WorldWideScience

Sample records for imaging initial experience

  1. Gamma Imaging-Guided Minimally Invasive Breast Biopsy: Initial Clinical Experience.

    Science.gov (United States)

    Brem, Rachel F; Mehta, Anita K; Rapelyea, Jocelyn A; Akin, Esma A; Bazoberry, Adriana M; Velasco, Christel D

    2018-03-01

    The purpose of this study was to evaluate our initial experience with gamma imaging-guided vacuum-assisted breast biopsy in women with abnormal findings. A retrospective review of patients undergoing breast-specific gamma imaging (BSGI), also known as molecular breast imaging (MBI), between April 2011 and October 2015 found 117 nonpalpable mammographically and sonographically occult lesions for which gamma imaging-guided biopsies were recommended. Biopsy was performed with a 9-gauge vacuum-assisted device with subsequent placement of a titanium biopsy site marker. Medical records and pathologic findings were evaluated. Of the 117 biopsies recommended, 104 were successful and 13 were canceled. Of the 104 performed biopsies, 32 (30.8%) had abnormal pathologic findings. Of those 32 biopsies, nine (28.1%) found invasive cancers, six (18.8%) found ductal carcinoma in situ (DCIS), and 17 (53.1%) found high-risk lesions. Of the 17 high-risk lesions, there were three (17.6%) lobular carcinomas in situ, five (29.4%) atypical ductal hyperplasias, two (11.8%) atypical lobular hyperplasias, one (5.9%) flat epithelial atypia, and six (35.3%) papillomas. Two cases of atypical ductal hyperplasia were upgraded to DCIS at surgery. The overall cancer detection rate for gamma imaging-guided biopsy was 16.3%. In this study, gamma imaging-guided biopsy had a positive predictive value of total successful biopsies of 16.3% for cancer and 30.8% for cancer and high-risk lesions. Gamma imaging-guided biopsy is a viable approach to sampling BSGI-MBI-detected lesions without sonographic or mammographic correlate. Our results compare favorably to those reported for MRI-guided biopsy.

  2. MR imaging-guided percutaneous cryotherapy for lung tumors: initial experience.

    Science.gov (United States)

    Liu, Shangang; Ren, Ruimei; Liu, Ming; Lv, Yubo; Li, Bin; Li, Chengli

    2014-09-01

    To evaluate prospectively the initial clinical experience of magnetic resonance (MR) imaging-guided percutaneous cryotherapy of lung tumors. MR imaging-guided percutaneous cryotherapy was performed in 21 patients with biopsy-proven lung tumors (12 men, 9 women; age range, 39-79 y). Follow-up consisted of contrast-enhanced chest computed tomography (CT) scan performed at 3-month intervals to assess tumor control; CT scanning was carried out for 12 months or until death. Cryotherapy procedures were successfully completed in all 21 patients. Pneumothorax occurred in 7 (33.3%) of 21 patients. Chest tube placement was required in one (4.8%) case. Hemoptysis was exhibited by 11 (52.4%) patients, and pleural effusion occurred in 6 (28.6%) patients. Other complications were observed in 14 (66.7%) patients. The mean follow-up period was 10.5 months (range, 9-12 mo) in patients who died. At month 12 of follow-up, 7 (33.3%) patients had a complete response to therapy, and 10 (47.6%) patients showed a partial response. In addition, two patients had stable disease, and two patients developed progressive disease; one patient developed a tumor in the liver, and the other developed a tumor in the brain. The 1-year local control rate was 81%, and 1-year survival rate was 90.5%. MR imaging-guided percutaneous cryotherapy appears feasible, effective, and minimally invasive for lung tumors. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  3. NMR imaging of the brain: initial impressions

    International Nuclear Information System (INIS)

    Spencer, D.H.; Bydder, G.M.

    1983-01-01

    An NMR imaging system designed and built by Thorn-EMI Ltd was installed at Hammersmith Hospital in March 1981. In the first year of operation 180 patients and 40 volunteers have had cranial examinations and initial impressions bases on this experience are presented. Patients with a wide variety of neurological diseases have been studied to provide a basis for diagnostic interpretation, to define distinctive features, and to evaluate different types of scanning sequences. NMR imaging appears to be of considerable value in neurological diagnosis and has a number of advantages over CT. The detailed evaluation of NMR imaging will require much more work but the initial results are very promising

  4. Cardiac biplane strain imaging: initial in vivo experience

    Energy Technology Data Exchange (ETDEWEB)

    Lopata, R G P; Nillesen, M M; Thijssen, J M; De Korte, C L [Clinical Physics Laboratory, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Verrijp, C N; Lammens, M M Y; Van der Laak, J A W M [Department of Pathology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Singh, S K; Van Wetten, H B [Department of Cardiothoracic Surgery, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Kapusta, L [Pediatric Cardiology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)], E-mail: R.Lopata@cukz.umcn.nl

    2010-02-21

    In this study, first we propose a biplane strain imaging method using a commercial ultrasound system, yielding estimation of the strain in three orthogonal directions. Secondly, an animal model of a child's heart was introduced that is suitable to simulate congenital heart disease and was used to test the method in vivo. The proposed approach can serve as a framework to monitor the development of cardiac hypertrophy and fibrosis. A 2D strain estimation technique using radio frequency (RF) ultrasound data was applied. Biplane image acquisition was performed at a relatively low frame rate (<100 Hz) using a commercial platform with an RF interface. For testing the method in vivo, biplane image sequences of the heart were recorded during the cardiac cycle in four dogs with an aortic stenosis. Initial results reveal the feasibility of measuring large radial, circumferential and longitudinal cumulative strain (up to 70%) at a frame rate of 100 Hz. Mean radial strain curves of a manually segmented region-of-interest in the infero-lateral wall show excellent correlation between the measured strain curves acquired in two perpendicular planes. Furthermore, the results show the feasibility and reproducibility of assessing radial, circumferential and longitudinal strains simultaneously. In this preliminary study, three beagles developed an elevated pressure gradient over the aortic valve ({delta}p: 100-200 mmHg) and myocardial hypertrophy. One dog did not develop any sign of hypertrophy ({delta}p = 20 mmHg). Initial strain (rate) results showed that the maximum strain (rate) decreased with increasing valvular stenosis (-50%), which is in accordance with previous studies. Histological findings corroborated these results and showed an increase in fibrotic tissue for the hearts with larger pressure gradients (100, 200 mmHg), as well as lower strain and strain rate values.

  5. Cardiac biplane strain imaging: initial in vivo experience

    International Nuclear Information System (INIS)

    Lopata, R G P; Nillesen, M M; Thijssen, J M; De Korte, C L; Verrijp, C N; Lammens, M M Y; Van der Laak, J A W M; Singh, S K; Van Wetten, H B; Kapusta, L

    2010-01-01

    In this study, first we propose a biplane strain imaging method using a commercial ultrasound system, yielding estimation of the strain in three orthogonal directions. Secondly, an animal model of a child's heart was introduced that is suitable to simulate congenital heart disease and was used to test the method in vivo. The proposed approach can serve as a framework to monitor the development of cardiac hypertrophy and fibrosis. A 2D strain estimation technique using radio frequency (RF) ultrasound data was applied. Biplane image acquisition was performed at a relatively low frame rate (<100 Hz) using a commercial platform with an RF interface. For testing the method in vivo, biplane image sequences of the heart were recorded during the cardiac cycle in four dogs with an aortic stenosis. Initial results reveal the feasibility of measuring large radial, circumferential and longitudinal cumulative strain (up to 70%) at a frame rate of 100 Hz. Mean radial strain curves of a manually segmented region-of-interest in the infero-lateral wall show excellent correlation between the measured strain curves acquired in two perpendicular planes. Furthermore, the results show the feasibility and reproducibility of assessing radial, circumferential and longitudinal strains simultaneously. In this preliminary study, three beagles developed an elevated pressure gradient over the aortic valve (Δp: 100-200 mmHg) and myocardial hypertrophy. One dog did not develop any sign of hypertrophy (Δp = 20 mmHg). Initial strain (rate) results showed that the maximum strain (rate) decreased with increasing valvular stenosis (-50%), which is in accordance with previous studies. Histological findings corroborated these results and showed an increase in fibrotic tissue for the hearts with larger pressure gradients (100, 200 mmHg), as well as lower strain and strain rate values.

  6. Initial experience of functional imaging of upper urinary tract neoplasm by diffusion-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yoshida, Soichiro; Masuda, Hitoshi; Saito, Kazutaka; Kawakami, Satoru; Kihara, Kazunori; Ishii, Chikako

    2008-01-01

    Diffusion-weighted (DW) magnetic resonance imaging (MRI) provides functional information widely used in the diagnosis of acute cerebral stroke. We reported our initial experience of this imaging technique of upper urinary tract (UUT) urothelial carcinoma (UC). Diffusion-weighted magnetic resonance imaging was carried out in 10 consecutive patients with suspected UUT UC. With conventional imaging, seven were diagnosed as having renal pelvic tumors and two were highly suspected of having UUT UC. These nine patients were diagnosed histopathologically as having renal pelvic UC by subsequent operation. The last patient was confirmed as experiencing benign stenosis. DW MRI was obtained with a 1.5-T MR imager without a breath-holding sequence. The apparent diffusion coefficient (ADC) values of renal parenchyma, dilated collecting system, and tumor were calculated. The differences were analyzed using Wilcoxon t-test. On DW MRI, all nine tumors showed hyperintensity with negligible urinary intensity. Two cases of highly suspected UUT UC with unclear conventional MRI had high signal intensity and contrast. The case of benign stenosis had negative DW MRI. The median (range) ADC value of the tumor (0.803 [0.412-0.958] x 10 -3 mm 2 /s) was significantly lower than those of the dilated collecting system (2.19 [1.42-2.40] x 10 -3 ) and renal parenchyma (1.28 [0.922-1.45] x 10 -3 , respectively (P<0.01 and P<0.01). This is the first report on the application of DW MRI for a series of UUT UC. With this technique, a clear demonstration of UUT UC could be obtained. Moreover, this imaging technique is potentially useful to identify small lesions if they have a low diffusion coefficient. (author)

  7. Cardiac biplane strain imaging: initial in vivo experience

    Science.gov (United States)

    Lopata, R. G. P.; Nillesen, M. M.; Verrijp, C. N.; Singh, S. K.; Lammens, M. M. Y.; van der Laak, J. A. W. M.; van Wetten, H. B.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.

    2010-02-01

    In this study, first we propose a biplane strain imaging method using a commercial ultrasound system, yielding estimation of the strain in three orthogonal directions. Secondly, an animal model of a child's heart was introduced that is suitable to simulate congenital heart disease and was used to test the method in vivo. The proposed approach can serve as a framework to monitor the development of cardiac hypertrophy and fibrosis. A 2D strain estimation technique using radio frequency (RF) ultrasound data was applied. Biplane image acquisition was performed at a relatively low frame rate (dogs with an aortic stenosis. Initial results reveal the feasibility of measuring large radial, circumferential and longitudinal cumulative strain (up to 70%) at a frame rate of 100 Hz. Mean radial strain curves of a manually segmented region-of-interest in the infero-lateral wall show excellent correlation between the measured strain curves acquired in two perpendicular planes. Furthermore, the results show the feasibility and reproducibility of assessing radial, circumferential and longitudinal strains simultaneously. In this preliminary study, three beagles developed an elevated pressure gradient over the aortic valve (Δp: 100-200 mmHg) and myocardial hypertrophy. One dog did not develop any sign of hypertrophy (Δp = 20 mmHg). Initial strain (rate) results showed that the maximum strain (rate) decreased with increasing valvular stenosis (-50%), which is in accordance with previous studies. Histological findings corroborated these results and showed an increase in fibrotic tissue for the hearts with larger pressure gradients (100, 200 mmHg), as well as lower strain and strain rate values.

  8. SISCOM imaging : an initial South African experience

    International Nuclear Information System (INIS)

    Warwick, J.; Rubow, S.; Van Heerden, B.; Ghoorun, S.; Butler, J.

    2004-01-01

    Full text: Subtraction ictal SPECT co-registered with MRI (SISCOM) is a new technique utilized for the detection and localization of epileptogenic foci in patients with refractory focal epilepsy who are candidates for surgical resection. The technique requires many challenges to be overcome, in particular in relation to the administration of the radiopharmaceutical, acquisition of brain SPECT and the conversion, co-registration and fusion of brain SPECT and MRI studies. Furthermore the interpretation of the studies is complex and is ideally performed in a multidisciplinary context in cooperation with disciplines such as neurology, radiology, psychiatry and neurosurgery. Materials and methods: Two brain SPECT studies are performed using 99m Tc-ethylene cystinate dimer (ECD). An ictal study is performed after the administration of the 99m Tc-ECD during a seizure. An interictal SPECT, performed between seizures is then subtracted from the ictal SPECT, and the difference image fused with an MRI study to optimise localization of the epileptogenic focus. Image conversion, co-registration and fusion was performed using MRlcro and SPM software. Results: To date the Departments of Neurology and Nuclear Medicine have completed over 10 SISCOM studies. Conclusion: During this presentation this initial work will be presented. The methodology as well as the challenges involved in performing and interpreting these studies will be discussed. Individual cases will be used to illustrate the impact of this powerful technique on future patient management. (author)

  9. MR imaging-guided cryoablation of metastatic brain tumours: initial experience in six patients

    International Nuclear Information System (INIS)

    Li, Chengli; Wu, Lebin; Song, Jiqing; Liu, Ming; Lv, Yubo; Sequeiros, Roberto Blanco

    2010-01-01

    The objective was to evaluate the initial experience and safety of magnetic resonance imaging (MRI)-guided transcranial cryoablation in cystic metastatic brain tumours. Seven cystic metastatic brain tumours in six patients were treated with cryoablation. The approval from the local ethics committee and individual patient consent were acquired before the study. Before the procedure the tumours were detected with conventional CT or MRI. The procedure was performed under local anaesthesia and conscious sedation. A 0.23-T open MRI system with optical tracking was used for procedural planning, instrument guidance and procedural monitoring of the ice ball formation. An MR-compatible, argon-based cryoablation system was used. The schedule of follow-up imaging ranged from 12 days to 12 months. Seven treatment sessions were performed. All the cryoprobes were successfully inserted into the target with one pass. All the patients tolerated the procedure well without experiencing any neurological deficits during the treatment phase or during the immediate post-treatment period. One patient died 12 days after cryoablation. MR-guided and monitored metastasis brain tumour cryoablation is technically feasible and may represent an alternative treatment in selected patients. (orig.)

  10. SU-E-J-181: Magnetic Resonance Image-Guided Radiation Therapy Workflow: Initial Clinical Experience

    International Nuclear Information System (INIS)

    Green, O; Kashani, R; Santanam, L; Wooten, H; Li, H; Rodriguez, V; Hu, Y; Mutic, S; Hand, T; Victoria, J; Steele, C

    2014-01-01

    Purpose: The aims of this work are to describe the workflow and initial clinical experience treating patients with an MRI-guided radiotherapy (MRIGRT) system. Methods: Patient treatments with a novel MR-IGRT system started at our institution in mid-January. The system consists of an on-board 0.35-T MRI, with IMRT-capable delivery via doubly-focused MLCs on three 60 Co heads. In addition to volumetric MR-imaging, real-time planar imaging is performed during treatment. So far, eleven patients started treatment (six finished), ranging from bladder to lung SBRT. While the system is capable of online adaptive radiotherapy and gating, a conventional workflow was used to start, consisting of volumetric imaging for patient setup using visible tumor, evaluation of tumor motion outside of PTV on cine images, and real-time imaging. Workflow times were collected and evaluated to increase efficiency and evaluate feasibility of adding the adaptive and gating features while maintaining a reasonable patient throughput. Results: For the first month, physicians attended every fraction to provide guidance on identifying the tumor and an acceptable level of positioning and anatomical deviation. Average total treatment times (including setup) were reduced from 55 to 45 min after physician presence was no longer required and the therapists had learned to align patients based on soft-tissue imaging. Presently, the source strengths were at half maximum (7.7K Ci each), therefore beam-on times will be reduced after source replacement. Current patient load is 10 per day, with increase to 25 anticipated in the near future. Conclusion: On-board, real-time MRI-guided RT has been incorporated into clinical use. Treatment times were kept to reasonable lengths while including volumetric imaging, previews of tumor movement, and physician evaluation. Workflow and timing is being continuously evaluated to increase efficiency. In near future, adaptive and gating capabilities of the system will be

  11. Dual-source CT cardiac imaging: initial experience

    International Nuclear Information System (INIS)

    Johnson, Thorsten R.C.; Nikolaou, Konstantin; Wintersperger, Bernd J.; Rist, Carsten; Buhmann, Sonja; Reiser, Maximilian F.; Becker, Christoph R.; Leber, Alexander W.; Ziegler, Franz von; Knez, Andreas

    2006-01-01

    The relation of heart rate and image quality in the depiction of coronary arteries, heart valves and myocardium was assessed on a dual-source computed tomography system (DSCT). Coronary CT angiography was performed on a DSCT (Somatom Definition, Siemens) with high concentration contrast media (Iopromide, Ultravist 370, Schering) in 24 patients with heart rates between 44 and 92 beats per minute. Images were reconstructed over the whole cardiac cycle in 10% steps. Two readers independently assessed the image quality with regard to the diagnostic evaluation of right and left coronary artery, heart valves and left ventricular myocardium for the assessment of vessel wall changes, coronary stenoses, valve morphology and function and ventricular function on a three point grading scale. The image quality ratings at the optimal reconstruction interval were 1.24±0.42 for the right and 1.09±0.27 for the left coronary artery. A reconstruction of diagnostic systolic and diastolic images is possible for a wide range of heart rates, allowing also a functional evaluation of valves and myocardium. Dual-source CT offers very robust diagnostic image quality in a wide range of heart rates. The high temporal resolution now also makes a functional evaluation of the heart valves and myocardium possible. (orig.)

  12. Magnetic resonance imaging of the female pelvis: initial experience

    International Nuclear Information System (INIS)

    Hricak, H.; Alpers, C.; Crooks, L.E.; Sheldon, P.E.

    1983-01-01

    The potential of magnetic resonance imaging (MRI) was evaluated in 21 female subjects: seven volunteers, 12 patients scanned for reasons unrelated to the lower genitourinary tract, and two patients referred with gynecologic disease. The uterus at several stages was examined; the premenarcheal uterus (one patient), the uterus of reproductive age (12 patients), the postmenopausal uterus (two patients), and in an 8 week pregnancy (one patient). The myometrium and cyclic endometrium in the reproductive age separated by a low-intensity line (probably stratum basale), which allows recognition of changes in thickness of the cyclic endometrium during the menstrual cycle. The corpus uteri can be distinguished from the cervix by the transitional zone of the isthmus. The anatomic relation of the uterus to bladder and rectum is easily outlined. The vagina can be distinguished from the cervix, and the anatomic display of the closely apposed bladder, vagina, and rectum is clear on axial and coronal images. The ovary is identified; the signal intensity from the ovary depends on the acquisition parameter used. Uterine leiomyoma, endometriosis, and dermoid cyst were depicted, but further experience is needed to ascertain the specificity of the findings

  13. Implementation of a patient dose monitoring system in conventional digital X-ray imaging: initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Heilmaier, Christina; Zuber, Niklaus; Weishaupt, Dominik [Stadtspital Triemli Zurich, Department of Radiology and Nuclear Medicine, Zurich (Switzerland)

    2017-03-15

    The purpose was to report on the initial experience after implementation of a patient dose-monitoring system in conventional X-ray imaging. A dose-monitoring system collected dose data relating to different radiographs (one projection) and studies (two or more projections). Images were acquired on digital X-ray systems equipped with flat-panel detectors. During period 1, examinations were performed in a routine fashion in 12,614 patients. After period 1, technical modifications were performed and radiographers underwent training in radiation protection. During period 2, examinations were performed in 14,514 patients, and the radiographers were advised to read dose data after each radiograph/study. Dose data were compared by means of kerma area product (KAP, gray x centimetre squared) and entrance surface air kerma (ESAK, milligray). During period 1, 13,955 radiographs and 8,466 studies were performed, and in period 2 16,090 radiographs and 10,389 studies. In period 2, KAP values for radiographs were an average of 25 % lower and for studies 7 % lower, and ESAK values for radiographs were 24 % lower and for studies 5 % lower. The reduction in KAP was significant in 8/13 radiographs and in 6/14 studies, and the reduction in ESAK was significant in 6/13 radiographs and 5/14 studies. Implementation of a patient dose-monitoring system in conventional X-ray imaging allows easy data collection, supports dose reduction efforts, and may increase radiographers' dose awareness. (orig.)

  14. Cardiac 82rubidium PET/CT: initial European experience

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Dickson, John C.; Kayani, Irfan; Endozo, Raymondo; Blanchard, Patty; Shastry, Manu; Prvulovich, Elizabeth; Waddington, Wendy A.; Ben-Haim, Simona; Bomanji, Jamshed B.; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean R.

    2007-01-01

    Myocardial perfusion with PET/CT has advantages over conventional SPECT. We describe our initial European experience using 82 Rubidium-PET/CT, as part of a clinical myocardial perfusion service. We studied the first 100 patients (64 male; 36 female, mean age = 60: SD +/-12.5y, mean body mass index = 30: SD +/-6.9kg/m 2 ) who underwent 82 Rubidium cardiac PET/CT in our institution. Thirty patients had recently undergone coronary angiography. Patients underwent imaging during adenosine infusion and at rest. Images were acquired over 5 minutes using a GE-PET/CT instrument. Image quality was described as good, adequate or inadequate. Images were reported patient-by-patient by a minimum of five nuclear medicine physicians. A segment-by-segment analysis (17-segment model) was also performed. Image quality was good in 77%, adequate 23% and inadequate 0%. There was no statistical difference in image quality between obese and non-obese patients (Fisher's exact test, p = 0.2864). 59% had normal perfusion studies, 29% had inducible ischaemia, 12% had myocardial infarction (11% with super added ischaemia). There was reduced 82 Rubidium uptake in 132/1700 segments during stress. There was reduced 82 Rubidium uptake at rest in 42/1700 segments. The 82 Rubidium PET/CT findings were consistent with the angiographic findings in 28/30 cases. We show that, even from initial use of 82 Rubidium, it is possible to perform myocardial perfusion studies quickly with good image quality, even in the obese. The PET findings correlated well in the third of the cases where angiography was available. As such, 82 Rubidium cardiac PET/CT is likely to be an exciting addition to the European nuclear physician/ cardiologist's radionuclide imaging arsenal. (orig.)

  15. The correlation of in vivo and ex vivo tissue dielectric properties to validate electromagnetic breast imaging: initial clinical experience

    International Nuclear Information System (INIS)

    Halter, Ryan J; Zhou, Tian; Meaney, Paul M; Hartov, Alex; Barth, Richard J Jr; Rosenkranz, Kari M; Wells, Wendy A; Kogel, Christine A; Borsic, Andrea; Rizzo, Elizabeth J; Paulsen, Keith D

    2009-01-01

    Electromagnetic (EM) breast imaging provides low-cost, safe and potentially a more specific modality for cancer detection than conventional imaging systems. A primary difficulty in validating these EM imaging modalities is that the true dielectric property values of the particular breast being imaged are not readily available on an individual subject basis. Here, we describe our initial experience in seeking to correlate tomographic EM imaging studies with discrete point spectroscopy measurements of the dielectric properties of breast tissue. The protocol we have developed involves measurement of in vivo tissue properties during partial and full mastectomy procedures in the operating room (OR) followed by ex vivo tissue property recordings in the same locations in the excised tissue specimens in the pathology laboratory immediately after resection. We have successfully applied all of the elements of this validation protocol in a series of six women with cancer diagnoses. Conductivity and permittivity gauged from ex vivo samples over the frequency range 100 Hz–8.5 GHz are found to be similar to those reported in the literature. A decrease in both conductivity and permittivity is observed when these properties are gauged from ex vivo samples instead of in vivo. We present these results in addition to a case study demonstrating how discrete point spectroscopy measurements of the tissue can be correlated and used to validate EM imaging studies

  16. Axial oblique MR imaging of the intrinsic ligaments of the wrist: initial experience

    International Nuclear Information System (INIS)

    Robinson, G.; Chung, T.; Finlay, K.; Friedman, L.

    2006-01-01

    To evaluate two separate MR sequences acquired in the axial oblique plane, parallel to the long axis of the scapholunate (SL) and lunotriquetral (LT) ligaments, to determine whether the addition of these sequences to the standard MR wrist examination improves visualization of the intrinsic ligaments, and the evaluation of their integrity. To our knowledge, this plane has not been described in the literature previously. In total we evaluated 26 patients with chronic wrist pain or instability, referred for MR imaging following assessment by an orthopedic surgeon or physiatrist. All patients underwent initial conventional tri-compartment wrist arthrography, which served as the reference standard. This was immediately followed by MR arthrography, in the standard coronal and true axial planes, as well as in the axial oblique plane. The SL and LT ligaments were initially assessed for the presence or absence of tear, using the standard coronal and true axial sequences, and subsequently re-evaluated with the addition of the axial oblique planes. A total of ten intrinsic ligament tears were identified with conventional arthrography: six SL and four LT tears. Five of the six SL tears were identified on the standard sequences. All six were diagnosed with the addition of the oblique sequences. There were three false-positive SL tears identified using standard MR imaging, and two false-positives with the addition of the oblique sequences. No LT tear was identified on standard sequences, whereas all four were confidently seen with the addition of oblique images. No false-positives of the LT ligament were recorded with either standard or axial oblique sequences. The study suggests that the addition of axial oblique MR sequences helps identify tears to the intrinsic ligaments of the wrist, particularly the LT ligament. In addition, the axial oblique images assist in localization of the tear. (orig.)

  17. Fusion imaging of computed tomographic pulmonary angiography and SPECT ventilation/perfusion scintigraphy: initial experience and potential benefit

    International Nuclear Information System (INIS)

    Harris, Benjamin; Bailey, Dale; Roach, Paul; Bailey, Elizabeth; King, Gregory

    2007-01-01

    The objective of this study was to examine the feasibility of fusing ventilation and perfusion data from single-photon emission computed tomography (SPECT) ventilation perfusion (V/Q) scintigraphy together with computed tomographic pulmonary angiography (CTPA) data. We sought to determine the accuracy of this fusion process. In addition, we correlated the findings of this technique with the final clinical diagnosis. Thirty consecutive patients (17 female, 13 male) who had undergone both CTPA and SPECT V/Q scintigraphy during their admission for investigation of potential pulmonary embolism were identified retrospectively. Image datasets from these two modalities were co-registered and fused using commercial software. Accuracy of the fusion process was determined subjectively by correlation between modalities of the anatomical boundaries and co-existent pleuro-parenchymal abnormalities. In all 30 cases, SPECT V/Q images were accurately fused with CTPA images. An automated registration algorithm was sufficient alone in 23 cases (77%). Additional linear z-axis scaling was applied in seven cases. There was accurate topographical co-localisation of vascular, parenchymal and pleural disease on the fused images. Nine patients who had positive CTPA performed as an initial investigation had co-localised perfusion defects on the subsequent fused CTPA/SPECT images. Three of the 11 V/Q scans initially reported as intermediate could be reinterpreted as low probability owing to co-localisation of defects with parenchymal or pleural pathology. Accurate fusion of SPECT V/Q scintigraphy to CTPA images is possible. This technique may be clinically useful in patients who have non-diagnostic initial investigations or in whom corroborative imaging is sought. (orig.)

  18. Magnetic resonance spectroscopy imaging in the diagnosis of prostate cancer: initial experience

    International Nuclear Information System (INIS)

    Melo, Homero Jose de Farias e; Abdala, Nitamar; Goldman, Suzan Menasce; Szejnfeld, Jacob

    2009-01-01

    Objective: to report an experiment involving the introduction of a protocol utilizing commercially available three-dimensional 1H magnetic resonance spectroscopy imaging (3D 1H MRSI) method in patients diagnosed with prostatic tumors under suspicion of neoplasm. Materials and methods: forty-one patients in the age range between 51 and 80 years (mean, 67 years) were prospectively evaluated. The patients were divided into two groups: patients with one or more biopsies negative for cancer and high specific-prostatic antigen levels (group A), and patients with cancer confirmed by biopsy (group B). The determination of the target area (group A) or the known cancer extent (group B) was based on magnetic resonance imaging and MRSI studies. Results: the specificity of MRSI in the diagnosis of prostate cancer was lower than the specificity reported in the literature (about 47%). On the other hand, for tumor staging, it corresponded to the specificity reported in the literature. Conclusion: the introduction and standardization of 3D 1H MRSI has allowed the obtention of a presumable diagnosis of prostate cancer, by a combined analysis of magnetic resonance imaging and metabolic data from 3D 1H MRSI. (author)

  19. Development of a new compact intraoperative magnetic resonance imaging system: concept and initial experience.

    Science.gov (United States)

    Morita, Akio; Sameshima, Tetsuro; Sora, Shigeo; Kimura, Toshikazu; Nishimura, Kengo; Itoh, Hirotaka; Shibahashi, Keita; Shono, Naoyuki; Machida, Toru; Hara, Naoko; Mikami, Nozomi; Harihara, Yasushi; Kawate, Ryoichi; Ochiai, Chikayuki; Wang, Weimin; Oguro, Toshiki

    2014-06-01

    Magnetic resonance imaging (MRI) during surgery has been shown to improve surgical outcomes, but the current intraoperative MRI systems are too large to install in standard operating suites. Although 1 compact system is available, its imaging quality is not ideal. We developed a new compact intraoperative MRI system and evaluated its use for safety and efficacy. This new system has a magnetic gantry: a permanent magnet of 0.23 T and an interpolar distance of 32 cm. The gantry system weighs 2.8 tons and the 5-G line is within the circle of 2.6 m. We created a new field-of-view head coil and a canopy-style radiofrequency shield for this system. A clinical trial was initiated, and the system has been used in 44 patients. This system is significantly smaller than previous intraoperative MRI systems. High-quality T2 images could discriminate tumor from normal brain tissue and identify anatomic landmarks for accurate surgery. The average imaging time was 45.5 minutes, and no clinical complications or MRI system failures occurred. Floating organisms or particles were minimal (1/200 L maximum). This intraoperative, compact, low-magnetic-field MRI system can be installed in standard operating suites to provide relatively high-quality images without sacrificing safety. We believe that such a system facilitates the introduction of the intraoperative MRI.

  20. Motion-Corrected Real-Time Cine Magnetic Resonance Imaging of the Heart: Initial Clinical Experience.

    Science.gov (United States)

    Rahsepar, Amir Ali; Saybasili, Haris; Ghasemiesfe, Ahmadreza; Dolan, Ryan S; Shehata, Monda L; Botelho, Marcos P; Markl, Michael; Spottiswoode, Bruce; Collins, Jeremy D; Carr, James C

    2018-01-01

    Free-breathing real-time (RT) imaging can be used in patients with difficulty in breath-holding; however, RT cine imaging typically experiences poor image quality compared with segmented cine imaging because of low resolution. Here, we validate a novel unsupervised motion-corrected (MOCO) reconstruction technique for free-breathing RT cardiac images, called MOCO-RT. Motion-corrected RT uses elastic image registration to generate a single heartbeat of high-quality data from a free-breathing RT acquisition. Segmented balanced steady-state free precession (bSSFP) cine images and free-breathing RT images (Cartesian, TGRAPPA factor 4) were acquired with the same spatial/temporal resolution in 40 patients using clinical 1.5 T magnetic resonance scanners. The respiratory cycle was estimated using the reconstructed RT images, and nonrigid unsupervised motion correction was applied to eliminate breathing motion. Conventional segmented RT and MOCO-RT single-heartbeat cine images were analyzed to evaluate left ventricular (LV) function and volume measurements. Two radiologists scored images for overall image quality, artifact, noise, and wall motion abnormalities. Intraclass correlation coefficient was used to assess the reliability of MOCO-RT measurement. Intraclass correlation coefficient showed excellent reliability (intraclass correlation coefficient ≥ 0.95) of MOCO-RT with segmented cine in measuring LV function, mass, and volume. Comparison of the qualitative ratings indicated comparable image quality for MOCO-RT (4.80 ± 0.35) with segmented cine (4.45 ± 0.88, P = 0.215) and significantly higher than conventional RT techniques (3.51 ± 0.41, P cine (1.51 ± 0.90, P = 0.088 and 1.23 ± 0.45, P = 0.182) were not different. Wall motion abnormality ratings were comparable among different techniques (P = 0.96). The MOCO-RT technique can be used to process conventional free-breathing RT cine images and provides comparable quantitative assessment of LV function and volume

  1. MR imaging of patients with localisation-related seizures: initial experience at 3.0T and relevance to the NICE guidelines

    International Nuclear Information System (INIS)

    Griffiths, P.D.; Coley, S.C.; Connolly, D.J.A.; Hodgson, T.; Romanowski, C.A.J.; Widjaja, E.; Darwent, G.; Wilkinson, I.D.

    2005-01-01

    The purpose of this study is to describe our initial experience of imaging adults with localisation-related epilepsy using MR imaging at 3.0T. We discuss the findings in the context of the recently released NICE guidelines that provide detailed advice on imaging people with epilepsy in the UK. 120 consecutive people over the age of 16 years with localisation-related epilepsy were referred for clinical MR examinations from a regional neuroscience centre in England. None of the people had had MR examinations prior to the present study. High resolution MR imaging was performed taking advantage of the high field strength and high performance gradients of the system. Two experienced neuroradiologists reported on the examinations independently and the presence and type of pathology was recorded. There was complete agreement between the two reporters in all 120 cases. The overall frequency of abnormalities shown by MR was 31/120 (26%) and the commonest abnormality shown was mesial temporal sclerosis found in 10/120 (8%). Tumours were shown in 4/120, all of which appeared low grade as judged by imaging criteria. Epilepsy is the commonest neurological condition and demands a significant resource in order to provide good care for sufferers. Recent guidelines published in the UK have suggested that the majority of people with epilepsy should receive brain MR as part of their routine assessment. Our work shows that using the most sophisticated MR imaging in a highly selected population there is a modest pick-up rate of brain abnormalities. If a widespread epilepsy-imaging programme is started the detection rate is likely to be much lower. Although MR is acknowledged to be a reliable way of detecting pathology in people with epilepsy there is a dearth of information studying the health economics of imaging epilepsy in relation to patient management and outcomes

  2. Pictures, images, and recollective experience.

    Science.gov (United States)

    Dewhurst, S A; Conway, M A

    1994-09-01

    Five experiments investigated the influence of picture processing on recollective experience in recognition memory. Subjects studied items that differed in visual or imaginal detail, such as pictures versus words and high-imageability versus low-imageability words, and performed orienting tasks that directed processing either toward a stimulus as a word or toward a stimulus as a picture or image. Standard effects of imageability (e.g., the picture superiority effect and memory advantages following imagery) were obtained only in recognition judgments that featured recollective experience and were eliminated or reversed when recognition was not accompanied by recollective experience. It is proposed that conscious recollective experience in recognition memory is cued by attributes of retrieved memories such as sensory-perceptual attributes and records of cognitive operations performed at encoding.

  3. Clinical multi-colour fluorescence imaging of malignant tumours - initial experience

    International Nuclear Information System (INIS)

    Svanberg, K.; Wang, I.; Montan, S.; Andersson-Engels, S.; Svanberg, S.; Lund Inst. of Technology

    1998-01-01

    The purpose of this study was to present a new technique for non-invasive tumour detection based on tissue fluorescence imaging. A clinically adapted multi-colour fluorescence system was employed in the real-time imaging of malignant tumours of the skin, breast, head and neck region, and urinary bladder. Tumour detection was based on the contrast displayed in fluorescence between normal and malignant tissue, related to the selective uptake of tumour-marking agents and natural chromophore differences between various tissues. In order to demarcate basal cell carcinomas of the skin, ALA was applied topically 4-6 h before the fluorescence investigation. For urinary bladder tumour visualisation, ALA was instilled into the bladder 1-2 h prior to the study. Malignant and premalignant lesions in the head and neck region were imaged after i.v. injection of HPD (Photofrin). The tumour imaging system was coupled to an endoscope. Fluorescence light emission from the tissue surface was induced with 100-ns-long optical pulses at 390 nm, generated from a frequency-doubled alexandrite laser. With the use of special image-splitting optics, the tumour fluorescence, intensified in a micro-channel plate, was imaged in 3 selected wavelength bands. These 3 images were processed together to form a new optimised-contrast image of the tumour. This image, updated at a rate of about 3 frames/s was mixed with a normal colour video image of the tissue. A clear demarcation from normal surrounding tissue was found during in vivo measurements of superficial bladder carcinoma, basal cell carcinoma of the skin, and leukoplakia with dysplasia of the lip, and in vitro investigations of resected breast cancer. (orig./MG)

  4. EXPERIENCES WITH IDEA PROMOTING INITIATIVES

    DEFF Research Database (Denmark)

    Gish, Liv

    2011-01-01

    In new product development a central activity is to provide new ideas. Over the last decades experiences with stimulating employee creativity and establishing idea promoting initiatives have been made in industrial practice. Such initiatives are often labeled Idea Management – a research field...... with a growing interest. In this paper I examine three different idea promoting initiatives carried out in Grundfos, a leading pump manufacturer. In the analysis I address what understandings of idea work are inscribed in the initiatives and what role these initiatives play in the organization with respect...... understandings of idea work are inscribed in the idea promoting initiatives as they to some degree have to fit with the understandings embedded in practice in order to work....

  5. Initial conditions of radiative shock experiments

    International Nuclear Information System (INIS)

    Kuranz, C. C.; Drake, R. P.; Krauland, C. M.; Marion, D. C.; Grosskopf, M. J.; Rutter, E.; Torralva, B.; Holloway, J. P.; Bingham, D.; Goh, J.; Boehly, T. R.; Sorce, A. T.

    2013-01-01

    We performed experiments at the Omega Laser Facility to characterize the initial, laser-driven state of a radiative shock experiment. These experiments aimed to measure the shock breakout time from a thin, laser-irradiated Be disk. The data are then used to inform a range of valid model parameters, such as electron flux limiter and polytropic γ, used when simulating radiative shock experiments using radiation hydrodynamics codes. The characterization experiment and the radiative shock experiment use a laser irradiance of ∼7 × 10 14 W cm −2 to launch a shock in the Be disk. A velocity interferometer and a streaked optical pyrometer were used to infer the amount of time for the shock to move through the Be disk. The experimental results were compared with simulation results from the Hyades code, which can be used to model the initial conditions of a radiative shock system using the CRASH code

  6. Cardiac biplane strain imaging: initial in vivo experience.

    NARCIS (Netherlands)

    Lopata, R.G.P.; Nillesen, M.M.; Verrijp, C.N.; Singh, S.K.; Lammens, M.M.Y.; Laak, J.A.W.M. van der; Wetten, H.B. van; Thijssen, J.M.; Kapusta, L.; Korte, C.L. de

    2010-01-01

    In this study, first we propose a biplane strain imaging method using a commercial ultrasound system, yielding estimation of the strain in three orthogonal directions. Secondly, an animal model of a child's heart was introduced that is suitable to simulate congenital heart disease and was used to

  7. Prototype radiographic system for emergency and intensive care units: Initial experience

    International Nuclear Information System (INIS)

    Mirvis, S.

    1986-01-01

    A prototype radiographic system has been developed for use in bedside examinations in multibed trauma or intensive care units and emergency rooms. The system features a single-phase, high-frequency 30-kW ceiling-mounted generator with an x-ray tube extending from a long counterbalanced arm. All movements are servo-assisted for ease of operation. Based on initial experience, the unit allows easier access to the patient around resuscitation and monitoring equipment, occupies less floor space, and yields better quality images than do standard mobile radiographic units

  8. Destination visual image and expectation of experiences

    DEFF Research Database (Denmark)

    Ye, H.; Tussyadiah, Iis

    2011-01-01

    A unique experience is the essence of tourism sought by tourists. The most effective way to communicate the notion of a tourism experience at a destination is to provide visual cues that stimulate the imagination and connect with potential tourists in a personal way. This study aims...... at understanding how a visual image is relevant to the expectation of experiences by deconstructing images of a destination and interpreting visitors' perceptions of these images and the experiences associated with them. The results suggest that tourists with different understandings of desirable experiences found...

  9. Return to Experience and Initial Wage Level

    DEFF Research Database (Denmark)

    Sørensen, Kenneth Lykke; Vejlin, Rune Majlund

    This paper estimates the relationship between initial wage and return to experience. We use a Mincer-like wage model to nonparametrically estimate this relationship allowing for an unobservable individual permanent effect in wages and unobservable individual return to experience. The relationship...

  10. Intravoxel incoherent motion perfusion imaging in acute stroke: initial clinical experience

    International Nuclear Information System (INIS)

    Federau, C.; Becce, F.; Maeder, P.; Meuli, R.; Sumer, S.; Wintermark, M.; O'Brien, K.

    2014-01-01

    Intravoxel incoherent motion (IVIM) imaging is an MRI perfusion technique that uses a diffusion-weighted sequence with multiple b values and a bi-compartmental signal model to measure the so-called pseudo-diffusion of blood caused by its passage through the microvascular network. The goal of the current study was to assess the feasibility of IVIM perfusion fraction imaging in patients with acute stroke. Images were collected in 17 patients with acute stroke. Exclusion criteria were onset of symptoms to imaging >5 days, hemorrhagic transformation, infratentorial lesions, small lesions 2 . Image quality was assessed by two radiologists, and quantitative analysis was performed in regions of interest placed in the stroke area, defined by thresholding the apparent diffusion coefficient maps, as well as in the contralateral region. IVIM perfusion fraction maps showed an area of decreased perfusion fraction f in the region of decreased apparent diffusion coefficient. Quantitative analysis showed a statistically significant decrease in both IVIM perfusion fraction f (0.026 ± 0.019 vs. 0.056 ± 0.025, p = 2.2 . 10 -6 ) and diffusion coefficient D compared with the contralateral side (3.9 ± 0.79 . 10 -4 vs. 7.5 ± 0.86 . 10 -4 mm 2 /s, p = 1.3 . 10 -20 ). IVIM perfusion fraction imaging is feasible in acute stroke. IVIM perfusion fraction is significantly reduced in the visible infarct. Further studies should evaluate the potential for IVIM to predict clinical outcome and treatment response. (orig.)

  11. UV imaging for in vitro dissolution and release studies: Initial experiences

    DEFF Research Database (Denmark)

    Østergaard, Jesper; Lenke, James; Jensen, Sabrine Smedegaard

    2014-01-01

    UV imaging has recently been introduced as a method in drug dissolution and release testing. Spatially and temporally resolved mapping of drug oncentrations in a 7 × 9 mm imaging area provides new opportunities for visualization and study of drug dissolution and release. This review describes...... in hydrogels with relevance for characterization of parenteral depots. UV imaging may be of particular use when the amounts of material are sparse and detailed insights into dissolution and release processes are required, that is in solid form screening, preformulation, and early drug development....

  12. Return to experience and initial wage level

    DEFF Research Database (Denmark)

    Sørensen, K.L.; Vejlin, R.

    2014-01-01

    This paper estimates the relationship between initial wage and return to experience. We use a Mincer-like wage model to non-parametrically estimate this relationship allowing for an unobservable individual permanent effect in wages and unobservable individual return to experience. The relationshi...

  13. Holography Experiments on Optical Imaging.

    Science.gov (United States)

    Bonczak, B.; Dabrowski, J.

    1979-01-01

    Describes experiments intended to produce a better understanding of the holographic method of producing images and optical imaging by other optical systems. Application of holography to teaching physics courses is considered. (Author/SA)

  14. Initial state radiation experiment at MAMI

    Energy Technology Data Exchange (ETDEWEB)

    Mihovilovič, M.; Merkel, H. [Institut für Kernphysik, Johannes Gutenberg-Universität Mainz, Johann-Joachim-Becher-Weg 45, 55128 Mainz (Germany); Collaboration: A1-Collaboration

    2013-11-07

    In an attempt to contribute further insight into the discrepancy between the Lamb shift and elastic scattering determinations of the proton charge radius, a new experiment at MAMI is underway, aimed at measuring proton form-factors at very low momentum transfers by using a new technique based on initial state radiation. This paper reports on first findings of the pilot measurement performed in 2010, whose main goal was to check the feasibility of the proposed experiment and to recognize and overcome potential obstacles before running the full experiment in 2013.

  15. SU-F-T-261: Reconstruction of Initial Photon Fluence Based On EPID Images

    Energy Technology Data Exchange (ETDEWEB)

    Seliger, T; Engenhart-Cabillic, R [Philipp University of Marburg, Marburg (Germany); Czarnecki, D; Maeder, U; Zink, K [Technische Hochschule Mittelhessen - University of Applied Sciences, Giessen (Germany); Kussaether, R [MedCom GmbH, Darmstadt (Germany); Poppe, B [University Hospital for Medical Radiation Physics, Pius-Hospital, Medical Campus, Carl von Ossietzky University of Oldenburg (Germany)

    2016-06-15

    Purpose: Verifying an algorithm to reconstruct relative initial photon fluence for clinical use. Clinical EPID and CT images were acquired to reconstruct an external photon radiation treatment field. The reconstructed initial photon fluence could be used to verify the treatment or calculate the applied dose to the patient. Methods: The acquired EPID images were corrected for scatter caused by the patient and the EPID with an iterative reconstruction algorithm. The transmitted photon fluence behind the patient was calculated subsequently. Based on the transmitted fluence the initial photon fluence was calculated using a back-projection algorithm which takes the patient geometry and its energy dependent linear attenuation into account. This attenuation was gained from the acquired cone-beam CT or the planning CT by calculating a water-equivalent radiological thickness for each irradiation direction. To verify the algorithm an inhomogeneous phantom consisting of three inhomogeneities was irradiated by a static 6 MV photon field and compared to a reference flood field image. Results: The mean deviation between the reconstructed relative photon fluence for the inhomogeneous phantom and the flood field EPID image was 3% rising up to 7% for off-axis fluence. This was probably caused by the used clinical EPID calibration, which flattens the inhomogeneous fluence profile of the beam. Conclusion: In this clinical experiment the algorithm achieved good results in the center of the field while it showed high deviation of the lateral fluence. This could be reduced by optimizing the EPID calibration, considering the off-axis differential energy response. In further progress this and other aspects of the EPID, eg. field size dependency, CT and dose calibration have to be studied to realize a clinical acceptable accuracy of 2%.

  16. Ultrasound-guided Breast Biopsy in the Resource-limited Setting: An Initial Experience in Rural Uganda

    Directory of Open Access Journals (Sweden)

    Christopher R. Stark

    2017-06-01

    Full Text Available Purpose: To describe the methodology and initial experience behind creation of an ultrasoundguided percutaneous breast core biopsy program in rural Uganda. Methods and Materials: Imaging the World Africa (ITWA is the registered non-governmental organization division of Imaging the World (ITW, a not-for-profit organization whose primary aim is the integration of affordable high-quality ultrasound into rural health centers. In 2013, ITWA began the pilot phase of an IRB-approved breast care protocol at a rural health center in Uganda. As part of the protocol’s diagnostic arm, an ultrasound-guided percutaneous breast core biopsy training curriculum was implemented in tandem with creation of regionally supplied biopsy kits. Results: A surgeon at a rural regional referral hospital was successfully trained and certified to perform ultrasound-guided percutaneous breast core biopsies. Affordable and safe biopsy kits were created using locally available medical supplies with the cost of each kit totaling $10.62 USD. Conclusion: Successful implementation of an ultrasound-guided percutaneous breast core biopsy program in the resource-limited setting is possible and can be made sustainable through incorporation of local health care personnel and regionally supplied biopsy materials. Our hope is that ITWA’s initial experience in rural Uganda can serve as a model for similar programs in the future.

  17. Initial experience with AcQsim CT simulator

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Gerber, Russell; Bosch, Walter R.; Harms, William; Matthews, John W.; Purdy, James A.; Perez, Carlos A.

    1995-01-01

    Purpose: We recently replaced our university developed CT simulator prototype with a commercial grade spiral CT simulator (Picker AcQsim) that is networked with three independent virtual simulation workstations and our 3D radiation therapy planning (3D-RTP) system multiple workstations. This presentation will report our initial experience with this CT simulation device and define criteria for optimum clinical use as well as describe some potential drawbacks of the current system. Methods and Materials: Over a 10 month period, 210 patients underwent CT simulation using the AcQsim. An additional 127 patients had a volumetric CT scan done on the device with their CT data and target and normal tissue contours ultimately transferred to our 3D-RTP system. We currently perform the initial patient localization and immobilization in the CT simulation suite by using CT topograms and a fiducial laser marking system. Immobilization devices, required for all patients undergoing CT simulation, are constructed and registered to a device that defines the treatment table coordinates. Orthogonal anterior and lateral CT topograms document patient alignment and the position of a reference coordinate center. The volumetric CT scan with appropriate CT contrast materials administered is obtained while the patient is in the immobilization device. On average, more than 100 CT slices are obtained per study. Contours defining tumor, target, and normal tissues are drawn on a slice by slice basis. Isocenter definition can be automatically defined within the target volume and marked on the patient and immobilization device before leaving the initial CT simulation session. Virtual simulation is then performed on the patient data set with the assistance of predefined target volumes and normal tissue contours displayed on rapidly computed digital reconstructed radiographs (DRRs) in a manner similar to a conventional fluoroscopic radiotherapy simulator. Lastly, a verification simulation is

  18. Initial experiments with gel-water: towards MRI-linac dosimetry and imaging.

    Science.gov (United States)

    Alnaghy, Sarah J; Gargett, Maegan; Liney, Gary; Petasecca, Marco; Begg, Jarrad; Espinoza, Anthony; Newall, Matthew K; Duncan, Mitchell; Holloway, Lois; Lerch, Michael L F; Lazea, Mircea; Rosenfeld, Anatoly B; Metcalfe, Peter

    2016-12-01

    Tracking the position of a moving radiation detector in time and space during data acquisition can replicate 4D image-guided radiotherapy (4DIGRT). Magnetic resonance imaging (MRI)-linacs need MRI-visible detectors to achieve this, however, imaging solid phantoms is an issue. Hence, gel-water, a material that provides signal for MRI-visibility, and which will in future work, replace solid water for an MRI-linac 4DIGRT quality assurance tool, is discussed. MR and CT images of gel-water were acquired for visualisation and electron density verification. Characterisation of gel-water at 0 T was compared to Gammex-RMI solid water, using MagicPlate-512 (M512) and RMI Attix chamber; this included percentage depth dose, tissue-phantom ratio (TPR 20/10 ), tissue-maximum ratio (TMR), profiles, output factors, and a gamma analysis to investigate field penumbral differences. MR images of a non-powered detector in gel-water demonstrated detector visualisation. The CT-determined gel-water electron density agreed with the calculated value of 1.01. Gel-water depth dose data demonstrated a maximum deviation of 0.7% from solid water for M512 and 2.4% for the Attix chamber, and by 2.1% for TPR 20/10 and 1.0% for TMR. FWHM and output factor differences between materials were ≤0.3 and ≤1.4%. M512 data passed gamma analysis with 100% within 2%, 2 mm tolerance for multileaf collimator defined fields. Gel-water was shown to be tissue-equivalent for dosimetry and a feasible option to replace solid water.

  19. Patient-directed Internet-based Medical Image Exchange: Experience from an Initial Multicenter Implementation.

    Science.gov (United States)

    Greco, Giampaolo; Patel, Anand S; Lewis, Sara C; Shi, Wei; Rasul, Rehana; Torosyan, Mary; Erickson, Bradley J; Hiremath, Atheeth; Moskowitz, Alan J; Tellis, Wyatt M; Siegel, Eliot L; Arenson, Ronald L; Mendelson, David S

    2016-02-01

    Inefficient transfer of personal health records among providers negatively impacts quality of health care and increases cost. This multicenter study evaluates the implementation of the first Internet-based image-sharing system that gives patients ownership and control of their imaging exams, including assessment of patient satisfaction. Patients receiving any medical imaging exams in four academic centers were eligible to have images uploaded into an online, Internet-based personal health record. Satisfaction surveys were provided during recruitment with questions on ease of use, privacy and security, and timeliness of access to images. Responses were rated on a five-point scale and compared using logistic regression and McNemar's test. A total of 2562 patients enrolled from July 2012 to August 2013. The median number of imaging exams uploaded per patient was 5. Most commonly, exams were plain X-rays (34.7%), computed tomography (25.7%), and magnetic resonance imaging (16.1%). Of 502 (19.6%) patient surveys returned, 448 indicated the method of image sharing (Internet, compact discs [CDs], both, other). Nearly all patients (96.5%) responded favorably to having direct access to images, and 78% reported viewing their medical images independently. There was no difference between Internet and CD users in satisfaction with privacy and security and timeliness of access to medical images. A greater percentage of Internet users compared to CD users reported access without difficulty (88.3% vs. 77.5%, P Internet-based image-sharing system is feasible and surpasses the use of CDs with respect to accessibility of imaging exams while generating similar satisfaction with respect to privacy. Copyright © 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  20. Initiation process of a thrust fault revealed by analog experiments

    Science.gov (United States)

    Yamada, Yasuhiro; Dotare, Tatsuya; Adam, Juergen; Hori, Takane; Sakaguchi, Hide

    2016-04-01

    We conducted 2D (cross-sectional) analog experiments with dry sand using a high resolution digital image correlation (DIC) technique to reveal initiation process of a thrust fault in detail, and identified a number of "weak shear bands" and minor uplift prior to the thrust initiation. The observations suggest that the process can be divided into three stages. Stage 1: characterized by a series of abrupt and short-lived weak shear bands at the location where the thrust will be generated later. Before initiation of the fault, the area to be the hanging wall starts to uplift. Stage 2: defined by the generation of the new thrust and its active displacement. The location of the new thrust seems to be constrained by its associated back-thrust, produced at the foot of the surface slope (by the previous thrust). The activity of the previous thrust turns to zero once the new thrust is generated, but the timing of these two events is not the same. Stage 3: characterized by a constant displacement along the (new) thrust. Similar minor shear bands can be seen in the toe area of the Nankai accretionary prism, SW Japan and we can correlate the along-strike variations in seismic profiles to the model results that show the characteristic features in each thrust development stage.

  1. Susceptibility weighted imaging (SWI) of the kidney at 3 T. Initial results

    International Nuclear Information System (INIS)

    Mie, Moritz B.; Zoellner, Frank G.; Heilmann, Melanie; Schad, Lothar R.; Nissen, Johanna C.; Schoenberg, Stefan O.; Michaely, Henrik J.

    2010-01-01

    Susceptibility weighted imaging provides diagnostic information in strokes, hemorrhages, and cerebral tumors and has proven to be a valuable tool in imaging venous vessels in the cerebrum. The SWI principle is based on the weighting of T 2 * weighted magnitude images with a phase mask, therewith improving image contrast of veins or neighbouring structures of different susceptibility, in general. T 2 * weighted MRI is already used for assessment of kidney function. In this paper, the feasibility of SWI on kidneys was investigated. Translation of SWI from the brain to the kidneys comes along with two main challenges: (i) organ motion due to breathing and (ii) a higher oxygenation level of renal veins compared to the brain. To handle these problems, the acquisition time has been cut down to allow for breath-hold examinations, and different post-processing methods including a new phase mask were investigated to visualize renal veins. Results showed that by a new post-processing strategy SWI contrast was enhanced on average by a factor of 1.33 compared to the standard phase mask. In summary, initial experiences of SWI on the kidneys demonstrated the feasibility. However, further technical developments have to be performed to make this technology applicable in clinical abdominal MRI. (orig.)

  2. High spatial resolution whole-body MR angiography featuring parallel imaging: initial experience

    International Nuclear Information System (INIS)

    Quick, H.H.; Vogt, F.M.; Madewald, S.; Herborn, C.U.; Bosk, S.; Goehde, S.; Debatin, J.F.; Ladd, M.E.

    2004-01-01

    Materials and methods: whole-body multi-station MRA was performed with a rolling table platform (AngioSURF) on 5 volunteers in two imaging series: 1) standard imaging protocol, 2) modified high-resolution protocol employing PAT using the generalized autocalibrating partially parallel acquisitions (GRAPPA) algorithm with an acceleration factor of 3. For an intra-individual comparison of the two MR examinations, the arterial vasculature was divided into 30 segments. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated for all 30 arterial segments of each subject. Vessel segment depiction was qualitatively assessed applying a 5-point scale to each of the segments. Image reconstruction times were recorded for the standard as well as the PAT protocol. Results: compared to the standard protocol, PAT allowed for increased spatial resolution through a 3-fold reduction in mean voxel size for each of the 5 stations. Mean SNR and CNR values over all specified vessel segments decreased by a factor of 1.58 and 1.56, respectively. Despite the reduced SNR and CNR, the depiction of all specified vessel segments increased in PAT images, reflecting the increased spatial resolution. Qualitative comparison of standard and PAT images showed an increase in vessel segment conspicuity with more detailed depiction of intramuscular arterial branches in all volunteers. The time for image data reconstruction of all 5 stations was significantly increased from about 10 minutes to 40 minutes when using the PAT acquisition. (orig.) [de

  3. Positron emission tomography/magnetic resonance imaging (PET/MRI: An update and initial experience at HC-FMUSP

    Directory of Open Access Journals (Sweden)

    Marcelo A. Queiroz

    Full Text Available Summary The new technology of PET/MRI is a prototype of hybrid imaging, allowing for the combination of molecular data from PET scanning and morphofunctional information derived from MRI scanning. Recent advances regarding the technical aspects of this device, especially after the development of MRI-compatible silicon photomultipliers of PET, permitted an increase in the diagnostic performance of PET/MRI translated into dose reduction and higher imaging quality. Among several clinical applications, PET/MRI gains ground initially in oncology, where MRI per se plays an essential role in the assessment of primary tumors (which is limited in the case of PET/CT, including prostate, rectal and gynecological tumors. On the other hand, the evaluation of the lungs remains an enigma although new MRI sequences are being designed to overcome this. More clinical indications of PET/MRI are seen in the fields of neurology, cardiology and inflammatory processes, and the use of PET/MRI also opens perspectives for pediatric populations as it involves very low radiation exposure. Our review aimed to highlight the current indications of PET/MRI and discuss the challenges and perspectives of PET/MRI at HC-FMUSP.

  4. Initial Educational Experiences of Tertiary Students. LSAY Briefing Number 14

    Science.gov (United States)

    Hillman, Kylie

    2008-01-01

    This "Briefing" presents information about the initial tertiary education experiences, such as satisfaction with aspects of student life and changes to initial enrolments, of two groups of young people, based on two recent Longitudinal Surveys of Australian Youth (LSAY) research reports. One study focused on the first year experiences of…

  5. Portable Imaging Polarimeter and Imaging Experiments; TOPICAL

    International Nuclear Information System (INIS)

    PHIPPS, GARY S.; KEMME, SHANALYN A.; SWEATT, WILLIAM C.; DESCOUR, M.R.; GARCIA, J.P.; DERENIAK, E.L.

    1999-01-01

    Polarimetry is the method of recording the state of polarization of light. Imaging polarimetry extends this method to recording the spatially resolved state of polarization within a scene. Imaging-polarimetry data have the potential to improve the detection of manmade objects in natural backgrounds. We have constructed a midwave infrared complete imaging polarimeter consisting of a fixed wire-grid polarizer and rotating form-birefringent retarder. The retardance and the orientation angles of the retarder were optimized to minimize the sensitivity of the instrument to noise in the measurements. The optimal retardance was found to be 132(degree) rather than the typical 90(degree). The complete imaging polarimeter utilized a liquid-nitrogen cooled PtSi camera. The fixed wire-grid polarizer was located at the cold stop inside the camera dewar. The complete imaging polarimeter was operated in the 4.42-5(micro)m spectral range. A series of imaging experiments was performed using as targets a surface of water, an automobile, and an aircraft. Further analysis of the polarization measurements revealed that in all three cases the magnitude of circular polarization was comparable to the noise in the calculated Stokes-vector components

  6. X-ray imaging and 3D reconstruction of in-flight exploding foil initiator flyers

    Energy Technology Data Exchange (ETDEWEB)

    Willey, T. M., E-mail: willey1@llnl.gov; Champley, K., E-mail: champley1@llnl.gov; Hodgin, R.; Lauderbach, L.; Bagge-Hansen, M.; May, C.; Buuren, T. van [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Sanchez, N.; Jensen, B. J. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Iverson, A. [National Security Technologies, LLC, Las Vegas, Nevada 89193 (United States)

    2016-06-21

    Exploding foil initiators (EFIs), also known as slapper initiators or detonators, offer clear safety and timing advantages over other means of initiating detonation in high explosives. This work outlines a new capability for imaging and reconstructing three-dimensional images of operating EFIs. Flyer size and intended velocity were chosen based on parameters of the imaging system. The EFI metal plasma and plastic flyer traveling at 2.5 km/s were imaged with short ∼80 ps pulses spaced 153.4 ns apart. A four-camera system acquired 4 images from successive x-ray pulses from each shot. The first frame was prior to bridge burst, the 2nd images the flyer about 0.16 mm above the surface but edges of the foil and/or flyer are still attached to the substrate. The 3rd frame captures the flyer in flight, while the 4th shows a completely detached flyer in a position that is typically beyond where slappers strike initiating explosives. Multiple acquisitions at different incident angles and advanced computed tomography reconstruction algorithms were used to produce a 3-dimensional image of the flyer at 0.16 and 0.53 mm above the surface. Both the x-ray images and the 3D reconstruction show a strong anisotropy in the shape of the flyer and underlying foil parallel vs. perpendicular to the initiating current and electrical contacts. These results provide detailed flyer morphology during the operation of the EFI.

  7. Initial deuterium pellet experiments on FTU

    International Nuclear Information System (INIS)

    Snipes, J.A.

    1993-01-01

    Initial experiments have been performed with the Single Pellet INjector (SPIN) on FTU. SPIN is a two-stage cryogenic deuterium pellet injector capable of injection,a pellets with velocities up to 2.5 km/s. The nominal pellet mass for these experiments was approximately 1 x 10 20 atoms. These initial pellet experiments concentrated on studying pellet penetration under a variety of plasma conditions to compare with code predictions and to examine toroidal particle transport. The principal diagnostics used were two fast (∼1 μsec) photomultiplier tubes at nearly opposite toroidal locations with H α (D α ) interference filters (λ = 656 nm), a microwave cavity for pellet mass and velocity, a vertical array of soft x ray diodes without filters looking down onto the pellet, a DCN interferometer for electron density profiles, and a Michelson ECE system for electron temperature profiles. The time integral of the absolutely calibrated fast H α signal appears to give reasonable agreement with the expected pellet mass. Toroidal transport of deuterium ions from the pellet to nearly the opposite side of the tokamak agrees with calculated thermal deuterium velocities near the plasma edge. Comparison of the experimental results with code calculations using the Neutral Gas Shielding model show good agreement for the post-pellet electron temperature and density profiles and the H α profiles in some cases. Calculated penetration distances agree within 20%

  8. Rapid musculoskeletal magnetic resonance imaging using integrated parallel acquisition techniques (IPAT) - Initial experiences

    International Nuclear Information System (INIS)

    Romaneehsen, B.; Oberholzer, K.; Kreitner, K.-F.; Mueller, L.P.

    2003-01-01

    Purpose: To investigate the feasibility of using multiple receiver coil elements for time saving integrated parallel imaging techniques (iPAT) in traumatic musculoskeletal disorders. Material and methods: 6 patients with traumatic derangements of the knee, ankle and hip underwent MR imaging at 1.5 T. For signal detection of the knee and ankle, we used a 6-channel body array coil that was placed around the joints, for hip imaging two 4-channel body array coils and two elements of the spine array coil were combined for signal detection. All patients were investigated with a standard imaging protocol that mainly consisted of different turbo spin-echo sequences (PD-, T 2 -weighted TSE with and without fat suppression, STIR). All sequences were repeated with an integrated parallel acquisition technique (iPAT) using a modified sensitivity encoding (mSENSE) technique with an acceleration factor of 2. Overall image quality was subjectively assessed using a five-point scale as well as the ability for detection of pathologic findings. Results: Regarding overall image quality, there were no significant differences between standard imaging and imaging using mSENSE. All pathologies (occult fracture, meniscal tear, torn and interpositioned Hoffa's cleft, cartilage damage) were detected by both techniques. iPAT led to a 48% reduction of acquisition time compared with standard technique. Additionally, time savings with iPAT led to a decrease of pain-induced motion artifacts in two cases. Conclusion: In times of increasing cost pressure, iPAT using multiple coil elements seems to be an efficient and economic tool for fast musculoskeletal imaging with diagnostic performance comparable to conventional techniques. (orig.) [de

  9. Patients' Experiences of Performing Self-care of Stomas in the Initial Postoperative Period.

    Science.gov (United States)

    Lim, Siew Hoon; Chan, Sally Wai Chi; He, Hong-Gu

    2015-01-01

    With the loss of an important bodily function and the distortion in body image, a stoma patient experiences physical, psychological, and social changes. With limited current studies exploring experiences of patients in the management of their stoma, there is a need to explore their experiences, their needs, and factors that influence their self-management. The aim of this study was to investigate patients' experiences of performing self-care of stomas in the initial postoperative period. This study adopted a descriptive qualitative approach from the interpretive paradigm. Semistructured interviews were conducted with 12 patients 1 month postoperatively in a colorectal ward in a hospital in Singapore. Thematic analysis was applied to the interview data. Five themes were identified: process of acceptance and self-management of stoma, physical limitations, psychological reactions, social support, and need for timely and sufficient stoma preparation and education. This study highlights the importance of health professionals' role in helping patients adjust preoperatively and postoperatively and accept the presence of a stoma. Health professionals need to be aware of the physical, psychological, and social impact of stoma on patients in the initial 30-day postoperative period. Research findings informed the type and level of assistance and support to be offered to patients by nurses and the importance of encouraging patients to be involved in stoma care at an early stage, which will ultimately contribute to effective and independent self-management. Patients can be prepared preoperatively to reduce the psychological and social impact of stoma after creation of their stoma.

  10. Reconstruction of initial pressure from limited view photoacoustic images using deep learning

    Science.gov (United States)

    Waibel, Dominik; Gröhl, Janek; Isensee, Fabian; Kirchner, Thomas; Maier-Hein, Klaus; Maier-Hein, Lena

    2018-02-01

    Quantification of tissue properties with photoacoustic (PA) imaging typically requires a highly accurate representation of the initial pressure distribution in tissue. Almost all PA scanners reconstruct the PA image only from a partial scan of the emitted sound waves. Especially handheld devices, which have become increasingly popular due to their versatility and ease of use, only provide limited view data because of their geometry. Owing to such limitations in hardware as well as to the acoustic attenuation in tissue, state-of-the-art reconstruction methods deliver only approximations of the initial pressure distribution. To overcome the limited view problem, we present a machine learning-based approach to the reconstruction of initial pressure from limited view PA data. Our method involves a fully convolutional deep neural network based on a U-Net-like architecture with pixel-wise regression loss on the acquired PA images. It is trained and validated on in silico data generated with Monte Carlo simulations. In an initial study we found an increase in accuracy over the state-of-the-art when reconstructing simulated linear-array scans of blood vessels.

  11. Beyond where it started: a look at the "Healing Images" experience.

    Science.gov (United States)

    Goodsmith, Lauren

    2007-01-01

    In March 2004, the Baltimore-based nonprofit organization Advocates for Survivors of Torture and Trauma (ASTT) initiated a photography-based therapeutic programme for clients. Developed by a professional photographer/teacher in collaboration with a psychologist, the programme has the goal of enabling clients to engage in creative self-exploration within a supportive, group setting. Since its inception, thirty survivors of conflict-related trauma and torture from five different countries have taken part in the programme, known as "Healing Images", using digital cameras to gather individually-chosen images that are subsequently shared and discussed within the group. These images include depictions of the natural and manmade environments in which clients find themselves; people, places and objects that offer comfort; and self-portraits that reflect the reality of the life of a refugee in the United States. This description of the "Healing Images" programme is based on comments gathered through discussion with participants and through interviews. Additional information was gathered from observation of early workshop sessions, review of numerous client photographs and captions, and pertinent organizational materials. A fundamental benefit of the programme was that it offered a mutually supportive group environment that diminished clients' feelings of psychological and physical isolation. Participants gained deep satisfaction from learning the technical skills related to use of the cameras, from the empowering experience of framing and creating specific images, and from exploring the personal significance of these images. Programme activities sparked a process of self-expression that participants valued on the level of personal discovery and growth. Some clients also welcomed opportunities to share their work publicly, as a means of raising awareness of the experience of survivors.

  12. Ultrasoft x-ray imaging system for the National Spherical Torus Experiment

    Science.gov (United States)

    Stutman, D.; Finkenthal, M.; Soukhanovskii, V.; May, M. J.; Moos, H. W.; Kaita, R.

    1999-01-01

    A spectrally resolved ultrasoft x-ray imaging system, consisting of arrays of high resolution (the National Spherical Torus Experiment. Initially, three poloidal arrays of diodes filtered for C 1s-np emission will be implemented for fast tomographic imaging of the colder start-up plasmas. Later on, mirrors tuned to the C Lyα emission will be added in order to enable the arrays to "see" the periphery through the hot core and to study magnetohydrodynamic activity and impurity transport in this region. We also discuss possible core diagnostics, based on tomographic imaging of the Lyα emission from the plume of recombined, low Z impurity ions left by neutral beams or fueling pellets. The arrays can also be used for radiated power measurements and to map the distribution of high Z impurities injected for transport studies. The performance of the proposed system is illustrated with results from test channels on the CDX-U spherical torus at Princeton Plasma Physics Laboratory.

  13. Percutaneous MR-guided cryoablation of prostate cancer: initial experience

    International Nuclear Information System (INIS)

    Gangi, Afshin; Tsoumakidou, Georgia; Abdelli, Omar; Buy, Xavier; Mathelin, Michel de; Jacqmin, Didier; Lang, Herve

    2012-01-01

    We report our initial experience and the technical feasibility of transperineal prostate cryoablation under MR guidance. Percutaneous MR-guided cryoablation was performed in 11 patients with prostatic adenocarcinoma contraindicated for surgery (mean age: 72 years, mean Gleason score: 6.45, mean prostate-specific antigen (PSA): 6.21 ng/ml, T1-2c/N0/M0, mean: prostate volume 36.44 ml). Free-hand probe positioning was performed under real-time MR imaging. Four to seven cryoprobes were inserted into the prostate, depending on gland volume. The ice ball was monitored using real-time and high-resolution BLADE multi-planar imaging. Patients were followed at 1, 3, 6, 9 and 12 months after the procedure with serum PSA level and post-ablation MRI. Prostate cryoablation was technically feasible in 10/11 patients. The ice ball was clearly and sharply visualised in all cases as a signal-void area. Mean ice-ball volume was 53.3 ml. Mean follow-up was 15 months (range: 1-25). Mean PSA nadir was 0.33 ng/ml (range: 0.02-0.94 ng/ml). Mean hospitalisation was 5 days (range: 3-13). Complications included a urethro-rectal fistula, urinary infection, transient dysuria and scrotal pain. MR-guided prostate cryoablation is feasible and promising, with excellent monitoring of the ice ball. Future perspectives could include the use of MR guidance for focal prostate cancer cryotherapy. (orig.)

  14. Percutaneous MR-guided cryoablation of prostate cancer: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Gangi, Afshin; Tsoumakidou, Georgia; Abdelli, Omar; Buy, Xavier [University Hospital of Strasbourg, Department of Interventional Radiology, Strasbourg (France); Mathelin, Michel de [University of Strasbourg, Lsiit, Strasbourg (France); Jacqmin, Didier; Lang, Herve [University Hospital of Strasbourg, Department of Urology, Strasbourg (France)

    2012-08-15

    We report our initial experience and the technical feasibility of transperineal prostate cryoablation under MR guidance. Percutaneous MR-guided cryoablation was performed in 11 patients with prostatic adenocarcinoma contraindicated for surgery (mean age: 72 years, mean Gleason score: 6.45, mean prostate-specific antigen (PSA): 6.21 ng/ml, T1-2c/N0/M0, mean: prostate volume 36.44 ml). Free-hand probe positioning was performed under real-time MR imaging. Four to seven cryoprobes were inserted into the prostate, depending on gland volume. The ice ball was monitored using real-time and high-resolution BLADE multi-planar imaging. Patients were followed at 1, 3, 6, 9 and 12 months after the procedure with serum PSA level and post-ablation MRI. Prostate cryoablation was technically feasible in 10/11 patients. The ice ball was clearly and sharply visualised in all cases as a signal-void area. Mean ice-ball volume was 53.3 ml. Mean follow-up was 15 months (range: 1-25). Mean PSA nadir was 0.33 ng/ml (range: 0.02-0.94 ng/ml). Mean hospitalisation was 5 days (range: 3-13). Complications included a urethro-rectal fistula, urinary infection, transient dysuria and scrotal pain. MR-guided prostate cryoablation is feasible and promising, with excellent monitoring of the ice ball. Future perspectives could include the use of MR guidance for focal prostate cancer cryotherapy. (orig.)

  15. MR imaging near metallic implants using MAVRIC SL: initial clinical experience at 3T.

    Science.gov (United States)

    Gutierrez, Luis B; Do, Bao H; Gold, Garry E; Hargreaves, Brian A; Koch, Kevin M; Worters, Pauline W; Stevens, Kathryn J

    2015-03-01

    To compare the effectiveness of multiacquisition with variable resonance image combination selective (MAVRIC SL) with conventional two-dimensional fast spin-echo (2D-FSE) magnetic resonance (MR) techniques at 3T in imaging patients with a variety of metallic implants. Twenty-one 3T MR studies were obtained in 19 patients with different types of metal implants. Paired MAVRIC SL and 2D-FSE sequences were reviewed by two radiologists and compared for in-plane and through-plane metal artifact, visualization of the bone implant interface and surrounding soft tissues, blurring, and overall image quality using a two-tailed Wilcoxon signed rank test. The area of artifact on paired images was measured and compared using a paired Wilcoxon signed rank test. Changes in patient management resulting from MAVRIC SL imaging were documented. Significantly less in-plane and through-plane artifact was seen with MAVRIC SL, with improved visualization of the bone-implant interface and surrounding soft tissues, and superior overall image quality (P = .0001). Increased blurring was seen with MAVRIC SL (P = .0016). MAVRIC SL significantly decreased the image artifact compared to 2D-FSE (P = .0001). Inclusion of MAVRIC SL to the imaging protocol determined the need for surgery or type of surgery in five patients and ruled out the need for surgery in 13 patients. In three patients, the area of interest was well seen on both MAVRIC SL and 2D-FSE images, so the addition of MAVRIC had no effect on patient management. Imaging around metal implants with MAVRIC SL at 3T significantly improved image quality and decreased image artifact compared to conventional 2D-FSE imaging techniques and directly impacted patient management. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  16. Women’s experiences and preferences regarding breast imaging after completing breast cancer treatment

    Directory of Open Access Journals (Sweden)

    Brandzel S

    2017-02-01

    Full Text Available Susan Brandzel,1 Dori E Rosenberg,1 Dianne Johnson,1 Mary Bush,1 Karla Kerlikowske,2–5 Tracy Onega,6,7 Louise Henderson,8 Larissa Nekhlyudov,9,10 Wendy DeMartini,11 Karen J Wernli1 1Group Health Research Institute, Group Health Cooperative, Seattle, WA, 2Department of Medicine, 3Department of Epidemiology, 4Department of Biostatistics, 5Department of Veterans Affairs, University of California, San Francisco, San Francisco, CA, 6Department of Biomedical Data Science, 7Department of Epidemiology, Norris Cotton Cancer Center, Geisel School of Medicine at Dartmouth, Lebanon, NH, 8Department of Radiology, University of North Carolina, Chapel Hill, NC, 9Department of Population Medicine, Harvard Medical School, 10Department of Medicine, Brigham and Women’s Hospital, Boston, MA, 11Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA Background: After treatment for breast cancer, most women receive an annual surveillance mammography to look for subsequent breast cancers. Supplemental breast MRI is sometimes used in addition to mammography despite the lack of clinical evidence for it. Breast imaging after cancer treatment is an emotionally charged experience, an important part of survivorship care, and a topic about which limited patient information exists. We assessed women’s experiences and preferences about breast cancer surveillance imaging with the goal of determining where gaps in care and knowledge could be filled. Participants and methods: We conducted six focus groups with a convenience sample of 41 women in California, North Carolina, and New Hampshire (USA. Participants were aged 38–75 years, had experienced stage 0–III breast cancer within the previous 5 years, and had completed initial treatment. We used inductive thematic analysis to identify key themes from verbatim transcripts. Results: Women reported various types and frequencies of surveillance imaging and a range of surveillance imaging

  17. The clinical utility of reduced-distortion readout-segmented echo-planar imaging in the head and neck region: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Koyasu, Sho; Iima, Mami; Umeoka, Shigeaki; Morisawa, Nobuko; Togashi, Kaori [Kyoto University, Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Porter, David A. [Siemens AG, MED MR PLM AW Neurology, Allee am Roethelheimpark 2, Erlangen (Germany); Ito, Juichi [Kyoto University, Department of Otolaryngology, Head and Neck Surgery, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Le Bihan, Denis [Kyoto University, Human Brain Research Center, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Neurospin, CEA-Saclay Center, Gif-sur-Yvette Cedex (France)

    2014-12-15

    To evaluate whether readout-segmented echo-planar imaging (RS-EPI) diffusion weighted image (DWI) can diminish image distortion in the head and neck area, compared with single-shot (SS)-EPI DWI. We conducted phantom and patient studies using 3 T magnetic resonance imaging (MRI) with a 16-channel coil. For the phantom study, we evaluated distortion and signal homogeneity in gel phantoms. For the patient study, 29 consecutive patients with clinically suspicious parotid lesions were prospectively enrolled. RS-EPI and SS-EPI DWI were evaluated by two independent readers for identification of organ/lesion and distortion, using semiquantitative scales and quantitative scores. Apparent diffusion coefficient (ADC) values and contrast-noise ratios of parotid tumours (if present; n = 15) were also compared. The phantom experiments showed that RS-EPI provided less distorted and more homogeneous ADC maps than SS-EPI. In the patient study, RS-EPI was found to provide significantly less distortion in almost all organs/lesions (p < 0.05), according to both semiquantitative scales and quantitative scores. There was no significant difference in ADC values and contrast-noise ratios between the two DWI techniques. The distortion in DWI was significantly reduced with RS-EPI in both phantom and patient studies. The RS-EPI technique provided more homogenous images than SS-EPI, and can potentially offer higher image quality in the head and neck area. (orig.)

  18. Initial experience in hybrid PET-MRI for evaluation of refractory focal onset epilepsy.

    Science.gov (United States)

    Shin, Hae W; Jewells, Valerie; Sheikh, Arif; Zhang, Jingwen; Zhu, Hongtu; An, Hongyu; Gao, Wei; Shen, Dinggang; Hadar, Eldad; Lin, Weili

    2015-09-01

    We aim to evaluate the utility/improved accuracy of hybrid PET/MR compared to current practice separate 3T MRI and PET-CT imaging for localization of seizure foci. In a pilot study, twenty-nine patients undergoing epilepsy surgery evaluation were imaged using PET/MR. This subject group had 29 previous clinical 3T MRI as well as 12 PET-CT studies. Prior clinical PET and MR images were read sequentially while the hybrid PET/MR was concurrently read. The median interval between hybrid PET/MR and prior imaging studies was 5 months (range 1-77 months). In 24 patients, there was no change in the read between the clinical exams and hybrid PET/MR while new anatomical or functional lesions were identified by hybrid PET/MR in 5 patients without significant clinical change. Four new anatomical MR lesions were seen with concordant PET findings. The remaining patient revealed a new abnormal PET lesion without an MR abnormality. All new PET/MR lesions were clinically significant with concordant EEG and/or SPECT results as potential epileptic foci. Our initial hybrid PET-MRI experience increased diagnostic yields for detection of potential epileptic lesions. This may be due to the unique advantage of improved co-registration and simultaneous review of both structural and functional data. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  19. Initial Results from Coaxial Helicity Injection Experiments in NSTX

    International Nuclear Information System (INIS)

    Raman, R.; Jarboe, T.R.; Mueller, D.; Schaffer, M.J.; Maqueda, R.; Nelson, B.A.; Sabbagh, S.; Bell, M.; Ewig, R.; Fredrickson, E.; Gates, D.; Hosea, J.; Ji, H.; Kaita, R.; Kaye, S.M.; Kugel, H.; Maingi, R.; Menard, J.; Ono, M.; Orvis, D.; Paolette, F.; Paul, S.; Peng, M.; Skinner, C.H.; Wilgen, W.; Zweben, S.

    2001-01-01

    Coaxial Helicity Injection (CHI) has been investigated on the National Spherical Torus Experiment (NSTX). Initial experiments produced 130 kA of toroidal current without the use of the central solenoid. The corresponding injector current was 20 kA. Discharges with pulse lengths up to 130 ms have been produced

  20. REMOTE SENSING IMAGE QUALITY ASSESSMENT EXPERIMENT WITH POST-PROCESSING

    Directory of Open Access Journals (Sweden)

    W. Jiang

    2018-04-01

    Full Text Available This paper briefly describes the post-processing influence assessment experiment, the experiment includes three steps: the physical simulation, image processing, and image quality assessment. The physical simulation models sampled imaging system in laboratory, the imaging system parameters are tested, the digital image serving as image processing input are produced by this imaging system with the same imaging system parameters. The gathered optical sampled images with the tested imaging parameters are processed by 3 digital image processes, including calibration pre-processing, lossy compression with different compression ratio and image post-processing with different core. Image quality assessment method used is just noticeable difference (JND subject assessment based on ISO20462, through subject assessment of the gathered and processing images, the influence of different imaging parameters and post-processing to image quality can be found. The six JND subject assessment experimental data can be validated each other. Main conclusions include: image post-processing can improve image quality; image post-processing can improve image quality even with lossy compression, image quality with higher compression ratio improves less than lower ratio; with our image post-processing method, image quality is better, when camera MTF being within a small range.

  1. 3D dynamic pituitary MR imaging with CAIPIRINHA: Initial experience and comparison with 2D dynamic MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fushimi, Yasutaka, E-mail: yfushimi@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Okada, Tomohisa; Kanagaki, Mitsunori; Yamamoto, Akira; Kanda, Yumiko; Sakamoto, Ryo [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Hojo, Masato; Takahashi, Jun C.; Miyamoto, Susumu [Department of Neurosurgery, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan)

    2014-10-15

    Objectives: To evaluate the validity of 3D dynamic pituitary MR imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA), with special emphasis on demarcation of pituitary posterior lobe and stalk. Methods: Participants comprised 32 patients who underwent dynamic pituitary MR imaging due to pituitary or parasellar lesions. 3D dynamic MR with CAIPIRINHA was performed at 3 T with 20-s-interval, precontrast, 1st to 5th dynamic images. Normalized values and enhanced ratios (dynamic postcontrast image values divided by precontrast ones) were compared between 3D and 2D dynamic MR imaging for patients with visual identification of posterior lobe and stalk. Results: In 3D, stalk was identified in 29 patients and unidentified in 3, and posterior lobe was identified in 28 and unidentified in 4. In 2D, stalk was identified in 26 patients and unidentified in 6 patients, and posterior lobe was identified in 15 and unidentified in 17. Normalized values of pituitary posterior lobe and stalk were higher in 3D than 2D (P < 0.001). No significant difference in enhancement ratio was seen between 3D and 2D. Conclusions: 3D dynamic pituitary MR provided better identification and higher normalized values of pituitary posterior lobe and stalk than 2D.

  2. Magnetohydrodynamic simulation of solid-deuterium-initiated Z-pinch experiments

    International Nuclear Information System (INIS)

    Sheehey, P.T.

    1994-02-01

    Solid-deuterium-initiated Z-pinch experiments are numerically simulated using a two-dimensional resistive magnetohydrodynamic model, which includes many important experimental details, such as ''cold-start'' initial conditions, thermal conduction, radiative energy loss, actual discharge current vs. time, and grids of sufficient size and resolution to allow realistic development of the plasma. The alternating-direction-implicit numerical technique used meets the substantial demands presented by such a computational task. Simulations of fiber-initiated experiments show that when the fiber becomes fully ionized rapidly developing m=0 instabilities, which originated in the coronal plasma generated from the ablating fiber, drive intense non-uniform heating and rapid expansion of the plasma column. The possibility that inclusion of additional physical effects would improve stability is explored. Finite-Larmor-radius-ordered Hall and diamagnetic pressure terms in the magnetic field evolution equation, corresponding energy equation terms, and separate ion and electron energy equations are included; these do not change the basic results. Model diagnostics, such as shadowgrams and interferograms, generated from simulation results, are in good agreement with experiment. Two alternative experimental approaches are explored: high-current magnetic implosion of hollow cylindrical deuterium shells, and ''plasma-on-wire'' (POW) implosion of low-density plasma onto a central deuterium fiber. By minimizing instability problems, these techniques may allow attainment of higher temperatures and densities than possible with bare fiber-initiated Z-pinches. Conditions for significant D-D or D-T fusion neutron production may be realizable with these implosion-based approaches

  3. The impact of brand image on customer experience – Company X

    OpenAIRE

    Siitonen, Hannes

    2017-01-01

    The aim of this thesis was to find out what kind of relationship there is between brand image and customer experience, and how the brand image affects to customer experience. The aim was also to define the company’s brand image and customer experience among the target groups, and what factors do affect to them. In addition, this thesis aimed to produce valuable information for the company about their brand image, customer experience, customer behaviour and customer satisfaction, followed by i...

  4. Rapid musculoskeletal magnetic resonance imaging using integrated parallel acquisition techniques (IPAT) - Initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Romaneehsen, B.; Oberholzer, K.; Kreitner, K.-F. [Johannes Gutenberg-Univ. Mainz (Germany). Klinik und Poliklinik fuer Radiologie; Mueller, L.P. [Johannes Gutenberg-Univ. Mainz (Germany). Klinik und Poliklinik fuer Unfallchirurgie

    2003-09-01

    Purpose: To investigate the feasibility of using multiple receiver coil elements for time saving integrated parallel imaging techniques (iPAT) in traumatic musculoskeletal disorders. Material and methods: 6 patients with traumatic derangements of the knee, ankle and hip underwent MR imaging at 1.5 T. For signal detection of the knee and ankle, we used a 6-channel body array coil that was placed around the joints, for hip imaging two 4-channel body array coils and two elements of the spine array coil were combined for signal detection. All patients were investigated with a standard imaging protocol that mainly consisted of different turbo spin-echo sequences (PD-, T{sub 2}-weighted TSE with and without fat suppression, STIR). All sequences were repeated with an integrated parallel acquisition technique (iPAT) using a modified sensitivity encoding (mSENSE) technique with an acceleration factor of 2. Overall image quality was subjectively assessed using a five-point scale as well as the ability for detection of pathologic findings. Results: Regarding overall image quality, there were no significant differences between standard imaging and imaging using mSENSE. All pathologies (occult fracture, meniscal tear, torn and interpositioned Hoffa's cleft, cartilage damage) were detected by both techniques. iPAT led to a 48% reduction of acquisition time compared with standard technique. Additionally, time savings with iPAT led to a decrease of pain-induced motion artifacts in two cases. Conclusion: In times of increasing cost pressure, iPAT using multiple coil elements seems to be an efficient and economic tool for fast musculoskeletal imaging with diagnostic performance comparable to conventional techniques. (orig.) [German] Ziel: Einsatz integrierter paralleler Akquisitionstechniken (iPAT) zur Verkuerzung der Untersuchungszeit bei muskuloskelettalen Verletzungen. Material und Methoden: 6 Patienten mit einem Knie, Sprunggelenks- oder Huefttrauma wurden bei 1,5 T

  5. Cardiac cine imaging at 3 Tesla: initial experience with a 32-element body-array coil.

    Science.gov (United States)

    Fenchel, Michael; Deshpande, Vibhas S; Nael, Kambiz; Finn, J Paul; Miller, Stephan; Ruehm, Stefan; Laub, Gerhard

    2006-08-01

    We sought to assess the feasibility of cardiac cine imaging and evaluate image quality at 3 T using a body-array coil with 32 coil elements. Eight healthy volunteers (3 men; median age 29 years) were examined on a 3-T magnetic resonance scanner (Magnetom Trio, Siemens Medical Solutions) using a 32-element phased-array coil (prototype from In vivo Corp.). Gradient-recalled-echo (GRE) cine (GRAPPAx3), GRE cine with tagging lines, steady-state-free-precession (SSFP) cine (GRAPPAx3 and x4), and SSFP cine(TSENSEx4 andx6) images were acquired in short-axis and 4-chamber view. Reference images with identical scan parameters were acquired using the total-imaging-matrix (Tim) coil system with a total of 12 coil elements. Images were assessed by 2 observers in a consensus reading with regard to image quality, noise and presence of artifacts. Furthermore, signal-to-noise values were determined in phantom measurements. In phantom measurements signal-to-noise values were increased by 115-155% for the various cine sequences using the 32-element coil. Scoring of image quality yielded statistically significant increased image quality with the SSFP-GRAPPAx4, SSFP-TSENSEx4, and SSFP-TSENSEx6 sequence using the 32-element coil (P < 0.05). Similarly, scoring of image noise yielded a statistically significant lower noise rating with the SSFP-GRAPPAx4, GRE-GRAPPAx3, SSFP-TSENSEx4, and SSFP-TSENSEx6 sequence using the 32-element coil (P < 0.05). This study shows that cardiac cine imaging at 3 T using a 32-element body-array coil is feasible in healthy volunteers. Using a large number of coil elements with a favorable sensitivity profile supports faster image acquisition, with high diagnostic image quality even for high parallel imaging factors.

  6. A novel image toggle tool for comparison of serial mammograms: automatic density normalization and alignment-development of the tool and initial experience.

    Science.gov (United States)

    Honda, Satoshi; Tsunoda, Hiroko; Fukuda, Wataru; Saida, Yukihisa

    2014-12-01

    The purpose is to develop a new image toggle tool with automatic density normalization (ADN) and automatic alignment (AA) for comparing serial digital mammograms (DMGs). We developed an ADN and AA process to compare the images of serial DMGs. In image density normalization, a linear interpolation was applied by taking two points of high- and low-brightness areas. The alignment was calculated by determining the point of the greatest correlation while shifting the alignment between the current and prior images. These processes were performed on a PC with a 3.20-GHz Xeon processor and 8 GB of main memory. We selected 12 suspected breast cancer patients who had undergone screening DMGs in the past. Automatic processing was retrospectively performed on these images. Two radiologists subjectively evaluated them. The process of the developed algorithm took approximately 1 s per image. In our preliminary experience, two images could not be aligned approximately. When they were aligned, image toggling allowed detection of differences between examinations easily. We developed a new tool to facilitate comparative reading of DMGs on a mammography viewing system. Using this tool for toggling comparisons might improve the interpretation efficiency of serial DMGs.

  7. Paediatric magnetic resonance enteroclysis under general anaesthesia - initial experience

    International Nuclear Information System (INIS)

    Sadigh, Sophie; Chopra, Mark; Olsen, Oeystein E.; Watson, Tom A.; Sury, Michael R.; Shah, Neil

    2017-01-01

    MR enterography is the accepted imaging reference standard for small bowel assessment in inflammatory bowel disease. There is an increasing cohort of children with inflammatory bowel disease presenting at an early age (<5 years) with severe disease. Younger children present a technical challenge for enterography because of the need for sedation/general anaesthesia to allow image optimisation and the need for oral contrast to allow adequate luminal assessment. Through our experiences, MR enteroclysis under general anaesthesia has proven to be a successful imaging technique for the work-up of these patients. In this paper, we present our institutional practice for performing MR enteroclysis under general anaesthesia. (orig.)

  8. Paediatric magnetic resonance enteroclysis under general anaesthesia - initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Sadigh, Sophie; Chopra, Mark; Olsen, Oeystein E.; Watson, Tom A. [Great Ormond Street Hospital NHS Foundation Trust, Department of Paediatric Radiology, London (United Kingdom); Sury, Michael R. [Great Ormond Street Hospital NHS Foundation Trust, Department of Paediatric Anaesthetics, London (United Kingdom); Shah, Neil [Great Ormond Street Hospital NHS Foundation Trust, Department of Paediatric Gastroenterology, London (United Kingdom)

    2017-06-15

    MR enterography is the accepted imaging reference standard for small bowel assessment in inflammatory bowel disease. There is an increasing cohort of children with inflammatory bowel disease presenting at an early age (<5 years) with severe disease. Younger children present a technical challenge for enterography because of the need for sedation/general anaesthesia to allow image optimisation and the need for oral contrast to allow adequate luminal assessment. Through our experiences, MR enteroclysis under general anaesthesia has proven to be a successful imaging technique for the work-up of these patients. In this paper, we present our institutional practice for performing MR enteroclysis under general anaesthesia. (orig.)

  9. The experiences of employees participating in organisational corporate social responsibility initiatives

    Directory of Open Access Journals (Sweden)

    Gretha Cook

    2018-04-01

    Full Text Available Orientation: This article is about the experiences of employees who actively participate in organisational corporate social responsibility (CSR initiatives.   Research purpose: The general aim of this study was to explore the experiences of employees who participate in CSR initiatives within an organisation where a well-developed framework exists.   Motivation for the study: Whilst an emergent number of studies have considered the various dimensions of CSR initiatives, the focus appears to be on stakeholders such as the recipients of CSR, organisations, consumers and shareholders but not the perspective of the employees who actively participate in CSR initiatives.   Research design, approach and method: A qualitative research approach was employed with the intent of exploring the experiences of employees participating in organisational CSR initiatives. Data were collected and analysed from a purposive sample of 12 employees, by means of interactive qualitative analysis.   Main findings: The study revealed that the primary driver that motivates employees to participate in CSR is love. Love sparks a sense of compassion. Compassion, coupled with an enabling environment, stimulates generosity. By being generous, a feeling of hope and inspiration is induced in both the givers and receivers of generosity. A secondary outcome of generosity and hope and inspiration is bringing about change to others, and whilst going through this journey and making a difference in the lives of others, participants experience a progressive change within themselves. This change evokes a feeling of fulfilment, and ultimately a feeling of complete joy.   Contributions or value-add: This research complements existing CSR literature by focussing and reporting on the experiences of the employee as an important stakeholder.

  10. A factorial experiment on image quality and radiation dose

    International Nuclear Information System (INIS)

    Norrman, E.; Persliden, J.

    2005-01-01

    To find if factorial experiments can be used in the optimisation of diagnostic imaging, a factorial experiment was performed to investigate some of the factors that influence image quality, kerma area product (KAP) and effective dose (E). In a factorial experiment the factors are varied together instead of one at a time, making it possible to discover interactions between the factors as well as major effects. The factors studied were tube potential, tube loading, focus size and filtration. Each factor was set to two levels (low and high). The influence of the factors on the response variables (image quality, KAP and E) was studied using a direct digital detector. The major effects of each factor on the response variables were estimated as well as the interaction effects between factors. The image quality, KAP and E were mainly influenced by tube loading, tube potential and filtration. There were some active interactions, for example, between tube potential and filtration and between tube loading and filtration. The study shows that factorial experiments can be used to predict the influence of various parameters on image quality and radiation dose. (authors)

  11. SPECIAL ASPECTS OF INITIAL OPTICAL SCHEME SELECTION FOR DESIGN OF NON-IMAGING OPTICAL SYSTEMS

    Directory of Open Access Journals (Sweden)

    R. V. Anitropov

    2016-01-01

    Full Text Available Subject of Research. The research results, structural composition analysis and the parametric synthesis of the projected imaging and non-imaging optical systems were presented. We made an attempt to use the gained experience about imaging systems while designing non-imaging systems, by adapting the composition theory for the calculations of non-imaging systems. Several patterns were revealed, which provide a deeper understanding of the design process of non-imaging optical systems; measures of its optimization were proposed. Method. We investigated the applicability of the theory of composition and synthesis of non-imaging optical systems. The main provisions of the theory of composition are based on the division of all available optical elements in four types depending on their functionality, which corresponds to a modular design. Similar items were identified in non-imaging optical systems and adaptation of composition theory to their design became possible. Main Results. General design patterns of imaging and non-imaging optical systems were studied. Classification of systems, components, as well as technical and generic characteristics of imaging and non-imaging optical systems was determined. Search mechanism of the initial optical system by means of structural and parametric synthesis of non-imaging optical system was formalized. The basic elements were determined included in non-imaging systems and their classification by functionality was done. They were subdivided into basic, corrective, wide angle and high aperture ones. The rules for formation of these elements and their composition were determined: surface reflecting, refracting, spherical and nonspherical elements with total internal reflection. The foundations of composition theory for non-imaging optical systems were laid. The approbation of this method was carried out on the example of the illumination system calculation for surgical room. A 3D model of an illumination optical

  12. The Galileo Solid-State Imaging experiment

    Science.gov (United States)

    Belton, M.J.S.; Klaasen, K.P.; Clary, M.C.; Anderson, J.L.; Anger, C.D.; Carr, M.H.; Chapman, C.R.; Davies, M.E.; Greeley, R.; Anderson, D.; Bolef, L.K.; Townsend, T.E.; Greenberg, R.; Head, J. W.; Neukum, G.; Pilcher, C.B.; Veverka, J.; Gierasch, P.J.; Fanale, F.P.; Ingersoll, A.P.; Masursky, H.; Morrison, D.; Pollack, James B.

    1992-01-01

    The Solid State Imaging (SSI) experiment on the Galileo Orbiter spacecraft utilizes a high-resolution (1500 mm focal length) television camera with an 800 ?? 800 pixel virtual-phase, charge-coupled detector. It is designed to return images of Jupiter and its satellites that are characterized by a combination of sensitivity levels, spatial resolution, geometric fiedelity, and spectral range unmatched by imaging data obtained previously. The spectral range extends from approximately 375 to 1100 nm and only in the near ultra-violet region (??? 350 nm) is the spectral coverage reduced from previous missions. The camera is approximately 100 times more sensitive than those used in the Voyager mission, and, because of the nature of the satellite encounters, will produce images with approximately 100 times the ground resolution (i.e., ??? 50 m lp-1) on the Galilean satellites. We describe aspects of the detector including its sensitivity to energetic particle radiation and how the requirements for a large full-well capacity and long-term stability in operating voltages led to the choice of the virtual phase chip. The F/8.5 camera system can reach point sources of V(mag) ??? 11 with S/N ??? 10 and extended sources with surface brightness as low as 20 kR in its highest gain state and longest exposure mode. We describe the performance of the system as determined by ground calibration and the improvements that have been made to the telescope (same basic catadioptric design that was used in Mariner 10 and the Voyager high-resolution cameras) to reduce the scattered light reaching the detector. The images are linearly digitized 8-bits deep and, after flat-fielding, are cosmetically clean. Information 'preserving' and 'non-preserving' on-board data compression capabilities are outlined. A special "summation" mode, designed for use deep in the Jovian radiation belts, near Io, is also described. The detector is 'preflashed' before each exposure to ensure the photometric linearity

  13. Initial experience of 3 tesla endorectal coil magnetic resonance imaging and 1H-spectroscopic imaging of the prostate.

    NARCIS (Netherlands)

    Fütterer, J.J.; Scheenen, T.W.J.; Huisman, H.J.; Klomp, D.W.J.; Dorsten, F.A. van; Hulsbergen-van de Kaa, C.A.; Witjes, J.A.; Heerschap, A.; Barentsz, J.O.

    2004-01-01

    RATIONALE AND OBJECTIVES: We sought to explore the feasibility of magnetic resonance imaging (MRI) of the prostate at 3T, with the knowledge of potential drawbacks of MRI at high field strengths. MATERIAL AND METHOD: MRI, dynamic MRI, and 1H-MR spectroscopic imaging were performed in 10 patients

  14. A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience

    International Nuclear Information System (INIS)

    Pitre, S.; Menard, L.; Charon, Y.; Solal, M.; Garbay, J.R.

    2003-01-01

    Improvements in the specificity of radiopharmaceutical compounds have been paralleled by an upsurge of interest in developing small detectors to assist surgeons in localizing tumour tissue during surgery. This study reports the main technical features and physical characteristics of a new hand-held gamma camera dedicated to accurate and real-time intra-operative imaging. First clinical experience is also reported. The POCI (Per-operative Compact Imager) camera consists of a head module composed of a high-resolution interchangeable lead collimator and a CsI(Na) crystal plate optically coupled to an intensified position-sensitive diode. The current prototype has a 40-mm diameter field of view, an outer diameter of 9.5 cm, a length of 9 cm and a weight of 1.2 kg. Overall detector imaging characteristics were evaluated by technetium-99m phantom measurements. Three patients with breast cancer previously scheduled to undergo sentinel lymph node detection were selected for the preliminary clinical experience. Preoperative images of the lymphatic basin obtained using the POCI camera were compared with conventional transcutaneous explorations using a non-imaging gamma probe. The full-width at half-maximum (FWHM) spatial resolution was investigated in both air and scattering medium; when the phantom was placed in contact with the collimator, the POCI camera exhibited a 3.2 mm FWHM. The corresponding sensitivity was 290 cps/MBq. The preliminary clinical results showed that POCI was able to predict the number and location of all SLNs. In one case, two deep radioactive nodes missed by the gamma probe were detected on the intra-operative images. This very initial experience demonstrates that the physical performance of the POCI camera is adequate for radio-guided surgery. These results are sufficiently encouraging to prompt further evaluation studies designed to determine the specific and optimal clinical role of intra-operative imaging devices

  15. Diffusion-weighted MR imaging of neuro-Behcet's disease: initial and follow-up studies

    International Nuclear Information System (INIS)

    Heo, Suk Hee; Seo, Jeong Jin; Kim, Heung Joong; Chang, Nam Gyu; Shin, Sang Soo; Jeong, Yong Yeon; Jeong Gwang Woo; Kang, Heoung Keun

    2005-01-01

    To assess the usefulness of diffusion-weighted MR imaging (DWI) and apparent diffusion coefficient (ADC) in the initial and follow-up studies of patients with neuro-Behcet's disease. Six patients diagnosed with neuro-Behcet's disease were the subjects of this study. Initial and follow-up MR imaging were obtained in all six patients. Initial and follow-up DWI were also obtained is four of the six patients, with only an initial DWI in the other two. The DWI were obtained using multi-shot echo planar imaging, on a 1.5T MR unit, with two gradient steps (b values of 0, 1000 sec/mm 2 ). The ADC value and ADC maps were obtained using commercial software. The locations and signal intensities of the lesions were analyzed on conventional MRI and DWI, respectively. The ADC values of the lesions were calculated on the initial and follow-up DWI, and compared those of lesions in the normal contralateral regions. The initial DWI showed iso-signal intensities in four of the six patients, with high signal intensities in the other two. In five of the six patients, including three of the four that showed isosignal intensities and the two that showed high signal intensities on the initial DWI, the ADC values of the involved lesions were higher than those of the normal contralateral regions. In three of four that showed isosignal intensities, the ADC values of the lesions were decreased and normalized on the follow-up DWI. Obtaining DWI and ADC values in patients with neuro-Behcet's disease may be helpful in the understanding of pathophysiology and differential diagnosis of this disease

  16. North by Northwestern: initial experience with PACS at Northwestern Memorial Hospital

    Science.gov (United States)

    Channin, David S.; Hawkins, Rodney C.; Enzmann, Dieter R.

    2000-05-01

    This paper describes the initial phases and configuration of the Picture Archive and Communication System (PACS) deployed at Northwestern Memorial Hospital. The primary goals of the project were to improve service to patients, improve service to referring physicians, and improve the process of radiology. Secondary goals were to enhance the academic mission, and modernize institutional information systems. The system consists of a large number of heterogeneous imaging modalities sending imaging studies via DICOM to a GE medical Systems PathSpeed PACS. The radiology department workflow is briefly described. The system is currently storing approximately 140,000 studies and over 5 million images, growing by approximately 600 studies and 25,000 images per day. Data reflecting use of the short term and long term storage is provided.

  17. Gamma-ray imaging spectrometer (GRIS): a new balloon-borne experiment for gamma-ray line astronomy

    International Nuclear Information System (INIS)

    Teegarden, B.J.; Cline, T.L.; Gehrels, N.; Porreca, G.; Tueller, J.; Leventhal, M.; Huters, A.F.; MacCallum, C.J.; Stang, P.D.

    1985-01-01

    High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. Preliminary results such as the annihilation radiation from the galactic center, the 26 Al line from the galactic plane and cyclotron lines from neutron stars may well be just the initial discoveries of a rich and as yet undeveloped field. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload NASA decided to initiate a balloon program to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments. 6 refs., 2 figs

  18. Initially curved microplates under electrostatic actuation: theory and experiment

    KAUST Repository

    Saghir, Shahid; Bellaredj, Mohammed Lamine Faycal; Ramini, Abdallah; Younis, Mohammad I.

    2016-01-01

    Microplates are the building blocks of many micro-electro-mechanical systems. It is common for them to experience initial curvature imperfection due to residual stresses caused by the micro fabrication process. Such plates are essentially different

  19. Coronary artery imaging with 64-slice spiral CT in atrial fibrillation patients: initial experience

    International Nuclear Information System (INIS)

    Zhou Xuhui; Yan Chaogui; Xie Hongbo; Li Xiangmin; Li Ziping; Meng Quanfei; Chen Xing

    2008-01-01

    Objective: To discuss the clinical value of coronary artery imaging using 64-slice spiral CT in patient with atrial fibrillation. Methods: The images of 31 patients with atrial fibrillation who underwent contrast-enhanced CT coronary angiography were evaluated. The presence of stenosis on each segment of coronary arteries was recorded and their degree of stenosis was measured using the vessel analysis software. Ten patients additionally underwent conventional coronary angiography. The results of conventional coronary angiography were compared with CT coronary angiography of the 10 patients. Results: Image reconstruction was based on absolute timing. The image quality of 364 coronary vessel segments on the images from 31 patients was evaluated and defined as excellent, fine, moderate or poor. The image quality was excellent, fine, moderate and poor in 85, 41, 5, and 8 vessel segments respectively in patient group with heart rate between 47 beat per minent (bpm) and 69 bpm; and in 63, 16, 13, and 15 vessel segments respectively in patent group with heart rate between 70 bpm and 79 bpm;and in 46, 25, 23, and 24 vessel segments in patient group with heart rate between 80 bpm and 105 bpm. There was significant difference among the three patient groups (H=22.08, P<0.01). Comparison was carried out between CT angiographic findings and conventional angiographic findings of the 125 segments of the coronary arteries in the 10 patients who underwent conventional coronary angiography. The sensitivity and specificity of CT angiography for diagnosing vessel with significant coronary stenosis (≥50% narrowing) was 85.0% (17/20) and 95.2% (100/105), respectively. Positive predictive value was 77.3% (17/22), and negative predictive value was 97.1% (100/103). Coronary CTA underestimated the lesions of 3 vessel segments and overestimated the lesions of 5 vessel segments. Conclusion: Coronary artery imaging with 64-slice row CT had clinical value for patients with atrial fibrillation

  20. First Human Experience with Directly Image-able Iodinated Embolization Microbeads

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Elliot B., E-mail: levyeb@cc.nih.gov; Krishnasamy, Venkatesh P. [National Institutes of Health, Center for Interventional Oncology (United States); Lewis, Andrew L.; Willis, Sean; Macfarlane, Chelsea [Biocompatibles, UK Ltd, A BTG International Group Company (United Kingdom); Anderson, Victoria [National Institutes of Health, Center for Interventional Oncology (United States); Bom, Imramsjah MJ van der [Clinical Science IGT Systems North & Latin America, Philips, Philips, Image Guided Interventions (United States); Radaelli, Alessandro [Image-Guided Therapy Systems, Philips, Philips, Image Guided Interventions (Netherlands); Dreher, Matthew R. [Biocompatibles, UK Ltd, A BTG International Group Company (United Kingdom); Sharma, Karun V. [Children’s National Medical Center (United States); Negussie, Ayele; Mikhail, Andrew S. [National Institutes of Health, Center for Interventional Oncology (United States); Geschwind, Jean-Francois H. [Department of Radiology and Biomedical Imaging (United States); Wood, Bradford J. [National Institutes of Health, Center for Interventional Oncology (United States)

    2016-08-15

    PurposeTo describe first clinical experience with a directly image-able, inherently radio-opaque microspherical embolic agent for transarterial embolization of liver tumors.MethodologyLC Bead LUMI™ is a new product based upon sulfonate-modified polyvinyl alcohol hydrogel microbeads with covalently bound iodine (~260 mg I/ml). 70–150 μ LC Bead LUMI™ iodinated microbeads were injected selectively via a 2.8 Fr microcatheter to near complete flow stasis into hepatic arteries in three patients with hepatocellular carcinoma, carcinoid, or neuroendocrine tumor. A custom imaging platform tuned for LC LUMI™ microbead conspicuity using a cone beam CT (CBCT)/angiographic C-arm system (Allura Clarity FD20, Philips) was used along with CBCT embolization treatment planning software (EmboGuide, Philips).ResultsLC Bead LUMI™ image-able microbeads were easily delivered and monitored during the procedure using fluoroscopy, single-shot radiography (SSD), digital subtraction angiography (DSA), dual-phase enhanced and unenhanced CBCT, and unenhanced conventional CT obtained 48 h after the procedure. Intra-procedural imaging demonstrated tumor at risk for potential under-treatment, defined as paucity of image-able microbeads within a portion of the tumor which was confirmed at 48 h CT imaging. Fusion of pre- and post-embolization CBCT identified vessels without beads that corresponded to enhancing tumor tissue in the same location on follow-up imaging (48 h post).ConclusionLC Bead LUMI™ image-able microbeads provide real-time feedback and geographic localization of treatment in real time during treatment. The distribution and density of image-able beads within a tumor need further evaluation as an additional endpoint for embolization.

  1. Prospective Evaluation of Dual-Energy Imaging in Patients Undergoing Image Guided Radiation Therapy for Lung Cancer: Initial Clinical Results

    International Nuclear Information System (INIS)

    Sherertz, Tracy; Hoggarth, Mark; Luce, Jason; Block, Alec M.; Nagda, Suneel; Harkenrider, Matthew M.; Emami, Bahman; Roeske, John C.

    2014-01-01

    Purpose: A prospective feasibility study was conducted to investigate the utility of dual-energy (DE) imaging compared to conventional x-ray imaging for patients undergoing kV-based image guided radiation therapy (IGRT) for lung cancer. Methods and Materials: An institutional review board-approved feasibility study enrolled patients with lung cancer undergoing IGRT and was initiated in September 2011. During daily setup, 2 sequential respiration-gated x-ray images were obtained using an on-board imager. Imaging was composed of 1 standard x-ray image at 120 kVp (1 mAs) and a second image obtained at 60 kVp (4 mAs). Weighted logarithmic subtraction of the 2 images was performed offline to create a soft tissue-selective DE image. Conventional and DE images were evaluated by measuring relative contrast and contrast-to-noise ratios (CNR) and also by comparing spatial localization, using both approaches. Imaging dose was assessed using a calibrated ion chamber. Results: To date, 10 patients with stage IA to IIIA lung cancer were enrolled and 57 DE images were analyzed. DE subtraction resulted in complete suppression of overlying bone in all 57 DE images, with an average improvement in relative contrast of 4.7 ± 3.3 over that of 120 kVp x-ray images (P<.0002). The improvement in relative contrast with DE imaging was seen for both smaller (gross tumor volume [GTV] ≤5 cc) and larger tumors (GTV >5 cc), with average relative contrast improvement ratios of 3.4 ± 4.1 and 5.4 ± 3.6, respectively. Moreover, the GTV was reliably localized in 95% of the DE images versus 74% of the single energy (SE images, (P=.004). Mean skin dose per DE image set was 0.44 ± 0.03 mGy versus 0.43 ± 0.03 mGy, using conventional kV imaging parameters. Conclusions: Initial results of this feasibility study suggest that DE thoracic imaging may enhance tumor localization in lung cancer patients receiving kV-based IGRT without increasing imaging dose

  2. Gamma-Ray Imaging Spectrometer (GRIS): a new balloon-borne experiment for gamma-ray line astronomy

    International Nuclear Information System (INIS)

    Teegarden, B.J.; Cline, T.L.; Gehrels, N.; Porreca, G.; Tueller, J.; Leventhal, M.; Huters, A.F.; Maccallum, C.J.; Stang, P.D.; Sandia Labs., Albuquerque, NM)

    1985-01-01

    High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload, a balloon program was initiated to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments

  3. Fast fluid-attenuated inversion-recovery imaging: first experience with a 3D version in epilepsy

    International Nuclear Information System (INIS)

    Wieshmann, U.C.; Symms, M.R.; Bartlett, P.A.; Shorvon, S.D.; Barker, G.J.; Stevens, J.M.

    1998-01-01

    We developed a 3D version of fast fluid-attenuated inversion-recovery imaging (FLAIR) which provides images with a slice thickness of 1.5 mm. We present our initial experience with 3D fast FLAIR in patients with epilepsy. We compared 3D fast FLAIR (slice thickness 1.5 mm), 2D fast FLAIR (slice thickness 5 mm) and a 3D spoiled GRASS (IRSPGR) sequence (slice thickness 1.5 mm) in 10 patients with lesional epilepsy (head injury 1, hippocampal sclerosis 2, low-grade glioma 2, dysembryoplastic neuroepithelial tumour 2, polymicrogyria 1, perinatal infarct 1 and presumed thrombosed aneurysm 1). Both 2D and 3D fast FLAIR sequences yielded higher conspicuity for lesions than the T1-weighted IRSPGR sequence, except in the patient with polymicrogyria. The extent of the lesion, in particular that of low-grade tumours, was best assessed on 3D fast FLAIR images. 3D fast FLAIR may be a useful additional tool especially for imaging low-grade tumours. (orig.)

  4. Ultrasound Imaging Initiative

    Science.gov (United States)

    2003-01-01

    texture mapping hardware," IEEE Tranactions on Information Technology in Biomedicine, Submitted. [14] C.R. Castro Pareja , J.M. Jagadeesh and R. Shekhar...modulation in real-time three-dimensional sparse synthetic aperture ultrasound imaging systems "* Carlos R. Castro Pareja , Masters of Science, The Ohio...C.R. Castro Pareja , "An architecture for real-time image registration," M.S. Thesis, The Ohio State University, March 2002. 14. C.R. Castro Pareja , R

  5. Development of a personalized training system using the Lung Image Database Consortium and Image Database resource Initiative Database.

    Science.gov (United States)

    Lin, Hongli; Wang, Weisheng; Luo, Jiawei; Yang, Xuedong

    2014-12-01

    The aim of this study was to develop a personalized training system using the Lung Image Database Consortium (LIDC) and Image Database resource Initiative (IDRI) Database, because collecting, annotating, and marking a large number of appropriate computed tomography (CT) scans, and providing the capability of dynamically selecting suitable training cases based on the performance levels of trainees and the characteristics of cases are critical for developing a efficient training system. A novel approach is proposed to develop a personalized radiology training system for the interpretation of lung nodules in CT scans using the Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI) database, which provides a Content-Boosted Collaborative Filtering (CBCF) algorithm for predicting the difficulty level of each case of each trainee when selecting suitable cases to meet individual needs, and a diagnostic simulation tool to enable trainees to analyze and diagnose lung nodules with the help of an image processing tool and a nodule retrieval tool. Preliminary evaluation of the system shows that developing a personalized training system for interpretation of lung nodules is needed and useful to enhance the professional skills of trainees. The approach of developing personalized training systems using the LIDC/IDRL database is a feasible solution to the challenges of constructing specific training program in terms of cost and training efficiency. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  6. Initial experience with a nuclear medicine viewing workstation

    Science.gov (United States)

    Witt, Robert M.; Burt, Robert W.

    1992-07-01

    Graphical User Interfaced (GUI) workstations are now available from commercial vendors. We recently installed a GUI workstation in our nuclear medicine reading room for exclusive use of staff and resident physicians. The system is built upon a Macintosh platform and has been available as a DELTAmanager from MedImage and more recently as an ICON V from Siemens Medical Systems. The workstation provides only display functions and connects to our existing nuclear medicine imaging system via ethernet. The system has some processing capabilities to create oblique, sagittal and coronal views from transverse tomographic views. Hard copy output is via a screen save device and a thermal color printer. The DELTAmanager replaced a MicroDELTA workstation which had both process and view functions. The mouse activated GUI has made remarkable changes to physicians'' use of the nuclear medicine viewing system. Training time to view and review studies has been reduced from hours to about 30-minutes. Generation of oblique views and display of brain and heart tomographic studies has been reduced from about 30-minutes of technician''s time to about 5-minutes of physician''s time. Overall operator functionality has been increased so that resident physicians with little prior computer experience can access all images on the image server and display pertinent patient images when consulting with other staff.

  7. Remote diagnosis via a telecommunication satellite--ultrasonic tomographic image transmission experiments.

    Science.gov (United States)

    Nakajima, I; Inokuchi, S; Tajima, T; Takahashi, T

    1985-04-01

    An experiment to transmit ultrasonic tomographic section images required for remote medical diagnosis and care was conducted using the mobile telecommunication satellite OSCAR-10. The images received showed the intestinal condition of a patient incapable of verbal communication, however the image screen had a fairly coarse particle structure. On the basis of these experiments, were considered as the transmission of ultrasonic tomographic images extremely effective in remote diagnosis.

  8. Heidelberg Ion Therapy Center (HIT): Initial clinical experience in the first 80 patients

    Energy Technology Data Exchange (ETDEWEB)

    Combs, Stephanie E. (Univ. Hospital of Heidelberg, Dept. of Radiation Oncology, Heidelberg (Germany)), E-mail: Stephanie.Combs@med.uni-heidelberg.de; Ellerbrock, Malte; Haberer, Thomas (Heidelberger Ionenstrahl Therapiezentrum (HIT), Im Neuenheimer Feld 450, 69120 Heidelberg (Germany)) (and others)

    2010-10-15

    The Heidelberg Ion Therapy Center (HIT) started clinical operation in November 2009. In this report we present the first 80 patients treated with proton and carbon ion radiotherapy and describe patient selection, treatment planning and daily treatment for different indications. Patients and methods. Between November 15, 2009 and April 15, 2010, 80 patients were treated at the Heidelberg Ion Therapy Center (HIT) with carbon ion and proton radiotherapy. Main treated indications consisted of skull base chordoma (n = 9) and chondrosarcoma (n = 18), malignant salivary gland tumors (n=29), chordomas of the sacrum (n = 5), low grade glioma (n=3), primary and recurrent malignant astrocytoma and glioblastoma (n=7) and well as osteosarcoma (n = 3). Of these patients, four pediatric patients aged under 18 years were treated. Results. All patients were treated using the intensity-modulated rasterscanning technique. Seventy-six patients were treated with carbon ions (95%), and four patients were treated with protons. In all patients x-ray imaging was performed prior to each fraction. Treatment concepts were based on the initial experiences with carbon ion therapy at the Gesellschaft fuer Schwerionenforschung (GSI) including carbon-only treatments and carbon-boost treatments with photon-IMRT. The average time per fraction in the treatment room per patient was 29 minutes; for irradiation only, the mean time including all patients was 16 minutes. Position verification was performed prior to every treatment fraction with orthogonal x-ray imaging. Conclusion. Particle therapy could be included successfully into the clinical routine at the Dept. of Radiation Oncology in Heidelberg. Numerous clinical trials will subsequently be initiated to precisely define the role of proton and carbon ion radiotherapy in radiation oncology.

  9. The Track Imaging Cerenkov Experiment

    Science.gov (United States)

    Wissel, S. A.; Byrum, K.; Cunningham, J. D.; Drake, G.; Hays, E.; Horan, D.; Kieda, D.; Kovacs, E.; Macgill, S.; Nodulman, L.; hide

    2012-01-01

    We describe a dedicated cosmic-ray telescope that explores a new method for detecting Cerenkov radiation from high-energy primary cosmic rays and the large particle air shower they induce upon entering the atmosphere. Using a camera comprising 16 multi-anode photomultiplier tubes for a total of 256 pixels, the Track Imaging Cerenkov Experiment (TrICE) resolves substructures in particle air showers with 0.086deg resolution. Cerenkov radiation is imaged using a novel two-part optical system in which a Fresnel lens provides a wide-field optical trigger and a mirror system collects delayed light with four times the magnification. TrICE records well-resolved cosmic-ray air showers at rates ranging between 0.01-0.1 Hz.

  10. The Native American Experience. American Historical Images on File.

    Science.gov (United States)

    Wardwell, Lelia, Ed.

    This photo-documentation reference body presents more than 275 images chronicling the experiences of the American Indian from their prehistoric migrations to the present. The volume includes information and images illustrating the life ways of various tribes. The images are accompanied by historical information providing cultural context. The book…

  11. Initial clinical experience with a sac-anchoring endoprosthesis for aortic aneurysm repair.

    Science.gov (United States)

    Donayre, Carlos E; Zarins, Christopher K; Krievins, Dainis K; Holden, Andrew; Hill, Andrew; Calderas, Carlos; Velez, Jaime; White, Rodney A

    2011-03-01

    All current aortic endografts depend on proximal and distal fixation to prevent migration. However, migration and rupture can occur, particularly in patients with aortic necks that are short or angulated, or both. We present our initial clinical experience with a new sac-anchoring endoprosthesis designed to anchor and seal the device within the aneurysm sac. The initial worldwide experience using a new endoprosthesis for the treatment of aortic aneurysms (Nellix Endovascular, Palo Alto, Calif) was reviewed. The endoprosthesis consists of dual balloon-expandable endoframes surrounded by polymer-filled endobags designed to obliterate the aneurysm sac and maintain endograft position. Clinical results and follow-up contrast computed tomography (CT) scans at 30 days and 6 and 12 months were reviewed. The endograft was successfully deployed in 21 patients with infrarenal aortic aneurysms measuring 5.7 ± 0.7 cm (range, 4.3-7.4 cm). Two patients with common iliac aneurysms were treated with sac-anchoring extenders that maintained patency of the internal iliac artery. Infusion of 71 ± 37 mL of polymer (range, 19-158 mL) into the aortic endobags resulted in complete aneurysm exclusion in all patients. Mean implant time was 76 ± 35 minutes, with 33 ± 17 minutes of fluoroscopy time and 180 ± 81 mL of contrast; estimated blood loss was 174 ± 116 mL. One patient died during the postoperative period (30-day mortality, 4.8%), and one died at 10 months from non-device-related causes. During a mean follow-up of 8.7 ± 3.1 months and a median of 6.3 months, there were no late aneurysm- or device-related adverse events and no secondary procedures. CT imaging studies at 6 months and 1 year revealed no increase in aneurysm size, no device migration, and no new endoleaks. One patient had a limited proximal type I endoleak at 30 days that resolved at 60 days and remained sealed. One patient has an ongoing distal type I endoleak near the iliac bifurcation, with no change in aneurysm

  12. Breast vibro-acoustography: initial experience in benign lesions

    International Nuclear Information System (INIS)

    Alizad, Azra; Mehrmohammadi, Mohammad; Ghosh, Karthik; Glazebrook, Katrina N; Carter, Rickey E; Karaberkmez, Leman Gunbery; Whaley, Dana H; Fatemi, Mostafa

    2014-01-01

    Vibro-acoustography (VA) is a newly developed imaging technology that is based on low-frequency vibrations induced in the object by the radiation force of ultrasound. VA is sensitive to the dynamic characteristics of tissue. Here, we evaluate the performance of VA in identifying benign lesions and compare the results to those of mammography. An integrated mammography-VA system designed for in vivo breast imaging was tested on a group of female volunteers, age ≥ 18 years, with suspected breast lesions based on clinical examination. A set of VA scans was acquired after each corresponding mammography. Most lesions were classified as benign based on their histological results. However, in 4 cases, initial diagnosis based on clinical imaging determined that the lesions were cysts. These cysts were aspirated with needle aspiration and disappeared completely under direct ultrasound visualization. Therefore, no biopsies were performed on these cases and lesions were classified as benign based on clinical findings per clinical standards. To define the VA characteristics of benign breast masses, we adopted the features that are normally attributed to such masses in mammography. In a blinded assessment, three radiologists evaluated the VA images independently. The diagnostic accuracy of VA for detection of benign lesions was assessed by comparing the reviewers’ evaluations with clinical data. Out of a total 29 benign lesions in the group, the reviewers were able to locate all lesions on VA images and mammography, 100% with (95% confidence interval (CI): 88% to 100%). Two reviewers were also able to correctly classify 83% (95% CI: 65% to 92%), and the third reviewer 86% (95% CI: 65% to 95%) of lesions, as benign on VA images and 86% (95% CI: 69% to 95%) on mammography. The results suggest that the mammographic characteristics of benign lesion may also be used to identify such lesions in VA. Furthermore, the results show the ability of VA to detect benign breast

  13. Initial Results With Image-guided Cochlear Implant Programming in Children.

    Science.gov (United States)

    Noble, Jack H; Hedley-Williams, Andrea J; Sunderhaus, Linsey; Dawant, Benoit M; Labadie, Robert F; Camarata, Stephen M; Gifford, René H

    2016-02-01

    Image-guided cochlear implant (CI) programming can improve hearing outcomes for pediatric CI recipients. CIs have been highly successful for children with severe-to-profound hearing loss, offering potential for mainstreamed education and auditory-oral communication. Despite this, a significant number of recipients still experience poor speech understanding, language delay, and, even among the best performers, restoration to normal auditory fidelity is rare. Although significant research efforts have been devoted to improving stimulation strategies, few developments have led to significant hearing improvement over the past two decades. Recently introduced techniques for image-guided CI programming (IGCIP) permit creating patient-customized CI programs by making it possible, for the first time, to estimate the position of implanted CI electrodes relative to the nerves they stimulate using CT images. This approach permits identification of electrodes with high levels of stimulation overlap and to deactivate them from a patient's map. Previous studies have shown that IGCIP can significantly improve hearing outcomes for adults with CIs. The IGCIP technique was tested for 21 ears of 18 pediatric CI recipients. Participants had long-term experience with their CI (5 mo to 13 yr) and ranged in age from 5 to 17 years old. Speech understanding was assessed after approximately 4 weeks of experience with the IGCIP map. Using a two-tailed Wilcoxon signed-rank test, statistically significant improvement (p < 0.05) was observed for word and sentence recognition in quiet and noise, as well as pediatric self-reported quality-of-life (QOL) measures. Our results indicate that image guidance significantly improves hearing and QOL outcomes for pediatric CI recipients.

  14. Initial experience of oculodynamic MRI using ultrafast T2-weighted imaging

    International Nuclear Information System (INIS)

    Tanitame, Keizo; Kaichi, Yoko; Nakamura, Yuko

    2013-01-01

    We designed cine MRI protocol using sequential static half-Fourier single-shot rapid acquisition with relaxation enhancement (RARE) images with the subjects staring at the series of targets in front of their eyes. This technique was applied to three healthy volunteers and four patients with ocular motility disorders, including blow-out fracture, globe restriction due to a large posterior staphyloma, neurogenic strabismus (convergence disorder), and intraocular adhesion. In the volunteers, smooth movements of their visual foci and extraocular muscles were observed. In the patients, the ocular movement disturbances were demonstrated. Oculodynamic MRI provides functional information in cases of diplopia. (author)

  15. Nondestructive test for assembly relationship of initiating explosive device

    International Nuclear Information System (INIS)

    Wang Xiangang; Zhang Chaozong; Guo Zhiping

    2009-01-01

    A 3D computed tomography (CT) method to inspect assembly relationship of initiating explosive device and to nondestructively evaluate assembly relationship by building geometric model from CT images was described. The experiment result proves that this method accurately inspects assembly relationship of initiating explosive device. (authors)

  16. Choosing Wisely Imaging Recommendations: Initial Implementation in New England Emergency Departments

    Directory of Open Access Journals (Sweden)

    Ali S. Raja

    2017-04-01

    Full Text Available Introduction: In June 2016, the American College of Emergency Physicians (ACEP Emergency Quality Network began its Reduce Avoidable Imaging Initiative, designed to “reduce testing and imaging with low risk patients through the implementation of Choosing Wisely recommendations.” However, it is unknown whether New England emergency departments (ED have already implemented evidence-based interventions to improve adherence to ACEP Choosing Wisely recommendations related to imaging after their initial release in 2013. Our objective was to determine this, as well as whether provider-specific audit and feedback for imaging had been implemented in these EDs. Methods: This survey study was exempt from institutional review board review. In 2015, we mailed surveys to 195 hospital-affiliated EDs in all six New England states to determine whether they had implemented Choosing Wisely-focused interventions in 2014. Initial mailings included cover letters denoting the endorsement of each state’s ACEP chapter, and we followed up twice with repeat mailings to nonresponders. Data analysis included descriptive statistics and a comparison of state differences using Fisher’s exact test. Results: A total of 169/195 (87% of New England EDs responded, with all individual state response rates >80%. Overall, 101 (60% of responding EDs had implemented an intervention for at least one Choosing Wisely imaging scenario; 57% reported implementing a specific guideline/policy/clinical pathway and 28% reported implementing a computerized decision support system. The most common interventions were for chest computed tomography (CT in patients at low risk of pulmonary embolism (47% of EDs and head CT in patients with minor trauma (45% of EDs. In addition, 40% of EDs had implemented provider-specific audit and feedback, without significant interstate variation (range: 29-55%. Conclusion: One year after release of the ACEP Choosing Wisely recommendations, most New England EDs

  17. Developing students’ ideas about lens imaging: teaching experiments with an image-based approach

    Science.gov (United States)

    Grusche, Sascha

    2017-07-01

    Lens imaging is a classic topic in physics education. To guide students from their holistic viewpoint to the scientists’ analytic viewpoint, an image-based approach to lens imaging has recently been proposed. To study the effect of the image-based approach on undergraduate students’ ideas, teaching experiments are performed and evaluated using qualitative content analysis. Some of the students’ ideas have not been reported before, namely those related to blurry lens images, and those developed by the proposed teaching approach. To describe learning pathways systematically, a conception-versus-time coordinate system is introduced, specifying how teaching actions help students advance toward a scientific understanding.

  18. Initial results from the fast imaging solar spectrograph (FISS)

    CERN Document Server

    2015-01-01

    This collection of papers describes the instrument and initial results obtained from the Fast Imaging Solar Spectrograph (FISS),  one of the post-focus instruments of the 1.6 meter New Solar Telescope at the Big Bear Solar Observatory. The FISS primarily aims at investigating structures and dynamics of  chromospheric features. This instrument is a dual-band Echelle spectrograph optimized for the simultaneous recording of the H I 656.3 nm band and the Ca II 854.2 nm band. The imaging is done with the fast raster scan realized by the linear motion of a two-mirror scanner, and its quality is determined by the performance of the adaptive optics of the telescope.    These papers illustrate the capability of the early FISS observations in the study of chromospheric features. Since the imaging quality has been improved a lot with the advance of the adaptive optics, one can obtain much better data with the current FISS observations.        This volume is aimed at graduate students and researchers working in...

  19. Augmented Reality Guidance for the Resection of Missing Colorectal Liver Metastases: An Initial Experience.

    Science.gov (United States)

    Ntourakis, Dimitrios; Memeo, Ricardo; Soler, Luc; Marescaux, Jacques; Mutter, Didier; Pessaux, Patrick

    2016-02-01

    Modern chemotherapy achieves the shrinking of colorectal cancer liver metastases (CRLM) to such extent that they may disappear from radiological imaging. Disappearing CRLM rarely represents a complete pathological remission and have an important risk of recurrence. Augmented reality (AR) consists in the fusion of real-time patient images with a computer-generated 3D virtual patient model created from pre-operative medical imaging. The aim of this prospective pilot study is to investigate the potential of AR navigation as a tool to help locate and surgically resect missing CRLM. A 3D virtual anatomical model was created from thoracoabdominal CT-scans using customary software (VR RENDER(®), IRCAD). The virtual model was superimposed to the operative field using an Exoscope (VITOM(®), Karl Storz, Tüttlingen, Germany). Virtual and real images were manually registered in real-time using a video mixer, based on external anatomical landmarks with an estimated accuracy of 5 mm. This modality was tested in three patients, with four missing CRLM that had sizes from 12 to 24 mm, undergoing laparotomy after receiving pre-operative oxaliplatin-based chemotherapy. AR display and fine registration was performed within 6 min. AR helped detect all four missing CRLM, and guided their resection. In all cases the planned security margin of 1 cm was clear and resections were confirmed to be R0 by pathology. There was no postoperative major morbidity or mortality. No local recurrence occurred in the follow-up period of 6-22 months. This initial experience suggests that AR may be a helpful navigation tool for the resection of missing CRLM.

  20. Malignant pleural disease: diagnosis by using diffusion-weighted and dynamic contrast-enhanced MR imaging--initial experience.

    Science.gov (United States)

    Coolen, Johan; De Keyzer, Frederik; Nafteux, Philippe; De Wever, Walter; Dooms, Christophe; Vansteenkiste, Johan; Roebben, Ilse; Verbeken, Eric; De Leyn, Paul; Van Raemdonck, Dirk; Nackaerts, Kristiaan; Dymarkowski, Steven; Verschakelen, Johny

    2012-06-01

    To investigate the use of diffusion-weighted (DW) imaging for differentiating benign lesions from malignant pleural disease (MPD) and to retrospectively assess dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging acquisitions to find out whether combining these measurements with DW imaging could improve the diagnostic value of DW imaging. This study was approved by the local ethics committee, and all patients provided written informed consent. Thirty-one consecutive patients with pleural abnormalities suspicious for MPD underwent whole-body positron emission tomography (PET)/computed tomography (CT) and thorax MR examinations. Diagnostic thoracoscopy with histopathologic analysis of pleural biopsies served as the reference standard. First-line evaluation of each suspicious lesion was performed by using the apparent diffusion coefficient (ADC) calculated from the DW image, and the optimal cutoff value was found by using receiver operating characteristic curve analysis. Afterward, DCE MR imaging data were used to improve the diagnosis in the range of ADCs where DW imaging results were equivocal. Sensitivity, specificity, and accuracy of PET/CT for diagnosis of MPD were 100%, 35.3%, and 64.5%. The optimal ADC threshold to differentiate benign lesions from MPD with DW MR imaging was 1.52 × 10(-3) mm(2)/sec, with sensitivity, specificity, and accuracy of 71.4%, 100%, and 87.1%, respectively. This result could be improved to 92.8%, 94.1%, and 93.5%, respectively, when DCE MR imaging data were included in those cases where ADC was between 1.52 and 2.00 × 10(-3) mm(2)/sec. A total of 20 patients had disease diagnosed correctly, nine had disease diagnosed incorrectly, and two cases were undetermined with PET/CT. DW imaging helped stage disease correctly in 27 patients and incorrectly in four. The undetermined cases at PET/CT were correctly diagnosed at MR imaging. DW imaging is a promising tool for differentiating MPD from benign lesions, with high

  1. Basic principles of magnetic resonance imaging in cerebral ischemia and initial clinical experience

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Solomon, M.; Newton, T.H.; Weinstein, P.; Schmidley, J.; Norman, D.

    1985-01-01

    The basic principles of magnetic resonance imaging are described and their use in the investigation of cerebral ischemia outlined. A brief account is given of the clinical results of investigation to date

  2. Tumor scintigraphy by the method for subtracting the initial image with technetium-99m labeled antibody

    International Nuclear Information System (INIS)

    Karube, Yoshiharu; Katsuno, Kentaro; Ito, Sanae; Matsunaga, Kazuhisa; Takata, Jiro; Kuroki, Masahide; Murakami, Masaaki; Matsuoka, Yuji

    1999-01-01

    The method for subtracting the initial image from the localization image was evaluated for radioimmunoscintigraphy of tumors with technetium-99m (Tc-99m) labeled antibodies. Monoclonal antibodies were parental mouse and mouse-human chimeric antibodies to carcinoembryonic antigen (CEA), designated F11-39 and ChF11-39, respectively, both of which have been found to discriminate CEA in tumor tissues from the CEA-related antigens. After reduction of the intrinsic disulfide bonds, these antibodies were labeled with Tc-99m. In vivo studies were performed on athymic nude mice bearing the human CEA-producing gastric carcinoma xenografts. Though biodistribution results showed selective and progressive accumulation of Tc-99m labeled antibodies at the tumor site, high radioactivity in blood was inappropriate for scintigraphic visualization of the tumors within a few hours. We examined the subtraction of the initial Tc-99m image from the Tc-99m localization image after a few hours. Subtracted images of the same count reflected the in vivo behavior of the Tc-99m radioactivity. The subtracted scintigrams revealed excellent tumor images with no significant extrarenal background. Visualization of the tumor site was dependent on antigen-specific binding and nonspecific exudation. These results demonstrate that a method of subtraction of the initial image may serve as a potentially useful diagnostic method for an abnormal site for agents with a low pharmacokinetic value. (author)

  3. Initial experiences of family caregivers of survivors of a traumatic brain injury

    Directory of Open Access Journals (Sweden)

    Mandi Broodryk

    2015-08-01

    Full Text Available Background: There seems to be a paucity of research on the initial subjective experiences of family caregivers of survivors of a traumatic brain injury (TBI. Objective: To explore the challenges that family caregivers face during the initial stages of recovery of a relative who has sustained a TBI. Methods: Thematic analysis was used to explore the findings from semi-structured interviews that were conducted with 12 female family caregivers of relatives who had sustained a TBI. Results: Family caregivers recalled their initial experiences of the shock at hearing the news about their relative’s TBI, negative experiences in hospital and frustrating interactions with healthcare professionals as particularly challenging. Conclusion: The findings of this study emphasise caregivers’ need for support, information and psycho-education, especially from healthcare professionals, from the very beginning stages of recovery from a TBI. Practical and physical needs with regard to admission to and care in the hospital were also highlighted. This research will hopefully contribute to creating awareness amongst healthcare professionals on how they can contribute to improvement of the services provided by the healthcare system based on the experiences of the caregivers who participated in this study.

  4. EPID-based in vivo dosimetry for stereotactic body radiotherapy of non-small cell lung tumors: Initial clinical experience.

    Science.gov (United States)

    Consorti, R; Fidanzio, A; Brainovich, V; Mangiacotti, F; De Spirito, M; Mirri, M A; Petrucci, A

    2017-10-01

    EPID-based in vivo dosimetry (IVD) has been implemented for stereotactic body radiotherapy treatments of non-small cell lung cancer to check both isocenter dose and the treatment reproducibility comparing EPID portal images. 15 patients with lung tumors of small dimensions and treated with volumetric modulated arc therapy were enrolled for this initial experience. IVD tests supplied ratios R between in vivo reconstructed and planned isocenter doses. Moreover a γ-like analysis between daily EPID portal images and a reference one, in terms of percentage of points with γ-value smaller than 1, P γlevels of 5% for R ratio, P γlevel, and an average P γ90%. Paradigmatic discrepancies were observed in three patients: a set-up error and a patient morphological change were identified thanks to CBCT image analysis whereas the third discrepancy was not fully justified. This procedure can provide improved patient safety as well as a first step to integrate IVD and CBCT dose recalculation. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. British Isles Field Experience: An Initiative in International Education.

    Science.gov (United States)

    Martin, William J.

    The British Isles Field Experience (BIFE) program was initiated at Williamsport Area Community College (WACC) to provide a group of WACC faculty and staff members with individual and group activities of a personal, professional, and cultural nature in order to promote an international perspective that can be infused into student, collegiate, and…

  6. The impact of brand experience on attitudes and brand image : A quantitative study

    OpenAIRE

    Isotalo, Anni; Watanen, Samu

    2015-01-01

    Research questions: How to create an engaging brand experience in marketing context? How does an engaging brand experience affect consumer attitudes and brand image? Purpose of the study: The authors propose that the relationship between brand experience and formation of brand loyalty can be mediated by brand affect: positive attitude and brand image. The study discovers the components of an engaging brand experience and indicates their effect on consumer attitudes and brand image. Conclusion...

  7. Initial results of a positron tomograph for prostate imaging

    Energy Technology Data Exchange (ETDEWEB)

    Huber, J.S.; Choong, W.S.; Moses, W.W.; Qi, J.; Hu, J.; Wang,G.C.; Wilson, D.; Oh, S.; Huesman, R.H.; Derenzo, S.E.; Budinger, T.F.

    2004-11-29

    We present the status and initial images of a positrontomograph for prostate imaging that centers a patient between a pair ofexternal curved detector banks (ellipse: 45 cm minor, 70 cm major axis).The distance between detector banks adjusts to allow patient access andto position the detectors as closely as possible for maximum sensitivitywith patients of various sizes. Each bank is composed of two axial rowsof 20 CTI PET Systems HR+ block detectors for a total of 80 modules inthe camera. Compared to an ECAT HR PET system operating in 3D mode, ourcamera uses about one-quarter the number of detectors and hasapproximately the same sensitivity for a central point source, becauseour detectors are close to the patient. The individual detectors areangled in the plane to point towards the prostate to minimize resolutiondegradation in that region. The detectors are read out by modified CTIdata acquisition electronics. We have completed construction of thegantry and electronics, have developed detector calibration and dataacquisition software, and are taking coincidence data. We demonstratethat we can clearly visualize a "prostate" in a simple phantom.Reconstructed images of two phantoms are shown.

  8. The initial experience of trans-rectal ultrasound and biopsy in ...

    African Journals Online (AJOL)

    The initial experience of trans-rectal ultrasound and biopsy in diagnosis of carcinoma prostate in Gezira Hospital for Renal Disease and Surgery (GHRDS). Walaa Eldin Ibraheem, Sami Mahjoub Taha, Mustafa Omran Mansour, Mohammed El Imam Mohamed Ahmed ...

  9. F-18 FDG PET with coincidence detection, dual-head gamma camera, initial experience in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Chu, J.M.G.; Pocock, N.; Quach, T.; Camden, B.M.C. [Liverpool Health Services, Liverpool, NSW (Australia). Department of Nuclear Medicine and Clinical Ultrasound

    1998-06-01

    Full text: The development of Co-incidence Detection (CD) in gamma camera technology has allowed the use of positron radiopharmaceuticals in clinical practice without dedicated PET facilities. We report our initial experience of this technology in Oncological applications. All patients were administered 200 MBq of F- 18 FDG intravenously in a fasting state, with serum glucose below 8.9 mmol/L., and hydration well maintained. Tomography was performed using an ADAC Solus Molecular Co-incidence Detection (MCD) dual-head gamma camera, 60 minutes after administration and immediately after voiding. Tomography of the torso required up to three collections depending on the length of the patient, with each collection requiring 32 steps of 40 second duration, and a 50% overlap. Tomography of the brain required a single collection with 32 steps of 80 seconds. Patients were scanned in the supine position. An iterative reconstruction algorithm was employed without attenuation correction. All patients had histologically confirmed malignancy. Scan findings were correlated with results of all conventional diagnostic imaging procedures that were pertinent to the evaluation and management of each individual patient`s disease. Correlation with tumour type and treatment status was also undertaken. F-18 FDG uptake as demonstrated by CD-PET was increased in tumour bearing sites. The degree of increased uptake varied with tumour type and with treatment status. Our initial experience with CD-PET has been very encouraging, and has led us to undertake prospective short and long term studies to define its role in oncology

  10. SPECIAL ASPECTS OF INITIAL OPTICAL SCHEME SELECTION FOR DESIGN OF NON-IMAGING OPTICAL SYSTEMS

    OpenAIRE

    R. V. Anitropov; P. Benitez; I. L. Livshits S. K. Stafeev; S. K. Stafeev; V. N. Vasilev; M. V. Letunovskaya; A. S. Zaitceva

    2016-01-01

    Subject of Research. The research results, structural composition analysis and the parametric synthesis of the projected imaging and non-imaging optical systems were presented. We made an attempt to use the gained experience about imaging systems while designing non-imaging systems, by adapting the composition theory for the calculations of non-imaging systems. Several patterns were revealed, which provide a deeper understanding of the design process of non-imaging optical systems; measures ...

  11. Adult congenital heart disease imaging with second-generation dual-source computed tomography: initial experiences and findings.

    Science.gov (United States)

    Ghoshhajra, Brian B; Sidhu, Manavjot S; El-Sherief, Ahmed; Rojas, Carlos; Yeh, Doreen Defaria; Engel, Leif-Christopher; Liberthson, Richard; Abbara, Suhny; Bhatt, Ami

    2012-01-01

    Adult congenital heart disease patients present a unique challenge to the cardiac imager. Patients may present with both acute and chronic manifestations of their complex congenital heart disease and also require surveillance for sequelae of their medical and surgical interventions. Multimodality imaging is often required to clarify their anatomy and physiology. Radiation dose is of particular concern in these patients with lifelong imaging needs for their chronic disease. The second-generation dual-source scanner is a recently available advanced clinical cardiac computed tomography (CT) scanner. It offers a combination of the high-spatial resolution of modern CT, the high-temporal resolution of dual-source technology, and the wide z-axis coverage of modern cone-beam geometry CT scanners. These advances in technology allow novel protocols that markedly reduce scan time, significantly reduce radiation exposure, and expand the physiologic imaging capabilities of cardiac CT. We present a case series of complicated adult congenital heart disease patients imaged by the second-generation dual-source CT scanner with extremely low-radiation doses and excellent image quality. © 2012 Wiley Periodicals, Inc.

  12. Initial experience with the NRC significance determination process

    International Nuclear Information System (INIS)

    Madison, A.L.

    2001-01-01

    The U.S. Nuclear Regulatory Commission (NRC) has revamped its inspection, assessment, and enforcement programs for commercial nuclear power plants. The new oversight process uses more objective, timely, and safety-significant criteria in assessing performance, while seeking to more effectively and efficiently regulate the industry. The NRC tested the new process at thirteen reactors at nine sites across the country on a pilot basis in 1999 to identify what things worked well and what improvements were called for before beginning Initial Implementation at all US nuclear power plants on April 2, 2000. After a year of experience has been gained with the new oversight process at all US plants, the NRC anticipates making further improvements based on this wider experience. (author)

  13. Initial experience with the NRC significance determination process

    Energy Technology Data Exchange (ETDEWEB)

    Madison, A.L. [Office of Nuclear Reactor Regulation, US Nuclear Regulatory Commission (United States)

    2001-07-01

    The U.S. Nuclear Regulatory Commission (NRC) has revamped its inspection, assessment, and enforcement programs for commercial nuclear power plants. The new oversight process uses more objective, timely, and safety-significant criteria in assessing performance, while seeking to more effectively and efficiently regulate the industry. The NRC tested the new process at thirteen reactors at nine sites across the country on a pilot basis in 1999 to identify what things worked well and what improvements were called for before beginning Initial Implementation at all US nuclear power plants on April 2, 2000. After a year of experience has been gained with the new oversight process at all US plants, the NRC anticipates making further improvements based on this wider experience. (author)

  14. Improved initial guess with semi-subpixel level accuracy in digital image correlation by feature-based method

    Science.gov (United States)

    Zhang, Yunlu; Yan, Lei; Liou, Frank

    2018-05-01

    The quality initial guess of deformation parameters in digital image correlation (DIC) has a serious impact on convergence, robustness, and efficiency of the following subpixel level searching stage. In this work, an improved feature-based initial guess (FB-IG) scheme is presented to provide initial guess for points of interest (POIs) inside a large region. Oriented FAST and Rotated BRIEF (ORB) features are semi-uniformly extracted from the region of interest (ROI) and matched to provide initial deformation information. False matched pairs are eliminated by the novel feature guided Gaussian mixture model (FG-GMM) point set registration algorithm, and nonuniform deformation parameters of the versatile reproducing kernel Hilbert space (RKHS) function are calculated simultaneously. Validations on simulated images and real-world mini tensile test verify that this scheme can robustly and accurately compute initial guesses with semi-subpixel level accuracy in cases with small or large translation, deformation, or rotation.

  15. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience.

    Science.gov (United States)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang

    2017-01-01

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80 each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. • Automatic spectral imaging protocol selection provides appropriate scan protocols. • Abdominal CT is feasible using spectral imaging and 300 mgI/kg contrast agent. • 50-keV monochromatic images with 50 % ASIR provide optimal image quality.

  16. Three-Dimensional Neutral Transport Simulations of Gas Puff Imaging Experiments

    International Nuclear Information System (INIS)

    Stotler, D.P.; DIppolito, D.A.; LeBlanc, B.; Maqueda, R.J.; Myra, J.R.; Sabbagh, S.A.; Zweben, S.J.

    2003-01-01

    Gas Puff Imaging (GPI) experiments are designed to isolate the structure of plasma turbulence in the plane perpendicular to the magnetic field. Three-dimensional aspects of this diagnostic technique as used on the National Spherical Torus eXperiment (NSTX) are examined via Monte Carlo neutral transport simulations. The radial width of the simulated GPI images are in rough agreement with observations. However, the simulated emission clouds are angled approximately 15 degrees with respect to the experimental images. The simulations indicate that the finite extent of the gas puff along the viewing direction does not significantly degrade the radial resolution of the diagnostic. These simulations also yield effective neutral density data that can be used in an approximate attempt to infer two-dimensional electron density and temperature profiles from the experimental images

  17. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang [The First Affiliated Hospital of Zhengzhou University, Department of Radiology, Zhengzhou, Henan Province (China)

    2017-01-15

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80) each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. (orig.)

  18. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience

    International Nuclear Information System (INIS)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang

    2017-01-01

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80) each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. (orig.)

  19. Case of possible multiple system atrophy with a characteristic imaging finding of open bladder neck during storage phase as an initial sign.

    Science.gov (United States)

    Zhang, Lu; Haga, Nobuhiro; Ogawa, Soichiro; Matsuoka, Kanako; Koguchi, Tomoyuki; Akaihata, Hidenori; Hata, Junya; Kataoka, Masao; Ishibashi, Kei; Kojima, Yoshiyuki

    2017-11-01

    Multiple system atrophy is a neurodegenerative disease that affects autonomic and motor systems. Patients with multiple system atrophy usually experience lower urinary tract symptoms, which sometimes appear as an initial symptom before the emergence of the generalized symptoms. An open bladder neck during the filling phase on video urodynamic study is one characteristic imaging finding after the diagnosis of multiple system atrophy, but has not previously been reported at an early phase of the disease. We report a case in which an open bladder neck was observed on several imaging modalities before generalized symptoms emerged. Because occult neurogenic bladder might exist in patients whose lower urinary tract symptoms are resistant to pharmacotherapy, we report this case to raise awareness of the importance of sufficient imaging evaluations. An open bladder neck might be an important imaging finding for diagnosing multiple system atrophy, irrespective of the presence of generalized symptoms. This finding could help avoid false diagnosis and unnecessary treatment. © 2017 The Japanese Urological Association.

  20. Initial Clinical Experience Performing Patient Treatment Verification With an Electronic Portal Imaging Device Transit Dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Berry, Sean L., E-mail: BerryS@MSKCC.org [Department of Applied Physics and Applied Mathematics, Columbia University, New York, New York (United States); Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Polvorosa, Cynthia; Cheng, Simon; Deutsch, Israel; Chao, K. S. Clifford; Wuu, Cheng-Shie [Department of Radiation Oncology, Columbia University, New York, New York (United States)

    2014-01-01

    Purpose: To prospectively evaluate a 2-dimensional transit dosimetry algorithm's performance on a patient population and to analyze the issues that would arise in a widespread clinical adoption of transit electronic portal imaging device (EPID) dosimetry. Methods and Materials: Eleven patients were enrolled on the protocol; 9 completed and were analyzed. Pretreatment intensity modulated radiation therapy (IMRT) patient-specific quality assurance was performed using a stringent local 3%, 3-mm γ criterion to verify that the planned fluence had been appropriately transferred to and delivered by the linear accelerator. Transit dosimetric EPID images were then acquired during treatment and compared offline with predicted transit images using a global 5%, 3-mm γ criterion. Results: There were 288 transit images analyzed. The overall γ pass rate was 89.1% ± 9.8% (average ± 1 SD). For the subset of images for which the linear accelerator couch did not interfere with the measurement, the γ pass rate was 95.7% ± 2.4%. A case study is presented in which the transit dosimetry algorithm was able to identify that a lung patient's bilateral pleural effusion had resolved in the time between the planning CT scan and the treatment. Conclusions: The EPID transit dosimetry algorithm under consideration, previously described and verified in a phantom study, is feasible for use in treatment delivery verification for real patients. Two-dimensional EPID transit dosimetry can play an important role in indicating when a treatment delivery is inconsistent with the original plan.

  1. Preliminary results from initial in-pile debris bed experiments

    International Nuclear Information System (INIS)

    Rivard, J.B.

    1977-01-01

    An accident in a liquid metal fast breeder reactor (LMFBR) in which molten core material is suddenly quenched with subcooled liquid sodium could result in extensive fragmentation and dispersal of fuel as subcritical beds of frozen particulate debris within the reactor vessel. Since this debris will continue to generate power due to decay of retained fission products, containment of the debris is threatened if the generated heat is not removed. Therefore, the initial safety question is the capacity which debris beds may have for transfer of the decay heat to overlying liquid sodium by natural processes--i.e., without the aid of forced circulation of the coolant. Up to the present time, all experiments on debris bed behavior either have used substitute materials (e.g., sand and water) or have employed actual materials, but atypical heating methods. Increased confidence in the applicability of debris bed simulations is afforded if the heat is generated within the fuel component of the appropriate fast reactor materials. The initial series of in-pile tests reported on herein constitutes the first experiments in which the internal heating mode has been produced in particulate oxide fuel immersed in liquid sodium. Fission heating of the fully-enriched UO 2 in the experiment while it is contained within Sandia Laboratories Annular Core Pulse Reactor (ACPR), operating in its steady-state mode, approximates the decay heating of debris. Preliminary results are discussed

  2. PET CT imaging: the Philippine experience

    International Nuclear Information System (INIS)

    Santiago, Jonas Y.

    2011-01-01

    Currently, the most discussed fusion imaging is PET CT. Fusion technology has tremendous potential in diagnostic imaging to detect numerous conditions such as tumors, Alzheimer's disease, dementia and neural disorders. The fusion of PET with CT helps in the localization of molecular abnormalities, thereby increasing diagnostic accuracy and differentiating benign or artefact lesions from malignant diseases. It uses a radiotracer called fluro deoxyglucose that gives a clear distinction between pathological and physiological uptake. Interest in this technology is increasing and additional clinical validation are likely to induce more health care providers to invest in combined scanners. It is hope that in time, a better appreciation of its advantages over conventional and traditional imaging modalities will be realized. The first PET CT facility in the country was established at the St. Luke's Medical Center in Quezon City in 2008 and has since then provided a state-of-the art imaging modality to its patients here and those from other countries. The paper will present the experiences so far gained from its operation, including the measures and steps currently taken by the facility to ensure optimum workers and patient safety. Plans and programs to further enhance the awareness of the Filipino public on this advanced imaging modality for an improved health care delivery system may also be discussed briefly. (author)

  3. Analysis of molten fuel-coolant interaction during a reactivity-initiated accident experiment

    International Nuclear Information System (INIS)

    El-Genk, M.S.; Hobbins, R.R.

    1981-01-01

    The results of a reactivity-initiated accident experiment, designated RIA-ST-4, are discussed and analyzed with regard to molten fuel-coolant interaction (MFCI). In this experiment, extensive amounts of molten UO 2 fuel and zircaloy cladding were produced and fragmented upon mixing with the coolant. Coolant pressurization up to 35 MPa and coolant overheating in excess of 940 K occurred after fuel rod failure. The initial coolant conditions were similar to those in boiling water reactors during a hot startup (that is, coolant pressure of 6.45 MPa, coolant temperature of 538 K, and coolant flow rate of 85 cm 3 /s). It is concluded that the high coolant pressure recorded in the RIA-ST-4 experiment was caused by an energetic MFCI and was not due to gas release from the test rod at failure, Zr/water reaction, or to UO 2 fuel vapor pressure. The high coolant temperature indicated the presence of superheated steam, which may have formed during the expansion of the working fluid back to the initial coolant pressure; yet, the thermal-to-mechanical energy conversion ratio is estimated to be only 0.3%

  4. Initial Australian experience with daily ultrasound localisation for prostate radiotherapy

    International Nuclear Information System (INIS)

    Kneebone, A.; Fuller, M.W.; Williams, M.J.

    2003-01-01

    Variability in prostate position is a major problem in the delivery of external beam radiotherapy (EBRT). Daily ultrasound localisation prior to radiotherapy has become popular in the United States but to date has not been used clinically in Australia or New Zealand. Daily transabdominal ultrasound images through the prostate were acquired using the BAT ultrasound system. Contour data from the planning system is reconstructed at the same locations/angles as the BAT images. By overlaying the planned contours with the newly acquired images, the isocentre is adjusted to ensure that the prostate will be within the irradiated volume. After commissioning by Medical Physics, an initial pre-clinical trial period was adopted. This involved performing BAT alignments daily but treating to the planned isocentre in 30 patients. Eighty three percent of patients (25/30) had images judged to be of good or excellent quality by the reviewing radiation oncologist. It was noted that for each operator there was a period needed to build confidence/competence in both imaging and interpreting the images for the moves. The median scan time in addition to the normal patient set-up was 3.2 minutes (range=1.5-12.0 mins) with the second 15 patients scanned quicker than the first 15 (2.9 minutes versus 3.8 minutes). A summary of the movements recommended by the BAT system is contained in the table. We feel that daily prostate ultrasound localization offers a significant advance in delivering EBRT for prostate cancer. The incorporation of the system into clinical use, however, was not without difficulty and requires significant time and effort from therapists, physicists and medical staff. Further clinical evaluation of the unit is ongoing

  5. Interventional C-arm tomosynthesis for vascular imaging: initial results

    Science.gov (United States)

    Langan, David A.; Claus, Bernhard E. H.; Al Assad, Omar; Trousset, Yves; Riddell, Cyril; Avignon, Gregoire; Solomon, Stephen B.; Lai, Hao; Wang, Xin

    2015-03-01

    As percutaneous endovascular procedures address more complex and broader disease states, there is an increasing need for intra-procedure 3D vascular imaging. In this paper, we investigate C-Arm 2-axis tomosynthesis ("Tomo") as an alternative to C-Arm Cone Beam Computed Tomography (CBCT) for workflow situations in which the CBCT acquisition may be inconvenient or prohibited. We report on our experience in performing tomosynthesis acquisitions with a digital angiographic imaging system (GE Healthcare Innova 4100 Angiographic Imaging System, Milwaukee, WI). During a tomo acquisition the detector and tube each orbit on a plane above and below the table respectively. The tomo orbit may be circular or elliptical, and the tomographic half-angle in our studies varied from approximately 16 to 28 degrees as a function of orbit period. The trajectory, geometric calibration, and gantry performance are presented. We overview a multi-resolution iterative reconstruction employing compressed sensing techniques to mitigate artifacts associated with incomplete data reconstructions. In this work, we focus on the reconstruction of small high contrast objects such as iodinated vasculature and interventional devices. We evaluate the overall performance of the acquisition and reconstruction through phantom acquisitions and a swine study. Both tomo and comparable CBCT acquisitions were performed during the swine study thereby enabling the use of CBCT as a reference in the evaluation of tomo vascular imaging. We close with a discussion of potential clinical applications for tomo, reflecting on the imaging and workflow results achieved.

  6. Initial acceptance test experience with FFTF plant equipment

    International Nuclear Information System (INIS)

    Brown, R.K.; Coleman, K.A.; Mahaffey, M.K.; McCargar, C.G.; Young, M.W.

    1978-09-01

    The purpose of this paper is to examine the initial acceptance test experience of certain pieces of auxiliary equipment of the Fast Flux Test Facility (FFTF). The scope focuses on the DHX blowers and drive train, inert gas blowers, H and V containment isolation valves, and the Surveillance and In-service Inspection (SISI) transporter and trolley. For each type of equipment, the discussion includes a summary of the design and system function, installation history, preoperational acceptance testing procedures and results, and unusual events and resolutions

  7. The Community Reclaims Control? Learning Experiences from Rural Broadband Initiatives in the Netherlands

    NARCIS (Netherlands)

    Salemink, Koen; Strijker, Dirk; Bosworth, Gary

    2017-01-01

    Based on four illustrative case studies from the Netherlands, this article discusses learning experiences gained from rural broadband initiatives. As an example of the big society' (or participatiesamenleving' in Dutch), initiatives try to step in where the market and the government fail. The main

  8. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): A Completed Reference Database of Lung Nodules on CT Scans

    International Nuclear Information System (INIS)

    2011-01-01

    Purpose: The development of computer-aided diagnostic (CAD) methods for lung nodule detection, classification, and quantitative assessment can be facilitated through a well-characterized repository of computed tomography (CT) scans. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI) completed such a database, establishing a publicly available reference for the medical imaging research community. Initiated by the National Cancer Institute (NCI), further advanced by the Foundation for the National Institutes of Health (FNIH), and accompanied by the Food and Drug Administration (FDA) through active participation, this public-private partnership demonstrates the success of a consortium founded on a consensus-based process. Methods: Seven academic centers and eight medical imaging companies collaborated to identify, address, and resolve challenging organizational, technical, and clinical issues to provide a solid foundation for a robust database. The LIDC/IDRI Database contains 1018 cases, each of which includes images from a clinical thoracic CT scan and an associated XML file that records the results of a two-phase image annotation process performed by four experienced thoracic radiologists. In the initial blinded-read phase, each radiologist independently reviewed each CT scan and marked lesions belonging to one of three categories (''nodule≥3 mm,''''nodule<3 mm,'' and ''non-nodule≥3 mm''). In the subsequent unblinded-read phase, each radiologist independently reviewed their own marks along with the anonymized marks of the three other radiologists to render a final opinion. The goal of this process was to identify as completely as possible all lung nodules in each CT scan without requiring forced consensus. Results: The Database contains 7371 lesions marked ''nodule'' by at least one radiologist. 2669 of these lesions were marked ''nodule≥3 mm'' by at least one radiologist, of which 928 (34.7%) received such marks from all

  9. "Elite" Career-Changers and Their Experience of Initial Teacher Education

    Science.gov (United States)

    Wilkins, Chris

    2017-01-01

    This study explores the motivation of "high-status" professionals to change career and enter teaching, and their experience of undertaking initial teacher education (ITE) programmes in England. The study builds on previous research which found that career-changers are disproportionately more likely to fail to complete their ITE studies,…

  10. Understanding God images and God concepts: Towards a pastoral hermeneutics of the God attachment experience

    Directory of Open Access Journals (Sweden)

    Victor Counted

    2015-03-01

    Full Text Available The author looks at the God image experience as an attachment relationship experience with God. Hence, arguing that the God image experience is borne originally out of a parent�child attachment contagion, in such a way that God is often represented in either secure or insecure attachment patterns. The article points out that insecure God images often develop head-to-head with God concepts in a believer�s emotional experience of God. On the other hand, the author describes God concepts as indicators of a religious faith and metaphorical standards for regulating insecure attachment patterns. The goals of this article, however, is to highlight the relationship between God images and God concepts, and to provide a hermeneutical process for interpreting and surviving the God image experience.Intradisciplinary and/or interdisciplinary implications: Given that most scholars within the discipline of Practical Theology discuss the subject of God images from cultural and theological perspectives, this article has discussed God images from an attachment perspective, which is a popular framework in psychology of religion. This is rare. The study is therefore interdisciplinary in this regards. The article further helps the reader to understand the intrapsychic process of the God image experience, and thus provides us with hermeneutical answers for dealing with the God image experience from methodologies grounded in Practical Theology and pastoral care.

  11. DENOTATIVE ORIGINS OF ABSTRACT IMAGES IN LINGUISTIC EXPERIMENT

    Directory of Open Access Journals (Sweden)

    Elina, E.

    2017-03-01

    Full Text Available The article discusses the refusal from denotation (the subject, as the basic principle of abstract images, and semiotic problems arising in connection with this principle: how to solve the contradiction between the pointlessness and iconic nature of the image? Is it correct in the absence of denotation to recognize abstract representation of a single-level entity? The solution is proposed to decide these questions with the help of a psycholinguistic experiment in which the verbal interpretation of abstract images made by both experienced and “naive” audience-recipients demonstrates the objectivity of perception of denotative “traces” and the presence of denotative invariant in an abstract form.

  12. The Lusi seismic experiment: An initial study to understand the effect of seismic activity to Lusi

    Energy Technology Data Exchange (ETDEWEB)

    Karyono, E-mail: karyonosu@gmail.com [Agency for Meteorology, Climatology and Geophysics (BMKG), Jakarta (Indonesia); OSLO University (Norway); Padjadjaran University (UNPAD), Bandung (Indonesia); Mazzini, Adriano; Sugiharto, Anton [OSLO University (Norway); Lupi, Matteo [ETH Zurich (Switzerland); Syafri, Ildrem [Padjadjaran University (UNPAD), Bandung (Indonesia); Masturyono,; Rudiyanto, Ariska; Pranata, Bayu; Muzli,; Widodo, Handi Sulistyo; Sudrajat, Ajat [Agency for Meteorology, Climatology and Geophysics (BMKG), Jakarta (Indonesia)

    2015-04-24

    The spectacular Lumpur Sidoarjo (Lusi) eruption started in northeast Java on the 29 of May 2006 following a M6.3 earthquake striking the island [1,2]. Initially, several gas and mud eruption sites appeared along the reactivated strike-slip Watukosek fault system [3] and within weeks several villages were submerged by boiling mud. The most prominent eruption site was named Lusi. The Lusi seismic experiment is a project aims to begin a detailed study of seismicity around the Lusi area. In this initial phase we deploy 30 seismometers strategically distributed in the area around Lusi and along the Watukosek fault zone that stretches between Lusi and the Arjuno Welirang (AW) complex. The purpose of the initial monitoring is to conduct a preliminary seismic campaign aiming to identify the occurrence and the location of local seismic events in east Java particularly beneath Lusi.This network will locate small event that may not be captured by the existing BMKG network. It will be crucial to design the second phase of the seismic experiment that will consist of a local earthquake tomography of the Lusi-AW region and spatial and temporal variations of vp/vs ratios. The goal of this study is to understand how the seismicity occurring along the Sunda subduction zone affects to the behavior of the Lusi eruption. Our study will also provide a large dataset for a qualitative analysis of earthquake triggering studies, earthquake-volcano and earthquake-earthquake interactions. In this study, we will extract Green’s functions from ambient seismic noise data in order to image the shallow subsurface structure beneath LUSI area. The waveform cross-correlation technique will be apply to all of recordings of ambient seismic noise at 30 seismographic stations around the LUSI area. We use the dispersive behaviour of the retrieved Rayleigh waves to infer velocity structures in the shallow subsurface.

  13. Quantitative MR imaging in fracture dating--Initial results.

    Science.gov (United States)

    Baron, Katharina; Neumayer, Bernhard; Widek, Thomas; Schick, Fritz; Scheicher, Sylvia; Hassler, Eva; Scheurer, Eva

    2016-04-01

    For exact age determinations of bone fractures in a forensic context (e.g. in cases of child abuse) improved knowledge of the time course of the healing process and use of non-invasive modern imaging technology is of high importance. To date, fracture dating is based on radiographic methods by determining the callus status and thereby relying on an expert's experience. As a novel approach, this study aims to investigate the applicability of magnetic resonance imaging (MRI) for bone fracture dating by systematically investigating time-resolved changes in quantitative MR characteristics after a fracture event. Prior to investigating fracture healing in children, adults were examined for this study in order to test the methodology for this application. Altogether, 31 MR examinations in 17 subjects (♀: 11 ♂: 6; median age 34 ± 15 y, scanned 1-5 times over a period of up to 200 days after the fracture event) were performed on a clinical 3T MR scanner (TimTrio, Siemens AG, Germany). All subjects were treated conservatively for a fracture in either a long bone or in the collar bone. Both, qualitative and quantitative MR measurements were performed in all subjects. MR sequences for a quantitative measurement of relaxation times T1 and T2 in the fracture gap and musculature were applied. Maps of quantitative MR parameters T1, T2, and magnetisation transfer ratio (MTR) were calculated and evaluated by investigating changes over time in the fractured area by defined ROIs. Additionally, muscle areas were examined as reference regions to validate this approach. Quantitative evaluation of 23 MR data sets (12 test subjects, ♀: 7 ♂: 5) showed an initial peak in T1 values in the fractured area (T1=1895 ± 607 ms), which decreased over time to a value of 1094 ± 182 ms (200 days after the fracture event). T2 values also peaked for early-stage fractures (T2=115 ± 80 ms) and decreased to 73 ± 33 ms within 21 days after the fracture event. After that time point, no

  14. Accuracy and initial clinical experience with measurement software (advanced vessel analysis) in three-dimensional imaging

    International Nuclear Information System (INIS)

    Abe, Toshi; Hirohata, Masaru; Tanigawa, Hitoshi

    2002-01-01

    Recently, the clinical benefits of three dimensional (3D) imaging, such as 3D-CTA and 3D-DSA, in cerebro-vascular disease have been widely recognized. Software for quantitative analysis of vascular structure in 3D imaging (advanced vessel analysis: AVA) has been developed. We evaluated AVA with both phantom studies and a few clinical cases. In spiral and curvy aluminum tube phantom studies, the accuracy of diameter measurements was good in 3D images produced from data set generated by multi-detector row CT or rotational angiography. The measurement error was less than 0.03 mm on aluminum tube phantoms that were 3 mm and 5 mm in diameter. In the clinical studies, the differences of carotid artery diameter measurements between 2D-DSA and 3D-DSA was less than 0.3 mm in. The measurement of length, diameter and angle by AVA should provide useful information for planning surgical and endovascular treatments of cerebro-vascular disease. (author)

  15. Dynamic oxygen-enhanced magnetic resonance imaging of the lung in asthma—Initial experience

    International Nuclear Information System (INIS)

    Zhang, Wei-Juan; Niven, Robert M.; Young, Simon S.; Liu, Yu-Zhen; Parker, Geoffrey J.M.; Naish, Josephine H.

    2015-01-01

    Highlights: • Oxygen-enhanced MRI may have a role in the estimation of disease severity in asthma. • Heterogeneity of parameter maps reflects localized functional impairment in asthma. • OE-MRI provides non-ionising, spatial and temporal information on oxygen delivery. - Abstract: Objectives: To prospectively estimate the feasibility and reproducibility of dynamic oxygen-enhanced magnetic resonance imaging (OE-MRI) in the assessment of regional oxygen delivery, uptake and washout in asthmatic lungs. Materials and methods: The study was approved by the National Research Ethics Committee and written informed consent was obtained. Dynamic OE-MRI was performed twice at one month apart on four mild asthmatic patients (23 ± 5 years old, FEV 1 = 96 ± 3% of predicted value) and six severe asthmatic patients (41 ± 12 years old, FEV 1 = 60 ± 14% of predicted value) on a 1.5 T MR scanner using a two-dimensional T 1 -weighted inversion-recovery turbo spin echo sequence. The enhancing fraction (EF), the maximal change in the partial pressure of oxygen in lung tissue (ΔPO 2max l ) and arterial blood of the aorta (ΔPO 2max a ), and the oxygen wash-in (τ up l , τ up a ) and wash-out (τ down l , τ down a ) time constants were extracted and compared between groups using the independent-samples t-test (two-tailed). Correlations between imaging readouts and clinical measurements were assessed by Pearson's correlation analysis. Bland–Altman analysis was used to estimate the levels of agreement between the repeat scans and the intra-observer agreement in the MR imaging readouts. Results: The severe asthmatic group had significantly smaller EF (70 ± 16%) and median ΔPO 2max l (156 ± 52 mmHg) and significantly larger interquartile range of τ up l (0.84 ± 0.26 min) than the mild asthmatic group (95 ± 3%, P = 0.014; 281 ± 40 mmHg, P = 0.004; 0.20 ± 0.07 min, P = 0.001, respectively). EF, median ΔPO 2max l and τ down l and the interquartile range of τ up l

  16. Young adult women's experiences of body image after bariatric surgery

    DEFF Research Database (Denmark)

    Jensen, Janet F; Hoegh-Petersen, Mette; Larsen, Tine B

    2014-01-01

    AIM: To understand the lived experience of body image in young women after obesity surgery. BACKGROUND: Quantitative studies have documented that health-related quality of life and body image are improved after bariatric surgery, probably due to significant weight loss. Female obesity surgery...... candidates are likely to be motivated by dissatisfaction regarding physical appearance. However, little is known about the experience of the individual woman, leaving little understanding of the association between bariatric surgery and changes in health-related quality of life and body image. DESIGN...... analysed by systematic text condensation influenced by Giorgi's phenomenological method and supplemented by elements from narrative analysis. FINDINGS: The analysis revealed three concepts: solution to an unbearable problem, learning new boundaries and hopes of normalization. These revelatory concepts were...

  17. Knee osteoarthritis image registration: data from the Osteoarthritis Initiative

    Science.gov (United States)

    Galván-Tejada, Jorge I.; Celaya-Padilla, José M.; Treviño, Victor; Tamez-Peña, José G.

    2015-03-01

    Knee osteoarthritis is a very common disease, in early stages, changes in joint structures are shown, some of the most common symptoms are; formation of osteophytes, cartilage degradation and joint space reduction, among others. Based on a joint space reduction measurement, Kellgren-Lawrence grading scale, is a very extensive used tool to asses radiological OA knee x-ray images, based on information obtained from these assessments, the objective of this work is to correlate the Kellgren-Lawrence score to the bilateral asymmetry between knees. Using public data from the Osteoarthritis initiative (OAI), a set of images with different Kellgren-Lawrencescores were used to determine a relationship of Kellgren-Lawrence score and the bilateral asymmetry, in order to measure the asymmetry between the knees, the right knee was registered to match the left knee, then a series of similarity metrics, mutual information, correlation, and mean squared error where computed to correlate the deformation (mismatch) of the knees to the Kellgren-Lawrence score. Radiological information was evaluated and scored by OAI radiologist groups. The results of the study suggest an association between Radiological Kellgren-Lawrence score and image registration metrics, mutual information and correlation is higher in the early stages, and mean squared error is higher in advanced stages. This association can be helpful to develop a computer aided grading tool.

  18. Dynamic crack initiation toughness : experiments and peridynamic modeling.

    Energy Technology Data Exchange (ETDEWEB)

    Foster, John T.

    2009-10-01

    This is a dissertation on research conducted studying the dynamic crack initiation toughness of a 4340 steel. Researchers have been conducting experimental testing of dynamic crack initiation toughness, K{sub Ic}, for many years, using many experimental techniques with vastly different trends in the results when reporting K{sub Ic} as a function of loading rate. The dissertation describes a novel experimental technique for measuring K{sub Ic} in metals using the Kolsky bar. The method borrows from improvements made in recent years in traditional Kolsky bar testing by using pulse shaping techniques to ensure a constant loading rate applied to the sample before crack initiation. Dynamic crack initiation measurements were reported on a 4340 steel at two different loading rates. The steel was shown to exhibit a rate dependence, with the recorded values of K{sub Ic} being much higher at the higher loading rate. Using the knowledge of this rate dependence as a motivation in attempting to model the fracture events, a viscoplastic constitutive model was implemented into a peridynamic computational mechanics code. Peridynamics is a newly developed theory in solid mechanics that replaces the classical partial differential equations of motion with integral-differential equations which do not require the existence of spatial derivatives in the displacement field. This allows for the straightforward modeling of unguided crack initiation and growth. To date, peridynamic implementations have used severely restricted constitutive models. This research represents the first implementation of a complex material model and its validation. After showing results comparing deformations to experimental Taylor anvil impact for the viscoplastic material model, a novel failure criterion is introduced to model the dynamic crack initiation toughness experiments. The failure model is based on an energy criterion and uses the K{sub Ic} values recorded experimentally as an input. The failure model

  19. Evaluation of esophageal peristalsis in patients with esophageal tumors. Initial experience with cine MR imaging

    International Nuclear Information System (INIS)

    Koyama, Takashi; Kobayashi, Ari; Hiraga, Akira; Umeoka, Shigeaki; Saga, Tsuneo; Watanabe, Go; Tamai, Ken; Shimada, Yutaka; Togashi, Kaori

    2005-01-01

    We evaluated esophageal peristalsis in patients with esophageal tumors by cine MR using steady-state free precession (SSFP) sequence and correlated the alteration of the esophageal peristalsis with clinical symptoms and tumor stages. Thirteen patients with pathologically proven esophageal tumors, including 12 esophageal cancers and one submucosal leiomyoma, underwent cine MRI using true fast imaging with steady precession (trueFISP) sequence, which is one SSFP sequence, after contrast-enhanced MR scanning for clinical purposes. A total of 120 serial images were obtained within 60 s through the plane along the long axis of the esophagus while patients chewed gum. The serial trueFISP images were evaluated for the presence, frequency, speed of progression, and passage of peristalsis through the tumor. The data from cine MRI were compared with clinical symptoms and tumor stages. Peristalsis was clearly identified in all patients. Seven patients with complete interruption of peristalsis had dysphagia; one with partially impaired peristalsis could intake solid foods with discomfort; and two with partially impaired peristalsis and three with preserved peristalsis remained asymptomatic. Patients with complete or partial interruption of peristalsis had Stage T3 or T4 esophageal cancer. In conclusion, trueFISP cine MR imaging enables direct visualization of esophageal peristalsis in relation to esophageal tumors. Complete interruption of peristalsis causes dysphagia, whereas partial interruption of and preserved peristalsis usually do not cause digestive problems. Interruption of peristalsis may indicate impaired muscle function caused by invasion of advanced esophageal cancers. (author)

  20. Blast experiments for the derivation of initial cloud dimensions after a ''Dirty Bomb'' event

    International Nuclear Information System (INIS)

    Thielen, H.; Schroedl, E.

    2004-01-01

    Basis for the assessment of potential consequences of a ''dirty bomb'' event is the calculation of the atmospheric dispersion of airborne particles. The empirical derivation of parameters for the estimation of the initial pollutant cloud dimensions was the principal purpose for blast experiments performed in the training area Munster in summer 2003 with the participation of several highly engaged German organisations and institutions. The experiments were performed under variation of parameters like mass and kind of explosive, subsurface characteristics or meteorological conditions and were documented by digital video recording. The blasting experiments supplied significant results under reproducible conditions. The initial cloud dimension was primarily influenced by the explosive mass. The influence of other parameters was relatively small and within the range of the experimental uncertainties. Based on these experimental results a new correlation was determined for the empirical estimation of the initial cloud dimensions as a function of explosive mass. The observed initial cloud volumes were more than an order of magnitude smaller than those calculated with other widely-used formulas (e.g. HOTSPOT). As a smaller volume of the initial cloud leads to higher near-ground concentration maxima, our results support an appropriate adjustment of currently employed calculation methods. (orig.)

  1. Spectroscopic Needs for Imaging Dark Energy Experiments

    International Nuclear Information System (INIS)

    Newman, Jeffrey A.; Abate, Alexandra; Abdalla, Filipe B.; Allam, Sahar; Allen, Steven W.; Ansari, Reza; Bailey, Stephen; Barkhouse, Wayne A.; Beers, Timothy C.; Blanton, Michael R.; Brodwin, Mark; Brownstein, Joel R.; Brunner, Robert J.; Carrasco-Kind, Matias; Cervantes-Cota, Jorge; Chisari, Nora Elisa; Colless, Matthew; Coupon, Jean; Cunha, Carlos E.; Frye, Brenda L.; Gawiser, Eric J.; Gehrels, Neil; Grady, Kevin; Hagen, Alex; Hall, Patrick B.; Hearin, Andrew P.; Hildebrandt, Hendrik; Hirata, Christopher M.; Ho, Shirley; Huterer, Dragan; Ivezic, Zeljko; Kneib, Jean-Paul; Kruk, Jeffrey W.; Lahav, Ofer; Mandelbaum, Rachel; Matthews, Daniel J.; Miquel, Ramon; Moniez, Marc; Moos, H. W.; Moustakas, John; Papovich, Casey; Peacock, John A.; Rhodes, Jason; Ricol, Jean-Stepane; Sadeh, Iftach; Schmidt, Samuel J.; Stern, Daniel K.; Tyson, J. Anthony; Von der Linden, Anja; Wechsler, Risa H.; Wood-Vasey, W. M.; Zentner, A.

    2015-01-01

    Ongoing and near-future imaging-based dark energy experiments are critically dependent upon photometric redshifts (a.k.a. photo-z's): i.e., estimates of the redshifts of objects based only on flux information obtained through broad filters. Higher-quality, lower-scatter photo-z's will result in smaller random errors on cosmological parameters; while systematic errors in photometric redshift estimates, if not constrained, may dominate all other uncertainties from these experiments. The desired optimization and calibration is dependent upon spectroscopic measurements for secure redshift information; this is the key application of galaxy spectroscopy for imaging-based dark energy experiments. Hence, to achieve their full potential, imaging-based experiments will require large sets of objects with spectroscopically-determined redshifts, for two purposes: Training: Objects with known redshift are needed to map out the relationship between object color and z (or, equivalently, to determine empirically-calibrated templates describing the rest-frame spectra of the full range of galaxies, which may be used to predict the color-z relation). The ultimate goal of training is to minimize each moment of the distribution of differences between photometric redshift estimates and the true redshifts of objects, making the relationship between them as tight as possible. The larger and more complete our ''training set'' of spectroscopic redshifts is, the smaller the RMS photo-z errors should be, increasing the constraining power of imaging experiments; Requirements: Spectroscopic redshift measurements for ∼30,000 objects over >∼15 widely-separated regions, each at least ∼20 arcmin in diameter, and reaching the faintest objects used in a given experiment, will likely be necessary if photometric redshifts are to be trained and calibrated with conventional techniques. Larger, more complete samples (i.e., with longer exposure times) can improve photo

  2. Dual-contrast agent photon-counting computed tomography of the heart: initial experience.

    Science.gov (United States)

    Symons, Rolf; Cork, Tyler E; Lakshmanan, Manu N; Evers, Robert; Davies-Venn, Cynthia; Rice, Kelly A; Thomas, Marvin L; Liu, Chia-Ying; Kappler, Steffen; Ulzheimer, Stefan; Sandfort, Veit; Bluemke, David A; Pourmorteza, Amir

    2017-08-01

    To determine the feasibility of dual-contrast agent imaging of the heart using photon-counting detector (PCD) computed tomography (CT) to simultaneously assess both first-pass and late enhancement of the myocardium. An occlusion-reperfusion canine model of myocardial infarction was used. Gadolinium-based contrast was injected 10 min prior to PCD CT. Iodinated contrast was infused immediately prior to PCD CT, thus capturing late gadolinium enhancement as well as first-pass iodine enhancement. Gadolinium and iodine maps were calculated using a linear material decomposition technique and compared to single-energy (conventional) images. PCD images were compared to in vivo and ex vivo magnetic resonance imaging (MRI) and histology. For infarct versus remote myocardium, contrast-to-noise ratio (CNR) was maximal on late enhancement gadolinium maps (CNR 9.0 ± 0.8, 6.6 ± 0.7, and 0.4 ± 0.4, p contrast agent cardiac imaging is feasible with photon-counting detector CT. These initial proof-of-concept results may provide incentives to develop new k-edge contrast agents, to investigate possible interactions between multiple simultaneously administered contrast agents, and to ultimately bring them to clinical practice.

  3. Comparison of the initial ETA gas propagation experiments with theoretical models

    Energy Technology Data Exchange (ETDEWEB)

    Chambers, F.W.; Clark, J.C.; Fessenden, T.J.

    1982-04-20

    This report contains a description of the initial ETA propagation experiments in air at a beam current of 4.5 kA. The beam was observed to propagate at the pressures anticipated on the basis of previous theory and experiment. A comparison of measured net current waveforms with predictions of the PHOENIX code showed good agreement over the pressure range 0.1 to 200 torr. However, the beam was observed to expand with Z at a faster rate than theory predicts. Excessive transverse beam modulation at injection complicated the experiments and limited their comparison with theory.

  4. Comparison of the initial ETA gas propagation experiments with theoretical models

    International Nuclear Information System (INIS)

    Chambers, F.W.; Clark, J.C.; Fessenden, T.J.

    1982-01-01

    This report contains a description of the initial ETA propagation experiments in air at a beam current of 4.5 kA. The beam was observed to propagate at the pressures anticipated on the basis of previous theory and experiment. A comparison of measured net current waveforms with predictions of the PHOENIX code showed good agreement over the pressure range 0.1 to 200 torr. However, the beam was observed to expand with Z at a faster rate than theory predicts. Excessive transverse beam modulation at injection complicated the experiments and limited their comparison with theory

  5. Shock initiation experiments on ratchet grown PBX 9502

    Energy Technology Data Exchange (ETDEWEB)

    Gustavsen, Richard L [Los Alamos National Laboratory; Thompson, Darla G [Los Alamos National Laboratory; Olinger, Barton W [Los Alamos National Laboratory; Deluca, Racci [Los Alamos National Laboratory; Bartram, Brian D [Los Alamos National Laboratory; Pierce, Timothy H [Los Alamos National Laboratory; Sanchez, Nathaniel J [Los Alamos National Laboratory

    2010-01-01

    This study compares the shock initiation behavior of PBX 9502 pressed to less than nominal density (nominal density is 1.890 {+-} 0.005 g/cm{sup 3}) with PBX 9502 pressed to nominal density and then ''ratchet grown'' to low density. PBX 9502 is an insensitive plastic bonded explosive consisting of 95 weight % dry-aminated tri-amino-tri-nitro-benzene (TATB) and 5 weight % Kel-F 800 plastic binder. ''Ratchet growth'' - an irreversible increase in specific volume - occurs when an explosive based on TATB is temperature cycled. The design of our study is as follows: PBX 9502, all from the same lot, received the following four treatments. Samples in the first group were pressed to less than nominal density. These were not ratchet grown and used as a baseline. Samples in the second group were pressed to nominal density and then ratchet grown by temperature cycling 30 times between -54 C and +80 C. Samples in the final group were pressed to nominal density and cut into 100 mm by 25.4 mm diameter cylinders. During thermal cycling the cylinders were axially constrained by a 100 psi load. Samples for shock initiation experiments were cut perpendicular (disks) and parallel (slabs) to the axial load. The four sample groups can be summarized with the terms pressed low, ratchet grown/no load, axial load/disks, and axial load/slabs. All samples were shock initiated with nearly identical inputs in plate impact experiments carried out on a gas gun. Wave profiles were measured after propagation through 3, 4, 5, and 6 mm of explosive. Side by side comparison of wave profiles from different samples is used as a measure of relative sensitivity. All reduced density samples were more shock sensitive than nominal density PBX 9502. Differences in shock sensitivity between ratchet grown and pressed to low density PBX 9502 were small, but the low density pressings are slightly more sensitive than the ratchet grown samples.

  6. Experience with CANDID: Comparison algorithm for navigating digital image databases

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, P.; Cannon, M.

    1994-10-01

    This paper presents results from the authors experience with CANDID (Comparison Algorithm for Navigating Digital Image Databases), which was designed to facilitate image retrieval by content using a query-by-example methodology. A global signature describing the texture, shape, or color content is first computed for every image stored in a database, and a normalized similarity measure between probability density functions of feature vectors is used to match signatures. This method can be used to retrieve images from a database that are similar to a user-provided example image. Results for three test applications are included.

  7. Dynamic oxygen-enhanced magnetic resonance imaging of the lung in asthma—Initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei-Juan, E-mail: weijuan.zhang@postgrad.manchester.ac.uk [Centre for Imaging Sciences, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom); Biomedical Imaging Institute, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom); Niven, Robert M., E-mail: robert.niven@uhsm.nhs.uk [North West Lung Research Centre, University Hospital of South Manchester, Southmoor Road, Manchester M23 9LT (United Kingdom); Young, Simon S., E-mail: Simon.Young1@astrazeneca.com [Personalised Healthcare and Biomarkers, AstraZeneca R and D, Alderley Park, Macclesfield SK10 4TF (United Kingdom); Liu, Yu-Zhen, E-mail: yu-zhen.liu@astrazeneca.com [Personalised Healthcare and Biomarkers, AstraZeneca R and D, Alderley Park, Macclesfield SK10 4TF (United Kingdom); Parker, Geoffrey J.M., E-mail: Geoff.parker@manchester.ac.uk [Centre for Imaging Sciences, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom); Biomedical Imaging Institute, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom); Bioxydyn Limited, Rutherford House, Pencroft Way, Manchester M15 6SZ (United Kingdom); Naish, Josephine H., E-mail: Josephine.naish@manchester.ac.uk [Centre for Imaging Sciences, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom); Biomedical Imaging Institute, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom)

    2015-02-15

    Highlights: • Oxygen-enhanced MRI may have a role in the estimation of disease severity in asthma. • Heterogeneity of parameter maps reflects localized functional impairment in asthma. • OE-MRI provides non-ionising, spatial and temporal information on oxygen delivery. - Abstract: Objectives: To prospectively estimate the feasibility and reproducibility of dynamic oxygen-enhanced magnetic resonance imaging (OE-MRI) in the assessment of regional oxygen delivery, uptake and washout in asthmatic lungs. Materials and methods: The study was approved by the National Research Ethics Committee and written informed consent was obtained. Dynamic OE-MRI was performed twice at one month apart on four mild asthmatic patients (23 ± 5 years old, FEV{sub 1} = 96 ± 3% of predicted value) and six severe asthmatic patients (41 ± 12 years old, FEV{sub 1} = 60 ± 14% of predicted value) on a 1.5 T MR scanner using a two-dimensional T{sub 1}-weighted inversion-recovery turbo spin echo sequence. The enhancing fraction (EF), the maximal change in the partial pressure of oxygen in lung tissue (ΔPO{sub 2max{sub l}}) and arterial blood of the aorta (ΔPO{sub 2max{sub a}}), and the oxygen wash-in (τ{sub up{sub l}}, τ{sub up{sub a}}) and wash-out (τ{sub down{sub l}}, τ{sub down{sub a}}) time constants were extracted and compared between groups using the independent-samples t-test (two-tailed). Correlations between imaging readouts and clinical measurements were assessed by Pearson's correlation analysis. Bland–Altman analysis was used to estimate the levels of agreement between the repeat scans and the intra-observer agreement in the MR imaging readouts. Results: The severe asthmatic group had significantly smaller EF (70 ± 16%) and median ΔPO{sub 2max{sub l}} (156 ± 52 mmHg) and significantly larger interquartile range of τ{sub up{sub l}} (0.84 ± 0.26 min) than the mild asthmatic group (95 ± 3%, P = 0.014; 281 ± 40 mmHg, P = 0.004; 0.20 ± 0.07 min, P = 0

  8. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  9. Nuclear imaging of the fuel assembly in ignition experiments

    Energy Technology Data Exchange (ETDEWEB)

    Grim, G. P.; Guler, N.; Merrill, F. E.; Morgan, G. L.; Danly, C. R.; Volegov, P. L.; Wilde, C. H.; Wilson, D. C.; Clark, D. S.; Hinkel, D. E.; Jones, O. S.; Raman, K. S.; Izumi, N.; Fittinghoff, D. N.; Drury, O. B.; Alger, E. T.; Arnold, P. A.; Ashabranner, R. C.; Atherton, L. J.; Barrios, M. A.; Batha, S.; Bell, P. M.; Benedetti, L. R.; Berger, R. L.; Bernstein, L. A.; Berzins, L. V.; Betti, R.; Bhandarkar, S. D.; Bionta, R. M.; Bleuel, D. L.; Boehly, T. R.; Bond, E. J.; Bowers, M. W.; Bradley, D. K.; Brunton, G. K.; Buckles, R. A.; Burkhart, S. C.; Burr, R. F.; Caggiano, J. A.; Callahan, D. A.; Casey, D. T.; Castro, C.; Celliers, P. M.; Cerjan, C. J.; Chandler, G. A.; Choate, C.; Cohen, S. J.; Collins, G. W.; Cooper, G. W.; Cox, J. R.; Cradick, J. R.; Datte, P. S.; Dewald, E. L.; Di Nicola, P.; Di Nicola, J. M.; Divol, L.; Dixit, S. N.; Dylla-Spears, R.; Dzenitis, E. G.; Eckart, M. J.; Eder, D. C.; Edgell, D. H.; Edwards, M. J.; Eggert, J. H.; Ehrlich, R. B.; Erbert, G. V.; Fair, J.; Farley, D. R.; Felker, B.; Fortner, R. J.; Frenje, J. A.; Frieders, G.; Friedrich, S.; Gatu-Johnson, M.; Gibson, C. R.; Giraldez, E.; Glebov, V. Y.; Glenn, S. M.; Glenzer, S. H.; Gururangan, G.; Haan, S. W.; Hahn, K. D.; Hammel, B. A.; Hamza, A. V.; Hartouni, E. P.; Hatarik, R.; Hatchett, S. P.; Haynam, C.; Hermann, M. R.; Herrmann, H. W.; Hicks, D. G.; Holder, J. P.; Holunga, D. M.; Horner, J. B.; Hsing, W. W.; Huang, H.; Jackson, M. C.; Jancaitis, K. S.; Kalantar, D. H.; Kauffman, R. L.; Kauffman, M. I.; Khan, S. F.; Kilkenny, J. D.; Kimbrough, J. R.; Kirkwood, R.; Kline, J. L.; Knauer, J. P.; Knittel, K. M.; Koch, J. A.; Kohut, T. R.; Kozioziemski, B. J.; Krauter, K.; Krauter, G. W.; Kritcher, A. L.; Kroll, J.; Kyrala, G. A.; Fortune, K. N. La; LaCaille, G.; Lagin, L. J.; Land, T. A.; Landen, O. L.; Larson, D. W.; Latray, D. A.; Leeper, R. J.; Lewis, T. L.; LePape, S.; Lindl, J. D.; Lowe-Webb, R. R.; Ma, T.; MacGowan, B. J.; MacKinnon, A. J.; MacPhee, A. G.; Malone, R. M.; Malsbury, T. N.; Mapoles, E.; Marshall, C. D.; Mathisen, D. G.; McKenty, P.; McNaney, J. M.; Meezan, N. B.; Michel, P.; Milovich, J. L.; Moody, J. D.; Moore, A. S.; Moran, M. J.; Moreno, K.; Moses, E. I.; Munro, D. H.; Nathan, B. R.; Nelson, A. J.; Nikroo, A.; Olson, R. E.; Orth, C.; Pak, A. E.; Palma, E. S.; Parham, T. G.; Patel, P. K.; Patterson, R. W.; Petrasso, R. D.; Prasad, R.; Ralph, J. E.; Regan, S. P.; Rinderknecht, H.; Robey, H. F.; Ross, G. F.; Ruiz, C. L.; Seguin, F. H.; Salmonson, J. D.; Sangster, T. C.; Sater, J. D.; Saunders, R. L.; Schneider, M. B.; Schneider, D. H.; Shaw, M. J.; Simanovskaia, N.; Spears, B. K.; Springer, P. T.; Stoeckl, C.; Stoeffl, W.; Suter, L. J.; Thomas, C. A.; Tommasini, R.; Town, R. P.; Traille, A. J.; Wonterghem, B. Van; Wallace, R. J.; Weaver, S.; Weber, S. V.; Wegner, P. J.; Whitman, P. K.; Widmann, K.; Widmayer, C. C.; Wood, R. D.; Young, B. K.; Zacharias, R. A.; Zylstra, A.

    2013-05-01

    First results from the analysis of neutron image data collected on implosions of cryogenically layered deuterium-tritium capsules during the 2011-2012 National Ignition Campaign are reported. The data span a variety of experimental designs aimed at increasing the stagnation pressure of the central hotspot and areal density of the surrounding fuel assembly. Images of neutrons produced by deuterium–tritium fusion reactions in the hotspot are presented, as well as images of neutrons that scatter in the surrounding dense fuel assembly. The image data are compared with 1D and 2D model predictions, and consistency checked using other diagnostic data. The results indicate that the size of the fusing hotspot is consistent with the model predictions, as well as other imaging data, while the overall size of the fuel assembly, inferred from the scattered neutron images, is systematically smaller than models’ prediction. Preliminary studies indicate these differences are consistent with a significant fraction (20%–25%) of the initial deuterium-tritium fuel mass outside the compact fuel assembly, due either to low mode mass asymmetry or high mode 3D mix effects at the ablator-ice interface.

  10. Nuclear imaging of the fuel assembly in ignition experiments

    Energy Technology Data Exchange (ETDEWEB)

    Grim, G. P.; Guler, N.; Merrill, F. E.; Morgan, G. L.; Danly, C. R.; Volegov, P. L.; Wilde, C. H.; Wilson, D. C.; Batha, S.; Herrmann, H. W.; Kline, J. L.; Kyrala, G. A. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Clark, D. S.; Hinkel, D. E.; Jones, O. S.; Raman, K. S.; Izumi, N.; Fittinghoff, D. N.; Drury, O. B.; Alger, E. T. [Lawrence Livermore National Laboratory, Livermore, California 94551-0808 (United States); and others

    2013-05-15

    First results from the analysis of neutron image data collected on implosions of cryogenically layered deuterium-tritium capsules during the 2011-2012 National Ignition Campaign are reported. The data span a variety of experimental designs aimed at increasing the stagnation pressure of the central hotspot and areal density of the surrounding fuel assembly. Images of neutrons produced by deuterium–tritium fusion reactions in the hotspot are presented, as well as images of neutrons that scatter in the surrounding dense fuel assembly. The image data are compared with 1D and 2D model predictions, and consistency checked using other diagnostic data. The results indicate that the size of the fusing hotspot is consistent with the model predictions, as well as other imaging data, while the overall size of the fuel assembly, inferred from the scattered neutron images, is systematically smaller than models' prediction. Preliminary studies indicate these differences are consistent with a significant fraction (20%–25%) of the initial deuterium-tritium fuel mass outside the compact fuel assembly, due either to low mode mass asymmetry or high mode 3D mix effects at the ablator-ice interface.

  11. HDR brachytherapy in carcinoma of cervix: initial experience at AWARE hospitals

    International Nuclear Information System (INIS)

    Rajendran, M.; Reddy, K.D.; Reddy, R.M.; Reddy, J.M.; Reddy, B.V.N.; Kiran Kumar; Gopi, S.; Dharaniraj; Janardhanan

    2002-01-01

    High dose rate (HDR) brachytherapy is well established in the management of gynaecological malignancies. A report on the initial results of one and half year experience with a consistent dose/fractionation schedule and procedure of planning with delivery of treatment schedule is presented

  12. Preliminary Experience with Small Animal SPECT Imaging on Clinical Gamma Cameras

    Directory of Open Access Journals (Sweden)

    P. Aguiar

    2014-01-01

    Full Text Available The traditional lack of techniques suitable for in vivo imaging has induced a great interest in molecular imaging for preclinical research. Nevertheless, its use spreads slowly due to the difficulties in justifying the high cost of the current dedicated preclinical scanners. An alternative for lowering the costs is to repurpose old clinical gamma cameras to be used for preclinical imaging. In this paper we assess the performance of a portable device, that is, working coupled to a single-head clinical gamma camera, and we present our preliminary experience in several small animal applications. Our findings, based on phantom experiments and animal studies, provided an image quality, in terms of contrast-noise trade-off, comparable to dedicated preclinical pinhole-based scanners. We feel that our portable device offers an opportunity for recycling the widespread availability of clinical gamma cameras in nuclear medicine departments to be used in small animal SPECT imaging and we hope that it can contribute to spreading the use of preclinical imaging within institutions on tight budgets.

  13. Assessment of regional lung functional impairment with co-registered respiratory-gated ventilation/perfusion SPET-CT images: initial experiences

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Zaki, Mohammed; Yamashita, Tomio; Seto, Aska; Matsumoto, Tsuneo; Matsunaga, Naofumi

    2004-01-01

    In this study, respiratory-gated ventilation and perfusion single-photon emission tomography (SPET) were used to define regional functional impairment and to obtain reliable co-registration with computed tomography (CT) images in various lung diseases. Using a triple-headed SPET unit and a physiological synchroniser, gated perfusion SPET was performed in a total of 78 patients with different pulmonary diseases, including metastatic nodules (n=15); in 34 of these patients, it was performed in combination with gated technetium-99m Technegas SPET. Projection data were acquired using 60 stops over 120 for each detector. Gated end-inspiration and ungated images were reconstructed from 1/8 data centered at peak inspiration for each regular respiratory cycle and full respiratory cycle data, respectively. Gated images were registered with tidal inspiration CT images using automated three-dimensional (3D) registration software. Registration mismatch was assessed by measuring 3D distance of the centroid of the nine selected round perfusion-defective nodules. Gated SPET images were completed within 29 min, and increased the number of visible ventilation and perfusion defects by 9.7% and 17.2%, respectively, as compared with ungated images; furthermore, lesion-to-normal lung contrast was significantly higher on gated SPET images. In the nine round perfusion-defective nodules, gated images yielded a significantly better SPET-CT match compared with ungated images (4.9±3.1 mm vs 19.0±9.1 mm, P<0.001). The co-registered SPET-CT images allowed accurate perception of the location and extent of each ventilation/perfusion defect on the underlying CT anatomy, and characterised the pathophysiology of the various diseases. By reducing respiratory motion effects and enhancing perfusion/ventilation defect clarity, gated SPET can provide reliable co-registered images with CT images to accurately characterise regional functional impairment in various lung diseases. (orig.)

  14. Dual-energy CT in the evaluation of solitary pulmonary nodules by virtual non-enhanced images: initial experience

    International Nuclear Information System (INIS)

    Guo Xing; Ding Wei; Qin Huijuan

    2011-01-01

    Objective: To determine the accuracy and radiation dose of dual-energy computed tomography (CT) in evaluating solitary pulmonary nodules (SPNs) by virtual non-enhanced images. Methods: Sixty-one patients with SPNs including 39 malignant and 18 benign nodules proved by pathology underwent DECT scans. The CT values of SPNs on enhanced weighted average and virtual non-enhanced images were compared by using Liver VNC processing unit in terms of their diagnostic accuracy for distinguishing malignant and benign nodules with a 20 HU threshold. Diagnostic accuracy was compared. In 28 patients of all patients, image noise and quality score of the non-enhanced and virtual non-enhanced images were compared, and radiation doses of each patient were recorded. The paired t test was used to analyze the noise difference between the plain scan and virtual non-enhanced scan. The Mann-Whitney U test. was used to analyze statistically significant differences of the image quality score and radiation dose between the non-enhanced scan and virtual non-enhanced scan. Results: The sensitivity, specificity and accuracy for distinguishing benign and malignant nodules by using the virtual non-enhanced image of were 89.7% (35/39), 72.2% (13/18), 84.2% (48/57) respectively. The noise of common CT and virtual non- enhanced images were (8.49±1.94) HU and (10.14±2.18) HU, and there were statistically difference (t=9.45, P 0.05). The radiation doses of common CT and DECT were (3.72±0.48) mSv and (3.78±0.45) mSv, and there were no statistical difference (U= 350.50, P>0.05). Conclusion: DECT by using virtual non-enhanced images is useful tool to distinguish the benign and malignant SPN without additional radiation dose. (authors)

  15. SU-E-E-05: Initial Experience On Physics Rotation of Radiological Residents

    International Nuclear Information System (INIS)

    Zhang, J; Williams, D; DiSantis, D; Hardy, P; Oates, M

    2014-01-01

    Purpose: The new ABR core exam integrates physics into clinical teaching, with an emphasis on understanding image quality, image artifacts, radiation dose and patient safety for each modality and/or sub-specialty. Accordingly, physics training of radiological residents faces a challenge. A traditional teaching of physics through didactic lectures may not fully fulfill this goal. It is also difficult to incorporate physics teaching in clinical practice due to time constraints. A dedicated physics rotation may be a solution. This study is to evaluate a full week physics workshop developed for the first year radiological residents. Methods: The physics rotation took a full week. It included three major parts, introduction lectures, hand-on experiences and observation of technologist operation. An introduction of basic concepts was given to each modality at the beginning. Hand-on experiments were emphasized and took most of time. During hand-on experiments, residents performed radiation measurements, studied the relationship between patient dose and practice (i.e., fluoroscopy), investigated influence of acquisition parameters (i.g., kV, mAs) on image quality, and evaluated image quality using phantoms A physics test before and after the workshop was also given but not for comparison purpose. Results: The evaluation shows that the physics rotation during the first week of residency in radiology is preferred by all residents. The length of a full week of physics workshop is appropriate. All residents think that the intensive workshop can significantly benefit their coming clinical rotations. Residents become more comfortable regarding the use of radiation and counseling relevant questions such as a pregnant patient risk from a CE PE examination. Conclusion: A dedicated physics rotation, assisting with didactic lectures, may fulfill the requirements of physics of the new ABR core exam. It helps radiologists deeply understand the physics concepts and more efficiently use

  16. SU-E-E-05: Initial Experience On Physics Rotation of Radiological Residents

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, J; Williams, D; DiSantis, D; Hardy, P; Oates, M [University of Kentucky, Lexington, KY (United States)

    2014-06-01

    Purpose: The new ABR core exam integrates physics into clinical teaching, with an emphasis on understanding image quality, image artifacts, radiation dose and patient safety for each modality and/or sub-specialty. Accordingly, physics training of radiological residents faces a challenge. A traditional teaching of physics through didactic lectures may not fully fulfill this goal. It is also difficult to incorporate physics teaching in clinical practice due to time constraints. A dedicated physics rotation may be a solution. This study is to evaluate a full week physics workshop developed for the first year radiological residents. Methods: The physics rotation took a full week. It included three major parts, introduction lectures, hand-on experiences and observation of technologist operation. An introduction of basic concepts was given to each modality at the beginning. Hand-on experiments were emphasized and took most of time. During hand-on experiments, residents performed radiation measurements, studied the relationship between patient dose and practice (i.e., fluoroscopy), investigated influence of acquisition parameters (i.g., kV, mAs) on image quality, and evaluated image quality using phantoms A physics test before and after the workshop was also given but not for comparison purpose. Results: The evaluation shows that the physics rotation during the first week of residency in radiology is preferred by all residents. The length of a full week of physics workshop is appropriate. All residents think that the intensive workshop can significantly benefit their coming clinical rotations. Residents become more comfortable regarding the use of radiation and counseling relevant questions such as a pregnant patient risk from a CE PE examination. Conclusion: A dedicated physics rotation, assisting with didactic lectures, may fulfill the requirements of physics of the new ABR core exam. It helps radiologists deeply understand the physics concepts and more efficiently use

  17. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): A Completed Reference Database of Lung Nodules on CT Scans

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-02-15

    Purpose: The development of computer-aided diagnostic (CAD) methods for lung nodule detection, classification, and quantitative assessment can be facilitated through a well-characterized repository of computed tomography (CT) scans. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI) completed such a database, establishing a publicly available reference for the medical imaging research community. Initiated by the National Cancer Institute (NCI), further advanced by the Foundation for the National Institutes of Health (FNIH), and accompanied by the Food and Drug Administration (FDA) through active participation, this public-private partnership demonstrates the success of a consortium founded on a consensus-based process. Methods: Seven academic centers and eight medical imaging companies collaborated to identify, address, and resolve challenging organizational, technical, and clinical issues to provide a solid foundation for a robust database. The LIDC/IDRI Database contains 1018 cases, each of which includes images from a clinical thoracic CT scan and an associated XML file that records the results of a two-phase image annotation process performed by four experienced thoracic radiologists. In the initial blinded-read phase, each radiologist independently reviewed each CT scan and marked lesions belonging to one of three categories (''nodule{>=}3 mm,''''nodule<3 mm,'' and ''non-nodule{>=}3 mm''). In the subsequent unblinded-read phase, each radiologist independently reviewed their own marks along with the anonymized marks of the three other radiologists to render a final opinion. The goal of this process was to identify as completely as possible all lung nodules in each CT scan without requiring forced consensus. Results: The Database contains 7371 lesions marked ''nodule'' by at least one radiologist. 2669 of these lesions were marked &apos

  18. Contrast-enhanced magnetic resonance imaging of the breast: the value of pharmacokinetic parameters derived from fast dynamic imaging during initial enhancement in classifying lesions

    International Nuclear Information System (INIS)

    Veltman, J.; Stoutjesdijk, M.; Mann, R.; Huisman, H.J.; Barentsz, J.O.; Blickman, J.G.; Boetes, C.

    2008-01-01

    The value of pharmacokinetic parameters derived from fast dynamic imaging during initial enhancement in characterizing breast lesions on magnetic resonance imaging (MRI) was evaluated. Sixty-eight malignant and 34 benign lesions were included. In the scanning protocol, high temporal resolution imaging was combined with high spatial resolution imaging. The high temporal resolution images were recorded every 4.1 s during initial enhancement (fast dynamic analysis). The high spatial resolution images were recorded at a temporal resolution of 86 s (slow dynamic analysis). In the fast dynamic evaluation pharmacokinetic parameters (K trans , V e and k ep ) were evaluated. In the slow dynamic analysis, each lesion was scored according to the BI-RADS classification. Two readers evaluated all data prospectively. ROC and multivariate analysis were performed. The slow dynamic analysis resulted in an AUC of 0.85 and 0.83, respectively. The fast dynamic analysis resulted in an AUC of 0.83 in both readers. The combination of both the slow and fast dynamic analyses resulted in a significant improvement of diagnostic performance with an AUC of 0.93 and 0.90 (P = 0.02). The increased diagnostic performance found when combining both methods demonstrates the additional value of our method in further improving the diagnostic performance of breast MRI. (orig.)

  19. The patient experience of high technology medical imaging: A systematic review of the qualitative evidence

    International Nuclear Information System (INIS)

    Munn, Zachary; Jordan, Zoe

    2011-01-01

    Background: When presenting to an imaging department, the person who is to be imaged is often in a vulnerable state, and can experience the scan in a number of ways. It is the role of the radiographer to produce a high quality image and facilitate patient care throughout the imaging process. A qualitative systematic review was performed to synthesise the existent evidence on the patient experience of high technology medical imaging. Only papers relating to Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) were identified. Inclusion criteria: Studies that were of a qualitative design that explored the phenomenon of interest, the patient experience of high technology medical imaging. Participants included anyone who had undergone one of these procedures. Methods: A systematic search of medical and allied health databases was conducted. Articles identified during the search process that met the inclusion criteria were then critically appraised for methodological quality independently by two reviewers. Results: During the search and inclusion process, 15 studies were found that were deemed of suitable quality to be included in the review. From the 15 studies, 127 findings were extracted from the included studies. These were analysed in more detail to observe common themes, and then grouped into 33 categories. From these 33 categories, 11 synthesised findings were produced. The 11 synthesised findings highlight the diverse, unique and challenging ways in which people experience imaging with MRI and CT scanners. Conclusion: The results of the review demonstrate the diverse ways in which people experience medical imaging. All health professionals involved in imaging need to be aware of the different ways each patient may experience imaging.

  20. Basic principles of magnetic resonance imaging in cerebral ischemia and initial clinical experience

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Solomon, M.; Newton, T.H.; Weinstein, P.; Schmidley, J.; Norman, D.

    1985-01-01

    NMR tomography proved to be a method superior to computerized tomography (CT) in terms of sensitivity in the diagnosis of pathological changes in the brain. The article on hand gives a brief survey on the principle of the method and demonstrates the superiority of NMR tomography to CT exemplified by images taken from a number of cases. Instrumental factors influencing diagnosis of cerebral ischaemie are discussed. Clinical studies performed on more than 20 partients with suspected infarct revealed the superiority of NMR tomography to CT. (MG) [de

  1. Myocardial delayed-enhancement CT: initial experience in children and young adults

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2017-10-15

    Clinical utility of myocardial delayed enhancement CT has not been reported in children and young adults. To describe initial experience of myocardial delayed enhancement CT regarding image quality, radiation dose and identification of myocardial lesions in children and young adults. Between August 2013 and November 2016, 29 consecutive children and young adults (median age 16 months) with suspected coronary artery or myocardial abnormality underwent arterial- and delayed-phase cardiac CT at our institution. We measured CT densities in normal myocardium, left ventricular cavity, and arterial and delayed hypo-enhancing and delayed hyperenhancing myocardial lesions. We then compared the extent of delayed hyperenhancing lesions with delayed-enhancement MRI or thallium single-photon emission CT. Normal myocardium and left ventricular cavity showed significantly higher CT numbers on arterial-phase CT than on delayed-phase CT (t-test, P<0.0001). Contrast-to-noise ratios of the arterial and delayed hypo-enhancing and delayed hyperenhancing lesions on CT were 26.7, 17.6 and 18.7, respectively. Delayed-phase CT findings were equivalent to those of delayed-enhancement MRI in all cases (7/7) and to those of thallium single-photon emission CT in 70% (7/10). Myocardial delayed-enhancement CT can be added to evaluate myocardial lesions in select children and young adults with suspected coronary artery or myocardial abnormality. (orig.)

  2. Myocardial delayed-enhancement CT: initial experience in children and young adults

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2017-01-01

    Clinical utility of myocardial delayed enhancement CT has not been reported in children and young adults. To describe initial experience of myocardial delayed enhancement CT regarding image quality, radiation dose and identification of myocardial lesions in children and young adults. Between August 2013 and November 2016, 29 consecutive children and young adults (median age 16 months) with suspected coronary artery or myocardial abnormality underwent arterial- and delayed-phase cardiac CT at our institution. We measured CT densities in normal myocardium, left ventricular cavity, and arterial and delayed hypo-enhancing and delayed hyperenhancing myocardial lesions. We then compared the extent of delayed hyperenhancing lesions with delayed-enhancement MRI or thallium single-photon emission CT. Normal myocardium and left ventricular cavity showed significantly higher CT numbers on arterial-phase CT than on delayed-phase CT (t-test, P<0.0001). Contrast-to-noise ratios of the arterial and delayed hypo-enhancing and delayed hyperenhancing lesions on CT were 26.7, 17.6 and 18.7, respectively. Delayed-phase CT findings were equivalent to those of delayed-enhancement MRI in all cases (7/7) and to those of thallium single-photon emission CT in 70% (7/10). Myocardial delayed-enhancement CT can be added to evaluate myocardial lesions in select children and young adults with suspected coronary artery or myocardial abnormality. (orig.)

  3. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    International Nuclear Information System (INIS)

    Gaona, Enrique; Enriquez, Jesus Gabriel Franco; Alfonso, Beatriz Y. Alvarez; Castellanos, Gustavo Casian

    2008-01-01

    The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography

  4. High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography - initial experience

    International Nuclear Information System (INIS)

    Rist, Carsten; Nikolaou, Konstantin; Wintersperger, Bernd J.; Reiser, Maximilian F.; Becker, Christoph R.; Flohr, Thomas

    2006-01-01

    The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265±25HU and 254±16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367±36HU versus 402±28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68±0.08 mm versus 2.81±0.07 mm and 3.29±0.06 mm versus 3.18±0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen. (orig.)

  5. Commissioning and initial experimental program of the BGO-OD experiment at ELSA

    Science.gov (United States)

    Alef, S.; Bauer, P.; Bayadilov, D.; Beck, R.; Becker, M.; Bella, A.; Bielefeldt, P.; Böse, S.; Braghieri, A.; Brinkmann, K.; Cole, P.; Di Salvo, R.; Dutz, H.; Elsner, D.; Fantini, A.; Freyermuth, O.; Friedrich, S.; Frommberger, F.; Ganenko, V.; Geffers, D.; Gervino, G.; Ghio, F.; Görtz, S.; Gridnev, A.; Gutz, E.; Hammann, D.; Hannappel, J.; Hillert, W.; Ignatov, A.; Jahn, R.; Joosten, R.; Jude, T. C.; Klein, F.; Knaust, J.; Kohl, K.; Koop, K.; Krusche, B.; Lapik, A.; Levi Sandri, P.; Lopatin, I. V.; Mandaglio, G.; Messi, F.; Messi, R.; Metag, V.; Moricciani, D.; Mushkarenkov, A.; Nanova, M.; Nedorezov, V.; Novinskiy, D.; Pedroni, P.; Reitz, B.; Romaniuk, M.; Rostomyan, T.; Rudnev, N.; Schaerf, C.; Scheluchin, G.; Schmieden, H.; Stugelev, A.; Sumachev, V.; Tarakanov, V.; Vegna, V.; Walther, D.; Watts, D.; Zaunick, H.; Zimmermann, T.

    2016-11-01

    BGO-OD is a new meson photoproduction experiment at the ELSA facility of Bonn University. It aims at the investigation of non strange and strange baryon excitations, and is especially designed to be able to detect weekly bound meson-baryon type structures. The setup for the BGO-OD experiment is presented, the characteristics of the photon beam and the detector performances are shown and the initial experimental program is discussed.

  6. How does arm positioning of polytraumatized patients in the initial computed tomography (CT) affect image quality and diagnostic accuracy?

    International Nuclear Information System (INIS)

    Kahn, Johannes; Grupp, Ulrich; Maurer, Martin

    2014-01-01

    Purpose: To evaluate the influence of different arm positions on abdominal image quality during initial whole-body CT (WBCT) in polytraumatized patients and to assess the risk of missing potentially life-threatening injuries due to arm artifacts. Materials and methods: Between July 2011 and February 2013, WBCT scans of 203 patients with arms in the abdominal area during initial WBCT were analyzed. Six different arms-down positions were defined: patients with both (group A)/one arm(s) (group B) down alongside the torso, patients with both (group C)/one arm(s) (group D) crossed in front of the upper abdomen, patients with both (group E)/one arm(s) (group F) crossed in front of the pelvic area. A group of 203 patients with elevated arms beside the head served as a control group. Two observers jointly evaluated image quality of different organ regions using a 4-point scale system. Follow-up examinations (CT scans and/or ultrasound) were analyzed to identify findings missed during initial WBCT due to reduced image quality. Results: Image quality for most of the organ regions analyzed was found to be significantly different among all groups (p < 0.05). Image quality was most severely degraded in group A, followed by groups E and C. Positioning with one arm up resulted in significantly better image quality than both arms down (p < 0.05). Overall, arms-up positioning showed significantly better image quality than arms-down positions (p < 0.05). In one case, liver hemorrhage missed in the initial WBCT because of arm artifacts, was revealed by follow-up CT. Conclusion: In WBCT arms-down positioning significantly degrades abdominal image quality and artifacts might even conceal potentially life-threatening injuries. If the patient's status does not allow elevation of both arms, image quality can benefit from raising at least one arm. Otherwise, arms should be placed in front of the upper abdomen instead of alongside the torso

  7. Teleradiology service for mission hospitals: initial experiences in Ethiopia and Kenya

    Directory of Open Access Journals (Sweden)

    Matthew Larrison

    2016-01-01

    Full Text Available Throughout their history, mission hospitals have provided high quality and lifesaving medical care to regions of the world where medical care is sparse. These hospitals are generally built and equipped through a combination of governmental and non-governmental sources. As advances in diagnostic medical imaging have progressed and become mainstream in the developed world, mission hospitals have adopted advanced imaging modalities. These modalities provide early diagnosis and treatment options for their patients. In addition to the installation and operation of advanced imaging equipment, the need for professional expert interpretation of these studies remains a challenge for mission hospitals. Historically these hospitals have used either voluntary services on site or paid for interpretations from local radiologists; however, with the introduction of high speed internet, teleradiology has become a possibility. This article describes the teleradiology experience of two mission hospitals in rural Africa.

  8. Studying a free fall experiment using short sequences of images

    International Nuclear Information System (INIS)

    Vera, Francisco; Romanque, Cristian

    2008-01-01

    We discuss a new alternative for obtaining position and time coordinates from a video of a free fall experiment. In our approach, after converting the video to a short sequence of images, the images are analyzed using a web page application developed by the author. The main advantage of the setup explained in this work, is that it is simple to use, no software license fees are necessary, and can be scaled-up to be used by a big number of students in introductory physics courses. The steps involved in the full analysis of a falling object are: we grab a short digital video of the experiment and convert it to a sequence of images, then, using a web page that includes all the necessary javascript, the student can easily click on the object of interest to obtain the (x,y,t) coordinates, finally, the student analyze motion using a spreadsheet.

  9. Initial experience of tritium exposure control at JET

    International Nuclear Information System (INIS)

    Patel, B.; Campling, D.C.; Schofield, P.A.; Macheta, P.; Sandland, K.

    1998-01-01

    Some of the safety procedures and controls in place for work with tritium are described, and initial operational experience of handling tritium is discussed. A description is given of work to rectify a water leak in a JET neutral beam heating component, which involved man-access to a confined volume to perform repairs, at tritium levels about 100 DAC (80 MBq/m 3 . HTO). Control measures involving use of purge and extract ventilation, and of personal protection using air-fed pressurized suits are described. Results are given of the internal doses to project staff and of atmospheric discharges of tritium during the repair outage. (P.A.)

  10. The Image of Mathematics Held by Irish Post-Primary Students

    Science.gov (United States)

    Lane, Ciara; Stynes, Martin; O'Donoghue, John

    2014-01-01

    The image of mathematics held by Irish post-primary students was examined and a model for the image found was constructed. Initially, a definition for "image of mathematics" was adopted with image of mathematics hypothesized as comprising attitudes, beliefs, self-concept, motivation, emotions and past experiences of mathematics. Research…

  11. Initial experience with robotic pancreatic surgery in Singapore: single institution experience with 30 consecutive cases.

    Science.gov (United States)

    Goh, Brian K P; Low, Tze-Yi; Lee, Ser-Yee; Chan, Chung-Yip; Chung, Alexander Y F; Ooi, London L P J

    2018-05-24

    Presently, the worldwide experience with robotic pancreatic surgery (RPS) is increasing although widespread adoption remains limited. In this study, we report our initial experience with RPS. This is a retrospective review of a single institution prospective database of 72 consecutive robotic hepatopancreatobiliary surgeries performed between 2013 and 2017. Of these, 30 patients who underwent RPS were included in this study of which 25 were performed by a single surgeon. The most common procedure was robotic distal pancreatectomy (RDP) which was performed in 20 patients. This included eight subtotal pancreatectomies, two extended pancreatecto-splenectomies (en bloc gastric resection) and 10 spleen-saving-RDP. Splenic preservation was successful in 10/11 attempted spleen-saving-RDP. Eight patients underwent pancreaticoduodenectomies (five hybrid with open reconstruction), one patient underwent a modified Puestow procedure and one enucleation of uncinate tumour. Four patients had extended resections including two RDP with gastric resection and two pancreaticoduodenectomies with vascular resection. There was one (3.3%) open conversion and seven (23.3%) major (>Grade II) morbidities. Overall, there were four (13.3%) clinically significant (Grade B) pancreatic fistulas of which three required percutaneous drainage. These occurred after three RDP and one robotic enucleation. There was one reoperation for port-site hernia and no 30-day/in-hospital mortalities. The median post-operative stay was 6.5 (range: 3-36) days and there were six (20%) 30-day readmissions. Our initial experience showed that RPS can be adopted safely with a low open conversion rate for a wide variety of procedures including pancreaticoduodenectomy. © 2018 Royal Australasian College of Surgeons.

  12. Initial magnetic field decay of the superconducting magnet in persistent current mode

    International Nuclear Information System (INIS)

    Yamamoto, S.; Yanada, T.

    1988-01-01

    The initial magnetic field decay in the persistent current mode of a magnetic resonance imaging magnet has been studied experimentally. The field decay is greater than the steady field decay due to joint resistances of conductors. Imaging experiments cannot be carried out during the periods, which last ten or more hours. The current distribution in the multifilamentory conductor is non-uniform just after the energization. It is suggested that the change of the current distribution causes the initial magnetic field decay. A 6th order superconducting magnet was prepared for experiments (central field = 0.35 T, inner diameters = 1 m, length = 1.86 m). The steady state magnetic field decay was 7*10/sup -8//hr. The initial magnetic field decay was 3*10/sup -6//hr. Overshoot currents (101 and 105 percent of the rated current) were applied to the magnet and the current reduced to the rated current to improve the initial decay. The energizing and de-energizing rate of the field was 1.8 gauss/second. No initial decay was observed when 105 percent current pattern was applied to the magnet

  13. Criteria for applying imaging diagnosis and initial management for pediatric head trauma

    International Nuclear Information System (INIS)

    Shiomi, Naoto; Okada, Michiko; Echigo, Tadashi; Oka, Hideki; Hino, Akihiko

    2010-01-01

    It may be difficult to perform CT for pediatric head trauma because of body movement and radiation exposure. Imaging application criteria were established, in which patients diagnosed as less likely to have an intracranial lesion meeting the criteria were not indicated for imaging and subjected to course observation at home, and this policy was explained to the parents. When consent was obtained, patients were followed up at home, and we checked on the condition by making a phone call 4-8 hours after injury. The patients were 103 infants aged 15 years or younger brought to the emergency medical care center of our hospital between May and August 2008. Imaging was basically indicated for cases of traffic accidents, falls from a high level, those brought in by ambulance, referred cases, and cases with disturbance of consciousness, neurologically abnormal findings, vomiting on examination, and trauma requiring X-ray examination in addition to that for the head. However, apart from these cases, imaging was not required. Imaging was not necessary for 94% of infant cases. The parents were convinced by the explanation and selected course observation at home in 94% of cases for which imaging was judged as unnecessary. None of the patients required re-examination based on the conditions reported in phone calls to homes. Imaging diagnosis for pediatric head trauma is not always necessary, and its application should be decided on after consultation. When no imaging is performed, this should be fully explained at the initial treatment before selecting course observation at home. Checking on the child's condition by making a phone call several hours after injury is useful for both patients and physicians. (author)

  14. Automatic localization of landmark sets in head CT images with regression forests for image registration initialization

    Science.gov (United States)

    Zhang, Dongqing; Liu, Yuan; Noble, Jack H.; Dawant, Benoit M.

    2016-03-01

    Cochlear Implants (CIs) are electrode arrays that are surgically inserted into the cochlea. Individual contacts stimulate frequency-mapped nerve endings thus replacing the natural electro-mechanical transduction mechanism. CIs are programmed post-operatively by audiologists but this is currently done using behavioral tests without imaging information that permits relating electrode position to inner ear anatomy. We have recently developed a series of image processing steps that permit the segmentation of the inner ear anatomy and the localization of individual contacts. We have proposed a new programming strategy that uses this information and we have shown in a study with 68 participants that 78% of long term recipients preferred the programming parameters determined with this new strategy. A limiting factor to the large scale evaluation and deployment of our technique is the amount of user interaction still required in some of the steps used in our sequence of image processing algorithms. One such step is the rough registration of an atlas to target volumes prior to the use of automated intensity-based algorithms when the target volumes have very different fields of view and orientations. In this paper we propose a solution to this problem. It relies on a random forest-based approach to automatically localize a series of landmarks. Our results obtained from 83 images with 132 registration tasks show that automatic initialization of an intensity-based algorithm proves to be a reliable technique to replace the manual step.

  15. The Cortex Transform as an image preprocessor for sparse distributed memory: An initial study

    Science.gov (United States)

    Olshausen, Bruno; Watson, Andrew

    1990-01-01

    An experiment is described which was designed to evaluate the use of the Cortex Transform as an image processor for Sparse Distributed Memory (SDM). In the experiment, a set of images were injected with Gaussian noise, preprocessed with the Cortex Transform, and then encoded into bit patterns. The various spatial frequency bands of the Cortex Transform were encoded separately so that they could be evaluated based on their ability to properly cluster patterns belonging to the same class. The results of this study indicate that by simply encoding the low pass band of the Cortex Transform, a very suitable input representation for the SDM can be achieved.

  16. Computer assisted treatments for image pattern data of laser plasma experiments

    International Nuclear Information System (INIS)

    Yaoita, Akira; Matsushima, Isao

    1987-01-01

    An image data processing system for laser-plasma experiments has been constructed. These image data are two dimensional images taken by X-ray, UV, infrared and visible light television cameras and also taken by streak cameras. They are digitized by frame memories. The digitized image data are stored in disk memories with the aid of a microcomputer. The data are processed by a host computer and stored in the files of the host computer and on magnetic tapes. In this paper, the over view of the image data processing system and some software for data handling in the host computer are reported. (author)

  17. Initial patient imaging with an optimised radiotherapy beam for portal imaging

    International Nuclear Information System (INIS)

    Flampouri, Stella; McNair, Helen A.; Donovan, Ellen M.; Evans, Philip M.; Partridge, Mike; Verhaegen, Frank; Nutting, Christopher M.

    2005-01-01

    Background and purpose: To investigate the feasibility and the advantages of a portal-imaging mode on a medical accelerator, consisting of a thin low-Z bremsstrahlung target and a thin Gd 2 O 2 S/film detector, for patient imaging. Patients and methods: The international code of practice for high-energy photon dosimetry was used to calibrate dosimetry instruments for the imaging beam produced by 4.75 MeV electrons hitting a 6 mm thick aluminium target. Images of the head and neck of a humanoid phantom were taken with a mammography film system and the dose in the phantom was measured with TLDs calibrated for this beam. The first head and neck patient images are compared with conventional images (taken with the treatment beam on a film radiotherapy verification detector). Visibility of structures for six patients was evaluated. Results: Images of the head and neck of a humanoid phantom, taken with both imaging systems showed that the contrast increased dramatically for the new system while the dose required to form an image was less than 10 -2 Gy. The patient images taken with the new and the conventional systems showed that air-tissue interfaces were better defined in the new system image. Anatomical structures, visible on both films, are clearer with the new system. Additionally, bony structures, such as vertebrae, were clearly visible only with the new system. The system under evaluation was significantly better for all features in lateral images and most features in anterior images. Conclusions: This pilot study of the new portal imaging system showed the image quality is significantly improved

  18. The Relationship of a Pilot's Educational Background, Aeronautical Experience and Recency of Experience to Performance In Initial Training at a Regional Airline

    Science.gov (United States)

    Shane, Nancy R.

    The purpose of this study was to determine how a pilot's educational background, aeronautical experience and recency of experience relate to their performance during initial training at a regional airline. Results show that variables in pilots' educational background, aeronautical experience and recency of experience do predict performance in training. The most significant predictors include years since graduation from college, multi-engine time, total time and whether or not a pilot had military flying experience. Due to the pilot shortage, the pilots entering regional airline training classes since August 2013 have varied backgrounds, aeronautical experience and recency of experience. As explained by Edward Thorndike's law of exercise and the law of recency, pilots who are actively using their aeronautical knowledge and exercising their flying skills should exhibit strong performance in those areas and pilots who have not been actively using their aeronautical knowledge and exercising their flying skills should exhibit degraded performance in those areas. Through correlation, chi-square and multiple regression analysis, this study tests this theory as it relates to performance in initial training at a regional airline.

  19. Changing job seekers' image perceptions during recruitment visits: the moderating role of belief confidence.

    Science.gov (United States)

    Slaughter, Jerel E; Cable, Daniel M; Turban, Daniel B

    2014-11-01

    The purpose of this study was to understand how an important construct in social psychology-confidence in one's beliefs-could both (a) influence the effectiveness of organizations' recruiting processes and (b) be changed during recruitment. Using a sample of recruits to a branch of the United States military, the authors studied belief confidence before and after recruits' formal visits to the organization's recruiting stations. Personal sources of information had a stronger influence on recruits' belief confidence than impersonal sources. Moreover, recruits' confidence in their initial beliefs affected how perceptions of the recruiter changed their employer images. Among participants with low-initial confidence, the relation between recruitment experiences and employer images was positive and linear across the whole range of recruitment experiences. Among recruits with high-initial confidence, however, the recruitment experience-image relationship was curvilinear, such that recruitment experiences were related to images only at more positive recruitment experiences. The relationship between recruitment experiences and changes in belief confidence was also curvilinear, such that only more positive recruitment experiences led to changes in confidence. These results indicate not only that belief confidence influences the effectiveness of recruiting efforts but also that recruiting efforts can influence belief confidence. (PsycINFO Database Record (c) 2014 APA, all rights reserved).

  20. Optics for Advanced Neutron Imaging and Scattering

    International Nuclear Information System (INIS)

    Moncton, David E.; Khaykovich, Boris

    2016-01-01

    During the report period, we continued the work as outlined in the original proposal. We have analyzed potential optical designs of Wolter mirrors for the neutron-imaging instrument VENUS, which is under construction at SNS. In parallel, we have conducted the initial polarized imaging experiment at Helmholtz Zentrum, Berlin, one of very few of currently available polarized-imaging facilities worldwide.

  1. A Scheme for Initial Exploratory Data Analysis of Multivariate Image Data

    DEFF Research Database (Denmark)

    Hilger, Klaus Baggesen; Nielsen, Allan Aasbjerg; Larsen, Rasmus

    2001-01-01

    A new scheme is proposed for handling initial exploratory analyses of multivariate image data. The method is invariant to linear transformations of the original data and is useful for data fusion of multisource measurements. The scheme includes dimensionality reduction followed by unsupervised...... clustering of the data. A transformation is proposed which maximizes autocorrelation by projection onto subspaces with signal-to-noise ratio dependent variance. We apply the traditional fuzzy c-means algorithm and introduce two additional memberships enhancing the textural awareness of the algorithm. Cluster...

  2. Adoption of an integrated radiology reading room within a urologic oncology clinic: initial experience in facilitating clinician consultations.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Lepor, Herbert; Taneja, Samir S; Recht, Michael P

    2014-05-01

    The authors describe their initial experience in implementing an integrated radiology reading room within a urologic oncology clinic, including the frequency and nature of clinician consultations and the perceived impact on patient management by clinicians. A radiology reading room was established within an office-based urologic oncology clinic in proximity to the surgeon's work area. A radiologist was present in this reading room for a 3-hour shift each day. The frequency and nature of consultations during these shifts were recorded. Also, the clinic's staff completed a survey assessing perceptions of the impact of the integrated reading room on patient management. One hundred two consultations occurred during 57 included dates (average, 1.8 consultations per shift): 52% for review of external cases brought in by patients on discs, 43% for review of internal cases, and 5% for direct review by the radiologist of imaging with patients. The maximum number of consultations during a single shift was 8. All of the clinic's urologists indicated that >90% of consultations benefited patient care. The clinicians indicated tendencies to view consultations as affecting management in the majority of cases, to be more likely to seek consultation for outside imaging when the radiologist was on site, and to be less likely to repeat outside imaging when the radiologist was on site. The integrated reading room within the clinic has potential to improve the quality of care, for instance by facilitating increased review of outside imaging studies and thereby potentially reducing duplicate ordering and by enabling occasional direct image review with patients by radiologists. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. Initially curved microplates under electrostatic actuation: theory and experiment

    KAUST Repository

    Saghir, Shahid

    2016-07-01

    Microplates are the building blocks of many micro-electro-mechanical systems. It is common for them to experience initial curvature imperfection due to residual stresses caused by the micro fabrication process. Such plates are essentially different from perfectly flat ones and cannot be modeled using flat plate models. In this paper, we adopt a dynamic analog of the von Karman governing equations of imperfect plates. These equations are then used to develop a reduced order model based on the Galerkin procedure, to simulate the static and dynamic behavior of the microplate under electrostatic actuation. To validate the simulation results, an initially curved imperfect microplate made of silicon nitride is fabricated and tested. The static behaviour of the microplate is investigated when applying a DC voltage Vdc. Then, the dynamic behaviour of the microplate is examined under the application of a harmonic AC voltage, Vac, superimposed to Vdc. The simulation results show good agreement with the experimentally measured responses. © 2016 IOP Publishing Ltd.

  4. [Evaluation of the influence of humidity and temperature on the drug stability by initial average rate experiment].

    Science.gov (United States)

    He, Ning; Sun, Hechun; Dai, Miaomiao

    2014-05-01

    To evaluate the influence of temperature and humidity on the drug stability by initial average rate experiment, and to obtained the kinetic parameters. The effect of concentration error, drug degradation extent, humidity and temperature numbers, humidity and temperature range, and average humidity and temperature on the accuracy and precision of kinetic parameters in the initial average rate experiment was explored. The stability of vitamin C, as a solid state model, was investigated by an initial average rate experiment. Under the same experimental conditions, the kinetic parameters obtained from this proposed method were comparable to those from classical isothermal experiment at constant humidity. The estimates were more accurate and precise by controlling the extent of drug degradation, changing humidity and temperature range, or by setting the average temperature closer to room temperature. Compared with isothermal experiments at constant humidity, our proposed method saves time, labor, and materials.

  5. African American women's experiences with the initial discovery, diagnosis, and treatment of breast cancer.

    Science.gov (United States)

    Lackey, N R; Gates, M F; Brown, G

    2001-04-01

    To describe the experiences of African American women living with breast cancer following the primary diagnosis and while undergoing initial treatment. Phenomenologic. 13 African American women (ages 30-66) purposefully selected from two oncology clinics in the mid-South. Phenomenologic interviews (transcribed verbatim) and field notes were analyzed using Colaizzi's method of phenomenologic description and analysis. Experience Trajectory, Femininity, and Spirituality were the three major themes. The Experience Trajectory subthemes were finding the lump, getting the diagnosis, undergoing surgery and adjuvant treatment. The Femininity subthemes were loss of all or part of the breast, loss of hair, and sexual attractiveness to a man. Spirituality was reflected as a reliance on God. Telling the story of their experience trajectory during their breast cancer experience is valuable in assessing African American women's feelings, emotions, and fears of body changes that occur during surgery and treatment. Their spirituality helps them through this experience. Research involving both African American women and their partners would provide greater insight into specific relationship patterns and communication related to sexuality during this experience. Nurses need to listen to the stories of African American women about the initial experience of discovery, diagnosis, and treatment of breast cancer so they can be more informed advocates for these women. African American women need more information from healthcare providers regarding the whole experience trajectory.

  6. Granulocytic sarcoma presenting with necrotic cervical lymph nodes as an initial manifestation of childhood leukaemia: imaging features

    Energy Technology Data Exchange (ETDEWEB)

    An, Sang Bu; Cheon, Jung-Eun; Kim, In-One; Kim, Woo Sun [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea); Ahn, Hyo Seop; Shin, Hee Young; Kang, Hyoung Jin; Yeon, Kyung Mo [Seoul National University College of Medicine, Department of Pediatrics, Cancer Research Institute, Seoul (Korea)

    2008-06-15

    We present two cases of granulocytic sarcoma of the cervical lymph nodes with central necrosis as an initial manifestation of childhood leukaemia, focusing on the imaging features. Recognition of the CT and MR imaging findings of granulocytic sarcoma involving the cervical lymph nodes assists the differential diagnosis of noninfective lymphadenopathy in children. (orig.)

  7. Understanding God images and God concepts : Towards a pastoral hermeneutics of the God attachment experience

    NARCIS (Netherlands)

    Counted, Agina Victor

    2015-01-01

    The author looks at the God image experience as an attachment relationship experience with God. Hence, arguing that the God image experience is borne originally out of a parent–child attachment contagion, in such a way that God is often represented in either secure or insecure attachment patterns.

  8. Initial experience in perfusion MR imaging of intracranial major artery occlusion with echo-planar technique

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Mizutani, Yoshiyuki; Inaoka, Sayuki; Hachiya, Junichi

    1997-01-01

    The purpose of this study was to evaluate the usefulness of perfusion MR imaging using a single-shot echo-planar technique in occlusion of intracranial main arteries. Our patient group consisted of 16 patients with internal carotid artery occlusion (n=9), Moyamoya disease (n=4), and middle cerebral artery occlusion (n=3). We performed the echo-planar perfusion studies with a 1.5-T unit using a free-induction-decay-type echo-planar sequence. With a bolus injection of Gd-DTPA, 30 consecutive scans were obtained at 10 sections every 2 seconds. The data were analyzed in three ways: a time-intensity curves in the territory of the involved artery (n=16); semiquantitative flow map of each section representing signal changes due to passage of Gd-DTPA (n=15); and serial images at a selected section (n=7). The time intensity curves were abnormal in 13 patients. The peak of signal drop was delayed in all of them. Flow maps showed focal flow abnormalities in 11 patients, but they were apparently normal in 4 patients probably due to collateral flow. In serial images, delay in appearance and/or disappearance of Gd-DTPA was noted in 6 patients. In patients with occlusion of intracranial main arteries, MR single-shot echo-planar technique is of clinical use because it can provide information about hemodynamic changes in a short examination time, in multiple sections, and with good temporal resolution. (author)

  9. Comparisons of three alternative breast modalities in a common phantom imaging experiment

    International Nuclear Information System (INIS)

    Li Dun; Meaney, Paul M.; Tosteson, Tor D.; Jiang Shudong; Kerner, Todd E.; McBride, Troy O.; Pogue, Brian W.; Hartov, Alexander; Paulsen, Keith D.

    2003-01-01

    Four model-based imaging systems are currently being developed for breast cancer detection at Dartmouth College. A potential advantage of multimodality imaging is the prospect of combining information collected from each system to provide a more complete diagnostic tool that covers the full range of the patient and pathology spectra. In this paper it is shown through common phantom experiments on three of these imaging systems that it was possible to correlate different types of image information to potentially improve the reliability of tumor detection. Imaging experiments were conducted with common phantoms which mimic both dielectric and optical properties of the human breast. Cross modality comparison was investigated through a statistical study based on the repeated data sets of reconstructed parameters for each modality. The system standard error between all methods was generally less than 10% and the correlation coefficient across modalities ranged from 0.68 to 0.91. Future work includes the minimization of bias (artifacts) on the periphery of electrical impedance spectroscopy images to improve cross modality correlation and implementation of the multimodality diagnosis for breast cancer detection

  10. Initial Experience of Using Dual-Energy CT with an Iodine Overlay Image for Hand Psoriatic Arthritis: Comparison Study with Contrast-enhanced MR Imaging.

    Science.gov (United States)

    Fukuda, Takeshi; Umezawa, Yoshinori; Tojo, Shinjiro; Yonenaga, Takenori; Asahina, Akihiko; Nakagawa, Hidemi; Fukuda, Kunihiko

    2017-07-01

    Purpose To determine the feasibility of dual-energy (DE) computed tomography (CT) with an iodine overlay image (IOI) for evaluation of psoriatic arthritis in the hand. Materials and Methods Approval from the institutional ethics committee and written informed consent from all patients were obtained. This prospective study included 16 patients who had psoriasis with finger joint symptoms from January 2015 to January 2016. Contrast material-enhanced (CE) DE CT and 1.5-T CE magnetic resonance (MR) imaging were performed within 1 month of each other. DE CT was performed with a tube voltage of 80 kV and 140 kV with use of a 0.4-mm tin filter. Images acquired with both modalities were evaluated by two radiologists independently by using a semiquantitative scoring system. Interreader agreement was calculated for each modality: Weighted κ values were calculated for synovitis, flexor tenosynovitis, and extensor peritendonitis, and κ values were calculated for periarticular inflammation. With consensus scores and CE MR images as the reference, the sensitivity and specificity of IOI DE CT for inflammatory lesions were calculated. Statistical analysis of discordant readings was performed by using the McNemar test. Results Interreader agreement for inflammatory lesions was excellent or good (weighted κ = 0.83 and κ = 0.75 in IOI DE CT; weighted κ = 0.81 and κ = 0.87 in CE MR imaging). The sensitivity and specificity of IOI DE CT were 0.78 and 0.87, respectively. Total agreement was 86.3%; however, there were significantly more lesions detected with IOI DE CT than with CE MR imaging alone (134 vs 20 lesions in 1120 evaluated items; P the abnormalities detected with IOI DE CT alone were located in distal interphalangeal joints. Conclusion IOI DE CT is a new imaging modality that may be useful for evaluating psoriatic arthritis in the hand, particularly in the detection of inflammatory lesions in small joints, and may be more useful than CE MR imaging, within the limitation

  11. Resting-state functional magnetic resonance imaging for surgical planning in pediatric patients: a preliminary experience.

    Science.gov (United States)

    Roland, Jarod L; Griffin, Natalie; Hacker, Carl D; Vellimana, Ananth K; Akbari, S Hassan; Shimony, Joshua S; Smyth, Matthew D; Leuthardt, Eric C; Limbrick, David D

    2017-12-01

    OBJECTIVE Cerebral mapping for surgical planning and operative guidance is a challenging task in neurosurgery. Pediatric patients are often poor candidates for many modern mapping techniques because of inability to cooperate due to their immature age, cognitive deficits, or other factors. Resting-state functional MRI (rs-fMRI) is uniquely suited to benefit pediatric patients because it is inherently noninvasive and does not require task performance or significant cooperation. Recent advances in the field have made mapping cerebral networks possible on an individual basis for use in clinical decision making. The authors present their initial experience translating rs-fMRI into clinical practice for surgical planning in pediatric patients. METHODS The authors retrospectively reviewed cases in which the rs-fMRI analysis technique was used prior to craniotomy in pediatric patients undergoing surgery in their institution. Resting-state analysis was performed using a previously trained machine-learning algorithm for identification of resting-state networks on an individual basis. Network maps were uploaded to the clinical imaging and surgical navigation systems. Patient demographic and clinical characteristics, including need for sedation during imaging and use of task-based fMRI, were also recorded. RESULTS Twenty patients underwent rs-fMRI prior to craniotomy between December 2013 and June 2016. Their ages ranged from 1.9 to 18.4 years, and 12 were male. Five of the 20 patients also underwent task-based fMRI and one underwent awake craniotomy. Six patients required sedation to tolerate MRI acquisition, including resting-state sequences. Exemplar cases are presented including anatomical and resting-state functional imaging. CONCLUSIONS Resting-state fMRI is a rapidly advancing field of study allowing for whole brain analysis by a noninvasive modality. It is applicable to a wide range of patients and effective even under general anesthesia. The nature of resting

  12. Initial experiences of simultaneous laparoscopic resection of colorectal cancer and liver metastases

    NARCIS (Netherlands)

    Hoekstra, L. T.; Busch, O. R. C.; Bemelman, W. A.; van Gulik, T. M.; Tanis, P. J.

    2012-01-01

    Introduction. Simultaneous resection of primary colorectal carcinoma (CRC) and synchronous liver metastases (SLMs) is subject of debate with respect to morbidity in comparison to staged resection. The aim of this study was to evaluate our initial experience with this approach. Methods. Five patients

  13. PET/MRI in head and neck cancer: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Platzek, Ivan; Laniado, Michael [Dresden University Hospital, Department of Radiology, Dresden (Germany); Beuthien-Baumann, Bettina [Dresden University Hospital, Department of Nuclear Medicine, Dresden (Germany); Schneider, Matthias [Dresden University Hospital, Oral and Maxillofacial Surgery, Dresden (Germany); Gudziol, Volker [Dresden University Hospital, Department of Otolaryngology, Dresden (Germany); Langner, Jens; Schramm, Georg; Hoff, Joerg van den [Institute of Bioinorganic and Radiopharmaceutical Chemistry, Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Kotzerke, Joerg [Dresden University Hospital, Nuclear Medicine, Dresden (Germany)

    2013-01-15

    To evaluate the feasibility of PET/MRI (positron emission tomography/magnetic resonance imaging) with FDG ({sup 18}F-fluorodeoxyglucose) for initial staging of head and neck cancer. The study group comprised 20 patients (16 men, 4 women) aged between 52 and 81 years (median 64 years) with histologically proven squamous cell carcinoma of the head and neck region. The patients underwent a PET scan on a conventional scanner and a subsequent PET/MRI examination on a whole-body hybrid system. FDG was administered intravenously prior to the conventional PET scan (267-395 MBq FDG, 348 MBq on average). The maximum standardized uptake values (SUV{sub max}) of the tumour and of both cerebellar hemispheres were determined for both PET datasets. The numbers of lymph nodes with increased FDG uptake were compared between the two PET datasets. No MRI-induced artefacts where observed in the PET images. The tumour was detected by PET/MRI in 17 of the 20 patients, by PET in 16 and by MRI in 14. The PET/MRI examination yielded significantly higher SUV{sub max} than the conventional PET scanner for both the tumour (p < 0.0001) and the cerebellum (p = 0.0009). The number of lymph nodes with increased FDG uptake detected using the PET dataset from the PET/MRI system was significantly higher the number detected by the stand-alone PET system (64 vs. 39, p = 0.001). The current study demonstrated that PET/MRI of the whole head and neck region is feasible with a whole-body PET/MRI system without impairment of PET or MR image quality. (orig.)

  14. Analysis of the initial experience with first PET scanner and in Chile

    International Nuclear Information System (INIS)

    Massardo, Teresa; Jofre, Maria Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Valdebenito, Robert; Galaz, Rodrigo

    2005-01-01

    The main application of positron emission tomography (PET) with Fluorine 18- deoxyglucose (FDG) is in the management of cancer patients due to the high correlation between cellular glucidic activity and malignancy. Objective: To analyze the initial group of cases performed with the first dedicated PET scanner in Chile. Method: We present the first 500 patients studied with a Siemens HR+ system using FDG produced at the Chilean Atomic Energy Commission facilities. Results: Most of the referrals were from oncology (96%). Four percent were studied due to neurological or psychiatric disorders and only 1% for myocardial viability. Lung lesions, gastrointestinal and breast carcinomas, melanoma and lymphoma corresponded to the most frequent diagnosis. Lung and lymphoma patients had clinical follow-up. There was good concordance with anatomical images and histology in those cases with available data. Fusion of FDG images with computed tomography or magnetic resonance was helpful. In a significant number of patients new tumoral sites were detected Conclusion: We confirm that in clinical practice, metabolic imaging with F18-FDG is helpful for cancer evaluation and management (au)

  15. Analysis of the initial experience with first PET scanner and in Chile

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa; Jofre, Maria Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Valdebenito, Robert; Galaz, Rodrigo [Centro PET de Imagenes Moleculares, Hospital Militar da Santiago, Santiago (Chile)

    2005-07-01

    The main application of positron emission tomography (PET) with Fluorine 18- deoxyglucose (FDG) is in the management of cancer patients due to the high correlation between cellular glucidic activity and malignancy. Objective: To analyze the initial group of cases performed with the first dedicated PET scanner in Chile. Method: We present the first 500 patients studied with a Siemens HR+ system using FDG produced at the Chilean Atomic Energy Commission facilities. Results: Most of the referrals were from oncology (96%). Four percent were studied due to neurological or psychiatric disorders and only 1% for myocardial viability. Lung lesions, gastrointestinal and breast carcinomas, melanoma and lymphoma corresponded to the most frequent diagnosis. Lung and lymphoma patients had clinical follow-up. There was good concordance with anatomical images and histology in those cases with available data. Fusion of FDG images with computed tomography or magnetic resonance was helpful. In a significant number of patients new tumoral sites were detected Conclusion: We confirm that in clinical practice, metabolic imaging with F18-FDG is helpful for cancer evaluation and management (au)

  16. Image processing analysis of traditional Gestalt vision experiments

    Science.gov (United States)

    McCann, John J.

    2002-06-01

    In the late 19th century, the Gestalt Psychology rebelled against the popular new science of Psychophysics. The Gestalt revolution used many fascinating visual examples to illustrate that the whole is greater than the sum of all the parts. Color constancy was an important example. The physical interpretation of sensations and their quantification by JNDs and Weber fractions were met with innumerable examples in which two 'identical' physical stimuli did not look the same. The fact that large changes in the color of the illumination failed to change color appearance in real scenes demanded something more than quantifying the psychophysical response of a single pixel. The debates continues today with proponents of both physical, pixel-based colorimetry and perceptual, image- based cognitive interpretations. Modern instrumentation has made colorimetric pixel measurement universal. As well, new examples of unconscious inference continue to be reported in the literature. Image processing provides a new way of analyzing familiar Gestalt displays. Since the pioneering experiments by Fergus Campbell and Land, we know that human vision has independent spatial channels and independent color channels. Color matching data from color constancy experiments agrees with spatial comparison analysis. In this analysis, simple spatial processes can explain the different appearances of 'identical' stimuli by analyzing the multiresolution spatial properties of their surrounds. Benary's Cross, White's Effect, the Checkerboard Illusion and the Dungeon Illusion can all be understood by the analysis of their low-spatial-frequency components. Just as with color constancy, these Gestalt images are most simply described by the analysis of spatial components. Simple spatial mechanisms account for the appearance of 'identical' stimuli in complex scenes. It does not require complex, cognitive processes to calculate appearances in familiar Gestalt experiments.

  17. Results from neutron imaging of ICF experiments at NIF

    Science.gov (United States)

    Merrill, F. E.; Danly, C. R.; Fittinghoff, D. N.; Grim, G. P.; Guler, N.; Volegov, P. L.; Wilde, C. H.

    2016-03-01

    In 2011 a neutron imaging diagnostic was commissioned at the National Ignition Facility (NIF). This new system has been used to collect neutron images to measure the size and shape of the burning DT plasma and the surrounding fuel assembly. The imaging technique uses a pinhole neutron aperture placed between the neutron source and a neutron detector. The detection system measures the two-dimensional distribution of neutrons passing through the pinhole. This diagnostic collects two images at two times. The long flight path for this diagnostic, 28 m, results in a chromatic separation of the neutrons, allowing the independently timed images to measure the source distribution for two neutron energies. Typically one image measures the distribution of the 14 MeV neutrons, and the other image measures the distribution of the 6-12 MeV neutrons. The combination of these two images has provided data on the size and shape of the burning plasma within the compressed capsule, as well as a measure of the quantity and spatial distribution of the cold fuel surrounding this core. Images have been collected for the majority of the experiments performed as part of the ignition campaign. Results from this data have been used to estimate a burn-averaged fuel assembly as well as providing performance metrics to gauge progress towards ignition. This data set and our interpretation are presented.

  18. Image quality of the cat eye measured during retinal ganglion cell experiments.

    Science.gov (United States)

    Bonds, A B; Enroth-Cugell, C; Pinto, L H

    1972-01-01

    1. The modulation transfer function (MTF) of the dioptrics of fifteen cat eyes was determined. The aerial image, formed by the eye of a standard object (a 0.5-1.0 degrees annulus), was photographed. The transmission of the film negative was measured with a scanning microdensitometer to yield the light distribution within the aerial image. Correcting for the double passage, this experimentally determined light distribution and the known object light distribution were used to obtain the MTF, applying Fourier methods. Each MTF was used to calculate the light distribution within the retinal image of stimuli of various geometry used in experiments on retinal ganglion cells in the same eye.2. When the eye was equipped with an artificial pupil of the same size as that used in the neurophysiological experiments (4.0-4.8 mm diam.) the MTF had fallen to 0.5 at 2.43 c/deg. When the pupil was removed the MTF had fallen to 0.5 at a much lower spatial frequency (1.0 c/deg). This shows that even when one uses an artificial pupil too large to provide optimal image quality there is a vast improvement over using no pupil.3. These image quality measurements were prompted by the need to know the actual stimulus image in experiments on the functional organization of the receptive field, a need exemplified in this paper by a few specific physiological results. The full neurophysiological results appear in the next two papers.

  19. Large-Scale Laboratory Experiments of Initiation of Motion and Burial of Objects under Currents and Waves

    Science.gov (United States)

    Landry, B. J.; Wu, H.; Wenzel, S. P.; Gates, S. J.; Fytanidis, D. K.; Garcia, M. H.

    2017-12-01

    Unexploded ordnances (UXOs) can be found at the bottom of coastal areas as the residue of military wartime activities, training or accidents. These underwater objects are hazards for humans and the coastal environment increasing the need for addressing the knowledge gaps regarding the initiation of motion, fate and transport of UXOs under currents and wave conditions. Extensive experimental analysis was conducted for the initiation of motion of UXOs under various rigid bed roughness conditions (smooth PVC, pitted steel, marbles, gravels and bed of spherical particles) for both unidirectional and oscillatory flows. Particle image velocimetry measurements were conducted under both flow conditions to resolve the flow structure estimate the critical flow conditions for initiation of motion of UXOs. Analysis of the experimental observations shows that the geometrical characteristics of the UXOs, their properties (i.e. volume, mass) and their orientation with respect to the mean flow play an important role on the reorientation and mobility of the examined objects. A novel unified initiation of motion diagram is proposed using an effective/unified hydrodynamic roughness and a new length scale which includes the effect of the projected area and the bed-UXO contact area. Both unidirectional and oscillatory critical flow conditions collapsed into a single dimensionless diagram highlighting the importance and practical applicability of the proposed work. In addition to the rigid bed experiments, the burial dynamics of proud UXOs on a mobile sand bed were also examined. The complex flow-bedform-UXOs interactions were evaluated which highlighted the effect of munition density on burial rate and final burial depth. Burial dynamics and mechanisms for motion were examined for various UXOs types, and results show that, for the case of the low density UXOs under energetic conditions, lateral transport coexists with burial. Prior to burial, UXO re-orientation was also observed

  20. Imaging correlated three-particle continuum states. Experiment and theory on the non-adiabatic projection of bound triatomic hydrogen into three separated atoms

    International Nuclear Information System (INIS)

    Fechner, Peer Cornelis

    2015-01-01

    The central topic of this thesis is the experimental observation and the theoretical modeling of non-adiabatic three-body dissociation of H_3 and D_3 neutral triatomic hydrogen molecules. Our goal is to lend a meaning to the observed momentum vector correlation (MVC) of the three emerging ground state hydrogen atoms, for example H_3→H(1s)+H(1s)+H(1s), in terms of symmetries of the nuclear molecular wave function and of the non-adiabatic coupling which initiates this decay. In many experiments carried out over the years, a wealth of state specific MVCs was collected by different research groups. The MVCs are imaged in form of so-called Dalitz plots which show a rich structure of maxima and nodal lines, depending on the initial state of the triatomic hydrogen neutral. Theory was slow to catch up with experiment and only by this year, 2015, a general agreement was accomplished. Nevertheless, these models lack of an easy understanding of the underlying physics as many numerical calculations are involved. The theoretical model presented in this thesis follows a different approach which is more guided by the imaging character of our experiments. We concentrate on a rather qualitative treatment by limiting ourselves to the essential ingredients only. This proceeding contributes to giving a physical interpretation of the structures in the Dalitz plots in the following form: Three-particle coincident imaging offers a direct view of the emerging spatial continuum wave function of a predissociating triatomic molecule as it evolves from molecular spatial dimensions into the realm of independent free particles. This latter result is discussed in the context of the so-called Imaging Theorem, the second main part of this work. A third major part of this thesis pertains to obtaining molecular momentum wave functions in separated degrees-of-freedom via Fourier transformation. Even for triatomic hydrogen - the most simple polyatomic molecule - this is a challenging task. The

  1. Liposomes - experiment of magnetic resonance imaging application

    International Nuclear Information System (INIS)

    Mathieu, S.

    1987-01-01

    Most pharmaceutical research effort with liposomes has been involved with the investigation of their use as drug carriers to particular target organs. Recently there has been a growing interest in liposomes not only as carrier of drugs but as a tool for the introduction of various substances into the human body. In this study, liposome delivery of nitroxyl radicals as NMR contrast agent for improved tissue imaging is experimented in rats [fr

  2. 99Tcm-Neurolite brain SPECT imaging as an outcome predictor after brain trauma: initial experience

    International Nuclear Information System (INIS)

    Howarth, D.M.; Lan, L.; Booth, G.; Christie, J.; Bookalil, A.; Pollack, M.; Pacey, D.

    1999-01-01

    Full text: The aim of this study was to use semi-quantitative 99 Tc m -ethylene cysteine dimer (Neurolite) cerebral blood flow (CBF) SPET brain imaging to assess its role in predicting outcome after brain trauma. Twelve adult patients (9 males, 3 females) who sustained moderate to severe brain trauma were studied by CBF/SPET within 4 weeks of the injury (scan A) and again after 1 year (scan B). Clinical assessment was also performed at these times and included extensive neuropsychometric testing. Patients received 800-850 MBq 99 Tc m -Neurolite intravenously, and were imaged using a triple-headed gamma camera with LEUHR fan beam collimators. Processing, filtering, reconstruction and data set selection were identical for scans A and B. Semi-quantitative analysis was performed using 25 regions of interest in the cerebral cortex and deep structures in 2 coronal, 2 sagittal and 3 oblique planes. Normalized mean counts per pixel for the whole brain, and regional brain ratios were calculated. Scans A and B were compared and correlated to the clinical outcome data. Two patients with minimal CBF abnormalities made full recoveries. The remaining 10 had moderate to severe focal CBF defects, which showed no significant improvement at 12 months. Of these patients, 2 had moderate disability, 3 had severe to moderate disability and 2 had severe disability at 12 months. Patients with persisting focal abnormal CBF showed persisting neurological deficits. Neurolite brain CBF imaging is a useful method of predicting outcome after moderate to severe head injury

  3. Barrier experiment: Shock initiation under complex loading

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-01-12

    The barrier experiments are a variant of the gap test; a detonation wave in a donor HE impacts a barrier and drives a shock wave into an acceptor HE. The question we ask is: What is the trade-off between the barrier material and threshold barrier thickness to prevent the acceptor from detonating. This can be viewed from the perspective of shock initiation of the acceptor subject to a complex pressure drive condition. Here we consider key factors which affect whether or not the acceptor undergoes a shock-to-detonation transition. These include the following: shock impedance matches for the donor detonation wave into the barrier and then the barrier shock into the acceptor, the pressure gradient behind the donor detonation wave, and the curvature of detonation front in the donor. Numerical simulations are used to illustrate how these factors affect the reaction in the acceptor.

  4. Gadopentetate-dimeglumine-enhanced MR imaging of osteonecrosis and osteochondritis dissecans of the elbow: initial experience

    International Nuclear Information System (INIS)

    Peiss, J.; Adam, G.; Casser, R.; Urhahn, R.; Guenther, R.W.

    1995-01-01

    Magnetic resonance imaging (MRI) was performed on seven patients with aseptic osteonecrosis (n=4) and osteochondritis dissecans (OCD; n=3) of the elbow. Precontrast MRI was superior to plain radiographs, which did not show any abnormality in three cases of osteonecrosis. On gadopentetate-dimeglumine-enhanced T1-weighted images, which were obtained in three patients with osteonecrosis and three patients with OCD, all cases of osteonecrosis demonstrated homogeneous enhancement of the lesions. All cases of OCD were diagnosed on plain radiographs. On MRI one showed significant enhancement of the loose body. In another case an incompletely enhancing loose body was surrounded by a diffusely enhancing region. In the third patient only a small marginal enhancement of the defect was observed. Our results suggest that MRI can improve the accuracy in diagnosis of aseptic osteonecrosis of the elbow. The use of gadopentetate dimeglumine allows the viability of the lesions or the loose bodies to be demonstrated and reparative tissue to be detected. (orig.)

  5. Energetic neutral atom imaging with the Polar CEPPAD/IPS instrument: Initial forward modeling results

    International Nuclear Information System (INIS)

    Henderson, M.G.; Reeves, G.D.; Moore, K.R.; Spence, H.E.; Jorgensen, A.M.; Roelof, E.C.

    1997-01-01

    Although the primary function of the CEP-PAD/IPS instrument on Polar is the measurement of energetic ions in-situ, it has also proven to be a very capable Energetic neutral Atom (ENA) imager. Raw ENA images are currently being constructed on a routine basis with a temporal resolution of minutes during both active and quiet times. However, while analyses of these images by themselves provide much information on the spatial distribution and dynamics of the energetic ion population in the ring current, detailed modeling is required to extract the actual ion distributions. In this paper, the authors present the initial results of forward modeling an IPS ENA image obtained during a small geo-magnetic storm on June 9, 1997. The equatorial ion distribution inferred with this technique reproduces the expected large noon/midnight and dawn/dusk asymmetries. The limitations of the model are discussed and a number of modifications to the basic forward modeling technique are proposed which should significantly improve its performance in future studies

  6. Experimental test accelerator: description and results of initial experiments

    International Nuclear Information System (INIS)

    Fessenden, T.; Birx, D.; Briggs, R.

    1980-01-01

    The ETA is a high current (10,000 Amp) linear induction accelerator that produces short (30 ns) pulses of electrons at 5 MeV twice per second or in bursts of 5 pulses separated by as little as one millisecond. At this time the machine has operated at 65% of its design current and 90% of the design voltage. This report contains a description of the accelerator and its diagnostics; the results of the initial year of operation; a comparison of design codes with experiments on beam transport; and a discussion of some of the special problems and their status

  7. Discharge initiation experiments in the Tokapole II tokamak

    International Nuclear Information System (INIS)

    Shepard, D.A.

    1984-01-01

    Experiments in the Tokapole II tokamak demonstrate the benefits of high density (n/sub e//n/sub o/ greater than or equal to 0.01) preionization by reducing four quantities at startup: necessary toroidal loop voltage (V 1 ) (50%), volt-second consumption (40-50%), impurity radiation (25-50%), and runaway electron production (approx. 80-100%). A zero-dimensional code models the loop voltage reduction dependence on preionization density and predicts a similar result for reactor scale devices. The code shows low initial resistivity and a high resistivity time derivative contribute to loop voltage reduction. Microwaves at the electron cyclotron resonance (ECR) frequency and plasma gun injection produce high density preionization, which reduces the initial V 1 , volt-second consumption, and runaways. The ECR preionization also reduces impurity radiation by shortening the time from voltage application to current channel formation. This, evidently, reduces the total plasma-wall interaction at startup. The power balance of the ECR plasma in a toroidal-field-only case was studied using Langmuir probes and impurity doping. The vertical electric field and current, which result from curvature drift, were measured as approx. 10 V/cm and 50 amps, respectively, and exceeded expected values for the bulk electron temperature (approx. 10 eV)

  8. Krypton ventilation imaging using dual-energy CT in chronic obstructive pulmonary disease patients: initial experience.

    Science.gov (United States)

    Hachulla, Anne-Lise; Pontana, François; Wemeau-Stervinou, Lidwine; Khung, Suonita; Faivre, Jean-Baptiste; Wallaert, Benoit; Cazaubon, Jean-François; Duhamel, Alain; Perez, Thierry; Devos, Patrick; Remy, Jacques; Remy-Jardin, Martine

    2012-04-01

    To evaluate the tolerance and level of enhancement achievable after inhalation of stable krypton. This study was approved by the institutional review board and the local ethics committee. Written informed consent was obtained from all subjects. The study was planned as a Fleming two-stage design, enabling one to assess the effectiveness of a newer treatment or technique on a small number of patients. At the end of each stage, the results are computed, and the trial can be stopped if the effectiveness is less than a minimum success rate or greater than an expected success rate. After informed consent was obtained, a total of 32 patients (ie, two successive series of 16 patients each) with severe emphysema underwent a dual-source, dual-energy chest computed tomographic (CT) examination after inhalation of a mixture of stable krypton (80%) and oxygen (20%), with reconstruction of diagnostic and ventilation images. For each patient, two regions of interest were selected on a diagnostic image, one in a region of severe emphysema (presumed to be poorly ventilated or not ventilated) and a second one in a region devoid of structural abnormalities (presumed to be normally ventilated), with measurements of attenuation values on the corresponding ventilation image. All examinations were successfully performed, without adverse effects. Differences in attenuation between normal lung and emphysematous areas were found in 28 patients (88%; 95% confidence interval: 71%, 96.5%). The maximal level of attenuation within normal lung was 18.5 HU. Krypton attenuation difference between normal and emphysematous lung was significant, with a median value of 51.8% (P krypton and its excellent clinical tolerance makes this gas eligible for ventilation CT examinations. © RSNA, 2012.

  9. Soil transference patterns on bras: Image processing and laboratory dragging experiments.

    Science.gov (United States)

    Murray, Kathleen R; Fitzpatrick, Robert W; Bottrill, Ralph S; Berry, Ron; Kobus, Hilton

    2016-01-01

    In a recent Australian homicide, trace soil on the victim's clothing suggested she was initially attacked in her front yard and not the park where her body was buried. However the important issue that emerged during the trial was how soil was transferred to her clothing. This became the catalyst for designing a range of soil transference experiments (STEs) to study, recognise and classify soil patterns transferred onto fabric when a body is dragged across a soil surface. Soil deposits of interest in this murder were on the victim's bra and this paper reports the results of anthropogenic soil transfer to bra-cups and straps caused by dragging. Transfer patterns were recorded by digital photography and photomicroscopy. Eight soil transfer patterns on fabric, specific to dragging as the transfer method, appeared consistently throughout the STEs. The distinctive soil patterns were largely dependent on a wide range of soil features that were measured and identified for each soil tested using X-ray Diffraction and Non-Dispersive Infra-Red analysis. Digital photographs of soil transfer patterns on fabric were analysed using image processing software to provide a soil object-oriented classification of all soil objects with a diameter of 2 pixels and above transferred. Although soil transfer patterns were easily identifiable by naked-eye alone, image processing software provided objective numerical data to support this traditional (but subjective) interpretation. Image software soil colour analysis assigned a range of Munsell colours to identify and compare trace soil on fabric to other trace soil evidence from the same location; without requiring a spectrophotometer. Trace soil from the same location was identified by linking soils with similar dominant and sub-dominant Munsell colour peaks. Image processing numerical data on the quantity of soil transferred to fabric, enabled a relationship to be discovered between soil type, clay mineralogy (smectite), particle size and

  10. Initial resident refractive surgical experience: outcomes of PRK and LASIK for myopia.

    Science.gov (United States)

    Wagoner, Michael D; Wickard, Joseph C; Wandling, George R; Milder, Lisa C; Rauen, Matthew P; Kitzmann, Anna S; Sutphin, John E; Goins, Kenneth M

    2011-03-01

    To evaluate and compare the outcome of initial resident surgical experience with photorefractive keratectomy (PRK) and LASIK. Retrospective review of all cases performed with the VISX Star S4 platform (Abbott Medical Optics) between July 1, 2003 and June 30, 2007. Inclusion criteria were spherical equivalent of -0.50 to -10.00 diopters (D), refractive astigmatic error of ≤3.00 D, intention to provide full distance correction, and minimum 3-month postoperative follow-up after initial ablation or retreatment (if performed). A total of 153 cases performed by 20 different residents met the inclusion criteria; 38 eyes underwent PRK and 115 eyes had LASIK. After initial treatment, mean Snellen uncorrected distance visual acuity (UDVA) after PRK was 20/17.3 and after LASIK was 20/19.5. Photorefractive keratectomy was associated with a significantly better approximation between preoperative corrected distance visual acuity (CDVA) and postoperative UDVA (ΔlogMAR 0.009 vs 0.091; P=.004) and a greater percentage of eyes that achieved UDVA of 20/20 or better (94.7% vs 78.3%; P=.02) or 20/30 or better (100% vs 87.8%; P=.02). There was a higher prevalence of retreatment in eyes that underwent LASIK (7.0% vs 0%; P=.20). One (0.9%) eye lost 2 lines of CDVA after LASIK. Supervised refractive surgery residents can achieve excellent visual outcomes in patients operated during their initial refractive experience. Photorefractive keratectomy was associated with better visual outcome than LASIK. Copyright 2011, SLACK Incorporated.

  11. Hyperspectral Imaging of Forest Resources: The Malaysian Experience

    Science.gov (United States)

    Mohd Hasmadi, I.; Kamaruzaman, J.

    2008-08-01

    Remote sensing using satellite and aircraft images are well established technology. Remote sensing application of hyperspectral imaging, however, is relatively new to Malaysian forestry. Through a wide range of wavelengths hyperspectral data are precisely capable to capture narrow bands of spectra. Airborne sensors typically offer greatly enhanced spatial and spectral resolution over their satellite counterparts, and able to control experimental design closely during image acquisition. The first study using hyperspectral imaging for forest inventory in Malaysia were conducted by Professor Hj. Kamaruzaman from the Faculty of Forestry, Universiti Putra Malaysia in 2002 using the AISA sensor manufactured by Specim Ltd, Finland. The main objective has been to develop methods that are directly suited for practical tropical forestry application at the high level of accuracy. Forest inventory and tree classification including development of single spectral signatures have been the most important interest at the current practices. Experiences from the studies showed that retrieval of timber volume and tree discrimination using this system is well and some or rather is better than other remote sensing methods. This article reviews the research and application of airborne hyperspectral remote sensing for forest survey and assessment in Malaysia.

  12. Initial experience with SPECT imaging of the brain using I-123 p-iodoamphetamine in focal epilepsy

    International Nuclear Information System (INIS)

    La Manna, M.M.; Sussman, N.M.; Harner, R.N.; Kaplan, L.R.; Hershey, B.L.; Bernstein, D.R.; Parker, J.A.; Wolodzko, J.G.; Popky, G.L.

    1986-01-01

    Twenty-three patients with complex partial seizures refractory to medical treatment were examined with routine electroencephalography (EEG), closed-circuit television EEG (CCTV-EEG), CT and MR imaging, neuropsychological tests, and interictal single photon emission CT with I-123 rho-iodoamphetamine (IMP SPECT). In three patients CT and MR imaging results correlated with the epileptogenic foci as identified on CCTV-EEG. In 21 patients SPECT identified areas of focal reduction in tracer uptake that correlated with the epileptogenic focus identified on CCTV-EEG. In addition, SPECT disclosed other areas of neurologic dysfunction as elicited on neuropsychological tests. Thus, IMP SPECT is a useful tool for localizing epileptogenic foci and their associated dynamic deficits

  13. An MRI system for imaging neonates in the NICU: initial feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Tkach, Jean A.; Loew, Wolfgang; Pratt, Ron G.; Daniels, Barret R.; Giaquinto, Randy O.; Winter, Patrick M.; Li, Yu; Dumoulin, Charles L. [Cincinnati Children' s Hospital Medical Center, Imaging Research Center, Department of Radiology, Cincinnati, OH (United States); Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Hillman, Noah H.; Jobe, Alan H.; Kallapur, Suhas G.; Merhar, Stephanie L.; Ikegami, Machiko; Whitsett, Jeffrey A. [Perinatal Institute, Cincinnati Children' s Hospital Medical Center, Division of Neonatology and Pulmonary Biology, Cincinnati, OH (United States); Kline-Fath, Beth M. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2012-11-15

    Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate. (orig.)

  14. An MRI system for imaging neonates in the NICU: initial feasibility study

    International Nuclear Information System (INIS)

    Tkach, Jean A.; Loew, Wolfgang; Pratt, Ron G.; Daniels, Barret R.; Giaquinto, Randy O.; Winter, Patrick M.; Li, Yu; Dumoulin, Charles L.; Hillman, Noah H.; Jobe, Alan H.; Kallapur, Suhas G.; Merhar, Stephanie L.; Ikegami, Machiko; Whitsett, Jeffrey A.; Kline-Fath, Beth M.

    2012-01-01

    Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate. (orig.)

  15. An MRI system for imaging neonates in the NICU: initial feasibility study.

    Science.gov (United States)

    Tkach, Jean A; Hillman, Noah H; Jobe, Alan H; Loew, Wolfgang; Pratt, Ron G; Daniels, Barret R; Kallapur, Suhas G; Kline-Fath, Beth M; Merhar, Stephanie L; Giaquinto, Randy O; Winter, Patrick M; Li, Yu; Ikegami, Machiko; Whitsett, Jeffrey A; Dumoulin, Charles L

    2012-11-01

    Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate.

  16. Effect of Reading Ability and Internet Experience on Keyword-Based Image Search

    Science.gov (United States)

    Lei, Pei-Lan; Lin, Sunny S. J.; Sun, Chuen-Tsai

    2013-01-01

    Image searches are now crucial for obtaining information, constructing knowledge, and building successful educational outcomes. We investigated how reading ability and Internet experience influence keyword-based image search behaviors and performance. We categorized 58 junior-high-school students into four groups of high/low reading ability and…

  17. Experience with magnetic resonance imaging of human subjects with passive implants and tattoos at 7 T: a retrospective study.

    Science.gov (United States)

    Noureddine, Yacine; Bitz, Andreas K; Ladd, Mark E; Thürling, Markus; Ladd, Susanne C; Schaefers, Gregor; Kraff, Oliver

    2015-12-01

    Over the last decade, the number of clinical MRI studies at 7 T has increased dramatically. Since only limited information about the safety of implants/tattoos is available at 7 T, many centers either conservatively exclude all subjects with implants/tattoos or have started to perform dedicated tests for selected implants. This work presents our experience in imaging volunteers with implants/tattoos at 7 T over the last seven and a half years. 1796 questionnaires were analyzed retrospectively to identify subjects with implants/tattoos imaged at 7 T. For a total of 230 subjects, the type of local transmit/receive RF coil used for examination, imaging sequences, acquisition time, and the type of implants/tattoos and their location with respect to the field of view were documented. These subjects had undergone examination after careful consideration by an internal safety panel consisting of three experts in MR safety and physics. None of the subjects reported sensations of heat or force before, during, or after the examination. None expressed any discomfort related to implants/tattoos. Artifacts were reported in 52% of subjects with dental implants; all artifacts were restricted to the mouth area and did not affect image quality in the brain parenchyma. Our initial experience at 7 T indicates that a strict rejection of subjects with tattoos and/or implants is not justified. Imaging can be conditionally performed in carefully selected subjects after collection of substantial safety information and evaluation of the detailed exposure scenario (RF coil/type and position of implant). Among the assessed subjects with tattoos, no side effects from the exposure to 7 T MRI were reported.

  18. Two-dimensional sonographic cine imaging improves confidence in the initial evaluation of the fetal heart.

    Science.gov (United States)

    Poole, Patricia Sims; Chung, Romy; Lacoursiere, Yvette; Palmieri, Carolina Rossi; Hull, Andrew; Engelkemier, Dawn; Rochelle, Michele; Trivedi, Neha; Pretorius, Dolores H

    2013-06-01

    Initial screening sonography of the fetal heart with static images is often inadequate, resulting in repeated imaging or failure to detect abnormalities. We hypothesized that the addition of short cine clips would reduce the need for repeated imaging. Two-dimensional (2D) static sonograms and short 2D cine clips of the 4-chamber view and left and right ventricular outflow tracts were obtained from 342 patients with gestational ages of greater than 16 weeks. A diagnostic radiologist and a perinatologist retrospectively reviewed the static and cine images independently and graded them as normal, abnormal, or suboptimal. A statistically significant increase in the number of structures called normal was seen when 2D cine clips were added to static imaging for both observers (P cine images versus 61.9% with static images alone, whereas the perinatologist recorded 68.1% as normal versus 58.8%, respectively. The radiologist called 77.8% of structures normal with cine images only versus 61.9% with static images only (P cine images alone (38.9%) versus static images alone (58.8%). The use of cine loops alone resulted in no significant increase in the ability to clear the heart as normal. The maternal body mass index was inversely associated with the ability to clear structures when 2D cine images were added to static images (P cine clips to standard 2D static imaging of the fetal heart significantly improves the number of structures cleared as normal. Two-dimensional cine clips are easily obtained, add little time to a study, and require minimal archival space.

  19. Professionals' experiences of imaging in the radiography process – A phenomenological approach

    International Nuclear Information System (INIS)

    Lundvall, Lise-Lott; Dahlgren, Madeleine Abrandt; Wirell, Staffan

    2014-01-01

    Introduction: Previous studies on radiographers' professional work have shown that this practice covers both technology and patient care. How these two competence areas blend together in practice needs to be investigated. The professionals' experiences of their work have not been studied in depth, and there is a need to focus on their experiences of the main features of their practice. The aim: To explore, from the perspective of the radiographer, the general tasks and responsibilities of their work. Method: Data were generated through a combination of open interviews with radiographers and observations of their work with Computer Tomography (CT) and Magnetic Resonance Imaging (MRI). The interviews and observations were analysed using an interpretative phenomenological method. Result: Radiographers' professional work with diagnostic imaging, in a Swedish context, can be viewed as a problem-solving process involving judgments and responsibility for obtaining images that can be used for diagnosis. The examination process comprises three phases; planning, producing the images, and evaluation. In the first phase the radiographer makes judgments on adapting the method to the individual patient, and the second phase involves responsibilities and practical skills for image production. In the third phase, the quality of the images is judged in relation to the actual patient and the imaging process itself. Conclusions: Radiographers consider that the main features of their professional work are patient safety aspects and their knowledge and skills regarding how to produce images of optimal quality, in the actual circumstances of each examination

  20. Energy efficiency initiatives: Indian experience

    Energy Technology Data Exchange (ETDEWEB)

    Dey, Dipankar [ICFAI Business School, Kolkata, (IBS-K) (India)

    2007-07-01

    India, with a population of over 1.10 billion is one of the fastest growing economies of the world. As domestic sources of different conventional commercial energy are drying up, dependence on foreign energy sources is increasing. There exists a huge potential for saving energy in India. After the first 'oil shock' (1973), the government of India realized the need for conservation of energy and a 'Petroleum Conservation Action Group' was formed in 1976. Since then many initiatives aiming at energy conservation and improving energy efficiency, have been undertaken (the establishment of Petroleum Conservation Research Association in 1978; the notification of Eco labelling scheme in 1991; the formation of Bureau of Energy Efficiency in 2002). But no such initiative was successful. In this paper an attempt has been made to analyze the changing importance of energy conservation/efficiency measures which have been initiated in India between 1970 and 2005.The present study tries to analyze the limitations and the reasons of failure of those initiatives. The probable reasons are: fuel pricing mechanism (including subsidies), political factors, corruption and unethical practices, influence of oil and related industry lobbies - both internal and external, the economic situation and the prolonged protection of domestic industries. Further, as India is opening its economy, the study explores the opportunities that the globally competitive market would offer to improve the overall energy efficiency of the economy. The study suggests that the Bureau of Energy Efficiency (BEE) - the newly formed nodal agency for improving energy efficiency of the economy may be made an autonomous institution where intervention from the politicians would be very low. For proper implementation of different initiatives to improve energy efficiency, BEE should involve more the civil societies (NGO) from the inception to the implementation stage of the programs. The paper also

  1. Quantitative shear wave ultrasound elastography: initial experience in solid breast masses.

    Science.gov (United States)

    Evans, Andrew; Whelehan, Patsy; Thomson, Kim; McLean, Denis; Brauer, Katrin; Purdie, Colin; Jordan, Lee; Baker, Lee; Thompson, Alastair

    2010-01-01

    Shear wave elastography is a new method of obtaining quantitative tissue elasticity data during breast ultrasound examinations. The aims of this study were (1) to determine the reproducibility of shear wave elastography (2) to correlate the elasticity values of a series of solid breast masses with histological findings and (3) to compare shear wave elastography with greyscale ultrasound for benign/malignant classification. Using the Aixplorer® ultrasound system (SuperSonic Imagine, Aix en Provence, France), 53 solid breast lesions were identified in 52 consecutive patients. Two orthogonal elastography images were obtained of each lesion. Observers noted the mean elasticity values in regions of interest (ROI) placed over the stiffest areas on the two elastography images and a mean value was calculated for each lesion. A sub-set of 15 patients had two elastography images obtained by an additional operator. Reproducibility of observations was assessed between (1) two observers analysing the same pair of images and (2) findings from two pairs of images of the same lesion taken by two different operators. All lesions were subjected to percutaneous biopsy. Elastography measurements were correlated with histology results. After preliminary experience with 10 patients a mean elasticity cut off value of 50 kilopascals (kPa) was selected for benign/malignant differentiation. Greyscale images were classified according to the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS). BI-RADS categories 1-3 were taken as benign while BI-RADS categories 4 and 5 were classified as malignant. Twenty-three benign lesions and 30 cancers were diagnosed on histology. Measurement of mean elasticity yielded an intraclass correlation coefficient of 0.99 for two observers assessing the same pairs of elastography images. Analysis of images taken by two independent operators gave an intraclass correlation coefficient of 0.80. Shear wave elastography versus

  2. Neuro-Behcet's disease: initial and follow-up MR imaging findings

    International Nuclear Information System (INIS)

    Kim, Chan Sung; Choi, Sun Seob; Lee, Ha Jong; Ha, Dong Ho; Lee, Yong Il

    1998-01-01

    The purpose of this study was to evaluate initial and follow-up MR imaging(MRI) findings of neuro-Behcet's disease. MRI of seven clinically diagnosed cases of neuro-Behcet's disease were retrospectively analysed in terms of involved site, pattern, signal intensity, contrast enhancement pattern and changes seen on follow-up. Using a 0.35T or 1.0T unit T2-and T1-weighted spin-echocontrast-enhanced images were obtained in six patients. Follow-up MRI after steroid therapy lastion between two weeks and 16 months was performed in six patients. Lesions involved the midbrain(6/7), pons(5/7), thalamus(4/7), medulla oblongata(3/7), tegmentum(3/7), internal capsule(3/7), middle cerebellar peduncle(2/7), dentate nucleus(1/7), basal ganglia(1/7) and temporal lobe(1/7). They were 1-3cm in size, and their shape was ill-defined and patchy. Inhomogeneous high and low signal-intensity was seen on T2-weighted and T1-weighted images, respectively. In two of six cases there was focal mild patchy enhancement. Euring follow-up lasting for between two weeks and 16 months after steroid therapy, the lesions decreased in extent(n=3D5) or disappeared(n=3D1), and in the brainstem, focal brain atrophy occurred in three cases. Although MRI findings of neuro-Behcet's disease are nonspecific, common involvement of the brainstem, tegmentum and internal capsule, as well as improvement on follow-up MRI, may be helpful diagnostic indicators of this condition.=20

  3. ON THE PATH OF THE FILM: Image as Experience and Experience as Image

    Directory of Open Access Journals (Sweden)

    André Reyes Novaes

    2013-12-01

    Full Text Available This article aims to show the relationships between the description of images and the conduction of fieldworks considering a practical pedagogical experience performed with students from the Colégio de Aplicação da UFRJ. Taking as a starting point the research conduct to shoot a documentary called Vulgo Sacopã, which portrayed the transformation of the landscape of a hill situated at Lagoa Rodrigo de Freitas in the city of Rio de Janeiro, the pedagogical practice was divided in two stages. First, students were presented to a series of historical images, seeking to stimulate the reading of the landscape as a "text" and identify variations in its interpretation. Later, we went to the fieldwork in order to perform the landscape and meet the main character of the film. By walking in the paths of the film, it was possible to identify a series of exchanges that can problematize simplistic divisions between the landscape “in visu", shown in the classroom, and the landscape "in situ" observed in the field. RESUMO: O presente artigo tem como objetivo mostrar as relações entre descrição de imagens e trabalho de campo por meio de uma experiência pedagógica prática realizada com alunos do Colégio de Aplicação da UFRJ. Tendo como ponto de partida a pesquisa feita para a execução do documentário Vulgo Sacopã, que retratou as transformações da paisagem de um morro situado na Lagoa Rodrigo de Freitas na cidade do Rio de Janeiro, a prática pedagógica se dividiu em duas etapas. Primeiramente, os alunos foram apresentados a uma série de imagens históricas, buscando estimular a leitura da paisagem como um “texto” e identificar variações na sua interpretação. Posteriormente, foi realizado um trabalho de campo no intuito de percorrer a paisagem estudada e conhecer o personagem principal do filme exibido. Ao percorrer as trilhas do filme com os alunos, foi possível identificar uma série de entrelaçamentos que podem problematizar

  4. Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm: Initial patient experience

    Energy Technology Data Exchange (ETDEWEB)

    Apfaltrer, Paul, E-mail: paul.apfaltrer@medma.uni-heidelberg.de [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Institute of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Schoendube, Harald, E-mail: harald.schoendube@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Allmendinger, Thomas, E-mail: thomas.allmendinger@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); Tricarico, Francesco, E-mail: francescotricarico82@gmail.com [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Department of Bioimaging and Radiological Sciences, Catholic University of the Sacred Heart, “A. Gemelli” Hospital, Largo A. Gemelli 8, Rome (Italy); Schindler, Andreas, E-mail: andreas.schindler@campus.lmu.de [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Vogt, Sebastian, E-mail: sebastian.vogt@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); Sunnegårdh, Johan, E-mail: johan.sunnegardh@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); and others

    2013-02-15

    Objective: To evaluate the effect of a temporal resolution improvement method (TRIM) for cardiac CT on diagnostic image quality for coronary artery assessment. Materials and methods: The TRIM-algorithm employs an iterative approach to reconstruct images from less than 180° of projections and uses a histogram constraint to prevent the occurrence of limited-angle artifacts. This algorithm was applied in 11 obese patients (7 men, 67.2 ± 9.8 years) who had undergone second generation dual-source cardiac CT with 120 kV, 175–426 mAs, and 500 ms gantry rotation. All data were reconstructed with a temporal resolution of 250 ms using traditional filtered-back projection (FBP) and of 200 ms using the TRIM-algorithm. Contrast attenuation and contrast-to-noise-ratio (CNR) were measured in the ascending aorta. The presence and severity of coronary motion artifacts was rated on a 4-point Likert scale. Results: All scans were considered of diagnostic quality. Mean BMI was 36 ± 3.6 kg/m{sup 2}. Average heart rate was 60 ± 9 bpm. Mean effective dose was 13.5 ± 4.6 mSv. When comparing FBP- and TRIM reconstructed series, the attenuation within the ascending aorta (392 ± 70.7 vs. 396.8 ± 70.1 HU, p > 0.05) and CNR (13.2 ± 3.2 vs. 11.7 ± 3.1, p > 0.05) were not significantly different. A total of 110 coronary segments were evaluated. All studies were deemed diagnostic; however, there was a significant (p < 0.05) difference in the severity score distribution of coronary motion artifacts between FBP (median = 2.5) and TRIM (median = 2.0) reconstructions. Conclusion: The algorithm evaluated here delivers diagnostic imaging quality of the coronary arteries despite 500 ms gantry rotation. Possible applications include improvement of cardiac imaging on slower gantry rotation systems or mitigation of the trade-off between temporal resolution and CNR in obese patients.

  5. Initial cathode processing experiences and results for the treatment of spent fuel

    International Nuclear Information System (INIS)

    Westphal, B.R.; Laug, D.V.; Brunsvold, A.R.; Roach, P.D.

    1996-01-01

    As part of the spent fuel treatment demonstration at Argonne National Laboratory, a vacuum distillation process is being employed for the recovery of uranium following an electrorefining process. Distillation of a salt electrolyte, primarily consisting of a eutectic mixture of lithium and potassium chlorides, from uranium is achieved by a batch operation termed ''cathode processing.'' Cathode processing is performed in a retort furnace which enables the production of a stable uranium product that can be isotopically diluted and stored. To date, experiments have been performed with two distillation units; one for prototypical testing and the other for actual spent fuel treatment operations. The results and experiences from these initial experiments with both units will be discussed as well as problems encountered and their resolution

  6. Discharge initiation experiments in the Tokapole II tokamak

    International Nuclear Information System (INIS)

    Shepard, D.A.

    1984-06-01

    Experiments in the Tokapole II tokamak demonstrate the benefits of high density (n/sub e//n 0 greater than or equal to 0.01) preionization by reducing four quantities at startup: necessary toroidal loop voltage (V 1 ) (50%), volt-second consumption (40 to 50%), impurity radiation (25 to 50%), and runaway electron production (approx. 80 to 100%). A zero-dimensional code models the loop voltage reduction dependence on preionization density and predicts a similar result for reactor scale devices. The code shows low initial resistivity and a high resistivity time derivative contribute to loop voltage reduction. The power balance of the ECR plasma in a toroidal-field-only case was studied. Langmuir probes and impurity doping were used. The vertical electric field (E/sub v/) and current (I/sub v/), which result from curvature drift, were measured (E/sub v/ approx. 10 V/cm and I/sub v/ approx. 50 Amps) and exceeded expected values for the bulk electron temperature (approx. 10 eV). A series of experiments with external windings to simulate field errors perpendicular to the toroidal field was done. The results imply that an error field of 0.1% of the toroidal field is deleterious to ECR plasma density

  7. High/Scope Preschool Key Experiences: Initiative and Social Relations. [with] Curriculum Videotape.

    Science.gov (United States)

    Graves, Michelle

    As preschoolers develop the ability to carry out their ideas and play alone and with others, they are developing the foundation for social competence. This booklet and a companion videotape help teachers and parents recognize and support nine High/Scope key experiences in initiative and social relations: (1) making and expressing choices, plans,…

  8. Three-dimensional cardiac cine imaging using the kat ARC acceleration: Initial experience in clinical adult patients at 3T.

    Science.gov (United States)

    Okuda, Shigeo; Yamada, Yoshitake; Tanimoto, Akihiro; Fujita, Jun; Sano, Motoaki; Fukuda, Keiichi; Kuribayashi, Sachio; Jinzaki, Masahiro; Nozaki, Atsushi; Lai, Peng

    2015-09-01

    Three-dimensional cardiac cine imaging has demonstrated promising clinical 1.5-Tesla results; however, its application to 3T scanners has been limited because of the higher sensitivity to off-resonance artifacts. The aim of this study was to apply 3D cardiac cine imaging during a single breath hold in clinical patients on a 3T scanner using the kat ARC (k- and adaptive-t auto-calibrating reconstruction for Cartesian sampling) technique and to evaluate the interchangeability between 2D and 3D cine imaging for cardiac functional analysis and detection of abnormalities in regional wall motion. Following institutional review board approval, we obtained 2D cine images with an acceleration factor of two during multiple breath holds and 3D cine images with a net scan acceleration factor of 7.7 during a single breath hold in 20 patients using a 3T unit. Two readers independently evaluated the wall motion of the left ventricle (LV) using a 5-point scale, and the consistency in the detection of regional wall motion abnormality between 2D and 3D cine was analyzed by Cohen's kappa test. The LV volume was calculated at end-diastole and end-systole (LVEDV, LVESV); the ejection fraction (LVEF) and myocardial weight (LVmass) were also calculated. The relationship between functional parameters calculated for 2D and 3D cine images was analyzed using Pearson's correlation analysis. The bias and 95% limit of agreement (LA) were calculated using Bland-Altman plots. In addition, a qualitative evaluation of image quality was performed with regard to the myocardium-blood contrast, noise level and boundary definition. Despite slight degradation in image quality for 3D cine, excellent agreement was obtained for the detection of wall motion abnormalities between 2D and 3D cine images (κ=0.84 and 0.94 for each reader). Excellent correlations between the two imaging methods were shown for the evaluation of functional parameters (r>0.97). Slight differences in LVEDV, LVESV, LVEF and LVmass

  9. Evaluation of initial uptake and redistribution on stress thallium-201 myocardial perfusion images in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Watanabe, Yoshihiko; Tonooka, Ichiroh; Kanaya, Tohru; Tsuiki, Kai; Yasui, Shouji.

    1984-01-01

    Stress thallium-201 myocardial perfusion imaging was performed on 29 patients with previous myocardial infarction and 29 patients with angina pectoris at exercise to evaluate thallium-201 kinetics in ischemic heart disease. Four views of thallium-201 images (right anterior oblique, antero-posterior, left anterior oblique and left lateral views) were obtained at 5 min after treadmill exercise with administration of 2 mCi of thallium-201 chloride (initial image) and at 3 hours later (delayed image). Myocardial images were divided into 6 segments (anterior, lateral, inferior, posterior, apical and septal segments) and initial uptake (IU) and redistribution index (RDI, the ratio of the maximal washout rate to a washout rate in each segment) were calculated in order to assess the relations of thallium-201 kinetics to wall motion abnormality and coronary artery stenosis. In myocardial infarction, IU and RDI were decreased in proportion to the severity of wall motion abnormality and coronary artery stenosis. Contrarily, in angina pectoris, IU was decreased but RDI was increased proportionally to the severity of coronary arterial stenosis. In conclusion, IU and redistribution of thallium-201 were affected essentially by both the grade of coronary arterial stenosis and the amount of residual viable heart muscle in patients with ischemic myocardial disease. (author)

  10. Characterization of initial events in bacterial surface colonization by two Pseudomonas species using image analysis.

    Science.gov (United States)

    Mueller, R F; Characklis, W G; Jones, W L; Sears, J T

    1992-05-01

    The processes leading to bacterial colonization on solid-water interfaces are adsorption, desorption, growth, and erosion. These processes have been measured individually in situ in a flowing system in real time using image analysis. Four different substrata (copper, silicon, 316 stainless-steel and glass) and 2 different bacterial species (Pseudomonas aeruginosa and Pseudomonas fluorescens) were used in the experiments. The flow was laminar (Re = 1.4) and the shear stress was kept constant during all experiments at 0.75 N m(-2). The surface roughness varied among the substrata from 0.002 microm (for silicon) to 0.015 microm (for copper). Surface free energies varied from 25.1 dynes cm(-1) for silicon to 31.2 dynes cm(-1) for copper. Cell curface hydrophobicity, reported as hydrocarbon partitioning values, ranged from 0.67 for Ps. fluorescens to 0.97 for Ps. aeruginosa.The adsorption rate coefficient varied by as much as a factor of 10 among the combinations of bacterial strain and substratum material, and was positively correlated with surface free energy, the surface roughness of the substratum, and the hydrophobicity of the cells. The probability of desorption decreased with increasing surface free energy and surface roughness of the substratum. Cell growth was inhibited on copper, but replication of cells overlying an initial cell layer was observed with increased exposure time to the cell-containing bulk water. A mathematical model describing cell accumulation on a substratum is presented.

  11. Image compression software for the SOHO LASCO and EIT experiments

    Science.gov (United States)

    Grunes, Mitchell R.; Howard, Russell A.; Hoppel, Karl; Mango, Stephen A.; Wang, Dennis

    1994-01-01

    This paper describes the lossless and lossy image compression algorithms to be used on board the Solar Heliospheric Observatory (SOHO) in conjunction with the Large Angle Spectrometric Coronograph and Extreme Ultraviolet Imaging Telescope experiments. It also shows preliminary results obtained using similar prior imagery and discusses the lossy compression artifacts which will result. This paper is in part intended for the use of SOHO investigators who need to understand the results of SOHO compression in order to better allocate the transmission bits which they have been allocated.

  12. Poetic Experience

    Directory of Open Access Journals (Sweden)

    Shahab Yar Khan

    2014-01-01

    Full Text Available Nature of poetic experience is hereby redefined. The present article initially deals with the perennial nature of true poetic experience and its essential relevance to the world. It attempts to elaborate the process through which a poet is uplifted in a creative moment beyond terrestrial boundaries and is aligned with the ‘state of Perfection'. The role of successive generations of audiences in rediscovering the meaning of a poetic image is defined as life principle of all great poetry. Shakespeare is discussed as the ultimate example of this principle since his popularity remains an irreversible phenomenon

  13. [Characterization of photochemical smog chamber and initial experiments].

    Science.gov (United States)

    Jia, Long; Xu, Yong-Fu; Shi, Yu-Zhen

    2011-02-01

    A self-made new indoor environmental chamber facility for the study of atmospheric processes leading to the formation of ozone and secondary organic aerosols has been introduced and characterized. The characterization experiments include the measurements of wall effects for reactive species and the determination of chamber dependent * OH radical sources by CO-NO(x) irradiation experiments. Preliminary ethene-NO(x) and benzene-NO(x) experiments were conducted as well. The results of characterization experiments show that the wall effects for O3 and NO2 in a new reactor are not obvious. Relative humidity has a great effect on the wall losses in the old reactor, especially for O3. In the old reactor, the rate constant for O3 wall losses is obtained to be 1.0 x 10(-5) s(-1) (RH = 5%) and 4.0 x10(-5) s(-1) (RH = 91%), whereas for NO2, it is 1.0 x 10(-6) s(-1) (RH = 5%) and 0.6 x 10(-6) s(-1) (RH = 75%). The value for k(NO2 --> HONO) determined by CO-NO(x) irradiation experiments is (4.2-5.2) x 10(-5) s(-1) and (2.3-2.5) x 10(-5) s(-1) at RH = 5% and RH 75% -77%, respectively. The average *OH concentration is estimated to be (2.1 +/- 0.4) x 10(6) molecules/cm3 by using a reaction rate coefficient of CO and * OH. The sensitivity of chamber dependent auxiliary reactions to the O3 formation is discussed. Results show that NO2 --> HONO has the greatest impact on the O3 formation during the initial stage, N2O5 + H2O --> 2HNO3 has a minus effect to maximum O3 concentration, and that the wall losses of both O3 and NO2 have little impact on the O3 formation. The results from the ethene-NO(x) and benzene-NO(x) experiments are in good agreement with those from the MCM simulation, which reflects that the facility for the study of the formation of secondary pollution of ozone and secondary organic aerosols is reliable. This demonstrates that our facility can be further used in the deep-going study of chemical processes in the atmosphere.

  14. Cassini Scientist for a Day: a tactile experience

    Science.gov (United States)

    Canas, L.; Altobelli, N.

    2012-09-01

    In September 2011, the Cassini spacecraft took images of three targets and a challenge was launched to all students: to choose the one target they thought would provide the best science and to write an essay explaining their reasons (more information on the "Cassini Scientist for a Day" essay contest official webpage in: http://saturn.jpl.nasa.gov/education/scientistforaday10thedition/, run by NASA/JPL) The three targets presented were: Hyperion, Rhea and Titan, and Saturn. The idea behind "Cassini Scientist for a Day: a tactile experience" was to transform each of these images into schematic tactile images, highlighting relevant features apprehended through a tactile key, accompanied by a small text in Braille with some additional information. This initial approach would allow reach a broader community of students, more specifically those with visual impairment disabilities. Through proper implementation and careful study cases the adapted images associated with an explanatory key provide more resources in tactile astronomy. As the 2012 edition approaches a new set of targeted objet images will be once again transformed and adapted to visually impaired students and will aim to reach more students into participate in this international competition and to engage them in a quest to expand their knowledge in the amazing Cassini discoveries and the wonders of Saturn and its moons. As the winning essays will be published on the Cassini website and contest winners invited to participate in a dedicated teleconference with Cassini scientists from NASA's Jet Propulsion Laboratory, this initiative presents a great chance to all visually impaired students and teachers to participate in an exciting experience. These initiatives must be complemented with further information to strengthen the learning experience. However they stand as a good starting point to tackle further astronomical concepts in the classroom, especially this field that sometimes lacks the resources. Although

  15. Ethernet image communication performance in a multimodal PACS network

    International Nuclear Information System (INIS)

    Lou, S.L.; Valentino, D.J.; Chan, K.K.; Huang, H.K.

    1989-01-01

    The authors have evaluated the performance of an Ethernet network in a multimodal picture archiving and communications system (PACS) environment. The study included measurements between Sun workstations and PC- AT computers running communication software at the TCP level. First they initiated image transfers between two workstations, a server and a client. Next, they successively added clients to transfer images to the server and they measured degradation in network performance. Finally, they initiated image transfers between pairs of workstations and again measured performance degradation. The results of the authors' experiments indicate that Ethernet is suitable for image communication only in limited network situations. They discuss how to maximize network performance given these constraints

  16. Experience of Initial Symptoms of Breast Cancer and Triggers for Action in Ethiopia

    International Nuclear Information System (INIS)

    Dye, T.D.; Hobden, C.; Reeler, A.; Dye, T.D.; Bogale, S.; Tilahun, Y.; Deressa, T.

    2012-01-01

    Objective. This study assessed the initial experiences, symptoms, and actions of patients in Ethiopia ultimately determined to have breast cancer. Methods. 69 participants in a comprehensive breast cancer treatment program at the main national cancer hospital in Ethiopia were interviewed using mixed qualitative and quantitative approaches. Participants narratives of their initial cancer experience were coded and analyzed for themes around their symptoms, time to seeking advice, triggers for action, and contextual factors. The assessment was approved by the Addis Ababa University Faculty of Medicine Institutional Review Board. Results. Nearly all women first noticed lumps, though few sought medical advice within the first year (average time to action: 1.5 years). Eventually, changes in their symptoms motivated most participants to seek advice. Most participants did not think the initial lump would be cancer, nor was a lump of any particular concern until symptoms changed. Conclusion. Given the frequency with which lumps are the first symptom noticed, raising awareness among participants that lumps should trigger medical consultation could contribute significantly to more rapid medical advice-seeking among women in Ethiopia. Primary care sites should be trained and equipped to offer evaluation of lumps so that women can be referred appropriately for assessment if needed

  17. Comparison of initial and delayed myocardial imaging with beta-methyl-p-[123I]-iodophenylpentadecanoic acid in acute myocardial infarction

    International Nuclear Information System (INIS)

    Naruse, Hitoshi; Yoshimura, Noriko; Yamamoto, Juro; Morita, Masato; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru

    1994-01-01

    Myocardial imaging using β-methyl-p-[ 123 I]-iodophenylpentadecanoic acid (BMIPP) of 15 patients with acute myocardial infarction was performed to assess 'fill-in' and 'washout' defects in the delayed myocardial image. The initial and delayed images were evaluated by a visual and quantitative washout rate method. Visual judgement found 8/180 (4%) segments showed 'fill-in' defects, and 24/180 segments (13%) showed 'washout' defects. There was no relationship between days from onset to the study and the frequency of fill-in and washout defects. The mean washout rate in the segments with 'fill-in' defects was 9.0±16.6%, and that of 'washout' defects was 24.9±18.1% which was significantly higher than in controls (8.7±15.4%, p<0.05). There was no correlation between mean washout rate and total blood lipids, total cholesterol, triglyceride and HDL-cholesterol. Therefore, neither time from onset nor blood lipids level was related to changes from the initial image to the delayed image. These changes may be due to relative (false) findings due to changes in circumference, and may be based on myocardial characteristics after myocardial infarction and/or reperfusion. (author)

  18. [Comparison of initial and delayed myocardial imaging with beta-methyl-p-[123I]-iodophenylpentadecanoic acid in acute myocardial infarction].

    Science.gov (United States)

    Naruse, H; Yoshimura, N; Yamamoto, J; Morita, M; Fukutake, N; Ohyanagi, M; Iwasaki, T; Fukuchi, M

    1994-01-01

    Myocardial imaging using beta-methyl-p-[123I]-iodophenylpentadecanoic acid (BMIPP) of 15 patients with acute myocardial infarction was performed to assess "fill-in" and "washout" defects in the delayed myocardial image. The initial and delayed images were evaluated by a visual and quantitative washout rate method. Visual judgement found 8/180 (4%) segments showed "fill-in" defects, and 24/180 segments (13%) showed "washout" defects. There was no relationship between days from onset to the study and the frequency of fill-in and washout defects. The mean washout rate in the segments with "fill-in" defects was 9.0 +/- 16.6%, and that of "washout" defects was 24.9 +/- 18.1% which was significantly higher than in controls (8.7 +/- 15.4%, p < 0.05). There was no correlation between mean washout rate and total blood lipids, total cholesterol, triglyceride and HDL-cholesterol. Therefore, neither time from onset nor blood lipids level was related to changes from the initial image to the delayed image. These changes may be due to relative (false) findings due to changes in circumference, and may be based on myocardial characteristics after myocardial infarction and/or reperfusion.

  19. MR imaging of right ventricular function after the Ross procedure for aortic valve replacement: initial experience

    NARCIS (Netherlands)

    Grotenhuis, Heynric B.; de Roos, Albert; Ottenkamp, Jaap; Schoof, Paul H.; Vliegen, Hubert W.; Kroft, Lucia J. M.

    2008-01-01

    PURPOSE: To prospectively assess right ventricular (RV) function after the Ross procedure by using magnetic resonance (MR) imaging. MATERIALS AND METHODS: The local ethics committee approved the study and informed consent was obtained from all participants prior to enrollment in the study. Seventeen

  20. Initial investigation into lower-cost CT for resource limited regions of the world

    Science.gov (United States)

    Dobbins, James T., III; Wells, Jered R.; Segars, W. Paul; Li, Christina M.; Kigongo, Christopher J. N.

    2010-04-01

    This paper describes an initial investigation into means for producing lower-cost CT scanners for resource limited regions of the world. In regions such as sub-Saharan Africa, intermediate level medical facilities serving millions have no CT machines, and lack the imaging resources necessary to determine whether certain patients would benefit from being transferred to a hospital in a larger city for further diagnostic workup or treatment. Low-cost CT scanners would potentially be of immense help to the healthcare system in such regions. Such scanners would not produce state-of-theart image quality, but rather would be intended primarily for triaging purposes to determine the patients who would benefit from transfer to larger hospitals. The lower-cost scanner investigated here consists of a fixed digital radiography system and a rotating patient stage. This paper describes initial experiments to determine if such a configuration is feasible. Experiments were conducted using (1) x-ray image acquisition, a physical anthropomorphic chest phantom, and a flat-panel detector system, and (2) a computer-simulated XCAT chest phantom. Both the physical phantom and simulated phantom produced excellent image quality reconstructions when the phantom was perfectly aligned during acquisition, but artifacts were noted when the phantom was displaced to simulate patient motion. An algorithm was developed to correct for motion of the phantom and demonstrated success in correcting for 5-mm motion during 360-degree acquisition of images. These experiments demonstrated feasibility for this approach, but additional work is required to determine the exact limitations produced by patient motion.

  1. [Initiation, promotion, initiation experiments with radon and cigarette smoke: Lung tumors in rats]. Progress report

    International Nuclear Information System (INIS)

    Moolgavkar, S.H.

    1994-01-01

    During the past several years, the authors have made considerable progress in modeling carcinogenesis in general, and in modeling radiation carcinogenesis, in particular. They present an overview of their progress in developing stochastic carcinogenesis models and applying them to experimental and epidemiologic data sets. Traditionally, cancer models have been used for the analysis of incidence (or prevalence) data in epidemiology and time to tumor data in experimental studies. The relevant quantities for the analysis of these data are the hazard function and the probability of tumor. The derivation of these quantities is briefly described here. More recently, the authors began to use these models for the analysis of data on intermediate lesions on the pathway to cancer. Such data are available in experimental carcinogenesis studies, in particular in initiation and promotion studies on the mouse skin and the rat liver. If however, quantitative information on intermediate lesions on the pathway to lung cancer were to be come available at some future date, the methods that they have developed for the analysis of initiation-promotion experiments could easily be applied to the analysis of these lesions. The mathematical derivations here are couched in terms of a particular two-mutation model of carcinogenesis. Extension to models postulating more than two mutations is not always straightforward

  2. Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects

    International Nuclear Information System (INIS)

    Huang, Ambrose J.; Chang, Connie Y.; Palmer, William E.; Thomas, Bijoy J.; MacMahon, Peter J.

    2015-01-01

    To prospectively evaluate a dedicated extremity cone-beam CT (CBCT) scanner in cases with and without orthopedic hardware by (1) comparing its imaging duration and image quality to those of radiography and multidetector CT (MDCT) and (2) comparing its radiation dose to that of MDCT. Written informed consent was obtained for all subjects for this IRB-approved, HIPAA-compliant study. Fifty subjects with (1) fracture of small bones, (2) suspected intraarticular fracture, (3) fracture at the site of complex anatomy, or (4) a surgical site difficult to assess with radiography alone were recruited and scanned on an extremity CBCT scanner prior to FDA approval. Same-day radiographs were performed in all subjects. Some subjects also underwent MDCT within 1 month of CBCT. Imaging duration and image quality were compared between CBCT and radiographs. Imaging duration, effective radiation dose, and image quality were compared between CBCT and MDCT. Fifty-one CBCT scans were performed in 50 subjects. Average imaging duration was shorter for CBCT than radiographs (4.5 min vs. 6.6 min, P = 0.001, n = 51) and MDCT (7.6 min vs. 10.9 min, P = 0.01, n = 7). Average estimated effective radiation dose was less for CBCT than MDCT (0.04 mSv vs. 0.13 mSv, P = 0.02, n = 7). CBCT images yielded more diagnostic information than radiographs in 23/51 cases and more diagnostic information than MDCT in 1/7 cases, although radiographs were superior for detecting hardware complications. CBCT performs high-resolution imaging of the extremities using less imaging time than radiographs and MDCT and lower radiation dose than MDCT. (orig.)

  3. Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Ambrose J.; Chang, Connie Y.; Palmer, William E. [Massachusetts General Hospital, Department of Radiology, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States); Thomas, Bijoy J. [Universal College of Medical Sciences, Department of Radiology, Bhairahawa (Nepal); MacMahon, Peter J. [Mater Misericordiae University Hospital, Department of Radiology, Dublin 7 (Ireland)

    2015-06-01

    To prospectively evaluate a dedicated extremity cone-beam CT (CBCT) scanner in cases with and without orthopedic hardware by (1) comparing its imaging duration and image quality to those of radiography and multidetector CT (MDCT) and (2) comparing its radiation dose to that of MDCT. Written informed consent was obtained for all subjects for this IRB-approved, HIPAA-compliant study. Fifty subjects with (1) fracture of small bones, (2) suspected intraarticular fracture, (3) fracture at the site of complex anatomy, or (4) a surgical site difficult to assess with radiography alone were recruited and scanned on an extremity CBCT scanner prior to FDA approval. Same-day radiographs were performed in all subjects. Some subjects also underwent MDCT within 1 month of CBCT. Imaging duration and image quality were compared between CBCT and radiographs. Imaging duration, effective radiation dose, and image quality were compared between CBCT and MDCT. Fifty-one CBCT scans were performed in 50 subjects. Average imaging duration was shorter for CBCT than radiographs (4.5 min vs. 6.6 min, P = 0.001, n = 51) and MDCT (7.6 min vs. 10.9 min, P = 0.01, n = 7). Average estimated effective radiation dose was less for CBCT than MDCT (0.04 mSv vs. 0.13 mSv, P = 0.02, n = 7). CBCT images yielded more diagnostic information than radiographs in 23/51 cases and more diagnostic information than MDCT in 1/7 cases, although radiographs were superior for detecting hardware complications. CBCT performs high-resolution imaging of the extremities using less imaging time than radiographs and MDCT and lower radiation dose than MDCT. (orig.)

  4. Radiation therapists' perceptions of the minimum level of experience required to perform portal image analysis

    International Nuclear Information System (INIS)

    Rybovic, Michala; Halkett, Georgia K.; Banati, Richard B.; Cox, Jennifer

    2008-01-01

    Background and purpose: Our aim was to explore radiation therapists' views on the level of experience necessary to undertake portal image analysis and clinical decision making. Materials and methods: A questionnaire was developed to determine the availability of portal imaging equipment in Australia and New Zealand. We analysed radiation therapists' responses to a specific question regarding their opinion on the minimum level of experience required for health professionals to analyse portal images. We used grounded theory and a constant comparative method of data analysis to derive the main themes. Results: Forty-six radiation oncology facilities were represented in our survey, with 40 questionnaires being returned (87%). Thirty-seven radiation therapists answered our free-text question. Radiation therapists indicated three main themes which they felt were important in determining the minimum level of experience: 'gaining on-the-job experience', 'receiving training' and 'working as a team'. Conclusions: Radiation therapists indicated that competence in portal image review occurs via various learning mechanisms. Further research is warranted to determine perspectives of other health professionals, such as radiation oncologists, on portal image review becoming part of radiation therapists' extended role. Suitable training programs and steps for implementation should be developed to facilitate this endeavour

  5. Preliminary experiment of fast neutron imaging with direct-film method

    International Nuclear Information System (INIS)

    Pei Yuyang; Tang Guoyou; Guo Zhiyu; Zhang Guohui

    2005-01-01

    A preliminary experiment is conducted with direct-film method under the condition that fast neutron is generated by the reaction of 9 Be(d, n) on the Beijing University 4.5 MV Van de Graaff, whose energy is lower than 7 MeV. Basic characteristics of direct-film neutron radiography system are investigated with the help of samples in different materials, different thickness and holes of different diameter. The fast neutron converter, which is vital for fast neutron imaging, is produced with the materials made in China. The result indicates that fast neutron converter can meet the requirement of fast neutron imaging; further research of fast neutron imaging can be conducted on the accelerator and neutron-generator in China. (authors)

  6. Mapping patients' experiences from initial symptoms to gout diagnosis: a qualitative exploration.

    Science.gov (United States)

    Liddle, Jennifer; Roddy, Edward; Mallen, Christian D; Hider, Samantha L; Prinjha, Suman; Ziebland, Sue; Richardson, Jane C

    2015-09-14

    To explore patients' experiences from initial symptoms to receiving a diagnosis of gout. Data from in-depth semistructured interviews were used to construct themes to describe key features of patients' experiences of gout diagnosis. A maximum variation sample of 43 UK patients with gout (29 men; 14 women; age range 32-87 years) were recruited from general practices, rheumatology clinics, gout support groups and through online advertising. Severe joint pain, combined with no obvious signs of physical trauma or knowledge of injury, caused confusion for patients attempting to interpret their symptoms. Reasons for delayed consultation included self-diagnosis and/or self-medication, reluctance to seek medical attention, and financial/work pressures. Factors potentially contributing to delayed diagnosis after consultation included reported misdiagnosis, attacks in joints other than the first metatarsophalangeal joint, and female gender. The limitations in using serum uric acid (SUA) levels for diagnostic purposes were not always communicated effectively to patients, and led to uncertainty and lack of confidence in the accuracy of the diagnosis. Resistance to the diagnosis occurred in response to patients' beliefs about the causes of gout and characteristics of the people likely to be affected. Diagnosis prompted actions, such as changes in diet, and evidence was found of self-monitoring of SUA levels. This study is the first to report data specifically about patients' pathways to initial consultation and subsequent experiences of gout diagnosis. A more targeted approach to information provision at diagnosis would improve patients' experiences. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Searching for an alternative oral contrast agent for GI tract MR imaging; in vitro phase, initial report

    International Nuclear Information System (INIS)

    Okla, W.; Szeszkowski, W.; Cieszanowski, A.; Golebiowski, M.

    2002-01-01

    MR has been recently considered to be suitable method for detection GI tract pathologies. A few substances (some of a natural origin) seem to act as an efficient oral MR contrast agents. The aim of this study is to find an alternative substance, which can be administrated orally to patients in order to enhance signal intensity (SI). The ideal agent should have a biphase pattern (high SI in T1 and low in T2), and should be nontoxic and cost effective. Phantom experiments were conducted with 1.5 T MR scanner. T1W and T2W sequences were used for initial estimation. Number of different agents such as: water, Gd-DTPA, barium sulfate, green tea, blueberry juice, cranberry juice, blackcurrant juice, and some more were evaluated. Signal intensity was measured by using elliptical region of interest (ROI). MR imaging in one patient with stomach cancer was also performed. In T1W-FFE sequence cranberry juice reached satisfactorily high signal (SI=1760.14). In T2W-TSE sequence this substance reduced signal intensity (SI=23.10) almost to background level. Blueberry juice appear to be the next substance capable to generate high signal (SI=1558.31) in T1W sequence (T1-TSE). MR examination of a patient with stomach adenocarcinoma (using blueberry juice as an oral contrast agent) satisfactorily depicted and delineated tumor mass on both: T1W and T2W images. Cranberry juice and blueberry juice seemed to act effectively as oral contrast agents for gastrointestinal MR imaging. Thus they need further exploration and trials. (author)

  8. Online imaging of initial DNA damages at the PTB microbeam

    International Nuclear Information System (INIS)

    Giesen, U.; Langner, F.; Mielke, C.; Mosconi, M.; Dirks, W. G.

    2011-01-01

    In an inter-disciplinary collaboration of Physikalisch-Technische Bundesanstalt (PTB), German Collection of Microorganisms and Cell Cultures (DSMZ) and Heinrich-Heine Univ., live-cell imaging has been established at the charged-particle microbeam facility of PTB. Candidate genes participating in DNA strand-break repair pathways such as PARP-1, MRE11, MSH2, MDC1 and p53BP1 have been modified to generate fluorescent fusion proteins. Using multi-cistronic expression vectors, stable genomic integration was achieved in HT-1080 fibroblasts. The aim of this study is to characterise and use these highly reliable cell lines for studying initial steps of DNA damage responses and kinetics of repair after microbeam irradiation with high- and low-linear energy transfer (LET) particles in living cells at physiological conditions. (authors)

  9. SU-E-J-58: Comparison of Conformal Tracking Methods Using Initial, Adaptive and Preceding Image Frames for Image Registration

    Energy Technology Data Exchange (ETDEWEB)

    Teo, P; Guo, K; Alayoubi, N; Kehler, K; Pistorius, S [CancerCare Manitoba, Winnipeg, MB (Canada)

    2015-06-15

    Purpose: Accounting for tumor motion during radiation therapy is important to ensure that the tumor receives the prescribed dose. Increasing the field size to account for this motion exposes the surrounding healthy tissues to unnecessary radiation. In contrast to using motion-encompassing techniques to treat moving tumors, conformal radiation therapy (RT) uses a smaller field to track the tumor and adapts the beam aperture according to the motion detected. This work investigates and compares the performance of three markerless, EPID based, optical flow methods to track tumor motion with conformal RT. Methods: Three techniques were used to track the motions of a 3D printed lung tumor programmed to move according to the tumor of seven lung cancer patients. These techniques utilized a multi-resolution optical flow algorithm as the core computation for image registration. The first method (DIR) registers the incoming images with an initial reference frame, while the second method (RFSF) uses an adaptive reference frame and the third method (CU) uses preceding image frames for registration. The patient traces and errors were evaluated for the seven patients. Results: The average position errors for all patient traces were 0.12 ± 0.33 mm, −0.05 ± 0.04 mm and −0.28 ± 0.44 mm for CU, DIR and RFSF method respectively. The position errors distributed within 1 standard deviation are 0.74 mm, 0.37 mm and 0.96 mm respectively. The CU and RFSF algorithms are sensitive to the characteristics of the patient trace and produce a wider distribution of errors amongst patients. Although the mean error for the DIR method is negatively biased (−0.05 mm) for all patients, it has the narrowest distribution of position error, which can be corrected using an offset calibration. Conclusion: Three techniques of image registration and position update were studied. Using direct comparison with an initial frame yields the best performance. The authors would like to thank Dr.YeLin Suh for

  10. SU-E-J-58: Comparison of Conformal Tracking Methods Using Initial, Adaptive and Preceding Image Frames for Image Registration

    International Nuclear Information System (INIS)

    Teo, P; Guo, K; Alayoubi, N; Kehler, K; Pistorius, S

    2015-01-01

    Purpose: Accounting for tumor motion during radiation therapy is important to ensure that the tumor receives the prescribed dose. Increasing the field size to account for this motion exposes the surrounding healthy tissues to unnecessary radiation. In contrast to using motion-encompassing techniques to treat moving tumors, conformal radiation therapy (RT) uses a smaller field to track the tumor and adapts the beam aperture according to the motion detected. This work investigates and compares the performance of three markerless, EPID based, optical flow methods to track tumor motion with conformal RT. Methods: Three techniques were used to track the motions of a 3D printed lung tumor programmed to move according to the tumor of seven lung cancer patients. These techniques utilized a multi-resolution optical flow algorithm as the core computation for image registration. The first method (DIR) registers the incoming images with an initial reference frame, while the second method (RFSF) uses an adaptive reference frame and the third method (CU) uses preceding image frames for registration. The patient traces and errors were evaluated for the seven patients. Results: The average position errors for all patient traces were 0.12 ± 0.33 mm, −0.05 ± 0.04 mm and −0.28 ± 0.44 mm for CU, DIR and RFSF method respectively. The position errors distributed within 1 standard deviation are 0.74 mm, 0.37 mm and 0.96 mm respectively. The CU and RFSF algorithms are sensitive to the characteristics of the patient trace and produce a wider distribution of errors amongst patients. Although the mean error for the DIR method is negatively biased (−0.05 mm) for all patients, it has the narrowest distribution of position error, which can be corrected using an offset calibration. Conclusion: Three techniques of image registration and position update were studied. Using direct comparison with an initial frame yields the best performance. The authors would like to thank Dr.YeLin Suh for

  11. Corporate social investment and a company’s image: A case of a CSI initiative in a South African low income community

    Directory of Open Access Journals (Sweden)

    Paul-Francois Muzindutsi

    2015-11-01

    Full Text Available One of the goals of corporate social investment (CSI is to ensure that a company becomes a responsible entity which acts as a conscientious citizen within a society. CSI plays an important role in enhancing how a company is perceived within the community it operates in. This paper used a combination of qualitative and quantitative research designs to investigate the effect of a specific CSI initiative on a company’s image within a low income community in South Africa. Semi-structured interviews and survey questionnaire were used to collect data from community members in the township of Bophelong, South Africa. Results show that, if adequately managed, CSI initiatives tend to enhance company’s image as well as its relations with the community it operates in. However, if not adequately managed CSI can created unreachable expectations that can negatively affect a company’s image. Thus, companies better manage their CSI initiatives have an increased opportunity to enhance their reputation within the community they operate in.

  12. BgCut: Automatic Ship Detection from UAV Images

    Directory of Open Access Journals (Sweden)

    Chao Xu

    2014-01-01

    foreground objects from sea automatically. First, a sea template library including images in different natural conditions is built to provide an initial template to the model. Then the background trimap is obtained by combing some templates matching with region growing algorithm. The output trimap initializes Grabcut background instead of manual intervention and the process of segmentation without iteration. The effectiveness of our proposed model is demonstrated by extensive experiments on a certain area of real UAV aerial images by an airborne Canon 5D Mark. The proposed algorithm is not only adaptive but also with good segmentation. Furthermore, the model in this paper can be well applied in the automated processing of industrial images for related researches.

  13. Improving appropriate use of echocardiography and single-photon emission computed tomographic myocardial perfusion imaging: a continuous quality improvement initiative.

    Science.gov (United States)

    Johnson, Thomas V; Rose, Geoffrey A; Fenner, Deborah J; Rozario, Nigel L

    2014-07-01

    Appropriate use criteria for cardiovascular imaging have been published, but compliance in practice has been incomplete, with persistent high rates of inappropriate use. The aim of this study was to show the efficacy of a continuous quality improvement (CQI) initiative to favorably influence the appropriate use of outpatient transthoracic echocardiography and single-photon emission computed tomographic (SPECT) myocardial perfusion imaging (MPI) in a large cardiovascular practice. In this prospective study, a multiphase CQI initiative was implemented, and its impact on ordering patterns for outpatient transthoracic echocardiography and SPECT MPI was assessed. Between November and December 2010, a baseline analysis of the application of appropriate use criteria to indications for outpatient transthoracic echocardiographic studies (n = 203) and SPECT MPI studies (n = 205) was performed, with studies categorized as "appropriate," "inappropriate," "uncertain," or "unclassified." The CQI initiative was then begun, with (1) clinician education, including didactic lectures and case-based presentations with audience participation; (2) system changes in ordering processes, with redesigned image ordering forms; and (3) peer review and feedback. A follow-up analysis was then performed between June and August 2012, with categorization of indications for transthoracic echocardiographic studies (n = 206) and SPECT MPI studies (n = 206). At baseline, 73.9% of echocardiographic studies were categorized as appropriate, 16.7% as inappropriate, 5.9% as uncertain, and 3.4% as unclassified. Similarly, for SPECT MPI studies 71.7% were categorized as appropriate, 18.5% as inappropriate, 7.8% as uncertain, and 1.9% as unclassified. Separate analysis of the two most important categories, appropriate and inappropriate, demonstrated a significant improvement after the CQI initiative, with a 63% reduction in inappropriate echocardiographic studies (18.5% vs 6.9%, P = .0010) and a 46% reduction

  14. SPINAL CORD STIMULATION IN TREATMENT OF THE NEUROPATHIC PAIN SYNDROMES: INITIAL EXPERIENCE

    Directory of Open Access Journals (Sweden)

    D. A. Rzaev

    2010-01-01

    Full Text Available In the article initial experience of spinal cord stimulation for chronic pain syndromes is described. The trial was done for 62 patients, in 52 cases trial was successful and subcutaneous pulse generator were implanated. Maximal follow-up is 26 months. The level of pain evaluates at VAS. Permanent pain-relieve results were achieved in 46 patients (74,2%. These results correspond to literature data.

  15. The experience of initiating injection drug use and its social context: a qualitative systematic review and thematic synthesis.

    Science.gov (United States)

    Guise, Andy; Horyniak, Danielle; Melo, Jason; McNeil, Ryan; Werb, Dan

    2017-12-01

    Understanding the experience of initiating injection drug use and its social contexts is crucial to inform efforts to prevent transitions into this mode of drug consumption and support harm reduction. We reviewed and synthesized existing qualitative scientific literature systematically to identify the socio-structural contexts for, and experiences of, the initiation of injection drug use. We searched six databases (Medline, Embase, PsychINFO, CINAHL, IBSS and SSCI) systematically, along with a manual search, including key journals and subject experts. Peer-reviewed studies were included if they qualitatively explored experiences of or socio-structural contexts for injection drug use initiation. A thematic synthesis approach was used to identify descriptive and analytical themes throughout studies. From 1731 initial results, 41 studies reporting data from 1996 participants were included. We developed eight descriptive themes and two analytical (higher-order) themes. The first analytical theme focused on injecting initiation resulting from a social process enabled and constrained by socio-structural factors: social networks and individual interactions, socialization into drug-using identities and choices enabled and constrained by social context all combine to produce processes of injection initiation. The second analytical theme addressed pathways that explore varying meanings attached to injection initiation and how they link to social context: seeking pleasure, responses to increasing tolerance to drugs, securing belonging and identity and coping with pain and trauma. Qualitative research shows that injection drug use initiation has varying and distinct meanings for individuals involved and is a dynamic process shaped by social and structural factors. Interventions should therefore respond to the socio-structural influences on injecting drug use initiation by seeking to modify the contexts for initiation, rather than solely prioritizing the reduction of individual

  16. Initial experiment of focusing wiggler of MM wave Free Electron Laser on LAX-1

    International Nuclear Information System (INIS)

    Sakamoto, Keishi; Maebara, Sunao; Watanabe, Akihiko; Kishimoto, Yasuaki; Nagashima, Takashi; Maeda, Hikosuke; Shiho, Makoto; Oda, Hisako; Kawasaki, Sunao.

    1991-03-01

    Initial results of Free Electron laser (FEL) Experiment in the mm wave region are presented. The experiment is carried out using a induction linac system (LAX-1: Large current Accelerator Experiment) of E b = 1 MeV, Ib = 1 ∼ 3 kA. The wiggler of FEL is composed of the curved surface magnets arrays (focusing wiggler), which is found to be effective for a transport of low energy and high current beam through the wiggler. The superradiance of the mm wave region (30 GHz ∼ 40 GHz) is observed. The growth rate of this radiation is 0.42 dB/cm. (author)

  17. Initial experience with a handheld device digital imaging and communications in medicine viewer: OsiriX mobile on the iPhone.

    Science.gov (United States)

    Choudhri, Asim F; Radvany, Martin G

    2011-04-01

    Medical imaging is commonly used to diagnose many emergent conditions, as well as plan treatment. Digital images can be reviewed on almost any computing platform. Modern mobile phones and handheld devices are portable computing platforms with robust software programming interfaces, powerful processors, and high-resolution displays. OsiriX mobile, a new Digital Imaging and Communications in Medicine viewing program, is available for the iPhone/iPod touch platform. This raises the possibility of mobile review of diagnostic medical images to expedite diagnosis and treatment planning using a commercial off the shelf solution, facilitating communication among radiologists and referring clinicians.

  18. Clinical indications for high-field 1.5 T intraoperative magnetic resonance imaging and neuro-navigation for neurosurgical procedures. Review of initial 100 cases

    International Nuclear Information System (INIS)

    Maesawa, Satoshi; Nakahara, Norimoto; Watanabe, Tadashi; Fujii, Masazumi; Saito, Kiyoshi; Kajita, Yasukazu; Nagatani, Tetsuya; Wakabayashi, Toshihiko; Yoshida, Jun

    2009-01-01

    Initial experiences are reviewed in an integrated operation theater equipped with an intraoperative high-field (1.5 T) magnetic resonance (MR) imager and neuro-navigation (BrainSUITE), to evaluate the indications and limitations. One hundred consecutive cases were treated, consisting of 38 gliomas, 49 other tumors, 11 cerebrovascular diseases, and 2 functional diseases. The feasibility and usefulness of the integrated theater were evaluated for individual diseases, focusing on whether intraoperative images (including diffusion tensor imaging) affected the surgical strategy. The extent of resection and outcomes in each histological category of brain tumors were examined. Intraoperative high-field MR imaging frequently affected or modified the surgical strategy in the glioma group (27/38 cases, 71.1%), but less in the other tumor group (13/49 cases, 26.5%). The surgical strategy was not modified in cerebrovascular or functional diseases, but the success of procedures and the absence of complications could be confirmed. In glioma surgery, subtotal or greater resection was achieved in 22 of the 31 patients (71%) excluding biopsies, and intraoperative images revealed tumor remnants resulting in the extension of resection in 21 of the 22 patients (95.4%), the highest rate of extension among all types of pathologies. The integrated neuro-navigation improved workflow. The best indication for intraoperative high-field MR imaging and integrated neuro-navigation is brain tumors, especially gliomas, and is supplementary in assuring quality in surgery for cerebrovascular or functional diseases. Immediate quality assurance is provided in several types of neurosurgical procedures. (author)

  19. Oculomotor evidence for top-down control following the initial saccade.

    Directory of Open Access Journals (Sweden)

    Alisha Siebold

    Full Text Available The goal of the current study was to investigate how salience-driven and goal-driven processes unfold during visual search over multiple eye movements. Eye movements were recorded while observers searched for a target, which was located on (Experiment 1 or defined as (Experiment 2 a specific orientation singleton. This singleton could either be the most, medium, or least salient element in the display. Results were analyzed as a function of response time separately for initial and second eye movements. Irrespective of the search task, initial saccades elicited shortly after the onset of the search display were primarily salience-driven whereas initial saccades elicited after approximately 250 ms were completely unaffected by salience. Initial saccades were increasingly guided in line with task requirements with increasing response times. Second saccades were completely unaffected by salience and were consistently goal-driven, irrespective of response time. These results suggest that stimulus-salience affects the visual system only briefly after a visual image enters the brain and has no effect thereafter.

  20. Digital breast tomosynthesis (DBT): initial experience in a clinical setting

    International Nuclear Information System (INIS)

    Skaane, Per; Gullien, Randi; Eben, Ellen B.; Haakenaasen, Unni; Naess Jebsen, Ingvild; Krager, Mona; Bjoerndal, Hilde; Ekseth, Ulrika; Jahr, Gunnar

    2012-01-01

    Background: Digital breast tomosynthesis (DBT) is a promising new technology. Some experimental clinical studies have shown positive results, but the future role and indications of this new technique, whether in a screening or clinical setting, need to be evaluated. Purpose: To compare digital mammography and DBT in a side-by-side feature analysis for cancer conspicuity, and to assess whether there is a potential additional value of DBT to standard state-of-the-art conventional imaging work-up with respect to detection of additional malignancies. Material and Methods: The study had ethics committee approval. A total of 129 women underwent 2D digital mammography including supplementary cone-down and magnification views and breast ultrasonography if indicated, as well as digital breast tomosynthesis. The indication for conventional imaging in the clinical setting included a palpable lump in 30 (23%), abnormal mammographic screening findings in 54 (42%), and surveillance in 45 (35%) of the women. The women were examined according to present guidelines, including spot-magnification views, ultrasonography, and needle biopsies, if indicated. The DBT examinations were interpreted several weeks after the conventional imaging without knowledge of the conventional imaging findings. In a later session, three radiologists performed a side-by-side feature analysis for cancer conspicuity in a sample of 50 cases. Results: State-of-the-art conventional imaging resulted in needle biopsy of 45 breasts, of which 20 lesions were benign and a total of 25 cancers were diagnosed. The remaining 84 women were dismissed with a normal/definitely benign finding and without indication for needle biopsy. The subsequent DBT interpretation found suspicious findings in four of these 84 women, and these four women had to be called back for repeated work-up with knowledge of the tomosynthesis findings. These delayed work-ups resulted in two cancers (increasing the cancer detection by 8%) and two

  1. CLASSIFICATION OF CROP-SHELTER COVERAGE BY RGB AERIAL IMAGES: A COMPENDIUM OF EXPERIENCES AND FINDINGS

    Directory of Open Access Journals (Sweden)

    Claudia Arcidiacono

    2010-09-01

    Full Text Available Image processing is a powerful tool apt to perform selective data extraction from high-content images. In agricultural studies, image processing has been applied to different scopes, among them the classification of crop shelters has been recently considered especially in areas where there is a lack of public control in the building activity. The application of image processing to crop-shelter feature recognition make it possible to automatically produce thematic maps that constitute a basic knowledge for local authorities to cope with environmental problems and for technicians to be used in their planning activity. This paper reviews the authors’ experience in the definition of methodologies, based on the main image processing methods, for crop-shelter feature extraction from aerial digital images. Some experiences of pixel-based and object-oriented methods are described and discussed. The results show that the methodology based on object-oriented methods improves crop-shelter classification and reduces computational time, compared to pixel-based methodologies.

  2. Intraoperative Scintigraphy Using a Large Field-of-View Portable Gamma Camera for Primary Hyperparathyroidism: Initial Experience

    Directory of Open Access Journals (Sweden)

    Nathan C. Hall

    2015-01-01

    Full Text Available Background. We investigated a novel technique, intraoperative 99 mTc-Sestamibi (MIBI imaging (neck and excised specimen (ES, using a large field-of-view portable gamma camera (LFOVGC, for expediting confirmation of MIBI-avid parathyroid adenoma removal. Methods. Twenty patients with MIBI-avid parathyroid adenomas were preoperatively administered MIBI and intraoperatively imaged prior to incision (neck and immediately following resection (neck and/or ES. Preoperative and intraoperative serum parathyroid hormone monitoring (IOPTH and pathology (path were also performed. Results. MIBI neck activity was absent and specimen activity was present in 13/20 with imaging after initial ES removal. In the remaining 7/20 cases, residual neck activity and/or absent ES activity prompted excision of additional tissue, ultimately leading to complete hyperfunctioning tissue excision. Postexcision LFOVGC ES imaging confirmed parathyroid adenoma resection 100% when postresection imaging qualitatively had activity (ES and/or no activity (neck. The mean ± SEM time saving using intraoperative LFOVGC data to confirm resection versus first IOPTH or path result would have been 22.0 ± 2 minutes (specimen imaging and 26.0 ± 3 minutes (neck imaging. Conclusion. Utilization of a novel real-time intraoperative LFOVGC imaging approach can provide confirmation of MIBI-avid parathyroid adenoma removal appreciably faster than IOPTH and/or path and may provide a valuable adjunct to parathyroid surgery.

  3. Down image recognition based on deep convolutional neural network

    Directory of Open Access Journals (Sweden)

    Wenzhu Yang

    2018-06-01

    Full Text Available Since of the scale and the various shapes of down in the image, it is difficult for traditional image recognition method to correctly recognize the type of down image and get the required recognition accuracy, even for the Traditional Convolutional Neural Network (TCNN. To deal with the above problems, a Deep Convolutional Neural Network (DCNN for down image classification is constructed, and a new weight initialization method is proposed. Firstly, the salient regions of a down image were cut from the image using the visual saliency model. Then, these salient regions of the image were used to train a sparse autoencoder and get a collection of convolutional filters, which accord with the statistical characteristics of dataset. At last, a DCNN with Inception module and its variants was constructed. To improve the recognition accuracy, the depth of the network is deepened. The experiment results indicate that the constructed DCNN increases the recognition accuracy by 2.7% compared to TCNN, when recognizing the down in the images. The convergence rate of the proposed DCNN with the new weight initialization method is improved by 25.5% compared to TCNN. Keywords: Deep convolutional neural network, Weight initialization, Sparse autoencoder, Visual saliency model, Image recognition

  4. Chaotic Image Scrambling Algorithm Based on S-DES

    International Nuclear Information System (INIS)

    Yu, X Y; Zhang, J; Ren, H E; Xu, G S; Luo, X Y

    2006-01-01

    With the security requirement improvement of the image on the network, some typical image encryption methods can't meet the demands of encryption, such as Arnold cat map and Hilbert transformation. S-DES system can encrypt the input binary flow of image, but the fixed system structure and few keys will still bring some risks. However, the sensitivity of initial value that Logistic chaotic map can be well applied to the system of S-DES, which makes S-DES have larger random and key quantities. A dual image encryption algorithm based on S-DES and Logistic map is proposed. Through Matlab simulation experiments, the key quantities will attain 10 17 and the encryption speed of one image doesn't exceed one second. Compared to traditional methods, it has some merits such as easy to understand, rapid encryption speed, large keys and sensitivity to initial value

  5. Integrated global digital image correlation for interface delamination characterization

    KAUST Repository

    Hoefnagels, Johan P.M.; Blaysat, Benoî t; Lubineau, Gilles; Geers, Marc G D

    2013-01-01

    , but require accurate interface models to capture (irreversible) crack initiation and propagation behavior observed in experiments. Therefore, an Integrated Global Digital Image Correlation (I-GDIC) strategy is developed for accurate determination of mechanical

  6. Prostate brachytherapy in Ghana: our initial experience

    Directory of Open Access Journals (Sweden)

    James Edward Mensah

    2016-10-01

    Full Text Available Purpose: This study presents the experience of a brachytherapy team in Ghana with a focus on technology transfer and outcome. The team was initially proctored by experienced physicians from Europe and South Africa. Material and methods : A total of 90 consecutive patients underwent either brachytherapy alone or brachytherapy in combination with external beam radiotherapy for prostate carcinoma between July 2008 and February 2014 at Korle Bu Teaching Hospital, Accra, Ghana. Patients were classified as low-risk, intermediate, and high-risk according to the National Comprehensive Cancer Network (NCCN criteria. All low-risk and some intermediate risk group patients were treated with seed implantation alone. Some intermediate and all high-risk group patients received brachytherapy combined with external beam radiotherapy. Results: The median patient age was 64.0 years (range 46-78 years. The median follow-up was 58 months (range 18-74 months. Twelve patients experienced biochemical failure including one patient who had evidence of metastatic disease and died of prostate cancer. Freedom from biochemical failure rates for low, intermediate, and high-risk cases were 95.4%, 90.9%, and 70.8%, respectively. Clinical parameters predictive of biochemical outcome included: clinical stage, Gleason score, and risk group. Pre-treatment prostate specific antigen (PSA was not a statistically significant predictor of biochemical failure. Sixty-nine patients (76.6% experienced grade 1 urinary symptoms in the form of frequency, urgency, and poor stream. These symptoms were mostly self-limiting. Four patients needed catheterization for urinary retention (grade 2. One patient developed a recto urethral fistula (grade 3 following banding for hemorrhoids. Conclusions : Our results compare favorably with those reported by other institutions with more extensive experience. We believe therefore that, interstitial permanent brachytherapy can be safely and effectively

  7. Initial Scaling Studies and Conceptual Thermal Fluids Experiments for the Prismatic NGNP Point Design

    Energy Technology Data Exchange (ETDEWEB)

    D. M. McEligot; G. E. McCreery

    2004-09-01

    The objective of this report is to document the initial high temperature gas reactor scaling studies and conceptual experiment design for gas flow and heat transfer. The general approach of the project is to develop new benchmark experiments for assessment in parallel with CFD and coupled CFD/ATHENA/RELAP5-3D calculations for the same geometry. Two aspects of the complex flow in an NGNP are being addressed: (1) flow and thermal mixing in the lower plenum ("hot streaking" issue) and (2) turbulence and resulting temperature distributions in reactor cooling channels ("hot channel" issue). Current prismatic NGNP concepts are being examined to identify their proposed flow conditions and geometries over the range from normal operation to decay heat removal in a pressurized cooldown. Approximate analyses are being applied to determine key non-dimensional parameters and their magnitudes over this operating range. For normal operation, the flow in the coolant channels can be considered to be dominant forced convection with slight transverse property variation. The flow in the lower plenum can locally be considered to be a situation of multiple buoyant jets into a confined density-stratified crossflow -- with obstructions. Experiments are needed for the combined features of the lower plenum flows. Missing from the typical jet experiments are interactions with nearby circular posts and with vertical posts in the vicinity of vertical walls - with near stagnant surroundings at one extreme and significant crossflow at the other. Two heat transfer experiments are being considered. One addresses the "hot channel" problem, if necessary. The second experiment will treat heated jets entering a model plenum. Unheated MIR (Matched-Index-of-Refraction) experiments are first steps when the geometry is complicated. One does not want to use a computational technique which will not even handle constant properties properly. The MIR experiment will simulate flow features of the paths of jets

  8. Radiological imaging of the neck for initial decision-making in oral squamous cell carcinomas-A questionnaire survey in the Nordic countries

    DEFF Research Database (Denmark)

    Norling, Rikke; Grau, Cai; Nielsen, Michael B

    2012-01-01

    by palpation and diagnostic imaging of the neck. We investigated the current practice of the initial radiological work-up of patients with oral squamous cell carcinomas (OSCC) in the Nordic countries. Methods. A questionnaire regarding the availability and use of guidelines and imaging modalities...

  9. Liver transplantations in Bulgaria--initial experience.

    Science.gov (United States)

    Vladov, N; Mihaylov, V; Takorov, I; Vasilevski, I; Lukanova, T; Odisseeva, E; Katzarov, K; Simonova, M; Tomova, D; Konakchieva, M; Petrov, N; Mladenov, N; Sergeev, S; Mutafchiiski, V

    2014-01-01

    The filed of liver transplantation (LT) continues to evolve and is highly effective therapy for many patients with acute and chronic liver failure resulting from a variety of causes. Improvement of perioperative care, surgical technique and immunosuppression in recent years has led to its transformation into a safe and routine procedure with steadily improving results. The aim of this paper is to present the initial experience of the transplant team at Military Medical Academy - Sofia, Bulgaria. For the period of April 2007 - August 2014 the team performed 38 liver transplants in 37 patients (one retransplantation). Patients were followed up prospectively and retrospectively. In 36 (95%) patients a graft from a cadaveric donor was used and in two cases--a right liver grafts from live donor. The mean MELD score of the transplanted patients was 17 (9-40). The preferred surgical technique was "piggyback" with preservation of inferior vena cava in 33 (86%) of the cases and classical technique in 3 (8%) patients. The overall complication rate was 48%. Early mortality rate was 13% (5 patients). The overall 1- and 5-year survival is 81% and 77% respectivelly. The setting of a new LT program is a complex process which requires the effort and effective colaboration of a wide range of speciacialists (hepatologists, surgeons, anesthesiologists, psychologists, therapists, coordinators, etc.) and institutions. The good results are function of a proper selection of the donors and the recipients. Living donation is an alternative in the shortage of cadaveric donors.

  10. Diffusion tensor imaging (DTI) and tractography of the brachial plexus: feasibility and initial experience in neoplastic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, Maria Isabel; Nguyen, Duy; Delavelle, Jacqueline [Geneva University Hospital, Department of Neuroradiology, DISIM, Geneve 14 (Switzerland); Viallon, Magalie [Geneva University Hospital and University of Geneva, Radiology, Geneva (Switzerland); Becker, Minerva [Geneva University Hospital and University of Geneva, Unit of Head and Neck Radiology, Geneva (Switzerland)

    2010-03-15

    The objective of this study was to assess the feasibility and potential clinical applications of diffusion tensor imaging (DTI) and tractography in the normal and pathologic brachial plexus prospectively. Six asymptomatic volunteers and 12 patients with symptoms related to the brachial plexus underwent DTI on a 1.5T system in addition to the routine anatomic plexus imaging protocol. Maps of the apparent diffusion coefficient (ADC) and of fractional anisotropy (FA), as well as tractography of the brachial plexus were obtained. Images were evaluated by two experienced neuroradiologists in a prospective fashion. Three patients underwent surgery, and nine patients underwent conservative medical treatment. Reconstructed DTI (17/18) were of good quality (one case could not be reconstructed due to artifacts). In all volunteers and in 11 patients, the roots and the trunks were clearly delineated with tractography. Mean FA and mean ADC values were as follows: 0.30{+-}0.079 and 1.70{+-}0.35 mm{sup 2}/s in normal fibers, 0.22{+-}0.04 and 1.49{+-}0.49 mm{sup 2}/s in benign neurogenic tumors, and 0.24{+-}0.08 and 1.51{+-}0.52 mm{sup 2}/s in malignant tumors, respectively. Although there was no statistically significant difference in FA and ADC values of normal fibers and fibers at the level of pathology, tractography revealed major differences regarding fiber architecture. In benign neurogenic tumors (n=4), tractography revealed fiber displacement alone (n=2) or fiber displacement and encasement by the tumor (n=2), whereas in the malignant tumors, either fiber disruption/destruction with complete disorganization (n=6) or fiber displacement (n=1) were seen. In patients with fiber displacement alone, surgery confirmed the tractography findings, and excision was successful without sequelae. Our preliminary data suggest that DTI with tractography is feasible in a clinical routine setting. DTI may demonstrate normal tracts, tract displacement, deformation, infiltration, disruption

  11. Diffusion tensor imaging (DTI) and tractography of the brachial plexus: feasibility and initial experience in neoplastic conditions

    International Nuclear Information System (INIS)

    Vargas, Maria Isabel; Nguyen, Duy; Delavelle, Jacqueline; Viallon, Magalie; Becker, Minerva

    2010-01-01

    The objective of this study was to assess the feasibility and potential clinical applications of diffusion tensor imaging (DTI) and tractography in the normal and pathologic brachial plexus prospectively. Six asymptomatic volunteers and 12 patients with symptoms related to the brachial plexus underwent DTI on a 1.5T system in addition to the routine anatomic plexus imaging protocol. Maps of the apparent diffusion coefficient (ADC) and of fractional anisotropy (FA), as well as tractography of the brachial plexus were obtained. Images were evaluated by two experienced neuroradiologists in a prospective fashion. Three patients underwent surgery, and nine patients underwent conservative medical treatment. Reconstructed DTI (17/18) were of good quality (one case could not be reconstructed due to artifacts). In all volunteers and in 11 patients, the roots and the trunks were clearly delineated with tractography. Mean FA and mean ADC values were as follows: 0.30±0.079 and 1.70±0.35 mm 2 /s in normal fibers, 0.22±0.04 and 1.49±0.49 mm 2 /s in benign neurogenic tumors, and 0.24±0.08 and 1.51±0.52 mm 2 /s in malignant tumors, respectively. Although there was no statistically significant difference in FA and ADC values of normal fibers and fibers at the level of pathology, tractography revealed major differences regarding fiber architecture. In benign neurogenic tumors (n=4), tractography revealed fiber displacement alone (n=2) or fiber displacement and encasement by the tumor (n=2), whereas in the malignant tumors, either fiber disruption/destruction with complete disorganization (n=6) or fiber displacement (n=1) were seen. In patients with fiber displacement alone, surgery confirmed the tractography findings, and excision was successful without sequelae. Our preliminary data suggest that DTI with tractography is feasible in a clinical routine setting. DTI may demonstrate normal tracts, tract displacement, deformation, infiltration, disruption, and disorganization of

  12. Live-cell imaging of conidial anastomosis tube fusion during colony initiation in Fusarium oxysporum.

    Directory of Open Access Journals (Sweden)

    Smija M Kurian

    Full Text Available Fusarium oxysporum exhibits conidial anastomosis tube (CAT fusion during colony initiation to form networks of conidial germlings. Here we determined the optimal culture conditions for this fungus to undergo CAT fusion between microconidia in liquid medium. Extensive high resolution, confocal live-cell imaging was performed to characterise the different stages of CAT fusion, using genetically encoded fluorescent labelling and vital fluorescent organelle stains. CAT homing and fusion were found to be dependent on adhesion to the surface, in contrast to germ tube development which occurs in the absence of adhesion. Staining with fluorescently labelled concanavalin A indicated that the cell wall composition of CATs differs from that of microconidia and germ tubes. The movement of nuclei, mitochondria, vacuoles and lipid droplets through fused germlings was observed by live-cell imaging.

  13. Radiation therapists' perceptions of the minimum level of experience required to perform portal image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Rybovic, Michala [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825 (Australia)], E-mail: mryb6983@mail.usyd.edu.au; Halkett, Georgia K. [Western Australia Centre for Cancer and Palliative Care, Curtin University of Technology, Health Research Campus, GPO Box U1987, Perth, WA 6845 (Australia)], E-mail: g.halkett@curtin.edu.au; Banati, Richard B. [Faculty of Health Sciences, Brain and Mind Research Institute - Ramaciotti Centre for Brain Imaging, University of Sydney, PO Box 170, Lidcombe, NSW 1825 (Australia)], E-mail: r.banati@usyd.edu.au; Cox, Jennifer [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825 (Australia)], E-mail: jenny.cox@usyd.edu.au

    2008-11-15

    Background and purpose: Our aim was to explore radiation therapists' views on the level of experience necessary to undertake portal image analysis and clinical decision making. Materials and methods: A questionnaire was developed to determine the availability of portal imaging equipment in Australia and New Zealand. We analysed radiation therapists' responses to a specific question regarding their opinion on the minimum level of experience required for health professionals to analyse portal images. We used grounded theory and a constant comparative method of data analysis to derive the main themes. Results: Forty-six radiation oncology facilities were represented in our survey, with 40 questionnaires being returned (87%). Thirty-seven radiation therapists answered our free-text question. Radiation therapists indicated three main themes which they felt were important in determining the minimum level of experience: 'gaining on-the-job experience', 'receiving training' and 'working as a team'. Conclusions: Radiation therapists indicated that competence in portal image review occurs via various learning mechanisms. Further research is warranted to determine perspectives of other health professionals, such as radiation oncologists, on portal image review becoming part of radiation therapists' extended role. Suitable training programs and steps for implementation should be developed to facilitate this endeavour.

  14. Application of an Image Tracking Algorithm in Fire Ant Motion Experiment

    Directory of Open Access Journals (Sweden)

    Lichuan Gui

    2009-04-01

    Full Text Available An image tracking algorithm, which was originally used with the particle image velocimetry (PIV to determine velocities of buoyant solid particles in water, is modified and applied in the presented work to detect motion of fire ant on a planar surface. A group of fire ant workers are put to the bottom of a tub and excited with vibration of selected frequency and intensity. The moving fire ants are captured with an image system that successively acquires image frames of high digital resolution. The background noise in the imaging recordings is extracted by averaging hundreds of frames and removed from each frame. The individual fire ant images are identified with a recursive digital filter, and then they are tracked between frames according to the size, brightness, shape, and orientation angle of the ant image. The speed of an individual ant is determined with the displacement of its images and the time interval between frames. The trail of the individual fire ant is determined with the image tracking results, and a statistical analysis is conducted for all the fire ants in the group. The purpose of the experiment is to investigate the response of fire ants to the substrate vibration. Test results indicate that the fire ants move faster after being excited, but the number of active ones are not increased even after a strong excitation.

  15. Sociocultural experiences, body image, and indoor tanning among young adult women.

    Science.gov (United States)

    Stapleton, Jerod L; Manne, Sharon L; Greene, Kathryn; Darabos, Katie; Carpenter, Amanda; Hudson, Shawna V; Coups, Elliot J

    2017-10-01

    The purpose of this survey study was to evaluate a model of body image influences on indoor tanning behavior. Participants were 823 young adult women recruited from a probability-based web panel in the United States. Consistent with our hypothesized model, tanning-related sociocultural experiences were indirectly associated with lifetime indoor tanning use and intentions to tan as mediated through tan surveillance and tan dissatisfaction. Findings suggest the need for targeting body image constructs as mechanisms of behavior change in indoor tanning behavioral interventions.

  16. Initial clinical experiences with dopamine D2 receptor imaging by means of 2'-iodospiperone and single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Saji, Hideo; Iwasaki, Yasushi

    1995-01-01

    Dopamine D 2 receptor imaging was performed with 123 I labeled 2'-iodospiperone (2'-ISP) and single-photon emission computed tomography (SPECT) in 9 patients: 4 with idiopathic Parkinson's disease, 2 with parkinsonism, 1 with Wilson's disease and 2 with pituitary tumor, and the results were compared with the data for 9 normal subjects. Following an intravenous injection of 123 I-2'-ISP, early (within 30 min) and late (between 2 and 4 hr) SPECT images were obtained by means of a multi-detector SPECT scanner or a rotating gamma camera. In normal subjects, early SPECT images demonstrated uniform distribution of radioactivity in the cerebral gray matter and cerebellum reflecting regional cerebral blood flow, whereas late SPECT images showed high radioactivity only in the basal ganglia. All the patients with Parkinson's disease also demonstrated symmetrical basal ganglia uptake in the late SPECT images, but it was diminished in parkinsonism and Wilson's disease. One patient with a growth hormone-producing pituitary tumor had a positive uptake in the tumor. These preliminary clinical data demonstrated that 2'-ISP can be used for SPECT imaging of D 2 dopamine receptors and may be of clinical value for the diagnosis and planning of the treatment of neurological diseases. (author)

  17. Thermophysical Property Estimation by Transient Experiments: The Effect of a Biased Initial Temperature Distribution

    Directory of Open Access Journals (Sweden)

    Federico Scarpa

    2015-01-01

    Full Text Available The identification of thermophysical properties of materials in dynamic experiments can be conveniently performed by the inverse solution of the associated heat conduction problem (IHCP. The inverse technique demands the knowledge of the initial temperature distribution within the material. As only a limited number of temperature sensors (or no sensor at all are arranged inside the test specimen, the knowledge of the initial temperature distribution is affected by some uncertainty. This uncertainty, together with other possible sources of bias in the experimental procedure, will propagate in the estimation process and the accuracy of the reconstructed thermophysical property values could deteriorate. In this work the effect on the estimated thermophysical properties due to errors in the initial temperature distribution is investigated along with a practical method to quantify this effect. Furthermore, a technique for compensating this kind of bias is proposed. The method consists in including the initial temperature distribution among the unknown functions to be estimated. In this way the effect of the initial bias is removed and the accuracy of the identified thermophysical property values is highly improved.

  18. Magnetic resonance imaging - guided vacuum-assisted breast biopsy: an initial experience in a community hospital

    International Nuclear Information System (INIS)

    Friedman, P.; Enis, S.; Pinyard, J.

    2009-01-01

    To evaluate the effectiveness in diagnosing mammographically and sonographically occult breast lesions by using magnetic resonance imaging (MRI) guided vacuum-assisted breast biopsy in patients who presented to a community-based hospital with a newly established breast MRI program. The records of 142 consecutive patients, median age of 55 years, who had undergone MRI-guided biopsy at our institution between July 2006 and July 2007 were reviewed. From these patients, 197 mammographically and sonographically occult lesions were biopsied at the time of discovery. The pathology was then reviewed and correlated with the MRI findings. Cancer was present and subsequently discovered in 8% of the previously occult lesions (16/197) or 11% of the women studied (16/142). Of the cancerous lesions, 56% were invasive carcinomas (9/16) and 44% were ductal carcinomas in situ (7/16). Fourteen percent of the discovered lesions (28/197) were defined as high risk and included atypical ductal hyperplasia, atypical lobular hyperplasia, lobular carcinoma in situ, and radial scar. In total, occult cancerous and high-risk lesions were discovered in 22% of the found lesions (44/197) or 31% of the women who underwent MRI-guided biopsy (44/142). This study demonstrated that detection of cancerous and high-risk lesions can be significantly increased when an MRI-guided biopsy program is introduced at a community-based hospital. We believe that as radiologists gain confidence in imaging and histologic correlation, community-based hospitals can achieve similar rates of occult lesion diagnosis as those found in data emerging from academic institutions. (author)

  19. Magnetic resonance imaging - guided vacuum-assisted breast biopsy: an initial experience in a community hospital

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, P.; Enis, S.; Pinyard, J., E-mail: jpinyard@gmail.com [Morristown Memorial Hospital, The Carol W. and Julius A. Rippel Breast Center, The Carol G. Simon Cancer Centre, Morristown, New Jersey (United States)

    2009-10-15

    To evaluate the effectiveness in diagnosing mammographically and sonographically occult breast lesions by using magnetic resonance imaging (MRI) guided vacuum-assisted breast biopsy in patients who presented to a community-based hospital with a newly established breast MRI program. The records of 142 consecutive patients, median age of 55 years, who had undergone MRI-guided biopsy at our institution between July 2006 and July 2007 were reviewed. From these patients, 197 mammographically and sonographically occult lesions were biopsied at the time of discovery. The pathology was then reviewed and correlated with the MRI findings. Cancer was present and subsequently discovered in 8% of the previously occult lesions (16/197) or 11% of the women studied (16/142). Of the cancerous lesions, 56% were invasive carcinomas (9/16) and 44% were ductal carcinomas in situ (7/16). Fourteen percent of the discovered lesions (28/197) were defined as high risk and included atypical ductal hyperplasia, atypical lobular hyperplasia, lobular carcinoma in situ, and radial scar. In total, occult cancerous and high-risk lesions were discovered in 22% of the found lesions (44/197) or 31% of the women who underwent MRI-guided biopsy (44/142). This study demonstrated that detection of cancerous and high-risk lesions can be significantly increased when an MRI-guided biopsy program is introduced at a community-based hospital. We believe that as radiologists gain confidence in imaging and histologic correlation, community-based hospitals can achieve similar rates of occult lesion diagnosis as those found in data emerging from academic institutions. (author)

  20. Initial Experience with a Handheld Device Digital Imaging and Communications in Medicine Viewer: OsiriX Mobile on the iPhone

    OpenAIRE

    Choudhri, Asim F.; Radvany, Martin G.

    2010-01-01

    Medical imaging is commonly used to diagnose many emergent conditions, as well as plan treatment. Digital images can be reviewed on almost any computing platform. Modern mobile phones and handheld devices are portable computing platforms with robust software programming interfaces, powerful processors, and high-resolution displays. OsiriX mobile, a new Digital Imaging and Communications in Medicine viewing program, is available for the iPhone/iPod touch platform. This raises the possibility o...

  1. The CORONAS-Photon/TESIS experiment on EUV imaging spectroscopy of the Sun

    Science.gov (United States)

    Kuzin, S.; Zhitnik, I.; Bogachev, S.; Bugaenko, O.; Ignat'ev, A.; Mitrofanov, A.; Perzov, A.; Shestov, S.; Slemzin, V.; Suhodrev, N.

    The new experiment TESIS is developent for russian CORONAS-Photon mission launch is planned on the end of 2007 The experiment is aimed on the study of activity of the Sun in the phases of minimum rise and maximum of 24 th cycle of Solar activity by the method of XUV imaging spectroscopy The method is based on the registration full-Sun monochromatic images with high spatial and temporal resolution The scientific tasks of the experiment are i Investigation dynamic processes in corona flares CME etc with high spatial up to 1 and temporal up to 1 second resolution ii determination of the main plasma parameters like plasma electron and ion density and temperature differential emission measure etc iii study of the processes of appearance and development large scale long-life magnetic structures in the solar corona study of the fluency of this structures on the global activity of the corona iv study of the mechanisms of energy accumulation and release in the solar flares and mechanisms of transformation of this energy into the heating of the plasma and kinematics energy To get the information for this studies the TESIS will register full-Sun images in narrow spectral intervals and the monochromatic lines of HeII SiXI FeXXI-FeXXIII MgXII ions The instrument includes 5 independent channels 2 telescopes for 304 and 132 A wide-field 2 5 degrees coronograph 280-330A and 8 42 A spectroheliographs The detailed description of the TESIS experiment and the instrument is presented

  2. Three-dimensional image reconstruction using rotational digital subtraction technique: the initial experience of the clinical application

    International Nuclear Information System (INIS)

    Ouyang Zhongnan; Tang Jun; He Jianjun; Lu Xiaohe; Xun Yanping

    2002-01-01

    Objective: To evaluate the benefit of three-dimensional (3D) reconstruction images with rotational digital subtraction technique for the clinical applications. Methods: Conventional two-dimensional digital substraction angiography (2D DSA) was obtained on A-P and lateral view. Three-dimensional digital subtraction angiography (3D DSA) images were obtained by reconstruction of a rotational acquisition on a C-arm (LCV +, GE Medical Systems) spinning at 40 degrees per second. 53 cases of cerebral angiographies were performed (32 men and 21 women; the age ranged from 19 to 72 years, mean 46.3 years). Results: In this series of 53 cases of cerebral angiographies, 5 cases of arteriovenous malformation were all correctly diagnosed by 3D DSA and 2D DSA. Seven cases were misdiagnosed as intracranial aneurysms at conventional 2D DSA but confirmed to be kinking of the vessel by 3D DSA. 41 cases were confirmed to be intracranial aneurysms. Of the 41 cases, 5 cases were diagnosed as normal at 2D DSA but confirmed to be intracranial aneurysms at 3D DSA. The total consistency rate of 3D DSA and 2D DSA for the diagnosis of intracranial aneurysm is 77.4% (41/53). The consistent test shows that there was consistency between the two modalities (chi-square test, χ 2 = 5.267, P < 0.05). 29 cases were treated with endovascular coil embolization. Among them only 3 cases of the aneurysm's neck could be best visualized by 2D DSA but 29 cases by 3D DSA. Conclusion: 3D reconstruction images with rotational digital subtraction technique is a useful tool to study the vascular diseases using less contrast agent and a lower radiation dose and shortening the examination process. It is replenishment for conventional 2D DSA. This technique enables better diagnosis for intracranial vascular lesion and visualization of complex vascular relationships and structures. It is valuable for surgical planning and interventional procedure

  3. Comparison of initial and delayed myocardial imaging with beta-methyl-p-[[sup 123]I]-iodophenylpentadecanoic acid in acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Naruse, Hitoshi; Yoshimura, Noriko; Yamamoto, Juro; Morita, Masato; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru (Hyogo Coll. of Medicine, Nishinomiya (Japan))

    Myocardial imaging using [beta]-methyl-p-[[sup 123]I]-iodophenylpentadecanoic acid (BMIPP) of 15 patients with acute myocardial infarction was performed to assess 'fill-in' and 'washout' defects in the delayed myocardial image. The initial and delayed images were evaluated by a visual and quantitative washout rate method. Visual judgement found 8/180 (4%) segments showed 'fill-in' defects, and 24/180 segments (13%) showed 'washout' defects. There was no relationship between days from onset to the study and the frequency of fill-in and washout defects. The mean washout rate in the segments with 'fill-in' defects was 9.0[+-]16.6%, and that of 'washout' defects was 24.9[+-]18.1% which was significantly higher than in controls (8.7[+-]15.4%, p<0.05). There was no correlation between mean washout rate and total blood lipids, total cholesterol, triglyceride and HDL-cholesterol. Therefore, neither time from onset nor blood lipids level was related to changes from the initial image to the delayed image. These changes may be due to relative (false) findings due to changes in circumference, and may be based on myocardial characteristics after myocardial infarction and/or reperfusion. (author).

  4. Comparison of initial and tertiary centre second opinion reads of multiparametric magnetic resonance imaging of the prostate prior to repeat biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Nienke L. [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology, Aachen (Germany); Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Koo, Brendan C.; Gallagher, Ferdia A. [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Warren, Anne Y. [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital, Department of Pathology, Cambridge (United Kingdom); Doble, Andrew; Gnanapragasam, Vincent; Bratt, Ola; Kastner, Christof [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital, Department of Urology, Cambridge (United Kingdom); Barrett, Tristan [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); University of Cambridge School of Clinical Medicine, Department of Radiology, Box 218, Cambridge (United Kingdom)

    2017-06-15

    To investigate the value of second-opinion evaluation of multiparametric prostate magnetic resonance imaging (MRI) by subspecialised uroradiologists at a tertiary centre for the detection of significant cancer in transperineal fusion prostate biopsy. Evaluation of prospectively acquired initial and second-opinion radiology reports of 158 patients who underwent MRI at regional hospitals prior to transperineal MR/untrasound fusion biopsy at a tertiary referral centre over a 3-year period. Gleason score (GS) 7-10 cancer, positive predictive value (PPV) and negative (NPV) predictive value (±95 % confidence intervals) were calculated and compared by Fisher's exact test. Disagreement between initial and tertiary centre second-opinion reports was observed in 54 % of cases (86/158). MRIs had a higher NPV for GS 7-10 in tertiary centre reads compared to initial reports (0.89 ± 0.08 vs 0.72 ± 0.16; p = 0.04), and a higher PPV in the target area for all cancer (0.61 ± 0.12 vs 0.28 ± 0.10; p = 0.01) and GS 7-10 cancer (0.43 ± 0.12 vs 0.2 3 ± 0.09; p = 0.02). For equivocal suspicion, the PPV for GS 7-10 was 0.12 ± 0.11 for tertiary centre and 0.11 ± 0.09 for initial reads; p = 1.00. Second readings of prostate MRI by subspecialised uroradiologists at a tertiary centre significantly improved both NPV and PPV. Reporter experience may help to reduce overcalling and avoid overtargeting of lesions. (orig.)

  5. Enhancements to the Image Analysis Tool for Core Punch Experiments and Simulations (vs. 2014)

    Energy Technology Data Exchange (ETDEWEB)

    Hogden, John Edward [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Unal, Cetin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-06

    A previous paper (Hogden & Unal, 2012, Image Analysis Tool for Core Punch Experiments and Simulations) described an image processing computer program developed at Los Alamos National Laboratory. This program has proven useful so developement has been continued. In this paper we describe enhacements to the program as of 2014.

  6. Clinical Experiences With Onboard Imager KV Images for Linear Accelerator-Based Stereotactic Radiosurgery and Radiotherapy Setup

    International Nuclear Information System (INIS)

    Hong, Linda X.; Chen, Chin C.; Garg, Madhur; Yaparpalvi, Ravindra; Mah, Dennis

    2009-01-01

    Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly basis for 6 SRT patients to assess any intrafraction changes. Results: For SRS patients, 57 pretreatment kV images were evaluated and the suggested shifts were all within 1 mm in any direction (i.e., within the accuracy of image fusion). For SRT patients, the suggested shifts were out of the 3-mm tolerance for 31 of 309 setups. Intrafraction motions were detected in 3 SRT patients. Conclusions: kV imaging provided a useful tool for SRS or SRT setups. For SRS setup with head frame, it provides radiographic confirmation of localization using the stereotactic target positioner. For SRT with mask, a 3-mm margin is adequate and feasible for routine setup when TaPo is combined with kV imaging

  7. Initial experiences in the photoacoustic detection of melanoma metastases in resected lymph nodes

    Science.gov (United States)

    Grootendorst, D.; Jose, J.; Van der Jagt, P.; Van der Weg, W.; Nagel, K.; Wouters, M.; Van Boven, H.; Van Leeuwen, T. G.; Steenbergen, W.; Ruers, T.; Manohar, S.

    2011-03-01

    Accurate lymph node analysis is essential to determine the prognosis and treatment of patients suffering from melanoma. The initial results of a tomographic photoacoustic modality to detect melanoma metastases in resected lymph nodes are presented based on phantom models and a human lymph node. The results show melanoma metastases detection is feasible and the setup is capable of distinguishing absorbing structures down to 1 mm. In addition, the use of longer laser wavelengths could result in an image containing a higher contrast ratio. Future research shall be focused on using the melanin characteristics to improve contrast and detection possibilities.

  8. Collaborative Initiative in Biomedical Imaging to Study Complex Diseases

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Weili [The University of North Carolina at Chapel Hill; Fiddy, Michael A. [The University of North Carolina at Charlotte

    2012-03-31

    The work reported addressed these topics: Fluorescence imaging; Optical coherence tomography; X-ray interferometer/phase imaging system; Quantitative imaging from scattered fields, Terahertz imaging and spectroscopy; and Multiphoton and Raman microscopy.

  9. Body image and sexual orientation: The experiences of lesbian and bisexual women.

    Science.gov (United States)

    Smith, Marie L; Telford, Elina; Tree, Jeremy J

    2017-02-01

    Western cultures promote a thin and curvaceous ideal body size that most women find difficult to achieve by healthy measures, resulting in poor body image and increased risk for eating pathology. Research focusing on body image in lesbian and bisexual women has yielded inconsistent results. In total, 11 lesbian and bisexual women were interviewed regarding their experiences with body image. Interpretative phenomenological analysis revealed that these women experienced similar mainstream pressures to conform to a thin body ideal. Furthermore, participants perceived additional pressure to conform to heteronormative standards of beauty since the normalisation of homosexuality and the increase in Lesbian, Gay, Bisexual and Transgender representation in mainstream media.

  10. [Development of RF coil of permanent magnet mini-magnetic resonance imager and mouse imaging experiments].

    Science.gov (United States)

    Hou, Shulian; Xie, Huantong; Chen, Wei; Wang, Guangxin; Zhao, Qiang; Li, Shiyu

    2014-10-01

    In the development of radio frequency (RF) coils for better quality of the mini-type permanent magnetic resonance imager for using in the small animal imaging, the solenoid RF coil has a special advantage for permanent magnetic system based on analyses of various types.of RF coils. However, it is not satisfied for imaging if the RF coils are directly used. By theoretical analyses of the magnetic field properties produced from the solenoid coil, the research direction was determined by careful studies to raise further the uniformity of the magnetic field coil, receiving coil sensitivity for signals and signal-to-noise ratio (SNR). The method had certain advantages and avoided some shortcomings of the other different coil types, such as, birdcage coil, saddle shaped coil and phased array coil by using the alloy materials (from our own patent). The RF coils were designed, developed and made for keeled applicable to permanent magnet-type magnetic resonance imager, multi-coil combination-type, single-channel overall RF receiving coil, and applied for a patent. Mounted on three instruments (25 mm aperture, with main magnetic field strength of 0.5 T or 1.5 T, and 50 mm aperture, with main magnetic field strength of 0.48 T), we performed experiments with mice, rats, and nude mice bearing tumors. The experimental results indicated that the RF receiving coil was fully applicable to the permanent magnet-type imaging system.

  11. Small angle X-ray scattering experiments with three-dimensional imaging gas detectors

    International Nuclear Information System (INIS)

    La Monaca, A.; Iannuzzi, M.; Messi, R.

    1985-01-01

    Measurements of small angle X-ray scattering of lupolen - R, dry collagen and dry cornea are presented. The experiments have been performed with synchrotron radiation and a new three-dimensional imaging drif-chamber gas detector

  12. Initial Experiences of Simultaneous Laparoscopic Resection of Colorectal Cancer and Liver Metastases

    Directory of Open Access Journals (Sweden)

    L. T. Hoekstra

    2012-01-01

    Full Text Available Introduction. Simultaneous resection of primary colorectal carcinoma (CRC and synchronous liver metastases (SLMs is subject of debate with respect to morbidity in comparison to staged resection. The aim of this study was to evaluate our initial experience with this approach. Methods. Five patients with primary CRC and a clinical diagnosis of SLM underwent combined laparoscopic colorectal and liver surgery. Patient and tumor characteristics, operative variables, and postoperative outcomes were evaluated retrospectively. Results. The primary tumor was located in the colon in two patients and in the rectum in three patients. The SLM was solitary in four patients and multiple in the remaining patient. Surgical approach was total laparoscopic (2 patients or hand-assisted laparoscopic (3 patients. The midline umbilical or transverse suprapubic incision created for the hand port and/or extraction of the specimen varied between 5 and 10 cm. Median operation time was 303 (range 151–384 minutes with a total blood loss of 700 (range 200–850 mL. Postoperative hospital stay was 5, 5, 9, 14, and 30 days. An R0 resection was achieved in all patients. Conclusions. From this initial single-center experience, simultaneous laparoscopic colorectal and liver resection appears to be feasible in selected patients with CRC and SLM, with satisfying short-term results.

  13. Preparing beginning reading teachers: An experimental comparison of initial early literacy field experiences

    OpenAIRE

    Al Otaiba, Stephanie; Lake, Vickie E.; Greulich, Luana; Folsom, Jessica S.; Guidry, Lisa

    2012-01-01

    This randomized-control trial examined the learning of preservice teachers taking an initial Early Literacy course in an early childhood education program and of the kindergarten or first grade students they tutored in their field experience. Preservice teachers were randomly assigned to one of two tutoring programs: Book Buddies and Tutor Assisted Intensive Learning Strategies (TAILS), which provided identical meaning-focused instruction (shared book reading), but differed ...

  14. Diffusion-weighted MR imaging of kidneys in patients with chronic kidney disease: initial study

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xueqin; Fang, Wenqiang; Ling, Huawei; Chai, Weimin; Chen, Kemin [Ruijin Hospital Shanghai, Jiaotong University School of Medicine, Department of Radiology, Shanghai (China)

    2010-04-15

    To prospectively evaluate the feasibility of diffusion-weighted (DW) magnetic resonance (MR) imaging in the assessment of renal function in patients with chronic kidney disease (CKD). Seventy-two healthy volunteers and 43 patients underwent coronal echo-planar DW MR imaging of the kidneys with a single breath-hold time of 16 s. The patients were grouped according to five stages as indicated by the K/DOQI CKD (kidney disease outcome quality initiative). The apparent diffusion coefficient (ADC) value of the kidneys was calculated with high b values (b = 500 s/mm{sup 2}). The ADC values were compared between patients and healthy volunteers, and among different stages. For statistical analysis, Student's t tests, ANOVA, Pearson's correlation tests, and Spearman's correlation tests were used. No difference between the cortex and medulla could be observed on DW images of all volunteers. Patients with CKD had significantly lower renal ADC (t = -4.383, P = 0.000) than volunteers. The ADC values of kidneys were significantly lower than normal at most stages of CKD, except CKD1. There was a negative correlation between the ADCs and serum creatinine (sCr) level (P = 0.000) amongst the patients. Diffusion-weighted MR imaging is feasible in the assessment of renal function, especially in the detection of early stage renal failure of CKD. (orig.)

  15. Diffusion-weighted MR imaging of kidneys in patients with chronic kidney disease: initial study

    International Nuclear Information System (INIS)

    Xu, Xueqin; Fang, Wenqiang; Ling, Huawei; Chai, Weimin; Chen, Kemin

    2010-01-01

    To prospectively evaluate the feasibility of diffusion-weighted (DW) magnetic resonance (MR) imaging in the assessment of renal function in patients with chronic kidney disease (CKD). Seventy-two healthy volunteers and 43 patients underwent coronal echo-planar DW MR imaging of the kidneys with a single breath-hold time of 16 s. The patients were grouped according to five stages as indicated by the K/DOQI CKD (kidney disease outcome quality initiative). The apparent diffusion coefficient (ADC) value of the kidneys was calculated with high b values (b = 500 s/mm 2 ). The ADC values were compared between patients and healthy volunteers, and among different stages. For statistical analysis, Student's t tests, ANOVA, Pearson's correlation tests, and Spearman's correlation tests were used. No difference between the cortex and medulla could be observed on DW images of all volunteers. Patients with CKD had significantly lower renal ADC (t = -4.383, P = 0.000) than volunteers. The ADC values of kidneys were significantly lower than normal at most stages of CKD, except CKD1. There was a negative correlation between the ADCs and serum creatinine (sCr) level (P = 0.000) amongst the patients. Diffusion-weighted MR imaging is feasible in the assessment of renal function, especially in the detection of early stage renal failure of CKD. (orig.)

  16. Intravoxel incoherent motion diffusion-weighted imaging in stroke patients: initial clinical experience

    International Nuclear Information System (INIS)

    Yao, Y.; Zhang, S.; Tang, X.; Zhang, S.; Shi, J.; Zhu, W.; Zhu, W.

    2016-01-01

    Aim: To evaluate the feasibility of using intravoxel incoherent motion (IVIM) to measure diffusion and perfusion parameter variations in stroke. Materials and methods: Thirty-eight stroke patients were enrolled in the study. IVIM imaging was performed using 15 b-values from 0 to 1000 s/mm"2. Arterial spin labelling (ASL) magnetic resonance perfusion was also undertaken. Relations between the IVIM parameters (including apparent diffusion coefficient [ADC], diffusion coefficient D_s_l_o_w [D], pseudo-diffusion coefficient D_f_a_s_t [D*], fractional perfusion-related volume [f]) and fD* (the multiplication of the first two parameters) and the ASL-derived parameter, cerebral blood flow (CBF), were analysed using paired t-tests. Comparisons of all the parameters between lesions and contralateral normal regions, as well as between acute and subacute groups were analysed using Student's t-test. Results: There were positive correlations between f and CBF as well as fD* and CBF (r=0.472 and 0.653). Quantitative analysis showed a significant decrease in ADC, D, D*, f, fD*, and CBF of the lesions compared with the contralateral side, in which the decrease of fD* (68.6%) was highest. The values of ADC, f, and fD* increased in the subacute period group compared with the acute period group. Conclusions: IVIM analysis allowed separation of perfusion contribution from true diffusion and thus provided an evaluation of the perfusion and diffusion variations during stroke, which might further elucidate the mechanisms of ischaemic stroke. - Highlights: • There exist positive correlations between fractional perfusion-related volume (f) and cerebral blood flow (CBF) as well as fD"∗ and CBF. • A significant decrease in ADC, diffusion coefficient D_s_l_o_w (D), pseudo-diffusion coefficient D_f_a_s_t (D"∗), f, fD"∗ and CBF of the lesions compared with the contralateral normal regions. • The values of ADC, f and fD"∗ increase significantly in the subacute period compared with

  17. VQone MATLAB toolbox: A graphical experiment builder for image and video quality evaluations: VQone MATLAB toolbox.

    Science.gov (United States)

    Nuutinen, Mikko; Virtanen, Toni; Rummukainen, Olli; Häkkinen, Jukka

    2016-03-01

    This article presents VQone, a graphical experiment builder, written as a MATLAB toolbox, developed for image and video quality ratings. VQone contains the main elements needed for the subjective image and video quality rating process. This includes building and conducting experiments and data analysis. All functions can be controlled through graphical user interfaces. The experiment builder includes many standardized image and video quality rating methods. Moreover, it enables the creation of new methods or modified versions from standard methods. VQone is distributed free of charge under the terms of the GNU general public license and allows code modifications to be made so that the program's functions can be adjusted according to a user's requirements. VQone is available for download from the project page (http://www.helsinki.fi/psychology/groups/visualcognition/).

  18. Flash trajectory imaging of target 3D motion

    Science.gov (United States)

    Wang, Xinwei; Zhou, Yan; Fan, Songtao; He, Jun; Liu, Yuliang

    2011-03-01

    We present a flash trajectory imaging technique which can directly obtain target trajectory and realize non-contact measurement of motion parameters by range-gated imaging and time delay integration. Range-gated imaging gives the range of targets and realizes silhouette detection which can directly extract targets from complex background and decrease the complexity of moving target image processing. Time delay integration increases information of one single frame of image so that one can directly gain the moving trajectory. In this paper, we have studied the algorithm about flash trajectory imaging and performed initial experiments which successfully obtained the trajectory of a falling badminton. Our research demonstrates that flash trajectory imaging is an effective approach to imaging target trajectory and can give motion parameters of moving targets.

  19. "My body was my temple": a narrative revealing body image experiences following treatment of a spinal cord injury.

    Science.gov (United States)

    Bailey, K Alysse; Gammage, Kimberley L; van Ingen, Cathy; Ditor, David S

    2017-09-01

    This narrative explores the lived experience of a young woman, Rebecca, and her transitioned body image after sustaining and being treated for a spinal cord injury. Data were collected from a single semi-structured in-depth interview. Rebecca disclosed her transitioned body image experiences after sustaining a spinal cord injury and being treated by medical staff immediately following her injury. Before her injury, she described a holistic body experience and named this experience her "temple". During intensive care in the hospital, she explained her body was treated as an object. The disconnected treatment of her body led to a loss of the private self, as she described her sacred body being stripped away - her "temple" lost and in ruins. Body image may be an overlooked component of health following a spinal cord injury. This narrative emphasizes the importance of unveiling body image experiences after the treatment of a spinal cord injury to medical professionals. Lessons of the importance of considering the transitioned body experiences after a spinal cord injury may help prevent body-related depression and other subsequent health impacts. Recommendations for best practice are provided. Implications for Rehabilitation    Spinal Cord Injury   • A spinal cord injury may drastically change a person's body image, thereby significantly impacting psychological health   • More effective screening for body image within the medical/rehabilitation context is needed to help practitioners recognize distress   • Practitioners should be prepared to refer clients to distress hotlines they may need once released from treatment.

  20. Medical student perceptions of an initial collaborative immersion experience.

    Science.gov (United States)

    House, Joseph B; Cedarbaum, Jacob; Haque, Fatema; Wheaton, Michael; Vredeveld, Jennifer; Purkiss, Joel; Moore, Laurel; Santen, Sally A; Daniel, Michelle

    2018-03-01

    Recent reviews of interprofessional education (IPE) highlight the need for innovative curricula focused on longitudinal clinical learning. We describe the development and early outcomes of the initial clinical experience (ICE), a longitudinal practice-based course for first-year medical students. While IPE courses focus on student-to-student interaction, ICE focuses on introducing students to interprofessional collaboration. Students attend 14 sessions at one of 18 different clinical sites. They work directly with different health professionals from among 17 possible professions, including nurses, pharmacists, social workers, and respiratory, occupational, and physical therapists. Between 2015 and 2016, 167 students completed the course, and 81 completed the end-of-course evaluation. Students agreed or strongly agreed that ICE meaningfully contributed to their understanding of healthcare teams and different professional roles (86%), improved their understanding of healthcare systems (84%), improved their ability to communicate with healthcare professionals (61%), and improved their ability to work on interprofessional teams (65%). Select themes from narrative comments suggest that clinical immersion improves understanding of professional roles, helps students understand their own future roles in healthcare teams, and increases awareness of and respect for other professionals, with the potential to change future practice. ICE may be a template for other schools wishing to expand their current educational offerings, by engaging learners in more authentic, longitudinal clinical experiences with practicing healthcare professionals.

  1. Image-guided regularization level set evolution for MR image segmentation and bias field correction.

    Science.gov (United States)

    Wang, Lingfeng; Pan, Chunhong

    2014-01-01

    Magnetic resonance (MR) image segmentation is a crucial step in surgical and treatment planning. In this paper, we propose a level-set-based segmentation method for MR images with intensity inhomogeneous problem. To tackle the initialization sensitivity problem, we propose a new image-guided regularization to restrict the level set function. The maximum a posteriori inference is adopted to unify segmentation and bias field correction within a single framework. Under this framework, both the contour prior and the bias field prior are fully used. As a result, the image intensity inhomogeneity can be well solved. Extensive experiments are provided to evaluate the proposed method, showing significant improvements in both segmentation and bias field correction accuracies as compared with other state-of-the-art approaches. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Content Based Medical Image Retrieval for Histopathological, CT and MRI Images

    Directory of Open Access Journals (Sweden)

    Swarnambiga AYYACHAMY

    2013-09-01

    Full Text Available A content based approach is followed for medical images. The purpose of this study is to access the stability of these methods for medical image retrieval. The methods used in color based retrieval for histopathological images are color co-occurrence matrix (CCM and histogram with meta features. For texture based retrieval GLCM (gray level co-occurrence matrix and local binary pattern (LBP were used. For shape based retrieval canny edge detection and otsu‘s method with multivariable threshold were used. Texture and shape based retrieval were implemented using MRI (magnetic resonance images. The most remarkable characteristics of the article are its content based approach for each medical imaging modality. Our efforts were focused on the initial visual search. From our experiment, histogram with meta features in color based retrieval for histopathological images shows a precision of 60 % and recall of 30 %. Whereas GLCM in texture based retrieval for MRI images shows a precision of 70 % and recall of 20 %. Shape based retrieval for MRI images shows a precision of 50% and recall of 25 %. The retrieval results shows that this simple approach is successful.

  3. Chemistry Graduate Teaching Assistants' Experiences in Academic Laboratories and Development of a Teaching Self-image

    Science.gov (United States)

    Gatlin, Todd Adam

    Graduate teaching assistants (GTAs) play a prominent role in chemistry laboratory instruction at research based universities. They teach almost all undergraduate chemistry laboratory courses. However, their role in laboratory instruction has often been overlooked in educational research. Interest in chemistry GTAs has been placed on training and their perceived expectations, but less attention has been paid to their experiences or their potential benefits from teaching. This work was designed to investigate GTAs' experiences in and benefits from laboratory instructional environments. This dissertation includes three related studies on GTAs' experiences teaching in general chemistry laboratories. Qualitative methods were used for each study. First, phenomenological analysis was used to explore GTAs' experiences in an expository laboratory program. Post-teaching interviews were the primary data source. GTAs experiences were described in three dimensions: doing, knowing, and transferring. Gains available to GTAs revolved around general teaching skills. However, no gains specifically related to scientific development were found in this laboratory format. Case-study methods were used to explore and illustrate ways GTAs develop a GTA self-image---the way they see themselves as instructors. Two general chemistry laboratory programs that represent two very different instructional frameworks were chosen for the context of this study. The first program used a cooperative project-based approach. The second program used weekly, verification-type activities. End of the semester interviews were collected and served as the primary data source. A follow-up case study of a new cohort of GTAs in the cooperative problem-based laboratory was undertaken to investigate changes in GTAs' self-images over the course of one semester. Pre-semester and post-semester interviews served as the primary data source. Findings suggest that GTAs' construction of their self-image is shaped through the

  4. Image-guided radiofrequency ablation of Bosniak category III or IV cystic renal tumors: initial clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Kwan; Kim, Chan Kyo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea); Lee, Hyun Moo [Sungkyunkwan University School of Medicine, Department of Urology, Samsung Medical Center, Seoul (Korea)

    2008-07-15

    The purpose of this study was to assess the efficacy of image-guided radiofrequency (RF) ablation of cystic renal tumors. Between November 2005 and August 2007, computed tomography (CT) or ultrasound-guided RF ablation was performed in nine patients with 14 Bosniak category III (n = 5) or IV (n = 9) cystic renal tumors using an internally cooled RF ablation system. We evaluated the number of sessions, cycles and duration of energy application, treatment results, lesion size change, and complications. Together the cystic renal tumors required 15 sessions and 23 cycles of energy application. The duration of energy application per one tumor ablation ranged from 1 to 12 min (mean 6 min). The last follow-up CT indicated complete coagulation of 14/14 (100%) lesions. None of these tumors had recurred within 1-19 months (mean 8 months). The maximum diameter of the cystic renal tumors was significantly reduced from 2.5 {+-} 0.6 cm before ablation to 1.7 {+-} 0.7 cm at the last follow-up CT (P < 0.01). Complications were pneumothorax (n = 2), inguinal paresthesia (n = 1), and arteriovenous fistula (n = 1). Image-guided RF ablation is an effective treatment for Bosniak category III or IV cystic renal tumors, which might need relatively shorter duration of energy application than purely solid renal tumors of the same size. (orig.)

  5. Image-guided radiofrequency ablation of Bosniak category III or IV cystic renal tumors: initial clinical experience

    International Nuclear Information System (INIS)

    Park, Byung Kwan; Kim, Chan Kyo; Lee, Hyun Moo

    2008-01-01

    The purpose of this study was to assess the efficacy of image-guided radiofrequency (RF) ablation of cystic renal tumors. Between November 2005 and August 2007, computed tomography (CT) or ultrasound-guided RF ablation was performed in nine patients with 14 Bosniak category III (n = 5) or IV (n = 9) cystic renal tumors using an internally cooled RF ablation system. We evaluated the number of sessions, cycles and duration of energy application, treatment results, lesion size change, and complications. Together the cystic renal tumors required 15 sessions and 23 cycles of energy application. The duration of energy application per one tumor ablation ranged from 1 to 12 min (mean 6 min). The last follow-up CT indicated complete coagulation of 14/14 (100%) lesions. None of these tumors had recurred within 1-19 months (mean 8 months). The maximum diameter of the cystic renal tumors was significantly reduced from 2.5 ± 0.6 cm before ablation to 1.7 ± 0.7 cm at the last follow-up CT (P < 0.01). Complications were pneumothorax (n = 2), inguinal paresthesia (n = 1), and arteriovenous fistula (n = 1). Image-guided RF ablation is an effective treatment for Bosniak category III or IV cystic renal tumors, which might need relatively shorter duration of energy application than purely solid renal tumors of the same size. (orig.)

  6. The Role of Consumer Experiences in Building the image of brands: A Study in Airlines

    Directory of Open Access Journals (Sweden)

    Ana Iris Tomás Vasconcelos

    2015-04-01

    Full Text Available Studies on brand and consumer experience gained emphasis from the twentieth century, however the relationship between these themes still has gaps. Therefore, this study examines the role of consumer experiences in building the brand image through the identification of thoughts, feelings and actions arising from consumer experiences with airlines, and the types of associations that the consumer makes such marks. Therefore, a variation of qualitative critical incident technique was used, considering those remembered experiences that have excelled in consumer perception, interviewing ten users of air services, based on a two parts semi-structured form: description of experiences with airlines and information about the image of the brands of airlines. The analyzed data have revealed that thoughts, feelings and actions arising from consumer experiences become important elements in shaping the perception of brands of airlines. Through the consumption experience, consumers mainly use the service attributes to build their perception of the marks of the airlines. These attributes are used either directly as to support other types of associations such as those related to company size.

  7. Simulation of rod drop experiments in the initial cores of Loviisa and Mochovce

    International Nuclear Information System (INIS)

    Kaloinen, E.; Kyrki-Rajamaeki, R.; Wasastjerna, F.

    1999-01-01

    Interpretation of rod drop measurements during startup tests of the Loviisa reactors has earlier been studied with two-dimensional core calculations using a spatial prompt jump approximation. In these calculations the prediction for the reactivity meter reading was lower than the measured values by 25%. Another approach to solve the problem is simulation of the rod drop experiment with dynamic core calculations coupled with out of core calculations to estimate the response of ex-core ionization chambers for the reactivity meter. This report described the calculations performed with the three-dimensional dynamic code HEXTRAN for prediction of the reactivity meter readings in rod drop experiments in initial cores of the WWER-440 reactors. (Authors)

  8. The experience turn of the Danish periphery

    DEFF Research Database (Denmark)

    Lorentzen, Anne

    2013-01-01

    strategic management, is more encompassing than the related notion of cultural economy, and its application in urban strategies aims to promote (1) new forms of business innovation, (2) the development of new industries and (3) the development of place as a factor of attraction. The article proceeds...... constructed by the initiatives of public, private and civic actors over more than a decade, until it finally became institutionalized in official municipal policy and organizations. The many initiatives materialized in a considerable enhancement of the local cultural and leisure supply, urban refurbishment......, business innovation and a change of urban image from industrial city to experience city. The experience economy mainly became institutionalized as a reinterpretation and development of welfare services from a consumer perspective. As a municipal strategy the experience economy concept is faced with two...

  9. A necessary evil: The experiences of men with prostate cancer undergoing imaging procedures

    International Nuclear Information System (INIS)

    Mathers, Sandra A.; McKenzie, Graham A.; Robertson, Elizabeth M.

    2011-01-01

    Objective: This study sought to explore the experience of people with a diagnosis of cancer while attending for imaging procedures. The diversity and complexity of the issues described within individual interviews made it impossible to include all cancer groups in one paper. This paper focuses on the cohort of men with prostate cancer. Method: An opportunistic sample of men (n = 8) were recruited from Cancer Support Groups throughout the North-east of Scotland. A qualitative, exploratory and retrospective study design was employed using semi-structured interviews. All interviews were audio taped and full transcripts produced. These were analysed following the recommendations of Miles and Huberman (1994). Main findings: Men were keen to take part in the study, and described experiences from pre-diagnosis to the date of interview. Participants reported different routes to diagnosis, then having a range of diagnostic procedures indicating a very personal journey with no standardised approach. Imaging was not seen as a separate event but part of the whole story. The provision of radiology patient information material was haphazard. Participants could explain why they were having these procedures, and saw them as a 'necessary evil'. The provision of results of their tests was complex and chaotic, and was described as an anxious time. Conclusion: This study provides a unique insight into the experiences of men with prostate cancer relating to their attendance for imaging. Health professionals need to listen to their patients and learn, in order to provide a high quality, patient-centred imaging service.

  10. A necessary evil: The experiences of men with prostate cancer undergoing imaging procedures

    Energy Technology Data Exchange (ETDEWEB)

    Mathers, Sandra A., E-mail: s.mathers@rgu.ac.uk [Robert Gordon University, Faculty of Health and Social Care, Garthdee Road, Aberdeen AB10 7QG (United Kingdom); McKenzie, Graham A.; Robertson, Elizabeth M. [Robert Gordon University, Faculty of Health and Social Care, Garthdee Road, Aberdeen AB10 7QG (United Kingdom)

    2011-11-15

    Objective: This study sought to explore the experience of people with a diagnosis of cancer while attending for imaging procedures. The diversity and complexity of the issues described within individual interviews made it impossible to include all cancer groups in one paper. This paper focuses on the cohort of men with prostate cancer. Method: An opportunistic sample of men (n = 8) were recruited from Cancer Support Groups throughout the North-east of Scotland. A qualitative, exploratory and retrospective study design was employed using semi-structured interviews. All interviews were audio taped and full transcripts produced. These were analysed following the recommendations of Miles and Huberman (1994). Main findings: Men were keen to take part in the study, and described experiences from pre-diagnosis to the date of interview. Participants reported different routes to diagnosis, then having a range of diagnostic procedures indicating a very personal journey with no standardised approach. Imaging was not seen as a separate event but part of the whole story. The provision of radiology patient information material was haphazard. Participants could explain why they were having these procedures, and saw them as a 'necessary evil'. The provision of results of their tests was complex and chaotic, and was described as an anxious time. Conclusion: This study provides a unique insight into the experiences of men with prostate cancer relating to their attendance for imaging. Health professionals need to listen to their patients and learn, in order to provide a high quality, patient-centred imaging service.

  11. Initial application of a geometric QA tool for integrated MV and kV imaging systems on three image guided radiotherapy systems.

    Science.gov (United States)

    Mao, Weihua; Speiser, Michael; Medin, Paul; Papiez, Lech; Solberg, Timothy; Xing, Lei

    2011-05-01

    0.8 degrees, and detector center offsets up to 3 mm, were observed for three linacs, with the exception of the Vero, for which a significant center offset of one kV detector (prior to machine commissioning) was observed. In contrast, the gimbal-based MV source positioning of the Vero demonstrated differences between observed and expected source positions of less than 0.2 mm, both with and without gimbal rotation. This initial application of this geometric QA tool shows promise as a universal, independent tool for quantitative evaluation of geometric accuracies of both MV and integrated kV imaging systems across a range of platforms. It provides nine geometric parameters of any imaging system at every gantry angle as well as the isocenter coincidence of the MV and kV image systems.

  12. Experimental analysis of quasi-static and dynamic fracture initiation toughness of gy4 armor steel material

    Science.gov (United States)

    Ren, Peng; Guo, Zitao

    Quasi-static and dynamic fracture initiation toughness of gy4 armour steel material are investigated using three point bend specimen. The modified split Hopkinson pressure bar (SHPB) apparatus with digital image correlation (DIC) system is applied to dynamic loading experiments. Full-field deformation measurements are obtained by using DIC to elucidate on the strain fields associated with the mechanical response. A series of experiments are conducted at different strain rate ranging from 10-3 s-1 to 103 s-1, and the loading rate on the fracture initiation toughness is investigated. Specially, the scanning electron microscope imaging technique is used to investigate the fracture failure micromechanism of fracture surfaces. The gy4 armour steel material fracture toughness is found to be sensitive to strain rate and higher for dynamic loading as compared to quasi-static loading. This work is supported by National Nature Science Foundation under Grant 51509115.

  13. The association between continuous antibiotic prophylaxis and UTI from birth until initial postnatal imaging evaluation among newborns with antenatal hydronephrosis.

    Science.gov (United States)

    Varda, B K; Finkelstein, J B; Wang, H-H; Logvinenko, T; Nelson, C P

    2018-05-29

    There is a lack of consensus regarding the use of continuous antibiotic prophylaxis (CAP) during the interval between birth and initial postnatal imaging in infants with a history of antenatal urinary tract dilation (AUTD). To determine the incidence of urinary tract infection (UTI), and the association between CAP use and UTI during the interval between birth and the first postnatal renal ultrasound (RUS) in infants with AUTD. A single-institution, retrospective cohort study of newborns with a history of AUTD. Infants undergoing RUS within 3 months of birth for an indication of 'hydronephrosis' between 2012 and 2014 were identified. A random sample of 500 infants was selected; six were excluded for concomitant congenital anomalies. Baseline patient (sex, race, insurance) and clinical characteristics (circumcision status, UTD risk score, receipt of CAP, UTI prior to RUS, age at UTI, and age at RUS) were collected via retrospective chart review. Descriptive statistics were calculated. To adjust for receipt of CAP, propensity score adjusted univariate logistic regression for UTI based on CAP status was performed. Among the 494 infants with AUTD, 157 (32%) received CAP. Infants with normal/low-risk UTD scores were less likely to receive CAP than those with medium/high-risk UTD (23% vs 77%; P UTI prior to imaging: six (1.8%) without CAP vs one (0.64%) with CAP (P = 0.44). The median age at UTI was 59 days (range 2-84); among those with UTI, initial imaging occurred significantly later (66 vs 28 days; P = 0.001). The propensity score adjusted odds of developing UTI with CAP (vs without) was 0.93 (95% CI 0.10-8.32; P = 0.95). The Summary Figure describes the infants with UTI. The incidence of UTI prior to initial neonatal imaging in newborns with AUTD was low. Use of CAP was not associated with UTI incidence after adjusting for UTD severity. Routine use of CAP in newborns with AUTD prior to initial imaging may be of limited benefit in most patients. Copyright

  14. Optimization of accelerator target and detector for portal imaging using Monte Carlo simulation and experiment

    International Nuclear Information System (INIS)

    Flampouri, S.; Evans, P.M.; Partridge, M.; Nahum, A.E.; Verhaegen, A.E.; Spezi, E.

    2002-01-01

    Megavoltage portal images suffer from poor quality compared to those produced with kilovoltage x-rays. Several authors have shown that the image quality can be improved by modifying the linear accelerator to generate more low-energy photons. This work addresses the problem of using Monte Carlo simulation and experiment to optimize the beam and detector combination to maximize image quality for a given patient thickness. A simple model of the whole imaging chain was developed for investigation of the effect of the target parameters on the quality of the image. The optimum targets (6 mm thick aluminium and 1.6 mm copper) were installed in an Elekta SL25 accelerator. The first beam will be referred to as Al6 and the second as Cu1.6. A tissue-equivalent contrast phantom was imaged with the 6 MV standard photon beam and the experimental beams with standard radiotherapy and mammography film/screen systems. The arrangement with a thin Al target/mammography system improved the contrast from 1.4 cm bone in 5 cm water to 19% compared with 2% for the standard arrangement of a thick, high-Z target/radiotherapy verification system. The linac/phantom/detector system was simulated with the BEAM/EGS4 Monte Carlo code. Contrast calculated from the predicted images was in good agreement with the experiment (to within 2.5%). The use of MC techniques to predict images accurately, taking into account the whole imaging system, is a powerful new method for portal imaging system design optimization. (author)

  15. Initial clinical experiences with dopamine D{sub 2} receptor imaging by means of 2`-iodospiperone and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yonekura, Yoshiharu [Fukui Medical Schoool, Matsuoka (Japan). Biomedical Imaging Research Center; Saji, Hideo; Iwasaki, Yasushi [and others

    1995-08-01

    Dopamine D{sub 2} receptor imaging was performed with {sup 123}I labeled 2`-iodospiperone (2`-ISP) and single-photon emission computed tomography (SPECT) in 9 patients: 4 with idiopathic Parkinson`s disease, 2 with parkinsonism, 1 with Wilson`s disease and 2 with pituitary tumor, and the results were compared with the data for 9 normal subjects. Following an intravenous injection of {sup 123}I-2`-ISP, early (within 30 min) and late (between 2 and 4 hr) SPECT images were obtained by means of a multi-detector SPECT scanner or a rotating gamma camera. In normal subjects, early SPECT images demonstrated uniform distribution of radioactivity in the cerebral gray matter and cerebellum reflecting regional cerebral blood flow, whereas late SPECT images showed high radioactivity only in the basal ganglia. All the patients with Parkinson`s disease also demonstrated symmetrical basal ganglia uptake in the late SPECT images, but it was diminished in parkinsonism and Wilson`s disease. One patient with a growth hormone-producing pituitary tumor had a positive uptake in the tumor. These preliminary clinical data demonstrated that 2`-ISP can be used for SPECT imaging of D{sub 2} dopamine receptors and may be of clinical value for the diagnosis and planning of the treatment of neurological diseases. (author).

  16. Intraoperative 3-tesla MRI in the management of paediatric cranial tumours - initial experience

    International Nuclear Information System (INIS)

    Avula, Shivaram; Garlick, Deborah; Abernethy, Laurence J.; Mallucci, Connor L.; Pizer, Barry; Crooks, Daniel

    2012-01-01

    Intraoperative MRI (ioMRI) has been gaining recognition because of its value in the neurosurgical management of cranial tumours. There is limited documentation of its value in children. To review the initial experience of a paediatric 3-Tesla ioMRI unit in the management of cranial tumours. Thirty-eight children underwent ioMRI during 40 cranial tumour resections using a 3-Tesla MR scanner co-located with the neurosurgical operating theatre. IoMRI was performed to assess the extent of tumour resection and/or to update neuronavigation. The intraoperative and follow-up scans, and the clinical records were reviewed. In 27/40 operations, complete resection was intended. IoMRI confirmed complete resection in 15/27 (56%). As a consequence, surgical resection was extended in 5/27 (19%). In 6/27 (22%), ioMRI was equivocal for residual tumour. In 13/40 (33%) operations, the surgical aim was to partially resect the tumour. In 7 of the 13 (54%), surgical resection was extended following ioMRI. In our initial experience, ioMRI has increased the rate of complete resection, with intraoperative surgical strategy being modified in 30% of procedures. Collaborative analysis of ioMRI by the radiologist and neurosurgeon is vital to avoid errors in interpretation. (orig.)

  17. Intraoperative 3-tesla MRI in the management of paediatric cranial tumours - initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Avula, Shivaram; Garlick, Deborah; Abernethy, Laurence J. [Alder Hey Children' s NHS Foundation Trust, Department of Radiology, Liverpool (United Kingdom); Mallucci, Connor L. [Alder Hey Children' s Hospital, Department of Neurosurgery, Liverpool (United Kingdom); Pizer, Barry [Alder Hey Children' s Hospital, Department of Oncology, Liverpool (United Kingdom); Crooks, Daniel [Walton Centre for Neurology and Neurosurgery, Department of Pathology, Liverpool (United Kingdom)

    2012-02-15

    Intraoperative MRI (ioMRI) has been gaining recognition because of its value in the neurosurgical management of cranial tumours. There is limited documentation of its value in children. To review the initial experience of a paediatric 3-Tesla ioMRI unit in the management of cranial tumours. Thirty-eight children underwent ioMRI during 40 cranial tumour resections using a 3-Tesla MR scanner co-located with the neurosurgical operating theatre. IoMRI was performed to assess the extent of tumour resection and/or to update neuronavigation. The intraoperative and follow-up scans, and the clinical records were reviewed. In 27/40 operations, complete resection was intended. IoMRI confirmed complete resection in 15/27 (56%). As a consequence, surgical resection was extended in 5/27 (19%). In 6/27 (22%), ioMRI was equivocal for residual tumour. In 13/40 (33%) operations, the surgical aim was to partially resect the tumour. In 7 of the 13 (54%), surgical resection was extended following ioMRI. In our initial experience, ioMRI has increased the rate of complete resection, with intraoperative surgical strategy being modified in 30% of procedures. Collaborative analysis of ioMRI by the radiologist and neurosurgeon is vital to avoid errors in interpretation. (orig.)

  18. Visible imaging of edge turbulence in NSTX

    International Nuclear Information System (INIS)

    Zweben, S.; Maqueda, R.; Hill, K.; Johnson, D.

    2000-01-01

    Edge plasma turbulence in tokamaks and stellarators is believed to cause the radical heat and particle flux across the separatrix and into the scrape-off-layers of these devices. This paper describes initial measurements of 2-D space-time structure of the edge density turbulence made using a visible imaging diagnostic in the National Spherical Torus Experiment (NSTX). The structure of the edge turbulence is most clearly visible using a method of gas puff imaging to locally illuminate the edge density turbulence

  19. Visible imaging of edge turbulence in NSTX

    International Nuclear Information System (INIS)

    S. Zweben; R. Maqueda; K. Hill; D. Johnson; S. Kaye; H. Kugel; F. Levinton; R. Maingi; L. Roquemore; S. Sabbagh; G. Wurden

    2000-01-01

    Edge plasma turbulence in tokamaks and stellarators is believed to cause the radial heat and particle flux across the separatrix and into the scrape-off-layers of these devices. This paper describes initial measurements of 2-D space-time structure of the edge density turbulence made using a visible imaging diagnostic in the National Spherical Torus Experiment (NSTX). The structure of the edge turbulence is most clearly visible using a method of ''gas puff imaging'' to locally illuminate the edge density turbulence

  20. Experience in initial training required for the recognition of the qualified RP expert in Spain

    International Nuclear Information System (INIS)

    Rodriguez Suarez, M.; Marco Arboli, M.; Menarguez, J.

    2003-01-01

    An important point of the actions inside the European framework to achieve the harmonisation of the training programmes and recognition was included in the European directive 96/29/Euratom which includes definition and specific tasks of the European Qualified Expert on Radiation Protection (RP). Basic syllabus for training of those experts was developed in the communication 98/C 133/03 concerning BSS applications. Although, in the Spanish education system, the training and recognition requirements of the high level qualified experts on RP was defined since 1977, until 2001, the figure of the Technical Qualified Expert on RP does not appear in the legal framework. In December 2002, a new regulation of the Spanish Regulatory Body, CSN, about qualifications to obtain the recognition of RP Expert in Spain (both high qualified and technical RP experts) was published. Concerning the qualified expert on RP, (RP Officer), responsible of the RP Service, which takes charge of the effective protection and advise radioactive and nuclear facilities in Rp aspects,has to be authorised by the regulatory body. to obtain the RP officer diploma, conceded by the CSN, an initial training of 300 hours and a three-year minimum experience are required (for X-ray installation a 6-month experience is enough). The technical qualified expert on RP is the worker who carried out the tasks in the a RP Service under the supervision of the RP officer. A Technician Qualified Expert on RP does not need an specific accreditation of the Regulatory Body, but an initial RP training and a three-month minimum experience are required and has hold a certificate by the RP officer. Continuous training is also required and as well has to receive a certificate from the RP officer. Since 1977, The Institute for energy Studies has been implementing specific training courses for those professionals who want to obtain the diploma of RP officer (high degree qualified RP expert), conceded by the CSN. Since then

  1. Initial experience with SPECT imaging of the brain using I-123 p-iodoamphetamine in focal epilepsy

    International Nuclear Information System (INIS)

    LaManna, M.M.; Sussman, N.M.; Harner, R.N.

    1989-01-01

    Nineteen patients with complex partial seizures refractory to medical treatment were examined with routine electroencephalography (EEG), video EEG monitoring, computed tomography or magnetic resonance imaging, neuropsychological tests and interictal single photon emission computed tomography (SPECT) with I-123 iodoamphetamine (INT). In 18 patients, SPECT identified areas of focal reduction in tracer uptake that correlated with the epileptogenic focus identified on the EEG. In addition, SPECT disclosed other areas of neurologic dysfunction as elicited on neuropsychological tests. Thus, IMP SPECT is a useful tool for localizing epileptogenic foci and their associated dynamic deficits

  2. Imaging of tumor viability in lung cancer. Initial results using 23Na-MRI

    International Nuclear Information System (INIS)

    Henzler, T.; Apfaltrer, P.; Haneder, S.; Schoenberg, S.O.; Fink, C.; Konstandin, S.; Schad, L.; Schmid-Bindert, G.; Manegold, C.; Wenz, F.

    2012-01-01

    23 Na-MRI has been proposed as a potential imaging biomarker for the assessment of tumor viability and the evaluation of therapy response but has not yet been evaluated in patients with lung cancer. We aimed to assess the feasibility of 23 Na-MRI in patients with lung cancer. Three patients with stage IV adenocarcinoma of the lung were examined on a clinical 3 Tesla MRI system (Magnetom TimTrio, Siemens Healthcare, Erlangen, Germany). Feasibility of 23 Na-MRI images was proven by comparison and fusion of 23 Na-MRI with 1 H-MR, CT and FDG-PET-CT images. 23 Na signal intensities (SI) of tumor and cerebrospinal fluid (CSF) of the spinal canal were measured and the SI ratio in tumor and CSF was calculated. One chemonaive patient was examined before and after the initiation of combination therapy (Carboplatin, Gemcitabin, Cetuximab). All 23 Na-MRI examinations were successfully completed and were of diagnostic quality. Fusion of 23 Na-MRI images with 1 H-MRI, CT and FDG-PET-CT was feasible in all patients and showed differences in solid and necrotic tumor areas. The mean tumor SI and the tumor/CSF SI ratio were 13.3 ± 1.8 x 103 and 0.83 ± 0.14, respectively. In necrotic tumors, as suggested by central non-FDG-avid areas, the mean tumor SI and the tumor/CSF ratio were 19.4 x 103 and 1.10, respectively. 23 Na-MRI is feasible in patients with lung cancer and could provide valuable functional molecular information regarding tumor viability, and potentially treatment response. (orig.)

  3. Modifying mixing and instability growth through the adjustment of initial conditions in a high-energy-density counter-propagating shear experiment on OMEGA

    International Nuclear Information System (INIS)

    Merritt, E. C.; Doss, F. W.; Loomis, E. N.; Flippo, K. A.; Kline, J. L.

    2015-01-01

    Counter-propagating shear experiments conducted at the OMEGA Laser Facility have been evaluating the effect of target initial conditions, specifically the characteristics of a tracer foil located at the shear boundary, on Kelvin-Helmholtz instability evolution and experiment transition toward nonlinearity and turbulence in the high-energy-density (HED) regime. Experiments are focused on both identifying and uncoupling the dependence of the model initial turbulent length scale in variable-density turbulence models of k-ϵ type on competing physical instability seed lengths as well as developing a path toward fully developed turbulent HED experiments. We present results from a series of experiments controllably and independently varying two initial types of scale lengths in the experiment: the thickness and surface roughness (surface perturbation scale spectrum) of a tracer layer at the shear interface. We show that decreasing the layer thickness and increasing the surface roughness both have the ability to increase the relative mixing in the system, and thus theoretically decrease the time required to begin transitioning to turbulence in the system. We also show that we can connect a change in observed mix width growth due to increased foil surface roughness to an analytically predicted change in model initial turbulent scale lengths

  4. Initial Experience with the Machine Protection System for LHC

    CERN Document Server

    Schmidt, Ruediger; Dehning, Bernd; Ferro-Luzzi, Massimiliano; Goddard, Brennan; Lamont, Mike; Siemko, Andrzej; Uythoven, Jan; Wenninger, Jorg; Zerlauth, Markus

    2010-01-01

    For nominal beam parameters at 7 TeV/c each proton beam with a stored energy of 362 MJ threatens to damage accelerator equipment in case of uncontrolled beam loss. These parameters will only be reached after some years of operation, however, a small fraction of this energy is already sufficient to damage accelerator equipment or experiments. The correct functioning of the machine protection systems is vital during the different operational phases already for initial operation. When operating the complex magnet system, with and without beam, safe operation relies on the protection and interlock systems for the superconducting circuits. For safe injection and transfer of the beams from SPS to LHC, transfer line parameters are monitored, beam absorbers must be in the correct position and the LHC must be ready to accept beam. At the end of a fill and in case of failures beams must be properly extracted onto the dump blocks, for some types of failure within less than few hundred microseconds. Safe operation requir...

  5. PICTURE: a sounding rocket experiment for direct imaging of an extrasolar planetary environment

    Science.gov (United States)

    Mendillo, Christopher B.; Hicks, Brian A.; Cook, Timothy A.; Bifano, Thomas G.; Content, David A.; Lane, Benjamin F.; Levine, B. Martin; Rabin, Douglas; Rao, Shanti R.; Samuele, Rocco; Schmidtlin, Edouard; Shao, Michael; Wallace, J. Kent; Chakrabarti, Supriya

    2012-09-01

    The Planetary Imaging Concept Testbed Using a Rocket Experiment (PICTURE 36.225 UG) was designed to directly image the exozodiacal dust disk of ǫ Eridani (K2V, 3.22 pc) down to an inner radius of 1.5 AU. PICTURE carried four key enabling technologies on board a NASA sounding rocket at 4:25 MDT on October 8th, 2011: a 0.5 m light-weight primary mirror (4.5 kg), a visible nulling coronagraph (VNC) (600-750 nm), a 32x32 element MEMS deformable mirror and a milliarcsecond-class fine pointing system. Unfortunately, due to a telemetry failure, the PICTURE mission did not achieve scientific success. Nonetheless, this flight validated the flight-worthiness of the lightweight primary and the VNC. The fine pointing system, a key requirement for future planet-imaging missions, demonstrated 5.1 mas RMS in-flight pointing stability. We describe the experiment, its subsystems and flight results. We outline the challenges we faced in developing this complex payload and our technical approaches.

  6. Operation of the tokamak fusion test reactor tritium systems during initial tritium experiments

    International Nuclear Information System (INIS)

    Anderson, J.L.; Gentile, C.; Kalish, M.; Kamperschroer, J.; Kozub, T.; LaMarche, P.; Murray, H.; Nagy, A.; Raftopoulos, S.; Rossmassler, R.; Sissingh, R.; Swanson, J.; Tulipano, F.; Viola, M.; Voorhees, D.; Walters, R.T.

    1995-01-01

    The high power D-T experiments on the tokamak fusion test reactor (TFTR) at the Princeton Plasma Physics Laboratory commenced in November 1993. During initial operation of the tritium systems a number of start-up problems surfaced and had to be corrected. These were corrected through a series of system modifications and upgrades and by repair of failed or inadequate components. Even as these operational concerns were being addressed, the tritium systems continued to support D-T operations on the tokamak. During the first six months of D-T operations more than 107kCi of tritium were processed successfully by the tritium systems. D-T experiments conducted at TFTR during this period provided significant new data. Fusion power in excess of 9MW was achieved in May 1994. This paper describes some of the early start-up issues, and reports on the operation of the tritium system and the tritium tracking and accounting system during the early phase of TFTR D-T experiments. (orig.)

  7. Sodium MR imaging of human brain neoplasms. A preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Shu; Yoshikawa, Kohki; Takakura, Kintomo; Iio, Masahiro

    1988-08-01

    We reported the experience of the sodium magnetic resonance imaging of 5 patients with brain tumors (4 astrocytomas and 1 craniopharyngioma), using a Siemens 1.5 Tesla superconductive magnet. We used two-dimensional Fourier imaging with a spin-echo scanning sequence (and with the repetition time of 140 msec and the echo time of 11 - 14 msec). The radiofrequency was maintained at 17 MHz. Sodium MR imaging was achieved with a 64 x 64 data acquisition (30 mm slice thickness) in 19.1 min. On the sodium MRI, all four astrocytomas, along with the eye balls and the cerebrospinal fluid spaces, appeared as high-intensity areas. Peritumoral edema is also visualized as highly intense, so that it is difficult to discriminate tumor extent from the surrounding edema. Our comparative studies with malignant glioma cases using the same equipment are needed to clarify the relationship between sodium signal intensities and the malignancy of gliomas, and to evaluate the potential clinical utility of sodium MRI. A craniopharyngioma than contained a yellowish cystic fluid with a sodium concentration as high as CSF was shown on sodium MRI as a mass with highly intense signals. The ability to differentiate extracellular from intracellular sodium, that has been studied by several investigators, would greatly augment the clinical specificity of MR imaging.

  8. Fabrication of luminescent hydroxyapatite nanorods through surface-initiated RAFT polymerization: Characterization, biological imaging and drug delivery applications

    Energy Technology Data Exchange (ETDEWEB)

    Heng, Chunning [Shaanxi Key Laboratory of Degradable Biomedical Materials, Shaanxi R& D Center of Biomaterials and Fermentation Engineering, School of Chemical and Engineering, Northwest University, Xi’an, 710069 (China); Department of Chemistry, Nanchang University, 999 Xuefu Avenue, Nanchang 330031 (China); Zheng, Xiaoyan [Shaanxi Key Laboratory of Degradable Biomedical Materials, Shaanxi R& D Center of Biomaterials and Fermentation Engineering, School of Chemical and Engineering, Northwest University, Xi’an, 710069 (China); Liu, Meiying; Xu, Dazhuang; Huang, Hongye; Deng, Fengjie [Department of Chemistry, Nanchang University, 999 Xuefu Avenue, Nanchang 330031 (China); Hui, Junfeng, E-mail: huijunfeng@126.com [Shaanxi Key Laboratory of Degradable Biomedical Materials, Shaanxi R& D Center of Biomaterials and Fermentation Engineering, School of Chemical and Engineering, Northwest University, Xi’an, 710069 (China); Zhang, Xiaoyong, E-mail: xiaoyongzhang1980@gmail.com [Department of Chemistry, Nanchang University, 999 Xuefu Avenue, Nanchang 330031 (China); Wei, Yen, E-mail: weiyen@tsinghua.edu.cn [Department of Chemistry and the Tsinghua Center for Frontier Polymer Research, Tsinghua University, Beijing, 100084 (China)

    2016-11-15

    Highlights: • Hydrophobic hydroxyapatite nanorods were obtained from hydrothermal synthesis. • Surface initiated RAFT polymerization was adopted to surface modification of hydroxyapatite nanorods. • These modified hydroxyapatite nanorods showed high water dispersibility and biocompatibility. • These modified hydroxyapatite nanorods can be used for controlled drug delivery. - Abstract: Hydroxyapatite nanomaterials as an important class of nanomaterials, have been widely applied for different biomedical applications for their excellent biocompatibility, biodegradation potential and low cost. In this work, hydroxyapatite nanorods with uniform size and morphology were prepared through hydrothermal synthesis. The surfaces of these hydroxyapatite nanorods are covered with hydrophobic oleic acid, making them poor dispersibility in aqueous solution and difficult for biomedical applications. To overcome this issue, a simple surface initiated polymerization strategy has been developed via combination of the surface ligand exchange and reversible addition fragmentation chain transfer (RAFT) polymerization. Hydroxyapatite nanorods were first modified with Riboflavin-5-phosphate sodium (RPSSD) via ligand exchange reaction between the phosphate group of RPSSD and oleic acid. Then hydroxyl group of nHAp-RPSSD was used to immobilize chain transfer agent, which was used as the initiator for surface-initiated RAFT polymerization. The nHAp-RPSSD-poly(IA-PEGMA) nanocomposites were characterized by means of {sup 1}H nuclear magnetic resonance, Fourier transform infrared spectroscopy, fluorescence spectroscopy and thermal gravimetric analysis in detailed. The biocompatibility, biological imaging and drug delivery of nHAp-RPSSD-poly(IA-PEGMA) were also investigated. Results showed that nHAp-RPSSD-poly(IA-PEGMA) exhibited excellent water dispersibility, desirable optical properties, good biocompatibility and high drug loading capability, making them promising candidates for

  9. Fabrication of luminescent hydroxyapatite nanorods through surface-initiated RAFT polymerization: Characterization, biological imaging and drug delivery applications

    International Nuclear Information System (INIS)

    Heng, Chunning; Zheng, Xiaoyan; Liu, Meiying; Xu, Dazhuang; Huang, Hongye; Deng, Fengjie; Hui, Junfeng; Zhang, Xiaoyong; Wei, Yen

    2016-01-01

    Highlights: • Hydrophobic hydroxyapatite nanorods were obtained from hydrothermal synthesis. • Surface initiated RAFT polymerization was adopted to surface modification of hydroxyapatite nanorods. • These modified hydroxyapatite nanorods showed high water dispersibility and biocompatibility. • These modified hydroxyapatite nanorods can be used for controlled drug delivery. - Abstract: Hydroxyapatite nanomaterials as an important class of nanomaterials, have been widely applied for different biomedical applications for their excellent biocompatibility, biodegradation potential and low cost. In this work, hydroxyapatite nanorods with uniform size and morphology were prepared through hydrothermal synthesis. The surfaces of these hydroxyapatite nanorods are covered with hydrophobic oleic acid, making them poor dispersibility in aqueous solution and difficult for biomedical applications. To overcome this issue, a simple surface initiated polymerization strategy has been developed via combination of the surface ligand exchange and reversible addition fragmentation chain transfer (RAFT) polymerization. Hydroxyapatite nanorods were first modified with Riboflavin-5-phosphate sodium (RPSSD) via ligand exchange reaction between the phosphate group of RPSSD and oleic acid. Then hydroxyl group of nHAp-RPSSD was used to immobilize chain transfer agent, which was used as the initiator for surface-initiated RAFT polymerization. The nHAp-RPSSD-poly(IA-PEGMA) nanocomposites were characterized by means of "1H nuclear magnetic resonance, Fourier transform infrared spectroscopy, fluorescence spectroscopy and thermal gravimetric analysis in detailed. The biocompatibility, biological imaging and drug delivery of nHAp-RPSSD-poly(IA-PEGMA) were also investigated. Results showed that nHAp-RPSSD-poly(IA-PEGMA) exhibited excellent water dispersibility, desirable optical properties, good biocompatibility and high drug loading capability, making them promising candidates for biological

  10. A combined positron emission tomography (PET)-electron paramagnetic resonance imaging (EPRI) system: initial evaluation of a prototype scanner

    Science.gov (United States)

    Tseytlin, Mark; Stolin, Alexander V.; Guggilapu, Priyaankadevi; Bobko, Andrey A.; Khramtsov, Valery V.; Tseytlin, Oxana; Raylman, Raymond R.

    2018-05-01

    The advent of hybrid scanners, combining complementary modalities, has revolutionized the application of advanced imaging technology to clinical practice and biomedical research. In this project, we investigated the melding of two complementary, functional imaging methods: positron emission tomography (PET) and electron paramagnetic resonance imaging (EPRI). PET radiotracers can provide important information about cellular parameters, such as glucose metabolism. While EPR probes can provide assessment of tissue microenvironment, measuring oxygenation and pH, for example. Therefore, a combined PET/EPRI scanner promises to provide new insights not attainable with current imagers by simultaneous acquisition of multiple components of tissue microenvironments. To explore the simultaneous acquisition of PET and EPR images, a prototype system was created by combining two existing scanners. Specifically, a silicon photomultiplier (SiPM)-based PET scanner ring designed as a portable scanner was combined with an EPRI scanner designed for the imaging of small animals. The ability of the system to obtain simultaneous images was assessed with a small phantom consisting of four cylinders containing both a PET tracer and EPR spin probe. The resulting images demonstrated the ability to obtain contemporaneous PET and EPR images without cross-modality interference. Given the promising results from this initial investigation, the next step in this project is the construction of the next generation pre-clinical PET/EPRI scanner for multi-parametric assessment of physiologically-important parameters of tissue microenvironments.

  11. Initial Investigation of Software-Based Bone-Suppressed Imaging

    International Nuclear Information System (INIS)

    Park, Eunpyeong; Youn, Hanbean; Kim, Ho Kyung

    2015-01-01

    Chest radiography is the most widely used imaging modality in medicine. However, the diagnostic performance of chest radiography is deteriorated by the anatomical background of the patient. So, dual energy imaging (DEI) has recently been emerged and demonstrated an improved. However, the typical DEI requires more than two projections, hence causing additional patient dose. The motion artifact is another concern in the DEI. In this study, we investigate DEI-like bone-suppressed imaging based on the post processing of a single radiograph. To obtain bone-only images, we use the artificial neural network (ANN) method with the error backpropagation-based machine learning approach. The computational load of learning process of the ANN is too heavy for a practical implementation because we use the gradient descent method for the error backpropagation. We will use a more advanced error propagation method for the learning process

  12. Guided color consistency optimization for image mosaicking

    Science.gov (United States)

    Xie, Renping; Xia, Menghan; Yao, Jian; Li, Li

    2018-01-01

    This paper studies the problem of color consistency correction for sequential images with diverse color characteristics. Existing algorithms try to adjust all images to minimize color differences among images under a unified energy framework, however, the results are prone to presenting a consistent but unnatural appearance when the color difference between images is large and diverse. In our approach, this problem is addressed effectively by providing a guided initial solution for the global consistency optimization, which avoids converging to a meaningless integrated solution. First of all, to obtain the reliable intensity correspondences in overlapping regions between image pairs, we creatively propose the histogram extreme point matching algorithm which is robust to image geometrical misalignment to some extents. In the absence of the extra reference information, the guided initial solution is learned from the major tone of the original images by searching some image subset as the reference, whose color characteristics will be transferred to the others via the paths of graph analysis. Thus, the final results via global adjustment will take on a consistent color similar to the appearance of the reference image subset. Several groups of convincing experiments on both the synthetic dataset and the challenging real ones sufficiently demonstrate that the proposed approach can achieve as good or even better results compared with the state-of-the-art approaches.

  13. Investigating Image Formation with a Camera Obscura: a Study in Initial Primary Science Teacher Education

    Science.gov (United States)

    Muñoz-Franco, Granada; Criado, Ana María; García-Carmona, Antonio

    2018-04-01

    This article presents the results of a qualitative study aimed at determining the effectiveness of the camera obscura as a didactic tool to understand image formation (i.e., how it is possible to see objects and how their image is formed on the retina, and what the image formed on the retina is like compared to the object observed) in a context of scientific inquiry. The study involved 104 prospective primary teachers (PPTs) who were being trained in science teaching. To assess the effectiveness of this tool, an open questionnaire was applied before (pre-test) and after (post-test) the educational intervention. The data were analyzed by combining methods of inter- and intra-rater analysis. The results showed that more than half of the PPTs advanced in their ideas towards the desirable level of knowledge in relation to the phenomena studied. The conclusion reached is that the camera obscura, used in a context of scientific inquiry, is a useful tool for PPTs to improve their knowledge about image formation and experience in the first person an authentic scientific inquiry during their teacher training.

  14. Deep Learning Automates the Quantitative Analysis of Individual Cells in Live-Cell Imaging Experiments.

    Science.gov (United States)

    Van Valen, David A; Kudo, Takamasa; Lane, Keara M; Macklin, Derek N; Quach, Nicolas T; DeFelice, Mialy M; Maayan, Inbal; Tanouchi, Yu; Ashley, Euan A; Covert, Markus W

    2016-11-01

    Live-cell imaging has opened an exciting window into the role cellular heterogeneity plays in dynamic, living systems. A major critical challenge for this class of experiments is the problem of image segmentation, or determining which parts of a microscope image correspond to which individual cells. Current approaches require many hours of manual curation and depend on approaches that are difficult to share between labs. They are also unable to robustly segment the cytoplasms of mammalian cells. Here, we show that deep convolutional neural networks, a supervised machine learning method, can solve this challenge for multiple cell types across the domains of life. We demonstrate that this approach can robustly segment fluorescent images of cell nuclei as well as phase images of the cytoplasms of individual bacterial and mammalian cells from phase contrast images without the need for a fluorescent cytoplasmic marker. These networks also enable the simultaneous segmentation and identification of different mammalian cell types grown in co-culture. A quantitative comparison with prior methods demonstrates that convolutional neural networks have improved accuracy and lead to a significant reduction in curation time. We relay our experience in designing and optimizing deep convolutional neural networks for this task and outline several design rules that we found led to robust performance. We conclude that deep convolutional neural networks are an accurate method that require less curation time, are generalizable to a multiplicity of cell types, from bacteria to mammalian cells, and expand live-cell imaging capabilities to include multi-cell type systems.

  15. LWR aerosol containment experiments (LACE) program and initial test results

    International Nuclear Information System (INIS)

    Muhlestein, L.D.; Hilliard, R.K.; Bloom, G.R.; McCormack, J.D.; Rahn, F.J.

    1985-01-01

    The LWR aerosol containment experiments (LACE) program is described. The LACE program is being performed at the Hanford Engineer Development Laboratory (operated by Westinghouse Hanford Company) and the initial tests are sponsored by EPRI. The objectives of the LACE program are: to demonstrate, at large-scale, inherent radioactive aerosol retention behavior for postulated high consequence LWR accident situations; and to provide a data base to be used for aerosol behavior . Test results from the first phase of the LACE program are presented and discussed. Three large-scale scoping tests, simulating a containment bypass accident sequence, demonstrated the extent of agglomeration and deposition of aerosols occurring in the pipe pathway and vented auxiliary building under realistic accident conditions. Parameters varied during the scoping tests were aerosol type and steam condensation

  16. Image guided multibeam radiotherapy

    International Nuclear Information System (INIS)

    Freijo, J.L.

    2008-01-01

    This paper provides an outlook of the status of the first development stages for an updated design of radiotherapy conformal system based on tumor 3D images obtained as an output the last generation imaging machines as PET, CT and MR which offer a very valuable output in cancer diagnosis. Prospective evaluation of current software codes and acquisition of useful experience in surgical planning involves a multidisciplinary process as an initial and unavoidable stage to develop an expert software and user skills which assures the delivery of the radiation dose is done correctly in geometry and value in each voxel as a radiation protection basic condition. The validation of the images obtained has been done by the production of anatomical models of interest regions by rapid proto typing of the 3D segmented images and its evaluation by contrasting with the real regions during surgical procedures. (author)

  17. ‘It was daunting’: Experience of women with a diagnosis of breast cancer attending for breast imaging

    International Nuclear Information System (INIS)

    Mathers, Sandra A.; McKenzie, Graham A.; Robertson, Elizabeth M.

    2013-01-01

    Background: A quarter of cancer cases worldwide are attributed to breast cancer. Imaging plays an important role in diagnosis and care. Increasing value is placed on patient experience to inform service delivery. The main aim was to explore the experiences of women attending for diagnostic tests prior to and after diagnosis in order to inform practice. Methods: A convenience sample (n = 16) was recruited throughout the North-east of Scotland. A qualitative, exploratory and longitudinal study design was employed using semi-structured interviews. Twenty five interviews took place, with seven participants taking part in a single interview, a further seven and one participants taking part in two and three interviews respectively. Interviews were recorded, transcripts produced and analysed following the thematic approach. Results: Twelve participants attended imaging after discovering a breast lump and four via breast screening. Participants demonstrated differing attitudes to printed information material, and this changed over time. Imaging was ‘something to just get on and have done’ and almost without exception mammography was described as painful. The descriptions of invasive breast imaging provide a hitherto unknown insight into these procedures. Skill and attitude of staff was described as essential to the quality of the experience. This longitudinal study enabled women returning for follow-up procedures to identify their issues. Conclusion: This study provided a unique insight of the experiences of women when attending breast imaging. By listening to their narrative we can learn how services may be improved, and include this perspective to develop a quality patient-centred imaging service

  18. X-ray crystal imagers for inertial confinement fusion experiments (invited)

    International Nuclear Information System (INIS)

    Aglitskiy, Y.; Lehecka, T.; Obenschain, S.; Pawley, C.; Brown, C.M.; Seely, J.

    1999-01-01

    We report on our continued development of high resolution monochromatic x-ray imaging system based on spherically curved crystals. This system can be extensively used in the relevant experiments of the inertial confinement fusion (ICF) program. The system is currently used, but not limited to diagnostics of the targets ablatively accelerated by the Nike KrF laser. A spherically curved quartz crystal (2d=6.68703 Angstrom, R=200mm) has been used to produce monochromatic backlit images with the He-like Si resonance line (1865 eV) as the source of radiation. Another quartz crystal (2d=8.5099 Angstrom, R=200mm) with the H-like Mg resonance line (1473 eV) has been used for backlit imaging with higher contrast. The spatial resolution of the x-ray optical system is 1.7 μm in selected places and 2 - 3 μm over a larger area. A second crystal with a separate backlighter was added to the imaging system. This makes it possible to make use of all four strips of the framing camera. Time resolved, 20x magnified, backlit monochromatic images of CH planar targets driven by the Nike facility have been obtained with spatial resolution of 2.5 μm in selected places and 5 μm over the focal spot of the Nike laser. We are exploring the enhancement of this technique to the higher and lower backlighter energies. copyright 1999 American Institute of Physics

  19. Initial TMX central-cell ICRH experiments

    International Nuclear Information System (INIS)

    Molvik, A.W.; Coffield, F.E.; Falabella, S.; Griffin, D.; McVey, B.; Pickles, W.; P.

    1980-01-01

    Four topics are discussed in this report: the feasibility of applying ion cyclotron resonance heating (ICRH) in the TMX central cell, some applications of heating, the results of preliminary experiments, and plans for further ICRH experiments

  20. Tourism destinations’ image: assessment vis-à-vis the experience in theory and in the service-centric economy

    Directory of Open Access Journals (Sweden)

    Edar da Silva Añaña

    2016-05-01

    Full Text Available This paper assesses the image of tourist destinations as products in light of the experience theory, in order to evaluate relationships between both constructs. A scale is set forth to measure the image of coastal destinations, with different attractions, and to analyze the internal arrangement of the imaginary factors in light of the experience theory and the destinations as tourist products. The research is exploratory and descriptive with quantitative approach, that surveyed potential Brazilian tourists who were asked to choose one (among eight national coastal destinations to evaluate. A non-probabilistic sample of 178 consumers of different ages and income levels from various Brazilian states was surveyed. This work advances over previous theory, introducing an innovative way to see the image of destinations in the light of two factors that affect the decision to visit or not to visit a place: the arrangement of destinations as touristic products, and the experience expected to experiment when visiting the destinations.

  1. Initial Egyptian ECMO experience

    Directory of Open Access Journals (Sweden)

    Akram Abdelbary

    2016-04-01

    Results: A total of twelve patients received ECMO between January 2014 and June 2015. The mean age was 35.9 years. (range 13–65 years, 8 males, with VV ECMO in 10 patients, and VA ECMO in 2 patients. Out of ten patients of VV ECMO, one had H1N1 pneumonia, one had advanced vasculitic lung, four had bacterial pneumonia, two traumatic lung contusions and one with organophosphorus poisoning, and one undiagnosed etiology leading to severe ARDS. Lung injury score range was 3–3.8, PaO2/FiO2 (20–76 mechanical ventilation duration before ECMO 1–14 days, Femoro-jugular cannulation in 7 patients and femoro-femoral in 2 patients and femoro-subclavian in 1 patient; all patients were initially sedated and paralyzed for (2–4 days and ventilated on pressure controlled ventilation with Pmax of 25 cm H2O and PEEP of 10 cm H2O. In VA ECMO patients were cannulated percutaneously using femoro-femoral approach. One patient showed no neurologic recovery and died after 24 h, the other had CABG on ECMO however the heart didn’t recover and died after 9 days. Heparin intravenous infusion was used initially in all patients and changed to Bivalirudin in 2 patients due to possible HIT. Pump flow ranged from 2.6 to 6.5 L/min. Average support time was 12 days (range 2–24 days. Seven patients (63.3% were successfully separated from ECMO and survived to hospital discharge. Hospital length of stay ranged from 3 to 42 days, tracheostomy was done percutaneously in 5 patients and surgically in 3. Gastrointestinal bleeding occurred in 6 patients, VAP in 7 patients, neurologic complications in 1 patient with complete recovery, cardiac arrhythmias in 3 patients, pneumothorax in 9 patients, and deep venous thrombosis in 2 patients.

  2. The brain imaging data structure, a format for organizing and describing outputs of neuroimaging experiments

    OpenAIRE

    Gorgolewski, Krzysztof J.; Auer, Tibor; Calhoun, Vince D.; Craddock, R. Cameron; Das, Samir; Duff, Eugene P.; Flandin, Guillaume; Ghosh, Satrajit S.; Glatard, Tristan; Halchenko, Yaroslav O.; Handwerker, Daniel A.; Hanke, Michael; Keator, David; Li, Xiangrui; Michael, Zachary

    2016-01-01

    International audience; The development of magnetic resonance imaging (MRI) techniques has defined modern neuroimaging. Since its inception, tens of thousands of studies using techniques such as functional MRI and diffusion weighted imaging have allowed for the non-invasive study of the brain. Despite the fact that MRI is routinely used to obtain data for neuroscience research, there has been no widely adopted standard for organizing and describing the data collected in an imaging experiment....

  3. Microwave Imaging of Human Forearms: Pilot Study and Image Enhancement

    Directory of Open Access Journals (Sweden)

    Colin Gilmore

    2013-01-01

    Full Text Available We present a pilot study using a microwave tomography system in which we image the forearms of 5 adult male and female volunteers between the ages of 30 and 48. Microwave scattering data were collected at 0.8 to 1.2 GHz with 24 transmitting and receiving antennas located in a matching fluid of deionized water and table salt. Inversion of the microwave data was performed with a balanced version of the multiplicative-regularized contrast source inversion algorithm formulated using the finite-element method (FEM-CSI. T1-weighted MRI images of each volunteer’s forearm were also collected in the same plane as the microwave scattering experiment. Initial “blind” imaging results from the utilized inversion algorithm show that the image quality is dependent on the thickness of the arm’s peripheral adipose tissue layer; thicker layers of adipose tissue lead to poorer overall image quality. Due to the exible nature of the FEM-CSI algorithm used, prior information can be readily incorporated into the microwave imaging inversion process. We show that by introducing prior information into the FEM-CSI algorithm the internal anatomical features of all the arms are resolved, significantly improving the images. The prior information was estimated manually from the blind inversions using an ad hoc procedure.

  4. Stereo Vision-Based High Dynamic Range Imaging Using Differently-Exposed Image Pair

    Directory of Open Access Journals (Sweden)

    Won-Jae Park

    2017-06-01

    Full Text Available In this paper, a high dynamic range (HDR imaging method based on the stereo vision system is presented. The proposed method uses differently exposed low dynamic range (LDR images captured from a stereo camera. The stereo LDR images are first converted to initial stereo HDR images using the inverse camera response function estimated from the LDR images. However, due to the limited dynamic range of the stereo LDR camera, the radiance values in under/over-exposed regions of the initial main-view (MV HDR image can be lost. To restore these radiance values, the proposed stereo matching and hole-filling algorithms are applied to the stereo HDR images. Specifically, the auxiliary-view (AV HDR image is warped by using the estimated disparity between initial the stereo HDR images and then effective hole-filling is applied to the warped AV HDR image. To reconstruct the final MV HDR, the warped and hole-filled AV HDR image is fused with the initial MV HDR image using the weight map. The experimental results demonstrate objectively and subjectively that the proposed stereo HDR imaging method provides better performance compared to the conventional method.

  5. Radiological imaging features and clinicopathological correlation of hemosiderotic fibrolipomatous tumor: experience in a single tertiary cancer center

    Energy Technology Data Exchange (ETDEWEB)

    O' Driscoll, Dearbhail; Athanasian, Edward; Hameed, Meera; Hwang, Sinchun [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2015-05-01

    To determine the imaging features of hemosiderotic fibrolipomatous tumor (HFLT), which has a propensity towards local recurrence and the potential to transform into myxoinflammatory fibroblastic sarcoma (MIFS). The study included 8 patients with a diagnosis of HFLT and imaging at a tertiary cancer center. Imaging studies included radiographs (n = 2), ultrasound (n = 3), and MRI (n = 16). Imaging features were evaluated including location, calcification, sonographic echogenicity, vascular flow, size, border, signal characteristics, contrast enhancement, and blooming on MRI. The HFLT was located in the ankle/foot in 4 out of 8 and was subcutaneous in 8 out of 8, ranging in size from 2 to 18 cm. Histology at initial diagnosis was HFLT in 5 out of 8 and HFLT with MIFS in 3 out of 8. None was calcified on radiography. On ultrasound 2 out of 3 were heterogeneously echogenic with ≥10 foci of vascular flow. Two out of 8 patients had MRI only at local recurrence. The tumor border was infiltrative in 4 out of 6 at initial diagnosis and in 2 patients with MRI at recurrence only. Fat and septae were present in 7 out of 8 at initial diagnosis and at recurrence. Signal intensity was iso-/hypointense to muscle on T1-weighted sequences in more than two thirds of the tumor in 4 out of 7 and hyperintense to muscle in at least one third of the tumor on fluid-sensitive sequences in 6 out of 8. Contrast enhancement was heterogeneous in 7 out of 7; blooming in two thirds of the tumor on gradient-echo sequence MRI indicated hemorrhage. The HFLT commonly presents as a mass with an infiltrative border, interspersed fat and septations at initial diagnosis and local recurrence on MRI regardless of histology of HFLT alone or with MIFS. Hemosiderin deposits may be detected as blooming on gradient-echo sequences. (orig.)

  6. Meniscal tear. Diagnostic errors in MR imaging

    International Nuclear Information System (INIS)

    Barrera, M. C.; Recondo, J. A.; Gervas, C.; Fernandez, E.; Villanua, J. A.M.; Salvador, E.

    2003-01-01

    To analyze diagnostic discrepancies found between magnetic resonance (MR) and arthroscopy, and the determine the reasons that they occur. Two-hundred and forty-eight MR knee explorations were retrospectively checked. Forty of these showed diagnostic discrepancies between MR and arthroscopy. Two radiologists independently re-analyzed the images from 29 of the 40 studies without knowing which diagnosis had resulted from which of the two techniques. Their interpretations were correlated with the initial MR diagnosis, MR images and arthroscopic results. Initial errors in MR imaging were classified as either unavoidable, interpretive, or secondary to equivocal findings. Eleven MR examinations could not be checked since their corresponding imaging results could not be located. Of 34 errors found in the original diagnoses, 12 (35.5%)were classified as unavoidable, 14 (41.2%) as interpretative and 8 (23.5%) as secondary to equivocal findings. 41.2% of the errors were avoided in the retrospective study probably due to our department having greater experience in interpreting MR images, 25.5% were unavailable even in the retrospective study. A small percentage of diagnostic errors were due to the presence of subtle equivocal findings. (Author) 15 refs

  7. The determination of parameters of shower initiated in imaging calorimeter by electrons and protons

    International Nuclear Information System (INIS)

    Borisov, S.V.; Voronov, S.A.; Karelin, A.V.; Koldobskij, S.A.; Runtso, M.F.

    2010-01-01

    In this work the report on several methods of shower axis reconstruction and methods of search for the starting point of the shower are presented. They were developed for 'thin' sampling imaging calorimeters. For this purpose we used a Monte-Carlo simulation of interaction of electrons and protons with a silicon-tungsten calorimeter of PAMELA satellite-borne experiment. After some adaptation, these methods could be applied for different types of calorimeters

  8. Student Experiences: the 2013 Cascadia Initiative Expedition Team's Apply to Sail Program

    Science.gov (United States)

    Mejia, H.; Hooft, E. E.; Fattaruso, L.

    2013-12-01

    During the summer of 2013, the Cascadia Initiative Expedition Team led six oceanographic expeditions to recover and redeploy ocean bottom seismometers (OBSs) across the Cascadia subduction zone and Juan de Fuca plate. The Cascadia Initiative (CI) is an onshore/offshore seismic and geodetic experiment to study questions ranging from megathrust earthquakes to volcanic arc structure to the formation, deformation and hydration of the Juan de Fuca and Gorda plates with the overarching goal of understanding the entire subduction zone system. The Cascadia Initiative Expedition Team is a team of scientists charged with leading the oceanographic expeditions to deploy and recover CI OBSs and developing the associated Education and Outreach effort. Students and early career scientists were encouraged to apply to join the cruises via the Cascadia Initiative Expedition Team's Apply to Sail Program. The goal of this call for open participation was to help expand the user base of OBS data by providing opportunities for students and scientists to directly experience at-sea acquisition of OBS data. Participants were required to have a strong interest in learning field techniques, be willing to work long hours at sea assisting in OBS deployment, recovery and preliminary data processing and have an interest in working with the data collected. In total, there were 51 applicants to the Apply to Sail Program from the US and 4 other countries; 21 graduate students as well as a few undergraduate students, postdocs and young scientists from the US and Canada were chosen to join the crew. The cruises lasted from 6 to 14 days in length. OBS retrievals comprised the three first legs, of which the first two were aboard the Research Vessel Oceanus. During each of the retrievals, multiple acoustic signals were sent while the vessel completed a semi-circle around the OBS to accurately determine its position, a final signal was sent to drop the seismometer's anchor, and finally the ship and crew

  9. A Quick and Affine Invariance Matching Method for Oblique Images

    Directory of Open Access Journals (Sweden)

    XIAO Xiongwu

    2015-04-01

    Full Text Available This paper proposed a quick, affine invariance matching method for oblique images. It calculated the initial affine matrix by making full use of the two estimated camera axis orientation parameters of an oblique image, then recovered the oblique image to a rectified image by doing the inverse affine transform, and left over by the SIFT method. We used the nearest neighbor distance ratio(NNDR, normalized cross correlation(NCC measure constraints and consistency check to get the coarse matches, then used RANSAC method to calculate the fundamental matrix and the homography matrix. And we got the matches that they were interior points when calculating the homography matrix, then calculated the average value of the matches' principal direction differences. During the matching process, we got the initial matching features by the nearest neighbor(NN matching strategy, then used the epipolar constrains, homography constrains, NCC measure constrains and consistency check of the initial matches' principal direction differences with the calculated average value of the interior matches' principal direction differences to eliminate false matches. Experiments conducted on three pairs of typical oblique images demonstrate that our method takes about the same time as SIFT to match a pair of oblique images with a plenty of corresponding points distributed evenly and an extremely low mismatching rate.

  10. P/Halley the model comet, in view of the imaging experiment aboard the VEGA spacecraft

    International Nuclear Information System (INIS)

    Szegoe, K.

    1989-07-01

    In this paper those results of the VEGA imaging experiments are summarized which probably have general validity for any comet. Shape, size, surface structure, jet activity, rotation patterns are considered in this respect. It is pointed out that imaging data provide indispensable information to the understanding of cometary activity. (author) 27 refs

  11. A multi-offset vertical profiling (VSP) experiment for anisotropy analysis and imaging

    Energy Technology Data Exchange (ETDEWEB)

    Grech, G. K.; Lawton, D. [Calgary Univ., AB (Canada)

    2000-09-01

    Vertical seismic profiling (VSP) and surface seismic data are used to image and locate hydrocarbon targets in the subsurface, hence the importance of assessing which formations exhibit seismic velocity anisotropy and quantify their parameters for use during seismic imaging. The purpose of the experiments described in this paper was to determine whether the multiple dipping thin shale beds overlying the target area in the Rocky Mountain Foothills in southern Alberta exhibit seismic velocity anisotropy and if so, how this phenomenon affects the image of the underlying target. Traveltime inversion of the first arrival data from the multi-offset VSP in the study area has revealed that the Cretaceous shales exhibit velocity anisotropy of about 10 degrees. For a target depth of 3000 m and moderate dips of 30 to 50 degrees in the anisotropic overburden, it would be reasonable to expect a lateral shift in the imaged location of the target of up to 300 m in the up-direction of overlying bedding. 8 refs., 9 figs.

  12. Non-enhanced 3D MR angiography of the lower extremity using ECG-gated TSE imaging with non-selective refocusing pulses. Initial experience

    International Nuclear Information System (INIS)

    Lanzman, R.S.; Blondin, D.; Orzechowski, D.; Scherer, A.; Moedder, U.; Kroepil, P.; Godehardt, E.

    2010-01-01

    Purpose: To evaluate non-enhanced 3D MR angiography using turbo spin echo (TSE) imaging with non-selective refocusing pulses (NATIVE SPACE MRA) for the visualization of the arteries of the lower extremity. Materials and Methods: Three-station imaging (iliac arteries, femoral arteries, arteries of the lower leg) was performed in 8 healthy volunteers and 3 patients with peripheral artery disease (PAD) using a 1.5 T MR scanner. In 8 healthy volunteers, 4 different acquisition schemes were performed with the following imaging parameters: S 1: acquisition with every heartbeat (RR = 1), spoiler gradient of 25 % (SG = 25 %); S 2: RR = 1, SG = 0 %; S 3: RR = 2, SG = 25 %; S 4: RR = 2, SG = 0 %. The subjective image quality on a 4-point-scale (4 = excellent to 1 = not diagnostic) and relative SNR were assessed. In 3 patients with peripheral artery disease (PAD), SPACE MRA was performed for assessment of stenosis. Results: The mean subjective image quality was significantly lower for the iliac arteries compared to the femoral arteries and arteries of the lower leg (p < 0.0001). The subjective image quality for acquisition scheme S 1 was significantly lower than the image quality for S 3 and S 4 for the iliac arteries (p < 0.01), while the subjective image quality for acquisition scheme S 2 was significantly lower than S 3 and S 4 for the femoral arteries and the arteries of the lower leg (p < 0.01). The relative SNR was significantly higher for acquisition schemes S 3 and S 4 as compared to S 1 and S 2 (p < 0.0001) for all regions. SPACE MRA disclosed 7 significant stenoses in 3 PAD patients. Conclusion: ECG-gated SPACE MRA is a promising imaging technique for non-enhanced assessment of the arteries of the lower extremity. (orig.)

  13. Imaging radar observations of Farley Buneman waves during the JOULE II experiment

    Directory of Open Access Journals (Sweden)

    D. L. Hysell

    2008-07-01

    Full Text Available Vector electric fields and associated E×B drifts measured by a sounding rocket in the auroral zone during the NASA JOULE II experiment in January 2007, are compared with coherent scatter spectra measured by a 30 MHz radar imager in a common volume. Radar imaging permits precise collocation of the spectra with the background electric field. The Doppler shifts and spectral widths appear to be governed by the cosine and sine of the convection flow angle, respectively, and also proportional to the presumptive ion acoustic speed. The neutral wind also contributes to the Doppler shifts. These findings are consistent with those from the JOULE I experiment and also with recent numerical simulations of Farley Buneman waves and instabilities carried out by Oppenheim et al. (2008. Simple linear analysis of the waves offers some insights into the spectral moments. A formula relating the spectral width to the flow angle, ion acoustic speed, and other ionospheric parameters is derived.

  14. Image compression of bone images

    International Nuclear Information System (INIS)

    Hayrapetian, A.; Kangarloo, H.; Chan, K.K.; Ho, B.; Huang, H.K.

    1989-01-01

    This paper reports a receiver operating characteristic (ROC) experiment conducted to compare the diagnostic performance of a compressed bone image with the original. The compression was done on custom hardware that implements an algorithm based on full-frame cosine transform. The compression ratio in this study is approximately 10:1, which was decided after a pilot experiment. The image set consisted of 45 hand images, including normal images and images containing osteomalacia and osteitis fibrosa. Each image was digitized with a laser film scanner to 2,048 x 2,048 x 8 bits. Six observers, all board-certified radiologists, participated in the experiment. For each ROC session, an independent ROC curve was constructed and the area under that curve calculated. The image set was randomized for each session, as was the order for viewing the original and reconstructed images. Analysis of variance was used to analyze the data and derive statistically significant results. The preliminary results indicate that the diagnostic quality of the reconstructed image is comparable to that of the original image

  15. Initial experience of using an active beam delivery technique at PSI

    International Nuclear Information System (INIS)

    Pedroni, E.; Boehringer, T.; Coray, A.; Egger, E.; Grossmann, M.; Lin Shixiong; Lomax, A.; Goitein, G.; Roser, W.; Schaffner, B.

    1999-01-01

    At PSI a new proton therapy facility has been assembled and commissioned. The major features of the facility are the spot scanning technique and the very compact gantry. The operation of the facility was started in 1997 and the feasibility of the spot scanning technique has been demonstrated in practice with patient treatments. In this report we discuss the usual initial difficulties encountered in the commissioning of a new technology, the very positive preliminary experience with the system and the optimistic expectations for the future. The long range goal of this project is to parallel the recent developments regarding inverse planning for photons with a similar advanced technology optimized for a proton beam. (orig.)

  16. Functional imaging in differentiating bronchial masses: an initial experience with a combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan.

    Science.gov (United States)

    Kumar, Arvind; Jindal, Tarun; Dutta, Roman; Kumar, Rakesh

    2009-10-01

    To evaluate the role of combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in differentiating bronchial tumors observed in contrast enhanced computed tomography scan of chest. Prospective observational study. Place of study: All India Institute of Medical Sciences, New Delhi, India. 7 patients with bronchial mass detected in computed tomography scan of the chest were included in this study. All patients underwent (18)F-FDG PET-CT scan, (68)Ga DOTA-TOC PET-CT scan and fiberoptic bronchoscope guided biopsy followed by definitive surgical excision. The results of functional imaging studies were analyzed and the results are correlated with the final histopathology of the tumor. Histopathological examination of 7 bronchial masses revealed carcinoid tumors (2 typical, 1 atypical), inflammatory myofibroblastic tumor (1), mucoepidermoid carcinoma (1), hamartoma (1), and synovial cell sarcoma (1). The typical carcinoids had mild (18)F-FDG uptake and high (68)Ga DOTA-TOC uptake. Atypical carcinoid had moderate uptake of (18)F-FDG and high (68)Ga DOTA-TOC uptake. Inflammatory myofibroblastic tumor showed high uptake of (18)F-FDG and no uptake of (68)Ga DOTA-TOC. Mucoepidermoid carcinoma showed mild (18)F-FDG uptake and no (68)Ga DOTA-TOC uptake. Hamartoma showed no uptake on either scans. Synovial cell sarcoma showed moderate (18)F-FDG uptake and mild focal (68)Ga DOTA-TOC uptake. This initial experience with the combined use of (18)F-FDG and (68)Ga DOTA-TOC PET-CT scan reveals different uptake patterns in various bronchial tumors. Bronchoscopic biopsy will continue to be the gold standard; however, the interesting observations made in this study merits further evaluation of the utility of the combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in larger number of patients with bronchial masses.

  17. Unenhanced multidetector CT (CT KUB) in the initial imaging of suspected acute renal colic: evaluating a new service

    International Nuclear Information System (INIS)

    Chowdhury, F.U.; Kotwal, S.; Raghunathan, G.; Wah, T.M.; Joyce, A.; Irving, H.C.

    2007-01-01

    Aim: To evaluate a new imaging pathway for the investigation of patients presenting with suspected acute renal colic. Materials and methods: A retrospective review of 500 consecutive cases of suspected acute renal colic was undertaken to evaluate the initial results of a new imaging pathway introduced at our institution, which completely replaced the intravenous urogram (IVU) with unenhanced multidetector CT (CT KUB). Results: The positive rate for urolithiasis was 44% (221/500), the negative rate 46% (229/500) and the rate of other significant findings was 12% (59/500). Female patients had a low positive rate compared with male patients (27.5 versus 57.5%; p < 0.001). Urological intervention was required in 28% (61/221) and these patients had a larger average stone size (6.6 versus 3.7 mm; p < 0.001) and the stone was located more proximally. Out-of-hours imaging was performed in 37% (186/500), and these patients had a higher positive rate (52 versus 40%; p < 0.001). Other findings included a wide range of acute non-urological conditions. Conclusion: The feasibility of replacing the acute IVU with CT KUB in the initial assessment of suspected acute renal colic was demonstrated in the present study. The technique enables rapid diagnosis of urolithiasis, stratification of patients likely to proceed to urological intervention, and prompt diagnosis of a variety of other acute pathological conditions

  18. Inelastic neutron scattering experiments with the monochromatic imaging mode of the RITA-II spectrometer

    International Nuclear Information System (INIS)

    Bahl, C.R.H.; Lefmann, K.; Abrahamsen, A.B.; Ronnow, H.M.; Saxild, F.; Jensen, T.B.S.; Udby, L.; Andersen, N.H.; Christensen, N.B.; Jakobsen, H.S.; Larsen, T.; Haefliger, P.S.; Streule, S.; Niedermayer, Ch.

    2006-01-01

    Recently a monochromatic multiple data taking mode has been demonstrated for diffraction experiments using a RITA type cold neutron spectrometer with a multi-bladed analyser and a position-sensitive detector. Here, we show how this mode can be used in combination with a flexible radial collimator to perform real inelastic neutron scattering experiments. We present the results from inelastic powder, single crystal dispersion and single crystal constant energy mapping experiments. The advantages and complications of performing these experiments are discussed along with a comparison between the imaging mode and the traditional monochromatic focussing mode

  19. Inelastic neutron scattering experiments with the monochromatic imaging mode of the RITA-II spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bahl, C.R.H. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark) and Department of Physics, Technical University of Denmark, DK-2800 Lyngby (Denmark)]. E-mail: christian.bahl@risoe.dk; Lefmann, K. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)]. E-mail: kim.lefmann@risoe.dk; Abrahamsen, A.B. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Ronnow, H.M. [Laboratory for Neutron Scattering, Paul Scherrer Institute, CH-5232 Villigen (Switzerland); Saxild, F. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Jensen, T.B.S. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Udby, L. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Andersen, N.H. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Christensen, N.B. [Department of Materials Research, Riso National Laboratory, Building 227, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Laboratory for Neutron Scattering, Paul Scherrer Institute, CH-5232 Villigen (Switzerland); Jakobsen, H.S. [Niels Bohr Institute for Astronomy, Physics and Geophysics, University of Copenhagen, DK-2100 Copenhagen (Denmark); Larsen, T. [Niels Bohr Institute for Astronomy, Physics and Geophysics, University of Copenhagen, DK-2100 Copenhagen (Denmark); Haefliger, P.S. [Laboratory for Neutron Scattering, Paul Scherrer Institute, CH-5232 Villigen (Switzerland); Streule, S.; Niedermayer, Ch. [Laboratory for Neutron Scattering, Paul Scherrer Institute, CH-5232 Villigen (Switzerland)

    2006-05-15

    Recently a monochromatic multiple data taking mode has been demonstrated for diffraction experiments using a RITA type cold neutron spectrometer with a multi-bladed analyser and a position-sensitive detector. Here, we show how this mode can be used in combination with a flexible radial collimator to perform real inelastic neutron scattering experiments. We present the results from inelastic powder, single crystal dispersion and single crystal constant energy mapping experiments. The advantages and complications of performing these experiments are discussed along with a comparison between the imaging mode and the traditional monochromatic focussing mode.

  20. Predicting Retear after Repair of Full-Thickness Rotator Cuff Tear: Two-Point Dixon MR Imaging Quantification of Fatty Muscle Degeneration-Initial Experience with 1-year Follow-up.

    Science.gov (United States)

    Nozaki, Taiki; Tasaki, Atsushi; Horiuchi, Saya; Ochi, Junko; Starkey, Jay; Hara, Takeshi; Saida, Yukihisa; Yoshioka, Hiroshi

    2016-08-01

    Purpose To determine the degree of preoperative fatty degeneration within muscles, postoperative longitudinal changes in fatty degeneration, and differences in fatty degeneration between patients with full-thickness supraspinatus tears who do and those who do not experience a retear after surgery. Materials and Methods This prospective study had institutional review board approval and was conducted in accordance with the Committee for Human Research. Informed consent was obtained. Fifty patients with full-thickness supraspinatus tears (18 men, 32 women; mean age, 67.0 years ± 8.0; age range, 41-91 years) were recruited. The degrees of preoperative and postoperative fatty degeneration were quantified by using a two-point Dixon magnetic resonance (MR) imaging sequence; two radiologists measured the mean signal intensity on in-phase [S(In)] and fat [S(Fat)] images. Estimates of fatty degeneration were calculated with "fat fraction" values by using the formula S(Fat)/S(In) within the supraspinatus, infraspinatus, and subscapularis muscles at baseline preoperative and at postoperative 1-year follow-up MR imaging. Preoperative fat fractions in the failed-repair group and the intact-repair group were compared by using the Mann-Whitney U test. Results The preoperative fat fractions in the supraspinatus muscle were significantly higher in the failed-repair group than in the intact-repair group (37.0% vs 19.5%, P muscle tended to progress at 1 year postoperatively in only the failed-repair group. Conclusion MR imaging quantification of preoperative fat fractions by using a two-point Dixon sequence within the rotator cuff muscles may be a viable method for predicting postoperative retear. (©) RSNA, 2016.

  1. The Lyman Alpha Imaging-Monitor Experiment (LAIME) for TESIS/CORONAS-PHOTON

    Science.gov (United States)

    Damé, L.; Koutchmy, S.; Kuzin, S.; Lamy, P.; Malherbe, J.-M.; Noëns, J.-C.

    LAIME the Lyman Alpha Imaging-Monitor Experiment is a remarkably simple no mechanisms and compact 100x100x400 mm full Sun imager to be flown with TESIS on the CORONAS-PHOTON mission launch expected before mid-2008 As such it will be the only true chromospheric imager to be flown in the next years supporting TESIS EUV-XUV imaging SDO and the Belgian LYRA Lyman Alpha flux monitor on the ESA PROBA-2 microsatellite launch expected in September 2007 We will give a short description of this unique O60 mm aperture imaging telescope dedicated to the investigating of the magnetic sources of solar variability in the UV and chromospheric and coronal disruptive events rapid waves Moreton waves disparitions brusques of prominences filaments eruptions and CMEs onset The resolution pixel is 2 7 arcsec the field of view 1 4 solar radius and the acquisition cadence could be as high as 1 image minute The back thinned E2V CCD in the focal plane is using frame transfer to avoid shutter and mechanisms Further more the double Lyman Alpha filtering allows a 40 AA FWHM bandwidth and excellent rejection yet providing a vacuum seal design of the telescope MgF2 entrance window Structural stability of the telescope focal length 1 m is preserved by a 4-INVAR bars design with Aluminium compensation in a large pm 10 o around 20 o

  2. Optimized curve design for image analysis using localized geodesic distance transformations

    Science.gov (United States)

    Braithwaite, Billy; Niska, Harri; Pöllänen, Irene; Ikonen, Tiia; Haataja, Keijo; Toivanen, Pekka; Tolonen, Teemu

    2015-03-01

    We consider geodesic distance transformations for digital images. Given a M × N digital image, a distance image is produced by evaluating local pixel distances. Distance Transformation on Curved Space (DTOCS) evaluates shortest geodesics of a given pixel neighborhood by evaluating the height displacements between pixels. In this paper, we propose an optimization framework for geodesic distance transformations in a pattern recognition scheme, yielding more accurate machine learning based image analysis, exemplifying initial experiments using complex breast cancer images. Furthermore, we will outline future research work, which will complete the research work done for this paper.

  3. Functional brain imaging with I123-amphetamine. First experience in the Netherlands

    NARCIS (Netherlands)

    de Bruïne, J. F.; van Royen, E. A.; van Weeren, F.; vd Weel, F. A.; Reiffers, S.; Verbeeten, B. W.; Krens, H.; Hijdra, A.; Limburg, M.

    1986-01-01

    Single Photon Emission Computed Tomography (SPECT) has been used in the last five years as a method for cerebral bloodflow imaging, especially in cerebral infarction. In this study the first experiences in the Netherlands are presented. In 57.6% of our patients lesions, defined by SPECT were larger

  4. Associations between Forced Sexual Initiation, HIV Status, Sexual Risk Behavior, Life Stressors, and Coping Strategies among Adolescents in Nigeria.

    Directory of Open Access Journals (Sweden)

    Morenike Oluwatoyin Folayan

    Full Text Available Some individuals experience their first sexual intercourse through physically forced sex, which affects the way they experience and cope with stress. We examined differences in sexual risk behavior, experience of stressors, and use of stress-coping strategies among adolescents in Nigeria based on their history of forced sexual initiation and HIV status.We analyzed data from 436 sexually active 10-19-year-old adolescents recruited through a population-based survey from 12 Nigerian states. Using Lazarus and Folkman's conceptual framework of stress and coping, we assessed if adolescents who reported forced sexual initiation were more likely to report HIV sexual risk practices, to report as stressors events related to social expectations, medical care and body images, and loss and grief, and to use more avoidance than adaptive coping strategies to manage stress. We also assessed if HIV status affected experience of stressors and use of coping strategies.Eighty-one adolescents (18.6% reported a history of forced sexual initiation; these participants were significantly more likely to report anal sex practices (OR: 5.04; 95% CI: 2.14-11.87, and transactional sex (OR: 2.80; 95% CI: 1.56-4.95. Adolescents with no history of forced sexual initiation were more likely to identify as stressors, life events related to social expectations (OR: 1.03; 95% CI: 0.96-1.11 and loss and grief (OR: 1.34; 95% CI: 0.73-2.65, but not those related to medical care and body images (OR: 0.63; 95% CI: 0.34-1.18. They were also more likely to use adaptive responses (OR: 1.48; 95% CI: 0.62-3.50 than avoidance responses (OR: 0.90; 95% CI: 0.49-1.64 to cope with stress, though these differences were not significant. More adolescents with a history of forced sexual initiation who were HIV positive identified as stressors, life events related to medical care and body images (p = 0.03 and loss and grief (p = 0.009. Adolescents reporting forced sexual initiation and HIV

  5. High-speed infrared imaging for material characterization in experimental mechanics experiments

    Science.gov (United States)

    Gagnon, Marc-André; Marcotte, Frédérick; Lagueux, Philippe; Farley, Vincent; Guyot, Éric; Morton, Vince

    2017-10-01

    Heat transfers are involved in many phenomena such as friction, tensile stress, shear stress and material rupture. Among the challenges encountered during the characterization of such thermal patterns is the need for both high spatial and temporal resolution. Infrared imaging provides information about surface temperature that can be attributed to the stress response of the material and breaking of chemical bounds. In order to illustrate this concept, tensile and shear tests were carried out on steel, aluminum and carbon fiber composite materials and monitored using high-speed (Telops FASTM2K) and high-definition (Telops HD-IR) infrared imaging. Results from split-Hopkinson experiments carried out on a polymer material at high strain-rate are also presented. The results illustrate how high-speed and high-definition infrared imaging in the midwave infrared (MWIR, 3 - 5 μm) spectral range can provide detailed information about the thermal properties of materials undergoing mechanical testing.

  6. 18F-DOPA PET and enhanced CT imaging for congenital hyperinsulinism: initial UK experience from a technologist's perspective.

    Science.gov (United States)

    Meintjes, Marguerite; Endozo, Raymond; Dickson, John; Erlandsson, Kjel; Hussain, Khalid; Townsend, Caroline; Menezes, Leon; Bomanji, Jamshed

    2013-06-01

    Congenital hyperinsulinism (CHI) is the most common cause of persistent hypoglycaemia in infants and children. Histologically, there are two subgroups, diffuse and focal. The aim of this study was to evaluate the accuracy of (18)F-fluoro-L-dihydroxyphenylalanine ((18)F-DOPA) PET/computed tomography (CT) and contrast-enhanced CT in distinguishing between focal and diffuse lesions in infants with CHI who are unresponsive to medical therapy. In addition, this paper describes the detailed protocol used for imaging and analysis of (18)F-DOPA PET/CT images in our clinical practice. Twenty-two (18)F-DOPA PET/CT and contrast-enhanced CT imaging studies were carried out on 18 consecutive patients (nine boys and nine girls) with CHI (median age, 2 years and 1 month; range, 1-84 months) who had positive dominant ABCC8 mutation genetic results or negative ABCC8/t results but did not respond to first-line medical therapy with high-dose diazoxide. (18)F-DOPA was produced by the cyclotron unit of Woolfson Molecular Imaging Centre, Manchester, and transported to our centre in central London after synthesis and implementation of quality control measures. (18)F-DOPA was administered intravenously at a dose of 4 MBq/kg, and iodine contrast medium was injected intravenously at a dose of 1.5 ml/kg. Single bed position PET/CT images of the pancreas were acquired under light sedation with oral chloral hydrate. Four PET dynamic data acquisition scans were taken 20, 40, 50 and 60 min after injection for a duration of 10 min each. The results were assessed by visual interpretation and quantitative measurements of standardized uptake values (SUVs) in the head, body, and tail of the pancreas. Of the 18 patients, 13 showed diffuse and five showed focal (18)F-DOPA PET pancreatic uptake. Three regions of interest were drawn over the head, body and tail of the pancreas to calculate the SUV(max). Using the formula - highest SUV(max)/next highest SUV(max) - a ratio was calculated. Five patients had

  7. Measuring health systems strength and its impact: experiences from the African Health Initiative.

    Science.gov (United States)

    Sherr, Kenneth; Fernandes, Quinhas; Kanté, Almamy M; Bawah, Ayaga; Condo, Jeanine; Mutale, Wilbroad

    2017-12-21

    Health systems are essential platforms for accessible, quality health services, and population health improvements. Global health initiatives have dramatically increased health resources; however, funding to strengthen health systems has not increased commensurately, partially due to concerns about health system complexity and evidence gaps demonstrating health outcome improvements. In 2009, the African Health Initiative of the Doris Duke Charitable Foundation began supporting Population Health Implementation and Training Partnership projects in five sub-Saharan African countries (Ghana, Mozambique, Rwanda, Tanzania, and Zambia) to catalyze significant advances in strengthening health systems. This manuscript reflects on the experience of establishing an evaluation framework to measure health systems strength, and associate measures with health outcomes, as part of this Initiative. Using the World Health Organization's health systems building block framework, the Partnerships present novel approaches to measure health systems building blocks and summarize data across and within building blocks to facilitate analytic procedures. Three Partnerships developed summary measures spanning the building blocks using principal component analysis (Ghana and Tanzania) or the balanced scorecard (Zambia). Other Partnerships developed summary measures to simplify multiple indicators within individual building blocks, including health information systems (Mozambique), and service delivery (Rwanda). At the end of the project intervention period, one to two key informants from each Partnership's leadership team were asked to list - in rank order - the importance of the six building blocks in relation to their intervention. Though there were differences across Partnerships, service delivery and information systems were reported to be the most common focus of interventions, followed by health workforce and leadership and governance. Medical products, vaccines and technologies, and

  8. Voxel-based Monte Carlo simulation of X-ray imaging and spectroscopy experiments

    International Nuclear Information System (INIS)

    Bottigli, U.; Brunetti, A.; Golosio, B.; Oliva, P.; Stumbo, S.; Vincze, L.; Randaccio, P.; Bleuet, P.; Simionovici, A.; Somogyi, A.

    2004-01-01

    A Monte Carlo code for the simulation of X-ray imaging and spectroscopy experiments in heterogeneous samples is presented. The energy spectrum, polarization and profile of the incident beam can be defined so that X-ray tube systems as well as synchrotron sources can be simulated. The sample is modeled as a 3D regular grid. The chemical composition and density is given at each point of the grid. Photoelectric absorption, fluorescent emission, elastic and inelastic scattering are included in the simulation. The core of the simulation is a fast routine for the calculation of the path lengths of the photon trajectory intersections with the grid voxels. The voxel representation is particularly useful for samples that cannot be well described by a small set of polyhedra. This is the case of most naturally occurring samples. In such cases, voxel-based simulations are much less expensive in terms of computational cost than simulations on a polygonal representation. The efficient scheme used for calculating the path lengths in the voxels and the use of variance reduction techniques make the code suitable for the detailed simulation of complex experiments on generic samples in a relatively short time. Examples of applications to X-ray imaging and spectroscopy experiments are discussed

  9. Voxel-based Monte Carlo simulation of X-ray imaging and spectroscopy experiments

    Energy Technology Data Exchange (ETDEWEB)

    Bottigli, U. [Istituto di Matematica e Fisica dell' Universita di Sassari, via Vienna 2, 07100, Sassari (Italy); Sezione INFN di Cagliari (Italy); Brunetti, A. [Istituto di Matematica e Fisica dell' Universita di Sassari, via Vienna 2, 07100, Sassari (Italy); Golosio, B. [Istituto di Matematica e Fisica dell' Universita di Sassari, via Vienna 2, 07100, Sassari (Italy) and Sezione INFN di Cagliari (Italy)]. E-mail: golosio@uniss.it; Oliva, P. [Istituto di Matematica e Fisica dell' Universita di Sassari, via Vienna 2, 07100, Sassari (Italy); Stumbo, S. [Istituto di Matematica e Fisica dell' Universita di Sassari, via Vienna 2, 07100, Sassari (Italy); Vincze, L. [Department of Chemistry, University of Antwerp (Belgium); Randaccio, P. [Dipartimento di Fisica dell' Universita di Cagliari and Sezione INFN di Cagliari (Italy); Bleuet, P. [European Synchrotron Radiation Facility, Grenoble (France); Simionovici, A. [European Synchrotron Radiation Facility, Grenoble (France); Somogyi, A. [European Synchrotron Radiation Facility, Grenoble (France)

    2004-10-08

    A Monte Carlo code for the simulation of X-ray imaging and spectroscopy experiments in heterogeneous samples is presented. The energy spectrum, polarization and profile of the incident beam can be defined so that X-ray tube systems as well as synchrotron sources can be simulated. The sample is modeled as a 3D regular grid. The chemical composition and density is given at each point of the grid. Photoelectric absorption, fluorescent emission, elastic and inelastic scattering are included in the simulation. The core of the simulation is a fast routine for the calculation of the path lengths of the photon trajectory intersections with the grid voxels. The voxel representation is particularly useful for samples that cannot be well described by a small set of polyhedra. This is the case of most naturally occurring samples. In such cases, voxel-based simulations are much less expensive in terms of computational cost than simulations on a polygonal representation. The efficient scheme used for calculating the path lengths in the voxels and the use of variance reduction techniques make the code suitable for the detailed simulation of complex experiments on generic samples in a relatively short time. Examples of applications to X-ray imaging and spectroscopy experiments are discussed.

  10. TESIS experiment on EUV imaging spectroscopy of the Sun

    Science.gov (United States)

    Kuzin, S. V.; Bogachev, S. A.; Zhitnik, I. A.; Pertsov, A. A.; Ignatiev, A. P.; Mitrofanov, A. M.; Slemzin, V. A.; Shestov, S. V.; Sukhodrev, N. K.; Bugaenko, O. I.

    2009-03-01

    TESIS is a set of solar imaging instruments in development by the Lebedev Physical Institute of the Russian Academy of Science, to be launched aboard the Russian spacecraft CORONAS-PHOTON in December 2008. The main goal of TESIS is to provide complex observations of solar active phenomena from the transition region to the inner and outer solar corona with high spatial, spectral and temporal resolution in the EUV and Soft X-ray spectral bands. TESIS includes five unique space instruments: the MgXII Imaging Spectroheliometer (MISH) with spherical bent crystal mirror, for observations of the Sun in the monochromatic MgXII 8.42 Å line; the EUV Spectoheliometer (EUSH) with grazing incidence difraction grating, for the registration of the full solar disc in monochromatic lines of the spectral band 280-330 Å; two Full-disk EUV Telescopes (FET) with multilayer mirrors covering the band 130-136 and 290-320 Å; and the Solar EUV Coronagraph (SEC), based on the Ritchey-Chretien scheme, to observe the inner and outer solar corona from 0.2 to 4 solar radii in spectral band 290-320 Å. TESIS experiment will start at the rising phase of the 24th cycle of solar activity. With the advanced capabilities of its instruments, TESIS will help better understand the physics of solar flares and high-energy phenomena and provide new data on parameters of solar plasma in the temperature range 10-10K. This paper gives a brief description of the experiment, its equipment, and its scientific objectives.

  11. In-Situ Visualization Experiments with ParaView Cinema in RAGE

    Energy Technology Data Exchange (ETDEWEB)

    Kares, Robert John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-15

    A previous paper described some numerical experiments performed using the ParaView/Catalyst in-situ visualization infrastructure deployed in the Los Alamos RAGE radiation-hydrodynamics code to produce images from a running large scale 3D ICF simulation. One challenge of the in-situ approach apparent in these experiments was the difficulty of choosing parameters likes isosurface values for the visualizations to be produced from the running simulation without the benefit of prior knowledge of the simulation results and the resultant cost of recomputing in-situ generated images when parameters are chosen suboptimally. A proposed method of addressing this difficulty is to simply render multiple images at runtime with a range of possible parameter values to produce a large database of images and to provide the user with a tool for managing the resulting database of imagery. Recently, ParaView/Catalyst has been extended to include such a capability via the so-called Cinema framework. Here I describe some initial experiments with the first delivery of Cinema and make some recommendations for future extensions of Cinema’s capabilities.

  12. Photometric Calibration of the Barium Cloud Image in a Space Active Experiment: Determining the Release Efficiency

    International Nuclear Information System (INIS)

    Xie Liang-Hai; Li Lei; Wang Jing-Dong; Tao Ran; Cheng Bing-Jun; Zhang Yi-Teng

    2014-01-01

    The barium release experiment is an effective method to explore the near-earth environment and to study all kinds of space physics processes. The first space barium release experiment in China was successfully carried out by a sounding rocket on April 5, 2013. This work is devoted to calculating the release efficiency of the barium release by analyzing the optical image observed during the experiment. First, we present a method to calibrate the images grey value of barium cloud with the reference stars to obtain the radiant fluxes at different moments. Then the release efficiency is obtained by a curve fitting with the theoretical evolution model of barium cloud. The calculated result is basically consistent with the test value on ground

  13. [Initial experience in robot-assisted colorectal surgery in Mexico].

    Science.gov (United States)

    Villanueva-Sáenz, Eduardo; Ramírez-Ramírez, Moisés Marino; Zubieta-O'Farrill, Gregorio; García-Hernández, Luis

    Colorectal surgery has advanced notably since the introduction of the mechanical suture and the minimally invasive approach. Robotic surgery began in order to satisfy the needs of the patient-doctor relationship, and migrated to the area of colorectal surgery. An initial report is presented on the experience of managing colorectal disease using robot-assisted surgery, as well as an analysis of the current role of this platform. A retrospective study was conducted in order to review five patients with colorectal disease operated using a robot-assisted technique over one year in the initial phase of the learning curve. Gender, age, diagnosis and surgical indication, surgery performed, surgical time, conversion, bleeding, post-operative complications, and hospital stay, were analysed and described. A literature review was performed on the role of robotic assisted surgery in colorectal disease and cancer. The study included 5 patients, 3 men and 2 women, with a mean age of 62.2 years. Two of them were low anterior resections with colorectal primary anastomoses, one of them extended with a loop protection ileostomy, a Frykman-Goldberg procedure, and two left hemicolectomies with primary anastomoses. The mean operating time was 6hours and robot-assisted 4hours 20minutes. There were no conversions and the mean hospital stay was 5 days. This technology is currently being used worldwide in different surgical centres because of its advantages that have been clinically demonstrated by various studies. We report the first colorectal surgical cases in Mexico, with promising results. There is enough evidence to support and recommend the use of this technology as a viable and safe option. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  14. Development of Methods for Obtaining Position Image and Chemical Binding Information from Flow Experiments of Porous Media

    Energy Technology Data Exchange (ETDEWEB)

    Haugan, Are

    1998-12-01

    Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computed tomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.

  15. Using Controlled Landslide Initiation Experiments to Test Limit-Equilibrium Analyses of Slope Stability

    Science.gov (United States)

    Reid, M. E.; Iverson, R. M.; Brien, D. L.; Iverson, N. R.; Lahusen, R. G.; Logan, M.

    2004-12-01

    Most studies of landslide initiation employ limit equilibrium analyses of slope stability. Owing to a lack of detailed data, however, few studies have tested limit-equilibrium predictions against physical measurements of slope failure. We have conducted a series of field-scale, highly controlled landslide initiation experiments at the USGS debris-flow flume in Oregon; these experiments provide exceptional data to test limit equilibrium methods. In each of seven experiments, we attempted to induce failure in a 0.65m thick, 2m wide, 6m3 prism of loamy sand placed behind a retaining wall in the 31° sloping flume. We systematically investigated triggering of sliding by groundwater injection, by prolonged moderate-intensity sprinkling, and by bursts of high intensity sprinkling. We also used vibratory compaction to control soil porosity and thereby investigate differences in failure behavior of dense and loose soils. About 50 sensors were monitored at 20 Hz during the experiments, including nests of tiltmeters buried at 7 cm spacing to define subsurface failure geometry, and nests of tensiometers and pore-pressure sensors to define evolving pore-pressure fields. In addition, we performed ancillary laboratory tests to measure soil porosity, shear strength, hydraulic conductivity, and compressibility. In loose soils (porosity of 0.52 to 0.55), abrupt failure typically occurred along the flume bed after substantial soil deformation. In denser soils (porosity of 0.41 to 0.44), gradual failure occurred within the soil prism. All failure surfaces had a maximum length to depth ratio of about 7. In even denser soil (porosity of 0.39), we could not induce failure by sprinkling. The internal friction angle of the soils varied from 28° to 40° with decreasing porosity. We analyzed stability at failure, given the observed pore-pressure conditions just prior to large movement, using a 1-D infinite-slope method and a more complete 2-D Janbu method. Each method provides a static

  16. Initial results from the Wisconsin Spherically Convergent Ion Focus experiment

    International Nuclear Information System (INIS)

    Thorson, T.A.; Durst, R.D.; Fonck, R.J.; Foucher, B.S.; Wainwright, L.P.

    1995-01-01

    The Spherically Convergent Ion Focus (SCIF) is an alternative plasma confinement scheme in which ions are electrostatically confined, accelerated, and concentrated at fusion-relevant energies. This concept has been recently promoted for various near-term applications including waste disposal, particle production, neutron radiography and tomography, plastic explosive detection, materials research, and medical isotope production. The Wisconsin SCIF experiments are designed to evaluate the practicality of the SCIF concept for given applications. In the experiment, a wire globe serves as a simple means of producing the trapping potential well and the ion source consists of a cold, uniform plasma at the edge. Hydrogen ions formed from the background neutral gas are typically accelerated to energies of 5--20 kV, and measured cathode grid currents approach the space-charge limit for concentric spheres. Core size measurements utilize spectrally-filtered CCD camera images of the visible emission from the core region, and the minimal observed core radius of 0.6 cm (HWHM) is within a factor of 2--3 of the theoretical convergence ratio for the device. Neutral particle interactions and potential asymmetries imposed by the grid lead to non-ideal convergence, as evidenced by measured potential asymmetries and core size dependence on cathode grid spacing. Floating probes with 30 kV isolation have allowed unique measurements of the density, electric potential and temperature in the converged core. The ratio of core to edge density is 10--20, which is in good agreement with scaling from radial flux conservation

  17. Tracer tests and image analysis of biological clogging in a two-dimentsional sandbox experiment

    DEFF Research Database (Denmark)

    Kildsgaard, J.; Engesgaard, Peter Knudegaard

    2002-01-01

    A two-dimensional flow experiment on biological clogging was carried out by biostimulating a sandbox packed with sand inoculated with bacteria. Biostimulation. consisted of continuously injecting nutrients (acetate and nitrate). Clogging was visualized by frequently carrying out colored tracer...... experiments using Brilliant Blue. The tracer experiments were recorded with a digital camera and converted to concentration maps using an image-analysis method that revealed in detail the complex spreading pattern surrounding clogged areas. Clogging resulted in a finger-like spreading of the tracer around...

  18. The AGING Initiative experience: a call for sustained support for team science networks.

    Science.gov (United States)

    Garg, Tullika; Anzuoni, Kathryn; Landyn, Valentina; Hajduk, Alexandra; Waring, Stephen; Hanson, Leah R; Whitson, Heather E

    2018-05-18

    Team science, defined as collaborative research efforts that leverage the expertise of diverse disciplines, is recognised as a critical means to address complex healthcare challenges, but the practical implementation of team science can be difficult. Our objective is to describe the barriers, solutions and lessons learned from our team science experience as applied to the complex and growing challenge of multiple chronic conditions (MCC). MCC is the presence of two or more chronic conditions that have a collective adverse effect on health status, function or quality of life, and that require complex healthcare management, decision-making or coordination. Due to the increasing impact on the United States society, MCC research has been identified as a high priority research area by multiple federal agencies. In response to this need, two national research entities, the Healthcare Systems Research Network (HCSRN) and the Claude D. Pepper Older Americans Independence Centers (OAIC), formed the Advancing Geriatrics Infrastructure and Network Growth (AGING) Initiative to build nationwide capacity for MCC team science. This article describes the structure, lessons learned and initial outcomes of the AGING Initiative. We call for funding mechanisms to sustain infrastructures that have demonstrated success in fostering team science and innovation in translating findings to policy change necessary to solve complex problems in healthcare.

  19. Imaging the ocular motor nerves

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Teresa [Department of Radiology, Leiden University Medical Center (Netherlands)], E-mail: T.A.Ferreira@lumc.nl; Verbist, Berit [Department of Radiology, Leiden University Medical Center (Netherlands)], E-mail: B.M.Verbist@lumc.nl; Buchem, Mark van [Department of Radiology, Leiden University Medical Center (Netherlands)], E-mail: M.A.van_Buchem@lumc.nl; Osch, Thijs van [C.J. Gorter for High-Field MRI, Department of Radiology, Leiden University Medical Center (Netherlands)], E-mail: M.J.P.van_Osch@lumc.nl; Webb, Andrew [C.J. Gorter for High-Field MRI, Department of Radiology, Leiden University Medical Center (Netherlands)], E-mail: A.Webb@lumc.nl

    2010-05-15

    The ocular motor nerves (OMNs) comprise the oculomotor, trochlear and the abducens nerves. According to their course, they are divided into four or five anatomic segments: intra-axial, cisternal, cavernous and intra-orbital and, for the abducens nerve, an additional interdural segment. Magnetic resonance imaging is the imaging method of choice in the evaluation of the normal and pathologic ocular motor nerves. CT still plays a limited but important role in the evaluation of the intraosseous portions at the skull base and bony foramina. We describe for each segment of these cranial nerves, the normal anatomy, the most appropriate image sequences and planes, their imaging appearance and pathologic conditions. Magnetic resonance imaging with high magnetic fields is a developing and promising technique. We describe our initial experience with a Phillips 7.0 T MRI scanner in the evaluation of the brainstem segments of the OMNs. As imaging becomes more refined, an understanding of the detailed anatomy is increasingly necessary, as the demand on radiology to diagnose smaller lesions also increases.

  20. Acetazolamide-augmented dynamic BOLD (aczBOLD imaging for assessing cerebrovascular reactivity in chronic steno-occlusive disease of the anterior circulation: An initial experience

    Directory of Open Access Journals (Sweden)

    Junjie Wu

    2017-01-01

    Full Text Available The purpose of this study was to measure cerebrovascular reactivity (CVR in chronic steno-occlusive disease using a novel approach that couples BOLD imaging with acetazolamide (ACZ vasoreactivity (aczBOLD, to evaluate dynamic effects of ACZ on BOLD and to establish the relationship between aczBOLD and dynamic susceptibility contrast (DSC perfusion MRI. Eighteen patients with unilateral chronic steno-occlusive disease of the anterior circulation underwent a 20-min aczBOLD imaging protocol, with ACZ infusion starting at 5 min of scan initiation. AczBOLD reactivity was calculated on a voxel-by-voxel basis to generate CVR maps for subsequent quantitative analyses. Reduced CVR was observed in the diseased vs. the normal hemisphere both by qualitative and quantitative assessment (gray matter (GM: 4.13% ± 1.16% vs. 4.90% ± 0.98%, P = 0.002; white matter (WM: 2.83% ± 1.23% vs. 3.50% ± 0.94%, P = 0.005. In all cases BOLD signal began increasing immediately following ACZ infusion, approaching a plateau at ~8.5 min after infusion, with the tissue volume of reduced augmentation increasing progressively with time, peaking at 2.60 min (time range above 95% of the maximum value: 0–4.43 min for the GM and 1.80 min (time range above 95% of the maximum value: 1.40–3.53 min for the WM. In the diseased hemisphere, aczBOLD CVR significantly correlated with baseline DSC time-to-maximum of the residue function (Tmax (P = 0.008 for the WM and normalized cerebral blood flow (P = 0.003 for the GM, and P = 0.001 for the WM. AczBOLD provides a novel, safe, easily implementable approach to CVR measurement in the routine clinical environments. Further studies can establish quantitative thresholds from aczBOLD towards identification of patients at heightened risk of recurrent ischemia and cognitive decline.

  1. Prevalence of Sexual Experience and Initiation of Sexual Intercourse Among Adolescents, Rakai District, Uganda, 1994-2011

    DEFF Research Database (Denmark)

    Santelli, John S; Song, Xiaoyu; Larsen Holden, Inge Kristine

    2015-01-01

    : Sexual experience was more common among adolescent women than men. The prevalence of sexual experience rose for most age-gender groups after 1994 and then declined after 2002. Factors associated with higher prevalence of sexual experience (without adjustment for other factors) included age, not enrolled......PURPOSE: The purpose of the study was to identify risk factors and time trends for sexual experience and sexual debut in rural Uganda. METHODS: Using population-based, longitudinal data from 15- to 19-year olds in Rakai, Uganda, we examined temporal trends in the prevalence of sexual experience...... and potential risk factors for sexual experience (n = 31,517 person-round observations) using logistic regression. We then identified factors associated with initiation of sex between survey rounds, using Poisson regression to estimate incidence rate ratios (IRR; n = 5,126 person-year observations). RESULTS...

  2. Multi-detector CT knee arthrography - initial experience

    International Nuclear Information System (INIS)

    Thomson, J.M.Z.; Fallon, M.; Breidahl, W.H.

    2002-01-01

    Full text: Traditional plain film arthrography can achieve reasonable accuracy and is an accepted method of investigation of patients with knee pain and possible meniscal tear. Multi-detector CT can potentially provide a more detailed and accurate examination due to its high-resolution crosssectional and multi-planar capabilities. The aim of this study was to assess the accuracy of our technique. All patients who underwent a multi-detector CT knee arthrogram in an initial 8 month period were identified. Initially the referring clinician was contacted. If the patient was referred to an orthopaedic surgeon the outcome of orthopaedic review was recorded using clinical, arthroscopic and / or MRI follow-up of the patient population. One hundred and twelve patients had a Multi-detector CT knee arthrogram performed within and 8 month period. Follow-up information was received in 69.7% of patients. Of these 68.9% had orthopaedic assessment - of which 69.2% underwent a knee arthroscopy.There was total agreement of findings in 67%, agreement of meniscal findings in 67% and chondral findings in 100%. Overall, orthopaedic opinion agreed with CT findings in 76.9%. At this stage, all meniscal tears not described in the initial CT arthrogram report have in retrospect been visible. Multi-detector CT knee arthrography is an accurate and elegant technique for investigation of knee pain, providing information in a format familiar to those reporting knee MRI. There is an initial learning curve. The technique is particularly useful in chondral assessment. It is accurate for meniscal pathology, although caution and recognition of potential pitfalls is required. Copyright (2002) Blackwell Science Pty Ltd

  3. Behaviors study of image registration algorithms in image guided radiation therapy

    International Nuclear Information System (INIS)

    Zou Lian; Hou Qing

    2008-01-01

    Objective: Study the behaviors of image registration algorithms, and analyze the elements which influence the performance of image registrations. Methods: Pre-known corresponding coordinates were appointed for reference image and moving image, and then the influence of region of interest (ROI) selection, transformation function initial parameters and coupled parameter spaces on registration results were studied with a software platform developed in home. Results: Region of interest selection had a manifest influence on registration performance. An improperly chosen ROI resulted in a bad registration. Transformation function initial parameters selection based on pre-known information could improve the accuracy of image registration. Coupled parameter spaces would enhance the dependence of image registration algorithm on ROI selection. Conclusions: It is necessary for clinic IGRT to obtain a ROI selection strategy (depending on specific commercial software) correlated to tumor sites. Three suggestions for image registration technique developers are automatic selection of the initial parameters of transformation function based on pre-known information, developing specific image registration algorithm for specific image feature, and assembling real-time image registration algorithms according to tumor sites selected by software user. (authors)

  4. Optimization of brain PET imaging for a multicentre trial: the French CATI experience.

    Science.gov (United States)

    Habert, Marie-Odile; Marie, Sullivan; Bertin, Hugo; Reynal, Moana; Martini, Jean-Baptiste; Diallo, Mamadou; Kas, Aurélie; Trébossen, Régine

    2016-12-01

    CATI is a French initiative launched in 2010 to handle the neuroimaging of a large cohort of subjects recruited for an Alzheimer's research program called MEMENTO. This paper presents our test protocol and results obtained for the 22 PET centres (overall 13 different scanners) involved in the MEMENTO cohort. We determined acquisition parameters using phantom experiments prior to patient studies, with the aim of optimizing PET quantitative values to the highest possible per site, while reducing, if possible, variability across centres. Jaszczak's and 3D-Hoffman's phantom measurements were used to assess image spatial resolution (ISR), recovery coefficients (RC) in hot and cold spheres, and signal-to-noise ratio (SNR). For each centre, the optimal reconstruction parameters were chosen as those maximizing ISR and RC without a noticeable decrease in SNR. Point-spread-function (PSF) modelling reconstructions were discarded. The three figures of merit extracted from the images reconstructed with optimized parameters and routine schemes were compared, as were volumes of interest ratios extracted from Hoffman acquisitions. The net effect of the 3D-OSEM reconstruction parameter optimization was investigated on a subset of 18 scanners without PSF modelling reconstruction. Compared to the routine parameters of the 22 PET centres, average RC in the two smallest hot and cold spheres and average ISR remained stable or were improved with the optimized reconstruction, at the expense of slight SNR degradation, while the dispersion of values was reduced. For the subset of scanners without PSF modelling, the mean RC of the smallest hot sphere obtained with the optimized reconstruction was significantly higher than with routine reconstruction. The putamen and caudate-to-white matter ratios measured on 3D-Hoffman acquisitions of all centres were also significantly improved by the optimization, while the variance was reduced. This study provides guidelines for optimizing quantitative

  5. 2-D images of the metal-halide lamp obtained by experiment and model

    NARCIS (Netherlands)

    Flikweert, A.J.; Beks, M.L.; Nimalasuriya, T.; Kroesen, G.M.W.; Mullen, van der J.J.A.M.; Stoffels, W.W.

    2008-01-01

    The metal-halide lamp shows color segregation caused by diffusion and convection. Two-dimensional imaging of the arc discharge under varying gravity conditions aids in the understanding of the flow phenomena. In this paper, we show results obtained by experiments and by numerical simulations in

  6. Simultaneous assessment of cerebral blood volume and diffusion heterogeneity using hybrid IVIM and DK MR imaging: initial experience with brain tumors.

    Science.gov (United States)

    Wu, Wen-Chau; Yang, Shun-Chung; Chen, Ya-Fang; Tseng, Han-Min; My, Pei-Chi

    2017-01-01

    To investigate the feasibility of simultaneously assessing cerebral blood volume and diffusion heterogeneity using hybrid diffusion-kurtosis (DK) and intravoxel-incoherent-motion (IVIM) MR imaging. Fifteen healthy volunteers and 30 patients with histologically proven brain tumours (25 WHO grade II-IV gliomas and five metastases) were recruited. On a 3-T system, diffusion-weighted imaging was performed with six b-values ranging from 0 to 1,700 s/mm 2 . Nonlinear least-squares fitting was employed to extract diffusion coefficient (D), diffusion kurtosis coefficient (K, a measure of the degree of non-Gaussian and heterogeneous diffusion) and intravascular volume fraction (f, a measure proportional to cerebral blood volume). Repeated-measures multivariate analysis of variance and receiver operating characteristic analysis were performed to assess the ability of D/K/f in differentiating contrast-enhanced tumour from peritumoral oedema and normal-appearing white matter. Based on our imaging setting (baseline signal-to-noise ratio = 32-128), coefficient of variation was 14-20 % for K, ~6 % for D and 26-44 % for f. The indexes were able to differentiate contrast-enhanced tumour (Wilks' λ = 0.026, p DK IVIM imaging is capable of simultaneously measuring cerebral perfusion and diffusion indexes that together may improve brain tumour diagnosis. • Hybrid DK-IVIM imaging allows simultaneous measurement of K, D and f. • Combined K/D/f better demarcates contrast-enhanced tumour than they do separately. • f correlates better with contrast-leakage-corrected CBV DSC than with uncorrected CBV DSC.

  7. Fast Superpixel Segmentation Algorithm for PolSAR Images

    Directory of Open Access Journals (Sweden)

    Zhang Yue

    2017-10-01

    Full Text Available As a pre-processing technique, superpixel segmentation algorithms should be of high computational efficiency, accurate boundary adherence and regular shape in homogeneous regions. A fast superpixel segmentation algorithm based on Iterative Edge Refinement (IER has shown to be applicable on optical images. However, it is difficult to obtain the ideal results when IER is applied directly to PolSAR images due to the speckle noise and small or slim regions in PolSAR images. To address these problems, in this study, the unstable pixel set is initialized as all the pixels in the PolSAR image instead of the initial grid edge pixels. In the local relabeling of the unstable pixels, the fast revised Wishart distance is utilized instead of the Euclidean distance in CIELAB color space. Then, a post-processing procedure based on dissimilarity measure is empolyed to remove isolated small superpixels as well as to retain the strong point targets. Finally, extensive experiments based on a simulated image and a real-world PolSAR image from Airborne Synthetic Aperture Radar (AirSAR are conducted, showing that the proposed algorithm, compared with three state-of-the-art methods, performs better in terms of several commonly used evaluation criteria with high computational efficiency, accurate boundary adherence, and homogeneous regularity.

  8. Combined preclinical magnetic particle imaging and magnetic resonance imaging. Initial results in mice

    International Nuclear Information System (INIS)

    Kaul, M.G.; Mummert, T.; Jung, C.; Raabe, N.; Ittrich, H.; Adam, G.; Heinen, U.; Reitmeier, A.

    2015-01-01

    Magnetic particle imaging (MPI) is a new radiologic imaging modality. For the first time, a commercial preclinical scanner is installed. The goal of this study was to establish a workflow between MPI and magnetic resonance imaging (MRI) scanners for a complete in vivo examination of a mouse and to generate the first co-registered in vivo MR-MP images. The in vivo examination of five mice were performed on a preclinical MPI scanner and a 7 Tesla preclinical MRI system. MRI measurements were used for anatomical referencing and validation of the injection of superparamagnetic iron oxide (SPIO) particles during a dynamic MPI scan. We extracted MPI data of the injection phase and co-registered it with MRI data. A workflow process for a combined in vivo MRI and MPI examination was established. A successful injection of ferucarbotran was proven in MPI and MRI. MR-MPI co-registration allocated the SPIOs in the inferior vena cava and the heart during and shortly after the injection. The acquisition of preclinical MPI and MRI data is feasible and allows the combined analysis of MR-MPI information.

  9. Combined preclinical magnetic particle imaging and magnetic resonance imaging. Initial results in mice

    Energy Technology Data Exchange (ETDEWEB)

    Kaul, M.G.; Mummert, T.; Jung, C.; Raabe, N.; Ittrich, H.; Adam, G. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Diagnostic and Interventional Radiology; Weber, O. [Philips Medical Systems DMC GmbH, Hamburg (Germany); Heinen, U. [Bruker BioSpin MRI GmbH, Ettlingen (Germany); Reitmeier, A. [Medical Center Hamburg-Eppendorf, Hamburg (Germany). Animal Facility; Knopp, T. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Diagnostic and Interventional Radiology; Hamburg University of Technology, Hamburg (Germany)

    2015-05-15

    Magnetic particle imaging (MPI) is a new radiologic imaging modality. For the first time, a commercial preclinical scanner is installed. The goal of this study was to establish a workflow between MPI and magnetic resonance imaging (MRI) scanners for a complete in vivo examination of a mouse and to generate the first co-registered in vivo MR-MP images. The in vivo examination of five mice were performed on a preclinical MPI scanner and a 7 Tesla preclinical MRI system. MRI measurements were used for anatomical referencing and validation of the injection of superparamagnetic iron oxide (SPIO) particles during a dynamic MPI scan. We extracted MPI data of the injection phase and co-registered it with MRI data. A workflow process for a combined in vivo MRI and MPI examination was established. A successful injection of ferucarbotran was proven in MPI and MRI. MR-MPI co-registration allocated the SPIOs in the inferior vena cava and the heart during and shortly after the injection. The acquisition of preclinical MPI and MRI data is feasible and allows the combined analysis of MR-MPI information.

  10. Active mask segmentation of fluorescence microscope images.

    Science.gov (United States)

    Srinivasa, Gowri; Fickus, Matthew C; Guo, Yusong; Linstedt, Adam D; Kovacević, Jelena

    2009-08-01

    We propose a new active mask algorithm for the segmentation of fluorescence microscope images of punctate patterns. It combines the (a) flexibility offered by active-contour methods, (b) speed offered by multiresolution methods, (c) smoothing offered by multiscale methods, and (d) statistical modeling offered by region-growing methods into a fast and accurate segmentation tool. The framework moves from the idea of the "contour" to that of "inside and outside," or masks, allowing for easy multidimensional segmentation. It adapts to the topology of the image through the use of multiple masks. The algorithm is almost invariant under initialization, allowing for random initialization, and uses a few easily tunable parameters. Experiments show that the active mask algorithm matches the ground truth well and outperforms the algorithm widely used in fluorescence microscopy, seeded watershed, both qualitatively, as well as quantitatively.

  11. Carotid Intraplaque Hemorrhage Imaging with Quantitative Vessel Wall T1 Mapping: Technical Development and Initial Experience.

    Science.gov (United States)

    Qi, Haikun; Sun, Jie; Qiao, Huiyu; Chen, Shuo; Zhou, Zechen; Pan, Xinlei; Wang, Yishi; Zhao, Xihai; Li, Rui; Yuan, Chun; Chen, Huijun

    2018-04-01

    Purpose To develop a three-dimensional (3D) high-spatial-resolution time-efficient sequence for use in quantitative vessel wall T1 mapping. Materials and Methods A previously described sequence, simultaneous noncontrast angiography and intraplaque hemorrhage (SNAP) imaging, was extended by introducing 3D golden angle radial k-space sampling (GOAL-SNAP). Sliding window reconstruction was adopted to reconstruct images at different inversion delay times (different T1 contrasts) for voxelwise T1 fitting. Phantom studies were performed to test the accuracy of T1 mapping with GOAL-SNAP against a two-dimensional inversion recovery (IR) spin-echo (SE) sequence. In vivo studies were performed in six healthy volunteers (mean age, 27.8 years ± 3.0 [standard deviation]; age range, 24-32 years; five male) and five patients with atherosclerosis (mean age, 66.4 years ± 5.5; range, 60-73 years; five male) to compare T1 measurements between vessel wall sections (five per artery) with and without intraplaque hemorrhage (IPH). Statistical analyses included Pearson correlation coefficient, Bland-Altman analysis, and Wilcoxon rank-sum test with data permutation by subject. Results Phantom T1 measurements with GOAL-SNAP and IR SE sequences showed excellent correlation (R 2 = 0.99), with a mean bias of -25.8 msec ± 43.6 and a mean percentage error of 4.3% ± 2.5. Minimum T1 was significantly different between sections with IPH and those without it (mean, 371 msec ± 93 vs 944 msec ± 120; P = .01). Estimated T1 of normal vessel wall and muscle were 1195 msec ± 136 and 1117 msec ± 153, respectively. Conclusion High-spatial-resolution (0.8 mm isotropic) time-efficient (5 minutes) vessel wall T1 mapping is achieved by using the GOAL-SNAP sequence. This sequence may yield more quantitative reproducible biomarkers with which to characterize IPH and monitor its progression. © RSNA, 2017.

  12. Initial experience with the new da Vinci single-port robot-assisted platform.

    Science.gov (United States)

    Ballestero Diego, R; Zubillaga Guerrero, S; Truan Cacho, D; Carrion Ballardo, C; Velilla Diez, G; Calleja Hermosa, P; Gutiérrez Baños, J L

    2017-06-01

    To describe our experience in the first cases of urological surgeries performed with the da Vinci single-port robot-assisted platform. We performed 5 single-port robot-assisted surgeries (R-LESS) between May and October 2014. We performed 3 ureteral reimplant surgeries, one ureteropyeloplasty in an inverted kidney and 1 partial nephrectomy. The perioperative and postoperative results were collected, as well as a report of the complications according to the Clavien classification system. Of the 5 procedures, 4 were performed completely by LESS, while 1 procedure was reconverted to multiport robot-assisted surgery. There were no intraoperative complications. We observed perioperative complications in 4 patients, all of which were grade 1 or 2. The mean surgical time was 262minutes (range, 230-300). In our initial experience with the da Vinci device, R-LESS surgery was feasible and safe. There are still a number of limitations in its use, which require new and improved R-LESS platforms. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Magnetic resonance myocardial perfusion imaging-First experience at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Klumpp, B. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: bernhard.klumpp@med.uni-tuebingen.de; Hoevelborn, T. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Cardiology, Otfried-Mueller-Str. 10, 72076 Tuebingen (Germany)], E-mail: tobias.hoevelborn@gmx.de; Fenchel, M. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: michael.fenchel@med.uni-tuebingen.de; Stauder, N.I. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: norbert.stauder@stgag.ch; Kramer, U. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: ulrich.kramer@med.uni-tuebingen.de; May, A. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Cardiology, Otfried-Mueller-Str. 10, 72076 Tuebingen (Germany)], E-mail: andreas.may@med.uni-tuebingen.de; Gawaz, M.P. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Cardiology, Otfried-Mueller-Str. 10, 72076 Tuebingen (Germany)], E-mail: meinrad.gawaz@med.uni-tuebingen.de; Claussen, C.D. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: claus.claussen@med.uni-tuebingen.de; Miller, S. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: stephan.miller@med.uni-tuebingen.de

    2009-01-15

    Objective: MR myocardial perfusion imaging (MRMPI) is an established technique for the evaluation of the hemodynamical relevance of coronary artery disease. Perfusion imaging at 3.0 T provides certain advantages compared to 1.5 T. Aim of this study was to evaluate myocardial MR perfusion imaging at 3.0 T. Materials and methods: Twelve patients with stable Angina pectoris and known or suspected coronary artery disease were examined at 3.0 T. Myocardial perfusion was assessed using a saturation recovery gradient echo 2D sequence (TR 1.9 ms, TE 1.0 ms, FA 12 deg.) with 0.05 mmol Gd-DTPA per kg body weight at stress during injection of 140 {mu}g adenosine/kg body weight/min and at rest in short axis orientation. Perfusion analysis was based on a least square fit of the signal/time curve (peak signal intensity, slope). Perfusion series were assessed by two independent observers. Reference for the presence of relevant coronary artery stenoses was invasive coronary angiography. Two experienced observers evaluated the coronary angiograms in biplane projections for the presence and grade of stenoses. Results were compared with the MR perfusion analysis. Results: All MR examinations could be safely performed and yielded high image quality. In eight patients stress-induced hypoperfusion was detected (stenosis >70% in coronary angiography). In four patients myocardial hypoperfusion was ruled out (stenosis <70%). The myocardial perfusion reserve index was significantly reduced in hypoperfused myocardium with 1.9 {+-} 1.6 compared to 2.5 {+-} 1.6 in regularly perfused myocardium (p < 0.05). In coronary angiography, eight patients were found to suffer from coronary artery disease, whereas in four patients coronary artery disease was ruled out. Conclusion: Our initial results show that MRMPI at 3.0 T provides reliably high-image quality and diagnostic accuracy.

  14. [Aortic valve preservation in Marfan syndrome. Initial experience].

    Science.gov (United States)

    Forteza, Alberto; Cortina, Jose M; Sánchez, Violeta; Centeno, Jorge; López, M Jesús; Pérez de la Sota, Enrique; Rufilanchas, Juan J

    2007-05-01

    Preservation of the aortic valve using the technique described by David has been shown to be as effective as the Bentall-De Bono procedure. It avoids both the need for long-term anticoagulation and the complications associated with mechanical prostheses. We report our initial experience using this technique in patients with Marfan syndrome. Between April 2004 and April 2006, we used the David reimplantation technique in 40 patients with an aortic root aneurysm. Eighteen patients had Marfan syndrome. Their median age was 29 years (13-55 years). Echocardiography showed that the median diameter of the aortic sinus was 53 mm (46-59 mm). In 17 patients, aortic valve preservation was possible. No patient died during hospitalization and there were no significant complications. On echocardiography at discharge, no patient had greater than grade-II aortic regurgitation. During a median follow-up period of 8 months (1-24 months), one patient died due to rupture of an abdominal aneurysm. The others are all in New York Heart Association class I. Preservation of the aortic valve by means of valve reimplantation produced excellent results. It avoided both the thromboembolic and hemorrhagic complications associated with prostheses and the need for long-term anticoagulation. If reimplanted valves continue to function adequately over the long term, this technique should become the treatment of choice for aneurysms of the ascending aorta in patients with Marfan syndrome.

  15. Local experience on radionuclide myocardial imaging in the Philippines at the Philippine Heart Center for Asia

    International Nuclear Information System (INIS)

    Villacorta, E.V.

    1977-01-01

    The Nuclear Medicine Department of the Philippine Heart Center has introduced the detection of coronary heart disease through myocardiac perfusion imaging. The cardiovascular procedures are availed of free-of-charge to registered PHCA patients excepting for the costly TI-201 imaging. In summary, coronary perfusion in imaging should be an integral part of coronary arteriography. Barring the expensive cost of TI-120, myocardial perfusion imaging is ideal for detection of coronary heart disease. Experience shows better sensitivity of TI-201 than exercise ECG for detection of ischemia. Another non-invasive procedure for the detection of acute infarction is the radionuclide imaging using a bone radiopharmaceutical Tc99m prophosphate. In conclusion, acute infarct imaging is a valuable adjunct to ECG and enzyme studies. (RTD)

  16. Using Deduplicating Storage for Efficient Disk Image Deployment

    Directory of Open Access Journals (Sweden)

    Xing Lin

    2015-08-01

    Full Text Available Many clouds and network testbeds use disk images to initialize local storage on their compute devices. Large facilities must manage thousands or more images, requiring significant amounts of storage. At the same time, to provide a good user experience, they must be able to deploy those images quickly. Driven by our experience in operating the Emulab site at the University of Utah---a long-lived and heavily-used testbed---we have created a new service for efficiently storing and deploying disk images. This service exploits the redundant data found in similar images, using deduplication to greatly reduce the amount of physical storage required. In addition to space savings, our system is also designed for highly efficient image deployment---it integrates with an existing highly-optimized disk image deployment system, Frisbee, without significantly increasing the time required to distribute and install images. In this paper, we explain the design of our system and discuss the trade-offs we made to strike a balance between efficient storage and fast disk image deployment. We also propose a new chunking algorithm, called AFC, which enables fixed-size chunking for deduplicating allocated disk sectors. Experimental results show that our system reduces storage requirements by up to 3x while imposing only a negligible runtime overhead on the end-to-end disk-deployment process.

  17. Whole slide images and digital media in pathology education, testing, and practice: the Oklahoma experience.

    Science.gov (United States)

    Fung, Kar-Ming; Hassell, Lewis A; Talbert, Michael L; Wiechmann, Allan F; Chaser, Brad E; Ramey, Joel

    2012-01-01

    Examination of glass slides is of paramount importance in pathology training. Until the introduction of digitized whole slide images that could be accessed through computer networks, the sharing of pathology slides was a major logistic issue in pathology education and practice. With the help of whole slide images, our department has developed several online pathology education websites. Based on a modular architecture, this program provides online access to whole slide images, still images, case studies, quizzes and didactic text at different levels. Together with traditional lectures and hands-on experiences, it forms the back bone of our histology and pathology education system for residents and medical students. The use of digitized whole slide images has a.lso greatly improved the communication between clinicians and pathologist in our institute.

  18. Blind CT image quality assessment via deep learning strategy: initial study

    Science.gov (United States)

    Li, Sui; He, Ji; Wang, Yongbo; Liao, Yuting; Zeng, Dong; Bian, Zhaoying; Ma, Jianhua

    2018-03-01

    Computed Tomography (CT) is one of the most important medical imaging modality. CT images can be used to assist in the detection and diagnosis of lesions and to facilitate follow-up treatment. However, CT images are vulnerable to noise. Actually, there are two major source intrinsically causing the CT data noise, i.e., the X-ray photo statistics and the electronic noise background. Therefore, it is necessary to doing image quality assessment (IQA) in CT imaging before diagnosis and treatment. Most of existing CT images IQA methods are based on human observer study. However, these methods are impractical in clinical for their complex and time-consuming. In this paper, we presented a blind CT image quality assessment via deep learning strategy. A database of 1500 CT images is constructed, containing 300 high-quality images and 1200 corresponding noisy images. Specifically, the high-quality images were used to simulate the corresponding noisy images at four different doses. Then, the images are scored by the experienced radiologists by the following attributes: image noise, artifacts, edge and structure, overall image quality, and tumor size and boundary estimation with five-point scale. We trained a network for learning the non-liner map from CT images to subjective evaluation scores. Then, we load the pre-trained model to yield predicted score from the test image. To demonstrate the performance of the deep learning network in IQA, correlation coefficients: Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are utilized. And the experimental result demonstrate that the presented deep learning based IQA strategy can be used in the CT image quality assessment.

  19. Integrated global digital image correlation for interface delamination characterization

    KAUST Repository

    Hoefnagels, Johan P.M.

    2013-07-23

    Interfacial delamination is a key reliability challenge in composites and micro-electronic systems due to (high-density) integration of dissimilar materials. Predictive finite element models are used to minimize delamination failures during design, but require accurate interface models to capture (irreversible) crack initiation and propagation behavior observed in experiments. Therefore, an Integrated Global Digital Image Correlation (I-GDIC) strategy is developed for accurate determination of mechanical interface behavior from in-situ delamination experiments. Recently, a novel miniature delamination setup was presented that enables in-situ microscopic characterization of interface delamination while sensitively measuring global load-displacement curves for all mode mixities. Nevertheless, extraction of detailed mechanical interface behavior from measured images is challenging, because deformations are tiny and measurement noise large. Therefore, an advanced I-GDIC methodology is developed which correlates the image patterns by only deforming the images using kinematically-admissible \\'eigenmodes\\' that correspond to the few parameters controlling the interface tractions in an analytic description of the crack tip deformation field, thereby greatly enhancing accuracy and robustness. This method is validated on virtual delamination experiments, simulated using a recently developed self-adaptive cohesive zone (CZ) finite element framework. © The Society for Experimental Mechanics, Inc. 2014.

  20. Neutral Transport Simulations of Gas Puff Imaging Experiments on Alcator C-Mod

    International Nuclear Information System (INIS)

    Stotler, D.P.; LaBombard, B.; Terry, J.L.; Zweben, S.J.

    2002-01-01

    Visible imaging of gas puffs has been used on the Alcator C-Mod tokamak to characterize edge plasma turbulence, yielding data that can be compared with plasma turbulence codes. Simulations of these experiments with the DEGAS 2 Monte Carlo neutral transport code have been carried out to explore the relationship between the plasma fluctuations and the observed light emission. By imposing two-dimensional modulations on the measured time-average plasma density and temperature profiles, we demonstrate that the spatial structure of the emission cloud reflects that of the underlying turbulence. However, the photon emission rate depends on the plasma density and temperature in a complicated way, and no simple scheme for inferring the plasma parameters directly from the light emission patterns is apparent. The simulations indicate that excited atoms generated by molecular dissociation are a significant source of photons, further complicating interpretation of the gas puff imaging results.Visibl e imaging of gas puffs has been used on the Alcator C-Mod tokamak to characterize edge plasma turbulence, yielding data that can be compared with plasma turbulence codes. Simulations of these experiments with the DEGAS 2 Monte Carlo neutral transport code have been carried out to explore the relationship between the plasma fluctuations and the observed light emission. By imposing two-dimensional modulations on the measured time-average plasma density and temperature profiles, we demonstrate that the spatial structure of the emission cloud reflects that of the underlying turbulence. However, the photon emission rate depends on the plasma density and temperature in a complicated way, and no simple scheme for inferring the plasma parameters directly from the light emission patterns is apparent. The simulations indicate that excited atoms generated by molecular dissociation are a significant source of photons, further complicating interpretation of the gas puff imaging results

  1. MR imaging of prostate. Preliminary experience with calculated imaging in 28 cases

    International Nuclear Information System (INIS)

    Gevenois, P.A.; Van Regemorter, G.; Ghysels, M.; Delepaut, A.; Van Gansbeke, D.; Struyven, J.

    1988-01-01

    The majority of studies with MR imaging in prostate disease are based on a semiology obtained using images weighted in T1 and T2. A study was carried out to evaluate effects of images calculated in T1 and T2 obtained at 0.5T. This preliminary study concerns 28 prostate examinations with spin-echo acquisition and inversion-recuperation parameters, and provided images calculated in T1, weighted and calculated in T2. Images allowed detection and characterization of prostate lesions. However, although calculated images accentuate discrimination of the method, the weighted images conserve their place because of their improved spatial resolution [fr

  2. Initial clinical experience with a quadrupole butterfly coil for spinal injection interventions in an open MRI system at 1.0 tesla.

    Science.gov (United States)

    Jonczyk, Martin; Hamm, Bernd; Heinrich, Andreas; Thomas, Andreas; Rathke, Hendrik; Schnackenburg, Bernhard; Güttler, Felix; Teichgräber, Ulf K M; de Bucourt, Maximilian

    2014-02-01

    To report our initial clinical experience with a new magnetic resonance imaging (MRI) quadrupole coil that allows interventions in prone position. Fifteen patients (seven women, eight men; average age, 42.8 years) were treated in the same 1.0-Tesla Panorama High Field Open (HFO) MRI system (Panorama HFO) using a quadrupole butterfly coil (Bfly) and compared with 15 patients matched for sex, age, and MR intervention using the MultiPurposeL coil (MPL), performed in conventional lateral decubitus position (all, Philips Medical Systems, Best, The Netherlands). All interventions were performed with a near-real-time proton density turbo spin echo (PD TSE) sequence (time to repeat/time to echo/flip angle/acquisition time, 600 ms/10 ms/90°/3 s/image). Qualitative and quantitative image analyses were performed, including signal intensity, signal-to-noise and contrast-to-noise ratio (SNR, CNR), contrast, and full width at half maximum (FWHM) measurements. Contrast differed significantly between the needle and muscles (Bfly 0.27/MPL 0.17), as well as the needle and periradicular fat (0.13/0.24) during the intervention (both, p=0.029), as well as the CNR between muscles and the needle (10.61/5.23; p=0.010), although the FWHM values did not (2.4/2.2; p=0.754). The signal intensity of the needle in interventional imaging (1152.9/793.2; p=0.006) and the postinterventional SNR values of subcutaneous fat (15.3/28.6; p=0.007), muscles (6.6/11.8; p=0.011), and the CNR between these tissues (8.7/17.5; p=0.004) yielded significant differences. The new coil is a valid alternative for MR-guided interventions in an open MRI system at 1.0 tesla, especially if patients cannot (or prefer not to) be in a lateral decubitus position or if prone positioning yields better access to the target zone.

  3. Preliminary Results of Nuclear Fluorescence Imaging of Alpha and Beta Emitting Sources

    International Nuclear Information System (INIS)

    Feener, Jessica S.; Charlton, William S.

    2013-06-01

    The preliminary results from a series of nuclear fluorescence imaging experiments using a variety of radioactive sources and shielding are given. These experiments were done as part of a proof of concept to determine if nuclear fluorescence imaging could be used as a safeguards measurements tool or for nuclear warhead verification for nuclear arms control treaties such as the New Strategic Arms Reduction Treaty and the Fissile Material Cut-Off Treaty. An off-the-shelf Princeton Instruments charged coupled device camera system was used to image the emission of fluorescence photons from the de-excitation of nitrogen molecules in air that have been excited by ionizing radiation. The fluorescence emissions are primarily in the near ultraviolet range; between the wavelengths of 300 and 400 nm. Fluorescent imaging techniques are currently being investigated in a number of applications. A French research team has successfully demonstrated this concept for remote imaging of alpha contamination. It has also been shown that the phenomenon can be seen through translucent materials and that alpha radiation can be seen in the presence of large gamma backgrounds. Additionally, fluorescence telescopes and satellites utilize the de-excitation of nitrogen molecules to observe cosmic ray showers in the atmosphere. In cosmic ray shower detection, electrons are the main contributor to the excitation of the of nitrogen molecules in air. The experiments presented in this paper were designed to determine if the imaging system could observe beta emitting sources, differentiate between beta emitters and alpha emitting materials such as uranium oxide and uranium metal, and to further investigate the phenomenon through translucent and non-translucent materials. The initial results show that differentiation can be made between beta and alpha emitting sources and that the device can observe the phenomenon through very thin non-transparent material. Additionally, information is given on the

  4. Associations between Forced Sexual Initiation, HIV Status, Sexual Risk Behavior, Life Stressors, and Coping Strategies among Adolescents in Nigeria

    Science.gov (United States)

    Folayan, Morenike Oluwatoyin

    2016-01-01

    Objectives Some individuals experience their first sexual intercourse through physically forced sex, which affects the way they experience and cope with stress. We examined differences in sexual risk behavior, experience of stressors, and use of stress-coping strategies among adolescents in Nigeria based on their history of forced sexual initiation and HIV status. Methods We analyzed data from 436 sexually active 10–19-year-old adolescents recruited through a population-based survey from 12 Nigerian states. Using Lazarus and Folkman’s conceptual framework of stress and coping, we assessed if adolescents who reported forced sexual initiation were more likely to report HIV sexual risk practices, to report as stressors events related to social expectations, medical care and body images, and loss and grief, and to use more avoidance than adaptive coping strategies to manage stress. We also assessed if HIV status affected experience of stressors and use of coping strategies. Results Eighty-one adolescents (18.6%) reported a history of forced sexual initiation; these participants were significantly more likely to report anal sex practices (OR: 5.04; 95% CI: 2.14–11.87), and transactional sex (OR: 2.80; 95% CI: 1.56–4.95). Adolescents with no history of forced sexual initiation were more likely to identify as stressors, life events related to social expectations (OR: 1.03; 95% CI: 0.96–1.11) and loss and grief (OR: 1.34; 95% CI: 0.73–2.65), but not those related to medical care and body images (OR: 0.63; 95% CI: 0.34–1.18). They were also more likely to use adaptive responses (OR: 1.48; 95% CI: 0.62–3.50) than avoidance responses (OR: 0.90; 95% CI: 0.49–1.64) to cope with stress, though these differences were not significant. More adolescents with a history of forced sexual initiation who were HIV positive identified as stressors, life events related to medical care and body images (p = 0.03) and loss and grief (p = 0.009). Adolescents reporting forced

  5. X-ray strain tensor imaging: FEM simulation and experiments with a micro-CT.

    Science.gov (United States)

    Kim, Jae G; Park, So E; Lee, Soo Y

    2014-01-01

    In tissue elasticity imaging, measuring the strain tensor components is necessary to solve the inverse problem. However, it is impractical to measure all the tensor components in ultrasound or MRI elastography because of their anisotropic spatial resolution. The objective of this study is to compute 3D strain tensor maps from the 3D CT images of a tissue-mimicking phantom. We took 3D micro-CT images of the phantom twice with applying two different mechanical compressions to it. Applying the 3D image correlation technique to the CT images under different compression, we computed 3D displacement vectors and strain tensors at every pixel. To evaluate the accuracy of the strain tensor maps, we made a 3D FEM model of the phantom, and we computed strain tensor maps through FEM simulation. Experimentally obtained strain tensor maps showed similar patterns to the FEM-simulated ones in visual inspection. The correlation between the strain tensor maps obtained from the experiment and the FEM simulation ranges from 0.03 to 0.93. Even though the strain tensor maps suffer from high level noise, we expect the x-ray strain tensor imaging may find some biomedical applications such as malignant tissue characterization and stress analysis inside the tissues.

  6. Supervised Self-Organizing Classification of Superresolution ISAR Images: An Anechoic Chamber Experiment

    Directory of Open Access Journals (Sweden)

    Radoi Emanuel

    2006-01-01

    Full Text Available The problem of the automatic classification of superresolution ISAR images is addressed in the paper. We describe an anechoic chamber experiment involving ten-scale-reduced aircraft models. The radar images of these targets are reconstructed using MUSIC-2D (multiple signal classification method coupled with two additional processing steps: phase unwrapping and symmetry enhancement. A feature vector is then proposed including Fourier descriptors and moment invariants, which are calculated from the target shape and the scattering center distribution extracted from each reconstructed image. The classification is finally performed by a new self-organizing neural network called SART (supervised ART, which is compared to two standard classifiers, MLP (multilayer perceptron and fuzzy KNN ( nearest neighbors. While the classification accuracy is similar, SART is shown to outperform the two other classifiers in terms of training speed and classification speed, especially for large databases. It is also easier to use since it does not require any input parameter related to its structure.

  7. Initial Investigation of preclinical integrated SPECT and MR imaging.

    Science.gov (United States)

    Hamamura, Mark J; Ha, Seunghoon; Roeck, Werner W; Wagenaar, Douglas J; Meier, Dirk; Patt, Bradley E; Nalcioglu, Orhan

    2010-02-01

    Single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high-spatial resolution anatomical information as well as complementary functional information. In this study, we utilized a dual modality SPECT/MRI (MRSPECT) system to investigate the integration of SPECT and MRI for improved image accuracy. The MRSPECT system consisted of a cadmium-zinc-telluride (CZT) nuclear radiation detector interfaced with a specialized radiofrequency (RF) coil that was placed within a whole-body 4 T MRI system. The importance of proper corrections for non-uniform detector sensitivity and Lorentz force effects was demonstrated. MRI data were utilized for attenuation correction (AC) of the nuclear projection data and optimized Wiener filtering of the SPECT reconstruction for improved image accuracy. Finally, simultaneous dual-imaging of a nude mouse was performed to demonstrated the utility of co-registration for accurate localization of a radioactive source.

  8. Initial tests of a prototype MRI-compatible PET imager

    International Nuclear Information System (INIS)

    Raylman, Raymond R.; Majewski, Stan; Lemieux, Susan; Velan, S. Sendhil; Kross, Brain; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.; Wojcik, Randy

    2006-01-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5x5x4 cm 3 . Each MRI-PET detector module consists of an array of LSO detector elements (2.5x2.5x15 mm 3 ) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of ∼60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to ∼85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy

  9. Simultaneous neutron and x-ray imaging of inertial confinement fusion experiments along a single line of sight at Omega

    Energy Technology Data Exchange (ETDEWEB)

    Danly, C. R.; Day, T. H.; Herrmann, H.; Kim, Y. H.; Martinez, J. I.; Merrill, F. E.; Schmidt, D. W.; Simpson, R. A.; Volegov, P. L.; Wilde, C. H. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States); Fittinghoff, D. N.; Izumi, N. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2015-04-15

    Neutron and x-ray imaging provide critical information about the geometry and hydrodynamics of inertial confinement fusion implosions. However, existing diagnostics at Omega and the National Ignition Facility (NIF) cannot produce images in both neutrons and x-rays along the same line of sight. This leads to difficulty comparing these images, which capture different parts of the plasma geometry, for the asymmetric implosions seen in present experiments. Further, even when opposing port neutron and x-ray images are available, they use different detectors and cannot provide positive information about the relative positions of the neutron and x-ray sources. A technique has been demonstrated on implosions at Omega that can capture x-ray images along the same line of sight as the neutron images. The technique is described, and data from a set of experiments are presented, along with a discussion of techniques for coregistration of the various images. It is concluded that the technique is viable and could provide valuable information if implemented on NIF in the near future.

  10. Simultaneous assessment of cerebral blood volume and diffusion heterogeneity using hybrid IVIM and DK MR imaging: initial experience with brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Wen-Chau [National Taiwan University, Graduate Institute of Oncology, Taipei (China); National Taiwan University, Graduate Institute of Clinical Medicine, Taipei (China); National Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics, Taipei (China); National Taiwan University Hospital, Department of Medical Imaging, Taipei (China); Yang, Shun-Chung; Chen, Ya-Fang; My, Pei-Chi [National Taiwan University Hospital, Department of Medical Imaging, Taipei (China); Tseng, Han-Min [National Taiwan University Hospital, Department of Neurology, Taipei (China)

    2017-01-15

    To investigate the feasibility of simultaneously assessing cerebral blood volume and diffusion heterogeneity using hybrid diffusion-kurtosis (DK) and intravoxel-incoherent-motion (IVIM) MR imaging. Fifteen healthy volunteers and 30 patients with histologically proven brain tumours (25 WHO grade II-IV gliomas and five metastases) were recruited. On a 3-T system, diffusion-weighted imaging was performed with six b-values ranging from 0 to 1,700 s/mm{sup 2}. Nonlinear least-squares fitting was employed to extract diffusion coefficient (D), diffusion kurtosis coefficient (K, a measure of the degree of non-Gaussian and heterogeneous diffusion) and intravascular volume fraction (f, a measure proportional to cerebral blood volume). Repeated-measures multivariate analysis of variance and receiver operating characteristic analysis were performed to assess the ability of D/K/f in differentiating contrast-enhanced tumour from peritumoral oedema and normal-appearing white matter. Based on our imaging setting (baseline signal-to-noise ratio = 32-128), coefficient of variation was 14-20 % for K, ∝6 % for D and 26-44 % for f. The indexes were able to differentiate contrast-enhanced tumour (Wilks' λ = 0.026, p < 10{sup -3}), and performance was greatest with K, followed by f and D. Hybrid DK IVIM imaging is capable of simultaneously measuring cerebral perfusion and diffusion indexes that together may improve brain tumour diagnosis. (orig.)

  11. Does obtaining an initial magnetic resonance imaging decrease the reamputation rates in the diabetic foot?

    Directory of Open Access Journals (Sweden)

    Marlena Jbara

    2016-06-01

    Full Text Available Objective: Diabetes mellitus (DM through its over glycosylation of neurovascular structures and resultant peripheral neuropathy continues to be the major risk factor for pedal amputation. Repetitive trauma to the insensate foot results in diabetic foot ulcers, which are at high risk to develop osteomyelitis. Many patients who present with diabetic foot complications will undergo one or more pedal amputations during the course of their disease. The purpose of this study was to determine if obtaining an initial magnetic resonance imaging (MRI, prior to the first amputation, is associated with a decreased rate of reamputation in the diabetic foot. Our hypothesis was that the rate of reamputation may be associated with underutilization of obtaining an initial MRI, useful in presurgical planning. This study was designed to determine whether there was an association between the reamputation rate in diabetic patients and utilization of MRI in the presurgical planning and prior to initial forefoot amputations. Methods: Following approval by our institutional review board, our study design consisted of a retrospective cohort analysis of 413 patients at Staten Island University Hospital, a 700-bed tertiary referral center between 2008 and 2013 who underwent an initial great toe (hallux amputation. Of the 413 patients with a hallux amputation, there were 368 eligible patients who had a history of DM with documented hemoglobin A1c (HbA1c within 3 months of the initial first ray (hallux and first metatarsal amputation and available radiographic data. Statistical analysis compared the incidence rates of reamputation between patients who underwent initial MRI and those who did not obtain an initial MRI prior to their first amputation. The reamputation rate was compared after adjustment for age, gender, ethnicity, HbA1c, cardiovascular disease, hypoalbuminemia, smoking, body mass index, and prior antibiotic treatment. Results: The results of our statistical

  12. Pediatric hypertension: An approach to imaging

    International Nuclear Information System (INIS)

    Diament, M.J.; Stanley, P.; Gilsanz, V.; Boechat, M.I.; Kangarloo, H.; Lieberman, E.R.

    1986-01-01

    Since 1981, we have made diagnoses of secondary hypertension using state of art imaging equipment in 18 pediatric patients. The most valuable tests were ultrasound identifying renal parenchymal disease, computed body tomography for adrenal tumors and intra-arterial renal angiography for renovascular disorders. Based on our experience, we have formulated an algorithm for the evaluation of the hypertensive pediatric patient. The initial step is careful clinical and laboratory screening to identify those patients that are likely to have essential hypertension and who should not undergo imaging tests. In the cases where there is a possible secondary etiology, renal ultrasound is usually performed first to identify parenchymal disease. If catecholamines are elevated, then abdominal computed tomography is the initial test. If no etiology is identified from these noninvasive studies, then direct intraarterial renal angiography is performed. The authors do not feel that excretory urography, radionuclide renography, intravenous digital subtraction angiography or selective renal vein sampling for renin are useful or practical screening tests for renovascular hypertension. (orig.)

  13. Pediatric hypertension: An approach to imaging

    Energy Technology Data Exchange (ETDEWEB)

    Diament, M J; Stanley, P; Gilsanz, V; Boechat, M I; Kangarloo, H; Lieberman, E R

    1986-09-01

    Since 1981, we have made diagnoses of secondary hypertension using state of art imaging equipment in 18 pediatric patients. The most valuable tests were ultrasound identifying renal parenchymal disease, computed body tomography for adrenal tumors and intra-arterial renal angiography for renovascular disorders. Based on our experience, we have formulated an algorithm for the evaluation of the hypertensive pediatric patient. The initial step is careful clinical and laboratory screening to identify those patients that are likely to have essential hypertension and who should not undergo imaging tests. In the cases where there is a possible secondary etiology, renal ultrasound is usually performed first to identify parenchymal disease. If catecholamines are elevated, then abdominal computed tomography is the initial test. If no etiology is identified from these noninvasive studies, then direct intraarterial renal angiography is performed. The authors do not feel that excretory urography, radionuclide renography, intravenous digital subtraction angiography or selective renal vein sampling for renin are useful or practical screening tests for renovascular hypertension.

  14. ViCAR: An Adaptive and Landmark-Free Registration of Time Lapse Image Data from Microfluidics Experiments

    Directory of Open Access Journals (Sweden)

    Georges Hattab

    2017-05-01

    Full Text Available In order to understand gene function in bacterial life cycles, time lapse bioimaging is applied in combination with different marker protocols in so called microfluidics chambers (i.e., a multi-well plate. In one experiment, a series of T images is recorded for one visual field, with a pixel resolution of 60 nm/px. Any (semi-automatic analysis of the data is hampered by a strong image noise, low contrast and, last but not least, considerable irregular shifts during the acquisition. Image registration corrects such shifts enabling next steps of the analysis (e.g., feature extraction or tracking. Image alignment faces two obstacles in this microscopic context: (a highly dynamic structural changes in the sample (i.e., colony growth and (b an individual data set-specific sample environment which makes the application of landmarks-based alignments almost impossible. We present a computational image registration solution, we refer to as ViCAR: (Visual (Cues based (Adaptive (Registration, for such microfluidics experiments, consisting of (1 the detection of particular polygons (outlined and segmented ones, referred to as visual cues, (2 the adaptive retrieval of three coordinates throughout different sets of frames, and finally (3 an image registration based on the relation of these points correcting both rotation and translation. We tested ViCAR with different data sets and have found that it provides an effective spatial alignment thereby paving the way to extract temporal features pertinent to each resulting bacterial colony. By using ViCAR, we achieved an image registration with 99.9% of image closeness, based on the average rmsd of 4.10−2 pixels, and superior results compared to a state of the art algorithm.

  15. Experience on country brand website and the formation of tourist des-tination image: a study in Iceland

    Directory of Open Access Journals (Sweden)

    Dirceu Tornavoi de Carvalho

    2016-03-01

    Full Text Available The research aims to verify if the experience with country brands website influences the image and attractiveness of a touristic destination in the consumers’ minds as also in their intention to visit the destination. A pre-test/post-test pre-experimental study with a 30 undergraduate students sample in a university of São Paulo was conducted. The treatment consisted of exposing the subjects to the Iceland official touristic site. The dependent variables were the touristic attractiveness perception and the intention to visit Iceland. The evaluation of the browsing experience was measured using scales of online consumer behavior literature. The two hypotheses were: (1 that positive online experience positively influences the destination image formation and (2 positively influences the intention of visit, were supported by statistical means comparison tests before and after treatment. The content analysis of the open question, performed after treatment, showed the effect that the knowledge acquired by pleasurable navigation have in shaping the image and increasing the intention of visiting a touristic destination.

  16. Initiation of Addiction Treatment and Access to Services: Young Adults' Accounts of Their Help-Seeking Experiences.

    Science.gov (United States)

    Wagner, Vincent; Bertrand, Karine; Flores-Aranda, Jorge; Acier, Didier; Brunelle, Natacha; Landry, Michel; Brochu, Serge

    2017-09-01

    Substance addiction in young adults is particularly problematic. Yet, much remain at stake in understanding the specifics of this population's access to services. The objective of this study is to explore young adults' initiation of substance misuse treatment. Our study sample was composed of 35 individuals aged 18 to 30 with problematic psychoactive substance use who have been identified in criminal courts, hospital emergency departments, and Health and Social Services Centers in Québec (Canada). A thematic analysis was performed on the 62 semi-structured interviews conducted with participants. Three components emerged. First, personal elements-expectations, individual motivations, perceptions of use, and capacity to control it-influence initiation of substance misuse treatment. Second, family and peers have noticeable influences. Finally, system characteristics and prior care experiences also shape the process. Consideration should be given to tailor interventions that can reach young adults and encourage them to initiate appropriate care.

  17. 3D registration of surfaces for change detection in medical images

    Science.gov (United States)

    Fisher, Elizabeth; van der Stelt, Paul F.; Dunn, Stanley M.

    1997-04-01

    Spatial registration of data sets is essential for quantifying changes that take place over time in cases where the position of a patient with respect to the sensor has been altered. Changes within the region of interest can be problematic for automatic methods of registration. This research addresses the problem of automatic 3D registration of surfaces derived from serial, single-modality images for the purpose of quantifying changes over time. The registration algorithm utilizes motion-invariant, curvature- based geometric properties to derive an approximation to an initial rigid transformation to align two image sets. Following the initial registration, changed portions of the surface are detected and excluded before refining the transformation parameters. The performance of the algorithm was tested using simulation experiments. To quantitatively assess the registration, random noise at various levels, known rigid motion transformations, and analytically-defined volume changes were applied to the initial surface data acquired from models of teeth. These simulation experiments demonstrated that the calculated transformation parameters were accurate to within 1.2 percent of the total applied rotation and 2.9 percent of the total applied translation, even at the highest applied noise levels and simulated wear values.

  18. CT Imaging for Evaluation of Calcium Crystal Deposition in the Knee: Initial Experience from The Multicenter Osteoarthritis (MOST) Study

    Science.gov (United States)

    Misra, Devyani; Guermazi, Ali; Sieren, Jered P.; Lynch, John; Torner, James; Neogi, Tuhina; Felson, David T.

    2014-01-01

    Objective Role of intra-articular calcium crystals in osteoarthritis (OA) is unclear. Imaging modalities used to date for its evaluation have limitations in their ability to fully characterize intra-articular crystal deposition. Since Computed Tomography (CT) imaging provides excellent visualization of bones and calcified tissue, in this pilot project we evaluated the utility of CT scan in describing intra-articular calcium crystal deposition in the knees. Method We included 12 subjects with and 4 subjects without radiographic chondrocalcinosis in the most recent visit from the Multicenter Osteoarthritis (MOST) study, which is a longitudinal cohort of community-dwelling older adults with or at risk for knee OA. All subjects underwent CT scans of bilateral knees. Each knee was divided into 25 subregions and each subregion was read for presence of calcium crystals by a musculoskeletal radiologist. To assess reliability, readings were repeated 4 weeks later. Results CT images permitted visualization of 25 subregions with calcification within and around the tibio-femoral and patello-femoral joints in all 24 knees with radiographic chondrocalcinosis. Intra-articular calcification was seen universally including meniscal cartilage (most common site involved in 21/24 knees), hyaline cartilage, cruciate ligaments, medial collateral ligament and joint capsule. Readings showed good agreement for specific tissues involved with calcium deposition (kappa: 0.70, 95% CI 0.62–0.80). Conclusion We found CT scan to be a useful and reliable tool for describing calcium crystal deposition in the knee and therefore potentially for studying role of calcium crystals in OA. We also confirmed that “chondrocalcinosis” is a misnomer because calcification is present ubiquitously. PMID:25451303

  19. Initial tests of a prototype MRI-compatible PET imager

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R. [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States)]. E-mail: rraylman@wvu.edu; Majewski, Stan [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Lemieux, Susan [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States); Velan, S. Sendhil [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States); Kross, Brain [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Popov, Vladimir [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Smith, Mark F. [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Weisenberger, Andrew G. [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Wojcik, Randy [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2006-12-20

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5x5x4 cm{sup 3}. Each MRI-PET detector module consists of an array of LSO detector elements (2.5x2.5x15 mm{sup 3}) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of {approx}60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to {approx}85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy.

  20. Imaging CT findings in cases of subdural hematoma after cardiovascular surgery. Initial signs of SDH

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Michiyuki; Kuriyama, Yoshihiro; Sawada, Tohru; Ogawa, Makoto; Kaneko, Takaji; Sakamoto, Akira; Kawazoe, Kouhei; Fujita, Tsuyoshi; Omae, Teruo

    1987-12-01

    A characteristic initial sign of CT findings, as seen in cases of subdural hematoma (SDH) after cardiovascular surgery, was reported. Central-nervous-system (CNS) complications after cardiovascular surgery have been thought to be due mainly to the ischemic brain damage caused by both reduced cerebral perfusion pressure and microembolism during extracorporeal circulation. However, we observed 8 cases of SDH in 39 patients suffering from major CNS complications after cardiovascular surgery. In view of these experiences, SDH was thought to be one of the most significant factors causing CNS complications after cardiovascular surgery. In the sequential CT scans of 8 cases of SDH, four exhibited a typical, small, spotty high-density area in the early period of SDH. The clinical courses of these four patients were relatively acute or subacute, and the initial small high-density area progressed to definite SDH findings in that region in the follow-up CT. These initial findings of CT scans were regarded as ''initial signs of SDH-ISS-''. Although there have been many reports concerning the sequential CT changes in SDH, there has been no report describing the above-mentioned finding. It was emphasized that ''ISS'' is of great importance in the early management for SDH.

  1. THAI-SPICE: Testbed for High-Acuity Imaging – Stable Photometry and ImageMotion Compensation Experiment

    Science.gov (United States)

    Young, Eliot

    THAI-SPICE is the Testbed for High-Acuity Imaging - Stable Photometry and ImageMotion Compensation Experiment - It is a lead proposal, accompanied by a coInstitutional proposal from MIT LL. The overarching goal of THAI-SPICE is to advance balloonborne telescopes to the point where they can surpass HST in terms of spatial resolution in visible wavelengths and surpass the Kepler mission in terms of observing exoplanet transits. Balloon-borne telescopes are becoming an important part of NASA's observing programs - each 100-day super-pressure balloon flight will provide 1000 hours of dark time observing, equivalent to about 1/3 of the total on-target time allocated in an HST cycle across its entire portfolio of science programs. However, balloon-borne telescopes face unique challenges from the stratospheric thermal environment and the pointing stability of a suspended platform. This proposal will study and test three areas of development that will enable high-acuity image quality and stable photometry from balloon-borne telescopes. - Passive thermal control and stabilization of balloon-borne OTAs (Optical Tube Assemblies). Recent modeling suggests that an appropriate arrangement of sunshields, earth-shields and telescope insulation can reduce diurnal temperature excursions from more than 40°C to less than 2°C. Furthermore, modeling also suggests that the steadystate temperature of an OTA can be reduced to temperatures near 180 K, an advantage for infrared observing programs. However, most modeling packages (e.g., Thermal Desktop) do not accurately account for convection in the 3 torr or 8 torr environment of zeropressure or super-pressure balloons. In fact, it is hard to tell whether radiation or convection is a more significant cooling mechanism at super-pressure balloon altitudes. We propose to verify or update Thermal Desktop results with a series of experiments using an instrumented OTA and sun- and earth-shields. The payoff from this experiment will be balloon

  2. Magnetic resonance image segmentation using semi-automated software for quantification of knee articular cartilage - initial evaluation of a technique for paired scans

    International Nuclear Information System (INIS)

    Brem, M.H.; Lang, P.K.; Neumann, G.; Schlechtweg, P.M.; Yoshioka, H.; Pappas, G.; Duryea, J.; Schneider, E.; Jackson, R.; Yu, J.; Eaton, C.B.; Hennig, F.F.

    2009-01-01

    Software-based image analysis is important for studies of cartilage changes in knee osteoarthritis (OA). This study describes an evaluation of a semi-automated cartilage segmentation software tool capable of quantifying paired images for potential use in longitudinal studies of knee OA. We describe the methodology behind the analysis and demonstrate its use by determination of test-retest analysis precision of duplicate knee magnetic resonance imaging (MRI) data sets. Test-retest knee MR images of 12 subjects with a range of knee health were evaluated from the Osteoarthritis Initiative (OAI) pilot MR study. Each subject was removed from the magnet between the two scans. The 3D DESS (sagittal, 0.456 mm x 0.365 mm, 0.7 mm slice thickness, TR 16.5 ms, TE 4.7 ms) images were obtained on a 3-T Siemens Trio MR system with a USA Instruments quadrature transmit-receive extremity coil. Segmentation of one 3D-image series was first performed and then the corresponding retest series was segmented by viewing both image series concurrently in two adjacent windows. After manual registration of the series, the first segmentation cartilage outline served as an initial estimate for the second segmentation. We evaluated morphometric measures of the bone and cartilage surface area (tAB and AC), cartilage volume (VC), and mean thickness (ThC.me) for medial/lateral tibia (MT/LT), total femur (F) and patella (P). Test-retest reproducibility was assessed using the root-mean square coefficient of variation (RMS CV%). For the paired analyses, RMS CV % ranged from 0.9% to 1.2% for VC, from 0.3% to 0.7% for AC, from 0.6% to 2.7% for tAB and 0.8% to 1.5% for ThC.me. Paired image analysis improved the measurement precision of cartilage segmentation. Our results are in agreement with other publications supporting the use of paired analysis for longitudinal studies of knee OA. (orig.)

  3. Magnetic resonance image segmentation using semi-automated software for quantification of knee articular cartilage - initial evaluation of a technique for paired scans

    Energy Technology Data Exchange (ETDEWEB)

    Brem, M.H. [Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); Friedrich-Alexander-University Erlangen Nurenberg, Division of Orthopaedic and Trauma Surgery, Department of Surgery, Erlangen (Germany); Lang, P.K.; Neumann, G.; Schlechtweg, P.M.; Yoshioka, H.; Pappas, G.; Duryea, J. [Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); Schneider, E. [LLC, SciTrials, Rocky River, OH (United States); Cleveland Clinic, Imaging Institute, Cleveland, OH (United States); Jackson, R.; Yu, J. [Ohio State University, Diabetes and Metabolism and Radiology, Department of Endocrinology, Columbus, OH (United States); Eaton, C.B. [Center for Primary Care and Prevention and the Warren Alpert Medical School of Brown University, Memorial Hospital of Rhode Island, Providence, RI (United States); Hennig, F.F. [Friedrich-Alexander-University Erlangen Nurenberg, Division of Orthopaedic and Trauma Surgery, Department of Surgery, Erlangen (Germany)

    2009-05-15

    Software-based image analysis is important for studies of cartilage changes in knee osteoarthritis (OA). This study describes an evaluation of a semi-automated cartilage segmentation software tool capable of quantifying paired images for potential use in longitudinal studies of knee OA. We describe the methodology behind the analysis and demonstrate its use by determination of test-retest analysis precision of duplicate knee magnetic resonance imaging (MRI) data sets. Test-retest knee MR images of 12 subjects with a range of knee health were evaluated from the Osteoarthritis Initiative (OAI) pilot MR study. Each subject was removed from the magnet between the two scans. The 3D DESS (sagittal, 0.456 mm x 0.365 mm, 0.7 mm slice thickness, TR 16.5 ms, TE 4.7 ms) images were obtained on a 3-T Siemens Trio MR system with a USA Instruments quadrature transmit-receive extremity coil. Segmentation of one 3D-image series was first performed and then the corresponding retest series was segmented by viewing both image series concurrently in two adjacent windows. After manual registration of the series, the first segmentation cartilage outline served as an initial estimate for the second segmentation. We evaluated morphometric measures of the bone and cartilage surface area (tAB and AC), cartilage volume (VC), and mean thickness (ThC.me) for medial/lateral tibia (MT/LT), total femur (F) and patella (P). Test-retest reproducibility was assessed using the root-mean square coefficient of variation (RMS CV%). For the paired analyses, RMS CV % ranged from 0.9% to 1.2% for VC, from 0.3% to 0.7% for AC, from 0.6% to 2.7% for tAB and 0.8% to 1.5% for ThC.me. Paired image analysis improved the measurement precision of cartilage segmentation. Our results are in agreement with other publications supporting the use of paired analysis for longitudinal studies of knee OA. (orig.)

  4. Initiation of simian virus 40 DNA replication in vitro: Pulse-chase experiments identify the first labeled species as topologically unwound

    International Nuclear Information System (INIS)

    Bullock, P.A.; Seo, Yeon Soo; Hurwitz, J.

    1989-01-01

    A distinct unwound form of DNA containing the simian virus 40 (SV40) origin is produced in replication reactions carried out in mixtures containing crude fractions prepared from HeLa cells. This species, termed form U R , comigrates on chloroquine-containing agarose gels with the upper part of the previously described heterogeneous highly unwound circular DNA, form U. As with form U, formation of form U R is dependent upon the SV40 tumor (T) antigen. Pulse-chase experiments demonstrate that the first species to incorporate labeled deoxyribonucleotides comigrates with form U R . Restriction analyses of the products of the pulse-chase experiments show that initiation occurs at the SV40 origin and then proceeds outward in a bidirectional manner. These experiments establish form U R as the earliest detectable substrate for SV40 DNA replication and suggest that SV40 DNA replication initiates on an unwound species

  5. Validation results of satellite mock-up capturing experiment using nets

    Science.gov (United States)

    Medina, Alberto; Cercós, Lorenzo; Stefanescu, Raluca M.; Benvenuto, Riccardo; Pesce, Vincenzo; Marcon, Marco; Lavagna, Michèle; González, Iván; Rodríguez López, Nuria; Wormnes, Kjetil

    2017-05-01

    The PATENDER activity (Net parametric characterization and parabolic flight), funded by the European Space Agency (ESA) via its Clean Space initiative, was aiming to validate a simulation tool for designing nets for capturing space debris. This validation has been performed through a set of different experiments under microgravity conditions where a net was launched capturing and wrapping a satellite mock-up. This paper presents the architecture of the thrown-net dynamics simulator together with the set-up of the deployment experiment and its trajectory reconstruction results on a parabolic flight (Novespace A-310, June 2015). The simulator has been implemented within the Blender framework in order to provide a highly configurable tool, able to reproduce different scenarios for Active Debris Removal missions. The experiment has been performed over thirty parabolas offering around 22 s of zero-g conditions. Flexible meshed fabric structure (the net) ejected from a container and propelled by corner masses (the bullets) arranged around its circumference have been launched at different initial velocities and launching angles using a pneumatic-based dedicated mechanism (representing the chaser satellite) against a target mock-up (the target satellite). High-speed motion cameras were recording the experiment allowing 3D reconstruction of the net motion. The net knots have been coloured to allow the images post-process using colour segmentation, stereo matching and iterative closest point (ICP) for knots tracking. The final objective of the activity was the validation of the net deployment and wrapping simulator using images recorded during the parabolic flight. The high-resolution images acquired have been post-processed to determine accurately the initial conditions and generate the reference data (position and velocity of all knots of the net along its deployment and wrapping of the target mock-up) for the simulator validation. The simulator has been properly

  6. [Management of recurrent urethrocutaneous fistula after hypospadias surgery in pediatric patients: initial experience with dermal regeneration sheet Integra].

    Science.gov (United States)

    Casal-Beloy, I; Somoza Argibay, I; García-González, M; García-Novoa, A M; Míguez Fortes, L; Blanco, C; Dargallo Carbonell, T

    2017-10-25

    To present our initial experience using a dermal regeneration sheet as an urethral cover in the repair of recurrent urethrocutaneous fistulae in pediatric patients. Since May 2016 to March a total of 8 fistulaes were repaired using this new technique. We performed the ddissection of the fistulous tract and posterior closure of the urethral defect. A dermal regeneration sheet was used to cover the urethral suture. Finally a rotational flap was performed to avoid overlap sutures. During the follow-up (average 6 months), one patient presented in the immediate postoperative period infection of the surgical wound. This patient presented recurrence of the fistula. 88% of the patients included presented a good evolution with no other complications. In our initial experience the new technique seems easy, safe and effective in the management of the recurrent urethrocutaneous fistulae in pediatric patients. More studies are needed to prove these results.

  7. Crossing the gender boundaries: The gender experiences of male nursing students in initial nursing clinical practice in Taiwan.

    Science.gov (United States)

    Liu, Hsing-Yuan; Li, Yun Ling

    2017-11-01

    The initial nursing clinical practice is the necessary practicum required for nursing students. Because of the changing learning style, many of them are under great pressure for environmental change and therefore their daily routine is severe affected. Interacting directly with patients in a female-dominated occupation, along with the general gender stereotypes, the impact is especially significant to male nursing students than to female nursing students. The purpose of this preliminary qualitative study is to explore the gendered experiences of male nursing students during their first initial nursing clinical practice. Both focus group interviews and individual interviews are conducted with twenty-two sophomore nursing students from a university of technology in northern Taiwan, with ten male students and twelve female students. Two main themes emerge from the gendered experiences shared by the nursing students: Gender consciousness awakening and thus maintaining masculinity, and male advantage in the learning environments. The results identify the specific gendered experiences of nursing students, providing implications for future nursing education and counseling service. Further, this study may serve to promote an active yet gender-sensitive nursing education for training nursing professionals. Published by Elsevier Ltd.

  8. Characterizing Design Cognition of High School Students: Initial Analyses Comparing Those with and without Pre-Engineering Experiences

    Science.gov (United States)

    Wells, John; Lammi, Matthew; Gero, John; Grubbs, Michael E.; Paretti, Marie; Williams, Christopher

    2016-01-01

    Reported in this article are initial results from of a longitudinal study to characterize the design cognition and cognitive design styles of high school students with and without pre-engineering course experience over a 2-year period, and to compare them with undergraduate engineering students. The research followed a verbal protocol analysis…

  9. WE-FG-202-08: Assessment of Treatment Response Via Longitudinal Diffusion MRI On A MRI-Guided System: Initial Experience of Quantitative Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Qi, X; Yang, Y; Yang, L; Low, D; Sheng, K [UCLA, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To report our initial experience of systematic monitoring treatment response using longitudinal diffusion MR images on a Co-60 MRI-guided radiotherapy system. Methods: Four patients, including 2 head-and-necks, 1 sarcoma and 1 GBM treated on a 0.35 Tesla MRI-guided treatment system, were analyzed. For each patient, 3D TrueFISP MRIs were acquired during CT simulation and before each treatment for treatment planning and patient setup purposes respectively. Additionally, 2D diffusion-weighted MR images (DWI) were acquired weekly throughout the treatment course. The gross target volume (GTV) and brainstem (as a reference structure) were delineated on weekly 3D TrueFISP MRIs to monitor anatomy changes, the contours were then transferred onto the corresponding DWI images after fusing with the weekly TrueFISP images. The patient-specific temporal and spatial variations during the entire treatment course, such as anatomic changes, target apparent diffusion coefficient (ADC) distribution were evaluated in a longitudinal pattern. Results: Routine MRI revealed progressive soft-tissue GTV volume changes (up to 53%) for the H&N cases during the treatment course of 5–7 weeks. Within the GTV, the mean ADC values varied from −44% (ADC decrease) to +26% (ADC increase) in a week. The gradual increase of ADC value was inversely associated with target volume variation for one H&N case. The maximal changes of mean ADC values within the brainstem were 5.3% for the H&N cases. For the large size sarcoma and GBM tumors, spatial heterogeneity and temporal variations were observed through longitudinal ADC analysis. Conclusion: In addition to the superior soft-tissue visualization, the 0.35T MR system on ViewRay showed the potential to quantitatively measure the ADC values for both tumor and normal tissues. For normal tissue that is minimally affected by radiation, its ADC values are reproducible. Tumor ADC values show temporal and spatial fluctuation that can be exploited for

  10. Matching Real and Synthetic Panoramic Images Using a Variant of Geometric Hashing

    Science.gov (United States)

    Li-Chee-Ming, J.; Armenakis, C.

    2017-05-01

    This work demonstrates an approach to automatically initialize a visual model-based tracker, and recover from lost tracking, without prior camera pose information. These approaches are commonly referred to as tracking-by-detection. Previous tracking-by-detection techniques used either fiducials (i.e. landmarks or markers) or the object's texture. The main contribution of this work is the development of a tracking-by-detection algorithm that is based solely on natural geometric features. A variant of geometric hashing, a model-to-image registration algorithm, is proposed that searches for a matching panoramic image from a database of synthetic panoramic images captured in a 3D virtual environment. The approach identifies corresponding features between the matched panoramic images. The corresponding features are to be used in a photogrammetric space resection to estimate the camera pose. The experiments apply this algorithm to initialize a model-based tracker in an indoor environment using the 3D CAD model of the building.

  11. Initial performance of the COSINE-100 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Adhikari, G.; Adhikari, P. [Sejong University, Department of Physics, Seoul (Korea, Republic of); Souza, E.B. de; Jo, J.H.; Lim, K.E.; Maruyama, R.H.; Pierpoint, Z.P.; Thompson, W.G. [Yale University, Department of Physics, New Haven, CT (United States); Carlin, N. [University of Sao Paulo, Physics Institute, Sao Paulo (Brazil); Choi, S.; Joo, H.W.; Kim, S.K. [Seoul National University, Department of Physics and Astronomy, Seoul (Korea, Republic of); Choi, W.Q. [Korea Institute of Science and Technology Information, Daejeon (Korea, Republic of); Karlsruher Institut fuer Technologie (KIT), Institut fuer Experimentelle Kernphysik, Eggenstein-Leopoldshafen (Germany); Djamal, M.; Prihtiadi, H. [Bandung Institute of Technology, Department of Physics, Bandung (Indonesia); Ezeribe, A.C.; Kudryavtsev, V.A.; Lynch, W.A.; Mouton, F.; Spooner, N.J.C. [University of Sheffield, Department of Physics and Astronomy, Sheffield (United Kingdom); Ha, C.; Jeon, E.J.; Kang, W.G.; Kim, B.H.; Kim, H.; Kim, K.W.; Kim, N.Y.; Lee, H.S.; Lee, J.; Lee, M.H.; Leonard, D.S.; Olsen, S.L.; Park, H.K.; Park, K.S.; Ra, S.; Yong, S.H. [Institute for Basic Science (IBS), Center for Underground Physics, Daejeon (Korea, Republic of); Hahn, I.S. [Ewha Womans University, Department of Science Education, Seoul (Korea, Republic of); Hubbard, A.J.F. [Yale University, Department of Physics, New Haven, CT (United States); Northwestern University, Department of Physics and Astronomy, Evanston, IL (United States); Kang, W.; Rott, C. [Sungkyunkwan University, Department of Physics, Seoul (Korea, Republic of); Kauer, M. [University of Wisconsin-Madison, Department of Physics and Wisconsin IceCube Particle Astrophysics Center, Madison, WI (United States); Kim, H.J.; Lee, J.Y. [Kyungpook National University, Department of Physics, Daegu (Korea, Republic of); Kim, M.C. [Sungkyunkwan University, Department of Physics, Seoul (Korea, Republic of); Chiba University, Department of Physics, Chiba (Japan); Kim, Y.D. [Sejong University, Department of Physics, Seoul (Korea, Republic of); Institute for Basic Science (IBS), Center for Underground Physics, Daejeon (Korea, Republic of); Kim, Y.H. [Institute for Basic Science (IBS), Center for Underground Physics, Daejeon (Korea, Republic of); Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Park, H.S. [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Park, J.S. [Institute for Basic Science (IBS), Center for Underground Physics, Daejeon (Korea, Republic of); High Energy Accelerator Research Organization (KEK), Ibaraki (Japan); Pettus, W. [Yale University, Department of Physics, New Haven, CT (United States); University of Washington, Department of Physics, Center for Experimental Nuclear Physics and Astrophysics, Seattle, WA (United States); Rogers, F.R. [Yale University, Department of Physics, New Haven, CT (United States); Massachusetts Institute of Technology, Department of Physics, Cambridge, MA (United States); Scarff, A. [University of Sheffield, Department of Physics and Astronomy, Sheffield (United Kingdom); University of British Columbia, Department of Physics and Astronomy, Vancouver, BC (Canada); Yang, L. [University of Illinois at Urbana-Champaign, Department of Physics, Urbana, IL (United States)

    2018-02-15

    COSINE is a dark matter search experiment based on an array of low background NaI(Tl) crystals located at the Yangyang underground laboratory. The assembly of COSINE-100 was completed in the summer of 2016 and the detector is currently collecting physics quality data aimed at reproducing the DAMA/LIBRA experiment that reported an annual modulation signal. Stable operation has been achieved and will continue for at least 2 years. Here, we describe the design of COSINE-100, including the shielding arrangement, the configuration of the NaI(Tl) crystal detection elements, the veto systems, and the associated operational systems, and we show the current performance of the experiment. (orig.)

  12. The Role of Imagery and Experiences in the Construction of a Tourism Destination Image

    Directory of Open Access Journals (Sweden)

    Nelson Matos

    2015-06-01

    Full Text Available This paper addresses the role of imagery and tourism experiences (TEs in the construction of tourism destination image (TDI. It highlights the importance of the construct imagery at all stages of consumption, because of the intangibility that characterizes tourism and services in general. This aspect gains importance since it is impossible for tourists to experience the desired holidays prior to visitation, leading the way for imagery to become an essential element to inspire and to influence them during the decision-making process, and consumption before, during and after the experience. A conceptual model resulting from the literature review and the potential theoretical contribution of the model are discussed.

  13. Assessment of crown fire initiation and spread models in Mediterranean conifer forests by using data from field and laboratory experiments

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez y Silva, F.; Guijarro, M.; Madrigal, J.; Jiménez, E.; Molina, J.R.; Hernando, C.; Vélez, R.; Vega, J.A.

    2017-11-01

    Aims of study: To conduct the first full-scale crown fire experiment carried out in a Mediterranean conifer stand in Spain; to use different data sources to assess crown fire initiation and spread models, and to evaluate the role of convection in crown fire initiation. Area of study: The Sierra Morena mountains (Coordinates ETRS89 30N: X: 284793-285038; Y: 4218650-4218766), southern Spain, and the outdoor facilities of the Lourizán Forest Research Centre, northwestern Spain. Material and methods: The full-scale crown fire experiment was conducted in a young Pinus pinea stand. Field data were compared with data predicted using the most used crown fire spread models. A small-scale experiment was developed with Pinus pinaster trees to evaluate the role of convection in crown fire initiation. Mass loss calorimeter tests were conducted with P. pinea needles to estimate residence time of the flame, which was used to validate the crown fire spread model. Main results: The commonly used crown fire models underestimated the crown fire spread rate observed in the full-scale experiment, but the proposed new integrated approach yielded better fits. Without wind-forced convection, tree crowns did not ignite until flames from an intense surface fire contacted tree foliage. Bench-scale tests based on radiation heat flux therefore offer a limited insight to full-scale phenomena. Research highlights: Existing crown fire behaviour models may underestimate the rate of spread of crown fires in many Mediterranean ecosystems. New bench-scale methods based on flame buoyancy and more crown field experiments allowing detailed measurements of fire behaviour are needed.

  14. Assessment of crown fire initiation and spread models in Mediterranean conifer forests by using data from field and laboratory experiments

    International Nuclear Information System (INIS)

    Rodríguez y Silva, F.; Guijarro, M.; Madrigal, J.; Jiménez, E.; Molina, J.R.; Hernando, C.; Vélez, R.; Vega, J.A.

    2017-01-01

    Aims of study: To conduct the first full-scale crown fire experiment carried out in a Mediterranean conifer stand in Spain; to use different data sources to assess crown fire initiation and spread models, and to evaluate the role of convection in crown fire initiation. Area of study: The Sierra Morena mountains (Coordinates ETRS89 30N: X: 284793-285038; Y: 4218650-4218766), southern Spain, and the outdoor facilities of the Lourizán Forest Research Centre, northwestern Spain. Material and methods: The full-scale crown fire experiment was conducted in a young Pinus pinea stand. Field data were compared with data predicted using the most used crown fire spread models. A small-scale experiment was developed with Pinus pinaster trees to evaluate the role of convection in crown fire initiation. Mass loss calorimeter tests were conducted with P. pinea needles to estimate residence time of the flame, which was used to validate the crown fire spread model. Main results: The commonly used crown fire models underestimated the crown fire spread rate observed in the full-scale experiment, but the proposed new integrated approach yielded better fits. Without wind-forced convection, tree crowns did not ignite until flames from an intense surface fire contacted tree foliage. Bench-scale tests based on radiation heat flux therefore offer a limited insight to full-scale phenomena. Research highlights: Existing crown fire behaviour models may underestimate the rate of spread of crown fires in many Mediterranean ecosystems. New bench-scale methods based on flame buoyancy and more crown field experiments allowing detailed measurements of fire behaviour are needed.

  15. THE ROLE OF LANGUAGE GAME IN THE BUILDING UP OF A POLITICIAN'S IMAGE (PRAGMALINGUISTIC PERLOCUTIONARY EXPERIMENT)

    OpenAIRE

    Khanina E. A.

    2016-01-01

    The article discusses the results of the pragmalinguistic experiment. Since language game is a result of speech creative work, which manifests the individuality of a linguistic personality, the politician can intentionally use language game and thereby consciously form his attractive image. The politician, who uses different kinds of language game, makes some personal characteristics building up the portrait aspect of effective political image more distinguished and thus affects the election ...

  16. Image registration based on virtual frame sequence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H.; Ng, W.S. [Nanyang Technological University, Computer Integrated Medical Intervention Laboratory, School of Mechanical and Aerospace Engineering, Singapore (Singapore); Shi, D. (Nanyang Technological University, School of Computer Engineering, Singapore, Singpore); Wee, S.B. [Tan Tock Seng Hospital, Department of General Surgery, Singapore (Singapore)

    2007-08-15

    This paper is to propose a new framework for medical image registration with large nonrigid deformations, which still remains one of the biggest challenges for image fusion and further analysis in many medical applications. Registration problem is formulated as to recover a deformation process with the known initial state and final state. To deal with large nonlinear deformations, virtual frames are proposed to be inserted to model the deformation process. A time parameter is introduced and the deformation between consecutive frames is described with a linear affine transformation. Experiments are conducted with simple geometric deformation as well as complex deformations presented in MRI and ultrasound images. All the deformations are characterized with nonlinearity. The positive results demonstrated the effectiveness of this algorithm. The framework proposed in this paper is feasible to register medical images with large nonlinear deformations and is especially useful for sequential images. (orig.)

  17. Evaluation of an image-based tracking workflow using a passive marker and resonant micro-coil fiducials for automatic image plane alignment in interventional MRI.

    Science.gov (United States)

    Neumann, M; Breton, E; Cuvillon, L; Pan, L; Lorenz, C H; de Mathelin, M

    2012-01-01

    In this paper, an original workflow is presented for MR image plane alignment based on tracking in real-time MR images. A test device consisting of two resonant micro-coils and a passive marker is proposed for detection using image-based algorithms. Micro-coils allow for automated initialization of the object detection in dedicated low flip angle projection images; then the passive marker is tracked in clinical real-time MR images, with alternation between two oblique orthogonal image planes along the test device axis; in case the passive marker is lost in real-time images, the workflow is reinitialized. The proposed workflow was designed to minimize dedicated acquisition time to a single dedicated acquisition in the ideal case (no reinitialization required). First experiments have shown promising results for test-device tracking precision, with a mean position error of 0.79 mm and a mean orientation error of 0.24°.

  18. A New 4D Imaging Method for Three-Phase Analogue Experiments in Volcanology (and Other Three-Phase Systems)

    Science.gov (United States)

    Oppenheimer, J.; Patel, K. B.; Lev, E.; Hillman, E. M. C.

    2017-12-01

    Bubbles and crystals suspended in magmas interact with each other on a small scale, which affects large-scale volcanic processes. Studying these interactions on relevant scales of time and space is a long-standing challenge. Therefore, the fundamental explanations for the behavior of bubble- and crystal-rich magmas are still largely speculative. Recent application of X-ray tomography to experiments with synthetic magmas has already improved our understanding of small-scale 4D (3D + time) phenomena. However, this technique has low imaging rates Confocally Aligned Planar Excitation (SCAPE) microscopy. This method based on laser-fluorescence has been used to image live biological processes at high speed and in 3D. It allows imaging rates of up to several hundred vps and image volumes up to 1 x 1 x 0.5 mm3, with a trade-off between speed and spatial resolution. We ran two sets of experiments with silicone oil and soda-lime glass beads of <50 µm diameter, contained within a vertical glass casing 50 x 5 x 4 mm3. We used two different bubble generation methods. In the first set of experiments, small air bubbles (< 1 mm) were introduced through a hole at the bottom of the sample and allowed to rise through a suspension with low-viscosity oil. We successfully imaged bubble rise and particle movements around the bubble. In the second set, bubbles were generated by mixing acetone into the suspension and decreasing the surface pressure to cause a phase change to gaseous acetone. This bubble generation method compared favorably with previous gum rosin-acetone experiments: they provided similar degassing behaviors, along with more control on suspension viscosity and optimal optical properties for laser transmission. Large volumes of suspended bubbles, however, interfered with the laser path. In this set, we were able to track bubble nucleation sites and nucleation rates in 4D. This promising technique allows the study of small-scale interactions in two- and three-phase systems

  19. Deflagration to detonation experiments in granular HMX

    Energy Technology Data Exchange (ETDEWEB)

    Burnside, N.J.; Son, S.F.; Asay, B.W.; Dickson, P.M.

    1998-03-01

    In this paper the authors report on continuing work involving a series of deflagration-to-detonation transition (DDT) experiments in which they study the piston-initiated DDT of heavily confined granular cyclotetramethylenetetranitramine (HMX). These experiments were designed to he useful in model development and evaluation. A main focus of these experiments is the effect of density on the DDT event. Particle size distribution and morphology are carefully characterized. In this paper they present recent surface area analysis. Earlier studies demonstrated extensive fracturing and agglomeration in samples at densities as low as 75% TMD as evidenced by dramatic decreases in particle size distribution due to mild stimulus. This is qualitatively confirmed with SEM images and quantitatively studied with gas absorption surface area analysis. Also, in this paper they present initial results using a microwave interferometer technique. Dynamic calibration of the technique was performed, a 35 GHz signal is used to increase resolution, and the system has been designed to be inexpensive for repeated experiments. The distance to where deformation of the inner wall begins for various densities is reported. This result is compared with the microwave interferometer measurements.

  20. Automated detection of analyzable metaphase chromosome cells depicted on scanned digital microscopic images

    Science.gov (United States)

    Qiu, Yuchen; Wang, Xingwei; Chen, Xiaodong; Li, Yuhua; Liu, Hong; Li, Shibo; Zheng, Bin

    2010-02-01

    Visually searching for analyzable metaphase chromosome cells under microscopes is quite time-consuming and difficult. To improve detection efficiency, consistency, and diagnostic accuracy, an automated microscopic image scanning system was developed and tested to directly acquire digital images with sufficient spatial resolution for clinical diagnosis. A computer-aided detection (CAD) scheme was also developed and integrated into the image scanning system to search for and detect the regions of interest (ROI) that contain analyzable metaphase chromosome cells in the large volume of scanned images acquired from one specimen. Thus, the cytogeneticists only need to observe and interpret the limited number of ROIs. In this study, the high-resolution microscopic image scanning and CAD performance was investigated and evaluated using nine sets of images scanned from either bone marrow (three) or blood (six) specimens for diagnosis of leukemia. The automated CAD-selection results were compared with the visual selection. In the experiment, the cytogeneticists first visually searched for the analyzable metaphase chromosome cells from specimens under microscopes. The specimens were also automated scanned and followed by applying the CAD scheme to detect and save ROIs containing analyzable cells while deleting the others. The automated selected ROIs were then examined by a panel of three cytogeneticists. From the scanned images, CAD selected more analyzable cells than initially visual examinations of the cytogeneticists in both blood and bone marrow specimens. In general, CAD had higher performance in analyzing blood specimens. Even in three bone marrow specimens, CAD selected 50, 22, 9 ROIs, respectively. Except matching with the initially visual selection of 9, 7, and 5 analyzable cells in these three specimens, the cytogeneticists also selected 41, 15 and 4 new analyzable cells, which were missed in initially visual searching. This experiment showed the feasibility of

  1. Initial experience with megavoltage (MV) CT guidance for daily prostate alignments

    International Nuclear Information System (INIS)

    Langen, Katja M.; Zhang Yashan; Andrews, Rhonda D.; Hurley, Monica E.; Meeks, Sanford L.; Poole, Darrell O.; Willoughby, Twyla R.; Kupelian, Patrick A.

    2005-01-01

    Purpose: The on-board megavoltage (MV) computed tomography (CT) capabilities of a TomoTherapy Hi*ART unit were used to obtain daily MVCT images of prostate cancer patients. For patient alignment the daily MVCT image needs to be registered with the planning CT image to calculate couch shifts. Three manual techniques of registering the MVCT images with the planning kilovoltage (kV) CT images were evaluated. The techniques are based on visual alignment of (1) fiducial prostate markers (2) CT anatomy, and (3) kVCT contours. Methods and Materials: One hundred and twelve alignments from 3 patients were available for analysis. The radiation therapists visually registered the MVCT images with the planning kVCT images based on fiducial markers for actual patient alignment. Retrospectively, the therapists registered each image set using anatomy and contour-based techniques. In addition to the therapists, a physician retrospectively registered each image set based on each of the three techniques. For each MVCT to kVCT image pair a reference alignment was computed from the center-of-mass (COM) of the three fiducial markers. All registration results were compared with these reference alignments. The physician's image registrations were compared with the radiation therapists' registrations to assess the user variability of the different techniques. Results: The marker-based registration results agree best with the reference alignments, while the contour-based registrations show the least degree of agreement. Using anatomy and contour-based registrations, the radiation therapist's alignments differed by ≥ 3 mm from the reference alignments in 24%, 33%, and 3% and 55%, 48%, and 21% of all registrations in the anterior-posterior, superior-inferior, and lateral directions, respectively. The respective values for the marker-based alignments were 3%, 6%, and 3%. The physician's registrations showed the same general trend. The marker-based registrations showed the least amount of

  2. Road Extraction and Car Detection from Aerial Image Using Intensity and Color

    Directory of Open Access Journals (Sweden)

    Vahid Ghods

    2011-07-01

    Full Text Available In this paper a new automatic approach to road extraction from aerial images is proposed. The initialization strategies are based on the intensity, color, and Hough transform. After road elements extraction, chain codes are calculated. In the last step, using shadow, cars on the roads are detected. We implemented our method on the 25 images from "Google Earth" database. The experiments show an increase in both the completeness and the quality indexes for the extracted road.

  3. Real-time virtual sonography (RVS)-guided vacuum-assisted breast biopsy for lesions initially detected with breast MRI.

    Science.gov (United States)

    Uematsu, Takayoshi

    2013-12-01

    To report on our initial experiences with a new method of real-time virtual sonography (RVS)-guided 11-gauge vacuum-assisted breast biopsy for lesions that were initially detected with breast MRI. RVS-guided 11-gauge vacuum-assisted biopsy is performed when a lesion with suspicious characteristics is initially detected with breast MRI and is occult on mammography, sonography, and physical examination. Live sonographic images were co-registered to the previously loaded second-look spine contrast-enhanced breast MRI volume data to correlate the sonography and MR images. Six lesions were examined in six consecutive patients scheduled to undergo RVS-guided 11-gauge vacuum-assisted biopsy. One patient was removed from the study because of non-visualization of the lesion in the second-look spine contrast-enhanced breast MRI. Five patients with non-mass enhancement lesions were biopsied. The lesions ranged in size from 9 to 13 mm (mean 11 mm). The average procedural time, including the sonography and MR image co-registration time, was 25 min. All biopsies resulted in tissue retrieval. One was fibroadenomatous nodules, and those of four were fibrocystic changes. There were no complications during or after the procedures. RVS-guided 11-gauge vacuum-assisted breast biopsies provide a safe and effective method for the examination of suspicious lesions initially detected with MRI.

  4. Magnetic resonance imaging in pediatric neurological disease

    International Nuclear Information System (INIS)

    Tsukiyama, Takashi; Nishimoto, Hiroshi; Fujioka, Mutsuhisa; Aihara, Toshinori; Tanaka, Osamu.

    1986-01-01

    In this paper, we summarize our initial experience with Magnetic Resonance Imaging(MRI) in the evaluation of pediatric neurological disease. 17 children between the ages of 2 month and 8.5 year have been examined with MRI. All subjects tolerated the MRI procedure well, although sedation was necessary for young children. Result as follows : (1) MRI does not utilize ionising radiation to produce an image. (2) MRI images more clearly demonstrate cerebral gray and white matter than X-ray CT. (3) Compared with X-ray CT, MRI proved to be advantageous in detection and characterization of the pathology, especially when the abnormality was located along the posterior fossa and spinal canal. It is suggested that these nature of MRI makes it the ideal diagnostic method for children. (author)

  5. Location of Rotator Cuff Tear Initiation: A Magnetic Resonance Imaging Study of 191 Shoulders.

    Science.gov (United States)

    Jeong, Jeung Yeol; Min, Seul Ki; Park, Keun Min; Park, Yong Bok; Han, Kwang Joon; Yoo, Jae Chul

    2018-03-01

    Degenerative rotator cuff tears (RCTs) are generally thought to originate at the anterior margin of the supraspinatus tendon. However, a recent ultrasonography study suggested that they might originate more posteriorly than originally thought, perhaps even from the isolated infraspinatus (ISP) tendon, and propagate toward the anterior supraspinatus. Hypothesis/Purpose: It was hypothesized that this finding could be reproduced with magnetic resonance imaging (MRI). The purpose was to determine the most common location of degenerative RCTs by using 3-dimensional multiplanar MRI reconstruction. It was assumed that the location of the partial-thickness tears would identify the area of the initiation of full-thickness tears. Cross-sectional study; Level of evidence, 3. A retrospective analysis was conducted including 245 patients who had RCTs (nearly full- or partial-thickness tears) at the outpatient department between January 2011 and December 2013. RCTs were measured on 3-dimensional multiplanar reconstruction MRI with OsiriX software. The width and distance from the biceps tendon to the anterior margin of the tear were measured on T2-weighted sagittal images. In a spreadsheet, columns of consecutive numbers represented the size of each tear (anteroposterior width) and their locations with respect to the biceps brachii tendon. Data were pooled to graphically represent the width and location of all tears. Frequency histograms of the columns were made to visualize the distribution of tears. The tears were divided into 2 groups based on width (group A, location related to size. The mean width of all RCTs was 11.9 ± 4.1 mm, and the mean length was 11.1 ± 5.0 mm. Histograms showed the most common location of origin to be 9 to 10 mm posterior to the biceps tendon. The histograms of groups A and B showed similar tear location distributions, indicating that the region approximately 10 mm posterior to the biceps tendon is the most common site of tear initiation. These

  6. Independence and Interdependence: An Analysis of Pre-Service Candidates' Use of Focused Assignments on an Electronic Discussion Forum during the Initial Field Experience

    Science.gov (United States)

    Fisch, Audrey A.; Bennett, Deborah J.

    2011-01-01

    This article describes a case study using an electronic learning platform for creating an interactive learning community through asynchronous discussion to enhance the initial field experience of secondary math and English teacher candidates enrolled in Field Experience. We identified three problems with the field experience course--lack of…

  7. GOTCHA experience report: three-dimensional SAR imaging with complete circular apertures

    Science.gov (United States)

    Ertin, Emre; Austin, Christian D.; Sharma, Samir; Moses, Randolph L.; Potter, Lee C.

    2007-04-01

    We study circular synthetic aperture radar (CSAR) systems collecting radar backscatter measurements over a complete circular aperture of 360 degrees. This study is motivated by the GOTCHA CSAR data collection experiment conducted by the Air Force Research Laboratory (AFRL). Circular SAR provides wide-angle information about the anisotropic reflectivity of the scattering centers in the scene, and also provides three dimensional information about the location of the scattering centers due to a non planar collection geometry. Three dimensional imaging results with single pass circular SAR data reveals that the 3D resolution of the system is poor due to the limited persistence of the reflectors in the scene. We present results on polarimetric processing of CSAR data and illustrate reasoning of three dimensional shape from multi-view layover using prior information about target scattering mechanisms. Next, we discuss processing of multipass (CSAR) data and present volumetric imaging results with IFSAR and three dimensional backprojection techniques on the GOTCHA data set. We observe that the volumetric imaging with GOTCHA data is degraded by aliasing and high sidelobes due to nonlinear flightpaths and sparse and unequal sampling in elevation. We conclude with a model based technique that resolves target features and enhances the volumetric imagery by extrapolating the phase history data using the estimated model.

  8. THE COSMIC INFRARED BACKGROUND EXPERIMENT (CIBER): THE WIDE-FIELD IMAGERS

    Energy Technology Data Exchange (ETDEWEB)

    Bock, J.; Battle, J. [Jet Propulsion Laboratory (JPL), National Aeronautics and Space Administration (NASA), Pasadena, CA 91109 (United States); Sullivan, I. [Department of Physics, University of Washington, Seattle, WA 98195 (United States); Arai, T.; Matsumoto, T.; Matsuura, S.; Tsumura, K. [Department of Space Astronomy and Astrophysics, Institute of Space and Astronautical Science (ISAS), Japan Aerospace Exploration Agency (JAXA), Sagamihara, Kanagawa 252-5210 (Japan); Cooray, A.; Mitchell-Wynne, K.; Smidt, J. [Center for Cosmology, University of California, Irvine, CA 92697 (United States); Hristov, V.; Lam, A. C.; Levenson, L. R.; Mason, P. [Department of Physics, Mathematics and Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); Keating, B.; Renbarger, T. [Department of Physics, University of California, San Diego, San Diego, CA 92093 (United States); Kim, M. G. [Department of Physics and Astronomy, Seoul National University, Seoul 151-742 (Korea, Republic of); Lee, D. H. [Institute of Astronomy and Astrophysics, Academia Sinica, National Taiwan University, Taipei 10617, Taiwan (China); Nam, U. W. [Korea Astronomy and Space Science Institute (KASI), Daejeon 305-348 (Korea, Republic of); Suzuki, K. [Instrument Development Group of Technical Center, Nagoya University, Nagoya, Aichi 464-8602 (Japan); and others

    2013-08-15

    We have developed and characterized an imaging instrument to measure the spatial properties of the diffuse near-infrared extragalactic background light (EBL) in a search for fluctuations from z > 6 galaxies during the epoch of reionization. The instrument is part of the Cosmic Infrared Background Experiment (CIBER), designed to observe the EBL above Earth's atmosphere during a suborbital sounding rocket flight. The imaging instrument incorporates a 2 Degree-Sign Multiplication-Sign 2 Degree-Sign field of view to measure fluctuations over the predicted peak of the spatial power spectrum at 10 arcmin, and 7'' Multiplication-Sign 7'' pixels, to remove lower redshift galaxies to a depth sufficient to reduce the low-redshift galaxy clustering foreground below instrumental sensitivity. The imaging instrument employs two cameras with {Delta}{lambda}/{lambda} {approx} 0.5 bandpasses centered at 1.1 {mu}m and 1.6 {mu}m to spectrally discriminate reionization extragalactic background fluctuations from local foreground fluctuations. CIBER operates at wavelengths where the electromagnetic spectrum of the reionization extragalactic background is thought to peak, and complements fluctuation measurements by AKARI and Spitzer at longer wavelengths. We have characterized the instrument in the laboratory, including measurements of the sensitivity, flat-field response, stray light performance, and noise properties. Several modifications were made to the instrument following a first flight in 2009 February. The instrument performed to specifications in three subsequent flights, and the scientific data are now being analyzed.

  9. Image analysis to measure sorting and stratification applied to sand-gravel experiments

    OpenAIRE

    Orrú, C.

    2016-01-01

    The main objective of this project is to develop new measuring techniques for providing detailed data on sediment sorting suitable for sand-gravel laboratory experiments. Such data will be of aid in obtaining new insights on sorting mechanisms and improving prediction capabilities of morphodynamic models. Two measuring techniques have been developed. The first technique is aimed at measuring the size stratification of a sand-gravel deposit through combining image analysis and a sediment remov...

  10. Compartmental analysis, imaging techniques and population pharmacokinetic. Experiences at CENTIS

    International Nuclear Information System (INIS)

    Hernández, Ignacio; León, Mariela; Leyva, Rene; Castro, Yusniel; Ayra, Fernando E.

    2016-01-01

    Introduction: In pharmacokinetic evaluation small rodents are used in a large extend. Traditional pharmacokinetic evaluations by the two steps approach can be replaced by the sparse data design which may also represent a complicated situation to evaluate satisfactorily from the statistical point of view. In this presentation different situations of sparse data sampling are analyzed based on practical consideration. Non linear mixed effect model was selected in order to estimate pharmacokinetic parameters in simulated data from real experimental results using blood sampling and imaging procedures. Materials and methods: Different scenarios representing several experimental designs of incomplete individual profiles were evaluated. Data sets were simulated based on real data from previous experiments. In all cases three to five blood samples were considered per time point. A combination of compartmental analysis with tumor uptake obtained by gammagraphy of radiolabeled drugs is also evaluated.All pharmacokinetic profiles were analyzed by means of MONOLIX software version 4.2.3. Results: All sampling schedules yield the same results when computed using the MONOLIX software and the SAEM algorithm. Population and individual pharmacokinetic parameters were accurately estimated with three or five determination per sampling point. According with the used methodology and software tool, it can be an expected result, but demonstrating the method performance in such situations, allow us to select a more flexible design using a very small number of animals in preclinical research. The combination with imaging procedures also allows us to construct a completely structured compartmental analysis. Results of real experiments are presented demonstrating the versatility of used methodology in different evaluations. The same sampling approach can be considered in phase I or II clinical trials. (author)

  11. Initial clinical experience with spiral CT angiography in the abdomen

    International Nuclear Information System (INIS)

    Gaa, J.; Stehling, M.K.; Costello, P.

    1993-01-01

    The latest developments in modern CT instruments, offering scanning times of a second, opened up new possibilities in CT imaging in combination with the spiral technique. The data set normally taken with single-breath-hold technique is free of respiratory artefacts and thus is a good basis for accurate 3D image reconstruction. Spiral CTA allows a non-invasive 3D imaging of various blood vessels. Patients with abdominal aortic aneurysms of aorto-iliac bypass can be examined as outpatients within 15 minutes. (orig.) [de

  12. Initial measurements of two- and three-dimensional ordering, waves, and plasma filamentation in the Magnetized Dusty Plasma Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Edward, E-mail: etjr@auburn.edu; Konopka, Uwe [Physics Department, Auburn University, Auburn, Alabama 36849 (United States); Merlino, Robert L. [Department of Physics and Astronomy, The University of Iowa, Iowa City, Iowa 52242 (United States); Rosenberg, Marlene [Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, California 92093 (United States)

    2016-05-15

    The Magnetized Dusty Plasma Experiment at Auburn University has been operational for over one year. In that time, a number of experiments have been performed at magnetic fields up to B = 2.5 T to explore the interaction between magnetized plasmas and charged, micron-sized dust particles. This paper reports on the initial results from studies of: (a) the formation of imposed, ordered structures, (b) the properties of dust wave waves in a rotating frame, and (c) the generation of plasma filaments.

  13. With the Advent of Tomosynthesis in the Workup of Mammographic Abnormality, is Spot Compression Mammography Now Obsolete? An Initial Clinical Experience.

    Science.gov (United States)

    Ni Mhuircheartaigh, Neasa; Coffey, Louise; Fleming, Hannah; O' Doherty, Ann; McNally, Sorcha

    2017-09-01

    To determine if the routine use of spot compression mammography is now obsolete in the assessment of screen detected masses, asymmetries and architectural distortion since the availability of digital breast tomosynthesis. We introduced breast tomosynthesis in the workup of screen detected abnormalities in our screening center in January 2015. During an initial learning period with tomosynthesis standard spot compression views were also performed. Three consultant breast radiologists retrospectively reviewed all screening mammograms recalled for assessment over the first 6-month period. We assessed retrospectively whether there was any additional diagnostic information obtained from spot compression views not already apparent on tomography. All cases were also reviewed for any additional lesions detected by tomosynthesis, not detected on routine 2-view screening mammography. 548 women screened with standard 2-view digital screening mammography were recalled for assessment in the selected period and a total of 565 lesions were assessed. 341 lesions were assessed by both tomosynthesis and routine spot compression mammography. The spot compression view was considered more helpful than tomosynthesis in only one patient. This was because the breast was inadequately positioned for tomosynthesis and the area in question was not adequately imaged. Apart from this technical error there was no asymmetry, distortion or mass where spot compression provided more diagnostic information than tomosynthesis alone. We detected three additional cancers on tomosynthesis, not detected by routine screening mammography. From our initial experience with tomosynthesis we conclude that spot compression mammography is now obsolete in the assessment of screen detected masses, asymmetries and distortions where tomosynthesis is available. © 2017 Wiley Periodicals, Inc.

  14. Transfer and conversion of images based on EIT in atom vapor.

    Science.gov (United States)

    Cao, Mingtao; Zhang, Liyun; Yu, Ya; Ye, Fengjuan; Wei, Dong; Guo, Wenge; Zhang, Shougang; Gao, Hong; Li, Fuli

    2014-05-01

    Transfer and conversion of images between different wavelengths or polarization has significant applications in optical communication and quantum information processing. We demonstrated the transfer of images based on electromagnetically induced transparency (EIT) in a rubidium vapor cell. In experiments, a 2D image generated by a spatial light modulator is used as a coupling field, and a plane wave served as a signal field. We found that the image carried by coupling field could be transferred to that carried by signal field, and the spatial patterns of transferred image are much better than that of the initial image. It also could be much smaller than that determined by the diffraction limit of the optical system. We also studied the subdiffraction propagation for the transferred image. Our results may have applications in quantum interference lithography and coherent Raman spectroscopy.

  15. Evaluating the influence of initial magnetization conditions on extracted exchange parameters in NMR relaxation experiments: applications to CPMG and CEST

    Energy Technology Data Exchange (ETDEWEB)

    Yuwen, Tairan; Sekhar, Ashok; Kay, Lewis E., E-mail: kay@pound.med.utoronto.ca [The University of Toronto, Departments of Molecular Genetics, Biochemistry and Chemistry (Canada)

    2016-08-15

    Transient excursions of native protein states to functionally relevant higher energy conformations often occur on the μs–ms timescale. NMR spectroscopy has emerged as an important tool to probe such processes using techniques such as Carr–Purcell–Meiboom–Gill (CPMG) relaxation dispersion and Chemical Exchange Saturation Transfer (CEST). The extraction of kinetic and structural parameters from these measurements is predicated upon mathematical modeling of the resulting relaxation profiles, which in turn relies on knowledge of the initial magnetization conditions at the start of the CPMG/CEST relaxation elements in these experiments. Most fitting programs simply assume initial magnetization conditions that are given by equilibrium populations, which may be incorrect in certain implementations of experiments. In this study we have quantified the systematic errors in extracted parameters that are generated from analyses of CPMG and CEST experiments using incorrect initial boundary conditions. We find that the errors in exchange rates (k{sub ex}) and populations (p{sub E}) are typically small (<10 %) and thus can be safely ignored in most cases. However, errors become larger and cannot be fully neglected (20–40 %) as k{sub ex} falls near the lower limit of each method or when short CPMG/CEST relaxation elements are used in these experiments. The source of the errors can be rationalized and their magnitude given by a simple functional form. Despite the fact that errors tend to be small, it is recommended that the correct boundary conditions be implemented in fitting programs so as to obtain as robust estimates of exchange parameters as possible.

  16. Initial Encounters : The Lived Experiences of Buyers

    NARCIS (Netherlands)

    G. Wright; J.J. Dekker

    2012-01-01

    The initial encounter between a buyer and a seller has received much attention among practitioners. The first time a buyer interacts with a seller is thought to be highly influential. The premise is that buyers form an opinion during this first encounter, or even the first minutes of this encounter.

  17. Predicting Visible Image Degradation by Colour Image Difference Formulae

    Institute of Scientific and Technical Information of China (English)

    Eriko Bando; Jon Y. Hardeberg; David Connah; Ivar Farup

    2004-01-01

    It carried out a CRT monitor based psychophysical experiment to investigate the quality of three colour image difference metrics, the CIEAE ab equation, the iCAM and the S-CIELAB metrics. Six original images were reproduced through six gamut mapping algorithms for the observer experiment. The result indicates that the colour image difference calculated by each metric does not directly relate to perceived image difference.

  18. Pore Formation and Mobility Investigation (PFMI): Concept, Hardware Development and Initial Analysis of Experiments

    Science.gov (United States)

    Grugel, Richard N.

    2004-01-01

    Porosity in the form of "bubbles and pipes" can occur during controlled directional solidification processing of metal alloys. This is a consequence that 1) precludes obtaining any meaningful scientific results and 2) is detrimental to desired material properties. Unfortunately, several Microgravity experiments have been compromised by porosity. The intent of the PFMI investigation is to conduct a systematic effort directed towards understanding porosity formation and mobility during controlled directional solidification (DS) in a microgravity environment. PFMI uses a pure transparent material, succinonitrile (SCN), as well as SCN "alloyed" with water, in conjunction with a translating temperature gradient stage so that direct observation and recording of pore generation and mobility can be made. PFMI is investigating the role of thermocapillary forces and temperature gradients in affecting bubble dynamics as well as other solidification processes in a microgravity Environment. This presentation will cover the concept, hardware development, operations, and the initial results from experiments conducted aboard the International Space Station. .

  19. Use of Iodine-based contrast media in digital full-field mammography - initial experience

    International Nuclear Information System (INIS)

    Diekmann, F.; Diekmann, S.; Taupitz, M.; Bick, U.; Winzer, K.-J.; Huettner, C.; Muller, S.; Jeunehomme, F.; Hamm, B.

    2003-01-01

    Aim: To investigate the use of iodine-based contrast media in digital full-field mammography. Methods: After performing initial phantom studies, seven patients underwent digital mammography (Senographe 2000D, GE Medical Systems, Milwaukee, USA) using a specially filtered beam before as well as 60, 120, and 180 seconds after injection of 80 ml of iodine contrast medium (Ultravist 370, Schering AG, Germany). The precontrast mammograms were then subtracted from the postcontrast mammograms and the resulting images compared with a contrast-enhanced dynamic MRI study, performed on all women. Results: Contrast medium accumulation within the tumors was visualized with a good quality in all cases. The conditions under which successful contrast-enhanced digital mammography can be performed were determined in phantom studies. Conclusions: Contrast-enhanced digital mammography has a potential for improving the visualization of breast tumors in mammography using special beam filtering, adjusted X-ray parameters, proper timing, and suitable subtraction software. (orig.) [de

  20. Phantom experiments using soft-prior regularization EIT for breast cancer imaging.

    Science.gov (United States)

    Murphy, Ethan K; Mahara, Aditya; Wu, Xiaotian; Halter, Ryan J

    2017-06-01

    A soft-prior regularization (SR) electrical impedance tomography (EIT) technique for breast cancer imaging is described, which shows an ability to accurately reconstruct tumor/inclusion conductivity values within a dense breast model investigated using a cylindrical and a breast-shaped tank. The SR-EIT method relies on knowing the spatial location of a suspicious lesion initially detected from a second imaging modality. Standard approaches (using Laplace smoothing and total variation regularization) without prior structural information are unable to accurately reconstruct or detect the tumors. The soft-prior approach represents a very significant improvement to these standard approaches, and has the potential to improve conventional imaging techniques, such as automated whole breast ultrasound (AWB-US), by providing electrical property information of suspicious lesions to improve AWB-US's ability to discriminate benign from cancerous lesions. Specifically, the best soft-regularization technique found average absolute tumor/inclusion errors of 0.015 S m -1 for the cylindrical test and 0.055 S m -1 and 0.080 S m -1 for the breast-shaped tank for 1.8 cm and 2.5 cm inclusions, respectively. The standard approaches were statistically unable to distinguish the tumor from the mammary gland tissue. An analysis of false tumors (benign suspicious lesions) provides extra insight into the potential and challenges EIT has for providing clinically relevant information. The ability to obtain accurate conductivity values of a suspicious lesion (>1.8 cm) detected from another modality (e.g. AWB-US) could significantly reduce false positives and result in a clinically important technology.

  1. Small animal simultaneous PET/MRI: initial experiences in a 9.4 T microMRI

    Energy Technology Data Exchange (ETDEWEB)

    Maramraju, Sri Harsha; Ravindranath, Bosky; Vaska, Paul; Schlyer, David J [Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY (United States); Smith, S David; Schulz, Daniela [Medical Department, Brookhaven National Laboratory, Upton, NY (United States); Junnarkar, Sachin S; Rescia, Sergio [Instrumentation Division, Brookhaven National Laboratory, Upton, NY (United States); Stoll, Sean; Purschke, Martin L; Woody, Craig L [Physics Department, Brookhaven National Laboratory, Upton, NY (United States); Southekal, Sudeepti [Brigham and Women' s Hospital, Boston, MA (United States); Pratte, Jean-Francois, E-mail: schlyer@bnl.gov [Universite de Sherbrooke, Sherbrooke, Quebec (Canada)

    2011-04-21

    We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 x 8 array of lutetium oxyorthosilicate crystals (2.22 x 2.22 x 5 mm{sup 3}) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [{sup 11}C]raclopride and 2-deoxy-2-[{sup 18}F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.

  2. The brain imaging data structure, a format for organizing and describing outputs of neuroimaging experiments.

    Science.gov (United States)

    Gorgolewski, Krzysztof J; Auer, Tibor; Calhoun, Vince D; Craddock, R Cameron; Das, Samir; Duff, Eugene P; Flandin, Guillaume; Ghosh, Satrajit S; Glatard, Tristan; Halchenko, Yaroslav O; Handwerker, Daniel A; Hanke, Michael; Keator, David; Li, Xiangrui; Michael, Zachary; Maumet, Camille; Nichols, B Nolan; Nichols, Thomas E; Pellman, John; Poline, Jean-Baptiste; Rokem, Ariel; Schaefer, Gunnar; Sochat, Vanessa; Triplett, William; Turner, Jessica A; Varoquaux, Gaël; Poldrack, Russell A

    2016-06-21

    The development of magnetic resonance imaging (MRI) techniques has defined modern neuroimaging. Since its inception, tens of thousands of studies using techniques such as functional MRI and diffusion weighted imaging have allowed for the non-invasive study of the brain. Despite the fact that MRI is routinely used to obtain data for neuroscience research, there has been no widely adopted standard for organizing and describing the data collected in an imaging experiment. This renders sharing and reusing data (within or between labs) difficult if not impossible and unnecessarily complicates the application of automatic pipelines and quality assurance protocols. To solve this problem, we have developed the Brain Imaging Data Structure (BIDS), a standard for organizing and describing MRI datasets. The BIDS standard uses file formats compatible with existing software, unifies the majority of practices already common in the field, and captures the metadata necessary for most common data processing operations.

  3. Imaging of patients with hippocampal sclerosis at 7 Tesla: initial results.

    Science.gov (United States)

    Breyer, Tobias; Wanke, Isabel; Maderwald, Stefan; Woermann, Friedrich G; Kraff, Oliver; Theysohn, Jens M; Ebner, Alois; Forsting, Michael; Ladd, Mark E; Schlamann, Marc

    2010-04-01

    Focal epilepsies potentially can be cured by neurosurgery; other treatment options usually remain symptomatic. High-resolution magnetic resonance (MR) imaging is the central imaging strategy in the evaluation of focal epilepsy. The most common substrate of temporal epilepsies is hippocampal sclerosis (HS), which cannot always be sufficiently characterized with current MR field strengths. Therefore, the purpose of our study was to demonstrate the feasibility of high-resolution MR imaging at 7 Tesla in patients with focal epilepsy resulting from a HS and to improve image resolution at 7 Tesla in patients with HS. Six patients with known HS were investigated with T1-, T2-, T2(*)-, and fluid-attenuated inversion recovery-weighted sequences at 7 Tesla with an eight-channel transmit-receive head coil. Total imaging time did not exceed 90 minutes per patient. High-resolution imaging at 7 Tesla is feasible and reveals high resolution of intrahippocampal structures in vivo. HS was confirmed in all patients. The maximum non-interpolated in-plane resolution reached 0.2 x 0.2 mm(2) in T2(*)-weighted images. The increased susceptibility effects at 7 Tesla revealed identification of intrahippocampal structures in more detail than at 1.5 Tesla, but otherwise led to stronger artifacts. Imaging revealed regional differences in hippocampal atrophy between patients. The scan volume was limited because of specific absorption rate restrictions, scanning time was reasonable. High-resolution imaging at 7 Tesla is promising in presurgical epilepsy imaging. "New" contrasts may further improve detection of even very small intrahippocampal structural changes. Therefore, further investigations will be necessary to demonstrate the potential benefit for presurgical selection of patients with various lesion patterns in mesial temporal epilepsies resulting from a unilateral HS. Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved.

  4. Initial clinical experience with frameless radiosurgery for patients with intracranial metastases

    International Nuclear Information System (INIS)

    Kamath, Reena; Ryken, Timothy C.; Meeks, Sanford L.; Pennington, Edward C.; Ritchie, Justine; Buatti, John M.

    2005-01-01

    Purpose: To review the initial clinical experience with frameless stereotactic radiosurgery (SRS) for treating intracranial metastatic disease. Methods and Materials: Sixty-four patients received frameless SRS for intracranial metastatic disease. Minimum follow-up was 6 months with none lost to follow-up. Patients had a median of 2 metastases and a maximum of 4. The median number of isocenters was 2 with median arcs of 10 and median dose of 17.5 Gy. Thirteen patients were treated for progressive/recurrent disease after surgical resection or whole brain radiotherapy (WBRT). Fifty-one patients were treated with frameless SRS as an an adjunct to initial treatment. Of the total treated, 17 were treated with SRS alone, 20 were treated with WBRT plus SRS, 16 were treated with surgical resection plus SRS, and the remaining 11 were treated with surgical resection plus WBRT plus SRS. Results: With a median actuarial follow-up period of 8.2 months, ultimate local control was 88%. The median time to progression was 8.1 months. The median overall survival was 8.7 months. Of the 17 patients treated with SRS alone, 86% had ultimate local control with mean overall survival of 7.1 months. Of the 13 patients who received surgical resection plus SRS without WBRT as primary treatment, there was 85% ultimate local control with an overall survival of 10.3 months. Three patients treated with initial surgery alone had recurrence treated with SRS 2-3 months after resection. All these patients obtained local control and median survival was >10 months. Of the 13 patients who received WBRT followed by SRS as boost treatment, 92% had local control and mean overall survival was 7.3 months. Of 7 patients who received SRS after recurrence after WBRT, 100% had local control with median survival of 8.2 months. For 8 patients who received surgery followed by WBRT and SRS, local control was 50%; however, ultimate intracranial control was achieved in 7 of 8 patients with repeat SRS and surgical

  5. Preparation, installation, and calibration of a 152-fiber imaging experiment at the Nevada Test Site

    International Nuclear Information System (INIS)

    Thayer, D.R.; Lyons, P.B.; Looney, L.D.; Manning, J.P.; Malone, R.M.

    1981-01-01

    Fiber-optic transmission lines are being used with increasing frequency in the demanding environment of nuclear device diagnostic tests at the Nevada Test Site. Previous reports have described diagnostic experiments that utilize properties of fiber-optic cables to provide capabilities that are extremely difficult to obtain with coaxial cable systems. This paper describes an imaging experiment conducted during the last quarter of 1980 at the Nevada Test Site involving 152 approx. 0.6-km long GI fibers in 18 cables. An imager cell sensitive to neutron and gamma radiation was located at approx. 8 m from the source. Individual elements of the fluor were coupled by approx. 10 m PCS fibers (for radiation damage resistance) to the GI fibers used for the uphole and surface lines to the detector station. Light from the imager cell in a 9-nm band, centered at 540 nm, was detected by photomultipliers and the electrical signals then recorded on oscilloscopes. Overall system bandwidth, including the fluor, was approx. 80 MHz. Due to the complexity of the experiment and the conditions associated with field testing, the PCS and GI fibers were cut and terminated under laboratory shop conditions prior to installation at the field site. Procedures used for quality assurance of the fiber assemblies as well as procedures used in checking fiber throughput during installation are described. The application of a large star coupler (5 input x 200 output fibers) used for system time and amplitude calibration and an attempt to shutter fibers with neutrons for a multiplexing application are also discussed

  6. "Afterlife experiment": use of MALDI-MS and SIMS imaging for the study of the nitrogen cycle within plants.

    Science.gov (United States)

    Seaman, Callie; Flinders, Bryn; Eijkel, Gert; Heeren, Ron M A; Bricklebank, Neil; Clench, Malcolm R

    2014-10-21

    As part of a project to demonstrate the science of decay, a series of mass spectrometry imaging experiments were performed. The aim was to demonstrate that decay and decomposition are only part of the story and to show pictorially that atoms and molecules from dead plants and animals are incorporated into new life. Radish plants (Raphanus sativus) were grown hydroponically using a nutrient system containing (15)N KNO3 (98% labeled) as the only source of nitrogen. Plants were cropped and left to ferment in water for 2 weeks to create a radish "tea", which was used as a source of nitrogen for radish grown in a second hydroponics experiment. After 5 weeks of growth, the radish plants were harvested and cryosectioned, and sections were imaged by positive-ion MALDI and SIMS mass spectrometry imaging. The presence of labeled species in the plants grown using (15)N KNO3 as nutrient and those grown from the radish "tea" was readily discernible. The uptake of (15)N into a number of identifiable metabolites has been studied by MALDI-MS and SIMS imaging.

  7. Raman spectra of long chain hydrocarbons: anharmonic calculations, experiment and implications for imaging of biomembranes.

    Science.gov (United States)

    Šebek, Jiří; Pele, Liat; Potma, Eric O; Gerber, R Benny

    2011-07-28

    First-principles anharmonic vibrational calculations are carried out for the Raman spectrum of the C-H stretching bands in dodecane, and for the C-D bands in the deuterated molecule. The calculations use the Vibrational Self-Consistent Field (VSCF) algorithm. The results are compared with liquid-state experiments, after smoothing the isolated-molecule sharp-line computed spectra. Very good agreement between the computed and experimental results is found for the two systems. The combined theoretical and experimental results provide insights into the spectrum, elucidating the roles of symmetric and asymmetric CH(3) and CH(2) hydrogenic stretches. This is expected to be very useful for the interpretation of spectra of long-chain hydrocarbons. The results show that anharmonic effects on the spectrum are large. On the other hand, vibrational degeneracy effects seem to be rather modest at the resolution of the experiments. The degeneracy effects may have more pronounced manifestations in higher-resolution experiments. The results show that first-principles anharmonic vibrational calculations for hydrocarbons are feasible, in good agreement with experiment, opening the way for applications to many similar systems. The results may be useful for the analysis of CARS imaging of lipids, for which dodecane is a representative molecule. It is suggested that first-principles vibrational calculations may be useful also for CARS imaging of other systems. This journal is © the Owner Societies 2011

  8. Three-dimensional facial digitization using advanced digital image correlation.

    Science.gov (United States)

    Nguyen, Hieu; Kieu, Hien; Wang, Zhaoyang; Le, Hanh N D

    2018-03-20

    Presented in this paper is an effective technique to acquire the three-dimensional (3D) digital images of the human face without the use of active lighting and artificial patterns. The technique is based on binocular stereo imaging and digital image correlation, and it includes two key steps: camera calibration and image matching. The camera calibration involves a pinhole model and a bundle-adjustment approach, and the governing equations of the 3D digitization process are described. For reliable pixel-to-pixel image matching, the skin pores and freckles or lentigines on the human face serve as the required pattern features to facilitate the process. It employs feature-matching-based initial guess, multiple subsets, iterative optimization algorithm, and reliability-guided computation path to achieve fast and accurate image matching. Experiments have been conducted to demonstrate the validity of the proposed technique. The simplicity of the approach and the affordable cost of the implementation show its practicability in scientific and engineering applications.

  9. Image-guided cryoablation for the treatment of painful musculoskeletal metastatic disease: a single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Prologo, J.D. [Emory University Hospital, Department of Radiology and Imaging Sciences, Division of Interventional Radiology and Image-Guided Medicine, Atlanta, GA (United States); Passalacqua, Matthew; Patel, Indravadan; Bohnert, Nathan [University Hospitals Case Medical Center, Department of Radiology, Cleveland, OH (United States); Corn, David J. [University Hospitals Case Medical Center, Departments of Radiology and Biomedical Engineering, Cleveland, OH (United States)

    2014-11-15

    The role of image-guided thermal ablation techniques for the nonoperative local management of painful osseous metastatic disease has expanded during recent years, and several advantages of cryoablation in this setting have emerged. The purpose of this study is to retrospectively evaluate and report a single-center experience of CT-guided percutaneous cryoablation in the setting of painful musculoskeletal metastatic disease. This study was approved by the institutional review board and is compliant with the Health Insurance Portability and Accountability Act. Electronic medical records of all patients who underwent percutaneous image-guided palliative cryoablation at our institution were reviewed (n = 61). An intent-to-treat analysis was performed. Records were reviewed for demographic data and anatomical data, primary tumor type, procedure details, and outcome - including change in analgesic requirements (expressed as morphine equivalent dosages), pain scores (utilizing the clinically implemented visual analog scale), subsequent therapies (including radiation and/or surgery), and complications during the 24 h following the procedure and at 3 months. Patients were excluded (n = 7) if data were not retrospectively identifiable at the defined time points. Fifty-four tumors were ablated in 50 patients. There were statistically significant decreases in the median VAS score and narcotic usage at both 24 h and 3 months (p < 0.000). Six patients (11 %) incurred complications related to their therapy. Two patients had no relief at 24 h, of which both reported worsened pain at 3 months. One patient had initial relief but symptom recurrence at 3 months. Four patients went on to have radiation therapy of the ablation site at some point following the procedure. CT-guided cryoablation is a safe, effective, reproducible procedural option for the nonoperative local treatment of painful musculoskeletal metastatic disease. (orig.)

  10. Image-guided cryoablation for the treatment of painful musculoskeletal metastatic disease: a single-center experience

    International Nuclear Information System (INIS)

    Prologo, J.D.; Passalacqua, Matthew; Patel, Indravadan; Bohnert, Nathan; Corn, David J.

    2014-01-01

    The role of image-guided thermal ablation techniques for the nonoperative local management of painful osseous metastatic disease has expanded during recent years, and several advantages of cryoablation in this setting have emerged. The purpose of this study is to retrospectively evaluate and report a single-center experience of CT-guided percutaneous cryoablation in the setting of painful musculoskeletal metastatic disease. This study was approved by the institutional review board and is compliant with the Health Insurance Portability and Accountability Act. Electronic medical records of all patients who underwent percutaneous image-guided palliative cryoablation at our institution were reviewed (n = 61). An intent-to-treat analysis was performed. Records were reviewed for demographic data and anatomical data, primary tumor type, procedure details, and outcome - including change in analgesic requirements (expressed as morphine equivalent dosages), pain scores (utilizing the clinically implemented visual analog scale), subsequent therapies (including radiation and/or surgery), and complications during the 24 h following the procedure and at 3 months. Patients were excluded (n = 7) if data were not retrospectively identifiable at the defined time points. Fifty-four tumors were ablated in 50 patients. There were statistically significant decreases in the median VAS score and narcotic usage at both 24 h and 3 months (p < 0.000). Six patients (11 %) incurred complications related to their therapy. Two patients had no relief at 24 h, of which both reported worsened pain at 3 months. One patient had initial relief but symptom recurrence at 3 months. Four patients went on to have radiation therapy of the ablation site at some point following the procedure. CT-guided cryoablation is a safe, effective, reproducible procedural option for the nonoperative local treatment of painful musculoskeletal metastatic disease. (orig.)

  11. Fast single image dehazing based on image fusion

    Science.gov (United States)

    Liu, Haibo; Yang, Jie; Wu, Zhengping; Zhang, Qingnian

    2015-01-01

    Images captured in foggy weather conditions often fade the colors and reduce the contrast of the observed objects. An efficient image fusion method is proposed to remove haze from a single input image. First, the initial medium transmission is estimated based on the dark channel prior. Second, the method adopts an assumption that the degradation level affected by haze of each region is the same, which is similar to the Retinex theory, and uses a simple Gaussian filter to get the coarse medium transmission. Then, pixel-level fusion is achieved between the initial medium transmission and coarse medium transmission. The proposed method can recover a high-quality haze-free image based on the physical model, and the complexity of the proposed method is only a linear function of the number of input image pixels. Experimental results demonstrate that the proposed method can allow a very fast implementation and achieve better restoration for visibility and color fidelity compared to some state-of-the-art methods.

  12. Thermoacoustic Molecular Imaging of Small Animals

    Directory of Open Access Journals (Sweden)

    Robert A. Kruger

    2003-04-01

    Full Text Available We have designed, constructed, and tested a thermoacoustic computed tomography (TCT scanner for imaging optical absorption in small animals in three dimensions. The device utilizes pulsed laser irradiation (680–1064 nm and a unique, 128-element transducer array. We quantified the isotropic spatial resolution of this scanner to be 0.35 mm. We describe a dual-wavelength subtraction technique for isolating optical dyes with TCT. Phantom experiments demonstrate that we can detect 5 fmol of a near-infrared dye (indocyanine green, ICG in a 1-ML volume using dual-wavelength subtraction. Initial TCT imaging in phantoms and in two sacrificed mice suggests that three-dimensional, optical absorption patterns in small animals can be detected with an order of magnitude better spatial resolution and an order of magnitude better low-contrast detectability in small animals when compared to fluorescence imaging or diffusion optical tomography.

  13. Preliminary experiments using light-initiated high explosive for driving thin flyer plates

    International Nuclear Information System (INIS)

    Benham, R.A.

    1980-02-01

    Light-initiated high explosive, silver acelytide - silver-nitrate (SASN), has been used to produce simulated x ray blow-off impulse loading on reentry vehicles to study the system structural response. SASN can be used to accelerate thin flyer plates to high terminal velocities which, in turn, can deliver a pressure pulse that can be tailored to the target material. This process is important for impulse tests where both structural and material response is desired. The theories used to calculate the dynamic state of the flyer plate prior to impact are summarized. Data from several experiments are presented which indicate that thin flyer plates can be properly accelerated and that there are predictive techniques available which are adequate to calculate the motion of the flyer plate. Recommendations are made for future study that must be undertaken to make the SASN flyer plate technique usable

  14. Quantitative imaging of the human upper airway: instrument design and clinical studies

    Science.gov (United States)

    Leigh, M. S.; Armstrong, J. J.; Paduch, A.; Sampson, D. D.; Walsh, J. H.; Hillman, D. R.; Eastwood, P. R.

    2006-08-01

    Imaging of the human upper airway is widely used in medicine, in both clinical practice and research. Common imaging modalities include video endoscopy, X-ray CT, and MRI. However, no current modality is both quantitative and safe to use for extended periods of time. Such a capability would be particularly valuable for sleep research, which is inherently reliant on long observation sessions. We have developed an instrument capable of quantitative imaging of the human upper airway, based on endoscopic optical coherence tomography. There are no dose limits for optical techniques, and the minimally invasive imaging probe is safe for use in overnight studies. We report on the design of the instrument and its use in preliminary clinical studies, and we present results from a range of initial experiments. The experiments show that the instrument is capable of imaging during sleep, and that it can record dynamic changes in airway size and shape. This information is useful for research into sleep disorders, and potentially for clinical diagnosis and therapies.

  15. Initial experience of Fag-PET/CT guided Imr of head-and-neck carcinoma

    International Nuclear Information System (INIS)

    Wang Dian; Schultz, Christopher J.; Jursinic, Paul A.; Bialkowski, Mirek; Zhu, X. Ronald; Brown, W. Douglas; Rand, Scott D.; Michel, Michelle A.; Campbell, Bruce H.; Wong, Stuart; Li, X. Allen; Wilson, J. Frank

    2006-01-01

    Purpose: The purpose of this study is to evaluate the impact of 18 F-fluorodeoxyglucose positron emission tomography (Fag-PET) fused with planning computed tomography (CT) on tumor localization, which guided intensity-modulated radiotherapy (Imr) of patients with head-and-neck carcinoma. Methods and Materials: From October 2002 through April 2005, we performed Fag-PET/CT guided Imr for 28 patients with head-and-neck carcinoma. Patients were immobilized with face masks that were attached with five fiducial markers. Fag-PET and planning CT scans were performed on the same flattop table in one session and were then fused. Target volumes and critical organs were contoured, and Imr plans were generated based on the fused images. Results: All 28 patients had abnormal increased uptake in Fag-PET/CT scans. PET/CT resulted in CT-based staging changes in 16 of 28 (57%) patients. PET/CT fusions were successfully performed and were found to be accurate with the use of the two commercial planning systems. Volume analysis revealed that the PET/CT-based gross target volumes (GTVs) were significantly different from those contoured from the CT scans alone in 14 of 16 patients. In addition, 16 of 28 patients who were followed for more than 6 months did not have any evidence of locoregional recurrence in the median time of 17 months. Conclusion: Fused images were found to be useful to delineate GTV required in IMRT planning. PET/CT should be considered for both initial staging and treatment planning in patients with head-and-neck carcinoma

  16. X-ray diagnostics in the laser-initiated fusion program

    International Nuclear Information System (INIS)

    Godwin, R.P.

    1975-08-01

    The high-density and high-temperature plasma conditions required for successful laser-initiated fusion make x-ray diagnostics a valuable tool in this exciting field. Measurements of the hard x-ray continuum emitted from laser targets provide insight into the complex laser-plasma coupling physics and the consequent energy transport through the bremsstrahlung signature of energetic electrons. X-ray techniques are important in the selection and assay of microballoon targets for current compression experiments. X-ray imaging experiments and diffraction spectroscopy of highly stripped atoms can provide information upon the symmetry, density and temperature of laser targets. Extremely high temporal and spatial resolution may be required for definitive diagnostic information on compressed targets. While laser-produced plasmas are interesting as possible intense x-ray sources and as a possible means of achieving x-ray lasing, those topics are outside the scope of this review. (auth)

  17. Active learning methods for interactive image retrieval.

    Science.gov (United States)

    Gosselin, Philippe Henri; Cord, Matthieu

    2008-07-01

    Active learning methods have been considered with increased interest in the statistical learning community. Initially developed within a classification framework, a lot of extensions are now being proposed to handle multimedia applications. This paper provides algorithms within a statistical framework to extend active learning for online content-based image retrieval (CBIR). The classification framework is presented with experiments to compare several powerful classification techniques in this information retrieval context. Focusing on interactive methods, active learning strategy is then described. The limitations of this approach for CBIR are emphasized before presenting our new active selection process RETIN. First, as any active method is sensitive to the boundary estimation between classes, the RETIN strategy carries out a boundary correction to make the retrieval process more robust. Second, the criterion of generalization error to optimize the active learning selection is modified to better represent the CBIR objective of database ranking. Third, a batch processing of images is proposed. Our strategy leads to a fast and efficient active learning scheme to retrieve sets of online images (query concept). Experiments on large databases show that the RETIN method performs well in comparison to several other active strategies.

  18. Bile Duct Anastomosis Supplied With Biodegradable Stent in Liver Transplantation: The Initial Experience.

    Science.gov (United States)

    Janousek, L; Maly, S; Oliverius, M; Kocik, M; Kucera, M; Fronek, J

    2016-12-01

    The most common biliary complications after orthotopic liver transplantation are bile leaks, anastomotic and intrahepatic strictures, stones, and ampullary dysfunction. These complications can occur in up to 10% to 30% of liver transplant recipients. Leaks occur early in the posttransplant period; the stricture formation typically graduates over time. Ten patients underwent transplantation in our preliminary study: 5 were randomized to the group with stent placement and 5 to the control group. We investigated the role of an absorbable biliary stent with the goal of proving patency of duct-to-duct biliary anastomosis. The stents are made of machine-knitted polydioxanone monofilaments. Our initial results show that duct-to-duct biliary reconstruction using an absorbable internal stent had good patency in all 5 patients. There were no signs of biliary leakage accompanying the anastomoses in any of the cases, and there was no stone formation observed after liver transplantation. The biliary stent was completely absorbed, with no adverse effects. Based on our initial experience and data, we concluded that biodegradable stents can be successfully and safely used in clinical practice. Further large prospective randomized studies are needed to estimate the efficacy of the bioabsorbable stents. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Computational Ghost Imaging for Remote Sensing

    Science.gov (United States)

    Erkmen, Baris I.

    2012-01-01

    This work relates to the generic problem of remote active imaging; that is, a source illuminates a target of interest and a receiver collects the scattered light off the target to obtain an image. Conventional imaging systems consist of an imaging lens and a high-resolution detector array [e.g., a CCD (charge coupled device) array] to register the image. However, conventional imaging systems for remote sensing require high-quality optics and need to support large detector arrays and associated electronics. This results in suboptimal size, weight, and power consumption. Computational ghost imaging (CGI) is a computational alternative to this traditional imaging concept that has a very simple receiver structure. In CGI, the transmitter illuminates the target with a modulated light source. A single-pixel (bucket) detector collects the scattered light. Then, via computation (i.e., postprocessing), the receiver can reconstruct the image using the knowledge of the modulation that was projected onto the target by the transmitter. This way, one can construct a very simple receiver that, in principle, requires no lens to image a target. Ghost imaging is a transverse imaging modality that has been receiving much attention owing to a rich interconnection of novel physical characteristics and novel signal processing algorithms suitable for active computational imaging. The original ghost imaging experiments consisted of two correlated optical beams traversing distinct paths and impinging on two spatially-separated photodetectors: one beam interacts with the target and then illuminates on a single-pixel (bucket) detector that provides no spatial resolution, whereas the other beam traverses an independent path and impinges on a high-resolution camera without any interaction with the target. The term ghost imaging was coined soon after the initial experiments were reported, to emphasize the fact that by cross-correlating two photocurrents, one generates an image of the target. In

  20. Asteroid Moon Micro-imager Experiment (amie) For Smart-1 Mission, Science Objectives and Devel- Opment Status.

    Science.gov (United States)

    Josset, J.-L.; Heather, D.; Dunkin, S.; Roussel, F.; Beauvivre, S.; Kraenhenbuehl, D.; Plancke, P.; Lange-Vin, Y.; Pinet, P.; Chevrel, S.; Cerroni, P.; de Sanctis, M.-C.; Dillelis, A.; Sodnik, Z.; Koschny, D.; Barucci, A.; Hofmann, B.; Josset, M.; Muinonen, K.; Pironnen, J.; Ehrenfreud, P.; Shkuratov, Y.; Shevchenko, V.

    The Asteroid Moon micro-Imager Experiment (AMIE), which will be on board the first ESA SMART-1 mission to the Moon (launch foreseen late 2002), is an imaging sys- tem with scientific, technical and public outreach oriented objectives. The science objectives are to imagine the Lunar South Pole (Aitken basin), permanent shadow areas (ice deposit), eternal light (crater rims), ancient Lunar Non- mare volcanism, local spectro-photometry and physical state of the lunar surface, and to map high latitudes regions (south) mainly at far side (Fig. 1). The technical objectives are to perform a laser-link experiment (detection of laser beam emitted by ESA Tenerife ground station), flight demonstration of new technologies, navigation aid (feasi- bility study), and on-board autonomy investigations. Figure 3: AMIE camera (light source and a photodiode to verify the stability of the incident flux. The optical system is com- posed of a lens to insure good focusing on the samples (focus with the camera is at distance > 100m) and a mirror to image downwards. The samples used were anorthosite from northern Finland, basalt from Antarctis, meteorites and other lunar analog materials. A spectralon panel has also been used to have flat fields references. The samples were imaged with dif- Figure 1: SMART-1 camera imaging the Moon (simulated view) ferent phase angles. Figure 4 shows images obtained with In order to have spectral information of the surface of the basalt and olivine samples, with different integration times Moon, the camera is equipped with a set of filters (Fig. 2), in order to have information in all areas. introduced between the CCD and the teleobjective. Bandpass-filter No Filter, 750 nm (1) AR coating (3) Bandpass-filter 915 nm (2) Longpass-filter 960 nm (4) Band- Band- Figure 4: Basalt and Olivine sample ­ entire image (left) and passfilter passfilter 915 nm 750 nm visible part () (6) (7) Bandpass- More than 150 images were acquired during this validation filter 847

  1. Simultaneous usage of pinhole and penumbral apertures for imaging small scale neutron sources from inertial confinement fusion experiments.

    Science.gov (United States)

    Guler, N; Volegov, P; Danly, C R; Grim, G P; Merrill, F E; Wilde, C H

    2012-10-01

    Inertial confinement fusion experiments at the National Ignition Facility are designed to understand the basic principles of creating self-sustaining fusion reactions by laser driven compression of deuterium-tritium (DT) filled cryogenic plastic capsules. The neutron imaging diagnostic provides information on the distribution of the central fusion reaction region and the surrounding DT fuel by observing neutron images in two different energy bands for primary (13-17 MeV) and down-scattered (6-12 MeV) neutrons. From this, the final shape and size of the compressed capsule can be estimated and the symmetry of the compression can be inferred. These experiments provide small sources with high yield neutron flux. An aperture design that includes an array of pinholes and penumbral apertures has provided the opportunity to image the same source with two different techniques. This allows for an evaluation of these different aperture designs and reconstruction algorithms.

  2. Application of velocity imaging and gradient-recalled echo in neuroimaging

    International Nuclear Information System (INIS)

    Boyko, O.B.; Pelc, N.J.; Shimakawa, A.

    1990-01-01

    This paper describes the initial clinical experience with imaging blood flow at 1.5 T by means of a phase-sensitive gradient refocused pulse sequence. A spin-echo flow-encoding technique was modified to a gradient recalled acquisition in a steady state sequence, producing a velocity imaging and gradient recalled echo (VIGRE) sequence (TR = 24 msec, TE = 13 msec, flip angle = 45 degrees, 24-cm field of view, 7 mm contiguous sections). Two views per phase-encoding step are acquired; one using the first-moment flow-compensation gradient waveform and the second having a (selectable) nonzero first moment. A phase subtraction image is obtained where the signal is dependent on the direction and velocity of flow. The sequence was done following routine spin-echo imaging in 35 patients

  3. The initial appearance of lung adenocarcinoma on computed tomography

    International Nuclear Information System (INIS)

    Saito, Haruhiro; Yamada, Kozo; Suzuki, Rie; Oshita, Fumihiro; Nakayama, Haruhiko; Mitsuda, Aki; Kameda, Youichi; Noda, Kazumasa

    2002-01-01

    The purpose of this study was to determine the initial appearance of lung adenocarcinoma on computed tomography and the appropriate follow-up duration. Retrospective review of 17 cases in which computed tomography (CT) of the chest was performed about 2 years prior to the diagnosis of lung cancer. The diagnosis was confirmed by surgical resection in all cases. The lung cancers were divided into four types based on their appearance on the initial CT: ground-glass opacity (GGO)-like images in which the lesion appeared as a faint opacity, BLA (bubble-like appearance) image, in which the lesion resembled a focal collection of air, a small solitary nodule, and a scar-like image. Vascular involvement, air-bronchogram, and pleural indentation were all more prominent during a serial scan obtained just prior to surgery than on the initial scan. An increase in vascular involvement occurred prior to the other changes. High attenuation areas appeared in the GGO-like lesions prior to an increase in the size of the lesion. The growth pattern was classified as slow growing, rapidly growing, and initially slow growing with accelerated growth. The doubling time was similar in lesions with the same appearance. This information can be used to guide follow-up of images suspected of lung cancer. The appropriate follow-up duration is estimated from 6 to 12 months for GGO and BLA-like images, and from 2 to 3 months for small solitary nodules. The biological behavior of lung cancer is reflected in their initial appearance on CT. (author)

  4. An Optimized Method for Terrain Reconstruction Based on Descent Images

    Directory of Open Access Journals (Sweden)

    Xu Xinchao

    2016-02-01

    Full Text Available An optimization method is proposed to perform high-accuracy terrain reconstruction of the landing area of Chang’e III. First, feature matching is conducted using geometric model constraints. Then, the initial terrain is obtained and the initial normal vector of each point is solved on the basis of the initial terrain. By changing the vector around the initial normal vector in small steps a set of new vectors is obtained. By combining these vectors with the direction of light and camera, the functions are set up on the basis of a surface reflection model. Then, a series of gray values is derived by solving the equations. The new optimized vector is recorded when the obtained gray value is closest to the corresponding pixel. Finally, the optimized terrain is obtained after iteration of the vector field. Experiments were conducted using the laboratory images and descent images of Chang’e III. The results showed that the performance of the proposed method was better than that of the classical feature matching method. It can provide a reference for terrain reconstruction of the landing area in subsequent moon exploration missions.

  5. Initial experience gained with the balance-group system of the Swiss power supply legislation

    International Nuclear Information System (INIS)

    Waldner, M.; Rechsteiner, S.

    2010-01-01

    This article takes a look at the initial experience gained with the Swiss balance-group system. This system was introduced within the framework of Swiss power supply legislation (StromVG - Stromversorgungsgesetz). The balance-group system was considered to be an essential precondition for the implementation of an energy trading business in a liberalised power market. The associated rights and responsibilities and the economic risks involved are discussed in detail. The partners and structures involved in such a balance-group are looked at and basic models for the associated contracts are examined. The relationship between balance-groups and the national power grid Swissgrid are discussed

  6. Transient debris freezing and potential wall melting during a severe reactivity initiated accident experiment

    International Nuclear Information System (INIS)

    El-Genk, M.S.; Moore, R.L.

    1981-01-01

    It is important to light water reactor (LWR) safety analysis to understand the transient freezing of molten core debris on cold structures following a hypothetical core meltdown accident. The purpose of this paper is to (a) present the results of a severe reactivity initiated accident (RIA) in-pile experiment with regard to molten debris distribution and freezing following test fuel rod failure, (b) analyze the transient freezing of molten debris (primarily a mixture of UO/sub 2/ fuel and Zircaloy cladding) deposited on the inner surface of the test shroud wall upon rod failure, and (c) assess the potential for wall melting upon being contacted by the molten debris. 26 refs

  7. Initial image interpretation of appendicular skeletal radiographs: A comparison between nurses and radiographers

    International Nuclear Information System (INIS)

    Piper, Keith J.; Paterson, Audrey

    2009-01-01

    , although differences in performance between the two groups remained, with the radiographer group achieving a better overall performance than the nurse group. As patients in MIUs and A/E receive treatment based on the initial interpretation of their imaging investigations by either nurses or radiographers, the improvement after training is encouraging but the difference in the overall performance is less so. More work is required to evaluate the performance of radiographers and nurses undertaking initial image interpretation as part of their normal practice

  8. Cross-validated detection of crack initiation in aerospace materials

    Science.gov (United States)

    Vanniamparambil, Prashanth A.; Cuadra, Jefferson; Guclu, Utku; Bartoli, Ivan; Kontsos, Antonios

    2014-03-01

    A cross-validated nondestructive evaluation approach was employed to in situ detect the onset of damage in an Aluminum alloy compact tension specimen. The approach consisted of the coordinated use primarily the acoustic emission, combined with the infrared thermography and digital image correlation methods. Both tensile loads were applied and the specimen was continuously monitored using the nondestructive approach. Crack initiation was witnessed visually and was confirmed by the characteristic load drop accompanying the ductile fracture process. The full field deformation map provided by the nondestructive approach validated the formation of a pronounced plasticity zone near the crack tip. At the time of crack initiation, a burst in the temperature field ahead of the crack tip as well as a sudden increase of the acoustic recordings were observed. Although such experiments have been attempted and reported before in the literature, the presented approach provides for the first time a cross-validated nondestructive dataset that can be used for quantitative analyses of the crack initiation information content. It further allows future development of automated procedures for real-time identification of damage precursors including the rarely explored crack incubation stage in fatigue conditions.

  9. Initial Experience with ABO-incompatible Live Donor Renal Transplantation

    Directory of Open Access Journals (Sweden)

    Meng-Kun Tsai

    2006-01-01

    Full Text Available The serious shortage of cadaveric organs has prompted the development of ABO-incompatible live donor renal transplantation. We report our experience of the initial two live donor ABO incompatible renal transplants at our hospital. The first patient was a 55-year-old type A female who received a kidney from her AB type husband. The second patient was a 27-year-old type O male who received renal transplantation from his type A father. Preconditioning immunosuppressive therapy in the two patients with tacrolimus, mycophenolate mofetil and methylprednisolone was started 7 days before transplantation. During the period of preconditioning, double filtration plasmapheresis (DFPP was employed to remove anti-A and -B antibodies. Laparoscopic splenectomy and renal transplantation were performed after the anti-donor ABO antibodies were reduced to a titer of 1:4. Rituximab, a humanized monoclonal anti-CD20 antibody, was administered to the second patient due to a rebound in the anti-A antibody titer during the preconditioning period. Under a tacrolimus-based immunosuppressive regimen, both patients recovered very well without any evidence of rejection. Serum creatinine levels were 1.0 and 1.4 mg/dL at 6 and 3 months after transplantation, respectively. These cases illustrate that with new immunosuppressive agents, DFPP and splenectomy, ABO-incompatible renal transplantation can be successfully conducted in end-stage renal disease patients whose only available live donors are blood group incompatible.

  10. Mammography with and without radiolucent positioning sheets: Comparison of projected breast area, pain experience, radiation dose and technical image quality

    NARCIS (Netherlands)

    Timmers, Janine; ten Voorde, Marloes; van Engen, Ruben E.; van Landsveld-Verhoeven, Cary; Pijnappel, Ruud; Droogh-de Greve, Kitty; den Heeten, Gerard J.; Broeders, Mireille J. M.

    2015-01-01

    To compare projected breast area, image quality, pain experience and radiation dose between mammography performed with and without radiolucent positioning sheets. 184 women screened in the Dutch breast screening programme (May-June 2012) provided written informed consent to have one additional image

  11. Automatic initialization and quality control of large-scale cardiac MRI segmentations.

    Science.gov (United States)

    Albà, Xènia; Lekadir, Karim; Pereañez, Marco; Medrano-Gracia, Pau; Young, Alistair A; Frangi, Alejandro F

    2018-01-01

    Continuous advances in imaging technologies enable ever more comprehensive phenotyping of human anatomy and physiology. Concomitant reduction of imaging costs has resulted in widespread use of imaging in large clinical trials and population imaging studies. Magnetic Resonance Imaging (MRI), in particular, offers one-stop-shop multidimensional biomarkers of cardiovascular physiology and pathology. A wide range of analysis methods offer sophisticated cardiac image assessment and quantification for clinical and research studies. However, most methods have only been evaluated on relatively small databases often not accessible for open and fair benchmarking. Consequently, published performance indices are not directly comparable across studies and their translation and scalability to large clinical trials or population imaging cohorts is uncertain. Most existing techniques still rely on considerable manual intervention for the initialization and quality control of the segmentation process, becoming prohibitive when dealing with thousands of images. The contributions of this paper are three-fold. First, we propose a fully automatic method for initializing cardiac MRI segmentation, by using image features and random forests regression to predict an initial position of the heart and key anatomical landmarks in an MRI volume. In processing a full imaging database, the technique predicts the optimal corrective displacements and positions in relation to the initial rough intersections of the long and short axis images. Second, we introduce for the first time a quality control measure capable of identifying incorrect cardiac segmentations with no visual assessment. The method uses statistical, pattern and fractal descriptors in a random forest classifier to detect failures to be corrected or removed from subsequent statistical analysis. Finally, we validate these new techniques within a full pipeline for cardiac segmentation applicable to large-scale cardiac MRI databases. The

  12. Fast exposure time decision in multi-exposure HDR imaging

    Science.gov (United States)

    Piao, Yongjie; Jin, Guang

    2012-10-01

    Currently available imaging and display system exists the problem of insufficient dynamic range, and the system cannot restore all the information for an high dynamic range (HDR) scene. The number of low dynamic range(LDR) image samples and fastness of exposure time decision impacts the real-time performance of the system dramatically. In order to realize a real-time HDR video acquisition system, this paper proposed a fast and robust method for exposure time selection in under and over exposure area which is based on system response function. The method utilized the monotony of the imaging system. According to this characteristic the exposure time is adjusted to an initial value to make the median value of the image equals to the middle value of the system output range; then adjust the exposure time to make the pixel value on two sides of histogram be the middle value of the system output range. Thus three low dynamic range images are acquired. Experiments show that the proposed method for adjusting the initial exposure time can converge in two iterations which is more fast and stable than average gray control method. As to the exposure time adjusting in under and over exposed area, the proposed method can use the dynamic range of the system more efficiently than fixed exposure time method.

  13. Endoscopic endonasal transsphenoidal surgery using the iArmS operation support robot: initial experience in 43 patients.

    Science.gov (United States)

    Ogiwara, Toshihiro; Goto, Tetsuya; Nagm, Alhusain; Hongo, Kazuhiro

    2017-05-01

    Objective The intelligent arm-support system, iArmS, which follows the surgeon's arm and automatically fixes it at an adequate position, was developed as an operation support robot. iArmS was designed to support the surgeon's forearm to prevent hand trembling and to alleviate fatigue during surgery with a microscope. In this study, the authors report on application of this robotic device to endoscopic endonasal transsphenoidal surgery (ETSS) and evaluate their initial experiences. Methods The study population consisted of 43 patients: 29 with pituitary adenoma, 3 with meningioma, 3 with Rathke's cleft cyst, 2 with craniopharyngioma, 2 with chordoma, and 4 with other conditions. All patients underwent surgery via the endonasal transsphenoidal approach using a rigid endoscope. During the nasal and sphenoid phases, iArmS was used to support the surgeon's nondominant arm, which held the endoscope. The details of the iArmS and clinical results were collected. Results iArmS followed the surgeon's arm movement automatically. It reduced the surgeon's fatigue and stabilized the surgeon's hand during ETSS. Shaking of the video image decreased due to the steadying of the surgeon's scope-holding hand with iArmS. There were no complications related to use of the device. Conclusions The intelligent armrest, iArmS, seems to be safe and effective during ETSS. iArmS is helpful for improving the precision and safety not only for microscopic neurosurgery, but also for ETSS. Ongoing advances in robotics ensure the continued evolution of neurosurgery.

  14. Experience – Information – Image: A Historiography of Unfolding. Arab Cinema as Example

    Directory of Open Access Journals (Sweden)

    Laura U. Marks

    2011-04-01

    Many artworks can be illuminated by this process. My examples will be drawn from contemporary Arab cinema. In the heavily politicized Arab milieu, the Image world is constructed as a selective unfolding of only those aspects of Experience that are deemed to be useful or profitable. Some Arab filmmakers, rather than deconstruct the resulting ideological images, prefer to carry out their own unfoldings:  explicating hitherto latent events, knowledges, and sensations. Thus what official history deems merely personal, absurd, micro-events, or no events at all, becomes the stuff of a rich alternative historiography. This process characterizes the work of, among others, Joana Hadjithomas and Khalil Joreige, Nisrine Khodr, Mohammed Soueid, and Akram Zaatari (Lebanon, Azza El-Hassan, Elia Suleiman, and Sobhi Al-Zobaidi (Palestine, and Mohamad Khan (Egypt.

  15. MR imaging of recent non-traumatic intracranial hemorrhage: early experience at 3 T

    International Nuclear Information System (INIS)

    Griffiths, Paul D.; Wilkinson, Iain D.

    2006-01-01

    Magnetic resonance imaging (MRI) using 3.0 T scanners in the clinical environment is in its infancy and is only available at a limited number of sites worldwide. There is great interest amongst radiologists about the perceived benefits of clinical imaging at 3.0 T; however, it remains to be seen whether the theoretical advantages will bring real gains. MRI in patients with non-traumatic intracranial hemorrhage (ICH) is difficult, yet, these patients benefit from non-invasive angiography. Conventional catheter angiography (CCA) remains the reference standard for excluding/confirming the presence of intracranial vascular abnormalities, but MR angiography at 3.0 T may offer opportunities for significant changes in patient management. We present our experiences of using 3.0 T MR angiography in 27 patients with acute or early subacute ICH. (orig.)

  16. Percutaneous Cryotherapy of Vascular Malformation: Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Cornelis, F., E-mail: francoiscornelis@hotmail.com [Institut Bergonie, Department of Radiology (France); Neuville, A. [Institut Bergonie, Department of Pathology (France); Labreze, C. [Pellegrin Hospital, Department of Pediatric Dermatology (France); Kind, M. [Institut Bergonie, Department of Radiology (France); Bui, B. [Institut Bergonie, Department of Oncology (France); Midy, D. [Pellegrin Hospital, Department of Vascular Surgery (France); Palussiere, J. [Institut Bergonie, Department of Radiology (France); Grenier, N. [Pellegrin Hospital, Department of Radiology (France)

    2013-06-15

    The present report describes a case of percutaneous cryotherapy in a 36-year-old woman with a large and painful pectoral venous malformation. Cryoablation was performed in a single session for this 9-cm mass with 24 h hospitalisation. At 2- and 6-month follow-up, the pain had completely disappeared, and magnetic resonance imaging demonstrated a significant decrease in size. Percutaneous cryoablation shows promise as a feasible and apparently safe method for local control in patients with symptomatic venous vascular malformations.

  17. Percutaneous Cryotherapy of Vascular Malformation: Initial Experience

    International Nuclear Information System (INIS)

    Cornelis, F.; Neuville, A.; Labrèze, C.; Kind, M.; Bui, B.; Midy, D.; Palussière, J.; Grenier, N.

    2013-01-01

    The present report describes a case of percutaneous cryotherapy in a 36-year-old woman with a large and painful pectoral venous malformation. Cryoablation was performed in a single session for this 9-cm mass with 24 h hospitalisation. At 2- and 6-month follow-up, the pain had completely disappeared, and magnetic resonance imaging demonstrated a significant decrease in size. Percutaneous cryoablation shows promise as a feasible and apparently safe method for local control in patients with symptomatic venous vascular malformations.

  18. Motion tracking to enable pre-surgical margin mapping in basal cell carcinoma using optical imaging modalities: initial feasibility study using optical coherence tomography

    Science.gov (United States)

    Duffy, M.; Richardson, T. J.; Craythorne, E.; Mallipeddi, R.; Coleman, A. J.

    2014-02-01

    A system has been developed to assess the feasibility of using motion tracking to enable pre-surgical margin mapping of basal cell carcinoma (BCC) in the clinic using optical coherence tomography (OCT). This system consists of a commercial OCT imaging system (the VivoSight 1500, MDL Ltd., Orpington, UK), which has been adapted to incorporate a webcam and a single-sensor electromagnetic positional tracking module (the Flock of Birds, Ascension Technology Corp, Vermont, USA). A supporting software interface has also been developed which allows positional data to be captured and projected onto a 2D dermoscopic image in real-time. Initial results using a stationary test phantom are encouraging, with maximum errors in the projected map in the order of 1-2mm. Initial clinical results were poor due to motion artefact, despite attempts to stabilise the patient. However, the authors present several suggested modifications that are expected to reduce the effects of motion artefact and improve the overall accuracy and clinical usability of the system.

  19. Breast Imaging Utilizing Dedicated Gamma Camera and (99m)Tc-MIBI: Experience at the Tel Aviv Medical Center and Review of the Literature Breast Imaging.

    Science.gov (United States)

    Even-Sapir, Einat; Golan, Orit; Menes, Tehillah; Weinstein, Yuliana; Lerman, Hedva

    2016-07-01

    The scope of the current article is the clinical role of gamma cameras dedicated for breast imaging and (99m)Tc-MIBI tumor-seeking tracer, as both a screening modality among a healthy population and as a diagnostic modality in patients with breast cancer. Such cameras are now commercially available. The technology utilizing a camera composed of a NaI (Tl) detector is termed breast-specific gamma imaging. The technology of dual-headed camera composed of semiconductor cadmium zinc telluride detectors that directly converts gamma-ray energy into electronic signals is termed molecular breast imaging. Molecular breast imaging system has been installed at the Department of Nuclear medicine at the Tel Aviv Sourasky Medical Center, Tel Aviv in 2009. The article reviews the literature well as our own experience. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization

    International Nuclear Information System (INIS)

    Zbijewski, W.; De Jean, P.; Prakash, P.; Ding, Y.; Stayman, J. W.; Packard, N.; Senn, R.; Yang, D.; Yorkston, J.; Machado, A.; Carrino, J. A.; Siewerdsen, J. H.

    2011-01-01

    Purpose: This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopaedic surgery, and rheumatology. Methods: The scanner design incorporated a host of clinical requirements (e.g., ability to scan the weight-bearing knee in a natural stance) and was guided by theoretical and experimental analysis of image quality and dose. Such criteria identified the following basic scanner components and system configuration: a flat-panel detector (FPD, Varian 3030+, 0.194 mm pixels); and a low-power, fixed anode x-ray source with 0.5 mm focal spot (SourceRay XRS-125-7K-P, 0.875 kW) mounted on a retractable C-arm allowing for two scanning orientations with the capability for side entry, viz. a standing configuration for imaging of weight-bearing lower extremities and a sitting configuration for imaging of tensioned upper extremity and unloaded lower extremity. Theoretical modeling employed cascaded systems analysis of modulation transfer function (MTF) and detective quantum efficiency (DQE) computed as a function of system geometry, kVp and filtration, dose, source power, etc. Physical experimentation utilized an imaging bench simulating the scanner geometry for verification of theoretical results and investigation of other factors, such as antiscatter grid selection and 3D image quality in phantom and cadaver, including qualitative comparison to conventional CT. Results: Theoretical modeling and benchtop experimentation confirmed the basic suitability of the FPD and x-ray source mentioned above. Clinical requirements combined with analysis of MTF and DQE yielded the following system geometry: a ∼55 cm source-to-detector distance; 1.3 magnification; a 20