the denture delivered with the retentive components incorporated in the denture base. Implant failure and muscle activity were evaluated at the 3-, 6-, and 12-month follow-up examinations. The study sample comprised 56 patients (32 male, 24 female), with a mean age of 58.2 years. A total of 84 implants were placed (28 in the single-implant group and 56 in the two-implant group). All patients completed the 12 months of follow-up. No significant differences were found between subjects in the two groups with respect to implant failure. With regard to improvements in muscle activity, the two-implant group showed statistically significant but perhaps not clinically important differences. Single-implant mandibular overdentures may be suggested as an alternative treatment modality for the rehabilitation of edentulous patients who cannot afford the cost of a two-implant overdenture. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Augmentation Mammaplasty Using Implants: A Review

    Directory of Open Access Journals (Sweden)

    Susumu Takayanagi

    2012-09-01

    Full Text Available One of the techniques for augmentation mammaplasty is the procedure using implants. Even though this technique has been used for many years, there are still several controversial issues to be discussed and overcome for patient safety. In this review article, capsular contracture, leak or rupture of the implants, possible systemic disease, relation with breast cancer, and recent problems with Poly Implant Prothese implants are described and discussed.

  12. Cutaneous and systemic hypersensitivity reactions to metallic implants.

    Science.gov (United States)

    Basko-Plluska, Juliana L; Thyssen, Jacob P; Schalock, Peter C

    2011-01-01

    Cutaneous reactions to metal implants, orthopedic or otherwise, are well documented in the literature. The first case of a dermatitis reaction over a stainless steel fracture plate was described in 1966. Most skin reactions are eczematous and allergic in nature, although urticarial, bullous, and vasculitic eruptions may occur. Also, more complex immune reactions may develop around the implants, resulting in pain, inflammation, and loosening. Nickel, cobalt, and chromium are the three most common metals that elicit both cutaneous and extracutaneous allergic reactions from chronic internal exposure. However, other metal ions as well as bone cement components can cause such hypersensitivity reactions. To complicate things, patients may also develop delayed-type hypersensitivity reactions to metals (ie, in-stent restenosis, prosthesis loosening, inflammation, pain, or allergic contact dermatitis) following the insertion of intravascular stents, dental implants, cardiac pacemakers, or implanted gynecologic devices. Despite repeated attempts by researchers and clinicians to further understand this difficult area of medicine, the association between metal sensitivity and cutaneous allergic reactions remains to be fully understood. This review provides an update of the current knowledge in this field and should be valuable to health care providers who manage patients with conditions related to this field.

  13. Immunological Response to Biodegradable Magnesium Implants

    Science.gov (United States)

    Pichler, Karin; Fischerauer, Stefan; Ferlic, Peter; Martinelli, Elisabeth; Brezinsek, Hans-Peter; Uggowitzer, Peter J.; Löffler, Jörg F.; Weinberg, Annelie-Martina

    2014-04-01

    The use of biodegradable magnesium implants in pediatric trauma surgery would render surgical interventions for implant removal after tissue healing unnecessary, thereby preventing stress to the children and reducing therapy costs. In this study, we report on the immunological response to biodegradable magnesium implants—as an important aspect in evaluating biocompatibility—tested in a growing rat model. The focus of this study was to investigate the response of the innate immune system to either fast or slow degrading magnesium pins, which were implanted into the femoral bones of 5-week-old rats. The main alloying element of the fast-degrading alloy (ZX50) was Zn, while it was Y in the slow-degrading implant (WZ21). Our results demonstrate that degrading magnesium implants beneficially influence the immune system, especially in the first postoperative weeks but also during tissue healing and early bone remodeling. However, rodents with WZ21 pins showed a slightly decreased phagocytic ability during bone remodeling when the degradation rate reached its maximum. This may be due to the high release rate of the rare earth-element yttrium, which is potentially toxic. From our results we conclude that magnesium implants have a beneficial effect on the innate immune system but that there are some concerns regarding the use of yttrium-alloyed magnesium implants, especially in pediatric patients.

  14. A wirelessly controlled implantable LED system for deep brain optogenetic stimulation

    Science.gov (United States)

    Rossi, Mark A.; Go, Vinson; Murphy, Tracy; Fu, Quanhai; Morizio, James; Yin, Henry H.

    2015-01-01

    In recent years optogenetics has rapidly become an essential technique in neuroscience. Its temporal and spatial specificity, combined with efficacy in manipulating neuronal activity, are especially useful in studying the behavior of awake behaving animals. Conventional optogenetics, however, requires the use of lasers and optic fibers, which can place considerable restrictions on behavior. Here we combined a wirelessly controlled interface and small implantable light-emitting diode (LED) that allows flexible and precise placement of light source to illuminate any brain area. We tested this wireless LED system in vivo, in transgenic mice expressing channelrhodopsin-2 in striatonigral neurons expressing D1-like dopamine receptors. In all mice tested, we were able to elicit movements reliably. The frequency of twitches induced by high power stimulation is proportional to the frequency of stimulation. At lower power, contraversive turning was observed. Moreover, the implanted LED remains effective over 50 days after surgery, demonstrating the long-term stability of the light source. Our results show that the wireless LED system can be used to manipulate neural activity chronically in behaving mice without impeding natural movements. PMID:25713516

  15. [A totally implantable venous access device. Implantation in general or local anaesthesia? A retrospective cost analysis].

    Science.gov (United States)

    Schuld, J; Richter, S; Moussavian, M R; Kollmar, O; Schilling, M K

    2009-08-01

    Implantation of venous access port systems can be performed in local or general anesthesia. In spite of the increasing rate of interventionally implanted systems, the surgical cut-down represents a safe alternative. Thus, the question arises whether--in context to the increasing health-economic pressure--open implantation in general anesthesia is still a feasible alternative to implantation in local anesthesia regarding OR efficiency and costs. In a retrospective analysis, 993 patients receiving a totally implantable venous access device between 2001 and 2007 were evaluated regarding OR utilization, turnover times, intraoperative data and costs. Implantations in local (LA) and general anesthesia (GA) were compared. GA was performed in 762 cases (76.6 %), LA was performed in 231 patients (23.3 %). Mean operation time was similar in both groups (LA 47.27 +/- 1.40 min vs. GA 45.41 +/- 0.75 min, p = 0.244). Patients receiving local anesthesia had a significantly shorter stay in the OR unit (LA 95.9 +/- 1.78 min vs. GA 105.92 +/- 0.92 min; p cut (LA 39.57 +/- 0.69 min vs. GA 50.46 +/- 0.52 min; p material costs were significantly lower in the LA group compared with the GA group (LA: 400.72 +/- 8.25 euro vs. GA: 482.86 +/- 6.23 euro; p systems in local anesthesia is superior in comparison to the implantation under general anesthesia regarding procedural times in the OR unit and costs. With the same operation duration, but less personnel and material expenditure, implantation in local anesthesia offers a potential economic advantage by permitting faster changing times. Implantation in GA only should be performed at a special request by the patient or in difficult venous conditions. Georg Thieme Verlag Stuttgart.New York.

  16. A two-microphone noise reduction system for cochlear implant users with nearby microphones. Part II: Performance Evaluation

    OpenAIRE

    Kompis, Martin; Bertram, Matthias; Senn, Pascal; Müller, Joachim; Pelizzone, Marco; Häusler, Rudolf

    2008-01-01

    Users of cochlear implants (auditory aids, which stimulate the auditory nerve electrically at the inner ear) often suffer from poor speech understanding in noise. We evaluate a small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. The system is evaluated in simulated and real, anechoic and reverberant environments. Results from simulations show improvements of 3.4 to 9.3 dB in signa...

  17. Sacroiliac joint stability: Finite element analysis of implant number, orientation, and superior implant length.

    Science.gov (United States)

    Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K

    2018-03-18

    To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System ® ). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results.

  18. Variable-temperature sample system for ion implantation at -192 to +5000C

    International Nuclear Information System (INIS)

    Fuller, C.T.

    1978-04-01

    A variable-temperature sample system based on exchange-gas coupling was developed for ion-implantation use. The sample temperature can be controlled from -192 0 C to +500 0 C with rapid cooling. The system also has provisions for focusing and alignment of the ion beam, electron suppression, temperature monitoring, sample current measuring, and cryo-shielding. Design considerations and operating characteristics are discussed. 5 figures

  19. Advances in the Surgical Management of Articular Cartilage Defects: Autologous Chondrocyte Implantation Techniques in the Pipeline.

    Science.gov (United States)

    Stein, Spencer; Strauss, Eric; Bosco, Joseph

    2013-01-01

    The purpose of this review is to gain insight into the latest methods of articular cartilage implantation (ACI) and to detail where they are in the Food and Drug Administration approval and regulatory process. A PubMed search was performed using the phrase "Autologous Chondrocyte Implantation" alone and with the words second generation and third generation. Additionally, clinicaltrials.gov was searched for the names of the seven specific procedures and the parent company websites were referenced. Two-Stage Techniques: BioCart II uses a FGF2v1 culture and a fibrinogen, thrombin matrix, whereas Hyalograft-C uses a Hyaff 11 matrix. MACI uses a collagen I/III matrix. Cartipatch consists of an agarose-alginate hydrogel. Neocart uses a high-pressure bioreactor for culturing with a type I collagen matrix. ChondroCelect makes use of a gene expression analysis to predict chondrocyte proliferation and has demonstrated significant clinical improvement, but failed to show superiority to microfracture in a phase III trial. One Step Technique: CAIS is an ACI procedure where harvested cartilage is minced and implanted into a matrix for defect filling. As full thickness defects in articular cartilage continue to pose a challenge to treat, new methods of repair are being researched. Later generation ACI has been developed to address the prevalence of fibrocartilage with microfracture and the complications associated with the periosteal flap of first generation ACI such as periosteal hypertrophy. The procedures and products reviewed here represent advances in tissue engineering, scaffolds and autologous chondrocyte culturing that may hold promise in our quest to alter the natural history of symptomatic chondral disease.

  20. Radioactive implants for medical applications; Radioaktive Implantate fuer medizinische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, M.

    2008-07-01

    The long-term success of surgery is often diminished by excessive wound healing, which makes another intervention necessary. Locally applied radionuclides with short range radiation can prevent such benign hyperproliferation. As pure electron emitter with a half-life of 14.3 days and a mean energy of 694.9 keV (E{sub max}=1710.48 keV) {sup 32}P is a suitable radionuclide which can be produced from the stable {sup 31}P by the capture of thermal neutrons (1 x 10{sup 14} /s/cm{sup 2}) in a nuclear reactor. After a typical irradiation time (14 days) the ratio of {sup 32}P to {sup 31}P is 1.4 x 10{sup -5} to 1. Implants made of polymer and/or bioabsorbable material functioning as a carrier of the radioactive emitter allow - as opposed to metallic implants - for new applications for this type of radiotherapy. In this thesis a manufacturing method for previously not available organic, radioactive implants has been developed and a corresponding dosimetry system has been established. By means of ion implantation, {sup 32}P ions with up to 180 keV can be shot some 100 nm deep into organic implant materials. For a typical dose (15 Gy over 7 days, 1 mm distance from the implant) an activity of 75 kBq is needed corresponding to 1.3 x 10{sup 11} {sup 32}P ions. The sputter ion gun, which has been optimized for this application, creates an ion beam with high beam current (> 14 {mu}A P{sup -}) and low emittance (< 4 {pi} mm mrad {radical}(MeV)). Because of the good beam quality also small implants (<1 mm{sup 2}) can be manufactured with high efficiency. The unintentionally co-implanted portion of molecules and nuclides of the same mass (e.g. {sup 31}PH, {sup 16}O{sub 2} and {sup 32}S) could be reduced from approximately 500 to 50 by an improvement of the isotope selection at {sup 32}P beam creation. Hence, in comparison with the best hitherto existing implantation methods, the radiation dose of the implant could be reduced by an order of magnitude. With regard to the beta

  1. Group D. Initiator paper. Implants--peri-implant (hard and soft tissue) interactions in health and disease: the impact of explosion of implant manufacturers.

    Science.gov (United States)

    Ivanovski, Saso

    2015-01-01

    1. The best-documented implants have a threaded solid screw-type design and are manufactured from commercially pure (grade IV) titanium. There is good evidence to support implants ≥ 6 mm in length, and ≥ 3 mm in diameter. 2. Integrity of the seal between the abutment and the implant is important for several reasons, including minimization of mechanical and biological complications and maintaining marginal bone levels. Although the ideal design features of the implant-abutment connection have not been determined, an internal connection, micro-grooves at the implant collar, and horizontal offset of the implant-abutment junction (platform switch) appear to impart favorable properties. 3. Implants with moderately rough implant surfaces provide advantages over machined surfaces in terms of the speed and extent of osseointegration. While the favorable performances of both minimally and moderately rough surfaces are supported by long-term data, moderately rough surfaces provide superior outcomes in compromised sites, such as the posterior maxilla. 4. Although plaque is critical in the progression of peri-implantitis, the disease has a multi-factorial aetiology, and may be influenced by poor integrity of the abutment/implant connection. Iatrogenic factors, such as the introduction of a foreign body. (e.g., cement) below the mucosal margin, can be important contributors. 5. Clinicians should exercise caution when using a particular implant system, ensuring that the implant design is appropriate and supported by scientific evidence. Central to this is access to and participation in quality education on the impact that implant characteristics can have on clinical outcomes. Caution should be exercised in utilizing non-genuine restorative componentry that may lead to a poor implant-abutment fit and subsequent technical and biological complications.

  2. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  3. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  4. Symmetric Encryption Relying on Chaotic Henon System for Secure Hardware-Friendly Wireless Communication of Implantable Medical Systems

    Directory of Open Access Journals (Sweden)

    Taha Belkhouja

    2018-05-01

    Full Text Available Healthcare remote devices are recognized as a promising technology for treating health related issues. Among them are the wireless Implantable Medical Devices (IMDs: These electronic devices are manufactured to treat, monitor, support or replace defected vital organs while being implanted in the human body. Thus, they play a critical role in healing and even saving lives. Current IMDs research trends concentrate on their medical reliability. However, deploying wireless technology in such applications without considering security measures may offer adversaries an easy way to compromise them. With the aim to secure these devices, we explore a new scheme that creates symmetric encryption keys to encrypt the wireless communication portion. We will rely on chaotic systems to obtain a synchronized Pseudo-Random key. The latter will be generated separately in the system in such a way that avoids a wireless key exchange, thus protecting patients from the key theft. Once the key is defined, a simple encryption system that we propose in this paper will be used. We analyze the performance of this system from a cryptographic point of view to ensure that it offers a better safety and protection for patients.

  5. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  6. An economic evaluation of maxillary implant overdentures based on six vs. four implants.

    Science.gov (United States)

    Listl, Stefan; Fischer, Leonhard; Giannakopoulos, Nikolaos Nikitas

    2014-08-18

    The purpose of the present study was to assess the value for money achieved by bar-retained implant overdentures based on six implants compared with four implants as treatment alternatives for the edentulous maxilla. A Markov decision tree model was constructed and populated with parameter estimates for implant and denture failure as well as patient-centred health outcomes as available from recent literature. The decision scenario was modelled within a ten year time horizon and relied on cost reimbursement regulations of the German health care system. The cost-effectiveness threshold was identified above which the six-implant solution is preferable over the four-implant solution. Uncertainties regarding input parameters were incorporated via one-way and probabilistic sensitivity analysis based on Monte-Carlo simulation. Within a base case scenario of average treatment complexity, the cost-effectiveness threshold was identified to be 17,564 € per year of denture satisfaction gained above of which the alternative with six implants is preferable over treatment including four implants. Sensitivity analysis yielded that, depending on the specification of model input parameters such as patients' denture satisfaction, the respective cost-effectiveness threshold varies substantially. The results of the present study suggest that bar-retained maxillary overdentures based on six implants provide better patient satisfaction than bar-retained overdentures based on four implants but are considerably more expensive. Final judgements about value for money require more comprehensive clinical evidence including patient-centred health outcomes.

  7. Three-Dimensional Electroanatomic Mapping System-Enhanced Cardiac Resynchronization Therapy Device Implantation: Results From a Multicenter Registry.

    Science.gov (United States)

    Del Greco, Maurizio; Maines, Massimiliano; Marini, Massimiliano; Colella, Andrea; Zecchin, Massimo; Vitali-Serdoz, Laura; Blandino, Alessandro; Barbonaglia, Lorella; Allocca, Giuseppe; Mureddu, Roberto; Marenna, Biondino; Rossi, Paolo; Vaccari, Diego; Chianca, Roberto; Indiani, Stefano; DI Matteo, Irene; Angheben, Carlo; Zorzi, Alessandro

    2017-01-01

    Cardiac resynchronization therapy (CRT) device implantation guided by an electroanatomic mapping system (EAMS) is an emerging technique that may reduce fluoroscopy and angiography use and provide information on coronary sinus (CS) electrical activation. We evaluated the outcome of the EAMS-guided CRT implantation technique in a multicenter registry. During the period 2011-2014 we enrolled 125 patients (80% males, age 74 [71-77] years) who underwent CRT implantation by using the EnSite system to create geometric models of the patient's cardiac chambers, build activation mapping of the CS, and guide leads positioning. Two hundred and fifty patients undergoing traditional CRT implantation served as controls. Success and complication rates, fluoroscopy and total procedure times in the overall study population and according to center experience were collected. Centers that performed ≥10 were defined as highly experienced. Left ventricular lead implantation was successful in 122 (98%) cases and 242 (97%) controls (P = 0.76). Median fluoroscopy time was 4.1 (0.3-10.4) minutes in cases versus 16 (11-26) minutes in controls (P < 0.001). Coronary sinus angiography was performed in 33 (26%) cases and 208 (83%) controls (P < 0.001). Complications occurred in 5 (4%) cases and 17 (7%) controls (P = 0.28). Median fluoroscopy time (median 11 minutes vs. 3 minutes, P < 0.001) and CS angiography rate (55% vs. 21%, P < 0.001) were significantly higher in low experienced centers, while success rate and complications rate were similar. EAMS-guided CRT implantation proved safe and effective in both high- and low-experienced centers and allowed to reduce fluoroscopy use by ≈75% and angiography rate by ≈70%. © 2016 Wiley Periodicals, Inc.

  8. Implantation doping of GaN

    International Nuclear Information System (INIS)

    Zolper, J.C.

    1996-01-01

    Ion implantation has played an enabling role in the realization of many high performance photonic and electronic devices in mature semiconductor materials systems such as Si and GaAs. This can also be expected to be the case in III-Nitride based devices as the material quality continues to improve. This paper reviews the progress in ion implantation processing of the III-Nitride materials, namely, GaN, AlN, InN and their alloys. Details are presented of the successful demonstrations of implant isolation as well as n- and p-type implantation doping of GaN. Implant doping has required activation annealing at temperatures in excess of 1,000 C. The nature of the implantation induced damage and its response to annealing is addressed using Rutherford Backscattering. Finally, results are given for the first demonstration of a GaN device fabricated using ion implantation doping, a GaN junction field effect transistor (JFET)

  9. Different encapsulation strategies for implanted electronics

    Directory of Open Access Journals (Sweden)

    Winkler Sebastian

    2017-09-01

    Full Text Available Recent advancements in implant technology include increasing application of electronic systems in the human body. Hermetic encapsulation of electronic components is necessary, specific implant functions and body environments must be considered. Additional functions such as wireless communication systems require specialized technical solutions for the encapsulation.

  10. Systemic levels of metallic ions released from orthodontic mini-implants.

    Science.gov (United States)

    de Morais, Liliane Siqueira; Serra, Glaucio Guimarães; Albuquerque Palermo, Elisabete Fernandes; Andrade, Leonardo Rodrigues; Müller, Carlos Alberto; Meyers, Marc André; Elias, Carlos Nelson

    2009-04-01

    Orthodontic mini-implants are a potential source of metallic ions to the human body because of the corrosion of titanium (Ti) alloy in body fluids. The purpose of this study was to gauge the concentration of Ti, aluminum (Al), and vanadium (V), as a function of time, in the kidneys, livers, and lungs of rabbits that had Ti-6Al-4V alloy orthodontic mini-implants placed in their tibia. Twenty-three New Zealand rabbits were randomly divided into 4 groups: control, 1 week, 4 weeks, and 12 weeks. Four orthodontic mini-implants were placed in the left proximal tibia of 18 rabbits. Five control rabbits had no orthodontic mini-implants. After 1, 4, and 12 weeks, the rabbits were killed, and the selected tissues were extracted and prepared for analysis by graphite furnace atomic absorption spectrophotometry. Low amounts of Ti, Al, and V were detectable in the 1-week, 4-weeks, and 12-weeks groups, confirming that release of these metals from the mini-implants occurs, with diffusion and accumulation in remote organs. Despite the tendency of ion release when using the Ti alloy as orthodontic mini-implants, the amounts of metals detected were significantly below the average intake of these elements through food and drink and did not reach toxic concentrations.

  11. Percutaneous implantation of intra-arterial port system for regional drug infusion: results and complications in 110 cases

    International Nuclear Information System (INIS)

    Won, Je Hwan; Lee, Jong Hyuk; Ko, Kyung Hee; Won, Jong Yoon; Park, Sung Il; Lee, Do Yun; Kang, Byung Chul

    2000-01-01

    To investigate the feasibility and complications of a percutaneously implantable port system for regional drug infusion. For intra-arterial drug infusion, a 5.8 or 5-F pediatric venous port system was implanted in 110 patients with hepatocellular carcinoma (n=79), liver metastasis (n=16), gallbladder cancer (n=4), stomach cancer (n=3), pancreatic cancer (n=3), Burger's diseases mellitus (n=2), or lymphoma (n=1). All intra-arterial port implantations were performed percutaneously in an angiographic ward through the common femoral artery (n=98), left subclavian artery (n=10), or left superficial femoral artery (n=2). Complications were evaluated during the follow-up period, which ranged from 21 to 530 (mean, 163) days. The technical success rate for percutaneous implantation of the system was 97.3% (107 of 110 patients). The tips of the port catheter were located in the common hepatic artery (n=34), proper hepatic artery (n=49), right hepatic artery quick resulthepatic artery (n=1), descending aorta at T9 level (n=10), left popliteal artery (n=2), right external iliac artery (n=1), left external iliac artery (n=1), or left deep femoral artery (n=1). Complications were encountered in 24 patients (22.4%), namely chamber site infection (n=7), catheter dislodgement (n=7), catheter occlusion (n=3), migration of coil (n=2), disconnection between chamber and catheter (n=1), kinking of catheter (n=1), arterial occlusion (n=1), necrosis of overlying skin (n=1), and leakage around port chamber (n=1). Outcomes of complications included removal of port systems or cessation of therapy in 12 cases (11.2%), correction of catheter location using a guide wire in five (4.7%), thrombolysis with urokinase in three (2.8%), and straightening using a snare in one (0.9%). In three patients, the port system was used without reintervention. Percutaneous implantation of an intra-arterial port system showed a high technical success rate and a low rate of serious complications. The method may be

  12. Local and systemic changes associated with long-term, percutaneous, static implantation with titanium alloys in rhesus macaques (Macaca mulatta)

    Energy Technology Data Exchange (ETDEWEB)

    Frydman, Galit F.; Marini, Robert P.; Bakthavatchalu, Vasudevan; Biddle, Kathleen; Muthupalani, Sureshkumar; Vanderburg, Charles R.; Lai, Barry; Bendapudi, Pavan K.; Tompkins, Ronald G.; Fox, James G.

    2017-04-01

    Metal alloys are frequently used as implant materials in veterinary medicine. Recent studies suggest that many types of metal alloys may induce both local and systemic inflammatory responses. In this study, 37 rhesus macaques with long-term skull-anchored percutaneous titanium alloy implants (0-14 years duration) were evaluated for changes in their hematology, coagulation and serum chemistry profiles. Negative controls (n=28) did not have implants. All of the implanted animals were on IACUC-approved protocols and were not implanted for the purpose of this study. Animals with implants had significantly higher plasma D-dimer and lower antithrombin III concentrations compared with nonimplanted animals (p-values < 0.05). Additionally, animals with implants had significantly higher globulin, and lower albumin and calcium concentrations compared with nonimplanted animals (p-values < 0.05). Many of these changes were positively correlated with duration of implantation as well as the number of implants. Chronic bacterial infection was observed on the skin around many of the implant sites, and within deeper tissues. Representative histopathology around the implant site of two implanted animals revealed chronic suppurative to pyogranulomatous inflammation extending from the skin to the dura mater. X-ray fluorescence microscopy of tissue biopsies from the implant site of the same two animals revealed significant increases in free metal ions within the tissue, including titanium and iron. Free metal ions persisted in the tissues up to 6 months postexplant. These results suggest that long-term skull-anchored percutaneous titanium alloy implants results in localized inflammation, chronic infection, and leaching of metal ions into local tissues.

  13. Stent implantation into the tracheo-bronchial system in rabbits: histopathologic sequelae in bare metal vs. drug-eluting stents.

    Science.gov (United States)

    Sigler, Matthias; Klötzer, Julia; Quentin, Thomas; Paul, Thomas; Möller, Oliver

    2015-12-01

    Stent implantation into the tracheo-bronchial system may be life-saving in selected pediatric patients with otherwise intractable stenosis of the upper airways. Following implantation, significant tissue proliferation may occur, requiring re-interventions. We sought to evaluate the effect of immunosuppressive coating of the stents on the extent of tissue proliferation in an animal model. Bare metal and sirolimus-coated stents (Bx Sonic and Cypher Select, Johnson & Johnson, Cordis) were implanted into non-stenotic lower airways of New Zealand white rabbits (weight 3.1 to 4.8 kg). Three stents with sirolimus coating and six bare metal stents could be analyzed by means of histology and immunohistochemistry 12 months after implantation. On a macroscopic evaluation, all stents were partially covered with a considerable amount of whitish tissue. Histologically, these proliferations contained fiber-rich connective tissue and some fibromuscular cells without significant differences between both stent types. The superficial tissue layer was formed by typical respiratory epithelium and polygonal cells. Abundant lymphocyte infiltrations and moderate granulocyte infiltrations were found in both groups correspondingly, whereas foreign-body reaction was more pronounced around sirolimus-eluting stents. After stent implantation in the tracheo-bronchial system of rabbits, we found tissue reactions comparable to those seen after stent implantation into the vascular system. There was no difference between coated and uncoated stents with regard to quality and quantity of tissue proliferation. We found, however, a significantly different inflammatory reaction with a more pronounced foreign-body reaction in sirolimus-coated stents. In our small series, drug-eluting stents did not exhibit any benefit over bare metal stents in an experimental setting.

  14. A touch probe method of operating an implantable RFID tag for orthopedic implant identification.

    Science.gov (United States)

    Liu, Xiaoyu; Berger, J Lee; Ogirala, Ajay; Mickle, Marlin H

    2013-06-01

    The major problem in operating an implantable radio-frequency identification (RFID) tag embedded on an orthopedic implant is low efficiency because of metallic interference. To improve the efficiency, this paper proposes a method of operating an implantable passive RFID tag using a touch probe at 13.56 MHz. This technology relies on the electric field interaction between two pairs of electrodes, one being a part of the touch probe placed on the surface of tissue and the other being a part of the tag installed under the tissue. Compared with using a conventional RFID antenna such as a loop antenna, this method has a better performance in the near field operation range to reduce interference with the orthopedic implant. Properly matching the touch probe and the tag to the tissue and the implant reduces signal attenuation and increases the overall system efficiency. The experiments have shown that this method has a great performance in the near field transcutaneous operation and can be used for orthopedic implant identification.

  15. Design and optimization of a 3-coil resonance-based wireless power transfer system for biomedical implants

    KAUST Repository

    Yi, Ying

    2014-09-01

    This paper presents a resonance-based wireless power transfer system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. We theoretically analyzed the system and characterized it by measuring its inductance, self-resonant frequency, and quality factor Q. In our resonance-based wireless power transfer prototype, we proposed a 3-coil system, using two 15-mm radius implantable coils, with a resonance frequency of 6.76MHz. This system can effectively transfer power for a distance of up to 50mm. Moreover, our proposed 3-coil system can achieve a high Q-factor and has a comparable power transfer efficiency (PTE) to previously reported works about 3-coil and 4-coil systems. The experimental PTE can achieve 82.4% at a separation distance of 20mm and more than 10% PTE at a distance of 40mm.

  16. Design and optimization of a 3-coil resonance-based wireless power transfer system for biomedical implants

    KAUST Repository

    Yi, Ying; Buttner, Ulrich; Fan, Yiqiang; Foulds, Ian G.

    2014-01-01

    This paper presents a resonance-based wireless power transfer system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. We theoretically analyzed the system and characterized it by measuring its inductance, self-resonant frequency, and quality factor Q. In our resonance-based wireless power transfer prototype, we proposed a 3-coil system, using two 15-mm radius implantable coils, with a resonance frequency of 6.76MHz. This system can effectively transfer power for a distance of up to 50mm. Moreover, our proposed 3-coil system can achieve a high Q-factor and has a comparable power transfer efficiency (PTE) to previously reported works about 3-coil and 4-coil systems. The experimental PTE can achieve 82.4% at a separation distance of 20mm and more than 10% PTE at a distance of 40mm.

  17. Automated dental implantation using image-guided robotics: registration results.

    Science.gov (United States)

    Sun, Xiaoyan; McKenzie, Frederic D; Bawab, Sebastian; Li, Jiang; Yoon, Yongki; Huang, Jen-K

    2011-09-01

    One of the most important factors affecting the outcome of dental implantation is the accurate insertion of the implant into the patient's jaw bone, which requires a high degree of anatomical accuracy. With the accuracy and stability of robots, image-guided robotics is expected to provide more reliable and successful outcomes for dental implantation. Here, we proposed the use of a robot for drilling the implant site in preparation for the insertion of the implant. An image-guided robotic system for automated dental implantation is described in this paper. Patient-specific 3D models are reconstructed from preoperative Cone-beam CT images, and implantation planning is performed with these virtual models. A two-step registration procedure is applied to transform the preoperative plan of the implant insertion into intra-operative operations of the robot with the help of a Coordinate Measurement Machine (CMM). Experiments are carried out with a phantom that is generated from the patient-specific 3D model. Fiducial Registration Error (FRE) and Target Registration Error (TRE) values are calculated to evaluate the accuracy of the registration procedure. FRE values are less than 0.30 mm. Final TRE values after the two-step registration are 1.42 ± 0.70 mm (N = 5). The registration results of an automated dental implantation system using image-guided robotics are reported in this paper. Phantom experiments show that the practice of robot in the dental implantation is feasible and the system accuracy is comparable to other similar systems for dental implantation.

  18. Spectral-Temporal Modulated Ripple Discrimination by Children With Cochlear Implants.

    Science.gov (United States)

    Landsberger, David M; Padilla, Monica; Martinez, Amy S; Eisenberg, Laurie S

    A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. It is likely that the auditory system of early implanted cochlear implant users is fundamentally different than postlingually implanted adults. The purpose of this study is to compare the basic psychophysical capabilities and limitations of these two populations on a spectral resolution task to determine potential effects of early deprivation and plasticity. Performance on a spectral resolution task (Spectral-temporally Modulated Ripple Test [SMRT]) was measured for 20 bilaterally implanted, prelingually deafened children (between 5 and 13 years of age) and 20 hearing children within the same age range. Additionally, 15 bilaterally implanted, postlingually deafened adults, and 10 hearing adults were tested on the same task. Cochlear implant users (adults and children) were tested bilaterally, and with each ear alone. Hearing listeners (adults and children) were tested with the unprocessed SMRT and with a vocoded version that simulates an 8-channel cochlear implant. For children with normal hearing, a positive correlation was found between age and SMRT score for both the unprocessed and vocoded versions. Older hearing children performed similarly to hearing adults in both the unprocessed and vocoded test conditions. However, for children with cochlear implants, no significant relationship was found between SMRT score and chronological age, age at implantation, or years of implant experience. Performance by children with cochlear implants was poorer than performance by cochlear implanted adults. It was also found that children implanted sequentially tended to have better scores with the first implant compared with the second implant. This difference was not

  19. Maxillary Three-Implant Overdentures Opposing Mandibular Two-Implant Overdentures: 10-Year Surgical Outcomes of a Randomized Controlled Trial.

    Science.gov (United States)

    Ma, Sunyoung; Tawse-Smith, Andrew; De Silva, Rohana K; Atieh, Momen A; Alsabeeha, Nabeel H M; Payne, Alan G T

    2016-06-01

    The surgical placement of four maxillary implants for overdentures may not be obligatory when opposing mandibular two-implant overdentures. To determine 10-year surgical outcomes and implant success of three narrow diameter implants in edentulous maxillae with conventional loading. Forty participants with mandibular two-implant overdentures were randomly allocated for surgery for maxillary overdentures. Using osteotomes, three implants of similar systems were placed with a one-stage procedure and 12-week loading with splinted and unsplinted prosthodontic designs. Marginal bone and stability measurements were done at surgery, 12 weeks, 1-, 2-, 5-, 7-, 10 years. One hundred seventeen implants were placed in 39 participants, with 35 being seen at 1 year; 29 at 2 years; 28 at 5 years; 26 at 7 years; and 23 (59%) at 10 years. Marginal bone loss was 1.35 mm between surgery and 12 weeks; 0.36 mm between 12 weeks and 1 year; 0.48 mm between 1 and 5 years; and 0.22 mm between 5 and 10 years. Implant stability quotients were 56.05, 57.54, 60.88, 58.80, 61.17 at surgery, 12 weeks, 1 year, 5 years, and 10 years. Four-field tables by implant showed success rates of 82% at 1 year; 69.2% at 2 years; 66.7% at 5 years; 61.5% at 7 years; 51.3% at 10 years. Data showed no differences between surgical technique, systems, or prosthodontic designs. Surgical placement with osteotomes of three narrow diameter implants for maxillary overdentures, opposing mandibular two-implant overdentures, is an acceptable approach, subject to strict patient selection. Implant success is independent of prosthodontic design. © 2015 Wiley Periodicals, Inc.

  20. New Petrology, Mineral Chemistry and Stable MG Isotope Compositions of an Allende CAI: EK-459-7-2

    Science.gov (United States)

    Jeffcoat, C. R.; Kerekgyarto, A. G.; Lapen, T. J.; Righter, M.; Simon, J. I.; Ross, D. K.

    2016-01-01

    Calcium-aluminum-rich inclusions (CAIs) are the key to understanding physical and chemical conditions in the nascent solar nebula. These inclusions have the oldest radiometric ages of solar system materials and are composed of phases that are predicted to condense early from a gas of solar composition. Thus, their chemistry and textures record conditions and processes in the earliest stages of development of the solar nebula. Type B inclusions are typically larger and more coarse grained than other types with substantial evidence that many of them were at least partially molten. Type B inclusions are further subdivided into Type B1 (possess thick melilite mantle) and Type B2 (lack melilite mantle). Despite being extensively studied, the origin of the melilite mantles of Type B1 inclusions remains uncertain. We present petrologic and chemical data for a Type B inclusion, EK-459-7-2, that bears features found in both Type B1 and B2 inclusions and likely represents an intermediate between the two types. Detailed studies of more of these intermediate objects may help to constrain models for Type B1 rim formation.

  1. Reliable and energy-efficient communications for wireless biomedical implant systems.

    Science.gov (United States)

    Ntouni, Georgia D; Lioumpas, Athanasios S; Nikita, Konstantina S

    2014-11-01

    Implant devices are used to measure biological parameters and transmit their results to remote off-body devices. As implants are characterized by strict requirements on size, reliability, and power consumption, applying the concept of cooperative communications to wireless body area networks offers several benefits. In this paper, we aim to minimize the power consumption of the implant device by utilizing on-body wearable devices, while providing the necessary reliability in terms of outage probability and bit error rate. Taking into account realistic power considerations and wireless propagation environments based on the IEEE P802.l5 channel model, an exact theoretical analysis is conducted for evaluating several communication scenarios with respect to the position of the wearable device and the motion of the human body. The derived closed-form expressions are employed toward minimizing the required transmission power, subject to a minimum quality-of-service requirement. In this way, the complexity and power consumption are transferred from the implant device to the on-body relay, which is an efficient approach since they can be easily replaced, in contrast to the in-body implants.

  2. Impact of systemic diseases on oral health related quality of life after implant-prosthodontic rehabilitation

    Directory of Open Access Journals (Sweden)

    Tina Pretnar

    2014-08-01

    Full Text Available Background: Implant-prosthodontic rehabilitation improves oral health related quality of life (OHRQoL, but the presence of systemic diseases can also affect the well-being of an individual.The study was carried out to determine the relationship between systemic diseases and OHRQoL after implant-prosthodontic rehabilitation on the basis of psychometric testing by a standardized questionnaire »Oral Health Impact Profile« (OHIP.Methods: 130 patients, who received one to eight Ankylos® implants (on average 2.6 ± 1.8 were included in this retrospective study in which all aspects of the OHRQoL construct were evaluated with a Slovenian version of the OHIP questionnaire. Data on all present systemic diseases were obtained from the existing health records. Dental status and dental restorations were identified on the basis of orthopantomographic images.Results: The majority of subjects had a cardiovascular disease (N = 37; 28.5 %, followed by a headache (N = 15, 11.5 %, allergies and asthma (n = 13, 10 %, and a rheumatic disease (N = 11, 8.5 %. Only osteoporosis was statistically significantly related to OHRQoL after implant-prosthodontic rehabilitation (p = 0.024. The best multiple linear regression model for the summary score for the questionnaire »Oral Health Impact Profile« for Slovenia (OHIP, and taking into account gender and age as confounding factors, included the number of remaining teeth and the presence of osteoporosis (p = 0.003, adjusted R2 = 0.104.Conclusions: The total number of remaining teeth in the oral cavity (p = 0.031, the presence of osteoporosis (p = 0.024, and taking into account the subject’s gender and age, are the most important clinical factors that affect the functioning of the SGS as well as psychosocial behavior of the patients after an implant-prosthodontic rehabilitation (adjusted R2 = 0.104. Other systemic diseases (cardiovascular disease, headache, allergies and

  3. Determining Threshold Distance Providing Less Interference for Wireless Medical Implant Communication Systems in Coexisting Environments under Shadow Fading Conditions

    Directory of Open Access Journals (Sweden)

    Selman KULAÇ

    2017-08-01

    Full Text Available Important interference problems will be able to be encountered especially close areas to the hospitals where wireless implantable medical systems' communication traffic occurs heavily in near future. It is possible that these interferences could cause wireless implant devices to malfunction and harmful effects on patients. In this study, it is proposed to determine threshold distance in order to get less interference for wireless implantable medical systems under shadow fading conditions where MICS band and MetAids band users coexist intensely simultaneously. In this method, threshold power according to the \\cite{FCC} is pulled down by adding extra distance margin in order to minimize the interference effects to the MICS systems using confidence interval calculations. Because received signal strength just below the monitoring threshold power according to the \\cite{FCC} brings about much more interferences for the MICS systems even if listen-before-talk technique is applied.

  4. Impact of Different Surgeons on Dental Implant Failure.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    To assess the influence of several factors on the prevalence of dental implant failure, with special consideration of the placement of implants by different dental surgeons. This retrospective study is based on 2,670 patients who received 10,096 implants at one specialist clinic. Only the data of patients and implants treated by surgeons who had inserted a minimum of 200 implants at the clinic were included. Kaplan-Meier curves were stratified with respect to the individual surgeon. A generalized estimating equation (GEE) method was used to account for the fact that repeated observations (several implants) were placed in a single patient. The factors bone quantity, bone quality, implant location, implant surface, and implant system were analyzed with descriptive statistics separately for each individual surgeon. A total of 10 surgeons were eligible. The differences between the survival curves of each individual were statistically significant. The multivariate GEE model showed the following variables to be statistically significant: surgeon, bruxism, intake of antidepressants, location, implant length, and implant system. The surgeon with the highest absolute number of failures was also the one who inserted the most implants in sites of poor bone and used turned implants in most cases, whereas the surgeon with the lowest absolute number of failures used mainly modern implants. Separate survival analyses of turned and modern implants stratified for the individual surgeon showed statistically significant differences in cumulative survival. Different levels of failure incidence could be observed between the surgeons, occasionally reaching significant levels. Although a direct causal relationship could not be ascertained, the results of the present study suggest that the surgeons' technique, skills, and/or judgment may negatively influence implant survival rates.

  5. An Evaluation of the Cognitive and Affective Performance of an Integrated Set of CAI Materials in the Principles of Macroeconomics. Studies in Economic Education, No. 4.

    Science.gov (United States)

    Daellenbach, Lawrence A.; And Others

    The purpose of this study was to determine the effect of computer assisted instruction (CAI) on the cognitive and affective development of college students enrolled in a principles of macroeconomics course. The hypotheses of the experiment were stated as follows: In relation to the traditional principles course, the experimental treatment will…

  6. Dose perturbation in the presence of metallic implants: treatment planning system versus Monte Carlo simulations

    International Nuclear Information System (INIS)

    Wieslander, Elinore; Knoeoes, Tommy

    2003-01-01

    An increasing number of patients receiving radiation therapy have metallic implants such as hip prostheses. Therefore, beams are normally set up to avoid irradiation through the implant; however, this cannot always be accomplished. In such situations, knowledge of the accuracy of the used treatment planning system (TPS) is required. Two algorithms, the pencil beam (PB) and the collapsed cone (CC), are implemented in the studied TPS. Comparisons are made with Monte Carlo simulations for 6 and 18 MV. The studied materials are steel, CoCrMo, Orthinox(a stainless steel alloy and registered trademark of Stryker Corporation), TiAlV and Ti. Monte Carlo simulated depth dose curves and dose profiles are compared to CC and PB calculated data. The CC algorithm shows overall a better agreement with Monte Carlo than the PB algorithm. Thus, it is recommended to use the CC algorithm to get the most accurate dose calculation both for the planning target volume and for tissues adjacent to the implants when beams are set up to pass through implants

  7. Macro design morphology of endosseous dental implants.

    Science.gov (United States)

    Sahiwal, Indira G; Woody, Ronald D; Benson, Byron W; Guillen, Guillermo E

    2002-05-01

    The identification of dental implant bodies in patients without available records is a considerable problem due to increased patient mobility and to the large number of implant systems with different designs. The purpose of this study was to document the designs of selected implants to help clinicians identify these implants from their radiographic images. More than 50 implant manufacturers were contacted and asked to provide implants with dimensions as close as possible to 3.75 mm (diameter) x 10 mm (length). Forty-four implants were donated, separated into threaded and non-threaded categories, and further sorted into tapered and non-tapered categories. The implants were examined visually, and features on the entire circumference and length of each implant were recorded and categorized as coronal, midbody, or apical. A series of tables describe the 44 implants according to coronal, midbody, and apical features. The results of this project offer dentists basic knowledge of the design of selected dental implants. Such knowledge can aid the radiographic identification of these implants.

  8. Retention system for implant-supported dentures used by brazilian dentists who work in implant dentistry

    OpenAIRE

    Saturnino Aparecido Ramalho; Fábio Pontes Dantas

    2010-01-01

    Objective: To provide the dentists with support in the choice of the cement or screw type of retention for implant-supported dentures, according to the patient’s problem. Methods: An opinion questionnaire was applied to a sample of 468 participants, all dentists working in the field of Implant Dentistry, of whom 272 (58.1%) participated in the 4th International Congress of Osseointegration of APCD, held in São Paulo (SP) from 6 to 9 May 2004, 119 (25.4%) participated in the 2nd International ...

  9. Irradiation influence on Mylar and Makrofol induced by argon ions in a plasma immersion ion implantation system

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, A. [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); El-Saftawy, A.A., E-mail: aama1978@yahoo.com [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Aal, S.A. Abd El [Central Lab. for Elemental & Isotopic Analysis, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Ghazaly, M. El [Physiology Department, College of Medicine, Taif University, P.O. 888, Taif (Saudi Arabia); Physics Department, Faculty of Science, Zagazig University, P.O. 44519, Zagazig (Egypt)

    2015-08-30

    Highlights: • A home-built plasma immersion ion implantation system was tested in modifying surfaces. • Wettability modifications within the energy range 10 keV implantation are not investigated elsewhere, up to our knowledge. • The wettability of Mylar and Makrofol surface was enhanced by the dual effect of ion implantation and plasma treatment. • The improved wettability was found to depend on both surface roughness and chemistry. • The adhesive bonding and surface energy of the polymers are improved. - Abstract: Mylar and Makrofol polycarbonate polymers were irradiated by Ar ions in a plasma immersion ion implantation (PIII) system. The surface wettability of both polymers was investigated by employing the contact angle method. The measured contact angles were found to depend on the surface layer properties. Good wetting surfaces were found to depend not only on surface roughness but also on its chemistry that analyzed by Fourier transform infrared (FTIR) spectroscopy. Surfaces topography and roughness was investigated and correlated to their surface energy which studied with the aid of acid-base model for evaluating the improvement of surface wettability after irradiation. PIII improves polymers surface properties efficiently in a controllable way.

  10. Diagnostic Principles of Peri-Implantitis: a Systematic Review and Guidelines for Peri-Implantitis Diagnosis Proposal

    Directory of Open Access Journals (Sweden)

    Ausra Ramanauskaite

    2016-09-01

    Full Text Available Objectives: To review and summarize the literature concerning peri-implantitis diagnostic parameters and to propose guidelines for peri-implantitis diagnosis. Material and Methods: An electronic literature search was conducted of the MEDLINE (Ovid and EMBASE databases for articles published between 2011 and 2016. Sequential screening at the title/abstract and full-text levels was performed. Systematic reviews/guidelines of consensus conferences proposing classification or suggesting diagnostic parameters for peri-implantitis in the English language were included. The review was recorded on PROSPERO system with the code CRD42016033287. Results: The search resulted in 10 articles that met the inclusion criteria. Four were papers from consensus conferences, two recommended diagnostic guidelines, three proposed classification of peri-implantitis, and one suggested an index for implant success. The following parameters were suggested to be used for peri-implantitis diagnosis: pain, mobility, bleeding on probing, probing depth, suppuration/exudate, and radiographic bone loss. In all of the papers, different definitions of peri-implantitis or implant success, as well as different thresholds for the above mentioned clinical and radiographical parameters, were used. Current evidence rationale for the diagnosis of peri-implantitis and classification based on consecutive evaluation of soft-tissue conditions and the amount of bone loss were suggested. Conclusions: Currently there is no single uniform definition of peri-implantitis or the parameters that should be used. Rationale for diagnosis and prognosis of peri-implantitis as well as classification of the disease is proposed.

  11. [Technical feasibility of the implantation of a monorail stent system into the renal arteries without pre-dilatation].

    Science.gov (United States)

    Neumann, C; Gschwendtner, M; Karnel, F; Mair, J; Dorffner, G; Dorffner, R

    2005-01-01

    To evaluate the technical feasibility of the implantation of the monorail RX Herculink system into the renal arteries without pre-dilatation. Forty-two patients (mean age 71 years) from four centers with a total of 44 renal artery stenoses underwent implantation of the RX Herculink stent. The mean grade of the stenosis was 83.8 %, the mean length 7.5 mm. The stenoses were ostial in 38 cases and in immediate proximity to the ostium in 6 cases. The mean follow-up-period was 57 weeks (24 - 176 weeks). In 42 cases, the implantation was successful without pre-dilatation. In 2 cases, pre-dilatation was carried out. In none of the cases, detachment of the stent from the balloon was observed. In one stenosis with a length of 17 mm, implantation of two stents was performed. In 9 cases, post-dilatation with a larger balloon or higher balloon pressure was necessary. Residual stenoses exceeding 30 % were not observed. Two patients developed local bleeding at the puncture site. During the follow-up, restenoses were observed in 5 stents after 26 to 126 weeks, which necessitated a second intervention in 3 cases (PTA in 2 cases, re-stenting in 1 case). The primary patency rate after 6 and 12 months was 0.92 +/- 0.056 according to Kaplan-Meier, the secondary patency rate after 6 and 12 months was 1.0 +/- 0.0. Implantation of the RX Herculink stent system into the renal arteries without pre-dilatation is technically feasible and safe. Even without pre-dilatation, the stent-system can be advanced through the stenosis without detachment. The complication rate is low. Our clinical results are comparable to previous studies.

  12. Laser-Modified Surface Enhances Osseointegration and Biomechanical Anchorage of Commercially Pure Titanium Implants for Bone-Anchored Hearing Systems

    Science.gov (United States)

    Omar, Omar; Simonsson, Hanna; Palmquist, Anders; Thomsen, Peter

    2016-01-01

    Osseointegrated implants inserted in the temporal bone are a vital component of bone-anchored hearing systems (BAHS). Despite low implant failure levels, early loading protocols and simplified procedures necessitate the application of implants which promote bone formation, bone bonding and biomechanical stability. Here, screw-shaped, commercially pure titanium implants were selectively laser ablated within the thread valley using an Nd:YAG laser to produce a microtopography with a superimposed nanotexture and a thickened surface oxide layer. State-of-the-art machined implants served as controls. After eight weeks’ implantation in rabbit tibiae, resonance frequency analysis (RFA) values increased from insertion to retrieval for both implant types, while removal torque (RTQ) measurements showed 153% higher biomechanical anchorage of the laser-modified implants. Comparably high bone area (BA) and bone-implant contact (BIC) were recorded for both implant types but with distinctly different failure patterns following biomechanical testing. Fracture lines appeared within the bone ~30–50 μm from the laser-modified surface, while separation occurred at the bone-implant interface for the machined surface. Strong correlations were found between RTQ and BIC and between RFA at retrieval and BA. In the endosteal threads, where all the bone had formed de novo, the extracellular matrix composition, the mineralised bone area and osteocyte densities were comparable for the two types of implant. Using resin cast etching, osteocyte canaliculi were observed directly approaching the laser-modified implant surface. Transmission electron microscopy showed canaliculi in close proximity to the laser-modified surface, in addition to a highly ordered arrangement of collagen fibrils aligned parallel to the implant surface contour. It is concluded that the physico-chemical surface properties of laser-modified surfaces (thicker oxide, micro- and nanoscale texture) promote bone bonding

  13. Miniature Coplanar Implantable Antenna on Thin and Flexible Platform for Fully Wireless Intracranial Pressure Monitoring System

    Directory of Open Access Journals (Sweden)

    M. Waqas A. Khan

    2017-01-01

    Full Text Available Minimally invasive approach to intracranial pressure monitoring is desired for long-term diagnostics. The monitored pressure is transmitted outside the skull through an implant antenna. We present a new miniature (6 mm × 5 mm coplanar implant antenna and its integration on a sensor platform to establish a far-field data link for the sensor readout at distances of 0.5 to 1 meter. The implant antenna was developed using full-wave electromagnetic simulator and measured in a liquid phantom mimicking the dielectric properties of the human head. It achieved impedance reflection coefficient better than −10 dB from 2.38 GHz to 2.54 GHz which covers the targeted industrial, scientific, and medical band. Experiments resulted in an acceptable peak gain of approximately −23 dBi. The implant antenna was submerged in the liquid phantom and interfaced to a 0.5 mW voltage controlled oscillator. To verify the implant antenna performance as a part of the ICP monitoring system, we recorded the radiated signal strength using a spectrum analyzer. Using a half-wavelength dipole as the receiving antenna, we captured approximately −58.7 dBm signal at a distance of 1 m from the implant antenna which is well above for the reader with sensitivity of −80 dBm.

  14. Stress Distribution in Single Dental Implant System: Three-Dimensional Finite Element Analysis Based on an In Vitro Experimental Model.

    Science.gov (United States)

    Rezende, Carlos Eduardo Edwards; Chase-Diaz, Melody; Costa, Max Doria; Albarracin, Max Laurent; Paschoeto, Gabriela; Sousa, Edson Antonio Capello; Rubo, José Henrique; Borges, Ana Flávia Sanches

    2015-10-01

    This study aimed to analyze the stress distribution in single implant system and to evaluate the compatibility of an in vitro model with finite element (FE) model. The in vitro model consisted of Brånemark implant; multiunit set abutment of 5 mm height; metal-ceramic screw-retained crown, and polyurethane simulating the bone. Deformations were recorded in the peri-implant region in the mesial and distal aspects, after an axial 300 N load application at the center of the occlusal aspect of the crown, using strain gauges. This in vitro model was scanned with micro CT to design a three-dimensional FE model and the strains in the peri-implant bone region were registered to check the compatibility between both models. The FE model was used to evaluate stress distribution in different parts of the system. The values obtained from the in vitro model (20-587 με) and the finite element analysis (81-588 με) showed agreement among them. The highest stresses because of axial and oblique load, respectively were 5.83 and 40 MPa for the cortical bone, 55 and 1200 MPa for the implant, and 80 and 470 MPa for the abutment screw. The FE method proved to be effective for evaluating the deformation around single implant. Oblique loads lead to higher stress concentrations.

  15. Intra- and intersubject comparison of cochlear implant systems using the Esprit and the Tempo+ behind-the-ear speech processor.

    Science.gov (United States)

    Kompis, Martin; Jenk, Martin; Vischer, Mattheus W; Seifert, Eberhard; Häusler, Rudolf

    2002-12-01

    A patient with bilateral profound deafness was implanted with a Nucleus CI24M cochlear implant (CI) and used an Esprit behind-the-ear (BTE) speech processor. Thirteen months later, the implant had to be removed because of a cholesteatoma. As the same electrode could not be reinserted, a Medel combi40s CI was implanted in the same ear, and the patient used a Tempo+ BTE processor. After 1 year of use of the Combi40s/Tempo+ system, speech recognition was better and was rated better subjectively than with the CI24M/Esprit system. Speech recognition and subjective ratings were also assessed for two matched groups of nine CI users each, using either an Esprit or a Tempo+ processor. On average, speech recognition scores were higher for the group of Tempo+ users, but the difference was not statistically significant. Users of the Esprit processors rated their device higher in terms of cosmetic appearance and comfort of wearing.

  16. Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck.

    Science.gov (United States)

    Liu, Yang; Wang, Jiawei

    2017-11-01

    To review the influences and clinical implications of micro-gap and micro-motion of implant-abutment interface on marginal bone loss around the neck of implant. Literatures were searched based on the following Keywords: implant-abutment interface/implant-abutment connection/implant-abutment conjunction, microgap, micromotion/micromovement, microleakage, and current control methods available. The papers were then screened through titles, abstracts, and full texts. A total of 83 studies were included in the literature review. Two-piece implant systems are widely used in clinics. However, the production error and masticatory load result in the presence of microgap and micromotion between the implant and the abutment, which directly or indirectly causes microleakage and mechanical damage. Consequently, the degrees of microgap and micromotion further increase, and marginal bone absorption finally occurs. We summarize the influences of microgap and micromotion at the implant-abutment interface on marginal bone loss around the neck of the implant. We also recommend some feasible methods to reduce their effect. Clinicians and patients should pay more attention to the mechanisms as well as the control methods of microgap and micromotion. To reduce the corresponding detriment to the implant marginal bone, suitable Morse taper or hybrid connection implants and platform switching abutments should be selected, as well as other potential methods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Aspects of an automatic system of implants of radioactive seeds and anatomic object simulator for tests in prostate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Leonardo S.M.; Braga, Viviane V.B.; Campos, Tarcísio P. R. de, E-mail: leonardosantiago.lsms@gmail.com, E-mail: vitoriabraga06@gmail.com, E-mail: tprcampos@yahoo.com.br [Universidade Federal de Minas Gerais (PCTN/UFMG), Belo Horizonte (Brazil). Pós-Graduação em Ciências e Técnicas Nucleares. Departamento de Engenharia Nuclear

    2017-07-01

    This work presents the state of the art of the research and development of an automatic radioactive seed implantation system (PSIS). PSIS may assist in the procedure of testing permanent implants in the prostate. These tests will be important in measurements of absorbed doses in the pelvic structures, involving the organs and tissues at risk to improve planning, seed positioning and dosimetry. The automated Prostate Seed Implant System (PSIS) has been designed to meet operational needs, which offers the freedom of positioning of the brachytherapy needle within the treatment area and ensures repeatability and fidelity to the planned treatment. Both the ultrasound probe and the seed implant needle are driven by step motors, Atmega microcontroller, bearings, aluminum shafts and a GUI (Graphical User Interface). Movement of both the probe and the needle holder was performed by fixed spindle on a threaded rod rushing to the step motors by a coupling. The step motors used to move the system consist of step motors used in CNC (Computer Numeric Control) machine. The choice of these engines occurred due to the precision in the movements that can be obtained with these types of motors. The ultrasound probe serves to help, through the images acquired during the longitudinal movement, to monitor the application of the seeds. The parts that make up the system infrastructure were made of aluminum and translucent acrylic and cylindrical aluminum bars of different diameters. All these pieces were fixed and adjusted trough screws, washers, nuts and adhesive to metal, composing the final prototype of the PSIS. The project was developed and the PSIS prototype was assembled. The prototype presented acceptable operating characteristics for prostate implants. The advantage of this system is the automation of the application that provides an accurate positioning and movement of both probe and seed application. In addition to this study, seeds implantation tests will be performed, and

  18. Aspects of an automatic system of implants of radioactive seeds and anatomic object simulator for tests in prostate brachytherapy

    International Nuclear Information System (INIS)

    Silva, Leonardo S.M.; Braga, Viviane V.B.; Campos, Tarcísio P. R. de

    2017-01-01

    This work presents the state of the art of the research and development of an automatic radioactive seed implantation system (PSIS). PSIS may assist in the procedure of testing permanent implants in the prostate. These tests will be important in measurements of absorbed doses in the pelvic structures, involving the organs and tissues at risk to improve planning, seed positioning and dosimetry. The automated Prostate Seed Implant System (PSIS) has been designed to meet operational needs, which offers the freedom of positioning of the brachytherapy needle within the treatment area and ensures repeatability and fidelity to the planned treatment. Both the ultrasound probe and the seed implant needle are driven by step motors, Atmega microcontroller, bearings, aluminum shafts and a GUI (Graphical User Interface). Movement of both the probe and the needle holder was performed by fixed spindle on a threaded rod rushing to the step motors by a coupling. The step motors used to move the system consist of step motors used in CNC (Computer Numeric Control) machine. The choice of these engines occurred due to the precision in the movements that can be obtained with these types of motors. The ultrasound probe serves to help, through the images acquired during the longitudinal movement, to monitor the application of the seeds. The parts that make up the system infrastructure were made of aluminum and translucent acrylic and cylindrical aluminum bars of different diameters. All these pieces were fixed and adjusted trough screws, washers, nuts and adhesive to metal, composing the final prototype of the PSIS. The project was developed and the PSIS prototype was assembled. The prototype presented acceptable operating characteristics for prostate implants. The advantage of this system is the automation of the application that provides an accurate positioning and movement of both probe and seed application. In addition to this study, seeds implantation tests will be performed, and

  19. System overview of the fully implantable destination therapy--ReinHeart-total artificial heart.

    Science.gov (United States)

    Pelletier, Benedikt; Spiliopoulos, Sotirios; Finocchiaro, Thomas; Graef, Felix; Kuipers, Kristin; Laumen, Marco; Guersoy, Dilek; Steinseifer, Ulrich; Koerfer, Reiner; Tenderich, Gero

    2015-01-01

    Owing to the lack of suitable allografts, the demand for long-term mechanical circulatory support in patients with biventricular end-stage heart failure is rising. Currently available Total Artificial Heart (TAH) systems consist of pump units with only limited durability, percutaneous tubes and bulky external equipment that limit the quality of life. Therefore we are focusing on the development of a fully implantable, highly durable destination therapy total artificial heart. The ReinHeart-TAH system consists of a passively filling pump unit driven by a low-wear linear drive between two artificial ventricles, an implantable control unit and a compliance chamber. The TAH is powered by a transcutaneous energy transmission system. The flow distribution inside the ventricles was analysed by fluid structure interaction simulation and particle image velocimetry measurements. Along with durability tests, the hydrodynamic performance and flow balance capability were evaluated in a mock circulation loop. Animal trials are ongoing. Based on fluid structure interaction simulation and particle image velocimetry, blood stagnation areas have been significantly reduced. In the mock circulation loop the ReinHeart-TAH generated a cardiac output of 5 l/min at an operating frequency of 120 bpm and an aortic pressure of 120/80 mmHg. The highly effective preload sensitivity of the passively filling ventricles allowed the sensorless integration of the Frank Starling mechanism. The ReinHeart-TAH effectively replaced the native heart's function in animals for up to 2 days. In vitro and in vivo testing showed a safe and effective function of the ReinHeart-TAH system. This has the potential to become an alternative to transplantation. However, before a first-in-man implant, chronic animal trials still have to be completed. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  1. Wireless microsensor network solutions for neurological implantable devices

    Science.gov (United States)

    Abraham, Jose K.; Whitchurch, Ashwin; Varadan, Vijay K.

    2005-05-01

    The design and development of wireless mocrosensor network systems for the treatment of many degenerative as well as traumatic neurological disorders is presented in this paper. Due to the advances in micro and nano sensors and wireless systems, the biomedical sensors have the potential to revolutionize many areas in healthcare systems. The integration of nanodevices with neurons that are in communication with smart microsensor systems has great potential in the treatment of many neurodegenerative brain disorders. It is well established that patients suffering from either Parkinson"s disease (PD) or Epilepsy have benefited from the advantages of implantable devices in the neural pathways of the brain to alter the undesired signals thus restoring proper function. In addition, implantable devices have successfully blocked pain signals and controlled various pelvic muscles in patients with urinary and fecal incontinence. Even though the existing technology has made a tremendous impact on controlling the deleterious effects of disease, it is still in its infancy. This paper presents solutions of many problems of today's implantable and neural-electronic interface devices by combining nanowires and microelectronics with BioMEMS and applying them at cellular level for the development of a total wireless feedback control system. The only device that will actually be implanted in this research is the electrodes. All necessary controllers will be housed in accessories that are outside the body that communicate with the implanted electrodes through tiny inductively-coupled antennas. A Parkinson disease patient can just wear a hat-system close to the implantable neural probe so that the patient is free to move around, while the sensors continually monitor, record, transmit all vital information to health care specialist. In the event of a problem, the system provides an early warning to the patient while they are still mobile thus providing them the opportunity to react and

  2. Fatigue induced changes in conical implant-abutment connections.

    Science.gov (United States)

    Blum, Kai; Wiest, Wolfram; Fella, Christian; Balles, Andreas; Dittmann, Jonas; Rack, Alexander; Maier, Dominik; Thomann, Ralf; Spies, Benedikt Christopher; Kohal, Ralf Joachim; Zabler, Simon; Nelson, Katja

    2015-11-01

    Based on the current lack of data and understanding of the wear behavior of dental two-piece implants, this study aims for evaluating the microgap formation and wear pattern of different implants in the course of cyclic loading. Several implant systems with different conical implant-abutment interfaces were purchased. The implants were first evaluated using synchrotron X-ray high-resolution radiography (SRX) and scanning electron microscopy (SEM). The implant-abutment assemblies were then subjected to cyclic loading at 98N and their microgap was evaluated after 100,000, 200,000 and 1 million cycles using SRX, synchrotron micro-tomography (μCT). Wear mechanisms of the implant-abutment connection (IAC) after 200,000 cycles and 1 million cycles were further characterized using SEM. All implants exhibit a microgap between the implant and abutment prior to loading. The gap size increased with cyclic loading with its changes being significantly higher within the first 200,000 cycles. Wear was seen in all implants regardless of their interface design. The wear pattern comprised adhesive wear and fretting. Wear behavior changed when a different mounting medium was used (brass vs. polymer). A micromotion of the abutment during cyclic loading can induce wear and wear particles in conical dental implant systems. This feature accompanied with the formation of a microgap at the IAC is highly relevant for the longevity of the implants. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  3. Wear at the Implant-Abutment Interface of Zirconia Abutments Manufactured by Three CAD/CAM Systems.

    Science.gov (United States)

    Pinheiro Tannure, Ana Luiza; Cunha, Alfredo Gonçalves; Borges Junior, Luiz Antônio; da Silva Concílio, Laís Regiane; Claro Neves, Ana Christina

    To evaluate the changes in the external-hexagon surface of the titanium (Ti) implant before and after mechanical cycling, when coupled with zirconia (Zr) abutments (A) manufactured by three computer-aided design/computer-aided manufacturing (CAD/CAM) systems (Neodent Digital, Zirkonzahn, and AmannGirrbach) and the ZrTi abutment manufactured by Neodent. Four groups were formed (n = 6): titanium implant with Zr AmannGirrbach abutment (AZrAG), with Zr Zirkonzahn abutment (AZrZ), with Zr Neodent abutment (AZrN), and with Zr abutment with infrastructure in Ti Neodent (AZrTiN). Standardized abutments were made from three identical abutments milled in wax. Images of the surface of each side of the hexagons of the implant were obtained by scanning electron microscopy, before and after mechanical cycling, to evaluate the parameters: (1) scratches in the hexagon face; (2) hexagon superior shoulder kneading; (3) hexagon shoulder wear; (4) alterations on the hexagon base; and (5) scratches on the hexagon top. The abutments were coupled with the implants, and Cr-Co crowns were cemented. The implant/abutment/crown assemblies were submitted to mechanical cycling (400 N, 8.0 Hz) for 1 million cycles. The observed changes were classified as follows: absence (0), mild (1), moderate (2), and severe (3). The results were analyzed using the Mann-Whitney, Kruskal-Wallis, and Dunn tests (P abutments, the AZrN group had shown more surface alterations. Among the Zr groups, AZrZ samples had shown the most altered surfaces, suggesting that alterations on the implant/Zr abutment hexagon surfaces are related to the abutment milled hexagon shape.

  4. Columnar transmitter based wireless power delivery system for implantable device in freely moving animals.

    Science.gov (United States)

    Eom, Kyungsik; Jeong, Joonsoo; Lee, Tae Hyung; Lee, Sung Eun; Jun, Sang Bum; Kim, Sung June

    2013-01-01

    A wireless power delivery system is developed to deliver electrical power to the neuroprosthetic devices that are implanted into animals freely moving inside the cage. The wireless powering cage is designed for long-term animal experiments without cumbersome wires for power supply or the replacement of batteries. In the present study, we propose a novel wireless power transmission system using resonator-based inductive links to increase power efficiency and to minimize the efficiency variations. A columnar transmitter coil is proposed to provide lateral uniformity of power efficiency. Using this columnar transmitter coil, only 7.2% efficiency fluctuation occurs from the maximum transmission efficiency of 25.9%. A flexible polymer-based planar type receiver coil is fabricated and assembled with a neural stimulator and an electrode. Using the designed columnar transmitter coil, the implantable device successfully operates while it moves freely inside the cage.

  5. A Wireless Magnetic Resonance Energy Transfer System for Micro Implantable Medical Sensors

    Directory of Open Access Journals (Sweden)

    Tianyang Yang

    2012-07-01

    Full Text Available Based on the magnetic resonance coupling principle, in this paper a wireless energy transfer system is designed and implemented for the power supply of micro-implantable medical sensors. The entire system is composed of the in vitro part, including the energy transmitting circuit and resonant transmitter coils, and in vivo part, including the micro resonant receiver coils and signal shaping chip which includes the rectifier module and LDO voltage regulator module. Transmitter and receiver coils are wound by Litz wire, and the diameter of the receiver coils is just 1.9 cm. The energy transfer efficiency of the four-coil system is greatly improved compared to the conventional two-coil system. When the distance between the transmitter coils and the receiver coils is 1.5 cm, the transfer efficiency is 85% at the frequency of 742 kHz. The power transfer efficiency can be optimized by adding magnetic enhanced resonators. The receiving voltage signal is converted to a stable output voltage of 3.3 V and a current of 10 mA at the distance of 2 cm. In addition, the output current varies with changes in the distance. The whole implanted part is packaged with PDMS of excellent biocompatibility and the volume of it is about 1 cm3.

  6. Evaluation of stabilization techniques for ion implant processing

    Science.gov (United States)

    Ross, Matthew F.; Wong, Selmer S.; Minter, Jason P.; Marlowe, Trey; Narcy, Mark E.; Livesay, William R.

    1999-06-01

    With the integration of high current ion implant processing into volume CMOS manufacturing, the need for photoresist stabilization to achieve a stable ion implant process is critical. This study compares electron beam stabilization, a non-thermal process, with more traditional thermal stabilization techniques such as hot plate baking and vacuum oven processing. The electron beam processing is carried out in a flood exposure system with no active heating of the wafer. These stabilization techniques are applied to typical ion implant processes that might be found in a CMOS production process flow. The stabilization processes are applied to a 1.1 micrometers thick PFI-38A i-line photoresist film prior to ion implant processing. Post stabilization CD variation is detailed with respect to wall slope and feature integrity. SEM photographs detail the effects of the stabilization technique on photoresist features. The thermal stability of the photoresist is shown for different levels of stabilization and post stabilization thermal cycling. Thermal flow stability of the photoresist is detailed via SEM photographs. A significant improvement in thermal stability is achieved with the electron beam process, such that photoresist features are stable to temperatures in excess of 200 degrees C. Ion implant processing parameters are evaluated and compared for the different stabilization methods. Ion implant system end-station chamber pressure is detailed as a function of ion implant process and stabilization condition. The ion implant process conditions are detailed for varying factors such as ion current, energy, and total dose. A reduction in the ion implant systems end-station chamber pressure is achieved with the electron beam stabilization process over the other techniques considered. This reduction in end-station chamber pressure is shown to provide a reduction in total process time for a given ion implant dose. Improvements in the ion implant process are detailed across

  7. Immediate and early function of Brånemark System implants placed in the esthetic zone: a 1-year prospective clinical multicenter study.

    Science.gov (United States)

    Maló, Paulo; Friberg, Bertil; Polizzi, Giovanni; Gualini, Federico; Vighagen, Torbjörn; Rangert, Bo

    2003-01-01

    Immediate/early implant function means great benefits for patients and therapists because treatment time and cost can be substantially reduced. This concept has become an accepted alternative for complete arch fixed restorations in the mandible, and clinical documentation is emerging for other indications. The purpose of this prospective clinical multicenter study was to evaluate the outcome of implants placed in incisor, canine, and premolar regions in maxillas or mandibles. Implants were loaded with provisional crowns and bridges on the same day or within a few days and were followed up for 1 year during function. Four centers treated 76 patients each in need of an implant-retained prosthesis in the anterior and premolar regions in the maxilla or mandible. A total of 116 titanium implants with machined surfaces (Brånemark System , Nobel Biocare AB, Gothenburg, Sweden) were placed: 74 in maxillas and 42 in mandibles. Eighty-seven prostheses were made, of which 63 were single crowns and 24 were bridges (supported by 53 splinted implants). Twenty-two implants in 14 patients were placed in fresh extraction sites. The goal with the preparation and insertion technique was to achieve good primary implant stability and a minimum implant insertion torque of 30 Ncm before the implant was completely seated. The occlusion was adjusted to eliminate direct contact with the provisional prostheses. After 6 months, the patients received their permanent prostheses. Sixty-seven patients were followed for 1 year. Five implants were lost in five patients, three in the maxilla and two in the mandible. Four of the lost implants were single-tooth replacements and one was splinted. The cumulative survival rate (CSR) was 95.7% for all implants after 1 year and 93.7% and 98.1% for single-tooth and splinted implants, respectively. There were no implant losses in the extraction sites. The CSR of 96% at 1 year indicates that immediate function of Brånemark System implants placed in incisor

  8. Evaluation of an infrared camera and X-ray system using implanted fiducials in patients with lung tumors for gated radiation therapy

    International Nuclear Information System (INIS)

    Willoughby, Twyla R.; Forbes, Alan R.; Buchholz, Daniel; Langen, Katja M.; Wagner, Thomas H.; Zeidan, Omar A.; Kupelian, Patrick A.; Meeks, Sanford L.

    2006-01-01

    Purpose: To report on the initial clinical use of a commercially available system to deliver gated treatment using implanted fiducials, in-room kV X-rays, and an infrared camera tracking system. Methods and Materials: ExacTrac Adaptive Gating from BrainLab is a localization system using infrared cameras and X-rays. Gating signals are the patient's breathing pattern obtained from infrared reflectors on the patient. kV X-rays of an implanted fiducial are synchronized to the breathing pattern. After localization and shift of the patient to isocenter, the breathing pattern is used to gate Radiation. Feasibility tests included localization accuracy, radiation output constancy, and dose distributions with gating. Clinical experience is reported on treatment of patients with small lung lesions. Results: Localization accuracy of a moving target with gating was 1.7 mm. Dose constancy measurements showed insignificant change in output with gating. Improvements of dose distributions on moving targets improved with gating. Eleven patients with lung lesions were implanted with 20 mm x 0.7 mm gold coil (Visicoil). The implanted fiducial was used to localize and treat the patients with gating. Treatment planning and repeat computed tomographic scans showed that the change in center of gross target volume (GTV) to implanted marker averaged 2.47 mm due in part to asymmetric tumor shrinkage. Conclusion: ExacTrac Adaptive Gating has been used to treat lung lesions. Initial system evaluation verified its accuracy and usability. Implanted fiducials are visible in X-rays and did not migrate

  9. Elders with implant overdentures: a 22-year clinical report.

    Science.gov (United States)

    Alsabeeha, Nabeel H M

    2012-09-01

    To report on the long-term survival and prosthodontic maintenance of two edentulous adults with mandibular overdentures supported by hydroxyapatite (HA)-coated implants. Mandibular implant overdentures are a successful treatment option with positive impact on the quality of life of elderly edentulous adults. Long-term survival of the implants requires continued rigorous prosthodontic maintenance. Two elderly edentulous adults with mandibular overdentures supported by 2 HA-coated implants were presented for prosthodontic rehabilitation after 22 years of placement. The implants were osseo-integrated and surviving at presentation based on accepted criteria. The mandibular implant overdentures suffered recurrent loss of retention and stability. Prosthodontic treatment involving the replacement of defective attachment systems and construction of new sets of mandibular implant overdentures opposing complete maxillary dentures is presented. The long-term survival of mandibular 2-implant overdentures requires continued prosthodontic maintenance. A conservative approach in the rehabilitation of two older edentulous adults with mandibular 2-implant overdentures was described including proper selection of attachment systems. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  10. Cochlear implantation in children and adults in Switzerland.

    Science.gov (United States)

    Brand, Yves; Senn, Pascal; Kompis, Martin; Dillier, Norbert; Allum, John H J

    2014-02-04

    The cochlear implant (CI) is one of the most successful neural prostheses developed to date. It offers artificial hearing to individuals with profound sensorineural hearing loss and with insufficient benefit from conventional hearing aids. The first implants available some 30 years ago provided a limited sensation of sound. The benefit for users of these early systems was mostly a facilitation of lip-reading based communication rather than an understanding of speech. Considerable progress has been made since then. Modern, multichannel implant systems feature complex speech processing strategies, high stimulation rates and multiple sites of stimulation in the cochlea. Equipped with such a state-of-the-art system, the majority of recipients today can communicate orally without visual cues and can even use the telephone. The impact of CIs on deaf individuals and on the deaf community has thus been exceptional. To date, more than 300,000 patients worldwide have received CIs. In Switzerland, the first implantation was performed in 1977 and, as of 2012, over 2,000 systems have been implanted with a current rate of around 150 CIs per year. The primary purpose of this article is to provide a contemporary overview of cochlear implantation, emphasising the situation in Switzerland.

  11. Finite element analysis of the stress distributions in peri-implant bone in modified and standard-threaded dental implants

    Directory of Open Access Journals (Sweden)

    Serkan Dundar

    2016-01-01

    Full Text Available The aim of this study was to examine the stress distributions with three different loads in two different geometric and threaded types of dental implants by finite element analysis. For this purpose, two different implant models, Nobel Replace and Nobel Active (Nobel Biocare, Zurich, Switzerland, which are currently used in clinical cases, were constructed by using ANSYS Workbench 12.1. The stress distributions on components of the implant system under three different static loadings were analysed for the two models. The maximum stress values that occurred in all components were observed in FIII (300 N. The maximum stress values occurred in FIII (300 N when the Nobel Replace implant is used, whereas the lowest ones, in the case of FI (150 N loading in the Nobel Active implant. In all models, the maximum tensions were observed to be in the neck region of the implants. Increasing the connection between the implant and the bone surface may allow more uniform distribution of the forces of the dental implant and may protect the bone around the implant. Thus, the implant could remain in the mouth for longer periods. Variable-thread tapered implants can increase the implant and bone contact.

  12. Predicting the Failure of Dental Implants Using Supervised Learning Techniques

    Directory of Open Access Journals (Sweden)

    Chia-Hui Liu

    2018-05-01

    Full Text Available Prosthodontic treatment has been a crucial part of dental treatment for patients with full mouth rehabilitation. Dental implant surgeries that replace conventional dentures using titanium fixtures have become the top choice. However, because of the wide-ranging scope of implant surgeries, patients’ body conditions, surgeons’ experience, and the choice of implant system should be considered during treatment. The higher price charged by dental implant treatments compared to conventional dentures has led to a rush among medical staff; therefore, the future impact of surgeries has not been analyzed in detail, resulting in medial disputes. Previous literature on the success factors of dental implants is mainly focused on single factors such as patients’ systemic diseases, operation methods, or prosthesis types for statistical correlation significance analysis. This study developed a prediction model for providing an early warning mechanism to reduce the chances of dental implant failure. We collected the clinical data of patients who received artificial dental implants at the case hospital for a total of 8 categories and 20 variables. Supervised learning techniques such as decision tree (DT, support vector machines, logistic regressions, and classifier ensembles (i.e., Bagging and AdaBoost were used to analyze the prediction of the failure of dental implants. The results show that DT with both Bagging and Adaboost techniques possesses the highest prediction performance for the failure of dental implant (area under the receiver operating characteristic curve, AUC: 0.741; the analysis also revealed that the implant systems affect dental implant failure. The model can help clinical surgeons to reduce medical failures by choosing the optimal implant system and prosthodontics treatments for their patients.

  13. MRI information for commonly used otologic implants: review and update.

    Science.gov (United States)

    Azadarmaki, Roya; Tubbs, Rhonda; Chen, Douglas A; Shellock, Frank G

    2014-04-01

    To review information on magnetic resonance imaging (MRI) issues for commonly used otologic implants. Manufacturing companies, National Library of Medicine's online database, and an additional online database (www.MRIsafety.com). A literature review of the National Library of Medicine's online database with focus on MRI issues for otologic implants was performed. The MRI information on implants provided by manufacturers was reviewed. Baha and Ponto Pro osseointegrated implants' abutment and fixture and the implanted magnet of the Sophono Alpha 1 and 2 abutment-free systems are approved for 3-Tesla magnetic resonance (MR) systems. The external processors of these devices are MR Unsafe. Of the implants tested, middle ear ossicular prostheses, including stapes prostheses, except for the 1987 McGee prosthesis, are MR Conditional for 1.5-Tesla (and many are approved for 3-Tesla) MR systems. Cochlear implants with removable magnets are approved for patients undergoing MRI at 1.5 Tesla after magnet removal. The MED-EL PULSAR, SONATA, CONCERT, and CONCERT PIN cochlear implants can be used in patients undergoing MRI at 1.5 Tesla with application of a protective bandage. The MED-EL COMBI 40+ can be used in 0.2-Tesla MR systems. Implants made from nonmagnetic and nonconducting materials are MR Safe. Knowledge of MRI guidelines for commonly used otologic implants is important. Guidelines on MRI issues approved by the US Food and Drug Administration are not always the same compared with other parts of the world. This monograph provides a current reference for physicians on MRI issues for commonly used otologic implants.

  14. Air Abrasive Disinfection of Implant Surfaces in a Simulated Model of Peri-Implantitis

    Science.gov (United States)

    2016-06-01

    may be higher in patients diagnosed with periodontal disease, systemic chronic disease such as diabetes or patients who smoke tobacco.9,10 One of...flora associated with peri-implantitis is similar to that found in chronic periodontitis .14 Gram-positive, facultative bacteria are normally...9):1490-5. 20. Heitz-Mayfield LJ, Lang NP. Comparative biology of chronic and aggressive periodontitis vs. peri-implantitis. Periodontol 2000

  15. Implantable enzyme amperometric biosensors.

    Science.gov (United States)

    Kotanen, Christian N; Moussy, Francis Gabriel; Carrara, Sandro; Guiseppi-Elie, Anthony

    2012-05-15

    The implantable enzyme amperometric biosensor continues as the dominant in vivo format for the detection, monitoring and reporting of biochemical analytes related to a wide range of pathologies. Widely used in animal studies, there is increasing emphasis on their use in diabetes care and management, the management of trauma-associated hemorrhage and in critical care monitoring by intensivists in the ICU. These frontier opportunities demand continuous indwelling performance for up to several years, well in excess of the currently approved seven days. This review outlines the many challenges to successful deployment of chronically implantable amperometric enzyme biosensors and emphasizes the emerging technological approaches in their continued development. The foreign body response plays a prominent role in implantable biotransducer failure. Topics considering the approaches to mitigate the inflammatory response, use of biomimetic chemistries, nanostructured topographies, drug eluting constructs, and tissue-to-device interface modulus matching are reviewed. Similarly, factors that influence biotransducer performance such as enzyme stability, substrate interference, mediator selection and calibration are reviewed. For the biosensor system, the opportunities and challenges of integration, guided by footprint requirements, the limitations of mixed signal electronics, and power requirements, has produced three systems approaches. The potential is great. However, integration along the multiple length scales needed to address fundamental issues and integration across the diverse disciplines needed to achieve success of these highly integrated systems, continues to be a challenge in the development and deployment of implantable amperometric enzyme biosensor systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Technical feasibility of the implantation of a monorail stent system into the renal arteries without pre-dilatation

    International Nuclear Information System (INIS)

    Neumann, C.; Dorffner, R.; Gschwendtner, M.; Karnel, F.; Mair, J.; Dorffner, G.

    2005-01-01

    Purpose: to evaluate the technical feasibility of the implantation of the monorail RX Herculink trademark system into the renal arteries without pre-dilatation. Materials and methods: forty-two patients (mean age 71 years) from four centers with a total of 44 renal artery stenoses underwent implantation of the RX Herculink trademark stent. The mean grade of the stenosis was 83.8%, the mean length 7.5 mm. The stenoses were ostial in 38 cases and in immediate proximity to the ostium in 6 cases. The mean follow-up-period was 57 weeks (24 - 176 weeks). Results: in 42 cases, the implantation was successful without pre-dilatation. In 2 cases, pre-dilatation was carried out. In none of the cases, detachment of the stent from the balloon was observed. In one stenosis with a length of 17 mm, implantation of two stents was performed. In 9 cases, post-dilatation with a larger balloon or higher balloon pressure was necessary. Residual stenoses exceeding 30% were not observed. Two patients developed local bleeding at the puncture site. During the follow-up, restenoses were observed in 5 stents after 26 to 126 weeks, which necessitated a second intervention in 3 cases (PTA in 2 cases, re-stenting in 1 case). The primary patency rate after 6 and 12 months was 0.92 ± 0.056 according to Kaplan-Meier, the secondary patency rate after 6 and 12 months was 1.0 ± 0.0. Conclusion: implantation of the RX Herculink trademark stent system into the renal arteries without pre-dilatation is technically feasible and safe. Even without pre-dilatation, the stent-system can be advanced through the stenosis without detachment. The complication rate is low. Our clinical results are comparable to previous studies. (orig.)

  17. Implantation activation annealing of Si-implanted gallium nitride at temperatures > 1,100 C

    International Nuclear Information System (INIS)

    Zolper, J.C.; Han, J.; Biefeld, R.M.

    1997-01-01

    The activation annealing of Si-implanted GaN is reported for temperatures from 1,100 to 1,400 C. Although previous work has shown that Si-implanted GaN can be activated by a rapid thermal annealing at ∼1,100 C, it was also shown that significant damage remained in the crystal. Therefore, both AlN-encapsulated and uncapped Si-implanted GaN samples were annealed in a metal organic chemical vapor deposition system in a N 2 /NH 3 ambient to further assess the annealing process. Electrical Hall characterization shows increases in carrier density and mobility for annealing up to 1,300 C before degrading at 1,400 C due to decomposition of the GaN epilayer. Rutherford backscattering spectra show that the high annealing temperatures reduce the implantation induced damage profile but do not completely restore the as-grown crystallinity

  18. [Total cervical disk replacement--implant-specific approaches: keel implant (Prodisc-C intervertebral disk prosthesis)].

    Science.gov (United States)

    Korge, Andreas; Siepe, Christoph J; Heider, Franziska; Mayer, H Michael

    2010-11-01

    Dynamic intervertebral support of the cervical spine via an anterolateral approach using a modular artificial disk prosthesis with end-plate fixation by central keel fixation. Cervical median or mediolateral disk herniations, symptomatic cervical disk disease (SCDD) with anterior osseous, ligamentous and/or discogenic narrowing of the spinal canal. Cervical fractures, tumors, osteoporosis, arthrogenic neck pain, severe facet degeneration, increased segmental instability, ossification of posterior longitudinal ligament (OPLL), severe osteopenia, acute and chronic systemic, spinal or local infections, systemic and metabolic diseases, known implant allergy, pregnancy, severe adiposity (body mass index > 36 kg/m2), reduced patient compliance, alcohol abuse, drug abuse and dependency. Exposure of the anterior cervical spine using the minimally invasive anterolateral approach. Intervertebral fixation of retainer screws. Intervertebral diskectomy. Segmental distraction with vertebral body retainer and vertebral distractor. Removal of end-plate cartilage. Microscopically assisted decompression of spinal canal. Insertion of trial implant to determine appropriate implant size, height and position. After biplanar image intensifier control, drilling for keel preparation using drill guide and drill bit, keel-cut cleaner to remove bone material from the keel cut, radiologic control of depth of the keel cut using the corresponding position gauge. Implantation of original implant under lateral image intensifier control. Removal of implant inserter. Functional postoperative care and mobilization without external support, brace not used routinely, soft brace possible for 14 days due to postoperative pain syndromes. Implantation of 100 cervical Prodisc-C disk prostheses in 78 patients (average age 48 years) at a single center. Clinical and radiologic follow-up 24 months postoperatively. Significant improvement based on visual analog scale and Neck Disability Index. Radiologic

  19. PAIN RELIEF MEDIATED BY IMPLANTABLE DRUG-DELIVERY DEVICES

    NARCIS (Netherlands)

    HOEKSTRA, A

    Various totally implantable drug delivery systems from single access ports to micropumps are now available for administration of repeated boluses, and continuous or programmable infusions. In this respect, emphasis is given to a relatively cheap, totally implantable system for self-administering

  20. Chewing efficiency and maximum bite force with different attachment systems of implant overdentures: a crossover study.

    Science.gov (United States)

    Elsyad, Moustafa Abdou; Khairallah, Ahmed Samir

    2017-06-01

    This crossover study aimed to evaluate and compare chewing efficiency and maximum bite force (MBF) with resilient telescopic and bar attachment systems of implant overdentures in patients with atrophied mandibles. Ten participants with severely resorbed mandibles and persistent denture problems received new maxillary and mandibular conventional dentures (control, CD). After 3 months of adaptation, two implants were inserted in canine region of the mandible. In a quasi-random method, overdentures were connected to the implants with either bar overdentures (BOD) or resilient telescopic overdentures (TOD) attachment systems. Chewing efficiency in terms of unmixed fraction (UF) was measured using chewing gum (after 5, 10, 20, 30 and 50 strokes), and MBF was measured using a bite force transducer. Measurements were performed 3 months after using each of the following prostheses: CD, BOD and TOD. Chewing efficiency and MBF increased significantly with BOD and TOD compared to CD. As the number of chewing cycles increased, the UF decreased. TOD recorded significant higher chewing efficiency and MBF than BOD. Resilient telescopic attachments are associated with increased chewing efficiency and MBF compared bar attachments when used to retain overdentures to the implants in patients with atrophied mandibles. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. 《采薇》的叙事伦理分析%Narrative Ethics of Cai Wei

    Institute of Scientific and Technical Information of China (English)

    王海燕

    2014-01-01

    The controversial dilemma of how to understand Boyi, Shuqi in Luxun’ s novel Cai Wei, it is not a realistic ethical problem, which should be based on the novel's narrative ethics to answer. Narrative ethics refers to various forms of arrangement of ethical dimension revealed. Novel manifests sympathy ethics to Boyi, Shu Qi through the narrative angle choice and narrative distance controlling. Also, by the counterpoint to character, event and ironic expression in structure, novel conveys the ethics excluding to all sorts of characters from emperor Zhouwu to A Jin. Compared to other “Generational change” theme novels of Luxun, the complication of narrative ethics of Cai Wei not only is the projection of reality, but also reflects the further conscious to narrative art of Luxun.%《采薇》中颇有争议的“如何理解伯夷、叔齐”这一难点,并不是一个现实伦理问题,而应依据小说的叙事伦理来解答。叙事伦理即各种形式安排透露出的伦理维度。小说通过叙事角度的选择与叙事距离的控制体现出对伯夷、叔齐的伦理同情,而由结构上的人物对位与事件对位及反讽表达的是对自周武王至阿金诸色人物的伦理拒斥。与前期同是“易代”主题的小说相比,《采薇》叙事伦理的复杂化既是现实的投射,也体现了鲁迅对于小说叙事艺术的进一步自觉。

  2. The impact of glucocorticosteroids administered for systemic diseases on the osseointegration and survival of dental implants placed without bone grafting-A retrospective study in 31 patients.

    Science.gov (United States)

    Petsinis, Vassilis; Kamperos, Georgios; Alexandridi, Foteini; Alexandridis, Konstantinos

    2017-08-01

    To evaluate the impact of glucocorticosteroids, administered for the treatment of systemic diseases, on the osseointegration and survival of dental implants placed without bone grafting. A retrospective study was conducted in search of patients treated with dental implants while receiving glucocorticosteroid therapy for various systemic diseases. In these cases, a conventional two-stage surgical protocol was used, without bone regeneration procedures. The osseointegration was clinically and radiographically tested at the uncovering of the implants. The follow-up after loading was set at a minimum of 3 years. A total of 31 patients were included in the study. Of the 105 dental implants placed, 104 were osseointegrated (99%). No bone absorption was radiographically noted at the uncovering of the osseointegrated implants. All of the osseointegrated implants were successfully loaded for the prosthetic restoration. The mean follow-up period after loading was 71 months, with an implant survival rate of 99%. Glucocorticosteroid intake for systemic diseases does not have a significant impact on the osseointegration and the 3-year survival of dental implants placed with a conventional two-stage surgical protocol and without bone grafting. Therefore, it should not be considered a contraindication for dental implant placement. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Dynamic Stability of Maglev Systems,

    Science.gov (United States)

    1992-04-01

    AD-A259 178 ANL-92/21 Materials and Components Dynamic Stability of Technology Division Materials and Components Maglev Systems Technology Division...of Maglev Systems Y. Cai, S. S. Chen, and T. M. Mulcahy Materials and Components Technology Division D. M. Rote Center for Transportation Research...of Maglev System with L-Shaped Guideway ......................................... 6 3 Stability of M aglev System s

  4. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  5. Digital photoelastic analysis applied to implant dentistry

    Science.gov (United States)

    Ramesh, K.; Hariprasad, M. P.; Bhuvanewari, S.

    2016-12-01

    Development of improved designs of implant systems in dentistry have necessitated the study of stress fields in the implant regions of the mandible/maxilla for better understanding of the biomechanics involved. Photoelasticity has been used for various studies related to dental implants in view of whole field visualization of maximum shear stress in the form of isochromatic contours. The potential of digital photoelasticity has not been fully exploited in the field of implant dentistry. In this paper, the fringe field in the vicinity of the connected implants (All-On-Four® concept) is analyzed using recent advances in digital photoelasticity. Initially, a novel 3-D photoelastic model making procedure, to closely mimic all the anatomical features of the human mandible is proposed. By choosing appropriate orientation of the model with respect to the light path, the essential region of interest were sought to be analysed while keeping the model under live loading conditions. Need for a sophisticated software module to carefully identify the model domain has been brought out. For data extraction, five-step method is used and isochromatics are evaluated by twelve fringe photoelasticity. In addition to the isochromatic fringe field, whole field isoclinic data is also obtained for the first time in implant dentistry, which could throw important information in improving the structural stability of the implant systems. Analysis is carried out for the implant in the molar as well as the incisor region. In addition, the interaction effects of loaded molar implant on the incisor area are also studied.

  6. A direct plasma injection system into an RFQ for clean and safe ion implantation

    International Nuclear Information System (INIS)

    Takeuchi, T.; Katayama, T.; Okamura, M.; Yano, K.; Sakumi, A.; Hattori, T.; Hayashizaki, N.; Jameson, R.A.

    2002-01-01

    A new injection system, direct plasma injection system, was tested and its principle was proved successfully. We found that one of advantages of this injection system was efficient consumption of source materials. Large portions of induced ions can be injected into a first stage accelerator. This feature is quite useful for ion implantation applications, because toxic exhaust gas can be eliminated. In order to utilize this system for industrial application, the feasibility of a boron injection scheme using a Nd:YAG laser system was investigated

  7. Magnet-Retained Two-Mini-Implant Overdenture: Clinical and Mechanical Consideration

    Directory of Open Access Journals (Sweden)

    Yuichi Ishida

    2016-10-01

    Full Text Available Two-implant overdentures have become the accepted treatment for restoring mandibular edentulism. The dimensions of regular implants sometimes limit their use, such as in the case of narrow ridges. Mini-implants with reduced diameters (less than 3.0 mm enable insertion into narrow ridges. A magnet-retained two-mini-implant overdenture system was developed and is described in this paper. Additionally, we describe a clinical mandibular procedure using the system and evaluate its biomechanical performance.

  8. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  9. Wireless Power Transfer Strategies for Implantable Bioelectronics.

    Science.gov (United States)

    Agarwal, Kush; Jegadeesan, Rangarajan; Guo, Yong-Xin; Thakor, Nitish V

    2017-01-01

    Neural implants have emerged over the last decade as highly effective solutions for the treatment of dysfunctions and disorders of the nervous system. These implants establish a direct, often bidirectional, interface to the nervous system, both sensing neural signals and providing therapeutic treatments. As a result of the technological progress and successful clinical demonstrations, completely implantable solutions have become a reality and are now commercially available for the treatment of various functional disorders. Central to this development is the wireless power transfer (WPT) that has enabled implantable medical devices (IMDs) to function for extended durations in mobile subjects. In this review, we present the theory, link design, and challenges, along with their probable solutions for the traditional near-field resonant inductively coupled WPT, capacitively coupled short-ranged WPT, and more recently developed ultrasonic, mid-field, and far-field coupled WPT technologies for implantable applications. A comparison of various power transfer methods based on their power budgets and WPT range follows. Power requirements of specific implants like cochlear, retinal, cortical, and peripheral are also considered and currently available IMD solutions are discussed. Patient's safety concerns with respect to electrical, biological, physical, electromagnetic interference, and cyber security from an implanted neurotech device are also explored in this review. Finally, we discuss and anticipate future developments that will enhance the capabilities of current-day wirelessly powered implants and make them more efficient and integrable with other electronic components in IMDs.

  10. A wireless transmission system powered by an enzyme biofuel cell implanted in an orange.

    Science.gov (United States)

    MacVittie, Kevin; Conlon, Tyler; Katz, Evgeny

    2015-12-01

    A biofuel cell composed of catalytic electrodes made of "buckypaper" modified with PQQ-dependent glucose dehydrogenase and FAD-dependent fructose dehydrogenase on the anode and with laccase on the cathode was used to activate a wireless information transmission system. The cathode/anode pair was implanted in orange pulp extracting power from its content (glucose and fructose in the juice). The open circuit voltage, Voc, short circuit current density, jsc, and maximum power produced by the biofuel cell, Pmax, were found as ca. 0.6 V, ca. 0.33 mA·cm(-2) and 670 μW, respectively. The voltage produced by the biofuel cell was amplified with an energy harvesting circuit and applied to a wireless transmitter. The present study continues the research line where different implantable biofuel cells are used for the activation of electronic devices. The study emphasizes the biosensor and environmental monitoring applications of implantable biofuel cells harvesting power from natural sources, rather than their biomedical use. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Evidence for multiple sources of 10Be in the early solar system

    DEFF Research Database (Denmark)

    Wielandt, Daniel Kim Peel; Nagashima, Kazuhide; Krot, Alexander N.

    2012-01-01

    Beryllium-10 is a short-lived radionuclide (t 1/2 = 1.4 Myr) uniquely synthesized by spallation reactions and inferred to have been present when the solar system's oldest solids (calcium-aluminum-rich inclusions, CAIs) formed. Yet, the astrophysical site of 10Be nucleosynthesis is uncertain. We...... in the gaseous CAI-forming reservoir, or in the inclusions themselves: this indicates at least two nucleosynthetic sources of 10Be in the early solar system. The most promising locale for 10Be synthesis is close to the proto-Sun during its early mass-accreting stages, as these are thought to coincide...

  12. Low-Gain, Low-Noise Integrated Neuronal Amplifier for Implantable Artifact-Reduction Recording System

    OpenAIRE

    Zbrzeski, Adeline; Lewis, Noëlle; Rummens, Francois; Jung, Ranu; N'Kaoua, Gilles; Benazzouz, Abdelhamid; Renaud, Sylvie

    2013-01-01

    Brain neuroprostheses for neuromodulation are being designed to monitor the neural activity of the brain in the vicinity of the region being stimulated using a single macro-electrode. Using a single macro-electrode, recent neuromodulation studies show that recording systems with a low gain neuronal amplifier and successive amplifier stages can reduce or reject stimulation artifacts. These systems were made with off-the-shelf components that are not amendable for future implant design. A low-g...

  13. SIMPLANT: analytic calculation of ion implantation within the Tadpance system

    International Nuclear Information System (INIS)

    Fawcett, R.J.

    1988-04-01

    An analytic method for calculating the concentration distribution of dopant atoms introduced into a multilayer semiconductor device by ion beam implantation is explained. Computer software written to apply the method is described. The operation of the software within a semiconductor process and device modelling package is outlined. Implantation distributions generated by the software are illustrated. (author)

  14. Ion implantation for semiconductors

    International Nuclear Information System (INIS)

    Grey-Morgan, T.

    1995-01-01

    Full text: Over the past two decades, thousands of particle accelerators have been used to implant foreign atoms like boron, phosphorus and arsenic into silicon crystal wafers to produce special embedded layers for manufacturing semiconductor devices. Depending on the device required, the atomic species, the depth of implant and doping levels are the main parameters for the implantation process; the selection and parameter control is totally automated. The depth of the implant, usually less than 1 micron, is determined by the ion energy, which can be varied between 2 and 600 keV. The ion beam is extracted from a Freeman or Bernas type ion source and accelerated to 60 keV before mass analysis. For higher beam energies postacceleration is applied up to 200 keV and even higher energies can be achieved by mass selecting multiplycharged ions, but with a corresponding reduction in beam output. Depending on the device to be manufactured, doping levels can range from 10 10 to 10 15 atoms/cm 2 and are controlled by implanter beam currents in the range up to 30mA; continuous process monitoring ensures uniformity across the wafer of better than 1 % . As semiconductor devices get smaller, additional sophistication is required in the design of the implanter. The silicon wafers charge electrically during implantation and this charge must be dissipated continuously to reduce the electrical stress in the device and avoid destructive electrical breakdown. Electron flood guns produce low energy electrons (below 10 electronvolts) to neutralize positive charge buildup and implanter design must ensure minimum contamination by other isotopic species and ensure low internal sputter rates. The pace of technology in the semiconductor industry is such that implanters are being built now for 256 Megabit circuits but which are only likely to be widely available five years from now. Several specialist companies manufacture implanter systems, each costing around US$5 million, depending on the

  15. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search...... of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  16. A temperature sensor implant for active implantable medical devices for in vivo subacute heating tests under MRI.

    Science.gov (United States)

    Silemek, Berk; Acikel, Volkan; Oto, Cagdas; Alipour, Akbar; Aykut, Zaliha Gamze; Algin, Oktay; Atalar, Ergin

    2018-05-01

    To introduce a temperature sensor implant (TSI) that mimics an active implantable medical device (AIMD) for animal testing of MRI heating. Computer simulations and phantom experiments poorly represent potential temperature increases. Animal experiments could be a better model, but heating experiments conducted immediately after the surgery suffer from alterations of the thermoregulatory and tissue properties during acute testing conditions. Therefore, the aim of this study was to introduce a temperature sensor implant that mimics an AIMD and capable of measuring the electrode temperature after implantation of the device without any further intervention at any time after the surgery in an animal model. A battery-operated TSI, which resembled an AIMD, was used to measure the lead temperature and impedance and the case temperature. The measured values were transmitted to an external computer via a low-power Bluetooth communication protocol. In addition to validation experiments on the phantom, a sheep experiment was conducted to test the feasibility of the system in subacute conditions. The measurements had a maximum of 0.5°C difference compared to fiber-optic temperature probes. In vivo animal experiments demonstrated feasibility of the system. An active implant, which can measure its own temperature, was proposed to investigate implant heating during MRI examinations. Magn Reson Med 79:2824-2832, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  17. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates.

    Science.gov (United States)

    Nickenig, Hans-Joachim; Eitner, Stephan

    2007-01-01

    We assessed the reliability of implant placement after virtual planning of implant positions using cone-beam CT data and surgical guide templates. A total of 102 patients (250 implants, 55.4% mandibular; mean patient age, 40.4 years) who had undergone implant treatment therapy in an armed forces dental clinic (Cologne, Germany) between July 1, 2005 and December 1, 2005. They were treated with a system that allows transfer of virtual planning to surgical guide templates. Only in eight cases the surgical guides were not used because a delayed implant placement was necessary. In four posterior mandibular cases, handling was limited because of reduced interocclusal distance, requiring 50% shortening of the drill guides. The predictability of implant size was high: only one implant was changed to a smaller diameter (because of insufficient bone). In all cases, critical anatomical structures were protected and no complications were detected in postoperative panoramic radiographs. In 58.1% (147) of the 250 implants, a flapless surgery plan was realized. Implant placement after virtual planning of implant positions using cone beam CT data and surgical templates can be reliable for preoperative assessment of implant size, position, and anatomical complications. It is also indicative of cases amenable to flapless surgery.

  18. Middle ear implants

    Directory of Open Access Journals (Sweden)

    K S Gangadhara Somayaji

    2013-01-01

    Full Text Available Hearing loss is becoming more common in the society living in cities with lot of background noise around, and frequent use of gadgets like mobile phones, MP3s, and IPods are adding to the problem. The loss may involve the conductive or perceptive pathway. Majority of the patients with conductive hearing loss will revert back to normal hearing levels with medical and/or surgical treatment. However, in sensorineural hearing loss, many factors are involved in the management. Though traditionally hearing aids in various forms are the most commonly used modality in managing these patients, there are some drawbacks associated with them. Implantable middle ear amplifiers represent the most recent breakthrough in the management of hearing loss. Middle ear implants are surgically implanted electronic devices that aim to correct hearing loss by stimulating the ossicular chain or middle ear. Of late, they are also being used in the management of congenital conductive hearing loss and certain cases of chronic otitis media with residual hearing loss. The article aims to provide general information about the technology, indications and contraindications, selection of candidates, available systems, and advantages of middle ear implants. (MEI

  19. Pacemaker dependency after transcatheter aortic valve implantation with the self-expanding Medtronic CoreValve System.

    Science.gov (United States)

    van der Boon, Robert M A; Van Mieghem, Nicolas M; Theuns, Dominic A; Nuis, Rutger-Jan; Nauta, Sjoerd T; Serruys, Patrick W; Jordaens, Luc; van Domburg, Ron T; de Jaegere, Peter P T

    2013-09-30

    To determine pacemaker (PM) dependency at follow-up visit in patients who underwent new permanent pacemaker implantation (PPI) following transcatheter aortic valve implantation (TAVI). Single center prospective observational study including 167 patients without previous PM implantation who underwent TAVI with the self-expanding Medtronic CoreValve System (MCS) between November 2005 and February 2011. PM dependency was defined by the presence of a high degree atrioventricular block (HDAVB; second [AV2] and third degree [AV3B]), or a slow (atrial fibrilation with slow response (n=1, 2.8%) and left bundle branch block (n=1, 2.8%). Long term follow-up was complete for all patients and ranged from 1 to 40 months (median (IQR): 11.5 (5.0-18.0 months). Of those patients with a HDAVB, 16 out of the 30 patients (53.3%) were PM independent at follow-up visit (complete or partial resolution of the AV conduction abnormality). Overall, 20 out of the 36 patients (55.6%) who received a new PM following TAVI were PM independent at follow-up. Partial and even complete resolution of peri-operative AV conduction abnormalities after MCS valve implantation occurred in more than half of the patients. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  20. Experimental investigation of commercial small diameter dental implants in porcine mandibular segments.

    Science.gov (United States)

    Hasan, Istabrak; Heinemann, Friedhelm; Schwegmann, Monika; Keilig, Ludger; Stark, Helmut; Bourauel, Christoph

    2017-02-01

    Small diameter (mini) dental implants have become more popular in recent years as alternatives to classical implant treatment in clinical cases with critical bony situations. However, an in-depth scientific analysis of the mechanical and biomechanical effects of small diameter implants has not yet been published. The aim of the present study was to investigate experimentally different commercial mini implants by measuring their displacements under immediate loading. Twelve commercially available mini implants were measured. Implants were inserted into porcine mandibular segments and loaded by means of a predefined displacement of 0.5 mm of the loading system. The implants were loaded at an angle of 30° to the implant long axis using the self-developed biomechanical hexapod measurement system. Implant displacements were registered. The experimental results were compared to the numerical ones from a previous study. Measured implant displacements were within the range of 39-194 μm. A large variation in the displacements was obtained among the different implant systems due to the different designs and thread profiles. Comparing experimental and numerical results, the displacements that were obtained numerically were within the range of 79-347 μm. The different commercial mini implants showed acceptable primary stability and could be loaded immediately after their insertion.

  1. Comparison of two systems for rigidly connecting 2.0-mm bone screws to an implantable device : in vitro stability testing

    NARCIS (Netherlands)

    van Loon, JP; de Bont, LGM; Verkerke, GJ

    The stability of a screw-fixed implantable device can be improved by eliminating the freedom of movement between the screws and the device. Two systems have been developed for rigidly connecting 2.0-mm bone screws to an implantable device, and the aim of this study was to test and compare the

  2. Crystal structures of coordination polymers from CaI2 and proline

    Directory of Open Access Journals (Sweden)

    Kevin Lamberts

    2015-06-01

    Full Text Available Completing our reports concerning the reaction products from calcium halides and the amino acid proline, two different solids were found for the reaction of l- and dl-proline with CaI2. The enantiopure amino acid yields the one-dimensional coordination polymer catena-poly[[aqua-μ3-l-proline-tetra-μ2-l-proline-dicalcium] tetraiodide 1.7-hydrate], {[Ca2(C5H9NO25(H2O]I4·1.7H2O}n, (1, with two independent Ca2+ cations in characteristic seven- and eightfold coordination. Five symmetry-independent zwitterionic l-proline molecules bridge the metal sites into a cationic polymer. Racemic proline forms with Ca2+ cations heterochiral chains of the one-dimensional polymer catena-poly[[diaquadi-μ2-dl-proline-calcium] diiodide], {[Ca(C5H9NO22(H2O2]I2}n, (2. The centrosymmetric structure is built by one Ca2+ cation that is bridged towards its symmetry equivalents by two zwitterionic proline molecules. In both structures, the iodide ions remain non-coordinating and hydrogen bonds are formed between these counter-anions, the amino groups, coordinating and co-crystallized water molecules. While the overall composition of (1 and (2 is in line with other structures from calcium halides and amino acids, the diversity of the carboxylate coordination geometry is quite surprising.

  3. Health-economic evaluation in implant trials: design considerations.

    Science.gov (United States)

    Alt, Volker; Pavlidis, Theodoros; Szalay, Gabor; Heiss, Christian; Schnettler, Reinhard

    2009-01-01

    In today's world, demonstration of the safety, efficacy, and quality of a new treatment strategy is no longer sufficient in many countries for market entry and reimbursement in the public healthcare system. This implies that new implants in orthopedic and orthopedic trauma surgery not only must be shown to lead to better medical outcome compared with the standard of care implant, but also must be shown to exhibit "good value" for the money for the public health-care system based on sound economic data from health-economic studies. The purpose of this article is to elucidate a framework for health-economic aspects alongside implant trials, with the assumption that the new implant is more costly but potentially better than the control implant. Cost-effectiveness, cost-utility, and cost-benefit studies are suitable for the assessment of the health-economic value of a new implant. The following criteria should be considered for a health-economic study design in the context with an implant: i) it should state medical benefits of the new implant compared with the control implant; ii) it should precise the type of health economic study; iii) it should define the methodological approach, perspective of the study, and types of costs; iv) if necessary, it should state discount costs and/benefits; and v) a sound sensitivity analysis should be included. Furthermore, close cooperation between researchers, clinicians, and health economists is essential.

  4. Biomechanical rationale and evaluation of an implant system for rib fracture fixation

    OpenAIRE

    Bottlang, M.; Walleser, S.; Noll, M.; Honold, S.; Madey, S. M.; Fitzpatrick, D.; Long, W. B.

    2010-01-01

    Background Biomechanical research directed at developing customized implant solutions for rib fracture fixation is essential to reduce the complexity and to increase the reliability of rib osteosynthesis. Without a simple and reliable implant solution, surgical stabilization of rib fractures will remain underutilized despite proven benefits for select indications. This article summarizes the research, development, and testing of a specialized and comprehensive implant solution for rib fractur...

  5. High-precision Al-Mg isotopic systematics in USNM 3898 - The benchmark "ALL" for initial 87Sr/86Sr in the earliest Solar System

    Science.gov (United States)

    MacPherson, G. J.; Defouilloy, C.; Kita, N. T.

    2018-06-01

    The Allende CAI USNM 3898 is the basis for "ALL", the lowest measured initial 87Sr/86Sr value in any solar system material including other CAIs (Gray et al., 1973). If the value ALL is correct (debated), then USNM 3898 must be 1-2 million years older than other CAIs (Podosek et al., 1991). This would require in turn that it have a much higher initial 26Al/27Al value than other CAIs, on the order of 4 × 10-4. Podosek et al. (1991) showed that this is not the case, with initial 26Al/27Al = (4.5 ± 0.7) × 10-5, but their Mg-isotopic data had large error bars and there was clear isotopic disturbance in the data having the highest 27Al/24Mg. Without the latter data, the slope of their isochron is higher (5.10 ± 1.19) × 10-5) and within (large) error of being supracanonical. We used high-precision SIMS to re-determine the initial 26Al/27Al in this CAI and obtained a value of (5.013 ± 0.099) × 10-5, with an intercept δ26Mg* = - 0.008 ± 0.048 and MSWD = 1.3. This value is indistinguishable from that measured in many other CAIs and conclusively shows that USNM 3898 is not uniquely ancient. We also confirmed evidence of later isotopic disturbance, similar to what Podosek et al. found, indicating a re-melting and evaporation event some 200,000 years after initial CAI solidification.

  6. Five-Year Safety Data for More than 55,000 Subjects following Breast Implantation: Comparison of Rare Adverse Event Rates with Silicone Implants versus National Norms and Saline Implants.

    Science.gov (United States)

    Singh, Navin; Picha, George J; Hardas, Bhushan; Schumacher, Andrew; Murphy, Diane K

    2017-10-01

    The U.S. Food and Drug Administration has required postapproval studies of silicone breast implants to evaluate the incidence of rare adverse events over 10 years after implantation. The Breast Implant Follow-Up Study is a large 10-year study (>1000 U.S. sites) evaluating long-term safety following primary augmentation, revision-augmentation, primary reconstruction, or revision-reconstruction with Natrelle round silicone breast implants compared with national norms and outcomes with saline implants. Targeted adverse events in subjects followed for 5 to 8 years included connective tissue diseases, neurologic diseases, cancer, and suicide. The safety population comprised 55,279 women (primary augmentation, n = 42,873; revision-augmentation, n = 6837; primary reconstruction, n = 4828; and revision-reconstruction, n = 741). No targeted adverse events occurred at significantly greater rates in silicone implant groups versus national norms across all indications. The standardized incidence rate (observed/national norm) for all indications combined was 1.4 for cervical/vulvar cancer, 0.8 for brain cancer, 0.3 for multiple sclerosis, and 0.1 for lupus/lupus-like syndrome. Silicone implants did not significantly increase the risk for any targeted adverse events compared with saline implants. The risk of death was similar with silicone versus saline implants across all indications. The suicide rate (10.6 events per 100,000 person-years) was not significantly higher than the national norm. No implant-related deaths occurred. Results from 5 to 8 years of follow-up for a large number of subjects confirmed the safety of Natrelle round silicone implants, with no increased risk of systemic disease or suicide versus national norms or saline implants. Therapeutic, II.

  7. Surface modification of yttria stabilized zirconia by ion implantation

    International Nuclear Information System (INIS)

    Scholten, D.

    1987-01-01

    The results of investigations of surface modification by ion implantation in zirconia are described. As dopant material, iron was investigated thoroughly. The depth distribution of implanted ions depends on implantation parameters and the dopant-matrix system. The investigations of thermal stability of some implanted iron profiles by RBS and AES are described. Special interest lies in the thermal stability under working conditions of the zirconia material (400-1000 0 C). Radiation damage introduced in the implanted layer was investigated using transmission electron microscopy on polycrystalline material and channeling experiments on a single crystal implanted with iron. 179 refs.; 87 figs.; 20 tabs

  8. Revisiting the stability of mini-implants used for orthodontic anchorage

    Directory of Open Access Journals (Sweden)

    Chung-Chen Jane Yao

    2015-11-01

    Conclusion: This study revealed that once the dental surgeon becomes familiar with the procedure, the stability of orthodontic mini-implants depends on the type of mini-implant, age of the patient, implantation site, and the healing time of the mini-implant. Miniplates are a more feasible anchorage system when miniscrews fail repeatedly.

  9. Association between socioeconomic factors and ICD implantation in a publicly financed health care system

    DEFF Research Database (Denmark)

    Winther-Jensen, Matilde; Hassager, Christian; Lassen, Jens Flensted

    2017-01-01

    Aims: For patients surviving out-of-hospital cardiac arrest (OHCA) with a shockable rhythm, implantable cardioverter defibrillator (ICD) is recommended for non-reversible causes of arrest. We aimed to determine factors associated with implantation of ICD and survival in patients surviving non...... admission. Association to ICD implantation during index admission was analysed in logistic regression, survival was assessed using Cox regression. Implantable cardioverter defibrillator implantation increased during the study period [odds ratio (OR) 1-year increase: 1.04, 95% confidence intervals (95% CI...

  10. Chronically implanted pressure sensors: challenges and state of the field.

    Science.gov (United States)

    Yu, Lawrence; Kim, Brian J; Meng, Ellis

    2014-10-31

    Several conditions and diseases are linked to the elevation or depression of internal pressures from a healthy, normal range, motivating the need for chronic implantable pressure sensors. A simple implantable pressure transduction system consists of a pressure-sensing element with a method to transmit the data to an external unit. The biological environment presents a host of engineering issues that must be considered for long term monitoring. Therefore, the design of such systems must carefully consider interactions between the implanted system and the body, including biocompatibility, surgical placement, and patient comfort. Here we review research developments on implantable sensors for chronic pressure monitoring within the body, focusing on general design requirements for implantable pressure sensors as well as specifications for different medical applications. We also discuss recent efforts to address biocompatibility, efficient telemetry, and drift management, and explore emerging trends.

  11. Feasibility of a pre-implantation fitting test for an implantable hearing aid using a VR (virtual reality) software

    International Nuclear Information System (INIS)

    Dammann, F.; Bode, A.; Heuschmid, M.; Schwaderer, E.; Schaich, M.; Seemann, M.; Claussen, C.D.; Maassen, M.; Zenner, H.P.

    2001-01-01

    Purpose: To prove the feasibility of a preoperative fitting test for an implantable hearing aid using a VR environment. Methods: A high-resolution spiral CT was performed after mastoidectomy in 10 temporal bone specimens. The bony structures were segmented and merged with the computer-aided design (CAD) data of the hearing aid in a VR environment. For each specimen a three-dimensional fitting test was carried out by three examiners determining the implantability of the hearing aid. The implantation simulation was compared with the real implantation procedure performed by an experienced ENT surgeon. Results: The used VR system enabled real-time 3D-visualisation and manipulation of CT- and CAD-data. All objects could be independently moved in all three dimensions. The VR fitting test corresponded closely with the real implantation. The implantability of the hearing aid was properly predicted by all three examiners. Conclusion: Merging CT and CAD data in a virtual reality environment bears high potential for the presurgical determination of the fit and mountability of medical implants in complex anatomical regions. (orig.) [de

  12. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  13. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  14. Quality control of system of imaging for rectal ultrasound for implants seed prostate low rate

    International Nuclear Information System (INIS)

    Luquero Llopis, N.; Ferrer Gracia, C.; Huertas Martinez, C.; Huerga Cabrerizo, C.; Corredoira Silva, E.; Serrada Hierro, A.

    2013-01-01

    In this work, the objective is the evaluation of the image system used in implants of prostate of low rate held at our hospital, for maximum control on the placement of the seeds in the patient and therefore carried out dosimetry. (Author)

  15. Single-implant overdentures retained by the Novaloc attachment system: study protocol for a mixed-methods randomized cross-over trial.

    Science.gov (United States)

    de Souza, Raphael F; Bedos, Christophe; Esfandiari, Shahrokh; Makhoul, Nicholas M; Dagdeviren, Didem; Abi Nader, Samer; Jabbar, Areej A; Feine, Jocelyne S

    2018-04-23

    Overdentures retained by a single implant in the midline have arisen as a minimal implant treatment for edentulous mandibles. The success of this treatment depends on the performance of a single stud attachment that is susceptible to wear-related retention loss. Recently developed biomaterials used in attachments may result in better performance of the overdentures, offering minimal retention loss and greater patient satisfaction. These biomaterials include resistant polymeric matrixes and amorphous diamond-like carbon applied on metallic components. The objective of this explanatory mixed-methods study is to compare Novaloc, a novel attachment system with such characteristics, to a traditional alternative for single implants in the mandible of edentate elderly patients. We will carry out a randomized cross-over clinical trial comparing Novaloc attachments to Locators for single-implant mandibular overdentures in edentate elderly individuals. Participants will be followed for three months with each attachment type; patient-based, clinical, and economic outcomes will be gathered. A sample of 26 participants is estimated to be required to detect clinically relevant differences in terms of the primary outcome (patient ratings of general satisfaction). Participants will choose which attachment they wish to keep, then be interviewed about their experiences and preferences with a single implant prosthesis and with the two attachments. Data from the quantitative and qualitative assessments will be integrated through a mixed-methods explanatory strategy. A last quantitative assessment will take place after 12 months with the preferred attachment; this latter assessment will enable measurement of the attachments' long-term wear and maintenance requirements. Our results will lead to evidence-based recommendations regarding these systems, guiding providers and patients when making decisions on which attachment systems and implant numbers will be most appropriate for

  16. Implanted Antennas in Medical Wireless Communications

    CERN Document Server

    Rahmat-Samii, Yahya; Balanis, Constantine

    2006-01-01

    Implanted Antennas in Medical Wireless Communications summarizes the results of recent research activities on the subject of implanted antennas for medical wireless communication systems. It is anticipated that in the near future sophisticated medical devices will be implanted inside the human body for medical telemetry and telemedicine. To establish effective and efficient wireless links with these devices, it is pivotal to give special attention to antenna designs that are low profile, small, safe, and cost effective. In this book, authors Yahya Rahmat-Samii and Jaehoon Kim demonstrate how a

  17. Primary prevention of peri-implantitis: Managing peri-implant mucositis

    OpenAIRE

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; LAMBERT, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni; Schwarz, Frank; Serino, Giovanni

    2015-01-01

    Abstract AIMS: Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considere...

  18. Monitoring failure rates of commercial implant brands; substantial equivalence in question?

    Science.gov (United States)

    Hujoel, Philippe; Becker, William; Becker, Burton

    2013-07-01

    The aim of this study was to report on the failure rates of two distinct dental implant systems in a clinical practice setting. Date of implant placement and loss were entered prospectively in a data registry system. Failure rates of two commercially pure titanium implants, one with a porous oxydized surface (POS) and the other with a chemically altered surface (CAS), were assessed using a quality control chart and survival analyses. A total of 860 POS and 759 CAS implants were placed. A warning of an increased failure rate of the CAS implant was identified by means of the quality control chart. Survival analyses indicated that the CAS implant failure rate was twice that of the POS implant (Hazard Ratio: 2.08; 95% CI: 1.33-3.28, P-value POS implant was associated with a non-significant 64% drop in the implant failure rate within less than a year (HR: 0.36; 95% CI: 0.12-1.14; P-value POS implant and an 8% failure with the CAS implant appears inconsistent with the assumption of substantial equivalence. © 2012 John Wiley & Sons A/S.

  19. Osteogenesis and Morphology of the Peri-Implant Bone Facing Dental Implants

    Directory of Open Access Journals (Sweden)

    Marco Franchi

    2004-01-01

    Full Text Available This study investigated the influence of different implant surfaces on peri-implant osteogenesis and implant face morphology of peri-implant tissues during the early (2 weeks and complete healing period (3 months. Thirty endosseous titanium implants (conic screws with differently treated surfaces (smooth titanium = SS, titanium plasma sprayed = TPS, sand-blasted zirconium oxide = Zr-SLA were implanted in femur and tibiae diaphyses of two mongrel sheep. Histological sections of the implants and surrounding tissues obtained by sawing and grinding techniques were observed under light microscopy (LM. The peri-implant tissues of other samples were mechanically detached from the corresponding implants to be processed for SEM observation. Two weeks after implantation, we observed osteogenesis (new bone trabeculae around all implant surfaces only where a gap was present at the host bone-metal interface. No evident bone deposition was detectable where threads of the screws were in direct contact with the compact host bone. Distance osteogenesis predominated in SS implants, while around rough surfaces (TPS and Zr-SLA, both distance and contact osteogenesis were present. At SEM analysis 2 weeks after implantation, the implant face of SS peri-implant tissue showed few, thin, newly formed, bone trabeculae immersed in large, loose, marrow tissue with blood vessels. Around the TPS screws, the implant face of the peri-implant tissue was rather irregular because of the rougher metal surface. Zr-SLA screws showed more numerous, newly formed bone trabeculae crossing marrow spaces and also needle-like crystals in bone nodules indicating an active mineralising process. After 3 months, all the screws appeared osseointegrated, being almost completely covered by a compact, mature, newly formed bone. However, some marrow spaces rich in blood vessels and undifferentiated cells were in contact with the metal surface. By SEM analysis, the implant face of the peri-implant

  20. Amorphization of metals by ion implantation and ion beam mixing

    International Nuclear Information System (INIS)

    Rauschenbach, B.; Heera, V.

    1988-01-01

    Amorphous metallic systems can be formed either by high-fluence ion implantation of glassforming species or by irradiation of layered metal systems with inert gas ions. Both techniques and experimental examples are presented. Empirical rules are discussed which predict whether a given system can be transformed into an amorphous phase. Influence of temperature, implantation dose and pre-existing crystalline metal composition on amorphization is considered. Examples are given of the implantation induced amorphous structure, recrystallization and formation of quasicrystalline structures. (author)

  1. Implantable Medical Devices; Networking Security Survey

    Directory of Open Access Journals (Sweden)

    Siamak Aram

    2016-08-01

    Full Text Available The industry of implantable medical devices (IMDs is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable devices is rather advanced, the issue of equipping the IMDs with sufficiently strong security system remains unresolved. In fact, IMDs have relatively weak security mechanisms which render them vulnerable to cyber-attacks that compromise the quality of IMDs’ functionalities. This study revolves around the security deficiencies inherent to three types of sensor-based medical devices; biosensors, insulin pump systems and implantable cardioverter defibrillators. Manufacturers of these devices should take into consideration that security and effectiveness of the functionality of implants is highly dependent on the design. In this paper, we present a comprehensive study of IMDs’ architecture and specifically investigate their vulnerabilities at networking interface.

  2. Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features.

    Science.gov (United States)

    Cho, Sung-Yong; Huh, Yun-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    To investigate the stress distribution in an implant-abutment complex with a preloaded abutment screw by comparing implant-abutment engagement features using three-dimensional finite element analysis (FEA). For FEA modeling, two implants-one with a single (S) engagement system and the other with a double (D) engagement system-were placed in the human mandibular molar region. Two types of abutments (hexagonal, conical) were connected to the implants. Different implant models (a single implant, two parallel implants, and mesial and tilted distal implants with 1-mm bone loss) were assumed. A static axial force and a 45-degree oblique force of 200 N were applied as the sum of vectors to the top of the prosthetic occlusal surface with a preload of 30 Ncm in the abutment screw. The von Mises stresses at the implant-abutment and abutment-screw interfaces were measured. In the single implant model, the S-conical abutment type exhibited broader stress distribution than the S-hexagonal abutment. In the double engagement system, the stress concentration was high in the lower contact area of the implant-abutment engagement. In the tilted implant model, the stress concentration point was different from that in the parallel implant model because of the difference in the bone level. The double engagement system demonstrated a high stress concentration at the lower contact area of the implant-abutment interface. To decrease the stress concentration, the type of engagement features of the implant-abutment connection should be carefully considered.

  3. Sub-meninges implantation reduces immune response to neural implants.

    Science.gov (United States)

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.

  4. Polymeric implant of methylprednisolone for spinal injury ...

    African Journals Online (AJOL)

    Polymeric implant of methylprednisolone for spinal injury: preparation and characterization. Bo Yin, Jian-Jun Ji, Ming Yang. Abstract. Purpose: To improve the effectiveness and reduce the systemic side effects of methylprednisolone in traumatic spinal injuries, its polymeric implants were prepared using chitosan and sodium ...

  5. Quality assessment of pacemaker implantations in Denmark

    DEFF Research Database (Denmark)

    Møller, M; Arnsbo, P; Asklund, Mogens

    2002-01-01

    AIMS: Quality assessment of therapeutic procedures is essential to insure a cost-effective health care system. Pacemaker implantation is a common procedure with more than 500,000 implantations world-wide per year, but the general complication rate is not well described. We studied procedure relat...

  6. Progress in ion implantation equipment for semiconductor manufacturing

    International Nuclear Information System (INIS)

    Kawai, Tadashi; Naito, Masao

    1987-01-01

    In the semiconductor device manufacturing industry, ion implantation systems are used to dope semiconductor substrates with impurities that act as donor or acceptor. In an ion implantation system, required impurity ions are generated from an ion source, subjected to mass analysis, accelerated, converged and implanted in semiconductor wafers. High-tension arc tends to cause troubles in these systems, but improvement in design increased the average operation rate of medium-power systems from bout 70 percent to 90 percent during the past 10 years. Freeman type ion sources have replaced most RF ion sources and cold cathode PIG sources, which had been widely used until the early 1970s. Many of the recent ion sources are equipped with a P and As vaporizer to increase the beam intensity. By an increased beam intensity or decreased handling time in combination with an automatic handling system, the throughput has reached 330 wafers per hour for 10 second implantation. The yield has increased due to the development of improved scanning methods, vacuum devices such as cryopump, and processes and apparatus that serve for preventing particles from being contained in micro-devices. Various other improvements have been made to permit efficient production. (Nogami, K.)

  7. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search......-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  8. In Vitro Laser Treatment Platform Construction with Dental Implant Thread Surface on Bacterial Adhesion for Peri-Implantitis

    Directory of Open Access Journals (Sweden)

    Hsien-Nan Kuo

    2017-01-01

    Full Text Available This study constructs a standard in vitro laser treatment platform with dental implant thread surface on bacterial adhesion for peri-implantitis at different tooth positions. The standard clinical adult tooth jaw model was scanned to construct the digital model with 6 mm bone loss depth on behalf of serious peri-implantitis at the incisor, first premolar, and first molar. A cylindrical suite connected to the implant and each tooth root in the jaw model was designed as one experimental unit set to allow the suite to be replaced for individual bacterial adhesion. The digital peri-implantitis and suite models were exported to fulfill the physical model using ABS material in a 3D printer. A 3 mm diameter specimen implant on bacterial adhesion against Escherichia coli was performed for gram-negative bacteria. An Er:YAG laser, working with a chisel type glass tip, was moved from the buccal across the implant thread to the lingual for about 30 seconds per sample to verify the in vitro laser treatment platform. The result showed that the sterilization rate can reach 99.3% and the jaw model was not damaged after laser irradiation testing. This study concluded that using integrated image processing, reverse engineering, CAD system, and a 3D printer to construct a peri-implantitis model replacing the implant on bacterial adhesion and acceptable sterilization rate proved the feasibility of the proposed laser treatment platform.

  9. Imaging of common breast implants and implant-related complications: A pictorial essay.

    Science.gov (United States)

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  10. Influence of psychological stress on headache in patients with systemic lupus erythematosus.

    Science.gov (United States)

    Vargas-Hitos, José Antonio; Sabio, José Mario; Martínez-Egea, Isabel; Jiménez-Jáimez, Enrique; Rodríguez-Guzmán, Manuel; Navarrete-Navarrete, Nuria; López-Lozano, Esther; Romero-Alegría, Ángela; de la Calle, Cristina; Jáimez-Gámiz, Laura; Baños-Piñero, Pilar; Nebrera-Navarro, Fernando; Fidalgo, Alba; Caminal, Luis; de Ramón Garrido, Enrique; Ortego-Centeno, Norberto; Expósito, Manuela; Zamora-Pasadas, Mónica; Jiménez-Alonso, Juan

    2014-03-01

    To compare the prevalence and disability of headache in patients with systemic lupus erythematosus (SLE) with the general population and to assess the role of chronic psychological stress (CPS) in headache development. One hundred seventy patients with SLE and 102 control subjects matched for age, sex, and level of education were included in this multicenter, cross-sectional study. CPS, headache-related disability, and chronic analgesic intake (CAI) were evaluated in all participants. No statistical differences in the prevalence of headache between both groups were observed but headache disability was significantly higher in patients with SLE. In addition, a higher average score in the Cohen Perceived Stress Scale (CPSS) and a higher prevalence of patients with CAI were observed in patients with SLE. In multivariate analysis, CPSS score was positively (OR 1.09; 95% CI: 1.03-1.14; p = 0.001) and CAI negatively (OR 0.43; 95% CI: 0.19-0.99; p = 0.049) associated with headache in patients with SLE. Despite the prevalence of headache in patients with SLE and the general population being similar, headache-related disability may be higher in patients with SLE. Moreover, CPS might play a role in the pathogenesis of SLE headache, whereas CAI might have a protective effect against it.

  11. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  12. Effects of ion implantation on charges in the silicon--silicon dioxide system

    International Nuclear Information System (INIS)

    Learn, A.J.; Hess, D.W.

    1977-01-01

    Structures consisting of thermally grown oxide on silicon were implanted with boron, arsenic, or argon ions. For argon implantation through oxides, an increased fixed oxide charge (Q/sub ss/) was observed with the increase being greater for than for silicon. This effect is attributed to oxygen recoil which produces additional excess ionized silicon in the oxide of a type similar to that arising in thermal oxidation. Fast surface state (N/sub st/) generation was also noted which in most cases obscured the Q/sub ss/ increase. Of various heat treatments tested, only a 900 degreeC anneal in hydrogen annihilated N/sub st/ and allowed Q/sub ss/ measurement. Such N/sub st/ apparently arises as a consequence of implantation damage at the silicon--silicon dioxide interface. With the exception of boron implantations into thick oxides or through aluminum electrodes, reduction of the mobile ionic charge (Q/sub o/) was achieved by implantation. The reduction again is presumably damage related and is not negated by high-temperature annealing but may be counterbalanced by aluminum incorporation in the oxide

  13. Prevention and management of cochlear implant infections.

    Science.gov (United States)

    Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D

    2011-11-01

    Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.

  14. A 60 keV implanter for metals

    International Nuclear Information System (INIS)

    Leutenecker, R.; Ryssel, H.; Zeller, K.-H.; Spoehrle, H.P.

    1985-01-01

    The design and preliminary performance data of a 60 keV high current implanter for the implantation of non-separated ion beams into metals are described. The target chamber accepts samples up to 70 cm in diameter and is equipped with holders to implant ball bearings, axles and other components which have to be rotated during implantation. Samples are mounted on a rugged table which can move up to 35 kg for +-35 cm in the x and y directions. The implanter, including the vacuum system, is completely computer controlled. The ion source is equipped with an oven having a maximum temperature of 1200 0 C and can deliver ion beams of nitrogen as well as different metal ions such as tin and silver with currents up to 10 mA. (Auth.)

  15. Stresses generated by two zygomatic implant placement techniques associated with conventional inclined anterior implants

    Directory of Open Access Journals (Sweden)

    Paulo H.T. Almeida

    2018-06-01

    Full Text Available Purpose: To make a comparative evaluation, by means of the finite element method, of the stress generated on supporting tissues and prosthetic system components, using zygomatic implants with the exteriorized and extramaxillary techniques, and different placement positions, associated either with inclined anterior implants, or those without inclination. Materials and methods: Eight (8 tridimensional models were created to represent the clinical situations being researched, using the dataset of scanned images of an edentulous model. The implants and prosthetic components were photographed on millimeter paper and inserted into Rhinoceros 3D modeling computer software. From the measurements made on the image, the virtual models were made. The application force was distributed on the occlusal surface of the working side of the left maxillary first molar, first and second premolars, and incisal regions of the central incisor, simulating the occlusal load during mastication, in a total of 150 N. Results: The extramaxillary technique presented considerable variation in increased tension on the prosthesis screws and bone tissue. In the exteriorized technique, the highest tension values occurred in the region of the ridge, and the lowest, on the zygomatic process; the absence of cantilever reduced the stress on bone tissue in almost all regions. Conclusion: The exteriorized technique was shown to be more favorable to the distribution of stresses on the micro-unit screws and bone tissue, with the model with zygomatic implant placed in the region of the first molar and inclined anterior implant presenting the best results. Keywords: Zygomatic implants, Atrophic maxilla, Finite element analysis, Cantilever, Inclined implant

  16. Implantable Cardiac Pacemakers – 50 Years from the First Implantation

    Directory of Open Access Journals (Sweden)

    Ratko Magjarević

    2010-01-01

    Overview: Development of implantable cardiac pacemaker was enabled by another important invention, the silicon transistor. h ough the invention of suitable lithium cells as appropriate power supply was essential for prolongation of battery life cycle and for increased reliability of pacemakers, main milestones in the development were associated with technological breakthroughs in electronics: from transistors, which introduced such features as small size and low power consumption, to hybrid and integrated circuits, which enabled programmability, microprocessors, which added more options in programming (multiprogrammability, diagnostics and telemetry, and the ICT (information communication technology that enabled physicians remote access to patients and interrogation of their implantable devices. Conclusions: Implantable pacemakers are reliable devices indicated for a wide range of dif erent therapies of cardiac rhythm disorders and heart failure. h ere is still a lot to learn about the physiology of a normal heart and even more about the failing heart. Modern pacemakers provide physicians valuable information from pacemakers’ memory via the built-in telemetry system. h ese information help physicians to better understand pathologic processes within the heart, thus contributing to the development of new ideas for treatment of diseases and for precise tailoring of the therapy to the patient’s needs. Although implantable pacemakers have reached the level of mature technology, they will continue to develop with therapies and diagnostics to facilitate a higher quality of life.

  17. Implants in free fibula flap supporting dental rehabilitation - Implant and peri-implant related outcomes of a randomized clinical trial.

    Science.gov (United States)

    Kumar, Vinay V; Ebenezer, Supriya; Kämmerer, Peer W; Jacob, P C; Kuriakose, Moni A; Hedne, Naveen; Wagner, Wilfried; Al-Nawas, Bilal

    2016-11-01

    The objective of this study was to assess the difference in success rates of implants when using two or four implant-supported-overdentures following segmental mandibular reconstruction with fibula free flap. This prospective, parallel designed, randomized clinical study was conducted with 1:1 ratio. At baseline, all participants already had segmental reconstruction of mandible with free fibula flap. The participants were randomized into two groups: Group-I received implant-supported-overdentures on two tissue-level implants and Group-II received implant-supported-overdentures on four tissue-level implants. Success rates of the implants were evaluated at 3 months, 6 months and 12 months following implant loading using marginal bone level changes as well as peri-implant indices (Buser et al., 1990). 52 patients were randomized into two treatment groups (26 each), out of which 18 patients (36 implants) of Group-I and 17 patients (68 implants) of Group-II were evaluated. One implant in Group-I was lost due to infective complications and one patient in the same group had superior barrel necrosis. There was a statistically significant increase at both time points (p = 0.03, p = 0.04 at 6 months, 12 months) in the amount of marginal bone loss in Group-I (0.4 mm, 0.5 mm at 6 months, 12 months) as compared to Group-II (0.1 mm, 0.2 mm at 6 months, 12 months). There were no clinically significant changes peri-implant parameters between both groups. Peri-implant soft tissue hyperplasia was seen in both groups, 32% of implants at 3-months, 26% at 6-months and 3% at 12-months follow-up. The results of this study show that patients with 2-implant-supported-overdentures had higher marginal bone loss as compared to patients with 4-implant-supported-overdentures. There were no clinically significant differences in peri-implant soft tissue factors in patients with 2- or 4-implant-supported-overdentures. Hyperplastic peri-implant tissues are common in the early implant

  18. Imaging of common breast implants and implant-related complications: A pictorial essay

    Directory of Open Access Journals (Sweden)

    Amisha T Shah

    2016-01-01

    Full Text Available The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  19. General Diseases Influence on Peri-Implantitis Development: a Systematic Review

    Directory of Open Access Journals (Sweden)

    Zygimantas Guobis

    2016-09-01

    Full Text Available Objectives: To systematically review the influence of systemic diseases or medications used in their treatment on the dental implant therapy success. Material and Methods: The search strategy was implemented on the National Library of Medicine database (MEDLINE (Ovid and EMBASE electronic databases between January 2006 and January 2016. Human studies with available English articles analysing the relationship between dental implant therapy success and systemic diseases, such as diabetes mellitus, AIDS/HIV, rheumatoid arthritis, osteoporosis, Crohn’s disease, cardiovascular diseases, scleroderma, Sjögren’s syndrome, lichen planus, ectodermal dysplasia, post-transplantation status, were included in present review according to the PRISMA guidelines. The review protocol was registered on PROSPERO system with the code CRD42016033662. Results: Present review included forty one retrospective and prospective follow-up studies, case-control studies, case report series and cohort studies. Despite some limitations this study reveals positive results of implantation in most systemic conditions that should be interpreted with caution. Influence of cardiovascular diseases on the dental implantation success should be explored deeply, because of controversial results and likelihood of comorbidity expressed by a history of cardiovascular diseases and periodontitis. There is only a weak relationship with bone density in osteoporosis and implant failure. All the other diseases did not show significant effect on implantation success. Conclusions: Recent studies with low strength of evidence and controversy show that systemic diseases may have potential effect on the success of implantation, but further detailed studies are needed to provide these findings.

  20. Impact of Intentional Overload on Joint Stability of Internal Implant-Abutment Connection System with Different Diameter.

    Science.gov (United States)

    Lee, Ji-Hye; Lee, Won; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    2017-09-05

    To evaluate the axial displacement of the implant-abutment assembly of different implant diameter after static and cyclic loading of overload condition. An internal conical connection system with three diameters (Ø 4.0, 4.5, and 5.0) applying identical abutment dimension and the same abutment screw was evaluated. Axial displacement of abutment and reverse torque loss of abutment screw were evaluated under static and cyclic loading conditions. Static loading test groups were subjected to vertical static loading of 250, 400, 500, 600, 700, and 800 N consecutively. Cyclic loading test groups were subjected to 500 N cyclic loading to evaluate the effect of excessive masticatory loading. After abutment screw tightening for 30 Ncm, axial displacement was measured upon 1, 3, 10, and 1,000,000 cyclic loadings of 500 N. Repeated-measure ANOVA and 2-way ANOVA were used for statistical analysis (α = 0.05). The increasing magnitude of vertical load and thinner wall thickness of implant increased axial displacement of abutment and reverse torque loss of abutment screw (p < 0.05). Implants in the Ø 5.0 diameter group demonstrated significantly low axial displacement, and reverse torque loss after static loading than Ø 4.0 and Ø 4.5 diameter groups (p < 0.05). In the cyclic loading test, all diameter groups of implant showed significant axial displacement after 1 cycle of loading of 500 N (p < 0.05). There was no significant axial displacement after 3, 10, or 1,000,000 cycles of loading (p = 0.603). Implants with Ø 5.0 diameter demonstrated significantly low axial displacement and reverse torque loss after the cyclic and static loading of overload condition. © 2017 by the American College of Prosthodontists.

  1. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  2. Performance of conical abutment (Morse Taper) connection implants: a systematic review.

    Science.gov (United States)

    Schmitt, Christian M; Nogueira-Filho, Getulio; Tenenbaum, Howard C; Lai, Jim Yuan; Brito, Carlos; Döring, Hendrik; Nonhoff, Jörg

    2014-02-01

    In this systematic review, we aimed to compare conical versus nonconical implant-abutment connection systems in terms of their in vitro and in vivo performances. An electronic search was performed using PubMed, Embase, and Medline databases with the logical operators: "dental implant" AND "dental abutment" AND ("conical" OR "taper" OR "cone"). Names of the most common conical implant-abutment connection systems were used as additional key words to detect further data. The search was limited to articles published up to November 2012. Recent publications were also searched manually in order to find any relevant studies that might have been missed using the search criteria noted above. Fifty-two studies met the inclusion criteria and were included in this systematic review. As the data and methods, as well as types of implants used was so heterogeneous, this mitigated against the performance of meta-analysis. In vitro studies indicated that conical and nonconical abutments showed sufficient resistance to maximal bending forces and fatigue loading. However, conical abutments showed superiority in terms of seal performance, microgap formation, torque maintenance, and abutment stability. In vivo studies (human and animal) indicated that conical and nonconical systems are comparable in terms of implant success and survival rates with less marginal bone loss around conical connection implants in most cases. This review indicates that implant systems using a conical implant-abutment connection, provides better results in terms of abutment fit, stability, and seal performance. These design features could lead to improvements over time versus nonconical connection systems. © 2013 Wiley Periodicals, Inc.

  3. A controlled clinical trial of implant-retained mandibular overdentures : Clinical aspects

    NARCIS (Netherlands)

    Boerrigter, EM; VanOort, RP; Raghoebar, GM; Stegenga, B; Schoen, PJ; Boering, G

    In a controlled clinical trial, treatment effects of mandibular overdentures on two different implant-systems in edentulous patients were compared one year after insertion of the new dentures. The implant-systems used were the Branemark system (Bra) and the IMZ-system. Treatment was randomly

  4. Evaluation of an expence of materials during ion implantation

    International Nuclear Information System (INIS)

    Bannikov, M.G.; Zlobin, N.; Zotov, A.V.; Vasilev, V.I.; Vasilev, I.P.

    2003-01-01

    Ion implantation is used for a surface modification. The implantation dose must be sufficient to obtain the required properties of a processed surface, but should not be exceeded to prevent over-expenditure of implanted materials. The latter is especially important when noble metals are used as an implanted material. The ion implanter includes a vacuum chamber, source of metal ions (target) and a vacuum pumping-out system. Ions of a plasma-forming gas sputter the target and ions of metal are then accelerated and implanted into surface treated. Ion implantation dose can be calculated from operation parameters such as ion beam current density and duration of implanting. The presence of the plasma-forming gas in the ion flow makes it difficult to determine the expenditure of an implanted metal itself. The objective of this paper is the more accurate definition of an expense of an implanted metal. Mass- spectrometric analysis of an ion beam together with the weighing of the target was used to determine the expense of an implanted metal. It was found that, depending on the implantation parameters, on average around 50% of a total ion flow are metal ions. Results obtained allow more precise definition of an implantation dose. Thus, over- expenditure of implanted metals can be eliminated. (author)

  5. Low-Gain, Low-Noise Integrated Neuronal Amplifier for Implantable Artifact-Reduction Recording System

    Directory of Open Access Journals (Sweden)

    Abdelhamid Benazzouz

    2013-09-01

    Full Text Available Brain neuroprostheses for neuromodulation are being designed to monitor the neural activity of the brain in the vicinity of the region being stimulated using a single macro-electrode. Using a single macro-electrode, recent neuromodulation studies show that recording systems with a low gain neuronal amplifier and successive amplifier stages can reduce or reject stimulation artifacts. These systems were made with off-the-shelf components that are not amendable for future implant design. A low-gain, low-noise integrated neuronal amplifier (NA with the capability of recording local field potentials (LFP and spike activity is presented. In vitro and in vivo characterizations of the tissue/electrode interface, with equivalent impedance as an electrical model for recording in the LFP band using macro-electrodes for rodents, contribute to the NA design constraints. The NA occupies 0.15 mm2 and dissipates 6.73 µW, and was fabricated using a 0.35 µm CMOS process. Test-bench validation indicates that the NA provides a mid-band gain of 20 dB and achieves a low input-referred noise of 4 µVRMS. Ability of the NA to perform spike recording in test-bench experiments is presented. Additionally, an awake and freely moving rodent setup was used to illustrate the integrated NA ability to record LFPs, paving the pathway for future implantable systems for neuromodulation.

  6. Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design

    Directory of Open Access Journals (Sweden)

    Domenico Baldi

    2018-01-01

    Full Text Available Aim. To evaluate the correlation between insertion torque (IT and implant stability quotient (ISQ in tapered implants with knife-edge threads. Methods. Seventy-five identical implants (Anyridge, Megagen were inserted by using a surgical drilling unit with torque control and an integrated resonance frequency analysis module (Implantmed, W&H. IT (N/cm and ISQ were recorded and implants were divided into three groups (n=25 according to the IT: low (50. ISQ difference among groups was assessed by Kruskal-Wallis test, followed by Bonferroni-corrected Mann–Whitney U-test for pairwise comparisons. The strength of the association between IT and ISQ was assessed by Spearman Rho correlation coefficient (α=0.05. Results. At the pairwise comparisons, a significant difference of ISQ values was demonstrated only between low torque and high torque groups. The strength of the association between IT and ISQ value was significant for both the entire sample and the medium torque group, while it was not significant in low and high torque groups. Conclusions. For the investigated implant, ISQ and IT showed a positive correlation up to values around 50 N/cm: higher torques subject the bone-implant system to unnecessary biological and mechanical stress without additional benefits in terms of implant stability. This trial is registered with NCT03222219.

  7. Systemic Assessment of Calcium and Phosphorus Level after Implantation of Porous Iron in Rats

    Science.gov (United States)

    Siallagan, S. F.; Amelia, F.; Utami, N. D.; Ulum, M. F.; Boediono, A.; Estuningsih, S.; Hermawan, H.; Noviana, D.

    2017-07-01

    One of important aspects in bone healing process is physiological level of calcium (Ca), and phosphorus (P) that can be altered by implantation of biodegradable porous iron. Therefore, this study aims to investigate the concentration of Ca, P and Ca/P ratio in the peripheral blood during the implantation period up to 4 months. Forty adult male Sprague Dawley rats were used and divided into 3 groups receiving different pore size of iron implants (pore size 450, 580, 800μm) and one group of sham. The implants (5x2x0.5mm) were inserted into flat bone defects at latero-medial of femoral bone. Blood sample was taken from ventral tail artery before and after 4 month of implantation. Calcium and P concentrations in the blood were determined by BA-88A Semi-Auto Chemistry Analyzer. Results showed that concentration of Ca and P are slightly higher after implantation than before implantation, except for the 450μm group. The Ca/P ratio before and after implantation was increased in the sham group, and decreased in the 450 and 800μm groups. Concentration of Ca, P and Ca/P ratio insignificantly change between before and 4 months after surgery in some groups.

  8. Development and evaluation of totally implantable ventricular assist system using a vibrating flow pump and transcutaneous energy transmission system with amorphous fibers.

    Science.gov (United States)

    Yambe, T; Hashimoto, H; Kobayashi, S; Sonobe, T; Naganuma, S; Nanka, S S; Matsuki, H; Yoshizawa, M; Tabayashi, K; Takayasu, H; Takeda, H; Nitta, S

    1997-01-01

    We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.

  9. Evaluation of electron beam stabilization for ion implant processing

    Science.gov (United States)

    Buffat, Stephen J.; Kickel, Bee; Philipps, B.; Adams, J.; Ross, Matthew F.; Minter, Jason P.; Marlowe, Trey; Wong, Selmer S.

    1999-06-01

    With the integration of high energy ion implant processes into volume CMOS manufacturing, the need for thick resist stabilization to achieve a stable ion implant process is critical. With new photoresist characteristics, new implant end station characteristics arise. The resist outgassing needs to be addressed as well as the implant profile to ensure that the dosage is correct and the implant angle does not interfere with other underlying features. This study compares conventional deep-UV/thermal with electron beam stabilization. The electron beam system used in this study utilizes a flood electron source and is a non-thermal process. These stabilization techniques are applied to a MeV ion implant process in a CMOS production process flow.

  10. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  11. Location of unaccessible implant surface areas during debridement in simulated peri-implantitis therapy.

    Science.gov (United States)

    Steiger-Ronay, Valerie; Merlini, Andrea; Wiedemeier, Daniel B; Schmidlin, Patrick R; Attin, Thomas; Sahrmann, Philipp

    2017-11-28

    An in vitro model for peri-implantitis treatment was used to identify areas that are clinically difficult to clean by analyzing the pattern of residual stain after debridement with commonly employed instruments. Original data from two previous publications, which simulated surgical (SA) and non-surgical (NSA) implant debridement on two different implant systems respectively, were reanalyzed regarding the localization pattern of residual stains after instrumentation. Two blinded examiners evaluated standardized photographs of 360 initially ink-stained dental implants, which were cleaned at variable defect angulations (30, 60, or 90°), using different instrument types (Gracey curette, ultrasonic scaler or air powder abrasive device) and treatment approaches (SA or NSA). Predefined implant surface areas were graded for residual stain using scores ranging from one (stain-covered) to six (clean). Score differences between respective implant areas were tested for significance by pairwise comparisons using Wilcoxon-rank-sum-tests with a significance level α = 5%. Best scores were found at the machined surface areas (SA: 5.58 ± 0.43, NSA: 4.76 ± 1.09), followed by the tips of the threads (SA: 4.29 ± 0.44, NSA: 4.43 ± 0.61), and areas between threads (SA: 3.79 ± 0.89, NSA: 2.42 ± 1.11). Apically facing threads were most difficult to clean (SA: 1.70 ± 0.92, NSA: 2.42 ± 1.11). Here, air powder abrasives provided the best results. Machined surfaces at the implant shoulder were well accessible and showed least amounts of residual stain. Apically facing thread surfaces constituted the area with most residual stain regardless of treatment approach.

  12. Peri-Implant Bone Loss and Peri-Implantitis: A Report of Three Cases and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Vanchit John

    2016-01-01

    Full Text Available Dental implant supported restorations have been added substantially to the clinical treatment options presented to patients. However, complications with these treatment options also arise due to improper patient selection and inadequate treatment planning combined with poor follow-up care. The complications related to the presence of inflammation include perimucositis, peri-implant bone loss, and peri-implantitis. Prevalence rates of these complications have been reported to be as high as 56%. Treatment options that have been reported include nonsurgical therapy, the use of locally delivered and systemically delivered antibiotics, and surgical protocols aimed at regenerating the lost bone and soft tissue around the implants. The aim of this article is to report on three cases and review some of the treatment options used in their management.

  13. The effect of shape, length and diameter of implants on primary stability based on resonance frequency analysis

    Directory of Open Access Journals (Sweden)

    Hamidreza Barikani

    2014-01-01

    Full Text Available Background: The aim of this in vitro study was to evaluate the effect of shape, diameter and length of implants on their primary stability based on resonance frequency analysis. Materials and Methods: Replace select tapered and Branemark MK III implants were selected. Each of these two selected groups was divided into nine subgroups based on the implant length (IL (short, medium and long and the implant diameter (ID (narrow platform [NP], regular platform [RP] and wide platform [WP]. Five implants were assigned to each of the nine subgroups. Implants were placed in artificial bone blocks with bone quality similar to D3 bone. Immediately after the implant placement, its primary stability was measured using Osstell Mentor equipment. T-test and Tukey′s honest significant difference Post hoc were performed for data analysis. Statistical significance was defined at P < 0.05. Results: Replace select system showed significantly higher primary stability compared to the Branemark system, when using the short implants for all three diameters (P ≤ 0.004. However, in medium length implants there were no significant differences between the two implant systems (P ≥ 0.31. In long implants, only when the NP and RP implants were used, the Replace Select system showed significantly higher primary stability compared to the Branemark system (P = 0.000. In the replace select system, long implants had a significantly higher primary stability compared to medium and short length implants (P ≤ 0.003. In the NP and RP Branemark implants, short implants showed significantly lower primary stability compared to medium and long implants (P ≤ 0.002. However, in WP Branemark implants, primary stability increased significantly with increasing the IL from short to medium and from medium to long (P = 0.000. There were also significant differences between NP and the two other wider implants in both systems (P = 0.000. Conclusion: The use of tapered implants is

  14. Long time follow up of implant therapy and treatment of peri-implantitis.

    Science.gov (United States)

    Roos-Jansåker, Ann-Marie

    2007-01-01

    Dental implants have become an often used alternative to replace missing teeth, resulting in an increasing percentage of the adult population with implant supported prosthesis. Although favourable long-term results of implant therapy have been reported, infections occur. Until recently few reports included data on peri-implant infections, possibly underestimating this complication of implant treatment. It is possible that some infections around implants develop slowly and that with time peri-implantitis will be a common complication to implant therapy as an increasing number of patients have had their implants for a long time (>10 years). Data on treatment of peri-implant lesions are scarce leaving the clinician with limited guidance regarding choice of treatment. The aim of this thesis was to study the frequency of implant loss and presence of peri-implant lesions in a group of patients supplied with Brånemark implants 9-14 years ago, and to relate these events to patient and site specific characteristics. Moreover three surgical treatment modalities for peri-implantitis were evaluated. The thesis is based on six studies; Studies I-III included 218 patients and 1057 implants followed for 9-14 years evaluating prevalence of, and factors related to implant loss (Paper I) and prevalence of peri-implant infections and related factors (Paper I-III). Study IV is a review describing different treatment modalities of peri-implant infections. Study V is a prospective cohort study involving 36 patients and 65 implants, evaluating the use of a bone substitute with or without the use of a resorbable membrane. Study VI is a case series with 12 patients and 16 implants, evaluating a bone substitute in combination with a resorbable membrane and submerged healing. This thesis demonstrated that: After 9-14 years the survival rates of dental implants are high (95.7%). Implant loss seems to cluster within patients and are related to periodontitis evidenced as bone loss on

  15. Silicone breast implants and connective tissue disease

    DEFF Research Database (Denmark)

    Lipworth, Loren; Holmich, Lisbet R; McLaughlin, Joseph K

    2011-01-01

    The association of silicone breast implants with connective tissue diseases (CTDs), including systemic sclerosis, systemic lupus erythematosus, rheumatoid arthritis, and fibromyalgia, as well as a hypothesized new "atypical" disease, which does not meet established diagnostic criteria for any known...... CTD, has been extensively studied. We have reviewed the epidemiologic literature regarding an association between cosmetic breast implants and CTDs, with particular emphasis on results drawn from the most recent investigations, many of which are large cohort studies with long-term follow-up, as well...... as on those studies that address some of the misinformation and historically widespread claims regarding an association between breast implants and CTDs. These claims have been unequivocally refuted by the remarkably consistent evidence from published studies, as well as numerous independent meta...

  16. Oral Rehabilitation with Implant-Retained Overdenture in a Patient with Down Syndrome.

    Science.gov (United States)

    Altintas, Nuray Yilmaz; Kilic, Serdar; Altintas, Subutay Han

    2017-01-24

    Down syndrome, known as trisomy 21, is the most common chromosomal disorder. The disorder affects mental and systemic development as well as oral structure, including dental anomalies, high susceptibility of periodontal disease, and poor quality of alveolar bone. This report presents a case of dental rehabilitation by means of dental implants of a patient with Down syndrome. Two titanium dental implants were placed in the maxilla, and three titanium dental implants were installed in the mandible. One implant was lost during the osseointegration period. The prosthetic rehabilitation was performed with implant-retained maxillary and mandibular overdentures with the Locator attachment system. After a 2-year follow-up period, the patient was doing well, and all implants were clinically stable with no signs of bone loss or inflammation. The present study emphasizes that implant-retained overdentures with Locator attachment system could be a therapeutic option even for patients with Down syndrome. This therapy prevents crestal bone loss around the implants, improves functional and esthetic outcomes, and provides optimum oral hygiene for patients with mild mental impairment. Careful patient selection and education of patients and caregivers are essential considerations for a successful and safe treatment with dental implants in Down syndrome patients. © 2017 by the American College of Prosthodontists.

  17. Current concepts of regenerative biomaterials in implant dentistry

    Directory of Open Access Journals (Sweden)

    Annapurna Ahuja

    2015-01-01

    Full Text Available The primary objective of any implant system is to achieve firm fixation to the bone and this could be influenced by biomechanical as well as biomaterial selection. An array of materials is used in the replacement of missing teeth through implantation. The appropriate selection of biomaterials directly influences the clinical success and longevity of implants. Thus the clinician needs to have adequate knowledge of the various biomaterials and their properties for their judicious selection and application in his/her clinical practice. The recent materials such as bioceramics and composite biomaterials that are under consideration and investigation have a promising future. For optimal performance, implant biomaterials should have suitable mechanical strength, biocompatibility, and structural biostability in the physiological environment. This article reviews the various implant biomaterials and their ease of use in implant dentistry.

  18. The Effect of Breast Implants on Mammogram Outcomes.

    Science.gov (United States)

    Kam, Kelli; Lee, Esther; Pairawan, Seyed; Anderson, Kendra; Cora, Cherie; Bae, Won; Senthil, Maheswari; Solomon, Naveenraj; Lum, Sharon

    2015-10-01

    Breast cancer detection in women with implants has been questioned. We sought to evaluate the impact of breast implants on mammographic outcomes. A retrospective review of women undergoing mammography between March 1 and October 30, 2013 was performed. Demographic characteristics and mammogram results were compared between women with and without breast implants. Overall, 4.8 per cent of 1863 women identified during the study period had breast implants. Median age was 59 years (26-93). Women with implants were younger (53.9 vs 59.2 years, P breast tissue (72.1% vs 56.4%, P = 0.004) than those without. There were no statistically significant differences with regards to Breast Imaging Recording and Data System 0 score (13.3% with implants vs 21.4% without), call back exam (18.9% with vs 24.1% without), time to resolution of abnormal imaging (58.6 days with vs 43.3 without), or cancer detection rate (0% with implants vs 1.0% without). Because implants did not significantly affect mammogram results, women with implants should be reassured that mammography remains useful in detecting cancer. However, future research is required to determine whether lower call back rates and longer time to resolution of imaging findings contribute to delays in diagnosis in patients with implants.

  19. Systemic Sclerosis and Silicone Breast Implant: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Antonios Psarras

    2014-01-01

    Full Text Available Environmentally induced systemic sclerosis is a well-recognized condition, which is correlated with exposure to various chemical compounds or drugs. However, development of scleroderma-like disease after exposure to silicone has always been a controversial issue and, over time, it has triggered spirited debate whether there is a certain association or not. Herein, we report the case of a 35-year-old female who developed Raynaud’s phenomenon and, finally, systemic sclerosis shortly after silicone breast implantation surgery.

  20. Electromechanical impedance method to assess dental implant stability

    International Nuclear Information System (INIS)

    Tabrizi, Aydin; Rizzo, Piervincenzo; Ochs, Mark W

    2012-01-01

    The stability of a dental implant is a prerequisite for supporting a load-bearing prosthesis and establishment of a functional bone–implant system. Reliable and noninvasive methods able to assess the bone interface of dental and orthopedic implants (osseointegration) are increasingly demanded for clinical diagnosis and direct prognosis. In this paper, we propose the electromechanical impedance method as a novel approach for the assessment of dental implant stability. Nobel Biocare ® implants with a size of 4.3 mm diameter ×13 mm length were placed inside bovine bones that were then immersed in a solution of nitric acid to allow material degradation. The degradation simulated the inverse process of bone healing. The implant–bone systems were monitored by bonding a piezoceramic transducer (PZT) to the implants’ abutment and measuring the admittance of the PZT over time. It was found that the PZT’s admittance and the statistical features associated with its analysis are sensitive to the degradation of the bones and can be correlated to the loss of calcium measured by means of the atomic absorption spectroscopy method. The present study shows promising results and may pave the road towards an innovative approach for the noninvasive monitoring of dental implant stability and integrity. (paper)

  1. Prosthetic implant treatment of the edentulous maxilla with overdenture.

    Science.gov (United States)

    Inversini, M

    2006-10-01

    The literature concerning the success of prosthetic implant treatment with maxillary overdenture is reviewed, and variables affecting treatment from the implant and prosthetic standpoint are analysed. Guidelines for the fabrication of maxillary overimplants comparable to those for mandibular overimplants are still lacking, as are evidence-based prosthetic design concepts. Individual methods and techniques have been described, but evaluation standards for the outcome of maxillary prosthetic-implant treatment are lacking or individually interpreted. The biomechanics involved in the proposed system are described, together with the advantages of telescopic crowns for the retention of removable partial prosthesis supported by maxillary implants. The positive influence, in terms of long-term prognosis, of the perio-protective design of removable partial prostheses supported by maxillary overimplants is also discussed. The proposed system not only provides stability, support and retention for removable partial prostheses supported by maxillary implants, but also enables implant survival rates to be improved, both for biomechanical reasons and due to improved oral hygiene. The simplification of fabrication procedures, repair, rebasing and re-operating also reduce the cost of follow-up and improve the cost/benefit ratio. However, additional studies are needed to clarify the number and most appropriate distribution of implants, as well as the most favourable prosthetic designs for maxillary overimplants.

  2. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  3. Functional adaptation of the masticatory system to implant-supported mandibular overdentures.

    Science.gov (United States)

    Giannakopoulos, Nikolaos Nikitas; Corteville, Frédéric; Kappel, Stefanie; Rammelsberg, Peter; Schindler, Hans Jürgen; Eberhard, Lydia

    2017-05-01

    The purpose of this study was to investigate the adaptation behavior of the stomatognathic system after immediate loading (24 to 72 h after surgery) of two implants supporting mandibular overdentures, assessed on insertion and three months later. The study hypothesis was that insertion of the overdentures would significantly change masticatory performance and muscle activity at both times. Thirty subjects (nine female, mean age 69.64 ± 11.81 years; 21 male, mean age 68.67 ± 7.41 years) who participated in a randomized clinical trial were included in the study. Each patient was examined three times: (i) at baseline, after already having worn new dentures for three months (T1); (ii) immediately after insertion of the overdentures on the implants (T2); and (iii) after an adaptation period of three months (T3). Examination comprised assessment of masticatory performance with artificial test food (Optocal), and simultaneous bilateral surface EMG recording of the masseter and anterior temporalis muscles. Particle-size distribution (representative value X 50 ), maximum muscle contraction (MVC), and total muscle work (TMW; area under the curve) were compared by use of repeated-measures analysis of variance (ANOVA). At T3, all measured variables (i.e., masticatory performance and muscle activity) were significantly different from those at T1. At T2, no significant changes were observed. The study hypothesis had to be rejected for T2 but accepted for T3. Functional rehabilitation (in terms of masticatory performance and masticatory muscle activity) does not occur immediately after immediate loading of two implants with mandibular overdentures, but requires a significant time for functional improvement. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. [Operative treatment of proximal humeral four-part fractures in elderly patients: comparison of two angular-stable implant systems].

    Science.gov (United States)

    Kuhlmann, T; Hofmann, T; Seibert, O; Gundlach, G; Schmidt-Horlohé, K; Hoffmann, R

    2012-04-01

    Although being one of the most common fractures in elderly patients, there is still no standardised treatment protocol for four-part fractures of the proximal humerus. However, a wide variety of angular-stable implants is available. The present retrospective study compares the clinical and radiological outcome following operative treatment of four-part fractures of the proximal humerus with the Philos system (Philos, proximal humeral internal locking system, Synthes GmbH, Umkirch Germany) and the angular-stable Königsee plate system (Königsee Implantate GmbH, Allendorf, Germany) in patients older than 65 years. From July 2005 until December 2007 we identified 77 patients with a four-part fracture of the proximal humerus who were treated operatively with one of the two implant systems. Of the patients, 17 could not be located so that in total 60 patients (78 %) participated in this study. The mean age of the 30 patients (10 m, 20 f) in the Philos group was 69 years (65-92), whereas the mean age of the 30 patients (11 m, 19 f) in the Königsee group was 71 years (65-93). A comprehensive assessment was performed after a median of 17 months (12-24), including physical examination, radiographic examination and completion of the disabilities of the arm, shoulder and hand score (DASH) and the Constant score (CS) as patient-oriented, limb-specific questionnaires. Neither in the Philos nor in the Königsee group could excellent results be achieved. Using the CS 13 patients (43 %) of the Philos group achieved a good and 15 (50 %) a satisfactory result. Bad results were found in 2 patients (7 %). The mean CS was 61.53 points. In the Königsee group mean CS was 61.76 points. In detail, 14 patients (47 %) treated with the Königsee implant were rated as good and 15 (50 %) as satisfactory. Only 1 patient (3 %) was rated as poor. No significant statistical differences were found between the groups. Mean DASH score in the Philos group was 56.30 points and 55.37 points in the K

  5. Use of antibiotic beads to salvage infected breast implants.

    Science.gov (United States)

    Sherif, Rami D; Ingargiola, Michael; Sanati-Mehrizy, Paymon; Torina, Philip J; Harmaty, Marco A

    2017-10-01

    When an implant becomes infected, implant salvage is often performed where the implant is removed, capsulectomy is performed, and a new implant is inserted. The patient is discharged with a PICC line and 6-8 weeks of intravenous (IV) antibiotics. This method has variable success and subjects the patient to long-term systemic antibiotics. In the 1960s, the use of antibiotic-impregnated beads for the treatment of chronic osteomyelitis was described. These beads deliver antibiotic directly to the site of the infection, thereby eliminating the complications of systemic IV antibiotics. This study aimed to present a case series illustrating the use of STIMULAN calcium sulfate beads loaded with vancomycin and tobramycin to increase the rate of salvage of the infected implant and forgo IV antibiotics. A retrospective analysis was performed of patients who were treated at Mount Sinai Hospital for implant infection with salvage and antibiotic beads. Twelve patients were identified, 10 of whom had breast cancer. Comorbidities included hypertension, smoking, and immunocompromised status. Infections were noted anywhere from 5 days to 8 years postoperatively. Salvage was successful in 9 out of the 12 infected implants using antibiotic bead therapy without home IV antibiotics. The use of antibiotic beads is promising for salvaging infected breast implants without IV antibiotics. Seventy-five percent of the implants were successfully salvaged. Of the three patients who had unsalvageable implants, one was infected with antibiotic-resistant Rhodococcus that was refractory to bead therapy and one was noncompliant with postoperative instructions. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Comparison of dual-time-constant and fast-acting automatic gain control (AGC) systems in cochlear implants.

    Science.gov (United States)

    Boyle, Patrick J; Büchner, Andreas; Stone, Michael A; Lenarz, Thomas; Moore, Brian C J

    2009-04-01

    Cochlear implants usually employ an automatic gain control (AGC) system as a first stage of processing. AGC1 was a fast-acting (syllabic) compressor. AGC2 was a dual-time-constant system; it usually performed as a slow-acting compressor, but incorporated an additional fast-acting system to provide protection from sudden increases in sound level. Six experienced cochlear-implant users were tested in a counterbalanced order, receiving one-month of experience with a given AGC type before switching to the other type. Performance was evaluated shortly after provision of a given AGC type and after one-month of experience with that AGC type. Questionnaires, mainly relating to listening in quiet situations, did not reveal significant differences between the two AGC types. However, fixed-level and roving-level tests of sentence identification in noise both revealed significantly better performance for AGC2. It is suggested that the poorer performance for AGC1 occurred because AGC1 introduced cross-modulation between the target speech and background noise, which made perceptual separation of the target and background more difficult.

  7. An Implanted, Stimulated Muscle Powered Piezoelectric Generator

    Science.gov (United States)

    Lewandowski, Beth; Gustafson, Kenneth; Kilgore, Kevin

    2007-01-01

    A totally implantable piezoelectric generator system able to harness power from electrically activated muscle could be used to augment the power systems of implanted medical devices, such as neural prostheses, by reducing the number of battery replacement surgeries or by allowing periods of untethered functionality. The features of our generator design are no moving parts and the use of a portion of the generated power for system operation and regulation. A software model of the system has been developed and simulations have been performed to predict the output power as the system parameters were varied within their constraints. Mechanical forces that mimic muscle forces have been experimentally applied to a piezoelectric generator to verify the accuracy of the simulations and to explore losses due to mechanical coupling. Depending on the selection of system parameters, software simulations predict that this generator concept can generate up to approximately 700 W of power, which is greater than the power necessary to drive the generator, conservatively estimated to be 50 W. These results suggest that this concept has the potential to be an implantable, self-replenishing power source and further investigation is underway.

  8. Influence of implant number on the movement of mandibular implant overdentures.

    Science.gov (United States)

    Oda, Ken; Kanazawa, Manabu; Takeshita, Shin; Minakuchi, Shunsuke

    2017-03-01

    The rotational movement of an implant overdenture (IOD) has a negative effect on the perceived masticatory ability of the denture wearer. However, the influence of implant number on the movement of IODs has not been investigated. The purpose of this in vitro study was to evaluate the denture movement of mandibular IODs anchored by different numbers of implants. An edentulous mandibular test model with artificial mucosa and 5 experimental overdentures (N=5) was fabricated. The locator attachment system with blue nylon inserts was chosen for this study. Three implant positions were prepared: anterior midline (1-IOD), bilateral lateral incisor regions (2-IOD), and anterior midline and bilateral canine regions (3-IOD). Vertical loads of 50 N were applied to the mid-anterior region, the left canine region, the left premolar region, and the left first molar region. The vertical and horizontal displacements at the right distal edge and the vertical displacements at the loading point were measured. The displacement values were statistically analyzed using a 1-way analysis of variance and the post hoc Tukey honest significant difference test with the implant number as a factor. In addition, the values of the vertical and horizontal displacements at the distal edge of the overdenture were statistically compared using a paired t test, and the values of the vertical displacement at the distal edge of the overdenture were statistically analyzed by a repeated measures analysis of variance and the post hoc Tukey honest significance difference test with the loading point as a factor (a=.05). Upon anterior loading, the 2-IOD showed significantly larger vertical displacements at the right distal edge than the 1-IOD or 3-IOD (P.05). Within the limitations of this in vitro study, the following conclusions were drawn: During mastication with the anterior teeth, the use of 2 implants for anchoring an IOD increased the rotation of the denture base more than the use of 1 or 3 implants

  9. Device-length changes and implant function following surgical implantation of the KineSpring in cadaver knees

    Directory of Open Access Journals (Sweden)

    McNicholas MJ

    2015-01-01

    Full Text Available Michael J McNicholas,1 Stefan M Gabriel,2 Anton G Clifford,2 Evelyne M Hasler2 1Aintree University Hospital, Teaching Hospital, Major Trauma Centre, NHS Foundation Trust, Liverpool, UK; 2Moximed, Hayward, CA, USA Introduction: The KineSpring implant system has been shown to provide load reductions at the medial compartment of the knee, and has demonstrated clinical success in reducing pain and increasing function in patients with medial knee osteoarthritis. These results depend on the ability of the KineSpring to rotate, lengthen, and shorten to accommodate knee motions, and in response to knee position and loading. Purpose: The present study was undertaken to determine length changes of the implanted KineSpring in response to a range of knee positions, external knee loads, and placements by different orthopedic surgeons. Materials and methods: KineSpring system components were implanted in ten cadaver leg specimens by ten orthopedic surgeons, and absorber-length changes were measured under combined loading and in different positions of the knee. Results and conclusion: Spring compression consistent with knee-load reduction, and device lengthening and shortening to accommodate knee loads and motions were seen. These confirm the functionality of the KineSpring when implanted medially to the knee. Keywords: KineSpring, knee, function, preservation, offloading, osteoarthritis

  10. Dental Implants in an Aged Population: Evaluation of Periodontal Health, Bone Loss, Implant Survival, and Quality of Life.

    Science.gov (United States)

    Becker, William; Hujoel, Philippe; Becker, Burton E; Wohrle, Peter

    2016-06-01

    To evaluate aged partially and fully edentulous patients who received dental implants and were maintained over time. Further, to determine how the partially and edentulous ageing populations (65 and above) with dental implants maintain bone levels, proper oral hygiene, and perceive benefits of dental implants. Since 1995, patients receiving dental implants have been prospectively entered into an Access-based computerized program (Triton Tacking System). Patient demographics (age, sex), bone quality, quantity, implant location, and type of surgery have been continuously entered into the database. The database was queried for patients receiving implants (first stage) between 66 and 93 years of age. Thirty-one patients were within this age group. Twenty-five patients returned to the clinic for periodontal and dental implant evaluation. The Periodontal Index was used to evaluate selected teeth in terms of probing depth, bleeding on probing, plaque accumulation, and mobility. Using NIH Image J, radiographs taken at second stage and last examination were measured for changes in interproximal bone levels. Once identified, each patient anomalously filled out an abbreviated quality of health life form. Due to small sample size, descriptive statistics were used to compare clinical findings. Fifteen males ranging from 78 to 84 (mean age 84 years) years and 16 females from 66 to 93 (mean age 83 years) (age range 66-93) were contacted by phone or mail and asked to return to our office for a re-examination. For this group, the first dental implants were placed in 1996 (n = initial two implants) and continuously recorded through 2013 (n = last seven implants). Thirty-one patients received a total of 84 implants. Two patients were edentulous, and the remaining were partially edentulous. Four implants were lost. Between implant placement and 6- to 7-year interval, 13 patients with 40 implants had a cumulative survival rate of 94.6%. Of the original group (n = 33), three

  11. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  12. Technical tips during implantation of selective upper airway stimulation.

    Science.gov (United States)

    Heiser, Clemens; Thaler, Erica; Soose, Ryan J; Woodson, B Tucker; Boon, Maurits

    2018-03-01

    Selective upper airway stimulation is now well-established in the United States and in several European countries, with more than 1,000 patients implanted since U.S. Food and Drug Administration approval in April 2014. The authors herein, all head and neck surgeons, account for approximately one of every five implants completed to date. Several of the authors also provide comprehensive longitudinal care of their patients as dual-specialty sleep medicine physicians. Multi-center, retrospective clinical analysis. More than 300 implants have been evaluated and reviewed in five different implant centers (Germany, United States). This analysis shares tips and techniques from the collective experiences with more than 300 implants, which can help newer implanters learn vicariously both for standard practices in executing routine implants through activation and, importantly, for working through more challenging encounters with anatomy, special patient phenotypes, system testing, and troubleshooting. These tips should help new implanters handle most of the situations arising during implantation and avoid common pitfalls. Laryngoscope, 128:756-762, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Mobile User Objective System (MUOS)

    Science.gov (United States)

    2015-12-01

    the current UHF Follow-On ( UFO ) constellation. MUOS includes the satellite constellation, a ground control and network management system, and a new...MUOS CAI. Each MUOS satellite carries a legacy payload similar to that flown on UFO -11. These legacy payloads will continue to support legacy...Antecedent Information The antecedent system to MUOS was the Ultra High Frequency (UHF) Follow-on ( UFO ) satellite communications program. Comparisons

  14. A 10-year randomized clinical trial on the influence of splinted and unsplinted oral implants retaining mandibular overdentures: peri-implant outcome.

    Science.gov (United States)

    Naert, Ignace; Alsaadi, Ghada; van Steenberghe, Daniel; Quirynen, Marc

    2004-01-01

    This randomized controlled clinical trial aimed to evaluate the efficacy of splinted implants versus unsplinted implants in overdenture therapy over a 10-year period. The study sample comprised 36 completely edentulous patients, 17 men and 19 women (mean age 63.7 years). In each patient, 2 implants (Brånemark System, Nobel Biocare, Göteborg, Sweden) were placed in the interforaminal area. Three to 5 months after placement, they were connected to standard abutments. The patients were then rehabilitated with ball-retained overdentures, magnet-retained overdentures, or bar-retained overdentures (the control group). Patients were followed for 4, 12, 60, and 120 months post-abutment connection. Group means as well as linear regression models were fitted with attachment type and time as classification variables and corrected for simultaneous testing (Tukey). After 10 years, 9 patients had died and 1 was severely ill. Over 10 years, no implants failed. Mean Plaque Index, Bleeding Index, change in attachment level, Periotest values, and marginal bone level at the end of the follow-up period were not significantly different among the groups. The annual marginal bone loss, excluding the first months of remodeling, was comparable with that found around healthy natural teeth. The fact that no implants failed and that overall marginal bone loss after the first year of bone remodeling was limited suggested that implants in a 2-implant mandibular overdenture concept have an excellent prognosis in this patient population, irrespective of the attachment system used.

  15. Dosimetric measurement of scattered radiation from dental implants in simulated head and neck radiotherapy.

    Science.gov (United States)

    Wang, R; Pillai, K; Jones, P K

    1998-01-01

    The purpose of this study was to examine the dose enhancement at bone-implant interfaces from scattered radiation during simulated head and neck radiotherapy. Three cylindric implant systems with different compositions (pure titanium, titanium-aluminum-vanadium alloy, titanium coated with hydroxyapatite) and a high gold content transmandibular implant system (gold-copper-silver alloy) were studied. Extruded lithium fluoride single crystal chips were used as thermoluminescent material to measure radiation dose enhancement at 0, 1, and 2 mm from the bone-implant interface. The relative doses in buccal, lingual, mesial, and distal directions were also recorded and compared. The results indicated that the highest dose enhancement occurred at a distance of 0 mm from the bone-implant interface for all the implant systems studied. The transmandibular implants had higher scattered radiation than other groups at 0 mm and at 1 mm from the bone-implant interface. There was no significant difference of dose enhancement between buccal, lingual, mesial, and distal directions. Titanium implants coated with hydroxyapatite demonstrated the best results under the simulated irradiation.

  16. [Carbon fiber-reinforced plastics as implant materials].

    Science.gov (United States)

    Bader, R; Steinhauser, E; Rechl, H; Siebels, W; Mittelmeier, W; Gradinger, R

    2003-01-01

    Carbon fiber-reinforced plastics have been used clinically as an implant material for different applications for over 20 years.A review of technical basics of the composite materials (carbon fibers and matrix systems), fields of application,advantages (e.g., postoperative visualization without distortion in computed and magnetic resonance tomography), and disadvantages with use as an implant material is given. The question of the biocompatibility of carbon fiber-reinforced plastics is discussed on the basis of experimental and clinical studies. Selected implant systems made of carbon composite materials for treatments in orthopedic surgery such as joint replacement, tumor surgery, and spinal operations are presented and assessed. Present applications for carbon fiber reinforced plastics are seen in the field of spinal surgery, both as cages for interbody fusion and vertebral body replacement.

  17. ERP IMPLANTATION: KEY FACTORS OF SUCCESS AND IMPACT ON PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Dumitru Valentin

    2008-05-01

    Full Text Available The implantation of an ERP (abbreviation for "Enterprise Resource Planning" system is an enterprise project that implies the remodeling of the information system, mostly the rethinking of management procedures within the organization. The expansion and the complexity of these projects demand a theoretical framework and « optimal practices » in order to model and to evaluate the key factors of implementation success and to analyze its impact on the organization’s performance. The research problem of our communication can be divided into three research questions: - What conceptual framework for ERP implantation? - What are the key factors of success in ERP implantation? - What is the relationship between ERP implantation and enterprise performance?

  18. Treatment Alternatives to Negotiate Peri-Implantitis

    Directory of Open Access Journals (Sweden)

    Eli E. Machtei

    2014-01-01

    Full Text Available Peri-implant diseases are becoming a major health issue in dentistry. Despite the magnitude of this problem and the potential grave consequences, commonly acceptable treatment protocols are missing. Hence, the present paper reviews the literature treatment of peri-implantitis in order to explore their benefits and limitations. Treatment of peri-implantitis may include surgical and nonsurgical approaches, either individually or combined. Nonsurgical therapy is aimed at removing local irritants from the implants’ surface with or without surface decontamination and possibly some additional adjunctive therapies agents or devices. Systemic antibiotics may also be incorporated. Surgical therapy is aimed at removing any residual subgingival deposits and additionally reducing the peri-implant pockets depth. This can be done alone or in conjunction with either osseous respective approach or regenerative approach. Finally, if all fails, explantation might be the best alternative in order to arrest the destruction of the osseous structure around the implant, thus preserving whatever is left in this site for future reconstruction. The available literature is still lacking with large heterogeneity in the clinical response thus suggesting possible underlying predisposing conditions that are not all clear to us. Therefore, at present time treatment of peri-implantitis should be considered possible but not necessarily predictable.

  19. Does the number of implants have any relation with peri-implant disease?

    Directory of Open Access Journals (Sweden)

    Bernardo Born PASSONI

    2014-10-01

    Full Text Available Objective: The aim of this study was to evaluate the relationship between the number of pillar implants of implant-supported fixed prostheses and the prevalence of periimplant disease. Material and Methods: Clinical and radiographic data were obtained for the evaluation. The sample consisted of 32 patients with implant-supported fixed prostheses in function for at least one year. A total of 161 implants were evaluated. Two groups were formed according to the number of implants: G1 ≤5 implants and G2 >5 implants. Data collection included modified plaque index (MPi, bleeding on probing (BOP, probing depth (PD, width of keratinized mucosa (KM and radiographic bone loss (BL. Clinical and radiographic data were grouped for each implant in order to conduct the diagnosis of mucositis or peri-implantitis. Results: Clinical parameters were compared between groups using Student’s t test for numeric variables (KM, PD and BL and Mann-Whitney test for categorical variables (MPi and BOP. KM and BL showed statistically significant differences between both groups (p<0.001. Implants from G1 – 19 (20.43% – compared with G2 – 26 (38.24% – showed statistically significant differences regarding the prevalence of peri-implantitis (p=0.0210. Conclusion: It seems that more than 5 implants in total fixed rehabilitations increase bone loss and consequently the prevalence of implants with periimplantitis. Notwithstanding, the number of implants does not have any influence on the prevalence of mucositis.

  20. Prospects of ion implantation and ion beam mixing for corrosion protection

    International Nuclear Information System (INIS)

    Wolf, G.K.; Munn, P.; Ensinger, W.

    1985-01-01

    Ion implantation is very useful new low temperature treatment for improving the mechanical surface properties of materials without any dimensional changes. In addition also the corrosion properties of metals can be modified considerably by this technique. The long term corrosion behaviour of implanted metals, however, has been studied only for a very limited number of cases. In this contribution a survey of attempts to do this will be presented. As examples of promising systems for corrosion protection by ion beams iron, steel and titanium were examined with and without pretreatment by ion implantation and ion beam mixing. The corrosion rates of the systems have been obtained by neutron activation analysis and by electrochemical methods. Experimental results are presented on: Palladium implanted in titanium - crevice corrosion in salt solution; Palladium implanted in and deposited on titanium -corrosion in sulfuric acid; Platinum implanted in stainless steel -corrosion in sulfuric acid. (author)

  1. Development and implantation of application systems for reduction and analysis of experimental data in Nuclear Physics area

    International Nuclear Information System (INIS)

    Cardoso Junior, J.L.; Schelin, H.R.; Lemos, B.J.K.C.; Tanaka, E.H.; Castro, A.T.C.G.

    1984-01-01

    Several application systems for reduction and analysis of experimental data are described. These codes were development and/or implanted in tee IEAv/CTA CYBER 170/750 system. A brief description of the experimental data acquisition modes and the necessary reduction for analysis is given. Information on the purposes, uses and access of the codes are given [pt

  2. Bird community structure in riparian environments in Cai River, Rio Grande do Sul, Brazil

    Directory of Open Access Journals (Sweden)

    Jaqueline Brummelhaus

    2012-06-01

    Full Text Available Urbanization produces changes in riparian environments, causing effects in the structure of bird communities, which present different responses to the impacts. We compare species richness, abundance, and composition of birds in riparian environments with different characteristics in Cai River, Rio Grande do Sul, Brazil. We carried out observations in woodland, grassland, and urban environments, between September 2007 and August 2008. We listed 130 bird species, 29 species unique to woodland environment, and an endangeredspecies: Triclaria malachitacea. Bird abundance differed from woodland (n = 426 individuals to urban environments (n = 939 individuals (F2,6 = 7.315; P = 0.025. Species composition and feeding guilds differed significantly in the bird community structures among these three riparian environments. In the grassland and urban environments there were more generalist insectivorous species, while in the woodland environments we find more leaf and trunk insectivorous species and frugivorous species, sensitive to human impacts. Bird species can be biological quality indicators and they contribute to ecosystems performing relevant functions. With the knowledge on bird community structure and their needs, it is possible to implement management practices for restoration of degraded riparian environments.

  3. Tribological properties of nitrogen implanted and boron implanted steels

    International Nuclear Information System (INIS)

    Kern, K.T.

    1996-01-01

    Samples of a steel with high chrome content was implanted separately with 75 keV nitrogen ions and with 75 keV boron ions. Implanted doses of each ion species were 2-, 4-, and 8 x 10 17 /cm 2 . Retained doses were measured using resonant non-Rutherford Backscattering Spectrometry. Tribological properties were determined using a pin-on-disk test with a 6-mm diameter ruby pin with a velocity of 0.94 m/min. Testing was done at 10% humidity with a load of 377 g. Wear rate and coefficient of friction were determined from these tests. While reduction in the wear rate for nitrogen implanted materials was observed, greater reduction (more than an order of magnitude) was observed for boron implanted materials. In addition, reduction in the coefficient of friction for high-dose boron implanted materials was observed. Nano-indentation revealed a hardened layer near the surface of the material. Results from grazing incidence x-ray diffraction suggest the formation of Fe 2 N and Fe 3 N in the nitrogen implanted materials and Fe 3 B in the boron implanted materials. Results from transmission electron microscopy will be presented

  4. Cochlear implantation in late-implanted adults with prelingual deafness.

    Science.gov (United States)

    Most, Tova; Shrem, Hadas; Duvdevani, Ilana

    2010-01-01

    The purpose of this study was to examine the effect of cochlear implantation (CI) on prelingually deafened participants who were implanted as adults. The effect of the CI was examined with regard to the following variables: communication, family, social skills, education, and work satisfaction with one's life, loneliness, and self-esteem. Thirty-eight adults participated. Four self-report questionnaires were used at 2 points in time: before and after CI. The research findings show significant differences in the reports of most variables before and after implantation. The participants felt better with regard to communication, social skills, education, and work and satisfaction with one's life after implantation in comparison to their feelings before implantation. Furthermore, they felt less lonely after implantation. However, there were no significant differences before and after implantation regarding their feelings within the family and regarding their self-esteem. The results demonstrated the need to evaluate the benefits resulting from the CI not only with traditional clinical measures but with additional measures as well. Furthermore, they demonstrated the benefit of the CI on the positive psychosociological implications of prelingually deafened adults. Copyright © 2010 Elsevier Inc. All rights reserved.

  5. Histology of a dental implant with a platform switched implant-abutment connection

    Directory of Open Access Journals (Sweden)

    Vittoria Perrotti

    2011-10-01

    Full Text Available Background: Peri-implant crestal bone must be stable for aesthetic reasons. Aim of this study was a histologic analysis of an implant with a platform switched implant-abutment connection. Materials and methods: A 32-year-old male patient participated in this study. The patient needed a bilateral mandibular restoration. Four implants were used, and were immediately restored and loaded the same day of insertion. After a 6 weeks healing period, one implant with platform-switched abutment was retrieved with trephine. Before retrieval the implant was osseointegrated and not mobile. On one side of the implant, a 1 mm resorption of the crestal bone was present. On the contrary, on the other side no bone resorption had occurred and about 1 mm of bone was present over the implant shoulder. Results: The bone-implant contact percentage was 65.1 ± 6.3 %. Platform- switching could help in maintaining the height of the peri-implant crestal bone.

  6. Safety of implantable pacemakers and cardioverter defibrillators in the magnetic field of a novel remote magnetic navigation system.

    Science.gov (United States)

    Jilek, Clemens; Tzeis, Stylianos; Reents, Tilko; Estner, Heidi-Luise; Fichtner, Stephanie; Ammar, Sonia; Wu, Jinjin; Hessling, Gabriele; Deisenhofer, Isabel; Kolb, Christof

    2010-10-01

    Electromagnetic interference with pacemaker and implantable cardioverter defibrillator (ICD) systems may cause temporary or permanent system malfunction of implanted devices. The aim of this study was to evaluate potential interference of a novel magnetic navigation system with implantable rhythm devices. A total of 121 devices (77 pacemakers, 44 ICDs) were exposed to an activated NIOBE II® Magnetic Navigation System (Stereotaxis, St. Louis, MO, USA) at the maximal magnetic field strength of 0.1 Tesla and evaluated in vitro with respect to changes in parameter settings of the device, changes of the battery status/detection of elective replacement indication, or alterations of data stored in the device. A total of 115 out of 121 (95%) devices were free of changes in parameter settings, battery status, and internally stored data after repeated exposition to the electromagnetic field of the remote magnetic navigation system. Interference with the magnetic navigation field was observed in 6 pacemakers, resulting in reprogramming to a power-on-reset mode with or without detection of the elective replacement indication in 5 devices and abnormal variance of battery status in one device. All pacemakers could be reprogrammed to the initial modes and the battery status proved to be normal some minutes after the pacemakers had been removed from the magnetic field. Interference of a remote magnetic navigation system (at maximal field strength) with pacemakers and ICDs not connected to leads with antitachycardic detection and therapies turned off is rare. Occurring functional abnormalities could be reprogrammed in our sample. An in vitro study will give information about interference of devices connected to leads. © 2010 Wiley Periodicals, Inc.

  7. Effectiveness of Implant Therapy Analyzed in a Swedish Population: Prevalence of Peri-implantitis.

    Science.gov (United States)

    Derks, J; Schaller, D; Håkansson, J; Wennström, J L; Tomasi, C; Berglundh, T

    2016-01-01

    Peri-implantitis is an inflammatory disease affecting soft and hard tissues surrounding dental implants. As the global number of individuals that undergo restorative therapy through dental implants increases, peri-implantitis is considered as a major and growing problem in dentistry. A randomly selected sample of 588 patients who all had received implant-supported therapy 9 y earlier was clinically and radiographically examined. Prevalence of peri-implantitis was assessed and risk indicators were identified by multilevel regression analysis. Forty-five percent of all patients presented with peri-implantitis (bleeding on probing/suppuration and bone loss >0.5 mm). Moderate/severe peri-implantitis (bleeding on probing/suppuration and bone loss >2 mm) was diagnosed in 14.5%. Patients with periodontitis and with ≥4 implants, as well as implants of certain brands and prosthetic therapy delivered by general practitioners, exhibited higher odds ratios for moderate/severe peri-implantitis. Similarly, higher odds ratios were identified for implants installed in the mandible and with crown restoration margins positioned ≤1.5 mm from the crestal bone at baseline. It is suggested that peri-implantitis is a common condition and that several patient- and implant-related factors influence the risk for moderate/severe peri-implantitis (ClinicalTrials.gov NCT01825772). © International & American Associations for Dental Research 2015.

  8. Reliability of a CAD/CAM Surgical Guide for Implant Placement: An In Vitro Comparison of Surgeons' Experience Levels and Implant Sites.

    Science.gov (United States)

    Park, Su-Jung; Leesungbok, Richard; Cui, Taixing; Lee, Suk Won; Ahn, Su-Jin

    This in vitro study evaluated the reliability of a surgical guide with regard to different levels of operator surgical experience and implant site. A stereolithographic surgical guide for epoxy resin mandibles with three edentulous molar sites was produced using a computer-aided design/computer-assisted manufacture (CAD/CAM) system. Two surgeons with and two surgeons without implant surgery experience placed implants in a model either using or not using the CAD/CAM surgical guide. Four groups were created: inexperienced surgeon without the guide (group 1); experienced surgeon without the guide (group 2); inexperienced surgeon with the guide (group 3); and experienced surgeon with the guide (group 4). Planned implants and placed implants were superimposed using digital software, and deviation parameters were calculated. There were no significant differences in any of the deviation parameters between the groups when using the surgical guide. With respect to the implant sites, there were no significant differences among the groups in any parameter. Use of the CAD/CAM surgical guide reduced discrepancies among operators performing implant surgery regardless of their level of experience. Whether or not the guide was used, differences in the anterior-posterior implant site in the molar area did not affect the accuracy of implant placement.

  9. Bilateral Poly Implant Prothèse Implant Rupture: An Uncommon Presentation

    Directory of Open Access Journals (Sweden)

    Peter Mallon

    2013-07-01

    Full Text Available Summary: A woman in her 50s underwent delayed bilateral Poly Implant Prothèse implant reconstruction following mastectomy for breast cancer. Symptoms of implant rupture developed 43 months after surgery with an erythematous rash on her trunk. The rash then spread to her reconstructed breast mounds. Initial ultrasound scan and magnetic resonance imaging were normal; however, subsequent magnetic resonance imaging demonstrated left implant rupture only. In theater, following removal of both implants, both were found to be ruptured. The rash on her trunk resolved within 3 weeks in the postoperative period. Chemical analyses of silicone in both implants confirmed a nonauthorized silicone source; in addition, the chemical structure was significantly different between the left and right implant, perhaps explaining the variation in presentation.

  10. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  11. Management of peri-implantitis

    Directory of Open Access Journals (Sweden)

    Jayachandran Prathapachandran

    2012-01-01

    Full Text Available Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of color in the gingiva, bleeding and probing depth of peri-implant pockets, suppuration, X-ray, and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of peri-implant mucositis or peri-implantitis. The management of implant infection should be focused on the control of infection, the detoxification of the implant surface, and regeneration of the alveolar bone. This review article deals with the various treatment options in the management of peri-implantitis. The article also gives a brief description of the etiopathogenesis, clinical features, and diagnosis of peri-implantitis.

  12. Peri-implant soft tissue and marginal bone adaptation on implant with non-matching healing abutments: micro-CT analysis.

    Science.gov (United States)

    Finelle, Gary; Papadimitriou, Dimitrios E V; Souza, André B; Katebi, Negin; Gallucci, German O; Araújo, Mauricio G

    2015-04-01

    To assess (i) the outcome of changing the horizontal-offset dimension on the peri-implant soft tissues and the crestal bone and (ii) the effect of different healing abutments (flared vs. straight) on the marginal peri-implant soft tissues and crestal bone. Two-piece dental implants diameters of 3.5 and 4.5 mm were placed at least 1 mm subcrestal in five beagle dogs. Three different investigational groups: (i) 3.5-mm-diameter implant with narrow healing abutment (3.5N), (ii) 4.5-mm-diameter implant with narrow healing abutment (4.5N), and (iii) 3.5-mm-diameter implant with wide healing abutment (3.5W), were assessed. After 4 months of healing, the vertical distance from the marginal crestal bone (MB) to the implant shoulder (IS); the vertical distance from the IS to the first bone-to-implant contact; and the horizontal distance of bone ingrowth on the implant platform were measured with a high-resolution micro-CT (Xradia MicroXCT-200 system). Implants with a narrow healing caps showed an interproximal MB located between 0 and 1 mm above the implant shoulder, while the 3.5W group exhibits a mean value -0.50 mm. As all implants in group 3.5N presented a fBIC located at the level of the IS. For the 4.5N group, the mean fBIC-IS distance was -0.52 mm apically to the IS. For the 3.5WC group, the mean fBIC-IS distance was -1.42 mm. Horizontal bone apposition was only observed for the 3.5N group and the 4.5N group. The dimension of the horizontal offset would play a minimal role in reducing bone remodeling, whereas the configuration of the transmucosal component would directly influence marginal bone remodeling. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Power Approaches for Implantable Medical Devices

    Directory of Open Access Journals (Sweden)

    Achraf Ben Amar

    2015-11-01

    Full Text Available Implantable medical devices have been implemented to provide treatment and to assess in vivo physiological information in humans as well as animal models for medical diagnosis and prognosis, therapeutic applications and biological science studies. The advances of micro/nanotechnology dovetailed with novel biomaterials have further enhanced biocompatibility, sensitivity, longevity and reliability in newly-emerged low-cost and compact devices. Close-loop systems with both sensing and treatment functions have also been developed to provide point-of-care and personalized medicine. Nevertheless, one of the remaining challenges is whether power can be supplied sufficiently and continuously for the operation of the entire system. This issue is becoming more and more critical to the increasing need of power for wireless communication in implanted devices towards the future healthcare infrastructure, namely mobile health (m-Health. In this review paper, methodologies to transfer and harvest energy in implantable medical devices are introduced and discussed to highlight the uses and significances of various potential power sources.

  14. Experimental study on bone tissue reaction around HA implants radiated after implantation

    International Nuclear Information System (INIS)

    Kudo, Masato; Matsui, Yoshiro; Tamura, Sayaka; Chen, Xuan; Uchida, Haruo; Mori, Kimie; Ohno, Kohsuke; Michi, Ken-ichi

    1998-01-01

    This study was conducted to investigate histologically and histomorphometrically the tissue reaction around hydroxylapatite (HA) implants that underwent irradiation in 3 different periods in the course of bone healing after implantation. The cylindrical high-density HA implants were implanted in 48 Japanese white rabbit mandibles. A single 15 Gy dose was applied to the mandible 5, 14, or 28 days after implantation. The rabbits were sacrificed 7, 14, 28, and 90 days after irradiation. Nonirradiated rabbits were used as controls. CMR, labeling with tetracycline and calcein, and non-decalcified specimens stained with toluidine blue were used for histological analyses and histomorphometric measurements. The results were as follows: In the rabbits irradiated 5 days after implantation, the HA-bone contact was observed later than that in the controls and the bone-implant contact surface ratio was lower than that in the controls at examination because necrosis of the newly-formed bone occurred just after irradiation. HA-bone contact of the rabbits irradiated 14 and 28 days after implantation was similar to that of the controls. And, bone remodeling was suppressed in rabbits of each group sacrificed at 90 days after irradiation. The results suggested that a short interval between implantation and irradiation causes direct contact between HA implant and bone and a long lapse of time before irradiation hardly affects the bone-implant contact, but delays bone remodeling. Therefore, it is necessary to prevent overloading the HA implants irradiated after implantation and pay utmost attention to conditions around the bone-implant contact. (author)

  15. Split-Framework in Mandibular Implant-Supported Prosthesis

    Directory of Open Access Journals (Sweden)

    Danny Omar Mendoza Marin

    2015-01-01

    Full Text Available During oral rehabilitation of an edentulous patient with an implant-supported prosthesis, mandibular flexure must be considered an important biomechanical factor when planning the metal framework design, especially if implants are installed posterior to the interforaminal region. When an edentulous mandible is restored with a fixed implant-supported prosthesis connected by a fixed full-arch framework, mandibular flexure may cause needless stress in the overall restorative system and lead to screw loosening, poor fit of prosthesis, loss of the posterior implant, and patient’s discomfort due to deformation properties of the mandible during functional movements. The use of a split-framework could decrease the stress with a precise and passive fit on the implants and restore a more natural functional condition of the mandible, helping in the longevity of the prosthesis. Therefore, the present clinical report describes the oral rehabilitation of an edentulous patient by a mandibular fixed implant-supported prosthesis with a split-framework to compensate for mandibular flexure. Clinical Significance. The present clinical report shows that the use of a split-framework reduced the risk of loss of the posterior implants or screws loosening with acceptable patient comfort over the period of a year. The split-framework might have compensated for the mandibular flexure during functional activities.

  16. Brainjacking: Implant Security Issues in Invasive Neuromodulation.

    Science.gov (United States)

    Pycroft, Laurie; Boccard, Sandra G; Owen, Sarah L F; Stein, John F; Fitzgerald, James J; Green, Alexander L; Aziz, Tipu Z

    2016-08-01

    The security of medical devices is critical to good patient care, especially when the devices are implanted. In light of recent developments in information security, there is reason to be concerned that medical implants are vulnerable to attack. The ability of attackers to exert malicious control over brain implants ("brainjacking") has unique challenges that we address in this review, with particular focus on deep brain stimulation implants. To illustrate the potential severity of this risk, we identify several mechanisms through which attackers could manipulate patients if unauthorized access to an implant can be achieved. These include blind attacks in which the attacker requires no patient-specific knowledge and targeted attacks that require patient-specific information. Blind attacks include cessation of stimulation, draining implant batteries, inducing tissue damage, and information theft. Targeted attacks include impairment of motor function, alteration of impulse control, modification of emotions or affect, induction of pain, and modulation of the reward system. We also discuss the limitations inherent in designing implants and the trade-offs that must be made to balance device security with battery life and practicality. We conclude that researchers, clinicians, manufacturers, and regulatory bodies should cooperate to minimize the risk posed by brainjacking. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. One-stage explant-implant procedure of exposed porous orbital implants

    DEFF Research Database (Denmark)

    Toft, Peter B; Rasmussen, Marie L Roed; Prause, Jan Ulrik

    2011-01-01

    Purpose:  To investigate the risks of implant exposure after a combined explant-implant procedure in patients with an exposed porous orbital implant. Methods:  Twenty-four consecutive patients who had a combined explant-implant procedure of an exposed hydroxyapatite (21) or porous polyethylene (3...... at the same procedure in sockets without profound signs of infection. The procedure carries a possible risk of poor motility....

  18. Ion implantation as an efficient surface treatment

    International Nuclear Information System (INIS)

    Straede, C.A.

    1992-01-01

    Ion beam processing has for several years been well established in the semiconductor industry. In recent years ion implantation of tool steels, ceramics and even plastics has gained increasing industrial awareness. The development of ion implantation to a commercially viable surface treatment of tools and spare parts working in production type environments is very dependent on technical merits, economic considerations, competing processes and highly individual barriers to acceptance for each particular application. Some examples of this will be discussed. The development of the process is very closely linked with the development of high current accelerators and their ability to efficiently manipulate the samples being treated, or to make sample manipulation superfluous by using special beam systems like the PSII. Furthermore, the ability to produce high beam currents (mA) of a wide variety of ions is crucial. Previously, it was broadly accepted that ion implantation of tools on a commercial basis generally had to be limited to nitrogen implantation. The development of implanters which can produce high beam currents of ions like B + , C + , Ti + , Cr + and others is rapidly changing this situation, and today an increasing number of commercial implantations are performed with these ions although nitrogen is still successfully used in the majority of commercial implantation. All in all, the recent development of equipment makes it possible to a higher extent than before to tailor the implantation to a specific situation. The emerging new possibilities in this direction will be discussed, and a broad selection of practical examples of ion implantation at standard low temperatures of tools and spare parts will be given. Furthermore, very interesting results have been obtained recently by implanting nitrogen at elevated temperatures, which yields a relatively deep penetration of the implanted ions. (orig./WL)

  19. Development of the CAI system for inheritance of maintenance expertise

    International Nuclear Information System (INIS)

    Hanafusa, Hidemitsu; Chigusa, Naoki; Furuta, Kazuo

    2002-01-01

    High quality maintenance is required in order to secure the safety of nuclear power plants. The engineers engaged in maintenance activities have to master various knowledge, including the explicit and tacit knowledge of experienced experts, through education and training. Moreover, it is also very important to prevent these knowledge from getting scattered and lost with a change of generation and to share the knowledge or expertise. The purpose of this study is to develop a support system for the next generation experts to help them master and make use of the knowledge of their predecessors. The knowledge or expertise consist of ''knowledge about the maintenance tasks'', ''knowledge about structure/function of plant system/equipment'', and ''individual knowledge based on trouble experience etc.''. The ways this knowledge could be represented were considered first, then this support system was developed based on such representation. (author)

  20. Wireless power transfer and data communication for neural implants case study : epilepsy monitoring

    CERN Document Server

    Yilmaz, Gürkan

    2017-01-01

    This book presents new circuits and systems for implantable biomedical applications targeting neural recording. The authors describe a system design adapted to conform to the requirements of an epilepsy monitoring system. Throughout the book, these requirements are reflected in terms of implant size, power consumption, and data rate. In addition to theoretical background which explains the relevant technical challenges, the authors provide practical, step-by-step solutions to these problems. Readers will gain understanding of the numerical values in such a system, enabling projections for feasibility of new projects. Provides complete, system-level perspective for implantable batteryless biomedical system; Extends design example to implementation and long term in-vitro validation; Discusses system design concerns regarding wireless power transmission and wireless data communication, particularly for systems in which both are performed on the same channel/frequency; Presents fully-integrated, implantable syste...

  1. Spinal shape modulation in a porcine model by a highly flexible and extendable non-fusion implant system

    NARCIS (Netherlands)

    Wessels, Martijn; Hekman, Edsko E G; Kruyt, Moyo C.; Castelein, RM; Homminga, Jasper J.; Verkerke, Gijsbertus J.

    2016-01-01

    Purpose: In vivo evaluation of scoliosis treatment using a novel approach in which two posterior implants are implanted: XSLAT (eXtendable implant correcting Scoliosis in LAT bending) and XSTOR (eXtendable implant correcting Scoliosis in TORsion). The highly flexible and extendable implants use only

  2. Mathematical Analysis of a PDE System for Biological Network Formation

    KAUST Repository

    Haskovec, Jan; Markowich, Peter A.; Perthame, Benoit

    2015-01-01

    Motivated by recent physics papers describing rules for natural network formation, we study an elliptic-parabolic system of partial differential equations proposed by Hu and Cai [13, 15]. The model describes the pressure field thanks to Darcy's type

  3. The Pathology of Orthopedic Implant Failure Is Mediated by Innate Immune System Cytokines

    OpenAIRE

    Landgraeber, Stefan; Jäger, Marcus; Jacobs, Joshua J.; Hallab, Nadim James

    2014-01-01

    All of the over 1 million total joint replacements implanted in the US each year are expected to eventually fail after 15–25 years of use, due to slow progressive subtle inflammation at the bone implant interface. This inflammatory disease state is caused by implant debris acting, primarily, on innate immune cells, that is, macrophages. This slow progressive pathological bone loss or “aseptic loosening” is a potentially life-threatening condition due to the serious complications in older peop...

  4. Placement of fin type dental implant in three different surgical situations of alveolar bone

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2007-03-01

    Full Text Available Three different dental implant placements according to surgical implant bed situations were observed in its bone integration 3 months after dental implant insertion. This observation was done on implant system which has plateau or fin system. Elf implants were placed in the upper jaw in two patients. In case one, two implants were inserted immediately after tooth extraction, and the other six implants were placed in the alveolar crest regions in delayed implantation or in which the teeth had been extracted over 6 months of period. In case two, three implants were inserted in the post trauma region in the anterior maxilla, which the labial plate had been lost and reconstructed with bone grafting procedure using a mixture of alloplastic and autogenous bones. The alveolar reconstruction was needed to be performed due to only thin alveolar crest width was left intact. All of those implants observed showed in good integration.

  5. [Electromagnetic fields of mobile telephone systems--thresholds, effects and risks for cochlear implant patients and healthy people].

    Science.gov (United States)

    Bischof, F; Langer, J; Begall, K

    2008-11-01

    Every day life is detectably affected by manifold natural sources of electromagnetic fields (EMF), e. g. infrared radiation, light and the terrestrial magnetic field. However, there is still uncertainty about the consequences or hazards of artificial EMF, which emerge from mobile phone or wireless network (wireless local area network [WLAN]) services, for instance. Following recommendations of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) the German Commission on Radiation Protection (SSK) defined corresponding thresholds for high frequency electromagnetic fields (HF-EMF) in 2003. By observing those thresholds HF-EMF is thought to be innocent so far. However, there is still controversial discussion about induction of cancer or neurovegetative symptoms due to inconsistent study results. Patients with cochlea implants are of particular interest within the speciality of otorhinolaryngology due to specific hazards, which arise during mobile telephone use from the distance between brain and inductive metal implants (electrode) on the one hand and the electronic system of the cochlear implant and the source of HF-EMF on the other hand. Besides many studies about the impact of HF-EMF on common welfare, there are only very few surveys (n = 6) covering the effects on patients with cochlear implants. The purpose of this paper is to overview sources, thresholds and subsequently harmful or harmless effects of HFEMF. Due to the current state of knowledge about the impact of mobile phone use on health, we assume, that HF-EMF are harmless both for healthy people and patients with cochlea implants, provided that legal thresholds are observed.

  6. Toward a distributed free-floating wireless implantable neural recording system.

    Science.gov (United States)

    Pyungwoo Yeon; Xingyuan Tong; Byunghun Lee; Mirbozorgi, Abdollah; Ash, Bruce; Eckhardt, Helmut; Ghovanloo, Maysam

    2016-08-01

    To understand the complex correlations between neural networks across different regions in the brain and their functions at high spatiotemporal resolution, a tool is needed for obtaining long-term single unit activity (SUA) across the entire brain area. The concept and preliminary design of a distributed free-floating wireless implantable neural recording (FF-WINeR) system are presented, which can enabling SUA acquisition by dispersedly implanting tens to hundreds of untethered 1 mm3 neural recording probes, floating with the brain and operating wirelessly across the cortical surface. For powering FF-WINeR probes, a 3-coil link with an intermediate high-Q resonator provides a minimum S21 of -22.22 dB (in the body medium) and -21.23 dB (in air) at 2.8 cm coil separation, which translates to 0.76%/759 μW and 0.6%/604 μW of power transfer efficiency (PTE) / power delivered to a 9 kΩ load (PDL), in body and air, respectively. A mock-up FF-WINeR is implemented to explore microassembly method of the 1×1 mm2 micromachined silicon die with a bonding wire-wound coil and a tungsten micro-wire electrode. Circuit design methods to fit the active circuitry in only 0.96 mm2 of die area in a 130 nm standard CMOS process, and satisfy the strict power and performance requirements (in simulations) are discussed.

  7. Development of a simple, low cost, indirect ion beam fluence measurement system for ion implanters, accelerators

    Science.gov (United States)

    Suresh, K.; Balaji, S.; Saravanan, K.; Navas, J.; David, C.; Panigrahi, B. K.

    2018-02-01

    We developed a simple, low cost user-friendly automated indirect ion beam fluence measurement system for ion irradiation and analysis experiments requiring indirect beam fluence measurements unperturbed by sample conditions like low temperature, high temperature, sample biasing as well as in regular ion implantation experiments in the ion implanters and electrostatic accelerators with continuous beam. The system, which uses simple, low cost, off-the-shelf components/systems and two distinct layers of in-house built softwarenot only eliminates the need for costly data acquisition systems but also overcomes difficulties in using properietry software. The hardware of the system is centered around a personal computer, a PIC16F887 based embedded system, a Faraday cup drive cum monitor circuit, a pair of Faraday Cups and a beam current integrator and the in-house developed software include C based microcontroller firmware and LABVIEW based virtual instrument automation software. The automatic fluence measurement involves two important phases, a current sampling phase lasting over 20-30 seconds during which the ion beam current is continuously measured by intercepting the ion beam and the averaged beam current value is computed. A subsequent charge computation phase lasting 700-900 seconds is executed making the ion beam to irradiate the samples and the incremental fluence received by the sampleis estimated usingthe latest averaged beam current value from the ion beam current sampling phase. The cycle of current sampling-charge computation is repeated till the required fluence is reached. Besides simplicity and cost-effectiveness, other important advantages of the developed system include easy reconfiguration of the system to suit customisation of experiments, scalability, easy debug and maintenance of the hardware/software, ability to work as a standalone system. The system was tested with different set of samples and ion fluences and the results were verified using

  8. Clinical implementation of stereotaxic brain implant optimization

    International Nuclear Information System (INIS)

    Rosenow, U.F.; Wojcicka, J.B.

    1991-01-01

    This optimization method for stereotaxic brain implants is based on seed/strand configurations of the basic type developed for the National Cancer Institute (NCI) atlas of regular brain implants. Irregular target volume shapes are determined from delineation in a stack of contrast enhanced computed tomography scans. The neurosurgeon may then select up to ten directions, or entry points, of surgical approach of which the program finds the optimal one under the criterion of smallest target volume diameter. Target volume cross sections are then reconstructed in 5-mm-spaced planes perpendicular to the implantation direction defined by the entry point and the target volume center. This information is used to define a closed line in an implant cross section along which peripheral seed strands are positioned and which has now an irregular shape. Optimization points are defined opposite peripheral seeds on the target volume surface to which the treatment dose rate is prescribed. Three different optimization algorithms are available: linear least-squares programming, quadratic programming with constraints, and a simplex method. The optimization routine is implemented into a commercial treatment planning system. It generates coordinate and source strength information of the optimized seed configurations for further dose rate distribution calculation with the treatment planning system, and also the coordinate settings for the stereotaxic Brown-Roberts-Wells (BRW) implantation device

  9. Computer-assisted intraoperative visualization of dental implants. Augmented reality in medicine

    International Nuclear Information System (INIS)

    Ploder, O.; Wagner, A.; Enislidis, G.; Ewers, R.

    1995-01-01

    In this paper, a recently developed computer-based dental implant positioning system with an image-to-tissue interface is presented. On a computer monitor or in a head-up display, planned implant positions and the implant drill are graphically superimposed on the patient's anatomy. Electromagnetic 3D sensors track all skull and jaw movements; their signal feedback to the workstation induces permanent real-time updating of the virtual graphics' position. An experimental study and a clinical case demonstrates the concept of the augmented reality environment - the physician can see the operating field and superimposed virtual structures, such as dental implants and surgical instruments, without loosing visual control of the operating field. Therefore, the operation system allows visualization of CT planned implantposition and the implementation of important anatomical structures. The presented method for the first time links preoperatively acquired radiologic data, planned implant location and intraoperative navigation assistance for orthotopic positioning of dental implants. (orig.) [de

  10. Analysis of induced electrical currents from magnetic field coupling inside implantable neurostimulator leads

    Directory of Open Access Journals (Sweden)

    Seidman Seth J

    2011-10-01

    Full Text Available Abstract Background Over the last decade, the number of neurostimulator systems implanted in patients has been rapidly growing. Nearly 50, 000 neurostimulators are implanted worldwide annually. The most common type of implantable neurostimulators is indicated for pain relief. At the same time, commercial use of other electromagnetic technologies is expanding, making electromagnetic interference (EMI of neurostimulator function an issue of concern. Typically reported sources of neurostimulator EMI include security systems, metal detectors and wireless equipment. When near such sources, patients with implanted neurostimulators have reported adverse events such as shock, pain, and increased stimulation. In recent in vitro studies, radio frequency identification (RFID technology has been shown to inhibit the stimulation pulse of an implantable neurostimulator system during low frequency exposure at close distances. This could potentially be due to induced electrical currents inside the implantable neurostimulator leads that are caused by magnetic field coupling from the low frequency identification system. Methods To systematically address the concerns posed by EMI, we developed a test platform to assess the interference from coupled magnetic fields on implantable neurostimulator systems. To measure interference, we recorded the output of one implantable neurostimulator, programmed for best therapy threshold settings, when in close proximity to an operating low frequency RFID emitter. The output contained electrical potentials from the neurostimulator system and those induced by EMI from the RFID emitter. We also recorded the output of the same neurostimulator system programmed for best therapy threshold settings without RFID interference. Using the Spatially Extended Nonlinear Node (SENN model, we compared threshold factors of spinal cord fiber excitation for both recorded outputs. Results The electric current induced by low frequency RFID emitter

  11. Adaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review.

    Science.gov (United States)

    Bocan, Kara N; Sejdić, Ervin

    2016-03-18

    Wireless energy transfer is a broad research area that has recently become applicable to implantable medical devices. Wireless powering of and communication with implanted devices is possible through wireless transcutaneous energy transfer. However, designing wireless transcutaneous systems is complicated due to the variability of the environment. The focus of this review is on strategies to sense and adapt to environmental variations in wireless transcutaneous systems. Adaptive systems provide the ability to maintain performance in the face of both unpredictability (variation from expected parameters) and variability (changes over time). Current strategies in adaptive (or tunable) systems include sensing relevant metrics to evaluate the function of the system in its environment and adjusting control parameters according to sensed values through the use of tunable components. Some challenges of applying adaptive designs to implantable devices are challenges common to all implantable devices, including size and power reduction on the implant, efficiency of power transfer and safety related to energy absorption in tissue. Challenges specifically associated with adaptation include choosing relevant and accessible parameters to sense and adjust, minimizing the tuning time and complexity of control, utilizing feedback from the implanted device and coordinating adaptation at the transmitter and receiver.

  12. Adaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review

    Directory of Open Access Journals (Sweden)

    Kara N. Bocan

    2016-03-01

    Full Text Available Wireless energy transfer is a broad research area that has recently become applicable to implantable medical devices. Wireless powering of and communication with implanted devices is possible through wireless transcutaneous energy transfer. However, designing wireless transcutaneous systems is complicated due to the variability of the environment. The focus of this review is on strategies to sense and adapt to environmental variations in wireless transcutaneous systems. Adaptive systems provide the ability to maintain performance in the face of both unpredictability (variation from expected parameters and variability (changes over time. Current strategies in adaptive (or tunable systems include sensing relevant metrics to evaluate the function of the system in its environment and adjusting control parameters according to sensed values through the use of tunable components. Some challenges of applying adaptive designs to implantable devices are challenges common to all implantable devices, including size and power reduction on the implant, efficiency of power transfer and safety related to energy absorption in tissue. Challenges specifically associated with adaptation include choosing relevant and accessible parameters to sense and adjust, minimizing the tuning time and complexity of control, utilizing feedback from the implanted device and coordinating adaptation at the transmitter and receiver.

  13. Higher complication risk of totally implantable venous access port systems in patients with advanced cancer - a single institution retrospective analysis.

    Science.gov (United States)

    Chang, Yi-Fang; Lo, An-Chi; Tsai, Chung-Hsin; Lee, Pei-Yi; Sun, Shen; Chang, Te-Hsin; Chen, Chien-Chuan; Chang, Yuan-Shin; Chen, Jen-Ruei

    2013-02-01

    Totally implantable port systems are generally recommended for prolonged central venous access in diverse settings, but their risk of complications remains unclear for patients with advanced cancer. The aim of this study was to assess the risk of port system failure in patients with advanced cancer. We conducted a retrospective cohort study in a comprehensive cancer centre. A detailed chart review was conducted among 566 patients with 573 ports inserted during January-June, 2009 (average 345.3 catheter-days). Cox regression analysis was applied to evaluate factors during insertion and early maintenance that could lead to premature removal of the port systems due to infection or occlusion. Port system-related infection was significantly associated with receiving palliative care immediately after implantation (hazard ratio, HR = 7.3, 95% confidence interval, 95% CI = 1.2-46.0), after adjusting for probable confounders. Primary cancer site also impacted the occurrence of device-related infection. Receiving oncologic/palliative care (HR = 3.0, P = 0.064), advanced cancer stage (HR = 6.5, P = 0.077) and body surface area above 1.71 m(2) (HR = 3.4, P = 0.029) increased the risk of port system occlusion. Our study indicates that totally implantable port systems yield a higher risk of complications in terminally ill patients. Further investigation should be carefully conducted to compare outcomes of various central venous access devices in patients with advanced cancer and to develop preventive strategies against catheter failure.

  14. The effect of metallic implants on radiation therapy in spinal tumor patients with metallic spinal implants.

    Science.gov (United States)

    Son, Seok Hyun; Kang, Young Nam; Ryu, Mi-Ryeong

    2012-01-01

    The aim of this study was to evaluate the effect of metallic implants on the dose calculation for radiation therapy in patients with metallic implants and to find a way to reduce the error of dose calculation. We made a phantom in which titanium implants were inserted into positions similar to the implant positions in spinal posterior/posterolateral fusion. We compared the calculated dose of the treatment planning systems with the measured dose in the treatment equipment. We used 3 kinds of computed tomography (CT) (kilovoltage CT, extended-scaled kilovoltage CT, and megavoltage CT) and 3 kinds of treatment equipment (ARTISTE, TomoTherapy Hi-Art, and Cyberknife). For measurement of doses, we used an ionization chamber and Gafchromic external beam therapy film. The absolute doses that were measured using an ionization chamber at the isocenter in the titanium phantom were on average 1.9% lower than those in the reference phantom (p = 0.002). There was no statistically significant difference according to the kinds of CT images, the treatment equipment, and the size of the targets. As the distance from the surface of the titanium implants became closer, the measured doses tended to decrease (p metallic implants was less in the megavoltage CT than in the kilovoltage CT or the extended-scaled kilovoltage CT. The error caused by the titanium implants was beyond a clinically acceptable range. To reduce the error of dose calculation, we suggest that the megavoltage CT be used for planning. In addition, it is necessary to consider the distance between the titanium implants and the targets or the organs at risk to prescribe the dose for the target and the dose constraint for the organs at risk. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  15. Physicochemical and microscopic characterization of implant-abutment joints.

    Science.gov (United States)

    Lopes, Patricia A; Carreiro, Adriana F P; Nascimento, Rubens M; Vahey, Brendan R; Henriques, Bruno; Souza, Júlio C M

    2018-01-01

    The purpose of this study was to investigate Morse taper implant-abutment joints by chemical, mechanical, and microscopic analysis. Surfaces of 10 Morse taper implants and the correlated abutments were inspected by field emission gun-scanning electron microscopy (FEG-SEM) before connection. The implant-abutment connections were tightened at 32 Ncm. For microgap evaluation by FEG-SEM, the systems were embedded in epoxy resin and cross-sectioned at a perpendicular plane of the implant-abutment joint. Furthermore, nanoindentation tests and chemical analysis were performed at the implant-abutment joints. Results were statistically analyzed via one-way analysis of variance, with a significance level of P abutment surfaces. The minimum and maximum size of microgaps ranged from 0.5 μm up to 5.6 μm. Furthermore, defects were detected throughout the implant-abutment joint that can, ultimately, affect the microgap size after connection. Nanoindentation tests revealed a higher hardness (4.2 ± 0.4 GPa) for abutment composed of Ti6Al4V alloy when compared to implant composed of commercially pure Grade 4 titanium (3.2 ± 0.4 GPa). Surface defects produced during the machining of both implants and abutments can increase the size of microgaps and promote a misfit of implant-abutment joints. In addition, the mismatch in mechanical properties between abutment and implant can promote the wear of surfaces, affecting the size of microgaps and consequently the performance of the joints during mastication.

  16. Fully Implantable Deep Brain Stimulation System with Wireless Power Transmission for Long-term Use in Rodent Models of Parkinson's Disease.

    Science.gov (United States)

    Heo, Man Seung; Moon, Hyun Seok; Kim, Hee Chan; Park, Hyung Woo; Lim, Young Hoon; Paek, Sun Ha

    2015-03-01

    The purpose of this study to develop new deep-brain stimulation system for long-term use in animals, in order to develop a variety of neural prostheses. Our system has two distinguished features, which are the fully implanted system having wearable wireless power transfer and ability to change the parameter of stimulus parameter. It is useful for obtaining a variety of data from a long-term experiment. To validate our system, we performed pre-clinical test in Parkinson's disease-rat models for 4 weeks. Through the in vivo test, we observed the possibility of not only long-term implantation and stability, but also free movement of animals. We confirmed that the electrical stimulation neither caused any side effect nor damaged the electrodes. We proved possibility of our system to conduct the long-term pre-clinical test in variety of parameter, which is available for development of neural prostheses.

  17. Twelve-month discontinuation rates of levonorgestrel intrauterine system 13.5 mg and subdermal etonogestrel implant in women aged 18-44: A retrospective claims database analysis.

    Science.gov (United States)

    Law, Amy; Liao, Laura; Lin, Jay; Yaldo, Avin; Lynen, Richard

    2018-04-21

    To investigate the 12-month discontinuation rates of levonorgestrel intrauterine system 13.5 mg (LNG-IUS 13.5) and subdermal etonogestrel (ENG) implant in the US. We identified women aged 18-44 who had an insertion of LNG-IUS 13.5 or ENG implant from the MarketScan Commercial claims database (7/1/2013-9/30/2014). Women were required to have 12 months of continuous insurance coverage prior to the insertion (baseline) and at least 12-months after (follow-up). Discontinuation was defined as presence of an insurance claim for pregnancy-related services, hysterectomy, female sterilization, a claim for another contraceptive method, or removal of the index contraceptive without re-insertion within 30 days. Using Cox regression we examined the potential impact of ENG implant vs. LNG-IUS 13.5 on the likelihood for discontinuation after controlling for patient characteristics. A total of 3680 (mean age: 25.4 years) LNG-IUS 13.5 and 23,770 (mean age: 24.6 years) ENG implant users met the selection criteria. Prior to insertion, 56.6% of LNG-IUS 13.5 and 42.1% of ENG implant users had used contraceptives, with oral contraceptives being most common (LNG-IUS 13.5: 42.1%; ENG implant: 28.5%). Among users of LNG-IUS 13.5 and ENG implant, rates of discontinuation were similar during the 12-month follow-up (LNG-IUS 13.5: 24.9%; ENG implant: 24.0%). Regression results showed that women using LNG-IUS 13.5 vs. ENG implant had similar likelihood for discontinuation (hazard ratio: 0.97, 95% confidence interval: 0.90-1.05, p=.41). In the real-world US setting, women aged 18-44 using LNG-IUS 13.5 and ENG implant have similar discontinuation rates after 12 months. In the United States, women aged 18-44 using levonorgestrel intrauterine system (13.5 mg) and subdermal etonogestrel implant have similar discontinuation rates after 12 months. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Immediate loading with single-piece implant following extraction

    Directory of Open Access Journals (Sweden)

    Hemlata Dwivedi

    2017-01-01

    Full Text Available Although dental implantology had evolved over a number of years, many dental surgeons are unaware of the concept of immediate loading with the use of one-piece implant that began in the early 1960s. The goal of successful prosthodontics rehabilitation is to provide function, esthetics, and comfort to the patient. The aim of this literature is to provide an overview of one-piece implant, with its advantages and disadvantages over conventional two-piece implant. Immediate prosthetic of a one-piece system allows for a better tissue healing and better adhesion of gingival mucosa to form a collar which is healthy and adherent to the implant, avoiding a second surgical procedure, and also includes a very important aspect esthetics. This article describes a case report of immediate loading with single-piece implant following extraction.

  19. Implantation of β-emitters on biomedical implants: 32 P isotropic ion implantation using a coaxial plasma reactor

    International Nuclear Information System (INIS)

    Fortin, M.A.; Paynter, R.W.; Sarkissian, A.; Stansfield, B.L.; Terreault, B.; Dufresne, V.

    2003-01-01

    The development of endovascular brachytherapy and the treatment of certain types of cancers (liver, lung, prostate) often require the use of beta-emitters, sometimes in the form of radioisotope-implanted devices. Among the most commonly used isotopes figures 32 P, a pure beta-emitter (maximum energy: 1.7 MeV), of which the path in biological tissues is of a few cm, restricting the impact of electron bombardment to the immediate environment of the implant. Several techniques and processes have been tried to elaborate surfaces and devices showing strongly bonded, or implanted 32 P. Anodizing, vapor phase deposition, grafting of oligonucleotides, as well as ion implantation processes have been investigated by several research groups as methods to implant beta-radioisotopes into surfaces. A coaxial plasma reactor was developed at INRS to implant radioisotopes into cylindrical metallic objects, such as coronary stents commonly used in angioplasty procedures. The dispersion of 32 P atoms on the interior surfaces of the chamber can be investigated using radiographs, contributing to image the plasma ion transport mechanisms that guide the efficiency of the implantation procedure. The amount of radioactivity on the wall liner, on the internal components, and on the biomedical implants are quantified using a surface barrier detector. A comparative study establishes a relationship between the gray scale of the radiographs, and dose measurements. A program was developed to convert the digitized images into maps showing surface dose density in mCi/cm 2 . An integration process allows the quantification of the doses on the walls and components of the reactor. Finally, the resulting integral of the 32 P dose is correlated to the initial amount of radioactivity inserted inside the implanter before the dismantling procedure. This method could be introduced as a fast and reliable way to test, qualify and assess the amount of radioactivity present on the as-produced implants

  20. Tribology of implantation bilayers

    International Nuclear Information System (INIS)

    Pivin, J.C.

    1989-01-01

    The mechanical behaviour of implantation films must be analysed in terms of bilayer rheology (laws of mechanical behaviour). Tribology takes into account thermodynamical, chemical and metallurgical parameters to interpret the friction properties of a system as a whole. One can distinguish between alloying effects of ion implantation and structural modifications. Alloying affects the basic properties of the crystal: elasticity, cohesion, mobility of planar defects, and its surface electronic structure, which determines the reactivity with the atmosphere or the friction counterpart (adhesion). Radiation damage and phase changes act more particularly on the modes of gliding and climbing of dislocations, and fracture mechanisms. 105 refs.; 11 figs.; 1 table

  1. Dental implants in medically complex patients-a retrospective study.

    Science.gov (United States)

    Manor, Yifat; Simon, Roy; Haim, Doron; Garfunkel, Adi; Moses, Ofer

    2017-03-01

    Dental implant insertion for oral rehabilitation is a worldwide procedure for healthy and medically compromised patients. The impact of systemic disease risks on the outcome of implant therapy is unclear, since there are few if any published randomized controlled trials (RCTs). The objective of this study is to investigate the rate of complications and failures following dental implantation in medically compromised patients in order to elucidate risk factors and prevent them. A retrospective cohort study was conducted from patient files treated with dental implantation between the years 2008-2014. The study group consisted of medically complex patients while the control group consisted of healthy patients. Preoperative, intraoperative, and post operative clinical details were retrieved from patients' files. The survival rate and the success rate of the dental implants were evaluated clinically and radiographically. A total of 204 patients (1003 dental implants) were included in the research, in the study group, 93 patients with 528 dental implants and in the control group, 111 patients with 475 dental implants. No significant differences were found between the groups regarding implant failures or complications. The failure rate of dental implants among the patients was 11.8 % in the study group and 16.2 % in the control group (P = 0.04). It was found that patients with a higher number of implants (mean 6.8) had failures compared with patients with a lower number of implants (mean 4.2) regardless of their health status (P dental implantation in medically complex patients and in healthy patients. Medically complex patients can undergo dental implantation. There are similar rates of complications and failures of dental implants in medically complex patients and in healthy patients.

  2. Dose measurement of ion implanted silicon by RBS technique

    International Nuclear Information System (INIS)

    Kamawanna, Teerasak; Intarasiri, Saweat; Prapunsri, Chowunchun; Thongleurm, Chome; Maleepatra, Saenee; Singkarat, Somsorn

    2003-10-01

    Surface modification can be achieved by ion implantation. This study used a 1 mm thick silicon wafer as a target which was implanted with Ar+ at 80 keV. The degree of the modification depends on both the ion energy and the implanted dose. The distribution of argon in the silicon substrate and the absolute implanted dose can be measured by using Rutherford Backscattering Spectrometry (RBS). These investigations utilized a 1.7 MV Tandetron accelerator system at Chiang Mai University. The dose determination by a direct calculation is in agreement with the simulation by the SIMNRA code

  3. Amorphous surface layers in Ti-implanted Fe

    International Nuclear Information System (INIS)

    Knapp, J.A.; Follstaedt, D.M.; Picraux, S.T.

    1979-01-01

    Implanting Ti into high-purity Fe results in an amorphous surface layer which is composed of not only Fe and Ti, but also C. Implantations were carried out at room temperature over the energy range 90 to 190 keV and fluence range 1 to 2 x 10 16 at/cm 2 . The Ti-implanted Fe system has been characterized using transmission electron microscopy (TEM), ion backscattering and channeling analysis, and (d,p) nuclear reaction analysis. The amorphous layer was observed to form at the surface and grow inward with increasing Ti fluence. For an implant of 1 x 10 17 Ti/cm 2 at 180 keV the layer thickness was 150 A, while the measured range of the implanted Ti was approx. 550 A. This difference is due to the incorporation of C into the amorphous alloy by C being deposited on the surface during implantation and subsequently diffusing into the solid. Our results indicate that C is an essential constituent of the amorphous phase for Ti concentrations less than or equal to 10 at. %. For the 1 x 10 17 Ti/cm 2 implant, the concentration of C in the amorphous phase was approx. 25 at. %, while that of Ti was only approx. 3 at. %. A higher fluence implant of 2 x 10 17 Ti/cm 2 produced an amorphous layer with a lower C concentration of approx. 10 at. % and a Ti concentration of approx. 20 at. %

  4. [Clinical Trial to Test the iFuse Implant System® in Patients with Sacroiliac Joint Syndrome: One Year Results].

    Science.gov (United States)

    Bornemann, R; Pflugmacher, R; Webler, M; Koch, E M W; Dengler, J; Wirtz, D C; Frey, S P

    2016-12-01

    Background: This study reports one year post-operative monitoring of the efficacy and safety of iFuse Implant System® in patients with sacroiliac joint syndrome. Material and Methods: After 6 months of inadequate conservative treatment, patients with properly proven ISG syndrome were selected for surgery. The iFuse implants had a triangular profile and coating of porous titanium plasma spray and were used in the minimally invasive procedures. The procedure was performed under general anaesthesia and fluoroscopic control. In each case, three implants were placed. Results: 24 patients (22 f; 92 %; 54.9 ± 14 years) participated in the study. The operations were performed in 11 patients (46 %) on the left and in 13 patients (54 %) on the right. The mean operative time was 42.4 minutes (95 % CI: 35.6-49.3). The reduction in pain intensity on the VAS scale was 58 ± 11 mm (68 ± 7 %). The Oswestry score showed a median decrease of 44 percentage points (57 %). After 12 months, 15 patients (63 %) reported that they were taking no more painkillers. Conclusion: The minimally invasive treatment of patients with sacroiliac joint syndrome using the iFuse Implant System leads to significant analgesic effects over the period of one year; it also contributes significantly to improving the functioning of the patient. Georg Thieme Verlag KG Stuttgart · New York.

  5. Early implant-associated osteomyelitis results in a peri-implanted bacterial reservoir

    DEFF Research Database (Denmark)

    Jensen, Louise Kruse; Koch, Janne; Aalbæk, Bent

    2017-01-01

    weight of Staphylococcus aureus or saline was inserted into the right tibial bone of 12 pigs. The animals were consecutively killed on day 2, 4 and 6 following implantation. Bone tissue around the implant was histologically evaluated. Identification of S. aureus was performed immunohistochemically...... on tissue section and with scanning electron microscopy and peptide nucleic acid in situ hybridization on implants. The distance of the peri-implanted pathological bone area (PIBA), measured perpendicular to the implant, was significantly larger in infected animals compared to controls (p = 0...

  6. Influence of different implant materials on the primary stability of orthodontic mini-implants

    OpenAIRE

    Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang

    2012-01-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...

  7. Bacterial microleakage at the abutment-implant interface, in vitro study.

    Science.gov (United States)

    Larrucea, Carlos; Conrado, Aparicio; Olivares, Denise; Padilla, Carlos; Barrera, Andrea; Lobos, Olga

    2018-02-15

    In implant rehabilitation, a microspace is created at the abutment-implant interface (AII). Previous research has shown that oral microbiome can proliferate in this microspace and affect periimplant tissues, causing inflammation in peri-implant tissues. Preventing microbial leakages through the AII is therefore an important goal in implantology. To determine the presence of marginal bacterial microleakage at the AII according to the torque applied to the prosthetic implant in vitro. Twenty-five Ticare Inhex internal conical implants (MG Mozo-Grau, Valladolid, España) were connected to a prosthetic abutment using torques of micro TC, while the rest were mounted on devices according to the bacterial leakage model with Porphyromonas gingivalis. Bacterial leakage was observed only in the implant adjustment as determined by micro-CT. The different torques applied to the abutment-implant system condition the bacterial leakage at the implant interface. No microleakage was observed at 20 and 30 N. © 2018 Wiley Periodicals, Inc.

  8. Clinical research in implant dentistry: evaluation of implant-supported restorations, aesthetic and patient-reported outcomes.

    Science.gov (United States)

    Lang, Niklaus P; Zitzmann, Nicola U

    2012-02-01

    The articles discussed in working group 3 dealt with specific aspects of clinical research. In this context, the literature reporting on survival and complication rates of implant-supported or implant-tooth supported restorations in longitudinal studies of at least 5 years were discussed. The second aspect dealt with the evaluation of aesthetic outcomes in clinical studies and the related index systems available. Finally, the third aspect discussed dealt with patient-reported outcome measures (PROMs). A detailed appraisal of the available methodology was presented. © 2012 John Wiley & Sons A/S.

  9. Emergency and elective implantation of covered stent systems in iatrogenic arterial injuries

    International Nuclear Information System (INIS)

    Goltz, J.P.; Kickuth, R.; Bastuerk, P.; Hoppe, H.; Triller, J.

    2011-01-01

    Purpose: To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury. Materials and Methods: Between 03/1998 and 12/2009, 31 patients underwent selective covered stent implantation after iatrogenic arterial injury. 12/31 of these patients (38.7 %) were hemodynamically unstable. Six different endovascular covered stent types were utilized. The primary endpoints of this study were technical and clinical success and rates of minor and major complications. Results: Initial angiograms demonstrated active extravasation in 19 (61.3 %) patients and pseudoaneurysms in 12 (38.7 %) patients. The following sites of bleeding origin were detected: axillary artery, subclavian artery, common iliac artery, external iliac artery, internal iliac artery, common femoral artery, superficial femoral artery, popliteal and fibular artery, femoro-popliteal and popliteo-crural bypasses, common hepatic artery, aberrant hepatic artery, cystic and gastroduodenal artery. In all patients bleeding was effectively controlled by covered stent implantation resulting in an immediate technical success of 100 %. Clinical success attributed to covered stent implantation was documented in 30 of the 31 patients (96.8 %). Major complications included death in four patients (11.1 %), acute thrombosis with arm ischemia in one patient (2.8 %) and stent fracture with associated pseudoaneurysm in another patient (2.8 %). In 2/31 patients (6.5 %) covered stent failure was detected and successfully treated by implantation of a second covered stent. Conclusion: Emergency and elective implantation of covered stents may be used for minimally invasive and effective management of iatrogenic arterial injury. (orig.)

  10. MEMS-Based Power Generation Techniques for Implantable Biosensing Applications

    Directory of Open Access Journals (Sweden)

    Jonathan Lueke

    2011-01-01

    Full Text Available Implantable biosensing is attractive for both medical monitoring and diagnostic applications. It is possible to monitor phenomena such as physical loads on joints or implants, vital signs, or osseointegration in vivo and in real time. Microelectromechanical (MEMS-based generation techniques can allow for the autonomous operation of implantable biosensors by generating electrical power to replace or supplement existing battery-based power systems. By supplementing existing battery-based power systems for implantable biosensors, the operational lifetime of the sensor is increased. In addition, the potential for a greater amount of available power allows additional components to be added to the biosensing module, such as computational and wireless and components, improving functionality and performance of the biosensor. Photovoltaic, thermovoltaic, micro fuel cell, electrostatic, electromagnetic, and piezoelectric based generation schemes are evaluated in this paper for applicability for implantable biosensing. MEMS-based generation techniques that harvest ambient energy, such as vibration, are much better suited for implantable biosensing applications than fuel-based approaches, producing up to milliwatts of electrical power. High power density MEMS-based approaches, such as piezoelectric and electromagnetic schemes, allow for supplemental and replacement power schemes for biosensing applications to improve device capabilities and performance. In addition, this may allow for the biosensor to be further miniaturized, reducing the need for relatively large batteries with respect to device size. This would cause the implanted biosensor to be less invasive, increasing the quality of care received by the patient.

  11. MEMS-based power generation techniques for implantable biosensing applications.

    Science.gov (United States)

    Lueke, Jonathan; Moussa, Walied A

    2011-01-01

    Implantable biosensing is attractive for both medical monitoring and diagnostic applications. It is possible to monitor phenomena such as physical loads on joints or implants, vital signs, or osseointegration in vivo and in real time. Microelectromechanical (MEMS)-based generation techniques can allow for the autonomous operation of implantable biosensors by generating electrical power to replace or supplement existing battery-based power systems. By supplementing existing battery-based power systems for implantable biosensors, the operational lifetime of the sensor is increased. In addition, the potential for a greater amount of available power allows additional components to be added to the biosensing module, such as computational and wireless and components, improving functionality and performance of the biosensor. Photovoltaic, thermovoltaic, micro fuel cell, electrostatic, electromagnetic, and piezoelectric based generation schemes are evaluated in this paper for applicability for implantable biosensing. MEMS-based generation techniques that harvest ambient energy, such as vibration, are much better suited for implantable biosensing applications than fuel-based approaches, producing up to milliwatts of electrical power. High power density MEMS-based approaches, such as piezoelectric and electromagnetic schemes, allow for supplemental and replacement power schemes for biosensing applications to improve device capabilities and performance. In addition, this may allow for the biosensor to be further miniaturized, reducing the need for relatively large batteries with respect to device size. This would cause the implanted biosensor to be less invasive, increasing the quality of care received by the patient.

  12. Influence of different implant materials on the primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Pan, Chin-Yun; Chou, Szu-Ting; Tseng, Yu-Chuan; Yang, Yi-Hsin; Wu, Chao-Yi; Lan, Ting-Hsun; Liu, Pao-Hsin; Chang, Hong-Po

    2012-12-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft(3) trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates(®) device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05). Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success. Copyright © 2012. Published by Elsevier B.V.

  13. Influence of different implant materials on the primary stability of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Chin-Yun Pan

    2012-12-01

    Full Text Available This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm. The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft3 trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates® device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05. Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success.

  14. Critical Assessment of Implantable Drug Delivery Devices in Glaucoma Management

    Directory of Open Access Journals (Sweden)

    Dharani Manickavasagam

    2013-01-01

    Full Text Available Glaucoma is a group of heterogeneous disorders involving progressive optic neuropathy that can culminate into visual impairment and irreversible blindness. Effective therapeutic interventions must address underlying vulnerability of retinal ganglion cells (RGCs to degeneration in conjunction with correcting other associated risk factors (such as elevated intraocular pressure. However, realization of therapeutic outcomes is heavily dependent on suitable delivery system that can overcome myriads of anatomical and physiological barriers to intraocular drug delivery. Development of clinically viable sustained release systems in glaucoma is a widely recognized unmet need. In this regard, implantable delivery systems may relieve the burden of chronic drug administration while potentially ensuring high intraocular drug bioavailability. Presently there are no FDA-approved implantable drug delivery devices for glaucoma even though there are several ongoing clinical studies. The paper critically assessed the prospects of polymeric implantable delivery systems in glaucoma while identifying factors that can dictate (a patient tolerability and acceptance, (b drug stability and drug release profiles, (c therapeutic efficacy, and (d toxicity and biocompatibility. The information gathered could be useful in future research and development efforts on implantable delivery systems in glaucoma.

  15. High current pelletron for ion implantation

    International Nuclear Information System (INIS)

    Schroeder, J.B.

    1989-01-01

    Since 1984, when the first production MeV ion implanter (an NEC model MV-T30) went on-line, interest in versatile electrostatic accelerator systems for MeV ion implantation has grown. The systems use a negative ion source to inject a tandem megavolt accelerator. In early systems the 0.4 mA of charging current from the two Pelletron charging chains in the accelerator was sufficient for the low intensity of beams from the ion source. This 2-chain system, however, is no longer adequate for the much higher beam intensities from today's improved ion sources. A 4-chain charging system, which delivers 1.3 mA to the high voltage terminal, was developed and is in operation in new models of NEC S Series Pelletron accelerators. This paper describes the latest beam performance of 1 MV and 1.7 MW Pelletron accelerators with this new 4-chain charging system. (orig.)

  16. Perceptions on hospitality when visiting secluded communities of guaranis, caiçaras e quilombolas in Paraty region

    Directory of Open Access Journals (Sweden)

    Luis Alberto Beares

    2008-10-01

    Full Text Available Tourism in secluded communities puts different cultures in contact with each other and must be handled carefully not to cause environmental damage as well as cultural loss which might jeopardize the local development and create hostile relationships. The proposal of in sito tourism, considering the local memory and patrimony as a hospitality potential, was observed during technical visitations to three communities located in the Paraty region and surroundings: Guarani, Caiçara (fishermen and Quilombola(African slaves descendants. Through field work involving visitations to communities and interviews with locals, information regarding cultural differences and the importance of the land occupation in the history of each of the communities was assessed. The common link in the history of these peoples is the struggle for the right of land possession. During visits when people shared their territory various forms of hospitality in each community were verified, issued from different cultures and cultural values.

  17. Heat generated by dental implant drills during osteotomy-a review: heat generated by dental implant drills.

    Science.gov (United States)

    Mishra, Sunil Kumar; Chowdhary, Ramesh

    2014-06-01

    Osseointegration is the more stable situation and results in a high success rate of dental implants. Heat generation during rotary cutting is one of the important factors influencing the development of osseointegration. To assess the various factors related to implant drills responsible for heat generation during osteotomy. To identify suitable literature, an electronic search was performed using Medline and Pubmed database. Articles published in between 1960 to February 2013 were searched. The search is focused on heat generated by dental implant drills during osteotomy. Various factors related to implant drill such effect of number of blades; drill design, drill fatigue, drill speed and force applied during osteotomies which were responsible for heat generation were reviewed. Titles and abstracts were screened, and literature that fulfilled the inclusion criteria was selected for a full-text reading. The initial literature search resulted in 299 articles out of which only 70 articles fulfils the inclusion criteria and were included in this systematic review. Many factors related to implant drill responsible for heat generation were found. Successful preparation of an implant cavity with minimal damage to the surrounding bone depends on the avoidance of excessive temperature generation during surgical drilling. The relationship between heat generated and implant drilling osteotomy is multifactorial in nature and its complexity has not been fully studied. Lack of scientific knowledge regarding this issue still exists. Further studies should be conducted to determine the various factors which generate less heat while osteotomy such as ideal ratio of force and speed in vivo, exact time to replace a drill, ideal drill design, irrigation system, drill-bone contact area.

  18. Imaging of common breast implants and implant-related complications: A pictorial essay

    OpenAIRE

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance i...

  19. Dual-modal photoacoustic and ultrasound imaging of dental implants

    Science.gov (United States)

    Lee, Donghyun; Park, Sungjo; Kim, Chulhong

    2018-02-01

    Dental implants are common method to replace decayed or broken tooth. As the implant treatment procedures varies according to the patients' jawbone, bone ridge, and sinus structure, appropriate examinations are necessary for successful treatment. Currently, radiographic examinations including periapical radiology, panoramic X-ray, and computed tomography are commonly used for diagnosing and monitoring. However, these radiographic examinations have limitations in that patients and operators are exposed to radioactivity and multiple examinations are performed during the treatment. In this study, we demonstrated photoacoustic (PA) and ultrasound (US) combined imaging of dental implant that can lower the total amount of absorbed radiation dose in dental implant treatment. An acoustic resolution PA macroscopy and a clinical PA/US system was used for dental implant imaging. The acquired dual modal PA/US imaging results support that the proposed photoacoustic imaging strategy can reduce the radiation dose rate during dental implant treatment.

  20. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  1. [Clinical application of individualized three-dimensional printing implant template in multi-tooth dental implantation].

    Science.gov (United States)

    Wang, Lie; Chen, Zhi-Yuan; Liu, Rong; Zeng, Hao

    2017-08-01

    To study the value and satisfaction of three-dimensional printing implant template and conventional implant template in multi-tooth dental implantation. Thirty cases (83 teeth) with missing teeth needing to be implanted were randomly divided into conventional implant template group (CIT group, 15 cases, 42 teeth) and 3D printing implant template group (TDPIT group, 15 cases, 41 teeth). Patients in CIT group were operated by using conventional implant template, while patients in TDPIT group were operated by using three-dimensional printing implant template. The differences of implant neck and tip deviation, implant angle deviation and angle satisfaction between the two groups were compared. The difference of probing depth and bone resorption of implant were compared 1 year after operation between the two groups. The difference of success rate and satisfaction of dental implantation were compared 1 year after operation between the two groups. SPSS19.0 software package was used for statistical analysis. The deviation direction of the neck and the tip in disto-mesial, bucco-palatal, vertical direction and angle of implants in disto-mesial and bucco-palatal direction in TDPIT group were significantly lower than in CIT group (P0.05). The difference of the cumulative success rate in dental implantation at 3 months and 6 months between the two groups were not significant (P>0.05), but the cumulative success rate of TDPIT group was significantly higher than CIT group at 9 months and 1 year (90.48% vs 100%,P=0.043). The patients' satisfaction rate of dental implantation in TDPIT group was significantly higher than in CIT group (86.67% vs 53.33%, P=0.046). Using three-dimensional printing implant template can obtain better accuracy of implant, higher implant success rate and better patients' satisfaction than using conventional implant template. It is suitable for clinical application.

  2. K.s. Micro-implant placement guide.

    Science.gov (United States)

    Sharma, K; Sangwan, A

    2014-09-01

    A one of the greatest concerns with orthodontic mini-implants is risk of injury to dental roots during placement is, especially when they are inserted between teeth. Many techniques have been used to facilitate safe placement of interradicular miniscrews. Brass Wires or metallic markers are easy to place in the interproximal spaces, but because their relative positions may be inconsistent in different radio -graphic views, they are not always accurate. K.S. micro implant placement guide suggested in this article is simple design and easy in fabrication, required minimal equipment for fabrication and does not disturb the existing appliance system, clearly located in the radiograph and the mini-screw can be easily inserted through the guide reducing the chance of implant misplacement.

  3. Implante con el sistema de reparación herniaria inguinal de prolene (Prolene hernia system

    Directory of Open Access Journals (Sweden)

    José Goderich Lalán

    2002-04-01

    Full Text Available Se realizó un estudio clinicodescriptivo y prospectivo del seguimiento de 21 pacientes a los que se les realizó implante sistema de reparación herniaria inguinal de prolene en hernias inguinales, reproducidas entre el 15 de octubre de 1998 y el 31 de marzo de 1999, con el objetivo de evaluar sus resultados. En todos los casos se utilizó el método de cirugía de corta estadía, anestesia local y sedación o espinal y antibioticoterapia profiláctica. En el seguimiento a muy corto plazo no se reportan recidivas y ninguna complicación posoperatoria. Más de la mitad de los pacientes había recibido más de 2 operaciones. La media de edad fue 49 años y el sexo predominante el masculino. La técnica que se utilizó para implante fue la recomendada por los fabricantesA clinical descriptive and prospective study of the follow-up of 21 patients who received implant of the Prolene inguinal hernia repair system in inguinal hernias reproduced between October l5th, 1998, and March 31st, 1999, was conducted aimed at evaluating the results. The short-stay surgery method, local anesthesia and sedation, or spinal anesthesia and prophylactic antibiotic therapy were used in all cases. No relapses or postoperative complications were reported in a very short-term follow-up. More than half of the patients had undergone more than 2 operations. Average age was 49 and there was a predominance of males. The technique used for the implant was the one recommended by the manufacturers

  4. A generic miniature multi-feature programmable wireless powering headstage ASIC for implantable biomedical systems.

    Science.gov (United States)

    Kubendran, Rajkumar; Krishnan, Harish; Manola, Bhupendra; John, Simon W M; Chappell, William J; Irazoqui, Pedro P

    2011-01-01

    Wireless powering holds immense promise to enable a variety of implantable biomedical measurement systems with different power supply and current budget requirements. Effective power management demands more functionality in the headstage design like power level detection for range estimation and power save modes for sleep-wake operation. This paper proposes a single chip ASIC solution that addresses these problems by incorporating digitally programmable features and thus has the potential to enable wireless powering for many implantable systems. The ASIC includes an RF rectifier which has a peak efficiency of 17.9% at 900 MHz and 11.0% at 2.4 GHz, a robust 1 V bandgap reference and LDO voltage regulator whose output can be programmed in the range of 1 V-1.5 V, and can drive upto 4 mA of load current. The input RF power level detector has a threshold of 1.6 V and the power management block can be programmed to give a 6%, 12.5% or 25% duty cycle power line to the transmitter resulting in upto 60% reduction in average power. The ASIC was fabricated using the TSMC 65 nm process, occupies 1mm(2) die area and the headstage consumes ~300 μA at 1.2V regulated supply.

  5. Implantation and use of a version of the GAMALTA computer code in the 3.500 M Lecroy system

    International Nuclear Information System (INIS)

    Auler, L.T.

    1984-05-01

    The GAMALTA computer code was implanted in the 3.500 M Le Croy system, for creating an optional analysis function which is charged in RAM memory from a discket. The mode to construct functions to make part of the menu of the system is explained and a procedure to use the GAMALTA code is done. (M.C.K.) [pt

  6. Longitudinal Vision-Related Quality of Life for Patients with Noninfectious Uveitis Treated with Fluocinolone Acetonide Implant or Systemic Corticosteroid Therapy.

    Science.gov (United States)

    Sugar, Elizabeth A; Venugopal, Vidya; Thorne, Jennifer E; Frick, Kevin D; Holland, Gary N; Wang, Robert C; Almanzor, Robert; Jabs, Douglas A; Holbrook, Janet T

    2017-11-01

    To evaluate longitudinal vision-related quality of life (VRQoL) in patients with noninfectious uveitis. Cohort study using randomized controlled trial data. Patients with active or recently active intermediate uveitis, posterior uveitis, or panuveitis enrolled in the Multicenter Steroid Treatment Trial and Follow-up Study. Data from the 25-item National Eye Institute Visual Functioning Questionnaire (NEI-VFQ-25) for the first 3 years after randomization were evaluated semiannually. Analyses were stratified by assigned treatment (129 implants vs. 126 systemic therapies) because of substantial differences in the trajectories of VRQoL. The impact of baseline measurements of visual function (visual acuity and visual field), demographics, and disease characteristics was assessed using generalized estimating equations. Primary outcome was the NEI-VFQ-25 composite score over 3 years after randomization. Individuals in both treatment groups showed similar improvement in NEI-VFQ-25 scores after 3 years of follow-up (implant: 11.9 points; 95% confidence interval [CI], 8.6-15.2; P treatment groups. In the systemic group, these differences were maintained throughout follow-up. In the implant group, individuals with initial visual acuity worse than 20/40 showed additional improvement in NEI-VFQ-25 score to come within -7 points (95% CI, -15.0 to 0.9) of those with visual acuity 20/40 or better initially, a clinically meaningful but not statistically significant difference (P = 0.081). Results based on sensitivity analyses showed similar patterns. Both treatment groups demonstrated significant improvements in NEI-VFQ-25 scores; however, the improvement was immediate for the implant group as opposed to gradual for the systemic group. Poorer visual function was associated significantly with initial differences in NEI-VFQ-25 scores. However, only individuals in the implant group with poor visual acuity were able to overcome their initial deficits by the end of 3 years

  7. Influence of the ion implantation on the nanoscale intermetallic phases formation in Ni-Ti system

    International Nuclear Information System (INIS)

    Kalashnikov, M.P.; Kurzina, I.A.; Bozhko, I.A.; Kozlov, E.V.; Fortuna, S.V.; Sivin, D.O.; Stepanov, I.B.; Sharkeev, Yu.P.

    2005-01-01

    Full text: The ion implantation at a high intensity mode is an effective method for modification of the surface properties of metals and alloys. Improvement of mechanical and tribological properties of irradiated materials using the high intensity implantation is connected with an element composition and microstructure modification of the surface and subsurface layers. One shows a great interest in intermetallic phase's synthesis by ion implantation, because of unique physical-mechanical properties of the intermetallic compounds. The influence of the irradiation conditions on the structural state and surface properties of implanted materials is not clear enough. The study of the factors influencing on the formation of the surface ion - alloyed layers of metal targets having the high tribological and mechanical properties by high intensity ion implantation is actual. The aim of the present work is a study of the microstructure, phase composition, physical and mechanical properties of the ion-alloyed Ni surfaces formed at high intensity implantation of Ti ions. The implantation Ti ions into Ni samples at high intensity mode was realized using ion source 'Raduga - 5'. The implantation Ti ions into Ni was carried out at accelerating voltage 20 kV for 2 h. The regimes were differed in the samples temperature (580 - 700 K), the distance from the ion implanted samples to the ion source (0.43-0.93 m) and the dose of irradiated ions (0.3·10 18 -2.9·10 18 ion/cm -2 ). The element composition of the implanted samples was analyzed by the electron spectroscopy. The structural-phase state of the Ni ion-modified layers was investigated by the transmission electron microscopy and X-ray diffraction methods. Additionally, the investigation of mechanical and tribological properties of the implanted Ni samples was carried out. It was established that the maximum thickness of the ion-alloyed nickel layers at high intensity mode allows forming the nanoscale intermetallic phases (Ni

  8. Failure of Urological Implants in Spinal Cord Injury Patients due to Infection, Malfunction, and Implants Becoming Obsolete due to Medical Progress and Age-Related Changes in Human Body Making Implant Futile: Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2013-01-01

    Full Text Available Any new clinical data, whether positive or negative, generated about a medical device should be published because health professionals should know which devices do not work, as well as those which do. We report three spinal cord injury patients in whom urological implants failed to work. In the first, paraplegic, patient, a sacral anterior root stimulator failed to produce erection, and a drug delivery system for intracavernosal administration of vasoactive drugs was therefore implanted; however, this implant never functioned (and, furthermore, such penile drug delivery systems to produce erection had effectively become obsolete following the advent of phosphodiesterase type 5 inhibitors. Subsequently, the sacral anterior root stimulator developed a malfunction and the patient therefore learned to perform self-catheterisation. In the second patient, also paraplegic, an artificial urinary sphincter was implanted but the patient developed a postoperative sacral pressure sore. Eight months later, a suprapubic cystostomy was performed as urethral catheterisation was very difficult. The pressure sore had not healed completely even after five years. In the third case, a sacral anterior root stimulator was implanted in a tetraplegic patient in whom, after five years, a penile sheath could not be fitted because of penile retraction. This patient was therefore established on urethral catheter drainage. Later, infection with Staphylococcus aureus around the receiver block necessitated its removal. In conclusion, spinal cord injury patients are at risk of developing pressure sores, wound infections, malfunction of implants, and the inability to use implants because of age-related changes, as well as running the risk of their implants becoming obsolete due to advances in medicine. Some surgical procedures such as dorsal rhizotomy are irreversible. Alternative treatments such as intermittent catheterisations may be less damaging than bladder stimulator in

  9. Stable fixation of an osseointegated implant system for above-the-knee amputees: titel RSA and radiographic evaluation of migration and bone remodeling in 55 cases.

    Science.gov (United States)

    Nebergall, Audrey; Bragdon, Charles; Antonellis, Anne; Kärrholm, Johan; Brånemark, Rickard; Malchau, Henrik

    2012-04-01

    Rehabilitation of patients with transfemoral amputations is particularly difficult due to problems in using standard socket prostheses. We wanted to assess long-term fixation of the osseointegrated implant system (OPRA) using radiostereometric analysis (RSA) and periprosthetic bone remodeling. 51 patients with transfemoral amputations (55 implants) were enrolled in an RSA study. RSA and plain radiographs were scheduled at 6 months and at 1, 2, 5, 7, and 10 years after surgery. RSA films were analyzed using UmRSA software. Plain radiographs were graded for bone resorption, cancellization, cortical thinning, and trabecular streaming or buttressing in specifically defined zones around the implant. At 5 years, the median (SE) migration of the implant was -0.02 (0.06) mm distally. The rotational movement was 0.42 (0.32) degrees around the longitudinal axis. There was no statistically significant difference in median rotation or migration at any follow-up time. Cancellization of the cortex (plain radiographic grading) appeared in at least 1 zone in over half of the patients at 2 years. However, the prevalence of cancellization had decreased by the 5-year follow-up. The RSA analysis for the OPRA system indicated stable fixation of the implant. The periprosthetic bone remodeling showed similarities with changes seen around uncemented hip stems. The OPRA system is a new and promising approach for addressing the challenges faced by patients with transfemoral amputations.

  10. A comparative evaluation of linear dimensional accuracy of the dies obtained using three conceptually different die systems in the fabrication of implant prosthesis: An in vitro study

    Directory of Open Access Journals (Sweden)

    Manawar Ahmad

    2014-01-01

    Purpose: The purpose of the study was to evaluate the linear dimensional accuracy between the implant master die and three conceptually different die systems such as Pindex system, Accu-trac precision die system, and Conventional brass dowel pin system. Materials and Methods: Thirty impressions of implant master die were made with polyether impression material. Ten experimental implant casts were fabricated for each of the three different die systems tested: Accu-trac precision die tray system, Pindex system, and conventional brass dowel pin system. The solid experimental casts were sectioned and then removed from the die system 30 times. Linear distances between all six possible distances were measured from one centre of the transfer coping to the other, using a co-ordinate measuring machine in millimeters up to accuracy of 0.5 microns. Data were tabulated and statistically analyzed by Binomial non parametric test using SPSS version 15. Results: Significant differences were found for distance A-B (P = 0.002, A-C ( P = 0.002, A-D (P value = 0.002, and B-D ( P = 0.021 in Conventional Dowel pin system however for Accu-trac precision die tray system, it was significant only for distance A-D (P = 0.002 but for Pindex system it was non-significant for all the distances measured. Conclusion: Within the limitations of this study, use of Pindex system is recommended when sectioned dies are needed for a multi implant retained prosthesis.

  11. Influence of controlled immediate loading and implant design on peri-implant bone formation.

    Science.gov (United States)

    Vandamme, Katleen; Naert, Ignace; Geris, Liesbet; Vander Sloten, Jozef; Puers, Robert; Duyck, Joke

    2007-02-01

    Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. A significantly higher bone area fraction was observed for SL compared with SU (pimplant contact occurred was the highest for SL and significantly different from SU (pimplant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.

  12. Implantation of Martian Materials in the Inner Solar System by a Mega Impact on Mars

    Science.gov (United States)

    Hyodo, Ryuki; Genda, Hidenori

    2018-04-01

    Observations and meteorites indicate that the Martian materials are enigmatically distributed within the inner solar system. A mega impact on Mars creating a Martian hemispheric dichotomy and the Martian moons can potentially eject Martian materials. A recent work has shown that the mega-impact-induced debris is potentially captured as the Martian Trojans and implanted in the asteroid belt. However, the amount, distribution, and composition of the debris has not been studied. Here, using hydrodynamic simulations, we report that a large amount of debris (∼1% of Mars’ mass), including Martian crust/mantle and the impactor’s materials (∼20:80), are ejected by a dichotomy-forming impact, and distributed between ∼0.5–3.0 au. Our result indicates that unmelted Martian mantle debris (∼0.02% of Mars’ mass) can be the source of Martian Trojans, olivine-rich asteroids in the Hungarian region and the main asteroid belt, and some even hit the early Earth. The evidence of a mega impact on Mars would be recorded as a spike of 40Ar–39Ar ages in meteorites. A mega impact can naturally implant Martian mantle materials within the inner solar system.

  13. A Meta-Analysis of the Incidence of Patient-Reported Dysphagia After Anterior Cervical Decompression and Fusion with the Zero-Profile Implant System.

    Science.gov (United States)

    Yang, Yi; Ma, Litai; Liu, Hao; Xu, MangMang

    2016-04-01

    Dysphagia is a well-known complication following anterior cervical surgery. It has been reported that the Zero-profile Implant System can decrease the incidence of dysphagia following surgery, however, dysphagia after anterior cervical decompression and fusion (ACDF) with the Zero-profile Implant System remains controversial. Previous studies only focus on small sample sizes. The objective of this study was to determine the incidence of dysphagia after ACDF with the Zero-profile Implant System. Studies were collected from PubMed, EMBASE, the Cochrane library and the China Knowledge Resource Integrated Database using the keywords "Zero-profile OR Zero-p) AND (dysphagia OR [swallowing dysfunction]". The software STATA (Version 13.0) was used for statistical analysis. Statistical heterogeneity across the various trials, a test of publication bias and sensitivity analysis was performed. 30 studies with a total of 1062 patients were included in this meta-analysis. The occurrence of post-operative transient dysphagia ranged from 0 to 76 % whilst the pooled incidence was 15.6 % (95 % CI, 12.6, 18.5 %). 23 studies reported no persistent dysphagia whilst seven studies reported persistent dysphagia ranging from 1 to 7 %). In summary, the present study observed a low incidence of both transient and persistent dysphagia after ACDF using the Zero-profile Implant System. Most of the dysphagia was mild and gradually decreased during the following months. Moderate or severe dysphagia was uncommon. Future randomized controlled multi-center studies and those focusing on the mechanisms of dysphagia and methods to reduce its incidence are required.

  14. Biocompatibility and Systemic Safety of a Novel Implantable Annuloplasty Ring for the Treatment of Mitral Regurgitation in a Minipig Model.

    Science.gov (United States)

    Ramot, Yuval; Rousselle, Serge D; Yellin, Nadav; Willenz, Udi; Sabag, Itai; Avner, Avi; Nyska, Abraham

    2016-07-01

    Prosthetic annuloplasty rings are a common treatment modality for mitral regurgitation, and recently, percutaneous implantation techniques have gained popularity due to their favorable safety profile. Although in common use, biocompatibility of annuloplasty rings has been reported only sparsely in the literature, and none of these reports used the percutaneous technique of implantation. We report on the biocompatibility and the systemic safety of a novel transcatheter mitral valve annuloplasty ring (AMEND™) in 6 minipigs. This device is composed of a nitinol tube surrounded by a braided polyethylene terephthalate fabric tube. The device produced no adverse inflammatory response, showing gradual integration between the metal ring and the fabric by normal host fibrocellular response, leading to complete neoendocardium coverage. There was no evidence for adverse reactions, rejection, or intolerance in the valvular structure. In 2 animals, hemopericardium resulted from the implantation procedure, leading to right-sided cardiac insufficiency with pulmonary edema and liver congestion. The findings reported herein can serve as a case study for the expected healing pathology reactions after implantation of transcatheter mitral valve annuloplasty rings. © The Author(s) 2016.

  15. Development of high impedance measurement system for water leakage detection in implantable neuroprosthetic devices.

    Science.gov (United States)

    Yousif, Aziz; Kelly, Shawn K

    2016-08-01

    There has been a push for a greater number of channels in implantable neuroprosthetic devices; but, that number has largely been limited by current hermetic packaging technology. Microfabricated packaging is becoming reality, but a standard testing system is needed to prepare these devices for clinical trials. Impedance measurements of electrodes built into the packaging layers may give an early warning of device failure and predict device lifetime. Because the impedance magnitudes of such devices can be on the order of gigaohms, a versatile system was designed to accommodate ultra-high impedances and allow future integrated circuit implementation in current neural prosthetic technologies. Here we present the circuitry, control software, and preliminary testing results of our designed system.

  16. Identifying patients with less potential to benefit from implantable cardioverter-defibrillator therapy: comparison of the performance of four risk scoring systems.

    Science.gov (United States)

    Kaura, Amit; Sunderland, Nicholas; Kamdar, Ravi; Petzer, Edward; McDonagh, Theresa; Murgatroyd, Francis; Dhillon, Para; Scott, Paul

    2017-08-01

    Patients at high non-sudden cardiac death risk may gain no significant benefit from implantable cardioverter-defibrillator (ICD) therapy. A number of approaches have been proposed to identify these patients, including single clinical markers and more complex scoring systems. The aims of this study were to use the proposed scoring systems to (1) establish how many current ICD recipients may be too high risk to derive significant benefit from ICD therapy and (2) evaluate how well the scoring systems predict short-term mortality in an unselected ICD cohort. We performed a single-centre retrospective observational study of all new ICD implants over 5 years (2009-2013). We used four published scoring systems (Bilchick, Goldenberg, Kramer and Parkash) and serum urea to identify new ICD recipients whose short-term predicted mortality risk was high. We evaluated how well the scoring systems predicted death. Over 5 years, there were 406 new implants (79% male, mean age 70 (60-76), 58% primary prevention). During a follow-up of 936 ± 560 days, 96 patients died. Using the scoring systems, the proportion of ICD recipients predicted to be at high short-term mortality risk were 5.9% (Bilchick), 34.7% (Goldenberg), 7.4% (Kramer), 21.4% (Parkash) and 25% (urea, cut-off of >9.28 mM). All four risk scores predicted mortality (P systems, a significant proportion of current ICD recipients are at high short-term mortality risk. Although all four scoring systems predicted mortality during follow-up, none significantly outperformed serum urea.

  17. Costs involved in using a cochlear implant in South Africa

    Directory of Open Access Journals (Sweden)

    Gillian Robyn Kerr

    2012-12-01

    Full Text Available Cochlear implantation is an expensive but effective lifelong intervention for individuals with a severe-to-profound hearing loss. The primary aim of this study was to survey the short- and long-term costs of cochlear implantation. Individuals (N=154 using cochlear implants obtained from the University of Stellenbosch-Tygerberg Hospital Cochlear Implant Unit in Cape Town, South Africa were surveyed using a questionnaire and patient record review. The questionnaire used a combination of closed and open-ended questions to gather both quantitative and qualitative information. Costs were categorised as short- and long-term costs. All costs were converted to constant rands (June 2010 using the Consumer Price Index to allow for comparison in real terms over time. In the first 10 years of implantation the average estimated costs incurred by adults totalled R379 626, and by children R455 225. The initial purchase of the implant system was the most substantial cost, followed by upgrading of the processor. Travel and accommodation costs peaked in the first 2 years. On average the participants spent R2 550 per year on batteries and spares. Rehabilitation for children cost an average of R7 200. Insurance costs averaged R4 040 per year, and processor repairs R3 000 each. In addition to the upfront expense of obtaining the cochlear implant system, individuals using a cochlear implant in South Africa should be prepared for the long-term costs of maintenance, accessing the unit, support services and additional costs associated with use. Knowledge of these costs is important to ensure that individuals are successful users of their cochlear implants in the long term.

  18. Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment

    OpenAIRE

    de Jesus Tavarez, Rudys Rodolfo; Bonachela, Wellington Cardoso; Xible, Anuar Antônio

    2011-01-01

    OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricate...

  19. Permanent Seed Implant Dosimetry (PSID)TM 4.5 version as isodose and Treatment Planning System (TPS) programme for brachytherapy

    International Nuclear Information System (INIS)

    Indra Saptiama; Moch Subechi; Anung Pujiyanto; Hotman Lubis; Herlan Setiawan

    2014-01-01

    The medical treatment using radiation therapy for cancer diseases is increasingly developed. One of the method used in radiotherapy is brachytherapy. Brachytherapy is radiation therapy method in which a radiation source is implanted in cancer cell directly so the dose accepted by cancer cell is the highest dose and the dose accepted by normal cell is the lowest dose. I-125 Seed have been made successfully in domestic. To support the implant of I-125 seed for brachytherapy needs computer programme for the isodose calculation and Treatment Planning System (TPS). Permanent Seed Implant Dosimetry (PSID) 4.5 is one of the isodose calculation and Treatment Planning System (TPS) programme that is owned by Center for Radioisotope and Radiopharmaceutical-BATAN. In isodose calculation, PSID 4.5 uses 1D formalism and 2D formalism based on AAPM-TG43 (Association of American Physicist in Medicine- Task Group No.43). Anisotropic function on 1D formalism depend on distance function while on 2D formalism count on distance and angle function therefore 2D formalism has isodose calculation better than 1D formalism usage. PSID 4.5 can display the isodose contour of the seed I-125 radiation source in 2 dimension (2D) and 3 dimension (3D). The computer programme of isodose calculation and TPS uses PSID 4.5 is expected able to help planning for seed I-125 implantation process for brachytherapy that used by paramedics and to support the usage of seed I-125 as domestic product. (author)

  20. Implant healing in experimental animal models of diabetes.

    Science.gov (United States)

    Le, Nga N; Rose, Michael B; Levinson, Howard; Klitzman, Bruce

    2011-05-01

    Diabetes mellitus is becoming increasingly prevalent worldwide. Additionally, there is an increasing number of patients receiving implantable devices such as glucose sensors and orthopedic implants. Thus, it is likely that the number of diabetic patients receiving these devices will also increase. Even though implantable medical devices are considered biocompatible by the Food and Drug Administration, the adverse tissue healing that occurs adjacent to these foreign objects is a leading cause of their failure. This foreign body response leads to fibrosis, encapsulation of the device, and a reduction or cessation of device performance. A second adverse event is microbial infection of implanted devices, which can lead to persistent local and systemic infections and also exacerbates the fibrotic response. Nearly half of all nosocomial infections are associated with the presence of an indwelling medical device. Events associated with both the foreign body response and implant infection can necessitate device removal and may lead to amputation, which is associated with significant morbidity and cost. Diabetes mellitus is generally indicated as a risk factor for the infection of a variety of implants such as prosthetic joints, pacemakers, implantable cardioverter defibrillators, penile implants, and urinary catheters. Implant infection rates in diabetic patients vary depending upon the implant and the microorganism, however, for example, diabetes was found to be a significant variable associated with a nearly 7.2% infection rate for implantable cardioverter defibrillators by the microorganism Candida albicans. While research has elucidated many of the altered mechanisms of diabetic cutaneous wound healing, the internal healing adjacent to indwelling medical devices in a diabetic model has rarely been studied. Understanding this healing process is crucial to facilitating improved device design. The purpose of this article is to summarize the physiologic factors that

  1. A conceptual knowledge-link model for supporting dental implant process

    OpenAIRE

    Szejka , Anderson Luis; Canciglieri , Osiris ,; Rudek , Marcelo; Panetto , Hervé

    2014-01-01

    International audience; Computer aided techniques widely used as diagnostic and surgical procedures tools are scarcely applied in implantology, which continues using visualization of CT images to define the parameters for dental implant process leaving to the dentist discretion the implant determination, since only the images analysis is non-deterministic. Thus, this research proposes the development of a knowledge-link model integrated to a reasoner system to support dental implant process t...

  2. Identification of the critical level of implantation of an osseointegrated prosthesis for above-knee amputees.

    Science.gov (United States)

    Andrango Castro, Elder Michael; Konvickova, Svatava; Daniel, Matej; Horak, Zdenek

    2017-11-01

    The aim of our study was to identify potential critical levels of implantation of an osseointegrated prosthesis for above-knee amputees. The implant used was the OPRA system. It was inserted in the femur at four different amputation heights, characterized by their residual limb ratios (0.299, 0.44, 0.58 and 0.73). The stress and strain distribution was evaluated in the bone-implant system during walking, considering a body mass of 100 kg. Considerably high stimulus (11,489 με) in the tissue near the tip was found at the highest implantation level. All models presented small non-physiologic stress values in the tissue around the implant. The results revealed that the implantation level has a decisive effect on bone-implant performance. Mainly, the analysis indicates adverse biomechanical conditions for implantations in very short residual limbs.

  3. Integration of implant planning workflows into the PACS infrastructure

    Science.gov (United States)

    Gessat, Michael; Strauß, Gero; Burgert, Oliver

    2008-03-01

    The integration of imaging devices, diagnostic workstations, and image servers into Picture Archiving and Communication Systems (PACS) has had an enormous effect on the efficiency of radiology workflows. The standardization of the information exchange between the devices with the DICOM standard has been an essential precondition for that development. For surgical procedures, no such infrastructure exists. With the increasingly important role computerized planning and assistance systems play in the surgical domain, an infrastructure that unifies the communication between devices becomes necessary. In recent publications, the need for a modularized system design has been established. A reference architecture for a Therapy Imaging and Model Management System (TIMMS) has been proposed. It was accepted by the DICOM Working Group 6 as the reference architecture for DICOM developments for surgery. In this paper we propose the inclusion of implant planning systems into the PACS infrastructure. We propose a generic information model for the patient specific selection and positioning of implants from a repository according to patient image data. The information models are based on clinical workflows from ENT, cardiac, and orthopedic surgery as well as technical requirements derived from different use cases and systems. We show an exemplary implementation of the model for application in ENT surgery: the selection and positioning of an ossicular implant in the middle ear. An implant repository is stored in the PACS. It makes use of an experimental implementation of the Surface Mesh Module that is currently being developed as extension to the DICOM standard.

  4. Defect-impurity interactions in ion-implanted metals

    International Nuclear Information System (INIS)

    Turos, A.

    1986-01-01

    An overview of defect-impurity interactions in metals is presented. When point defects become mobile they migrate towards the sinks and on the way can be captured by impurity atoms forming stable associations so-called complexes. In some metallic systems complexes can also be formed athermally during ion implantation by trapping point defects already in the collision cascade. An association of a point defect with an impurity atom leads to its displacement from the lattice site. The structure and stability of complexes are strongly temperature dependent. With increasing temperature they dissociate or grow by multiple defect trapping. The appearance of freely migrating point defects at elevated temperatures, due to ion bombardment or thermal annealing, causes via coupling with defect fluxes, important impurity redistribution. Because of the sensitivity of many metal-in-metal implanted systems to radiation damage the understanding of this processes is essential for a proper interpretation of the lattice occupancy measurements and the optimization of implantation conditions. (author)

  5. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current ...

  6. Improvement of tribological properties by ion implantation

    International Nuclear Information System (INIS)

    Gerve, A.

    1993-01-01

    Many different measurements confirm that ion implantation changes the friction and wear behaviour, which are the most important properties of tribological systems. Unfortunately, these properties will not always be improved. In industrial application, very often different results of the effects of ion implantation into tools or machine components can be observed, even if the same materials are used. A very important reason for this is the different stresses on the tribological systems. The energy input caused by friction, which is a function of the stress and other parameters of the tribosystem, within a short time leads to the appearance of energy islands, which are statistically distributed over the surfaces. The density of energy within these tiny energy islands is very high. Results of these high energy densities is a mutation of the material's composition and structure within a very thin layer of less than 100 nm underneath the surface and wear. Ion implantation also changes the composition and structure of the bulk material close to the surface. Thus there is urgent need to understand tribo-induced mutations of ion-implanted materials and their influence on the tribological properties. For that reason surface analyses have to be carried out to determine the composition and structure of the materials and the mutation caused by friction and wear

  7. Restoration of orbicularis oculi muscle function in rabbits with peripheral facial paralysis via an implantable artificial facial nerve system.

    Science.gov (United States)

    Sun, Yajing; Jin, Cheng; Li, Keyong; Zhang, Qunfeng; Geng, Liang; Liu, Xundao; Zhang, Yi

    2017-12-01

    The purpose of the present study was to restore orbicularis oculi muscle function using the implantable artificial facial nerve system (IAFNS). The in vivo part of the IAFNS was implanted into 12 rabbits that were facially paralyzed on the right side of the face to restore the function of the orbicularis oculi muscle, which was indicated by closure of the paralyzed eye when the contralateral side was closed. Wireless communication links were established between the in vivo part (the processing chip and microelectrode) and the external part (System Controller program) of the system, which were used to set the working parameters and indicate the working state of the processing chip and microelectrode implanted in the body. A disturbance field strength test of the IAFNS processing chip was performed in a magnetic field dark room to test its electromagnetic radiation safety. Test distances investigated were 0, 1, 3 and 10 m, and levels of radiation intensity were evaluated in the horizontal and vertical planes. Anti-interference experiments were performed to test the stability of the processing chip under the interference of electromagnetic radiation. The fully implanted IAFNS was run for 5 h per day for 30 consecutive days to evaluate the accuracy and precision as well as the long-term stability and effectiveness of wireless communication. The stimulus intensity (range, 0-8 mA) was set every 3 days to confirm the minimum stimulation intensity which could indicate the movement of the paralyzed side was set. Effective stimulation rate was also tested by comparing the number of eye-close movements on both sides. The results of the present study indicated that the IAFNS could rebuild the reflex arc, inducing the experimental rabbits to close the eye of the paralyzed side. The System Controller program was able to reflect the in vivo part of the artificial facial nerve system in real-time and adjust the working pattern, stimulation intensity and frequency, range of wave

  8. Surface modification of multi-point cutting tools using ion implantation

    International Nuclear Information System (INIS)

    Sarwar, M.; Ahmed, W.; Ahmed, M.

    1995-01-01

    Ion-implantation has been used to treat multi-point cutting tools using a 'systems approach' in order to improve the performance of these tools in dynamic cutting conditions. The effects of energy, species and system pressure on life and performance of circular saws have been investigated. For both nitrogen and argon ion-implantation an improvement in cutting performance has been observed as compared to untreated edges. As the energy of the nitrogen ions is increased there is a gradual improvement in the performance of the cutting edge. Ion-implanted tools were compared to those coated with TiN and these results are also presented. (author) 5 figs

  9. “In vitro” Implantation Technique Based on 3D Printed Prosthetic Prototypes

    Science.gov (United States)

    Tarnita, D.; Boborelu, C.; Geonea, I.; Malciu, R.; Grigorie, L.; Tarnita, D. N.

    2018-06-01

    In this paper, Rapid Prototyping ZCorp 310 system, based on high-performance composite powder and on resin-high strength infiltration system and three-dimensional printing as a manufacturing method are used to obtain physical prototypes of orthopaedic implants and prototypes of complex functional prosthetic systems directly from the 3D CAD data. These prototypes are useful for in vitro experimental tests and measurements to optimize and obtain final physical prototypes. Using a new elbow prosthesis model prototype obtained by 3D printing, the surgical technique of implantation is established. Surgical implantation was performed on male corpse elbow joint.

  10. Two-stage dental implants inserted in a one-stage procedure : a prospective comparative clinical study

    NARCIS (Netherlands)

    Heijdenrijk, Kees

    2002-01-01

    The results of this study indicate that dental implants designed for a submerged implantation procedure can be used in a single-stage procedure and may be as predictable as one-stage implants. Although one-stage implant systems and two-stage.

  11. Orthodontic mechanics using mini-implant measured by FBG

    Science.gov (United States)

    Trannin, Pamela G.; Milczewski, Maura S.; de Oliveira, Walmir; Guariza Filho, Odilon; Lopes, Stephani C. P. S.; Kalinowski, Hypolito J.

    2015-07-01

    The magnitude of the force generated during orthodontic mechanics anchored in mini-implant in a maxilla model was analyzed. Data was collected during the insertion of the mini-implant and at the moment of applying forces to the structure of the maxilla and dentition. To obtain quantitative results, the Fibre Bragg Gratings (FBG) were inserted in an elastomeric material reproducing a maxilla model. It was observed levels of forces of approximately 3,78N next to the root of first premolar by the insertion of the mini-implant and different levels of the force to different orthodontic mechanics applied on the dental system.

  12. A 65nm CMOS low-power MedRadio-band integer-N cascaded phase-locked loop for implantable medical systems.

    Science.gov (United States)

    Wang, Yi-Xiao; Chen, Wei-Ming; Wu, Chung-Yu

    2014-01-01

    This paper presents a low-power MedRadio-band integer-N phase-locked Loop (PLL) system which is composed of two charge-pump PLLs cascade connected. The PLL provides the operation clock and local carrier signals for an implantable medical electronic system. In addition, to avoid the off-chip crystal oscillator, the 13.56 MHz Industrial, Scientific and Medical (ISM) band signal from the wireless power transmission system is adopted as the input reference signal for the PLL. Ring-based voltage controlled oscillators (VCOs) with current control units are adopted to reduce chip area and power dissipation. The proposed cascaded PLL system is designed and implemented in TSMC 65-nm CMOS technology. The measured jitter for 216.96 MHz signal is 12.23 ps and the phase noise is -65.9 dBc/Hz at 100 kHz frequency offset under 402.926 MHz carrier frequency. The measured power dissipations are 66 μW in the first PLL and 195 μW in the whole system under 1-V supply voltage. The chip area is 0.1088 mm(2) and no off-chip component is required which is suitable for the integration of the implantable medical electronic system.

  13. Prevalence of Peri-Implant Mucositis and Peri-Implantitis in Patients Treated with a Combination of Axial and Tilted Implants Supporting a Complete Fixed Denture

    Directory of Open Access Journals (Sweden)

    Nicolò Cavalli

    2015-01-01

    Full Text Available Objectives. The aim of this retrospective study was to assess the incidence and prevalence of peri-implant mucositis and peri-implantitis in patients with a fixed full-arch prosthesis supported by two axial and two tilted implants. Materials and Methods. Sixty-nine patients were included in the study. Each patient received a fixed full-arch prosthesis supported by two mesial axial and two distal tilted implants to rehabilitate the upper arch, the lower arch, or both. Three hundred thirty-six implants for 84 restorations were delivered. Patients were scheduled for follow-up visits every 6 months in the first 2 years and yearly after. At each follow-up visit peri-implant mucositis and peri-implantitis were diagnosed if present. Results. The overall follow-up range was from 12 to 130 months (mean 63,2 months. Three patients presented peri-implantitis. The prevalence of peri-implant mucositis ranged between 0 and 7,14% of patients (5,06% of implants while the prevalence of peri-implantitis varied from 0 to 4,55% of patients (3,81% of implants. Conclusions. The prevalence and incidence of peri-implant mucositis and peri-implantitis are lower than most of the studies in literature. Therefore this kind of rehabilitation could be considered a feasible option, on the condition of adopting a systematic hygienic protocol.

  14. OXYGEN ISOTOPIC COMPOSITIONS OF SOLAR CORUNDUM GRAINS

    International Nuclear Information System (INIS)

    Makide, Kentaro; Nagashima, Kazuhide; Huss, Gary R.; Krot, Alexander N.

    2009-01-01

    Oxygen is one of the major rock-forming elements in the solar system and the third most abundant element of the Sun. Oxygen isotopic composition of the Sun, however, is not known due to a poor resolution of astronomical spectroscopic measurements. Several Δ 17 O values have been proposed for the composition of the Sun based on (1) the oxygen isotopic measurements of the solar wind implanted into metallic particles in lunar soil ( 2 O 3 ) is thermodynamically the first condensate from a cooling gas of solar composition. Corundum-bearing CAIs, however, are exceptionally rare, suggesting either continuous reaction of the corundum condensates with a cooling nebular gas and their replacement by hibonite (CaAl 12 O 19 ) or their destruction by melting together with less refractory condensates during formation of igneous CAIs. In contrast to the corundum-bearing CAIs, isolated micrometer-sized corundum grains are common in the acid-resistant residues from unmetamorphosed chondrites. These grains could have avoided multistage reprocessing during CAI formation and, therefore, can potentially provide constraints on the initial oxygen isotopic composition of the solar nebula, and, hence, of the Sun. Here we report oxygen isotopic compositions of ∼60 micrometer-sized corundum grains in the acid-resistant residues from unequilibrated ordinary chondrites (Semarkona (LL3.0), Bishunpur (LL3.1), Roosevelt County 075 (H3.2)) and unmetamorphosed carbonaceous chondrites (Orgueil (CI1), Murray (CM2), and Alan Hills A77307 (CO3.0)) measured with a Cameca ims-1280 ion microprobe. All corundum grains, except two, are 16 O-rich (Δ 17 O = -22.7 per mille ± 8.5 per mille, 2σ), and compositionally similar to the mineralogically pristine CAIs from the CR carbonaceous chondrites (-23.3 per mille ± 1.9 per mille, 2σ), and solar wind returned by the Genesis spacecraft (-27 per mille ± 6 per mille, 2σ). One corundum grain is highly 17 O-enriched (δ 17 O ∼ +60 per mille, δ 18 O

  15. The medically compromised patient: Are dental implants a feasible option?

    Science.gov (United States)

    Vissink, A; Spijkervet, Fkl; Raghoebar, G M

    2018-03-01

    In healthy subjects, dental implants have evolved to be a common therapy to solve problems related to stability and retention of dentures as well as to replace failing teeth. Although dental implants are applied in medically compromised patients, it is often not well known whether this therapy is also feasible in these patients, whether the risk of implant failure and developing peri-implantitis is increased, and what specific preventive measures, if any, have to be taken when applying dental implants in these patients. Generally speaking, as was the conclusion by the leading review of Diz, Scully, and Sanz on placement of dental implants in medically compromised patients (J Dent, 41, 2013, 195), in a few disorders implant survival may be lower, and the risk of a compromised peri-implant health and its related complications be greater, but the degree of systemic disease control outweighs the nature of the disorder rather than the risk accompanying dental implant treatment. So, as dental implant treatment is accompanied by significant functional benefits and improved oral health-related quality of life, dental implant therapy is a feasible treatment in almost any medically compromised patient when the required preventive measures are taken and follow-up care is at a high level. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.

  16. Indicators of soil quality in the implantation of no-till system with winter crops.

    OpenAIRE

    NOGUEIRA, M. A.; TELLES, T. S.; FAGOTTI, D. dos S. L.; BRITO, O. R.; PRETE, C. E. C.; GUIMARÃES, M. de F.

    2014-01-01

    We assessed the effect of different winter crops on indicators of soil quality related to C and N cycling and C fractions in a Rhodic Kandiudult under no-till system at implantation, during two growing seasons, in Londrina PR Brazil. The experimental design was randomized blocks with split-plot in time arrangement, with four replications. The parcels were the winter crops: multicropping of cover crops with black oat (Avena strigosa), hairy vetch (Vicia villosa) and fodder radish (Raphanus sat...

  17. Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature.

    Science.gov (United States)

    Klein, Doron; Hadad, Eran; Wiser, Itay; Wolf, Omer; Itzhaki Shapira, Ortal; Fucks, Shir; Heller, Lior

    2018-01-01

    Silicone breast implants from the French manufacturer Poly Implants Prosthèse (PIP) were recalled from the European market after the French regulator has revealed the implants contain non-medical-grade silicone filler. In December 2011, following a large increase in reported rupture rate and a possible cancer risk, the French Ministry of Health recommended consideration of the PIP explantation, regardless of their condition. In 2012, the Israel Ministry of Health recommended to replace the implants only upon suspected implant rupture. The aims of this study were to characterize breast-augmented Israeli patients with PIP implants, compare their outcomes with those of breast-augmented patients with different implant types, and review the current PIP literature. Breast-augmented patients who underwent an elective breast implant exchange in Israel between January 2011 and January 2017 were included in the study. Data were collected from electronic and physical medical files. There were 73 breast-augmented female patients with 146 PIP breast implants included in this study. Average implant age was 6.7 ± 2.79 years. Mean implant size was 342.8 ± 52.9 mL. Fourteen women (19 implants [16%]) had a high-grade capsular contracture (Baker grade 3-4). During exchange, 28 implants were found to be ruptured (19.2%). Less than 10 years following breast augmentation, PIP implants demonstrated higher rupture rate compared with other implants. Our data are comparable to overall available rupture rate. Among patients with definitive rupture diagnosis, an elective implant removal should be recommended. In cases of undamaged implants, plastic surgeons should also seriously consider PIP implant explantation. When the patient does not desire to remove the implant, an annual physical examination and breast ultrasound are recommended, beginning a year after augmentation.

  18. Analysis of risk factors for cluster behavior of dental implant failures.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-08-01

    Some studies indicated that implant failures are commonly concentrated in few patients. To identify and analyze cluster behavior of dental implant failures among subjects of a retrospective study. This retrospective study included patients receiving at least three implants only. Patients presenting at least three implant failures were classified as presenting a cluster behavior. Univariate and multivariate logistic regression models and generalized estimating equations analysis evaluated the effect of explanatory variables on the cluster behavior. There were 1406 patients with three or more implants (8337 implants, 592 failures). Sixty-seven (4.77%) patients presented cluster behavior, with 56.8% of all implant failures. The intake of antidepressants and bruxism were identified as potential negative factors exerting a statistically significant influence on a cluster behavior at the patient-level. The negative factors at the implant-level were turned implants, short implants, poor bone quality, age of the patient, the intake of medicaments to reduce the acid gastric production, smoking, and bruxism. A cluster pattern among patients with implant failure is highly probable. Factors of interest as predictors for implant failures could be a number of systemic and local factors, although a direct causal relationship cannot be ascertained. © 2017 Wiley Periodicals, Inc.

  19. Ion implantation into diamond

    International Nuclear Information System (INIS)

    Sato, Susumu

    1994-01-01

    The graphitization and the change to amorphous state of diamond surface layer by ion implantation and its characteristics are reported. In the diamond surface, into which more than 10 16 ions/cm 2 was implanted, the diamond crystals are broken, and the structure changes to other carbon structure such as amorphous state or graphite. Accompanying this change of structure, the electric conductivity of the implanted layer shows two discontinuous values due to high resistance and low resistance. This control of structure can be done by the temperature of the base during the ion implantation into diamond. Also it is referred to that by the base temperature during implantation, the mutual change of the structure between amorphous state and graphite can be controlled. The change of the electric resistance and the optical characteristics by the ion implantation into diamond surface, the structural analysis by Raman spectroscopy, and the control of the structure of the implanted layer by the base temperature during implantation are reported. (K.I.)

  20. An implantable thermoresponsive drug delivery system based on Peltier device.

    Science.gov (United States)

    Yang, Rongbing; Gorelov, Alexander V; Aldabbagh, Fawaz; Carroll, William M; Rochev, Yury

    2013-04-15

    Locally dropping the temperature in vivo is the main obstacle to the clinical use of a thermoresponsive drug delivery system. In this paper, a Peltier electronic element is incorporated with a thermoresponsive thin film based drug delivery system to form a new drug delivery device which can regulate the release of rhodamine B in a water environment at 37 °C. Various current signals are used to control the temperature of the cold side of the Peltier device and the volume of water on top of the Peltier device affects the change in temperature. The pulsatile on-demand release profile of the model drug is obtained by turning the current signal on and off. The work has shown that the 2600 mAh power source is enough to power this device for 1.3 h. Furthermore, the excessive heat will not cause thermal damage in the body as it will be dissipated by the thermoregulation of the human body. Therefore, this simple novel device can be implanted and should work well in vivo. Copyright © 2013 Elsevier B.V. All rights reserved.